WorldWideScience

Sample records for pterional keyhole clipping

  1. Median Supraorbital Keyhole Approach for Clipping Ruptured Distal Anterior Cerebral Artery Aneurysm: Technical Report with Review of Literature.

    Science.gov (United States)

    Dhandapani, Sivashanmugam; Sahoo, Sushant Kumar

    2018-04-01

    The minimally invasive approach to distal anterior cerebral artery (DACA) aneurysms has not gained much acceptance due to difficulties associated with the conventional frontal paramedian approach. The more proximal basal interhemispheric approach, however, necessitates extensive dissection of soft tissues. We describe a novel minimally invasive median supraorbital keyhole craniotomy with a basal interhemispheric approach for clipping a ruptured DACA aneurysm. A 62-year-old patient presented with subarachnoid hemorrhage. Computed tomography angiography revealed a DACA aneurysm. The surgical technique involved a keyhole craniotomy made via an eyebrow incision extending between the supraorbital notches, and flush with the anterior cranial fossa. The dura was opened at the anterior part, the falx was cut, an interhemispheric dissection was carried out, adequate proximal control was obtained, and the aneurysm neck was dissected and clipped. A relevant review of the literature was carried out. The patient recovered well, with no residual aneurysm or forehead numbness, with good cosmesis. Compared with the previously described "keyhole unilateral interhemispheric" approaches, our technique has less likelihood of encountering bridging veins; easier cisternal cerebrospinal fluid release, making it feasible even in swollen brain; better proximal vascular control; and trajectory toward the neck rather than dome. The median supraorbital keyhole approach is a minimally invasive technique sufficient for clipping most DACA aneurysms, with easier access, better proximal control, and good cosmesis. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Usefulness of the pterion plate in frontotemporal craniotomy

    International Nuclear Information System (INIS)

    Goto, Akiko; Aoki, Yoshinori; Kano, Toshiyuki

    2008-01-01

    The objective of this study was to evaluate the usefulness of the pterion plate in preventing depression of the lateral side of the orbita after frontotemporal craniotomy. Forty patients who underwent frontotemporal craniotomy at our facility were studied: 20 received pterion plates during surgery (pterion plate group) and 20 did not (non-pterion plate group). In all patients, postoperative bone window CT was used to confirm the presence or absence of a depression (≥5 mm) on the lateral side of the orbita. Patient satisfaction was assessed by a questionnaire. Depression of the lateral side of the orbita on postoperative bone window CT was noted in none of the subjects in the pterion plate group and in 12 (60%) of the subjects in the non-pterion plate group (p<0.01). Patient satisfaction was higher in the pterion plate than in the non-pterion plate group (p<0.01). Findings from bone window CT and the questionnaire indicate that the pterion plate is effective in preventing postoperative depression of the lateral side of the orbita during frontotemporal craniotomy. (author)

  3. Clip reconstruction of a large right MCA bifurcation aneurysm. Case report

    Directory of Open Access Journals (Sweden)

    Giovani A.

    2014-06-01

    Full Text Available We report a case of complex large middle cerebral artery (MCA bifurcation aneurysm that ruptured during dissection from the very adherent MCA branches but was successfully clipped and the MCA bifurcation reconstructed using 4 Yasargill clips. Through a right pterional craniotomy the sylvian fissure was largely opened as to allow enough workspace for clipping the aneurysm and placing a temporary clip on M1. The pacient recovered very well after surgery and was discharged after 1 week with no neurological deficit. Complex MCA bifurcation aneurysms can be safely reconstructed using regular clips, without the need of using fenestrated clips or complex by-pass procedures.

  4. Anatomic study of the pterion in Nigerian dry human skulls.

    Science.gov (United States)

    Ukoha, U; Oranusi, C K; Okafor, J I; Udemezue, O O; Anyabolu, A E; Nwamarachi, T C

    2013-01-01

    The pterion is a point of sutural confluence seen in the norma lateralis of the skull. The site is an important landmark in surgical approaches to the anterior and middle cranial fossa. This study was designed to determine the frequency of pterion types and anatomic positions of the pterion in dry human skulls of Nigerians in the South Eastern Zone. Specific measurements were taken on both sides of 56 Nigerian human skulls of unknown sex, obtained from the Department of Anatomy, Nnamdi Azikiwe University, Nnewi Campus, Nnewi, Nigeria. All the four types of the pterion were present, i.e. sphenoparietal, frontotemporal, stellate, and epipteric. The study showed that the sphenoparietal type was 75% on the right side, 76% on the left side, the frontotemporal type was 19.6% on both sides, the stellate type was 1.8% on the right side and absent on the left side. The epipteric type was 3.6% on both sides. The distances from the centre of pterion to the frontozygomatic suture were 2.74 ± 0.07 cm on the right side and 2.74 ± 0.06 cm on the left side. The pterion was 4.02 ± 0.05 and 4.01 ± 0.03 cm above the midpoint of the zygomatic arch on the right and left sides, respectively. These findings are important for the surgeon as the pterion junction is a common extracranial landmark in neurosurgical and surgical approaches.

  5. On the Keyhole Hypothesis

    DEFF Research Database (Denmark)

    Mikkelsen, Kaare B.; Kidmose, Preben; Hansen, Lars Kai

    2017-01-01

    simultaneously recorded scalp EEG. A cross-validation procedure was employed to ensure unbiased estimates. We present several pieces of evidence in support of the keyhole hypothesis: There is a high mutual information between data acquired at scalp electrodes and through the ear-EEG "keyhole," furthermore we......We propose and test the keyhole hypothesis that measurements from low dimensional EEG, such as ear-EEG reflect a broadly distributed set of neural processes. We formulate the keyhole hypothesis in information theoretical terms. The experimental investigation is based on legacy data consisting of 10...

  6. Cosmetic and functional reconstruction achieved using a split myofascial bone flap for pterional craniotomy. Technical note.

    Science.gov (United States)

    Matsumoto, K; Akagi, K; Abekura, M; Ohkawa, M; Tasaki, O; Tomishima, T

    2001-04-01

    Cosmetic deformities that appear following pterional craniotomy are usually caused by temporal muscle atrophy, injury to the frontotemporal branch of the facial nerve, or bone pits in the craniotomy line. To resolve these problems during pterional craniotomy, an alternative method was developed in which a split myofascial bone flap and a free bone flap are used. The authors have used this method in the treatment of 40 patients over the last 3 years. Excellent cosmetic and functional results have been obtained. This method can provide wide exposure similar to that achieved using Yaşargil's interfascial pterional craniotomy, without limiting the operative field with a bulky temporal muscle flap.

  7. Weld pool and keyhole dynamic analysis based on visual system and neural network during laser keyhole welding

    OpenAIRE

    Luo, Masiyang

    2014-01-01

    In keyhole fiber laser welding processes, the weld pool behavior and keyhole dynamics are essential to determining welding quality. To observe and control the welding process, the accurate extraction of the weld pool boundary as well as the width is required. In addition, because of the cause-and-effect relationship between the welding defects and stability of the keyhole, which is primarily determined by keyhole geometry during the welding process, the stability of keyhole needs to be consid...

  8. Post-operative orofacial pain, temporomandibular dysfunction and trigeminal sensitivity after recent pterional craniotomy: preliminary study.

    Science.gov (United States)

    Brazoloto, Thiago Medina; de Siqueira, Silvia Regina Dowgan Tesseroli; Rocha-Filho, Pedro Augusto Sampaio; Figueiredo, Eberval Gadelha; Teixeira, Manoel Jacobsen; de Siqueira, José Tadeu Tesseroli

    2017-05-01

    Surgical trauma at the temporalis muscle is a potential cause of post-craniotomy headache and temporomandibular disorders (TMD). The aim of this study was to evaluate the prevalence of pain, masticatory dysfunction and trigeminal somatosensory abnormalities in patients who acquired aneurysms following pterional craniotomy. Fifteen patients were evaluated before and after the surgical procedure by a trained dentist. The evaluation consisted of the (1) research diagnostic criteria for TMD, (2) a standardized orofacial pain questionnaire and (3) a systematic protocol for quantitative sensory testing (QST) for the trigeminal nerve. After pterional craniotomy, 80% of the subjects, 12 patients, developed orofacial pain triggered by mandibular function. The pain intensity was measured by using the visual analog scale (VAS), and the mean pain intensity was 3.7. The prevalence of masticatory dysfunction was 86.7%, and there was a significant reduction of the maximum mouth opening. The sensory evaluation showed tactile and thermal hypoesthesia in the area of pterional access in all patients. There was a high frequency of temporomandibular dysfunction, postoperative orofacial pain and trigeminal sensory abnormalities. These findings can help to understand several abnormalities that can contribute to postoperative headache or orofacial pain complaints after pterional surgeries.

  9. Keyhole shapes during laser welding of thin metal sheets

    International Nuclear Information System (INIS)

    Aalderink, B J; Lange, D F de; Aarts, R G K M; Meijer, J

    2007-01-01

    Camera observations of the full penetration keyhole laser welding process show that the keyhole shape is elongated under certain welding conditions. Under these unfavourable circumstances, the welding process is susceptible to holes in the weld bead. Existing models of the pressure balance at the keyhole wall cannot explain this keyhole elongation. In this paper a new model is presented, accounting for the doubly curved shape of the keyhole wall. In this model, the surface tension pressure has one term that tends to close the keyhole and another term that tries to open it. Model calculations show that when the keyhole diameter is of the same order as the sheet thickness, the latter part can become dominant, causing the keyhole to elongate. Experiments on thin aluminium (AA5182) and mild steel (DC04) sheets verify these model calculations. As the keyhole radius depends on the radius of the focused laser spot, it was found for both materials that the ratio of the spot radius and the sheet thickness must be above a critical value to prevent keyhole elongation. These critical radii are 0.25 for AA5182 and 0.4 for DC04, respectively. Furthermore, differences in appearance of the weld bead between the circular and the elongated keyhole welds could be explained by this model

  10. Keyhole behaviour during laser welding of zinc-coated steel

    International Nuclear Information System (INIS)

    Pan, Y; Richardson, I M

    2011-01-01

    The production of consistent, high-quality laser welds on zinc-coated steels for the automotive industry remains a challenge. A simple overlap joint geometry is desirable in these applications but has been shown to be extremely detrimental to laser welding because the zinc vapour formed at the interface between the two sheets expands into the keyhole and disrupts fluid flow in the melt pool, which often leads to metal ejection. In this work, laser welding on sheets with various coating thicknesses has been performed and it is observed that the sheets with thick coatings (∼20 μm) show surprisingly good weldability. High speed video camera visualizations of the keyhole provide insight into the keyhole dynamics during the process. It appears that the dynamic pressure of zinc vapour can effectively elongate the keyhole and the process can reach a stable state when an elongated keyhole is continuously present. A simple analytical model has been developed to describe the influence of zinc vapour on keyhole elongation.

  11. Status analysis of keyhole bottom in laser-MAG hybrid welding process.

    Science.gov (United States)

    Wang, Lin; Gao, Xiangdong; Chen, Ziqin

    2018-01-08

    The keyhole status is a determining factor of weld quality in laser-metal active gas arc (MAG) hybrid welding process. For a better evaluation of the hybrid welding process, three different penetration welding experiments: partial penetration, normal penetration (or full penetration), and excessive penetration were conducted in this work. The instantaneous visual phenomena including metallic vapor, spatters and keyhole of bottom surface were used to evaluate the keyhole status by a double high-speed camera system. The Fourier transform was applied on the bottom weld pool image for removing the image noise around the keyhole, and then the bottom weld pool image was reconstructed through the inverse Fourier transform. Lastly, the keyhole bottom was extracted from the de-noised bottom weld pool image. By analyzing the visual features of the laser-MAG hybrid welding process, mechanism of the closed and opened keyhole bottom were revealed. The results show that the stable opened or closed status of keyhole bottom is directly affected by the MAG droplet transition in the normal penetration welding process, and the unstable opened or closed status of keyhole bottom would appear in excessive penetration welding and partial penetration welding. The analysis method proposed in this paper could be used to monitor the keyhole stability in laser-MAG hybrid welding process.

  12. Visualizing the influence of the process parameters on the keyhole dimensions in plasma arc welding

    International Nuclear Information System (INIS)

    Liu, Z M; Wu, C S; Chen, M A

    2012-01-01

    The keyhole status and its dimensions are critical information determining both the process quality and weld quality in plasma arc welding (PAW). It is of great significance to measure the keyhole shape and size and to correlate them with the main process parameters. In this study, a low-cost vision system is developed to visualize the keyhole at the backside of the test-pieces in PAW. Three stages of keyhole evolution, i.e. initial blind stage (non-penetrated keyhole), unstable stage with momentarily disappeared keyhole and quasi-steady open keyhole stage (fully-penetrated keyhole), are measured in real-time during the PAW tests on stainless steel test-pieces of thickness 8 mm. Based on the captured images of keyhole under different welding conditions, the correlations of the main welding process parameters (welding current, welding speed, plasma gas flow rate) with the keyhole length, width and area are visualized through vision measurement. It lays a solid foundation for implementing keyhole stability control and process optimization in keyhole PAW. (paper)

  13. Vapor plume oscillation mechanisms in transient keyhole during tandem dual beam fiber laser welding

    Science.gov (United States)

    Chen, Xin; Zhang, Xiaosi; Pang, Shengyong; Hu, Renzhi; Xiao, Jianzhong

    2018-01-01

    Vapor plume oscillations are common physical phenomena that have an important influence on the welding process in dual beam laser welding. However, until now, the oscillation mechanisms of vapor plumes remain unclear. This is primarily because mesoscale vapor plume dynamics inside a millimeter-scale, invisible, and time-dependent keyhole are difficult to quantitatively observe. In this paper, based on a developed three-dimensional (3D) comprehensive model, the vapor plume evolutions in a dynamical keyhole are directly simulated in tandem dual beam, short-wavelength laser welding. Combined with the vapor plume behaviors outside the keyhole observed by high-speed imaging, the vapor plume oscillations in dynamical keyholes at different inter-beam distances are the first, to our knowledge, to be quantitatively analyzed. It is found that vapor plume oscillations outside the keyhole mainly result from vapor plume instabilities inside the keyhole. The ejection velocity at the keyhole opening and dynamical behaviors outside the keyhole of a vapor plume both violently oscillate with the same order of magnitude of high frequency (several kHz). Furthermore, the ejection speed at the keyhole opening and ejection area outside the keyhole both decrease as the beam distance increases, while the degree of vapor plume instability first decreases and then increases with increasing beam distance from 0.6 to 1.0 mm. Moreover, the oscillation mechanisms of a vapor plume inside the dynamical keyhole irradiated by dual laser beams are investigated by thoroughly analyzing the vapor plume occurrence and flow process. The vapor plume oscillations in the dynamical keyhole are found to mainly result from violent local evaporations and severe keyhole geometry variations. In short, the quantitative method and these findings can serve as a reference for further understanding of the physical mechanisms in dual beam laser welding and of processing optimizations in industrial applications.

  14. Multiple reflections and Fresnel absorption in an actual 3D keyhole during deep penetration laser welding

    Energy Technology Data Exchange (ETDEWEB)

    Jin Xiangzhong [Laser Institute of Hunan University, Changsha, Hunan, 410082 (China); Berger, Peter [Institut fuer Strahlwerkzeuge (IFSW), University of Stuttgart, Pfaffenwaldring 43, 70569 Stuttgart (Germany); Graf, Thomas [Institut fuer Strahlwerkzeuge (IFSW), University of Stuttgart, Pfaffenwaldring 43, 70569 Stuttgart (Germany)

    2006-11-07

    In laser welding experiments of glass, keyhole shapes are observed by two high-speed cameras from two perpendicular directions. From the obtained keyhole pictures, it can be seen that in medium- and low-speed laser penetration welding, the main distortion of the keyhole is not the section metamorphosis from rotational symmetry, but the bending of its centre line. Based on such a keyhole photograph, the keyhole profiles and its centre line are determined by the method of polynomial fitting. Then, under the assumption of a circular cross section at each depth of the keyhole, the behaviour of the laser beam in the keyhole is analysed by tracing a ray of light using geometrical optics theory; the Fresnel absorption and multiple reflections in the keyhole are systematically studied, and the laser intensities absorbed on the keyhole walls are calculated. The absorbed laser intensity is not distributed uniformly on the keyhole wall. The keyhole wall absorbs laser intensity mainly on the half-part of the keyhole wall near the front wall. Because of the high absorptivity of the glass, Fresnel absorption from the first incidence of a laser beam plays a dominant role in the final laser intensity distribution on the keyhole wall, multiple reflections have some minor effects on the intensity distribution on the bottom part of the keyhole.

  15. One Piece Orbitozygomatic Approach Based on the Sphenoid Ridge Keyhole

    DEFF Research Database (Denmark)

    Spiriev, Toma; Poulsgaard, Lars; Fugleholm, Kåre

    2016-01-01

    The one-piece orbitozygomatic (OZ) approach is traditionally based on the McCarty keyhole. Here, we present the use of the sphenoid ridge keyhole and its possible advantages as a keyhole for the one-piece OZ approach. Using transillumination technique the osteology of the sphenoid ridge...... was examined on 20 anatomical dry skull specimens. The results were applied to one-piece OZ approaches performed on freshly frozen cadaver heads. We defined the center of the sphenoid ridge keyhole as a superficial projection on the lateral skull surface of the most anterior and thickest part of the sphenoid...... ridge. It was located 22 mm (standard deviation [SD], 0.22 mm) from the superior temporal line; 10.7 mm (SD, 0.08 mm) posterior and 7.1 mm (SD, 0.22 mm) inferior to the frontozygomatic suture. The sphenoid ridge burr hole provides exposure of frontal, temporal dura as well as periorbita, which...

  16. Advances in open microsurgery for cerebral aneurysms.

    Science.gov (United States)

    Davies, Jason M; Lawton, Michael T

    2014-02-01

    Endovascular techniques introduced strong extrinsic forces that provoked reactive changes in aneurysm surgery. Microsurgery has become less invasive, more appealing to patients, lower risk, and efficacious for complex aneurysms, particularly those unfavorable for or failing endovascular therapy. To review specific advances in open microsurgery for aneurysms. A university-based, single-surgeon practice was examined for the use of minimally invasive craniotomies, surgical management of recurrence after coiling, the use of intracranial-intracranial bypass techniques, and cerebrovascular volume-outcome relationships. The mini-pterional, lateral supraorbital, and orbital-pterional craniotomies are minimally invasive alternatives to standard craniotomies. Mini-pterional and lateral supraorbital craniotomies were used in one-fourth of unruptured patients, increasing from 22% to 28%, whereas 15% of patients underwent orbital-pterional craniotomies and trended upward from 11% to 20%. Seventy-four patients were treated for coil recurrences (2.3% of all aneurysms) with direct clip occlusion (77%), clip occlusion after coil extraction (7%), or parent artery occlusion with bypass (16%). Intracranial-intracranial bypass (in situ bypass, reimplantation, reanastomosis, and intracranial grafts) transformed the management of giant aneurysms and made the surgical treatment of posterior inferior cerebellar artery aneurysms competitive with endovascular therapy. Centralization maximized the volume-outcome relationships observed with clipping. Aneurysm microsurgery has embraced minimalism, tailoring the exposure to the patient's anatomy with the smallest possible craniotomy that provides adequate exposure. The development of intracranial-intracranial bypasses is an important advancement that makes microsurgery a competitive option for complex and recurrent aneurysms. Trends toward centralizing aneurysm surgery in tertiary centers optimize results achievable with open microsurgery.

  17. Numerical modeling of keyhole dynamics in laser welding

    Science.gov (United States)

    Zhang, Wen-Hai; Zhou, Jun; Tsai, Hai-Lung

    2003-03-01

    Mathematical models and the associated numerical techniques have been developed to study the following cases: (1) the formation and collapse of a keyhole, (2) the formation of porosity and its control strategies, (3) laser welding with filler metals, and (4) the escape of zinc vapor in laser welding of galvanized steel. The simulation results show that the formation of porosity in the weld is caused by two competing mechanisms: one is the solidification rate of the molten metal and the other is the speed that molten metal backfills the keyhole after laser energy is terminated. The models have demonstrated that porosity can be reduced or eliminated by adding filler metals, controlling laser tailing power, or applying an electromagnetic force during keyhole collapse process. It is found that a uniform composition of weld pool is difficult to achieve by filler metals due to very rapid solidification of the weld pool in laser welding, as compared to that in gas metal arc welding.

  18. WE-G-18C-08: Real Time Tumor Imaging Using a Novel Dynamic Keyhole MRI Reconstruction Technique

    International Nuclear Information System (INIS)

    Lee, D; Pollock, S; Whelan, B; Keall, P; Greer, P; Kim, T

    2014-01-01

    Purpose: To test the hypothesis that the novel Dynamic Keyhole MRI reconstruction technique can accelerate image acquisition whilst maintaining high image quality for lung cancer patients. Methods: 18 MRI datasets from 5 lung cancer patients were acquired using a 3T MRI scanner. These datasets were retrospectively reconstructed using (A) The novel Dynamic Keyhole technique, (B) The conventional keyhole technique and (C) the conventional zero filling technique. The dynamic keyhole technique in MRI refers to techniques in which previously acquired k-space data is used to supplement under sampled data obtained in real time. The novel Dynamic Keyhole technique utilizes a previously acquired a library of kspace datasets in conjunction with central k-space datasets acquired in realtime. A simultaneously acquired respiratory signal is utilized to sort, match and combine the two k-space streams with respect to respiratory displacement. Reconstruction performance was quantified by (1) comparing the keyhole size (which corresponds to imaging speed) required to achieve the same image quality, and (2) maintaining a constant keyhole size across the three reconstruction methods to compare the resulting image quality to the ground truth image. Results: (1) The dynamic keyhole method required a mean keyhole size which was 48% smaller than the conventional keyhole technique and 60% smaller than the zero filling technique to achieve the same image quality. This directly corresponds to faster imaging. (2) When a constant keyhole size was utilized, the Dynamic Keyhole technique resulted in the smallest difference of the tumor region compared to the ground truth. Conclusion: The dynamic keyhole is a simple and adaptable technique for clinical applications requiring real-time imaging and tumor monitoring such as MRI guided radiotherapy. Based on the results from this study, the dynamic keyhole method could increase the imaging frequency by a factor of five compared with full k

  19. The keyhole GTAW technology: a new welding technology joining quality and productivity

    International Nuclear Information System (INIS)

    Le Port, P.; Laugier, M.; Scandella, F.; Lawrjaniec, D.; Boucher, Ch.

    2006-01-01

    This paper is a literature review regarding the keyhole GTAW technology, which has been developed and first used for industrial applications in Australia. The process enables single pass welding of a wide range of materials including stainless steels, titanium and nickel alloys, up to 12 mm thick. Process parameters (welding current, arc voltage, travel speed, the type of shielding gas and tungsten electrode dimensions) are discussed with regards to keyhole formation and stability. A comparison between standard GTAW and keyhole GTAW is provided for the welding of 12 mm thick stainless steel and titanium, showing the substantial increase in productivity that can be achieved with this new technology. Institut de Soudure has taken part in a European project aimed at assessing the possibilities of the keyhole GTAW technology. (authors)

  20. A three-dimensional sharp interface model for self-consistent keyhole and weld pool dynamics in deep penetration laser welding

    International Nuclear Information System (INIS)

    Pang Shengyong; Chen Liliang; Zhou Jianxin; Yin Yajun; Chen Tao

    2011-01-01

    A three-dimensional sharp interface model is proposed to investigate the self-consistent keyhole and weld pool dynamics in deep penetration laser welding. The coupling of three-dimensional heat transfer, fluid flow and keyhole free surface evolutions in the welding process is simulated. It is theoretically confirmed that under certain low heat input welding conditions deep penetration laser welding with a collapsing free keyhole could be obtained and the flow directions near the keyhole wall are upwards and approximately parallel to the keyhole wall. However, significantly different weld pool dynamics in a welding process with an unstable keyhole are numerically found. Many flow patterns in the welding process with an unstable keyhole, verified by x-ray transmission experiments, were successfully simulated and analysed. Periodical keyhole collapsing and bubble formation processes are also successfully simulated and believed to be in good agreement with experiments. The mechanisms of keyhole instability are found to be closely associated with the behaviour of humps on the keyhole wall, and it is found that the welding speed and surface tension are closely related to the formation of humps on the keyhole wall. It is also shown that the weld pool dynamics in laser welding with an unstable keyhole are closely associated with the transient keyhole instability and therefore modelling keyhole and weld pool in a self-consistent way is significant to understand the physics of laser welding.

  1. Scaling of spiking and humping in keyhole welding

    Energy Technology Data Exchange (ETDEWEB)

    Wei, P S; Chuang, K C [Department of Mechanical and Electro-Mechanical Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan (China); DebRoy, T [Department of Materials Science and Engineering, The Pennsylvania State University, University Park, PA 16802 (United States); Ku, J S, E-mail: pswei@mail.nsysu.edu.tw, E-mail: cielo.zhuang@gmail.com, E-mail: rtd1@psu.edu, E-mail: jsku@mail.nsysu.edu.tw [Institute of Materials Science and Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan (China)

    2011-06-22

    Spiking, rippling and humping seriously reduce the strength of welds. The effects of beam focusing, volatile alloying element concentration and welding velocity on spiking, coarse rippling and humping in keyhole mode electron-beam welding are examined through scale analysis. Although these defects have been studied in the past, the mechanisms for their formation are not fully understood. This work relates the average amplitudes of spikes to fusion zone depth for the welding of Al 6061, SS 304 and carbon steel, and Al 5083. The scale analysis introduces welding and melting efficiencies and an appropriate power distribution to account for the focusing effects, and the energy which is reflected and escapes through the keyhole opening to the surroundings. The frequency of humping and spiking can also be predicted from the scale analysis. The analysis also reveals the interrelation between coarse rippling and humping. The data and the mechanistic findings reported in this study are useful for understanding and preventing spiking and humping during keyhole mode electron and laser beam welding.

  2. Multiple Reflections and Fresnel Absorption of Gaussian Laser Beam in an Actual 3D Keyhole during Deep-Penetration Laser Welding

    Directory of Open Access Journals (Sweden)

    Xiangzhong Jin

    2012-01-01

    Full Text Available In deep penetration laser welding, a keyhole is formed in the material. Based on an experimentally obtained bending keyhole from low- and medium-speed laser penetration welding of glass, the keyhole profiles in both the symmetric plane are determined by polynomial fitting. Then, a 3D bending keyhole is reconstructed under the assumption of circular cross-section of the keyhole at each keyhole depth. In this paper, the behavior of focused Gaussian laser beam in the keyhole is analyzed by tracing a ray of light using Gaussian optics theory, the Fresnel absorption and multiple reflections in the keyhole are systematically studied, and the laser intensities absorbed on the keyhole walls are calculated. Finally, the formation mechanism of the keyhole is deduced.

  3. Microsurgical clipping for the true posterior communicating artery aneurysm in the distal portion of the posterior communicating artery.

    Science.gov (United States)

    Takeda, Masaru; Kashimura, Hiroshi; Chida, Kohei; Murakami, Toshiyuki

    2015-01-01

    Aneurysms arising from the posterior communicating artery (PCoA) itself are rare in which aneurysms usually located in the proximal portion of the PCoA. The authors report a case of the true PCoA ruptured aneurysm in the distal portion of the PCoA. The patient was an 83-year-old man who suffered subarachnoid hemorrhage. Cerebral angiography revealed a saccular aneurysm arising on the fetal type right PCoA itself in the distal portion of the PCoA. 2 days after the onset of symptoms, the patient underwent right interfascial pterional craniotomy, with anterior temporal approach. The aneurysm was successfully clipped with the preservation of both the PCoA and the thalamoperforating artery. We speculated that blood flow into the PCoA gradually increased after occlusion of the left vertebral artery, which induced tortuosity of the PCoA. As a result, hemodynamic stress might increase near the curvature and cause aneurysm formation.

  4. Implementation of real-time multiple reflection and Fresnel absorption of laser beam in keyhole

    International Nuclear Information System (INIS)

    Cho, Jung-Ho; Na, Suck-Joo

    2006-01-01

    A computational analysis of laser keyhole welding is achieved. The main driving force to make the molten pool as a narrow and deep keyhole is the recoil pressure induced by evaporation of the material. Also, the multiple reflection effect on the keyhole wall plays an important role in making the keyhole deeper and raising its total energy absorption rate. Multiple reflection and Fresnel absorption are implemented simultaneously with the proposed ray tracing technique in a discrete grid cell system during the simulation for every single time step. In particular, the Fresnel absorption model is chosen as an energy transfer mechanism from laser beam to workpiece. With all the governing equations including continuity, momentum and energy equation, the VOF method is adopted to trace the free surface of the molten pool. Simulation results are compared with the experimental ones to verify its validity. A pulsed Nd : YAG laser was used for keyhole welding experiments on mild steel plates of 7 mm thickness. It was observed that the generated keyhole maintains its solidified shape without any closing phenomenon both in the experiments and in the simulations

  5. Implementation of real-time multiple reflection and Fresnel absorption of laser beam in keyhole

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jung-Ho; Na, Suck-Joo [Department of Mechanical Engineering, KAIST, 373-1 Guseong-dong, Yuseong-gu, Daejeon 305-701 (Korea, Republic of)

    2006-12-21

    A computational analysis of laser keyhole welding is achieved. The main driving force to make the molten pool as a narrow and deep keyhole is the recoil pressure induced by evaporation of the material. Also, the multiple reflection effect on the keyhole wall plays an important role in making the keyhole deeper and raising its total energy absorption rate. Multiple reflection and Fresnel absorption are implemented simultaneously with the proposed ray tracing technique in a discrete grid cell system during the simulation for every single time step. In particular, the Fresnel absorption model is chosen as an energy transfer mechanism from laser beam to workpiece. With all the governing equations including continuity, momentum and energy equation, the VOF method is adopted to trace the free surface of the molten pool. Simulation results are compared with the experimental ones to verify its validity. A pulsed Nd : YAG laser was used for keyhole welding experiments on mild steel plates of 7 mm thickness. It was observed that the generated keyhole maintains its solidified shape without any closing phenomenon both in the experiments and in the simulations.

  6. Post-Vacuum-Assisted Stereotactic Core Biopsy Clip Displacement: A Comparison Between Commercially Available Clips and Surgical Clip.

    Science.gov (United States)

    Yen, Peggy; Dumas, Sandra; Albert, Arianne; Gordon, Paula

    2018-02-01

    The placement of localization clips following percutaneous biopsy is a standard practice for a variety of situations. Subsequent clip displacement creates challenges for imaging surveillance and surgical planning, and may cause confusion amongst radiologists and between surgeons and radiologists. Many causes have been attributed for this phenomenon including the commonly accepted "accordion effect." Herein, we investigate the performance of a low cost surgical clip system against 4 commercially available clips. We retrospectively reviewed 2112 patients who underwent stereotactic vacuum-assisted core biopsy followed by clip placement between January 2013 and June 2016. The primary performance parameter compared was displacement >10 mm following vacuum-assisted stereotactic core biopsy. Within the group of clips that had displaced, the magnitude of displacement was compared. There was a significant difference in displacement among the clip types (P < .0001) with significant pairwise comparisons between pediatric surgical clips and SecureMark (38% vs 28%; P = .001) and SenoMark (38% vs 27%; P = .0001) in the proportion displaced. The surgical clips showed a significant magnitude of displacement of approximately 25% greater average distance displaced. As a whole, the commercial clips performed better than the surgical clip after stereotactic vacuum-assisted core biopsy suggesting the surrounding outer component acts to anchor the central clip and minimizes clip displacement. The same should apply to tomosynthesis-guided biopsy. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  7. Supraorbital keyhole surgery for optic nerve decompression and dura repair.

    Science.gov (United States)

    Chen, Yuan-Hao; Lin, Shinn-Zong; Chiang, Yung-Hsiao; Ju, Da-Tong; Liu, Ming-Ying; Chen, Guann-Juh

    2004-07-01

    Supraorbital keyhole surgery is a limited surgical procedure with reduced traumatic manipulation of tissue and entailing little time in the opening and closing of wounds. We utilized the approach to treat head injury patients complicated with optic nerve compression and cerebrospinal fluid leakage (CSF). Eleven cases of basal skull fracture complicated with either optic nerve compression and/or CSF leakage were surgically treated at our department from February 1995 to June 1999. Six cases had primary optic nerve compression, four had CSF leakage and one case involved both injuries. Supraorbital craniotomy was carried out using a keyhole-sized burr hole plus a small craniotomy. The size of craniotomy approximated 2 x 3 cm2. The optic nerve was decompressed via removal of the optic canal roof and anterior clinoid process with high-speed drills. The defect of dura was repaired with two pieces of tensa fascia lata that were attached on both sides of the torn dural defect with tissue glue. Seven cases with optic nerve injury included five cases of total blindness and two cases of light perception before operation. Vision improved in four cases. The CSF leakage was stopped successfully in all four cases without complication. As optic nerve compression and CSF leakage are skull base lesions, the supraorbital keyhole surgery constitutes a suitable approach. The supraorbital keyhole surgery allows for an anterior approach to the skull base. This approach also allows the treatment of both CSF leakage and optic nerve compression. Our results indicate that supraorbital keyhole operation is a safe and effective method for preserving or improving vision and attenuating CSF leakage following injury.

  8. Selective amygdalohippocampectomy via trans-superior temporal gyrus keyhole approach.

    Science.gov (United States)

    Mathon, Bertrand; Clemenceau, Stéphane

    2016-04-01

    Hippocampal sclerosis is the most common cause of drug-resistant epilepsy amenable for surgical treatment and seizure control. The rationale of the selective amygdalohippocampectomy is to spare cerebral tissue not included in the seizure generator. Describe the selective amygdalohippocampectomy through the trans-superior temporal gyrus keyhole approach. Selective amygdalohippocampectomy for temporal lobe epilepsy is performed when the data (semiology, neuroimaging, electroencephalography) point to the mesial temporal structures. The trans-superior temporal gyrus keyhole approach is a minimally invasive and safe technique that allows disconnection of the temporal stem and resection of temporomesial structures.

  9. An Argument for the Keyhole Template for Close Air Support on the Urban Battlefield

    Science.gov (United States)

    2009-03-04

    An Argument for the Keyhole Template for Close Air Support on the Urban Battlefield Captain BT Taggart Major RC... Keyhole Template for Close Air Support on the Urban Battlefield 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT...graphic (GRG). Using the target building as the keyhole , or center of the engagement area, Lightning 62 requested a laser guided Maverick to destroy

  10. da Vinci robot-assisted keyhole neurosurgery: a cadaver study on feasibility and safety.

    Science.gov (United States)

    Marcus, Hani J; Hughes-Hallett, Archie; Cundy, Thomas P; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar

    2015-04-01

    The goal of this cadaver study was to evaluate the feasibility and safety of da Vinci robot-assisted keyhole neurosurgery. Several keyhole craniotomies were fashioned including supraorbital subfrontal, retrosigmoid and supracerebellar infratentorial. In each case, a simple durotomy was performed, and the flap was retracted. The da Vinci surgical system was then used to perform arachnoid dissection towards the deep-seated intracranial cisterns. It was not possible to simultaneously pass the 12-mm endoscope and instruments through the keyhole craniotomy in any of the approaches performed, limiting visualization. The articulated instruments provided greater dexterity than existing tools, but the instrument arms could not be placed in parallel through the keyhole craniotomy and, therefore, could not be advanced to the deep cisterns without significant clashing. The da Vinci console offered considerable ergonomic advantages over the existing operating room arrangement, allowing the operating surgeon to remain non-sterile and seated comfortably throughout the procedure. However, the lack of haptic feedback was a notable limitation. In conclusion, while robotic platforms have the potential to greatly enhance the performance of transcranial approaches, there is strong justification for research into next-generation robots, better suited to keyhole neurosurgery.

  11. Effect of keyhole characteristics on porosity formation during pulsed laser-GTA hybrid welding of AZ31B magnesium alloy

    Science.gov (United States)

    Chen, Minghua; Xu, Jiannan; Xin, Lijun; Zhao, Zuofu; Wu, Fufa; Ma, Shengnan; Zhang, Yue

    2017-06-01

    This paper experimentally investigates the relationship between laser keyhole characteristics on the porosity formation during pulsed laser-GTA welding of magnesium alloy. Based on direct observations during welding process, the influences of laser keyhole state on the porosity formation were studied. Results show that the porosities in the joint are always at the bottom of fusion zone of the joint, which is closely related to the keyhole behavior. A large depth to wide ratio always leads to the increase of porosity generation chance. Keeping the keyhole outlet open for a longer time benefits the porosity restriction. Overlap of adjacent laser keyhole can effectively decrease the porosity generation, due to the cutting effect between adjacent laser keyholes. There are threshold overlap rate values for laser keyholes in different state.

  12. Keyhole imaging method for dynamic objects behind the occlusion area

    Science.gov (United States)

    Hao, Conghui; Chen, Xi; Dong, Liquan; Zhao, Yuejin; Liu, Ming; Kong, Lingqin; Hui, Mei; Liu, Xiaohua; Wu, Hong

    2018-01-01

    A method of keyhole imaging based on camera array is realized to obtain the video image behind a keyhole in shielded space at a relatively long distance. We get the multi-angle video images by using a 2×2 CCD camera array to take the images behind the keyhole in four directions. The multi-angle video images are saved in the form of frame sequences. This paper presents a method of video frame alignment. In order to remove the non-target area outside the aperture, we use the canny operator and morphological method to realize the edge detection of images and fill the images. The image stitching of four images is accomplished on the basis of the image stitching algorithm of two images. In the image stitching algorithm of two images, the SIFT method is adopted to accomplish the initial matching of images, and then the RANSAC algorithm is applied to eliminate the wrong matching points and to obtain a homography matrix. A method of optimizing transformation matrix is proposed in this paper. Finally, the video image with larger field of view behind the keyhole can be synthesized with image frame sequence in which every single frame is stitched. The results show that the screen of the video is clear and natural, the brightness transition is smooth. There is no obvious artificial stitching marks in the video, and it can be applied in different engineering environment .

  13. Experimental research on the dynamic behaviors of the keyhole and molten pool in laser deep-penetration welding

    Science.gov (United States)

    Zhang, Yi; Lin, Qida; Yin, Xuni; Li, Simeng; Deng, Jiquan

    2018-04-01

    Both the morphology and temperature are two important characteristics of the keyhole and the molten pool in laser deep-penetration welding. The modified ‘sandwich’ method was adopted to overcome the difficulty in obtaining inner information about the keyhole and the molten pool. Based on this method, experimental platforms were built for observing the variations in the surface morphology, the longitudinal keyhole profile and the internal temperature. The experimental results of three dynamic behaviors exbibit as follows. The key factor, which makes the pool width go into a quasi-steady state, lies in the balance between the vortex and the sideways flows around the keyhole. Experimental observation shows that the keyhole goes through three stages in laser welding: the rapid drilling stage, the slow drilling stage and the quasi-steady state. The time for achieving a relative fixed keyhole depth is close to the formation time of the maximum pool width. The internal temperatures inside the keyhole and the molten pool first experience a rapid increase, then a decrease and finally go into a quasi-steady state. Compared to that in the unstable stage, the liquid–metal uphill formed in the stable stage of laser welding has less influence on the internal temperature.

  14. A Technique for Resecting Occipital Pole Gliomas Using a Keyhole Lobectomy.

    Science.gov (United States)

    Conner, Andrew K; Baker, Cordell M; Briggs, Robert G; Burks, Joshua D; Glenn, Chad A; Smitherman, Adam D; Morgan, Jake P; Pittman, Nathan A; Sughrue, Michael E

    2017-10-01

    Our purpose is to describe a method of resecting occipital pole gliomas through a keyhole lobectomy and share the patient outcomes of this technique. We performed a retrospective review of data obtained on all patients who underwent resection of occipital pole gliomas by the senior author between 2012 and 2016. We describe our technique for resecting these tumors using a keyhole lobectomy and share the patient outcomes of this operation. Eight patients were included in this study. Four patients (50%) had not received previous surgery. One patient (13%) was diagnosed with a World Health Organization grade II tumor, and 7 patients (88%) were diagnosed with glioblastoma. Two tumors (25%) were left sided and 6 (75%) right sided. The median size of resection was 28 cm 3 . The median extent of resection was 96%, and at least 90% of the tumor was resected in all cases. None of the patients experienced permanent postoperative complications. Temporary neurologic complications included 3 patients (38%) with encephalopathy and 1 patient (13%) with aphasia. There were no neurosurgical complications. Our study provides details on the technical aspects of occipital keyhole lobectomies and gives the outcomes of patients who have received an operation for tumors in this uncommon location. Taking white matter tract anatomy into consideration, we show that the keyhole method can be applied to gliomas of the occipital lobe. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Dynamics of vapor plume in transient keyhole during laser welding of stainless steel: Local evaporation, plume swing and gas entrapment into porosity

    Science.gov (United States)

    Pang, Shengyong; Chen, Xin; Shao, Xinyu; Gong, Shuili; Xiao, Jianzhong

    2016-07-01

    In order to better understand the local evaporation phenomena of keyhole wall, vapor plume swing above the keyhole and ambient gas entrapment into the porosity defects, the 3D time-dependent dynamics of the metallic vapor plume in a transient keyhole during fiber laser welding is numerically investigated. The vapor dynamical parameters, including the velocity and pressure, are successfully predicted and obtain good agreements with the experimental and literature data. It is found that the vapor plume flow inside the keyhole has complex multiple directions, and this various directions characteristic of the vapor plume is resulted from the dynamic evaporation phenomena with variable locations and orientations on the keyhole wall. The results also demonstrate that because of this dynamic local evaporation, the ejected vapor plume from the keyhole opening is usually in high frequency swinging. The results further indicate that the oscillation frequency of the plume swing angle is around 2.0-8.0 kHz, which is of the same order of magnitude with that of the keyhole depth (2.0-5.0 kHz). This consistency clearly shows that the swing of the ejected vapor plume is closely associated with the keyhole instability during laser welding. Furthermore, it is learned that there is usually a negative pressure region (several hundred Pa lower than the atmospheric pressure) of the vapor flow around the keyhole opening. This pressure could lead to a strong vortex flow near the rear keyhole wall, especially when the velocity of the ejected metallic vapor from the keyhole opening is high. Under the effect of this flow, the ambient gas is involved into the keyhole, and could finally be entrapped into the bubbles within a very short time (keyhole.

  16. On the Keyhole Hypothesis: High Mutual Information between Ear and Scalp EEG

    Directory of Open Access Journals (Sweden)

    Kaare B. Mikkelsen

    2017-06-01

    Full Text Available We propose and test the keyhole hypothesis—that measurements from low dimensional EEG, such as ear-EEG reflect a broadly distributed set of neural processes. We formulate the keyhole hypothesis in information theoretical terms. The experimental investigation is based on legacy data consisting of 10 subjects exposed to a battery of stimuli, including alpha-attenuation, auditory onset, and mismatch-negativity responses and a new medium-long EEG experiment involving data acquisition during 13 h. Linear models were estimated to lower bound the scalp-to-ear capacity, i.e., predicting ear-EEG data from simultaneously recorded scalp EEG. A cross-validation procedure was employed to ensure unbiased estimates. We present several pieces of evidence in support of the keyhole hypothesis: There is a high mutual information between data acquired at scalp electrodes and through the ear-EEG “keyhole,” furthermore we show that the view—represented as a linear mapping—is stable across both time and mental states. Specifically, we find that ear-EEG data can be predicted reliably from scalp EEG. We also address the reverse view, and demonstrate that large portions of the scalp EEG can be predicted from ear-EEG, with the highest predictability achieved in the temporal regions and when using ear-EEG electrodes with a common reference electrode.

  17. Improving Keyhole Stability by External Magnetic Field in Full Penetration Laser Welding

    Science.gov (United States)

    Li, Min; Xu, Jiajun; Huang, Yu; Rong, Youmin

    2018-05-01

    An external magnetic field was used to improve the keyhole stability in full penetration laser welding 316L steel. The increase of magnetic field strength gave rise to a shorter flying time of the spatter, a weaker size and brightness of the spatter, and a larger spreading area of vapor plume. This suggested that the dynamic behavior of the keyhole was stabilized by the external magnetic field. In addition, a stronger magnetic field could result in a more homogeneous distribution of laser energy, which increased the width of the weld zone, and the height of the bottom weld zone from 381 μm (0 mT) to 605 μm (50 mT). Dendrite and cellular crystal near the weld center disappeared, and grain size was refined. The external magnetic field was beneficial to the keyhole stability and improved the joint quality, because the weld pool was stirred by a Lorentz force resulting from the coupling effect of the magnetic field and inner thermocurrent.

  18. Quantifying the accuracy of the tumor motion and area as a function of acceleration factor for the simulation of the dynamic keyhole magnetic resonance imaging method

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Danny; Pollock, Sean; Keall, Paul, E-mail: paul.keall@sydney.edu.au [Radiation Physics Laboratory, Sydney Medical School, University of Sydney, Sydney, NSW 2006 (Australia); Greer, Peter B. [School of Mathematical and Physical Sciences, University of Newcastle, Newcastle, NSW 2308, Australia and Department of Radiation Oncology, Calvary Mater Newcastle Hospital, Newcastle, NSW 2298 (Australia); Kim, Taeho [Radiation Physics Laboratory, Sydney Medical School, University of Sydney, Sydney, NSW 2006, Australia and Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23219 (United States)

    2016-05-15

    Purpose: The dynamic keyhole is a new MR image reconstruction method for thoracic and abdominal MR imaging. To date, this method has not been investigated with cancer patient magnetic resonance imaging (MRI) data. The goal of this study was to assess the dynamic keyhole method for the task of lung tumor localization using cine-MR images reconstructed in the presence of respiratory motion. Methods: The dynamic keyhole method utilizes a previously acquired a library of peripheral k-space datasets at similar displacement and phase (where phase is simply used to determine whether the breathing is inhale to exhale or exhale to inhale) respiratory bins in conjunction with central k-space datasets (keyhole) acquired. External respiratory signals drive the process of sorting, matching, and combining the two k-space streams for each respiratory bin, thereby achieving faster image acquisition without substantial motion artifacts. This study was the first that investigates the impact of k-space undersampling on lung tumor motion and area assessment across clinically available techniques (zero-filling and conventional keyhole). In this study, the dynamic keyhole, conventional keyhole and zero-filling methods were compared to full k-space dataset acquisition by quantifying (1) the keyhole size required for central k-space datasets for constant image quality across sixty four cine-MRI datasets from nine lung cancer patients, (2) the intensity difference between the original and reconstructed images in a constant keyhole size, and (3) the accuracy of tumor motion and area directly measured by tumor autocontouring. Results: For constant image quality, the dynamic keyhole method, conventional keyhole, and zero-filling methods required 22%, 34%, and 49% of the keyhole size (P < 0.0001), respectively, compared to the full k-space image acquisition method. Compared to the conventional keyhole and zero-filling reconstructed images with the keyhole size utilized in the dynamic keyhole

  19. Cranio-orbital approach for complex aneurysmal surgery.

    LENUS (Irish Health Repository)

    Kelleher, M O

    2012-02-03

    Certain aneurysms of the anterior circulation continue to offer a technical challenge for safe exposure and clipping. The purpose of this paper was to describe the cranio-orbital approach for surgical clipping of complex aneurysms and to evaluate prospectively the associated complications of this approach. Prospective audit of all patients undergoing cranio-orbital approach for aneurysm surgery from 1997 to 2004 by the senior author. Twenty-five patients, eight male and 17 female, median age of 52 years, range 28-73. All patients had a standard pterional approach supplemented by an orbital osteotomy. In the 7-year period 367 patients underwent treatment for their aneurysms (169 clipped and 198 coiled). Of the 169 patients who were operated on, 29 had a skull base approach, of which 25 were cranio-orbital. The aneurysm location was as follows: 16 middle cerebral artery (MCA), three carotid bifurcation, four anterior communicating artery (ACOMM), one ophthalmic and one basilar. There were no approach-related complications. The cranio-orbital craniotomy can be a useful adjunct in the surgical treatment of giant or complex aneurysms. It offers the following advantages over a standard pterional approach: reduces operative distance; allows easy splitting of the sylvian fissure; and provides a wide arc of exposure with multiple working corridors.

  20. Quantifying the accuracy of the tumor motion and area as a function of acceleration factor for the simulation of the dynamic keyhole magnetic resonance imaging method.

    Science.gov (United States)

    Lee, Danny; Greer, Peter B; Pollock, Sean; Kim, Taeho; Keall, Paul

    2016-05-01

    The dynamic keyhole is a new MR image reconstruction method for thoracic and abdominal MR imaging. To date, this method has not been investigated with cancer patient magnetic resonance imaging (MRI) data. The goal of this study was to assess the dynamic keyhole method for the task of lung tumor localization using cine-MR images reconstructed in the presence of respiratory motion. The dynamic keyhole method utilizes a previously acquired a library of peripheral k-space datasets at similar displacement and phase (where phase is simply used to determine whether the breathing is inhale to exhale or exhale to inhale) respiratory bins in conjunction with central k-space datasets (keyhole) acquired. External respiratory signals drive the process of sorting, matching, and combining the two k-space streams for each respiratory bin, thereby achieving faster image acquisition without substantial motion artifacts. This study was the first that investigates the impact of k-space undersampling on lung tumor motion and area assessment across clinically available techniques (zero-filling and conventional keyhole). In this study, the dynamic keyhole, conventional keyhole and zero-filling methods were compared to full k-space dataset acquisition by quantifying (1) the keyhole size required for central k-space datasets for constant image quality across sixty four cine-MRI datasets from nine lung cancer patients, (2) the intensity difference between the original and reconstructed images in a constant keyhole size, and (3) the accuracy of tumor motion and area directly measured by tumor autocontouring. For constant image quality, the dynamic keyhole method, conventional keyhole, and zero-filling methods required 22%, 34%, and 49% of the keyhole size (P lung tumor monitoring applications. This study demonstrates that the dynamic keyhole method is a promising technique for clinical applications such as image-guided radiation therapy requiring the MR monitoring of thoracic tumors. Based

  1. Fuzzy expert systems using CLIPS

    Science.gov (United States)

    Le, Thach C.

    1994-01-01

    This paper describes a CLIPS-based fuzzy expert system development environment called FCLIPS and illustrates its application to the simulated cart-pole balancing problem. FCLIPS is a straightforward extension of CLIPS without any alteration to the CLIPS internal structures. It makes use of the object-oriented and module features in CLIPS version 6.0 for the implementation of fuzzy logic concepts. Systems of varying degrees of mixed Boolean and fuzzy rules can be implemented in CLIPS. Design and implementation issues of FCLIPS will also be discussed.

  2. Seismic signals hard clipping overcoming

    Science.gov (United States)

    Olszowa, Paula; Sokolowski, Jakub

    2018-01-01

    In signal processing the clipping is understand as the phenomenon of limiting the signal beyond certain threshold. It is often related to overloading of a sensor. Two particular types of clipping are being recognized: soft and hard. Beyond the limiting value soft clipping reduces the signal real gain while the hard clipping stiffly sets the signal values at the limit. In both cases certain amount of signal information is lost. Obviously if one possess the model which describes the considered signal and the threshold value (which might be slightly more difficult to obtain in the soft clipping case), the attempt of restoring the signal can be made. Commonly it is assumed that the seismic signals take form of an impulse response of some specific system. This may lead to belief that the sine wave may be the most appropriate to fit in the clipping period. However, this should be tested. In this paper the possibility of overcoming the hard clipping in seismic signals originating from a geoseismic station belonging to an underground mine is considered. A set of raw signals will be hard-clipped manually and then couple different functions will be fitted and compared in terms of least squares. The results will be then analysed.

  3. Concept of the central clip

    DEFF Research Database (Denmark)

    Alegria-Barrero, Eduardo; Chan, Pak Hei; Foin, Nicolas

    2014-01-01

    AIMS: Percutaneous edge-to-edge mitral valve repair with the MitraClip(®) was shown to be a safe and feasible alternative compared to conventional surgical mitral valve repair. We analyse the concept of the central clip and the predictors for the need of more than one MitraClip(®) in our high.......8±10.7 years (30 males, 13 females; mean logistic EuroSCORE 24.1±11, mean LVEF 47.5±18.5%; mean±SD) were treated. Median follow-up was 385 days (104-630; Q1-Q3). Device implantation success was 93%. All patients were treated following the central clip concept: 52.5% of MR was degenerative in aetiology and 47....... The presence of a restricted posterior mitral valve leaflet (PML) was inversely correlated with the need for more than one clip (p=0.02). A cut-off value of ≥7.5 mm for vena contracta predicted the need for a second clip (sensitivity 83%, specificity 90%, p=0.01). CONCLUSIONS: The central MitraClip(®) concept...

  4. Keyhole formation and thermal fluid flow-induced porosity during laser fusion welding in titanium alloys: Experimental and modelling

    International Nuclear Information System (INIS)

    Panwisawas, Chinnapat; Perumal, Bama; Ward, R. Mark; Turner, Nathanael; Turner, Richard P.; Brooks, Jeffery W.; Basoalto, Hector C.

    2017-01-01

    High energy-density beam welding, such as electron beam or laser welding, has found a number of industrial applications for clean, high-integrity welds. The deeply penetrating nature of the joints is enabled by the formation of metal vapour which creates a narrow fusion zone known as a “keyhole”. However the formation of the keyhole and the associated keyhole dynamics, when using a moving laser heat source, requires further research as they are not fully understood. Porosity, which is one of a number of process induced phenomena related to the thermal fluid dynamics, can form during beam welding processes. The presence of porosity within a welded structure, inherited from the fusion welding operation, degrades the mechanical properties of components during service such as fatigue life. In this study, a physics-based model for keyhole welding including heat transfer, fluid flow and interfacial interactions has been used to simulate keyhole and porosity formation during laser welding of Ti-6Al-4V titanium alloy. The modelling suggests that keyhole formation and the time taken to achieve keyhole penetration can be predicted, and it is important to consider the thermal fluid flow at the melting front as this dictates the evolution of the fusion zone. Processing induced porosity is significant when the fusion zone is only partially penetrating through the thickness of the material. The modelling results are compared with high speed camera imaging and measurements of porosity from welded samples using X-ray computed tomography, radiography and optical micrographs. These are used to provide a better understanding of the relationship between process parameters, component microstructure and weld integrity.

  5. Postoperative subdural hygroma and chronic subdural hematoma after unruptured aneurysm surgery: age, sex, and aneurysm location as independent risk factors.

    Science.gov (United States)

    Park, Jaechan; Cho, Jae-Hoon; Goh, Duck-Ho; Kang, Dong-Hun; Shin, Im Hee; Hamm, In-Suk

    2016-02-01

    This study investigated the incidence and risk factors for the postoperative occurrence of subdural complications, such as a subdural hygroma and resultant chronic subdural hematoma (CSDH), following surgical clipping of an unruptured aneurysm. The critical age affecting such occurrences and follow-up results were also examined. The case series included 364 consecutive patients who underwent aneurysm clipping via a pterional or superciliary keyhole approach for an unruptured saccular aneurysm in the anterior cerebral circulation between 2007 and 2013. The subdural hygromas were identified based on CT scans 6-9 weeks after surgery, and the volumes were measured using volumetry studies. Until their complete resolution, all the subdural hygromas were followed using CT scans every 1-2 months. Meanwhile, the CSDHs were classified as nonoperative or operative lesions that were treated by bur-hole drainage. The age and sex of the patients, aneurysm location, history of a subarachnoid hemorrhage (SAH), and surgical approach (pterional vs superciliary) were all analyzed regarding the postoperative occurrence of a subdural hygroma or CSDH. The follow-up results of the subdural complications were also investigated. Seventy patients (19.2%) developed a subdural hygroma or CSDH. The results of a multivariate analysis showed that advanced age (p = 0.003), male sex (p 60 years, which achieved a 70% sensitivity and 69% specificity with regard to predicting such subdural complications. The female patients ≤ 60 years of age showed a negligible incidence of subdural complications for all aneurysm groups, whereas the male patients > 60 years of age showed the highest incidence of subdural complications at 50%-100%, according to the aneurysm location. The subdural hygromas detected 6-9 weeks postoperatively showed different follow-up results, according to the severity. The subdural hygromas that converted to a CSDH were larger in volume than the subdural hygromas that resolved

  6. Vertical diplopia and oscillopsia due to midbrain keyhole aqueduct syndrome associated with severe cough

    Directory of Open Access Journals (Sweden)

    Angela Jinsook Oh

    2018-06-01

    Full Text Available Purpose: Midline structural defects in the neural axis can give rise to neuro-ophthalmic symptoms. We report a rare case of keyhole aqueduct syndrome presenting after two years of severe cough due to gastroesophageal reflux disease. Observations: A 58-year-old woman with a 2-year history of daily, severe cough presented to the neuro-ophthalmology clinic with progressive diplopia and oscillopsia. Examination revealed a 1–2 Hz down-beating nystagmus in primary gaze that worsened with left, right, and down gazes. Gaze evoked nystagmus and mild paresis were also seen with up gaze. There was an incomitant left hypertropia due to skew deviation that worsened with right and up gazes and improved with down gaze. She also had a right-sided ptosis and a 3 mm anisocoria not due to cranial nerve 3 paresis or Horner's syndrome. Brain magnetic resonance imaging showed a 1.5 mm × 11.7 mm × 6 mm midline cleft in the ventral midbrain communicating with the cerebral aqueduct, consistent with keyhole aqueduct syndrome. Her nystagmus and diplopia improved with oral acetazolamide treatment, at high doses of 2500–3000 mg per day. Conclusions and importance: We report the first case of midbrain keyhole aqueduct syndrome with ocular motor and other neuro-ophthalmic manifestations associated with severe cough. Although her cough was effectively treated and intracranial pressure measurement was normal, her ophthalmic symptoms continued to progress, which is common in previous cases reported. Treatment with acetazolamide led to significant improvement, supporting the use of acetazolamide in this rare condition. Keywords: Keyhole aqueduct syndrome, Midbrain cleft, Mesencephalic cleft, Syrinx, Syringobulbia, Down-beating nystagmus, Cerebrospinal fluid

  7. Selective amygdalohippocampectomy via trans-superior temporal gyrus keyhole approach

    OpenAIRE

    Mathon , Bertrand; Clemenceau , Stéphane

    2016-01-01

    International audience; BackgroundHippocampal sclerosis is the most common cause of drug-resistant epilepsy amenable for surgical treatment and seizure control. The rationale of the selective amygdalohippocampectomy is to spare cerebral tissue not included in the seizure generator.MethodDescribe the selective amygdalohippocampectomy through the trans-superior temporal gyrus keyhole approach.ConclusionSelective amygdalohippocampectomy for temporal lobe epilepsy is performed when the data (semi...

  8. Mounting clips for panel installation

    Science.gov (United States)

    Cavieres, Andres; Al-Haddad, Tristan; Goodman, Joseph; Valdes, Francisco

    2017-02-14

    An exemplary mounting clip for removably attaching panels to a supporting structure comprises a base, spring locking clips, a lateral flange, a lever flange, and a spring bonding pad. The spring locking clips extend upwardly from the base. The lateral flange extends upwardly from a first side of the base. The lateral flange comprises a slot having an opening configured to receive at least a portion of one of the one or more panels. The lever flange extends outwardly from the lateral flange. The spring bonding flange extends downwardly from the lever flange. At least a portion of the first spring bonding flange comprises a serrated edge for gouging at least a portion of the one or more panels when the one or more panels are attached to the mounting clip to electrically and mechanically couple the one or more panels to the mounting clip.

  9. A defect in the CLIP1 gene (CLIP-170) can cause autosomal recessive intellectual disability.

    Science.gov (United States)

    Larti, Farzaneh; Kahrizi, Kimia; Musante, Luciana; Hu, Hao; Papari, Elahe; Fattahi, Zohreh; Bazazzadegan, Niloofar; Liu, Zhe; Banan, Mehdi; Garshasbi, Masoud; Wienker, Thomas F; Ropers, H Hilger; Galjart, Niels; Najmabadi, Hossein

    2015-03-01

    In the context of a comprehensive research project, investigating novel autosomal recessive intellectual disability (ARID) genes, linkage analysis based on autozygosity mapping helped identify an intellectual disability locus on Chr.12q24, in an Iranian family (LOD score = 3.7). Next-generation sequencing (NGS) following exon enrichment in this novel interval, detected a nonsense mutation (p.Q1010*) in the CLIP1 gene. CLIP1 encodes a member of microtubule (MT) plus-end tracking proteins, which specifically associates with the ends of growing MTs. These proteins regulate MT dynamic behavior and are important for MT-mediated transport over the length of axons and dendrites. As such, CLIP1 may have a role in neuronal development. We studied lymphoblastoid and skin fibroblast cell lines established from healthy and affected patients. RT-PCR and western blot analyses showed the absence of CLIP1 transcript and protein in lymphoblastoid cells derived from affected patients. Furthermore, immunofluorescence analyses showed MT plus-end staining only in fibroblasts containing the wild-type (and not the mutant) CLIP1 protein. Collectively, our data suggest that defects in CLIP1 may lead to ARID.

  10. Using the trans-lamina terminalis route via a pterional approach to resect a retrochiasmatic craniopharyngioma involving the third ventricle.

    Science.gov (United States)

    Weil, Alexander G; Robert, Thomas; Alsaiari, Sultan; Obaid, Sami; Bojanowski, Michel W

    2016-01-01

    Retrochiasmatic craniopharyngiomas involving the anterior third ventricle are challenging to access. Although the pterional approach is a common route for suprasellar lesions, when the craniopharyngioma extends behind the chiasma into the third ventricle, access is even more difficult, and the lamina terminalis may offer a good working window. The translamina terminalis approach provides direct access to the retrochiasmatic portion of the tumor with minimal brain retraction and no manipulation of the visual nerves. In this video, we emphasize the utility of using the lamina terminalis corridor to resect the retrochiasmatic intraventricular portion of a craniopharyngioma. The video can be found here: https://youtu.be/hrLNC0hDKe4 .

  11. Authoring Data-Driven Videos with DataClips.

    Science.gov (United States)

    Amini, Fereshteh; Riche, Nathalie Henry; Lee, Bongshin; Monroy-Hernandez, Andres; Irani, Pourang

    2017-01-01

    Data videos, or short data-driven motion graphics, are an increasingly popular medium for storytelling. However, creating data videos is difficult as it involves pulling together a unique combination of skills. We introduce DataClips, an authoring tool aimed at lowering the barriers to crafting data videos. DataClips allows non-experts to assemble data-driven "clips" together to form longer sequences. We constructed the library of data clips by analyzing the composition of over 70 data videos produced by reputable sources such as The New York Times and The Guardian. We demonstrate that DataClips can reproduce over 90% of our data videos corpus. We also report on a qualitative study comparing the authoring process and outcome achieved by (1) non-experts using DataClips, and (2) experts using Adobe Illustrator and After Effects to create data-driven clips. Results indicated that non-experts are able to learn and use DataClips with a short training period. In the span of one hour, they were able to produce more videos than experts using a professional editing tool, and their clips were rated similarly by an independent audience.

  12. Preserving Sharp Edges with Volume Clipping

    NARCIS (Netherlands)

    Termeer, M.A.; Oliván Bescós, J.; Telea, A.C.

    2006-01-01

    Volume clipping is a useful aid for exploring volumetric datasets. To maximize the effectiveness of this technique, the clipping geometry should be flexibly specified and the resulting images should not contain artifacts due to the clipping techniques. We present an improvement to an existing

  13. 21 CFR 882.4215 - Clip rack.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clip rack. 882.4215 Section 882.4215 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4215 Clip rack. (a) Identification. A clip rack is a...

  14. Piezosurgery in Modified Pterional Orbital Decompression Surgery in Graves Disease.

    Science.gov (United States)

    Grauvogel, Juergen; Scheiwe, Christian; Masalha, Waseem; Jarc, Nadja; Grauvogel, Tanja; Beringer, Andreas

    2017-10-01

    Piezosurgery uses microvibrations to selectively cut bone, preserving the adjacent soft tissue. The present study evaluated the use of piezosurgery for bone removal in orbital decompression surgery in Graves disease via a modified pterional approach. A piezosurgical device (Piezosurgery medical) was used in 14 patients (20 orbits) with Graves disease who underwent orbital decompression surgery in additional to drills and rongeurs for bone removal of the lateral orbital wall and orbital roof. The practicability, benefits, and drawbacks of this technique in orbital decompression surgery were recorded. Piezosurgery was evaluated with respect to safety, preciseness of bone cutting, and preservation of the adjacent dura and periorbita. Preoperative and postoperative clinical outcome data were assessed. The orbital decompression surgery was successful in all 20 orbits, with good clinical outcomes and no postoperative complications. Piezosurgery proved to be a safe tool, allowing selective bone cutting with no damage to the surrounding soft tissue structures. However, there were disadvantages concerning the intraoperative handling in the narrow space and the efficiency of bone removal was limited in the orbital decompression surgery compared with drills. Piezosurgery proved to be a useful tool in bone removal for orbital decompression in Graves disease. It is safe and easy to perform, without any danger of damage to adjacent tissue because of its selective bone-cutting properties. Nonetheless, further development of the device is necessary to overcome the disadvantages in intraoperative handling and the reduced bone removal rate. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Intelligent tutoring using HyperCLIPS

    Science.gov (United States)

    Hill, Randall W., Jr.; Pickering, Brad

    1990-01-01

    HyperCard is a popular hypertext-like system used for building user interfaces to databases and other applications, and CLIPS is a highly portable government-owned expert system shell. We developed HyperCLIPS in order to fill a gap in the U.S. Army's computer-based instruction tool set; it was conceived as a development environment for building adaptive practical exercises for subject-matter problem-solving, though it is not limited to this approach to tutoring. Once HyperCLIPS was developed, we set out to implement a practical exercise prototype using HyperCLIPS in order to demonstrate the following concepts: learning can be facilitated by doing; student performance evaluation can be done in real-time; and the problems in a practical exercise can be adapted to the individual student's knowledge.

  16. Content-based video retrieval by example video clip

    Science.gov (United States)

    Dimitrova, Nevenka; Abdel-Mottaleb, Mohamed

    1997-01-01

    This paper presents a novel approach for video retrieval from a large archive of MPEG or Motion JPEG compressed video clips. We introduce a retrieval algorithm that takes a video clip as a query and searches the database for clips with similar contents. Video clips are characterized by a sequence of representative frame signatures, which are constructed from DC coefficients and motion information (`DC+M' signatures). The similarity between two video clips is determined by using their respective signatures. This method facilitates retrieval of clips for the purpose of video editing, broadcast news retrieval, or copyright violation detection.

  17. Cortical Response Similarities Predict which Audiovisual Clips Individuals Viewed, but Are Unrelated to Clip Preference.

    Directory of Open Access Journals (Sweden)

    David A Bridwell

    Full Text Available Cortical responses to complex natural stimuli can be isolated by examining the relationship between neural measures obtained while multiple individuals view the same stimuli. These inter-subject correlation's (ISC's emerge from similarities in individual's cortical response to the shared audiovisual inputs, which may be related to their emergent cognitive and perceptual experience. Within the present study, our goal is to examine the utility of using ISC's for predicting which audiovisual clips individuals viewed, and to examine the relationship between neural responses to natural stimuli and subjective reports. The ability to predict which clips individuals viewed depends on the relationship of the EEG response across subjects and the nature in which this information is aggregated. We conceived of three approaches for aggregating responses, i.e. three assignment algorithms, which we evaluated in Experiment 1A. The aggregate correlations algorithm generated the highest assignment accuracy (70.83% chance = 33.33% and was selected as the assignment algorithm for the larger sample of individuals and clips within Experiment 1B. The overall assignment accuracy was 33.46% within Experiment 1B (chance = 06.25%, with accuracies ranging from 52.9% (Silver Linings Playbook to 11.75% (Seinfeld within individual clips. ISC's were significantly greater than zero for 15 out of 16 clips, and fluctuations within the delta frequency band (i.e. 0-4 Hz primarily contributed to response similarities across subjects. Interestingly, there was insufficient evidence to indicate that individuals with greater similarities in clip preference demonstrate greater similarities in cortical responses, suggesting a lack of association between ISC and clip preference. Overall these results demonstrate the utility of using ISC's for prediction, and further characterize the relationship between ISC magnitudes and subjective reports.

  18. Cortical Response Similarities Predict which Audiovisual Clips Individuals Viewed, but Are Unrelated to Clip Preference.

    Science.gov (United States)

    Bridwell, David A; Roth, Cullen; Gupta, Cota Navin; Calhoun, Vince D

    2015-01-01

    Cortical responses to complex natural stimuli can be isolated by examining the relationship between neural measures obtained while multiple individuals view the same stimuli. These inter-subject correlation's (ISC's) emerge from similarities in individual's cortical response to the shared audiovisual inputs, which may be related to their emergent cognitive and perceptual experience. Within the present study, our goal is to examine the utility of using ISC's for predicting which audiovisual clips individuals viewed, and to examine the relationship between neural responses to natural stimuli and subjective reports. The ability to predict which clips individuals viewed depends on the relationship of the EEG response across subjects and the nature in which this information is aggregated. We conceived of three approaches for aggregating responses, i.e. three assignment algorithms, which we evaluated in Experiment 1A. The aggregate correlations algorithm generated the highest assignment accuracy (70.83% chance = 33.33%) and was selected as the assignment algorithm for the larger sample of individuals and clips within Experiment 1B. The overall assignment accuracy was 33.46% within Experiment 1B (chance = 06.25%), with accuracies ranging from 52.9% (Silver Linings Playbook) to 11.75% (Seinfeld) within individual clips. ISC's were significantly greater than zero for 15 out of 16 clips, and fluctuations within the delta frequency band (i.e. 0-4 Hz) primarily contributed to response similarities across subjects. Interestingly, there was insufficient evidence to indicate that individuals with greater similarities in clip preference demonstrate greater similarities in cortical responses, suggesting a lack of association between ISC and clip preference. Overall these results demonstrate the utility of using ISC's for prediction, and further characterize the relationship between ISC magnitudes and subjective reports.

  19. A novel vascular clip design for the reliable induction of 2-kidney, 1-clip hypertension in the rat

    OpenAIRE

    Chelko, Stephen P.; Schmiedt, Chad W.; Lewis, Tristan H.; Lewis, Stephen J.; Robertson, Tom P.

    2011-01-01

    The 2-kidney, 1-clip (2K1C) model has provided many insights into the pathogenesis of renovascular hypertension. However, studies using the 2K1C model often report low success rates of hypertension, with typical success rates of just 40–60%. We hypothesized that these low success rates are due to fundamental design flaws in the clips traditionally used in 2K1C models. Specifically, the gap widths of traditional silver clips may not be maintained during investigator handling and these clips ma...

  20. CLIP Tool Kit (CTK): a flexible and robust pipeline to analyze CLIP sequencing data.

    Science.gov (United States)

    Shah, Ankeeta; Qian, Yingzhi; Weyn-Vanhentenryck, Sebastien M; Zhang, Chaolin

    2017-02-15

    UV cross-linking and immunoprecipitation (CLIP), followed by high-throughput sequencing, is a powerful biochemical assay that maps in vivo protein-RNA interactions on a genome-wide scale. The CLIP Tool Kit (CTK) aims at providing a set of tools for flexible, streamlined and comprehensive CLIP data analysis. This software package extends the scope of our original CIMS package. The software is implemented in Perl. The source code and detailed documentation are available at http://zhanglab.c2b2.columbia.edu/index.php/CTK . cz2294@columbia.edu. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  1. Modified Clipped LMS Algorithm

    Directory of Open Access Journals (Sweden)

    Lotfizad Mojtaba

    2005-01-01

    Full Text Available Abstract A new algorithm is proposed for updating the weights of an adaptive filter. The proposed algorithm is a modification of an existing method, namely, the clipped LMS, and uses a three-level quantization ( scheme that involves the threshold clipping of the input signals in the filter weight update formula. Mathematical analysis shows the convergence of the filter weights to the optimum Wiener filter weights. Also, it can be proved that the proposed modified clipped LMS (MCLMS algorithm has better tracking than the LMS algorithm. In addition, this algorithm has reduced computational complexity relative to the unmodified one. By using a suitable threshold, it is possible to increase the tracking capability of the MCLMS algorithm compared to the LMS algorithm, but this causes slower convergence. Computer simulations confirm the mathematical analysis presented.

  2. The keyhole GTAW technology: a new welding technology joining quality and productivity; Le procede K-TIG: une nouvelle technologie de soudage combinant qualite et productivite

    Energy Technology Data Exchange (ETDEWEB)

    Le Port, P.; Laugier, M.; Scandella, F.; Lawrjaniec, D. [Institut de Soudure, 57 - Yutz (France); Boucher, Ch. [Institut de Soudure, 93 - Villepinte (France)

    2006-05-15

    This paper is a literature review regarding the keyhole GTAW technology, which has been developed and first used for industrial applications in Australia. The process enables single pass welding of a wide range of materials including stainless steels, titanium and nickel alloys, up to 12 mm thick. Process parameters (welding current, arc voltage, travel speed, the type of shielding gas and tungsten electrode dimensions) are discussed with regards to keyhole formation and stability. A comparison between standard GTAW and keyhole GTAW is provided for the welding of 12 mm thick stainless steel and titanium, showing the substantial increase in productivity that can be achieved with this new technology. Institut de Soudure has taken part in a European project aimed at assessing the possibilities of the keyhole GTAW technology. (authors)

  3. Tailoring weld geometry during keyhole mode laser welding using a genetic algorithm and a heat transfer model

    International Nuclear Information System (INIS)

    Rai, R; DebRoy, T

    2006-01-01

    Tailoring of weld attributes based on scientific principles remains an important goal in welding research. The current generation of unidirectional laser keyhole models cannot determine sets of welding variables that can lead to a particular weld attribute such as specific weld geometry. Here we show how a computational heat transfer model of keyhole mode laser welding can be restructured for systematic tailoring of weld attributes based on scientific principles. Furthermore, the model presented here can calculate multiple sets of laser welding variables, i.e. laser power, welding speed and beam defocus, with each set leading to the same weld pool geometry. Many sets of welding variables were obtained via a global search using a real number-based genetic algorithm, which was combined with a numerical heat transfer model of keyhole laser welding. The reliability of the numerical heat transfer calculations was significantly improved by optimizing values of the uncertain input parameters from a limited volume of experimental data. The computational procedure was applied to the keyhole mode laser welding of the 5182 Al-Mg alloy to calculate various sets of welding variables to achieve a specified weld geometry. The calculated welding parameter sets showed wide variations of the values of welding parameters, but each set resulted in a similar fusion zone geometry. The effectiveness of the computational procedure was examined by comparing the computed weld geometry for each set of welding parameters with the corresponding experimental geometry. The results provide hope that systematic tailoring of weld attributes via multiple pathways, each representing alternative welding parameter sets, is attainable based on scientific principles

  4. Keyhole behavior and liquid flow in molten pool during laser-arc hybrid welding

    Science.gov (United States)

    Naito, Yasuaki; Katayama, Seiji; Matsunawa, Akira

    2003-03-01

    Hybrid welding was carried out on Type 304 stainless steel plate under various conditions using YAG laser combined with TIG arc. During arc and laser-arc hybrid welding, arc voltage variation was measured, and arc plasma, laser-induced plume and evaporation spots as well as keyhole behavior and liquid flow in the molten pool were observed through CCD camera and X-ray real-time transmission apparatus. It was consequently found that hybrid welding possessed many features in comparison with YAG laser welding. The deepest weld bead could be produced when the YAG laser beam of high power density was shot on the molten pool made beforehand stably with TIG arc. A keyhole was long and narrow, and its behavior was rather stable inside the molten pool. It was also confirmed that porosity was reduced by the suppression of bubble formation in hybrid welding utilizing a laser of a moderate power density.

  5. Investigation of mixing and diffusion processes in hybrid spot laser-MIG keyhole welding

    International Nuclear Information System (INIS)

    Zhou, J; Tsai, H L

    2009-01-01

    In hybrid laser-MIG keyhole welding, anti-crack elements can be added into the weld pool through a filler metal in anticipation of compensating mass loss, preventing porosity formation and improving compositional and mechanical properties of the welds. Understanding the mixing and diffusion of the filler metal in the molten pool is vital to achieve these desired objectives. In this study, mathematical models and associated numerical techniques have been developed to investigate the mixing and diffusion processes in hybrid laser-MIG keyhole welding. The transient interactions between droplets and weld pool and dynamics of the melt flow are studied. The effects of key process parameters, such as droplet size (wire diameter), droplet generation frequency (wire feed speed) and droplet impinging speed, on mixing/diffusion are systematically investigated. It was found that compositional homogeneity of the weld pool is determined by the competition between the mixing rate and the solidification rate. A small-size filler droplet together with high generation frequency can increase the latitudinal diffusion of the filler metal into the weld pool, while the large-size droplet along with the low generation frequency helps to get more uniform longitudinal diffusion. Increasing the impinging velocity of the filler droplet can improve the latitudinal diffusion of the filler metal. However, a high impinging velocity can cause a lower diffusion zone in the upper part of the welds. This study provides a good foundation for optimizing the hybrid laser-MIG keyhole welding process to achieve quality welds with desired properties.

  6. Experimental investigation on the weld pool formation process in plasma keyhole arc welding

    Science.gov (United States)

    Van Anh, Nguyen; Tashiro, Shinichi; Van Hanh, Bui; Tanaka, Manabu

    2018-01-01

    This paper seeks to clarify the weld pool formation process in plasma keyhole arc welding (PKAW). We adopted, for the first time, the measurement of the 3D convection inside the weld pool in PKAW by stereo synchronous imaging of tungsten tracer particles using two sets of x-ray transmission systems. The 2D convection on the weld pool surface was also measured using zirconia tracer particles. Through these measurements, the convection in a wide range of weld pools from the vicinity of the keyhole to the rear region was successfully visualized. In order to discuss the heat transport process in a weld pool, the 2D temperature distribution on the weld pool surface was also measured by two-color pyrometry. The results of the comprehensive experimental measurement indicate that the shear force due to plasma flow is found to be the dominant driving force in the weld pool formation process in PKAW. Thus, heat transport in a weld pool is considered to be governed by two large convective patterns near the keyhole: (1) eddy pairs on the surface (perpendicular to the torch axis), and (2) eddy pairs on the bulk of the weld pool (on the plane of the torch). They are formed with an equal velocity of approximately 0.35 m s-1 and are mainly driven by shear force. Furthermore, the flow velocity of the weld pool convection becomes considerably higher than that of other welding processes, such as TIG welding and GMA welding, due to larger plasma flow velocity.

  7. Towards Fast Tracking of the Keyhole Geometry

    Science.gov (United States)

    Brock, C.; Hohenstein, R.; Schmidt, M.

    We describe a sensor principle permitting the fast online measurement of the position of the optical process emissions in deep penetration laser welding. Experiments show a strong correlation between the position of the vapour plume and the keyhole geometry, demonstrated here by varying the penetration depth of the weld. In order to achieve an absolute position measurement, the sensor was calibrated using a light source with well defined characteristics. The setup for the calibration measurements and the corresponding data evaluation methods are discussed. The precision of the calibration with a green LED is 6 μm in lateral and 55 μm in axial direction, for a working distance of 200 mm.

  8. Sepsis from dropped clips at laparoscopic cholecystectomy

    International Nuclear Information System (INIS)

    Hussain, Sarwat

    2001-01-01

    We report seven patients in whom five dropped surgical clips and two gallstones were visualized in the peritoneal cavity, on radiological studies. In two, subphrenic abscesses and empyemas developed as a result of dropped clips into the peritoneal cavity during or following laparoscopic cholecystectomy. In one of these two, a clip was removed surgically from the site of an abscess. In two other patients dropped gallstones, and in three, dropped clips led to no complications. These were seen incidentally on studies done for other indications. Abdominal abscess secondary to dropped gallstones is a well-recognized complication of laparoscopic cholecystectomy (LC). We conclude that even though dropped surgical clips usually do not cause problems, they should be considered as a risk additional to other well-known causes of post-LC abdominal sepsis

  9. CLIPS - C LANGUAGE INTEGRATED PRODUCTION SYSTEM (MACINTOSH VERSION)

    Science.gov (United States)

    Culbert, C.

    1994-01-01

    The C Language Integrated Production System, CLIPS, is a shell for developing expert systems. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. The primary design goals for CLIPS are portability, efficiency, and functionality. For these reasons, the program is written in C. CLIPS meets or outperforms most micro- and minicomputer based artificial intelligence tools. CLIPS is a forward chaining rule-based language. The program contains an inference engine and a language syntax that provide a framework for the construction of an expert system. It also includes tools for debugging an application. CLIPS is based on the Rete algorithm, which enables very efficient pattern matching. The collection of conditions and actions to be taken if the conditions are met is constructed into a rule network. As facts are asserted either prior to or during a session, CLIPS pattern-matches the number of fields. Wildcards and variables are supported for both single and multiple fields. CLIPS syntax allows the inclusion of externally defined functions (outside functions which are written in a language other than CLIPS). CLIPS itself can be embedded in a program such that the expert system is available as a simple subroutine call. Advanced features found in CLIPS version 4.3 include an integrated microEMACS editor, the ability to generate C source code from a CLIPS rule base to produce a dedicated executable, binary load and save capabilities for CLIPS rule bases, and the utility program CRSV (Cross-Reference, Style, and Verification) designed to facilitate the development and maintenance of large rule bases. Five machine versions are available. Each machine version includes the source and the executable for that machine. The UNIX version includes the source and binaries for IBM RS/6000, Sun3 series, and Sun4 series computers. The UNIX, DEC VAX, and DEC RISC Workstation versions are line oriented. The PC version and the Macintosh

  10. 3D Simulations of the ``Keyhole'' Hohlraum for Shock Timing on NIF

    Science.gov (United States)

    Robey, H. F.; Marinak, M. M.; Munro, D. H.; Jones, O. S.

    2007-11-01

    Ignition implosions planned for the National Ignition Facility (NIF) require a pulse shape with a carefully designed series of steps, which launch a series of shocks through the ablator and DT fuel. The relative timing of these shocks must be tuned to better than +/- 100ps to maintain the DT fuel on a sufficiently low adiabat. To meet these requirements, pre-ignition tuning experiments using a modified hohlraum geometry are being planned. This modified geometry, known as the ``keyhole'' hohlraum, adds a re-entrant gold cone, which passes through the hohlraum and capsule walls, to provide an optical line-of-sight to directly measure the shocks as they break out of the ablator. In order to assess the surrogacy of this modified geometry, 3D simulations using HYDRA [1] have been performed. The drive conditions and the resulting effect on shock timing in the keyhole hohlraum will be compared with the corresponding results for the standard ignition hohlraum. [1] M.M. Marinak, et al., Phys. Plasmas 8, 2275 (2001).

  11. Geospatial Visualization of Scientific Data Through Keyhole Markup Language

    Science.gov (United States)

    Wernecke, J.; Bailey, J. E.

    2008-12-01

    The development of virtual globes has provided a fun and innovative tool for exploring the surface of the Earth. However, it has been the paralleling maturation of Keyhole Markup Language (KML) that has created a new medium and perspective through which to visualize scientific datasets. Originally created by Keyhole Inc., and then acquired by Google in 2004, in 2007 KML was given over to the Open Geospatial Consortium (OGC). It became an OGC international standard on 14 April 2008, and has subsequently been adopted by all major geobrowser developers (e.g., Google, Microsoft, ESRI, NASA) and many smaller ones (e.g., Earthbrowser). By making KML a standard at a relatively young stage in its evolution, developers of the language are seeking to avoid the issues that plagued the early World Wide Web and development of Hypertext Markup Language (HTML). The popularity and utility of Google Earth, in particular, has been enhanced by KML features such as the Smithsonian volcano layer and the dynamic weather layers. Through KML, users can view real-time earthquake locations (USGS), view animations of polar sea-ice coverage (NSIDC), or read about the daily activities of chimpanzees (Jane Goodall Institute). Perhaps even more powerful is the fact that any users can create, edit, and share their own KML, with no or relatively little knowledge of manipulating computer code. We present an overview of the best current scientific uses of KML and a guide to how scientists can learn to use KML themselves.

  12. Pontine infarction caused by medial branch injury of the basilar artery as a rare complication of cisternal drain placement

    OpenAIRE

    Horiuchi, Tetsuyoshi; Yamamoto, Yasunaga; Kuroiwa, Masafumi; Rahmah, Nunung Nur; Hongo, Kazuhiro

    2012-01-01

    We present a rare complication of cisternal drain placement during aneurysm surgery. A ruptured anterior communicating artery aneurysm was clipped through a right pterional approach. A cisternal drain was inserted from the retro-carotid to the prepontine cistern. Postoperatively, a left-sided paresis of the upper extremity had developed. A CT brain scan revealed that the drain was located between the pons and the basilar artery, resulting in a pontine infarction. Vascular neurosurgeons should...

  13. A novel vascular clip design for the reliable induction of 2-kidney, 1-clip hypertension in the rat.

    Science.gov (United States)

    Chelko, Stephen P; Schmiedt, Chad W; Lewis, Tristan H; Lewis, Stephen J; Robertson, Tom P

    2012-02-01

    The 2-kidney, 1-clip (2K1C) model has provided many insights into the pathogenesis of renovascular hypertension. However, studies using the 2K1C model often report low success rates of hypertension, with typical success rates of just 40-60%. We hypothesized that these low success rates are due to fundamental design flaws in the clips traditionally used in 2K1C models. Specifically, the gap widths of traditional silver clips may not be maintained during investigator handling and these clips may also be easily dislodged from the renal artery following placement. Therefore, we designed and tested a novel vascular clip possessing design features to maintain both gap width and position around the renal artery. In this initial study, application of these new clips to the left renal artery produced reliable and consistent levels of hypertension in rats. Nine-day application of clips with gap widths of 0.27, 0.25, and 0.23 mm elicited higher mean arterial blood pressures of 112 ± 4, 121 ± 6, and 135 ± 7 mmHg, respectively (n = 8 for each group), than those of sham-operated controls (95 ± 2 mmHg, n = 8). Moreover, 8 out of 8 rats in each of the 0.23 and 0.25 mm 2K1C groups were hypertensive, whereas 7 out of 8 rats in the 0.27 mm 2K1C group were hypertensive. Plasma renin concentrations were also increased in all 2K1C groups compared with sham-operated controls. In summary, this novel clip design may help eliminate the large degree of unreliability commonly encountered with the 2K1C model.

  14. Anesthesia management for MitraClip device implantation

    Directory of Open Access Journals (Sweden)

    Harikrishnan Kothandan

    2014-01-01

    Full Text Available Aims and Objectives: Percutaneous MitraClip implantation has been demonstrated as an alternative procedure in high-risk patients with symptomatic severe mitral regurgitation (MR who are not suitable (or denied mitral valve repair/replacement due to excessive co morbidity. The MitraClip implantation was performed under general anesthesia and with 3-dimensional transesophageal echocardiography (TEE and fluoroscopic guidance. Materials and Methods: Peri-operative patient data were extracted from the electronic and paper medical records of 21 patients who underwent MitraClip implantations. Results: Four MitraClip implantation were performed in the catheterization laboratory; remaining 17 were performed in the hybrid operating theatre. In 2 patients, procedure was aborted, in one due to migration of the Chiari network into the left atrium and in second one, the leaflets and chords of the mitral valve torn during clipping resulting in consideration for open surgery. In the remaining 19 patients, MitraClip was implanted and the patients showed acute reduction of severe MR to mild-moderate MR. All the patients had invasive blood pressure monitoring and the initial six patients had central venous catheterization prior to the procedure. Intravenous heparin was administered after the guiding catheter was introduced through the inter-atrial septum and activated clotting time was maintained beyond 250 s throughout the procedure. Protamine was administered at the end of the procedure. All the patients were monitored in the intensive care unit after the procedure. Conclusions: Percutaneous MitraClip implantation is a feasible alternative in high-risk patients with symptomatic severe MR. Anesthesia management requirements are similar to open surgical mitral valve repair or replacement. TEE plays a vital role during the MitraClip implantation.

  15. Vertical diplopia and oscillopsia due to midbrain keyhole aqueduct syndrome associated with severe cough.

    Science.gov (United States)

    Oh, Angela Jinsook; Lanzman, Bryan Alexander; Liao, Yaping Joyce

    2018-06-01

    Midline structural defects in the neural axis can give rise to neuro-ophthalmic symptoms. We report a rare case of keyhole aqueduct syndrome presenting after two years of severe cough due to gastroesophageal reflux disease. A 58-year-old woman with a 2-year history of daily, severe cough presented to the neuro-ophthalmology clinic with progressive diplopia and oscillopsia. Examination revealed a 1-2 Hz down-beating nystagmus in primary gaze that worsened with left, right, and down gazes. Gaze evoked nystagmus and mild paresis were also seen with up gaze. There was an incomitant left hypertropia due to skew deviation that worsened with right and up gazes and improved with down gaze. She also had a right-sided ptosis and a 3 mm anisocoria not due to cranial nerve 3 paresis or Horner's syndrome. Brain magnetic resonance imaging showed a 1.5 mm × 11.7 mm × 6 mm midline cleft in the ventral midbrain communicating with the cerebral aqueduct, consistent with keyhole aqueduct syndrome. Her nystagmus and diplopia improved with oral acetazolamide treatment, at high doses of 2500-3000 mg per day. We report the first case of midbrain keyhole aqueduct syndrome with ocular motor and other neuro-ophthalmic manifestations associated with severe cough. Although her cough was effectively treated and intracranial pressure measurement was normal, her ophthalmic symptoms continued to progress, which is common in previous cases reported. Treatment with acetazolamide led to significant improvement, supporting the use of acetazolamide in this rare condition.

  16. Recurrence of ICA-PCoA aneurysms after neck clipping.

    Science.gov (United States)

    Sakaki, T; Takeshima, T; Tominaga, M; Hashimoto, H; Kawaguchi, S

    1994-01-01

    Between 1975 and 1992, 2211 patients underwent aneurysmal neck clipping at the Nara Medical University clinic and associated hospitals. The aneurysm in 931 of these patients was situated at the junction of the internal carotid artery (ICA) and posterior communicating artery (PCoA). Seven patients were readmitted 4 to 17 years after the first surgery because of regrowth and rupture of an ICA-PCoA aneurysmal sac that had arisen from the residual neck. On angiograms obtained following aneurysmal neck clipping, a large primitive type of PCoA was demonstrated in six patients and a small PCoA in one. A small residual aneurysm was confirmed in only two patients and angiographically complete neck clipping in five. Recurrent ICA-PCoA aneurysms were separated into two types based on the position of the old clip in relation to the new growth. Type 1 aneurysms regrow from the entire neck and balloon eccentrically. In this type, it is possible to apply the clip at the neck as in conventional clipping for a ruptured aneurysm. Type 2 includes aneurysms in which the proximal portion of a previous clip is situated at the corner of the ICA and aneurysmal neck and the distal portion on the enlarged dome of the aneurysm, because the sac is regrowing from a portion of the residual neck. In this type of aneurysm, a Sugita fenestrated clip can occlude the residual neck, overriding the old clip. Classifying these aneurysms into two groups is very useful from a surgical point of view because it is possible to apply a new clip without removing the old clip, which was found to be adherent to surrounding tissue.

  17. Journal of Clipped Words in Reader's Digest Magazine

    OpenAIRE

    Simanjuntak, Lestari

    2012-01-01

    This study deals with Clipped Words in the “Laughter, the Best Medicine” of Reader's Digest. The objectives of the study are to find out the types of clipped words which are used in the “Laughter, the Best Medicine” of Reader's Digest, to find out sthe dominantly used in the whole story and to reason the dominant clipped word use in the text. The study use descriptive qualitative method. The data were collected from seventeen selected Reader's Digest which contains the clipped word by applie...

  18. 21 CFR 868.6225 - Nose clip.

    Science.gov (United States)

    2010-04-01

    ... ANESTHESIOLOGY DEVICES Miscellaneous § 868.6225 Nose clip. (a) Identification. A nose clip is a device intended to close a patient's external nares (nostrils) during diagnostic or therapeutic procedures. (b... from the current good manufacturing practice requirements of the quality system regulation in part 820...

  19. 21 CFR 886.1410 - Ophthalmic trial lens clip.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens clip. 886.1410 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1410 Ophthalmic trial lens clip. (a) Identification. An ophthalmic trial lens clip is a device intended to hold prisms, spheres, cylinders, or...

  20. Biocompatibility of Plastic Clip in Neurocranium - Experimental Study on Dogs.

    Science.gov (United States)

    Delibegovic, Samir; Dizdarevic, Kemal; Cickusic, Elmir; Katica, Muhamed; Obhodjas, Muamer; Ocus, Muhamed

    2016-01-01

    A potential advantage of the use of the plastic clips in neurosurgery is their property of causing fewer artifacts than titanium clips as assessed by computed tomography and magnetic resonance scans. The biocompatibility of plastic clips was demonstrated in the peritoneal cavity, but their behavior in the neurocranium is not known. Twelve aggressive stray dogs designated for euthanasia were taken for this experimental study. The animals were divided into two groups. In all cases, after anesthesia, a craniotomy was performed, and after opening the dura, a proximal part titanium clip was placed on the isolated superficial Sylvian vein (a permanent Yasargil FT 746 T clip at a 90° angle, while a plastic Hem-o-lok clip ML was placed on another part of the vein). The first group of animals was sacrificed on the 7 th postoperative day and the second group on the 60 th postoperative day. Samples of tissue around the clips were taken for a histopathological evaluation. The plastic clip caused a more intensive tissue reaction than the titanium clip on the 7 th postoperative day, but there was no statistical difference. Even on the 60 th postoperative day there was no significant difference in tissue reaction between the titanium and plastic clips. These preliminary results confirm the possibility for the use of plastic clips in neurosurgery. Before their use in human neurosurgery, further studies are needed to investigate the long-term effects of the presence of plastic clips in the neurocranium, as well as studies of the aneurysmal model.

  1. CLIPS - C LANGUAGE INTEGRATED PRODUCTION SYSTEM (IBM PC VERSION)

    Science.gov (United States)

    Riley, G.

    1994-01-01

    The C Language Integrated Production System, CLIPS, is a shell for developing expert systems. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. The primary design goals for CLIPS are portability, efficiency, and functionality. For these reasons, the program is written in C. CLIPS meets or outperforms most micro- and minicomputer based artificial intelligence tools. CLIPS is a forward chaining rule-based language. The program contains an inference engine and a language syntax that provide a framework for the construction of an expert system. It also includes tools for debugging an application. CLIPS is based on the Rete algorithm, which enables very efficient pattern matching. The collection of conditions and actions to be taken if the conditions are met is constructed into a rule network. As facts are asserted either prior to or during a session, CLIPS pattern-matches the number of fields. Wildcards and variables are supported for both single and multiple fields. CLIPS syntax allows the inclusion of externally defined functions (outside functions which are written in a language other than CLIPS). CLIPS itself can be embedded in a program such that the expert system is available as a simple subroutine call. Advanced features found in CLIPS version 4.3 include an integrated microEMACS editor, the ability to generate C source code from a CLIPS rule base to produce a dedicated executable, binary load and save capabilities for CLIPS rule bases, and the utility program CRSV (Cross-Reference, Style, and Verification) designed to facilitate the development and maintenance of large rule bases. Five machine versions are available. Each machine version includes the source and the executable for that machine. The UNIX version includes the source and binaries for IBM RS/6000, Sun3 series, and Sun4 series computers. The UNIX, DEC VAX, and DEC RISC Workstation versions are line oriented. The PC version and the Macintosh

  2. Mounting clips for panel installation

    Science.gov (United States)

    Cavieres, Andres; Al-Haddad, Tristan; Goodman, Joseph

    2017-07-11

    A photovoltaic panel mounting clip comprising a base, central indexing tabs, flanges, lateral indexing tabs, and vertical indexing tabs. The mounting clip removably attaches one or more panels to a beam or the like structure, both mechanically and electrically. It provides secure locking of the panels in all directions, while providing guidance in all directions for accurate installation of the panels to the beam or the like structure.

  3. Chinese Language Video Clips. [CD-ROM].

    Science.gov (United States)

    Fleming, Stephen; Hipley, David; Ning, Cynthia

    This compact disc includes video clips covering six topics for the learner of Chinese: personal information, commercial transactions, travel and leisure, health and sports, food and school. Filmed on location in Beijing, these naturalistic video clips consist mainly of unrehearsed interviews of ordinary people. The learner is lead through a series…

  4. Development of an artifact-free aneurysm clip

    Directory of Open Access Journals (Sweden)

    Brack Alexander

    2016-09-01

    Full Text Available For the treatment of intracranial aneurysms with aneurysm clips, usually a follow-up inspection in MRI is required. To avoid any artifacts, which can make a proper diagnosis difficult, a new approach for the manufacturing of an aneurysm clip entirely made from fiber-reinforced plastics has been developed. In this paper the concept for the design of the clip, the development of a new manufacturing technology for the fiber-reinforced components as well as first results from the examination of the components in phantom MRI testing is shown.

  5. Improvement of laser keyhole formation with the assistance of arc plasma in the hybrid welding process of magnesium alloy

    Science.gov (United States)

    Liu, Liming; Hao, Xinfeng

    2009-11-01

    In the previous work, low-power laser/arc hybrid welding technique is used to weld magnesium alloy and high-quality weld joints are obtained. In order to make clear the interactions between low-power laser pulse and arc plasma, the effect of arc plasma on laser pulse is studied in this article. The result shows that the penetration of low-power laser welding with the assistance of TIG arc is more than two times deeper than that of laser welding alone and laser welding transforms from thermal-conduction mode to keyhole mode. The plasma behaviors and spectra during the welding process are studied, and the transition mechanism of laser-welding mode is analyzed in detail. It is also found that with the assistance of arc plasma, the threshold value of average power density to form keyhole welding for YAG laser is only 3.3×10 4 W/cm 2, and the average peak power density is 2.6×10 5 W/cm 2 in the present experiment. Moreover, the distribution of energy density during laser pulse is modulated to improve the formation and stability of laser keyholes.

  6. Digital video clips for improved pedagogy and illustration of scientific research — with illustrative video clips on atomic spectrometry

    Science.gov (United States)

    Michel, Robert G.; Cavallari, Jennifer M.; Znamenskaia, Elena; Yang, Karl X.; Sun, Tao; Bent, Gary

    1999-12-01

    This article is an electronic publication in Spectrochimica Acta Electronica (SAE), a section of Spectrochimica Acta Part B (SAB). The hardcopy text is accompanied by an electronic archive, stored on the CD-ROM accompanying this issue. The archive contains video clips. The main article discusses the scientific aspects of the subject and explains the purpose of the video files. Short, 15-30 s, digital video clips are easily controllable at the computer keyboard, which gives a speaker the ability to show fine details through the use of slow motion. Also, they are easily accessed from the computer hard drive for rapid extemporaneous presentation. In addition, they are easily transferred to the Internet for dissemination. From a pedagogical point of view, the act of making a video clip by a student allows for development of powers of observation, while the availability of the technology to make digital video clips gives a teacher the flexibility to demonstrate scientific concepts that would otherwise have to be done as 'live' demonstrations, with all the likely attendant misadventures. Our experience with digital video clips has been through their use in computer-based presentations by undergraduate and graduate students in analytical chemistry classes, and by high school and middle school teachers and their students in a variety of science and non-science classes. In physics teaching laboratories, we have used the hardware to capture digital video clips of dynamic processes, such as projectiles and pendulums, for later mathematical analysis.

  7. Keyhole craniotomy through retrosigmoid approach followed by microvascular decompression for primary trigeminal neuralgia:a report of 23 cases

    Directory of Open Access Journals (Sweden)

    Gang-ge CHENG

    2011-03-01

    Full Text Available Objective To explore the surgical technique,effects,and complications of keyhole craniotomy through retrosigmoid approach followed by microvascular decompression for primary trigeminal neuralgia.Methods The craniotomy with a keyhole incision above postauricular hairline followed by microvascular decompression was performed in 23 patients with primary trigeminal neuralgia.Dissection of intracranial part of trigeminal nerve under microscope was done to search for the offending vessels,which were thereby freed and between which and the root entry zone(REZ of trigeminal nerve the Teflon grafts were placed.Effects and complications were observed in follow-up,ranging from 1 month to 2 years.Results Out of 23 patients who were all found compression in REZ of trigeminal nerves by the offending vessels in operation,disappearance of symptoms post-surgery was found in 22 cases,face numbness on the surgical side in 3 cases and no effects in 1 case.Recurrence of pain was not observed in patients who had initially benefited from the surgery at the follow-up.Conclusion The keyhole craniotomy through retrosigmoid approach followed by microvascular decompression is safe and effective for primary trigeminal neuralgia,in which accurate technique during operation plays a vital role in the decrease of complications and the outcome post-surgery.

  8. A defect in the CLIP1 gene (CLIP-170) can cause autosomal recessive intellectual disability

    OpenAIRE

    Larti, Farzaneh; Kahrizi, Kimia; Musante, Luciana; Hu, Hao; Papari, Elahe; Fattahi, Zohreh; Bazazzadegan, Niloofar; Liu, Zhe; Banan, Mehdi; Garshasbi, Masoud; Wienker, Thomas F; Hilger Ropers, H; Galjart, Niels; Najmabadi, Hossein

    2015-01-01

    In the context of a comprehensive research project, investigating novel autosomal recessive intellectual disability (ARID) genes, linkage analysis based on autozygosity mapping helped identify an intellectual disability locus on Chr.12q24, in an Iranian family (LOD score=3.7). Next-generation sequencing (NGS) following exon enrichment in this novel interval, detected a nonsense mutation (p.Q1010*) in the CLIP1 gene. CLIP1 encodes a member of microtubule (MT) plus-end tracking proteins, which ...

  9. A model-based approach to identify binding sites in CLIP-Seq data.

    Directory of Open Access Journals (Sweden)

    Tao Wang

    Full Text Available Cross-linking immunoprecipitation coupled with high-throughput sequencing (CLIP-Seq has made it possible to identify the targeting sites of RNA-binding proteins in various cell culture systems and tissue types on a genome-wide scale. Here we present a novel model-based approach (MiClip to identify high-confidence protein-RNA binding sites from CLIP-seq datasets. This approach assigns a probability score for each potential binding site to help prioritize subsequent validation experiments. The MiClip algorithm has been tested in both HITS-CLIP and PAR-CLIP datasets. In the HITS-CLIP dataset, the signal/noise ratios of miRNA seed motif enrichment produced by the MiClip approach are between 17% and 301% higher than those by the ad hoc method for the top 10 most enriched miRNAs. In the PAR-CLIP dataset, the MiClip approach can identify ∼50% more validated binding targets than the original ad hoc method and two recently published methods. To facilitate the application of the algorithm, we have released an R package, MiClip (http://cran.r-project.org/web/packages/MiClip/index.html, and a public web-based graphical user interface software (http://galaxy.qbrc.org/tool_runner?tool_id=mi_clip for customized analysis.

  10. Integrating CLIPS applications into heterogeneous distributed systems

    Science.gov (United States)

    Adler, Richard M.

    1991-01-01

    SOCIAL is an advanced, object-oriented development tool for integrating intelligent and conventional applications across heterogeneous hardware and software platforms. SOCIAL defines a family of 'wrapper' objects called agents, which incorporate predefined capabilities for distributed communication and control. Developers embed applications within agents and establish interactions between distributed agents via non-intrusive message-based interfaces. This paper describes a predefined SOCIAL agent that is specialized for integrating C Language Integrated Production System (CLIPS)-based applications. The agent's high-level Application Programming Interface supports bidirectional flow of data, knowledge, and commands to other agents, enabling CLIPS applications to initiate interactions autonomously, and respond to requests and results from heterogeneous remote systems. The design and operation of CLIPS agents are illustrated with two distributed applications that integrate CLIPS-based expert systems with other intelligent systems for isolating and mapping problems in the Space Shuttle Launch Processing System at the NASA Kennedy Space Center.

  11. 21 CFR 886.3100 - Ophthalmic tantalum clip.

    Science.gov (United States)

    2010-04-01

    ... blood vessels in the eye. (b) Classification. Class II (special controls). The device is exempt from the...) MEDICAL DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3100 Ophthalmic tantalum clip. (a) Identification. An ophthalmic tantalum clip is a malleable metallic device intended to be implanted permanently...

  12. Percutaneous interventional mitral regurgitation treatment using the Mitra-Clip system

    DEFF Research Database (Denmark)

    Boekstegers, P; Hausleiter, J; Baldus, S

    2014-01-01

    The interventional treatment of mitral valve regurgitation by the MitraClip procedure has grown rapidly in Germany and Europe during the past years. The MitraClip procedure has the potential to treat high-risk patients with secondary mitral valve regurgitation and poor left ventricular function....... Furthermore, patients with primary mitral valve regurgitation may be treated successfully by the MitraClip procedure in case of high surgical risk or in very old patients. At the same time it has been emphasised that the MitraClip interventional treatment is still at an early stage of clinical development....... The largest clinical experience with the MitraClip procedure so far is probably present in some German cardiovascular centers, which here summarise their recommendations on the current indications and procedural steps of the MitraClip treatment. These recommendations of the AGIK and ALKK may present a basis...

  13. Hardware Implementation Of Line Clipping A lgorithm By Using FPGA

    Directory of Open Access Journals (Sweden)

    Amar Dawod

    2013-04-01

    Full Text Available The computer graphics system performance is increasing faster than any other computing application. Algorithms for line clipping against convex polygons and lines have been studied for a long time and many research papers have been published so far. In spite of the latest graphical hardware development and significant increase of performance the clipping is still a bottleneck of any graphical system. So its implementation in hardware is essential for real time applications. In this paper clipping operation is discussed and a hardware implementation of the line clipping algorithm is presented and finally formulated and tested using Field Programmable Gate Arrays (FPGA. The designed hardware unit consists of two parts : the first is positional code generator unit and the second is the clipping unit. Finally it is worth mentioning that the  designed unit is capable of clipping (232524 line segments per second.       

  14. Speed Biases With Real-Life Video Clips

    Directory of Open Access Journals (Sweden)

    Federica Rossi

    2018-03-01

    Full Text Available We live almost literally immersed in an artificial visual world, especially motion pictures. In this exploratory study, we asked whether the best speed for reproducing a video is its original, shooting speed. By using adjustment and double staircase methods, we examined speed biases in viewing real-life video clips in three experiments, and assessed their robustness by manipulating visual and auditory factors. With the tested stimuli (short clips of human motion, mixed human-physical motion, physical motion and ego-motion, speed underestimation was the rule rather than the exception, although it depended largely on clip content, ranging on average from 2% (ego-motion to 32% (physical motion. Manipulating display size or adding arbitrary soundtracks did not modify these speed biases. Estimated speed was not correlated with estimated duration of these same video clips. These results indicate that the sense of speed for real-life video clips can be systematically biased, independently of the impression of elapsed time. Measuring subjective visual tempo may integrate traditional methods that assess time perception: speed biases may be exploited to develop a simple, objective test of reality flow, to be used for example in clinical and developmental contexts. From the perspective of video media, measuring speed biases may help to optimize video reproduction speed and validate “natural” video compression techniques based on sub-threshold temporal squeezing.

  15. A method of handing down surgical clipping technique for cerebral aneurysm

    International Nuclear Information System (INIS)

    Idei, Masaru; Yamane, Kanji; Okita, Shinji; Kumano, Kiyoshi; Nakae, Ryuta

    2009-01-01

    Meticulous clipping techniques are essential to obtain good results. Recently, the introduction of intravascular surgery for cerebral aneurysms has decreased the number of the direct clipping surgeries. And the increasing number of the lawsuits against doctors further discourages young surgeons from attempting clipping. As a result, young neurosurgeons, have less experience performing clipping. Therefore, we must learn clipping techniques from expert neurosurgeons under the limitation of having fewer opportunities to perform clipping surgery. In this paper, I present my experiences and discuss ways to obtain techniques for clipping surgery. I performed surgical clipping in 19 cases, 12 unruptured and 7 ruptured aneurysms, 7 males and 12 females aged from 36 to 79 years old (mean 61.9 years). Postoperatively, there were no symptomatic complications, but there were 2 asymptomatic infarctions that were revealed on CT scan. Intraoperative premature rupture occurred in 1 patient with a ruptured aneurysm. Techniques of manipulation with micro-forceps, suction and spatula are required for successful clipping. Off-the-job training of dissecting chicken wing arteries and rat abdominal aortas and vena cavas is useful. Moreover, actual experiences of surgical operations are essential. Surgical experiences raise the motivation of young neurosurgeons and encourage them to train more. We believe that this benign cycle contributes to meticulous surgical skills. (author)

  16. Semantic Labeling of Nonspeech Audio Clips

    Directory of Open Access Journals (Sweden)

    Xiaojuan Ma

    2010-01-01

    Full Text Available Human communication about entities and events is primarily linguistic in nature. While visual representations of information are shown to be highly effective as well, relatively little is known about the communicative power of auditory nonlinguistic representations. We created a collection of short nonlinguistic auditory clips encoding familiar human activities, objects, animals, natural phenomena, machinery, and social scenes. We presented these sounds to a broad spectrum of anonymous human workers using Amazon Mechanical Turk and collected verbal sound labels. We analyzed the human labels in terms of their lexical and semantic properties to ascertain that the audio clips do evoke the information suggested by their pre-defined captions. We then measured the agreement with the semantically compatible labels for each sound clip. Finally, we examined which kinds of entities and events, when captured by nonlinguistic acoustic clips, appear to be well-suited to elicit information for communication, and which ones are less discriminable. Our work is set against the broader goal of creating resources that facilitate communication for people with some types of language loss. Furthermore, our data should prove useful for future research in machine analysis/synthesis of audio, such as computational auditory scene analysis, and annotating/querying large collections of sound effects.

  17. Clip, connect, clone

    DEFF Research Database (Denmark)

    Fujima, Jun; Lunzer, Aran; Hornbæk, Kasper

    2010-01-01

    using three mechanisms: clipping of input and result elements from existing applications to form cells on a spreadsheet; connecting these cells using formulas, thus enabling result transfer between applications; and cloning cells so that multiple requests can be handled side by side. We demonstrate...

  18. Current MitraClip experience, safety and feasibility in the Netherlands

    NARCIS (Netherlands)

    Rahhab, Z.; Kortlandt, F. A.; Velu, J. F.; Schurer, R. A. J.; Delgado, V.; Tonino, P.; Boven, A. J.; van den Branden, B. J. L.; Kraaijeveld, A. O.; Voskuil, M.; Hoorntje, J.; van Wely, M. [=Marleen; van Houwelingen, K.; Bleeker, G. B.; Rensing, B.; Kardys, I.; Baan, J.; van der Heyden, J. A. S.; van Mieghem, N. M.

    2017-01-01

    Purpose Data on MitraClip procedural safety and efficacy in the Netherlands are scarce. We aim to provide an overview of the Dutch MitraClip experience. Methods We pooled anonymised demographic and procedural data of 1151 consecutive MitraClip patients, from 13 Dutch hospitals. Data was collected by

  19. Diagnostic applications of nail clippings.

    Science.gov (United States)

    Stephen, Sasha; Tosti, Antonella; Rubin, Adam I

    2015-04-01

    "Nail clipping is a simple technique for diagnosis of several nail unit dermatoses. This article summarizes the practical approach, utility, and histologic findings of a nail clipping in evaluation of onychomycosis, nail unit psoriasis, onychomatricoma, subungual hematoma, melanonychia, and nail cosmetics, and the forensic applications of this easily obtained specimen. It reviews important considerations in optimizing specimen collection, processing methods, and efficacy of special stains in several clinical contexts. Readers will develop a greater understanding and ease of application of this indispensable procedure in assessing nail unit dermatoses." Copyright © 2015 Elsevier Inc. All rights reserved.

  20. On the performance of dual-hop systems with multiple antennas: Effects of spatial correlation, keyhole, and co-channel interference

    KAUST Repository

    Yang, Liang

    2012-12-01

    In this paper, taking into account realistic propagation conditions, namely, spatial correlation, keyhole channels, and unequal-power co-channel interference, we investigate the performance of a wireless relay network where all the nodes are equipped with multiple antennas. Considering channel state information assisted amplify-and-forward protocol, we present analytical expressions for the symbol error rate (SER) and outage probability. More specifically, we first derive the SER expressions of a relay system with orthogonal space-time block coding (OSTBC) over correlated/keyhole fading channels. We also analyze the outage probability of interference corrupted relay systems with maximal ratio combing (MRC) at the receiver as well as multiple-input multiple-output MRC (MIMO MRC). Numerical results are given to illustrate and verify the analytical results. © 2012 IEEE.

  1. On the performance of dual-hop systems with multiple antennas: Effects of spatial correlation, keyhole, and co-channel interference

    KAUST Repository

    Yang, Liang; Alouini, Mohamed-Slim; Qaraqe, Khalid A.; Liu, Weiping

    2012-01-01

    In this paper, taking into account realistic propagation conditions, namely, spatial correlation, keyhole channels, and unequal-power co-channel interference, we investigate the performance of a wireless relay network where all the nodes are equipped with multiple antennas. Considering channel state information assisted amplify-and-forward protocol, we present analytical expressions for the symbol error rate (SER) and outage probability. More specifically, we first derive the SER expressions of a relay system with orthogonal space-time block coding (OSTBC) over correlated/keyhole fading channels. We also analyze the outage probability of interference corrupted relay systems with maximal ratio combing (MRC) at the receiver as well as multiple-input multiple-output MRC (MIMO MRC). Numerical results are given to illustrate and verify the analytical results. © 2012 IEEE.

  2. CLIPS - C LANGUAGE INTEGRATED PRODUCTION SYSTEM (IBM PC VERSION WITH CLIPSITS)

    Science.gov (United States)

    Riley, , .

    1994-01-01

    The C Language Integrated Production System, CLIPS, is a shell for developing expert systems. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. The primary design goals for CLIPS are portability, efficiency, and functionality. For these reasons, the program is written in C. CLIPS meets or outperforms most micro- and minicomputer based artificial intelligence tools. CLIPS is a forward chaining rule-based language. The program contains an inference engine and a language syntax that provide a framework for the construction of an expert system. It also includes tools for debugging an application. CLIPS is based on the Rete algorithm, which enables very efficient pattern matching. The collection of conditions and actions to be taken if the conditions are met is constructed into a rule network. As facts are asserted either prior to or during a session, CLIPS pattern-matches the number of fields. Wildcards and variables are supported for both single and multiple fields. CLIPS syntax allows the inclusion of externally defined functions (outside functions which are written in a language other than CLIPS). CLIPS itself can be embedded in a program such that the expert system is available as a simple subroutine call. Advanced features found in CLIPS version 4.3 include an integrated microEMACS editor, the ability to generate C source code from a CLIPS rule base to produce a dedicated executable, binary load and save capabilities for CLIPS rule bases, and the utility program CRSV (Cross-Reference, Style, and Verification) designed to facilitate the development and maintenance of large rule bases. Five machine versions are available. Each machine version includes the source and the executable for that machine. The UNIX version includes the source and binaries for IBM RS/6000, Sun3 series, and Sun4 series computers. The UNIX, DEC VAX, and DEC RISC Workstation versions are line oriented. The PC version and the Macintosh

  3. Receiver-based recovery of clipped ofdm signals for papr reduction: A bayesian approach

    KAUST Repository

    Ali, Anum

    2014-01-01

    Clipping is one of the simplest peak-to-average power ratio reduction schemes for orthogonal frequency division multiplexing (OFDM). Deliberately clipping the transmission signal degrades system performance, and clipping mitigation is required at the receiver for information restoration. In this paper, we acknowledge the sparse nature of the clipping signal and propose a low-complexity Bayesian clipping estimation scheme. The proposed scheme utilizes a priori information about the sparsity rate and noise variance for enhanced recovery. At the same time, the proposed scheme is robust against inaccurate estimates of the clipping signal statistics. The undistorted phase property of the clipped signal, as well as the clipping likelihood, is utilized for enhanced reconstruction. Furthermore, motivated by the nature of modern OFDM-based communication systems, we extend our clipping reconstruction approach to multiple antenna receivers and multi-user OFDM.We also address the problem of channel estimation from pilots contaminated by the clipping distortion. Numerical findings are presented that depict favorable results for the proposed scheme compared to the established sparse reconstruction schemes.

  4. View-sharing in keyhole imaging: Partially compressed central k-space acquisition in time-resolved MRA at 3.0 T

    International Nuclear Information System (INIS)

    Hadizadeh, Dariusch R.; Gieseke, Juergen; Beck, Gabriele; Geerts, Liesbeth; Kukuk, Guido M.; Bostroem, Azize; Urbach, Horst; Schild, Hans H.; Willinek, Winfried A.

    2011-01-01

    Introduction: Time-resolved contrast-enhanced magnetic resonance (MR) angiography (CEMRA) of the intracranial vasculature has proved its clinical value for the evaluation of cerebral vascular disease in cases where both flow hemodynamics and morphology are important. The purpose of this study was to evaluate a combination of view-sharing with keyhole imaging to increase spatial and temporal resolution of time-resolved CEMRA at 3.0 T. Methods: Alternating view-sharing was combined with randomly segmented k-space ordering, keyhole imaging, partial Fourier and parallel imaging (4DkvsMRA). 4DkvsMRA was evaluated using varying compression factors (80-100) resulting in spatial resolutions ranging from (1.1 x 1.1 x 1.4) to (0.96 x 0.96 x 0.95) mm 3 and temporal resolutions ranging from 586 ms/dynamic scan - 288 ms/dynamic scan in three protocols in 10 healthy volunteers and seven patients (17 subjects). DSA correlation was available in four patients with cerebral arteriovenous malformations (cAVMs) and one patient with cerebral teleangiectasia. Results: 4DkvsMRA was successfully performed in all subjects and showed clear depiction of arterial and venous phases with diagnostic image quality. At the maximum view-sharing compression factor (=100), a 'flickering' artefact was observed. Conclusion: View-sharing in keyhole imaging allows for increased spatial and temporal resolution in time-resolved MRA.

  5. View-sharing in keyhole imaging: Partially compressed central k-space acquisition in time-resolved MRA at 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Hadizadeh, Dariusch R., E-mail: Dariusch.Hadizadeh@ukb.uni-bonn.de [University of Bonn, Department of Radiology, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Gieseke, Juergen [University of Bonn, Department of Radiology, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Philips Healthcare, Best (Netherlands); Beck, Gabriele; Geerts, Liesbeth [Philips Healthcare, Best (Netherlands); Kukuk, Guido M. [University of Bonn, Department of Radiology, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Bostroem, Azize [Department of Neurosurgery, Sigmund-Freud-Strasse 25, 53127 Bonn, Deutschland (Germany); Urbach, Horst; Schild, Hans H.; Willinek, Winfried A. [University of Bonn, Department of Radiology, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany)

    2011-11-15

    Introduction: Time-resolved contrast-enhanced magnetic resonance (MR) angiography (CEMRA) of the intracranial vasculature has proved its clinical value for the evaluation of cerebral vascular disease in cases where both flow hemodynamics and morphology are important. The purpose of this study was to evaluate a combination of view-sharing with keyhole imaging to increase spatial and temporal resolution of time-resolved CEMRA at 3.0 T. Methods: Alternating view-sharing was combined with randomly segmented k-space ordering, keyhole imaging, partial Fourier and parallel imaging (4DkvsMRA). 4DkvsMRA was evaluated using varying compression factors (80-100) resulting in spatial resolutions ranging from (1.1 x 1.1 x 1.4) to (0.96 x 0.96 x 0.95) mm{sup 3} and temporal resolutions ranging from 586 ms/dynamic scan - 288 ms/dynamic scan in three protocols in 10 healthy volunteers and seven patients (17 subjects). DSA correlation was available in four patients with cerebral arteriovenous malformations (cAVMs) and one patient with cerebral teleangiectasia. Results: 4DkvsMRA was successfully performed in all subjects and showed clear depiction of arterial and venous phases with diagnostic image quality. At the maximum view-sharing compression factor (=100), a 'flickering' artefact was observed. Conclusion: View-sharing in keyhole imaging allows for increased spatial and temporal resolution in time-resolved MRA.

  6. CLIPS/Ada: An Ada-based tool for building expert systems

    Science.gov (United States)

    White, W. A.

    1990-01-01

    Clips/Ada is a production system language and a development environment. It is functionally equivalent to the CLIPS tool. CLIPS/Ada was developed in order to provide a means of incorporating expert system technology into projects where the use of the Ada language had been mandated. A secondary purpose was to glean information about the Ada language and its compilers. Specifically, whether or not the language and compilers were mature enough to support AI applications. The CLIPS/Ada tool is coded entirely in Ada and is designed to be used by Ada systems that require expert reasoning.

  7. 21 CFR 882.4190 - Clip forming/cutting instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clip forming/cutting instrument. 882.4190 Section 882.4190 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES.../cutting instrument. (a) Identification. A clip forming/cutting instrument is a device used by the...

  8. Clinical experience of titanium cerebral aneurysm clips. Evaluation of artifact of CT and MRI

    International Nuclear Information System (INIS)

    Ninomiya, Takashi; Kato, Yoko; Sano, Hirotoshi

    1996-01-01

    The titanium aneurysm clips manufactured by AESCULAP Company are expected to be useful, not only for clinical applications, but also for reducing artifacts in post-operative CT and MRI. We carried out an investigation of the behavior of the new Yasargil titanium clips in a 1.5T MR imager. The new titanium clips showed considerably smaller clip-induced MR and CT artifacts than phynox and elgiloy clips. No movement of the titanium clips was seen by introducing them to the MR imager. Subsequent to these experimental studies, we applied titanium clips to 25 cerebral aneurysms. Post-operative CT, especially helical scanning CT and MR showed minimal artifacts, leading to the conclusion that the titanium clips are better than the other types of clips for the evaluation of post-operative neuroradiological images. (author)

  9. Dose-response effects in immunizations with keyhole limpet haemocyanin and rabies vaccine: shift in some immunodeficiency states

    NARCIS (Netherlands)

    Korver, K.; Boeschoten, E. W.; Krediet, R. T.; van Steenis, G.; Schellekens, P. T.

    1987-01-01

    We investigated the primary antibody response to the antigens keyhole limpet haemocyanin (KLH) and rabies vaccine (RV). Eighty-one healthy volunteers were injected with nine doses of KLH (ranging from 10 to 2500 micrograms) and 66 volunteers with six doses of RV (ranging from 17 to 680 micrograms

  10. Remission of migraine after clipping of saccular intracranial aneurysms

    DEFF Research Database (Denmark)

    Lebedeva, E R; Busygina, A V; Kolotvinov, V S

    2015-01-01

    interview. The remission rates of migraine and tension-type headache (TTH) in these patients were compared to 92 patients from a headache center. Diagnoses were made according to the ICHD-2. RESULTS: During 1 year preceding rupture 51 patients with SIA had migraine. During the year after clipping......BACKGROUND: Unruptured saccular intracranial aneurysm (SIA) is associated with an increased prevalence of migraine, but it is unclear whether this is altered by clipping of the aneurysm. The aim of our study was to determine whether remission rate of migraine and other recurrent headaches...... was greater in patients with SIA after clipping than in controls. METHODS: We prospectively studied 87 SIA patients with migraine or other recurrent headaches. They were interviewed about headaches in the preceding year before and 1 year after clipping using a validated semi-structured neurologist conducted...

  11. Film clips and narrative text as subjective emotion elicitation techniques.

    Science.gov (United States)

    Zupan, Barbra; Babbage, Duncan R

    2017-01-01

    Film clips and narrative text are useful techniques in eliciting emotion in a laboratory setting but have not been examined side-by-side using the same methodology. This study examined the self-identification of emotions elicited by film clip and narrative text stimuli to confirm that selected stimuli appropriately target the intended emotions. Seventy participants viewed 30 film clips, and 40 additional participants read 30 narrative texts. Participants identified the emotion experienced (happy, sad, angry, fearful, neutral-six stimuli each). Eighty-five percent of participants self-identified the target emotion for at least two stimuli for all emotion categories of film clips, except angry (only one) and for all categories of narrative text, except fearful (only one). The most effective angry text was correctly identified 74% of the time. Film clips were more effective in eliciting all target emotions in participants for eliciting the correct emotion (angry), intensity rating (happy, sad), or both (fearful).

  12. Supraorbital Keyhole Microsurgical Fenestration of Symptomatic Temporal Arachnoid Cysts in Children: Advantages and Limitations.

    Science.gov (United States)

    Elkheshin, Sherif; Soliman, Ahmed

    2017-01-01

    To investigate the impact of endoscope-assisted microsurgical fenestration on temporal arachnoid cysts, and to determine the advantages and limitations of the technique. Twenty-five children with symptomatic temporal arachnoid cysts were operated via eyebrow supraorbital keyhole microsurgical fenestration targeting the medial cyst wall. Preoperative magnetic resonance imaging (MRI) of the brain was done for all patients. Preoperative clinical presentation of the patients included headache (80%), nausea & vomiting (64%), drug resistant epilepsy (52%), macrocephaly (12%) papilledema (28%), motor weakness in the form of right-sided hemiparesis (12%) and cranial nerve palsy. Postoperative complete subsidence of headache was noted in 50%, while 20% remained unchanged. Drug resistant epilepsy improved in 69% of the patients. Postoperative MRI showed initial decrease in cyst volume as early as 3 months, only in a range of 5-12% volume reduction, and the late follow-up done at 6 and 18 months continued to show further reduction reported to be significant (p CSF) collection was the most common complication (20%). Only 1 patient experienced CSF leak mandating cysto-peritoneal shunting. Conclusıon: Eyebrow supraorbital keyhole microsurgical fenestration for temporal arachnoid cysts can be performed with a fairly low risk of complications and yields a favorable improvement in clinical and neuroimaging outcomes.

  13. Current MitraClip experience, safety and feasibility in the Netherlands

    OpenAIRE

    Rahhab, Z.; Kortlandt, F.A.; Velu, J.F.; Schurer, R.A.J.; Delgado, V.; Tonino, P.; Boven, A.J. van; Branden, B.J.L. Van den; Kraaijeveld, A.O.; Voskuil, M.; Hoorntje, J.; Wely, M.H. van; Houwelingen, K. van; Bleeker, G.B.; Rensing, B.

    2017-01-01

    PURPOSE: Data on MitraClip procedural safety and efficacy in the Netherlands are scarce. We aim to provide an overview of the Dutch MitraClip experience. METHODS: We pooled anonymised demographic and procedural data of 1151 consecutive MitraClip patients, from 13 Dutch hospitals. Data was collected by product specialists in collaboration with local operators. Effect on mitral regurgitation was intra-procedurally assessed by transoesophageal echocardiography. Technical success and device succe...

  14. Comparison of Sonography versus Digital Breast Tomosynthesis to Locate Intramammary Marker Clips.

    Science.gov (United States)

    Schulz-Wendtland, R; Dankerl, P; Dilbat, G; Bani, M; Fasching, P A; Heusinger, K; Lux, M P; Loehberg, C R; Jud, S M; Rauh, C; Bayer, C M; Beckmann, M W; Wachter, D L; Uder, M; Meier-Meitinger, M; Brehm, B

    2015-01-01

    Introduction: This study aimed to compare the accuracy of sonography versus digital breast tomosynthesis to locate intramammary marker clips placed under ultrasound guidance. Patients and Methods: Fifty patients with suspicion of breast cancer (lesion diameter less than 2 cm [cT1]) had ultrasound-guided core needle biopsy with placement of a marker clip in the center of the tumor. Intramammary marker clips were subsequently located with both sonography and digital breast tomosynthesis. Results: Sonography detected no dislocation of intrammammary marker clips in 42 of 50 patients (84 %); dislocation was reported in 8 patients (16 %) with a maximum dislocation of 7 mm along the x-, y- or z-axis. Digital breast tomosynthesis showed accurate placement without dislocation of the intramammary marker clip in 48 patients (96 %); 2 patients (4 %) had a maximum clip dislocation of 3 mm along the x-, y- or z-axis (p tomosynthesis could improve the accuracy when locating intramammary marker clips compared to sonography and could, in future, be used to complement or even completely replace sonography.

  15. Adding run history to CLIPS

    Science.gov (United States)

    Tuttle, Sharon M.; Eick, Christoph F.

    1991-01-01

    To debug a C Language Integrated Production System (CLIPS) program, certain 'historical' information about a run is needed. It would be convenient for system builders to have the capability to request such information. We will discuss how historical Rete networks can be used for answering questions that help a system builder detect the cause of an error in a CLIPS program. Moreover, the cost of maintaining a historical Rete network is compared with that for a classical Rete network. We will demonstrate that the cost for assertions is only slightly higher for a historical Rete network. The cost for handling retraction could be significantly higher; however, we will show that by using special data structures that rely on hashing, it is also possible to implement retractions efficiently.

  16. A CLIPS expert system for clinical flow cytometry data analysis

    Science.gov (United States)

    Salzman, G. C.; Duque, R. E.; Braylan, R. C.; Stewart, C. C.

    1990-01-01

    An expert system is being developed using CLIPS to assist clinicians in the analysis of multivariate flow cytometry data from cancer patients. Cluster analysis is used to find subpopulations representing various cell types in multiple datasets each consisting of four to five measurements on each of 5000 cells. CLIPS facts are derived from results of the clustering. CLIPS rules are based on the expertise of Drs. Stewart, Duque, and Braylan. The rules incorporate certainty factors based on case histories.

  17. Extravasal occlusion of large vessels with titanic clips: efficiency, indications, and contraindications.

    Science.gov (United States)

    Vasilenko, Yu V; Kim, A I; Kotov, S A

    2002-11-01

    The mechanism of extravasal occlusion of blood vessels with titanic clips "Atrauclip" and "Ligaclip extra" was studied in order to reveal indications and contraindications to their use. Occlusion with the clips of both types was ineffective in vessels with a diameter of >7.0 mm. Arteritis or the presence of an intravascular occlusion facility in the vessel were also the contraindications for clip occlusion. In overcases the procedure of occlusion with titanic clips was efficient and atraumatic.

  18. Molecular clips based on propanediurea : synthesis and physical properties

    NARCIS (Netherlands)

    Jansen, Robertus Johannes

    2002-01-01

    This thesis describes the synthesis and physical properties of a series of molecular clips derived from the concave molecule propanediurea. These molecular clips are cavity-containing receptors that can bind a variety of aromatic guests. This binding is a result of hydrogen bonding and pi-pi

  19. Bayesian Recovery of Clipped OFDM Signals: A Receiver-based Approach

    KAUST Repository

    Al-Rabah, Abdullatif R.

    2013-05-01

    Recently, orthogonal frequency-division multiplexing (OFDM) has been adopted for high-speed wireless communications due to its robustness against multipath fading. However, one of the main fundamental drawbacks of OFDM systems is the high peak-to-average-power ratio (PAPR). Several techniques have been proposed for PAPR reduction. Most of these techniques require transmitter-based (pre-compensated) processing. On the other hand, receiver-based alternatives would save the power and reduce the transmitter complexity. By keeping this in mind, a possible approach is to limit the amplitude of the OFDM signal to a predetermined threshold and equivalently a sparse clipping signal is added. Then, estimating this clipping signal at the receiver to recover the original signal. In this work, we propose a Bayesian receiver-based low-complexity clipping signal recovery method for PAPR reduction. The method is able to i) effectively reduce the PAPR via simple clipping scheme at the transmitter side, ii) use Bayesian recovery algorithm to reconstruct the clipping signal at the receiver side by measuring part of subcarriers, iii) perform well in the absence of statistical information about the signal (e.g. clipping level) and the noise (e.g. noise variance), and at the same time iv is energy efficient due to its low complexity. Specifically, the proposed recovery technique is implemented in data-aided based. The data-aided method collects clipping information by measuring reliable 
data subcarriers, thus makes full use of spectrum for data transmission without the need for tone reservation. The study is extended further to discuss how to improve the recovery of the clipping signal utilizing some features of practical OFDM systems i.e., the oversampling and the presence of multiple receivers. Simulation results demonstrate the superiority of the proposed technique over other recovery algorithms. The overall objective is to show that the receiver-based Bayesian technique is highly

  20. Understanding and Applying Psychology through Use of News Clippings.

    Science.gov (United States)

    Rider, Elizabeth A.

    1992-01-01

    Discusses a student project for psychology courses in which students collect newspaper clippings that illustrate psychological concepts. Explains that the students record the source and write a brief description of the clipping, explaining how it relates to a psychological concept or theory. Includes results of student evaluations of the…

  1. Sympathetic block by metal clips may be a reversible operation

    DEFF Research Database (Denmark)

    Thomsen, Lars L; Mikkelsen, Rasmus T; Derejko, Miroslawa

    2014-01-01

    , but the question of reversibility remains controversial. Two recent experimental studies found severe histological signs of nerve damage 4-6 weeks after clip removal, but they only used conventional histopathological staining methods. METHODS: Thoracoscopic clipping of the sympathetic trunk was performed in adult...... the sympathetic chain vary tremendously. Most surgeons transect or resect the sympathetic chain, but application of a metal clip that blocks transmission of nerve impulses in the sympathetic chain is used increasingly worldwide. This approach offers potential reversibility if patients regret surgery...... suggests in theory that application of metal clips to the sympathetic chain is a reversible procedure if only the observation period is prolonged. Further studies with longer periods between application and removal as well as investigations of nerve conduction should be encouraged, because we do not know...

  2. The influence of clipping frequency on reserve carbohydrates and ...

    African Journals Online (AJOL)

    Increasing the frequency of clipping over a 12 week period resulted in decreasing root and stubble weight at the end of the 12 week period. During the regrowth period, following the clipping treatment, the aerial dry matter production was found to increase with the more lenient treatments. Keywords: weights|dry ...

  3. Suture retraction technique to prevent parent vessel obstruction following aneurysm tandem clipping.

    Science.gov (United States)

    Rayan, Tarek; Amin-Hanjani, Sepideh

    2015-08-01

    With large or giant aneurysms, the use of multiple tandem clips can be essential for complete obliteration of the aneurysm. One potential disadvantage, however, is the considerable cumulative weight of these clips, which may lead to kinking of the underlying parent vessels and obstruction of flow. The authors describe a simple technique to address this problem, guided by intraoperative blood flow measurements, in a patient with a ruptured near-giant 2.2 × 1.7-cm middle cerebral artery bifurcation aneurysm that was treated with the tandem clipping technique. A total of 11 clips were applied in a vertical stacked fashion. The cumulative weight of the clips caused kinking of the temporal M2 branch of the bifurcation with reduction of flow. A 4-0 Nurolon suture tie was applied to the hub of one of the clips and was tethered to the dura of the sphenoid ridge by a small mini-clip and reinforced by application of tissue sealant. The patient underwent intraoperative indocyanine green videoangiography as well as catheter angiography, which demonstrated complete aneurysmal obliteration and preservation of vessel branches. Postoperative angiography confirmed patency of the bifurcation vessels with mild vasospasm. The patient had a full recovery with no postoperative complications and was neurologically intact at her 6-month follow-up. The suture retraction technique allows a simple solution to parent vessel obstruction following aneurysm tandem clipping, in conjunction with the essential guidance provided by intraoperative flow measurements.

  4. A systematic review of discomfort due to toe or ear clipping in laboratory rodents

    Science.gov (United States)

    Geessink, Florentine J.; Brouwer, Michelle A. E.; Tillema, Alice; Ritskes-Hoitinga, Merel

    2017-01-01

    Toe clipping and ear clipping (also ear notching or ear punching) are frequently used methods for individual identification of laboratory rodents. These procedures potentially cause severe discomfort, which can reduce animal welfare and distort experimental results. However, no systematic summary of the evidence on this topic currently exists. We conducted a systematic review of the evidence for discomfort due to toe or ear clipping in rodents. The review methodology was pre-specified in a registered review protocol. The population, intervention, control, outcome (PICO) question was: In rodents, what is the effect of toe clipping or ear clipping, compared with no clipping or sham clipping, on welfare-related outcomes? Through a systematic search in PubMed, Embase, Web of Science and grey literature, we identified seven studies on the effect of ear clipping on animal welfare, and five such studies on toe clipping. Studies were included in the review if they contained original data from an in vivo experiment in rodents, assessing the effect of toe clipping or ear clipping on a welfare-related outcome. Case studies and studies applying unsuitable co-interventions were excluded. Study quality was appraised using an extended version of SYstematic Review Centre for Laboratory animal Experimentation (SYRCLE)’s risk of bias tool for animal studies. Study characteristics and outcome measures were highly heterogeneous, and there was an unclear or high risk of bias in all studies. We therefore present a narrative synthesis of the evidence identified. None of the studies reported a sample size calculation. Out of over 60 different outcomes, we found evidence of discomfort due to ear clipping in the form of increased respiratory volume, vocalization and blood pressure. For toe clipping, increased vocalization and decreased motor activity in pups were found, as well as long-term effects in the form of reduced grip strength and swimming ability in adults. In conclusion, there

  5. Peak reduction and clipping mitigation in OFDM by augmented compressive sensing

    KAUST Repository

    Al-Safadi, Ebrahim B.

    2012-07-01

    This work establishes the design, analysis, and fine-tuning of a peak-to-average-power-ratio (PAPR) reducing system, based on compressed sensing (CS) at the receiver of a peak-reducing sparse clipper applied to an orthogonal frequency-division multiplexing (OFDM) signal at the transmitter. By exploiting the sparsity of clipping events in the time domain relative to a predefined clipping threshold, the method depends on partially observing the frequency content of the clipping distortion over reserved tones to estimate the remaining distortion. The approach has the advantage of eliminating the computational complexity at the transmitter and reducing the overall complexity of the system compared to previous methods which incorporate pilots to cancel nonlinear distortion. Data-based augmented CS methods are also proposed that draw upon available phase and support information from data tones for enhanced estimation and cancelation of clipping noise. This enables signal recovery under more severe clipping scenarios and hence lower PAPR can be achieved compared to conventional CS techniques. © 2012 IEEE.

  6. Peak reduction and clipping mitigation in OFDM by augmented compressive sensing

    KAUST Repository

    Al-Safadi, Ebrahim B.; Al-Naffouri, Tareq Y.

    2012-01-01

    This work establishes the design, analysis, and fine-tuning of a peak-to-average-power-ratio (PAPR) reducing system, based on compressed sensing (CS) at the receiver of a peak-reducing sparse clipper applied to an orthogonal frequency-division multiplexing (OFDM) signal at the transmitter. By exploiting the sparsity of clipping events in the time domain relative to a predefined clipping threshold, the method depends on partially observing the frequency content of the clipping distortion over reserved tones to estimate the remaining distortion. The approach has the advantage of eliminating the computational complexity at the transmitter and reducing the overall complexity of the system compared to previous methods which incorporate pilots to cancel nonlinear distortion. Data-based augmented CS methods are also proposed that draw upon available phase and support information from data tones for enhanced estimation and cancelation of clipping noise. This enables signal recovery under more severe clipping scenarios and hence lower PAPR can be achieved compared to conventional CS techniques. © 2012 IEEE.

  7. Catheter Entrapment During Posterior Mitral Leaflet Pushing Maneuver for MitraClip Implantation.

    Science.gov (United States)

    Castrodeza, Javier; Amat-Santos, Ignacio J; Tobar, Javier; Varela-Falcón, Luis H

    2016-06-01

    MitraClip (Abbott Vascular) therapy has been reported to be an effective procedure for mitral regurgitation, especially in high-risk patients. Recently, the novel pushing maneuver technique has been described for approaching restricted and short posterior leaflets with a pigtail catheter in order to facilitate grasping of the clip. However, complications or unexpected situations may occur. We report the case of an 84-year-old patient who underwent MitraClip implantation wherein the pushing maneuver was complicated by the clip accidentally gripping the pigtail catheter along with the two leaflets.

  8. Preoperative simulation for the planning of microsurgical clipping of intracranial aneurysms.

    Science.gov (United States)

    Marinho, Paulo; Vermandel, Maximilien; Bourgeois, Philippe; Lejeune, Jean-Paul; Mordon, Serge; Thines, Laurent

    2014-12-01

    The safety and success of intracranial aneurysm (IA) surgery could be improved through the dedicated application of simulation covering the procedure from the 3-dimensional (3D) description of the surgical scene to the visual representation of the clip application. We aimed in this study to validate the technical feasibility and clinical relevance of such a protocol. All patients preoperatively underwent 3D magnetic resonance imaging and 3D computed tomography angiography to build 3D reconstructions of the brain, cerebral arteries, and surrounding cranial bone. These 3D models were segmented and merged using Osirix, a DICOM image processing application. This provided the surgical scene that was subsequently imported into Blender, a modeling platform for 3D animation. Digitized clips and appliers could then be manipulated in the virtual operative environment, allowing the visual simulation of clipping. This simulation protocol was assessed in a series of 10 IAs by 2 neurosurgeons. The protocol was feasible in all patients. The visual similarity between the surgical scene and the operative view was excellent in 100% of the cases, and the identification of the vascular structures was accurate in 90% of the cases. The neurosurgeons found the simulation helpful for planning the surgical approach (ie, the bone flap, cisternal opening, and arterial tree exposure) in 100% of the cases. The correct number of final clip(s) needed was predicted from the simulation in 90% of the cases. The preoperatively expected characteristics of the optimal clip(s) (ie, their number, shape, size, and orientation) were validated during surgery in 80% of the cases. This study confirmed that visual simulation of IA clipping based on the processing of high-resolution 3D imaging can be effective. This is a new and important step toward the development of a more sophisticated integrated simulation platform dedicated to cerebrovascular surgery.

  9. Bayesian Recovery of Clipped OFDM Signals: A Receiver-based Approach

    KAUST Repository

    Al-Rabah, Abdullatif R.

    2013-01-01

    recovery algorithm to reconstruct the clipping signal at the receiver side by measuring part of subcarriers, iii) perform well in the absence of statistical information about the signal (e.g. clipping level) and the noise (e.g. noise variance

  10. Effective capacity of multiple antenna channels: Correlation and keyhole

    KAUST Repository

    Zhong, Caijun

    2012-01-01

    In this study, the authors derive the effective capacity limits for multiple antenna channels which quantify the maximum achievable rate with consideration of link-layer delay-bound violation probability. Both correlated multiple-input single-output and multiple-input multiple-output keyhole channels are studied. Based on the closed-form exact expressions for the effective capacity of both channels, the authors look into the asymptotic high and low signal-to-noise ratio regimes, and derive simple expressions to gain more insights. The impact of spatial correlation on effective capacity is also characterised with the aid of a majorisation theory result. It is revealed that antenna correlation reduces the effective capacity of the channels and a stringent quality-of-service requirement causes a severe reduction in the effective capacity but can be alleviated by increasing the number of antennas. © 2012 The Institution of Engineering and Technology.

  11. Equation-Method for correcting clipping errors in OFDM signals.

    Science.gov (United States)

    Bibi, Nargis; Kleerekoper, Anthony; Muhammad, Nazeer; Cheetham, Barry

    2016-01-01

    Orthogonal frequency division multiplexing (OFDM) is the digital modulation technique used by 4G and many other wireless communication systems. OFDM signals have significant amplitude fluctuations resulting in high peak to average power ratios which can make an OFDM transmitter susceptible to non-linear distortion produced by its high power amplifiers (HPA). A simple and popular solution to this problem is to clip the peaks before an OFDM signal is applied to the HPA but this causes in-band distortion and introduces bit-errors at the receiver. In this paper we discuss a novel technique, which we call the Equation-Method, for correcting these errors. The Equation-Method uses the Fast Fourier Transform to create a set of simultaneous equations which, when solved, return the amplitudes of the peaks before they were clipped. We show analytically and through simulations that this method can, correct all clipping errors over a wide range of clipping thresholds. We show that numerical instability can be avoided and new techniques are needed to enable the receiver to differentiate between correctly and incorrectly received frequency-domain constellation symbols.

  12. Modeling Timbre Similarity of Short Music Clips.

    Science.gov (United States)

    Siedenburg, Kai; Müllensiefen, Daniel

    2017-01-01

    There is evidence from a number of recent studies that most listeners are able to extract information related to song identity, emotion, or genre from music excerpts with durations in the range of tenths of seconds. Because of these very short durations, timbre as a multifaceted auditory attribute appears as a plausible candidate for the type of features that listeners make use of when processing short music excerpts. However, the importance of timbre in listening tasks that involve short excerpts has not yet been demonstrated empirically. Hence, the goal of this study was to develop a method that allows to explore to what degree similarity judgments of short music clips can be modeled with low-level acoustic features related to timbre. We utilized the similarity data from two large samples of participants: Sample I was obtained via an online survey, used 16 clips of 400 ms length, and contained responses of 137,339 participants. Sample II was collected in a lab environment, used 16 clips of 800 ms length, and contained responses from 648 participants. Our model used two sets of audio features which included commonly used timbre descriptors and the well-known Mel-frequency cepstral coefficients as well as their temporal derivates. In order to predict pairwise similarities, the resulting distances between clips in terms of their audio features were used as predictor variables with partial least-squares regression. We found that a sparse selection of three to seven features from both descriptor sets-mainly encoding the coarse shape of the spectrum as well as spectrotemporal variability-best predicted similarities across the two sets of sounds. Notably, the inclusion of non-acoustic predictors of musical genre and record release date allowed much better generalization performance and explained up to 50% of shared variance ( R 2 ) between observations and model predictions. Overall, the results of this study empirically demonstrate that both acoustic features related

  13. Effects of Japanese beetle (Coleoptera: Scarabaeidae) and silk clipping in field corn.

    Science.gov (United States)

    Steckel, Sandy; Stewart, S D; Tindall, K V

    2013-10-01

    Japanese beetle (Popillia japonica Newman) is an emerging silk-feeding insect found in fields in the lower Corn Belt and Midsouthern United States. Studies were conducted in 2010 and 2011 to evaluate how silk clipping in corn affects pollination and yield parameters. Manually clipping silks once daily had modest effects on yield parameters. Sustained clipping by either manually clipping silks three times per day or by caging Japanese beetles onto ears affected total kernel weight if it occurred during early silking (R1 growth stage). Manually clipping silks three times per day for the first 5 d of silking affected the number of kernels per ear, total kernel weight, and the weight of individual kernels. Caged beetles fed on silks and, depending on the number of beetles caged per ear, reduced the number of kernels per ear. Caging eight beetles per ear significantly reduced total kernel weight compared with noninfested ears. Drought stress before anthesis appeared to magnify the impact of silk clipping by Japanese beetles. There was evidence of some compensation for reduced pollination by increasing the size of pollinated kernels within the ear. Our results showed that it requires sustained silk clipping during the first week of silking to have substantial impacts on pollination and yield parameters, at least under good growing conditions. Some states recommend treating for Japanese beetle when three Japanese beetles per ear are found, silks are clipped to < 13 mm, and pollination is < 50% complete, and that recommendation appears to be adequate.

  14. Hemodynamic response during aneurysm clipping surgery among experienced neurosurgeons.

    Science.gov (United States)

    Bunevicius, Adomas; Bilskiene, Diana; Macas, Andrius; Tamasauskas, Arimantas

    2016-02-01

    Neurosurgery is a challenging field associated with high levels of mental stress. The goal of this study was to investigate the hemodynamic response of experienced neurosurgeons during aneurysm clipping surgery and to evaluate whether neurosurgeons' hemodynamic responses are associated with patients' clinical statuses. Four vascular neurosurgeons (all male; mean age 51 ± 10 years; post-residency experience ≥7 years) were studied during 42 aneurysm clipping procedures. Blood pressure (BP) and heart rate (HR) were assessed at rest and during seven phases of surgery: before the skin incision, after craniotomy, after dural opening, after aneurysm neck dissection, after aneurysm clipping, after dural closure and after skin closure. HR and BP were significantly greater during surgery relative to the rest situation (p ≤ 0.03). There was a statistically significant increase in neurosurgeons' HR (F [6, 41] = 10.88, p neurosurgeon experience, the difference in BP as a function of aneurysm rupture was not significant (p > 0.08). Aneurysm location, intraoperative aneurysm rupture, admission WFNS score, admission Glasgow Coma Scale scores and Fisher grade were not associated with neurosurgeons' intraoperative HR and BP (all p > 0.07). Aneurysm clipping surgery is associated with significant hemodynamic system activation among experienced neurosurgeons. The greatest HR and BP were after aneurysm neck dissection and clipping. Aneurysm location and patient clinical status were not associated with intraoperative changes of neurosurgeons' HR and BP.

  15. An anthropomorphic phantom study of visualisation of surgical clips for partial breast irradiation (PBI) setup verification

    International Nuclear Information System (INIS)

    Thomas, Carys W.; Nichol, Alan M.; Park, Julie E.; Hui, Jason F.; Giddings, Alison A.; Grahame, Sheri; Otto, Karl

    2009-01-01

    Surgical clips were investigated for partial breast image-guided radiotherapy (IGRT). Small titanium clips were insufficiently well visualised. Medium tantalum clips were best for megavoltage IGRT and small tantalum clips were best for floor mounted kilovoltage IGRT (ExacTrac TM ). Both small tantalum and medium titanium clips were suitable for isocentric kilovoltage IGRT

  16. An anthropomorphic phantom study of visualisation of surgical clips for partial breast irradiation (PBI) setup verification.

    Science.gov (United States)

    Thomas, Carys W; Nichol, Alan M; Park, Julie E; Hui, Jason F; Giddings, Alison A; Grahame, Sheri; Otto, Karl

    2009-01-01

    Surgical clips were investigated for partial breast image-guided radiotherapy (IGRT). Small titanium clips were insufficiently well visualised. Medium tantalum clips were best for megavoltage IGRT and small tantalum clips were best for floor mounted kilovoltage IGRT (ExacTrac). Both small tantalum and medium titanium clips were suitable for isocentric kilovoltage IGRT.

  17. Como o clipping pode auxiliar o dermatologista How the Nail clipping helps the dermatologist

    Directory of Open Access Journals (Sweden)

    José Fillus Neto

    2009-04-01

    Full Text Available Alterações ungueais são queixas muito frequentes nos consultórios dermatológicos. Onicomicoses representam cerca de 50% das onicopatias, daí a importância de se estabelecer o diagnóstico correto antes de se iniciar o tratamento. Neste artigo, relataremos a utilidade de um exame que é de fácil execução pelo clínico, de baixo custo e sensível: esse exame consiste na análise histopatológica da queratina ungueal distal, atualmente já consagrado com o termo clipping.Onycodystrophies are common problems in dermatologic practice. About 50% of dystrophic nails have a fungal cause, so it is very important to establish a correct diagnosis before treatment. In this article we relate the usefulness of an easydoing exam, free from pain, cheap and sensible. This exam is the histopathology of the nail keratin or nail clipping.

  18. Definition of postlumpectomy tumor bed for radiotherapy boost field planning: CT versus surgical clips

    International Nuclear Information System (INIS)

    Goldberg, Hadassah; Prosnitz, Robert G.; Olson, John A.; Marks, Lawrence B.

    2005-01-01

    Purpose: To compare the location and extent of the tumor bed as defined by surgical clips and computed tomography (CT) scans, after lumpectomy, for electron boost planning as part of breast radiotherapy. Methods and Materials: Planning CT images of 31 operated breasts in 30 patients who underwent lumpectomy were reviewed. One or more clips were placed in the lumpectomy cavity. Serial CT images were used to measure the depth and transverse and longitudinal dimensions. The area and geometric center of the tumor bed were defined by the clips and CT. Results: The CT and clip measurements were identical for the maximal tumor depth in 27 of 30 patients. The CT bed extended beyond the clips by 0-7 mm medially in the transverse/longitudinal extent (multiclip patients). The median distance between the geometric centers in the coronal plane for the tumor bed center was larger for patients with single clips than for those with multiple clips (p 2 . The CT bed was more readily visible in patients with a shorter interval between surgery and radiotherapy. Conclusion: The maximal depth of the tumor bed was similar using the two methods. The extent and centers of the clip-and CT-determined beds differed significantly. This may indicate an underestimation of the tumor bed as defined by clips only and justifies integration of CT information in boost field planning

  19. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (UNIX VERSION)

    Science.gov (United States)

    Donnell, B.

    1994-01-01

    CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with

  20. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (MACINTOSH VERSION)

    Science.gov (United States)

    Riley, G.

    1994-01-01

    CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with

  1. Virtual Cerebral Aneurysm Clipping with Real-Time Haptic Force Feedback in Neurosurgical Education.

    Science.gov (United States)

    Gmeiner, Matthias; Dirnberger, Johannes; Fenz, Wolfgang; Gollwitzer, Maria; Wurm, Gabriele; Trenkler, Johannes; Gruber, Andreas

    2018-04-01

    Realistic, safe, and efficient modalities for simulation-based training are highly warranted to enhance the quality of surgical education, and they should be incorporated in resident training. The aim of this study was to develop a patient-specific virtual cerebral aneurysm-clipping simulator with haptic force feedback and real-time deformation of the aneurysm and vessels. A prototype simulator was developed from 2012 to 2016. Evaluation of virtual clipping by blood flow simulation was integrated in this software, and the prototype was evaluated by 18 neurosurgeons. In 4 patients with different medial cerebral artery aneurysms, virtual clipping was performed after real-life surgery, and surgical results were compared regarding clip application, surgical trajectory, and blood flow. After head positioning and craniotomy, bimanual virtual aneurysm clipping with an original forceps was performed. Blood flow simulation demonstrated residual aneurysm filling or branch stenosis. The simulator improved anatomic understanding for 89% of neurosurgeons. Simulation of head positioning and craniotomy was considered realistic by 89% and 94% of users, respectively. Most participants agreed that this simulator should be integrated into neurosurgical education (94%). Our illustrative cases demonstrated that virtual aneurysm surgery was possible using the same trajectory as in real-life cases. Both virtual clipping and blood flow simulation were realistic in broad-based but not calcified aneurysms. Virtual clipping of a calcified aneurysm could be performed using the same surgical trajectory, but not the same clip type. We have successfully developed a virtual aneurysm-clipping simulator. Next, we will prospectively evaluate this device for surgical procedure planning and education. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Training model for cerebral aneurysm clipping

    Directory of Open Access Journals (Sweden)

    Hiroshi Tenjin, M.D., Ph.D.

    2017-12-01

    Full Text Available Clipping of cerebral aneurysms is still an important skill in neurosurgery. We have made a training model for the clipping of cerebral aneurysms. The concepts for the model were 1: training model for beginners, 2: three dimensional manipulation using an operating microscope, 3: the aneurysm model is to be perfused by simulated blood causing premature rupture. The correct relationship between each tissue, and softness of the brain and vessels were characteristics of the model. The skull, brain, arteries, and veins were made using a 3D printer with data from DICOM. The brain and vessels were made from polyvinyl alcohol (PVA. One training course was held and this model was useful for training of cerebral aneurysm surgery for young neurosurgeons.

  3. Successful Removal of Football Helmet Face-Mask Clips After 1 Season of Use

    Science.gov (United States)

    Scibek, Jason S.; Gatti, Joseph M.; McKenzie, Jennifer I.

    2012-01-01

    Context Whereas many researchers have assessed the ability to remove loop straps in traditional face-mask attachment systems after at least 1 season of use, research in which the effectiveness of the Riddell Quick Release (QR) Face Guard Attachment System clip after 1 season has been assessed is limited. Objective To examine the success rate of removing the QR clips after 1 season of use at the Football Championship Subdivision level. We hypothesized that 1 season of use would negatively affect the removal rate of the QR clip but repeated clip-removal trials would improve the removal rate. Design Retrospective, quasi-experimental design. Setting Controlled laboratory study. Patients or Other Participants Sixty-three football helmets from a National Collegiate Athletic Association Division I university located in western Pennsylvania used during the 2008 season were tested. Intervention(s) Three certified athletic trainers (2 men, 1 woman; age = 31.3 ± 3.06 years, time certified = 9.42 ± 2.65 years) attempted to remove the QR clips from each helmet with the tool provided by the manufacturer. Helmets then were reassembled to allow each athletic trainer to attempt clip removal. Main Outcome Measure(s) The dependent variables were total left clips removed (TCR-L), total right clips removed (TCR-R), and total clips removed (TCR). Success rate of clip removal (SRCR) also was assessed. Results Percentages for TCR-L, TCR-R, and TCR were 100% (189 of 189), 96.30% (182 of 189), and 98.15% (371 of 378), respectively. A paired-samples t test revealed a difference between TCR-R and TCR-L (t188 = −2.689, P = .008, μd = 0.037, 95% confidence interval [CI] = −0.064, −0.010). The percentage for SRCR was 96.30% (n = 182), whereas SRCR percentages for trials 1, 2, and 3 were 95.24% (n = 60), 98.41% (n = 62), and 95.24% (n = 60), respectively, and did not represent a difference (F2,186 = 0.588, P = .56, 95% CI = 0.94, 0.99). Conclusions Our results indicated favorable and

  4. Multichannel infinite clipping as a form of sampling of speech signals

    International Nuclear Information System (INIS)

    Guidarelli, G.

    1985-01-01

    A remarkable improvement of both intelligibility and naturalness of infinitely clipped speech can be achieved by means of a multichannel system in which the speech signal is splitted into several band-pass channels before the clipping and successively reconstructed by summing up the clipped outputs of each channel. A possible explanation of such an improvement is given, founded on the so-called zero-based representation of band limited signals where the zero-crossings sequence is considered as a set of samples of the signal

  5. Delay line clipping in a scintillation camera system

    International Nuclear Information System (INIS)

    Hatch, K.F.

    1979-01-01

    The present invention provides a novel base line restoring circuit and a novel delay line clipping circuit in a scintillation camera system. Single and double delay line clipped signal waveforms are generated for increasing the operational frequency and fidelity of data detection of the camera system by base line distortion such as undershooting, overshooting, and capacitive build-up. The camera system includes a set of photomultiplier tubes and associated amplifiers which generate sequences of pulses. These pulses are pulse-height analyzed for detecting a scintillation having an energy level which falls within a predetermined energy range. Data pulses are combined to provide coordinates and energy of photopeak events. The amplifiers are biassed out of saturation over all ranges of pulse energy level and count rate. Single delay line clipping circuitry is provided for narrowing the pulse width of the decaying electrical data pulses which increase operating speed without the occurrence of data loss. (JTA)

  6. Assessing arsenic and selenium in a single nail clipping using portable X-ray fluorescence

    International Nuclear Information System (INIS)

    Fleming, David E.B.; Nader, Michel N.; Foran, Kelly A.; Groskopf, Craig; Reno, Michael C.; Ware, Chris S.; Tehrani, Mina; Guimarães, Diana; Parsons, Patrick J.

    2017-01-01

    The feasibility of measuring arsenic and selenium contents in a single nail clipping was investigated using a small-focus portable X-ray fluorescence (XRF) instrument with monochromatic excitation beams. Nail clipping phantoms supplemented with arsenic and selenium to produce materials with 0, 5, 10, 15, and 20 µg/g were used for calibration purposes. In total, 10 different clippings were analyzed at two different measurement positions. Energy spectra were fit with detection peaks for arsenic K_α, selenium K_α, arsenic K_β, selenium K_β, and bromine K_α characteristic X-rays. Data analysis was performed under two distinct conditions of fitting constraint. Calibration lines were established from the amplitude of each of the arsenic and selenium peaks as a function of the elemental contents in the clippings. The slopes of the four calibration lines were consistent between the two conditions of analysis. The calculated minimum detection limit (MDL) of the method, when considering the K_α peak only, ranged from 0.210±0.002 µg/g selenium under one condition of analysis to 0.777±0.009 µg/g selenium under another. Compared with previous portable XRF nail clipping studies, MDLs were substantially improved for both arsenic and selenium. The new measurement technique had the additional benefits of being short in duration (~3 min) and requiring only a single nail clipping. The mass of the individual clipping used did not appear to play a major role in signal strength, but positioning of the clipping is important. - Highlights: • Portable X-ray fluorescence was used to assess As and Se in nail clipping phantoms. • Calibration lines were consistent between two different conditions of data analysis. • This new XRF approach was sensitive and required only a single nail clipping.

  7. Low Proteolytic Clipping of Histone H3 in Cervical Cancer

    Science.gov (United States)

    Sandoval-Basilio, Jorge; Serafín-Higuera, Nicolás; Reyes-Hernandez, Octavio D.; Serafín-Higuera, Idanya; Leija-Montoya, Gabriela; Blanco-Morales, Magali; Sierra-Martínez, Monica; Ramos-Mondragon, Roberto; García, Silvia; López-Hernández, Luz Berenice; Yocupicio-Monroy, Martha; Alcaraz-Estrada, Sofia L.

    2016-01-01

    Chromatin in cervical cancer (CC) undergoes chemical and structural changes that alter the expression pattern of genes. Recently, a potential mechanism, which regulates gene expression at transcriptional levels is the proteolytic clipping of histone H3. However, until now this process in CC has not been reported. Using HeLa cells as a model of CC and human samples from patients with CC, we identify that the H3 cleavage was lower in CC compared with control tissue. Additionally, the histone H3 clipping was performed by serine and aspartyl proteases in HeLa cells. These results suggest that histone H3 clipping operates as part of post-translational modification system in CC. PMID:27698925

  8. Structural changes in the human vas deferens after tantalum clip occlusion and conventional vasectomy.

    Science.gov (United States)

    Kothari, L K; Gupta, A S

    1978-02-01

    In 15 human subjects, the vasa deferentia were occluded by applying two tantalum clips on one side and by conventional vasectomy with silk ligatures on the other. After 2 weeks, the occluded segments were recovered for histopathologic examination of serial sections. Obstructing the seminal tract did not, as such, produce any significant change in the vas: the distal and proximal segments appeared to be essentially similar and normal. At the actual site of occlusion, however, tantalum clips produced marked flattening of the tube, complete loss of lining epithelium, distortion of the muscular lamellae, and areas of hemorrhage. The lumen was converted into a narrow slit. Under the ligatures, the damage was largely confined to denudation of the mucosal epithelium. The mucosa of the intersegment left unexcised between two clips showed hyalinization, invasion by macrophages, and degeneration of the epithelium. The changes under the clips suggest that, although clip occlusion may offer several advantages, sterility cannot be reversed merely by removing the clips. The mechanisms of these changes, different in the case of clips and ligatures, are discussed and some possible long-term consequences are considered.

  9. Assessment of invasiveness of the Orange Keyhole Sponge, Mycale Armata, in Kaneohe Bay Oahu, Hawaii, based on surveys 2004-2005 (NODC Accession 0002602)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Orange Keyhole Sponge, Mycale armata Thiele, was unknown in Hawaii prior to 1996. First reported in Pearl Harbor, it now occurs in virtually every commercial...

  10. Assessment of Invasiveness of the Orange Keyhole Sponge Mycale Armata in Kaneohe Bay, Oahu, Hawaii Based on Surveys 2004-2005 (NODC Accession 0002602)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Orange Keyhole Sponge, Mycale armata Thiele, was unknown in Hawaii prior to 1996. First reported in Pearl Harbor, it now occurs in virtually every commercial...

  11. Sex Differences in Emotional Evaluation of Film Clips: Interaction with Five High Arousal Emotional Categories

    Science.gov (United States)

    Maffei, Antonio; Vencato, Valentina; Angrilli, Alessandro

    2015-01-01

    The present study aimed to investigate gender differences in the emotional evaluation of 18 film clips divided into six categories: Erotic, Scenery, Neutral, Sadness, Compassion, and Fear. 41 female and 40 male students rated all clips for valence-pleasantness, arousal, level of elicited distress, anxiety, jittery feelings, excitation, and embarrassment. Analysis of positive films revealed higher levels of arousal, pleasantness, and excitation to the Scenery clips in both genders, but lower pleasantness and greater embarrassment in women compared to men to Erotic clips. Concerning unpleasant stimuli, unlike men, women reported more unpleasantness to the Compassion, Sadness, and Fear compared to the Neutral clips and rated them also as more arousing than did men. They further differentiated the films by perceiving greater arousal to Fear than to Compassion clips. Women rated the Sadness and Fear clips with greater Distress and Jittery feelings than men did. Correlation analysis between arousal and the other emotional scales revealed that, although men looked less aroused than women to all unpleasant clips, they also showed a larger variance in their emotional responses as indicated by the high number of correlations and their relatively greater extent, an outcome pointing to a masked larger sensitivity of part of male sample to emotional clips. We propose a new perspective in which gender difference in emotional responses can be better evidenced by means of film clips selected and clustered in more homogeneous categories, controlled for arousal levels, as well as evaluated through a number of emotion focused adjectives. PMID:26717488

  12. Sex Differences in Emotional Evaluation of Film Clips: Interaction with Five High Arousal Emotional Categories.

    Directory of Open Access Journals (Sweden)

    Antonio Maffei

    Full Text Available The present study aimed to investigate gender differences in the emotional evaluation of 18 film clips divided into six categories: Erotic, Scenery, Neutral, Sadness, Compassion, and Fear. 41 female and 40 male students rated all clips for valence-pleasantness, arousal, level of elicited distress, anxiety, jittery feelings, excitation, and embarrassment. Analysis of positive films revealed higher levels of arousal, pleasantness, and excitation to the Scenery clips in both genders, but lower pleasantness and greater embarrassment in women compared to men to Erotic clips. Concerning unpleasant stimuli, unlike men, women reported more unpleasantness to the Compassion, Sadness, and Fear compared to the Neutral clips and rated them also as more arousing than did men. They further differentiated the films by perceiving greater arousal to Fear than to Compassion clips. Women rated the Sadness and Fear clips with greater Distress and Jittery feelings than men did. Correlation analysis between arousal and the other emotional scales revealed that, although men looked less aroused than women to all unpleasant clips, they also showed a larger variance in their emotional responses as indicated by the high number of correlations and their relatively greater extent, an outcome pointing to a masked larger sensitivity of part of male sample to emotional clips. We propose a new perspective in which gender difference in emotional responses can be better evidenced by means of film clips selected and clustered in more homogeneous categories, controlled for arousal levels, as well as evaluated through a number of emotion focused adjectives.

  13. Pull-off characteristics of double-shanked compared to single-shanked ligation clips: an animal study

    Directory of Open Access Journals (Sweden)

    Schenk Martin

    2016-09-01

    Full Text Available The use of surgical ligation clips is considered as the gold standard for the closure of vessels, particularly in laparoscopic surgery. The safety of clips is mainly achieved by the deep indentation of the metal bar with a high retention force. A novel double-shanked (DS titanium clip was compared to two single-shanked clips with respect to axial and radial pull-off forces.

  14. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (IBM PC VERSION)

    Science.gov (United States)

    Donnell, B.

    1994-01-01

    CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with

  15. It is time for a better clip applier - 3 mm, percutaneous, non-crushing and locking.

    Science.gov (United States)

    Yuval, Jonathan B; Weiss, Daniel J; Paz, Adrian; Bachar, Yehuda; Brodie, Ronit; Shapira, Yinon; Mintz, Yoav

    2017-10-06

    Since the advent of laparoscopy there have been attempts to minimize abdominal wall incisions. For this purpose smaller instruments have been produced. Our aim was to develop the first 3 mm percutaneous clip applier and to make it better than the standard clips of today. The ClipTip clip is made of Nitinol and has a crocodile shaped jaws, which when apposed effectively seal vessels. The shaft operates as a retractable needle permitting percutaneous insertion. Closing, reopening and reclosing is possible. The physical properties of the device were compared to three commercially available clip appliers. Surgeries were performed on porcine animals by experienced surgeons. In comparison to available clips, the superiority of the ClipTip is a combination of wide effective length alongside the ability to withstand strong forces. In live animal studies the Cliptip was inserted into the peritoneal cavity without any injuries. Vessels were ligated successfully and no clip dislodgement or leakage occurred. We developed the next generation clip applier with better properties. Advantages include its length, the needleoscopic caliber, non-crushing effect, locking mechanism and wide aperture. The device has performed safely and effectively in pre-clinical tests. Further studies are planned in humans.

  16. Inducing negative affect using film clips with general and eating disorder-related content.

    Science.gov (United States)

    Koushiou, Maria; Nicolaou, Kalia; Karekla, Maria

    2018-02-09

    The aim of the present study was to select appropriate film clips with a general vs. eating disorder (ED)-related content to induce negative affect. More specifically, the study examined the subjective emotional experience (valence, arousal, anxiety, induction of somatic symptoms, and ability to control reactions during film clips) of Greek-Cypriot university students (N = 79) in response to three types of film clips: general unpleasant, ED-specific unpleasant, and emotionally neutral. In addition, the study aimed to compare the emotional reactions to the aforementioned clips between two groups of participants differing on their risk for ED (high vs. low). Preliminary results indicate the clips with general content ("The Champ") and with ED-specific content ("Binge eating") that are most effective in inducing negative affect and differentiating between risk groups. These clips provide an effective method for emotion induction that can be used for assessing the emotional experience of individuals with ED symptoms, since their emotional experience is significantly implicated in the development and maintenance of their symptoms (Merwin, Clin Psychol Sci Pract 18(3):208-214, 2011).Level of evidence No level of evidence, Experimental Study.

  17. SOCIOLINGUISTIC IMPORT OF NAME-CLIPPING AMONG ...

    African Journals Online (AJOL)

    NGOZI

    2013-02-27

    Feb 27, 2013 ... experiences which, most of the times, encompass cultural and philosophical ... The art of name clipping goes way back in language history ... describes Akan names as “iconic representation of complete social variables that ...

  18. Object oriented development of engineering software using CLIPS

    Science.gov (United States)

    Yoon, C. John

    1991-01-01

    Engineering applications involve numeric complexity and manipulations of a large amount of data. Traditionally, numeric computation has been the concern in developing an engineering software. As engineering application software became larger and more complex, management of resources such as data, rather than the numeric complexity, has become the major software design problem. Object oriented design and implementation methodologies can improve the reliability, flexibility, and maintainability of the resulting software; however, some tasks are better solved with the traditional procedural paradigm. The C Language Integrated Production System (CLIPS), with deffunction and defgeneric constructs, supports the procedural paradigm. The natural blending of object oriented and procedural paradigms has been cited as the reason for the popularity of the C++ language. The CLIPS Object Oriented Language's (COOL) object oriented features are more versatile than C++'s. A software design methodology based on object oriented and procedural approaches appropriate for engineering software, and to be implemented in CLIPS was outlined. A method for sensor placement for Space Station Freedom is being implemented in COOL as a sample problem.

  19. Optimizing assessment of sexual arousal in postmenopausal women using erotic film clips.

    Science.gov (United States)

    Ramos Alarcon, Lauren G; Dai, Jing; Collins, Karen; Perez, Mindy; Woodard, Terri; Diamond, Michael P

    2017-10-01

    This study sought to assess sexual arousal in a subgroup of women by identifying erotic film clips that would be most mentally appealing and physically arousing to postmenopausal women. By measuring levels of mental appeal and self-reported physical arousal using a bidirectional scale, we aimed to elucidate the clips that would best be utilized for sexual health research in the postmenopausal or over 50-year-old subpopulation. Our results showed that postmenopausal women did not rate clips with older versus younger actors differently (p>0.05). The mean mental and mean physical scores were significantly correlated for both premenopausal subject ratings (r=0.69, perotic film clips; this knowledge is relevant for design of future sexual function research. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Establishment of an easy Ic measurement method of HTS superconducting tapes using clipped voltage taps

    International Nuclear Information System (INIS)

    Shin, Hyung Seop; Nisay, Arman; Dedicatoria, Marlon; Sim, Ki Deok

    2014-01-01

    The critical current, I c of HTS superconducting tapes can be measured by transport or contactless method. Practically, the transport method using the four-probe method is the most common. In this study, a simple test procedure by clipping the voltage lead taps have been introduced instead of soldering which reduces time and effort and thereby achieving a much faster measurement of I c . When using a pair of iron clips, I c value decreased as compared with the measured one by standard method using soldered voltage taps and varies with the width of the clipped specimen part. However, when using a pure Cu clip, both by clipping and by soldering voltage taps give a comparable result and I c measured are equal and close to the samples specification. As a result, material to be used as voltage clip should be considered and should not influence the potential voltage between the leads during I c measurement. Furthermore, the simulation result of magnetic flux during I c measurement test showed that the decrease of I c observed in the experiment is due to the magnetic flux density, By produced at the clipped part of the sample by the operating current with iron clips attached to the sample.

  1. HUMORAL IMMUNE-RESPONSE TO 2,4-DINITROPHENYL KEYHOLE LIMPET HEMOCYANIN IN ANTIGEN-FREE, GERM-FREE AND CONVENTIONAL BALB/C MICE

    NARCIS (Netherlands)

    BOS, NA; PLOPLIS, VA

    The B cell immune response to 2,4-dinitrophenyl (DNP) keyhole limpet hemocyanin was compared in antigen-free, germ-free and conventional BALB/c mice. The numbers of total and of DNP-specific IgM-, IgG- and IgA-secreting cells in the spleen were determined by enzyme-linked immunosorbent plaque assays

  2. Portable x-ray fluorescence for the analysis of chromium in nail and nail clippings

    International Nuclear Information System (INIS)

    Fleming, David E.B.; Ware, Chris S.

    2017-01-01

    Assessment of chromium content in human nail or nail clippings could serve as an effective biomarker of chromium status. The feasibility of a new portable x-ray fluorescence (XRF) approach to chromium measurement was investigated through analysis of nail and nail clipping phantoms. Five measurements of 180 s (real time) duration were first performed on six whole nail phantoms having chromium concentrations of 0, 2, 5, 10, 15, and 20 µg/g. Using nail clippers, these phantoms were then converted to nail clippings, and assembled into different mass groups of 20, 40, 60, 80, and 100 mg for additional measurements. The amplitude of the chromium Kα characteristic x-ray energy peak was examined as a function of phantom concentration for all measurement conditions to create a series of calibration lines. The minimum detection limit (MDL) for chromium was also calculated for each case. The chromium MDL determined from the whole nail intact phantoms was 0.88±0.03 µg/g. For the clipping phantoms, the MDL ranged from 1.2 to 3.3 µg/g, depending on the mass group analyzed. For the 40 mg clipping group, the MDL was 1.2±0.1 µg/g, and higher mass collections did not improve upon this result. This MDL is comparable to chromium concentration levels seen in various studies involving human nail clippings. Further improvements to the portable XRF technique would be required to detect chromium levels expected from the lower end of a typical population. - Highlights: • Portable x-ray fluorescence (XRF) was explored as a technique to assess levels of chromium in human nails or nail clippings. • Results were found to depend on the mass of clipping sample provided. • Minimum detection limits for chromium were similar to concentration levels found in previous studies of human nail clippings.

  3. The Use of Film Clips in a Viewing Time Task of Sexual Interests.

    Science.gov (United States)

    Lalumière, Martin L; Babchishin, Kelly M; Ebsworth, Megan

    2018-04-01

    Viewing time tasks using still pictures to assess age and gender sexual interests have been well validated and are commonly used. The use of film clips in a viewing time task would open up interesting possibilities for the study of sexual interest toward sexual targets or activities that are not easily captured in still pictures. We examined the validity of a viewing time task using film clips to assess sexual interest toward male and female targets, in a sample of 52 young adults. Film clips produced longer viewing times than still pictures. For both men and women, the indices derived from the film viewing time task were able to distinguish individuals who identified as homosexual (14 men, 8 women) from those who identified as heterosexual (15 men, 15 women), and provided comparable group differentiation as indices derived from a viewing time task using still pictures. Men's viewing times were more gender-specific than those of women. Viewing times to film clips were correlated with participants' ratings of sexual appeal of the same clips, and with viewing times to pictures. The results support the feasibility of a viewing time measure of sexual interest that utilizes film clips and, thus, expand the types of sexual interests that could be investigated (e.g., sadism, biastophilia).

  4. The OTSC®-clip in revisional endoscopy against weight gain after bariatric gastric bypass surgery.

    Science.gov (United States)

    Heylen, Alex Marie Florent; Jacobs, Anja; Lybeer, Monika; Prosst, Ruediger L

    2011-10-01

    The maintenance of the restrictive component of the Fobi pouch gastric bypass is essential for permanent weight control. Dilatation of the pouch-outlet and of the pouch itself is responsible for substantial weight gain by an increased volume per meal and binge-eating due to the rapid emptying. An endoscopic over-the-scope clip (OTSC®; Ovesco AG, Tübingen, Germany) was applied in 94 patients following gastric bypass and unintended weight gain by dilated gastro-jejunostomy to narrow the pouch-outlet. The OTSC®-clip application was safe and efficient to reduce the pouch-outlet in all cases. Best clinical results were obtained by narrowing the gastro-jejunostomy by placing two clips at opposite sites, hence reducing the outlet of more than 80%. Preferably, the clip approximated the whole thickness of the wall to avoid further dilatation of the anastomosis. Between surgery and OTSC®-clip application the mean BMI dropped from 45.8 (±3.6) to 32.8 (±1.9). At the first follow-up about 3 months (mean 118 days, ±46 days) after OTSC®-clip application the mean BMI was 29.7 (±1.8). At the second follow-up about 1 year (mean 352 days, ±66 days) after OTSC®-clip application the mean BMI was 27.4 (±3.8). The OTSC®-clip for revisional endoscopy after gastric bypass is reliable and effective in treating weight gain due to a dilated pouch-outlet with favorable short- and midterm results.

  5. A quantitative trait locus for a primary antibody response to keyhole limpet hemocyanin on chicken chromosome 14-Confirmation and candidate gene approach

    NARCIS (Netherlands)

    Siwek, M.; Slawinska, A.; Nieuwland, M.G.B.; Witkowski, A.; Zieba, G.; Minozzi, G.; Knol, E.F.; Bednarczyk, M.

    2010-01-01

    A QTL involved in the primary antibody response toward keyhole limpet hemocyanin (KLH) was detected on chicken chromosome 14 in the experimental population, which was created by crossing commercial White Leghorn and a Polish native chicken breed (green-legged partridgelike). The current QTL location

  6. Fabrication and Characterization of ZnO Nano-Clips by the Polyol-Mediated Process

    Science.gov (United States)

    Wang, Mei; Li, Ai-Dong; Kong, Ji-Zhou; Gong, You-Pin; Zhao, Chao; Tang, Yue-Feng; Wu, Di

    2018-02-01

    ZnO nano-clips with better monodispersion were prepared successfully using zinc acetate hydrate (Zn(OAc)2·nH2O) as Zn source and ethylene glycol (EG) as solvent by a simple solution-based route-polyol process. The effect of solution concentration on the formation of ZnO nano-clips has been investigated deeply. We first prove that the 0.01 M Zn(OAc)2·nH2O can react with EG without added water or alkaline, producing ZnO nano-clips with polycrystalline wurtzite structure at 170 °C. As-synthesized ZnO nano-clips contain a lot of aggregated nanocrystals ( 5 to 15 nm) with high specific surface area of 88 m2/g. The shapes of ZnO nano-clips basically keep constant with improved crystallinity after annealing at 400-600 °C. The lower solution concentration and slight amount of H2O play a decisive role in ZnO nano-clip formation. When the solution concentration is ≤ 0.0125 M, the complexing and polymerization reactions between Zn(OAc)2·nH2O and EG predominate, mainly elaborating ZnO nano-clips. When the solution concentration is ≥ 0.015 M, the alcoholysis and polycondensation reactions of Zn(OAc)2·nH2O and EG become dominant, leading to ZnO particle formation with spherical and elliptical shapes. The possible growth mechanism based on a competition between complexing and alcoholysis of Zn(OAc)2·nH2O and EG has been proposed.

  7. Primitive experience of three dimensional multi-slice spiral CT angiography for the follow-up of intracranial aneurysm clipping

    International Nuclear Information System (INIS)

    Yang Yunjun; Chen Weijian; Hu Zhangyong; Wu Enfu; Wang Meihao; Zhuge Qichuan; Zhongming; Cheng Jingliang; Ren Cuiping; Zhang Yong

    2008-01-01

    Objective To evaluate multi-slice three-dimensional CT angiography (MS 3D-CTA) for the follow-up of intracranial aneurysm clipping. Methods: MS 3D-CTA of 16 patients with intracranial aneurysm clipping were retrospectively analyzed. The patients were scanned on a 16-slice spiral CT (GE Lightspeed pro). Volume rendering(VR), thin maximum intensity projection(thin MIP) and multi-planar reconstruction (MPR) were employed in image postprocessing in all cases. Results: There were 17 clips in the 16 patients with aneurysm clipping. Six clips were located at the posterior communicating artery, 5 at the anterior communicating artery, 4 at the middle cerebral artery, and the remaining 2 clips were located at the pericallosal artery, in 1 patient. There were no abnormalities found in the aneurysm clipping region in 7 cases by MS 3D- CTA. There were residual aneurysm in 2 cases, parent artery stenosis in 4 cases, and artery spasm in 3 eases. There was no parent artery occlusion and clip displacement in all cases. VR showed excellent 3D spacial relations between the clip and parent artery in 12 cases, and showed good relations in 3 cases. The 1 case with 2 clips in the pericallosal artery showed heavy beam-hardening artifacts. The size and shape of aneurysm clips were clearly depicted by MPR and thin MIP, while 3D spacial relation of aneurysm clip and parent artery were poorly showed. Conclusion: MS 3D-CTA is a safe and efficient method for the follow-up of intracranialaneurysm clipping. Combined VR with MPR or thin MIP can well reveal postoperative changes after aneurysm clipping. (authors)

  8. 76 FR 44575 - Paper Clips From the People's Republic of China: Continuation of the Antidumping Duty Order

    Science.gov (United States)

    2011-07-26

    ..., butterfly clips, binder clips, or other paper fasteners that are not made wholly of wire of base metal and... DEPARTMENT OF COMMERCE International Trade Administration [A-570-826] Paper Clips From the People... the antidumping duty order on paper clips from the People's Republic of China (``PRC'') would likely...

  9. Using Short Movie and Television Clips in the Economics Principles Class

    Science.gov (United States)

    Sexton, Robert L.

    2006-01-01

    The author describes a teaching method that uses powerful contemporary media, movie and television clips, to demonstrate the enormous breadth and depth of economic concepts. Many different movie and television clips can be used to show the power of economic analysis. The author describes the scenes and the economic concepts within those scenes for…

  10. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (DEC VAX VMS VERSION)

    Science.gov (United States)

    Donnell, B.

    1994-01-01

    CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with

  11. Portable inference engine: An extended CLIPS for real-time production systems

    Science.gov (United States)

    Le, Thach; Homeier, Peter

    1988-01-01

    The present C-Language Integrated Production System (CLIPS) architecture has not been optimized to deal with the constraints of real-time production systems. Matching in CLIPS is based on the Rete Net algorithm, whose assumption of working memory stability might fail to be satisfied in a system subject to real-time dataflow. Further, the CLIPS forward-chaining control mechanism with a predefined conflict resultion strategy may not effectively focus the system's attention on situation-dependent current priorties, or appropriately address different kinds of knowledge which might appear in a given application. Portable Inference Engine (PIE) is a production system architecture based on CLIPS which attempts to create a more general tool while addressing the problems of real-time expert systems. Features of the PIE design include a modular knowledge base, a modified Rete Net algorithm, a bi-directional control strategy, and multiple user-defined conflict resolution strategies. Problems associated with real-time applications are analyzed and an explanation is given for how the PIE architecture addresses these problems.

  12. Magnetic resonance angiography with ultrashort echo times reduces the artefact of aneurysm clips

    International Nuclear Information System (INIS)

    Goenner, F.; Heid, O.; Remonda, L.; Schroth, G.; Loevblad, K.O.; Guzman, R.; Barth, A.

    2002-01-01

    We evaluated the ability of an ultrashort echo time (TE) three-dimensional (3D) time-of-flight (TOF) magnetic resonance angiography (MRA) sequence to reduce the metal artefact of intracranial aneurysm clips and to display adjacent cerebral arteries. In five patients (aged 8-72 years) treated with Elgiloy or Phynox aneurysm clips we prospectively performed a conventional (TE 6.0 ms) and a new ultrashort TE (TE 2.4 ms) 3D TOF MRA. We compared the diameter of the clip-induced susceptibility artefact and the detectability of flow in adjacent vessels. The mean artefact diameter was 22.3±6.4 mm (range 14-38 mm) with the ultrashort TE and 27.7±6.4 mm (range 19-45 mm) with the conventional MRA (P<0.0001). This corresponded to a diameter reduction of 19.5±9.2%. More parts of adjacent vessels were detected, but with less intense flow signal. The aneurysm dome and neck remained within the area of signal loss and were therefore not displayed. Ultrashort TE MRA is a noninvasive and fast method for improving detection of vessels adjacent to clipped intracranial aneurysms, by reducing clip-induced susceptibility artefact. The method cannot, however, be used to show remnants of the aneurysm neck or sac as a result of imperfect clipping. (orig.)

  13. Fabrication and Characterization of ZnO Nano-Clips by the Polyol-Mediated Process.

    Science.gov (United States)

    Wang, Mei; Li, Ai-Dong; Kong, Ji-Zhou; Gong, You-Pin; Zhao, Chao; Tang, Yue-Feng; Wu, Di

    2018-02-09

    ZnO nano-clips with better monodispersion were prepared successfully using zinc acetate hydrate (Zn(OAc) 2 ·nH 2 O) as Zn source and ethylene glycol (EG) as solvent by a simple solution-based route-polyol process. The effect of solution concentration on the formation of ZnO nano-clips has been investigated deeply. We first prove that the 0.01 M Zn(OAc) 2 ·nH 2 O can react with EG without added water or alkaline, producing ZnO nano-clips with polycrystalline wurtzite structure at 170 °C. As-synthesized ZnO nano-clips contain a lot of aggregated nanocrystals (~ 5 to 15 nm) with high specific surface area of 88 m 2 /g. The shapes of ZnO nano-clips basically keep constant with improved crystallinity after annealing at 400-600 °C. The lower solution concentration and slight amount of H 2 O play a decisive role in ZnO nano-clip formation. When the solution concentration is ≤ 0.0125 M, the complexing and polymerization reactions between Zn(OAc) 2 ·nH 2 O and EG predominate, mainly elaborating ZnO nano-clips. When the solution concentration is ≥ 0.015 M, the alcoholysis and polycondensation reactions of Zn(OAc) 2 ·nH 2 O and EG become dominant, leading to ZnO particle formation with spherical and elliptical shapes. The possible growth mechanism based on a competition between complexing and alcoholysis of Zn(OAc) 2 ·nH 2 O and EG has been proposed.

  14. Endoscopic clipping for gastrointestinal tumors. A method to define the target volume more precisely

    International Nuclear Information System (INIS)

    Riepl, M.; Klautke, G.; Fehr, R.; Fietkau, R.; Pietsch, A.

    2000-01-01

    Background: In many cases it is not possible to exactly define the extension of carcinoma of the gastrointestinal tract with the help of computertomography scans made for 3-D-radiation treatment planning. Consequently, the planning of external beam radiotherapy is made more difficult for the gross tumor volume as well as, in some cases, also for the clinical target volume. Patients and Methods: Eleven patients with macrosocpic tumors (rectal cancer n = 5, cardiac cancer n = 6) were included. Just before 3-D planning, the oral and aboral border of the tumor was marked endoscopically with hemoclips. Subsequently, CT scans for radiotherapy planning were made and the clinical target volume was defined. Five to 6 weeks thereafter, new CT scans were done to define the gross tumor volume for boost planning. Two investigators independently assessed the influence of the hemoclips on the different planning volumes, and whether the number of clips was sufficient to define the gross tumor volume. Results: In all patients, the implantation of the clips was done without complications. Start of radiotherapy was not delayed. With the help of the clips it was possible to exactly define the position and the extension of the primary tumor. The clinical target volume was modified according to the position of the clips in 5/11 patients; the gross tumor volume was modified in 7/11 patients. The use of the clips made the documentation and verification of the treatment portals by the simulator easier. Moreover, the clips helped the surgeon to define the primary tumor region following marked regression after neoadjuvant therapy in 3 patients. Conclusions: Endoscopic clipping of gastrointestinal tumors helps to define the tumor volumes more precisely in radiation therapy. The clips are easily recognized on the portal films and, thus, contribute to quality control. (orig.) [de

  15. Real-world experience of MitraClip for treatment of severe mitral regurgitation

    DEFF Research Database (Denmark)

    Chan, Pak Hei; She, Hoi Lam; Alegria-Barrero, Eduardo

    2012-01-01

     Percutaneous edge-to-edge mitral valve repair with the MitraClip(®) was shown to be a safe and feasible alternative compared to conventional surgical mitral valve repair. Herein is reported our experience on MitraClip(®) for high-risk surgical candidates with severe mitral regurgitation (MR)....

  16. Iterative Signal Processing for Mitigation of Analog-to-Digital Converter Clipping Distortion in Multiband OFDMA Receivers

    Directory of Open Access Journals (Sweden)

    Markus Allén

    2012-01-01

    Full Text Available In modern wideband communication receivers, the large input-signal dynamics is a fundamental problem. Unintentional signal clipping occurs, if the receiver front-end with the analog-to-digital interface cannot respond to rapidly varying conditions. This paper discusses digital postprocessing compensation of such unintentional clipping in multiband OFDMA receivers. The proposed method iteratively mitigates the clipping distortion by exploiting the symbol decisions. The performance of the proposed method is illustrated with various computer simulations and also verified by concrete laboratory measurements with commercially available analog-to-digital hardware. It is shown that the clipping compensation algorithm implemented in a turbo decoding OFDM receiver is able to remove almost all the clipping distortion even under significant clipping in fading channel circumstances. That is to say, it is possible to nearly recover the receiver performance to the level, which would be achieved in the equivalent nonclipped situation.

  17. What kind of erotic film clips should we use in female sex research? An exploratory study.

    Science.gov (United States)

    Woodard, Terri L; Collins, Karen; Perez, Mindy; Balon, Richard; Tancer, Manuel E; Kruger, Michael; Moffat, Scott; Diamond, Michael P

    2008-01-01

    Erotic film clips are used in sex research, including studies of female sexual dysfunction and arousal. However, little is known about which clips optimize female sexual response. Furthermore, their use is not well standardized. To identify the types of film clips that are most mentally appealing and physically arousing to women for use in future sexual function and dysfunction studies; to explore the relationship between mental appeal and reported physical arousal; to characterize the content of the films that were found to be the most and least appealing and arousing. Twenty-one women viewed 90 segments of erotic film clips. They rated how (i) mentally appealing and (ii) how physically aroused they were by each clip. The data were analyzed by descriptive statistics. The means of the mental and self-reported physical responses were calculated to determine the most and least appealing/arousing film clips. Pearson correlations were calculated to assess the relationship between mental appeal and reported physical arousal. Self-reported mental and physical arousal. Of 90 film clips, 18 were identified as the most mentally appealing and physically arousing while nine were identified as the least mentally appealing and physically arousing. The level of mental appeal positively correlated with the level of perceived physical arousal in both categories (r = 0.61, P Erotic film clips reliably produced a state of self-reported arousal in women. The most appealing and arousing films tended to depict heterosexual vaginal intercourse. Film clips with these attributes should be used in future research of sexual function and response of women.

  18. Effect of apical meristem clipping on carbon allocation and morphological development of white oak seedlings

    Science.gov (United States)

    Paul P. Kormanik; Shi-Jean S. Sung; T.L. Kormanik; Stanley J. Zarnoch

    1994-01-01

    Seedlings from three open-pollinated half-sib white oak seedlots were clipped in mid-July and their development was compared to nonclipped controls after one growing season.In general when data were analyzed by family, clipped seedlings were significantly less desirable in three to six of the eight variables tested.Numerically, in all families seedlots, the clipped...

  19. Psychiatric disorder associated with vacuum-assisted breast biopsy clip placement: a case report

    Directory of Open Access Journals (Sweden)

    Zografos George C

    2008-10-01

    Full Text Available Abstract Introduction Vacuum-assisted breast biopsy is a minimally invasive technique that has been used increasingly in the treatment of mammographically detected, non-palpable breast lesions. Clip placement at the biopsy site is standard practice after vacuum-assisted breast biopsy. Case presentation We present the case of a 62-year-old woman with suspicious microcalcifications in her left breast. The patient was informed about vacuum-assisted breast biopsy, including clip placement. During the course of taking the patient's history, she communicated excellently, her demeanor was normal, she disclosed no intake of psychiatric medication and had not been diagnosed with any psychiatric disorders. Subsequently, the patient underwent vacuum-assisted breast biopsy (11 G under local anesthesia. A clip was placed at the biopsy site. The pathological diagnosis was of sclerosing adenosis. At the 6-month mammographic follow-up, the radiologist mentioned the existence of the metallic clip in her breast. Subsequently, the woman presented complaining about "being spied [upon] by an implanted clip in [her] breast" and repeatedly requested the removal of the clip. The patient was referred to the specialized psychiatrist of our breast unit for evaluation. The Mental State Examination found that systematized paranoid ideas of persecutory type dominated her daily routines. At the time, she believed that the implanted clip was one of several pieces of equipment being used to keep her under surveillance, the other equipment being her telephone, cameras and television. Quite surprisingly, she had never had a consultation with a mental health professional. The patient appeared depressed and her insight into her condition was impaired. The prevalent diagnosis was schizotypal disorder, whereas the differential diagnosis comprised delusional disorder of persecutory type, affective disorder with psychotic features or comorbid delusional disorder with major depression

  20. Impact of Clipping versus Coiling on Postoperative Hemodynamics and Pulmonary Edema after Subarachnoid Hemorrhage

    Directory of Open Access Journals (Sweden)

    Nobutaka Horie

    2014-01-01

    Full Text Available Volume management is critical for assessment of cerebral vasospasm after aneurysmal subarachnoid hemorrhage (SAH. This multicenter prospective cohort study compared the impact of surgical clipping versus endovascular coiling on postoperative hemodynamics and pulmonary edema in patients with SAH. Hemodynamic parameters were measured for 14 days using a transpulmonary thermodilution system. The study included 202 patients, including 160 who underwent clipping and 42 who underwent coiling. There were no differences in global ejection fraction (GEF, cardiac index, systemic vascular resistance index, or global end-diastolic volume index between the clipping and coiling groups in the early period. However, extravascular lung water index (EVLWI and pulmonary vascular permeability index (PVPI were significantly higher in the clipping group in the vasospasm period. Postoperative C-reactive protein (CRP level was higher in the clipping group and was significantly correlated with postoperative brain natriuretic peptide level. Multivariate analysis found that PVPI and GEF were independently associated with high EVLWI in the early period, suggesting cardiogenic edema, and that CRP and PVPI, but not GEF, were independently associated with high EVLWI in the vasospasm period, suggesting noncardiogenic edema. In conclusion, clipping affects postoperative CRP level and may thereby increase noncardiogenic pulmonary edema in the vasospasm period. His trial is registered with University Hospital Medical Information Network UMIN000003794.

  1. Receiver-based recovery of clipped ofdm signals for papr reduction: A bayesian approach

    KAUST Repository

    Ali, Anum; Al-Rabah, Abdullatif R.; Masood, Mudassir; Al-Naffouri, Tareq Y.

    2014-01-01

    at the receiver for information restoration. In this paper, we acknowledge the sparse nature of the clipping signal and propose a low-complexity Bayesian clipping estimation scheme. The proposed scheme utilizes a priori information about the sparsity rate

  2. [Clip Sheets from BOCES. Opportunities. Health. Careers. = Oportunidades. Salud. Una Camera En...

    Science.gov (United States)

    State Univ. of New York, Geneseo. Coll. at Geneseo. Migrant Center.

    This collection of 83 clip sheets, or classroom handouts, was created to help U.S. migrants learn more about health, careers, and general "opportunities" including education programs. They are written in both English and Spanish and are presented in an easily understandable format. Health clip-sheet topics include the following: Abuse; AIDS;…

  3. From benchmarking HITS-CLIP peak detection programs to a new method for identification of miRNA-binding sites from Ago2-CLIP data.

    Science.gov (United States)

    Bottini, Silvia; Hamouda-Tekaya, Nedra; Tanasa, Bogdan; Zaragosi, Laure-Emmanuelle; Grandjean, Valerie; Repetto, Emanuela; Trabucchi, Michele

    2017-05-19

    Experimental evidence indicates that about 60% of miRNA-binding activity does not follow the canonical rule about the seed matching between miRNA and target mRNAs, but rather a non-canonical miRNA targeting activity outside the seed or with a seed-like motifs. Here, we propose a new unbiased method to identify canonical and non-canonical miRNA-binding sites from peaks identified by Ago2 Cross-Linked ImmunoPrecipitation associated to high-throughput sequencing (CLIP-seq). Since the quality of peaks is of pivotal importance for the final output of the proposed method, we provide a comprehensive benchmarking of four peak detection programs, namely CIMS, PIPE-CLIP, Piranha and Pyicoclip, on four publicly available Ago2-HITS-CLIP datasets and one unpublished in-house Ago2-dataset in stem cells. We measured the sensitivity, the specificity and the position accuracy toward miRNA binding sites identification, and the agreement with TargetScan. Secondly, we developed a new pipeline, called miRBShunter, to identify canonical and non-canonical miRNA-binding sites based on de novo motif identification from Ago2 peaks and prediction of miRNA::RNA heteroduplexes. miRBShunter was tested and experimentally validated on the in-house Ago2-dataset and on an Ago2-PAR-CLIP dataset in human stem cells. Overall, we provide guidelines to choose a suitable peak detection program and a new method for miRNA-target identification. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  4. Future of clip-on weapon sights: pros and cons from an applications perspective

    Science.gov (United States)

    Knight, C. Reed; Greenslade, Ken; Francisco, Glen

    2015-05-01

    US Domestic, International, allied Foreign National Warfighters and Para-Military First Responders (Police, SWAT, Special Operations, Law Enforcement, Government, Security and more) are put in harm's way all the time. To successfully complete their missions and return home safely are the primary goals of these professionals. Tactical product improvements that affect mission effectiveness and solider survivability are pivotal to understanding the past, present and future of Clip-On in-line weapon sights. Clip-On Weapon Sight (WS) technology was deemed an interim solution by the US Government for use until integrated and fused (day/night multi-sensor) Weapon Sights (WSs) were developed/fielded. Clip-On has now become the solution of choice by Users, Warriors, Soldiers and the US Government. SWaP-C (size, weight and power -cost) has been improved through progressive advances in Clip-On Image Intensified (I2), passive thermal, LL-CMOS and fused technology. Clip-On Weapon Sights are now no longer mounting position sensitive. Now they maintain aim point boresight, so they can be used for longer ranges with increased capabilities while utilizing the existing zeroed weapon and daysight optic. Active illuminated low-light level (both analog I2 and digital LL-CMOS) imaging is rightfully a real-world technology, proven to deliver daytime and low-light level identification confidence. Passive thermal imaging is also a real-world technology, proven to deliver daytime, nighttime and all-weather (including dirty battlefield) target detection confidence. Image processing detection algorithms with intelligent analytics provide documented promise to improve confidence by reducing Users, Warriors and Soldiers' work-loads and improving overall system engagement solution outcomes. In order to understand the future of Clip-On in-line weapon sights, addressing pros and cons, this paper starts with an overview of historical weapon sight applications, technologies and stakeholder decisions

  5. PAPR Reduction of FBMC by Clipping and Its Iterative Compensation

    Directory of Open Access Journals (Sweden)

    Zsolt Kollár

    2012-01-01

    Full Text Available Physical layers of communication systems using Filter Bank Multicarrier (FBMC as a modulation scheme provide low out-of-band leakage but suffer from the large Peak-to-Average Power Ratio (PAPR of the transmitted signal. Two special FBMC schemes are investigated in this paper: the Orthogonal Frequency Division Multiplexing (OFDM and the Staggered Multitone (SMT. To reduce the PAPR of the signal, time domain clipping is applied in both schemes. If the clipping is not compensated, the system performance is severely affected. To avoid this degradation, an iterative noise cancelation technique, Bussgang Noise Cancelation (BNC, is applied in the receiver. It is shown that clipping can be a good means for reducing the PAPR, especially for the SMT scheme. A novel modified BNC receiver is presented for SMT. It is shown how this technique can be implemented in real-life applications where special requirements must be met regarding the spectral characteristics of the transmitted signal.

  6. Acute Cholangitis following Intraductal Migration of Surgical Clips 10 Years after Laparoscopic Cholecystectomy

    Directory of Open Access Journals (Sweden)

    Natalie E. Cookson

    2015-01-01

    Full Text Available Background. Laparoscopic cholecystectomy represents the gold standard approach for treatment of symptomatic gallstones. Surgery-associated complications include bleeding, bile duct injury, and retained stones. Migration of surgical clips after cholecystectomy is a rare complication and may result in gallstone formation “clip cholelithiasis”. Case Report. We report a case of a 55-year-old female patient who presented with right upper quadrant pain and severe sepsis having undergone an uncomplicated laparoscopic cholecystectomy 10 years earlier. Computed tomography (CT imaging revealed hyperdense material in the common bile duct (CBD compatible with retained calculus. Endoscopic retrograde cholangiopancreatography (ERCP revealed appearances in keeping with a migrated surgical clip within the CBD. Balloon trawl successfully extracted this, alleviating the patient’s jaundice and sepsis. Conclusion. Intraductal clip migration is a rarely encountered complication after laparoscopic cholecystectomy which may lead to choledocholithiasis. Appropriate management requires timely identification and ERCP.

  7. Surgical clipping is still a good choice for the treatment of paraclinoid aneurysms

    Directory of Open Access Journals (Sweden)

    Felix Hendrik Pahl

    2016-04-01

    Full Text Available ABSTRACT Paraclinoid aneurysms are lesions located adjacent to the clinoid and ophthalmic segments of the internal carotid artery. In recent years, flow diverter stents have been introduced as a better endovascular technique for treatment of these aneurysms. Method From 2009 to 2014, a total of 43 paraclinoid aneurysms in 43 patients were surgically clipped. We retrospectively reviewed the records of these patients to analyze clinical outcomes. Results Twenty-six aneurysms (60.5% were ophthalmic artery aneurysms, while 17 were superior hypophyseal artery aneurysms (39.5%. The extradural approach to the clinoid process was used to clip these aneurysms. One hundred percent of aneurysms were clipped (complete exclusion in 100% on follow-up angiography. The length of follow-up ranged from 1 to 60 months (mean, 29.82 months. Conclusion Surgical clipping continues to be a good option for the treatment of paraclinoid aneurysms.

  8. Biochemical Analysis Reveals the Multifactorial Mechanism of Histone H3 Clipping by Chicken Liver Histone H3 Protease

    KAUST Repository

    Chauhan, Sakshi

    2016-09-02

    Proteolytic clipping of histone H3 has been identified in many organisms. Despite several studies, the mechanism of clipping, the substrate specificity, and the significance of this poorly understood epigenetic mechanism are not clear. We have previously reported histone H3 specific proteolytic clipping and a protein inhibitor in chicken liver. However, the sites of clipping are still not known very well. In this study, we attempt to identify clipping sites in histone H3 and to determine the mechanism of inhibition by stefin B protein, a cysteine protease inhibitor. By employing site-directed mutagenesis and in vitro biochemical assays, we have identified three distinct clipping sites in recombinant human histone H3 and its variants (H3.1, H3.3, and H3t). However, post-translationally modified histones isolated from chicken liver and Saccharomyces cerevisiae wild-type cells showed different clipping patterns. Clipping of histone H3 N-terminal tail at three sites occurs in a sequential manner. We have further observed that clipping sites are regulated by the structure of the N-terminal tail as well as the globular domain of histone H3. We also have identified the QVVAG region of stefin B protein to be very crucial for inhibition of the protease activity. Altogether, our comprehensive biochemical studies have revealed three distinct clipping sites in histone H3 and their regulation by the structure of histone H3, histone modifications marks, and stefin B.

  9. An optimization method for defects reduction in fiber laser keyhole welding

    Science.gov (United States)

    Ai, Yuewei; Jiang, Ping; Shao, Xinyu; Wang, Chunming; Li, Peigen; Mi, Gaoyang; Liu, Yang; Liu, Wei

    2016-01-01

    Laser welding has been widely used in automotive, power, chemical, nuclear and aerospace industries. The quality of welded joints is closely related to the existing defects which are primarily determined by the welding process parameters. This paper proposes a defects optimization method that takes the formation mechanism of welding defects and weld geometric features into consideration. The analysis of welding defects formation mechanism aims to investigate the relationship between welding defects and process parameters, and weld features are considered to identify the optimal process parameters for the desired welded joints with minimum defects. The improved back-propagation neural network possessing good modeling for nonlinear problems is adopted to establish the mathematical model and the obtained model is solved by genetic algorithm. The proposed method is validated by macroweld profile, microstructure and microhardness in the confirmation tests. The results show that the proposed method is effective at reducing welding defects and obtaining high-quality joints for fiber laser keyhole welding in practical production.

  10. Estudo da Técnica Tig Keyhole por Meio do Análise Comparativo entre Duas Tochas de Alta Produtividade na União de Chapas de Aço Carbono de Meia Espessura

    Directory of Open Access Journals (Sweden)

    Erick Alejandro González Olivares

    2015-09-01

    Full Text Available Resumo Na bibliografia de referência comum, a soldagem por meio da técnica Keyhole sempre foi associada a processos de soldagem com uma alta concentração de energia, como o processo Laser ou o processo Plasma. Novos avanços em tochas TIG estão mudando a forma em como o processo de soldagem TIG deveria ser considerado. Um exemplo desses novos avanços é a tocha comercialmente conhecida como Infocus, que segundo seus fabricantes a principal característica da tocha é a capacidade de concentração de energia na ponta do eletrodo, por médio de um aumento na potência de refrigeração do eletrodo, diferenciando à Infocus de uma tocha convencional TIG. Tal concentração de energia permite à tocha Infocus trabalhar com a técnica Keyhole. Portanto, é objetivo do presente trabalho estudar a factibilidade de uma tocha convencional TIG de usar a técnica Keyhole, com as mesmas condições de trabalho que a tocha comercialmente conhecida como Infocus. Através dos ensaios realizados foi possível confirmar que o processo TIG consegue trabalhar com a técnica Keyhole, sem necessidade de uma tocha com características especiais. Porém, o eletrodo da tocha Infocus possui uma vida maior, em comparação a um eletrodo convencional da mesma composição, aumentando a produtividade do processo.

  11. Implantation of 3D-Printed Patient-Specific Aneurysm Models into Cadaveric Specimens: A New Training Paradigm to Allow for Improvements in Cerebrovascular Surgery and Research

    Directory of Open Access Journals (Sweden)

    Arnau Benet

    2015-01-01

    Full Text Available Aim. To evaluate the feasibility of implanting 3D-printed brain aneurysm model in human cadavers and to assess their utility in neurosurgical research, complex case management/planning, and operative training. Methods. Two 3D-printed aneurysm models, basilar apex and middle cerebral artery, were generated and implanted in four cadaveric specimens. The aneurysms were implanted at the same anatomical region as the modeled patient. Pterional and orbitozygomatic approaches were done on each specimen. The aneurysm implant, manipulation capabilities, and surgical clipping were evaluated. Results. The 3D aneurysm models were successfully implanted to the cadaveric specimens’ arterial circulation in all cases. The features of the neck in terms of flexibility and its relationship with other arterial branches allowed for the practice of surgical maneuvering characteristic to aneurysm clipping. Furthermore, the relationship of the aneurysm dome with the surrounding structures allowed for better understanding of the aneurysmal local mass effect. Noticeably, all of these observations were done in a realistic environment provided by our customized embalming model for neurosurgical simulation. Conclusion. 3D aneurysms models implanted in cadaveric specimens may represent an untapped training method for replicating clip technique; for practicing certain approaches to aneurysms specific to a particular patient; and for improving neurosurgical research.

  12. Adaptive quantization-parameter clip scheme for smooth quality in H.264/AVC.

    Science.gov (United States)

    Hu, Sudeng; Wang, Hanli; Kwong, Sam

    2012-04-01

    In this paper, we investigate the issues over the smooth quality and the smooth bit rate during rate control (RC) in H.264/AVC. An adaptive quantization-parameter (Q(p)) clip scheme is proposed to optimize the quality smoothness while keeping the bit-rate fluctuation at an acceptable level. First, the frame complexity variation is studied by defining a complexity ratio between two nearby frames. Second, the range of the generated bits is analyzed to prevent the encoder buffer from overflow and underflow. Third, based on the safe range of the generated bits, an optimal Q(p) clip range is developed to reduce the quality fluctuation. Experimental results demonstrate that the proposed Q(p) clip scheme can achieve excellent performance in quality smoothness and buffer regulation.

  13. New concept of 3D printed bone clip (polylactic acid/hydroxyapatite/silk composite) for internal fixation of bone fractures.

    Science.gov (United States)

    Yeon, Yeung Kyu; Park, Hae Sang; Lee, Jung Min; Lee, Ji Seung; Lee, Young Jin; Sultan, Md Tipu; Seo, Ye Bin; Lee, Ok Joo; Kim, Soon Hee; Park, Chan Hum

    Open reduction with internal fixation is commonly used for the treatment of bone fractures. However, postoperative infection associated with internal fixation devices (intramedullary nails, plates, and screws) remains a significant complication, and it is technically difficult to fix multiple fragmented bony fractures using internal fixation devices. In addition, drilling in the bone to install devices can lead to secondary fracture, bone necrosis associated with postoperative infection. In this study, we developed bone clip type internal fixation device using three- dimensional (3D) printing technology. Standard 3D model of the bone clip was generated based on computed tomography (CT) scan of the femur in the rat. Polylacticacid (PLA), hydroxyapatite (HA), and silk were used for bone clip material. The purpose of this study was to characterize 3D printed PLA, PLA/HA, and PLA/HA/Silk composite bone clip and evaluate the feasibility of these bone clips as an internal fixation device. Based on the results, PLA/HA/Silk composite bone clip showed similar mechanical property, and superior biocompatibility compared to other types of the bone clip. PLA/HA/Silk composite bone clip demonstrated excellent alignment of the bony segments across the femur fracture site with well-positioned bone clip in an animal study. Our 3D printed bone clips have several advantages: (1) relatively noninvasive (drilling in the bone is not necessary), (2) patient-specific design (3) mechanically stable device, and (4) it provides high biocompatibility. Therefore, we suggest that our 3D printed PLA/HA/Silk composite bone clip is a possible internal fixation device.

  14. Microsurgery Simulator of Cerebral Aneurysm Clipping with Interactive Cerebral Deformation Featuring a Virtual Arachnoid.

    Science.gov (United States)

    Shono, Naoyuki; Kin, Taichi; Nomura, Seiji; Miyawaki, Satoru; Saito, Toki; Imai, Hideaki; Nakatomi, Hirofumi; Oyama, Hiroshi; Saito, Nobuhito

    2018-05-01

    A virtual reality simulator for aneurysmal clipping surgery is an attractive research target for neurosurgeons. Brain deformation is one of the most important functionalities necessary for an accurate clipping simulator and is vastly affected by the status of the supporting tissue, such as the arachnoid membrane. However, no virtual reality simulator implementing the supporting tissue of the brain has yet been developed. To develop a virtual reality clipping simulator possessing interactive brain deforming capability closely dependent on arachnoid dissection and apply it to clinical cases. Three-dimensional computer graphics models of cerebral tissue and surrounding structures were extracted from medical images. We developed a new method for modifiable cerebral tissue complex deformation by incorporating a nonmedical image-derived virtual arachnoid/trabecula in a process called multitissue integrated interactive deformation (MTIID). MTIID made it possible for cerebral tissue complexes to selectively deform at the site of dissection. Simulations for 8 cases of actual clipping surgery were performed before surgery and evaluated for their usefulness in surgical approach planning. Preoperatively, each operative field was precisely reproduced and visualized with the virtual brain retraction defined by users. The clear visualization of the optimal approach to treating the aneurysm via an appropriate arachnoid incision was possible with MTIID. A virtual clipping simulator mainly focusing on supporting tissues and less on physical properties seemed to be useful in the surgical simulation of cerebral aneurysm clipping. To our knowledge, this article is the first to report brain deformation based on supporting tissues.

  15. Simple device to determine the pressure applied by pressure clips for the treatment of earlobe keloids

    Directory of Open Access Journals (Sweden)

    Aashish Sasidharan

    2015-01-01

    Full Text Available Background: Keloids of the ear are common problems. Various treatment modalities are available for the treatment of ear keloids. Surgical excision with intralesional steroid injection along with compression therapy has the least recurrence rate. Various types of devices are available for pressure therapy. Pressure applied by these devices is uncontrolled and is associated with the risk of pressure necrosis. We describe here a simple and easy to use device to measure pressure applied by these clips for better outcome. Objectives: To devise a simple method to measure the pressure applied by various pressure clips used in ear keloid pressure therapy. Materials and Methods: By using a force sensitive resistor (FSR, the pressure applied gets converted into voltage using electrical wires, resistors, capacitors, converter, amplifier, diode, nine-volt (9V cadmium battery and the voltage is measured using a multimeter. The measured voltage is then converted into pressure using pressure voltage graph that depicts the actual pressure applied by the pressure clip. Results: The pressure applied by different clips was variable. The spring clips were adjustable by slight variation in the design whereas the pressure applied by binder clips and magnet discs was not adjustable. Conclusion: The uncontrolled/suboptimal pressure applied by certain pressure clips can be monitored to provide optimal pressure therapy in ear keloid for better outcome.

  16. 76 FR 26242 - Paper Clips From the People's Republic of China: Final Results of Expedited Sunset Review of...

    Science.gov (United States)

    2011-05-06

    ... order are plastic and vinyl covered paper clips, butterfly clips, binder clips, or other paper fasteners... order is revoked. Parties can obtain a public copy of the I&D Memo from the Central Records Unit, room...

  17. Advantages in imaging results with titanium aneurysm clips (TiAl6V4)

    International Nuclear Information System (INIS)

    Piepgras, A.; Gueckel, F.; Weik, T.; Schmiedek, P.

    1995-01-01

    Aneurysm clips made of a titanium alloy (TiAl6V4) were used in clinical practice for the first time. The design of the clips is identical to the routinely used Yasargil series. In 30 patients, 38 symptomatic and asymptomatic aneurysms were fixed with 45 clips. Metallurgical advantages of the new alloy are better biocompatibility, less magnetic susceptibility, and lower X-ray density. The postoperative imaging results are superior to the conventionally used alloys with respect to artifact reduction in computed tomography, angiography, and magnetic resonance imaging. With a follow-up period of 7 months, a statement on biocompatibility cannot yet be given. (orig.) [de

  18. Ingested bread clip as an unexpected diagnostic tool.

    Science.gov (United States)

    Jay, Sharon M; Russell, Michael J; Lau, Yee C; Dunn, Joel W; Roberts, Ross

    2018-03-23

    We describe a case where a bread clip has in fact became lodged adjacent to a portion of small bowel affected by a deposit of previously undiagnosed metastatic serous carcinoma of likely ovarian origin.

  19. Capturing Students' Attention: Movie Clips Set the Stage for Learning in Abnormal Psychology.

    Science.gov (United States)

    Badura, Amy S.

    2002-01-01

    Presents results of a study that evaluated using popular movie clips, shown in the first class meeting of an abnormal psychology course, in relation to student enthusiasm. Compares two classes of female juniors, one using clips and one class not using them. States that the films portrayed psychological disorders. (CMK)

  20. 76 FR 31360 - Paper Clips From China; Scheduling of an Expedited Five-Year Review Concerning the Antidumping...

    Science.gov (United States)

    2011-05-31

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-663 Third Review] Paper Clips From China; Scheduling of an Expedited Five-Year Review Concerning the Antidumping Duty Order on Paper Clips From China... paper clips from China would be likely to lead to continuation or recurrence of material injury within a...

  1. Physiological remodeling of bifurcation aneurysms: preclinical results of the eCLIPs device.

    Science.gov (United States)

    Marotta, Thomas R; Riina, Howard A; McDougall, Ian; Ricci, Donald R; Killer-Oberpfalzer, Monika

    2018-02-01

    OBJECTIVE Intracranial bifurcation aneurysms are complex lesions for which current therapy, including simple coiling, balloon- or stent-assisted coiling, coil retention, or intrasaccular devices, is inadequate. Thromboembolic complications due to a large burden of intraluminal metal, impedance of access to side branches, and a high recurrence rate, due largely to the unmitigated high-pressure flow into the aneurysm (water hammer effect), are among the limitations imposed by current therapy. The authors describe herein a novel device, eCLIPs, and its use in a preclinical laboratory study that suggests the device's design and functional features may overcome many of these limitations. METHODS A preclinical model of wide-necked bifurcation aneurysms in rabbits was used to assess functional features and efficacy of aneurysm occlusion by the eCLIPs device. RESULTS The eCLIPs device, in bridging the aneurysm neck, allows coil retention, disrupts flow away from the aneurysm, leaves the main vessel and side branches unencumbered by intraluminal metal, and serves as a platform for endothelial growth across the neck, excluding the aneurysm from the circulation. CONCLUSIONS The eCLIPs device permits physiological remodeling of the bifurcation.

  2. A systematic review of discomfort due to toe or ear clipping in laboratory rodents

    NARCIS (Netherlands)

    Wever, K.E.; Geessink, F.J.; Brouwer, M.A.E.; Tillema, A.; Ritskes-Hoitinga, M.

    2017-01-01

    Toe clipping and ear clipping (also ear notching or ear punching) are frequently used methods for individual identification of laboratory rodents. These procedures potentially cause severe discomfort, which can reduce animal welfare and distort experimental results. However, no systematic summary of

  3. Current opinion on clip placement after breast biopsy: A survey of practising radiologists in France and Quebec

    International Nuclear Information System (INIS)

    Thomassin-Naggara, I.; Jalaguier-Coudray, A.; Chopier, J.; Tardivon, A.; Trop, I.

    2013-01-01

    Aim: To investigate current practice regarding clip placement after breast biopsy. Materials and methods: In June 2011, an online survey instrument was designed using an Internet-based survey site ( (www.surveymonkey.com)) to assess practices and opinions of breast radiologists regarding clip placement after breast biopsy. Radiologists were asked to give personal practice data, describe their current practice regarding clip deployment under stereotactic, ultrasonographic, and magnetic resonance imaging (MRI) guidance, and describe what steps are taken to ensure quality control with regards to clip deployment. Results: The response rate was 29.9% in France (131 respondents) and 46.7% in Quebec (50 respondents). The great majority of respondents used breast markers in their practice (92.1% in France and 96% in Quebec). In both countries, most reported deploying a clip after percutaneous biopsy under stereotactic or MRI guidance. Regarding clip deployment under ultrasonography, 38% of Quebec radiologists systematically placed a marker after each biopsy, whereas 30% of French radiologists never placed a marker in this situation, mainly due to its cost. Finally, 56.4% of radiologists in France and 54% in Quebec considered that their practice regarding clip deployment after breast percutaneous biopsy had changed in the last 5 years. Conclusion: There continues to be variations in the use of biopsy clips after imaging-guided biopsies, particularly with regards to sonographic techniques. These variations are likely to decrease over time, with the standardization of relatively new investigation protocols

  4. The role of surgical clips in the evaluation of interfractional uncertainty for treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy

    International Nuclear Information System (INIS)

    Bae, Jin Suk; Kim, Dong Hyun; Kim, Won Taek; Kim, Yong Ho; Park, Dahl; Ki, Yong Kan

    2017-01-01

    To evaluate the utility of implanted surgical clips for detecting interfractional errors in the treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy (PORT). Twenty patients had been treated with PORT for locally advanced hepatobiliary or pancreatic cancer, from November 2014 to April 2016. Patients underwent computed tomography simulation and were treated in expiratory breathing phase. During treatment, orthogonal kilovoltage (kV) imaging was taken twice a week, and isocenter shifts were made to match bony anatomy. The difference in position of clips between kV images and digitally reconstructed radiographs was determined. Clips were consist of 3 proximal clips (clip_p, ≤2 cm) and 3 distal clips (clip_d, >2 cm), which were classified according to distance from treatment center. The interfractional displacements of clips were measured in the superior-inferior (SI), anterior-posterior (AP), and right-left (RL) directions. The translocation of clip was well correlated with diaphragm movement in 90.4% (190/210) of all images. The clip position errors greater than 5 mm were observed in 26.0% in SI, 1.8% in AP, and 5.4% in RL directions, respectively. Moreover, the clip position errors greater than 10 mm were observed in 1.9% in SI, 0.2% in AP, and 0.2% in RL directions, despite respiratory control. Quantitative analysis of surgical clip displacement reflect respiratory motion, setup errors and postoperative change of intraabdominal organ position. Furthermore, position of clips is distinguished easily in verification images. The identification of the surgical clip position may lead to a significant improvement in the accuracy of upper abdominal radiation therapy

  5. The role of surgical clips in the evaluation of interfractional uncertainty for treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jin Suk; Kim, Dong Hyun; Kim, Won Taek; Kim, Yong Ho; Park, Dahl; Ki, Yong Kan [Pusan National University Hospital, Pusan National University School of Medicine, Busan (Korea, Republic of)

    2017-03-15

    To evaluate the utility of implanted surgical clips for detecting interfractional errors in the treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy (PORT). Twenty patients had been treated with PORT for locally advanced hepatobiliary or pancreatic cancer, from November 2014 to April 2016. Patients underwent computed tomography simulation and were treated in expiratory breathing phase. During treatment, orthogonal kilovoltage (kV) imaging was taken twice a week, and isocenter shifts were made to match bony anatomy. The difference in position of clips between kV images and digitally reconstructed radiographs was determined. Clips were consist of 3 proximal clips (clip{sub p}, ≤2 cm) and 3 distal clips (clip{sub d}, >2 cm), which were classified according to distance from treatment center. The interfractional displacements of clips were measured in the superior-inferior (SI), anterior-posterior (AP), and right-left (RL) directions. The translocation of clip was well correlated with diaphragm movement in 90.4% (190/210) of all images. The clip position errors greater than 5 mm were observed in 26.0% in SI, 1.8% in AP, and 5.4% in RL directions, respectively. Moreover, the clip position errors greater than 10 mm were observed in 1.9% in SI, 0.2% in AP, and 0.2% in RL directions, despite respiratory control. Quantitative analysis of surgical clip displacement reflect respiratory motion, setup errors and postoperative change of intraabdominal organ position. Furthermore, position of clips is distinguished easily in verification images. The identification of the surgical clip position may lead to a significant improvement in the accuracy of upper abdominal radiation therapy.

  6. Functional outcome of microsurgical clipping compared to endovascular coiling.

    Science.gov (United States)

    Premananda, R M; Ramesh, N; Hillol, K P

    2012-12-01

    Endovascular coiling has been used increasingly as an alternative to neurosurgical clipping for treating subarachnoid hemorrhage secondary to aneurysm rupture. In a retrospective cohort review on the treatment methods of aneurysm rupture in Hospital Kuala Lumpur over the period of five years (2005-2009) a total of 268 patients were treated. These patients were broadly categorized into two groups based on their treatment mode for ruptured aneurysms. Statistical analysis was determined using Chi- Square tests to study these associations. In our study, 67.5% of patients presented with Good World Federation of Neurosurgical Societies (WFNS) grade (WFNS1-2) while 32.5% patients presented with Poor WFNS prior to intervention. In our outcome, it was noted that 60.4% had good functional outcome (mRS grade 0-2) as compared to 39.6% patients who had poor mRS(modified rankin scale) outcome (mRS 3-6). In the good WFNS group, 76% of patients in clipping group had a good mRS outcome while, 86.5% patients in coiling group had good mRS outcome (p=0.114). In poor WFNS presentation, it was noted that in 77.3% patients in clipping group, had poor mRS outcome. Similarly with poor WFNS presentation, 83.3% of patient in coiling group had poor outcome. (p=1.00). Hence when we control the WFNS group, there was no significant association between treatment group (clipping and coiling) and mRS outcome at 6 months. The outcome of patient is determined by initial clinical presentation (WFNS grade) and influenced by requirement of Extraventricular drain (EVD) in presence of hydrocephalus, CSF infection and pneumonia. Therefore the decision regarding treatment option needs to be individualized based on the presentation of the patient.

  7. Vision-based weld pool boundary extraction and width measurement during keyhole fiber laser welding

    Science.gov (United States)

    Luo, Masiyang; Shin, Yung C.

    2015-01-01

    In keyhole fiber laser welding processes, the weld pool behavior is essential to determining welding quality. To better observe and control the welding process, the accurate extraction of the weld pool boundary as well as the width is required. This work presents a weld pool edge detection technique based on an off axial green illumination laser and a coaxial image capturing system that consists of a CMOS camera and optic filters. According to the difference of image quality, a complete developed edge detection algorithm is proposed based on the local maximum gradient of greyness searching approach and linear interpolation. The extracted weld pool geometry and the width are validated by the actual welding width measurement and predictions by a numerical multi-phase model.

  8. Development of a new biodegradable operative clip made of a magnesium alloy: Evaluation of its safety and tolerability for canine cholecystectomy.

    Science.gov (United States)

    Yoshida, Toshihiko; Fukumoto, Takumi; Urade, Takeshi; Kido, Masahiro; Toyama, Hirochika; Asari, Sadaki; Ajiki, Tetsuo; Ikeo, Naoko; Mukai, Toshiji; Ku, Yonson

    2017-06-01

    Operative clips used to ligate vessels in abdominal operation usually are made of titanium. They remain in the body permanently and form metallic artifacts in computed tomography images, which impair accurate diagnosis. Although biodegradable magnesium instruments have been developed in other fields, the physical properties necessary for operative clips differ from those of other instruments. We developed a biodegradable magnesium-zinc-calcium alloy clip with good biologic compatibility and enough clamping capability as an operative clip. In this study, we verified the safety and tolerability of this clip for use in canine cholecystectomy. Nine female beagles were used. We performed cholecystectomy and ligated the cystic duct by magnesium alloy or titanium clips. The chronologic change of clips and artifact formation were compared at 1, 4, 12, 18, and 24 weeks postoperative by computed tomography. The animals were killed at the end of the observation period, and the clips were removed to evaluate their biodegradability. We also evaluated their effect on the living body by blood biochemistry data. The magnesium alloy clip formed much fewer artifacts than the titanium clip, and it was almost absorbed at 6 months postoperative. There were no postoperative complications and no elevation of constituent elements such as magnesium, calcium, and zinc during the observation period in both groups. The novel magnesium alloy clip demonstrated sufficient sealing capability for the cystic duct and proper biodegradability in canine models. The magnesium alloy clip revealed much fewer metallic artifacts in CT than the conventional titanium clip. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Heavy metal phytoextraction by Sedum alfredii is affected by continual clipping and phosphorus fertilization amendment.

    Science.gov (United States)

    Huang, Huagang; Li, Tingqiang; Gupta, D K; He, Zhenli; Yang, Xiao-E; Ni, Bingnan; Li, Mao

    2012-01-01

    Improving the efficacy of phytoextraction is critical for its successful application in metal contaminated soils. Mineral nutrition affects plant growth and metal absorption and subsequently the accumulation of heavy metal through hyper-accumulator plants. This study assessed the effects of di-hydrogen phosphates (KH2PO4, Ca(H2PO4)2, NaH2PO4 and NH4H2PO4) application at three levels (22, 88 and 352 mg P/kg soil) on Sedum alfredii growth and metal uptake by three consecutive harvests on aged and Zn/Cd combined contaminated paddy soil. The addition of phosphates (P) significantly increased the amount of Zn taken up by S. alfredii due to increased shoot Zn concentration and dry matter yield (DMY) (P phytoextraction of Zn and Cd was observed in KH2PO4 and NH4H2PO4 treatment at 352 mg P/kg soil. The amount of Zn removed by phytoextraction increased in the order of 1st clipping < 2nd clipping < 3rd clipping, and for Cd extraction the order was 2nd clipping < 1st clipping < 3rd clipping. These results indicate that the application of P fertilizers coupled with multiple cuttings can enhance the removal of Zn and Cd from contaminated soils by S. alfredii, thus shortening the time needed for accomplishing remediation goals.

  10. Anterior petroclinoid fold fenestration: an adjunct to clipping of postero-laterally projecting posterior communicating aneurysms.

    Science.gov (United States)

    Nossek, Erez; Setton, Avi; Dehdashti, Amir R; Chalif, David J

    2014-10-01

    Proximally located posterior communicating artery (PCoA) aneurysms, projecting postero-laterally in proximity to the tentorium, may pose a technical challenge for microsurgical clipping due to obscuration of the proximal aneurysmal neck by the anterior petroclinoid fold. We describe an efficacious technique utilizing fenestration of the anterior petroclinoid fold to facilitate visualization and clipping of PCoA aneurysms abutting this aspect of the tentorium. Of 86 cases of PCoA aneurysms treated between 2003 and 2013, the technique was used in nine (10.5 %) patients to allow for adequate clipping. A 3 mm fenestration in the anterior petroclinoid ligament is created adjacent and lateral to the anterior clinoid process. This fenestration is then widened into a small wedge corridor by bipolar coagulation. In all cases, the proximal aneurysm neck was visualized after the wedge fenestration. Additionally, an adequate corridor for placement of the proximal clip blade was uniformly established. All cases were adequately clipped, with complete occlusion of the aneurysm neck and fundus with preservation of the PCoA. There were two intraoperative ruptures not related to creation of the wedge fenestration. One patient experienced post-operative partial third nerve palsy, which resolved during follow-up. We describe a technique of fenestration of the anterior petroclinoid fold to establish a critical and safe corridor for both visualization and clipping of PCoA aneurysms.

  11. Anticipation of high arousal aversive and positive movie clips engages common and distinct neural substrates.

    Science.gov (United States)

    Greenberg, Tsafrir; Carlson, Joshua M; Rubin, Denis; Cha, Jiook; Mujica-Parodi, Lilianne

    2015-04-01

    The neural correlates of anxious anticipation have been primarily studied with aversive and neutral stimuli. In this study, we examined the effect of valence on anticipation by using high arousal aversive and positive stimuli and a condition of uncertainty (i.e. either positive or aversive). The task consisted of predetermined cues warning participants of upcoming aversive, positive, 'uncertain' (either aversive or positive) and neutral movie clips. Anticipation of all affective clips engaged common regions including the anterior insula, dorsal anterior cingulate cortex, thalamus, caudate, inferior parietal and prefrontal cortex that are associated with emotional experience, sustained attention and appraisal. In contrast, the nucleus accumbens and medial prefrontal cortex, regions implicated in reward processing, were selectively engaged during anticipation of positive clips (depicting sexually explicit content) and the mid-insula, which has been linked to processing aversive stimuli, was selectively engaged during anticipation of aversive clips (depicting graphic medical procedures); these three areas were also activated during anticipation of 'uncertain' clips reflecting a broad preparatory response for both aversive and positive stimuli. These results suggest that a common circuitry is recruited in anticipation of affective clips regardless of valence, with additional areas preferentially engaged depending on whether expected stimuli are negative or positive. © The Author (2014). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  12. MicroRNA transfection and AGO-bound CLIP-seq data sets reveal distinct determinants of miRNA action

    DEFF Research Database (Denmark)

    Wen, Jiayu; Parker, Brian J; Jacobsen, Anders

    2011-01-01

    the predictive effect of target flanking features. We observe distinct target determinants between expression-based and CLIP-based data. Target flanking features such as flanking region conservation are an important AGO-binding determinant-we hypothesize that CLIP experiments have a preference for strongly bound......Microarray expression analyses following miRNA transfection/inhibition and, more recently, Argonaute cross-linked immunoprecipitation (CLIP)-seq assays have been used to detect miRNA target sites. CLIP and expression approaches measure differing stages of miRNA functioning-initial binding of the mi...... miRNP-target interactions involving adjacent RNA-binding proteins that increase the strength of cross-linking. In contrast, seed-related features are major determinants in expression-based studies, but less so for CLIP-seq studies, and increased miRNA concentrations typical of transfection studies...

  13. YUCSA: A CLIPS expert database system to monitor academic performance

    Science.gov (United States)

    Toptsis, Anestis A.; Ho, Frankie; Leindekar, Milton; Foon, Debra Low; Carbonaro, Mike

    1991-01-01

    The York University CLIPS Student Administrator (YUCSA), an expert database system implemented in C Language Integrated Processing System (CLIPS), for monitoring the academic performance of undergraduate students at York University, is discussed. The expert system component in the system has already been implemented for two major departments, and it is under testing and enhancement for more departments. Also, more elaborate user interfaces are under development. We describe the design and implementation of the system, problems encountered, and immediate future plans. The system has excellent maintainability and it is very efficient, taking less than one minute to complete an assessment of one student.

  14. Phosphorus runoff from turfgrass as affected by phosphorus fertilization and clipping management.

    Science.gov (United States)

    Bierman, Peter M; Horgan, Brian P; Rosen, Carl J; Hollman, Andrew B; Pagliari, Paulo H

    2010-01-01

    Phosphorus enrichment of surface water is a concern in many urban watersheds. A 3-yr study on a silt loam soil with 5% slope and high soil test P (27 mg kg(-1) Bray P1) was conducted to evaluate P fertilization and clipping management effects on P runoff from turfgrass (Poa pratensis L.) under frozen and nonfrozen conditions. Four fertilizer treatments were compared: (i) no fertilizer, (ii) nitrogen (N)+potassium (K)+0xP, (iii) N+K+1xP, and (iv) N+K+3xP. Phosphorus rates were 21.3 and 63.9 kg ha(-1) yr(-1) the first year and 7.1 and 21.3 kg ha(-1) yr(-1) the following 2 yr. Each fertilizer treatment was evaluated with clippings removed or clippings recycled back to the turf. In the first year, P runoff increased with increasing P rate and P losses were greater in runoff from frozen than nonfrozen soil. In year 2, total P runoff from the no fertilizer treatment was greater than from treatments receiving fertilizer. This was because reduced turf quality resulted in greater runoff depth from the no fertilizer treatment. In year 3, total P runoff from frozen soil and cumulative total P runoff increased with increasing P rate. Clipping management was not an important factor in any year, indicating that returning clippings does not significantly increase P runoff from turf. In the presence of N and K, P fertilization did not improve turf growth or quality in any year. Phosphorus runoff can be reduced by not applying P to high testing soils and avoiding fall applications when P is needed.

  15. 76 FR 42730 - Paper Clips From China

    Science.gov (United States)

    2011-07-19

    ... China Determination On the basis of the record \\1\\ developed in the subject five-year review, the United... China would be likely to lead to continuation or recurrence of material injury to an industry in the...), entitled Paper Clips from China: Investigation No. 731-TA-663 (Third Review). By order of the Commission...

  16. Nonvariceal Upper Gastrointestinal Bleeding: the Usefulness of Rotational Angiography after Endoscopic Marking with a Metallic Clip

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ji Soo; Kwak, Hyo Sung; Chung, Gyung Ho [Chonbuk National University Medical School, Chonju (Korea, Republic of)

    2011-08-15

    We wanted to assess the usefulness of rotational angiography after endoscopic marking with a metallic clip in upper gastrointestinal bleeding patients with no extravasation of contrast medium on conventional angiography. In 16 patients (mean age, 59.4 years) with acute bleeding ulcers (13 gastric ulcers, 2 duodenal ulcers, 1 malignant ulcer), a metallic clip was placed via gastroscopy and this had been preceded by routine endoscopic treatment. The metallic clip was placed in the fibrous edge of the ulcer adjacent to the bleeding point. All patients had negative results from their angiographic studies. To localize the bleeding focus, rotational angiography and high pressure angiography as close as possible to the clip were used. Of the 16 patients, seven (44%) had positive results after high pressure angiography as close as possible to the clip and they underwent transcatheter arterial embolization (TAE) with microcoils. Nine patients without extravasation of contrast medium underwent TAE with microcoils as close as possible to the clip. The bleeding was stopped initially in all patients after treatment of the feeding artery. Two patients experienced a repeat episode of bleeding two days later. Of the two patients, one had subtle oozing from the ulcer margin and that patient underwent endoscopic treatment. One patient with malignant ulcer died due to disseminated intravascular coagulation one month after embolization. Complete clinical success was achieved in 14 of 16 (88%) patients. Delayed bleeding or major/minor complications were not noted. Rotational angiography after marking with a metallic clip helps to localize accurately the bleeding focus and thus to embolize the vessel correctly.

  17. Nonvariceal Upper Gastrointestinal Bleeding: the Usefulness of Rotational Angiography after Endoscopic Marking with a Metallic Clip

    International Nuclear Information System (INIS)

    Song, Ji Soo; Kwak, Hyo Sung; Chung, Gyung Ho

    2011-01-01

    We wanted to assess the usefulness of rotational angiography after endoscopic marking with a metallic clip in upper gastrointestinal bleeding patients with no extravasation of contrast medium on conventional angiography. In 16 patients (mean age, 59.4 years) with acute bleeding ulcers (13 gastric ulcers, 2 duodenal ulcers, 1 malignant ulcer), a metallic clip was placed via gastroscopy and this had been preceded by routine endoscopic treatment. The metallic clip was placed in the fibrous edge of the ulcer adjacent to the bleeding point. All patients had negative results from their angiographic studies. To localize the bleeding focus, rotational angiography and high pressure angiography as close as possible to the clip were used. Of the 16 patients, seven (44%) had positive results after high pressure angiography as close as possible to the clip and they underwent transcatheter arterial embolization (TAE) with microcoils. Nine patients without extravasation of contrast medium underwent TAE with microcoils as close as possible to the clip. The bleeding was stopped initially in all patients after treatment of the feeding artery. Two patients experienced a repeat episode of bleeding two days later. Of the two patients, one had subtle oozing from the ulcer margin and that patient underwent endoscopic treatment. One patient with malignant ulcer died due to disseminated intravascular coagulation one month after embolization. Complete clinical success was achieved in 14 of 16 (88%) patients. Delayed bleeding or major/minor complications were not noted. Rotational angiography after marking with a metallic clip helps to localize accurately the bleeding focus and thus to embolize the vessel correctly.

  18. The effect of music video clips on adolescent boys' body image, mood, and schema activation.

    Science.gov (United States)

    Mulgrew, Kate E; Volcevski-Kostas, Diana; Rendell, Peter G

    2014-01-01

    There is limited research that has examined experimentally the effects of muscular images on adolescent boys' body image, with no research specifically examining the effects of music television. The aim of the current study was to examine the effects of viewing muscular and attractive singers in music video clips on early, mid, and late adolescent boys' body image, mood, and schema activation. Participants were 180 boys in grade 7 (mean age = 12.73 years), grade 9 (mean age = 14.40 years) or grade 11 (mean age = 16.15 years) who completed pre- and post-test measures of mood and body satisfaction after viewing music videos containing male singers of muscular or average appearance. They also completed measures of schema activation and social comparison after viewing the clips. The results showed that the boys who viewed the muscular clips reported poorer upper body satisfaction, lower appearance satisfaction, lower happiness, and more depressive feelings compared to boys who viewed the clips depicting singers of average appearance. There was no evidence of increased appearance schema activation but the boys who viewed the muscular clips did report higher levels of social comparison to the singers. The results suggest that music video clips are a powerful form of media in conveying information about the male ideal body shape and that negative effects are found in boys as young as 12 years.

  19. TH-EF-BRA-05: A Method of Near Real-Time 4D MRI Using Volumetric Dynamic Keyhole (VDK) in the Presence of Respiratory Motion for MR-Guided Radiotherapy

    International Nuclear Information System (INIS)

    Lewis, B; Kim, S; Kim, T

    2016-01-01

    Purpose: To develop a novel method that enables 4D MR imaging in near real-time for continuous monitoring of tumor motion in MR-guided radiotherapy. Methods: This method is mainly based on an idea of expanding dynamic keyhole to full volumetric imaging acquisition. In the VDK approach introduced in this study, a library of peripheral volumetric k-space data is generated in given number of phases (5 and 10 in this study) in advance. For 4D MRI at any given time, only volumetric central k-space data are acquired in real-time and combined with pre-acquired peripheral volumetric k-space data in the library corresponding to the respiratory phase (or amplitude). The combined k-space data are Fourier-transformed to MR images. For simulation study, an MRXCAT program was used to generate synthetic MR images of the thorax with desired respiratory motion, contrast levels, and spatial and temporal resolution. 20 phases of volumetric MR images, with 200 ms temporal resolution in 4 s respiratory period, were generated using balanced steady-state free precession MR pulse sequence. The total acquisition time was 21.5s/phase with a voxel size of 3×3×5 mm 3 and an image matrix of 128×128×56. Image similarity was evaluated with difference maps between the reference and reconstructed images. The VDK, conventional keyhole, and zero filling methods were compared for this simulation study. Results: Using 80% of the ky data and 70% of the kz data from the library resulted in 12.20% average intensity difference from the reference, and 21.60% and 28.45% difference in threshold pixel difference for conventional keyhole and zero filling, respectively. The imaging time will be reduced from 21.5s to 1.3s per volume using the VDK method. Conclusion: Near real-time 4D MR imaging can be achieved using the volumetric dynamic keyhole method. That makes the possibility of utilizing 4D MRI during MR-guided radiotherapy.

  20. Virtual reality cerebral aneurysm clipping simulation with real-time haptic feedback.

    Science.gov (United States)

    Alaraj, Ali; Luciano, Cristian J; Bailey, Daniel P; Elsenousi, Abdussalam; Roitberg, Ben Z; Bernardo, Antonio; Banerjee, P Pat; Charbel, Fady T

    2015-03-01

    With the decrease in the number of cerebral aneurysms treated surgically and the increase of complexity of those treated surgically, there is a need for simulation-based tools to teach future neurosurgeons the operative techniques of aneurysm clipping. To develop and evaluate the usefulness of a new haptic-based virtual reality simulator in the training of neurosurgical residents. A real-time sensory haptic feedback virtual reality aneurysm clipping simulator was developed using the ImmersiveTouch platform. A prototype middle cerebral artery aneurysm simulation was created from a computed tomographic angiogram. Aneurysm and vessel volume deformation and haptic feedback are provided in a 3-dimensional immersive virtual reality environment. Intraoperative aneurysm rupture was also simulated. Seventeen neurosurgery residents from 3 residency programs tested the simulator and provided feedback on its usefulness and resemblance to real aneurysm clipping surgery. Residents thought that the simulation would be useful in preparing for real-life surgery. About two-thirds of the residents thought that the 3-dimensional immersive anatomic details provided a close resemblance to real operative anatomy and accurate guidance for deciding surgical approaches. They thought the simulation was useful for preoperative surgical rehearsal and neurosurgical training. A third of the residents thought that the technology in its current form provided realistic haptic feedback for aneurysm surgery. Neurosurgical residents thought that the novel immersive VR simulator is helpful in their training, especially because they do not get a chance to perform aneurysm clippings until late in their residency programs.

  1. Use of a surgical rehearsal platform and improvement in aneurysm clipping measures: results of a prospective, randomized trial.

    Science.gov (United States)

    Chugh, A Jessey; Pace, Jonathan R; Singer, Justin; Tatsuoka, Curtis; Hoffer, Alan; Selman, Warren R; Bambakidis, Nicholas C

    2017-03-01

    OBJECTIVE The field of neurosurgery is constantly undergoing improvements and advances, both in technique and technology. Cerebrovascular neurosurgery is no exception, with endovascular treatments changing the treatment paradigm. Clipping of aneurysms is still necessary, however, and advances are still being made to improve patient outcomes within the microsurgical treatment of aneurysms. Surgical rehearsal platforms are surgical simulators that offer the opportunity to rehearse a procedure prior to entering the operative suite. This study is designed to determine whether use of a surgical rehearsal platform in aneurysm surgery is helpful in decreasing aneurysm dissection time and clip manipulation of the aneurysm. METHODS The authors conducted a blinded, prospective, randomized study comparing key effort and time variables in aneurysm clip ligation surgery with and without preoperative use of the SuRgical Planner (SRP) surgical rehearsal platform. Initially, 40 patients were randomly assigned to either of two groups: one in which surgery was performed after use of the SRP (SRP group) and one in which surgery was performed without use of the SRP (control group). All operations were videotaped. After exclusion of 6 patients from the SRP group and 9 from the control group, a total of 25 surgical cases were analyzed by a reviewer blinded to group assignment. The videos were analyzed for total microsurgical time, number of clips used, and number of clip placement attempts. Means and standard deviations (SDs) were calculated and compared between groups. RESULTS The mean (± SD) amount of operative time per clip used was 920 ± 770 seconds in the SRP group and 1294 ± 678 seconds in the control group (p = 0.05). In addition, the mean values for the number of clip attempts, total operative time, ratio of clip attempts to clips used, and time per clip attempt were all lower in the SRP group, although the between-group differences were not statistically significant

  2. The "Isms" of Art. Introduction to the 2001-2002 Clip and Save Art Prints.

    Science.gov (United States)

    Hubbard, Guy

    2001-01-01

    Provides an introduction to the 2001-2002 Clip and Save Art Prints that will focus on ten art movements from the past 150 years. Includes information on three art movements, or "isms": Classicism, Romanticism, and Realism. Discusses the Clip and Save Art Print format and provides information on three artists. (CMK)

  3. Our History Clips: Collaborating for the Common Good

    Science.gov (United States)

    Bailey, Beatrice N.

    2017-01-01

    This case study reveals how middle school social studies teachers within a professional development program are encouraging their students to use multiple disciplinary literacies to create Our History Clips as they also work toward developing a classroom community of engaged student citizens.

  4. ASTP 15th Anniversary Clip-Media Release

    Science.gov (United States)

    1990-01-01

    This release is comprised of 5 separate clips, including the following: CL 762 Astronauts/Cosmonauts Visit to KSC and Walt Disney World; CL 739 ASTP Joint Crew Activities; CL 748 ASTP Astronauts/Cosmonauts Horlock Ranch Visit; CL 758 T-21 ASTP Training - US/USSR; and CL 743 ASTP Joint Crew Training in the Soviet Union.

  5. Clips supporting and spacing flanged sheets of reflective insulation

    International Nuclear Information System (INIS)

    Carr, R.W.

    1980-01-01

    This invention relates to clips, spacing and supporting flanged sheets of reflective insulation used to encase the main body and associated piping of nuclear reactors to minimize heat and radiation losses. (UK)

  6. Endoscopic removal of over-the-scope clips using a novel cutting device: a retrospective case series.

    Science.gov (United States)

    Schmidt, Arthur; Riecken, Bettina; Damm, Michael; Cahyadi, Oscar; Bauder, Markus; Caca, Karel

    2014-09-01

    Over-the-scope clips (OTSCs; Ovesco Endoscopy, Tübingen, Germany) are extensively used for treatment of gastrointestinal perforations, leakages, fistulas, and bleeding. In this report, a new method of removing OTSCs using a prototype bipolar cutting device is described. A total of 11 patients underwent endoscopic removal of an OTSC. The OTSC was cut at two opposing sites by a prototype device (DC ClipCutter; Ovesco Endoscopy). The remaining clip fragments were extracted using a standard forceps. Mean procedure time was 47 minutes (range 35 - 75 minutes). Cutting of the OTSC at two opposing sites was successful in all cases (100 %). Complete retrieval of all clip fragments was possible in 10 patients (91 %). The overall success rate for cutting and complete removal of the clip was 91 %. No major complications were observed. Removal of OTSCs with the prototype device was feasible and effective. The device may be valuable for OTSC removal in emergency as well as elective indications. © Georg Thieme Verlag KG Stuttgart · New York.

  7. "True" posterior communicating aneurysms: Three cases, three strategies.

    Science.gov (United States)

    Nery, Breno; Araujo, Ricardo; Burjaili, Bruno; Smith, Timothy R; Rodrigues, Jose Carlos; Silva, Marcelo Nery

    2016-01-01

    The authors provide a review of true aneurysms of the posterior communicating artery (PCoA). Three cases admitted in our hospital are presented and discussed as follows. First patient is a 51-year-old female presenting with a Fisher II, Hunt-Hess III (headache and confusion) subarachnoid hemorrhage (SAH) from a ruptured true aneurysm of the right PCoA. She underwent a successful ipsilateral pterional craniotomy for aneurysm clipping and was discharged on postoperative day 4 without neurological deficit. Second patient is a 53-year-old female with a Fisher I, Hunt-Hess III (headache, mild hemiparesis) SAH and multiple aneurisms, one from left ophthalmic carotid artery and one (true) from right PCoA. These lesions were approached and successfully treated by a single pterional craniotomy on the left side. The patient was discharged 4 days after surgery, with complete recovery of muscle strength during follow-up. Third patient is a 69-year-old male with a Fisher III, Hunt-Hess III (headache and confusion) SAH, from a true PCoA on the right. He had a left subclavian artery occlusion with flow theft from the right vertebral artery to the left vertebral artery. The patient underwent endovascular treatment with angioplasty and stent placement on the left subclavian artery that resulted in aneurysm occlusion. In conclusion, despite their seldom occurrence, true PCoA aneurysms can be successfully treated with different strategies.

  8. Turbo Decision Aided Receivers for Clipping Noise Mitigation in Coded OFDM

    Directory of Open Access Journals (Sweden)

    Declercq David

    2008-01-01

    Full Text Available Abstract Orthogonal frequency division multiplexing (OFDM is the modulation technique used in most of the high-rate communication standards. However, OFDM signals exhibit high peak average to power ratio (PAPR that makes them particularly sensitive to nonlinear distortions caused by high-power amplifiers. Hence, the amplifier needs to operate at large output backoff, thereby decreasing the average efficiency of the transmitter. One way to reduce PAPR consists in clipping the amplitude of the OFDM signal introducing an additional noise that degrades the overall system performance. In that case, the receiver needs to set up an algorithm that compensates this clipping noise. In this paper, we propose three new iterative receivers with growing complexity and performance that operate at severe clipping: the first and simplest receiver uses a Viterbi algorithm as channel decoder whereas the other two implement a soft-input soft-output (SISO decoder. Each soft receiver is analyzed through EXIT charts for different mappings. Finally, the performances of the receivers are simulated on both short time-varying channel and AWGN channel.

  9. Turbo Decision Aided Receivers for Clipping Noise Mitigation in Coded OFDM

    Directory of Open Access Journals (Sweden)

    Maxime Colas

    2008-02-01

    Full Text Available Orthogonal frequency division multiplexing (OFDM is the modulation technique used in most of the high-rate communication standards. However, OFDM signals exhibit high peak average to power ratio (PAPR that makes them particularly sensitive to nonlinear distortions caused by high-power amplifiers. Hence, the amplifier needs to operate at large output backoff, thereby decreasing the average efficiency of the transmitter. One way to reduce PAPR consists in clipping the amplitude of the OFDM signal introducing an additional noise that degrades the overall system performance. In that case, the receiver needs to set up an algorithm that compensates this clipping noise. In this paper, we propose three new iterative receivers with growing complexity and performance that operate at severe clipping: the first and simplest receiver uses a Viterbi algorithm as channel decoder whereas the other two implement a soft-input soft-output (SISO decoder. Each soft receiver is analyzed through EXIT charts for different mappings. Finally, the performances of the receivers are simulated on both short time-varying channel and AWGN channel.

  10. A calibration method for proposed XRF measurements of arsenic and selenium in nail clippings

    International Nuclear Information System (INIS)

    Gherase, Mihai R; Fleming, David E B

    2011-01-01

    A calibration method for proposed x-ray fluorescence (XRF) measurements of arsenic and selenium in nail clippings is demonstrated. Phantom nail clippings were produced from a whole nail phantom (0.7 mm thickness, 25 x 25 mm 2 area) and contained equal concentrations of arsenic and selenium ranging from 0 to 20 μg g -1 in increments of 5 μg g -1 . The phantom nail clippings were then grouped in samples of five different masses: 20, 40, 60, 80 and 100 mg for each concentration. Experimental x-ray spectra were acquired for each of the sample masses using a portable x-ray tube and a detector unit. Calibration lines (XRF signal in a number of counts versus stoichiometric elemental concentration) were produced for each of the two elements. A semi-empirical relationship between the mass of the nail phantoms (m) and the slope of the calibration line (s) was determined separately for arsenic and selenium. Using this calibration method, one can estimate elemental concentrations and their uncertainties from the XRF spectra of human nail clippings. (note)

  11. MEASUREMENT OF AFFINITY IN SERUM SAMPLES OF ANTIGEN-FREE, GERM-FREE AND CONVENTIONAL MICE AFTER HYPERIMMUNIZATION WITH 2,4-DINITROPHENYL KEYHOLE LIMPET HEMOCYANIN, USING SURFACE-PLASMON RESONANCE

    NARCIS (Netherlands)

    BAKKER, R; LASONDER, E; BOS, NA

    We previously investigated the primary and secondary responses and hyperimmunization to the T cell-dependent antigen 2,4-dinitrophenyl keyhole limpet hemocyanin (DNP-KLH) in antigen-free (AF), germ-free (GF) and conventional (CV) mice. Both the absolute and relative numbers of DNP-specific

  12. Virus-Clip: a fast and memory-efficient viral integration site detection tool at single-base resolution with annotation capability.

    Science.gov (United States)

    Ho, Daniel W H; Sze, Karen M F; Ng, Irene O L

    2015-08-28

    Viral integration into the human genome upon infection is an important risk factor for various human malignancies. We developed viral integration site detection tool called Virus-Clip, which makes use of information extracted from soft-clipped sequencing reads to identify exact positions of human and virus breakpoints of integration events. With initial read alignment to virus reference genome and streamlined procedures, Virus-Clip delivers a simple, fast and memory-efficient solution to viral integration site detection. Moreover, it can also automatically annotate the integration events with the corresponding affected human genes. Virus-Clip has been verified using whole-transcriptome sequencing data and its detection was validated to have satisfactory sensitivity and specificity. Marked advancement in performance was detected, compared to existing tools. It is applicable to versatile types of data including whole-genome sequencing, whole-transcriptome sequencing, and targeted sequencing. Virus-Clip is available at http://web.hku.hk/~dwhho/Virus-Clip.zip.

  13. Virtual Reality Cerebral Aneurysm Clipping Simulation With Real-time Haptic Feedback

    Science.gov (United States)

    Alaraj, Ali; Luciano, Cristian J.; Bailey, Daniel P.; Elsenousi, Abdussalam; Roitberg, Ben Z.; Bernardo, Antonio; Banerjee, P. Pat; Charbel, Fady T.

    2014-01-01

    Background With the decrease in the number of cerebral aneurysms treated surgically and the increase of complexity of those treated surgically, there is a need for simulation-based tools to teach future neurosurgeons the operative techniques of aneurysm clipping. Objective To develop and evaluate the usefulness of a new haptic-based virtual reality (VR) simulator in the training of neurosurgical residents. Methods A real-time sensory haptic feedback virtual reality aneurysm clipping simulator was developed using the Immersive Touch platform. A prototype middle cerebral artery aneurysm simulation was created from a computed tomography angiogram. Aneurysm and vessel volume deformation and haptic feedback are provided in a 3-D immersive VR environment. Intraoperative aneurysm rupture was also simulated. Seventeen neurosurgery residents from three residency programs tested the simulator and provided feedback on its usefulness and resemblance to real aneurysm clipping surgery. Results Residents felt that the simulation would be useful in preparing for real-life surgery. About two thirds of the residents felt that the 3-D immersive anatomical details provided a very close resemblance to real operative anatomy and accurate guidance for deciding surgical approaches. They believed the simulation is useful for preoperative surgical rehearsal and neurosurgical training. One third of the residents felt that the technology in its current form provided very realistic haptic feedback for aneurysm surgery. Conclusion Neurosurgical residents felt that the novel immersive VR simulator is helpful in their training especially since they do not get a chance to perform aneurysm clippings until very late in their residency programs. PMID:25599200

  14. [Rapid 3-Dimensional Models of Cerebral Aneurysm for Emergency Surgical Clipping].

    Science.gov (United States)

    Konno, Takehiko; Mashiko, Toshihiro; Oguma, Hirofumi; Kaneko, Naoki; Otani, Keisuke; Watanabe, Eiju

    2016-08-01

    We developed a method for manufacturing solid models of cerebral aneurysms, with a shorter printing time than that involved in conventional methods, using a compact 3D printer with acrylonitrile-butadiene-styrene(ABS)resin. We further investigated the application and utility of this printing system in emergency clipping surgery. A total of 16 patients diagnosed with acute subarachnoid hemorrhage resulting from cerebral aneurysm rupture were enrolled in the present study. Emergency clipping was performed on the day of hospitalization. Digital Imaging and Communication in Medicine(DICOM)data obtained from computed tomography angiography(CTA)scans were edited and converted to stereolithography(STL)file formats, followed by the production of 3D models of the cerebral aneurysm by using the 3D printer. The mean time from hospitalization to the commencement of surgery was 242 min, whereas the mean time required for manufacturing the 3D model was 67 min. The average cost of each 3D model was 194 Japanese Yen. The time required for manufacturing the 3D models shortened to approximately 1 hour with increasing experience of producing 3D models. Favorable impressions for the use of the 3D models in clipping were reported by almost all neurosurgeons included in this study. Although 3D printing is often considered to involve huge costs and long manufacturing time, the method used in the present study requires shorter time and lower costs than conventional methods for manufacturing 3D cerebral aneurysm models, thus making it suitable for use in emergency clipping.

  15. [Choledochal lithiasis and stenosis secondary to the migration of a surgical clip].

    Science.gov (United States)

    Baldomà España, M; Pernas Canadell, J C; González Ceballos, S

    2014-01-01

    The migration of a clip to the common bile duct after cholecystectomy is an uncommon, usually late, complication that can lead to diverse complications like stone formation, stenosis, and obstruction in the bile duct. We present the case of a patient who presented with signs and symptoms of cholangitis due to clip migration one year after laparoscopic cholecystectomy; endoscopic retrograde cholangiopancreatography and biliary tract stent placement resolved the problem. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.

  16. Three finger palpation technique of vas deferens for keyhole vasectomy in spotted (Axis axis and sambar deer (Cervus unicolor

    Directory of Open Access Journals (Sweden)

    B. J. William

    2014-09-01

    Full Text Available Aim: Vasectomy is performed in deer for population control, maintain pedigreed animals and prevent inbreeding. Conventional procedure of vasectomy required a long-term anesthesia and longer duration of hospitalization, which often result in stress, morbidity and mortality. A study was conducted to capture, neuter and release the deer with minimal hospitalization and stress by adopting three finger palpation technique of vas deferens and performing vasectomy through a key-hole incision. Materials and Methods: The study was conducted on three spotted male deer and three sambar male deer, which were immobilized with a mixture of xylazine at the dose of 1.00 mg/kg and ketamine at the dose of 5.00 mg/kg. The vas deferens could be palpated as a piece of cooked spaghetti at the neck of the scrotum on the anterior aspect by three finger palpation technique and was able to fix the vas deferens between the thumb and middle finger. Through a key-hole incision of <5 mm length, the vas deferens was exteriorized and resected using electrocautery and the skin incision was sealed with methyl methacrylate. The deer were released on the same day, and no post-operative complication was noticed. Conclusion: The study revealed that three finger palpation technique of vas deferens provided guidance for easy access to vas deferens for vasectomy in deer with less hospitalization, and the deer could be released on the same day.

  17. Origin of fin-clipped salmonids collected at two thermal discharges on Lake Michigan

    International Nuclear Information System (INIS)

    Romberg, G.P.; Thommes, M.M.; Spigarelli, S.A.

    1974-01-01

    Fin clips observed on fish collected during tagging studies at the Point Beach and Waukegan thermal discharges were recorded and the data were tabulated by species. Using fin clip and fish size, attempts were made to identify probable stocking locations and dates from agency records. Data are presented for lake trout, rainbow trout, brown trout, and Coho salmon. Tables are presented to show probable stocking locations and dates

  18. BioClips of symmetric and asymmetric cell division.

    Science.gov (United States)

    Lu, Fong-Mei; Eliceiri, Kevin W; White, John G

    2007-05-01

    Animations have long been used as tools to illustrate complex processes in such diverse fields as mechanical engineering, astronomy, bacteriology and physics. Animations in biology hold particular educational promise for depicting complex dynamic processes, such as photosynthesis, motility, viral replication and cellular respiration, which cannot be easily explained using static two-dimensional images. However, these animations have often been restrictive in scope, having been created for a specific classroom or research audience. In recent years, a new type of animation has emerged called the BioClip (http://www.bioclips.com) that strives to present science in an interactive multimedia format, which is, at once, informative and entertaining, by combining animations, text descriptions and music in one portable cross-platform document. In the present article, we illustrate the educational value of this new electronic resource by reviewing in depth two BioClips our group has created which describe the processes of symmetric and asymmetric cell division (http://www.wormclassroom.org/cb/bioclip).

  19. Effects of Tail Clipping on Larval Performance and Tail Regeneration Rates in the Near Eastern Fire Salamander, Salamandra infraimmaculata.

    Directory of Open Access Journals (Sweden)

    Ori Segev

    Full Text Available Tail-tip clipping is a common technique for collecting tissue samples from amphibian larvae and adults. Surprisingly, studies of this invasive sampling procedure or of natural tail clipping--i.e., bites inflicted by predators including conspecifics--on the performance and fitness of aquatic larval stages of urodeles are scarce. We conducted two studies in which we assessed the effects of posterior tail clipping (~30 percent of tail on Near Eastern fire salamander (Salamandra infraimmaculata larvae. In a laboratory study, we checked regeneration rates of posterior tail-tip clipping at different ages. Regeneration rates were hump-shaped, peaking at the age of ~30 days and then decreasing. This variation in tail regeneration rates suggests tradeoffs in resource allocation between regeneration and somatic growth during early and advanced development. In an outdoor artificial pond experiment, under constant larval densities, we assessed how tail clipping of newborn larvae affects survival to, time to, and size at metamorphosis. Repeated measures ANOVA on mean larval survival per pond revealed no effect of tail clipping. Tail clipping had correspondingly no effect on larval growth and development expressed in size (mass and snout-vent length at, and time to, metamorphosis. We conclude that despite the given variation in tail regeneration rates throughout larval ontogeny, clipping of 30% percent of the posterior tail area seems to have no adverse effects on larval fitness and survival. We suggest that future use of this imperative tool for the study of amphibian should take into account larval developmental stage during the time of application and not just the relative size of the clipped tail sample.

  20. Harmonic Scalpel versus electrocautery and surgical clips in head and neck free-flap harvesting.

    Science.gov (United States)

    Dean, Nichole R; Rosenthal, Eben L; Morgan, Bruce A; Magnuson, J Scott; Carroll, William R

    2014-06-01

    We sought to determine the safety and utility of Harmonic Scalpel-assisted free-flap harvesting as an alternative to a combined electrocautery and surgical clip technique. The medical records of 103 patients undergoing radial forearm free-flap reconstruction (105 free flaps) for head and neck surgical defects between 2006 and 2008 were reviewed. The use of bipolar electrocautery and surgical clips for division of small perforating vessels (n = 53) was compared to ultrasonic energy (Harmonic Scalpel; Ethicon Endo-Surgery, Inc., Cincinnati, Ohio) (n = 52) free-tissue harvesting techniques. Flap-harvesting time was reduced with the use of the Harmonic Scalpel when compared with electrocautery and surgical clip harvest (31.4 vs. 36.9 minutes, respectively; p = 0.06). Two patients who underwent flap harvest with electrocautery and surgical clips developed postoperative donor site hematomas, whereas no donor site complications were noted in the Harmonic Scalpel group. Recipient site complication rates for infection, fistula, and hematoma were similar for both harvesting techniques (p = 0.77). Two flap failures occurred in the clip-assisted radial forearm free-flap harvest group, and none in the Harmonic Scalpel group. Median length of hospitalization was significantly reduced for patients who underwent free-flap harvest with the Harmonic Scalpel when compared with the other technique (7 vs. 8 days; p = 0.01). The Harmonic Scalpel is safe, and its use is feasible for radial forearm free-flap harvest.

  1. Psychophysiological correlates of sexually and non-sexually motivated attention to film clips in a workload task.

    Science.gov (United States)

    Carvalho, Sandra; Leite, Jorge; Galdo-Álvarez, Santiago; Gonçalves, Oscar F

    2011-01-01

    Some authors have speculated that the cognitive component (P3) of the Event-Related Potential (ERP) can function as a psychophysiological measure of sexual interest. The aim of this study was to determine if the P3 ERP component in a workload task can be used as a specific and objective measure of sexual motivation by comparing the neurophysiologic response to stimuli of motivational relevance with different levels of valence and arousal. A total of 30 healthy volunteers watched different films clips with erotic, horror, social-positive and social-negative content, while answering an auditory oddball paradigm. Erotic film clips resulted in larger interference when compared to both the social-positive and auditory alone conditions. Horror film clips resulted in the highest levels of interference with smaller P3 amplitudes than erotic and also than social-positive, social-negative and auditory alone condition. No gender differences were found. Both horror and erotic film clips significantly decreased heart rate (HR) when compared to both social-positive and social-negative films. The erotic film clips significantly increased the skin conductance level (SCL) compared to the social-negative films. The horror film clips significantly increased the SCL compared to both social-positive and social-negative films. Both the highly arousing erotic and non-erotic (horror) movies produced the largest decrease in the P3 amplitude, a decrease in the HR and an increase in the SCL. These data support the notion that this workload task is very sensitive to the attentional resources allocated to the film clip, although they do not act as a specific index of sexual interest. Therefore, the use of this methodology seems to be of questionable utility as a specific measure of sexual interest or as an objective measure of the severity of Hypoactive Sexual Desire Disorder. © 2011 Carvalho et al.

  2. Psychophysiological correlates of sexually and non-sexually motivated attention to film clips in a workload task.

    Directory of Open Access Journals (Sweden)

    Sandra Carvalho

    Full Text Available Some authors have speculated that the cognitive component (P3 of the Event-Related Potential (ERP can function as a psychophysiological measure of sexual interest. The aim of this study was to determine if the P3 ERP component in a workload task can be used as a specific and objective measure of sexual motivation by comparing the neurophysiologic response to stimuli of motivational relevance with different levels of valence and arousal. A total of 30 healthy volunteers watched different films clips with erotic, horror, social-positive and social-negative content, while answering an auditory oddball paradigm. Erotic film clips resulted in larger interference when compared to both the social-positive and auditory alone conditions. Horror film clips resulted in the highest levels of interference with smaller P3 amplitudes than erotic and also than social-positive, social-negative and auditory alone condition. No gender differences were found. Both horror and erotic film clips significantly decreased heart rate (HR when compared to both social-positive and social-negative films. The erotic film clips significantly increased the skin conductance level (SCL compared to the social-negative films. The horror film clips significantly increased the SCL compared to both social-positive and social-negative films. Both the highly arousing erotic and non-erotic (horror movies produced the largest decrease in the P3 amplitude, a decrease in the HR and an increase in the SCL. These data support the notion that this workload task is very sensitive to the attentional resources allocated to the film clip, although they do not act as a specific index of sexual interest. Therefore, the use of this methodology seems to be of questionable utility as a specific measure of sexual interest or as an objective measure of the severity of Hypoactive Sexual Desire Disorder.

  3. Impact of Aneurysm Projection on Intraoperative Complications During Surgical Clipping of Ruptured Posterior Communicating Artery Aneurysms.

    Science.gov (United States)

    Fukuda, Hitoshi; Hayashi, Kosuke; Yoshino, Kumiko; Koyama, Takashi; Lo, Benjamin; Kurosaki, Yoshitaka; Yamagata, Sen

    2016-03-01

    Surgical clipping of ruptured posterior communicating artery (PCoA) aneurysms is a well-established procedure to date. However, preoperative factors associated with procedure-related risk require further elucidation. To investigate the impact of the direction of aneurysm projection on the incidence of procedure-related complications during surgical clipping of ruptured PCoA aneurysms. A total of 65 patients with ruptured PCoA aneurysms who underwent surgical clipping were retrospectively analyzed from a single-center, prospective, observational cohort database in this study. The aneurysms were categorized into lateral and posterior projection groups, depending on direction of the dome. Characteristics and operative findings of each projection group were identified. We also evaluated any correlation of aneurysm projection with the incidence of procedure-related complications. Patients with ruptured PCoA aneurysms with posterior projection more likely presented with good-admission-grade subarachnoid hemorrhage (P = .01, χ test) and were less to also have intracerebral hematoma (P = .01). These aneurysms were found to be associated with higher incidence of intraoperative rupture (P = .02), complex clipping with fenestrated clips (P = .02), and dense adherence to PCoA or its perforators (P = .04) by univariate analysis. Aneurysms with posterior projection were also correlated with procedure-related complications, including postoperative cerebral infarction or hematoma formation (odds ratio, 5.87; 95% confidence interval, 1.11-31.1; P = .04) by multivariable analysis. Ruptured PCoA aneurysms with posterior projection carried a higher risk of procedure-related complications of surgical clipping than those with lateral projection.

  4. Photovoltaic module mounting clip with integral grounding

    Science.gov (United States)

    Lenox, Carl J.

    2010-08-24

    An electrically conductive mounting/grounding clip, usable with a photovoltaic (PV) assembly of the type having an electrically conductive frame, comprises an electrically conductive body. The body has a central portion and first and second spaced-apart arms extending from the central portion. Each arm has first and second outer portions with frame surface-disrupting element at the outer portions.

  5. Interaction of Chelerythrine with Keyhole Limpet Hemocyanin: a Fluorescence Spectroscopy and Molecular Docking Study

    Science.gov (United States)

    Zhong, M.; Long, R. Q.; Wang, Y. H.; Chen, C. L.

    2018-05-01

    The quenching mechanism between chelerythrine (CHE) and keyhole limpet hemocyanin (KLH) was investigated using fluorescence spectroscopy and molecular docking. The experiments were conducted at three different temperatures (293, 298, and 303 K). The results revealed that the intrinsic fluorescence of KLH was strongly quenched by CHE through a static quenching mechanism. The thermodynamic parameters (ΔG, ΔH, and ΔS) of the interaction were calculated, indicating that the interaction between CHE and KLH was spontaneous and that van der Waals forces and hydrogen bond formation played major roles in the binding process. The intrinsic fluorescence of the tyrosine and tryptophan residues in KLH was studied by synchronous fluorescence, which suggested that CHE changed the conformation of KLH. Finally, molecular docking was used to obtain detailed information on the binding sites and binding affinities between CHE and KLH.

  6. Assessment of Invasiveness of the Orange Keyhole Sponge Mycale Armata in Kaneohe Bay, Oahu, Hawaii Based on Surveys 2005-2006, Year 2 of Hawaii Coral Reef Initiative (NODC Accession 0033380)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Orange Keyhole Sponge, Mycale armata Thiele, was unknown in Hawaii prior to 1996. It was first reported in Pearl Harbor and has been reported in low abundance...

  7. Preoperative Computed Tomography-Guided Percutaneous Hookwire Localization of Metallic Marker Clips in the Breast with a Radial Approach: Initial Experience

    Energy Technology Data Exchange (ETDEWEB)

    Uematsu, T.; Kasami, M.; Uchida, Y.; Sanuki, J.; Kimura, K.; Tanaka, K.; Takahashi, K. [Dept. of Diagnostic Radiology, Dept. of Pathology, and Dept. of Breast Surgery, Shizuoka Cancer Center Hospital, Naga-izumi, Shizuoka (Japan)

    2007-07-15

    Background: Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. Purpose: To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Material and Methods: Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. Results: CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). Conclusion: CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.

  8. Preoperative computed tomography-guided percutaneous hookwire localization of metallic marker clips in the breast with a radial approach: initial experience.

    Science.gov (United States)

    Uematsu, T; Kasami, M; Uchida, Y; Sanuki, J; Kimura, K; Tanaka, K; Takahashi, K

    2007-06-01

    Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.

  9. The Cosmic Keyhole How Astronomy Is Unlocking the Secrets of the Universe

    CERN Document Server

    Gater, William J.H

    2009-01-01

    It is 400 years since Galileo first turned the newly invented telescope towards the heavens and saw things that few had ever seen before. His discoveries, along with those of his contemporaries, completely changed our view of the world. Since that time, there have been many revolutions in our understanding of the universe, some perhaps even more revolutionary than the ones from Galileo’s time. In this book, Will Gater leads us through various recent advances in modern astronomy that have increased our understanding of the universe and seen it grow from a single Solar System full of intriguing worlds to a galaxy filled with other star systems and their own planets — maybe even Earthlike worlds. This is a journey like no other. What you glimpse through Gater’s keyhole is vast, breathtakingly beautiful, and sometimes utterly bizarre, certainly unfamiliar to those of us on Terra Firma. From the desolate plains of Mars and the frozen moons of the outer Solar System, from the Milky Way to the ends of the univ...

  10. Patterns and Meanings of English Words through Word Formation Processes of Acronyms, Clipping, Compound and Blending Found in Internet-Based Media

    Directory of Open Access Journals (Sweden)

    Rio Rini Diah Moehkardi

    2017-02-01

    Full Text Available This research aims to explore the word-formation process in English new words found in the internet-based media through acronym, compound,  clipping and blending and their meanings. This study applies Plag’s (2002 framework of acronym and compound; Jamet’s (2009 framework of clipping, and Algeo’s framework (1977 in Hosseinzadeh  (2014 for blending. Despite the  formula established in each respective framework,  there could be occurrences  of novelty and modification on how words are formed and  how meaning developed in  the newly formed words. The research shows that well accepted acronyms can become real words by taking lower case and affixation. Some acronyms initialized non-lexical words, used non initial letters, and used letters and numbers that pronounced the same with the words they represent. Compounding also includes numbers as the element member of the compound. The nominal nouns are likely to have metaphorical and idiomatic meanings. Some compounds evolve to new and more specific meaning. The study also finds that back-clipping is the most dominant clipping. In blending, the sub-category clipping of blending, the study finds out that when clipping takes place, the non-head element is back-clipped and the head is fore-clipped.

  11. Sociolinguistic import of name-clipping among Omambala cultural ...

    African Journals Online (AJOL)

    This study examines the perceived but obvious manifestation of name-clipping among Omambala cultural zone of Anambra State. This situation has given rise to distortion of names and most often, to either mis-interpretation or complete loss of the original and full meanings of the names. This situation of misinterpretation is ...

  12. Using Film Clips to Teach Teen Pregnancy Prevention: "The Gloucester 18" at a Teen Summit

    Science.gov (United States)

    Herrman, Judith W.; Moore, Christopher C.; Anthony, Becky

    2012-01-01

    Teaching pregnancy prevention to large groups offers many challenges. This article describes the use of film clips, with guided discussion, to teach pregnancy prevention. In order to analyze the costs associated with teen pregnancy, a film clip discussion session based with the film "The Gloucester 18" was the keynote of a youth summit. The lesson…

  13. O MONITORAMENTO DE NOTÍCIAS COMO FERRAMENTA PARA A INTELIGÊNCIA COMPETITIVATHE CLIPPING AS TOLL FOR COMPETITIVE INTELLIGENCE

    Directory of Open Access Journals (Sweden)

    Ariane Barbosa Lemos

    2011-07-01

    Full Text Available O artigo apresenta um diagnóstico do serviço de monitoramento de notícias (clipping. No estudo, foram investigados os processos de elaboração desse serviço por uma empresa especializada e sua utilização por parte de organizações dos setores de educação executiva, jurídico e entretenimento. Conclui que tanto a empresa clipadora quanto seus clientes consideram o clipping útil para o processo decisório e o serviço é visto de forma complementar a ação geral de inteligência competitiva das organizações. Palavras-chave inteligência competitiva, monitoramento ambiental, fontes de informação e monitoramento de notícias. Abstract The paper presents a diagnostic study about a clipping service. This study focused the development of the service provided by a specialized firm and its use by organizations operating in the executive education, legal and entertainment areas. It concludes that both the company and your customers consider clipping useful for decision making and the clipping is seen as complementary to general action of competitive intelligence organizations. Keywords competitive intelligence, environmental scanning, information source and clipping.

  14. Effect of hair coat clipping on some physiological changes of dairy bulls

    Directory of Open Access Journals (Sweden)

    Prasanpanich, S.

    2006-03-01

    Full Text Available Some physiological responses of 6 Friesian crossbred (87.5% bull yearling with 2.5 years old, averaging 235 kg. bodyweight were investigated under hot humid conditions. All animals were raised in a house (4 × 15 × 5; w × l × h meters, respectively with concrete floor and were assigned to the Pair Comparison Design according to their weight and age into 2 groups. Animals in group 1 were maintained with their natural hair coat while their counterparts in group 2 were coat clipped fortnightly through a 70-day experimental period. The results indicated that the clipped animals had a significantly (P<0.05 lower sweating rate than did the unclipped ones (102.7±15.48 and 48.3±15.48 g/m2/hour, respectively. However, there were no significant differences in rectal temperature, skin temperature and respiratory rate between the two groups of animals. Further study should be done to clarify the consequences of lower sweating rate in clipped animals under hot humid conditions.

  15. Efficient computation of clipped Voronoi diagram for mesh generation

    KAUST Repository

    Yan, Dongming

    2013-04-01

    The Voronoi diagram is a fundamental geometric structure widely used in various fields, especially in computer graphics and geometry computing. For a set of points in a compact domain (i.e. a bounded and closed 2D region or a 3D volume), some Voronoi cells of their Voronoi diagram are infinite or partially outside of the domain, but in practice only the parts of the cells inside the domain are needed, as when computing the centroidal Voronoi tessellation. Such a Voronoi diagram confined to a compact domain is called a clipped Voronoi diagram. We present an efficient algorithm to compute the clipped Voronoi diagram for a set of sites with respect to a compact 2D region or a 3D volume. We also apply the proposed method to optimal mesh generation based on the centroidal Voronoi tessellation. Crown Copyright © 2011 Published by Elsevier Ltd. All rights reserved.

  16. Efficient computation of clipped Voronoi diagram for mesh generation

    KAUST Repository

    Yan, Dongming; Wang, Wen Ping; Lé vy, Bruno L.; Liu, Yang

    2013-01-01

    The Voronoi diagram is a fundamental geometric structure widely used in various fields, especially in computer graphics and geometry computing. For a set of points in a compact domain (i.e. a bounded and closed 2D region or a 3D volume), some Voronoi cells of their Voronoi diagram are infinite or partially outside of the domain, but in practice only the parts of the cells inside the domain are needed, as when computing the centroidal Voronoi tessellation. Such a Voronoi diagram confined to a compact domain is called a clipped Voronoi diagram. We present an efficient algorithm to compute the clipped Voronoi diagram for a set of sites with respect to a compact 2D region or a 3D volume. We also apply the proposed method to optimal mesh generation based on the centroidal Voronoi tessellation. Crown Copyright © 2011 Published by Elsevier Ltd. All rights reserved.

  17. A Sieving ANN for Emotion-Based Movie Clip Classification

    Science.gov (United States)

    Watanapa, Saowaluk C.; Thipakorn, Bundit; Charoenkitkarn, Nipon

    Effective classification and analysis of semantic contents are very important for the content-based indexing and retrieval of video database. Our research attempts to classify movie clips into three groups of commonly elicited emotions, namely excitement, joy and sadness, based on a set of abstract-level semantic features extracted from the film sequence. In particular, these features consist of six visual and audio measures grounded on the artistic film theories. A unique sieving-structured neural network is proposed to be the classifying model due to its robustness. The performance of the proposed model is tested with 101 movie clips excerpted from 24 award-winning and well-known Hollywood feature films. The experimental result of 97.8% correct classification rate, measured against the collected human-judges, indicates the great potential of using abstract-level semantic features as an engineered tool for the application of video-content retrieval/indexing.

  18. 21 CFR 884.2685 - Fetal scalp clip electrode and applicator.

    Science.gov (United States)

    2010-04-01

    ... and an external monitoring device by means of pinching skin tissue with a nonreusable clip. This... shall have an approved PMA or a declared completed PDP in effect before being placed in commercial...

  19. Direct mounted photovoltaic device with improved front clip

    Science.gov (United States)

    Keenihan, James R; Boven, Michelle; Brown, Jr., Claude; Gaston, Ryan S; Hus, Michael; Langmaid, Joe A; Lesniak, Mike

    2013-11-05

    The present invention is premised upon a photovoltaic assembly system for securing and/or aligning at least a plurality of vertically adjacent (overlapping) photovoltaic device assemblies to one another. The securing function being accomplished by a clip member that may be a separate component or integral to one or more of the photovoltaic device assemblies.

  20. Direct mounted photovoltaic device with improved side clip

    Science.gov (United States)

    Keenihan, James R; Boven, Michelle L; Brown, Jr., Claude; Eurich, Gerald K; Gaston, Ryan S; Hus, Michael

    2013-11-19

    The present invention is premised upon a photovoltaic assembly system for securing and/or aligning at least a plurality of vertically adjacent photovoltaic device assemblies to one another. The securing function being accomplished by a clip member that may be a separate component or integral to one or more of the photovoltaic device assemblies.

  1. Development of a new detection device using a glass clip emitting infrared fluorescence for laparoscopic surgery of gastric cancer

    International Nuclear Information System (INIS)

    Inada, Shunko Albano; Mori, Kensaku; Fuchi, Shingo; Hasegawa, Junichi; Misawa, Kazunari; Nakanishi, Hayao

    2015-01-01

    In conventional method, to identify location of the tumor intraperitoneally for extirpation of the gastric cancer, charcoal ink is injected around the primary tumor. However, in the time of laparoscopic operation, it is difficult to estimate specific site of primary tumor. In this study we developed a glass phosphors was realized with Yb 3+ , Nd 3+ doped to Bi 2 O 3 -B 2 O 3 based glasses, which have central emission wavelength of 1020 nm and 100 nm of FWHM. Using this glass phosphor, we developed a fluorescent clip and the laparoscopic fluorescent detection system for clip-derived near-infrared light. To evaluated clinical performance of a fluorescent clip and the laparoscopic detection system, we used resected stomach from the patients. Fluorescent clip was fixed on the gastric mucosa, and an excitation light (wavelength: 808nm) was irradiated from outside of stomach for detection of fluorescent through stomach wall. As a result, fluorescent emission from the clip was successfully detected. These results indicate that the glass fluorescent clip in combination with laparoscopic detection system is a very useful method to identify the exact location of the primary gastric cancer. (paper)

  2. Real-time surgery simulation of intracranial aneurysm clipping with patient-specific geometries and haptic feedback

    Science.gov (United States)

    Fenz, Wolfgang; Dirnberger, Johannes

    2015-03-01

    Providing suitable training for aspiring neurosurgeons is becoming more and more problematic. The increasing popularity of the endovascular treatment of intracranial aneurysms leads to a lack of simple surgical situations for clipping operations, leaving mainly the complex cases, which present even experienced surgeons with a challenge. To alleviate this situation, we have developed a training simulator with haptic interaction allowing trainees to practice virtual clipping surgeries on real patient-specific vessel geometries. By using specialized finite element (FEM) algorithms (fast finite element method, matrix condensation) combined with GPU acceleration, we can achieve the necessary frame rate for smooth real-time interaction with the detailed models needed for a realistic simulation of the vessel wall deformation caused by the clamping with surgical clips. Vessel wall geometries for typical training scenarios were obtained from 3D-reconstructed medical image data, while for the instruments (clipping forceps, various types of clips, suction tubes) we use models provided by manufacturer Aesculap AG. Collisions between vessel and instruments have to be continuously detected and transformed into corresponding boundary conditions and feedback forces, calculated using a contact plane method. After a training, the achieved result can be assessed based on various criteria, including a simulation of the residual blood flow into the aneurysm. Rigid models of the surgical access and surrounding brain tissue, plus coupling a real forceps to the haptic input device further increase the realism of the simulation.

  3. Prophylactic clipping for the prevention of bleeding following wide-field endoscopic mucosal resection of laterally spreading colorectal lesions: an economic modeling study.

    Science.gov (United States)

    Bahin, Farzan F; Rasouli, Khalid N; Williams, Stephen J; Lee, Eric Y T; Bourke, Michael J

    2016-08-01

    Clinically significant bleeding (CSPEB) is the most common adverse event following endoscopic mucosal resection (EMR) of large sessile and laterally spreading colorectal lesions (LSLs), and is associated with morbidity and resource utilization. CSPEB occurs more frequently with proximal LSLs. Prophylactic clipping of the post-EMR defect may be beneficial in CSPEB prevention. The aim of this study was to determine the cost-effectiveness of a prophylactic clipping strategy. We hypothesized that prophylactic clipping in the proximal colon was cost-effective. An economic model was applied to outcomes from the Australian Colonic Endoscopic Mucosal Resection (ACE) Study. Clip distances of 3, 5, 8, and 10 mm were analyzed. The cost of treating CSPEB was determined from an independent costing agency. The funds needed to spend (FNS) was the cost incurred in order to prevent one episode of CSPEB. A break-even analysis was performed to determine cost equivalence of the costs of clipping and CSPEB. Outcomes of 1717 LSLs (mean size 35.8 mm; 52.6 % proximal colon) that underwent EMR were analyzed. The overall rate of CSPEB was 6.4 % (proximal 8.9 %; distal 3.7 %). Endoscopic management was required in 45 % of CSPEB episodes. With a clip distance of 3 mm, the expected cost of prophylactic clipping was € 1106 per lesion compared with € 157 per lesion for the expected cost of CSPEB without clipping. At 100 % clipping efficacy, the FNS was € 14 826 (proximal and distal lesions € 9309 and € 29 540, respectively). A clip price of € 10.35 was required for the cost of clipping to offset the cost of CSPEB. A prophylactic clipping strategy is not cost-effective and at present cannot be justified for all lesions or selectively for lesions in the proximal colon. ClinicalTrials.gov (NCT01368289). © Georg Thieme Verlag KG Stuttgart · New York.

  4. Practical Use of the Extended No Action Level (eNAL) Correction Protocol for Breast Cancer Patients With Implanted Surgical Clips

    International Nuclear Information System (INIS)

    Penninkhof, Joan; Quint, Sandra; Baaijens, Margreet; Heijmen, Ben; Dirkx, Maarten

    2012-01-01

    Purpose: To describe the practical use of the extended No Action Level (eNAL) setup correction protocol for breast cancer patients with surgical clips and evaluate its impact on the setup accuracy of both tumor bed and whole breast during simultaneously integrated boost treatments. Methods and Materials: For 80 patients, two orthogonal planar kilovoltage images and one megavoltage image (for the mediolateral beam) were acquired per fraction throughout the radiotherapy course. For setup correction, the eNAL protocol was applied, based on registration of surgical clips in the lumpectomy cavity. Differences with respect to application of a No Action Level (NAL) protocol or no protocol were quantified for tumor bed and whole breast. The correlation between clip migration during the fractionated treatment and either the method of surgery or the time elapsed from last surgery was investigated. Results: The distance of the clips to their center of mass (COM), averaged over all clips and patients, was reduced by 0.9 ± 1.2 mm (mean ± 1 SD). Clip migration was similar between the group of patients starting treatment within 100 days after surgery (median, 53 days) and the group starting afterward (median, 163 days) (p = 0.20). Clip migration after conventional breast surgery (closing the breast superficially) or after lumpectomy with partial breast reconstructive techniques (sutured cavity). was not significantly different either (p = 0.22). Application of eNAL on clips resulted in residual systematic errors for the clips’ COM of less than 1 mm in each direction, whereas the setup of the breast was within about 2 mm of accuracy. Conclusions: Surgical clips can be safely used for high-accuracy position verification and correction. Given compensation for time trends in the clips’ COM throughout the treatment course, eNAL resulted in better setup accuracies for both tumor bed and whole breast than NAL.

  5. Does the placement of surgical clips within the excision cavity influence local control for patients treated with breast conserving surgery and irradiation?

    Energy Technology Data Exchange (ETDEWEB)

    Fein, Douglas A; Fowble, Barbara L; Hanlon, Alexandra L; Hoffman, John P; Sigurdson, Elin R; Eisenberg, Burton L

    1995-07-01

    PURPOSE: A number of authors have demonstrated the importance of using surgical clips to define the tumor bed in the treatment planning of early stage breast cancer. The clips have been useful in delineating the borders of the tangential fields especially for very medial and very lateral lesions as well as the boost volume. If surgical clips better define the tumor bed then a reduction in true or marginal recurrences should be appreciated. We sought to compare the incidence of breast recurrence in women with and without surgical clips controlling for other recognized prognostic factors. METHODS AND MATERIALS: Between 1980 and 1992, 1364 women with clinical Stage I or II invasive breast cancer underwent excisional biopsy, axillary dissection, and definitive irradiation. Median follow-up was 60 months. Median age was 55 years. Seventy-one percent of patients were path N0, 22% had 1-3 nodes and 7% had {>=} 4 nodes. Sixty-one percent were ER positive and 49% PR positive. Margin status was negative in 62%, positive in 10%, close in 9%, and unknown in 19%. Fifty-seven percent of women underwent a reexcision. Adjuvant chemotherapy {+-} tamoxifen was administered in 29%, and tamoxifen alone in 17%. Surgical clips were placed in the excision cavity in 556 patients while the other 808 did not have clips placed. All patients had a boost to the tumor bed. Patients had their boost planned with CT scanning or stereo shift radiographs. No significant differences between the 2 groups were noted for median age, T stage, nodal status, race, ER/PR receptor status, region irradiated, or tumor location. Patients without clips had negative margins less often, a higher rate of unknown or positive margins and more often received no adjuvant therapy compared to patients with surgical clips. RESULTS: Twenty-three and 27 patients with and without surgical clips, respectively developed a true or marginal recurrence in the treated breast. The actuarial probability of a breast recurrence was 2

  6. Esophageal Perforation due to Transesophageal Echocardiogram: New Endoscopic Clip Treatment

    Directory of Open Access Journals (Sweden)

    John Robotis

    2014-07-01

    Full Text Available Esophageal perforation due to transesophageal echocardiogram (TEE during cardiac surgery is rare. A 72-year-old female underwent TEE during an operation for aortic valve replacement. Further, the patient presented hematemesis. Gastroscopy revealed an esophageal bleeding ulcer. Endoscopic therapy was successful. Although a CT scan excluded perforation, the patient became febrile, and a second gastroscopy revealed a big perforation at the site of ulcer. The patient's clinical condition required endoscopic intervention with a new OTSC® clip (Ovesco Endoscopy, Tübingen, Germany. The perforation was successfully sealed. The patient remained on intravenous antibiotics, proton pump inhibitors and parenteral nutrition for few days, followed by enteral feeding. She was discharged fully recovered 3 months later. We clearly demonstrate an effective, less invasive treatment of an esophageal perforation with a new endoscopic clip.

  7. Does the placement of surgical clips within the excision cavity influence local control for patients treated with breast conserving surgery and irradiation?

    International Nuclear Information System (INIS)

    Fein, Douglas A.; Fowble, Barbara L.; Hanlon, Alexandra L.; Hoffman, John P.; Sigurdson, Elin R.; Eisenberg, Burton L.

    1995-01-01

    PURPOSE: A number of authors have demonstrated the importance of using surgical clips to define the tumor bed in the treatment planning of early stage breast cancer. The clips have been useful in delineating the borders of the tangential fields especially for very medial and very lateral lesions as well as the boost volume. If surgical clips better define the tumor bed then a reduction in true or marginal recurrences should be appreciated. We sought to compare the incidence of breast recurrence in women with and without surgical clips controlling for other recognized prognostic factors. METHODS AND MATERIALS: Between 1980 and 1992, 1364 women with clinical Stage I or II invasive breast cancer underwent excisional biopsy, axillary dissection, and definitive irradiation. Median follow-up was 60 months. Median age was 55 years. Seventy-one percent of patients were path N0, 22% had 1-3 nodes and 7% had ≥ 4 nodes. Sixty-one percent were ER positive and 49% PR positive. Margin status was negative in 62%, positive in 10%, close in 9%, and unknown in 19%. Fifty-seven percent of women underwent a reexcision. Adjuvant chemotherapy ± tamoxifen was administered in 29%, and tamoxifen alone in 17%. Surgical clips were placed in the excision cavity in 556 patients while the other 808 did not have clips placed. All patients had a boost to the tumor bed. Patients had their boost planned with CT scanning or stereo shift radiographs. No significant differences between the 2 groups were noted for median age, T stage, nodal status, race, ER/PR receptor status, region irradiated, or tumor location. Patients without clips had negative margins less often, a higher rate of unknown or positive margins and more often received no adjuvant therapy compared to patients with surgical clips. RESULTS: Twenty-three and 27 patients with and without surgical clips, respectively developed a true or marginal recurrence in the treated breast. The actuarial probability of a breast recurrence was 2% at

  8. Does the placement of surgical clips within the excision cavity influence local control for patients treated with breast-conserving surgery and irradiation?

    International Nuclear Information System (INIS)

    Fein, Douglas A.; Fowble, Barbara L.; Hanlon, Alexandra L.; Hoffman, John P.; Sigurdson, Elin R.; Eisenberg, Burton L.

    1996-01-01

    Purpose: A number of authors have demonstrated the importance of using surgical clips to define the tumor bed in the treatment planning of early-stage breast cancer. The clips have been useful in delineating the borders of the tangential fields, especially for very medial and very lateral lesions as well as the boost volume. If surgical clips better define the tumor bed, then a reduction in true or marginal recurrences should be appreciated. We sought to compare the incidence of breast recurrence in women with and without surgical clips, controlling for other recognized prognostic factors. Methods and Materials: Between 1980 and 1992, 1364 women with clinical Stage I or II invasive breast cancer underwent excisional biopsy, axillary dissection, and definitive irradiation. Median follow-up was 60 months. Median age was 55 years. Seventy-one percent of patients were path N0, 22% had one to three nodes, and 7% had > four nodes. Sixty-one percent were ER positive and 49% PR positive. Margin status was negative in 62%, positive in 10%, close in 9%, and unknown in 19%. Fifty-seven percent of women underwent a reexcision. Adjuvant chemotherapy + tamoxifen was administered in 29%, and tamoxifen alone in 17%. Surgical clips were placed in the excision cavity in 556 patients, while the other 808 did not have clips placed. All patients had a boost to the tumor bed. Patients had their boost planned with CT scanning or stereo shift radiographs. No significant differences between the two groups were noted for median age, T stage, nodal status, race, ER/PR receptor status, region irradiated, or tumor location. Patients without clips had negative margins less often, a higher rate of unknown or positive margins and more often received no adjuvant therapy compared to patients with surgical clips. Results: Twenty-five and 27 patients with and without surgical clips, respectively, developed a true or marginal recurrence in the treated breast. The actuarial probability of a breast

  9. Efficacy of electrocoagulation in sealing the cystic artery and cystic duct occluded with only one absorbable clip during laparoscopic cholecystectomy.

    Science.gov (United States)

    Yang, Chang-Ping; Cao, Jin-Lin; Yang, Ren-Rong; Guo, Hong-Rong; Li, Zhao-Hui; Guo, Hai-Ying; Shao, Yin-Can; Liu, Gui-Bao

    2014-02-01

    Even though laparoscopic cholecystectomy (LC) emerged over 20 years ago, controversies persist with regard to the best method to ligate the cystic duct and artery. We proposed to assess the effectiveness and safety of electrocoagulation to seal the cystic artery and cystic duct after their occlusion with only one absorbable clip. We retrospectively compared the clinical data for 635 patients undergoing LC using electrocoagulation to seal the cystic artery and cystic duct that were occluded with only one absorbable clip (Group 1) and 728 patients undergoing LC using titanium clips (Group 2). In parallel, 30 rabbits randomized into six groups underwent cholecystectomy. After cystic duct ligation with absorbable or titanium clips, the animals were sacrificed 1, 3, or 6 months later, and intraabdominal adhesions were assessed after celiotomy. The mean operative time was significantly shorter (41.6 versus 58.9 minutes, PElectrocoagulation of the cystic artery and cystic duct that were occluded with only one absorbable clip is safe and effective during LC. This approach is associated with shortened operative times and reduced leakage, compared with the standard method using metal clips.

  10. Effects of Knee Alignments and Toe Clip on Frontal Plane Knee Biomechanics in Cycling.

    Science.gov (United States)

    Shen, Guangping; Zhang, Songning; Bennett, Hunter J; Martin, James C; Crouter, Scott E; Fitzhugh, Eugene C

    2018-06-01

    Effects of knee alignment on the internal knee abduction moment (KAM) in walking have been widely studied. The KAM is closely associated with the development of medial knee osteoarthritis. Despite the importance of knee alignment, no studies have explored its effects on knee frontal plane biomechanics during stationary cycling. The purpose of this study was to examine the effects of knee alignment and use of a toe clip on the knee frontal plane biomechanics during stationary cycling. A total of 32 participants (11 varus, 11 neutral, and 10 valgus alignment) performed five trials in each of six cycling conditions: pedaling at 80 rpm and 0.5 kg (40 Watts), 1.0 kg (78 Watts), and 1.5 kg (117 Watts) with and without a toe clip. A motion analysis system and a customized instrumented pedal were used to collect 3D kinematic and kinetic data. A 3 × 2 × 3 (group × toe clip × workload) mixed design ANOVA was used for statistical analysis (p < 0.05). There were two different knee frontal plane loading patterns, internal abduction and adduction moment, which were affected by knee alignment type. The knee adduction angle was 12.2° greater in the varus group compared to the valgus group (p = 0.001), yet no difference was found for KAM among groups. Wearing a toe clip increased the knee adduction angle by 0.95º (p = 0.005). The findings of this study indicate that stationary cycling may be a safe exercise prescription for people with knee malalignments. In addition, using a toe clip may not have any negative effects on knee joints during stationary cycling.

  11. MRI-validation of SEP monitoring for ischemic events during microsurgical clipping of intracranial aneurysms.

    Science.gov (United States)

    Krayenbühl, Niklaus; Sarnthein, Johannes; Oinas, Minna; Erdem, Eren; Krisht, Ali F

    2011-09-01

    During surgical clipping of intracranial aneurysms, reduction in SEP amplitude is thought to indicate cortical ischemia and subsequent neurological deficits. Since the sensitivity of SEP is questioned, we investigated SEP with respect to post-operative ischemia. In 36 patients with 51 intracranial aneurysms, clinical evaluation and diffusion-weighted MRI (DWI) was performed before and within 24h after surgery. During surgery, time of temporary occlusion was recorded. MRI images were reviewed for signs of ischemia. For 43 clip applications (84%), we observed neither pathologic SEP events nor ischemia in MRI. In two cases where reduction lasted >10 min after clip release, SEP events correlated with ischemia in the MRI. Only one of the ischemic patients was symptomatic and developed a transient hemiparesis. While pathologic SEP events correlated with visible ischemia in MRI only in two cases with late SEP recovery, ischemia in MRI may have been transient or may not have reached detection threshold in the other cases, in agreement with the absence of permanent neurological deficits. In complex aneurysm cases, where prolonged temporary occlusion is expected, SEP should be used to detect ischemia at a reversible stage to improve the safety of aneurysm clipping. Copyright © 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  12. Custom-made different designs of pressure clips for the management of ear lobe keloids

    Directory of Open Access Journals (Sweden)

    Anshul Chugh

    2013-01-01

    Full Text Available Introduction : Keloids are frequent finding after physical trauma. Keloids of ear lobe are common complication of ear piercing, although its incidence remains unknown. The use of intrakeloid resection and a form pressure device to treat pinna keloids. The recommendation of this therapy is to maintain constant pressure and duration of pressure therapy was about 25 weeks. Clinical innovation : This article will present inexpensive custom made pressure clips of various designs. The dimensions of polymethylmethacrylate (PMMA plates in ear lobe clip presented by us though they esthetically not so good, but colored PMMA has been used to make it decorative and acceptable by most of the patients. This has been an encouraging experience to use the different designs. Discussion : Ear clip prosthesis has been developed for maintaining pressure on ear lobe keloids before and after surgical removal. The prosthesis includes an ear clip to which heat-polymerized acrylic resin is attached, which covers the keloid area. Pressure therapy is widely used to help in the early maturation of scar tissue and to prevent the recurrence of keloid. The preliminary report by Brent revealed that constant light pressure was an effective means of preventing post excision recurrence of ear lobe keloids using a decorative, spring-pressure earring.

  13. Evaluation of stiffness and plastic deformation of active ceramic self-ligating bracket clips after repetitive opening and closure movements.

    Science.gov (United States)

    Carneiro, Grace Kelly Martins; Roque, Juliano Alves; Segundo, Aguinaldo Silva Garcez; Suzuki, Hideo

    2015-01-01

    The aim of this study was to assess whether repetitive opening and closure of self-ligating bracket clips can cause plastic deformation of the clip. Three types of active/interactive ceramic self-ligating brackets (n = 20) were tested: In-Ovation C, Quicklear and WOW. A standardized controlled device performed 500 cycles of opening and closure movements of the bracket clip with proper instruments and techniques adapted as recommended by the manufacturer of each bracket type. Two tensile tests, one before and one after the repetitive cycles, were performed to assess the stiffness of the clips. To this end, a custom-made stainless steel 0.40 x 0.40 mm wire was inserted into the bracket slot and adapted to the universal testing machine (EMIC DL2000), after which measurements were recorded. On the loading portion of the loading-unloading curve of clips, the slope fitted a first-degree equation curve to determine the stiffness/deflection rate of the clip. The results of plastic deformation showed no significant difference among bracket types before and after the 500 cycles of opening and closure (p = 0.811). There were significant differences on stiffness among the three types of brackets (p = 0.005). The WOW bracket had higher mean values, whereas Quicklear bracket had lower values, regardless of the opening/closure cycle. Repetitive controlled opening and closure movements of the clip did not alter stiffness or cause plastic deformation.

  14. Evaluation of stiffness and plastic deformation of active ceramic self-ligating bracket clips after repetitive opening and closure movements

    Directory of Open Access Journals (Sweden)

    Grace Kelly Martins Carneiro

    2015-08-01

    Full Text Available OBJECTIVE: The aim of this study was to assess whether repetitive opening and closure of self-ligating bracket clips can cause plastic deformation of the clip.METHODS: Three types of active/interactive ceramic self-ligating brackets (n = 20 were tested: In-Ovation C, Quicklear and WOW. A standardized controlled device performed 500 cycles of opening and closure movements of the bracket clip with proper instruments and techniques adapted as recommended by the manufacturer of each bracket type. Two tensile tests, one before and one after the repetitive cycles, were performed to assess the stiffness of the clips. To this end, a custom-made stainless steel 0.40 x 0.40 mm wire was inserted into the bracket slot and adapted to the universal testing machine (EMIC DL2000, after which measurements were recorded. On the loading portion of the loading-unloading curve of clips, the slope fitted a first-degree equation curve to determine the stiffness/deflection rate of the clip.RESULTS: The results of plastic deformation showed no significant difference among bracket types before and after the 500 cycles of opening and closure (p = 0.811. There were significant differences on stiffness among the three types of brackets (p = 0.005. The WOW bracket had higher mean values, whereas Quicklear bracket had lower values, regardless of the opening/closure cycle.CONCLUSION: Repetitive controlled opening and closure movements of the clip did not alter stiffness or cause plastic deformation.

  15. Emotion Index of Cover Song Music Video Clips based on Facial Expression Recognition

    DEFF Research Database (Denmark)

    Kavallakis, George; Vidakis, Nikolaos; Triantafyllidis, Georgios

    2017-01-01

    This paper presents a scheme of creating an emotion index of cover song music video clips by recognizing and classifying facial expressions of the artist in the video. More specifically, it fuses effective and robust algorithms which are employed for expression recognition, along with the use...... of a neural network system using the features extracted by the SIFT algorithm. Also we support the need of this fusion of different expression recognition algorithms, because of the way that emotions are linked to facial expressions in music video clips....

  16. Clinical outcome of critically ill, not fully recompensated, patients undergoing MitraClip therapy

    DEFF Research Database (Denmark)

    Rudolph, Volker; Huntgeburth, Michael; von Bardeleben, Ralph Stephan

    2014-01-01

    AIMS: As periprocedural risk is low, MitraClip implantation is often performed in critically ill, not fully recompensated patients, who are in NYHA functional class IV at the time of the procedure, to accelerate convalescence. We herein sought to evaluate the procedural and 30-day outcome.......3%. CONCLUSION: MitraClip therapy is feasible and safe even in critically ill, not fully recompensated patients and leads to symptomatic improvement in over two-thirds of these patients; however, it is associated with an elevated 30-day mortality....

  17. Top-down and Middle-down Protein Analysis Reveals that Intact and Clipped Human Histones Differ in Post-translational Modification Patterns

    DEFF Research Database (Denmark)

    Tvardovskiy, Andrey; Wrzesinski, Krzysztof; Sidoli, Simone

    2015-01-01

    Post-translational modifications (PTMs) of histone proteins play a fundamental role in regulation of DNA-templated processes. There is also growing evidence that proteolytic cleavage of histone N-terminal tails, known as histone clipping, influences nucleosome dynamics and functional properties...... hepatocytes and the hepatocellular carcinoma cell line HepG2/C3A when grown in spheroid (3D) culture, but not in a flat (2D) culture. Using tandem mass spectrometry we localized four different clipping sites in H3 and one clipping site in H2B. We show that in spheroid culture clipped H3 proteoforms are mainly...

  18. [MitraClip® for treatment of tricuspid valve insufficiency].

    Science.gov (United States)

    Pfister, R; Baldus, S

    2017-11-01

    Tricuspid valve regurgitation is frequently found as a result of right ventricular remodeling due to advanced left heart diseases. Drug treatment is limited to diuretics and the cardiac or pulmonary comorbidities. Due to the high risk only a small percentage of patients are amenable to surgical treatment of tricuspid regurgitation in those who undergo left-sided surgery for other reasons. Catheter-based procedures are an attractive treatment alternative, particularly since the strong prognostic impact of tricuspid regurgitation suggests an unmet need of treatment, independent of the underlying heart disease. A vast amount of clinical experience exists for the MitraClip system for treatment of mitral regurgitation. A first case series shows that the application for treatment of tricuspid regurgitation is technically feasible, seems to be safe and the degree of valve regurgitation can be reduced. In this review the background of tricuspid regurgitation treatment is summarized and first experiences and perspectives with the MitraClip system are assessed.

  19. Surgical clips for position verification and correction of non-rigid breast tissue in simultaneously integrated boost (SIB) treatments

    International Nuclear Information System (INIS)

    Penninkhof, Joan; Quint, Sandra; Boer, Hans de; Mens, Jan Willem; Heijmen, Ben; Dirkx, Maarten

    2009-01-01

    Background and purpose: The aim of this study is to investigate whether surgical clips in the lumpectomy cavity are representative for position verification of both the tumour bed and the whole breast in simultaneously integrated boost (SIB) treatments. Materials and methods: For a group of 30 patients treated with a SIB technique, kV and MV planar images were acquired throughout the course of the fractionated treatment. The 3D set-up error for the tumour bed was derived by matching the surgical clips (3-8 per patient) in two almost orthogonal planar kV images. By projecting the 3D set-up error derived from the planar kV images to the (u, v)-plane of the tangential beams, the correlation with the 2D set-up error for the whole breast, derived from the MV EPID images, was determined. The stability of relative clip positions during the fractionated treatment was investigated. In addition, for a subgroup of 15 patients, the impact of breathing was determined from fluoroscopic movies acquired at the linac. Results: The clip configurations were stable over the course of radiotherapy, showing an inter-fraction variation (1 SD) of 0.5 mm on average. Between the start and the end of the treatment, the mean distance between the clips and their center of mass was reduced by 0.9 mm. A decrease larger than 2 mm was observed in eight patients (17 clips). The top-top excursion of the clips due to breathing was generally less than 2.5 mm in all directions. The population averages of the difference (±1 SD) between kV and MV matches in the (u, v)-plane were 0.2 ± 1.8 mm and 0.9 ± 1.5 mm, respectively. In 30% of the patients, time trends larger than 3 mm were present over the course of the treatment in either or in both kV and MV match results. Application of the NAL protocol based on the clips reduced the population mean systematic error to less than 2 mm in all directions, both for the tumour bed and the whole breast. Due to the observed time trends, these systematic errors can

  20. Aneurysmal subarachnoid hemorrhage: outcome of aneurysm clipping versus coiling in anterior circulation aneurysm

    International Nuclear Information System (INIS)

    Wadd, I.H.; Haroon, A.; Ansari, S.

    2015-01-01

    To compare the neurological outcome of microsurgical clipping versus coiling in patients with anterior circulation aneurysm. Study Design: Comparative study. Place and Duration of Study: Department of Neurosurgery, Lahore General Hospital, Lahore, from January 2010 to December 2013. Methodology: Patients aged 14 - 60 years, with ruptured cerebral aneurysm of anterior circulation and World Federation of Neurosurgical Society (WFNS) grades 1, 2 and 3 were included. Patients more than 60 years, medically unfit patient and posterior circulation aneurysms and WFNS grades 4 and 5 were excluded. Aneurysm sac obliteration was done in randomized manner with microsurgical clipping or coiling. Postoperatively, the patients were assessed and followed-up upto one year for outcome parameters on the bases of WFNS grade and Modified Ranking Scale (mRS) as favourable (mRS =2 ) and unfavourable (mRS > 2). Results: Among 140 subjects selected for study, 70 were included in group A, i.e. coiling and other 70 were in group B, i.e. clipping. The median age of patients in group A was 52.5 ± 10 years and in group B was 51.00 ± years. Overall, 56 (40%) males, 28 (60%) males in each group; and 84 (60%) females, 42 (60%) in each group were included. The male to female ratio in this study was 1:1.5. In group A, i.e. coiling, 27 (38.6%) patients had no disability (grades 1 and 2), 25 (35.7%) were slightly disabled (grade 3) and 18 (25.7%) had moderate disability (grade 4); whereas in group B, i.e. clipping group 23 (32.9%) patients had no disability (grades 1 and 2), 23 (32.9%) were slightly disabled (grade 3) and 24 (34.3%) had moderate disability (grade 4). At one year follow-up, in group A, favourable outcome was achieved in 56 (80%) of patients compared to 48 (68.6%) in group B; whilst, 14 (20%) patients in group A and 22 (33.1%) in group B showed unfavourable outcome. Although mortality rate was higher in clipping (n=3, 4.3%) as compared to coiling (n=1, 1.4%), but was not statistically

  1. Combining monoenergetic extrapolations from dual-energy CT with iterative reconstructions. Reduction of coil and clip artifacts from intracranial aneurysm therapy

    Energy Technology Data Exchange (ETDEWEB)

    Winklhofer, Sebastian; Baltsavias, Gerasimos; Michels, Lars; Valavanis, Antonios [University of Zurich, Department of Neuroradiology, University Hospital Zurich, Zurich (Switzerland); Hinzpeter, Ricarda; Stocker, Daniel; Alkadhi, Hatem [University of Zurich, Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich (Switzerland); Burkhardt, Jan-Karl; Regli, Luca [University of Zurich, Department of Neurosurgery, University Hospital Zurich, Zurich (Switzerland)

    2018-03-15

    To compare and to combine iterative metal artifact reduction (MAR) and virtual monoenergetic extrapolations (VMEs) from dual-energy computed tomography (DECT) for reducing metal artifacts from intracranial clips and coils. Fourteen clips and six coils were scanned in a phantom model with DECT at 100 and 150SnkVp. Four datasets were reconstructed: non-corrected images (filtered-back projection), iterative MAR, VME from DECT at 120 keV, and combined iterative MAR + VME images. Artifact severity scores and visibility of simulated, contrast-filled, adjacent vessels were assessed qualitatively and quantitatively by two independent, blinded readers. Iterative MAR, VME, and combined iterative MAR + VME resulted in a significant reduction of qualitative (p < 0.001) and quantitative clip artifacts (p < 0.005) and improved the visibility of adjacent vessels (p < 0.05) compared to non-corrected images, with lowest artifact scores found in combined iterative MAR + VME images. Titanium clips demonstrated less artifacts than Phynox clips (p < 0.05), and artifact scores increased with clip size. Coil artifacts increased with coil size but were reducible when applying iterative MAR + VME compared to non-corrected images. However, no technique improved the severe artifacts from large, densely packed coils. Combining iterative MAR with VME allows for an improved metal artifact reduction from clips and smaller, loosely packed coils. Limited value was found for large and densely packed coils. (orig.)

  2. Determination of moulting events in rock lobsters from pleopod clipping.

    Science.gov (United States)

    Gardner, Caleb; Mills, David J

    2013-01-01

    Rock lobster growth is routinely measured for research to optimise management measures such as size limits and quotas. The process of estimating growth is complicated in crustaceans as growth only occurs when the animal moults. As data are typically collected by tag-recapture methods, the timing of moulting events can bias results. For example, if annual moulting events take place within a very short time-at-large after tagging, or if time-at-large is long and no moulting occurs. Classifying data into cases where moulting has / has not occurred during time-at-large can be required and can generally be determined by change in size between release and recapture. However, in old or slow growth individuals the moult increment can be too small to provide surety that moulting has occurred. A method that has been used since the 1970's to determine moulting in rock lobsters involves clipping the distal portion of a pleopod so that any regeneration observed at recapture can be used as evidence of a moult. We examined the use of this method in both tank and long-duration field trials within a marine protected area, which provided access to large animals with smaller growth increments. Our results emphasised that determination of moulting by change in size was unreliable with larger lobsters and that pleopod clipping can assist in identifying moulting events. However, regeneration was an unreliable measure of moulting if clipping occurred less than three months before the moult.

  3. Determination of moulting events in rock lobsters from pleopod clipping.

    Directory of Open Access Journals (Sweden)

    Caleb Gardner

    Full Text Available Rock lobster growth is routinely measured for research to optimise management measures such as size limits and quotas. The process of estimating growth is complicated in crustaceans as growth only occurs when the animal moults. As data are typically collected by tag-recapture methods, the timing of moulting events can bias results. For example, if annual moulting events take place within a very short time-at-large after tagging, or if time-at-large is long and no moulting occurs. Classifying data into cases where moulting has / has not occurred during time-at-large can be required and can generally be determined by change in size between release and recapture. However, in old or slow growth individuals the moult increment can be too small to provide surety that moulting has occurred. A method that has been used since the 1970's to determine moulting in rock lobsters involves clipping the distal portion of a pleopod so that any regeneration observed at recapture can be used as evidence of a moult. We examined the use of this method in both tank and long-duration field trials within a marine protected area, which provided access to large animals with smaller growth increments. Our results emphasised that determination of moulting by change in size was unreliable with larger lobsters and that pleopod clipping can assist in identifying moulting events. However, regeneration was an unreliable measure of moulting if clipping occurred less than three months before the moult.

  4. Effects of Knee Alignments and Toe Clip on Frontal Plane Knee Biomechanics in Cycling

    Science.gov (United States)

    Shen, Guangping; Zhang, Songning; Bennett, Hunter J.; Martin, James C.; Crouter, Scott E.; Fitzhugh, Eugene C.

    2018-01-01

    Effects of knee alignment on the internal knee abduction moment (KAM) in walking have been widely studied. The KAM is closely associated with the development of medial knee osteoarthritis. Despite the importance of knee alignment, no studies have explored its effects on knee frontal plane biomechanics during stationary cycling. The purpose of this study was to examine the effects of knee alignment and use of a toe clip on the knee frontal plane biomechanics during stationary cycling. A total of 32 participants (11 varus, 11 neutral, and 10 valgus alignment) performed five trials in each of six cycling conditions: pedaling at 80 rpm and 0.5 kg (40 Watts), 1.0 kg (78 Watts), and 1.5 kg (117 Watts) with and without a toe clip. A motion analysis system and a customized instrumented pedal were used to collect 3D kinematic and kinetic data. A 3 × 2 × 3 (group × toe clip × workload) mixed design ANOVA was used for statistical analysis (p < 0.05). There were two different knee frontal plane loading patterns, internal abduction and adduction moment, which were affected by knee alignment type. The knee adduction angle was 12.2° greater in the varus group compared to the valgus group (p = 0.001), yet no difference was found for KAM among groups. Wearing a toe clip increased the knee adduction angle by 0.95º (p = 0.005). The findings of this study indicate that stationary cycling may be a safe exercise prescription for people with knee malalignments. In addition, using a toe clip may not have any negative effects on knee joints during stationary cycling. Key points Varus or valgus alignment did not cause increased frontal-plane knee joint loading, suggesting stationary cycling is a safe exercise. This study supports that using a toe clip did not lead to abnormal frontal-plane knee loading during stationary cycling. Two different knee frontal plane loading patterns, knee abduction and adduction moment, were observed during stationary cycling, which are likely affected by

  5. CLIP-seq analysis of multi-mapped reads discovers novel functional RNA regulatory sites in the human transcriptome.

    Science.gov (United States)

    Zhang, Zijun; Xing, Yi

    2017-09-19

    Crosslinking or RNA immunoprecipitation followed by sequencing (CLIP-seq or RIP-seq) allows transcriptome-wide discovery of RNA regulatory sites. As CLIP-seq/RIP-seq reads are short, existing computational tools focus on uniquely mapped reads, while reads mapped to multiple loci are discarded. We present CLAM (CLIP-seq Analysis of Multi-mapped reads). CLAM uses an expectation-maximization algorithm to assign multi-mapped reads and calls peaks combining uniquely and multi-mapped reads. To demonstrate the utility of CLAM, we applied it to a wide range of public CLIP-seq/RIP-seq datasets involving numerous splicing factors, microRNAs and m6A RNA methylation. CLAM recovered a large number of novel RNA regulatory sites inaccessible by uniquely mapped reads. The functional significance of these sites was demonstrated by consensus motif patterns and association with alternative splicing (splicing factors), transcript abundance (AGO2) and mRNA half-life (m6A). CLAM provides a useful tool to discover novel protein-RNA interactions and RNA modification sites from CLIP-seq and RIP-seq data, and reveals the significant contribution of repetitive elements to the RNA regulatory landscape of the human transcriptome. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  6. SU-E-J-64: Feasibility Study of Surgical Clips for Fiducial Tracking in CyberKnife System

    International Nuclear Information System (INIS)

    Lee, H; Yoon, J; Lee, E; Cho, S; Park, K; Choi, W; Baek, J; Keum, K; Koom, W

    2015-01-01

    Purpose: To investigate the ability of CyberKnife to track surgical clips used as fiducial markers. Methods: The Octavius 1000SRS detector and solid water (RW3) slab phantom were used with motion platform to evaluate the study. The RW3 slab phantom was set up to measure the dose distribution from coronal plane. It consists of 9 plates and the thickness of each plate is 10mm. Among them, one plate was attached with 3 surgical clips, which are orthogonally positioned on outer region of array. The length of attached clip was represented as 1cm on planning CT. The clip plate was placed on the 1000SRS detector and 3 slabs were stacked up on the plate to build the measuring depth. Below the detector, 5 slabs were set. The two-axis motion platform was programmed with 1D sinusoidal movement (20mm peak-to-peak, 3s period) toward superior/inferior and left/right directions to simulate target motion. During delivery, two clips were extracted by two X-ray imagers, which led to translational error correction only. Synchrony was also used for dynamic tracking. After the irradiation, the measured dose distribution of coronal plane was compared with the planar dose distribution calculated by the CyberKnife treatment planning system (Multiplan) for cross verification. The results were assessed by comparing the absolute Gamma (γ) index. Results: The dose distributions measured by the 1000SRS detector were in good agreements with those calculated by Multiplan. In the dosimetric comparison using γ-function criteria based on the distance-to-agreement of 3mm and the local dose difference of 3%, the passing rate with γ- parameter ≤1 was 91% in coronal plane. Conclusion: The surgical clips can be considered as new fiducials for robotic radiosurgery delivery by considering the target margin with less than 5mm

  7. Biochemical Analysis Reveals the Multifactorial Mechanism of Histone H3 Clipping by Chicken Liver Histone H3 Protease

    KAUST Repository

    Chauhan, Sakshi; Mandal, Papita; Tomar, Raghuvir S.

    2016-01-01

    Proteolytic clipping of histone H3 has been identified in many organisms. Despite several studies, the mechanism of clipping, the substrate specificity, and the significance of this poorly understood epigenetic mechanism are not clear. We have

  8. Melt pool and keyhole behaviour analysis for deep penetration laser welding

    International Nuclear Information System (INIS)

    Fabbro, R

    2010-01-01

    One usually defines the main characteristic of the welding performances of a given laser system by its 'penetration curve' that corresponds to the welding depth as a function of the welding speed V w for a given set of operating parameters. Analysis of a penetration curve is interesting and gives very fruitful results. Coupled with high-speed video imaging of melt pool surface and ejected plume behaviour, the analysis of this penetration curve on a very large range of welding speeds, typically from 0 to 50 m min -1 , has allowed us to observe very different and characteristic regimes. These regimes are mainly characterized by the physical processes by which they impede the laser beam penetration inside the material. We show that it is only at rather high welding speeds that these limiting processes are reduced. Consequently, the scaling law of welding depth with welding speed is in agreement with adapted modelling of this process. On the other hand, as the welding speed is reduced, different effects depending on the weld pool dynamics and plume interaction strongly disturb the keyhole stability and are responsible for the deviation of the penetration curve from the previous modelling that agrees with a 1/V w scaling law. A corresponding criterion for the occurrence of this effect is defined.

  9. CLIPS based decision support system for water distribution networks

    Directory of Open Access Journals (Sweden)

    K. Sandeep

    2011-10-01

    Full Text Available The difficulty in knowledge representation of a water distribution network (WDN problem has contributed to the limited use of artificial intelligence (AI based expert systems (ES in the management of these networks. This paper presents a design of a Decision Support System (DSS that facilitates "on-demand'' knowledge generation by utilizing results of simulation runs of a suitably calibrated and validated hydraulic model of an existing aged WDN corresponding to emergent or even hypothetical but likely scenarios. The DSS augments the capability of a conventional expert system by integrating together the hydraulic modelling features with heuristics based knowledge of experts under a common, rules based, expert shell named CLIPS (C Language Integrated Production System. In contrast to previous ES, the knowledge base of the DSS has been designed to be dynamic by superimposing CLIPS on Structured Query Language (SQL. The proposed ES has an inbuilt calibration module that enables calibration of an existing (aged WDN for the unknown, and unobservable, Hazen-Williams C-values. In addition, the daily run and simulation modules of the proposed ES further enable the CLIPS inference engine to evaluate the network performance for any emergent or suggested test scenarios. An additional feature of the proposed design is that the DSS integrates computational platforms such as MATLAB, open source Geographical Information System (GIS, and a relational database management system (RDBMS working under the umbrella of the Microsoft Visual Studio based common user interface. The paper also discusses implementation of the proposed framework on a case study and clearly demonstrates the utility of the application as an able aide for effective management of the study network.

  10. Clinical observation of Artisan iris-clip intraocular lens implantation at stage Ⅰ

    Directory of Open Access Journals (Sweden)

    Qing Zhou

    2014-09-01

    Full Text Available AIM: To observe the clinical efficacy of Artisan iris-clip intraocular lens(IOLimplantation on cataract with a wide range of lens dislocation.METHODS: Twenty-four hospital patients(28 eyesof cataract with lens subluxation by trauma(20 patients, 20 eyesand Marfan's syndrome(4 patients, 8 eyesduring May 2007 to December 2011 were selected. All of them underwent phacoemulsification or an anterior vitrectomy and Artisan iris-clip IOL implantation at stage Ⅰ. Postoperative visual acuity, corneal endothelial cell count, intraocular lens position and postoperative complications were observed. Follow-up time was 6mo.RESULTS:Compared with the preoperative, postoperative best corrected visual acuity improved to varying degrees, visual acuity of 0.1-0.5 was in 20 eyes, 0.5-1.0 in 8 eyes. After followed up 1-6mo, no artificial lens shift, iris inflammation, iris atrophy and corneal decompensation and other complications were observed.CONCLUSION: Cataract surgery with a wide range of lens dislocation is difficult, but as long as surgeons who have a wealth of clinical experience and superb skills, still can carry out phacoemulsification surgery or anterior vitrectomy and Artisan iris-clip IOL implantation and obtain a better outcome.

  11. Clipping of tumour resection margins allows accurate target volume delineation in head and neck cancer adjuvant radiation therapy

    International Nuclear Information System (INIS)

    Bittermann, Gido; Wiedenmann, Nicole; Bunea, Andrei; Schwarz, Steffen J.; Grosu, Anca-L.; Schmelzeisen, Rainer; Metzger, Marc C.

    2015-01-01

    Background: Accurate tumour bed localisation is a key requirement for adjuvant radiotherapy. A new procedure is described for head and neck cancer treatment that improves tumour bed localisation using titanium clips. Materials and methods: Following complete local excision of the primary tumour, the tumour bed was marked with titanium clips. Preoperative gross target volume (GTV) and postoperative tumour bed were examined and the distances between the centres of gravity were evaluated. Results: 49 patients with squamous cell carcinoma of the oral cavity were prospectively enrolled in this study. All patients underwent tumour resection, neck lymph node dissection and defect reconstruction in one stage. During surgery, 7–49 clips were placed in the resection cavity. Surgical clip insertion was successful in 88% (n = 43). Clip identification and tumour bed delineation was successful in all 43 patients. The overall distance between the centres of gravity of the preoperative tumour extension to the tumour bed was 0.9 cm. A significant relationship between the preoperative tumour extension and the postoperative tumour bed volume could be demonstrated. Conclusion: We demonstrate a precise delineation of the former tumour cavity. Improvements in tumour bed delineation allow an increase of accuracy for adjuvant treatment

  12. A Systematic Review and Meta-Analysis on Economic Comparison Between Endovascular Coiling Versus Neurosurgical Clipping for Ruptured Intracranial Aneurysms.

    Science.gov (United States)

    Zhang, Xiaoxi; Li, Li; Hong, Bo; Xu, Yi; Liu, Yuan; Huang, Qinghai; Liu, Jianmin

    2018-05-01

    Healthcare expenditures and cost reduction have been under critical surveillance in all countries and are critical for policymakers. This review aims at qualitatively and quantitatively analyzing the difference of hospital costs and length of stay between endovascular coiling versus neurosurgical clipping in ruptured intracranial aneurysms (RAs). MEDLINE, the Cochrane database, Embase, and the Web of Science database were searched and evaluated independently by 2 authors according to the Newcastle-Ottawa Scale for cohort studies describing economic hospital cost or length of stay in patients with RAs. A total of 8 studies were included, describing 24,219 RAs treated with neurosurgical clipping and 24,962 RAs with endovascular coiling. Meta-analysis revealed that the total hospital costs (THCs) were similar between coiling versus clipping in RAs (standard mean difference [SMD], -0.05; 95% confidence interval [CI], -0.12 to 0.22; I 2  = 99%; P = 0.50). Subgroup analysis showed that THCs of clipping and coiling were similar in ruptured aneurysms in the United States. However, in South Korea, the THCs of coiling were significantly higher than clipping. In the long run, 1-year medical costs of endovascular treatment were significantly lower than that of clipping in RAs (SMD, 0.15; 95% CI, 0.05-0.25; I 2  = 66%; P = 0.005). In addition, the length of stay of coiled patients was significantly shorter than clipped patients (SMD, 0.29; 95% CI, 0.13-0.45; I 2  = 96%; P China, coiling was more expensive. The length of stay was much shorter in coiled patients in all countries. Copyright © 2018. Published by Elsevier Inc.

  13. The source parameters of 2013 Mw6.6 Lushan earthquake constrained with the restored local clipped seismic waveforms

    Science.gov (United States)

    Hao, J.; Zhang, J. H.; Yao, Z. X.

    2017-12-01

    We developed a method to restore the clipped seismic waveforms near epicenter using projection onto convex sets method (Zhang et al, 2016). This method was applied to rescue the local clipped waveforms of 2013 Mw 6.6 Lushan earthquake. We restored 88 out of 93 clipped waveforms of 38 broadband seismic stations of China Earthquake Networks (CEN). The epicenter distance of the nearest station to the epicenter that we can faithfully restore is only about 32 km. In order to investigate if the source parameters of earthquake could be determined exactly with the restored data, restored waveforms are utilized to get the mechanism of Lushan earthquake. We apply the generalized reflection-transmission coefficient matrix method to calculate the synthetic seismic records and simulated annealing method in inversion (Yao and Harkrider, 1983; Hao et al., 2012). We select 5 stations of CEN with the epicenter distance about 200km whose records aren't clipped and three-component velocity records are used. The result shows the strike, dip and rake angles of Lushan earthquake are 200o, 51o and 87o respectively, hereinafter "standard result". Then the clipped and restored seismic waveforms are applied respectively. The strike, dip and rake angles of clipped seismic waveforms are 184o, 53o and 72o respectively. The largest misfit of angle is 16o. In contrast, the strike, dip and rake angles of restored seismic waveforms are 198o, 51o and 87o respectively. It is very close to the "standard result". We also study the rupture history of Lushan earthquake constrained with the restored local broadband and teleseismic waves based on finite fault method (Hao et al., 2013). The result consists with that constrained with the strong motion and teleseismic waves (Hao et al., 2013), especially the location of the patch with larger slip. In real-time seismology, determining the source parameters as soon as possible is important. This method will help us to determine the mechanism of earthquake

  14. Postoperative three-dimensional CT angiography after cerebral aneurysm clipping with titanium clips: detection with single detector CT. Comparison with intra-arterial digital subtraction angiography

    International Nuclear Information System (INIS)

    Sakuma, I.; Tomura, N.; Kinouchi, H.; Takahashi, S.; Otani, T.; Watarai, J.; Mizoi, K.

    2006-01-01

    AIM: To assess the significance of three-dimensional computed tomography angiography (3D-CTA) in detecting remnant necks after cerebral aneurysm clipping. MATERIALS AND METHODS: A total of 59 patients (77 aneurysms) underwent surgery using titanium clips. Two blinded observers independently evaluated the presence of neck remnants on shaded-surface display (SSD) imaging, volume rendered (VR) imaging, and intra-arterial digital subtraction angiography (IADSA). RESULTS: Mean sensitivity and specificity for detecting neck remnants were 50.0 and 74.2% for SSD imaging, 61.5 and 82.8% for VR imaging, and 92.3 and 92.2% for IADSA, respectively. Receiver operating characteristic (ROC) analysis revealed excellent diagnostic performance for IADSA [mean area under ROC curve (Az)=0.97], and good diagnostic performance for 3D-CTA (Az=0.70 and 0.76 for SSD and VR, respectively). Specificity of VR was better than that SSD (p=0.082), however, there was no significant difference between them. CONCLUSION: Use of 3D-CTA techniques can facilitate postoperative evaluation

  15. An Exploration of Gender Bias in Computer Clip Art.

    Science.gov (United States)

    Dyrud, Marilyn A.

    1997-01-01

    Examines over 14,000 clip art images for gender bias. Finds that only 4% of images depicted women and that those images present women in stereotypical roles, such as secretaries, nurses, teachers. Notes the irony that communication instructors expend much effort persuading students that gender-free prose is the new model--while visually still…

  16. 33 CFR 183.532 - Clips, straps, and hose clamps.

    Science.gov (United States)

    2010-07-01

    ... resistant material; and (2) Not cut or abrade the fuel line. (b) If tested in accordance with the fire test under § 183.590, a hose clamp installed on a fuel line system requiring metallic fuel lines or “USCG... (CONTINUED) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Equipment Standards § 183.532 Clips...

  17. A clip domain serine protease involved in moulting in the silkworm, Bombyx mori: cloning, characterization, expression patterns and functional analysis.

    Science.gov (United States)

    Liu, H-W; Wang, L-L; Meng, Z; Tang, X; Li, Y-S; Xia, Q-Y; Zhao, P

    2017-10-01

    Clip domain serine proteases (CLIPs), characterized by one or more conserved clip domains, are essential components of extracellular signalling cascades in various biological processes, especially in innate immunity and the embryonic development of insects. Additionally, CLIPs may have additional non-immune functions in insect development. In the present study, the clip domain serine protease gene Bombyx mori serine protease 95 (BmSP95), which encodes a 527-residue protein, was cloned from the integument of B. mori. Bioinformatics analysis indicated that BmSP95 is a typical CLIP of the subfamily D and possesses a clip domain at the N terminus, a trypsin-like serine protease (tryp_spc) domain at the C terminus and a conserved proline-rich motif between these two domains. At the transcriptional level, BmSP95 is expressed in the integument during moulting and metamorphosis, and the expression pattern is consistent with the fluctuating 20-hydroxyecdysone (20E) titre in B. mori. At the translational level, BmSP95 protein is synthesized in the epidermal cells, secreted as a zymogen and activated in the moulting fluid. Immunofluorescence revealed that BmSP95 is distributed into the old endocuticle in the moulting stage. The expression of BmSP95 was upregulated by 20E. Moreover, expression of BmSP95 was downregulated by pathogen infection. RNA interference-mediated silencing of BmSP95 led to delayed moulting from pupa to moth. These results suggest that BmSP95 is involved in integument remodelling during moulting and metamorphosis. © 2017 The Royal Entomological Society.

  18. Surgical Clipping versus Endovascular Intervention for the Treatment of Subarachnoid Hemorrhage Patients in New York State.

    Directory of Open Access Journals (Sweden)

    Kimon Bekelis

    Full Text Available Randomized trials have demonstrated a survival benefit for endovascular treatment of ruptured cerebral aneurysms. We investigated the association of surgical clipping and endovascular coiling with outcomes in subarachnoid hemorrhage (SAH patients in a real-world regional cohort.We performed a cohort study involving patients with ruptured cerebral aneurysms, who underwent surgical clipping, or endovascular coiling from 2009-2013 and were registered in the Statewide Planning and Research Cooperative System (SPARCS database. An instrumental variable analysis was used to investigate the association of treatment technique with outcomes.Of the 4,098 patients undergoing treatment, 2,585 (63.1% underwent coiling, and 1,513 (36.9% underwent clipping. Using an instrumental variable analysis, we did not identify a difference in inpatient mortality [marginal effect (ME, -0.56; 95% CI, -1.03 to 0.02], length of stay (LOS (ME, 1.72; 95% CI, -3.39 to 6.84, or the rate of 30-day readmissions (ME, -0.30; 95% CI, -0.82 to 0.22 between the two treatment techniques for patients with SAH. Clipping was associated with a higher rate of discharge to rehabilitation (ME, 0.63; 95% CI, 0.24 to 1.01. In sensitivity analysis, mixed effect regression, and propensity score adjusted regression models demonstrated identical results.Using a comprehensive all-payer cohort of patients in New York State presenting with aneurysmal SAH we did not identify an association of treatment method with mortality, LOS or 30-day readmission. Clipping was associated with a higher rate of discharge to rehabilitation.

  19. Cerebral Aneurysm Clipping Surgery Simulation Using Patient-Specific 3D Printing and Silicone Casting.

    Science.gov (United States)

    Ryan, Justin R; Almefty, Kaith K; Nakaji, Peter; Frakes, David H

    2016-04-01

    Neurosurgery simulator development is growing as practitioners recognize the need for improved instructional and rehearsal platforms to improve procedural skills and patient care. In addition, changes in practice patterns have decreased the volume of specific cases, such as aneurysm clippings, which reduces the opportunity for operating room experience. The authors developed a hands-on, dimensionally accurate model for aneurysm clipping using patient-derived anatomic data and three-dimensional (3D) printing. Design of the model focused on reproducibility as well as adaptability to new patient geometry. A modular, reproducible, and patient-derived medical simulacrum was developed for medical learners to practice aneurysmal clipping procedures. Various forms of 3D printing were used to develop a geometrically accurate cranium and vascular tree featuring 9 patient-derived aneurysms. 3D printing in conjunction with elastomeric casting was leveraged to achieve a patient-derived brain model with tactile properties not yet available from commercial 3D printing technology. An educational pilot study was performed to gauge simulation efficacy. Through the novel manufacturing process, a patient-derived simulacrum was developed for neurovascular surgical simulation. A follow-up qualitative study suggests potential to enhance current educational programs; assessments support the efficacy of the simulacrum. The proposed aneurysm clipping simulator has the potential to improve learning experiences in surgical environment. 3D printing and elastomeric casting can produce patient-derived models for a dynamic learning environment that add value to surgical training and preparation. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Epicardial clip occlusion of the left atrial appendage during cardiac surgery provides optimal surgical results and long-term stability.

    Science.gov (United States)

    Kurfirst, Vojtech; Mokrácek, Aleš; Canádyová, Júlia; Frána, Radim; Zeman, Petr

    2017-07-01

    Occlusion of the left atrial appendage (LAA) has become an integral and important part of the surgical treatment of atrial fibrillation. Different methods of surgical occlusion of the LAA have been associated with varying levels of short- and long-term success for closure. The purpose of this study was to evaluate long-term results of epicardial placement and endocardial occlusion in patients undergoing cardiac operative procedures. A total of 101 patients (average age 65.7 years) undergoing cardiac operative procedures with the epicardial AtriClip Exclusion System of the LAA were enrolled in the study. The AtriClip was placed via a sternotomy or a thoracotomy or from a thoracoscopic approach. Postoperative variables, such as thromboembolic events, clip stability and endocardial leakage around the device, were examined by transoesophageal echocardiography (TEE) and/or computed tomography. Perioperative clip implantation was achieved in 98% of patients. TEE and/or computed tomography conducted during the follow-up period, comprising 1873 patient-months with a mean duration of 18 ± 11 months, revealed no clip migration, no leakage around the device and no clot formation near the remnant cul-de-sac. During the follow-up period, 4 of the cardiac patients experienced transitory ischaemic attacks, whereas no patient experienced a cerebrovascular attack. The Epicardial AtriClip Exclusion System of the LAA appears to be a feasable and safe operative method with a high success rate. Long-term follow-up confirmed clip stability, complete occlussion of the LAA and absence of any atrial fibrilation-related thromboembolic events. These results need to be confirmed by a larger, multicentre study. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. Clipping treatment of posterior communicating artery aneurysms associated with arteriosclerosis and calcification: A single center study of 136 cases.

    Science.gov (United States)

    Shi, Lei; Yu, Jing; Zhao, Ying; Xu, Kan; Yu, Jinlu

    2018-02-01

    It is widely acknowledged that arteriosclerosis and calcification of the parent artery and aneurysm neck make it difficult to clip posterior communicating artery (PCoA) aneurysms. A total of 136 cases of PCoA aneurysms accompanied by arteriosclerosis and calcification were collected and treated with clipping in the present study. Of the 136 patients, 112 were females (82.4%) and 24 were males (17.6%), with ages ranging from 37 to 76 years (mean age, 60.2 years). Rupture of a PCoA aneurysm was identified in 132 cases (97.1%), and there were 4 cases of unruptured PCoA aneurysms (2.9%). According to the severity of arteriosclerosis and calcification, the aneurysms were divided into type I, II or III. The treatment of type I aneurysms achieved the best curative effect. It is difficult to temporarily occlude type II and III aneurysms during surgery, and temporary occlusion failed in almost 50% of cases. Types II and III were prone to intraoperative aneurysm ruptures. A significantly higher rate of intraoperative aneurysm rupture was seen in type III compared with type II cases. Type II and III cases were more likely to be treated using a fenestrated clip for aneurysm clipping compared with type I cases, and fenestrated clips were used significantly more frequently in type III cases compared with type II cases. Arteriosclerosis and calcification were likely to affect the prognosis of patients, particularly in cases with type III arteriosclerosis and calcification of the parent artery and aneurysm neck. Therefore, the stratification of the arteriosclerosis and calcification of the parent artery and aneurysm neck into types I-III can guide the intraoperative aneurysm clipping strategy, aid in choosing the correct clips, and inform predictions of the occurrence of rupture and hemorrhage, as well as the prognosis for aneurysms.

  2. 78 FR 78319 - Media Bureau Seeks Comment on Application of the IP Closed Captioning Rules to Video Clips

    Science.gov (United States)

    2013-12-26

    ... Video Programming: Implementation of the Twenty-First Century Communications and Video Accessibility Act..., pursuant to the Twenty-First Century Communications and Video Accessibility Act of 2010 (``CVAA''),\\2\\ the... clips, especially news clips.\\8\\ The Commission stated that if it finds that consumers who are deaf or...

  3. Effect of advanced chronic kidney disease in clinical and echocardiographic outcomes of patients treated with MitraClip system

    DEFF Research Database (Denmark)

    Estévez-Loureiro, Rodrigo; Settergren, Magnus; Pighi, Michele

    2015-01-01

    BACKGROUND: Data regarding the influence of different levels of renal dysfunction on clinical and echocardiographic results of MitraClip therapy are scarce. We aimed to evaluate the impact of baseline advance renal failure in the outcomes of a cohort of patients treated with MitraClip. METHODS AN...

  4. Do medical students watch video clips in eLearning and do these facilitate learning?

    Science.gov (United States)

    Romanov, Kalle; Nevgi, Anne

    2007-06-01

    There is controversial evidence of the impact of individual learning style on students' performance in computer-aided learning. We assessed the association between the use of multimedia materials, such as video clips, and collaborative communication tools with learning outcome among medical students. One hundred and twenty-one third-year medical students attended a course in medical informatics (0.7 credits) consisting of lectures, small group sessions and eLearning material. The eLearning material contained six learning modules with integrated video clips and collaborative learning tools in WebCT. Learning outcome was measured with a course exam. Approximately two-thirds of students (68.6%) viewed two or more videos. Female students were significantly more active video-watchers. No significant associations were found between video-watching and self-test scores or the time used in eLearning. Video-watchers were more active in WebCT; they loaded more pages and more actively participated in discussion forums. Video-watching was associated with a better course grade. Students who watched video clips were more active in using collaborative eLearning tools and achieved higher course grades.

  5. MR liver imaging and cholangiography in the presence of surgical metallic clips at 1.5 and 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Merkle, Elmar M.; Thomas, John; Paulson, Erik K. [Duke University Medical Center, Department of Radiology, Box 3808, Durham, NC (United States); Dale, Brian M. [Siemens Medical Solutions, Cary, NC (United States)

    2006-10-15

    To evaluate whether clips from prior cholecystectomy impair image quality during magnetic resonance cholangiography (MRC) at 3 Tesla (T) compared with 1.5 T, surgical clips were embedded in a gel phantom and positioned at predefined distances from a fluid-filled tube designed to simulate the bile duct. The maximum clip distance was noted where susceptibility artifacts obscured the fluid-filled tube at 1.5 T and 3 T. Susceptibility artifact size was calculated for each sequence within each magnet class. In vivo analysis included 42 patients postcholecystectomy who underwent MRC at either 1.5 T or 3 T. In vitro, mean area of susceptibility artifacts was 104 mm{sup 2} on 3-T and 75 mm{sup 2} on 1.5-T MR imaging (MRI). While surgical clips within a 2-mm range impaired visualization of the fluid-filled tube on 1.5-T MRI, this range increased to 4 mm on 3-T MRI. In vivo, MRC image quality was impaired by susceptibility artifacts in three of 21 cases at 3 T and in two of 21 cases at 1.5 T. Overall, biliary pseudo-obstructions due to susceptibility artifacts from cholecystectomy surgical clips were not substantially more common on 3-T MRC in clinical practice, and patients with a history of prior cholecystectomy should not be excluded from a 3-T MRC. (orig.)

  6. Robotic-assisted partial nephrectomy: surgical technique using a 3-arm approach and sliding-clip renorrhaphy

    Directory of Open Access Journals (Sweden)

    Jose M. Cabello

    2009-04-01

    Full Text Available INTRODUCTION: For the treatment of renal tumors, minimally invasive nephron-sparing surgery has become increasingly performed due to proven efficiency and excellent functional and oncological outcomes. The introduction of robotics into urologic laparoscopic surgery has allowed surgeons to perform challenging procedures in a reliable and reproducible manner. We present our surgical technique for robotic assisted partial nephrectomy (RPN using a 3-arm approach, including a sliding-clip renorrhaphy. MATERIAL AND METHODS: Our RPN technique is presented which describes the trocar positioning, hilar dissection, tumor identification using intraoperative ultrasound for margin determination, selective vascular clamping, tumor resection, and reconstruction using a sliding-clip technique. CONCLUSION: RPN using a sliding-clip renorrhaphy is a valid and reproducible surgical technique that reduces the challenge of the procedure by taking advantage of the enhanced visualization and control afforded by the robot. The renorrhaphy described is performed under complete control of the console surgeon, and has demonstrated a reduction in the warm ischemia times in our series.

  7. Improving NAVFAC's total quality management of construction drawings with CLIPS

    Science.gov (United States)

    Antelman, Albert

    1991-01-01

    A diagnostic expert system to improve the quality of Naval Facilities Engineering Command (NAVFAC) construction drawings and specification is described. C Language Integrated Production System (CLIPS) and computer aided design layering standards are used in an expert system to check and coordinate construction drawings and specifications to eliminate errors and omissions.

  8. A comparison of two endoscopic closures: over-the-scope clip (OTSC) versus KING closure (endoloop plus clips) in a randomized long-term experimental study

    Czech Academy of Sciences Publication Activity Database

    Doležel, R.; Ryska, O.; Kollár, M.; Juhásová, Jana; Kalvach, J.; Ryska, M.; Martínek, J.

    2016-01-01

    Roč. 30, č. 11 (2016), s. 4910-4916 ISSN 0930-2794 R&D Projects: GA MZd(CZ) NT13634; GA MŠk ED2.1.00/03.0124 Institutional support: RVO:67985904 Keywords : NOTES * endoscopic closure * KING closure * over-the-scope clip Subject RIV: FJ - Surgery incl. Transplants Impact factor: 3.747, year: 2016

  9. Post-clip placement MRI following second-look US-guided core biopsy for suspicious lesions identified on breast MRI.

    Science.gov (United States)

    Song, Sung Eun; Cho, Nariya; Han, Wonshik

    2017-12-01

    To evaluate whether the post-clip placement MRI following second-look ultrasound (US)-guided core biopsy is useful to confirm the adequate sampling of suspicious lesions identified on breast MRI. Between 2014 and 2016, 31 consecutive women with 34 suspicious lesions that had not been identified on previous mammography or US were detected using MRI. Among them, 26 women with 29 lesions (mean size 1.5 cm, range 0.5-5.8 cm) found by second-look US underwent US-guided biopsy, subsequent clip insertion and post-clip placement MRI. Five women with five lesions that were not found by second-look US underwent MRI-guided biopsy. The technical success rate and lesion characteristics were described. The technical success rate was 96.6% (28/29). One failure case was a benign, 1.1-cm non-mass enhancement. Of the 28 success cases, 23 (82.1%) were masses and 5 (17.9%) were non-mass enhancements; 17 (60.7%) were benign, 4 (14.3%) were high-risk and 7 (25.0%) were malignant lesions. The technical success rate was 100% (28/28) for masses and 83.3% (5/6) for non-mass enhancements. Post-clip placement MRI following US-guided biopsy is useful in confirming the adequate sampling of lesions identified on MRI. This method could be an alternative to MRI-guided biopsy for lesions visible on US. • Post-clip MRI is useful for confirming adequate sampling of US-guided biopsy. • Post-clip MRI following US-guided biopsy revealed a 96.6 % technical success rate. • One technical failure case was a benign, 1.1-cm non-mass enhancement. • The technical success rate of US-guided biopsy for non-mass enhancements was 83.3 %.

  10. Automated information retrieval using CLIPS

    Science.gov (United States)

    Raines, Rodney Doyle, III; Beug, James Lewis

    1991-01-01

    Expert systems have considerable potential to assist computer users in managing the large volume of information available to them. One possible use of an expert system is to model the information retrieval interests of a human user and then make recommendations to the user as to articles of interest. At Cal Poly, a prototype expert system written in the C Language Integrated Production System (CLIPS) serves as an Automated Information Retrieval System (AIRS). AIRS monitors a user's reading preferences, develops a profile of the user, and then evaluates items returned from the information base. When prompted by the user, AIRS returns a list of items of interest to the user. In order to minimize the impact on system resources, AIRS is designed to run in the background during periods of light system use.

  11. Appearance and impact of post-operative intracranial clips and coils on whole-brain CT angiography and perfusion

    International Nuclear Information System (INIS)

    Roach, Cayce J.; Russell, Cheryl L.; Hanson, Eric H.; Bluett, Brent; Orrison, William W.

    2012-01-01

    Background: To evaluate the effect of vascular clips and endovascular coils placed for intracranial aneurysms and arteriovenous malformations on whole-brain computed tomography (CT) angiography and perfusion. Methods: A 320-detector row dynamic volume CT system imaged 11 patients following surgical placement of vascular clips or endovascular coils. The extent of clip and coil subtraction by automated software was evaluated using CT digital subtraction angiography and CT perfusion. Impact on CT perfusion values by retained intracranial devices was compared to age- and gender-matched controls. Results: Clip and coil subtraction on CT angiography was graded as good in 8 and moderate in 3 cases. A residual neck and additional aneurysm were noted in 1 of 11 patients. Post-procedural axial slice level CT perfusion values decreased in reliability with increasing proximity to the metallic devices secondary to beam hardening. However, the intracranial devices did not affect axial slice level CTP values of cerebral blood volume, cerebral blood flow and mean transit time outside of the level of the device. Time to peak values was globally decreased outside of the immediate vascular intervention region. Conclusions: Advances in CT technology have provided clinically useful subtraction of intracranial clips and coils. While CT perfusion values were altered in device subtraction areas and within beam hardening artifact areas; they can provide valuable postoperative information on whole-brain hemodynamics. In selected cases, the combination of CT angiography and whole-brain CT perfusion can offer an alternative to conventional angiography that is a more invasive option.

  12. Real-time video streaming of sonographic clips using domestic internet networks and free videoconferencing software.

    Science.gov (United States)

    Liteplo, Andrew S; Noble, Vicki E; Attwood, Ben H C

    2011-11-01

    As the use of point-of-care sonography spreads, so too does the need for remote expert over-reading via telesonogrpahy. We sought to assess the feasibility of using familiar, widespread, and cost-effective existent technology to allow remote over-reading of sonograms in real time and to compare 4 different methods of transmission and communication for both the feasibility of transmission and image quality. Sonographic video clips were transmitted using 2 different connections (WiFi and 3G) and via 2 different videoconferencing modalities (iChat [Apple Inc, Cupertino, CA] and Skype [Skype Software Sàrl, Luxembourg]), for a total of 4 different permutations. The clips were received at a remote location and recorded and then scored by expert reviewers for image quality, resolution, and detail. Wireless transmission of sonographic clips was feasible in all cases when WiFi was used and when Skype was used over a 3G connection. Images transmitted via a WiFi connection were statistically superior to those transmitted via 3G in all parameters of quality (average P = .031), and those sent by iChat were superior to those sent by Skype but not statistically so (average P = .057). Wireless transmission of sonographic video clips using inexpensive hardware, free videoconferencing software, and domestic Internet networks is feasible with retention of image quality sufficient for interpretation. WiFi transmission results in greater image quality than transmission by a 3G network.

  13. Comparison of Outcome After Percutaneous Mitral Valve Repair With the MitraClip in Patients With Versus Without Atrial Fibrillation

    NARCIS (Netherlands)

    Velu, Juliëtte F.; Kortlandt, Friso A.; Hendriks, Tom; Schurer, Remco A. J.; van Boven, Ad J.; Koch, Karel T.; Vis, M. Marije; Henriques, Jose P.; Piek, Jan J.; van den Branden, Ben J. L.; Schaap, Jeroen; Rensing, Benno J.; Swaans, Martin J.; Bouma, Berto J.; van der Heyden, Jan A. S.; Baan, Jan

    2017-01-01

    Percutaneous mitral valve repair with the MitraClip is an established treatment for patients with mitral regurgitation (MR) who are inoperable or at high risk for surgery. Atrial Fibrillation (AF) frequently coincides with MR, but only scarce data of the influence of AF on outcome after MitraClip is

  14. Clipping Versus Coiling in the Management of Posterior Communicating Artery Aneurysms with Third Nerve Palsy: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Gaberel, Thomas; Borha, Alin; di Palma, Camille; Emery, Evelyne

    2016-03-01

    To compare surgical clipping with endovascular coiling in terms of recovery from oculomotor nerve palsy (ONP) in the management of posterior communicating artery (PCoA) aneurysms causing third nerve palsy. We conducted a systematic review of the literature and meta-analysis. The meta-analysis included 11 relevant studies involving 384 patients with third nerve palsy caused by PCoA aneurysms at baseline, of whom 257 (67.0%) were treated by clipping and 127 were treated by coiling (33.0%). Pooled odds ratios of the impact of clipping or coiling on complete ONP recovery, lack of ONP recovery, and procedure-related death were calculated. The overall complete ONP recovery rate was 42.5% in the coiling group compared with 83.6% in the clipping group. The increase in complete ONP recovery in the clipping group corresponds to an overall pooled Mantel-Haenszel odds ratio of 4.44 (95% confidence interval = 1.66-11.84). Subgroup analysis revealed a clear benefit of clipping over coiling in patients with ruptured aneurysms, but not in patients with unruptured aneurysms. No procedure-related deaths were reported by any of the 11 studies. Surgical clipping of PCoA aneurysms causing third nerve palsy achieves better ONP recovery than endovascular coiling; this could be particularly true in the case of ruptured aneurysms. In view of the purely observational data, statements about this effect should be made with great caution. A randomized trial would better address the therapeutic dilemma, but pending the results of such a trial, we recommend treating PCoA aneurysms causing ONP with surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Clinical features and nail clippings in 52 children with psoriasis.

    Science.gov (United States)

    Uber, Marjorie; Carvalho, Vânia O; Abagge, Kerstin T; Robl Imoto, Renata; Werner, Betina

    2018-03-01

    Nail clipping, the act of cutting the distal portion of a nail for microscopic analysis, can complement the diagnosis of skin diseases with nail involvement, such as psoriasis. This study aimed to describe histopathologic findings on 81 nails from 52 children and adolescents with skin psoriasis and to determine whether these changes correlated with the severity of skin and nail involvement. Children with psoriasis were enrolled in this cross-sectional study to obtain Psoriasis Area and Severity Index (PASI) and Nail Psoriasis Severity Index (NAPSI) scores. The most altered nails were processed using periodic acid-Schiff with diastase staining. Fifty-two patients with a median age of 10.5 years were included. The median Nail Psoriasis Severity Index score of the 20 nails from these patients was 17 (range 3-80). The most common findings were pitting (94.2%), leukonychia (73.0%), and longitudinal ridges (63.5%). Eighty-one nail fragments were collected by clipping. Neutrophils were found in 6 samples (7.6%) and serous lakes in 15 (19%). Median nail plate thickness was 0.3 mm (range 0.1-0.63 mm). Patients whose nails had neutrophils had a higher median PASI score (6.1 vs 2.0, P = .03). Patients whose nails had serous lakes had higher median PASI (5.3 vs 1.9, P = .008) and NAPSI (median 45.0 vs 18.0, P = .006) scores. There seems to be a correlation between some microscopic nail features in children with psoriasis and their PASI and NAPSI scores, so nail clippings from children with suspected psoriasis may help with diagnosis, especially in the presence of neutrophils, and in excluding onychomycosis. © 2018 Wiley Periodicals, Inc.

  16. Endoscopic Management of Gastrointestinal Leaks and Bleeding with the Over-the-Scope Clip: A Prospective Study

    Directory of Open Access Journals (Sweden)

    Mahesh Kumar Goenka

    2017-01-01

    Full Text Available Background/Aims The over-the-scope clip (OTSC is a device used for endoscopic closure of perforations, leaks and fistulas, and for endoscopic hemostasis. To evaluate the clinical effectiveness and safety of OTSC. Methods Between October 2013 and November 2015, 12 patients underwent OTSC placement by an experienced endoscopist. OTSC was used for the closure of gastrointestinal (GI leaks and fistula in six patients, three of which were iatrogenic (esophageal, gastric, and duodenal and three of which were inflammatory. In six patients, OTSC was used for hemostasis of non-variceal upper GI bleeding. Endoscopic tattooing using India ink was used to assist the accurate placement of the clip. Results All subjects except one with a colonic defect experienced immediate technical success as well as long-term clinical success, during a mean follow-up of 6 weeks. Only one clip was required to close each of the GI defects and to achieve hemostasis in all patients. There were no misfirings or complications of clips. The procedure was well tolerated, and patients were hospitalized for an average of 8 days (range, 3 to 10. Antiplatelet therapy was continued in patients with GI bleeding. Conclusions In our experience, OTSC was safe and effective for the closure of GI defect and to achieve hemostasis of non-variceal GI bleeding.

  17. Preoperative Prediction of the Necessity for Anterior Clinoidectomy During Microsurgical Clipping of Ruptured Posterior Communicating Artery Aneurysms.

    Science.gov (United States)

    Kamide, Tomoya; Burkhardt, Jan-Karl; Tabani, Halima; Safaee, Michael M; Lawton, Michael T

    2018-01-01

    Although most posterior communicating artery (PCoA) aneurysms can be clipped easily with excellent results, some require anterior clinoidectomy for safe and complete clipping. To review our microsurgical series of ruptured PCoA aneurysms and identify the preoperative predictors for anterior clinoidectomy during microsurgical clipping for PCoA aneurysms. Results from microsurgical clipping of 104 patients with ruptured PCoA aneurysms were reviewed retrospectively. Distances and angles were obtained from computed tomographic angiography and compared between the anterior and nonanterior clinoidectomy groups. Anterior clinoidectomy was required in 19 of the 104 cases (18%). None developed surgical complications due to anterior clinoid process (ACP) resection, including postoperative visual deficit. Univariate and multivariate analyses revealed that the distances from the ACP tip to the aneurysmal proximal neck and from the ACP line to the aneurysmal proximal neck were statistically significant predictive factors for the need of anterior clinoidectomy. Based on a receiver operating characteristic analysis, the distances from the ACP tip to the aneurysmal proximal neck PCoA aneurysm surgery, the distances from the ACP tip to the aneurysmal proximal neck and from the ACP line to the aneurysmal proximal neck were both found to be useful predictors of whether anterior clinoidectomy was required. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. A comparison of CLIPS- and LISP-based approaches to the development of a real-time expert system

    Science.gov (United States)

    Frainier, R.; Groleau, N.; Bhatnagar, R.; Lam, C.; Compton, M.; Colombano, S.; Lai, S.; Szolovits, P.; Manahan, M.; Statler, I.

    1990-01-01

    This paper describes an ongoing expert system development effort started in 1988 which is evaluating both CLIPS- and LISP- based approaches. The expert system is being developed to a project schedule and is planned for flight on Space Shuttle Mission SLS-2 in 1992. The expert system will help astronauts do the best possible science for a vestibular physiology experiment already scheduled for that mission. The system gathers and reduces data from the experiment, flags 'interesting' results, and proposes changes in the experiment both to exploit the in-flight observations and to stay within the time allowed by Mission Control for the experiment. These tasks must all be performed in real time. Two Apple Macintosh computers are used. The CLIPS- and LISP- based environments are layered above the Macintosh computer Operating System. The 'CLIPS-based' environment includes CLIPS and HyperCard. The LlSP-based environment includes Common LISP, Parmenides (a frame system), and FRuleKit (a rule system). Important evaluation factors include ease of programming, performance against real-time requirements, usability by an astronaut, robustness, and ease of maintenance. Current results on the factors of ease of programming, performance against real-time requirements, and ease of maintenance are discussed.

  19. Evaluation of Clipping Based Iterative PAPR Reduction Techniques for FBMC Systems

    Directory of Open Access Journals (Sweden)

    Zsolt Kollár

    2014-01-01

    to conventional orthogonal frequency division multiplexing (OFDM technique. The low ACLR of the transmitted FBMC signal makes it especially favorable in cognitive radio applications, where strict requirements are posed on out-of-band radiation. Large dynamic range resulting in high peak-to-average power ratio (PAPR is characteristic of all sorts of multicarrier signals. The advantageous spectral properties of the high-PAPR FBMC signal are significantly degraded if nonlinearities are present in the transceiver chain. Spectral regrowth may appear, causing harmful interference in the neighboring frequency bands. This paper presents novel clipping based PAPR reduction techniques, evaluated and compared by simulations and measurements, with an emphasis on spectral aspects. The paper gives an overall comparison of PAPR reduction techniques, focusing on the reduction of the dynamic range of FBMC signals without increasing out-of-band radiation. An overview is presented on transmitter oriented techniques employing baseband clipping, which can maintain the system performance with a desired bit error rate (BER.

  20. Dysfunction of the temporalis muscle after pterional craniotomy for intracranial aneurysms: comparative, prospective and randomized study of one flap versus two flaps dieresis Disfunção do músculo temporal após craniotomia pterional para tratamento de aneurismas intracranianos: estudo comparativo, prospectivo e aleatório da diérese em camada única versus camada dupla

    Directory of Open Access Journals (Sweden)

    FRANCISCO CARLOS DE ANDRADE JR.

    1998-06-01

    Full Text Available Patients with intracranial aneurysm(s of the carotid artery territory, treated with pterional craniotomy, were prospectively and randomly addressed to one layer flap (n=36 or myocutaneous (MC versus two layers' dieresis (n=32 or interfascial (IF. The study protocol included the patient's sex, age, area of craniotomy, time of flap dieresis and synthesis, time of bone dieresis and synthesis, the intracranial time, including dura mater dieresis and synthesis and time of flap retraction. Before and after surgery, the patients were evaluated with examination specially oriented to V and VII cranial nerves, bi-temporal diameter measurement, the symmetry of the temporal region, tempora-mandibularis joint (TMJ movements and cranial CT scan. The evaluations of the TMJ dysfunctions were postoperative pain, movement limitations at mastication, occlusion, mouth aperture and lateral movements of the jaw. The statistical analysis showed that the incidence of pain at TMJ and moderate and severe temporalis muscle atrophy was observed, comparing MC and IF, and there were significant differences among these ones, being greater in IF group. We concluded that both techniques permit equivalent access to the studied intracranial aneurysm(s, and the atrophy of temporalis muscle, pain and movement limitations of the temporomandibularis joint were prevalent, worse and more long-lasting in two-layers flap dieresis than in one-layer flap dieresis.Pacientes com aneurisma(s intracraniano(s foram tratados pela via pterional e de modo prospectivo e aleatório submetidos às variantes técnicas, miocutânea (MC(n=36 ou em retalho único e interfascial (IF (n=32 ou em retalho duplo. No protocolo foram anotados o sexo, idade, área da craniotomia, período de diérese e síntese do retalho, período de diérese e síntese óssea, o período do procedimento intracraniano, incluindo o tempo de diérese e síntese da dura-máter e o período de retração do retalho. Os pacientes

  1. SYNTHESIS OF 25-HYDROXYVITAMIN D3 CONJUGATE WITH KEYHOLE LIMPET HEMOCYANIN AND OBTAINING OF IMMUNE SERA

    Directory of Open Access Journals (Sweden)

    А. O. Mazanova

    2015-08-01

    Full Text Available The study was aimed at obtaining polyclonal antibodies that recognize 25-Hydroxyvitamin D3, for their further specifications and applications in immunochemical test systems of 25-Hydroxyvitamin D3, determination in blood serum. We used the methods of chemical synthesis of immunoconjugates (modified carbodiimide method using N´-ethyl carbodiimide, thin layer chromatography, gel filtration and indirect immunoenzyme analysis ELISA. The work describes the stages of the synthesis of 25-Hydroxyvitamin D3, immunoconjugate with keyhole limpet hemocyanin (KLH, which was used for receiving immune sera. As a result of mouse and rabbit immunization antisera were obtained and antibody titers against 25-Hydroxyvitamin D3, were tested by immunoenzyme assay. It was demonstrated that the titer of specific antibodies was higher in rabbits compared with mice. The resulting polyclonal antibodies can be used for the development of immunochemical test systems for screening studies of 25-Hydroxyvitamin D3, content in human blood serum as a marker of vitamin D3 availability.

  2. Integrating knowledge and control into hypermedia-based training environments: Experiments with HyperCLIPS

    Science.gov (United States)

    Hill, Randall W., Jr.

    1990-01-01

    The issues of knowledge representation and control in hypermedia-based training environments are discussed. The main objective is to integrate the flexible presentation capability of hypermedia with a knowledge-based approach to lesson discourse management. The instructional goals and their associated concepts are represented in a knowledge representation structure called a 'concept network'. Its functional usages are many: it is used to control the navigation through a presentation space, generate tests for student evaluation, and model the student. This architecture was implemented in HyperCLIPS, a hybrid system that creates a bridge between HyperCard, a popular hypertext-like system used for building user interfaces to data bases and other applications, and CLIPS, a highly portable government-owned expert system shell.

  3. Accurate multi-robot targeting for keyhole neurosurgery based on external sensor monitoring.

    Science.gov (United States)

    Comparetti, Mirko Daniele; Vaccarella, Alberto; Dyagilev, Ilya; Shoham, Moshe; Ferrigno, Giancarlo; De Momi, Elena

    2012-05-01

    Robotics has recently been introduced in surgery to improve intervention accuracy, to reduce invasiveness and to allow new surgical procedures. In this framework, the ROBOCAST system is an optically surveyed multi-robot chain aimed at enhancing the accuracy of surgical probe insertion during keyhole neurosurgery procedures. The system encompasses three robots, connected as a multiple kinematic chain (serial and parallel), totalling 13 degrees of freedom, and it is used to automatically align the probe onto a desired planned trajectory. The probe is then inserted in the brain, towards the planned target, by means of a haptic interface. This paper presents a new iterative targeting approach to be used in surgical robotic navigation, where the multi-robot chain is used to align the surgical probe to the planned pose, and an external sensor is used to decrease the alignment errors. The iterative targeting was tested in an operating room environment using a skull phantom, and the targets were selected on magnetic resonance images. The proposed targeting procedure allows about 0.3 mm to be obtained as the residual median Euclidean distance between the planned and the desired targets, thus satisfying the surgical accuracy requirements (1 mm), due to the resolution of the diffused medical images. The performances proved to be independent of the robot optical sensor calibration accuracy.

  4. Impact of metal artifact reduction software on image quality of gemstone spectral imaging dual-energy cerebral CT angiography after intracranial aneurysm clipping

    Energy Technology Data Exchange (ETDEWEB)

    Dunet, Vincent; Bernasconi, Martine; Hajdu, Steven David; Meuli, Reto Antoine; Zerlauth, Jean-Baptiste [Lausanne University Hospital, Department of Diagnostic and Interventional Radiology, Lausanne (Switzerland); Daniel, Roy Thomas [Lausanne University Hospital, Department of Neurosurgery, Lausanne (Switzerland)

    2017-09-15

    We aimed to assess the impact of metal artifact reduction software (MARs) on image quality of gemstone spectral imaging (GSI) dual-energy (DE) cerebral CT angiography (CTA) after intracranial aneurysm clipping. This retrospective study was approved by the institutional review board, which waived patient written consent. From January 2013 to September 2016, single source DE cerebral CTA were performed in 45 patients (mean age: 60 ± 9 years, male 9) after intracranial aneurysm clipping and reconstructed with and without MARs. Signal-to-noise (SNR), contrast-to-noise (CNR), and relative CNR (rCNR) ratios were calculated from attenuation values measured in the internal carotid artery (ICA) and middle cerebral artery (MCA). Volume of clip and artifacts and relative clip blurring reduction (rCBR) ratios were also measured at each energy level with/without MARs. Variables were compared between GSI and GSI-MARs using the paired Wilcoxon signed-rank test. MARs significantly reduced metal artifacts at all energy levels but 130 and 140 keV, regardless of clips' location and number. The optimal rCBR was obtained at 110 and 80 keV, respectively, on GSI and GSI-MARs images, with up to 96% rCNR increase on GSI-MARs images. The best compromise between metal artifact reduction and rCNR was obtained at 70-75 and 65-70 keV for GSI and GSI-MARs images, respectively, with up to 15% rCBR and rCNR increase on GSI-MARs images. MARs significantly reduces metal artifacts on DE cerebral CTA after intracranial aneurysm clipping regardless of clips' location and number. It may be used to reduce radiation dose while increasing CNR. (orig.)

  5. Comparisons of spectrally-enhanced asymmetrically-clipped optical OFDM systems.

    Science.gov (United States)

    Lowery, Arthur James

    2016-02-22

    Asymmetrically clipped optical orthogonal frequency-division multiplexing (ACO-OFDM) is a technique that sacrifices spectral efficiency in order to transmit an orthogonally frequency-division multiplexed signal over a unipolar channel, such as a directly modulated direct-detection fiber or free-space channel. Several methods have been proposed to regain this spectral efficiency, including: asymmetrically clipped DC-biased optical OFDM (ADO-OFDM), enhanced U-OFDM (EU-OFDM), spectral and energy efficient OFDM (SEE-OFDM), Hybrid-ACO-OFDM and Layered-ACO-OFDM. This paper presents simulations up to high-order constellation sizes to show that Layered-ACO-OFDM offers the highest receiver sensitivity for a given optical power at spectral efficiencies above 3 bit/s/Hz. For comparison purposes, white Gaussian noise is added at the receiver, component nonlinearities are not considered, and the fiber is considered to be linear and dispersion-less. The simulations show that LACO-OFDM has a 7-dB sensitivity advantage over DC-biased OFDM (DCO-OFDM) for 1024-QAM at 87.5% of DCO-OFDM's spectral efficiency, at the same bit rate and optical power. This is approximately equivalent to a 4.4-dB advantage at the same spectral efficiency of 87.7% if 896-QAM were to be used for DCO-OFDM.

  6. Drosophila Imp iCLIP identifies an RNA assemblage coordinating F-actin formation

    DEFF Research Database (Denmark)

    Hansen, Heidi Theil; Rasmussen, Simon Horskjær; Adolph, Sidsel Kramshøj

    2015-01-01

    BACKGROUND: Post-transcriptional RNA regulons ensure co-ordinated expression of monocistronic mRNAs encoding functionally related proteins. In this study, we employ a combination of RIP-seq and short- and long-wave individual-nucleotide resolution crosslinking and immunoprecipitation (iCLIP...

  7. Antarctic news clips - 1992

    Science.gov (United States)

    1992-07-01

    The newspaper and magazine stories selected for this book present only a sampling of one year's (July 1991 to July 1992) news coverage of Antarctica. The only requirement for inclusion in this publication is that the article's subject matter pertains or refers to Antarctica in some way - whether it is focused on the science done there, or on the people who play such a large part in the work accomplished, or on the issues related to it. No attempt has been made to correlate the number of articles, or their length, with the importance of the subjects treated. Clippings are provided to the Foundation by a service that searches for items containing the phrase 'National Science Foundation'. Identical versions of many stories, especially those written and distributed by wire services such as the Associated Press and United Press International, and by syndicated columnists, are published in numerous papers across the United States. Other articles are submitted from a variety of sources, including interested readers across the United States and in New Zealand.

  8. Effect of mental challenge induced by movie clips on action potential duration in normal human subjects independent of heart rate.

    Science.gov (United States)

    Child, Nicholas; Hanson, Ben; Bishop, Martin; Rinaldi, Christopher A; Bostock, Julian; Western, David; Cooklin, Michael; O'Neil, Mark; Wright, Matthew; Razavi, Reza; Gill, Jaswinder; Taggart, Peter

    2014-06-01

    Mental stress and emotion have long been associated with ventricular arrhythmias and sudden death in animal models and humans. The effect of mental challenge on ventricular action potential duration (APD) in conscious healthy humans has not been reported. Activation recovery intervals measured from unipolar electrograms as a surrogate for APD (n=19) were recorded from right and left ventricular endocardium during steady-state pacing, whilst subjects watched an emotionally charged film clip. To assess the possible modulating role of altered respiration on APD, the subjects then repeated the same breathing pattern they had during the stress, but without the movie clip. Hemodynamic parameters (mean, systolic, and diastolic blood pressure, and rate of pressure increase) and respiration rate increased during the stressful part of the film clip (P=0.001). APD decreased during the stressful parts of the film clip, for example, for global right ventricular activation recovery interval at end of film clip 193.8 ms (SD, 14) versus 198.0 ms (SD, 13) during the matched breathing control (end film left ventricle 199.8 ms [SD, 16] versus control 201.6 ms [SD, 15]; P=0.004). Respiration rate increased during the stressful part of the film clip (by 2 breaths per minute) and was well matched in the respective control period without any hemodynamic or activation recovery interval changes. Our results document for the first time direct recordings of the effect of a mental challenge protocol on ventricular APD in conscious humans. The effect of mental challenge on APD was not secondary to emotionally induced altered respiration or heart rate. © 2014 American Heart Association, Inc.

  9. Retrieval of Surgical Clip from Common Bile Duct by Endoscopic Retrograde Cholangiopancreatography: A Rare Complication of Laparoscopic Cholecystectomy

    Directory of Open Access Journals (Sweden)

    Shahid Rasool

    2017-04-01

    Full Text Available Laparoscopic cholecystectomy has become the standard procedure for the surgical management of symptomatic cholelithiasis. Laparoscopic cholecystectomy is generally considered a safe procedure although a few complications such as major bleeding, wound infection, bile leakage, biliary and bowel injury are well known. We are reporting a case of a thirty-seven year old male who presented with abdominal pain, three weeks after laparoscopic cholecystectomy. Abdominal ultrasound revealed a filling defect in common bile duct with deranged liver function tests. With an impression of choledocholithiasis, his endoscopic retrograde cholangiopancreatography (ERCP was done which revealed a surgical clip impacted in the ampulla. The surgical clip was retrieved successfully by ERCP. Intraductal clip migration is a rarely encountered complication after laparoscopic cholecystectomy. Appropriate management requires timely identification and retrieval during ERCP.

  10. Endoscopic Management of Gastrocutaneous Fistula Using Clipping, Suturing, and Plugging Methods

    Directory of Open Access Journals (Sweden)

    Shou-jiang Tang

    2014-09-01

    Conclusions: Health care providers need to be aware of this uncommon complication after PEG tube removal and management it with appropriate minimally invasive options where expertise and devices are available. Currently, tissue approximation with clips, intra-gastric and/or trans-abdominal suture placement is the preferred endoscopic options for fistula closure.

  11. Analyzing Behaviour of the Utilization of the Online News Clipping Database: Experience in Suan Sunandha Rajabhat University

    OpenAIRE

    Siriporn Poolsuwan; Kanyarat Bussaban

    2014-01-01

    This research aims to investigate and analyze user’s behaviour towards the utilization of the online news clipping database at Suan Sunandha Rajabhat University, Thailand. Data is gathered from 214 lecturers and 380 undergraduate students by using questionnaires. Findings show that most users knew the online news clipping service from their friends, library’s website and their teachers. The users learned how to use it by themselves and others learned by training of SSRU library. Most users us...

  12. Molecular Recognition Involving Anthraquinone Derivatives and Molecular Clips

    Science.gov (United States)

    Alaparthi, Madhubabu

    In the past, we have demonstrated that 1,8-anthraquinone-18-crown-5 (1) and its heterocyclic derivatives act as luminescent hosts for a variety of cations of environmental and clinical concern. We report here a series of heteroatom-substituted macrocycles containing an anthraquinone moiety as a fluorescent signaling unit and a cyclic polyheteroether chain as the receptor. Sulfur, selenium, and tellurium derivatives of 1,8-anthraquinone-18-crown-5 (1) were synthesized by reacting sodium sulfide (Na2S), sodium selenide (Na2Se) and sodium telluride (Na2Te) with 1,8-bis(2-bromoethylethyleneoxy)anthracene - 9,10-dione in a 1:1 ratio (2,3, and 6). These sensors bind metal ions in a 1:1 ratio (7 and 8), and the optical properties of the new complexes were examined and the sulfur and selenium analogues show that selectivity for Pb(II) is markedly improved as compared to the oxygen analogue 1 which was competitive for Ca(II) ion. Selective reduction of 1 yields secondary alcohols where either one or both of the anthraquinone carbonyl groups has been reduced ( 15 and 9). A new mechanism for the fluorescence detection of metal cations in solution is introduced involving a unique keto-enol tautomerization. Reduction of 1 yields the doubly reduced secondary alcohol, 9. 9 acts as a chemodosimeter for Al(III) ion producing a strong blue emission due to the formation of the anthracene fluorophore, 10, via dehydration of the internal secondary alcohol in DMSO/aqueous solution. The enol form is not the most thermodynamically stable form under these conditions however, and slowly converts to the keto form 11.. Currently we are focusing on cucurbituril derivatives, also described as molecular clips due to their folded geometry used as molecular recognition hosts. We first investigated the synthesis and characterization of aromatic methoxy/catechol terminated cucurbituril units that act as hosts for small solvent molecules, such as CH2Cl2, CH3CN, DMF, and MeOH, through dual pi...H-C T

  13. Fundamental Frequency Extraction Method using Central Clipping and its Importance for the Classification of Emotional State

    Directory of Open Access Journals (Sweden)

    Pavol Partila

    2012-01-01

    Full Text Available The paper deals with a classification of emotional state. We implemented a method for extracting the fundamental speech signal frequency by means of a central clipping and examined a correlation between emotional state and fundamental speech frequency. For this purpose, we applied an approach of exploratory data analysis. The ANOVA (Analysis of variance test confirmed that a modification in the speaker's emotional state changes the fundamental frequency of human vocal tract. The main contribution of the paper lies in investigation, of central clipping method by the ANOVA.

  14. The use of shape memory compression anastomosis clips in cholecystojejunostomy in pigs – a preliminary study

    Directory of Open Access Journals (Sweden)

    Piotr Holak

    2015-01-01

    Full Text Available This paper reports on the use of compression anastomosis clips (CAC in cholecystoenterostomy in an animal model. Cholecystojejunostomy was performed in 6 pigs using implants made of nickel-titanium alloy in the form of elliptical springs with two-way shape memory. The applied procedure led to the achievement of tight anastomosis with a minimal number of complications and positive results of histopathological evaluations of the anastomotic site. The results of the study indicate that shape memory NiTi clips are a promising surgical tool for cholecystoenterostomy in cats and dogs.

  15. Image quality and artefact generation post-cerebral aneurysm clipping using a 64-row multislice computer tomography angiography (MSCTA) technology: A retrospective study and review of the literature.

    Science.gov (United States)

    Zachenhofer, Iris; Cejna, Manfred; Schuster, Antonius; Donat, Markus; Roessler, Karl

    2010-06-01

    Computed tomography angiography (CTA) is a time and cost saving investigation for postoperative evaluation of clipped cerebral aneurysm patients. A retrospective study was conducted to analyse image quality and artefact generation due to implanted aneurysm clips using a new technology. MSCTA was performed pre- and postoperatively using a Philips Brilliance 64-detector-row CT scanner. Altogether, 32 clipping sites were analysed in 27 patients (11 female and 16 male, mean ages 52a, from 24 to 72 years). Clip number per aneurysm was 2.3 mean (from 1 to 4), 54 clips were made of titanium alloy and 5 of cobalt alloy. Altogether, image quality was rated 1.8 mean, using a scale from 1 (very good) to 5 (unserviceable) and clip artefacts were rated 2.4 mean, using a 5 point rating scale (1 no artefacts, 5 unserviceable due to artefacts). A significant loss of image quality and rise of artefacts was found when using cobalt alloy clips (1.4 versus 4.2 and 2.1 versus 4.0). In 72% of all investigations, an excellent image quality was found. Excluding the cobalt clip group, 85% of scans showed excellent image quality. Artefacts were absent or minimal (grade 1 or 2) in 69% of all investigations and in 81% in the pure titanium clip group. In 64-row MSCTA of good image quality with low artefacts, it was possible to detect small aneurysm remnants of 2mm size in individual patients. By using titanium alloy clips, in our study up to 85% of postoperative CTA images were of excellent quality with absent or minimal artefacts in 81% and seem adequate to detect small aneurysm remnants. Copyright 2010 Elsevier B.V. All rights reserved.

  16. Laparoscopic Filshie clip sterilization and selective use of the methylene blue dye test.

    Science.gov (United States)

    Karoshi, Mahantesh; Yoong, Wai

    2004-01-01

    In laparoscopic Filshie clip sterilization, difficulties may arise in identifying the length of the fallopian tube, with the possibility of failure of sterilization. This article describes a novel intraoperative method of demonstrating adequate tubal closure.

  17. Tailfin clipping, a painful procedure: Studies on Nile tilapia and common carp

    NARCIS (Netherlands)

    Roques, J.A.C.; Abbink, W.; Geurds, F.; Vis, van de J.W.; Flik, G.

    2010-01-01

    The fish welfare debate is intensifying. Consequently, more research is carried out to further our knowledge on fish welfare in aquaculture. We define here a series of key parameters to substantiate an acute response to a supposedly painful stimulus: a standardized tailfin clip. Ultrastructural

  18. Changes in salivary testosterone concentrations and subsequent voluntary squat performance following the presentation of short video clips.

    Science.gov (United States)

    Cook, Christian J; Crewther, Blair T

    2012-01-01

    Previous studies have shown that visual images can produce rapid changes in testosterone concentrations. We explored the acute effects of video clips on salivary testosterone and cortisol concentrations and subsequent voluntary squat performance in highly trained male athletes (n=12). Saliva samples were collected on 6 occasions immediately before and 15 min after watching a brief video clip (approximately 4 min in duration) on a computer screen. The watching of a sad, erotic, aggressive, training motivational, humorous or a neutral control clip was randomised. Subjects then performed a squat workout aimed at producing a 3 repetition maximum (3RM) lift. Significant (Psquats across all video sessions (Pfree hormone concentrations and the relative changes in testosterone closely mapped 3RM squat performance in a group of highly trained males. Thus, speculatively, using short video presentations in the pre-workout environment offers an opportunity for understanding the outcomes of hormonal change, athlete behaviour and subsequent voluntary performance. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. Haliotis tuberculata hemocyanin (HtH): analysis of oligomeric stability of HtH1 and HtH2, and comparison with keyhole limpet hemocyanin KLH1 and KLH2.

    Science.gov (United States)

    Harris, J R; Scheffler, D; Gebauer, W; Lehnert, R; Markl, J

    2000-12-01

    The multimeric/higher oligomeric states of the two isoforms of Haliotis tuberculata hemocyanin (HtH1 and HtH2) have been assessed by transmission electron microscopy (TEM) of negatively stained specimens, for comparison with previously published structural data from keyhole limpet hemocyanin (KLH1 and KLH2) [see Harris, J.R., Gebauer, W., Guderian, F.U., Markl, J., 1997a. Keyhole limpet hemocyanin (KLH), I: Reassociation from Immucothel followed by separation of KLH1 and KLH2. Micron, 28, 31-41; Harris, J.R., Gebauer, W., Söhngen, S.M., Nermut, M.V., Markl, J., 1997b. Keyhole limpet hemocyanin (KLH). II: Characteristic reassociation properties of purified KLH1 and KLH2. Micron, 28, 43-56; Harris, J.R., Gebauer, W., Adrian, M., Markl, J., 1998. Keyhole limpet hemocyanin (KLH): Slow in vitro reassociation of KLH1 and KLH2 from Immucothel. Micron, 29, 329-339]. In purified samples of both HtH isoforms, the hollow cylindrical ca 8MDa didecamer predominates together with a small number of decamers, but tri- and longer multidecamers are detectable only in the HtH2. The stability of the two HtH isoforms under varying ionic conditions have been monitored, thereby enabling conditions for the production of stable decamers to be established. The ability of these decamers to reform multimers in the presence of 10 and 100mM concentrations of calcium and magnesium ions in Tris-HCl buffer (pH 7.4), and also of individual HtH1 and HtH2 subunits (produced by pH 9.6 dissociation in glycine-NaOH buffer), to reassociate in the presence of calcium and magnesium ions, has been assessed. For the HtH1 decamers, the predominant multimeric product is the didecamer at 10 and 100mM calcium and magnesium concentrations, whereas for the HtH2 decamers, large numbers of multidecamers are produced, with the reaction proceeding more completely at the higher calcium and magnesium concentration. With the HtH1 subunit, reassociation in the presence of 10 and 100mM calcium and magnesium ions yielded

  20. Analysis of Surgical Freedom Variation Across the Basilar Artery Bifurcation: Towards a Deeper Insight Into Approach Selection for Basilar Apex Aneurysms.

    Science.gov (United States)

    Tayebi Meybodi, Ali; Benet, Arnau; Rodriguez Rubio, Roberto; Yousef, Sonia; Lawton, Michael T

    2018-03-03

    The orbitozygomatic approach is generally advocated over the pterional approach for basilar apex aneurysms. However, the impact of the extensions of the pterional approach on the obtained maneuverability over multiple vascular targets (relevant to basilar apex surgery) has not been studied before. To analyze the patterns of surgical freedom change across the basilar bifurcation between the pterional, orbitopterional, and orbitozygomatic approaches. Surgical freedom was assessed for 3 vascular targets important in basilar apex aneurysm surgery (ipsilateral and contralateral P1-P2 junctions, and basilar apex), and compared between the pterional, orbitopterional, and orbitozygomatic approaches in 10 cadaveric specimens. Transitioning from the pterional to orbitopterional approach, the surgical freedom increased significantly at all 3 targets (P < .05). However, the gain in surgical freedom declined progressively from the most superficial target (60% for ipsilateral P1-P2 junction) to the deepest target (35% for contralateral P1-P2 junction). Conversely, transitioning from the orbitopterional to the orbitozygomatic approach, the gain in surgical freedom was minimal for the ipsilateral P1-P2 and basilar apex (<4%), but increased dramatically to 19% at the contralateral P1-P2 junction. The orbitopterional approach provides a remarkable increase in surgical maneuverability compared to the pterional approach for the basilar apex target and the relevant adjacent arterial targets. However, compared to the orbitopterional, the orbitozygomatic approach adds little maneuverability except for the deepest target (ie, contralateral P1-P2 junction). Therefore, the orbitozygomatic approach may be most efficacious with larger basilar apex aneurysms limiting the control over of the contralateral P1 PCA.

  1. Laparoscopic cholecystectomy without clips: 50 cases

    International Nuclear Information System (INIS)

    Morales Gonzalez, Raul A.; Goderich Lalan, Jose M.; Gonzalez Constanten, Juan

    2001-01-01

    A prospective and descriptive study that included 50 patients operated on of vesicular lithiasis by minimally invasive surgery and in whom the clips Were substituted by intra corporeal knots was conducted aimed at knowing the results of this procedure. These patients received attention at Celia Sanchez Manduley, Provincial Clinical and Surgical Teaching Hospital from April 12 to May 3, 2000. Aspects such as age, sex, surgical time, complications and hospital costs Were analyzed. The surgical time was 20 min higher than the one used in a by the usual technique. There Were no surgical complications. It was possible to reduce the cost of surgery. It is considered that this variable is safe, more economic and may be performed in a time similar to the one used in the usual technique

  2. Three-port laparoscopic cholecystectomy by harmonic dissection without cystic duct and artery clipping.

    Science.gov (United States)

    Tebala, Giovanni D

    2006-05-01

    The technique of laparoscopic cholecystectomy (LC) still has areas of refinements. To decrease the number of ports, a cannula may be replaced by a percutaneous suture suspension of the gallbladder. The risk of tissue injury caused by repeat blind extraction and insertion of various instruments in and out of the abdomen may be decreased by the use of the multipurpose harmonic dissector. One hundred consecutive patients with symptomatic cholelithiasis underwent 3-port LC entirely performed by harmonic dissector without cystic duct and artery clipping. In 8 cases, a fourth trocar was necessary. In 2 cases, the cystic duct was clipped after an unsafe ultrasound sealing. In 1 case, continuous bleeding from the liver required the use of diathermy. No common bile duct injury was registered. The 3-port harmonic LC is a feasible, effective, and safe technique.

  3. Use of activation analysis method for determining trace elements in human nail clippings

    International Nuclear Information System (INIS)

    Aguiar, Amilton Reinaldo; Saiki, Mitiko

    1999-01-01

    This work presents results obtained in nail clipping samples analyses. These nail samples were collected from healthy group of individuals and from patients with cystic fibrosis disease. Irradiation of nail clippings was carried out with a thermal neutron flux from 10 11 to 10 13 n.cm -2 .s -1 at the IEA-R1m nuclear research reactor and the elements Al, As, Br, Ca, cd, Cl, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Se and Zn were determined. The results obtained for healthy group were within the range of concentrations published, for normal population. However for several elements, the group of patients presented higher concentrations than those presented for healthy individuals. The precision and the accuracy of the results were evaluated by analyzing reference materials NIST 1577b Bovine Liver and 1566a Oyster Tissue. (author)

  4. Advanced technical skills are required for microsurgical clipping of posterior communicating artery aneurysms in the endovascular era.

    Science.gov (United States)

    Sanai, Nader; Caldwell, Nolan; Englot, Dario J; Lawton, Michael T

    2012-08-01

    Many neurosurgeons feel competent clipping posterior communicating artery (PCoA) aneurysms and include this lesion in their practice. However, endovascular therapy removes simple aneurysms that would have been easiest to clip with the best results. What remains are aneurysms with complex anatomy and technical challenges that are not well described. A contemporary surgical series with PCoA aneurysms is reviewed to define the patients, microsurgical techniques, and outcomes in current practice. A total of 218 patients had 218 PCoA aneurysms that were treated microsurgically during an 11-year period. Complexities influencing aneurysm management included (1) large/giant size; (2) fetal posterior cerebral artery; (3) previous coiling; (4) anterior clinoidectomy; (5) adherence of the anterior choroidal artery (AChA); (6) intraoperative aneurysm rupture; (7) complex clipping; and (8) atherosclerotic calcification. Simple PCoA aneurysms were encountered in 113 patients (51.8%) and complex aneurysms in 105 (48.2%). Adherent AChA (13.8%) and intraoperative rupture (11.5%) were the most common complexities. Simple aneurysms had favorable outcomes in 86.6% of patients, whereas aneurysms with 1 or multiple complexities had favorable outcomes in 78.2% and 75.0%, respectively. Intraoperative rupture (P PCoA aneurysms requires advanced techniques including clinoidectomy, AChA microdissection, complex clipping, and facility with intraoperative rupture. Microsurgery is recommended for recurrent aneurysms after coiling, complex branches, aneurysms causing oculomotor nerve palsy, multiple aneurysms, and patients with hematomas.

  5. Removal time and efficacy of Riddell Quick Release Face Guard Attachment System side clips during 1 football season.

    Science.gov (United States)

    Gruppen, Tonia; Smith, Molly; Ganss, Andrea

    2012-01-01

    In the National Athletic Trainers' Association position statement, "Acute Management of the Cervical Spine-Injured Athlete," the technique recommended for face-mask (FM) removal is one that "creates the least head and neck motion, is performed most quickly, is the least difficult, and carries the least chance of failure." Industrial and technological advances in football helmet design and FM attachment systems might influence the efficacy of emergency FM removal. To examine the removal times and success rates of the Quick Release (QR) Face Guard Attachment System (Riddell Sports, Inc, Elyria, OH) throughout and at the conclusion of 1 season of play by a National Collegiate Athletic Association Division III football team competing in the Midwest. Controlled laboratory study. College laboratory. A total of 69 randomly selected Revolution IQ (Riddell Sports, Inc) football helmets fitted with the QR system were used. Each helmet was secured to a spine board, and investigators attempted to remove both of the QR side clips from the helmet with the Riddell insertion tool. Dependent variables included total time for removal of both QR side clips from the FM and success rate for removal of both side clips. The overall success rate for removal of both clips was 94.8% (164/173), whereas the mean times for removal of both clips ranged from 9.92 ± 12.06 seconds to 16.65 ± 20.97 seconds over 4 trial sessions. We found no differences among mean times for trial sessions throughout the season of play among the same helmets or among different helmets (P > .05). Removal time and success rate of the Riddell QR were satisfactory during and after 1 season of play despite use in various temperatures and precipitation.

  6. Removal Time and Efficacy of Riddell Quick Release Face Guard Attachment System Side Clips During 1 Football Season

    Science.gov (United States)

    Gruppen, Tonia; Smith, Molly; Ganss, Andrea

    2012-01-01

    Context In the National Athletic Trainers' Association position statement, “Acute Management of the Cervical Spine-Injured Athlete,” the technique recommended for face-mask (FM) removal is one that “creates the least head and neck motion, is performed most quickly, is the least difficult, and carries the least chance of failure.” Industrial and technological advances in football helmet design and FM attachment systems might influence the efficacy of emergency FM removal. Objective To examine the removal times and success rates of the Quick Release (QR) Face Guard Attachment System (Riddell Sports, Inc, Elyria, OH) throughout and at the conclusion of 1 season of play by a National Collegiate Athletic Association Division III football team competing in the Midwest. Design Controlled laboratory study. Setting College laboratory. Patients or Other Participants A total of 69 randomly selected Revolution IQ (Riddell Sports, Inc) football helmets fitted with the QR system were used. Intervention(s) Each helmet was secured to a spine board, and investigators attempted to remove both of the QR side clips from the helmet with the Riddell insertion tool. Main Outcome Measure(s) Dependent variables included total time for removal of both QR side clips from the FM and success rate for removal of both side clips. Results The overall success rate for removal of both clips was 94.8% (164/173), whereas the mean times for removal of both clips ranged from 9.92 ± 12.06 seconds to 16.65 ± 20.97 seconds over 4 trial sessions. We found no differences among mean times for trial sessions throughout the season of play among the same helmets or among different helmets (P > .05). Conclusions Removal time and success rate of the Riddell QR were satisfactory during and after 1 season of play despite use in various temperatures and precipitation. PMID:22889658

  7. The contribution of CLIP2 haploinsufficiency to the clinical manifestations of the Williams-Beuren syndrome.

    Science.gov (United States)

    Vandeweyer, Geert; Van der Aa, Nathalie; Reyniers, Edwin; Kooy, R Frank

    2012-06-08

    Williams-Beuren syndrome is a rare contiguous gene syndrome, characterized by intellectual disability, facial dysmorphisms, connective-tissue abnormalities, cardiac defects, structural brain abnormalities, and transient infantile hypercalcemia. Genes lying telomeric to RFC2, including CLIP2, GTF2I and GTF2IRD1, are currently thought to be the most likely major contributors to the typical Williams syndrome cognitive profile, characterized by a better-than-expected auditory rote-memory ability, a relative sparing of language capabilities, and a severe visual-spatial constructive impairment. Atypical deletions in the region have helped to establish genotype-phenotype correlations. So far, however, hardly any deletions affecting only a single gene in the disease region have been described. We present here two healthy siblings with a pure, hemizygous deletion of CLIP2. A putative role in the cognitive and behavioral abnormalities seen in Williams-Beuren patients has been suggested for this gene on the basis of observations in a knock-out mouse model. The presented siblings did not show any of the clinical features associated with the syndrome. Cognitive testing showed an average IQ for both and no indication of the Williams syndrome cognitive profile. This shows that CLIP2 haploinsufficiency by itself does not lead to the physical or cognitive characteristics of the Williams-Beuren syndrome, nor does it lead to the Williams syndrome cognitive profile. Although contribution of CLIP2 to the phenotype cannot be excluded when it is deleted in combination with other genes, our results support the hypothesis that GTF2IRD1 and GTF2I are the main genes causing the cognitive defects associated with Williams-Beuren syndrome. Copyright © 2012 The American Society of Human Genetics. Published by Elsevier Inc. All rights reserved.

  8. Electroencephalography Amplitude Modulation Analysis for Automated Affective Tagging of Music Video Clips

    Directory of Open Access Journals (Sweden)

    Andrea Clerico

    2018-01-01

    Full Text Available The quantity of music content is rapidly increasing and automated affective tagging of music video clips can enable the development of intelligent retrieval, music recommendation, automatic playlist generators, and music browsing interfaces tuned to the users' current desires, preferences, or affective states. To achieve this goal, the field of affective computing has emerged, in particular the development of so-called affective brain-computer interfaces, which measure the user's affective state directly from measured brain waves using non-invasive tools, such as electroencephalography (EEG. Typically, conventional features extracted from the EEG signal have been used, such as frequency subband powers and/or inter-hemispheric power asymmetry indices. More recently, the coupling between EEG and peripheral physiological signals, such as the galvanic skin response (GSR, have also been proposed. Here, we show the importance of EEG amplitude modulations and propose several new features that measure the amplitude-amplitude cross-frequency coupling per EEG electrode, as well as linear and non-linear connections between multiple electrode pairs. When tested on a publicly available dataset of music video clips tagged with subjective affective ratings, support vector classifiers trained on the proposed features were shown to outperform those trained on conventional benchmark EEG features by as much as 6, 20, 8, and 7% for arousal, valence, dominance and liking, respectively. Moreover, fusion of the proposed features with EEG-GSR coupling features showed to be particularly useful for arousal (feature-level fusion and liking (decision-level fusion prediction. Together, these findings show the importance of the proposed features to characterize human affective states during music clip watching.

  9. Longline Observer (HI & Am. Samoa) Opah Fin Clip Collection for Lampris spp. Distribution Study

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Data set containing information collected from the 1000+ fin clips collected by Hawaii & American Samoa Longline Observers that will be used to analyze the...

  10. Post-clip placement MRI following second-look US-guided core biopsy for suspicious lesions identified on breast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Song, Sung Eun [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Korea University Anam Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Cho, Nariya [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Centre, Institute of Radiation Medicine, Seoul (Korea, Republic of); Han, Wonshik [Seoul National University Hospital, Department of Surgery, Seoul (Korea, Republic of)

    2017-12-15

    To evaluate whether the post-clip placement MRI following second-look ultrasound (US)-guided core biopsy is useful to confirm the adequate sampling of suspicious lesions identified on breast MRI. Between 2014 and 2016, 31 consecutive women with 34 suspicious lesions that had not been identified on previous mammography or US were detected using MRI. Among them, 26 women with 29 lesions (mean size 1.5 cm, range 0.5-5.8 cm) found by second-look US underwent US-guided biopsy, subsequent clip insertion and post-clip placement MRI. Five women with five lesions that were not found by second-look US underwent MRI-guided biopsy. The technical success rate and lesion characteristics were described. The technical success rate was 96.6% (28/29). One failure case was a benign, 1.1-cm non-mass enhancement. Of the 28 success cases, 23 (82.1%) were masses and 5 (17.9%) were non-mass enhancements; 17 (60.7%) were benign, 4 (14.3%) were high-risk and 7 (25.0%) were malignant lesions. The technical success rate was 100% (28/28) for masses and 83.3% (5/6) for non-mass enhancements. Post-clip placement MRI following US-guided biopsy is useful in confirming the adequate sampling of lesions identified on MRI. This method could be an alternative to MRI-guided biopsy for lesions visible on US. (orig.)

  11. Post-clip placement MRI following second-look US-guided core biopsy for suspicious lesions identified on breast MRI

    International Nuclear Information System (INIS)

    Song, Sung Eun; Cho, Nariya; Han, Wonshik

    2017-01-01

    To evaluate whether the post-clip placement MRI following second-look ultrasound (US)-guided core biopsy is useful to confirm the adequate sampling of suspicious lesions identified on breast MRI. Between 2014 and 2016, 31 consecutive women with 34 suspicious lesions that had not been identified on previous mammography or US were detected using MRI. Among them, 26 women with 29 lesions (mean size 1.5 cm, range 0.5-5.8 cm) found by second-look US underwent US-guided biopsy, subsequent clip insertion and post-clip placement MRI. Five women with five lesions that were not found by second-look US underwent MRI-guided biopsy. The technical success rate and lesion characteristics were described. The technical success rate was 96.6% (28/29). One failure case was a benign, 1.1-cm non-mass enhancement. Of the 28 success cases, 23 (82.1%) were masses and 5 (17.9%) were non-mass enhancements; 17 (60.7%) were benign, 4 (14.3%) were high-risk and 7 (25.0%) were malignant lesions. The technical success rate was 100% (28/28) for masses and 83.3% (5/6) for non-mass enhancements. Post-clip placement MRI following US-guided biopsy is useful in confirming the adequate sampling of lesions identified on MRI. This method could be an alternative to MRI-guided biopsy for lesions visible on US. (orig.)

  12. Microsurgical clipping of ophthalmic artery aneurysms: surgical results and visual outcomes with 208 aneurysms.

    Science.gov (United States)

    Kamide, Tomoya; Tabani, Halima; Safaee, Michael M; Burkhardt, Jan-Karl; Lawton, Michael T

    2018-01-26

    OBJECTIVE While most paraclinoid aneurysms can be clipped with excellent results, new postoperative visual deficits are a concern. New technology, including flow diverters, has increased the popularity of endovascular therapy. However, endovascular treatment of paraclinoid aneurysms is not without procedural risks, is associated with higher rates of incomplete aneurysm occlusion and recurrence, and may not address optic nerve compression symptoms that surgical debulking can. The increasing endovascular management of paraclinoid aneurysms should be justified by comparisons to surgical benchmarks. The authors, therefore, undertook this study to define patient, visual, and aneurysm outcomes in the most common type of paraclinoid aneurysm: ophthalmic artery (OphA) aneurysms. METHODS Results from microsurgical clipping of 208 OphA aneurysms in 198 patients were retrospectively reviewed. Patient demographics, aneurysm morphology (size, calcification, etc.), clinical characteristics, and patient outcomes were recorded and analyzed. RESULTS Despite 20% of these aneurysms being large or giant in size, complete aneurysm occlusion was accomplished in 91% of 208 cases, with OphA patency preserved in 99.5%. The aneurysm recurrence rate was 3.1% and the retreatment rate was 0%. Good outcomes (modified Rankin Scale score 0-2) were observed in 96.2% of patients overall and in all 156 patients with unruptured aneurysms. New visual field defects (hemianopsia or quadrantanopsia) were observed in 8 patients (3.8%), decreased visual acuity in 5 (2.4%), and monocular blindness in 9 (4.3%). Vision improved in 9 (52.9%) of the 17 patients with preoperative visual deficits. CONCLUSIONS The most important risk associated with clipping OphA aneurysms is a new visual deficit. Meticulous microsurgical technique is necessary during anterior clinoidectomy, aneurysm dissection, and clip application to optimize visual outcomes, and aggressive medical management postoperatively might potentially

  13. Investigation of Sequence Clipping and Structural Heterogeneity of an HIV Broadly Neutralizing Antibody by a Comprehensive LC-MS Analysis

    Science.gov (United States)

    Ivleva, Vera B.; Schneck, Nicole A.; Gollapudi, Deepika; Arnold, Frank; Cooper, Jonathan W.; Lei, Q. Paula

    2018-05-01

    CAP256 is one of the highly potent, broadly neutralizing monoclonal antibodies (bNAb) designed for HIV-1 therapy. During the process development of one of the constructs, an unexpected product-related impurity was observed via microfluidics gel electrophoresis. A panel of complementary LC-MS analyses was applied for the comprehensive characterization of CAP256 which included the analysis of the intact and reduced protein, the middle-up approach, and a set of complementary peptide mapping techniques and verification of the disulfide bonds. The designed workflow allowed to identify a clip within a protruding acidic loop in the CDR-H3 region of the heavy chain, which can lead to the decrease of bNAb potency. This characterization explained the origin of the additional species reflected by the reducing gel profile. An intra-loop disulfide bond linking the two fragments was identified, which explained why the non-reducing capillary electrophoresis (CE) profile was not affected. The extensive characterization of CAP256 post-translational modifications was performed to investigate a possible cause of CE profile complexity and to illustrate other structural details related to this molecule's biological function. Two sites of the engineered Tyr sulfation were verified in the antigen-binding loop, and pyroglutamate formation was used as a tool for monitoring the extent of antibody clipping. Overall, the comprehensive LC-MS study was crucial to (1) identify the impurity as sequence clipping, (2) pinpoint the clipping location and justify its susceptibility relative to the molecular structure, (3) lead to an upstream process optimization to mitigate product quality risk, and (4) ultimately re-engineer the sequence to be clip-resistant. [Figure not available: see fulltext.

  14. Response of Advance Cherrybark Oak Reproduction to Midstory Removal and Shoot Clipping

    Science.gov (United States)

    Brian R. Lockhart; John D. Hodges; Emile S. Gardiner

    2000-01-01

    A Midstory competition control and shoot clipping have been proposed to increase the vigor and height of advance bottomland oak reproduction. Results from a study in east-central Mississippi showed that advance cherrybark oak (Quercus pagoda Raf) released from midstory competition had greater survival than nonreleased seedlings, 64% and 48%,...

  15. [Ligation of the retrobulbar vascular-nervous bunch during performance of evisceration and enucleation using titanic clips in ophthalmic surgery].

    Science.gov (United States)

    Rykov, S A; Torchinskaia, N V; Bakbardina, I I; Simchuk, I V

    2011-10-01

    The efficacy of hemostasis achievement during conduction of a retrobulbar vascular-nervous bunch ligation (RVNBL), using titanic clips while evisceroenucleation performance, was studied up. A comparative analysis of clinical and functional results of surgical treatment of 36 patients, suffering terminal dolorous glaucoma and disaster of a sympathetic ophthalmia complication after an eye penetrating wounding occurrence. In 16 patients (the first group) a standard method of a hemostasis achievement was used while doing evisceroenucleation - a deep orbital tamponade for 5 minutes. In 20 patients (the second group) a procedure of RVNBL was conducted, using titanic clips before the bunch transsection doing. There was established, that while doing a RVNPL using titanic clips, a hemorrhage never occurs, a retrobulbar hematoma do not formated, the soft tissues reaction in the early postoperative period is less pronounced, and the patients postoperative rehabilitation period shortens.

  16. Results from extrapleural clipping of a patent ductus arteriosus in seriously ill preterm infants.

    Science.gov (United States)

    Demirturk, Orhan; Güvener, Murat; Coşkun, Isa; Tünel, Hüseyin Ali

    2011-12-01

    Minithoracotomy for extrapleural closure of the patent ductus arteriosus (PDA) in seriously ill patients offers a fast and less invasive alternative to conventional transpleural ductal closure. This study reports the immediate postoperative clinical outcomes for 24 extrapleurally clipped premature infants presenting with congestive heart failure in high-risk comorbidity status between March 2007 and November 2010. The demographics, preoperative clinical characteristics, and postoperative outcomes of the patients, including echocardiographic assessments, were evaluated. No surgery-related mortalities occurred. Four mortalities occurred after surgery due to sepsis and bleeding diathesis. All 20 surviving patients exhibited normal left ventricular dimensions and systolic function in the immediate follow-up period. The study shows that extrapleural clip closure in seriously ill premature infants has an acceptable overall short-term mortality and complication rate with a high rate of ductal closure.

  17. Microanalysis on selected video clips with focus on communicative response in music therapy

    DEFF Research Database (Denmark)

    Ridder, Hanne Mette Ochsner

    2007-01-01

    This chapter describes a five-step procedure for video analysis where the topic of investigation is the communicative response of clients in music therapy. In this microanalysis procedure only very short video clips are used, and in order to select these clips an overview of each music therapy...... session is obtained with the help of a session-graph that is a systematic way of collecting video observations from one music therapy session and combining the data in one figure. The systematic procedures do not demand sophisticated computer equipment; only standard programmes such as Excel and a media...... player. They are based on individual music therapy work with a population who are difficult to engage in joint activities and who show little response (e.g. persons suffering from severe dementia). The video analysis tools might be relevant to other groups of clients where it is important to form a clear...

  18. L'uso del doppiaggio e del sottotitolaggio nell'insegnamento della L2: Il caso della piattaforma ClipFlair

    Directory of Open Access Journals (Sweden)

    Lupe Romero

    2016-01-01

    Full Text Available Abstract – The purpose of this paper is to present the Clipflair project, a web platform for foreign language learning (FLL through revoicing and captioning of clips. Using audiovisual material in the language classroom is a common resource for teachers since it introduces variety, provides exposure to nonverbal cultural elements and, most importantly, presents linguistic and cultural aspects of communication in their context. However, teachers using this resource face the difficulty of finding active tasks that will engage learners and discourage passive viewing. ClipFlair proposes working with AV material productively while also motivating learners by getting them to revoice or caption a clip. Revoicing is a term used to refer to (rerecording voice onto a clip, as in dubbing, free commentary, audio description and karaoke singing. The term captioning refers to adding written text to a clip, such as standard subtitles, annotations and intertitles. Clips can be short video or audio files, including documentaries, film scenes, news pieces, animations and songs. ClipFlair develops materials that enable foreign language learners to practice all four standard CEFR skills: writing, speaking, listening and reading. Within the project’s scope, more than 350 ready-made activities, which involve captioning and/or revoicing of clips, has been created. These activities has been created for more than 16 languages including English, Spanish and Italian, but focus is placed on less widely taught languages, namely Estonian, Greek, Romanian and Polish, as well as minority languages, i.e. Basque, Catalan and Irish. Non-European languages, namely Arabic, Chinese, Japanese, Russian and Ukrainian are also included. The platform has three different areas: The Gallery offers the materials and the activities; the Studio area, offers a captioning and revoicing tools, in order to create or practice and learn languages by using the activities; the Social Network area

  19. Supra-orbital keyhole removal of anterior fossa and parasellar meningiomas Minicraniotomia supra-orbitária superciliar no tratamento de meningiomas na fossa craniana anterior e para-selares

    Directory of Open Access Journals (Sweden)

    Manoel Antonio de Paiva-Neto

    2010-06-01

    Full Text Available The improvement of surgical techniques as well as the introduction of new surgical instruments promoted the use of keyhole craniotomies in neurosurgery. We evaluated the technical aspects of the supra-orbital keyhole approach considering the indications, limitations, and complications of this approach to treat anterior cranial fossa and parasellar meningiomas. Twenty-four patients (21 females; mean age, 53±8.6 years operated on between 2002 and 2006 through a supra-orbital eyebrow approach were studied. Maximal tumor diameter ranged from 1.6 to 6 cm. Gross total resection was done in 20 (83.3%. All tumors were histologically benign. Two patients (8% experienced CSF rinorhea and another two patients suffered transitory diabetes insipidus (8%. One patient experienced transitory hemiparesis. There was one case of meningitis and one mortality. Follow-up ranged between 6 to 66 months (mean 31.5±20.1 months, with no recurrence. The supra-orbital keyhole craniotomy is a useful minimally invasive approach to treat selected anterior fossa and parasellar meningiomas.A evolução técnica e a introdução de instrumentais cirúrgicos mais delicados proporcionaram o uso de craniotomias menores no tratamento de patologias intracranianas. Avaliamos os aspectos técnicos da minicraniotomia supra-orbitária superciliar, considerando as indicações, limitações e complicações no tratamento de meningiomas na fossa craniana anterior e para-selares. Vinte e quarto pacientes (21 mulheres; idade média, 53±8,6 anos operados entre 2002 e 2006 foram estudados. O diâmetro tumoral máximo variou de 1,6 a 6 cm. Ressecção total foi obtida em 20 (83,3%. Todos os tumores eram histologicamente benignos. Dois pacientes (8% apresentaram fistula liquórica pós-operatória e outros dois diabetes insipido transitórioa (8%. Um paciente evoluiu com hemiparesia transitória. Houve um caso de meningite e um de evolução fatal. O seguimento variou de 6 a 66 meses (m

  20. Effect of HI-6 on cytokines production after immunity stimulation by keyhole limpet hemocyanin in a mouse model.

    Science.gov (United States)

    Pohanka, Miroslav

    2014-01-01

    HI-6 or asoxime in some sources is an antidotum for nerve agents. In recent experiments, implication of HI-6 in immunity response was proved; however, the issue was not studied in details. In this experiment, role of cytokines in HI-6 impact on immunity was searched. DESIG N: BALB/c mice were exposed to saline, HI-6 in a dose 1-100 mg/kg and/or 1 keyhole limpet hemocyanin (KLH) 1 mg/kg. Mice were sacrificed 21 days after experiment beginning and interleukins (IL) 1, 2, 4, 6 were determined by Enzyme Linked Immunosorbent Assay (ELISA). The animals had no pathological manifestation. From the tested cytokines, no significant alteration was found for the IL-1, IL-4 and IL-6. IL-2 was significantly increased in a dose response manner. The experimental data well correlates with the previous work where HI-6 caused increase of antibodies production. HI-6 is suitable to be used as an adjuvant whenever immunity should be pharmacologically altered.

  1. ThermaCELL and OFF! Clip-On Devices Tested for Repellency and Mortality Against Amblyomma americanum (Acari: Ixodida: Amblyommidae).

    Science.gov (United States)

    Bibbs, Christopher S; Xue, Rui-De

    2016-07-01

    The ThermaCELL with allethrin and OFF! Clip-on with metofluthrin were tested in a 939 m 2 vented enclosure against nymphal lone star ticks, Amblyomma americanum (L.). Repellency assays were conducted at varying distances relative to product specifications for repellency range. Nymphal ticks acclimated for 24 h in chambers attached to 10 repellency tracks per repetition. Devices were turned on, and the tick travel distance and delay until beginning to travel were recorded. Mortality of ticks was recorded after 24 h. Mortality assays were also conducted at the same distances with five ticks per cage, and 12 cages per distance radially distributed around a device. Cages were removed after 5 min, 15 min, 30 min, and 60 min of exposure and checked after 24 h for mortality. Significant travel distance was found when exposed to the ThermaCELL and OFF! Clip-on at their shortest test distances. Significant mortality also resulted at the same distances. Ticks exposed to active devices for longer than 15 min had significant mortality at the shortest distance for OFF! Clip-on and multiple distances for the ThermaCELL. Overall, the spatial repellent devices ThermaCELL with allethrin and OFF! Clip-on with metofluthrin both demonstrated desirable effects when tested against A. americanum nymphs. © The Authors 2016. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. A combination of selected mapping and clipping to increase energy efficiency of OFDM systems

    Science.gov (United States)

    Lee, Byung Moo; Rim, You Seung

    2017-01-01

    We propose an energy efficient combination design for OFDM systems based on selected mapping (SLM) and clipping peak-to-average power ratio (PAPR) reduction techniques, and show the related energy efficiency (EE) performance analysis. The combination of two different PAPR reduction techniques can provide a significant benefit in increasing EE, because it can take advantages of both techniques. For the combination, we choose the clipping and SLM techniques, since the former technique is quite simple and effective, and the latter technique does not cause any signal distortion. We provide the structure and the systematic operating method, and show the various analyzes to derive the EE gain based on the combined technique. Our analysis show that the combined technique increases the EE by 69% compared to no PAPR reduction, and by 19.34% compared to only using SLM technique. PMID:29023591

  3. Resolution of Oculomotor Nerve Palsy Secondary to Posterior Communicating Artery Aneurysms: Comparison of Clipping and Coiling.

    Science.gov (United States)

    McCracken, D Jay; Lovasik, Brendan P; McCracken, Courtney E; Caplan, Justin M; Turan, Nefize; Nogueira, Raul G; Cawley, C Michael; Dion, Jacques E; Tamargo, Rafael J; Barrow, Daniel L; Pradilla, Gustavo

    2015-12-01

    Previous studies have attempted to determine the best treatment for oculomotor nerve palsy (ONP) secondary to posterior communicating artery (PCoA) aneurysms, but have been limited by small sample sizes and limited treatment. To analyze the treatment of ONP secondary to PCoA with both coiling and clipping in ruptured and unruptured aneurysms. Data from 2 large academic centers was retrospectively collected over 22 years, yielding a total of 93 patients with ONP secondary to PCoA aneurysms. These patients were combined with 321 patients from the literature review for large data analyses. Onset symptoms, recovery, and time to resolution were evaluated with respect to treatment and aneurysm rupture status. For all patients presenting with ONP (n = 414) 56.6% of those treated with microsurgical clipping made a full recovery vs 41.5% of those treated with endovascular coil embolization (P = .02). Of patients with a complete ONP (n = 229), full recovery occurred in 47.3% of those treated with clipping but in only 20% of those undergoing coiling (P = .01). For patients presenting with ruptured aneurysms (n = 130), full recovery occurred in 70.9% compared with 49.3% coiled patients (P = .01). Additionally, although patients with full ONP recovery had a median time to treatment of 4 days, those without full ONP recovery had a median time to treatment of 7 days (P = .01). Patients with ONP secondary to PCoA aneurysms treated with clipping showed higher rates of full ONP resolution than patients treated with coil embolization. Larger prospective studies are needed to determine the true potential of recovery associated with each treatment. EUH, Emory University HospitalIQR, interquartile rangeJHU, Johns Hopkins UniversitymRS, modified Rankin ScaleONP, oculomotor nerve palsyPCoA, posterior communicating arterySAH, subarachnoid hemorrhage.

  4. Predicting Factors of Chronic Subdural Hematoma Following Surgical Clipping in Unruptured and Ruptured Intracranial Aneurysm.

    Science.gov (United States)

    Kwon, Min-Yong; Kim, Chang-Hyun; Lee, Chang-Young

    2016-09-01

    The aim of this study is to analyze the differences in the incidence, predicting factors, and clinical course of chronic subdural hematoma (CSDH) following surgical clipping between unruptured (UIA) and ruptured intracranial aneurysm (RIA). We conducted a retrospective analysis of 752 patients (UIA : 368 and RIA : 384) who underwent surgical clipping during 8 years. The incidence and predicting factors of CSDH development in the UIA and RIA were compared according to medical records and radiological data. The incidence of postoperative CSDH was higher in the UIA (10.9%) than in the RIA (3.1%) (p=0.000). In multivariate analysis, a high Hounsfield (HF) unit (blood clots) for subdural fluid collection (SFC), persistence of SFC ≥5 mm and male sex in the UIA and A high HF unit for SFC and SFC ≥5 mm without progression to hydrocephalus in the RIA were identified as the independent predicting factors for CSDH development (psubdural space and persistence of SFC ≥5 mm were predicting factors in both UIA and RIA. However, progression to hydrocephalus may have in part contributed to low CSDH development in the RIA. We suggest that cleaning of blood clots in the subdural space and efforts to minimize SFC ≥5 mm at the end of surgery is helpful to prevent CSDH following aneurysmal clipping.

  5. Role of motor-evoked potential monitoring in conjunction with temporary clipping of spinal nerve roots in posterior thoracic spine tumor surgery.

    Science.gov (United States)

    Eleraky, Mohammed A; Setzer, Matthias; Papanastassiou, Ioannis D; Baaj, Ali A; Tran, Nam D; Katsares, Kiesha M; Vrionis, Frank D

    2010-05-01

    The vascular supply of the thoracic spinal cord depends on the thoracolumbar segmental arteries. Because of the small size and ventral course of these arteries in relation to the dorsal root ganglion and ventral root, they cannot be reliably identified during surgery by anatomic or morphologic criteria. Sacrificing them will most likely result in paraplegia. The goal of this study was to evaluate a novel method of intraoperative testing of a nerve root's contribution to the blood supply of the thoracic spinal cord. This is a clinical retrospective study of 49 patients diagnosed with thoracic spine tumors. Temporary nerve root clipping combined with motor-evoked potential (MEP) and somatosensory-evoked potential (SSEP) monitoring was performed; additionally, postoperative clinical evaluation was done and reported in all cases. All cases were monitored by SSEP and MEPs. The nerve root to be sacrificed was temporarily clipped using standard aneurysm clips, and SSEP/MEP were assessed before and after clipping. Four nerve roots were sacrificed in four cases, three nerve roots in eight cases, and two nerve roots in 22 cases. Nerve roots were sacrificed bilaterally in 12 cases. Most patients (47/49) had no changes in MEP/SSEP and had no neurological deficit postoperatively. One case of a spinal sarcoma demonstrated changes in MEP after temporary clipping of the left T11 nerve root. The nerve was not sacrificed, and the patient was neurologically intact after surgery. In another case of a sarcoma, MEPs changed in the lower limbs after ligation of left T9 nerve root. It was felt that it was a global event because of anesthesia. Postoperatively, the patient had complete paraplegia but recovered almost completely after 6 months. Temporary nerve root clipping combined with MEP and SSEP monitoring may enhance the impact of neuromonitoring in the intraoperative management of patients with thoracic spine tumors and favorably influence neurological outcome. Copyright 2010 Elsevier

  6. Efficacy of Handwashing with Soap and Nail Clipping on Intestinal Parasitic Infections in School-Aged Children: A Factorial Cluster Randomized Controlled Trial.

    Science.gov (United States)

    Mahmud, Mahmud Abdulkader; Spigt, Mark; Bezabih, Afework Mulugeta; Pavon, Ignacio Lopez; Dinant, Geert-Jan; Velasco, Roman Blanco

    2015-06-01

    Intestinal parasitic infections are highly endemic among school-aged children in resource-limited settings. To lower their impact, preventive measures should be implemented that are sustainable with available resources. The aim of this study was to assess the impact of handwashing with soap and nail clipping on the prevention of intestinal parasite reinfections. In this trial, 367 parasite-negative school-aged children (aged 6-15 y) were randomly assigned to receive both, one or the other, or neither of the interventions in a 2 × 2 factorial design. Assignment sequence was concealed. After 6 mo of follow-up, stool samples were examined using direct, concentration, and Kato-Katz methods. Hemoglobin levels were determined using a HemoCue spectrometer. The primary study outcomes were prevalence of intestinal parasite reinfection and infection intensity. The secondary outcome was anemia prevalence. Analysis was by intention to treat. Main effects were adjusted for sex, age, drinking water source, latrine use, pre-treatment parasites, handwashing with soap and nail clipping at baseline, and the other factor in the additive model. Fourteen percent (95% CI: 9% to 19%) of the children in the handwashing with soap intervention group were reinfected versus 29% (95% CI: 22% to 36%) in the groups with no handwashing with soap (adjusted odds ratio [AOR] 0.32, 95% CI: 0.17 to 0.62). Similarly, 17% (95% CI: 12% to 22%) of the children in the nail clipping intervention group were reinfected versus 26% (95% CI: 20% to 32%) in the groups with no nail clipping (AOR 0.51, 95% CI: 0.27 to 0.95). Likewise, following the intervention, 13% (95% CI: 8% to 18%) of the children in the handwashing group were anemic versus 23% (95% CI: 17% to 29%) in the groups with no handwashing with soap (AOR 0.39, 95% CI: 0.20 to 0.78). The prevalence of anemia did not differ significantly between children in the nail clipping group and those in the groups with no nail clipping (AOR 0.53, 95% CI: 0.27 to

  7. Efficacy of Handwashing with Soap and Nail Clipping on Intestinal Parasitic Infections in School-Aged Children: A Factorial Cluster Randomized Controlled Trial.

    Directory of Open Access Journals (Sweden)

    Mahmud Abdulkader Mahmud

    2015-06-01

    Full Text Available Intestinal parasitic infections are highly endemic among school-aged children in resource-limited settings. To lower their impact, preventive measures should be implemented that are sustainable with available resources. The aim of this study was to assess the impact of handwashing with soap and nail clipping on the prevention of intestinal parasite reinfections.In this trial, 367 parasite-negative school-aged children (aged 6-15 y were randomly assigned to receive both, one or the other, or neither of the interventions in a 2 × 2 factorial design. Assignment sequence was concealed. After 6 mo of follow-up, stool samples were examined using direct, concentration, and Kato-Katz methods. Hemoglobin levels were determined using a HemoCue spectrometer. The primary study outcomes were prevalence of intestinal parasite reinfection and infection intensity. The secondary outcome was anemia prevalence. Analysis was by intention to treat. Main effects were adjusted for sex, age, drinking water source, latrine use, pre-treatment parasites, handwashing with soap and nail clipping at baseline, and the other factor in the additive model. Fourteen percent (95% CI: 9% to 19% of the children in the handwashing with soap intervention group were reinfected versus 29% (95% CI: 22% to 36% in the groups with no handwashing with soap (adjusted odds ratio [AOR] 0.32, 95% CI: 0.17 to 0.62. Similarly, 17% (95% CI: 12% to 22% of the children in the nail clipping intervention group were reinfected versus 26% (95% CI: 20% to 32% in the groups with no nail clipping (AOR 0.51, 95% CI: 0.27 to 0.95. Likewise, following the intervention, 13% (95% CI: 8% to 18% of the children in the handwashing group were anemic versus 23% (95% CI: 17% to 29% in the groups with no handwashing with soap (AOR 0.39, 95% CI: 0.20 to 0.78. The prevalence of anemia did not differ significantly between children in the nail clipping group and those in the groups with no nail clipping (AOR 0.53, 95% CI

  8. Large window median filtering on Clip7

    Energy Technology Data Exchange (ETDEWEB)

    Mathews, K N

    1983-07-01

    Median filtering has been found to be a useful operation to perform on images in order to reduce random noise while preserving edges of objects. However, in some cases, as the resolution of the image increases, so too does the required window size of the filter. For parallel array processors, this leads to problems when dealing with the large amount of data involved. That is to say that there tend to be problems over slow access of data from pixels over a large neighbourhood, lack of available storage of this data during the operation and long computational times for finding the median. An algorithm for finding the median, designed for use on byte wide architecture parallel array processors is presented together with its implementation on Clip7, a scanning array of such processors. 6 references.

  9. Transcatheter treatment of severe tricuspid regurgitation with the MitraClip system.

    Science.gov (United States)

    Hammerstingl, Christoph; Schueler, Robert; Malasa, Margarita; Werner, Nikos; Nickenig, Georg

    2016-03-07

    The aim of this study was to show technical principles and feasibility of transcatheter tricuspid valve repair by use of the MitraClip system. Three consecutive patients were treated successfully for severe symptomatic Tricuspid regurgitation. Three-dimensional transoesophageal echocardiography confirmed reduction of measured effective regurgitant orifice in all patients [effective regurgitant orifice area-baseline/post-procedure (cm(2)): 0.7/0.3; 1.5/0.8; 0.4/0.1], which was accompanied by an increase in left ventricular stroke volumes [baseline/post-procedure (mL): 42.8/45.4; 38/45; 35.2/45], decrease of measured levels of N terminal pro brain natriuretic peptide (pg/mL: baseline/post-procedure: 548/440; 2526/1702; 1754/623), and significant relief of clinical symptoms for chronic right heart failure in all patients. Transcatheter tricuspid valve repair by use of interventional edge-to-edge repair with the MitraClip system was feasible, and safe in three consecutive patients. Reduction of tricuspid insufficiency associates with relief of clinical symptoms for right heart failure. This strategy seems a promising treatment option for patients at prohibitive surgical risk. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  10. Establishing a protocol for element determination in human nail clippings by neutron activation analysis

    International Nuclear Information System (INIS)

    Sanches, Thalita Pinheiro; Saiki, Mitiko

    2011-01-01

    Human nail samples have been analyzed to evaluate occupational exposure, nutritional status and to diagnose certain diseases. However, sampling and washing protocols for nail analyses vary from study to study not allowing comparisons between studies. One of the difficulties in analyzing nail samples is to eliminate only surface contamination without removing elements of interest in this tissue. In the present study, a protocol was defined in order to obtain reliable results of element concentrations in human nail clippings. Nail clippings collected from all 10 fingers or toes were previously pre cleaned using an ethyl alcohol solution to eliminate microbes. Then, the clippings were cut in small pieces and submitted to different reagents for washing by shaking. Neutron activation analysis (NAA) was applied for nail samples analysis which consisted of irradiating aliquots of samples together with synthetic elemental standards in the IEA-R1 nuclear research reactor followed by gamma ray spectrometry. Comparisons made between the results obtained for nails submitted to different reagents for cleaning indicated that the procedure using acetone and Triton X100 solution is more effective than that of nitric acid solution. Analyses in triplicates of a nail sample indicated results with relative standard deviations lower than 15% for most of elements, showing the homogeneity of the prepared sample. Qualitative analyses of different nail polishes showed that the presence of elements determined in the present study is negligible in these products. Quality control of the analytical results indicated that the applied NAA procedure is adequate for human nail analysis. (author)

  11. Hemodynamic control of in patients with concomitant hypertensive disease during brain aneurysm clipping

    OpenAIRE

    Dzyuba, D.O.; Melnik, A.F.; Yavorsky, F.A.

    2018-01-01

    The article describes the state of the problem of hemodynamic control during brain aneurysm clipping in concomitant hypertensive disease. Author studies hemodynamic control by using magnesia therapy with the addition of clonidine solution and infusion of urapidil solution. Based on the results of the study, the advantages of urapidil infusion are given.

  12. Anterior communicating artery aneurysm clipping versus coiling: a comparative study of 50 cases

    Directory of Open Access Journals (Sweden)

    Kumar Pradeep

    2017-09-01

    Full Text Available Introduction: Aneurysmal Subarachnoid Hemorrhage (aSAH remains a devastating and often fatal form of stroke. The aneurysm is targeted for obliteration to prevent re-bleeding and to manage the possible complications from the event. Endovascular coiling has emerged as a less invasive alternative to conventional surgical clipping to treat aneurysms.

  13. Influence of percutaneous mitral valve repair using the MitraClip® system on renal function in patients with severe mitral regurgitation.

    Science.gov (United States)

    Rassaf, Tienush; Balzer, Jan; Rammos, Christos; Zeus, Tobias; Hellhammer, Katharina; v Hall, Silke; Wagstaff, Rabea; Kelm, Malte

    2015-04-01

    In patients with mitral regurgitation (MR), changes in cardiac stroke volume, and thus renal preload and afterload may affect kidney function. Percutaneous mitral valve repair (PMVR) with the MitraClip® system can be a therapeutic alternative to surgical valve repair. The influence of MitraClip® therapy on renal function and clinical outcome parameters is unknown. Sixty patients with severe MR underwent PMVR using the MitraClip® system in an open-label observational study. Patients were stratified according to their renal function. All clips have been implanted successfully. Effective reduction of MR by 2-3 grades acutely improved KDOQI class. Lesser MR reduction (MR reduction of 0-1 grades) led to worsening of renal function in patients with pre-existing normal or mild (KDOQI 1-2) compared to severe (KDOQI 3-4) renal dysfunction. Reduction of MR was associated with improvement in Minnesota Living with Heart Failure Questionnaire (MLHFQ), NYHA-stadium, and 6-minute walk test. Successful PMVR was associated with an improvement in renal function. The improvement in renal function was associated with the extent of MR reduction and pre-existing kidney dysfunction. Our data emphasize the relevance of PVMR to stabilize the cardiorenal axis in patients with severe MR. © 2014 Wiley Periodicals, Inc.

  14. Safety and efficacy of endoscopic submucosal dissection using IT knife nano with clip traction method for early esophageal squamous cell carcinoma.

    Science.gov (United States)

    Kitagawa, Yoshiyasu; Suzuki, Takuto; Hara, Taro; Yamaguchi, Taketo

    2018-01-01

    Although endoscopic submucosal dissection (ESD) is an accepted and established treatment for early esophageal squamous cell carcinoma (EESCC), it is technically difficult, time consuming, and less safe than endoscopic mucosal resection. To perform ESD safely and more efficiently, we proposed a new technique of esophageal ESD using an IT knife nano with the clip traction method. This study aimed to evaluate the efficacy and safety of ESD using this new technique. We retrospectively reviewed all consecutive cases of esophageal ESD performed using an IT knife nano with the clip traction method at our hospital between March 2013 and January 2017. Therapeutic efficacy and safety were also assessed. A total of 103 patients underwent esophageal ESD using the IT knife nano with the clip traction method. In all cases, we performed en bloc resection. Complete resection was achieved in 100 cases (97.1%). The median operating time was 40 (range 13-230) min. No cases of perforation or delayed bleeding occurred. Although two cases (2.0%) of mediastinal emphysema occurred without visible perforation at endoscopy, all were successfully managed conservatively. The new technique of esophageal ESD using the IT knife nano with the clip traction method appears to be feasible, effective, and safe for EESCC treatment.

  15. Enhanced subcarrier-index modulation-based asymmetrically clipped optical OFDM using even subcarriers

    Science.gov (United States)

    Guan, Rui; Xu, Wei; Yang, Zhaohui; Huang, Nuo; Wang, Jin-Yuan; Chen, Ming

    2017-11-01

    In this paper, we propose a subcarrier-index modulation-based asymmetrically clipped optical orthogonal frequency division multiplexing (SACO-OFDM) scheme for optical wireless communication (OWC) systems, which benefits from the subcarrier-index modulation (SIM) and asymmetrically clipped optical orthogonal frequency division multiplexing (ACO-OFDM) techniques. SACO-OFDM conveys additional information via the subcarrier indexing, and the error rate of the bit transmitted by the subcarrier indexing is much lower than that of the conventional M-ary modulation scheme. On the other hand, as the signal constellation in M-ary modulation is relieved, SACO-OFDM has simple transceiver structure and low detection complexity. Moreover, considering the spectral, an enhanced SACO-OFDM (ESACO-OFDM) using even subcarriers is proposed. In this technique, the odd subcarriers are activated for SACO-OFDM, and the imaginary part of even subcarriers are activated for pulse-amplitude-modulated discrete multitone (PAM-DMT). Clearly, ESACO-OFDM achieves better spectral efficiency than the conventional optical OFDM, since all subcarriers are used for data transmission. Simulation results verify the significant bit error rate (BER) and peak-to-average power ratio (PAPR) improvement by the proposed ESACO-OFDM, especially for the medium-to-high signal-to-noise ratio (SNR) regime.

  16. Level of headaches after surgical aneurysm clipping decreases significantly faster compared to endovascular coiled patients

    Directory of Open Access Journals (Sweden)

    Athanasios K. Petridis

    2017-04-01

    Full Text Available In incidental aneurysms, endovascular treatment can lead to post-procedural headaches. We studied the difference of surgical clipping vs. endovascular coiling in concern to post-procedural headaches in patients with ruptured aneurysms. Sixtyseven patients with aneurysmal subarachnoidal haemorrhage were treated in our department from September 1st 2015 - September 1st 2016. 43 Patients were included in the study and the rest was excluded because of late recovery or highgrade subarachnoid bleedings. Twenty-two were surgical treated and twenty-one were interventionally treated. We compared the post-procedural headaches at the time points of 24 h, 21 days, and 3 months after treatment using the visual analog scale (VAS for pain. After surgical clipping the headache score decreased for 8.8 points in the VAS, whereas the endovascular treated population showed a decrease of headaches of 3.3 points. This difference was highly statistical significant and remained significant even after 3 weeks where the pain score for the surgically treated patients was 0.68 and for the endovascular treated 1.8. After 3 months the pain was less than 1 for both groups with surgically treated patients scoring 0.1 and endovascular treated patients 0.9 (not significant. Clipping is relieving the headaches of patients with aneurysm rupture faster and more effective than endovascular coiling. This effect stays significant for at least 3 weeks and plays a crucial role in stress relieve during the acute and subacute ICU care of such patients.

  17. Comparison of Hematologic and Biochemical Test Results in Blood Samples Obtained by Jugular Venipuncture Versus Nail Clip in Moluccan Cockatoos (Cacatua moluccensis).

    Science.gov (United States)

    Bennett, Tracy D; Lejnieks, Daniel V; Koepke, Hoyt; Grimson, Fiona; Szucs, Jennifer; Omaits, Kerri; Lane, Rosalie

    2015-12-01

    In birds, blood samples are often collected from the jugular, medial metatarsal, and basilic vein. Samples are sometimes collected by toe nail clip, but concerns to avoid drawing blood from the nail include pain after nail clips for blood collection, potential differences in complete blood count (CBC) results, and potential contamination with uric acid values. To compare differences in biochemical and hematologic values in blood samples obtained by jugular venipuncture versus toenail clip, blood samples were collected from Moluccan cockatoos (Cacatua moluccensis) (N = 23) and sent to a commercial laboratory for routine CBCs and serum biochemical analysis. Results showed good agreement between venipuncture and nail clip blood samples in red blood cell count, packed cell volume, heterophil count and percentage, lymphocyte count and percentage, aspartate aminotransferase, chloride, creatine phosphokinase, glucose, lactate dehydrogenase, total protein, and uric acid values. Constant bias was found in values of bile acids, cholesterol, and hemoglobin. Proportional bias toward higher values in the jugular sample were found in total white blood cell (WBC) count and inorganic phosphorus. Serum calcium plots revealed a proportional bias toward higher values in the toe nail blood when values were increased. Results suggest some differences in WBC count, bile acids, calcium, cholesterol, hemoglobin, and phosphorus values between blood samples collected by jugular venipuncture and samples collected by toe nail clip, but the differences are mostly minor and, with the possible exception of inorganic phosphorus and marginally elevated or very low WBC counts, are unlikely to affect the use or interpretation of the avian blood panel.

  18. Cryoablation of lung malignancies recurring close to surgical clips following surgery: Report of three cases

    International Nuclear Information System (INIS)

    Grasso, Rosario F; Luppi, Giacomo; Cazzato, Roberto L; Vescovo, Riccardo Del; Giurazza, Francesco; Mercurio, Simona; Faiella, Eliodoro; Zobel, Bruno Beomonte

    2015-01-01

    Minimally ablative therapies are now available for the treatment of lung malignancies. However, selection of the appropriate technique is not always easy and requires accurate preoperative planning. To describe the treatment of lung tumors with cryoablation. We report three cases of lung malignancies that recurred close to surgical clips after surgical treatment, successfully treated by cryoablation. An initial freezing cycle was performed for 10 min, followed by a 5-min thawing cycle, and an additional 10-min freezing cycle. A final 5-min thaw was necessary to remove the needle from the iceball formed during the freezing cycle. The procedures were completed successfully with no signs of surgical-clip misplacement, and excellent ablation of the lesions. Cryoablation is a relatively new procedure that potentially permits the local treatment of lung tumors with minimal loss of lung parenchyma

  19. First- and third-party ground truth for key frame extraction from consumer video clips

    Science.gov (United States)

    Costello, Kathleen; Luo, Jiebo

    2007-02-01

    Extracting key frames (KF) from video is of great interest in many applications, such as video summary, video organization, video compression, and prints from video. KF extraction is not a new problem. However, current literature has been focused mainly on sports or news video. In the consumer video space, the biggest challenges for key frame selection from consumer videos are the unconstrained content and lack of any preimposed structure. In this study, we conduct ground truth collection of key frames from video clips taken by digital cameras (as opposed to camcorders) using both first- and third-party judges. The goals of this study are: (1) to create a reference database of video clips reasonably representative of the consumer video space; (2) to identify associated key frames by which automated algorithms can be compared and judged for effectiveness; and (3) to uncover the criteria used by both first- and thirdparty human judges so these criteria can influence algorithm design. The findings from these ground truths will be discussed.

  20. Usefulness of angiographic embolization endoscopic metallic clip placement in patient with non-variceal upper gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Min Jae; Hwang, Cheol Mog; Kim, Ho Jun; Cho, Young Jun; Bae, Seok Hwan [Dept. of Radiology, Konyang University Hospital, Daejeon (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young [Dept. of Radiology, Chungnam National University College of Medicine, Daejeon (Korea, Republic of); Kang, Chae Hoon [Dept. of Radiology, Inje University College of Medicine, Pusan Paik Hospital, Busan (Korea, Republic of)

    2013-08-15

    The aim of this study is to assess the usefulness of angiographic embolization after endoscopic metallic clip placement around the edge of non-variceal upper gastrointestinal bleeding ulcers. We have chosen 41 patients (mean age, 65.2 years) with acute bleeding ulcers (22 gastric ulcers, 16 duodenal ulcers, 3 malignant ulcers) between January 2010 and December 2012. We inserted metallic clips during the routine endoscopic treatments of the bleeding ulcers. Subsequent transcatheter arterial embolization was performed within 2 hours. We analyzed the angiographic positive rates, angiographic success rates and clinical success rates. Among the 41 patients during the angiography, 19 patients (46%) demonstrated active bleeding points. Both groups underwent embolization using microcoils, N-butyl-cyano-acrylate (NBCA), microcoils with NBCA or gelfoam particle. There are no statistically significant differences between these two groups according to which embolic materials are being used. The bleeding was initially stopped in all patients, except the two who experienced technical failures. Seven patients experienced repeated episodes of bleeding within two weeks. Among them, 4 patients were successful re-embolized. Another 3 patients underwent gastrectomy. Overall, clinical success was achieved in 36 of 41 (87.8%) patients. The endoscopic metallic clip placement was helpful to locate the correct target vessels for the angiographic embolization. In conclusion, this technique reduced re-bleeding rates, especially in patients who do not show active bleeding points.

  1. Discovery of Protein–lncRNA Interactions by Integrating Large-Scale CLIP-Seq and RNA-Seq Datasets

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jun-Hao; Liu, Shun; Zheng, Ling-Ling; Wu, Jie; Sun, Wen-Ju; Wang, Ze-Lin; Zhou, Hui; Qu, Liang-Hu, E-mail: lssqlh@mail.sysu.edu.cn; Yang, Jian-Hua, E-mail: lssqlh@mail.sysu.edu.cn [RNA Information Center, Key Laboratory of Gene Engineering of the Ministry of Education, State Key Laboratory for Biocontrol, Sun Yat-sen University, Guangzhou (China)

    2015-01-14

    Long non-coding RNAs (lncRNAs) are emerging as important regulatory molecules in developmental, physiological, and pathological processes. However, the precise mechanism and functions of most of lncRNAs remain largely unknown. Recent advances in high-throughput sequencing of immunoprecipitated RNAs after cross-linking (CLIP-Seq) provide powerful ways to identify biologically relevant protein–lncRNA interactions. In this study, by analyzing millions of RNA-binding protein (RBP) binding sites from 117 CLIP-Seq datasets generated by 50 independent studies, we identified 22,735 RBP–lncRNA regulatory relationships. We found that one single lncRNA will generally be bound and regulated by one or multiple RBPs, the combination of which may coordinately regulate gene expression. We also revealed the expression correlation of these interaction networks by mining expression profiles of over 6000 normal and tumor samples from 14 cancer types. Our combined analysis of CLIP-Seq data and genome-wide association studies data discovered hundreds of disease-related single nucleotide polymorphisms resided in the RBP binding sites of lncRNAs. Finally, we developed interactive web implementations to provide visualization, analysis, and downloading of the aforementioned large-scale datasets. Our study represented an important step in identification and analysis of RBP–lncRNA interactions and showed that these interactions may play crucial roles in cancer and genetic diseases.

  2. Usefulness of angiographic embolization endoscopic metallic clip placement in patient with non-variceal upper gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Yoon, Min Jae; Hwang, Cheol Mog; Kim, Ho Jun; Cho, Young Jun; Bae, Seok Hwan; Shin, Byung Seok; Ohm, Joon Young; Kang, Chae Hoon

    2013-01-01

    The aim of this study is to assess the usefulness of angiographic embolization after endoscopic metallic clip placement around the edge of non-variceal upper gastrointestinal bleeding ulcers. We have chosen 41 patients (mean age, 65.2 years) with acute bleeding ulcers (22 gastric ulcers, 16 duodenal ulcers, 3 malignant ulcers) between January 2010 and December 2012. We inserted metallic clips during the routine endoscopic treatments of the bleeding ulcers. Subsequent transcatheter arterial embolization was performed within 2 hours. We analyzed the angiographic positive rates, angiographic success rates and clinical success rates. Among the 41 patients during the angiography, 19 patients (46%) demonstrated active bleeding points. Both groups underwent embolization using microcoils, N-butyl-cyano-acrylate (NBCA), microcoils with NBCA or gelfoam particle. There are no statistically significant differences between these two groups according to which embolic materials are being used. The bleeding was initially stopped in all patients, except the two who experienced technical failures. Seven patients experienced repeated episodes of bleeding within two weeks. Among them, 4 patients were successful re-embolized. Another 3 patients underwent gastrectomy. Overall, clinical success was achieved in 36 of 41 (87.8%) patients. The endoscopic metallic clip placement was helpful to locate the correct target vessels for the angiographic embolization. In conclusion, this technique reduced re-bleeding rates, especially in patients who do not show active bleeding points.

  3. Discovery of Protein–lncRNA Interactions by Integrating Large-Scale CLIP-Seq and RNA-Seq Datasets

    International Nuclear Information System (INIS)

    Li, Jun-Hao; Liu, Shun; Zheng, Ling-Ling; Wu, Jie; Sun, Wen-Ju; Wang, Ze-Lin; Zhou, Hui; Qu, Liang-Hu; Yang, Jian-Hua

    2015-01-01

    Long non-coding RNAs (lncRNAs) are emerging as important regulatory molecules in developmental, physiological, and pathological processes. However, the precise mechanism and functions of most of lncRNAs remain largely unknown. Recent advances in high-throughput sequencing of immunoprecipitated RNAs after cross-linking (CLIP-Seq) provide powerful ways to identify biologically relevant protein–lncRNA interactions. In this study, by analyzing millions of RNA-binding protein (RBP) binding sites from 117 CLIP-Seq datasets generated by 50 independent studies, we identified 22,735 RBP–lncRNA regulatory relationships. We found that one single lncRNA will generally be bound and regulated by one or multiple RBPs, the combination of which may coordinately regulate gene expression. We also revealed the expression correlation of these interaction networks by mining expression profiles of over 6000 normal and tumor samples from 14 cancer types. Our combined analysis of CLIP-Seq data and genome-wide association studies data discovered hundreds of disease-related single nucleotide polymorphisms resided in the RBP binding sites of lncRNAs. Finally, we developed interactive web implementations to provide visualization, analysis, and downloading of the aforementioned large-scale datasets. Our study represented an important step in identification and analysis of RBP–lncRNA interactions and showed that these interactions may play crucial roles in cancer and genetic diseases.

  4. Judgments of Nonverbal Behaviour by Children with High-Functioning Autism Spectrum Disorder: Can They Detect Signs of Winning and Losing from Brief Video Clips?

    Science.gov (United States)

    Ryan, Christian; Furley, Philip; Mulhall, Kathleen

    2016-01-01

    Typically developing children are able to judge who is winning or losing from very short clips of video footage of behaviour between active match play across a number of sports. Inferences from "thin slices" (short video clips) allow participants to make complex judgments about the meaning of posture, gesture and body language. This…

  5. Metallic clip migration to the common bile duct after laparoscopic surgery of the gallbladder

    International Nuclear Information System (INIS)

    Mendoza, Monica E.; Bauni, Carlos E.; Vives, Daniel A.

    2001-01-01

    We report a case of a 65 years old man with jaundice and cholangitis, appeared 8 month after laparoscopic cholecystectomy. CT demonstrated a surgical endo-clip migrated into the common bile duct. CT diagnosis was accurate. The patient had a good clinical evolution after successful endoscopic therapy. (author)

  6. Straight trajectory planning for keyhole neurosurgery in sheep with automatic brain structures segmentation

    Science.gov (United States)

    Favaro, Alberto; Lad, Akash; Formenti, Davide; Zani, Davide Danilo; De Momi, Elena

    2017-03-01

    In a translational neuroscience/neurosurgery perspective, sheep are considered good candidates to study because of the similarity between their brain and the human one. Automatic planning systems for safe keyhole neurosurgery maximize the probe/catheter distance from vessels and risky structures. This work consists in the development of a trajectories planner for straight catheters placement intended to be used for investigating the drug diffusivity mechanisms in sheep brain. Automatic brain segmentation of gray matter, white matter and cerebrospinal fluid is achieved using an online available sheep atlas. Ventricles, midbrain and cerebellum segmentation have been also carried out. The veterinary surgeon is asked to select a target point within the white matter to be reached by the probe and to define an entry area on the brain cortex. To mitigate the risk of hemorrhage during the insertion process, which can prevent the success of the insertion procedure, the trajectory planner performs a curvature analysis of the brain cortex and wipes out from the poll of possible entry points the sulci, as part of brain cortex where superficial blood vessels are naturally located. A limited set of trajectories is then computed and presented to the surgeon, satisfying an optimality criteria based on a cost function which considers the distance from critical brain areas and the whole trajectory length. The planner proved to be effective in defining rectilinear trajectories accounting for the safety constraints determined by the brain morphology. It also demonstrated a short computational time and good capability in segmenting gyri and sulci surfaces.

  7. Multivariate Cryptography Based on Clipped Hopfield Neural Network.

    Science.gov (United States)

    Wang, Jia; Cheng, Lee-Ming; Su, Tong

    2018-02-01

    Designing secure and efficient multivariate public key cryptosystems [multivariate cryptography (MVC)] to strengthen the security of RSA and ECC in conventional and quantum computational environment continues to be a challenging research in recent years. In this paper, we will describe multivariate public key cryptosystems based on extended Clipped Hopfield Neural Network (CHNN) and implement it using the MVC (CHNN-MVC) framework operated in space. The Diffie-Hellman key exchange algorithm is extended into the matrix field, which illustrates the feasibility of its new applications in both classic and postquantum cryptography. The efficiency and security of our proposed new public key cryptosystem CHNN-MVC are simulated and found to be NP-hard. The proposed algorithm will strengthen multivariate public key cryptosystems and allows hardware realization practicality.

  8. Treatment of Complex Fistula-in-Ano With a Nitinol Proctology Clip

    DEFF Research Database (Denmark)

    Nordholm-Carstensen, Andreas; Krarup, Peter-Martin; Hagen, Kikke

    2017-01-01

    BACKGROUND: The treatment of complex anocutaneous fistulas remains a major therapeutic challenge balancing the risk of incontinence against the chance of permanent closure. OBJECTIVE: The purpose of this study was to investigate the efficacy of a nitinol proctology clip for closure of complex ano...... with those of other noninvasive, sphincter-sparing techniques for high-complex anocutaneous fistulas, with no risk of incontinence. Predictive parameters for fistula healing using this technique remain uncertain. See Video Abstract at http://links.lww.com/DCR/A347....

  9. Robotic and artificial intelligence for keyhole neurosurgery: the ROBOCAST project, a multi-modal autonomous path planner.

    Science.gov (United States)

    De Momi, E; Ferrigno, G

    2010-01-01

    The robot and sensors integration for computer-assisted surgery and therapy (ROBOCAST) project (FP7-ICT-2007-215190) is co-funded by the European Union within the Seventh Framework Programme in the field of information and communication technologies. The ROBOCAST project focuses on robot- and artificial-intelligence-assisted keyhole neurosurgery (tumour biopsy and local drug delivery along straight or turning paths). The goal of this project is to assist surgeons with a robotic system controlled by an intelligent high-level controller (HLC) able to gather and integrate information from the surgeon, from diagnostic images, and from an array of on-field sensors. The HLC integrates pre-operative and intra-operative diagnostics data and measurements, intelligence augmentation, multiple-robot dexterity, and multiple sensory inputs in a closed-loop cooperating scheme including a smart interface for improved haptic immersion and integration. This paper, after the overall architecture description, focuses on the intelligent trajectory planner based on risk estimation and human criticism. The current status of development is reported, and first tests on the planner are shown by using a real image stack and risk descriptor phantom. The advantages of using a fuzzy risk description are given by the possibility of upgrading the knowledge on-field without the intervention of a knowledge engineer.

  10. Effects of Milrinone continuous intravenous infusion on global cerebral oxygenation and cerebral vasospasm after cerebral aneurysm surgical clipping

    Directory of Open Access Journals (Sweden)

    Mohamed A. Ghanem

    2014-01-01

    Conclusions: Milrinone improved significantly the global cerebral oxygenation and reduced the incidence of cerebral vasospasm during the dangerous period of cerebral spasm after cerebral aneurysm clipping.

  11. Morphological Changes in Blood Cells After Implantation of Titanium and Plastic Clips in the Neurocranium - Experimental Study on Dogs.

    Science.gov (United States)

    Katica, Muhamed; Celebicic, Mirza; Gradascevic, Nedzad; Obhodzas, Muamer; Suljić, Enra; Ocuz, Muhamed; Delibegovic, Samir

    2017-04-01

    Various studies confirm the biocompatibility and efficacy of clips for certain target tissues, but without any comparative analysis of hematological parameters. Therefore, we conducted a study to assess the possible association of the implantation of titanium and plastic clips in the neurocranium with possible morphological changes in the blood cells of experimental animals. As a control, the peripheral blood smears were taken before surgery from 12 adult dogs that were divided into two experimental groups. After placing titanium and plastic clips in the neurocranium, the peripheral blood of the first group was analyzed on the seventh postoperative day, while the peripheral blood of the second group was analyzed on the sixtieth day. By microscopy of the blood smears, the following parameters were analyzed: the presence of poikilocytosis of the red blood cells, degenerative changes in the leukocytes and leukogram. There were no statistically significant differences between the mean values of the groups. Monocytosis was detected (first group 22.83 % and second 16.30 %), as well as neutropenia (46.80 %, in the second group). Degenerative changes to neutrophils and the occurrence of atypical lymphocytes were observed in the second experimental group (60 th postoperative day). A mild adverse effect from the biomaterials present in the neurocranium of dogs was detected, affecting the majority of leukocytic cells. A chronic recurrent inflammatory process was caused by the presence of the plastic and titanium clips in the brain tissue. No adverse effect of biomaterials on erythrocytes in the neurocranium was detected in the dogs studied. Further studies are necessary to explain the occurrence of degenerative changes in the neutrophils and lymphocytes.

  12. Polymer Basics: Classroom Activities Manipulating Paper Clips to Introduce the Structures and Properties of Polymers

    Science.gov (United States)

    Umar, Yunusa

    2014-01-01

    A simple and effective hands-on classroom activity designed to illustrate basic polymer concepts is presented. In this activity, students build primary structures of homopolymers and different arrangements of monomers in copolymer using paper clips as monomers. The activity supports formation of a basic understanding of polymer structures,…

  13. Initial experience of percutaneous treatment of mitral regurgitation with MitraClip® therapy in Spain.

    Science.gov (United States)

    Carrasco-Chinchilla, Fernando; Arzamendi, Dabit; Romero, Miguel; Gimeno de Carlos, Federico; Alonso-Briales, Juan Horacio; Li, Chi-Hion; Mesa, Maria Dolores; Arnold, Roman; Serrador Frutos, Ana María; Pan, Manuel; Roig, Eulalia; Rodríguez-Bailón, Isabel; de la Fuente Galán, Luis; Hernández, José María; Serra, Antonio; Suárez de Lezo, José

    2014-12-01

    Symptomatic mitral regurgitation has an unfavorable prognosis unless treated by surgery. However, the European registry of valvular heart disease reports that 49% of patients with this condition do not undergo surgery. Percutaneous treatment of mitral regurgitation with MitraClip® has been proved a safe, efficient adjunct to medical treatment in patients with this profile. The objective of the present study is to describe initial experience of MitraClip® therapy in Spain. Retrospective observational study including all patients treated between November 2011 and July 2013 at the 4 Spanish hospitals recording the highest numbers of implantations. A total of 62 patients (77.4% men) were treated, mainly for restrictive functional mitral regurgitation (85.4%) of grade III (37%) or grade IV (63%), mean (standard deviation) ejection fraction 36% (14%), and New York Heart Association functional class III (37%) or IV (63%). Device implantation was successful in 98% of the patients. At 1 year, 81.2% had mitral regurgitation ≤ 2 and 90.9% were in New York Heart Association functional class ≤ II. One periprocedural death occurred (sepsis at 20 days post-implantation) and another 3 patients died during follow-up (mean, 9.1 months). Two patients needed a second implantation due to partial dehiscence of the first device and 2 others underwent heart transplantation. In Spain, MitraClip® therapy has principally been aimed at patients with functional mitral regurgitation, significant systolic ventricular dysfunction, and high surgical risk. It is considered a safe alternative treatment, which can reduce mitral regurgitation and improve functional capacity. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  14. α-Tubulin Tyrosination and CLIP-170 Phosphorylation Regulate the Initiation of Dynein-Driven Transport in Neurons

    Directory of Open Access Journals (Sweden)

    Jeffrey J. Nirschl

    2016-03-01

    Full Text Available Motor-cargo recruitment to microtubules is often the rate-limiting step of intracellular transport, and defects in this recruitment can cause neurodegenerative disease. Here, we use in vitro reconstitution assays with single-molecule resolution, live-cell transport assays in primary neurons, computational image analysis, and computer simulations to investigate the factors regulating retrograde transport initiation in the distal axon. We find that phosphorylation of the cytoskeletal-organelle linker protein CLIP-170 and post-translational modifications of the microtubule track combine to precisely control the initiation of retrograde transport. Computer simulations of organelle dynamics in the distal axon indicate that while CLIP-170 primarily regulates the time to microtubule encounter, the tyrosination state of the microtubule lattice regulates the likelihood of binding. These mechanisms interact to control transport initiation in the axon in a manner sensitive to the specialized cytoskeletal architecture of the neuron.

  15. Association between an aplastic basilar artery, unaccompanied by a primitive carotid-vertebrobasilar anastomosis, and multiple aneurysms on the dominant posterior communicating artery.

    Science.gov (United States)

    Behari, Sanjay; Krishna, Himanshu; Kumar, Marakani V Kiran; Sawlani, Vijay; Phadke, Rajendra V; Jain, Vijendra K

    2004-05-01

    Basilar artery (BA) aplasia when unaccompanied by a primitive carotid-vertebrobasilar anastomosis is exceedingly rare. The association of BA aplasia with two aneurysms on the dominant posterior communicating artery (PCoA) has not been previously reported. This 40-year-old man presented in a state of drowsiness and responded to simple commands only after being coaxed. He had complete left cranial third nerve palsy, right hemiparesis, and persisting signs of meningeal irritation. A computerized tomography (CT) scan revealed subarachnoid and intraventricular hemorrhage. An angiogram revealed BA aplasia. The right PCoA followed a sinuous course with multiple loops and provided the dominant supply to the posterior circulation. This vessel harbored two aneurysms, one at the origin of the PCoA from the internal carotid artery and the other at the looping segment just proximal to the brainstem. The left PCoA was extremely thin. The pterional transsylvian approach was used to clip the two aneurysms on the PCoA. The hemodynamic changes produced by the BA aplasia may have produced alterations in the cerebral vasculature leading to aneurysm formation and consequent subarachnoid hemorrhage.

  16. Trace elements in nail polish as a source of contamination of nail clippings when used in epidemiological studies

    International Nuclear Information System (INIS)

    Favaro, P.C.; Bode, P.; De Nadai Fernandes, E.A.

    2005-01-01

    Trace elements were determined in 27 brands of nail polish using INAA so as to estimate the impact of nail polish remainders when using (finger, toe) nail clippings as a bioindicator for epidemiological studies. Fe was found to be present up to almost 1.7% in one brand. No unambiguous correlation between trace elements and color was established, though transparent polish has the lowest trace element concentrations. An estimate of the maximum effect (no removal of the paint) indicates that over-estimates of some trace element levels in nail with more than 200.000% may occur. If nail clippings will be used to study trace elements, very high demands have to be set to the efficiency and selectivity of the cleaning procedure. (author)

  17. Coiling and clipping of middle cerebral artery aneurysms: a systematic review on clinical and imaging outcome

    NARCIS (Netherlands)

    Zijlstra, Ijsbrand A.; Verbaan, Dagmar; Majoie, Charles B.; Vandertop, Peter; van den Berg, Rene

    2016-01-01

    There is an ongoing debate on the preferred treatment of middle cerebral artery (MCA) aneurysms. The purpose of this study was to assess the clinical and imaging outcomes comparing conventional coiling and clipping of unruptured and ruptured MCA aneurysms. We searched the electronic databases

  18. Cerebral activation associated with sexual arousal in response to a pornographic clip: A 15O-H2O PET study in heterosexual men.

    Science.gov (United States)

    Bocher, M; Chisin, R; Parag, Y; Freedman, N; Meir Weil, Y; Lester, H; Mishani, E; Bonne, O

    2001-07-01

    This study attempted to use PET and 15O-H2O to measure changes in regional cerebral blood flow (rCBF) during sexual arousal evoked in 10 young heterosexual males while they watched a pornographic video clip, featuring heterosexual intercourse. This condition was compared with other mental setups evoked by noisy, nature, and talkshow audiovisual clips. Immediately after each clip, the participants answered three questions pertaining to what extent they thought about sex, felt aroused, and sensed an erection. They scored their answers using a 1 to 10 scale. SPM was used for data analysis. Sexual arousal was mainly associated with activation of bilateral, predominantly right, inferoposterior extrastriate cortices, of the right inferolateral prefrontal cortex and of the midbrain. The significance of those findings is discussed in the light of current theories concerning selective attention, "mind reading" and mirroring, reinforcement of pleasurable stimuli, and penile erection.

  19. Exploring the Use of Video-Clips for Motivation Building in a Secondary School EFL Setting

    Science.gov (United States)

    Park, Yujong; Jung, Eunsu

    2016-01-01

    By employing an action research framework, this study evaluated the effectiveness of a video-based curriculum in motivating EFL learners to learn English. Fifteen Korean EFL students at the secondary school context participated in an 8-week English program, which employed video clips including TED talk replays, sitcoms, TV news reports and movies…

  20. Acute outcomes after MitraClip therapy in highly aged patients: results from the German TRAnscatheter Mitral valve Interventions (TRAMI) Registry.

    Science.gov (United States)

    Schillinger, Wolfgang; Hünlich, Mark; Baldus, Stephan; Ouarrak, Taoufik; Boekstegers, Peter; Hink, Ulrich; Butter, Christian; Bekeredjian, Raffi; Plicht, Björn; Sievert, Horst; Schofer, Joachim; Senges, Jochen; Meinertz, Thomas; Hasenfuß, Gerd

    2013-05-20

    The influence of age on baseline demographics and outcomes of patients selected for MitraClip has not been previously investigated. Baseline demographics and acute outcomes in 1,064 patients from the German TRAMI registry were stratified by age (525 patients ≥76 years and 539 patients 50% (40.1% vs. 21.8%, p<0.0001) and degenerative mitral regurgitation (DMR, 35.3% vs. 25.6%, p<0.01). Age was the most frequent reason for non-surgical treatment in the elderly (69.4% vs. 36.1%, p<0.0001). The intrahospital MACCE (death, myocardial infarction, stroke) was low in both groups (3.5% vs. 3.4%, p=0.93) and the proportion of non-severe mitral regurgitation at discharge was similar (95.8% vs. 96.4%, p=0.73). A logistic regression model did not reveal any significant impact of age on acute efficacy and safety of MitraClip therapy. In both groups, the majority of patients were discharged home (81.8% vs. 86.2%, p=0.06). Elderly and younger patients have similar benefits from MitraClip therapy. Age was the most frequent cause for denying surgery in elderly patients.

  1. COMPOSITIONAL AND CONTENT-RELATED PARTICULARITIES OF POLITICAL MEDIA TEXTS (THROUGH THE EXAMPLE OF THE TEXTS OF POLITICAL VIDEO CLIPS ISSUED BY THE CANDIDATES FOR PRESIDENCY IN FRANCE IN 2017

    Directory of Open Access Journals (Sweden)

    Dmitrieva, A.V.

    2017-09-01

    Full Text Available The article examines the texts of political advertising video clips issued by the candidates for presidency in France during the campaign before the first round of elections in 2017. The mentioned examples of media texts are analysed from the compositional point of view as well as from that of the content particularities which are directly connected to the text structure. In general, the majority of the studied clips have a similar structure and consist of three parts: introduction, main part and conclusion. However, as a result of the research, a range of advantages marking well-structured videos was revealed. These include: addressing the voters and stating the speech topic clearly at the beginning of the clip, a relevant attention-grabbing opening phrase, consistency and clarity of the information presentation, appropriate use of additional video plots, conclusion at the end of the clip.

  2. Improved results of the vacuum assisted closure and Nitinol clips sternal closure after postoperative deep sternal wound infection.

    Science.gov (United States)

    Tocco, Maria Pia; Costantino, Alberto; Ballardini, Milva; D'Andrea, Claudio; Masala, Marcello; Merico, Eusebio; Mosillo, Luigi; Sordini, Paolo

    2009-05-01

    Postoperative deep sternal wound infection is a severe complication of cardiac surgery, with a high mortality rate and a high morbidity rate. The objective of this prospective study is to report our experience with the vacuum assisted closure (VAC) system for the management of deep wound infection. We also devised an innovative closure technique post VAC therapy using thermo reactive clips. The advantage of this technique is that the posterior face of the sternum does not have to be separated from the mediastinal structures thus minimising the risk of damage. From October 2006 to October 2008, we prospectively evaluated 21 patients affected by mediastinitis after sternotomy. Nineteen patients had sternotomy for coronary artery bypass grafting (CABG), one patient for aortic valve replacement (AVR) and another one for ascending aortic replacement (AAR). All patients were treated with the VAC system at the time of infection diagnosis. When the wound tissue appeared viable and the microbiological cultures were negative, the chest was closed using the most suitable procedure for the patient in question; nine patients were closed using pectoralis flaps, nine patients using Nitinol clips, one patient with a combined technique (use of Nitinol clips and muscle flap), one patient with a direct wound closure and another patient, who needed AAR with a homograft performed in another institution, was closed using sternal wires. We had no mortality; wound healing was successfully achieved in all patients. In more than 50% of the patients, the VAC therapy allowed direct sternal resynthesis. The average duration of the vacuum therapy was 26 days (range 14-37 days). VAC is a safe and effective option in the treatment of post-sternotomy mediastinitis, with excellent survival and immediate improvement of local wound conditions; furthermore, the use of Nitinol clips after VAC therapy demonstrated to be a safe and non-invasive option for sternal resynthesis. After VAC therapy, a

  3. Salvage of a failed open gastrocutaneous fistula repair with an endoscopic over-the-scope clip

    Directory of Open Access Journals (Sweden)

    Joshua Jaramillo

    2016-05-01

    Full Text Available Once enteral access via gastrostomy tube (G-tube is no longer indicated, the tube is typically removed in clinic with a high probability of spontaneous closure. When spontaneous closure is not achieved, the formation of a gastrocutaneous fistula (GCF is possible. The incidence of GCF is directly related with the length of time the tube has been placed. When conservative management fails, surgical intervention is the standard treatment. Endoscopic techniques have been described for primary closure of GCF in adults including banding and cauterizing of the fistula tract with placement of a standard endoscopic clip. Over-the-scope clips (OTSC have recently been reported in primary GCF closure in children (Wright et al., 2015. In patients with skin irritation surrounding a GCF making surgical repair difficult, endoscopic OTSC closure provides particular benefit. It is our belief that this is the first case report of endoscopically salvaging a leak from a failed open GCF repair.

  4. Effects of Mitral Annulus Remodeling Following MitraClip Procedure on Reduction of Functional Mitral Regurgitation.

    Science.gov (United States)

    Hidalgo, Francisco; Mesa, Dolores; Ruiz, Martín; Delgado, Mónica; Rodríguez, Sara; Pardo, Laura; Pan, Manuel; López, Amador; Romero, Miguel A; Suárez de Lezo, José

    2016-11-01

    The percutaneous mitral valve repair procedure (MitraClip) appears to reduce mitral annulus diameter in patients with functional mitral regurgitation, but the relationship between this and regurgitation severity has not been demonstrated. The aim of this study was to determine the effect of mitral annulus remodeling on the reduction of mitral regurgitation in patients with functional etiology. The study included all patients with functional mitral regurgitation treated with MitraClip at our hospital until January 2015. Echocardiogram (iE33 model, Philips) was performed in all patients immediately after device positioning. Changes in the mitral annulus correlated with mitral regurgitation severity, as assessed using the effective regurgitant orifice area. The study included 23 patients (age, 65±14 years; 74% men; left ventricular ejection fraction, 31%±13%; systolic pulmonary artery pressure, 47±10 mmHg). After the procedure, the regurgitant orifice area decreased by 0.30 cm 2 ±0.04 cm 2 (P<.0005), from a baseline of 0.49 cm 2 ±0.09 cm 2 . Anteroposterior diameter decreased by 3.14 mm±1.01 mm (P<.0005) from a baseline of 28.27 mm±4.9 mm, with no changes in the intercommissural diameter (0.50 mm±0.91 mm vs 40.68 mm±4.7 mm; P=.26). A significant association was seen between anteroposterior diameter reduction and regurgitant orifice area reduction (r=.49; P=.020). In patients with functional mitral regurgitation, the MitraClip device produces an immediate reduction in the anteroposterior diameter. This remodeling may be related to the reduction in mitral regurgitation. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  5. A meta-analysis of MitraClip system versus surgery for treatment of severe mitral regurgitation

    DEFF Research Database (Denmark)

    Wan, Benjamin; Rahnavardi, Mohammad; Tian, David H

    2013-01-01

    to the surgical group (17.2% vs. 0.4%; P.... The purpose of this meta-analysis is to compare the safety, clinical efficacy, and survival outcomes of MitraClip implantation with surgical correction of severe MR. METHODS: Six electronic databases were searched for original published studies from January 2000 to August 2013. Two reviewers independently...

  6. Ovarian cryopreservation after laparoscopic ovariectomy using the Endo-GIA stapling device and LAPRO-clip absorbable ligating clip in a woman: a case report

    Directory of Open Access Journals (Sweden)

    Messner Alexandra

    2011-02-01

    Full Text Available Abstract Introduction Several options are available for preserving fertility before cytotoxic treatment, including ovarian tissue cryopreservation. Most reported surgical techniques include electrocoagulation. Our hypothesis is that avoidance of electrocoagulation may decrease ovarian cortex injury during cryopreservation procedures. Case presentation We report a laparoscopic technique of whole-ovary removal without coagulation using Endo-GIA forceps and clips. Laparoscopic ovariectomy was performed for cryopreservation in a 37-year-old Caucasian woman with breast cancer and for whom chemotherapy was planned. The procedure was completed quickly and without complication. This Endo-GIA procedure was of short duration with a short period of ischemia before freezing. Conclusion Laparoscopic ovariectomy using the Endo-GIA stapling device procedure without coagulation may diminish ovary injury before ovarian cryopreservation.

  7. Ovarian cryopreservation after laparoscopic ovariectomy using the Endo-GIA stapling device and LAPRO-clip absorbable ligating clip in a woman: a case report

    Science.gov (United States)

    2011-01-01

    Introduction Several options are available for preserving fertility before cytotoxic treatment, including ovarian tissue cryopreservation. Most reported surgical techniques include electrocoagulation. Our hypothesis is that avoidance of electrocoagulation may decrease ovarian cortex injury during cryopreservation procedures. Case presentation We report a laparoscopic technique of whole-ovary removal without coagulation using Endo-GIA forceps and clips. Laparoscopic ovariectomy was performed for cryopreservation in a 37-year-old Caucasian woman with breast cancer and for whom chemotherapy was planned. The procedure was completed quickly and without complication. This Endo-GIA procedure was of short duration with a short period of ischemia before freezing. Conclusion Laparoscopic ovariectomy using the Endo-GIA stapling device procedure without coagulation may diminish ovary injury before ovarian cryopreservation. PMID:21291518

  8. Single loop-and-clips technique (KING closure) for gastrotomy closure after transgastric ovariectomy: a survival experiment

    Czech Academy of Sciences Publication Activity Database

    Ryska, O.; Martinek, J.; Filípková, T.; Doležel, R.; Juhásová, Jana; Motlík, Jan; Zavoral, M.; Ryska, M.

    2012-01-01

    Roč. 7, č. 4 (2012), s. 233-239 ISSN 1895-4588 R&D Projects: GA MZd NS9994 Institutional research plan: CEZ:AV0Z50450515 Keywords : natural orifice transluminal endoscopic surgery * gastric closure * clips * endoloop Subject RIV: FJ - Surgery incl. Transplants Impact factor: 0.757, year: 2012

  9. Closure of leak at the tip of the “J” after ileal pouch-anal anastomosis using a novel over-the-scope clipping system

    Directory of Open Access Journals (Sweden)

    Lei Lian

    2014-04-01

    Full Text Available Objective: leaks from the body or the tip of the J-pouch can occur after restorative proctocolecotmy. Although it may follow an indolent clinical course, it often requires surgical repair or pouch revision. Here we describe a novel endoscopic approach to close the leak at the tip of the J pouch. Design: pouchoscopy was performed under sedation and endoscopic over-the-scope clipping system was used for the management of a leak from the tip of a J-pouch. Results: under sedation, a pouchoscopy was performed and the deep tip of “J” leak was detected with a guidewire, along with water-contrasted pouchogram. The contained cavity from the leak was cleaned with hydrogen peroxide and 50% dextrose. Debridement of the epithelialized mouth of the leak was performed with an endoscopic cytology brush. Then endoscopic over-the-scope clipping system was used and the leak defect was completely closed. There was no bleeding or perforation. The entire procedure took 25 min. The patient continued to do well and reported resolution of the low back pain symptom. Conclusion: we reported the first case in the literature that a leak from the tip of a J-pouch was endoscopically occluded using a novel over-the-scope clipping system. Resumo: Objetive: vazamentos do corpo da bolsa e da extremidade da bolsa ileal em J podem ocorrer após proctocolectomia restauradora. Embora possam apresentar um curso clínico indolente, muitas vezes requerem procedimentos abdominais. Desenho: endoscopia da bolsa ileal foi realizada sob sedação e clipagem endoscópica usando o sistema “over-the-scope” foi utilizada para fechar um vazamento na extremidade da bolsa ileal em “J”. Resultados: sob sedação, uma endoscopia de bolsa ileal foi realizada e a extremidade profunda do vazamento da bolsa ileal em “J” foi detectada com um fio-guia. A cavidade que continha o vazamento foi limpa com peróxido de hidrogênio e 50% de dextrose. Desbridamento da borda epitelizada do

  10. A memory efficient user interface for CLIPS micro-computer applications

    Science.gov (United States)

    Sterle, Mark E.; Mayer, Richard J.; Jordan, Janice A.; Brodale, Howard N.; Lin, Min-Jin

    1990-01-01

    The goal of the Integrated Southern Pine Beetle Expert System (ISPBEX) is to provide expert level knowledge concerning treatment advice that is convenient and easy to use for Forest Service personnel. ISPBEX was developed in CLIPS and delivered on an IBM PC AT class micro-computer, operating with an MS/DOS operating system. This restricted the size of the run time system to 640K. In order to provide a robust expert system, with on-line explanation, help, and alternative actions menus, as well as features that allow the user to back up or execute 'what if' scenarios, a memory efficient menuing system was developed to interface with the CLIPS programs. By robust, we mean an expert system that (1) is user friendly, (2) provides reasonable solutions for a wide variety of domain specific problems, (3) explains why some solutions were suggested but others were not, and (4) provides technical information relating to the problem solution. Several advantages were gained by using this type of user interface (UI). First, by storing the menus on the hard disk (instead of main memory) during program execution, a more robust system could be implemented. Second, since the menus were built rapidly, development time was reduced. Third, the user may try a new scenario by backing up to any of the input screens and revising segments of the original input without having to retype all the information. And fourth, asserting facts from the menus provided for a dynamic and flexible fact base. This UI technology has been applied successfully in expert systems applications in forest management, agriculture, and manufacturing. This paper discusses the architecture of the UI system, human factors considerations, and the menu syntax design.

  11. Experimental evaluation of fluorescent (alizarin red S and calcein) and clip-tag markers for stock assessment of ark shell, Anadara broughtonii

    Science.gov (United States)

    Zhou, Shanshan; Zhang, Xiumei; Li, Wentao; Li, Long; Cai, Xingyuan

    2017-03-01

    Release programs to enhance stocks of ark shell ( Anadara broughtonii) have been undertaken in a number of Asian countries, but their effectiveness has rarely been investigated owing to a lack of marking methods. The quality and longevity of fluorescent markers, alizarin red S (ARS) and calcein (CAL) (200 and 300 mg/L), as well as clip tags, were tested on juvenile A. broughtonii. No significant differences in survival or shell growth were observed in juveniles stained with either of the two fluorochromes after a 160-day culture period, but the retention rate was 100% after 1 year. Fluorescent marks (≥grade 3) were observable microscopically in juveniles stained with the two fluorochromes, and some fluorescent marks (≥grade 4) were visible with the naked eye after 1 year. ARS-marked shells were brighter than those marked with CAL, and shells marked with 300 mg/L of the fluorochromes were easier to detect than those marked with 200 mg/L. Clip tags were incorporated into the shell as the bivalve grew, and the retention rate was 64.25% after 160 days. Significant differences in survival (at 30 days), shell length (at 60, 90, 120, and 160 days), and wet weight (at 90, 120, and 160 days) were observed between the clip-tagged and control groups (all P< 0.05), indicating that the tags may have passive effects on the ark shell. The results suggest that both ARS and CAL are suitable to mark A. broughtonii for large-scale restocking programs, and that optimal marking quality was achieved with 300 mg/L ARS. Lighter and smaller clip tags need to be developed to reduce injury and increase survival rate of clams.

  12. Pilot study of a heptavalent vaccine-keyhole limpet hemocyanin conjugate plus QS21 in patients with epithelial ovarian, fallopian tube, or peritoneal cancer

    DEFF Research Database (Denmark)

    Sabbatini, Paul J; Ragupathi, Govind; Hood, Chandra

    2007-01-01

    PURPOSE: To characterize the safety and immunogenicity of a heptavalent antigen-keyhole limpet hemocyanin (KLH) plus QS21 vaccine construct in patients with epithelial ovarian, fallopian tube, or peritoneal cancer in second or greater complete clinical remission. EXPERIMENTAL DESIGN: Eleven......). RESULTS: Eleven patients were included in the safety analysis; 9 of 11 patients remained on study for at least 2 weeks past fourth vaccination and were included in the immunologic analysis (two withdrew, disease progression). The vaccine was well tolerated. Self-limited and mild fatigue (maximum grade 2...... patients in this pilot trial received a heptavalent vaccine s.c. containing GM2 (10 microg), Globo-H (10 microg), Lewis Y (10 microg), Tn(c) (3 microg), STn(c) (3 microg), TF(c) (3 microg), and Tn-MUC1 (3 microg) individually conjugated to KLH and mixed with adjuvant QS21(100 microg). Vaccinations were...

  13. Delayed recovery of adipsic diabetes insipidus (ADI) caused by elective clipping of anterior communicating artery and left middle cerebral artery aneurysms.

    Science.gov (United States)

    Tan, Jeffrey; Ndoro, Samuel; Okafo, Uchenna; Garrahy, Aoife; Agha, Amar; Rawluk, Danny

    2016-12-16

    Adipsic diabetes insipidus (ADI) is an extremely rare complication following microsurgical clipping of anterior communicating artery aneurysm (ACoA) and left middle cerebral artery (MCA) aneurysm. It poses a significant challenge to manage due to an absent thirst response and the co-existence of cognitive impairment in our patient. Recovery from adipsic DI has hitherto been reported only once. A 52-year-old man with previous history of clipping of left posterior communicating artery aneurysm 20 years prior underwent microsurgical clipping of ACoA and left MCA aneurysms without any intraoperative complications. Shortly after surgery, he developed clear features of ADI with adipsic severe hypernatraemia and hypotonic polyuria, which was associated with cognitive impairment that was confirmed with biochemical investigations and cognitive assessments. He was treated with DDAVP along with a strict intake of oral fluids at scheduled times to maintain eunatremia. Repeat assessment at six months showed recovery of thirst and a normal water deprivation test. Management of ADI with cognitive impairment is complex and requires a multidisciplinary approach. Recovery from ADI is very rare, and this is only the second report of recovery in this particular clinical setting.

  14. Long-term clinical and prosthetic outcomes of soft liner and clip attachments for bar/implant overdentures: a randomised controlled clinical trial.

    Science.gov (United States)

    ELsyad, M A; Shaheen, N H; Ashmawy, T M

    2017-06-01

    Long-term clinical and prosthetic outcomes of soft liner attachments for bar/implant overdentures were not sufficiently investigated. The aim of this trial was to evaluate clinical and prosthetic outcomes of resilient liner and clip attachments for bar/implant-retained mandibular overdenture after 7 years. Thirty edentulous male participants received two implants in the canine areas of the mandible. Three months later, implants were splinted with a resilient bar. Mandibular overdentures were connected to the bars with either clip (CR group, n = 15) or resilient liner (RR group, n = 15) attachments. Plaque index (PI), gingival index (GI), probing depth (PD), vertical bone loss (VBL), horizontal bone loss (HBLO) and prosthetic complications (PCs) were evaluated at denture delivery (T0), 6 (T 6m ), 12 (T1), 24 (T2), 36 (T3), 48 (T4), 60 (T5), 72 (T6) and 84 (T7) months after insertion. PI and GI increased significantly with time for CR and decreased significantly for RR (P overdentures than clip attachments in terms of peri-implant tissue health and prosthetic complications after 7 years. © 2017 John Wiley & Sons Ltd.

  15. Integration of object-oriented knowledge representation with the CLIPS rule based system

    Science.gov (United States)

    Logie, David S.; Kamil, Hasan

    1990-01-01

    The paper describes a portion of the work aimed at developing an integrated, knowledge based environment for the development of engineering-oriented applications. An Object Representation Language (ORL) was implemented in C++ which is used to build and modify an object-oriented knowledge base. The ORL was designed in such a way so as to be easily integrated with other representation schemes that could effectively reason with the object base. Specifically, the integration of the ORL with the rule based system C Language Production Systems (CLIPS), developed at the NASA Johnson Space Center, will be discussed. The object-oriented knowledge representation provides a natural means of representing problem data as a collection of related objects. Objects are comprised of descriptive properties and interrelationships. The object-oriented model promotes efficient handling of the problem data by allowing knowledge to be encapsulated in objects. Data is inherited through an object network via the relationship links. Together, the two schemes complement each other in that the object-oriented approach efficiently handles problem data while the rule based knowledge is used to simulate the reasoning process. Alone, the object based knowledge is little more than an object-oriented data storage scheme; however, the CLIPS inference engine adds the mechanism to directly and automatically reason with that knowledge. In this hybrid scheme, the expert system dynamically queries for data and can modify the object base with complete access to all the functionality of the ORL from rules.

  16. Right ventricular pressure elevated in one-kidney, one clip Goldblatt hypertensive rats.

    Science.gov (United States)

    Ketabchi, Farzaneh; Bajoovand, Shirin; Adlband, Mojtaba; Naseh, Maryam; Nekooeian, Ali A; Mashghoolozekr, Elaheh

    2017-01-01

    Both renal and respiratory diseases are common with high mortality rate around the world. This study was the first to compare effects of two kidneys, one clip (2K1C) and one-kidney, one clip (1K1C) Goldblatt hypertension on right ventricular pressure during normal condition and mechanical ventilation with hypoxia gas. Male Sprague-Dawley rats were subjected to control, 2K1C, or 1K1C groups. Twenty-eight days after the first surgery, animals were anesthetized, and femoral artery and vein, and right ventricle cannulated. Systemic arterial pressure and right ventricular systolic pressures (RVSP) were recorded during ventilation the animals with normoxic or hypoxic gas. RVSP in the 1K1C group was significantly more than the control and 2K1C groups during baseline conditions and ventilation the animals with hypoxic gas. Administration of antioxidant Trolox increased RVSP in the 1K1C and control groups compared with their baselines. Furthermore, there was no alteration in RVSP during hypoxia in the presence of Trolox. This study indicated that RVSP only increased after 28 days induction of 1K1C but not 2K1C model. In addition, it seems that the response to hypoxic gas and antioxidants in 1K1C is more than 2K1C. These data also suggest that effects of 1K1C may partially be related to reactive oxygen species (ROS) pathways.

  17. Multislice CT angiography in the selection of patients with ruptured intracranial aneurysms suitable for clipping or coiling

    NARCIS (Netherlands)

    Westerlaan, H. E.; Gravendeel, J.; Fiore, D.; Metzemaekers, J. D. M.; Groen, R. J. M.; Mooij, J. J. A.; Oudkerk, M.

    2007-01-01

    Introduction We sought to establish whether CT angiography (CTA) can be applied to the planning and performance of clipping or coiling in ruptured intracranial aneurysms without recourse to intraarterial digital subtraction angiography (IA-DSA). Methods Over the period April 2003 to January 2006 in

  18. Combined Interhemispheric and Transsylvian Approach for Resection of Craniopharyngioma.

    Science.gov (United States)

    Inoue, Tomohiro; Ono, Hideaki; Tamura, Akira; Saito, Isamu

    2018-04-01

    We present a 37-year-old male case of cystic suprasellar huge craniopharyngioma, who presented with significant memory disturbance due to obstructive hydrocephalus. Combined interhemispheric and pterional approach was chosen to resect huge suprasellar tumor. Interhemispheric trans-lamina terminalis approach was quite effective to resect third ventricular tumor, while pterional approach was useful to dissect tumor out of basilar perforators and stalk. The link to the video can be found at: https://youtu.be/BoYIPa96kdo .

  19. Dynamic-range reduction by peak clipping or compression and its effects on phoneme perception in hearing-impaired listeners

    NARCIS (Netherlands)

    Dreschler, W. A.

    1988-01-01

    In this study, differences between dynamic-range reduction by peak clipping and single-channel compression for phoneme perception through conventional hearing aids have been investigated. The results from 16 hearing-impaired listeners show that compression limiting yields significantly better

  20. Interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation

    International Nuclear Information System (INIS)

    Guo, Bing; Li, Jianbin; Wang, Wei; Xu, Min; Shao, Qian; Zhang, Yingjie; Liang, Chaoqian; Guo, Yanluan

    2015-01-01

    To explore the interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on the four-dimensional computed tomography (4DCT) scan for external-beam partial breast irradiation (EB-PBI) during free breathing. Patients with a seroma clarity score (SCS) 3 ~ 5 and ≥5 surgical clips in the lumpectomy cavity after breast-conserving surgery who were recruited for EB-PBI underwent 4DCT simulation. Based on the ten sets of 4DCT images acquired, the tumour bed formed using the clips, the seroma, and both the clips and seroma (defined as TB C , TB S and TB C+S , respectively) were delineated by five radiation oncologists using specific guidelines. The following parameters were calculated to analyse interobserver variability: volume of the tumour bed (TB C , TB S , TB C+S ), coefficient of variation (COV C , COV S , COV C+S ), and matching degree (MD C , MD S , MD C+S ). The interobserver variability for TB C and TB C+S and for COV C and COV C+S were statistically significant (p = 0.021, 0.008, 0.002, 0.015). No significant difference was observed for TB S and COV S (p = 0.867, 0.061). Significant differences in interobserver variability were observed for MD C vs MD S , MD C vs MD C+S , MD S vs MD C+S (p = 0.000, 0.032, 0.008), the interobserver variability of MD S was smaller than that of MD C and MD C+S (MD S > MD C+S > MD C ). When the SCS was 3 ~ 5 points and the number of surgical clips was ≥5, interobserver variability was minimal for the delineation of the tumour bed based on seroma

  1. Oral antibiotics enhance antibody responses to keyhole limpet hemocyanin in orally but not muscularly immunized chickens.

    Science.gov (United States)

    Murai, Atsushi; Kitahara, Kazuki; Okumura, Shouta; Kobayashi, Misato; Horio, Fumihiko

    2016-02-01

    Recent studies have emphasized the crucial role of gut microbiota in triggering and modulating immune response. We aimed to determine whether the modification of gut microbiota by oral co-administration of two antibiotics, ampicillin and neomycin, would lead to changes in the antibody response to antigens in chickens. Neonatal chickens were given or not given ampicillin and neomycin (0.25 and 0.5 g/L, respectively) in drinking water. At 2 weeks of age, the chicks were muscularly or orally immunized with antigenic keyhole limpet hemocyanin (KLH), and then serum anti-KLH antibody levels were examined by ELISA. In orally immunized chicks, oral antibiotics treatment enhanced antibody responses (IgM, IgA, IgY) by 2-3-fold compared with the antibiotics-free control, while the antibiotics did not enhance antibody responses in the muscularly immunized chicks. Concomitant with their enhancement of antibody responses, the oral antibiotics also lowered the Lactobacillus species in feces. Low doses of antibiotics (10-fold and 100-fold lower than the initial trial), which failed to change the fecal Lactobacillus population, did not modify any antibody responses when chicks were orally immunized with KLH. In conclusion, oral antibiotics treatment enhanced the antibody response to orally exposed antigens in chickens. This enhancement of antibody response was associated with a modification of the fecal Lactobacillus content, suggesting a possible link between gut microbiota and antibody response in chickens. © 2015 Japanese Society of Animal Science.

  2. Dual Selectivity Expressed in [2+2+1] Dynamic Clipping of Unsymmetrical [2]Catenanes

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yi

    2010-06-11

    A {pi}-templated dynamic [2+2+1] clipping protocol is established for the synthesis of [2]catenanes from two parts dialdehyde, two parts diamine and one part tetracationic cyclophane. It is further diversified for the selective formation of an unsymmetrical [2]catenane showing great translational selectivity by employing two different dialdehydes in a one-pot reaction. The dual selectivity and the dynamic nature are verified by {sup 1}H NMR spectroscopy, X-ray single crystal structural studies and exchange experiments.

  3. Estudo da Técnica Tig Keyhole por Meio do Análise Comparativo entre Duas Tochas de Alta Produtividade na União de Chapas de Aço Carbono de Meia Espessura

    OpenAIRE

    Olivares, Erick Alejandro González; Silva, Régis Henrique Gonçalves e; Dutra, Jair Carlos

    2015-01-01

    Resumo Na bibliografia de referência comum, a soldagem por meio da técnica Keyhole sempre foi associada a processos de soldagem com uma alta concentração de energia, como o processo Laser ou o processo Plasma. Novos avanços em tochas TIG estão mudando a forma em como o processo de soldagem TIG deveria ser considerado. Um exemplo desses novos avanços é a tocha comercialmente conhecida como Infocus, que segundo seus fabricantes a principal característica da tocha é a capacidade de concentração ...

  4. International Subarachnoid Aneurysm Trial 2009 : Endovascular Coiling of Ruptured Intracranial Aneurysms Has No Significant Advantage Over Neurosurgical Clipping

    NARCIS (Netherlands)

    Bakker, Nicolaas A.; Metzemaekers, Jan D. M.; Groen, Rob J. M.; Mooij, Jan Jakob A.; Van Dijk, J. Marc C.

    In the May 2009 issue of The Lancet Neurology, the 5-year follow-up results of the International Subarachnoid Aneurysm Trial (ISAT) were published. The authors concluded that, although the significant difference between coiling and neurosurgical clipping of ruptured intracranial aneurysms in terms

  5. Differential precocious sexual development of Proctoeces lintoni (Digenea: Fellodistomidae) in three sympatric species of keyhole limpets Fissurella spp. may affect transmission to the final host.

    Science.gov (United States)

    Balboa, L; George-Nascimento, M; Ojeda, F P

    2001-10-01

    The prevalence, abundance, and developmental status of the digenetic trematode Proctoeces lintoni Siddiqui et Cable 1960 were compared in 3 species of keyhole limpets Fissurella. A total of 197 limpets was collected at Caleta Chome, south-central Chile. Fissurella picta and F. costata had the highest prevalence of infection, whereas F. picta showed the greatest abundance of parasites, which increased with host shell length. However, the frequency of P. lintoni specimens with eggs in the uterus was greatest in F. costata. These results suggest that an increased rate of development of a parasite in the intermediate host may shorten the residence time necessary for maturation in the final host. Thus, faster development of the parasite in F. costata suggests the possibility that the parasites transmitted through this host species have shorter maturation times in clingfishes than individuals transmitted via other limpet species.

  6. Papaverine is a confounding factor in neurological assessment after cerebral aneurysm clipping: Report of three cases and review of the literature

    Directory of Open Access Journals (Sweden)

    Veena Sheshadri

    2016-01-01

    Full Text Available Intracisternal papaverine instillation is being used across many centers after cerebral aneurysm clipping to prevent and treat cerebral vasospasm. Pupillary dilatation secondary to papaverine can interfere with the neurological assessment postoperatively. This report describes pupillary changes in three patients following the papaverine application after craniotomy and aneurysm clipping, with one patient developing contralateral pupillary dilatation and the other two having bilateral pupillary dilatation. The pupillary changes resolved over 30 min to 4 h postoperatively. We conclude that pupillary changes following papaverine instillation could be a transient phenomenon and should not be considered ominous in absence of new onset neurological deficits. Intraoperative somatosensory evoked potential monitoring also helped in postoperative decision making in all our cases.

  7. Left cardiac chambers reverse remodeling after percutaneous mitral valve repair with the MitraClip system.

    Science.gov (United States)

    Scandura, Salvatore; Ussia, Gian Paolo; Capranzano, Piera; Caggegi, Anna; Sarkar, Kunal; Cammalleri, Valeria; Mangiafico, Sarah; Chiarandà, Marta; Immè, Sebastiano; Di Pasqua, Fabio; Pistritto, Anna Maria; Millan, Giovanni; Tamburino, Corrado

    2012-10-01

    Successful mitral valve surgical repair, decreasing volume overload, has been shown to provide reverse left ventricular (LV) and/or left atrial remodeling in most patients. Percutaneous mitral valve repair with the MitraClip system (Abbott, Abbott Park, IL) has been associated with favorable clinical outcomes in patients with mitral regurgitation at high risk of surgery. However, specific data on left cardiac chambers reverse remodeling after such procedures are limited. This was a prospective observational study of consecutive patients at high risk of surgery, with moderate-to-severe or severe mitral regurgitation undergoing MitraClip system implantation. Follow-up echocardiography was performed at 6 months. The evaluated parameters were the LV end-diastolic and end-systolic volume indexes, LV sphericity index, LV ejection fraction, and left atrial volume index. Reverse LV remodeling was defined as a decrease of 10% in the LV end-diastolic volume index. The study population included 44 patients: 14 with degenerative and 30 with functional mitral regurgitation. At 6 months of follow-up, significant reductions in the median and interquartile range of the sphericity index (from 0.57 [interquartile range 0.54-0.62] to 0.54 [interquartile range 0.50-0.58]; P interquartile range 63.0-102.2] to 60.7 mL/m(2) [50.8-84.4]; P interquartile range 28.2-70.5] to 28.9 mL/m(2) [interquartile range 22.2-55.8]; P interquartile range 30.0-55.0%] to 46.0% [interquartile range 35.0-58.0%]; P < .001) from baseline to 6 months. Minor differences in the left atrial volume index were observed. Reverse remodeling, according to the specified definition, was observed in 77.3% of the patients. The present study reports positive LV reshape effects after mitral valve repair with the MitraClip system, showing significant improvements in LV size and function. Copyright © 2012 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

  8. Olfactory groove meningioma: report of 99 cases surgically treated at the Catholic University School of Medicine, Rome.

    Science.gov (United States)

    Pallini, Roberto; Fernandez, Eduardo; Lauretti, Liverana; Doglietto, Francesco; D'Alessandris, Quintino Giorgio; Montano, Nicola; Capo, Gabriele; Meglio, Mario; Maira, Giulio

    2015-02-01

    We reviewed our series of olfactory groove meningiomas (OGMs) with the aim to relate the surgical approach with outcome and to define clinical and pathologic predictors of prognosis. Ninety-nine patients who underwent 113 craniotomies at our Institution between 1984 and 2010 were entered this study. The relationship between surgical approach (bifrontal, fronto-orbito-basal, and pterional) and either tumor diameter, extent of tumor resection, complication rate, need of reoperation, and Karnofsky Performance Status (KPS) was analyzed. The impact of age (≤ 70 vs. > 70 years), sex, tumor diameter (OGMs published to date, the bifrontal approach was associated with a greater risk of life-threatening complications compared with the lateral pterional and fronto-orbito-basal approaches. The fronto-orbito-basal approach provided greater chances of total tumor removal than the bifrontal and pterional approaches. Two independent factors for overall survival of patients with OGM were identified, namely age and WHO grade. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  9. Ecosystem partitioning of 15N-glycine after long-term climate and nutrient manipulations, plant clipping and addition of labile carbon in a subarctic heath tundra

    DEFF Research Database (Denmark)

    Sørensen, Pernille Lærkedal; Michelsen, Anders; Jonasson, Sven Evert

    2008-01-01

    of nitrogen (N). Here, we studied 15N label incorporation into microbes, plants and soil N pools after both long-term (12 years) climate manipulation and nutrient addition, plant clipping and a pulse-addition of labile C to the soil, in order to gain information on interactions among soil N and C pools...... addition. However, plants exerted control on the soil inorganic N concentrations and recovery of total dissolved 15N (TD15N), and likewise the microbes reduced these soil pools, but only when fed with labile C. Soil microbes in clipped plots were primarily C limited, and the findings of reduced N...... availability, both in the presence of plants and with the combined treatment of plant clipping and addition of sugar, suggest that the plant control of soil N pools was not solely due to plant uptake of soil N, but also partially caused by plants feeding labile C to the soil microbes, which enhanced...

  10. Use of Avoidance Tests for Investigating Potential of the Earthworm Eisenia fetida to Improve Composting of Grass Clippings

    NARCIS (Netherlands)

    Illmer, P.; Liebensteiner, M.

    2011-01-01

    The earthworm Eisenia fetida is the most commonly used worm for worm-supported composting of organic residues. Within the present study, the potential of E. fetida for decomposing grass clippings, an organic waste which usually causes anoxic conditions and thus insufficient degradation in the course

  11. CHANGES IN RENAL-FUNCTION INDUCED BY ACE-INHIBITION IN THE CONSCIOUS 2-KIDNEY, ONE-CLIP GOLDBLATT HYPERTENSIVE DOG

    NARCIS (Netherlands)

    JONKER, GJ; VISSCHER, CA; DEZEEUW, D; HUISMAN, RM; PIERS, DA; BEEKHUIS, H; VANDERHEM, GK

    In order to study why the diagnostic sensitivity of I-123-hippurate renography for a renal artery stenosis is improved by angiotensin converting enzyme (ACE-) inhibition we used the model of the conscious chronically instrumented two-kidney, one-clip Goldblatt hypertensive dog. Urine flow (UV),

  12. Glycation in human fingernail clippings using ATR-FTIR spectrometry, a new marker for the diagnosis and monitoring of diabetes mellitus.

    Science.gov (United States)

    Coopman, Renaat; Van de Vyver, Thijs; Kishabongo, Antoine Sadiki; Katchunga, Philippe; Van Aken, Elisabeth H; Cikomola, Justin; Monteyne, Tinne; Speeckaert, Marijn M; Delanghe, Joris R

    2017-01-01

    Although HbA1c is a good diagnostic tool for diabetes, the precarity of the health system and the costs limit the use of this biomarker in developing countries. Fingernail clippings contain ±85% of keratins, which are prone to glycation. Nail keratin glycation may reflect the average glycemia over the last months. We explored if attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) can be used as a non-invasive tool for assessing glycation in diabetes. Using ATR-FTIR spectroscopy, glycation and deglycation experiments with fructosamine 3-kinase allowed to identify the spectrum that corresponds with keratin glycation in fingernail clippings. Clippings of 105 healthy subjects and 127 diabetics were subjected to the standardized ATR-FTIR spectroscopy method. In vitro glycation resulted in an increased absorption at 1047cm -1 . Following enzymatic deglycation, this peak diminished significantly, proving that the AUC between 970 and 1140cm -1 corresponded with glycated proteins. Within-run CV of the assay was 3%. Storage of nail clippings at 37°C for 2weeks did not significantly change results. In diabetics, glycated nail protein concentrations (median: 1.51μmol/g protein, IQR: 1.37-1.85μmol/g protein) were significantly higher than in the controls (median: 1.19μmol/g protein, IQR: 1.09-1.26μmol/g protein) (p<0.0001). ROC analysis yielded an AUC of 0.92 at a cut-off point of 1.28μmol/g nail (specificity: 82%; sensitivity: 90%). No correlation was observed between the glycated nail protein concentrations and HbA1c. Protein glycation analysis in fingernails with ATR-FTIR spectroscopy could be an alternative affordable technique for diagnosing and monitoring diabetes. As the test does not consume reagents, and the preanalytical phase is extremely robust, the test could be particularly useful in developing countries. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. Comparative gas-exchange in leaves of intact and clipped, natural and planted cherrybark oak (Quercus pagoda Raf.) seedlings

    Science.gov (United States)

    Brian R. Lockhart; John D. Hodges

    2005-01-01

    Gas-exchange measurements, including C022-exchange rate (net photosynthesis), stomatal conductance, and transpiration, were conducted on intact and clipped cherrybark oak (Quercus pagoda Raf.) seedlings growing in the field and in a nursery bed. Seedlings in the field, released from midstory and understory woody competition,...

  14. [Surgical fixation of rib fractures with clips and titanium bars (STRATOS System). Preliminary experience].

    Science.gov (United States)

    Moreno De La Santa Barajas, Pablo; Polo Otero, María Dolores; Delgado Sánchez-Gracián, Carlos; Lozano Gómez, Manuel; Toscano Novella, Alberto; Calatayud Moscoso Del Prado, Julia; Leal Ruiloba, Sonsoles; Choren Durán, Maria L

    2010-09-01

    Rib fractures are very common in closed chest injuries. The majority of these patients suffer significant pain with movement and cough. The purpose of this study is to assess the usefulness of titanium rib bars and clips in stabilising rib fractures. Twenty-two patients with rib fractures were treated with open reduction and internal fixation between 2008 and 2009. Indications for treatment were defined as; 1) Patients with unstable chest (13 patients), 2) Patients with pain or instability due to rib fractures (6 patients), and 3) Significant traumatic deformities of the chest wall (3 patients). Age, traumatic mechanism, chest and associated injuries, surgical data, complications and follow-up were prospectively analysed. The surgical technique is described. The majority of patients were extubated immediately after surgery. All patients with pain or instability showed a subjective improvement or disappearance of pain after the surgery. Four patients had a wound infection which had to be drained. After 3 months, 55% of the patients had returned to work or normal life. The results in each group are described. Open reduction with internal fixation of rib fractures is a good alternative. The use of titanium rib bars and clips give good clinical results, are easy to apply and have few complications. Copyright © 2010 AEC. Published by Elsevier Espana. All rights reserved.

  15. Endoscopic and keyhole endoscope-assisted neurosurgical approaches: a qualitative survey on technical challenges and technological solutions.

    Science.gov (United States)

    Marcus, Hani J; Cundy, Thomas P; Hughes-Hallett, Archie; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar

    2014-10-01

    The literature reflects a resurgence of interest in endoscopic and keyhole endoscope-assisted neurosurgical approaches as alternatives to conventional microsurgical approaches in carefully selected cases. The aim of this study was to assess the technical challenges of neuroendoscopy, and the scope for technological innovations to overcome these barriers. All full members of the Society of British Neurosurgeons (SBNS) were electronically invited to participate in an online survey. The open-ended structured survey asked three questions; firstly, whether the surgeon presently utilises or has experience with endoscopic or endoscope-assisted approaches; secondly, what they consider to be the major technical barriers to adopting such approaches; and thirdly, what technological advances they foresee improving safety and efficacy in the field. Responses were subjected to a qualitative research method of multi-rater emergent theme analysis. Three clear themes emerged: 1) surgical approach and better integration with image-guidance systems (20%), 2) intra-operative visualisation and improvements in neuroendoscopy (49%), and 3) surgical manipulation and improvements in instruments (74%). The analysis of responses to our open-ended survey revealed that although opinion was varied three major themes could be identified. Emerging technological advances such as augmented reality, high-definition stereo-endoscopy, and robotic joint-wristed instruments may help overcome the technical difficulties associated with neuroendoscopic approaches. Results of this qualitative survey provide consensus amongst the technology end-user community such that unambiguous goals and priorities may be defined. Systems integrating these advances could improve the safety and efficacy of endoscopic and endoscope-assisted neurosurgical approaches.

  16. Occipital Artery Function during the Development of 2-Kidney, 1-Clip Hypertension in Rats

    OpenAIRE

    Stephen P. Chelko; Chad W. Schmiedt; Tristan H. Lewis; Tom P. Robertson; Stephen J. Lewis

    2014-01-01

    This study compared the contractile responses elicited by angiotensin II (AII), arginine vasopressin (AVP), and 5-hydroxytryptamine (5-HT) in isolated occipital arteries (OAs) from sham-operated (SHAM) and 2-kidney, 1-clip (2K-1C) hypertensive rats. OAs were isolated and bisected into proximal segments (closer to the common carotid artery) and distal segments (closer to the nodose ganglion) and mounted separately on myographs. On day 9, 2K-1C rats had higher mean arterial blood pressures, hea...

  17. Using Facebook and participant information clips to recruit emergency nurses for research.

    Science.gov (United States)

    Child, Rebekah Jay Howerton; Mentes, Janet C; Pavlish, Carol; Phillips, Linda R

    2014-07-01

    To examine the use of social networking sites in recruiting research participants. Workplace violence is an important issue for staff and patients. One workplace that reports the highest levels of violence is the emergency department. The ability to research issues such as workplace violence in real time is important in addressing them expeditiously, and social media can be used to advertise and recruit research subjects, implement studies and disseminate information. The experience of recruiting subjects through social networks, specifically Facebook, and the use of participant information clips (PICs) for advertising. A brief discussion of the history of advertising and communication using the internet is presented to provide an understanding of the trajectory of social media and implications for recruitment in general. The paper then focuses on the lead author's experience of recruiting subjects using Facebook, including its limitations and advantages, and her experience of using participant information clips. The low cost of advertising and recruiting participants this way, as well as the convenience provided to participants, resulted in almost half the study's total participants being obtained within 72 hours. Using Facebook to target a younger age range of nurses to participate in a study was successful and yielded a large number of completed responses in a short time period at little cost to the researcher. Recording the PIC was cheap, and posting it and a link to the site on pre-existing group pages was free, providing valuable viral marketing and snowball recruiting. Future researchers should not overlook using social network sites for recruitment if the demographics of the desired study population and subject matter permit it.

  18. Failure of acute procedural success predicts adverse outcome after percutaneous edge-to-edge mitral valve repair with MitraClip.

    Science.gov (United States)

    Puls, Miriam; Tichelbäcker, Tobias; Bleckmann, Annalen; Hünlich, Mark; von der Ehe, Katrin; Beuthner, Bo Eric; Rüter, Karin; Beißbarth, Tim; Seipelt, Ralf; Schöndube, Friedrich; Hasenfuß, Gerd; Schillinger, Wolfgang

    2014-01-01

    MitraClip implantation is evolving as a potential alternative treatment to conventional surgery in high-risk patients with significant mitral regurgitation (MR). However, outcome predictors are under-investigated. The aim of this study was to identify predictors of midterm mortality and heart failure rehospitalisation after percutaneous mitral valve repair with MitraClip. A total of 150 consecutive patients were followed for a median of 463 days. Survival analyses were performed for baseline characteristics, risk scores and failure of acute procedural success (APS) defined as persisting MR grade 3+ or 4+. Univariate significant risk stratifiers were tested in multivariate analyses using a Cox proportional hazards model. Overall survival was 96% at 30 days, 79.5% at 12 months, and 62% at two years. Multivariate analysis identified APS failure (HR 2.13, p=0.02), NYHA Class IV at baseline (HR 2.11, p=0.01) and STS score ≥12 (HR 2.20, pfailure (HR 2.31, p=0.01) and NYHA Class IV at baseline (HR 1.89, p=0.03) as significant independent predictors of heart failure rehospitalisation. Furthermore, a post-procedural significant decrease in hospitalisation rate could only be observed after successful interventions (0.89±1.07 per year before vs. 0.54±0.96 after implantation, p=0.01). Patients with severely dilated and overloaded ventricles who did not meet EVEREST II eligibility criteria were at higher risk of APS failure. The failure of acute procedural success proved to have the most important impact on outcome after MitraClip implantation.

  19. Combined use of clips and nylon snare ("tulip-bundle") as a rescue endoscopic bleeding control in a mallory-weiss syndrome.

    Science.gov (United States)

    Ivekovic, Hrvoje; Radulovic, Bojana; Jankovic, Suzana; Markos, Pave; Rustemovic, Nadan

    2014-01-01

    Mallory-Weiss syndrome (MWS) accounts for 6-14% of all cases of upper gastrointestinal bleeding. Prognosis of patients with MWS is generally good, with a benign course and rare recurrence of bleeding. However, no strict recommendations exist in regard to the mode of action after a failure of primary endoscopic hemostasis. We report a case of an 83-year-old male with MWS and rebleeding after the initial endoscopic treatment with epinephrine and clips. The final endoscopic control of bleeding was achieved by a combined application of clips and a nylon snare in a "tulip-bundle" fashion. The patient had an uneventful postprocedural clinical course and was discharged from the hospital five days later. To the best of our knowledge, this is the first case report showing the "tulip-bundle" technique as a rescue endoscopic bleeding control in the esophagus.

  20. Identification of CELF1 RNA targets by CLIP-seq in human HeLa cells

    Directory of Open Access Journals (Sweden)

    Olivier Le Tonquèze

    2016-06-01

    Full Text Available The specific interactions between RNA-binding proteins and their target RNAs are an essential level to control gene expression. By combining ultra-violet cross-linking and immunoprecipitation (CLIP and massive SoliD sequencing we identified the RNAs bound by the RNA-binding protein CELF1, in human HeLa cells. The CELF1 binding sites deduced from the sequence data allow characterizing specific features of CELF1-RNA association. We present therefore the first map of CELF1 binding sites in human cells.

  1. A systematic review on the safety and efficacy of percutaneous edge-to-edge mitral valve repair with the MitraClip system for high surgical risk candidates

    DEFF Research Database (Denmark)

    Munkholm-Larsen, Stine; Wan, Benjamin; Tian, David H

    2014-01-01

    BACKGROUND: MitraClip implantation has emerged as a viable option in high surgical risk patients with severe mitral regurgitation (MR). We performed the present systematic review to assess the safety and efficacy of the MitraClip system for high surgical risk candidates with severe organic and....../or functional MR. METHODS: Six electronic databases were searched for original published studies from January 2000 to March 2013. Two reviewers independently appraised studies, using a standard form, and extracted data on methodology, quality criteria, and outcome measures. All data were extracted and tabulated...

  2. ClipCard: Sharable, Searchable Visual Metadata Summaries on the Cloud to Render Big Data Actionable

    Science.gov (United States)

    Saripalli, P.; Davis, D.; Cunningham, R.

    2013-12-01

    Research firm IDC estimates that approximately 90 percent of the Enterprise Big Data go un-analyzed, as 'dark data' - an enormous corpus of undiscovered, untagged information residing on data warehouses, servers and Storage Area Networks (SAN). In the geosciences, these data range from unpublished model runs to vast survey data assets to raw sensor data. Many of these are now being collected instantaneously, at a greater volume and in new data formats. Not all of these data can be analyzed, nor processed in real time, and their features may not be well described at the time of collection. These dark data are a serious data management problem for science organizations of all types, especially ones with mandated or required data reporting and compliance requirements. Additionally, data curators and scientists are encouraged to quantify the impact of their data holdings as a way to measure research success. Deriving actionable insights is the foremost goal of Big Data Analytics (BDA), which is especially true with geoscience, given its direct impact on most of the pressing global issues. Clearly, there is a pressing need for innovative approaches to making dark data discoverable, measurable, and actionable. We report on ClipCard, a Cloud-based SaaS analytic platform for instant summarization, quick search, visualization and easy sharing of metadata summaries form the Dark Data at hierarchical levels of detail, thus rendering it 'white', i.e., actionable. We present a use case of the ClipCard platform, a cloud-based application which helps generate (abstracted) visual metadata summaries and meta-analytics for environmental data at hierarchical scales within and across big data containers. These summaries and analyses provide important new tools for managing big data and simplifying collaboration through easy to deploy sharing APIs. The ClipCard application solves a growing data management bottleneck by helping enterprises and large organizations to summarize, search

  3. Effect of gender on results of percutaneous edge-to-edge mitral valve repair with MitraClip system

    DEFF Research Database (Denmark)

    Estévez-Loureiro, Rodrigo; Settergren, Magnus; Winter, Reidar

    2015-01-01

    ≤II in 73.1% of men vs 74.2% of women, p = 0.912). After a mean follow-up period of 16.1 ± 11.1 months, no difference was found between groups in the incidence of death or admission for heart failure (log-rank p = 0.798). In conclusion, MitraClip implantation seems to be an equally safe and effective...

  4. Pilotless recovery of clipped OFDM signals by compressive sensing over reliable data carriers

    KAUST Repository

    Al-Safadi, Ebrahim B.

    2012-06-01

    In this paper we propose a novel method of clipping mitigation in OFDM using compressive sensing that completely avoids using reserved tones or channel-estimation pilots. The method builds on selecting the most reliable perturbations from the constellation lattice upon decoding at the receiver (in the frequency domain), and performs compressive sensing over these observations in order to completely recover the sparse nonlinear distortion in the time domain. As such, the method provides a practical solution to the problem of initial erroneous decoding decisions in iterative ML methods, and the ability to recover the distorted signal in one shot. © 2012 IEEE.

  5. Pilotless recovery of clipped OFDM signals by compressive sensing over reliable data carriers

    KAUST Repository

    Al-Safadi, Ebrahim B.; Al-Naffouri, Tareq Y.

    2012-01-01

    In this paper we propose a novel method of clipping mitigation in OFDM using compressive sensing that completely avoids using reserved tones or channel-estimation pilots. The method builds on selecting the most reliable perturbations from the constellation lattice upon decoding at the receiver (in the frequency domain), and performs compressive sensing over these observations in order to completely recover the sparse nonlinear distortion in the time domain. As such, the method provides a practical solution to the problem of initial erroneous decoding decisions in iterative ML methods, and the ability to recover the distorted signal in one shot. © 2012 IEEE.

  6. Learning Foreign Languages with ClipFlair: Using Captioning and Revoicing Activities to Increase Students' Motivation and Engagement

    Science.gov (United States)

    Baños, Rocío; Sokoli, Stavroula

    2015-01-01

    The purpose of this paper is to present the rationale and outcomes of ClipFlair, a European-funded project aimed at countering the factors that discourage Foreign Language Learning (FLL) by providing a motivating, easily accessible online platform to learn a foreign language through revoicing (e.g. dubbing) and captioning (e.g. subtitling). This…

  7. Elevated intracranial pressure and reversible eye-tracking changes detected while viewing a film clip.

    Science.gov (United States)

    Kolecki, Radek; Dammavalam, Vikalpa; Bin Zahid, Abdullah; Hubbard, Molly; Choudhry, Osamah; Reyes, Marleen; Han, ByoungJun; Wang, Tom; Papas, Paraskevi Vivian; Adem, Aylin; North, Emily; Gilbertson, David T; Kondziolka, Douglas; Huang, Jason H; Huang, Paul P; Samadani, Uzma

    2018-03-01

    OBJECTIVE The precise threshold differentiating normal and elevated intracranial pressure (ICP) is variable among individuals. In the context of several pathophysiological conditions, elevated ICP leads to abnormalities in global cerebral functioning and impacts the function of cranial nerves (CNs), either or both of which may contribute to ocular dysmotility. The purpose of this study was to assess the impact of elevated ICP on eye-tracking performed while patients were watching a short film clip. METHODS Awake patients requiring placement of an ICP monitor for clinical purposes underwent eye tracking while watching a 220-second continuously playing video moving around the perimeter of a viewing monitor. Pupil position was recorded at 500 Hz and metrics associated with each eye individually and both eyes together were calculated. Linear regression with generalized estimating equations was performed to test the association of eye-tracking metrics with changes in ICP. RESULTS Eye tracking was performed at ICP levels ranging from -3 to 30 mm Hg in 23 patients (12 women, 11 men, mean age 46.8 years) on 55 separate occasions. Eye-tracking measures correlating with CN function linearly decreased with increasing ICP (p short film clip. These results suggest that eye tracking may be used as a noninvasive, automatable means to quantitate the physiological impact of elevated ICP, which has clinical application for assessment of shunt malfunction, pseudotumor cerebri, concussion, and prevention of second-impact syndrome.

  8. A clip-based protocol for breast boost radiotherapy provides clear target visualisation and demonstrates significant volume reduction over time

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Lorraine [Department of Radiation Oncology, Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales (Australia); Cox, Jennifer [Department of Radiation Oncology, Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales (Australia); Faculty of Health Sciences, University of Sydney, Sydney, New South Wales (Australia); Morgia, Marita [Department of Radiation Oncology, Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales (Australia); Atyeo, John [Faculty of Health Sciences, University of Sydney, Sydney, New South Wales (Australia); Lamoury, Gillian [Department of Radiation Oncology, Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales (Australia)

    2015-09-15

    The clinical target volume (CTV) for early stage breast cancer is difficult to clearly identify on planning computed tomography (CT) scans. Surgical clips inserted around the tumour bed should help to identify the CTV, particularly if the seroma has been reabsorbed, and enable tracking of CTV changes over time. A surgical clip-based CTV delineation protocol was introduced. CTV visibility and its post-operative shrinkage pattern were assessed. The subjects were 27 early stage breast cancer patients receiving post-operative radiotherapy alone and 15 receiving post-operative chemotherapy followed by radiotherapy. The radiotherapy alone (RT/alone) group received a CT scan at median 25 days post-operatively (CT1rt) and another at 40 Gy, median 68 days (CT2rt). The chemotherapy/RT group (chemo/RT) received a CT scan at median 18 days post-operatively (CT1ch), a planning CT scan at median 126 days (CT2ch), and another at 40 Gy (CT3ch). There was no significant difference (P = 0.08) between the initial mean CTV for each cohort. The RT/alone cohort showed significant CTV volume reduction of 38.4% (P = 0.01) at 40 Gy. The Chemo/RT cohort had significantly reduced volumes between CT1ch: median 54 cm{sup 3} (4–118) and CT2ch: median 16 cm{sup 3}, (2–99), (P = 0.01), but no significant volume reduction thereafter. Surgical clips enable localisation of the post-surgical seroma for radiotherapy targeting. Most seroma shrinkage occurs early, enabling CT treatment planning to take place at 7 weeks, which is within the 9 weeks recommended to limit disease recurrence.

  9. A clip-based protocol for breast boost radiotherapy provides clear target visualisation and demonstrates significant volume reduction over time

    International Nuclear Information System (INIS)

    Lewis, Lorraine; Cox, Jennifer; Morgia, Marita; Atyeo, John; Lamoury, Gillian

    2015-01-01

    The clinical target volume (CTV) for early stage breast cancer is difficult to clearly identify on planning computed tomography (CT) scans. Surgical clips inserted around the tumour bed should help to identify the CTV, particularly if the seroma has been reabsorbed, and enable tracking of CTV changes over time. A surgical clip-based CTV delineation protocol was introduced. CTV visibility and its post-operative shrinkage pattern were assessed. The subjects were 27 early stage breast cancer patients receiving post-operative radiotherapy alone and 15 receiving post-operative chemotherapy followed by radiotherapy. The radiotherapy alone (RT/alone) group received a CT scan at median 25 days post-operatively (CT1rt) and another at 40 Gy, median 68 days (CT2rt). The chemotherapy/RT group (chemo/RT) received a CT scan at median 18 days post-operatively (CT1ch), a planning CT scan at median 126 days (CT2ch), and another at 40 Gy (CT3ch). There was no significant difference (P = 0.08) between the initial mean CTV for each cohort. The RT/alone cohort showed significant CTV volume reduction of 38.4% (P = 0.01) at 40 Gy. The Chemo/RT cohort had significantly reduced volumes between CT1ch: median 54 cm 3 (4–118) and CT2ch: median 16 cm 3 , (2–99), (P = 0.01), but no significant volume reduction thereafter. Surgical clips enable localisation of the post-surgical seroma for radiotherapy targeting. Most seroma shrinkage occurs early, enabling CT treatment planning to take place at 7 weeks, which is within the 9 weeks recommended to limit disease recurrence

  10. Guided asteroid deflection by kinetic impact: Mapping keyholes to an asteroid's surface

    Science.gov (United States)

    Chesley, S.; Farnocchia, D.

    2014-07-01

    range from around 1 for a porous, compressible body producing negligible ejecta, to 2 when the ejecta momentum matches the spacecraft momentum, and as high as 5--10 for rocky bodies that produce large, high-velocity ejecta fragments. If the impactor hits the centerpoint of a spherical asteroid the momentum of the escaping ejecta directly adds to the momentum of the impacting asteroid, but if the impact is oblique then the ejecta and spacecraft momenta are added to the asteroid in vector sum. This suggests the possibility that for a given intercept trajectory the asteroid deflection could include guidance by targeting an oblique impact that could steer the asteroid Δ V to a more optimal direction that is different from the relative velocity direction of the spacecraft. An oblique impact decreases the net Δ V magnitude, and yet could significantly increase the net deflection at the time of the threatening Earth encounter. We use asteroid (101955) Bennu, which is the target of the OSIRIS-REx asteroid sample return mission and which has a series of potential Earth impacts in the years from 2175--2196, as an example to demonstrate the effectiveness of the oblique impact. These future potential impacts will occur if the asteroid passes through one of a series of keyholes when the asteroid passes the Earth at roughly the lunar distance from the Earth in 2135. To study the Bennu deflection problem we simulate a hypervelocity spacecraft impact on Bennu in March 2021, after the OSIRIS-REx mission is complete. In our example, the spacecraft arrives from approximately the sunward direction, and targeting ahead or behind the center of the asteroid allows non-negligible transverse accelerations for modest values of β. A given impact location on the asteroid surface yields a given Δ V vector, and our approach starts by mapping the net Δ V components on the surface for an assumed value of β. Knowing the mapping from impact location to Δ V and also the mapping from Δ V to the

  11. Economic evaluation of Community Level Interventions for Pre-eclampsia (CLIP) in South Asian and African countries: a study protocol.

    Science.gov (United States)

    Khowaja, Asif R; Mitton, Craig; Bryan, Stirling; Magee, Laura A; Bhutta, Zulfiqar A; von Dadelszen, Peter

    2015-05-26

    Globally, hypertensive disorders of pregnancy, particularly pre-eclampsia and eclampsia, are the leading cause of maternal and neonatal mortality, and impose substantial burdens on the families of pregnant women, their communities, and healthcare systems. The Community Level Interventions for Pre-eclampsia (CLIP) Trial evaluates a package of care applied at both community and primary health centres to reduce maternal and perinatal disabilities and deaths resulting from the failure to identify and manage pre-eclampsia at the community level. Economic evaluation of health interventions can play a pivotal role in priority setting and inform policy decisions for scale-up. At present, there is a paucity of published literature on the methodology of economic evaluation of large, multi-country, community-based interventions in the area of maternal and perinatal health. This study protocol describes the application of methodology for economic evaluation of the CLIP in South Asia and Africa. A mixed-design approach i.e. cost-effectiveness analysis (CEA) and qualitative thematic analysis will be used alongside the trial to prospectively evaluate the economic impact of CLIP from a societal perspective. Data on health resource utilization, costs, and pregnancy outcomes will be collected through structured questionnaires embedded into the pregnancy surveillance, cross-sectional survey and budgetary reviews. Qualitative data will be collected through focus groups (FGs) with pregnant women, household male-decision makers, care providers, and district level health decision makers. The incremental cost-effectiveness ratio will be calculated for healthcare system and societal perspectives, taking into account the country-specific model inputs (costs and outcome) from the CLIP Trial. Emerging themes from FGs will inform the design of the model, and help to interpret findings of the CEA. The World Health Organization (WHO) strongly recommends cost-effective interventions as a key

  12. Antihypertensive therapy induces compartment-specific chemokine expression and a Th1 immune response in the clipped kidney of Goldblatt hypertensive rats

    NARCIS (Netherlands)

    Steinmetz, O. M.; Sadaghiani, S.; Panzer, U.; Krebs, C.; Meyer-Schwesinger, C.; Streichert, T.; Fehr, S.; Hamming, I.; van Goor, H.; Stahl, R. A. K.; Wenzel, U.

    The present study examined the pathogenesis of interstitial inflammation and fibrosis in antihypertensively treated rats with two-kidney, one-clip hypertension. Hypertensive rats were randomized into four groups: no treatment and moderate, intermediate, and intensified lowering of blood pressure

  13. Prosthetic aspects and patient satisfaction with resilient liner and clip attachments for bar- and implant-retained mandibular overdentures: a 3-year randomized clinical study.

    Science.gov (United States)

    ELsyad, Moustafa Abdou

    2012-01-01

    This report aimed to compare prosthetic aspects and patient satisfaction during a 3-year randomized clinical trial of bar- and implant-retained mandibular overdentures attached with either resilient liners or clips. Thirty edentulous male patients (mean age: 62.5 years) received two implants in the anterior mandible after being allocated into two equal groups (according to attachment type received) using balanced randomization. After 3 months, implants were connected with resilient bars. New maxillary complete dentures were then constructed, and mandibular overdentures were retained to the bars with either clips (group I) or silicone resilient liners (group II). Subjects indicated satisfaction with their prostheses using a questionnaire and visual analog scale. Patient satisfaction and prosthetic complications were recorded for both attachments at 6 months and 1 and 3 years after overdenture insertion. Comfort and stability with the maxillary denture and ease of hygiene procedures were rated higher in group II, while ease of handling the dentures was rated higher in group I. No significant differences in other parameters of patient satisfaction between groups were noted after 3 years. The mean number of prosthetic adjustments and repairs in group I (11.9) was significantly higher (P = .00) compared to that in group II (4.8). The most common complication in group I was clip wear, while separation of the resilient liner from the denture base was the most common problem in group II. Hyperplasia under the bar and flabby ridge in the maxilla occurred significantly more often in group I compared to group II. Resilient liner-retained mandibular overdentures had comparable patient satisfaction, less prosthetic maintenance and costs, and less soft tissue complications when compared to clip-retained ones after 3 years.

  14. Survival Prediction in Patients Undergoing Open-Heart Mitral Valve Operation After Previous Failed MitraClip Procedures.

    Science.gov (United States)

    Geidel, Stephan; Wohlmuth, Peter; Schmoeckel, Michael

    2016-03-01

    The objective of this study was to analyze the results of open heart mitral valve operations for survival prediction in patients with previously unsuccessful MitraClip procedures. Thirty-three consecutive patients who underwent mitral valve surgery in our institution were studied. At a median of 41 days, they had previously undergone one to five futile MitraClip implantations. At the time of their operations, patients were 72.6 ± 10.3 years old, and the calculated risk, using the European System for Cardiac Operative Risk Evaluation (EuroSCORE) II, was a median of 26.5%. Individual outcomes were recorded, and all patients were monitored postoperatively. Thirty-day mortality was 9.1%, and the overall survival at 2.2 years was 60.6%. Seven cardiac-related and six noncardiac deaths occurred. Univariate survival regression models demonstrated a significant influence of the following variables on survival: EuroSCORE II (p = 0.0022), preoperative left ventricular end-diastolic dimension (p = 0.0052), left ventricular ejection fraction (p = 0.0249), coronary artery disease (p = 0.0385), and severe pulmonary hypertension (p = 0.0431). Survivors showed considerable improvements in their New York Heart Association class (p < 0.0001), left ventricular ejection fraction (p = 0.0080), grade of mitral regurgitation (p = 0.0350), and mitral valve area (p = 0.0486). Survival after mitral repair was not superior to survival after replacement. Indications for surgery after failed MitraClip procedures must be considered with the greatest of care. Variables predicting postoperative survival should be taken into account regarding the difficult decision as to whether to operate or not. Our data suggest that replacement of the pretreated mitral valve is probably the more reasonable concept rather than complex repairs. When the EuroSCORE II at the time of surgery exceeds 30%, conservative therapy is advisable. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc

  15. Combined Use of Clips and Nylon Snare (“Tulip-Bundle” as a Rescue Endoscopic Bleeding Control in a Mallory-Weiss Syndrome

    Directory of Open Access Journals (Sweden)

    Hrvoje Ivekovic

    2014-01-01

    Full Text Available Mallory-Weiss syndrome (MWS accounts for 6–14% of all cases of upper gastrointestinal bleeding. Prognosis of patients with MWS is generally good, with a benign course and rare recurrence of bleeding. However, no strict recommendations exist in regard to the mode of action after a failure of primary endoscopic hemostasis. We report a case of an 83-year-old male with MWS and rebleeding after the initial endoscopic treatment with epinephrine and clips. The final endoscopic control of bleeding was achieved by a combined application of clips and a nylon snare in a “tulip-bundle” fashion. The patient had an uneventful postprocedural clinical course and was discharged from the hospital five days later. To the best of our knowledge, this is the first case report showing the “tulip-bundle” technique as a rescue endoscopic bleeding control in the esophagus.

  16. Neurosurgeon academic impact is associated with clinical outcomes after clipping of ruptured intracranial aneurysms.

    Science.gov (United States)

    Alotaibi, Naif M; Ibrahim, George M; Wang, Justin; Guha, Daipayan; Mamdani, Muhammad; Schweizer, Tom A; Macdonald, R Loch

    2017-01-01

    Surgeon-dependent factors such as experience and volume are associated with patient outcomes. However, it is unknown whether a surgeon's research productivity could be related to outcomes. The main aim of this study is to investigate the association between the surgeon's academic productivity and clinical outcomes following neurosurgical clipping of ruptured aneurysms. We performed a post-hoc analysis of 3567 patients who underwent clipping of ruptured intracranial aneurysms in the randomized trials of tirilazad mesylate from 1990 to 1997. These trials included 162 centers and 156 surgeons from 21 countries. Primary and secondary outcomes were: Glasgow outcome scale score and mortality, respectively. Total publications, H-index, and graduate degrees were used as academic indicators for each surgeon. The association between outcomes and academic factors were assessed using a hierarchical logistic regression analysis, adjusting for patient covariates. Academic profiles were available for 147 surgeons, treating a total of 3307 patients. Most surgeons were from the USA (62, 42%), Canada (18, 12%), and Germany (15, 10%). On univariate analysis, the H-index correlated with better functional outcomes and lower mortality rates. In the multivariate model, patients under the care of surgeons with higher H-indices demonstrated improved neurological outcomes (p = 0.01) compared to surgeons with lower H-indices, without any significant difference in mortality. None of the other academic indicators were significantly associated with outcomes. Although prognostication following surgery for ruptured intracranial aneurysms primarily depends on clinical and radiological factors, the academic impact of the operating neurosurgeon may explain some heterogeneity in surgical outcomes.

  17. Water and exchangeable sodium in Goldblatt two-kidney, two-clip hypertensive rats

    International Nuclear Information System (INIS)

    Mac Cormack, W.P.; Roson, M.I.; Maquieira, M.K.; Mendez, M.A.; Santoro, F.M.; Morera, S.; de la Riva, I.J.

    1986-01-01

    Exchangeable 22 Na (ExNa), total body water (TBW) and the inulin space (InSp) were determined in two-kidney, two-clip (2K-2C) hypertensive and sham operated (normotensive) control rats 6-8 weeks after surgery. TBW (ml/kg lean body weight) was the same in hypertensive and sham rats. In contrast, ExNa (mEq/kglbw) and InSp (ml/kglbw) significantly increased (p less than 0.01) in rats whose hypertension did not exceed 170 mmHg. Consequently, sham, moderate hypertensive (less than 170 mmHg) and severe hypertensive (less than 170 mmHg) animals showed equal TBW but differed in body water distribution in that moderately hypertensive animals displayed a redistribution of water in favor of the extracellular space

  18. Surgical clipping of flow related giant unruptured anterior spinal artery aneurysm secondary to co-arctation of aorta: Management challenges and lessons learnt

    Directory of Open Access Journals (Sweden)

    Jeena Joseph

    2017-12-01

    Conclusion: ASAA remains an extremely rare cause of compressive myelopathy. Its association with co-arctation of aorta increases treatment related mortality. Posterolateral approach provides a good exposure of the aneurysm for surgical clipping with minimal retraction of the cord.

  19. Numerical simulation of spatter formation during fiber laser welding of 5083 aluminum alloy at full penetration condition

    Science.gov (United States)

    Wu, Dongsheng; Hua, Xueming; Huang, Lijin; Zhao, Jiang

    2018-03-01

    The droplet escape condition in laser welding is established in this paper. A three-dimensional numerical model is developed to study the weld pool convection and spatter formation at full penetration during the fiber laser welding of 5083 aluminum alloy. It is found that when laser power is 9 kW, the bottom of the keyhole is dynamically opened and closed. When the bottom of the keyhole is closed, the molten metal at the bottom of the back keyhole wall flows upwards along the fusion line. When the bottom of the keyhole is opened, few spatters can be seen around the keyhole at the top surface, two flow patterns exists in the rear part of the keyhole: a portion of molten metal flows upwards along the fusion line, other portion of molten metal flows to the bottom of the keyhole, which promote the spatter formation at the bottom of the keyhole rear wall.

  20. Comparativa de la reparación valvular mitral y el dispositivo MitraClip® en el tratamiento de la insuficiencia mitral severa

    Directory of Open Access Journals (Sweden)

    Isabel Pernía-Oreña

    2017-03-01

    Conclusiones: El dispositivo MitraClip®, en este grupo de bajo riesgo, mostró peores resultados con mayor mortalidad, reingresos, descompensaciones y alta tasa de insuficiencia mitral residual. Podría ser una alternativa en casos desestimados de cirugía.

  1. Using CLIPS in a distributed system: The Network Control Center (NCC) expert system

    Science.gov (United States)

    Wannemacher, Tom

    1990-01-01

    This paper describes an intelligent troubleshooting system for the Help Desk domain. It was developed on an IBM-compatible 80286 PC using Microsoft C and CLIPS and an AT&T 3B2 minicomputer using the UNIFY database and a combination of shell script, C programs and SQL queries. The two computers are linked by a lan. The functions of this system are to help non-technical NCC personnel handle trouble calls, to keep a log of problem calls with complete, concise information, and to keep a historical database of problems. The database helps identify hardware and software problem areas and provides a source of new rules for the troubleshooting knowledge base.

  2. ART/Ada and CLIPS/Ada

    Science.gov (United States)

    Culbert, Chris

    1990-01-01

    Although they have reached a point of commercial viability, expert systems were originally developed in artificial intelligence (AI) research environments. Many of the available tools still work best in such environments. These environments typically utilize special hardware such as LISP machines and relatively unfamiliar languages such as LISP or Prolog. Space Station applications will require deep integration of expert system technology with applications developed in conventional languages, specifically Ada. The ability to apply automation to Space Station functions could be greatly enhanced by widespread availability of state-of-the-art expert system tools based on Ada. Although there have been some efforts to examine the use of Ada for AI applications, there are few, if any, existing products which provide state-of-the-art AI capabilities in an Ada tool. The goal of the ART/Ada Design Project is to conduct research into the implementation in Ada of state-of-the-art hybrid expert systems building tools (ESBT's). This project takes the following approach: using the existing design of the ART-IM ESBT as a starting point, analyze the impact of the Ada language and Ada development methodologies on that design; redesign the system in Ada; and analyze its performance. The research project will attempt to achieve a comprehensive understanding of the potential for embedding expert systems in Ada systems for eventual application in future Space Station Freedom projects. During Phase 1 of the project, initial requirements analysis, design, and implementation of the kernel subset of ART-IM functionality was completed. During Phase 2, the effort has been focused on the implementation and performance analysis of several versions with increasing functionality. Since production quality ART/Ada tools will not be available for a considerable time, and additional subtask of this project will be the completion of an Ada version of the CLIPS expert system shell developed by NASA

  3. Controle dos vasos renais usando clips vasculares e fio cirúrgico em nefrectomias vídeo-assistidas de doadores vivos

    Directory of Open Access Journals (Sweden)

    Alcides José Branco Filho

    Full Text Available OBJETIVO: A nefrectomia laparoscópica em doadores vivos para transplante renal vem assumindo um papel importante na era das cirurgias minimamente invasivas, acarretando menor morbidade aos doadores, e resultados semelhantes à técnica aberta no que se refere ao enxerto renal. O objetivo do presente artigo é relatar a experiência do nosso serviço utilizando a técnica de controle dos vasos renais usando fio cirúrgico e clips vasculares. MÉTODO: Foram realizadas 45 nefrectomias utilizando a técnica vídeo-assistida, com ligadura dos vasos renais com clips de titânio (LT-300 e fio cirúrgico. As variáveis analisadas foram tempo cirúrgico, perda sangüínea, tempo de isquemia quente, permanência hospitalar, necessidade de conversão e complicações. RESULTADOS: O procedimento foi realizado com sucesso em todos os casos. O tempo cirúrgico médio foi de 118 minutos, com perda sangüínea estimada em 84ml e tempo de isquemia quente de 4,3 minutos. Dois casos de íleo prolongado, uma lesão de veia gonadal, um escape de artéria renal e uma necrose de ureter foram observados. A permanência hospitalar média foi de 3,7 dias. O uso de clips vasculares e fio cirúrgico reduziu a perda de tecido venoso comparado à técnica com staplers e gerou redução de custos. CONCLUSÕES: A nefrectomia vídeo-assistida com a técnica descrita é factível e mostrou ser efetiva na contenção de gastos e na redução de tecido venoso perdido.

  4. Temporo-sylvian anastomosis and aneurysm clipping in a case of left M1 aneurysm with progressive evolution after initial embolization; Case report

    Directory of Open Access Journals (Sweden)

    Ion Georgiana

    2015-06-01

    Full Text Available A giant unrupted middle cerebral artery aneurysm partially thrombosed, previously endovascularly treated after a mild right hemiparesis remitted. After 12 months, in routine check we discovered a reperfusion of the aneurysm and decide ECIC bypass and clipping, with a good outcome

  5. Acute limb ischemia caused by incorrect deployment of a clip-based arterial closure device

    Directory of Open Access Journals (Sweden)

    Łukasz Dzieciuchowicz

    2016-04-01

    Full Text Available Failure of a vascular closure device most commonly results in a hemorrhage or pseudoaneurysm formation. In this paper a rare case of severe acute limb ischemia following incorrect deployment of a clip-based closure device (Starclose SE, Abbott Vascular in a 31-year-old woman is presented. Symptoms of acute limb ischemia occurred at the start of the ambulation, 6 h after completion of the procedure. Because of the severity of ischemia the patient was treated surgically, and limb perfusion was successfully restored. An attempt of closure of an inadvertently punctured narrow superficial femoral artery was identified as the cause of this complication.

  6. A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery

    International Nuclear Information System (INIS)

    Ding, Yun; Li, Jianbin; Wang, Wei; Wang, Suzhen; Wang, Jinzhi; Ma, Zhifang; Shao, Qian; Xu, Min

    2014-01-01

    To explore the volume and localization of the internal gross target volume defined using the seroma and/or surgical clips based on the four-dimensional computed tomography (4DCT) during free-breathing. Fifteen breast cancer patients after breast-conserving surgery (BCS) were recruited for EB-PBI. On the ten sets CT images, the gross target volume formed by the clips, the seroma, both the clips and seroma delineated by one radiation oncologist and defined as GTVc, GTVs and GTVc + s, respectively. The ten GTVc, GTVs and GTVc + s on the ten sets CT images produced the IGTVc, IGTVs, IGTVc + s, respectively. The IGTV volume and the distance between the center of IGTVc, IGTVs, IGTVc + s were all recorded. Conformity index (CI), degree of inclusion (DI) were calculated for IGTV/IGTV, respectively. The volume of IGTVc + s were significantly larger than the IGTVc and IGTVs (p < 0.05). There was significant difference between the DIs of IGTVc vs IGTVc + s, the DIs of IGTVs vs IGTVc + s. There was significant difference among the CIs of IGTV/IGTV. The DIs and CIs of IGTV/IGTV were negatively correlated with their centroid distance (r < 0, p < 0.05). There were volume difference and spatial mismatch between the IGTVs delineated based on the surgical clips and seroma. The IGTV defined as the seroma and surgical clips provided the best overall representation of the ‘true’ moving GTV

  7. Surgical outcome of primary clipping for anterior circulation aneurysms of size 2 centimeters or larger.

    Science.gov (United States)

    Furtado, Sunil V; Saikiran, Narayanam A; Thakar, Sumit; Dadlani, Ravi; Mohan, Dilip; Aryan, Saritha; Hegde, Alangar S

    2014-07-01

    Aneurysms of the anterior circulation larger than 2cm have a complex relationship to the anterior skull base, requiring a multi-modality management approach. This retrospective study of 54 patients with such aneurysms who underwent clipping between 2001 and 2012 analyzes clinical and surgical data, aneurysm characteristics and correlates them with respect to the Glasgow outcome score at follow-up and immediate post-operative clinical status. Patients with an outcome score of 5 or 4 were categorized as "good", while those with score 3-1 were "poor". Fisher's exact test and paired T-test (p<0.5) were used to test statistical significance for discrete and continuous variables respectively. 44 (81.4%) patients had a good outcome. Patients with non-ophthalmic/paraclinoid aneurysms had significantly lower incidence of adverse intra-operative events (p=0.035). Patients older than 50 years (p=0.045), with adverse intra-operative events (p=0.015) and post-operative infarction (p<0.001) had a poor outcome compared to those younger than 50 years age and those without adverse intra-operative events or infarctions. The grouped age variable had maximum influence on patient outcome. Location and size of aneurysm did not have an overall impact on surgical outcome. There were 4 mortalities. Primary clipping of proximal non-cavernous aneurysms on the internal carotid artery is associated with adverse intra-operative events. A multi-modality treatment approach in these aneurysms should be individualized, more so in patients older than 50 years. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Comparison of potassium hydroxide mount and mycological culture with histopathologic examination using periodic acid-Schiff staining of the nail clippings in the diagnosis of onychomycosis.

    Science.gov (United States)

    Shenoy, M Manjunath; Teerthanath, S; Karnaker, Vimal K; Girisha, B S; Krishna Prasad, M S; Pinto, Jerome

    2008-01-01

    Onychomycosis is a common problem noticed in clinical practice. Currently available standard laboratory methods show inconsistent sensitivity; hence there is a need for newer methods of detection. This study involves comparison of standard laboratory tests in the diagnosis of onychomycosis, namely, potassium hydroxide mount (KOH mount) and mycological culture, with histopathologic examination using periodic acid-Schiff (PAS) staining of the nail clippings. A total of 101 patients with clinically suspected onychomycosis were selected. Nail scrapings and clippings were subjected to KOH mount for direct microscopic examination, culture using Sabouraud's dextrose agar (with and without antibiotics) and histopathologic examination with PAS staining (HP/PAS). Statistical analysis was done by McNemar's test. Direct microscopy with KOH mount, mycological culture, and HP/PAS showed positive results in 54 (53%), 35 (35%), and 76 (75%) patients respectively. Laboratory evidence of fungal infection was obtained in 84 samples by at least one of these three methods. Using this as the denominator, HP/PAS had a sensitivity of 90%, which was significantly higher compared to that of KOH mount (64%) or mycological culture (42%). Histopathologic diagnosis with PAS staining of nail clippings was the most sensitive among the tests. It was easy to perform, rapid, and gave significantly higher rates of detection of onychomycosis compared to the standard methods, namely KOH mount and mycological culture.

  9. Neighbour effects on Erica multiflora (Ericaceae) reproductive performance after clipping

    Science.gov (United States)

    Vilà, Montserrat; Terradas, Jaume

    1998-04-01

    The effect of interspecific competition on resprouting and reproductive success and the relationship between above-ground vegetative biomass variability and reproductive biomass variability were analysed during resprouting after clipping. For this purpose, a field experiment was performed by removing neighbours around individuals of Erica multiflora in a Mediterranean shrub community. Removal of neighbours increased the number of sprouts and the above-ground vegetative biomass of target plants. However, it did not decrease plant size variability. Neighbours decreased the likelihood of fruiting and the biomass of fruits. In target plants that had set fruits a simple allometric relationship between above-ground vegetative biomass and the biomass of fruits explained 42% of the variation in fruit biomass. The probability to set fruits at a given plant size was smaller in plants with neighbours than without neighbours. Presence of neighbours also increased the variability of fruit biomass within the population, because 50% of target plants with neighbours did not set fruits. This failure to set fruits may be related to shading, the small size of plants with neighbours, as well as a delay in development.

  10. Microsurgical Clipping of an Anterior Communicating Artery Aneurysm Using a Novel Robotic Visualization Tool in Lieu of the Binocular Operating Microscope: Operative Video.

    Science.gov (United States)

    Klinger, Daniel R; Reinard, Kevin A; Ajayi, Olaide O; Delashaw, Johnny B

    2018-01-01

    The binocular operating microscope has been the visualization instrument of choice for microsurgical clipping of intracranial aneurysms for many decades. To discuss recent technological advances that have provided novel visualization tools, which may prove to be superior to the binocular operating microscope in many regards. We present an operative video and our operative experience with the BrightMatterTM Servo System (Synaptive Medical, Toronto, Ontario, Canada) during the microsurgical clipping of an anterior communicating artery aneurysm. To the best of our knowledge, the use of this device for the microsurgical clipping of an intracranial aneurysm has never been described in the literature. The BrightMatterTM Servo System (Synaptive Medical) is a surgical exoscope which avoids many of the ergonomic constraints of the binocular operating microscope, but is associated with a steep learning curve. The BrightMatterTM Servo System (Synaptive Medical) is a maneuverable surgical exoscope that is positioned with a directional aiming device and a surgeon-controlled foot pedal. While utilizing this device comes with a steep learning curve typical of any new technology, the BrightMatterTM Servo System (Synaptive Medical) has several advantages over the conventional surgical microscope, which include a relatively unobstructed surgical field, provision of high-definition images, and visualization of difficult angles/trajectories. This device can easily be utilized as a visualization tool for a variety of cranial and spinal procedures in lieu of the binocular operating microscope. We anticipate that this technology will soon become an integral part of the neurosurgeon's armamentarium. Copyright © 2017 by the Congress of Neurological Surgeons

  11. Experimental and numerical study of spatter formation and composition change in fiber laser welding of aluminum alloy

    Science.gov (United States)

    Wu, Dongsheng; Hua, Xueming; Ye, Youxiong; Huang, Lijin; Li, Fang; Huang, Ye

    2018-05-01

    A laser welding experiment with glass is conducted to directly observe the keyhole behavior and spatter formation in fiber laser welding of aluminum alloy. A 3D model is developed to investigate the spatter formation and composition change. An additional conservation equation is introduced to describe the Mg element distribution, and the Mg element loss due to evaporation is also considered. Based on numerical and experimental results, it is found that the keyhole geometry in laser welding of aluminum alloy is different from that in laser welding of steel. There are three required steps for spatter formation around the keyhole. The high momentum of the molten metal, the high recoil pressure and vapor shear stress, and the low surface tension around the keyhole contribute to the easy formation of spatter. The in-homogeneous distribution of Mg element in the weld can be attributable to the continuous evaporation of Mg element at the top surface of keyhole rear, the upward flow of low Mg element region from the bottom of the keyhole to the top surface of keyhole rear along the fusion line, the collapse of the keyhole, and the ejection of spatters.

  12. Local Contrast Enhancement Utilizing Bidirectional Switching Equalization of Separated and Clipped Subhistograms

    Directory of Open Access Journals (Sweden)

    Haidi Ibrahim

    2014-01-01

    Full Text Available Digital image contrast enhancement methods that are based on histogram equalization technique are still useful for the use in consumer electronic products due to their simple implementation. However, almost all the suggested enhancement methods are using global processing technique, which does not emphasize local contents. Therefore, this paper proposes a new local image contrast enhancement method, based on histogram equalization technique, which not only enhances the contrast, but also increases the sharpness of the image. Besides, this method is also able to preserve the mean brightness of the image. In order to limit the noise amplification, this newly proposed method utilizes local mean-separation, and clipped histogram bins methodologies. Based on nine test color images and the benchmark with other three histogram equalization based methods, the proposed technique shows the best overall performance.

  13. Follow-up CT and CT angiography after intracranial aneurysm clipping and coiling - improved image quality by iterative metal artifact reduction

    Energy Technology Data Exchange (ETDEWEB)

    Bier, Georg; Hempel, Johann-Martin; Oergel, Anja; Hauser, Till-Karsten; Ernemann, Ulrike; Hennersdorf, Florian [Eberhard Karls University Tuebingen, Department of Diagnostic and Interventional Neuroradiology, Tuebingen (Germany); Bongers, Malte Niklas [Eberhard Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2017-07-15

    This paper aims to evaluate a new iterative metal artifact reduction algorithm for post-interventional evaluation of brain tissue and intracranial arteries. The data of 20 patients that underwent follow-up cranial CT and cranial CT angiography after clipping or coiling of an intracranial aneurysm was retrospectively analyzed. After the images were processed using a novel iterative metal artifact reduction algorithm, images with and without metal artifact reduction were qualitatively evaluated by two readers, using a five-point Likert scale. Moreover, artifact strength was quantitatively assessed in terms of CT attenuation and standard deviation alterations. The qualitative analysis yielded a significant increase in image quality (p = 0.0057) in iteratively processed images with substantial inter-observer agreement (k = 0.72), while the CTA image quality did not differ (p = 0.864) and even showed vessel contrast reduction in six cases (30%). The mean relative attenuation difference was 27% without metal artifact reduction vs. 11% for iterative metal artifact reduction images (p = 0.0003). The new iterative metal artifact reduction algorithm enhances non-enhanced CT image quality after clipping or coiling, but in CT-angiography images, the contrast of adjacent vessels can be compromised. (orig.)

  14. Follow-up CT and CT angiography after intracranial aneurysm clipping and coiling - improved image quality by iterative metal artifact reduction

    International Nuclear Information System (INIS)

    Bier, Georg; Hempel, Johann-Martin; Oergel, Anja; Hauser, Till-Karsten; Ernemann, Ulrike; Hennersdorf, Florian; Bongers, Malte Niklas

    2017-01-01

    This paper aims to evaluate a new iterative metal artifact reduction algorithm for post-interventional evaluation of brain tissue and intracranial arteries. The data of 20 patients that underwent follow-up cranial CT and cranial CT angiography after clipping or coiling of an intracranial aneurysm was retrospectively analyzed. After the images were processed using a novel iterative metal artifact reduction algorithm, images with and without metal artifact reduction were qualitatively evaluated by two readers, using a five-point Likert scale. Moreover, artifact strength was quantitatively assessed in terms of CT attenuation and standard deviation alterations. The qualitative analysis yielded a significant increase in image quality (p = 0.0057) in iteratively processed images with substantial inter-observer agreement (k = 0.72), while the CTA image quality did not differ (p = 0.864) and even showed vessel contrast reduction in six cases (30%). The mean relative attenuation difference was 27% without metal artifact reduction vs. 11% for iterative metal artifact reduction images (p = 0.0003). The new iterative metal artifact reduction algorithm enhances non-enhanced CT image quality after clipping or coiling, but in CT-angiography images, the contrast of adjacent vessels can be compromised. (orig.)

  15. sCLIP-an integrated platform to study RNA-protein interactomes in biomedical research: identification of CSTF2tau in alternative processing of small nuclear RNAs.

    Science.gov (United States)

    Kargapolova, Yulia; Levin, Michal; Lackner, Karl; Danckwardt, Sven

    2017-06-02

    RNA-binding proteins (RBPs) are central for gene expression by controlling the RNA fate from birth to decay. Various disorders arising from perturbations of RNA-protein interactions document their critical function. However, deciphering their function is complex, limiting the general functional elucidation of this growing class of proteins and their contribution to (patho)physiology. Here, we present sCLIP, a simplified and robust platform for genome-wide interrogation of RNA-protein interactomes based on crosslinking-immunoprecipitation and high-throughput sequencing. sCLIP exploits linear amplification of the immunoprecipitated RNA improving the complexity of the sequencing-library despite significantly reducing the amount of input material and omitting several purification steps. Additionally, it permits a radiolabel-free visualization of immunoprecipitated RNA. In a proof of concept, we identify that CSTF2tau binds many previously not recognized RNAs including histone, snoRNA and snRNAs. CSTF2tau-binding is associated with internal oligoadenylation resulting in shortened snRNA isoforms subjected to rapid degradation. We provide evidence for a new mechanism whereby CSTF2tau controls the abundance of snRNAs resulting in alternative splicing of several RNAs including ANK2 with critical roles in tumorigenesis and cardiac function. Combined with a bioinformatic pipeline sCLIP thus uncovers new functions for established RBPs and fosters the illumination of RBP-protein interaction landscapes in health and disease. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  16. Supplemental knowledge acquisition through external product interface for CLIPS

    Science.gov (United States)

    Saito, Tim; Ebaud, Stephen; Loftin, Bowen R.

    1990-01-01

    Traditionally, the acquisition of knowledge for expert systems consisted of the interview process with the domain or subject matter expert (SME), observation of domain environment, and information gathering and research which constituted a direct form of knowledge acquisition (KA). The knowledge engineer would be responsible for accumulating pertinent information and/or knowledge from the SME(s) for input into the appropriate expert system development tool. The direct KA process may (or may not) have included forms of data or documentation to incorporate from the SME's surroundings. The differentiation between direct KA and supplemental KA (indirect) would be the difference in the use of data. In acquiring supplemental knowledge, the knowledge engineer would access other types of evidence (manuals, documents, data files, spreadsheets, etc.) that would support the reasoning or premises of the SME. When an expert makes a decision in a particular task, one tool that may have been used to justify a recommendation, would have been a spreadsheet total or column figure. Locating specific decision points from that data within the SME's framework would constitute supplemental KA. Data used for a specific purpose in one system or environment would be used as supplemental knowledge for another, specifically a CLIPS project.

  17. Effect of gender on results of percutaneous edge-to-edge mitral valve repair with MitraClip system.

    Science.gov (United States)

    Estévez-Loureiro, Rodrigo; Settergren, Magnus; Winter, Reidar; Jacobsen, Per; Dall'Ara, Gianni; Sondergaard, Lars; Cheung, Gary; Pighi, Michele; Ghione, Matteo; Ihlemann, Nikolaj; Moat, Neil E; Price, Susanna; Streit Rosenberg, Tine; Di Mario, Carlo; Franzen, Olaf

    2015-07-15

    Knowledge regarding gender-specific results of percutaneous edge-to-edge mitral valve repair is scarce. The aim of this study was to investigate gender differences in outcomes in a cohort of patients treated with MitraClip implantation. A multicenter registry of 173 patients treated with MitraClip prostheses from 2009 to 2012 at 3 experienced centers was performed. One hundred nine patients (63%) were men. Men were younger (mean age 73 ± 10 vs 79 ± 9 years, p = 0.001) and had a higher prevalence of previous coronary bypass graft surgery (34% vs 13%, p = 0.002), previous myocardial infarction (46% vs 20%, p = 0.001), and diabetes mellitus (26% vs 11%, p = 0.020). There were no differences regarding New York Heart Association (NYHA) functional class before the intervention (NYHA class III or IV in 95% of men vs 97% of women, p = 0.472) or the cause of mitral regurgitation (MR) (functional in 58% of men vs 48% of women, p = 0.233). Men exhibited significantly larger ventricles (mean indexed left ventricular end-systolic diameter 2.4 ± 0.8 vs 2.0 ± 1.6 cm/m(2), p = 0.002, and mean indexed left ventricular end-diastolic volume 92.7 ± 46.1 vs 59.9 ± 24.6 ml/m(2), p effective treatment of MR in men and women. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Treatment of Traumatic Esophagopleural Fistula Using the Over-the-Scope-Clip System.

    Science.gov (United States)

    Kim, Ji Hyoung; Park, Jong-Jae; Jung, Il Woo; Kim, Sang Hoon; Kim, Hee Dong; Choe, Jung Wan; Joo, Moon Kyung; Kim, Hyun Gu

    2015-09-01

    Esophagopleural fistula (EPF) is a rare condition that is usually accompanied by severe infection and life-threatening morbidity. Here, we report the successful treatment of an EPF by closing an esophageal orifice using the over-the-scope-clip (OTSC) system without postprocedural complications. A 41-year-old man had serious thoracic and abdominal trauma due to a traffic accident. Computed tomography revealed findings suggestive of esophageal rupture due to Boerhaave syndrome. An emergent explorative operation was performed for primary repair with the insertion of a vacuum-assisted closure device. A postoperative upper gastrointestinal series revealed an EPF tract connecting the left pleural space and distal esophagus. We performed an endoscopic procedure using the "traumatic-type"OTSC to seal the EPF, and the esophageal orifice was completely healed 2 weeks postoperatively. The OTSC system might represent a safe and feasible modality for the treatment of EPF.

  19. Angiotensin converting enzyme inhibition induces alterations to hippuran renography despite unchanged ipsilateral renal blood flow in conscious two-kidney, one clip Goldblatt hypertensive dogs

    NARCIS (Netherlands)

    Jonker, G J; de Zeeuw, D; Huisman, R M; van der Hem, G K

    1988-01-01

    We performed experiments in the two-kidney, one clip Goldblatt hypertensive dog to see whether angiotensin converting enzyme (ACE) inhibition could improve the sensitivity of hippurate renography in detecting renal artery stenosis. Ten dogs on a sodium-restricted diet were studied before and after

  20. Clipping de notícias da Escola SENAI Antônio Adolpho Lobbe : proposta para uma biblioteca digital

    OpenAIRE

    Leonardo, Karin-Souza; Zafalon, Zaira-Regina

    2013-01-01

    The technological and scientific scene today shows that there is a lot of information being produced and made available in both the physical environment, as in digital. To be able to offer products and services that involve news published in various media, with pre-established in subjects that meet the informational demands of an organization's interests, it is the use of clipping. The library of SENAI performs this service daily and strives to meet the informational needs of their employees ...

  1. Technological Advances in Joining

    Science.gov (United States)

    1981-08-01

    joint with the progressively advancing laser beam. Surface tension forces support the molten metal and close the keyhole behind the moving be:zm. Deep... keyhole welds in much the same manner as the electron beam which it so closely resembles. Low-power lasers rated at 1000 watts or less are used for...welding, the arc penetrates through the base metal to form the keyhole . Surface tension forces close the keyhole behind the arc as it progresses along

  2. Olfactory groove meningiomas: approaches and complications.

    Science.gov (United States)

    Aguiar, Paulo Henrique Pires de; Tahara, Adriana; Almeida, Antonio Nogueira; Simm, Renata; Silva, Arnaldo Neves da; Maldaun, Marcos Vinicius Calfatt; Panagopoulos, Alexandros Theodoros; Zicarelli, Carlos Alexandre; Silva, Pedro Gabriel

    2009-09-01

    Olfactory groove meningiomas (OGM) account for 4.5% of all intracranial meningiomas. We report 21 patients with OGMs. Tumors were operated on using three surgical approaches: bifrontal (7 patients), fronto-pterional (11 patients) and fronto-orbital (3 patients). Total tumor removal (Simpson Grade 1) was achieved in 13 patients and Simpson II in 8 patients. Perioperative mortality was 4.76%. The average size of the OGM was 4.3+/-1.1cm. The overall recurrence rate was 19%. We preferred to use the pterional approach, which provides quick access to the tumor with less brain exposure. It also allows complete drainage of cisternal cerebrospinal fluid, providing a good level of brain relaxation during surgery. However, for long, thin tumors, hemostasis can be difficult using this approach.

  3. Efficacy and Safety of the Over-the-Scope Clip (OTSC) System in the Management of Leak and Fistula After Laparoscopic Sleeve Gastrectomy: a Systematic Review.

    Science.gov (United States)

    Shoar, Saeed; Poliakin, Lauren; Khorgami, Zhamak; Rubenstein, Rebecca; El-Matbouly, Moamena; Levin, Jun L; Saber, Alan A

    2017-09-01

    Endoscopic management of leaks/fistulas after laparoscopic sleeve gastrectomy (LSG) is gaining popularity in the bariatric surgery. This study aimed to review the efficacy and safety of over-the-scope-clip (OTSC) system in endoscopic closure of post-LSG leak/fistula. PubMed/Medline and major journals of the field were systematically reviewed for studies on endoscopic closure of post-LSG leaks/fistula by means of the OTSC system. A total of ten eligible studies including 195 patients with post-LSG leaks/fistula were identified. The time between LSG and leak/fistula ranged from 1 day to 803 days. Most of the leaks/fistula were located at the proximal staple line, and they sized from 3 to 20 mm. Time between leak diagnosis and OTSC clipping ranged from 0 to 271 days. Thirty-three out of 53 patients (63.5%) required one clip for closure of the lesion. Regarding the OTSC-related complications, a leak occurred in five patients (9.3%) and OTSC migration, stenosis, and tear each in one patient (1.8%). Of the 73 patients with post-LSG leak treated with OTSC, 63 patients had an overall successful closure (86.3%). OTSC system is a promising endoscopic approach for management of post-LSG leaks in appropriately selected patients. Unfortunately, most studies are series with a small sample size, short-term follow-up, and mixed data of concomitant procedures with OTSC. Further studies should distinguish the net efficacy of the OTSC system from other concomitant procedures in treatment of post-LSG leak.

  4. Use of over-the-scope clips (OTSC) for hemostasis in gastrointestinal bleeding in patients under antithrombotic therapy.

    Science.gov (United States)

    Lamberts, Regina; Koch, Anna; Binner, Christian; Zachäus, Marcus; Knigge, Ingrid; Bernhardt, Mark; Halm, Ulrich

    2017-05-01

    Background and study aims  In patients taking different regimens of antithrombotic and/or anticoagulant therapy, endoscopic management of gastrointestinal bleeding represents a major challenge due to failing endogenous hemostasis. In this retrospective study we report on success rates with the over-the-scope clip (OTSC) system in upper and lower gastrointestinal bleeding in this high-risk patient population. Patients and methods  Between February 2011 and June 2014, 75 patients were treated with an OTSC for active gastrointestinal bleeding. Success rates with the first endoscopic therapy, rebleeding episodes, their management and the influence of antithrombotic or anticoagulant therapy were analyzed retrospectively. Results  Application of the OTSC resulted in immediate hemostasis (primary success rate) in all 75 patients. However, in 34.7 % a rebleeding episode was noted that could be treated by further endoscopic interventions. Only 3 patients had to be sent to the operating room because of failure of endoscopic therapy. In the rebleeding group the use of antiplatelet therapies was higher (73.1 % vs. 48.9 %). Conclusions  Application of the OTSC in GI bleeding results in a high rate of primary hemostasis. Rebleeding occurs in up to 35 % of patients receiving antithrombotic/anticoagulant therapy but can be managed successfully with further endoscopic treatments. Patients in the rebleeding group were more frequently treated with antiplatelet agents. Radiological or surgical therapy was reserved for a small subgroup not successfully managed by repeated endoscopic therapies. OTSC application is the treatment of choice in high-risk patients when conventional clips used as first-line treatment fail.

  5. Slow motion in films and video clips: Music influences perceived duration and emotion, autonomic physiological activation and pupillary responses.

    Science.gov (United States)

    Wöllner, Clemens; Hammerschmidt, David; Albrecht, Henning

    2018-01-01

    Slow motion scenes are ubiquitous in screen-based audiovisual media and are typically accompanied by emotional music. The strong effects of slow motion on observers are hypothetically related to heightened emotional states in which time seems to pass more slowly. These states are simulated in films and video clips, and seem to resemble such experiences in daily life. The current study investigated time perception and emotional response to media clips containing decelerated human motion, with or without music using psychometric and psychophysiological testing methods. Participants were presented with slow-motion scenes taken from commercial films, ballet and sports footage, as well as the same scenes converted to real-time. Results reveal that slow-motion scenes, compared to adapted real-time scenes, led to systematic underestimations of duration, lower perceived arousal but higher valence, lower respiration rates and smaller pupillary diameters. The presence of music compared to visual-only presentations strongly affected results in terms of higher accuracy in duration estimates, higher perceived arousal and valence, higher physiological activation and larger pupillary diameters, indicating higher arousal. Video genre affected responses in addition. These findings suggest that perceiving slow motion is not related to states of high arousal, but rather affects cognitive dimensions of perceived time and valence. Music influences these experiences profoundly, thus strengthening the impact of stretched time in audiovisual media.

  6. The Narrative Analysis of the Discourse on Homosexual BDSM Pornograhic Video Clips of The Manhunt Variety

    Directory of Open Access Journals (Sweden)

    Milica Vasić

    2016-02-01

    Full Text Available In this paper we have analyzed the ideal-type model of the story which represents the basic framework of action in Manhunt category pornographic internet video clips, using narrative analysis methods of Claude Bremond. The results have shown that it is possible to apply the theoretical model to elements of visual and mass culture, with certain modifications and taking into account the wider context of the narrative itself. The narrative analysis indicated the significance of researching categories of pornography on the internet, because it leads to a deep analysis of the distribution of power in relations between the categories of heterosexual and homosexual within a virtual environment.

  7. Brain-based decoding of mentally imagined film clips and sounds reveals experience-based information patterns in film professionals.

    Science.gov (United States)

    de Borst, Aline W; Valente, Giancarlo; Jääskeläinen, Iiro P; Tikka, Pia

    2016-04-01

    In the perceptual domain, it has been shown that the human brain is strongly shaped through experience, leading to expertise in highly-skilled professionals. What has remained unclear is whether specialization also shapes brain networks underlying mental imagery. In our fMRI study, we aimed to uncover modality-specific mental imagery specialization of film experts. Using multi-voxel pattern analysis we decoded from brain activity of professional cinematographers and sound designers whether they were imagining sounds or images of particular film clips. In each expert group distinct multi-voxel patterns, specific for the modality of their expertise, were found during classification of imagery modality. These patterns were mainly localized in the occipito-temporal and parietal cortex for cinematographers and in the auditory cortex for sound designers. We also found generalized patterns across perception and imagery that were distinct for the two expert groups: they involved frontal cortex for the cinematographers and temporal cortex for the sound designers. Notably, the mental representations of film clips and sounds of cinematographers contained information that went beyond modality-specificity. We were able to successfully decode the implicit presence of film genre from brain activity during mental imagery in cinematographers. The results extend existing neuroimaging literature on expertise into the domain of mental imagery and show that experience in visual versus auditory imagery can alter the representation of information in modality-specific association cortices. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Classical surgical approach and treatment with clips of extracranial internal carotid artery berry aneurysm

    Directory of Open Access Journals (Sweden)

    Haris Vukas

    2016-06-01

    Full Text Available Introduction: We can define extracranial carotid artery aneurysm (ECAA as bulb dilatation greater than 200% of the diameter of the internal carotid artery (ICA or in a case of common carotid artery (CCA greater than 150% of the diameter. Surgical intervention is required for the treatment of this disease.Case report: This study presents an open vascular surgical procedure to resolve ECAA. We report a case of 61 years old woman with an extracranial internal carotid artery berry aneurysm, presented with a headache and dizziness when turning the head aside. Classic open surgery was performed and the lumen of berry aneurysm was separated with three clips from the lumen of ICA.Conclusions: The open surgical approach is the method of choice for the treatment of extracranial internal carotid artery pathological conditions.

  9. Characteristics and Outcomes of Patients with Anterior Circulation Intracranial Aneurysm Managed with Clipping in Hospital Sungai Buloh.

    Science.gov (United States)

    Ab Ghani, Ailani; Nayan, Saiful Azli Mat; Kandasamy, Regunath; Rosman, Azmin Kas; Ghani, Abdul Rahman Izani

    2016-11-01

    The annual incidence of intracranial aneurysm in Malaysia is estimated to be 1.1-1.7 per 100,000 population based on a study done conducted in 1988. Since then, little epidemiological research has been conducted in Malaysia, and the real incidence is therefore probably unreported despite advancements in the diagnosis and treatment of this disorder. Intracranial aneurysm may be treated by microsurgical clipping or embolisation depending on its location and the surgeon's preference. This study aims to report the characteristics and outcomes of patients with a clipped anterior circulation aneurysm in Hospital Sungai Buloh. We retrospectively collected the data of patients with anterior circulation aneurysms who underwent clipping from 1 January 2013 until 30 June 2014 in Hospital Sungai Buloh. The mean age of the patients was 48.9 years old, and 56.7% of the study population were male and 63.3% were Malay. There were almost equal numbers of patients with (46.7%) and without (53.3%) co-morbidities such as hypertension and ischaemic heart disease. Half of the study population fell under Fisher grade 3 (50.0%), whereas 46.7% were Fisher grade 4. With respect to the Navarro score, 20% of patients scored 10, 16.7% scored 5 or 7, 13.3% scored 11, 10% scored 9, 6.7% scored 1 and 3.3% scored 2, 3 or 8. Most of the patients fell under grade I (33.3%) of the World Federation of Neurological Societies grading (WFNS), and the fewest number of patients were grade III (3.3%). Most (56.7%) patients had an intracranial aneurysm located at the anterior communicating artery (ACOM), followed by the anterior cerebral artery (ACA) and the middle cerebral artery (MCA) (16.7% each), the posterior communicating artery (PCOM) (6.7%) and, finally, the internal carotid artery (ICA) (3.3%). Neurological outcomes at three and six months were assessed using the Modified Rankin Scale (mRS). At three months follow-up, the majority of the participants (33.3%) scored 0 or 6, whereas at six months

  10. S. pombe CLASP needs dynein, not EB1 or CLIP170, to induce microtubule instability and slows polymerization rates at cell tips in a dynein-dependent manner

    Science.gov (United States)

    Grallert, Agnes; Beuter, Christoph; Craven, Rachel A.; Bagley, Steve; Wilks, Deepti; Fleig, Ursula; Hagan, Iain M.

    2006-01-01

    The Schizosaccharomyces pombe CLIP170-associated protein (CLASP) Peg1 was identified in a screen for mutants with spindle formation defects and a screen for molecules that antagonized EB1 function. The conditional peg1.1 mutant enabled us to identify key features of Peg1 function. First, Peg1 was required to form a spindle and astral microtubules, yet destabilized interphase microtubules. Second, Peg1 was required to slow the polymerization rate of interphase microtubules that establish end-on contact with the cortex at cell tips. Third, Peg1 antagonized the action of S. pombe CLIP170 (Tip1) and EB1 (Mal3). Fourth, although Peg1 resembled higher eukaryotic CLASPs by physically associating with both Mal3 and Tip1, neither Tip1 nor Mal3 was required for Peg1 to destabilize interphase microtubules or for it to associate with microtubules. Conversely, neither Mal3 nor Tip1 required Peg1 to associate with microtubules or cell tips. Consistently, while mal3.Δ and tip1.Δ disrupted linear growth, corrupting peg1 + did not. Fifth, peg1.1 phenotypes resembled those arising from deletion of the single heavy or both light chains of fission yeast dynein. Furthermore, all interphase phenotypes arising from peg1 + manipulation relied on dynein function. Thus, the impact of S. pombe CLASP on interphase microtubule behavior is more closely aligned to dynein than EB1 or CLIP170. PMID:16951255

  11. Orbitopterional Craniotomy Resection of Pediatric Suprasellar Craniopharyngioma.

    Science.gov (United States)

    LeFever, Devon; Storey, Chris; Guthikonda, Bharat

    2018-04-01

    The orbitopterional approach provides an excellent combination of basal access and suprasellar access. This approach also allows for less brain retraction when resecting larger suprasellar tumors that are more superiorly projecting due to a more frontal and inferior trajectory. In this operative video, the authors thoroughly detail an orbitopterional craniotomy utilizing a one-piece modified orbitozygomatic technique. This technique involves opening the craniotomy through a standard pterional incision. The craniotomy is performed using the standard three burr holes of a pterional approach; however, the osteotomy is extended anteriorly through the frontal process of the zygomatic bone as well as through the supraorbital rim. In this operative video atlas, the authors illustrate the operative anatomy, as well as surgical strategy and techniques to resect a large suprasellar craniopharyngioma in a 4-year-old male. Other reasonable approach options for a lesion of this size would include a standard pterional approach, a supraorbital approach, or expanded endoscopic transsphenoidal approach. The lesion was quite high and thus, the supraorbital approach may confine access to the superior portion of the tumor. While recognizing that some groups may have chosen the endoscopic expanded transsphenoidal approach for this lesion, the authors describe more confidence in achieving the goal of a safe and maximal resection with the orbitopterional approach. The link to the video can be found at: https://youtu.be/eznsK16BzR8 .

  12. Worst-case residual clipping noise power model for bit loading in LACO-OFDM

    KAUST Repository

    Zhang, Zhenyu; Chaaban, Anas; Shen, Chao; Elgala, Hany; Ng, Tien Khee; Ooi, Boon S.; Alouini, Mohamed-Slim

    2018-01-01

    Layered ACO-OFDM enjoys better spectral efficiency than ACO-OFDM, but its performance is challenged by residual clipping noise (RCN). In this paper, the power of RCN of LACO-OFDM is analyzed and modeled. As RCN is data-dependent, the worst-case situation is considered. A worst-case indicator is defined for relating the power of RCN and the power of noise at the receiver, wherein a linear relation is shown to be a practical approximation. An LACO-OFDM bit-loading experiment is performed to examine the proposed RCN power model for data rates of 6 to 7 Gbps. The experiment's results show that accounting for RCN has two advantages. First, it leads to better bit loading and achieves up to 59% lower overall bit-error rate (BER) than when the RCN is ignored. Second, it balances the BER across layers, which is a desired property from a channel coding perspective.

  13. Fault Diagnosis of Motor Bearing by Analyzing a Video Clip

    Directory of Open Access Journals (Sweden)

    Siliang Lu

    2016-01-01

    Full Text Available Conventional bearing fault diagnosis methods require specialized instruments to acquire signals that can reflect the health condition of the bearing. For instance, an accelerometer is used to acquire vibration signals, whereas an encoder is used to measure motor shaft speed. This study proposes a new method for simplifying the instruments for motor bearing fault diagnosis. Specifically, a video clip recording of a running bearing system is captured using a cellphone that is equipped with a camera and a microphone. The recorded video is subsequently analyzed to obtain the instantaneous frequency of rotation (IFR. The instantaneous fault characteristic frequency (IFCF of the defective bearing is obtained by analyzing the sound signal that is recorded by the microphone. The fault characteristic order is calculated by dividing IFCF by IFR to identify the fault type of the bearing. The effectiveness and robustness of the proposed method are verified by a series of experiments. This study provides a simple, flexible, and effective solution for motor bearing fault diagnosis. Given that the signals are gathered using an affordable and accessible cellphone, the proposed method is proven suitable for diagnosing the health conditions of bearing systems that are located in remote areas where specialized instruments are unavailable or limited.

  14. Interdisciplinarity, Debate And Movie Clips As Highly Motivating Factors In Live Shows - Five Years Of Success

    Science.gov (United States)

    Stengler, E.; Sirera, J. M.

    2011-09-01

    A live show on any subject that includes experiments and continuous interaction with the audience is a well known approach for EPO activities that many are carrying out all over. We present such an initiative with some added ingredients such as interdisciplinarity, the use of movie clips, and especially the debate between the two presenters, a debate that is all the more attractive to the public if it not fully staged but closely represents their actual points of view. José Montesinos, from the "Orotava" Canarian Foundation for the History of Science, is and plays the role of the more mature math professor who has grown weary of the overrated value given in science to mathematics and its consequences. This poses a constant challenge to his colleague, Erik Stengler, from the Science Museum of Tenerife, the young down-to-earth hands-on scientist, who defends the usual view that science and technology are to be judged by their achievements, which have brought about the advancement of modern society. With this approach and as a collaboration between our institutions, we have produced and toured highly successful activities on: Einstein and Relativity (from 2005 to 2008, "Einstein Goes To School," including a theatre play); circularity, the number π, forces of inertia and the Newtonian revolution (in 2008/2009, "The Tension Between Circularity and The Straight Line"); and the foundations of modern astronomy (in 2009/2010 "Kepler and Galileo, Messengers of the Stars"). Audiences were very varied - students, adult students, general public, prison inmates, teachers - and all appreciated the presentations as fun, thought-provoking and highly motivating, and valued especially the interdisciplinary character of the activity. Movie clips have shown to be especially useful to recover the attention of the young when they lose the thread due to the short attention spans they presently have.

  15. One hundred and one over-the-scope-clip applications for severe gastrointestinal bleeding, leaks and fistulas.

    Science.gov (United States)

    Wedi, Edris; Gonzalez, Susana; Menke, Detlev; Kruse, Elena; Matthes, Kai; Hochberger, Juergen

    2016-02-07

    To investigate the efficacy and clinical outcome of patients treated with an over-the-scope-clip (OTSC) system for severe gastrointestinal hemorrhage, perforations and fistulas. From 02-2009 to 10-2012, 84 patients were treated with 101 OTSC clips. 41 patients (48.8%) presented with severe upper-gastrointestinal (GI) bleeding, 3 (3.6%) patients with lower-GI bleeding, 7 patients (8.3%) underwent perforation closure, 18 patients (21.4%) had prevention of secondary perforation, 12 patients (14.3%) had control of secondary bleeding after endoscopic mucosal resection or endoscopic submucosal dissection (ESD) and 3 patients (3.6%) had an intervention on a chronic fistula. In 78/84 patients (92.8%), primary treatment with the OTSC was technically successful. Clinical primary success was achieved in 75/84 patients (89.28%). The overall mortality in the study patients was 11/84 (13.1%) and was seen in patients with life-threatening upper GI hemorrhage. There was no mortality in any other treatment group. In detail OTSC application lead to a clinical success in 35/41 (85.36%) patients with upper GI bleeding and in 3/3 patients with lower GI bleeding. Technical success of perforation closure was 100% while clinical success was seen in 4/7 cases (57.14%) due to attendant circumstances unrelated to the OTSC. Technical and clinic success was achieved in 18/18 (100%) patients for the prevention of bleeding or perforation after endoscopic mucosal resection and ESD and in 3/3 cases of fistula closure. Two application-related complications were seen (2%). This largest single center experience published so far confirms the value of the OTSC for GI emergencies and complications. Further clinical experience will help to identify optimal indications for its targeted and prophylactic use.

  16. The influence of resilient liner and clip attachments for bar-implant-retained mandibular overdentures on opposing maxillary ridge. A 5-year randomised clinical trial.

    Science.gov (United States)

    Elsyad, M A; Ashmawy, T M; Faramawy, A G

    2014-01-01

    This study aimed to compare the influence of resilient liner and clip attachments for bar-implant-retained mandibular overdentures on opposing maxillary ridge after 5 years of denture wearing. Thirty edentulous male patients (mean age 62·5 years) received two implants in the anterior mandible after being allocated into two equal groups using balanced randomisation. After 3 months, implants were connected with resilient bars. New maxillary complete dentures were then constructed, and mandibular overdentures were retained to the bars with either clips (group I, GI) or silicone resilient liners (group II, GII). The prosthetic and soft tissue complications of the maxillary dentures were recorded 6 months (T6 m ), 1 year (T1), 3 years (T3) and 5 years (T5) after overdenture insertion. Traced rotational tomograms were used for measurements of maxillary alveolar bone loss. The proportional value between bone areas and areas of reference not subject to resorption was expressed as a ratio (R). Change in R immediately before (T0) and after 5 years (T5) of overdenture insertion was calculated. Maxillary denture relining times and frequency of flabby anterior maxillary ridge occurred significantly more often in GI compared with GII. The change of R in anterior part of maxilla was significantly higher than change of R in posterior part in both groups. GI showed significant resorption of anterior residual ridge compared with GII. Relining times and frequencies of flabby ridge were significantly correlated with change in R. Within the limitations of this study, resilient liner attachments for bar-implant-retained mandibular overdentures are associated with decreased resorption and flabbiness of maxillary anterior residual ridge and fewer maxillary denture relining times when compared with clip attachments. © 2013 John Wiley & Sons Ltd.

  17. Habitat diversity in the Northeastern Gulf of Mexico: Selected video clips from the Gulfstream Natural Gas Pipeline digital archive

    Science.gov (United States)

    Raabe, Ellen A.; D'Anjou, Robert; Pope, Domonique K.; Robbins, Lisa L.

    2011-01-01

    This project combines underwater video with maps and descriptions to illustrate diverse seafloor habitats from Tampa Bay, Florida, to Mobile Bay, Alabama. A swath of seafloor was surveyed with underwater video to 100 meters (m) water depth in 1999 and 2000 as part of the Gulfstream Natural Gas System Survey. The U.S. Geological Survey (USGS) in St. Petersburg, Florida, in cooperation with Eckerd College and the Florida Department of Environmental Protection (FDEP), produced an archive of analog-to-digital underwater movies. Representative clips of seafloor habitats were selected from hundreds of hours of underwater footage. The locations of video clips were mapped to show the distribution of habitat and habitat transitions. The numerous benthic habitats in the northeastern Gulf of Mexico play a vital role in the region's economy, providing essential resources for tourism, natural gas, recreational water sports (fishing, boating, scuba diving), materials, fresh food, energy, a source of sand for beach renourishment, and more. These submerged natural resources are important to the economy but are often invisible to the general public. This product provides a glimpse of the seafloor with sample underwater video, maps, and habitat descriptions. It was developed to depict the range and location of seafloor habitats in the region but is limited by depth and by the survey track. It should not be viewed as comprehensive, but rather as a point of departure for inquiries and appreciation of marine resources and seafloor habitats. Further information is provided in the Resources section.

  18. Política de indexação para clippings: otimização do tratamento temático em coordenadorias de comunicação social brasileiras

    Directory of Open Access Journals (Sweden)

    Ardala Ponce Kochani

    2012-12-01

    Full Text Available The indexing policy constructed from the objectives and characteristics of each institution optimizes the thematic treatment of information and ensure the quality of both the indexing as a retrieval by subject. Therefore, this study aims to investigate the reality of organizational and communicational of the Coordination of Social Communication of the Federal University of São Carlos (CCS-FUSCar, Brazil, from sociocognitive context of the information professionals and users, for the elaboration of a indexing policy of automated systems of Coordination of Social Communication in brazilian university environments. The results showed that the CCS-FUSC does not have a policy and a guide for the systematize the process of clippings indexing. So, we are suggesting to unit the developing of a policy and of a manual of indexing for clippings by their peculiarities.

  19. Numerical simulation of heat transfer and fluid flow during double-sided laser beam welding of T-joints for aluminum aircraft fuselage panels

    Science.gov (United States)

    Yang, Zhibin; Tao, Wang; Li, Liqun; Chen, Yanbin; Shi, Chunyuan

    2017-06-01

    In comparison with conventional laser beam welding, double-sided laser beam welding has two laser heat sources simultaneously and symmetrically loaded from both sides makes it to be a more complicated coupled heat transport and fluid flow process. In this work, in order to understand the heat transfer and fluid flow, a three-dimensional model was developed and validated with the experimental results. The temperature field, fluid flow field, and keyhole characteristic were calculated using the developed model by FLUENT software. Calculated results indicated that the temperature and fluid flow fields were bilateral symmetry along the stringer center, and the molten pool maximum length was located near the keyhole intersection position. The skin side had higher temperature and faster cooling speed. Several characteristic flow patterns in the weld pool cross section, including the vortexes flows near the keyhole opening position, the convection flows above the keyhole intersection location, the regularity downward flows at the molten pool bottom. And in the lengthwise section, a distinct vortex flow below the keyhole, and the liquid metal behind the keyhole first flowed to near the molten pool maximum length location and then to the molten pool surface. Perpendicular to and along welding direction the keyhole liquid metal flowed to the weld molten pool surface and around the keyhole, respectively. The special temperature fields and fluid flow patterns were closely related to the effects of the double sides' laser energy coupling and enhancement. The calculated weld pool geometry basically in good agreement with the experimental results indicated that the developed model was validity and reasonable.

  20. Rolling the Black Pearl Over: Analyzing the Physics of a Movie Clip

    Science.gov (United States)

    Mungan, Carl E.; Emery, John D.

    2011-05-01

    In the third movie ("At World's End") in the Pirates of the Caribbean series, Jack Sparrow and his crew need to roll their ship (the Black Pearl) over in order to bring it back to the living world during a green flash at sunset. They do so by running back and forth from one side railing to the other on the top deck. In addition, Captain Barbossa orders that 18 cannons and a pile of barrels on the lower deck be cut loose to add mass to the running crew. In the movie they overturned the ship, but would they succeed under the same circumstances on a real galleon? In this paper, a numerical analysis using simple approximations is developed that suggests that what occurs in the movie is in fact realistic. Analyzing a popular film clip in this manner is a good way to arouse student interest, to teach about physics and numerical methods, and to model scientific reasoning when a situation is not as neatly defined as in a typical textbook problem.