WorldWideScience

Sample records for ptw program modules

  1. Effect of Filler Content on the Performance of Epoxy/PTW Composites

    Directory of Open Access Journals (Sweden)

    Mudradi Sudheer

    2014-01-01

    Full Text Available This paper presents the mechanical and tribological characteristics of potassium titanate whisker (PTW reinforced epoxy composites. The effect of various test variables and material parameters on the friction and wear behavior of epoxy/PTW composites has been studied systematically. Tribological tests were conducted on a pin-on-disc apparatus under dry sliding conditions. Addition of PTW was found to improve the wear resistance of the composites and 15 wt% PTW filled epoxy exhibited lowest specific wear rate and highest friction coefficient compared to other test samples. PTW additions showed beneficiary effect on density, hardness, and stiffness properties of composites; however, strength properties and ductility were found to decrease with the increasing content of PTW. Scanning electron microscope (SEM images of tensile fractured surfaces and worn-out surfaces of selected samples revealed different fracture mechanisms.

  2. Analytic EoS and PTW strength model recommendation for Starck Ta

    Energy Technology Data Exchange (ETDEWEB)

    Sjue, Sky K. [Los Alamos National Laboratory; Prime, Michael Bruce [Los Alamos National Laboratory

    2016-09-01

    The purpose of this document is to provide an analytic EoS and PTW strength model for Starck Ta that can be consistently used between different platforms and simulations at three labs. This should provide a consistent basis for comparison of the results of calculations, but not the best implementation for matching a wide variety of experimental data. Another version using SESAME tables should follow, which will provide a better physical representation over a broader range of conditions. The data sets available at the time only include one Hopkinson bar at a strain rate of 1800/s; a broader range of high-rate calibration data would be preferred. The resulting fit gives the PTW parameter p = 0. To avoid numerical issues, p = 0:001 has been used in FLAG. The PTW parameters that apply above the maximum strain rate in the data use the values from the original publication.

  3. Quality control of portal imaging with PTW EPID QC PHANTOM registered

    International Nuclear Information System (INIS)

    Pesznyak, Csilla; Kiraly, Reka; Polgar, Istvan; Zarand, Pal; Mayer, Arpad; Fekete, Gabor; Mozes, Arpad; Kiss, Balazs

    2009-01-01

    Purpose: quality assurance (QA) and quality control (QC) of different electronic portal imaging devices (EPID) and portal images with the PTW EPID QC PHANTOM registered . Material and methods: characteristic properties of images of different file formats were measured on Siemens OptiVue500aSi registered , Siemens BeamView Plus registered , Elekta iView registered , and Varian PortalVision trademark and analyzed with the epidSoft registered 2.0 program in four radiation therapy centers. The portal images were taken with Kodak X-OMAT V registered and the Kodak Portal Localisation ReadyPack registered films and evaluated with the same program. Results: the optimal exposition both for EPIDs and portal films of different kind was determined. For double exposition, the 2+1 MU values can be recommended in the case of Siemens OptiVue500aSi registered , Elekta iView registered and Kodak Portal Localisation ReadyPack registered films, while for Siemens BeamView Plus registered , Varian PortalVision trademark and Kodak X-OMAT V registered film 7+7 MU is recommended. Conclusion: the PTW EPID QC PHANTOM registered can be used not only for amorphous silicon EPIDs but also for images taken with a video-based system or by using an ionization chamber matrix or for portal film. For analysis of QC tests, a standardized format (used at the acceptance test) should be applied, as the results are dependent on the file format used. (orig.)

  4. Quality control test solutions for diagnostic radiology, nuclear medicine and health physics with PTW equipment

    International Nuclear Information System (INIS)

    Froescher, Olga

    2007-01-01

    Complete test of publication follows. In 1922 PTW-Freiburg was founded to produce and market a revolutionary new electromechanical component for measuring very small electrical charges. Today PTW is the specialist and one of the global market leaders for manufacturing and supplying high-quality products in diagnostic radiology, nuclear medicine, radiation therapy and health physics. The quality control of X-ray images is influenced by a number of parameters. To maintain a consistent performance of X-ray installations, quality checks have to be conducted regularly. PTW offers a variety of diagnostic test tools for different X-ray devices, and therefore to reduce patient exposure and costs for X-ray departments. PTW's 'Code of Practice' defines in an easy and compact way how to perform quality control measurements on different diagnostic X-ray installations. The necessary equipment for measuring main parameters as well as acceptable limits are mentioned accordingly. The 'Code of Practice' bases on actual standards.

  5. Quality control of portal imaging with PTW EPID QC PHANTOM {sup registered}

    Energy Technology Data Exchange (ETDEWEB)

    Pesznyak, Csilla; Kiraly, Reka; Polgar, Istvan; Zarand, Pal; Mayer, Arpad [Inst. of Oncoradiology, Uzsoki Hospital, Budapest (Hungary); Fekete, Gabor [Dept. of Oncotherapy, Univ. of Szeged (Hungary); Mozes, Arpad [Oncology Center, Kalman Pandy County Hospital, Gyula (Hungary); Kiss, Balazs [Dept. of Radiation Oncology, Markusovszky County Hospital, Szombathely (Hungary)

    2009-01-15

    Purpose: quality assurance (QA) and quality control (QC) of different electronic portal imaging devices (EPID) and portal images with the PTW EPID QC PHANTOM {sup registered}. Material and methods: characteristic properties of images of different file formats were measured on Siemens OptiVue500aSi {sup registered}, Siemens BeamView Plus {sup registered}, Elekta iView {sup registered}, and Varian PortalVision trademark and analyzed with the epidSoft {sup registered} 2.0 program in four radiation therapy centers. The portal images were taken with Kodak X-OMAT V {sup registered} and the Kodak Portal Localisation ReadyPack {sup registered} films and evaluated with the same program. Results: the optimal exposition both for EPIDs and portal films of different kind was determined. For double exposition, the 2+1 MU values can be recommended in the case of Siemens OptiVue500aSi {sup registered}, Elekta iView {sup registered} and Kodak Portal Localisation ReadyPack {sup registered} films, while for Siemens BeamView Plus {sup registered}, Varian PortalVision trademark and Kodak X-OMAT V {sup registered} film 7+7 MU is recommended. Conclusion: the PTW EPID QC PHANTOM {sup registered} can be used not only for amorphous silicon EPIDs but also for images taken with a video-based system or by using an ionization chamber matrix or for portal film. For analysis of QC tests, a standardized format (used at the acceptance test) should be applied, as the results are dependent on the file format used. (orig.)

  6. Evaluation of an autonomous braking system in real-world PTW crashes.

    Science.gov (United States)

    Savino, Giovanni; Pierini, Marco; Rizzi, Matteo; Frampton, Richard

    2013-01-01

    Powered 2-wheelers (PTWs) are becoming increasingly popular in Europe. They have the ability to get around traffic queues, thus lowering fuel consumption and increasing mobility. The risk of rider injury in a traffic crash is however much higher than that associated with car users. The European project, Powered Two Wheeler Integrated Safety (PISa), identified an autonomous braking system (AB) as a priority to reduce the injury consequences of a PTW crash. The aim of this study was to assess the potential effectiveness of the AB system developed in PISa, taking into account the specific system characteristics that emerged during the design, development and testing phases. Fifty-eight PTW cases representing European crash configurations were examined, in which 43 percent of riders sustained a Maximum Abbreviated Injury Scale (MAIS) 2+ injury. Two of the most common crash types were a PTW impacting a stationary object (car following scenario) 16% and an object pulling across the PTW path (crossing scenario) 54%. An expert team analysed the in-depth material of the sample crashes and determined a posteriori to what extent the AB would have affected the crash. For those cases where the AB was evaluated as applicable, a further quantitative evaluation of the benefits was conducted by considering a set of different possible rider reactions in addition to that exhibited in the actual crash. In 67 percent of cases, the application of AB could have mitigated the crash outcome. Analysis of those real crash cases showed the potential for an expert rider to avoid the collision. An early reaction of the rider, associated with a correct application of the brakes would have avoided 18 of the 37 car following/crossing scenarios. Conversely, according to the analysis, an expert rider would not have been able to avoid 19 of the 37 cases. In 14 of those 19 cases, the AB would have contributed to mitigating the crash outcome. This study demonstrated significant potential for

  7. Program analysis and presentation of results of the profiles and depth dose rates obtained with the PTW software MC{sub 2} MEPHYSTO; Programa de analisis y presentacion de resultados de los perfiles y porcentajes de dosis en profundidad adquiridos con el software MEPHYSTO MC2 de PTW

    Energy Technology Data Exchange (ETDEWEB)

    Tato de la Cuevas, F.

    2011-07-01

    In the periodic quality control of linear accelerators is usually included acquisition and analysis of profiles and PDDs (percentage depth dose). In the protocol of Quality Control of electron accelerators for clinical use of the proposed analysis SEFM 4 Profiles for each of the energies used clinically. This involves a large number of curves to be analyzed and the subsequent introduction of the parameters in a spreadsheet or similar for your assessment as to the reference state. We have developed a program that analyzes the curves acquired by mcc Mephysto PTW software and presents the results of that analysis in a spreadsheet.

  8. Technology and Changing Lifestyles. Teacher's Guide. Preparing for Tomorrow's World.

    Science.gov (United States)

    Iozzi, Louis A.

    "Technology and Changing Lifestyles" is one of the "Preparing for Tomorrow's World" (PTW) program modules. PTW is an interdisciplinary, future-oriented program incorporating information from the sciences and social sciences and addressing societal concerns which interface science/technology/society. The program promotes…

  9. Determination of recombination and polarity correction factors, kS and kP, for small cylindrical ionization chambers PTW 31021 and PTW 31022 in pulsed filtered and unfiltered beams.

    Science.gov (United States)

    Bruggmoser, Gregor; Saum, Rainer; Kranzer, Rafael

    2018-01-12

    The aim of this technical communication is to provide correction factors for recombination and polarity effect for two new ionization chambers PTW PinPoint 3D (type 31022) and PTW Semiflex 3D (type 31021). The correction factors provided are for the (based on the) German DIN 6800-2 dosimetry protocol and the AAPM TG51 protocol. The measurements were made in filtered and unfiltered high-energy photon beams in a water equivalent phantom at maximum depth of the PDD and a field size on the surface of 10cm×10cm. The design of the new chamber types leads to an ion collection efficiency and a polarity effect that are well within the specifications requested by pertinent dosimetry protocols including the addendum of TG-51. It was confirmed that the recombination effect of both chambers mainly depends on dose per pulse and is independent of the filtration of the photon beam. Copyright © 2018. Published by Elsevier GmbH.

  10. Dosimetric characterization of the PTW Seven29 dosimeter and Octavius Phantom for IMRT quality control; Caracterizacao dosimetrica do dosimetro PTW Seven29 e Octavius Phantom para controle de qualidade em IMRT

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Leandro R.; Habitzreuter, Angela B.; Santos, Gabriela R.; Watanabe, Erica Y.; Silva, Marco A.; Menegussi, Gisela; Rodrigues, Laura N.; Furnari, Laura, E-mail: leandrorg11@hotmail.com [Instituto do Cacer do Estado de Sao Paulo (ICESP), SP (Brazil). Servico de Radioterapia

    2012-12-15

    Techniques like IMRT, VMAT and tomotherapy has been used to improve dose conformity in the target, while sparing adjacent normal tissues. The complexity of this techniques challenge to correctly verify the dose delivery, in an independent way. Matrix detectors have been used for this purpose. Although, to exactly understand the dosimeter response and to identify his limitations, characterization measurements need to be performed. These dosimeters, for instance, can present angular dependence. Phantoms has been designed to, when used together the detector, eliminate this angular dependence. The aim of this work was to characterize PTW Seven 29 dosimeter and also his use with Octavius Phantom (PTW). The dosimeter showed reproducible with 0.25% the biggest standard deviation, good dose linearity and dose rate independence. Differences for output factors were obtained (<6%), but a clinical case measurement showed that the set can be used for IMRT verification. When used with Octavius Phantom the dosimeter showed low angular dependence. (author)

  11. Analysis of the stability of PTW riders in autonomous braking scenarios.

    Science.gov (United States)

    Symeonidis, Ioannis; Kavadarli, Gueven; Erich, Schuller; Graw, Matthias; Peldschus, Steffen

    2012-11-01

    While fatalities of car occupants in the EU decreased remarkably over the last decade, Powered Two Wheelers (PTWs) fatalities still increase following the increase of PTW ownership. Autonomous braking systems have been implemented in several types of vehicles and are presently addressed by research in the field of PTWs. A major concern in this context is the rider stability. Experiments with volunteers were performed in order to find out whether autonomous braking for PTWs will produce a greater instability of the rider in comparison to manual braking. The PTW's braking conditions were simulated in a laboratory with a motorcycle mock-up mounted on a sled, which was accelerated with an average of 0.35 g. The motion of the rider was captured in autonomous braking scenarios with and without pre-warning as well as in manual braking scenarios. No significant differences between the scenarios were found with respect to maximum forward displacement of the volunteer's torso and head (pautonomous braking at low deceleration will not cause significant instabilities of the rider in comparison to manual braking in idealized laboratory conditions. Based on this, further research into the development and implementation of autonomous braking systems for PTWs, e.g. by extensive riding tests, seems valuable. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Starck Ta PTW strength model recommendation for use with SESAME 93524 EoS

    Energy Technology Data Exchange (ETDEWEB)

    Sjue, Sky K. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Prime, Michael Bruce [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-02-27

    The purpose of this document is to provide a calibration of the Preston-Tonks- Wallace (PTW) strength model for use with the new SESAME equation of state (EoS) 93524. The calibration data included in this t spans temperatures from 198 K to 673 K and strain rates from 0.001/s to 3200/s.

  13. Dosimetric characterization of the PTW Seven29 dosimeter and Octavius Phantom for IMRT quality control

    International Nuclear Information System (INIS)

    Goncalves, Leandro R.; Habitzreuter, Angela B.; Santos, Gabriela R.; Watanabe, Erica Y.; Silva, Marco A.; Menegussi, Gisela; Rodrigues, Laura N.; Furnari, Laura

    2012-01-01

    Techniques like IMRT, VMAT and tomotherapy has been used to improve dose conformity in the target, while sparing adjacent normal tissues. The complexity of this techniques challenge to correctly verify the dose delivery, in an independent way. Matrix detectors have been used for this purpose. Although, to exactly understand the dosimeter response and to identify his limitations, characterization measurements need to be performed. These dosimeters, for instance, can present angular dependence. Phantoms has been designed to, when used together the detector, eliminate this angular dependence. The aim of this work was to characterize PTW Seven 29 dosimeter and also his use with Octavius Phantom (PTW). The dosimeter showed reproducible with 0.25% the biggest standard deviation, good dose linearity and dose rate independence. Differences for output factors were obtained (<6%), but a clinical case measurement showed that the set can be used for IMRT verification. When used with Octavius Phantom the dosimeter showed low angular dependence. (author)

  14. Monitoring Linear Accelerator Output Constancy Using the PTW Linacheck

    International Nuclear Information System (INIS)

    McDermott, Garry M.; Buckle, Andrew H.

    2011-01-01

    The PTW-Linacheck was assessed for its ability to monitor linear accelerator radiation output constancy. The key issues that were considered were the setup for daily output measurements, e.g., requirements for build-up and backscatter material, and the reproducibility and linearity of the device with linear accelerator output. An appropriate measurement setup includes a 10 x 10 cm field at 100 cm FSD, 5 cm backscatter, and no added build-up for 4 MeV electron beams, 1 cm added build-up for 6-16 MeV electron beams and 5 cm added build-up for 6-15 MV photon beams. Using this measurement setup, the dose linearity and short-term reproducibility were acceptable; however, the Linacheck should be recalibrated on a monthly basis to ensure acceptable long-term reproducibility.

  15. Extract of Polygala tenuifolia Alleviates Stress-Exacerbated Atopy-Like Skin Dermatitis through the Modulation of Protein Kinase A and p38 Mitogen-Activated Protein Kinase Signaling Pathway

    Directory of Open Access Journals (Sweden)

    Bongjun Sur

    2017-01-01

    Full Text Available Atopic dermatitis (AD and stress create a vicious cycle: stress exacerbates atopic symptoms, and atopic disease elicits stress and anxiety. Targeting multiple pathways including stress and allergic inflammation is, therefore, important for treating AD. In this study, we investigated the remedial value of Polygala tenuifolia Willd. (PTW for treating immobilization (IMO stress-exacerbated atopy-like skin dermatitis and its underlying mechanism. Trimellitic anhydride (TMA was applied to dorsal skin for sensitization and subsequently both ears for eliciting T-cell-dependent contact hypersensitivity in mice, which underwent 2 h-IMO stress and PTW administration for the latter 6 and 9 days in the ear exposure period of TMA, respectively. To elicit in vitro degranulation of human mast cell line-1 (HMC-1, 10 µM substance P (SP and 200 nM corticotrophin-releasing factor (CRF were sequentially added with 48 h-interval. PTW extract (500 µg/mL was added 30 min before CRF treatment. IMO stress exacerbated TMA-induced scratching behavior by 252%, and increased their blood corticosterone levels by two-fold. Treatment with 250 mg/kg PTW significantly restored IMO stress-exacerbated scratching behavior and other indicators such as skin inflammation and water content, lymph node weights, and serum histamine and immunoglobulin E (lgE levels. Furthermore, it also reversed TMA-stimulated expression of tumor necrosis factor (TNF-α and interleukin (IL-4 mRNAs in ear tissues. PTW significantly inhibited SP/CRF-stimulated degranulation of HMC-1 cells, subsequent tryptase secretion, and protein kinase A (PKA activity. PTW also selectively inhibited p38 mitogen-activated protein kinase (MAPK phosphorylation in SP/CRF-treated HMC-1 cells. PTW significantly inhibited HMC-1 cell degranulation and alleviated IMO stress-exacerbated atopic dermatitis symptoms by modulating the PKA/p38 MAPK signaling pathway.

  16. OSHA Training Programs. Module SH-48. Safety and Health.

    Science.gov (United States)

    Center for Occupational Research and Development, Inc., Waco, TX.

    This student module on OSHA (Occupational Safety and Health Act) training programs is one of 50 modules concerned with job safety and health. This module provides a list of OSHA training requirements and describes OSHA training programs and other safety organizations' programs. Following the introduction, 11 objectives (each keyed to a page in the…

  17. Assessment of MicroDiamond PTW 60019 detector and its comparison with other detectors for relative dosimetry in small radiosurgery fields of the Leksell gamma knife perfexion

    International Nuclear Information System (INIS)

    Novotny, J. Jr.; Kozubikova, P.; Pastykova, V.; Pipek, J.; Bhatnagar, J. P.; Huq, M. S.; Veselsky, T.

    2014-01-01

    Measurement of relative output factors (ROF) for the Leksell Gamma Knife (LGK) is not a trivial task due to strict demands of an accurate set up and small size of measured radiosurgery fields. The purpose of this study was to perform an assessment of a new synthetic single crystal MicroDiamond PTW 60019 detector (volume 0.004 mm 3 ) for measurement of ROFs for 4 mm and 8 mm collimators for the LGK Perfexion. Small sensitive volume of this detector, near water equivalence and low energy dependence make it an attractive candidate for small field dosimetry. Results obtained in this study were compared with results measured by broad variety of different detectors and also Monte Carlo (MC) simulation. MicroDiamond detector connected to PTW UNIDOS electrometer was positioned in ELEKTA spherical phantom and pre-irradiated to dose of 5 Gy. Measurements were performed in two different detector positions: 1) parallel with table axis, 2) orthogonal to table axis. Electrometer timer of 1 min was used to measure subsequently signal from 16 mm, 8 mm and 4 mm beams. Altogether ten measurements were performed for each of three collimator sizes. Results from MicroDiamond were compared with those obtained from various types of detectors used in the past by authors for measurement of LGK ROFs. New synthetic single crystal MicroDiamond PTW 60019 detector appears to be a very promising detector for relative output factor measurements in very small radiosurgery fields. (authors)

  18. Is the PTW 60019 microDiamond a suitable candidate for small field reference dosimetry?

    Science.gov (United States)

    De Coste, Vanessa; Francescon, Paolo; Marinelli, Marco; Masi, Laura; Paganini, Lucia; Pimpinella, Maria; Prestopino, Giuseppe; Russo, Serenella; Stravato, Antonella; Verona, Claudio; Verona-Rinati, Gianluca

    2017-09-01

    A systematic study of the PTW microDiamond (MD) output factors (OF) is reported, aimed at clarifying its response in small fields and investigating its suitability for small field reference dosimetry. Ten MDs were calibrated under 60Co irradiation. OF measurements were performed in 6 MV photon beams by a CyberKnife M6, a Varian DHX and an Elekta Synergy linacs. Two PTW silicon diodes E (Si-D) were used for comparison. The results obtained by the MDs were evaluated in terms of absorbed dose to water determination in reference conditions and OF measurements, and compared to the results reported in the recent literature. To this purpose, the Monte Carlo (MC) beam-quality correction factor, kQMD , was calculated for the MD, and the small field output correction factors, k{{Qclin},{{Q}msr}}{{fclin},{{f}msr}} , were calculated for both the MD and the Si-D by two different research groups. An empirical function was also derived, providing output correction factors within 0.5% from the MC values calculated for all of the three linacs. A high reproducibility of the dosimetric properties was observed among the ten MDs. The experimental kQMD values are in agreement within 1% with the MC calculated ones. Output correction factors within  +0.7% and  -1.4% were obtained down to field sizes as narrow as 5 mm. The resulting MD and Si-D field factors are in agreement within 0.2% in the case of CyberKnife measurements and 1.6% in the other cases. This latter higher spread of the data was demonstrated to be due to a lower reproducibility of small beam sizes defined by jaws or multi leaf collimators. The results of the present study demonstrate the reproducibility of the MD response and provide a validation of the MC modelling of this device. In principle, accurate reference dosimetry is thus feasible by using the microDiamond dosimeter for field sizes down to 5 mm.

  19. Programming Programmable Logic Controller. High-Technology Training Module.

    Science.gov (United States)

    Lipsky, Kevin

    This training module on programming programmable logic controllers (PLC) is part of the memory structure and programming unit used in a packaging systems equipment control course. In the course, students assemble, install, maintain, and repair industrial machinery used in industry. The module contains description, objectives, content outline,…

  20. Overview of the TFTB lithium blanket module program

    International Nuclear Information System (INIS)

    Jassby, D.L.

    1986-01-01

    The Lithium Blanket Module (LBM) is an ∼ 80-cm 3 module, representative of a helium-cooled lithium oxide fusion reactor blanket module. This paper summarizes the design, development, and construction of the LBM, and indicates the present status of the LBM program

  1. Performance of a PTW 60019 microDiamond detector in a 1.5 T MRI-linac

    Science.gov (United States)

    Woodings, S. J.; Wolthaus, J. W. H.; van Asselen, B.; de Vries, J. H. W.; Kok, J. G. M.; Lagendijk, J. J. W.; Raaymakers, B. W.

    2018-03-01

    Accurate small-field dosimetry is critical for a magnetic resonance linac (MRI-linac). The PTW 60019 microDiamond is close to an ideal detector for small field dosimetry due to its small physical size, high signal-to-noise ratio and approximate water equivalence. It is important to fully characterise the performance of the detector in a 1.5 T magnetic field prior to its use for MRI-linac commissioning and quality assurance. Standard techniques of detector testing have been implemented, or adapted where necessary to suit the capabilities of the MRI-linac. Detector warmup, constancy, dose linearity, dose rate linearity, field size dependence and leakage were within tolerance. Measurements with the detector were consistent with ion chamber measurements for medium sized fields. The effective point of measurement of the detector when used within a 1.5 T magnetic field was determined to be 0.80 ± 0.23 mm below the top surface of the device, consistent with the existing vendor recommendation and alignment mark at 1.0 mm. The angular dependence was assessed. Variations of up to 9.7% were observed, which are significantly greater than in a 0 T environment. Within the expected range of use, the maximum effect is approximately 0.6% which is within tolerance. However for large beams within a magnetic field, the divergence and consequent variation in angle of photon incidence means that the microDiamond would not be ideal for characterising the profiles and it would not be suitable for determining large-field beam parameters such as symmetry. It would also require a correction factor prior to use for patient-specific QA measurements where radiation is delivered from different gantry angles. The results of this study demonstrate that the PTW 60019 microDiamond detector is suitable for measuring small radiation fields within a 1.5 T magnetic field and thus is suitable for use in MRI-linac commissioning and quality assurance.

  2. Overview of the TFTR Lithium Blanket Module program

    International Nuclear Information System (INIS)

    Jassby, D.L.

    1986-01-01

    The LBM (Lithium Blanket Module) is an approximately cubic module, about 80 cm on each side, with construction representative of a helium-cooled lithium oxide fusion reactor blanket module. Measurements of neutron transport and tritium breeding in the LBM will be made in irradiation programs first with a point-neutron source, and subsequently with the D-D and D-T fusion-neutron sources of the TFTR. This paper summarizes the objectives of the LBM program, the design, development and construction of the LBM, and progress in the experimental tests

  3. Report on the SCT Forward Electrical Module Program

    CERN Document Server

    Benes, J; Feld, L; Hornung, M; Joos, D; Ketterer, C; Kodys, P; Kubik, P; Ludwig, J; Modesto, P; Rieth, G; Runge, K; Smith, T; Snow, S W; Taylor, G; Webel, M

    1999-01-01

    IN THE CONTEXT OF THE ATLAS SCT FORWARD HYBRID PROGRAM, THREEELECTRICAL DETECTOR MODULES HAVE BEEN BUILT. THIS NOTE DESCRIBES THEASSEMBLY AND SUMMARISES THE MECHANICAL AND ELECTRICAL PROPERTIES OFTHESE MODULES. SOME COMMENTS ON THE SPECIAL REQUIREMENTS OF THEPRODUCTION OF A REAL MODULE AS COMPARED TO DUMMY MODULES ARE GIVEN.A LIST OF OPEN QUESTIONS ARISING FROM THIS ASSEMBLY RUN IS APPENDED.

  4. Affirmative Action. Module Number 16. Work Experience Program Modules. Coordination Techniques Series.

    Science.gov (United States)

    Shawhan, Carl; Morley, Ray

    This self-instructional module, the last in a series of 16 on techniques for coordinating work experience programs, deals with affirmative action. Addressed in the module are the following topics: the nature of affirmative action legislation and regulations, the role of the teacher-coordinator as a resource person for affirmative action…

  5. Quality control of specific patient in radiotherapy with modulated intensity

    International Nuclear Information System (INIS)

    Aberbuj, P D; Tapia Coca, R C

    2012-01-01

    In this work we comment the details of the patient specific quality controls of the first Intensity Modulated Radiotherapy treatment done at Roffo Institute. These controls consisted in two sets of measurements: absolute dose with ionization chamber and relative dose with two dosimetric systems (Gafchromic EBT2 radiochromic films and the PTW 729 ionization chambers array). Two of the filters did not pass the dosimetrical tests, and they were manufactured again. The new filters passed the tests. For the relative two-dimensional measurements the radiochromic films had a better performance than the array due to their higher spatial resolution (author)

  6. Experimental determination of the PTW 60019 microDiamond dosimeter active area and volume

    Energy Technology Data Exchange (ETDEWEB)

    Marinelli, Marco, E-mail: marco.marinelli@uniroma2.it; Prestopino, G.; Verona, C.; Verona-Rinati, G. [INFN–Dipartimento di Ingegneria Industriale, Università di Roma “Tor Vergata,” Via del Politecnico 1, Roma 00133 (Italy)

    2016-09-15

    Purpose: Small field output correction factors have been studied by several research groups for the PTW 60019 microDiamond (MD) dosimeter, by comparing the response of such a device with both reference dosimeters and Monte Carlo simulations. A general good agreement is observed for field sizes down to about 1 cm. However, evident inconsistencies can be noticed when comparing some experimental results and Monte Carlo simulations obtained for smaller irradiation fields. This issue was tentatively attributed by some authors to unintentional large variations of the MD active surface area. The aim of the present study is a nondestructive experimental determination of the MD active surface area and active volume. Methods: Ten MD dosimeters, one MD prototype, and three synthetic diamond samples were investigated in the present work. 2D maps of the MD response were recorded under scanned soft x-ray microbeam irradiation, leading to an experimental determination of the device active surface area. Profiles of the device responses were measured as well. In order to evaluate the MD active volume, the thickness of the diamond sensing layer was independently evaluated by capacitance measurements and alpha particle detection experiments. The MD sensitivity, measured at the PTW calibration laboratory, was also used to calculate the device active volume thickness. Results: An average active surface area diameter of (2.19 ± 0.02) mm was evaluated by 2D maps and response profiles of all the MDs. Average active volume thicknesses of (1.01 ± 0.13) μm and (0.97 ± 0.14) μm were derived by capacitance and sensitivity measurements, respectively. The obtained results are well in agreement with the nominal values reported in the manufacturer dosimeter specifications. A homogeneous response was observed over the whole device active area. Besides the one from the device active volume, no contributions from other components of the housing nor from encapsulation materials were observed in

  7. Method for Statically Checking an Object-oriented Computer Program Module

    Science.gov (United States)

    Bierhoff, Kevin M. (Inventor); Aldrich, Jonathan (Inventor)

    2012-01-01

    A method for statically checking an object-oriented computer program module includes the step of identifying objects within a computer program module, at least one of the objects having a plurality of references thereto, possibly from multiple clients. A discipline of permissions is imposed on the objects identified within the computer program module. The permissions enable tracking, from among a discrete set of changeable states, a subset of states each object might be in. A determination is made regarding whether the imposed permissions are violated by a potential reference to any of the identified objects. The results of the determination are output to a user.

  8. Implementation of the Air Program Information Management System (APIMS) Inspection Module

    Science.gov (United States)

    2009-05-01

    7 5 T H A I R B A S E W I N G Implementation of the Air Program Information Management System (APIMS) Inspection Module 2009 Environment...Implementation of the Air Program Information Management System (APIMS) Inspection Module 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER

  9. Fast logic modules with programmed functions

    International Nuclear Information System (INIS)

    Zinov, V.G.; Selikov, A.V.

    1987-01-01

    Modern nuclear-physical experiment procedure requires automated control and adjustment of event selection and recording systems. Nanosecond programmed-control units realizing optional set of combinational logic functions are described. Programmed permanent storage device is the basis of one unit, and on-line storage device, preliminary provided with truth tables, is in the basis of the other units. The resolution time is 40 ns. By means of auxiliary unit the programmed logic devices with sequent storage elements (digital timer and pulse generator; multiple-phase generator; sequential digital controller) are realized. The units are performed in CAMAC standard, the modules size being 1M

  10. Universal geometrical module for MARS program

    International Nuclear Information System (INIS)

    Talanov, V.V.

    1992-01-01

    Geometrical program module for modeling hadron and electromagnetic cascades, which accomplishes comparison of physical coordinates with the particle current state of one of the auxilliary cells, is described. The whole medium wherein the particles are tracked, is divided into a certain number of auxilliary cells. The identification algorithm of the cell, through which the particle trajectory passes, is considered in detail. The described algorithm for cell identification was developed for the MARS program and realized in form of a set of subprograms written in the FORTRAN language. 4 refs., 1 tab

  11. The MARX Modulator Development Program for the International Linear Collider

    International Nuclear Information System (INIS)

    Leyh, G.E.

    2006-01-01

    The International Linear Collider (ILC) Marx Modulator Development Program at SLAC is working towards developing a full-scale ILC Marx ''Reference Design'' modulator prototype, with the goal of significantly reducing the size and cost of the ILC modulator while improving overall modulator efficiency and availability. The ILC Reference Design prototype will provide a proof-of-concept model to industry in advance of Phase II SBIR funding, and also allow operation of the new 10MW L-Band Klystron prototypes immediately upon their arrival at SLAC

  12. The Program Module of Information Risk Numerical Estimation

    Directory of Open Access Journals (Sweden)

    E. S. Stepanova

    2011-03-01

    Full Text Available The algorithm of information risks analysis realized in the program module on the basis of threats matrixes and fuzzy cognitive maps describing potential threats on resources is offered in this paper.

  13. Bilingual Skills Training Program. Barbering/Cosmetology. Module 7.0: Endocrine System.

    Science.gov (United States)

    Northern New Mexico Community Coll., El Rito.

    This module on the endocrine system is the seventh of ten (CE 028 308-318) in the barbering/cosmetology course of a bilingual skills training program. (A Vocabulary Development Workbook for modules 6-10 is available as CE 028 313.) The course is designed to furnish theoretical and laboratory epxerience. Module objectives are for students to…

  14. Bilingual Skills Training Program. Barbering/Cosmetology. Module 4.0: Skeletal System.

    Science.gov (United States)

    Northern New Mexico Community Coll., El Rito.

    This module on the skeletal system is the fourth of ten (CE 028 308-318) in the barbering/cosmetology course of a bilingual skill training program. (A Vocabulary Development Workbook for modules 6-10 is available as CE 028 313.) The course is designed to furnish theoretical and laboratory experience. Module objectives are for students to develop…

  15. Bilingual Skills Training Program. Barbering/Cosmetology. Module 6.0: Muscular System.

    Science.gov (United States)

    Northern New Mexico Community Coll., El Rito.

    This module on the muscular system is the sixth of ten (CE 028 308-318) in the barbering/cosmetology course of a bilingual skills training program. (A Vocabulary Development Workbook for modules 6-10 is available as CE 028 313.) The course is designed to furnish theoretical and laboratory experience. Module objectives are for students to develop…

  16. Brief Video-Module Administered Mindfulness Program for Physicians: A Pilot Study.

    Science.gov (United States)

    Pflugeisen, Bethann Mangel; Drummond, Dike; Ebersole, Drew; Mundell, Kate; Chen, David

    2016-01-01

    The purpose of this study was to evaluate the feasibility of implementing a video-module-based mindfulness pilot program intended to reduce stress, improve well-being, and develop mindfulness skills in physicians in a community hospital setting. Preliminary findings are presented. Using a single-sample, pre-post study design, we administered an eight-week mindfulness training offered as part of a wellness initiative for medical staff in a suburban community hospital. Participants enrolled on a first-come, first-served basis. Participants engaged in three 90-min in-person trainings, weekly online video-module trainings, and weekly teleconference coaching calls. Video-module trainings were available at all times, to be accessed at the participants׳ convenience. Journals and a guided meditation audio library were also provided. Physician stress, well-being (emotional exhaustion, depersonalization of patients, and sense of personal accomplishment), and mindfulness skills (observing, describing, acting with awareness, and accepting without judgment) were evaluated at baseline, end-of-program, and eight weeks post-intervention using well-validated instruments. A total of 23 physicians enrolled and 19 completed the program. Compared to baseline, statistically significant decreases in stress, personal accomplishment, and emotional exhaustion were observed at end-of-program and eight weeks post-intervention (all P < .05). Significant increases in all mindfulness skills were observed at end-of-program; these increases persisted for describing, acting with awareness, and accepting without judgment at eight weeks post-intervention (all P < .05). This study provides preliminary evidence that a flexible, video-module-based mindfulness program can decrease stress, increase well-being, and develop lasting mindfulness skills in physicians. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. The TFTR lithium blanket module program

    International Nuclear Information System (INIS)

    Jassby, D.L.; Bertone, P.C.; Creedon, R.L.; File, J.; Graumann, D.W.

    1985-01-01

    The Lithium Blanket Module (LBM) is an approximately 80X80X80 cm cubic module, representative of a helium-cooled lithium oxide fusion reactor blanket module, that will be installed on the TFTR (Tokamak Fusion Test Reactor) in late 1986. The principal objective of the LBM Program is to perform a series of neutron transport and tritium-breeding measurements throughout the LBM when it is exposed to the TFTR toroidal fusion neutron source, and to compare these data with the predictions of Monte Carlo (MCNP) neutronics codes. The LBM consists of 920 2.5-cm diameter breeder rods constructed of lithium oxide (Li 2 O) pellets housed in thin-walled stainless steel tubes. Procedures for mass-producing 25,000 Li 2 O pellets with satisfactory reproducibility were developed using purified Li 2 O powder, and fabrication of all the breeder rods was completed in early 1985. Tritium assay methods were investigated experimentally using both small lithium metal samples and LBM-type pellets. This work demonstrated that the thermal extraction method will be satisfactory for accurate evaluation of the minute concentrations of tritium expected in the LBM pellets (0.1-1nCi/g)

  18. Neutron dosimetry for the TFTR Lithium-Blanket-Module program

    International Nuclear Information System (INIS)

    Harker, Y.D.; Tsang, F.Y.; Caffrey, A.J.; Homeyer, W.G.; Engholm, B.A.

    1981-01-01

    The Tokamak Fusion Test Reactor (TFTR) Lithium Blanket Module (LBM) program is a first-of-a-kind neutronics experiment involving a prototypical fusion reactor blanket module with a distributed neutron source from the plasma of the TFTR at Princeton Plasma Physics Laboratory. The objectives of the LBM program are: (1) to test the capabilities of neutron transport codes when applied to fusion test reactor blanket conditions, and (2) to obtain tritium breeding performance data on a typical design concept of a fusion-reactor blanket. This paper addresses the issues relative to the measurement of neutron fields in the LBM, presents the results of preliminary design studies concerning neutron measurements and also presents the results of blanket mockup experiments performed at the Idaho National Engineering Laboratory

  19. PVSIM{copyright}: A simulation program for photovoltaic cells, modules, and arrays

    Energy Technology Data Exchange (ETDEWEB)

    King, D.L.; Dudley, J.K.; Boyson, W.E.

    1996-06-01

    An electrical simulation model for photovoltaic cells, modules, and arrays has been developed that will be useful to a wide range of analysts in the photovoltaic industry. The Microsoft{reg_sign} Windows{trademark} based program can be used to analyze individual cells, to analyze the effects of cell mismatch or reverse bias(`hot spot`) heating in modules and to analyze the performance of large arrays of modules including bypass and blocking diodes. User defined statistical variance can be applied to the fundamental parameters used to simulate the cells and diodes. The model is most appropriate for cells that can be accurately modeled using a two-diode equivalent circuit. This paper describes the simulation program and illustrates its versatility with examples.

  20. RANCANG BANGUN SISTEM E-LEARNING PEMROGRAMAN PADA MODUL DETEKSI PLAGIARISME KODE PROGRAM DAN STUDENT FEEDBACK SYSTEM

    Directory of Open Access Journals (Sweden)

    Abdul Munif

    2017-01-01

    Full Text Available Kompetensi utama yang harus dimiliki oleh mahasiswa jurusan ilmu komputer/informatika adalah pemrograman. Perkuliahan yang berbasis pemrograman seringkali mewajibkan mahasiswa untuk mengerjakan soal yang cukup banyak. Hal ini tentunya akan menyulitkan dosen dalam mengevaluasi hasil pekerjaan mahasiswa. Selain itu, dimungkinkan pula adanya praktik mahasiswa yang memplagiat hasil dari mahasiswa lain. Penelitian ini bertujuan untuk menjawab permasalahan tersebut. Pada penelitian ini dikembangkan sebuah sistem pembelajaran/e-learning pemrograman. Modul sistem e-learning yang dibuat pada artikel ini terbatas pada modul deteksi kemiripan kode program dan student feedback system. Modul deteksi kemiripan kode program berfungsi untuk mengecek kemiripan kode program antar mahasiswa. Kemudian kode-kode program yang memiliki tingkat kemiripan tinggi akan dikelompokkan menjadi satu menggunakan algoritma hierarchical clustering. Proses pengecekan kemiripan program dimulai dari proses transformasi kode program ke dalam Abstract Syntax Tree (AST, kemudian ditransformasi menjadi sequence dan dihitung kemiripannya menggunakan algoritma Levenshtein Distance. Modul student feedback system berfungsi untuk mengecek kemiripan kode program mahasiswa dengan dosen. Mahasiswa akan mendapatkan informasi apakah kode program mereka sudah sesuai dengan yang diinginkan oleh dosen atau belum. Sebelum sistem memberikan umpan balik, terlebih dahulu kode program dosen dan mahasiswa diproses menjadi AST dan kemudian menjadi sequence. Sistem akan membandingkan kemiripan kode program dosen dan mahasiswa menggunakan algoritma Smith-Waterman yang telah dimodifikasi. Kemudian sistem menampilkan baris-baris kode mana saja yang sama antara kode program dosen dengan kode program mahasiswa. Dari hasil pengujian dapat disimpulkan bahwa modul deteksi plagiarisme dan student feedback system telah terimplementasi dengan baik.

  1. CONTRIBUTION OF A LINEAR PROGRAMMING VBA MODULE TO STUDENTS PEFORMANCE

    Directory of Open Access Journals (Sweden)

    KUČÍRKOVÁ Lenka

    2010-12-01

    Full Text Available This paper deals with the application of freeware modules as a teaching support of Operations Research methods at the Department of Systems Engineering, Czech university of Life Sciences (CULS Prague. In particular, we concentrated on a linear programming module and measured the impact on student performance. The motivation for this evaluation is based on a current development of a new module that focuses on Traveling Salesman Problem. First, we explain the current situation both worldwide and in the Czech Republic and the CULS Prague. Subsequently, we describe the content of students’ exams and statistical methods applied to the evaluation. Finally, we analyze and generalize the obtained results. The students exams have show a positive impact of the modules. Further, our analysis has proven that this impact is statistically significant. The findings motivate us to made new modules for other methods.

  2. GRUKON - A package of applied computer programs system input and operating procedures of functional modules

    International Nuclear Information System (INIS)

    Sinitsa, V.V.; Rineiskij, A.A.

    1993-04-01

    This manual describes a software package for the production of multigroup neutron cross-sections from evaluated nuclear data files. It presents the information necessary for the implementation of the program's modules in the framework of the execution of the program, including: operating procedures of the program, the data input, the macrocommand language, the assignment of the system's procedures. This report also presents the methodology used in the coding of the individual modules: the rules, the syntax, the method of procedures. The report also presents an example of the application of the data processing module. (author)

  3. Frequency modulation television analysis: Threshold impulse analysis. [with computer program

    Science.gov (United States)

    Hodge, W. H.

    1973-01-01

    A computer program is developed to calculate the FM threshold impulse rates as a function of the carrier-to-noise ratio for a specified FM system. The system parameters and a vector of 1024 integers, representing the probability density of the modulating voltage, are required as input parameters. The computer program is utilized to calculate threshold impulse rates for twenty-four sets of measured probability data supplied by NASA and for sinusoidal and Gaussian modulating waveforms. As a result of the analysis several conclusions are drawn: (1) The use of preemphasis in an FM television system improves the threshold by reducing the impulse rate. (2) Sinusoidal modulation produces a total impulse rate which is a practical upper bound for the impulse rates of TV signals providing the same peak deviations. (3) As the moment of the FM spectrum about the center frequency of the predetection filter increases, the impulse rate tends to increase. (4) A spectrum having an expected frequency above (below) the center frequency of the predetection filter produces a higher negative (positive) than positive (negative) impulse rate.

  4. LOFT fuel modules design, characterization, and fabrication program

    International Nuclear Information System (INIS)

    Russell, M.L.

    1977-06-01

    The loss-of-fluid test [LOFT) fuel modules have evolved from a comprehensive five-year design, characterization, and fabrication program which has resulted in the accomplishment of many technical activities of interest in pressurized water reactor fuel design development and safety research. Information is presented concerning: determination of fundamental high-temperature reactor material properties; design invention related to in-core instrumentation attachment; implementation of advanced and/or unique fuel bundle characterization techniques; implementation of improved fuel bundle fabrication techniques; and planning and execution of a multimillion dollar design, characterization, and fabrication program for pressurized water reactor fuel

  5. Software requirements specification for the program analysis and control system risk management module

    International Nuclear Information System (INIS)

    SCHAEFER, J.C.

    1999-01-01

    TWR Program Analysis and Control System Risk Module is used to facilitate specific data processes surrounding the Risk Management program of the Tank Waste Retrieval environment. This document contains the Risk Management system requirements of the database system

  6. Development of user interface to support automatic program generation of nuclear power plant analysis by module-based simulation system

    International Nuclear Information System (INIS)

    Yoshikawa, Hidekazu; Mizutani, Naoki; Nakaya, Ken-ichiro; Wakabayashi, Jiro

    1988-01-01

    Module-based Simulation System (MSS) has been developed to realize a new software work environment enabling versatile dynamic simulation of a complex nuclear power system flexibly. The MSS makes full use of modern software technology to replace a large fraction of human software works in complex, large-scale program development by computer automation. Fundamental methods utilized in MSS and developmental study on human interface system SESS-1 to help users in generating integrated simulation programs automatically are summarized as follows: (1) To enhance usability and 'communality' of program resources, the basic mathematical models of common usage in nuclear power plant analysis are programed as 'modules' and stored in a module library. The information on usage of individual modules are stored in module database with easy registration, update and retrieval by the interactive management system. (2) Target simulation programs and the input/output files are automatically generated with simple block-wise languages by a precompiler system for module integration purpose. (3) Working time for program development and analysis in an example study of an LMFBR plant thermal-hydraulic transient analysis was demonstrated to be remarkably shortened, with the introduction of an interface system SESS-1 developed as an automatic program generation environment. (author)

  7. Star Power: Providing for the Gifted & Talented. Module 9. Programs for the Gifted/Talented.

    Science.gov (United States)

    Mallis, Jackie; Heinemann, Alison

    The document presents Module 9, programs for the gifted/talented, of the Star Power modules developed for school personnel who have an interest in or a need to explore the area of gifted and talented education. It is explained in an introductory section that the modules can be used for independent study, for small group interaction, or for a large…

  8. Development of whole core thermal-hydraulic analysis program ACT. 3. Coupling core module with primary heat transport system module

    International Nuclear Information System (INIS)

    Ohtaka, Masahiko; Ohshima, Hiroyuki

    1998-10-01

    A whole core thermal-hydraulic analysis program ACT is being developed for the purpose of evaluating detailed in-core thermal hydraulic phenomena of fast reactors including inter-wrapper flow under various reactor operation conditions. In this work, the core module as a main part of the ACT developed last year, which simulates thermal-hydraulics in the subassemblies and the inter-subassembly gaps, was coupled with an one dimensional plant system thermal-hydraulic analysis code LEDHER to simulate transients in the primary heat transport system and to give appropriate boundary conditions to the core model. The effective algorithm to couple these two calculation modules was developed, which required minimum modification of them. In order to couple these two calculation modules on the computing system, parallel computing technique using PVM (Parallel Virtual Machine) programming environment was applied. The code system was applied to analyze an out-of-pile sodium experiment simulating core with 7 subassemblies under transient condition for code verification. It was confirmed that the analytical results show a similar tendency of experimental results. (author)

  9. The effectiveness of web-programming module based on scientific approach to train logical thinking ability for students in vocational high school

    Science.gov (United States)

    Nashiroh, Putri Khoirin; Kamdi, Waras; Elmunsyah, Hakkun

    2017-09-01

    Web programming is a basic subject in Computer and Informatics Engineering, a program study in a vocational high school. It requires logical thinking ability in its learning activities. The purposes of this research were (1) to develop a web programming module that implement scientific approach that can improve logical thinking ability for students in vocational high school; and (2) to test the effectiveness of web programming module based on scientific approach to train students' logical thinking ability. The results of this research was a web-programming module that apply scientific approach for learning activities to improve logical thinking ability of students in the vocational high school. The results of the effectiveness test of web-programming module give conclusion that it was very effective to train logical thinking ability and to improve learning result, this conclusion was supported by: (1) the average of posttest result of students exceeds the minimum criterion value, it was 79.91; (2) the average percentage of students' logical thinking score is 82,98; and (3) the average percentage of students' responses to the web programming module was 81.86%.

  10. CAMAC module control from the TPA-1001/i by means of the FOCAL programming language

    International Nuclear Information System (INIS)

    Angelov, A.Kh.; Dubovik, L.V.

    1977-01-01

    The possibility of using FOCAL programming language to control CAMAC modules by minicomputer is considered. This language allows to make effective changes in the program and reduce the time necessary for writing and running programmes. To address CAMAC modules a packet of CAMAC subroutines from the CAMAC-tr A/i software is included into FOCAL language, its operational possibilities and linguistic peculiarities being completely preserved. A big fast memory enables one to add three additional functions to the function list of FOCAL language. An example is given illustrating the use of these functions

  11. A Self-Instructional Course in Student Financial Aid Administration. Module 5: Title IV Institutional and Program Eligibility. Second Edition.

    Science.gov (United States)

    Washington Consulting Group, Inc., Washington, DC.

    The fifth module in a 17-module self-instructional course on student financial aid administration teaches novice student financial aid administrators and other personnel about Title IV institutional and program eligibility. This introduction to management of federal financial aid programs authorized by the Higher Education Act Title IV, discusses…

  12. Module-based Simulation System for efficient development of nuclear simulation programs

    International Nuclear Information System (INIS)

    Yoshikawa, Hidekazu; Wakabayashi, Jiro

    1990-01-01

    Module-based Simulation System (MSS) has been developed to realize a new software environment enabling versatile dynamic simulation of a complex nuclear power plant system flexibly. Described in the paper are (i) fundamental methods utilized in MMS and its software systemization, (ii) development of human interface system to help users in generating integrated simulation programs automatically, and (iii) development of an intelligent user support system for helping users in the two phases of automatical semantic diagnosis and consultation to automatic input data setup for the MSS-generated programs. (author)

  13. [Innovative Services: The Use of Parent Aides in Child Protective Services]. Module 2. Program Models--Which One is Right for You?

    Science.gov (United States)

    Anderson, Stephen C.; And Others

    Module 2 of a seven module package for child protective service workers explores various types of parent aide programs for abused and neglected children and their families. Four training activities address models of parent aide programs, organization analysis, and selection of the appropriate program model. Included are directions for using the…

  14. An introduction to NASA's advanced computing program: Integrated computing systems in advanced multichip modules

    Science.gov (United States)

    Fang, Wai-Chi; Alkalai, Leon

    1996-01-01

    Recent changes within NASA's space exploration program favor the design, implementation, and operation of low cost, lightweight, small and micro spacecraft with multiple launches per year. In order to meet the future needs of these missions with regard to the use of spacecraft microelectronics, NASA's advanced flight computing (AFC) program is currently considering industrial cooperation and advanced packaging architectures. In relation to this, the AFC program is reviewed, considering the design and implementation of NASA's AFC multichip module.

  15. Comparison between In-house developed and Diamond commercial software for patient specific independent monitor unit calculation and verification with heterogeneity corrections.

    Science.gov (United States)

    Kuppusamy, Vijayalakshmi; Nagarajan, Vivekanandan; Jeevanandam, Prakash; Murugan, Lavanya

    2016-02-01

    The study was aimed to compare two different monitor unit (MU) or dose verification software in volumetric modulated arc therapy (VMAT) using modified Clarkson's integration technique for 6 MV photons beams. In-house Excel Spreadsheet based monitor unit verification calculation (MUVC) program and PTW's DIAMOND secondary check software (SCS), version-6 were used as a secondary check to verify the monitor unit (MU) or dose calculated by treatment planning system (TPS). In this study 180 patients were grouped into 61 head and neck, 39 thorax and 80 pelvic sites. Verification plans are created using PTW OCTAVIUS-4D phantom and also measured using 729 detector chamber and array with isocentre as the suitable point of measurement for each field. In the analysis of 154 clinically approved VMAT plans with isocentre at a region above -350 HU, using heterogeneity corrections, In-house Spreadsheet based MUVC program and Diamond SCS showed good agreement TPS. The overall percentage average deviations for all sites were (-0.93% + 1.59%) and (1.37% + 2.72%) for In-house Excel Spreadsheet based MUVC program and Diamond SCS respectively. For 26 clinically approved VMAT plans with isocentre at a region below -350 HU showed higher variations for both In-house Spreadsheet based MUVC program and Diamond SCS. It can be concluded that for patient specific quality assurance (QA), the In-house Excel Spreadsheet based MUVC program and Diamond SCS can be used as a simple and fast accompanying to measurement based verification for plans with isocentre at a region above -350 HU. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  16. DEVELOPMENT OF PROGRAM MODULE FOR CALCULATING SPEED OF TITANIC PLASMA SEDIMENTATION IN ENVIRONMENT OF TECHNOLOGICAL GAS

    Directory of Open Access Journals (Sweden)

    S. A. Ivaschenko

    2006-01-01

    Full Text Available The program module has been developed on the basis of package of applied MATLAB programs which allows to calculate speed of coating sedimentation over the section of plasma stream taking into account magnetic field influence of a stabilizing coil, and also to correct the obtained value of sedimentation speed depending on the value of negative accelerating potential, arch current, technological gas pressure. The program resolves visualization of calculation results.

  17. Space Experiment Module (SEM)

    Science.gov (United States)

    Brodell, Charles L.

    1999-01-01

    The Space Experiment Module (SEM) Program is an education initiative sponsored by the National Aeronautics and Space Administration (NASA) Shuttle Small Payloads Project. The program provides nationwide educational access to space for Kindergarten through University level students. The SEM program focuses on the science of zero-gravity and microgravity. Within the program, NASA provides small containers or "modules" for students to fly experiments on the Space Shuttle. The experiments are created, designed, built, and implemented by students with teacher and/or mentor guidance. Student experiment modules are flown in a "carrier" which resides in the cargo bay of the Space Shuttle. The carrier supplies power to, and the means to control and collect data from each experiment.

  18. Air density dependence of the response of the PTW SourceCheck 4pi ionization chamber for 125I brachytherapy seeds.

    Science.gov (United States)

    Torres Del Río, J; Tornero-López, A M; Guirado, D; Pérez-Calatayud, J; Lallena, A M

    2017-06-01

    To analyze the air density dependence of the response of the new SourceCheck 4pi ionization chamber, manufactured by PTW. The air density dependence of three different SourceCheck 4pi chambers was studied by measuring 125 I sources. Measurements were taken by varying the pressure from 746.6 to 986.6hPa in a pressure chamber. Three different HDR 1000 Plus ionization chambers were also analyzed under similar conditions. A linear and a potential-like function of the air density were fitted to experimental data and their achievement in describing them was analyzed. SourceCheck 4pi chamber response showed a residual dependence on the air density once the standard pressure and temperature factor was applied. The chamber response was overestimated when the air density was below that under normal atmospheric conditions. A similar dependence was found for the HDR 1000 Plus chambers analyzed. A linear function of the air density permitted a very good description of this residual dependence, better than with a potential function. No significant variability between the different specimens of the same chamber model studied was found. The effect of overestimation observed in the chamber responses once they are corrected for the standard pressure and temperature may represent a non-negligible ∼4% overestimation in high altitude cities as ours (700m AMSL). This overestimation behaves linearly with the air density in all cases analyzed. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  19. SPICE Module for the Satellite Orbit Analysis Program (SOAP)

    Science.gov (United States)

    Coggi, John; Carnright, Robert; Hildebrand, Claude

    2008-01-01

    A SPICE module for the Satellite Orbit Analysis Program (SOAP) precisely represents complex motion and maneuvers in an interactive, 3D animated environment with support for user-defined quantitative outputs. (SPICE stands for Spacecraft, Planet, Instrument, Camera-matrix, and Events). This module enables the SOAP software to exploit NASA mission ephemeris represented in the JPL Ancillary Information Facility (NAIF) SPICE formats. Ephemeris types supported include position, velocity, and orientation for spacecraft and planetary bodies including the Sun, planets, natural satellites, comets, and asteroids. Entire missions can now be imported into SOAP for 3D visualization, playback, and analysis. The SOAP analysis and display features can now leverage detailed mission files to offer the analyst both a numerically correct and aesthetically pleasing combination of results that can be varied to study many hypothetical scenarios. The software provides a modeling and simulation environment that can encompass a broad variety of problems using orbital prediction. For example, ground coverage analysis, communications analysis, power and thermal analysis, and 3D visualization that provide the user with insight into complex geometric relations are included. The SOAP SPICE module allows distributed science and engineering teams to share common mission models of known pedigree, which greatly reduces duplication of effort and the potential for error. The use of the software spans all phases of the space system lifecycle, from the study of future concepts to operations and anomaly analysis. It allows SOAP software to correctly position and orient all of the principal bodies of the Solar System within a single simulation session along with multiple spacecraft trajectories and the orientation of mission payloads. In addition to the 3D visualization, the user can define numeric variables and x-y plots to quantitatively assess metrics of interest.

  20. SU-E-T-209: Independent Dose Calculation in FFF Modulated Fields with Pencil Beam Kernels Obtained by Deconvolution

    International Nuclear Information System (INIS)

    Azcona, J; Burguete, J

    2014-01-01

    Purpose: To obtain the pencil beam kernels that characterize a megavoltage photon beam generated in a FFF linac by experimental measurements, and to apply them for dose calculation in modulated fields. Methods: Several Kodak EDR2 radiographic films were irradiated with a 10 MV FFF photon beam from a Varian True Beam (Varian Medical Systems, Palo Alto, CA) linac, at the depths of 5, 10, 15, and 20cm in polystyrene (RW3 water equivalent phantom, PTW Freiburg, Germany). The irradiation field was a 50 mm diameter circular field, collimated with a lead block. Measured dose leads to the kernel characterization, assuming that the energy fluence exiting the linac head and further collimated is originated on a point source. The three-dimensional kernel was obtained by deconvolution at each depth using the Hankel transform. A correction on the low dose part of the kernel was performed to reproduce accurately the experimental output factors. The kernels were used to calculate modulated dose distributions in six modulated fields and compared through the gamma index to their absolute dose measured by film in the RW3 phantom. Results: The resulting kernels properly characterize the global beam penumbra. The output factor-based correction was carried out adding the amount of signal necessary to reproduce the experimental output factor in steps of 2mm, starting at a radius of 4mm. There the kernel signal was in all cases below 10% of its maximum value. With this correction, the number of points that pass the gamma index criteria (3%, 3mm) in the modulated fields for all cases are at least 99.6% of the total number of points. Conclusion: A system for independent dose calculations in modulated fields from FFF beams has been developed. Pencil beam kernels were obtained and their ability to accurately calculate dose in homogeneous media was demonstrated

  1. The Air Force Manufacturing Technology (MANTECH): Technology transfer methodology as exemplified by the radar transmit/receive module program

    Science.gov (United States)

    Houpt, Tracy; Ridgely, Margaret

    1991-01-01

    The Air Force Manufacturing Technology program is involved with the improvement of radar transmit/receive modules for use in active phased array radars for advanced fighter aircraft. Improvements in all areas of manufacture and test of these modules resulting in order of magnitude improvements in the cost of and the rate of production are addressed, as well as the ongoing transfer of this technology to the Navy.

  2. Gener: a minimal programming module for chemical controllers based on DNA strand displacement.

    Science.gov (United States)

    Kahramanoğulları, Ozan; Cardelli, Luca

    2015-09-01

    : Gener is a development module for programming chemical controllers based on DNA strand displacement. Gener is developed with the aim of providing a simple interface that minimizes the opportunities for programming errors: Gener allows the user to test the computations of the DNA programs based on a simple two-domain strand displacement algebra, the minimal available so far. The tool allows the user to perform stepwise computations with respect to the rules of the algebra as well as exhaustive search of the computation space with different options for exploration and visualization. Gener can be used in combination with existing tools, and in particular, its programs can be exported to Microsoft Research's DSD tool as well as to LaTeX. Gener is available for download at the Cosbi website at http://www.cosbi.eu/research/prototypes/gener as a windows executable that can be run on Mac OS X and Linux by using Mono. ozan@cosbi.eu. © The Author 2015. Published by Oxford University Press.

  3. A Self-Instructional Course in Student Financial Aid Administration. Module 17--Evaluation of Student Aid Management: Self-Evaluation, Audit, and Program Review. Second Edition.

    Science.gov (United States)

    Washington Consulting Group, Inc., Washington, DC.

    The 17th module in the 17-module self-instructional course on student financial aid administration discusses the evaluation of student aid management in terms of self-evaluation, audit, and program review. The full course offers a systematic introduction to the management of federal financial aid programs authorized by Title IV of the Higher…

  4. Comparison of Size Modulation Standard Automated Perimetry and Conventional Standard Automated Perimetry with a 10-2 Test Program in Glaucoma Patients.

    Science.gov (United States)

    Hirasawa, Kazunori; Takahashi, Natsumi; Satou, Tsukasa; Kasahara, Masayuki; Matsumura, Kazuhiro; Shoji, Nobuyuki

    2017-08-01

    This prospective observational study compared the performance of size modulation standard automated perimetry with the Octopus 600 10-2 test program, with stimulus size modulation during testing, based on stimulus intensity and conventional standard automated perimetry, with that of the Humphrey 10-2 test program in glaucoma patients. Eighty-seven eyes of 87 glaucoma patients underwent size modulation standard automated perimetry with Dynamic strategy and conventional standard automated perimetry using the SITA standard strategy. The main outcome measures were global indices, point-wise threshold, visual defect size and depth, reliability indices, and test duration; these were compared between size modulation standard automated perimetry and conventional standard automated perimetry. Global indices and point-wise threshold values between size modulation standard automated perimetry and conventional standard automated perimetry were moderately to strongly correlated (p 33.40, p modulation standard automated perimetry than with conventional standard automated perimetry, but the visual-field defect size was smaller (p modulation-standard automated perimetry than on conventional standard automated perimetry. The reliability indices, particularly the false-negative response, of size modulation standard automated perimetry were worse than those of conventional standard automated perimetry (p modulation standard automated perimetry than with conventional standard automated perimetry (p = 0.02). Global indices and the point-wise threshold value of the two testing modalities correlated well. However, the potential of a large stimulus presented at an area with a decreased sensitivity with size modulation standard automated perimetry could underestimate the actual threshold in the 10-2 test protocol, as compared with conventional standard automated perimetry.

  5. An Evaluative Study of an ICT Module for a School Leadership and Management Preparation Program

    Science.gov (United States)

    Musgrave, Sarietjie; De Wet, Corene

    2017-01-01

    This study reports on findings of an evaluative study on the effectiveness of an information and communication technology (ICT) module that forms part of the Advanced Certificate in Education: School Leadership and Management program. The study was carried out among distance education (DE) students from the University of the Free State enrolled…

  6. Color Developing Capacity of Plasma-treated Water as a Source of Nitrite for Meat Curing.

    Science.gov (United States)

    Jung, Samooel; Kim, Hyun Joo; Park, Sanghoo; Yong, Hae In; Choe, Jun Ho; Jeon, Hee-Joon; Choe, Wonho; Jo, Cheorun

    2015-01-01

    The interaction of plasma with liquid generates nitrogen species including nitrite (NO(-) 2). Therefore, the color developing capacity of plasma-treated water (PTW) as a nitrite source for meat curing was investigated in this study. PTW, which is generated by surface dielectric barrier discharge in air, and the increase of plasma treatment time resulted in increase of nitrite concentration in PTW. The PTW used in this study contains 46 ppm nitrite after plasma treatment for 30 min. To evaluate the effect of PTW on the cured meat color, meat batters were prepared under three different conditions (control, non-cured meat batter; PTW, meat batter cured with PTW; Sodium nitrite, meat batter cured with sodium nitrite). The meat batters were vacuum-packaged and cooked in a water-bath at 80℃ for 30 min. The typical color of cured meat developed in cooked meat batter treated with sodium nitrite or PTW. The lightness (L*) and yellowness (b*) values were similar in all conditions, whereas, the redness (a*) values of cooked meat batter with PTW and sodium nitrite (pnitrite source in the curing process of meat without addition of other nitrite sources.

  7. Biosphere 2 test module experimentation program

    Science.gov (United States)

    Alling, Abigail; Leigh, Linda S.; Maccallum, Taber; Alvarez-Romo, Norberto

    1990-01-01

    The Biosphere 2 Test Module is a facility which has the capability to do either short or long term closures: five month closures with plants were conducted. Also conducted were investigations of specific problems, such as trace gas purification by bioregenerative systems by in-putting a fixed concentration of a gas and observing its uptake over time. In other Test Module experiments, the concentration of one gas was changed to observe what effects this has on other gases present or on the system. The science of biospherics which encompasses the study of closed biological systems provides an opening into the future in space as well as in the Earth's biosphere.

  8. Modules based on the geochemical model PHREEQC for use in scripting and programming languages

    Science.gov (United States)

    Charlton, Scott R.; Parkhurst, David L.

    2011-01-01

    The geochemical model PHREEQC is capable of simulating a wide range of equilibrium reactions between water and minerals, ion exchangers, surface complexes, solid solutions, and gases. It also has a general kinetic formulation that allows modeling of nonequilibrium mineral dissolution and precipitation, microbial reactions, decomposition of organic compounds, and other kinetic reactions. To facilitate use of these reaction capabilities in scripting languages and other models, PHREEQC has been implemented in modules that easily interface with other software. A Microsoft COM (component object model) has been implemented, which allows PHREEQC to be used by any software that can interface with a COM server—for example, Excel®, Visual Basic®, Python, or MATLAB". PHREEQC has been converted to a C++ class, which can be included in programs written in C++. The class also has been compiled in libraries for Linux and Windows that allow PHREEQC to be called from C++, C, and Fortran. A limited set of methods implements the full reaction capabilities of PHREEQC for each module. Input methods use strings or files to define reaction calculations in exactly the same formats used by PHREEQC. Output methods provide a table of user-selected model results, such as concentrations, activities, saturation indices, and densities. The PHREEQC module can add geochemical reaction capabilities to surface-water, groundwater, and watershed transport models. It is possible to store and manipulate solution compositions and reaction information for many cells within the module. In addition, the object-oriented nature of the PHREEQC modules simplifies implementation of parallel processing for reactive-transport models. The PHREEQC COM module may be used in scripting languages to fit parameters; to plot PHREEQC results for field, laboratory, or theoretical investigations; or to develop new models that include simple or complex geochemical calculations.

  9. Steps in Modular Specifications for Concurrent Modules

    DEFF Research Database (Denmark)

    Da Rocha Pinto, Pedro; Dinsdale-Young, Thomas; Gardner, Philippa

    2015-01-01

    The specification of a concurrent program module is a difficult problem. The specifications must be strong enough to enable reasoning about the intended clients without reference to the underlying module implementation. We survey a range of verification techniques for specifying concurrent module......, in particular highlighting four key concepts: auxiliary state, interference abstraction, resource ownership and atomicity. We show how these concepts combine to provide powerful approaches to specifying concurrent modules.......The specification of a concurrent program module is a difficult problem. The specifications must be strong enough to enable reasoning about the intended clients without reference to the underlying module implementation. We survey a range of verification techniques for specifying concurrent modules...

  10. The Endocrine System [and] Instructor's Guide: The Endocrine System. Health Occupations Education Module: Instructional Materials in Anatomy and Physiology for Pennsylvania Health Occupations Programs.

    Science.gov (United States)

    National Evaluation Systems, Inc., Amherst, MA.

    This module on the endocrine system is one of 17 modules designed for individualized instruction in health occupations education programs at both the secondary and postsecondary levels. It is part of an eight-unit miniseries on anatomy and physiology within the series of 17 modules. Following a preface which explains to the student how to use the…

  11. AN EVALUATIVE STUDY OF AN ICT MODULE FOR A SCHOOL LEADERSHIP AND MANAGEMENT PREPARATION PROGRAM

    Directory of Open Access Journals (Sweden)

    Sarietjie MUSGRAVE

    2017-04-01

    Full Text Available This study reports on findings of an evaluative study on the effectiveness of an information and communication technology (ICT module that forms part of the Advanced Certificate in Education: School Leadership and Management program. The study was carried out among distance education (DE students from the University of the Free State enrolled for above mentioned module. Two ICT audit surveys were used to gather data. This study used two modes of evaluation: Jung and Latchem’s (2007 quality indicators for DE and comparison. The findings highlight ready access to ICT, technical support, appropriate guidance and support by knowledgeable, innovative and committed facilitators and the creation of a sense of community as imperatives for teaching education leaders ICT skills and knowledge.

  12. Dosimetric characteristics of a new unshielded silicon diode and its application in clinical photon and electron beams

    International Nuclear Information System (INIS)

    Griessbach, Irmgard; Lapp, Markus; Bohsung, Joerg; Gademann, Guenther; Harder, Dietrich

    2005-01-01

    Shielded p-silicon diodes, frequently applied in general photon-beam dosimetry, show certain imperfections when applied in the small photon fields occurring in stereotactic or intensity modulated radiotherapy (IMRT), in electron beams and in the buildup region of photon beam dose distributions. Using as a study object the shielded p-silicon diode PTW 60008, well known for its reliable performance in general photon dosimetry, we have identified these imperfections as effects of electron scattering at the metallic parts of the shielding. In order to overcome these difficulties a new, unshielded diode PTW 60012 has been designed and manufactured by PTW Freiburg. By comparison with reference detectors, such as thimble and plane-parallel ionization chambers and a diamond detector, we could show the absence of these imperfections. An excellent performance of the new unshielded diode for the special dosimetric tasks in small photon fields, electron beams and build-up regions of photon beams has been observed. The new diode also has an improved angular response. However, due to its over-response to low-energy scattered photons, its recommended range of use does not include output factor measurements in large photon fields, although this effect can be compensated by a thin auxiliary lead shield

  13. SOLUTION OF MICROECONOMICS ASSIGNMENTS BY THE MEANS OF PROGRAM MODULES ISPEZ ON THE DISTANCE PLATFORM MOODLE

    Directory of Open Access Journals (Sweden)

    V. М. Kobets

    2010-04-01

    Full Text Available In article basic aspects introduction integrated environment verification knowledge students from microeconomic are expounded. It is considered structure of Decision Environmental with the built-in program modules (mathematical and graphical editors for the decision of typical assignments from microeconomics during the current and final control of students’ knowledges of different forms of teaching.

  14. SU-E-T-446: Evaluation of the Dosimetric Properties of a Diode Detector to Proton Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Teran, A [Loma Linda University Medical Center, Loma Linda, CA (United States); San Diego State University, San Diego, CA (United States); McAuley, G; Slater, J M [Loma Linda University, Loma Linda, CA (United States); Slater, J D; Wroe, A [Loma Linda University Medical Center, Loma Linda, CA (United States)

    2014-06-01

    Purpose: To test the PTW PR60020 proton dosimetry diode in radiation fields relevant to proton radiosurgery applications and evaluate its suitability as a high resolution, real time dosimetry device. Methods: Data was collected using our standard nominal radiosurgery energies of 126 MeV and 155 MeV through a single stage scattering system, corresponding to a range of 9.7 and 15 cm in water respectively. Various beam modulations were tested as part of this study. Depth dose and beam profile measurements were completed with the PTW PR60020 dosimetry diode with comparative measurements using a PTW Markus ionization chamber and EBT2 Gafchromic film. Monte Carlo simulations were also completed for comparison. Results: The single 1 mm{sup 2} by 20 μm thick sensitive volume allowed for high spatial resolution measurements while maintaining sufficient sensitive volume to ensure that measurements could be completed without excessive beam delivery. Depth dose profiles exhibited negligible LET dependence which typically impacts film and other solid state dosimetry devices, while beam ranges measured with the PTW diode were within 1 mm of ion chamber data. In an edge on arrangement beam profiles were also measured within 0.5 mm full-width at half-maximum at various depths as compared to film and simulation data. Conclusion: The PTW PR60020 proved to be a very useful radiation metrology apparatus for proton radiosurgery applications. Its waterproof and rugged construction allowed for easy deployment in phantoms or water tanks that are commonly used in proton radiosurgery QA. Dosimetrically, the diode exhibited negligible LET dependence as a function of depth, while in edge on arrangement to the incident proton beam it facilitated the measurement of beam profiles with a spatial resolution comparable to both Monte Carlo and film measurements. This project was sponsored in part by funding from the Department of Defense (DOD# W81XWH-BAA-10-1)

  15. Theory and Validation for the Collision Module

    DEFF Research Database (Denmark)

    Simonsen, Bo Cerup

    1999-01-01

    This report describes basic modelling principles, the theoretical background and validation examples for the Collision Module for the computer program DAMAGE.......This report describes basic modelling principles, the theoretical background and validation examples for the Collision Module for the computer program DAMAGE....

  16. SU-F-T-16: Experimental Determination of Ionization Chamber Correction Factors for In-Phantom Measurements of Reference Air Kerma Rate and Absorbed Water Dose Rate of Brachytherapy 192Ir Source

    International Nuclear Information System (INIS)

    Chan, M; Lee, V; Wong, M; Leung, R; Law, G; Lee, K; Cheung, S; Tung, S

    2016-01-01

    Purpose: Following the method of in-phantom measurements of reference air kerma rate (Ka) at 100cm and absorbed water dose rate (Dw1) at 1cm of high-dose-rate 192Ir brachytherapy source using 60Co absorbed-dose-to-water calibrated (ND,w,60Co) ionization chamber (IC), we experimentally determined the in-phantom correction factors (kglob) of the PTW30013 (PTW, Freiburg, Germany) IC by comparing the Monte Carlo (MC)-calculated kglob of the other PTW30016 IC. Methods: The Dw1 formalism of in-phantom measurement is: M*ND,w,60Co*(kglob)Dw1, where M is the collected charges, and (kglob)Dw1 the in-phantom Dw1 correction factor. Similarly, Ka is determined by M*ND,w,60Co*(kglob)ka, where (kglob)ka the in-phantom Ka correction factor. Two thimble ICs PTW30013 and another PTW30016 having a ND,w,60Co from the German primary standard laboratory (PTB) were simultaneously exposed to the microselectron 192Ir v2 source at 8cm in a PMMA phantom. A reference well chamber (PTW33004) with a PTB transfer Ka calibration Nka was used for comparing the in-phantom measurements to derive the experimental (kglob)ka factors. We determined the experimental (kglob)Dw1 of the PTW30013 by comparing the PTW30016 measurements with MC-calculated (kglob)Dw1. Results: Ka results of the PTW30016 based on ND,w,60Co and MC-calculated (kglob)ka differ from the well chamber results based on Nka by 1.6% and from the manufacturer by 1.0%. Experimental (kglob)ka factors for the PTW30016 and two other PTW30013 are 0.00683, 0.00681 and 0.00679, and vary <0.5% with 1mm source positioning uncertainty. Experimental (kglob)Dw1 of the PTW30013 ICs are 75.3 and 75.6, and differ by 1.6% from the conversion by dose rate constant from the AAPM report 229. Conclusion: The 1.7% difference between MC and experimental (kglob)ka for the PTW30016 IC is within the PTB 2.5% expanded uncertainty in Ka calibration standard. Using a single IC with ND,w,60Co to calibrate the brachytherapy source and dose output in external

  17. Health Occupations Module. The Integumentary System.

    Science.gov (United States)

    Temple Univ., Philadelphia, PA. Div. of Vocational Education.

    This module on the integumentary system is one of eight modules designed for individualized instruction in health occupations education programs at both the secondary and postsecondary levels. This module contains an introduction to the module topic, objectives (e.g., list and describe the types of glands formed in the skin, and explain the…

  18. Modulating wind power plant output using different frequency modulation components for damping grid oscillations

    DEFF Research Database (Denmark)

    2017-01-01

    A method, controller, wind power plant, and computer program product are disclosed for operating a wind power plant comprising a plurality of wind turbines, the wind power plant producing a plant power output. The method comprises receiving a modulation request signal indicating a requested...... modulation of the plant power output, the requested modulation specifying a modulation frequency. The method further comprises generating a respective power reference signal for each of at least two wind turbines of the plurality of wind turbines selected to fulfill the requested modulation, Each generated...... power reference signal includes a respective modulation component corresponding to a portion of the requested modulation and having a frequency different than the modulation frequency....

  19. Initial testing of a pixelated silicon detector prototype in proton therapy.

    Science.gov (United States)

    Wroe, Andrew J; McAuley, Grant; Teran, Anthony V; Wong, Jeannie; Petasecca, Marco; Lerch, Michael; Slater, James M; Rozenfeld, Anatoly B

    2017-09-01

    As technology continues to develop, external beam radiation therapy is being employed, with increased conformity, to treat smaller targets. As this occurs, the dosimetry methods and tools employed to quantify these fields for treatment also have to evolve to provide increased spatial resolution. The team at the University of Wollongong has developed a pixelated silicon detector prototype known as the dose magnifying glass (DMG) for real-time small-field metrology. This device has been tested in photon fields and IMRT. The purpose of this work was to conduct the initial performance tests with proton radiation, using beam energies and modulations typically associated with proton radiosurgery. Depth dose and lateral beam profiles were measured and compared with those collected using a PTW parallel-plate ionization chamber, a PTW proton-specific dosimetry diode, EBT3 Gafchromic film, and Monte Carlo simulations. Measurements of the depth dose profile yielded good agreement when compared with Monte Carlo, diode and ionization chamber. Bragg peak location was measured accurately by the DMG by scanning along the depth dose profile, and the relative response of the DMG at the center of modulation was within 2.5% of that for the PTW dosimetry diode for all energy and modulation combinations tested. Real-time beam profile measurements of a 5 mm 127 MeV proton beam also yielded FWHM and FW90 within ±1 channel (0.1 mm) of the Monte Carlo and EBT3 film data across all depths tested. The DMG tested here proved to be a useful device at measuring depth dose profiles in proton therapy with a stable response across the entire proton spread-out Bragg peak. In addition, the linear array of small sensitive volumes allowed for accurate point and high spatial resolution one-dimensional profile measurements of small radiation fields in real time to be completed with minimal impact from partial volume averaging. © 2017 The Authors. Journal of Applied Clinical Medical Physics published

  20. Bactericidal active ingredient in cryopreserved plasma-treated water with the reduced-pH method for plasma disinfection

    Science.gov (United States)

    Kitano, Katsuhisa; Ikawa, Satoshi; Nakashima, Yoichi; Tani, Atsushi; Yokoyama, Takashi; Ohshima, Tomoko

    2016-09-01

    For the plasma disinfection of human body, plasma sterilization in liquid is crucial. We found that the plasma-treated water (PTW) has strong bactericidal activity under low pH condition. Physicochemical properties of PTW is discussed based on chemical kinetics. Lower temperature brings longer half-life and the bactericidal activity of PTW can be kept by cryopreservation. High performance PTW, corresponding to the disinfection power of 22 log reduction (B. subtilis spore), can be obtained by special plasma system equipped with cooling device. This is equivalent to 65% H2O2, 14% sodium hypochlorite and 0.33% peracetic acid, which are deadly poison for human. But, it is deactivated soon at higher temperature (4 sec. at body temperature), and toxicity to human body seems low. For dental application, PTW was effective on infected models of human extracted tooth. Although PTW has many chemical components, respective chemical components in PTW were isolated by ion chromatography. In addition to peaks of H2O2, NO2- and NO3-, a specific peak was detected. and only this fraction had bactericidal activity. Purified active ingredient of PTW is the precursor of HOO, and further details will be discussed in the presentation. MEXT (15H03583, 23340176, 25108505). NCCE (23-A-15).

  1. Improving the human readability of Arden Syntax medical logic modules using a concept-oriented terminology and object-oriented programming expressions.

    Science.gov (United States)

    Choi, Jeeyae; Bakken, Suzanne; Lussier, Yves A; Mendonça, Eneida A

    2006-01-01

    Medical logic modules are a procedural representation for sharing task-specific knowledge for decision support systems. Based on the premise that clinicians may perceive object-oriented expressions as easier to read than procedural rules in Arden Syntax-based medical logic modules, we developed a method for improving the readability of medical logic modules. Two approaches were applied: exploiting the concept-oriented features of the Medical Entities Dictionary and building an executable Java program to replace Arden Syntax procedural expressions. The usability evaluation showed that 66% of participants successfully mapped all Arden Syntax rules to Java methods. These findings suggest that these approaches can play an essential role in the creation of human readable medical logic modules and can potentially increase the number of clinical experts who are able to participate in the creation of medical logic modules. Although our approaches are broadly applicable, we specifically discuss the relevance to concept-oriented nursing terminologies and automated processing of task-specific nursing knowledge.

  2. Medical Terminology: Suffixes. Health Occupations Education Module.

    Science.gov (United States)

    Temple Univ., Philadelphia, PA. Div. of Vocational Education.

    This module on medical terminology (suffixes) is one of 17 modules designed for individualized instruction in health occupations education programs at both the secondary and postsecondary levels. This module consists of an introduction to the module topic, a list of resources needed, and three learning experiences. The first two learning…

  3. Health Occupations Module. The Skeletal System--I.

    Science.gov (United States)

    Temple Univ., Philadelphia, PA. Div. of Vocational Education.

    This module on the skeletal system is one of eight modules designed for individualized instruction in health occupations education programs at both the secondary and postsecondary levels. This module contains an introduction to the module topic, three objectives (e.g., define the skeletal system and list its functions), and three learning…

  4. Health Occupations Module. The Skeletal System--II.

    Science.gov (United States)

    Temple Univ., Philadelphia, PA. Div. of Vocational Education.

    This module on the skeletal system is one of eight modules designed for individualized instruction in health occupations education programs at both the secondary and postsecondary levels. This module contains an introduction to the module topic, two objectives (e.g., list the types of joints and movements, and give examples), and two learning…

  5. FASTBUS Snoop Diagnostic Module

    International Nuclear Information System (INIS)

    Walz, H.V.; Downing, R.

    1980-11-01

    Development of the FASTBUS Snoop Module, undertaken as part of the prototype program for the new interlaboratory data bus standard, is described. The Snoop Module resides on a FASTBUS crate segment and provides diagnostic monitoring and testing capability. Communication with a remote host computer is handled independent of FASTBUS through a serial link. The module consists of a high-speed ECL front-end to monitor and single-step FASTBUS cycles, a master-slave interface, and a control microprocessor with serial communication ports. Design details and performance specifications of the prototype module are reported. 9 figures, 1 table

  6. Development and application of programs to measure modulation transfer function, noise power spectrum and detective quantum efficiency.

    Science.gov (United States)

    Padgett, R; Kotre, C J

    2005-01-01

    This project aimed to produce programs to calculate the modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) of digital X-ray systems, given a suitable digital image. The MTF was calculated using the edge technique and the NPS was calculated from a flat field image. Both programs require a suitably edited DICOM image as input. The DQE was then calculated from the output of MTF and NPS programs. This required data external to the DQE program to estimate the number of quanta per mm2 in the beam which formed the NPS image. All three programs run independent of each other on a PC and require no special software to be installed. Results for MTF, NPS and DQE for a Philips AC3 CR system are presented. In addition, the results for MTF from a Siemens Duo CT scanner with a specially designed PTFE edge are also shown.

  7. Dosimetry in radiotherapy with natural diamond detectors

    International Nuclear Information System (INIS)

    De Angelis, C.; Onori, S.; Pacilio, M.; Cirrone, G.A.P.; Cuttone, G.; Raffaele, L.; Bucciolini, M.; Mazzocchi, S.

    2002-01-01

    There is wide interest in the use of diamond detectors for dosimetry in radiotherapy mainly because of the small dimensions, radiation hardness, nearly tissue equivalence of sensitive material and capability to deliver the dosimetric response 'on line'. In order to assess the dosimetric properties of PTW Riga diamond detectors type 60003, experiments were performed in conventional (high energy photon and electron) therapy beams as well as in proton therapy beams. The main detector features investigated were reproducibility of response, dose-signal relationship, temperature dependence, dose-rate dependence, energy dependence and angular dependence. High energy photons (6-25 MV) and electrons (6-22 MeV), available at the Radiotherapy Department of the Florence University, were used for investigating the general properties. Two different PTW diamond detectors of the same type were used to evidence inter-sample differences. The beam quality dependence of the detector response is probably the most critical point and this statement is of particular relevance for proton dosimetry since the proton LET changes with depth in the medium. Mainly because of the little information available on detector sensitivity variations with beam energy, the use of diamonds for clinical proton dosimetry is not widespread. In two recent papers a sensitivity dependence on proton energy of a natural PTW diamond detector has been reported. Due to the necessity to characterise each diamond detector individually the PTW Riga natural diamond detector in operation at the LNS-INFN, Catania, Italy was tested with the local proton beam line. This experiment is of main concern because this proton beam, produced by a superconducting cyclotron and used for ocular melanoma treatment, is available only since 2001 (CATANA beam). The first patient has been treated in February 2002. Proton irradiations were performed with non modulated and modulated 62 MeV beams. Attention was focused on diamond sensitivity

  8. Commissioning of a PTW 34070 large-area plane-parallel ionization chamber for small field megavoltage photon dosimetry.

    Science.gov (United States)

    Kupfer, Tom; Lehmann, Joerg; Butler, Duncan J; Ramanathan, Ganesan; Bailey, Tracy E; Franich, Rick D

    2017-11-01

    This study investigates a large-area plane-parallel ionization chamber (LAC) for measurements of dose-area product in water (DAP w ) in megavoltage (MV) photon fields. Uniformity of electrode separation of the LAC (PTW34070 Bragg Peak Chamber, sensitive volume diameter: 8.16 cm) was measured using high-resolution microCT. Signal dependence on angle α of beam incidence for square 6 MV fields of side length s = 20 cm and 1 cm was measured in air. Polarity and recombination effects were characterized in 6, 10, and 18 MV photons fields. To assess the lateral setup tolerance, scanned LAC profiles of a 1 × 1 cm 2 field were acquired. A 6 MV calibration coefficient, N D ,w, LAC , was determined in a field collimated by a 5 cm diameter stereotactic cone with known DAP w . Additional calibrations in 10 × 10 cm 2 fields at 6, 10, and 18 MV were performed. Electrode separation is uniform and agrees with specifications. Volume-averaging leads to a signal increase proportional to ~1/cos(α) in small fields. Correction factors for polarity and recombination range between 0.9986 to 0.9996 and 1.0007 to 1.0024, respectively. Off-axis displacement by up to 0.5 cm did not change the measured signal in a 1 × 1 cm 2 field. N D ,w, LAC was 163.7 mGy cm -2 nC -1 and differs by +3.0% from the coefficient derived in the 10 × 10 cm 2 6 MV field. Response in 10 and 18 MV fields increased by 1.0% and 2.7% compared to 6 MV. The LAC requires only small correction factors for DAP w measurements and shows little energy dependence. Lateral setup errors of 0.5 cm are tolerated in 1 × 1 cm 2 fields, but beam incidence must be kept as close to normal as possible. Calibration in 10 × 10 fields is not recommended because of the LAC's over-response. The accuracy of relative point-dose measurements in the field's periphery is an important limiting factor for the accuracy of DAP w measurements. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on

  9. Adolescence Education: Physical Aspect, Module One; Social Aspects, Module Two; Sex Roles, Module Three; Sexually Transmitted Diseases, Module Four.

    Science.gov (United States)

    United Nations Educational, Scientific and Cultural Organization, Bangkok (Thailand). Principal Regional Office for Asia and the Pacific.

    Adolescence Education is a family life education training program designed to assist young people in their physical, social, emotional, and moral development as they prepare for adulthood, marriage, parenthood, aging, and social relationships in the context of family and society. This package consists of four individually bound modules: (1)…

  10. Programming Nanoparticles in Multiscale: Optically Modulated Assembly and Phase Switching of Silicon Nanoparticle Array.

    Science.gov (United States)

    Wang, Letian; Rho, Yoonsoo; Shou, Wan; Hong, Sukjoon; Kato, Kimihiko; Eliceiri, Matthew; Shi, Meng; Grigoropoulos, Costas P; Pan, Heng; Carraro, Carlo; Qi, Dongfeng

    2018-03-27

    Manipulating and tuning nanoparticles by means of optical field interactions is of key interest for nanoscience and applications in electronics and photonics. We report scalable, direct, and optically modulated writing of nanoparticle patterns (size, number, and location) of high precision using a pulsed nanosecond laser. The complex nanoparticle arrangement is modulated by the laser pulse energy and polarization with the particle size ranging from 60 to 330 nm. Furthermore, we report fast cooling-rate induced phase switching of crystalline Si nanoparticles to the amorphous state. Such phase switching has usually been observed in compound phase change materials like GeSbTe. The ensuing modification of atomic structure leads to dielectric constant switching. Based on these effects, a multiscale laser-assisted method of fabricating Mie resonator arrays is proposed. The number of Mie resonators, as well as the resonance peaks and dielectric constants of selected resonators, can be programmed. The programmable light-matter interaction serves as a mechanism to fabricate optical metasurfaces, structural color, and multidimensional optical storage devices.

  11. On the accuracy of self-made dose planning system based on the static field measurements of cobalt unit Theratron 780C

    International Nuclear Information System (INIS)

    Treer, T.; Polgar, I.

    1995-01-01

    In connection with the installation of the new Theratron 780C cobalt unit the authors demonstrate that the planning program developed in Pecs 8 years ago can be used even for the new cobalt unit. The computed results are in good agreement with the measurements made by the PTW MP3 water phantom using the Mephysto program. (N.T.) 3 refs., 4 figs

  12. The program of group constants creation (SMOK) on basis libraries of evaluated nuclear data in ENDE/B format for physical module FORTUN-88

    International Nuclear Information System (INIS)

    Borisov, A.A.

    1991-01-01

    The SMOK program for creation of group microconstants in the FORTUN-88 physical module format providing for calculations of neutron transport by the Monte Carlo method is described. The program processes files of evaluated neutron nuclear data in the ENDF-4 format. The constant structure gives an apportunity to simulate the process of neutron collisions with matter in details. The program service capabilities provide for graphical constant comparison. 11 refs

  13. Medical Terminology: Prefixes. Health Occupations Education Module.

    Science.gov (United States)

    Temple Univ., Philadelphia, PA. Div. of Vocational Education.

    This module on medical terminology (prefixes) is one of 17 modules designed for individualized instruction in health occupations education programs at both the secondary and postsecondary levels. This module consists of an introduction to prefixes, a list of resources needed, and three learning experiences. Each learning experience contains an…

  14. Module 13: Bulk Packaging Shipments by Highway

    International Nuclear Information System (INIS)

    Przybylski, J.L.

    1994-07-01

    The Hazardous Materials Modular Training Program provides participating United States Department of Energy (DOE) sites with a basic, yet comprehensive, hazardous materials transportation training program for use onsite. This program may be used to assist individual program entities to satisfy the general awareness, safety training, and function specific training requirements addressed in Code of Federal Regulation (CFR), Title 49, Part 172, Subpart H -- ''Training.'' Module 13 -- Bulk Packaging Shipments by Highway is a supplement to the Basic Hazardous Materials Workshop. Module 13 -- Bulk Packaging Shipments by Highway focuses on bulk shipments of hazardous materials by highway mode, which have additional or unique requirements beyond those addressed in the ten module core program. Attendance in this course of instruction should be limited to those individuals with work experience in transporting hazardous materials utilizing bulk packagings and who have completed the Basic Hazardous Materials Workshop or an equivalent. Participants will become familiar with the rules and regulations governing the transportation by highway of hazardous materials in bulk packagings and will demonstrate the application of these requirements through work projects and examination

  15. Reliability improvement of multiversion software by exchanging modules

    International Nuclear Information System (INIS)

    Shima, Kazuyuki; Matsumoto, Ken-ichi; Torii, Koji

    1996-01-01

    In this paper, we proposes a method to improve reliability of multiversion software. In CER proposed in, checkpoints are put in versions of program and errors of versions are detected and recovered at the checkpoints. It prevent versions from failing and improve the reliability of multiversion software. But it is point out that CER decreases the reliability of the multiversion software if the detection and recovery of errors are assumed to be able to fail. In the method proposed in this paper, versions of program are developed following the same module specifications. When failures of versions of program are detected, faulty modules are identified and replaced them to other modules. It create versions without faulty modules and improve the reliability of multiversion software. The failure probability of multiversion software is estimated to become about a hundredth of the failure probability by the proposed method where the failure probability of each version is 0.000698, the number of versions is 5 and the number of modules is 20. (author)

  16. Medical Terminology: Root Words. Health Occupations Education Module.

    Science.gov (United States)

    Temple Univ., Philadelphia, PA. Div. of Vocational Education.

    This module on medical terminology (root words) is one of 17 modules designed for individualized instruction in health occupations education programs at both the secondary and postsecondary levels. This module consists of an introduction to root words, a list of resources needed, procedures for using the module, a list of terminology used in the…

  17. Programmable synchronous communications module

    International Nuclear Information System (INIS)

    Horelick, D.

    1979-10-01

    The functional characteristics of a programmable, synchronous serial communications CAMAC module with buffering in block format are described. Both bit and byte oriented protocols can be handled in full duplex depending on the program implemented. The main elements of the module are a Signetics 2652 Multi-Protocol Communications Controller, a Zilog Z-808 8 bit microprocessor with PROM and RAM, and FIFOs for buffering

  18. Electromechanical Componentry. High-Technology Training Module.

    Science.gov (United States)

    Lindemann, Don

    This training module on electromechanical components contains 10 units for a two-year vocational program packaging system equipment control course at Wisconsin Indianhead Technical College. This module describes the functions of electromechanical devices essential for understanding input/output devices for Programmable Logic Control (PLC)…

  19. HEALTH - module for assessment of stochastic health effects after nuclear accidents

    International Nuclear Information System (INIS)

    Raicevic, J.J.; Gajic, M.; Popovic, Z.

    2003-01-01

    In this paper the program module HEALTH for assessment of stochastic health effects in the case of nuclear accidents is presented. Program module HEALTH is a part of the new European real-time computer system RODOS for nuclear emergency and preparedness. Some of the key features of module HEALTH are presented, and some possible further improvements are discussed (author)

  20. Coded Modulation in C and MATLAB

    Science.gov (United States)

    Hamkins, Jon; Andrews, Kenneth S.

    2011-01-01

    This software, written separately in C and MATLAB as stand-alone packages with equivalent functionality, implements encoders and decoders for a set of nine error-correcting codes and modulators and demodulators for five modulation types. The software can be used as a single program to simulate the performance of such coded modulation. The error-correcting codes implemented are the nine accumulate repeat-4 jagged accumulate (AR4JA) low-density parity-check (LDPC) codes, which have been approved for international standardization by the Consultative Committee for Space Data Systems, and which are scheduled to fly on a series of NASA missions in the Constellation Program. The software implements the encoder and decoder functions, and contains compressed versions of generator and parity-check matrices used in these operations.

  1. Environmental testing of terrestrial flat plate photovoltaic modules

    Science.gov (United States)

    Hoffman, A.; Griffith, J.

    1979-01-01

    The Low-Cost Solar Array (LSA) Project at the Jet Propulsion Laboratory has as one objective: the development and implementation of environmental tests for flat plate photovoltaic modules as part of the Department of Energy's terrestrial photovoltaic program. Modules procured under this program have been subjected to a variety of laboratory tests intended to simulate service environments, and the results of these tests have been compared to available data from actual field service. This comparison indicates that certain tests (notably temperature cycling, humidity cycling, and cyclic pressure loading) are effective indicators of some forms of field failures. Other tests have yielded results useful in formulating module design guidelines. Not all effects noted in field service have been successfully reproduced in the laboratory, however, and work is continuing in order to improve the value of the test program as a tool for evaluating module design and workmanship. This paper contains a review of these ongoing efforts and an assessment of significant test results to date.

  2. Pilot implementation of training modules of the EMERALD program in Brazil

    International Nuclear Information System (INIS)

    Costa, Paulo R.; Yoshimura, Elisabeth M.; Okuno, Emico; Nersissian, Denise Y.; Terini, Ricardo A.

    2014-01-01

    A research cooperation program was established between the Institute of Physics of the University of Sao Paulo and the King's College of London to conduct the translation to Portuguese language, adaptation and update of the X-Ray Diagnostic Radiology training module of the Emerald Program (www.emerald2.eu/cd/Emerald2/). The Emerald Program teaching material in X-Ray Diagnostic Radiology is divided in ten topics covering the basics of Diagnostic Radiology, Quality Control and Radiation Protection. The referred work, besides the translation of the texts into Portuguese, comprised the review of the previously produced material. During the review process, it was decided to update some of the training tasks and add more information related to current topics, such as digital X-ray imaging modalities, multislice computed tomography and tomosynthesis. These new additions will also be available in English. The translated or written texts have been submitted to a cross-reviewing process by the co-authors in order to standardize the language. Moreover, national radiological protection recommendations were included to assist the users of the teaching material with the Brazilian rules of radiation safety and quality control in X-ray medical applications. Part of the material was submitted to a validation and also to a practical assessment process by means of a critical analysis by experts in Medical Physics education during a workshop held in Sao Paulo in March 2014. Finally, a pilot implementation has been organized in order to do the last adjustments before making the material available to other users in Portuguese language. Further assessment and feedback procedures were planned in both London and Sao Paulo, aiming to evaluate and disseminate the final product. (author)

  3. VERIDOS: a new tool for quality assurance for intensity modulated radiotherapy.

    Science.gov (United States)

    Wiezorek, Tilo; Schwedas, Michael; Scheithauer, Marcel; Salz, Henning; Bellemann, Matthias; Wendt, Thomas G

    2002-12-01

    The use of intensity modulated radiation fields needs an extended quality assurance concept. This consists of a linac related part and a case related part. Case related means the verification of an individual treatment plan, optimized on a CT data set of an individual patient and prepared for the treatment of this patient. This part of the quality assurance work is usually time consuming, delivers only partially quantitative results and is uncomfortable without additional help. It will be shown in this paper how the software VERIDOS will improve the optimization of the case related part of the quality assurance work. The main function of the software is the quantitative comparison of the calculated dose distribution from the treatment planning software with the measured dose distribution of an irradiated phantom. Several additional functions will be explained. Two self-developed phantoms made of RW3 (solid water) and GAFCHROMIC films or Kodak EDR2 films for the measurement of the dose distributions were used. VERIDOS was tested with the treatment planning systems Helay-TMS and Brainscan. VERIDOS is a suitable tool for the import of calculated dose matrices from the treatment planning systems Helax-TMS and Brainscan and of measured dose matrices exported from the dosimetry software Mephysto (PTW). The import from other treatment planning systems and scanning software applications for film dosimetry is generally possible. In such case the import function has to be adapted to the special header of the import matrix. All other functions of this software tool like normalization (automatically, manually), working with corrections (ground substraction, factors), overlay/comparison of dose distributions, difference matrix, cutting function (profiles) and export functions work reliable. VERIDOS improves the optimization of the case related part of the quality assurance work for intensity modulated radiation therapy (IMRT). The diverse functions of the software offer the

  4. VERIDOS: A new tool for quality assurance for intensity modulated radiotherapy

    International Nuclear Information System (INIS)

    Wiezorek, T.; Schwedas, M.; Scheithauer, M.; Salz, H.; Wendt, T.G.; Bellemann, M.

    2002-01-01

    Background: The use of intensity modulated radiation fields needs an extended quality assurance concept. This consists of a linac related part and a case related part. Case related means the verification of an individual treatment plan, optimized on a CT data set of an individual patient and prepared for the treatment of this patient. This part of the quality assurance work is usually time consuming, delivers only partially quantitative results and is uncomfortable without additional help. It will be shown in this paper how the software VERIDOS will improve the optimization of the case related part of the quality assurance work. Material and Methods: The main function of the software is the quantitative comparison of the calculated dose distribution from the treatment planning software with the measured dose distribution of an irradiated phantom. Several additional functions will be explained. Two self-developed phantoms made of RW3 (solid water) and GAFCHROMIC films or Kodak EDR2 films for the measurement of the dose distributions were used. VERIDOS was tested with the treatment planning systems Helax-TMS and Brainscan. Results: VERIDOS is a suitable tool for the import of calculated dose matrices from the treatment planning systems Helax-TMS and Brainscan and of measured dose matrices exported from the dosimetry software Mephysto (PTW). The import from other treatment planning systems and scanning software applications for film dosimetry is generally possible. In such case the import function has to be adapted to the special header of the import matrix. All other functions of this software tool like normalization (automatically, manually), working with corrections (ground substraction, factors), overlay/comparison of dose distributions, difference matrix, cutting function (profiles) and export functions work reliable. Conclusions: VERIDOS improves the optimization of the case related part of the quality assurance work for intensity modulated radiation therapy

  5. Modular crystals as modulated structures

    DEFF Research Database (Denmark)

    Elcoro, L.; Perez-Mato, J.M.; Friese, K.

    2008-01-01

    The use of the superspace formalism is extended to the description and refinement of the homologous series of modular structures with two symmetry-related modules with different orientations. The lillianite homologous series has been taken as a study case. Starting from a commensurate modulated...... composite description with two basic subsystems corresponding to the two different modules, it is shown how a more efficient description can be achieved using so-called zigzag modulation functions. These linear zigzag modulations, newly implemented in the program JANA2006, have very large fixed amplitudes...... and introduce in the starting model the two orientations of the underlying module sublattices. We show that a composite approach with this type of function, which treats the cations and anions as two separate subsystems forming a misfit compound, is the most appropriate and robust method for the refinements....

  6. Neutronic design for the TFTR lithium blanket module

    International Nuclear Information System (INIS)

    Cheng, E.T.; Engholm, B.A.; Su, S.D.

    1981-01-01

    The preliminary design of a lithium blanket module (LBM) to be installed and tested in the TFTR has been performed under subcontract to PPPL and EPRI. The objectives of the LBM program are calculation and measurement of neutron fluences and tritium production in a breeding blanket module using state of art techniques, comparison of calculations with measurements, and acquisition of operational experience with a fusion reactor blanket module. The neutronic design of the LBM is one of the key areas of this program in which the LBM composition and geometry are optimized and the boundary material effects on the tritium production in the blanket module are explored. The concept of employing sintered Li/sub 2/O pellets in tubes is proposed for the blanket design

  7. Volcano!: An Event-Based Science Module. Student Edition. Geology Module.

    Science.gov (United States)

    Wright, Russell G.

    This book is designed for middle school students to learn scientific literacy through event-based science. Unlike traditional curricula, the event-based earth science module is a student-centered, interdisciplinary, inquiry-oriented program that emphasizes cooperative learning, teamwork, independent research, hands-on investigations, and…

  8. SCALPLO - a universal program for plotting flux output from SCALE modules and related programs. User's manual

    International Nuclear Information System (INIS)

    Hersman, A.; Leege, P.F.A. de; Hoogenboom, J.E.

    1992-04-01

    The FORTRAN-77 program SCALPLO is being developed to make an easy and quick graphic survey of flux and/or power data calculated with SCALE modules or other core calculation or shielding codes. The basic plot functions it can perform are one- and two-dimensional plots of flux or power distributions and flux energy spectra. More specifically it can produce plots of the flux distribution in a one-dimensional geometry for one or more energy groups in one figure. It can also plot the flux distribution along a cut through a two- or three-dimensional geometry along one of the coordinate axes and it can plot a two-dimensional view of the flux distribution of a two-dimensional geometry or of a plane cut through a three-dimensional geometry. The same can be done for the power distribution in a system. Furthermore SCALPLO can plot the particle flux spectrum as a function of energy, either as group fluxes or as group fluxes per unit energy or per unit lethargy. (orig./HP)

  9. Gene set-based module discovery in the breast cancer transcriptome

    Directory of Open Access Journals (Sweden)

    Zhang Michael Q

    2009-02-01

    Full Text Available Abstract Background Although microarray-based studies have revealed global view of gene expression in cancer cells, we still have little knowledge about regulatory mechanisms underlying the transcriptome. Several computational methods applied to yeast data have recently succeeded in identifying expression modules, which is defined as co-expressed gene sets under common regulatory mechanisms. However, such module discovery methods are not applied cancer transcriptome data. Results In order to decode oncogenic regulatory programs in cancer cells, we developed a novel module discovery method termed EEM by extending a previously reported module discovery method, and applied it to breast cancer expression data. Starting from seed gene sets prepared based on cis-regulatory elements, ChIP-chip data, and gene locus information, EEM identified 10 principal expression modules in breast cancer based on their expression coherence. Moreover, EEM depicted their activity profiles, which predict regulatory programs in each subtypes of breast tumors. For example, our analysis revealed that the expression module regulated by the Polycomb repressive complex 2 (PRC2 is downregulated in triple negative breast cancers, suggesting similarity of transcriptional programs between stem cells and aggressive breast cancer cells. We also found that the activity of the PRC2 expression module is negatively correlated to the expression of EZH2, a component of PRC2 which belongs to the E2F expression module. E2F-driven EZH2 overexpression may be responsible for the repression of the PRC2 expression modules in triple negative tumors. Furthermore, our network analysis predicts regulatory circuits in breast cancer cells. Conclusion These results demonstrate that the gene set-based module discovery approach is a powerful tool to decode regulatory programs in cancer cells.

  10. Volcano!: An Event-Based Science Module. Teacher's Guide. Geology Module.

    Science.gov (United States)

    Wright, Russell G.

    This book is designed for middle school earth science teachers to help their students learn scientific literacy through event-based science. Unlike traditional curricula, the event-based earth science module is a student-centered, interdisciplinary, inquiry-oriented program that emphasizes cooperative learning, teamwork, independent research,…

  11. Installing Python Modules with pip

    OpenAIRE

    Fred Gibbs

    2013-01-01

    This lesson shows you how to download and install Python modules. There are many ways to install external modules, but for the purposes of this lesson, we’re going to use a program called pip. As of Python 2.7.9 and newer, pip is installed by default. This tutorial will be helpful for anyone using older versions of Python (which are still quite common).

  12. The use of atmospheric pressure plasma-treated water as a source of nitrite for emulsion-type sausage.

    Science.gov (United States)

    Jung, Samooel; Kim, Hyun Joo; Park, Sanghoo; In Yong, Hae; Choe, Jun Ho; Jeon, Hee-Joon; Choe, Wonho; Jo, Cheorun

    2015-10-01

    We investigated the possible use of atmospheric pressure plasma-treated water (PTW) as a nitrite source in curing process. Emulsion-type sausages were manufactured with PTW, celery powder containing nitrite, and synthetic sodium nitrite at a concentration of nitrite ion 70mgkg(-1). In terms of sausage quality, there were no noticeable effects of PTW on the total aerobic bacterial counts, color, and peroxide values of sausages compared with those of celery powder and sodium nitrite throughout 28days of storage at 4°C. Sausage with added PTW had lower concentrations of residual nitrite compared to those of added celery powder and sodium nitrite during the storage period (Pnitrite-treated sausages were not different, whereas the sausage with added celery powder received the lowest scores in taste and acceptability. From the results, it is concluded that PTW can be used as a nitrite source equivalent to a natural curing agent. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. An abstract machine for module replacement

    OpenAIRE

    Walton, Chris; Krl, Dilsun; Gilmore, Stephen

    1998-01-01

    In this paper we define an abstract machine model for the mλ typed intermediate language. This abstract machine is used to give a formal description of the operation of run-time module replacement from the programming language Dynamic ML. The essential technical device which we employ for module replacement is a modification of two-space copying garbage collection.

  14. Integer-linear-programing optimization in scalable video multicast with adaptive modulation and coding in wireless networks.

    Science.gov (United States)

    Lee, Dongyul; Lee, Chaewoo

    2014-01-01

    The advancement in wideband wireless network supports real time services such as IPTV and live video streaming. However, because of the sharing nature of the wireless medium, efficient resource allocation has been studied to achieve a high level of acceptability and proliferation of wireless multimedia. Scalable video coding (SVC) with adaptive modulation and coding (AMC) provides an excellent solution for wireless video streaming. By assigning different modulation and coding schemes (MCSs) to video layers, SVC can provide good video quality to users in good channel conditions and also basic video quality to users in bad channel conditions. For optimal resource allocation, a key issue in applying SVC in the wireless multicast service is how to assign MCSs and the time resources to each SVC layer in the heterogeneous channel condition. We formulate this problem with integer linear programming (ILP) and provide numerical results to show the performance under 802.16 m environment. The result shows that our methodology enhances the overall system throughput compared to an existing algorithm.

  15. Integer-Linear-Programing Optimization in Scalable Video Multicast with Adaptive Modulation and Coding in Wireless Networks

    Directory of Open Access Journals (Sweden)

    Dongyul Lee

    2014-01-01

    Full Text Available The advancement in wideband wireless network supports real time services such as IPTV and live video streaming. However, because of the sharing nature of the wireless medium, efficient resource allocation has been studied to achieve a high level of acceptability and proliferation of wireless multimedia. Scalable video coding (SVC with adaptive modulation and coding (AMC provides an excellent solution for wireless video streaming. By assigning different modulation and coding schemes (MCSs to video layers, SVC can provide good video quality to users in good channel conditions and also basic video quality to users in bad channel conditions. For optimal resource allocation, a key issue in applying SVC in the wireless multicast service is how to assign MCSs and the time resources to each SVC layer in the heterogeneous channel condition. We formulate this problem with integer linear programming (ILP and provide numerical results to show the performance under 802.16 m environment. The result shows that our methodology enhances the overall system throughput compared to an existing algorithm.

  16. Using Instructional Design, Analyze, Design, Develop, Implement, and Evaluate, to Develop e-Learning Modules to Disseminate Supported Employment for Community Behavioral Health Treatment Programs in New York State.

    Science.gov (United States)

    Patel, Sapana R; Margolies, Paul J; Covell, Nancy H; Lipscomb, Cristine; Dixon, Lisa B

    2018-01-01

    Implementation science lacks a systematic approach to the development of learning strategies for online training in evidence-based practices (EBPs) that takes the context of real-world practice into account. The field of instructional design offers ecologically valid and systematic processes to develop learning strategies for workforce development and performance support. This report describes the application of an instructional design framework-Analyze, Design, Develop, Implement, and Evaluate (ADDIE) model-in the development and evaluation of e-learning modules as one strategy among a multifaceted approach to the implementation of individual placement and support (IPS), a model of supported employment for community behavioral health treatment programs, in New York State. We applied quantitative and qualitative methods to develop and evaluate three IPS e-learning modules. Throughout the ADDIE process, we conducted formative and summative evaluations and identified determinants of implementation using the Consolidated Framework for Implementation Research (CFIR). Formative evaluations consisted of qualitative feedback received from recipients and providers during early pilot work. The summative evaluation consisted of levels 1 and 2 (reaction to the training, self-reported knowledge, and practice change) quantitative and qualitative data and was guided by the Kirkpatrick model for training evaluation. Formative evaluation with key stakeholders identified a range of learning needs that informed the development of a pilot training program in IPS. Feedback on this pilot training program informed the design document of three e-learning modules on IPS: Introduction to IPS, IPS Job development, and Using the IPS Employment Resource Book . Each module was developed iteratively and provided an assessment of learning needs that informed successive modules. All modules were disseminated and evaluated through a learning management system. Summative evaluation revealed that

  17. Evaluation of a synthetic single-crystal diamond detector for relative dosimetry on the Leksell Gamma Knife Perfexion radiosurgery system

    Energy Technology Data Exchange (ETDEWEB)

    Mancosu, Pietro; Reggiori, Giacomo, E-mail: giacomo.reggiori@humanitas.it; Stravato, Antonella; Gaudino, Anna; Lobefalo, Francesca; Palumbo, Valentina; Tomatis, Stefano [Physics Service of Radiation Oncology Department, Clinical and Research Center, Rozzano, Milan 20098 (Italy); Navarria, Piera; Ascolese, Anna; Scorsetti, Marta [Radiation Oncology Department, Humanitas Clinical and Research Center, Rozzano, Milan 20089 (Italy); Picozzi, Piero [Neurosurgery Department, Humanitas Clinical and Research Center, Rozzano, Milan 20089 (Italy); Marinelli, Marco; Verona-Rinati, Gianluca [Dipartimento di Ingegneria Industriale, Università di Roma Tor Vergata, Roma 00133 (Italy)

    2015-09-15

    Purpose: To evaluate the new commercial PTW-60019 synthetic single-crystal microDiamond detector (PTW, Freiburg, Germany) for relative dosimetry measurements on a clinical Leksell Gamma Knife Perfexion radiosurgery system. Methods: Detector output ratios (DORs) for 4 and 8 mm beams were measured using a microDiamond (PTW-60019), a stereotactic unshielded diode [IBA stereotactic field detector (SFD)], a shielded diode (IBA photon field detector), and GafChromic EBT3 films. Both parallel and transversal acquisition directions were considered for PTW-60019 measurements. Measured DORs were compared to the new output factor reference values for Gamma Knife Perfexion (0.814 and 0.900 for 4 and 8 mm, respectively). Profiles in the three directions were also measured for the 4 mm beam to evaluate full width at half maximum (FWHM) and penumbra and to compare them with the corresponding Leksell GammaPlan profiles. Results: FWHM and penumbra for PTW-60019 differed from the calculated values by less than 0.2 and 0.3 mm, for the parallel and transversal acquisitions, respectively. GafChromic films showed FWHM and penumbra within 0.1 mm. The output ratio obtained with the PTW-60019 for the 4 mm field was 1.6% greater in transverse direction compared to the nominal value. Comparable differences up to 0.8% and 1.0% for, respectively, GafChromic films and SFD were found. Conclusions: The microDiamond PTW-60019 is a suitable detector for commissioning and routine use of Gamma Knife with good agreement of both DORs and profiles in the three directions.

  18. Tribo-performance of epoxy hybrid composites reinforced with carbon fibers and potassium titanate whiskers

    Science.gov (United States)

    Suresha, B.; Harshavardhan, B.; Ravishankar, R.

    2018-04-01

    The present investigation deals with the fabrication and characterization of epoxy reinforced with bidirectional carbon fiber mat (CF/Ep) and filled with 2.5, 5 and 7.5 wt% potassium titanate whiskers (PTw) composites. The effect of PTw loading on hardness, tensile properties and dry sliding wear behaviour of CF/Ep composite were carefully investigated in expectation of providing valuable information for the application of hybrid CF/Ep composites. Results indicated that the incorporation of PTw actually improved the hardness, tensile strength and tensile modulus of CF/Ep composites. Meanwhile, the specific wear rate of CF/Ep filled by 5 wt % PTw reached to 6.3× 10-14 m3/N-m, which is 41% lower than that of CF/Ep composite at the same dry sliding condition. It also seen that the fiber and filler worked synergistically to enhance the wear resistance. Further, for all composites the friction coefficient increases with increase in load and sliding velocity. However, PTw reinforced CF/Ep exhibited considerably higher coefficient of friction compared to unfilled ones, while PTw filler loading of 5 wt% was effective in reducing the specific wear rate of CF/Ep composite. The carbon fiber carried the applied load between the contact surfaces and protected the epoxy from severe abrasion of the counterface. At the same time, the exposed PTw out of the epoxy matrix around the fiber inhibited the direct scraping between the fiber and counterface so that the fibers could be less directly impacted during the subsequent wear process and they were protected from severe damage.

  19. Evaluation of a synthetic single-crystal diamond detector for relative dosimetry on the Leksell Gamma Knife Perfexion radiosurgery system

    International Nuclear Information System (INIS)

    Mancosu, Pietro; Reggiori, Giacomo; Stravato, Antonella; Gaudino, Anna; Lobefalo, Francesca; Palumbo, Valentina; Tomatis, Stefano; Navarria, Piera; Ascolese, Anna; Scorsetti, Marta; Picozzi, Piero; Marinelli, Marco; Verona-Rinati, Gianluca

    2015-01-01

    Purpose: To evaluate the new commercial PTW-60019 synthetic single-crystal microDiamond detector (PTW, Freiburg, Germany) for relative dosimetry measurements on a clinical Leksell Gamma Knife Perfexion radiosurgery system. Methods: Detector output ratios (DORs) for 4 and 8 mm beams were measured using a microDiamond (PTW-60019), a stereotactic unshielded diode [IBA stereotactic field detector (SFD)], a shielded diode (IBA photon field detector), and GafChromic EBT3 films. Both parallel and transversal acquisition directions were considered for PTW-60019 measurements. Measured DORs were compared to the new output factor reference values for Gamma Knife Perfexion (0.814 and 0.900 for 4 and 8 mm, respectively). Profiles in the three directions were also measured for the 4 mm beam to evaluate full width at half maximum (FWHM) and penumbra and to compare them with the corresponding Leksell GammaPlan profiles. Results: FWHM and penumbra for PTW-60019 differed from the calculated values by less than 0.2 and 0.3 mm, for the parallel and transversal acquisitions, respectively. GafChromic films showed FWHM and penumbra within 0.1 mm. The output ratio obtained with the PTW-60019 for the 4 mm field was 1.6% greater in transverse direction compared to the nominal value. Comparable differences up to 0.8% and 1.0% for, respectively, GafChromic films and SFD were found. Conclusions: The microDiamond PTW-60019 is a suitable detector for commissioning and routine use of Gamma Knife with good agreement of both DORs and profiles in the three directions

  20. SCALPLO - a universal program for plotting flux output from SCALE modules and related programs. User`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Hersman, A; Leege, P F.A. de; Hoogenboom, J E

    1992-04-01

    The FORTRAN-77 program SCALPLO is being developed to make an easy and quick graphic survey of flux and/or power data calculated with SCALE modules or other core calculation or shielding codes. The basic plot functions it can perform are one- and two-dimensional plots of flux or power distributions and flux energy spectra. More specifically it can produce plots of the flux distribution in a one-dimensional geometry for one or more energy groups in one figure. It can also plot the flux distribution along a cut through a two- or three-dimensional geometry along one of the coordinate axes and it can plot a two-dimensional view of the flux distribution of a two-dimensional geometry or of a plane cut through a three-dimensional geometry. The same can be done for the power distribution in a system. Furthermore SCALPLO can plot the particle flux spectrum as a function of energy, either as group fluxes or as group fluxes per unit energy or per unit lethargy. (orig./HP).

  1. The ORNL Modulating Heat Pump Design Tool User's Guide

    Energy Technology Data Exchange (ETDEWEB)

    Rice, C.K.

    2001-06-01

    The ORNL Modulating Heat Pump Design Tool consists of a Modulating HPDM (Heat Pump Design Model) and a parametric-analysis (contour-data generating) front-end. Collectively the program is also referred to as MODCON which is in reference to the modulating and the contour data generating capabilities. The program was developed by Oak Ridge National Laboratory for the Department of Energy to provide a publicly-available system design tool for variable- and single-speed heat pumps.

  2. Instant node package module

    CERN Document Server

    Ali, Juzer

    2013-01-01

    Get to grips with a new technology, understand what it is and what it can do for you, and then get to work with the most important features and tasks. A practical exploration of the lifecycle of creating node modules as well as learning all of the top features that npm has to offer.Intended for readers who want to create their first node.js modules. The programming paradigm of JavaScript is not covered so a foundation in these concepts would be beneficial.

  3. Millwright Apprenticeship. Related Training Modules. 8.1-8.5 Turbines.

    Science.gov (United States)

    Lane Community Coll., Eugene, OR.

    This packet, part of the instructional materials for the Oregon apprenticeship program for millwright training, contains five modules covering turbines. The modules provide information on the following topics: types, components, and auxiliaries of steam turbines; operation and maintenance of steam turbines; and gas turbines. Each module consists…

  4. Programming language for computations in the Interkosmos program

    Science.gov (United States)

    Schmidt, K.

    1975-01-01

    The programming system for Intercosmos data processing, based on the structural programming theory, which considers a program as an ordered set of standardized elementary parts, from which the user programs are automatically generated, is described. The programs are comprised of several modules, which are briefly summarized. The general structure of the programming system is presented in a block diagram. A programming control language developed to formulate the problem quickly and completely is presented along with basic symbols which are characteristic of the Intercosmos programming system.

  5. A user's guide to the reactor inventory module NECTAR-RICE

    International Nuclear Information System (INIS)

    Barker, C.D.

    1982-01-01

    The NECTAR environmental computer code has been developed to meet the increasing demand for comprehensive calculations of the radiological consequences of the atmosphere release of radionuclides from a nuclear facility. The code consists of a main control program, library listing/modification routines and five calculational modules. The input data required for the reactor inventory module NECTAR-RICE is described. This data includes facilities for specifying the initial conditions, controlling the irradiation conditions of the fuel and for temporarily modifying library data at different stages of the calculation. The structure of the module is briefly described and three sample cases are given to facilitate understanding of the program's use and program testing. These sample cases demonstrate the three different ways of running the program, namely to calculate actinide inventories only, fission product inventories only or to do a composite actinide and fission product calculation. (author)

  6. Comparative study between output factors obtained in a linear accelerator used for radiosurgery treatments

    International Nuclear Information System (INIS)

    Velázquez Trejo, J.J.; Olive, K.I.; Gutiérrez Castillo, J.G.; Hardy Pérez, A.E.

    2017-01-01

    Purpose: To compare the output factors obtained in a linear accelerator with conical collimators using five models of detectors, through tree different methods: the ratio of detector readings, the “daisy chain” technique (for diodes) and applying the k fclin, fmsr Qclin, Qmsr factors based in the formalism proposed by the IAEA (this one was applied only to tree detectors). Methods: A linear accelerator Varian-iX was employed with BrainLab conical collimators (30 mm to 7.5 mm), the detectors used were: PTW-PinPoint 31016 (×2), PTW-tipo E 60017 (×2), PTW-microLion 31018 (×2), EDGE (Sun-Nuclear), y PTW-Semiflex 31010. For the first three models were analyzed two detectors with different series. The measurements were carried out in water at depth of 1.5 cm and source to surface distance of 98.5 cm. Results: With the readings ratio method, all detectors showed differences from 3.5% to more than 15% in the smallest field sizes, for the diodes the “daisy chain” method did not provide significant corrections. Applying the k fclin, fmsr Qclin, Qmsr Small the detectors PTW60017, PTW31018 and EDGE showed differences of less than 3%. Conclusions: In small fields the readings ratio method could introduce significant errors in the output factor determination. Applying the k fclin, fmsr Qclin, Qmsr proved to be a viable option. [es

  7. Determination of small field synthetic single-crystal diamond detector correction factors for CyberKnife, Leksell Gamma Knife Perfexion and linear accelerator.

    Science.gov (United States)

    Veselsky, T; Novotny, J; Pastykova, V; Koniarova, I

    2017-12-01

    The aim of this study was to determine small field correction factors for a synthetic single-crystal diamond detector (PTW microDiamond) for routine use in clinical dosimetric measurements. Correction factors following small field Alfonso formalism were calculated by comparison of PTW microDiamond measured ratio M Qclin fclin /M Qmsr fmsr with Monte Carlo (MC) based field output factors Ω Qclin,Qmsr fclin,fmsr determined using Dosimetry Diode E or with MC simulation itself. Diode measurements were used for the CyberKnife and Varian Clinac 2100C/D linear accelerator. PTW microDiamond correction factors for Leksell Gamma Knife (LGK) were derived using MC simulated reference values from the manufacturer. PTW microDiamond correction factors for CyberKnife field sizes 25-5 mm were mostly smaller than 1% (except for 2.9% for 5 mm Iris field and 1.4% for 7.5 mm fixed cone field). The correction of 0.1% and 2.0% for 8 mm and 4 mm collimators, respectively, needed to be applied to PTW microDiamond measurements for LGK Perfexion. Finally, PTW microDiamond M Qclin fclin /M Qmsr fmsr for the linear accelerator varied from MC corrected Dosimetry Diode data by less than 0.5% (except for 1 × 1 cm 2 field size with 1.3% deviation). Regarding low resulting correction factor values, the PTW microDiamond detector may be considered an almost ideal tool for relative small field dosimetry in a large variety of stereotactic and radiosurgery treatment devices. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  8. Development of a Burnup Module DECBURN Based on the Krylov Subspace Method

    Energy Technology Data Exchange (ETDEWEB)

    Cho, J. Y.; Kim, K. S.; Shim, H. J.; Song, J. S

    2008-05-15

    This report is to develop a burnup module DECBURN that is essential for the reactor analysis and the assembly homogenization codes to trace the fuel composition change during the core burnup. The developed burnup module solves the burnup equation by the matrix exponential method based on the Krylov Subspace method. The final solution of the matrix exponential is obtained by the matrix scaling and squaring method. To develop DECBURN module, this report includes the followings as: (1) Krylov Subspace Method for Burnup Equation, (2) Manufacturing of the DECBURN module, (3) Library Structure Setup and Library Manufacturing, (4) Examination of the DECBURN module, (5) Implementation to the DeCART code and Verification. DECBURN library includes the decay constants, one-group cross section and the fission yields. Examination of the DECBURN module is performed by manufacturing a driver program, and the results of the DECBURN module is compared with those of the ORIGEN program. Also, the implemented DECBURN module to the DeCART code is applied to the LWR depletion benchmark and a OPR-1000 pin cell problem, and the solutions are compared with the HELIOS code to verify the computational soundness and accuracy. In this process, the criticality calculation method and the predictor-corrector scheme are introduced to the DeCART code for a function of the homogenization code. The examination by a driver program shows that the DECBURN module produces exactly the same solution with the ORIGEN program. DeCART code that equips the DECBURN module produces a compatible solution to the other codes for the LWR depletion benchmark. Also the multiplication factors of the DeCART code for the OPR-1000 pin cell problem agree to the HELIOS code within 100 pcm over the whole burnup steps. The multiplication factors with the criticality calculation are also compatible with the HELIOS code. These results mean that the developed DECBURN module works soundly and produces an accurate solution

  9. PROJECTING PRINCIPLES OF «MATHEMATICAL AND PHYSICAL BASICS IN INFORMATICS» MODULE AS PART OF A UNIVERSAL BACCALAUREATE PROGRAM

    Directory of Open Access Journals (Sweden)

    E. K. Samerkhanova

    2016-01-01

    Full Text Available This article is a presentation of “Mathematical and Physical Basics in Informatics” Module projected as part of universal baccalaureate model realized in Minin State Pedagogical University, Nizhny Novgorod, within the educational program for an extended group of qualifications “Informatics and Calculating Machines”. Module authors defined a strategy for baccalaureates preparation in the field of informational technology, which is realized due to a bunch of principles: education fundamentalization, learning systematization, activity, integration and student-centration. The principle of education fundamentalization requires consolidation of scientific and methodological preparation of students. The principle of learning systematization guarantees formation of students’ holistic ideology. The principle of integration is directed onto qualitative interdisciplinary conversion based on mutual enrichment of knowledge and skills. The principle of activity considers student personality, its formation and growth with respect to practical activity as a special form of psychical activity. The principle of student-centration is displayed as social-humanistic purpose of the educational process.

  10. Using Instructional Design, Analyze, Design, Develop, Implement, and Evaluate, to Develop e-Learning Modules to Disseminate Supported Employment for Community Behavioral Health Treatment Programs in New York State

    Directory of Open Access Journals (Sweden)

    Sapana R. Patel

    2018-05-01

    Full Text Available BackgroundImplementation science lacks a systematic approach to the development of learning strategies for online training in evidence-based practices (EBPs that takes the context of real-world practice into account. The field of instructional design offers ecologically valid and systematic processes to develop learning strategies for workforce development and performance support.ObjectiveThis report describes the application of an instructional design framework—Analyze, Design, Develop, Implement, and Evaluate (ADDIE model—in the development and evaluation of e-learning modules as one strategy among a multifaceted approach to the implementation of individual placement and support (IPS, a model of supported employment for community behavioral health treatment programs, in New York State.MethodsWe applied quantitative and qualitative methods to develop and evaluate three IPS e-learning modules. Throughout the ADDIE process, we conducted formative and summative evaluations and identified determinants of implementation using the Consolidated Framework for Implementation Research (CFIR. Formative evaluations consisted of qualitative feedback received from recipients and providers during early pilot work. The summative evaluation consisted of levels 1 and 2 (reaction to the training, self-reported knowledge, and practice change quantitative and qualitative data and was guided by the Kirkpatrick model for training evaluation.ResultsFormative evaluation with key stakeholders identified a range of learning needs that informed the development of a pilot training program in IPS. Feedback on this pilot training program informed the design document of three e-learning modules on IPS: Introduction to IPS, IPS Job development, and Using the IPS Employment Resource Book. Each module was developed iteratively and provided an assessment of learning needs that informed successive modules. All modules were disseminated and evaluated through a learning

  11. Automation of radiation dosimetry using PTW dosemeter and LabVIEWTM

    International Nuclear Information System (INIS)

    Weiss, C.; Al-Frouh, K.; Anjak, O.

    2011-01-01

    Automation of UNIDOS 'Dosemeter' using personal computer (PC) is discussed in this paper. In order to save time and eliminate human operation errors during the radiation dosimetry, suitable software, using LabVIEW TM graphical programming language, was written to automate and facilitate the processes of measurements, analysis and data storage. The software calculates the calibration factor of the ionization chamber in terms of air kerma or absorbed dose to water according to IAEA dosimetry protocols. It also has the ability to print a calibration certificate. The obtained results using this software are found to be more reliable and flexible than those obtained by manual methods previously employed. Using LabVIEW TM as a development tool is extremely convenient to make things easier when software modifications and improvements are needed.

  12. Validating module network learning algorithms using simulated data.

    Science.gov (United States)

    Michoel, Tom; Maere, Steven; Bonnet, Eric; Joshi, Anagha; Saeys, Yvan; Van den Bulcke, Tim; Van Leemput, Koenraad; van Remortel, Piet; Kuiper, Martin; Marchal, Kathleen; Van de Peer, Yves

    2007-05-03

    In recent years, several authors have used probabilistic graphical models to learn expression modules and their regulatory programs from gene expression data. Despite the demonstrated success of such algorithms in uncovering biologically relevant regulatory relations, further developments in the area are hampered by a lack of tools to compare the performance of alternative module network learning strategies. Here, we demonstrate the use of the synthetic data generator SynTReN for the purpose of testing and comparing module network learning algorithms. We introduce a software package for learning module networks, called LeMoNe, which incorporates a novel strategy for learning regulatory programs. Novelties include the use of a bottom-up Bayesian hierarchical clustering to construct the regulatory programs, and the use of a conditional entropy measure to assign regulators to the regulation program nodes. Using SynTReN data, we test the performance of LeMoNe in a completely controlled situation and assess the effect of the methodological changes we made with respect to an existing software package, namely Genomica. Additionally, we assess the effect of various parameters, such as the size of the data set and the amount of noise, on the inference performance. Overall, application of Genomica and LeMoNe to simulated data sets gave comparable results. However, LeMoNe offers some advantages, one of them being that the learning process is considerably faster for larger data sets. Additionally, we show that the location of the regulators in the LeMoNe regulation programs and their conditional entropy may be used to prioritize regulators for functional validation, and that the combination of the bottom-up clustering strategy with the conditional entropy-based assignment of regulators improves the handling of missing or hidden regulators. We show that data simulators such as SynTReN are very well suited for the purpose of developing, testing and improving module network

  13. Comparative study between output factors obtained in a linear accelerator used for radiosurgery treatments; Estudio comparativo entre factores de campo obtenidos en un acelerador lineal usado para tratamientos con radiocirugía

    Energy Technology Data Exchange (ETDEWEB)

    Velázquez Trejo, J.J.; Olive, K.I.; Gutiérrez Castillo, J.G.; Hardy Pérez, A.E.

    2017-11-01

    Purpose: To compare the output factors obtained in a linear accelerator with conical collimators using five models of detectors, through tree different methods: the ratio of detector readings, the “daisy chain” technique (for diodes) and applying the k fclin, fmsr Qclin, Qmsr factors based in the formalism proposed by the IAEA (this one was applied only to tree detectors). Methods: A linear accelerator Varian-iX was employed with BrainLab conical collimators (30 mm to 7.5 mm), the detectors used were: PTW-PinPoint 31016 (×2), PTW-tipo E 60017 (×2), PTW-microLion 31018 (×2), EDGE (Sun-Nuclear), y PTW-Semiflex 31010. For the first three models were analyzed two detectors with different series. The measurements were carried out in water at depth of 1.5 cm and source to surface distance of 98.5 cm. Results: With the readings ratio method, all detectors showed differences from 3.5% to more than 15% in the smallest field sizes, for the diodes the “daisy chain” method did not provide significant corrections. Applying the k fclin, fmsr Qclin, Qmsr Small the detectors PTW60017, PTW31018 and EDGE showed differences of less than 3%. Conclusions: In small fields the readings ratio method could introduce significant errors in the output factor determination. Applying the k fclin, fmsr Qclin, Qmsr proved to be a viable option. [Spanish] Objetivo: Comparar los factores de campo obtenidos en un acelerador lineal con colimadores cónicos utilizando cinco modelos de detectores, mediante tres métodos distintos: a través del cociente entre lecturas de los detectores, con la técnica “daisy chain” (para diodos) y aplicando los factores k fclin, fmsr Qclin, Qmsr basados en el formalismo propuesto por la IAEA (sólo a tres detectores). Métodos: Se empleó un acelerador lineal Varian-iX con colimadores cónicos BrainLab (30mm a 7.5mm), los detectores utilizados fueron: PTW-PinPoint 31016 (×2), PTW-tipo E 60017 (×2), PTW-microLion 31018 (×2), EDGE (Sun-Nuclear), y PTW

  14. Dosimetric comparison of water phantoms, ion chambers, and data acquisition modes for LINAC characterization

    International Nuclear Information System (INIS)

    Cruz, Wilbert; Narayanasamy, Ganesh; Papanikolaou, Niko; Stathakis, Sotirios

    2015-01-01

    Purpose: In this study a dosimetric comparison utilizing continuous data acquisition and discrete data acquisition is examined using IBA Blue Phantom (IBA Dosimetry, Schwarzenbruck, Germany) and PTW (PTW, Freiberg, Germany) MP3-M water tanks. The tanks were compared according to several factors including set up time, ease of use, and data acquisition times. A tertiary objective is to study the response of several ionization chambers in the two tanks examined. Methods: Measurements made using a Varian 23EX LINAC (Varian Medical Systems, Palo Alto, CA) include PDDs and beam profiles for various field sizes with IBA CC13, PTW Semiflex 31010, PTW Pinpoint N31016, and PTW 31013 ion chambers for photons (6, 18 MV) and electrons (6, 9, 12, 15, and 18 MeV). Radial and transverse profile scans were done at depths of maximum dose, 5 cm, 10 cm, and 20 cm using the same set of tanks and detectors for the photon beams. Radial and transverse profile scans were done at depth of maximum dose for the electron beams on the same tanks and chambers. Data processing and analysis was performed using PTW's MEPHYSTO Navigator software and IBA's OmniPro Accept version 6.6 for the respective water tank systems. Results: PDD values agree to within 1% and dmax to within 1 mm for the PTW MP3-M tank using PTW 31010 and Blue Phantom using IBA CC13 chamber, respectively and larger discrepancy with the PTW PinPoint N31016 chamber at 6 MV. With respect to setup time the PTW MP3-M and IBA Blue phantom tank took about 20 and 40 min, respectively. Scan times were longer by 5–15 min per field size in the PTW MP3-M tank for the square field sizes from 1 cm to 40 cm as compared to the IBA Blue phantom. However, data processing times were higher by 7 min per field size with the IBA system. Conclusions: Tank measurements showed little deviation with the higher energy photons as compared to the lower energy photons with regards to the PDD measurements. Chamber construction as well as tank

  15. Qualification standard for photovoltaic concentrator modules

    Energy Technology Data Exchange (ETDEWEB)

    McConnell, R.; Kurtz, S.; Bottenberg, W. R.; Hammond, R.; Jochums, S. W.; McDanal, A. J.; Roubideaux, D.; Whitaker, C.; Wohlgemuth, J.

    2000-05-05

    The paper describes a proposed qualification standard for photovoltaic concentrator modules. The standard's purpose is to provide stress tests and procedures to identify any component weakness in photovoltaic concentrator modules intended for power generation applications. If no weaknesses are identified during qualification, both the manufacturer and the customer can expect a more reliable product. The qualification test program for the standard includes thermal cycles, humidity-freeze cycles, water spray, off-axis beam damage, hail impact, hot-spot endurance, as well as electrical tests for performance, ground continuity, isolation, wet insulation resistance, and bypass diodes. Because concentrator module performance can not be verified using solar simulator and reference cell procedures suitable for flat-plate modules, the standard specifies an outdoor I-V test analysis allowing a performance comparison before and after a test procedure. Two options to this complex analysis are the use of a reference concentrator module for side-by-side outdoor comparison with modules undergoing various tests and a dark I-V performance check.

  16. Leveraging httpModules for Better ASPNET Applications

    CERN Document Server

    Love, Chris

    2008-01-01

    This Wrox Blox explains how to create different types of custom modules for ASP.NET web sites. Custom ASP.NET Modules are a great way to program advanced features to your web site. This Wrox blox discusses the difference between a custom httpModule and the Global.asax file. It also covers the steps in the ASP.NET pipeline. The examples include using a custom module to configure a site's initial settings, a background worker thread, and an IP blocker. Other examples show how to add content to the content being sent to the client, URL Rewriting, and a custom error handler. Table of Contents Intr

  17. ES 1010 software for testing CAMAC modules

    International Nuclear Information System (INIS)

    Ableev, V.G.; Basiladze, S.G.; Zaporozhets, S.A.; Piskunov, N.M.; Ryabtsov, V.D.; Sitnik, I.M.; Strokovskij, E.A.; Sharov, V.I.

    1977-01-01

    Test programs for digital and analog-digital CAMAC modules applied in physical experiments are described. Algorithms were written in FORTRAN-4 language for testing, data acquisition, processing and data control. ASSEMBLER ES 1010 subroutines were used for data acquisition and CAMAC module control. This allowed one to take advantages of a high level language for data processing and display, as well as for achieving an interface with the CAMAC hardware. Software applied enables one to improve considerably adjustment of CAMAC modules and to obtain their operational characteristics

  18. The WIMS-E module W-PROC

    International Nuclear Information System (INIS)

    Roth, M.J.; Harris, D.W.G.

    1980-07-01

    The program W-PROC is a module of the WIMS-E Scheme for neutronics calculations. W-PROC calculates collision probabilities for a system consisting of spherical grains packed in annular geometry, such as the fuel in a high temperature gas cooled reactor. This report describes the modelling approximations made and gives instructions for using the program. (U.K.)

  19. Modern programming language

    Science.gov (United States)

    Feldman, G. H.; Johnson, J. A.

    1980-01-01

    Structural-programming language is especially-tailored for producing assembly language programs for MODCOMP II and IV mini-computes. Modern programming language consists of set of simple and powerful control structures that include sequencing alternative selection, looping, sub-module linking, comment insertion, statement continuation, and compilation termination capabilities.

  20. A user's guide to the atmospheric dispersion module NECTAR-ATMOS

    International Nuclear Information System (INIS)

    Barker, C.D.

    1982-02-01

    The NECTAR environmental computer code has been developed to meet the increasing demand for comprehensive calculations of the radiological consequences due to atmospheric releases of radioactivity. The code contains five calculational modules and this report presents a user's guide to the atmospheric dispersion and individual dose evaluation module NECTAR-ATMOS. The mathematical models employed in NECTAR-ATMOS are briefly described and a complete specification of the input data required for the module is given. The program includes facilities for reading in the source terms, for specifying the atmospheric dispersion parameters, for identifying the dose calculations required and for controlling output from the program to lineprinters and to output utility files. Three sample cases are included in an appendix to demonstrate some of the different ways in which the program may be used and also to provide examples for the prospective user. (author)

  1. Fire!: An Event-Based Science Module. Teacher's Guide. Chemistry and Fire Ecology Module.

    Science.gov (United States)

    Wright, Russell G.

    This book is designed for middle school earth science or physical science teachers to help their students learn scientific literacy through event-based science. Unlike traditional curricula, the event- based earth science module is a student-centered, interdisciplinary, inquiry-oriented program that emphasizes cooperative learning, teamwork,…

  2. An abstract machine model of dynamic module replacement

    OpenAIRE

    Walton, Chris; Kırlı, Dilsun; Gilmore, Stephen

    2000-01-01

    In this paper we define an abstract machine model for the mλ typed intermediate language. This abstract machine is used to give a formal description of the operation of run-time module replacement for the programming language Dynamic ML. The essential technical device which we employ for module replacement is a modification of two-space copying garbage collection. We show how the operation of module replacement could be applied to other garbage-collected languages such as Java.

  3. A proton beam delivery system for conformal therapy and intensity modulated therapy

    International Nuclear Information System (INIS)

    Yu Qingchang

    2001-01-01

    A scattering proton beam delivery system for conformal therapy and intensity modulated therapy is described. The beam is laterally spread out by a dual-ring double scattering system and collimated by a program-controlled multileaf collimator and patient specific fixed collimators. The proton range is adjusted and modulated by a program controlled binary filter and ridge filters

  4. The ORNL Modulating Heat Pump Design Tool -- Mark IV User's Guide

    Energy Technology Data Exchange (ETDEWEB)

    Rice, C.K.

    2001-09-27

    The ORNL Modulating Heat Pump Design Tool consists of a Modulating HPDM (Heat Pump Design Model) and a parametric-analysis (contour-data generating) front-end. Collectively the program is also referred to as MODCON which is in reference to the modulating and the contour data generating capabilities. The program was developed by Oak Ridge National Laboratory for the Department of Energy to provide a publicly-available system design tool for variable- and single-speed heat pumps.

  5. The Efficacy of IRIS "STAR Legacy" Modules under Different Instructional Conditions

    Science.gov (United States)

    Sayeski, Kristin L.; Hamilton-Jones, Bethany; Oh, Susan

    2015-01-01

    The vast majority of special education teacher preparation programs in the United States incorporate the IRIS Center's "STAR Legacy" modules into their coursework. Given the diversity of module content and ways in which the modules are employed, the purpose of this study was to explore the potential mediating effects of instructional…

  6. IFF, Full-Screen Input Menu Generator for FORTRAN Program

    International Nuclear Information System (INIS)

    Seidl, Albert

    1991-01-01

    1 - Description of program or function: The IFF-package contains input modules for use within FORTRAN programs. This package enables the programmer to easily include interactive menu-directed data input (module VTMEN1) and command-word processing (module INPCOM) into a FORTRAN program. 2 - Method of solution: No mathematical operations are performed. 3 - Restrictions on the complexity of the problem: Certain restrictions of use may arise from the dimensioning of arrays. Field lengths are defined via PARAMETER-statements

  7. Software module for geometric product modeling and NC tool path generation

    International Nuclear Information System (INIS)

    Sidorenko, Sofija; Dukovski, Vladimir

    2003-01-01

    The intelligent CAD/CAM system named VIRTUAL MANUFACTURE is created. It is consisted of four intelligent software modules: the module for virtual NC machine creation, the module for geometric product modeling and automatic NC path generation, the module for virtual NC machining and the module for virtual product evaluation. In this paper the second intelligent software module is presented. This module enables feature-based product modeling carried out via automatic saving of the designed product geometric features as knowledge data. The knowledge data are afterwards applied for automatic NC program generation for the designed product NC machining. (Author)

  8. Module Architecture for in Situ Space Laboratories

    Science.gov (United States)

    Sherwood, Brent

    2010-01-01

    The paper analyzes internal outfitting architectures for space exploration laboratory modules. ISS laboratory architecture is examined as a baseline for comparison; applicable insights are derived. Laboratory functional programs are defined for seven planet-surface knowledge domains. Necessary and value-added departures from the ISS architecture standard are defined, and three sectional interior architecture options are assessed for practicality and potential performance. Contemporary guidelines for terrestrial analytical laboratory design are found to be applicable to the in-space functional program. Densepacked racks of system equipment, and high module volume packing ratios, should not be assumed as the default solution for exploration laboratories whose primary activities include un-scriptable investigations and experimentation on the system equipment itself.

  9. An Embedded Reconfigurable Logic Module

    Science.gov (United States)

    Tucker, Jerry H.; Klenke, Robert H.; Shams, Qamar A. (Technical Monitor)

    2002-01-01

    A Miniature Embedded Reconfigurable Computer and Logic (MERCAL) module has been developed and verified. MERCAL was designed to be a general-purpose, universal module that that can provide significant hardware and software resources to meet the requirements of many of today's complex embedded applications. This is accomplished in the MERCAL module by combining a sub credit card size PC in a DIMM form factor with a XILINX Spartan I1 FPGA. The PC has the ability to download program files to the FPGA to configure it for different hardware functions and to transfer data to and from the FPGA via the PC's ISA bus during run time. The MERCAL module combines, in a compact package, the computational power of a 133 MHz PC with up to 150,000 gate equivalents of digital logic that can be reconfigured by software. The general architecture and functionality of the MERCAL hardware and system software are described.

  10. Medical Terminology: Latin Words/Abbreviations; Special Signs and Symbols. Health Occupations Education Module.

    Science.gov (United States)

    Temple Univ., Philadelphia, PA. Div. of Vocational Education.

    This module on medical terminology (using Latin words/abbreviations; special signs and symbols) is one of 17 modules designed for individualized instruction in health occupations education programs at both the secondary and postsecondary levels. This module consists of an introduction to the module topic, a list of resources needed, and three…

  11. Medical Terminology: Using Some Common Prefixes, Suffixes, and Roots. Health Occupations Education Module.

    Science.gov (United States)

    Temple Univ., Philadelphia, PA. Div. of Vocational Education.

    This module on medical terminology (using common prefixes, suffixes, and root words) is one of 17 modules designed for individualized instruction in health occupations education programs at both the secondary and postsecondary levels. This module consists of an introduction to the module topic, a list of resources needed, and three learning…

  12. Analyzing the effectiveness of flare dispensing programs against pulse width modulation seekers using self-organizing maps

    Science.gov (United States)

    Şahingil, Mehmet C.; Aslan, Murat Š.

    2013-10-01

    Infrared guided missile seekers utilizing pulse width modulation in target tracking is one of the threats against air platforms. To be able to achieve a "soft-kill" protection of own platform against these type of threats, one needs to examine carefully the seeker operating principle with its special electronic counter-counter measure (ECCM) capability. One of the cost-effective ways of soft kill protection is to use flare decoys in accordance with an optimized dispensing program. Such an optimization requires a good understanding of the threat seeker, capabilities of the air platform and engagement scenario information between them. Modeling and simulation is very powerful tool to achieve a valuable insight and understand the underlying phenomenology. A careful interpretation of simulation results is crucial to infer valuable conclusions from the data. In such an interpretation there are lots of factors (features) which affect the results. Therefore, powerful statistical tools and pattern recognition algorithms are of special interest in the analysis. In this paper, we show how self-organizing maps (SOMs), which is one of those powerful tools, can be used in analyzing the effectiveness of various flare dispensing programs against a PWM seeker. We perform several Monte Carlo runs for a typical engagement scenario in a MATLAB-based simulation environment. In each run, we randomly change the flare dispending program and obtain corresponding class: "successful" or "unsuccessful", depending on whether the corresponding flare dispensing program deceives the seeker or not, respectively. Then, in the analysis phase, we use SOMs to interpret and visualize the results.

  13. Design optimization of first wall and breeder unit module size for the Indian HCCB blanket module

    Science.gov (United States)

    Deepak, SHARMA; Paritosh, CHAUDHURI

    2018-04-01

    The Indian test blanket module (TBM) program in ITER is one of the major steps in the Indian fusion reactor program for carrying out the R&D activities in the critical areas like design of tritium breeding blankets relevant to future Indian fusion devices (ITER relevant and DEMO). The Indian Lead–Lithium Cooled Ceramic Breeder (LLCB) blanket concept is one of the Indian DEMO relevant TBM, to be tested in ITER as a part of the TBM program. Helium-Cooled Ceramic Breeder (HCCB) is an alternative blanket concept that consists of lithium titanate (Li2TiO3) as ceramic breeder (CB) material in the form of packed pebble beds and beryllium as the neutron multiplier. Specifically, attentions are given to the optimization of first wall coolant channel design and size of breeder unit module considering coolant pressure and thermal loads for the proposed Indian HCCB blanket based on ITER relevant TBM and loading conditions. These analyses will help proceeding further in designing blankets for loads relevant to the future fusion device.

  14. Thermo-mechanical modelling and experimental validation of CLIC prototype module type 0

    CERN Document Server

    Kortelainen, Lauri; Koivurova, Hannu; Riddone, Germana; Österberg, Kenneth

    Micron level stability of the two-meter repetitive modules constituting the two main linacs is one of the most important requirements to achieve the luminosity goal for the Compact Linear Collider. Structural deformations due to thermal loads and related to the RF power dissipated inside the modules affect the alignment of the linacs and therefore the resulting luminosity performance. A CLIC prototype module has been assembled in a dedicated laboratory and a thermal test program has been started in order to study its thermo-mechanical behaviour. This thesis focuses on the finite elements modelling of the first CLIC prototype module 0. The aim of the modelling is to examine the temperature distributions and the resulting deformations of the module in different operating conditions defined in the thermal test program. The theoretical results have been compared to the experimental ones; the comparison shows that the results are in good agreement both for the thermal behaviour of the module and for the resulting ...

  15. Detection of Metallic and Electronic Radar Targets by Acoustic Modulation of Electromagnetic Waves

    Science.gov (United States)

    2017-07-01

    by Acoustic Modulation of Electromagnetic Waves 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Gregory J... Program 13 List of Symbols, Abbreviations, and Acronyms 18 Distribution List 19 Approved for public release; distribution is...4 Fig. 4 Flowchart of wireless experiment to receive acoustically modulated radar waveforms

  16. Optimizing Energy and Modulation Selection in Multi-Resolution Modulation For Wireless Video Broadcast/Multicast

    KAUST Repository

    She, James

    2009-11-01

    Emerging technologies in Broadband Wireless Access (BWA) networks and video coding have enabled high-quality wireless video broadcast/multicast services in metropolitan areas. Joint source-channel coded wireless transmission, especially using hierarchical/superposition coded modulation at the channel, is recognized as an effective and scalable approach to increase the system scalability while tackling the multi-user channel diversity problem. The power allocation and modulation selection problem, however, is subject to a high computational complexity due to the nonlinear formulation and huge solution space. This paper introduces a dynamic programming framework with conditioned parsing, which significantly reduces the search space. The optimized result is further verified with experiments using real video content. The proposed approach effectively serves as a generalized and practical optimization framework that can gauge and optimize a scalable wireless video broadcast/multicast based on multi-resolution modulation in any BWA network.

  17. Optimizing Energy and Modulation Selection in Multi-Resolution Modulation For Wireless Video Broadcast/Multicast

    KAUST Repository

    She, James; Ho, Pin-Han; Shihada, Basem

    2009-01-01

    Emerging technologies in Broadband Wireless Access (BWA) networks and video coding have enabled high-quality wireless video broadcast/multicast services in metropolitan areas. Joint source-channel coded wireless transmission, especially using hierarchical/superposition coded modulation at the channel, is recognized as an effective and scalable approach to increase the system scalability while tackling the multi-user channel diversity problem. The power allocation and modulation selection problem, however, is subject to a high computational complexity due to the nonlinear formulation and huge solution space. This paper introduces a dynamic programming framework with conditioned parsing, which significantly reduces the search space. The optimized result is further verified with experiments using real video content. The proposed approach effectively serves as a generalized and practical optimization framework that can gauge and optimize a scalable wireless video broadcast/multicast based on multi-resolution modulation in any BWA network.

  18. Evaluation of a Digital Game-Based Learning Program for Enhancing Youth Mental Health: A Structural Equation Modeling of the Program Effectiveness.

    Science.gov (United States)

    Huen, Jenny My; Lai, Eliza Sy; Shum, Angie Ky; So, Sam Wk; Chan, Melissa Ky; Wong, Paul Wc; Law, Y W; Yip, Paul Sf

    2016-10-07

    Digital game-based learning (DGBL) makes use of the entertaining power of digital games for educational purposes. Effectiveness assessment of DGBL programs has been underexplored and no attempt has been made to simultaneously model both important components of DGBL: learning attainment (ie, educational purposes of DGBL) and engagement of users (ie, entertaining power of DGBL) in evaluating program effectiveness. This study aimed to describe and evaluate an Internet-based DGBL program, Professor Gooley and the Flame of Mind, which promotes mental health to adolescents in a positive youth development approach. In particular, we investigated whether user engagement in the DGBL program could enhance their attainment on each of the learning constructs per DGBL module and subsequently enhance their mental health as measured by psychological well-being. Users were assessed on their attainment on each learning construct, psychological well-being, and engagement in each of the modules. One structural equation model was constructed for each DGBL module to model the effect of users' engagement and attainment on the learning construct on their psychological well-being. Of the 498 secondary school students that registered and participated from the first module of the DGBL program, 192 completed all 8 modules of the program. Results from structural equation modeling suggested that a higher extent of engagement in the program activities facilitated users' attainment on the learning constructs on most of the modules and in turn enhanced their psychological well-being after controlling for users' initial psychological well-being and initial attainment on the constructs. This study provided evidence that Internet intervention for mental health, implemented with the technologies and digital innovations of DGBL, could enhance youth mental health. Structural equation modeling is a promising approach in evaluating the effectiveness of DGBL programs.

  19. Outreach Education Modules on Space Sciences in Taiwan

    Science.gov (United States)

    Lee, I.-Te; Tiger Liu, Jann-Yeng; Chen, Chao-Yen

    2013-04-01

    The Ionospheric Radio Science Laboratory (IRSL) at Institute of Space Science, National Central University in Taiwan has been conducting a program for public outreach educations on space science by giving lectures, organizing camps, touring exhibits, and experiencing hand-on experiments to elementary school, high school, and college students as well as general public since 1991. The program began with a topic of traveling/living in space, and was followed by space environment, space mission, and space weather monitoring, etc. and a series of course module and experiment (i.e. experiencing activity) module was carried out. For past decadal, the course modules have been developed to cover the space environment of the Sun, interplanetary space, and geospace, as well as the space technology of the rocket, satellite, space shuttle (plane), space station, living in space, observing the Earth from space, and weather observation. Each course module highlights the current status and latest new finding as well as discusses 1-3 key/core issues/concepts and equip with 2-3 activity/experiment modules to make students more easily to understand the topics/issues. Meanwhile, scientific camps are given to lead students a better understanding and interesting on space science. Currently, a visualized image projecting system, Dagik Earth, is developed to demonstrate the scientific results on a sphere together with the course modules. This system will dramatically improve the educational skill and increase interests of participators.

  20. Computer Programs.

    Science.gov (United States)

    Anderson, Tiffoni

    This module provides information on development and use of a Material Safety Data Sheet (MSDS) software program that seeks to link literacy skills education, safety training, and human-centered design. Section 1 discusses the development of the software program that helps workers understand the MSDSs that accompany the chemicals with which they…

  1. Small-Field Dosimetry in A 6 MV Photon Beam Using Alanine and Liquid Ionisation Chamber

    DEFF Research Database (Denmark)

    Zimmermann, S.; Riis, H. L.; Hjelm-Hansen, M.

    2012-01-01

    Purpose/Objective: Dosimetry of small field sizes in MV photon beams is an increasingly important subject, and a generally accepted guideline for clinical measurements is still lacking. The present comparative study was carried out to further investigate the use of alanine and the PTW microLion...... of each field and depth. This dose maximum was measured for each field using a Scanditronix Wellhöfer photon field diode. The same measurements were carried out using a liquid ionchamber, PTW microLion, irradiated by 500 MU. The output of the accelerator was controlled by a PTW semiflex ion chamber...

  2. User Interface for the SMAC Traffic Accident Reconstruction Program

    Directory of Open Access Journals (Sweden)

    Rok Krulec

    2003-11-01

    Full Text Available This paper describes the development of the user interfacefor the traffic accident reconstruction program SMAC. Threebasic modules of software will be presented. Initial parametersinput and visualization, using graphics library for simulation of3D space, which form a graphical user interface, will be explainedin more detail. The modules have been developed usingdifferent technologies and programming approaches to increaseflexibility in further development and to take maximumadvantage of the currently accessible computer hardware, sothat module to module communication is also mentioned.

  3. Modeling of a Stacked Power Module for Parasitic Inductance Extraction

    Science.gov (United States)

    2017-09-15

    ARL-TR-8138 ● SEP 2017 US Army Research Laboratory Modeling of a Stacked Power Module for Parasitic Inductance Extraction by...not return it to the originator. ARL-TR-8138 ● SEP 2017 US Army Research Laboratory Modeling of a Stacked Power Module for... Power Module for Parasitic Inductance Extraction 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Steven Kaplan

  4. Millwright Apprenticeship. Related Training Modules. 7.1-7.9 Boilers.

    Science.gov (United States)

    Lane Community Coll., Eugene, OR.

    This packet, part of the instructional materials for the Oregon apprenticeship program for millwright training, contains nine modules covering boilers. The modules provide information on the following topics: fire and water tube types of boilers, construction, fittings, operation, cleaning, heat recovery systems, instruments and controls, and…

  5. Reviewing a Reading Program: Professional Development Module. Facilitator's Guide

    Science.gov (United States)

    Kosanovich, Marcia; Jordan, Georgia; Arndt, Elissa; VanSciver, Mary; Wahl, Michelle; Rissman, Lila

    2008-01-01

    This "Facilitator's Guide" has been prepared for presenters of the Reviewing a Reading Program professional development training. It is one of three pieces comprising a suite of materials on reviewing reading programs: this "Guide", the "Reviewing a Reading Program Participant's Guide" and the "Reviewing a Reading Program" Professional Development…

  6. Hypertension module: an interactive learning tool in physiology.

    Science.gov (United States)

    Işman, C A; Gülpinar, M A; Kurtel, H; Alican, I; Yeğen, B C

    2003-12-01

    The aim of the present study was to evaluate the strong or weak aspects of an interactive study module introduced during the "Cardiovascular and Respiratory Systems Subject Committee" in the second year of the medical program. Five study groups consisting of 25 students attended two-hour module sessions for six weeks with the same tutor. According to the module assessment questionnaire, the majority of the students assessed the module as excellent or good. The students reported that they had gained not only in knowledge but also in skills development. The general opinion of the students was that both the organization and the implementation of the module met their expectations. Nearly one-half of the students reported that their expectations with regard to the educational environment and the participation of students were fully met. The major weakness in this new educational trial appears to be assessment of the module.

  7. Interactive computer-based training program for radiological workers

    International Nuclear Information System (INIS)

    Trinoskey, P.A.; Camacho, P.I.; Wells, L.

    2000-01-01

    Lawrence Livermore National Laboratory is redesigning its existing Computer-Based Training (CBT) programs for radiological workers. The redesign represents a major effort that is aimed at producing a single highly interactive and flexible CBT program. The new CBT program is designed to address a variety of radiological workers, including researchers, x-ray operators, and individuals working in tritium, uranium, plutonium, and accelerator facilities. The program addresses the diversity of backgrounds found at a national laboratory. The CBT program includes photographs, line drawings and illustrations, sound, video, and simulations, and it allows for easy insertion and replacement of text, graphics, sound, and video. The new design supports timely updates and customization for use at other University of California sites. The CBT program is divided into ten basic modules. Introduction and Lessons Learned, History and Uses, Fundamentals, Background Radiation, Biological Effects of Radiation, Characteristics of Radionuclides, Radiological Controls, Monitoring, Emergency Response, Responsibilities. Some of the main modules features as many as seven or eight submodules. For example, the module on Characteristics of Radionuclides features submodules on common radionuclides, tritium uranium, plutonium, x-ray machines, E-beam devices, radiographic devices, and accelerators. Required submodules are tailored to an individual's type of work and facility, and they are determined by the answers to an onscreen questionnaire given at the outset of training. Individuals can challenge most individual modules, but certain submodules will be mandatory based on the initial survey. For example, individuals working in the uranium facility will be required to complete the submodule on 'History and Uses of Uranium'. However, all other submodules under the main module, 'History and Uses', will be available if selected for preview. For each module, an opportunity is provided for further

  8. The WIMSE-E module W-LED

    International Nuclear Information System (INIS)

    Roth, M.J.

    1992-06-01

    This report describes the WIMS-E edit module W-LED. W-LED sets up a library of cross section and other nuclear data for a set of materials for subsequent use in a whole reactor program such as PANTHER. (author)

  9. Millwright Apprenticeship. Related Training Modules. 1.1-1.8 Safety.

    Science.gov (United States)

    Lane Community Coll., Eugene, OR.

    This packet, part of the instructional materials for the Oregon apprenticeship program for millwright training, contains eight modules covering safety. The modules provide information on the following topics: general safety, hand tool safety, power tool safety, fire safety, hygiene, safety and electricity, types of fire and fire prevention, and…

  10. Scripting Module for the Satellite Orbit Analysis Program (SOAP)

    Science.gov (United States)

    Carnright, Robert; Paget, Jim; Coggi, John; Stodden, David

    2008-01-01

    This add-on module to the SOAP software can perform changes to simulation objects based on the occurrence of specific conditions. This allows the software to encompass simulation response of scheduled or physical events. Users can manipulate objects in the simulation environment under programmatic control. Inputs to the scripting module are Actions, Conditions, and the Script. Actions are arbitrary modifications to constructs such as Platform Objects (i.e. satellites), Sensor Objects (representing instruments or communication links), or Analysis Objects (user-defined logical or numeric variables). Examples of actions include changes to a satellite orbit ( v), changing a sensor-pointing direction, and the manipulation of a numerical expression. Conditions represent the circumstances under which Actions are performed and can be couched in If-Then-Else logic, like performing v at specific times or adding to the spacecraft power only when it is being illuminated by the Sun. The SOAP script represents the entire set of conditions being considered over a specific time interval. The output of the scripting module is a series of events, which are changes to objects at specific times. As the SOAP simulation clock runs forward, the scheduled events are performed. If the user sets the clock back in time, the events within that interval are automatically undone. This script offers an interface for defining scripts where the user does not have to remember the vocabulary of various keywords. Actions can be captured by employing the same user interface that is used to define the objects themselves. Conditions can be set to invoke Actions by selecting them from pull-down lists. Users define the script by selecting from the pool of defined conditions. Many space systems have to react to arbitrary events that can occur from scheduling or from the environment. For example, an instrument may cease to draw power when the area that it is tasked to observe is not in view. The contingency

  11. Alertness Management In Flight Operations: A NASA Education and Training Module

    Science.gov (United States)

    Rosekind, Mark R.; Lebacqz, Victor J.; Gander, Philippa H.; Co, Elizabeth L.; Weldon, Keri J.; Smith, Roy M.; Miller, Donna L.; Gregory, Kevin B.; Statler, Irving C. (Technical Monitor)

    1994-01-01

    Since 1980, the NASA Ames Fatigue Countermeasures Program has been conducting research on sleep, circadian rhythms, and fatigue in a variety of flight operations 1. An original goal of the program was to return the scientific and operational knowledge to the aviation industry. To meet this goal, the NASA Ames Fatigue Countermeasures Program has created an Education and Training Module entitled, "Strategies for Alertness Management in Flight Operations." The Module was designed to meet three objectives: 1) explain the current state of knowledge about the physiological mechanisms underlying fatigue, 2) demonstrate how this knowledge can be applied to improve flight crew sleep, performance, and alertness, and 3) offer countermeasure recommendations. The Module is composed of two components: 1) a 60-minute live presentation provided by a knowledgeable individual and 2) a NASA/FAA Technical Memorandum (TM) that contains the presentation materials and appendices with complementary information. The TM is provided to all individuals attending the live presentation. The Module content is divided into three parts: 1) basic information on sleep, sleepiness, circadian rhythms, fatigue, and how flight operations affect these physiological factors, 2) common misconceptions about sleep, sleepiness, and fatigue, and 3) alertness management strategies. The Module is intended for pilots, management personnel, schedulers, flight attendants, and the many other individuals involved in the aviation system.

  12. Qualification testing of flat-plate photovoltaic modules

    Science.gov (United States)

    Hoffman, A. R.; Griffith, J. S.; Ross, R. G., Jr.

    1982-01-01

    The placement of photovoltaic modules in various applications, in climates and locations throughout the world, results in different degrees and combinations of environmental and electrical stress. Early detection of module reliability deficiencies via laboratory testing is necessary for achieving long, satisfactory field service. This overview paper describes qualification testing techniques being used in the US Department of Energy's flat-plate terrestrial photovoltaic development program in terms of their significance, rationale for specified levels and durations, and test results.

  13. Five Apollo astronauts with Lunar Module at ASVC prior to grand opening

    Science.gov (United States)

    1997-01-01

    Some of the former Apollo program astronauts observe a Lunar Module and Moon mockup during a tour the new Apollo/Saturn V Center (ASVC) at KSC prior to the gala grand opening ceremony for the facility that was held Jan. 8, 1997. The astronauts were invited to participate in the event, which also featured NASA Administrator Dan Goldin and KSC Director Jay Honeycutt. Some of the visiting astonauts were (from left): Apollo 10 Lunar Module Pilot and Apollo 17 Commander Eugene A. Cernan; Apollo 9 Lunar Module Pilot Russell L. Schweikart; Apollo 10 Command Module Pilot and Apollo 16 Commander John W. Young; Apollo 10 Commander Thomas P. Stafford; and Apollo 11 Lunar Module Pilot Edwin E. 'Buzz' Aldrin, Jr. The ASVC also features several other Apollo program spacecraft components, multimedia presentations and a simulated Apollo/Saturn V liftoff. The facility will be a part of the KSC bus tour that embarks from the KSC Visitor Center.

  14. Fastbus diagnostic program (Version 1.1)

    International Nuclear Information System (INIS)

    Acton, P.D.; Clarke, P.E.L.; McKemey, A.K.

    1990-07-01

    The Fastbus Diagnostic Program (FDP) described here is a program designed primarily for module engineering purposes. It provides simple DCL type access to atomic Fastbus operations from the keyboard, without necessitating any lengthy setup of parameters. The commands are designed to cater for the practical needs of an engineer working on, say a prototype module, and requiring fast single line entry, with only a minimum set of required arguments. (author)

  15. A Self-Instructional Course in Student Financial Aid Administration. Module 8: Need Analysis. Second Edition.

    Science.gov (United States)

    Washington Consulting Group, Inc., Washington, DC.

    The eighth module in a 17-module self-instructional program on student financial aid administration (designed for novice student financial aid administrators and other personnel) focuses on need analysis. It provides an introduction to the management of federal financial aid programs authorized by the Higher Education Act Title IV. After…

  16. Normal operation and maintenance safety lessons from the ITER US PbLi test blanket module program for a US FNSF and DEMO

    Energy Technology Data Exchange (ETDEWEB)

    Merrill, B.J., E-mail: Brad.Merrill@inl.gov [Fusion Safety Program, Idaho National Laboratory, Idaho Falls, ID (United States); Wong, C.P.C. [General Atomics, San Diego, CA 92186-5608 (United States); Cadwallader, L.C. [Fusion Safety Program, Idaho National Laboratory, Idaho Falls, ID (United States); Abdou, M.; Morley, N.B. [University of California Los Angeles, Los Angeles, CA 90095-1597 (United States)

    2014-10-15

    A leading power reactor breeding blanket candidate for a fusion demonstration power plant (DEMO) being pursued by the US Fusion Community is the Dual Coolant Lead Lithium (DCLL) concept. The safety hazards associated with the DCLL concept as a reactor blanket have been examined in several US design studies. These studies identify the largest radiological hazards as those associated with the dust generation by plasma erosion of plasma blanket module first walls, oxidation of blanket structures at high temperature in air or steam, inventories of tritium bred in or permeating through the ferritic steel structures of the blanket module and blanket support systems, and the {sup 210}Po and {sup 203}Hg produced in the PbLi breeder/coolant. What these studies lack is the scrutiny associated with a licensing review of the DCLL concept. An insight into this process was gained during the US participation in the ITER Test Blanket Module (TBM) Program. In this paper we discuss the lessons learned during this activity and make safety proposals for the design of a Fusion Nuclear Science Facility (FNSF) or a DEMO that employs a lead lithium breeding blanket.

  17. Results of the PRDA 35 qualification tests of the Motorola concentrating photovoltaic module

    Energy Technology Data Exchange (ETDEWEB)

    Pritchard, D.A.

    1981-10-01

    A passively-cooled, Fresnel lens, concentrating photovoltaic module, designed and built by Motorola, Incorporated, was tested to the PRDA 35 specifications. The PRDA 35 module test program is described. Physical, electrical, and thermal characteristics of the module are presented. Module performance is shown using multiple linear regression techniques: some change was measured after environmental exposure. In addition, sample cell assemblies were evaluated for effects of severe environmental conditions. Results presented herein show the module has met the qualification goals.

  18. Post-Lamination Manufacturing Process Automation for Photovoltaic Modules: Final Subcontract Report, April 1998 - April 2002

    Energy Technology Data Exchange (ETDEWEB)

    Nowlan, M. J.; Murach, J. M.; Sutherland, S. F.; Miller, D. C.; Moore, S. B.; Hogan, S. J.

    2002-11-01

    This report describes the automated systems developed for PV module assembly and testing processes after lamination. These processes are applicable to a broad range of module types, including those made with wafer-based and thin-film solar cells. Survey data and input from module manufacturers gathered during site visits were used to define system capabilities and process specifications. Spire completed mechanical, electrical, and software engineering for four automation systems: a module edge trimming system, the SPI-TRIM 350; an edge sealing and framing system, the SPI-FRAMER 350; an integrated module testing system, the SPI-MODULE QA 350; and a module buffer storage system, the SPI-BUFFER 350. A fifth system for junction-box installation, the SPI-BOXER 350, was nearly completed during the program. A new-size solar simulator, the SPI-SUN SIMULATOR 350i, was designed as part of the SPI-MODULE QA 350. This simulator occupies minimal production floor space, and its test area is large enough to handle most production modules. The automated systems developed in this program are designed for integration to create automated production lines.

  19. Dose verification for respiratory-gated volumetric modulated arc therapy

    Energy Technology Data Exchange (ETDEWEB)

    Qian Jianguo; Xing Lei; Liu Wu; Luxton, Gary, E-mail: gluxton@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA 94305 (United States)

    2011-08-07

    A novel commercial medical linac system (TrueBeam(TM), Varian Medical Systems, Palo Alto, CA) allows respiratory-gated volumetric modulated arc therapy (VMAT), a new modality for treating moving tumors with high precision and improved accuracy by allowing for regular motion associated with a patient's breathing during VMAT delivery. The purpose of this work is to adapt a previously-developed dose reconstruction technique to evaluate the fidelity of VMAT treatment during gated delivery under clinic-relevant periodic motion related to patient breathing. A Varian TrueBeam system was used in this study. VMAT plans were created for three patients with lung or pancreas tumors. Conventional 6 and 15 MV beams with flattening filter and high-dose-rate 10 MV beams with no flattening filter were used in these plans. Each patient plan was delivered to a phantom first without gating and then with gating for three simulated respiratory periods (3, 4.5 and 6 s). Using the adapted log-file-based dose reconstruction procedure supplemented with ion chamber array (Seven29(TM), PTW, Freiburg, Germany) measurements, the delivered dose was used to evaluate the fidelity of gated VMAT delivery. Comparison of Seven29 measurements with and without gating showed good agreement with gamma-index passing rates above 99% for 1%/1 mm dose accuracy/distance-to-agreement criteria. With original plans as reference, gamma-index passing rates were 100% for the reconstituted plans (1%/1 mm criteria) and 93.5-100% for gated Seven29 measurements (3%/3 mm criteria). In the presence of leaf error deliberately introduced into the gated delivery of a pancreas patient plan, both dose reconstruction and Seven29 measurement consistently indicated substantial dosimetric differences from the original plan. In summary, a dose reconstruction procedure was demonstrated for evaluating the accuracy of respiratory-gated VMAT delivery. This technique showed that under clinical operation, the TrueBeam system

  20. Quad nanosecond delay module

    International Nuclear Information System (INIS)

    McDonald, R.J.; Hunter, J.B.; Wozniak, G.J.

    1986-04-01

    Four nanosecond (ns) delay units have been designed to fit in a single-width NIM module. This module is particularly suited for use in conjunction with quad constant fraction timing discriminators (CFTDs) since it has four delay units that can be placed adjacent to the four units of the CFTD. A series of different length cables connected via DIP toggle switches provide delays of 0.60 ns in 4 ns increments. Thus, the CFTD delay can be optimized for pulses of different rise times from approx.10-100 ns. Design work for the PC board and silkscreening of the front panel were done with the MacDraw program on the Apple Mackintosh computer and printed with the Lasewriter printer. 6 refs

  1. Photovoltaic module certification/laboratory accreditation criteria development

    Energy Technology Data Exchange (ETDEWEB)

    Osterwald, C.R. [National Renewable Energy Lab., Golden, CO (United States); Hammond, R.L.; Wood, B.D.; Backus, C.E.; Sears, R.L. [Arizona State Univ., Tempe, AZ (United States); Zerlaut, G.A. [SC-International Inc., Phoenix, AZ (United States); D`Aiello, R.V. [RD Associates, Tempe, AZ (United States)

    1995-04-01

    This document provides an overview of the structure and function of typical product certification/laboratory accreditation programs. The overview is followed by a model program which could serve as the basis for a photovoltaic (PV) module certification/laboratory accreditation program. The model covers quality assurance procedures for the testing laboratory and manufacturer, third-party certification and labeling, and testing requirements (performance and reliability). A 30-member Criteria Development Committee was established to guide, review, and reach a majority consensus regarding criteria for a PV certification/laboratory accreditation program. Committee members represented PV manufacturers, end users, standards and codes organizations, and testing laboratories.

  2. The collision probability modules of WIMS-E

    International Nuclear Information System (INIS)

    Roth, M.J.

    1985-04-01

    This report describes how flat source first flight collision probabilities are calculated and used in the WIMS-E modular program. It includes a description of the input to the modules W-FLU, W-THES, W-PIP, W-PERS and W-MERGE. Input to other collision probability modules are described in separate reports. WIMS-E is capable of calculating collision probabilities in a wide variety of geometries, some of them quite complicated. It can also use them for a variety of purposes. (author)

  3. Module theory, extending modules and generalizations

    CERN Document Server

    Tercan, Adnan

    2016-01-01

    The main focus of this monograph is to offer a comprehensive presentation of known and new results on various generalizations of CS-modules and CS-rings. Extending (or CS) modules are generalizations of injective (and also semisimple or uniform) modules. While the theory of CS-modules is well documented in monographs and textbooks, results on generalized forms of the CS property as well as dual notions are far less present in the literature. With their work the authors provide a solid background to module theory, accessible to anyone familiar with basic abstract algebra. The focus of the book is on direct sums of CS-modules and classes of modules related to CS-modules, such as relative (injective) ejective modules, (quasi) continuous modules, and lifting modules. In particular, matrix CS-rings are studied and clear proofs of fundamental decomposition results on CS-modules over commutative domains are given, thus complementing existing monographs in this area. Open problems round out the work and establish the...

  4. Penumbra measurements of BeamModulatorTM multi leaf collimator

    International Nuclear Information System (INIS)

    Lu Xiaoguang; Wang Yunlai; Huo Xiaoqing; Sha Xiangyan; Miao Xiongfei

    2010-01-01

    Objective: To evaluate the penumbra of a new multileaf collimator equipped with Elekta Synergy accelerator. Methods: The penumbra were derived from beam profiles measured in air and water using PinPoint ion chamber with PTW MP3 water phantom. Variations of penumbra with X-ray beam energy, depth in water, and leaf position were investigated. Results: The penumbra in air for 6 MV X-ray was 2 mm less than that at depth of maximal dose in water. The penumbra of leaf side was 1 mm less than that of the leaf end. The penumbra had close relationship with beam energy, depth in water and leaf position. penumbra increased with beam quality and water depth. The leaf position had great influence on the penumbra. Conclusions: The penumbra of the multileaf collimator is related to its original design and radiation delivery technique. Special considerations should be taken into during treatment planning. Regular measurement should be performed to guarantee the delivery quality. (authors)

  5. Payroll. Computer Module for Use in a Mathematics Laboratory Setting.

    Science.gov (United States)

    Barker, Karen; And Others

    This is one of a series of computer modules designed for use by secondary students who have access to a computer. The module, designed to help students understand various aspects of payroll calculation, includes a statement of objectives, a time schedule, a list of materials, an outline for each section, and several computer programs. (MK)

  6. A user's guide to the inhalation and external radiation collective dose module NECTAR-POPDOS

    International Nuclear Information System (INIS)

    Merlin, J.H.

    1982-02-01

    NECTAR-POPDOS is a module of the computer program NECTAR, which has been written in modular form to evaluate radioactive releases from nuclear fuel, their dispersion in the environment and the consequent individual and collective doses to man. The NECTAR-POPDOS module may be used to evaluate external and inhalation collective doses to any specified area of Great Britain, either to the total population or to any one of six age groups, using population data from the 1971 UK census. If a dose-risk function is defined, the module may be used to assess population health effects or for optimisation studies. The module is based on the stand-alone program POPDOS2, and is written in Fortran IV. The input data to the module is described and the module's limitations and sources of inaccuracy are discussed. Appendices to the report contain the necessary Job Control Language for running NECTAR, a list of NECTAR-POPDOS subroutines, and the input and output of two sample NECTAR-POPDOS cases. (author)

  7. Agricultural countermeasure program - AGRICP: food and dose module in ARGOS- accident reporting and Guidance Operational System

    International Nuclear Information System (INIS)

    Calábria, Jaqueline A.A.; Morais, Gustavo F.

    2017-01-01

    Nuclear or radiological emergencies can affect food, feed and commodities grown. The regulatory bodies has a role in the post-accident phase instructing the population regarding the consumption of agricultural products, monitoring and recovering the contaminated areas and disposing the generated waste. To deal with nuclear/radiological emergencies, in the end of 2007, Brazil took part of the ARGOS consortium. ARGOS is a software used for support the Preparedness and Response of a nuclear emergency. Specifically for use during the recovery phase, ARGOS has a module called AgriCP (Agricultural Countermeasure Program). This functionality was add to the version 9.0 of ARGOS, in 2012, replacing FMD (Food and Dose Module) model. AgriCP can be very useful in the post-accident phasing, helping to planning the actions that must be taken, saving human and budged resources. However, most of the parameters used by default for the model are specific for Central Europe and must be adapted to the Brazilian characteristics. In this paper the basic functionalities of AgriCP are presented and a general view of the issues to be addressed while implementing AgriCP for the Brazilian case is given. Besides the lack of specific parameters for the Brazilian reality, the definition of the area to be considering for intervention in an accident, taking into account the very complex meteorological characteristic of the Brazilian NPPs (nuclear power plants) site, are some of the matters of concern. (author)

  8. Agricultural countermeasure program - AGRICP: food and dose module in ARGOS- accident reporting and Guidance Operational System

    Energy Technology Data Exchange (ETDEWEB)

    Calábria, Jaqueline A.A.; Morais, Gustavo F., E-mail: jaqueline.calabria@cnen.gov.br, E-mail: gustavo.morais@cnen.gov.br [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2017-11-01

    Nuclear or radiological emergencies can affect food, feed and commodities grown. The regulatory bodies has a role in the post-accident phase instructing the population regarding the consumption of agricultural products, monitoring and recovering the contaminated areas and disposing the generated waste. To deal with nuclear/radiological emergencies, in the end of 2007, Brazil took part of the ARGOS consortium. ARGOS is a software used for support the Preparedness and Response of a nuclear emergency. Specifically for use during the recovery phase, ARGOS has a module called AgriCP (Agricultural Countermeasure Program). This functionality was add to the version 9.0 of ARGOS, in 2012, replacing FMD (Food and Dose Module) model. AgriCP can be very useful in the post-accident phasing, helping to planning the actions that must be taken, saving human and budged resources. However, most of the parameters used by default for the model are specific for Central Europe and must be adapted to the Brazilian characteristics. In this paper the basic functionalities of AgriCP are presented and a general view of the issues to be addressed while implementing AgriCP for the Brazilian case is given. Besides the lack of specific parameters for the Brazilian reality, the definition of the area to be considering for intervention in an accident, taking into account the very complex meteorological characteristic of the Brazilian NPPs (nuclear power plants) site, are some of the matters of concern. (author)

  9. The EVEREST Doping Profile Module. Version 4

    International Nuclear Information System (INIS)

    Ashby, J.; Fowler, R.; Greenough, C.

    1998-01-01

    In this report we describe the EVEREST Doping Module which forms part of the EVEREST suite of programs. The doping module is responsible for generating a neutral file which gives the acceptor and donor densities at each node the device mesh. The neutral file also contains details of the functions used to generate the doping as mesh refinement in the solver requires this. Commands allow the definition of background doping, regions of uniform doping, non-uniform doping relating to windows found in the Geometry neutral file and a user-programmable FORTRAN subroutine which computes doping concentrations as a function of position. The EVEREST suite is one of the products of the ESPRIT project EVEREST (ESPRIT 962E-17, Three-Dimensional Algorithms for a Robust and Efficient Semiconductor Simulator with Parameter Extraction). EVEREST was a four-year project supported by the European Community under the European Strategic Program for Research in Information Technology (ESPRIT) which is investigating suitable algorithms for the analysis of semiconductor devices in three dimensions, and developing software implementing the most effective of those algorithms. The original authors of the Doping Module were G.A. Duffett and M.S. Towers of University College, Swansea. (author)

  10. A memory module for experimental data handling

    Science.gov (United States)

    De Blois, J.

    1985-02-01

    A compact CAMAC memory module for experimental data handling was developed to eliminate the need of direct memory access in computer controlled measurements. When using autonomous controllers it also makes measurements more independent of the program and enlarges the available space for programs in the memory of the micro-computer. The memory module has three modes of operation: an increment-, a list- and a fifo mode. This is achieved by connecting the main parts, being: the memory (MEM), the fifo buffer (FIFO), the address buffer (BUF), two counters (AUX and ADDR) and a readout register (ROR), by an internal 24-bit databus. The time needed for databus operations is 1 μs, for measuring cycles as well as for CAMAC cycles. The FIFO provides temporary data storage during CAMAC cycles and separates the memory part from the application part. The memory is variable from 1 to 64K (24 bits) by using different types of memory chips. The application part, which forms 1/3 of the module, will be specially designed for each application and is added to the memory chian internal connector. The memory unit will be used in Mössbauer experiments and in thermal neutron scattering experiments.

  11. Self-initialization module for the RELAP4/MOD7 program

    International Nuclear Information System (INIS)

    Behling, S.R.; Burgess, C.H.; Johnsen, G.W.

    1979-01-01

    An automated self-initialization option has been developed and implemented into the RELAP4/MOD7 computer code. With this new feature, pressurized water reactors or similar models may be initialized to steady state conditions with minimal user-supplied input data. Previously, the analyst (user) had to hand compute all pressures and temperatures in conjunction with several iterative computer runs. Two semi-independent functions, pressure balancing and thermal balancing, comprise the self-initialization module. The user supplies input data specifying a reference pressure and temperature and associated locations. Control volume pressures and temperatures are computed consistent with the nodalization, geometry, total power, and mass flow rates specified. Verification has been accomplished by performing transient calculations on system models and observing the persistence of stable operating conditions. Preparation of input data for the self-initialization module seldom requires more than several man-hours. Computing time required on a CDC 7600 computer to complete the self-initialization process is typically less than 30 seconds

  12. The Hands-On Optics Project: a demonstration of module 3-magnificent magnifications

    Science.gov (United States)

    Pompea, Stephen M.; Sparks, Robert T.; Walker, Constance E.

    2014-07-01

    The Hands-On Optics project offers an example of a set of instructional modules that foster active prolonged engagement. Developed by SPIE, OSA, and NOAO through funding from the U.S. National Science Foundation, the modules were originally designed for afterschool settings and museums. However, because they were based on national standards in mathematics, science, and technology, they were easily adapted for use in classrooms. The philosophy and implementation strategies of the six modules will be described as well as lessons learned in training educators. The modules were implementing with the help of optics industry professionals who served as expert volunteers to assist educators. A key element of the modules was that they were developed around an understanding of optics misconceptions and used culminating activities in each module as a form of authentic assessment. Thus student achievement could be measured by evaluating the actual product created by each student in applying key concepts, tools, and applications together at the end of each module. The program used a progression of disciplinary core concepts to build an integrated sequence and crosscutting ideas and practices to infuse the principles of the modern electro-optical field into the modules. Whenever possible, students were encouraged to experiment and to create, and to pursue inquiry-based approaches. The result was a program that had high appeal to regular as well as gifted students.

  13. Dosimetry of cone-defined stereotactic radiosurgery fields with a commercial synthetic diamond detector.

    Science.gov (United States)

    Morales, Johnny E; Crowe, Scott B; Hill, Robin; Freeman, Nigel; Trapp, J V

    2014-11-01

    Small field x-ray beam dosimetry is difficult due to lack of lateral electronic equilibrium, source occlusion, high dose gradients, and detector volume averaging. Currently, there is no single definitive detector recommended for small field dosimetry. The objective of this work was to evaluate the performance of a new commercial synthetic diamond detector, namely, the PTW 60019 microDiamond, for the dosimetry of small x-ray fields as used in stereotactic radiosurgery (SRS). Small field sizes were defined by BrainLAB circular cones (4-30 mm diameter) on a Novalis Trilogy linear accelerator and using the 6 MV SRS x-ray beam mode for all measurements. Percentage depth doses (PDDs) were measured and compared to an IBA SFD and a PTW 60012 E diode. Cross profiles were measured and compared to an IBA SFD diode. Field factors, ΩQclin,Qmsr (fclin,fmsr) , were calculated by Monte Carlo methods using BEAMnrc and correction factors, kQclin,Qmsr (fclin,fmsr) , were derived for the PTW 60019 microDiamond detector. For the small fields of 4-30 mm diameter, there were dose differences in the PDDs of up to 1.5% when compared to an IBA SFD and PTW 60012 E diode detector. For the cross profile measurements the penumbra values varied, depending upon the orientation of the detector. The field factors, ΩQclin,Qmsr (fclin,fmsr) , were calculated for these field diameters at a depth of 1.4 cm in water and they were within 2.7% of published values for a similar linear accelerator. The corrections factors, kQclin,Qmsr (fclin,fmsr) , were derived for the PTW 60019 microDiamond detector. The authors conclude that the new PTW 60019 microDiamond detector is generally suitable for relative dosimetry in small 6 MV SRS beams for a Novalis Trilogy linear equipped with circular cones.

  14. Permit to Work System Conformity Analysis based on the System Standard Criteria in an Oil and Gas Extraction Company

    Directory of Open Access Journals (Sweden)

    A. Ghahramani

    2007-04-01

    Full Text Available Background and Aims   Permit to work (PTW system as an operational control methods, is an accepted system for control of maintenance activities hazards in chemical industries. The main objective of this study was degree of conformity analysis between existing situation of PTW system and audit criteria.     Methods   In this cross - sectional study, PTW system was audited in an oil and gas extracting   industry by checklist.     Results   Major nonconformities include outdating of system legal and regulation, non existence of permit for majority of dangerous activities, unidentified training needs, incomplete  identification and risk assessment of maintenance hazards before doing them, unspecified   inspection and survey frequencies during works and nonexistence of scheduled auditing for the system.     Conclusion   PTW audit results showed that there is a noticeable gap between audit criteria and  audit evidences. So that the examined system had nonconformities in all of the checklist sections; system, training and competency, permit, coordination and monitoring.  

  15. General Conformity Training Module 2.5: Proactive Role for Federal Agencies

    Science.gov (United States)

    Module 2.5 explains how taking a proactive role will allow a federal agency to more effectively participate in newly promulgated programs under the General Conformity Regulations, such as the emission reduction credits and the emission budgets programs.

  16. Cross software for microprocessor program development at CERN

    International Nuclear Information System (INIS)

    Eicken, H. von; Montuelle, J.; Willers, I.; Blake, J.

    1981-01-01

    Programs for a variety of microprocessors (including Intel 8080; Motorola 6800 and 6809 and 68000; and Texas Instruments 9900) can be prepared on different host computers (such as IBM 370, CDC 6000, and Nord 10) using portable programs developed at CERN. The range of cross software consists of: an assembler for each target microprocessor, a single linkage editor, a single object module librarian, and a variety of pre-loaders which convert object modules from CERN's format (CUFOM) into manufacturers' formats. The programs are written in BCPL and PASCAL, programming languages which are available on a wide range of computers. (orig.)

  17. Progress on the gyrocon deflection-modulated amplifier

    International Nuclear Information System (INIS)

    Tallerico, P.J.

    1982-01-01

    The gyrocon is a high-power deflection-modulated amplifier that can have excellent spatial bunching and, hence, high dc-to-rf conversion efficiency. A program to design and build a prototype amplifier at 450 MHz is discussed. Peak powers of 150 kW and conversion efficiencies of 23% have been measured; the testing program is being pursued to improve this performance. Some possible mechanisms for the difference between the experimental and calculated performance are discussed

  18. A new Implementation of the multi-channel analysis in the dosimetry through radiochromic films; Una nueva implementacion del analisis multicanal en la dosimetria mediante peliculas radiocromicas

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Rodriguez, C.; Martin Martin, G.; Bermudez Luna, R.; Lopez Fernandez, A.; Torres Olombrada, M. V. de; Garcia Canibano, T.; Caballero Guerra, P.

    2013-07-01

    The objectives of this study are to implement multi-channel analysis algorithm using open source tools, extend the application of the same to a scanner other than the supported by Micke, generate maps of dose absorbed in compatible format with the PTW Verisoft quality control program and to quantify the improvement in the results of the gamma index as to what would be obtained by applying a conventional single-channel analysis. (Author)

  19. Automation of program model developing for complex structure control objects

    International Nuclear Information System (INIS)

    Ivanov, A.P.; Sizova, T.B.; Mikhejkina, N.D.; Sankovskij, G.A.; Tyufyagin, A.N.

    1991-01-01

    A brief description of software for automated developing the models of integrating modular programming system, program module generator and program module library providing thermal-hydraulic calcualtion of process dynamics in power unit equipment components and on-line control system operation simulation is given. Technical recommendations for model development are based on experience in creation of concrete models of NPP power units. 8 refs., 1 tab., 4 figs

  20. Irreducible Specht modules are signed Young modules

    OpenAIRE

    Hemmer, David J.

    2005-01-01

    Recently Donkin defined signed Young modules as a simultaneous generalization of Young and twisted Young modules for the symmetric group. We show that in odd characteristic, if a Specht module $S^\\lambda$ is irreducible, then $S^\\lambda$ is a signed Young module. Thus the set of irreducible Specht modules coincides with the set of irreducible signed Young modules. This provides evidence for our conjecture that the signed Young modules are precisely the class of indecomposable self-dual module...

  1. Implementation of large area CMOS image sensor module using the precision align inspection

    International Nuclear Information System (INIS)

    Kim, Byoung Wook; Kim, Toung Ju; Ryu, Cheol Woo; Lee, Kyung Yong; Kim, Jin Soo; Kim, Myung Soo; Cho, Gyu Seong

    2014-01-01

    This paper describes a large area CMOS image sensor module Implementation using the precision align inspection program. This work is needed because wafer cutting system does not always have high precision. The program check more than 8 point of sensor edges and align sensors with moving table. The size of a 2×1 butted CMOS image sensor module which except for the size of PCB is 170 mm×170 mm. And the pixel size is 55 μm×55 μm and the number of pixels is 3,072×3,072. The gap between the two CMOS image sensor module was arranged in less than one pixel size

  2. Implementation of large area CMOS image sensor module using the precision align inspection

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Wook; Kim, Toung Ju; Ryu, Cheol Woo [Radiation Imaging Technology Center, JBTP, Iksan (Korea, Republic of); Lee, Kyung Yong; Kim, Jin Soo [Nano Sol-Tech INC., Iksan (Korea, Republic of); Kim, Myung Soo; Cho, Gyu Seong [Dept. of Nuclear and Quantum Engineering, KAIST, Daejeon (Korea, Republic of)

    2014-12-15

    This paper describes a large area CMOS image sensor module Implementation using the precision align inspection program. This work is needed because wafer cutting system does not always have high precision. The program check more than 8 point of sensor edges and align sensors with moving table. The size of a 2×1 butted CMOS image sensor module which except for the size of PCB is 170 mm×170 mm. And the pixel size is 55 μm×55 μm and the number of pixels is 3,072×3,072. The gap between the two CMOS image sensor module was arranged in less than one pixel size.

  3. Fieldcrest Cannon, Inc. Advanced Technical Preparation. Statistical Process Control (SPC). Safety Section: Modules 1-3. Instructor Book.

    Science.gov (United States)

    Averitt, Sallie D.

    These three modules, which were developed for use by instructors in a manufacturing firm's advanced technical preparation program, contain the materials required to present the safety section of the plant's adult-oriented, job-specific competency-based training program. The 3 modules contain 12 lessons on the following topics: lockout/tagout…

  4. Thyratron-PFN, IGBT Hybrid, and Direct Switched Modulator R and D As it Effects Klystron Protection

    International Nuclear Information System (INIS)

    Gold, Saul L

    2000-01-01

    Modulator development is an ongoing program at SLAC. The Stanford Linear Accelerator with its approximately 240 klystrons and modulators operates for 6,000 plus hours a year. This operation gives SLAC an important insight into component and system reliability in the High Voltage environment. The planned NLC is approximately 10 times the size of SLAC and the High Voltage Modulator Klystron systems are one of the largest cost drivers. This paper will contain a brief progress report on the optimized Line Modulator and touch on Solid-State advances, which make Solid State, High Power pulse modulators the wave of the future. Klystron protection remains a critical issue along with modulator reliability, efficiency and cost. Configurations whereby multiple klystrons are paralleled on a single modulator may exacerbate the problem. The majority of this paper will discuss tests at SLAC of klystron arcs on Line-type modulators with single and double klystron loads. This talk may introduce and refer to other talks at this conference and other conferences by National and Foreign Laboratory collaborators and Industry, specifically in relation to DOE SBIR programs

  5. Mechanism to support generic collective communication across a variety of programming models

    Science.gov (United States)

    Almasi, Gheorghe [Ardsley, NY; Dozsa, Gabor [Ardsley, NY; Kumar, Sameer [White Plains, NY

    2011-07-19

    A system and method for supporting collective communications on a plurality of processors that use different parallel programming paradigms, in one aspect, may comprise a schedule defining one or more tasks in a collective operation, an executor that executes the task, a multisend module to perform one or more data transfer functions associated with the tasks, and a connection manager that controls one or more connections and identifies an available connection. The multisend module uses the available connection in performing the one or more data transfer functions. A plurality of processors that use different parallel programming paradigms can use a common implementation of the schedule module, the executor module, the connection manager and the multisend module via a language adaptor specific to a parallel programming paradigm implemented on a processor.

  6. Testing programs for the Multimission Modular Spacecraft

    Science.gov (United States)

    Greenwell, T. J.

    1978-01-01

    The Multimission Modular Spacecraft (MMS) provides a standard spacecraft bus to a user for a variety of space missions ranging from near-earth to synchronous orbits. The present paper describes the philosophy behind the MMS module test program and discusses the implementation of the test program. It is concluded that the MMS module test program provides an effective and comprehensive customer buy-off at the subsystem contractor's plant, is an optimum approach for checkout of the subsystems prior to use for on-orbit servicing in the Shuttle Cargo Bay, and is a cost-effective technique for environmental testing.

  7. A Whooping Cough Education Module for WIC Clients in Utah.

    Science.gov (United States)

    Luthy, Karlen E; Anderson, Alicia; Macintosh, Janelle; Beckstrand, Renea L; Eden, Lacey M; Amy, Ryan; Macintosh, Christopher I

    Clients in the Special Supplemental Nutrition Program for Women, Infants, and Children (WIC) are required to complete education modules quarterly to maintain eligibility. The purposes of this project were to: (1) create a whooping cough vaccination education module for WIC clients; (2) evaluate baseline perceptions of WIC clients on the whooping cough vaccine and disease; and (3) evaluate whooping cough knowledge following completion of the module. A decline in vaccination rates among infants and children using WIC services was reported by a local WIC program director who requested whooping cough vaccination education materials. This quality improvement project included development of a whooping cough education module and evaluation of learning. Learning was evaluated using a pre- and posttest design. Client feedback was solicited via open-ended questions. Quantitative analysis was performed on visual analog-type questions with paired t-tests and a Cohen's d. Content analysis was conducted on open-ended items. The module was designed by a team of vaccination experts and included general definitions, signs and symptoms during the three stages of disease, recommendations to prevent whooping cough, and vaccination recommendations. Learning of users of the module was then evaluated. After using the module, clients indicated they were significantly more likely to vaccinate themselves and their child against whooping cough, and to recommend the vaccination to their family members. The greatest concern of participants about whooping cough was how it affected infants. Participants reported they learned new information on disease seriousness, recognition of symptoms, and treatment options but still requested additional information on the whooping cough disease and vaccine. A whooping cough education module is an effective strategy to improve whooping cough knowledge and promote the whooping cough vaccine.

  8. Modulation of expression of Programmed Death-1 by administration of probiotic Dahi in DMH-induced colorectal carcinogenesis in rats.

    Science.gov (United States)

    Mohania, Dheeraj; Kansal, Vinod K; Kumar, Manoj; Nagpal, Ravinder; Yamashiro, Yuichiro; Marotta, Francesco

    2013-09-01

    Interaction of probiotic bacteria with the host immune system elicits beneficial immune modulating effects. Although, there are many published studies on interaction of probiotics with immune system focusing on activation of immune system by bacterial cell wall through the engagement of Toll-like receptor family; very few studies have focused on molecules involved in the T-cell activation, and not much work has been executed to study the correlation of probiotics and programmed death-1 in colorectal carcinogenesis in animal models. Hence, the present study was carried out to assess the effect of probiotic Dahi on expression of programmed death (PD-1) in colorectum of 1, 2-dimethylhydrazine treated Wistar rats. DMH was injected subcutaneously at the rate of 40 mg/kg body weight per animal twice a week for 2 weeks. A total of 168 male Wistar rats were randomly allocated to seven groups, each group having twenty-four animals. The rats were euthanized at the 8th, 16th and 32nd week of the experiment and examined for the expression of PD-1 in colorectal tissues by immunohistochemical staining. Expression of PD-1 was observed in colorectal tissues of normal and DMH-treated rats. Feeding rats with probiotic Dahi or the treatment with piroxicam decreased the expression of PD-1 in DMH-induced colorectal mucosa, and the combined treatment with probiotic Dahi and piroxicam was significantly more effective in reducing the expression of PD-1. PD-1 expressed independent of carcinogen administration in normal colonic mucosa and may play a role in modulation of immune response in DMH-induced colorectal carcinogenesis. The present study suggests that probiotic Dahi can be used as an effective chemopreventive agent in the management of colorectal cancer.

  9. Development of intelligent interface for simulation execution by module-based simulation system

    International Nuclear Information System (INIS)

    Yoshikawa, Hidekazu; Mizutani, Naoki; Shimoda, Hiroshi; Wakabayashi, Jiro

    1988-01-01

    An intelligent user support for the two phases of simulation execution was newly developed for Module-based Simulation System (MSS). The MSS has been in development as a flexible simulation environment to improve software productivity in complex, large-scale dynamic simulation of nuclear power plant. The AI programing by Smalltalk-80 was applied to materialize the two user-interface programs for (i) semantic diagnosis of the simulation program generated automatically by MSS, and (ii) consultation system by which user can set up consistent numerical input data files necessary for executing a MSS-generated program. Frame theory was utilized in those interface programs to represent the four knowledge bases, which are (i) usage information on module library in MSS and MSS-generated program, and (ii) expertise knowledge on nuclear power plant analysis such as material properties and reactor system configuration. Capabilities of those interface programs were confirmed by some example practice on LMFBR reactor dynamic calculation, and it was demonstrated that the knowledge-based systemization was effective to improve software work environment. (author)

  10. A memory module for experimental data handling

    International Nuclear Information System (INIS)

    Blois, J. de

    1985-01-01

    A compact CAMAC memory module for experimental data handling was developed to eliminate the need of direct memory access in computer controlled measurements. When using autonomous controllers it also makes measurements more independent of the program and enlarges the available space for programs in the memory of the micro-computer. The memory module has three modes of operation: an increment-, a list- and a fifo mode. This is achieved by connecting the main parts, being: the memory (MEM), the fifo buffer (FIFO), the address buffer (BUF), two counters (AUX and ADDR) and a readout register (ROR), by an internal 24-bit databus. The time needed for databus operations is 1 μs, for measuring cycles as well as for CAMAC cycles. The FIFO provides temporary data storage during CAMAC cycles and separates the memory part from the application part. The memory is variable from 1 to 64K (24 bits) by using different types of memory chips. The application part, which forms 1/3 of the module, will be specially designed for each application and is added to the memory by an internal connector. The memory unit will be used in Moessbauer experiments and in thermal neutron scattering experiments. (orig.)

  11. Modules of the SUMMA system for data readout to the oscillograph, digital display devices and digital printing

    International Nuclear Information System (INIS)

    Bushnin, Yu.B.; Denisenko, A.A.; Dunajtsev, A.F.; Rybakov, V.G.; Sytin, A.N.

    1975-01-01

    The modules of the ''Summa'' system are described which allow outputting of information to an oscilloscope, a digital tableau, and a digital printing mechanism; they are: a digital-analog converter, a converter that converts a binary code to a binary-decimal code, a digital display module, a block for outputting to a digital printing mechanism, and a block for stipulating the programs during information outputting. The block diagrams of the modules and the block diagram of the information-outputting programs are presented

  12. Signed Young Modules and Simple Specht Modules

    OpenAIRE

    Danz, Susanne; Lim, Kay Jin

    2015-01-01

    By a result of Hemmer, every simple Specht module of a finite symmetric group over a field of odd characteristic is a signed Young module. While Specht modules are parametrized by partitions, indecomposable signed Young modules are parametrized by certain pairs of partitions. The main result of this article establishes the signed Young module labels of simple Specht modules. Along the way we prove a number of results concerning indecomposable signed Young modules that are of independent inter...

  13. Independent learning modules enhance student performance and understanding of anatomy.

    Science.gov (United States)

    Serrat, Maria A; Dom, Aaron M; Buchanan, James T; Williams, Alison R; Efaw, Morgan L; Richardson, Laura L

    2014-01-01

    Didactic lessons are only one part of the multimodal teaching strategies used in gross anatomy courses today. Increased emphasis is placed on providing more opportunities for students to develop lifelong learning and critical thinking skills during medical training. In a pilot program designed to promote more engaged and independent learning in anatomy, self-study modules were introduced to supplement human gross anatomy instruction at Joan C. Edwards School of Medicine at Marshall University. Modules use three-dimensional constructs to help students understand complex anatomical regions. Resources are self-contained in portable bins and are accessible at any time. Students use modules individually or in groups in a structured self-study format that augments material presented in lecture and laboratory. Pilot outcome data, measured by feedback surveys and examination performance statistics, suggest that the activity may be improving learning in gross anatomy. Positive feedback on both pre- and post-examination surveys showed that students felt the activity helped to increase their understanding of the topic. In concordance with student perception, average examination scores on module-related laboratory and lecture questions were higher in the two years of the pilot program compared with the year before its initiation. Modules can be fabricated on a modest budget using minimal resources, making implementation practical for smaller institutions. Upper level medical students assist in module design and upkeep, enabling continuous opportunities for vertical integration across the curriculum. This resource offers a feasible mechanism for enhancing independent and lifelong learning competencies, which could be a valuable complement to any gross anatomy curriculum. © 2014 American Association of Anatomists.

  14. The Progress of SBIR Supported R and D of Solid State Pulse Modulators

    International Nuclear Information System (INIS)

    Koontz, R

    2004-01-01

    The Small Business Innovative Research (SBIR) grant program funded by the US Department of Energy makes a number of awards each year for R and D in the field of accelerator technology including high power pulse modulators and their components. This paper outlines program requirements, and reviews some of the awards made in the last three years in support of high power modulator systems and solid state switching. A number of award recipients are presenting the results of their SBIR R and D at this workshop

  15. Rational orderliness of study course modules

    Directory of Open Access Journals (Sweden)

    A. S. Domnikov

    2014-01-01

    Full Text Available Modern electronic courses and textbooks are based, as a rule, on the separate educational modules, which are developed and tested in advance and intended for use in various educational situations. Numerous publications of domestic and foreign authors have discussed a task to form a module-based structure of study course. For its solution have been offered various methods of discrete mathematics, the theory of graphs, and artificial intelligence: semantic networks, ontologies, etc. The important problem that has been much less deeply studied is a rational orderliness of the study course modules.In the work this task is set as a problem to search the best linear approximation of the directed graph the tops of which are modules, while the arches are precedence relations between them. The directed graph is considered as a graphical representation of a binary precedence relation, which has been specified using a set of pairs of educational modules. This relation can be presented as a sum of two components of the symmetric and asymmetric sub-relations. The first sub-relation represents the tolerance relation, and the second one is preorder.To solve the task essentially various ways for processing these components must be used. If a sub-relation of the preorder can be transformed into serial structure, for tolerance any attempts of this kind are doomed to failure. Modules belonging to the relation of tolerance are expedient to merge in a separate educational component. The paper offers a mathematical model in which the problem of merging modules is formulated as a problem of discrete mathematical programming.The paper considers the structure of educational modules formed by hypertext references. It is shown that search of the best linear approximation of such structure is reduced to a classical task about the smallest covering in matrix statement.

  16. Modulation improvements in the 201 MHZ RF generators at LAMPF

    International Nuclear Information System (INIS)

    Parsons, W.M.; Lyles, J.T.M.; Harris, H.W.

    1992-01-01

    Radio-frequency generators, operating at 201 MHz, power the first four stages of the Los Alamos Meson Physics Facility (LAMPF) accelerator. Each generator consists of four stages of seriesconnected, vacuum-tube amplifiers. The modulation scheme for each stage is different. The fist amplifier is a grid-modulated tetrode that produces 500 W peak-power. The second amplifier is a drive-modulated tetrode that produces 5 kill peak-power. The third stage is a grid- and plate-modulated tetrode that produces 130 kill peak-power. The last stage is a plate-modulated triode that produces 2.5 MW peak power. A modernization program has been initiated to improve the reliability of each of these stages. The first two stages of each generator are being replaced with a single, drive-modulated, solid-state amplifier. Specifications for the amplifier design, and requirements for integration into the system are presented. The third stage will be converted to a drive-modulated system using the current tetrode. This modification involves the development of a 17-kV, 15-A switching supply to replace the present plate-modulator. Design requirements for this switching supply are presented. The final stage will remain plate-modulated but will contain a new driver unit for the modulator tube

  17. ALGOL geometrical module for reactor and reactor cell calculations in the R-Z geometry with the Monte Carlo method

    International Nuclear Information System (INIS)

    Usikov, D.A.

    1975-01-01

    A description of a geometrical module used in a program of the ARMONT complex of the Monte Carlo calculations is given. The geometrical module is designed to simulate the particle trajectory in the R-Z geometry. The geometrical module follows the particle trajectory from the start point to the next collision or flight-out points. The flight direction at the scattering point is assumed isotropic in the laboratory coordinate system. In the module the angle between the flight direction before and after collision is not determined. The principles for the module construction are presented alongside with the text-module in the ALGOL language. The module is optimumized as to the counting rate and it is rather compact not to cause difficulties due to the translator limitations in common translation with other program blocks based on the use of the Monte Carlo calculations

  18. Perfection of badminton players’ speed-power fitness with the help of training means’ variable modules

    Directory of Open Access Journals (Sweden)

    I.V. Karatnyk

    2016-06-01

    Full Text Available Purpose: to determine effectiveness of badminton players’ speed power fitness program’s perfection at stage of specialized basic training with different variants of training means modules’ combination. Material: in experiment badminton players of 15-17 years’ age (from 1st sports grade to master of sports participated. The sportsmen were divided into three experimental groups (10 persons in each. The trainings were being conducted during 24 weeks by different variants of program. Results: we created different complexes of exercises, combined in three modules (every of each lasted eight week micro-cycles. Every module has more expressed meaningful parts (1 – speed, 2 – power, 3 – jumping. All modules were combined in program of badminton players’ speed power fitness perfection. For every experimental group we worked out distinguishing variant of modules’ combination in program (first variant – 1-2-3 modules; second – 2-3-1; third – 3-1-2. General duration of program was 24 week micro-cycles. Conclusions: we recommended some variants of variable modules’ combination for badminton players’ speed-power fitness perfection. With it, we can regard total influence on the following: speed-power endurance, work with support on own body, quick movements of different body links.

  19. Energy analysis of solar photovoltaic module production in India

    International Nuclear Information System (INIS)

    Prakash, R.; Bansal, N.K.

    1995-01-01

    The objective of this article is to evaluate the energy consumption in solar photovoltaic (SPV) module production in India and examine its implications for large-scale introduction of SPV plants in the country. Data on energy used in SPV production were collected from existing manufacturing facilities in the country. The energy payback period turns out to be approximately 4 years. This is comparable to energy payback periods of similar modules produced internationally. However, if an ambitious program of introducing SPV power production is undertaken to contribute substantially to the power scenario in the country, an annual growth rate beyond 21% will render the program an energy sink rather than an energy source, as borne out by dynamic energy analysis. Policy implications are also discussed in light of this analysis

  20. THE SOFTWARE OF THE ADVANCED MIL-STD-1553B MULTIPLEX DATA BUS TESTER AND INTERFACE MODULE: FEATURES AND IMPLEMENTATION DETAILS

    Directory of Open Access Journals (Sweden)

    Dmitry E. Gouriev

    2018-03-01

    Full Text Available The UEM-MK is a new module of universal device and parametric tester of multiplex data bus, which meets all requirements for testing equipment for use in validation of devices against requirements of GOST R 52070-2003 (the same as MIL-STD-1553B Notice 4. The module can handle work of bus controller, up to 32 remote terminals and bus monitor/analyser simultaneously, can inject errors of all necessary types. In the article the software of the module is described. The software consist of: the driver, the control panel, the self-test program, the program for validation testing of remote terminals (PTOU, the extended function library, integrated environment (program BPOUEM. The latter three components are top-level components for users and software developments. The driver provides a connection with the module. Control panel provides module identification, self-testing and simplest actions on the bus in interactive mode. The PTOU program provides validation testing of remote terminals in accordance with the GOST R 51765-2001 test plan. The BPOUEM program lets users to create their own scenarios for testing and network environment imitation in interactive mode, whereas the extended function library lets the same in a form of application programs. Both these components also let to record and analyse bus traffic. The purpose, features and implementation details of all mentioned software components are described in the article, however, especial attention is paid to extended function library and the BPOUEM program.

  1. Reviewing a Reading Program: Professional Development Module. Participant's Guide

    Science.gov (United States)

    Kosanovich, Marcia; Jordan, Georgia; Arndt, Elissa; Van Sciver, Mary; Wahl, Michelle; Rissman, Lila

    2008-01-01

    The Curriculum and Instructional Projects Team at the Florida Center for Reading Research (FCRR) developed "Guidelines for Reviewing a Reading Program" ("Guidelines") to assist reviewers in determining if a program is consistent with the scientific research on reading. Based on that work, the Center on Instruction Reading Strand developed this…

  2. A Practical Irradiance Model for Bifacial PV Modules: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Marion, Bill; MacAlpine, Sara; Deline, Chris; Asgharzadeh, Amir; Toor, Fatima; Riley, Daniel; Stein, Joshua; Hansen, Clifford

    2017-06-15

    A model, suitable for a row or multiple rows of photovoltaic (PV) modules, is presented for estimating the backside irradiance for bifacial PV modules. The model, which includes the effects of shading by the PV rows, is based on the use of configuration factors (CFs) to determine the fraction of a source of irradiance that is received by the backside of the PV module. Backside irradiances are modeled along the sloped height of the PV module, but assumed not to vary along the length of the PV row. The backside irradiances are corrected for angle-of-incidence losses and may be added to the front side irradiance to determine the total irradiance resource for the PV cell. Model results are compared with the measured backside irradiances for NREL and Sandia PV systems, and with results when using the RADIANCE ray tracing program.

  3. BASIC Instructional Program: System Documentation.

    Science.gov (United States)

    Dageforde, Mary L.

    This report documents the BASIC Instructional Program (BIP), a "hands-on laboratory" that teaches elementary programming in the BASIC language, as implemented in the MAINSAIL language, a machine-independent revision of SAIL which should facilitate implementation of BIP on other computing systems. Eight instructional modules which make up…

  4. A Semantics for Modular General Logic Programs

    NARCIS (Netherlands)

    Etalle, Sandro

    1998-01-01

    Modular programs are built as a combination of separate modules, which may be developed and verified separately. Therefore, in order to reason over such programs, compositionality plays a crucial role: the semantics of the whole program must be obtainable as a simple function from the semantics of

  5. A semantics for modular general logic programs

    NARCIS (Netherlands)

    Etalle, S.

    1998-01-01

    Modular programs are built as a combination of separate modules, which may be developed and verified separately. Therefore, in order to reason over such programs, compositionality plays a crucial role: the semantics of the whole program must be obtainable as a simple function from the semantics of

  6. Photovoltaic module and interlocked stack of photovoltaic modules

    Science.gov (United States)

    Wares, Brian S.

    2014-09-02

    One embodiment relates to an arrangement of photovoltaic modules configured for transportation. The arrangement includes a plurality of photovoltaic modules, each photovoltaic module including a frame. A plurality of individual male alignment features and a plurality of individual female alignment features are included on each frame. Adjacent photovoltaic modules are interlocked by multiple individual male alignment features on a first module of the adjacent photovoltaic modules fitting into and being surrounded by corresponding individual female alignment features on a second module of the adjacent photovoltaic modules. Other embodiments, features and aspects are also disclosed.

  7. A novel linear programming approach to fluence map optimization for intensity modulated radiation therapy treatment planning

    International Nuclear Information System (INIS)

    Romeijn, H Edwin; Ahuja, Ravindra K; Dempsey, James F; Kumar, Arvind; Li, Jonathan G

    2003-01-01

    We present a novel linear programming (LP) based approach for efficiently solving the intensity modulated radiation therapy (IMRT) fluence-map optimization (FMO) problem to global optimality. Our model overcomes the apparent limitations of a linear-programming approach by approximating any convex objective function by a piecewise linear convex function. This approach allows us to retain the flexibility offered by general convex objective functions, while allowing us to formulate the FMO problem as a LP problem. In addition, a novel type of partial-volume constraint that bounds the tail averages of the differential dose-volume histograms of structures is imposed while retaining linearity as an alternative approach to improve dose homogeneity in the target volumes, and to attempt to spare as many critical structures as possible. The goal of this work is to develop a very rapid global optimization approach that finds high quality dose distributions. Implementation of this model has demonstrated excellent results. We found globally optimal solutions for eight 7-beam head-and-neck cases in less than 3 min of computational time on a single processor personal computer without the use of partial-volume constraints. Adding such constraints increased the running times by a factor of 2-3, but improved the sparing of critical structures. All cases demonstrated excellent target coverage (>95%), target homogeneity (<10% overdosing and <7% underdosing) and organ sparing using at least one of the two models

  8. ICPP - a collision probability module for the AUS neutronics code system

    International Nuclear Information System (INIS)

    Robinson, G.S.

    1985-10-01

    The isotropic collision probability program (ICPP) is a module of the AUS neutronics code system which calculates first flight collision probabilities for neutrons in one-dimensional geometries and in clusters of rods. Neutron sources, including scattering, are assumed to be isotropic and to be spatially flat within each mesh interval. The module solves the multigroup collision probability equations for eigenvalue or fixed source problems

  9. Students' guide to program design

    CERN Document Server

    Robertson, Lesley Anne

    1992-01-01

    Students' Guide to Program Design is a textbook on program design. This textbook approaches program design by using structures programming techniques and pseudocode to develop a solution algorithm. Divided into 10 chapters, the book begins with a basic explanation of structured programming techniques, top-down development, and modular design. This discussion is followed by detailed concepts of the syntax of pseudocode; methods of defining the problem; the application of basic control structures in the development of the solution algorithm; desk checking techniques; hierarchy charts; and module

  10. Weyl modules, demazure modules, KR-modules, crystals, fusion products and limit constructions

    OpenAIRE

    Fourier, G.; Littelmann, P.

    2007-01-01

    We study finite dimensional representations of current algebras, loop algebras and their quantized versions. For the current algebra of a simple Lie algebra of type {\\tt ADE}, we show that Kirillov-Reshetikhin modules and Weyl modules are in fact all Demazure modules. As a consequence one obtains an elementary proof of the dimension formula for Weyl modules for the current and the loop algebra. Further, we show that the crystals of the Weyl and the Demazure module are the same up to some addi...

  11. LBM program at the LOTUS facility

    International Nuclear Information System (INIS)

    File, J.; Haldy, P.A.; Jassby, D.L.; Leo, W.R.; Tsang, F.Y.

    1986-01-01

    The Ecole Polytechnique Federale de Lausanne's (EPFL's) LOTUS facility in Lausanne, Switzerland, consists of a point-neutron deuterium-tritium (D-T) source in a shielded room designed specifically for neutronics experiments with fusion blanket modules. In 1985 the Electric Power Research Institute and EPFL initiated an experimental neutron transport program using irradiation of the Lithium Blanket Module (LBM) by the LOTUS neutron source. The principal objectives of this program are: (a) to test the capability of present-day neutron transport codes to predict the neutronic performance, including tritium breeding, of a reactor-representative blanket module in a relatively simple fast-neutron field and (b) to develop and verify the measurement and data processing procedures that will be used eventually with the LBM experiments at the Tokamak Fusion Test Reactor (TFTR) at Princeton Plasma Physics Lab. (PPPL)

  12. Guidance system operations plan for manned CSM earth orbital and lunar missions using program COLOSSUS 3. Section 7: Erasable memory programs

    Science.gov (United States)

    Hamilton, M. H.

    1972-01-01

    Erasable-memory programs designed for guidance computers used in command and lunar modules are presented. The purpose, functional description, assumptions, restrictions, and imitations are given for each program.

  13. Robot Task Commander with Extensible Programming Environment

    Science.gov (United States)

    Hart, Stephen W (Inventor); Yamokoski, John D. (Inventor); Wightman, Brian J (Inventor); Dinh, Duy Paul (Inventor); Gooding, Dustin R (Inventor)

    2014-01-01

    A system for developing distributed robot application-level software includes a robot having an associated control module which controls motion of the robot in response to a commanded task, and a robot task commander (RTC) in networked communication with the control module over a network transport layer (NTL). The RTC includes a script engine(s) and a GUI, with a processor and a centralized library of library blocks constructed from an interpretive computer programming code and having input and output connections. The GUI provides access to a Visual Programming Language (VPL) environment and a text editor. In executing a method, the VPL is opened, a task for the robot is built from the code library blocks, and data is assigned to input and output connections identifying input and output data for each block. A task sequence(s) is sent to the control module(s) over the NTL to command execution of the task.

  14. Improvement of off-axis SABR plan verification results by using adapted dose reconstruction algorithms for the Octavius 4D system.

    Science.gov (United States)

    Jeevanandam, Prakash; Agnew, Christina E; Irvine, Denise M; McGarry, Conor K

    2018-04-01

    Stereotactic ablative body radiotherapy (SABR) for lung patients can be performed with volumetric-modulated arc therapy (VMAT) plans using off-axis target geometry to allow treatment in their CBCT verified position. For patient-specific quality assurance measurements using the PTW Octavius 4D phantom (PTW, Freiburg, Germany) (OCT4D) in conjunction with an Octavius 1000SRS array (OCT1000) (PTW, Freiburg, Germany), repositioning the phantom off-axis is required to ensure the measurement area coincides with the tumor. The aim of this work is to quantify delivery errors using an array repositioned off-axis and evaluate new software which incorporates corrections for off-axis phantom measurements. Dynamic conformal arcs and 25 lung SABR plans were created with the isocenter at the patient midline and the target volume off-axis. Measurements were acquired with an OCT4D phantom in conjunction with a 729 array (PTW, Freiburg, Germany) (OCT729) placed at isocenter. These plans were recalculated and delivered to both the OCT729 and OCT1000 arrays repositioned so that the high-dose region was at the center of the phantom. Comparisons were made using VeriSoft v7.0 (PTW, Freiburg, Germany) and the newly implemented version 7.1 with 2%/2 mm gamma criterion (10% threshold) and results correlated with off-axis distance to the tumor. Average pass rates for VeriSoft v7.0 significantly reduced from 92.7 ± 2.4% to 84.9 ± 4.1% when the phantom was repositioned compared to the isocenter setup for the OCT729. The gamma pass rates significantly decreased the further the phantom was moved off-axis. Significantly higher pass rates were observed for the OCT1000 of 95.7 ± 3.6% and a significant decrease in gamma pass rate with off-axis phantom distance was again observed. In contrast, even with phantom repositioning, the pass rates for analysis with VeriSoft v7.1 were 93.7 ± 2.1% and 99.4 ± 1.1% for OCT729 and OCT1000, respectively. No significant difference in gamma pass rate

  15. Power module for an experimental picosatellite Cubesat type

    Directory of Open Access Journals (Sweden)

    Javier Castro Avellaneda

    2016-06-01

    Full Text Available This article describes a power module for picosatellite following CubeSat standard requirements [1,2,3,13]. The Power Module project is developed in four phases: study, design, implementation and testing. In the study phase of the theoretical framework and preliminary designs made in the Universidad Distrital [4,5] and other CubeSat developed in the world is reviewed, also investigates existing technologies and components in the market and its affordability. The design phase involves analysis of the system and using a computer program designed to generate the necessary hardware. The ultimate goal is to obtain a functional power module and work in space environment conditions in which the picosatellite keep his focus on an application in telemedicine, with a payload that would become the telecommunications system mission.

  16. NASIS data base management system - IBM 360/370 OS MVT implementation. 4: Program design specifications

    Science.gov (United States)

    1973-01-01

    The design specifications for the programs and modules within the NASA Aerospace Safety Information System (NASIS) are presented. The purpose of the design specifications is to standardize the preparation of the specifications and to guide the program design. Each major functional module within the system is a separate entity for documentation purposes. The design specifications contain a description of, and specifications for, all detail processing which occurs in the module. Sub-modules, reference tables, and data sets which are common to several modules are documented separately.

  17. Superstability for Generalized Module Left Derivations and Generalized Module Derivations on a Banach Module (I

    Directory of Open Access Journals (Sweden)

    Rassias JM

    2009-01-01

    Full Text Available We discuss the superstability of generalized module left derivations and generalized module derivations on a Banach module. Let be a Banach algebra and a Banach -module, and . The mappings , and are defined and it is proved that if (resp., is dominated by then is a generalized (resp., linear module- left derivation and is a (resp., linear module- left derivation. It is also shown that if (resp., is dominated by then is a generalized (resp., linear module- derivation and is a (resp., linear module- derivation.

  18. Universal Reconfigurable Translator Module (URTM) Final Report

    Science.gov (United States)

    Leventhal, Edward; Machan, Roman; Jones, Rob

    2009-01-01

    This report describes the Universal Reconfigurable Translation Module, or URTM. The URTM was developed by Sigma Space Corporation for NASA in order to translate specific serial protocols, both logically and physically. At present, the prototype configuration has targeted MIL-STD-1553B (RT and BC), IEEE 1394b (Firewire), and ECSS-E-50-12A (SpaceWire). The objectives of this program were to study the feasibility of a configurable URTM to translate serial link data as might be used in a space-flight mission and to design, develop, document, and deliver an engineering prototype model of the URTM with a path to spaceflight. By simply connecting two of the three Physical Interface Modules (PIM) on either end of the RPTM (Reconfigurable Protocol Translator Module), the URTM then self configures via a library of interface translation functions, thereby allowing the two data links to communicate seamlessly.

  19. BEAMPATH: a program library for beam dynamics simulation in linear accelerators

    International Nuclear Information System (INIS)

    Batygin, Y.K.

    1992-01-01

    A structured programming technique was used to develop software for space charge dominated beams investigation in linear accelerators. The method includes hierarchical program design using program independent modules and a flexible combination of modules to provide a most effective version of structure for every specific case of simulation. A modular program BEAMPATH was developed for 2D and 3D particle-in-cell simulation of beam dynamics in a structure containing RF gaps, radio-frequency quadrupoles (RFQ), multipole lenses, waveguides, bending magnets and solenoids. (author) 5 refs.; 2 figs

  20. Hardware-Assisted System for Program Execution Security of SOC

    Directory of Open Access Journals (Sweden)

    Wang Xiang

    2016-01-01

    Full Text Available With the rapid development of embedded systems, the systems’ security has become more and more important. Most embedded systems are at the risk of series of software attacks, such as buffer overflow attack, Trojan virus. In addition, with the rapid growth in the number of embedded systems and wide application, followed embedded hardware attacks are also increasing. This paper presents a new hardware assisted security mechanism to protect the program’s code and data, monitoring its normal execution. The mechanism mainly monitors three types of information: the start/end address of the program of basic blocks; the lightweight hash value in basic blocks and address of the next basic block. These parameters are extracted through additional tools running on PC. The information will be stored in the security module. During normal program execution, the security module is designed to compare the real-time state of program with the information in the security module. If abnormal, it will trigger the appropriate security response, suspend the program and jump to the specified location. The module has been tested and validated on the SOPC with OR1200 processor. The experimental analysis shows that the proposed mechanism can defence a wide range of common software and physical attacks with low performance penalties and minimal overheads.

  1. Free online otolaryngology educational modules: a pilot study.

    Science.gov (United States)

    Cabrera-Muffly, Cristina; Bryson, Paul C; Sykes, Kevin J; Shnayder, Yelizaveta

    2015-04-01

    Otolaryngology residents need concise, easily accessible modules to expand educational opportunities between surgical cases. These modules should be inexpensive to create and improve learning outcomes. The purpose of this pilot study was to assess whether otolaryngology residents at multiple institutions used online video modules to supplement their studying for the Otolaryngology Training Exam, whether the modules had any effect on their Otolaryngology Training Examination Scores, and to obtain survey feedback about the modules. This randomized trial was conducted in 3 academic departments of otolaryngology in the United States among 37 residents enrolled in 3 otolaryngology residency programs. Residents were randomized into 2 groups, one with access to the educational modules and the other with no access. Otolaryngology training examination scores were obtained from the year prior to the intervention (2012) and the year following module access (2013). Residents with access to the modules were also surveyed to assess use and obtain feedback about the modules. Otolaryngology training examination scores improved significantly from 2012 to 2013 among both residents who had access to the modules and those who did not in the sections of head and neck, laryngology, and sleep medicine. However, scores in the sections of pediatric otolaryngology (8% increase, P = .03), otology (7% increase, P = .02), and facial plastic surgery (10% increase, P = .02) improved from 2012 to 2013 only among residents with access to the modules. All respondents rated the videos as very helpful, with a rating of 4 of 5 on a Likert scale. Online otolaryngology educational modules are an inexpensive way to expand resident learning opportunities. Despite the lack of quantifiable improvement in otolaryngology training examination scores in this study, use of online modules sends a message to otolaryngology residents that their education is a priority; self-study outside the hospital

  2. The development of fast simulation program for marine reactor parameters

    International Nuclear Information System (INIS)

    Chen Zhiyun; Hao Jianli; Chen Wenzhen

    2012-01-01

    Highlights: ► The simplified physical and mathematical models are proposed for a marine reactor system. ► A program is developed with Simulink module and Matlab file. ► The program developed has the merit of easy input preparation, output processing and fast running. ► The program can be used for the fast simulation of marine reactor parameters on the operating field. - Abstract: The fast simulation program for marine reactor parameters is developed based on the Simulink simulating software according to the characteristics of marine reactor with requirement of maneuverability and acute and fast response. The simplified core physical and thermal model, pressurizer model, steam generator model, control rod model, reactivity model and the corresponding Simulink modules are established. The whole program is developed by coupling all the Simulink modules. Two typical transient processes of marine reactor with fast load increase at low power level and load rejection at high power level are adopted to verify the program. The results are compared with those of Relap5/Mod3.2 with good consistency, and the program runs very fast. It is shown that the program is correct and suitable for the fast and accurate simulation of marine reactor parameters on the operating field, which is significant to the marine reactor safe operation.

  3. Acquisition Program Transition Workshops: An Element of the DSMC Program Manager Mission Assistance Capability

    Science.gov (United States)

    2011-10-01

    specific modules as needed. The term “startup” is inclusive of any point in a DoD acquisition program. As noted above, methodology for conducting...Acquisition Sustainment =Decision Point =Milestone Review =Decision Point if PDR is not conducted before Milestone B ProgramA B Initiation) C IOC FOC...start a new program 2.2 Background Conclusions flowing from these observations led the Office of the Secretary of Defense, the De - fense Acquisition

  4. Analysis of interference of QPSK and QDPSK modulation signals by mathematical

    Science.gov (United States)

    Li, Dairuo; Xu, Kai

    2017-03-01

    In today's society, with the rapid development and extensive application of the information technology of the network central station and the integrated information system technology, information plays an important role in the military communication, mastering the information right to the competition Important role, how to protect one's own security, smooth access to and transmission of information, and to maximize the elimination of interference has become an important issue at home and abroad. QPSK modulation and its improved QPSK modulation as the mainstream signal modulation, the most widely used. In this paper, the principle of QPSK and QDPSK modulation and demodulation are introduced in this paper. Then, how to interfere with QPSK modulation signal is analyzed, and the interference of QPSK modulation signal is simulated by Matlab scripting program, which can be used in the next step. And to study the next step of anti-jamming measures provided the basis and preparatory work.

  5. User's manual for the Composite HTGR Analysis Program (CHAP-1)

    International Nuclear Information System (INIS)

    Gilbert, J.S.; Secker, P.A. Jr.; Vigil, J.C.; Wecksung, M.J.; Willcutt, G.J.E. Jr.

    1977-03-01

    CHAP-1 is the first release version of an HTGR overall plant simulation program with both steady-state and transient solution capabilities. It consists of a model-independent systems analysis program and a collection of linked modules, each representing one or more components of the HTGR plant. Detailed instructions on the operation of the code and detailed descriptions of the HTGR model are provided. Information is also provided to allow the user to easily incorporate additional component modules, to modify or replace existing modules, or to incorporate a completely new simulation model into the CHAP systems analysis framework

  6. Technical Note: Experimental determination of the effective point of measurement of two cylindrical ionization chambers in a clinical proton beam

    Energy Technology Data Exchange (ETDEWEB)

    Sugama, Yuya, E-mail: yuya.sugama@gmail.com [Proton Therapy Center, Aizawa Hospital, Nagano 390-0821, Japan and Interdisciplinary Graduate School of Medicine and Engineering, University of Yamanashi, Yamanashi 409-3898 (Japan); Nishio, Teiji [Institute of Biomedical and Health Sciences, Hiroshima University, Hiroshima 734-8551 (Japan); Onishi, Hiroshi [Interdisciplinary Graduate School of Medicine and Engineering, University of Yamanashi, Yamanashi 409-3898 (Japan)

    2015-07-15

    Purpose: IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement of 0.75 times the inner cavity radius (0.75R) for heavy ion beams. Theoretical models by Palmans and by Bhullar and Watchman confirmed this value. However, the experimental results vary from author to author. The purpose of this study is to accurately measure the displacement and explain the past experimental discrepancies. Methods: In this work, we measured the EPOM of cylindrical ionization chambers with high accuracy by comparing the Bragg-peak position obtained with cylindrical ionization chambers (PTW 30013, PTW 31016) to that obtained using a plane-parallel ionization chamber (PTW 34045). Results: The EPOMs of PTW 30013 and 31016 were shifted by 0.92 ± 0.07 R with R = 3.05 mm and 0.90 ± 0.14 R with R = 1.45 mm, respectively, from the reference point toward the source. Conclusions: The EPOMs obtained were greater than the value of 0.75R proposed by the IAEA TRS-398 and the analytical results.

  7. DMLC motion tracking of moving targets for intensity modulated arc therapy treatment

    DEFF Research Database (Denmark)

    Zimmerman, Jens; Korreman, Stine; Persson, Gitte

    2009-01-01

    (DMLC). The aim of this work was to evaluate the dose delivered to moving targets using the RapidArc (Varian Medical Systems, Inc.) technology with and without a DMLC tracking algorithm. MATERIAL AND METHODS: A Varian Clinac iX was equipped with a preclinical RapidArc and a 3D DMLC tracking application......) and state (1). CONCLUSIONS: DMLC tracking together with RapidArc make a feasible combination and is capable of improving the dose distribution delivered to a moving target. It seems to be of importance to minimize noise influencing the tracking, to gain the full benefit from the application........ A motion platform was placed on the couch, with the detectors on top: a PTW seven29 and a Scandidos Delta4. One lung plan and one prostate plan were delivered. Motion was monitored using a Real-time Position Management (RPM) system. Reference measurements were performed for both plans with both detectors...

  8. Perl Modules for Constructing Iterators

    Science.gov (United States)

    Tilmes, Curt

    2009-01-01

    The Iterator Perl Module provides a general-purpose framework for constructing iterator objects within Perl, and a standard API for interacting with those objects. Iterators are an object-oriented design pattern where a description of a series of values is used in a constructor. Subsequent queries can request values in that series. These Perl modules build on the standard Iterator framework and provide iterators for some other types of values. Iterator::DateTime constructs iterators from DateTime objects or Date::Parse descriptions and ICal/RFC 2445 style re-currence descriptions. It supports a variety of input parameters, including a start to the sequence, an end to the sequence, an Ical/RFC 2445 recurrence describing the frequency of the values in the series, and a format description that can refine the presentation manner of the DateTime. Iterator::String constructs iterators from string representations. This module is useful in contexts where the API consists of supplying a string and getting back an iterator where the specific iteration desired is opaque to the caller. It is of particular value to the Iterator::Hash module which provides nested iterations. Iterator::Hash constructs iterators from Perl hashes that can include multiple iterators. The constructed iterators will return all the permutations of the iterations of the hash by nested iteration of embedded iterators. A hash simply includes a set of keys mapped to values. It is a very common data structure used throughout Perl programming. The Iterator:: Hash module allows a hash to include strings defining iterators (parsed and dispatched with Iterator::String) that are used to construct an overall series of hash values.

  9. Static Mapping of Functional Programs: An Example in Signal Processing

    Directory of Open Access Journals (Sweden)

    Jack B. Dennis

    1996-01-01

    Full Text Available Complex signal-processing problems are naturally described by compositions of program modules that process streams of data. In this article we discuss how such compositions may be analyzed and mapped onto multiprocessor computers to effectively exploit the massive parallelism of these applications. The methods are illustrated with an example of signal processing for an optical surveillance problem. Program transformation and analysis are used to construct a program description tree that represents the given computation as an acyclic interconnection of stream-processing modules. Each module may be mapped to a set of threads run on a group of processing elements of a target multiprocessor. Performance is considered for two forms of multiprocessor architecture, one based on conventional DSP technology and the other on a multithreaded-processing element design.

  10. SU-E-T-194: Commissioning of Monaco Treatment Planning System On An Elekta VersaHD Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Narayanasamy, G; Bosse, C; Saenz, D; Cruz, W; Papanikolaou, N; Stathakis, S [University of Texas Health Science Center at San Antonio, TX (United States); Mavroidis, P [University of North Carolina, Chapel Hill, NC (United States)

    2015-06-15

    Purpose: The Monaco treatment planning system (TPS) uses a Monte-Carlo algorithm based dose computation engine to model the photon beams of a linear accelerator. The aim is to perform verification of Monaco TPS beam modeling of a Elekta VersaHD linac with 6MV, 6MV FFF, 10 MV, 10MV FFF, 18MV photon beams and 160 multileaf collimators (MLC) with a projected width of 5-mm at the isocenter. Methods: A series of dosimetric tests were performed to validate Monaco calculated beams including point dose measurement in water with and without heterogeneity and 2-dimensional dose distributions on a Delta4 bi-planar diode dosimeter array (Scandidos, Uppsala, Sweden). 3D conformal beams of different field sizes, source-to-surface distances, wedges, and gantry angles were delivered onto a phantom consisting of several plastic water and Styrofoam slabs. Point dose measurements were verified with a PTW 31013 Semiflex 0.3 cc ionization chamber (PTW, Freiburg, Germany). In addition, 8 step and shoot intensity modulated radiotherapy (IMRT) and volumetric modulated arc radiotherapy (VMAT) beams included in the Monaco TPS commissioning suite were verified against measurements on Delta4 to test and fine tune parameters in the beam model. IMRT verification was computed using gamma analysis with dose difference and distance-to-agreement criteria of 3%/3mm with a dose threshold of 10%. Results: Point dose measurements agreed within 2% in the homogeneous phantom and within 3% in the heterogeneous phantom for all photon energies. IMRT beams yielded a passing percentage of 99.1±1.1% in the gamma analysis which is well above the institutional passing threshold of 90%. Conclusion: Monaco TPS commissioning was successfully performed for all the photon energies on the Elekta VersaHD linac prior to clinical usage.

  11. SU-E-T-194: Commissioning of Monaco Treatment Planning System On An Elekta VersaHD Linear Accelerator

    International Nuclear Information System (INIS)

    Narayanasamy, G; Bosse, C; Saenz, D; Cruz, W; Papanikolaou, N; Stathakis, S; Mavroidis, P

    2015-01-01

    Purpose: The Monaco treatment planning system (TPS) uses a Monte-Carlo algorithm based dose computation engine to model the photon beams of a linear accelerator. The aim is to perform verification of Monaco TPS beam modeling of a Elekta VersaHD linac with 6MV, 6MV FFF, 10 MV, 10MV FFF, 18MV photon beams and 160 multileaf collimators (MLC) with a projected width of 5-mm at the isocenter. Methods: A series of dosimetric tests were performed to validate Monaco calculated beams including point dose measurement in water with and without heterogeneity and 2-dimensional dose distributions on a Delta4 bi-planar diode dosimeter array (Scandidos, Uppsala, Sweden). 3D conformal beams of different field sizes, source-to-surface distances, wedges, and gantry angles were delivered onto a phantom consisting of several plastic water and Styrofoam slabs. Point dose measurements were verified with a PTW 31013 Semiflex 0.3 cc ionization chamber (PTW, Freiburg, Germany). In addition, 8 step and shoot intensity modulated radiotherapy (IMRT) and volumetric modulated arc radiotherapy (VMAT) beams included in the Monaco TPS commissioning suite were verified against measurements on Delta4 to test and fine tune parameters in the beam model. IMRT verification was computed using gamma analysis with dose difference and distance-to-agreement criteria of 3%/3mm with a dose threshold of 10%. Results: Point dose measurements agreed within 2% in the homogeneous phantom and within 3% in the heterogeneous phantom for all photon energies. IMRT beams yielded a passing percentage of 99.1±1.1% in the gamma analysis which is well above the institutional passing threshold of 90%. Conclusion: Monaco TPS commissioning was successfully performed for all the photon energies on the Elekta VersaHD linac prior to clinical usage

  12. Concept of adaptability in space modules.

    Science.gov (United States)

    Cooper, M

    1990-10-01

    The space program is aiming towards the permanent use of space; to build and establish an orbital space station, a Moon base and depart to Mars and beyond. We must look after the total independency from the Earth's natural resources and work in the design of a modular space base in which each module is capable of duplicating one natural process, and that all these modules in combination take us to conceive a space base capable of sustaining life. Every area of human knowledge must be involved. This modular concept will let us see other space goals as extensions of the primary project. The basic technology has to be defined, then relatively minor adjustments will let us reach new objectives such as a first approach for a lunar base and for a Mars manned mission. This concept aims towards an open technology in which standards and recommendations will be created to assemble huge space bases and spaceships from specific modules that perform certain functions, that in combination will let us reach the status of permanent use and exploration of space.

  13. La communication engageante au service d'une problématique de sécurité routière : la réduction de la vitesse des conducteurs de deux-roues motorisés

    OpenAIRE

    TAMISIER , Damien

    2017-01-01

    Speed is a major road safety issue and is identified as one of the main risk factors for accident rate and aggravation of powered two-wheelers (PTW) drivers' injuries. Road safety campaigns resorting persuasive communication which seeks to change the attitude of road users in order to impact behaviour showed contrasting effects. Considering the strength of PTW drivers' attitudes towards speed allows reporting on the limitations of persuasion which encouraged a paradigmatic renewal through the...

  14. Modulator-free quadrature amplitude modulation signal synthesis

    Science.gov (United States)

    Liu, Zhixin; Kakande, Joseph; Kelly, Brian; O'Carroll, John; Phelan, Richard; Richardson, David J.; Slavík, Radan

    2014-12-01

    The ability to generate high-speed on-off-keyed telecommunication signals by directly modulating a semiconductor laser’s drive current was one of the most exciting prospective applications of the nascent field of laser technology throughout the 1960s. Three decades of progress led to the commercialization of 2.5 Gbit s-1-per-channel submarine fibre optic systems that drove the growth of the internet as a global phenomenon. However, the detrimental frequency chirp associated with direct modulation forced industry to use external electro-optic modulators to deliver the next generation of on-off-keyed 10 Gbit s-1 systems and is absolutely prohibitive for today’s (>)100 Gbit s-1 coherent systems, which use complex modulation formats (for example, quadrature amplitude modulation). Here we use optical injection locking of directly modulated semiconductor lasers to generate complex modulation format signals showing distinct advantages over current and other currently researched solutions.

  15. The development and preliminary testing of a multimedia patient–provider survivorship communication module for breast cancer survivors

    Science.gov (United States)

    Wen, Kuang-Yi; Miller, Suzanne M.; Stanton, Annette L.; Fleisher, Linda; Morra, Marion E.; Jorge, Alexandra; Diefenbach, Michael A.; Ropka, Mary E.; Marcus, Alfred C.

    2012-01-01

    Objective This paper describes the development of a theory-guided and evidence-based multimedia training module to facilitate breast cancer survivors’ preparedness for effective communication with their health care providers after active treatment. Methods The iterative developmental process used included: (1) theory and evidence-based content development and vetting; (2) user testing; (3) usability testing; and (4) participant module utilization. Results Formative evaluation of the training module prototype occurred through user testing (n = 12), resulting in modification of the content and layout. Usability testing (n = 10) was employed to improve module functionality. Preliminary web usage data (n = 256, mean age = 53, 94.5% White, 75% college graduate and above) showed that 59% of the participants accessed the communication module, for an average of 7 min per login. Conclusion The iterative developmental process was informative in enhancing the relevance of the communication module. Preliminary web usage results demonstrate the potential feasibility of such a program. Practice implications Our study demonstrates survivors’ openness to the use of a web-based communication skills training module and outlines a systematic iterative user and interface program development and testing process, which can serve as a prototype for others considering such an approach. PMID:22770812

  16. The development and preliminary testing of a multimedia patient-provider survivorship communication module for breast cancer survivors.

    Science.gov (United States)

    Wen, Kuang-Yi; Miller, Suzanne M; Stanton, Annette L; Fleisher, Linda; Morra, Marion E; Jorge, Alexandra; Diefenbach, Michael A; Ropka, Mary E; Marcus, Alfred C

    2012-08-01

    This paper describes the development of a theory-guided and evidence-based multimedia training module to facilitate breast cancer survivors' preparedness for effective communication with their health care providers after active treatment. The iterative developmental process used included: (1) theory and evidence-based content development and vetting; (2) user testing; (3) usability testing; and (4) participant module utilization. Formative evaluation of the training module prototype occurred through user testing (n = 12), resulting in modification of the content and layout. Usability testing (n = 10) was employed to improve module functionality. Preliminary web usage data (n = 256, mean age = 53, 94.5% White, 75% college graduate and above) showed that 59% of the participants accessed the communication module, for an average of 7 min per login. The iterative developmental process was informative in enhancing the relevance of the communication module. Preliminary web usage results demonstrate the potential feasibility of such a program. Our study demonstrates survivors' openness to the use of a web-based communication skills training module and outlines a systematic iterative user and interface program development and testing process, which can serve as a prototype for others considering such an approach. Copyright © 2012. Published by Elsevier Ireland Ltd.

  17. LOFT fuel module structural response during loss-of-coolant experiments

    International Nuclear Information System (INIS)

    Saffell, B.F. Jr.; Selcho, H.S.

    1979-01-01

    The structural response of the reactor fuel modules installed in the Loss-of-Fluid Test (LOFT) facility have been analyzed for subcooled blowdown loading conditions associated with loss-of-coolant experiments (LOCE). Three independent analyses using the WHAM, SHOCK, and SAP computer codes have been interfaced to calculate the transient mechanical behavior of the LOFT fuel. Test data from two LOCEs indicate the analysis method is conservative. Structural integrity of the fuel modules has been assessed by monitoring guide tube temperatures and control rod drop times during the LOCEs. The analysis and experimental test data indicate the fuel module structural integrity will be maintained for the duration of the LOFT experimental program

  18. Transitioning Communication Education to an Interactive Online Module Format.

    Science.gov (United States)

    Williams, Kristine; Abd-Hamid, Nor Hashidah; Perkhounkova, Yelena

    2017-07-01

    The Changing Talk intervention improves nursing home staff communication by reducing elderspeak. To facilitate dissemination, interactive online modules were created, maintaining the original content. This article reports on the process of transitioning and the results of pilot testing the modules. Interactive online modules were developed, pilot tested, and the evaluated in comparison to outcomes from the classroom format training. Online participants (N = 9) demonstrated pre to posttest knowledge gain (scores improved from M = 82.4% to M = 91.2%). Rating of a staff-resident interaction showed improved recognition of elderspeak and person-centered communication after training. Online and original participants reported similar intentions to use learned skills and rated the program highly. Evidence-based interventions can be translated from traditional classroom to online format maintaining effects on increasing staff knowledge and intentions to use learned skills in practice. However, the modules should be tested in a larger and more representative sample. J Contin Educ Nurs. 2017;48(7):320-328. Copyright 2017, SLACK Incorporated.

  19. Current progress of Chinese HCCB TBM program

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Kaiming, E-mail: fengkm@swip.ac.cn [Southwestern Institute of Physics, Shuang Liu, Chengdu 610225 (China); Wang, Xiaoyu; Feng, Yongjin; Chen, Yanjing; Zhao, Zhou; Li, Zaixin; Wang, Pinghua; Wang, Qijie; Ye, Xingfu; Zhao, Fengchao; Zhang, Long; Wang, Feng; Chao, Qixiang; Wu, Xinghua; Wang, Yanlin; Wang, Jun; Liu, Yang; Yang, Li; Chen, Yinfen; Yu, Guo [Southwestern Institute of Physics, Shuang Liu, Chengdu 610225 (China); and others

    2016-11-01

    Highlights: • China plan to test own test blanket modules (TBM) during ITER different operation phase (H-H,D-D, D-T). • A preliminary design (PD) of HCCB TBM have being performed since 2014. • In order to reduce the effects of magnetic field ripple, the HCCB TBM design has been updated with reduced RAFM mass. • Related R&D on key components fabrication, welding technology, materials development, He test loop constraction and mock-up test of TBM modules and components have being implemented. • The current status on design and related R&D, as well as the development of auxiliary system (TES, CPS,HCS, etc.,) of Chinese HCCB TBS program ware overviewed. - Abstract: ITER is an unique opportunity to test tritium breeding blanket mock-ups in integrated Tokamak operating conditions. Helium-cooled ceramic breeder (HCCB) test blanket module will be the primary option of the Chinese ITER TBM program. China plans to test its own test blanket modules (TBM) during ITER different operation phase (H-H,D-D, D-T). A preliminary design of HCCB TBM have been completed in 2013. In order to reduce the effects of magnetic field ripple, the HCCB TBM design has been updated with reduced RAFM mass recently. Related R&D on key components fabrication, welding technology, materials development and mock-up test of TBM modules and components have being implemented. In this paper, the current status on design and related R&D, as well as the development of auxiliary system (TES, CPS,HCS, etc.,) of Chinese HCCB TBS program were introduced.

  20. Current progress of Chinese HCCB TBM program

    International Nuclear Information System (INIS)

    Feng, Kaiming; Wang, Xiaoyu; Feng, Yongjin; Chen, Yanjing; Zhao, Zhou; Li, Zaixin; Wang, Pinghua; Wang, Qijie; Ye, Xingfu; Zhao, Fengchao; Zhang, Long; Wang, Feng; Chao, Qixiang; Wu, Xinghua; Wang, Yanlin; Wang, Jun; Liu, Yang; Yang, Li; Chen, Yinfen; Yu, Guo

    2016-01-01

    Highlights: • China plan to test own test blanket modules (TBM) during ITER different operation phase (H-H,D-D, D-T). • A preliminary design (PD) of HCCB TBM have being performed since 2014. • In order to reduce the effects of magnetic field ripple, the HCCB TBM design has been updated with reduced RAFM mass. • Related R&D on key components fabrication, welding technology, materials development, He test loop constraction and mock-up test of TBM modules and components have being implemented. • The current status on design and related R&D, as well as the development of auxiliary system (TES, CPS,HCS, etc.,) of Chinese HCCB TBS program ware overviewed. - Abstract: ITER is an unique opportunity to test tritium breeding blanket mock-ups in integrated Tokamak operating conditions. Helium-cooled ceramic breeder (HCCB) test blanket module will be the primary option of the Chinese ITER TBM program. China plans to test its own test blanket modules (TBM) during ITER different operation phase (H-H,D-D, D-T). A preliminary design of HCCB TBM have been completed in 2013. In order to reduce the effects of magnetic field ripple, the HCCB TBM design has been updated with reduced RAFM mass recently. Related R&D on key components fabrication, welding technology, materials development and mock-up test of TBM modules and components have being implemented. In this paper, the current status on design and related R&D, as well as the development of auxiliary system (TES, CPS,HCS, etc.,) of Chinese HCCB TBS program were introduced.

  1. Computer program design specifications for the Balloon-borne Ultraviolet Stellar Spectrometer (BUSS) science data decommutation program (BAPS48)

    Science.gov (United States)

    Rodriguez, R. M.

    1975-01-01

    The Balloon-Borne Ultraviolet Stellar Spectrometer (BUSS) Science Data Docummutation Program (BAPS48) is a pulse code modulation docummutation program that will format the BUSS science data contained on a one inch PCM tracking tape into a seven track serial bit stream formatted digital tape.

  2. Considering Maternal Dietary Modulators for Epigenetic Regulation and Programming of the Fetal Epigenome

    Directory of Open Access Journals (Sweden)

    Abalo Chango

    2015-04-01

    Full Text Available Fetal life is characterized by a tremendous plasticity and ability to respond to various environmental and lifestyle factors, including maternal nutrition. Identification of the role of dietary factors that can modulate and reshape the cellular epigenome during development, including methyl group donors (e.g., folate, choline and bioactive compounds (e.g., polyphenols is of great importance; however, there is insufficient knowledge of a particular effect of each type of modulator and/or their combination on fetal life. To enhance the quality and safety of food products for proper fetal health and disease prevention in later life, a better understanding of the underlying mechanisms of dietary epigenetic modulators during the critical prenatal period is necessary. This review focuses on the influence of maternal dietary components on DNA methylation, histone modification, and microRNAs, and summarizes current knowledge of the effect and importance of dietary components on epigenetic mechanisms that control the proper expression of genetic information. Evidence reveals that some components in the maternal diet can directly or indirectly affect epigenetic mechanisms. Understanding the underlying mechanisms of how early-life nutritional environment affects the epigenome during development is of great importance for the successful prevention of adult chronic diseases through optimal maternal nutrition.

  3. Considering maternal dietary modulators for epigenetic regulation and programming of the fetal epigenome.

    Science.gov (United States)

    Chango, Abalo; Pogribny, Igor P

    2015-04-14

    Fetal life is characterized by a tremendous plasticity and ability to respond to various environmental and lifestyle factors, including maternal nutrition. Identification of the role of dietary factors that can modulate and reshape the cellular epigenome during development, including methyl group donors (e.g., folate, choline) and bioactive compounds (e.g., polyphenols) is of great importance; however, there is insufficient knowledge of a particular effect of each type of modulator and/or their combination on fetal life. To enhance the quality and safety of food products for proper fetal health and disease prevention in later life, a better understanding of the underlying mechanisms of dietary epigenetic modulators during the critical prenatal period is necessary. This review focuses on the influence of maternal dietary components on DNA methylation, histone modification, and microRNAs, and summarizes current knowledge of the effect and importance of dietary components on epigenetic mechanisms that control the proper expression of genetic information. Evidence reveals that some components in the maternal diet can directly or indirectly affect epigenetic mechanisms. Understanding the underlying mechanisms of how early-life nutritional environment affects the epigenome during development is of great importance for the successful prevention of adult chronic diseases through optimal maternal nutrition.

  4. A nanobody modulates the p53 transcriptional program without perturbing its functional architecture

    Science.gov (United States)

    Bethuyne, Jonas; De Gieter, Steven; Zwaenepoel, Olivier; Garcia-Pino, Abel; Durinck, Kaat; Verhelle, Adriaan; Hassanzadeh-Ghassabeh, Gholamreza; Speleman, Frank; Loris, Remy; Gettemans, Jan

    2014-01-01

    The p53 transcription factor plays an important role in genome integrity. To perform this task, p53 regulates the transcription of genes promoting various cellular outcomes including cell cycle arrest, apoptosis or senescence. The precise regulation of this activity remains elusive as numerous mechanisms, e.g. posttranslational modifications of p53 and (non-)covalent p53 binding partners, influence the p53 transcriptional program. We developed a novel, non-invasive tool to manipulate endogenous p53. Nanobodies (Nb), raised against the DNA-binding domain of p53, allow us to distinctively target both wild type and mutant p53 with great specificity. Nb3 preferentially binds ‘structural’ mutant p53, i.e. R175H and R282W, while a second but distinct nanobody, Nb139, binds both mutant and wild type p53. The co-crystal structure of the p53 DNA-binding domain in complex with Nb139 (1.9 Å resolution) reveals that Nb139 binds opposite the DNA-binding surface. Furthermore, we demonstrate that Nb139 does not disturb the functional architecture of the p53 DNA-binding domain using conformation-specific p53 antibody immunoprecipitations, glutaraldehyde crosslinking assays and chromatin immunoprecipitation. Functionally, the binding of Nb139 to p53 allows us to perturb the transactivation of p53 target genes. We propose that reduced recruitment of transcriptional co-activators or modulation of selected post-transcriptional modifications account for these observations. PMID:25324313

  5. Noise Simulation of Continuous-Time ΣΔ Modulators

    International Nuclear Information System (INIS)

    Arias, J.; Quintanilla, L.; Bisbal, D.; San Pablo, J.; Enriquez, L.; Vicente, J.; Barbolla, J.

    2005-01-01

    In this work, an approach for the simulation of the effect of noise sources in the performance of continuous-time ΔΣ modulators is presented. Electrical noise including thermal noise, 1/f noise and clock jitter are included in a simulation program and their impact on the system performance is analyzed

  6. Configuration Management Program Application at KNPP Units 5 and 6 Modernization Program

    International Nuclear Information System (INIS)

    Manchev, B.; Yordanova, V.; Nenkova, B.

    2006-01-01

    The need for Configuration Management Program development, became very clear after the initiation of the Modernization Program for Units 5and6, because KNPP personnel needed a good and safe way to control the huge amount of data which were transferred into two directions - input data (design and operational documents from KNPP to Contractors) and the design, vendor, procurement, etc. documents (from Contractors to KNPP). Moreover, most of the measures are in fact design changes and it appeared to be extremely important to track these design changes and their reflection into design and operational documents. It is even more important to obtain a successful transfer of all this information to the operating organization (EP-2) after the completion. The proposal for development of Configuration Management (CM) Program for KNPP Units 5and6 Modernization program was divided into three phases: 1. Information Control (Document Control and Records Management) 2.Technical Decision System (Change Control) 3. Master Equipment List (MEL), (as part of the Design requirements element) Information Control Element was chosen to be developed first. Implementation of Information Control element comprised of: Review and assessment of existing situation (procedures for document control and records Management), Development of new/revision of existing procedure for Document Control and Records Management, Development of SmartDoc software application in support of document control and records management and for measure documentation tracking (with its specifics), Data entry for MP5and6 measures, Implementation at EP-2 (with successful data migration from the existing databases). The SmartDoc development was completed at the end of 2002 and after a testing period it was implemented at Modernization and Investment Department first. Then the data for documents were transferred from the existing databases at EP-2 and the system was implemented at EP-2 and other KNPP facilities. Development

  7. Development of support tools for efficient construction of dynamic simulation program for engineering systems

    International Nuclear Information System (INIS)

    Gofuku, Akio

    1993-01-01

    In this study, two support tools are developed for construction of a dynamic simulation program for engineering systems (especially nuclear systems) by combining software modules. These are (1) a sub-system to support the module selection suitable for dynamic simulation and (2) a graphical user interface to support visual construction of simulation programs. The support tools are designed to be independent on the conception of software modules (data communication methods between modules). In the module selection sub-system of item 1, a module is characterized beforehand by keywords for several criteria. The similarity between the characteristic of requested module by users and that of registered modules in the module library is estimated by a weighted average of similarity indexes for criteria. In the module selection sub-system, the weights are flexibly extracted from users by applying the analytic hierarchy process. The graphical user interface helps users to specify both calling order of modules and data transfer between two modules. The availability of the support tools is evaluated by several sample problems of module selection and dynamic simulation model construction. The support tools will be a strong tool for the efficient usage of software modules. (author)

  8. ANAUSN - a one-dimensional multigroup SN transport theory module for the AUS reactor neutronics system

    International Nuclear Information System (INIS)

    Clancy, B.E.

    1982-05-01

    ANAUSN is a general purpose, one-dimensional discrete ordinate transport theory program which has access to AUS datapools. Fixed source, reactivity and a variety of criticality search calculations can be performed. The program can be operated as a module in the AUS scheme or as a stand-alone program

  9. Establishment of postal audit system in intensity-modulated radiotherapy by radiophotoluminescent glass dosimeters and a radiochromic film.

    Science.gov (United States)

    Okamoto, Hiroyuki; Minemura, Toshiyuki; Nakamura, Mitsuhiro; Mizuno, Hideyuki; Tohyama, Naoki; Nishio, Teiji; Wakita, Akihisa; Nakamura, Satoshi; Nishioka, Shie; Iijima, Kotaro; Fujiyama, Daisuke; Itami, Jun; Nishimura, Yasumasa

    2018-04-01

    We developed an efficient postal audit system to independently assess the delivered dose using radiophotoluminescent glass dosimeters (RPLDs) and the positional differences of fields using EBT3 film at the axial plane for intensity-modulated radiotherapy (IMRT). The audit phantom had a C-shaped target structure as a planning target volume (PTV) with four measurement points for the RPLDs and a cylindrical structure as the organ at risk (OAR) for one measurement point. The phantoms were sent to 24 institutions. Point dose measurements with a 0.6 cm 3 PTW farmer chamber were also performed to justify glass dosimetry in IMRT. The measured dose with the RPLDs was compared to the calculated dose in the institution's treatment planning system (TPS). The mean ± 1.96σ of the ratio of the measured dose with the RPLDs to the farmer chamber was 0.997 ± 0.024 with no significant difference (p = .175). The investigations demonstrated that glass dosimetry was reliable with a high measurement accuracy comparable to the chamber. The mean ± 1.96σ for the dose differences with a reference of the TPS dose for the PTV and the OAR was 0.1 ± 2.5% and -2.1 ± 17.8%, respectively. The mean ± 1.96σ for the right-left and the anterior-posterior direction was -0.9 ± 2.8 and 0.5 ± 1.4 mm, respectively. This study is the first report to justify glass dosimetry for implementation in IMRT audit in Japan. We demonstrate that our postal audit system has high accuracy with a high-level criterion of 3%/3 mm. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  10. Programmable type III-A CRISPR-Cas DNA targeting modules.

    Directory of Open Access Journals (Sweden)

    H Travis Ichikawa

    Full Text Available The CRISPR-Cas systems provide invader defense in a wide variety of prokaryotes, as well as technologies for many powerful applications. The Type III-A or Csm CRISPR-Cas system is one of the most widely distributed across prokaryotic phyla, and cleaves targeted DNA and RNA molecules. In this work, we have constructed modules of Csm systems from 3 bacterial species and heterologously expressed the functional modules in E. coli. The modules include a Cas6 protein and a CRISPR locus for crRNA production, and Csm effector complex proteins. The expressed modules from L. lactis, S. epidermidis and S. thermophilus specifically eliminate invading plasmids recognized by the crRNAs of the systems. Characteristically, activation of plasmid targeting activity depends on transcription of the plasmid sequence recognized by the crRNA. Activity was not observed when transcription of the crRNA target sequence was blocked, or when the opposite strand or a non-target sequence was transcribed. Moreover, the Csm module can be programmed to recognize plasmids with novel target sequences by addition of appropriate crRNA coding sequences to the module. These systems provide a platform for investigation of Type III-A CRISPR-Cas systems in E. coli, and for introduction of programmable transcription-activated DNA targeting into novel organisms.

  11. System for Automated Calibration of Vector Modulators

    Science.gov (United States)

    Lux, James; Boas, Amy; Li, Samuel

    2009-01-01

    Vector modulators are used to impose baseband modulation on RF signals, but non-ideal behavior limits the overall performance. The non-ideal behavior of the vector modulator is compensated using data collected with the use of an automated test system driven by a LabVIEW program that systematically applies thousands of control-signal values to the device under test and collects RF measurement data. The technology innovation automates several steps in the process. First, an automated test system, using computer controlled digital-to-analog converters (DACs) and a computer-controlled vector network analyzer (VNA) systematically can apply different I and Q signals (which represent the complex number by which the RF signal is multiplied) to the vector modulator under test (VMUT), while measuring the RF performance specifically, gain and phase. The automated test system uses the LabVIEW software to control the test equipment, collect the data, and write it to a file. The input to the Lab - VIEW program is either user-input for systematic variation, or is provided in a file containing specific test values that should be fed to the VMUT. The output file contains both the control signals and the measured data. The second step is to post-process the file to determine the correction functions as needed. The result of the entire process is a tabular representation, which allows translation of a desired I/Q value to the required analog control signals to produce a particular RF behavior. In some applications, corrected performance is needed only for a limited range. If the vector modulator is being used as a phase shifter, there is only a need to correct I and Q values that represent points on a circle, not the entire plane. This innovation has been used to calibrate 2-GHz MMIC (monolithic microwave integrated circuit) vector modulators in the High EIRP Cluster Array project (EIRP is high effective isotropic radiated power). These calibrations were then used to create

  12. Programming PHREEQC calculations with C++ and Python a comparative study

    Science.gov (United States)

    Charlton, Scott R.; Parkhurst, David L.; Muller, Mike

    2011-01-01

    The new IPhreeqc module provides an application programming interface (API) to facilitate coupling of other codes with the U.S. Geological Survey geochemical model PHREEQC. Traditionally, loose coupling of PHREEQC with other applications required methods to create PHREEQC input files, start external PHREEQC processes, and process PHREEQC output files. IPhreeqc eliminates most of this effort by providing direct access to PHREEQC capabilities through a component object model (COM), a library, or a dynamically linked library (DLL). Input and calculations can be specified through internally programmed strings, and all data exchange between an application and the module can occur in computer memory. This study compares simulations programmed in C++ and Python that are tightly coupled with IPhreeqc modules to the traditional simulations that are loosely coupled to PHREEQC. The study compares performance, quantifies effort, and evaluates lines of code and the complexity of the design. The comparisons show that IPhreeqc offers a more powerful and simpler approach for incorporating PHREEQC calculations into transport models and other applications that need to perform PHREEQC calculations. The IPhreeqc module facilitates the design of coupled applications and significantly reduces run times. Even a moderate knowledge of one of the supported programming languages allows more efficient use of PHREEQC than the traditional loosely coupled approach.

  13. A multiobjective module-order model for software quality enhancement

    NARCIS (Netherlands)

    Khoshgoftaar, TM; Liu, Y; Seliya, N

    2004-01-01

    The knowledge, prior to system operations, of which program modules are problematic is valuable to a software quality assurance team, especially when there is a constraint on software quality enhancement resources. A cost-effective approach for allocating such resources is to obtain a prediction in

  14. Modulární fulltextový vyhledávač pro MySQL

    OpenAIRE

    Baroš, Martin

    2007-01-01

    An objective of the project is to develop a modular fulltext search engine using MySQL database server. The search engine should operate with the Czech language's specific attributes. There is no endeavor to develop high quality modules solving linguistic problems. Project should provide interface and ability to plug-in (plug-out) next modules. Project's software platform is Unix, programming language C++.

  15. IEEE Std 381-1977: IEEE standard criteria for type tests of Class 1E modules used in nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This document describes the basic requirements of a type test program with the objective of verifying that a module used as Class 1E equipment in a nuclear power generating station meets or exceeds its design specifications. This document is limited to class 1E modules from and including the sensor through the logic circuitry of the final actuation devices. Except for those that are part of a module, switchgear, cables, connections, motors, valve actuators, station batteries, and penetrations are not included and are covered by other IEEE documents. The purpose of this document is to supplement the procedures and requirements given in IEEE Std 323-1974 [24] for type testing Class 1E modules, thereby providing directions for establishment of a type test program which will obtain the required test data and yield the required documentation of test methods and results. This standard is structured to present to the user the principal performance characteristics and environmental parameters which must be considered in designing a type test program for any give Class 1E module. These modules range from tiny sensors to complete racks or cabinets full of equipment that may be located inside or outside containment. The Class 1E modules are required to perform their function before, during, or after, or all, any design basis event specified for the module. The vast variety of modules covered by this document precludes the listing here of specific requirements for each type test

  16. The fastbus trigger modules for the SAT detector in the DELPHI experiment at LEP, CERN

    International Nuclear Information System (INIS)

    Alvsvaag, S.J.

    1992-09-01

    This thesis describes the functionality and performance of the fastbus trigger modules for the Small Angle Tagger (SAT) detector in the DELPHI experiment at the LEP machine at CERN. The main purpose of the modules is to provide a Bhabha trigger for the SAT calorimeter used for luminosity measurements. The author has bee responsible for the design, production, testing and installation of the trigger modules. All the test programs necessary to confirm that the modules function according to the specifications are included in this work. Is does not, however, aim to make detailed technical descriptions of the modules. 44 refs., 39 figs., 18 tabs

  17. Evaluation of Maxim Module-Integrated Electronics at the DOE Regional Test Centers: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Deline, C.; Sekulic, B.; Stein, J.; Barkaszi, S.; Yang, J.; Kahn, S.

    2014-07-01

    Module-embedded power electronics developed by Maxim Integrated are under evaluation through a partnership with the Department of Energy's Regional Test Center (RTC) program. Field deployments of both conventional modules and electronics-enhanced modules are designed to quantify the performance advantage of Maxim's products under different amounts of inter-row shading, and their ability to be deployed at a greater ground-coverage-ratio than conventional modules. Simulations in PVSYST have quantified the predicted performance difference between conventional modules and Maxim's modules from inter-row shading. Initial performance results have identified diffuse irradiance losses at tighter row spacing for both the Maxim and conventional modules. Comparisons with published models show good agreement with models predicting the greatest diffuse irradiance losses. At tighter row spacing, all of the strings equipped with embedded power electronics outperformed their conventional peers. An even greater performance advantage is predicted to occur in the winter months when the amount of inter-row shading mismatch is at a maximum.

  18. Photovoltaic module and interlocked stack of photovoltaic modules

    Science.gov (United States)

    Wares, Brian S.

    2012-09-04

    One embodiment relates to an arrangement of photovoltaic modules configured for transportation. The arrangement includes a plurality of photovoltaic modules, each photovoltaic module including a frame having at least a top member and a bottom member. A plurality of alignment features are included on the top member of each frame, and a plurality of alignment features are included on the bottom member of each frame. Adjacent photovoltaic modules are interlocked by the alignment features on the top member of a lower module fitting together with the alignment features on the bottom member of an upper module. Other embodiments, features and aspects are also disclosed.

  19. Dynamic simulator for nuclear power plants (DSNP): development, verification, and expansion of modules

    International Nuclear Information System (INIS)

    Larson, H.A.; Dean, E.M.; Koenig, J.F.; Gale, J.G.; Lehto, W.K.

    1984-01-01

    The DSNP Simulation Language facilitates whole reactor plant simulation and design. Verification includes DSNP dynamic modeling of Experimental Breeder Reactor No. 2 (EBR-II) plant experiments as well as comparisons with verified simulation programs. Great flexibility is allowed in expanding the DSNP language and accommodate other computer languages. The component modules of DSNP, contained in libraries, are continually updated with new, improved, and verified modules. The modules are used to simulate the dynamic response of LMFBR reactor systems to upset and transient conditions, with special emphasis on investigations of inherent shutdown mechanisms

  20. Fertilizing ROSES through the STEM: Interdisciplinary Modules as Pre-service Research Experiences for Secondary STEM Educators (IMPRESS-Ed)

    Science.gov (United States)

    Kavic, Michael; Wiita, P. J.; Benoit, M.; Magee, N.

    2013-01-01

    IMPRESS-Ed is a program designed to provide authentic summer research experiences in the space, earth, and atmospheric sciences for pre-service K-12 educators at Long Island University (LIU) and The College of New Jersey (TCNJ). In 2011 and 2012, the program involved five students and took place over eight weeks with recruitment occurring during the preceding academic year. The program was divided into two modules: A common core module and an individual mentored research experience. The common module consisted of three units focusing on data-driven pedagogical approaches in astrophysics, tectonophysics, and atmospheric science, respectively. The common module also featured training sessions in observational astronomy, and use of a 3D geowall and state of the art planetarium. Participants in the program are also offered the opportunity to utilize the available TCNJ facilities with their future students. The individual mentored research module matched student interests with potential projects. All five students demonstrated strong gains in earth and space science literacy compared to a baseline measurement. Each student also reported gaining confidence to incorporate data and research-driven instruction in the space and earth sciences into the K-12 STEM classroom setting. All five research projects were also quite successful: several of the students plan to continue research during the academic year and two students are presenting research findings as first authors here at AAS. Other research results are likely to be presented at this year's American Geophysical Union meeting.

  1. Development of performance analysis support modules in Younggwang NPP unit 3 and 4

    International Nuclear Information System (INIS)

    Heo, G. Y.; Lee, S. J.; Jang, S. H.; Choi, S. S.; Choi, Q. H.; Gee, M. H.; Heo, I.

    2003-01-01

    This paper covers the unmeasured parameter estimation module, the performance degradation estimation module, and the performance degradation diagnosis module that are the supporting modules of the thermal performance analysis program of Younggwang nuclear power plant unit 3 and 4, PERUPS (PERformance UPgrade System), which was developed by KHNP, KEPRI, Hoseo university, and ACT. The unmeasured parameter estimation module plays a role in the generation of estimated values for the parameters that are necessary but there are no sensors. The performance degradation estimation module shows the impact for electric gain and loss according to the parameters related to turbine cycle performance. The performance degradation diagnosis module provides the belief according degradation causes considering the measurement uncertainty, analysis uncertainty, and correlation among parameters. Reference data for the development of each module was prepared by a turbine cycle simulation tool, PEPSE. The unmeasured parameter estimation module and the performance degradation estimation module make the estimation correlations by the regression analysis using the reference data. In the performance degradation diagnosis module, Bayesian network is used for the modeling of uncertainty and knowledge-base. The validation of the developed modules was performed by the test data generated by PEPSE, and accomplished by the actual data again

  2. Traffic safety analysis of powered two-wheelers (PTWs) in Slovenia.

    Science.gov (United States)

    Šraml, Matjaž; Tollazzi, Tomaž; Renčelj, Marko

    2012-11-01

    Due to the 2006 European research report on powered two-wheelers (PTWs) riders' traffic safety, Slovenia represents the highest risk for PTW riders in the European Union. Namely, in Slovenia we have the largest number of PTW riders' deaths per billion travelled kilometers in 2006. Since then the traffic safety situation in the field of PTW riders in Slovenia has been improving and we will discuss that phenomenon in the present paper. The paper identifies and analyzes the causes that led to such a critical situation. Further, the evaluation of activities that were carried out to improve the road safety for powered two-wheeler riders in Slovenia in the last past years are discussed. In conclusion a selection of measures and actions is presented that already has been and also should be carried out in the future. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Exposure calculation code module for reactor core analysis: BURNER

    Energy Technology Data Exchange (ETDEWEB)

    Vondy, D.R.; Cunningham, G.W.

    1979-02-01

    The code module BURNER for nuclear reactor exposure calculations is presented. The computer requirements are shown, as are the reference data and interface data file requirements, and the programmed equations and procedure of calculation are described. The operating history of a reactor is followed over the period between solutions of the space, energy neutronics problem. The end-of-period nuclide concentrations are determined given the necessary information. A steady state, continuous fueling model is treated in addition to the usual fixed fuel model. The control options provide flexibility to select among an unusually wide variety of programmed procedures. The code also provides user option to make a number of auxiliary calculations and print such information as the local gamma source, cumulative exposure, and a fine scale power density distribution in a selected zone. The code is used locally in a system for computation which contains the VENTURE diffusion theory neutronics code and other modules.

  4. Exposure calculation code module for reactor core analysis: BURNER

    International Nuclear Information System (INIS)

    Vondy, D.R.; Cunningham, G.W.

    1979-02-01

    The code module BURNER for nuclear reactor exposure calculations is presented. The computer requirements are shown, as are the reference data and interface data file requirements, and the programmed equations and procedure of calculation are described. The operating history of a reactor is followed over the period between solutions of the space, energy neutronics problem. The end-of-period nuclide concentrations are determined given the necessary information. A steady state, continuous fueling model is treated in addition to the usual fixed fuel model. The control options provide flexibility to select among an unusually wide variety of programmed procedures. The code also provides user option to make a number of auxiliary calculations and print such information as the local gamma source, cumulative exposure, and a fine scale power density distribution in a selected zone. The code is used locally in a system for computation which contains the VENTURE diffusion theory neutronics code and other modules

  5. A fine-grained, customizable debugger for aspect-oriented programming

    NARCIS (Netherlands)

    Yin, Haihan; Leavens, G.T.; Chiba, S.; Bockisch, Christoph; Aksit, Mehmet; Tanter, E.

    2013-01-01

    To increase modularity, many aspect-oriented programming languages provide a mechanism based on implicit invocation: An aspect can influence runtime behavior of other modules without the need that these modules refer to the aspect. Recent studies show that a significant part of reported bugs in

  6. Reliability Evaluation of Concentrator Photovoltaic Modules per IEC Qualification Specifications

    Energy Technology Data Exchange (ETDEWEB)

    Tamizhmani, Govindasamy

    2012-12-05

    This project is related to the qualification testing of new generation CPV (concentrator photovoltaics) modules at lower testing costs and lower turnaround time. In this project, the first testing program was completed for two CPV manufacturers, the second testing program was completed for two manufacturers at 65% of the actual testing cost and at less than 3 months of testing turnaround time and the third testing program was completed for two manufacturers at 65% of the actual testing cost and at less than 3 months of testing turnaround time. Due to their financial situation and restructuring, Amonix (one of the CPV manufacturers) intermittently terminated the test programs.

  7. THE MODULE--A NEW MODE FOR GAINING FLEXIBILITY.

    Science.gov (United States)

    PALMER, L. R.

    FLEXIBLE SCHEDULING BENEFITS BOTH STUDENTS AND TEACHERS BECAUSE, IN ANY SPECIFIC SCHOOLS EDUCATIONAL PROGRAM, IT MAKES THE BEST AND MOST APPROPRIATE USE OF TIME, SPACE, EQUIPMENT, AND TEACHERS TALENTS. SUCH SCHEDULING HAS BEEN USED SUCCESSFULLY AT MINNETONKA EAST JUNIOR HIGH SCHOOL, WHERE THE SCHOOL DAY IS DIVIDED INTO 15 DAILY TIME MODULES OF 28…

  8. Analysis of autonomic modulation of heart rate in patients with Parkinson's disease and elderly individuals submitted to game therapy training.

    Science.gov (United States)

    Rocha, Rodrigo Santiago Barbosa; De Oliveira Rocha, Larissa Salgado; Pena, Elza Sara Maués; Caldas, Laiz Cristinna Ponce; Moreno, Marlene Aparecida

    2018-01-01

    Elderly patients and individuals with Parkinson's disease have a reduction in autonomic heart rate modulation, which may influence the survival of these patients, and rehabilitation can minimize this event. We tested the hypothesis that rehabilitation protocol with game console would influence the cardiac autonomic modulation of patients with Parkinson's Disease. Eight-seven volunteers were divided into two groups, control (n = 45) and Parkinson's (n = 42), they completed the study 40 volunteers in the control group (CG) and 31 patients in the Parkinson group (PG), and subjected to 24 sessions of game therapy physiotherapy, thrice a week. Analysis of autonomic HR modulation was conducted before and after the rehabilitation program using a Polar RS800CX HR sensor. For the analysis of heart rate variability the data were transferred to the Kubios HRV 2.2 program. Statistical analysis was performed in the Biostat 5.2 program, the comparison of the data by ANOVA followed by Tukey test, and the general characteristics by the chi-square test. The critical value for rejecting the null hypothesis was set at P modulation of HR values. Subjects with PD exhibit less autonomic modulation of HR and the rehabilitation protocol with game therapy improved autonomic modulation of HR. Geriatr Gerontol Int 2018; 18: 20-25. © 2017 Japan Geriatrics Society.

  9. Program Use and Outcome Change in a Web-Based Trauma Intervention: Individual and Social Factors.

    Science.gov (United States)

    Wang, Zhiyun; Wang, Jianping; Maercker, Andreas

    2016-09-09

    Insight into user adherence to Web-based intervention programs and into its relationship to intervention effect is needed. The objective of this study was to examine use of a Web-based self-help intervention program, the Chinese version of My Trauma Recovery (CMTR), among Chinese traumatized individuals, and to investigate the relationship between program use and user characteristics before the intervention and change in outcomes after the intervention and at 3-months' follow-up. The sample consisted of 56 urban survivors of different trauma types and 90 rural survivors of the 2008 Sichuan earthquake, who used the CMTR in 1 month on their own or guided by volunteers in a counseling center. Predictors were demographics (sex, age, highest education, marital status, and annual family income), health problems (trauma duration, posttraumatic symptoms, and depression), psychological factors (coping self-efficacy), and social factors (social functioning impairment and social support). Program use was assessed by general program usage (eg, number of visiting days) and program adherence (eg, webpages completed in modules). Outcome measures were the Posttraumatic Diagnostic Scale (PDS), Symptom Checklist 90-Depression (SCL-D), Trauma Coping Self-Efficacy scale (CSE), Crisis Support Scale (CSS), and Social Functioning Impairment questionnaire (SFI) adopted from the CMTR. (1) Program use: rural participants had a larger total number of visiting days (F1,144=40.50, Psocial factors at pretest. (3) Program use and outcomes change: in general, use of the triggers and self-talk modules showed a consistent positive association with improvement in PDS, SCL-D, SFI, and CSE. The relaxation module was associated with positive change in PDS, but with negative change in CSS and SFI. The professional help module was associated with positive change in SCL-D, but its use on the first day was associated with negative change in CSS and CSE. The unhelpful coping module was associated with

  10. Education and Training Module in Alertness Management

    Science.gov (United States)

    Mallis, M. M.; Brandt, S. L.; Oyung, R. L.; Reduta, D. D.; Rosekind, M. R.

    2006-01-01

    The education and training module (ETM) in alertness management has now been integrated as part of the training regimen of the Pilot Proficiency Awards Program ("WINGS") of the Federal Aviation Administration. Originated and now maintained current by the Fatigue Countermeasures Group at NASA Ames Research Center, the ETM in Alertness Management is designed to give pilots the benefit of the best and most recent research on the basics of sleep physiology, the causes of fatigue, and strategies for managing alertness during flight operations. The WINGS program is an incentive program that encourages pilots at all licensing levels to participate in recurrent training, upon completion of which distinctive lapel or tie pins (wings) and certificates of completion are awarded. In addition to flight training, all WINGS applicants must attend at least one FAA-sponsored safety seminar, FAA-sanctioned safety seminar, or industry recurrent training program. The Fatigue Countermeasures Group provides an FAA-approved industry recurrent training program through an on-line General Aviation (GA) WINGS ETM in alertness management to satisfy this requirement. Since 1993, the Fatigue Countermeasures Group has translated fatigue and alertness information to operational environments by conducting two-day ETM workshops oriented primarily toward air-carrier operations subject to Part 121 of the Federal Aviation Regulations pertaining to such operations. On the basis of the information presented in the two-day ETM workshops, an ETM was created for GA pilots and was transferred to a Web-based version. To comply with the requirements of the WINGS Program, the original Web-based version has been modified to include hypertext markup language (HTML) content that makes information easily accessible, in-depth testing of alertness-management knowledge, new interactive features, and increased informational resources for GA pilots. Upon successful completion of this training module, a participant

  11. Collaboration for cooperative work experience programs in biomedical engineering education.

    Science.gov (United States)

    Krishnan, Shankar

    2010-01-01

    Incorporating cooperative education modules as a segment of the undergraduate educational program is aimed to assist students in gaining real-life experience in the field of their choice. The cooperative work modules facilitate the students in exploring different realistic aspects of work processes in the field. The track records for cooperative learning modules are very positive. However, it is indeed a challenge for the faculty developing Biomedical Engineering (BME) curriculum to include cooperative work experience or internship requirements coupled with a heavy course load through the entire program. The objective of the present work is to develop a scheme for collaborative co-op work experience for the undergraduate training in the fast-growing BME programs. A few co-op/internship models are developed for the students pursuing undergraduate BME degree. The salient features of one co-op model are described. The results obtained support the proposed scheme. In conclusion, the cooperative work experience will be an invaluable segment in biomedical engineering education and an appropriate model has to be selected to blend with the overall training program.

  12. MOCUP, MCNP/ORIGEN Coupling Utility Programs

    International Nuclear Information System (INIS)

    SEIDL, Marcus

    2003-01-01

    1 - Description of program or function: MOCUP is a series of utility and data manipulation programs to solve time and space-dependent coupled neutronics/isotopics problems. 2 - Methods: The neutronics calculation is performed by the Los Alamos National Laboratory code system, version 4a or later (CCC-200 or CCC-660),and the depletion and isotopics calculation is performed by CCC-371/ORIGEN2.1 developed at Oak Ridge National Laboratory. MCNP and ORIGEN2.1 are NOT included in this package. MOCUP consists of three utility programs (mcnpPRO, origenPRO, compPRO) to, respectively, search the MCNP output and tally files for relevant cell and tally parameters, prepare ORIGEN2.1 input files and execute the ORIGEN2.1 runs, and search ORIGEN2.1 punch files for relevant isotope concentrations and produce new MCNP input files. A graphical user interface is provided for execution convenience. 3 - Restrictions on the complexity of the problem: At present, no mechanism exists for automatic serial execution of the program modules. The user must interface with the GUI to run each of the modules

  13. Logic and control module for the Fermilab booster beam damper

    International Nuclear Information System (INIS)

    Sandberg, B.R.

    1977-01-01

    A logic and control module is included in the electronic system of the booster superdamper. This module produces a 9-bit digital word that controls the delay of beam bunch position information in the Fermilab booster synchrotron so that it arrives at the damping electrodes at the same time as the bunch of beam to be corrected. This delay word generator also has an output feature that only allows delay time decreases as the booster synchrotron frequency program increases monotonically. Such a feature guards against low-index incidental FM from affecting the delay computations

  14. UTAP, U Tailings Assessment Program

    International Nuclear Information System (INIS)

    Holmes, Ron

    1998-01-01

    1 - Description of program or function: UTAP carries out probabilistic analyses of the behaviour and environmental effects of uranium mill tailings, following close-out of milling operations. The models have been designed to allow predictions to be made for distances up to 50 kilometers in all directions from the tailings area. The models include features which include the ability to incorporate different receptors and site characteristics and to deal with input parameters which vary with time. 2 - Method of solution: UTAP is composed of a number of modules. These may be classified as either component or control modules. Component modules (or models) are the programs directly concerned with the simulation of a uranium tailings physical system; that is the computer implementation of the mathematical models representing the uranium tailings pile and surrounding environment. Control modules provide the infrastructure for probabilistic analysis using the component modules. These functions include probabilistic sampling of input parameters such as constant, normal, log-normal, uniform, log-uniform, triangular, Weibull, Beta, arbitrary and correlated. The sampling method used is straight Monte Carlo. The radionuclides modelled are: natural uranium, total thorium, radium-226, radon-222 and lead-210. The pH of the reference uranium tailings site and a chained river-lake system are also modelled. For the afore- mentioned radionuclides the following pathways of dose to the receptors modelled: water consumption, fish consumption, radon inhalation, dust inhalation, vegetable consumption, animal produce consumption and ground-shine. 3 - Restrictions on the complexity of the problem: The maximum number of steps through time allowed is 300

  15. Leadership for All: An Internal Medicine Residency Leadership Development Program.

    Science.gov (United States)

    Moore, Jared M; Wininger, David A; Martin, Bryan

    2016-10-01

    Developing effective leadership skills in physicians is critical for safe patient care. Few residency-based models of leadership training exist. We evaluated residents' readiness to engage in leadership training, feasibility of implementing training for all residents, and residents' acceptance of training. In its fourth year, the Leadership Development Program (LDP) consists of twelve 90-minute modules (eg, Team Decision Making and Bias, Leadership Styles, Authentic Leadership) targeting all categorical postgraduate year (PGY) 1 residents. Modules are taught during regularly scheduled educational time. Focus group surveys and discussions, as well as annual surveys of PGY-1s assessed residents' readiness to engage in training. LDP feasibility was assessed by considering sustainability of program structures and faculty retention, and resident acceptance of training was assessed by measuring attendance, with the attendance goal of 8 of 12 modules. Residents thought leadership training would be valuable if content remained applicable to daily work, and PGY-1 residents expressed high levels of interest in training. The LDP is part of the core educational programming for PGY-1 residents. Except for 2 modules, faculty presenters have remained consistent. During academic year 2014-2015, 45% (13 of 29) of categorical residents participated in at least 8 of 12 modules, and 72% (21 of 29) participated in at least 7 of 12. To date, 125 categorical residents have participated in training. Residents appeared ready to engage in leadership training, and the LDP was feasible to implement. The attendance goal was not met, but attendance was sufficient to justify program continuation.

  16. BRAND program complex for neutron-physical experiment simulation by the Monte-Carlo method

    International Nuclear Information System (INIS)

    Androsenko, A.A.; Androsenko, P.A.

    1984-01-01

    Possibilities of the BRAND program complex for neutron and γ-radiation transport simulation by the Monte-Carlo method are described in short. The complex includes the following modules: geometric module, source module, detector module, modules of simulation of a vector of particle motion direction after interaction and a free path. The complex is written in the FORTRAN langauage and realized by the BESM-6 computer

  17. Domestic Wastewater Reuse in Concrete Using Bench-Scale Testing and Full-Scale Implementation

    Directory of Open Access Journals (Sweden)

    Ayoup M. Ghrair

    2016-08-01

    Full Text Available Demand for fresh water by the construction sector is expected to increase due to the high increase in the growth of construction activities in Jordan. This study aims to evaluate the potential of scale-up of the application of treated domestic wastewater in concrete from bench-scale to a full-scale. On the lab scale, concrete and mortar mixes using Primary and Secondary Treated Wastewater (PTW, STW and Distilled Water (DW were cast and tested after various curing ages (7, 28, 120, and 200 days. Based on wastewater quality, according to IS 456-2000, the STW is suitable for mortar and concrete production. Mortar made with STW at curing time up to 200 days has no significant negative effect on the mortar’s compressive strength. Conversely, the PTW exceeded the maximum permissible limits of total organic content and E coli. for concrete mixing-water. Using PTW results, a significant increase in the initial setting time of up to 16.7% and a decrease in the concrete workability are observed. In addition, using PTW as mixing water led to a significant reduction in the compressive strength up to 19.6%. The results that came out from scaling up to real production operation of ready-mix concrete were in harmony with the lab-scale results.

  18. Space station common module power system network topology and hardware development

    Science.gov (United States)

    Landis, D. M.

    1985-01-01

    Candidate power system newtork topologies for the space station common module are defined and developed and the necessary hardware for test and evaluation is provided. Martin Marietta's approach to performing the proposed program is presented. Performance of the tasks described will assure systematic development and evaluation of program results, and will provide the necessary management tools, visibility, and control techniques for performance assessment. The plan is submitted in accordance with the data requirements given and includes a comprehensive task logic flow diagram, time phased manpower requirements, a program milestone schedule, and detailed descriptions of each program task.

  19. Development of RFS. NUCIRC Interaction Module

    International Nuclear Information System (INIS)

    Choi, Geun Suk; Park, Joo Hwan

    2010-01-01

    For heavy water reactor core analysis and thermal hydraulic analysis, RFSP code and the NUCIRC code should be used consecutively. In this case the result of computation of one program is used for input data and information of the other program. For example, it is determining the channel flow distribution of 100% power from the NUCIRC code by using time-averaged bundle power distribution data of 100% power calculated from the RFSP code. However, a result of coming out of the RFSP code don't give converged input data about bundle power. Because of that, it calculates many times and it has to deliver with NUCIRC input. The troublesome process calculated by the PYTHON program. PYTHON is the script language. The connected python module of the RFSP code and NUCIRC code were developed in order to overcome this disadvantage. The Modeling is CANDU 6 reactor

  20. Empolder and application of LiveWire program

    International Nuclear Information System (INIS)

    Zhang Bo; Li Jing; Wang Xiaoming

    2007-01-01

    LiveWire is a specific module of Netscape Web server to actualize CGI function; through LiveWire application program one can create dynamic web page on web site. This article introduces how to write LiveWire application code, have to compile, debug and manage LiveWire application programs, and how to apply LiveWire application program on Netscape Web server to create a dynamic web page. (authors)

  1. Development and benchmark verification of a parallelized Monte Carlo burnup calculation program MCBMPI

    International Nuclear Information System (INIS)

    Yang Wankui; Liu Yaoguang; Ma Jimin; Yang Xin; Wang Guanbo

    2014-01-01

    MCBMPI, a parallelized burnup calculation program, was developed. The program is modularized. Neutron transport calculation module employs the parallelized MCNP5 program MCNP5MPI, and burnup calculation module employs ORIGEN2, with the MPI parallel zone decomposition strategy. The program system only consists of MCNP5MPI and an interface subroutine. The interface subroutine achieves three main functions, i.e. zone decomposition, nuclide transferring and decaying, data exchanging with MCNP5MPI. Also, the program was verified with the Pressurized Water Reactor (PWR) cell burnup benchmark, the results showed that it's capable to apply the program to burnup calculation of multiple zones, and the computation efficiency could be significantly improved with the development of computer hardware. (authors)

  2. Analysis of dosimetry of a Gamma Knife Perfexion using polystyrene and solid water phantoms for small volume ionization chambers; Analise da dosimetria de um Gamma Knife Perfexion utilizando phantoms de poliestireno e de agua solida para camaras de ionizacao de volume pequeno

    Energy Technology Data Exchange (ETDEWEB)

    Costa, N.A.; Potiens, M.P.A., E-mail: nathaliaac@ymail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Saraiva, C.W.C. [Hospital do Coracao (HCor), Sao Paulo, SP (Brazil); Benmakhlouf, H. [Stockholm University, Karolinska Hospital (Sweden)

    2016-07-01

    The Gamma Knife Perfexion (GKP) is a radiosurgery equipment that has been developed by Elekta. Its dose-rate calibration is performed using phantoms developed by Elekta and a small volume ionization chamber. The purpose of this study was to evaluate the collected charge values obtained in its dosimetry using two different phantoms, polystyrene and solid water and the ion chambers PTW Semiflex, volume 0,125 cm{sup 3}, model 31010 and PTW Pinpoint, volume 0,016 cm{sup 3}, model 31016. (author)

  3. DSNP, Program and Data Library System for Dynamic Simulation of Nuclear Power Plant

    International Nuclear Information System (INIS)

    Saphier, D.; Madell, J.; Dean, E.

    1988-01-01

    1 - Description of problem or function: DSNP (Dynamic Simulator for Nuclear Power-Plants) is a system of programs and data files by which a nuclear power plant, or part thereof, can be simulated. The acronym DSNP is used interchangeably for the DSNP language, the DSNP libraries, the DSNP pre-compiler, and the DSNP document generator. The DSNP language is a special-purpose, block-oriented digital- simulation language developed to facilitate the preparation of dynamic simulations of a large variety of nuclear power plants. It is a user-oriented language that permits the user to prepare simulation programs directly from power plant block diagrams and flow charts by recognizing the symbolic DSNP statements for the appropriate physical components and listing these statements in a logical sequence according to the flow of physical properties in the simulated power plant. Physical components of nuclear power plants are represented by functional blocks, or modules. Many of the more complex components are represented by several modules. The nuclear reactor, for example, has a kinetic module, a power distribution module, a feedback module, a thermodynamic module, a hydraulic module, and a radioactive heat decay module. These modules are stored in DSNP libraries in the form of a DSNP subroutine or function, a block of statements, a macro, or a combination of the above. Basic functional blocks such as integrators, pipes, function generators, connectors, and many auxiliary functions representing properties of materials used in nuclear power plants are also available. The DSNP pre-compiler analyzes the DSNP simulation program, performs the appropriate translations, inserts the requested modules from the library, links these modules together, searches necessary data files, and produces a simulation program in FORTRAN. FORTRAN is considered to be a subset of DSNP and can be inserted anywhere in the simulation program without restriction. I/O statements can be located anywhere in

  4. A Ballistic Limit Analysis Program for Shielding Against Micrometeoroids and Orbital Debris

    Science.gov (United States)

    Ryan, Shannon; Christiansen, Erie

    2010-01-01

    A software program has been developed that enables the user to quickly and simply perform ballistic limit calculations for common spacecraft structures that are subject to hypervelocity impact of micrometeoroid and orbital debris (MMOD) projectiles. This analysis program consists of two core modules: design, and; performance. The design module enables a user to calculate preliminary dimensions of a shield configuration (e.g., thicknesses/areal densities, spacing, etc.) for a ?design? particle (diameter, density, impact velocity, incidence). The performance module enables a more detailed shielding analysis, providing the performance of a user-defined shielding configuration over the range of relevant in-orbit impact conditions.

  5. The NJOY nuclear data processing system: Volume 2, The NJOY, RECONR, BROADR, HEATR, and THERMR modules

    International Nuclear Information System (INIS)

    MacFarlane, R.E.; Muir, D.W.; Boicourt, R.M.

    1982-05-01

    The NJOY nuclear data processing system is a comprehensive computer code package for producing cross sections and related nuclear parameters from ENDF/B evaluated nuclear data. This volume provides detailed descriptions of the NJOY module, which contains the executive program and utility subroutines used by the other modules, and it discusses the theory and computational methods of four of the modules used for producing pointwise cross sections: RECONR, BROADR, HEATR, and THERMR

  6. Fast Convolution Module (Fast Convolution Module)

    National Research Council Canada - National Science Library

    Bierens, L

    1997-01-01

    This report describes the design and realisation of a real-time range azimuth compression module, the so-called 'Fast Convolution Module', based on the fast convolution algorithm developed at TNO-FEL...

  7. A low-cost, hands-on module to characterize antimicrobial compounds using an interdisciplinary, biophysical approach.

    Directory of Open Access Journals (Sweden)

    Karishma S Kaushik

    2015-01-01

    Full Text Available We have developed a hands-on experimental module that combines biology experiments with a physics-based analytical model in order to characterize antimicrobial compounds. To understand antibiotic resistance, participants perform a disc diffusion assay to test the antimicrobial activity of different compounds and then apply a diffusion-based analytical model to gain insights into the behavior of the active antimicrobial component. In our experience, this module was robust, reproducible, and cost-effective, suggesting that it could be implemented in diverse settings such as undergraduate research, STEM (science, technology, engineering, and math camps, school programs, and laboratory training workshops. By providing valuable interdisciplinary research experience in science outreach and education initiatives, this module addresses the paucity of structured training or education programs that integrate diverse scientific fields. Its low-cost requirements make it especially suitable for use in resource-limited settings.

  8. A SiGe Quadrature Pulse Modulator for Superconducting Qubit State Manipulation

    Science.gov (United States)

    Kwende, Randy; Bardin, Joseph

    Manipulation of the quantum states of microwave superconducting qubits typically requires the generation of coherent modulated microwave pulses. While many off-the-shelf instruments are capable of generating such pulses, a more integrated approach is likely required if fault-tolerant quantum computing architectures are to be implemented. In this work, we present progress towards a pulse generator specifically designed to drive superconducing qubits. The device is implemented in a commercial silicon process and has been designed with energy-efficiency and scalability in mind. Pulse generation is carried out using a unique approach in which modulation is applied directly to the in-phase and quadrature components of a carrier signal in the 1-10 GHz frequency range through a unique digital-analog conversion process designed specifically for this application. The prototype pulse generator can be digitally programmed and supports sequencing of pulses with independent amplitude and phase waveforms. These amplitude and phase waveforms can be digitally programmed through a serial programming interface. Detailed performance of the pulse generator at room temperature and 4 K will be presented.

  9. Behavior Tracking Software Enhancement and Integration of a Feedback Module, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Company is proposing to adapt a behavioral tracking program and feedback module specifically developed for the U.S. Army Special Forces for NASA human space...

  10. Thermal modelling of PV module performance under high ambient temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Diarra, D.C.; Harrison, S.J. [Queen' s Univ., Kingston, ON (Canada). Dept. of Mechanical and Materials Engineering Solar Calorimetry Lab; Akuffo, F.O. [Kwame Nkrumah Univ. of Science and Technology, Kumasi (Ghana). Dept. of Mechanical Engineering

    2005-07-01

    When predicting the performance of photovoltaic (PV) generators, the actual performance is typically lower than test results conducted under standard test conditions because the radiant energy absorbed in the module under normal operation raises the temperature of the cell and other multilayer components. The increase in temperature translates to a lower conversion efficiency of the solar cells. In order to address these discrepancies, a thermal model of a characteristic PV module was developed to assess and predict its performance under real field-conditions. The PV module consisted of monocrystalline silicon cells in EVA between a glass cover and a tedlar backing sheet. The EES program was used to compute the equilibrium temperature profile in the PV module. It was shown that heat is dissipated towards the bottom and the top of the module, and that its temperature can be much higher than the ambient temperature. Modelling results indicate that 70-75 per cent of the absorbed solar radiation is dissipated from the solar cells as heat, while 4.7 per cent of the solar energy is absorbed in the glass cover and the EVA. It was also shown that the operating temperature of the PV module decreases with increased wind speed. 2 refs.

  11. The Westinghouse Waste Isolation Division Management and Supervisor Training Program

    International Nuclear Information System (INIS)

    Gilbreath, B.

    1992-01-01

    The Westinghouse Waste Isolation Division (WID) is the management and operating contractor (MOC) for the Department of Energy's (DOE's) Waste Isolation Plant (WIPP). Managers and supervisors at DOE facilities such as the WIPP are required to complete extensive training. To meet this requirement, WID created a self-paced, self-study program known as Management and Supervisor Training (MAST). All WID managers and supervisors are required to earn certification through the MAST program. Selected employees are permitted to participate in MAST with prior approval from their manager and the Human Resources Manager. Initial MAST certification requires the completion of 31 modules. MAST participants check out modules and read them when convenient. When they are prepared, participants take module examinations. To receive credit for a given module, participants must score at least 80 percent on the examination. Lessons learned from the development, implementation, and administration are presented in this paper

  12. Cross-Modulation Interference with Lateralization of Mixed-Modulated Waveforms

    Science.gov (United States)

    Hsieh, I-Hui; Petrosyan, Agavni; Goncalves, Oscar F.; Hickok, Gregory; Saberi, Kourosh

    2010-01-01

    Purpose: This study investigated the ability to use spatial information in mixed-modulated (MM) sounds containing concurrent frequency-modulated (FM) and amplitude-modulated (AM) sounds by exploring patterns of interference when different modulation types originated from different loci as may occur in a multisource acoustic field. Method:…

  13. Analyzing Thermal Module Developments and Trends in High-Power LED

    Directory of Open Access Journals (Sweden)

    Jung-Chang Wang

    2014-01-01

    Full Text Available The solid-state light emitting diode (SSLED has been verified as consumer-electronic products and attracts attention to indoor and outdoor lighting lamp, which has a great benefit in saving energy and environmental protection. However, LED junction temperature will influence the luminous efficiency, spectral color, life cycle, and stability. This study utilizes thermal performance experiments with the illumination-analysis method and window program (vapour chamber thermal module, VCTM V1.0 to investigate and analyze the high-power LED (Hi-LED lighting thermal module, in order to achieve the best solution of the fin parameters under the natural convection. The computing core of the VCTM program employs the theoretical thermal resistance analytical approach with iterative convergence stated in this study to obtain a numerical solution. Results showed that the best geometry of thermal module is 4.4 mm fin thickness, 9.4 mm fin pitch, and 37 mm fin height with the LED junction temperature of 58.8°C. And the experimental thermal resistances are in good agreement with the theoretical thermal resistances; calculating error between measured data and simulation results is no more than ±7%. Thus, the Hi-LED illumination lamp has high life cycle and reliability.

  14. The WIMS-E module W-FORTE

    International Nuclear Information System (INIS)

    Roth, M.J.

    1983-09-01

    There are three distinct versions of the WIMS lattice cell program. WIMS-E is the most general, WIMSD4 is restricted to clusters or to one dimensional slab or annular geometry, and LWRWIMS is designed principally for light water reactor geometries. W-FORTE is used to transfer data from WIMSD4 or LWRWIMS to WIMS-E. A description of the W-FORTE module is given, and includes the relevant data for WIMSD4, LWRWIMS and W-FORTE. (UK)

  15. A user's guide to the reactor containment module NECTAR-SIRKIT

    International Nuclear Information System (INIS)

    Barker, C.D.

    1982-02-01

    The NECTAR environmental computer code has been developed to meet the increasing demand for comprehensive calculations of the radiological consequences of atmospheric releases of radioactivity. The code contains five calculational modules and this report presents a user's guide to the reactor containment module NECTAR-SIRKIT. The mathematical models employed in NECTAR-SIRKIT are briefly described and a complete specification of the input data required by the module is given. These data include facilities for specifying the fuel inventory, the release from irradiated fuel, primary and secondary containment parameters, filtration parameters and commands to identify the lineprinter output required. Three sample test cases are included in an Appendix to demonstrate some of the different ways in which the program may be used and also to provide examples for the prospective user. (author)

  16. Retinoic acid modulates chondrogenesis in the developing mouse cranial base.

    Science.gov (United States)

    Kwon, Hyuk-Jae; Shin, Jeong-Oh; Lee, Jong-Min; Cho, Kyoung-Won; Lee, Min-Jung; Cho, Sung-Won; Jung, Han-Sung

    2011-12-15

    The retinoic acid (RA) signaling pathway is known to play important roles during craniofacial development and skeletogenesis. However, the specific mechanism involving RA in cranial base development has not yet been clearly described. This study investigated how RA modulates endochondral bone development of the cranial base by monitoring the RA receptor RARγ, BMP4, and markers of proliferation, programmed cell death, chondrogenesis, and osteogenesis. We first examined the dynamic morphological and molecular changes in the sphenooccipital synchondrosis-forming region in the mouse embryo cranial bases at E12-E16. In vitro organ cultures employing beads soaked in RA and retinoid-signaling inhibitor citral were compared. In the RA study, the sphenooccipital synchondrosis showed reduced cartilage matrix and lower BMP4 expression while hypertrophic chondrocytes were replaced with proliferating chondrocytes. Retardation of chondrocyte hypertrophy was exhibited in citral-treated specimens, while BMP4 expression was slightly increased and programmed cell death was induced within the sphenooccipital synchondrosis. Our results demonstrate that RA modulates chondrocytes to proliferate, differentiate, or undergo programmed cell death during endochondral bone formation in the developing cranial base. Copyright © 2011 Wiley Periodicals, Inc., A Wiley Company.

  17. Superstability for Generalized Module Left Derivations and Generalized Module Derivations on a Banach Module (I

    Directory of Open Access Journals (Sweden)

    Huai-Xin Cao

    2009-01-01

    Full Text Available We discuss the superstability of generalized module left derivations and generalized module derivations on a Banach module. Let 𝒜 be a Banach algebra and X a Banach 𝒜-module, f:X→X and g:𝒜→𝒜. The mappings Δf,g1, Δf,g2, Δf,g3, and Δf,g4 are defined and it is proved that if ∥Δf,g1(x,y,z,w∥ (resp., ∥Δf,g3(x,y,z,w,α,β∥ is dominated by φ(x,y,z,w, then f is a generalized (resp., linear module-𝒜 left derivation and g is a (resp., linear module-X left derivation. It is also shown that if ∥Δf,g2(x,y,z,w∥ (resp., ∥Δf,g4(x,y,z,w,α,β∥ is dominated by φ(x,y,z,w, then f is a generalized (resp., linear module-𝒜 derivation and g is a (resp., linear module-X derivation.

  18. Improvements in Attention and Cardiac Autonomic Modulation After a 2-Weeks Sprint Interval Training Program: A Fidelity Approach

    Directory of Open Access Journals (Sweden)

    Arilson F. M. de Sousa

    2018-03-01

    Full Text Available This study aimed to: (1 investigate the influence of a 2-weeks sprint interval training (SIT program on aerobic capacity, cardiac autonomic control, and components of attention in young healthy university students; and (2 to ascertain whether training fidelity would influence these adaptations. One hundred and nine participants were divided into an experimental (EG and control (CG groups. The EG performed a SIT program that consisted of 6 sessions of 4 × 30 s “all-out” efforts on a cycle ergometer, interspersed with active rests of 4 min. The criterion for fidelity was achieving >90% of estimated maximum heart rate (HR during sprint bouts. After analyses, the EG was divided into HIGH (n = 26 and LOW (n = 46 fidelity groups. Components of attention were assessed using the Attention Network Test (ANT. Aerobic capacity (VO2max was estimated while the sum of skinfolds was determined. Autonomic control of HR was assessed by means of HR variability (HRV and HR complexity at rest and during ANT. Both HIGH and LOW significantly increased aerobic capacity, vagal modulation before and during ANT, and executive control, and decreased body fatness after SIT (p < 0.05. However, only participants from HIGH showed an increase in HR complexity and accuracy in ANT when compared to LOW (p < 0.05. Two weeks of SIT improved executive control, body fatness, aerobic fitness, and autonomic control in university students with better results reported in those individuals who exhibited high fidelity.

  19. Systems reliability analysis: applications of the SPARCS System-Reliability Assessment Computer Program

    International Nuclear Information System (INIS)

    Locks, M.O.

    1978-01-01

    SPARCS-2 (Simulation Program for Assessing the Reliabilities of Complex Systems, Version 2) is a PL/1 computer program for assessing (establishing interval estimates for) the reliability and the MTBF of a large and complex s-coherent system of any modular configuration. The system can consist of a complex logical assembly of independently failing attribute (binomial-Bernoulli) and time-to-failure (Poisson-exponential) components, without regard to their placement. Alternatively, it can be a configuration of independently failing modules, where each module has either or both attribute and time-to-failure components. SPARCS-2 also has an improved super modularity feature. Modules with minimal-cut unreliabiliy calculations can be mixed with those having minimal-path reliability calculations. All output has been standardized to system reliability or probability of success, regardless of the form in which the input data is presented, and whatever the configuration of modules or elements within modules

  20. A Self-Instructional Course in Student Financial Aid Administration. Module 6: General Student Eligibility. Second Edition.

    Science.gov (United States)

    Washington Consulting Group, Inc., Washington, DC.

    Module 6 of a 17-module self-instructional course on student financial aid administration (for novice aid administrators and other personnel) presents a systematic introduction to the management of federal financial aid programs authorized by Title IV of the Higher Education Act with an emphasis on general student eligibility. Identifying the…

  1. Consideration of adding a commercial module to the International Space Station

    Science.gov (United States)

    Friefeld, J.; Fugleberg, D.; Patel, J.; Subbaraman, G.

    1999-01-01

    The National Aeronautics and Space Administration (NASA) is currently assembling the International Space Station in Low Earth Orbit. One of NASA's program objectives is to encourage space commercialization. Through NASA's Engineering Research and Technology Development program, Boeing is conducting a study to ascertain the feasibility of adding a commercial module to the International Space Station. This module (facility) that can be added, following on-orbit assembly is described. The facility would have the capability to test large, engineering scale payloads in a space environment. It would also have the capability to provide services to co-orbiting space vehicles as well as gathering data for commercial terrestrial applications. The types of industries to be serviced are described as are some of the technical and business considerations that need to be addressed in order to achieve commercial viability.

  2. A range modulator to produce uniform 38K yield

    International Nuclear Information System (INIS)

    Eilbert, R.F.; Koehler, A.M.; Sisterson, J.M.

    1976-01-01

    A range modulator has been designed for use with a monoenergetic proton beam to achieve uniform yield of a nuclear reaction with depth in a tissue equivalent medium. Uniform yield to +- 1.5% over a 10 cm depth for the reaction 40 Ca(p, 2pn) 38 K has been demonstrated using protons of 160 MeV initial energy. The modulator is a rotating stepped absorber made of stacked acrylic plastic sheets. The angular extent of each sheet is determined by a computer program which also calculates the resultant depth of dose curve. Peaks in the dose curve may be reduced with slight effect on the yield curve. (author)

  3. Earth System Science Education Modules

    Science.gov (United States)

    Hall, C.; Kaufman, C.; Humphreys, R. R.; Colgan, M. W.

    2009-12-01

    The College of Charleston is developing several new geoscience-based education modules for integration into the Earth System Science Education Alliance (ESSEA). These three new modules provide opportunities for science and pre-service education students to participate in inquiry-based, data-driven experiences. The three new modules will be discussed in this session. Coastal Crisis is a module that analyzes rapidly changing coastlines and uses technology - remotely sensed data and geographic information systems (GIS) to delineate, understand and monitor changes in coastal environments. The beaches near Charleston, SC are undergoing erosion and therefore are used as examples of rapidly changing coastlines. Students will use real data from NASA, NOAA and other federal agencies in the classroom to study coastal change. Through this case study, learners will acquire remotely sensed images and GIS data sets from online sources, utilize those data sets within Google Earth or other visualization programs, and understand what the data is telling them. Analyzing the data will allow learners to contemplate and make predictions on the impact associated with changing environmental conditions, within the context of a coastal setting. To Drill or Not To Drill is a multidisciplinary problem based module to increase students’ knowledge of problems associated with nonrenewable resource extraction. The controversial topic of drilling in the Arctic National Wildlife Refuge (ANWR) examines whether the economic benefit of the oil extracted from ANWR is worth the social cost of the environmental damage that such extraction may inflict. By attempting to answer this question, learners must balance the interests of preservation with the economic need for oil. The learners are exposed to the difficulties associated with a real world problem that requires trade-off between environmental trust and economic well-being. The Citizen Science module challenges students to translate scientific

  4. Resolving Conflicts: Getting along with Co-Workers. JobLink Winning at Work Instructor's Manual, Module 8.

    Science.gov (United States)

    Coast Community Coll. District, Costa Mesa, CA.

    This manual is a guide to an interactive training program designed to address key skills necessary in today's high performance workplace. The module is intended to meet the learning needs of production workers who may have limited basic skills or literacy. This module, which addresses conflict resolution, focuses on helping employees understand…

  5. Implementation of the Orbital Maneuvering Systems Engine and Thrust Vector Control for the European Service Module

    Science.gov (United States)

    Millard, Jon

    2014-01-01

    The European Space Agency (ESA) has entered into a partnership with the National Aeronautics and Space Administration (NASA) to develop and provide the Service Module (SM) for the Orion Multipurpose Crew Vehicle (MPCV) Program. The European Service Module (ESM) will provide main engine thrust by utilizing the Space Shuttle Program Orbital Maneuvering System Engine (OMS-E). Thrust Vector Control (TVC) of the OMS-E will be provided by the Orbital Maneuvering System (OMS) TVC, also used during the Space Shuttle Program. NASA will be providing the OMS-E and OMS TVC to ESA as Government Furnished Equipment (GFE) to integrate into the ESM. This presentation will describe the OMS-E and OMS TVC and discuss the implementation of the hardware for the ESM.

  6. Module Embedded Micro-inverter Smart Grid Ready Residential Solar Electric System

    Energy Technology Data Exchange (ETDEWEB)

    Agamy, Mohammed [GE Global Research Center, Niskayuna, NY (United States)

    2015-10-27

    The “Module Embedded Micro-inverter Smart Grid Ready Residential Solar Electric System” program is focused on developing innovative concepts for residential photovoltaic (PV) systems with the following objectives: to create an Innovative micro-inverter topology that reduces the cost from the best in class micro-inverter and provides high efficiency (>96% CEC - California Energy Commission), and 25+ year warranty, as well as reactive power support; integrate micro-inverter and PV module to reduce system price by at least $0.25/W through a) accentuating dual use of the module metal frame as a large area heat spreader reducing operating temperature, and b) eliminating redundant wiring and connectors; and create micro-inverter controller handles smart grid and safety functions to simplify implementation and reduce cost.

  7. Broadband demonstrations of true-time delay using linear sideband chirped programming and optical coherent transients

    International Nuclear Information System (INIS)

    Reibel, R.R.; Barber, Z.W.; Fischer, J.A.; Tian, M.; Babbitt, W.R.

    2004-01-01

    Linear sideband chirped (LSC) programming is introduced as a means of configuring spatial-spectral holographic gratings for optical coherent transient processors. Similar to linear frequency chirped programming, LSC programming allows the use of broadband integrated electro-optic phase modulators to produce chirps instead of using elaborate broadband chirped lasers. This approach has several advantages including the ability to use a stabilized laser for the optical carrier as well as stable, reproducible chirped optical signals when the modulator is driven digitally. Using LSC programming, we experimentally demonstrate broadband true-time delay as a proof of principle for the optical control of phased array radars. Here both cw phase modulated and binary phase shift keyed probe signals are true-time delayed with bandwidths of 1 GHz and delay resolutions better than 60 ps

  8. Modular space station, phase B extension. Program operations plan

    Science.gov (United States)

    1971-01-01

    An organized approach is defined for establishing the most significant requirements pertaining to mission operations, information management, and computer program design and development for the modular space station program. The operations plan pertains to the space station and experiment module program elements and to the ground elements required for mission management and mission support operations.

  9. Photovoltaic module certification/laboratory accreditation criteria development: Implementation handbook

    Energy Technology Data Exchange (ETDEWEB)

    Osterwald, C.R. [National Renewable Energy Laboratory, Golden, CO (United States); Hammond, R.L.; Wood, B.D.; Backus, C.E.; Sears, R.L. [Arizona State Univ., Tempe, AZ (United States); Zerlaut, G.A. [SC-International, Inc., Tempe, AZ (United States); D`Aiello, R.V. [RD Associates, Tempe, AZ (United States)

    1996-08-01

    This document covers the second phase of a two-part program. Phase I provided an overview of the structure and function of typical product certification/laboratory accreditation programs. This report (Phase H) provides most of the draft documents that will be necessary for the implementation of a photovoltaic (PV) module certification/laboratory accreditation program. These include organizational documents such as articles of incorporation, bylaws, and rules of procedure, as well as marketing and educational program documents. In Phase I, a 30-member criteria development committee was established to guide, review and reach a majority consensus regarding criteria for a PV certification/laboratory accreditation program. Committee members represented PV manufacturers, end users, standards and codes organizations, and testing laboratories. A similar committee was established for Phase II; the criteria implementation committee consisted of 29 members. Twenty-one of the Phase I committee members also served on the Phase II committee, which helped to provide program continuity during Phase II.

  10. Meningkatkan Kemandirian Belajar dan Hasil Belajar Siswa melalui Pengembangan Modul Administrasi Kepegawaian Berbasis Strategi Pembelajaran Inkuiri Terbimbing

    Directory of Open Access Journals (Sweden)

    Kharisma Swandhana

    2016-11-01

    Full Text Available Abstract: This research and development aimed to produce a module of Employee Administration based on Guided Inquiry Learning Strategy for the twelfth grade students of Office Administration program, to determine the feasibility of the module developed through validation, and to know whether there is an improvement towards independent learning and students’ ourcomes before and after using the module This research and development used 4D model. It consisted of 4 stages of development: define, design, develop, and disseminate. It was obtained the average sore of post-test 91.76 in the experimental class, and the results of material and module validation reached 90.66% and 88.30%.  The result of questionnaire distribution of independent learning using the module showed 90%. Thus, from the results of this research showed that the Employee Administration module was applicable and able to improve independent learning and students’ outcomes. It was suggested to use this module as a supporting alternative for learning Employee Administration, specifically on material of discharging employees and pension. ABSTRAK: Penelitian dan pengembangan ini bertujuan untuk menghasilkan bahan ajar berupa Modul Administrasi Kepegawaian Berbasis Strategi Pembelajaran Inkuiri Terbimbing untuk siswa SMK kelas XII Program Keahlian Administrasi Perkantoran., mengetahui kelayakan modul yang telah dikembangkan melalui hasil validasi, dan mengetahui apakah terjadi peningkatan kemandirian belajar dan hasil belajar siswa sebelum dan sesudah menggunakan modul. Penelitian dan pengembangan ini dilakukan dengan menggunakan 4D model. Model ini terdiri dari 4 tahap pengembangan, yaitu define, design, develop, dan disseminate. Diperoleh hasil rata rata nilai post test 91,76 pada kelas eksperimen, hasil validasi oleh ahli materi dan ahli modul mencapai hasil 90,66% dan 88,30%, hasil penyebaran angket kemandirian belajar siswa dengan menggunakan modul juga mencapai persentase 90

  11. Development of Automated Production Line Processes for Solar Brightfield Modules: Annual Technical Progress Report, 1 January 2003 -- 30 June 2004

    Energy Technology Data Exchange (ETDEWEB)

    Nowlan, M. J.; Murach, J. M.; Sutherland, S. F.; Miller, D. C.; Moore, S. B.; Hogan, S. J.

    2005-06-01

    This report describes how Spire Corporation is addressing the PV Manufacturing R&D project goals of improving photovoltaic (PV) manufacturing processes and products while reducing costs and providing a technology foundation that supports significant manufacturing scale-up. To accomplish this, we are focusing our efforts on the design of a large-area utility-scale module and the development of the necessary manufacturing techniques and equipment to manufacture such a module in a high-volume production environment. A three-phase program is under way for developing and demonstrating new automated systems for fabricating very large PV modules ideal for use in multi-megawatt grid-connected applications. We designed a large-area 800 W module and we are developing associated module production equipment that will minimize the total installed system cost for utility-scale PV arrays. Unique features of the module design include a cantilevered glass superstrate to reduce the glass thickness a nd internally laminated bypass diodes that simplify internal busing and junction-box designs. Other program activities include the development of automation for solar cell string inspections, string busing, materials lay-up, and lamination; enhancements to the lamination process; and performance testing of large-area modules.

  12. Tune shift and betatron modulations due to insertion devices in SPEAR

    International Nuclear Information System (INIS)

    Corbett, W.J.

    1989-12-01

    SPEAR will soon operate as a dedicated synchrotron radiation source with up to 5 beamlines fed from insertion devices. These magnets introduce additional focusing forces into the storage ring lattice which increase the vertical betatron tune and modulate the beam envelope in the vertical plane. The lattice simulation code 'GEMINI' is used to evaluate the tune shifts and estimate the degree of betatron modulation as each magnetic insertion device is brought up to full power. A program is recommended to correct the tunes with the FODO cell quadrupoles. 4 refs., 8 figs., 1 tab

  13. Organization of a library of standard relocatible programmes, or a processing measurement data module based on computers of the TRA types

    International Nuclear Information System (INIS)

    Dadi, K.; Dadi, L.; Mateeva, A.; Salamatin, I.M.

    1976-01-01

    The paper describes the organization of a library of standard programs with binary cade. The library was developed for a measurement module on the basis of a TRA-1001-i computer (Elektronika-100, PDP-8). The library is placed on a external memory (magnetic disk) and has a module structure. The external memory assigned for the library is divided into pages. When loaded into the computer internal memory, several pages are taken as one whole to represent the loading module. The magnetic disk storage capacity being 1.25 million words, the library has a total of ca. 50 10 thousand words (eight cylinders). The work provides regulations for compiling standard programs in SLANG. The library is characterized by the following main features: possibility of being used in memory dynamic distribution mode; possibility of being used for computers with internal memory capacity 4K; no need for intermediary-language coding of displaced program; and possibility of autonomous shift of standard program. The above library is compared with a comprising DES programs library

  14. Design and development of CAMAC 12 bit ADC/DAC dual purpose module

    International Nuclear Information System (INIS)

    Kulkarni, S.G.; Gore, J.A.; Ramlal, V.; Matkar, U.V.; Lokare, R.N.; Yadav, M.L.; Ekambaram, M.; Gupta, A.K.; Datar, V.M.

    2013-01-01

    A dual function CAMAC module is designed for Pelletron Accelerator which can function as 12 bit 8 channels DAC or 12 bit 16 channels ADC. Spartan 2 series of FPGA is used for implementing the CAMAC interface logic as well as logic for ADC/DAC interface. The PCB has both the ADC and DAC mounted but the module can have only one function selected due to wiring constraint. Two different VHDL programs (one for the ADC and other for the DAC) reside on the EEPROM permitting selection of any one as per the functionality required. The module is working as a 12 bit DAC at BARC-TIFR Pelletron Linac Facility, successfully. (author)

  15. Development Strategies for Online Volunteer Training Modules: A Team Approach

    Science.gov (United States)

    Robideau, Kari; Vogel, Eric

    2014-01-01

    Volunteers are central to the delivery of 4-H programs, and providing quality, relevant training is key to volunteer success. Online, asynchronous modules are an enhancement to a training delivery menu for adult volunteers, providing consistent, accessible options traditionally delivered primarily face to face. This article describes how Minnesota…

  16. Modelling modulation perception : modulation low-pass filter or modulation filter bank?

    NARCIS (Netherlands)

    Dau, T.; Kollmeier, B.; Kohlrausch, A.G.

    1995-01-01

    In current models of modulation perception, the stimuli are first filtered and nonlinearly transformed (mostly half-wave rectified). In order to model the low-pass characteristic of measured modulation transfer functions, the next stage in the models is a first-order low-pass filter with a typical

  17. RIPE [robot independent programming environment]: A robot independent programming environment

    International Nuclear Information System (INIS)

    Miller, D.J.; Lennox, R.C.

    1990-01-01

    Remote manual operations in radiation environments are typically performed very slowly. Sensor-based computer-controlled robots hold great promise for increasing the speed and safety of remote operations; however, the programming of robotic systems has proven to be expensive and difficult. Generalized approaches to robot programming that reuse available software modules and employ programming languages which are independent of the specific robotic and sensory devices being used are needed to speed software development and increase overall system reliability. This paper discusses the robot independent programming environment (RIPE) developed at Sandia National Laboratories (SNL). The RIPE is an object-oriented approach to robot system architectures; it is a software environment that facilitates rapid design and implementation of complex robot systems for diverse applications. An architecture based on hierarchies of distributed multiprocessors provides the computing platform for a layered programming structure that models applications using software objects. These objects are designed to support model-based automated programming of robotic and machining devices, real-time sensor-based control, error handling, and robust communication

  18. A Self-Instructional Course in Student Financial Aid Administration. Module 7: Calculating Cost of Attendance. Second Edition.

    Science.gov (United States)

    Washington Consulting Group, Inc., Washington, DC.

    The seventh module in a 17-module self-instructional course on student financial aid administration (designed for novice student financial aid administrators and other personnel) teaches how to calculate the cost of attendance. It provides a systematic introduction to the management of federal financial aid programs authorized by the Higher…

  19. Automated identification of RNA 3D modules with discriminative power in RNA structural alignments

    DEFF Research Database (Denmark)

    Theis, Corinna; Höner zu Siederdissen, Christian; Hofacker, Ivo L.

    2013-01-01

    Recent progress in predicting RNA structure is moving towards filling the 'gap' in 2D RNA structure prediction where, for example, predicted internal loops often form non-canonical base pairs. This is increasingly recognized with the steady increase of known RNA 3D modules. There is a general...... comparative evidence. Subsequently, the modules, initially represented by a graph, are turned into models for the RMDetect program, which allows to test their discriminative power using real and randomized Rfam alignments. An initial extraction of 22495 3D modules in all PDB files results in 977 internal loop...

  20. RSYST - a short description of the modules

    International Nuclear Information System (INIS)

    Ruehle, R.

    1976-04-01

    The modular system RSYST is used for reactor and shielding calculations. A data base managed by a central program, data blocks containing structure descriptions, and hierarchical linking of data blocks enable flexible management of all data. Module sequences are formulated using a user command language. The language features logical branches, variables and arithmetic experssions. Sections of the user language may be stored in the data base and activated at any time. (orig.) [de

  1. Electromagnetic analysis of transient disruption forces on the ITER shield modules

    International Nuclear Information System (INIS)

    Kotulski, J.D.; Coats, R.S.; Pasik, M.F.

    2007-01-01

    There are potential abnormal operating environments where the disruption of the plasma currents inside a tokamak induce eddy currents in the shield modules. These currents interact with the large magnetic fields to produce forces in the modules which could potentially cause mechanical failure in the modules and vacuum vessel. For this reason the design and qualification of the ITER shield modules requires appropriate high-fidelity electromagnetic simulations that capture the physics of these situations. These simulations need to include an accurate representation of the disruption currents as well as an accurate electromagnetic model of the shield modules. The purpose of this presentation is to describe the electromagnetic analysis that has been completed using the OPERA-3D product to characterize the forces on the shield modules allocated to the US. We first describe the electromagnetic model of the system which consists of the disruption currents and the shield modules attached to the vacuum vessel. The disruption currents are represented in OPERA-3D using superposition of a large number of solenoids with independent time variation to account for the spatial and temporal variation of the plasma current and position. In addition, the simplified electromagnetic model of the shield modules will be described and discussed. Once the modeling has been described the simulation results are presented. The force computation are also presented and the results discussed. These forces are then used by a mechanical analysis program to compute stresses and torques on a module during the disruption of the plasma currents. (orig.)

  2. Liquid metal blanket module testing and design for ITER/TIBER II

    International Nuclear Information System (INIS)

    Mattas, R.F.; Cha, Y.; Finn, P.A.; Majumdar, S.; Picologlou, B.; Stevens, H.; Turner, L.

    1988-05-01

    A major goal for ITER is the testing of nuclear components to demonstrate the integrated performance of the most attractive concepts that can lead to a commercial fusion reactor. As part of the ITER/TIBER II study, the test program and design of test models were examined for a number of blanket concepts. The work at Argonne National Laboratory focused on self-cooled liquid metal blankets. A test program for liquid metal blankets was developed based upon the ITER/TIBER II operating schedule and the specific data needs to resolve the key issues for liquid metals. Testing can begin early in reactor operation with liquid metal MHD tests to confirm predictive capability. Combined heat transfer/MHD tests can be performed during initial plasma operation. After acceptable heat transfer performance is verified, tests to determine the integrated high temperature performance in a neutron environment can begin. During the high availability phase operation, long term performance and reliability tests will be performed. It is envisioned that a companion test program will be conducted outside ITER to determine behavior under severe accident conditions and upper performance limits. A detailed design of a liquid metal test module and auxiliary equipment was also developed. The module followed the design of the TPSS blanket. Detailed analysis of the heat transfer and tritium systems were performed, and the overall layout of the systems was determined. In general, the blanket module appears to be capable of addressing most of the testing needs. 8 refs., 27 figs., 11 tabs

  3. Apparel Research Network (ARN) Apparel Order Processing Module (AOPM). Application Program for Management of Special Measurement Clothing Orders

    Science.gov (United States)

    1997-09-30

    Screen, abandoning changes. APPAREL ORDER PROCESSING MODULE FIELD USER MANUAL Ordering Official Screens The Ordering Official Screens are provided for...currendy selected Ordering Official will appear on the Ordering Official Information Screen. APPAREL ORDER PROCESSING MODULE FIELD USER MANUAL Ordering Official

  4. BACHELOR OF INFORMATICS COMPETENCE IN PROGRAMMING

    Directory of Open Access Journals (Sweden)

    Andrii M. Striuk

    2015-04-01

    Full Text Available Based on the analysis of approaches to the definition of professional competencies of IT students the competence in programming of bachelor of informatics is proposed. Due to the standard of training in 040302 “Informatics” and Computing Curricula 2001 it was defined the content and structure of the competence in programming of bachelor of informatics. The system of content modules providing its formation was designed. The contribution of regulatory competencies of bachelor of informatics in the formation of competence in programming is defined. The directions of formation of competence in programming in the cloudy-oriented learning environment are proposed.

  5. Super-resolution with an optically-addressable liquid crystal spatial light modulator

    International Nuclear Information System (INIS)

    McOrist, J.; Sharma, M.D.; Sheppard, C.J.R.

    2002-01-01

    Full text: An optically-addressable liquid crystal spatial light modulator has been used to generate super-resolving masks. This approach avoids problems of low efficiency and coupling between amplitude and phase modulation, that occur when using conventional liquid crystal modulators. When addressed by a programmed light intensity distribution, it allows filters to be changed rapidly to modify the response of a system or permit the investigation of different filter designs. The device used is not pixellated, with a spatial resolution of 30 line pairs/mm over an area 18mm X 18mm, and can achieve continuously-variable phase modulation up to 1.5 wavelengths. The system consists of a write-beam that is collimated from a white-light source. An input mask was used in our experiments determines the modulation pattern of the read-beam. The read-beam from a HeNe laser reflects from the modulator and is focused by a microscope objective. The value of the phase change induced by the transparent regions of the mask can be altered continuously by adjusting the brightness of the write-beam. We have used this system to attain super-resolution by simple Toraldo filters, consisting of arrays of rings. Copyright (2002) Australian Society for Electron Microscopy Inc

  6. E-Basics: Online Basic Training in Program Evaluation

    Science.gov (United States)

    Silliman, Ben

    2016-01-01

    E-Basics is an online training in program evaluation concepts and skills designed for youth development professionals, especially those working in nonformal science education. Ten hours of online training in seven modules is designed to prepare participants for mentoring and applied practice, mastery, and/or team leadership in program evaluation.…

  7. An electro-optic spatial light modulator for thermoelastic generation of programmably focused ultrasound

    Science.gov (United States)

    1984-12-01

    The concept proposed is an electro-optic technique that would make it possible to spatially modulate a high power pulsed laser beam to thermoelastically induce focused ultrasound in a test material. Being a purely electro-optic device, the modulator, and therefore the depth at which the acoustic focus occurs, can be programmed electronically at electronic speeds. If successful, it would become possible to scan ultrasound continuously in three dimensions within the component or structure under test.

  8. Development of the French Photovoltaic Program

    Energy Technology Data Exchange (ETDEWEB)

    Brunet, M.

    1980-07-01

    The French photovoltaic research program is reviewed, listing companies involved. Projections of module and system costs are discussed. French industrial experience in photovoltaics is reviewed and several French systems operating in developing countries are mentioned. (MHR)

  9. Security Injections 2.0: Increasing Engagement and Faculty Adoption Using Enhanced Secure Coding Modules for Lower-Level Programming Courses

    OpenAIRE

    Raina , Sagar; Taylor , Blair; Kaza , Siddharth

    2015-01-01

    Part 2: Software Security Education; International audience; Learning interventions based on modules are common in computer science education. Traditional learning modules that present a large amount of content in a linear format can lead to students skimming and skipping content resulting in lower student engagement and effectiveness. In this paper, we present theoretical support for increasing engagement and effectiveness of learning modules, describe a system that implements these principl...

  10. Mutually-modulated cross-gain modulation and slow light

    International Nuclear Information System (INIS)

    Sternklar, Shmuel; Sarid, Eyal; Wart, Maxim; Granot, Er'el

    2010-01-01

    The interaction of pump and Stokes light in a Brillouin medium, where both beams are modulated, can be utilized for controlling the group velocity of the amplified Stokes (or depleted pump). The dependence of the group velocity for this mutually-modulated cross-gain modulation (MMXGM) technique on the Brillouin gain parameter is studied. A sharp transition to slow light occurs in the G 1 α/β≈1 regime, where G 1 is the Brillouin gain parameter, and α and β are the pump and Stokes modulation indices, respectively. A comparison of MMXGM slow light to the Brillouin dispersion-based slow-light technique reveals the fundamental differences between them. The formation of higher harmonics of the modulation frequency is also discussed. The theoretical predictions are experimentally corroborated and potential applications in fiber-based sensing and interferometry are discussed

  11. Design and Implementation of a Mechatronics Learning Module in a Large First-Semester Engineering Course

    Science.gov (United States)

    Castles, R. T.; Zephirin, T.; Lohani, V. K.; Kachroo, P.

    2010-01-01

    Since 2005, the first-year engineering program at Virginia Tech, Blacksburg, has been significantly restructured to include more hands-on learning. A major grant (2004-2009) under the department level reform (DLR) program of the National Science Foundation (NSF) facilitated this restructuring. A number of hands-on learning modules were developed…

  12. Dual-arm manipulation module for use in decontamination and decommissioning operations

    International Nuclear Information System (INIS)

    Hamel, W.R.; Haley, D.C.; Dixon, W.E.

    1994-01-01

    A dual-arm manipulation module is under development for application in decontamination and decommissioning (D ampersand D) tasks. The development is led by Oak Ridge National Laboratory with support from Sandia National Laboratories, and with university and industry participation. The project is part of the Robotics Technology Development Program funded by the US Department of Energy, Environmental Restoration and Waste Management, Office of Technology Development. The dual-arm module is designed to provide dexterous manipulation capability for remote characterization, decontamination, and dismantlement operations, and the module is reconfigurable to meet various deployment requirements. Remote manipulation capability can benefit D ampersand D activities through reduced worker exposure to both contaminant and industrial hazards. When tasks conditions permit, increased use of robotic features reduce costs by increased efficiency of operation

  13. SU-E-T-634: Pre-Verification of FFF Prostate VMAT Plans with Gamma Method and DVHs Reconstructed Based On Measurements with 2D-ARRAY (PTW 1500) and OCTAVIUS 4D

    Energy Technology Data Exchange (ETDEWEB)

    Kruszyna, M; Adamczyk, M

    2015-06-15

    Purpose: The aim of this work was to characterize the clinical correctness of FFF prostate treatment VMAT plans based on analysis of DVHs reconstructed from pre-verification 2D-arrays measurements. Methods: The new 2D ion chamber array 1500 with rotational phantom cylindrical Octavius 4D and Verisoft 6.1 software with DVH option (PTW, Freiburg) were used to determine the clinical usefulness of the treatment plans. Ten patients treated with VMAT high-fractionated (2 fraction x 7,5 Gy) FFF prostate plans (TrueBeam, Varian) were analyzed using the 3D gamma analysis by local dose method with a 5% threshold for various tolerance parameters DTA [mm] and DD [%] were 1%/1, 2%/2, 3%/3. Additional, based on the measurements of irradiation dose distributions and patients’ CT scans with contoured structures of organs, the DVHs were reconstructed using a software. The obtained DVHs were compared to planned dose distributions and the deviations were analysed with parameters: for CTV D50, D98, D2, and D25, D50, Dmax for OARs — rectum, bladder and left/right femoral heads. Results: The analyzed treatment plans passed gamma criteria (3/3%; 95%), the results obtained were as follow: mean value and standard deviation of gamma score for criteria (DTA[mm]/DD[%]): 1/1% (L53.3±3.2); 2/2% (L87.0±2.2); 3/3% (L97.5±0.9). In the DVH analysis, the highest differences were observed for OARs (especially for bladder): the mean percentage differences values for rectum, bladder and left/right femoral heads were: D25 (1.67; 6.83)%, D50 (0.18; 7.18; 1.53; 0.30)%, Dmax (−0.84; −1.64; 0.37; −4.63)%, respectively. For the CTV mean relative deviations for proper parameters were in good agreement with TPS: D98 (0.95±2.21)%, D50 (1.93±0.67)%, D2 (1.76±0.76)%. Conclusion: The gamma method is recommended tool for pre-verification analysis of correctness of treatment plans. Moreover, the scrutiny checking with reconstructed DVH gives additional, clinical information about quality of plan

  14. GAMSOURCE - WRS system module number 38474 for calculating gamma-ray sources produced by neutron capture

    International Nuclear Information System (INIS)

    Grimstone, M.J.

    1978-06-01

    The WRS Modular Programming System has been developed as a means by which programmes may be more efficiently constructed, maintained and modified. In this system a module is a self-contained unit typically composed of one or more Fortran routines, and a programme is constructed from a number of such modules. This report describes one WRS module, the function of which is to calculate the source strength of gamma-rays arising from neutron capture in a system represented in one-dimensional geometry. The information given in this manual is of use both to the programmer wishing to incorporate the module in a programme, and to the user of such a programme. (author)

  15. Development of a Virtual Crew Resource Management Training Program to Improve Communication.

    Science.gov (United States)

    Tschannen, Dana

    2017-11-01

    Crew Resource Management (CRM), a method focused on the management of human error and risk reduction, has shown promise in reducing communication failure in health care. The purpose of this project was to develop a virtual training program in CRM principles of effective leadership and followership, and evaluate the applicability to nurses working in the hospital setting. The intervention included the development of a virtual CRM training program consisting of a self-learning module and virtual simulation. Beta testing of the module was conducted by six nurses, followed by an evaluation of the training program by nurses (n = 5) in a general medicine department. Nurses reported the overall program to be worthwhile (X̄= 5; SD = 0.5), with great applicability to nursing care (X̄= 4.5, SD = 0.5). Nurses completing the simulation activity reported strong agreement to CRM applicability and training effectiveness. The CRM training module proved to be applicable to nursing care and is ready for widespread use to improve patient care and communication. J Contin Educ Nurs. 2017;48(11):525-532. Copyright 2017, SLACK Incorporated.

  16. Refurbishment programs

    International Nuclear Information System (INIS)

    Irish, C.S.

    2004-01-01

    As nuclear plants age, equipment becomes obsolete, outdated or just simply unreliable. This puts a lot of emphasis on replacement of the subject equipment. This can be an expensive proposition for safety related equipment due to design changes, requalification charges and the cost of the new equipment, specifically when the original component is obsolete. The presentation will explain how comprehensive refurbishment programs on many different types of equipment can alleviate this situation. The refurbishment program is a systematic refurbishment of equipment to an as new condition by replacing all of the age sensitive components within the equipment. This is carried out on all of the same type of equipment in a scheduled program. For example the plant may to decide to refurbish all of their Lambda LME-24 power supplies, or all of their Bailey modules, or all of their Agastat DSC Series relays. Independent of the item the process is the same. Refurbish each piece of equipment to an as new condition by replacing all of the age sensitive equipment. The equipment is then returned to the client as safety related, existing qualification maintained and with a new service life/warranty. This is not a simple repair. It is a planned refurbishment to an as new condition of certain equipment types throughout the plant and then carried out from equipment piece to equipment piece. The refurbishment program may even include introducing new spares into the plant. This is normally performed by upgrading (dedicating for safety related use and refurbishing to an 'as new' condition) surplus equipment and using these equipment pieces in the rotation of the plant equipment to refurbish the entire population of a selected piece of equipment at the plant. This process can be performed on many equipment types including power supplies, circuit boards, modules, relays, motors, breakers, and many more. The refurbishment program greatly increases the reliability of the equipment without the

  17. Electroabsorption optical modulator

    Energy Technology Data Exchange (ETDEWEB)

    Skogen, Erik J.

    2017-11-21

    An electroabsorption modulator incorporates waveguiding regions along the length of the modulator that include quantum wells where at least two of the regions have quantum wells with different bandgaps. In one embodiment of the invention, the regions are arranged such that the quantum wells have bandgaps with decreasing bandgap energy along the length of the modulator from the modulator's input to its output. The bandgap energy of the quantum wells may be decreased in discrete steps or continuously. Advantageously, such an arrangement better distributes the optical absorption as well as the carrier density along the length of the modulator. Further advantageously, the modulator may handle increased optical power as compared with prior art modulators of similar dimensions, which allows for improved link gain when the optical modulator is used in an analog optical communication link.

  18. Computational exploration of cis-regulatory modules in rhythmic expression data using the "Exploration of Distinctive CREs and CRMs" (EDCC) and "CRM Network Generator" (CNG) programs.

    Science.gov (United States)

    Bekiaris, Pavlos Stephanos; Tekath, Tobias; Staiger, Dorothee; Danisman, Selahattin

    2018-01-01

    Understanding the effect of cis-regulatory elements (CRE) and clusters of CREs, which are called cis-regulatory modules (CRM), in eukaryotic gene expression is a challenge of computational biology. We developed two programs that allow simple, fast and reliable analysis of candidate CREs and CRMs that may affect specific gene expression and that determine positional features between individual CREs within a CRM. The first program, "Exploration of Distinctive CREs and CRMs" (EDCC), correlates candidate CREs and CRMs with specific gene expression patterns. For pairs of CREs, EDCC also determines positional preferences of the single CREs in relation to each other and to the transcriptional start site. The second program, "CRM Network Generator" (CNG), prioritizes these positional preferences using a neural network and thus allows unbiased rating of the positional preferences that were determined by EDCC. We tested these programs with data from a microarray study of circadian gene expression in Arabidopsis thaliana. Analyzing more than 1.5 million pairwise CRE combinations, we found 22 candidate combinations, of which several contained known clock promoter elements together with elements that had not been identified as relevant to circadian gene expression before. CNG analysis further identified positional preferences of these CRE pairs, hinting at positional information that may be relevant for circadian gene expression. Future wet lab experiments will have to determine which of these combinations confer daytime specific circadian gene expression.

  19. Processing module operating methods, processing modules, and communications systems

    Science.gov (United States)

    McCown, Steven Harvey; Derr, Kurt W.; Moore, Troy

    2014-09-09

    A processing module operating method includes using a processing module physically connected to a wireless communications device, requesting that the wireless communications device retrieve encrypted code from a web site and receiving the encrypted code from the wireless communications device. The wireless communications device is unable to decrypt the encrypted code. The method further includes using the processing module, decrypting the encrypted code, executing the decrypted code, and preventing the wireless communications device from accessing the decrypted code. Another processing module operating method includes using a processing module physically connected to a host device, executing an application within the processing module, allowing the application to exchange user interaction data communicated using a user interface of the host device with the host device, and allowing the application to use the host device as a communications device for exchanging information with a remote device distinct from the host device.

  20. Practical Maya programming with Python

    CERN Document Server

    Galanakis, Robert

    2014-01-01

    ""Practical Maya Programming with Python"" is a practical tutorial packed with plenty of examples and sample projects which guides you through building reusable, independent modules and handling unexpected errors. If you are a developer looking to build a powerful system using Python and Maya's capabilities, then this book is for you. Practical Maya Programming with Python is perfect for intermediate users with basic experience in Python and Maya who want to better their knowledge and skills.

  1. SU-F-T-367: Using PRIMO, a PENELOPE-Based Software, to Improve the Small Field Dosimetry of Linear Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Benmakhlouf, H; Andreo, P [Department of Medical Physics, Karolinska University Hospital (Sweden); Brualla, L [NCTeam, Strahlenklinik, Universitatsklinikum Essen (Germany); Sempau, J [Institut de Tecniques Energetiques, Universitat Politecnica de Catalunya (Spain)

    2016-06-15

    Purpose: To calculate output correction factors for Varian Clinac 2100iX beams for seven small field detectors and use the values to determine the small field output factors for the linacs at Karolinska university hospital. Methods: Phase space files (psf) for square fields between 0.25cm and 10cm were calculated using the PENELOPE-based PRIMO software. The linac MC-model was tuned by comparing PRIMO-estimated and experimentally determined depth doses and lateral dose-profiles for 40cmx40cm fields. The calculated psf were used as radiation sources to calculate the correction factors of IBA and PTW detectors with the code penEasy/PENELOPE. Results: The optimal tuning parameters of the MClinac model in PRIMO were 5.4 MeV incident electron energy and zero energy spread, focal spot size and beam divergence. Correction factors obtained for the liquid ion chamber (PTW-T31018) are within 1% down to 0.5 cm fields. For unshielded diodes (IBA-EFD, IBA-SFD, PTW-T60017 and PTW-T60018) the corrections are up to 2% at intermediate fields (>1cm side), becoming down to −11% for fields smaller than 1cm. The shielded diode (IBA-PFD and PTW-T60016) corrections vary with field size from 0 to −4%. Volume averaging effects are found for most detectors in the presence of 0.25cm fields. Conclusion: Good agreement was found between correction factors based on PRIMO-generated psf and those from other publications. The calculated factors will be implemented in output factor measurements (using several detectors) in the clinic. PRIMO is a userfriendly general code capable of generating small field psf and can be used without having to code own linac geometries. It can therefore be used to improve the clinical dosimetry, especially in the commissioning of linear accelerators. Important dosimetry data, such as dose-profiles and output factors can be determined more accurately for a specific machine, geometry and setup by using PRIMO and having a MC-model of the detector used.

  2. Teaching OM at an Action-based Learning Program for Top Executives

    DEFF Research Database (Denmark)

    Perunovic, Zoran; Staffensen, Lasse

    2013-01-01

    The paper discusses design and execution of OM module in an intensive program for top executives. The participants are working as consultants in six different host companies on developing growth strategies. The OM module is designed to enable the participants to develop operations strategy that s...

  3. PLC/DTAM Software Programs for Pumping Instrumentation and Control Skid ''L''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''L''. The Appendices contains copies of the printouts of these software programs

  4. Photovoltaic module reliability improvement through application testing and failure analysis

    Science.gov (United States)

    Dumas, L. N.; Shumka, A.

    1982-01-01

    During the first four years of the U.S. Department of Energy (DOE) National Photovoltatic Program, the Jet Propulsion Laboratory Low-Cost Solar Array (LSA) Project purchased about 400 kW of photovoltaic modules for test and experiments. In order to identify, report, and analyze test and operational problems with the Block Procurement modules, a problem/failure reporting and analysis system was implemented by the LSA Project with the main purpose of providing manufacturers with feedback from test and field experience needed for the improvement of product performance and reliability. A description of the more significant types of failures is presented, taking into account interconnects, cracked cells, dielectric breakdown, delamination, and corrosion. Current design practices and reliability evaluations are also discussed. The conducted evaluation indicates that current module designs incorporate damage-resistant and fault-tolerant features which address field failure mechanisms observed to date.

  5. COMET Multimedia modules and objects in the digital library system

    Science.gov (United States)

    Spangler, T. C.; Lamos, J. P.

    2003-12-01

    Over the past ten years of developing Web- and CD-ROM-based training materials, the Cooperative Program for Operational Meteorology, Education and Training (COMET) has created a unique archive of almost 10,000 multimedia objects and some 50 web based interactive multimedia modules on various aspects of weather and weather forecasting. These objects and modules, containing illustrations, photographs, animations,video sequences, audio files, are potentially a valuable resource for university faculty and students, forecasters, emergency managers, public school educators, and other individuals and groups needing such materials for educational use. The COMET Modules are available on the COMET educational web site http://www.meted.ucar.edu, and the COMET Multimedia Database (MMDB) makes a collection of the multimedia objects available in a searchable online database for viewing and download over the Internet. Some 3200 objects are already available at the MMDB Website: http://archive.comet.ucar.edu/moria/

  6. An Effective Model of the Retinoic Acid Induced HL-60 Differentiation Program.

    Science.gov (United States)

    Tasseff, Ryan; Jensen, Holly A; Congleton, Johanna; Dai, David; Rogers, Katharine V; Sagar, Adithya; Bunaciu, Rodica P; Yen, Andrew; Varner, Jeffrey D

    2017-10-30

    In this study, we present an effective model All-Trans Retinoic Acid (ATRA)-induced differentiation of HL-60 cells. The model describes reinforcing feedback between an ATRA-inducible signalsome complex involving many proteins including Vav1, a guanine nucleotide exchange factor, and the activation of the mitogen activated protein kinase (MAPK) cascade. We decomposed the effective model into three modules; a signal initiation module that sensed and transformed an ATRA signal into program activation signals; a signal integration module that controlled the expression of upstream transcription factors; and a phenotype module which encoded the expression of functional differentiation markers from the ATRA-inducible transcription factors. We identified an ensemble of effective model parameters using measurements taken from ATRA-induced HL-60 cells. Using these parameters, model analysis predicted that MAPK activation was bistable as a function of ATRA exposure. Conformational experiments supported ATRA-induced bistability. Additionally, the model captured intermediate and phenotypic gene expression data. Knockout analysis suggested Gfi-1 and PPARg were critical to the ATRAinduced differentiation program. These findings, combined with other literature evidence, suggested that reinforcing feedback is central to hyperactive signaling in a diversity of cell fate programs.

  7. Development of Calculation Module for Intake Retention Functions based on Occupational Intakes of Radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Siwan; Kwon, Tae-Eun; Lee, Jai-Ki [Hanyang Univ., Seoul (Korea, Republic of); Lee, Jong-Il; Kim, Jang-Lyul [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    In internal dosimetry, intake retention and excretion functions are essential to estimate intake activity using bioassay sample such as whole body counter, lung counter, and urine sample. Even though ICRP (International Commission on Radiological Protection)provides the functions in some ICRP publications, it is needed to calculate the functions because the functions from the publications are provided for very limited time. Thus, some computer program are generally used to calculate intake retention and excretion functions and estimate intake activity. OIR (Occupational Intakes of Radionuclides) will be published soon by ICRP, which totally replaces existing internal dosimetry models and relevant data including intake retention and excretion functions. Thus, the calculation tool for the functions is needed based on OIR. In this study, we developed calculation module for intake retention and excretion functions based on OIR using C++ programming language with Intel Math Kernel Library. In this study, we developed the intake retention and excretion function calculation module based on OIR using C++ programing language.

  8. Development of Calculation Module for Intake Retention Functions based on Occupational Intakes of Radionuclides

    International Nuclear Information System (INIS)

    Noh, Siwan; Kwon, Tae-Eun; Lee, Jai-Ki; Lee, Jong-Il; Kim, Jang-Lyul

    2014-01-01

    In internal dosimetry, intake retention and excretion functions are essential to estimate intake activity using bioassay sample such as whole body counter, lung counter, and urine sample. Even though ICRP (International Commission on Radiological Protection)provides the functions in some ICRP publications, it is needed to calculate the functions because the functions from the publications are provided for very limited time. Thus, some computer program are generally used to calculate intake retention and excretion functions and estimate intake activity. OIR (Occupational Intakes of Radionuclides) will be published soon by ICRP, which totally replaces existing internal dosimetry models and relevant data including intake retention and excretion functions. Thus, the calculation tool for the functions is needed based on OIR. In this study, we developed calculation module for intake retention and excretion functions based on OIR using C++ programming language with Intel Math Kernel Library. In this study, we developed the intake retention and excretion function calculation module based on OIR using C++ programing language

  9. The Hill Chart Calculation for Pelton Runner Models using the HydroHillChart - Pelton Module Software

    Directory of Open Access Journals (Sweden)

    Adelina Bostan

    2015-07-01

    Full Text Available The Pelton turbines industrial design is based on the hill chart characteristics obtained by measuring the models. Primary data measurements used to obtain the hill chart can be processed graphically, by hand or by using graphic programs respectively CAD programs; the HydroHillChart - Pelton module software is a specialized tool in achieving the hill chart, using interpolation cubic spline functions. Thereby, based on measurements of several models of Pelton turbines, a computerized library, used to design industrial Pelton turbines can be created. The paper presents the universal characteristics calculated by using the HydroHillChart - Pelton module software for a series of Pelton runners.

  10. Training of Teachers and Teaching Services Specialists for the Design and Implementation of the "School Psychology Master Program

    Directory of Open Access Journals (Sweden)

    Maksimova L.A.

    2015-11-01

    Full Text Available The article presents the experience of organizing the training courses for teachers and teaching services specialists for design and implementation of the basic professional educational pedagogical master program in a psycho-pedagogical training direction (educational psychologist with enhanced internship for students in a context of networking. The authors submit a modular design of training program. The first module includes methodological bases of the design and implementation of the basic professional educational master program. The second module includes legal coverage of the design and implementation of the basic professional educational master program. The third module consists of design and implementation of the basic professional educational master program in a psycho-pedagogical training direction (educational psychologist. The program involves a variety of active and interactive educational technology, providing the development of professional activities: remote technology, expert seminars, design stations, panels and plenary discussions, business games, round-table discussions.

  11. Training in remote monitoring technology. Digital camera module-14(DCM-14)

    International Nuclear Information System (INIS)

    Caskey, Susan

    2006-01-01

    The DCM-14 (Digital Camera Module) is the backbone of current IAEA remote monitoring surveillance systems. The control module is programmable with features for encryption, authentication, image compression and scene change detection. It can take periodic or triggered images under a variety of time sequences. This training session covered the DCM-14 features and related programming in DCMSET. It also described the processes for receiving, archiving and backing up the camera images using DCMPOLL and GEMINI software. Setting up a DCM-14 camera controller in the configuration of the remote monitoring system at Joyo formed an exercise. (author)

  12. Development of module-based simulation system for nuclear power plant

    International Nuclear Information System (INIS)

    Yoshikawa, H.

    1990-01-01

    Module-based Simulation System (MSS) has been developed to realize a new software environment enabling versatile dynamic simulation of a complex nuclear power plant system flexibly. Described in the paper are (i) fundamental methods utilized in MMS and its software systemization, (ii) development of human interface system to help users in generating integrated simulation programs automatically, and (iii) development of an intelligent user support system for helping users in the two phases of automatical semantic diagnosis and consultation to automatic input data setup for the MSS-generated programs

  13. A Self-Instructional Course in Student Financial Aid Administration. Module 3: The Legislative and Regulatory Processes. Second Edition.

    Science.gov (United States)

    Washington Consulting Group, Inc., Washington, DC.

    The third of a 17-module self-instructional course on student financial aid administration, this module offers a systematic introduction to the management of federal financial aid programs authorized by Title IV of the Higher Education Act to novice financial aid administrators and other institutional personnel. It teaches the administrator to…

  14. Computer programming in the UK undergraduate mathematics curriculum

    Science.gov (United States)

    Sangwin, Christopher J.; O'Toole, Claire

    2017-11-01

    This paper reports a study which investigated the extent to which undergraduate mathematics students in the United Kingdom are currently taught to programme a computer as a core part of their mathematics degree programme. We undertook an online survey, with significant follow-up correspondence, to gather data on current curricula and received replies from 46 (63%) of the departments who teach a BSc mathematics degree. We found that 78% of BSc degree courses in mathematics included computer programming in a compulsory module but 11% of mathematics degree programmes do not teach programming to all their undergraduate mathematics students. In 2016, programming is most commonly taught to undergraduate mathematics students through imperative languages, notably MATLAB, using numerical analysis as the underlying (or parallel) mathematical subject matter. Statistics is a very popular choice in optional courses, using the package R. Computer algebra systems appear to be significantly less popular for compulsory first-year courses than a decade ago, and there was no mention of logic programming, functional programming or automatic theorem proving software. The modal form of assessment of computing modules is entirely by coursework (i.e. no examination).

  15. Language constructs for modular parallel programs

    Energy Technology Data Exchange (ETDEWEB)

    Foster, I.

    1996-03-01

    We describe programming language constructs that facilitate the application of modular design techniques in parallel programming. These constructs allow us to isolate resource management and processor scheduling decisions from the specification of individual modules, which can themselves encapsulate design decisions concerned with concurrence, communication, process mapping, and data distribution. This approach permits development of libraries of reusable parallel program components and the reuse of these components in different contexts. In particular, alternative mapping strategies can be explored without modifying other aspects of program logic. We describe how these constructs are incorporated in two practical parallel programming languages, PCN and Fortran M. Compilers have been developed for both languages, allowing experimentation in substantial applications.

  16. City and County Solar PV Training Program, Module 1: Goal Setting and Clarification

    Energy Technology Data Exchange (ETDEWEB)

    McLaren, Joyce A. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2018-02-12

    This module will help attendees understand nuances between different types of renewable energy goals, the importance of terminology when setting and announcing goals, the value of formally clarifying priorities, and how priorities may impact procurement options. It is the first training in a series intended to help municipal staff procure solar PV for their land and buildings.

  17. Abort Region Determinator (ARD) module feasibility report. Mission planning, mission analysis and software formulation

    Science.gov (United States)

    Draeger, B. G.; Joyner, J. A.

    1976-01-01

    A detailed performance evaluation of the Abort Region Determinator (ARD) module design was provided in support of OFT-1 ascent and OFT-1 intact launch aborts. The evaluation method used compared ARD results against results obtained using the full-up Space Vehicle Dynamic Simulations program under the same conditions. Results were presented for each of the three major ARD math models: (1) the ascent numerical integrator; (2) the mass model, and (3) the second stage predictor as well as the total ARD module. These results demonstrate that the baselined ARD module meets all design objectives for mission control center orbital flight test launch/abort support.

  18. Visualization program development using Java

    International Nuclear Information System (INIS)

    Sasaki, Akira; Suto, Keiko

    2002-03-01

    Method of visualization programs using Java for the PC with the graphical user interface (GUI) is discussed, and applied to the visualization and analysis of 1D and 2D data from experiments and numerical simulations. Based on an investigation of programming techniques such as drawing graphics and event driven program, example codes are provided in which GUI is implemented using the Abstract Window Toolkit (AWT). The marked advantage of Java comes from the inclusion of library routines for graphics and networking as its language specification, which enables ordinary scientific programmers to make interactive visualization a part of their simulation codes. Moreover, the Java programs are machine independent at the source level. Object oriented programming (OOP) methods used in Java programming will be useful for developing large scientific codes which includes number of modules with better maintenance ability. (author)

  19. Injection Molding Parameters Calculations by Using Visual Basic (VB) Programming

    Science.gov (United States)

    Tony, B. Jain A. R.; Karthikeyen, S.; Alex, B. Jeslin A. R.; Hasan, Z. Jahid Ali

    2018-03-01

    Now a day’s manufacturing industry plays a vital role in production sectors. To fabricate a component lot of design calculation has to be done. There is a chance of human errors occurs during design calculations. The aim of this project is to create a special module using visual basic (VB) programming to calculate injection molding parameters to avoid human errors. To create an injection mold for a spur gear component the following parameters have to be calculated such as Cooling Capacity, Cooling Channel Diameter, and Cooling Channel Length, Runner Length and Runner Diameter, Gate Diameter and Gate Pressure. To calculate the above injection molding parameters a separate module has been created using Visual Basic (VB) Programming to reduce the human errors. The outcome of the module dimensions is the injection molding components such as mold cavity and core design, ejector plate design.

  20. Closed Environment Module - modularization and extension of the V-HAB

    Science.gov (United States)

    Plötner, Peter; Czupalla, M. Markus; Zhukov, Anton

    2012-07-01

    The `Virtual Habitat' (V-HAB), is a Life Support System (LSS) simulation, created to provide the possibility for dynamic simulation of LSS for future human spaceflight missions. V-HAB creates the option to optimize LSS during early design phases. Furthermore, it allows simulating e.g. worst case scenarios which cannot be tested in reality. In a nutshell the tool allows the testing of LSS robustness by means of computer simulations. V-HAB is a modular simulation consisting of a: Closed Environment Module (CEM) Crew Module Biological Module Physio-Chemical Module The focus of the paper will be the Closed Environment Module (CEM) which is the core of V-HAB. The main function of the CEM is the embedding of all modules in the entire simulation and the control of the LSS. The CEM includes the possibility to simulate an arbitrary number of compartments and tanks with the interaction between connected compartments. Furthermore, a control program to actuate the LSS Technologies was implemented in the CEM, and is also introduced. In this paper the capabilities of the CEM are introduced based on selected test cases. In particular the following capabilities are demonstrated: Supply Leakage ON/OFF controller Power management Un-/docking Controller for tanks with maximum filling degree The CEM of the V-HAB simulation was verified by simulating the Atmosphere Revitalization part of the ISS and comparing it to actual measurement data. The results of this analysis are also presented in the paper.

  1. Development of thermal-hydraulic analysis methodology for multiple modules of water-cooled breeder blanket in fusion DEMO reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Geon-Woo; Lee, Jeong-Hun [Department of Nuclear Engineering, Seoul National University 1 Gwanak-ro, Gwanak-gu, Seoul 151-744 (Korea, Republic of); Cho, Hyoung-Kyu, E-mail: chohk@snu.ac.kr [Department of Nuclear Engineering, Seoul National University 1 Gwanak-ro, Gwanak-gu, Seoul 151-744 (Korea, Republic of); Park, Goon-Cherl [Department of Nuclear Engineering, Seoul National University 1 Gwanak-ro, Gwanak-gu, Seoul 151-744 (Korea, Republic of); Im, Kihak [National Fusion Research Institute, 169-148, Yuseong-gu, Daejeon 305-806 (Korea, Republic of)

    2016-02-15

    Highlights: • A methodology to simulate the K-DEMO blanket system was proposed. • The results were compared with the CFD, to verify the prediction capability of MARS. • 46 Blankets in a single sector in K-DEMO were simulated using MARS-KS. • Supervisor program was devised to handle each blanket module individually. • The calculation results showed the flow rates, pressure drops, and temperatures. - Abstract: According to the conceptual design of the fusion DEMO reactor proposed by the National Fusion Research Institute of Korea, the water-cooled breeding blanket system incorporates a total of 736 blanket modules. The heat flux and neutron wall loading to each blanket module vary along their poloidal direction, and hence, thermal analysis for at least one blanket sector is required to confirm that the temperature limitations of the materials are satisfied in all the blanket modules. The present paper proposes a methodology of thermal analysis for multiple modules of the blanket system using a nuclear reactor thermal-hydraulic analysis code, MARS-KS. In order to overcome the limitations of the code, caused by the restriction on the number of computational nodes, a supervisor program was devised, which handles each blanket module separately at first, and then corrects the flow rate, considering pressure drops that occur in each module. For a feasibility test of the proposed methodology, 46 blankets in a single sector were simulated; the calculation results of the parameters, such as mass flow, pressure drops, and temperature distribution in the multiple blanket modules showed that the multi-module analysis method can be used for efficient thermal-hydraulic analysis of the fusion DEMO reactor.

  2. Imposed Thermal Fatigue and Post-Thermal-Cycle Wear Resistance of Biomimetic Gray Cast Iron by Laser Treatment

    Science.gov (United States)

    Sui, Qi; Zhou, Hong; Zhang, Deping; Chen, Zhikai; Zhang, Peng

    2017-08-01

    The present study aims to create coupling biomimetic units on gray cast iron substrate by laser surface treatment (LST). LSTs for single-step (LST1) and two-step (LST2) processes, were carried out on gray cast iron in different media (air and water). Their effects on microstructure, thermal fatigue, and post-thermal-cycle wear (PTW) resistance on the specimens were studied. The tests were carried out to examine the influence of crack-resistance behavior as well as the biomimetic surface on its post-thermal-cycle wear behavior and different units, with different laser treatments for comparison. Results showed that LST2 enhanced the PTW behaviors of gray cast iron, which then led to an increase in its crack resistance. Among the treated cast irons, the one treated by LST2 in air showed the lowest residual stress, due to the positive effect of the lower steepness of the thermal gradient. Moreover, the same specimen showed the best PTW performance, due to its superior crack resistance and higher hardness as a result of it.

  3. User's manual for the National Water-Quality Assessment Program Invertebrate Data Analysis System (IDAS) software, version 5

    Science.gov (United States)

    Cuffney, Thomas F.; Brightbill, Robin A.

    2011-01-01

    The Invertebrate Data Analysis System (IDAS) software was developed to provide an accurate, consistent, and efficient mechanism for analyzing invertebrate data collected as part of the U.S. Geological Survey National Water-Quality Assessment (NAWQA) Program. The IDAS software is a stand-alone program for personal computers that run Microsoft Windows(Registered). It allows users to read data downloaded from the NAWQA Program Biological Transactional Database (Bio-TDB) or to import data from other sources either as Microsoft Excel(Registered) or Microsoft Access(Registered) files. The program consists of five modules: Edit Data, Data Preparation, Calculate Community Metrics, Calculate Diversities and Similarities, and Data Export. The Edit Data module allows the user to subset data on the basis of taxonomy or sample type, extract a random subsample of data, combine or delete data, summarize distributions, resolve ambiguous taxa (see glossary) and conditional/provisional taxa, import non-NAWQA data, and maintain and create files of invertebrate attributes that are used in the calculation of invertebrate metrics. The Data Preparation module allows the user to select the type(s) of sample(s) to process, calculate densities, delete taxa on the basis of laboratory processing notes, delete pupae or terrestrial adults, combine lifestages or keep them separate, select a lowest taxonomic level for analysis, delete rare taxa on the basis of the number of sites where a taxon occurs and (or) the abundance of a taxon in a sample, and resolve taxonomic ambiguities by one of four methods. The Calculate Community Metrics module allows the user to calculate 184 community metrics, including metrics based on organism tolerances, functional feeding groups, and behavior. The Calculate Diversities and Similarities module allows the user to calculate nine diversity and eight similarity indices. The Data Export module allows the user to export data to other software packages (CANOCO, Primer

  4. Modules program structures and the structuring of operating systems

    NARCIS (Netherlands)

    Bron, C.; Duijvestijn, W.; Lockemann, P.C.

    1981-01-01

    In this paper some views are presented on the way in which complex systems, such as Operating Systems and the programs to be interfaced with them can be constructed, and how such systems may become heavily library oriented. Although such systems have a dynamic nature, all interfacing within and

  5. Modules to enhance smart lighting education

    Science.gov (United States)

    Bunch, Robert M.; Joenathan, Charles; Connor, Kenneth; Chouikha, Mohamed

    2012-10-01

    Over the past several years there has been a rapid advancement in solid state lighting applications brought on by the development of high efficiency light emitting diodes. Development of lighting devices, systems and products that meet the demands of the future lighting marketplace requires workers from many disciplines including engineers, scientists, designers and architects. The National Science Foundation has recognized this fact and established the Smart Lighting Engineering Research Center that promotes research leading to smart lighting systems, partners with industry to enhance innovation and educates a diverse, world-class workforce. The lead institution is Rensselaer Polytechnic Institute with core partners Boston University and The University of New Mexico. Outreach partners include Howard University, Morgan State University, and Rose-Hulman Institute of Technology. Because of the multidisciplinary nature of advanced smart lighting systems workers often have little or no formal education in basic optics, lighting and illumination. This paper describes the initial stages of the development of self-contained and universally applicable educational modules that target essential optics topics needed for lighting applications. The modules are intended to be easily incorporated into new and existing courses by a variety of educators and/or to be used in a series of stand-alone, asynchronous training exercises by new graduate students. The ultimate goal of this effort is to produce resources such as video lectures, video presentations of students-teaching-students, classroom activities, assessment tools, student research projects and laboratories integrated into learning modules. Sample modules and resources will be highlighted. Other outreach activities such as plans for coursework, undergraduate research, design projects, and high school enrichment programs will be discussed.

  6. REMTWO - WRS system module number 299 for calculating the removal flux in a slab shield

    International Nuclear Information System (INIS)

    Grimstone, M.J.

    1978-06-01

    The WRS Modular Programming System has been developed as a means by which programmes may be more efficiently constructed, maintained and modified. In this system a module is a self-contained unit typically composed of one or more Fortran routines, and a programme is constructed from a number of such modules. This report describes one WRS module, the function of which is to calculate the uncollided flux due to a distributed source in a one-dimensional plane geometry system. A method is used in which the flux is approximated by the sum of diffusion equation solutions. The information given in this manual is of use both to the programmer wishing to incorporate the module in a programme, and to the user of such a programme. (author)

  7. Mining Functional Modules in Heterogeneous Biological Networks Using Multiplex PageRank Approach.

    Science.gov (United States)

    Li, Jun; Zhao, Patrick X

    2016-01-01

    Identification of functional modules/sub-networks in large-scale biological networks is one of the important research challenges in current bioinformatics and systems biology. Approaches have been developed to identify functional modules in single-class biological networks; however, methods for systematically and interactively mining multiple classes of heterogeneous biological networks are lacking. In this paper, we present a novel algorithm (called mPageRank) that utilizes the Multiplex PageRank approach to mine functional modules from two classes of biological networks. We demonstrate the capabilities of our approach by successfully mining functional biological modules through integrating expression-based gene-gene association networks and protein-protein interaction networks. We first compared the performance of our method with that of other methods using simulated data. We then applied our method to identify the cell division cycle related functional module and plant signaling defense-related functional module in the model plant Arabidopsis thaliana. Our results demonstrated that the mPageRank method is effective for mining sub-networks in both expression-based gene-gene association networks and protein-protein interaction networks, and has the potential to be adapted for the discovery of functional modules/sub-networks in other heterogeneous biological networks. The mPageRank executable program, source code, the datasets and results of the presented two case studies are publicly and freely available at http://plantgrn.noble.org/MPageRank/.

  8. Auditory sensitivity to spectral modulation phase reversal as a function of modulation depth.

    Science.gov (United States)

    Buss, Emily; Grose, John

    2018-01-01

    The present study evaluated auditory sensitivity to spectral modulation by determining the modulation depth required to detect modulation phase reversal. This approach may be preferable to spectral modulation detection with a spectrally flat standard, since listeners appear unable to perform the task based on the detection of temporal modulation. While phase reversal thresholds are often evaluated by holding modulation depth constant and adjusting modulation rate, holding rate constant and adjusting modulation depth supports rate-specific assessment of modulation processing. Stimuli were pink noise samples, filtered into seven octave-wide bands (0.125-8 kHz) and spectrally modulated in dB. Experiment 1 measured performance as a function of modulation depth to determine appropriate units for adaptive threshold estimation. Experiment 2 compared thresholds in dB for modulation detection with a flat standard and modulation phase reversal; results supported the idea that temporal cues were available at high rates for the former but not the latter. Experiment 3 evaluated spectral modulation phase reversal thresholds for modulation that was restricted to either one or two neighboring bands. Flanking bands of unmodulated noise had a larger detrimental effect on one-band than two-band targets. Thresholds for high-rate modulation improved with increasing carrier frequency up to 2 kHz, whereas low-rate modulation appeared more consistent across frequency, particularly in the two-band condition. Experiment 4 measured spectral weights for spectral modulation phase reversal detection and found higher weights for bands in the spectral center of the stimulus than for the lowest (0.125 kHz) or highest (8 kHz) band. Experiment 5 compared performance for highly practiced and relatively naïve listeners, and found weak evidence of a larger practice effect at high than low spectral modulation rates. These results provide preliminary data for a task that may provide a better estimate of

  9. Photovoltaic module with integrated power conversion and interconnection system - the European project PV-MIPS

    OpenAIRE

    Henze, N.; Engler, A.; Zacharias, P.

    2006-01-01

    Within the 6th framework program funded by the European Commission the project PV-MIPS (Photovoltaic Module with Integrated Power Conversion System) was launched in November 2004. Together with eleven European partners from Germany, Austria, Greece and the Netherlands a solar module with integrated in-verter shall be developed that can feed solar electricity directly into the grid. The challenging objective of the project is to reduce the total costs of a PV system. At the same time lifetime ...

  10. Molecular Mechanisms Modulating the Phenotype of Macrophages and Microglia

    Directory of Open Access Journals (Sweden)

    Stephanie A. Amici

    2017-11-01

    Full Text Available Macrophages and microglia play crucial roles during central nervous system development, homeostasis and acute events such as infection or injury. The diverse functions of tissue macrophages and microglia are mirrored by equally diverse phenotypes. A model of inflammatory/M1 versus a resolution phase/M2 macrophages has been widely used. However, the complexity of macrophage function can only be achieved by the existence of varied, plastic and tridimensional macrophage phenotypes. Understanding how tissue macrophages integrate environmental signals via molecular programs to define pathogen/injury inflammatory responses provides an opportunity to better understand the multilayered nature of macrophages, as well as target and modulate cellular programs to control excessive inflammation. This is particularly important in MS and other neuroinflammatory diseases, where chronic inflammatory macrophage and microglial responses may contribute to pathology. Here, we perform a comprehensive review of our current understanding of how molecular pathways modulate tissue macrophage phenotype, covering both classic pathways and the emerging role of microRNAs, receptor-tyrosine kinases and metabolism in macrophage phenotype. In addition, we discuss pathway parallels in microglia, novel markers helpful in the identification of peripheral macrophages versus microglia and markers linked to their phenotype.

  11. Development of the module inspection system for new standardized radiation monitoring modules

    International Nuclear Information System (INIS)

    Furukawa, Masami; Shimizu, Kazuaki; Hiruta, Toshihito; Mizugaki, Toshio; Ohi, Yoshihiro; Chida, Tooru.

    1994-10-01

    This report mentions about the module inspection system which does the maintenance check of the monitoring modules adapted the new monitoring standard, as well as the result of the verification of the modules. The module inspection system is the automatic measurement system with the computer. The system can perform the functional and the characteristic examination of the monitoring modules, the calibration with radiation source and inspection report. In the verification of the monitoring module, three major items were tested, the adaptability for the new monitoring standard, the module functions and each characteristics. All items met the new monitoring standard. (author)

  12. Reduced multiplication modules

    Indian Academy of Sciences (India)

    if M is a von Neumann regular module (VNM); i.e., every principal submodule of M is a summand submodule. Also if M is an injective R-module, then M is a VNM. Keywords. Multiplication module; reduced module; minimal prime submodule;. Zariski topology; extremally disconnected. 1. Introduction. In this paper all rings are ...

  13. A Buildings Module for the Stochastic Energy Deployment System

    Energy Technology Data Exchange (ETDEWEB)

    Lacommare, Kristina S H; Marnay, Chris; Stadler, Michael; Borgeson, Sam; Coffey, Brian; Komiyama, Ryoichi; Lai, Judy

    2008-05-15

    The U.S. Department of Energy (USDOE) is building a new long-range (to 2050) forecasting model for use in budgetary and management applications called the Stochastic Energy Deployment System (SEDS), which explicitly incorporates uncertainty through its development within the Analytica(R) platform of Lumina Decision Systems. SEDS is designed to be a fast running (a few minutes), user-friendly model that analysts can readily run and modify in its entirety through a visual programming interface. Lawrence Berkeley National Laboratory is responsible for implementing the SEDS Buildings Module. The initial Lite version of the module is complete and integrated with a shared code library for modeling demand-side technology choice developed by the National Renewable Energy Laboratory (NREL) and Lumina. The module covers both commercial and residential buildings at the U.S. national level using an econometric forecast of floorspace requirement and a model of building stock turnover as the basis for forecasting overall demand for building services. Although the module is fundamentally an engineering-economic model with technology adoption decisions based on cost and energy performance characteristics of competing technologies, it differs from standard energy forecasting models by including considerations of passive building systems, interactions between technologies (such as internal heat gains), and on-site power generation.

  14. Method for calibration-free scanned-wavelength modulation spectroscopy for gas sensing

    Science.gov (United States)

    Hanson, Ronald K.; Jeffries, Jay B.; Sun, Kai; Sur, Ritobrata; Chao, Xing

    2018-04-10

    A method of calibration-free scanned-wavelength modulation spectroscopy (WMS) absorption sensing is provided by obtaining absorption lineshape measurements of a gas sample on a sensor using 1f-normalized WMS-2f where an injection current to an injection current-tunable diode laser (TDL) is modulated at a frequency f, where a wavelength modulation and an intensity modulation of the TDL are simultaneously generated, extracting using a numerical lock-in program and a low-pass filter appropriate band-width WMS-nf (n=1, 2, . . . ) signals, where the WMS-nf signals are harmonics of the f, determining a physical property of the gas sample according to ratios of the WMS-nf signals, determining the zero-absorption background using scanned-wavelength WMS, and determining non-absorption losses using at least two of the harmonics, where a need for a non-absorption baseline measurement is removed from measurements in environments where collision broadening has blended transition linewidths, where calibration free WMS measurements without knowledge of the transition linewidth is enabled.

  15. C-MORE Professional Development Training Program for Graduate Students and Post-Docs

    Science.gov (United States)

    Bruno, B. C.; DeLeo, F.; Bottjer, D.; Jungbluth, S.; Burkhardt, B.; Hawco, N.; Boiteau, R.

    2012-12-01

    The Center for Microbial Oceanography: Research and Education (C-MORE) is a National Science Foundation-sponsored Science and Technology Center. C-MORE comprises six partner institutions: University of Hawaii (headquarters), Massachusetts Institute of Technology, Woods Hole Oceanographic Institution, Oregon State University, University of California at Santa Cruz and Monterey Bay Aquarium Research Institute. C-MORE's Professional Development Training Program is aimed at equipping graduate students and post-docs at all six institutions with the skills and experiences needed to maximize their potential and succeed in their professional careers. This program is administered through the C-MORE Education Office and was developed in close collaboration with graduate students, post-docs, and faculty. This program has formal but flexible requirements. There is only one required module (Outreach). The seven optional modules include: Science Communication, Leadership, Mentoring, Teaching, Research Exchange, Diversity and Proposal Writing. Masters students choose three optional modules; Ph.D. students and post-docs choose five. Most modules consist of a training component, followed by a practical component. All participants will are expected to complete program evaluations. Below are some examples of program offerings: Science Communication Module In partnership with the Communication Partnership for Science and the Sea, C-MORE organized three Science Communication workshops at the University of Hawaii, Monterey Bay Aquarium Research Institute and Massachusetts Institute of Technology. These workshops train participants to distill their research into language that is free of jargon and accessible to a general audience. After the training, participants are asked to produce a communication product based on their research, such as a magazine article, press release, podcast or a blog. Diversity Module To date, C-MORE has organized three teleconferences on diversity, attended by

  16. NASA's Constellation Program: Milestones Towards the Frontier

    Science.gov (United States)

    Hanley, Jeffrey M.; Thomas, Lawrence D.; Rhatigan, Jennifer L.; Boatright, Tony J.

    2009-01-01

    This slide presentation reviews the status and progress made in the Constellation Program's work towards the goal of lunar and Martian exploration flights. It includes views of the various components of the program, and reviews the status of the engine tests, and the development of the Ares I-X towards test launch, the Orion Crew Module, the launch abort system, and the ground operations facilities.

  17. Evaluation of the Virtual Physiology of Exercise Laboratory Program

    Science.gov (United States)

    Dobson, John L.

    2009-01-01

    The Virtual Physiology of Exercise Laboratory (VPEL) program was created to simulate the test design, data collection, and analysis phases of selected exercise physiology laboratories. The VPEL program consists of four modules: (1) cardiovascular, (2) maximal O[subscript 2] consumption [Vo[subscript 2max], (3) lactate and ventilatory thresholds,…

  18. Divisible ℤ-modules

    Directory of Open Access Journals (Sweden)

    Futa Yuichi

    2016-03-01

    Full Text Available In this article, we formalize the definition of divisible ℤ-module and its properties in the Mizar system [3]. We formally prove that any non-trivial divisible ℤ-modules are not finitely-generated.We introduce a divisible ℤ-module, equivalent to a vector space of a torsion-free ℤ-module with a coefficient ring ℚ. ℤ-modules are important for lattice problems, LLL (Lenstra, Lenstra and Lovász base reduction algorithm [15], cryptographic systems with lattices [16] and coding theory [8].

  19. Amplitude modulation detection with concurrent frequency modulation.

    Science.gov (United States)

    Nagaraj, Naveen K

    2016-09-01

    Human speech consists of concomitant temporal modulations in amplitude and frequency that are crucial for speech perception. In this study, amplitude modulation (AM) detection thresholds were measured for 550 and 5000 Hz carriers with and without concurrent frequency modulation (FM), at AM rates crucial for speech perception. Results indicate that adding 40 Hz FM interferes with AM detection, more so for 5000 Hz carrier and for frequency deviations exceeding the critical bandwidth of the carrier frequency. These findings suggest that future cochlear implant processors, encoding speech fine-structures may consider limiting the FM to narrow bandwidth and to low frequencies.

  20. EPICS IOC module development and implementation for the ISTTOK machine subsystem operation and control

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Paulo, E-mail: pricardofc@ipfn.ist.utl.pt [Associacao EURATOM/IST, Instituto de Plasmas e Fusao Nuclear-Laboratorio Associado, Instituto Superior Tecnico, P-1049-001 Lisboa (Portugal); Duarte, Andre; Pereira, Tiago; Carvalho, Bernardo; Sousa, Jorge; Fernandes, Horacio [Associacao EURATOM/IST, Instituto de Plasmas e Fusao Nuclear-Laboratorio Associado, Instituto Superior Tecnico, P-1049-001 Lisboa (Portugal); Correia, Carlos [Grupo de Electronica e Instrumentacao-Centro de Instrumentacao, Departamento de Fisica, Universidade de Coimbra, P-3004-516 Coimbra (Portugal); Goncalves, Bruno; Varandas, Carlos [Associacao EURATOM/IST, Instituto de Plasmas e Fusao Nuclear-Laboratorio Associado, Instituto Superior Tecnico, P-1049-001 Lisboa (Portugal)

    2011-10-15

    This paper presents a developed, tested and integrated EPICS IOC (I/O controller) module solution for the ISTTOK tokamak machine operation and control for the vacuum and gas injection systems. The work is organized in two software layers which communicate through a serial RS-232 communication protocol. The first software layer is an EPICS IOC module running as a computer server application capable of receiving requests from remote or local clients providing driver interface to the system by forwarding requested commands and receiving system and control operation status. The second software layer is the firmware running in Microchip dsPIC microcontroller modules which performs the interface from RS-232 optical fiber serial protocol to EPICS IOC module. The dsPIC module communicates to the ISTTOK tokamak sensors and actuators via RS-485 and is programmed with a new protocol developed for this purpose that allows EPICS IOC module command sending/receiving, machine operation control and monitoring and system status information. Communication between EPICS IOC module and clients is achieved via a TCP/IP and UDP protocol referred as Channel Access. In addition, the EPICS IOC module provides user client applications access allowing operators to perform remote or local monitoring, operation and control.

  1. PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid P

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This document describe the software programs for the Programmable Logic Controller and the Datable Access Module for Pumping Instrumentation and Control skid ''P''. The Appendices contains copies of the printouts of these software programs

  2. PLC/DTAM Software Programs for Pumping Instrumentation and Control Skid L

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    2000-01-03

    This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''L''. The Appendices contains copies of the printouts of these software programs.

  3. Whole Module Offgas Test Report: Space-Xl Dragon Module

    Science.gov (United States)

    James, John T.

    2012-01-01

    On September 26 and September 28,2012 a chemist from the JSC Toxicology Group acquired samples of air in 500 m1 evacuated canisters from the sealed Space-Xl Dragon Module. One sample was also acquired from Space-X Facility near the module at the start of the test. Samples of the module air were taken in triplicate once the module had been sealed, and then taken again in triplicate 1.98 days later. Ofthe triplicate samples, the first served as a line purge, and the last two were analyzed. The results of 5 samples are reported.

  4. Investigation of thermal and temporal responses of ionization chambers in radiation dosimetry.

    Science.gov (United States)

    AlMasri, Hussein; Funyu, Akira; Kakinohana, Yasumasa; Murayama, Sadayuki

    2012-07-01

    The ionization chamber is a primary dosimeter that is used in radiation dosimetry. Generally, the ion chamber response requires temperature/pressure correction according to the ideal gas law. However, this correction does not consider the thermal volume effect of chambers. The temporal and thermal volume effects of various chambers (CC01, CC13, NACP parallel-plate, PTW) with different wall and electrode materials have been studied in a water phantom. Measurements were done after heating the water with a suitable heating system, and chambers were submerged for a sufficient time to allow for temperature equilibrium. Temporal results show that all chambers equilibrate quickly in water. The equilibration time was between 3 and 5 min for all chambers. Thermal results show that all chambers expanded in response to heating except for the PTW, which contracted. This might be explained by the differences in the volumes of all chambers and also by the difference in wall material composition of PTW from the other chambers. It was found that the smallest chamber, CC01, showed the greatest expansion. The magnitude of the expansion was ~1, 0.8, and 0.9% for CC01, CC13, and parallel-plate chambers, respectively, in the temperature range of 295-320 K. The magnitude of the detected contraction was <0.3% for PTW in the same temperature range. For absolute dosimetry, it is necessary to make corrections for the ion chamber response, especially for small ion chambers like the CC01. Otherwise, room and water phantom temperatures should remain within a close range.

  5. Evaluation of w values for carbon beams in air, using a graphite calorimeter.

    Science.gov (United States)

    Sakama, Makoto; Kanai, Tatsuaki; Fukumura, Akifumi; Abe, Kyoko

    2009-03-07

    Despite recent progress in carbon therapy, accurate values for physical data such as the w value in air or stopping power ratios for ionization chamber dosimetry have not been obtained. The absorbed dose to graphite obtained with the graphite calorimeter was compared with that obtained using the ionization chambers following the IAEA protocol in order to evaluate the w values in air for mono-energetic carbon beams of 135, 290, 400 and 430 MeV/n. Two cylindrical chambers (PTW type 30001 and PTW type 30011, Farmer) and two plane-parallel chambers (PTW type 23343, Markus and PTW type 34001, Roos) calibrated by the absorbed dose to graphite and exposure to the (60)Co photon beam were used. The comparisons to our calorimeter measurements revealed that, using the ionization chambers, the absorbed dose to graphite comes out low by 2-6% in this experimental energy range and with these chamber types and calibration methods. In the therapeutic energy range, the w values in air for carbon beams indicated a slight energy dependence; we, however, assumed these values to be constant for practical use because of the large uncertainty and unknown perturbation factors of the ionization chambers. The w values in air of the carbon beams were evaluated to be 35.72 J C(-1) +/- 1.5% in the energy range used in this study. This value is 3.5% larger than that recommended by the IAEA TRS 398 for heavy-ion beams. Using this evaluated result, the absorbed dose to water in the carbon beams would be increased by the same amount.

  6. Applied Physics Modules: Notes, Instructions, Data Sheets, Tests, and Test Answer Keys.

    Science.gov (United States)

    Southeast Community Coll., Lincoln, NE.

    These user instructions and related materials are designed to accompany a series of twenty-three applied physics modules which have been developed for postsecondary students in electrical, electronics, machine tool, metals, manufacturing, automotive, diesel, architecture, and civil drafting occupational programs. The instructions include an…

  7. A program for calculating group constants on the basis of libraries of evaluated neutron data

    International Nuclear Information System (INIS)

    Sinitsa, V.V.

    1987-01-01

    The GRUKON program is designed for processing libraries of evaluated neutron data into group and fine-group (having some 300 groups) microscopic constants. In structure it is a package of applications programs with three basic components: a monitor, a command language and a library of functional modules. The first operative version of the package was restricted to obtaining mid-group non-block cross-sections from evaluated neutron data libraries in the ENDF/B format. This was then used to process other libraries. In the next two versions, cross-section table conversion modules and self-shielding factor calculation modules, respectively, were added to the functions already in the package. Currently, a fourth version of the GRUKON applications program package, for calculation of sub-group parameters, is under preparation. (author)

  8. Developing an Implementation Plan. The Administration of Career Education: Module 8.

    Science.gov (United States)

    Drier, Harry N., Jr., Ed.; Martinez, Nancy S., Ed.

    The module is one of a series of eight developed to provide inservice education training for administrators of career education programs. An examination of basic scientific planning approaches and procedures is presented to provide the administrator with a basic tool to implement career education. Various scientific management techniques and their…

  9. Model Development of Degradation of PV Modules Backsheet with Locating Place of Module

    Energy Technology Data Exchange (ETDEWEB)

    Kempe, Michael D [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Wang, Yu [Case Western Reserve University; Fairbrother, Andrew [National Institute of Standards and Technology (NIST); Merzlic, Sebastien [Arkema; Julien, Scott [Northeastern University; Fridman, Lucas S. [Case Western Reserve University; Loyer, Camille [Arkema; Lefebvre, Amy L. [Arkema; O' Brien, Gregory [Arkema; Gu, Xiaohong [National Institute of Standards and Technology (NIST); Ji, Liang [Underwriters Laboratories; Boyce, Kenneth P. [Underwriters Laboratories; Wan, Kai-tak [Northeastern University; French, Roger H. [Case Western Reserve University; Bruckman, Laura S. [Case Western Reserve University

    2017-08-23

    Performance of a photovoltaic (PV) module is related to the micro-environment around the module. The position of photovoltaic modules in an array row have a large effect on the yellowing and gloss of PV module backsheet exposed in Dfa climatic zone (Gaithersburg, MD) with a polyethylene naphthalate (PEN) outer layer. Stress/Response models of yellowing and gloss-losing as function of location parameters of module, including the shed, row, measurement position in a same module and the distance of module location to the row center, are under development. The module installation height had the greatest influence on degradation of PEN PV backsheet in the Dfa climatic zone. The module backsheets at the end of an array have higher degradation rate (edge effect). The edge effect decreases with increasing of module installation heights.

  10. Modulation masking produced by second-order modulators

    DEFF Research Database (Denmark)

    Füllgrabe, Christian; Moore, Brian C.J.; Demany, Laurent

    2005-01-01

    Recent studies suggest that an auditory nonlinearity converts second-order sinusoidal amplitude modulation (SAM) (i.e., modulation of SAM depth) into a first-order SAM component, which contributes to the perception of second-order SAM. However, conversion may also occur in other ways such as coch...

  11. Electrochemically Modulated Gas/Liquid Separation Technology for In Situ Resource Utilization Process Streams, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In this phase I program MicroCell Technologies, LLC (MCT) proposes to demonstrate the feasibility of an electrochemically modulated phase separator for in situ...

  12. Extension of the COSYMA-ECONOMICS module - cost calculations based on different economic sectors

    International Nuclear Information System (INIS)

    Faude, D.

    1994-12-01

    The COSYMA program system for evaluating the off-site consequences of accidental releases of radioactive material to the atmosphere includes an ECONOMICS module for assessing economic consequences. The aim of this module is to convert various consequences (radiation-induced health effects and impacts resulting from countermeasures) caused by an accident into the common framework of economic costs; this allows different effects to be expressed in the same terms and thus to make these effects comparable. With respect to the countermeasure 'movement of people', the dominant cost categories are 'loss-of-income costs' and 'costs of lost capital services'. In the original version of the ECONOMICS module these costs are calculated on the basis of the total number of people moved. In order to take into account also regional or local economic peculiarities of a nuclear site, the ECONOMICS module has been extended: Calculation of the above mentioned cost categories is now based on the number of employees in different economic sectors in the affected area. This extension of the COSYMA ECONOMICS module is described in more detail. (orig.)

  13. Young module multiplicities and classifying the indecomposable Young permutation modules

    OpenAIRE

    Gill, Christopher C.

    2012-01-01

    We study the multiplicities of Young modules as direct summands of permutation modules on cosets of Young subgroups. Such multiplicities have become known as the p-Kostka numbers. We classify the indecomposable Young permutation modules, and, applying the Brauer construction for p-permutation modules, we give some new reductions for p-Kostka numbers. In particular we prove that p-Kostka numbers are preserved under multiplying partitions by p, and strengthen a known reduction given by Henke, c...

  14. Reaching consensus: a review on sexual health training modules for professional capacity building

    Directory of Open Access Journals (Sweden)

    Zahra Karimian

    2018-01-01

    Full Text Available Background: Professional capacity building (PCB is the focus point in health-related subjects.The present study was conducted to systematically review the existing sexual health training modules for health care providers.Methods: The following keywords were used to search: training, education, professional capacity, practitioner, sexual health, skill education, module, course, package and curriculum.The term MESH is referred to Medical Subject Headings and the following databases were investigated: MEDLINE, EMBASE, PubMed, Cumulative Index to Nursing and Allied Health Literature (CINAHL, The Cochrane Library and Web of Science, Scopus, Google Scholar, SID,Magiran, and Iranmedex. All articles from 1980 to 2015 were extracted. Online modules were excluded. Considering that lesson plan was the basis of instruction, the modules were selected based on the characteristics of the lesson plans.Results: A total number of 38 published training modules in the field of sexuality we redetermined. In total, more than half of the modules (58% were designed for medical doctor sand allied health professionals and the remaining (42% were for nurses and midwives. Almost all the modules (97% were introduced and utilized in developed countries, and only 3% were disseminated in developing countries.Conclusion: There are invaluable modules to build professional capacity in the field of sexual health. As a number of modules have been designed for nurses and midwifes, as the first-line health care providers, the use of these groups in sexual counseling and empowerment for sexual health is essential. No sexual health training program was designed in Iran. Therefore, designing such modules according to Iranian culture is strongly recommended.

  15. Reaching consensus: a review on sexual health training modules for professional capacity building.

    Science.gov (United States)

    Karimian, Zahra; Azin, Seied Ali; Javid, Nasrin; Araban, Marzieh; Maasoumi, Raziyeh; Aghayan, Shahrokh; Merghati Khoie, Effat

    2018-01-01

    Background: Professional capacity building (PCB) is the focus point in health-related subjects.The present study was conducted to systematically review the existing sexual health training modules for health care providers. Methods: The following keywords were used to search: training, education, professional capacity, practitioner, sexual health, skill education, module, course, package and curriculum.The term MESH is referred to Medical Subject Headings and the following databases were investigated: MEDLINE, EMBASE, PubMed, Cumulative Index to Nursing and Allied Health Literature (CINAHL), The Cochrane Library and Web of Science, Scopus, Google Scholar, SID,Magiran, and Iranmedex. All articles from 1980 to 2015 were extracted. Online modules were excluded. Considering that lesson plan was the basis of instruction, the modules were selected based on the characteristics of the lesson plans. Results: A total number of 38 published training modules in the field of sexuality we redetermined. In total, more than half of the modules (58%) were designed for medical doctor sand allied health professionals and the remaining (42%) were for nurses and midwives. Almost all the modules (97%) were introduced and utilized in developed countries, and only 3% were disseminated in developing countries. Conclusion: There are invaluable modules to build professional capacity in the field of sexual health. As a number of modules have been designed for nurses and midwifes, as the first-line health care providers, the use of these groups in sexual counseling and empowerment for sexual health is essential. No sexual health training program was designed in Iran. Therefore, designing such modules according to Iranian culture is strongly recommended.

  16. PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid ''M''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''M''. The Appendices contains copies of the printouts of these software programs

  17. Modulators for the S-band test linac at DESY

    Science.gov (United States)

    Bieler, M.; Choroba, S.; Hameister, J.; Lewin, H.-Ch.

    1995-07-01

    The development of adequate modulators for high peak power klystrons is one of the focus points for linear collider R&D programs. For the DESY/THD S-band linear collider study 150 MW rf-pulse power at 50 Hz repetition rate and 3 μs pulse duration is required [1]. Two different modulator schemes are under investigation. One is the conventional line type pulser, using a pulse forming network and a step up transformer, the other one is a hard tube pulser, using a dc power source at the full klystron voltage and a switch tube. This paper is focused on the modulator development for the S-band Test Linac at DESY. After a short overview over the test linac and a brief description of the 150 MW S-band klystron the circuitry of the line type pulse (LTP) is given. A hard tube pulser (HTP), which switches the high voltage directly from a storage capacitor to the klystron, has been built up at DESY. Circuitry and the results of the commissioning of the switch tube are reported.

  18. Evaluating the implementation and impacts of middle grades inquiry-based engineering design modules

    Science.gov (United States)

    Harlan, Jessica M.

    This dissertation uses a format where I present and discuss three articles that were written in conjunction with my work on a research and evaluation team. The articles are based on a multi-year project researching and evaluating the design, development, and implementation of a middle grades integrated Science, Technology, Engineering, and Mathematics (STEM) program. Each of the articles demonstrates the complexity in researching and evaluating curricular development in multifaceted, rapidly changing environments. While the focus of each article differs, they all examine research and evaluation in the context of the design and development of middle grades engineering-design modules. The selected articles address challenges associated with assessing program objectives and evaluating program quality in complex education programs.The first article, presented in Chapter 2, provides an overview of the nature of the EYE program and examines the extent to which participation in the EYE program resulted in the achievement of program objectives. There is evidence that EYE Module participation has a positive impact on participating students as well as teachers. This study also revealed challenges associated with determining the impact of program participation simultaneously with program revisions and assessment development. The second article, presented in Chapter 3, examined the evaluation of fidelity of implementation of inquiry-oriented educational programs. This article was intended to examine one way of triangulating information to determine fidelity while considering variation in implementation consistent with program theories of learning. When applying this model to implementation of the EYE program, we found many teachers were implementing the modules with low to moderate fidelity, especially math teachers. The third article, presented in Chapter 4, examined the factor structure of an occupational values scale intended to measure student interest in STEM careers

  19. A new VME timing module: TG8

    International Nuclear Information System (INIS)

    Beetham, C.G.; Daems, G.; Lewis, J.; Puccio, B.

    1992-01-01

    The two accelerator divisions of CERN, namely PS and SL, are defining a new common control system based on PC, VME and Workstations. This has provided an opportunity to review both central timing systems and to come up with common solutions. The result was, amongst others, the design of a unique timing module, called TG8. The TG8 is a multipurpose VME module, which receives messages distributed over a timing network. These messages include timing information, clock plus calendar and telegrams instructing the CERN accelerators on the characteristics of the next beam to be produced. The TG8 compares incoming messages with up to 256 programmed actions. An action consists of two parts, a trigger which matches an incoming message and what to do when the match occurs. The latter part may optionally create an output pulse on one of the eight output channels and/or a bus interrupt, both with programmable delay and telegram conditioning. (author)

  20. Electro-optic modulator with ultra-low residual amplitude modulation for frequency modulation and laser stabilization.

    Science.gov (United States)

    Tai, Zhaoyang; Yan, Lulu; Zhang, Yanyan; Zhang, Xiaofei; Guo, Wenge; Zhang, Shougang; Jiang, Haifeng

    2016-12-01

    The reduction of the residual amplitude modulation (RAM) induced by electro-optic modulation is essential for many applications of frequency modulation spectroscopy requiring a lower system noise floor. Here, we demonstrate a simple passive approach employing an electro-optic modulator (EOM) cut at Brewster's angle. The proposed EOM exhibits a RAM of a few parts per million, which is comparable with that achieved by a common EOM under critical active temperature and bias voltage controls. The frequency instability of a 10 cm cavity-stabilized laser induced by the RAM effect of the proposed EOM is below 3×10-17 for integration times from 1 to 1000 s, and below 4×10-16 for comprehensive noise contributions for integration times from 1 to 100 s.

  1. Design and Delivery of Technical Module for the Business Intelligence Course

    Science.gov (United States)

    Wang, Shouhong; Wang, Hai

    2013-01-01

    IS programs are increasingly being called on to offer courses in business intelligence. This article presents the pedagogical design and the delivery method of a practicable technical module for a non-technically oriented Business Intelligence course. It is a tutorial for the instructors who wish to incorporate a practical technical element in…

  2. Bellman's GAP--a language and compiler for dynamic programming in sequence analysis.

    Science.gov (United States)

    Sauthoff, Georg; Möhl, Mathias; Janssen, Stefan; Giegerich, Robert

    2013-03-01

    Dynamic programming is ubiquitous in bioinformatics. Developing and implementing non-trivial dynamic programming algorithms is often error prone and tedious. Bellman's GAP is a new programming system, designed to ease the development of bioinformatics tools based on the dynamic programming technique. In Bellman's GAP, dynamic programming algorithms are described in a declarative style by tree grammars, evaluation algebras and products formed thereof. This bypasses the design of explicit dynamic programming recurrences and yields programs that are free of subscript errors, modular and easy to modify. The declarative modules are compiled into C++ code that is competitive to carefully hand-crafted implementations. This article introduces the Bellman's GAP system and its language, GAP-L. It then demonstrates the ease of development and the degree of re-use by creating variants of two common bioinformatics algorithms. Finally, it evaluates Bellman's GAP as an implementation platform of 'real-world' bioinformatics tools. Bellman's GAP is available under GPL license from http://bibiserv.cebitec.uni-bielefeld.de/bellmansgap. This Web site includes a repository of re-usable modules for RNA folding based on thermodynamics.

  3. Photovoltaic Subcontract Program

    Energy Technology Data Exchange (ETDEWEB)

    Surek, Thomas; Catalano, Anthony

    1993-03-01

    This report summarizes the fiscal year (FY) 1992 progress of the subcontracted photovoltaic (PV) research and development (R D) performed under the Photovoltaic Advanced Research and Development Project at the National Renewable Energy Laboratory (NREL)-formerly the Solar Energy Research Institute (SERI). The mission of the national PV program is to develop PV technology for large-scale generation of economically competitive electric power in the United States. The technical sections of the report cover the main areas of the subcontract program: the Crystalline Materials and Advanced Concepts project, the Polycrystalline Thin Films project, Amorphous Silicon Research project, the Photovoltaic Manufacturing Technology (PVMaT) project, PV Module and System Performance and Engineering project, and the PV Analysis and Applications Development project. Technical summaries of each of the subcontracted programs provide a discussion of approaches, major accomplishments in FY 1992, and future research directions.

  4. Guidance system operations plan for manned LM earth orbital and lunar missions using program luminary 1E. Section 2: Data links

    Science.gov (United States)

    Hamilton, M. H.

    1972-01-01

    Data links for the guidance system of manned lunar module orbital and lunar missions are presented. Subjects discussed are: (1) digital uplink to lunar module, (2) lunar module liftoff time increment, (3) lunar module contiguous block update, (4) lunar module scatter update, (5) lunar module digital downlink, and (6) absolute addresses for update program.

  5. Environmental and health aspects of copper-indium-diselenide thin-film photovoltaic modules

    International Nuclear Information System (INIS)

    Steinberger, H.; Thumm, W.; Freitag, R.; Moskowitz, P.D.; Chapin, R.

    1994-01-01

    Copper-indium-diselenide (CIS) is a semiconductor compound that can be used to produce thin-film photovoltaic modules. There is on-going research being conducted by various federal agencies and private industries to demonstrate the commercial viability of this material. Because this is a new technology, and because scant information about the health and environmental hazards associated with the use of this material is available, studies have been initiated to characterize the environmental mobility and environmental toxicology of this compound. The objective of these studies is to identify the environmental and health hazards associated with the production, use, and disposal of CIS thin-film photovoltaic modules. The program includes both experimental and theoretical components. Theoretical studies are being undertaken to estimate material flows through the environment for a range of production options as well as use and disposal scenarios. The experimental programs characterize the physical, chemical e.g. leachability and biological parameters e.g. EC 50 in daphnia and algae, and feeding studies in rats

  6. Significantly High Modulation Efficiency of Compact Graphene Modulator Based on Silicon Waveguide.

    Science.gov (United States)

    Shu, Haowen; Su, Zhaotang; Huang, Le; Wu, Zhennan; Wang, Xingjun; Zhang, Zhiyong; Zhou, Zhiping

    2018-01-17

    We theoretically and experimentally demonstrate a significantly large modulation efficiency of a compact graphene modulator based on a silicon waveguide using the electro refractive effect of graphene. The modulation modes of electro-absorption and electro-refractive can be switched with different applied voltages. A high extinction ratio of 25 dB is achieved in the electro-absorption modulation mode with a driving voltage range of 0 V to 1 V. For electro-refractive modulation, the driving voltage ranges from 1 V to 3 V with a 185-pm spectrum shift. The modulation efficiency of 1.29 V · mm with a 40-μm interaction length is two orders of magnitude higher than that of the first reported graphene phase modulator. The realisation of phase and intensity modulation with graphene based on a silicon waveguide heralds its potential application in optical communication and optical interconnection systems.

  7. The DECADE performance assessment program

    International Nuclear Information System (INIS)

    Weber, B.V.; Ottinger, P.F.; Commisso, R.J.; Thompson, J.; Rowley, J.E.; Filios, P.; Babineau, M.A.

    1996-01-01

    Previous analyses of DECADE Module 1 experiments indicated significant current loss between the plasma opening switch (POS) and an electron-beam load. A program was initiated to diagnose and improve the power flow to assess the performance of a multi-module DECADE system. Power flow measurements between the POS and load indicate high vacuum flow, distributed current loss and azimuthal asymmetries. A decreased load impedance reduces the fraction of the load current flowing in vacuum. Improved plasma source symmetry reduces losses near the load for long conduction times. Increased POS impedance is required to significantly improve the power coupling to the load. (author). 6 figs., 9 refs

  8. The DECADE performance assessment program

    Energy Technology Data Exchange (ETDEWEB)

    Weber, B V; Ottinger, P F; Commisso, R J [Naval Research Lab., Washington, DC (United States). Plasma Physics Div.; Goyer, J R; Kortbawi, D [Physics International Co., Berkeley, CA (United States); Thompson, J [Maxwell Labs., San Diego, CA (United States); Rowley, J E; Filios, P [Defense Nuclear Agency, Alexandria, VA (United States); Babineau, M A [Sverdlup Technology, Tullahoma, TN (United States)

    1997-12-31

    Previous analyses of DECADE Module 1 experiments indicated significant current loss between the plasma opening switch (POS) and an electron-beam load. A program was initiated to diagnose and improve the power flow to assess the performance of a multi-module DECADE system. Power flow measurements between the POS and load indicate high vacuum flow, distributed current loss and azimuthal asymmetries. A decreased load impedance reduces the fraction of the load current flowing in vacuum. Improved plasma source symmetry reduces losses near the load for long conduction times. Increased POS impedance is required to significantly improve the power coupling to the load. (author). 6 figs., 9 refs.

  9. Evolution of interprofessional learning: Dalhousie University's "From Family Violence to Health" module.

    Science.gov (United States)

    Johnston, Grace M; Ryding, Helen A; Campbell, Lindsay M

    2003-11-01

    At Dalhousie University, interprofessional (IP) learning modules are used to help future health care professionals learn to work together in resolving complex problems. One module, "From Family Violence to Health," features the role of dental professionals. This paper describes the evolution of this module from the year 2000. By February 2003, 1,182 students from 15 health care professions had completed the module. Qualitative evaluation in years 1 and 2 of the program (2000 and 2001) revealed that, before participating in the IP module, many students were able to identify a role for themselves in the recognition of family violence and knew their responsibility to report incidents. However, after participating in the module, they had a greater understanding of the reporting of family violence, a more comprehensive and supportive perspective, increased recognition of how health care professionals could work together and improved awareness of the roles of other professions. In a quantitative evaluation in year 3 (2002), mean student ratings on a scale of 1 to 5 indicated that the IP module was relevant (4.2), increased their understanding of family violence (4.0), and had some impact in promoting IP learning (3.8). As health care delivery becomes more focused on care teams and system thinking, the provision of IP training is expected to increase. The Dalhousie University IP modules (available at http://www.dal.ca/~fhp/ipl/index.html) address health and social problems for which it is critical that health care and other professionals work together. Feedback from practitioners on the development of IP education is welcomed, particularly with regard to the IP module addressing family violence.

  10. Development of object oriented program `SONSHO` for strength evaluation. Manual of Version 4.0 program

    Energy Technology Data Exchange (ETDEWEB)

    Hosogai, Hiromi [Joyo Industries Co. Ltd., Tokai, Ibaraki (Japan); Kasahara, Naoto

    1998-07-01

    Object Oriented Program `SONSHO` predicts creep fatigue damage factors based on Elevated Temperature Structural Design Guide for `Monju` and other various procedures from stress classification data obtained from structural analysis results. From view point of program implementation, it is required that external programs interface and frequent revise from update of material and creep fatigue evaluation methods. Object oriented approach was continuously introduced to improve these aspects of the program. Version 4.0 has the following new functions. (1) Material strength library was implemented as an independent program module based on Microsoft Active X control and 32bitDLL technologies, which can be accessed by general Windows programs. (2) Self instruction system `Wizard` enables manual less operation. (3) Microsoft common object model (COM) was adopted for program interface, and this program can communicate with Excel sheet data on memory. Sonsho Ver.4.0 can work on Windows 95 or Windows NT4.0. Microsoft Visual Basic 5.0 (Enterprose Edition) and Microsoft FORTRAN Power Station 4.0 were adopted for program. (author)

  11. DIFFUSION - WRS system module number 7539 for solving a set of multigroup diffusion equations in one dimension

    International Nuclear Information System (INIS)

    Grimstone, M.J.

    1978-06-01

    The WRS Modular Programming System has been developed as a means by which programmes may be more efficiently constructed, maintained and modified. In this system a module is a self-contained unit typically composed of one or more Fortran routines, and a programme is constructed from a number of such modules. This report describes one WRS module, the function of which is to solve a set of multigroup diffusion equations for a system represented in one-dimensional plane, cylindrical or spherical geometry. The information given in this manual is of use both to the programmer wishing to incorporate the module in a programme, and to the user of such a programme. (author)

  12. The Karlsruhe program system KAPROS. Pt. 2

    International Nuclear Information System (INIS)

    Bachmann, H.; Kleinheins, S.

    1976-07-01

    The system nucleus of the Karlsruhe modular program system KAPROS is described from the point of view of the system programmer. In short reviews it is explained, how the module management, the data management, the buffer management, the error handling and the statistics work. The tables, the datasets, the routines and the commons of the system nucleus as well as some utility programs for the handling of system datasets are explained in full detail. The program listening of the system nucleus belongs to this documentation as a separate appendix. (orig.) [de

  13. Creation of an online multimedia radiology module access to Internet

    International Nuclear Information System (INIS)

    Alejo, J.P.; Vega, J.M.; Perez, R.

    1996-01-01

    Using freely distributed programs, we have created a radiology data server in the world wide web (WWW) system, which includes among its services a radiological teaching module developed entirely in Spanish. This server is linked to Internet, the extensive worldwide computer network, to which WWW subscribers have access. The data is presented in hypertext and hypermedia format. (Author) 9 refs

  14. Self-Inhibiting Modules Can Self-Organize as a Brain of a Robot: A Conjecture

    Directory of Open Access Journals (Sweden)

    J. Negrete-Martínez

    2006-01-01

    Full Text Available In this article we describe a new robot control architecture on the basis of self-organization of self-inhibiting modules. The architecture can generate a complex behaviour repertoire. The repertoire can be performance-enhanced or increased by modular poly-functionality and/or by addition of new modules. This architecture is illustrated in a robot consisting of a car carrying an arm with a grasping tool. In the robot, each module drives either a joint motor or a pair of wheel motors. Every module estimates the distance from a sensor placed in the tool to a beacon. If the distance is smaller than a previously measured distance, the module drives its motor in the same direction of its prior movement. If the distance is larger, the next movement will be in the opposite direction; but, if the movement produces no significant change in distance, the module self-inhibits. A self-organization emerges: any module can be the next to take control of the motor activity of the robot once one module self-inhibits. A single module is active at a given time. The modules are implemented as computer procedures and their turn for participation scheduled by an endless program. The overall behaviour of the robot corresponds to a reaching attention behaviour. It is easily switched to a running-away attention behaviour by changing the sign of the same parameter in each module. The addition of a “sensor-gain attenuation reflex” module and of a “light-orientation reflex” module provides an increase of the behavioural attention repertoire and performance enhancement. Since scheduling a module does not necessarily produce its sustained intervention, the architecture of the “brain” is actually providing action induction rather than action selection.

  15. RSYST: short description of the modules

    International Nuclear Information System (INIS)

    Ruehle, R.

    Since 1969, the modular system RSYST has been used for reactor and shielding calculations. A data base managed by a central program, data blocks containing structure descriptions, and hierarchical linking of data blocks enable flexible management of all data. Module sequences are formulated using a user command language. The language features logical branches, variables and arithmetic expressions. Sections of the user language may be stored in the data base and activated at any time. Presently, an interactive version of the system is developed. It supports basic operations and interactive input checking on a front end computer

  16. Pengaruh Fundamental Safe Work Practice Terhadap Pencegahan Kecelakaan Kerja Bagian Workover di PT. ACS Duri

    Directory of Open Access Journals (Sweden)

    M. Saifullah

    2012-05-01

    Full Text Available PT. Asrindo Citraseni Satria (ACS is a company engaged in oil and gas and is a sub contractor PT.CPI. PT. ACS has implemented FSWP whose objective which is to identify, assess, reduce, control or eliminate the risks associated with the work, but until now there is still a work accident that occurred even in small quantities. The author would like to know about the effect of application of the section Fundamental Safe Work Practice (FSWP can prevent the accident in workover PT. ACS Duri. This research uses quantitative analytical survey, with the design of Cross Sectional conducted from May to June 2012 with a large sample of 122 of the 360 people who work in the workover. Samples were taken by using a system Accidental Sampling, and the data processed using a computer program to analyze the independent variables in the form of application as well as the dependent variable is FSWP occupational accidents and tested using Chi-square. The results showed that, the application of FSWP can prevent accidents which includes Standard Operating Procedure (SOP with the value of P = 0.01 is smaller than the value of α = 0.05 that means there are a significant correlation between the application of SOP with workplace accidents, PTW with a value of P = 0.02 is more smaller than the value of α = 0.05 means that there are significant correlation between the application of Permit To Work (PTW accidents, and tagged with a value of P = 0.01 is smaller than the value of α= 0.05 means there is a significant correlation between the application of Log Out/Tag Out (LOTO by accident. It was concluded that, the application of FSWP can reduce / reduce the number of occupational accidents in the workover, and is expected for the management of HES to improving the knowledge for employee about the aspects of FSWP (SWA, Hazard Analysis, SOP, Access Control, PPE, MSDS, Housekeeping, PTW & Other Safe Work Practices.

  17. Scheduling language and algorithm development study. Volume 2: Use of the basic language and module library

    Science.gov (United States)

    Chamberlain, R. A.; Cornick, D. E.; Flater, J. F.; Odoherty, R. J.; Peterson, F. M.; Ramsey, H. R.; Willoughby, J. K.

    1974-01-01

    The capabilities of the specified scheduling language and the program module library are outlined. The summary is written with the potential user in mind and, therefore, provides maximum insight on how the capabilities will be helpful in writing scheduling programs. Simple examples and illustrations are provided to assist the potential user in applying the capabilities of his problem.

  18. A study on development of monitoring and assessment module for sites

    International Nuclear Information System (INIS)

    Park, Se Moon; Yoon, Bong Yo; Kim, Dae Jung; Park, Joo Wan; Kim, Chang Lak

    2006-01-01

    As the development of total management systems for sites along with site environmental information is becoming standard, the system known as the Site Information and Total Environmental database management System (SITES) has been developed over the last two years. The first result was a database management system for storing data obtained from facilities, and a site characterization in addition to an environmental assessment of a site. The SITES database is designed to be effective and practical for use with facility management and safety assessment in relation to Geographic Information Systems. SITES is a total management program, which includes its database, its data analysis system required for site characterization, a safety assessment modeling system and an environment monitoring system. I can contribute to the institutional management of the facility and to its safety reassessment. SITES is composed of two main modules: the SITES Database Module (SDM) and the Monitoring and Assessment (M and A) module. The M and A module is subdivided into two sub-modules: the Safety Assessment System (SAS) and the Site Environmental Monitoring System (SEMS). SAS controls the data (input and output) from the SITES DB for the site safety assessment, whereas SEMS controls the data obtained from the records of the measuring sensors and facilities. The on-line site and environmental monitoring data is managed in SEMS. The present paper introduces the procedure and function of the M and A modules

  19. Weakly Coretractable Modules

    Science.gov (United States)

    Hadi, Inaam M. A.; Al-aeashi, Shukur N.

    2018-05-01

    If R is a ring with identity and M is a unitary right R-module. Here we introduce the class of weakly coretractable module. Some basic properties are investigated and some relationships between these modules and other related one are introduced.

  20. Development and Implementation of High School Chemistry Modules Using Touch-Screen Technologies

    Science.gov (United States)

    Lewis, Maurica S.; Zhao, Jinhui; Montclare, Jin Kim

    2012-01-01

    Technology was employed to motivate and captivate students while enriching their in-class education. An outreach program is described that involved college mentors introducing touch-screen technology into a high school chemistry classroom. Three modules were developed, with two of them specifically tailored to encourage comprehension of molecular…

  1. Promoting Evidence-Based Practices: New Teaching Module for Early Childhood Teacher Educators

    Science.gov (United States)

    Young Children, 2009

    2009-01-01

    Linda Halgunseth, head of NAEYC's Office of Applied Research (OAR), tells readers about Child Care and Early Education Research Connections, a Web site (www.researchconnections.org/teaching_modules) to help teacher educators integrate knowledge about evidence-based practices into teacher education programs. In addition, the article touts the…

  2. SNOOP module CAMAC interface to the 168/E microprocessor

    International Nuclear Information System (INIS)

    Bernstein, D.; Carroll, J.T.; Mitnick, V.H.; Paffrath, L.; Parker, D.B.

    1979-10-01

    A pair of 168/E microprocessors will be used to meet the realtime computing requirements of the SLAC Hybrid Facility. A SNOOP module and 168/E Interface provide the link between the host computer and the microprocessors. By eavesdropping on normal CAMAC read operations, the SNOOP provides a direct data transfer from CAMAC to microprocessor memory. The host computer controls the processors using standard CAMAC programmed I/O to the SNOOP

  3. Outcome evaluation of a structured educational wellness program in patients with severe mental illness.

    Science.gov (United States)

    Lindenmayer, Jean-Pierre; Khan, Anzalee; Wance, Deborah; Maccabee, Neta; Kaushik, Sashank; Kaushik, Saurabh

    2009-10-01

    Obesity is increasing at an alarming rate in the United States, as is the obesity rate in patients with schizophrenia. Our study retrospectively evaluated the effectiveness of the Solutions for Wellness and Team Solutions programs, 2 structured educational patient programs, and evaluated the effects on obesity and other metabolic markers in a large, naturalistic inpatient sample. Between September 18, 2006, and September 15, 2007, 275 inpatients with DSM-IV-TR-diagnosed chronic mental illness admitted to a tertiary care psychiatric facility were included in the 36-week comprehensive and manualized educational program for healthy lifestyles for patients with chronic mental illness incorporating psychoeducational small-group curricula. Patients were tested before and after each of three 12-week group periods by 30 knowledge-assessment questions, and metabolic markers were recorded at baseline, midpoint, and endpoint. Of the 275 included inpatients, 50.5% completed more than 5 modules, 20.4% completed less than or equal to 2 or fewer modules, and 5.1% completed all 11 modules. Significant increases in scores were observed for 7 of the 11 modules in the knowledge assessments (P /=30 (indicating obesity) at the start of the program. There was a significant mean weight loss of 4.88 lb (P = .035) together with a significant decrease in mean BMI (P = .045). Patients with diabetes showed a reduction in mean weight of 5.98 lb. Significant reductions were observed in glucose and triglyceride levels (both P values (r = 0.56, P = .001). We found that a structured wellness program using a psychoeducational curriculum can be successfully implemented in a large, naturalistic psychiatric setting with unselected, chronically mentally ill inpatients. Results may help both clinicians and hospital managers to implement similar programs or to include successful components in existing programs for psychiatric patients. Copyright 2009 Physicians Postgraduate Press, Inc.

  4. Connection and record programs, used for the PM-6 peripheral computer

    International Nuclear Information System (INIS)

    Karabutova, N.E.; Tikhomirova, I.N.

    1976-01-01

    ''Pochta'' monitor program is described which is intended for the organization of an inter-program communication of channel and monitor modules of PM-6 peripheral computer. Protocol programs ''Protocol-Consule'' and ''Protocol'' are considered. Those are used for the printout of protocol texts with typewriters and teleprinters. ''Recording'' standard routine is given, which is meant for code translation. Detailed instructions are presented on utilization of all the above-mentioned programs

  5. A Self-Instructional Course in Student Financial Aid Administration. Module 2--Federal Student Financial Aid: History & Current Sources. Second Edition.

    Science.gov (United States)

    Washington Consulting Group, Inc., Washington, DC.

    The second of 17 modules in a self-instructional course on student financial aid administration, this module offers novice financial aid administrators and other institutional personnel a systematic introduction to the management of federal financial aid programs authorized by the Higher Education Act Title IV. It traces the history of federal…

  6. PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid M

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    2000-02-14

    This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''M''. The Appendices contains copies of the printouts of these software programs.

  7. PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid N

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This document describe the software programs for the Programmable Logic Controller and the Datable Access Module for Pumping Instrumentation and Control skid ''N''. The Appendices contains copies of the printouts of these software programs. This document describes the software programs for the Allen-Bradley SLC 500 programmable logic controller (PLC) and the Allen-Bradley DTAM PLUS operator interface module used on Pumping Instrumentation and Control (PIC) skid ''N''. The software programs for the SLC 500 and DTAM Plus are based on the core programs provided by Allen-Bradley. The PLC and DTAM software programs on skid ''D'' for SX-104 are the baseline programs. These baselines have been tailored for U-farm skids. The skid ''N'' program for U-109 is similar to the skid ''M'' program for U-102. An Acceptance Test Procedure (ATP) and an Operational Test Procedure (OTP) verify that the software programs meet the specific requirements for U-109 pumping. This document represents the final PLC and DTAM programs for PIC skid ''N'' at U-109. These programs were printed out after the performance of the OTP. The OTP acts as the final qualification test for the software programs. Functional requirements and details of the PLC ladder logic are described in this document. The final programs entered into the PLC and DTAM Plus are included as Appendices to this document

  8. Counter Trafficking System Development "Analysis Training Program"

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, Dennis C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2010-12-01

    This document will detail the training curriculum for the Counter-Trafficking System Development (CTSD) Analysis Modules and Lesson Plans are derived from the United States Military, Department of Energy doctrine and Lawrence Livermore National Laboratory (LLNL), Global Security (GS) S Program.

  9. System of programming units for the K556RT4 and K556RT5 fixed programmed memory devices

    International Nuclear Information System (INIS)

    Bobkov, S.G.; Ermolin, Yu.V.; Kantserov, V.A.; Strigin, V.B.

    1983-01-01

    The programming system of constant programmable memory devices K556RT4 and K556RT5 that consist of two units (a programming device and an electrothermotraining unit) is described. The modules are made in the KAMAK standard. The programming device takes up 2 normal places, while the electrothermotraining block takes up 1 place. As information recording is done using a computer the time for programming is reduced and the possibility of errors is limited as compared with the manual method. The computer introduces the whole word to be recorded, not the separate parts, in the programming device. The transition to a new digit of a given word in the programming device is done automatically. This reduces the expense of computer time and accelerates the programming of microdiagrams

  10. SCALPLO, Plotting of Flux Output from SCALE Program

    International Nuclear Information System (INIS)

    Hersman, A.; De Leege, P.F.A.; Hoogenboom, J.E.

    1993-01-01

    1 - Description of program or function: SCALPLO is a plot program, designed to plot flux, power and spectrum information. Data exchange between SCALE modules and SCALPLO is via CCCC-interface files. As not all modules can produce these files, there are special routines supplied with SCALPLO that can produce CCCC-like files. These routines can be included in the code and for XSDRPM, CITATION, ANISN and DOT, the place to include these routines is supplied. 2 - Method of solution: SCALPLO consists of two sections. Firstly the pre-processor, which selects and reads the required data. Secondly the plot section which produces the plot on the selected output device. 3 - Restrictions on the complexity of the problem: SCALPLO requires DISSPLA version 11.0 or higher. The choice of output device depends on the devices installed

  11. Design of Simulink module for dynamic reactivity simulation of marine reactor automatic control rod

    International Nuclear Information System (INIS)

    Chen Zhiyun; Luo Lei; Chen Wenzhen; Gui Xuewen

    2010-01-01

    The power of marine reactor varies frequently and acutely, which induces the frequent and acute adjustment of the automatic control rod. According to the characteristics of marine reactor and the problem of improper control rod reactivity insertion in previous literatures, the Simulink module for dynamic reactivity simulation of automatic control rod was designed and adopted as a sub-module of Simulink program for the fast calculation of the physical and thermal parameters of marine reactor. A typical dynamic process of the marine reactor was used as the benchmark, which indicates that the designed Simulink module is capable of the dynamic simulation of automatic control rod position and reactivity, and is adequate to the fast calculation of physic and thermal parameters. The Simulink module is of significant meaning to the simulation of the dynamic process of marine reactor and the fast calculation of the operating parameters. (authors)

  12. Assessment of a new undergraduate module in musculoskeletal medicine.

    Science.gov (United States)

    Queally, Joseph M; Cummins, Fionnan; Brennan, Stephen A; Shelly, Martin J; O'Byrne, John M

    2011-02-02

    Despite the high prevalence of musculoskeletal disorders seen by primary care physicians, numerous studies have demonstrated deficiencies in the adequacy of musculoskeletal education at multiple stages of medical education. The aim of this study was to assess a newly developed module in musculoskeletal medicine for use at European undergraduate level (i.e., the medical-school level). A two-week module in musculoskeletal medicine was designed to cover common musculoskeletal disorders that are typically seen in primary care. The module incorporated an integrated approach, including core lectures, bedside clinical examination, and demonstration of basic practical procedures. A previously validated examination in musculoskeletal medicine was used to assess the cognitive knowledge of ninety-two students on completion of the module. A historical control group (seventy-two students) from a prior course was used for comparison. The new module group (2009) performed significantly better than the historical (2006) control group in terms of score (62.3% versus 54.3%, respectively; p pass rate (38.4% versus 12.5%, respectively; p = 0.0002). In a subgroup analysis of the new module group, students who enrolled in the graduate entry program (an accelerated four-year curriculum consisting of students who have already completed an undergraduate university degree) were more likely to perform better in terms of average score (72.2% versus 57%, respectively; p pass rates (70.9% versus 21.4%, respectively; p paper represents an educational advance at undergraduate (i.e., medical-school) level as demonstrated by the improvement in scores in a validated examination. As pressure on medical curricula grows to accommodate advancing medical knowledge, it is important to continue to improve, assess, and consolidate the position of musculoskeletal medicine in contemporary medical education.

  13. Assessment and Evaluation of the Utah Master Naturalist Program: Implications for Targeting Audiences

    Science.gov (United States)

    Larese-Casanova, Mark

    2011-01-01

    The Utah Master Naturalist Program trains citizens who provide education, outreach, and service to promote citizen stewardship of natural resources within their communities. In 2007-2008, the Watersheds module of the program was evaluated for program success, and participant knowledge was assessed. Assessment and evaluation results indicated that…

  14. pypk - A Python extension module to handle chemical kinetics in plasma physics modeling

    Directory of Open Access Journals (Sweden)

    2008-06-01

    Full Text Available PLASMAKIN is a package to handle physical and chemical data used in plasma physics modeling and to compute gas-phase and gas-surface kinetics data: particle production and loss rates, photon emission spectra and energy exchange rates. A large number of species properties and reaction types are supported, namely: gas or electron temperature dependent collision rate coefficients, vibrational and cascade levels, evaluation of branching ratios, superelastic and other reverse processes, three-body collisions, radiation imprisonment and photoelectric emission. Support of non-standard rate coefficient functions can be handled by a user-supplied shared library.

    The main block of the PLASMAKIN package is a Fortran module that can be included in an user's program or compiled as a shared library, libpk. pypk is a new addition to the package and provides access to libpk from Python programs. It is build on top of the ctypes foreign function library module and is prepared to work with several Fortran compilers. However pypk is more than a wrapper and provides its own classes and functions taking advantage of Python language characteristics. Integration with Python tools allows substantial productivity gains on program development and insight on plasma physics problems.

  15. Basic Botany On-Line: A Training Tool for the Master Gardener Program.

    Science.gov (United States)

    VanDerZanden, Ann Marie; Rost, Bob; Eckel, Rick

    2002-01-01

    A noncredit, online training module on botany was offered to participants in the Oregon Master Gardener program. The 48 participants felt the module was a useful training tool. They also noted that the convenience of completing the material at their own pace and during a time that fit into their schedule. (SK)

  16. Graphical programming at Sandia National Laboratories

    International Nuclear Information System (INIS)

    McDonald, M.J.; Palmquist, R.D.; Desjarlais, L.

    1993-09-01

    Sandia has developed an advanced operational control system approach, called Graphical Programming, to design, program, and operate robotic systems. The Graphical Programming approach produces robot systems that are faster to develop and use, safer in operation, and cheaper overall than altemative teleoperation or autonomous robot control systems. Graphical Programming also provides an efficient and easy-to-use interface to traditional robot systems for use in setup and programming tasks. This paper provides an overview of the Graphical Programming approach and lists key features of Graphical Programming systems. Graphical Programming uses 3-D visualization and simulation software with intuitive operator interfaces for the programming and control of complex robotic systems. Graphical Programming Supervisor software modules allow an operator to command and simulate complex tasks in a graphic preview mode and, when acceptable, command the actual robots and monitor their motions with the graphic system. Graphical Programming Supervisors maintain registration with the real world and allow the robot to perform tasks that cannot be accurately represented with models alone by using a combination of model and sensor-based control

  17. Design and practice for a picture archiving and communication system based structured report module

    International Nuclear Information System (INIS)

    Tian Junzhang; Jiang Guihua; Zheng Liyin; Ou Jingchai; Wu Pingyang; Hong Wensong; Jin Lin; Huang Dajiang; Zhang Xuelin

    2004-01-01

    Objective: To design and explore structured report module based on PACS, and to make diagnostic reports with pictures and words in application of computer implementing synchronous transmission of reports and pictures. Methods: 1000 Mb trunk net was adopted in PACS and 100 Mb was exchanged on tabletop. Structured report was designed with six function modules including basic item area, image sign area, diagnostic impression area, advice area, signature area, and picture area by application of programming language such as Delphi 6.0 and VC ++ 6.0. DICOM. Medical images or waveform were inserted directly in the diagnosis report through citing DICOM composite object. Basic function library was designed and constructed in whole system environment. Results: The structured report module based on PACS could structure image diagnosis report in inerrability structure in term of compute. The time and period of reports were shortened and utilization of report original datum were improved. Conclusion: The structured report module was in favor of promotion to combine with clinic teaching and scientific research. The quality and efficiency of image diagnosis work were raised by structured report module

  18. Development of Thermal-hydraulic Analysis Methodology for Multi-module Breeding Blankets in K-DEMO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Geon-Woo; Lee, Jeong-Hun; Park, Goon-Cherl; Cho, Hyoung-Kyu [Seoul National University, Seoul (Korea, Republic of); Im, Kihak [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    In this paper, the purpose of the analyses is to extend the capability of MARS-KS to the entire blanket system which includes a few hundreds of single blanket modules. Afterwards, the plan for the whole blanket system analysis using MARS-KS is introduced and the result of the multiple blanket module analysis is summarized. A thermal-hydraulic analysis code for a nuclear reactor safety, MARS-KS, was applied for the conceptual design of the K-DEMO breeding blanket thermal analysis. Then, a methodology to simulate multiple blanket modules was proposed, which uses a supervisor program to handle each blanket module individually at first and then distribute the flow rate considering pressure drops arises in each module. For a feasibility test of the proposed methodology, 10 outboard blankets in a toroidal field sector were simulated, which are connected with each other through the inlet and outlet common headers. The calculation results of flow rates, pressure drops, and temperatures showed the validity of the calculation and thanks to the parallelization using MPI, almost linear speed-up could be obtained.

  19. Development of DKB ETL module in case of data conversion

    Science.gov (United States)

    Kaida, A. Y.; Golosova, M. V.; Grigorieva, M. A.; Gubin, M. Y.

    2018-05-01

    Modern scientific experiments involve the producing of huge volumes of data that requires new approaches in data processing and storage. These data themselves, as well as their processing and storage, are accompanied by a valuable amount of additional information, called metadata, distributed over multiple informational systems and repositories, and having a complicated, heterogeneous structure. Gathering these metadata for experiments in the field of high energy nuclear physics (HENP) is a complex issue, requiring the quest for solutions outside the box. One of the tasks is to integrate metadata from different repositories into some kind of a central storage. During the integration process, metadata taken from original source repositories go through several processing steps: metadata aggregation, transformation according to the current data model and loading it to the general storage in a standardized form. The R&D project of ATLAS experiment on LHC, Data Knowledge Base, is aimed to provide fast and easy access to significant information about LHC experiments for the scientific community. The data integration subsystem, being developed for the DKB project, can be represented as a number of particular pipelines, arranging data flow from data sources to the main DKB storage. The data transformation process, represented by a single pipeline, can be considered as a number of successive data transformation steps, where each step is implemented as an individual program module. This article outlines the specifics of program modules, used in the dataflow, and describes one of the modules developed and integrated into the data integration subsystem of DKB.

  20. Directed network modules

    International Nuclear Information System (INIS)

    Palla, Gergely; Farkas, Illes J; Pollner, Peter; Derenyi, Imre; Vicsek, Tamas

    2007-01-01

    A search technique locating network modules, i.e. internally densely connected groups of nodes in directed networks is introduced by extending the clique percolation method originally proposed for undirected networks. After giving a suitable definition for directed modules we investigate their percolation transition in the Erdos-Renyi graph both analytically and numerically. We also analyse four real-world directed networks, including Google's own web-pages, an email network, a word association graph and the transcriptional regulatory network of the yeast Saccharomyces cerevisiae. The obtained directed modules are validated by additional information available for the nodes. We find that directed modules of real-world graphs inherently overlap and the investigated networks can be classified into two major groups in terms of the overlaps between the modules. Accordingly, in the word-association network and Google's web-pages, overlaps are likely to contain in-hubs, whereas the modules in the email and transcriptional regulatory network tend to overlap via out-hubs

  1. Decoupled Modulation Control

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Shaobu; Huang, Renke; Huang, Zhenyu; Diao, Ruisheng

    2016-06-03

    The objective of this research work is to develop decoupled modulation control methods for damping inter-area oscillations with low frequencies, so the damping control can be more effective and easier to design with less interference among different oscillation modes in the power system. A signal-decoupling algorithm was developed that can enable separation of multiple oscillation frequency contents and extraction of a “pure” oscillation frequency mode that are fed into Power System Stabilizers (PSSs) as the modulation input signals. As a result, instead of introducing interferences between different oscillation modes from the traditional approaches, the output of the new PSS modulation control signal mainly affects only one oscillation mode of interest. The new decoupled modulation damping control algorithm has been successfully developed and tested on the standard IEEE 4-machine 2-area test system and a minniWECC system. The results are compared against traditional modulation controls, which demonstrates the validity and effectiveness of the newly-developed decoupled modulation damping control algorithm.

  2. Classes of modules

    CERN Document Server

    Dauns, John

    2006-01-01

    Because traditional ring theory places restrictive hypotheses on all submodules of a module, its results apply only to small classes of already well understood examples. Often, modules with infinite Goldie dimension have finite-type dimension, making them amenable to use with type dimension, but not Goldie dimension. By working with natural classes and type submodules (TS), Classes of Modules develops the foundations and tools for the next generation of ring and module theory. It shows how to achieve positive results by placing restrictive hypotheses on a small subset of the complement submodules, Furthermore, it explains the existence of various direct sum decompositions merely as special cases of type direct sum decompositions. Carefully developing the foundations of the subject, the authors begin by providing background on the terminology and introducing the different module classes. The modules classes consist of torsion, torsion-free, s[M], natural, and prenatural. They expand the discussion by exploring...

  3. Comparaison of Atlas Tilecal module

    CERN Document Server

    Batusov1, V; Gayde, J C; Khubua, J I; Lasseur, C; Lyablin, M V; Miralles-Verge, L; Nessi, Marzio; Rusakovitch, N A; Sissakian, A N; Topilin, N D

    2002-01-01

    The high precision assembly of a large experimental set-ups is of a principal necessity for the successful execution of the forthcoming LHC research program in the TeV-beams. The creation of an adequate Survey&Control METROLOGY METHODs are an essential part of the detector construction scenario. This work contains the dimension measurement data for ATLAS hadron calorimeter MODULE#8 (6m long, 22tons) which were obtained by LASER and by PHOTOGRAMMETRY methods. The comparative data analysis demonstrates the measurements agreement within ±70mm. It means these two clearly independent methods can be combined and lead to the rise of a new generation engineering culture: high precision metrology when precision assembly of large scale massive objects.

  4. Optimizing ROOT’s Performance Using C++ Modules

    Science.gov (United States)

    Vassilev, Vassil

    2017-10-01

    ROOT comes with a C++ compliant interpreter cling. Cling needs to understand the content of the libraries in order to interact with them. Exposing the full shared library descriptors to the interpreter at runtime translates into increased memory footprint. ROOT’s exploratory programming concepts allow implicit and explicit runtime shared library loading. It requires the interpreter to load the library descriptor. Re-parsing of descriptors’ content has a noticeable effect on the runtime performance. Present state-of-art lazy parsing technique brings the runtime performance to reasonable levels but proves to be fragile and can introduce correctness issues. An elegant solution is to load information from the descriptor lazily and in a non-recursive way. The LLVM community advances its C++ Modules technology providing an io-efficient, on-disk representation capable to reduce build times and peak memory usage. The feature is standardized as a C++ technical specification. C++ Modules are a flexible concept, which can be employed to match CMS and other experiments’ requirement for ROOT: to optimize both runtime memory usage and performance. Cling technically “inherits” the feature, however tweaking it to ROOT scale and beyond is a complex endeavor. The paper discusses the status of the C++ Modules in the context of ROOT, supported by few preliminary performance results. It shows a step-by-step migration plan and describes potential challenges which could appear.

  5. Fertilizing ROSES through the STEM: Interdisciplinary Modules as Pre-service Research Experiences for Secondary STEM Educators (IMPRESS-Ed)

    Science.gov (United States)

    Magee, N. B.; Kavic, M.; Benoit, M. H.; Wiita, P.

    2011-12-01

    IMPRESS-Ed is a program designed to provide authentic summer research experiences in the space, earth, and atmospheric sciences for pre-service K-12 educators at The College of New Jersey (TCNJ). In 2011, the program involved five students and took place over eight weeks with recruitment occurring during the preceding academic year. The program was divided into two modules: A common core module and an individual mentored research experience. The common module consisted of three units focusing on data-driven pedagogical approaches in astrophysics, tectonophysics, and atmospheric science, respectively. The common module also featured training sessions in observational astronomy, and use of a 3D geowall and state of the art planetarium. Participants in the program are also offered the opportunity to utilize the available TCNJ facilities with their future students. Given that a large number of graduates from the TCNJ take positions in local New Jersey schools, the opportunity to make use of these facilities at a future time would be of great significance to them and their future students. The individual mentored research module matched student interests with potential projects. Research led by M.H. Benoit analyzed gravity data from the NASA-GRACE mission to find lithospheric density contrasts beneath the eastern US. A student working with N.B. Magee used data from NASA satellites CALIPSO, CloudSat, and AQUA-MODIS to study the dynamics of convective cloud tops. Research projects led by M. Kavic performed simulations to investigate the possibility of detecting superconducting cosmic strings using radio observations and also designed and constructed a radio interferometer based on the NASA's Radio-Jove program. P. Wiita supervised a research project studying star-forming regions of active galaxies through analysis of images from NASA's Hubble Space Telescope and GALEX. The research program was also incorporated into the framework of the TCNJ Mentored Undergraduate Summer

  6. Automatic generation of Fortran programs for algebraic simulation models

    International Nuclear Information System (INIS)

    Schopf, W.; Rexer, G.; Ruehle, R.

    1978-04-01

    This report documents a generator program by which econometric simulation models formulated in an application-orientated language can be transformed automatically in a Fortran program. Thus the model designer is able to build up, test and modify models without the need of a Fortran programmer. The development of a computer model is therefore simplified and shortened appreciably; in chapter 1-3 of this report all rules are presented for the application of the generator to the model design. Algebraic models including exogeneous and endogeneous time series variables, lead and lag function can be generated. In addition, to these language elements, Fortran sequences can be applied to the formulation of models in the case of complex model interrelations. Automatically the generated model is a module of the program system RSYST III and is therefore able to exchange input and output data with the central data bank of the system and in connection with the method library modules can be used to handle planning problems. (orig.) [de

  7. Determination of the KQclinfclin,Qmsr fmsr correction factors for detectors used with an 800 MU/min CyberKnife(®) system equipped with fixed collimators and a study of detector response to small photon beams using a Monte Carlo method.

    Science.gov (United States)

    Moignier, C; Huet, C; Makovicka, L

    2014-07-01

    In a previous work, output ratio (ORdet) measurements were performed for the 800 MU/min CyberKnife(®) at the Oscar Lambret Center (COL, France) using several commercially available detectors as well as using two passive dosimeters (EBT2 radiochromic film and micro-LiF TLD-700). The primary aim of the present work was to determine by Monte Carlo calculations the output factor in water (OFMC,w) and the [Formula: see text] correction factors. The secondary aim was to study the detector response in small beams using Monte Carlo simulation. The LINAC head of the CyberKnife(®) was modeled using the PENELOPE Monte Carlo code system. The primary electron beam was modeled using a monoenergetic source with a radial gaussian distribution. The model was adjusted by comparisons between calculated and measured lateral profiles and tissue-phantom ratios obtained with the largest field. In addition, the PTW 60016 and 60017 diodes, PTW 60003 diamond, and micro-LiF were modeled. Output ratios with modeled detectors (ORMC,det) and OFMC,w were calculated and compared to measurements, in order to validate the model for smallest fields and to calculate [Formula: see text] correction factors, respectively. For the study of the influence of detector characteristics on their response in small beams; first, the impact of the atomic composition and the mass density of silicon, LiF, and diamond materials were investigated; second, the material, the volume averaging, and the coating effects of detecting material on the detector responses were estimated. Finally, the influence of the size of silicon chip on diode response was investigated. Looking at measurement ratios (uncorrected output factors) compared to the OFMC,w, the PTW 60016, 60017 and Sun Nuclear EDGE diodes systematically over-responded (about +6% for the 5 mm field), whereas the PTW 31014 Pinpoint chamber systematically under-responded (about -12% for the 5 mm field). ORdet measured with the SFD diode and PTW 60003 diamond

  8. Digital front-end module (DFEM) series; Digital front end module (DFEM) series

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    The digital front-end module (DFEM) is a module in which the processes ranging from the reception of digitally modulated radiofrequencies to the output of digital IF (Intermediate Frequency) signals or data streams are integrated. Beginning with a module for the MCNS (Multimedia Cable Network System) cable modem which was the first module in this business field approved by the Cable Labs, U.S., Toshiba has developed a series of DFEMs for various digital media for satellites, ground waves, and CATV (Cable Television) systems. The series is characterized by (1) the serialization of DFEMs compatible with various digital modulation techniques such as 8 PSK (Phase Shift Keying), OFDM (Orthogonal Frequency Division Multiplexing), and 256 QAM (Quadrature Amplitude Modulation), (2) easy connection with digital circuits thanks to the high shielding effect, and (3) the achievement of smaller size, higher performance, and lower power consumption. (translated by NEDO)

  9. SU-C-201-06: Small Field Correction Factors for the MicroDiamond Detector in the Gamma Knife-Model C Derived Using Monte Carlo Methods

    International Nuclear Information System (INIS)

    Barrett, J C; Knill, C

    2016-01-01

    Purpose: To determine small field correction factors for PTW’s microDiamond detector in Elekta’s Gamma Knife Model-C unit. These factors allow the microDiamond to be used in QA measurements of output factors in the Gamma Knife Model-C; additionally, the results also contribute to the discussion on the water equivalence of the relatively-new microDiamond detector and its overall effectiveness in small field applications. Methods: The small field correction factors were calculated as k correction factors according to the Alfonso formalism. An MC model of the Gamma Knife and microDiamond was built with the EGSnrc code system, using BEAMnrc and DOSRZnrc user codes. Validation of the model was accomplished by simulating field output factors and measurement ratios for an available ABS plastic phantom and then comparing simulated results to film measurements, detector measurements, and treatment planning system (TPS) data. Once validated, the final k factors were determined by applying the model to a more waterlike solid water phantom. Results: During validation, all MC methods agreed with experiment within the stated uncertainties: MC determined field output factors agreed within 0.6% of the TPS and 1.4% of film; and MC simulated measurement ratios matched physically measured ratios within 1%. The final k correction factors for the PTW microDiamond in the solid water phantom approached unity to within 0.4%±1.7% for all the helmet sizes except the 4 mm; the 4 mm helmet size over-responded by 3.2%±1.7%, resulting in a k factor of 0.969. Conclusion: Similar to what has been found in the Gamma Knife Perfexion, the PTW microDiamond requires little to no corrections except for the smallest 4 mm field. The over-response can be corrected via the Alfonso formalism using the correction factors determined in this work. Using the MC calculated correction factors, the PTW microDiamond detector is an effective dosimeter in all available helmet sizes. The authors would like to

  10. SU-C-201-06: Small Field Correction Factors for the MicroDiamond Detector in the Gamma Knife-Model C Derived Using Monte Carlo Methods

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, J C [Wayne State University, Detroit, MI (United States); Karmanos Cancer Institute McLaren-Macomb, Clinton Township, MI (United States); Knill, C [Wayne State University, Detroit, MI (United States); Beaumont Hospital, Canton, MI (United States)

    2016-06-15

    Purpose: To determine small field correction factors for PTW’s microDiamond detector in Elekta’s Gamma Knife Model-C unit. These factors allow the microDiamond to be used in QA measurements of output factors in the Gamma Knife Model-C; additionally, the results also contribute to the discussion on the water equivalence of the relatively-new microDiamond detector and its overall effectiveness in small field applications. Methods: The small field correction factors were calculated as k correction factors according to the Alfonso formalism. An MC model of the Gamma Knife and microDiamond was built with the EGSnrc code system, using BEAMnrc and DOSRZnrc user codes. Validation of the model was accomplished by simulating field output factors and measurement ratios for an available ABS plastic phantom and then comparing simulated results to film measurements, detector measurements, and treatment planning system (TPS) data. Once validated, the final k factors were determined by applying the model to a more waterlike solid water phantom. Results: During validation, all MC methods agreed with experiment within the stated uncertainties: MC determined field output factors agreed within 0.6% of the TPS and 1.4% of film; and MC simulated measurement ratios matched physically measured ratios within 1%. The final k correction factors for the PTW microDiamond in the solid water phantom approached unity to within 0.4%±1.7% for all the helmet sizes except the 4 mm; the 4 mm helmet size over-responded by 3.2%±1.7%, resulting in a k factor of 0.969. Conclusion: Similar to what has been found in the Gamma Knife Perfexion, the PTW microDiamond requires little to no corrections except for the smallest 4 mm field. The over-response can be corrected via the Alfonso formalism using the correction factors determined in this work. Using the MC calculated correction factors, the PTW microDiamond detector is an effective dosimeter in all available helmet sizes. The authors would like to

  11. Performance improvement of charge trap flash memory by using a composition-modulated high-k trapping layer

    International Nuclear Information System (INIS)

    Tang Zhen-Jie; Li Rong; Yin Jiang

    2013-01-01

    A composition-modulated (HfO 2 ) x (Al 2 O3) 1−x charge trapping layer is proposed for charge trap flash memory by controlling the Al atom content to form a peak and valley shaped band gap. It is found that the memory device using the composition-modulated (HfO 2 ) x (Al 2 O 3 ) 1−x as the charge trapping layer exhibits a larger memory window of 11.5 V, improves data retention even at high temperature, and enhances the program/erase speed. Improvements of the memory characteristics are attributed to the special band-gap structure resulting from the composition-modulated trapping layer. Therefore, the composition-modulated charge trapping layer may be useful in future nonvolatile flash memory device application. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  12. A Toolchain to Produce Correct-by-Construction OCaml Programs

    OpenAIRE

    Filliâtre , Jean-Christophe; Gondelman , Léon; Paskevich , Andrei; Pereira , Mário; Melo De Sousa , Simão

    2018-01-01

    This paper presents a methodology to get correct-by-construction OCaml programs using the Why3 tool. First, a formal behavioral specification is given in the form of an OCaml module signature extended with type invariants and function contracts, in the spirit of JML. Second, an implementation is written in the programming language of Why3 and then verified with respect to the specification. Finally, an OCaml program is obtained by an automated translation. Our methodology is illustrated with ...

  13. Nuclear-fuel-cycle education: Module 1. Nuclear fuel cycle overview

    International Nuclear Information System (INIS)

    Eckhoff, N.D.

    1981-07-01

    This educational module is an overview of the nuclear-fule-cycle. The overview covers nuclear energy resources, the present and future US nuclear industry, the industry view of nuclear power, the International Nuclear Fuel Cycle Evaluation program, the Union of Concerned Scientists view of the nuclear-fuel-cycle, an analysis of this viewpoint, resource requirements for a model light water reactor, and world nuclear power considerations

  14. Bioresearch module design definition and space shuttle vehicle integration. Volume 3: Management and funding plan

    Science.gov (United States)

    1971-01-01

    A description is given of the proposed project organization, documentation and reports, project planning, direction and control, related experience and facilities, and cost estimate data and options for the implementation of the bioresearch module development program.

  15. DIMAC program user's manual

    International Nuclear Information System (INIS)

    Lee, Byoung Oon; Song, Tae Young

    2003-11-01

    DIMAC (A DIspersion Metallic fuel performance Analysis Code) is a computer program for simulating the behavior of dispersion fuel rods under normal operating conditions of HYPER. It computes the one-dimensional temperature distribution and the thermo-mechanical characteristics of fuel rod under the steady state operation condition, including the swelling and rod deformation. DIMAC was developed based on the experience of research reactor fuel. DIMAC consists of the temperature calculation module, the mechanical swelling calculation module, and the fuel deformation calculation module in order to predict the deformation of a dispersion fuel as a function of power history. Because there are a little of available U-TRU-Zr or TRU-Zr characteristics, the material data of U-Pu-Zr or Pu-Zr are used for those of U-TRU-Zr or TRU-Zr. This report is mainly intended as a user's manual for the DIMAC code. The general description on this code, the description on input parameter, the description on each subroutine, the sample problem and the sample input and partial output are written in this report

  16. DIMAC program user's manual

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byoung Oon; Song, Tae Young

    2003-11-01

    DIMAC (A DIspersion Metallic fuel performance Analysis Code) is a computer program for simulating the behavior of dispersion fuel rods under normal operating conditions of HYPER. It computes the one-dimensional temperature distribution and the thermo-mechanical characteristics of fuel rod under the steady state operation condition, including the swelling and rod deformation. DIMAC was developed based on the experience of research reactor fuel. DIMAC consists of the temperature calculation module, the mechanical swelling calculation module, and the fuel deformation calculation module in order to predict the deformation of a dispersion fuel as a function of power history. Because there are a little of available U-TRU-Zr or TRU-Zr characteristics, the material data of U-Pu-Zr or Pu-Zr are used for those of U-TRU-Zr or TRU-Zr. This report is mainly intended as a user's manual for the DIMAC code. The general description on this code, the description on input parameter, the description on each subroutine, the sample problem and the sample input and partial output are written in this repo0008.

  17. Relative injectivity and CS-modules

    Directory of Open Access Journals (Sweden)

    Mahmoud Ahmed Kamal

    1994-01-01

    Full Text Available In this paper we show that a direct decomposition of modules M⊕N, with N homologically independent to the injective hull of M, is a CS-module if and only if N is injective relative to M and both of M and N are CS-modules. As an application, we prove that a direct sum of a non-singular semisimple module and a quasi-continuous module with zero socle is quasi-continuous. This result is known for quasi-injective modules. But when we confine ourselves to CS-modules we need no conditions on their socles. Then we investigate direct sums of CS-modules which are pairwise relatively inective. We show that every finite direct sum of such modules is a CS-module. This result is known for quasi-continuous modules. For the case of infinite direct sums, one has to add an extra condition. Finally, we briefly discuss modules in which every two direct summands are relatively inective.

  18. Beam related response of in vivo diode detectors for external radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Baci, Syrja, E-mail: sbarci2013@gmail.com [Department of Physics, Faculty of Natural Sciences, University of Gjirokastra, “Eqrem Çabej” (Albania); Telhaj, Ervis [Department of Medical Physics, Hygeia Hospital Tirana (Albania); Malkaj, Partizan [Department of Physical Engineering, Polytechnic University, Tirana (Albania)

    2016-03-25

    In Vivo Dosimetry (IVD) is a set of methods used in cancer treatment clinics to determine the real dose of radiation absorbed by target volume in a patient’s body. IVD has been widely implemented in radiotherapy treatment centers and is now recommended part of Quality Assurance program by many International health and radiation organizations. Because of cost and lack of specialized personnel, IVD has not been practiced as yet, in Albanian radiotherapy clinics. At Hygeia Hospital Tirana, patients are irradiated with high energy photons generated by Elekta Synergy Accelerators. We have recently started experimenting with the purpose of establishing an IVD practice at this hospital. The first set of experiments was aimed at calibration of diodes that are going to be used for IVD. PMMA, phantoms by PTW were used to calibrate p – type Si, semiconductor diode dosimeters, made by PTW Freiburg for entrance dose. Response of the detectors is affected by energy of the beam, accumulated radiation dose, dose rate, temperature, angle against the beam axis, etc. Here we present the work done for calculating calibration factor and correction factors of source to surface distance, field size, and beam incidence for the entrance dose for both 6 MV photon beam and 18 MV photon beam. Dependence of dosimeter response was found to be more pronounced with source to surface distance as compared to other variables investigated.

  19. Beam related response of in vivo diode detectors for external radiotherapy

    International Nuclear Information System (INIS)

    Baci, Syrja; Telhaj, Ervis; Malkaj, Partizan

    2016-01-01

    In Vivo Dosimetry (IVD) is a set of methods used in cancer treatment clinics to determine the real dose of radiation absorbed by target volume in a patient’s body. IVD has been widely implemented in radiotherapy treatment centers and is now recommended part of Quality Assurance program by many International health and radiation organizations. Because of cost and lack of specialized personnel, IVD has not been practiced as yet, in Albanian radiotherapy clinics. At Hygeia Hospital Tirana, patients are irradiated with high energy photons generated by Elekta Synergy Accelerators. We have recently started experimenting with the purpose of establishing an IVD practice at this hospital. The first set of experiments was aimed at calibration of diodes that are going to be used for IVD. PMMA, phantoms by PTW were used to calibrate p – type Si, semiconductor diode dosimeters, made by PTW Freiburg for entrance dose. Response of the detectors is affected by energy of the beam, accumulated radiation dose, dose rate, temperature, angle against the beam axis, etc. Here we present the work done for calculating calibration factor and correction factors of source to surface distance, field size, and beam incidence for the entrance dose for both 6 MV photon beam and 18 MV photon beam. Dependence of dosimeter response was found to be more pronounced with source to surface distance as compared to other variables investigated.

  20. An IMRT dose distribution study using commercial verification software

    International Nuclear Information System (INIS)

    Grace, M.; Liu, G.; Fernando, W.; Rykers, K.

    2004-01-01

    Full text: The introduction of IMRT requires users to confirm that the isodose distributions and relative doses calculated by their planning system match the doses delivered by their linear accelerators. To this end the commercially available software, VeriSoft TM (PTW-Freiburg, Germany) was trialled to determine if the tools and functions it offered would be of benefit to this process. The CMS Xio (Computer Medical System) treatment planning system was used to generate IMRT plans that were delivered with an upgraded Elekta SL15 linac. Kodak EDR2 film sandwiched in RW3 solid water (PTW-Freiburg, Germany) was used to measure the IMRT fields delivered with 6 MV photons. The isodose and profiles measured with the film generally agreed to within ± 3% or ± 3 mm with the planned doses, in some regions (outside the IMRT field) the match fell to within ± 5%. The isodose distributions of the planning system and the film could be compared on screen and allows for electronic records of the comparison to be kept if so desired. The features and versatility of this software has been of benefit to our IMRT QA program. Furthermore, the VeriSoft TM software allows for quick and accurate, automated planar film analysis.Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  1. Conversational module-based simulation system as a human interface to versatile dynamic simulation of nuclear power plant

    International Nuclear Information System (INIS)

    Yoshikawa, H.; Nakaya, K.; Wakabayashi, J.

    1986-01-01

    A new conversational simulation system is proposed which aims at effective re-utilization of software resources as module database, and conducting versatile simulations easily by automatic module integration with the help of user-friendly interfaces. The whole simulation system is composed of the four parts: master module library and pre-compiler system as the core system, while module database management system and simulation execution support system for the user interfaces. Basic methods employed in the system are mentioned with their knowledge representation and the relationship with the human information processing. An example practice of an LMFBR reactor dynamic simulation by the system demonstrated its capability to integrate a large simulation program and the related input/output files automatically by a single user

  2. Dose evaluation of narrow-beam

    International Nuclear Information System (INIS)

    Goto, Shinichi

    1999-01-01

    Reliability of the dose from the narrow photon beam becomes more important since the single high-dose rate radiosurgery becoming popular. The dose evaluation for the optimal dose is difficult due to absence of lateral electronic equilibrium. Data necessary for treatment regimen are TMR (tissue maximum ratio), OCR (off center ratio) and S c,p (total scatter factor). The narrow-beam was 10 MV X-ray from Varian Clinac 2100C equipped with cylindrical Fischer collimator CBI system. Detection was performed by Kodak XV-2 film, a PTW natural diamond detector M60003, Scanditronics silicon detector EDD-5 or Fujitec micro-chamber FDC-9.4C. Phantoms were the water equivalent one (PTW, RW3), water one (PTW, MP3 system) and Wellhofer WP600 system. Factors above were actually measured to reveal that in the dose evaluation of narrow photon beam, TMR should be measured by micro-chamber, OCR, by film, and S c,p , by the two. The use of diamond detector was recommended for more precise measurement and evaluation of the dose. The importance of water phantom in the radiosurgery system was also shown. (K.H.)

  3. PyEEG: an open source Python module for EEG/MEG feature extraction.

    Science.gov (United States)

    Bao, Forrest Sheng; Liu, Xin; Zhang, Christina

    2011-01-01

    Computer-aided diagnosis of neural diseases from EEG signals (or other physiological signals that can be treated as time series, e.g., MEG) is an emerging field that has gained much attention in past years. Extracting features is a key component in the analysis of EEG signals. In our previous works, we have implemented many EEG feature extraction functions in the Python programming language. As Python is gaining more ground in scientific computing, an open source Python module for extracting EEG features has the potential to save much time for computational neuroscientists. In this paper, we introduce PyEEG, an open source Python module for EEG feature extraction.

  4. Remote handling demonstration of ITER blanket module replacement

    International Nuclear Information System (INIS)

    Kakudate, S.; Nakahira, M.; Oka, K.; Taguchi, K.; Obara, K.; Tada, E.; Shibanuma, K.; Tesini, A.; Haange, R.; Maisonnier, D.

    2001-01-01

    In ITER, the in-vessel components such as blanket are to be maintained or replaced remotely since they will be activated by 14 MeV neutrons, and a complete exchange of shielding blanket with breeding blanket is foreseen after the Basic Performance Phase. The blanket is segmented into about seven hundred modules to facilitate remote maintainability and allow individual module replacement. For this, the remote handing equipment for blanket maintenance is required to handle a module with a dead weight of about 4 tonne within a positioning accuracy of a few mm under intense gamma radiation. According to the ITER R and D program, a rail-mounted vehicle manipulator system was developed and the basic feasibility of this system was verified through prototype testing. Following this, development of full-scale remote handling equipment has been conducted as one of the ITER Seven R and D Projects aiming at a remote handling demonstration of the ITER blanket. As a result, the Blanket Test Platform (BTP) composed of the full-scale remote handling equipment has been completed and the first integrated performance test in March 1998 has shown that the fabricate remote handling equipment satisfies the main requirements of ITER blanket maintenance. (author)

  5. Receiver bandwidth effects on complex modulation and detection using directly modulated lasers.

    Science.gov (United States)

    Yuan, Feng; Che, Di; Shieh, William

    2016-05-01

    Directly modulated lasers (DMLs) have long been employed for short- and medium-reach optical communications due to their low cost. Recently, a new modulation scheme called complex modulated DMLs has been demonstrated showing a significant optical signal to noise ratio sensitivity enhancement compared with the traditional intensity-only detection scheme. However, chirp-induced optical spectrum broadening is inevitable in complex modulated systems, which may imply a need for high-bandwidth receivers. In this Letter, we study the impact of receiver bandwidth effects on the performance of complex modulation and coherent detection systems based on DMLs. We experimentally demonstrate that such systems exhibit a reasonable tolerance for the reduced receiver bandwidth. For 10 Gbaud 4-level pulse amplitude modulation signals, the required electrical bandwidth is as low as 8.5 and 7.5 GHz for 7% and 20% forward error correction, respectively. Therefore, it is feasible to realize DML-based complex modulated systems using cost-effective receivers with narrow bandwidth.

  6. Bent Electro-Absorption Modulator

    DEFF Research Database (Denmark)

    2002-01-01

    by applying a variable electric or electronmagnetic field. The modulation of the complex refractive index results in a modulation of the refractive index contrast and the absorption coefficient for the waveguide at the frequency of the light. By carefully adjusting the composition of the semiconducting...... components and the applied electric field in relation to the frequency of the modulated radiation, the bending losses (and possibly coupling losses) will provide extinction of light guided by the bent waveguide section. The refractive index contract may be modulated while keeping the absorption coefficient......The present invention relates to a method and a device for modulating optical signals based on modulating bending losses in bend, quantum well semiconductor waveguide sections. The complex refractive index of the optical active semiconducting components of the waveguide section is modulated...

  7. High throughput diffractive multi-beam femtosecond laser processing using a spatial light modulator

    Energy Technology Data Exchange (ETDEWEB)

    Kuang Zheng [Laser Group, Department of Engineering, University of Liverpool Brownlow Street, Liverpool L69 3GQ (United Kingdom)], E-mail: z.kuang@liv.ac.uk; Perrie, Walter [Laser Group, Department of Engineering, University of Liverpool Brownlow Street, Liverpool L69 3GQ (United Kingdom); Leach, Jonathan [Department of Physics and Astronomy, University of Glasgow, Glasgow G12 8QQ (United Kingdom); Sharp, Martin; Edwardson, Stuart P. [Laser Group, Department of Engineering, University of Liverpool Brownlow Street, Liverpool L69 3GQ (United Kingdom); Padgett, Miles [Department of Physics and Astronomy, University of Glasgow, Glasgow G12 8QQ (United Kingdom); Dearden, Geoff; Watkins, Ken G. [Laser Group, Department of Engineering, University of Liverpool Brownlow Street, Liverpool L69 3GQ (United Kingdom)

    2008-12-30

    High throughput femtosecond laser processing is demonstrated by creating multiple beams using a spatial light modulator (SLM). The diffractive multi-beam patterns are modulated in real time by computer generated holograms (CGHs), which can be calculated by appropriate algorithms. An interactive LabVIEW program is adopted to generate the relevant CGHs. Optical efficiency at this stage is shown to be {approx}50% into first order beams and real time processing has been carried out at 50 Hz refresh rate. Results obtained demonstrate high precision surface micro-structuring on silicon and Ti6Al4V with throughput gain >1 order of magnitude.

  8. Verification of the Gaspar dose assessment module used in Maxigasp and Popgasp

    International Nuclear Information System (INIS)

    Hamby, D.M.

    1992-01-01

    The GASPAR module utilized in MAXIGASP and POPGASP has been verified by hand calculations. The program operates as documented by the NRC [Eckerman et. al. 1980]. Equations used in the code to calculate downwind deposition rates, concentrations in air, on ground surfaces, and in vegetables, meat, and milk are provided in this report

  9. Verification of the Gaspar dose assessment module used in Maxigasp and Popgasp

    Energy Technology Data Exchange (ETDEWEB)

    Hamby, D.M.

    1992-12-31

    The GASPAR module utilized in MAXIGASP and POPGASP has been verified by hand calculations. The program operates as documented by the NRC [Eckerman et. al. 1980]. Equations used in the code to calculate downwind deposition rates, concentrations in air, on ground surfaces, and in vegetables, meat, and milk are provided in this report.

  10. Modulational effects in accelerators

    International Nuclear Information System (INIS)

    Satogata, T.

    1997-01-01

    We discuss effects of field modulations in accelerators, specifically those that can be used for operational beam diagnostics and beam halo control. In transverse beam dynamics, combined effects of nonlinear resonances and tune modulations influence diffusion rates with applied tune modulation has been demonstrated. In the longitudinal domain, applied RF phase and voltage modulations provide mechanisms for parasitic halo transport, useful in slow crystal extraction. Experimental experiences with transverse tune and RF modulations are also discussed

  11. Lives Saved Tool (LiST) costing: a module to examine costs and prioritize interventions.

    Science.gov (United States)

    Bollinger, Lori A; Sanders, Rachel; Winfrey, William; Adesina, Adebiyi

    2017-11-07

    Achieving the Sustainable Development Goals will require careful allocation of resources in order to achieve the highest impact. The Lives Saved Tool (LiST) has been used widely to calculate the impact of maternal, neonatal and child health (MNCH) interventions for program planning and multi-country estimation in several Lancet Series commissions. As use of the LiST model increases, many have expressed a desire to cost interventions within the model, in order to support budgeting and prioritization of interventions by countries. A limited LiST costing module was introduced several years ago, but with gaps in cost types. Updates to inputs have now been added to make the module fully functional for a range of uses. This paper builds on previous work that developed an initial version of the LiST costing module to provide costs for MNCH interventions using an ingredients-based costing approach. Here, we update in 2016 the previous econometric estimates from 2013 with newly-available data and also include above-facility level costs such as program management. The updated econometric estimates inform percentages of intervention-level costs for some direct costs and indirect costs. These estimates add to existing values for direct cost requirements for items such as drugs and supplies and required provider time which were already available in LiST Costing. Results generated by the LiST costing module include costs for each intervention, as well as disaggregated costs by intervention including drug and supply costs, labor costs, other recurrent costs, capital costs, and above-service delivery costs. These results can be combined with mortality estimates to support prioritization of interventions by countries. The LiST costing module provides an option for countries to identify resource requirements for scaling up a maternal, neonatal, and child health program, and to examine the financial impact of different resource allocation strategies. It can be a useful tool for

  12. Lives Saved Tool (LiST costing: a module to examine costs and prioritize interventions

    Directory of Open Access Journals (Sweden)

    Lori A. Bollinger

    2017-11-01

    Full Text Available Abstract Background Achieving the Sustainable Development Goals will require careful allocation of resources in order to achieve the highest impact. The Lives Saved Tool (LiST has been used widely to calculate the impact of maternal, neonatal and child health (MNCH interventions for program planning and multi-country estimation in several Lancet Series commissions. As use of the LiST model increases, many have expressed a desire to cost interventions within the model, in order to support budgeting and prioritization of interventions by countries. A limited LiST costing module was introduced several years ago, but with gaps in cost types. Updates to inputs have now been added to make the module fully functional for a range of uses. Methods This paper builds on previous work that developed an initial version of the LiST costing module to provide costs for MNCH interventions using an ingredients-based costing approach. Here, we update in 2016 the previous econometric estimates from 2013 with newly-available data and also include above-facility level costs such as program management. The updated econometric estimates inform percentages of intervention-level costs for some direct costs and indirect costs. These estimates add to existing values for direct cost requirements for items such as drugs and supplies and required provider time which were already available in LiST Costing. Results Results generated by the LiST costing module include costs for each intervention, as well as disaggregated costs by intervention including drug and supply costs, labor costs, other recurrent costs, capital costs, and above-service delivery costs. These results can be combined with mortality estimates to support prioritization of interventions by countries. Conclusions The LiST costing module provides an option for countries to identify resource requirements for scaling up a maternal, neonatal, and child health program, and to examine the financial impact of different

  13. Design of the individual Marx modules for the Atlas machine 36 megajoule, 25 megampere capacitor bank

    International Nuclear Information System (INIS)

    Reass, W.A.; Bowman, D.W.; Gribble, R.F.; Griego, J.R.; Thompson, C.; Parsons, W.M.

    1995-01-01

    This paper presents the preliminary electrical and mechanical design of the Atlas machine's 1.8 megajoule, 600 kV Marx modules. The modules are implemented with plastic cased capacitors similar to those developed for the Defense Nuclear Agency (DNA) ACE II and ACE IV machines. The double ended electrode capacitor style has been dubbed ''FASTCAP.'' Electrodes are provided for mounting rail-gaps on one side and flat plate transmission line damping resistors on the other. This provides for an extremely low circuit inductance. A series array of ten capacitors, each rated at 60 kV, 33.5 uF, and 60 kJ, with their five triggered rail-gaps, form a Marx submodule. Three Marx submodules are nested into a large G-10 fiberglass rack to form a complete Marx module. The module support rack has individual capacitor shelves that ease assembly and replacement. The Marx's design also facilitates construction, testing and verification of a modules performance prior to installation. Modules will be repaired or maintained in a separate test bay without affecting machine operation schedules. Railgap maintenance will become part of a regularly-scheduled preventative maintenance program as spare modules are installed and removed from the machine

  14. Meteorological Instrumentation and Measurements Open Resource Training Modules for Undergraduate and Graduate Education

    Science.gov (United States)

    Rockwell, A.; Clark, R. D.; Stevermer, A.

    2017-12-01

    The National Center for Atmospheric Research Earth Observing Laboratory, Millersville University and The COMET Program are collaborating to produce a series of nine online modules on the the topic of meteorological instrumentation and measurements. These interactive, multimedia educational modules can be integrated into undergraduate and graduate meteorology courses on instrumentation, measurement science, and observing systems to supplement traditional pedagogies and enhance blended instruction. These freely available and open-source training tools are designed to supplement traditional pedagogies and enhance blended instruction. Three of the modules are now available and address the theory and application of Instrument Performance Characteristics, Meteorological Temperature Instrumentation and Measurements, and Meteorological Pressure Instrumentation and Measurements. The content of these modules is of the highest caliber as it has been developed by scientists and engineers who are at the forefront of the field of observational science. Communicating the availability of these unique and influential educational resources with the community is of high priority. These modules will have a profound effect on the atmospheric observational sciences community by fulfilling a need for contemporary, interactive, multimedia guided education and training modules integrating the latest instructional design and assessment tools in observational science. Thousands of undergraduate and graduate students will benefit, while course instructors will value a set of high quality modules to use as supplements to their courses. The modules can serve as an alternative to observational research training and fill the void between field projects or assist those schools that lack the resources to stage a field- or laboratory-based instrumentation experience.

  15. Experimental program at the LOTUS facility

    International Nuclear Information System (INIS)

    Azam, S.; Haldy, P.A.; Kumar, A.; Leo, W.R.; Sahraoui, C.; Schneeberger, J.P.; Tsang, F.; Green, L.

    1986-01-01

    The objectives of the LOTUS experimental program are to study, from a neutronics point of view, blanket modules having features representative of conceptual fusion reactor blanket designs. Such small-scale generic experiments should help to eliminate possible blind alleys, and thus save much time and money later when commercial-size devices will be constructed. At present, two different types of blanket designs are being studied at the LOTUS facility. The first one represents a hybrid fission-suppressed blanket developed at IGA. It is a parallelepiped-shaped assembly, with a fissile breeding zone made of aluminum-clad thorium oxide rods, and a tritium breeding zone simulated by lithium carbonate compressed powder in aluminum boxes. The second blanket that is currently being tested at IGA is the Lithium Blanket Module (LBM) developed by PPPL under the sponsorship of the Electric Power Research Institute. Essentially, the same kind of experiments will be carried out in all the blanket modules. Measurement of foil activities as well as tritium production in the blanket are the primary diagnostic means in the current LOTUS experimental program. Preanalyses of the experimental data have been carried out at IGA with the help of the two-dimensional discrete ordinates transport code DOT3.5 coupled to the GRTUNCL first collision routine. For the experiments described above, the agreement between experimental and computed results is generally fair

  16. Latin American Knowledge Networking Program on Gender ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    This project aims to strengthen the capacity of Latin American researchers, academics, policymakers and practitioners to mainstream gender in macroeconomic policies and programs. The project will consist of three elements: a self-study module that introduces participants to gender-aware approaches to macroeconomics ...

  17. Design Program in Graphic User Interface Environment for Automobile ER Devices

    Science.gov (United States)

    Lim, S. C.; Park, J. S.; Sohn, J. W.; Choi, S. B.

    This work presents a design and analysis program for vehicle devices utilizing an electrorheological (ER) fluid. The program is operated in graphic user interface (GUI) environment and the initial window is consisted of four subprogram modules which are related to ER shock absorber, ER seat damper, ER engine mount, and ER anti-lock brake system (ABS), respectively. In order to execute each module, both material properties and design parameters are to be chosen by the user. Then, the output display window shows the field-dependent performance characteristics to be considered as design criteria. In addition, control performances of the vehicle system equipped with ER devices are displayed in time and frequency domain. In order to demonstrate the effectiveness of the proposed program, ER shock absorber and ER ABS are designed and manufactured and their performance characteristics are evaluated.

  18. VPI-NECM, Nuclear Engineering Program Collection for College Training

    International Nuclear Information System (INIS)

    Honomichl, Jiri; Kulikowska, Teresa; Szczesna, Barbara

    1991-01-01

    1 - Description of problem or function: The VPI Modules consist of 6 independent programs designed to calculate: module FARCON - neutron slowing down and epithermal group constants, module SLOCON - thermal neutron spectrum and group constants, module DISFAC - slow neutron disadvantage factors, module ODOG - solution of a one group neutron diffusion equation, module ODMUG - three group critically problem, module FUELBURN - fuel burnup in slow neutron fission reactors. 2 - Method of solution: Module FARCON solves the diffusion equation for a homogeneous medium composed of N isotopes, in 33 groups in fast and resonance energy region. The solution in the thermal energy region carried out by module SLOCON is based on the Wigner-Wilkins approximation and applies the Runge-Kutta method. The burnup calculations are carried out in 3 energy groups. Only Xe-135 and Sm-149 are treated directly. All the other fission products are represented by 2 pseudo isotopes. Module ODOG solves the finite difference diffusion equation by a direct method. Module ODMUG uses the Chebyshev acceleration of outer iterations. It gives a possibility to calculate a critical boron concentration. 3 - Restrictions on the complexity of the problem: It is assumed that the elementary reactor cell consists of the fuel rod surrounded by water. The library data are limited to isotopes typical for water power reactors. The reactor can be treated in one dimension only, i.e. as a slab, sphere or cylinder with one-dimensional symmetry

  19. Comparison of optimization algorithms in intensity-modulated radiation therapy planning

    Science.gov (United States)

    Kendrick, Rachel

    Intensity-modulated radiation therapy is used to better conform the radiation dose to the target, which includes avoiding healthy tissue. Planning programs employ optimization methods to search for the best fluence of each photon beam, and therefore to create the best treatment plan. The Computational Environment for Radiotherapy Research (CERR), a program written in MATLAB, was used to examine some commonly-used algorithms for one 5-beam plan. Algorithms include the genetic algorithm, quadratic programming, pattern search, constrained nonlinear optimization, simulated annealing, the optimization method used in Varian EclipseTM, and some hybrids of these. Quadratic programing, simulated annealing, and a quadratic/simulated annealing hybrid were also separately compared using different prescription doses. The results of each dose-volume histogram as well as the visual dose color wash were used to compare the plans. CERR's built-in quadratic programming provided the best overall plan, but avoidance of the organ-at-risk was rivaled by other programs. Hybrids of quadratic programming with some of these algorithms seems to suggest the possibility of better planning programs, as shown by the improved quadratic/simulated annealing plan when compared to the simulated annealing algorithm alone. Further experimentation will be done to improve cost functions and computational time.

  20. A design of optical modulation system with pixel-level modulation accuracy

    Science.gov (United States)

    Zheng, Shiwei; Qu, Xinghua; Feng, Wei; Liang, Baoqiu

    2018-01-01

    Vision measurement has been widely used in the field of dimensional measurement and surface metrology. However, traditional methods of vision measurement have many limits such as low dynamic range and poor reconfigurability. The optical modulation system before image formation has the advantage of high dynamic range, high accuracy and more flexibility, and the modulation accuracy is the key parameter which determines the accuracy and effectiveness of optical modulation system. In this paper, an optical modulation system with pixel level accuracy is designed and built based on multi-points reflective imaging theory and digital micromirror device (DMD). The system consisted of digital micromirror device, CCD camera and lens. Firstly we achieved accurate pixel-to-pixel correspondence between the DMD mirrors and the CCD pixels by moire fringe and an image processing of sampling and interpolation. Then we built three coordinate systems and calculated the mathematic relationship between the coordinate of digital micro-mirror and CCD pixels using a checkerboard pattern. A verification experiment proves that the correspondence error is less than 0.5 pixel. The results show that the modulation accuracy of system meets the requirements of modulation. Furthermore, the high reflecting edge of a metal circular piece can be detected using the system, which proves the effectiveness of the optical modulation system.