WorldWideScience

Sample records for pulmonary perfusion imaging

  1. Perfusion abnormalities in congenital and neoplastic pulmonary disease: comparison of MR perfusion and multislice CT imaging

    International Nuclear Information System (INIS)

    Boll, Daniel T.; Lewin, Jonathan S.; Young, Philip; Gilkeson, Robert C.; Siwik, Ernest S.

    2005-01-01

    The aim of this work was to assess magnetic resonance (MR) perfusion patterns of chronic, nonembolic pulmonary diseases of congenital and neoplastic origin and to compare the findings with results obtained with pulmonary, contrast-enhanced multislice computed tomography (CT) imaging to prove that congenital and neoplastic pulmonary conditions require MR imaging over the pulmonary perfusion cycle to successfully and directly detect changes in lung perfusion patterns. Twenty-five patients underwent concurrent CT and MR evaluation of chronic pulmonary diseases of congenital (n=15) or neoplastic (n=10) origin. Analysis of MR perfusion and contrast-enhanced CT datasets was realized by defining pulmonary and vascular regions of interest in corresponding positions. MR perfusion calculated time-to-peak enhancement, maximal enhancement and the area under the perfusion curve. CT datasets provided pulmonary signal-to-noise ratio measurements. Vessel centerlines of bronchial arteries were determined. Underlying perfusion type, such as pulmonary arterial or systemic arterial supply, as well as regions with significant variations in perfusion were determined statistically. Analysis of the pulmonary perfusion pattern detected pulmonary arterial supply in 19 patients; six patients showed systemic arterial supply. In pulmonary arterial perfusion, MR and multislice CT imaging consistently detected the perfusion type and regions with altered perfusion patterns. In bronchial arterial supply, MR perfusion and CT imaging showed significant perfusion differences. Patients with bronchial arterial supply had bronchial arteries ranging from 2.0 to 3.6 mm compared with submillimeter diameters in pulmonary arterial perfusion. Dynamic MR imaging of congenital and neoplastic pulmonary conditions allowed characterization of the pulmonary perfusion type. CT imaging suggested the presence of systemic arterial perfusion by visualizing hypertrophied bronchial arteries. (orig.)

  2. Enhanced magnetic resonance pulmonary perfusion imaging in diagnosing pulmonary embolism: preliminary investigation

    International Nuclear Information System (INIS)

    Huang Xiaoyong; Du Jing; Zhang Zhaoqi; Guo Xi; Yan Zixu; Jiang Hong; Wang Wei

    2005-01-01

    Objective: This study was designed to investigate the sensitivity and specificity of magnetic resonance pulmonary perfusion imaging (MRPP) in diagnosing pulmonary embolism (PE) compared with enhanced magnetic resonance pulmonary angiography (MRPA) and pulmonary radionuclide perfusion imaging. Methods: Fourteen patients were definitely diagnosed as PE, whose ages were from 19 to 71 years old and mean 45.5 ± 19.8 years old. All patients under went MRPA and MRPP and 3 patients were examined again after thrombolytic treatment. Five patients underwent pulmonary radionuclide perfusion imaging. Setting ROI in top, middle, bottom of lung area and abnormal area respectively, we detected signal intensity and time-signal curve to obtain the transformation rate of signal (TROS) during perfusion peak value. Results: In 14 pulmonary embolism patients, MRPA found 62 branches of pulmonary artery obstruction. Fifty-five abnormal pulmonary perfusion zones were found by MRPP, and the above results were very alike. The coincidence was 88.71%. In 14 cases, MRPP could show 25 subsegments lesion below segments. In 5 patients who had both results Of MRPP and ECT at the same time. MRPP shows 33 perfusion defect zones and 37 segments were found by ECT, the sensitivity was 89.19%. After thrombolytic treatment, both the status of the affected pulmonary artery improved markedly and perfusion defect zones reduced obviously in 3 cases by MRPP and MRPA. TROS in normal perfusion zones perfusion defect zones and low perfusion zones had significant difference (t=22.882, P<0.01). Conclusion: Contrast enhanced MR pulmonary perfusion can show both perfusion defect zones and low perfusion zones in pulmonary embolism. Time-signal curve can show the period of maximum no perfusion zones in pulmonary artery embolism zones. And the amplitude of fluctuation is small with miminum TROS. MRPP has significant values especially in showing pulmonary artery embolism in segments and subsegments. Using both MRPP and

  3. A comparative analysis of pulmonary ventilation-perfusion imaging with pulmonary angiography in the diagnosis of pulmonary embolism

    International Nuclear Information System (INIS)

    Wang Jincheng; Mi Hongzhi; Wang Qian; Zhang Weijun; Lu Biao; Yang Hao; Ding Jian; Lu Yao

    2001-01-01

    Objective: To assess the value of ventilation-perfusion imaging in the diagnosis of pulmonary embolism (PE). Methods: Thirty consecutive patients with clinically suspected pulmonary embolism were studied, male: female 15:15, mean age was (36.2 +- 13.9) years. The chest radiograms were obtained in all 30 patients. All patients underwent radionuclide ventilation-perfusion imaging and pulmonary angiography. Results: Of the 30 patients, 22 with lobe, multiple segment or multi-subsegment perfusion defects and normal or nearly normal ventilation images were reported as PE. 20 of them were confirmed to be with PE by pulmonary angiography, 2 patients were not confirmed. Eight of 30 patients with multiple perfusion defects, ventilative abnormalities were reported as non-PE and the diagnoses were confirmed by pulmonary angiography. The sensitivity, specificity and accuracy of diagnosis of PE by ventilation-perfusion imaging was 100%, 80.0% and 93.3% respectively. Conclusions: (1) Ventilation-perfusion imaging is one of the most valuable methods in the diagnosis of PE. (2) The results suggest that pulmonary embolism can be diagnosed non-invasively in most patients on the basis of clinical manifestation, chest radiograms and ventilation-perfusion imaging findings. (3) Pulmonary angiography is required while clinical manifestation and ventilation-perfusion imaging findings are discordant with each other

  4. Pulmonary ventilation and perfusion imaging with dual-energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Thieme, Sven F. [Klinikum Grosshadern, Department of Clinical Radiology, Ludwig Maximilians University, Muenchen (Germany); Klinikum Grosshadern, Institut fuer Klinische Radiologie, LMU Muenchen, Muenchen (Germany); Hoegl, Sandra; Fisahn, Juergen; Irlbeck, Michael [Klinikum Grosshadern, Department of Anesthesiology, Ludwig Maximilians University, Muenchen (Germany); Nikolaou, Konstantin; Maxien, Daniel; Reiser, Maximilian F.; Becker, Christoph R.; Johnson, Thorsten R.C. [Klinikum Grosshadern, Department of Clinical Radiology, Ludwig Maximilians University, Muenchen (Germany)

    2010-12-15

    To evaluate the feasibility of dual-energy CT (DECT) ventilation imaging in combination with DE perfusion mapping for a comprehensive assessment of ventilation, perfusion, morphology and structure of the pulmonary parenchyma. Two dual-energy CT acquisitions for xenon-enhanced ventilation and iodine-enhanced perfusion mapping were performed in patients under artificial respiration. Parenchymal xenon and iodine distribution were mapped and correlated with structural or vascular abnormalities. In all datasets, image quality was sufficient for a comprehensive image reading of the pulmonary CTA images, lung window images and pulmonary functional parameter maps and led to expedient results in each patient. With dual-source CT systems, DECT of the lung with iodine or xenon administration is technically feasible and makes it possible to depict the regional iodine or xenon distribution representing the local perfusion and ventilation. (orig.)

  5. Dynamic Chest Image Analysis: Model-Based Perfusion Analysis in Dynamic Pulmonary Imaging

    Directory of Open Access Journals (Sweden)

    Kiuru Aaro

    2003-01-01

    Full Text Available The "Dynamic Chest Image Analysis" project aims to develop model-based computer analysis and visualization methods for showing focal and general abnormalities of lung ventilation and perfusion based on a sequence of digital chest fluoroscopy frames collected with the dynamic pulmonary imaging technique. We have proposed and evaluated a multiresolutional method with an explicit ventilation model for ventilation analysis. This paper presents a new model-based method for pulmonary perfusion analysis. According to perfusion properties, we first devise a novel mathematical function to form a perfusion model. A simple yet accurate approach is further introduced to extract cardiac systolic and diastolic phases from the heart, so that this cardiac information may be utilized to accelerate the perfusion analysis and improve its sensitivity in detecting pulmonary perfusion abnormalities. This makes perfusion analysis not only fast but also robust in computation; consequently, perfusion analysis becomes computationally feasible without using contrast media. Our clinical case studies with 52 patients show that this technique is effective for pulmonary embolism even without using contrast media, demonstrating consistent correlations with computed tomography (CT and nuclear medicine (NM studies. This fluoroscopical examination takes only about 2 seconds for perfusion study with only low radiation dose to patient, involving no preparation, no radioactive isotopes, and no contrast media.

  6. The clinical value of pulmonary perfusion imaging complicated with pulmonary embolism in children of nephrotic syndrome

    International Nuclear Information System (INIS)

    Lin Jun; Chen Ning; Miao Weibing; Peng Jiequan; Jiang Zhihong; Wu Jing

    2001-01-01

    To investigate the clinical features of complicated with pulmonary embolism nephrotic syndrome in children. 99m Tc-MAA pulmonary perfusion imaging was performed on 30 nephrotic syndrome in children with elevated plasma D-dimer. Results shown that 14 of 30 patients were found to have pulmonary embolism (46.7%). Pulmonary perfusion imaging showed an involvement of 1 pulmonary segment in 3 cases, 2 segments in 2 cases and over 3 segments in other 9 cases. Among them, there were 7 segments involved in one case. After two weeks of heparin anti-coagulative therapy, most cases showed a recovery. The result of this study suggested that pulmonary embolism is a common complication of nephrotic syndrome. Pulmonary perfusion imaging is simple, effective and accurate method for the diagnosis of pulmonary embolism, and it also can help to assess the value of clinical therapy

  7. CT perfusion imaging in response assessment of pulmonary metastases undergoing stereotactic ablative radiotherapy

    International Nuclear Information System (INIS)

    Sawyer, Brooke; Pun, Emma; Tay, Huilee; Kron, Tomas; Bressel, Mathias; Ball, David; Siva, Shankar; Samuel, Michael

    2015-01-01

    Stereotactic ablative body radiotherapy (SABR) is an emerging treatment technique for pulmonary metastases in which conventional Response Evaluation Criteria in Solid Tumours (RECIST) may be inadequate. This study aims to assess the utility of CT perfusion imaging in response assessment of pulmonary metastases after SABR. In this ethics board-approved prospective study, 11 patients underwent a 26-Gy single fraction of SABR to pulmonary metastases. CT perfusion imaging occurred prior to and at 14 and 70 days post-SABR. Blood flow (mL/100 mL/min), blood volume (mL/100 mL), time to peak (seconds) and surface permeability (mL/100 mL/min), perfusion parameters of pulmonary metastases undergoing SABR, were independently assessed by two radiologists. Inter-observer variability was analysed. CT perfusion results were analysed for early response assessment comparing day 14 with baseline scans and for late response by comparing day 70 with baseline scans. The largest diameter of the pulmonary metastases undergoing SABR was recorded. Ten patients completed all three scans and one patient had baseline and early response assessment CT perfusion scans only. There was strong level of inter-observer agreement of CT perfusion interpretation with a median intraclass coefficient of 0.87 (range 0.20–0.98). Changes in all four perfusion parameters and tumour sizes were not statistically significant. CT perfusion imaging of pulmonary metastases is a highly reproducible imaging technique that may provide additional response assessment information above that of conventional RECIST, and it warrants further study in a larger cohort of patients undergoing SABR.

  8. Assessment of anatomic relation between pulmonary perfusion and morphology in pulmonary emphysema with breath-hold SPECT-CT fusion images

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Kawakami, Yasuhiko; Iwanaga, Hideyuki; Hayashi, Noriko; Seto, Akiko; Matsunaga, Naofumi

    2008-01-01

    Anatomic relation between pulmonary perfusion and morphology in pulmonary emphysema was assessed on deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images. Subjects were 38 patients with pulmonary emphysema and 11 non-smoker controls, who successfully underwent DIBrH and non-BrH perfusion SPECT using a dual-headed SPECT system during the period between January 2004 and June 2006. DIBrH SPECT was three-dimensionally co-registered with DIBrH CT to comprehend the relationship between lung perfusion defects and CT low attenuation areas (LAA). By comparing the appearance of lung perfusion on DIBrH with non-BrH SPECT, the correlation with the rate constant for the alveolar-capillary transfer of carbon monoxide (DLCO/VA) was compared between perfusion abnormalities on these SPECTs and LAA on CT. DIBrH SPECT provided fairly uniform perfusion in controls, but significantly enhanced perfusion heterogeneity when compared with non-BrH SPECT in pulmonary emphysema patients (P<0.001). The reliable DIBrH SPECT-CT fusion images confirmed more extended perfusion defects than LAA on CT in majority (73%) of patients. Perfusion abnormalities on DIBrH SPECT were more closely correlated with DLCO/VA than LAA on CT (P<0.05). DIBrH SPECT identifies affected lungs with perfusion abnormality better than does non-BrH SPECT in pulmonary emphysema. DIBrH SPECT-CT fusion images are useful for more accurately localizing affected lungs than morphologic CT alone in this disease. (author)

  9. [MRI methods for pulmonary ventilation and perfusion imaging].

    Science.gov (United States)

    Sommer, G; Bauman, G

    2016-02-01

    Separate assessment of respiratory mechanics, gas exchange and pulmonary circulation is essential for the diagnosis and therapy of pulmonary diseases. Due to the global character of the information obtained clinical lung function tests are often not sufficiently specific in the differential diagnosis or have a limited sensitivity in the detection of early pathological changes. The standard procedures of pulmonary imaging are computed tomography (CT) for depiction of the morphology as well as perfusion/ventilation scintigraphy and single photon emission computed tomography (SPECT) for functional assessment. Magnetic resonance imaging (MRI) with hyperpolarized gases, O2-enhanced MRI, MRI with fluorinated gases and Fourier decomposition MRI (FD-MRI) are available for assessment of pulmonary ventilation. For assessment of pulmonary perfusion dynamic contrast-enhanced MRI (DCE-MRI), arterial spin labeling (ASL) and FD-MRI can be used. Imaging provides a more precise insight into the pathophysiology of pulmonary function on a regional level. The advantages of MRI are a lack of ionizing radiation, which allows a protective acquisition of dynamic data as well as the high number of available contrasts and therefore accessible lung function parameters. Sufficient clinical data exist only for certain applications of DCE-MRI. For the other techniques, only feasibility studies and case series of different sizes are available. The clinical applicability of hyperpolarized gases is limited for technical reasons. The clinical application of the techniques described, except for DCE-MRI, should be restricted to scientific studies.

  10. MRI methods for pulmonary ventilation and perfusion imaging

    International Nuclear Information System (INIS)

    Sommer, G.; Bauman, G.

    2016-01-01

    Separate assessment of respiratory mechanics, gas exchange and pulmonary circulation is essential for the diagnosis and therapy of pulmonary diseases. Due to the global character of the information obtained clinical lung function tests are often not sufficiently specific in the differential diagnosis or have a limited sensitivity in the detection of early pathological changes. The standard procedures of pulmonary imaging are computed tomography (CT) for depiction of the morphology as well as perfusion/ventilation scintigraphy and single photon emission computed tomography (SPECT) for functional assessment. Magnetic resonance imaging (MRI) with hyperpolarized gases, O 2 -enhanced MRI, MRI with fluorinated gases and Fourier decomposition MRI (FD-MRI) are available for assessment of pulmonary ventilation. For assessment of pulmonary perfusion dynamic contrast-enhanced MRI (DCE-MRI), arterial spin labeling (ASL) and FD-MRI can be used. Imaging provides a more precise insight into the pathophysiology of pulmonary function on a regional level. The advantages of MRI are a lack of ionizing radiation, which allows a protective acquisition of dynamic data as well as the high number of available contrasts and therefore accessible lung function parameters. Sufficient clinical data exist only for certain applications of DCE-MRI. For the other techniques, only feasibility studies and case series of different sizes are available. The clinical applicability of hyperpolarized gases is limited for technical reasons. The clinical application of the techniques described, except for DCE-MRI, should be restricted to scientific studies. (orig.) [de

  11. The feasibility and accuracy of enhanced MR pulmonary perfusion imaging in evaluating therapeutic effect of pulmonary embolism

    International Nuclear Information System (INIS)

    Wang Nana; Lv Biao; Zhao Zhaoqi; Huang Xiaoyong; Lu Dongxu; Mi Hongzhi; Yu Weiyong

    2010-01-01

    Objective: To investigate the feasibility and accuracy of enhanced magnetic resonance pulmonary perfusion imaging (MRPP) in the diagnosis and follow-up of pulmonary embolism (PE). Methods: Sixty patients suspected of PE underwent MRPP. Twenty-seven patients also underwent radionuclide perfusion imaging. 22 patients repeated MRPP examination after 3 day to 1 month antieoagulation or thrombolytic therapy. The feasibility and accuracy of MRPP in the diagnosis and follow-up of PE were evaluated according to the transformation rate of signal (TROS), time-signal curve and some parameters of main pulmonary artery (such as peak value of flow, mean flow velocity and flow rate). The t test and rank sum test were used for the statistics. Results: MRPP showed a high agreement with radionuclide perfusion imaging. TROS was (2.86 ± 2.48) vs(6.72 ± 2.54) (t=3.370, P 0.05). Conclusion: MRPP shows a high agreement with radionuclide perfusion imaging and is a useful method for the diagnosis and follow-up of PE. (authors)

  12. Correlation of the perfusion scintigram with pulmonary functions in chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, Kou; Ashitaka, Tsuyoshi; Uchibori, Shigeyasu [Toho Univ., Tokyo (Japan). School of Medicine; Takano, Masaaki

    1992-11-01

    The authors carried out ventilation-perfusion scintigraphy and pulmonary function tests in 21 patients with chronic obstructive pulmonary disease. It was used [sup 99m]Tc-macroaggregate for perfusion scintigram and [sup 133]Xe gas for ventilation scintigram. It was added the radioactivities of rebreathing phase and made lung volume image using a computer. Regions of interest (ROIs) were derived from radioactivities in each image. ROIs on lung volume image included each whole lung and those on perfusion image included the areas which had relatively high radioactivity. The authors counted the area of ROIs on lung volume (L) and perfusion (P) images. Then it was used the ratio of perfusion to lung volume (P/L) as a parameter of pulmonary perfusion. P/L had the significant correlations with the vital capacity, the actual FFV[sub 1.0], arterial oxygen partial pressure, diffusing capacity, RV/TLC and peak flow rate. These results suggested that P/L was a useful parameter of pulmonary perfusion in chronic obstructive pulmonary disease. (author).

  13. MR-based assessment of pulmonary ventilation-perfusion in animal models

    International Nuclear Information System (INIS)

    Yang Jian; Wan Mingxi; Guo Youmin

    2003-01-01

    Objective: To show the feasibility and value in the diagnosis of airway obstruction and pulmonary embolism with MR oxygen-enhanced ventilation combined with pulmonary perfusion imaging. Methods: Eight canines were implemented for peripheral pulmonary embolism by intravenous injection of gelfoam granules at pulmonary segmental arterial level, and five of them were formed airway obstruction models by inserting self-made balloon catheter at second-bronchia. The oxygen-enhanced MR ventilation imaging was introduced by subtracting the images of pre- and post- inhaled pure oxygen. The MR pulmonary perfusion imaging was achieved by the first-pass contrast agent method. Moreover, the manifestation of MR ventilation and perfusion imaging was observed and contradistinguished with that of general pathologic anatomy, ventilation-perfusion scintigraphy, and pulmonary angiography. Results: The manifestations of airway obstruction regions in MR ventilation and perfusion imaging were matched, but those of pulmonary embolism regions were dismatched. The defect range of airway obstruction in MR ventilation image was smaller than that in ventilation scintigraphy. The abnormal perfusion regions of pulmonary embolism were divided into defect regions and reduce regions based on the time courses of signal intensity changes. The sensitivity and specificity of diagnosis on pulmonary embolism by MR ventilation combined with perfusion technique were 75.0% and 98.1%. The diagnostic results were in good coherence with ventilation-perfusion scintigraphy and pulmonary angiography (K=0.743, 0.899). Conclusion: The MR oxygen-enhanced ventilation combined with pulmonary perfusion imaging can be used to diagnose the airway and vascular abnormity in lung. This technique resembles the ventilation-perfusion scintigraphy. It can provide quantitative functional information and better spatial and temporal resolution, and possesses the value of clinical application

  14. The relationship between ventilatory lung motion and pulmonary perfusion shown by ventilatory lung motion imaging

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Nakatsuka, Tatsuya; Yoshimura, Kazuhiko; Hirose, Yoshiki; Hirayama, Jiro; Kobayashi, Toshio; Handa, Kenjiro

    1991-01-01

    Using ventilatory lung motion imaging, which was obtained from two perfusion lung scintigrams with 99m Tc-macroaggregated albumin taken in maximal inspiration and maximal expiration, the lung motion (E-I/I) of the each unilateral lung was studied in various cardiopulmonary diseases. The sum of (E-I)/I(+) of the unilateral lung was decreased in the diseased lung for localized pleuropulmonary diseases, including primary lung cancer and pleural thickening, and in both lungs for heart diseases, and diffuse pulmonary diseases including diffuse interstitial pneumonia and diffuse panbronchiolitis. The sum of (E-I)/I(+) of the both lungs, which correlated with vital capacity and PaO 2 , was decreased in diffuse interstitial pneumonia, pulmonary emphysema, diffuse panbronchiolitis, primary lung cancer, pleural diseases and so on. (E-I)/I(+), correlated with pulmonary perfusion (n=49, r=0.51, p 81m Kr or 133 Xe (n=49, r=0.61, p<0.001) than pulmonary perfusion. The ventilatory lung motion imaging, which demonstrates the motion of the intra-pulmonary areas and lung edges, appears useful for estimating pulmonary ventilation of the perfused area as well as pulmonary perfusion. (author)

  15. Pulmonary MR angiography and perfusion imaging—A review of methods and applications

    Energy Technology Data Exchange (ETDEWEB)

    Johns, Christopher S.; Swift, Andrew J.; Hughes, Paul J.C. [University of Sheffield (United Kingdom); Ohno, Yoshiharu [Division of Functional and Diagnostic Imaging Research, Department of Radiology, KobeUniversity Graduate School of Medicine, Kobe, Hyogo (Japan); Schiebler, Mark [UW-Madison School of Medicine and Public Health, Madison, WI (United States); Wild, Jim M., E-mail: j.m.wild@sheffield.ac.uk [University of Sheffield (United Kingdom)

    2017-01-15

    Highlights: • This article represents an overview of the methodology and clinical applications of pulmonary MRA and perfusion imaging. • Both contrast enhanced and non-contrast enhanced metholodology for MRA and perfusion are covered. • The current clinical uses and future directions of MRA and MR perfusion are discussed. - Abstract: The pulmonary vasculature and its role in perfusion and gas exchange is an important consideration in many conditions of the lung and heart. Currently the mainstay of imaging of the vasculature and perfusion of the lungs lies with CT and nuclear medicine perfusion scans, both of which require ionizing radiation exposure. Improvements in MRI techniques have increased the use of MRI in pulmonary vascular imaging. Here we review MRI methods for imaging the pulmonary vasculature and pulmonary perfusion, both using contrast enhanced and non-contrast enhanced methodology. In many centres pulmonary MR angiography and dynamic contrast enhanced perfusion MRI are now well established in the routine workflow of patients particularly with pulmonary hypertension and thromboembolic disease. However, these imaging modalities offer exciting new directions for future research and clinical use in other respiratory diseases where consideration of pulmonary perfusion and gas exchange can provide insight in to pathophysiology.

  16. Pulmonary MR angiography and perfusion imaging—A review of methods and applications

    International Nuclear Information System (INIS)

    Johns, Christopher S.; Swift, Andrew J.; Hughes, Paul J.C.; Ohno, Yoshiharu; Schiebler, Mark; Wild, Jim M.

    2017-01-01

    Highlights: • This article represents an overview of the methodology and clinical applications of pulmonary MRA and perfusion imaging. • Both contrast enhanced and non-contrast enhanced metholodology for MRA and perfusion are covered. • The current clinical uses and future directions of MRA and MR perfusion are discussed. - Abstract: The pulmonary vasculature and its role in perfusion and gas exchange is an important consideration in many conditions of the lung and heart. Currently the mainstay of imaging of the vasculature and perfusion of the lungs lies with CT and nuclear medicine perfusion scans, both of which require ionizing radiation exposure. Improvements in MRI techniques have increased the use of MRI in pulmonary vascular imaging. Here we review MRI methods for imaging the pulmonary vasculature and pulmonary perfusion, both using contrast enhanced and non-contrast enhanced methodology. In many centres pulmonary MR angiography and dynamic contrast enhanced perfusion MRI are now well established in the routine workflow of patients particularly with pulmonary hypertension and thromboembolic disease. However, these imaging modalities offer exciting new directions for future research and clinical use in other respiratory diseases where consideration of pulmonary perfusion and gas exchange can provide insight in to pathophysiology.

  17. Organ perfusion during voluntary pulmonary hyperinflation; a magnetic resonance imaging study

    DEFF Research Database (Denmark)

    Kristensen, Kasper Kyhl; Drvis, Ivan; Barak, Otto

    2016-01-01

    . Myocardial, pulmonary, skeletal muscle, kidney, and liver perfusion were evaluated by magnetic resonance imaging in 10 elite breath-hold divers at rest and during moderate GPI. Cardiac chamber volumes, stroke volume, and thus CO were determined from cardiac short-axis cine images. Organ volumes were assessed...

  18. Assessment of smoking-induced impairment of pulmonary perfusion using three-dimensional SPECT images

    Energy Technology Data Exchange (ETDEWEB)

    Miyasaka, Takashi [Toho Univ., Tokyo (Japan). School of Medicine

    1997-09-01

    The effects of smoking on ventilation-perfusion lung scintigrams were investigated. The subjects comprised 40 healthy males (28 smokers and 12 nonsmokers) without a history of cardiopulmonary disease and with normal chest radiographs. After acquisition of planar images of ventilation lung scintigrams with 370 MBq of {sup 133}Xe gas, planar images and SPECT images of pulmonary perfusion flow were obtained using 185 MBq of {sup 99m}Tc-MAA. Planar imaging showed perfusion defects in only 5 smokers. In contrast, 16 subjects were found to have perfusion defects on SPECT images (p<0.05), indicating the usefulness of SPECT images in detecting minor vascular damage of the lung. Although perfusion defects were common in the smokers (p<0.05), their relationship to the BRINKMAN index was uncertain. The perfusion defects found in the smokers were nonsegmental and commonly involved the right upper lobe. Ventilation scans revealed only delayed washout of {sup 133}Xe in 4 smokers, suggesting that smoking-induced abnormal perfusion on SPECT appears earlier than impaired ventilation on scintigrams. (author)

  19. Pulmonary ventilation and perfusion scintigraphy in patients with bronchial asthma

    International Nuclear Information System (INIS)

    Ono, Seiji; Hoshi, Hiroaki; Watanabe, Katsushi.

    1988-01-01

    Pulmonary ventilation and perfusion scan using Xe-133 gas and Tc-99m MAA were performed in 18 patients with bronchial asthma to evaluate the regional pulmonary function. The scintigraphic findings were compared with the results of the auscultation and the conventional pulmonary functioning examination (%FVC, %FEV 1.0 ). Ventilation image showed abnormality in 12 (70.6%) out of the asymptomatic 17 patients and perfusion image showed abnormality in 7 (41.2%) out of 17 patients. These 7 patients with abnormality on perfusion image all showed abnormality on ventilation image. The grade of abnormality in scintigraphic findings was compatible with the values of %FVC and %FEV 1.0 . In conclusion Xe-133 ventilation and Tc-99m MAA perfusion scan were useful procedures to estimate the pulmonary function of patients with bronchial asthma. (author)

  20. Idiopathic pulmonary fibrosis. A rare cause of scintigraphic ventilation-perfusion mismatch

    International Nuclear Information System (INIS)

    Pochis, W.T.; Krasnow, A.Z.; Collier, B.D.; Mewissen, M.W.; Almagro, U.A.; Hellman, R.S.; Isitman, A.T.

    1990-01-01

    A case of idiopathic pulmonary fibrosis with multiple areas of mismatch on ventilation-perfusion lung imaging in the absence of pulmonary embolism is presented. Idiopathic pulmonary fibrosis is one of the few nonembolic diseases producing a pulmonary ventilation-perfusion mismatch. In this condition, chest radiographs may not detect the full extent of disease, and xenon-133 ventilation imaging may be relatively insensitive to morbid changes in small airways. Thus, when examining patients with idiopathic pulmonary fibrosis, one should be aware that abnormal perfusion imaging patterns without matching ventilation abnormalities are not always due to embolism. In this setting, contrast pulmonary angiography is often needed for accurate differential diagnosis

  1. Idiopathic pulmonary fibrosis. A rare cause of scintigraphic ventilation-perfusion mismatch

    Energy Technology Data Exchange (ETDEWEB)

    Pochis, W.T.; Krasnow, A.Z.; Collier, B.D.; Mewissen, M.W.; Almagro, U.A.; Hellman, R.S.; Isitman, A.T. (Medical College of Wisconsin, Milwaukee (USA))

    1990-05-01

    A case of idiopathic pulmonary fibrosis with multiple areas of mismatch on ventilation-perfusion lung imaging in the absence of pulmonary embolism is presented. Idiopathic pulmonary fibrosis is one of the few nonembolic diseases producing a pulmonary ventilation-perfusion mismatch. In this condition, chest radiographs may not detect the full extent of disease, and xenon-133 ventilation imaging may be relatively insensitive to morbid changes in small airways. Thus, when examining patients with idiopathic pulmonary fibrosis, one should be aware that abnormal perfusion imaging patterns without matching ventilation abnormalities are not always due to embolism. In this setting, contrast pulmonary angiography is often needed for accurate differential diagnosis.

  2. Pulmonary artery perfusion versus no pulmonary perfusion during cardiopulmonary bypass in patients with COPD

    DEFF Research Database (Denmark)

    Buggeskov, Katrine B; Sundskard, Martin M; Jonassen, Thomas

    2016-01-01

    INTRODUCTION: Absence of pulmonary perfusion during cardiopulmonary bypass (CPB) may be associated with reduced postoperative oxygenation. Effects of active pulmonary artery perfusion were explored in patients with chronic obstructive pulmonary disease (COPD) undergoing cardiac surgery. METHODS: 90...... perfusion with normothermic oxygenated blood during cardiopulmonary bypass appears to improve postoperative oxygenation in patients with COPD undergoing cardiac surgery. Pulmonary artery perfusion with hypothermic HTK solution does not seem to improve postoperative oxygenation. TRIAL REGISTRATION NUMBER...

  3. Correlation of semiquantitative analysis of the distribution of pulmonary perfusion with pulmonary function in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Uchida, Kou; Nakayama, Hiroyuki; Yamagami, Ikue; Takahashi, Hideki; Takano, Masaaki.

    1997-01-01

    We carried out ventilation-perfusion scintigraphy and pulmonary function tests in 56 patients with chronic obstructive pulmonary disease (COPD) and 19 healthy volunteers. We used 99m Tc-macroaggregated albumin for the perfusion scintigraphy and 133 Xe gas for the ventilation scintigraphy. The lung volume image was created by computerized summation of the radioactivity in the rebreathing phase. Regions of interest (ROIs) were set automatically on lung volume image, which included each whole lung, and on perfusion image, including areas with relatively high radioactivity, with cut-off levels of 50%, 70%, and 90%. The number of pixels in each ROI was used as an index of lung volume (L) or perfusion (P). Perfusion per unit of lung volume (P/L) was also used as an index of perfusion. P70 and P70/L showed the better correlations than the other parameters, including significant correlations with vital capacity, FEV 1.0 , peak flow rate, RV/TLC, diffusing capacity and arterial oxygen partial pressure. The significant difference in P70 and P70/L between patients with hypoxemia and those without hypoxemia suggested that P70 and P70/L are useful indicators of the severity of COPD. We conclude that semiquantified values of pulmonary perfusion scintigraphy are significantly correlated with pulmonary function and the severity of COPD. (author)

  4. Relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism: assessment with breath-hold SPECT-CT pulmonary angiography fusion images.

    Science.gov (United States)

    Suga, Kazuyoshi; Yasuhiko, Kawakami; Iwanaga, Hideyuki; Tokuda, Osamu; Matsunaga, Naofumi

    2008-09-01

    The relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism (PTE) was comprehensively assessed on deep-inspiratory breath-hold (DIBrH) perfusion SPECT-computed tomographic pulmonary angiography (CTPA) fusion images. Subjects were 34 acute PTE patients, who had successfully performed DIBrH perfusion SPECT using a dual-headed SPECT and a respiratory tracking system. Automated DIBrH SPECT-CTPA fusion images were used to assess the relation between lung perfusion defects and intravascular clots detected by CTPA. DIBrH SPECT visualized 175 lobar/segmental or subsegmental defects in 34 patients, and CTPA visualized 61 intravascular clots at variable locations in 30 (88%) patients, but no clots in four (12%) patients. In 30 patients with clots, the fusion images confirmed that 69 (41%) perfusion defects (20 segmental, 45 subsegmental and 4 lobar defects) of total 166 defects were located in lung territories without clots, although the remaining 97 (58%) defects were located in lung territories with clots. Perfusion defect was absent in lung territories with clots (one lobar branch and three segmental branches) in four (12%) of these patients. In four patients without clots, nine perfusion defects including four segmental ones were present. Because of unexpected dissociation between intravascular clots and lung perfusion defects, the present fusion images will be a useful adjunct to CTPA in the diagnosis of acute PTE.

  5. sup(99m)Tc particle perfusion/sup(99m)Tc aerosol ventilation imaging using a subtraction technique in suspected pulmonary embolism

    International Nuclear Information System (INIS)

    Poeyhoenen, L.; Turjanmaa, V.; Virjo, A.

    1985-01-01

    It is generally acknowledged that ventilation-perfusion mismatch is diagnostic of pulmonary embolism. Lung ventilation imaging with radioactive gases is a good method for the detection of pulmonary embolism, but it is not in widespread use because of the limited availability of sup(81m)Kr gas and the poor physical properties of 133 Xe. Aerosols have been proposed, instead of gases for use in lung ventilation imaging. As perfusion and ventilation distributions may change very rapidly, the two imaging procedures should be done in rapid succession. The cheapest way to perform the combined perfusion-ventilation (Q/V) imaging is to use sup(99m)Tc-labelled macroaggregates and aerosols. In our method the perfusion imaging was done first, immediately followed by the ventilation imaging with sup(99m)Tc-labelled aerosols. A computer program was used to subtract the contribution of the perfusion from the combined Q/V image so that the pure ventilation image alone was obtained. The method was tested in 41 patients with suspected pulmonary embolism. (orig.)

  6. Single-energy computed tomography-based pulmonary perfusion imaging: Proof-of-principle in a canine model

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Tokihiro, E-mail: toyamamoto@ucdavis.edu [Department of Radiation Oncology, University of California Davis School of Medicine, Sacramento, California 95817 (United States); Kent, Michael S.; Wisner, Erik R. [Department of Surgical and Radiological Sciences, University of California Davis School of Veterinary Medicine, Davis, California 95616 (United States); Johnson, Lynelle R.; Stern, Joshua A. [Department of Medicine and Epidemiology, University of California Davis School of Veterinary Medicine, Davis, California 95616 (United States); Qi, Lihong [Department of Public Health Sciences, University of California Davis, Davis, California 95616 (United States); Fujita, Yukio [Department of Radiation Oncology, Tokai University, Isehara, Kanagawa 259-1193 (Japan); Boone, John M. [Department of Radiology, University of California Davis School of Medicine, Sacramento, California 95817 (United States)

    2016-07-15

    Purpose: Radiotherapy (RT) that selectively avoids irradiating highly functional lung regions may reduce pulmonary toxicity, which is substantial in lung cancer RT. Single-energy computed tomography (CT) pulmonary perfusion imaging has several advantages (e.g., higher resolution) over other modalities and has great potential for widespread clinical implementation, particularly in RT. The purpose of this study was to establish proof-of-principle for single-energy CT perfusion imaging. Methods: Single-energy CT perfusion imaging is based on the following: (1) acquisition of end-inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast agents, (2) deformable image registration (DIR) for spatial mapping of those two CT image data sets, and (3) subtraction of the precontrast image data set from the postcontrast image data set, yielding a map of regional Hounsfield unit (HU) enhancement, a surrogate for regional perfusion. In a protocol approved by the institutional animal care and use committee, the authors acquired CT scans in the prone position for a total of 14 anesthetized canines (seven canines with normal lungs and seven canines with diseased lungs). The elastix algorithm was used for DIR. The accuracy of DIR was evaluated based on the target registration error (TRE) of 50 anatomic pulmonary landmarks per subject for 10 randomly selected subjects as well as on singularities (i.e., regions where the displacement vector field is not bijective). Prior to perfusion computation, HUs of the precontrast end-inspiratory image were corrected for variation in the lung inflation level between the precontrast and postcontrast end-inspiratory CT scans, using a model built from two additional precontrast CT scans at end-expiration and midinspiration. The authors also assessed spatial heterogeneity and gravitationally directed gradients of regional perfusion for normal lung subjects and diseased lung subjects using a two-sample two-tailed t

  7. Single-energy computed tomography-based pulmonary perfusion imaging: Proof-of-principle in a canine model.

    Science.gov (United States)

    Yamamoto, Tokihiro; Kent, Michael S; Wisner, Erik R; Johnson, Lynelle R; Stern, Joshua A; Qi, Lihong; Fujita, Yukio; Boone, John M

    2016-07-01

    Radiotherapy (RT) that selectively avoids irradiating highly functional lung regions may reduce pulmonary toxicity, which is substantial in lung cancer RT. Single-energy computed tomography (CT) pulmonary perfusion imaging has several advantages (e.g., higher resolution) over other modalities and has great potential for widespread clinical implementation, particularly in RT. The purpose of this study was to establish proof-of-principle for single-energy CT perfusion imaging. Single-energy CT perfusion imaging is based on the following: (1) acquisition of end-inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast agents, (2) deformable image registration (DIR) for spatial mapping of those two CT image data sets, and (3) subtraction of the precontrast image data set from the postcontrast image data set, yielding a map of regional Hounsfield unit (HU) enhancement, a surrogate for regional perfusion. In a protocol approved by the institutional animal care and use committee, the authors acquired CT scans in the prone position for a total of 14 anesthetized canines (seven canines with normal lungs and seven canines with diseased lungs). The elastix algorithm was used for DIR. The accuracy of DIR was evaluated based on the target registration error (TRE) of 50 anatomic pulmonary landmarks per subject for 10 randomly selected subjects as well as on singularities (i.e., regions where the displacement vector field is not bijective). Prior to perfusion computation, HUs of the precontrast end-inspiratory image were corrected for variation in the lung inflation level between the precontrast and postcontrast end-inspiratory CT scans, using a model built from two additional precontrast CT scans at end-expiration and midinspiration. The authors also assessed spatial heterogeneity and gravitationally directed gradients of regional perfusion for normal lung subjects and diseased lung subjects using a two-sample two-tailed t-test. The mean TRE

  8. Single-energy computed tomography-based pulmonary perfusion imaging: Proof-of-principle in a canine model

    International Nuclear Information System (INIS)

    Yamamoto, Tokihiro; Kent, Michael S.; Wisner, Erik R.; Johnson, Lynelle R.; Stern, Joshua A.; Qi, Lihong; Fujita, Yukio; Boone, John M.

    2016-01-01

    Purpose: Radiotherapy (RT) that selectively avoids irradiating highly functional lung regions may reduce pulmonary toxicity, which is substantial in lung cancer RT. Single-energy computed tomography (CT) pulmonary perfusion imaging has several advantages (e.g., higher resolution) over other modalities and has great potential for widespread clinical implementation, particularly in RT. The purpose of this study was to establish proof-of-principle for single-energy CT perfusion imaging. Methods: Single-energy CT perfusion imaging is based on the following: (1) acquisition of end-inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast agents, (2) deformable image registration (DIR) for spatial mapping of those two CT image data sets, and (3) subtraction of the precontrast image data set from the postcontrast image data set, yielding a map of regional Hounsfield unit (HU) enhancement, a surrogate for regional perfusion. In a protocol approved by the institutional animal care and use committee, the authors acquired CT scans in the prone position for a total of 14 anesthetized canines (seven canines with normal lungs and seven canines with diseased lungs). The elastix algorithm was used for DIR. The accuracy of DIR was evaluated based on the target registration error (TRE) of 50 anatomic pulmonary landmarks per subject for 10 randomly selected subjects as well as on singularities (i.e., regions where the displacement vector field is not bijective). Prior to perfusion computation, HUs of the precontrast end-inspiratory image were corrected for variation in the lung inflation level between the precontrast and postcontrast end-inspiratory CT scans, using a model built from two additional precontrast CT scans at end-expiration and midinspiration. The authors also assessed spatial heterogeneity and gravitationally directed gradients of regional perfusion for normal lung subjects and diseased lung subjects using a two-sample two-tailed t

  9. Physiology for the pulmonary functional imager

    Energy Technology Data Exchange (ETDEWEB)

    Levin, David L., E-mail: levin.david@mayo.edu [Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN 55905 (United States); Schiebler, Mark L. [Department of Radiology, UW-Madison School of Medicine and Public Health, 600 Highland Avenue, Madison, WI 53792-3252 (United States); Hopkins, Susan R., E-mail: shopkins@ucsd.edu [Division of Physiology 0623A, University of California, San Diego, 9500 Gilman Dr., La Jolla, CA 92093 (United States)

    2017-01-15

    Highlights: • An understanding of the relevant pulmonary physiology is crucial to functional lung imaging. • Spatial resolution for pulmonary functional imaging can be substantially less than that used for anatomic/clinical imaging. • Regional deformation of the lung under the influence of gravity significantly affects the measurement of pulmonary perfusion. • Large vessels identified on perfusion imaging do not represent local blood flow. • Pulmonary diseases are typically characterized by a change in the matching of ventilation and perfusion. - Abstract: As pulmonary functional imaging moves beyond the realm of the radiologist and physicist, it is important that imagers have a common language and understanding of the relevant physiology of the lung. This review will focus on key physiological concepts and pitfalls relevant to functional lung imaging.

  10. Physiology for the pulmonary functional imager

    International Nuclear Information System (INIS)

    Levin, David L.; Schiebler, Mark L.; Hopkins, Susan R.

    2017-01-01

    Highlights: • An understanding of the relevant pulmonary physiology is crucial to functional lung imaging. • Spatial resolution for pulmonary functional imaging can be substantially less than that used for anatomic/clinical imaging. • Regional deformation of the lung under the influence of gravity significantly affects the measurement of pulmonary perfusion. • Large vessels identified on perfusion imaging do not represent local blood flow. • Pulmonary diseases are typically characterized by a change in the matching of ventilation and perfusion. - Abstract: As pulmonary functional imaging moves beyond the realm of the radiologist and physicist, it is important that imagers have a common language and understanding of the relevant physiology of the lung. This review will focus on key physiological concepts and pitfalls relevant to functional lung imaging.

  11. Ventilation-perfusion imaging and pulmonary angiography: changing pattern of use

    International Nuclear Information System (INIS)

    Teates, C.D.; Bezirdjian, D.R.; Bray, S.T.; Tegtmeyer, C.J.

    1981-01-01

    The hospital and departmental records of the University of Virginia Medical Center from 1976 to 1980 show an increasing frequency of ventilation studies relative to perfusion studies and a decrease in frequency of ventilation-perfusion diagnosis of pulmonary embolus. Pulmonary angiograms have increased from one per 68 nuclear studies to one per 14. A review of 70 patients with correlating angiography or autopsy shows that 89% of nuclear studies were accurate. We have revised our interpretation criteria and indications for pulmonary angiography

  12. Heterogeneity of pulmonary perfusion as a mechanistic image-based phenotype in emphysema susceptible smokers.

    Science.gov (United States)

    Alford, Sara K; van Beek, Edwin J R; McLennan, Geoffrey; Hoffman, Eric A

    2010-04-20

    Recent evidence suggests that endothelial dysfunction and pathology of pulmonary vascular responses may serve as a precursor to smoking-associated emphysema. Although it is known that emphysematous destruction leads to vasculature changes, less is known about early regional vascular dysfunction which may contribute to and precede emphysematous changes. We sought to test the hypothesis, via multidetector row CT (MDCT) perfusion imaging, that smokers showing early signs of emphysema susceptibility have a greater heterogeneity in regional perfusion parameters than emphysema-free smokers and persons who had never smoked (NS). Assuming that all smokers have a consistent inflammatory response, increased perfusion heterogeneity in emphysema-susceptible smokers would be consistent with the notion that these subjects may have the inability to block hypoxic vasoconstriction in patchy, small regions of inflammation. Dynamic ECG-gated MDCT perfusion scans with a central bolus injection of contrast were acquired in 17 NS, 12 smokers with normal CT imaging studies (SNI), and 12 smokers with subtle CT findings of centrilobular emphysema (SCE). All subjects had normal spirometry. Quantitative image analysis determined regional perfusion parameters, pulmonary blood flow (PBF), and mean transit time (MTT). Mean and coefficient of variation were calculated, and statistical differences were assessed with one-way ANOVA. MDCT-based MTT and PBF measurements demonstrate globally increased heterogeneity in SCE subjects compared with NS and SNI subjects but demonstrate similarity between NS and SNI subjects. These findings demonstrate a functional lung-imaging measure that provides a more mechanistically oriented phenotype that differentiates smokers with and without evidence of emphysema susceptibility.

  13. Unusual ventilation perfusion scintigram in a case of immunologic pulmonary edema clinically simulating pulmonary embolism

    International Nuclear Information System (INIS)

    Campeau, R.J.; Faust, J.M.; Ahmad, S.

    1987-01-01

    A case of immunologic pulmonary edema secondary to hydrochlorothiazide allergy developed in a 55-year-old woman that clinically simulated pulmonary embolism. The patient had abnormal washin images with normal washout images on an Xe-133 ventilation study. On the perfusion study, large bilateral central and posterior perfusion defects were present that showed an unusual mirror image pattern on the lateral and posterior oblique views. Resolution of radiographic and scintigraphic abnormalities occurred over a 3-day period in conjunction with corticosteroid therapy

  14. Assessment of pulmonary parenchyma perfusion with FAIR in comparison with DCE-MRI-Initial results

    Energy Technology Data Exchange (ETDEWEB)

    Fan Li [Department of Radiology, ChangZheng Hospital Affiliated to Second Military Medical University, No. 415 Fengyang Road, Shanghai 200003 (China)], E-mail: fanli0930@163.com; Liu Shiyuan [Department of Radiology, ChangZheng Hospital Affiliated to Second Military Medical University, No. 415 Fengyang Road, Shanghai 200003 (China); Sun Fei [GE Healthcare China (China)], E-mail: Fei.sun@med.ge.com; Xiao Xiangsheng [Department of Radiology, ChangZheng Hospital Affiliated to Second Military Medical University, No. 415 Fengyang Road, Shanghai 200003 (China)], E-mail: lizhaobin79@163.com

    2009-04-15

    Objective: The aim of this study was to assess pulmonary parenchyma perfusion with flow-sensitive alternating inversion recovery (FAIR) in comparison with 3D dynamic contrast-enhanced (DCE) imaging in healthy volunteers and in patients with pulmonary embolism or lung cancer. Materials and methods: Sixteen healthy volunteers and 16 patients with pulmonary embolism (5 cases) or lung cancer (11 cases) were included in this study. Firstly, the optimized inversion time of FAIR (TI) was determined in 12 healthy volunteers. Then, FAIR imaging with the optimized TI was performed followed by DCE-MRI on the other 4 healthy volunteers and 16 patients. Tagging efficiency of lung and SNR of perfusion images were calculated with different TI values. In the comparison of FAIR with DCE-MRI, the homogeneity of FAIR and DCE-MRI perfusion was assessed. In the cases of perfusion abnormality, the contrast between normal lung and perfusion defects was quantified by calculating a normalized signal intensity ratio. Results: One thousand milliseconds was the optimal TI, which generated the highest lung tagging efficiency and second highest PBF SNR. In the volunteers, the signal intensity of perfusion images acquired with both FAIR and DCE-MRI was homogeneous. Wedged-shaped or triangle perfusion defects were visualized in five pulmonary embolisms and three lung cancer cases. There was no significant statistical difference in signal intensity ratio between FAIR and DCE-MRI (P > 0.05). In the rest of eight lung cancers, all the lesions showed low perfusion against the higher perfused pulmonary parenchyma in both FAIR and DCE-MRI. Conclusion: Pulmonary parenchyma perfusion imaging with FAIR was feasible, consistent and could obtain similar functional information to that from DCE-MRI.

  15. Assessment of pulmonary parenchyma perfusion with FAIR in comparison with DCE-MRI-Initial results

    International Nuclear Information System (INIS)

    Fan Li; Liu Shiyuan; Sun Fei; Xiao Xiangsheng

    2009-01-01

    Objective: The aim of this study was to assess pulmonary parenchyma perfusion with flow-sensitive alternating inversion recovery (FAIR) in comparison with 3D dynamic contrast-enhanced (DCE) imaging in healthy volunteers and in patients with pulmonary embolism or lung cancer. Materials and methods: Sixteen healthy volunteers and 16 patients with pulmonary embolism (5 cases) or lung cancer (11 cases) were included in this study. Firstly, the optimized inversion time of FAIR (TI) was determined in 12 healthy volunteers. Then, FAIR imaging with the optimized TI was performed followed by DCE-MRI on the other 4 healthy volunteers and 16 patients. Tagging efficiency of lung and SNR of perfusion images were calculated with different TI values. In the comparison of FAIR with DCE-MRI, the homogeneity of FAIR and DCE-MRI perfusion was assessed. In the cases of perfusion abnormality, the contrast between normal lung and perfusion defects was quantified by calculating a normalized signal intensity ratio. Results: One thousand milliseconds was the optimal TI, which generated the highest lung tagging efficiency and second highest PBF SNR. In the volunteers, the signal intensity of perfusion images acquired with both FAIR and DCE-MRI was homogeneous. Wedged-shaped or triangle perfusion defects were visualized in five pulmonary embolisms and three lung cancer cases. There was no significant statistical difference in signal intensity ratio between FAIR and DCE-MRI (P > 0.05). In the rest of eight lung cancers, all the lesions showed low perfusion against the higher perfused pulmonary parenchyma in both FAIR and DCE-MRI. Conclusion: Pulmonary parenchyma perfusion imaging with FAIR was feasible, consistent and could obtain similar functional information to that from DCE-MRI.

  16. Comparative analysis of radionuclide inhalation and perfusion lung imaging with X ray pulmonary angiography for the diagnosis of pulmonary embolism

    International Nuclear Information System (INIS)

    Zhang Yanyan; Chen Man; Shao Maogang; Zhang Songlin; Mao Jieming; Guo Jingxuan

    1993-01-01

    The result of radionuclide lung imaging was compared in 18 patients of pulmonary embolism (PE) and 2 normal persons. The discovered perfusion defects correlated well with the location of angiographic obstruction. The positive angiographic and radionuclide finding was in 141 and 104 emboli arteries respectively. The sensitivity of total emboli pulmonary segments of lung imaging was 73.8%, the specificity was 82.7 and the accuracy was 79%. The techniques correlated quite well (r = 0.83, P<0.001)

  17. TU-CD-BRA-08: Single-Energy Computed Tomography-Based Pulmonary Perfusion Imaging: Proof-Of-Principle in a Canine Model

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, T; Boone, J [University of California Davis School of Medicine, Sacramento, CA (United States); Kent, M; Wisner, E [University of California Davis School of Veterinary Medicine, Davis, CA (United States); Fujita, Y [Tokai University, Isehara (Japan)

    2015-06-15

    Purpose: Pulmonary perfusion imaging has provided significant insights into pulmonary diseases, and can be useful in radiotherapy. The purpose of this study was to prospectively establish proof-of-principle in a canine model for single-energy CT-based perfusion imaging, which has the potential for widespread clinical implementation. Methods: Single-energy CT perfusion imaging is based on: (1) acquisition of inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast medium, (2) deformable image registration (DIR) of the two CT image data sets, and (3) subtraction of the pre-contrast image from post-contrast image, yielding a map of Hounsfield unit (HU) enhancement. These subtraction image data sets hypothetically represent perfused blood volume, a surrogate for perfusion. In an IACUC-approved clinical trial, we acquired pre- and post-contrast CT scans in the prone posture for six anesthetized, mechanically-ventilated dogs. The elastix algorithm was used for DIR. The registration accuracy was quantified using the target registration errors (TREs) for 50 pulmonary landmarks in each dog. The gradient of HU enhancement between gravity-dependent (ventral) and non-dependent (dorsal) regions was evaluated to quantify the known effect of gravity, i.e., greater perfusion in ventral regions. Results: The lung volume difference between the two scans was 4.3±3.5% on average (range 0.3%–10.1%). DIR demonstrated an average TRE of 0.7±1.0 mm. HU enhancement in lung parenchyma was 34±10 HU on average and varied considerably between individual dogs, indicating the need for improvement of the contrast injection protocol. HU enhancement in ventral (gravity-dependent) regions was found to be greater than in dorsal regions. A population average ventral-to-dorsal gradient of HU enhancement was strong (R{sup 2}=0.94) and statistically significant (p<0.01). Conclusion: This canine study demonstrated relatively accurate DIR and a strong ventral

  18. TU-CD-BRA-08: Single-Energy Computed Tomography-Based Pulmonary Perfusion Imaging: Proof-Of-Principle in a Canine Model

    International Nuclear Information System (INIS)

    Yamamoto, T; Boone, J; Kent, M; Wisner, E; Fujita, Y

    2015-01-01

    Purpose: Pulmonary perfusion imaging has provided significant insights into pulmonary diseases, and can be useful in radiotherapy. The purpose of this study was to prospectively establish proof-of-principle in a canine model for single-energy CT-based perfusion imaging, which has the potential for widespread clinical implementation. Methods: Single-energy CT perfusion imaging is based on: (1) acquisition of inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast medium, (2) deformable image registration (DIR) of the two CT image data sets, and (3) subtraction of the pre-contrast image from post-contrast image, yielding a map of Hounsfield unit (HU) enhancement. These subtraction image data sets hypothetically represent perfused blood volume, a surrogate for perfusion. In an IACUC-approved clinical trial, we acquired pre- and post-contrast CT scans in the prone posture for six anesthetized, mechanically-ventilated dogs. The elastix algorithm was used for DIR. The registration accuracy was quantified using the target registration errors (TREs) for 50 pulmonary landmarks in each dog. The gradient of HU enhancement between gravity-dependent (ventral) and non-dependent (dorsal) regions was evaluated to quantify the known effect of gravity, i.e., greater perfusion in ventral regions. Results: The lung volume difference between the two scans was 4.3±3.5% on average (range 0.3%–10.1%). DIR demonstrated an average TRE of 0.7±1.0 mm. HU enhancement in lung parenchyma was 34±10 HU on average and varied considerably between individual dogs, indicating the need for improvement of the contrast injection protocol. HU enhancement in ventral (gravity-dependent) regions was found to be greater than in dorsal regions. A population average ventral-to-dorsal gradient of HU enhancement was strong (R"2=0.94) and statistically significant (p<0.01). Conclusion: This canine study demonstrated relatively accurate DIR and a strong ventral

  19. Risk stratification of patients with combined acute pulmonary embolism and pulmonary hypertension using dynamic and regular pulmonary perfusion imaging

    International Nuclear Information System (INIS)

    Wang Xuemei; Wang Jing; Li Guohua; Wang Xiangcheng; Zhang Kaixiu; Liu Caiping

    2010-01-01

    Objective: To stratify the risks of patients with acute pulmonary embolism (APE) and pulmonary hypertension (PH) by dynamic pulmonary perfusion imaging (DPPI) and pulmonary perfusion imaging (PPI). Methods: From October 2007 to February 2009, 20 healthy volunteers (12 males, 8 females; mean age =48.47±13.47 years) and 31 APE patients (21 males, 10 females; mean age =47.68±18.06 years; from October 2007 to July 2009) were included in the study. DPPI and PPI were performed in all subjects. Percentage of perfusion defect scores (PPDs%) were calculated by semi-quantitative analysis of PPI. Risk levels were defined according to PPDs% calculated from PPI: normal (PPDs% =0); very low risk (0 60%). Lung equilibrium time (LET) was calculated on region of interest (ROI) drawn over DPPI. Clinical risk was scored by Aujesky method.The t-test, ANOVA and correlation analysis were used with SPSS 13.0 software. Results: (1) LET in healthy volunteers and APE patients was (12.18±3.28) and (32.90±14.29) s respectively (t = 6.81, P<0.01). (2) The correlation coefficient, coefficient of determination between LET and PPDs% in APE patients were 0.93 and 0.87, respectively. The correlation coefficient between LET and clinical risk score was 0.86. (3) The mean LET of APE patients in very low risk (n =5), low risk (n = 12), moderate risk (n=9), high risk (n=4) and very high risk groups (n=1) were (19.59 ±0.04), (25.03±0.08), (36.07±0.10), (57.15±0.06) and (70±0.00) s, respectively. There was significant difference among APE patients with different risk levels (F =16.78, P<0.01). Conclusions: (1) DPPI was a reliable, convenient and non-invasive method for the evaluation of PH in APE. (2) Combined LET of DPPI and PPDs% of PPI was valuable for risk stratification and prognosis estimation in APE patients. (authors)

  20. Clinical evaluation of pulmonary perfusion MRI using FAIR (flow-sensitive alternating inversion recovery)-HASTE (Half-Fourier Single-Shot TurboSE) method

    International Nuclear Information System (INIS)

    Togami, Izumi; Sasai, Nobuya; Tsunoda, Masatoshi; Sei, Tetsurou; Sato, Shuhei; Yabuki, Takayuki; Hiraki, Yoshio

    2002-01-01

    The FAIR-HASTE method is a kind of noninvasive perfusion MR imaging obtained without the use of contrast media. By subtracting a flow-insensitive image from a flow-sensitive image, contrast enhancement of inflowing blood achieved. In the present study, we applied pulmonary perfusion FAIR-HASTE sequence for 23 patients with various pulmonary diseases, and compared the findings with those by pulmonary perfusion scintigraphy and Gadolinium perfusion MRI. Pulmonary perfusion imaging with the FAIR-HASTE method was possible in all clinical cases, and the findings corresponded well to those obtained by perfusion MRI using contrast media or pulmonary scintigraphy. The FAIR-HASTE method is a promising method for the evaluation of pulmonary perfusion. (author)

  1. Magnetic resonance imaging of pulmonary perfusion. Technical requirements and diagnostic impact; MRT der Lungenperfusion. Technische Voraussetzungen und diagnostischer Stellenwert

    Energy Technology Data Exchange (ETDEWEB)

    Attenberger, U.I.; Buesing, K.; Schoenberg, S.O.; Fink, C. [Klinikum Mannheim der Universitaet Heidelberg, Institut fuer Klinische Radiologie und Nuklearmedizin, Universitaetsmedizin Mannheim, Mannheim (Germany); Ingrisch, M.; Reiser, M. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Campus Grosshadern, Muenchen (Germany)

    2009-08-15

    With technical improvements in gradient hardware and the implementation of innovative k-space sampling techniques, such as parallel imaging, the feasibility of pulmonary perfusion MRI could be demonstrated in several studies. Dynamic contrast-enhanced 3D gradient echo sequences as used for time-resolved MR angiography have been established as the preferred pulse sequences for lung perfusion MRI. With these techniques perfusion of the entire lung can be visualized with a sufficiently high temporal and spatial resolution. In several trials in patients with acute pulmonary embolism, pulmonary hypertension and airway diseases, the clinical benefit and good correlation with perfusion scintigraphy have been demonstrated. The following review article describes the technical prerequisites, current post-processing techniques and the clinical indications for MR pulmonary perfusion imaging using MRI. (orig.) [German] Mit der Verfuegbarkeit leistungsfaehiger Gradientensysteme und schneller k-Raum-Akquisitionstechniken wie der parallelen Bildgebung konnten verschiedene Studien die Machbarkeit der Lungenperfusionsbildgebung in der MRT zeigen. In der Praxis haben sich dynamische kontrastverstaerkte 3D-Gradientenechosequenzen, wie sie fuer zeitaufgeloeste MR-Angiographien verwendet werden, fuer die Bildgebung der Lungenperfusion etabliert. Hiermit ist es moeglich, die Perfusion der gesamten Lunge mit ausreichend hoher zeitlicher und raeumlicher Aufloesung zu visualisieren. In mehren klinischen Studien konnte bei Patienten mit Lungenembolie, pulmonaler Hypertonie sowie Erkrankungen der Atemwege und des Lungenparenchyms der klinische Nutzen der Lungenperfusions-MRT und die gute Uebereinstimmung mit der Lungenperfusionsszintigraphie nachgewiesen werden. Der folgende Uebersichtsartikel beschreibt die technische Durchfuehrung, Bildnachverarbeitung und die klinischen Anwendungsgebiete der MRT zur Untersuchung der Lungenperfusion. (orig.)

  2. Pulmonary ventilation and perfusion abnormalities and ventilation perfusion imbalance in children with pulmonary atresia or extreme tetralogy of Fallot

    Energy Technology Data Exchange (ETDEWEB)

    Dowdle, S.C.; Human, D.G.; Mann, M.D. (Univ. of Cape Town (South Africa))

    1990-08-01

    Xenon-133 lung ventilation and perfusion scans were done preoperatively after cardiac catheterization and cineangiocardiography in 19 children; 6 had pulmonary atresia with an intact ventricular septum and hypoplastic right ventricle, 4 pulmonary atresia with associated complex univentricular heart, and 9 extreme Tetralogy of Fallot. The four patients with discrepancies in the sizes of the left and right pulmonary arteries on angiography had marked asymmetry of pulmonary perfusion and ventilation-perfusion imbalance on scintigraphy. Similar degrees of asymmetry and imbalance were present in 6 of the 15 children with equal-size pulmonary vessels. Asymmetry of pulmonary perfusion and ventilation-perfusion imbalance were associated with a poor prognosis.

  3. Pulmonary ventilation and perfusion abnormalities and ventilation perfusion imbalance in children with pulmonary atresia or extreme tetralogy of Fallot

    International Nuclear Information System (INIS)

    Dowdle, S.C.; Human, D.G.; Mann, M.D.

    1990-01-01

    Xenon-133 lung ventilation and perfusion scans were done preoperatively after cardiac catheterization and cineangiocardiography in 19 children; 6 had pulmonary atresia with an intact ventricular septum and hypoplastic right ventricle, 4 pulmonary atresia with associated complex univentricular heart, and 9 extreme Tetralogy of Fallot. The four patients with discrepancies in the sizes of the left and right pulmonary arteries on angiography had marked asymmetry of pulmonary perfusion and ventilation-perfusion imbalance on scintigraphy. Similar degrees of asymmetry and imbalance were present in 6 of the 15 children with equal-size pulmonary vessels. Asymmetry of pulmonary perfusion and ventilation-perfusion imbalance were associated with a poor prognosis

  4. Right ventricle performances with echocardiography and 99mTc myocardial perfusion imaging in pulmonary arterial hypertension patients.

    Science.gov (United States)

    Liu, Jie; Fei, Lei; Huang, Guang-Qing; Shang, Xiao-Ke; Liu, Mei; Pei, Zhi-Jun; Zhang, Yong-Xue

    2018-05-01

    Right heart catheterization is commonly used to measure right ventricle hemodynamic parameters and is the gold standard for pulmonary arterial hypertension diagnosis; however, it is not suitable for patients' long-term follow-up. Non-invasive echocardiography and nuclear medicine have been applied to measure right ventricle anatomy and function, but the guidelines for the usefulness of clinical parameters remain to be established. The goal of this study is to identify reliable clinical parameters of right ventricle function in pulmonary arterial hypertension patients and analyze the relationship of these clinical parameters with the disease severity of pulmonary arterial hypertension. In this study, 23 normal subjects and 23 pulmonary arterial hypertension patients were recruited from January 2015 to March 2016. Pulmonary arterial hypertension patients were classified into moderate and severe pulmonary arterial hypertension groups according to their mean pulmonary arterial pressure levels. All the subjects were subjected to physical examination, chest X-ray, 12-lead electrocardiogram, right heart catheterization, two-dimensional echocardiography, and technetium 99m ( 99m Tc) myocardial perfusion imaging. Compared to normal subjects, the right heart catheterization indexes including right ventricle systolic pressure, right ventricle end diastolic pressure, pulmonary artery systolic pressure, pulmonary artery diastolic pressure, pulmonary vascular resistance, and right ventricle end systolic pressure increased in pulmonary arterial hypertension patients and were correlated with mean pulmonary arterial pressure levels. Echocardiography parameters, including tricuspid regurgitation peak velocity, tricuspid regurgitation pressure gradient, tricuspid annular plane systolic excursion and fractional area, right ventricle-myocardial performance index, were significantly associated with the mean pulmonary arterial pressure levels in pulmonary arterial hypertension patients

  5. Impact of CT perfusion imaging on the assessment of peripheral chronic pulmonary thromboembolism: clinical experience in 62 patients

    Energy Technology Data Exchange (ETDEWEB)

    Le Faivre, Julien; Khung, Suonita; Faivre, Jean-Baptiste; Remy, Jacques; Remy-Jardin, Martine [University of Lille, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Duhamel, Alain [University of Lille, Department of Biostatistics, Lille (France); Lamblin, Nicolas [University of Lille, Department of Cardiology, Cardiology Hospital, Lille (France)

    2016-11-15

    To evaluate the impact of CT perfusion imaging on the detection of peripheral chronic pulmonary embolisms (CPE). 62 patients underwent a dual-energy chest CT angiographic examination with (a) reconstruction of diagnostic and perfusion images; (b) enabling depiction of vascular features of peripheral CPE on diagnostic images and perfusion defects (20 segments/patient; total: 1240 segments examined). The interpretation of diagnostic images was of two types: (a) standard (i.e., based on cross-sectional images alone) or (b) detailed (i.e., based on cross-sectional images and MIPs). The segment-based analysis showed (a) 1179 segments analyzable on both imaging modalities and 61 segments rated as nonanalyzable on perfusion images; (b) the percentage of diseased segments was increased by 7.2 % when perfusion imaging was compared to the detailed reading of diagnostic images, and by 26.6 % when compared to the standard reading of images. At a patient level, the extent of peripheral CPE was higher on perfusion imaging, with a greater impact when compared to the standard reading of diagnostic images (number of patients with a greater number of diseased segments: n = 45; 72.6 % of the study population). Perfusion imaging allows recognition of a greater extent of peripheral CPE compared to diagnostic imaging. (orig.)

  6. Capability of differentiating smokers with normal pulmonary function from COPD patients: a comparison of CT pulmonary volume analysis and MR perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Li; Xia, Yi; Guan, Yu; Yu, Hong; Liu, Shi-yuan [Changzheng Hospital of the Second Military Medical University, Department of Radiology, Shanghai (China); Zhang, Tie-feng; Li, Bing [Changzheng Hospital of the Second Military Medical University, Department of Respiration Medicine, Shanghai (China)

    2013-05-15

    To compare CT volume analysis with MR perfusion imaging in differentiating smokers with normal pulmonary function (controls) from COPD patients. Sixty-two COPD patients and 17 controls were included. The total lung volume (TLV), total emphysema volume (TEV) and emphysema index (EI) were quantified by CT. MR perfusion evaluated positive enhancement integral (PEI), maximum slope of increase (MSI), maximum slope of decrease (MSD), signal enhancement ratio (SER) and signal intensity ratio (R{sub SI}) of perfusion defects to normal lung. There were 19 class I, 17 class II, 14 class III and 12 class IV COPD patients. No differences were observed in TLV, TEV and EI between control and class I COPD. The control was different from class II, III and IV COPD in TEV and EI. The control was different from each class of COPD in R{sub SI,} MSI, PEI and MSD. Differences were found in R{sub SI} between class I and III, I and IV, and II and IV COPD. Amongst controls, MR detected perfusion defects more frequently than CT detected emphysema. Compared with CT, MR perfusion imaging shows higher potential to distinguish controls from mild COPD and appears more sensitive in identifying abnormalities amongst smokers with normal pulmonary function (controls). (orig.)

  7. Capability of differentiating smokers with normal pulmonary function from COPD patients: a comparison of CT pulmonary volume analysis and MR perfusion imaging

    International Nuclear Information System (INIS)

    Fan, Li; Xia, Yi; Guan, Yu; Yu, Hong; Liu, Shi-yuan; Zhang, Tie-feng; Li, Bing

    2013-01-01

    To compare CT volume analysis with MR perfusion imaging in differentiating smokers with normal pulmonary function (controls) from COPD patients. Sixty-two COPD patients and 17 controls were included. The total lung volume (TLV), total emphysema volume (TEV) and emphysema index (EI) were quantified by CT. MR perfusion evaluated positive enhancement integral (PEI), maximum slope of increase (MSI), maximum slope of decrease (MSD), signal enhancement ratio (SER) and signal intensity ratio (R SI ) of perfusion defects to normal lung. There were 19 class I, 17 class II, 14 class III and 12 class IV COPD patients. No differences were observed in TLV, TEV and EI between control and class I COPD. The control was different from class II, III and IV COPD in TEV and EI. The control was different from each class of COPD in R SI, MSI, PEI and MSD. Differences were found in R SI between class I and III, I and IV, and II and IV COPD. Amongst controls, MR detected perfusion defects more frequently than CT detected emphysema. Compared with CT, MR perfusion imaging shows higher potential to distinguish controls from mild COPD and appears more sensitive in identifying abnormalities amongst smokers with normal pulmonary function (controls). (orig.)

  8. Impact of CT perfusion imaging on the assessment of peripheral chronic pulmonary thromboembolism: clinical experience in 62 patients.

    Science.gov (United States)

    Le Faivre, Julien; Duhamel, Alain; Khung, Suonita; Faivre, Jean-Baptiste; Lamblin, Nicolas; Remy, Jacques; Remy-Jardin, Martine

    2016-11-01

    To evaluate the impact of CT perfusion imaging on the detection of peripheral chronic pulmonary embolisms (CPE). 62 patients underwent a dual-energy chest CT angiographic examination with (a) reconstruction of diagnostic and perfusion images; (b) enabling depiction of vascular features of peripheral CPE on diagnostic images and perfusion defects (20 segments/patient; total: 1240 segments examined). The interpretation of diagnostic images was of two types: (a) standard (i.e., based on cross-sectional images alone) or (b) detailed (i.e., based on cross-sectional images and MIPs). The segment-based analysis showed (a) 1179 segments analyzable on both imaging modalities and 61 segments rated as nonanalyzable on perfusion images; (b) the percentage of diseased segments was increased by 7.2 % when perfusion imaging was compared to the detailed reading of diagnostic images, and by 26.6 % when compared to the standard reading of images. At a patient level, the extent of peripheral CPE was higher on perfusion imaging, with a greater impact when compared to the standard reading of diagnostic images (number of patients with a greater number of diseased segments: n = 45; 72.6 % of the study population). Perfusion imaging allows recognition of a greater extent of peripheral CPE compared to diagnostic imaging. • Dual-energy computed tomography generates standard diagnostic imaging and lung perfusion analysis. • Depiction of CPE on central arteries relies on standard diagnostic imaging. • Detection of peripheral CPE is improved by perfusion imaging.

  9. Scintigraphic and MR perfusion imaging in preoperative evaluation for lung volume reduction surgery. Pilot study results

    International Nuclear Information System (INIS)

    Johkoh, Takeshi; Mueller, N.L.; Kavanagh, P.V

    2000-01-01

    To compare MR perfusion imaging with perfusion scintigraphy in the evaluation of patients with pulmonary emphysema being considered for lung volume reduction surgery. Six patients with pulmonary emphysema and two normal individuals were evaluated by MR perfusion imaging, perfusion scintigraphy, and selective bilateral pulmonary angiography. MR images were obtained with an enhanced fast gradient recalled echo with three-dimensional Fourier transformation technique (efgre 3D) (6.3/1.3; flip angle, 30 deg C; field of view, 45-48 cm; matrix, 256 x 160). The presence or absence of perfusion defects in each segment was evaluated by two independent observers. Using angiography as the gold standard, the sensitivity, specificity, and accuracy of MR perfusion imaging in detecting focal perfusion abnormalities were 90%, 87%, and 89%, respectively, while those of perfusion scintigraphy were 71%, 76%, and 71%, respectively. The diagnostic accuracy of MR perfusion imaging was significantly higher than that of scintigraphy (p<0.001, McNemar test). There was good agreement between two observers for MR perfusion imaging (kappa statistic, 0.66) and only moderate agreement for perfusion scintigraphy (kappa statistic, 0.51). MR perfusion imaging is superior to perfusion scintigraphy in the evaluation of pulmonary parenchymal perfusion in patients with pulmonary emphysema. (author)

  10. Multi-slice spiral CT perfusion imaging of chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Shao Yanhui; Qian Nong; Xue Yuejun; Dao Yinhong

    2008-01-01

    Objective: To evaluate the diagnostic value of multi-slice spiral CT (MSCT) perfusion imaging in chronic obstructive pulmonary disease (COPD). Methods: Twenty COPD patients and 20 volunteers underwent 8-row detector spiral CT (MSCT) perfusion imaging using cine scan mode with 5 mm slice thickness, 0.5 s rotation time and a total scan time of 45 s with 5 s intervals. 60 ml contrast agent (300 nag I/ml) were administered at a rate of 4 ml/s from the forearm superficial vein. The imaging data were transferred to a workstation. A time-density curve and pseudo-color map were generated automatically with GE CT perfusion 3 software, the blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface (PS) were measured. Results: Time-density curve was flatter and the peak of the curve was obviously lower in COPD patients than the volunteers. The BF, BV, PS in COPD patients was (24.77±11.49) ml·min -1 ·100 g -1 , (2.48±1.02) ml/100 g and (2.75±1.13) ml· min -1 ·100 g -1 respectively. In volunteers was (290.14±107.59) ml·min -1 ·100 g -1 , (16.51 ± 5.98) ml/100 g, (8.80±3.03) ml·min -1 ·100 g -1 respectively. The MTT in COPD patients and volunteers was (10.58±4.85) s and (4.50±1.71)s respectively. The BF, BV and PS in COPD patients was lower than the volunteers, the MTY was higher (P<0.01). Conclusion: MSCT perfusion imaging is helpful for the diagnosis of COPD. (authors)

  11. In-effort perfusion pulmonary tomo-scintigraphies for pre-surgery evaluation of severe emphysema

    International Nuclear Information System (INIS)

    Poiseau, E.; Roue, C.; Bonnin, F.; Stievenart, J.L.; Fournier, M.; Bok, B.

    1997-01-01

    The pulmonary reduction surgery improves the in-effort tolerance of certain severe emphysema, possibly by the compression of zones of adjacent healthy pulmonary parenchyma. Six patients afflicted with severe emphysema (5 M and 1 F, 20 to 63 years old) benefited at each 3 days by an at-rest and in-effort perfusion pulmonary tomo-scintigraphy (PPTS), after a trial interval of 6 minutes. After injection IV of 6 mCi of MAA- 99m Tc, in sitting position, 120 projection images were acquired with a single-head camera on a 128 x 128 matrix, with a high resolution collimator. After reconstruction with a Metz filter, without corrections of attenuations, the coronal and cross sections were recorded on films in a standard procedure. These were visually interpreted by two independent senior physicians. The procedure has been tolerated by all the patients. Differences of pulmonary perfusion occurred at rest in comparison with the in-effort condition in 4 patients. In all the cases concerned were the zones of pulmonary parenchyma appearing as strongly injured in tomodensitometry. The in-effort pulmonary perfusion improves in 3 patients and impairs in one patient. The role of bubble and implied pulmonary diseases in the deterioration of pulmonary function, respectively, is difficult to estimate. The improvement of in-effort pulmonary perfusion could suggest the persistence of functional pulmonary tissue. On the other side, its deterioration could express the compressive character of bubbles and thus could be an indicator of severity. The observation during this pilot study of the differences between at-rest and in-effort pulmonary perfusion urges utilisation of a tool of analysis of image superposition (PPTS and scans) to study in a group of patients the correlations between the perfusion variations and the post-surgery development, in order to know better the pathophysiology of diseases and select better the patients

  12. Measurement of pulmonary vascular resistance of Fontan candidates with pulmonary arterial distortion by means of pulmonary perfusion imaging

    International Nuclear Information System (INIS)

    Park, In-Sam; Mizukami, Ayumi; Tomimatsu, Hirofumi; Kondou, Chisato; Nakanishi, Toshio; Nakazawa, Makoto; Momma, Kazuo

    1998-01-01

    We measured the distribution of blood flow to the right (R) and left lung (L) by means of pulmonary perfusion imaging and calculated pulmonary vascular resistance (Rp) in 13 patients, whose right and left pulmonary artery pressures were different by 2 to 9 mmHg due to pulmonary arterial distortion (5 interruption, 8 stenosis). The right lung/left lung blood flow ratio was determined and from the ratio and the total pulmonary blood flow, which was determined using the Fick's principle, the absolute values of right and left pulmonary blood flow were calculated. Using the right and left pulmonary blood flow and the right and left pulmonary arterial pressures, right and left pulmonary vascular resistance were calculated, separately. Vascular resistance of the whole lung (Rp) was then calculated using the following equation. 1/(Rp of total lung)=1/(Rp of right lung)+1/(Rp of left lung). Rp calculated from this equation was 1.8+/-0.8 U·m 2 and all values were less than 3 U·m 2 (range 0.3-2.8). Rp estimated from the conventional method using the total pulmonary blood flow and pulmonary arterial pressures, without using the right/left blood flow ratio, ranging from 0.4 to 3.8 U·m 2 and 5 of 13 patients showed Rp>3 U·m 2 . All patients underwent Fontan operation successfully. These data indicated that this method is useful to estimate Rp and to determine the indication of Fontan operation in patients with pulmonary arterial distortions. (author)

  13. MRI of pulmonary perfusion; MRT der Lungenperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Fink, C. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen (Germany). Institut fuer Klinische Radiologie; Deutsches Krebsforschungszentrum (DKFZ), Abteilung Radiologie, Heidelberg (Germany); Risse, F.; Semmler, W. [Deutsches Krebsforschungszentrum (DKFZ), Abteilung Medizinische Physik in der Radiologie, Heidelberg (Germany); Schoenberg, S.O.; Reiser, M.F. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen (Germany). Institut fuer Klinische Radiologie; Kauczor, H.-U. [Deutsches Krebsforschungszentrum (DKFZ), Abteilung Radiologie, Heidelberg (Germany)

    2006-04-15

    Lung perfusion is a crucial prerequisite for effective gas exchange. Quantification of pulmonary perfusion is important for diagnostic considerations and treatment planning in various diseases of the lungs. Besides disorders of pulmonary vessels such as acute pulmonary embolism and pulmonary hypertension, these also include diseases of the respiratory tract and lung tissue as well as pulmonary tumors. This contribution presents the possibilities and technical requirements of MRI for diagnostic work-up of pulmonary perfusion. (orig.) [German] Die Perfusion der Lunge ist eine entscheidende Voraussetzung fuer einen effektiven Gasaustausch. Die Bestimmung der Lungenperfusion ist bei verschiedenen Erkrankungen der Lunge fuer Diagnostik und Therapieplanung bedeutsam. Hierzu zaehlen neben Erkrankungen der Lungengefaesse wie akute Lungenembolie und pulmonale Hypertension ebenso Erkrankungen der Atemwege, des Lungengeruests und Lungentumoren. In diesem Beitrag werden die Moeglichkeiten und technischen Voraussetzungen der MRT zur Diagnostik der Lungenperfusion dargestellt. (orig.)

  14. Pulmonary function-morphologic relationships assessed by SPECT-CT fusion images

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi

    2012-01-01

    Pulmonary single photon emission computed tomography-computed tomography (SPECT-CT) fusion images provide objective and comprehensive assessment of pulmonary function and morphology relationships at cross-sectional lungs. This article reviewed the noteworthy findings of lung pathophysiology in wide-spectral lung disorders, which have been revealed on SPECT-CT fusion images in 8 years of experience. The fusion images confirmed the fundamental pathophysiologic appearance of lung low CT attenuation caused by airway obstruction-induced hypoxic vasoconstriction and that caused by direct pulmonary arterial obstruction as in acute pulmonary thromboembolism (PTE). The fusion images showed better correlation of lung perfusion distribution with lung CT attenuation changes at lung mosaic CT attenuation (MCA) compared with regional ventilation in the wide-spectral lung disorders, indicating that lung heterogeneous perfusion distribution may be a dominant mechanism of MCA on CT. SPECT-CT angiography fusion images revealed occasional dissociation between lung perfusion defects and intravascular clots in acute PTE, indicating the importance of assessment of actual effect of intravascular colts on peripheral lung perfusion. Perfusion SPECT-CT fusion images revealed the characteristic and preferential location of pulmonary infarction in acute PTE. The fusion images showed occasional unexpected perfusion defects in normal lung areas on CT in chronic obstructive pulmonary diseases and interstitial lung diseases, indicating the ability of perfusion SPECT superior to CT for detection of mild lesions in these disorders. The fusion images showed frequent ''steal phenomenon''-induced perfusion defects extending to the surrounding normal lung of arteriovenous fistulas and those at normal lungs on CT in hepatopulmonary syndrome. Comprehensive assessment of lung function-CT morphology on fusion images will lead to more profound understanding of lung pathophysiology in wide-spectral lung

  15. Pulmonary vascular imaging

    International Nuclear Information System (INIS)

    Fedullo, P.F.; Shure, D.

    1987-01-01

    A wide range of pulmonary vascular imaging techniques are available for the diagnostic evaluation of patients with suspected pulmonary vascular disease. The characteristics of any ideal technique would include high sensitivity and specificity, safety, simplicity, and sequential applicability. To date, no single technique meets these ideal characteristics. Conventional pulmonary angiography remains the gold standard for the diagnosis of acute thromboembolic disease despite the introduction of newer techniques such as digital subtraction angiography and magnetic resonance imaging. Improved noninvasive lower extremity venous testing methods, particularly impedance plethysmography, and ventilation-perfusion scanning can play significant roles in the noninvasive diagnosis of acute pulmonary emboli when properly applied. Ventilation-perfusion scanning may also be useful as a screening test to differentiate possible primary pulmonary hypertension from chronic thromboembolic pulmonary hypertension. And, finally, angioscopy may be a useful adjunctive technique to detect chronic thromboembolic disease and determine operability. Optimal clinical decision-making, however, will continue to require the proper interpretation of adjunctive information obtained from the less-invasive techniques, applied with an understanding of the natural history of the various forms of pulmonary vascular disease and with a knowledge of the capabilities and shortcomings of the individual techniques

  16. 201Tl myocardial imaging in patients with pulmonary hypertension

    International Nuclear Information System (INIS)

    Cohen, H.A.; Baird, M.G.; Rouleau, J.R.; Fuhrmann, C.F.; Bailey, I.K.; Summer, W.R.; Strauss, H.W.; Pitt, B.

    1976-01-01

    The appearance of the right ventricular myocardium on thallium 201 myocardial perfusion images was evaluated in patients with chronic pulmonary hypertension and compared to patients without pulmonary hypertension. Four groups of patients were studied: (1) eight normals, (2) five patients with angiographically documented coronary artery disease and normal pulmonary artery pressures, (3) ten patients with moderate to severe pulmonary parenchymal or vascular disease and documented pulmonary hypertension and (4) eight patients with chronic left ventricular dysfunction and pulmonary hypertension discovered during cardiac catheterization. The right ventricular free wall was visualized on the thallium 201 myocardial perfusion image in only one of eight normals (group 1) and in only one of the five patients with coronary artery disease (group 2) and measured 0.5 cm and 0.9 cm in thickness, respectively. In patients with documented pulmonary hypertension the right ventricle was visualized on low contrast thallium 201 myocardial perfusion image in all patients. The apparent right ventricular free wall thickness measured from the ungated thallium 201 myocardial perfusion images was 1.7 +- 0.3 cm in group 3 and 1.5 +- 0.2 cm in group 4. Right ventricular hypertrophy was detected by electrocardiography in only five of ten patients in group 3 and only one of eight patients in group 4. Thallium 201 myocardial perfusion imaging appears to be a useful technique for assessing the effects of chronic pulmonary hypertension on the right ventricular myocardium

  17. Quantitative analysis of pulmonary perfusion using time-resolved parallel 3D MRI - initial results

    International Nuclear Information System (INIS)

    Fink, C.; Buhmann, R.; Plathow, C.; Puderbach, M.; Kauczor, H.U.; Risse, F.; Ley, S.; Meyer, F.J.

    2004-01-01

    Purpose: to assess the use of time-resolved parallel 3D MRI for a quantitative analysis of pulmonary perfusion in patients with cardiopulmonary disease. Materials and methods: eight patients with pulmonary embolism or pulmonary hypertension were examined with a time-resolved 3D gradient echo pulse sequence with parallel imaging techniques (FLASH 3D, TE/TR: 0.8/1.9 ms; flip angle: 40 ; GRAPPA). A quantitative perfusion analysis based on indicator dilution theory was performed using a dedicated software. Results: patients with pulmonary embolism or chronic thromboembolic pulmonary hypertension revealed characteristic wedge-shaped perfusion defects at perfusion MRI. They were characterized by a decreased pulmonary blood flow (PBF) and pulmonary blood volume (PBV) and increased mean transit time (MTT). Patients with primary pulmonary hypertension or eisenmenger syndrome showed a more homogeneous perfusion pattern. The mean MTT of all patients was 3.3 - 4.7 s. The mean PBF and PBV showed a broader interindividual variation (PBF: 104-322 ml/100 ml/min; PBV: 8 - 21 ml/100 ml). Conclusion: time-resolved parallel 3D MRI allows at least a semi-quantitative assessment of lung perfusion. Future studies will have to assess the clinical value of this quantitative information for the diagnosis and management of cardiopulmonary disease. (orig.) [de

  18. Accuracy and feasibility of dynamic contrast-enhanced 3D MR imaging in the assessment of lung perfusion: comparison with Tc-99 MAA perfusion scintigraphy

    International Nuclear Information System (INIS)

    Yilmaz, E.; Akkoclu, A.; Degirmenci, B.; Cooper, R.A.; Sengun, B.; Gulcu, A.; Osma, E.; Ucan, E.S.

    2005-01-01

    AIM: The aim of this study was to correlate findings of perfusion magnetic resonance imaging (MRI) and perfusion scintigraphy in cases where there was a suspicion of abnormal pulmonary vasculature, and to evaluate the usefulness of MRI in the detection of perfusion deficits of the lung. METHODS: In all, 17 patients with suspected abnormality of the pulmonary vasculature underwent dynamic contrast-enhanced MRI. T1-weighted 3D fast-field echo pulse sequences were obtained (TR/TE 3.3/1.58 ms; flip angle 30 deg ; slice thickness 12 to 15 mm). The dynamic study was acquired in the coronal plane following administration of 0.1 mmol/kg gadopentetate dimeglumine. A total of 8 to 10 sections repeated 20 to 25 times at intervals of 1 s were performed. Perfusion lung scintigraphy was carried out a maximum of 48 h before the MR examination in all cases. Two radiologists, who were blinded to the clinical data and results of other imaging methods, reviewed all coronal sections. MR perfusion images were independently assessed in terms of segmental or lobar perfusion defects in the 85 lobes of the 17 individuals, and the findings were compared with the results of scintigraphy. RESULTS: Of the 17 patients, 8 were found to have pulmonary emboli, 2 chronic obstructive pulmonary disease with emphysema, 2 bullous emphysema, 2 Takayasu arteritis and 1 had a hypoplastic pulmonary artery. Pulmonary perfusion was completely normal in 2 cases. In 35 lobes, perfusion defects were detected using both methods, in 4 with MR alone and in 9 only with scintigraphy. There was good agreement between MRI and scintigraphy findings (kappa=0.695). CONCLUSION: Pulmonary perfusion MRI is a new alternative to scintigraphy in the evaluation of pulmonary perfusion for various lung disorders. In addition, this technique allows measurement and quantification of pulmonary perfusion abnormalities

  19. Fusion imaging of computed tomographic pulmonary angiography and SPECT ventilation/perfusion scintigraphy: initial experience and potential benefit

    International Nuclear Information System (INIS)

    Harris, Benjamin; Bailey, Dale; Roach, Paul; Bailey, Elizabeth; King, Gregory

    2007-01-01

    The objective of this study was to examine the feasibility of fusing ventilation and perfusion data from single-photon emission computed tomography (SPECT) ventilation perfusion (V/Q) scintigraphy together with computed tomographic pulmonary angiography (CTPA) data. We sought to determine the accuracy of this fusion process. In addition, we correlated the findings of this technique with the final clinical diagnosis. Thirty consecutive patients (17 female, 13 male) who had undergone both CTPA and SPECT V/Q scintigraphy during their admission for investigation of potential pulmonary embolism were identified retrospectively. Image datasets from these two modalities were co-registered and fused using commercial software. Accuracy of the fusion process was determined subjectively by correlation between modalities of the anatomical boundaries and co-existent pleuro-parenchymal abnormalities. In all 30 cases, SPECT V/Q images were accurately fused with CTPA images. An automated registration algorithm was sufficient alone in 23 cases (77%). Additional linear z-axis scaling was applied in seven cases. There was accurate topographical co-localisation of vascular, parenchymal and pleural disease on the fused images. Nine patients who had positive CTPA performed as an initial investigation had co-localised perfusion defects on the subsequent fused CTPA/SPECT images. Three of the 11 V/Q scans initially reported as intermediate could be reinterpreted as low probability owing to co-localisation of defects with parenchymal or pleural pathology. Accurate fusion of SPECT V/Q scintigraphy to CTPA images is possible. This technique may be clinically useful in patients who have non-diagnostic initial investigations or in whom corroborative imaging is sought. (orig.)

  20. Ventilation/perfusion SPECT or SPECT/CT for lung function imaging in patients with pulmonary emphysema?

    Science.gov (United States)

    Froeling, Vera; Heimann, Uwe; Huebner, Ralf-Harto; Kroencke, Thomas J; Maurer, Martin H; Doellinger, Felix; Geisel, Dominik; Hamm, Bernd; Brenner, Winfried; Schreiter, Nils F

    2015-07-01

    To evaluate the utility of attenuation correction (AC) of V/P SPECT images for patients with pulmonary emphysema. Twenty-one patients (mean age 67.6 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. AC/non-AC V/P SPECT images were compared visually and semiquantitatively. Visual comparison of AC/non-AC images was based on a 5-point likert scale. Semiquantitative comparison assessed absolute counts per lung (aCpLu) and lung lobe (aCpLo) for AC/non-AC images using software-based analysis; percentage counts (PC = (aCpLo/aCpLu) × 100) were calculated. Correlation between AC/non-AC V/P SPECT images was analyzed using Spearman's rho correlation coefficient; differences were tested for significance with the Wilcoxon rank sum test. Visual analysis revealed high conformity for AC and non-AC V/P SPECT images. Semiquantitative analysis of PC in AC/non-AC images had an excellent correlation and showed no significant differences in perfusion (ρ = 0.986) or ventilation (ρ = 0.979, p = 0.809) SPECT/CT images. AC of V/P SPECT images for lung lobe-based function imaging in patients with pulmonary emphysema do not improve visual or semiquantitative image analysis.

  1. Lung imaging in pulmonary disease

    International Nuclear Information System (INIS)

    Taplin, G.V.; Chopra, S.K.

    1976-01-01

    Although it has been recognized for several years that chronic obstructive pulmonary disease (COPD) can cause lung perfusion defects which may simulate pulmonary embolism, relatively little use has been made of either the radioxenon or the radioaerosol inhalation lung imaging procedures until the last few years as a means of distinguishing pulmonary embolism (P.E.) from COPD is reported. Recent experience is reported with the use of both of these procedures in comparison with pulmonary function tests for the early detection of COPD in population studies and also in P.E. suspects. Equal emphasis is given to simultaneous aerosol ventilation-perfusion (V/P) imaging in the differential diagnosis of P.E. Finally, this paper is concerned with new developments in regional lung diffusion imaging following the inhalation of radioactive gases and rapidly absorbed radioaerosols. Their experimental basis is presented and their potential clinical applications in pulmonary embolism are discussed. As a result of these investigations, a functional (V/P) diagnosis of pulmonary embolism in patients may be possible in the near future with a sequential radioaerosol inhalation procedure alone

  2. Perfusion study in the pulmonary hilar region by SPECT

    International Nuclear Information System (INIS)

    Satoh, Katashi; Tanabe, Masatada; Kawase, Yoshiro

    1990-01-01

    Alveoli in the hilar region comprise the peripheral area containing daughter branches from subsegmental or one more divisional peripheral bronchi. Pulmonary perfusion in hilar region was examined by SPECT (single photon emission CT) in ten normal volunteers. ROI (region of interest) in the axial images were set in the hilar region, the upper, middle and lower lung fields with 10.8 mm thickness. Counts/one pixel (C/P) were calculated in these ROI. There was a tendency of C/P increase from upper to lower lung field. And there were no significant differences in C/P increase between hilar region and other axial fields. In the chronic obstructive pulmonary diseases, however, ventilation studies in the previous reports using Xe dynamic CT or PET (positron emission tomography) showed differences between outer region and hilar region. This method will be expected to evaluate the pulmonary perfusion not only in the whole lung but in different lung areas, including the hilar region in the chronic obstructive pulmonary diseases. (author)

  3. Preliminary studies of pulmonary perfusion scanning in patients with pulmonary hypertension

    International Nuclear Information System (INIS)

    Shi Rongfang; Liu Xiujie; Wang Yanqun

    1986-01-01

    A comparative analysis of pulmonary perfusion scanning through cardiac catheterization of 57 patients including 32 patients with congenital heart disease, 8 patients with chronic pulmonary thromboembolism and 7 patients with primary pulmonary hypertension is reported. The lung scintigram obtained with In-113m or Tc-99m-MAA represents the distribution of pulmonary blood. It has been found that the lung scintigram was abnormal in patients of congenital heart disease with pulmonary hypertension (i. e. pulmonary artery pressure between 41-80 mmHg) and the extent of radoiactive regional defects is proportional to the level of pulmonary hypertension. The results of the analysis indicated that pulmonary perfusion scanning being a noninvasive technique would be a useful method in evaluating the level of pulmonary hypertension in patients with left to right shunt before and after surgical operation

  4. Perfusion lung scanning: differentiation of primary from thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Lisbona, R.; Kreisman, H.; Novales-Diaz, J.; Derbekyan, V.

    1985-01-01

    Of eight patients with pulmonary arterial hypertension, final diagnosis established by autopsy or angiography, four had primary hypertension and four hypertension from thromboembolism. The perfusion lung scan was distinctly different in the two groups. The lung scan in primary pulmonary hypertension was associated with nonsegmental, patchy defects of perfusion, while in thromboembolic hypertensives it was characterized by segmental and/or lobar defects of perfusion with or without subsegmental defects. The perfusion lung scan is a valuable, noninvasive study in the evaluation of the patient with pulmonary hypertension of undetermined cause and in the exclusion of occult large-vessel pulmonary thromboembolism

  5. Chronic thromboembolic pulmonary hypertension - assessment by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kreitner, Karl-Friedrich; Kunz, R.P.; Oberholzer, Katja; Neeb, Daniel; Gast, Klaus K.; Dueber, Christoph [Johannes-Gutenberg-University, Department of Diagnostic and Interventional Radiology, Mainz (Germany); Ley, Sebastian [Johannes-Gutenberg-University, Department of Diagnostic and Interventional Radiology, Mainz (Germany); German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Heussel, Claus-Peter [Johannes-Gutenberg-University, Department of Diagnostic and Interventional Radiology, Mainz (Germany); Chest Clinic at University of Heidelberg, Department of Radiology, Heidelberg (Germany); Eberle, Balthasar [Johannes-Gutenberg-University, Department of Anesthesiology, Mainz (Germany); Inselspital, Department of Anesthesiology, Bern (Switzerland); Mayer, Eckhard [Johannes-Gutenberg-University, Department of Heart, Thorax and Vascular Surgery, Mainz (Germany); Kauczor, Hans-Ulrich [German Cancer Research Center, Department of Radiology, Heidelberg (Germany)

    2007-01-15

    Chronic thromboembolic pulmonary hypertension (CTEPH) is a severe disease that has been ignored for a long time. However, with the development of improved therapeutic modalities, cardiologists and thoracic surgeons have shown increasing interest in the diagnostic work-up of this entity. The diagnosis and management of chronic thromboembolic pulmonary hypertension require a multidisciplinary approach involving the specialties of pulmonary medicine, cardiology, radiology, anesthesiology and thoracic surgery. With this approach, pulmonary endarterectomy (PEA) can be performed with an acceptable mortality rate. This review article describes the developments in magnetic resonance (MR) imaging techniques for the diagnosis of chronic thromboembolic pulmonary hypertension. Techniques include contrast-enhanced MR angiography (ce-MRA), MR perfusion imaging, phase-contrast imaging of the great vessels, cine imaging of the heart and combined perfusion-ventilation MR imaging with hyperpolarized noble gases. It is anticipated that MR imaging will play a central role in the initial diagnosis and follow-up of patients with CTEPH. (orig.)

  6. Chronic thromboembolic pulmonary hypertension - assessment by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kreitner, Karl-Friedrich; Kunz, R.P.; Oberholzer, Katja; Neeb, Daniel; Gast, Klaus K.; Dueber, Christoph; Ley, Sebastian; Heussel, Claus-Peter; Eberle, Balthasar; Mayer, Eckhard; Kauczor, Hans-Ulrich

    2007-01-01

    Chronic thromboembolic pulmonary hypertension (CTEPH) is a severe disease that has been ignored for a long time. However, with the development of improved therapeutic modalities, cardiologists and thoracic surgeons have shown increasing interest in the diagnostic work-up of this entity. The diagnosis and management of chronic thromboembolic pulmonary hypertension require a multidisciplinary approach involving the specialties of pulmonary medicine, cardiology, radiology, anesthesiology and thoracic surgery. With this approach, pulmonary endarterectomy (PEA) can be performed with an acceptable mortality rate. This review article describes the developments in magnetic resonance (MR) imaging techniques for the diagnosis of chronic thromboembolic pulmonary hypertension. Techniques include contrast-enhanced MR angiography (ce-MRA), MR perfusion imaging, phase-contrast imaging of the great vessels, cine imaging of the heart and combined perfusion-ventilation MR imaging with hyperpolarized noble gases. It is anticipated that MR imaging will play a central role in the initial diagnosis and follow-up of patients with CTEPH. (orig.)

  7. Krypton 81m and xenon 133 for complementary ventilation imaging in pulmonary perfusion studies: a clinical comparison. Chapter 12

    International Nuclear Information System (INIS)

    Weber, P.M.; Remedios, L.V.dos.

    1978-01-01

    Twenty-four patients with suspected pulmonary embolism were studied to determine the relative usefulness of 133 Xe and 81 Krsup(m) as indicators of pulmonary ventilation in complementing perfusion studies. In most cases, where krypton produced results superior to xenon, this could be attributed to better resolution of the 190 keV photon and to the fact that multiple views could be obtained, with each view paired precisely with a corresponding perfusion image, the direct result of the ease of use of krypton and its short 13 second half-life. This was well demonstrated in both of the patients with presumed pulmonary embolism and co-existing other pulmonary disease in which the results with xenon and krypton differed. In each case the mis-match was obscured by closely related areas of delayed xenon wash-out. In those patients where xenon demonstrated greater sensitivity in identifying areas of pulmonary disease, the lesions noted on wash-out appeared as areas of positive activity, while with krypton the defects were always photogenic and, when small probably obscured by scatter from adjacent normal activity. In the patient who might have been improperly categorized as a mis-match without the krypton study, the xenon study may have been normal because of inadequate equilibration time. (author)

  8. Dynamic (4D) CT perfusion offers simultaneous functional and anatomical insights into pulmonary embolism resolution

    Energy Technology Data Exchange (ETDEWEB)

    Mirsadraee, Saeed, E-mail: saeed.mirsadraee@ed.ac.uk [Clinical Research Imaging Centre, Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom); Reid, John H.; Connell, Martin [Clinical Research Imaging Centre, Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom); MacNee, William; Hirani, Nikhil [The Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom); Murchison, John T. [Department of Radiology, Royal Infirmary of Edinburgh, 51 Little France Crescent, Edinburgh EH16 4SA (United Kingdom); Beek, Edwin J. van [Clinical Research Imaging Centre, Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom)

    2016-10-15

    Objective: Resolution and long-term functional effects of pulmonary emboli are unpredictable. This study was carried out to assess persisting vascular bed perfusion abnormalities and resolution of arterial thrombus in patients with recent pulmonary embolism (PE). Methods and materials: 26 Patients were prospectively evaluated by dynamic (4D) contrast enhanced CT perfusion dynamic pulmonary CT perfusion. Intermittent volume imaging was performed every 1.5–1.7 s during breath-hold and perfusion values were calculated by maximum-slope technique. Thrombus load (modified Miller score; MMS) and ventricular diameter were determined. Perfusion maps were visually scored and correlated with residual endoluminal filling defects. Results: The mean initial thrombus load was 13.1 ± 4.6 MMS (3–16), and 1.2 ± 2.1 MMS (0–8) at follow up. From the 24 CTPs with diagnostic quality perfusion studies, normal perfusion was observed in 7 (29%), and mildly-severely abnormal in 17 (71%). In 15 patients with no residual thrombus on follow up CTPA, normal perfusion was observed in 6, and abnormal perfusion in 9. Perfusion was abnormal in all patients with residual thrombus on follow up CTPA. Pulmonary perfusion changes were classified as reduced (n = 4), delayed (systemic circulation pattern; n = 5), and absent (no-flow; n = 5). The right ventricle was dilated in 12/25 (48%) at presentation, and normal in all 26 follow up scans. Weak correlation was found between initial ventricular dilatation and perfusion abnormality at follow up (r = 0.15). Conclusions: Most patients had substantial perfusion abnormality at 3–6 months post PE. Abnormal perfusion patterns were frequently observed in patients and in regions with no corresponding evidence of residual thrombus on CTPA. Some defects exhibit delayed, presumed systemic, enhancement (which we have termed ‘stunned’ lung). CT perfusion provides combined anatomical and functional information about PE resolution.

  9. MRI methods for pulmonary ventilation and perfusion imaging; Methoden der MRT zur Ventilations- und Perfusionsbildgebung der Lunge

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, G. [Universitaetsspital Basel, Klinik fuer Radiologie und Nuklearmedizin, Basel (Switzerland); Bauman, G. [Universitaetsspital Basel, Klinik fuer Radiologie und Nuklearmedizin - Radiologische Physik, Basel (Switzerland)

    2016-02-15

    Separate assessment of respiratory mechanics, gas exchange and pulmonary circulation is essential for the diagnosis and therapy of pulmonary diseases. Due to the global character of the information obtained clinical lung function tests are often not sufficiently specific in the differential diagnosis or have a limited sensitivity in the detection of early pathological changes. The standard procedures of pulmonary imaging are computed tomography (CT) for depiction of the morphology as well as perfusion/ventilation scintigraphy and single photon emission computed tomography (SPECT) for functional assessment. Magnetic resonance imaging (MRI) with hyperpolarized gases, O{sub 2}-enhanced MRI, MRI with fluorinated gases and Fourier decomposition MRI (FD-MRI) are available for assessment of pulmonary ventilation. For assessment of pulmonary perfusion dynamic contrast-enhanced MRI (DCE-MRI), arterial spin labeling (ASL) and FD-MRI can be used. Imaging provides a more precise insight into the pathophysiology of pulmonary function on a regional level. The advantages of MRI are a lack of ionizing radiation, which allows a protective acquisition of dynamic data as well as the high number of available contrasts and therefore accessible lung function parameters. Sufficient clinical data exist only for certain applications of DCE-MRI. For the other techniques, only feasibility studies and case series of different sizes are available. The clinical applicability of hyperpolarized gases is limited for technical reasons. The clinical application of the techniques described, except for DCE-MRI, should be restricted to scientific studies. (orig.) [German] Die separate Beurteilung von Atemmechanik, Gasaustauschprozessen und Lungenzirkulation ist wesentlich fuer die Diagnose und Therapie von Lungenerkrankungen. Klinische Lungenfunktionstests sind aufgrund ihrer zumeist nur globalen Aussage oft nicht hinreichend spezifisch in der Differenzialdiagnostik oder eingeschraenkt sensitiv bei der

  10. Solitary pulmonary nodules: Comparison of dynamic first-pass contrast-enhanced perfusion area-detector CT, dynamic first-pass contrast-enhanced MR imaging, and FDG PET/CT.

    Science.gov (United States)

    Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Seki, Shinichiro; Tsubakimoto, Maho; Fujisawa, Yasuko; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Sugimura, Kazuro

    2015-02-01

    To prospectively compare the capabilities of dynamic perfusion area-detector computed tomography (CT), dynamic magnetic resonance (MR) imaging, and positron emission tomography (PET) combined with CT (PET/CT) with use of fluorine 18 fluorodeoxyglucose (FDG) for the diagnosis of solitary pulmonary nodules. The institutional review board approved this study, and written informed consent was obtained from each subject. A total of 198 consecutive patients with 218 nodules prospectively underwent dynamic perfusion area-detector CT, dynamic MR imaging, FDG PET/CT, and microbacterial and/or pathologic examinations. Nodules were classified into three groups: malignant nodules (n = 133) and benign nodules with low (n = 53) or high (n = 32) biologic activity. Total perfusion was determined with dual-input maximum slope models at area-detector CT, maximum and slope of enhancement ratio at MR imaging, and maximum standardized uptake value (SUVmax) at PET/CT. Next, all indexes for malignant and benign nodules were compared with the Tukey honest significant difference test. Then, receiver operating characteristic analysis was performed for each index. Finally, sensitivity, specificity, and accuracy were compared with the McNemar test. All indexes showed significant differences between malignant nodules and benign nodules with low biologic activity (P Dynamic perfusion area-detector CT is more specific and accurate than dynamic MR imaging and FDG PET/CT in the diagnosis of solitary pulmonary nodules in routine clinical practice. © RSNA, 2014.

  11. Treatment Effect of Balloon Pulmonary Angioplasty in Chronic Thromboembolic Pulmonary Hypertension Quantified by Automatic Comparative Imaging in Computed Tomography Pulmonary Angiography.

    Science.gov (United States)

    Zhai, Zhiwei; Ota, Hideki; Staring, Marius; Stolk, Jan; Sugimura, Koichiro; Takase, Kei; Stoel, Berend C

    2018-05-01

    Balloon pulmonary angioplasty (BPA) in patients with inoperable chronic thromboembolic pulmonary hypertension (CTEPH) can have variable outcomes. To gain more insight into this variation, we designed a method for visualizing and quantifying changes in pulmonary perfusion by automatically comparing computed tomography (CT) pulmonary angiography before and after BPA treatment. We validated these quantifications of perfusion changes against hemodynamic changes measured with right-sided heart catheterization. We studied 14 consecutive CTEPH patients (12 women; age, 70.5 ± 24), who underwent CT pulmonary angiography and right-sided heart catheterization, before and after BPA. Posttreatment images were registered to pretreatment CT scans (using the Elastix toolbox) to obtain corresponding locations. Pulmonary vascular trees and their centerlines were detected using a graph cuts method and a distance transform method, respectively. Areas distal from vessels were defined as pulmonary parenchyma. Subsequently, the density changes within the vascular centerlines and parenchymal areas were calculated and corrected for inspiration level differences. For visualization, the densitometric changes were displayed in color-coded overlays. For quantification, the median and interquartile range of the density changes in the vascular and parenchymal areas (ΔVD and ΔPD) were calculated. The recorded changes in hemodynamic parameters, including changes in systolic, diastolic, and mean pulmonary artery pressure (ΔsPAP, ΔdPAP, and ΔmPAP, respectively) and vascular resistance (ΔPVR), were used as reference assessments of the treatment effect. Spearman correlation coefficients were employed to investigate the correlations between changes in perfusion and hemodynamic changes. Comparative imaging maps showed distinct patterns in perfusion changes among patients. Within pulmonary vessels, the interquartile range of ΔVD correlated significantly with ΔsPAP (R = -0.58, P = 0.03),

  12. Correlation of pulmonary perfusion volume analysis with pulmonary function in emphysema

    International Nuclear Information System (INIS)

    Kaneta, Tomohiro; Yamazaki, Tetsuro; Takai, Yoshihiro; Takahashi, Shoki; Yamada, Shogo; Maruoka, Shin; Abe, Yoetsu

    2000-01-01

    Pulmonary perfusion single photon emission tomography with 99m Tc MAA was performed on 13 pulmonary emphysema patients and 6 controls. We calculated perfusion volume with lower 10%, 20%, 30%, 40% and 50% of the highest counts/boxels in the lung cut-off. And perfusion index (PI) was defined as follows; PI=((A% cut-off volume)-(B% cut-off volume))/(A% cut-off volume); A and B take 10 to 50, A 1 , FEV 1 %, VC, VC%, FVC, FVC%, PaO 2 and PaCO 2 ) was examined. There were significant correlation between every PI and FEV 1 or FEV 1 % (p 1 (r=0.680) and FEV 1 % (r=0.830). And the PI showed an increasing tendency along with the rise of the emphysema severity. The PI may have the clinical utility of the evaluation of pulmonary function. Moreover, we showed the lung CT painted the area where the uptake counts/boxels was more than 10% and less than 40% of the highest counts/boxels. This makes it easy to understand the severe emphysematous area. (author)

  13. Added value of lung perfused blood volume images using dual-energy CT for assessment of acute pulmonary embolism

    International Nuclear Information System (INIS)

    Okada, Munemasa; Kunihiro, Yoshie; Nakashima, Yoshiteru; Nomura, Takafumi; Kudomi, Shohei; Yonezawa, Teppei; Suga, Kazuyoshi; Matsunaga, Naofumi

    2015-01-01

    Purpose: To investigate the added value of lung perfused blood volume (LPBV) using dual-energy CT for the evaluation of intrapulmonary clot (IPC) in patients suspected of having acute pulmonary embolism (PE). Materials and methods: Institutional review board approval was obtained for this retrospective study. Eighty-three patients suspected of having PE who underwent CT pulmonary angiography (CTPA) using a dual-energy technique were enrolled in this study. Two radiologists who were blinded retrospectively and independently reviewed CTPA images alone and the combined images with color-coded LPBV over a 4-week interval, and two separate sessions were performed with a one-month interval. Inter- and intraobserver variability and diagnostic accuracy were evaluated for each reviewer with receiver operating characteristic (ROC) curve analysis. Results: Values for inter- and intraobserver agreement, respectively, were better for CTPA combined with LPBV (ICC = 0.847 and 0.937) than CTPA alone (ICC = 0.748 and 0.861). For both readers, diagnostic accuracy (area under the ROC curve [A z ]) were also superior, when CTPA alone (A z = 0.888 [reader 1] and 0.912 [reader 2]) was compared with that after the combination with LPBV images (A z = 0.966 [reader 1] and 0.959 [reader 2]) (p < 0.001). However, A z values of both images might not have significant difference in statistics, because A z value of CTPA alone was high and 95% confidence intervals overlapped in both images. Conclusion: Addition of dual-energy perfusion CT to CTPA improves detection of peripheral IPCs with better interobserver agreement

  14. An application of semiquantitative analysis of pulmonary scintigraphy to pulmonary tuberculosis sequelae

    International Nuclear Information System (INIS)

    Uchida, Kou; Miyasaka, Takashi; Nakayama, Hiroyuki; Suganuma, Yasuaki; Sim, Jae-Joon; Takahashi, Hideki; Takano, Masaaki; Kawata, Kanemitsu.

    1996-01-01

    We performed ventilation-perfusion scintigraphy in 13 patients with pulmonary tuberculosis sequelae and 21 with chronic obstructive pulmonary disease. We used 99m Tc-MAA for perfusion scintigram and 133 Xe gas for ventilation scintigram. We added the radioactivities during the rebreathing phase of the ventilation scintigram to make a computerized image of the lung volume. Regions of interest (ROIs) were derived from radioactivities on each image. ROIs included each whole lung on lung volume (L) image and areas where radioactivity was greater than 70% of the highest radioactivity on perfusion (P70) image. We counted the area of ROIs on L and P70, and used the ratio of perfusion to lung volume (P70/L) as a parameter of pulmonary perfusion. P70/L in patients with pulmonary tuberculosis sequelae was significantly higher than that in those with COPD. This suggested that the area of high pulmonary perfusion is larger in the patients with pulmonary tuberculosis sequelae as compared with those with COPD. (author)

  15. Pulmonary artery perfusion versus no perfusion during cardiopulmonary bypass for open heart surgery in adults

    DEFF Research Database (Denmark)

    Buggeskov, Katrine B; Grønlykke, Lars; Risom, Emilie C

    2018-01-01

    BACKGROUND: Available evidence has been inconclusive on whether pulmonary artery perfusion during cardiopulmonary bypass (CPB) is associated with decreased or increased mortality, pulmonary events, and serious adverse events (SAEs) after open heart surgery. To our knowledge, no previous systematic...... handsearched retrieved study reports and scanned citations of included studies and relevant reviews to ensure that no relevant trials were missed. We searched for ongoing trials and unpublished trials in the World Health Organization International Clinical Trials Registry Platform (ICTRP) and at clinicaltrials......). We used GRADE principles to assess the quality of evidence. MAIN RESULTS: We included in this review four RCTs (210 participants) reporting relevant outcomes. Investigators randomly assigned participants to pulmonary artery perfusion with blood versus no perfusion during CPB. Only one trial included...

  16. Assessment of perfusion pattern and extent of perfusion defect on dual-energy CT angiography: Correlation between the causes of pulmonary hypertension and vascular parameters

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Young [Dept. of Radiology, Chonbuk National University Medical School and Hospital, Research Institute of Clinical Medicine, Jeonju (Korea, Republic of); Seo, Joon Beom; Oh, Sang Young; Lee, Choong Wook; Lee, Sang Min [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Hwang, Hye Jeon [Dept. of Radiology, Hallym University College of Medicine, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Lee, Young Kyung [Dept. of Radiology, Seoul Medical Center, Seoul (Korea, Republic of)

    2014-04-15

    To assess perfusion patterns on a dual-energy pulmonary CT angiography (DECTA) of pulmonary hypertension (PHT) with variable causes and to assess whether the extent of perfusion defect can be used in the severity assessment of PHT. Between March 2007 and February 2011, DECTA scans of 62 consecutive patients (24 men, 38 women; mean age, 58.5 ± 17.3 [standard deviation] years; range, 19-87 years) with PHT were retrospectively included with following inclusion criteria; 1) absence of acute pulmonary thromboembolism, 2) maximal velocity of tricuspid regurgitation jet (TR Vmax) above 3 m/s on echocardiography performed within one week of the DECTA study. Perfusion patterns of iodine map were divided into normal (NL), diffuse heterogeneously decreased (DH), multifocal geographic and multiple peripheral wedging patterns. The extent of perfusion defects (PD), the diameter of main pulmonary artery (MPA) and the ratio of ascending aorta diameter/MPA (aortopulmonary ratio, APR) were measured. Pearson correlation analysis was performed between TR Vmax on echocardiography and CT imaging parameters. Common perfusion patterns of primary PHT were DH (n = 15) and NL (n = 12). The perfusion patterns of secondary PHT were variable. On the correlation analysis, in primary PHT, TR Vmax significantly correlated with PD, MPA and APR (r = 0.52, r = 0.40, r = -0.50, respectively, all p < 0.05). In secondary PHT, TR Vmax significantly correlated with PD and MPA (r = 0.38, r = 0.53, respectively, all p < 0.05). Different perfusion patterns are observed on DECTA of PHT according to the causes. PD and MPA are significantly correlated with the TR Vmax.

  17. Assessment of perfusion pattern and extent of perfusion defect on dual-energy CT angiography: Correlation between the causes of pulmonary hypertension and vascular parameters

    International Nuclear Information System (INIS)

    Kim, Eun Young; Seo, Joon Beom; Oh, Sang Young; Lee, Choong Wook; Lee, Sang Min; Hwang, Hye Jeon; Lee, Young Kyung

    2014-01-01

    To assess perfusion patterns on a dual-energy pulmonary CT angiography (DECTA) of pulmonary hypertension (PHT) with variable causes and to assess whether the extent of perfusion defect can be used in the severity assessment of PHT. Between March 2007 and February 2011, DECTA scans of 62 consecutive patients (24 men, 38 women; mean age, 58.5 ± 17.3 [standard deviation] years; range, 19-87 years) with PHT were retrospectively included with following inclusion criteria; 1) absence of acute pulmonary thromboembolism, 2) maximal velocity of tricuspid regurgitation jet (TR Vmax) above 3 m/s on echocardiography performed within one week of the DECTA study. Perfusion patterns of iodine map were divided into normal (NL), diffuse heterogeneously decreased (DH), multifocal geographic and multiple peripheral wedging patterns. The extent of perfusion defects (PD), the diameter of main pulmonary artery (MPA) and the ratio of ascending aorta diameter/MPA (aortopulmonary ratio, APR) were measured. Pearson correlation analysis was performed between TR Vmax on echocardiography and CT imaging parameters. Common perfusion patterns of primary PHT were DH (n = 15) and NL (n = 12). The perfusion patterns of secondary PHT were variable. On the correlation analysis, in primary PHT, TR Vmax significantly correlated with PD, MPA and APR (r = 0.52, r = 0.40, r = -0.50, respectively, all p < 0.05). In secondary PHT, TR Vmax significantly correlated with PD and MPA (r = 0.38, r = 0.53, respectively, all p < 0.05). Different perfusion patterns are observed on DECTA of PHT according to the causes. PD and MPA are significantly correlated with the TR Vmax.

  18. A pilot trial on pulmonary emphysema quantification and perfusion mapping in a single-step using contrast-enhanced dual-energy computed tomography.

    Science.gov (United States)

    Lee, Choong Wook; Seo, Joon Beom; Lee, Youngjoo; Chae, Eun Jin; Kim, Namkug; Lee, Hyun Joo; Hwang, Hye Jeon; Lim, Chae-Hun

    2012-01-01

    To know whether contrast-enhanced dual-energy computed tomography angiography (DECTA) can be used for simultaneous assessment of emphysema quantification and regional perfusion evaluation. We assessed 27 patients who had pulmonary emphysema and no pulmonary embolism on visual assessment of CT images, among 584 consecutive patients who underwent DECTA for the evaluation of pulmonary embolism. Virtual noncontrast (VNC) images were generated by modifying the "Liver VNC" application in a dedicated workstation. Using in-house software, the low-attenuation area below 950HU (LAA950), the 15th percentile attenuation (15pctlVNC) and the mean lung attenuation (MeanVNC) were calculated. The "Lung PBV" application was used to assess perfusion, and the low-iodine area below 5HU (LIA5), the 15th percentile iodine (15pctlIodine), and the mean iodine value (MeanIodine) were calculated from iodine map images. The correlation between VNC parameters and pulmonary function test data (available in 22 patients) and the correlation between VNC and iodine map parameters (all included 27 patients) were assessed. Color-coded map of VNC image were compared with iodine map images for the evaluation of regional heterogeneity. We observed moderate correlations between LAA950 and predicted %FEV1 (rs = -0.47, P VNC images. We observed moderate correlations between quantitative parameters on VNC images and pulmonary function test data, and also observed moderate correlations between the severity of parenchymal destruction, as determined from VNC images, and perfusion status, as determined from iodine maps. Therefore, the contrast-enhanced DECTA can be used for the emphysema quantification and regional perfusion evaluation by using the VNC images and iodine map, simultaneously.

  19. Ventilation perfusion radionuclide imaging in cryptogenic fibrosing alveolitis

    International Nuclear Information System (INIS)

    Bourke, S.J.; Hawkins, T.; Keavey, P.M.; Gascoigne, A.D.; Corris, P.A.

    1993-01-01

    There is increasing interest in ventilation perfusion (V/Q) imaging in cryptogenic fibrosing alveolitis because of the data these scans provide on the dynamic V/Q relationships in such patients undergoing single lung transplantation. We analysed the V/Q scans of 45 consecutive patients with advanced cryptogenic fibrosing alveolitis being considered for single lung transplantation. Scans were classified according to the presence, severity and degree of matching of defects in ventilation and perfusion images and the results were compared with the data obtained from lung function tests. Ventilation images showed defects in 13 (29%) and ''washout delay'' in 15 (33%) patients; 10 (22%) patients had asymmetric distribution of ventilation with one lung receiving >60% of total ventilation. Perfusion images showed normal perfusion in 8 (18%), mild defects in 18 (40%) and major defects in 19 (42%) patients. The distribution of perfusion between lungs was significantly asymmetric in 20 (45%) patients. V/Q images were matched in 15 (33%), mildly mismatched in 15 (33%) and severely mismatched in 15 (33%) patients, but the degree of V/Q mismatch did not show a relationship to KCO, PaO 2 or A-aO 2 gradient. The appearances were atypical of pulmonary embolism in eight patients. (Author)

  20. Single photon emission computed tomography study of human pulmonary perfusion: preliminary findings

    Energy Technology Data Exchange (ETDEWEB)

    Carratu, L; Sofia, M [Naples Univ. (Italy). Facolta di Medicina e Chirurgia; Salvatore, M; Muto, P; Ariemma, G [Istituto Nazionale per la Prevenzione, Lo Studio e La Cura dei Tumori Fondazione Pascale, Naples (Italy); Lopez-Majano, V [Cook County Hospital, Chicago, IL (USA). Nuclear Medicine Div.

    1984-02-01

    Single photon emission computed tomography (SPECT) was performed with /sup 99/Tcsup(m)-albumin macroaggregates to study human pulmonary perfusion in healthy subjects and patients with respiratory diseases such as chronic obstructive pulmonary disease (COPD) and lung neoplasms. The reconstructed SPECT data was displayed in coronal, transverse, sagittal plane sections and compared to conventional perfusion scans. The SPECT data gave more complicated anatomical information about the extent of damage and morphology of the pulmonary vascular bed. In healthy subjects and COPD patients, qualitative and quantitative assessment of pulmonary perfusion could be obtained from serial SPECT scans with respect to distribution and relative concentration of the injected radiopharmaceutical. Furthermore, SPECT of pulmonary perfusion has been useful in detecting the extent of damage to the pulmonary circulation. This is useful for the preoperative evaluation and staging of lung cancer.

  1. Value of chest X-ray combined with perfusion scan versus ventilation/perfusion scan in acute pulmonary embolism

    NARCIS (Netherlands)

    de Groot, M. R.; Turkstra, F.; van Marwijk Kooy, M.; Oostdijk, A. H.; van Beek, E. J.; Büller, H. R.

    2000-01-01

    The main purpose of ventilation scanning, as adjunct to perfusion lung scintigraphy, in acute pulmonary embolism is to allow for the classification of segmental perfusion defects as mismatched, which is generally accepted as proof for the presence of pulmonary embolism. We examined whether this

  2. High-resolution imaging of pulmonary ventilation and perfusion with 68Ga-VQ respiratory gated (4-D) PET/CT

    International Nuclear Information System (INIS)

    Callahan, Jason; Hofman, Michael S.; Siva, Shankar; Kron, Tomas; Schneider, Michal E.; Binns, David; Eu, Peter; Hicks, Rodney J.

    2014-01-01

    Our group has previously reported on the use of 68 Ga-ventilation/perfusion (VQ) PET/CT scanning for the diagnosis of pulmonary embolism. We describe here the acquisition methodology for 68 Ga-VQ respiratory gated (4-D) PET/CT and the effects of respiratory motion on image coregistration in VQ scanning. A prospective study was performed in 15 patients with non-small-cell lung cancer. 4-D PET and 4-D CT images were acquired using an infrared marker on the patient's abdomen as a surrogate for breathing motion following inhalation of Galligas and intravenous administration of 68 Ga-macroaggregated albumin. Images were reconstructed with phase-matched attenuation correction. The lungs were contoured on CT and PET VQ images during free-breathing (FB) and at maximum inspiration (Insp) and expiration (Exp). The similarity between PET and CT volumes was measured using the Dice coefficient (DC) comparing the following groups; (1) FB-PET/CT, (2) InspPET/InspCT, (3) ExpPET/Exp CT, and (4) FB-PET/AveCT. A repeated measures one-way ANOVA with multiple comparison Tukey tests were performed to evaluate any difference between the groups. Diaphragmatic motion in the superior-inferior direction on the 4-D CT scan was also measured. 4-D VQ scanning was successful in all patients without additional acquisition time compared to the nongated technique. The highest volume overlap was between ExpPET and ExpCT and between FB-PET and AveCT with a DC of 0.82 and 0.80 for ventilation and perfusion, respectively. This was significantly better than the DC comparing the other groups (0.78-0.79, p 68 Ga-VQ 4-D PET/CT is feasible and the blurring caused by respiratory motion is well corrected with 4-D acquisition, which principally reduces artefact at the lung bases. The images with the highest spatial overlap were the combined expiration phase or FB PET and average CT. With higher resolution than SPECT/CT, the PET/CT technique has a broad range of potential clinical applications including

  3. Demonstration of pulmonary perfusion heterogeneity induced by gravity and lung inflation using arterial spin labeling

    Energy Technology Data Exchange (ETDEWEB)

    Fan Li [Department of Radiology, ChangZheng Hospital, Second Military Medical University, Shanghai 200003 (China)], E-mail: fanli0930@163.com; Liu Shiyuan [Department of Radiology, ChangZheng Hospital, Second Military Medical University, Shanghai 200003 (China)], E-mail: fanli7938@chinaren.com; Xiao Xiangsheng [Department of Radiology, ChangZheng Hospital, Second Military Medical University, Shanghai 200003 (China)], E-mail: lizhaobin79@163.com; Sun Fei [GE Healthcare (China)], E-mail: Fei.sun@med.ge.com

    2010-02-15

    Objective: To evaluate the effect of gravity and lung inflation on pulmonary perfusion heterogeneity in human lung using an arterial spin labeling (ASL) sequence called flow sensitive alternating inversion recovery (FAIR). Materials and methods: Magnetic resonance imaging of lung perfusion using arterial spin labeling sequence was performed in supine position in ten healthy volunteers on a 1.5 T whole body scanner (GE Healthcare). Five coronal slices at an interval of 3 cm from dorsal to ventral (labeled as P3, P6, P9, P12, P15, sequently) were obtained when the volunteers performed breath holding on end expiration and the relative pulmonary blood flow (rPBF) was measured. Then, another coronal perfusion-weighted image of P3 slice was obtained on end inspiration. Tagging efficiency of pulmonary parenchyma with IR ({delta}SI), rPBF and area of the P3 slice were analyzed. Results: (1) Along the direction of gravity, a gradient was visually perceived as a vertical increase in rPBF. There were significant statistic differences in rPBF between any two coronal planes except that between P12 and P15. In supine position, regression coefficients of right and left lung were -4.98 and -5.16, respectively. This means that rPBF decreased 4.98 (right) and 5.16 (left) for each centimeter above the dorsal. No statistical difference was seen between ROIs placed along iso-gravitational plane. (2) For a same slice, there were significant statistic differences in {delta}SI, rPBF and area at different respiratory phases (P < 0.05). Greater {delta}SI and more perfusion were observed on end expiration than on end inspiration. The area was larger on end inspiration than on end expiration. Conclusion: Both gravity and respiratory phase are important determinants of pulmonary perfusion heterogeneity. FAIR is sensitive to demonstrate gravity- and respiratory phase-dependent differences in lung perfusion. Positioning the patient so that the area of interest is down-gravity and asking patient

  4. Method for imaging pulmonary arterial hypoplasia

    International Nuclear Information System (INIS)

    Triantafillou, M.

    2000-01-01

    Full text: Pulmonary hypoplasia represents an incomplete development of the lung, resulting in the reduction of distended lung volume. This is associated with small or absent number of airway divisions, alveoli, arteries and veins. Unilateral pulmonary Hypoplasia is often asymptomatic and may be demonstrated as a hypodense lung on a chest X-ray. Computer Tomography (CT) scanning would show anatomical detail and proximal vessels. Magnetic Resonance Imaging (MRI) will show no more detail than which the CT scan has already demonstrated. It is, also, difficult to visualise collateral vessels from systemic and/or bronchial vessels on both these modalities. Pulmonary Angiography would give the definitive answer, but it is time consuming and has significant risks associated with the procedure. There are high costs associated with these modalities. Nuclear Medicine Ventilation/Perfusion (V/Q) scan performed on these patients would demonstrate diminished ventilation due to reduced lung volume and absence of perfusion to the hypoplastic lung. To date, we have performed V/Q lung scan on two children in our department. Both cases demonstrate diminished ventilation with no perfusion to the hypoplastic lung. Though the gold standard is Pulmonary Angiography, V/Q scanning is cost effective, less time consuming and a non invasive procedure that can be performed as an outpatient. It is accurate as it demonstrates absent lung perfusion, confirming the patient has pulmonary arterial hypoplasia. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  5. Correlation between the Quantifiable Parameters of Whole Solitary Pulmonary Nodules Perfusion Imaging Derived with Dynamic CT and Nodules Size

    Directory of Open Access Journals (Sweden)

    Shiyuan LIU

    2009-05-01

    Full Text Available Background and objective The solitary pulmonary nodules (SPNs is one of the most common findings on chest radiographs. The blood flow patterns of the biggest single SPNs level has been studied. This assessment may be only a limited sample of the entire region of interest (ROI and is unrepresentative of the SPNs as a volume. Ideally, SPNs volume perfusion should be measured. The aim of this study is to evaluate the correlation between the quantifiableparameters of SPNs volume perfusion imaging derived with 16-slice spiral CT and 64-slice spiral CT and nodules size. Methods Sixty-five patients with SPNs (diameter≤3 cm; 42 malignant; 12 active inflammatory; 11 benign underwent multi-location dynamic contrast material-enhanced serial CT scanning mode with stable table were performed; The mean values of valid sections were calculated, as the quantifiable parameters of volume SPNs perfusion imaging derived with16-slice spiral CT and 64-slice spiral CT. The correlation between the quantifiable parameters of SPNs volume perfusion imaging derived with 16-slice spiral CT and 64-slice spiral CT and nodules size were assessed by means of linear regression analysis. Results No significant correlations were found between the nodules size and each of the peak height (PHSPN (32.15 Hu±14.55 Hu,ratio of peak height of the SPN to that of the aorta (SPN-to-A ratio(13.20±6.18%, perfusion(PSPN (29.79±19.12 mLmin-1100 g-1 and mean transit time (12.95±6.53 s (r =0.081, P =0.419; r =0.089, P =0.487; r =0.167, P =0.077; r =0.023, P =0.880. Conclusion No significant correlations were found between the quantifiable parameters of SPNs volume perfusion imaging derived with 16-slice spiral CT and 64-slice spiral CT and nodules size.

  6. Pulmonary perfusion ''without ventilation''

    International Nuclear Information System (INIS)

    Chapman, C.N.; Sziklas, J.J.; Spencer, R.P.; Rosenberg, R.J.

    1983-01-01

    An 88-yr-old man, with prior left upper lobectomy and phrenic nerve injury, had a ventilation/perfusion lung image. Both wash-in and equilibrium ventilation images showed no radioactive gas in the left lung. Nevertheless, the left lung was perfused. A similar result was obtained on a repeat study 8 days later. Delayed images, during washout, showed some radioactive gas in the left lung. Nearly absent ventilation (but continued perfusion) of that lung might have been related to altered gas dynamics brought about by the prior lobectomy, a submucosal bronchial lesion, phrenic nerve damage, and limited motion of the left part of the diaphragm. This case raises the issue of the degree of ventilation (and the phase relationship between the lungs) required for the entry of radioactive gas into a diseased lung, and the production of a ''reversed ventilation/perfusion mismatch.''

  7. MR imaging of the pulmonary vasculature - an update

    Energy Technology Data Exchange (ETDEWEB)

    Pedersen, Mark R.; Fisher, Mark T. [University of Iowa, Department of Radiology, Carver College of Medicine, Iowa City, Iowa (United States); Beek, Edwin J.R. van [University of Iowa, Department of Radiology, Carver College of Medicine, Iowa City, Iowa (United States); University of Iowa Hospitals and Clinics, JPP 3895, Department of Radiology, Iowa City, Iowa (United States)

    2006-06-15

    Although the advent of multi-detector row computed tomography (CT) angiography has been at the heart of improving the diagnostic management of pulmonary vascular disease, MR technology has also moved forward. This review outlines the current state of affairs of MR techniques for the assessment of pulmonary vascular diseases such as pulmonary hypertension, pulmonary arteritis and arteriovenous malformations. It highlights the main areas of MR angiography and MR perfusion imaging and discusses novel methods, such as non-contrast enhanced direct thrombus imaging, and will discuss its merits in the context of other diagnostic modalities. (orig.)

  8. The inhomogeneous perfusion of the solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Li Shenjiang; Xiao Xiangsheng; Liu Shiyuan; Li Chengzhou; Zhang Chenshi

    2008-01-01

    Objective: To investigate whether the perfusion of the solitary pulmonary nodules (SPNs) is homogeneous derived with 16-slice spiral CT and 64-slice spiral CT. Methods: Eight-five patients with. SPNs (diameter≤4 cm; 57 maliagnant; 15 active inflammatory; 13 benign) underwent multi- location dynamic contrast material-enhanced serial CT. One scan was obtained every 1 seconds during 11-- 41 seconds without scanning interval after injection, one scan was obtained at 90 seconds. TOSHIBA AquilionMarconi 16: The section thickness was 8.0 mm for lesions 3.0-4.0 cm, 6.0 mm for 2.0- 3.0 cm, 4.0 mm for 1.5-2.0 cm, 3.0 mm for 1.0-1.5 cm and 2.0 mm for lesions -1 ·100 g -1 , the ratios of peak height of the SPN to that of the aorta (13.58±6.41)%, (10.95±5.76)%, (13.64± 6.20)% and the mean transit times (11.61±5.74), (11.97±3.55), (13.44±3.74) s. Statistically significant differences were found among three sections in the peak height (F=5.913, P=0.003), perfusion (F=6.464,P=0.002), ratio of peak height of the SPN to that of the aorta(F=5.333,P=0.005) and mean transit time (F=3.837, P=0.023). No statistically significant differences were found among three sections in precontrast attenuation (F=0.032, P=0.968). Conclusion: The volume perfusion of the SPNs is inhomogeneous, it is suggested to evaluate blood flow patterns of the solitary pulmonary nodules with CT volume perfusion imaging. (authors)

  9. Radiospirometry and perfusion scintigraphy in cases of limited pulmonary fibrosis

    International Nuclear Information System (INIS)

    Tarkowska, A.; Smajkiewicz, L.; Szarewicz-Adamczyk, W.; Zaorska-Rajca, J.; Woytowicz, A.; Patyra, S.

    1981-01-01

    In 60 cases of limited pulmonary fibrosis radiospirometric investigation was performed using 133 Xe and a four-channel set. Perfusion scintigraphy was done as well after administration of labelled molecules. In all patients abnormalities were found in the results of both isotope methods suggesting presence of disturbances in the regional pulmonary functions. These disturbances included impairment of perfusion as well as ventilation, with evidence of obturation, increased volume of residual air, and decreased vital and total capasity of the lungs. These abnormalities occurred exclusively or most intensively in the areas corresponding to the location of the anatomical change, and in a considerable proportion of cases they were more extensive than the radiological changes. In about 40% of the patients in the contralateral lung diffuse changes of perfusion and ventilation were present, although much less intense, suggesting concomitant chronic obturative disease. The authors think that perfusion scintigraphy and radiospirometry owing to their value as a method of assessing pulmonary function are useful in cases of pulmonary fibrosis for establishing treatment methods and for evaluating disability to work. (author)

  10. Perfusion lung scintigraphy in primary pulmonary hypertension

    International Nuclear Information System (INIS)

    Ogawa, Yoji; Nishimura, Tsunehiko; Kumita, Shin-ichirou; Hayashida, Kohei; Uehara, Toshiisa; Shimonagata, Tsuyoshi; Ohno, Akira

    1991-01-01

    Fifteen cases with primary pulmonary hypertension (PPH) were classified into two groups by using the perfusion lung scan pattern. Eight cases had multiple, small, ill-defined defects (mottled pattern), and remaining seven cases had no mottled pattern. These two groups were compared with mean pulmonary arterial pressure (mean PAP), right ventricular ejection fraction (RVEF), blood gas at room air (PaO 2 ), and alveolar-arterial O 2 difference (A-aDo 2 ). The cases with mottled pattern showed a significant increase in mean PAP. There were no significant differences in RVEF, PaO 2 , and A-aDo 2 , between the groups. The survival rate of the patients with mottled pattern was significantly lower than that without mottled pattern (p<0.05). We concluded that perfusion lung scan is very useful for evaluation of the prognosis in primary pulmonary hypertension. (author)

  11. Comparative diagnostic value of pulmonary perfusion and ventilation scintigraphy and angiopneumography in pulmonary embolism

    International Nuclear Information System (INIS)

    Peltier, P.; Cesbron, J.P.; Dupas, B.; Crochet, D.; Delhumeau, J.

    1984-01-01

    Fourty-six patients suspected clinically of having a pulmonary embolism (PE) were investigated by angiopneumography (AGP) and perfusion (99m-Tc aggregates) and ventilation (99m-Tc colloid) scintigraohy (SPV Tc). Findings were assessed under blind conditions. A positive diagnosis of pulmonary embolism was made in 19 patients. The SPV Tc was considered as positive if perfusional deficiencies were greater than ventilatory defects, and this was evaluated as such in 23 cases (19 true and 4 false positives). False negatives were not observed. The 4 false positive results corresponded to scintigraphic anomalies suggestive of pulmonary emboli subsegmental in size; true positives were either subsegmental (8), segmental (6) or lobar (5). Sensitivity of the SPV Tc was therefore 100 %; its specificity, all results considered was 76 %, but was 100 % if only images of lobar or segmental lesions are considered [fr

  12. Evaluation of pulmonary hypertension and surgical therapeutic efficacy using first-pass radionuclide pulmonary perfusion imaging in patients with pulmonary hypertension of valvular heart disease

    International Nuclear Information System (INIS)

    Wang Xuemei; Shi Rongfang; Fang Wei; Wang Daoyu; Zhou Baogui; Wang Qi; Pan Shiwei

    2004-01-01

    Objective: To evaluate pulmonary hypertension (PH) and surgical therapeutic efficacy using first-pass radionuclide pulmonary perfusion imaging (FPPPI) and pulmonary perfusion imaging (PPI) in patients with PH of valvular heart disease. Methods: One hundred and sixteen patients with valvular disease were included in the study. Swan-Ganz catheterization, echocardiography, FPPPI and PPI were performed on all patients before surgery. The patients were divided into four groups. Results: 1) Correlation coefficients were 0.856, 0.503 and 0.572 (P<0.01) between lung equilibrium time (LET) by FPPPI, superior lung/low lung ratio (S/L) by PPI , systolic pulmonary arterial pressure (SPAP) from echocardiography and SPAP from the catheter manometer. 2)The sensitivity, specificity and accuracy of PAP using FPPPI measuring were 94.7%, 68.3% and 85.3%, respectively. The sensitivity, specificity and accuracy of PAP using PPI measuring were 78.8%, 52.8% and 70.7%, respectively. The sensitivity, specificity and accuracy of PAP using FPPPI plus PPI measuring were 96.4%, 72.7% and 89.7%, respectively. 3)LET by FPPPI before surgery and 5-14 d after surgery were (27.71 ± 10.85) and (20.96 ± 6.25) s, respectively (P<0.001). SPL by PPI were 1.43 ± 0.41 and 1.30 ± 0.35, respectively (P<0.001). 4) Complete improvement rates of LET in the PAP slightly risen group, moderately risen group and weightily risen group were 47.6%, 34.5% and 1/4, respectively; part improvement rates of LET for corresponding groups were 40.5%, 62.1% and 3/4, respectively (P<0.001). Complete improvement rates of SPL were 31.0%, 34.5% and 0/4, respectively; part improvement rates of SPL were 35.7%, 55.2% and 3/4, respectively (P<0.05). Complete improvement rates of LET + SPL were 57.1%, 58.6% and 1/4; part improvement rates of LET+SPL were 38.1%, 41.4% and 3/4, respectively (P<0.01). Conclusions: 1)FPPPI is better than PPI and echocardiography for evaluating PH in valvular heart disease. 2)Combined FPPPI and PPI can

  13. Quantitative pulmonary perfusion imaging at 3.0 T of 2-year-old children after congenital diaphragmatic hernia repair: initial results

    International Nuclear Information System (INIS)

    Zoellner, F.G.; Schad, L.R.; Zahn, K.; Schaible, T.; Schoenberg, S.O.; Neff, K.W.

    2012-01-01

    To investigate whether dynamic contrast-enhanced MR imaging of the lung following congenital diaphragmatic hernia repair is feasible at 3.0 T in 2-year-old children and whether associated lung hypoplasia (reflected in reduced pulmonary microcirculation) can be demonstrated in MRI. Twelve children with a mean age 2.0 ± 0.2 years after hernia repair underwent DCE-MRI at 3.0 T using a time-resolved angiography with stochastic trajectories sequence. Quantification of lung perfusion was performed using a pixel-by-pixel deconvolution approach. Six regions of interest were placed (upper, middle and lower parts of right and left lung) to assess differences in pulmonary blood flow (PBF), pulmonary blood volume (PBV) and mean transit time (MTT) while avoiding the inclusion of larger pulmonary arteries and veins. The difference in PBF and PBV between ipsilateral and contralateral lung was significant (P < 0.5). No significant differences could be detected for the MTT (P = 0.5). DCE-MRI in 2-year-old patients is feasible at 3.0 T. Reduced perfusion in the ipsilateral lung is reflected by significantly lower PBF values compared with the contralateral lung. DCE-MRI of the lung in congenital diaphragmatic hernia can help to characterise lung hypoplasia initially and in the long-term follow-up of children after diaphragmatic repair. (orig.)

  14. Imaging findings of pulmonary vascular disorders in portal hypertension

    International Nuclear Information System (INIS)

    Nagasawa, Kenichi; Takahashi, Koji; Furuse, Makoto

    2004-01-01

    The purpose of this study was to demonstrate and compare the imaging findings of hepatopulmonary syndrome and portopulmonary hypertension. We retrospectively reviewed the imaging findings of five patients with hepatopulmonary syndrome and four patients with portopulmonary hypertension. We evaluated chest radiographs, chest and abdominal computed tomography (CT) scans, 99m Tc-macroaggregated albumin (MAA) lung perfusion scans, and pulmonary angiograms. In patients with hepatopulmonary syndrome, the presence of peripheral pulmonary vascular dilatation was detected by chest radiograph, chest CT scan, and pulmonary angiogram, especially the basilar segment. 99m Tc-MAA lung perfusion scan showed extrapulmonary tracer distribution (brain, thyroid, and kidney), which revealed pulmonary right-left shunting. In patients with portopulmonary hypertension, chest radiographs and chest CT scans showed the classic findings of primary pulmonary hypertension. In patients with both disorders, extrahepatic features of portal hypertension including ascites, splenomegaly, and portosystemic collateral vessels were seen on abdominal CT. In conclusion, chest radiographs and CT in hepatopulmonary syndrome usually showed peripheral pulmonary vascular dilatation, whereas those in portopulmonary hypertension showed central pulmonary artery dilatation. The extrahepatic features of portal hypertension might be helpful for the diagnosis of both disorders. (author)

  15. Evaluation of Tl-201 lung uptake and impairment of pulmonary perfusion on scintigraphies in pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Koizumi, Tomonori; Kubo, Keishi

    2000-01-01

    Tl-201 lung uptake in 74 patients (85 lesions) and pulmonary perfusion in 105 patients were studied to evaluate clinical usefulness of Tl-201 lung uptake and perfusion lung scintigraphy in pulmonary tuberculosis, using a scintillation camera with a mini-computer system. As indices of Tl-201 lung uptake, lung (lesion) to upper mediastinum uptake ratio (L/M) and visual grading were used. L/M in pulmonary tuberculosis was 1.96±0.66, which was significantly larger than 1.04±0.24 in healthy controls and lower than that in heart diseases with left heart failure and idiopathic interstitial pneumonia, and showed no significant differences with that in acute pneumonia, pyothorax, primary lung cancer and malignant mediastinal tumor. L/M in pulmonary tuberculosis did not correlate with CRP, erythrocyte sedimentation rate, Gaffky number of sputum and body temperature. It correlated with the type of pulmonary tuberculosis according to the Gakken Classification reflecting the disease activity. It was larger in the exudative type, caseo-infiltrative one, disseminated one, one with cavity in infiltrative lesion than the fibro-caseous one. On perfusion lung scintigram, impairment of pulmonary perfusion larger than area of the entire unilateral lung was observed in 68 cases (64.8%). Area of hypoperfused lung field, which correlated with % vital capacity (r=0.60, p=0.0002) and PaO 2 (r=0.39,p=0.0024), was significantly larger in patients with silicosis and those with bilateral pleural involvements such as pleural callosity than in those with type III according to the Gakkai Classification. Most of the patients showed decreased pulmonary perfusion and Tl-201 accumulation of which grade reflects the disease activity in active tuberculous lesion. Patients with miliary tuberculosis and those with silicotuberculosis showed diffuse Tl-201 accumulation in the both lungs. Tl-201 lung scintigraphy seems to be useful for visualizing active tuberculous lesions, particularly the ones that

  16. Contribution of quantitative perfusion pulmonary scintiscanning with particles to the study of the regional pulmonary blood flow distribution

    International Nuclear Information System (INIS)

    Barreto, S.S.M.

    1988-01-01

    The quantitative perfusion pulmonary scintiscanning with macro aggregates was studied by digital images of perfusion, obtained in scintiscanning chamber coupled to the data processing system. The study was developed in four phases, in the Nuclear Medicine Service of Porto Alegre Clinical Hospital. In each phase, it was studied groups with different ages and different clinical aspects (normal and cardiopathic persons), and they were submitted to several diagnostic techniques. The macro aggregates used was the human albumin and was labelled with technetium 99. A comparative evaluation of this method with others diagnostic techniques was also presented. (C.G.C)

  17. Scintigraphic study of blood perfusion of the pulmonary artery in pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Certain, D.A.; Brolio, R.; Salomon, G.C.; Carvalho, N.; Barbosa, Z.L.M.

    1972-01-01

    Blood perfusion in the pulmonary artery is studied by pulmonary scintigraphy with macroaggregated albumin 131 I, in 74 cases of pulmonary tuberculosis. Results shown by scintigraphy are compared to those observed in roentgenography and also correlated with the extension and degree of the lesions, and with the presence of associated tuberculosis, considered capable of changing the scintigraphic picture. The reduction of blood flow in the pulmonary artery are observed in cases of infiltrative, fibrotic of caseous lesions, as well as in cases of minor lesions [pt

  18. Scintigraphic study of blood perfusion of the pulmonary artery in pulmonary tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Certain, D A; Brolio, R; Salomon, G C [Sao Paulo Univ. (Brazil). Faculdade de Saude Publica; Carvalho, N [Sao Paulo Univ. (Brazil). Centro de Medicina Nuclear; Barbosa, Z L.M. [Associacao dos Sanatorios Populares de Campos do Jordao, Brazil

    1972-10-01

    Blood perfusion in the pulmonary artery is studied by pulmonary scintigraphy with macroaggregated albumin /sup 131/I, in 74 cases of pulmonary tuberculosis. Results shown by scintigraphy are compared to those observed in roentgenography and also correlated with the extension and degree of the lesions, and with the presence of associated tuberculosis, considered capable of changing the scintigraphic picture. The reduction of blood flow in the pulmonary artery are observed in cases of infiltrative, fibrotic of caseous lesions, as well as in cases of minor lesions.

  19. Value of the ventilation/perfusion scan in acute pulmonary embolism: Results of the prospective investigation of pulmonary embolism diagnosis (PIOPED)

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    To determine the sensitivities and specificities of ventilation/perfusion lung scans for acute pulmonary embolism, a random sample of 933 of 1,493 patients was studied prospectively. Nine hundred thirty-one underwent scintigraphy and 755 underwent pulmonary angiography; 251 (33%) of 755 demonstrated pulmonary embolism. Almost all patients with pulmonary embolism had abnormal scans of high, intermediate, or low probability, but so did most without pulmonary embolism. Of 116 patients with high-probability scans and definitive angiograms, 102 (88%) had pulmonary embolism, but only a minority with pulmonary embolism had high-probability scans. Of 322 with intermediate-probability scans and definitive angiograms, 105 (33%) had pulmonary embolism. Follow-up and angiography together suggest pulmonary embolism occurred among 12% of patients with low-probability scans. Clinical assessment combined with the ventilation/perfusion scan established the diagnosis or exclusion of pulmonary embolism only for a minority of patients--those with clear and concordant clinical and ventilation/perfusion scan findings

  20. Ventilation and perfusion imaging by electrical impedance tomography: a comparison with radionuclide scanning.

    Science.gov (United States)

    Kunst, P W; Vonk Noordegraaf, A; Hoekstra, O S; Postmus, P E; de Vries, P M

    1998-11-01

    Electrical impedance tomography (EIT) is a technique that makes it possible to measure ventilation and pulmonary perfusion in a volume that approximates to a 2D plane. The possibility of using EIT for measuring the left-right division of ventilation and perfusion was compared with that of radionuclide imaging. Following routine ventilation (81mKr) and perfusion scanning (99mTc-MAA), EIT measurements were performed at the third and the sixth intercostal level in 14 patients with lung cancer. A correlation (r = 0.98, p RC) was calculated for estimating the left-right division with EIT. The RC for the ventilation measurements was 94% and 96% for the perfusion measurements. The correlation analysis for reproducibility of the EIT measurements was 0.95 (p < 0.001) for the ventilation and 0.93 (p < 0.001) for the perfusion measurements. In conclusion, EIT can be regarded as a promising technique to estimate the left-right division of pulmonary perfusion and ventilation.

  1. Role of radio-aerosol and perfusion lung imaging in early detection of chronic obstructive lung disease

    Energy Technology Data Exchange (ETDEWEB)

    Garg, A; Pande, J N; Guleria, J S; Gopinath, P G

    1983-04-01

    The efficacy of radio-aerosol and perfusion lung imaging in the early detection of chronic obstructive lung disease was evaluated in 38 subjects. The subjects included 5 non-smokers, 21 smokers with minimal or no respiratory symptoms and 12 patients with chronic obstructive lung disease. Each subject consented to a respiratory questionaire, detailed physical examination, chest X-ray examinations, detailed pulmonary function tests and sup(99m)Tc-radioaerosol-inhalation lung imaging. Perfusion lung imaging with sup(99m)Tc-labelled macroaggregated albumin was performed in 22 subjects. A significant correlation (P<0.001) was observed between the degree of abnormalities on radio-aerosol imaging and pulmonary function tests (PFTs) including forced expiratory volume in 1 s, maximum midexpiratory flow rate and mean transit time analysis. Abnormal radio-aerosol patterns and deranged PFTs were observed in 21 subjects each. Of 21 subjects with abnormal radioaerosol pattern 8 had normal PFTs. Of 21 subjects with abnormal PFTs 8 had normal aerosol images. Aerosol lung images and PFTs were abnormal more frequently than perfusion lung images. The results suggest that radio-aerosol lung imaging is as sensitive an indicator as PFTs for early detection of chronic obstructive lung disease and can be usefully combined with PFTs for early detection of alteration in pulmonary physiology in smokers.

  2. Perfusion lung scintigraphy in primary pulmonary hypertension

    International Nuclear Information System (INIS)

    Ogawa, Y.; Hayashida, K.; Uehara, T.; Shimonagata, T.; Nishimura, T.; Osaka Univ., Suita

    1993-01-01

    15 cases of primary pulmonary hypertension were classified into two groups by patterns of perfusion lung scintigraphy. Perfusion scintigrams showed multiple, small, ill-defined defects (mottled + ve) pattern in eight cases, and the remaining seven cases had a normal (mottled - ve) pattern. The mean pulmonary arterial pressure in patients with a mottled pattern (54 ± 10 mmHg) was higher than in those with a normal pattern (42 ± 9 mmHg, p < 0.05). There were no significant differences between the two groups in right ventricular ejection fraction, partial pressures of oxygen in the arterial blood or alveolo-arterial oxygen difference. All the patients with a mottled pattern died within 2 years following the lung scintigraphy. There was a significant difference in the survival curves between the two groups. (author)

  3. Evaluation of pulmonary emphysema by the fused image of CT image and ventilation SPECT image

    International Nuclear Information System (INIS)

    Okuda, Ituko; Maruno, Hiromasa; Mori, Kazuaki; Kohno, Tadashi; Kokubo, Takashi

    2007-01-01

    We evaluated pulmonary emphysema using a diagnostic device that could obtain a CT image, a ventilation single photon emission computed tomography (SPECT) image and a lung perfusion SPECT image in one examination. The fused image made from the CT image and SPECT image had very little position gap between images, and the precision was high. From the fused image, we were able to detect the areas in which emphysematous change was the most marked in the CT image, while the accumulation decrease was most remarkable in the ventilation SPECT image. Thus it was possible to obtain an accurate status of pulmonary emphysema, and our method was regarded as a useful technique. (author)

  4. 99mTc-DTPA aerosol for same-day post-perfusion ventilation imaging: Results of a multicentre study

    International Nuclear Information System (INIS)

    Koehn, H.; Koenig, B.; Bachmayr, S.; Markt, B.; Eber, O.; Lind, P.; Galvan, G.; Rettenbacher, L.; Holm, C.; Ogris, E.

    1993-01-01

    A multicentre study was performed in an attempt to evaluate a submicronic technetium-99m diethylene triamine penta-acetic acid aerosol generated by a newly developed delivery system, the aerosol production equipment (APE nebulizer), for same-day post-perfusion ventilation imaging in patients with clinically suspected pulmonary embolism. Quantitative comparison between the DTPA aerosol and krypton gas demonstrated a close correlation with respect to regional pulmonary distribution of activity and peripheral lung penetration (n=14, r=0.94, P 99m Tc-labelled DTPA aerosol is well suited for fast same-day post-perfusion ventilation imaging in patients with clinical suspicion of pulmonary embolism. (orig.)

  5. Software-based hybrid perfusion SPECT/CT provides diagnostic accuracy when other pulmonary embolism imaging is indeterminate

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Nishant; Xie, Karen; Mar, Winnie; Anderson, Thomas M.; Carney, Benjamin; Mehta, Nikhil; Machado, Roberto; Blend, Michael J.; Lu, Yang [University of Illinois Hospital and Health Sciences System, Chicago (Korea, Republic of)

    2015-12-15

    To investigate the diagnostic performance of perfusion single-photon emission computed tomography/computed tomography (Q-SPECT/CT) in patients suspected to have pulmonary embolism (PE) but with indeterminate computed tomographic pulmonary angiography (CTPA) or planar ventilation/perfusion (V/Q) scans. This retrospective study included two groups of patients. Group I consisted of 49 patients with nondiagnostic CTPA. These 49 patients underwent subsequent V/Q scans. Further Q-SPECTs were obtained in patients with indeterminate planar images and fused with existing CTPA. Group II consisted of 182 non-CTPA patients with indeterminate V/Q scans. These 182 patients underwent further Q-SPECT and separate noncontrast low-dose CT chest. Fusion Q-SPECT/CT scans were obtained through FDA-approved software and interpreted according to published criteria as positive, negative, or indeterminate for PE. Upon retrospective analyses, the final diagnosis was made using composite reference standards including all available clinical and imaging information for at least 6-month follow-up. In group I patients, 1 was positive, 24 were negative, and another 24 (49 %, 24/49) were indeterminate. In the subsequent 24 Q-SPECT/CTPAs, 4 were positive, 19 were negative, and 1 was indeterminate (4.2 %, 1/24). In group II patients, 9 (4.9 %, 9/182) were indeterminate, 33 were positive, and 140 were negative. The combined nondiagnostic rate for Q-SPECT/CT was only 4.9 % (10/206). There was six false-negative and one false-positive Q-SPECT/CT examinations. The sensitivity, specificity, and positive and negative predictive value of Q-SPECT/CT were 85.7 % (36/42), 99.4 % (153/154), 97.3 % (36/37) and 96.2 % (153/159), respectively. Q-SPECT/CT improves the diagnostic rate with promising accuracy in diagnosing PE that yields a satisfactory clinical verdict, especially when the CTPA and planar V/Q scan are indeterminate.

  6. Lung perfusion SPECT in predicting postoperative pulmonary function in lung cancer

    International Nuclear Information System (INIS)

    Hirose, Yoshiaki; Imaeda, Takeyoshi; Doi, Hidetaka; Kokubo, Mitsuharu; Sakai, Satoshi; Hirose, Hajime

    1993-01-01

    The aim of this prospective study is to evaluate the availability of preoperative perfusion SPECT in predicting postoperative pulmonary function following resection. Twenty-three patients with lung cancer who were candidates for lobectomy were investigated preoperatively with spirometry, x-ray computed tomography and 99m Tc-macroaggregated albumin SPECT. Their postoperative pulmonary functions were predicted with these examinations. The forced vital capacity and the forced expiratory volume in one second were selected as parameters for overall pulmonary function. The postoperative pulmonary function was predicted by the following formula: Predicted postoperative value=observed preoperative value x precent perfusion of the lung not to be resected. The patients were reinvestigated with spirometry at 3 months and 6 months after lobectomy, and the values obtained were statistically compared with the predicted values. Close relationships were found between predicted and observed forced vital capacity (r=0.87, p<0.001), and predicted and observed forced expiratory volume in one second (r=0.90, p<0.001). The accurate prediction of pulmonary function after lobectomy could be achieved by means of lung perfusion SPECT. (author)

  7. Pulmonary functional MR imaging for COPD

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu

    2008-01-01

    Chronic obstructive pulmonary disease (COPD) is a slowly progressive disease characterized by airflow limitation, cough, sputum production, and, at later stages, dyspnea. COPD is currently the fourth-leading cause of mortality and the twelfth-leading cause of disability, and by the year 2020 it is expected to be the third-leading cause of death and the fifth-leading cause of disability worldwide. The diagnosis of COPD largely relies on a history of exposure to noxious stimuli and abnormal lung function test results. Since the pathology of COPD varies and the molecular mechanisms are only slightly understood, the diagnosis and stage assessment of COPD have relied on the results of pulmonary function test. In addition, CT and nuclear medicine study are utilized for assessment of regional morphological and functional abnormalities. Recently, pulmonary functional MR imaging is suggested as a new technique for assessment of regional physiopathologic information in various pulmonary diseases including COPD, pulmonary thromboembolism, lung cancer and interstitial lung diseases. This review article covers the brief description of theory and clinical application of contrast-enhanced perfusion MR imaging; hyperpolarized noble gas MR imaging and oxygen-enhanced MR imaging in COPD subjects. We believe that further basic studies as well as clinical applications of this new technique will define the real significance of pulmonary functional MR imaging for the future of pulmonary functional imaging and its usefulness for diagnosis and patients' management in COPD. (author)

  8. High temporal versus high spatial resolution in MR quantitative pulmonary perfusion imaging of two-year old children after congenital diaphragmatic hernia repair

    Energy Technology Data Exchange (ETDEWEB)

    Weidner, M.; Hagelstein, C.; Schoenberg, S.O.; Neff, K.W. [University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Institute of Clinical Radiology and Nuclear Medicine, Mannheim (Germany); Zoellner, F.G.; Schad, L.R. [Heidelberg University, Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Mannheim (Germany); Zahn, K. [University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Department of Pediatric Surgery, Mannheim (Germany); Schaible, T. [University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Department of Pediatrics, Mannheim (Germany)

    2014-10-15

    Congenital diaphragmatic hernia (CDH) leads to lung hypoplasia. Using dynamic contrast-enhanced (DCE) MR imaging, lung perfusion can be quantified. As MR perfusion values depend on temporal resolution, we compared two protocols to investigate whether ipsilateral lung perfusion is impaired after CDH, whether there are protocol-dependent differences, and which protocol is preferred. DCE-MRI was performed in 36 2-year old children after CDH on a 3 T MRI system; protocol A (n = 18) based on a high spatial (3.0 s; voxel: 1.25 mm{sup 3}) and protocol B (n = 18) on a high temporal resolution (1.5 s; voxel: 2 mm{sup 3}). Pulmonary blood flow (PBF), pulmonary blood volume (PBV), mean transit time (MTT), and peak-contrast-to-noise-ratio (PCNR) were quantified. PBF was reduced ipsilaterally, with ipsilateral PBF of 45 ± 26 ml/100 ml/min to contralateral PBF of 63 ± 28 ml/100 ml/min (p = 0.0016) for protocol A; and for protocol B, side differences were equivalent (ipsilateral PBF = 62 ± 24 vs. contralateral PBF = 85 ± 30 ml/100 ml/min; p = 0.0034). PCNR was higher for protocol B (30 ± 18 vs. 20 ± 9; p = 0.0294). Protocol B showed higher values of PBF in comparison to protocol A (p always <0.05). Ipsilateral lung perfusion is reduced in 2-year old children following CDH repair. Higher temporal resolution and increased voxel size show a gain in PCNR and lead to higher perfusion values. Protocol B is therefore preferred. (orig.)

  9. Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Dournes, Gael; Verdier, Damien; Montaudon, Michel; Laurent, Francois; Lederlin, Mathieu [Hopital Haut-Leveque, CHU Bordeaux, Department of Medical Imaging, Pessac (France); University Bordeaux Segalen, Bordeaux Cedex (France); Bullier, Eric; Riviere, Annalisa [Hopital Haut-Leveque, CHU Bordeaux, Department of Nuclear Medicine, Pessac (France); Dromer, Claire [Hopital Haut-Leveque, CHU Bordeaux, Department of Respiratory Diseases, Pessac (France); Picard, Francois [Hopital Haut-Leveque, CHU Bordeaux, Department of Cardiology, Pessac (France); Billes, Marc-Alain [Hopital Haut-Leveque, CHU Bordeaux, Department of Cardiac Surgery, Pessac (France); Corneloup, Olivier [Hopital Haut-Leveque, CHU Bordeaux, Department of Medical Imaging, Pessac (France)

    2014-01-15

    To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) perfusion and angiography versus ventilation/perfusion (V/Q) scintigraphy in chronic thromboembolic pulmonary hypertension (CTEPH), and to assess the per-segment concordance rate of DECT and scintigraphy. Forty consecutive patients with proven pulmonary hypertension underwent V/Q scintigraphy and DECT perfusion and angiography. Each imaging technique was assessed for the location of segmental defects. Diagnosis of CTEPH was established when at least one segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy of DECT perfusion and angiography was assessed and compared with scintigraphy. In CTEPH patients, the per-segment concordance between scintigraphy and DECT perfusion/angiography was calculated. Fourteen patients were diagnosed with CTEPH and 26 with other aetiologies. DECT perfusion and angiography correctly identified all CTEPH patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At a segmental level, DECT perfusion showed moderate agreement (κ = 0.44) with scintigraphy. Agreement between CT angiography and scintigraphy ranged from fair (κ = 0.31) to slight (κ = 0.09) depending on whether completely or partially occlusive patterns were considered, respectively. Both DECT perfusion and angiography show satisfactory performance for the diagnosis of CTEPH. DECT perfusion is more accurate than angiography at identifying the segmental location of abnormalities. (orig.)

  10. Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy

    International Nuclear Information System (INIS)

    Dournes, Gael; Verdier, Damien; Montaudon, Michel; Laurent, Francois; Lederlin, Mathieu; Bullier, Eric; Riviere, Annalisa; Dromer, Claire; Picard, Francois; Billes, Marc-Alain; Corneloup, Olivier

    2014-01-01

    To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) perfusion and angiography versus ventilation/perfusion (V/Q) scintigraphy in chronic thromboembolic pulmonary hypertension (CTEPH), and to assess the per-segment concordance rate of DECT and scintigraphy. Forty consecutive patients with proven pulmonary hypertension underwent V/Q scintigraphy and DECT perfusion and angiography. Each imaging technique was assessed for the location of segmental defects. Diagnosis of CTEPH was established when at least one segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy of DECT perfusion and angiography was assessed and compared with scintigraphy. In CTEPH patients, the per-segment concordance between scintigraphy and DECT perfusion/angiography was calculated. Fourteen patients were diagnosed with CTEPH and 26 with other aetiologies. DECT perfusion and angiography correctly identified all CTEPH patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At a segmental level, DECT perfusion showed moderate agreement (κ = 0.44) with scintigraphy. Agreement between CT angiography and scintigraphy ranged from fair (κ = 0.31) to slight (κ = 0.09) depending on whether completely or partially occlusive patterns were considered, respectively. Both DECT perfusion and angiography show satisfactory performance for the diagnosis of CTEPH. DECT perfusion is more accurate than angiography at identifying the segmental location of abnormalities. (orig.)

  11. Pulmonary imaging using dual-energy CT, a role of the assessment of iodine and air distribution

    Energy Technology Data Exchange (ETDEWEB)

    Ferda, Jiri, E-mail: e-mail@fnplzen.cz [Radiodiagnostic Clinic, Charles University Teaching Hospital Plzen, Alej Svobody 80, 30640 Plzen (Czech Republic); Ferdova, Eva; Mirka, Hynek; Baxa, Jan; Bednarova, Alena [Radiodiagnostic Clinic, Charles University Teaching Hospital Plzen, Alej Svobody 80, 30640 Plzen (Czech Republic); Flohr, Thomas; Schmidt, Bernhard [Siemens Healthcare, Computed Tomography, 91301 Siemensstr. 1, Forchheim (Germany); Matejovic, Martin [1st Internal Department, Charles University Teaching Hospital Plzen, Alej Svobody 80, 30640 Plzen (Czech Republic); Kreuzberg, Boris [Radiodiagnostic Clinic, Charles University Teaching Hospital Plzen, Alej Svobody 80, 30640 Plzen (Czech Republic)

    2011-02-15

    Aim: The aim of the study is to present the feasibility of using dual-energy CT and the evaluation of iodine and air distribution in differentiation of pathological conditions. Material and method: We used the data of 50 CT examinations performed due to suspected pulmonary embolism with any pathological finding except consolidation of the parenchyma. The patients underwent CT angiography of the pulmonary arteries on a dual-source CT (DSCT), with the two tubes independently operated at 140 and 80 kV. By exploiting the dual-energy information, iodine distribution maps were obtained in addition to the conventional CT images which served as a marker of pulmonary perfusion. Minimum intensity projections (MinIP) were used as a marker of air content. Results: By comparing the iodine distribution maps and MinIP images, it was possible to differentiate between the following templates of lung parenchyma: A - normal iodine and air distribution; B - iodine content deficit with minimal or with no redistribution of air; C - reduced iodine content and increased content of air; D - deficit of iodine content and increased content of air; E - increased iodine content and normal content of air; F - increased iodine content and reduced content of air; G - reduced perfusion and reduced content of air. The type A (five cases) was typical for the pulmonary embolism with preserved normal conditions of perfusion and ventilation. Type B (18 cases) occurred in pulmonary embolism; type C was found in case of inflammation of small respiratory airways (five cases); emphysema was typical for type D (nine cases); increased perfusion was observed in the parenchyma preserved from emphysema or preserved from embolism in cases of emphysema or pulmonary embolism; type F occurred in pulmonary interstitial edema (four cases) both with pulmonary infection; finally type G was found in interstitial lung diseases (five cases). Conclusion: Imaging of the pulmonary circulation by means of dual-energy CT opens

  12. Improved visualization of delayed perfusion in lung MRI

    International Nuclear Information System (INIS)

    Risse, Frank; Eichinger, Monika; Kauczor, Hans-Ulrich; Semmler, Wolfhard; Puderbach, Michael

    2011-01-01

    Introduction: The investigation of pulmonary perfusion by three-dimensional (3D) dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) was proposed recently. Subtraction images are generated for clinical evaluation, but temporal information is lost and perfusion defects might therefore be masked in this process. The aim of this study is to demonstrate a simple analysis strategy and classification for 3D-DCE-MRI perfusion datasets in the lung without omitting the temporal information. Materials and methods: Pulmonary perfusion measurements were performed in patients with different lung diseases using a 1.5 T MR-scanner with a time-resolved 3D-GRE pulse sequence. 25 3D-volumes were acquired after iv-injection of 0.1 mmol/kg KG Gadolinium-DTPA. Three parameters were determined for each pixel: (1) peak enhancement S n,max normalized to the arterial input function to detect regions of reduced perfusion; (2) time between arterial peak enhancement in the large pulmonary artery and tissue peak enhancement τ to visualize regions with delayed bolus onset; and (3) ratio R = S n,max /τ was calculated to visualize impaired perfusion, irrespectively of whether related to reduced or delayed perfusion. Results: A manual selection of peak perfusion images is not required. Five different types of perfusion can be found: (1) normal perfusion; (2) delayed non-reduced perfusion; (3) reduced non-delayed perfusion; (4) reduced and delayed perfusion; and (5) no perfusion. Types II and IV could not be seen in subtraction images since the temporal information is necessary for this purpose. Conclusions: The analysis strategy in this study allows for a simple and observer-independent visualization and classification of impaired perfusion in dynamic contrast-enhanced pulmonary perfusion MRI by using the temporal information of the datasets.

  13. Quantitative pulmonary perfusion imaging with 3-dimensional, contrast-enhanced MR: regional difference in the perfusion parameters of healthy volunteers

    International Nuclear Information System (INIS)

    Kim, Song Soo; Seo, Joon Beom; Kim, Nam Kuk; Do, Kyung Hyun; Lee, Young Kyung; Song, Jae Woo; Lee, Jin Seong; Kim, Jin Hwan

    2007-01-01

    We wanted to evaluate the regional differences in such perfusion parameters as pulmonary blood flow (PBF), mean transit time (MTT) and pulmonary blood volume (PBV) in the entire lung of healthy volunteers with using three-dimensional, contrast-enhanced MR imaging (3D CEMRI). Six healthy volunteers underwent dynamic 3D CEMRI (TR/TE 2.7/0.6 msec; flip angle 40 .deg. ; matrix 128 x 96; reconstructed matrix 256 x 192; rectangular field of view 450 x 315 mm; coronal 100-150mm-thick x 10 slabs; temporal resolution 1.0 sec; 35 dynamic phases) For all subjects, 2 mL of Gd-DTPA mixed with 3 ml of physiologic saline was administered as a bolus at a rate of 5 mL/sec, and this was followed by 20 mL of physiologic saline flush. From the signal intensity-time curves, the PBF, MTT and PBV maps were generated using indicator dilution theories and the central volume principle on a pixel-by-pixel basis. A total of 54 round, 1-cm sized ROIs were placed in the lung in each subject (6 ROIs per slab x 9 slices except for the most posterior slab). The regional differences of the measured parameters were statistically evaluated in the gravitational direction and in the upper-mid-lower direction by one-way ANOVA tests. The calculated PBF, MTT and PBV in the entire lung were 141.8 ± 53.4 mL/100 mL/min (mean ± SD), 5.35 ± 1.38 sec, and 13.4 ± 6.48 mL/100mL, respectively. In the gravitational direction, there was a significant increase in the PBF and PBV as it goes to the posterior direction (ρ < 0.05). No statistical difference was found in PBF or PBV between the upper, mid and lower lung zone areas. Regional difference in the various perfusion parameters of the lung in healthy volunteers can be quantitatively assessed with performing 3D CEMRI

  14. Assessment of pulmonary ventilation/perfusion ratio by dual radionuclides SPECT using 81mKr gas and 99mTc-MAA

    International Nuclear Information System (INIS)

    Sando, Yoshichika

    1994-01-01

    The accuracy and clinical availability of pulmonary ventilation/perfusion (V/Q) ratio images by 81m Kr gas and 99m Tc-MAA dual radionuclides SPECT was assessed in 10 normal volunteers and 31 patients with pulmonary diseases. After equalizing the total acquisition counts of both radionuclides, the ratio of 81m Kr/ 99m Tc count was calculated in each pixel and expressed as the functional map of V/Q. Then, the histogram of pixel numbers against V/Q ratio was drawn and the center of weight (CW) and standard deviation (SD) of the distribution were determined. The reproducibility of this method was excellent. In normal volunteers, CW was 1.07 and the SD was 0.25. The V/Q was lower in dorsal than in the ventral portion. SD was large and lobar or segmental high V/Q areas were clearly noted in the patients with pulmonary vascular diseases. In pulmonary emphysema, large low V/Q areas coexisted with patchy high V/Q areas. CW was small and SD was large in this group. There was a significant positive correlation between SD and P A-a O 2 . The author believes that the pulmonary ventilation/perfusion (V/Q) ratio images by dual radionuclides SPECT is a useful diagnostic procedure. Further, SD determined by this examination is thought to be a good parameter of uneven distribution of pulmonary ventilation and perfusion. (author)

  15. High-resolution imaging of pulmonary ventilation and perfusion with {sup 68}Ga-VQ respiratory gated (4-D) PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Callahan, Jason [Centre for Molecular Imaging, Peter MacCallum Cancer Centre, East Melbourne, VIC (Australia); Hofman, Michael S. [The University of Melbourne, Department of Medicine, Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne, VIC (Australia); Siva, Shankar [The University of Melbourne, Peter MacCallum Cancer Centre, Department of Radiation Oncology, East Melbourne, VIC (Australia); The University of Melbourne, Sir Peter MacCallum Department of Oncology, East Melbourne, VIC (Australia); Kron, Tomas [The University of Melbourne, Sir Peter MacCallum Department of Oncology, East Melbourne, VIC (Australia); The University of Melbourne, Peter MacCallum Cancer Centre, Department of Physical Sciences, East Melbourne, VIC (Australia); Schneider, Michal E. [Monash University, Department of Medical Imaging and Radiation Science, Clayton, VIC (Australia); Binns, David; Eu, Peter [Peter MacCallum Cancer Centre, Centre for Cancer Imaging, East Melbourne, VIC (Australia); Hicks, Rodney J. [The University of Melbourne, Sir Peter MacCallum Department of Oncology, Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne, VIC (Australia)

    2014-02-15

    Our group has previously reported on the use of {sup 68}Ga-ventilation/perfusion (VQ) PET/CT scanning for the diagnosis of pulmonary embolism. We describe here the acquisition methodology for {sup 68}Ga-VQ respiratory gated (4-D) PET/CT and the effects of respiratory motion on image coregistration in VQ scanning. A prospective study was performed in 15 patients with non-small-cell lung cancer. 4-D PET and 4-D CT images were acquired using an infrared marker on the patient's abdomen as a surrogate for breathing motion following inhalation of Galligas and intravenous administration of {sup 68}Ga-macroaggregated albumin. Images were reconstructed with phase-matched attenuation correction. The lungs were contoured on CT and PET VQ images during free-breathing (FB) and at maximum inspiration (Insp) and expiration (Exp). The similarity between PET and CT volumes was measured using the Dice coefficient (DC) comparing the following groups; (1) FB-PET/CT, (2) InspPET/InspCT, (3) ExpPET/Exp CT, and (4) FB-PET/AveCT. A repeated measures one-way ANOVA with multiple comparison Tukey tests were performed to evaluate any difference between the groups. Diaphragmatic motion in the superior-inferior direction on the 4-D CT scan was also measured. 4-D VQ scanning was successful in all patients without additional acquisition time compared to the nongated technique. The highest volume overlap was between ExpPET and ExpCT and between FB-PET and AveCT with a DC of 0.82 and 0.80 for ventilation and perfusion, respectively. This was significantly better than the DC comparing the other groups (0.78-0.79, p < 0.05). These values agreed with a visual inspection of the images with improved image coregistration around the lung bases. The diaphragmatic motion during the 4-D CT scan was highly variable with a range of 0.4-3.4 cm (SD 0.81 cm) in the right lung and 0-2.8 cm (SD 0.83 cm) in the left lung. Right-sided diaphragmatic nerve palsy was observed in 3 of 15 patients. {sup 68}Ga-VQ 4-D

  16. Normal anatomy of lung perfusion SPECT scintigraphy

    International Nuclear Information System (INIS)

    Moskowitz, G.W.; Levy, L.M.

    1987-01-01

    Ten patients studies for possible pulmonary embolic disease had normal lung perfusion planar and SPECT scintigraphy. A computer program was developed to superimpose the CT scans on corresponding SPECT images. Superimposition of CT scans on corresponding SPECT transaxial cross-sectional images, when available, provides the needed definition and relationships of adjacent organs. SPECT transaxial sections provide clear anatomic definition of perfusion defects without foreground and background lung tissue superimposed. The location, shape, and size of the perfusion defects can be readily assessed by SPECT. An algorithm was developed for the differentiation of abnormal pulmonary perfusion patterns from normal structures on variation

  17. Pulmonary ventilation/perfusion single photon emission tomography – Initial experience of a Nuclear Medicine Department

    Directory of Open Access Journals (Sweden)

    J. G. Santos

    2016-01-01

    Full Text Available Introduction: Lung ventilation/perfusion scintigraphy with planar images (V/QS-planar is very useful for the diagnosis and follow-up of pulmonary thromboembolism (PTE. Acquiring tomographic images (V/QS-SPECT is a recent development with potential to increase the technique's accuracy. The purpose of this work is to evaluate the added benefits of V/QS-SPECT studies as opposed to traditional planar imaging. Patients and methods: We prospectively revised 53 V/QS-planar and V/QS-SPECT exams, performed according to the European Association of Nuclear Medicine guidelines. We evaluated the exams independently, by consensus of two Nuclear Medicine physicians. For both methods, we gave each lung a score expressing the dimension and extension of perfusion defects with normal ventilation. For each lung, we compared the scores with the paired Wilcoxon test, estimating the 95% confidence interval (95CI for the respective difference. Results: We performed V/QS-SPECT exams without technical difficulties. The paired Wilcoxon test estimated the score difference to be −0.75 (95CI of −1.0 to −0.5; p-value = 9.6 × 10−7, expressing a statistically significant difference of about 1 subsegmental defect between both methods, with V/QS-SPECT detecting more defects. Discussion: The results demonstrate that V/QS-SPECT identifies a slightly larger number of perfusion defects than V/QS-planar, suggesting a higher sensitivity of this technique. However, more studies are necessary to evaluate the clinical meaning of this fact. Conclusion: V/QS-SPECT demonstrates a higher capability to identify perfusion defects. This method looks promising, allowing for a greater role of this exam in pulmonary thromboembolism diagnosis and follow-up. Keywords: Pulmonary thromboembolism, Lung, Scintigraphy, Single-photon emission-computed tomography (SPECT

  18. Correlation of 68Ga Ventilation-Perfusion PET/CT with Pulmonary Function Test Indices for Assessing Lung Function.

    Science.gov (United States)

    Le Roux, Pierre-Yves; Siva, Shankar; Steinfort, Daniel P; Callahan, Jason; Eu, Peter; Irving, Lou B; Hicks, Rodney J; Hofman, Michael S

    2015-11-01

    Pulmonary function tests (PFTs) are routinely used to assess lung function, but they do not provide information about regional pulmonary dysfunction. We aimed to assess correlation of quantitative ventilation-perfusion (V/Q) PET/CT with PFT indices. Thirty patients underwent V/Q PET/CT and PFT. Respiration-gated images were acquired after inhalation of (68)Ga-carbon nanoparticles and administration of (68)Ga-macroaggregated albumin. Functional volumes were calculated by dividing the volume of normal ventilated and perfused (%NVQ), unmatched and matched defects by the total lung volume. These functional volumes were correlated with forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), FEV1/FVC, and diffusing capacity for carbon monoxide (DLCO). All functional volumes were significantly different in patients with chronic obstructive pulmonary disease (P volume of unmatched defects (r = -0.55). Considering %NVQ only, a cutoff value of 90% correctly categorized 28 of 30 patients with or without significant pulmonary function impairment. Our study demonstrates strong correlations between V/Q PET/CT functional volumes and PFT parameters. Because V/Q PET/CT is able to assess regional lung function, these data support the feasibility of its use in radiation therapy and preoperative planning and assessing pulmonary dysfunction in a variety of respiratory diseases. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  19. Chronic pulmonary embolism - radiological imaging and differential diagnosis; Chronische Lungenembolie - Radiologische Bildmorphologie und Differenzialdiagnose

    Energy Technology Data Exchange (ETDEWEB)

    Coppenrath, E.; Herzog, P.; Attenberger, U.; Reiser, M. [Klinikum Innenstadt der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2007-08-15

    In chronic pulmonary embolism branches of the pulmonary arterial tree remain partially or totally occluded. This may lead to pulmonary hypertension with the development of right ventricular hypertrophy as well as structural changes of pulmonary arteries. Imaging of chronic pulmonary embolism should prove vessel occlusions (pulmonary angiography, MSCT, MRI) and reduction of regional lung perfusion (lung scanning, MSCT, MRI). According to current guidelines ventilation-perfusion lung scanning and pulmonary angiography are still recommended as the methods of choice. MSCT and MRI provide technical alternatives which are helpful in differential diagnosis versus other types of pulmonary hypertension. In spite of medical and surgical measures (in rare cases pulmonary thromboendarterectomy) the prognosis of chronic pulmonary embolism remains unfavourable. (orig.) [German] Bei der chronischen Lungenembolie sind Abschnitte der arteriellen Lungenstrombahn dauerhaft verschlossen. Dies kann zu einer Erhoehung des pulmonal-arteriellen Drucks mit den Folgen einer Rechtsherzbelastung und strukturellen Veraenderungen der Pulmonalarterien fuehren. Bildmorphologisch nachzuweisen sind Gefaessverschluesse (Pulmonalisangiographie, MSCT, MRT) und die Minderperfusion des Lungenparenchyms (Szintigraphie, MSCT, MRT). Nach den bisherigen Empfehlungen gelten fuer die Diagnostik der chronischen Lungenembolie die Lungenszintigraphie (Ventilation/Perfusion) und die Pulmonalisangiographie als Methoden der ersten Wahl. Die MSCT und MRT (Angiographie/Perfusion) stellen technische Alternativen dar. Differenzialdiagnostisch sind andere Formen der pulmonalen Hypertonie abzugrenzen. Trotz medikamentoeser und chirurgischer Therapiemassnahmen (z. B. pulmonale Thrombendarterektomie) bleibt die Prognose der chronischen Lungenembolie unguenstig. (orig.)

  20. Prediction of postoperative pulmonary function using 99mTc-MAA perfusion lung SPECT

    International Nuclear Information System (INIS)

    Hosokawa, Nobuyuki; Tanabe, Masatada; Satoh, Katashi; Takashima, Hitoshi; Ohkawa, Motoomi; Maeda, Masazumi; Tamai, Toyosato; Kojima, Kanji.

    1995-01-01

    In order to predict postoperative pulmonary function, 99m Tc-MAA perfusion lung SPECT and spirometry were performed preoperatively in 52 patients with resectable primary lung cancer; 44 underwent lobectomy, eight pneumonectomy. Local pulmonary function (called local effective volume) was evaluated according to the degree of radionuclide distribution of each voxel in the SPECT images. The total effective volume was defined as the sum of the local effective volume, and the residual effective volume was the total effective volume excluding loss after operation. Predicted pulmonary function (VC and FEV 1.0) was calculated by the following formula: Predicted value=preoperative value x percent of the residual effective volume. Postoperative pulmonary function was predicted in the same patients by means of 99m Tc-MAA perfusion lung planar scintigraphy and X-ray CT. The patients were reinvestigated with spirometry at one and four months after surgery, and the values were compared with the predicted values. The correlations between the predicted values using SPECT and measured postoperative pulmonary function were highly significant (VC: r=0.867, FEV1.0: r=0.864 one month after operation; VC: r=0.860, FEV1.0: r=0.907 4 months after operation). The predicted values calculated using SPECT were accurate compared with the predicted values calculated using planar scintigraphy or X-ray CT. The patients with predicted FEV1.0 of less than 0.8 liter required home oxygen therapy. This method is valuable for the prediction of postoperative pulmonary function before the surgical procedure. (author)

  1. Imaging features of isolated unilateral pulmonary artery agenesis presenting in adulthood: a review of four cases

    International Nuclear Information System (INIS)

    Griffin, N.; Mansfield, L.; Redmond, K.C.; Dusmet, M.; Goldstraw, P.; Mittal, T.K.; Padley, S.

    2007-01-01

    Aim: To highlight the variation in clinical manifestations, imaging and management of four cases of unilateral pulmonary artery agenesis presenting in adulthood. Method: Four patients with unilateral pulmonary artery agenesis were referred to our institution between 1995 and 2005. They underwent a series of investigations, including chest radiography, echocardiography, ventilation perfusion scintigraphy, angiography, computed tomography (CT) and magnetic resonance imaging (MRI). Results: Two of the four patients had absence of the right main pulmonary artery, whilst the remaining two patients had absence of the left main pulmonary artery. One patient showed a restrictive defect on pulmonary function tests. Two patients who had ventilation perfusion scintigraphy showed absent perfusion and reduced ventilation on the affected side. Angiography (where performed), CT and MRI confirmed the anatomy and the presence of multiple collaterals. Bronchiectasis was demonstrated on CT in two patients, with one also demonstrating a mosaic attenuation pattern. One patient had an incidental lung tumour on the side of the agenesis, which was diagnosed as a chondroid hamartoma on histology. Three of the four patients eventually underwent resection of the affected lung. Conclusion: Isolated unilateral pulmonary artery agenesis has a non-specific presentation. Awareness of this condition can lead to earlier diagnosis, with cross-sectional imaging making an important contribution

  2. Imaging features of isolated unilateral pulmonary artery agenesis presenting in adulthood: a review of four cases

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, N. [Royal Brompton and Harefield NHS Trust, London (United Kingdom)]. E-mail: nyreegriffin@hotmail.com; Mansfield, L. [Royal Brompton and Harefield NHS Trust, London (United Kingdom); Redmond, K.C. [Royal Brompton and Harefield NHS Trust, London (United Kingdom); Dusmet, M. [Royal Brompton and Harefield NHS Trust, London (United Kingdom); Goldstraw, P. [Royal Brompton and Harefield NHS Trust, London (United Kingdom); Mittal, T.K. [Royal Brompton and Harefield NHS Trust, London (United Kingdom); Padley, S. [Royal Brompton and Harefield NHS Trust, London (United Kingdom)

    2007-03-15

    Aim: To highlight the variation in clinical manifestations, imaging and management of four cases of unilateral pulmonary artery agenesis presenting in adulthood. Method: Four patients with unilateral pulmonary artery agenesis were referred to our institution between 1995 and 2005. They underwent a series of investigations, including chest radiography, echocardiography, ventilation perfusion scintigraphy, angiography, computed tomography (CT) and magnetic resonance imaging (MRI). Results: Two of the four patients had absence of the right main pulmonary artery, whilst the remaining two patients had absence of the left main pulmonary artery. One patient showed a restrictive defect on pulmonary function tests. Two patients who had ventilation perfusion scintigraphy showed absent perfusion and reduced ventilation on the affected side. Angiography (where performed), CT and MRI confirmed the anatomy and the presence of multiple collaterals. Bronchiectasis was demonstrated on CT in two patients, with one also demonstrating a mosaic attenuation pattern. One patient had an incidental lung tumour on the side of the agenesis, which was diagnosed as a chondroid hamartoma on histology. Three of the four patients eventually underwent resection of the affected lung. Conclusion: Isolated unilateral pulmonary artery agenesis has a non-specific presentation. Awareness of this condition can lead to earlier diagnosis, with cross-sectional imaging making an important contribution.

  3. Comparison of ventilation-perfusion single-photon emission computed tomography (V/Q SPECT) versus dual-energy CT perfusion and angiography (DECT) after 6 months of pulmonary embolism (PE) treatment

    Energy Technology Data Exchange (ETDEWEB)

    Meysman, M., E-mail: marc.meysman@uzbrussel.be [Respiratory Division, Department of Medicine, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Brussels (Belgium); Everaert, H., E-mail: nucgeth@gmail.com [Department of Nuclear Medicine, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Brussels (Belgium); Buls, N., E-mail: nico.buls@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Brussels (Belgium); Nieboer, K., E-mail: koenraad.nieboer@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Brussels (Belgium); Mey, J. de, E-mail: Johan.deMey@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Brussels (Belgium)

    2015-09-15

    Highlights: • Incomplete resolution of pulmonary emboli occurs frequently. • Residual V/Q-SPECT defects correspond in the majority of cases with defects seen on DECT. • Some (11.1%) defects on V/Q-SPECT are not present on comparable DECT images. - Abstract: Background: The natural evolution of treated symptomatic pulmonary embolism shows often incomplete resolution of pulmonary thrombi. The prevalence of perfusion defects depend on the image modality used. This study directly compares V/Q SPECT with DECT. Methods: A single-center prospective observational cohort study of patients with intermediate risk PE, reassessed at the end of treatment with V/Q SPECT. Abnormal V/Q SPECT images were compared with DECT. Results: We compared DECT en V/Q SPECT in 28 consecutive patients with persistent V/Q mismatch on V/Q SPECT, 13 men and 15 woman, mean age 60 (+17), range 23–82 year. One patient was excluded from the final analysis due to inferior quality DECT. In 18/27 (66.7%) the results were concordant between CTPA (persistent embolus visible), DECT (segmentary defects on iodine map) and V/Q SPECT (segmentary ventilation–perfusion mismatch). In 3/18 (11.1% of the total group) the partialy matched V/Q SPECT defect could be explained on DECT lung images by lung infarction. In 6/27 (22.1%) only hypoperfusion was seen on DECT iodine map. In 3/27 (11.1%) results were discordant between V/Q SPECT and DECT images. Conclusion: Six months after diagnosis of first or recurrent PE, residual pulmonary perfusion-defects encountered on V/Q-SPECT corresponds in the majority of patients with chronic thromboembolic disease seen on DECT. In 22.1% of patients V/Q SPECT mismatch only corresponds with hypoperfusion on iodine map DECT scan. Some (11.1%) of the chronic thromboembolic lesions seen on V/Q SPECT can not be explained by DECT results.

  4. Effects of smoking on lung uptake of 201Tl during exercise myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Ouyang Wei; He Guorong; Liu Jinhua

    2004-01-01

    Objective: To investigate the influence of smoking on lung uptake of 201 Tl during myocardial perfusion imaging. Methods: Ninety-two healthy subjects, with normal 201 Tl myocardial perfusion imaging findings but no evidence of left ventricular hypertrophy and pulmonary disease, were divided into three groups, smoker, nonsmoker and quitted smoker groups. Exercise/delay 201 Tl myocardial perfusion imaging was performed on all subjects included. Lung/heart ratio was defined on the anterior planar image obtained during exercise tomography. Results: Both the lung/heart ratios during exercise in smoker (0.40 ± 0.07, F=10.635, P 201 Tl lung/heart ratios in smokers are higher than in nonsmokers and this must be kept in mind when 201 Tl lung/heart ratios are used clinically, even in quitted smokers

  5. Evaluation of postoperative follow-up of children's congenital heart disease with pulmonary hypertension by pulmonary imaging

    International Nuclear Information System (INIS)

    Zheng Jinghao; Zhang Shantong; Zeng Jihua

    1994-01-01

    Pulmonary perfusion imaging with 99m Tc labelled macroaggregated albumin (MAA) was performed in 48 cases of congenital heart diseases of children, including 32 cases with pulmonary hypertension (PH). The change in the total count ratio of the right lung against the left lung between right and left lateral decubitus positions (rt/lt) was used to assess the pulmonary arterial pressure postoperatively. The results showed that rt/lt ratio could qualitatively evaluate the pulmonary arterial pressure. The reproducibility of rt/lt ratio was quite good in experiments with rabbits. Some factors which affected the recovery of PH after operation have been discussed

  6. Estimation of pulmonary hypertension of congenital heart diseases in children by lung perfusion scintigraphy

    International Nuclear Information System (INIS)

    Zheng Jinghao; Zhang Shantong; Zeng Jiye; Jia Hongli; Ji Zhiying; Chen Siyi

    1993-01-01

    The authors report that changes in the distribution of pulmonary perfusion caused by gravitation effect, namely, changes in the total count ratios of the right against the left lung between right and left lateral decubitus positions (rt/lt) could estimate pulmonary hypertension using lung perfusion scintigraphy with 99m Tc-labelled macroaggregated albumin. The results showed: rt/lt was inversely related to mean pulmonary arterial pressure. It is concluded that the method is simple, safe, reproducible, unaffected by cardiac structural abnormality and valuable as a noninvasive approach for the estimation of pulmonary hypertension

  7. Laser doppler perfusion imaging

    International Nuclear Information System (INIS)

    Waardell, K.

    1992-01-01

    Recording of tissue perfusion is important in assessing the influence of peripheral vascular diseases on the microcirculation. This thesis reports on a laser doppler perfusion imager based on dynamic light scattering in tissue. When a low power He-Ne laser beam sequentally scans the tissue, moving blood cells generate doppler components in the back-scattered light. A fraction of this light is detected by a photodetector and converted into an electrical signal. In the processor, a signal proportional to the tissue perfusion at each measurement site is calculated and stored. When the scanning procedure is completed, a color-coded perfusion image is presented on a monitor. To convert important aspects of the perfusion image into more quantitative parameters, data analysis functions are implemented in the software. A theory describing the dependence of the distance between individual measurement points and detector on the system amplification factor is proposed and correction algorithms are presented. The performance of the laser doppler perfusion imager was evaluated using a flow simulator. A linear relationship between processor output signal and flow through the simulator was demonstrated for blood cell concentrations below 0.2%. The median sampling depth of the laser beam was simulated by a Monte Carlo technique and estimated to 235 μm. The perfusion imager has been used in the clinic to study perfusion changes in port wine stains treated with argon laser and to investigate the intensity and extension of the cutaneous axon reflex response after electrical nerve stimulation. The fact that perfusion can be visualized without touching the tissue implies elimination of sterilization problems, thus simplifying clinical investigations of perfusion in association with diagnosis and treatment of peripheral vascular diseases. 22 refs

  8. Assessment of pulmonary hypertension by CT and MR imaging

    International Nuclear Information System (INIS)

    Ley, Sebastian; Kreitner, Karl-Friedrich; Heussel, Claus P.; Fink, Christian; Kauczor, Hans-Ulrich; Borst, Mathias M.

    2004-01-01

    In the recent World Health Organization (WHO) classification the group of pulmonary arterial hypertension (PH) comprises the classic primary pulmonary hypertension and several conditions with definite or very high risk factors to develop pulmonary arterial hypertension. Therapeutic advances drive the need for a comprehensive pre-therapeutic evaluation for optimal treatment. Furthermore, follow-up examinations need to be performed to monitor changes in disease status and response to therapy. Up to now, the diagnostic imaging work-up of PH comprises mainly echocardiography, invasive right heart catheterization and ventilation/perfusion scintigraphy. Due to technical advances helical computed tomography (CT) and magnetic resonance imaging (MRI) became more important in the evaluation and for differential diagnosis of pulmonary arterial hypertension. Both modalities are reviewed and recommendations for clinical use are given. (orig.)

  9. Time-resolved 3D pulmonary perfusion MRI: comparison of different k-space acquisition strategies at 1.5 and 3 T.

    Science.gov (United States)

    Attenberger, Ulrike I; Ingrisch, Michael; Dietrich, Olaf; Herrmann, Karin; Nikolaou, Konstantin; Reiser, Maximilian F; Schönberg, Stefan O; Fink, Christian

    2009-09-01

    Time-resolved pulmonary perfusion MRI requires both high temporal and spatial resolution, which can be achieved by using several nonconventional k-space acquisition techniques. The aim of this study is to compare the image quality of time-resolved 3D pulmonary perfusion MRI with different k-space acquisition techniques in healthy volunteers at 1.5 and 3 T. Ten healthy volunteers underwent contrast-enhanced time-resolved 3D pulmonary MRI on 1.5 and 3 T using the following k-space acquisition techniques: (a) generalized autocalibrating partial parallel acquisition (GRAPPA) with an internal acquisition of reference lines (IRS), (b) GRAPPA with a single "external" acquisition of reference lines (ERS) before the measurement, and (c) a combination of GRAPPA with an internal acquisition of reference lines and view sharing (VS). The spatial resolution was kept constant at both field strengths to exclusively evaluate the influences of the temporal resolution achieved with the different k-space sampling techniques on image quality. The temporal resolutions were 2.11 seconds IRS, 1.31 seconds ERS, and 1.07 VS at 1.5 T and 2.04 seconds IRS, 1.30 seconds ERS, and 1.19 seconds VS at 3 T.Image quality was rated by 2 independent radiologists with regard to signal intensity, perfusion homogeneity, artifacts (eg, wrap around, noise), and visualization of pulmonary vessels using a 3 point scale (1 = nondiagnostic, 2 = moderate, 3 = good). Furthermore, the signal-to-noise ratio in the lungs was assessed. At 1.5 T the lowest image quality (sum score: 154) was observed for the ERS technique and the highest quality for the VS technique (sum score: 201). In contrast, at 3 T images acquired with VS were hampered by strong artifacts and image quality was rated significantly inferior (sum score: 137) compared with IRS (sum score: 180) and ERS (sum score: 174). Comparing 1.5 and 3 T, in particular the overall rating of the IRS technique (sum score: 180) was very similar at both field

  10. Quantitative perfusion imaging in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Zoellner, F.G.; Gaa, T.; Zimmer, F.; Ong, M.M.; Riffel, P.; Hausmann, D.; Schoenberg, S.O.; Weis, M.

    2016-01-01

    Magnetic resonance imaging (MRI) is recognized for its superior tissue contrast while being non-invasive and free of ionizing radiation. Due to the development of new scanner hardware and fast imaging techniques during the last decades, access to tissue and organ functions became possible. One of these functional imaging techniques is perfusion imaging with which tissue perfusion and capillary permeability can be determined from dynamic imaging data. Perfusion imaging by MRI can be performed by two approaches, arterial spin labeling (ASL) and dynamic contrast-enhanced (DCE) MRI. While the first method uses magnetically labelled water protons in arterial blood as an endogenous tracer, the latter involves the injection of a contrast agent, usually gadolinium (Gd), as a tracer for calculating hemodynamic parameters. Studies have demonstrated the potential of perfusion MRI for diagnostics and also for therapy monitoring. The utilization and application of perfusion MRI are still restricted to specialized centers, such as university hospitals. A broad application of the technique has not yet been implemented. The MRI perfusion technique is a valuable tool that might come broadly available after implementation of standards on European and international levels. Such efforts are being promoted by the respective professional bodies. (orig.) [de

  11. Spatial correspondence of 4D CT ventilation and SPECT pulmonary perfusion defects in patients with malignant airway stenosis

    Science.gov (United States)

    Castillo, Richard; Castillo, Edward; McCurdy, Matthew; Gomez, Daniel R.; Block, Alec M.; Bergsma, Derek; Joy, Sarah; Guerrero, Thomas

    2012-04-01

    To determine the spatial overlap agreement between four-dimensional computed tomography (4D CT) ventilation and single photon emission computed tomography (SPECT) perfusion hypo-functioning pulmonary defect regions in a patient population with malignant airway stenosis. Treatment planning 4D CT images were obtained retrospectively for ten lung cancer patients with radiographically demonstrated airway obstruction due to gross tumor volume. Each patient also received a SPECT perfusion study within one week of the planning 4D CT, and prior to the initiation of treatment. Deformable image registration was used to map corresponding lung tissue elements between the extreme component phase images, from which quantitative three-dimensional (3D) images representing the local pulmonary specific ventilation were constructed. Semi-automated segmentation of the percentile perfusion distribution was performed to identify regional defects distal to the known obstructing lesion. Semi-automated segmentation was similarly performed by multiple observers to delineate corresponding defect regions depicted on 4D CT ventilation. Normalized Dice similarity coefficient (NDSC) indices were determined for each observer between SPECT perfusion and 4D CT ventilation defect regions to assess spatial overlap agreement. Tidal volumes determined from 4D CT ventilation were evaluated versus measurements obtained from lung parenchyma segmentation. Linear regression resulted in a linear fit with slope = 1.01 (R2 = 0.99). Respective values for the average DSC, NDSC1 mm and NDSC2 mm for all cases and multiple observers were 0.78, 0.88 and 0.99, indicating that, on average, spatial overlap agreement between ventilation and perfusion defect regions was comparable to the threshold for agreement within 1-2 mm uncertainty. Corresponding coefficients of variation for all metrics were similarly in the range: 0.10%-19%. This study is the first to quantitatively assess 3D spatial overlap agreement between

  12. The multi-slice CT perfusion imaging in evaluating the prevention and treatment by edaravone on lung ischemia-reperfusion injury after pulmonary thromboembolism

    International Nuclear Information System (INIS)

    Li Jianjun; Zhai Renyou; Zhang Dongpo; Huang Qiang; Dai Dingke; Yu Ping; Bao Na

    2008-01-01

    Objective: To evaluate the multi-slice CT perfusion imaging in investigating whether edaravone can prevent and treat pulmonary thromboembolism ischemia-reperfusion injury (PTE-IRI). Methods: Twenty mongrel canines were included. A Swan-Ganz catheter was introduced into the right internal jugular vein using the Seldinger technique, and then was inserted into the pulmonary artery. Balloon occlusion of the right inferior lobe pulmonary artery for 4 h was followed by removing catheter and 4 h o reperfusion. Animals were divided into four groups of A (no edaravone during ischenmia and reperfusion), B (edaravone used only during ischemia), C (edaravone used during both ischemia and reperfusion) and D group (edaravone used only during reperfusion) (n=5 per group). Every group was divided into three time points including before ischemia, 4 h after ischemia and 4 h after reperfusion. CT scan and CT perfusion were performed at the three time points. The blood flow (BF), blood volume (BV) and mean transit time (MTT) of the bilateral inferior regional lung parenchyma were measured with the software of perfusion 3. Results: CT examination showed pulmonary edema in the right inferior lung lobe at 4 h after reperfusion. (1) The BF and MTT of A, B, C and D group were[(259.4±15.7)ml·min -1 ·100 g -1 , (293.7± 7.9) ml·min -1 ·100 g -1 , (379.4±14.5)ml·min -1 ·100 g -1 , (382.5±16.6)ml·min -1 ·. 100 g -1 ] and [(3.1±0.2)s, (2.6±0.2)s, (2.2±0.1)s, (1.9±0.2)s] respectively at 4 h after reperfusion. The BF and MTT were statistically different (P 0.05) at 4 h after reperfusion, but the BV was not statistically different between groups (P>0.05). (2) The BF [(397.2± 19.2)ml·min -1 ·100 g -1 and (259.4±15.7) ml·min -1 ·100 g -1 in group A, (393.2±16.1) ml· min -1 ·100 g -1 and (293.7±7.9) ml·min -1 ·100 g -1 in group B] and MTF [(1.8±0.1)s and (3.1±0.2) s in group A, (1.8±0.2) s and (2.6±0.2) s in group B] were statistically different (P 0.05) between groups

  13. Pulmonary perfusion scintigraphy in the evaluation of the severity of bronchopulmonary dysplasia

    Energy Technology Data Exchange (ETDEWEB)

    Soler, C. [Neonatal Unit, Dept. of Pediatrics, Casa Maternitat Hospital, Clinical Hospital and Sant Joan de Deu Hospital, Univ. of Barcelona (Spain); Figueras, J. [Neonatal Unit, Dept. of Pediatrics, Casa Maternitat Hospital, Clinical Hospital and Sant Joan de Deu Hospital, Univ. of Barcelona (Spain)]|[Servicio de Neonatologia, Hospital Clinico, Barcelona (Spain); Roca, I. [Nuclear Medicine Unit, Autonomous Univ. of Barcelona (Spain); Perez, J.M. [Neonatal Unit, Dept. of Pediatrics, Casa Maternitat Hospital, Clinical Hospital and Sant Joan de Deu Hospital, Univ. of Barcelona (Spain); Jimenez, R. [Neonatal Unit, Dept. of Pediatrics, Casa Maternitat Hospital, Clinical Hospital and Sant Joan de Deu Hospital, Univ. of Barcelona (Spain)

    1997-01-01

    Objective. The objectives of this study were to analyze the changes in pulmonary perfusion in bronchopulmonary dysplasia (BPD) and to assess the advantages of this method in evaluating the severity of BPD. Patients and methods. The study group was made up of 10 children with BPD, matched with a control group of 12 children. The criteria for matching were birth weight, gestational age and need for ventilation for more than 3 days. Clinical and roentgenographic scoring systems were applied on the 21st day of life. At 6 months of corrected age, clinical evolutive severity was evaluated and a pulmonary perfusion scintigraphy using technetium-99 was performed in each child. The scintigraphic findings were classified in five categories ranging from normal to severely affected, depending on the degree and localization of perfusion abnormalities. Another score was obtained by assigning a value from 1 to 5 to each pulmonary lobe, depending on the concentration of the tracer. Results. The study of clinical, roentgenographic and evolutive scores always showed higher values in children with BPD, with good correlation between methods (P < 0.001). In the BPD group, abnormal lung perfusion patterns were more frequent and more severe (P < 0.05), the lobe scoring was higher (P < 0.05), and a lower count rate was found (P < 0.01). Conclusion. Pulmonary scintigraphy is a useful technique in evaluating the severity of BPD. (orig.). With 1 fig., 3 tabs.

  14. Pulmonary perfusion scintigraphy in the evaluation of the severity of bronchopulmonary dysplasia

    International Nuclear Information System (INIS)

    Soler, C.; Figueras, J.; Roca, I.; Perez, J.M.; Jimenez, R.

    1997-01-01

    Objective. The objectives of this study were to analyze the changes in pulmonary perfusion in bronchopulmonary dysplasia (BPD) and to assess the advantages of this method in evaluating the severity of BPD. Patients and methods. The study group was made up of 10 children with BPD, matched with a control group of 12 children. The criteria for matching were birth weight, gestational age and need for ventilation for more than 3 days. Clinical and roentgenographic scoring systems were applied on the 21st day of life. At 6 months of corrected age, clinical evolutive severity was evaluated and a pulmonary perfusion scintigraphy using technetium-99 was performed in each child. The scintigraphic findings were classified in five categories ranging from normal to severely affected, depending on the degree and localization of perfusion abnormalities. Another score was obtained by assigning a value from 1 to 5 to each pulmonary lobe, depending on the concentration of the tracer. Results. The study of clinical, roentgenographic and evolutive scores always showed higher values in children with BPD, with good correlation between methods (P < 0.001). In the BPD group, abnormal lung perfusion patterns were more frequent and more severe (P < 0.05), the lobe scoring was higher (P < 0.05), and a lower count rate was found (P < 0.01). Conclusion. Pulmonary scintigraphy is a useful technique in evaluating the severity of BPD. (orig.). With 1 fig., 3 tabs

  15. Lung perfusion scintigraphy by SPECT

    International Nuclear Information System (INIS)

    Hirayama, Takanobu

    1990-01-01

    The initial study reports the characteristic performance using lung segmental phantom filled in Tc-99m pertechnetate. To evaluate the segmental defect in lung perfusion scintigraphy, we applied Bull's-eye analysis in addition to planar image set. Bull's-eye analysis especially facilitated the interpretation in both middle and lower lobes. Subsequently, to evolute the clinical application of Bull's-eye analysis, pulmonary scintigraphy was performed on 10 normal subjects and 60 patients with several pulmonary diseases. Of interest, Bull's-eye analysis, however, encouraged the interpretation in both lower lobes. To calculate the extention and severity of perfusion defect, the present study describes Bull's-eye analysis. Quantitative scoring showed higher in patients with lung cancer than those with pulmonary tuberculosis. The present study focus that Bull's-eye analysis can be useful for evaluating perfusion in patients with a couple of pulmonary diseases. (author)

  16. Pulmonary embolism in pregnancy: is nuclear medicine imaging still a valid option?

    LENUS (Irish Health Repository)

    Ezwawah, O

    2008-10-01

    In this study we demonstrate our Radiology Department\\'s experience in utilizing low dose (half the normal dose) lung perfusion radionuclide scanning for pregnant patients as the initial investigation for suspected pulmonary embolism (PE). Secondly; we highlight the radiation dose reduction advantages of nuclear medicine imaging over multi-detector computed tomography in this group. We performed a retrospective study of 21 consecutive pregnant women who presented with suspected PE. These patients underwent either lung perfusion scanning or CT pulmonary angiography (CTPA), over a two-year period (May 2005 to July 2007). 19 patients of the cohort studied underwent low dose perfusion-only scintigraphy, with half the usual dose of radionuclide activity. All scans were considered of diagnostic quality. No patient in our study required a ventilation scan. No patient with a negative perfusion scan represented during the 3 month follow up period with PE. We conclude, nuclear medicine imaging is an effective initial investigation for pregnant patients with suspected PE. While scinitigraphy is associated with a greater fetal radiation dose than CTPA, it imparts a lower maternal dose and significantly lower dose to radiosensitive tissues such as breast.

  17. Follow-up of pulmonary perfusion recovery after embolism

    International Nuclear Information System (INIS)

    Palla, A.; Donnamaria, V.; Petruzzelli, S.; Giuntini, C.

    1986-01-01

    Blood flow recovery in a group of 69 patients with pulmonary embolism was followed by serial lung scans over a six month period. Each patient underwent perfusion lung scan at diagnosis then 7, 30 and 180 days later; i.v. heparin was systematically administered for one week after diagnosis, followed by oral warfarin for six months. Blood flow impairment was evaluated by assessing the total number of unperfused lung segments (ULS), as calculated on both lateral views at each scan. The number of ULS was significantly reduced at each interval (P<0.001), ranging from 8.4±3.3 at diagnosis to 3.6±2.7 six months later; most of the recovery (79%) occurred within the first month. No patient had complete restoration of pulmonary blood flow during the whole follow-up period. No difference was found between the number of ULS in right lung versus that in left lung at each interval. Recovery of blood flow was heavily affected by coexisting cardiac or pulmonary disease. In fact, those patients with underlying cardiopulmonary disease (49.2% of the total) showed significantly smaller perfusion improvement after six months (P<0.001). Eight patients (6 with and 2 without cardiopulmonary disease) had clinical and scintigraphic evidence of recurrent embolism during the follow-up period

  18. Compression of the Right Pulmonary Artery by a Massive Defects on Pulmonary Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Makis, William [Brandon Regional Health Centre, Brandon (Canada); Derbekyan, Vilma [McGill Univ. Health Centre, Montreal (Canada)

    2012-03-15

    A 67 year old woman, who presented with a 2 month history of dyspnea, had a vectilation and perfusion lung scan that showed absent perfusion of the entire right lung scan that showed absent perfusion of the entire right lung with normal ventilation, as well as a rounded matched defect in the left lower lung adjacent to mialine, suspicious for an aortic aneurysm or dissection. CT pulmonary angiography revealed a massive descending aortic aneurysm compressing the right pulmonary artery as well as the left lung parenchyma, accounting for the bilateral perfusion scan defects. We present the Xe 133 ventilation, Tc 99m MAA perfusion and CT pulmonary angiography imaging findings of this rare case.

  19. Low pulmonary artery flush perfusion pressure combined with high positive end-expiratory pressure reduces oedema formation in isolated porcine lungs

    International Nuclear Information System (INIS)

    Schumann, Stefan; Schließmann, Stephan J; Wagner, Giskard; Goebel, Ulrich; Priebe, Hans-Joachim; Guttmann, Josef; Kirschbaum, Andreas

    2010-01-01

    Flush perfusion of the pulmonary artery with organ protection solution is a standard procedure before lung explantation. However, rapid flush perfusion may cause pulmonary oedema which is deleterious in the lung transplantation setting. In this study we tested the hypotheses that high pulmonary perfusion pressure contributes to the development of pulmonary oedema and positive end-expiratory pressure (PEEP) counteracts oedema formation. We expected oedema formation to increase weight and decrease compliance of the lungs on the basis of a decrease in alveolar volume as fluid replaces alveolar air spaces. The pulmonary artery of 28 isolated porcine lungs was perfused with a low-potassium dextrane solution at low (mean 27 mmHg) or high (mean 40 mmHg) pulmonary artery pressure (PAP) during mechanical ventilation at low (4 cmH 2 O) or high (8 cmH 2 O) PEEP, respectively. Following perfusion and storage, relative increases in lung weight were smaller (p < 0.05) during perfusion at low PAP (62 ± 32% and 42 ± 26%, respectively) compared to perfusion at high PAP (133 ± 54% and 87 ± 30%, respectively). Compared to all other PAP–PEEP combinations, increases in lung weight were smallest (44 ± 9% and 27 ± 12%, respectively), nonlinear intratidal lung compliance was largest (46% and 17% respectively, both p < 0.05) and lung histology showed least infiltration of mononuclear cells in the alveolar septa, and least alveolar destruction during the combination of low perfusion pressure and high PEEP. The findings suggest that oedema formation during pulmonary artery flush perfusion in isolated and ventilated lungs can be reduced by choosing low perfusion pressure and high PEEP. PAP–PEEP titration to minimize pulmonary oedema should be based on lung mechanics and PAP monitoring

  20. Dual energy CT for the assessment of lung perfusion-Correlation to scintigraphy

    International Nuclear Information System (INIS)

    Thieme, Sven F.; Becker, Christoph R.; Hacker, Marcus; Nikolaou, Konstantin; Reiser, Maximilian F.; Johnson, Thorsten R.C.

    2008-01-01

    Purpose of this study was to determine the diagnostic value of dual energy CT in the assessment of pulmonary perfusion with reference to pulmonary perfusion scintigraphy. Thirteen patients received both dual energy CT (DECT) angiography (Somatom Definition, Siemens) and ventilation/perfusion scintigraphy. Median time between scans was 3 days (range, 0-90). DECT perfusion maps were generated based on the spectral properties of iodine. Two blinded observes assessed DECT angiograms, perfusion maps and scintigrams for presence and location of perfusion defects. The results were compared by patient and by segment, and diagnostic accuracy of DECT perfusion imaging was calculated regarding scintigraphy as standard of reference. Diagnostic accuracy per patient showed 75% sensitivity, 80% specificity and a negative predictive value of 66%. Sensitivity per segment amounted to 83% with 99% specificity, with 93% negative predictive value. Peripheral parts of the lungs were not completely covered by the 80 kVp detector in 85% of patients. CTA identified corresponding emboli in 66% of patients with concordant perfusion defects in DECT and scintigraphy. Dual energy CT perfusion imaging is able to display pulmonary perfusion defects with good agreement to scintigraphic findings. DECT can provide a pulmonary CT angiogram, high-resolution morphology of the lung parenchyma and perfusion information in one single exam

  1. Dual energy CT for the assessment of lung perfusion-Correlation to scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Thieme, Sven F.; Becker, Christoph R. [Department of Clinical Radiology, Ludwig-Maximilians-University of Munich (Germany); Hacker, Marcus [Department of Nuclear Medicine, Ludwig-Maximilians-University of Munich (Germany); Nikolaou, Konstantin; Reiser, Maximilian F. [Department of Clinical Radiology, Ludwig-Maximilians-University of Munich (Germany); Johnson, Thorsten R.C. [Department of Clinical Radiology, Ludwig-Maximilians-University of Munich (Germany)], E-mail: thorsten.johnson@med.uni-muenchen.de

    2008-12-15

    Purpose of this study was to determine the diagnostic value of dual energy CT in the assessment of pulmonary perfusion with reference to pulmonary perfusion scintigraphy. Thirteen patients received both dual energy CT (DECT) angiography (Somatom Definition, Siemens) and ventilation/perfusion scintigraphy. Median time between scans was 3 days (range, 0-90). DECT perfusion maps were generated based on the spectral properties of iodine. Two blinded observes assessed DECT angiograms, perfusion maps and scintigrams for presence and location of perfusion defects. The results were compared by patient and by segment, and diagnostic accuracy of DECT perfusion imaging was calculated regarding scintigraphy as standard of reference. Diagnostic accuracy per patient showed 75% sensitivity, 80% specificity and a negative predictive value of 66%. Sensitivity per segment amounted to 83% with 99% specificity, with 93% negative predictive value. Peripheral parts of the lungs were not completely covered by the 80 kVp detector in 85% of patients. CTA identified corresponding emboli in 66% of patients with concordant perfusion defects in DECT and scintigraphy. Dual energy CT perfusion imaging is able to display pulmonary perfusion defects with good agreement to scintigraphic findings. DECT can provide a pulmonary CT angiogram, high-resolution morphology of the lung parenchyma and perfusion information in one single exam.

  2. The algorithm of imaging diagnostics of pulmonary embolism - time for a new definition?

    International Nuclear Information System (INIS)

    Roberts, H.C.; Kauczor, H.U.; Pitton, M.B.; Schweden, F.; Thelen, M.

    1997-01-01

    Acute pulmonary embolism (PE) is an increasing and underdiagnosed cause of mortality and morbidity in hospitalised patients; pulmonary hypertension based on chronic pulmonary embolism is an uncommon, but severe and surgically curable complication. Since clinical signs might be silent or unspecific, both acute and chronic PE require imaging methods for diagnosis and treatment planning. Chest radiographic findings are usually non-specific. Scintigraphy provides a high sensitivity for PE, but lacks anatomic resolution and sufficient specificity. Pulmonary angiography, albeit accurate, is an invasive procedure associated with low but still not negligible morbidity and mortality. Hence, non-invasive methods offer advantages. Spiral CT, for example, is most reliable in the diagnosis of acute and chronic PE: Such fast CT techniques provide a non-invasive means to detect and differentiate acute emboli and organised thrombi, as well as perfusion abnomalities and other concomitant findings. MRI offers both morphological and functional information on lung perfusion and right heart function, but its image quality still needs improvement to be comparable with CT. Thus, while MRI must still be tested in clinical studies. CT is recommended as a screening method in acute and chronic pulmonary embolism. (orig.) [de

  3. Pulmonary perfusion scintigraphy in children with chronic pulmonary damage: Preliminary results from application of the SPECT technique

    International Nuclear Information System (INIS)

    Lobo S, Gabriel; Ladron de Guevara H, David; Munoz G, Maria Angelica; Araya A, Fernando; Coll C, Claudia; Donoso R, Gilda; Jimenez J, Cesar; Perez R; Andres

    2003-01-01

    The aim was to describe lung perfusion SPECT (LPS) findings in children with chronic pulmonary damage. Material and Method: We revised 106 LPS of children (age:3.9 ± 3.3 yr) with chronic pulmonary damage, performed with a two headed gamma camera. The most common clinical diagnosis were adenovirus bronchopneumonia sequelae (ADV)(29%), unknown origin chronic pulmonary damage (UOPD) (21%), bronchopulmonary dysplasia (BPD)(15%), and chronic obstructed bronchitis (COB)(14%). Severity of pulmonary alterations were evaluated using a Score, which considered extent and type of lung involvement and differential pulmonary perfusion. Pattern of involvement and Score were correlated with diagnosis and gender. Results: Ninety one percent (96/106) of LPS were abnormal (62% boys). Fifty two (54%) showed bilateral alterations, being this finding (p:0.019) more frequent in boys. ADV group showed mainly a mixed bilateral pattern (35%), UOPD a focal unilateral pattern (32%), COB a diffuse unilateral pattern (33%), and BPD a normal pattern (25%). Miscellaneous and UOPD showed the highest score values, and BPD and COB the lowest ones. Conclusion: In this population, LPS is abnormal in high proportion, with some differential characteristics according gender and original diagnosis (au)

  4. Evaluation of Pulmonary Perfusion Scan in Heart Disease

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J T; Kim, C K; Park, C Y; Choi, B S [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1973-09-15

    Pulmonary perfusion scan with radioactive {sup 113m}In-iron hydroxide particle was performed in the 25 cases of heart disease which had been diagnosed by cardiac catheterization prior to surgery from July, 1972 to July, 1973 at the Department of Radiology and Nuclear Medicine, Yonsei Medical College. It consists of 7 mitral stenosis, 2 mitral insufficiency, 1 aortic insufficiency, 3 atrial septal defect, 5 ventricular septal defect, 2 patent ductus arteriosus, 1 transposition of great vessel and 4 Tetralogy of Fallot. Findings of pulmonary perfusion scan in relation to hemodynamic data of cardiac catheterization were examined. 1) Out of 10 cases of acquired valvular heart disease, In 6 cases of stenosis and 1 case of aortic insufficiency, radioactivity was increased at both upper lung. This finding is noted when pulmonary wedge or venous pressure was elevated above 22 mmHg and arterial systolic pressure above 33 mmHg. 2) Out of 15 cases of congenital heart disease. In almost all cases of artial septal defect and ventricular septal defect except 2 cases, radioactivity was even at both entire lung. In 2 cases of patent ductras arteriosus, radioactivity was decreased especially at the left lung. It is observed that in acyanotic congenital heart disease, radioactivity of lung is not related with pulmonary arterial pressure. In 3 cases of Tetralogy of Fallot, radioactivity was even at both entire lung and in 2 of them, extrapulmonary radioactivity of liver or kidney which depends on size of defect and volume of right to left shunt reversible, was noted.

  5. Evaluation of Pulmonary Perfusion Scan in Heart Disease

    International Nuclear Information System (INIS)

    Lee, J. T.; Kim, C. K.; Park, C. Y.; Choi, B. S.

    1973-01-01

    Pulmonary perfusion scan with radioactive 113m In-iron hydroxide particle was performed in the 25 cases of heart disease which had been diagnosed by cardiac catheterization prior to surgery from July, 1972 to July, 1973 at the Department of Radiology and Nuclear Medicine, Yonsei Medical College. It consists of 7 mitral stenosis, 2 mitral insufficiency, 1 aortic insufficiency, 3 atrial septal defect, 5 ventricular septal defect, 2 patent ductus arteriosus, 1 transposition of great vessel and 4 Tetralogy of Fallot. Findings of pulmonary perfusion scan in relation to hemodynamic data of cardiac catheterization were examined. 1) Out of 10 cases of acquired valvular heart disease, In 6 cases of stenosis and 1 case of aortic insufficiency, radioactivity was increased at both upper lung. This finding is noted when pulmonary wedge or venous pressure was elevated above 22 mmHg and arterial systolic pressure above 33 mmHg. 2) Out of 15 cases of congenital heart disease. In almost all cases of artial septal defect and ventricular septal defect except 2 cases, radioactivity was even at both entire lung. In 2 cases of patent ductras arteriosus, radioactivity was decreased especially at the left lung. It is observed that in acyanotic congenital heart disease, radioactivity of lung is not related with pulmonary arterial pressure. In 3 cases of Tetralogy of Fallot, radioactivity was even at both entire lung and in 2 of them, extrapulmonary radioactivity of liver or kidney which depends on size of defect and volume of right to left shunt reversible, was noted.

  6. Chronic thromboembolic pulmonary hypertension (CTEPH). Potential role of multidetector-row CT (MD-CT) and MR imaging in the diagnosis and differential diagnosis of the disease

    Energy Technology Data Exchange (ETDEWEB)

    Wirth, G.; Brueggemann, K.; Bostel, T.; Dueber, C.; Kreitner, K.F. [Universitaetsmedizin Mainz (Germany). Dept. of Radiology; Mayer, E. [Kerckhoff Hospital, Bad Nauheim (Germany). Dept. of Thoracic Surgery

    2014-08-15

    Chronic thromboembolic pulmonary hypertension (CTEPH) can be defined as pulmonary hypertension (resting mean pulmonary arterial pressure of 25 mm Hg or more determined at right heart catheterization) with persistent pulmonary perfusion defects. It is a rare, but underdiagnosed disease with estimated incidences ranging from 0.5% to 3.8% of patients after an acute pulmonary embolism (PE), and in up to 10% of those with a history of recurrent PE. CTEPH is the only form of pulmonary hypertension that can be surgically treated leading to normalization of pulmonary hemodynamics and exercise capacity in the vast majority of patients. The challenges for imaging in patients with suspected CTEPH are fourfold: the imaging modality should have a high diagnostic accuracy with regard to the presence of CTEPH and allow for differential diagnosis. It should enable detection of patients suitable for PEA with great certainty, and allow for quantification of PH by measuring pulmonary hemodynamics (mPAP and PVR), and finally, it can be used for therapy monitoring. This overview tries to elucidate the potential role of ECG-gated multidetector CT pulmonary angiography (MD-CTPA) and MR imaging, and summarizes the most important results that have been achieved so far. Generally speaking, ECG-gated MD-CTPA is superior to MR in the assessment of parenchymal and vascular pathologies of the lung, and allows for the assessment of cardiac structures. The implementation of iodine maps as a surrogate for lung perfusion enables functional assessment of lung perfusion by CT. MR imaging is the reference standard for the assessment of right heart function and lung perfusion, the latter delineating typical wedge-shaped perfusion defects in patients with CTEPH. New developments show that with MR techniques, an estimation of hemodynamic parameters like mean pulmonary arterial pressure and pulmonary vascular resistance will be possible. CT and MR imaging should be considered as complementary

  7. A diagnostic strategy for pulmonary embolism based on standardised pretest probability and perfusion lung scanning: a management study

    International Nuclear Information System (INIS)

    Miniati, Massimo; Monti, Simonetta; Bauleo, Carolina; Scoscia, Elvio; Tonelli, Lucia; Dainelli, Alba; Catapano, Giosue; Formichi, Bruno; Di Ricco, Giorgio; Prediletto, Renato; Carrozzi, Laura; Marini, Carlo

    2003-01-01

    Pulmonary embolism remains a challenging diagnostic problem. We developed a simple diagnostic strategy based on combination of assessment of the pretest probability with perfusion lung scan results to reduce the need for pulmonary angiography. We studied 390 consecutive patients (78% in-patients) with suspected pulmonary embolism. The pretest probability was rated low ( 10%, ≤50%), moderately high (>50%, ≤90%) or high (>90%) according to a structured clinical model. Perfusion lung scans were independently assigned to one of four categories: normal; near-normal; abnormal, suggestive of pulmonary embolism (wedge-shaped perfusion defects); abnormal, not suggestive of pulmonary embolism (perfusion defects other than wedge shaped). Pulmonary embolism was diagnosed in patients with abnormal scans suggestive of pulmonary embolism and moderately high or high pretest probability. Patients with normal or near-normal scans and those with abnormal scans not suggestive of pulmonary embolism and low pretest probability were deemed not to have pulmonary embolism. All other patients were allocated to pulmonary angiography. Patients in whom pulmonary embolism was excluded were left untreated. All patients were followed up for 1 year. Pulmonary embolism was diagnosed non-invasively in 132 patients (34%), and excluded in 191 (49%). Pulmonary angiography was required in 67 patients (17%). The prevalence of pulmonary embolism was 41% (n=160). Patients in whom pulmonary embolism was excluded had a thrombo-embolic risk of 0.4% (95% confidence interval: 0.0%-2.8%). Our strategy permitted a non-invasive diagnosis or exclusion of pulmonary embolism in 83% of the cases (95% confidence interval: 79%-86%), and appeared to be safe. (orig.)

  8. Changes in perfusion scintigraphy in the first days of heparin therapy in patients with acute pulmonary embolism

    NARCIS (Netherlands)

    de Groot, M. R.; Oostdijk, A. H.; Engelage, A. H.; van Marwijk Kooy, M.; Büller, H. R.

    2000-01-01

    Patients with suspected pulmonary embolism often receive heparin therapy for hours to days before ventilation/perfusion scintigraphy is completed. We assessed to what extent the lung scan classification and pulmonary vascular perfusion changed over a period of 2-4 days of full anticoagulant therapy.

  9. Methodology for ventilation/perfusion SPECT

    DEFF Research Database (Denmark)

    Bajc, Marika; Neilly, Brian; Miniati, Massimo

    2010-01-01

    radiolabeled liquid aerosols are not restricted to the presence of obstructive lung disease. Radiolabeled macroaggregated human albumin is the imaging agent of choice for perfusion scintigraphy. An optimal combination of nuclide activities and acquisition times for ventilation and perfusion, collimators......Ventilation/perfusion single-photon emission computed tomography (V/Q SPECT) is the scintigraphic technique of choice for the diagnosis of pulmonary embolism and many other disorders that affect lung function. Data from recent ventilation studies show that the theoretic advantages of Technegas over......, and imaging matrix yields an adequate V/Q SPECT study in approximately 20 minutes of imaging time. The recommended protocol based on the patient remaining in an unchanged position during the initial ventilation study and the perfusion study allows presentation of matching ventilation and perfusion slices...

  10. 3D pulmonary perfusion MRI and MR angiography of pulmonary embolism in pigs after a single injection of a blood pool MR contrast agent

    International Nuclear Information System (INIS)

    Fink, Christian; Ley, Sebastian; Puderbach, Michael; Plathow, Christian; Kauczor, Hans-Ulrich; Bock, Michael

    2004-01-01

    The purpose of this study was to assess the feasibility of contrast-enhanced 3D perfusion MRI and MR angiography (MRA) of pulmonary embolism (PE) in pigs using a single injection of the blood pool contrast Gadomer. PE was induced in five domestic pigs by injection of autologous blood thrombi. Contrast-enhanced first-pass 3D perfusion MRI (TE/TR/FA: 1.0 ms/2.2 ms/40 ; voxel size: 1.3 x 2.5 x 4.0 mm 3 ; TA: 1.8 s per data set) and high-resolution 3D MRA (TE/TR/FA: 1.4 ms/3.4 ms/40 ; voxel size: 0.8 x 1.0 x 1.6 mm 3 ) was performed during and after a single injection of 0.1 mmol/kg body weight of Gadomer. Image data were compared to pre-embolism Gd-DTPA-enhanced MRI and post-embolism thin-section multislice CT (n=2). SNR measurements were performed in the pulmonary arteries and lung. One animal died after induction of PE. In all other animals, perfusion MRI and MRA could be acquired after a single injection of Gadomer. At perfusion MRI, PE could be detected by typical wedge-shaped perfusion defects. While the visualization of central PE at MRA correlated well with the CT, peripheral PE were only visualized by CT. Gadomer achieved a higher peak SNR of the lungs compared to Gd-DTPA (21±8 vs. 13±3). Contrast-enhanced 3D perfusion MRI and MRA of PE can be combined using a single injection of the blood pool contrast agent Gadomer. (orig.)

  11. Magnetic resonance perfusion imaging without contrast media

    International Nuclear Information System (INIS)

    Martirosian, Petros; Graf, Hansjoerg; Schick, Fritz; Boss, Andreas; Schraml, Christina; Schwenzer, Nina F.; Claussen, Claus D.

    2010-01-01

    Principles of magnetic resonance imaging techniques providing perfusion-related contrast weighting without administration of contrast media are reported and analysed systematically. Especially common approaches to arterial spin labelling (ASL) perfusion imaging allowing quantitative assessment of specific perfusion rates are described in detail. The potential of ASL for perfusion imaging was tested in several types of tissue. After a systematic comparison of technical aspects of continuous and pulsed ASL techniques the standard kinetic model and tissue properties of influence to quantitative measurements of perfusion are reported. For the applications demonstrated in this paper a flow-sensitive alternating inversion recovery (FAIR) ASL perfusion preparation approach followed by true fast imaging with steady precession (true FISP) data recording was developed and implemented on whole-body scanners operating at 0.2, 1.5 and 3 T for quantitative perfusion measurement in various types of tissue. ASL imaging provides a non-invasive tool for assessment of tissue perfusion rates in vivo. Images recorded from kidney, lung, brain, salivary gland and thyroid gland provide a spatial resolution of a few millimetres and sufficient signal to noise ratio in perfusion maps after 2-5 min of examination time. Newly developed ASL techniques provide especially high image quality and quantitative perfusion maps in tissues with relatively high perfusion rates (as also present in many tumours). Averaging of acquisitions and image subtraction procedures are mandatory, leading to the necessity of synchronization of data recording to breathing in abdominal and thoracic organs. (orig.)

  12. Pulmonary perfusion ''without ventilation''

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, C.N.; Sziklas, J.J.; Spencer, R.P.; Rosenberg, R.J.

    1983-12-01

    An 88-yr-old man, with prior left upper lobectomy and phrenic nerve injury, had a ventilation/perfusion lung image. Both wash-in and equilibrium ventilation images showed no radioactive gas in the left lung. Nevertheless, the left lung was perfused. A similar result was obtained on a repeat study 8 days later. Delayed images, during washout, showed some radioactive gas in the left lung. Nearly absent ventilation (but continued perfusion) of that lung might have been related to altered gas dynamics brought about by the prior lobectomy, a submucosal bronchial lesion, phrenic nerve damage, and limited motion of the left part of the diaphragm. This case raises the issue of the degree of ventilation (and the phase relationship between the lungs) required for the entry of radioactive gas into a diseased lung, and the production of a ''reversed ventilation/perfusion mismatch.''

  13. Evaluation of mosaic pattern areas in HRCT with Min-IP reconstructions in patients with pulmonary hypertension: Could this evaluation replace lung perfusion scintigraphy?

    International Nuclear Information System (INIS)

    Rossi, A.; Attinà, D.; Borgonovi, A.; Buia, F.; De Luca, F.; Guidalotti, P.L.; Fughelli, P.; Galiè, N.; Zompatori, M.

    2012-01-01

    Purpose: The aim of this study is to evaluate a possible correlation between areas of lung attenuation, found in minimum intensity projection (Min-IP) reconstruction images performed with high resolution computed tomography without contrast medium (HRCT), and areas of lung perfusion alteration, found in lung perfusion scintigraphy (LPS). Materials and methods: Two independent radiologists, unaware of LPS results, evaluated retrospectively a group of 113 patients affected by pulmonary hypertension (HP) of different aetiology. These have been examined in a period of two years in our centre both by spiral computed tomography (CT) with and without contrast-medium and by LPS. The final diagnosis was determined on clinical data, right heart catheterisation and contrast enhanced CT in angiographic phase (CTPA). We reconstructed the Min-IP images of lung parenchyma in all the cases both in HRCT without contrast-medium, and in contrast enhanced CT in angiographic phase (CTPA) in axial, sagittal and coronal planes. The obtained images were qualitatively graded into three categories of pulmonary attenuation: homogeneous, inhomogeneous with non-segmental patchy defects, inhomogeneous with segmental defects. The same criteria of classification were used also for LPS images. In the group of patients with chronic thromboembolic pulmonary hypertension (CTEPH) we also compared the number of areas of lung attenuation found in Min-IP images in HRCT without contrast-medium, and their exact localization, with not perfused areas in LPS. Gold standard for the diagnosis of pulmonary embolism was spiral contrast enhanced CT in angiographic phase (CTPA). Results: In all cases we found exact correspondence between the Min-IP images in HRCT with and without contras agent. The attenuation pattern seen on Min-IP images was concordant with those of LPS in 96 out of 113 patients (85%). In the remaining 17 cases (15%) it was discordant: in 12 cases inhomogeneous in Min-IP images (7 with non

  14. The role of lung imaging in pulmonary embolism

    Science.gov (United States)

    Mishkin, Fred S.; Johnson, Philip M.

    1973-01-01

    The advantages of lung scanning in suspected pulmonary embolism are its diagnostic sensitivity, simplicity and safety. The ability to delineate regional pulmonary ischaemia, to quantitate its extent and to follow its response to therapy provides valuable clinical data available by no other simple means. The negative scan effectively excludes pulmonary embolism but, although certain of its features favour the diagnosis of embolism, the positive scan inherently lacks specificity and requires angiographic confirmation when embolectomy, caval plication or infusion of a thrombolytic agent are contemplated. The addition of simple ventilation imaging techniques with radioxenon overcomes this limitation by providing accurate analog estimation or digital quantitation of regional ventilation: perfusion (V/Q) ratios fundamental to understanding the pathophysiologic consequences of embolism and other diseases of the lung. ImagesFig. 1Fig. 2Fig. 3Fig. 4Fig. 5Fig. 6Fig. 7p495-bFig. 8Fig. 9Fig. 10Fig. 11Fig. 12Fig. 13 PMID:4602128

  15. Detection of pulmonary embolism with combined ventilation-perfusion SPECT and low-dose CT: head-to-head comparison with multidetector CT angiography

    DEFF Research Database (Denmark)

    Gutte, Henrik; Mortensen, Jann; Jensen, Claus Verner

    2009-01-01

    The diagnosis of pulmonary embolism (PE) is usually established by a combination of clinical assessment, D-dimer testing, and imaging with either pulmonary ventilation-perfusion (V/Q) scintigraphy or pulmonary multidetector CT (MDCT) angiography. Both V/Q SPECT and MDCT angiography seem to have...... high diagnostic accuracy. However, only limited data directly comparing these 2 modalities are available. Hybrid gamma-camera/MDCT systems have been introduced and allow simultaneous 3-dimensional lung V/Q SPECT and MDCT angiography, suitable for diagnosing PE. The aim of our study was to compare...

  16. Lung Perfusion SPECT: Application in a Patient With Tetralogy of Fallot and Suspected Pulmonary Thromboemboli

    International Nuclear Information System (INIS)

    Ranji Amjad, Mina; Abbasi, Mehrshad; Farzanehfar, Saeed

    2015-01-01

    A 22-year-old woman presented with acute left-sided pleuritic chest pain and dyspnea 6 days after surgery for revision of the stenotic central aortopulmonary shunt. She had a history of tetralogy of Fallot (TOF), pulmonary valve stenosis, ventricular septal defect and major aortopulmonary collateral artery. Her Waterston shunt was placed when she was 5 years old and stented and re-dilated after stenosis. Acute pulmonary thromboemboli (PTE) was suspected and pulmonary perfusion scan was performed with 4 mCi 99m Technetium labeled macroaggregated albumin. The left lung was globally hypoperfused with evident uptake in the brain, renal parenchyma and thyroid. SPECT images revealed a segmental wedge-shaped peripheral defect in the posterior segment of the left upper lobe. The scan was interpreted as acute/chronic PTE or vascular abnormality. CT angiography excluded PTE; nevertheless the patient was treated with a therapeutic dose of heparin changed to warfarin and was discharged with improvement of the symptoms. Pulmonary artery angiography was not performed

  17. Differentiation of malignant and benign pulmonary nodules with first-pass dual-input perfusion CT

    International Nuclear Information System (INIS)

    Yuan, Xiaodong; Quan, Changbin; Cao, Jianxia; Ao, Guokun; Tian, Yuan; Li, Hong; Zhang, Jing

    2013-01-01

    To assess diagnostic performance of dual-input CT perfusion for distinguishing malignant from benign solitary pulmonary nodules (SPNs). Fifty-six consecutive subjects with SPNs underwent contrast-enhanced 320-row multidetector dynamic volume CT. The dual-input maximum slope CT perfusion analysis was employed to calculate the pulmonary flow (PF), bronchial flow (BF), and perfusion index (PI,=PF/(PF+BF)). Differences in perfusion parameters between malignant and benign tumours were assessed with histopathological diagnosis as the gold standard. Diagnostic value of the perfusion parameters was calculated using the receiver-operating characteristic (ROC) curve analysis. Amongst 56 SPNs, statistically significant differences in all three perfusion parameters were revealed between malignant and benign tumours. The PI demonstrated the biggest difference between malignancy and benignancy: 0.30 ± 0.07 vs. 0.51 ± 0.13, P < 0.001. The area under the PI ROC curve was 0.92, the largest of the three perfusion parameters, producing a sensitivity of 0.95, specificity of 0.83, positive likelihood ratio (+LR) of 5.59, and negative likelihood ratio (-LR) of 0.06 in identifying malignancy. The PI derived from the dual-input maximum slope CT perfusion analysis is a valuable biomarker for identifying malignancy in SPNs. PI may be potentially useful for lung cancer treatment planning and forecasting the therapeutic effect of radiotherapy treatment. (orig.)

  18. Pulmonary vascular volume ratio measured by cardiac computed tomography in children and young adults with congenital heart disease: comparison with lung perfusion scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo; Park, Sang Hyub [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of)

    2017-11-15

    Lung perfusion scintigraphy is regarded as the gold standard for evaluating differential lung perfusion ratio in congenital heart disease. To compare cardiac CT with lung perfusion scintigraphy for estimated pulmonary vascular volume ratio in patients with congenital heart disease. We included 52 children and young adults (median age 4 years, range 2 months to 28 years; 31 males) with congenital heart disease who underwent cardiac CT and lung perfusion scintigraphy without an interim surgical or transcatheter intervention and within 1 year. We calculated the right and left pulmonary vascular volumes using threshold-based CT volumetry. Then we compared right pulmonary vascular volume percentages at cardiac CT with right lung perfusion percentages at lung perfusion scintigraphy by using paired t-test and Bland-Altman analysis. The right pulmonary vascular volume percentages at cardiac CT (66.3 ± 14.0%) were significantly smaller than the right lung perfusion percentages at lung perfusion scintigraphy (69.1 ± 15.0%; P=0.001). Bland-Altman analysis showed a mean difference of -2.8 ± 5.8% and 95% limits of agreement (-14.1%, 8.5%) between these two variables. Cardiac CT, in a single examination, can offer pulmonary vascular volume ratio in addition to pulmonary artery anatomy essential for evaluating peripheral pulmonary artery stenosis in patients with congenital heart disease. However there is a wide range of agreement between cardiac CT and lung perfusion scintigraphy. (orig.)

  19. Pulmonary vascular volume ratio measured by cardiac computed tomography in children and young adults with congenital heart disease: comparison with lung perfusion scintigraphy

    International Nuclear Information System (INIS)

    Goo, Hyun Woo; Park, Sang Hyub

    2017-01-01

    Lung perfusion scintigraphy is regarded as the gold standard for evaluating differential lung perfusion ratio in congenital heart disease. To compare cardiac CT with lung perfusion scintigraphy for estimated pulmonary vascular volume ratio in patients with congenital heart disease. We included 52 children and young adults (median age 4 years, range 2 months to 28 years; 31 males) with congenital heart disease who underwent cardiac CT and lung perfusion scintigraphy without an interim surgical or transcatheter intervention and within 1 year. We calculated the right and left pulmonary vascular volumes using threshold-based CT volumetry. Then we compared right pulmonary vascular volume percentages at cardiac CT with right lung perfusion percentages at lung perfusion scintigraphy by using paired t-test and Bland-Altman analysis. The right pulmonary vascular volume percentages at cardiac CT (66.3 ± 14.0%) were significantly smaller than the right lung perfusion percentages at lung perfusion scintigraphy (69.1 ± 15.0%; P=0.001). Bland-Altman analysis showed a mean difference of -2.8 ± 5.8% and 95% limits of agreement (-14.1%, 8.5%) between these two variables. Cardiac CT, in a single examination, can offer pulmonary vascular volume ratio in addition to pulmonary artery anatomy essential for evaluating peripheral pulmonary artery stenosis in patients with congenital heart disease. However there is a wide range of agreement between cardiac CT and lung perfusion scintigraphy. (orig.)

  20. Pulmonary vascular volume ratio measured by cardiac computed tomography in children and young adults with congenital heart disease: comparison with lung perfusion scintigraphy.

    Science.gov (United States)

    Goo, Hyun Woo; Park, Sang Hyub

    2017-11-01

    Lung perfusion scintigraphy is regarded as the gold standard for evaluating differential lung perfusion ratio in congenital heart disease. To compare cardiac CT with lung perfusion scintigraphy for estimated pulmonary vascular volume ratio in patients with congenital heart disease. We included 52 children and young adults (median age 4 years, range 2 months to 28 years; 31 males) with congenital heart disease who underwent cardiac CT and lung perfusion scintigraphy without an interim surgical or transcatheter intervention and within 1 year. We calculated the right and left pulmonary vascular volumes using threshold-based CT volumetry. Then we compared right pulmonary vascular volume percentages at cardiac CT with right lung perfusion percentages at lung perfusion scintigraphy by using paired t-test and Bland-Altman analysis. The right pulmonary vascular volume percentages at cardiac CT (66.3 ± 14.0%) were significantly smaller than the right lung perfusion percentages at lung perfusion scintigraphy (69.1 ± 15.0%; P=0.001). Bland-Altman analysis showed a mean difference of -2.8 ± 5.8% and 95% limits of agreement (-14.1%, 8.5%) between these two variables. Cardiac CT, in a single examination, can offer pulmonary vascular volume ratio in addition to pulmonary artery anatomy essential for evaluating peripheral pulmonary artery stenosis in patients with congenital heart disease. However there is a wide range of agreement between cardiac CT and lung perfusion scintigraphy.

  1. Functional Mechanism of Lung Mosaic CT Attenuation: Assessment with Deep-Inspiration Breath-Hold Perfusion SPECT-CT Fusion Imaging and Non-Breath-Hold Technegas SPECT

    International Nuclear Information System (INIS)

    Suga, K.; Yasuhiko, K.; Iwanaga, H.; Tokuda, O.; Matsunaga, N.

    2009-01-01

    Background: The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. Purpose: To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Material and Methods: Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. Results: On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Conclusion: Although further validation is

  2. Functional Mechanism of Lung Mosaic CT Attenuation: Assessment with Deep-Inspiration Breath-Hold Perfusion SPECT-CT Fusion Imaging and Non-Breath-Hold Technegas SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Suga, K.; Yasuhiko, K. (Dept. of Radiology, St. Hill Hospital, Ube, Yamaguchi (Japan)); Iwanaga, H.; Tokuda, O.; Matsunaga, N. (Dept. of Radiology, Yamaguchi Univ. School of Medicine, Ube, Yamaguchi (Japan))

    2009-01-15

    Background: The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. Purpose: To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Material and Methods: Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. Results: On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Conclusion: Although further validation is

  3. Functional mechanism of lung mosaic CT attenuation: assessment with deep-inspiration breath-hold perfusion SPECT-CT fusion imaging and non-breath-hold Technegas SPECT.

    Science.gov (United States)

    Suga, K; Yasuhiko, K; Iwanaga, H; Tokuda, O; Matsunaga, N

    2009-01-01

    The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Although further validation is required, our results indicate that heterogeneous pulmonary arterial

  4. Pulmonary scintigraphy using 197HgCl2 and pulmonary perfusion scintigraphy in bronchopulmonary diseases

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Kanai, Hisakata; Handa, Kenjiro; Kusama, Shozo

    1981-01-01

    75 patients with pulmonary tuberculosis and 106 patients with bronchopulmonary diseases whose chest x-rays showed diffuse shadows were studied. Pulmonary scintigraphy using 197 HgCl 2 was useful for the diagnosis of the localization and the activity of pulmonary tuberculosis, because 197 HgCl 2 readily accumulated in the foci, and its accumulation rate was related to the activity of the foci. 197 HgCl 2 also accumulated markedly in foci of pneumoconiosis, especially, in areas showing large shadows and foci suspected to be tuberculosis. 197 HgCl 2 also accumulated in areas of chronic bronchitis, diffuse interstitial pneumonia and bronchiectasis. Its accumulation was considered to have a relation to the activity of inflammation. In primary pulmonary carcinoma, 197 HgCl 2 accumulated most markedly, in the primary lesions. 197 HgCl 2 also accumulated in metastatic or invasion areas of the hilus and the mediastinum. It accumulated in intrapulmonary metastatic foci of pulmonary carcinoma and multiple metastatic pulmonary tumors, but it was difficult to differentiate these diseases from other pulmonary diseases. In selected cases, it was useful to use pulmonary scintigraphy using 197 HgCl 2 together with pulmonary perfusion scintigraphy for the diagnosis of diffuse bronchopulmonary diseases. (Tsunoda, M.)

  5. Pulmonary O2 transfer during pulsatile and non-pulsatile perfusion.

    Science.gov (United States)

    Hauge, A; Nicolaysen, G

    1980-07-01

    The importance of the perfusion pattern for the oxygen transfer has been examined in isolated rabbit lungs perfused with plasma at constant volume inflow. The lungs were ventilated with constant tidal volume and constant end-expiratory pressure. Following a standardized rise in FIO2 the rate of rise in pulmonary venous PO2 (delta PO2/delta t) was measured during alternately pulsatile and non-pulsatile perfusion in normal lungs and in lungs made edematous by elevation of left atrial pressure. In normal lungs there was no difference in delta PO2/delta t when the two modes of perfusion were compared. In edematous lungs delta PO/delta t was statistically higher during pulsatile perfusion, indicating a beneficial effect of flow- and pressure pulsations, e.g. a better distribution of V/Q ratios throughout the lungs. In a separate series of expts. the advancement of a high O2 front through the airways was measured, and the two perfusion patterns compared. Since no difference was found, we suggest that the phenomenon of "cardiogenic gas mixing" in the airways in vivo is a result of a direct action of the heart on the lungs rather than arterial pulsations.

  6. A review of imaging modalities in pulmonary hypertension

    Directory of Open Access Journals (Sweden)

    Mona Ascha

    2017-01-01

    Full Text Available Pulmonary hypertension (PH is defined as resting mean pulmonary artery pressure ≥25 mmHg measured by right heart catheterization. PH is a progressive, life-threatening disease with a variety of etiologies. Swift and accurate diagnosis of PH and appropriate classification in etiologic group will allow for earlier treatment and improved outcomes. A number of imaging tools are utilized in the evaluation of PH, such as chest X-ray, computed tomography (CT, ventilation/perfusion (V/Q scan, and cardiac magnetic resonance imaging. Newer imaging tools such as dual-energy CT and single-photon emission computed tomography/computed tomography V/Q scanning have also emerged; however, their place in the diagnostic evaluation of PH remains to be determined. In general, each imaging technique provides incremental information, with varying degrees of sensitivity and specificity, which helps suspect the presence and identify the etiology of PH. The present study aims to provide a comprehensive review of the utility, advantages, and shortcomings of the imaging modalities that may be used to evaluate patients with PH.

  7. Diagnostic accuracy of contrast-enhanced MR angiography and unenhanced proton MR imaging compared with CT pulmonary angiography in chronic thromboembolic pulmonary hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Rajaram, Smitha [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Academic Unit of Radiology, C Floor, Royal Hallamshire Hospital, Sheffield (United Kingdom); Swift, Andrew J.; Wild, Jim M. [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Sheffield Cardiovascular Biomedical Research Unit, Sheffield (United Kingdom); Capener, David; Telfer, Adam [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Davies, Christine; Hill, Catherine [Sheffield Teaching Hospitals Trust, Department of Radiology, Sheffield (United Kingdom); Condliffe, Robin; Elliot, Charles; Kiely, David G. [Sheffield Pulmonary Vascular Disease Unit, Royal Hallamshire Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield (United Kingdom); Sheffield Cardiovascular Biomedical Research Unit, Sheffield (United Kingdom); Hurdman, Judith [Sheffield Pulmonary Vascular Disease Unit, Royal Hallamshire Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield (United Kingdom)

    2012-02-15

    To evaluate the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) and the added benefit of unenhanced proton MR angiography compared with CT pulmonary angiography (CTPA) in patients with chronic thromboembolic disease (CTE). A 2 year retrospective study of 53 patients with chronic thromboembolic pulmonary hypertension who underwent CTPA and MRI for suspected pulmonary hypertension and a control group of 36 patients with no CT evidence of pulmonary embolism. The MRI was evaluated for CTE and the combined diagnostic accuracy of ce-MRA and unenhanced proton MRA was determined. CE-MRA generated lung perfusion maps were also assessed. The overall sensitivity and specificity of CE-MRA in diagnosing proximal and distal CTE were 98% and 94%, respectively. The sensitivity improved from 50% to 88% for central vessel disease when CE-MRA images were analysed with unenhanced proton MRA. The CE-MRA identified more stenoses (29/18), post-stenosis dilatation (23/7) and occlusions (37/29) compared with CTPA. The CE-MRA perfusion images showed a sensitivity of 92% for diagnosing CTE. CE-MRA has high sensitivity and specificity for diagnosing CTE. The sensitivity of CE-MRA for visualisation of adherent central and lobar thrombus significantly improves with the addition of unenhanced proton MRA which delineates the vessel wall. (orig.)

  8. Diagnostic accuracy of contrast-enhanced MR angiography and unenhanced proton MR imaging compared with CT pulmonary angiography in chronic thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Rajaram, Smitha; Swift, Andrew J.; Wild, Jim M.; Capener, David; Telfer, Adam; Davies, Christine; Hill, Catherine; Condliffe, Robin; Elliot, Charles; Kiely, David G.; Hurdman, Judith

    2012-01-01

    To evaluate the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) and the added benefit of unenhanced proton MR angiography compared with CT pulmonary angiography (CTPA) in patients with chronic thromboembolic disease (CTE). A 2 year retrospective study of 53 patients with chronic thromboembolic pulmonary hypertension who underwent CTPA and MRI for suspected pulmonary hypertension and a control group of 36 patients with no CT evidence of pulmonary embolism. The MRI was evaluated for CTE and the combined diagnostic accuracy of ce-MRA and unenhanced proton MRA was determined. CE-MRA generated lung perfusion maps were also assessed. The overall sensitivity and specificity of CE-MRA in diagnosing proximal and distal CTE were 98% and 94%, respectively. The sensitivity improved from 50% to 88% for central vessel disease when CE-MRA images were analysed with unenhanced proton MRA. The CE-MRA identified more stenoses (29/18), post-stenosis dilatation (23/7) and occlusions (37/29) compared with CTPA. The CE-MRA perfusion images showed a sensitivity of 92% for diagnosing CTE. CE-MRA has high sensitivity and specificity for diagnosing CTE. The sensitivity of CE-MRA for visualisation of adherent central and lobar thrombus significantly improves with the addition of unenhanced proton MRA which delineates the vessel wall. (orig.)

  9. Assessment of the relationship between morphological emphysema phenotype and corresponding pulmonary perfusion pattern on a segmental level

    International Nuclear Information System (INIS)

    Bryant, Mark; Kauczor, Hans-Ulrich; Ley, Sebastian; Eberhardt, Ralf; Herth, Felix; Menezes, Ravi; Sedlaczek, Oliver; Ley-Zaporozhan, Julia

    2015-01-01

    Distinct morphological emphysema phenotypes were assessed by CT to show characteristic perfusion defect patterns. Forty-one patients with severe emphysema (GOLD III/IV) underwent three-dimensional high resolution computed tomography (3D-HRCT) and contrast-enhanced magnetic resonance (MR) perfusion. 3D-HRCT data was visually analyzed for emphysema phenotyping and quantification by consensus of three experts in chest-radiology. The predominant phenotype per segment was categorized as normal, centrilobular, panlobular or paraseptal. Segmental lung perfusion was visually analyzed using six patterns of pulmonary perfusion (1-normal; 2-mild homogeneous reduction in perfusion; 3-heterogeneous perfusion without focal defects; 4-heterogeneous perfusion with focal defects; 5-heterogeneous absence of perfusion; 6-homogeneous absence of perfusion), with the extent of the defect given as a percentage. 730 segments were evaluated. CT categorized 566 (78 %) as centrilobular, 159 (22 %) as panlobular and 5 (<1 %) as paraseptal with no normals. Scores with regards to MR perfusion patterns were: 1-0; 2-0; 3-28 (4 %); 4-425 (58 %); 5-169 (23 %); 6-108 (15 %). The predominant perfusion pattern matched as follows: 70 % centrilobular emphysema - heterogeneous perfusion with focal defects (score 4); 42 % panlobular - homogeneous absence of perfusion (score 5); and 43 % panlobular - heterogeneous absence of perfusion (score 6). MR pulmonary perfusion patterns correlate with the CT phenotype at a segmental level in patients with severe emphysema. (orig.)

  10. Assessment of the relationship between morphological emphysema phenotype and corresponding pulmonary perfusion pattern on a segmental level

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, Mark; Kauczor, Hans-Ulrich [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Member of German Lung Research Center DZL, Translational Lung Research Center TLRC-H, Heidelberg (Germany); Ley, Sebastian [Chirurgische Klinik Dr. Rinecker, Department of Diagnostic and Interventional Radiology, Munich (Germany); Ludwig Maximilians University, Department of Clinical Radiology, Munich (Germany); Eberhardt, Ralf; Herth, Felix [Thoraxklinik University of Heidelberg, Department of Pneumology and Critical Care Medicine, Heidelberg (Germany); Member of German Lung Research Center DZL, Translational Lung Research Center TLRC-H, Heidelberg (Germany); Menezes, Ravi [University of Toronto, Medical Imaging, Toronto (Canada); Sedlaczek, Oliver [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Member of German Lung Research Center DZL, Translational Lung Research Center TLRC-H, Heidelberg (Germany); Ley-Zaporozhan, Julia [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Ludwig Maximilians University, Department of Clinical Radiology, Munich (Germany)

    2015-01-15

    Distinct morphological emphysema phenotypes were assessed by CT to show characteristic perfusion defect patterns. Forty-one patients with severe emphysema (GOLD III/IV) underwent three-dimensional high resolution computed tomography (3D-HRCT) and contrast-enhanced magnetic resonance (MR) perfusion. 3D-HRCT data was visually analyzed for emphysema phenotyping and quantification by consensus of three experts in chest-radiology. The predominant phenotype per segment was categorized as normal, centrilobular, panlobular or paraseptal. Segmental lung perfusion was visually analyzed using six patterns of pulmonary perfusion (1-normal; 2-mild homogeneous reduction in perfusion; 3-heterogeneous perfusion without focal defects; 4-heterogeneous perfusion with focal defects; 5-heterogeneous absence of perfusion; 6-homogeneous absence of perfusion), with the extent of the defect given as a percentage. 730 segments were evaluated. CT categorized 566 (78 %) as centrilobular, 159 (22 %) as panlobular and 5 (<1 %) as paraseptal with no normals. Scores with regards to MR perfusion patterns were: 1-0; 2-0; 3-28 (4 %); 4-425 (58 %); 5-169 (23 %); 6-108 (15 %). The predominant perfusion pattern matched as follows: 70 % centrilobular emphysema - heterogeneous perfusion with focal defects (score 4); 42 % panlobular - homogeneous absence of perfusion (score 5); and 43 % panlobular - heterogeneous absence of perfusion (score 6). MR pulmonary perfusion patterns correlate with the CT phenotype at a segmental level in patients with severe emphysema. (orig.)

  11. Analysis of perfusion defects by causes other than acute pulmonary thromboembolism on contrast-enhanced dual-energy CT in consecutive 537 patients

    International Nuclear Information System (INIS)

    Kim, Bo Hyun; Seo, Joon Beom; Chae, Eun Jin; Lee, Hyun Joo; Hwang, Hye Jeon; Lim, Chaehun

    2012-01-01

    Objective: To assess causes, incidence and patterns of perfusion defects (PDs) on dual-energy perfusion CT angiography (DECTA) in clinically suspected acute pulmonary thromboembolisms (PTE). Materials and methods: Consecutive 537 patients who underwent DECTA for suspicion of PTE were retrospectively reviewed. After excluding patients with possible PTE or unsatisfactory perfusion map quality, 299 patients with 1697 lobes were included. The DECTA (Somatom Definition, Siemens) was performed at 140 kV and 80 kV. Color-coded perfusion images were obtained with a lung PBV application of the workstation software (Syngo Dual Energy). The presence, incidence, three patterns of PDs (wedge-shaped, heterogeneous, and regionally homogeneous), pulmonary diseases, and the matchedness between the PD and the disease extent were studied. Results: 315 of 1697 lobes (18.6%) in 156 of 299 patients (81.3%) showed PDs. Among them, 51 (3%), 257 (15.1%), and 7 (0.4%) lobes had PDs due to vascular, nonvascular, and unidentifiable causes, respectively. Vascular causes include: pulmonary arterial (PA) hypertension (0.7%), extrinsic occlusion of PA by fibrosis (0.6%), PA hypoplasia (0.6%), vasculitis (0.5%), cancer mass compressing PA, venous occlusion, AVM, and pulmonary angiosarcoma. Most of PDs were wedge-shaped and well-matched. Nonvascular causes include: mosaic attenuation (4.1%), emphysema (3.2%), interstitial fibrosis (1.6%), bronchitis (1.4%), GGO (1.2%), cellular bronchiolitis (1%), bronchiectasis, airway obstruction, compensaroty lung hyperinflation, air trapping, cor-pulmonale, bronchopneumonia, physiologic decreased ventilation, and segmental bronchial atresia. Most of PDs showed heterogeneous pattern and were not matched. Conclusions: Various vascular and nonvascular diseases cause PDs on DECTA. Each disease shows different pattern of PD depending on pathophysiology and physiologic compensation.

  12. Fourier-based linear systems description of free-breathing pulmonary magnetic resonance imaging

    Science.gov (United States)

    Capaldi, D. P. I.; Svenningsen, S.; Cunningham, I. A.; Parraga, G.

    2015-03-01

    Fourier-decomposition of free-breathing pulmonary magnetic resonance imaging (FDMRI) was recently piloted as a way to provide rapid quantitative pulmonary maps of ventilation and perfusion without the use of exogenous contrast agents. This method exploits fast pulmonary MRI acquisition of free-breathing proton (1H) pulmonary images and non-rigid registration to compensate for changes in position and shape of the thorax associated with breathing. In this way, ventilation imaging using conventional MRI systems can be undertaken but there has been no systematic evaluation of fundamental image quality measurements based on linear systems theory. We investigated the performance of free-breathing pulmonary ventilation imaging using a Fourier-based linear system description of each operation required to generate FDMRI ventilation maps. Twelve subjects with chronic obstructive pulmonary disease (COPD) or bronchiectasis underwent pulmonary function tests and MRI. Non-rigid registration was used to co-register the temporal series of pulmonary images. Pulmonary voxel intensities were aligned along a time axis and discrete Fourier transforms were performed on the periodic signal intensity pattern to generate frequency spectra. We determined the signal-to-noise ratio (SNR) of the FDMRI ventilation maps using a conventional approach (SNRC) and using the Fourier-based description (SNRF). Mean SNR was 4.7 ± 1.3 for subjects with bronchiectasis and 3.4 ± 1.8, for COPD subjects (p>.05). SNRF was significantly different than SNRC (p<.01). SNRF was approximately 50% of SNRC suggesting that the linear system model well-estimates the current approach.

  13. Regional assessment of treatment in lung cancer using lung perfusion and ventilation images

    International Nuclear Information System (INIS)

    Horikoshi, Masaki; Teshima, Takeo; Yanagimachi, Tomohiro; Ogata, Yuuko; Nukiwa, Toshihiro

    2000-01-01

    In 30 patients with lung cancer undergoing non-surgical treatment, we performed perfusion lung imaging using 99m Tc-MAA and inhalation lung studies using Technegas before and after treatment and evaluated regional perfusion and ventilation status in the lung regions where bronchogenic carcinoma was located. Regional ventilation status was preserved rather than perfusion counterpart (V>P) in 18 patients (18/30=60.0%) before treatment, while the former was better than the latter in 27 patients (27/30=90.0%) after treatment, indicating that regional ventilation status improved more significantly than regional perfusion counterpart after treatment (P=0.005). We also classified the therapeutic effect for regional perfusion and ventilation status as improved, unchanged, or worsened, respectively; improvement in regional perfusion status was observed in 17 patients (56.7%) and that in regional ventilation status in 24 patients (80.0%). There was a statistically significant correlation between improved regional perfusion and ventilation status (P=0.0018) when therapeutic effect was recognized. The patients who showed improvement in regional perfusion status after treatment always showed improved regional ventilation status, but 7 patients showed either unchanged or worsened regional perfusion status after treatment, although regional ventilation status was improved. In conclusion the pulmonary vascular beds seem more vulnerable to bronchogenic carcinoma and improvement in regional perfusion status was revealed to be more difficult than that in regional ventilation status after treatment. (author)

  14. Evaluation of imaging of the ventilatory lung motion in pulmonary diseases

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Kanai, Hisakata; Tanaka, Masao; Hirayama, Jiro; Handa, Kenjiro

    1988-01-01

    Using perfusion lung scintigram with 99m Tc-macroaggregated albumin at maximal expiration (E) and inspiration (I), images of the motion of the regional pulmonary areas and lung margins during ventilation ((E-I)/I) was obtained in patients with various respiratory diseases. The image of (E-I)/I consisted of positive and negative components. The former component visualized the motion of the regional pulmonary areas that corresponded with the ventilatory amplitude of the videodensigram. The sum of the positive component of (E-I)/I in both lungs correlated with the vital capacity (n = 50, r = 0.62). It was 163.5 ± 52.5 in cases with a vital capacity of more than 3.01, 94.1 ± 61.5 in primary lung cancer, 89.2 ± 44.7 in chronic obstructive lung diseases and 69.0 ± 27.5 in diffuse interstitial pneumonia. The distribution pattern of pulmonary perfusion and the positive component of (E-I)/I matched fairly in many cases, but did not match in some cases. The negative component of (E-I)/I demonstrated the ventilatory motion of the lung margin and its decreased activity was shown in cases with hypoventilation of various causes including pleural diseases. The sum of the negative component of (E-I)/I in the both lungs correlated with the vital capacity (n = 50, r = 0.44). These results suggest that this technique is useful to estimate the regional pulmonary ventilatioin and motion of the lung margins. (author)

  15. The multi-slice CT perfusion imaging in evaluating the prevention and treatment by edaravone on lung ischemia-reperfusion injury after pulmonary thromboembolism

    Energy Technology Data Exchange (ETDEWEB)

    Jianjun, Li; Renyou, Zhai; Dongpo, Zhang; Qiang, Huang; Dingke, Dai; Ping, Yu; Na, Bao [Department of Radiology, Beijing Chaoyang Hospital, Capital Medical Univ., Beijing (China)

    2008-10-15

    Objective: To evaluate the multi-slice CT perfusion imaging in investigating whether edaravone can prevent and treat pulmonary thromboembolism ischemia-reperfusion injury (PTE-IRI). Methods: Twenty mongrel canines were included. A Swan-Ganz catheter was introduced into the right internal jugular vein using the Seldinger technique, and then was inserted into the pulmonary artery. Balloon occlusion of the right inferior lobe pulmonary artery for 4 h was followed by removing catheter and 4 h o reperfusion. Animals were divided into four groups of A (no edaravone during ischenmia and reperfusion), B (edaravone used only during ischemia), C (edaravone used during both ischemia and reperfusion) and D group (edaravone used only during reperfusion) (n=5 per group). Every group was divided into three time points including before ischemia, 4 h after ischemia and 4 h after reperfusion. CT scan and CT perfusion were performed at the three time points. The blood flow (BF), blood volume (BV) and mean transit time (MTT) of the bilateral inferior regional lung parenchyma were measured with the software of perfusion 3. Results: CT examination showed pulmonary edema in the right inferior lung lobe at 4 h after reperfusion. (1) The BF and MTT of A, B, C and D group were[(259.4{+-}15.7)ml{center_dot}min{sup -1{center_dot}}100 g{sup -1}, (293.7{+-} 7.9) ml{center_dot}min{sup -1{center_dot}}100 g {sup -1}, (379.4{+-}14.5)ml{center_dot}min{sup -1{center_dot}}100 g{sup -1}, (382.5{+-}16.6)ml{center_dot}min{sup -1{center_dot}}. 100 g{sup -1}] and [(3.1{+-}0.2)s, (2.6{+-}0.2)s, (2.2{+-}0.1)s, (1.9{+-}0.2)s] respectively at 4 h after reperfusion. The BF and MTT were statistically different (P<0.01) between groups (A and B, A and C, A and D, B and C, B and D) except between group C and D (the P value >0.05) at 4 h after reperfusion, but the BV was not statistically different between groups (P>0.05). (2) The BF [(397.2{+-} 19.2)ml{center_dot}min{sup -1{center_dot}}100 g{sup -1} and (259

  16. Evaluation of regional pulmonary ventilation by videodensitometry using a new X-ray image processor

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Kanai, Hisakata; Handa, Kenjiro; Takizawa, Masaomi

    1988-01-01

    A new video image processing device has been produced in order to assess regional pulmonary ventilation. This device consists of a microcomputer, digital frame memory, digitizer, videomonitor, joystick and videotape recorder. The changing radiographic density of the lungs during deep respiration and forced expiration is recorded by the videotape recorder, which is connected to an image intensifier television system. This device allows the examining physician to place 6 rectangular windows of variable size over any portion of the video image using the joystick, and to measure the brightness level within these windows simultaneously. It is very characteristic that the video-densitometric curve and marks of the windows are superimposed on the frozen final frame of the sampled images. By this procedure, fair videodensigrams were obtained in various respiratory diseases, and reduction of ventilatory amplitude was shown in the hypoventilatory regions. The joint use of video-densitometry and perfusion lung scintigraphy provided helpful information concerning the regional ventilation/perfusion relationship. The videodensitometry of the lung the new X-ray image processor offers routine screening evaluation of regional pulmonary ventilation abnormalities over the entire video image of the lungs without more effort required of the patients. (author)

  17. Assessment of regional lung functional impairment with co-registered respiratory-gated ventilation/perfusion SPET-CT images: initial experiences

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Yasuhiko, Kawakami; Zaki, Mohammed; Yamashita, Tomio; Seto, Aska; Matsumoto, Tsuneo; Matsunaga, Naofumi

    2004-01-01

    In this study, respiratory-gated ventilation and perfusion single-photon emission tomography (SPET) were used to define regional functional impairment and to obtain reliable co-registration with computed tomography (CT) images in various lung diseases. Using a triple-headed SPET unit and a physiological synchroniser, gated perfusion SPET was performed in a total of 78 patients with different pulmonary diseases, including metastatic nodules (n=15); in 34 of these patients, it was performed in combination with gated technetium-99m Technegas SPET. Projection data were acquired using 60 stops over 120 for each detector. Gated end-inspiration and ungated images were reconstructed from 1/8 data centered at peak inspiration for each regular respiratory cycle and full respiratory cycle data, respectively. Gated images were registered with tidal inspiration CT images using automated three-dimensional (3D) registration software. Registration mismatch was assessed by measuring 3D distance of the centroid of the nine selected round perfusion-defective nodules. Gated SPET images were completed within 29 min, and increased the number of visible ventilation and perfusion defects by 9.7% and 17.2%, respectively, as compared with ungated images; furthermore, lesion-to-normal lung contrast was significantly higher on gated SPET images. In the nine round perfusion-defective nodules, gated images yielded a significantly better SPET-CT match compared with ungated images (4.9±3.1 mm vs 19.0±9.1 mm, P<0.001). The co-registered SPET-CT images allowed accurate perception of the location and extent of each ventilation/perfusion defect on the underlying CT anatomy, and characterised the pathophysiology of the various diseases. By reducing respiratory motion effects and enhancing perfusion/ventilation defect clarity, gated SPET can provide reliable co-registered images with CT images to accurately characterise regional functional impairment in various lung diseases. (orig.)

  18. Radioaerosol inhalation lung imaging for the diagnosis of chronic obstructive pulmonary diseases in Thailand. Final report for the period 10 December 1987 - 15 December 1993

    Energy Technology Data Exchange (ETDEWEB)

    Buachum, V [Chulalongkorn Univ., Bangkok (Thailand). Nuclear Medicine Div.

    1993-12-01

    The radionuclide pulmonary function studies such as aerosol inhalation lung imaging, mucociliary clearance and pulmonary epithelial were developed and studied in normal and chronic obstructive pulmonary disease. The results of the aerosol inhalation lung imaging in 71 cases of COPD revealed that the aerosol inhalation lung scan was the most sensitive test for the diagnosis of early COPD as compared to the chest X-ray, vascular perfusion lung scan and spirometric test (% FEVI). The aerosol and perfusion lung scan were also performed in 21 cases of carcinoma of lung who had been treated with external radiation or chemotherapy. The result of study revealed 5 patients died during treatment, 5 patients were slightly improved, no significant change was detected in 10 cases and deterioration was found in one patient. The lung scintigraphy was studied in 15 cases of well differentiated carcinoma of thyroid with pulmonary metastasis who had I-131 treatment. The study showed that the radioactive iodine treatment dose had minimal effect on the post treatment lung imaging study. The perfusion and aerosol study in 15 cases of operated patients revealed no evidence of pulmonary embolism in post operative study. Abnormal vascular disease or pulmonary embolism was observed in one patient preoperatively. 12 refs, 13 figs, 13 tabs.

  19. Radioaerosol inhalation lung imaging for the diagnosis of chronic obstructive pulmonary diseases in Thailand. Final report for the period 10 December 1987 - 15 December 1993

    International Nuclear Information System (INIS)

    Buachum, V.

    1993-12-01

    The radionuclide pulmonary function studies such as aerosol inhalation lung imaging, mucociliary clearance and pulmonary epithelial were developed and studied in normal and chronic obstructive pulmonary disease. The results of the aerosol inhalation lung imaging in 71 cases of COPD revealed that the aerosol inhalation lung scan was the most sensitive test for the diagnosis of early COPD as compared to the chest X-ray, vascular perfusion lung scan and spirometric test (% FEVI). The aerosol and perfusion lung scan were also performed in 21 cases of carcinoma of lung who had been treated with external radiation or chemotherapy. The result of study revealed 5 patients died during treatment, 5 patients were slightly improved, no significant change was detected in 10 cases and deterioration was found in one patient. The lung scintigraphy was studied in 15 cases of well differentiated carcinoma of thyroid with pulmonary metastasis who had I-131 treatment. The study showed that the radioactive iodine treatment dose had minimal effect on the post treatment lung imaging study. The perfusion and aerosol study in 15 cases of operated patients revealed no evidence of pulmonary embolism in post operative study. Abnormal vascular disease or pulmonary embolism was observed in one patient preoperatively. 12 refs, 13 figs, 13 tabs

  20. Ventilation-perfusion scans in neonatal regional pulmonary emphysema complicating ventilatory assistance

    International Nuclear Information System (INIS)

    Leonidas, J.C.; Moylan, F.M.B.; Kahn, P.C.; Ramenofsky, M.L.

    1978-01-01

    Two cases of ventilator-related neonatal lobar overexpansion with similar radiographic appearance, but probably different pathogenesis, are presented. In one infant, persistent interstitial lobar emphysema was confirmed by markedly decreased perfusion shown on scintigraphy; this information was of great value in predicting the beneficial effect of lobectomy. In the other case, ventilation and perfusion scans indicated functional value of the emphysematous lobe and correctly suggested conservative management. Radioisotope lung scans may provide valuable information regarding lung function in regional pulmonary emphysema associated with assisted ventilation in neonatal respiratory distress syndrome, and thus determine patient management

  1. Brain Perfusion SPECT Imaging in Sturge - Weber Syndrome : Comparison with MR Imaging

    International Nuclear Information System (INIS)

    Ryu, Jin Sook; Choi, Yun Young; Moon, Dae Hyuk; Yang, Seoung Oh; Ko, Tae Sung; Yoo, Shi Joon; Lee, Hee Kyung

    1996-01-01

    The purpose of this study was evaluate the characteristic perfusion changes in patients with Sturge-Weber syndrome by comparison of the findings of brain MR images and perfusion SPECT images. 99m Tc-HMPAO or 99m Tc-ECD interictal brain SPECTs were performed on 5 pediatric patients with Struge-Weber syndrome within 2 weeks after MR imaging. Brain SPECTs of three patients without calcification showed diminished perfusion in the affected area on MR image. A 3 month-old patient without brain atrophy or calcification demonstrated paradoxical hyperperfusion in the affected hemisphere, and follow-up perfusion SPECT revealed decreased perfusion in the same area. The other patient with advanced calcified lesion and atrophy on MR image showed diffusely decreased perfusion in the affected hemisphere, but a focal area of increased perfusion was also noted in the ipsilateral temporal lobe on SPECT. In conclusion, brain perfusion of the affected area of Sturge-Weber syndrome patients was usually diminished, but early or advanced patients may show paradoxical diffuse or focal hyperperfusion in the affected hemisphere. Further studies are needed for better understanding of these perfusion changes and pathophysiology of Struge-Weber syndrome.

  2. Distinguishing Chronic Thromboembolic Pulmonary Hypertension From Other Causes of Pulmonary Hypertension Using CT.

    Science.gov (United States)

    Grosse, Alexandra; Grosse, Claudia; Lang, Irene M

    2017-12-01

    The purpose of this study was to discern imaging findings that separate chronic thromboembolic pulmonary hypertension (CTEPH) from other causes of pulmonary hypertension (PH). A total of 143 patients with proven PH (group 1, pulmonary arterial hypertension; group 2, PH due to left heart disease; group 3, PH due to lung disease; group 4, CTEPH; and group 5, PH due to unclear or multifactorial mechanisms) underwent MDCT angiography. The CT images were assessed for the presence of chronic pulmonary embolism (PE), disparity in segmental vessel size, mosaic perfusion, parenchymal densities, bronchial dilatation, and collateral arteries. The frequencies of vascular signs of chronic PE, disparity in segmental vessel size, mosaic perfusion, parenchymal densities, bronchial collateral arteries, and bronchial dilatation were statistically significantly higher in patients with CTEPH than in patients with nonthromboembolic PH. Vascular signs of chronic PE, mosaic perfusion, parenchymal densities, and bronchial dilatation without bronchial wall thickening were significantly more frequent in patients with CTEPH than in patients in groups 1, 2, 3, and 5. There was no significant difference in the frequencies of bronchial collateral arteries between patients with CTEPH and patients in groups 3 and 5. Most patients with CTEPH have direct vascular signs of chronic PE. Secondary signs include disparity in segmental vessel size, mosaic perfusion pattern, parenchymal densities, collateral bronchial arteries, and bronchial dilatation, which help distinguish CTEPH from other causes of PH.

  3. Meta-Analysis of Stress Myocardial Perfusion Imaging

    Science.gov (United States)

    2017-06-06

    Coronary Disease; Echocardiography; Fractional Flow Reserve, Myocardial; Hemodynamics; Humans; Magnetic Resonance Imaging; Myocardial Perfusion Imaging; Perfusion; Predictive Value of Tests; Single Photon Emission Computed Tomography; Positron Emission Tomography; Multidetector Computed Tomography; Echocardiography, Stress; Coronary Angiography

  4. Isolated Left Pulmonary Artery Agenesis: A Case Report

    Directory of Open Access Journals (Sweden)

    Tansel Ansal Balcı

    2012-08-01

    Full Text Available Unilateral pulmonary artery agenesis without any cardiovascular malformation is a rare anomaly. We present the imaging findings of a patient who was diagnosed as isolated left pulmonary artery agenesis. A 27-year-old female patient was admitted to our hospital due to dyspnea during exercise for five years. Chest X-ray revealed minimally small left pulmonary hilum and left lung. She was admitted to our clinic with the suspicion of pulmonary artery pathology. Absent perfusion of the left lung with normal ventilation was visualized on scintigraphy. MDCT angiography of pulmonary arteries showed absent left main pulmonary artery with systemic collaterals around left hemithorax. Pulmonary artery agenesis can be asymptomatic and isolated until adulthood. Both scintigraphy and CT angiography images of pulmonary artery agenesis of a patient are rare in the literature. Pulmonary ventilation- perfusion scintigraphy can be used not only for pulmonary embolism but also pathologies involving pulmonary artery and its branches. (MIRT 2012;21:80-83

  5. Evaluation of peripheral pulmonary perfusion decrease of 99m-Tc MAA scintigraphy using SPECT/CT

    International Nuclear Information System (INIS)

    Yoneyama, Tatsuya; Kamisaki, Yuichi; Kameda, Keisuke; Seto, Hikaru

    2012-01-01

    We often experienced non-segmented peripheral patchy decrease (NSPPD) in 99m Tc-macro-aggregated albumin (MAA) pulmonary perfusion scan using single photon emission computed tomography (SPECT)/CT. Seventy cases were evaluated by 99m Tc-MAA SPECT/CT. NSPPD was seen in 22 cases (31.4%), of which 17 were assessed for pulmonary hypertension. Pulmonary hypertension was diagnosed in 11 cases, which consisted of 3 chronic thromboembolic pulmonary hypertension, 2 idiopathic pulmonary arterial hypertension, 2 systemic lupus eryhthematosus and 4 left ventricular heart disease. We suggest that NSPPD may indicate the early stage of pulmonary hypertension (PH). (author)

  6. Perfusion-weighted MR imaging of uterine leiomyoma

    Energy Technology Data Exchange (ETDEWEB)

    Takase, Hiroyasu; Munechika, Hirotsugu [Showa Univ., Tokyo (Japan). School of Medicine

    2001-06-01

    Serial images of uterine leiomyoma in gradient-echo, echo-planar, magnetic resonance imaging were taken to draw a {delta}R2{sup *} curve after intravenous bolus injection of Gd-DTPA. The {delta}R2{sup *} integral was calculated from a {delta}R2{sup *} curve to have relative perfusion of uterine leiomyoma. We then, evaluated the amount of perfusion correlated with MR findings, size and number of leiomyoma or the clinical symptoms and established that perfusion was correlated positively with the findings of T2 weighted images and clinical symptoms but not with other MR findings or size and number of leiomyoma. In conclusion, we presumed that the clinical symptoms could be reduced by decreasing of an amount of perfusion of uterine leiomyoma in some means. However, it remained uncertain why severe clinical symptoms were associated with a high amount of perfusion in uterine leiomyomas. (author)

  7. Estimation of pulmonary hypertension in lung and valvular heart diseases by perfusion lung scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Tadashige [Shinshu Univ., Matsumoto, Nagano (Japan). School of Allied Medical Sciences; Tanaka, Masao; Yazaki, Yoshikazu; Kitabayashi, Hirosi; Koizumi, Tomonori; Kubo, Keisi; Sekiguchi, Morie; Yano, Kesato

    1999-06-01

    To estimate pulmonary hypertension, we measured postural differences in pulmonary blood flow for the lateral decubitus positions on perfusion lung scintigrams with Tc-99 m macro-aggregated albumin, applying the method devised by Tanaka et al (Eur J Nucl Med 17: 320-326, 1990). Utilizing a scintillation camera coupled to a minicomputer system, changes in the distribution of pulmonary blood flow caused by gravitational effects, namely, changes in the total count ratios for the right lung versus the left lung in the right and left lateral decubitus positions (R/L), were obtained for 44 patients with lung disease, 95 patients with valvular heart disease, and 23 normal subjects. Mean standard deviation in the R/L ratios was 3.09{+-}1.28 for the normal subjects, 1.97{+-}0.89 for the patients with lung disease, and 1.59{+-}0.59 for the patients with valvular heart disease. The R/L ratios correlated with mean pulmonary arterial pressure and cardio-thoracic ratios in the lung disease and valvular heart disease groups, with pulmonary arteriolar resistance in the former, and with pulmonary capillary wedge pressure in the latter. Defining pulmonary hypertension (>20 mmHg) as an R/L ratio of less than 1.81, which is the mean-1 standard deviation for normal subjects, the sensitivity and the specificity of the R/L ratio for the diagnosis of pulmonary hypertension were 62.9% and 76.2%, respectively, for the lung disease patients, and 80.3% and 61.8%, respectively, for the valvular heart disease patients. This method seems to be useful for the pathophysiologic evaluation of pulmonary perfusion in cases of lung disease and valvular heart disease. (author)

  8. Estimation of pulmonary hypertension in lung and valvular heart diseases by perfusion lung scintigraphy

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Yazaki, Yoshikazu; Kitabayashi, Hirosi; Koizumi, Tomonori; Kubo, Keisi; Sekiguchi, Morie; Yano, Kesato

    1999-01-01

    To estimate pulmonary hypertension, we measured postural differences in pulmonary blood flow for the lateral decubitus positions on perfusion lung scintigrams with Tc-99 m macro-aggregated albumin, applying the method devised by Tanaka et al (Eur J Nucl Med 17: 320-326, 1990). Utilizing a scintillation camera coupled to a minicomputer system, changes in the distribution of pulmonary blood flow caused by gravitational effects, namely, changes in the total count ratios for the right lung versus the left lung in the right and left lateral decubitus positions (R/L), were obtained for 44 patients with lung disease, 95 patients with valvular heart disease, and 23 normal subjects. Mean standard deviation in the R/L ratios was 3.09±1.28 for the normal subjects, 1.97±0.89 for the patients with lung disease, and 1.59±0.59 for the patients with valvular heart disease. The R/L ratios correlated with mean pulmonary arterial pressure and cardio-thoracic ratios in the lung disease and valvular heart disease groups, with pulmonary arteriolar resistance in the former, and with pulmonary capillary wedge pressure in the latter. Defining pulmonary hypertension (>20 mmHg) as an R/L ratio of less than 1.81, which is the mean-1 standard deviation for normal subjects, the sensitivity and the specificity of the R/L ratio for the diagnosis of pulmonary hypertension were 62.9% and 76.2%, respectively, for the lung disease patients, and 80.3% and 61.8%, respectively, for the valvular heart disease patients. This method seems to be useful for the pathophysiologic evaluation of pulmonary perfusion in cases of lung disease and valvular heart disease. (author)

  9. Computerized analysis of brain perfusion parameter images

    International Nuclear Information System (INIS)

    Turowski, B.; Haenggi, D.; Wittsack, H.J.; Beck, A.; Aurich, V.

    2007-01-01

    Purpose: The development of a computerized method which allows a direct quantitative comparison of perfusion parameters. The display should allow a clear direct comparison of brain perfusion parameters in different vascular territories and over the course of time. The analysis is intended to be the basis for further evaluation of cerebral vasospasm after subarachnoid hemorrhage (SAH). The method should permit early diagnosis of cerebral vasospasm. Materials and Methods: The Angiotux 2D-ECCET software was developed with a close cooperation between computer scientists and clinicians. Starting from parameter images of brain perfusion, the cortex was marked, segmented and assigned to definite vascular territories. The underlying values were averages for each segment and were displayed in a graph. If a follow-up was available, the mean values of the perfusion parameters were displayed in relation to time. The method was developed under consideration of CT perfusion values but is applicable for other methods of perfusion imaging. Results: Computerized analysis of brain perfusion parameter images allows an immediate comparison of these parameters and follow-up of mean values in a clear and concise manner. Values are related to definite vascular territories. The tabular output facilitates further statistic evaluations. The computerized analysis is precisely reproducible, i. e., repetitions result in exactly the same output. (orig.)

  10. Topographic distribution of pulmonary ventilation and perfusion in the horse

    International Nuclear Information System (INIS)

    Amis, T.C.; Pascoe, J.R.; Hornof, W.

    1984-01-01

    The regional distribution of ventilation to perfusion ratios (VA/Q) in the lungs of 8 healthy standing Thoroughbred geldings (4.4 +/- 1.5 years, 465.7 +/- 46.6 kg) was studied, using steady-state inhalation and IV infusion of the radioactive gas krypton-81m. The VA/Q was uniformly distributed within a vertical lung strip centered over the 9th rib on the right side. Ventilation per unit of alveolar volume (V/VA) assessed from the clearance of inhaled radioactive gas in 5 horses increased from 0.49 +/- 0.13 (arbitrary units) in nondependent lung zones to 1.45 +/- 0.16 in dependent lung zones. Seemingly, a vertical gradient of pulmonary ventilation exists in the horse that is matched by a similar gradient of perfusion

  11. Topographic distribution of pulmonary ventilation and perfusion in the horse

    Energy Technology Data Exchange (ETDEWEB)

    Amis, T.C.; Pascoe, J.R.; Hornof, W.

    1984-08-01

    The regional distribution of ventilation to perfusion ratios (VA/Q) in the lungs of 8 healthy standing Thoroughbred geldings (4.4 +/- 1.5 years, 465.7 +/- 46.6 kg) was studied, using steady-state inhalation and IV infusion of the radioactive gas krypton-81m. The VA/Q was uniformly distributed within a vertical lung strip centered over the 9th rib on the right side. Ventilation per unit of alveolar volume (V/VA) assessed from the clearance of inhaled radioactive gas in 5 horses increased from 0.49 +/- 0.13 (arbitrary units) in nondependent lung zones to 1.45 +/- 0.16 in dependent lung zones. Seemingly, a vertical gradient of pulmonary ventilation exists in the horse that is matched by a similar gradient of perfusion.

  12. Imaging Human Brain Perfusion with Inhaled Hyperpolarized 129Xe MR Imaging.

    Science.gov (United States)

    Rao, Madhwesha R; Stewart, Neil J; Griffiths, Paul D; Norquay, Graham; Wild, Jim M

    2018-02-01

    Purpose To evaluate the feasibility of directly imaging perfusion of human brain tissue by using magnetic resonance (MR) imaging with inhaled hyperpolarized xenon 129 ( 129 Xe). Materials and Methods In vivo imaging with 129 Xe was performed in three healthy participants. The combination of a high-yield spin-exchange optical pumping 129 Xe polarizer, custom-built radiofrequency coils, and an optimized gradient-echo MR imaging protocol was used to achieve signal sensitivity sufficient to directly image hyperpolarized 129 Xe dissolved in the human brain. Conventional T1-weighted proton (hydrogen 1 [ 1 H]) images and perfusion images by using arterial spin labeling were obtained for comparison. Results Images of 129 Xe uptake were obtained with a signal-to-noise ratio of 31 ± 9 and demonstrated structural similarities to the gray matter distribution on conventional T1-weighted 1 H images and to perfusion images from arterial spin labeling. Conclusion Hyperpolarized 129 Xe MR imaging is an injection-free means of imaging the perfusion of cerebral tissue. The proposed method images the uptake of inhaled xenon gas to the extravascular brain tissue compartment across the intact blood-brain barrier. This level of sensitivity is not readily available with contemporary MR imaging methods. © RSNA, 2017.

  13. Intra-Arterial MR Perfusion Imaging of Meningiomas: Comparison to Digital Subtraction Angiography and Intravenous MR Perfusion Imaging.

    Directory of Open Access Journals (Sweden)

    Mark A Lum

    Full Text Available To evaluate the ability of IA MR perfusion to characterize meningioma blood supply.Studies were performed in a suite comprised of an x-ray angiography unit and 1.5T MR scanner that permitted intraprocedural patient movement between the imaging modalities. Patients underwent intra-arterial (IA and intravenous (IV T2* dynamic susceptibility MR perfusion immediately prior to meningioma embolization. Regional tumor arterial supply was characterized by digital subtraction angiography and classified as external carotid artery (ECA dural, internal carotid artery (ICA dural, or pial. MR perfusion data regions of interest (ROIs were analyzed in regions with different vascular supply to extract peak height, full-width at half-maximum (FWHM, relative cerebral blood flow (rCBF, relative cerebral blood volume (rCBV, and mean transit time (MTT. Linear mixed modeling was used to identify perfusion curve parameter differences for each ROI for IA and IV MR imaging techniques. IA vs. IV perfusion parameters were also directly compared for each ROI using linear mixed modeling.18 ROIs were analyzed in 12 patients. Arterial supply was identified as ECA dural (n = 11, ICA dural (n = 4, or pial (n = 3. FWHM, rCBV, and rCBF showed statistically significant differences between ROIs for IA MR perfusion. Peak Height and FWHM showed statistically significant differences between ROIs for IV MR perfusion. RCBV and MTT were significantly lower for IA perfusion in the Dural ECA compared to IV perfusion. Relative CBF in IA MR was found to be significantly higher in the Dural ICA region and MTT significantly lower compared to IV perfusion.

  14. The diagnostic value of ventilation-perfusion scintigraphy combined with plasma D-dimer assay in diagnosis of pulmonary embolism

    International Nuclear Information System (INIS)

    Wang Qian; Huang Lili; Qin Shuling; Yue Minggang; Wang Yu; Nie Yuxin; Liang Tiejun

    2005-01-01

    Objective: To investigate the clinical diagnostic value of ventilation-perfusion scintigraphy combined with plasma D-dimer assay in diagnosis of pulmonary embolism (PE). Methods: One hundred and four patients with clinically suspected PE underwent both pulmonary ventilation-perfusion scintigraphy and plasma D-dimer assay. According to the criteria of prospective investigation of the pulmonary embolism diagnosis (PIOPED), ventilation-perfusion scintigraphy was interpreted as normal, very low or low probability of PE, intermediate probability of PE and high probability of PE. High probability was considered as positive; normal and very low or low probability as negative and intermediate probability as non-diagnostic. Plasma D-dimer levels were measured using a quantitative immunoturbidimetric method, and a cut-off value of 500 mg/L was used in the diagnosis of PE. Clinical diagnostic value of ventilation-perfusion scintigraphy, D-dimer assay and combined use of ventilation-perfusion scintigraphy and D-dimer assay for diagnosing PE was evaluated, respectively, comparing with the final clinical diagnosis that was based on the clinical findings. Results: Among the 104 patients, 44 were diagnosed with PE and 60 were excluded. Ventilation-perfusion scintigraphy provided diagnostic interpretations for 86 (82.7%) patients, and non-diagnostic interpretations for 18 (17.3%) patients. For diagnosing PE, the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of ventilation-perfusion scintigraphy was 84.1%, 75.0%, 78.8%, 71.2% and 86.5%, respectively, and with D-dimer assay was 93.2%, 60.0%, 74.0%, 63.1% and 92.3%, respectively. If a plasma D-dimer level of < 500 mg/L was taken as a criterion to exclude PE for those intermediate probability of ventilation-perfusion scintigraphy, the diagnostic specificity and accuracy would be raised to 85.0% and 84.6%, respectively. Conclusions: When a non-diagnostic interpretation was occurred on

  15. Reverse ventilation--perfusion mismatch

    International Nuclear Information System (INIS)

    Palmaz, J.C.; Barnett, C.A.; Reich, S.B.; Krumpe, P.E.; Farrer, P.A.

    1984-01-01

    Patients having lobar airway obstruction or consolidation usually have decreases of both ventilation and perfusion on lung scans. We report three patients in whom hypoxic vasoconstriction was apparently incomplete, resulting in a ''reversed'' ventilation-perfusion mismatch. Perfusion of the hypoxic lobe on the radionuclide scan was associated with metabolic alkalosis, pulmonary venous and pulmonary arterial hypertension in these patients

  16. Magnetic resonance cardiac perfusion imaging-a clinical perspective

    International Nuclear Information System (INIS)

    Hunold, Peter; Schlosser, Thomas; Barkhausen, Joerg

    2006-01-01

    Coronary artery disease (CAD) with its clinical appearance of stable or unstable angina and acute myocardial infarction is the leading cause of death in developed countries. In view of increasing costs and the rising number of CAD patients, there has been a major interest in reliable non-invasive imaging techniques to identify CAD in an early (i.e. asymptomatic) stage. Since myocardial perfusion deficits appear very early in the ''ischemic cascade'', a major breakthrough would be the non-invasive quantification of myocardial perfusion before functional impairment might be detected. Therefore, there is growing interest in other, target-organ-specific parameters, such as relative and absolute myocardial perfusion imaging. Magnetic resonance (MR) imaging has been proven to offer attractive concepts in this respect. However, some important difficulties have not been resolved so far, which still causes uncertainty and prevents the broad application of MR perfusion imaging in a clinical setting. This review explores recent technical developments in MR hardware, software and contrast agents, as well as their impact on the current and future clinical status of MR imaging of first-pass myocardial perfusion imaging. (orig.)

  17. Magnetic resonance cardiac perfusion imaging-a clinical perspective

    Energy Technology Data Exchange (ETDEWEB)

    Hunold, Peter; Schlosser, Thomas; Barkhausen, Joerg [University Hospital, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany)

    2006-08-15

    Coronary artery disease (CAD) with its clinical appearance of stable or unstable angina and acute myocardial infarction is the leading cause of death in developed countries. In view of increasing costs and the rising number of CAD patients, there has been a major interest in reliable non-invasive imaging techniques to identify CAD in an early (i.e. asymptomatic) stage. Since myocardial perfusion deficits appear very early in the ''ischemic cascade'', a major breakthrough would be the non-invasive quantification of myocardial perfusion before functional impairment might be detected. Therefore, there is growing interest in other, target-organ-specific parameters, such as relative and absolute myocardial perfusion imaging. Magnetic resonance (MR) imaging has been proven to offer attractive concepts in this respect. However, some important difficulties have not been resolved so far, which still causes uncertainty and prevents the broad application of MR perfusion imaging in a clinical setting. This review explores recent technical developments in MR hardware, software and contrast agents, as well as their impact on the current and future clinical status of MR imaging of first-pass myocardial perfusion imaging. (orig.)

  18. Role of perfusion SPECT in prediction and measurement of pulmonary complications after radiotherapy for lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Farr, Katherina P.; Khalil, Azza A.; Grau, Cai [Aarhus University Hospital, Department of Oncology, Aarhus C (Denmark); Kramer, Stine; Morsing, Anni [Aarhus University Hospital, Department of Nuclear Medicine and PET Centre, Aarhus C (Denmark)

    2015-07-15

    The purpose of the study was to evaluate the ability of baseline perfusion defect score (DS) on SPECT to predict the development of severe symptomatic radiation pneumonitis (RP) and to evaluate changes in perfusion on SPECT as a method of lung perfusion function assessment after curative radiotherapy (RT) for non-small-cell lung cancer (NSCLC). Patients with NSCLC undergoing curative RT were included prospectively. Perfusion SPECT/CT and global pulmonary function tests (PFT) were performed before RT and four times during follow-up. Functional activity on SPECT was measured using a semiquantitative perfusion DS. Pulmonary morbidity was graded by the National Cancer Institute's Common Terminology Criteria for Adverse Events version 4 for pneumonitis. Patients were divided into two groups according to the severity of RP. A total of 71 consecutive patients were included in the study. Baseline DS was associated with chronic obstructive pulmonary disease. A significant inverse correlation was found between baseline DS and forced expiratory volume in 1 s and diffusing capacity of the lung for carbon monoxide. Patients with severe RP had significantly higher baseline total lung DS (mean 5.43) than those with no or mild symptoms (mean DS 3.96, p < 0.01). PFT results were not different between these two groups. The odds ratio for total lung DS was 7.8 (95 % CI 1.9 - 31) demonstrating the ability of this parameter to predict severe RP. Adjustment for other potential confounders known to be associated with increased risk of RP was performed and did not change the odds ratio. The median follow-up time after RT was 8.4 months. The largest DS increase of 13.3 % was associated with severe RP at 3 months of follow-up (p < 0.01). The development of severe RP during follow-up was not associated with changes in PFT results. Perfusion SPECT is a valuable method for predicting severe RP and for assessing changes in regional functional perfusion after curative RT comparable with

  19. Clinical studies on myocardial perfusion imaging in patients with right ventricular overload

    International Nuclear Information System (INIS)

    Abo, Kenji; Yamagata, Takashi; Nakajima, Masao; Fujita, Kimiaki; Morita, Nobuo

    1979-01-01

    Patients with heart disease which had been clinically diagnosed underwent 201 Tl myocardial perfusion imaging. The thickness of right ventricular wall measured from original images was directly proportional to systolic pressure of the right ventricle measured by cardiac catheterization, and 201 Tl activity in the right ventricle was more directly proportional to systolic pressure of the right ventricle. Imaging patterns of various diseases were also described. Images of patients with hypertrophic cardiomyopathy revealed that right ventricular wall was thin and right ventricular cavity was small, but the thickness of septal wall and left ventricular wall were maximal. Images of patients with mitral insufficiency revealed that the thickness of right ventricular wall, septal wall, and left ventricular wall was medium, and the right ventricular cavity was smaller than the left ventricular cavity. Images of patients with congestive cardiomyopathy and congestive cardiac failure showed that enlargement of both ventricular cavities was disproportionate to the thickness of each wall. Images of patients with arterial septal defect revealed that the thickness of each wall was comparatively normal, the right ventricular cavity was maximal, and the left ventricular cavity was minimal. Images of patients with primary pulmonary hypertention, pulmonary stenosis and tetralogy of Fallot in whom pressure overload was recognized revealed severe thickenings of right ventricular wall, moderate enlargement of the right ventricle, small left ventricle, and thin left ventricular wall. (Tsunoda, M.)

  20. Unilateral absence of lung perfusion resulting from endarteritis of the pulmonary artery

    International Nuclear Information System (INIS)

    Calegaro, J.U.M.; Turini, T.L.

    This case shows endarteritis of left pulmonary artery in the angiographic study with absent perfusion of the left lung in the MAA 131 I scintigraphy. Considerations are made conderning the presumable diagnosis of infection by 'toxocara canis' larval form. The literature review don't point out a similar case. (author) [pt

  1. A new application of Bull's eye analysis to lung perfusion scintigraphy

    International Nuclear Information System (INIS)

    Yasui, Kotaro; Kohno, Yoshihiro; Akaki, Shiro; Hasegawa, Mari; Nakagawa, Tomio; Simizu, Mitsuharu; Takeda, Yoshihiro; Hiraki, Yoshio; Nagaya, Isao.

    1990-01-01

    Technetium-99m macroaggregated albumin lung perfusion scintigraphy was performed and evaluated semiquantitatively by Bull's eye analysis in 24, including 7 with central pulmonary carcinoma, 3 with hypersensitivity pneumonitis (HP), 3 with diffuse panbronchiolitis (DPB) and 11 normal subjects. First, whole lung field was divided into three regions by three concentric circles. And then radial axes were projected from the center to define 36 sectors, 10 degree each. The counts of each sector was calculated and Bull's eye image and circumferential profile curve were displayed. The patient's map was compared with the lower limit of normal (mean-2 SD), and the extent score (ES) and the severity score (SS) were calculated. The ES was 0.25±0.12 in pulmonary carcinoma (n=7), 0.08±0.07 in HP (n=3), 0.06±0.04 in DPB (n=3). The SS was 26.39±15.17 in pulmonary carcinoma, 4.75±5.57 in HP, 4.29±3.67 in DPB. In one case of central pulmonary carcinoma, segmental perfusion defect was evaluated semiquantitatively by Bull's eye image and circumferential profile curve. And in one case of HP, the change of regional pulmonary blood flow could be followed easily using extent and severity map. This new application of Bull's eye analysis to lung perfusion scintigraphy might be useful to evaluate regional pulmonary blood flow. (author)

  2. Emergency perfusion lung scan of pulmonary embolism

    International Nuclear Information System (INIS)

    Ueno, Kyoichi; Kabuto, Hiroko; Rikimaru, Shigeho

    1984-01-01

    Pulmonary embolism (PE) has been reported to be quite rare in Japan, and there have been few clinical studies on the nuclear diagnosis of PE with the exception of several case reports. However, we have experienced 12 acute PE, and 2 chronic PE in 5 years 2 months. In 33 emergency cases who were highly suspected to have PE, we could diagnose 12 cases of PE, and 19 cases of non-PE. However, the remaining 2 cases were equivocal because of underlying chronic lung disease. Using Kr-81m ventilation lung scan, V/Q mismatch was found in all of 10 cases. Usefulness of emergency perfusion lung scan in Japan should be stressed. (author)

  3. Imaging of ventilation/perfusion ratio by gated regional spirometry

    International Nuclear Information System (INIS)

    Touya, J.J.; Jones, J.P.; Price, R.R.; Patton, J.A.; Erickson, J.J.; Rollo, F.D.

    1981-01-01

    Gated 133 Xe images of patients rebreathing into a closed system can provide images of the distribution of lung volumes, ventilation and specific ventilation. These have been shown to be accurate, precise, and do not require unusually sophisticated equipment or skills. A mathematical transformation is used to correct the images for lung movement, which does not alter the total number of counts in the image. Perfusion images are gated to remove motion blurring but not transformed. Ventilation/perfusion images showing the distribution of V/Q ratio are then generated from the individual ventilation and perfusion images. (author)

  4. Ventilation/perfusion SPECT/CT in patients with pulmonary emphysema. Evaluation of software-based analysing.

    Science.gov (United States)

    Schreiter, V; Steffen, I; Huebner, H; Bredow, J; Heimann, U; Kroencke, T J; Poellinger, A; Doellinger, F; Buchert, R; Hamm, B; Brenner, W; Schreiter, N F

    2015-01-01

    The purpose of this study was to evaluate the reproducibility of a new software based analysing system for ventilation/perfusion single-photon emission computed tomography/computed tomography (V/P SPECT/CT) in patients with pulmonary emphysema and to compare it to the visual interpretation. 19 patients (mean age: 68.1 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. Data were analysed by two independent observers in visual interpretation (VI) and by software based analysis system (SBAS). SBAS PMOD version 3.4 (Technologies Ltd, Zurich, Switzerland) was used to assess counts and volume per lung lobe/per lung and to calculate the count density per lung, lobe ratio of counts and ratio of count density. VI was performed using a visual scale to assess the mean counts per lung lobe. Interobserver variability and association for SBAS and VI were analysed using Spearman's rho correlation coefficient. Interobserver agreement correlated highly in perfusion (rho: 0.982, 0.957, 0.90, 0.979) and ventilation (rho: 0.972, 0.924, 0.941, 0.936) for count/count density per lobe and ratio of counts/count density in SBAS. Interobserver agreement correlated clearly for perfusion (rho: 0.655) and weakly for ventilation (rho: 0.458) in VI. SBAS provides more reproducible measures than VI for the relative tracer uptake in V/P SPECT/CTs in patients with pulmonary emphysema. However, SBAS has to be improved for routine clinical use.

  5. Study on incidence of pulmonary embolism in patients with cardiac pacemakers using lung perfusion mapping and ventilation scanning

    International Nuclear Information System (INIS)

    Yamashina, Hideki; Higo, Masanori; Sueda, Takashi

    1990-01-01

    We investigated pulmonary perfusion mapping and ventilation scanning employing 99mTC-MMA and 81mKr-Gas in patients with DDD and VVI cardiac pacemaker implantation. In 51 cases among 175 patients we observed some defects which matched the results from lung perfusion scanning in the pulmonary segments and sub-segments. These were diagnosed as pulmonary embolism after the possibility of other pulmonary diseases was rejected. The incidence rate of pulmonary embolism in patients with VVI (Ventricular pacing/sensing, inhibited type) pacemakers was 47 out of 138, or 34.1%, especially for those who received a pulmonary scanning examination whithin 6 months after pacemaker implantation. In contrast, those who were examined after 6 months had lower rates as well as chronological factors. The incidence rate of pulmonary embolism in 37 patients with DDD (Double chamber pacing/sensing, double modes of response) pacemakers was 10.8%, considerably lower than that for patients with VVI pacemakers. Therefore, one main factor of pulmonary embolism in patients with pacemakers could be the non-physiological phase of the contractions of both atria and ventricles. Other factors, such as the presence of foreign bodies in the endocardium, aging, and hypertension, could also promote pulmonary embolism. (author)

  6. Role of ventilation scintigraphy in diagnosis of acute pulmonary embolism: an evaluation using artificial neural networks

    International Nuclear Information System (INIS)

    Evander, Eva; Holst, Holger; Jaerund, Andreas; Wollmer, Per; Edenbrandt, Lars; Ohlsson, Mattias; Aastroem, Karl

    2003-01-01

    The purpose of this study was to assess the value of the ventilation study in the diagnosis of acute pulmonary embolism using a new automated method. Either perfusion scintigrams alone or two different combinations of ventilation/perfusion scintigrams were used as the only source of information regarding pulmonary embolism. A completely automated method based on computerised image processing and artificial neural networks was used for the interpretation. Three artificial neural networks were trained for the diagnosis of pulmonary embolism. Each network was trained with 18 automatically obtained features. Three different sets of features originating from three sets of scintigrams were used. One network was trained using features obtained from each set of perfusion scintigrams, including six projections. The second network was trained using features from each set of (joint) ventilation and perfusion studies in six projections. A third network was trained using features from the perfusion study in six projections combined with a single ventilation image from the posterior view. A total of 1,087 scintigrams from patients with suspected pulmonary embolism were used for network training. The test group consisted of 102 patients who had undergone both scintigraphy and pulmonary angiography. Performances in the test group were measured as area under the receiver operation characteristic curve. The performance of the neural network in interpreting perfusion scintigrams alone was 0.79 (95% confidence limits 0.71-0.86). When one ventilation image (posterior view) was added to the perfusion study, the performance was 0.84 (0.77-0.90). This increase was statistically significant (P=0.022). The performance increased to 0.87 (0.81-0.93) when all perfusion and ventilation images were used, and the increase in performance from 0.79 to 0.87 was also statistically significant (P=0.016). The automated method presented here for the interpretation of lung scintigrams shows a significant

  7. Perfusion redistribution after a pulmonary-embolism-like event with contrast enhanced EIT.

    Science.gov (United States)

    Nguyen, D T; Bhaskaran, A; Chik, W; Barry, M A; Pouliopoulos, J; Kosobrodov, R; Jin, C; Oh, T I; Thiagalingam, A; McEwan, A L

    2015-06-01

    Recent studies showed that regional pulmonary perfusion can be reliably estimated using electrical impedance tomography (EIT) with the aid of hypertonic saline based contrast enhancement. Building on these successful studies, we studied contrast EIT for pulmonary perfusion defect caused by an artificially induced pulmonary embolism (PE) in a large ovine model (N = 8, 78 ± 7.8 kg). Furthermore, the efficacy of a less invasive contrast bolus of 0.77 ml kg(-1) of NaCl 3% was compared with a more concentrated bolus of 0.13 ml kg(-1) of NaCl 20%. Prior to the injection of each contrast bolus injection, ventilation was turned off to provide a total of 40 to 45 s of apnoea. Each bolus of impedance contrast was injected through a catheter into the right atrium. Pulmonary embolisation was performed by balloon occlusion of part of the right branch of the pulmonary trunk. Four parameters representing the kinetics of the contrast dilution in the lung were evaluated for statistical differences between baseline and PE, including peak value, maximum uptake, maximum washout and area under the curve of the averaged contrast dilution curve in each lung. Furthermore, the right lung to left lung (R2L) ratio of each the aforementioned parameters were assessed. While all of the R2L ratios yielded significantly different means between baseline and PE, it can be concluded that the R2L ratios of area under the curve and peak value of the averaged contrast dilution curve are the most promising and reliable in assessing PE. It was also found that the efficacy of the two types of impedance contrasts were not significantly different in distinguishing PE from baseline in our model.

  8. Lung perfusion scintigraphy in the diagnosis of peripheral pulmonary stenosis in patients after repair of Fallot tetralogy

    International Nuclear Information System (INIS)

    Sabiniewicz, R.; Chojnicki, M.; Alszewicz-Baranowska, J.; Erecinski, J.; Romanowicz, G.; Lass, P.; Bandurski, T.

    2002-01-01

    The frequency of peripheral pulmonary artery stenosis in patients after surgical repair of tetralogy of Fallot (TOF) ranges from 20 to 40%. This can be either primary or secondary to the surgical intervention. The influence of resulting lung perfusion alterations on the life quality of patients is difficult to predict. The aim of this study was to compare the utility of the diagnostic procedures in this group of patients, with particular focus on lung perfusion scintigraphy. This study comprised 104 patients who underwent repair of TOF at ages from 5 months to 25 years. The patients have been followed up for from 4.2 to 25 years. On the basis of chest X-ray peripheral pulmonary artery stenosis was suspected in 11 patients, in 12 on the basis of echocardiography examination. Lung perfusion scintigraphy has been performed on 87 patients. The disturbances in lung perfusion (mostly in the left lung) were show by means of lung perfusion scintigraphy in 43 (49%) of patients. In 27 of them heart catheterisation has been performed. Angiography revealed stenosis of the lung artery branch in 15/43 (34.9%) patients with abnormal perfusion lung scan and in 4/44 (9%) in patients with normal perfusion lung scan. Intervention procedures were carried out on 10 patients. Lung perfusion scintigraphy may prove a valuable, non-invasive screening tool in the assessment of patients after TOF repair, although both false-negative and false positive results may happen. Therefore, it should play an auxiliary role together with other diagnostic modalities. (author)

  9. Pulmonary Perfusion and Ventilation During Cardiopulmonary Bypass Are Not Associated with Improved Postoperative Outcomes After Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    Yiliam F Rodriguez-Blanco

    2016-11-01

    Full Text Available ObjectivesClinical trials of either pulmonary perfusion or ventilation during cardiopulmonary bypass are equivocal. We hypothesized that to achieve significant improvement in outcomes both interventions had to be concurrent.DesignRetrospective case-control studySettingsMajor academic tertiary referral medical centerParticipants274 consecutive patients who underwent open heart surgery with cardiopulmonary bypass 2009 - 2013.InterventionsThe outcomes of 86 patients who received pulmonary perfusion and ventilation during cardiopulmonary bypass were retrospectively compared to the control group of 188 patients.Measurements and Main ResultsRespiratory complications rates were similar in both groups (33.7% vs. 33.5%, as were the rates of postoperative pneumonia (4.7% vs. 4.3%, pleural effusions (13.9% vs. 12.2% and re-intubations (9.3% vs. 9.1%. Rates of adverse postoperative cardiac events including ventricular tachycardia (9.3% vs. 8.5% and atrial fibrillation (33.7% vs. 28.2% were equivalent in both groups. Incidence of sepsis (8.1% vs. 5.3%, postoperative stroke (2.3% vs. 2.1%, acute kidney injury (2.3% vs. 3.7% and renal failure (5.8% vs. 3.7% were likewise comparable. Despite similar transfusion requirements, coagulopathy (12.8% vs. 5.3%, p=0.031 and the need for mediastinal re-exploration (17.4% vs. 9.6%, p=0.0633 were observed more frequently in the pulmonary perfusion and ventilation group, but the difference did not reach the statistical significance. ICU and hospital stays, and the ICU readmission rates (7.0% vs. 8.0% were similar in both groups.ConclusionsSimultaneous pulmonary perfusion and ventilation during cardiopulmonary bypass were not associated with improved clinical outcomes.

  10. Ventilation and perfusion imaging by electrical impedance tomography: a comparison with radionuclide scanning

    NARCIS (Netherlands)

    Kunst, P. W.; Vonk Noordegraaf, A.; Hoekstra, O. S.; Postmus, P. E.; de Vries, P. M.

    1998-01-01

    Electrical impedance tomography (EIT) is a technique that makes it possible to measure ventilation and pulmonary perfusion in a volume that approximates to a 2D plane. The possibility of using EIT for measuring the left-right division of ventilation and perfusion was compared with that of

  11. Effect of endobronchial valve therapy on pulmonary perfusion and ventilation distribution.

    Directory of Open Access Journals (Sweden)

    Carmen Pizarro

    Full Text Available Endoscopic lung volume reduction (ELVR is an emerging therapy for emphysematous COPD. However, any resulting changes in lung perfusion and ventilation remain undetermined. Here, we report ELVR-mediated adaptations in lung perfusion and ventilation, as investigated by means of pulmonary scintigraphy.In this observational study, we enrolled 26 patients (64.9 ± 9.4 yrs, 57.7% male with COPD heterogeneous emphysema undergoing ELVR with endobronchial valves (Zephyr, Pulmonx, Inc.. Mean baseline FEV1 and RV were 32.9% and 253.8% predicted, respectively. Lung scintigraphy was conducted prior to ELVR and eight weeks thereafter. Analyses of perfusion and ventilation shifts were performed and complemented by correlation analyses between paired zones.After ELVR, target zone perfusion showed a mean relative reduction of 43.32% (p<0.001, which was associated with a significant decrease in target zone ventilation (p<0.001. Perfusion of the contralateral untreated zone and of the contralateral total lung exhibited significant increases post-ELVR (p = 0.002 and p = 0.005, respectively; both correlated significantly with the corresponding target zone perfusion adaptations. Likewise, changes in target zone ventilation correlated significantly with ventilatory changes in the contralateral untreated zone and the total contralateral lung (Pearson's r: -0.42, p = 0.04 and Pearson's r: -0.42, p = 0.03, respectively. These effects were observed in case of clinical responsiveness to ELVR, as assessed by changes in the six-minute walk test distance.ELVR induces a relevant decrease in perfusion and ventilation of the treated zone with compensatory perfusional and ventilatory redistribution to the contralateral lung, primarily to the non-concordant, contralateral zone.

  12. Magnetic Particle Imaging for Real-Time Perfusion Imaging in Acute Stroke.

    Science.gov (United States)

    Ludewig, Peter; Gdaniec, Nadine; Sedlacik, Jan; Forkert, Nils D; Szwargulski, Patryk; Graeser, Matthias; Adam, Gerhard; Kaul, Michael G; Krishnan, Kannan M; Ferguson, R Matthew; Khandhar, Amit P; Walczak, Piotr; Fiehler, Jens; Thomalla, Götz; Gerloff, Christian; Knopp, Tobias; Magnus, Tim

    2017-10-24

    The fast and accurate assessment of cerebral perfusion is fundamental for the diagnosis and successful treatment of stroke patients. Magnetic particle imaging (MPI) is a new radiation-free tomographic imaging method with a superior temporal resolution, compared to other conventional imaging methods. In addition, MPI scanners can be built as prehospital mobile devices, which require less complex infrastructure than computed tomography (CT) and magnetic resonance imaging (MRI). With these advantages, MPI could accelerate the stroke diagnosis and treatment, thereby improving outcomes. Our objective was to investigate the capabilities of MPI to detect perfusion deficits in a murine model of ischemic stroke. Cerebral ischemia was induced by inserting of a microfilament in the internal carotid artery in C57BL/6 mice, thereby blocking the blood flow into the medial cerebral artery. After the injection of a contrast agent (superparamagnetic iron oxide nanoparticles) specifically tailored for MPI, cerebral perfusion and vascular anatomy were assessed by the MPI scanner within seconds. To validate and compare our MPI data, we performed perfusion imaging with a small animal MRI scanner. MPI detected the perfusion deficits in the ischemic brain, which were comparable to those with MRI but in real-time. For the first time, we showed that MPI could be used as a diagnostic tool for relevant diseases in vivo, such as an ischemic stroke. Due to its shorter image acquisition times and increased temporal resolution compared to that of MRI or CT, we expect that MPI offers the potential to improve stroke imaging and treatment.

  13. A comparison between ventilation/perfusion scintigraphy and multislice spiral CT in the diagnosis of chronic thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Fang Wei; Wang Feng; He Zuoxiang; Lu Jinguo; Lv Bing; He Jianguo; Liu Zhihong

    2008-01-01

    Objective: Chronic thromboembolic pulmonary hypertension (CTEPH) is one of the important causes of pulmonary hypertension with poor prognosis. Several imaging techniques had been used to identify CTEPH. The aim of this study was to assess the reliability of ventilation/perfusion (V/Q) scintigraphy and multislice spiral CT pulmonary angiography (CTPA) in the diagnosis of chronic thromboembolic pulmonary hypertension, and the concordance rate (or 'agreement' as in the original article) between the two techniques. Methods: Forty-nine in-patients with pulmonary hypertension without history of con- genital heart disease, valvular heart disease and acute pulmonary embolism were included in this study. All these patients underwent V/Q scintigraphy as well as CTPA for detecting CTEPH. The final diagnosis was confirmed by pulmonary angiograpy. The results of V/Q scintigraphy and CTPA were compared with the χ 2 test. Results: The sensitivity, specificity and accuracy of V/Q scintigraphy in diagnosis of CTEPH was 100.0% (17/17), 71.9% (23/32) and 81.6% (40/49), respectively, and those of CTPA was 94.1% (16/17), 81.2% (26/32) and 85.7% (42/49), respectively. The concordance rate was 75.5% (37/49, Kappa=0.513), no statistically significant difference (χ 2 =0.75, P > 0.05 ) was found between V/Q scintigraphy and CTPA. Conclusion: Both V/Q scintigraphy and CTPA are reliable to diagnose CTEPH. (authors)

  14. Renal perfusion image using harmonic ultrasound with microbble contrast agent: preliminary study

    International Nuclear Information System (INIS)

    Kim, Jung Hoon; Choi, Jae Ho; Han, Dong Chul; Lee, Hi Bahl; Choi, Deuk Lin; Eun, Hyo Won; Lee, Hun Jae

    2003-01-01

    To compare, in terms of their feasibility and normal range, 99m Tc-DTPA renal perfusion imaging and renal perfusion imaging using harmonic ultrasound (US) with a microbubble contrast agent for the evaluation of renal perfusion after renal transplantation. During a six-month period, thirty patients who had received a renal transplant underwent both 99m Tc-DTPA renal perfusion imaging and renal perfusion imaging using harmonic US with a microbubble contrast agent. Sonographic renal perfusion images were obtained before and after a bolus injection of the microbubble contrast agent Levovist TM (SH U 5084; Schering AG, Berlin, Germany) every 3 seconds for 3 minutes. Sonographic renal perfusion images were converted into a renal perfusion curve by a computer program and T peak of the curve thus obtained was compared with that of the 99m Tc-DTPA curve. Average T peak of the 99m Tc-DTPA renal perfusion curve was 16.2 seconds in the normal group and 39.6 seconds in the delayed perfusion group, while average T peak of the sonographic renal perfusion curve was 23.7 seconds and 46.2 seconds, respectively. T peak of the sonographic renal perfusion curve showed a good correlation with that of the 99m Tc-DTPA curve (correlation coefficient=0.8209; p=0.0001). The cut-off value of T peak of the sonographic renal perfusion curve was 35 seconds (sensitivity=90%, specificity=95%). In patients who have received a renal transplant, the findings of renal perfusion imaging using harmonic US with a microbubble contrast agent show close correlation with those of 99m Tc-DTPA renal perfusion imaging. The optimal cut-off value of T peak of the sonographic renal perfusion curve was 35 seconds

  15. Clinical significance of ventilation/perfusion scans in collagen disease patients

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Kenzo; Kobayashi, Takeshi [Tokyo Metropolitan Hiro-o Hospital (Japan); Kamata, Noriko; Inokuma, Shigeko; Terada, Hitoshi; Yokoyama, Yoshiaki; Abe, Katsumi; Mochizuki, Takao

    2000-12-01

    The purpose of this study was to detect disturbances in pulmonary circulation in collagen disease patients by means of a non-invasive technique. Ventilation/perfusion scans with {sup 133}Xe gas and {sup 99m}Tc-macroaggregated albumin (MAA) were performed in 109 patients with various collagen diseases. Functional images of V, Vol, Q and V/Q ratio were obtained at total lung capacity. Wash-out time was calculated from the wash-out curve. Whole body scans were performed in 65 patients to evaluate intra-pulmonary shunts. Increased V/Q areas were observed in 74 patients (67.9%), suggesting some impairment of pulmonary perfusion. Decreased perfusion, probably due to vasculitis or intravascular microcoagulation, was observed often, even in patients without pulmonary fibrosis. Shunt ratios over 10% were observed in 8 of the 65 patients (12.3%), indicating formation of PA-PV shunts secondary to peripheral vascular impairment. Wash-out time was prolonged in 37 patients (33.9%), shortened in 18 (16.5%), and within the normal range in 54 (49.6%). The prolonged and normal wash-out times in the patients with pulmonary fibrosis may represent obstructive changes in the small airways superimposed on the fibrosis. Ventilation/perfusion scans are a very useful tool for evaluating collagen lung diseases, and they might contribute to treatment decisions for the patients. (author)

  16. Myocardial perfusion SPECT imaging in patients with myocardial bridging

    International Nuclear Information System (INIS)

    Fang Wei; Qiu Hong; Yang Weixian; Wang Feng; He Zuoxiang

    2008-01-01

    Objective: Stress myocardial perfusion SPECT imaging was used to assess myocardial ischemia in patients with myocardial bridging. Methods: Ninety-six patients with myocardial bridging of the left anterior descending artery documented by coronary angiography were included in this study. All under- went exercise or pharmacological stress myocardial perfusion SPECT assessing myocardial ischemia. None had prior myocardial infarction. One year follow-up by telephone interview was performed in all patients. Results The mean stenotic severity of systolic phase on angiography was (65 ± 19)%. In the SPECT study, 20 of 96 (20.8%) patients showed abnormal perfusion. This percentage was significantly higher than that of stress electrocardiogram (ECG). The higher positive rate of SPECT perfusion images was showed in the group of patients with severe systolic narrowing (≥75%) than that with mild-to-moderate systolic narrowing (50% vs 6.3%, P<0.001). The prevalence of abnormal image was significantly higher in ELDERLY PEOPLE; patients with STT change on rest ECG than in those with normal rest ECG (54.2% vs 9.7%, P<0.001). During follow-up, one patient with abnormal SPECT perfusion image sustained angina and accepted percutaneous coronary intervention, and no cardiac event occurred in patients with normal images. Conclusions: Stress myocardial perfusion SPECT imaging can be used effectively for assessing myocardial ischemia and has potential prognostic value for patients with myocardial bridging. (authors)

  17. Cerebral perfusion imaging in HIV positive patients

    International Nuclear Information System (INIS)

    Kundley, Kshama; Chowdhury, D.; Lele, V.R.; Lele, R.D.

    1998-01-01

    Full text: Twelve human immunodeficiency virus (HIV) positive patients were studied by SPECT cerebral perfusion imaging 1 hour post injection of 15 mCi of 99m Tc-ECD under ideal conditions with a triple head gamma camera (Prism 3000 X P LEUHR), fanbeam collimators followed by Folstein Mini Mental Status Examination (FMMSE) and AIDS dementia complex (ADC) staging on the same day. All 12 patients were male, in the age range of 23-45 y (mean 31 y). The infected status was diagnosed by ELISA (10 patients) or Western blot (5 patients). The interval between diagnosis and imaging ranged from 1 month - 35 months (mean 15.3 months). Two patients were alcoholic and 2 were smokers. None of them had CNS disorder clinically. ADC staging and FMMSE could be performed in 4 patients. Two patients were normal (stage 0) and 2 were subclinical (stage 0.5) on ADC staging. FMMSE revealed normal or near normal status (mean score 35; maximum score 36). Cerebral perfusion images were interpreted simultaneously by 3 observers blind towards history and examination using semi-quantitative and quantitative methods by consensus. It revealed multiple areas of hypoperfusion, viz. temporal (11 patients (91 %), parietal 10 patients (83%), frontal 9 patients (75%, pre and post central gyrus 7 patients (58%), occipital 6 patients (50%) cingulate gyrus and cerebellum 5 patients (41%) and thalamic in 2 patients (16%). Hyper perfusion in caudate nuclei was noted in 10 patients (83%). The study reveals presence of multiple perfusion abnormalities on cerebral perfusion imaging in HIV positive patients who have normal/near normal mental status suggesting precedence of perfusion abnormality over clinically apparent mental deficit

  18. Lung inhalation scintigraphy with radioactive aerosols in several pulmonary diseases

    International Nuclear Information System (INIS)

    Martins, L.R.; Marioni Filho, H.; Romaldini, H.; Uehara, C.; Alonso, G.

    1983-01-01

    The pulmonary ventilation scintigraphy with 99m Tc diethylene-triamine-pentaacetate (99mTc-DTPA) delivered through a new nebulizer system when analyzed together with the classic lung perfusion scintigraphy with 99mTc-labeled albumin macroaggregates (99mTcMAA) is a very important diagnostic tool in several pulmonary diseases. Several aspects of the lung ventilation-perfusion scintigraphy are studied in 15 people with no lung disease, smokers and nonsmokers. The findings with the lung ventilation-perfusion scintigraphy are also discussed in 34 patients with several pulmonary diseases: lung cancer, chronic obstructive lung disease, policystic pulmonary disease, and pulmonary embolims. The authors concluded that the procedure is a valuable diagnostic tool in several pulmonary diseases, especially because good lung images are obtained, no side effects were detected, the technique is ease and low cost, and it brings new informations, not available with other diagnostic methods. (author)

  19. Non-invasive quantitative pulmonary V/Q imaging using Fourier decomposition MRI at 1.5T

    Energy Technology Data Exchange (ETDEWEB)

    Kjoerstad, Aasmund; Corteville, Dominique M.R.; Zoellner, Frank G.; Schad, Lothar R. [Heidelberg Univ., Medical Faculty Mannheim (Germany). Computer Assisted Clinical Medicine; Henzler, Thomas [Heidelberg Univ., Medical Faculty Mannheim (Germany). Inst. of Clinical Radiology and Nuclear Medicine; Schmid-Bindert, Gerald [Heidelberg Univ., Medical Faculty Mannheim (Germany). Interdisciplinary Thoracic Oncology

    2015-07-01

    Techniques for quantitative pulmonary perfusion and ventilation using the Fourier Decomposition method were recently demonstrated. We combine these two techniques and show that ventilation-perfusion (V/Q) imaging is possible using only a single MR acquisition of less than thirty seconds. The Fourier Decomposition method is used in combination with two quantification techniques, which extract baselines from within the images themselves and thus allows quantification. For the perfusion, a region assumed to consist of 100% blood is utilized, while for the ventilation the zero-frequency component is used. V/Q-imaging is then done by dividing the quantified ventilation map with the quantified perfusion map. The techniques were used on ten healthy volunteers and fifteen patients diagnosed with lung cancer. A mean V/Q-ratio of 1.15±0.22 was found for the healthy volunteers and a mean V/Q-ratio of 1.93±0.83 for the non-afflicted lung in the patients. Mean V/Q-ratio in the afflicted (tumor-bearing) lung was found to be 1.61±1.06. Functional defects were clearly visible in many of the patient images, but 5 of 15 patient images had to be excluded due to artifacts or low SNR, indicating a lack of robustness. Conclusion Non-invasive, quantitative V/Q-imaging is possible using Fourier Decomposition MRI. The method requires only a single acquisition of less than 30 seconds, but robustness in patients remains an issue.

  20. Non-invasive quantitative pulmonary V/Q imaging using Fourier decomposition MRI at 1.5T.

    Science.gov (United States)

    Kjørstad, Åsmund; Corteville, Dominique M R; Henzler, Thomas; Schmid-Bindert, Gerald; Zöllner, Frank G; Schad, Lothar R

    2015-12-01

    Techniques for quantitative pulmonary perfusion and ventilation using the Fourier Decomposition method were recently demonstrated. We combine these two techniques and show that ventilation-perfusion (V/Q) imaging is possible using only a single MR acquisition of less than thirty seconds. The Fourier Decomposition method is used in combination with two quantification techniques, which extract baselines from within the images themselves and thus allows quantification. For the perfusion, a region assumed to consist of 100% blood is utilized, while for the ventilation the zero-frequency component is used. V/Q-imaging is then done by dividing the quantified ventilation map with the quantified perfusion map. The techniques were used on ten healthy volunteers and fifteen patients diagnosed with lung cancer. A mean V/Q-ratio of 1.15 ± 0.22 was found for the healthy volunteers and a mean V/Q-ratio of 1.93 ± 0.83 for the non-afflicted lung in the patients. Mean V/Q-ratio in the afflicted (tumor-bearing) lung was found to be 1.61 ± 1.06. Functional defects were clearly visible in many of the patient images, but 5 of 15 patient images had to be excluded due to artifacts or low SNR, indicating a lack of robustness. Non-invasive, quantitative V/Q-imaging is possible using Fourier Decomposition MRI. The method requires only a single acquisition of less than 30 seconds, but robustness in patients remains an issue. Copyright © 2015. Published by Elsevier GmbH.

  1. Inapparent pulmonary vascular disease in an ex-heroin user

    International Nuclear Information System (INIS)

    Antonelli Incalzi, R.; Ludovico Maini, C.; Giuliano Bonetti, M.; Campioni, P.; Pistelli, R.; Fuso, L.

    1986-01-01

    A severe pulmonary vascular derangement, usually reported in drug addicts, was diagnosed in a 28-year-old asymptomatic ex-heroin user by means of fortuitously performed pulmonary perfusion imaging. Neither physical findings nor pulmonary function tests, aroused suspicion of the diagnosis. A search for asymptomatic pulmonary vascular disease probably should be undertaken in drug addicts

  2. Basic consideration of diffusion/perfusion imaging

    International Nuclear Information System (INIS)

    Tamagawa, Yoichi; Kimura, Hirohiko; Matsuda, Tsuyoshi; Kawamura, Yasutaka; Nakatsugawa, Shigekazu; Ishii, Yasushi; Sakuma, Hajime; Tsukamoto, Tetsuji.

    1990-01-01

    In magnetic resonance imaging (MRI), microscopic motion of biological system such as molecular diffusion of water and microcirculation of blood in the capillary network (perfusion) has been proposed to cause signal attenuation as an intravoxel incoherent motion (IVIM). Quantitative imaging of the IVIM phenomenon was attempted to generate from a set of spin-echo (SE) sequences with or without sensitization by motion probing gradient (MPG). The IVIM imaging is characterized by a parameter, apparent diffusion coefficient (ADC), which is an integration of both the diffusion and the perfusion factor on voxel-by-voxel basis. Hard ware was adjusted to avoid image artifact mainly produced by eddy current. Feasibility of the method was tested using bottle phantom filled with water at different temperature and acetone, and the calculated ADC values of these media corresponded well with accepted values of diffusion. The method was then applied to biological system to investigate mutual participation of diffusion/perfusion on the ADC value. The result of tumor model born on nude mouse suggested considerable participation of perfusion factor which immediately disappeared after sacrificing the animal. Meanwhile, lower value of sacrificed tissue without microcirculation was suggested to have some restriction of diffusion factor by biological tissue. To substantiate the restriction effect on the diffusion, a series of observation have made on a fiber phantom, stalk of celory with botanical fibers and human brain with nerve fibers, in applying unidirectional MPG along the course of these banch of fiber system. The directional restriction effect of diffusion along the course of fiber (diffusion anisotrophy) was clearly visualized as directional change of ADC value. The present method for tissue characterization by diffusion/perfusion on microscopic level will provide a new insight for evaluation of functional derangement in human brain and other organs. (author)

  3. Ventilation-perfusion lung imaging in diaphragmatic paralysis

    International Nuclear Information System (INIS)

    Chopra, S.K.; Taplin, G.V.

    1977-01-01

    Clinical, radiological, physiological, and lung imaging findings from a patient with paralysis of the diaphragm are described. Dyspnea, hypoxemia and hypercapnia increased when the patient changed from the upright to the supine positions. Ventilation (V) and perfusion (P) images of the right lung appeared to be relatively normal and remained nearly the same in the upright and supine positions. In contrast, V/P images of the left lung were smaller than those of the right lung in the upright position and decreased further in the supine position. In addition, the size of the ventilation image was much smaller than that of the perfusion

  4. Role of combined perfusion/ventilation scanning in diagnosis of pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Moustafa, H; Elhaddad, SH; Wageeh, SH; Samy, A; Abdo, S [Nuclear medicine and radiology department, faculty of medicine and Cairo university, Cairo, (Egypt)

    1995-10-01

    This study was conducted on 200 patients with suspected pulmonary embolism. Their age ranged 9-74 years with a mean age of 41.9+14.6 years.The commonest symptoms were dyspnea; chest pain and haemoptysis in 67.5%,49.5% and 14.5% respectively, whereas the main signs were tachycardia in 64.5% followed by rales and oedema of lower limbs in 28.5% and 14% respectively. Cardiac diseases were presenting the main risk factors in 47% followed by DVT, surgery, COLD in 24%,10% and 9.5% respectively. perfusion lung scan was normal in 27.5%, whereas low, intermediate and high probability scans were seen in 7%,23.5% and 42% respectively. The addition of ventilation scan, change probability of perfusion defects into 18.5%,19% and 31.5% in low, intermediate and high probability scans respectively. In addition 3.5% of patient diagnosed as non- embolic disease. There was significant correlation with increase number of symptoms and signs in relation to scan probability in both whole group and high probability group. Also, the incidence of pulmonary embolism appear to be additive with increase number of risk factors in the group of high probability scans. 3 figs., 3 tabs.

  5. Role of combined perfusion/ventilation scanning in diagnosis of pulmonary embolism

    International Nuclear Information System (INIS)

    Moustafa, H.; Elhaddad, SH.; Wageeh, SH.; Samy, A.; Abdo, S.

    1995-01-01

    This study was conducted on 200 patients with suspected pulmonary embolism. Their age ranged 9-74 years with a mean age of 41.9+14.6 years.The commonest symptoms were dyspnea; chest pain and haemoptysis in 67.5%,49.5% and 14.5% respectively, whereas the main signs were tachycardia in 64.5% followed by rales and oedema of lower limbs in 28.5% and 14% respectively. Cardiac diseases were presenting the main risk factors in 47% followed by DVT, surgery, COLD in 24%,10% and 9.5% respectively. perfusion lung scan was normal in 27.5%, whereas low, intermediate and high probability scans were seen in 7%,23.5% and 42% respectively. The addition of ventilation scan, change probability of perfusion defects into 18.5%,19% and 31.5% in low, intermediate and high probability scans respectively. In addition 3.5% of patient diagnosed as non- embolic disease. There was significant correlation with increase number of symptoms and signs in relation to scan probability in both whole group and high probability group. Also, the incidence of pulmonary embolism appear to be additive with increase number of risk factors in the group of high probability scans. 3 figs., 3 tabs

  6. Quantitative lung perfusion evaluation using Fourier decomposition perfusion MRI.

    Science.gov (United States)

    Kjørstad, Åsmund; Corteville, Dominique M R; Fischer, Andre; Henzler, Thomas; Schmid-Bindert, Gerald; Zöllner, Frank G; Schad, Lothar R

    2014-08-01

    To quantitatively evaluate lung perfusion using Fourier decomposition perfusion MRI. The Fourier decomposition (FD) method is a noninvasive method for assessing ventilation- and perfusion-related information in the lungs, where the perfusion maps in particular have shown promise for clinical use. However, the perfusion maps are nonquantitative and dimensionless, making follow-ups and direct comparisons between patients difficult. We present an approach to obtain physically meaningful and quantifiable perfusion maps using the FD method. The standard FD perfusion images are quantified by comparing the partially blood-filled pixels in the lung parenchyma with the fully blood-filled pixels in the aorta. The percentage of blood in a pixel is then combined with the temporal information, yielding quantitative blood flow values. The values of 10 healthy volunteers are compared with SEEPAGE measurements which have shown high consistency with dynamic contrast enhanced-MRI. All pulmonary blood flow (PBF) values are within the expected range. The two methods are in good agreement (mean difference = 0.2 mL/min/100 mL, mean absolute difference = 11 mL/min/100 mL, mean PBF-FD = 150 mL/min/100 mL, mean PBF-SEEPAGE = 151 mL/min/100 mL). The Bland-Altman plot shows a good spread of values, indicating no systematic bias between the methods. Quantitative lung perfusion can be obtained using the Fourier Decomposition method combined with a small amount of postprocessing. Copyright © 2013 Wiley Periodicals, Inc.

  7. Quantitative evaluation of regional blood flow in pulmonary sarcoidosis with Bull's eye analysis

    International Nuclear Information System (INIS)

    Akaki, Shiro

    1991-01-01

    Lung perfusion scintigraphy was performed in 23 patients with pulmonary sarcoidosis and in 11 normal volunteers. Bull's eye analysis was used to analyze regional pulmonary blood flow quantitatively. First, whole lung perfusion images were divided into three regions by three concentric circles. Then radial axes were projected from the center to define 36 x 10deg sectors. The counts for each sector were calculated and a Bull's eye image was displayed. The counts were compared with the lower limit of normal (mean -2SD), and as the indices of reduction in perfusion, extent score (ES) and severity score (SS) were calculated. ES and SS showed significant reduction in perfusion 16 patients (70%) with sarcoidosis. In stage II sarcoidosis, both ES and SS were significantly higher than in stage I sarcoidosis (p 67 Ga scintigraphy findings. In comparison with clinical data, ES had a positive correlation with serum angiotensin-converting enzyme activity (p + /CD8 + ratio (p<0.05). The Bull's eye analysis was considered useful for the quantitative evaluation of regional pulmonary blood flow in pulmonary sarcoidosis, and it was suggested that the mechanism of reduction in perfusion might result mainly in its alveolitis and angitis. Ventilation abnormality, which may happen prior to reduction in perfusion, may be an important factor of reduction in perfusion. (author)

  8. Diagnóstico por imagem do tromboembolismo pulmonar agudo Imaging of acute pulmonary thromboembolism

    Directory of Open Access Journals (Sweden)

    C. Isabela S. Silva

    2004-10-01

    Full Text Available O diagnóstico do tromboembolismo pulmonar agudo é baseado na probabilidade clínica, uso do dímero D (quando disponível e na avaliação por imagem. Os principais métodos de imagem utilizados no diagnóstico são representados por cintilografia ventilação-perfusão, angiografia pulmonar e tomografia computadorizada (TC. Na última década vários estudos têm demonstrado que a TC espiral apresenta elevada sensibilidade e especificidade no diagnóstico de tromboembolismo pulmonar agudo. Uma melhor avaliação das artérias pulmonares tornou-se possível com a recente introdução dos equipamentos de TC espirais com multidetectores. Vários pesquisadores têm sugerido que a angiografia pulmonar por TC espiral deve substituir a cintilografia na avaliação de pacientes com suspeita clinica de tromboembolismo pulmonar agudo. Os autores discutem os principais métodos de imagem utilizados no diagnóstico de tromboembolismo pulmonar agudo enfatizando o papel da TC espiral.The diagnosis of acute pulmonary thromboembolism is based on the clinical probability, use of D-dimer (when available and imaging. The main imaging modalities used in the diagnosis are ventilation-perfusion (V/Q, scintigraphy, angiography, and computed tomography (CT. In the last decade several studies have demonstrated that spiral CT has a high sensitivity and specificity in the diagnosis of acute pulmonary thromboembolism. The evaluation of the pulmonary arteries has further improved with the recent introduction of multidetector spiral CT scanners. Various investigators have suggested that spiral CT pulmonary angiography should replace scintigraphy in the assessment of patients whose symptoms are suggestive of acute PE. This article discusses the role of the various imaging modalities in the diagnosis of acute pulmonary thromboembolism with emphasis on the role of spiral CT.

  9. Recent lung imaging studies

    International Nuclear Information System (INIS)

    Taplin, G.V.; Chopra, S.K.

    1976-01-01

    Radionuclide lung imaging procedures have been available for 11 years but only the perfusion examination has been used extensively and mainly for the diagnosis of pulmonary embolism (P.E.). Its ability to reveal localized ischemia makes it a valuable test of regional lung function as well as a useful diagnostic aid in P.E. Although it had been recognized for several years that chronic obstructive pulmonary disease (COPD) can cause lung perfusion defects which may simulate pulmonary embolism, relatively little use has been made of either the radioxenon or the radioaerosol inhalation lung imaging procedures until the last few years as a means of distinguishing P.E. from COPD. In this review emphasis is placed on our recent experience with both of these inhalation procedures in comparison with pulmonary function tests and roentgenography for the early detection of COPD in population studies. Equal emphasis is given to simultaneous aerosol ventilation-perfusion (V/P) imaging for a functional diagnosis of P.E. Two new developments in regional lung diffusion imaging, performed after the inhalation of radioactive gases and/or rapidly absorbed radioaerosols are described. The experimental basis for their potential clinical application in pulmonary embolism detection is presented

  10. Surgical thromboendarterectomy for chronic thromboembolic pulmonary hypertension using circulatory arrest with selective antegrade cerebral perfusion

    NARCIS (Netherlands)

    Zeebregts, CJAM; Dossche, KM; Morshuis, WJ; Knaepen, PJ; Schepens, MAAM

    The use of circulatory arrest with selective antegrade cerebral perfusion is described in a 59-year-old man who underwent thrombendarterectomy for chronic thromboembolic pulmonary hypertension. The postoperative course was uneventful. The described surgical technique may prevent the patient from

  11. Myocardial perfusion imaging with dual energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, SMG-SNU Boramae Medical Center, Seoul (Korea, Republic of); De Cecco, Carlo N. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncology and Pathology, University of Rome “Sapienza”, Rome (Italy); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Spandorfer, Adam; Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States)

    2016-10-15

    Highlights: • Stress dual-energy sCTMPI offers the possibility to directly detect the presence of myocardial perfusion defects. • Stress dual-energy sCTMPI allows differentiating between reversible and fixed myocardial perfusion defects. • The combination of coronary CT angiography and dual-energy sCTMPI can improve the ability of CT to detect hemodynamically relevant coronary artery disease. - Abstract: Dual-energy CT (DECT) enables simultaneous use of two different tube voltages, thus different x-ray absorption characteristics are acquired in the same anatomic location with two different X-ray spectra. The various DECT techniques allow material decomposition and mapping of the iodine distribution within the myocardium. Static dual-energy myocardial perfusion imaging (sCTMPI) using pharmacological stress agents demonstrate myocardial ischemia by single snapshot images of myocardial iodine distribution. sCTMPI gives incremental values to coronary artery stenosis detected on coronary CT angiography (CCTA) by showing consequent reversible or fixed myocardial perfusion defects. The comprehensive acquisition of CCTA and sCTMPI offers extensive morphological and functional evaluation of coronary artery disease. Recent studies have revealed that dual-energy sCTMPI shows promising diagnostic accuracy for the detection of hemodynamically significant coronary artery disease compared to single-photon emission computed tomography, invasive coronary angiography, and cardiac MRI. The aim of this review is to present currently available DECT techniques for static myocardial perfusion imaging and recent clinical applications and ongoing investigations.

  12. Relative preservation of peripheral lung function in smoking-related pulmonary emphysema: assessment with {sup 99m}Tc-MAA perfusion and dynamic {sup 133}Xe SPET

    Energy Technology Data Exchange (ETDEWEB)

    Suga, Kazuyoshi; Kume, Norihiko; Matsunaga, Naofumi; Ogasawara, Nobuhiko; Motoyama, Kazumi; Hara, Akiko; Matsumoto, Tsuneo [Department of Radiology, Yamaguchi University School of Medicine, Ube, Yamaguchi (Japan)

    2000-07-01

    In this study the cross-sectional functional differences between the central and peripheral lung in smokers with pulmonary emphysema were evaluated by lung perfusion and dynamic xenon-133 single-photon emission tomography (SPET). The subjects were 81 patients with a long-term smoking history and relatively advanced emphysema, 17 non-smoker patients with non-obstructive lung diseases and six healthy non-smokers. Regional lung functional difference between the peripheral and central lung was assessed in the upper, middle and lower lung zones by technetium-99m macroaggregated albumin SPET and dynamic {sup 133}Xe SPET. The distribution of emphysematous changes was assessed by density-mask computed tomography (CT) images which depicted abnormally low attenuation areas (LAAs) of less than -960 Hounsfield units. Two hundred and eighty-eight (59.2%) lung zones of 63 (77.7%) patients with pulmonary emphysema showed relative preservation of lung function in the peripheral lung, with a curvilinear band of normal perfusion (a stripe sign) and a significantly faster {sup 133}Xe half-clearance time (T{sub 1/2}) than in central lung (P<0.0001). Of these lung zones, 256 (88.8%) showed central-dominant LAA distributions on density-mask CT images, but the remaining 32 zones did not show any regional preference in LAA distribution. Conversely, 117 (24.0%) lung zones of 19 (23.4%) patients showed periphery-dominant perfusion defects and LAA distributions, with significantly prolonged T{sub 1/2} in the peripheral lung area (P<0.0001). The remaining 81 lung zones of the patients with pulmonary emphysema and all the lung zones of the healthy subjects and patients with non-obstructive lung diseases did not show a stripe sign, and no differences were observed in T{sub 1/2} values and LAA distributions between the central and peripheral lung. Relative preservation of peripheral lung function seems to be a characteristic feature in smoking-related pulmonary emphysema, and may indicate a

  13. Ventilation-perfusion-lungscintigraphy using PET and {sup 68}Ga-labeled radiopharmaceuticals; Ventilations-Perfusions-Lungenszintigraphie mit der PET und {sup 68}Ga-markierten Radiopharmaka

    Energy Technology Data Exchange (ETDEWEB)

    Kotzerke, J. [Technische Univ. Dresden (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Technische Univ. Dresden (Germany). OncoRay - Zentrum fuer Innovationskompetenz Strahlenforschung in der Onkologie; Forschungszentrum Dresden-Rossendorf e.V. (FZR) (Germany). PET-Zentrum; Andreeff, M.; Wunderlich, G.; Zoephel, K. [Technische Univ. Dresden (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Wiggermann, P. [Technische Univ. Dresden (Germany). Inst. und Poliklinik fuer Diagnostische Radiologie

    2010-07-01

    Aim: Imaging of lung perfusion with positron emission tomography (PET) is already possible with {sup 68}Ga labeled denaturized albumin. The purpose of our study was to produce and test a {sup 68}Ga labeled aerosol (Galligas {sup registered}) for ventilation and {sup 68}Ga labeled albumin particles (microspheres) for perfusion imaging with PET. Patients, methods: Galligas was produced by simmering and burning generator eluted {sup 68}Ga solution (100 MBq/0.1ml) in an ordinary technegas generator. Fifteen patients with suspicion on pulmonary embolism underwent PET/CT (Biograph 16) after inhalation of Galligas and application of {sup 68}Ga labeled microspheres. A low dose CT was acquired for attenuation correction (AC). Images were reconstructed with and without AC. The inhaled activity was calculated compared to the activity injected. Results: Inhaled radioaerosol Galligas demonstrated typical distribution as known from {sup 99m}Tc-labeled technegas with homogeneous distribution in lung without hilar deposits. Attenuation corrected images resulted in artefacts in the lung base. Therefore, non-corrected images were used for making the results. Three out of fifteen patients showed a deficient perfusion whereas ventilation was normal corresponding to pulmonary embolism. Conclusion: Lung scintigraphy with PET is feasible. Galligas is simple to produce (analogously to technegas). {sup 68}Ga labeled microspheres are available. The method is applicable to daily routine and rendered clinically relevant informations. (orig.)

  14. Brain perfusion imaging with iodinated amines

    International Nuclear Information System (INIS)

    Kung, H.F.

    1989-01-01

    Traditional nuclear medicine brain study using 99m Tc pertechnetate, glucoheptonate or diethlenetriaminepentacetic acid (DTPA) and planar imaging has experienced a significant decline in the past 10 years. This is mainly due to the introduction of X-ray CT and more recently the nuclear magnetic resonance (NMR) imaging, by which detailed morphology of the brain, including the detection of breakdown of the blood-brain barrier, can be obtained. The nuclear medicine brain imaging is only prescribed as a complementary test when X-ray CT is negative or equivocal and clinical suspicion remains. The attention of nuclear medicine brain imaging has been shifted from the detection of the breakdown of the blood-brain barrier to the study of brain function-perfusion, metabolism, and receptor binding, etc. The functional brain imaging provides diagnostic information usually unattainable by other radiological techniques. In this article, the iodinated amines as brain perfusion imaging agents are reviewed. Potential clinical application of these agents is discussed

  15. Dynamic CT myocardial perfusion imaging identifies early perfusion abnormalities in diabetes and hypertension : Insights from a multicenter registry

    NARCIS (Netherlands)

    Vliegenthart, Rozemarijn; De Cecco, Carlo N.; Wichmann, Julian L.; Meinel, Felix G.; Pelgrim, Gert Jan; Tesche, Christian; Ebersberger, Ullrich; Pugliese, Francesca; Bamberg, Fabian; Choe, Yeon Hyeon; Wang, Yining; Schoepf, U. Joseph

    2016-01-01

    Background: To identify patients with early signs of myocardial perfusion reduction, a reference base for perfusion measures is needed. Objective: To analyze perfusion parameters derived from dynamic computed tomography perfusion imaging (CTPI) in patients with suspected coronary artery disease

  16. Study on thallium-201 myocardial perfusion scanning for detection of right ventricular hypertrophy in chronic pulmonary disease

    International Nuclear Information System (INIS)

    Kawai, Seiki

    1980-01-01

    Thallium-201 myocardial perfusion scanning was performed in 34 patients with chronic pulmonary disease for the purpose of detecting right ventricular hypertrophy. Thallium-201 activity ratio of left ventricle plus ventricular septum/right ventricle (TAR) was significantly correlated with hemodynamic findings such as pulmonary arterial mean pressure (r = -0.75, p 2 (p < 0.001). Assuming that TAR < 2 or TAR = 2 would indicate pulmonary hypertension, sensitivity was 95%, specificity 79%, validity score 75%, false positive 14% and false negative was 8%. TAR was compared with left to right ventricular mass ratio using Fulton's method in 6 autopsied patients in whom thallium-201 myocardial perfusion scanning were performed within three months before death. TAR closely correlated with left to right ventricular mass ratio (r = 0.978, p < 0.001). The comparison of validity of TAR with those of electrocardiographic interpretation according to WHO, Sasamoto, Roman or Milnor for the detection of right ventricular hypertrophy revealed the former was much superior to all of latters. From the results obtained, it may be inferred that TAR reflects the degree of pulmonary hypertension and anatomical right ventricular hypertrophy and is a useful non-invasive method to detect right ventricular hypertrophy in chronic pulmonary disease. (J.P.N.)

  17. The evaluation of the degree of impairment of pulmonary perfusion in lung cancer patients treated by radiotherapy by the quantification of nonuniform distribution of lung perfusion scintigraphy SPECT

    International Nuclear Information System (INIS)

    Mitomo, Osamu; Tsunoda, Takashi; Kuwabara, Hidemasa

    2004-01-01

    By means of quantifying the nonuniform distribution of pulmonary perfusion in Lung Perfusion Scintigraphy SPECT (single photon emission tomography), which is called ''SPECT'' for short, we evaluated the degree of functional impairment of pulmonary perfusion in non-operated lung cancer patients treated by the radiotherapy. Sixty-eight patients with non-operated lung cancer treated with radiotherapy, and who either received or did not receive chemotherapy, from February, 1996 to August, 2002, were examined using SPECT within 6 weeks prior to, or within 2 weeks following radiotherapy. This group was called ''irradiated lung cancer patients''. Twenty-six patients, who were called ''follow-up irradiated lung cancer patients'', were reexamined within four weeks after radiotherapy. On the other hand, 323 patients without lung cancer, who were subdivided into four groups; pulmonary, cardiac, cardio-pulmonary, and non-cardiopulmonary. The SPECT was examined in the supine position after infusing Tc-99m-MAA, 185 MBq in a bolus, mainly into an antecubital vein with the patient's arm elevated. From reconstructed SPECT images, the volume of lung as a whole calculated at 10% of thresholds was assumed to be the ''Baseline Lung Perfusion Volume'' (BPV), and the functional volume rates were calculated in 10% threshold widths from 10% to 100% of the threshold. Assuming the total absolute differences in functional volume rate between each subject and the control to be the distribution index of the lung as a whole (D index), we quantified the degree of nonuniform distribution of the lung as a whole in each subject. In the same way, the distribution index of the left or right lung respectively was calculated as D l or D r index assuming the volume of left or right lung were calculated at 10% of the threshold as left or right BPV and calculating the functional volume rates of each lung in 10% threshold widths from 10% to 100% of the threshold. The D index of irradiated lung cancer

  18. Lung scans with significant perfusion defects limited to matching pleural effusions have a low probability of pulmonary embolism

    International Nuclear Information System (INIS)

    Datz, F.L.; Bedont, R.A.; Taylor, A.

    1985-01-01

    Patients with a pleural effusion on chest x-ray often undergo a lung scan to exclude pulmonary embolism (PE). According to other studies, when the scan shows a perfusion defect equal in size to a radiographic abnormality on chest x-ray, the scan should be classified as indeterminate or intermediate probability for PE. However, since those studies dealt primarily with alveolar infiltrates rather than pleural effusions, the authors undertook a retrospective study to determine the probability of PE in patients with pleural effusion and a matching perfusion defect. The authors reviewed 451 scans and x-rays of patients studied for suspected PE. Of those, 53 had moderate or large perfusion defects secondary to pleural effusion without other significant (>25% of a segment) effusion without other significant (>25% of a segment) defects on the scan. Final diagnosis was confirmed by pulmonary angiography (16), thoracentesis (40), venography (11), other radiographic and laboratory studies, and clinical course. Of the 53 patients, only 2 patients had venous thrombotic disease. One patient had PE on pulmonary angiography, the other patient had thrombophlebitis on venography. The remainder of the patients had effusions due to congestive heart failure (12), malignancy (12), infection (7), trauma (7), collegen vascular disease (7), sympathetic effusion (3) and unknown etiology (3). The authors conclude that lung scans with significant perfusion defects limited to matching pleural effusions on chest x-ray have a low probability for PE

  19. Pulmonary embolism: Prospective comparison of spiral CT with ventilation - perfusion scintigraphy

    International Nuclear Information System (INIS)

    Mayo Jhon R; Remi Jardin, Martine; Muller Mestor I

    1999-01-01

    The pulmonary thromboembolism (PTE) it is an entity common with great morbidity and mortality that it requires a diagnosis soon and specify. Commonly the ventilation gammagraphy - perfusion has been the used exam of first more frequent line when one suspects the PTE but unfortunately a great quantity of reports is called of intermediate probability, for what requires complementary studies, to confirm or to discard the diagnosis. A prospective study was made with 142 patients that had suspicion of TEP in the hospital of Vancouver (Canada) and in the hospital of Calmette (France), being carried out in all gammagraphy of ventilation-perfusion and helical CT, being only taken to lung angiography to those that not had high clinical suspicion of TEP with gammagraphy or helical CT very suggestive or tuneless, undergoing the results valuation for different observers

  20. Simultaneous Multiagent Hyperpolarized 13C Perfusion Imaging

    DEFF Research Database (Denmark)

    von Morze, Cornelius; Bok, Robert A.; Reed, Galen D.

    2014-01-01

    in simulations. "Tripolarized" perfusion MRI methods were applied to initial preclinical studies with differential conditions of vascular permeability, in normal mouse tissues and advanced transgenic mouse prostate tumors. Results: Dynamic imaging revealed clear differences among the individual tracer...... distributions. Computed permeability maps demonstrated differential permeability of brain tissue among the tracers, and tumor perfusion and permeability were both elevated over values expected for normal tissues. Conclusion: Tripolarized perfusion MRI provides new molecular imaging measures for specifically...

  1. Regional distribution of ventilation and perfusion in patients with obstructive pulmonary disease and alpha/sub 1/-antitrypsin deficiency

    Energy Technology Data Exchange (ETDEWEB)

    Mostafa, A B.M.G.; Tulley, N J; Harding, L K; Stockley, R A

    1983-08-01

    Regional distribution of pulmonary ventilation and perfusion has been determined of 13 patients with chronic obstructive pulmonary disease (COPD). Eight patients had alpha/sub 1/-antitrypsin deficiency (..cap alpha../sub 1/ATD). Ventilation studies were carried out using xenon-133 (/sup 133/Xe) and krypton-81m (sup(81m)Kr) gases. Trapping indices were determined from the wash-out part of the xenon ventilation studies. Results obtained from patients were compared with those of normal controls. Ventilation studies with sup(81m)Kr showed pulmonary changes more clearly than did /sup 133/Xe studies and the trapping of radio-xenon was more extensive in lung bases than in apices whether or not the patients had ..cap alpha../sub 1/ ATD. The distribution of perfusion followed a pattern similar to that of ventilation, but did not differ statistically from that of the normal controls.

  2. Computed Tomography Perfusion Imaging for the Diagnosis of Hepatic Alveolar Echinococcosis

    Science.gov (United States)

    Sade, Recep; Kantarci, Mecit; Genc, Berhan; Ogul, Hayri; Gundogdu, Betul; Yilmaz, Omer

    2018-01-01

    Objective: Alveolar echinococcosis (AE) is a rare life-threatening parasitic infection. Computed tomography perfusion (CTP) imaging has the potential to provide both quantitative and qualitative information about the tissue perfusion characteristics. The purpose of this study was the examination of the characteristic features and feasibility of CTP in AE liver lesions. Material and Methods: CTP scanning was performed in 25 patients who had a total of 35 lesions identified as AE of the liver. Blood flow (BF), blood volume (BV), portal venous perfusion (PVP), arterial liver perfusion (ALP), and hepatic perfusion indexes (HPI) were computed for background liver parenchyma and each AE lesion. Results: Significant differences were detected between perfusion values of the AE lesions and background liver tissue. The BV, BF, ALP, and PVP values for all components of the AE liver lesions were significantly lower than the normal liver parenchyma (p<0.01). Conclusions: We suggest that perfusion imaging can be used in AE of the liver. Thus, the quantitative knowledge of perfusion parameters are obtained via CT perfusion imaging. PMID:29531482

  3. Molecular imaging of the human pulmonary vascular endothelium in pulmonary hypertension: a phase II safety and proof of principle trial

    Energy Technology Data Exchange (ETDEWEB)

    Harel, Francois [Montreal Heart Institute, Research Center, Montreal, QC (Canada); Universite de Montreal, Department of Nuclear Medicine, Montreal, Quebec (Canada); Langleben, David; Abikhzer, Gad [McGill University, Lady Davis Institute and Jewish General Hospital, Montreal, Quebec (Canada); Provencher, Steve; Guimond, Jean [Institut Universitaire de Cardiologie et de Pneumologie de Quebec, Quebec (Canada); Fournier, Alain; Letourneau, Myriam [INRS-Institut Armand-Frappier, Laval, Quebec (Canada); Finnerty, Vincent; Nguyen, Quang T.; Levac, Xavier [Montreal Heart Institute, Research Center, Montreal, QC (Canada); Mansour, Asmaa; Guertin, Marie-Claude [Montreal Health Innovation Coordination Center, Montreal, QC (Canada); Dupuis, Jocelyn [Montreal Heart Institute, Research Center, Montreal, QC (Canada); Universite de Montreal, Department of Medicine, Montreal, Quebec (Canada)

    2017-07-15

    The adrenomedullin receptor is densely expressed in the pulmonary vascular endothelium. PulmoBind, an adrenomedullin receptor ligand, was developed for molecular diagnosis of pulmonary vascular disease. We evaluated the safety of PulmoBind SPECT imaging and its capacity to detect pulmonary vascular disease associated with pulmonary hypertension (PH) in a human phase II study. Thirty patients with pulmonary arterial hypertension (PAH, n = 23) or chronic thromboembolic PH (CTEPH, n = 7) in WHO functional class II (n = 26) or III (n = 4) were compared to 15 healthy controls. Lung SPECT was performed after injection of 15 mCi {sup 99m}Tc-PulmoBind in supine position. Qualitative and semi-quantitative analyses of lung uptake were performed. Reproducibility of repeated testing was evaluated in controls after 1 month. PulmoBind injection was well tolerated without any serious adverse event. Imaging was markedly abnormal in PH with ∝50% of subjects showing moderate to severe heterogeneity of moderate to severe extent. The abnormalities were unevenly distributed between the right and left lungs as well as within each lung. Segmental defects compatible with pulmonary embolism were present in 7/7 subjects with CTEPH and in 2/23 subjects with PAH. There were no segmental defects in controls. The PulmoBind activity distribution index, a parameter indicative of heterogeneity, was elevated in PH (65% ± 28%) vs. controls (41% ± 13%, p = 0.0003). In the only subject with vasodilator-responsive idiopathic PAH, PulmoBind lung SPECT was completely normal. Repeated testing 1 month later in healthy controls was well tolerated and showed no significant variability of PulmoBind distribution. In this phase II study, molecular SPECT imaging of the pulmonary vascular endothelium using {sup 99m}Tc-PulmoBind was safe. PulmoBind showed potential to detect both pulmonary embolism and abnormalities indicative of pulmonary vascular disease in PAH. Phase III studies with this novel tracer and

  4. Thallium-201 myocardial imaging in young adults with anomalous left coronary artery arising from the pulmonary artery

    International Nuclear Information System (INIS)

    Moodie, D.S.; Cook, S.A.; Gill, C.C.; Napoli, C.A.

    1980-01-01

    Anomalous origin of the left coronary artery from the pulmonary artery (Bland-Garland-White syndrome) may produce myocardial ischemia, infarction, and frequently death in infancy. Some patients, however, develop satisfactory coronary artery collaterals and are relatively asymptomatic into adulthood. Very little is known about their myocardial perfusion patterns. We studied three young adults with this condition using stress thallium-201 myocardial imaging. Electrocardiograms in two patients demonstrated old arterolateral myocardial infarctions. Preoperative stress exercise tests were positive in all three patients. Marked perfusion abnormalities were found in the proximal anterolateral wall in all patients, and one patient also had a posterolateral defect. Postoperatively, all stress tests returned to normal. Thallium imaging demonstrated improvement in ischemic areas, but old scars persisted

  5. Multimodality imaging of pulmonary infarction

    International Nuclear Information System (INIS)

    Bray, T.J.P.; Mortensen, K.H.; Gopalan, D.

    2014-01-01

    Highlights: • A plethora of pulmonary and systemic disorders, often associated with grave outcomes, may cause pulmonary infarction. • A stereotypical infarct is a peripheral wedge shaped pleurally based opacity but imaging findings can be highly variable. • Multimodality imaging is key to diagnosing the presence, aetiology and complications of pulmonary infarction. • Multimodality imaging of pulmonary infarction together with any ancillary features often guide to early targeted treatment. • CT remains the principal imaging modality with MRI increasingly used alongside nuclear medicine studies and ultrasound. - Abstract: The impact of absent pulmonary arterial and venous flow on the pulmonary parenchyma depends on a host of factors. These include location of the occlusive insult, the speed at which the occlusion develops and the ability of the normal dual arterial supply to compensate through increased bronchial arterial flow. Pulmonary infarction occurs when oxygenation is cut off secondary to sudden occlusion with lack of recruitment of the dual supply arterial system. Thromboembolic disease is the commonest cause of such an insult but a whole range of disease processes intrinsic and extrinsic to the pulmonary arterial and venous lumen may also result in infarcts. Recognition of the presence of infarction can be challenging as imaging manifestations often differ from the classically described wedge shaped defect and a number of weighty causes need consideration. This review highlights aetiologies and imaging appearances of pulmonary infarction, utilising cases to illustrate the essential role of a multimodality imaging approach in order to arrive at the appropriate diagnosis

  6. Multimodality imaging of pulmonary infarction

    Energy Technology Data Exchange (ETDEWEB)

    Bray, T.J.P., E-mail: timothyjpbray@gmail.com [Department of Radiology, Papworth Hospital NHS Foundation Trust, Ermine Street, Papworth Everard, Cambridge CB23 3RE (United Kingdom); Mortensen, K.H., E-mail: mortensen@doctors.org.uk [Department of Radiology, Papworth Hospital NHS Foundation Trust, Ermine Street, Papworth Everard, Cambridge CB23 3RE (United Kingdom); University Department of Radiology, Addenbrookes Hospital, Cambridge University Hospitals NHS Foundation Trust, Hills Road, Box 318, Cambridge CB2 0QQ (United Kingdom); Gopalan, D., E-mail: deepa.gopalan@btopenworld.com [Department of Radiology, Papworth Hospital NHS Foundation Trust, Ermine Street, Papworth Everard, Cambridge CB23 3RE (United Kingdom)

    2014-12-15

    Highlights: • A plethora of pulmonary and systemic disorders, often associated with grave outcomes, may cause pulmonary infarction. • A stereotypical infarct is a peripheral wedge shaped pleurally based opacity but imaging findings can be highly variable. • Multimodality imaging is key to diagnosing the presence, aetiology and complications of pulmonary infarction. • Multimodality imaging of pulmonary infarction together with any ancillary features often guide to early targeted treatment. • CT remains the principal imaging modality with MRI increasingly used alongside nuclear medicine studies and ultrasound. - Abstract: The impact of absent pulmonary arterial and venous flow on the pulmonary parenchyma depends on a host of factors. These include location of the occlusive insult, the speed at which the occlusion develops and the ability of the normal dual arterial supply to compensate through increased bronchial arterial flow. Pulmonary infarction occurs when oxygenation is cut off secondary to sudden occlusion with lack of recruitment of the dual supply arterial system. Thromboembolic disease is the commonest cause of such an insult but a whole range of disease processes intrinsic and extrinsic to the pulmonary arterial and venous lumen may also result in infarcts. Recognition of the presence of infarction can be challenging as imaging manifestations often differ from the classically described wedge shaped defect and a number of weighty causes need consideration. This review highlights aetiologies and imaging appearances of pulmonary infarction, utilising cases to illustrate the essential role of a multimodality imaging approach in order to arrive at the appropriate diagnosis.

  7. Counting the mismatches - lung ventilation/perfusion subtraction index

    International Nuclear Information System (INIS)

    Anderson, T.C.; Evans, S.G.; Larcos, G.; Farlow, D.C.

    1998-01-01

    Full text: There is potential for interobserver variability in interpretation of ventilation/perfusion (V/Q) scans. Objective quantification of V/Q mismatch could be useful. Thus, the aim of this study is to determine the validity of image subtraction in a group of 27 patients (11 men, 8 women; mean age 59.4 years [range 21-81 years])investigated by V/Q scans for suspected pulmonary emboli. A standard 6 view V/Q scan was obtained with two cobalt markers used on the anterior and posterior surfaces for image alignment. Ventilation images were normalised to the perfusion using an area of normal ventilation and perfusion. With the use of automated, and if required, manual alignment, perfusion images were subtracted from ventilation, with a median filter applied. A summed index of mismatch for each lung scan was calculated from the difference. This index was then retrospectively compared to the result reported by one of four experienced physicians. Two patients with chronic obstructive airways disease were excluded from analysis. We conclude that high probability V/Q scans can be differentiated from low probability studies using this index; further prospective investigation in a larger cohort is warranted

  8. Serial lung imaging with 123I-IMP in localized pulmonary lesions

    International Nuclear Information System (INIS)

    Nakajo, Masayuki; Shimada, Jurio; Shimozono, Michiko; Uchiyama, Noriaki; Hiraki, Yoshiyuki; Shinohara, Shinji.

    1988-01-01

    123 I-IMP (N-isopropyl-p-[ 123 I]-iodoamphetamine) dynamic (1 frame/min for 25 mins), 30-min and 4-hr static lung imaging was performed in a total of 65 patients with roentgenographic evidence of localized pulmonary lesion (12 with pneumonia, one with lung abscess, 5 with pulmonary tuberculosis, 3 with pneumoconiosis, one with lung fluke disease and 43 with various histological types of primary lung cancer). The findings in 65 of 70 (95 %) lesions in the initial 1 or 2-min dynamic 123 I-IMP images were analogous to those obtained by 99m Tc-MAA lung perfusion imaging and decreased activity was observed in 68 of 70 (97 %) lesions, suggesting that the initial images mainly reflected the relative distribution of pulmonary arterial blood flow. However, 123 I-IMP accumulated differently according to the pathological conditions afterwards. Decrease activity from 123 I-IMP was contineously observed in a cavity of the lung abscess, 2 of 2 tuberculomas, 3 of 7 large nodules of pneumoconiosis and all of the 42 cancerous lesions which were possible to be evaluated. Gradual increased in activity relative to that of ''normal lung fields'' was observed in all 14 lesions of pneumonia; pneumonic lesions of the lung abscess, tuberculosis and lung fluke disease; 4 of 7 large nodules of pneumoconiosis; all of 8 atelectatic lesions and 32 of 44 areas surrounding cancers (most of them had roentgenographic evidence of infiltrating shadows). Thus 123 I-IMP accumulated increasingly in pneumonic and atelectatic lesions, while it appeared not to accumulate in such lesions replacing lung tissues as cavity, caseous and fibrous lesions and primary lung cancers. 123 I-IMP can be used as a new lung imaging agent to provide diagnostic informations on the property of pulmonary lesions. (author)

  9. Ventilation and perfusion display in a single image

    International Nuclear Information System (INIS)

    Lima, J.J.P. de; Botelho, M.F.R.; Pereira, A.M.S.; Rafael, J.A.S.; Pinto, A.J.; Marques, M.A.T.; Pereira, M.C.; Baganha, M.F.; Godinho, F.

    1991-01-01

    A new method of ventilation and perfusion display onto a single image is presented. From the data on regions of interest of the lungs, three-dimensional histograms are created, containing as parameters X and Y for the position of the pixels, Z for the perfusion and colour for local ventilation. The perfusion value is supplied by sets of curves having Z proportional to the local perfusion count rate. Ventilation modulates colour. Four perspective views of the histogram are simultaneously displayed to allow visualization of the entire organ. Information about the normal ranges for both ventilation and perfusion is also provided in the histograms. (orig.)

  10. Dynamic CT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Caruso, Damiano; Eid, Marwen; Schoepf, U. Joseph; Jin, Kwang Nam; Varga-Szemes, Akos; Tesche, Christian; Mangold, Stefanie

    2016-01-01

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  11. Dynamic CT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncological and Pathological Sciences, University of Rome “Sapienza”, Latina (Italy); Eid, Marwen [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Mangold, Stefanie [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen (Germany); and others

    2016-10-15

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  12. Pulmonary hypertension CT imaging

    International Nuclear Information System (INIS)

    Nedevska, A.

    2013-01-01

    Full text: The right heart catheterization is the gold standard in the diagnosis and determines the severity of pulmonary hypertension. The significant technical progress of noninvasive diagnostic imaging methods significantly improves the pixel density and spatial resolution in the study of cardiovascular structures, thus changes their role and place in the overall diagnostic plan. Learning points: What is the etiology, clinical manifestation and general pathophysiological disorders in pulmonary hypertension. What are the established diagnostic methods in the diagnosis and follow-up of patients with pulmonary hypertension. What is the recommended protocol for CT scanning for patients with clinically suspected or documented pulmonary hypertension. What are the important diagnostic findings in CT scan of a patient with pulmonary hypertension. Discussion: The prospect of instantaneous complex - anatomical and functional cardiopulmonary and vascular diagnostics seems extremely attractive. The contrast enhanced multislice computed (CT ) and magnetic resonance imaging are very suitable methods for imaging the structures of the right heart, with the possibility of obtaining multiple projections and three-dimensional imaging reconstructions . There are specific morphological features that, if carefully analyzed, provide diagnostic information. Thus, it is possible to avoid or at least reduce the frequency of use of invasive diagnostic cardiac catheterization in patients with pulmonary hypertension. Conclusion: This review focuses on the use of contrast-enhanced CT for comprehensive evaluation of patients with pulmonary hypertension and presents the observed characteristic changes in the chest, lung parenchyma , the structures of the right half of the heart and pulmonary vessels

  13. Fractal analysis in radiological and nuclear medicine perfusion imaging: a systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Michallek, Florian; Dewey, Marc [Humboldt-Universitaet zu Berlin, Freie Universitaet Berlin, Charite - Universitaetsmedizin Berlin, Medical School, Department of Radiology, Berlin (Germany)

    2014-01-15

    To provide an overview of recent research in fractal analysis of tissue perfusion imaging, using standard radiological and nuclear medicine imaging techniques including computed tomography (CT), magnetic resonance imaging (MRI), ultrasound, positron emission tomography (PET) and single-photon emission computed tomography (SPECT) and to discuss implications for different fields of application. A systematic review of fractal analysis for tissue perfusion imaging was performed by searching the databases MEDLINE (via PubMed), EMBASE (via Ovid) and ISI Web of Science. Thirty-seven eligible studies were identified. Fractal analysis was performed on perfusion imaging of tumours, lung, myocardium, kidney, skeletal muscle and cerebral diseases. Clinically, different aspects of tumour perfusion and cerebral diseases were successfully evaluated including detection and classification. In physiological settings, it was shown that perfusion under different conditions and in various organs can be properly described using fractal analysis. Fractal analysis is a suitable method for quantifying heterogeneity from radiological and nuclear medicine perfusion images under a variety of conditions and in different organs. Further research is required to exploit physiologically proven fractal behaviour in the clinical setting. (orig.)

  14. Fractal analysis in radiological and nuclear medicine perfusion imaging: a systematic review

    International Nuclear Information System (INIS)

    Michallek, Florian; Dewey, Marc

    2014-01-01

    To provide an overview of recent research in fractal analysis of tissue perfusion imaging, using standard radiological and nuclear medicine imaging techniques including computed tomography (CT), magnetic resonance imaging (MRI), ultrasound, positron emission tomography (PET) and single-photon emission computed tomography (SPECT) and to discuss implications for different fields of application. A systematic review of fractal analysis for tissue perfusion imaging was performed by searching the databases MEDLINE (via PubMed), EMBASE (via Ovid) and ISI Web of Science. Thirty-seven eligible studies were identified. Fractal analysis was performed on perfusion imaging of tumours, lung, myocardium, kidney, skeletal muscle and cerebral diseases. Clinically, different aspects of tumour perfusion and cerebral diseases were successfully evaluated including detection and classification. In physiological settings, it was shown that perfusion under different conditions and in various organs can be properly described using fractal analysis. Fractal analysis is a suitable method for quantifying heterogeneity from radiological and nuclear medicine perfusion images under a variety of conditions and in different organs. Further research is required to exploit physiologically proven fractal behaviour in the clinical setting. (orig.)

  15. Hepatic artery perfusion imaging

    International Nuclear Information System (INIS)

    Thrall, J.H.; Gyves, J.W.; Ziessman, H.A.; Ensminger, W.D.

    1985-01-01

    Organ and region-selective intra-arterial chemotherapy have been used for more than two decades to treat malignant neoplasms in the extremities, head and neck region, pelvis, liver, and other areas. Substantial evidence of improved response to regional chemotherapy now exists, but there are stringent requirements for successful application of the regional technique. First, the chemotherapeutic agent employed must have appropriate pharmacokinetic and pharmacodynamic properties. Second, the drug must be reliably delivered to the tumor-bearing area. This typically requires an arteriographic assessment of the vascular supply of the tumor, followed by placement of a therapeutic catheter and confirmation that the ''watershed'' perfusion distribution from the catheter truly encompasses the tumor. Optimal catheter placement also minimizes perfusion of nontarget organs. Radionuclide perfusion imaging with technetium 99m-labeled particles, either microspheres or macroaggregates of albumin, has become the method of choice for making these assessments. Catheter placement itself is considered by many to represent a type of ''therapeutic'' intervention. However, once the catheter is in the hepatic artery the radionuclide perfusion technique can be used to assess adjunctive pharmacologic maneuvers designed to further exploit the regional approach to chemotherapy. This chapter presents the technetium Tc 99m macroaggregated albumin method for assessing catheter placement and the pharmacokinetic rationale for regional chemotherapy, and discusses two promising avenues for further intervention

  16. Usefulness of perfusion MR imaging in hyperacute ischemic stroke

    International Nuclear Information System (INIS)

    Park, Ji Hoon; Kim, Jae Hyoung; Shin, Tae Min; Lee, Eun Ja; Chung, Sung Hoon; Choi, Nack Cheon; Lim, Byeong Hoon; Kim, In One

    1998-01-01

    Perfusion MR imaging is a new technique for the assessment of acute ischemic stroke. The aim of this study was to evaluate the usefulness of this imaging in hyperacute ischemic stroke in comparison with conventional CT and MR imaging. Eight patients presenting the symptoms of acute ischemic stroke due to middle cerebral artery occlusion were included in this study. Within 2 hours of initial CT scan and 6 hours after the onset of stroke, perfusion MR imaging was performed in all patients using a single-section dynamic contrast-enhanced T2*-weighted imager in conjunction with conventional routine MR imaging and MR angiography. Cerebral blood volume (CBV) maps were then obtained from dynamic MR imaging data by using numerical integration techniques. The findings of CBV maps were compared with those of initial and follow-up CT or MR images. The findings of CBV maps were obviously abnormal in all patients, as compared with normal or focal subtle abnormal findings seen on initial CT and MR images. CBV in the occluded arterial territory was lower in all eight patients;two had focal regions of increased CBV within the affected territory, indicating reperfusion hyperemia. In all patients, regions of abnormal CBV were eventually converted to infarctions on follow-up images. Perfusion MR imaging was useful for the evaluation of hemodynamic change occurring during cerebral perfusion in hyperacute ischemic stroke, and prediction of the final extent of infarction. These results suggest that pertusion MR imaging can play an important role in the diagnosis and management of hyperacute ischemic stroke.=20

  17. Intravoxel incoherent motion perfusion imaging in acute stroke: initial clinical experience

    International Nuclear Information System (INIS)

    Federau, C.; Becce, F.; Maeder, P.; Meuli, R.; Sumer, S.; Wintermark, M.; O'Brien, K.

    2014-01-01

    Intravoxel incoherent motion (IVIM) imaging is an MRI perfusion technique that uses a diffusion-weighted sequence with multiple b values and a bi-compartmental signal model to measure the so-called pseudo-diffusion of blood caused by its passage through the microvascular network. The goal of the current study was to assess the feasibility of IVIM perfusion fraction imaging in patients with acute stroke. Images were collected in 17 patients with acute stroke. Exclusion criteria were onset of symptoms to imaging >5 days, hemorrhagic transformation, infratentorial lesions, small lesions 2 . Image quality was assessed by two radiologists, and quantitative analysis was performed in regions of interest placed in the stroke area, defined by thresholding the apparent diffusion coefficient maps, as well as in the contralateral region. IVIM perfusion fraction maps showed an area of decreased perfusion fraction f in the region of decreased apparent diffusion coefficient. Quantitative analysis showed a statistically significant decrease in both IVIM perfusion fraction f (0.026 ± 0.019 vs. 0.056 ± 0.025, p = 2.2 . 10 -6 ) and diffusion coefficient D compared with the contralateral side (3.9 ± 0.79 . 10 -4 vs. 7.5 ± 0.86 . 10 -4 mm 2 /s, p = 1.3 . 10 -20 ). IVIM perfusion fraction imaging is feasible in acute stroke. IVIM perfusion fraction is significantly reduced in the visible infarct. Further studies should evaluate the potential for IVIM to predict clinical outcome and treatment response. (orig.)

  18. Relative preservation of peripheral lung function in smoking-related pulmonary emphysema: assessment with 99mTc-MAA perfusion and dynamic 133Xe SPET

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Kume, Norihiko; Matsunaga, Naofumi; Ogasawara, Nobuhiko; Motoyama, Kazumi; Hara, Akiko; Matsumoto, Tsuneo

    2000-01-01

    In this study the cross-sectional functional differences between the central and peripheral lung in smokers with pulmonary emphysema were evaluated by lung perfusion and dynamic xenon-133 single-photon emission tomography (SPET). The subjects were 81 patients with a long-term smoking history and relatively advanced emphysema, 17 non-smoker patients with non-obstructive lung diseases and six healthy non-smokers. Regional lung functional difference between the peripheral and central lung was assessed in the upper, middle and lower lung zones by technetium-99m macroaggregated albumin SPET and dynamic 133 Xe SPET. The distribution of emphysematous changes was assessed by density-mask computed tomography (CT) images which depicted abnormally low attenuation areas (LAAs) of less than -960 Hounsfield units. Two hundred and eighty-eight (59.2%) lung zones of 63 (77.7%) patients with pulmonary emphysema showed relative preservation of lung function in the peripheral lung, with a curvilinear band of normal perfusion (a stripe sign) and a significantly faster 133 Xe half-clearance time (T 1/2 ) than in central lung (P 1/2 in the peripheral lung area (P 1/2 values and LAA distributions between the central and peripheral lung. Relative preservation of peripheral lung function seems to be a characteristic feature in smoking-related pulmonary emphysema, and may indicate a lower susceptibility of peripheral parenchyma to the development of this disease. (orig.)

  19. Fuzzy modeling of electrical impedance tomography images of the lungs

    International Nuclear Information System (INIS)

    Tanaka, Harki; Ortega, Neli Regina Siqueira; Galizia, Mauricio Stanzione; Borges, Joao Batista; Amato, Marcelo Britto Passos

    2008-01-01

    Objectives: Aiming to improve the anatomical resolution of electrical impedance tomography images, we developed a fuzzy model based on electrical impedance tomography's high temporal resolution and on the functional pulmonary signals of perfusion and ventilation. Introduction: Electrical impedance tomography images carry information about both ventilation and perfusion. However, these images are difficult to interpret because of insufficient anatomical resolution, such that it becomes almost impossible to distinguish the heart from the lungs. Methods: Electrical impedance tomography data from an experimental animal model were collected during normal ventilation and apnoea while an injection of hypertonic saline was administered. The fuzzy model was elaborated in three parts: a modeling of the heart, the pulmonary ventilation map and the pulmonary perfusion map. Image segmentation was performed using a threshold method, and a ventilation/perfusion map was generated. Results: Electrical impedance tomography images treated by the fuzzy model were compared with the hypertonic saline injection method and computed tomography scan images, presenting good results. The average accuracy index was 0.80 when comparing the fuzzy modeled lung maps and the computed tomography scan lung mask. The average ROC curve area comparing a saline injection image and a fuzzy modeled pulmonary perfusion image was 0.77. Discussion: The innovative aspects of our work are the use of temporal information for the delineation of the heart structure and the use of two pulmonary functions for lung structure delineation. However, robustness of the method should be tested for the imaging of abnormal lung conditions. Conclusions: These results showed the adequacy of the fuzzy approach in treating the anatomical resolution uncertainties in electrical impedance tomography images. (author)

  20. Magnetic Resonance Imaging of Ventilation and Perfusion in the Lung

    Science.gov (United States)

    Prisk, Gordon Kim (Inventor); Hopkins, Susan Roberta (Inventor); Buxton, Richard Bruce (Inventor); Pereira De Sa, Rui Carlos (Inventor); Theilmann, Rebecca Jean (Inventor); Cronin, Matthew Vincent (Inventor)

    2017-01-01

    Methods, devices, and systems are disclosed for implementing a fully quantitative non-injectable contrast proton MRI technique to measure spatial ventilation-perfusion (VA/Q) matching and spatial distribution of ventilation and perfusion. In one aspect, a method using MRI to characterize ventilation and perfusion in a lung includes acquiring an MR image of the lung having MR data in a voxel and obtaining a breathing frequency parameter, determining a water density value, a specific ventilation value, and a perfusion value in at least one voxel of the MR image based on the MR data and using the water density value to determine an air content value, and determining a ventilation-perfusion ratio value that is the product of the specific ventilation value, the air content value, the inverse of the perfusion value, and the breathing frequency.

  1. Parallel imaging for first-pass myocardial perfusion

    NARCIS (Netherlands)

    Irwan, Roy; Lubbers, Daniel D.; van der Vleuten, Pieter A.; Kappert, Peter; Gotte, Marco J. W.; Sijens, Paul E.

    Two parallel imaging methods used for first-pass myocardial perfusion imaging were compared in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image artifacts. One used adaptive Time-adaptive SENSitivity Encoding (TSENSE) and the other used GeneRalized Autocalibrating

  2. Perfusion lung scintigraphy in primary broncho-pulmonary cancer

    International Nuclear Information System (INIS)

    Lapergue, Paul.

    1976-01-01

    Research on primary broncho-pulmonary cancer has called extensively on scintigraphy and it seemed interesting to weigh up the pros and cons of the technique in this particular case. Our intention is to sum up objectively from recent documents the applications of scintigraphy in the study of primary broncho-pulmonary cancers and to attempt, on the basis of the results compiled, to show what benefits have been gained from this technique and to find out whether it has any pre-surgical value and of what kind. The technique was invariable; the tracer consists of human albumin macro-aggregates labelled with technetium 99m which by its short half-life and slight penetration enables four exposures to be taken during the same examination (front, back, right and left profiles), thus reducing the risks of mistaken diagnoses due to the use of a single incidence. Similarly the detection method was always the scintillation camera which explores the whole organ at once, considerably shortening the examination time. Lung scintigraphy by perfusion of labelled human albumin macro-aggregates offers the great advantage of being simple to use and harmless. It is easy to understand the important place it has taken in the range of methods available for lung circulation exploration [fr

  3. Myocardial first pass perfusion imaging with gadobutrol: impact of parallel imaging algorithms on image quality and signal behavior.

    Science.gov (United States)

    Theisen, Daniel; Wintersperger, Bernd J; Huber, Armin; Dietrich, Olaf; Reiser, Maximilian F; Schönberg, Stefan O

    2007-07-01

    To implement parallel imaging algorithms in fast gradient recalled echo sequences for myocardial perfusion imaging and evaluate image quality, signal-to-noise ratio (SNR), contrast-enhancement ratio (CER), and semiquantitative perfusion parameters. In 20 volunteers, myocardial perfusion imaging with gadobutrol was performed at rest using an accelerated TurboFLASH sequence (TR 2.3 milliseconds, TE 0.93 milliseconds, flip angle [FA] 15 degrees) with GRAPPA, R=2. A nonaccelerated TurboFLASH sequence with similar scan parameters served as standard of reference. Artifacts were assessed qualitatively. SNR, CER, and CNR were calculated and semiquantitative perfusion parameters were determined from fitted SI-time curves. Phantom measurements yielded significant higher SNR for nonaccelerated images (Pimages (Pimages for artifacts by 2 board-certified radiologists yielded a significant reduction in dark rim artifacts with GRAPPA, R=2 (P<0.001). The application of GRAPPA with an acceleration factor of R=2 leads to a significant reduction of dark rim artifacts in fast gradient recalled echo sequences.

  4. Estimation of pulmonary hypertension by perfusion lung scintigraphy: Gravitational effect of postural changes between the lateral decubitus positions

    International Nuclear Information System (INIS)

    Tanaka, Masao; Fujii, Tadashige; Hirayama, Jiro; Okubo, Shinichi; Sekiguchi, Morie

    1990-01-01

    To estimate pulmonary hypertension in patients with various heart diseases, we devised a new method using perfusion lung scintigraphy with 99m Tc-labelled macroaggregated albumin. In this method, changes in the distribution of pulmonary perfusion caused by gravitational effects, namely, changes in the total count ratios of the right lung against the left lung between right and left lateral decubitus positions (rt/lt), were assessed in 62 patients and in 10 normal subjects. The rt/lt ratios were calculated as indices of the above changes. They correlated significantly with mean pulmonary arterial pressure (mPAP) (γ=-0.62, P<0.001), pulmonary capillary wedge pressure (γ=-0.63, P<0.001) and pulmonary arteriolar resistance (γ=0.50, P<0.001) in all subjects. In 17 patients with valvular heart diseases, the ratio correlated significantly with mPAP (γ=-0.84, P<0.001). In 10 patients with various heart diseases, the U/S ratio, i.e. the index of changes in the count ratios of the upper field against the lower field for the right lung following postural change from the uprigth to the supine position, was also obtained as well as the rt/lt ratio. The latter evidenced a better correlation with mPAP (γ=-0.90, P<0.001) than the former (γ=-0.64, P<0.05). We conclude that this method is valuable as a noninvasive approach for the estimation of pulmonary hypertension. (orig.)

  5. Whole-brain dynamic CT angiography and perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Orrison, W.W. [CHW Nevada Imaging Company, Nevada Imaging Centers, Spring Valley, Las Vegas, NV (United States); College of Osteopathic Medicine, Touro University Nevada, Henderson, NV (United States); Department of Health Physics and Diagnostic Sciences, University of Nevada Las Vegas, Las Vegas, NV (United States); Department of Medical Education, University of Nevada School of Medicine, Reno, NV (United States); Snyder, K.V.; Hopkins, L.N. [Department of Neurosurgery, Millard Fillmore Gates Circle Hospital, Buffalo, NY (United States); Roach, C.J. [School of Life Sciences, University of Nevada Las Vegas, Las Vegas, NV (United States); Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States); Ringdahl, E.N. [Department of Psychology, University of Nevada Las Vegas, Las Vegas, NV (United States); Nazir, R. [Shifa International Hospital, Islamabad (Pakistan); Hanson, E.H., E-mail: eric.hanson@amigenics.co [College of Osteopathic Medicine, Touro University Nevada, Henderson, NV (United States); Department of Health Physics and Diagnostic Sciences, University of Nevada Las Vegas, Las Vegas, NV (United States); Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States)

    2011-06-15

    The availability of whole brain computed tomography (CT) perfusion has expanded the opportunities for analysing the haemodynamic parameters associated with varied neurological conditions. Examples demonstrating the clinical utility of whole-brain CT perfusion imaging in selected acute and chronic ischaemic arterial neurovascular conditions are presented. Whole-brain CT perfusion enables the detection and focused haemodynamic analyses of acute and chronic arterial conditions in the central nervous system without the limitation of partial anatomical coverage of the brain.

  6. Magnetic resonance myocardial perfusion imaging-First experience at 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Klumpp, B. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: bernhard.klumpp@med.uni-tuebingen.de; Hoevelborn, T. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Cardiology, Otfried-Mueller-Str. 10, 72076 Tuebingen (Germany)], E-mail: tobias.hoevelborn@gmx.de; Fenchel, M. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: michael.fenchel@med.uni-tuebingen.de; Stauder, N.I. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: norbert.stauder@stgag.ch; Kramer, U. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: ulrich.kramer@med.uni-tuebingen.de; May, A. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Cardiology, Otfried-Mueller-Str. 10, 72076 Tuebingen (Germany)], E-mail: andreas.may@med.uni-tuebingen.de; Gawaz, M.P. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Cardiology, Otfried-Mueller-Str. 10, 72076 Tuebingen (Germany)], E-mail: meinrad.gawaz@med.uni-tuebingen.de; Claussen, C.D. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: claus.claussen@med.uni-tuebingen.de; Miller, S. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: stephan.miller@med.uni-tuebingen.de

    2009-01-15

    Objective: MR myocardial perfusion imaging (MRMPI) is an established technique for the evaluation of the hemodynamical relevance of coronary artery disease. Perfusion imaging at 3.0 T provides certain advantages compared to 1.5 T. Aim of this study was to evaluate myocardial MR perfusion imaging at 3.0 T. Materials and methods: Twelve patients with stable Angina pectoris and known or suspected coronary artery disease were examined at 3.0 T. Myocardial perfusion was assessed using a saturation recovery gradient echo 2D sequence (TR 1.9 ms, TE 1.0 ms, FA 12 deg.) with 0.05 mmol Gd-DTPA per kg body weight at stress during injection of 140 {mu}g adenosine/kg body weight/min and at rest in short axis orientation. Perfusion analysis was based on a least square fit of the signal/time curve (peak signal intensity, slope). Perfusion series were assessed by two independent observers. Reference for the presence of relevant coronary artery stenoses was invasive coronary angiography. Two experienced observers evaluated the coronary angiograms in biplane projections for the presence and grade of stenoses. Results were compared with the MR perfusion analysis. Results: All MR examinations could be safely performed and yielded high image quality. In eight patients stress-induced hypoperfusion was detected (stenosis >70% in coronary angiography). In four patients myocardial hypoperfusion was ruled out (stenosis <70%). The myocardial perfusion reserve index was significantly reduced in hypoperfused myocardium with 1.9 {+-} 1.6 compared to 2.5 {+-} 1.6 in regularly perfused myocardium (p < 0.05). In coronary angiography, eight patients were found to suffer from coronary artery disease, whereas in four patients coronary artery disease was ruled out. Conclusion: Our initial results show that MRMPI at 3.0 T provides reliably high-image quality and diagnostic accuracy.

  7. The preliminary study of CT cerebral perfusion imaging in transient ischemic attacks

    International Nuclear Information System (INIS)

    Lu Jie; Li Kuncheng; Du Xiangying

    2002-01-01

    Objective: To probe the application of CT cerebral perfusion imaging on transient ischemic attacks (TIA). Methods: Conventional CT and CT cerebral perfusion imaging were performed on 5 normal adults and 20 patients with clinically diagnosed TIA. After regular CT examination, dynamic scans of 40 seconds were performed on selected slice (usually on the basal ganglia slice), while 40 ml non-ionic contrast material were bolus injected through antecubital vein with. These dynamic images were processed with the 'Perfusion CT' software package on a PC based workstation. Cerebral blood flow (CBF) and time to peak (TP) enhancement were measured within specific regions of the brain on CT perfusion images. Quantitative analysis was performed for these images. Results: A gradient of perfusion between gray matter and white matter was showed on cT perfusion images in normal adults and TIA patients. CBF and TP for normal cortical and white matter were 378.2 ml·min -1 ·L -1 , 7.8 s and 112.5 ml·min -1 ·L -1 , 9.9 s, respectively. In 20 cases with TIA, persisting abnormal perfusion changes corresponding to clinical symptoms were found in 15 cases with prolonged TP. Other 5 cases showed normal results. TP of affected side (11.8 +- 4.4) s compared with that of the contralateral side (9.1 +- 3.1) s was significantly prolonged (t = 5.277, P -1 · -1 ] and contralateral side [(229.1 +- 41.4) ml·min -1 ·L -1 ]. Conclusion: Perfusion CT provides valuable hemodynamic information and shows the extent of perfusion disturbances for patients with TIA

  8. Serial lung imaging with /sup 123/I-IMP in localized pulmonary lesions

    Energy Technology Data Exchange (ETDEWEB)

    Nakajo, Masayuki; Shimada, Jurio; Shimozono, Michiko; Uchiyama, Noriaki; Hiraki, Yoshiyuki; Shinohara, Shinji.

    1988-05-01

    /sup 123/I-IMP (N-isopropyl-p-(/sup 123/I)-iodoamphetamine) dynamic (1 frame/min for 25 mins), 30-min and 4-hr static lung imaging was performed in a total of 65 patients with roentgenographic evidence of localized pulmonary lesion (12 with pneumonia, one with lung abscess, 5 with pulmonary tuberculosis, 3 with pneumoconiosis, one with lung fluke disease and 43 with various histological types of primary lung cancer). The findings in 65 of 70 (95 %) lesions in the initial 1 or 2-min dynamic /sup 123/I-IMP images were analogous to those obtained by /sup 99m/Tc-MAA lung perfusion imaging and decreased activity was observed in 68 of 70 (97 %) lesions, suggesting that the initial images mainly reflected the relative distribution of pulmonary arterial blood flow. However, /sup 123/I-IMP accumulated differently according to the pathological conditions afterwards. Decrease activity from /sup 123/I-IMP was contineously observed in a cavity of the lung abscess, 2 of 2 tuberculomas, 3 of 7 large nodules of pneumoconiosis and all of the 42 cancerous lesions which were possible to be evaluated. Gradual increased in activity relative to that of ''normal lung fields'' was observed in all 14 lesions of pneumonia; pneumonic lesions of the lung abscess, tuberculosis and lung fluke disease; 4 of 7 large nodules of pneumoconiosis; all of 8 atelectatic lesions and 32 of 44 areas surrounding cancers (most of them had roentgenographic evidence of infiltrating shadows). Thus /sup 123/I-IMP accumulated increasingly in pneumonic and atelectatic lesions, while it appeared not to accumulate in such lesions replacing lung tissues as cavity, caseous and fibrous lesions and primary lung cancers. /sup 123/I-IMP can be used as a new lung imaging agent to provide diagnostic informations on the property of pulmonary lesions.

  9. Clinical study of regional ventilation and perfusion of pulmonary disease by ventilatory steady state measurement with Xe-133

    Energy Technology Data Exchange (ETDEWEB)

    Nishi, Fumiaki

    1984-12-01

    Ventilatory steady state measurement with Xe-133 were performed to evaluate regional ventilation (V radical) and perfusion (Q radical) in 60 cases of primary lung cancer and 39 cases of pulmonary diseases-chronic obstructive pulmonary disease (COPD), pulmonary fibrosis, sarcoidosis, mitral stenosis with pulmonary hypertension (PH), pulmonary alveolar proteinosis, bronchial adenoma and pulmonary embolism. Of 60 cases of lung cancer, 11 cases showed V radicalQ radical mismatch (18%). Even in the V radicalQ radical matched defect cases, a different grade of disorder was seen in V radical and Q radical and the grade of Q radical was severer than the grade of V radical. Of 38 cases irradiated by Linac X-ray, 3 cases whose V radical, Q radical were disordered a little before irradiation recovered completely to normal range after irradiadiation. Of 38 cases subjected to radiation therapy, radiation injury of lung was recognized in 22 cases. In the cases of recovered V radical, Q radical after irradiation, radiation injury of lung occurred, and then V radical, Q radical disordered and returned to pre-irradiation value. In the cases that recovered little in V radical, Q radical, radiation injury of lung occurred, and then V radical, Q radical could not return to pre-irradiation value. In 39 cases of pulmonary diseases, 7 cases of sarcoidosis showed normal V radical and Q radical value. 13 cases of COPD was available to evaluate the regional pulmonary function in MTT (Mean Transit Time). V radical, Q radical were slightly disordered and MTT proloned slightly in 10 cases of diffuse pulmonary fibrosis where a marked fibrosis lesion was remarkable. Six cases of PH showed significant correlation between the left ventricular mean pressure and the perfusion ratio of upper and lower lung field. (J.P.N.).

  10. Clinical study of regional ventilation and perfusion of pulmonary disease by ventilatory steady state measurement with Xe-133

    International Nuclear Information System (INIS)

    Nishi, Fumiaki

    1984-01-01

    Ventilatory steady state measurement with Xe-133 were performed to evaluate regional ventilation (V radical) and perfusion (Q radical) in 60 cases of primary lung cancer and 39 cases of pulmonary diseases-chronic obstructive pulmonary disease (COPD), pulmonary fibrosis, sarcoidosis, mitral stenosis with pulmonary hypertension (PH), pulmonary alveolar proteinosis, bronchial adenoma and pulmonary embolism. Of 60 cases of lung cancer, 11 cases showed V radicalQ radical mismatch (18%). Even in the V radicalQ radical matched defect cases, a different grade of disorder was seen in V radical and Q radical and the grade of Q radical was severer than the grade of V radical. Of 38 cases irradiated by Linac X-ray, 3 cases whose V radical, Q radical were disordered a little before irradiation recovered completely to normal range after irradiadiation. Of 38 cases who performed the radiation therapy, radiation injury of lung was recognized in 22 cases. In the cases of recovered V radical, Q radical after irradiation, radiation injury of lung occurred, and then V radical, Q radical disordered and returned to pre-irradiation value. In the cases that recovered little in V radical, Q radical, radiation injury of lung occurred, and then V radical, Q radical could not return to pre-irradiation value. In 39 cases of pulmonary diseases, 7 cases of sarcoidosis showed normal V radical and Q radical value. 13 cases of COPD was available to evaluate the regional pulmonary function in MTT (Mean Transit Time). V radical, Q radical were slightly disordered and MTT proloned slightly in 10 cases of diffuse pulmonary fibrosis where a marked fibrosis lesion was remarkable. Six cases of PH showed significant correlation between the left ventricular mean pressure and the perfusion ratio of upper and lower lung field. (J.P.N.)

  11. Dosimetry in myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Toledo, Janine M.; Trindade, Bruno; Ribeiro, Tarcisio P.C. [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte (Brazil). Dept. de Engenharia Nuclear. Programa de Pos-Graduacao em Ciencias e Tecnicas Nucleares

    2011-07-01

    This paper conducts a dosimetric investigation on the myocardial perfusion image protocol, together with a literature reviewing, motivated by the significant statistic increasing on mortality, morbidity and disability associated with cardiovascular disease, surpassing infectious diseases. Nuclear Cardiology plays a role n the diagnostic functional evaluation of the heart and in the prognostic of patients with suspected or known cardiac ischemia. In the context of unstable myocardial ischemic syndrome, myocardial perfusion scintigraphy is a non-invasive procedure performed by administering a radiopharmaceutical targeted to the heart. As tool for this study are that the images obtained by thoracic angiotomography and abdominal aorta as a anatomic and functional information for model reproduction in SISCODES - System of Codes for Absorbed Dose Calculations based on Stochastic Methods. Data were manipulated in order to create a voxel computational model of the heart to be running in MCNP - Monte Carlo Neutron Particle Code. . It was assumed a homogeneous distribution of Tl-201 in cardiac muscle. Simulations of the transport of particles through the voxel and the interaction with the heart tissue were performed. As a result, the isodose curves in the heart model are displayed as well as the dose versus volume histogram of the heart muscle. We conclude that the present computational tools can generate doses distributed in myocardial perfusion. (author)

  12. Dosimetry in myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Toledo, Janine M.; Trindade, Bruno; Ribeiro, Tarcisio P.C.

    2011-01-01

    This paper conducts a dosimetric investigation on the myocardial perfusion image protocol, together with a literature reviewing, motivated by the significant statistic increasing on mortality, morbidity and disability associated with cardiovascular disease, surpassing infectious diseases. Nuclear Cardiology plays a role n the diagnostic functional evaluation of the heart and in the prognostic of patients with suspected or known cardiac ischemia. In the context of unstable myocardial ischemic syndrome, myocardial perfusion scintigraphy is a non-invasive procedure performed by administering a radiopharmaceutical targeted to the heart. As tool for this study are that the images obtained by thoracic angiotomography and abdominal aorta as a anatomic and functional information for model reproduction in SISCODES - System of Codes for Absorbed Dose Calculations based on Stochastic Methods. Data were manipulated in order to create a voxel computational model of the heart to be running in MCNP - Monte Carlo Neutron Particle Code. . It was assumed a homogeneous distribution of Tl-201 in cardiac muscle. Simulations of the transport of particles through the voxel and the interaction with the heart tissue were performed. As a result, the isodose curves in the heart model are displayed as well as the dose versus volume histogram of the heart muscle. We conclude that the present computational tools can generate doses distributed in myocardial perfusion. (author)

  13. SPECT/CT and pulmonary embolism

    DEFF Research Database (Denmark)

    Mortensen, Jann; Borgwardt, Henrik Gutte

    2014-01-01

    the best diagnostic accuracy for PE. In addition, recent developments in the CTPA technique have made it possible to image the pulmonary arteries of the lungs in one breath-hold. This development is based on the change from a single-detector to multidetector CT technology with an increase in volume......Acute pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/P) scintigraphy or pulmonary CT angiography (CTPA). In recent years both techniques have improved. Many nuclear medicine centres have adopted the single photon emission CT (SPECT) technique as opposed to the planar...

  14. Kombineret ventilations/perfusions-SPECT/CT er bedst til diagnostik af lungeemboli

    DEFF Research Database (Denmark)

    Gutte Borgwardt, Henrik; Mortensen, Jann; Kristoffersen, Ulrik Sloth

    2012-01-01

    The diagnosis of pulmonary embolism (PE) is usually established by a combination of clinical assessment, D-dimer test and imaging with either lung scintigraphy or pulmonary multidetector computed tomography angiography (CTA). Which of the two methods to use in PE diagnostic has not been determined...... and very limited data comparing these modalities are available. With the use of hybrid scanners, ventilation/perfusion-single-photon-emission-tomography (V/Q-SPECT) in combination with low-dose CT without contrast enhancement is feasible and should probably be considered first-line imaging in diagnosing PE....

  15. The role of perfusion lung scanning and diffusion capacity for early diagnosis of micro circulatory disturbances in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Petrova, D.; Shoshlov, P.; Hadjikostova, H.

    2002-01-01

    The development of chronic obstructive pulmonary disease (COPD) and the frequent inflammatory exacerbations with development of respiratory failure lead to changes in the micro circulatory and an increased risk of lung thrombotic and thromboembolic complication. The aim of the study was to establish the possibility of the perfusion lung scanning and diffusion capacity for early diagnosis of pulmonary micro circulatory disturbances in COPD with mild and moderate respiratory failure. 59 COPD patients were investigated. The data presented significant segmental disorders. Only in 5 (8.47%) of them the perfusion lung scintigrams were normal. In 23 of the patients, single-breath diffusing capacity (DICO) and its two components: membranous component (Dm) and capillary blood component (Vc) were determined. DICO was lower especially Vc the mean sign of micro circulatory disorders. A relationship between the degree of hypoxaemia and the changes found in the perfusion scintigraphy was found. Changes in the pulmonary lung scanning and in the diffusion capacity in COPD with mild respiratory failure seem to be an early diagnostic test. The early anticoagulant and desaggregant prevention may decrease the risk of thrombotic complications in the development of the disease. (authors)

  16. Radioaerosol Inhalation Lung Scan in Pulmonary Emphysema

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Jeong Soo; Park, Yong Ha; Kyo, Chung Soo; Bahk, Yong Whee [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1990-07-15

    Perfusion and ventilation imagings of the lung are well established procedure for diagnosing pulmonary embolism, differentiation it from chronic obstructive lung disease, and making an early detection of chronic obstructive lung disease. To evaluate the usefulness of radioaerosol inhalation imaging (RII) in chronic obstructive lung disease, especially pulmonary emphysema, we analyzed RIIs of five normal adult non-smokers, five asymptomatic smokers (age 25-42 years with the mean 36), and 21 patients with pulmonary emphysema (age 59-78 years with the mean 67). Scintigrams were obtained with radioaerosol produced by a BARC nebuliser with 15 mCi of {sup 99m}Tc-phytate. Scanning was performed in the anterior, posterior, and lateral projections after five to 10-minute inhalation of the radioaerosol on sitting position. The scans were analyzed and correlated with the results of pulmonary function studies and chest radiographs. Also lung perfusion scan with {sup 99m}Tc-MAA was performed in 12 patients. In five patients, we performed follow-up scans for the evaluation of the effects of a bronchodilator. Based on the X-ray findings and clinical symptoms, pulmonary emphysema was classified into four types: centrilobular (3 patients), panlobular (4 patients), intermediate (10 patients), and combined (4 patients). RII findings were patternized according to the type, extent, and intensity of the aerosol deposition in the central bronchial and bronchopulmonary system and lung parenchyma. 10 controls, normal five non-smokers and three asymptomatic smokers revealed homogeneous parenchymal deposition in the entire lung fields without central bronchial deposition. The remaining two of asymptomatic smokers revealed mild central airway deposition. The great majority of the patients showed either central (9/21) or combined type (10/21) of bronchopulmonary deposition and the remaining two patients peripheral bronchopulmonary deposition. Parenchymal aerosol deposition in pulmonary

  17. Radioaerosol Inhalation Lung Scan in Pulmonary Emphysema

    International Nuclear Information System (INIS)

    Jeon, Jeong Soo; Park, Yong Ha; Chung Soo Kyo; Bahk, Yong Whee

    1990-01-01

    Perfusion and ventilation imagings of the lung are well established procedure for diagnosing pulmonary embolism, differentiation it from chronic obstructive lung disease, and making an early detection of chronic obstructive lung disease. To evaluate the usefulness of radioaerosol inhalation imaging (RII) in chronic obstructive lung disease, especially pulmonary emphysema, we analyzed RIIs of five normal adult non-smokers, five asymptomatic smokers (age 25-42 years with the mean 36), and 21 patients with pulmonary emphysema (age 59-78 years with the mean 67). Scintigrams were obtained with radioaerosol produced by a BARC nebuliser with 15 mCi of 99m Tc-phytate. Scanning was performed in the anterior, posterior, and lateral projections after five to 10-minute inhalation of the radioaerosol on sitting position. The scans were analyzed and correlated with the results of pulmonary function studies and chest radiographs. Also lung perfusion scan with 99m Tc-MAA was performed in 12 patients. In five patients, we performed follow-up scans for the evaluation of the effects of a bronchodilator. Based on the X-ray findings and clinical symptoms, pulmonary emphysema was classified into four types: centrilobular (3 patients), panlobular (4 patients), intermediate (10 patients), and combined (4 patients). RII findings were patternized according to the type, extent, and intensity of the aerosol deposition in the central bronchial and bronchopulmonary system and lung parenchyma. 10 controls, normal five non-smokers and three asymptomatic smokers revealed homogeneous parenchymal deposition in the entire lung fields without central bronchial deposition. The remaining two of asymptomatic smokers revealed mild central airway deposition. The great majority of the patients showed either central (9/21) or combined type (10/21) of bronchopulmonary deposition and the remaining two patients peripheral bronchopulmonary deposition. Parenchymal aerosol deposition in pulmonary emphysema was

  18. Evaluation of renal transplant perfusion by functional imaging

    International Nuclear Information System (INIS)

    Nicoletti, R.

    1990-01-01

    Radionuclide angiography (RNA) is used as a noninvasive method for the evaluation of renal transplant perfusion. The computer processing method generally used, based on regions of interest, is unsatisfactory because it does not permit the regional differentiation of perfusion defects. Furthermore, the subjective delineation of the regions of interest introduces considerable inter-observer variation of results. We developed a processing method which is less operator-dependent and permits the evaluation of local defects; it is based on the concept of functional imaging. The method was evaluated in 62 patient examinations, which were subdivided into four groups: Normal transplant perfusion (23 examinations), acute tubular necrose (ATN) (16), cellular rejection (13), and vascular rejection (10). Quantitative results derived from profile curves were combined with visual estimation of the functional images and yielded a synoptic graph which allowed differentiation into three groups: Normal transplant perfusion (sensitivity 0.78, specificity 0.97), ATN or cellular rejection (sens. 0.83, spec. 0.82), and vascular rejection (sens. 0.90, spec. 0.92). (orig.)

  19. Isolated lung perfusion with gemcitabine for the treatment of pulmonary metastases : Experimental study in a rat model

    NARCIS (Netherlands)

    Putte, B.P. van

    2003-01-01

    Isolated lung perfusion is an experimental surgical technique for the treatment of pulmonary metastases in order to improve the current 5-year survival of approximately 40 % after surgical resection of manually palpable metastases. Several drugs have been tested in animals models and five phase I

  20. Parametric imaging of tumor perfusion and neovascular morphology using ultrasound

    Science.gov (United States)

    Hoyt, Kenneth

    2015-03-01

    A new image processing strategy is detailed for the simultaneous measurement of tumor perfusion and neovascular morphology parameters from a sequence of dynamic contrast-enhanced ultrasound (DCE-US) images. A technique for locally mapping tumor perfusion parameters using skeletonized neovascular data is also introduced. Simulated images were used to test the neovascular skeletonization technique and variance (error) of relevant parametric estimates. Preliminary DCE-US image datasets were collected in 6 female patients diagnosed with invasive breast cancer and using a Philips iU22 ultrasound system equipped with a L9-3 MHz transducer and Definity contrast agent. Simulation data demonstrates that neovascular morphology parametric estimation is reproducible albeit measurement error can occur at a lower signal-to-noise ratio (SNR). Experimental results indicate the feasibility of our approach to performing both tumor perfusion and neovascular morphology measurements from DCE-US images. Future work will expand on our initial clinical findings and also extent our image processing strategy to 3-dimensional space to allow whole tumor characterization.

  1. Magnetic resonance imaging compared with echocardiography in the evaluation of pulmonary artery abnormalities in children with tetralogy of Fallot following palliative and corrective surgery

    International Nuclear Information System (INIS)

    Greenberg, S.B.; Crisci, K.L.; Koenig, P.; Robinson, B.; Anisman, P.; Russo, P.

    1997-01-01

    Background. Abnormalities of the pulmonary arteries following palliative or corrective surgery for tetralogy of Fallot (TOF) are common. Our purpose was to compare the usefulness of magnetic resonance imaging (MRI) and echocardiography in the post- operative evaluation of the pulmonary arteries in children with TOF. Objective. Our hypothesis was that MRI is more sensitive than echocardiography in the detection of branch pulmonary artery abnormalities in children with TOF. Materials and methods. Pulmonary artery MRI and echocardiography were performed in 20 children following palliative and/or corrective surgery for TOF. MRI and echocardiography were compared in their ability to detect abnormalities of the pulmonary arteries. Angiographic or surgical correlation was available in 15 children. A perfusion scan for confirmation of pulmonary artery patency was available in one additional child. Results. Abnormalities of the branch pulmonary arteries identified by MRI included: absence or occlusion (2), focal stenosis (15), hypoplasia (2), aneurysm (1), and non-confluence (1). Echocardiography could not adequately visualize the right and left branch pulmonary arteries in eight and ten children, respectively. Echocardiography missed stenosis in 13 branch pulmonary arteries, patency of hypoplastic pulmonary arteries in two children, non-confluence of the pulmonary arteries in one child, and a left pulmonary artery aneurysm in one child. Abnormalities identified by MRI were confirmed in 16 children by angiography, surgery or perfusion scan. Conclusion. MRI is more sensitive than echocardiography for the evaluation of branch pulmonary artery abnormalities in children following surgery for TOF. (orig.)

  2. Pediatric hemiplegic migraine: susceptibility weighted and MR perfusion imaging abnormality

    Energy Technology Data Exchange (ETDEWEB)

    Altinok, Deniz; Agarwal, Ajay [Children' s Hospital of Michigan, Department of Radiology, Detroit, MI (United States); Ascadi, Gyula; Luat, Aimee; Tapos, Daniela [Children' s Hospital of Michigan, Department of Neurology, Detroit, MI (United States)

    2010-12-15

    We report on an 11-year-old girl suffering from a typical attack of hemiplegic migraine with characteristic abnormalities in perfusion MR and susceptibility-weighted MR imaging findings. The imaging abnormalities were resolved 48 h after the attack. Susceptibility-weighted MR imaging findings correlated well with the MR perfusion, thus it can be used along with conventional MRI for evaluation of children with complex migraine attacks. Susceptibility-weighted MR imaging might have a diagnostic role in assessing the vascular events in hemiplegic migraine. (orig.)

  3. Pediatric hemiplegic migraine: susceptibility weighted and MR perfusion imaging abnormality

    International Nuclear Information System (INIS)

    Altinok, Deniz; Agarwal, Ajay; Ascadi, Gyula; Luat, Aimee; Tapos, Daniela

    2010-01-01

    We report on an 11-year-old girl suffering from a typical attack of hemiplegic migraine with characteristic abnormalities in perfusion MR and susceptibility-weighted MR imaging findings. The imaging abnormalities were resolved 48 h after the attack. Susceptibility-weighted MR imaging findings correlated well with the MR perfusion, thus it can be used along with conventional MRI for evaluation of children with complex migraine attacks. Susceptibility-weighted MR imaging might have a diagnostic role in assessing the vascular events in hemiplegic migraine. (orig.)

  4. Respiratory lung motion analysis using a nonlinear motion correction technique for respiratory-gated lung perfusion SPECT images

    International Nuclear Information System (INIS)

    Ue, Hidenori; Haneishi, Hideaki; Iwanaga, Hideyuki; Suga, Kazuyoshi

    2007-01-01

    This study evaluated the respiratory motion of lungs using a nonlinear motion correction technique for respiratory-gated single photon emission computed tomography (SPECT) images. The motion correction technique corrects the respiratory motion of the lungs nonlinearly between two-phase images obtained by respiratory-gated SPECT. The displacement vectors resulting from respiration can be computed at every location of the lungs. Respiratory lung motion analysis is carried out by calculating the mean value of the body axis component of the displacement vector in each of the 12 small regions into which the lungs were divided. In order to enable inter-patient comparison, the 12 mean values were normalized by the length of the lung region along the direction of the body axis. This method was applied to 25 Technetium (Tc)-99m-macroaggregated albumin (MAA) perfusion SPECT images, and motion analysis results were compared with the diagnostic results. It was confirmed that the respiratory lung motion reflects the ventilation function. A statistically significant difference in the amount of the respiratory lung motion was observed between the obstructive pulmonary diseases and other conditions, based on an unpaired Student's t test (P<0.0001). A difference in the motion between normal lungs and lungs with a ventilation obstruction was detected by the proposed method. This method is effective for evaluating obstructive pulmonary diseases such as pulmonary emphysema and diffuse panbronchiolitis. (author)

  5. Quantitative perfusion imaging in magnetic resonance imaging; Quantitative Perfusionsbildgebung in der Magnetresonanztomographie

    Energy Technology Data Exchange (ETDEWEB)

    Zoellner, F.G.; Gaa, T.; Zimmer, F. [Universitaet Heidelberg, Computerunterstuetzte Klinische Medizin, Medizinische Fakultaet Mannheim, Mannheim (Germany); Ong, M.M.; Riffel, P.; Hausmann, D.; Schoenberg, S.O.; Weis, M. [Universitaet Heidelberg, Institut fuer Klinische Radiologie und Nuklearmedizin, Universitaetsmedizin Mannheim, Medizinische Fakultaet Mannheim, Mannheim (Germany)

    2016-02-15

    Magnetic resonance imaging (MRI) is recognized for its superior tissue contrast while being non-invasive and free of ionizing radiation. Due to the development of new scanner hardware and fast imaging techniques during the last decades, access to tissue and organ functions became possible. One of these functional imaging techniques is perfusion imaging with which tissue perfusion and capillary permeability can be determined from dynamic imaging data. Perfusion imaging by MRI can be performed by two approaches, arterial spin labeling (ASL) and dynamic contrast-enhanced (DCE) MRI. While the first method uses magnetically labelled water protons in arterial blood as an endogenous tracer, the latter involves the injection of a contrast agent, usually gadolinium (Gd), as a tracer for calculating hemodynamic parameters. Studies have demonstrated the potential of perfusion MRI for diagnostics and also for therapy monitoring. The utilization and application of perfusion MRI are still restricted to specialized centers, such as university hospitals. A broad application of the technique has not yet been implemented. The MRI perfusion technique is a valuable tool that might come broadly available after implementation of standards on European and international levels. Such efforts are being promoted by the respective professional bodies. (orig.) [German] Die Magnetresonanztomographie (MRT) zeichnet sich durch einen ueberlegenen Gewebekontrast aus, waehrend sie nichtinvasiv und frei von ionisierender Strahlung ist. Sie bietet Zugang zu Gewebe- und Organfunktion. Eine dieser funktionellen bildgebenden Verfahren ist die Perfusionsbildgebung. Mit dieser Technik koennen u. a. Gewebeperfusion und Kapillarpermeabilitaet aus dynamischen Bilddaten bestimmt werden. Perfusionsbildgebung mithilfe der MRT kann durch 2 Ansaetze, naemlich ''arterial spin labeling'' (ASL) und dynamische kontrastverstaerkte (DCE-)MRT durchgefuehrt werden. Waehrend die erste Methode magnetisch

  6. Safety of adenosine in stress cerebral perfusion imaging

    International Nuclear Information System (INIS)

    Hu Pengcheng; Gu Yushen; Liu Wenguan; Xiu Yan; Zhu Weimin; Chen Shuguang; Shi Hongcheng

    2009-01-01

    Objective: To evaluate the safety of adenosine as pharmacological stress agents in stress cerebral perfusion imaging. Methods: Eighty patients under investigation for suspected cerebral vessel disease were recruited. Each had a resting scan and a stress scan on different days. The adenosine stress protocol was as same as the protocol used in adenosine stress myocardial perfusion imaging. Subjective and objective side-effects were investigated during pharmacological stress procedure. Results: All patients completed the 6 min infusion protocol without premature termination on safety criteria or due to intolerable symptoms. 46 patients had mild side effects. 20 patients (25%) had dizziness, 12 patients (15%) had palpitation, 1 patient (1%) was hypotensive, 7 patients (9%) had dyspnoea, 4 patients (5%) felt hot, 3 patients (4%) had sweat, 4 patients (5%) had nausea, 6 patients (8%) had flushing, 19 patients (24%) had chest pain, 6 patients (8%) had abdomen pain, 3 patients (4%) had abnormal taste and 1 patient (1%) were thirsty. Transient ST change occurred in only 1 patient. Conclusion: Adenosine stress cerebral perfusion imaging is a safe diagnostic method with mild side effects. (authors)

  7. Management of Liver Cancer Argon-helium Knife Therapy with Functional Computer Tomography Perfusion Imaging.

    Science.gov (United States)

    Wang, Hongbo; Shu, Shengjie; Li, Jinping; Jiang, Huijie

    2016-02-01

    The objective of this study was to observe the change in blood perfusion of liver cancer following argon-helium knife treatment with functional computer tomography perfusion imaging. Twenty-seven patients with primary liver cancer treated with argon-helium knife and were included in this study. Plain computer tomography (CT) and computer tomography perfusion (CTP) imaging were conducted in all patients before and after treatment. Perfusion parameters including blood flows, blood volume, hepatic artery perfusion fraction, hepatic artery perfusion, and hepatic portal venous perfusion were used for evaluating therapeutic effect. All parameters in liver cancer were significantly decreased after argon-helium knife treatment (p knife therapy. Therefore, CTP imaging would play an important role for liver cancer management followed argon-helium knife therapy. © The Author(s) 2014.

  8. Accuracy and Utility of Deformable Image Registration in 68Ga 4D PET/CT Assessment of Pulmonary Perfusion Changes During and After Lung Radiation Therapy

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Hofman, Michael S.; Hicks, Rodney J.; Callahan, Jason; Kron, Tomas; MacManus, Michael P.; Ball, David L.; Jackson, Price; Siva, Shankar

    2015-01-01

    Purpose: Measuring changes in lung perfusion resulting from radiation therapy dose requires registration of the functional imaging to the radiation therapy treatment planning scan. This study investigates registration accuracy and utility for positron emission tomography (PET)/computed tomography (CT) perfusion imaging in radiation therapy for non–small cell lung cancer. Methods: 68 Ga 4-dimensional PET/CT ventilation-perfusion imaging was performed before, during, and after radiation therapy for 5 patients. Rigid registration and deformable image registration (DIR) using B-splines and Demons algorithms was performed with the CT data to obtain a deformation map between the functional images and planning CT. Contour propagation accuracy and correspondence of anatomic features were used to assess registration accuracy. Wilcoxon signed-rank test was used to determine statistical significance. Changes in lung perfusion resulting from radiation therapy dose were calculated for each registration method for each patient and averaged over all patients. Results: With B-splines/Demons DIR, median distance to agreement between lung contours reduced modestly by 0.9/1.1 mm, 1.3/1.6 mm, and 1.3/1.6 mm for pretreatment, midtreatment, and posttreatment (P<.01 for all), and median Dice score between lung contours improved by 0.04/0.04, 0.05/0.05, and 0.05/0.05 for pretreatment, midtreatment, and posttreatment (P<.001 for all). Distance between anatomic features reduced with DIR by median 2.5 mm and 2.8 for pretreatment and midtreatment time points, respectively (P=.001) and 1.4 mm for posttreatment (P>.2). Poorer posttreatment results were likely caused by posttreatment pneumonitis and tumor regression. Up to 80% standardized uptake value loss in perfusion scans was observed. There was limited change in the loss in lung perfusion between registration methods; however, Demons resulted in larger interpatient variation compared with rigid and B-splines registration. Conclusions

  9. Thallium-201 myocardial perfusion imaging during transient coronary occlusion at the time of PTCA

    International Nuclear Information System (INIS)

    Nakagawa, Tatsuya; Sugihara, Hiroki; Inagaki, Suetsugu

    1989-01-01

    To evaluate myocardial perfusion during transient coronary arterial occlusion, thallium-201 was administered intravenously during percutaneous transluminall coronary angioplasty (PTCA) in 12 patients with effort angina, and the resulting perfusion images were compared with those of exercise stress obtained before PTCA. Thallium-201 was injected at the last inflation of an angioplastic baloon and occlusion was maintained for 60 to 90 sec. Three projections of planar images were obtained immediately after PTCA, using a portable gamma camera in an angiography room. These perfusion images obtained during PTCA and exercise were visually interpreted and compared. Myocardial perfusion defects due to the responsible vessel occlusion were observed at early imaging after PTCA, and were fully redistributed three hrs post injection. In 10 patients without angiographically imaged collateral vessels, there were no significatn differences in perfusion between images during PTCA and during exercise. Two patients whose collaterals were observed during coronary angiography before PTCA had higher perfusion scores during PTCA than during exercise. We concluded that intravenous injection of thallium-201 during PTCA is a useful means for assessing alteration of myocardial perfusion due to transient coronary occlusion without increasing the risk of angioplastic procedures, and that it provides more precise information about the jeopardized myocardium, perfused by antegrade blood flow. (author)

  10. Scintigraphic evidence for overdiagnosis of small PE on CT pulmonary angiography

    International Nuclear Information System (INIS)

    Lu, Yang

    2017-01-01

    A 68-year-old man with recent history of a fall presented with dyspnea on exertion, and underwent computed tomography pulmonary angiography (CTPA) for possible pulmonary embolism (PE). The CTPA was first read by the radiology resident as nondiagnostic for segmental PE. Subsequent planar perfusion (Q) images were normal; meanwhile, the attending radiologist revised the CTPA results as subsegmental PE in the left upper lobe. Further Q-SPECT images were obtained and fused with CTPA for clarification, which showed normal perfusion in the region of PE. The patient was monitored without anticoagulation treatment and remained uneventful for 12 months. This case illustrates that CTPA can lead to overdiagnosis and overtreatment of nonocclusive subsegmental PE

  11. Patient satisfaction with coronary CT angiography, myocardial CT perfusion, myocardial perfusion MRI, SPECT myocardial perfusion imaging and conventional coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Feger, S.; Rief, M.; Zimmermann, E.; Richter, F.; Roehle, R. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Dewey, M. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Institut fuer Radiologie, Berlin (Germany); Schoenenberger, E. [Medizinische Hochschule Hannover, Department of Medicine, Hannover (Germany)

    2015-07-15

    To evaluate patient acceptance of noninvasive imaging tests for detection of coronary artery disease (CAD), including single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI), stress perfusion magnetic resonance imaging (MRI), coronary CT angiography (CTA) in combination with CT myocardial stress perfusion (CTP), and conventional coronary angiography (CCA). Intraindividual comparison of perception of 48 patients from the CORE320 multicentre multinational study who underwent rest and stress SPECT-MPI with a technetium-based tracer, combined CTA and CTP (both with contrast agent, CTP with adenosine), MRI, and CCA. The analysis was performed by using a validated questionnaire. Patients had significantly more concern prior to CCA than before CTA/CTP (p < 0.001). CTA/CTP was also rated as more comfortable than SPECT-MPI (p = 0.001). Overall satisfaction with CT was superior to that of MRI (p = 0.007). More patients preferred CT (46 %; p < 0.001) as a future diagnostic test. Regarding combined CTA/CTP, CTP was characterised by higher pain levels and an increased frequency of angina pectoris during the examination (p < 0.001). Subgroup analysis showed a higher degree of pain during SPECT-MPI with adenosine stress compared to physical exercise (p = 0.016). All noninvasive cardiac imaging tests are well accepted by patients, with CT being the preferred examination. (orig.)

  12. Safety of ventilation/perfusion single photon emission computed tomography for pulmonary embolism diagnosis

    International Nuclear Information System (INIS)

    Le Roux, Pierre-Yves; Palard, Xavier; Robin, Philippe; Abgral, Ronan; Querellou, Solene; Salaun, Pierre-Yves; Delluc, Aurelien; Couturaud, Francis; Le Gal, Gregoire

    2014-01-01

    The aim of this management outcome study was to assess the safety of ventilation/perfusion single photon emission computed tomography (V/Q SPECT) for the diagnosis of pulmonary embolism (PE) using for interpretation the criteria proposed in the European Association of Nuclear Medicine (EANM) guidelines for V/Q scintigraphy. A total of 393 patients with clinically suspected PE referred to the Nuclear Medicine Department of Brest University Hospital from April 2011 to March 2013, with either a high clinical probability or a low or intermediate clinical probability but positive D-dimer, were retrospectively analysed. V/Q SPECT were interpreted by the attending nuclear medicine physician using a diagnostic cut-off of one segmental or two subsegmental mismatches. The final diagnostic conclusion was established by the physician responsible for patient care, based on clinical symptoms, laboratory test, V/Q SPECT and other imaging procedures performed. Patients in whom PE was deemed absent were not treated with anticoagulants and were followed up for 3 months. Of the 393 patients, the prevalence of PE was 28 %. V/Q SPECT was positive for PE in 110 patients (28 %) and negative in 283 patients (72 %). Of the 110 patients with a positive V/Q SPECT, 78 (71 %) had at least one additional imaging test (computed tomography pulmonary angiography or ultrasound) and the diagnosis of PE was eventually excluded in one patient. Of the 283 patients with a negative V/Q SPECT, 74 (26 %) patients had another test. The diagnosis of PE was finally retained in one patient and excluded in 282 patients. The 3-month thromboembolic risk in the patients not treated with anticoagulants was 1/262: 0.38 % (95 % confidence interval 0.07-2.13). A diagnostic management including V/Q SPECT interpreted with a diagnostic cut-off of ''one segmental or two subsegmental mismatches'' appears safe to exclude PE. (orig.)

  13. Safety of ventilation/perfusion single photon emission computed tomography for pulmonary embolism diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Le Roux, Pierre-Yves; Palard, Xavier; Robin, Philippe; Abgral, Ronan; Querellou, Solene; Salaun, Pierre-Yves [Universite Europeenne de Bretagne, Brest (France); Universite de Brest, Brest (France); CHRU de la Cavale Blanche, Service de medecine nucleaire, Brest (France); Delluc, Aurelien; Couturaud, Francis [Universite Europeenne de Bretagne, Brest (France); Universite de Brest, Brest (France); CHRU de la Cavale Blanche, Departement de medecine interne et de pneumologie, Brest (France); Le Gal, Gregoire [Universite Europeenne de Bretagne, Brest (France); University of Ottawa, Ottawa Hospital Research Institute, Ottawa (Canada); CHRU de la Cavale Blanche, Departement de medecine interne et de pneumologie, Brest (France); Universite de Brest, Brest (France)

    2014-10-15

    The aim of this management outcome study was to assess the safety of ventilation/perfusion single photon emission computed tomography (V/Q SPECT) for the diagnosis of pulmonary embolism (PE) using for interpretation the criteria proposed in the European Association of Nuclear Medicine (EANM) guidelines for V/Q scintigraphy. A total of 393 patients with clinically suspected PE referred to the Nuclear Medicine Department of Brest University Hospital from April 2011 to March 2013, with either a high clinical probability or a low or intermediate clinical probability but positive D-dimer, were retrospectively analysed. V/Q SPECT were interpreted by the attending nuclear medicine physician using a diagnostic cut-off of one segmental or two subsegmental mismatches. The final diagnostic conclusion was established by the physician responsible for patient care, based on clinical symptoms, laboratory test, V/Q SPECT and other imaging procedures performed. Patients in whom PE was deemed absent were not treated with anticoagulants and were followed up for 3 months. Of the 393 patients, the prevalence of PE was 28 %. V/Q SPECT was positive for PE in 110 patients (28 %) and negative in 283 patients (72 %). Of the 110 patients with a positive V/Q SPECT, 78 (71 %) had at least one additional imaging test (computed tomography pulmonary angiography or ultrasound) and the diagnosis of PE was eventually excluded in one patient. Of the 283 patients with a negative V/Q SPECT, 74 (26 %) patients had another test. The diagnosis of PE was finally retained in one patient and excluded in 282 patients. The 3-month thromboembolic risk in the patients not treated with anticoagulants was 1/262: 0.38 % (95 % confidence interval 0.07-2.13). A diagnostic management including V/Q SPECT interpreted with a diagnostic cut-off of ''one segmental or two subsegmental mismatches'' appears safe to exclude PE. (orig.)

  14. Phase correction of MR perfusion/diffusion images

    International Nuclear Information System (INIS)

    Chenevert, T.L.; Pipe, J.G.; Brunberg, J.A.; Yeung, H.N.

    1989-01-01

    Apparent diffusion coefficient (ADC) and perfusion MR sequences are exceptionally sensitive to minute motion and, therefore, are prone to bulk motions that hamper ADC/perfusion quantification. The authors have developed a phase correction algorithm to substantially reduce this error. The algorithm uses a diffusion-insensitive data set to correct data that are diffusion sensitive but phase corrupt. An assumption of the algorithm is that bulk motion phase shifts are uniform in one dimension, although they may be arbitrarily large and variable from acquisition to acquisition. This is facilitated by orthogonal section selection. The correction is applied after one Fourier transform of a two-dimensional Fourier transform reconstruction. Imaging experiments on rat and human brain demonstrate significant artifact reduction in ADC and perfusion measurements

  15. Serial perfusion in native lungs in patients with idiopathic pulmonary fibrosis and other interstitial lung diseases after single lung transplantation.

    Science.gov (United States)

    Sokai, Akihiko; Handa, Tomohiro; Chen, Fengshi; Tanizawa, Kiminobu; Aoyama, Akihiro; Kubo, Takeshi; Ikezoe, Kohei; Nakatsuka, Yoshinari; Oguma, Tsuyoshi; Hirai, Toyohiro; Nagai, Sonoko; Chin, Kazuo; Date, Hiroshi; Mishima, Michiaki

    2016-04-01

    Lung perfusions after single lung transplantation (SLT) have not been fully clarified in patients with interstitial lung disease (ILD). The present study aimed to investigate temporal changes in native lung perfusion and their associated clinical factors in patients with ILD who have undergone SLT. Eleven patients were enrolled. Perfusion scintigraphy was serially performed up to 12 months after SLT. Correlations between the post-operative perfusion ratio in the native lung and clinical parameters, including pre-operative perfusion ratio and computed tomography (CT) volumetric parameters, were evaluated. On average, the perfusion ratio of the native lung was maintained at approximately 30% until 12 months after SLT. However, the ratio declined more significantly in idiopathic pulmonary fibrosis (IPF) than in other ILDs (p = 0.014). The perfusion ratio before SLT was significantly correlated with that at three months after SLT (ρ = 0.64, p = 0.048). The temporal change of the perfusion ratio in the native lung did not correlate with those of the CT parameters. The pre-operative perfusion ratio may predict the post-operative perfusion ratio of the native lung shortly after SLT in ILD. Perfusion of the native lung may decline faster in IPF compared with other ILDs. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Prediction of residual lung function after lung surgery, and examination of blood perfusion in the pre- and postoperative lung using three-dimensional SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Shimatani, Shinji [Toho Univ., Tokyo (Japan). School of Medicine

    2001-01-01

    In order to predict postoperative pulmonary function after lung surgery, preoperative {sup 99m}Tc-macroaggregated albumin (MAA) lung perfusion scans with single-photon emission computed tomography (SPECT) were performed. Spirometry was also performed before and 4-6 months after surgery in 40 patients. In addition, changes in blood perfusion in the pre- and postoperative lung were examined by postoperative lung perfusion scans in 18 of the 40 patients. We measured the three-dimensional (3-D) imaging volume of the operative and contralateral lungs using the volumes rendering method at blood perfusion thresholds of 20, 50 and 75%, utilizing {sup 99m}Tc-MAA lung perfusion, and predicted pulmonary function by means of the measured volumes. We examined the correlation between predicted and the measured values of postoperative pulmonary function, forced vital capacity (FVC) and forced expiratory volume in one second (FEV{sub 1.0}). The correlation between FEV{sub 1.0} predicted by SPECT (threshold 50%) and measured postoperative lung function resembled that between lung function predicted by the standard planar method and measured FEV{sub 1.0} in the lobectomy group. We then examined the ratios of both pre- and postoperative blood perfusion volumes obtained using 3-D imaging at lung perfusion threshold ranges of 10% each (PV20-29, PV30-39) to pre- and postoperative total perfusion (PV20-100). In the lobectomy group, the postoperative PV20-29/PV20-100 value was significantly higher for the operative side lung than the preoperative PV20-29/PV20-100 value, and the postoperative PV50-59, 60-69, 70-79, 80-89 and 90-100/PV20-100 values were significantly lower than the respective preoperative values. However, in the contralateral lung, the respective pre- and postoperative PV/PV20-100 values were almost identical. These findings suggest that the rate of low blood perfusion increased while the rate of middle to high perfusion decreased in the lobectomy group in the operative

  17. Perfusion imaging with single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Holman, B.L.; Hill, T.C.

    1987-01-01

    SPECT with perfusion tracers is useful in a number of circumstances: (1) In acute cerebral infarction while the CT scan may be normal for several days after onset of symptoms, the uptake of SPECT perfusion tracers will be altered immediately after the onset of the stroke. Even when the CT scan has become abnormal, the physiologic abnormality may exceed the anatomic abnormality. One may, therefore be able to measure the extent of the reversibly ischemic tissue early enough to justify more agressive therapeutic interventions. (2) For endarterectomy and other surgical and medical therapies serial measurements of regional cerebral perfusion with SPECT may provide a readily available tool to assess their efficacy. (3) SPECT perfusion imaging may become the method of choice for the diagnosis and evaluation of Alzheimer's disease. (4) In patients with epilepsy, the extent and location of the abnormally perfused focus may be important to medical and surgical management. Follow-up examination may be useful in documenting the effectiveness of therapy

  18. Magnetic resonance imaging compared with echocardiography in the evaluation of pulmonary artery abnormalities in children with tetralogy of Fallot following palliative and corrective surgery

    Energy Technology Data Exchange (ETDEWEB)

    Greenberg, S.B.; Crisci, K.L.; Koenig, P.; Robinson, B.; Anisman, P.; Russo, P. [St. Christopher`s Hospital for Children, Front Street at Erie Avenue, Philadelphia, PA 19134 (United States)

    1997-12-01

    Background. Abnormalities of the pulmonary arteries following palliative or corrective surgery for tetralogy of Fallot (TOF) are common. Our purpose was to compare the usefulness of magnetic resonance imaging (MRI) and echocardiography in the post- operative evaluation of the pulmonary arteries in children with TOF. Objective. Our hypothesis was that MRI is more sensitive than echocardiography in the detection of branch pulmonary artery abnormalities in children with TOF. Materials and methods. Pulmonary artery MRI and echocardiography were performed in 20 children following palliative and/or corrective surgery for TOF. MRI and echocardiography were compared in their ability to detect abnormalities of the pulmonary arteries. Angiographic or surgical correlation was available in 15 children. A perfusion scan for confirmation of pulmonary artery patency was available in one additional child. Results. Abnormalities of the branch pulmonary arteries identified by MRI included: absence or occlusion (2), focal stenosis (15), hypoplasia (2), aneurysm (1), and non-confluence (1). Echocardiography could not adequately visualize the right and left branch pulmonary arteries in eight and ten children, respectively. Echocardiography missed stenosis in 13 branch pulmonary arteries, patency of hypoplastic pulmonary arteries in two children, non-confluence of the pulmonary arteries in one child, and a left pulmonary artery aneurysm in one child. Abnormalities identified by MRI were confirmed in 16 children by angiography, surgery or perfusion scan. Conclusion. MRI is more sensitive than echocardiography for the evaluation of branch pulmonary artery abnormalities in children following surgery for TOF. (orig.) With 2 figs., 3 tabs., 11 refs.

  19. Improved perfusion quantification in FAIR imaging by offset correction

    DEFF Research Database (Denmark)

    Sidaros, Karam; Andersen, Irene Klærke; Gesmar, Henrik

    2001-01-01

    Perfusion quantification using pulsed arterial spin labeling has been shown to be sensitive to the RF pulse slice profiles. Therefore, in Flow-sensitive Alternating-Inversion Recovery (FAIR) imaging the slice selective (ss) inversion slab is usually three to four times thicker than the imaging...... slice. However, this reduces perfusion sensitivity due to the increased transit delay of the incoming blood with unperturbed spins. In the present article, the dependence of the magnetization on the RF pulse slice profiles is inspected both theoretically and experimentally. A perfusion quantification...... model is presented that allows the use of thinner ss inversion slabs by taking into account the offset of RF slice profiles between ss and nonselective inversion slabs. This model was tested in both phantom and human studies. Magn Reson Med 46:193-197, 2001...

  20. Intra-voxel incoherent motion perfusion MR Imaging: a wake-up call

    Energy Technology Data Exchange (ETDEWEB)

    Le Bihan, D. [CEA Saclay, DSV, I2BM, F-91191 Gif Sur Yvette (France)

    2008-07-01

    This work gives the results of several studies made by different authors on IVIM MR Imaging. It appears that there are genuine potential applications for IVIM MR imaging. Perfusion is a very important surrogate marker of many physiologic or pathologic processes. MR imaging perfusion parameters can be obtained by using gadolinium-based contrast agents, either injected as a bolus (to determine blood flow, transit times, etc) or in a steady-state mode (to address blood volume, vessel permeability, etc). With the rising concern of nephrogenic systemic fibrosis, some patients cannot be examined with such an approach. IVIM MR imaging may then appear as an interesting alternative to provide crucial clues on perfusion in tissues, such as the kidneys, the liver, or even the placenta during pregnancy. (O.M.)

  1. Intra-voxel incoherent motion perfusion MR Imaging: a wake-up call

    International Nuclear Information System (INIS)

    Le Bihan, D.

    2008-01-01

    This work gives the results of several studies made by different authors on IVIM MR Imaging. It appears that there are genuine potential applications for IVIM MR imaging. Perfusion is a very important surrogate marker of many physiologic or pathologic processes. MR imaging perfusion parameters can be obtained by using gadolinium-based contrast agents, either injected as a bolus (to determine blood flow, transit times, etc) or in a steady-state mode (to address blood volume, vessel permeability, etc). With the rising concern of nephrogenic systemic fibrosis, some patients cannot be examined with such an approach. IVIM MR imaging may then appear as an interesting alternative to provide crucial clues on perfusion in tissues, such as the kidneys, the liver, or even the placenta during pregnancy. (O.M.)

  2. Accuracy and Utility of Deformable Image Registration in {sup 68}Ga 4D PET/CT Assessment of Pulmonary Perfusion Changes During and After Lung Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hardcastle, Nicholas, E-mail: nick.hardcastle@gmail.com [Department of Physical Sciences, Peter MacCallum Cancer Centre, East Melbourne (Australia); Centre for Medical Radiation Physics, University of Wollongong, Wollongong (Australia); Hofman, Michael S. [Molecular Imaging, Centre for Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne (Australia); Hicks, Rodney J. [Molecular Imaging, Centre for Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne (Australia); Department of Medicine, University of Melbourne, Melbourne (Australia); Callahan, Jason [Molecular Imaging, Centre for Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne (Australia); Kron, Tomas [Department of Medical Imaging and Radiation Sciences, Monash University, Clayton (Australia); The Sir Peter MacCallum Department of Oncology, Melbourne University, Victoria (Australia); MacManus, Michael P.; Ball, David L. [Division of Radiation Oncology and Cancer Imaging, Peter MacCallum Cancer Centre, East Melbourne (Australia); The Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne (Australia); Jackson, Price [Department of Physical Sciences, Peter MacCallum Cancer Centre, East Melbourne (Australia); Siva, Shankar [Division of Radiation Oncology and Cancer Imaging, Peter MacCallum Cancer Centre, East Melbourne (Australia)

    2015-09-01

    Purpose: Measuring changes in lung perfusion resulting from radiation therapy dose requires registration of the functional imaging to the radiation therapy treatment planning scan. This study investigates registration accuracy and utility for positron emission tomography (PET)/computed tomography (CT) perfusion imaging in radiation therapy for non–small cell lung cancer. Methods: {sup 68}Ga 4-dimensional PET/CT ventilation-perfusion imaging was performed before, during, and after radiation therapy for 5 patients. Rigid registration and deformable image registration (DIR) using B-splines and Demons algorithms was performed with the CT data to obtain a deformation map between the functional images and planning CT. Contour propagation accuracy and correspondence of anatomic features were used to assess registration accuracy. Wilcoxon signed-rank test was used to determine statistical significance. Changes in lung perfusion resulting from radiation therapy dose were calculated for each registration method for each patient and averaged over all patients. Results: With B-splines/Demons DIR, median distance to agreement between lung contours reduced modestly by 0.9/1.1 mm, 1.3/1.6 mm, and 1.3/1.6 mm for pretreatment, midtreatment, and posttreatment (P<.01 for all), and median Dice score between lung contours improved by 0.04/0.04, 0.05/0.05, and 0.05/0.05 for pretreatment, midtreatment, and posttreatment (P<.001 for all). Distance between anatomic features reduced with DIR by median 2.5 mm and 2.8 for pretreatment and midtreatment time points, respectively (P=.001) and 1.4 mm for posttreatment (P>.2). Poorer posttreatment results were likely caused by posttreatment pneumonitis and tumor regression. Up to 80% standardized uptake value loss in perfusion scans was observed. There was limited change in the loss in lung perfusion between registration methods; however, Demons resulted in larger interpatient variation compared with rigid and B-splines registration

  3. Volume perfusion CT imaging of cerebral vasospasm: diagnostic performance of different perfusion maps

    Energy Technology Data Exchange (ETDEWEB)

    Othman, Ahmed E. [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); Eberhard Karls University Tuebingen, University Hospital Tuebingen, Department for Diagnostic and Interventional Radiology, Tuebingen (Germany); Afat, Saif; Nikoubashman, Omid; Mueller, Marguerite; Wiesmann, Martin; Brockmann, Carolin [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); Schubert, Gerrit Alexander [RWTH Aachen University, Department of Neurosurgery, Aachen (Germany); Bier, Georg [Eberhard Karls University Tuebingen, University Hospital Tuebingen, Department for Diagnostic and Interventional Neuroradiology, Tuebingen (Germany); Brockmann, Marc A. [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); University Hospital Mainz, Department of Neuroradiology, Mainz (Germany)

    2016-08-15

    In this study, we aimed to evaluate the diagnostic performance of different volume perfusion CT (VPCT) maps regarding the detection of cerebral vasospasm compared to angiographic findings. Forty-one datasets of 26 patients (57.5 ± 10.8 years, 18 F) with subarachnoid hemorrhage and suspected cerebral vasospasm, who underwent VPCT and angiography within 6 h, were included. Two neuroradiologists independently evaluated the presence and severity of vasospasm on perfusion maps on a 3-point Likert scale (0 - no vasospasm, 1 - vasospasm affecting <50 %, 2 - vasospasm affecting >50 % of vascular territory). A third neuroradiologist independently assessed angiography for the presence and severity of vasospasm on a 3-point Likert scale (0 - no vasospasm, 1 - vasospasm affecting < 50 %, 2 - vasospasm affecting > 50 % of vessel diameter). Perfusion maps of cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and time to drain (TTD) were evaluated regarding diagnostic accuracy for cerebral vasospasm with angiography as reference standard. Correlation analysis of vasospasm severity on perfusion maps and angiographic images was performed. Furthermore, inter-reader agreement was assessed regarding findings on perfusion maps. Diagnostic accuracy for TTD and MTT was significantly higher than for all other perfusion maps (TTD, AUC = 0.832; MTT, AUC = 0.791; p < 0.001). TTD revealed higher sensitivity than MTT (p = 0.007). The severity of vasospasm on TTD maps showed significantly higher correlation levels with angiography than all other perfusion maps (p ≤ 0.048). Inter-reader agreement was (almost) perfect for all perfusion maps (kappa ≥ 0.927). The results of this study indicate that TTD maps have the highest sensitivity for the detection of cerebral vasospasm and highest correlation with angiography regarding the severity of vasospasm. (orig.)

  4. Ventilation-perfused studies using SPECT

    International Nuclear Information System (INIS)

    Zwijnenburg, A.

    1989-01-01

    A method for the quantitative analysis of ventilation-perfusion SPECT studies is decribed and an effort is made to evaluate its usefullness. The technical details of the emthod are described. In the the transaxial reconstructions of the tomographic studies the contour of the lungs is detected and regional values of lung volume, ventilation, perfusion and ventilation-perfusion ratios are calculated. The method is operator independent. The lung volume calculations from the SPECT studies are validated by comparing them with lung volume measurements using the helium dilution technique. A good correlation (r=0.91) was found between the two volumes. SPECT volume was greater than the volume measured with helium dilution, which was attributed to non-gas-containing structures in the. lungs. The use of ventilation-perfusion ratio SPECT is described to evaluate the effect of ionizing radiation on the lungs in patients treated with mantle field irradiation for Hodgkin's disease. Perfusion changes appear as early as 2 months after the start of irradiation. Ventilation changes appear later and relatively minor. No changes are seen outside the radiation portals. The ventilation-perfusion inequality in pulmonary sarcoidosis is treated. It is suggested that the decrease D LCO in these patients may be partly due to an even distribution of ventilation perfusion ratios. An effort is made to establish the properties of a new tracer used for the assessment of the metabolic function of the pulmonary endothelium. The lung uptake of I-123 IMP mimics the distribution of a perfusion tracer and it is suggested that this tracer may be useful for the early detection of pulmonary vascular damage, even when blood flow is still intact. Some aspects of the use of Kr-81m as a ventilation tracer are discussed as well as the effect of noise on Kr-81m SPECT reconstructions. (author). 146 refs.; 39 figs.; 8 tabs

  5. Pulmonary circulation

    International Nuclear Information System (INIS)

    Bongartz, G.; Boos, M.; Scheffler, K.; Steinbrich, W.

    1998-01-01

    Evaluation of the pulmonary vasculature is mainly indicated in patients with suspected pulmonary thromboembolism. The routine procedure so far is ventilation-perfusion scintigraphy alone or in combination with diagnostic assessment of the legs to rule out deep venous thrombosis. The results are still not reliable for the majority of patients. In the case of equivocal diagnosis, invasive conventional angiography is considered the gold standard. With steady improvements in tomographic imaging techniques, such as computed tomography (CT) or magnetic resonance imaging (MRI), non-invasive alternatives to the routine diagnostic work-up are given. Helical CT and CTA techniques are already in clinical use and estimated to sufficiently serve the demands for detection/exclusion of pulmonary thromboembolism. The disadvantages mainly concern peripheral disease and reconstruction artifacts. MRI and MR angiography have been implemented in the diagnosis of pulmonary vascular disease since the introduction of contrast-enhanced MRA. In breath-hold techniques, the entire lung vascularization can be delineated and thromboemboli can be detected. The clinical experience in this field is limited, but MRI has the potential to demonstrate its superiority over CT due to its improved delineation of the vascular periphery and the more comprehensive three-dimensional reconstruction. (orig.)

  6. SPECT brain perfusion imaging in mild traumatic brain injury

    International Nuclear Information System (INIS)

    Li Juan; Liu Baojun; Zhao Feng; He Lirong; Xia Yucheng

    2003-01-01

    Objective: To study the clinical value of SPECT brain perfusion imaging after mild traumatic brain injury and to evaluate the mechanism of brain blood flow changes in the brain traumatic symptoms. Methods: SPECT 99 Tc m -ethylene cysteinate dimer (ECD) brain perfusion imaging was performed on 39 patients with normal consciousness and normal computed tomography. The study was performed on 23 patients within 3 months after the accidental injury and on 16 patients at more than 3 months post-injury. The cerebellum was used as the reference site (100% maximum value). Any decrease in cerebral perfusion in cortex or basal ganglia to below 70%, or even to below 50% in the medial temporal lobe, compared to the cerebellar reference was considered abnormal. Results: The results of 23 patients (59%) were abnormal. Among them, 20 patients showed 74 focal lesions with an average of 3.7 per patient (15 studies performed within 3 months and 8 studies performed more than 3 months after injury). The remaining 3 showed diffuse hypoperfusion (two at the early stage and one at more than 3 months after the injury). The 13 abnormal studies performed at the early stage showed 58 lesions (average, 4.5 per patient), whereas there was a reduction to an average of 2.3 per patient in the 7 patients (total 16 lesions) at more than 3 months post-injury. In the 20 patients with focal lesions, mainly the following regions were involved: frontal lobes 43.2% (32/74), basal ganglia 24.3% (18/74) and temporal lobes 17.6% (13/74). Conclusions: 1) SPECT brain perfusion imaging is more sensitive than computed tomography in detecting brain lesions of mild traumatic brain injury. 2) SPECT brain perfusion imaging is more sensitive at early stage than at late stage after injury. 3) The most common complaints were headache, dizziness, memory deficit. The patients without loss of consciousness may present brain hypoperfusion, too. 4) The changes may explain a neurological component of the patient symptoms in

  7. Aid in the detection of myocardial perfusion abnormality utilizing SPECT atlas and images registration: preliminary results

    International Nuclear Information System (INIS)

    Padua, Rodrigo Donizete Santana de; Oliveira, Lucas Ferrari de; Marques, Paulo Mazzoncini de Azevedo; Groote, Jean-Jacques Georges Soares de; Castro, Adelson Antonio de; Ana, Lauro Wichert; Simoes, Marcus Vinicius

    2008-01-01

    To develop an atlas of myocardial perfusion scintigraphy and evaluating its applicability in computer-aided detection of myocardial perfusion defects in patients with ischemic heart disease. The atlas was created with rest-stress myocardial perfusion scintigraphic images of 20 patients of both genders with low probability of coronary artery disease and considered as normal by two experienced observers. Techniques of image registration and mathematical operations on images were utilized for obtaining template images depicting mean myocardial uptake and standard deviation for each gender and physiological condition. Myocardial perfusion scintigraphy images of one male and one female patient were aligned with the corresponding atlas template image, and voxels with myocardial uptake rates two standard deviations below the mean voxel value of the respective region in the atlas template image were highlighted on the tomographic sections and confirmed as perfusion defects by both observe. The present study demonstrated the creation of an atlas of myocardial perfusion scintigraphy with promising results of this tool as an aid in the detection of myocardial perfusion defects. However, further prospective validation with a more representative sample is recommended. (author)

  8. Aid in the detection of myocardial perfusion abnormality utilizing SPECT atlas and images registration: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Padua, Rodrigo Donizete Santana de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Div. de Cardiologia]. E-mail: rodrigo_dsp@hcrp.fmrp.usp.br; Oliveira, Lucas Ferrari de [Universidade Federal de Pelotas (UFPel), RS (Brazil). Inst. de Fisica e Matematica. Dept. de Tecnologia da Informacao; Marques, Paulo Mazzoncini de Azevedo [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Groote, Jean-Jacques Georges Soares de [Instituto de Ensino Superior COC, Ribeirao Preto, SP (Brazil). Lab. of Artifical Intelligence and Applications; Castro, Adelson Antonio de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP, (Brazil). Faculdade de Medicina; Ana, Lauro Wichert [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Simoes, Marcus Vinicius [Universidade de Sao Paulo (USP), Ribeirao Preto, SP, (Brazil). Faculdade de Medicina. Divisao de Cardiologia

    2008-11-15

    To develop an atlas of myocardial perfusion scintigraphy and evaluating its applicability in computer-aided detection of myocardial perfusion defects in patients with ischemic heart disease. The atlas was created with rest-stress myocardial perfusion scintigraphic images of 20 patients of both genders with low probability of coronary artery disease and considered as normal by two experienced observers. Techniques of image registration and mathematical operations on images were utilized for obtaining template images depicting mean myocardial uptake and standard deviation for each gender and physiological condition. Myocardial perfusion scintigraphy images of one male and one female patient were aligned with the corresponding atlas template image, and voxels with myocardial uptake rates two standard deviations below the mean voxel value of the respective region in the atlas template image were highlighted on the tomographic sections and confirmed as perfusion defects by both observe. The present study demonstrated the creation of an atlas of myocardial perfusion scintigraphy with promising results of this tool as an aid in the detection of myocardial perfusion defects. However, further prospective validation with a more representative sample is recommended. (author)

  9. Myocardial perfusion imaging by digital subtraction angiography

    International Nuclear Information System (INIS)

    Kadowaki, Hiroyuki; Ishikawa, Kinji; Ogai, Toshihiro; Katori, Ryo

    1986-01-01

    Several methods of digital subtraction angiography (DSA) were compared to determine which could better visualize regional myocardial perfusion using coronary angiography in seven patients with myocardial infarction, two with angina pectoris and five with normal coronary arteries. Satisfactory DSA was judged to be achieved if the shape of the heart on the mask film was identical to that on the live film and if both films were exactly superimposed. To obtain an identical mask film in the shape of each live film, both films were selected from the following three phases of the cardiac cycle; 1) at the R wave of the electrocardiogram, 2) 100 msec before the R wave, and 3) 200 msec before the R wave. The last two were superior for obtaining mask and live films which were similar in shape, because the cardiac motion in these phases was relatively small. Using these mask and live films, DSA was performed either with the continuous image mode (CI mode) or the time interval difference mode (TID mode). The overall perfusion of contrast medium through the artery to the vein was adequately visualized using the CI mode. Passage of contrast medium through the artery, capillary and vein was visualized at each phase using TID mode. Subtracted images were displayed and photographed, and the density of the contrast medium was adequate to display contour lines as in a relief map. Using this DSA, it was found that regional perfusion of the contrast medium was not always uniform in normal subjects, depending on the typography of the coronary artery. In all patients with anterior myocardial infarction, low perfusion was observed at the infarcted portion compared to the non-infarcted myocardium. In patients with inferior myocardial infarction, this low perfusion area was not observed because right coronary angiography was not subjected to DSA in this study. (J.P.N.)

  10. Myocardial CT perfusion imaging and SPECT for the diagnosis of coronary artery disease

    DEFF Research Database (Denmark)

    George, Richard T; Mehra, Vishal C; Chen, Marcus Y

    2014-01-01

    %, respectively, for SPECT. CONCLUSION: The overall performance of myocardial CT perfusion imaging in the diagnosis of anatomic CAD (stenosis ≥50%), as demonstrated with the Az, was higher than that of SPECT and was driven in part by the higher sensitivity for left main and multivessel disease.......PURPOSE: To compare the diagnostic performance of myocardial computed tomographic (CT) perfusion imaging and single photon emission computed tomography (SPECT) perfusion imaging in the diagnosis of anatomically significant coronary artery disease (CAD) as depicted at invasive coronary angiography....... MATERIALS AND METHODS: This study was approved by the institutional review board. Written informed consent was obtained from all patients. Sixteen centers enrolled 381 patients from November 2009 to July 2011. Patients underwent rest and adenosine stress CT perfusion imaging and rest and either exercise...

  11. Prediction of postoperative pulmonary function following thoracic operations. Value of ventilation-perfusion scanning

    International Nuclear Information System (INIS)

    Bria, W.F.; Kanarek, D.J.; Kazemi, H.

    1983-01-01

    Surgical resection of lung cancer is frequently required in patients with severely impaired lung function resulting from chronic obstructive pulmonary disease. Twenty patients with obstructive lung disease and cancer (mean preoperative forced expiratory volume in 1 second [FEV1] . 1.73 L) were studied preoperatively and postoperatively by spirometry and radionuclide perfusion, single-breath ventilation, and washout techniques to test the ability of these methods to predict preoperatively the partial loss of lung function by the resection. Postoperative FEV1 and forced vital capacity (FVC) were accurately predicted by the formula: postoperative FEV1 (or FVC) . preoperative FEV1 X percent function of regions of lung not to be resected (r . 0.88 and 0.95, respectively). Ventilation and perfusion scans are equally effective in prediction. Washout data add to the sophistication of the method by permitting the qualitative evaluation of ventilation during tidal breathing. Criteria for patients requiring the study are suggested

  12. In vivo MR perfusion imaging of renal artery stenosis

    International Nuclear Information System (INIS)

    Powers, T.; Lorenz, C.H.; Bain, R.; Holburn, G.; Price, R.R.

    1989-01-01

    Various techniques have been developed for noninvasive evaluation of renal blood flow. More important in the assessment of potential renal ischemia may be actual perfusion of the nephron mass. MR pulse sequences have been devised that allow perfusion imaging (PI) in a dog model of renal artery stenosis. Unilateral renal artery stenosis was created in mongrel dogs and quantitation of renal blood flow was obtained with radioactive microspheres. Perfusion imaging was performed on a 1.5-T system to obtain the apparent diffusion coefficient. During initial studies, it was found that the usual gradient factor used in brain PI was too high for renal studies; a factor of < 50 was found to be optimal. Additionally, respiratory gating with acquisition at end expiration was necessary to prevent renal motion. Recent studies have shown that PI reflects the asymmetry of flow in this model

  13. Acute cerebral stroke imaging and brain perfusion with the use of high-concentration contrast media

    Energy Technology Data Exchange (ETDEWEB)

    Miles, K.A. [Wesley Research Inst., The Wesley Hospital, Brisbane (Australia); Brighton and Sussex Medical School, Univ. of Sussex, Falmer, Brighton (United Kingdom)

    2003-12-01

    Acute cerebral stroke remains a major cause of death among adults and the emergence of new therapies has created a need for early and rapid imaging at a time when conventional CT is either normal or demonstrates subtle abnormalities that are easy to misinterpret. Perfusion CT uses the temporal changes in cerebral and blood attenuation during a rapid series of images acquired without table movement following an intravenous bolus of contrast medium to generate images of mean transit time (MTT) cerebral blood volume (CBV) and perfusion. Reduced perfusion with preserved CBV is indicative of reversible ischaemia, whereas a matched reduction in perfusion and CBV implies infarction. The CT perfusion imaging can positively identify patients with non-haemorrhagic stroke in the presence of a normal conventional CT, provide an indication as to prognosis and potentially select those patients for whom thrombolysis is appropriate. Perfusion CT offers a powerful adjunct to MDCT based imaging of cerebrovascular disease, but further clinical validation is required. (orig.)

  14. Dynamic CT perfusion imaging of the myocardium: a technical note on improvement of image quality.

    Directory of Open Access Journals (Sweden)

    Daniela Muenzel

    Full Text Available OBJECTIVE: To improve image and diagnostic quality in dynamic CT myocardial perfusion imaging (MPI by using motion compensation and a spatio-temporal filter. METHODS: Dynamic CT MPI was performed using a 256-slice multidetector computed tomography scanner (MDCT. Data from two different patients-with and without myocardial perfusion defects-were evaluated to illustrate potential improvements for MPI (institutional review board approved. Three datasets for each patient were generated: (i original data (ii motion compensated data and (iii motion compensated data with spatio-temporal filtering performed. In addition to the visual assessment of the tomographic slices, noise and contrast-to-noise-ratio (CNR were measured for all data. Perfusion analysis was performed using time-density curves with regions-of-interest (ROI placed in normal and hypoperfused myocardium. Precision in definition of normal and hypoperfused areas was determined in corresponding coloured perfusion maps. RESULTS: The use of motion compensation followed by spatio-temporal filtering resulted in better alignment of the cardiac volumes over time leading to a more consistent perfusion quantification and improved detection of the extend of perfusion defects. Additionally image noise was reduced by 78.5%, with CNR improvements by a factor of 4.7. The average effective radiation dose estimate was 7.1±1.1 mSv. CONCLUSION: The use of motion compensation and spatio-temporal smoothing will result in improved quantification of dynamic CT MPI using a latest generation CT scanner.

  15. Effect of Electrode Belt and Body Positions on Regional Pulmonary Ventilation- and Perfusion-Related Impedance Changes Measured by Electric Impedance Tomography.

    Directory of Open Access Journals (Sweden)

    Elin Ericsson

    Full Text Available Ventilator-induced or ventilator-associated lung injury (VILI/VALI is common and there is an increasing demand for a tool that can optimize ventilator settings. Electrical impedance tomography (EIT can detect changes in impedance caused by pulmonary ventilation and perfusion, but the effect of changes in the position of the body and in the placing of the electrode belt on the impedance signal have not to our knowledge been thoroughly evaluated. We therefore studied ventilation-related and perfusion-related changes in impedance during spontaneous breathing in 10 healthy subjects in five different body positions and with the electrode belt placed at three different thoracic positions using a 32-electrode EIT system. We found differences between regions of interest that could be attributed to changes in the position of the body, and differences in impedance amplitudes when the position of the electrode belt was changed. Ventilation-related changes in impedance could therefore be related to changes in the position of both the body and the electrode belt. Perfusion-related changes in impedance were probably related to the interference of major vessels. While these findings give us some insight into the sources of variation in impedance signals as a result of changes in the positions of both the body and the electrode belt, further studies on the origin of the perfusion-related impedance signal are needed to improve EIT further as a tool for the monitoring of pulmonary ventilation and perfusion.

  16. Correlation of iodine uptake and perfusion parameters between dual-energy CT imaging and first-pass dual-input perfusion CT in lung cancer.

    Science.gov (United States)

    Chen, Xiaoliang; Xu, Yanyan; Duan, Jianghui; Li, Chuandong; Sun, Hongliang; Wang, Wu

    2017-07-01

    To investigate the potential relationship between perfusion parameters from first-pass dual-input perfusion computed tomography (DI-PCT) and iodine uptake levels estimated from dual-energy CT (DE-CT).The pre-experimental part of this study included a dynamic DE-CT protocol in 15 patients to evaluate peak arterial enhancement of lung cancer based on time-attenuation curves, and the scan time of DE-CT was determined. In the prospective part of the study, 28 lung cancer patients underwent whole-volume perfusion CT and single-source DE-CT using 320-row CT. Pulmonary flow (PF, mL/min/100 mL), aortic flow (AF, mL/min/100 mL), and a perfusion index (PI = PF/[PF + AF]) were automatically generated by in-house commercial software using the dual-input maximum slope method for DI-PCT. For the dual-energy CT data, iodine uptake was estimated by the difference (λ) and the slope (λHU). λ was defined as the difference of CT values between 40 and 70 KeV monochromatic images in lung lesions. λHU was calculated by the following equation: λHU = |λ/(70 - 40)|. The DI-PCT and DE-CT parameters were analyzed by Pearson/Spearman correlation analysis, respectively.All subjects were pathologically proved as lung cancer patients (including 16 squamous cell carcinoma, 8 adenocarcinoma, and 4 small cell lung cancer) by surgery or CT-guided biopsy. Interobserver reproducibility in DI-PCT (PF, AF, PI) and DE-CT (λ, λHU) were relatively good to excellent (intraclass correlation coefficient [ICC]Inter = 0.8726-0.9255, ICCInter = 0.8179-0.8842; ICCInter = 0.8881-0.9177, ICCInter = 0.9820-0.9970, ICCInter = 0.9780-0.9971, respectively). Correlation coefficient between λ and AF, and PF were as follows: 0.589 (P input CT perfusion analysis method can be applied to assess blood supply of lung cancer patients. Preliminary results demonstrated that the iodine uptake relevant parameters derived from DE-CT significantly correlated with perfusion

  17. Lung inhalation scintigraphy with radioactive aerosols in several pulmonary diseases. Cintigrafia de ventialacao pulmonar por aerosol em diversas patologias pulmonares

    Energy Technology Data Exchange (ETDEWEB)

    Martins, L R; Marioni Filho, H [Instituto Dante Pazzanese de Cardiologia, Sao Paulo, SP (Brazil); Romaldini, H; Uehara, C; Alonso, G [Escola Paulista de Medicina, Sao Paulo, SP (Brazil)

    1983-01-01

    The pulmonary ventilation scintigraphy with 99m Tc diethylene-triamine-pentaacetate (99mTc-DTPA) delivered through a new nebulizer system when analyzed together with the classic lung perfusion scintigraphy with 99mTc-labeled albumin macroaggregates (99mTcMAA) is a very important diagnostic tool in several pulmonary diseases. Several aspects of the lung ventilation-perfusion scintigraphy are studied in 15 people with no lung disease, smokers and nonsmokers. The findings with the lung ventilation-perfusion scintigraphy are also discussed in 34 patients with several pulmonary diseases: lung cancer, chronic obstructive lung disease, policystic pulmonary disease, and pulmonary embolims. The authors concluded that the procedure is a valuable diagnostic tool in several pulmonary diseases, especially because good lung images are obtained, no side effects were detected, the technique is ease and low cost, and it brings new informations, not available with other diagnostic methods. (author).

  18. Perfusion MR imaging for differentiation of benign and malignant meningiomas

    NARCIS (Netherlands)

    Zhang, Hao; Rodiger, Lars A.; Shen, Tianzhen; Miao, Jingtao; Oudkerk, Matthijs

    Introduction Our purpose was to determine whether perfusion MR imaging can be used to differentiate benign and malignant meningiomas on the basis of the differences in perfusion of tumor parenchyma and/or peritumoral edema. Methods A total of 33 patients with preoperative meningiomas (25 benign and

  19. Rapid intravenous infusion of 20 mL/kg saline alters the distribution of perfusion in healthy supine humans.

    Science.gov (United States)

    Henderson, A C; Sá, R C; Barash, I A; Holverda, S; Buxton, R B; Hopkins, S R; Prisk, G K

    2012-03-15

    Rapid intravenous saline infusion, a model meant to replicate the initial changes leading to pulmonary interstitial edema, increases pulmonary arterial pressure in humans. We hypothesized that this would alter lung perfusion distribution. Six healthy subjects (29 ± 6 years) underwent magnetic resonance imaging to quantify perfusion using arterial spin labeling. Regional proton density was measured using a fast-gradient echo sequence, allowing blood delivered to the slice to be normalized for density and quantified in mL/min/g. Contributions from flow in large conduit vessels were minimized using a flow cutoff value (blood delivered > 35% maximum in mL/min/cm(3)) in order to obtain an estimate of blood delivered to the capillary bed (perfusion). Images were acquired supine at baseline, after infusion of 20 mL/kg saline, and after a short upright recovery period for a single sagittal slice in the right lung during breath-holds at functional residual capacity. Thoracic fluid content measured by impedance cardiography was elevated post-infusion by up to 13% (pchanges in conduit vessels, there were no significant changes in perfusion in dependent lung following infusion (7.8 ± 1.9 mL/min/g baseline, 7.9 ± 2.0 post, 8.5 ± 2.1 recovery, p=0.36). There were no significant changes in lung density. These data suggest that saline infusion increased perfusion to nondependent lung, consistent with an increase in intravascular pressures. Dependent lung may have been "protected" from increases in perfusion following infusion due to gravitational compression of the pulmonary vasculature. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Role of myocardial perfusion imaging in acute coronary syndrome

    International Nuclear Information System (INIS)

    Aleem, M.

    2007-01-01

    Full text: In the cardiac emergency department, a number of patients present with acute chest pain. In case of non diagnostic ECG and enzymes, accurately categorizing the patient in high and low probability is difficult. Aim of study was to evaluate the role of resting myocardial perfusion imaging (MPI) in patients with acute coronary syndrome (ACS) and then to compare the results with subsequent stress imaging. Material and Methods. A total of 34 patients were selected for the study, which were divided into three groups on the basis of respective probabilities of having ACS. This probability was decided on the basis of nature of chest pain, ECG findings, enzymes levels, and age and sex. Arbitrary score was given to patient's condition. This score ranged from 1 to 14. Patients with score between 1-6 were assigned low probability, from 7-10 were assigned intermediate probability and patients having score greater than 11 were placed in high probability groups. Patients in the low and intermediate probability groups were injected with Tc 99 m- MIBI within 6 hours of onset of chest pain and were undergone resting myocardial perfusion imaging (MPI) 3 to five hours after injection.. Imaging in high probability group was performed at discharge. Four weeks after the acute event all the patients underwent stress myocardial perfusion imaging. Results: All patients (100%) with low probability of ACS (n=10) showed negative resting scans. On stress MPI two patients (20%) showed new defects. Patient with high probability of ACS (n=12), all were positive 100% on resting MPI. On stress MPI, three showed (25%) no change from rest MPI, while nine patients (75%) showed augmentation of defects and four out of these nine patients (33%) also showed new perfusion defects. Patients with intermediate probability of ACS (n=12), three showed positive rest MPI (25%). On stress MPI out of these three cases, one showed (8%) no change from rest MPI and two showed (17%) augmentation of defect

  1. Modeling laser speckle imaging of perfusion in the skin (Conference Presentation)

    Science.gov (United States)

    Regan, Caitlin; Hayakawa, Carole K.; Choi, Bernard

    2016-02-01

    Laser speckle imaging (LSI) enables visualization of relative blood flow and perfusion in the skin. It is frequently applied to monitor treatment of vascular malformations such as port wine stain birthmarks, and measure changes in perfusion due to peripheral vascular disease. We developed a computational Monte Carlo simulation of laser speckle contrast imaging to quantify how tissue optical properties, blood vessel depths and speeds, and tissue perfusion affect speckle contrast values originating from coherent excitation. The simulated tissue geometry consisted of multiple layers to simulate the skin, or incorporated an inclusion such as a vessel or tumor at different depths. Our simulation used a 30x30mm uniform flat light source to optically excite the region of interest in our sample to better mimic wide-field imaging. We used our model to simulate how dynamically scattered photons from a buried blood vessel affect speckle contrast at different lateral distances (0-1mm) away from the vessel, and how these speckle contrast changes vary with depth (0-1mm) and flow speed (0-10mm/s). We applied the model to simulate perfusion in the skin, and observed how different optical properties, such as epidermal melanin concentration (1%-50%) affected speckle contrast. We simulated perfusion during a systolic forearm occlusion and found that contrast decreased by 35% (exposure time = 10ms). Monte Carlo simulations of laser speckle contrast give us a tool to quantify what regions of the skin are probed with laser speckle imaging, and measure how the tissue optical properties and blood flow affect the resulting images.

  2. Gray matter perfusion correlates with disease severity in ALS.

    Science.gov (United States)

    Rule, Randall R; Schuff, Norbert; Miller, Robert G; Weiner, Michael W

    2010-03-09

    The goal of this study is to determine if regional brain perfusion, as measured by arterial spin labeling (ASL) MRI, is correlated with clinical measures of amyotrophic lateral sclerosis (ALS) disease severity. The presence of such a relationship would indicate a possible role for ASL perfusion as a marker of disease severity and upper motor neuron involvement in ALS. Disease severity was assessed in 16 subjects with ALS (age 54 +/- 11) using the Amyotrophic Lateral Sclerosis Functional Rating Scale (ALSFRS) and the pulmonary function measure, forced vital capacity (FVC). Upper motor neuron involvement was assessed by testing rapid tapping of the fingers and feet. Magnetic resonance perfusion images were coregistered with structural T1-weighted MRI, corrected for partial volume effects using the structural images and normalized to a study-specific atlas. Correlations between perfusion and ALS disease severity were analyzed, using statistical parametric mapping, and including age as a factor. Analyses were adjusted for multiple clusters. ALS severity, as measured by the ALSFRS and FVC, was correlated with gray matter perfusion. This correlation was predominantly observed in the hemisphere contralateral to the more affected limbs. ALSFRS scores correlated with perfusion in the contralateral frontal and parietal lobe (p frontal lobe (p frontal lobe (p Upper motor neuron involvement, as measured by rapid finger tapping, correlated bilaterally with perfusion in the middle cingulate gyrus (p < 0.001). Amyotrophic lateral sclerosis (ALS) severity is correlated with brain perfusion as measured by arterial spin labeling (ASL) perfusion. This correlation appears to be independent of brain atrophy. ASL perfusion may be a useful tool for monitoring disease progression and assessing treatment effects in ALS.

  3. Arterial spin-labeling perfusion imaging of childhood meningitis: a case series.

    Science.gov (United States)

    Wong, Alex Mun-Ching; Yeh, Chih-Hua; Liu, Ho-Ling; Lin, Kuang-Lin; Wang, Huei-Shyong; Toh, Cheng-Hong

    2016-03-01

    Conventional magnetic resonance imaging (MRI), which is mainly used to detect complications, is ineffective in determining the neurological status of patients with meningitis. Hemodynamic change in the brain may be more indicative of the neurological status but few imaging studies have verified this. Arterial spin-labeling (ASL) perfusion, a noninvasive MR method requiring no contrast agent injection, can be used to measure cerebral blood flow (CBF). We describe three pediatric patients with meningitis, who all showed regions of increased CBF on perfusion imaging. One patient, presenting with headache and conscious disturbance, had CBF changes in the frontal, temporal, and occipital regions. The other two patients, presenting with hallucinations, memory deficits, and seizures, had CBF changes in the frontal and temporal regions. ASL perfusion imaging may be helpful in assessing patients with meningitis, demonstrating CBF changes more strongly correlating with the neurological status, and detecting active brain abnormalities.

  4. Pulmonary Perfusion Changes as Assessed by Contrast-Enhanced Dual-Energy Computed Tomography after Endoscopic Lung Volume Reduction by Coils.

    Science.gov (United States)

    Lador, Frédéric; Hachulla, Anne-Lise; Hohn, Olivia; Plojoux, Jérôme; Ronot, Maxime; Montet, Xavier; Soccal, Paola M

    2016-01-01

    Endoscopic lung volume reduction by coils (LVRC) is a recent treatment approach for severe emphysema. Furthermore, dual-energy computed tomography (DECT) now offers a combined assessment of lung morphology and pulmonary perfusion. The aim of our study was to assess the impact of LVRC on pulmonary perfusion with DECT. Seventeen patients (64.8 ± 6.7 years) underwent LVRC. DECT was performed prior to and after LVRC. For each patient, lung volumes and emphysema quantification were automatically calculated. Then, 6 regions of interest (ROIs) on the iodine perfusion map were drawn in the anterior, mid, and posterior right and left lungs at 4 defined levels. The ROI values were averaged to obtain lung perfusion as assessed by the lung's iodine concentration (CLung, μg·cm-3). The CLung values were normalized using the left atrial iodine concentration (CLA) to take into account differences between successive DECT scans. The 6-min walk distance (6MWD) improved significantly after the procedure (p = 0.0002). No lung volume changes were observed between successive DECT scans for any of the patients (p = 0.32), attesting the same suspended inspiration. After LVRC, the emphysema index was significantly reduced in the treated lung (p = 0.0014). Lung perfusion increased significantly adjacent to the treated areas (CLung/CLA from 3.4 ± 1.7 to 5.6 ± 2.2, p < 0.001) and in the ipsilateral untreated areas (from 4.1 ± 1.4 to 6.6 ± 1.7, p < 0.001), corresponding to a mean 65 and 61% increase in perfusion, respectively. No significant difference was observed in the contralateral upper and lower areas (from 4.4 ± 1.9 to 4.8 ± 2.1, p = 0.273, and from 4.9 ± 2.0 to 5.2 ± 1.7, p = 0.412, respectively). A significant correlation between increased 6MWD and increased perfusion was found (p = 0.0027, R2 = 0.3850). Quantitative analysis based on DECT acquisition revealed that LVRC results in a significant increase in perfusion in the coil-free areas adjacent to the treated ones, as

  5. Structural and perfusion magnetic resonance imaging of the lung in cystic fibrosis

    International Nuclear Information System (INIS)

    Amaxopoulou, Christina; Gnannt, Ralph; Kellenberger, Christian J.; Higashigaito, Kai; Jung, Andreas

    2018-01-01

    Because of its absence of ionising radiation and possibility for obtaining functional information, MRI is promising for assessing lung disease in children who require repetitive imaging for long-term follow-up. To describe MRI findings in children with cystic fibrosis and evaluate semi-quantitative dynamic contrast-enhanced lung perfusion. We retrospectively compared lung MRI in 25 children and young adults with cystic fibrosis (median age 3.7 years) to 12 children (median age 2 years) imaged for other pathologies. MRI at 1.5 T included respiratory-gated sequences and contrast-enhanced lung perfusion imaging. We described and graded any morphologic change. Signal enhancement and time to peak values of perfusion abnormalities were compared to those of normally enhancing lung parenchyma. Frequent findings in patients with cystic fibrosis were bronchial wall thickening (24/25, 96%), areas of consolidation (22/25, 88%), enlarged lymph nodes (20/25, 80%), bronchiectasis (5/25, 20%) and mucus plugging (3/25, 12%). Compared to normally enhancing lung, perfusion defects (21/25, 84%), characterised by decreased enhancement, showed prolonged time to peak. Areas of consolidation showed increased enhancement. While time to peak of procedure-related atelectasis was not significantly different from that of normal lung, disease-related consolidation showed prolonged time to peak (P=0.01). Lung MRI demonstrates structural and perfusion abnormalities in children and young people with cystic fibrosis. Semi-quantitative assessment of dynamic contrast-enhanced perfusion imaging might allow differentiation between procedure-related atelectasis and disease-related consolidation. (orig.)

  6. Structural and perfusion magnetic resonance imaging of the lung in cystic fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Amaxopoulou, Christina; Gnannt, Ralph; Kellenberger, Christian J. [University Children' s Hospital Zuerich, Department of Diagnostic Imaging, Zuerich, CH (Switzerland); University Children' s Hospital Zuerich, Children' s Research Center, Zuerich (Switzerland); Higashigaito, Kai [University Hospital Zuerich, Institute of Diagnostic and Interventional Radiology, Zuerich (Switzerland); Jung, Andreas [University Children' s Hospital Zuerich, Children' s Research Center, Zuerich (Switzerland); University Children' s Hospital Zuerich, Division of Pneumology, Zuerich (Switzerland)

    2018-02-15

    Because of its absence of ionising radiation and possibility for obtaining functional information, MRI is promising for assessing lung disease in children who require repetitive imaging for long-term follow-up. To describe MRI findings in children with cystic fibrosis and evaluate semi-quantitative dynamic contrast-enhanced lung perfusion. We retrospectively compared lung MRI in 25 children and young adults with cystic fibrosis (median age 3.7 years) to 12 children (median age 2 years) imaged for other pathologies. MRI at 1.5 T included respiratory-gated sequences and contrast-enhanced lung perfusion imaging. We described and graded any morphologic change. Signal enhancement and time to peak values of perfusion abnormalities were compared to those of normally enhancing lung parenchyma. Frequent findings in patients with cystic fibrosis were bronchial wall thickening (24/25, 96%), areas of consolidation (22/25, 88%), enlarged lymph nodes (20/25, 80%), bronchiectasis (5/25, 20%) and mucus plugging (3/25, 12%). Compared to normally enhancing lung, perfusion defects (21/25, 84%), characterised by decreased enhancement, showed prolonged time to peak. Areas of consolidation showed increased enhancement. While time to peak of procedure-related atelectasis was not significantly different from that of normal lung, disease-related consolidation showed prolonged time to peak (P=0.01). Lung MRI demonstrates structural and perfusion abnormalities in children and young people with cystic fibrosis. Semi-quantitative assessment of dynamic contrast-enhanced perfusion imaging might allow differentiation between procedure-related atelectasis and disease-related consolidation. (orig.)

  7. Pulmonary ventilation/perfusion scan

    Science.gov (United States)

    ... to stop eating (fast), be on a special diet, or take any medicines before the test. A chest x-ray is usually done before or after a ventilation and perfusion scan. You wear a hospital gown or comfortable clothing that does not have ...

  8. Analysis of decrease in lung perfusion blood volume with occlusive and non-occlusive pulmonary embolisms

    International Nuclear Information System (INIS)

    Ikeda, Yohei; Yoshimura, Norihiko; Hori, Yoshiro; Horii, Yosuke; Ishikawa, Hiroyuki; Yamazaki, Motohiko; Noto, Yoshiyuki; Aoyama, Hidefumi

    2014-01-01

    Highlights: • The proportion of preserved PE lesions in the non-occlusive group was 76.7% (33/43). • HUs of the iodine map were significantly higher in the non-occlusive group than in the occlusive group. • There was no significant difference in HUs between the non-occlusive and corresponding normal group. - Abstract: Purpose: The aim of this study was to determine if lung perfusion blood volume (lung PBV) with non-occlusive pulmonary embolism (PE) differs quantitatively and visually from that with occlusive PE and to investigate if lung PBV with non-occlusive PE remains the same as that without PE. Materials and methods: Totally, 108 patients suspected of having acute PE underwent pulmonary dual-energy computed tomography angiography (DECTA) between April 2011 and January 2012. Presence of PE on DECTA was evaluated by one radiologist. Two radiologists visually evaluated the PE distribution (segmental or subsegmental) and its nature (occlusive or non-occlusive) on DECTA and classified perfusion in lung PBV as “decreased,” “slightly decreased,” and “preserved”. Two radiologists used a lung PBV application to set a region of interest (ROI) in the center of the lesion and measured HU values of an iodine map. In the same slice as the ROI of the lesion and close to the lesion, another ROI was set in the normal perfusion area without PE, and HUs were measured. The proportion of lesions was compared between the occlusive and non-occlusive groups. HUs were compared among the occlusive, non-occlusive, and corresponding normal groups. Results: Twenty-five patients had 80 segmental or subsegmental lesions. There were 37 and 43 lesions in the occlusive and non-occlusive groups, respectively. The proportion of decreased lesions was 73.0% (27/37) in the occlusive group, while that of preserved lesions in the non-occlusive group was 76.7% (33/43). There was a significant difference in the proportion of lesions (P < 0.001) between the two groups. HUs of the

  9. Lung perfusion scintigraphy in congenital heart disease

    International Nuclear Information System (INIS)

    Sugimura, Hiroshi; Nagamachi, Shigeki; Hoshi, Hiroaki; Jinnouchi, Seishi; Oonishi, Takashi; Futami, Shigemi; Watanabe, Katsushi

    1990-01-01

    Lung perfusion scintigrams were reviewed retrospectively in 28 patients with congenital heart disease, whose ages ranged from the first year to 16 years with an average age of 5 years and 6 months. Seventy four MBq (2 mCi), 111 MBq (2 mCi), and 185 MBq (5 mCi) of Tc-99m macroaggregated albumin were iv injected in the age groups of 0-3, 4-11, and more than 11 years, respectively. Five minutes later, images were obtained in six projections. Abnormal findings on lung perfusion scintigrams were observed in 13 patients (46%). Of these patients, 8 (29%) had a partially decreased blood flow and 5 (17%) had a decreased blood flow in the unilateral lung. No significant difference in the occurrence of abnormal findings was observed among the age groups, although they tended to occur in younger patients. Sex, underlying conditions, and hemodynamics were also independent of scintigraphically abnormal findings. Even when classifying the patients as having either cyanotic or non-cyanotic heart disease, no significant difference in hemodynamics was observed between the group of abnormal findings and the group of normal findings. Pulmonary arteriography available in all patients failed to reveal abnormal findings, with the exception of pulmonary artery stenosis in 2 patients that corresponded to a decreased blood flow in the unilateral lung. Pulmonary artery stenosis seemed to be responsible for abnormal pulmonary blood flow, although other causes remained uncertain. (N.K.)

  10. Influence of vascular enhancement, age and gender on pulmonary perfused blood volume quantified by dual-energy-CTPA

    International Nuclear Information System (INIS)

    Meinel, Felix G.; Graef, Anita; Sommer, Wieland H.; Thierfelder, Kolja M.; Reiser, Maximilian F.; Johnson, Thorsten R.C.

    2013-01-01

    Objectives: To determine the influence of technical and demographic parameters on quantification of pulmonary perfused blood volume (PBV) in dual energy computed tomography pulmonary angiography (DE-CTPA). Materials and methods: Pulmonary PBV was quantified in 142 patients who underwent DE-CTPA for suspected pulmonary embolism but in whom no thoracic pathologies were detected. Multivariate linear regression analysis was performed to calculate the influence of age, gender, enhancement of pulmonary trunk and enhancement difference between pulmonary trunk and left atrium (as a measure of timing) on PBV values. The resulting regression coefficients were used to calculate age-specific ranges of normal for PBV values adjusted for vascular enhancement and timing. Results: Enhancement of the pulmonary trunk (β = −0.29, p = 0.001) and enhancement difference between pulmonary trunk and left atrium (β = −0.24, p = 0.003) were found to significantly influence PBV values. Age (β = −0.33, p < 0.001) but not gender (β = 0.14, p = 0.05) had a significant negative influence on pulmonary PBV values. There was a 20% relative decrease of pulmonary PBV from patients aged <30 to patients over 80 years of age. Conclusions: DE-CTPA derived PBV values need to be corrected for age, vascular enhancement and timing but not for gender. The age-specific ranges of normal derived from this study can be used as a reference in future studies of PBV in pulmonary pathologies

  11. Quantitative aspects of myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Vogel, R.A.

    1980-01-01

    Myocardial perfusion measurements have traditionally been performed in a quantitative fashion using application of the Sapirstein, Fick, Kety-Schmidt, or compartmental analysis principles. Although global myocardial blood flow measurements have not proven clinically useful, regional determinations have substantially advanced our understanding of and ability to detect myocardial ischemia. With the introduction of thallium-201, such studies have become widely available, although these have generally undergone qualitative evaluation. Using computer-digitized data, several methods for the quantification of myocardial perfusion images have been introduced. These include orthogonal and polar coordinate systems and anatomically oriented region of interest segmentation. Statistical ranges of normal and time-activity analyses have been applied to these data, resulting in objective and reproducible means of data evaluation

  12. ACR Appropriateness Criteria® Suspected Pulmonary Hypertension.

    Science.gov (United States)

    Sirajuddin, Arlene; Donnelly, Edwin F; Crabtree, Traves P; Henry, Travis S; Iannettoni, Mark D; Johnson, Geoffrey B; Kazerooni, Ella A; Maldonado, Fabien; Olsen, Kathryn M; Wu, Carol C; Mohammed, Tan-Lucien; Kanne, Jeffrey P

    2017-05-01

    Pulmonary hypertension may be idiopathic or related to a large variety of diseases. Various imaging examinations that may be helpful in diagnosing and determining the etiology of pulmonary hypertension are discussed. Imaging examinations that may aid in the diagnosis of pulmonary hypertension include chest radiography, ultrasound echocardiography, ventilation/perfusion scans, CT, MRI, right heart catheterization, pulmonary angiography, and fluorine-18-2-fluoro-2-deoxy-d-glucose PET/CT. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. Brain perfusion imaging using a Reconstruction-of-Difference (RoD) approach for cone-beam computed tomography

    Science.gov (United States)

    Mow, M.; Zbijewski, W.; Sisniega, A.; Xu, J.; Dang, H.; Stayman, J. W.; Wang, X.; Foos, D. H.; Koliatsos, V.; Aygun, N.; Siewerdsen, J. H.

    2017-03-01

    Purpose: To improve the timely detection and treatment of intracranial hemorrhage or ischemic stroke, recent efforts include the development of cone-beam CT (CBCT) systems for perfusion imaging and new approaches to estimate perfusion parameters despite slow rotation speeds compared to multi-detector CT (MDCT) systems. This work describes development of a brain perfusion CBCT method using a reconstruction of difference (RoD) approach to enable perfusion imaging on a newly developed CBCT head scanner prototype. Methods: A new reconstruction approach using RoD with a penalized-likelihood framework was developed to image the temporal dynamics of vascular enhancement. A digital perfusion simulation was developed to give a realistic representation of brain anatomy, artifacts, noise, scanner characteristics, and hemo-dynamic properties. This simulation includes a digital brain phantom, time-attenuation curves and noise parameters, a novel forward projection method for improved computational efficiency, and perfusion parameter calculation. Results: Our results show the feasibility of estimating perfusion parameters from a set of images reconstructed from slow scans, sparse data sets, and arc length scans as short as 60 degrees. The RoD framework significantly reduces noise and time-varying artifacts from inconsistent projections. Proper regularization and the use of overlapping reconstructed arcs can potentially further decrease bias and increase temporal resolution, respectively. Conclusions: A digital brain perfusion simulation with RoD imaging approach has been developed and supports the feasibility of using a CBCT head scanner for perfusion imaging. Future work will include testing with data acquired using a 3D-printed perfusion phantom currently and translation to preclinical and clinical studies.

  14. Fully automatic registration and segmentation of first-pass myocardial perfusion MR image sequences.

    Science.gov (United States)

    Gupta, Vikas; Hendriks, Emile A; Milles, Julien; van der Geest, Rob J; Jerosch-Herold, Michael; Reiber, Johan H C; Lelieveldt, Boudewijn P F

    2010-11-01

    Derivation of diagnostically relevant parameters from first-pass myocardial perfusion magnetic resonance images involves the tedious and time-consuming manual segmentation of the myocardium in a large number of images. To reduce the manual interaction and expedite the perfusion analysis, we propose an automatic registration and segmentation method for the derivation of perfusion linked parameters. A complete automation was accomplished by first registering misaligned images using a method based on independent component analysis, and then using the registered data to automatically segment the myocardium with active appearance models. We used 18 perfusion studies (100 images per study) for validation in which the automatically obtained (AO) contours were compared with expert drawn contours on the basis of point-to-curve error, Dice index, and relative perfusion upslope in the myocardium. Visual inspection revealed successful segmentation in 15 out of 18 studies. Comparison of the AO contours with expert drawn contours yielded 2.23 ± 0.53 mm and 0.91 ± 0.02 as point-to-curve error and Dice index, respectively. The average difference between manually and automatically obtained relative upslope parameters was found to be statistically insignificant (P = .37). Moreover, the analysis time per slice was reduced from 20 minutes (manual) to 1.5 minutes (automatic). We proposed an automatic method that significantly reduced the time required for analysis of first-pass cardiac magnetic resonance perfusion images. The robustness and accuracy of the proposed method were demonstrated by the high spatial correspondence and statistically insignificant difference in perfusion parameters, when AO contours were compared with expert drawn contours. Copyright © 2010 AUR. Published by Elsevier Inc. All rights reserved.

  15. Radioisotopic studies on pulmonary function in experimental burn shock

    International Nuclear Information System (INIS)

    Lambrecht, W.; Barcikowski, S.; Maziarz, Z.; Zajgner, J.; Markiewicz, A.

    1980-01-01

    Disturbances in pulmonary ventilation and perfusion, which can initiate severe complications, often lead to many therapeutic failures in burn shock. Early recognition of respiratory disturbances is often required to improve results of treatment of burn shock. The authors investigated changes in pulmonary ventilation and perfusion in napalm-burnt rabbits using 133 Xe. Simultaneously, they determined effect of treatment with cytochrome C on pulmonary ventilation and perfusion in animals burnt with napalm. It was found that in napalm-burnt rabbits burn shock was accompanied by a significant deterioration in pulmonary ventilation and perfusion. The most marked changes were observed one and two days after burn. It was also found a beneficial effect of treatment with cytochrome C on alveolar ventilation. The authors pointed out the usefulness of radioisotopic investigations of pulmonary ventilation and perfusion in burn shock. (author)

  16. Electrocardiographic left ventricular hypertrophy without echocardiographic abnormalities evaluated by myocardial perfusion and fatty acid metabolic imaging

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi

    2000-01-01

    The pathophysiologic process in patients with electrocardiographic left ventricular hypertrophy with ST, T changes but without echocardiographic abnormalities was investigated by myocardial perfusion imaging and fatty acid metabolic imaging. Exercise stress 99m Tc-methoxy-isobutyl isonitrile (MIBI) imaging and rest 123 I-beta-methyl-p-iodophenyl pentadecanoic acid (BMIPP) imaging were performed in 59 patients with electrocardiographic hypertrophy including 29 without apparent cause including hypertension and echocardiographic hypertrophy, and 30 with essential hypertension. Coronary angiography was performed in 6 patients without hypertension and 4 with hypertension and biopsy specimens were obtained from the left ventricular apex from 6 patients without hypertension. Myocardial perfusion and 123 I-BMIPP images were classified into 3 types: normal, increased accumulation of the isotope at the left ventricular apex (high uptake) and defect. Transient perfusion abnormality and apical defect observed by 123 I-BMIPP imaging were more frequent in patients without hypertension than in patients with hypertension (32% vs. 17%, p=0.04671 in perfusion; 62% vs. 30%, p=0.0236 in 123 I-BMIPP). Eighteen normotensive patients with apical defect by 123 I-BMIPP imaging included 3 of 10 patients with normal perfusion at exercise, 6 of 10 patients with high uptake and 9 of 9 patients with perfusion defect. The defect size revealed by 123 I-BMIPP imaging was greater than that of the perfusion abnormality. Coronary stenoses were not observed and myocardial specimens showed myocardial disarray with hypertrophy. Moreover, 9 patients with hypertension and apical defects by 123 I-BMIPP showed 3 different types of perfusion. Many patients without hypertension show a pathologic process similar to hypertrophic cardiomyopathy. Perfusion and 123 I-BMIPP imaging are useful for the identification of these patients. (author)

  17. Preoperative subtyping of meningiomas by perfusion MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hao [University Medical Center Groningen, University of Groningen (Netherlands); Shanghai Jiaotong University affiliated First People' s Hospital, Department of Radiology, Shanghai (China); Department of Radiology, University of Groningen (Netherlands); Roediger, Lars A.; Oudkerk, Matthijs [University Medical Center Groningen, University of Groningen (Netherlands); Department of Radiology, University of Groningen (Netherlands); Shen, Tianzhen [Fudan University Huashan Hospital, Department of Radiology, Shanghai (China); Miao, Jingtao [Shanghai Jiaotong University affiliated First People' s Hospital, Department of Radiology, Shanghai (China)

    2008-10-15

    This paper aims to evaluate the value of perfusion magnetic resonance (MR) imaging in the preoperative subtyping of meningiomas by analyzing the relative cerebral blood volume (rCBV) of three benign subtypes and anaplastic meningiomas separately. Thirty-seven meningiomas with peritumoral edema (15 meningothelial, ten fibrous, four angiomatous, and eight anaplastic) underwent perfusion MR imaging by using a gradient echo echo-planar sequence. The maximal rCBV (compared with contralateral normal white matter) in both tumoral parenchyma and peritumoral edema of each tumor was measured. The mean rCBVs of each two histological subtypes were compared using one-way analysis of variance and least significant difference tests. A p value less than 0.05 indicated a statistically significant difference. The mean rCBV of meningothelial, fibrous, angiomatous, and anaplastic meningiomas in tumoral parenchyma were 6.93{+-}3.75, 5.61{+-}4.03, 11.86{+-}1.93, and 5.89{+-}3.85, respectively, and in the peritumoral edema 0.87{+-}0.62, 1.38{+-}1.44, 0.87{+-}0.30, and 3.28{+-}1.39, respectively. The mean rCBV in tumoral parenchyma of angiomatous meningiomas and in the peritumoral edema of anaplastic meningiomas were statistically different (p<0.05) from the other types of meningiomas. Perfusion MR imaging can provide useful functional information on meningiomas and help in the preoperative diagnosis of some subtypes of meningiomas. (orig.)

  18. Perfusion magnetic resonance imaging provides additional information as compared to anatomical imaging for decision-making in vestibular schwannoma

    International Nuclear Information System (INIS)

    Kleijwegt, M.C.; Mey, A.G.L. van der; Wiggers-deBruine, F.T.; Malessy, M.J.A; Osch, M.J.P. van

    2016-01-01

    •DSC/ASL-MRI can be acquired in growing VS with sufficient image quality.•In most patients DSC and ASL techniques provide similar qualitative scores.•These techniques can be of importance in future decision-making. DSC/ASL-MRI can be acquired in growing VS with sufficient image quality. In most patients DSC and ASL techniques provide similar qualitative scores. These techniques can be of importance in future decision-making. The added value of perfusion MRI for decision-making in vestibular schwannoma (VS) patients is unknown. MRI offers two perfusion methods: the first employing contrast agent (dynamic susceptibility contrast (DSC)-MRI) that provides information on cerebral blood volume (CBV) and cerebral blood flow (CBF), the second by magnetic labeling of blood (arterial spin labeling (ASL)-MRI), providing CBF-images. The goal of the current study is to investigate whether DSC and ASL perfusion MRI provides complimentary information to current anatomical imaging in treatment selection process of VS. Nine patients with growing VS with extrameatal diameter >9 mm were included (>2 mm/year and 20% volume expansion/year) and one patient with 23 mm extrameatal VS without growth. DSC and ASL perfusion MRI were obtained on 3 T MRI. Perfusion in VS was scored as hyperintense, hypointense or isointense compared to the contralateral region. Seven patients showed hyperintense signal on DSC and ASL sequences. Three patients showed iso- or hypointense signal on at least one perfusion map (1 patient hypointense on both DSC-MRI and ASL; 1 patient isointense on DSC-CBF; 1 patient isointense on ASL). All patients showed enhancement on post-contrast T1 anatomical scan. Perfusion MR provides additional information compared to anatomical imaging for decision-making in VS

  19. Rest-Stress Limb Perfusion Imaging in Humans with Contrast Ultrasound Using Intermediate-Power Imaging and Microbubbles Resistant to Inertial Cavitation.

    Science.gov (United States)

    Davidson, Brian P; Hodovan, James; Belcik, J Todd; Moccetti, Federico; Xie, Aris; Ammi, Azzdine Y; Lindner, Jonathan R

    2017-05-01

    Contrast-enhanced ultrasound (CEU) limb perfusion imaging is a promising approach for evaluating peripheral artery disease (PAD). However, low signal enhancement in skeletal muscle has necessitated high-power intermittent imaging algorithms, which are not clinically feasible. We hypothesized that CEU using a combination of intermediate power and a contrast agent resistant to inertial cavitation would allow real-time limb stress perfusion imaging. In normal volunteers, CEU of the calf skeletal muscle was performed on separate days with Sonazoid, Optison, or Definity. Progressive reduction in the ultrasound pulsing interval was used to assess the balance between signal enhancement and agent destruction at escalating mechanical indices (MI, 0.1-0.4). Real-time perfusion imaging at MI 0.1-0.4 using postdestructive replenishment kinetics was performed at rest and during 25 W plantar flexion contractile exercise. For Optison, limb perfusion imaging was unreliable at rest due to very low signal enhancement generated at all MIs and was possible during exercise-induced hyperemia only at MI 0.1 due to agent destruction at higher MIs. For Definity, signal intensity progressively increased with MI but was offset by microbubble destruction, which resulted in modest signal enhancement during CEU perfusion imaging and distortion of replenishment curves at MI ≥ 0.2. For Sonazoid, there strong signal enhancement at MI ≥ 0.2, with little destruction detected only at MI 0.4. Accordingly, high signal intensity and nondistorted perfusion imaging was possible at MI 0.2-0.3 and detected an 8.0- ± 5.7-fold flow reserve. Rest-stress limb perfusion imaging in humans with real-time CEU, which requires only seconds to perform, is possible using microbubbles with viscoelastic properties that produce strong nonlinear signal generation without destruction at intermediate acoustic pressures. Copyright © 2016 American Society of Echocardiography. All rights reserved.

  20. Imaging method in the diagnosis of pulmonary thromboembolism

    International Nuclear Information System (INIS)

    Medaglia Monge, Luis Gerardo

    2011-01-01

    Pulmonary thromboembolism has been a common cause of morbidity and mortality. The same has become the third cause of acute cardiovascular disease after acute myocardial infarction and cerebral vascular accident which has produced thousands of deaths per year. Two large multicenter studies have found that although it was reported a mortality rate of up to 50-58% in patients with hemodynamic compromise, even at hemodynamically stable patients the mortality rate varied from 8-15%. Studies of autopsy have shown that up to 10% of the intrahospital deaths are secondary to pulmonary thromboembolism, despite its high incidence have been difficult to diagnose. Within the diagnostic arsenal that has accounted this entity are found: the clinical assessment, laboratory tests such as D dimer, ventilation-perfusion scintigraphy, venous Doppler U.S. of the lower limbs, pulmonary angiography and computed tomography angiography. Helical computed tomography angiography has offered, in daily clinical practice, the first line study in patients with suspected pulmonary thromboembolism, this happens at the end of the decade of the eighties. The computed tomography angiography has offered many advantages with respect to its competitors including availability, cost-benefit, volumetric image acquisition, and with the reconstruction resulting, identification of alternative diagnoses, the ability of valuation of pelvic veins and inferior limbs at the same time and good interobserver concordance. Computed tomography has revolutionized radiology and medicine, it has been noninvasive diagnostic technique of great power that is in continuous development. This technique by its high spatial and temporal resolution to study virtually any organ and has replaced other techniques previously established in the diagnostic algorithms. The benefits of the technique have been clear but is not without limitations. Computed tomography studies should be performed only when they are clinically justified and

  1. Image quality in CT perfusion imaging of the brain. The role of iodine concentration

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, Matthias; Bueltmann, Eva; Bode-Schnurbus, Lucas; Koenen, Dirk; Mielke, Eckhart; Heuser, Lothar [Knappschaftskrankenhaus Langendreer, Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Ruhr-University Bochum, Bochum (Germany)

    2007-01-15

    The purpose of this study was to evaluate the impact of various iodine contrast concentrations on image quality in computed tomography (CT) perfusion studies. Twenty-one patients with suspicion of cerebral ischemia underwent perfusion CT using two different iodine contrast concentrations: 11 patients received iomeprol 300 (iodine concentration: 300 mg/ml) while ten received the same volume of iomeprol 400 (iodine concentration: 400 mg/ml). Scan parameters were kept constant for both groups. Maps of cerebral blood flow (CBF), cerebral blood volume (CBV), and time to peak (TTP) were calculated from two adjacent slices. Quantitative comparisons were based on measurements of the maximum enhancement [Hounsfield units (HU)] and signal-to-noise index (SNI) on CBF, CBV, and TTP images. Determinations of grey-to-white-matter delineation for each iodine concentration were performed by two blinded readers. Only data from the non-ischemic hemispheres were considered. Both maximum enhancement and SNI values were higher after iomeprol 400, resulting in significantly better image quality in areas of low perfusion. No noteworthy differences were found for normal values of CBF, CBV, and TTP. Qualitative assessment of grey/white matter contrast on CBF and CBV maps revealed better performance for iomeprol 400. For brain perfusion studies, highly concentrated contrast media such as iomeprol 400 is superior to iomeprol 300. (orig.)

  2. Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Eun Jung; Cho, Ihn Ho [Yeungnam University Hospital, Daegu (Korea, Republic of); Kang, Won Jun [Yonsei University Hospital, Seoul (Korea, Republic of); Kim, Seong Min [Chungnam National University Medical School and Hospital, Daejeon (Korea, Republic of); Won, Kyoung Sook [Keomyung University Dongsan Hospital, Daegu (Korea, Republic of); Lim, Seok Tae [Chonbuk National University Medical School and Hospital, Jeonju (Korea, Republic of); Hwang, Kyung Hoon [Gachon University Gil Hospital, Incheon (Korea, Republic of); Lee, Byeong Il; Bom, Hee Seung [Chonnam National University Medical School and Hospital, Gwangju (Korea, Republic of)

    2009-12-15

    Integration of the functional information of myocardial perfusion SPECT (MPS) and the morphoanatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Forty-eight patients (M:F=26:22, Age: 63.3{+-}10.4 years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

  3. Pulmonary abnormalities in mitral valve disease. Comparison between pulmonary wedge pressure, regional pulmonary blood flow and chest films

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, L H; Andersen, Jr, P E [Odense Univ. (Denmark)

    1978-01-01

    Chest films, right sided heart catheterization, and measurement of the regional lung perfusion, using /sup 133/Xe, were carried out 31 times on patients with mitral valve disease. A relationship was found between the radiologic evaluation in 3 grades, and the values of pulmonary wedge pressure and the apical and basal perfusion. Changes in flow distribution as reflected in altered appearance of the vessels and the presence of interstitial edema were found to be the most sensitive factors in the evaluation of pulmonary wedge pressure. Chest radiography was thus found suitable for the evaluation of pulmonary wedge pressure in mitral valve disease.

  4. Spatio-temporal analysis of blood perfusion by imaging photoplethysmography

    Science.gov (United States)

    Zaunseder, Sebastian; Trumpp, Alexander; Ernst, Hannes; Förster, Michael; Malberg, Hagen

    2018-02-01

    Imaging photoplethysmography (iPPG) has attracted much attention over the last years. The vast majority of works focuses on methods to reliably extract the heart rate from videos. Only a few works addressed iPPGs ability to exploit spatio-temporal perfusion pattern to derive further diagnostic statements. This work directs at the spatio-temporal analysis of blood perfusion from videos. We present a novel algorithm that bases on the two-dimensional representation of the blood pulsation (perfusion map). The basic idea behind the proposed algorithm consists of a pairwise estimation of time delays between photoplethysmographic signals of spatially separated regions. The probabilistic approach yields a parameter denoted as perfusion speed. We compare the perfusion speed versus two parameters, which assess the strength of blood pulsation (perfusion strength and signal to noise ratio). Preliminary results using video data with different physiological stimuli (cold pressure test, cold face test) show that all measures are influenced by those stimuli (some of them with statistical certainty). The perfusion speed turned out to be more sensitive than the other measures in some cases. However, our results also show that the intraindividual stability and interindividual comparability of all used measures remain critical points. This work proves the general feasibility of employing the perfusion speed as novel iPPG quantity. Future studies will address open points like the handling of ballistocardiographic effects and will try to deepen the understanding of the predominant physiological mechanisms and their relation to the algorithmic performance.

  5. Mouse myocardial first-pass perfusion MR imaging

    NARCIS (Netherlands)

    Coolen, Bram F.; Moonen, Rik P. M.; Paulis, Leonie E. M.; Geelen, Tessa; Nicolay, Klaas; Strijkers, Gustav J.

    2010-01-01

    A first-pass myocardial perfusion sequence for mouse cardiac MRI is presented. A segmented ECG-triggered acquisition combined with parallel imaging acceleration was used to capture the first pass of a Gd-DTPA bolus through the mouse heart with a temporal resolution of 300-400 msec. The method was

  6. Noninvasive quantification of myocardial perfusion heterogeneity by Markovian analysis in SPECT nuclear imaging

    International Nuclear Information System (INIS)

    Pons, G.

    2011-01-01

    Cardiovascular diseases are the leading cause of mortality worldwide, and third of these deaths are caused by coronary artery disease and rupture of vulnerable atherosclerotic plaques. The heterogeneous alteration of the coronary microcirculation is an early phenomenon associated with many cardiovascular risk factors that can strongly predict the subsequent development of coronary artery disease, and lead to the appearance of myocardial perfusion heterogeneity. Nuclear medicine allows the study of myocardial perfusion in clinical routine through scintigraphic scans performed after injection of a radioactive tracer of coronary blood flow. Analysis of scintigraphic perfusion images currently allows the detection of myocardial ischemia, but the ability of the technique to measure the perfusion heterogeneity in apparently normally perfused areas is unknown. The first part of this thesis focuses on a retrospective clinical study to determine the feasibility of myocardial perfusion heterogeneity quantification measured by Thallium-201 single photon emission computed tomography (SPECT) in diabetic patients compared with healthy subjects. The clinical study has demonstrated the ability of routine thallium-201 SPECT imaging to quantify greater myocardial perfusion heterogeneity in diabetic patients compared with normal subjects. The second part of this thesis tests the hypothesis that the myocardial perfusion heterogeneity could be quantified in small animal SPECT imaging by Thallium-201 and/or Technetium-99m-MIBI in an experimental study using two animal models of diabetes, and is correlated with histological changes. The lack of difference in myocardial perfusion heterogeneity between control and diabetic animals suggests that animal models are poorly suited, or that the technology currently available does not seem satisfactory to obtain similar results as the clinical study. (author)

  7. The alphabet soup of perfusion CT and MR imaging: terminology revisited and clarified in five questions

    International Nuclear Information System (INIS)

    Leiva-Salinas, Carlos; Provenzale, James M.; Kudo, Kohsuke; Sasaki, Makoto; Wintermark, Max

    2012-01-01

    The five questions answered in this article revolve around the different parameters resulting from perfusion imaging processing, and this clarifies the frequently confusing terminology used to describe these parameters. More specifically, the article discusses the different imaging techniques and main mathematical models behind perfusion imaging, reviews the perfusion attributes of brain tissue, and proposes a standardized parameter terminology to facilitate understanding and avoid common misinterpretations. (orig.)

  8. The alphabet soup of perfusion CT and MR imaging: terminology revisited and clarified in five questions

    Energy Technology Data Exchange (ETDEWEB)

    Leiva-Salinas, Carlos [University of Virginia, Department of Radiology, Neuroradiology Division, Charlottesville, VA (United States); Hospital Universitario y Politecnico la Fe, Department of Radiology, Neuroradiology Division, Valencia (Spain); Universidad Autonoma de Barcelona, Department of Medicine, Barcelona (Spain); Provenzale, James M. [Duke University Medical Center, Department of Radiology, Durham, NC (United States); Emory University School of Medicine, Departments of Radiology, Oncology and Biomedical Engineering, Atlanta, GA (United States); Kudo, Kohsuke; Sasaki, Makoto [Iwate Medical University, Division of Ultra-high Field MRI, Institute for Biomedical Sciences, Morioka (Japan); Wintermark, Max [University of Virginia, Department of Radiology, Neuroradiology Division, Charlottesville, VA (United States); University of Virginia Medical Center, Department of Radiology, Neuroradiology Division, 1215 Lee Street-New Hospital, 1st Floor, Room 1011, PO Box 800170, Charlottesville, VA (United States)

    2012-09-15

    The five questions answered in this article revolve around the different parameters resulting from perfusion imaging processing, and this clarifies the frequently confusing terminology used to describe these parameters. More specifically, the article discusses the different imaging techniques and main mathematical models behind perfusion imaging, reviews the perfusion attributes of brain tissue, and proposes a standardized parameter terminology to facilitate understanding and avoid common misinterpretations. (orig.)

  9. Perfusion-weighted MR imaging in persistent hemiplegic migraine

    Energy Technology Data Exchange (ETDEWEB)

    Mourand, Isabelle; Menjot de Champfleur, Nicolas; Carra-Dalliere, Clarisse; Le Bars, Emmanuelle; Bonafe, Alain; Thouvenot, Eric [Hopital Gui de Chauliac, Service de Neuroradiologie, Montpellier (France); Roubertie, Agathe [Hopital Gui de Chauliac, Service de Neuropediatrie, Montpellier (France)

    2012-03-15

    Hemiplegic migraine is a rare type of migraine that has an aura characterized by the presence of motor weakness, which may occasionally last up to several days, and then resolve without sequela. Pathogenesis of migraine remains unclear and, recently, perfusion-weighted imaging (PWI) has provided a non-invasive method to study hemodynamic changes during acute attacks. Two female patients were admitted in our hospital suffering from prolonged hemiparesis. In both cases, they underwent MRI examination using a 1.5 T magnet including axial diffusion-weighted and perfusion sequences. From each perfusion MRI acquisition two regions of interest were delineated on each hemisphere and, the index of flow, cerebral blood volume, mean transit time, and time to peak were recorded and asymmetry indices from each perfusion parameter were calculated. Perfusion alterations were detected during the attacks. In one case, we observed, after 3 h of left hemiparesia, hypoperfusion of the right hemisphere. In the other case, who presented a familial hemiplegic migraine attack, on the third day of a persistent aura consisting of right hemiplegia and aphasia, PWI revealed hyperperfusion of the left hemisphere. Asymmetry indices for temporal parameters (mean transit time and time to peak) were the most sensitive. These findings resolved spontaneously after the attacks without any permanent sequel or signs of cerebral ischemia on follow-up MRI. PWI should be indicated for patients with migraine attacks accompanied by auras to assess the sequential changes in cerebral perfusion and to better understand its pathogenesis. (orig.)

  10. Perfusion-weighted MR imaging in persistent hemiplegic migraine

    International Nuclear Information System (INIS)

    Mourand, Isabelle; Menjot de Champfleur, Nicolas; Carra-Dalliere, Clarisse; Le Bars, Emmanuelle; Bonafe, Alain; Thouvenot, Eric; Roubertie, Agathe

    2012-01-01

    Hemiplegic migraine is a rare type of migraine that has an aura characterized by the presence of motor weakness, which may occasionally last up to several days, and then resolve without sequela. Pathogenesis of migraine remains unclear and, recently, perfusion-weighted imaging (PWI) has provided a non-invasive method to study hemodynamic changes during acute attacks. Two female patients were admitted in our hospital suffering from prolonged hemiparesis. In both cases, they underwent MRI examination using a 1.5 T magnet including axial diffusion-weighted and perfusion sequences. From each perfusion MRI acquisition two regions of interest were delineated on each hemisphere and, the index of flow, cerebral blood volume, mean transit time, and time to peak were recorded and asymmetry indices from each perfusion parameter were calculated. Perfusion alterations were detected during the attacks. In one case, we observed, after 3 h of left hemiparesia, hypoperfusion of the right hemisphere. In the other case, who presented a familial hemiplegic migraine attack, on the third day of a persistent aura consisting of right hemiplegia and aphasia, PWI revealed hyperperfusion of the left hemisphere. Asymmetry indices for temporal parameters (mean transit time and time to peak) were the most sensitive. These findings resolved spontaneously after the attacks without any permanent sequel or signs of cerebral ischemia on follow-up MRI. PWI should be indicated for patients with migraine attacks accompanied by auras to assess the sequential changes in cerebral perfusion and to better understand its pathogenesis. (orig.)

  11. Mouse myocardial first-pass perfusion MR imaging

    NARCIS (Netherlands)

    Coolen, B.F.; Moonen, R.P.M.; Paulis, L.E.M.; Geelen, T.; Nicolay, K.; Strijkers, G.J.

    2010-01-01

    A first-pass myocardial perfusion sequence for mouse cardiac MRI is presented. A segmented ECG-triggered acquisition combined with parallel imaging acceleration was used to capture the first pass of a Gd-DTPA bolus through the mouse heart with a temporal resolution of 300–400 msec. The method was

  12. A comparative study of MR imaging scores and MR perfusion imaging in pre-operative grading of intracranial gliomas

    International Nuclear Information System (INIS)

    Wu Honglin; Chen Junkun; Zhang Zongjun; Lu Guangming; Chen Ziqian; Wang Wei; Ji Xueman; Tang Xiaojun; Li Lin

    2005-01-01

    Objective: To compare the accuracy of MR imaging scores with MR perfusion imaging in pre-operative grading of intracranial gliomas. Methods: Thirty patients with intracranial gliomas (8 low-grade and 22 high-grade, according to WHO criteria) were examined with MR perfusion imaging pre-operatively. The lesions were evaluated by using an MR imaging score based on nine criteria. rCBV of the lesions were calculated by comparing the CBV of the lesion and that of contralateral normal white matter. The scores and ratios in high-grade and low-grade tumours were compared. Results: The MR imaging score of low grade (grades I and II) gliomas (0.67±0.29) were significantly lower than that of grades III (1.32 ± 0.47) (t=-3.48, P=0.003) and IV (1.56 ± 0.20) (t=-7.36, P=0.000) gliomas. There was no statistical difference when MR imaging scores of grades III and IV gliomas (t=-1.39, P=0.182) were compared. The maximum rCBV ratio of low grade (grades I and II) gliomas (2.38 ± 0.66 ) were significantly lower than that of grades III (5.81 ± 3.20) (t=-3.57, P=0.003) and IV (6.99 ± 2.47) (t=-5.09, P=0.001). There was no statistical difference when rCBV ratios of grades III and IV (t =-0.93, P=0.365) gliomas were compared. The accuracy of MR imaging scores in the noninvasive grading of untreated gliomas was all most the same as that of MR perfusion imaging (90.00% vs 89.29%). Conclusion: The MR imaging scores and MR perfusion imaging are two very useful tools in the evaluation of the histopathologic grade of cerebral gliomas. The overall accuracy in the noninvasive grading of gliomas may be imp roved if MR imaging scores and MR perfusion imaging are combined. (authors)

  13. Analysis of perfusion weighted image of CNS lymphoma

    International Nuclear Information System (INIS)

    Lee, In Ho; Kim, Sung Tae; Kim, Hyung-Jin; Kim, Keon Ha; Jeon, Pyoung; Byun, Hong Sik

    2010-01-01

    Purpose: It is difficult to differentiate CNS lymphoma from other tumors such as malignant gliomas, metastases, or meningiomas with conventional MR imaging, because the imaging findings are overlapped between these tumors. The purpose of this study is to investigate the perfusion weighted MR imaging findings of CNS lymphomas and to compare the relative cerebral blood volume ratios between CNS lymphomas and other tumors such as high grade gliomas, metastases, or meningiomas. Materials and methods: We retrospectively reviewed MRI findings and clinical records in 13 patients with pathologically proven CNS lymphoma between January 2006 and November 2008. We evaluated the relative cerebral blood volume ratios of tumor, which were obtained by dividing the values obtained from the normal white matter on MRI. Results: Total 13 patients (M:F = 8:5; age range 46-67 years, mean age 52.3 years) were included. The CNS lymphomas showed relatively low values of maximum relative CBV ratio in most patients regardless of primary or secondary CNS lymphoma. Conclusion: Perfusion weighted image may be helpful in the diagnosis of CNS lymphoma in spite of primary or secondary or B cell or T cell.

  14. Paradoxical perfusion metrics of high-grade gliomas with an oligodendroglioma component: quantitative analysis of dynamic susceptibility contrast perfusion MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sunwoo, Leonard; Park, Sun-Won [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul Metropolitan Government - Seoul National University Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of); Choi, Seung Hong [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University, Center for Nanoparticle Research, Institute for Basic Science, and School of Chemical and Biological Engineering, Seoul (Korea, Republic of); Yoo, Roh-Eul; Kang, Koung Mi; Yun, Tae Jin; Kim, Ji-hoon; Sohn, Chul-Ho [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Kim, Tae Min; Lee, Se-Hoon [Seoul National University Hospital, Department of Internal Medicine, Seoul (Korea, Republic of); Park, Chul-Kee [Seoul National University Hospital, Department of Neurosurgery, Seoul (Korea, Republic of); Won, Jae-Kyung; Park, Sung-Hye [Seoul National University Hospital, Department of Pathology, Seoul (Korea, Republic of); Kim, Il Han [Seoul National University Hospital, Department of Radiation Oncology, Seoul (Korea, Republic of)

    2015-11-15

    The aim of this study is to investigate perfusion characteristics of glioblastoma with an oligodendroglioma component (GBMO) compared with conventional glioblastoma (GBM) using dynamic susceptibility contrast (DSC) perfusion magnetic resonance (MR) imaging and microvessel density (MVD). The study was approved by the institutional review board. Newly diagnosed high-grade glioma patients were enrolled (n = 72; 20 GBMs, 14 GBMOs, 19 anaplastic astrocytomas (AAs), 13 anaplastic oligodendrogliomas (AOs), and six anaplastic oligoastrocytomas (AOAs)). All participants underwent preoperative MR imaging including DSC perfusion MR imaging. Normalized cerebral blood volume (nCBV) values were analyzed using a histogram approach. Histogram parameters were subsequently compared across each tumor subtype and grade. MVD was quantified by immunohistochemistry staining and correlated with perfusion parameters. Progression-free survival (PFS) was assessed according to the tumor subtype. GBMO displayed significantly reduced nCBV values compared with GBM, whereas grade III tumors with oligodendroglial components (AO and AOA) exhibited significantly increased nCBV values compared with AA (p < 0.001). MVD analyses revealed the same pattern as nCBV results. In addition, a positive correlation between MVD and nCBV values was noted (r = 0.633, p < 0.001). Patients with oligodendroglial tumors exhibited significantly increased PFS compared with patients with pure astrocytomas in each grade. In contrast to grade III tumors, the presence of oligodendroglial components in grade IV tumors resulted in paradoxically reduced perfusion metrics and MVD. In addition, patients with GBMO exhibited a better clinical outcome compared with patients with GBM. (orig.)

  15. Information content of pulmonary perfusion scintigraphy

    International Nuclear Information System (INIS)

    Kunieda, Takeyoshi

    1982-01-01

    A scinticamera computer system was used to measure the distribution of blood flow in both upright and supine lungs sequentially with the same counting geometry. The counting ratio of the upper half to the lower half lung, and the difference of distribution indices between supine lung and upright lung which is the fraction of postural change from the supine upper half to upright lower half lung to total distribution of blood flow, were referred to as ''U/L ratio'' and postural ''Change of Distribution'' respectively. U/L ratio correlated well with left atrial mean pressure (r = 0.87, p < 0.001) with the regression equation and Change of Distribution correlated well with pulmonary artery mean pressure (PAm) (r = -0.88, p < 0.001) in cardiac diseases. The relationship between the Change of Distribution and PAm was investigated using various regression analyses and the best fit was obtained by logarithmic regression (r = -0.92) with the regression equation. This regression equation means that there is no change of distribution of pulmonary blood flow with pulmonary artery pressure over 58 mmHg and that entire pulmonary blood flow comes to the lower half lung when the pulmonary artery pressure decreases to zero level. Pulmonary parenchymal and vascular disorders including primary pulmonary hypertension also held the same relationship with PAm. The relationship between upright U/L ratio and postural Change of Distribution permitted differentiation between precapillary pulmonary hypertension and postcapillary pulmonary hypertension. (J.P.N.)

  16. Simultaneous maximal exercise radionuclide angiography and thallium stress perfusion imaging

    International Nuclear Information System (INIS)

    Narahara, K.A.; Mena, I.; Maublant, J.C.; Brizendine, M.; Criley, J.M.

    1984-01-01

    Gold-195m is a new ultra-short-lived radionuclide that can be used for cardiac studies. Accurate, reproducible ejection fraction and ventricular wall motion studies can be obtained from first-transit angiography using commercially available imaging and image-processing equipment. The short half-life of gold-195m (30.5 seconds) makes simultaneous dual isotope imaging possible and substantially reduces the radiation exposure from the isotope angiography. The feasibility and possible benefits of performing dual radionuclide studies were evaluated during a single exercise stress test in 24 subjects with known coronary artery disease (CAD) and in 20 normal volunteers. High-quality first-transit angiograms were obtained in all subjects. An 83% sensitivity and 95% specificity for detecting CAD with thallium-201 imaging was noted in this investigation, suggesting that its diagnostic accuracy was not altered by simultaneous dual isotone imaging. When segmental left ventricular (LV) wall motion was compared with thallium-201 perfusion imaging, divergent results were noted in 15 of 44 subjects. An analysis of the ejection fraction (EF) results at rest and stress provided additional information that could be useful in assessing the clinical significance of such differences in segmental wall motion and perfusion. Simultaneous dual isotope imaging appears to be appropriate for situations in which both LV perfusion and function require evaluation. The use of gold-195m allows such information to be obtained from a single exercise test and can thereby reduce the cost and time required for noninvasive evaluations of patients for CAD

  17. Computed tomography perfusion imaging denoising using Gaussian process regression

    International Nuclear Information System (INIS)

    Zhu Fan; Gonzalez, David Rodriguez; Atkinson, Malcolm; Carpenter, Trevor; Wardlaw, Joanna

    2012-01-01

    Brain perfusion weighted images acquired using dynamic contrast studies have an important clinical role in acute stroke diagnosis and treatment decisions. However, computed tomography (CT) images suffer from low contrast-to-noise ratios (CNR) as a consequence of the limitation of the exposure to radiation of the patient. As a consequence, the developments of methods for improving the CNR are valuable. The majority of existing approaches for denoising CT images are optimized for 3D (spatial) information, including spatial decimation (spatially weighted mean filters) and techniques based on wavelet and curvelet transforms. However, perfusion imaging data is 4D as it also contains temporal information. Our approach using Gaussian process regression (GPR), which takes advantage of the temporal information, to reduce the noise level. Over the entire image, GPR gains a 99% CNR improvement over the raw images and also improves the quality of haemodynamic maps allowing a better identification of edges and detailed information. At the level of individual voxel, GPR provides a stable baseline, helps us to identify key parameters from tissue time-concentration curves and reduces the oscillations in the curve. GPR is superior to the comparable techniques used in this study. (note)

  18. Prospective evaluation of stress myocardial perfusion imaging for pre-operative cardiac risk assessment

    International Nuclear Information System (INIS)

    Byrne, A.J.; Rowe, C.C.; Flannery, G.

    2002-01-01

    Full text: A prospective evaluation of patients who underwent stress myocardial perfusion imaging (MPI) to assess preoperative cardiac risk was undertaken. At the time of the scan patients were classified into 4 Clinical Risk groups (CR) based on known clinical data. On completion of the scan, the patient was then categorised into 4 Scan based Risk groups (SR), incorporating size of perfusion deficit, single versus multi-vessel disease and ejection fraction. Surgery at Austin and Repatriation Medical Centre within 6 months of scan and complications were identified using the hospital medical database. Major early cardiac events coded were death (cardiac related), myocardial infarction, unstable angina, acute pulmonary oedema, cardiac arrest, and urgent revascularisation. 208 patients have reached 6 months post-MPI scan. Of these 119 (57%) were identified as having surgery. Of the Scan Risk groups, 63% of normal, 57% of increased, and 47% of high and very high groups have had surgery. An abnormal scan is associated with a three-fold risk of cardiac complication (3.5% vs 11.3%). This is lower than most previous reports and may be due to higher representation of low risk surgical procedures (14% in this series), improved peri-operative care and/or the test result influence on management (suggested by decreasing surgical rate as SR estimate rose). Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  19. Radioaerosol ventilation imaging in ventilator-dependent patients. Technical considerations

    International Nuclear Information System (INIS)

    Vezina, W.; Chamberlain, M.; Vinitski, S.; King, M.; Nicholson, R.; Morgan, W.K.

    1985-01-01

    The differentiation of pulmonary embolism (PE) from regional ventilatory abnormalities accompanied by reduced perfusion requires contemporary perfusion and ventilation studies. Distinguishing these conditions in ventilator-dependent patients is aided by administering a Tc-99m aerosol to characterize regional ventilation, and by performing a conventional Tc-99m MAA perfusion study. The technique uses a simple in-house constructed apparatus. Simple photographic techniques suffice, but computer subtraction of perfusion from the combined perfusion-ventilation image renders interpretation easier if aerosol administration follows perfusion imaging. Multiple defects can be examined in a single study. Excluding normal or near-normal perfusion studies, PE was thought to be present in eight of 16 patients after perfusion imaging alone, but in only one of eight after added aerosol imaging. Angiography confirmed the diagnosis in that patient. Of the eight patients who had abnormal perfusion but were thought unlikely to have PE from the perfusion study alone, two had normal ventilation, and subsequently were shown to have PE by angiography. Because angiography was only performed on patients who were thought to have a high probability of PE on sequential perfusion-ventilation imaging, the true incidence of PE may have been higher. Aerosol ventilation imaging is a useful adjunct to perfusion imaging in patients on ventilators. It requires an efficient delivery system, particularly if aerosol administration follows perfusion imaging, as it does in this study

  20. Assessment of the relationship between lung parenchymal destruction and impaired pulmonary perfusion on a lobar level in patients with emphysema

    International Nuclear Information System (INIS)

    Ley-Zaporozhan, Julia; Ley, Sebastian; Eberhardt, Ralf; Weinheimer, Oliver; Fink, Christian; Puderbach, Michael; Eichinger, Monika; Herth, Felix; Kauczor, Hans-Ulrich

    2007-01-01

    Purpose: To assess the relationship between lung parenchymal destruction and impaired pulmonary perfusion on a lobar level using CT and MRI in patients with emphysema. Material and methods: Forty-five patients with severe emphysema (GOLD III and IV) underwent inspiratory 3D-HRCT and contrast-enhanced MR-perfusion (1.5T; 3.5 mm x 1.9 mm x 4 mm). 3D-HRCT data was analyzed using a software for detection and visualization of emphysema. Emphysema was categorized in four clusters with different volumes and presented as overlay on the CT. CT and lung perfusion were visually analyzed for three lobes on each side using a four-point-score to grade the abnormalities on CT (1: predominantly small emphysema-clusters to 4: >75% large emphysema-clusters) and MRI (1: normal perfusion to 4: no perfusion). Results: A total of 270 lobes were evaluated. At CT, the score was 1 for 9 lobes, 2 for 43, 3 for 77, and 4 for 141 lobes. At MRI, the score was 1 for 13 lobes, 2 for 45, 3 for 92, and 4 for 120 lobes. Matching of lung parenchymal destruction and reduced perfusion was found in 213 lobes (weighted kappa = 0.8). The score was higher on CT in 44, and higher on MRI in 13 lobes. Conclusion: 3D-HRCT and 3D MR-perfusion show a high lobar agreement between parenchymal destruction and reduction of perfusion in patients with severe emphysema

  1. Repeatability of Bolus Kinetics Ultrasound Perfusion Imaging for the Quantification of Cerebral Blood Flow

    NARCIS (Netherlands)

    Vinke, Elisabeth J.; Eyding, Jens; de Korte, Chris L.; Slump, Cornelis H.; van der Hoeven, Johannes G.; Hoedemaekers, Cornelia W.E.

    2017-01-01

    Ultrasound perfusion imaging (UPI) can be used for the quantification of cerebral perfusion. In a neuro-intensive care setting, repeated measurements are required to evaluate changes in cerebral perfusion and monitor therapy. The aim of this study was to determine the repeatability of UPI in

  2. Lung perfusion analysis with dual energy CT in patients with suspected pulmonary embolism—Influence of window settings on the diagnosis of underlying pathologies of perfusion defects

    International Nuclear Information System (INIS)

    Bauer, Ralf W.; Kerl, J. Matthias; Weber, Eva; Weisser, Philipp; Korkusuz, Huedayi; Lehnert, Thomas; Jacobi, Volkmar; Vogl, Thomas J.

    2011-01-01

    Purpose: On lung perfusion analysis with dual energy CT (DECT) in patients with suspected pulmonary embolism (PE) commonly three patterns of perfusion defects (PD) are observed: wedge-shaped, circumscribed but not wedge-shaped, and patchy. We investigated the influence of different window settings on the identification of the underlying pathologies for these types of PD. Materials and methods: 3724 segments in 196 consecutive patients who underwent pulmonary DECT angiography for clinically suspected acute PE were analyzed. Iodine distribution in the lung parenchyma was calculated from the dual energy data and displayed as color map in axial, sagittal and coronal view. Afterwards, lung and angiography window were applied separately and assessed for pulmonary embolism and pathologies of the lung parenchyma. Results: 1420 segments in 141 patients showed PD, of which 276 were wedge-shaped, 287 circumscribed and 857 patchy. Circumscribed PD were associated in 99% with interstitial or alveolar fluid collections and in 1% with located bullae. Patchy PD were associated in 65% with emphysematous or fibrotic changes, in 38% with diffuse infiltrations or interstitial fluid collections and in 0.2% with PE. The underlying pathologies for wedge-shaped PD were in 78% PE, in 3% tumors compressing pulmonary arteries, in another 3% located bullae and in further 3% infiltrations. 13% (n = 15) of the segments in this group did not show vascular or parenchymal pathologies, but in 80% (n = 10) of these cases patients had PE in another segment. Totally n = 6 of wedge-shaped PD in 5 patients remained with unclear direct cause. Conclusion: Whereas patchy and circumscribed PD are almost exclusively associated with pathologies of the lung parenchyma, wedge-shaped PD are mostly associated with PE. For a small number of wedge-shaped PD the underlying cause cannot be detected with DECT. Very small peripherally situated micro-emboli may be discussed as a reason. However, prospective trials are

  3. First-pass myocardial perfusion MR imaging with gadolinium-enhanced turbo FLASH

    International Nuclear Information System (INIS)

    Teresi, L.M.; Smith, C.; Messenger, J.; Watanabe, A.; Herbst, M.; O'Sullivan, R.M.; Lee, R.; Remer, J.; Rappaport, A.; Bradley, W.G.

    1990-01-01

    This paper determines the efficacy of MR first-pass myocardial perfusion imaging using gadolinium-enhanced Turbo--fast low-angle shot (FLASH) ultrafast imaging combined with MR systolic wall thickening data for the determination of myocardial viability. Five normal volunteers and five patients with remote myocardial infarction were studied on a 1.5-T imaging system (Siemans, Ehrlangen, NJ). Turbo-FLASH imaging utilized a 180 degrees inversion pulse followed by a rapid gradient-echo sequence (TI 400 msec, TE2 msec, TR 4.9 msec, FA 8 degrees) with a complete 64 x 64 matrix image (300 mm FOV) being acquired in 300 msec. First-pass myocardial perfusion imaging was performed in the short-axis and long-axis oblique projections with a concantenated series of Turbo-FLASH images triggered to end-systole acquired immediately before and during a rapid bolus injection of 5cc gadolinium-DTPA

  4. CT perfusion imaging in the management of posterior reversible encephalopathy

    International Nuclear Information System (INIS)

    Casey, S.O.; McKinney, A.; Teksam, M.; Liu, H.; Truwit, C.L.

    2004-01-01

    A 13-year-old girl with a renal transplant presented with hypertension and seizures. CT and MRI demonstrated typical bilateral parietal, occipital and posterior frontal cortical and subcortical edema, thought to represent posterior reversible encephalopathy syndrome. The cause was presumed to be hypertension. Antihypertensive therapy was started, lowering of the blood pressure in the range of 110-120 mmHg systolic. However, stable xenon (Xe) CT perfusion imaging revealed ischemia within the left parietal occipital region. The antihypertensive was adjusted which increased both the systolic and diastolic blood pressure by 31 mm Hg. The patient was re-imaged with Xe CT and was found to have resolution of the ischemic changes within the left parietal occipital region. In this report, we present a case in which stable Xe CT was used to monitor the degree of cerebral perfusion and guide titration of antihypertensive therapy. Such brain perfusion monitoring may have helped to prevent infarction of our patient. (orig.)

  5. Diffusion and Perfusion Magnetic Resonance Imaging:Fundamentals and Advances

    OpenAIRE

    Assili, Sanam

    2016-01-01

    Over the past few decades, magnetic resonance imaging has been utilized as a powerful imaging modality to evaluate the structure and function of various organs in the human body,such as the brain. Additionally, diffusion and perfusion MR imaging have been increasingly used in neurovascular clinical applications. In diffusion-weighted magnetic resonance imaging, the mobility of water molecules is explored in order to obtain information about the microscopic behavior of the tissues. In contrast...

  6. Pulmonary uptake of thallium-201 in patients with congenital heart disease; Comparison between total anomalous pulmonary venous connection and tetralogy of Fallot

    Energy Technology Data Exchange (ETDEWEB)

    Kohata, Tohru; Ono, Yasuo; Iwatani, Hajime; Fukushima, Hideki; Kamiya, Tetsuro; Yagihara, Toshikatsu; Nishimura, Tsunehiko; Takamiya, Makoto (National Cardiovascular Center, Suita, Osaka (Japan))

    1992-01-01

    To evaluate the pulmonary extravascular space in patients with congenital heart disease, lung uptake of Tl-201 was quantitatively studied. Patients' diseases consisted of total anomalous pulmonary venous connection (TAPVC)--supracardiac (I), paracardiac (II) and infracardiac (III) types--, tetralogy of Fallot (T/F), ventricular septal defect (VSD), and patent ductus arteriosus (PDA). Tl-201 imaging was performed before operation and in the early and late stages after operation. Twenty-five other patients with arrhythemias or a history of Kawasaki disease without perfusion defects served as controls. Lung uptake of Tl-201 was analyzed with a computer using the anterior image of the chest, and the averge count ratio of the right lung (P) to the left ventricular wall (LV) was calculated. P/LV values were compared between the patients before and after operation, and differences in anatomical types in TAPVC were also evaluated. In TAPVC, P/LV values decreased gradually after operation, but were significantly higher than those of controls even in the late stage. In the late stage after operation, type I TAPVC had significantly higher P/LV values than those of type-II. In T/F, the P/LV values were significantly higher after operation, even in the late stage, than before operation. In the VSD or PDA group, the P/LV value returned to normal after operation and was significantly lower than that before operation. In conclusion, TAPVC patients was considered to have a larger pulmonary extravascular space even in the late stage after operation, suggesting a sign of pulmonary congestion due to intrapulmonary vascular damage in utero. In T/F, scanty pulmonary vascular beds before operation were perfused with increased pulmonary blood flow after operation. Therefore, postoperative increases in pulmonary blood flow may be responsible for the increased pulmonary extravascular space. (N.K.).

  7. Automatic extraction of left ventricle in SPECT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Liu Li; Zhao Shujun; Yao Zhiming; Wang Daoyu

    1999-01-01

    An automatic method of extracting left ventricle from SPECT myocardial perfusion data was introduced. This method was based on the least square analysis of the positions of all short-axis slices pixels from the half sphere-cylinder myocardial model, and used a iterative reconstruction technique to automatically cut off the non-left ventricular tissue from the perfusion images. Thereby, this technique provided the bases for further quantitative analysis

  8. Evaluation of myocardial involvement in Duchenne's progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Kawai, Naoki; Sotobata, Iwao; Okada, Mitsuhiro

    1985-01-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. A qualitative analysis was performed from five projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in the LV posterolateral or posterior wall (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle involvements or thoracic deformities assessed by transmission computed tomography. Extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. Progression of the myocardial scintigraphic abnormalities were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies over 2 to 3 years. It was concluded that thallium myocardial perfusion imaging is a useful clinical technique to assess myocardial involvement in Duchenne's progressive muscular dystrophy. (author)

  9. Pulmonary arterial hypertension secondary to chronic thromboemboli

    International Nuclear Information System (INIS)

    Crysikopoulos, H.; Forrest, J.V.; Olson, L.K.; Roberts, A.C.

    1989-01-01

    The authors report their experience in 150 patients with pulmonary arterial hypertension secondary to chronic pulmonary embolism (CPE). Plain film findings are variable, commonly nonspecific. Occasionally nonuniformity of pulmonary perfusion or truncation of central pulmonary arteries suggest CPE. Multiple, large, unmatched perfusion defects are the most common scintigraphic observations. CT can exclude conditions mimicking CPE, particularly fibrosing mediastinitis. Pulmonary arteriography depicts the location and distribution of emboli. CPE is becoming an increasingly important entity to recognize because of available surgical treatment. Thromboendarterectomy may improve functional status and survival. The diagnosis should be considered in any patient with pulmonary arterial hypertension

  10. The clinical application of SPECT myocardial perfusion imaging with 99mTc-MIBI

    International Nuclear Information System (INIS)

    Dong Weiyu

    1992-01-01

    This paper reported 182 SPECT myocardial perfusion images with China made 99m Tc-MIBI and were compared with ECG and UCG. The sensitivity of SPECT in ischemic were 91.2% and was higher than ECG (74.9%)and UCG (61.8%) (P < 0.01). And its specificity, accuracy and positive predictive rate were 78.3%, 90% and 97% respectively. Besides 9 cases have reverse distribution after exercise and rest images. In some ICD patients had shown their SPECT images, the perfusion defects in exercise as well as in rest image

  11. The comparison of nitroglycerin interventional dual-isotope myocardium perfusion imaging and 201Tl re-injection imaging to detect viable myocardium

    International Nuclear Information System (INIS)

    Gao Zhou; Shi yu; Chen Hongyan; Jia Shaowei

    2002-01-01

    Objective: Employing the differences in physical properties of 99m Tc-MIBI and 201 Tl, the authors discuss the contrast result of nitroglycerin interventional dual-isotope myocardium perfusion imaging and 201 Tl re-injection imaging to detect viable myocardium so that authors can enhance the image quality and shorten the examination time. Method: 34 OMI patients took the 99m Tc-MIBI and 201 Tl dual-isotope myocardium perfusion imaging and 201 Tl re-injection imaging respectively in two weeks. During the peak of normal dipyridamole stress i.v. 201 Tl 100 MBq was given and myocardium imaging was taken 15 min later. The dual-isotope group was given nitroglycerin 1mg under the tongue. Five min later, i.v. 99m Tc-MIBI 1110 mBq was given. In 201 Tl re-injection group i.v. 201 Tl 40 MBq was given 4 hour later and were imaged. Among the 34 OMI patients, 19 patients undertook another 99m Tc-MIBI static imaging. Results: There are no obvious differences between nitroglycerin interventional dual-isotope myocardium perfusion imaging and 201 Tl re-injection imaging in detection rate of viable myocardium, χ 2 =0.823, p>0.25. But they have great difference in perfusion changed sectional myocardium absorb rate, t=2.73, p 2 =27.867, p 201 Tl re-injection imaging

  12. The contribution of pulmonary nuclear medicine; Imaging and physiology

    Energy Technology Data Exchange (ETDEWEB)

    Kawakami, Kenji (Jikei Univ., Tokyo (Japan). School of Medicine)

    1991-07-01

    The contribution of pulmonary nuclear medicine was evaluated in 115 patients with interstitial pulmonary diseases (IPD). Ventilation study (V) with {sup 81m}Kr or {sup 133}Xe, distribution of compliance in thoraco-pulmonary system (C) by {sup 81m}Kr gas bolus inhalation method, perfusion study (Q) with {sup 99m}Tc-MAA, {sup 67}Ga scintigraphy and an assessment of pulmonary epithelial permeability with {sup 99m}Tc-DTPA aerosol were performed as nuclear medicine procedures. Pulmonary function test (%DLco, vital capacity, and functional residual capacity) and blood gas analysis were also examined. Abnormalities in V were larger than that in Q, which was high V/Q mismatch finding, in interstitial pneumonia. Correlation between V/Q mismatch and PaO{sub 2} was, therefore, not significant. %DLco was decreased in cases with larger V/Q mismatches. {sup 67}Ga accumulated in the early stage of interstitial pneumonia when CT or chest X-ray did not show any finding. %DLco was decreased in cases with strong accumulation of {sup 67}Ga. {sup 67}Ga might be useful to evaluate activity of the disease. Pulmonary epithelial permeability was assessed by {sup 99m}Tc-DTPA inhalation study. This permeability became accelerated in idiopathic interstitial fibrosis and sarcoidosis. Pulmonary epithelial permeability may be useful as an indicator for epithelial cell injury. (author).

  13. Pulmonary vein stenosis after RF ablation diagnosed on a V/Q lung scan - a case study

    International Nuclear Information System (INIS)

    Edwards, Russell G.

    2009-01-01

    Full text: A 26-year-old female presented to the emergency department with pleuritic chest pain, acute SOB and raised D-dimer. A PE was suspected and a V/Q lung scan was performed. The initial V/Q lung scan displayed normal ventilation images but reduced perfusion throughout the left lung. Further evaluation was required and a CTPA and repeat perfusion scan were performed. After review of these imaging procedures it was discovered the patient had poor opacification of her left upper pulmonary vein compared to the left lower and right pulmonary veins. Further investigation into the patient's medical history revealed she had undergone radiofrequency ablation for atrial fibrillation 12 months prior. This was significant as it is well documented that a delayed complication of radiofrequency ablation is pulmonary vein stenosis. Although it is rare for the stenosis to be severe enough to cause symptomatic complications from this treatment for atrial fibrillation, it is becoming more widely used and therefore cases are becoming more prevalent. The patient subsequently had a stent inserted into her stenosed pulmonary vein with symptomatic relief.

  14. Spectral imaging technique for retinal perfusion detection using confocal scanning laser ophthalmoscopy

    Science.gov (United States)

    Rasta, Seyed Hossein; Manivannan, Ayyakkannu; Sharp, Peter F.

    2012-11-01

    To evaluate retinal perfusion in the human eye, a dual-wavelength confocal scanning laser ophthalmoscope (cSLO) was developed that provides spectral imaging of the fundus using a combination of red (670 nm) and near-infrared (810 nm) wavelengths. The image of the ocular fundus was analyzed to find out if quantitative measurements of the reflectivity of tissue permit assessment of the oxygen perfusion of tissue. We explored problems that affect the reproducibility of patient measurements such as non-uniformity errors on the image. For the first time, an image processing technique was designed and used to minimize the errors of oxygen saturation measurements by illumination correction in retina wide field by increasing SNR. Retinal images were taken from healthy and diabetic retinopathy eyes using the cSLO with a confocal aperture of 100 μm. The ratio image (RI) of red/IR, as oxygen saturation (SO2) index, was calculated for normal eyes. The image correction technique improved the reproducibility of the measurements. Average RI intensity variation of healthy retina tissue was determined within a range of about 5.5%. The capability of the new technique to discriminate oxygenation levels of retinal artery and vein was successfully demonstrated and showed good promise in the diagnosis of the perfused retina.

  15. Tc99m-sestamibi dosimetry in myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Toledo, Janine M.; Trindade, Bruno M.; Campos, Tarcisio P.R.

    2015-01-01

    This paper addressed myocardial perfusion imaging providing a spatial dosimetric investigation of the 99m Tc-radiopharmaceutical dose distribution at the myocardium. Radiological data manipulation was performed in order to create a computational voxel model of the heart. A set of images obtained by thoracic angiotomography and abdominal aorta was set up providing anatomic and functional information for heart modeling in SISCODES code. A homogeneous distribution of 99m Tc was assumed into the cardiac muscle. Simulations of the transport of particles through the voxel and the interaction with the heart tissues were performed on the MCNP - Monte Carlo Code. The spatial dose distribution in the heart model is displayed as well as the dose versus volume histogram of the heart muscle. The present computational tools can generate spatial doses distribution in myocardial perfusion imaging. Specially, the dosimetry performed elucidates imparted dose distribution in the myocardial muscle per unit of injected 99m Tc activity, which can contribute to future deterministic effect investigations. (author)

  16. Myocardial perfusion imaging in hyperthrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Moorin, B.

    1998-01-01

    Full text: Patients with Hyperthrophic Cardiomyopathy (HCM) frequently suffer from syncope and cardiac arrest which may lead to sudden death. This is most often caused by ventricular arrhythmia's in adults, however in young patients the mechanisms are thought to be different. Ischaemia may play a significant role even in young asymptomatic HCM patients. The mechanisms of ischaemic development in HCM differ from those in the 'normal' myocardium (Due to intramural small vessel abnormalities and abnormal myocellular architecture). In HCM the coronary microcirculation is most often affected and massive hypertrophy means more energy is required to promote contraction thus increasing oxygen demand and compounding the effects of any ischaemic changes. A case of a 12 year old HCM patient is presented who has symptoms of syncope associated with exercise whose mother died suddenly of cardiac arrest developed from HCM. A myocardial perfusion rest/stress study was undertaken to detect any underlying myocardial ischaemia. Myocardial perfusion scintigraphy demonstrates any reduction in the microcirculation in addition to that present in the macrocirculation, unlike angiography which will only detect the latter. In this case the scan clearly showed evidence of ischaemia in the lateral wall and this may be an explanation for her episodes of syncope. We suggest an algorithm or the routine work-up of young patients with HCM which makes aggressive use of myocardial perfusion imaging to detect ischaemic changes. This may identify patients who are at higher risk and will assist with treatment decisions. We feel myocardial perfusion scintigraphy is a sensitive non-invasive accurate method of detecting microcirculatory ischaemia and is thus invaluable in HCM patients

  17. [Myocardial perfusion imaging by digital subtraction angiography].

    Science.gov (United States)

    Kadowaki, H; Ishikawa, K; Ogai, T; Katori, R

    1986-03-01

    Several methods of digital subtraction angiography (DSA) were compared to determine which could better visualize regional myocardial perfusion using coronary angiography in seven patients with myocardial infarction, two with angina pectoris and five with normal coronary arteries. Satisfactory DSA was judged to be achieved if the shape of the heart on the mask film was identical to that on the live film and if both films were exactly superimposed. To obtain an identical mask film in the shape of each live film, both films were selected from the following three phases of the cardiac cycle; at the R wave of the electrocardiogram, 100 msec before the R wave, and 200 msec before the R wave. The last two were superior for obtaining mask and live films which were similar in shape, because the cardiac motion in these phases was relatively small. Using these mask and live films, DSA was performed either with the continuous image mode (CI mode) or the time interval difference mode (TID mode). The overall perfusion of contrast medium through the artery to the vein was adequately visualized using the CI mode. Passage of contrast medium through the artery, capillary and vein was visualized at each phase using TID mode. Subtracted images were displayed and photographed, and the density of the contrast medium was adequate to display contour lines as in a relief map. Using this DSA, it was found that regional perfusion of the contrast medium was not always uniform in normal subjects, depending on the typography of the coronary artery.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. The clinical application value of myocardial perfusion imaging in evaluating coronary artery myocardial bridge patients with symptoms

    International Nuclear Information System (INIS)

    Wang Yuetao; Fu Ning; Ding Xuemei; Lu Cunzhi; Zhu Feng; Wang Guanmin; Huang Yijie; Wang Linguang

    2008-01-01

    Objective: Myocardial bridge is a common inborn coronary artery anomaly, myocardial bridge may be associated with myocardial ischemia. Only a few patients with coronary artery myocardial bridge were evaluated with nuclear medicine techniques. The aim of this study was to investigate the role of nuclear cardiology with myocardial perfusion technique in symptomatic myocardial bridge patients. Methods Nineteen myocardial bridge patients with the symptoms of chest pain and chest distress were analyzed retrospectively. 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion images (both exercise and rest) were performed in all. Imaging results were compared with the results of movement electrocardiogram (ECG) and coronary arteriography. The t test or χ 2 test was used to statistically analyze the data with Stata 7.0 software. Results: Of the 19 patients, 18 patients had myocardial bridge locating at the left anterior descending artery, 1 patient at the left anterior descending and left circumflex artery, the mean angiographic systolic occlusion within the myocardial bridge was (65.4 ± 22.1)%. Of these 19 patients, Exercise-rest 99 Tc m -MIBI myocardial perfusion imaging defined positive myocardial ischemia in 10 and negative in 9 patients. Of the 10 patients with 99 Tc m -MIBI myocardial perfusion imaging defined myocardial ischemia, 8 had reversible radioactive defect of partial anterior wall and (or) apex, 1 had reversible defect of post lateral wall and post septal wall, and 1 had reversible defect of inferior wall. The positive predictive value of myocardial perfusion imaging was 52.6% (10/19), which was higher than movement ECG [21.1% (4/19), χ 2 = 4.07, P 99 Tc m -MIBI myocardial periusion imaging defined myocardial ischemia. Six cases with Grade II stenosis, two were 99 Tc m -MIBI myocardial perfusion imaging defined myocardial ischemia. Eight cases with Grade III stenosis, seven were 99 Tc m -MIBI myocardial perfusion imaging defined myocardial

  19. Brain perfusion imaging in amyotrophic lateral sclerosis with dementia

    International Nuclear Information System (INIS)

    Ishikawa, Takehisa; Morita, Mitsuya; Nakano, Imaharu

    2007-01-01

    Single photon emission computed tomography (SPECT) studies have been applied for evaluation of regional cerebral blood flow (rCBF) in various neurodegenerative disorders including amyotrophic lateral sclerosis (ALS) and ALS with dementia (ALS-D). Brain perfusion SPECT using statistical image analysis is useful for accurate and objective diagnosis to evaluate slight decreases in rCBF, even in cases difficult to assess by visual inspection. We have used statistical parametric mapping (SPM), three-dimensional stereotactic surface projection (3D-SSP), easy Z-score imaging system (eZIS) as statistical image analyses. ALS-D cases, even if a case manifests minimal mentality change, showed obvious rCBF reduction in the bilateral prefrontal area with some irregularity and laterality of its decrease. This abnormality was clear in ALS-D compared with classic ALS. Our study has demonstrated that brain perfusion SPECT imaging using statistical image analyses is quite useful as an adjunct to presume the existence of dementia in ALS, even if ALS patients have trouble in verbal or manual communication of the language because of progressive bulbar symptoms and muscle weakness. Thus, for ALS patients with any subtle signs and symptoms suggesting dementia, we recommend a SPECT study with use of statistical image analyses. (author)

  20. Studies on the clinical application of MR perfusion image using arterial spin labeling method

    International Nuclear Information System (INIS)

    Miyasaka, Kenji

    1999-01-01

    A new technique for imaging brain perfusion, arterial spin labeling method was applied in clinic. Brain perfusion was imaged by FAIR and EPISTAR both of which using arterial spin labeling (ASL) method. Suitable parameters for small contamination were examined using a imaging phantom. Then normal volunteers were examined for imaging timing. Suitable time between labeling pulse and imaging pulse for brain capillary and parenchyma was 1.0 sec. For clinical application study, total 48 patients with brain diseases were examined by FAIR and/or EPISTAR. A lesion/white matter signal intensity ratio was calculated in all clinical cases. Average of signal intensity ratio in infarction, tumor and arteriovenous malformation (AVM) were 0.8, 2.2 and 18.6 at FAIR, and 0.6, 2.2 and 12.8 at EPISTAR, respectively. Low perfusion diseases such as cerebral infarction have low signal intensity ratio and high perfusion diseases such as AVM have high signal intensity ratio in both FAIR and EPISTAR. Brain lesions were imaged similarly in FAIR and EPISTAR, and no remarkable difference was found between FAIR and EPISTAR. As a result of diagnostic trial by signal intensity ratio in operated tumor, hemorrhagic cases could be diagnosed by accuracies of 75% in FAIR and 100% in EPISTAR, respectively. (author)

  1. Adenosine stress and exercise 99Tcm-MIBI myocardial perfusion imaging in the diagnosis and risk stratification of patients with unstable angina

    International Nuclear Information System (INIS)

    Jia Peng; Guo Wanhua; Xu Shoulin; Feng Xuefeng

    2008-01-01

    Objective: The aim of this study was to evaluate the clinical value of adenosine stress or exercise 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion imaging in the diagnosis and risk stratification of patients with unstable angina. Methods: Eighty-seven hospitalized patients with unstable angina [54 men and 33 women, aged of (56.5±12.5) years] underwent adenosine stress or exercise myocardial perfusion imaging and coronary angiography. Patients were followed up. Results: Fifty-seven patients had abnormal myocardial perfusion imaging and significant coronary artery stenosis. Ten patients had abnormal myocardial perfusion imaging but normal coronary angiography. Eight patients had normal myocardial perfusion imaging but significant coronary artery stenosis. Twelve patients had normal myocardial perfusion imaging and normal coronary angiography. Patients with abnormal myocardial perfusion imaging had worse prognosis. There was relationship between cardiac events and the extent and severity of myocardial ischemia. Conclusion: Adenosine stress and exercise myocardial perfusion imaging is of important clinical value in the diagnosis and risk stratification of patients with unstable angina. (authors)

  2. Study of pathophysiology of pulmonary circulation in polycythemia using scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Tadashige; Tanaka, Masao; Takeda, Tadashi; Kawashima, Akira; Kubo, Keiji; Kobayashi, Toshio; Handa, Kenjiro; Yoshimura, Kazuhiko (Shinshu Univ., Matsumoto, Nagano (Japan). Faculty of Medicine)

    1993-09-01

    In order to evaluate the pathophysiology of pulmonary circulation in polycythemia, Tl-201 myocardial scintigraphy and perfusion lung scintigraphy with 99m-Tc-MAA were performed in 19 cases of polycythemia including polycythemia rubra vera and in 11 cases of secondary polycythemia due to pulmonary diseases. Tl-201 lung uptake, right ventricular visualization and pulmonary perfusion impairment were studied. In the 19 cases, Tl-201 lung uptake was observed in all cases and 54.5% of them showed moderate lung uptake. The grade of right ventricular visualization was moderate in one case and slight in 16 cases; right ventricular hypertrophy was shown in 89.5% of all cases by Tl-201 scintigraphy, only one of which showed right ventricular hypertrophy on electrocardiography. Abnormalities of lung perfusion consisted of scattered small areas of hypoperfusion in 36.8%, peripheral hypoperfusion in 78.9% and uneven distribution of pulmonary perfusion in 94.7%. The degree of hypoperfusion was slightly related to decrease in FEV 1.0%, V25 and PaO[sub 2] and increase in circulating blood volume and peripheral red blood cell counts. Abnormalities of pulmonary function consisted of increased RV/TLC in 50.0%, increased CV/VC in 35.7% and decreased V25 in 36.8%. Arterial blood gases showed hypoxemia in 57.1%, the degree of which was slightly related to increase in RV/TLC and CV/VC and decrease in V25. Cases of secondary polycythemia due to pulmonary diseases showed more marked right ventricular visualization, pulmonary perfusion impairment and abnormalities of various kinds of pulmonary function than polycythemia rubra vera cases. It seems to be important to evaluate the pathophysiology of pulmonary circulation in polycythemia rubra vera as well as secondary polycythemia due to cardio-pulmonary diseases, because pulmonary perfusion impairment and moderate right ventricular visualization are observed frequently in polycythemia rubra vera. (author).

  3. Study of pathophysiology of pulmonary circulation in polycythemia using scintigraphy

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Takeda, Tadashi; Kawashima, Akira; Kubo, Keiji; Kobayashi, Toshio; Handa, Kenjiro; Yoshimura, Kazuhiko

    1993-01-01

    In order to evaluate the pathophysiology of pulmonary circulation in polycythemia, Tl-201 myocardial scintigraphy and perfusion lung scintigraphy with 99m-Tc-MAA were performed in 19 cases of polycythemia including polycythemia rubra vera and in 11 cases of secondary polycythemia due to pulmonary diseases. Tl-201 lung uptake, right ventricular visualization and pulmonary perfusion impairment were studied. In the 19 cases, Tl-201 lung uptake was observed in all cases and 54.5% of them showed moderate lung uptake. The grade of right ventricular visualization was moderate in one case and slight in 16 cases; right ventricular hypertrophy was shown in 89.5% of all cases by Tl-201 scintigraphy, only one of which showed right ventricular hypertrophy on electrocardiography. Abnormalities of lung perfusion consisted of scattered small areas of hypoperfusion in 36.8%, peripheral hypoperfusion in 78.9% and uneven distribution of pulmonary perfusion in 94.7%. The degree of hypoperfusion was slightly related to decrease in FEV 1.0%, V25 and PaO 2 and increase in circulating blood volume and peripheral red blood cell counts. Abnormalities of pulmonary function consisted of increased RV/TLC in 50.0%, increased CV/VC in 35.7% and decreased V25 in 36.8%. Arterial blood gases showed hypoxemia in 57.1%, the degree of which was slightly related to increase in RV/TLC and CV/VC and decrease in V25. Cases of secondary polycythemia due to pulmonary diseases showed more marked right ventricular visualization, pulmonary perfusion impairment and abnormalities of various kinds of pulmonary function than polycythemia rubra vera cases. It seems to be important to evaluate the pathophysiology of pulmonary circulation in polycythemia rubra vera as well as secondary polycythemia due to cardio-pulmonary diseases, because pulmonary perfusion impairment and moderate right ventricular visualization are observed frequently in polycythemia rubra vera. (author)

  4. Value of high spatial and high temporal resolution magnetic resonance angiography for differentiation between idiopathic and thromboembolic pulmonary hypertension: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Ley, Sebastian; Eichinger, Monika [DKFZ, Department of Radiology (E010), Heidelberg (Germany); Johannes Gutenberg-University, Department of Radiology, University Hospital Mainz, Mainz (Germany); Fink, Christian; Zaporozhan, Julia; Puderbach, Michael; Plathow, Christian; Kauczor, Hans-Ulrich [DKFZ, Department of Radiology (E010), Heidelberg (Germany); Borst, Mathias M.; Meyer, F. Joachim; Gruenig, Ekkehard [University Heidelberg, Department of Internal Medicine, Heidelberg (Germany); Kreitner, Karl-Friedrich [Johannes Gutenberg-University, Department of Radiology, University Hospital Mainz, Mainz (Germany)

    2005-11-01

    Differentiation between different forms of pulmonary hypertension (PH) is essential for correct disease management. The goal of this study was to elucidate the clinical impact of high spatial resolution MR angiography (SR-MRA) and time-resolved MRA (TR-MRA) to differentiate between patients with chronic thromboembolic PH (CTEPH) and idiopathic pulmonary arterial hypertension (IPAH). Ten PH patients and five volunteers were examined. Twenty TR-MRA data sets (TA 1.5 s) and SR-MRA (TA 23 s) were acquired. TR-MRA data sets were subtracted as angiography and perfusion images. Evaluation comprised analysis of vascular pathologies on a segmental basis, detection of perfusion defects, and bronchial arteries by two readers in consensus. Technical evaluation comprised evaluation of image quality, signal-to-noise ratio (SNR) measurements, and contrast-media passage time. Visualization of the pulmonary arteries was possible down to a subsegmental (SR-MRA) and to a segmental (TR-MRA) level. SR-MRA outperformed TR-MRA in direct visualization of intravascular changes. Patients with IPAH predominantly showed tortuous pulmonary arteries while in CTEPH wall irregularities and abnormal proximal-to-distal tapering was found. Perfusion images showed a diffuse pattern in IPAH and focal defects in CTEPH. TR-MRA and SR-MRA resulted in the same final diagnosis. Both MRA techniques allowed for differentiation between IPAH and CTEPH. Therefore, TR-MRA can be used in the clinical setting, especially in dyspneic patients. (orig.)

  5. Visualization of pulmonary nodules with magnetic resonance imaging (MRI)

    International Nuclear Information System (INIS)

    Plathow, C.; Deutsches Krebsforschungszentrum; Meinzer, H.-P.; Kauczor, H.-U.

    2006-01-01

    Visualization of pulmonary nodules using magnetic resonance imaging (MRI) plays a minor role compared with computed tomography (CT). Technical developments made it possible to apply MRI more and more frequently in functional imaging. Imaging of the motion of pulmonary nodules during respiration, e.g., to optimize high precision therapy techniques, is a new field of research. This paper describes developments in analysis and visualization of pulmonary nodules during respiration using MRI. Besides actual 2D techniques new 3D techniques to quantify motion of pulmonary nodules during respiration are presented. (orig.) [de

  6. Functional and perfusion magnetic resonance imaging at 3 tesla

    International Nuclear Information System (INIS)

    Klarhoefer, M.

    2001-03-01

    This thesis deals with the development and optimization of fast magnetic resonance imaging (MRI) methods for non-invasive functional studies of the human brain and perfusion imaging on a 3 Tesla (T) whole body NMR system. The functional MRI (fMRI) experiments performed showed that single-shot multi-echo EPI and spiral imaging techniques provide fast tools to obtain information about T2* distributions during functional activation in the human brain. Both sequences were found to be useful in the separation of different sources contributing to the functional MR signal like inflow or susceptibility effects in the various vascular environments. An fMRI study dealing with the involvement of prefrontal brain regions in movement preparation lead to inconsistent results. It could not be clarified if these were caused by problems during a spatial normalization process of the individual brains or if the functional paradigm, using very short inter-stimulus intervals, was not suited for the problem investigated. Blood flow velocity measurements in the human finger showed that the use of a strong, small-bore gradient system permits short echo times that reduce flow artefacts and allows high spatial resolution in order to keep systematic errors due to partial volume effects small. With regard to the perfusion investigations an inversion recovery snapshot-FLASH sequence was implemented, which allowed the acquisition of T1 parameter maps of the human brain within a few seconds. The accuracy of this method was demonstrated in test objects. The perfusion investigations with FAIR showed good qualitative results, whereas the quantitative analysis did not yield reproducible findings. A reason for the poor results could be the low signal-to-noise ratio (SNR) of the FAIR images or an incomplete global inversion of the magnetization due to the transmission characteristics of the radio-frequency coil. The BASE sequence that did not require a global inversion yielded quantitative perfusion

  7. Renal perfusion scintiscan

    Science.gov (United States)

    ... Radionuclide renal perfusion scan; Perfusion scintiscan - renal; Scintiscan - renal perfusion Images Kidney anatomy Kidney - blood and urine flow Intravenous pyelogram References Rottenberg G, Andi AC. Renal ...

  8. Prediction of Liver Function by Using Magnetic Resonance-based Portal Venous Perfusion Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cao Yue, E-mail: yuecao@umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Wang Hesheng [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Johnson, Timothy D. [Department of Biostatistics, University of Michigan, Ann Arbor, Michigan (United States); Pan, Charlie [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Hussain, Hero [Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Balter, James M.; Normolle, Daniel; Ben-Josef, Edgar; Ten Haken, Randall K.; Lawrence, Theodore S.; Feng, Mary [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States)

    2013-01-01

    Purpose: To evaluate whether liver function can be assessed globally and spatially by using volumetric dynamic contrast-enhanced magnetic resonance imaging MRI (DCE-MRI) to potentially aid in adaptive treatment planning. Methods and Materials: Seventeen patients with intrahepatic cancer undergoing focal radiation therapy (RT) were enrolled in institution review board-approved prospective studies to obtain DCE-MRI (to measure regional perfusion) and indocyanine green (ICG) clearance rates (to measure overall liver function) prior to, during, and at 1 and 2 months after treatment. The volumetric distribution of portal venous perfusion in the whole liver was estimated for each scan. We assessed the correlation between mean portal venous perfusion in the nontumor volume of the liver and overall liver function measured by ICG before, during, and after RT. The dose response for regional portal venous perfusion to RT was determined using a linear mixed effects model. Results: There was a significant correlation between the ICG clearance rate and mean portal venous perfusion in the functioning liver parenchyma, suggesting that portal venous perfusion could be used as a surrogate for function. Reduction in regional venous perfusion 1 month after RT was predicted by the locally accumulated biologically corrected dose at the end of RT (P<.0007). Regional portal venous perfusion measured during RT was a significant predictor for regional venous perfusion assessed 1 month after RT (P<.00001). Global hypovenous perfusion pre-RT was observed in 4 patients (3 patients with hepatocellular carcinoma and cirrhosis), 3 of whom had recovered from hypoperfusion, except in the highest dose regions, post-RT. In addition, 3 patients who had normal perfusion pre-RT had marked hypervenous perfusion or reperfusion in low-dose regions post-RT. Conclusions: This study suggests that MR-based volumetric hepatic perfusion imaging may be a biomarker for spatial distribution of liver function, which

  9. Near fatal pulmonary embolism in a 16-year-old

    International Nuclear Information System (INIS)

    Farlow, D.; Field, L.

    1992-01-01

    Acute pulmonary thrombo-embolism (PE) may present with a variety of clinical problems; patients with this condition may range from being asymptomatic to acutely unwell, with sudden death being at the extreme end of the spectrum. This case report of a young man with PE demonstrates the scintigraphic features of massive, near-fatal embolism. On transfer to the Nuclear Medicine Department, the patient's blood pressure was unrecordable, the heart rate was 150/min, there was deep cyanosis despite 100 per cent oxygen and the pupils were fixed and dilated. A limited perfusion scan was obtained using 76 MBq of 99m Tc-MAA (Technescan MAA, Mallinckrodt), with an estimated 260 000 MAA particles being injected directly into a peripheral vein. Anterior and posterior images showed perfusion only to a small portion of the left upper lobe. The patient recovered quickly following embolectomy resulting in removal of a large amount of thrombus from both pulmonary arteries. It has been thus demonstrated that the perfusion scan is a rapid and safe method of confirming suspected massive PE prior to surgery. 4 refs., 2 figs

  10. Imaging diagnosis of acute pulmonary thromboembolism

    International Nuclear Information System (INIS)

    Mut, Fernando

    2005-01-01

    Pulmonary embolism (PE) is a frequent disease which requires an accurate diagnosis in order to establish an effective treatment considering that anticoagulant therapy may lead to complications. Lung ventilation / perfusion scintigraphy (LS V/Q) has been employed as the imaging meted of choice in patients with suspicion of PE. Pulmonary angiography is considered invasive, hence its utilization is usually reserved for otherwise unresolved cases. Other methods like venous Doppler ultrasound and echocardiography have a complementary role or are not widely indicated. The introduction of spiral CT (SCT), specially with multislice capabilities has made available a fast, relatively economic and efficient method for non-invasive diagnosis of PE. Availability of the technique is increasing and it has been included in some diagnostic algorithms for PE as the initial method of evaluation (and sometimes the only one). However, most research has been performed comparing this state-of-the-art technology with classical radionuclide protocols instead of using updated techniques such as SPECT and ultrafine radio aerosols. Moreover, SCT delivers much higher dose rates to the patient which must be taken into account specially in young individuals. In general, available evidence shows superior sensitivity of LS V/Q with higher specificity of SCT, within a context of similar overall accuracy provided optimized protocols are employed. Interpretation criteria for LS V/Q should be revised in an attempt to minimize indeterminate results, and together with the routine utilization of SPECT and novel ventilation systems should improve the performance of LS V/Q. The choice of the initial diagnostic modality should be guided by a correct determination of pre-test probability, clinical characteristics of the patient potentially influencing the efficacy and safety of the method, availability of the different techniques, relative costs and operator's experience. Such a selective and pragmatic

  11. Preoperative localization of epileptic foci with SPECT brain perfusion imaging, electrocorticography, surgery and pathology

    International Nuclear Information System (INIS)

    Jia Shaowei; Xu Wengui; Chen Hongyan; Weng Yongmei; Yang Pinghua

    2002-01-01

    Objective: The value of preoperative localization of epileptic foci with SPECT brain perfusion imaging was investigated. Methods: The study population consisted of 23 patients with intractable partial seizures which was difficult to control with anticonvulsant for long period. In order to preoperatively locate the epileptic foci, double SPECT brain perfusion imaging was performed during interictal and ictal stage. The foci were confirmed with electrocorticography (EcoG), surgery and pathology. Results: The author checked with EcoG the foci shown by SPECT, 23 patients had all typical spike discharge. The regions of radioactivity increase in ictal matched with the abnormal electrical activity areas that EcoG showed. The spike wave originated in the corresponding cerebrum cortex instead of hyperplastic and adherent arachnoid or tumor itself. Conclusions: SPECT brain perfusion imaging contributes to distinguishing location, size, perfusion and functioning of epileptogenic foci, and has some directive function on to making out a treatment programme at preoperation

  12. Hepatic perfusion disorders: a pictorial review of CT and MR imaging

    International Nuclear Information System (INIS)

    Yim, Nam Yeol; Jeong, Yong Yeon; Shin, Sang Soo; Song, Sang Gook; Lim, Hyo Soon; Heo, Suk Hee; Chang, Nam Kyu; Yoon, Woong; Kang, Heoung Keun; Lan, Shen Yu

    2005-01-01

    The liver has a unique dual blood supply through the portal vein and the hepatic artery. There are several communications between these two vessels under various conditions such as in hepatic tumors, trauma and liver cirrhosis, vascular compromise, among others. When vascular compromise occurs, this dual blood supply system can cause changes in the volume of blood flow in individual vessels or even in the direction of blood flow. With rapid image acquisition and increased resolution available in multislice CT and MR imaging, hepatic perfusion disorders are now more frequently encountered than in the past. Familiarity with imaging findings of these perfusion disorders will be helpful in characterizing focal hepatic lesions and will also help to avoid false positive diagnoses

  13. Hepatic perfusion disorders: a pictorial review of CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yim, Nam Yeol; Jeong, Yong Yeon; Shin, Sang Soo; Song, Sang Gook; Lim, Hyo Soon; Heo, Suk Hee; Chang, Nam Kyu; Yoon, Woong; Kang, Heoung Keun [Chonnam National University, Gwangju (Korea, Republic of); Lan, Shen Yu [Yan Bian Cancer Hospital, Peijing (China)

    2005-09-15

    The liver has a unique dual blood supply through the portal vein and the hepatic artery. There are several communications between these two vessels under various conditions such as in hepatic tumors, trauma and liver cirrhosis, vascular compromise, among others. When vascular compromise occurs, this dual blood supply system can cause changes in the volume of blood flow in individual vessels or even in the direction of blood flow. With rapid image acquisition and increased resolution available in multislice CT and MR imaging, hepatic perfusion disorders are now more frequently encountered than in the past. Familiarity with imaging findings of these perfusion disorders will be helpful in characterizing focal hepatic lesions and will also help to avoid false positive diagnoses.

  14. Clinical applications of brain perfusion imaging with 99mTc-HM-PAO

    International Nuclear Information System (INIS)

    Lin Xiangtong

    1989-01-01

    200 patients with central nervous system diseases were studied with 99m Tc-HM-PAO and SPECT, including Parkinson's disease (PD) 47, Vascular headache 69, CVD 34, Epilepsy 26, Head truma 10, Brain tumor 5 and other 9 cases. Part of them have been compared with the results of MRI, X-CT and EEG. The positivity of SPECT in PD is 61.7% with decrease perfusion in local area of cerebram and basal ganglia and only 4 cases had lower perfusion in cerebellum; in headache is 46.4%, showing variable perfusion patterns; in CVD is 79.4% with decrease perfusion, luxury perfusion and the phenomenon of 'diaschsis'. In epilepsy, the abnormal foci mostly localize in temporal lobe and have close relation to the results of EEG. In brain tumor it also denotes decreased uptake of tracer. The clinicl singnificance of brain perfusion imaging with 99m Tc-HM-PAO was discussed

  15. Quantitative myocardial perfusion PET parametric imaging at the voxel-level

    International Nuclear Information System (INIS)

    Mohy-ud-Din, Hassan; Rahmim, Arman; Lodge, Martin A

    2015-01-01

    Quantitative myocardial perfusion (MP) PET has the potential to enhance detection of early stages of atherosclerosis or microvascular dysfunction, characterization of flow-limiting effects of coronary artery disease (CAD), and identification of balanced reduction of flow due to multivessel stenosis. We aim to enable quantitative MP-PET at the individual voxel level, which has the potential to allow enhanced visualization and quantification of myocardial blood flow (MBF) and flow reserve (MFR) as computed from uptake parametric images. This framework is especially challenging for the 82 Rb radiotracer. The short half-life enables fast serial imaging and high patient throughput; yet, the acquired dynamic PET images suffer from high noise-levels introducing large variability in uptake parametric images and, therefore, in the estimates of MBF and MFR. Robust estimation requires substantial post-smoothing of noisy data, degrading valuable functional information of physiological and pathological importance. We present a feasible and robust approach to generate parametric images at the voxel-level that substantially reduces noise without significant loss of spatial resolution. The proposed methodology, denoted physiological clustering, makes use of the functional similarity of voxels to penalize deviation of voxel kinetics from physiological partners. The results were validated using extensive simulations (with transmural and non-transmural perfusion defects) and clinical studies. Compared to post-smoothing, physiological clustering depicted enhanced quantitative noise versus bias performance as well as superior recovery of perfusion defects (as quantified by CNR) with minimal increase in bias. Overall, parametric images obtained from the proposed methodology were robust in the presence of high-noise levels as manifested in the voxel time-activity-curves. (paper)

  16. Diagnosis of Alzheimer's disease using brain perfusion SPECT and MR imaging: which modality achieves better diagnostic accuracy?

    International Nuclear Information System (INIS)

    Kubota, Takao; Ushijima, Yo; Yamada, Kei; Okuyama, Chio; Kizu, Osamu; Nishimura, Tsunehiko

    2005-01-01

    The purpose of this study was to compare the accuracy of MR imaging and brain perfusion single-photon emission tomography (SPECT) in diagnosing Alzheimer's disease (AD). The transaxial section display of brain perfusion SPECT, three-dimensional stereotactic surface projection (3D-SSP) SPECT image sets, thin-section MR imaging of the hippocampus and perfusion MR imaging were evaluated in 66 subjects comprising 35 AD patients and 31 subjects without AD. SPECT and MR imaging were visually interpreted by two experts and two novices, and the diagnostic ability of each modality was evaluated by receiver operating characteristic (ROC) analysis. In the experts' interpretations, there was no significant difference in the area under the ROC curve (A z ) between 3D-SSP and thin-section MR imaging, whereas the A z of transaxial SPECT display was significantly lower than that of 3D-SSP (3D-SSP: 0.97, thin-section MR imaging: 0.96, transaxial SPECT: 0.91), and the A z of perfusion MR imaging was lowest (0.63). The sensitivity and specificity of each modality were, respectively, 80.0% and 96.8% for 3D-SSP, 77.1% and 96.8% for thin-section MR imaging, 60.0% and 93.5% for transaxial SPECT display and 34.3% and 100% for perfusion MR imaging. In the novices' interpretations, the A z , sensitivity and specificity of 3D-SSP were superior to those of thin-section MR imaging. Thin-section hippocampal MR imaging and 3D-SSP image sets had potentially equivalent value for the diagnosis of AD, and they were superior to transaxial SPECT display and perfusion MR imaging. For avoidance of the effect of interpreters' experience on image evaluation, 3D-SSP appears to be optimal. (orig.)

  17. Myocardial perfusion imaging for detection of silent myocardial ischemia

    International Nuclear Information System (INIS)

    Beller, G.A.

    1988-01-01

    Despite the widespread use of the exercise stress test in diagnosing asymptomatic myocardial ischemia, exercise radionuclide imaging remains useful for detecting silent ischemia in numerous patient populations, including those who are totally asymptomatic, those who have chronic stable angina, those who have recovered from an episode of unstable angina or an uncomplicated myocardial infarction, and those who have undergone angioplasty or received thrombolytic therapy. Studies show that thallium scintigraphy is more sensitive than exercise electrocardiography in detecting ischemia, i.e., in part, because perfusion defects occur more frequently than ST depression and before angina in the ischemic cascade. Thallium-201 scintigraphy can be performed to differentiate a true- from a false-positive exercise electrocardiographic test in patients with exercise-induced ST depression and no angina. The development of technetium-labeled isonitriles may improve the accuracy of myocardial perfusion imaging. 11 references

  18. An attempt of thallium-201 myocardial perfusion imaging during transient coronary arterial occlusion by PTCA

    International Nuclear Information System (INIS)

    Nakagawa, Tatsuya; Sugihara, Hiroki; Katahira, Toshio

    1989-01-01

    To evaluate the myocardial perfusion during transient coronary occlusion, we attempted to obtain the myocardial scintigraphy during percutaneous transluminal coronary angioplasty (PTCA). Tl-201 was injected at the last inflation of angioplastic balloon and occlusion was kept on for 60 sec. Planar images or SPECT were obtained immediately after PTCA. With this protocol, myocardial perfusion defects were observed during PTCA and fully redistributed 3 hours after Tl injection. Extent of ischemic lesions were almost same as that observed during exercise in two cases without collateral vessels. In a case with well visualized collateral vessels, perfusion defect was smaller in PTCA images than that in exercise stressed images. We conclude that intravenous injection of Tl-201 during PTCA is useful to assess the alteration of myocardial perfusion due to transient coronary occlusion without increasing the risk of angioplastic procedure. (author)

  19. Functional Imaging: CT and MRI

    OpenAIRE

    van Beek, Edwin JR; Hoffman, Eric A

    2008-01-01

    Numerous imaging techniques permit evaluation of regional pulmonary function. Contrast-enhanced CT methods now allow assessment of vasculature and lung perfusion. Techniques using spirometric controlled MDCT allow for quantification of presence and distribution of parenchymal and airway pathology, Xenon gas can be employed to assess regional ventilation of the lungs and rapid bolus injections of iodinated contrast agent can provide quantitative measure of regional parenchymal perfusion. Advan...

  20. Mucous plug syndrome. A pulmonary embolism mimic

    International Nuclear Information System (INIS)

    Bray, S.T.; Johnstone, W.H.; Dee, P.M.; Pope, T.L. Jr.; Teates, C.D.; Tegtmeyer, C.J.

    1984-01-01

    Reported are ten instances of major bronchial obstruction by mucous plugs in eight patients during which the clinical features resembled pulmonary embolism. Perfusion lung studies showed significantly diminished perfusion of the involved portions of the lungs. The chest radiographs generally did not, however, reflect the severity of the airway obstruction and in some instances were completely normal. The ventilation studies indicated the extent and severity of the obstruction and matched with the perfusion scans. Pulmonary arteriograms were performed in three patients and gave direct evidence of focally diminished lung perfusion without embolism. The physiologic mechanisms underlying the condition are discussed

  1. Update on diagnostic strategies of pulmonary embolism

    International Nuclear Information System (INIS)

    Kauczor, H.U.; Heussel, C.P.; Thelen, M.

    1999-01-01

    Acute pulmonary embolism is a frequent disease with non-specific findings, high mortality, and multiple therapeutic options. A definitive diagnosis must be established by accurate, non-invasive, easily performed, cost-effective, and widely available imaging modalities. Conventional diagnostic strategies have relied on ventilation-perfusion scintigraphy complemented by venous imaging. If the results are inconclusive, pulmonary angiography, which is regarded as the gold standard, is to be performed. Recently, marked improvements in CT and MRI and shortcomings of scintigraphy led to an update of the diagnostic strategy. Spiral CT is successfully employed as a second-line procedure to clarify indeterminate scintigraphic results avoiding pulmonary angiography. It can also be used as a first-line screening tool if service and expertise is provided. Venous imaging is indicated if CT is inconclusive. The MRI technique can be applied as an alternative second-line test if spiral CT is not available or is contraindicated. It has the greatest potential for further developments and refinements. Echocardiography should be used as a first-line bedside examination in critical patients. If inconclusive stabilized patients undergo spiral CT, unstable patients should be referred for pulmonary angiography. Chronic thromboembolic pulmonary hypertension is a rare sequela of acute pulmonary embolism which can be cured surgically. Morphology, complications, and differential diagnoses are better illustrated by spiral CT and MRA, whereas invasive acquisition of hemodynamic data is the sole advantage of angiography. (orig.)

  2. An evaluation of the feasibility of assessment of volume perfusion for the whole lung by 128-slice spiral CT

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Haitao [Imaging Center of Taian Central Hospital, Taian, Shandong (China); Gao, Fei; Li, Ning; Liu, Cheng [Shandong Univ., Shandong Medical Imaging Research Inst., CT Room, Shandong (China)], e-mail: liucheng491025@sina.com

    2013-10-15

    Background: Lung perfusion based on dynamic scanning cannot provide a quantitative assessment of the whole lung because of the limited coverage of the current computed tomography (CT) detector designs. Purpose: To evaluate the feasibility of dynamic volume perfusion CT (VPCT) of the whole lung using a 128-slice CT for the quantitative assessment and visualization of pulmonary perfusion. Material and Methods: Imaging was performed in a control group of 17 subjects who had no signs of disturbance of pulmonary function or diffuse lung disease, and 15 patients (five patients with acute pulmonary embolism and 10 with emphysema) who constituted the abnormal lung group. Dynamic VPCT was performed in all subjects, and pulmonary blood flow (PBF), pulmonary blood volume (PBV), and mean transit time (MTT) were calculated from dynamic contrast images with a coverage of 20.7 cm. Regional and volumetric PBF, PBV, and MTT were statistically evaluated and comparisons were made between the normal and abnormal lung groups. Results: Regional PBF (94.2{+-}36.5, 161.8 {+-}29.6, 185.7 {+-}38.1 and 125.5 {+-}46.1, 161.9 {+-}31.4, 169.3 {+-}51.7), PBV (6.7 {+-}2.8, 10.9 {+-}3.0, 12.9 {+-}4.5 and 9.9 {+-}4.6, 10.3 {+-}2.9, 11.9 {+-}4.5), and MTT (5.8 {+-}2.4, 4.5 {+-}1.3, 4.7 {+-}2.1 and 5.6 {+-}2.3, 4.3 {+-}1.5, 4.9 {+-}1.5) demonstrated significant differences in the gravitational and isogravitational directions in the normal lung group (P < 0.05). The PBF (154.2 {+-}30.6 vs. 94.9 {+-}15.9) and PBV (11.1 {+-}4.0 vs. 6.6 {+-}1.7) by dynamic VPCT showed significant differences between normal and abnormal lungs (P < 0.05), notwithstanding the four large lungs that had coverage > 20.7 cm. Conclusion: Dynamic VPCT of the whole lung is feasible for the quantitative assessment of pulmonary perfusion by 128-slice CT, and may in future permit the evaluation of both morphological and functional features of the whole lung in a single examination.

  3. Contrast-enhanced 3D MRI of lung perfusion in children with cystic fibrosis - initial results

    International Nuclear Information System (INIS)

    Eichinger, Monika; Puderbach, Michael; Zuna, Ivan; Kauczor, Hans-Ulrich; Fink, Christian; Gahr, Julie; Mueller, Frank-Michael; Ley, Sebastian; Plathow, Christian; Tuengerthal, Siegfried

    2006-01-01

    This paper is a feasibility study of magnetic resonance imaging (MRI) of lung perfusion in children with cystic fibrosis (CF) using contrast-enhanced 3D MRI. Correlation assessment of perfusion changes with structural abnormalities. Eleven CF patients (9 f, 2 m; median age 16 years) were examined at 1.5 T. Morphology: HASTE coronal, transversal (TR/TE/α/ST: 600 ms/28 ms/180 /6 mm), breath-hold 18 s. Perfusion: Time-resolved 3D GRE pulse sequence (FLASH, TE/TR/α: 0.8/1.9 ms/40 ), parallel imaging (GRAPPA, PAT 2). Twenty-five data sets were acquired after intravenous injection of 0.1 mmol/kg body weight of gadodiamide, 3-5 ml/s. A total of 198 lung segments were analyzed by two radiologists in consensus and scored for morphological and perfusion changes. Statistical analysis was performed by Mantel-Haenszel chi-square test. Results showed that perfusion defects were observed in all patients and present in 80% of upper, and 39% of lower lobes. Normal lung parenchyma showed homogeneous perfusion (86%, P<0.0001). Severe morphological changes led to perfusion defects (97%, P<0.0001). Segments with moderate morphological changes showed normal (53%) or impaired perfusion (47%). In conclusion, pulmonary perfusion is easy to judge in segments with normal parenchyma or severe changes. In moderately damaged segments, MRI of lung perfusion may help to better assess actual functional impairment. Contrast-enhanced 3D MRI of lung perfusion has the potential for early vascular functional assessment and therapy control in CF patients. (orig.)

  4. Time-resolved computed tomography of the liver: retrospective, multi-phase image reconstruction derived from volumetric perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Michael A.; Kartalis, Nikolaos; Aspelin, Peter; Albiin, Nils; Brismar, Torkel B. [Karolinska University Hospital, Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Stockholm (Sweden); Leidner, Bertil; Svensson, Anders [Karolinska University Hospital, Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Stockholm (Sweden); Karolinska University Hospital Huddinge, Department of Radiology, Stockholm (Sweden)

    2014-01-15

    To assess feasibility and image quality (IQ) of a new post-processing algorithm for retrospective extraction of an optimised multi-phase CT (time-resolved CT) of the liver from volumetric perfusion imaging. Sixteen patients underwent clinically indicated perfusion CT using 4D spiral mode of dual-source 128-slice CT. Three image sets were reconstructed: motion-corrected and noise-reduced (MCNR) images derived from 4D raw data; maximum and average intensity projections (time MIP/AVG) of the arterial/portal/portal-venous phases and all phases (total MIP/ AVG) derived from retrospective fusion of dedicated MCNR split series. Two readers assessed the IQ, detection rate and evaluation time; one reader assessed image noise and lesion-to-liver contrast. Time-resolved CT was feasible in all patients. Each post-processing step yielded a significant reduction of image noise and evaluation time, maintaining lesion-to-liver contrast. Time MIPs/AVGs showed the highest overall IQ without relevant motion artefacts and best depiction of arterial and portal/portal-venous phases respectively. Time MIPs demonstrated a significantly higher detection rate for arterialised liver lesions than total MIPs/AVGs and the raw data series. Time-resolved CT allows data from volumetric perfusion imaging to be condensed into an optimised multi-phase liver CT, yielding a superior IQ and higher detection rate for arterialised liver lesions than the raw data series. (orig.)

  5. Evaluation of myocardial involvement in Duchenne progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Kawai, Naoki; Yamamoto, Shuhei; Okada, Mitsuhiro

    1983-01-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. The qualitative analysis was performed in anterior, 3 left anterior oblique and left lateral projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in LV posterolateral or posterior walls (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle changes or thoracic deformities assessed by transmission computed tomography. Slightly increased thallium-201 activity in RV free wall and lungs was shown in nine and one patient, respectively. The extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. The myocardial scintigraphic changes were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies in 2 to 3 years. It was concluded that the thallium myocardial perfusion imaging was a useful clinical technique to evaluate the cardiomyopathy in Duchenne progressive muscular dystrophy. (author)

  6. Evaluation of myocardial involvement in Duchenne progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, Naoki; Yamamoto, Shuhei; Okada, Mitsuhiro (Nagoya Univ. (Japan). Faculty of Medicine)

    1983-12-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. The qualitative analysis was performed in anterior, 3 left anterior oblique and left lateral projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in LV posterolateral or posterior walls (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle changes or thoracic deformities assessed by transmission computed tomography. Slightly increased thallium-201 activity in RV free wall and lungs was shown in nine and one patient, respectively. The extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. The myocardial scintigraphic changes were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies in 2 to 3 years. It was concluded that the thallium myocardial perfusion imaging was a useful clinical technique to evaluate the cardiomyopathy in Duchenne progressive muscular dystrophy.

  7. Perfusion MR imaging for differentiation of benign and malignant meningiomas

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hao [University of Groningen, Department of Radiology, University Medical Center Groningen, Groningen (Netherlands); Shanghai Jiaotong University, Department of Radiology, First People' s Hospital, Shanghai (China); Roediger, Lars A.; Oudkerk, Matthijs [University of Groningen, Department of Radiology, University Medical Center Groningen, Groningen (Netherlands); Shen, Tianzhen [Fudan University, Department of Radiology, Huashan Hospital, Shanghai (China); Miao, Jingtao [Shanghai Jiaotong University, Department of Radiology, First People' s Hospital, Shanghai (China)

    2008-06-15

    Our purpose was to determine whether perfusion MR imaging can be used to differentiate benign and malignant meningiomas on the basis of the differences in perfusion of tumor parenchyma and/or peritumoral edema. A total of 33 patients with preoperative meningiomas (25 benign and 8 malignant) underwent conventional and dynamic susceptibility contrast perfusion MR imaging. Maximal relative cerebral blood volume (rCBV) and the corresponding relative mean time to enhance (rMTE) (relative to the contralateral normal white matter) in both tumor parenchyma and peritumoral edema were measured. The independent samples t-test was used to determine whether there was a statistically significant difference in the mean rCBV and rMTE ratios between benign and malignant meningiomas. The mean maximal rCBV values of benign and malignant meningiomas were 7.16{+-}4.08 (mean{+-}SD) and 5.89{+-}3.86, respectively, in the parenchyma, and 1.05{+-}0.96 and 3.82{+-}1.39, respectively, in the peritumoral edema. The mean rMTE values were 1.16{+-}0.24 and 1.30{+-}0.32, respectively, in the parenchyma, and 0.91{+-}0.25 and 1.24{+-}0.35, respectively, in the peritumoral edema. The differences in rCBV and rMTE values between benign and malignant meningiomas were not statistically significant (P>0.05) in the parenchyma, but both were statistically significant (P<0.05) in the peritumoral edema. Perfusion MR imaging can provide useful information on meningioma vascularity which is not available from conventional MRI. Measurement of maximal rCBV and corresponding rMTE values in the peritumoral edema is useful in the preoperative differentiation between benign and malignant meningiomas. (orig.)

  8. Application of CT perfusion imaging in radiotherapy for lung cancer

    International Nuclear Information System (INIS)

    Xia Guangrong; Liu Guimei; He Wen; Jin Guohua; Xie Ruming; Xu Yongxiang; Li Xiaobo; Li Xuebing

    2011-01-01

    Objective: To investigate the value of CT perfusion imaging in evaluation of therapeutic effect and prognosis in radiotherapy for lung cancer. Methods: Fifty-one cases of lung cancer who were unable or refused to be operated on, 36 males and 15 females, aged 37-80, underwent CT perfusion imaging, 29 of which only before radiotherapy and 22 before and after radiotherapy twice. The images were collected by cine dynamic scanning (5 mm/4 slices) and input into the GE AW4.0 workstation for data processing. The slice positions of CT imaging were determined according to the largest tumor size in CT scan. Regions of interest of tumor were drawn at the region corresponding to the original images of CT perfusion. Radiotherapy was performed after CT perfusion imaging. Relevant parameters, including blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability surface (PS) were calculated. The treatment response after radiotherapy was evaluated by RECIST. At 2 -4 weeks after the treatment, CT examination was conducted once more. Results: The tests of the 51 patients showed that the BV was 13.6 ml·100 g -1 , the BF was 129.5 ml·min -1 ·100 g -1 , the MTT was 9.1 s, and the PS was 10.0 ml· min -1 · 100 g -1 before radiotherapy. The tests of the 22 of the 51 patients showed that the values of BV and BF after radiotherapy were 7.6 ml· 100 g -1 and 97.8 ml·min -1 · 100 g -1 , respectively, both lower than those before radiotherapy (11.2 and 108.7 ml·min -1 ·100 g -1 , respectively), however, both not significantly (t=1.28, 0.40, P>0.05); and the values of MTT and PS after radiotherapy were 8.9 s and 7.8 ml·min -1 · 100 g -1 , respectively, both not significantly higher than those before radiotherapy (7.2 s and 6.8 ml· min -1 · 100 g -1 , respectively, t=-1.15, -0.57, P>0.05). The mean area of tumor after radiotherapy was 1189.6 mm 2 , significantly less than that before radiotherapy (1920.3 mm 2 , t=3.98, P<0.05). The MTT of the SCLC patients was 12

  9. Assmentment of myocardial perfusion by magnetic resonance imaging: on the way to clinical application

    International Nuclear Information System (INIS)

    Fischer, S.E.; Lorenz, C.H.

    1997-01-01

    Magnetic resonance imaging detects the flow of contrast - enhanced blood and even allows the quantitative assessment of myocardial perfusion. The clinical application of this method is being held back by the difficulties in image evaluation and the limitation of standard techniques to the acquisition of a single slice per heart beat cycle. Recent developments in scanner hardware as well as in image acquisition techniques open up the possibility of assessing myocardial perfusion over the entire heart with a spatial resolution in the range of 2 mm. As an example of such a new scanning strategy, a segmented gradient-echo recalled echo planar imaging sequence with preceding saturation is discussed and results in a patient with an infarction are presented. The clinical use of perfusion assessment covering the entire heart for the diagnosis of coronary artery disease is enhanced by the flexibility of magnetic resonance imaging for the assessment of functional cardiac parameters. (orig.) [de

  10. Effects of isoproterenol on distribution of perfusion in embolized dog lungs

    International Nuclear Information System (INIS)

    Shepard, J.W. Jr.; Hauer, D.; Sgroi, V.; Moser, K.M.

    1979-01-01

    In 19 mechanically ventilated, anesthetized dogs, autologous venous thrombi were formed in the inferior vena cava and subsequently released. Serial perfusion lung scintigrams revealed the postembolic distribution of pulmonary blood flow before, during, and after the infusion of isoproterenol at 2.2 μg/min. Isoproterenol failed to restore perfusion to embolically occluded regions. When reperfusion occurred it was attributable to clot resolution. Gas exchange and hemodynamic measurements obtained in seven thromboembolized animals showed no scan evidence of reperfusion during the isoproterenol infusion. After embolization, cardiac output increased from 1.7 to 2.6 liter/min (p 2 from 38.0 to 45.3 mm Hg (p 2 to 50.7 mm Hg, along with a decrease in pulmonary vascular resistance from the postembolic mean of 448 to 246 dynes.sec.cm -5 (p < 0.05). Perfusion defects following acute pulmonary thromboembolization are not altered by the infusion of the potent pulmonary vasodilator, isoproterenol. Infusion of this drug following thromboembolization may have potential therapeutic benefit by reducing pulmonary vascular resistance, increasing cardiac output, and elevating the mixed-venous oxygen tension

  11. Assessment of femoral head perfusion by dynamic MR imaging

    International Nuclear Information System (INIS)

    Ochi, Ryuya; Nakano, Tetsuo; Miyazono, Kazuki; Tsurugami, Hiroshi; Fukuda, Tomohiro; Inaba, Daisuke; Takada, Koji

    2004-01-01

    We studied femoral head perfusion in 21 femoral neck fractures using dynamic MR imaging (MRI) between November 2001 and July 2002. MRI patterns divided into four groups when the results between the fractured side and unaffected side were compared. Femoral head perfusion at the fractured side was normal in Type A, about half in Type B, and absent in Type C. When perfusion at both the fractured side and unaffected side was absent, Exceptional Type was suspected. The Garden I group consisted of one Type B. The Garden II group consisted of one Type A, six Type B, one Type C, and two Exceptional Type. The Garden III group consisted of two Type B and one Type C, and the Garden IV group consisted of six Type C and one Exceptional Type. Post operations of by internal fixation confirmed the incidence of aseptic necrosis using MRI. (author)

  12. Lung perfusion characteristics in pulmonary arterial hypertension (PAH) and peripheral forms of chronic thromboembolic pulmonary hypertension (pCTEPH): Dual-energy CT experience in 31 patients

    Energy Technology Data Exchange (ETDEWEB)

    Giordano, Jessica; Khung, Suonita; Remy, Jacques; Remy-Jardin, Martine [Hospital Calmette (EA 2694), Department of Thoracic Imaging, Lille (France); Duhamel, Alain [University Lille, CHU Lille, Department of Biostatistics, Lille (France); Hossein-Foucher, Claude; Bellevre, Dimitri [University Lille, CHU Lille, Department of Nuclear Medicine, Hospital Salengro, Lille (France); Lamblin, Nicolas [University Lille, CHU Lille, Department of Cardiology, Cardiology Hospital, Lille (France)

    2017-04-15

    To compare lung perfusion in PAH and pCTEPH on dual-energy CT (DECT) examinations. Thirty-one patients with PAH (group 1; n = 19) and pCTEPH (group 2; n = 12) underwent a dual-energy chest CTA with reconstruction of diagnostic and perfusion images. Perfusion alterations were analysed at a segmental level. V/Q scintigraphy was available in 22 patients (group 1: 13/19; group 2: 9/12). CT perfusion was abnormal in 52.6 % of group 1 patients and in 100 % of group 2 patients (p = 0.0051). The patterns of perfusion alteration significantly differed between the two groups (p < 0.0001): (1) in group 1, 96.6 % of segments with abnormal perfusion showed patchy defects; (2) in group 2, the most frequent abnormalities consisted of patchy (58.5 %) and PE-type (37.5 %) defects. Paired comparison of CT perfusion and scintigraphy showed concordant findings in 76.9 % of group 1 (10/13) and 100 % of group 2 (9/9) patients, with a predominant or an exclusive patchy pattern in group 1 and a mixed pattern of abnormalities in group 2. Lung perfusion alterations at DECT are less frequent and more homogeneous in PAH than in pCTEPH, with a high level of concordant findings with V/Q scintigraphy. (orig.)

  13. Wedge and subselective pulmonary angiography in pulmonary hypertension secondary to venous obstruction

    International Nuclear Information System (INIS)

    Bowen, J.S.; Bookstein, J.J.; Johnson, A.D.; Peterson, K.L.; Moser, K.M.

    1985-01-01

    Pulmonary wedge or subselective angiography provided key diagnostic information in two cases of pulmonary hypertension secondary to pulmonary venous obstruction. Whereas conventional pulmonary angiograms and ventilation-perfusion lung scans were interpreted as showing embolism, plain radiographs demonstrated Kerley B lines, suggesting venous obstruction. Subselective or wedge angiography of nonopacified arteries verified their anatomical patency and also revealed venous stenoses, collaterals, and atrophy indicative of obstruction

  14. Tc-99m-MIBI Uptake in Active Pulmonary Tuberculosis: A Case Report

    International Nuclear Information System (INIS)

    Lee, Chang Ho; Park, Chan Hee; Hwang, Hee Sung; Bae, Moon Sun

    1996-01-01

    Technetium-99m MIBI was developed as a myocardiac perfusion imagine agent and has been used effectively in the detection and post-therapeutic evaluation of various neoplasm such as thyroid, lung, bone and breast tumors. As an infrequent findings, Tc-99m MIBI agent has shown in non-neoplastic pulmonary conditions including fibroding alveolitis, pulmonary actinomycosis, active pulmonary sarcoidosis, pulmonary interstitial fibrosis in progressive systemic sclerosis and active osteomyelitis. In a recent report conducted by Cetin Oncel, Tc-99m MIBI imaging is an effective method in the detection and follow-up of pulmonary tuberculosis. We have also experienced Tc-99m-MIBI uptake in active pulmonary tuberculosis incidentally found in a patient with suspected proliferative villonodular synovitis of the left ankle.

  15. Brain perfusion image using N-isopropyl-p-[123I] iodoamphetamine

    International Nuclear Information System (INIS)

    Matsuda, Hiroshi; Seki, Hiroyasu; Ishida, Hiroko

    1984-01-01

    In brain perfusion images using N-Isopropyl-p-[ 123 I] Iodoamphetamine and rotating gamma camera emission computed tomography, brain maps showing laterality indices (LI) were made for the purpose of detecting ineterhemispheric differences. Left (L) and right (R) leteral images were made by adding sagittal section images in each hemisphere, respectively. LI was calculated as follows. LI=100(1+(R-L)/(R+L)). The normal ranges (mean+-2 s.d.) of the indices determined by those obtained in five normal right-handed subjects were 103+-4 and 103+-10 for brain mean and each pixel, respectively. Out of 25 measurements in 22 righthanded patients with cerebrovascular accidents, brain mean LI beyond the normal limits and areas showing abnormal regional LI were observed in 5 (20%) and 21 (84%) measurements, respectively. On the other hand, X-ray CT showed low density areas in only 12 (48%). These brain maps were clinically useful for detecting and quantifying interhemispheric differences in brain perfusion images with N-Isopropyl-p-[ 123 I] Iodoamphetamine. (author)

  16. Brain perfusion: computed tomography applications

    International Nuclear Information System (INIS)

    Miles, K.A.

    2004-01-01

    Within recent years, the broad introduction of fast multi-detector computed tomography (CT) systems and the availability of commercial software for perfusion analysis have made cerebral perfusion imaging with CT a practical technique for the clinical environment. The technique is widely available at low cost, accurate and easy to perform. Perfusion CT is particularly applicable to those clinical circumstances where patients already undergo CT for other reasons, including stroke, head injury, subarachnoid haemorrhage and radiotherapy planning. Future technical developments in multi-slice CT systems may diminish the current limitations of limited spatial coverage and radiation burden. CT perfusion imaging on combined PET-CT systems offers new opportunities to improve the evaluation of patients with cerebral ischaemia or tumours by demonstrating the relationship between cerebral blood flow and metabolism. Yet CT is often not perceived as a technique for imaging cerebral perfusion. This article reviews the use of CT for imaging cerebral perfusion, highlighting its advantages and disadvantages and draws comparisons between perfusion CT and magnetic resonance imaging. (orig.)

  17. Application of a Simplified Method for Estimating Perfusion Derived from Diffusion-Weighted MR Imaging in Glioma Grading.

    Science.gov (United States)

    Cao, Mengqiu; Suo, Shiteng; Han, Xu; Jin, Ke; Sun, Yawen; Wang, Yao; Ding, Weina; Qu, Jianxun; Zhang, Xiaohua; Zhou, Yan

    2017-01-01

    Purpose : To evaluate the feasibility of a simplified method based on diffusion-weighted imaging (DWI) acquired with three b -values to measure tissue perfusion linked to microcirculation, to validate it against from perfusion-related parameters derived from intravoxel incoherent motion (IVIM) and dynamic contrast-enhanced (DCE) magnetic resonance (MR) imaging, and to investigate its utility to differentiate low- from high-grade gliomas. Materials and Methods : The prospective study was approved by the local institutional review board and written informed consent was obtained from all patients. From May 2016 and May 2017, 50 patients confirmed with glioma were assessed with multi- b -value DWI and DCE MR imaging at 3.0 T. Besides conventional apparent diffusion coefficient (ADC 0,1000 ) map, perfusion-related parametric maps for IVIM-derived perfusion fraction ( f ) and pseudodiffusion coefficient (D*), DCE MR imaging-derived pharmacokinetic metrics, including K trans , v e and v p , as well as a metric named simplified perfusion fraction (SPF), were generated. Correlation between perfusion-related parameters was analyzed by using the Spearman rank correlation. All imaging parameters were compared between the low-grade ( n = 19) and high-grade ( n = 31) groups by using the Mann-Whitney U test. The diagnostic performance for tumor grading was evaluated with receiver operating characteristic (ROC) analysis. Results : SPF showed strong correlation with IVIM-derived f and D* ( ρ = 0.732 and 0.716, respectively; both P simplified method to measure tissue perfusion based on DWI by using three b -values may be helpful to differentiate low- from high-grade gliomas. SPF may serve as a valuable alternative to measure tumor perfusion in gliomas in a noninvasive, convenient and efficient way.

  18. Evaluation of ocular acupuncture on cerebral infarction with cerebral blood flow perfusion imaging

    International Nuclear Information System (INIS)

    Li Yuge; Gao Qinyi; Wang Shuang; Zhao Yong

    2008-01-01

    To evaluate the immediate effect of ocular acupuncture on patients, an method of SPECT image of cerebral blood flow daily stress test was established. 10 patients diagnosed as cerebral infarction by CT or MRI were tested. They all received 99 Tc m -ECD SPECT imaging at twice before and after ocular acupuncture. By means of image subtraction technique and semi-quantitative method of regional interesting area, the change of regional cerebral blood flow was observed between the two images. Under restful state perfusion of cerebral blood flow in 18 foci was low at the frontal lobe, the cerebellum, the basal ganglia and temporal lobe. After ocular acupuncture, the perfusions were obviously increased in 16 foci among them and the reactivity of the frontal lobe and the cerebellum to ocular acupuncture was higher, the average improvement rate of which was 55.15% and 53.06% respectively, lower in the basal ganglia and temporal lobe, the average improvement rate was 31.79% and 36.67% respectively. 99 Tc m -ECD SPECT cerebral perfusion image has some significant clinic value for evaluating the effect of ocular acupuncture to treating cerebral infarction. (authors)

  19. Factors affecting the lung perfused blood volume in patients with intrapulmonary clots after anti-coagulation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Munemasa, E-mail: radokada@yamaguchi-u.ac.jp [Department of Radiology, Yamaguchi University Graduate School of Medicine 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Masuda, Yu [4th Grade of 6-year Medicine Doctor Program, Department of Medicine, Yamaguchi University Faculty of Medicine and Health Sciences 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Nakashima, Yoshiteru [Department of Radiology, Yamaguchi Grand Medical Center, Oosaki 77, Hofu, Yamaguchi 747-8511 (Japan); Nomura, Takafumi; Nakao, Sei [Department of Radiology, Yamaguchi University Graduate School of Medicine 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Suga, Kazuyoshi [Department of Radiology, St Hills Hospital, Imamurakita 3-7-18, Ube, Yamaguchi 755-0155 (Japan); Kido, Shoji [Computer-aided Diagnosis and Biomedical Imaging Research Biomedical Engineering, Applied Medical Engineering Science Graduate School of Medicine, Yamaguchi University, Tokiwadai 2-16-1, Ube, Yamaguchi 755-8611 (Japan); Matsunaga, Naofumi [Department of Radiology, Yamaguchi University Graduate School of Medicine 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan)

    2015-08-15

    Highlights: • Dual-energy CT can provide morphological and functional lung images in the same examination. • The subsequent dual-energy CT demonstrates the increased whole lung perfused blood volume (V{sub 120}) despite the residual intrapulmonary clots after treatment in one examination. • The increased whole lung perfusion (V{sub 120}) and a decreased low perfusion volume (V{sub 5}) result in the improvement in the low perfusion rate (%V{sub 5}) in the patients with acute pulmonary embolism after treatment. - Abstract: Objectives: Factors affecting the improvement in the lung perfused blood volume (LPBV) were evaluated based on the presence of intrapulmonary clots (IPCs) after anti-coagulation therapy using 64-slice dual-energy CT. Materials and methods: 96 patients exhibiting venous thromboembolism underwent initial and repeated LPBV examinations between December 2008 and July 2014. Fifteen patients were excluded due to pulmonary comorbidities, and a total of 81 patients were included in this study. Acute pulmonary embolism (PE) was diagnosed in 46 of the patients (56.7%). LPBV images were three-dimensionally reconstructed with two threshold ranges: 1–120 HU (V{sub 120}) and 1–5 HU (V{sub 5}), and the relative value of V{sub 5} per V{sub 120} expressed as %V{sub 5}. These values were subsequently compared with indicators of the severity of PE, such as the D-dimer level, heart rate and CT measurements. This study was approved by the local ethics committee. Results: In patients with IPCs, the D-dimer, V{sub 5} and %V{sub 5}values were significantly larger (p ≤ 0.01) in the initial LPBV, although these differences disappeared in subsequent LPBV after treatment. The right ventricular (RV) diameter, RV/left ventricular (RV/LV) diameter ratio and %V{sub 5} values were also significantly reduced, whereas the V{sub 5} value did not significantly decrease (p = 0.07), but V{sub 120} value significantly increased (p < 0.001) after treatment. However, in

  20. Contrast-enhanced magnetic resonance imaging of pulmonary lesions: Description of a technique aiming clinical practice

    International Nuclear Information System (INIS)

    Koenigkam-Santos, Marcel; Optazaite, Elzbieta; Sommer, Gregor; Safi, Seyer; Heussel, Claus Peter; Kauczor, Hans-Ulrich

    2015-01-01

    To propose a technique for evaluation of pulmonary lesions using contrast-enhanced MRI; to assess morphological patterns of enhancement and correlate quantitative analysis with histopathology. Material and methods: Thirty-six patients were prospectively studied. Volumetric-interpolated T1W images were obtained during consecutive breath holds after bolus triggered contrast injection. Volume coverage of first three acquisitions was limited (higher temporal resolution) and last acquisition obtained at 4th min. Two radiologists individually evaluated the patterns of enhancement. Region-of-interest-based signal intensity (SI)-time curves were created to assess quantitative parameters. Results: Readers agreed moderately to substantially concerning lesions’ enhancement pattern. SI-time curves could be created for all lesions. In comparison to benign, malignant lesions showed higher values of maximum enhancement, early peak, slope and 4th min enhancement. Early peak >15% showed 100% sensitivity to detect malignancy, maximum enhancement >40% showed 100% specificity. Conclusions: The proposed technique is robust, simple to perform and can be applied in clinical scenario. It allows visual evaluation of enhancement pattern/progression together with creation of SI-time curves and assessment of derived quantitative parameters. Perfusion analysis was highly sensitive to detect malignancy, in accordance to what is recommended by most recent guidelines on imaging evaluation of pulmonary lesions

  1. Contrast-enhanced magnetic resonance imaging of pulmonary lesions: Description of a technique aiming clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Koenigkam-Santos, Marcel, E-mail: marcelk46@yahoo.com.br [Department of Diagnostic and Interventional Radiology, University of Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Radiology Department, German Cancer Research Center (Deutsches Krebsforschungszentrum – DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Department of Radiology, University Hospital of the School of Medicine of Ribeirao Preto, University of Sao Paulo, Avenida Bandeirantes 3900, Campus Universitario Monte Alegre, 14048 900 Ribeirao Preto, Sao Paulo (Brazil); Optazaite, Elzbieta, E-mail: optazaite@andrulis.eu [Diagnostic and Interventional Radiology with Nuclear Medicine, Chest Clinic (Thoraxklinik), University of Heidelberg, Amalienstraße 5, 69126 Heidelberg (Germany); Sommer, Gregor, E-mail: gregor.sommer@usb.ch [Clinic of Radiology and Nuclear Medicine, University Hospital Basel, Petersgraben 4, CH-4031 Basel (Switzerland); Safi, Seyer, E-mail: seyer.safi@gmail.com [Surgery Department, Chest Clinic (Thoraxklinik), University of Heidelberg, Amalienstraße 5, 69126 Heidelberg (Germany); Heussel, Claus Peter, E-mail: heussel@uni-heidelberg.de [Diagnostic and Interventional Radiology with Nuclear Medicine, Chest Clinic (Thoraxklinik), University of Heidelberg, Amalienstraße 5, 69126 Heidelberg (Germany); Translational Lung Research Center (TLRC), Member of the German Center for Lung Research (DZL), Im Neuenheimer Feld 350, 69120 Heidelberg (Germany); Kauczor, Hans-Ulrich, E-mail: hans-ulrich.kauczor@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University of Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Translational Lung Research Center (TLRC), Member of the German Center for Lung Research (DZL), Im Neuenheimer Feld 350, 69120 Heidelberg (Germany); and others

    2015-01-15

    To propose a technique for evaluation of pulmonary lesions using contrast-enhanced MRI; to assess morphological patterns of enhancement and correlate quantitative analysis with histopathology. Material and methods: Thirty-six patients were prospectively studied. Volumetric-interpolated T1W images were obtained during consecutive breath holds after bolus triggered contrast injection. Volume coverage of first three acquisitions was limited (higher temporal resolution) and last acquisition obtained at 4th min. Two radiologists individually evaluated the patterns of enhancement. Region-of-interest-based signal intensity (SI)-time curves were created to assess quantitative parameters. Results: Readers agreed moderately to substantially concerning lesions’ enhancement pattern. SI-time curves could be created for all lesions. In comparison to benign, malignant lesions showed higher values of maximum enhancement, early peak, slope and 4th min enhancement. Early peak >15% showed 100% sensitivity to detect malignancy, maximum enhancement >40% showed 100% specificity. Conclusions: The proposed technique is robust, simple to perform and can be applied in clinical scenario. It allows visual evaluation of enhancement pattern/progression together with creation of SI-time curves and assessment of derived quantitative parameters. Perfusion analysis was highly sensitive to detect malignancy, in accordance to what is recommended by most recent guidelines on imaging evaluation of pulmonary lesions.

  2. Perfusion MR imaging for differentiation of benign and malignant meningiomas

    International Nuclear Information System (INIS)

    Zhang, Hao; Roediger, Lars A.; Oudkerk, Matthijs; Shen, Tianzhen; Miao, Jingtao

    2008-01-01

    Our purpose was to determine whether perfusion MR imaging can be used to differentiate benign and malignant meningiomas on the basis of the differences in perfusion of tumor parenchyma and/or peritumoral edema. A total of 33 patients with preoperative meningiomas (25 benign and 8 malignant) underwent conventional and dynamic susceptibility contrast perfusion MR imaging. Maximal relative cerebral blood volume (rCBV) and the corresponding relative mean time to enhance (rMTE) (relative to the contralateral normal white matter) in both tumor parenchyma and peritumoral edema were measured. The independent samples t-test was used to determine whether there was a statistically significant difference in the mean rCBV and rMTE ratios between benign and malignant meningiomas. The mean maximal rCBV values of benign and malignant meningiomas were 7.16±4.08 (mean±SD) and 5.89±3.86, respectively, in the parenchyma, and 1.05±0.96 and 3.82±1.39, respectively, in the peritumoral edema. The mean rMTE values were 1.16±0.24 and 1.30±0.32, respectively, in the parenchyma, and 0.91±0.25 and 1.24±0.35, respectively, in the peritumoral edema. The differences in rCBV and rMTE values between benign and malignant meningiomas were not statistically significant (P>0.05) in the parenchyma, but both were statistically significant (P<0.05) in the peritumoral edema. Perfusion MR imaging can provide useful information on meningioma vascularity which is not available from conventional MRI. Measurement of maximal rCBV and corresponding rMTE values in the peritumoral edema is useful in the preoperative differentiation between benign and malignant meningiomas. (orig.)

  3. Imaging of pulmonary emphysema: A pictorial review

    Science.gov (United States)

    Takahashi, Masashi; Fukuoka, Junya; Nitta, Norihisa; Takazakura, Ryutaro; Nagatani, Yukihiro; Murakami, Yoko; Otani, Hideji; Murata, Kiyoshi

    2008-01-01

    The term ‘emphysema’ is generally used in a morphological sense, and therefore imaging modalities have an important role in diagnosing this disease. In particular, high resolution computed tomography (HRCT) is a reliable tool for demonstrating the pathology of emphysema, even in subtle changes within secondary pulmonary lobules. Generally, pulmonary emphysema is classified into three types related to the lobular anatomy: centrilobular emphysema, panlobular emphysema, and paraseptal emphysema. In this pictorial review, we discuss the radiological – pathological correlation in each type of pulmonary emphysema. HRCT of early centrilobular emphysema shows an evenly distributed centrilobular tiny areas of low attenuation with ill-defined borders. With enlargement of the dilated airspace, the surrounding lung parenchyma is compressed, which enables observation of a clear border between the emphysematous area and the normal lung. Because the disease progresses from the centrilobular portion, normal lung parenchyma in the perilobular portion tends to be preserved, even in a case of far-advanced pulmonary emphysema. In panlobular emphysema, HRCT shows either panlobular low attenuation or ill-defined diffuse low attenuation of the lung. Paraseptal emphysema is characterized by subpleural well-defined cystic spaces. Recent topics related to imaging of pulmonary emphysema will also be discussed, including morphometry of the airway in cases of chronic obstructive pulmonary disease, combined pulmonary fibrosis and pulmonary emphysema, and bronchogenic carcinoma associated with bullous lung disease. PMID:18686729

  4. The evaluation of dobutamine 99mTc-MIBI myocardial perfusion imaging in the diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    He Qing; Qu Wanying; Gong Junhui; Zhou Ying

    1996-01-01

    The method and the clinical value of dobutamine stress test as a substitute for exercise test in 99m Tc-MIBI myocardial perfusion imaging was investigated. 40 Patients were intravenously infused with dobutamine through IVAC syringe pumps by incremental doses, and 99m Tc-MIBI was injected at the peak dobutamine heart rate. The myocardial imaging was then performed. The rest myocardial imaging was done after 48 hours. 30 of the 31 patients with coronary heart disease showed reversible perfusion defects in dobutamine 99m Tc-MIBI myocardial perfusion images and 7 of the 9 patients without coronary heart disease showed normal images. The sensitivity of this test was 96.8% and the specificity 77.8%. None of the studies was discontinued due to dobutamine side effect. Dobutamine 99m Tc-MIBI myocardial perfusion imaging is a safe and sensitive method in the diagnosis of coronary heart disease

  5. Perfusion MR imaging of the heart with TrueFISP

    International Nuclear Information System (INIS)

    Schreiber, W.G.; Schmitt, M.; Kalden, P.; Mohrs, O.; Kreitner, K.F.; Thelen, M.; Horstick, G.; Gumbrich, T.; Petersen, S.; Voigtlaender, T.

    2001-01-01

    Objective: Development and test of a saturation-recovery TrueFISP (SR-Trufi) pulse sequence for myocardial perfusion MR imaging (MRI) using improved gradient hardware. Material and methods: Measurements were performed on a 1.5 T scanner with prototype gradients (50 mT/m, minimum rise time 300 μs). T 1 -weighted first-pass MRI of Gd-DTPA (0.025 μmol/kg) kinetics in the myocardium was performed using an SR-Trufi pulse sequence (T R /T E /α=2.6 ms/1.4 ms/55 ) with a saturation preparation of TD-30 ms before the TrueFISP readout. Measurements were performed in volunteers (n=4) and in a pig model of chronic ischemia (n=1). Results: In phantoms, the signal intensity was linear with contrast concentration up to 0.9 mmol/kg Gd-DTPA. MR images obtained with SR-Trufi had a good image quality and high spatial resolution of 2.1 mmx2.1 mm. Differences of the contrast agent's kinetics between a subendocardial perfusion deficit and neighboring myocardium were well visible on both MR images and signal-time curves derived from the region-of-interest analysis. Conclusion: SR-Trufi appears to be an interesting new technique for the assessment of myocardial microcirculation using dedicated cardiovascular MR systems. (orig.) [de

  6. Fully automated motion correction in first-pass myocardial perfusion MR image sequences.

    Science.gov (United States)

    Milles, Julien; van der Geest, Rob J; Jerosch-Herold, Michael; Reiber, Johan H C; Lelieveldt, Boudewijn P F

    2008-11-01

    This paper presents a novel method for registration of cardiac perfusion magnetic resonance imaging (MRI). The presented method is capable of automatically registering perfusion data, using independent component analysis (ICA) to extract physiologically relevant features together with their time-intensity behavior. A time-varying reference image mimicking intensity changes in the data of interest is computed based on the results of that ICA. This reference image is used in a two-pass registration framework. Qualitative and quantitative validation of the method is carried out using 46 clinical quality, short-axis, perfusion MR datasets comprising 100 images each. Despite varying image quality and motion patterns in the evaluation set, validation of the method showed a reduction of the average right ventricle (LV) motion from 1.26+/-0.87 to 0.64+/-0.46 pixels. Time-intensity curves are also improved after registration with an average error reduced from 2.65+/-7.89% to 0.87+/-3.88% between registered data and manual gold standard. Comparison of clinically relevant parameters computed using registered data and the manual gold standard show a good agreement. Additional tests with a simulated free-breathing protocol showed robustness against considerable deviations from a standard breathing protocol. We conclude that this fully automatic ICA-based method shows an accuracy, a robustness and a computation speed adequate for use in a clinical environment.

  7. Non-contrast-enhanced perfusion and ventilation assessment of the human lung by means of fourier decomposition in proton MRI.

    Science.gov (United States)

    Bauman, Grzegorz; Puderbach, Michael; Deimling, Michael; Jellus, Vladimir; Chefd'hotel, Christophe; Dinkel, Julien; Hintze, Christian; Kauczor, Hans-Ulrich; Schad, Lothar R

    2009-09-01

    Assessment of regional lung perfusion and ventilation has significant clinical value for the diagnosis and follow-up of pulmonary diseases. In this work a new method of non-contrast-enhanced functional lung MRI (not dependent on intravenous or inhalative contrast agents) is proposed. A two-dimensional (2D) true fast imaging with steady precession (TrueFISP) pulse sequence (TR/TE = 1.9 ms/0.8 ms, acquisition time [TA] = 112 ms/image) was implemented on a 1.5T whole-body MR scanner. The imaging protocol comprised sets of 198 lung images acquired with an imaging rate of 3.33 images/s in coronal and sagittal view. No electrocardiogram (ECG) or respiratory triggering was used. A nonrigid image registration algorithm was applied to compensate for respiratory motion. Rapid data acquisition allowed observing intensity changes in corresponding lung areas with respect to the cardiac and respiratory frequencies. After a Fourier analysis along the time domain, two spectral lines corresponding to both frequencies were used to calculate the perfusion- and ventilation-weighted images. The described method was applied in preliminary studies on volunteers and patients showing clinical relevance to obtain non-contrast-enhanced perfusion and ventilation data.

  8. The predictive value of preoperative perfusion/ventilation scintigraphy, spirometry and x-ray of the lungs on postoperative pulmonary complications. A prospective study

    International Nuclear Information System (INIS)

    Fogh, J.; Wille-Joergensen, P.; Brynjolf, I.; Thorup, J.; Joergensen, T.; Bording, L.; Kjaergaard, J.

    1987-01-01

    Prospectively, 125 patients were examined with 99m Tc-perfusion scintigraphy, 89m Kr- or 127 Xe-ventilation scintigraphy and chest radiogram prior to major surgery. Postoperative therapy-demanding pulmonary complications occurred in 18% of the patients. A statistical association could be demonstrated between all the preoperative tests except ventilation scintigraphy and the frequency of complications. However, the predictive values of each of the tests, or even the combined results, were not significantly different from the frequency of complications among all the patients. It is concluded that the predictive values of perfusion-and ventilation scintigraphy, spirometry and radiogram of the chest are too low to be of any practical use. (author)

  9. Comparative study of adenosine and exercise 201Tl myocardial perfusion tomographic imaging for detection of coronary heart disease

    International Nuclear Information System (INIS)

    Wang Xiong

    1997-01-01

    To compare diagnostic accuracy of adenosine and exercise 201 Tl myocardial perfusion tomographic imaging for detection of coronary heart disease (CHD) in patients with a normal rest ECG and no history of myocardial infarction, 81 patients with CHD and 10 normal control subjects underwent adenosine myocardial perfusion imaging, exercise nuclide myocardial perfusion imaging was performed in 117 patients with CHD and 16 normal control subjects, two groups also had coronary arteriography. Both exercise and adenosine testing parameters were analysed. It is shown: 1) The sensitivity and specificity for detection of CHD were 79% vs 80% for adenosine group and 81% vs 81% for exercise myocardial perfusion imaging group respectively. There was no significant difference in comparison with two matched groups (χ 2 = 1.13, χ 2 = 0.18, χ 2 = 0.12, P>0.05). 2) Side effects induced by adenosine accounted for 89% of patients, all symptoms were mild and disappeared quickly after the termination of the study except in 2 cases withdrawal of infusion needed because of severe angina pectoris. Adenosine myocardial perfusion imaging is a safe and sensitive method for detection of CHD. The diagnostic value of adenosine test is similar to that of exercise myocardial perfusion imaging and particularly useful in evaluating patients unable to perform exercise test or achieve adequate level of exercise

  10. Impact of residual pulmonary obstruction on the long-term outcome of patients with pulmonary embolism.

    Science.gov (United States)

    Pesavento, Raffaele; Filippi, Lucia; Palla, Antonio; Visonà, Adriana; Bova, Carlo; Marzolo, Marco; Porro, Fernando; Villalta, Sabina; Ciammaichella, Maurizio; Bucherini, Eugenio; Nante, Giovanni; Battistelli, Sandra; Muiesan, Maria Lorenza; Beltramello, Giampietro; Prisco, Domenico; Casazza, Franco; Ageno, Walter; Palareti, Gualtiero; Quintavalla, Roberto; Monti, Simonetta; Mumoli, Nicola; Zanatta, Nello; Cappelli, Roberto; Cattaneo, Marco; Moretti, Valentino; Corà, Francesco; Bazzan, Mario; Ghirarduzzi, Angelo; Frigo, Anna Chiara; Miniati, Massimo; Prandoni, Paolo

    2017-05-01

    The impact of residual pulmonary obstruction on the outcome of patients with pulmonary embolism is uncertain.We recruited 647 consecutive symptomatic patients with a first episode of pulmonary embolism, with or without concomitant deep venous thrombosis. They received conventional anticoagulation, were assessed for residual pulmonary obstruction through perfusion lung scanning after 6 months and then were followed up for up to 3 years. Recurrent venous thromboembolism and chronic thromboembolic pulmonary hypertension were assessed according to widely accepted criteria.Residual pulmonary obstruction was detected in 324 patients (50.1%, 95% CI 46.2-54.0%). Patients with residual pulmonary obstruction were more likely to be older and to have an unprovoked episode. After a 3-year follow-up, recurrent venous thromboembolism and/or chronic thromboembolic pulmonary hypertension developed in 34 out of the 324 patients (10.5%) with residual pulmonary obstruction and in 15 out of the 323 patients (4.6%) without residual pulmonary obstruction, leading to an adjusted hazard ratio of 2.26 (95% CI 1.23-4.16).Residual pulmonary obstruction, as detected with perfusion lung scanning at 6 months after a first episode of pulmonary embolism, is an independent predictor of recurrent venous thromboembolism and/or chronic thromboembolic pulmonary hypertension. Copyright ©ERS 2017.

  11. First-pass perfusion disturbance of coronary artery stenosis: an experimental study using MR imaging with Gd-DTPA enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Kyung Il; Lee, Young Ju [Ajou Univ. College of Medicine, Seoul (Korea, Republic of); Lim, Tae Hwan [Ulsan Univ. College of Medicine, Ulsan (Korea, Republic of)] [and others

    1997-11-01

    In order to determine the value of first-pass MR imaging in the diagnosis of myocardial ischemia, first-pass perfusion abnormality of coronary artery stenosis was observed in MRI after gadopentate dimeglumine(GD-DTPA) enhancement. The left anterior descending(LAD) coronary arteries of six dogs were subjected to approximately 70% stenosis confirmed by coronary angiography. Half an hour after adenosine and {sup 99m}Tc-sestamibi infusion, Gd-DTPA(0.2mmol/kg) and methylene blue were administered and termination was induced with potassium chloride. SE T1-weighted and single-photon emission computed tomography(SPECT) images were subsequently obtained and the findings of perfusion defect compared with specimen stain. Three dimensionally reconstructed MR images were used to measure signal intensity(SI) of normal myocardium and perfusion defect from their sectional and total volume. Five of six dogs with LAD artey stenosis ranging from 66% to 73% displayed perfusion defect on MRI, SPECT, and specimen stain, but the remaining dog with stenosis of 58% showed no such defect. MRI showed the perfusion defect as distinct low SI, enabling the measurement of percentage perfusion defect(24.4{+-}5.4%), which increased inferiorly. SI of normal myocardium and perfusion defect decreased inferiorly; their difference indicated stenosis-induced perfusion loss according to section location. Volumetric SI of normal myocardium and perfusion defect were 3.42{+-}0.52 and 2.16{+-}0.45, respectively(p<0.05). Gd-DTPA enhanced MRI displayed first-pass perfusion abnormality of coronary artery stenosis as perfusion defect with distinct low SI; this enabled the measurement of its volume and SI changes according to section location, and thus indicated the value of first-pass MR imaging in the diagnosis of myocardial ischemia.

  12. First-pass perfusion disturbance of coronary artery stenosis: an experimental study using MR imaging with Gd-DTPA enhancement

    International Nuclear Information System (INIS)

    Chung, Kyung Il; Lee, Young Ju; Lim, Tae Hwan

    1997-01-01

    In order to determine the value of first-pass MR imaging in the diagnosis of myocardial ischemia, first-pass perfusion abnormality of coronary artery stenosis was observed in MRI after gadopentate dimeglumine(GD-DTPA) enhancement. The left anterior descending(LAD) coronary arteries of six dogs were subjected to approximately 70% stenosis confirmed by coronary angiography. Half an hour after adenosine and 99m Tc-sestamibi infusion, Gd-DTPA(0.2mmol/kg) and methylene blue were administered and termination was induced with potassium chloride. SE T1-weighted and single-photon emission computed tomography(SPECT) images were subsequently obtained and the findings of perfusion defect compared with specimen stain. Three dimensionally reconstructed MR images were used to measure signal intensity(SI) of normal myocardium and perfusion defect from their sectional and total volume. Five of six dogs with LAD artey stenosis ranging from 66% to 73% displayed perfusion defect on MRI, SPECT, and specimen stain, but the remaining dog with stenosis of 58% showed no such defect. MRI showed the perfusion defect as distinct low SI, enabling the measurement of percentage perfusion defect(24.4±5.4%), which increased inferiorly. SI of normal myocardium and perfusion defect decreased inferiorly; their difference indicated stenosis-induced perfusion loss according to section location. Volumetric SI of normal myocardium and perfusion defect were 3.42±0.52 and 2.16±0.45, respectively(p<0.05). Gd-DTPA enhanced MRI displayed first-pass perfusion abnormality of coronary artery stenosis as perfusion defect with distinct low SI; this enabled the measurement of its volume and SI changes according to section location, and thus indicated the value of first-pass MR imaging in the diagnosis of myocardial ischemia

  13. Noninvasive estimation of pulmonary arterial pressure by analysis of pulmonary blood-flow distribution

    International Nuclear Information System (INIS)

    Konstam, M.A.; Strauss, H.W.; Alpert, N.M.; Miller, S.W.; Murphy, R.X.; Greene, R.E.; McKusick, K.A.

    1979-01-01

    To determine whether a correlation exists between pulmonary arterial (PA) pressure (P/sub a/) and the distribution of pulmonary blood flow, this distribution was measured in four upright dogs in the control state and during intravenous infusions of epinephrine or prostaglandin F/sub 2α/. During suspension of respiration, 15 mCi of Xe-133 were injected intravenously, and perfusion and equilibration lung images were recorded with a scintillation camera. The procedure was performed several times on each dog, with and without pharmacological elevation of PA pressure by 5 to 50 cm H 2 O. For each scintigram, the relative blood flow per unit ventilated lung volume (F) was plotted against centimeters above the hilum (h). Pulmonary arterial pressure was derived from each curve, assuming the relation F = B(P/sub a/ - hD) 2 , where B = constant and D = specific gravity of blood. Calculated PA pressure correlated strongly (r = 0.83) with measured PA pressure, suggesting a possible means of noninvasive estimation of PA pressure

  14. Diagnostic and clinical benefit of combined coronary calcium and perfusion assessment in patients undergoing PET/CT myocardial perfusion stress imaging.

    Science.gov (United States)

    Bybee, Kevin A; Lee, John; Markiewicz, Richard; Longmore, Ryan; McGhie, A Iain; O'Keefe, James H; Hsu, Bai-Ling; Kennedy, Kevin; Thompson, Randall C; Bateman, Timothy M

    2010-04-01

    A limitation of stress myocardial perfusion imaging (MPI) is the inability to detect non-obstructive coronary artery disease (CAD). One advantage of MPI with a hybrid CT device is the ability to obtain same-setting measurement of the coronary artery calcium score (CACS). Utilizing our single-center nuclear database, we identified 760 consecutive patients with: (1) no CAD history; (2) a normal clinically indicated Rb-82 PET/CT stress perfusion study; and (3) a same-setting CAC scan. 487 of 760 patients (64.1%) had subclinical CAD based on an abnormal CACS. Of those with CAC, the CACS was > or =100, > or =400, and > or =1000 in 47.0%, 22.4%, and 8.4% of patients, respectively. Less than half of the patients with CAC were receiving aspirin or statin medications prior to PET/CT imaging. Patients with CAC were more likely to be initiated or optimized on proven medical therapy for CAD immediately following PET/CT MPI compared to those without CAC. Subclinical CAD is common in patients without known CAD and normal myocardial perfusion assessed by hybrid PET/CT imaging. Identification of CAC influences subsequent physician prescribing patterns such that those with CAC are more likely to be treated with proven medical therapy for the treatment of CAD.

  15. A study of images of Projective Angles of pulmonary veins

    Energy Technology Data Exchange (ETDEWEB)

    Wang Jue [Beijing Anzhen Hospital, Beijing (China); Zhaoqi, Zhang [Beijing Anzhen Hospital, Beijing (China)], E-mail: zhaoqi5000@vip.sohu.com; Yu Wei; Miao Cuilian; Yan Zixu; Zhao Yike [Beijing Anzhen Hospital, Beijing (China)

    2009-09-15

    Aims: In images of magnetic resonance and computed tomography (CT) there are visible angles between pulmonary veins and the coronary, transversal or sagittal section of body. In this study these angles are measured and defined as Projective Angles of pulmonary veins. Several possible influential factors and characters of distribution are studied and analyzed for a better understanding of this imaging anatomic character of pulmonary veins. And it could be the anatomic base of adjusting correctly the angle of the central X-ray of the angiography of pulmonary veins undergoing the catheter ablation of atrial fibrillation (AF). Method: Images of contrast enhanced magnetic resonance angiography (CEMRA) and contrast enhanced computer tomography (CECT) of the left atrium and pulmonary veins of 137 health objects and patients with atrial fibrillation (AF) are processed with the technique of post-processing, and Projective Angles to the coronary and transversal sections are measured and analyzed statistically. Result: Project Angles of pulmonary veins are one of real and steady imaging anatomic characteristics of pulmonary veins. The statistical distribution of variables is relatively concentrated, with a fairly good representation of average value. It is possible to improve the angle of the central X-ray according to the average value in the selective angiography of pulmonary veins undergoing the catheter ablation of AF.

  16. Differentiating benign and malignant breast lesions with T2*-weighted first pass perfusion imaging

    International Nuclear Information System (INIS)

    Kvistad, K.A.; Smenes, E.; Haraldseth, O.; Lundgren, S.; Fjoesne, H.E.; Smethurst, H.B.

    1999-01-01

    Purpose: Invasive breast carcinomas and fibroadenomas are often difficult to differentiate in dynamic contrast-enhanced T1-weighted MR imaging of the breast, because both tumors can enhance strongly after contrast injection. The purpose of this study was to evaluate whether the addition of T2*-weighted first pass perfusion imaging can increase the differentiation of malignant from benign lesions. Material and Methods: Nine patients with invasive carcinomas and 10 patients with contrast enhancing fibroadenomas were examined by a dynamic contrast-enhanced T1-weighted 3D sequence immediately followed by a single slice T2*-weighted first pass perfusion sequence positioned in the contrast-enhancing lesion. Results: The carcinomas and the fibroadenomas were impossible to differentiate based on the contrast enhancement characteristics in the T1-weighted sequence. The signal loss in the T2*-weighted perfusion sequence was significantly stronger in the carcinomas than in the fibroadenomas (p=0.0004). Conclusion: Addition of a T2*-weighted first pass perfusion sequence with a high temporal resolution can probably increase the differentiation of fibroadenomas from invasive carcinomas in contrast-enhanced MR imaging of the breast. (orig.)

  17. Dynamic CT Perfusion Imaging for the Detection of Crossed Cerebellar Diaschisis in Acute Ischemic Stroke

    International Nuclear Information System (INIS)

    Jeon, Young Wook; Kim, Seo Hyun; Lee, Ji Young; Whang, Kum; Kim, Myung Soon; Kim, Young Ju; Lee, Myeong Sub; Brain Reserch Group

    2012-01-01

    Although the detection of crossed cerebellar diaschisis (CCD) by means of different imaging modalities is well described, little is known about its diagnosis by computed tomography perfusion (CTP) imaging. We investigated the detection rate of CCD by CTP imaging and the factors related to CCD on CTP images in patients with acute ischemic stroke. CT perfusion maps of cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and time-to-peak (TTP) obtained from 81 consecutive patients affected by an acute ischemic stroke were retrospectively reviewed. Whole-brain perfusion maps were obtained with a multichannel CT scanner using the toggling-table technique. The criteria for CCD was a unilateral supratentorial ischemic lesion and an accompanying decrease in perfusion of the contralateral cerebellar hemisphere on the basis of CTP maps by visual inspection without a set threshold. Maps were quantitatively analyzed in CCD positive cases. The criteria for CCD were fulfilled in 25 of the 81 cases (31%). Detection rates per CTP map were as follows: MTT (31%) > TTP (21%) > CBF (9%) > CBV (6%). Supratentorial ischemic volume, degree of perfusion reduction, and infratentorial asymmetry index correlated strongly (R, 0.555-0.870) and significantly (p < 0.05) with each other in CCD-positive cases. It is possible to detect CCD on all four of the CTP-based maps. Of these maps, MTT is most sensitive in detecting CCD. Our data indicate that CTP imaging is a valid tool for the diagnosis of CCD in patients affected by an acute hemispheric stroke.

  18. [Lung perfusion studies after percutaneous closure of patent ductus arteriosus using the Amplatzer Duct Occluder in children].

    Science.gov (United States)

    Parra-Bravo, José Rafael; Apolonio-Martínez, Adriana; Estrada-Loza, María de Jesús; Beirana-Palencia, Luisa Gracia; Ramírez-Portillo, César Iván

    2015-01-01

    The closure of patent ductus arteriosus with multiple devices has been associated with a reduction in lung perfusion. We evaluated the pulmonary perfusion after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder device using perfusion lung scan. Thirty patients underwent successful percutaneous patent ductus arteriosus occlusions using the Amplatzer Duct Occluder device were included in this study. Lung perfusion scans were preformed 6 months after the procedure. Peak flow velocities and protrusion of the device were analyzed by Doppler echocardiography. A left lung perfusionductus arteriosus and the minimum and maximum diameter/length of the ductus arteriosus ratio were statistically significant in patients with abnormalities of lung perfusion. It was observed protrusion the device in 6 patients with a higher maximum flow rate in the left pulmonary artery. The left lung perfusion may be compromised after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder. The increased flow velocity in the origin of the left pulmonary artery can be a poor indicator of reduction in pulmonary perfusion and can occur in the absence of protrusion of the device. Copyright © 2014 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  19. Clinical applications of brain perfusion imaging with sup 99m Tc-HM-PAO

    Energy Technology Data Exchange (ETDEWEB)

    Xiangtong, Lin [Shanghai Medical Univ. (China). Huashan Hospital; and others

    1989-11-01

    200 patients with central nervous system diseases were studied with {sup 99m}Tc-HM-PAO and SPECT, including Parkinson's disease (PD) 47, Vascular headache 69, CVD 34, Epilepsy 26, Head truma 10, Brain tumor 5 and other 9 cases. Part of them have been compared with the results of MRI, X-CT and EEG. The positivity of SPECT in PD is 61.7% with decrease perfusion in local area of cerebram and basal ganglia and only 4 cases had lower perfusion in cerebellum; in headache is 46.4%, showing variable perfusion patterns; in CVD is 79.4% with decrease perfusion, luxury perfusion and the phenomenon of 'diaschsis'. In epilepsy, the abnormal foci mostly localize in temporal lobe and have close relation to the results of EEG. In brain tumor it also denotes decreased uptake of tracer. The clinicl singnificance of brain perfusion imaging with {sup 99m}Tc-HM-PAO was discussed.

  20. Diagnostic value of dynamic perfusion MR imaging in benign and malignant musculoskeletal lesions

    International Nuclear Information System (INIS)

    Choi, Byeong Kyoo; Lee, Sang Hoon; Cha, Ji Hyeon; Kim, Sung Moon; Shin, Myung Jin; Han, Heon; Kim, Sam Soo; Lee, Ji Yeon; Jeon, Yong Hwan

    2008-01-01

    To assess the diagnostic value of dynamic perfusion MR imaging for differentiation between benign and malignant musculoskeletal lesions. Dynamic perfusion MR imaging was performed using a 3.0 T system in 32 female and 30 male patients (aged 10-90 years, mean age, 43 years). Following the assessment of the precontrast imaging, a dynamic study was performed. This dynamic technique allowed for 638 images to be obtained at 11 levels throughout the lesion. Twenty-eight lesions originated within bone (8 benign, 20 malignant), whereas 34 lesions were of soft tissue origin (22 benign, 12 malignant). The final diagnosis was histopathologically confirmed in all patients. To differentiate between benign and malignant lesions, we analyzed the four parameters: (maximal relative enhancement (MRE), time to peak (TTP), wash in rate (WI), steepest slope (SS) and the distribution of time intensity curve (TIC) patterns. The TTP, WI, and SS values of malignant lesions were statistically significant from those of benign lesions(ρ < 0.05). However, the difference for the MRE values was not statistically significant. The distribution of TIC patterns was a helpful indicator of benign or malignant state, however the difference between the two states was not significant. Dynamic perfusion MR imaging is a helpful tool in differentiating benign and malignant musculoskeletal lesions

  1. The role of pharmacological stress Tc-99m sestamibi myocardial perfusion imaging in an Australian population

    International Nuclear Information System (INIS)

    Howarth, D.M.; Booker, J.A.; Tan, T.S.K.; Bellamy, G.R.; Hardy, D.B.; Howarth, G.C.

    2003-01-01

    This observational study was performed in order to assess the exercise-related incremental diagnostic accuracy of Tc-99m sestamibi myocardial perfusion imaging (MPI) in a hospital-based Australian population, and to assess the relative roles of exercise and pharmacological stress in myocardial perfusion imaging (MPI). Two hundred and eight adult patients who had both Tc-99m sestamibi myocardial perfusion imaging and coronary angiography within a median time of 16 weeks were studied. The diagnostic end-point was coronary artery lesions of ≥50% and >70% stenosis detected on angiography. Using receiver operating characteristic curve analysis, the overall diagnostic accuracy was calculated, as well as the comparative accuracies in patients who undertook various levels of exercise stress testing (n=130) and those who received pharmacological (dipyridamole) stress testing (n=78). The overall respective diagnostic accuracy of Tc-99m sestamibi MPI for the diagnosis of coronary artery disease (>70% stenosis) was 81% and 76% when using the diagnostic criterion of ≥50% stenosis. On direct comparison of perfusion defects with angiographic stenoses, the respective sensitivity and specificity for the detection of >70% stenosis in each coronary artery territory was 73% and 79%. Pharmacological MPI showed a significantly greater sensitivity for the detection of localised stenoses compared to the overall group who had exercise MPI performed. Consequently, exercise stress MPI showed significantly more false negative lesions compared to dipyridamole stress imaging (p<0.003). However, a large proportion of patients were unable to perform to adequate exercise levels in this patient sample. We conclude that Tc-99m sestamibi myocardial perfusion imaging is an accurate non-invasive test for the diagnosis of coronary artery disease. Where any doubt exists as to the patient's ability to achieve exercise levels at or above 85% of the predicted value for age and gender, pharmacological

  2. Uptake of perfusion imaging agents by transplanted hearts: an experimental study in rats

    International Nuclear Information System (INIS)

    Bergsland, J.; Carr, E.A. Jr.; Carroll, M.; Feldman, M.J.; Kung, H.; Wright, J.R.

    1989-01-01

    There is a need for a reliable noninvasive marker of rejection in transplanted hearts. Endomyocardial biopsy is now the universally accepted diagnostic method of choice, but the invasiveness of the procedure and the limited size of the sample obtained makes this method far from ideal. As coronary blood flow may be expected to decrease during acute rejection, there has been interest in thallium-201 chloride (T1), a perfusion marker, as an imaging agent for diagnosing cardiac rejection. Hexakis(t-butylisonitrile)-technetium (Tc-TBI) is a representative of a new class of radiopharmaceuticals proposed as perfusion markers. We have compared the uptake of these imaging agents in a rat model of cardiac transplantation. Uptake of Tc-TBI as well as of T1 was significantly lower in rejecting than in nonrejecting hearts. This change was found in both left (LV) and right (RV) ventricles. Allografts in animals treated with cyclosporine (CyA) showed less severe rejection and higher uptakes of both imaging agents as compared to unmodified rejection. Our results suggest that perfusion imaging with these radionuclides is a potentially useful approach to the problem of detecting allograft rejection

  3. A decision support system improves the interpretation of myocardial perfusion imaging

    DEFF Research Database (Denmark)

    Tagil, K.; Bondouy, M.; Chaborel, J.P.

    2008-01-01

    PURPOSE: The aim of this study was to investigate the influence of a computer-based decision support system (DSS) on performance and inter-observer variability of interpretations regarding ischaemia and infarction in myocardial perfusion scintigraphy (MPS). METHODS: Seven physicians independently...... with the advice of the DSS showed less inter-observer variability than those made without advice. CONCLUSION: This study shows that a DSS can improve performance and reduces the inter-observer variability of interpretations in myocardial perfusion imaging. Both experienced and, especially, inexperienced...

  4. Detection of myocardial ischemia of hypertrophic cardiomyopathy with gated 99Tcm-MIBI myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Jia Peng; Guo Wanhua; Du Minghua; Gao Ling

    2010-01-01

    Objective: To evaluate the value of gated 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion imaging in detection of myocardial ischemia in hypertrophic cardiomyopathy. Methods: Sixty-nine patients with clinically proven hypertrophic cardiomyopathy were divided into 2 groups using coronary angiogram as 'gold standard': positive group (n=19, narrowing ≥ 50%) and negative group (n=50, narrowing 99 Tc m -MIBI myocardial perfusion imaging was performed and positive in all 69 patients (41 males, 28 females, aged 35-75 years). Comparative analysis between the two groups was carried out using t-test. Results: In the positive group, reversible and irreversible perfusion defects were detected in 9 and 10 patients, respectively. Left ventricular ejection fraction (LVEF) increased to (69.1 ± 2.8)% in 8 patients and decreased to (42.8 ± 2.1)% in 11 patients. In the negative group, reversible and irreversible perfusion defects were found in 37 and 13 patients, respectively. LVEF increased to (70.8 ± 4.0)% in 38 patients and decreased to (48.9 ± 2.7)% in 12 patients. The values of ischemic area, severity and extent of perfusion defect, and LVEF were significantly different between the two groups (t=9.28, 16.51, 2.65; P 99 Tc m -MIBI myocardial perfusion imaging is valuable in assessing patients with hypertrophic cardiomyopathy. Detection for the presence or absence of coexisting coronary artery disease and myocardial ischemia has an important prognostic indication and management indication for these patients. (authors)

  5. Value of diffusion-weighted MR imaging using various parameters for assessment and characterization of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Koyama, Hisanobu; Ohno, Yoshiharu; Seki, Shinichiro; Nishio, Mizuho; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Maniwa, Yoshimasa; Itoh, Tomoo; Nishimura, Yoshihiro; Sugimura, Kazuro

    2015-01-01

    Highlights: •Signal–intensity ratio evaluation between lesion and spinal cord is practical method. •Apparent diffusion coefficients may not contribute to the diagnosis of malignant. •True diffusion coefficients may have low potential for the differentiation. •Perfusion fractions may be less specific parameter of diagnosis of pulmonary nodule. •Choice of b values shows little impact for differentiation of pulmonary nodules. -- Abstract: Objectives: To determine the appropriate parameters and evaluation method for characterizing solitary pulmonary nodules (SPNs) using quantitative parameters of diffusion-weighted imaging (DWI). Methods: Thirty-two subjects with 36 SPNs underwent DWI with seven different b values (0, 50, 100, 150, 300, 500, and 1000 s/mm 2 ). Five quantitative parameters were obtained from the region of interest drawn over each SPN: apparent diffusion coefficients (ADCs), true diffusion coefficients (DCs), and perfusion fractions (PFs), and signal–intensity ratios between lesion and spinal cord from DWI (b values: 1000 [LSR 1000 ] and 500 [LSR 500 )]). All quantitative parameters and the diagnostic capabilities were statistically compared. Results: SPNs were diagnosed as follow: malignant (n = 27) and benign (n = 9). Parameter comparisons for malignant and benign showed both LSRs differed significantly (p < 0.05). Applying feasible threshold values showed LSR 500 specificity (88.9% [8/9]) and accuracy (77.8% [28/36]) were significantly higher than ADC, DC, and PF specificity and accuracy (p < 0.05). LSR 1000 accuracy (72.2% [26/36]) was significantly higher than DC accuracy, and its specificity (88.9% [8/9]) was significantly higher than ADC, DC, and PF specificities (p < 0.05). Conclusions: For quantitative differentiation of SPNs, LSR evaluation was more useful and practical than ADC, DC, and PF, and choice of b values showed little impact for the differentiation

  6. The impact of exercise myocardial perfusion SPECT imaging on the selection of patients for coronary angiography

    International Nuclear Information System (INIS)

    Song Liping; He Zuoxiang; Liu Xiujie; Shi Rongfang; Liu Yunzhong; Tian Yueqin; Zhang Xiaoli; Qin Xuewen; Chen Jilin; Gao Runlin

    2001-01-01

    Objective: Exercise 99 Tc m -MIBI myocardial perfusion SPECT is accurate for the diagnosis of coronary artery disease (CAD). This study assessed the impact of exercise myocardial perfusion imaging on the selection of patients for coronary angiography. Methods: 2188 consecutive patients who underwent exercise myocardial perfusion SPECT in authors' department in 1999 were retrospectively analyzed. Among them, 1807 were men, 381 women (average age: 53.5 +- 7.2 years). Overall, exercise myocardial SPECT was normal in 1731 patients, abnormal in 359 cases, and equivocal in 98 patients. There were 141 patients who underwent CAG within 60 days after myocardial SPECT. Results: Overall, 12% of the patients with abnormal SPECT imaging underwent coronary angiography, but only 5% of the patients with a normal SPECT imaging did (P < 0.001). Among these 141 patients who underwent coronary angiography, significant coronary stenosis was present in 91% of the patients who had had an abnormal SPECT imaging, but only 8% of those who had had a normal SPECT imaging (P < 0.001). In those patients who underwent coronary angiography, revascularization rate was 25% for the patients with abnormal SPECT imaging, but only 1% for the patients with a normal SPECT imaging. Conclusion: The results of exercise myocardial perfusion SPECT have a significant impact on the selection of patients for coronary angiography and revascularization

  7. Diffusion and perfusion imaging of bone marrow

    International Nuclear Information System (INIS)

    Biffar, Andreas; Dietrich, Olaf; Sourbron, Steven; Duerr, Hans-Roland; Reiser, Maximilian F.; Baur-Melnyk, Andrea

    2010-01-01

    In diffusion-weighted magnetic resonance imaging (DWI), the observed MRI signal intensity is attenuated by the self-diffusion of water molecules. DWI provides information about the microscopic structure and organization of a biological tissue, since the extent and orientation of molecular motion is influenced by these tissue properties. The most common method to measure perfusion in the body using MRI is T1-weighted dynamic contrast enhancement (DCE-MRI). The analysis of DCE-MRI data allows determining the perfusion and permeability of a biological tissue. DWI as well as DCE-MRI are established techniques in MRI of the brain, while significantly fewer studies have been published in body imaging. In recent years, both techniques have been applied successfully in healthy bone marrow as well as for the characterization of bone marrow alterations or lesions; e.g., DWI has been used in particular for the differentiation of benign and malignant vertebral compression fractures. In this review article, firstly a short introduction to diffusion-weighted and dynamic contrast-enhanced MRI is given. Non-quantitative and quantitative approaches for the analysis of DWI and semiquantitative and quantitative approaches for the analysis of DCE-MRI are introduced. Afterwards a detailed overview of the results of both techniques in healthy bone marrow and their applications for the diagnosis of various bone-marrow pathologies, like osteoporosis, bone tumors, and vertebral compression fractures are described.

  8. Application of EPI diffusion-weighted and Gd-DTPA T2* perfusion imaging in the diagnosis of brain ischemia

    International Nuclear Information System (INIS)

    Han Hongbin; Xie Jingxia

    1998-01-01

    Purpose: To study the MR and CT appearances of brain ischemia on diffusion-weighted imaging (DWI) and evaluate the role of EPI ADC-map, DWI and T 2 * perfusion imaging in acute stroke. Methods: DWI or ADC-map and routine T 1 WI and T 2 WI were performed in 36 patients with stroke (the time after onset of stroke: 2 hours - 2 months). Among them, 12 cases had perfusion imaging simultaneously. Results: Gd-DTPA T 2 * perfusion imaging demonstrated decrease of rrCBV and rrCBF in 10 cases; identical in 1 case and increase in 1 case. The mean transit time in the diseased area was longer than that of the contralateral corresponding region (paired t test: P 2 * perfusion imaging can demonstrate the decrease and restoration of CBF in the brain ischemic regions. DWI and ADC-map are highly valuable in the early diagnosis and monitoring the development of brain ischemic disease

  9. Dynamic image characteristics of pulmonary tuberculosis with diabetes mellitus

    International Nuclear Information System (INIS)

    Zhou Xinhua

    2000-01-01

    Objective: To analyze image characteristics of pulmonary tuberculosis associated with diabetes mellitus and observe the changes of pulmonary tuberculotic lesions influenced by the state of hyperglycosemia. Methods: Examinations of chest plain film and tomography were taken in 68 patients with pulmonary tuberculosis and diabetes, and additional CT scans were done in 38 patients among them. Radiological examinations of lung and blood sugar test were taken at the interval of 2, 3, and 4-6 months in all 68 patients under the treatment of regular blood sugar control and antituberculosis, which compared with 30 patients with pulmonary tuberculosis only. Results: The images of X-ray and CT showed major lesions of massive patchy shadow in 55 patients (80.9%), or multiple small patchy shadow in 13(19.1%) and cavity 61(89.7%). After 2 month's treatment, enlargement of patchy shadow and cavity were found in 9(23.7%)and 10(28.6%)cases, respectively with overall deterioration rates of 65.8% in group of 38 patients with level of blood sugar over 7.0 mmol/L, which was significantly higher than that of the control group 7.0 mmol/L(x 2 =16.4, P 2 = 0.81, P>0.5) with the well controlled blood sugar after treatment of 3 months or more. The follow-up images showed similar results between the groups of pulmonary tuberculosis only and the group of pulmonary tuberculosis with high level of blood sugar, in which the overall deterioration rates was significant less than the group of pulmonary tuberculosis with level of blood sugar more than 8.0 mmol/L(x 2 =5.46, P<0.025). Conclusion: There are imaging characteristics in patient with pulmonary tuberculosis and diabetes mellitus. The state of hyperglycosemia is a vital factor, which influences the radiological changes of pulmonary tuberculosis

  10. Ventilation/perfusion scintigraphy in children with post-infectious bronchiolitis obliterans: a pilot study.

    Directory of Open Access Journals (Sweden)

    Bo-Qia Xie

    Full Text Available PURPOSE: Childhood post-infectious bronchiolitis obliterans (BO is an infrequent lung disease leading to narrowing and/or complete obliteration of small airways. Ventilation and perfusion (V/Q scan can provide both regional and global pulmonary information. However, only few retrospective researches investigating post-infectious BO involved V/Q scan, the clinical value of this method is unknown. This preliminary prospective study was aimed to evaluate the correlation of V/Q scan with disease severity, pulmonary function test results, and prognosis in children with post-infectious BO. METHODS: Twenty-five post-infectious BO children (18 boys and 7 girls; mean age, 41 months underwent V/Q scan and pulmonary function tests. Patients were followed after their inclusion. Ventilation index and perfusion index obtained from V/Q scan were used to measure pulmonary abnormalities. Spearman's rank correlation test of ventilation index and perfusion index on disease severity, lung function tests indices, and follow-up results were performed. RESULTS: The median follow-up period was 4.6 years (range, 2.2 to 5.0 years. Ventilation index and perfusion index were both correlated with disease severity (r = 0.72, p<0.01 and r = 0.73, p<0.01, but only ventilation index was related to pulmonary function tests results (all p<0.05. In addition, Spearman test yielded significant correlations between perfusion index and prognosis (r = 0.77, p<0.01, and ventilation index and prognosis (r = 0.63, p = 0.01. CONCLUSIONS: For children with post-infectious BO, the present study preliminarily indicated that the degree of ventilation and perfusion abnormalities evaluated by V/Q scan may be used to assess disease severity, and may be predictive of patient's outcome.

  11. The value of lung scintigraphy in the diagnosis of pulmonary embolism

    NARCIS (Netherlands)

    van Beek, E. J.; Tiel-van Buul, M. M.; Büller, H. R.; van Royen, E. A.; ten Cate, J. W.

    1993-01-01

    The role of lung scintigraphy in the diagnostic management of patients with clinically suspected pulmonary embolism is reviewed. Evidence is provided that a normal perfusion scan excludes clinically relevant pulmonary embolism, and that a high probability lung scan, defined as a segmental perfusion

  12. Myocardial perfusion imaging: Lessons learned and work to be done-update.

    Science.gov (United States)

    Iskandrian, Ami E; Dilsizian, Vasken; Garcia, Ernest V; Beanlands, Rob S; Cerqueira, Manuel; Soman, Prem; Berman, Daniel S; Cuocolo, Alberto; Einstein, Andrew J; Morgan, Charity J; Hage, Fadi G; Schelbert, Heinrich R; Bax, Jeroen J; Wu, Joseph C; Shaw, Leslee J; Sadeghi, Mehran M; Tamaki, Nagara; Kaufmann, Philipp A; Gropler, Robert; Dorbala, Sharmila; Van Decker, William

    2018-02-01

    As the second term of our commitment to Journal begins, we, the editors, would like to reflect on a few topics that have relevance today. These include prognostication and paradigm shifts; Serial testing: How to handle data? Is the change in perfusion predictive of outcome and which one? Ischemia-guided therapy: fractional flow reserve vs perfusion vs myocardial blood flow; positron emission tomography (PET) imaging using Rubidium-82 vs N-13 ammonia vs F-18 Flurpiridaz; How to differentiate microvascular disease from 3-vessel disease by PET? The imaging scene outside the United States, what are the differences and similarities? Radiation exposure; Special issues with the new cameras? Is attenuation correction needed? Are there normal databases and are these specific to each camera system? And finally, hybrid imaging with single-photon emission tomography or PET combined with computed tomography angiography or coronary calcium score. We hope these topics are of interest to our readers.

  13. Methodology for ventilation/perfusion SPECT

    DEFF Research Database (Denmark)

    Bajc, Marika; Neilly, Brian; Miniati, Massimo

    2010-01-01

    Ventilation/perfusion single-photon emission computed tomography (V/Q SPECT) is the scintigraphic technique of choice for the diagnosis of pulmonary embolism and many other disorders that affect lung function. Data from recent ventilation studies show that the theoretic advantages of Technegas ov...

  14. Myocardial perfusion imaging with thalium 201 during and after exercise in patients with coronary heart

    Energy Technology Data Exchange (ETDEWEB)

    Bravo, P B; Villacorta, E V; Monzon, O P; Torres, Jr, J F; Guzman, S V

    1977-07-01

    A unique, non-invasive technique for the evaluation of the regional myocardial perfusion of patients with coronary heart disease has been developed. This entails the use of radionuclide, like thallium (Tl-201), which concentrates in the normal myocardium, leaving areas of ischemia or scarring or ''cold'' perfusion defects. Myocardial perfusion imaging in conjunction with graded exercise testing significantly increases the positivity of the stress test alone among patients with classic angina from 80% to 95%. It gives invaluable information as to the site and extent of the lesion and its reversibility. Among the patients with ECG Q waves indicative of previous infarction, image defects were detected in 93.7%; reversible ischemia co-existing with the infarction was also demonstrated.

  15. Application of a Simplified Method for Estimating Perfusion Derived from Diffusion-Weighted MR Imaging in Glioma Grading

    Directory of Open Access Journals (Sweden)

    Mengqiu Cao

    2018-01-01

    Full Text Available Purpose: To evaluate the feasibility of a simplified method based on diffusion-weighted imaging (DWI acquired with three b-values to measure tissue perfusion linked to microcirculation, to validate it against from perfusion-related parameters derived from intravoxel incoherent motion (IVIM and dynamic contrast-enhanced (DCE magnetic resonance (MR imaging, and to investigate its utility to differentiate low- from high-grade gliomas.Materials and Methods: The prospective study was approved by the local institutional review board and written informed consent was obtained from all patients. From May 2016 and May 2017, 50 patients confirmed with glioma were assessed with multi-b-value DWI and DCE MR imaging at 3.0 T. Besides conventional apparent diffusion coefficient (ADC0,1000 map, perfusion-related parametric maps for IVIM-derived perfusion fraction (f and pseudodiffusion coefficient (D*, DCE MR imaging-derived pharmacokinetic metrics, including Ktrans, ve and vp, as well as a metric named simplified perfusion fraction (SPF, were generated. Correlation between perfusion-related parameters was analyzed by using the Spearman rank correlation. All imaging parameters were compared between the low-grade (n = 19 and high-grade (n = 31 groups by using the Mann-Whitney U test. The diagnostic performance for tumor grading was evaluated with receiver operating characteristic (ROC analysis.Results: SPF showed strong correlation with IVIM-derived f and D* (ρ = 0.732 and 0.716, respectively; both P < 0.001. Compared with f, SPF was more correlated with DCE MR imaging-derived Ktrans (ρ = 0.607; P < 0.001 and vp (ρ = 0.397; P = 0.004. Among all parameters, SPF achieved the highest accuracy for differentiating low- from high-grade gliomas, with an area under the ROC curve value of 0.942, which was significantly higher than that of ADC0,1000 (P = 0.004. By using SPF as a discriminative index, the diagnostic sensitivity and specificity were 87.1% and 94

  16. Bull's-eye map of myocardial perfusion MR imaging. Comparison with SPECT

    International Nuclear Information System (INIS)

    Nomura, Yukihiro; Nanjo, Shuji; Yamazaki, Junichi; Yoshikawa, Kohki; Inoue, Yusuke

    2003-01-01

    When diagnosing heart disease, chest roentgenograms, ultrasonography, single-photon emission computed tomography (SPECT), and coronary arteriography are usually performed. Magnetic resonance (MR) imaging is not widely used for evaluating heart disease. Recent technological progress has allowed high quality images of the heart to be reliably obtained. A routine MR study taking about 30-40 minutes can provide a large amount of diagnostic information, such as cardiac structure, function, perfusion, and myocardial viability. The analysis software that can offer Bull's-eye maps from myocardial perfusion images has recently become commercially available. In this study, the characteristics of Bull's-eye mapping of MR imaging is compared with that of Bull's-eye mapping of SPECT using the same heart phantom. The difference in the image quality of the Bull's-eye maps was evaluated among the receiver coils of MR imaging. On Bull's-eye maps from both MR imaging and SPECT, decreased signal intensity was noted in the posterolateral wall. The degree of decrease in the signal of the MR imaging was more prominent than of SPECT. The decrease was severe for the general-purpose receive-only flexible (GPFLEX) coil, moderate for the cardiac and TORSO coil, and slight for the body coil. In the selection of a coil, it is necessary to take into consideration the trade-off between the distribution of signal intensity and the signal-to-noise ratio (SNR). (author)

  17. Clinical evaluation of 99Tcm-MIBI myocardial perfusion imaging for the detection of coronary artery disease in patients with metabolic syndrome

    International Nuclear Information System (INIS)

    Tian Yueqin; Wei Hongxing; Guo Xinhua; Guo Feng; He Zuoxiang

    2008-01-01

    Objective: Metabolic syndrome is a combination of medical disorders that consist of a collection of independent factors at risk of developing coronary artery disease. The purpose of this study was to evaluate the value of 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion imaging for the diagnosis of coronary artery disease in patients with metabolic syndrome. Methods: A total of 251 patients [mean age (59 ± 10) years, 179 men, 72 women] were included in this study. All patients underwent exercise and rest 99 Tc m -MIBI myocardial perfusion imaging and coronary angiography. Results: Of the 163 patients with significant coronary artery stenosis, 116 showed abnormal 99 Tc m -MIBI myocardial perfusion imaging; and among the 88 patients with normal coronary angiography, 82 showed normal myocardial perfusion imaging. The sensitivity, specificity and accuracy of 99 Tc m -MIBI myocardial perfusion imaging for coronary artery disease detection were 71% (116/163), 93% (82/88) and 79% (198/251), respectively. The positive and negative predictive values were 95% (116/122) and 64% (82/129), respectively. Conclusion: 99 Tc m -MIBI myocardial perfusion imaging has important clinical value for detecting coronary artery disease in patients with metabolic syndrome. (authors)

  18. Can perfusion SPECT aid CTPA interpretation?

    International Nuclear Information System (INIS)

    Gradinscak, D. J.; Roach, P.; Bailey, E.; Kueh, S.

    2009-01-01

    Full text:Objective: To determine whether fusion of perfusion SPECT and CTPA improves the diagnostic accuracy of CTPA. Methods: 35 patients with suspected PE who underwent both CTPA and SPECT V/Q within 48 hours were included. Of these, the majority (n=30) had PE as determined by the V/Q SPECT scan and the others (n=5) were negative for PE. The clinical reports of CTPA were reviewed and pulmonary emboli tabulated based on anatomical location. A second radiologist, blinded to the results of the clinical read and the V/Q SPECT scan, reviewed the CTPA with and without perfusion SPECT fusion for assistance. Results: A total 57 PE were reported on the clinical reports and 60 PE identified on the blinded read. Fused CTPA/perfursion SPECT images identified a further 5 PE not identified on the clinical read (8% increase) and 2 PE not identified on the blinded read (3% increase). The additional emboli detected resulted in a change in final diagnosis from PE negative to PE positive in 2 patients (6%) compared with the clinical read and 1 patient (3%) compared with the blinded read without SPECT fusion. Conclusion: Fused CTPA-SPECT perfusion improves the sensitivity of CTPA for the detection of PE in a small number of patients. Fused data may help guide the radiologist to identify sites of PE on CTPA.

  19. A Prospective Evaluation of T2-Weighted First-Pass Perfusion MR Imaging In Diagnosing Breast Neoplasms

    Institute of Scientific and Technical Information of China (English)

    XiaoJuanUu; RenyouZhai; TaoJiang; LiWang

    2004-01-01

    OBJECTIVE To compare the results from breast cancer patients who undergo T2-weighted first-pass perfusion imaging after dynamic contrast-enhanced T1-weighted imaging during the same examination,and to evaluate if T2-weighted imaging can provide additional diagnostic information over that obtained with Tl-weiahted imaaina.METHODS Twenty-nine patients with breast lesions verified by pathology (benign 12, malignant 17) underwent MR imaging with dynamic contrast-enhanced Tl-weighted imaging of the entire breasts,immediately followed by 6-sections of T2-weighted first-pass perfusion imaging of the lesions. The diagnostic indices were acquired by individual 3D Tl-weighted enhancement rate criterion and the T2 signalintensity loss rate criterion. The sensitivity and specificity were calculated and the 2 methods were compared.RESULTS With the dynamic contrast-enhanced T1-weighted imaging there was a significant differences breast lesions (t=2.563, P=0.016)overlap between the signal intensitybetween the benign and malignant However we found a considerable increase in the carcinomas and thatin the benign lesions, for a sensitivity of 94% and a specificity of 25%.With T2-weighted first-pass perfusion imaging, there was a very significant difference between the benign and malignant breast lesions(t=4.777,P<0.001), and the overlap between the signal intensity decrease in the carcinomas and that of the benign lesions on the T2-weighted images was less pronounced than the overlap in the T1-weighted images, for a sensitivity of 88% and a specificity of 75%.CONCLUSION T2-weighted first-pass perfusion imaging may help differentiate between benign and malignant breast lesions with a higher level of specificity. The combination of T1-weighted and T2-weighted imaging is feasible in a single patient examination and may improve breast MR imaging.

  20. Gadolinium-enhanced turbo FLASH MR imaging of renal perfusion and excretion

    International Nuclear Information System (INIS)

    Watanabe, A.; Teresi, L.M.; Herbst, M.; O'Sullivan, R.M.; Lee, R.; Smith, C.; Renner, J.; Rappaport, A.; Bradley, W.G. Jr.

    1990-01-01

    This paper describes a novel approach to MR imaging of renal perfusion and excretion using gadolinium-enhanced, T1-weighted TURBP, fast low-angle shot (FLASH) imaging. Five normal volunteers and four patients were studied on a 1.5-T imaging system. Time-intensity curves of the appearance of gadolinium in each kidney and the bladder were then generated. In normal volunteers, marked first-pass enhancement of renal cortex followed by renal pyramids and collecting systems could be demonstrated on the first-pass gadolinium images. Delayed images showed hyperintense gadolinium within the bladder

  1. Changes in ventilation–perfusion during and after an COPD exacerbation: an assessment using fluid dynamic modeling

    Directory of Open Access Journals (Sweden)

    Hajian B

    2018-03-01

    Full Text Available Bita Hajian,1 Jan De Backer,2 Wim Vos,2 Wouter H van Geffen,3 Paul De Winter,1 Omar Usmani,4 Tony Cahn,5 Huib AM Kerstjens,3 Massimo Pistolesi,6 Wilfried De Backer1 1Department of Respiratory Medicine, University Hospital Antwerp, Edegem, Belgium; 2FLUIDDA nv, Kontich, Belgium; 3Department of Respiratory Medicine, University Medical Center Groningen, Groningen, the Netherlands; 4Department of Pulmonology, Brompton Hospital, London, UK; 5GSK, London, UK; 6Department of Pulmonary Diseases, University of Firenze, Florence, Italy Introduction: Severe exacerbations associated with chronic obstructive pulmonary disease (COPD that require hospitalization significantly contribute to morbidity and mortality. Definitions for exacerbations are very broad, and it is unclear whether there is one predominant underlying mechanism that leads to them. Functional respiratory imaging (FRI with modeling provides detailed information about airway resistance, hyperinflation, and ventilation–perfusion (V/Q mismatch during and following an acute exacerbation. Materials and methods: Forty-two patients with COPD participating in a multicenter study were assessed by FRI, pulmonary function tests, and self-reported outcome measures during an acute exacerbation and following resolution. Arterial blood gasses and lung function parameters were measured. Results: A significant correlation was found between alveolar–arterial gradient and image-based V/Q (iV/Q, suggesting that iV/Q represents V/Q mismatch during an exacerbation (p<0.05. Conclusion: Recovery of an exacerbation is due to decreased (mainly distal airway resistance (p<0.05. Improvement in patient-reported outcomes were also associated with decreased distal airway resistance (p<0.05, but not with forced expiratory volume. FRI is, therefore, a sensitive tool to describe changes in airway caliber, ventilation, and perfusion during and after exacerbation. On the basis of the fact that FRI increased distal airway

  2. Myocardial perfusion magnetic resonance imaging using sliding-window conjugate-gradient HYPR methods in canine with stenotic coronary arteries.

    Science.gov (United States)

    Ge, Lan; Kino, Aya; Lee, Daniel; Dharmakumar, Rohan; Carr, James C; Li, Debiao

    2010-01-01

    First-pass perfusion magnetic resonance imaging (MRI) is a promising technique for detecting ischemic heart disease. However, the diagnostic value of the method is limited by the low spatial coverage, resolution, signal-to-noise ratio (SNR), and cardiac motion-related image artifacts. A combination of sliding window and conjugate-gradient HighlY constrained back-PRojection reconstruction (SW-CG-HYPR) method has been proposed in healthy volunteer studies to reduce the acquisition window for each slice while maintaining the temporal resolution of 1 frame per heartbeat in myocardial perfusion MRI. This method allows for improved spatial coverage, resolution, and SNR. In this study, we use a controlled animal model to test whether the myocardial territory supplied by a stenotic coronary artery can be detected accurately by SW-CG-HYPR perfusion method under pharmacological stress. Results from 6 mongrel dogs (15-25 kg) studies demonstrate the feasibility of SW-CG-HYPR to detect regional perfusion defects. Using this method, the acquisition time per cardiac cycle was reduced by a factor of 4, and the spatial coverage was increased from 2 to 3 slices to 6 slices as compared with the conventional techniques including both turbo-Fast Low Angle Short (FLASH) and echoplanar imaging (EPI). The SNR of the healthy myocardium at peak enhancement with SW-CG-HYPR (12.68 ± 2.46) is significantly higher (P < 0.01) than the turbo-FLASH (8.65 ± 1.93) and EPI (5.48 ± 1.24). The spatial resolution of SW-CG-HYPR images is 1.2 × 1.2 × 8.0 mm, which is better than the turbo-FLASH (1.8 × 1.8 × 8.0 mm) and EPI (2.0 × 1.8 × 8.0 mm). Sliding-window CG-HYPR is a promising technique for myocardial perfusion MRI. This technique provides higher image quality with respect to significantly improved SNR and spatial resolution of the myocardial perfusion images, which might improve myocardial perfusion imaging in a clinical setting.

  3. Diagnostic accuracy of unenhanced, contrast-enhanced perfusion and angiographic MRI sequences for pulmonary embolism diagnosis: results of independent sequence readings

    Energy Technology Data Exchange (ETDEWEB)

    Revel, Marie Pierre [Hopital Europeen Georges Pompidou, APHP, Departments of Radiology, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); Hotel-Dieu, Service de Radiologie, Paris (France); Sanchez, Olivier; Meyer, Guy [Hopital Europeen Georges Pompidou, APHP, Respiratory and intensive care and, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); INSERM Unite 765, Paris (France); Lefort, Catherine; Couchon, Sophie; Hernigou, Anne; Frija, Guy [Hopital Europeen Georges Pompidou, APHP, Departments of Radiology, Paris (France); Niarra, Ralph [Hopital Europeen Georges Pompidou, APHP, Clinical Epidemiology, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); Chatellier, Gilles [Hopital Europeen Georges Pompidou, APHP, Clinical Epidemiology, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); INSERM CIC-EC E4, Paris (France)

    2013-09-15

    To independently evaluate unenhanced, contrast-enhanced perfusion and angiographic MR sequences for pulmonary embolism (PE) diagnosis. Prospective investigation, including 274 patients who underwent perfusion, unenhanced 2D steady-state-free-precession (SSFP) and contrast-enhanced 3D angiographic MR sequences on a 1.5-T unit, in addition to CTA (CT angiography). Two independent readers evaluated each sequence independently in random order. Sensitivity, specificity, predictive values and inter-reader agreement were calculated for each sequence, excluding sequences judged inconclusive. Sensitivity was also calculated according to PE location. Contrast-enhanced angiographic sequences showed the highest sensitivity (82.9 and 89.7 %, reader 1 and reader 2, respectively), specificity (98.5 and 100 %) and agreement (kappa value 0.77). Unenhanced angiographic sequences, although less sensitive overall (68.7 and 76.4 %), were sensitive for the detection of proximal PE (92.7 and 100 %) and showed high specificity (96.1 and 99.1 %) and good agreement (kappa value 0.62). Perfusion sequences showed lower sensitivity (75.0 and 79.3 %), specificity (84.8 and 89.7 %) and agreement (kappa value 0.51), and a negative predictive value of 84.8 % at best. Compared with contrast-enhanced angiographic sequences, unenhanced sequences demonstrate lower sensitivity, except for proximal PE, but high specificity and agreement. The negative predictive value of perfusion sequences was insufficient to safely rule out PE. (orig.)

  4. Hypoxic pulmonary vasoconstriction in reptiles: a comparative study of four species with different lung structures and pulmonary blood pressures.

    Science.gov (United States)

    Skovgaard, Nini; Abe, Augusto S; Andrade, Denis V; Wang, Tobias

    2005-11-01

    Low O2 levels in the lungs of birds and mammals cause constriction of the pulmonary vasculature that elevates resistance to pulmonary blood flow and increases pulmonary blood pressure. This hypoxic pulmonary vasoconstriction (HPV) diverts pulmonary blood flow from poorly ventilated and hypoxic areas of the lung to more well-ventilated parts and is considered important for the local matching of ventilation to blood perfusion. In the present study, the effects of acute hypoxia on pulmonary and systemic blood flows and pressures were measured in four species of anesthetized reptiles with diverse lung structures and heart morphologies: varanid lizards (Varanus exanthematicus), caimans (Caiman latirostris), rattlesnakes (Crotalus durissus), and tegu lizards (Tupinambis merianae). As previously shown in turtles, hypoxia causes a reversible constriction of the pulmonary vasculature in varanids and caimans, decreasing pulmonary vascular conductance by 37 and 31%, respectively. These three species possess complex multicameral lungs, and it is likely that HPV would aid to secure ventilation-perfusion homogeneity. There was no HPV in rattlesnakes, which have structurally simple lungs where local ventilation-perfusion inhomogeneities are less likely to occur. However, tegu lizards, which also have simple unicameral lungs, did exhibit HPV, decreasing pulmonary vascular conductance by 32%, albeit at a lower threshold than varanids and caimans (6.2 kPa oxygen in inspired air vs. 8.2 and 13.9 kPa, respectively). Although these observations suggest that HPV is more pronounced in species with complex lungs and functionally divided hearts, it is also clear that other components are involved.

  5. The myocardial perfusion imaging of bone marrow mesenchymal stem cell transplantation treated acute myocardial infarction in pig

    International Nuclear Information System (INIS)

    He Miao; Hou Xiancun; Li Yaomei; Zhou Peng; Qi Chunmei; Wu Weihuan; Li Li

    2006-01-01

    Objective: To evaluate the clinical value of bone marrow mesenchymal stem cell transplantation on acute myocardial infarction in pig with myocardial perfusion imaging. Methods: Acute myocardial infarction models were established by 21 minitype Chinese pigs and were divided into two groups. After 10 days, experimental group (n=11) was transplanted with bone marrow mesenchymal stem cell at the infarct areas, and the control group (n=10) with incubation solution. Before and eight weeks after transplantation, both groups were examined by 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion imaging and with semi-quantitative analysis. Besides, echocardiogram and immunohistochemistry were also performed. Results: There was significant difference of total myocardial perfusion abnormal segments (46 vs 26), infarct areas [(34±12)% vs (21±10)%] and myocardial ischemia score [(20.0±4.3) vs (12.1±3.6)] between two groups (P<0.05). Also, there were accordant results with echocardiogram and immunohistochemistry findings. Conclusions: Bone marrow mesenchymal stem cell transplantation may improve blood perfusion and viability of the ischemic areas: Myocardial perfusion imaging can accurately observe the survival of bone marrow mesenchymal stem cell transplanted at the infarct areas. (authors)

  6. SU-C-201-04: Quantification of Perfusion Heterogeneity Based On Texture Analysis for Fully Automatic Detection of Ischemic Deficits From Myocardial Perfusion Imaging

    International Nuclear Information System (INIS)

    Fang, Y; Huang, H; Su, T

    2015-01-01

    Purpose: Texture-based quantification of image heterogeneity has been a popular topic for imaging studies in recent years. As previous studies mainly focus on oncological applications, we report our recent efforts of applying such techniques on cardiac perfusion imaging. A fully automated procedure has been developed to perform texture analysis for measuring the image heterogeneity. Clinical data were used to evaluate the preliminary performance of such methods. Methods: Myocardial perfusion images of Thallium-201 scans were collected from 293 patients with suspected coronary artery disease. Each subject underwent a Tl-201 scan and a percutaneous coronary intervention (PCI) within three months. The PCI Result was used as the gold standard of coronary ischemia of more than 70% stenosis. Each Tl-201 scan was spatially normalized to an image template for fully automatic segmentation of the LV. The segmented voxel intensities were then carried into the texture analysis with our open-source software Chang Gung Image Texture Analysis toolbox (CGITA). To evaluate the clinical performance of the image heterogeneity for detecting the coronary stenosis, receiver operating characteristic (ROC) analysis was used to compute the overall accuracy, sensitivity and specificity as well as the area under curve (AUC). Those indices were compared to those obtained from the commercially available semi-automatic software QPS. Results: With the fully automatic procedure to quantify heterogeneity from Tl-201 scans, we were able to achieve a good discrimination with good accuracy (74%), sensitivity (73%), specificity (77%) and AUC of 0.82. Such performance is similar to those obtained from the semi-automatic QPS software that gives a sensitivity of 71% and specificity of 77%. Conclusion: Based on fully automatic procedures of data processing, our preliminary data indicate that the image heterogeneity of myocardial perfusion imaging can provide useful information for automatic determination

  7. Evaluation in dogs of a new double-dose technique for imaging changes in myocardial perfusion

    International Nuclear Information System (INIS)

    Rothendler, J.A.; Okada, R.D.; Strauss, H.W.; Chesler, D.A.; Pohost, G.M.

    1984-01-01

    Assessment of myocardial perfusion with thallium immediately before and after an intervention that alters blood flow has been difficult due to presence of residual activity from the first tracer dose at the time of the second imaging. In a canine model the authors investigated a technique using two separate thallium injections during an intervention and after its reversal. Images were obtained after each injection, and a difference image was obtained by subtracting the first from the second image to correct for tracer persisting from the first injection. Interventions on coronary blood flow included: transient occlusion, subcritical stenosis with dipyridamole infusion, and permanent occlusion. The first images showed defects corresponding to the occlusion or stenosis, while the ''difference'' images correlated with myocardial perfusion at the time of the second injection

  8. Brain perfusion SPECT imaging before and during the acetazolamide test using sup 99m Tc-HMPAO

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, Hiroshi; Higashi, Sotaro; Kinuya, Keiko; Tsuji, Shiro; Sumiya, Hisashi; Hisada, Kinichi; Yamashita, Junkoh (Kanazawa Univ. (Japan). School of Medicine)

    1990-05-01

    A new method using brain perfusion {sup 99m}Tc-HMPAO SPECT imaging was developed for evaluating cerebral perfusion reserve by the acetazolamide test with a short period. The first SPECT study was carried out for 13.5 min to obtain SPECT images at the resting state after 3 min postinjection of 555 MBq (15 mCi) of {sup 99m}Tc-HMPAO. At the same time as the start of the first SPECT study, 1 g of acetazolamide was intravenously injected. Immediately after the stop of the 1st SPECT study, 925 MBq (25 mCi) of {sup 99m}Tc-HMPAO from the same vial as in the first study was additionally injected. Three minutes later the second SPECT study was carried out for 10 min. After reconstruction the tomographic images in the first study were subtracted from the images in the second study to obtain those during the acetazolamide test after correction of the time differences in data acquisition between the two studies. This subtraction technique gives independent brain perfusion SPECT images before and during the acetazolamide test. Besides, the regional flow changes during the test were quantitatively analyzed. In conclusion this method seems to be practically useful for evaluating regional brain perfusion before and during drug treatments as a consecutive study with a short period of approximately 30 min. (author).

  9. Cerebral misery perfusion diagnosed using hypercapnic blood-oxygenation-level-dependent contrast functional magnetic resonance imaging: a case report

    Directory of Open Access Journals (Sweden)

    D'Souza Olympio

    2010-02-01

    Full Text Available Abstract Introduction Cerebral misery perfusion represents a failure of cerebral autoregulation. It is an important differential diagnosis in post-stroke patients presenting with collapses in the presence of haemodynamically significant cerebrovascular stenosis. This is particularly the case when cortical or internal watershed infarcts are present. When this condition occurs, further investigation should be done immediately. Case presentation A 50-year-old Caucasian man presented with a stroke secondary to complete occlusion of his left internal carotid artery. He went on to suffer recurrent seizures. Neuroimaging demonstrated numerous new watershed-territory cerebral infarcts. No source of arterial thromboembolism was demonstrable. Hypercapnic blood-oxygenation-level-dependent-contrast functional magnetic resonance imaging was used to measure his cerebrovascular reserve capacity. The findings were suggestive of cerebral misery perfusion. Conclusions Blood-oxygenation-level-dependent-contrast functional magnetic resonance imaging allows the inference of cerebral misery perfusion. This procedure is cheaper and more readily available than positron emission tomography imaging, which is the current gold standard diagnostic test. The most evaluated treatment for cerebral misery perfusion is extracranial-intracranial bypass. Although previous trials of this have been unfavourable, the results of new studies involving extracranial-intracranial bypass in high-risk patients identified during cerebral perfusion imaging are awaited. Cerebral misery perfusion is an important and under-recognized condition in which emerging imaging and treatment modalities present the possibility of practical and evidence-based management in the near future. Physicians should thus be aware of this disorder and of recent developments in diagnostic tests that allow its detection.

  10. Prognostic value of gated 201Tl myocardial perfusion SPECT imaging in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Li Zicheng; Chen Xiaoming; Xu Hao

    2006-01-01

    Objective: To study the prognostic value of gated 201 Tl myocardial perfusion SPECT imaging in patients with coronary artery disease and assessment of therapy strategy for the individual patient. Methods: Eighty-four patients underwent rest and exercise stress 201 Tl gated myocardial perfusion SPECT imaging and were followed up for (32.92 ± 16.77) months. Images were studied using 17 segments and 1 to 4 scoring. Global summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS=SSS-SRS) were also calculated. Post-stress and rest ejection fraction (EF) were automatically measured. Results: Nine cardiac events occurred (3.90% per year). SSS, SDS, SRS and EF were the independent predictors of cardiac events (P 201 Tl myocardial perfusion SPECT imaging can provide prognostic assessment for the patients with coronary artery disease and guide in selection of therapeutic strategy. Among all of the indices SSS is the best predictors of cardiac events. (authors)

  11. Skin perfusion evaluation between laser speckle contrast imaging and laser Doppler flowmetry

    Science.gov (United States)

    Humeau-Heurtier, Anne; Mahe, Guillaume; Durand, Sylvain; Abraham, Pierre

    2013-03-01

    In the biomedical field, laser Doppler flowmetry (LDF) and laser speckle contrast imaging (LSCI) are two optical techniques aiming at monitoring - non-invasively - the microvascular blood perfusion. LDF has been used for nearly 40 years whereas LSCI is a recent technique that overcomes some drawbacks of LDF. Both LDF and LSCI give perfusion assessments in arbitrary units. However, the possible relationship existing between perfusions given by LDF and by LSCI over large blood flow values has not been completely studied yet. We therefore herein evaluate the relationship between the LDF and LSCI perfusion values across a broad range of skin blood flows. For this purpose, LDF and LSCI data were acquired simultaneously on the forearm of 12 healthy subjects, at rest, during different durations of vascular occlusion and during reactive hyperemia. For the range of skin blood flows studied, the power function fits the data better than the linear function: powers for individual subjects go from 1.2 to 1.7 and the power is close to 1.3 when all the subjects are studied together. We thus suggest distinguishing perfusion values given by the two optical systems.

  12. Identification of chronic thromboembolic pulmonary hypertension with MR imaging

    International Nuclear Information System (INIS)

    Gefter, W.B.; Palevsky, H.I.; Dinsmore, B.J.; Reichek, N.; DeRoos, A.; Kressel, H.Y.

    1988-01-01

    Thromboembolic pulmonary hypertension (TE-PHT) may be treatable by thromboendarterectomy. To evaluate the role of MR imaging in TE-PHT, the authors imaged eight patients with primary pulmonary hypertension or ASDs and seven patients with TE-PHT. Patients underwent conventional spin-echo (SE) imaging; three of seven patients with TE-PHT and eight of eight without emboli underwent cine MR studies. TE-PHT findings included focal areas of vessel wall thickening or plaquelike lesions in the central pulmonary arteries in six of seven. (Thrombus was not distinguished from flow-related signal in the seventh patient). Studies performed on three patients after thromboendarterectomy showed significant resolution of vascular lesions. Patients without emboli showed dilated central vessels without focal wall or lumen abnormality. Cine studies differentiated flow-related signal from thrombus, but wall thickening was better appreciated on SE images. MR imaging appears useful in identifying patients with TE-PHT who may benefit from surgery

  13. Validation of Fourier decomposition MRI with dynamic contrast-enhanced MRI using visual and automated scoring of pulmonary perfusion in young cystic fibrosis patients

    International Nuclear Information System (INIS)

    Bauman, Grzegorz; Puderbach, Michael; Heimann, Tobias; Kopp-Schneider, Annette; Fritzsching, Eva; Mall, Marcus A.; Eichinger, Monika

    2013-01-01

    Purpose: To validate Fourier decomposition (FD) magnetic resonance (MR) imaging in cystic fibrosis (CF) patients with dynamic contrast-enhanced (DCE) MR imaging. Materials and methods: Thirty-four CF patients (median age 4.08 years; range 0.16–30) were examined on a 1.5-T MR imager. For FD MR imaging, sets of lung images were acquired using an untriggered two-dimensional balanced steady-state free precession sequence. Perfusion-weighted images were obtained after correction of the breathing displacement and Fourier analysis of the cardiac frequency from the time-resolved data sets. DCE data sets were acquired with a three-dimensional gradient echo sequence. The FD and DCE images were visually assessed for perfusion defects by two readers independently (R1, R2) using a field based scoring system (0–12). Software was used for perfusion impairment evaluation (R3) of segmented lung images using an automated threshold. Both imaging and evaluation methods were compared for agreement and tested for concordance between FD and DCE imaging. Results: Good or acceptable intra-reader agreement was found between FD and DCE for visual and automated scoring: R1 upper and lower limits of agreement (ULA, LLA): 2.72, −2.5; R2: ULA, LLA: ±2.5; R3: ULA: 1.5, LLA: −2. A high concordance was found between visual and automated scoring (FD: 70–80%, DCE: 73–84%). Conclusions: FD MR imaging provides equivalent diagnostic information to DCE MR imaging in CF patients. Automated assessment of regional perfusion defects using FD and DCE MR imaging is comparable to visual scoring but allows for percentage-based analysis

  14. Validation of Fourier decomposition MRI with dynamic contrast-enhanced MRI using visual and automated scoring of pulmonary perfusion in young cystic fibrosis patients

    Energy Technology Data Exchange (ETDEWEB)

    Bauman, Grzegorz, E-mail: g.bauman@dkfz.de [German Cancer Research Center, Division of Medical Physics in Radiology, Im Neuenheimer Feld 223, 69120 Heidelberg (Germany); Puderbach, Michael, E-mail: m.puderbach@dkfz.de [Chest Clinics at the University of Heidelberg, Clinics for Interventional and Diagnostic Radiology, Amalienstr. 5, 69126 Heidelberg (Germany); Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (Germany); Heimann, Tobias, E-mail: t.heimann@dkfz.de [German Cancer Research Center, Division of Medical and Biological Informatics, Im Neuenheimer Feld 223, 69120 Heidelberg (Germany); Kopp-Schneider, Annette, E-mail: kopp@dkfz.de [German Cancer Research Center, Division of Biostatistics, Im Neuenheimer Feld 223, 69120 Heidelberg (Germany); Fritzsching, Eva, E-mail: eva.fritzsching@med.uni-heidelberg.de [University Hospital Heidelberg, Department of Translational Pulmonology and Division of Pediatric Pulmonology and Allergy and Cystic Fibrosis Center, Im Neuenheimer Feld 430, Heidelberg (Germany); Mall, Marcus A., E-mail: marcus.mall@med.uni-heidelberg.de [Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (Germany); University Hospital Heidelberg, Department of Translational Pulmonology and Division of Pediatric Pulmonology and Allergy and Cystic Fibrosis Center, Im Neuenheimer Feld 430, Heidelberg (Germany); Eichinger, Monika, E-mail: m.eichinger@dkfz.de [Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (Germany); German Cancer Research Center, Division of Radiology, Im Neuenheimer Feld 223, 69120 Heidelberg (Germany)

    2013-12-01

    Purpose: To validate Fourier decomposition (FD) magnetic resonance (MR) imaging in cystic fibrosis (CF) patients with dynamic contrast-enhanced (DCE) MR imaging. Materials and methods: Thirty-four CF patients (median age 4.08 years; range 0.16–30) were examined on a 1.5-T MR imager. For FD MR imaging, sets of lung images were acquired using an untriggered two-dimensional balanced steady-state free precession sequence. Perfusion-weighted images were obtained after correction of the breathing displacement and Fourier analysis of the cardiac frequency from the time-resolved data sets. DCE data sets were acquired with a three-dimensional gradient echo sequence. The FD and DCE images were visually assessed for perfusion defects by two readers independently (R1, R2) using a field based scoring system (0–12). Software was used for perfusion impairment evaluation (R3) of segmented lung images using an automated threshold. Both imaging and evaluation methods were compared for agreement and tested for concordance between FD and DCE imaging. Results: Good or acceptable intra-reader agreement was found between FD and DCE for visual and automated scoring: R1 upper and lower limits of agreement (ULA, LLA): 2.72, −2.5; R2: ULA, LLA: ±2.5; R3: ULA: 1.5, LLA: −2. A high concordance was found between visual and automated scoring (FD: 70–80%, DCE: 73–84%). Conclusions: FD MR imaging provides equivalent diagnostic information to DCE MR imaging in CF patients. Automated assessment of regional perfusion defects using FD and DCE MR imaging is comparable to visual scoring but allows for percentage-based analysis.

  15. A Case of Pulmonary Hypertension Due to Fistulas Between Multiple Systemic Arteries and the Right Pulmonary Artery in an Adult Discovered for Occulted Dyspnoea.

    Science.gov (United States)

    Li, Ji-Feng; Zhai, Zhen-Guo; Kuang, Tu-Guang; Liu, Min; Ma, Zhan-Hong; Li, Yi-Dan; Yang, Yuan-Hua

    2017-08-01

    Pulmonary hypertension (PH) can be caused by a fistula between the systemic and pulmonary arteries. Here, we report a case of PH due to multiple fistulas between systemic arteries and the right pulmonary artery where the ventilation/perfusion scan showed no perfusion in the right lung. A 32-year-old male patient was hospitalised for community-acquired pneumonia. After treatment with antibiotics, the pneumonia was alleviated but dyspnoea persisted. Pulmonary hypertension was diagnosed using right heart catheterisation, which detected the mean pulmonary artery pressure as 37mmHg. The anomalies were confirmed by contrast-enhanced CT scan (CT pulmonary angiography), systemic arterial angiography and pulmonary angiography. Following embolisation of the largest fistula, the haemodynamics and oxygen dynamics did not improve, and even worsened to some extent. After supportive therapy including diuretics and oxygen, the patient's dyspnoea, WHO function class and right heart function by transthoracic echocardiography all improved during follow-up. Pulmonary hypertension can be present even when the right lung perfusion is lost. Closure of fistulas by embolisation, when those fistulas act as the proliferating vessels, may be harmful. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  16. Relationship between deep venous thrombosis and pulmonary embolism by radionuclide techniques in 150 patients

    International Nuclear Information System (INIS)

    Shi, R.F.; Wang, X.M.; Liu, X.J.; Fang, W.

    2002-01-01

    Objective: This study was to evaluate the relationship between deep venous thrombosis and pulmonary embolism assessed by radionuclide imaging. Methods: One hundred and fifty patients with pulmonary embolism from September 1997 to September 2001 were included. Pulmonary perfusion/ventilation imaging and deep venous radionuclide venography was performed in all patients. There were 87 men, and 63 women, with an average age 39±18 years. Of them, 26 underwent pulmonary arteriography. Eleven patients had X Ray phleography of lower extremities, 18 patients had Impedence plethymography (IPG), and 36 patients had lower limb ultrasound study. Results: Out of 150 patients with pulmonary embolism, 128 (85.5%) had lower limb venous pathological changes. Among them, 100 patients had risk factors of deep venous thrombosis (78.3%). 120 patients had proximal vein (80.0%). The agreement between radionuclide venography and X Ray phleography of lower extremities UCG and IPG was 90.9%, 70.2% and 80.0% respectively. Conclusions: Our results indicate that DVT was one of most important cause for acute pulmonary embolism, and thrombosis is mostly located in the proximal veins

  17. Effects of acquisition time and reconstruction algorithm on image quality, quantitative parameters, and clinical interpretation of myocardial perfusion imaging

    DEFF Research Database (Denmark)

    Enevoldsen, Lotte H; Menashi, Changez A K; Andersen, Ulrik B

    2013-01-01

    time (HT) protocols and Evolution for Cardiac Software. METHODS: We studied 45 consecutive, non-selected patients referred for a clinically indicated routine 2-day stress/rest (99m)Tc-Sestamibi myocardial perfusion SPECT. All patients underwent an FT and an HT scan. Both FT and HT scans were processed......-RR) and for quantitative analysis (FT-FBP, HT-FBP, and HT-RR). The datasets were analyzed using commercially available QGS/QPS software and read by two observers evaluating image quality and clinical interpretation. Image quality was assessed on a 10-cm visual analog scale score. RESULTS: HT imaging was associated......: Use of RR reconstruction algorithms compensates for loss of image quality associated with reduced scan time. Both HT acquisition and RR reconstruction algorithm had significant effects on motion and perfusion parameters obtained with standard software, but these effects were relatively small...

  18. Current role of lung scintigraphy in pulmonary embolism

    International Nuclear Information System (INIS)

    Giordano, A.; Angiolillo, D. J.

    2001-01-01

    The pivotal role of lung scintigraphy in the diagnosis of pulmonary embolism (PE) has been questioned in recent years due to the introduction of spiral computed tomography. However, the scintigraphic results used for comparisons are often those of the authoritative PIOPED (Prospective Investigation of Pulmonary Embolism Diagnosis) study, carried out in the 1980s. Pulmonary scintigraphy has progressed from those years both in the methodological and interpretative fields, although perhaps too slowly. Results better than those of PIOPED's have been presented by study groups who used: 1) perfusion-only approach; 2) SPET imaging; 3) new interpretative criteria; 4) different prediction rules to integrate clinical and scintigraphic probabilities of PE. These advances are still insufficiently recognised by the nuclear medicine community, possibly due to a sort of PIOPED-based cultural globalisation. This paper reviews the actual advantages and limitations of nuclear medicine techniques, the diagnostic role of scintigraphy within the diagnostic algorithms proposed by international working groups and scientific societies and the results obtained from SPET imaging in the diagnosis of PE

  19. Pulmonary mineralization in four dogs with Cushing's syndrome

    International Nuclear Information System (INIS)

    Berry, C.R.; Ackerman, N.; Monce, K.

    1994-01-01

    The clinical and imaging features of four dogs with Cushing's syndrome and pulmonary mineralization are reviewed. Three dogs presented with a primary complaint of respiratory distress/dyspnea. Three dogs had pituitary dependent Cushing's syndrome, while the remaining one dog had iatrogenic Cushing's syndrome. Each dog had clinical features typical for Cushing's syndrome. Two of the dogs were euthanized due to progressive hypoxemia. In each dog, the serum calcium, phosphorous, blood urea nitrogen and creatinine were normal. A generalized increase in unstructured interstitial pulmonary opacity with diffuse mineralization was noted on thoracic radiographs of all dogs. In one dog, an ill-defined nodular interstitial pattern of mineralization was present. Delayed bone phase scintigraphy using 99m Technetium methylene diphosphonate documented generalized pulmonary uptake in two dogs. 99m Technetium labeled microaggregated albumin lung perfusion scans were normal in these two dogs. 99m Tc-MDP scintigraphy can provide useful information in diagnosing pulmonary mineralization in Cushingoid dogs

  20. Prognostic value of combined CT angiography and myocardial perfusion imaging versus invasive coronary angiography and nuclear stress perfusion imaging in the prediction of major adverse cardiovascular events

    DEFF Research Database (Denmark)

    Chen, Marcus Y.; Rochitte, Carlos E.; Arbab-Zadeh, Armin

    2017-01-01

    Purpose: To compare the prognostic importance (time to major adverse cardiovascular event [MACE]) of combined computed tomography (CT) angiography and CT myocardial stress perfusion imaging with that of combined invasive coronary angiography (ICA) and stress single photon emission CT myocardial p...

  1. Isolated left-sided pulmonary artery agenesis with left lung hypoplasia: A report of two cases

    Directory of Open Access Journals (Sweden)

    V Govindaraj

    2017-01-01

    Full Text Available Unilateral absence of pulmonary artery or pulmonary artery agenesis (UAPA is a rare congenital malformation that can present as an isolated lesion or in association with other cardiac anomalies. Though congenital, presentation in adults are also reported. Most common presentation in adults is of exercise intolerance. The developing lung on the affected side is hypoplastic. Diagnosis of UAPA is established by imaging methods like CT and MRI . There is no specific treatment for this condition. Treatment depends on patients symptomatology, presence of pulmonary hypertension and collateral circulation. Presence of pulmonary hypertension carries a bad prognosis. We present two adult patients with isolated left sided unilateral pulmonary artery agenesis with ipsilateral lung hypoplasia. The diagnosis was confirmed by CT chest and perfusion scan.

  2. Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study

    International Nuclear Information System (INIS)

    Nasis, Arthur; Ko, Brian S.; Leung, Michael C.; Antonis, Paul R.; Wong, Dennis T.; Kyi, Leo; Cameron, James D.; Meredith, Ian T.; Seneviratne, Sujith K.; Nandurkar, Dee; Troupis, John M.

    2013-01-01

    To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 ± 7.4 mSv compared with 13.2 ± 2.2 mSv for SPECT-MPI (P < 0.001). Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. (orig.)

  3. Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Nasis, Arthur; Ko, Brian S.; Leung, Michael C.; Antonis, Paul R.; Wong, Dennis T.; Kyi, Leo; Cameron, James D.; Meredith, Ian T.; Seneviratne, Sujith K. [Southern Health and Monash University, Monash Cardiovascular Research Centre, Monash Heart, Department of Medicine Monash Medical Centre (MMC), Melbourne (Australia); Nandurkar, Dee; Troupis, John M. [MMC, Southern Health, Department of Diagnostic Imaging, Melbourne (Australia)

    2013-07-15

    To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 {+-} 7.4 mSv compared with 13.2 {+-} 2.2 mSv for SPECT-MPI (P < 0.001). Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. (orig.)

  4. Perfusion of surgical cavity wall enhancement in early post-treatment MR imaging may stratify the time-to-progression in glioblastoma.

    Directory of Open Access Journals (Sweden)

    Ji Eun Park

    Full Text Available To determine if perfusion in surgical cavity wall enhancement (SCWE obtained in early post-treatment MR imaging can stratify time-to-progression (TTP in glioblastoma.This study enrolled 60 glioblastoma patients with more than 5-mm-thick SCWEs as detected on contrast-enhanced MR imaging after concurrent chemoradiation therapy. Two independent readers categorized the shape and perfusion state of SCWEs as nodular or non-nodular and as having positive or negative perfusion compared with the contralateral grey matter on arterial spin labeling (ASL. The perfusion fraction on ASL within the contrast-enhancing lesion was calculated. The independent predictability of TTP was analyzed using the Kaplan-Meier method and Cox proportional hazards modelling.The perfusion fraction was higher in the non-progression group, significantly for reader 2 (P = 0.03 and borderline significantly for reader 1 (P = 0.08. A positive perfusion state and (P = 0.02 a higher perfusion fraction of the SCWE were found to become an independent predictor of longer TTP (P = 0.001 for reader 1 and P < 0.001 for reader 2. The contrast enhancement pattern did not become a TTP predictor.Assessment of perfusion in early post-treatment MR imaging can stratify TTP in patients with glioblastoma for adjuvant temozolomide therapy. Positive perfusion in SCWEs can become a predictor of a longer TTP.

  5. Relationship between dynamic infrared thermal images and blood perfusion rate of the tongue in anaemia patients

    Science.gov (United States)

    Xie, Haiwei; Zhang, Yan

    2018-03-01

    The relationship between dynamic infrared (IR) thermal images and blood perfusion rate of the tongues of anaemia patients was investigated. Blood perfusion rates at multiple locations on the tongues of 62 anaemia patients and 70 control subjects were measured. For both groups of subjects, dynamic IR thermal images were also recorded within 16 s after the mouth opened. The results showed that the blood perfusion rates at different sites (apex, middle, left side and right side) on the tongues in anaemia patients (3.49, 3.71, 3.85 and 3.77 kg/s m-3) were significantly lower than those at the corresponding sites in control subjects (4.45, 4.66, 4.81 and 4.70 kg/s m-3). After the mouth opened, the tongue temperature decreased more rapidly in anaemia patients than in control subjects. To analyse the heat transfer mechanism, a transient heat transfer model of the tongue was developed. The tongue temperatures in anaemia patients and control subjects were calculated using this model and compared to the tongue temperatures measured by the IR thermal imager. The relationship between the tongue surface temperature and the tongue blood perfusion rate was analysed. The simulation results indicated that the low blood perfusion rate and the correlated changes in anaemia patients can cause faster temperature decreases of the tongue surface.

  6. Three-dimensional surface display with [sup 123]I-IMP brain perfusion imaging in patients with dementia

    Energy Technology Data Exchange (ETDEWEB)

    Tomino, Yoshio; Tachibana, Hisao; Sugita, Minoru [Hyogo Coll. of Medicine, Nishinomiya (Japan)

    1994-04-01

    We reconstructed three-dimensional (3D) surface images from SPECT data with N-isopropyl-p [[sup 123]I]-iodo-amphetamine ([sup 123]I-IMP) in 27 patients with Parkinson's disease (group 1), 16 patients with Alzheimer's disease (group 2), 9 patients with Binswanger's disease (group 3), and 11 elderly normal subjects (control group). Three-D reconstruction was performed using distance-shaded method at the threshold levels at intervals of 5% from 45% to 80%. In the control group, no perfusion defects were found in any region at threshold values below 60%, although the frontal and temporal cortices occasionally showed perfusion defects at threshold levels from 60% to 80%. In the group 1 of patients with dementia, perfusion defects were diffuse, particularly in the parietal and temporal cortices even at a threshold of 45%. The group 2 also showed diffuse perfusion defects, particularly in parietal and temporal cortices even at threshold levels as low as 45%. The primary visual cortex was less affected in this group. The demented patients in the group 1 demonstrated perfusion defects similar to those of patients in the group 2, although perfusion defects were more prominent in the group 2. In the group 3, patchy perfusion defects were found most frequently in the frontal region. Perfusion defects in the cerebellum and sensory motor cortex were more frequent in the group 3 than the other two groups, as well as the control group. The demented patients in the group 1 showed perfusion defects in the temporal and parietal cortices and demonstrated a perfusion pattern similar to those in the group 2. The patterns of brain perfusion in the group 3 were obviously different from those in the other two groups. In conclusion, 3D surface display of brain perfusion imaging may be useful for evaluating the cortical hypoperfusion regions in patients with dementia. It may also be of value in the differential diagnosis of cognitive disorders. (J.P.N.).

  7. Quantitative 4D Transcatheter Intraarterial Perfusion MR Imaging as a Method to Standardize Angiographic Chemoembolization Endpoints

    Science.gov (United States)

    Jin, Brian; Wang, Dingxin; Lewandowski, Robert J.; Ryu, Robert K.; Sato, Kent T.; Larson, Andrew C.; Salem, Riad; Omary, Reed A.

    2011-01-01

    PURPOSE We aimed to test the hypothesis that subjective angiographic endpoints during transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC) exhibit consistency and correlate with objective intraprocedural reductions in tumor perfusion as determined by quantitative four dimensional (4D) transcatheter intraarterial perfusion (TRIP) magnetic resonance (MR) imaging. MATERIALS AND METHODS This prospective study was approved by the institutional review board. Eighteen consecutive patients underwent TACE in a combined MR/interventional radiology (MR-IR) suite. Three board-certified interventional radiologists independently graded the angiographic endpoint of each procedure based on a previously described subjective angiographic chemoembolization endpoint (SACE) scale. A consensus SACE rating was established for each patient. Patients underwent quantitative 4D TRIP-MR imaging immediately before and after TACE, from which mean whole tumor perfusion (Fρ) was calculated. Consistency of SACE ratings between observers was evaluated using the intraclass correlation coefficient (ICC). The relationship between SACE ratings and intraprocedural TRIP-MR imaging perfusion changes was evaluated using Spearman’s rank correlation coefficient. RESULTS The SACE rating scale demonstrated very good consistency among all observers (ICC = 0.80). The consensus SACE rating was significantly correlated with both absolute (r = 0.54, P = 0.022) and percent (r = 0.85, P SACE rating scale demonstrates very good consistency between raters, and significantly correlates with objectively measured intraprocedural perfusion reductions during TACE. These results support the use of the SACE scale as a standardized alternative method to quantitative 4D TRIP-MR imaging to classify patients based on embolic endpoints of TACE. PMID:22021520

  8. Application of dual-energy scanning technique with dual-source CT in pulmonary mass lesions

    International Nuclear Information System (INIS)

    Jiang Jie; Xu Yiming; He Bo; Xie Xiaojie; Han Dan

    2012-01-01

    Objective: To explore the feasibility of DSCT dual-energy technique in pulmonary mass lesions. Methods: A total of 100 patients with pulmonary masses underwent conventional plain CT scan and dual-energy enhanced CT scan. The virtual non-contrast (VNC) images were obtained at post-processing workstation.The mean CT value,enhancement value,signal to noise ratio (SNR), image quality and radiation dose of pulmonary masses were compared between the two scan techniques using F or t test and the detectability of lesions was compared using Wilcoxon test. Results: There was no statistically significant difference among VNC (A) (32.89 ± 12.58) HU,VNC (S) (30.86 ± 9.60) HU and conventional plain images (35.89 ± 9.99) HU in mean CT value of mass (F =2.08, P>0.05). There was statistically significant difference among VNC (A) (3.29 ± 1.45), VNC (S) (3.93 ± 1.49) and conventional plain image (4.61 ± 1.50) in SNR (F =6.01, P<0.05), which of conventional plain scan was higher than that of VNC.The enhancement value of mass in conventional enhanced scan (60.74 ± 13.9) HU and distribution of iodine from VNC (A) (58.26 ± 31.99) HU was no statistically significant difference (t=0.48, P>0.05), but there was a significant difference between conventional enhanced scan (56.51 ± 17.94) HU and distribution of iodine from VNC (S) (52.65 ± 16.78) HU (t=4.45, P<0.05). There was no statistically significant difference among conventional plain scan (4.69 ± 0.06) and VNC (A) (4.60 ± 0.09), VNC (S) (4.61 ±0.11) in image quality at mediastinal window (F=3.014, P>0.05). The appearance, size, internal features of mass (such as necrosis, calcification and cavity) were showed the same in conventional plain scan, VNC (A) and VNC (S). Of 41 patients with hilar mass, 18 patients were found to have lobular and segmental perfusion decrease or defect. Perfusion defect area was found in 59 patients with peripheral lung mass. The radiation dose of dual-energy enhanced scan was lower than that of

  9. Localization and quantification of acute myocardial infarction by myocardial perfusion tomographic imaging

    International Nuclear Information System (INIS)

    Lin Xiufang; Min Changgeng; Lin Zhihu; Ke Ruoyi

    1994-01-01

    The authors reported the result of the quantification and localization of 30 clinically confirmed acute myocardial infarction patients in comparison with that of ECG. A left ventricle model was used to correct the area calculated by the method of Bull's eye. The result indicated that the infarction area calculated by the corrected Bull's eye method correlated closely with that determined by the ECG QRS scoring method (r = 0.706, P<0.01). Myocardial infarctions of all 30 patients were detected by both ECG and myocardial perfusion tomographic imaging. The accuracy of localization of myocardial infarction by myocardial perfusion imaging was similar to that of ECG in the anterior wall, anterior septum, anterior lateral and inferior wall, but superior to that of ECG in the apex, posterior lateral, posterior septum, and posterior wall

  10. Quantitative perfusion modeling in cardiac in-vivo nuclear magnetic resonance (NMR) imaging

    International Nuclear Information System (INIS)

    Carme, Sabin Charles

    2004-01-01

    A parametrical analysis of contrast agent distribution is proposed to interpret first pass MR images and to quantify the myocardial perfusion. We are concerned with the correction of spatial intensity variations in images. Furthermore, we are interested in the application of a robust NMR signal processing technique and deconvolution techniques adapted to low signal-to-noise ratio. Data sets were provided, close to clinical conditions, using in-vivo experiments applying several pharmacological stresses on ischemic pigs presenting a stenosis of the left circumflex coronary artery. The agreement and accuracy measurements between observers are respectively 57.1% and 53.1% for visual analysis, and 81.2% and 81.1% for parametric map analysis. A linear relationship between perfusion parameters and radioactive microspheres is established for low blood flows [fr

  11. Perfusion magnetic resonance imaging in pediatric brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Dallery, F.; Michel, D.; Constans, J.M.; Gondry-Jouet, C. [University Hospital, Department of Radiology, Amiens (France); Bouzerar, R.; Promelle, V.; Baledent, O. [University Hospital, Department of Imaging and Biophysics, Amiens (France); Attencourt, C. [University Hospital, Departement of Pathology, Amiens (France); Peltier, J. [University Hospital, Departement of Neurosurgery, Amiens (France)

    2017-11-15

    The use of DSC-MR imaging in pediatric neuroradiology is gradually growing. However, the number of studies listed in the literature remains limited. We propose to assess the perfusion and permeability parameters in pediatric brain tumor grading. Thirty children with a brain tumor having benefited from a DSC-MR perfusion sequence have been retrospectively explored. Relative CBF and CBV were computed on the ROI with the largest lesion coverage. Assessment of the lesion's permeability was also performed through the semi-quantitative PSR parameter and the K2 model-based parameter on the whole-lesion ROI and a reduced ROI drawn on the permeability maps. A statistical comparison of high- and low-grade groups (HG, LG) as well as a ROC analysis was performed on the histogram-based parameters. Our results showed a statistically significant difference between LG and HG groups for mean rCBV (p < 10{sup -3}), rCBF (p < 10{sup -3}), and for PSR (p = 0.03) but not for the K2 factor (p = 0.5). However, the ratio K2/PSR was shown to be a strong discriminating factor between the two groups of lesions (p < 10{sup -3}). For rCBV and rCBF indicators, high values of ROC AUC were obtained (> 0.9) and mean value thresholds were observed at 1.07 and 1.03, respectively. For K2/PSR in the reduced area, AUC was also superior to 0.9. The implementation of a dynamic T2* perfusion sequence provided reliable results using an objective whole-lesion ROI. Perfusion parameters as well as a new permeability indicator could efficiently discriminate high-grade from low-grade lesions in the pediatric population. (orig.)

  12. Characterization of Japanese standards for myocardial sympathetic and metabolic imaging in comparison with perfusion imaging

    International Nuclear Information System (INIS)

    Matsuo, Shinro; Nakajima, Kenichi; Okuda, Koichi; Yamashina, Shohei; Sakata, Kazuyuki; Momose, Mitsuru; Hashimoto, Jun; Kumita, Shinichiro; Kawano, Masaya

    2009-01-01

    The standard patterns of myocardial radiotracer distribution of 123 I-metaiodobenzylguanidine (MIBG) and 123 I-β-methyl-p-iodophenyl-pentadecanoic acid (BMIPP) should be defined in a Japanese population. The purpose of this study was to present and provide data on the characteristics of MIBG and BMIPP with respect to myocardial single photon emission computed tomography. The normal database included 123 I-MIBG and 123 I-BMIPP imaging and a 99 mTc-sestamibi/tetrofosmin myocardial perfusion study. The projection images were transferred by digital imaging and communications in medicine (DICOM) format and reconstructed and analyzed with polar maps. The projection data from multiple centers were successfully transferred to a common format for single photon emission computed tomography (SPECT) reconstruction. When the average values were analyzed using a 17-segment model, MIBG uptake in the inferior and apical wall appeared to be slightly lower than anterior uptake (P 99m Tc-tracer uptake (P<0.05). Myocardial sympathetic nerve and metabolic scintigraphy data that were specific for the Japanese population were generated and found to be different from that of perfusion tracers. The normal database can serve as a standard for nuclear cardiology work conducted in Japan. (author)

  13. Radiographic and radionuclide lung perfusion imaging in healthy calves and calves naturally infected with bovine respiratory syncytial virus

    International Nuclear Information System (INIS)

    Verhoeff, J.; Brom, W.E. van den; Ingh, T.S.G.A.M. van den

    1992-01-01

    Nine calves between three and 18 weeks old with serologically confirmed natural bovine respiratory syncytial virus infection were examined clinically, radiographically and by radionuclide lung perfusion imaging. The results were compared with those from seven healthy calves. The diseased calves were euthanased and examined pathologically, virologically and bacteriologically. The clinical signs indicated that the disease was in an acute stage. Radiography of the diseased animals revealed cysts, corresponding morphologically with bullous emphysema, and infiltrations roughly corresponding in distribution with atelectatic and, or, pneumonic areas. Radionuclide lung perfusion imaging revealed no perfusion shifts between the left and right lungs and a normal perfusion pattern in five of the nine diseased calves. The abnormalities in the perfusion patterns of three calves were probably caused by anatomical disorders such as cysts and pleural adhesions, but no cause of the abnormality could be found in one calf. These findings suggest that in calves infected with bovine respiratory syncytial virus, the normal perfusion pattern is maintained until anatomical disorders occur. The pathological examination and radiography revealed that the cranioventral lung fields were particularly poorly ventilated. This finding and the normal perfusion pattern indicate that these parts of the lungs are probably the sites where shuntings and perfusion-ventilation mismatchings occur

  14. Feasibility of ASL spinal bone marrow perfusion imaging with optimized inversion time.

    Science.gov (United States)

    Xing, Dong; Zha, Yunfei; Yan, Liyong; Wang, Kejun; Gong, Wei; Lin, Hui

    2015-11-01

    To assess the correlation between flow-sensitive alternating inversion recovery (FAIR) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in the measurement of spinal bone marrow (SBM) perfusion; in addition, to assess for an optimized inversion time (TI) as well as the reproducibility of SBM FAIR perfusion. The optimized TI of a FAIR SBM perfusion experiment was carried out on 14 volunteers; two adjacent vertebral bodies were selected from each volunteer to measure the change of signal intensity (ΔM) and the signal-to-noise ratio (SNR) of FAIR perfusion MRI with five different TIs. Then, reproducibility of FAIR data from 10 volunteers was assessed by the reposition SBM FAIR experiments. Finally, FAIR and DCE-MRI were performed on 27 subjects. The correlation between the blood flow on FAIR (BFASL ) and perfusion-related parameters on DCE-MRI was evaluated. The maximum value of ΔM and SNR were 36.39 ± 12.53 and 2.38 ± 0.97, respectively; both were obtained when TI was near 1200 msec. There were no significant difference between the two successive measurements of SBM BFASL perfusion (P = 0.879), and the within-subject coefficients of variation (wCV) of the measurements was 3.28%. The BFASL showed a close correlation with K(trans) (P FAIR perfusion scan protocol has good reproducibility, and as blood flow measurement on FAIR is reliable and closely related with the parameters on DCE-MRI, FAIR is feasible for measuring SBM blood flow. © 2015 Wiley Periodicals, Inc.

  15. Muscle perfusion and metabolic heterogeneity: insights from noninvasive imaging techniques

    DEFF Research Database (Denmark)

    Kalliokoski, Kari K; Scheede-Bergdahl, Celena; Kjaer, Michael

    2006-01-01

    Recent developments in noninvasive imaging techniques have enabled the study of local changes in perfusion and metabolism in skeletal muscle as well as patterns of heterogeneity in these variables in humans. In this review, the principles of these techniques along with some recent findings...... on functional heterogeneity in human skeletal muscle will be presented....

  16. Peritumoral brain edema in intracranial tumor evaluated by CT perfusion imaging

    International Nuclear Information System (INIS)

    Shi Yuxin; Xu Jianfeng

    2005-01-01

    Objective: To semi-quantitatively evaluate the cerebral perfusion in the peritumoral brain edema of cerebral tumors using CT perfusion imaging. Methods: Twenty-one patients with peritumoral brain edema (including pathologically confirmed meningiomas n=4, metastasis n=10, gliomas n=7) were examined by CT perfusion imaging. The regional cerebral blood flow (rCBF), regional cerebral blood volume (rCBV), and mean transit time (MTT) were calculated for peritumoral brain edema and the contralateralwhite matter. The rCBF and rCBV were compared between peritumoral brain edema and the contralateral white matter. The mean ratios (edema/contralateral white matter) of rCBF and rCBV were compared among the three tumors. Results: The rCBF and rCBV of peritumoral brain edema were significantly lower than those of contralateral white matter in patients with meningiomas and metastasis (rCBF: t=2.92 and 3.82, P 0.05). The mean ratios (edema/contralateralwhite matter) of rCBF and rCBV were not significantly different between meningiomas and metastasis (t=0.23 and 0.73, P>0.05), but both of them were significantly lower than those of gliomas (t=3.05 and 3.37, P<0.01, 0.005). Conclusion: The rCBF and rCBV in peritumoral brain edema were significantly lower than those of contralateral white matter in patients with meningiomas and metastasis, while almost the same with or higher than those of contralateral white matter in patients with gliomas. CT perfusion can provide quantitative information of blood flow in peritumoral brain edema, and is useful in the diagnosis and follow-up of cerebral tumors. (authors)

  17. Diagnosing acute pulmonary embolism with computed tomography: imaging update.

    Science.gov (United States)

    Devaraj, Anand; Sayer, Charlie; Sheard, Sarah; Grubnic, Sisa; Nair, Arjun; Vlahos, Ioannis

    2015-05-01

    Acute pulmonary embolism is recognized as a difficult diagnosis to make. It is potentially fatal if undiagnosed, yet increasing referral rates for imaging and falling diagnostic yields are topics which have attracted much attention. For patients in the emergency department with suspected pulmonary embolism, computed tomography pulmonary angiography (CTPA) is the test of choice for most physicians, and hence radiology has a key role to play in the patient pathway. This review will outline key aspects of the recent literature regarding the following issues: patient selection for imaging, the optimization of CTPA image quality and dose, preferred pathways for pregnant patients and other subgroups, and the role of CTPA beyond diagnosis. The role of newer techniques such as dual-energy CT and single-photon emission-CT will also be discussed.

  18. MR perfusion/diffusion-weighted imaging of acute ischemia in an animal model with PET correlation

    International Nuclear Information System (INIS)

    Pickens, D.R.; Dawson, R.C.; Votaw, J.R.; Lorenz, C.H.; Holburn, G.E.; Price, R.R.

    1990-01-01

    This paper evaluates acute cerebral ischemia in an animal model with MR perfusion/diffusion-sensitive pulse sequences and to compare the results with PET regional cerebral blood flow (rCBF) measurements. An embolizing agent was injected into the proximal middle cerebral artery (MCA) of a dog, and this was followed by DSA. Next, the animal was imaged in a 1.5-T MR system with perfusion/diffusion-sensitive spin-echo pulse sequence. Then, PET imaging was performed with H 2 O 15 at corresponding levels of the brain

  19. A Short Period of Ventilation without Perfusion Seems to Reduce Atelectasis without Harming the Lungs during Ex Vivo Lung Perfusion

    Directory of Open Access Journals (Sweden)

    Sandra Lindstedt

    2013-01-01

    Full Text Available To evaluate the lung function of donors after circulatory deaths (DCDs, ex vivo lung perfusion (EVLP has been shown to be a valuable method. We present modified EVLP where lung atelectasis is removed, while the lung perfusion is temporarily shut down. Twelve pigs were randomized into two groups: modified EVLP and conventional EVLP. When the lungs had reached 37°C in the EVLP circuit, lung perfusion was temporarily shut down in the modified EVLP group, and positive end-expiratory pressure (PEEP was increased to 10 cm H2O for 10 minutes. In the conventional EVLP group, PEEP was increased to 10 cm H2O for 10 minutes with unchanged lung perfusion. In the modified EVLP group, the arterial oxygen partial pressure (PaO2 was 18.5 ± 7.0 kPa before and 64.5 ± 6.0 kPa after the maneuver (P<0.001. In the conventional EVLP group, the PaO2 was 16.8 ± 3.1 kPa and 46.8 ± 2.7 kPa after the maneuver (P<0.01; P<0.01. In the modified EVLP group, the pulmonary graft weight was unchanged, while in the conventional EVLP group, the pulmonary graft weight was significantly increased. Modified EVLP with normoventilation of the lungs without ongoing lung perfusion for 10 minutes may eliminate atelectasis almost completely without harming the lungs.

  20. Quantitative Myocardial Perfusion Imaging Versus Visual Analysis in Diagnosing Myocardial Ischemia: A CE-MARC Substudy.

    Science.gov (United States)

    Biglands, John D; Ibraheem, Montasir; Magee, Derek R; Radjenovic, Aleksandra; Plein, Sven; Greenwood, John P

    2018-05-01

    This study sought to compare the diagnostic accuracy of visual and quantitative analyses of myocardial perfusion cardiovascular magnetic resonance against a reference standard of quantitative coronary angiography. Visual analysis of perfusion cardiovascular magnetic resonance studies for assessing myocardial perfusion has been shown to have high diagnostic accuracy for coronary artery disease. However, only a few small studies have assessed the diagnostic accuracy of quantitative myocardial perfusion. This retrospective study included 128 patients randomly selected from the CE-MARC (Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease) study population such that the distribution of risk factors and disease status was proportionate to the full population. Visual analysis results of cardiovascular magnetic resonance perfusion images, by consensus of 2 expert readers, were taken from the original study reports. Quantitative myocardial blood flow estimates were obtained using Fermi-constrained deconvolution. The reference standard for myocardial ischemia was a quantitative coronary x-ray angiogram stenosis severity of ≥70% diameter in any coronary artery of >2 mm diameter, or ≥50% in the left main stem. Diagnostic performance was calculated using receiver-operating characteristic curve analysis. The area under the curve for visual analysis was 0.88 (95% confidence interval: 0.81 to 0.95) with a sensitivity of 81.0% (95% confidence interval: 69.1% to 92.8%) and specificity of 86.0% (95% confidence interval: 78.7% to 93.4%). For quantitative stress myocardial blood flow the area under the curve was 0.89 (95% confidence interval: 0.83 to 0.96) with a sensitivity of 87.5% (95% confidence interval: 77.3% to 97.7%) and specificity of 84.5% (95% confidence interval: 76.8% to 92.3%). There was no statistically significant difference between the diagnostic performance of quantitative and visual analyses (p = 0.72). Incorporating rest myocardial