WorldWideScience

Sample records for pt test tubes

  1. Development of a TenTorTube for blade tip mechanisms. Pt. 1: feasibility and material tests

    Energy Technology Data Exchange (ETDEWEB)

    Joosse, P.A. [Stork Product Engineering, Amsterdam (Netherlands); Berg, R.M. van der [Rotorline Blade Company, Heerhugowaard (Netherlands)

    1996-12-31

    For variable speed wind turbines it is possible to perform both a power control and a safety function using passive tips. A conventional tip mechanism, consisting of a metal screw cylinder and spring is heavy, expensive and maintenance critical. These problems can be solved with a TenTorTube: a long, slender tube made of composite material in which the anistropic behaviour of fibre reinforced material is used. The feasibility of such a tube made out of fibre reinforced plastic has been shown. To verify the assumptions and obtain reliable material design data static material properties have been measured of epoxy tubes, with different fibre reinforcements. Based on static test values an aramid-epoxy tube showed the highest potential. Following the static tests a torsion creep tests and fatigue tests are carried out with the aim of investigating how this behaviour would influence the feasibility. Present results indicate that an improvement of reliability and reduction of mass and costs of the mechanism is to be expected. (author)

  2. PT and INR Test

    Science.gov (United States)

    Advertisement Proceeds from website advertising help sustain Lab Tests Online. AACC is a not-for-profit organization and does not endorse non-AACC products and services. Advertising & Sponsorship: Policy | Opportunities ...

  3. Results of the Proficiency Test, PT1 and PT2, 2012

    DEFF Research Database (Denmark)

    Vendramin, Niccolò; Nicolajsen, Nicole; Christophersen, Maj-Britt

    A comparative test of diagnostic procedures was provided by the European Union Reference Laboratory (EURL) for Fish Diseases. The test was divided into proficiency test 1 (PT1) and proficiency test 2 (PT2). The number of National Reference Laboratories (NRLs) participating in PT1 and PT2 was 43...

  4. Atmosphere in a Test Tube

    Science.gov (United States)

    Claudi, R.; Pace, E.; Ciaravella, A.; Micela, G.; Piccioni, G.; Billi, D.; Cestelli Guidi, M.; Coccola, L.; Erculiani, M. S.; Fedel, M.; Galletta, G.; Giro, E.; La Rocca, N.; Morosinotto, T.; Poletto, L.; Schierano, D.; Stefani, S.

    The ancestor philosophers' dream of thousand of new world is finally realised: more than 1800 extrasolar planets have been discovered in the neighborhood of our Sun. Most of them are very different from those we used to know in our Solar System. Others orbit the Habitable Zone (HZ) of their parent stars. Space missions, as JWST and the very recently proposed ARIEL, or ground based instruments, like SPHERE@VLT, GPI@GEMINI and EPICS@ELT, have been proposed and built to measure the atmospheric transmission, reflection and emission spectra over a wide wavelength range of these new worlds. In order to interpret the spectra coming out by this new instrumentation, it is important to know in detail the optical characteristics of gases in the typical physical conditions of the planetary atmospheres and how those characteristics could be affected by radiation driven photochemical and bio-chemical reaction. Insights in this direction can be achieved from laboratory studies of simulated planetary atmosphere of different pressure and temperature conditions under the effects of radiation sources, used as proxies of different bands of the stellar emission. ''Atmosphere in a Test Tube'' is a collaboration among several Italian astronomical, biological and engineering institutes in order to share their experiencece in performing laboratory experiments on several items concerning extrasolar planet atmospheres.

  5. Tests of Four PT-415 Coolers Installed in the Drop-in Mode

    Energy Technology Data Exchange (ETDEWEB)

    Green, Michael A.; Wang, S.T.

    2008-07-08

    The superconducting magnets and absorbers for MICE will be cooled using PT415 pulse tube coolers. The cooler 2nd stage will be connected to magnets and the absorbers through a helium or hydrogen re-condensing system. It was proposed that the coolers be connected to the magnets in such a way that the cooler can be easily installed and removed, which permits the magnets to be shipped without the coolers. The drop-in mode requires that the cooler 1st stage be well connected to the magnet shields and leads through a low temperature drop demountable connection. The results of the PT415 drop-in cooler tests are presented.

  6. Testing of Colorimetric Tubes for Nitrogen Dioxide and Monomethylhydrazine.

    Science.gov (United States)

    Diamond, Philip

    Colorimetric tubes for nitrogen dioxide (NO2) and monomethylhydrazine (MMH) were tested for accuracy and results indicate that at the levels checked the tubes' average deviation was plus or minus 20 percent. Tube NO2 concentrations all read lower than the analyzed concentrations. MMH tubes read much higher than the analyzed concentration of 0.28…

  7. Test section configuration for aerodynamic testing in shock tubes

    Science.gov (United States)

    Cook, W. J.; Presley, L. L.; Chapman, G. T.

    1980-01-01

    This paper presents results of a study of the test section configuration required to minimize or alleviate interference effects on model flow produced by the presence of test section walls in the aerodynamic testing of two dimensional transonic airfoils in a shock tube. Tests at a nominal Mach number of 0.85 and a chord Reynolds number of 2,000,000 were carried out by means of schlieren photography and pressure measurements for several symmetric airfoil profiles using shock tube test sections with unmodified straight walls, contoured walls, and slotted walls with adjacent chambers. Results were compared with corresponding results from conventional wind tunnel tests of the airfoils. Results for the straight wall tests show major airfoil flow distortions. Results from contoured wall tests and those performed using a slotted wall test section developed in this study exhibit essential agreement with wind tunnel results. The collective results show that test sections for aerodynamic testing can be designed for shock tubes that will alleviate wall interference effects.

  8. The Crystals Cave in a test tube

    Science.gov (United States)

    Puig, C.; Romero, M. L.

    2012-04-01

    It's quite easy to understand formation of crystals in Nature by evaporation of the solutions that contain minerals, but many times we have realised that our pupils hardly understand that precipitation is a process mostly caused by changing parameters in a solution, like pH, temperature, etc. and not necessarily depending on evaporation. We propose a hands-on activity using the context of the Cave of the Crystals in Naica's mine, Mexico. The Crystals Cave is a wonderful place where giant crystals of selenite (gypsum) have grown feeding from a supersaturated anhydrite solution1. Miners discovered the cave filled with hot water, and drained it to explore the gallery. The cave is now a giant laboratory where scientists are looking for the keys to understand geological processes. Teaching sequence (for students 15 years old) is as follows: DISCOVERING A MARVELLOUS PLACE: We showed our pupils several images and a short video of the Cave of the Crystals and ask them about the process that may have caused the phenomenon. Whole-class discussion. PRESENTING A CHALLENGE TO OUR STUDENTS: "COULD WE CREATE A CRYSTALS CAVE IN A TEST TUBE?" EXPERIMENTING TO IMITATE NATURE: Students tried to grow crystals simulating the same conditions as those in Naica's mine. We have chosen KNO3, a salt more soluble than gypsum. We added 85 g of salt to 200 ml of water (solubility of KNO3 at 25°C is 36 g per 100 gr of water) and heated it until it is dissolved. Afterwards, we poured the solution into some test tubes and other recipients and let them cool at room temperature. And they got a beautiful crystals cave!! THINKING A LITTLE MORE: we asked pupils some questions to make them think about the process and to predict what would happen in different situations. For example: a) What would happen with crystals if we heated the tubes again? or b) What would happen if we took the remaining solution from the tubes and keep it in the fridge? PROVING A NEW HYPOTHESIS: Pupils collected the remaining

  9. Fabrication of Test Tubes for Coal Ash Corrosion Testing

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R.; Judkins, R.R.; Sikka, V.K.; Swindeman, R.W.; Wright, I.G.

    1999-05-11

    This paper deals with the fabrication of tube sections of four alloys for incorporating into test sections to be assembled by Babcock & Wilcox (B&W) for installation at Ohio Edison Power, Niles Plant. The primary purpose of the installation was to determine the corrosion behavior of ten different alloys for flue gas corrosion. Ohio Edison Power, Niles Plant is burning an Ohio coal containing approximately 3.4% S (dry basis) and approximately 0.4% alkali which causes chronic coal ash corrosion of the unit�s superheater tubing. The 2.5-in.-OD x 0.4in.-wall x 6-in-long sections of four alloys {type 304H coated with Fe3Al alloy FAS [developed at the Oak Ridge National Laboratory (ORNL)], 310 + Ta, modified 800H, and Thermie alloy} were fabricated at ORNL. Each alloy tubing was characterized in terms of chemical analysis and microstructure. The machined tubes of each of the alloys were inspected and shipped on time for incorporation into the test loop fabricated at B&W. Among the alloys fabricated, Thermie was the hardest to extrude and machine.

  10. Template synthesized chitosan nano test tubes for drug delivery applications

    Science.gov (United States)

    Perry, Jillian L. Moulton

    There is tremendous current interest in developing nanoscale drug delivery vehicles. Though intensive efforts have focused on developing spherical drug delivery vehicles, cylindrically shaped vehicles such as nanotubes offer many advantages. Typically, nanotubes can carry a larger inner payload than nanoparticles of the same diameter. Also, we can prepare nanotubes in templates whose geometries can be controlled, in turn allowing precise control over the length and diameter of the tubes. In addition, template synthesized nanotubes can be differentially functionalized on the inner and outer surfaces. Furthermore, templates that are closed on one end can be used to fabricate nano test tubes (closed on one end). The geometry of these nano test tubes allows them to be easily filled with a payload, the open end sealed with a nanoparticle to protect the payload from leaking out, and then the exterior of the tube can be functionalized with a targeting moiety. In an effort to develop such a system, we explored the fabrication of chitosan nano test tubes. Defect-free, chitosan nano test tubes of uniform size were synthesized within the pores of a nanoporous alumina template membrane. While the nano test tubes remained within the template membrane, their inner cavities were filled with a model payload. The payload was then trapped inside the nano test tubes by sealing the open ends of the tubes with latex nanoparticle caps. For proof-of-principle studies, imine linkages were used to attach the caps to the nano test tubes. To create a self-disassembling system, disulfide chemistry was used to covalently cap the nano test tubes. Once removed from the template, the exterior of the nano test tubes were modified with a targeting moiety, allowing them to be targeted to pathological sites. We have also shown that the chitosan nano test tubes are biodegradable by two systems: enzymatic cleavage by lysozymes and disulfide cleavage of the crosslinker by reducing environments

  11. Testing of a 7-tube palladium membrane reactor for potential use in TEP

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, Bryan J [Los Alamos National Laboratory; Trujillo, Stephen [Los Alamos National Laboratory; Willms, R. Scott [Los Alamos National Laboratory

    2010-01-01

    A Palladium Membrane Reactor (PMR) consists of a palladium/silver membrane permeator filled with catalyst (catalyst may be inside or outside the membrane tubes). The PMR is designed to recover tritium from the methane, water, and other impurities present in fusion reactor effluent. A key feature of a PMR is that the total hydrogen isotope content of a stream is significantly reduced as (1) methane-steam reforming and/or water-gas shift reactions proceed on the catalyst bed and (2) hydrogen isotopes are removed via permeation through the membrane. With a PMR design matched to processing requirements, nearly complete hydrogen isotope removals can be achieved. A 3-tube PMR study was recently completed. From the results presented in this study, it was possible to conclude that a PMR is appropriate for TEP, perforated metal tube protectors function well, platinum on aluminum (PtA) catalyst performs the best, conditioning with air is probably required to properly condition the Pd/Ag tubes, and that CO/CO{sub 2} ratios maybe an indicator of coking. The 3-tube PMR had a permeator membrane area of 0.0247 m{sup 2} and a catalyst volume to membrane area ratio of 4.63 cc/cm{sup 2} (with the catalyst on the outside of the membrane tubes and the catalyst only covering the membrane tube length). A PMR for TEP will require a larger membrane area (perhaps 0.35 m{sup 2}). With this in mind, an intermediate sized PMR was constructed. This PMR has 7 permeator tubes and a total membrane area of 0.0851 m{sup 2}. The catalyst volume to membrane area ratio for the 7-tube PMR was 5.18 cc/cm{sup 2}. The total membrane area of the 7-tube PMR (0.0851 m{sup 2}) is 3.45 times larger than total membrane area of the 3-tube PMR (0.0247 m{sup 2}). The following objectives were identified for the 7-tube PMR tests: (1) Refine test measurements, especially humidity and flow; (2) Refine maintenance procedures for Pd/Ag tube conditioning; (3) Evaluate baseline PMR operating conditions; (4) Determine PMR

  12. Design of water shock tube for testing shell materials

    OpenAIRE

    Ji, Hongjuan; Mustafa, Mohamad; Khawaja, Hassan Abbas; Ewan, Bruce C.; Moatamedi, Mojtaba

    2014-01-01

    This paper presents design considerations for a shock tube experimental rig used to investigate the dynamic failure mechanisms of shell geometries subjected to water shock impact loading. In such setup, it is desirable that the drive pressure used within the tube can provide a wide range of impulsive loads on the test structures and some flexibility can be achieved on the applied pulse durations. With this aim a review of various existing shock tube experimental setup is presented and choi...

  13. Characterization of Friction Stir Welded Tubes by Means of Tube Bulge Test

    Science.gov (United States)

    D'Urso, G.; Longo, M.; Giardini, C.

    2011-05-01

    Mechanical properties of friction stir welded joints are generally evaluated by means of conventional tensile test. This testing method might provide insufficient information because maximum strain obtained in tensile test before necking is small; moreover, the application of tensile test is limited when the joint path is not linear or even when the welds are executed on curved surfaces. Therefore, in some cases, it would be preferable to obtain the joints properties from other testing methods. Tube bulge test can be a valid solution for testing circumferential or longitudinal welds executed on tubular workpieces. The present work investigates the mechanical properties and the formability of friction stir welded tubes by means of tube bulge tests. The experimental campaign was performed on tubular specimens having a thickness of 3 mm and an external diameter of 40 mm, obtained starting from two semi-tubes longitudinally friction stir welded. The first step, regarding the fabrication of tubes, was performed combining a conventional forming process and friction stir welding. Sheets in Al-Mg-Si-Cu alloy AA6060 T6 were adopted for this purpose. Plates having a dimension of 225×60 mm were bent (with a bending axis parallel to the main dimension) in order to obtain semi-tubes. A particular care was devoted to the fabrication of forming devices (punch and die) in order to minimize the springback effects. Semi-tubes were then friction stir welded by means of a CNC machine tool. Some preliminary tests were carried out by varying the welding parameters, namely feed rate and rotational speed. A very simple tool having flat shoulder and cylindrical pin was used. The second step of the research was based on testing the welded tubes by means of tube bulge test. A specific equipment having axial actuators with a conical shape was adopted for this study. Some analyses were carried out on the tubes bulged up to a certain pressure level. In particular, the burst pressure and the

  14. The Simulation and Test for Piezoelectric Composite Tube

    Directory of Open Access Journals (Sweden)

    Wang Hongwei

    2016-01-01

    Full Text Available Piezoelectric composite circular tube has been developed,this tube is used for underwater acoustic transducer. The finite element simulation has been done for piezoelectric composite material tube, and gained the tube structure parameters. In accordance with the structural parameters obtained from the simulation, the composite circular tube is processed and its performance has been tested. the results show as follow: Acoustic impedance is 18.05 (Pa·s/m3, relative permittivity is 859, sound velocity is 3200m/s, d33 constant is 480 pC/N, vibration displacement is 89.5pm, the resonant frequency is 388kHz, bandwidth is 11.2kHz,. The piezoelectric composite circular tubes suitable for horizontal omnidirectional broadband transducer.

  15. 42 CFR 84.152 - Breathing tube test; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... Respirators § 84.152 Breathing tube test; minimum requirements. (a)(1) Type A and Type B supplied-air respirators shall employ one or two flexible breathing tubes of the nonkinking type which extend from the... employed on Type C supplied-air respirators of the continuous flow class shall meet the...

  16. Investigation into the suitability of capillary tubes for microcrystalline testing.

    Science.gov (United States)

    Elie, Leonie E; Baron, Mark G; Croxton, Ruth S; Elie, Mathieu P

    2013-07-01

    A comparison between microcrystalline tests performed on microscope slides and flat capillary tubes with inner diameters ranging from 0.1 to 0.7 mm was carried out to explore the appropriateness of tubes for rapid testing of suspected drugs of abuse in the laboratory as well as in the field. Tests for mephedrone, cocaine, and phencyclidine were chosen as examples to investigate the handling of the capillary tubes, the influence on crystal habit, size, and the effects on the limit of detection. Image stacking software was used to increase the depth of field of micrographs taken from developed microcrystals greatly enhancing the interpretability even months after carrying out the microcrystalline test. Additionally, the potential of seeding capillary tubes with a reagent was studied. Pre-treatment of tubes would allow microcrystalline tests to be carried out quicker and anywhere without the necessity of taking along expensive and hazardous reagents. The sealing of capillary tubes containing developed microcrystalline tests in order to preserve results for a long period of time was successfully done by applying paraffin wax to the open ends. Finally, it was concluded that capillary tubes are suitable vessels for performing microcrystalline tests. The increased portability of the improved set-up allows tests to be safely executed outside laboratories without impairing the quality of the result. Findings were applied to six legal high samples purchased online between May and August 2011. The active ingredients like MDAI as well as cutting agents like caffeine were successfully identified using the microcrystalline test technique in capillary tubes.

  17. Indoor tests of the concentric-tube solar collector

    Science.gov (United States)

    1980-01-01

    Report describes performance tests on 12-tube, liquid-filled collector. Thermal efficiency, change in efficiency with sun position, and time constant for temperature drop after solar flux is cut are described.

  18. Design, production and testing of PMN-PT electrostrictive transducers.

    Science.gov (United States)

    Coutte, J; Dubus, B; Debus, J C; Granger, C; Jones, D

    2002-05-01

    Lead magnesium niobate ceramics (PMN) are promising materials for application in the field of high power transducers. The advantage of PMN materials are the large strains generated under moderate electric field and the low hysteresis. The electrostrictive effect is non-linear, the corresponding physical constants depend on temperature and frequency and a DC electrical bias is required. These difficulties must be considered at the design stage. A finite element model has been developed and validated in the ATILA code for non-linear static and time-domain analyses. These numerical modelings are used to design and test two Langevin-type electrostrictive transducers. The first transducer is made of PMN-PT-La (90-10-1%) ceramics (TRS Ceramics), the second one of ESCI ceramics (Morgan Matroc). For given static mechanical prestresses, resonance frequencies and effective coupling coefficients are measured at different DC electric fields and temperatures.

  19. Testing and analysis of tube voltage and tube current in the radiation generator for mammography

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hong Ryang; Hong, Dong Hee [Dept. of Health Care, Hanseo University, Seosan (Korea, Republic of); Han, Beom Hui [Dept. of Radiological Science, Seonam University, Namwon (Korea, Republic of)

    2014-03-15

    Breast shooting performance management and quality control of the generator is applied to the amount of current IEC(International Electrotechnical Commission) 60601-2-45 tube voltage and tube current are based on standards that were proposed in the analysis of the test results were as follows. Tube voltage according to the value of the standard deviation by year of manufacture from 2001 to 2010 as a 42-3.15 showed the most significant, according to the year of manufacture by tube amperage value of the standard deviation to 6.38 in the pre-2000 showed the most significant , manufactured after 2011 the standard deviation of the devices, the PAE(Percent Average Error) was relatively low. This latest generation device was manufactured in the breast of the tube voltage and tube diagnosed shooting the correct amount of current to maintain the performance that can be seen. The results of this study as the basis for radiography diagnosed breast caused by using the device's performance and maintain quality control, so the current Food and Drug Administration 'about the safety of diagnostic radiation generator rule' specified in the test cycle during three years of self-inspection radiation on a radiation generating device ensure safety and performance of the device using a coherent X-ray(constancy) by two ultimately able to keep the radiation dose to the public to reduce the expected effect is expected.

  20. Zirconium pressure tube testing: Test procedures, Production Assurance Program (Project H-700)

    Energy Technology Data Exchange (ETDEWEB)

    Zaloudek, F.R.; Lewis, M. [Pacific Northwest Lab., Richland, WA (United States)

    1986-06-01

    UNC Nuclear Industries (UNC) has initiated a plan for the fabrication of zirconium alloy pressure tubes required for the future operation of N-Reactor. As part of this plan, UNC is establishing a program to qualify and develop a process capable of fabricating these pressure tubes to the requirements of UNC specification HWS 6502, REV. 4, Amendment 1. The objective of the Pressure Tube Testing Task is to support the UNC program-by performing physical, mechanical and chemical testing on prototype tube sections produced during FY-1986, 1987 and 1988 and to test samples from production runs after 1988 as may be required. The types of tests included in the Zirconium Pressure Tube Testing Program will be as follows: tensile tests; burst tests; fracture toughness tests; corrosion tests; chemical composition analyses; grain structure evaluations. The purpose of this document is to define the procedures that will be used in each type of test included in this task.

  1. Mechanical testing of anisotropy in ODS steel tubes

    Science.gov (United States)

    Špirit, Z.; Chocholoušek, M.; Šíma, M.

    2017-02-01

    Anisotropy of fuel claddings made from Fe-9Cr and Fe-14Cr ODS (oxide dispersion-strengthened) steel for Generation IV reactors with coolants based on liquid metals was examined. Basic mechanical tests were performed at temperatures of 30 °C, 500 °C and 625 °C on ODS steel thin-walled tubes. Tensile tests were performed in axial and tangential directions in a vacuum to avoid oxidation of the small specimens. A scanning electron microscope with a small in-situ tensile testing device was used to conduct the tests. The result of this paper describes the basic mechanical properties of thin-walled tubes as ultimate tensile strength, yield strength, tensile modulus, etc. depending on the direction of loading.

  2. The pilot test of Pt-Pd and Pt-Rh feeds extracted and separated with a new sulfoxide extractant

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Platinum, palladium and rhodium of the raw feeds extracted and separated with a new sulfoxide extractant (MSO)were studied in the paper. The pilot test results showed that the percentage extractions are more than 99% for platinum and palladium in Pt-Pd feed, and the percentage strippings are 100% and 99.2% with HCl and ammonia, respectively. The ratio of palladium to platinum is 0.0016 in stripping platinum solution, and the ratio of platinum to palladium is 0.0020 in stripping palladium solution. The percentage extraction of platinum is 99% in Pt-Rh feed, and the percentage stripping is 100%.The ratio of rhodium to platinum is 0.0002 in stripping platinum solution. Therefore, platinum, palladium, and rhodium feeds are separated effectively with MSO.

  3. RIA simulation tests using driver tube for ATF cladding

    Energy Technology Data Exchange (ETDEWEB)

    Cinbiz, Mahmut N. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Brown, N. R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Lowden, R. R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Linton, K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Terrani, K. A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-07-01

    Pellet-cladding mechanical interaction (PCMI) is a potential failure mechanism for accident-tolerant fuel (ATF) cladding candidates during a reactivity-initiated accident (RIA). This report summarizes Fiscal Year (FY) 2017 research activities that were undertaken to evaluate the PCMI-like hoop-strain-driven mechanical response of ATF cladding candidates. To achieve various RIA-like conditions, a modified-burst test (MBT) device was developed to produce different mechanical pulses. The calibration of the MBT instrument was accomplished by performing mechanical tests on unirradiated Generation-I iron-chromium-aluminum (FeCrAl) alloy samples. Shakedown tests were also conducted in both FY 2016 and FY 2017 using unirradiated hydrided ZIRLO™ tube samples. This milestone report focuses on testing of ATF materials, but the benchmark tests with hydrided ZIRLO™ tube samples are documented in a recent journal article.a For the calibration and benchmark tests, the hoop strain was monitored using strain gauges attached to the sample surface in the hoop direction. A novel digital image correlation (DIC) system composed of a single high-speed camera and an array of six mirrors was developed for the MBT instrument to better resolve the failure behavior of samples and to provide useful data for validation of high-fidelity modeling and simulation tools. The DIC system enable a 360° view of a sample’s outer surface. This feature was added to the instrument to determine the precise failure location on a sample’s surface for strain predictions. The DIC system was tested on several silicon carbide fiber/silicon carbide matrix (SiC/SiC) composite tube samples at various pressurization rates of the driver tube (which correspond to the strain rates for the samples). The hoop strains for various loading conditions were determined for the SiC/SiC composite tube samples. Future work is planned to enhance understanding of the failure behavior of the ATF cladding candidates of age

  4. Results of the Proficiency Test, PT1 and PT2, 2011

    DEFF Research Database (Denmark)

    Kahns, Søren; Nicolajsen, Nicole; Christophersen, Maj-Britt

    2012-01-01

    A comparative test of diagnostic procedures was provided by the EU Reference Laboratory (EURL) for Fish Diseases to 41 National Reference Laboratories (NRLs) in the start of middle of October 2011. The test was prepared and tested according to protocols accredited by DANAK under registration number...

  5. Field tests of 2- and 40-tube condensers at the East Mesa Geothermal Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, R.W.; Domingo, N.

    1982-05-01

    Two water-cooled isobutane condensers, one with 2 tubes and one with 40 tubes, were subjected to field tests at the East Mesa Geothermal Test Site to assess relative heat transfer performance in both surface evaporator and direct-contact evaporator modes. The five groups of tests established that field performance was below earlier laboratory-determined levels and that direct-contact evaporator mode performance was poorer than that for the surface evaporator mode. In all test situations, fluted condenser tubes performed better than smooth condenser tubes. Cooling water quality had no significant effect on performance, but brine preflash in the direct-contact mode did promote some relative performance improvement. Important implications of these results for binary geothermal power plants are that (1) working-fluid-side impurities can significantly degrade heat transfer performance of the power plant condensers and (2) provisions for minimizing such impurities may be required.

  6. Design, development and testing twin pulse tube cryocooler

    Science.gov (United States)

    Gour, Abhay Singh; Sagar, Pankaj; Karunanithi, R.

    2017-09-01

    The design and development of Twin Pulse Tube Cryocooler (TPTC) is presented. Both the coolers are driven by a single Linear Moving Magnet Synchronous Motor (LMMSM) with piston heads at both ends of the mover shaft. Magnetostatic analysis for flux line distribution was carried-out during design and development of LMMSM based pressure wave generator. Based on the performance of PWG, design of TPTC was carried out using Sage and Computational Fluid Dynamics (CFD) analysis. Detailed design, fabrication and testing of LMMSM, TPTC and their integration tests are presented in this paper.

  7. A study of test section configuration for shock tube testing of transonic airfoils

    Science.gov (United States)

    Cook, W. J.

    1978-01-01

    Two methods are investigated for alleviating wall interference effects in a shock tube test section intended for testing two-dimensional transonic airfoils. The first method involves contouring the test section walls to match approximate streamlines in the flow. Contours are matched to each airfoil tested to produce results close to those obtained in a conventional wind tunnel. Data from a previous study and the present study for two different airfoils demonstrate that useful results are obtained in a shock tube using a test section with contoured walls. The second method involves use of a fixed-geometry slotted-wall test section to provide automatic flow compensation for various airfoils. The slotted-wall test section developed exhibited the desired performance characteristics in the approximate Mach number range 0.82 to 0.89, as evidenced by good agreement obtained between shock tube and wind tunnel results for several airfoil flows.

  8. Template synthesis of test tube nanoparticles using non-destructive replication.

    Science.gov (United States)

    Wagner, Jonathan; Yao, Jingyuan; Rodgers, David; Hinds, Bruce

    2013-03-01

    Nano test tubes are a promising delivery vehicle for a range of therapeutics, including small molecule drugs and biologics. However, current template synthesis methods of producing nano test tubes are prohibitively expensive and time consuming. Here, non-destructive template replication was used to increase nano test tube yield from porous alumina by more than a hundredfold. We demonstrate how to produce nano test tubes of several sizes and compositions, including hybrid tubes with different inner and outer surfaces for targeted surface chemistry. Nano test tubes were readily suspended and stored in aqueous solutions without the need for chemical treatment. These nano test tubes should find application as delivery vehicles for therapeutics, particularly for processive 'bionanoreactors' loaded with enzymes.

  9. Further Tests of the CMS Drift Tubes Muon Trigger

    CERN Document Server

    Aldaya, M; Battilana, Carlo; Bellato, Marco; Benvenuti, Alberto; Bontenackels, Michael; Castellani, Lorenzo; Cavallo, Francesca Romana; Cerminara, Gianluca; Checchia, Paolo; Conti, Enrico; Dallavalle, Gaetano-Marco; de la Cruz, Begona; Deldicque, Christian; Ero, J; Fernández, C; Fernández de Troconiz, J; Fouz-Iglesias, M C; Gasparini, Fabrizio; Giacomelli, Paolo; Giunta, Marina; Gonella, Franco; Guiducci, Luigi; Hebbeker, Thomas; Höpfner, K; Jimenez, Ignacio; Josa-Mutuberria, I; Lacaprara, Stefano; Marcellini, Stefano; Maron, Gaetano; Meneguzzo, Anna Teresa; Monaco, Vincenzo; Montanari, Alessandro; Navarria, Francesco; Odorici, Fabrizio; Parenti, Andrea; Passaseo, Marina; Perrotta, Andrea; Puerta, J; Reithler, Hans; Ronchese, Paolo; Rovelli, Tiziano; Ruetten, P; Sowa, Michael; Staiano, Amedeo; Toniolo, Nicola; Torassa, Ezio; Torromeo, Giovanni; Travaglini, Riccardo; Vanini, Sara; Ventura, Sandro; Villanueva, C; Zanetti, Marco; Zotto, Pierluigi

    2006-01-01

    Two drift tubes stations of the CMS muon barrel system were exposed, in October 2004, to a 40 MHz bunched muon beam at the Cern SpS. The performances of the level-1 local trigger were tested at different energies and inclination angles of the incident muon beam. Data with and without an iron absorber placed between the two stations were also collected, to simulate the electromagnetic shower development in CMS. In addition special data-taking runs were dedicated to test for the first time the level-1 Track Finder trigger system. The present note describes the results of such measurements, focusing the attention on the efficiency and the noise rate of the trigger systems.

  10. Environmental test report for the WX-32335 SEC camera tube. [for International Ultraviolet Explorer

    Science.gov (United States)

    Malanoski, R. J.

    1973-01-01

    The environmental testing activity on the WX-32335 was carried out to determine if this tube type could withstand the environmental requirements established for the International Ultraviolet Explorer (IUE) camera tube (WX-32224). The results of the tests led to the following conclusions: (1) The WX-32335 as processed with a CsTe photocathode surface can withstand the temperature extremes established for the IUE camera tube without damage to the photocathode surface or without introducing background signal in the tube after one hour of dark integration. (2) The WX-32335 built with a WX-32224 type target support structure can withstand the sinusoidal vibration requirements established for the IUE camera tube. (3) Although the vibration test of the WX-32335 type tubes built with the flat target ring structure could not be completed, there was no indication that these tubes could not withstand the sinusoidal vibration requirements established for the IUE camera tube.

  11. [Selection of suitable polypropylene tubes for DNA testing using real-time PCR].

    Science.gov (United States)

    Shimizu, Eri; Futo, Satoshi; Masubuchi, Tomoko; Minegishi, Yasutaka; Kasahara, Masaki; Akiyama, Hiroshi; Teshima, Reiko; Hino, Akihiro; Mano, Jyunichi; Furui, Satoshi; Kitta, Kazumi

    2010-01-01

    Polypropylene microtubes (tubes) are generally used for bio-material tests in addition to PCR tests such as genetically modified organism (GMO) testings. However, the choice of suitable tubes is quite important, because it might influence the results: DNA binding and/or elution of chemical substances sometimes occurs. In this study, we established methods to select tubes with the most suitable characteristics for DNA testing.

  12. DNA nanotechnology from the test tube to the cell.

    Science.gov (United States)

    Chen, Yuan-Jyue; Groves, Benjamin; Muscat, Richard A; Seelig, Georg

    2015-09-01

    The programmability of Watson-Crick base pairing, combined with a decrease in the cost of synthesis, has made DNA a widely used material for the assembly of molecular structures and dynamic molecular devices. Working in cell-free settings, researchers in DNA nanotechnology have been able to scale up system complexity and quantitatively characterize reaction mechanisms to an extent that is infeasible for engineered gene circuits or other cell-based technologies. However, the most intriguing applications of DNA nanotechnology - applications that best take advantage of the small size, biocompatibility and programmability of DNA-based systems - lie at the interface with biology. Here, we review recent progress in the transition of DNA nanotechnology from the test tube to the cell. We highlight key successes in the development of DNA-based imaging probes, prototypes of smart therapeutics and drug delivery systems, and explore the future challenges and opportunities for cellular DNA nanotechnology.

  13. Testing of Photomultiplier Tubes in a Magnetic Field

    Science.gov (United States)

    Waldron, Zachary; A1 Collaboration

    2016-09-01

    The A1 collaboration at MAMI in Mainz, Germany has designed a neutron detector that can be used in experiments to measure the electric form factor of the neutron. They will measure elastic scattering from the neutron, using the polarized electron beam from MAMI at A1's experimental hall. The detector will be composed of two walls of staggered scintillator bars which will be read out by photomultiplier tubes (PMT), connected to both ends of each scintillator via light guides. The experiment requires a magnetic field with strength of 1 Tesla, 2m away from the first scintillator wall. The resulting fringe field is sufficient to disrupt the PMTs, despite the addition of Mu Metal shielding. The effects of the fringe field on these PMTs was tested to optimize the amplification of the PMTs. A Helmholtz Coil was designed to generate a controlled magnetic field with equivalent strength to the field that the PMTs will encounter. The PMTs were read out using a multi-channel analyzer, were tested at various angles relative to the magnetic field in order to determine the optimal orientation to minimize signal disruption. Tests were also performed to determine: the neutron detector response to cosmic radiation; and the best method for measuring a magnetic field's strength in two dimensions. National Science Foundation Grant No. IIA-1358175.

  14. Simulation of Cracks Detection in Tubes by Eddy Current Testing

    Directory of Open Access Journals (Sweden)

    S Bennoud

    2016-12-01

    Full Text Available The eddy current testing can be used such as a perfect tool to characterize defects in conducting materials. However, in the latest years, an important progress was made in the development of software for the eddy current testing simulations. Evaluation of the NDT modeling tools is the principal goal of this study. Main concerns of the aeronautic industry and the potential contribution of modeling are discussed and illustrated. Simulation by finite element method is realized with the aim to calculate the electromagnetic energy of interaction between coil and tested part that enables to deduce the impedance response. The objective of this work is the development of a code for efficient resolution of an electromagnetic problem modeling, especially, for the analysis of probe response due to the eddy current process. The validation of developed code was made. The obtained results converge quickly towards the solution given by the (FEMM code with an average error of 0.018 for real parts of impedance and 0.004 for imaginary parts. The presented results in this work serve to illustrate that the proposed method is practical and they are also of some intrinsic interest especially in the control of aluminum tubes used in aeronautics.

  15. Changes of structure and crystallographic texture of cladding tubes from austenitic steel under thermal creep testing

    Science.gov (United States)

    Perlovich, Yu; Isaenkova, M.; Fesenko, V.; Dobrokhotov, P.; Tselishchev, A.

    2016-04-01

    The process of changes in structure and crystallographic texture of cladding tubes from austenitic steel ChS68 under thermal creep testing were studied. Testing of tubes was conducted at the temperature 700 oC in the air by their stretching in axial direction under the stress 160 MPa until rupture. By data of phase and texture analysis a number of processes, accompanying plastic deformation of tubes during thermal creep tests at elevated temperature, were identified. The main texture components of original tube, as well as texture components of different parts of the tested tube are {110} and {112}. In the rupture zone the component of the texture of tension with axis along the tube axis becomes stronger. This effect is connected with activation of dislocation slip in the deformed area of tested tube near the new-formed neck. At the same time the character of texture changes in the zone of tube rupture indicates to development of the dynamic recrystallization, conditioned by the total influence of all factors, which control the passage in the tube of thermal creep. In addition, it was revealed the activation of martensitic transformations in the zone of maximal deformation of tube as a result of its creep tests.

  16. Using synthetic biology to make cells tomorrow's test tubes.

    Science.gov (United States)

    Garcia, Hernan G; Brewster, Robert C; Phillips, Rob

    2016-04-18

    The main tenet of physical biology is that biological phenomena can be subject to the same quantitative and predictive understanding that physics has afforded in the context of inanimate matter. However, the inherent complexity of many of these biological processes often leads to the derivation of complex theoretical descriptions containing a plethora of unknown parameters. Such complex descriptions pose a conceptual challenge to the establishment of a solid basis for predictive biology. In this article, we present various exciting examples of how synthetic biology can be used to simplify biological systems and distill these phenomena down to their essential features as a means to enable their theoretical description. Here, synthetic biology goes beyond previous efforts to engineer nature and becomes a tool to bend nature to understand it. We discuss various recent and classic experiments featuring applications of this synthetic approach to the elucidation of problems ranging from bacteriophage infection, to transcriptional regulation in bacteria and in developing embryos, to evolution. In all of these examples, synthetic biology provides the opportunity to turn cells into the equivalent of a test tube, where biological phenomena can be reconstituted and our theoretical understanding put to test with the same ease that these same phenomena can be studied in the in vitro setting.

  17. Indoor test for thermal performance evaluation of seven Elcam fin-tube solar collector configurations

    Science.gov (United States)

    1979-01-01

    The test procedure used and the results obtained from an evaluation test program conducted to obtain thermal performance data on seven Elcam fin-tube solar collector configurations under simulated conditions are described. These tests were made using the Marshall Space Flight Center solar facilities. The Elcam fin-tube (liquid) solar collectors each consist of an absorber plate 5.9 inches wide by 83 inches long and a type M copper tube of 0.569 inch nominal inside diameter. No cover plate was used with any of the specimens. The uniqueness of each of the seven configurations is described, and tests were performed on each separate configuration.

  18. Deformation Characterization of Friction-Stir-Welded Tubes by Hydraulic Bulge Testing

    Science.gov (United States)

    Pang, Q.; Hu, Z. L.; Pan, X.; Zuo, X. Q.

    2014-10-01

    In this article, the large-diameter thin-walled aluminum alloy tubes were produced using a hybrid process combining friction-stir welding (FSW) and spinning. For this novel process, rolled aluminum alloy sheets with a thickness about 2-3 times the wall thickness of target tube, were FSW to form cylinders, and then the cylinders were subjected to spinning to get thin-walled aluminum alloy tubes. Both experimental and simulation study were conducted to investigate the deformation characterization of the FSW tube during hydraulic bulge testing, and the stress and strain states and thickness distribution of the FSW tube were investigated. It was found that the common defects of FSW tube can be significantly improved by specific welding devices. The ductility of the tube is considerably improved with nearly two times higher bulge ratio than as-spun tube after annealing treatment at 300°C. But the annealed tube still shows a high nonuniform wall thickness distribution due to the inhomogeneous deformation characteristics. With increasing deformation of the tube, the gap between the hoop and axial stress for the weld and base metal (BM) decreases. However, the hoop and axial stress of the weld are always greater than those of the BM at the same pressure.

  19. Leak rate and burst test data for McGuire Unit 1 steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Sherburne, P.A. [B& W Nuclear Service Co., Lynchburg, VA (United States); Frye, C.R. [Babcock & Wilcox Co., Lynchburg, VA (United States); Mayes, D.B. [Duke Power Co., Charlotte, NC (United States)

    1992-12-31

    To support the development of tube plugging criteria that would allow tubes with through-wall cracks to remain in service, sections of 12 tubes were removed from the McGuire Unit-1 steam generators. These tubes were sent to B&W Nuclear Service Company for metallographic examination and for determination of burst pressure and leak rate at both operating and faulted conditions. Primary water stress corrosion cracking (PWSCC) had degraded these tubes in the tube-to-tubesheet roll transitions. To measure primary-to-secondary leakage at pressures and temperatures equivalent to those in the McGuire Unit-1 steam generators, an autoclave-based test loop was designed and installed at the Babcock & Wilcox Lynchburg Research Center. Sections of the tube containing the roll transitions were then installed in the autoclave and actual primary- to-secondary leakage was measured at 288{degrees}C (550{degrees}F) and at 9 and 18.3 MPa (1300 and 2650 psi) pressure differentials. Following the leak test, the tubes were pressurized internally until the tube wall ruptured. Leak rate, burst pressure, and eddy-current information were then correlated with the through-wall crack lengths as determined by metallographic examination. Results confirm the ability to measure the crack length with eddy-current techniques. Results also support analytical and empirical models developed by the nuclear industry in calculating critical crack lengths in roll transitions.

  20. Using an ultra-high speed camera to capture a tube expansion test

    CSIR Research Space (South Africa)

    Snyman, Izak M

    2016-09-01

    Full Text Available of such parameters is for the JWL equation of state that models the detonation of an explosive. Tube or cylinder expansion tests are a standard way to determine the JWL parameters of such an explosive. A streak camera normally captures the copper tube expansion...

  1. The fractional post-coital test performed in a square capillary tube.

    Science.gov (United States)

    Kroeks, M V; Kremer, J

    1975-12-01

    A new method of examination of post-coital cervical mucus was developed, with special attention to the moving spermatozoa. The test is performed in a square capillary tube (edge 0,8 mm). The migration rate, -- velocity and -- direction are measured by means of an ocular micrometer, which is seen projected over the capillary tube.

  2. Modeling and testing of a tube-in-tube separation mechanism of bodies in space

    Science.gov (United States)

    Michaels, Dan; Gany, Alon

    2016-12-01

    A tube-in-tube concept for separation of bodies in space was investigated theoretically and experimentally. The separation system is based on generation of high pressure gas by combustion of solid propellant and restricting the expansion of the gas only by ejecting the two bodies in opposite directions, in such a fashion that maximizes generated impulse. An interior ballistics model was developed in order to investigate the potential benefits of the separation system for a large range of space body masses and for different design parameters such as geometry and propellant. The model takes into account solid propellant combustion, heat losses, and gas phase chemical reactions. The model shows that for large bodies (above 100 kg) and typical separation velocities of 5 m/s, the proposed separation mechanism may be characterized by a specific impulse of 25,000 s, two order of magnitude larger than that of conventional solid rockets. It means that the proposed separation system requires only 1% of the propellant mass that would be needed for a conventional rocket for the same mission. Since many existing launch vehicles obtain such separation velocities by using conventional solid rocket motors (retro-rockets), the implementation of the new separation system design can reduce dramatically the mass of the separation system and increase safety. A dedicated experimental setup was built in order to demonstrate the concept and validate the model. The experimental results revealed specific impulse values of up to 27,000 s and showed good correspondence with the model.

  3. Characterization and single cell testing of Pt/C electrodes prepared by electrodeposition

    Energy Technology Data Exchange (ETDEWEB)

    Martin, A.J.; Chaparro, A.M.; Gallardo, B.; Folgado, M.A. [CIEMAT, Department of Energy, Avda. Complutense 22, 28040 Madrid (Spain); Daza, L. [CIEMAT, Department of Energy, Avda. Complutense 22, 28040 Madrid (Spain); Instituto de Catalisis y Petroleoquimica (CSIC), C/. Marie Curie 2, Campus Cantoblanco, 28049 Madrid (Spain)

    2009-07-01

    Electrodes for proton exchange membrane fuel cells (PEMFC) have been prepared by the electrodeposition method. For this task, the electrodeposition of platinum is carried out on a carbon black substrate impregnated with an ionomer, proton conducting, medium. Before electrodeposition, the substrate is submitted to an activation process to increase the hydrophilic character of the surface to a few microns depth. Electrodeposition of platinum takes place inside the generated surface hydrophilic layer, resulting in a continuous phase covering totally or partially carbon substrate grains. Cross sectional images show a decay profile of platinum towards the interior of the substrate, reflecting a deposition process limited by diffusion of PtCl{sub 6}{sup 2-} through the porous substrate. Electrodes with different platinum loads have been prepared, and membrane electrode assemblies (MEA) have been mounted with the electrodeposited electrodes as cathode and other standard components (commercial anode and Nafion{sup R} 117 membrane). The electrochemically active surface area determined from hydrogen underpotential deposition charge, is lower on the electrodeposited electrodes than on standard electrodes. However, single cell testing shows higher mass specific activity on electrodeposited cathodes with low and intermediate Pt load (below 0.05 mg Pt cm{sup -2}). (author)

  4. Characterization and single cell testing of Pt/C electrodes prepared by electrodeposition

    Science.gov (United States)

    Martín, A. J.; Chaparro, A. M.; Gallardo, B.; Folgado, M. A.; Daza, L.

    Electrodes for proton exchange membrane fuel cells (PEMFC) have been prepared by the electrodeposition method. For this task, the electrodeposition of platinum is carried out on a carbon black substrate impregnated with an ionomer, proton conducting, medium. Before electrodeposition, the substrate is submitted to an activation process to increase the hydrophilic character of the surface to a few microns depth. Electrodeposition of platinum takes place inside the generated surface hydrophilic layer, resulting in a continuous phase covering totally or partially carbon substrate grains. Cross sectional images show a decay profile of platinum towards the interior of the substrate, reflecting a deposition process limited by diffusion of PtCl 6 2- through the porous substrate. Electrodes with different platinum loads have been prepared, and membrane electrode assemblies (MEA) have been mounted with the electrodeposited electrodes as cathode and other standard components (commercial anode and Nafion R 117 membrane). The electrochemically active surface area determined from hydrogen underpotential deposition charge, is lower on the electrodeposited electrodes than on standard electrodes. However, single cell testing shows higher mass specific activity on electrodeposited cathodes with low and intermediate Pt load (below 0.05 mg Pt cm -2).

  5. The shock tube as a device for testing transonic airfoils at high Reynolds numbers

    Science.gov (United States)

    Cook, W. J.; Presley, L. L.; Chapman, G. T.

    1978-01-01

    A performance analysis of gas-driven shock tubes shows that transonic airfoil flows with chord Reynolds numbers in the range of 100 million can be generated behind the primary shock in a large shock tube. A study of flow over simple airfoils has been carried out at low and intermediate Reynolds numbers to assess the testing technique. Results obtained from schlieren photos and airfoil pressure measurements show that steady transonic flows similar to those observed for the airfoils in wind tunnels can be generated within the available testing time in a shock tube with either properly-contoured test section walls or a properly-designed slotted-wall test section. The study indicates that the shock tube is a useful facility for studying two-dimensional high Reynolds number transonic airfoil flows.

  6. Production and test of monitored drift tubes for the muon spectrometer of the ATLAS experiment

    CERN Document Server

    Aprile, A; Campagna, A; Capua, M; Cuce, D; Ferraro, E; Lamanna, E; La Rotonda, L; Meoni, E; Pellegrino, F; Romano, V; Schioppa, M; Susinno, G; Turco, R P; Vena, R

    2002-01-01

    ATLAS is one of the two general-purpose experiments being built for the Large Hadron Collider at CERN. Its muon spectrometer consists of very high-precision chambers made of drift tubes. Up to now, more than 5000 monitored drift tubes (MDTs) have been constructed and tested at the University of Calabria, Italy, for ATLAS barrel system chambers of the muon detector. This paper reports the critical MDT assembly techniques in detail, including the automatic electronics system and data acquisition system. The extensive tests performed on individual drift tubes and the first results and experience are also reported. (5 refs).

  7. Traveling-wave tube reliability estimates, life tests, and space flight experience

    Science.gov (United States)

    Lalli, V. R.; Speck, C. E.

    1977-01-01

    Infant mortality, useful life, and wearout phase of twt life are considered. The performance of existing developmental tubes, flight experience, and sequential hardware testing are evaluated. The reliability history of twt's in space applications is documented by considering: (1) the generic parts of the tube in light of the manner in which their design and operation affect the ultimate reliability of the device, (2) the flight experience of medium power tubes, and (3) the available life test data for existing space-qualified twt's in addition to those of high power devices.

  8. Qualification Tests of the R11410-21 Photomultiplier Tubes for the XENON1T Detector

    CERN Document Server

    Barrow, P; Cichon, D; Danisch, M; Franco, D; Kaether, F; Kish, A; Lindner, M; Undagoitia, T Marrodan; Mayani, D; Rauch, L; Wei, Y; Wulf, J

    2016-01-01

    The Hamamatsu R11410-21 photomultiplier tube is the photodetector of choice for the XENON1T dual-phase time projection chamber. The device has been optimized for a very low intrinsic radioactivity, a high quantum efficiency and a high sensitivity to single photon detection. A total of 248 tubes are currently operated in XENON1T, selected out of 321 tested units. In this article the procedures implemented to evaluate the large number of tubes prior to their installation in XENON1T are described. The parameter distributions for all tested tubes are shown, with an emphasis on those selected for XENON1T, of which the impact on the detector performance is discussed. All photomultipliers have been tested in a nitrogen atmosphere at cryogenic temperatures, with a subset of the tubes being tested in gaseous and liquid xenon, simulating their operating conditions in the dark matter detector. The performance and evaluation of the tubes in the different environments is reported and the criteria for rejection of PMTs are...

  9. Performance tests of the 1MWt shell-and-tube heat exchangers for OTEC

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, A.; Lorenz, J. J.; Hillis, D. L.; Yung, D. T.; Sather, N. P.

    1979-01-01

    Final test results are reported for the five 1 MWt shell-and-tube heat exchangers tested at Argonne National Laboratory. These five heat exchangers are the Union Carbide flooded-bundle evaporator, the Union Carbide sprayed-bundle evaporator, the Union Carbide enhanced-tube condenser, the Carnegie-Mellon vertical fluted-tube evaporator, and the Carnegie-Mellon vertical fluted-tube condenser. Performance parameters measured include the overall heat transfer coefficient (U/sub 0/), the water-side pressure drop, and the vapor quality. Also measured were operational characteristics of the heat exchangers such as repeatability of results and the dependence of U/sub 0/ on heat duty, ammonia flow rate, and subcooling. Individual water-side and ammonia-side coefficients were deduced using the Wilson Plot method.

  10. Controlatron Neutron Tube Test Suite Software Manual - Operation Manual (V2.2)

    CERN Document Server

    Noel, W P; Hertrich, R J; Martinez, M L; Wallace, D L

    2002-01-01

    The Controlatron Software Suite is a custom built application to perform automated testing of Controlatron neutron tubes. The software package was designed to allowing users to design tests and to run a series of test suites on a tube. The data is output to ASCII files of a pre-defined format for data analysis and viewing with the Controlatron Data Viewer Application. This manual discusses the operation of the Controlatron Test Suite Software and a brief discussion of state machine theory, as state machine is the functional basis of the software.

  11. Studies of the steam generator degraded tubes behavior on BRUTUS test loop

    Energy Technology Data Exchange (ETDEWEB)

    Chedeau, C.; Rassineux, B. [EDF/DER/MTC, Moret Sur Loing (France); Flesch, B. [EDF/EPN/DMAINT, Paris (France)] [and others

    1997-04-01

    Studies for the evaluation of steam generator tube bundle cracks in PWR power plants are described. Global tests of crack leak rates and numerical calculations of crack opening area are discussed in some detail. A brief overview of thermohydraulic studies and the development of a mechanical probabilistic design code is also given. The COMPROMIS computer code was used in the studies to quantify the influence of in-service inspections and maintenance work on the risk of a steam generator tube rupture.

  12. NASA Lewis Stirling SPRE testing and analysis with reduced number of cooler tubes

    Energy Technology Data Exchange (ETDEWEB)

    Wong, W.A.; Cairelli, J.E.; Swec, D.M.; Doeberling, T.J.; Lakatos, T.F. [National Aeronautics and Space Administration, Cleveland, OH (United States). Lewis Research Center; Madi, F.J. [Sverdrup Technology, Inc., Cleveland, OH (United States). Lewis Research Center Group

    1994-09-01

    Free-piston Stirling power converters are a candidate for high capacity space power applications. The Space Power Research Engine (SPRE), a free-piston Stirling engine coupled with a linear alternator, is being tested at the NASA Lewis Research Center in support of the Civil Space Technology Initiative. The SPRE is used as a test bed for evaluating converter modifications which have the potential to improve converter performance and for validating computer code predictions. Reducing the number of cooler tubes on the SPRE has been identified as a modification with the potential to significantly improve power and efficiency. This paper describes experimental tests designed to investigate the effects of reducing the number of cooler tubes on converter power, efficiency and dynamics. Presented are test results from the converter operating with a reduced number of cooler tubes and comparisons between this data and both baseline test data and computer code predictions.

  13. NASA Lewis Stirling SPRE testing and analysis with reduced number of cooler tubes

    Science.gov (United States)

    Wong, Wayne A.; Cairelli, James E.; Swec, Diane M.; Doeberling, Thomas J.; Lakatos, Thomas F.; Madi, Frank J.

    1992-08-01

    Free-piston Stirling power converters are candidates for high capacity space power applications. The Space Power Research Engine (SPRE), a free-piston Stirling engine coupled with a linear alternator, is being tested at the NASA Lewis Research Center in support of the Civil Space Technology Initiative. The SPRE is used as a test bed for evaluating converter modifications which have the potential to improve the converter performance and for validating computer code predictions. Reducing the number of cooler tubes on the SPRE has been identified as a modification with the potential to significantly improve power and efficiency. Experimental tests designed to investigate the effects of reducing the number of cooler tubes on converter power, efficiency and dynamics are described. Presented are test results from the converter operating with a reduced number of cooler tubes and comparisons between this data and both baseline test data and computer code predictions.

  14. Risks of Using Bedside Tests to Verify Nasogastric Tube Position in Adult Patients

    Directory of Open Access Journals (Sweden)

    Melody Ni

    2014-12-01

    Full Text Available Nasogastric (NG tubes are commonly used for enteral feeding. Complications of feeding tube misplacement include malnutrition, pulmonary aspiration, and even death. We built a Bayesian network (BN to analyse the risks associated with available bedside tests to verify tube position. Evidence on test validity (sensitivity and specificity was retrieved from a systematic review. Likelihood ratios were used to select the best tests for detecting tubes misplaced in the lung or oesophagus. Five bedside tests were analysed including magnetic guidance, aspirate pH, auscultation, aspirate appearance, and capnography/colourimetry. Among these, auscultation and appearance are non-diagnostic towards lung or oesophagus placements. Capnography/ colourimetry can confirm but cannot rule out lung placement. Magnetic guidance can rule out both lung and oesophageal placement. However, as a relatively new technology, further validation studies are needed. The pH test with a cut-off at 5.5 or lower can rule out lung intubation. Lowering the cut-off to 4 not only minimises oesophageal intubation but also provides extra safety as the sensitivity of pH measurement is reduced by feeding, antacid medication, or the use of less accurate pH paper. BN is an effective tool for representing and analysing multi-layered uncertainties in test validity and reliability for the verification of NG tube position. Aspirate pH with a cut-off of 4 is the safest bedside method to minimise lung and oesophageal misplacement.

  15. Testing of a Complete Training Model for Chest Tube Insertion in Traumatic Pneumothorax.

    Science.gov (United States)

    Ghazali, Aiham; Breque, Cyril; Léger, Alexandre; Scépi, Michel; Oriot, Denis

    2015-08-01

    Chest tube insertion is a frequent procedure in cases of traumatic pneumothorax, but severe complications can occur if not well performed. Although simulation-based training in chest tube insertion has improved performance, an affordable and realistic model for surgical insertion of a chest tube is lacking. The objective was to design a model for surgical chest tube insertion that would be realistic, affordable, and transportable and that would reflect all extrathoracic and intrathoracic steps of the procedure. The model was a task trainer designed by 4 experts in our simulation laboratory combining plastic, electronic, and biologic material. The cost of supplies needed for construction was evaluated. The model was used and tested over 30 months on 56 participants, of whom 44 were surveyed regarding the realism of the model. The model involved a half chest wall (lamb) on a plastic box, connected to a webcam facilitating assessment of the extrathoracic and intrathoracic steps of the procedure, for a cost of €60. Chest tubes, water seal package, and sterile instruments costed €200. All anatomic structures were represented during surgical insertion of chest tube. The demonstration contributed to teaching small groups of up to 8 participants and was reproducible over 30 months of diversely located courses. Anatomic correlation, realism, and learning experience were highly rated by users. This model for surgical chest tube insertion in traumatic pneumothorax was found to be realistic, affordable, and transportable. Furthermore, it allowed comprehensive assessment of the extrathoracic and intrathoracic procedural steps.

  16. Fracture Testing at Small-Length Scales: From Plasticity in Si to Brittleness in Pt

    Science.gov (United States)

    Jaya, B. Nagamani; Jayaram, Vikram

    2016-01-01

    The field of micro-/nano-mechanics of materials has been driven, on the one hand by the development of ever smaller structures in devices, and, on the other, by the need to map property variations in large systems that are microstructurally graded. Observations of `smaller is stronger' have also brought in questions of accompanying fracture property changes in the materials. In the wake of scattered articles on micro-scale fracture testing of various material classes, this review attempts to provide a holistic picture of the current state of the art. In the process, various reliable micro-scale geometries are shown, challenges with respect to instrumentation to probe ever smaller length scales are discussed and examples from recent literature are put together to exhibit the expanse of unusual fracture response of materials, from ductility in Si to brittleness in Pt. Outstanding issues related to fracture mechanics of small structures are critically examined for plausible solutions.

  17. Comparative testing for weak expression of D antigen: manual tube testing vs. a semiautomated IgG gel system.

    Science.gov (United States)

    Martinez, B; Crews, E; Dowd, A; M McMahan, M

    2003-01-01

    Donor RBCs nonreactive in initial tests for D must be tested further for evidence of weak expression of D antigen. Performing this test in test tubes is labor intensive and prone to inconsistencies in readings (relative strength of agglutination) and interpretation (positive versus negative). These inconsistencies can lead to repeat testing, additional documentation, and delay in releasing units. We evaluated use of the Tecan MEGAFlex-ID pipettor to perform this test in anti-IgG gel cards. Results with this semi-automated gel test were compared with results obtained with 37 D- and 99 weak D samples, as determined by previous testing with a manual IAT tube test. Hands-on time was determined for both methods and both methods were evaluated for inconsistency, or nonagreement, between the interpretation of the current weak D test and the results on record for any prior donations. There were no discordant results obtained, with the majority of weak D samples giving stronger reactions with the gel test. The semiautomated gel test required less hands-on time, with an average savings of more than 70 seconds per test. There were no inconsistencies with the gel method, whereas manual tube testing was found to have an inconsistency rate of 0.035 percent of total samples tested. Semiautomated IgG gel is now used for all weak D testing, with a labor savings of more than 10 hours per week. Thus far, more than 70,000 donors have been tested, with no inconsistencies reported.

  18. Film Platinum Thermal Resistance PT1000 Application in Thermal Test%薄膜铂热电阻PT1000在热测试中的应用

    Institute of Scientific and Technical Information of China (English)

    陆心宇; 郭庆

    2016-01-01

    The thermal test of electronic equipment is complete thermal analysis and thermal design in electronic equipment and complete the prototype, the prototype of electronic equipment in the actual test, to verify the effect of the thermal design and thermal analysis. Eight-way real-time temperature measuring device PT1000 is adopted as a temperature sensor. To meet the needs of the hot test, the article gives the eight-way temperature measuring device design process.%电子设备的热测试是在电子设备完成热分析、热设计和完成样机之后,对电子设备样机的实际测试,以检测验证热设计与热分析的正确性。八路温度实时测量装置采用了薄膜铂热电阻PT1000作为温度传感器,以满足热测试的需求,文章给出了八路实时温度测量装置设计和工作原理。

  19. Analysis and testing of high entrainment single nozzle jet pumps with variable mixing tubes

    Science.gov (United States)

    Hickman, K. E.; Hill, P. G.; Gilbert, G. B.

    1972-01-01

    An analytical model was developed to predict the performance characteristics of axisymmetric single-nozzle jet pumps with variable area mixing tubes. The primary flow may be subsonic or supersonic. The computer program uses integral techniques to calculate the velocity profiles and the wall static pressures that result from the mixing of the supersonic primary jet and the subsonic secondary flow. An experimental program was conducted to measure mixing tube wall static pressure variations, velocity profiles, and temperature profiles in a variable area mixing tube with a supersonic primary jet. Static pressure variations were measured at four different secondary flow rates. These test results were used to evaluate the analytical model. The analytical results compared well to the experimental data. Therefore, the analysis is believed to be ready for use to relate jet pump performance characteristics to mixing tube design.

  20. Studies on an improved indigenous pressure wave generator and its testing with a pulse tube cooler

    Science.gov (United States)

    Jacob, S.; Karunanithi, R.; Narsimham, G. S. V. L.; Kranthi, J. Kumar; Damu, C.; Praveen, T.; Samir, M.; Mallappa, A.

    2014-01-01

    Earlier version of an indigenously developed Pressure Wave Generator (PWG) could not develop the necessary pressure ratio to satisfactorily operate a pulse tube cooler, largely due to high blow by losses in the piston cylinder seal gap and due to a few design deficiencies. Effect of different parameters like seal gap, piston diameter, piston stroke, moving mass and the piston back volume on the performance is studied analytically. Modifications were done to the PWG based on analysis and the performance is experimentally measured. A significant improvement in PWG performance is seen as a result of the modifications. The improved PWG is tested with the same pulse tube cooler but with different inertance tube configurations. A no load temperature of 130 K is achieved with an inertance tube configuration designed using Sage software. The delivered PV power is estimated to be 28.4 W which can produce a refrigeration of about 1 W at 80 K.

  1. Results of experimental tests simulating supply pressure decrease in a K process tube

    Energy Technology Data Exchange (ETDEWEB)

    Toyoda, K.G.; Calkin, J.F.

    1957-11-13

    Simultaneous reduction of coolant to several or all reactor tubes raises concern not only for the adequacy of protection in the individual process tube but also the reactor as a whole. In event of such flow reduction, the heat generation does not decrease until at least 1.4 seconds have elapsed following the accident. Thus, the water temperature from each tube will rise, and result in an increase in the bulk water temperature. If the increase in bulk water temperature is such that saturation temperature at the top of downcomer is reached, pressurization may occur at that point and exceed the maximum recommended working pressure limit (approximately 1 to 2 psig). The purpose of this report is to present experimental data on a series of tests which were made to simulate flow reductions to a K type process tube by simulated front header pressure decreases.

  2. Application of shock tubes to transonic airfoil testing at high Reynolds numbers

    Science.gov (United States)

    Cook, W. J.; Chaney, M. J.; Presley, L. L.; Chapman, G. T.

    1978-01-01

    Performance analysis of a gas-driven shock tube shows that transonic airfoil flows with chord Reynolds numbers of the order of 100 million can be produced, with limitations being imposed by the structural integrity of the facility or the model. A study of flow development over a simple circular arc airfoil at zero angle of attack was carried out in a shock tube at low and intermediate Reynolds numbers to assess the testing technique. Results obtained from schlieren photography and airfoil pressure measurements show that steady transonic flows similar to those produced for the same airfoil in a wind tunnel can be generated within the available testing time in a shock tube with properly contoured test section walls.

  3. Forming limit diagram of aluminum AA6063 tubes at high temperatures by bulge tests

    Energy Technology Data Exchange (ETDEWEB)

    Hashemi, Seyed Jalal; Naeini, Hassan Moslemi; Liaghat, Gholamhossein [Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Tafti, Rooholla Azizi [Yazd University, Yazd (Iran, Islamic Republic of); Rahmani, Farzad [Kar Higher Education Institute, Qazvin (Iran, Islamic Republic of)

    2014-11-15

    A free bulge test and ductile fracture criteria were used to obtain the forming limit diagrams (FLD) of aluminum alloy AA6063 tubes at high temperatures. Ductile fracture criteria were calibrated using the results of uniaxial tension tests at various elevated temperatures and different strain rates through adjusting the Zener-Holloman parameter. High temperature free bulge test of tubes was simulated in finite element software Abaqus, and tube bursting was predicted using ductile fracture criteria under different loading paths. FLDs which were obtained from finite element simulation were compared to experimental results to select the most accurate criterion for prediction of forming limit diagram. According to the results, all studied ductile fracture criteria predict similarly when forming condition is close to the uniaxial tension, while Ayada criterion predicts the FLD at 473 K and 573 K very well.

  4. A versatile test bench for photomultiplier tube characterization and its application in the DAMPE-PSD

    CERN Document Server

    Zhou, Yong; Yu, Yuhong; Zhang, Yongjie; Fang, Fang; Chen, Junling; Hu, Bitao

    2016-01-01

    A versatile test bench system, dedicated for massive PMT characterization, is developed at the Institute of Modern Physics, Chinese Academy of Sciences. It can perform many test contents with large capacity and high level of automation, and the migration from one testing configuration to another is lightweight and time-saving. This system has been used in the construction of the Plastic Scintillator Detector of DArk Matter Particle Explorer already, and a total of 570 Hamamatsu R4443 tubes have been tested successfully.

  5. Testing of photomultiplier tubes for use in the surface detector of the Pierre Auger observatory

    Energy Technology Data Exchange (ETDEWEB)

    Barnhill, D. [Department of Physics and Astronomy, UCLA, Los Angeles, CA 90095-1547 (United States)], E-mail: david.scott.barnhill@gmail.com; Suarez, F. [INFN, Universita degli Studi di Torino (Italy)], E-mail: fedesuarez@auger.org.ar; Arisaka, K. [Department of Physics and Astronomy, UCLA, Los Angeles, CA 90095-1547 (United States); Garcia, B. [UTN-FRM Mendoza (Argentina); Gongora, J.P. [UTN-FRSR San Rafael (Argentina); Lucero, A.; Navarro, I. [UTN-FRM Mendoza (Argentina); Ohnuki, T. [Department of Physics and Astronomy, UCLA, Los Angeles, CA 90095-1547 (United States); Risi, A. [UTN-FRSR San Rafael (Argentina); Tripathi, A. [Department of Physics and Astronomy, UCLA, Los Angeles, CA 90095-1547 (United States)

    2008-07-01

    In the array of water Cherenkov detectors of the Pierre Auger Observatory, 4800 large photomultiplier tubes (PMTs) will be used. Before being deployed, each PMT is evaluated to check that various parameters, such as the linearity, dark noise, and gain, fall within a specified range. The large scale test system, designed and constructed for this purpose, is capable of testing multiple large PMTs simultaneously. The test system and the results of the tests for the first 3964 PMTs are presented in this paper.

  6. Fireside corrosion testing of candidate superheater tube alloys, coatings, and claddings -- Phase 2 field testing

    Energy Technology Data Exchange (ETDEWEB)

    Blough, J.L.; Seitz, W.W.; Girshik, A. [Foster Wheeler Development Corp., Livingston, NJ (United States)

    1998-06-01

    In Phase 1 of this project, laboratory experiments were performed on a variety of developmental and commercial tubing alloys and claddings by exposing them to fireside corrosion tests which simulated a superheater or reheater in a coal-fired boiler. Phase 2 (in situ testing) has exposed samples of 347, RA85H, HR3C, RA253MA, Fe{sub 3}Al + 5Cr, Ta-modified 310, NF 709, 690 clad, 671 clad, and 800HT for up to approximately 16,000 hours to the actual operating conditions of a 250-MW, coal-fired boiler. The samples were installed on air-cooled, retractable corrosion probes, installed in the reheater cavity, and controlled to the operating metal temperatures of an existing and advanced-cycle, coal-fired boiler. Samples of each alloy were exposed for 4,483, 11,348, and 15,883 hours of operation. The present results are for the metallurgical examination of the corrosion probe samples after the full 15,883 hours of exposure. A previous topical report has been issued for the 4,483 hours of exposure.

  7. Concept of a Pitot tube able to detect blockage by ice, volcanic ash, sand and insects, and to clear the tube

    Science.gov (United States)

    Jackson, David A.

    2015-12-01

    A conceptual coaxial Pitot tube (PT) has been developed using fiber optic sensors combined with actuators to monitor and maintain its correct operation under different environmental conditions. Experiments were performed showing that the dynamic and static tubes can be cleared of ice. It was also demonstrated that the dynamic tube could be cleared of dust and sand which was not the case for the static tube in the coaxial configuration. An approach was proposed to overcome this problem involving a conventional configuration where the static tube was operated independently orthogonal to the dynamic tube, and a second set of sensors and actuators was used. Sensors and associated actuators were developed for temperature and intensity for a linear PT. The aim of this work is to propose a solution for a problem that has caused the loss of the lives of many passengers and crew of aircraft. Resources were not available to test a full implementation of a PT incorporating the proposed modifications.

  8. Circumferential tensile test method for mechanical property evaluation of SiC/SiC tube

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Ju-Hyeon, E-mail: 15096018@mmm.muroran-it.ac.jp [Graduate School, Muroran Institute of Technology, 27-1, Muroran, Hokkaido (Japan); Kishimoto, Hirotatsu [Graduate School, Muroran Institute of Technology, 27-1, Muroran, Hokkaido (Japan); OASIS, Muroran Institute of Technology, 27-1, Muroran, Hokkaido (Japan); Park, Joon-soo [OASIS, Muroran Institute of Technology, 27-1, Muroran, Hokkaido (Japan); Nakazato, Naofumi [Graduate School, Muroran Institute of Technology, 27-1, Muroran, Hokkaido (Japan); Kohyama, Akira [OASIS, Muroran Institute of Technology, 27-1, Muroran, Hokkaido (Japan)

    2016-11-01

    Highlights: • NITE SiC/SiC cooling channel system to be a candidate of divertor system in future. • Hoop strength is one of the important factors for a tube. • This research studies the relationship between deformation and strain of SiC/SiC tube. - Abstract: SiC fiber reinforced/SiC matrix (SiC/SiC) composite is expected to be a candidate material for the first-wall, components in the blanket and divertor of fusion reactors in future. In such components, SiC/SiC composites need to be formed to be various shapes. SiC/SiC tubes has been expected to be employed for blanket and divertor after DEMO reactor, but there is not established mechanical investigation technique. Recent progress of SiC/SiC processing techniques is likely to realize strong, having gas tightness SiC/SiC tubes which will contribute for the development of fusion reactors. This research studies the relationship between deformation and strain of SiC/SiC tube using a circumferential tensile test method to establish a mechanical property investigation method of SiC/SiC tubes.

  9. Research on automatic non-destructive testing system of oil coiled tubing

    Science.gov (United States)

    Guo, Rong; Qiu, Wenbin; Wang, Yuhui; Ren, Jianguang

    2010-10-01

    A method using ultrasonic devices for on-line measurement of oil coiled tubing was proposed. The principle of ultrasonic testing was analyzed. Then, the structure of the system consisting of mechanical system, coupling system, measuring system, control system and system software was determinated. Based on the analysis of technology requirement, measuring technique in which the coiled tubing did not rotate and the probe was static was chosen. The ultrasonic testing probes were triggered in turn. After signal sampling, digital filtering and A / D conversion signal processing, the received echo signals were sent to computer. Through analyzing and accounting, the test results were obtained. Based on VC++.net, A-type ultrasonic and C-type ultrasonic display software and the inspection data processing software were developed. Using Windows programming technology, the software structure and function library were totally open. Therefore, secondary development can be carried out conveniently. Based on the experimental studies, coiled tubing's ultrasonic testing system is developed. The testing results show that the system has specific advantages such as high-adaptation, highefficiency, high- stability, high reliability and can meet the need of the users. The ultrasonic testing technologies proposed in this paper can be applied extensively to other tubes.

  10. A prediction method for the general corrosion behavior of Alloy 690 steam generator tube using eddy current testing

    Energy Technology Data Exchange (ETDEWEB)

    Shim, Hee-Sang; Choi, Myung Sik; Lee, Deok Hyun; Hur, Do Haeng, E-mail: dhhur@kaeri.re.kr

    2016-02-15

    Highlights: • A corrosion test for the tubes with different levels of eddy current noise was conducted. • A relationship between the corrosion rate and the eddy current noise of tubes was explored. • Corrosion rate was closely correlated to the tube noise of a rotating pancake probe. • Corrosion rate was not related to the tube noise measured using a bobbin probe. - Abstract: The purpose of this work is to develop an eddy current testing method to predict the general corrosion behavior of Alloy 690 steam generator tubes. A corrosion test was conducted for tubes with different levels of eddy current noise in simulated primary water at 330 °C, and their corrosion behavior was correlated with the tube noise measured using bobbin and rotating probes. The corrosion behavior was closely correlated with the tube noise measured using a rotating probe. However, there was no correlation between the corrosion behavior and the tube noise measured using a bobbin probe. The tube noise value measured using a rotating pancake coil probe is suggested to be a significant parameter in estimating the general corrosion behavior of tubes.

  11. Laboratory evaluation of the improved tube test detection limits for β ...

    African Journals Online (AJOL)

    Administrator

    Laboratory evaluation of the improved tube test ... method, which could be used for qualitative identification of residues in ... particular commonly utilised in lactating animals (Mandell ... boiled in a waterbath for 10 min before being used in Nutrient agar ... Adulterated samples as well as normal control samples were.

  12. Dr. Chang Min Chueh——Father of Test Tube Babies

    Institute of Scientific and Technical Information of China (English)

    1994-01-01

    CHANG Min Chueh (1908-1991)—the father of test tube babies, was a Chinese-born American scientist and inventor who developed the first oral contraceptives. Dr. Chang was from Dunhou Township, Lanxian County, Shanxi Province. In middle school, he was fascinated with biology. Later he was accepted to the Animal Psychology Department at Qinghua University.

  13. Use of Mueller-Hinton broth and agar in the germ tube test.

    Science.gov (United States)

    Mattei, Antonella Souza; Alves, Sydney Hartz; Severo, Cecília Bittencourt; Guazzelli, Luciana da Silva; Oliveira, Flávio de Mattos; Severo, Luiz Carlos

    2014-01-01

    Candida albicans is often isolated from clinical samples, thus its presumptive differentiation from other species of the same genus can be based on its ability to form the germ tube in human serum. Nevertheless, there are two other species that share this characteristic: C. dubliniensis and C. africana. The aim of this study was to compare four different substrates to perform the germ tube (GT) test. The Candida spp. isolates were identified using a manual system (135 C. albicans, 24 C. tropicalis and one C. dubliniensis). The germ tube test was performed with fresh, previously frozen serum and Mueller-Hinton (MH) broth and agar. GT was observed in 96% (130/136) of the isolates through the fresh serum technique, 94% (128/136) through previously frozen serum, 92% (125/136) in MH agar, and 90% (122/136) in MH broth. The sensitivity of each test was higher than 90%, with 100% specificity. Both the MH agar and broth were able to identify the true positives, and false positives were not found. However, some C. albicans isolates were not identified. MH agar and broth may be used in laboratory for the rapid presumptive identification of C. albicans, as an alternative method for germ tube test.

  14. QuantiFERON–TB Gold In-Tube test performance in Denmark

    DEFF Research Database (Denmark)

    Hermansen, Thomas; Lillebaek, Troels; Hansen, Ann-Brit E;

    2014-01-01

    BACKGROUND: Little is known about the QuantiFERON-TB Gold In-Tube Test (QFT) in extreme age groups. The test performance has been reported to be impaired in children and elderly, but reports are diverging. The aim of this study was to evaluate QFT performance in patients with and without Tubercul...... in children ≥ 1 years in low endemic regions but that the test should be used with care among the elderly.......BACKGROUND: Little is known about the QuantiFERON-TB Gold In-Tube Test (QFT) in extreme age groups. The test performance has been reported to be impaired in children and elderly, but reports are diverging. The aim of this study was to evaluate QFT performance in patients with and without...

  15. Setup a photomultiplier tube test bench for use at LHAASO-KM2A

    CERN Document Server

    Wang, Xu; Tian, Ye; Li, Changyu; Sun, Yansheng; Feng, Cunfeng

    2015-01-01

    To fulfill the requirements of testing the photomultiplier tubes of the electromagnetic detector at the Large High Altitude Air Shower Observatory (LHAASO), a multi-functional PMT test bench with a two-dimensional scanning system is developed. With this 2D scanning system, 16 PMTs are scanned simultaneously to test their uniformity and cathode transit time difference, and we can also perform PMT tests of SPE spectrum, gain vs. high voltage, linear behavior and dark noise. The programmable hardware and intelligent software of the test bench make it convenient to use and provide reliable results. The test methods are described in detail and primary results are presented.

  16. Drip and Mate Operations Acting in Test Tube Systems and Tissue-like P systems

    CERN Document Server

    Freund, Rudolf; 10.4204/EPTCS.11.8

    2009-01-01

    The operations drip and mate considered in (mem)brane computing resemble the operations cut and recombination well known from DNA computing. We here consider sets of vesicles with multisets of objects on their outside membrane interacting by drip and mate in two different setups: in test tube systems, the vesicles may pass from one tube to another one provided they fulfill specific constraints; in tissue-like P systems, the vesicles are immediately passed to specified cells after having undergone a drip or mate operation. In both variants, computational completeness can be obtained, yet with different constraints for the drip and mate operations.

  17. Elastic Stability of Concentric Tube Robots: A Stability Measure and Design Test

    Science.gov (United States)

    Gilbert, Hunter B.; Hendrick, Richard J.; Webster, Robert J.

    2016-01-01

    Concentric tube robots are needle-sized manipulators which have been investigated for use in minimally invasive surgeries. It was noted early in the development of these devices that elastic energy storage can lead to rapid snapping motion for designs with moderate to high tube curvatures. Substantial progress has recently been made in the concentric tube robot community in designing snap-free robots, planning stable paths, and characterizing conditions that result in snapping for specific classes of concentric tube robots. However, a general measure for how stable a given robot configuration is has yet to be proposed. In this paper, we use bifurcation and elastic stability theory to provide such a measure, as well as to produce a test for determining whether a given design is snap-free (i.e. whether snapping can occur anywhere in the unloaded robot’s workspace). These results are useful in designing, planning motions for, and controlling concentric tube robots with high curvatures. PMID:27042170

  18. Traveling-Wave Tube Cold-Test Circuit Optimization Using CST MICROWAVE STUDIO

    Science.gov (United States)

    Chevalier, Christine T.; Kory, Carol L.; Wilson, Jeffrey D.; Wintucky, Edwin G.; Dayton, James A., Jr.

    2003-01-01

    The internal optimizer of CST MICROWAVE STUDIO (MWS) was used along with an application-specific Visual Basic for Applications (VBA) script to develop a method to optimize traveling-wave tube (TWT) cold-test circuit performance. The optimization procedure allows simultaneous optimization of circuit specifications including on-axis interaction impedance, bandwidth or geometric limitations. The application of Microwave Studio to TWT cold-test circuit optimization is described.

  19. First joint test beam of CMS Drift Tubes (DT) and Resistive Plate Chambers (RPC)

    CERN Multimedia

    Paolo Giacomelli

    2001-01-01

    The first full size muon drift tube chamber ever built for the CMS barrel with the final cell design (constructed at CIEMAT, Madrid) was succesfully tested with a muon beam in September 2001 at the Gamma Irradiation Facility (GIF) at CERN. For the first time also both muon detectors for the CMS barrel (DT + RPC) were coupled together. The results of this test were fully succesful and confirmed the excellent performance of both detectors together in a radiation environment.

  20. Within-Subject Interlaboratory Variability of QuantiFERON-TB Gold In-Tube Tests

    Science.gov (United States)

    2012-09-06

    Jaffar3,5¤c, Wanzer Drane7, David Maserang8¤d, Gerald H. Mazurek1 1 Division of Tuberculosis Elimination, Centers for Disease Control and Prevention, Atlanta...Georgia, United States of America, 2 Department of Medicine, Tripler Army Medical Center, Honolulu, Hawaii, United States of America, 3 Epidemiology ...QuantiFERONH-TB Gold In-Tube test (QFT-GIT) is a viable alternative to the tuberculin skin test (TST) for detecting Mycobacterium tuberculosis infection

  1. Physical design and cooling test of C-band standing wave accelerating tube

    Institute of Scientific and Technical Information of China (English)

    Bai Wei; Xu Zhou; Jin Xiao; Li Ming

    2006-01-01

    The physical design and cooling test of a C-band 2MeV standing wave (SW) accelerating tube are described in this paper. The designed accelerating structure consists of 3-cell buncher and 4-cell accelerating section with a total length of about 163mm , excited with 1MW magnetron. Dynamic simulation presents that about 150mA beam pulse current and 30% capture efficiency can be achieved. By means of nonlinear Gauss fit on electron transverse distribution, the diameter of beam spot FWHM (full width at half maximum of density distribution) is about 0.55mm. Cooling test results of the accelerating tube show that frequencies of cavities are tuned to 5527MHz and the field distribution of bunching section is about 3:9:10.

  2. Photocathode-Uniformity Tests of the Hamamatsu R5912 Photomultiplier Tubes Used in the Milagro Experiment

    CERN Document Server

    Vasileiou, V; Smith, A J

    2007-01-01

    The Milagro experiment observes the extensive air showers produced by very high energy gamma-rays impacting the Earth's atmosphere. Milagro uses 898 Hamamatsu R5912 Photomultiplier Tubes. To complete our Monte Carlo simulations, we tested the photocathode uniformity of our PMTs. The main finding was that the PMT gain and detection efficiency are a function of the distance from the center of the photocathode. Both quantities become considerably smaller as the illumination position nears the edge of the photocathode.

  3. NASTRAN Analysis Comparison to Shock Tube Tests Used to Simulate Nuclear Overpressures

    Science.gov (United States)

    Wheless, T. K.

    1985-01-01

    This report presents a study of the effectiveness of the NASTRAN computer code for predicting structural response to nuclear blast overpressures. NASTRAN's effectiveness is determined by comparing results against shock tube tests used to simulate nuclear overpressures. Seven panels of various configurations are compared in this study. Panel deflections are the criteria used to measure NASTRAN's effectiveness. This study is a result of needed improvements in the survivability/vulnerability analyses subjected to nuclear blast.

  4. A cryogenic tensile testing apparatus for micro-samples cooled by miniature pulse tube cryocooler

    Science.gov (United States)

    Chen, L. B.; Liu, S. X.; Gu, K. X.; Zhou, Y.; Wang, J. J.

    2015-12-01

    This paper introduces a cryogenic tensile testing apparatus for micro-samples cooled by a miniature pulse tube cryocooler. At present, tensile tests are widely applied to measure the mechanical properties of materials; most of the cryogenic tensile testing apparatus are designed for samples with standard sizes, while for non-standard size samples, especially for microsamples, the tensile testing cannot be conducted. The general approach to cool down the specimens for tensile testing is by using of liquid nitrogen or liquid helium, which is not convenient: it is difficult to keep the temperature of the specimens at an arbitrary set point precisely, besides, in some occasions, liquid nitrogen, especially liquid helium, is not easily available. To overcome these limitations, a cryogenic tensile testing apparatus cooled by a high frequency pulse tube cryocooler has been designed, built and tested. The operating temperatures of the developed tensile testing apparatus cover from 20 K to room temperature with a controlling precision of ±10 mK. The apparatus configurations, the methods of operation and some cooling performance will be described in this paper.

  5. Reflections on "YouTestTube.com": An Online Video-Sharing Platform to Engage Students with Chemistry Laboratory Classes

    Science.gov (United States)

    McClean, Stephen; McCartan, Kenneth G.; Meskin, Sheryl; Gorges, Beronia; Hagan, W. Paul

    2016-01-01

    This paper describes the construction and development of YouTestTube.com, a YouTube clone website to facilitate video-sharing, social networking, and reflections of chemistry laboratory classes for year one students within the School of Biomedical Sciences at Ulster University. The practice was first introduced in the 2008/09 academic year and has…

  6. Reflections on "YouTestTube.com": An Online Video-Sharing Platform to Engage Students with Chemistry Laboratory Classes

    Science.gov (United States)

    McClean, Stephen; McCartan, Kenneth G.; Meskin, Sheryl; Gorges, Beronia; Hagan, W. Paul

    2016-01-01

    This paper describes the construction and development of YouTestTube.com, a YouTube clone website to facilitate video-sharing, social networking, and reflections of chemistry laboratory classes for year one students within the School of Biomedical Sciences at Ulster University. The practice was first introduced in the 2008/09 academic year and has…

  7. Analysis and two years of testing of the vee-trough concentrator/evacuated tube solar collector

    Science.gov (United States)

    Selcuk, M. K.; Aghan, A.

    1979-01-01

    The paper summarizes the mathematical analysis and presents the experimental results for a vee-trough/evacuated tube collector (VTETC). Test results reported represent the performance of the VTETC based on an aperture area. The effectiveness of vee-trough reflectors is demonstrated by comparing the useful heat collected by a receiver tube with and without concentrators.

  8. Comparison of tuberculin skin test and quantiferon-TB gold in tube test for diagnosis of latent tuberculosis infection in health care workers: A cross sectional study.

    Science.gov (United States)

    Bozkanat, Erkan; Kaya, Hatice; Sezer, Ogun; Caliskan, Tayfun; Kilic, Erol; Ciftci, Faruk; Gumus, Seyfettin; Kartaloglu, Zafer

    2016-03-01

    To compare the diagnostic efficacy and agreement of the traditional tuberculin skin test with QuantiFERON-Tuberculosis Gold In-Tube test for latent tuberculosis infection in healthcare workers. The cross-sectional analytical study was conducted between March 1 and 31, 2008, at a specialist tuberculosis hospital in Istanbul, Turkey, and comprised healthcare workers who had been employed for at least one year at the hospital and volunteered to take part. Tuberculin skin test and QuantiFERON-Tuberculosis Gold In-Tube test were both performed simultaneously and their results were compared Using SPSS 12. Out of 34 subjects, 20(58.8%) had a positive tuberculin skin test, and 7(20.6%) had a positive QuantiFERON-Tuberculosis Gold In-Tube test. The two tests agreed in only 15(44.1%) cases and disagreed in 19(55.9%). In 16(47.1%) subjects, the QuantiFERON-Tuberculosis Gold In-Tube test was negative and tuberculin skin testwas positive, while in 3(8.8%) participants QuantiFERON-Tuberculosis Gold In-Tube test was positive and tuberculin skin test was negative. Kappa test revealed discordance between the two tests (k=-0.13; p=0.92). Latent tuberculosis infection prevalence was higher based on tuberculin skin test than QuantiFERON-Tuberculosis Gold In-Tube test. The results of the two tests were discordant.

  9. Thermal record of the test tubes method used for small fibers assessment

    Directory of Open Access Journals (Sweden)

    Denny D. Collina

    2011-12-01

    Full Text Available In Brazil, the test that uses test tubes filled with cold water (25ºC and tubes filled with water heated to a temperature of 45ºC is recommended by the Ministry of Health as a way of evaluate thermal sensitivity on the injured skin of leprosy patients. The purpose of this work was to quantify the thermal stimulation applied to the skin, as well as the temperature variation of the heated water and of the tube's outer surface during stimulation sessions. The experiment had the participation of 14 healthy volunteers (31.2±11.4 years-old, ten of which were male (33.1±13.5 years-old and four were female (26.5±4.7 years-old. Three consecutive stimulation sessions were carried out, each of them with four stimuli. The maximum skin temperature at the end of the stimuli was measured at 35.8±0.6ºC. Such temperature values may be useful in the assessment of the loss of small fibers, which are responsible for the sensation of warmth.

  10. Long term testing of materials for tube shielding, stage 2; Laangtidsprovning av tubskyddsmaterial, etapp 2

    Energy Technology Data Exchange (ETDEWEB)

    Norling, Rikard; Hjoernhede, Anders; Mattsson, Mattias

    2012-02-15

    temperature. It varies from a few months to several years. The cost of replacing tube shielding is significant, which calls for improved materials. In a previous study [1] various materials have been tested in the WtE CFB-boiler P14 at Haendeloe in Norrkoeping, Sweden. The study showed that several materials may be cost effective candidates for replacing 253MA, but the test period was too short for safe predictions. This work includes exposures at the same position, but with extended test period up to almost 12000 h to verify the previous results. In addition results from exposures in the WtE CFB-boiler Hoegdalen P6 in Stockholm, Sweden is included. This boiler suffers in particular from severe erosion of the tube shielding requiring it to be exchanged every few months

  11. Standard practice for ultrasonic testing of the Weld Zone of welded pipe and tubing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice describes general ultrasonic testing procedures for the detection of discontinuities in the weld and adjacent heat affected zones of welded pipe and tubing by scanning with relative motion between the search unit and pipe or tube. When contact or unfocused immersion search units are employed, this practice is intended for tubular products having specified outside diameters ≥2 in. (≥50 mm) and specified wall thicknesses of 1/8to 11/16 in. (3 to 27 mm). When properly focused immersion search units are employed, this practice may also be applied to material of smaller diameter and thinner wall. Note 1—When contact or unfocused immersion search units are used, precautions should be exercised when examining pipes or tubes near the lower specified limits. Certain combinations of search unit size, frequency, thin–wall thicknesses, and small diameters could cause generation of unwanted sound waves that may produce erroneous examination results. 1.2 All surfaces of material to be examined in ...

  12. A focused liquid jet formed by a water hammer in a test tube

    CERN Document Server

    Kiyama, Akihito; Ando, Keita; Kameda, Masaharu

    2015-01-01

    We investigate motion of a gas-liquid interface in a test tube induced by a large acceleration via impulsive force. We conduct simple experiments in which the tube partially filled with a liquid falls under gravity and impacts a rigid floor. A curved gas-liquid interface inside the tube reverses and eventually forms an elongated jet (i.e. the so-called a focused jet). In our experiments, there arises either vibration of the interface or increment in the velocity of a liquid jet accompanied by the onset of cavitation in the liquid column. These phenomena cannot be explained by considering pressure impulse in a classical potential flow analysis, which does not account for finite speeds of sound as well as phase change. Here we model such water-hammer events as a result of one-dimensional pressure wave propagation and its interaction with boundaries through acoustic impedance mismatching. The method of characteristics is applied to describe pressure wave interactions and the subsequent cavitation. The proposed m...

  13. Improvement of the tube diffusion test with respect to detection of antibiotic residues and sulphonamides in raw milk

    NARCIS (Netherlands)

    Nouws, J.F.M.; Loeffen, G.; Schouten, J.; Egmond, van H.; Keukens, H.; Stegeman, H.

    1995-01-01

    Improvements in detection of tetracycline, sulphonamide, macrolide, rifamycin, trimethoprim and aminoglycoside residues in milk were achieved by addition of either chloramphenicol or trimethoprim, and phenylbutazone to tube diffusion tests utilising Bacillus stearothermophilus var. calidolactis as b

  14. Improvement of the tube diffusion test with respect to detection of antibiotic residues and sulphonamides in raw milk

    NARCIS (Netherlands)

    Nouws, J.F.M.; Loeffen, G.; Schouten, J.; Egmond, van H.; Keukens, H.; Stegeman, H.

    1995-01-01

    Improvements in detection of tetracycline, sulphonamide, macrolide, rifamycin, trimethoprim and aminoglycoside residues in milk were achieved by addition of either chloramphenicol or trimethoprim, and phenylbutazone to tube diffusion tests utilising Bacillus stearothermophilus var. calidolactis as b

  15. Crack growth of throughwall flaw in Alloy 600 tube during leak testing

    Energy Technology Data Exchange (ETDEWEB)

    Bahn, Chi Bum, E-mail: bahn@pusan.ac.kr [Pusan National University, 2 Busandaehak-ro 63beon-gil, Geumjeong-gu, Busan 609-735 (Korea, Republic of); Majumdar, Saurin [Argonne National Laboratory, Lemont, IL 60439 (United States)

    2015-04-01

    Graphical abstract: - Highlights: • A series of leak testing was conducted at a constant pressure and room temperature. • The time-dependent increase in the leak rate was observed. • The fractography revealed slip offsets and crystallographic facets. • Time-dependent plasticity at the crack tip caused the slip offsets. • Fatigue by jet/structure interaction caused the crystallographic facets. - Abstract: We examined the issue of whether crack growth in a full thickness material can occur in a leaking crack. A series of leak tests was conducted at a room temperature and constant pressure (17.3 MPa) with Alloy 600 tube specimens containing a tight rectangular throughwall axial fatigue crack. To exclude a potential pulsation effect by a high pressure pump, the test water was pressurized by using high pressure nitrogen gas. Fractography showed that crack growth in the full thickness material can occur in the leaking crack by two mechanisms: time-dependent plasticity at the crack tip and fatigue induced by jet/structure interaction. The threshold leak rate at which the jet/structure interaction was triggered was between 1.3 and 3.3 L/min for the specific heat of the Alloy 600 tube tested.

  16. Bunched beam test of the CMS drift tubes local muon trigger

    CERN Document Server

    Arce, P; Benettoni, M; Benvenuti, A C; Bonacorsi, D; Bontenackels, M; Caballero, J; Cafaro, V; Capiluppi, P; Castellani, L; Cavallo, F R; Cerrada, M; Checchia, P; Colino, N; Conti, E; Corvo, M; de la Cruz, B; Dal Corso, F; Dallavalle, G M; De Giorgi, M; Fabbri, F; Fanfani, A; Fernández, C; Fernández de Troconiz, J; Fouz-Iglesias, M C; García-Abia, P; Gasparini, F; Gasparini, U; Giacomelli, P; Giordano, V; Gonella, F; Grandi, C; Guiducci, L; Gulmini, M; Hebbeker, T; Hernández, J M; Höpfner, K; Josa-Mutuberria, I; Lacaprara, S; Lippi, I; Mameghani, R; Marcellini, S; Maron, G; Martinelli, R; Maselli, S; Masetti, G; Meneguzzo, Anna Teresa; Meng, G; Monaco, V; Montanari, A; Montecassiano, F; Navarria, Francesco Luigi; Odorici, F; Passaseo, M; Pegoraro, M; Peroni, C; Perrotta, A; Ponte-Sancho, A J; Puerta, J; Reithler, H; Romero, A; Romero, L; Ronchese, P; Rossi, A; Rovelli, T; Sacchi, R; Staiano, A; Toniolo, N; Torassa, E; Torromeo, G; Travaglini, R; Vanini, S; Ventura, L; Ventura, Sandro; Villanueva, C; Willmott, C; Zanetti, M; Zangrando, L; Zotto, P L; Zumerle, G

    2004-01-01

    The 40 MHz bunched muon beam set up at CERN was used in May 2003 to make a full test of the drift tubes local muon trigger. The main goal of the test was to prove that the integration of the various devices located on a muon chamber was adequately done both on the hardware and software side of the system. Furthermore the test provided complete information about the general performance of the trigger algorithms in terms of efficiency and noise. Data were collected with the default configuration of the trigger devices and with several alternative configurations at various angles of incidence of the beam. Tests on noise suppression and di-muon trigger capability were performed.

  17. Performance of the CMS 2S $p_T$ module prototype using CBC2 readout at beam tests

    CERN Document Server

    Roy Chowdhury, Suvankar

    2017-01-01

    As the LHC will enter into its high luminosity phase\\,(HL-LHC), operating at a luminosity of $5\\rm{\\mbox{-}}7.5\\times10^{34}~\\rm cm^{-2}\\rm s^{-1}$, the CMS experiment will replace the Run 2 tracker with a new one which will be able to sustain the increased number of collisions per bunch crossing, which can be as high as 200. The tracker information will be used in the Level-1 trigger to reject low $p_T$ tracks. In this paper, the performance of the modules of the proposed outer tracker in test beams is reported.

  18. Development of a sealing process of capsules for surveillance test tubes of the vessel in nuclear power plants; Desarrollo de proceso de sellado de capsulas para probetas de vigilancia de la vasija en nucleoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Romero C, J.; Fernandez T, F.; Perez R, N.; Rocamontes A, M.; Garcia R, R. [ININ, Km 36.5 Carretera Mexico-Toluca, 52750 La Marquesa, Estado de Mexico (Mexico)

    2007-07-01

    The surveillance capsule is composed by the support, three capsules for impact test tubes, five capsules for tension test tubes and one porta dosemeters. The capsules for test tubes are of two types: rectangular capsule for Charpy test tubes and cylindrical capsule for tension test tubes. This work describes the development of the welding system to seal the capsules for test tubes that should contain helium of ultra high purity to a pressure of 1 atmosphere. (Author)

  19. Heat-transfer tests of aqueous ethylene glycol solutions in an electrically heated tube

    Science.gov (United States)

    Bernardo, Everett; Eian, Carroll S

    1945-01-01

    As part of an investigation of the cooling characteristics of liquid-cooled engines, tests were conducted with an electrically heated single-tube heat exchanger to determine the heat-transfer characteristics of an-e-2 ethylene glycol and other ethylene glycol-water mixtures. Similar tests were conducted with water and commercial butanol (n-butyl alcohol) for check purposes. The results of tests conducted at an approximately constant liquid-flow rate of 0.67 pound per second (Reynolds number, 14,500 to 112,500) indicate that at an average liquid temperature 200 degrees f, the heat-transfer coefficients obtained using water, nominal (by volume) 30 percent-70 percent and 70 percent-30 percent glycol-water mixtures are approximately 3.8, 2.8, and 1.4 times higher, respectively, than the heat-transfer coefficients obtained using an-e-2 ethylene glycol.

  20. Application of automatic inspection system to nondestructive test of heat transfer tubes of primary pressurized water cooler in the high temperature engineering test reactor. Joint research

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Takeshi; Furusawa, Takayuki [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Miyamoto, Satoshi [Japan Atomic Power Company, Tokyo (Japan)

    2001-07-01

    Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructive test of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructive test results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which were obtained for the heat transfer tube of the PPWC, were different from those obtained for the artificially defected tube. In UT echo amplitude of the PPWC tubes inspected was lower than 20% of distance-amplitude calibration curve. Thus, it was confirmed that there was no defect in depth, which was more than the detecting standard of the probes, on the outer surface of the heat transfer tubes of the PPWC inspected. (author)

  1. Cumulative damage fatigue tests on nuclear reactor Zircaloy-2 fuel tubes at room temperature and 300°C

    Science.gov (United States)

    Pandarinathan, P. R.; Vasudevan, P.

    1980-06-01

    Cumulative damage fatigue tests were conducted on the Zircaloy-2 fuel tubes at room temperature and 300°C on the modified Moore type, four-point-loaded, deflection-controlled, rotating bending fatigue testing machine. The cumulative cycle ratio at fracture for the Zircaloy-2 fuel tubes was found to depend on the sequence of loading, stress history, number of cycles of application of the pre-stress and the test temperature. A Hi-Lo type fatigue loading was found to be very much damaging at room temperature and this feature was not observed in the tests at 300°C. Results indicate significant differences in damage interaction and damage propagation under cumulative damage tests at room temperature and at 300°C. Block-loading fatigue tests are suggested as the best method to determine the life-time of Zircaloy-2 fuel tubes under random fatigue loading during their service in the reactor.

  2. Description and results of a two-dimensional lattice physics code benchmark for the Canadian Pressure Tube Supercritical Water-cooled Reactor (PT-SCWR)

    Energy Technology Data Exchange (ETDEWEB)

    Hummel, D.W.; Langton, S.E.; Ball, M.R.; Novog, D.R.; Buijs, A., E-mail: hummeld@mcmaster.ca [McMaster Univ., Hamilton, Ontario (Canada)

    2013-07-01

    Discrepancies have been observed among a number of recent reactor physics studies in support of the PT-SCWR pre-conceptual design, including differences in lattice-level predictions of infinite neutron multiplication factor, coolant void reactivity, and radial power profile. As a first step to resolving these discrepancies, a lattice-level benchmark problem was designed based on the 78-element plutonium-thorium PT-SCWR fuel design under a set of prescribed local conditions. This benchmark problem was modeled with a suite of both deterministic and Monte Carlo neutron transport codes. The results of these models are presented here as the basis of a code-to-code comparison. (author)

  3. Laser Cut Nitinol Tubing Fatigue Coupon: Design, Testing, and Endurance Limit

    Science.gov (United States)

    Forcucci, Stephen J.

    2014-07-01

    Nitinol medical device implants made from a laser cut tubing process (i.e., stents, valve structures, etc.) frequently require a fatigue durability assessment, which necessitates determining the material fatigue properties. Towards the goal of determining the strain-based endurance limit of medical grade superelastic Nitinol tubing, a coupon was designed and evaluated via FEA using Abaqus software, produced via laser cutting, shape setting, and electro-polishing processes, and then fatigue tested to 10 million cycles. FEA was used to determine the strain versus alternating displacement amplitude for the coupon. Error due to dimensional tolerances was determined. The coupons were then fatigue tested in a 37 °C temperature deionized water bath at alternating strain levels ranging from 0.75 to 4.0% at zero mean strain. Sample replication was greater than 90%, and the median alternating strain fatigue limit was determined via two methods. Confidence and reliability with maximum likelihood statistics are used to present a strain-based endurance limit for the material. The results seem to differ from previous published values.

  4. Fireside corrosion testing of candidate superheater tube alloys, coatings, and claddings - phase II

    Energy Technology Data Exchange (ETDEWEB)

    Blough, J.L.; Stanko, G.J. [Foster Wheeler Development Corp., Livingston, NJ (United States)

    1996-08-01

    In Phase I a variety of developmental and commercial tubing alloys and claddings were exposed to laboratory fireside corrosion testing simulating a superheater or reheater in a coal-fired boiler. Phase II (in situ testing) has exposed samples of 347, RA-8511, HR3C, 253MA, Fe{sub 3}Al + 5Cr, 310 modified, 800HT, NF 709, 690 clad, and 671 clad for over 10,000 hours to the actual operating conditions of a 250-MW coal-fired boiler. The samples were installed on an air-cooled, retractable corrosion probe, installed in the reheater cavity, and controlled to the operating metal temperatures of an existing and advanced-cycle coal-fired boiler. Samples of each alloy will be exposed for 4000, 12,000, and 16,000 hours of operation. The results will be presented for the metallurgical examination of the corrosion probe samples after 4000 hours of exposure.

  5. A method and sensor for the eddy current non destructive testing of thin tubes; Procede de controle non destructif d`un tube mince par courants de Foucault

    Energy Technology Data Exchange (ETDEWEB)

    Sartre, B.; Miller, D.; Placko, D.

    1995-06-02

    In order to control the wear (cracking or thinning) of vapor generator tubes, especially in PWR reactors, due to the friction between the tubes and dampers, an eddy current control system is proposed where the transducer is run through the tubes, and measures the tube wall thickness or tube-block clearance through impedance measurements, taking into account the variation of the sensor-to-tube distance. 8 fig.

  6. Shock tube design for high intensity blast waves for laboratory testing of armor and combat materiel

    Directory of Open Access Journals (Sweden)

    Elijah Courtney

    2014-06-01

    Full Text Available Shock tubes create simulated blast waves which can be directed and measured to study blast wave effects under laboratory conditions. It is desirable to increase available peak pressure from ∼1 MPa to ∼5 MPa to simulate closer blast sources and facilitate development and testing of personal and vehicle armors. Three methods are experimentally investigated to increase peak simulated blast pressure produced by an oxy-acetylene driven shock tube while maintaining suitability for laboratory studies. The first method is the addition of a Shchelkin spiral priming section which supports a deflagration to detonation transition. This approach increases the average peak pressure from 1.17 MPa to 5.33 MPa while maintaining a relevant pressure-time curve (near Friedlander waveform. The second method is a bottleneck between the driving and driven sections. Coupling a 79 mm diameter driving section to a 53 mm driven section increases the peak pressure from 1.17 MPa to 2.25 MPa. A 103 mm driving section is used to increase peak pressure to 2.64 MPa. The third method, adding solid fuel to the driving section with the oxy-acetylene, results in a peak pressure increasing to 1.70 MPa.

  7. Shock tube design for high intensity blast waves for laboratory testing of armor and combat materiel

    Institute of Scientific and Technical Information of China (English)

    Elijah COURTNEY; Amy COURTNEY; Michael COURTNEY

    2014-01-01

    Shock tubes create simulated blast waves which can be directed and measured to study blast wave effects under laboratory conditions. It is desirable to increase available peak pressure from w1 MPa to w5 MPa to simulate closer blast sources and facilitate development and testing of personal and vehicle armors. Three methods are experimentally investigated to increase peak simulated blast pressure produced by an oxy-acetylene driven shock tube while maintaining suitability for laboratory studies. The first method is the addition of a Shchelkin spiral prim-ing section which supports a deflagration to detonation transition. This approach increases the average peak pressure from 1.17 MPa to 5.33 MPa while maintaining a relevant pressure-time curve (near Friedlander waveform). The second method is a bottleneck between the driving and driven sections. Coupling a 79 mm diameter driving section to a 53 mm driven section increases the peak pressure from 1.17 MPa to 2.25 MPa. A 103 mm driving section is used to increase peak pressure to 2.64 MPa. The third method, adding solid fuel to the driving section with the oxy-acetylene, results in a peak pressure increasing to 1.70 MPa.

  8. Novel method for estimating the dynamic characteristics of pressure sensor in shock tube calibration test.

    Science.gov (United States)

    Li, Qiang; Wang, Zhongyu; Wang, Zhuoran; Yan, Hu

    2015-06-01

    A shock tube is usually used to excite the dynamic characteristics of the pressure sensor used in an aircraft. This paper proposes a novel estimation method for determining the dynamic characteristic parameters of the pressure sensor. A preprocessing operation based on Grey Model [GM(1,1)] and bootstrap method (BM) is employed to analyze the output of a calibrated pressure sensor under step excitation. Three sequences, which include the estimated value sequence, upper boundary, and lower boundary, are obtained. The processing methods on filtering and modeling are used to explore the three sequences independently. The optimal estimated, upper boundary, and lower boundary models are then established. The three models are solved, and a group of dynamic characteristic parameters corresponding to the estimated intervals are obtained. A shock tube calibration test consisting of two experiments is performed to validate the performance of the proposed method. The results show that the relative errors of the dynamic characteristic parameters of time and frequency domains do not exceed 9% and 10%, respectively. Moreover, the nominal and estimated values of the parameters fall into the estimated intervals limited by the upper and lower values.

  9. Shock Tube Design for High Intensity Blast Waves for Laboratory Testing of Armor and Combat Materiel

    CERN Document Server

    Courtney, Elijah; Courtney, Michael

    2015-01-01

    Shock tubes create simulated blast waves which can be directed and measured to study blast wave effects under laboratory conditions. It is desirable to increase available peak pressure from ~1 MPa to ~5 MPa to simulate closer blast sources and facilitate development and testing of personal and vehicle armors. Three methods were investigated to increase peak simulated blast pressure produced by an oxy-acetylene driven shock tube while maintaining suitability for laboratory studies. The first method is the addition of a Shchelkin spiral priming section which works by increasing the turbulent flow of the deflagration wave, thus increasing its speed and pressure. This approach increased the average peak pressure from 1.17 MPa to 5.33 MPa while maintaining a relevant pressure-time curve (Friedlander waveform). The second method is a bottleneck between the driving and driven sections. Coupling a 79 mm diameter driving section to a 53 mm driven section increased the peak pressure from 1.17 MPa to 2.25 MPa. Using a 1...

  10. Time-lapse cinematography of the capillary tube cell migration inhibition test.

    Science.gov (United States)

    Bray, M A

    1980-01-01

    The kinetics of human and guinea pig cell migration inhibition have been studied using time-lapse cinematography of cells migrating from capillary tubes. Guinea pig and human cells exhibit markedly different kinetics in the absence of inhibitors. Specific antigen causes a dose-related inhibition of migration for up to 60 h using guinea pig cells and a peak of inhibition after 18 h using the human leucocyte system. The timing of measurement of maximum activity more critical for the latter test. The kinetics of lymphokine generation have been examined and the migration inhibitory activity of the plant mitogen (PHA), a Kurloff cell product and a continuous cell line supernatant have been compared with the inhibitory profiles of lymphokine preparations and specific antigen.

  11. Comparison of manual mycobacteria growth indicator tube and epsilometer test with agar proportion method for susceptibility testing of Mycobacterium tuberculosis

    Directory of Open Access Journals (Sweden)

    N Karabulut

    2014-01-01

    Full Text Available Background and Objectives: Antimycobacterial susceptibility tests take weeks, and delayed therapy can lead to spread of Mycobacterium tuberculosis. Therefore, rapid, accurate and cost-effective methods are required for proper therapy selection. In this study, the Mycobacteria growth indicator tube (MGIT and epsilometer test (Etest methods were compared to the agar proportion method for susceptibility testing of Mycobacterium tuberculosis. Materials and Methods: The susceptibility tests against isoniazid (INH, rifampin (RIF, streptomycin (STM and ethambutol (ETM of 51 M. tuberculosis complex isolates were analyzed by the MGIT, Etest and agar proportion methods. Results: The concordance between MGIT/Etest and agar proportion methods was 98% for INH and 100% for RIF, STM, ETM. There were not statistically significant differences in results of the susceptibility tests between MGIT/Etest and the reference agar proportion method. Conclusion: The results have shown that MGIT and Etest methods can be used instead of the agar proportion method, because these two methods are more rapid and easier than the agar proportion method.

  12. Evaluation of a short glass fibre-reinforced tube as a model for cat femur for biomechanical testing of orthopaedic implants.

    Science.gov (United States)

    Gibson, T W G; Moens, N M M; Runciman, R J; Holmberg, D L

    2008-01-01

    The biomechanical testing of tubes made of third generation short glass fibre-reinforced (SGFR) material approximating cat femurs was performed in order to determine their suitability as cat femur surrogates for the biomechanical testing of orthopaedic implants. The tubes were tested in compression, three-point bending, notch testing, and screw pullout. Thin walled (B1-tubes) had a 13% lower maximum load to failure, a 19% higher maximum strength and a 13% lower elastic modulus compared to cat femurs tested in compression. B1-tubes maximum load to failure in three-point bending and screw pullout strength were considerably lower compared to cat femurs (29% and 63%, respectively). Notch testing was not performed on B1-tubes due to low bending strength. Thicker walled (B2-tubes) had a 23% higher maximum load to failure, a 10% higher maximum strength and a 21% lower elastic modulus compared to cat femurs tested in compression. The comparison of B2-tubes and cat femurs in three-point bending revealed a 7% increase in maximum load to failure for the B2-tubes. Drilled B2-tubes (notch testing) were weaker with a 30% lower load to failure compared to cat femurs. A screw pullout comparison of B2-tubes and cat femurs revealed a 2% increase in maximum load to failure for the B2-tubes. These tubes were intended to provide a model as a suitable surrogate for cat femurs for testing the bending strength of various orthopaedic constructs involving plates and screws. Testing revealed that third generation SGFR tubes were not suitable for these purposes and emphasizes the need to carefully evaluate the suitability of any model.

  13. Forced Convection Boiling and Critical Heat Flux of Ethanol in Electrically Heated Tube Tests

    Science.gov (United States)

    Meyer, Michael L.; Linne, Diane L.; Rousar, Donald C.

    1998-01-01

    Electrically heated tube tests were conducted to characterize the critical heat flux (transition from nucleate to film boiling) of subcritical ethanol flowing at conditions relevant to the design of a regeneratively cooled rocket engine thrust chamber. The coolant was SDA-3C alcohol (95% ethyl alcohol, 5% isopropyl alcohol by weight), and tests were conducted over the following ranges of conditions: pressure from 144 to 703 psia, flow velocities from 9.7 to 77 ft/s, coolant subcooling from 33 to 362 F, and critical heat fluxes up to 8.7 BTU/in(exp 2)/sec. For the data taken near 200 psia, critical heat flux was correlated as a function of the product of velocity and fluid subcooling to within +/- 20%. For data taken at higher pressures, an additional pressure term is needed to correlate the critical heat flux. It was also shown that at the higher test pressures and/or flow rates, exceeding the critical heat flux did not result in wall burnout. This result may significantly increase the engine heat flux design envelope for higher pressure conditions.

  14. Fast and Accurate Non-destructive Testing System for Inspection of Canning Tubes

    DEFF Research Database (Denmark)

    Gundtoft, Hans Erik; Nielsen, E.

    1973-01-01

    The authors describe the development of an inspection bench for the non-destructive examination of canning tubes. The bench is original in that the internal diameter is calculated from exact measurement of the outer diameter and the wall thickness. The transducers for inspection and control...... are rotated around the tube. Thus all measurements are made externally to the tube. The result of these inovations is that non-destructive examination can be made in a single pass of the tube, and the assessment is more accurate, economical, and faster than that possible with existing techniques....

  15. Some important aspects in testing high-modulus fiber composite tubes designed for multiaxial loading.

    Science.gov (United States)

    Sullivan, T. L.; Chamis, C. C.

    1972-01-01

    Tubular specimens were potted in metal grips to determine the feasibility of this gripping method in applying multiaxial loads. Strain gage rosettes were used to assess grip transitional strains, through thickness strain variation and strain variations along the tube length and circumference. The investigation was limited to loading 0, 45, plus or minus 45, and 90 deg graphite/epoxy and glass/epoxy tubes in axial tension. Results include modifications made to the grips to reduce transitional strains, illustrations of the tube failure modes, and some material properties. The gripping concept shows promise as a satisfactory technique for applying multiaxial loads to high-strength, high-modulus fiber composite tubes.

  16. Sex in a test tube: testing the benefits of in vitro recombination.

    Science.gov (United States)

    Pesce, Diego; Lehman, Niles; de Visser, J Arjan G M

    2016-10-19

    The origin and evolution of sex, and the associated role of recombination, present a major problem in biology. Sex typically involves recombination of closely related DNA or RNA sequences, which is fundamentally a random process that creates but also breaks up beneficial allele combinations. Directed evolution experiments, which combine in vitro mutation and recombination protocols with in vitro or in vivo selection, have proved to be an effective approach for improving functionality of nucleic acids and enzymes. As this approach allows extreme control over evolutionary conditions and parameters, it also facilitates the detection of small or position-specific recombination benefits and benefits associated with recombination between highly divergent genotypes. Yet, in vitro approaches have been largely exploratory and motivated by obtaining improved end products rather than testing hypotheses of recombination benefits. Here, we review the various experimental systems and approaches used by in vitro studies of recombination, discuss what they say about the evolutionary role of recombination, and sketch their potential for addressing extant questions about the evolutionary role of sex and recombination, in particular on complex fitness landscapes. We also review recent insights into the role of 'extracellular recombination' during the origin of life.This article is part of the themed issue 'Weird sex: the underappreciated diversity of sexual reproduction'.

  17. PENERAPAN KEBIJAKAN PENJADWALAN ULANG PADA RUANG LINGKUP SINGLE MACHINE UNTUK MEMINIMASI TOTAL TARDINESS (Studi Kasus di PT. Indonesia Steel Tube Works

    Directory of Open Access Journals (Sweden)

    Denny Nurkertamanda

    2012-02-01

    Full Text Available Customer satisfaction is the most important thing to be considered to keep the customer trust of a productor even of a company. Giving the satisfaction to the customer can be achieved by several ways and on timedelivery product is one of them. It is true that some problems can often occur during that achievement andmay hinder the on time delivery fulfillment. One of the major elements that hold the key role of on timedelivery fulfillment is production scheduling. The implementation of appropriate production schedulingpolicy will determine the accomplishment of on time delivery fulfillment in some ways. This statement isalso works for Indonesia Steel Tube Works Ltd., as a company that always cares about the customersatisfaction on quality and on time delivery. If we observe the production scheduling records of IndonesiaSteel Tube Works Ltd. we can find some lateness problems that in some case happened in an extensiveinterval of tardiness. The company only runs the production scheduling based on the group of pipediameter. This policy seems cannot well handle the rush orders that often emerge on every schedulingperiod and effect in tardiness problems. The company needs to consider the rescheduling policy with theaim of reducing the tardiness that often emerges because of the rush order disruption.

  18. Fluid-Elastic Instability Tests on Parallel Triangular Tube Bundles with Different Mass Ratio Values under Increasing and Decreasing Flow Velocities

    Directory of Open Access Journals (Sweden)

    Xu Zhang

    2016-01-01

    Full Text Available To study the effects of increasing and decreasing flow velocities on the fluid-elastic instability of tube bundles, the responses of an elastically mounted tube in a rigid parallel triangular tube bundle with a pitch-to-diameter ratio of 1.67 were tested in a water tunnel subjected to crossflow. Aluminum and stainless steel tubes were tested, respectively. In the in-line and transverse directions, the amplitudes, power spectrum density functions, response frequencies, added mass coefficients, and other results were obtained and compared. Results show that the nonlinear hysteresis phenomenon occurred in both tube bundle vibrations. When the flow velocity is decreasing, the tubes which have been in the state of fluid-elastic instability can keep on this state for a certain flow velocity range. During this process, the response frequencies of the tubes will decrease. Furthermore, the response frequencies of the aluminum tube can decrease much more than those of the stainless steel tube. The fluid-elastic instability constants fitted for these experiments were obtained from experimental data. A deeper insight into the fluid-elastic instability of tube bundles was also obtained by synthesizing the results. This study is beneficial for designing and operating equipment with tube bundles inside, as well as for further research on the fluid-elastic instability of tube bundles.

  19. Integrated testing of the Thales LPT9510 pulse tube cooler and the iris LCCE electronics

    Science.gov (United States)

    Johnson, Dean L.; Rodriguez, Jose I.; Carroll, Brian A.; Bustamante, John G.; Kirkconnell, Carl S.; Luong, Thomas T.; Murphy, J. B.; Haley, Michael F.

    2014-01-01

    The Jet Propulsion Laboratory (JPL) has identified the Thales LPT9510 pulse tube cryocooler as a candidate low cost cryocooler to provide active cooling on future cost-capped scientific missions. The commercially available cooler can provide refrigeration in excess of 2 W at 100K for 60W of power. JPL purchased the LPT9510 cooler for thermal and dynamic performance characterization, and has initiated the flight qualification of the existing cooler design to satisfy near-term JPL needs for this cooler. The LPT9510 has been thermally tested over the heat reject temperature range of 0C to +40C during characterization testing. The cooler was placed on a force dynamometer to measure the selfgenerated vibration of the cooler. Iris Technology has provided JPL with a brass board version of the Low Cost Cryocooler Electronics (LCCE) to drive the Thales cooler during characterization testing. The LCCE provides precision closed-loop temperature control and embodies extensive protection circuitry for handling and operational robustness; other features such as exported vibration mitigation and low frequency input current filtering are envisioned as options that future flight versions may or may not include based upon the mission requirements. JPL has also chosen to partner with Iris Technology for the development of electronics suitable for future flight applications. Iris Technology is building a set of radiation-hard, flight-design electronics to deliver to the Air Force Research Laboratory (AFRL). Test results of the thermal, dynamic and EMC testing of the integrated Thales LPT9510 cooler and Iris LCCE electronics is presented here.

  20. Integrated testing of the Thales LPT9510 pulse tube cooler and the iris LCCE electronics

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Dean L.; Rodriguez, Jose I.; Carroll, Brian A. [The Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 (United States); Bustamante, John G. [Georgia Institute of Technology, Atlanta, GA 30332 (United States); Kirkconnell, Carl S.; Luong, Thomas T.; Murphy, J. B.; Haley, Michael F. [Iris Technology, Irvine, CA 92616 (United States)

    2014-01-29

    The Jet Propulsion Laboratory (JPL) has identified the Thales LPT9510 pulse tube cryocooler as a candidate low cost cryocooler to provide active cooling on future cost-capped scientific missions. The commercially available cooler can provide refrigeration in excess of 2 W at 100K for 60W of power. JPL purchased the LPT9510 cooler for thermal and dynamic performance characterization, and has initiated the flight qualification of the existing cooler design to satisfy near-term JPL needs for this cooler. The LPT9510 has been thermally tested over the heat reject temperature range of 0C to +40C during characterization testing. The cooler was placed on a force dynamometer to measure the selfgenerated vibration of the cooler. Iris Technology has provided JPL with a brass board version of the Low Cost Cryocooler Electronics (LCCE) to drive the Thales cooler during characterization testing. The LCCE provides precision closed-loop temperature control and embodies extensive protection circuitry for handling and operational robustness; other features such as exported vibration mitigation and low frequency input current filtering are envisioned as options that future flight versions may or may not include based upon the mission requirements. JPL has also chosen to partner with Iris Technology for the development of electronics suitable for future flight applications. Iris Technology is building a set of radiation-hard, flight-design electronics to deliver to the Air Force Research Laboratory (AFRL). Test results of the thermal, dynamic and EMC testing of the integrated Thales LPT9510 cooler and Iris LCCE electronics is presented here.

  1. Fireside corrosion testing of candidate superheater tube alloys, coatings, and claddings -- Phase 2

    Energy Technology Data Exchange (ETDEWEB)

    Blough, J.L.; Seitz, W.W. [Foster Wheeler Development Corp., Livingston, NJ (United States)

    1997-12-01

    In Phase 1 a variety of developmental and commercial tubing alloys and claddings were exposed to laboratory fireside corrosion testing simulating a superheater or reheater in a coal-fired boiler. Phase 2 (in situ testing) has exposed samples of 347 RA-85H, HR3C, 253MA, Fe{sub 3}Al + 5Cr, 310 Ta modified, NF 709, 690 clad, and 671 clad for approximately 4,000, 12,000, and 16,000 hours to the actual operating conditions of a 250-MW coal-fired boiler. The samples were assembled on an air-cooled, retractable corrosion probe, the probe was installed in the reheater activity of the boiler and controlled to the operating metal temperatures of an existing and advanced-cycle coal-fired boiler. The results will be presented for the preliminary metallurgical examination of the corrosion probe samples after 16,000 hours of exposure. Continued metallurgical and interpretive analysis is still on going.

  2. 49 CFR 40.245 - What is the procedure for an alcohol screening test using a saliva ASD or a breath tube ASD?

    Science.gov (United States)

    2010-10-01

    ... test using a saliva ASD or a breath tube ASD? 40.245 Section 40.245 Transportation Office of the... Alcohol Screening Tests § 40.245 What is the procedure for an alcohol screening test using a saliva ASD or a breath tube ASD? (a) As the STT or BAT, you must take the following steps when using the...

  3. Design, analysis and testing of the Optical Tube Assemblies for the ESO VLT Four Laser Guide Star Facility

    NARCIS (Netherlands)

    Henselmans, R.; Nijkerk, M.D.; Lemmen, M.H.J.; Rijnveld, N.; Kamphues, F.G.

    2012-01-01

    TNO has developed the Optical Tube Assemblies (OTAs) for the ESO VLT Four Laser Guide Star Facility. The OTAs are Galilean 20x beam expanders, expanding a ∅15 mm input beam (25W, 589 nm CW) to a steerable ∅300 mm output beam. TNO has recently successfully completed acceptance testing of the four uni

  4. Bit-error-rate testing of high-power 30-GHz traveling-wave tubes for ground-terminal applications

    Science.gov (United States)

    Shalkhauser, Kurt A.

    1987-01-01

    Tests were conducted at NASA Lewis to measure the bit-error-rate performance of two 30-GHz 200-W coupled-cavity traveling-wave tubes (TWTs). The transmission effects of each TWT on a band-limited 220-Mbit/s SMSK signal were investigated. The tests relied on the use of a recently developed digital simulation and evaluation system constructed at Lewis as part of the 30/20-GHz technology development program. This paper describes the approach taken to test the 30-GHz tubes and discusses the test data. A description of the bit-error-rate measurement system and the adaptations needed to facilitate TWT testing are also presented.

  5. Field survey and laboratory tests on composite materials case of GRP (Glass Fiber Reinforced Polyester tubes for water suply

    Directory of Open Access Journals (Sweden)

    Radu Hariga

    2013-09-01

    Full Text Available In the Moldova land, were made two lines of water adduction, having 6000 m length and 40 m slope, or 1/150 slope. The water supply component tubes were disposed under the plant: The tubes are made of glass – reinforced thermosetting plastics (GRP. After about 180 days of operation, one of the lines showed severe deterioration of the quality pipe components. This paper deals with some laboratory tests in order to detect the failure cases of the pipelines components.

  6. Simulated heat-exchanger tubes: DOE Geothermal Test Facility, East Mesa, California. Corrosion test report. [Allegheny-Ludlum Alloy 29-4 and Alloy 29-4C

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, P.F. II; Anliker, D.M.

    1982-11-01

    A 1032-hr corrosion test was made of two geothermal heat exchanger materials, Allegheny-Ludlum Alloy 29-4 and Alloy 29-4C. Coupons of the two metals were exposed under conditions simulating flow in a geothermal heat exchanger tube. Continuous flow and cyclic exposure tests were made. No signs of localized corrosion were observed in either the base metal, tube weld seam, or heat affected zone. Most coupons showed statistically insignificant weight change. A corrosion rate of less than 0.5 mil/yr is indicated. No significant difference in the performance of the two alloys is reported. (LEW)

  7. Construction and test of high precision drift-tube (sMDT) chambers for the ATLAS muon spectrometer

    CERN Document Server

    Nowak, Sebastian; Kroha, Hubert; Schwegler, Philipp; Sforza, Federico

    2014-01-01

    For the upgrade of the ATLAS muon spectrometer in March 2014 new muon tracking chambers (sMDT) with drift-tubes of 15 mm diameter, half of the value of the standard ATLAS Monitored Drift-Tubes (MDT) chambers, and 10~$\\mu$m positioning accuracy of the sense wires have been constructed. The new chambers are designed to be fully compatible with the present ATLAS services but, with respect to the previously installed ATLAS MDT chambers, they are assembled in a more compact geometry and they deploy two additional tube layers that provide redundant rack information. The chambers are composed of 8 layers of in total 624 aluminium drift-tubes. The assembly of a chamber is completed within a week. A semi-automatized production line is used for the assembly of the drift-tubes prior to the chamber assembly. The production procedures and the quality control tests of the single components and of the complete chambers will be discussed. The wire position in the completed chambers have been measured by using a coordinate me...

  8. Fireside corrosion testing of candidate superheater tube alloys, coatings, and claddings - Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Blough, J.L.; Krawchuk, M.T.; Van Weele, S.F. [Foster Wheeler Development Corp., Livingston, NJ (United States)

    1995-08-01

    A number of developmental and commercial tubing alloys and claddings have previously been exposed in Phase I to laboratory fireside corrosion testing simulating a superheater or reheater in a coal-fired boiler. This program is exposing samples of TP 347, RA-85H, HR-3C, 253MA, Fe{sub 3}Al + 5Cr, 310 modified, NF-709, 690 clad, and 671 clad, which showed good corrosion resistance from Phase 1, to the actual operating conditions of a 250-MW, coal-fired boiler. The samples were installed on air-cooled, retractable corrosion probes, installed in the reheater cavity, and are being controlled to the operating metal temperatures of an existing and advanced-cycle coal-fired boiler. The exposure will continue for 4000, 12,000, and 16,000 hours of operation. After the three exposure times, the samples will be metallurgically examined to determine the wastage rates and mode of attack. The probes were commissioned November 16, 1994. The temperatures are being recorded every 15 minutes, and the weighted average temperature calculated for each sample. Each of the alloys is being exposed to a temperature in each of two temperature bands-1150 to 1260{degrees}F and 1260 to 1325{degrees}F. After 2000 hours of exposure, one of the corrosion probes was cleaned and the wall thicknesses were ultrasonically measured. The alloy performance from the field probes will be discussed.

  9. Comparison of pneumatic tube system with manual transport for routine chemistry, hematology, coagulation and blood gas tests.

    Science.gov (United States)

    Pupek, Alex; Matthewson, Beverly; Whitman, Erin; Fullarton, Rachel; Chen, Yu

    2017-08-28

    The pneumatic tube system (PTS) is commonly used in modern clinical laboratories to provide quick specimen delivery. However, its impact on sample integrity and laboratory testing results are still debatable. In addition, each PTS installation and configuration is unique to its institution. We sought to validate our Swisslog PTS by comparing routine chemistry, hematology, coagulation and blood gas test results and sample integrity indices between duplicate samples transported either manually or by PTS. Duplicate samples were delivered to the core laboratory manually by human courier or via the Swisslog PTS. Head-to-head comparisons of 48 routine chemistry, hematology, coagulation and blood gas laboratory tests, and three sample integrity indices were conducted on 41 healthy volunteers and 61 adult patients. The PTS showed no impact on sample hemolysis, lipemia, or icterus indices (all pgas (in syringe and capillary tube) laboratory tests.

  10. Field tests of a vertical-fluted-tube condenser in the prototype power plant at the Raft River Geothermal Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, R.W.

    1983-04-01

    A vertical-fluted-tube condenser was designed, fabricated, and tested with isobutane as the shell-side working fluid in a binary prototype power plant at the Raft River Geothermal Test Site. After shakedown and contamination removal operations were completed, the four-pass water-cooled unit (with 102 outside-fluted Admiralty tubes) achieved performance predictions while operating with the plant surface evaporator on-line. A sample comparison shows that use of this enhanced condenser concept offers the potential for a reduction of about 65% from the size suggested by corresponding designs using conventional horizontal-smooth-tube concepts. Subsequent substitution of a direct-contact evaporator for the surface evaporator brought drastic reductions in system performance, the apparent consequence of high concentrations of noncondensible gases introduced by the brine/working-fluid interaction.

  11. Radiative transfer with finite elements. Pt. 1. Basic method and tests

    Energy Technology Data Exchange (ETDEWEB)

    Richling, S. [Heidelberg Univ. (Germany). Inst. fuer Theoretische Astrophysik; Meinkoehn, E. [Heidelberg Univ. (Germany). Inst. fuer Theoretische Astrophysik]|[Heidelberg Univ. (Germany). Inst. fuer Angewandte Mathematik; Kryzhevoi, N. [Heidelberg Univ. (Germany). Inst. fuer Theoretische Astrophysik]|[Heidelberg Univ. (DE). Interdisziplinaeres Zentrum fuer Wissenschaftliches Rechnen (IWR); Kanschat, G. [Heidelberg Univ. (Germany). Inst. fuer Angewandte Mathematik]|[Heidelberg Univ. (DE). Interdisziplinaeres Zentrum fuer Wissenschaftliches Rechnen (IWR)

    2001-10-01

    A finite element method for solving the monochromatic radiation transfer equation including scattering in three dimensions is presented. The algorithm employs unstructured grids which are adaptively refined. Adaptivity as well as ordinate parallelization reduce memory requirements and execution time and make it possible to calculate the radiation field across several length scales for objects with strong opacity gradients. An a posteriori error estimate for one particular quantity is obtained by solving the dual problem. The application to a sample of test problems reveals the properties of the implementation. (orig.)

  12. Within-subject interlaboratory variability of QuantiFERON-TB gold in-tube tests.

    Directory of Open Access Journals (Sweden)

    William C Whitworth

    Full Text Available BACKGROUND: The QuantiFERON®-TB Gold In-Tube test (QFT-GIT is a viable alternative to the tuberculin skin test (TST for detecting Mycobacterium tuberculosis infection. However, within-subject variability may limit test utility. To assess variability, we compared results from the same subjects when QFT-GIT enzyme-linked immunosorbent assays (ELISAs were performed in different laboratories. METHODS: Subjects were recruited at two sites and blood was tested in three labs. Two labs used the same type of automated ELISA workstation, 8-point calibration curves, and electronic data transfer. The third lab used a different automated ELISA workstation, 4-point calibration curves, and manual data entry. Variability was assessed by interpretation agreement and comparison of interferon-γ (IFN-γ measurements. Data for subjects with discordant interpretations or discrepancies in TB Response >0.05 IU/mL were verified or corrected, and variability was reassessed using a reconciled dataset. RESULTS: Ninety-seven subjects had results from three labs. Eleven (11.3% had discordant interpretations and 72 (74.2% had discrepancies >0.05 IU/mL using unreconciled results. After correction of manual data entry errors for 9 subjects, and exclusion of 6 subjects due to methodological errors, 7 (7.7% subjects were discordant. Of these, 6 (85.7% had all TB Responses within 0.25 IU/mL of the manufacturer's recommended cutoff. Non-uniform error of measurement was observed, with greater variation in higher IFN-γ measurements. Within-subject standard deviation for TB Response was as high as 0.16 IU/mL, and limits of agreement ranged from -0.46 to 0.43 IU/mL for subjects with mean TB Response within 0.25 IU/mL of the cutoff. CONCLUSION: Greater interlaboratory variability was associated with manual data entry and higher IFN-γ measurements. Manual data entry should be avoided. Because variability in measuring TB Response may affect interpretation, especially near the cutoff

  13. Performance tests of a fast-acting valve for the driver tubes of a large blast/thermal simulator

    Science.gov (United States)

    Stacey, Marcela R.

    1992-05-01

    This document describes the testing of a fast-acting throat valve element designed by Eaton Consolidated Controls for use in driver tubes, (blast generators) of a Large Blast/Thermal Simulator (LB/TS). An LB/TS is used to simulate decaying blast waves such as are generated by nuclear explosions. The Eaton Throat Valve Element (ETVE) was tested at the Idaho National Engineering Laboratory (INEL) to evaluate its performance against the design criteria. The ETVE was mounted at the end of a driver tube and actuated 16 times at 6 different driver pressures ranging from 396 kPa to 12.4 MPa (57.5 psi to 1,800 psi). The valve seals survived successfully all 16 tests with the driver gas at room temperature and maintained an acceptable leak rate throughout the test program. The average valve lag time was determined to vary from 36 to 120 ms; however, the valve was found to chatter, going through several (up to 20) opening/closing cycles after actuation before settling in the open position. An increase in the pneumatic supply pressure driving the valve showed a minor decrease in the number of chattering cycles. When the valve was actuated with no pressure in the driver tube, no chattering was observed. At the conclusion of the test sequence, the valve seals were inspected and were in good condition. The shock waves appeared to agree with code predictions when the chattering effects were disregarded.

  14. Analysis, development and testing of a fixed tilt solar collector employing reversible Vee-Trough reflectors and vacuum tube receivers

    Science.gov (United States)

    Selcuk, M. K.

    1979-01-01

    The Vee-Trough/Vacuum Tube Collector (VTVTC) aimed to improve the efficiency and reduce the cost of collectors assembled from evacuated tube receivers. The VTVTC was analyzed rigorously and a mathematical model was developed to calculate the optical performance of the vee-trough concentrator and the thermal performance of the evacuated tube receiver. A test bed was constructed to verify the mathematical analyses and compare reflectors made out of glass, Alzak and aluminized GEB Teflon. Tests were run at temperatures ranging from 95 to 180 C during the months of April, May, June, July and August 1977. Vee-trough collector efficiencies of 35-40 per cent were observed at an operating temperature of about 175 C. Test results compared well with the calculated values. Test data covering a complete day are presented for selected dates throughout the test season. Predicted daily useful heat collection and efficiency values are presented for a year's duration at operation temperatures ranging from 65 to 230 C. Estimated collector costs and resulting thermal energy costs are presented. Analytical and experimental results are discussed along with an economic evaluation.

  15. The effects of transport by pneumatic tube system on blood cell count, erythrocyte sedimentation and coagulation tests

    OpenAIRE

    Koçak, Fatma Emel; Yöntem, Mustafa; Yücel, Özlem; Çilo, Mustafa; Genç, Özlem; Meral, Ayfer

    2013-01-01

    Introduction: Today, the pneumatic tube transport system (PTS) is used frequently because of its advantages related to timing and speed. However, the impact of various types of PTS on blood com-ponents is unknown. The aim of this study was to examine the influence of PTS on the quality of rou-tine blood cell counts, erythrocyte sedimentation, and certain blood coagulation tests. Materials and methods: Paired blood samples were obtained from each of 45 human volunteers and evaluated by bloo...

  16. Eddy current monitoring of fatigue crack growth in Zr-2.5% Nb pressure tube

    Science.gov (United States)

    Krause, T. W.; Martin, A. E.; Sheppard, R. R.; Schankula, J. J.

    2000-05-01

    Zr-2.5% wt. Nb pressure tubes (PTs) form the core of the heat transport system in CANDU nuclear reactors. These 6 m long, 100 mm diameter tubes are operated at elevated temperatures (nominally 300 °C) and at pressures that produce hoop stresses that are 25% of the ultimate tensile strength of the PT (120 Mpa). Therefore, detection and characterization of flaws in these components becomes crucial for their continued pressure retaining integrity. If a flaw is detected, however, the cost of PT replacement is expensive. Periodic in-service inspection of a flaw that demonstrates no change in flaw characteristics can be used to allow a pressure tube to remain in-service. This requires confidence in the accuracy and reliability of methods used to inter flaw characteristics. Such confidence can only be developed by comparing nondestructive predictions with results from destructive examinations. In this work, eddy current testing was used to monitor the progressive stages of a fatigue crack, grown through pressure cycling from a notch on the inner surface of a PT. Results from a differential lift-off compensated eddy current probe were used to produce sizing estimates of the crack grown between 35% (base of notch) and 74% of the PT wall. A comparison with a destructive examination of the crack demonstrated sensitivity too changes in crack depth accurate to 5% of the tube wall thickness. Such results, combined with similar information obtained from ultrasonics will increase confidence in interpretation of PT inspection data.

  17. Flow mixing inside a control-rod guide tube - Experimental tests and CFD simulations

    Energy Technology Data Exchange (ETDEWEB)

    Angele, Kristian, E-mail: Kristian.Angele@vattenfall.com [Vattenfall Research and Development AB, SE-81426 Aelvkarleby (Sweden); Odemark, Ylva; Cehlin, Mathias; Hemstroem, Bengt; Hoegstroem, Carl-Maikel; Henriksson, Mats [Vattenfall Research and Development AB, SE-81426 Aelvkarleby (Sweden); Tinoco, Hernan; Lindqvist, Hans [Forsmarks Kraftgrupp AB, SE-74203 Oesthammar (Sweden)

    2011-12-15

    This paper covers a combined experimental and computational effort carried out at Vattenfall Research and Development AB in order to study the thermal mixing in the annular region between a top tube and a control-rod stem. The low frequency thermal fluctuations in this region can result in problems with thermal fatigue and have caused cracks in the control-rod stems of several nuclear reactors (). The flow in the vertical annular region formed by the top tube and the control-rod stem is characterized by the mixing of hot bypass flow with cold crud-removal flow. The crud-removal flow is flowing upwards along the control-rod stem, and the warmer bypass flow is entering through eight horizontal holes positioned in the lower part of the guide tube and four holes in the upper part of the top tube, forming jets. Two full-scale models of a control rod, including the control-rod stem and the guide tube, were constructed. The first model, designed to work at atmospheric conditions, was made of Plexiglass, in order to be able to visualize the mixing process, whereas the second one was made of steel to allow for a higher temperature difference between the two flows, and the heating of the top tube. CFD simulations of the case at atmospheric conditions were also carried out. Both the experiments and the simulations showed that the mixing region between the cold crud-removal flow and the warm bypass flow is dominated by large flow structures coming from above. The process is characterized by low frequency, high amplitude temperature fluctuations. The process is basically hydrodynamic, caused by the downward transport of flow structures originated at the upper bypass inlets. The damping thermal effects through buoyancy is of secondary importance, as also the scaling analysis shows, however a slight damping of the temperature fluctuations can be seen due to natural convection due to a pre-heating of the cold crud-removal flow. The comparison between numerical and experimental

  18. Design of a Kaplan turbine for a wide range of operating head -Curved draft tube design and model test verification-

    Science.gov (United States)

    KO, Pohan; MATSUMOTO, Kiyoshi; OHTAKE, Norio; DING, Hua

    2016-11-01

    As for turbomachine off-design performance improvement is challenging but critical for maximising the performing area. In this paper, a curved draft tube for a medium head Kaplan type hydro turbine is introduced and discussed for its significant effect on expanding operating head range. Without adding any extra structure and working fluid for swirl destruction and damping, a carefully designed outline shape of draft tube with the selected placement of center-piers successfully supresses the growth of turbulence eddy and the transport of the swirl to the outlet. Also, more kinetic energy is recovered and the head lost is improved. Finally, the model test results are also presented. The obvious performance improvement was found in the lower net head area, where the maximum efficiency improvement was measured up to 20% without compromising the best efficiency point. Additionally, this design results in a new draft tube more compact in size and so leads to better construction and manufacturing cost performance for prototype. The draft tube geometry parameter designing process was concerning the best efficiency point together with the off-design points covering various water net heads and discharges. The hydraulic performance and flow behavior was numerically previewed and visualized by solving Reynolds-Averaged Navier-Stokes equations with Shear Stress Transport turbulence model. The simulation was under the assumption of steady-state incompressible turbulence flow inside the flow passage, and the inlet boundary condition was the carefully simulated flow pattern from the runner outlet. For confirmation, the corresponding turbine efficiency performance of the entire operating area was verified by model test.

  19. Ear Tubes

    Science.gov (United States)

    ... ENTCareers Marketplace Find an ENT Doctor Near You Ear Tubes Ear Tubes Patient Health Information News media ... and throat specialist) may be considered. What are ear tubes? Ear tubes are tiny cylinders placed through ...

  20. Thermal expansion of a fused quartz tube in a dimensional stability test facility.

    Science.gov (United States)

    Wolff, E G; Eselun, S A

    1979-04-01

    A facility to monitor the dimensional stability of structures of arbitrary size or shape under varying temperature and pressure conditions is described. Real-time linear displacements are measured with a modified Michelson laser interferometer to a resolution of less than one part in 10(7) and an accuracy of approximately 2 parts in 10(7) for approximately 1 m gauge lengths. Verification of the system accuracy with a quartz tube required considerations of its fabrication and compositional characteristics.

  1. Construction and Test of New Precision Drift-Tube Chambers for the ATLAS Muon Spectrometer

    CERN Document Server

    Kroha, Hubert

    2017-01-01

    ATLAS muon detector upgrades aim for increased acceptance for muon triggering and precision tracking and for improved rate capability of the muon chambers in the high-background regions of the detector with increasing LHC luminosity. The small-diameter Muon Drift Tube (sMDT) chambers have been developed for these purposes. With half of the drift-tube diameter of the MDT chambers and otherwise unchanged operating parameters, sMDT chambers share the advantages of the MDTs, but have an order of magnitude higher rate capability and can be installed in detector regions where MDT chambers do not fit in. The chamber assembly methods have been optimized for mass production, minimizing construction time and personnel. Sense wire positioning accuracies of 5 ?micons have been achieved in serial production for large-size chambers comprising several hundred drift tubes. The construction of new sMDT chambers for installation in the 2016/17 winter shutdown of the LHC and the design of sMDT chambers in combination with new R...

  2. Construction and test of new precision drift-tube chambers for the ATLAS muon spectrometer

    Science.gov (United States)

    Kroha, H.; Kortner, O.; Schmidt-Sommerfeld, K.; Takasugi, E.

    2017-02-01

    ATLAS muon detector upgrades aim for increased acceptance for muon triggering and precision tracking and for improved rate capability of the muon chambers in the high-background regions of the detector with increasing LHC luminosity. The small-diameter Muon Drift Tube (sMDT) chambers have been developed for these purposes. With half of the drift-tube diameter of the MDT chambers and otherwise unchanged operating parameters, sMDT chambers share the advantages of the MDTs, but have an order of magnitude higher rate capability and can be installed in detector regions where MDT chambers do not fit in. The chamber assembly methods have been optimized for mass production, minimizing construction time and personnel. Sense wire positioning accuracies of 5 μm have been achieved in serial production for large-size chambers comprising several hundred drift tubes. The construction of new sMDT chambers for installation in the 2016/17 winter shutdown of the LHC and the design of sMDT chambers in combination with new RPC trigger chambers for replacement of the inner layer of the barrel muon spectrometer are in progress.

  3. Effects of post-sampling analysis time, type of blood samples and collection tubes on values of blood gas testing.

    Science.gov (United States)

    Smajić, Jasmina; Kadić, Damira; Hasić, Sabaheta; Serdarević, Nafija

    2015-08-01

    To investigate effects of post-sampling analysis time, a type of blood samples and collection tubes on blood gas testing. This study included 100 patients at the Clinic for Pulmonary Diseases, Clinical Centre Sarajevo. The partial pressure of oxygen (pO2) and carbon dioxide (pCO2), and the oxygen saturation level of hemoglobin (sO2) were analyzed in the arterial blood samples (ABS) and capillary blood samples (CBS) by a potentiometric method using a blood gas analyzer ABL 555 (Radiometer, Copenhagen, Denmark). Paired measurements of ABS were performed within 15 minutes and after 60 minutes from sampling and compared. The results of CBS obtained within 15 minutes were compared with matching ABS results, as well as the results obtained from CBS within 15 minutes taken into glass and plastic tubes. pO2 and sO2 values were significantly lower after 60 minutes compared to those within 15 minutes in ABS (9.20±1.89 vs. 9.51±1.95 and 91.25±5.03 vs. 92.40±4.5; pblood values were not influenced significantly (p>0.05). The length of post-sampling analysis time, a type of blood samples and collection tubes have significant impact on blood oxygen parameters. Analysis within 15 minutes after blood sampling is considered as appropriate. Copyright© by the Medical Assotiation of Zenica-Doboj Canton.

  4. Design, construction and long life endurance testing of cathode assemblies for use in microwave high-power transmitting tubes

    Science.gov (United States)

    Batra, R.; Marino, D.

    1986-01-01

    The cathode life test program sponsored by NASA Lewis Research Center at Watkins-Johnson Company has been in continuous operation since 1972. Its primary objective has been to evaluate the long life capability of barium dispenser cathodes to produce emission current densities of 2 A sq. cm. or more in an operational environment simulating that of a highpower microwave tube. The life test vehicles were equipped with convergent flow electron guns, drift space tubes with solenoid magnets for electron beam confinement and water-cooled depressed collectors. A variety of cathode types has been tested, including GE Tungstate, Litton Impregnated, Philips Type B and M, Semicon types S and M, and Spectra-Mat Type M. Recent emphasis has been on monitoring the performance of Philips Type M cathodes at 2 A sq. cm. and Sprectra-Mat and Semicon Type M cathodes at 4 A sq. cm. These cathodes have been operated at a constant current of 616 mA and a cathode anode voltage on the order of 10 kV. Cathode temperatures were maintained at 1010 C true as measured from black body holes in the backs of the cathodes. This report presents results of the cathode life test program from July l982 through April l986. The results include hours of operation and performance data in the form of normalized emission current density versus temperature curves (Miram plots).

  5. Small-bore chest tubes seem to perform better than larger tubes in treatment of spontaneous pneumothorax

    DEFF Research Database (Denmark)

    Iepsen, Ulrik Winning; Ringbæk, Thomas

    2013-01-01

    The aim of this study was to compare the efficacy and complications of surgical (large-bore) chest tube drainage with smaller and less invasive chest tubes in the treatment of non-traumatic pneumothorax (PT). ......The aim of this study was to compare the efficacy and complications of surgical (large-bore) chest tube drainage with smaller and less invasive chest tubes in the treatment of non-traumatic pneumothorax (PT). ...

  6. Accuracy Combination Test of Classical and Modern Technical Analysis: A Case Study in Stock of PT Wijaya Karya Tbk

    OpenAIRE

    Agustini Hamid

    2016-01-01

    The research aimed to measure the accuracy and combination of Classic and Modern Technical Analysis. PT Wijaya Karya Tbk (WIKA)’s stock in two periods is the sample of research. Technical analysis was used to predict stock prices by observing changes in historical share price. Practically, technical analysis is divided into Classic Technical and Modern. Research was conducted by library study and using a computer software. Microsft Excel was used for the simulation and Chart Nexus for analyzi...

  7. Measuring equipment for controlling the anode current during training and testing of the X-ray tubes

    Science.gov (United States)

    Perez Vasquez, N. O.; Kostrin, D. K.; Uhov, A. A.

    2017-02-01

    In this paper the features of controlling of the anode current of the X-ray tubes during their training and testing are described. Requirements for developing of the control and measuring equipment are given. In detail are shown the approaches to the development of two types of microammeters with optical signal transmission: analog, with compensation of the nonlinearity of the transfer characteristics with the use of the optical negative feedback, and digital, in which the values of anodic current are transfered using a microcontroller.

  8. Indoor test for thermal performance of the Sunmaster evacuated tube (liquid) solar collector

    Science.gov (United States)

    1979-01-01

    The test procedures used to obtain the thermal performance data for a solar collector under simulated conditions are presented. Tests included a stagnation test, a time constant test, a thermal efficiency test, an incident angle modifier test, and a hot fill test. All tests were performed at ambient conditions and the transient effect and the incident angle effect on the collector were determined. The solar collector is a water working fluid type.

  9. Performance test results of mock-up model test facility with a full-scale reaction tube for HTTR hydrogen production system. Contract research

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Yoshiyuki; Hayashi, Koji; Kato, Michio [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment] [and others

    2003-03-01

    Research on a hydrogen production system by steam reforming of methane, chemical reaction; CH{sub 4} + H{sub 2}O {yields} 3H{sub 2}O + CO, has been carried out to couple with the HTTR for establishment of high-temperature nuclear heat utilization technology and contribution to hydrogen energy society in future. The mock-up test facility with a full-scale reaction tube test facility, a model simulating one reaction tube of a steam reformer of the HTTR hydrogen production system in full scale, was fabricated to perform tests on controllability, hydrogen production performance etc. under the same pressure and temperature conditions as those of the HTTR hydrogen production system. The design and fabrication of the test facility started from 1997, and the all components were installed until September in 2001. In a performance test conducted from October in 2001 to February in 2002, performance of each component was examined and hydrogen of 120m{sup 3}{sub N}/h was successfully produced with high-temperature helium gas. This report describes the performance test results on components performance, hydrogen production characteristics etc., and main troubles and countermeasures. (author)

  10. Screening for High-Temperature Tolerant Cotton Cultivars by Testing In Vitro Pollen Germination, Pollen Tube Growth and Boll Retention

    Institute of Scientific and Technical Information of China (English)

    Zhi Liu; You-Lu Yuan; Shao-Qing Liu; Xiao-Nan Yu; Li-Qun Rao

    2006-01-01

    With radical global climate change and global warming, high temperature stress has become one of major factors exerting a major influence on crop production. In the cotton (Gossypium hirsutum L.)-growing areas of China, especially in the Yangtze River valley, unexpected periodic episodes of extreme heat stress usually occur in July and August, the peak time of cotton flowering and boll loading, resulting in lower boll set and lint yield. Breeding programs for screening high temperature-tolerant cotton germplasm and cultivars are urgent in order to stabilize yield in the current and future warmer weather conditions. In the present study, 14 cotton cultivars were quantified for in vitro pollen germination and pollen tube growth in response to temperatures ranging from 10 to 50 ℃ at 5 ℃ intervals. Different cotton genotypes varied in their in vitro pollen germination and pollen tube length responses to the different temperatures. Maximum pollen germination and pollen tube length ranged from 25.2% to 56.2% and from 414 to 682 μm, respectively.The average cardinal temperatures (Tmin, Topt, and Tmax) also varied among the 14 cultivars and were 11.8,27.3, and 42.7 ℃ for pollen germination and 11.8, 27.8, and 44.1 ℃ for maximum pollen tube length. Variations in boll retention and boll numbers per plant in field experiments were found for the 14 cotton cultivars and the boll retention and boll retained per plant on 20 August varied considerably in different years according to weather conditions. Boll retention on 20 August was highly correlated with maximum pollen germination (R2=0.84) and pollen tube length (R2=0.64). A screening method based on principle component analysis of the combination of pollen characteristics in an in vitro experiment and boll retention testing in the field environment was used in the present study and, as a result, the 14 cotton cultivars could be classified as tolerant, moderately tolerant, moderately susceptible and susceptible to high

  11. Eddy Current Flaw Testing Probe with High Performance in Detecting Flaws during In-Service Inspection of Tubing

    Science.gov (United States)

    Koyama, Kiyoshi; Hoshikawa, Hiroshi

    Eddy current flaw testing that uses changes in the impedance of the test coil as the electromagnetic field interacts with the test material is a non-destructive testing method. It can be used to inspect test material at high speed without bringing the test coil into contact with the test material. Therefore, it is widely used for product inspection. In the inspection of heat exchanger tubing in power plants and chemical plants, eddy current flaw testing is performed by using an inner probe, because of the structural restrictions of such plants. However, high levels of wobble noise and support plate noise occur in the conventional method using a rotating pancake coil. The authors therefore propose new minimal-noise eddy current inner probes. Two new types of probes have been developed: one for detecting axial flaws, and the other for detecting circumference flaws. These probes can detect flaws with a low level of noise. The phase of the flaw signal by the new probes changes according to the flaw depth. As a result, the signal phase by the new probes can be used for evaluating the depth of surface flaws.

  12. Ultrasonic testing of canning tubes in stainless steel of the EL 4 reactor; Controle par ultrasons des tubes de gaine en acier inoxydable du reacteur EL 4

    Energy Technology Data Exchange (ETDEWEB)

    Prot, A.; Monnier, P. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    From all the methods possible for controlling thin cans the one chosen, for numerous reasons, vas that making use of ultrasonic techniques. A method has been developed which should make it possible to carry out a rapid and efficient industrial control of canning tubes, The reasons for the choice of the ultrasonic method are given in detail, together with the principles of the method and the actual control parameters. In the present state of our research, it should be possible to control at least 50 000 tubes a year. Improvements brought about in the details of the control technique itself should make it possible to increase this rate considerably. (authors) [French] Parmi toutes les methodes possibles de controle des gaines minces, le procede retenu pour de multiples raisons a ete celui faisant appel a la technique des ultrasons. Une methode a ete mise au point qui doit permettre un controle industriel rapide et efficace des tubes de gaine. Sont exposes en detail, les raisons du choix de la methode par ultrasons, les principes de cette methode et les parametres du controle proprement dit. Dans l'etat actuel de nos etudes la cadence devrait permettre le controle de 50000 tubes par an au minimum. Des ameliorations de detail portant sur la technique de controle elle-meme, doivent permettre d'accelerer tres notablement cette cadence. (auteurs)

  13. Generation of dried tube specimen for HIV-1 viral load proficiency test panels: a cost-effective alternative for external quality assessment programs.

    Science.gov (United States)

    Ramos, Artur; Nguyen, Shon; Garcia, Albert; Subbarao, Shambavi; Nkengasong, John N; Ellenberger, Dennis

    2013-03-01

    Participation in external quality assessment programs is critical to ensure quality clinical laboratory testing. Commercially available proficiency test panels for HIV-1 virus load testing that are used commonly in external quality assessment programs remain a financial obstacle to resource-limited countries. Maintaining cold-chain transportation largely contributes to the cost of traditional liquid proficiency test panels. Therefore, we developed and evaluated a proficiency test panel using dried tube specimens that can be shipped and stored at ambient temperature. This dried tube specimens panel consisted of 20 μl aliquots of a HIV-1 stock that were added to 2 ml tubes and left uncapped for drying, as a preservation method. The stability of dried tube specimens at concentrations ranging from 10² to 10⁶·⁵ RNA copies/ml was tested at different temperatures over time, showing no viral load reduction at 37 °C and a decrease in viral load smaller than 0.5 Log₁₀ at 45 °C for up to eight weeks when compared to initial results. Eight cycles of freezing-thawing had no effect on the stability of the dried tube specimens. Comparable viral load results were observed when dried tube specimen panels were tested on Roche CAPTAQ, Abbott m2000, and Biomerieux easyMAG viral load systems. Preliminary test results of dried proficiency test panels shipped to four African countries at ambient temperature demonstrated a low inter assay variation (SD range: 0.29-0.41 Log₁₀ RNA copies/ml). These results indicated that HIV-1 proficiency test panels generated by this methodology might be an acceptable alternative for laboratories in resource-limited countries to participate in external quality assessment programs.

  14. Construction and Test of Muon Drift Tube Chambers for High Counting Rates

    CERN Document Server

    Schwegler, Philipp; Dubbert, Jörg

    2010-01-01

    Since the start of operation of the Large Hadron Collider (LHC) at CERN on 20 November 2009, the instantaneous luminosity is steadily increasing. The muon spectrometer of the ATLAS detector at the LHC is instrumented with trigger and precision tracking chambers in a toroidal magnetic field. Monitored Drift-Tube (MDT) chambers are employed as precision tracking chambers, complemented by Cathode Strip Chambers (CSC) in the very forward region where the background counting rate due to neutrons and γ's produced in shielding material and detector components is too high for the MDT chambers. After several upgrades of the CERN accelerator system over the coming decade, the instantaneous luminosity is expected to be raised to about five times the LHC design luminosity. This necessitates replacement of the muon chambers in the regions with the highest background radiation rates in the so-called Small Wheels, which constitute the innermost layers of the muon spectrometer end-caps, by new detectors with higher rate cap...

  15. Design and microwave test of an ultrawideband input/output structure for sheet beam travelling wave tubes.

    Science.gov (United States)

    Shu, Guoxiang; Wang, Jianxun; Liu, Guo; Yang, Liya; Luo, Yong; Wang, Shafei

    2015-06-01

    Broadband operation is of great importance for the applications of travelling wave tubes such as high-data communication and wideband radar. An input/output (I/O) structure operating with broadband property plays a significant role to achieve these applications. In this paper, a Y-type branch waveguide (YTBW) coupler and its improvements are proposed and utilized to construct an extremely wideband I/O structure to ensure the broadband operation for sheet beam travelling wave tubes (SB-TWTs). Cascaded reflection resonators are utilized to improve the isolation characteristic and transmission efficiency. Furthermore, to minimize the reflectivity of the port connected with the RF circuit, wave-absorbing material (WAM) is loaded in the resonator. Simulation results for the YTBW loaded with WAM predict an excellent performance with a 50.2% relative bandwidth for port reflectivity under -15 dB, transmission up to -1.5 dB, and meanwhile isolation under -20 dB. In addition, the coupler has a relatively compact configuration and the beam tunnel can be widened, which is beneficial for the propagation of the electrons. A Q-band YTBW loaded with two reflection resonators is fabricated and microwave tested. Vector network analyzer (VNA) measured results have an excellent agreement with our simulation, which verify our theoretical analysis and simulation calculation.

  16. Influence of material and testing parameters on the lifetime of TBC systems with MCrAlY and NiPtAl bondcoats

    Energy Technology Data Exchange (ETDEWEB)

    Song, Peng

    2012-08-31

    The oxidation behavior of the bond coat is an important factor determining the lifetime of thermal barrier coatings (TBC) in the advanced gas turbine components. In the present work, the effect of various testing parameters, such as hot/cold dwell time, heating/cooling rate, atmosphere composition on the bondcoat oxidation and associated TBC lifetime has been investigated. The range of coating systems included Electron Beam - Physical Vapor Deposited (EB-PVD) and Air Plasma Sprayed (APS) TBC's with MCrAlY (M = Ni, Co) and NiPtAl-bondcoats of various compositions. The effect of the testing parameters strongly depended on the type and properties of the studied system. The lifetime of EB-PVD TBC systems with conventional MCrAlY and NiPtAl bondcoats forming uniform, flat alumina scales was found to be limited by critical scale thickness, upon which a rapid crack propagation at the scale/bondcoat interface results in macroscopic failure. The lifetime of such systems was found to be affected by factors, which influence the scale growth rate and adherence (in particular by oxygen partial pressure (pO{sub 2}) and water vapor content in the test gas in the case of MCrAlY), whereas the temperature cyclic frequency showed no significant effect. NiPtAl bondcoats showed a superior behavior than the conventional MCrAlY-bondcoats due to slower scale growth rate and better scale adherence. For EB-PVD TBC systems with Zr-doped MCrAlYbondcoats the lifetime is mainly determined by the crack growth rate in the inhomogeneous inwardly growing oxide scales, whereas the lifetime is not dependent on the pO{sub 2} but rather on the cyclic frequency. For APS TBC systems the bondcoat oxidation is only one of several factors determining the ceramic topcoat lifetime. Therefore the oxide scale adherence is of less importance for lifetime of APS TBCs as compared to EBPVD TBCs. For the former systems, the cracks initiated at the convex asperities of the rough oxide scale / bondcoat interface

  17. Direct Determination of the Ionization Energies of PtC, PtO, and PtO2 with VUVRadiation

    Energy Technology Data Exchange (ETDEWEB)

    Citir, Murat; Metz, Ricardo B.; Belau, Leonid; Ahmed, Musahid

    2008-07-21

    Photoionization efficiency curves were measured for gas-phase PtC, PtO, and PtO2 using tunable vacuum ultraviolet (VUV) radiation at the Advanced Light Source. The molecules were prepared by laser ablation of a platinum tube, followed by reaction with CH4 or N2O and supersonic expansion. These measurements providethe first directly measured ionization energy for PtC, IE(PtC) = 9.45 +- 0.05 eV. The direct measurement also gives greatly improved ionization energies for the platinum oxides, IE(PtO) = 10.0 +- 0.1 eV and IE(PtO2) = 11.35 +- 0.05 eV. The ionization energy connects the dissociation energies of the neutral and cation, leading to greatly improved 0 K bond dissociation energies for the neutrals: D0(Pt-C) = 5.95 +- 0.07 eV, D0(Pt-O)= 4.30 +- 0.12 eV, and D0(OPt-O) = 4.41 +- 0.13 eV, as well as enthalpies of formation for the gas-phase molecules Delta H0 f,0(PtC(g)) = 701 +- 7 kJ/mol, Delta H0f,0(PtO(g)) = 396 +- 12 kJ/mol, and Delta H0f,0(PtO2(g)) = 218 +- 11 kJ/mol. Much of the error in previous Knudsen cell measurements of platinum oxide bond dissociation energies is due to the use of thermodynamic second law extrapolations. Third law values calculated using statistical mechanical thermodynamic functions are in much better agreement with values obtained from ionization energies and ion energetics. These experiments demonstrate that laser ablation production with direct VUV ionization measurements is a versatile tool to measure ionization energies and bond dissociation energies for catalytically interesting species such as metal oxides and carbides.

  18. Research on Phased Array Automatically Ultrasonic Testing Technique of Tube to Tube-sheet Welds in Heat Exchanger%换热器管板角焊缝相控阵自动超声检测技术研究

    Institute of Scientific and Technical Information of China (English)

    郭伟灿; 钱盛杰; 凌张伟

    2015-01-01

    在换热器的制作过程中,换热管与管板常采用焊接形式,焊缝的质量是保证换热器长期正常运行的关键。常规的超声检测方法具有系统复杂、检测效率低等缺点。因此,提出了相控阵超声检测技术,并开发了相控阵超声检测系统,以实现对管板角焊缝的自动超声检测。系统由周向步进电机实现周向扫查,纵向扫查采用相控阵探头电子线扫查,从而实现超声 C 扫描检测。通过带有气孔、未熔合等典型缺陷对检测系统进行试验研究。结果表明,该技术可以有效地检测出换热器管板角焊缝中的典型缺陷。%In the process of produce heat exchangers,heat exchanger′s tube and tube sheet conjunction adopt the form of welding,the quality of welding is the key insurance for the long and normal operation of the heat exchangers.The conventional ultrasonic testing method has many disadvantages like complicated system and low efficiency of detection.Thus,it puts forward the phased array ultrasonic testing technique and develops the ultrasonic testing system to accomplish the automatically ultrasonic testing of the tube to tube-sheet welds.The ultrasonic C-scan was carried out by the ultrasonic testing system with its circumfer-ential scanning by a mechanical scanning device while the axial electronic linear scanning by the phased array probe.At last,the tests on samples with typical flaws such as porosity flaws and the incomplete fu-sion flaws were performed by the ultrasonic testing system.Experiment results showed that the phased ar-ray ultrasonic technique could effectively detect the typical flaws in the tube to tube-sheet welds of heat exchanger.

  19. PT AND PT/NI "NEEDLE" ELETROCATALYSTS ON CARBON NANOTUBES WITH HIGH ACTIVITY FOR THE ORR

    Energy Technology Data Exchange (ETDEWEB)

    Colon-Mercado, H.

    2011-11-10

    Platinum and platinum/nickel alloy electrocatalysts supported on graphitized (gCNT) or nitrogen doped carbon nanotubes (nCNT) are prepared and characterized. Pt deposition onto carbon nanotubes results in Pt 'needle' formations that are 3.5 nm in diameter and {approx}100 nm in length. Subsequent Ni deposition and heat treatment results in PtNi 'needles' with an increased diameter. All Pt and Pt/Ni materials were tested as electrocatalysts for the oxygen reduction reaction (ORR). The Pt and Pt/Ni catalysts showed excellent performance for the ORR, with the heat treated PtNi/gCNT (1.06 mA/cm{sup 2}) and PtNi/nCNT (0.664 mA/cm{sup 2}) showing the highest activity.

  20. Development and Execution of a Large-scale DDT Tube Test for IHE Material Qualification

    Energy Technology Data Exchange (ETDEWEB)

    Parker, Gary Robert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Broilo, Robert M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lopez-Pulliam, Ian Daniel [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Vaughan, Larry Dean [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-10-24

    Insensitive High Explosive (IHE) Materials are defined in Chapter IX of the DOE Explosive Safety Standard (DOE-STD-1212-2012) as being materials that are massdetonable explosives that are so insensitive that the probability of accidental initiation or transition from burning to detonation is negligible1. There are currently a number of tests included in the standard that are required to qualify a material as IHE, however, none of the tests directly evaluate for the transition from burning to detonation (aka deflagration-to-detonation transition, DDT). Currently, there is a DOE complex-wide effort to revisit the IHE definition in DOE-STD-1212-2012 and change the qualification requirements. The proposal lays out a new approach, requiring fewer, but more appropriate tests, for IHE Material qualification. One of these new tests is the Deflagration-to-Detonation Test. According to the redefinition proposal, the purpose of the new deflagration-todetonation test is “to demonstrate that an IHE material will not undergo deflagration-to-detonation under stockpile relevant conditions of scale, confinement, and material condition. Inherent in this test design is the assumption that ignition does occur, with onset of deflagration. The test design will incorporate large margins and replicates to account for the stochastic nature of DDT events.” In short, the philosophy behind this approach is that if a material fails to undergo DDT in a significant over-test, then it is extremely unlikely to do so in realistic conditions. This effort will be valuable for the B61 LEP to satisfy their need qualify the new production lots of PBX 9502. The work described in this report is intended as a preliminary investigation to support the proposed design of an overly conservative, easily fielded DDT test for updated IHE Material Qualification standard. Specifically, we evaluated the aspects of confinement, geometry, material morphology and temperature. We also developed and tested a

  1. The Development of Expansion Plug Wedge Test for Clad Tubing Structure Mechanical Property Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jy-An John [ORNL; Jiang, Hao [ORNL

    2016-01-12

    To determine the tensile properties of irradiated fuel cladding in a hot cell, a simple test was developed at the Oak Ridge National Laboratory (ORNL) and is described fully in US Patent Application 20060070455, “Expanded plug method for developing circumferential mechanical properties of tubular materials.” This method is designed for testing fuel rod cladding ductility in a hot cell using an expandable plug to stretch a small ring of irradiated cladding material. The specimen strain is determined using the measured diametrical expansion of the ring. This method removes many complexities associated with specimen preparation and testing. The advantages are the simplicity of measuring the test component assembly in the hot cell and the direct measurement of the specimen’s strain. It was also found that cladding strength could be determined from the test results.

  2. Coincident steam generator tube rupture and stuck-open safety relief valve carryover tests: MB-2 steam generator transient response test program

    Energy Technology Data Exchange (ETDEWEB)

    Garbett, K; Mendler, O J; Gardner, G C; Garnsey, R; Young, M Y

    1987-03-01

    In PWR steam generator tube rupture (SGTR) faults, a direct pathway for the release of radioactive fission products can exist if there is a coincident stuck-open safety relief valve (SORV) or if the safety relief valve is cycled. In addition to the release of fission products from the bulk steam generator water by moisture carryover, there exists the possibility that some primary coolant may be released without having first mixed with the bulk water - a process called primary coolant bypassing. The MB-2 Phase II test program was designed specifically to identify the processes for droplet carryover during SGTR faults and to provide data of sufficient accuracy for use in developing physical models and computer codes to describe activity release. The test program consisted of sixteen separate tests designed to cover a range of steady-state and transient fault conditions. These included a full SGTR/SORV transient simulation, two SGTR overfill tests, ten steady-state SGTR tests at water levels ranging from very low levels in the bundle up to those when the dryer was flooded, and three moisture carryover tests without SGTR. In these tests the influence of break location and the effect of bypassing the dryer were also studied. In a final test the behavior with respect to aerosol particles in a dry steam generator, appropriate to a severe accident fault, was investigated.

  3. Engineering the Activity and Stability of Pt-Alloy Cathode Fuel-Cell Electrocatalysts by Tuning the Pt-Pt Distance

    DEFF Research Database (Denmark)

    Escribano, Maria Escudero; Malacrida, Paolo; Vej-Hansen, Ulrik Grønbjerg

    2014-01-01

    based on alloys of Pt and lanthanides. Sputter-cleaned, polycrystalline Pt5Gd shows a five-fold increase in ORR activity [3], relative to Pt at 0.9 V in 0.1 M HClO4. The rest of the Pt5Ln (Ln = lanthanide) tested present at least a 3-fold enhancement in activity [4,5]. In all cases, a Pt overlayer...

  4. Reliable experimental setup to test the pressure modulation of Baerveldt Implant tubes for reducing post-operative hypotony

    Science.gov (United States)

    Ramani, Ajay

    Glaucoma encompasses a group of conditions that result in damage to the optic nerve and can cause loss of vision and blindness. The nerve is damaged due to an increase in the eye's internal (intraocular) pressure (IOP) above the nominal range of 15 -- 20 mm Hg. There are many treatments available for this group of diseases depending on the complexity and stage of nerve degradation. In extreme cases where drugs or laser surgery do not create better conditions for the patient, ophthalmologists use glaucoma drainage devices to help alleviate the IOP. Many drainage implants have been developed over the years and are in use; but two popular implants are the Baerveldt Glaucoma Implant and the Ahmed Glaucoma Valve Implant. Baerveldt Implants are non-valved and provide low initial resistance to outflow of fluid, resulting in post-operative complications such as hypotony, where the IOP drops below 5 mm of Hg. Ahmed Glaucoma Valve Implants are valved implants which initially restrict the amount of fluid flowing out of the eye. The long term success rates of Baerveldt Implants surpass those of Ahmed Valve Implants because of post-surgical issues; but Baerveldt Implants' initial effectiveness is poor without proper flow restriction. This drives the need to develop new ways to improve the initial effectiveness of Baerveldt Implants. A possible solution proposed by our research team is to place an insert in the Baerveldt Implant tube of inner diameter 305 microns. The insert must be designed to provide flow resistance for the early time frame [e.g., first 30 -- 60 post-operative days] until sufficient scar tissue has formed on the implant. After that initial stage with the insert, the scar tissue will provide the necessary flow resistance to maintain the IOP above 5 mm Hg. The main objective of this project was to develop and validate an experimental apparatus to measure pressure drop across a Baerveldt Implant tube, with and without inserts. This setup will be used in the

  5. High pressure CO hydrogenation over bimetallic Pt-Co catalysts

    DEFF Research Database (Denmark)

    Christensen, Jakob Munkholt; Medford, Andrew James; Studt, Felix

    2014-01-01

    The potential of bimetallic Pt-Co catalysts for production of higher alcohols in high pressure CO hydrogenation has been assessed. Two catalysts (Pt3Co/SiO2 and PtCo/SiO2) were tested, and the existing literature on CO hydrogenation over Pt-Co catalysts was reviewed. It is found that the catalyst...

  6. Amorphous Pt@PdCu/CNT Catalyst for Methanol Electrooxidation ...

    African Journals Online (AJOL)

    A multi-walled carbon nanotube-supported, Pt decorated nano-sized ... alloy cores (denoted as Pt@PdCu/CNT) catalyst with lower Pt loading is synthesized via a ... The electrochemical activity of the Pt@PdCu/CNT catalyst is tested by cyclic ...

  7. Clinical factors associated with a Candida albicans Germ Tube Antibody positive test in Intensive Care Unit patients

    Directory of Open Access Journals (Sweden)

    Martín-Mazuelos Estrella

    2011-03-01

    Full Text Available Abstract Background Poor outcomes of invasive candidiasis (IC are associated with the difficulty in establishing the microbiological diagnosis at an early stage. New scores and laboratory tests have been developed in order to make an early therapeutic intervention in an attempt to reduce the high mortality associated with invasive fungal infections. Candida albicans IFA IgG has been recently commercialized for germ tube antibody detection (CAGTA. This test provides a rapid and simple diagnosis of IC (84.4% sensitivity and 94.7% specificity. The aim of this study is to identify the patients who could be benefited by the use of CAGTA test in critical care setting. Methods A prospective, cohort, observational multicentre study was carried out in six medical/surgical Intensive care units (ICU of tertiary-care Spanish hospitals. Candida albicans Germ Tube Antibody test was performed twice a week if predetermined risk factors were present, and serologically demonstrated candidiasis was considered if the testing serum dilution was ≥ 1:160 in at least one sample and no other microbiological evidence of invasive candidiasis was found. Results Fifty-three critically ill non-neutropenic patients (37.7% post surgery were included. Twenty-two patients (41.5% had CAGTA-positive results, none of them with positive blood culture for Candida. Neither corrected colonization index nor antifungal treatment had influence on CAGTA results. This finding could corroborate that the CAGTA may be an important biomarker to distinguish between colonization and infection in these patients. The presence of acute renal failure at the beginning of the study was more frequent in CAGTA-negative patients. Previous surgery was statistically more frequent in CAGTA-positive patients. Conclusions This study identified previous surgery as the principal clinical factor associated with CAGTA-positive results and emphasises the utility of this promising technique, which was not

  8. Serial testing for latent tuberculosis using QuantiFERON-TB Gold In-Tube: A Markov model

    Science.gov (United States)

    Moses, Mark W.; Zwerling, Alice; Cattamanchi, Adithya; Denkinger, Claudia M.; Banaei, Niaz; Kik, Sandra V.; Metcalfe, John; Pai, Madhukar; Dowdy, David

    2016-01-01

    Healthcare workers (HCWs) in low-incidence settings are often serially tested for latent TB infection (LTBI) with the QuantiFERON-TB Gold In-Tube (QFT) assay, which exhibits frequent conversions and reversions. The clinical impact of such variability on serial testing remains unknown. We used a microsimulation Markov model that accounts for major sources of variability to project diagnostic outcomes in a simulated North American HCW cohort. Serial testing using a single QFT with the recommended conversion cutoff (IFN-g > 0.35 IU/mL) resulted in 24.6% (95% uncertainty range, UR: 23.8–25.5) of the entire population testing false-positive over ten years. Raising the cutoff to >1.0 IU/mL or confirming initial positive results with a (presumed independent) second test reduced this false-positive percentage to 2.3% (95%UR: 2.0–2.6%) or 4.1% (95%UR: 3.7–4.5%), but also reduced the proportion of true incident infections detected within the first year of infection from 76.5% (95%UR: 66.3–84.6%) to 54.8% (95%UR: 44.6–64.5%) or 61.5% (95%UR: 51.6–70.9%), respectively. Serial QFT testing of HCWs in North America may result in tremendous over-diagnosis and over-treatment of LTBI, with nearly thirty false-positives for every true infection diagnosed. Using higher cutoffs for conversion or confirmatory tests (for initial positives) can mitigate these effects, but will also diagnose fewer true infections. PMID:27469388

  9. Development of Cone Wedge Ring Expansion Test to Evaluate Mechanical Properties of Clad Tubing Structure

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jy-An John [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-10-01

    To determine the hoop tensile properties of irradiated fuel cladding in a hot cell, a cone wedge ring expansion test method was developed. A four-piece wedge insert was designed with tapered angles matched to the cone shape of a loading piston. The ring specimen was expanded in the radial direction by the lateral expansion of the wedges under the downward movement of the piston. The advantages of the proposed method are that implementation of the test setup in a hot cell is simple and easy, and that it enables a direct strain measurement of the test specimen from the piston’s vertical displacement soon after the wedge-clad contact resistance is initiated.

  10. Construction and test of the final CMS barrel drift tube muon chamber prototype

    CERN Document Server

    Aguilar-Benítez, M; Arneodo, M; Banicz, K; Benettoni, M; Benvenuti, Alberto C; Bethke, Siegfried; Cerrada, M; Cirio, R; Colino, N; Conti, E; Dallavalle, G M; Daniel, M; Dattola, D; Daudo, F; De Giorgi, M; Dosselli, U; Fanfani, A; Fanin, C; Fouz-Iglesias, M C; Gasparini, F; Gasparini, U; Glacomelli, P; Giordano, V; Gonella, F; Grandi, C; Guaita, P; Guerzoni, M; Lacaprara, S; Lippi, I; Marcellini, S; Marin, J; Martinelli, R; Maselli, S; Meneguzzo, Anna Teresa; Migliore, E; Mocholí-Mocholí, J; Monaco, V; Montanari, A; Montnari, C; Odorici, F; Oller, J C; Paoletti, S; Passaseo, M; Pegoraro, M; Peroni, C; Puerta, J; Reithler, H; Romero, A; Romero, L; Ronchese, P; Rossi, A M; Rovelli, T; Sacchi, R; Salicio, J M; Staiano, A; Steinbeck, T M; Torassa, E; Travaglini, R; Ventura, L; Ventura, Sandro; Vitelli, A; Voetee, F; Wegner, M; Willmott, C; Zotto, P L; Zumerle, G

    2002-01-01

    A prototype of the CMS Barrel Muon Detector incorporating all the features of the final chambers was built using the mass production assembly procedures and tools. The performance of this prototype was studied in a muon test beam at CERN and the results obtained are presented in this paper. (12 refs).

  11. Construction and test of the final CMS Barrel Drift Tube Muon Chamber prototype

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar-Benitez, M.; Alberdi, J.; Arneodo, M.; Banicz, K.; Benettoni, M.; Benvenuti, A.; Bethke, S.; Cerrada, M. E-mail: cerrada@ciemat.es; Cirio, R.; Colino, N.; Conti, E.; Dallavalle, M.; Daniel, M.; Dattola, D.; Daudo, F.; De Giorgi, M.; Dosselli, U.; Fanfani, A.; Fanin, C.; Fouz, M.C.; Gasparini, F.; Gasparini, U.; Giacomelli, P.; Giordano, V.; Gonella, F.; Grandi, C.; Guaita, P.; Guerzoni, M.; Lacaprara, S.; Lippi, I.; Marcellini, S.; Marin, J.; Martinelli, R.; Maselli, S.; Meneguzzo, A.; Migliore, E.; Mocholi, J.; Monaco, V.; Montanari, A.; Montanari, C.; Odorici, F.; Oller, J.C.; Paoletti, S.; Passaseo, M.; Pegoraro, M.; Peroni, C.; Puerta, J.; Reithler, H.; Romero, A.; Romero, L.; Ronchese, P.; Rossi, A.M.; Rovelli, T.; Sacchi, R.; Salicio, J.M.; Staiano, A.; Steinbeck, T.; Torassa, E.; Travaglini, R.; Ventura, L.; Ventura, S.; Vitelli, A.; Voetee, F.; Wegner, M.; Willmott, C.; Zotto, P.; Zumerle, G

    2002-03-21

    A prototype of the CMS Barrel Muon Detector incorporating all the features of the final chambers was built using the mass production assembly procedures and tools. The performance of this prototype was studied in a muon test beam at CERN and the results obtained are presented in this paper.

  12. Construction and test of the final CMS Barrel Drift Tube Muon Chamber prototype

    Science.gov (United States)

    Aguilar-Benítez, M.; Alberdi, J.; Arneodo, M.; Banicz, K.; Benettoni, M.; Benvenuti, A.; Bethke, S.; Cerrada, M.; Cirio, R.; Colino, N.; Conti, E.; Dallavalle, M.; Daniel, M.; Dattola, D.; Daudo, F.; De Giorgi, M.; Dosselli, U.; Fanfani, A.; Fanin, C.; Fouz, M. C.; Gasparini, F.; Gasparini, U.; Giacomelli, P.; Giordano, V.; Gonella, F.; Grandi, C.; Guaita, P.; Guerzoni, M.; Lacaprara, S.; Lippi, I.; Marcellini, S.; Marín, J.; Martinelli, R.; Maselli, S.; Meneguzzo, A.; Migliore, E.; Mocholí, J.; Monaco, V.; Montanari, A.; Montanari, C.; Odorici, F.; Oller, J. C.; Paoletti, S.; Passaseo, M.; Pegoraro, M.; Peroni, C.; Puerta, J.; Reithler, H.; Romero, A.; Romero, L.; Ronchese, P.; Rossi, A. M.; Rovelli, T.; Sacchi, R.; Salicio, J. M.; Staiano, A.; Steinbeck, T.; Torassa, E.; Travaglini, R.; Ventura, L.; Ventura, S.; Vitelli, A.; Voetee, F.; Wegner, M.; Willmott, C.; Zotto, P.; Zumerle, G.

    2002-03-01

    A prototype of the CMS Barrel Muon Detector incorporating all the features of the final chambers was built using the mass production assembly procedures and tools. The performance of this prototype was studied in a muon test beam at CERN and the results obtained are presented in this paper.

  13. Accuracy Combination Test of Classical and Modern Technical Analysis: A Case Study in Stock of PT Wijaya Karya Tbk

    Directory of Open Access Journals (Sweden)

    Agustini Hamid

    2016-05-01

    Full Text Available The research aimed to measure the accuracy and combination of Classic and Modern Technical Analysis. PT Wijaya Karya Tbk (WIKA’s stock in two periods is the sample of research. Technical analysis was used to predict stock prices by observing changes in historical share price. Practically, technical analysis is divided into Classic Technical and Modern. Research was conducted by library study and using a computer software. Microsft Excel was used for the simulation and Chart Nexus for analyzing Modern Technical Analysis. The research period started in January 1, 2013 until December 31, 2013 and January 1, 2014 until December 31, 2014. The Classic Technical Analysis used Support, Resistance, Trendline, and Flag Patern. Meanwhile for Modern Technical Analysis used Moving Average, Stochastic, Moving Average Convergence Divergence (MACD indicator. The Classical Technical Analysis gave less result than Modern Technical Analysis. The classical give 14 investment decisions in two periods. The average return of Classical Technical is 15,50%. Meanwhile the Modern Technical Analysis gave 18 investment decisions in two periods. The average return of Modern Technical is 18,14%. Combining Classic Technical Analysis and Modern Technical Analysis gave 20 investment decisions with the average rate of return 20,41%.

  14. Assaying embryotoxicity in the test tube: current limitations of the embryonic stem cell test (EST) challenging its applicability domain.

    Science.gov (United States)

    Riebeling, Christian; Hayess, Katrin; Peters, Annelieke K; Steemans, Margino; Spielmann, Horst; Luch, Andreas; Seiler, Andrea E M

    2012-05-01

    Testing for embryotoxicity in vitro is an attractive alternative to animal experimentation. The embryonic stem cell test (EST) is such a method, and it has been formally validated by the European Centre for the Validation of Alternative Methods. A number of recent studies have underscored the potential of this method. However, the EST performed well below the 78% accuracy expected from the validation study using a new set of chemicals and pharmaceutical compounds, and also of toxicity criteria, tested to enlarge the database of the validated EST as part of the Work Package III of the ReProTect Project funded within the 6th Framework Programme of the European Union. To assess the performance and applicability domain of the EST we present a detailed review of the substances and their effects in the EST being nitrofen, ochratoxin A, D-penicillamine, methylazoxymethanol, lovastatin, papaverine, warfarin, β-aminopropionitrile, dinoseb, furosemide, doxylamine, pravastatin, and metoclopramide. By delineation of the molecular mechanisms of the substances we identify six categories of reasons for misclassifications. Some of these limitations might also affect other in vitro methods assessing embryotoxicity. Substances that fall into these categories need to be included in future validation sets and in validation guidelines for embryotoxicity testing. Most importantly, we suggest conceivable improvements and additions to the EST which will resolve most of the limitations.

  15. Assessing the Prevalence of Latent Tuberculosis among Health Care Providers in Zagazig City, Egypt Using Tuberculin Skin Test and QuantiFERON-TB Gold In-Tube Test.

    Science.gov (United States)

    El-Sokkary, Rehab H; Abu-Taleb, Ashwak M; El-Seifi, Omnia S; Zidan, Haidy E; Mortada, Eman M; El-Hossary, Dalia; Farag, Salama E

    2015-12-01

    Early detection of latent tuberculosis infection (LTBI) will prevent development of active TB among health care providers. The aim of the study was to assess the prevalence of LTBI among health care providers and compare the QuantiFERON-TB Gold In-Tube Test (QFT-GIT) and Tuberculin skin test in efforts to detect LTBI and to investigate possible associated risk factors of infection. A cross sectional study was carried out during the period of 6 months in the Chest Hospital in Zagazig city and the Nephrology Unit at Zagazig University Hospitals in 132 randomly selected health care providers who were examined for LTBI by QFT-GIT and Tuberculin skin test and for the associated risk factors as well. The prevalence of LTBI identified by QFT-GIT and by Tuberculin skin test was 28.8% and 59.1%, respectively. Poor agreement was observed between the two tests (kappa=0.10). Working more than 10 years, being nurse, diabetic and smoker were risk factors significantly associated with LTBI (p<0.05). QFT-GIT is considered a useful tool in detecting LTBI cases, especially in a country where BCG vaccination is a national policy (as in Egypt). Duration of work, profession, diabetes and smoking are the risk factors for LTBI. Active surveillance and infection control measures are recommended to reduce the risk of LTBI. Copyright© by the National Institute of Public Health, Prague 2015.

  16. Water-storage-tube systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Hemker, P.

    1981-12-24

    Passive solar collection/storage/distribution systems were surveyed, designed, fabricated, and mechanically and thermally tested. The types studied were clear and opaque fiberglass tubes, metal tubes with plastic liners, and thermosyphoning tubes. (MHR)

  17. [Tuberculosis screening program for undocumented immigrant teenagers using the QuantiFERON(®)-TB Gold In-Tube test].

    Science.gov (United States)

    Salinas, Carlos; Ballaz, Aitor; Díez, Rosa; Aguirre, Urko; Antón, Ane; Altube, Lander

    2015-07-06

    The aim of this study was to determine the prevalence of tuberculosis infection in undocumented immigrant teenagers using a tuberculin skin test (TST) for initial screening and QuantiFERON(®)-TB Gold In-Tube (QFT-GIT) as a confirmatory test. From 2007 to 2012, under 19 year-old immigrant teenagers from 2 accommodation centers of the Basque Country (Spain) were included in the study. The TST was done in all of them and the QFT-GIT was done in selected patients with a TST≥5mm. Eight hundred and forty-five immigrants were included, most of them from Africa (99.5%). Fifty-one percent of immigrants with TST ≥ 5 mm has a positive QFT-GIT. We found 2 cases of active tuberculosis (2/845: 0.24%). The concordance between TST (≥ 10 mm) and QFT-GIT was 63%, with 57% of positive concordance cases and 96% of negative concordances. There were 246 cases with TST ≥ 10 mm (29%), with significant differences between Magrebis (21.5%) and Subsaharians (67%) (Pimmigrants, we recommend implementing screening programs in this population. Using QFT-GIT, the number of candidates for chemoprophylaxis was reduced to 43% compared with TST alone (≥ 10 mm). Copyright © 2013 Elsevier España, S.L.U. All rights reserved.

  18. Performance characteristics of pulse tube refrigerators

    Science.gov (United States)

    Huang, B. J.; Tzeng, T. M.

    In the present study experiments were carried out to investigate the performance characteristics of pulse tube refrigerators. It was found that the cool-down time tc during the transient or start-up period is dominated by the time constant of the pulse tube wall τpt and that the dynamics of a basic pulse tube (BPT) refrigerator approaches that of a first-order system. For steady state operation, the cold-end temperature TL was found to vary with τpt, and the cooling load QL increases monotonically with increasing τpt. This indicates that heat pumped by the gas from the cold to the hot end increases with decreasing hpt (i.e. less energy exchange between the gas and wall). The process of heat storage or release of the pulse tube wall is thus shown to have a negative effect on the performance of a BPT refrigerator. It was thus found experimentally that the gas compression/expansion process inside the pulse tube, which is similar to a Brayton cycle but lies between isothermal and adiabatic, can explain the performance of BPT refrigerators. The present experiment also shows that the performance of a pulse tube refrigerator at transient and steady states is mainly dominated by the time constant of the pulse tube wall τpt.

  19. Study on Test-tube Flower of Tagetes patula%孔雀草试管花卉研究

    Institute of Scientific and Technical Information of China (English)

    齐迎春; 陈翔; 朱意; 袁继红; 柳俊

    2012-01-01

    为了丰富试管花卉材料,该试验建立了孔雀草实生苗到试管成花体系.孔雀草种子在MS培养基中萌发后,待长出2片真叶,继代到添加不同B9或者不同蔗糖浓度的培养基中,培养结果显示,B9对于植株高度没有明显影响,但严重抑制花芽形成.不同蔗糖浓度植株高度与花芽形成比较显示,随着蔗糖浓度的升高,植株高度显著降低,在30 g/L的培养基中,植株株高为8.5 cm,而在80 g/L培养基中只有6.1 cm.培养50d统计,蔗糖30 g/L的处理,开花率为85%,而45 g/L以上的处理开花率达100%,在80 g/L的处理中单朵花期可比对照组(蔗糖浓度30 g/L)延长11d.%In order to enrich the test -tube flower materials, the system from seedlings to test -tube flowers was established for Tagetes palula in this study. The seedlings with two euphyllas on MS medium were transferred to MS medium containing various concentrations of B9 or sucrose. The results showed that B9 exhibited little influence on the plant height, but it significantly inhibited the rate of flower bud inducement. However, the plant height was obviously decreased when the sucrose concentration in MS medium increased, and it was 8.5 cm when sucrose concentration was 30 g/L, while it was only 6. 1 cm when sucrose concentration increased to 80 g/L. After 50 days' culture in vitro, the florescence rate was 85% when the plants grew on the medium with 30 g/L sucrose, while it reached 100% when sucrose concentration was more than 45 g/L. MS medium with 80 g/L sucrose prolonged the flowering period by 10 days in comparison with that with 30 g/L sucrose.

  20. Superparamagnetic iron oxide nanoparticle attachment on array of micro test tubes and microbeakers formed on p-type silicon substrate for biosensor applications

    Science.gov (United States)

    Ghoshal, Sarmishtha; Ansar, Abul Am; Raja, Sufi O.; Jana, Arpita; Bandyopadhyay, Nil R.; Dasgupta, Anjan K.; Ray, Mallar

    2011-10-01

    A uniformly distributed array of micro test tubes and microbeakers is formed on a p-type silicon substrate with tunable cross-section and distance of separation by anodic etching of the silicon wafer in N, N-dimethylformamide and hydrofluoric acid, which essentially leads to the formation of macroporous silicon templates. A reasonable control over the dimensions of the structures could be achieved by tailoring the formation parameters, primarily the wafer resistivity. For a micro test tube, the cross-section (i.e., the pore size) as well as the distance of separation between two adjacent test tubes (i.e., inter-pore distance) is typically approximately 1 μm, whereas, for a microbeaker the pore size exceeds 1.5 μm and the inter-pore distance could be less than 100 nm. We successfully synthesized superparamagnetic iron oxide nanoparticles (SPIONs), with average particle size approximately 20 nm and attached them on the porous silicon chip surface as well as on the pore walls. Such SPION-coated arrays of micro test tubes and microbeakers are potential candidates for biosensors because of the biocompatibility of both silicon and SPIONs. As acquisition of data via microarray is an essential attribute of high throughput bio-sensing, the proposed nanostructured array may be a promising step in this direction.

  1. Superparamagnetic iron oxide nanoparticle attachment on array of micro test tubes and microbeakers formed on p-type silicon substrate for biosensor applications

    Directory of Open Access Journals (Sweden)

    Raja Sufi

    2011-01-01

    Full Text Available Abstract A uniformly distributed array of micro test tubes and microbeakers is formed on a p-type silicon substrate with tunable cross-section and distance of separation by anodic etching of the silicon wafer in N, N-dimethylformamide and hydrofluoric acid, which essentially leads to the formation of macroporous silicon templates. A reasonable control over the dimensions of the structures could be achieved by tailoring the formation parameters, primarily the wafer resistivity. For a micro test tube, the cross-section (i.e., the pore size as well as the distance of separation between two adjacent test tubes (i.e., inter-pore distance is typically approximately 1 μm, whereas, for a microbeaker the pore size exceeds 1.5 μm and the inter-pore distance could be less than 100 nm. We successfully synthesized superparamagnetic iron oxide nanoparticles (SPIONs, with average particle size approximately 20 nm and attached them on the porous silicon chip surface as well as on the pore walls. Such SPION-coated arrays of micro test tubes and microbeakers are potential candidates for biosensors because of the biocompatibility of both silicon and SPIONs. As acquisition of data via microarray is an essential attribute of high throughput bio-sensing, the proposed nanostructured array may be a promising step in this direction.

  2. A UVC Device for Intra-luminal Disinfection of Catheters: In Vitro Tests on Soft Polymer Tubes Contaminated with Pseudomonas aeruginosa, Staphylococcus aureus, Escherichia coli and Candida albicans

    DEFF Research Database (Denmark)

    Bak, Jimmy; Begovic, Tanja; Bjarnsholt, Thomas

    2011-01-01

    light is possible. In this paper we present dose-response results using a newly developed UVC disinfection device, which can be connected to a Luer catheter hub. The device was tested on soft polymer tubes contaminated with a pallet of microorganisms, including Candida albicans, Staphylococcus aureus...

  3. QuantiFERON(R)-TB Gold In-Tube assay vs. tuberculin skin test in Indonesian children living with a tuberculosis case.

    NARCIS (Netherlands)

    Rutherford, M.E.; Nataprawira, M.; Yulita, I.; Apriani, L.; Maharani, W.; Crevel, R. van; Hill, P.C.; Alisjahbana, B.

    2012-01-01

    SETTING AND OBJECTIVES: The tuberculin skin test (TST) has limitations in diagnosing latent tuberculosis (TB) infection (LTBI). Interferon-gamma release assays may improve diagnostic accuracy. We compared QuantiFERON(R)-TB Gold In-Tube (QFT-GIT) and TST in Indonesian children. DESIGN: Children aged

  4. Effect of Resistance Tube Exercises on Kicking Accuracy, Vertical Jump and 40-Yard Technical Test in Competitive Football Players – An Experimental Study

    Directory of Open Access Journals (Sweden)

    Tirumala Alekhya

    2014-09-01

    Full Text Available Purpose. Kicking, jumping and agility are important skills in football. These activities require adequate lower limb strength, which can be enhanced with resistance training. The objective of the study was to evaluate the effect of resistance tube exercises on kicking accuracy, vertical jump performance and 40-yard technical test results in competitive football players. Methods. The study involved 23 competitive football players (11 males, 12 females aged from 18-20 years recruited from three different universities in Belgaum, Karnataka, India. Back heel kick accuracy, vertical jump height and 40-yard technical test time were evaluated before and after a 2-week resistance tube exercise program. Results. Significant improvements in post-intervention kicking accuracy were found when males and females were treated as a single group (p = 0.01. Vertical jump height also showed a highly significant post-intervention improvement in the males and for the combined group of males and females (p = 0.001. The 40-yard technical test values significantly improved in the females and in the combined results for males and females (p = 0.001. Conclusions. The two-week resistance tube exercise program was found to have an effect on kicking accuracy, vertical jump height and 40-yard technical test performance in competitive football players. Resistance tube exercises can thus be included as a component of a regular strength training program for such athletes.

  5. Weld examination on tube test specimen using TOFD; Untersuchungen mit TOFD an geschweissten Laengsnahtproben

    Energy Technology Data Exchange (ETDEWEB)

    Brekow, G.; Erhard, A. [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany). Labor fuer Ultraschallverfahren

    2000-07-01

    In contrast to the pulse echo technique, which is based on the sound field reflection at the flaw surface, the Time of Flight Diffraction (TOFD) technique uses the diffraction of the sound field at the flaw tips. For this purpose two angle beam probes for longitudinal waves are used in a pitch and catch arrangement. The transducers are positioned at both sides of the welding seam and are moved parallel to it during the measurement. The diffraction at the flaw tips causes different time of flight values with respect to the upper and lower flaw tip. Time dependent signals are stored in a series of A-scan pictures, which can finally be represented in a B-picture, which has to be interpreted. As investigations show there are additional useful information concerning defect size which can be given by TOFD, but pulse echo techniques with additional radiographic testing cannot be substituted by TOFD. (orig.) [German] Im Gegensatz zur Impuls-Echo-Technik, die im Wesentlichen auf der Reflexion am Fehler basiert, wird bei der Time-Of-Flight Diffraction Technique (TOFD-Technik) die Beugung der Schallwellen am Fehler zum Nachweis genutzt. Zwei Winkelpruefkoepfe fuer Longitudinalwellen sind in V-Durchschallung angeordnet. Die Pruefkoepfe befinden sich jeweils auf einer Seite der Schweissnaht und werden bei der Messung parallel zur Schweissnaht verschoben. Das ausgesandte Schallbuendel trifft auf Fehlerraender, an denen gebeugte Wellenanteile entstehen, die je nach Entstehungsort mit unterschiedlichen Schallaufzeiten empfangen, in hochfrequenten A-Bildern abgespeichert und fuer die Auswertung in B-Bildern dargestellt werden. Die Untersuchungen zeigen, dass die TOFD-Technik Beitraege zur Fehlergroessenabschaetzung liefert, aber keinesfalls die Impuls-Echo-Technik mit nachgeschalteter Roentgenpruefung ersetzen kann. (orig.)

  6. Simulation of TunneLadder traveling-wave tube cold-test characteristics: Implementation of the three-dimensional, electromagnetic circuit analysis code micro-SOS

    Science.gov (United States)

    Kory, Carol L.; Wilson, Jeffrey D.

    1993-01-01

    The three-dimensional, electromagnetic circuit analysis code, Micro-SOS, can be used to reduce expensive time-consuming experimental 'cold-testing' of traveling-wave tube (TWT) circuits. The frequency-phase dispersion characteristics and beam interaction impedance of a TunneLadder traveling-wave tube slow-wave structure were simulated using the code. When reasonable dimensional adjustments are made, computer results agree closely with experimental data. Modifications to the circuit geometry that would make the TunneLadder TWT easier to fabricate for higher frequency operation are explored.

  7. Multicenter evaluation of fully automated BACTEC Mycobacteria Growth Indicator Tube 960 system for susceptibility testing of Mycobacterium tuberculosis.

    Science.gov (United States)

    Bemer, Pascale; Palicova, Frantiska; Rüsch-Gerdes, Sabine; Drugeon, Henri B; Pfyffer, Gaby E

    2002-01-01

    The reliability of the BACTEC Mycobacteria Growth Indicator Tube (MGIT) 960 system for testing of Mycobacterium tuberculosis susceptibility to the three front-line drugs (isoniazid [INH], rifampin [RIF], and ethambutol [EMB]) plus streptomycin (STR) was compared to that of the BACTEC 460 TB system. The proportion method was used to resolve discrepant results by an independent arbiter. One hundred and ten strains were tested with an overall agreement of 93.5%. Discrepant results were obtained for seven strains (6.4%) with INH (resistant by BACTEC MGIT 960; susceptible by BACTEC 460 TB), for one strain (0.9%) with RIF (resistant by BACTEC MGIT 960; susceptible by BACTEC 460 TB), for seven strains (6.4%) with EMB (six resistant by BACTEC MGIT 960 and susceptible by BACTEC 460 TB; one susceptible by BACTEC MGIT 960 and resistant by BACTEC 460 TB), and for 19 strains (17.3%) with STR (resistant by BACTEC MGIT 960 and susceptible by BACTEC 460 TB). After resolution of discrepant results, the sensitivity of the BACTEC MGIT 960 system was 100% for all four drugs and specificity ranged from 89.8% for STR to 100% for RIF. Turnaround times were 4.6 to 11.7 days (median, 6.5 days) for BACTEC MGIT 960 and 4.0 to 10.0 days (median, 7.0 days) for BACTEC 460 TB. These data demonstrate that the fully automated and nonradiometric BACTEC MGIT 960 system is an accurate method for rapid susceptibility testing of M. tuberculosis.

  8. Tuberculin Skin Test and QuantiFERON(®)-TB Gold In-Tube Test for Diagnosing Latent Tuberculosis Infection among Thai Healthcare Workers.

    Science.gov (United States)

    Khawcharoenporn, Thana; Apisarnthanarak, Anucha; Sangkitporn, Somchai; Rudeeaneksin, Janisara; Srisungngam, Sopa; Bunchoo, Supranee; Phetsuksiri, Benjawan

    2016-05-20

    A cross-sectional study was conducted on the performance of the tuberculin skin test (TST) and QuantiFERON(®)-TB Gold In-Tube test (QFT-IT) for detecting latent tuberculosis infection among Thai healthcare workers (HCWs). Each HCW underwent both the TST and QFT-IT during the annual health screening. Among the 260 HCWs enrolled, the median age was 30 years (range 19-60 years), 92% were women, 64% were nurses and nurse assistants, 78% were Bacillus Calmette Guérin vaccinated, and 37% had previously taken the TST. Correlation between TST reaction size and the interferon-γ level was weak (r = 0.29; P tuberculosis diagnosis, the cut-off for TST reactivity with the best performance was ≥13 mm with a sensitivity, specificity, false positivity, and false negativity of 71%, 70%, 30%, and 29%, respectively (area under the curve 0.73; P < 0.001). The independent factor associated with a false reactive TST was a previous TST (adjusted odds ratio 1.83; P = 0.04). Our findings suggest that the QFT-IT may be the preferred test among HCWs with previous TST. In settings where the QFT-IT is not available, appropriate cut-offs for TST reactivity should be evaluated for use among HCWs.

  9. A new certified reference material for benzene measurement in air on a sorbent tube: development and proficiency testing.

    Science.gov (United States)

    Caurant, A; Lalère, B; Schbath, M-C; Stumpf, C; Sutour, C; Mace, T; Quisefit, J-P; Doussin, J-F; Vaslin-Reimann, S

    2010-11-01

    A certified matrix reference material (CRM) for the measurement of benzene in ambient air has been developed at Laboratoire National de Métrologie et d'Essais. The production of these CRMs was conducted using a gravimetric method fully traceable to the International System of Units. The CRMs were prepared by sampling an accurate mass of a gaseous primary reference material of benzene, using a high-precision laminar flowmeter and a mass flow controller, with a PerkinElmer sampler filled with Carbopack™ X sorbent. The relative standard deviations obtained for the preparation of a batch of 20 tubes loaded with 500 ng of benzene were below 0.2%. Each CRM is considered independent from the others and with its own certified value and an expanded uncertainty estimated to be within 0.5%, lower than the uncertainties of benzene CRMs already available worldwide. The stability of these materials was also established up to 12 months. These CRMs were implemented during proficiency testing, to evaluate the analytical performances of seven French laboratories involved in benzene air monitoring.

  10. Negative effect of smoking on the performance of the QuantiFERON TB gold in tube test

    Directory of Open Access Journals (Sweden)

    Aabye Martine G

    2012-12-01

    Full Text Available Abstract Background False negative and indeterminate Interferon Gamma Release Assay (IGRA results are a well documented problem. Cigarette smoking is known to increase the risk of tuberculosis (TB and to impair Interferon-gamma (IFN-γ responses to antigenic challenge, but the impact of smoking on IGRA performance is not known. The aim of this study was to evaluate the effect of smoking on IGRA performance in TB patients in a low and high TB prevalence setting respectively. Methods Patients with confirmed TB from Denmark (DK, n = 34; 20 smokers and Tanzania (TZ, n = 172; 23 smokers were tested with the QuantiFERON-TB Gold In tube (QFT. Median IFN-γ level in smokers and non smokers were compared and smoking was analysed as a risk factor for false negative and indeterminate QFT results. Results Smokers from both DK and TZ had lower IFN-γ antigen responses (median 0.9 vs. 4.2 IU/ml, p = 0.04 and 0.4 vs. 1.6, p  Conclusions Cigarette smoking was associated with false negative and indeterminate IGRA results in both a high and a low TB endemic setting independent of HIV status.

  11. Performance of a 4 Kelvin pulse-tube cooled cryostat with dc SQUID amplifiers for bolometric detector testing

    CERN Document Server

    Barron, Darcy; Keating, Brian; Quillin, Ron; Stebor, Nathan; Wilson, Brandon

    2013-01-01

    The latest generation of cosmic microwave background (CMB) telescopes is searching for the undetected faint signature of gravitational waves from inflation in the polarized signal of the CMB. To achieve the unprecedented levels of sensitivity required, these experiments use arrays of superconducting Transition Edge Sensor (TES) bolometers that are cooled to sub-Kelvin temperatures for photon-noise limited performance. These TES detectors are read out using low- noise SQUID amplifiers. To rapidly test these detectors and similar devices in a laboratory setting, we constructed a cryogenic refrigeration chain consisting of a commercial two-stage pulse-tube cooler, with a base temperature of 3 K, and a closed-cycle 3He/4He/3He sorption cooler, with a base temperature of 220 mK. A commercial dc SQUID system, with sensors cooled to 4 K, was used as a highly-sensitive cryogenic ammeter. Due to the extreme sensitivity of SQUIDs to changing magnetic fields, there are several challenges involving cooling them with puls...

  12. Eustachian tube function in children after insertion of ventilation tubes.

    NARCIS (Netherlands)

    Heerbeek, N. van; Ingels, K.J.A.O.; Snik, A.F.M.; Zielhuis, G.A.

    2001-01-01

    This study was performed to assess the effect of the insertion of ventilation tubes and the subsequent aeration of the middle ear on eustachian tube (ET) function in children. Manometric ET function tests were performed repeatedly for 3 months after the placement of ventilation tubes in 83 children

  13. Tracheostomy tubes.

    Science.gov (United States)

    Hess, Dean R; Altobelli, Neila P

    2014-06-01

    Tracheostomy tubes are used to administer positive-pressure ventilation, to provide a patent airway, and to provide access to the lower respiratory tract for airway clearance. They are available in a variety of sizes and styles from several manufacturers. The dimensions of tracheostomy tubes are given by their inner diameter, outer diameter, length, and curvature. Differences in dimensions between tubes with the same inner diameter from different manufacturers are not commonly appreciated but may have important clinical implications. Tracheostomy tubes can be cuffed or uncuffed and may be fenestrated. Some tracheostomy tubes are designed with an inner cannula. It is important for clinicians caring for patients with a tracheostomy tube to appreciate the nuances of various tracheostomy tube designs and to select a tube that appropriately fits the patient. The optimal frequency of changing a chronic tracheostomy tube is controversial. Specialized teams may be useful in managing patients with a tracheostomy. Speech can be facilitated with a speaking valve in patients with a tracheostomy tube who are breathing spontaneously. In mechanically ventilated patients with a tracheostomy, a talking tracheostomy tube, a deflated cuff technique with a speaking valve, or a deflated cuff technique without a speaking valve can be used to facilitate speech. Copyright © 2014 by Daedalus Enterprises.

  14. Comparative evaluation of slide agglutination and Widal tube agglutination test in detecting enteric fever among patients attending a tertiary care hospital in North India

    OpenAIRE

    Noor Jahan; Razia Khatoon; Amrita,; Sudhir Mehrotra; Swatantra Kumar

    2016-01-01

    Background: Enteric fever is a major public health problem with significant morbidity and mortality in developing countries. Although, isolation of causative organism from blood is the standard laboratory method, but due to frequent use of self-medication by patients, and its long turnaround time, it is seldom used, and enteric fever is usually diagnosed by using serological methods. Widal tube agglutination test is the standard serological test used, which is now a days replaced by slide agg...

  15. Comparison of tuberculin skin test and QuantiFERON®-TB Gold In-Tube for the diagnosis of childhood tuberculosis.

    Science.gov (United States)

    Uzunhan, Ozan; Törün, Selda Hançerli; Somer, Ayper; Salman, Nuran; Köksalan, Kaya

    2015-10-01

    Tuberculosis (TB) is an important worldwide ongoing health issue. To be able to control TB, one should not only cure active TB but also identify childhood TB patients who have the possibility to develop active disease in the future. The aim of this study was to compare a century-old tuberculin skin test (TST) and QuantiFERON-TB Gold In-Tube (QFT-GIT) test, developed as an alternative to TST and which has been claimed to be superior to TST in several ways, in the diagnosis of childhood TB. Fifty-three children with TB between 5 months and 17.5 years of age and 92 healthy children from the same age group with no risk factors for TB were recruited into the study. All children underwent TST and QFT-GIT test and their demographic, clinic and laboratory data were recorded. Data were analyzed using SPSS 14. A total of 53 patients were diagnosed with TB. Mean patient age was 8.5 ± 4.3 years (range, 5 months-17.5 years). A total of 41.7% of the patients were female. Sixteen of 53 patients had confirmation on culture. QFT-GIT test was positive in 16 and TST was positive in 15 among 16 children with culture-confirmed TB. The sensitivity of TST and QFT-GIT were 93.8% and 100.0%, and the specificity of TST and QFT-GIT were 100.0% and 97.8%, respectively. With regard to the 53 TB children including those without bacteriological confirmation, QFT-GIT was positive in 33 children, and TST was positive in 44 children. The sensitivity of TST and QFT-GIT was then 83.0% and 62.3%, and the specificity, 100.0% and 97.8%, respectively. Although positive QFT-GIT test is very significant for TB, negative results will not exclude TB infection. TST and QFT-GIT used together may provide more efficient results. © 2015 Japan Pediatric Society.

  16. Tuberculin skin test and QuantiFERON-TB Gold In-tube Test for latent tuberculosis in Thai HIV-infected adults.

    Science.gov (United States)

    Khawcharoenporn, Thana; Apisarnthanarak, Anucha; Phetsuksiri, Benjawan; Rudeeaneksin, Janisara; Srisungngam, Sopa; Mundy, Linda M

    2015-02-01

    Limited data exist for the performance of QuantiFERON-TB Gold In-tube Test (QFT-IT) in comparison to tuberculin skin test (TST) for detecting latent tuberculosis (LTB) in patients with human immunodeficiency virus (HIV) infection from tuberculosis (TB)-endemic Asia-Pacific countries. A cohort study of Thai HIV-infected patients without history of TB or LTB treatment was conducted from March 2012 through March 2013. Each patient underwent simultaneous TST and QFT-IT. Among the 150 enrolled subjects, the median age was 40 years (range 17-65), 53% were male, and the median CD4 count was 367 cells/μL (range 8-1290). Reactive TST and positive QFT-IT were 16% and 13%, respectively, with low concordance between tests (kappa = 0.26); correlation between TST reaction size and level of interferon-γ was moderate (r = 0.34). Independent factors associated with discordant results were long-term smoking (adjusted odds ratio (aOR) 5.74; P = 0.002) for TST-reactive, QFT-IT-negative subjects, and age greater than 52 years (aOR 5.56; P = 0.02) and female gender (aOR 4.40; P = 0.04) for TST non-reactive, QFT-IT-positive subjects. The level of agreement between both tests improved when using a TST cut-off of ≥ 10 mm (kappa = 0.39). In our setting where QFT-IT is available but has limited use due to cost, TST with a cut-off of 10 mm for reactivity should be the initial LTB test. HIV-infected women and persons older than 52 years with non-reactive TST and long-term smokers with reactive TST may benefit from subsequent QFT-IT. © 2014 Asian Pacific Society of Respirology.

  17. Design of Production Test IP-262-A-11-FP -- Evaluation of projection fuel elements for use in ribbed process tubes -- Demonstration loading

    Energy Technology Data Exchange (ETDEWEB)

    Hodgson, W.H.; Hall, R.E.

    1959-06-29

    For several years, a major category of fuel element failures has been the side corrosion type, characterized by localized accelerated fuel element jacket corrosion. Since it has been demonstrated {sup 1} that misalignment of fuel elements in a process tube will produce flow patterns and accelerated corrosion, termed ``hot spots``, failure to align the fuel elements in process tubes is considered a contributing factor in the production of side corrosion failures. Preliminary testing of both self-supporting and ``bumper`` fuel elements is underway. Data on the self-supporting fuel elements have demonstrated that the bridge-rail projections have sufficient support strength, do not of themselves create a corrosion problem and in actuality probably eliminate any hot-spot areas. Although one tube of bumper fuel elements in KW Reactor {sup 3} has been discharged, data are not as yet available. Potentially, the most sever corrosion conditions exist during the summer months when reactor inlet temperatures are high. It is desirable then, provided bumper fuel elements limit hot- spot corrosion, to evaluate the bumper concept for large scale use possibly by the summer of 1960. To accomplish this, a demonstration loading of the bumper type fuel elements must be underway by about July, 1959. The purpose of this report is to present the design of a test to evaluate the fabrication process and irradiation performance of fuel elements having projections, which may prevent misalignment in ribbed process tubes and meet the aforementioned goals.

  18. Effect of micronutrient deficiency on QuantiFERON-TB Gold In-Tube test and tuberculin skin test in diagnosis of childhood intrathoracic tuberculosis.

    Science.gov (United States)

    Mukherjee, A; Saini, S; Kabra, S K; Gupta, N; Singh, V; Singh, S; Bhatnagar, S; Saini, D; Grewal, H M S; Lodha, R

    2014-01-01

    Data on performance of QuantiFERON-TB Gold In-Tube test (QFT) and tuberculin skin test (TST) in children with active tuberculosis from high burden countries in the context of micronutrient deficiency are scarce. The objective of this study was to evaluate the effect of micronutrient deficiency on the performance of TST and QFT in children with intrathoracic tuberculosis. Children with probable intrathoracic tuberculosis underwent TST, QFT, gastric lavages and induced sputum examination for AFB (Acid-Fast Bacilli) smear and culture. Zinc, copper, ferritin and vitamin D were measured on stored serum samples. The study used cross-sectional data at initiation of anti-tubercular therapy. Three hundred and sixty-two children (median age 115.5 months (interquartile range: 73, 144), 200 (55.3%) girls) were enrolled in the study. Microbiological confirmation of tuberculosis could be obtained in 128 patients. TST and QFT were positive in 337 (93%) and 297 (82%) children, respectively. Performance of both the tests was unaffected by weight-for-age and height-for-age 'z-scores' or by serum copper levels. TST was not affected by serum zinc and ferritin levels. Children with negative QFT results had lower mean serum zinc level (P=0.01) and higher ferritin levels (P=0.007) as compared to those with positive test. Higher proportion of children with positive TST were vitamin D deficient/insufficient (P=0.003). Micronutrient status, especially serum levels of zinc, may influence the performance of QFT in children with intrathoracic tuberculosis. Considering the high prevalence of zinc deficiency in developing countries, QFT should be used cautiously for diagnosing tuberculosis.

  19. A Combined Raindrop Aggregate Destruction Test-Settling Tube (RADT-ST Approach to Identify the Settling Velocity of Sediment

    Directory of Open Access Journals (Sweden)

    Liangang Xiao

    2015-10-01

    Full Text Available The use of sediment settling velocity based on mineral grain size distribution in erosion models ignores the effects of aggregation on settling velocity. The alternative approach, wet-sieved aggregate size distribution, on the other hand, cannot represent all destructive processes that eroded soils may experience under impacting raindrops. Therefore, without considering raindrop impact, both methods may lead to biased predictions of the redistribution of sediment and associated substances across landscapes. Rainfall simulation is an effective way to simulate natural raindrop impact under controlled laboratory conditions. However, very few methods have been developed to integrate rainfall simulation with the settling velocity of eroded sediment. This study aims to develop a new proxy, based on rainfall simulation, in order to identify the actual settling velocity distribution of aggregated sediment. A combined Raindrop Aggregate Destruction Test-Settling Tube (RADT-ST approach was developed to (1 simulate aggregate destruction under a series of simulated rainfalls; and (2 measure the actual settling velocity distribution of destroyed aggregates. Mean Weight Settling Velocity (MWSV of aggregates was used to investigate settling behaviors of different soils as rainfall kinetic energy increased. The results show the settling velocity of silt-rich raindrop impacted aggregates is likely to be underestimated by at least six times if based on mineral grain size distribution. The RADT-ST designed in this study effectively captures the effects of aggregation on settling behavior. The settling velocity distribution should be regarded as an evolving, rather than steady state parameter during erosion events. The combined RADT-ST approach is able to generate the quasi-natural sediment under controlled simulated rainfall conditions and is adequately sensitive to measure actual settling velocities of differently aggregated soils. This combined approach provides

  20. Prothrombin time (PT)

    Science.gov (United States)

    PT; Pro-time; Anticoagulant-prothrombin time; Clotting time: protime; INR; International normalized ratio ... PT is measured in seconds. Most of the time, results are given as what is called INR ( ...

  1. Test of digital neutron–gamma discrimination with four different photomultiplier tubes for the NEutron Detector Array (NEDA)

    Energy Technology Data Exchange (ETDEWEB)

    Luo, X.L., E-mail: luo.xiaoliang@physics.uu.se [Department of Instrument Science and Technology, College of Mechatronics and Automation, National University of Defense Technology, Changsha (China); Department of Physics and Astronomy, Uppsala University, SE-75120 Uppsala (Sweden); Modamio, V. [INFN, Laboratori Nazionali di Legnaro, I-35020 Legnaro, Padova (Italy); Nyberg, J. [Department of Physics and Astronomy, Uppsala University, SE-75120 Uppsala (Sweden); Valiente-Dobón, J.J. [INFN, Laboratori Nazionali di Legnaro, I-35020 Legnaro, Padova (Italy); Nishada, Q. [Department of Physics and Astronomy, Uppsala University, SE-75120 Uppsala (Sweden); Angelis, G. de [INFN, Laboratori Nazionali di Legnaro, I-35020 Legnaro, Padova (Italy); Agramunt, J. [IFIC-CSIC, University of Valencia, Valencia (Spain); Egea, F.J. [IFIC-CSIC, University of Valencia, Valencia (Spain); Faculty of Engineering and Natural Sciences, Istanbul Sabahattin Zaim University, Istanbul (Turkey); Erduran, M.N.; Ertürk, S. [Nigde Universitesi, Fen-Edebiyat Falkültesi, Fizik Bölümü, Nigde (Turkey); France, G. de [GANIL, CEA/DSAM and CNRS/IN2P3, Bd Henri Becquerel, BP 55027, F-14076 Caen Cedex 05 (France); Gadea, A. [IFIC-CSIC, University of Valencia, Valencia (Spain); González, V. [Department of Electronic Engineering, University of Valencia, E-46071 Valencia (Spain); Hüyük, T. [IFIC-CSIC, University of Valencia, Valencia (Spain); Jaworski, G. [Faculty of Physics, Warsaw University of Technology, ul. Koszykowa 75, 00-662 Warszawa (Poland); Heavy Ion Laboratory, University of Warsaw, ul. Pasteura 5A, 02-093 Warszawa (Poland); Moszyński, M. [Heavy Ion Laboratory, University of Warsaw, ul. Pasteura 5A, 02-093 Warszawa (Poland); National Centre for Nuclear Research, A. Soltana 7, PL 05-400 Otwock-Swierk (Poland); and others

    2014-12-11

    A comparative study of the neutron–γ discrimination performance of a liquid scintillator detector BC501A coupled to four different 5 in. photomultiplier tubes (ET9390kb, R11833-100, XP4512 and R4144) was carried out. Both the Charge Comparison method and the Integrated Rise-Time method were implemented digitally to discriminate between neutrons and γ rays emitted by a {sup 252}Cf source. In both methods, the neutron–γ discrimination capabilities of the four photomultiplier tubes were quantitatively compared by evaluating their figure-of-merit values at different energy regions between 50 keVee and 1000 keVee. Additionally, the results were further verified qualitatively using time-of-flight to distinguish γ rays and neutrons. The results consistently show that photomultiplier tubes R11833-100 and ET9390kb generally perform best regarding neutron–γ discrimination with only slight differences in figure-of-merit values. This superiority can be explained by their relatively higher photoelectron yield, which indicates that a scintillator detector coupled to a photomultiplier tube with higher photoelectron yield tends to result in better neutron–γ discrimination performance. The results of this work will provide reference for the choice of photomultiplier tubes for future neutron detector arrays like NEDA.

  2. Cost analysis of tuberculin skin test and the QuantiFERON-TB Gold In-tube test for tuberculosis screening in a correctional setting in Dallas, Texas, USA.

    Science.gov (United States)

    Nijhawan, Ank E; Iroh, Princess A; Brown, Larry S; Winetsky, Daniel; Porsa, Esmaeil

    2016-10-12

    Tuberculosis (TB) disproportionately affects immigrants, HIV-infected individuals, and those living in crowded settings such as homeless shelters and correctional facilities. Although the majority of jails and prisons use a tuberculin skin test (TST) for latent tuberculosis infection (LTBI) screening, limited data exist on the clinical performance and costs of the TST compared to interferon gamma release assays (IGRAs) in this setting. A prospective pilot study comparing cost between TST and an IGRA (QuantiFERON Gold In-tube, QFT-GIT) for the detection of LTBI in a convenience sample of inmates entering the Dallas County Jail (DCJ) was conducted June-October 2014. Participants completed a risk questionnaire, TST placement, QFT-GIT testing, and were offered opt-out HIV-Ab testing. LTBI prevalence based on TST and QFT-GIT results, an evaluation of discordant results and a cost analysis are presented. A total of 529 subjects were enrolled. The majority were male (75 %), and 46 % were Black, 29 % White, and 24 % Hispanic. Most (85 %) had been previously incarcerated. Over 28 % of participants were released prior to TST reading, with paired QFT-GIT and TST results available for 351 subjects. Of these, nine (2.6 %) tested positive by TST and 47 (13.4 %) tested positive by QFT-GIT. It costs $23.27 more per inmate per year to screen with QFT-GIT than TST in this population, though the cost per LTBI case detected was nearly three times higher for TST than QFT-GIT ($1247 v $460). We found a substantially higher rate of QFT-GIT positivity compared to TST in this sample of individuals entering the Dallas County Jail. Although no gold standard exists, this finding may indicate under-recognized LTBI in this setting. QFT-GIT as an initial screening tool was more time-efficient, had four-fold fewer labor costs and provided results on more individuals when compared with the TST. The overall cost of QFT-GIT was $23.27 more per inmate per year, though the cost per LTBI case

  3. Comparison of the Staphylococcus QuickFISH BC test with the tube coagulase test performed on positive blood cultures for evaluation and application in a clinical routine setting.

    Science.gov (United States)

    Carretto, E; Bardaro, M; Russello, G; Mirra, M; Zuelli, C; Barbarini, D

    2013-01-01

    Many studies demonstrate that delayed proper therapy in bloodstream infections caused by Staphylococcus aureus increases the mortality rate, emphasizing the need to shorten the turnaround time for positive blood cultures. Different techniques are currently available, from phenotypic methods to more complex tests such as matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF), real-time PCR (RT-PCR), and fluorescence in situ hybridization using peptide nucleic acid probes (PNA FISH). This study evaluated the performance of the Staphylococcus QuickFISH BC test (QFT), a novel FISH methodology, compared with the direct tube coagulase test (DTCT) on blood cultures exhibiting Gram-positive cocci in clusters. A total of 173 blood cultures collected from 128 different patients were analyzed using the DTCT, evaluated after both 4 and 24 h, and the QFT. A total of 179 isolates were identified using the Vitek2 system. Thirty-five out of 35 Staphylococcus aureus were correctly identified by the QFT (sensitivity = 100%), with a specificity of 100% (no green fluorescence was detected for strains different from S. aureus). The DTCT was positive after 4 h for 28 out of the 35 samples (sensitivity = 80%) and after 24 h for 31 out of the 35 samples (sensitivity = 88.57%). Among the remaining 144 isolates, one was then identified as Corynebacterium striatum and two as Micrococcus luteus. QFT identified 139 out of the 141 coagulase-negative staphylococci (CoNS) (sensitivity = 98.58%), showing again a specificity of 100% (no fluorescent red signals were detected for strains different from CoNS). We also discuss also the implementation process of this methodology in our setting, with particular emphasis on the workflow and the cost-effectiveness.

  4. Predictive value of the tuberculin skin test and QuantiFERON-tuberculosis Gold In-Tube test for development of active tuberculosis in hemodialysis patients

    Science.gov (United States)

    Seyhan, Ekrem Cengiz; Gunluoglu, Gulşah; Gunluoglu, Mehmet Zeki; Tural, Seda; Sökücü, Sinem

    2016-01-01

    BACKGROUND: Hemodialysis (HD) patients are at increased risk of reactivation of latent tuberculosis infection (LTBI) compared with the general population. QuantiFERON-TB Gold (QFT-G) for LTBI detection is more promising than tuberculin skin test (TST) in HD patients. AIM: In our study, we evaluated the value of the TST and QFT-G In-Tube (QFG-IT) test in the development of active tuberculosis (TB), in the HD patients, and in healthy controls. METHODS: The study enrolled 95 HD patients and ninety age-matched, healthy controls. The TST and QFG-IT were performed. All the subjects were followed up 5 years for active TB disease. RESULTS: Compared to the healthy controls, a high prevalence of LTBI was found in the HD patients by QFG-IT (41% vs. 25%). However, no significant difference was detected by TST (32% vs. 31%). Four HD patients and one healthy control progressed to active TB disease within the 5-year follow-up. For active TB discovered subjects, QFG-IT was positive in all, but TST was positive in two (one patient and one healthy control). In HD patients; sensitivity, specificity, positive and negative predictive values of QFG-IT, and TST for active TB was 100% and 25%, 62% and 67%, 10%, and 3%, and 100% and 95%, respectively. Receiver operating curve analysis revealed that the results are significantly different (P = 0.04). CONCLUSION: QFG-IT test is a more useful diagnostic method than TST for detecting those who will progress to active TB in HD patients. PMID:27168859

  5. Real-ear measurements in conductive hearing loss: discrepancies between probe-tube microphone measurements and sound field test results.

    Science.gov (United States)

    Cleaver, V C

    1998-06-01

    This study was designed to investigate earlier observations that probe-tube microphone measurements of insertion gain overestimates the functional gain received from hearing aids by users with significant conductive hearing losses. This was originally thought to be due to artefacts in the probe-tube measurement caused by middle ear pathology, but is now believed to be the result of the bone conduction stimulation of the ear exposed to high intensities of airborne sound during sound field threshold measurements. Since the functional gain must relate to the true aided benefit in such cases, these findings suggest that probe-tube microphone measurements in ears with significant air-bone gaps should be interpreted with caution.

  6. Characterization of Multiaxial Stress-Strain Response of Tube Metal from Double-Sided Hydro-Bulging Test Based on Hosford's 1979 Yield Criterion

    Science.gov (United States)

    Cui, Xiao-Lei; Yang, Zhai-Ping; Wang, Xiao-Song

    2017-01-01

    To further explore the characterization of the multiaxial stress-strain responses of anisotropic tube metal from double-sided hydro-bulging tests, an analytical model for the equivalent stress and equivalent strain calculation was derived based on Hosford's 1979 yield criterion. Furthermore, thin-walled 5052-O aluminum alloy tubes were used to conduct the bulging experiment with an external pressure of 85 MPa. After the experimental data were substituted into the above analytical model, the Voce equation was used to fit the equivalent stress-strain relationship. It is concluded that the stress versus strain curves of the 5052-O tubes are strongly dependent on the loaded stress states, the adopted yield criteria, and the anisotropy coefficients. The external pressure of 85 MPa had little or no effect on the stress versus strain curves of the tubes, but the locations of the multiaxial stress versus strain curves were lower than that of the uniaxial stress versus strain curve. Moreover, the curve from Hosford's 1979 yield criterion not only had a higher saturation stress and material constant value than the curve from Mises and Hill's 1948 yield criteria but also had a dependence on the anisotropy coefficient.

  7. 试管婴儿产妇分娩前后心理特征分析%Test-tube baby maternal psychological characteristic analysis before and after childbirth

    Institute of Scientific and Technical Information of China (English)

    叶艳琴

    2014-01-01

    目的:了解试管婴儿产妇分娩前后心理特征的变化。方法随机抽取本院92例行试管婴儿技术的产妇为研究对象,采用症状自评量表(SCL-90)和艾森克人格问卷(EPQ)对其在分娩前后的心理状态进行评估。结果试管婴儿产妇分娩后在躯体化、人际关系敏感、抑郁、焦虑及敌对因子上的分数出现不同程度的降低(P<0.05),且EPQ中N分显著降低(t=3.487,P<0.01)。结论试管婴儿产妇在妊娠期间会出现部分心理特征变化,针对性地开展一些干预将有助于提升医疗服务质量。%Objective To explore the psychological characteristic of Test-tube baby maternal before and after childbirth. Methods Randomly selected 92 the test-tube baby maternas from our hospita as the research object, by the SCL-90 and EPQ to evaluate the psychological status before and after the birth. Results The test-tube baby maternal in somatization, interpersonal sensitivity, depression, anxiety and hostility factor on points appear different degree of lower (P < 0.05), and EPQ N decreased signiifcantly after childbirth than before childbirth (t = 3.487, P < 0.01). Conclusion The test-tube baby maternal can appear some psychological characteristics change during pregnancy, and some targeted intervention will help to improve medical service quality.

  8. Frottement en hydroformage de tube : caractérisation du frottement par le test d'expansion en matrice carrée

    OpenAIRE

    Abdelkefi, Abir

    2016-01-01

    The objective of this thesis is to study the possibility of characterizing the friction coefficient by an analytical model. First, the analytical model (Orban-Hu, 2007) has been programmed using "Matlab» software and has been validated by numerical simulation using "LS-Dyna" software. Then, experimental tests were carried out in order i) to characterize the mechanical properties of copper and ii) to study the tube hydroforming in a square section. As a result, the friction coefficient was cha...

  9. Construction and thermal efficiency test of 145m and 165m SpaceTube large-aperture parabolic trough collector prototypes

    Science.gov (United States)

    Rubia, Salvador Valenzuela; Schramm, Markus; Yildiz, Hülya; Marcotte, Patrick; Casero, David Martín; Magee, John Sebastian

    2016-05-01

    During 2013-2014 two prototype SpaceTube® 8.2 parabolic trough collector [1] were built, optically tested, and interconnected into an existing parabolic trough thermal testing loop at Abengoa's Solucar Platform in Spain. After this startup process more than 500 hours of testing at nominal operating conditions (393 °C maximum temperature and 40 bar maximum pressure) were accumulated, allowing verification of the real-world thermal performance against model predictions. Measured performances of both collectors met the optical performance target and no significant optical or assembly deficiency was found, resulting in verification of the collector(s) as ready to commercialize.

  10. Indoor test for thermal performance of the GE TC-100 liquid solar collector eight- and ten-tube configuration. [Marshall Space Flight Center solar simulator

    Science.gov (United States)

    1979-01-01

    The thermal performance of a liquid solar collector was tested in eight- and ten-tube configurations under simulated conditions. A time constant test and an incident angle modifier test were also conducted to determine the transient and incident angle effects on the collector. Performance loss with accessory covers is demonstrated. The gross collector area is about 17.4 ft sq without manifold and 19.1 ft sq with manifold. The collector weight is approximately 60 pounds empty and 75 pounds with manifold.

  11. Agreement between QuantiFERON®-TB Gold In-Tube and the tuberculin skin test and predictors of positive test results in Warao Amerindian pediatric tuberculosis contacts.

    Science.gov (United States)

    Verhagen, Lilly M; Maes, Mailis; Villalba, Julian A; d'Alessandro, Adriana; Rodriguez, Lazaro Perez; España, Mercedes F; Hermans, Peter W M; de Waard, Jacobus H

    2014-07-11

    Interferon-gamma release assays have emerged as a more specific alternative to the tuberculin skin test (TST) for detection of tuberculosis (TB) infection, especially in Bacille Calmette-Guérin (BCG) vaccinated people. We determined the prevalence of Mycobacterium tuberculosis infection by TST and QuantiFERON®-TB Gold In-Tube (QFT-GIT) and assessed agreement between the two test methods and factors associated with positivity in either test in Warao Amerindian children in Venezuela. Furthermore, progression to active TB disease was evaluated for up to 12 months. 163 HIV-negative childhood household contacts under 16 years of age were enrolled for TST, QFT-GIT and chest X-ray (CXR). Follow-up was performed at six and 12 months. Factors associated with TST and QFT-GIT positivity were studied using generalized estimation equations logistic regression models. At baseline, the proportion of TST positive children was similar to the proportion of children with a positive QFT-GIT (47% vs. 42%, p = 0.12). Overall concordance between QFT-GIT and TST was substantial (kappa 0.76, 95% CI 0.46-1.06). Previous BCG vaccination was not associated with significantly increased positivity in either test (OR 0.68, 95% CI 0.32-1.5 for TST and OR 0.51, 95% CI 0.14-1.9 for QFT-GIT). Eleven children were diagnosed with active TB at baseline. QFT-GIT had a higher sensitivity for active TB (88%, 95% CI 47-98%) than TST (55%, 95% CI 24-83%) while specificities were similar (respectively 58% and 55%). Five initially asymptomatic childhood contacts progressed to active TB disease during follow-up. Replacement of TST by the QFT-GIT for detection of M. tuberculosis infection is not recommended in this resource-constrained setting as test results showed substantial concordance and TST positivity was not affected by previous BCG vaccination. The QFT-GIT had a higher sensitivity than the TST for the detection of TB disease. However, the value of the QFT-GIT as an adjunct in diagnosing TB disease is

  12. Carbon supported nanoparticles Pt Ru (Pt Ru/C electrocatalysts) prepared using electron beam irradiation; Preparacao de nanoparticulas de PtRu suportadas em carbono (eletrocatalisadores PtRu/C) utilizando feixe de eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Dionisio F. da; Oliveira Neto, Almir; Pino, Eddy S.; Linardi, Marcelo; Spinace, Estevam V. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Programa de Celulas a Combustivel], e-mail: espinace@ipen.br, e-mail: dfsilva@ipen.br

    2006-07-01

    Carbon-supported Pt Ru (electrocatalysts PtRu/C nanoparticles) were prepared submitting a water/ethylene glycol mixture containing Pt(IV) and Ru(III) ions and the carbon support to electron beam irradiation. The PtRu/C electrocatalysts were characterized by EDX, XRD and cyclic voltammetry and tested for methanol electro-oxidation aiming fuel cell application. The obtained PtRu/C electrocatalysts were more active for methanol electro-oxidation than the commercial PtRu/C ETEK electrocatalyst at ambient temperature. (author)

  13. Carbon supported nanoparticles Pt Ru (Pt Ru/C electrocatalysts) prepared using electron beam irradiation; Preparacao de nanoparticulas de PtRu suportadas em carbono (eletrocatalisadores PtRu/C) utilizando feixe de eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Dionisio F. da; Oliveira Neto, Almir; Pino, Eddy S.; Linardi, Marcelo; Spinace, Estevam V. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Programa de Celulas a Combustivel], e-mail: espinace@ipen.br, e-mail: dfsilva@ipen.br

    2006-07-01

    Carbon-supported Pt Ru (electrocatalysts PtRu/C nanoparticles) were prepared submitting a water/ethylene glycol mixture containing Pt(IV) and Ru(III) ions and the carbon support to electron beam irradiation. The PtRu/C electrocatalysts were characterized by EDX, XRD and cyclic voltammetry and tested for methanol electro-oxidation aiming fuel cell application. The obtained PtRu/C electrocatalysts were more active for methanol electro-oxidation than the commercial PtRu/C ETEK electrocatalyst at ambient temperature. (author)

  14. FPGA Online Tracking Algorithm for the PANDA Straw Tube Tracker

    Science.gov (United States)

    Liang, Yutie; Ye, Hua; Galuska, Martin J.; Gessler, Thomas; Kuhn, Wolfgang; Lange, Jens Soren; Wagner, Milan N.; Liu, Zhen'an; Zhao, Jingzhou

    2017-06-01

    A novel FPGA based online tracking algorithm for helix track reconstruction in a solenoidal field, developed for the PANDA spectrometer, is described. Employing the Straw Tube Tracker detector with 4636 straw tubes, the algorithm includes a complex track finder, and a track fitter. Implemented in VHDL, the algorithm is tested on a Xilinx Virtex-4 FX60 FPGA chip with different types of events, at different event rates. A processing time of 7 $\\mu$s per event for an average of 6 charged tracks is obtained. The momentum resolution is about 3\\% (4\\%) for $p_t$ ($p_z$) at 1 GeV/c. Comparing to the algorithm running on a CPU chip (single core Intel Xeon E5520 at 2.26 GHz), an improvement of 3 orders of magnitude in processing time is obtained. The algorithm can handle severe overlapping of events which are typical for interaction rates above 10 MHz.

  15. FPGA Online Tracking Algorithm for the PANDA Straw Tube Tracker

    CERN Document Server

    Liang, Yutie; Galuska, Martin J; Gessler, Thomas; Kühn, Wolfgang; Lange, Jens Sören; Wagner, Milan N; Liu, Zhen'an; Zhao, Jingzhou

    2016-01-01

    A novel FPGA based online tracking algorithm for helix track reconstruction in a solenoidal field, developed for the PANDA spectrometer, is described. Employing the Straw Tube Tracker detector with 4636 straw tubes, the algorithm includes a complex track finder, and a track fitter. Implemented in VHDL, the algorithm is tested on a Xilinx Virtex-4 FX60 FPGA chip with different types of events, at different event rates. A processing time of 7 $\\mu$s per event for an average of 6 charged tracks is obtained. The momentum resolution is about 3\\% (4\\%) for $p_t$ ($p_z$) at 1 GeV/c. Comparing to the algorithm running on a CPU chip (single core Intel Xeon E5520 at 2.26 GHz), an improvement of 3 orders of magnitude in processing time is obtained. The algorithm can handle severe overlapping of events which are typical for interaction rates above 10 MHz.

  16. Pt nanoparticles on titania nanotubes prepared by vapor-phase impregnation-decomposition method

    Energy Technology Data Exchange (ETDEWEB)

    Encarnacion Gomez, C. [National Polytechnic Institute, Dept. of Metallurgical Eng., Mexico 07300 DF, AP 75-874 (Mexico); Vargas Garcia, J.R., E-mail: rvargasga@ipn.m [National Polytechnic Institute, Dept. of Metallurgical Eng., Mexico 07300 DF, AP 75-874 (Mexico); Toledo Antonio, J.A.; Cortes Jacome, M.A.; Angeles Chavez, C. [Petroleum Mexican Institute, Eje Central Lazaro Cardenas No. 152, Mexico 07730 DF (Mexico)

    2010-04-16

    Platinum (Pt) nanoparticles were prepared on titania nanotubes (TNTs) by vapor-phase impregnation-decomposition method using platinum acetylacetonate as precursor. TNTs and Pt precursor were mixed in 3:1 weight ratio before vapor-phase impregnation. The mixed powders were heated at 453 K for 10 min to evaporate the precursor in a horizontal tube quartz reactor at a total pressure of 66.6 kPa. Then, the impregnated TNTs were moved to a higher temperature zone (673 K) inside the tube reactor to achieve the precursor decomposition. HAADF-STEM observations, AAS and XPS results revealed that this method allows the formation of uniformly distributed Pt nanoparticles on the surface of TNTs with a narrow distribution of particle size (2.1 nm mean size). Pt nanoparticles remain mainly as Pt{sup 0} oxidation state with a Pt{sup 0}/Pt{sup 2+} atomic ratio of 3.9.

  17. Accurate Time-Dependent Traveling-Wave Tube Model Developed for Computational Bit-Error-Rate Testing

    Science.gov (United States)

    Kory, Carol L.

    2001-01-01

    The phenomenal growth of the satellite communications industry has created a large demand for traveling-wave tubes (TWT's) operating with unprecedented specifications requiring the design and production of many novel devices in record time. To achieve this, the TWT industry heavily relies on computational modeling. However, the TWT industry's computational modeling capabilities need to be improved because there are often discrepancies between measured TWT data and that predicted by conventional two-dimensional helical TWT interaction codes. This limits the analysis and design of novel devices or TWT's with parameters differing from what is conventionally manufactured. In addition, the inaccuracy of current computational tools limits achievable TWT performance because optimized designs require highly accurate models. To address these concerns, a fully three-dimensional, time-dependent, helical TWT interaction model was developed using the electromagnetic particle-in-cell code MAFIA (Solution of MAxwell's equations by the Finite-Integration-Algorithm). The model includes a short section of helical slow-wave circuit with excitation fed by radiofrequency input/output couplers, and an electron beam contained by periodic permanent magnet focusing. A cutaway view of several turns of the three-dimensional helical slow-wave circuit with input/output couplers is shown. This has been shown to be more accurate than conventionally used two-dimensional models. The growth of the communications industry has also imposed a demand for increased data rates for the transmission of large volumes of data. To achieve increased data rates, complex modulation and multiple access techniques are employed requiring minimum distortion of the signal as it is passed through the TWT. Thus, intersymbol interference (ISI) becomes a major consideration, as well as suspected causes such as reflections within the TWT. To experimentally investigate effects of the physical TWT on ISI would be

  18. Development and validation of a simulation tool dedicated to eddy current non destructive testing of tubes; Developpement d'un modele electromagnetique 3D pour la simulation du controle par Courants de Foucault de tubes en fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Reboud, Ch

    2006-09-15

    Eddy current testing (ECT) technique is widely used in industrial fields such as iron and steel industry. Dedicated simulation tools provide a great assistance for the optimisation of ECT processes. CEA and the Vallourec Research Center have collaborated in order to develop a simulation tool of ECT of tubes. The volume integral method has been chosen for the resolution of Maxwell equations in a stratified medium, in order to get accurate results with a computation time short enough to carry out optimisation or inversion procedures. A fast model has been developed for the simulation of ECT of non magnetic tubes using specific external probes. New flaw geometries have been modelled: holes and notches with flat bottom. Validations of the developments, which have been integrated to the CIVA platform, have been carried out using experimental data recorded in laboratory conditions and in. industrial conditions, successively. The integral equations derived are solved using the Galerkin variant of the method of moments with pulse functions as projection functions. In order to overcome some memory limitations, other projection functions have been considered. A new discretization scheme based on non-uniform B-Splines of degree 1 or 2 has been implemented, which constitutes an original contribution to the existing literature. The decrease of the mesh size needed to get a given accuracy on the result may lead to the simulation of more complex ECT configurations. (author)

  19. The special relativistic shock tube

    Science.gov (United States)

    Thompson, Kevin W.

    1986-01-01

    The shock-tube problem has served as a popular test for numerical hydrodynamics codes. The development of relativistic hydrodynamics codes has created a need for a similar test problem in relativistic hydrodynamics. The analytical solution to the special relativistic shock-tube problem is presented here. The relativistic shock-jump conditions and rarefaction solution which make up the shock tube are derived. The Newtonian limit of the calculations is given throughout.

  20. 一种自动化配置试管的标本采集解决方案%The Solution for Automated Configurable Test Tubes of Sample

    Institute of Scientific and Technical Information of China (English)

    余浩; 薛万国; 聂英娟; 田亚平

    2011-01-01

    The specimen collection system automatically configures test tubes using tube configuration machine, while tubes are pasted bar code label which are fit for the requirement of laboratory. The solution has reduced the workload of test contents inspection and checking steps, which avoided medical negligence caused by wrong type tube and wrong patient information, improved the efficiency of the sample collection. The solution provided basic conditions for laboratory automation. In addition, the key information of sample is recorded, which can be tracked on the specimen collection and quality control. Meanwhile, the article made the other 2 application mode according to actual situation of hospital in China.%标本采集系统使用了采血管配置机,利用配置机完成检验中所需试管的自动化配置,同时在所配置的试管上自动粘贴满足实验要求的条形码标签.该方案减少了工作人员对试管类型与检验内容的人工挑选和核对环节,避免由于病人信息标识错误及错用试管类型导致的医疗差错,提高了整个采血工作的效率,为实验室全自动化检验准备了基础条件.另外,系统对标本采集中的关键信息进行了记录,据此可对标本采集工作进行追踪和质量控制.同时,根据国内医院的实际情况,提出了自动摆管机的另外2种应用方式.

  1. The study on carbon nanotubes-supported Pt catalysts for PEMFC

    Institute of Scientific and Technical Information of China (English)

    朱捷; 朱红; 康晓红; 葛奉娟; 杨玉国

    2004-01-01

    Carbon nanotube-supported-platinum (Pt/CNTs) and carbon-supported-platinum (Pt/C) catalysts were prepared by in situ chemical reduction method and analyzed by TEM and XRD. Then the experiments were carried out to test the performance of PEMFCs with the Pt electrodes. The results showed that in both catalyst, Pt was of small particle size (about 4 nm) and Pt/CNTs exhibited higher catalytic activity than Pt/C.

  2. Direct determination of the ionization energies of PtC, PtO, and PtO2 with VUV radiation.

    Science.gov (United States)

    Citir, Murat; Metz, Ricardo B; Belau, Leonid; Ahmed, Musahid

    2008-10-02

    Photoionization efficiency curves were measured for gas-phase PtC, PtO, and PtO2 using tunable vacuum ultraviolet (VUV) radiation at the Advanced Light Source. The molecules were prepared by laser ablation of a platinum tube, followed by reaction with CH4 or N2O and supersonic expansion. These measurements provide the first directly measured ionization energy for PtC, IE(PtC) = 9.45 +/- 0.05 eV. The direct measurement also gives greatly improved ionization energies for the platinum oxides, IE(PtO) = 10.0 +/- 0.1 eV and IE(PtO2) = 11.35 +/- 0.05 eV. The ionization energy connects the dissociation energies of the neutral and cation, leading to greatly improved 0 K bond dissociation energies for the neutrals: D0(Pt-C) = 5.95 +/- 0.07 eV, D0(Pt-O) = 4.30 +/- 0.12 eV, and D0(OPt-O) = 4.41 +/- 0.13 eV, as well as enthalpies of formation for the gas-phase molecules DeltaH(0)(f,0)(PtC(g)) = 701 +/- 7 kJ/mol, DeltaH(0)(f,0)(PtO(g)) = 396 +/- 12 kJ/mol, and DeltaH(0)(f,0)(PtO2(g)) = 218 +/- 11 kJ/mol. Much of the error in previous Knudsen cell measurements of platinum oxide bond dissociation energies is due to the use of thermodynamic second law extrapolations. Third law values calculated using statistical mechanical thermodynamic functions are in much better agreement with values obtained from ionization energies and ion energetics. These experiments demonstrate that laser ablation production with direct VUV ionization measurements is a versatile tool to measure ionization energies and bond dissociation energies for catalytically interesting species such as metal oxides and carbides.

  3. Gravity Bias in Young and Adult Chimpanzees ("Pan Troglodytes"): Tests with a Modified Opaque-Tubes Task

    Science.gov (United States)

    Tomonaga, Masaki; Imura, Tomoko; Mizuno, Yuu; Tanaka, Masayuki

    2007-01-01

    Young human children at around 2 years of age fail to predict the correct location of an object when it is dropped from the top of an S-shape opaque tube. They search in the location just below the releasing point (Hood, 1995). This type of error, called a "gravity bias", has recently been reported in dogs and monkeys. In the present study, we…

  4. Invisibility and PT symmetry

    OpenAIRE

    MOSTAFAZADEH, Ali

    2013-01-01

    PHYSICAL REVIEW A 87, 012103 (2013) Invisibility and PT symmetry Ali Mostafazadeh* Department of Mathematics, Koc¸ University, Sarıyer 34450, Istanbul, Turkey (Received 9 July 2012; published 3 January 2013) For a general complex scattering potential defined on a real line, we show that the equations governing invisibility of the potential are invariant under the combined action of parity and time-reversal (PT ) transformation. We determine the PT -symmetric as well as no...

  5. Gastrostomy Tube (G-Tube)

    Science.gov (United States)

    ... the recovery room, sometimes called the "post-op" (post-operative) room or PACU (post-anesthesia care unit), and ... site; discharge that's yellow, green, or foul-smelling; fever) excessive bleeding or drainage from the tube site ...

  6. Easy synthesis approach of Pt-nanoparticles on polyaniline surface: an efficient electro-catalyst for methanol oxidation reaction

    Science.gov (United States)

    Mondal, Sanjoy; Malik, Sudip

    2016-10-01

    A facile room temperature and surfactant free synthesis of platinum nanoparticles (Pt-NPs) on benzene tetra-carboxylic acid doped polyaniline (BDP) tube has been successfully demonstrated by solution dipping method. Preparation of Pt-NPs has been done through a red-ox reaction between BDP tubes and Pt-salt, as BDP itself acts as nontoxic reducing agent as well as template cum stabilizer for Pt-NPs. In BDP@Pt composites, ∼2.5 ± 0.5 nm spherical shaped Pt-NPs as observed from TEM studies are nicely decorated on the surface of BDP. The population or the loading density of Pt-NPs on BDP tube is greatly controlled by changing the w/w ratio of BDP to H2PtCl6. Synthesized BDP@Pt composites are subsequently employed as an efficient electro-catalyst for methanol oxidation reaction (MOR) in acidic medium. Furthermore, the observed catalytic activity is consequently ∼12 times higher than that of commercially available Pt/C catalyst. Depending on the loading density of Pt-NPs on BDP tubes, the efficiency and carbon monoxide (CO) tolerance ability of composites have been explored.

  7. Model test of reactor vessel wall. Pt. 2. Test performance, measurement and partial evaluation; Modellkoerperversuch zur Reaktortankwand. T. 2; Versuchsdurchfuehrung, Messung und Teilauswertung

    Energy Technology Data Exchange (ETDEWEB)

    Maile, K.; Eckert, W.; Theofel, H.; Purper, H.

    1992-07-01

    Due to test interruption because of cut promotion means, the original objective of the project - verification of reactor wall design - could not be achieved because by that point in time the slabs had not yet failed (DIN 1.4948 = X 6 CrNi 18 11). Considering, however, the elongation curve, in particular that of the faulty slab, failure at an earlier stress cycle value than calculated is highly probable. (orig./HP) [Deutsch] Aufgrund des foerderungsbedingten Abbruchs der Versuche konnte die urspruengliche Zielsetzung des Vorhabens - Verifizierung der Auslegung der Reaktorwand - nicht erreicht werden, da ein Versagen der Platten bis zu diesem Zeitpunkt noch nicht vorlag (DIN 1.4948 = X 6 CrNi 18 11). Betrachtet man jedoch den Dehnungsverlauf insbesondere in der Platte mit Fehlern ist zu vermuten, dass ein Versagen zu einer frueheren Lastspielzahl als berechnet sehr wahrscheinlich ist. (orig./HP)

  8. Scale-up of counter-current chromatography: demonstration of predictable isocratic and quasi-continuous operating modes from the test tube to pilot/process scale.

    Science.gov (United States)

    Sutherland, Ian; Hewitson, Peter; Ignatova, Svetlana

    2009-12-11

    Predictable scale-up from test tube derived distribution ratios and analytical-scale sample loading optimisation is demonstrated using a model sample system of benzyl alcohol and p-cresol in a heptane:ethyl acetate:methanol:water phase system with the new 18 L Maxi counter-current chromatography centrifuge. The versatility of having a liquid stationary phase with its high loading capacity and flexible operating modes is demonstrated at two different scales by separating and concentrating target compounds using a mixture of caffeine, vanillin, naringenin and carvone using a quasi-continuous technique called intermittent counter-current extraction.

  9. 多功能验管装置的研制与应用%Development and Application of Multifunctional Tubing Testing Device

    Institute of Scientific and Technical Information of China (English)

    户贵华; 赵杰; 童文星; 蒋建华; 梁超; 王玉环

    2012-01-01

    为了解决不同现场条件下验管和泄压的问题,提高分层注水管柱密封性和封隔器密封性判别的准确率,研制了多功能验管装置。该验管装置集验管、泄流、打捞功能于一体,并可在验管后通过打捞或反洗到地面,不需要起出井下管柱。另外,可通过上提或撞击方式实现上部和下部压力的连通,避免因层间差异导致打捞载荷增加的不足,提高打捞成功率,并可实现泄流,减轻对环境的污染。现场应用结果表明,该验管装置设计合理,工艺成功率高,可满足不同现场条件下验管、打捞和泄流的要求,应用效果良好。%The multifunctional tubing testing device was developed to deal and pressure relief under different field conditions. The device integrates fishing. It can get onto ground through fishing or backwash after tubing testing with the requirement of tubing testubing testing, flow discharge and with no need of tripping the downhole string. In addition the connection of upper and lower pressures can be achieved through pulling or collision, avoiding insufficient fishing load increase caused by interlayer difference, improving the success rate of fishing, achieving flow discharge and reducing environmental pollution. The field application shows that the device is reason- able in design with a high technological success rate. It can meet the needs of tubing testing, fishing and flow discharge in different field conditions with desirable effects of application.

  10. Preparation of PtSn/C, PtRu/C, PtRh/C, PtRuRh/C and PtSnRh/C electrocatalysts using an alcohol-reduction process for methanol and ethanol oxidation; Preparacao e caracterizacao de eletrocatalisadores PtRu, PtSn, PtRh, PtRuRh e PtSnRh para oxidacao direta de alcoois em celulas a combustivel tipo PEM utilizando a metodologia da reducao por alcool

    Energy Technology Data Exchange (ETDEWEB)

    Dias, Ricardo Rodrigues

    2009-07-01

    In this work, Pt/C, PtRh (90:10), PtRh/C (50:50), PtSn/C (50:50), PtRu (50:50)/C, PtRuRh/C (50:40:10) and PtSnRh/C (50:40:10) were prepared by an alcohol-reduction process with metal loading of 20 wt.% using H{sub 2}PtCl{sub 6}.6H{sub 2}O (Aldrich), SnCl{sub 2}.2H{sub 2}O (Aldrich),and RhCl{sub 2}.XH{sub 2}O (Aldrich) as metals sources and Vulcan XC72 as support. The electrocatalysts were characterized by EDX, XRD and cyclic voltammetry (CV). The electro-oxidation of ethanol was studied by CV, chronoamperomety at room temperature in acid medium and tests at 100 deg C on a single cell of a direct methanol or ethanol fuel cell. The EDX analysis showed that the metal atomic ratios of the obtained electrocatalysts were similar to the nominal atomic ratios used in the preparation. The diffractograms of electrocatalysts prepared showed four peaks at approximately 2{theta} =40 deg, 47 deg, 67 deg and 82 deg, which are associated with the (111), (200), (220) and (311) planes, respectively, of a face cubic-centered (fcc) structure characteristic of platinum and platinum alloys. The average crystallite sizes using the Scherrer equation and the calculated values were in the range of 2-3 nm. For Pt Sn/C and PtSnRh/C two additional peaks were observed at 2 = 34 deg and 52 deg that were identified as a SnO{sub 2} phase. Pt Sn/C (50:50) and PtSnRh/C (50:40:10) electro catalyst showed the best performance for ethanol oxidation at room temperature. For methanol oxidation at room temperature Pt Ru/C, Pt Sn/C and PtRuRh/C electrocatalysts showed the best performance. Tests at 100 deg C on a single cell of a direct ethanol fuel cell PtSnRh/C showed the best performance, for methanol oxidation PtRuRh/C showed the best performance. (author)

  11. Using a nasogastric tube.

    Science.gov (United States)

    Candy, C

    1986-09-01

    This discussion of the use of a nasogastric tube covers the equipment needed, the method, rehydration and feeding, prolonged nasogastric feeding, and stopping nasogastric feeding. A nasogastric tube is useful when children are unable to drink safely and in sufficient amounts for any of the following reasons: severe dehydration; if intravenous (IV) therapy is unavailable; low birth weight infants; or the child is drowsy or vomiting. Severely malnourished children may be fed initially in this way if they are too weak or anorexic to eat or drink normally. The following equipment is needed: nasogastric tube; lubricating fluid; a syringe; blue litmus paper, if available; adhesive tape; stethoscope if available; and fluid to be given. Explain to the child's parents and the child, if old enough to understand, what will be done; lie infants flat; measure the approximate length from the child's nostril to the ear lobe and then to the top of the abdomen with the tube and mark the position; clean the nostrils to remove the mucus, and lubricate the tip of the tube and gently insert into the nostril; give the child a drink of water if he or she is conscious; continue to pass the tube down until the position marked reaches the nostril; use the syringe to suck up some fluid and test with blue litmus paper to check that the tube is in the stomach; and inject 5-10 ml of fluid (saline or oral rehydration solution, not milk formula) by syringe if satisfied the tube is in the correct position. Where possible, give a continuous drip of fluid. If this is not possible, give frequent small amounts using the syringe as a funnel. If feeding continues for more than 24 hours, clean the nostrils daily with warm water and change the tube to the other nostril every few days. Also keep the mouth very clean with a dilute solution of 8% sodium bicarbonate, if available, or citrus fruit juice. To remove the tube, remove the adhesive tape, take the tube out gently and smoothly, and offer the child a

  12. Magnesium tube hydroforming

    Energy Technology Data Exchange (ETDEWEB)

    Liewald, M.; Pop, R. [Institute for Metal Forming Technology (IFU), Stuttgart (Germany)

    2008-04-15

    Magnesium alloys reveal a good strength-to-weight ratio in the family of lightweight metals and gains potential to provide up to 30% mass savings compared to aluminium and up to 75 % compared to steel. The use of sheet magnesium alloys for auto body applications is however limited due to the relatively low formability at room temperature. Within the scope of this paper, extruded magnesium tubes, which are suitable for hydroforming applications, have been investigated. Results obtained at room temperature using magnesium AZ31 tubes show that circumferential strains are limited to a maximal value of 4%. In order to examine the influence of the forming temperature on tube formability, investigations have been carried out with a new die set for hot internal high pressure (IHP) forming at temperatures up to 400 C. Earlier investigations with magnesium AZ31 tubes have shown that fractures occur along the welding line at tubes extruded over a spider die, whereby a non-uniform expansion at bursting with an elongation value of 24% can be observed. A maximum circumferential strain of approx. 60% could be attained when seamless, mechanically pre-expanded and annealed tubes of the same alloy have been used. The effect of annealing time on materials forming properties shows a fine grained structure for sufficient annealing times as well as deterioration with a large increase at same time. Hence, seamless ZM21 tubes have been used in the current investigations. With these tubes, an increased tensile fracture strain of 116% at 350 C is observed as against 19% at 20 C, obtained by tensile testing of milled specimens from the extruded tubes. This behaviour is also seen under the condition of tool contact during the IHP forming process. To determine the maximum circumferential strain at different forming temperatures and strain rates, the tubes are initially bulged in a die with square cross-section under plane stress conditions. Thereafter, the tubes are calibrated by using an

  13. Temperature increase of Zircaloy-4 cladding tubes due to plastic heat dissipation during tensile tests at 0.1-10 s-1 strain rates

    Science.gov (United States)

    Hellouin de Menibus, Arthur; Auzoux, Quentin; Besson, Jacques; Crépin, Jérôme

    2014-11-01

    This study is focused on the impact of rapid Reactivity Initiated Accident (RIA) representative strain rates (about 1 s-1 NEA, 2010) on the behavior and fracture of unirradiated cold work stress relieved Zircaloy-4 cladding tubes. Uniaxial ring tests (HT) and plane strain ring tensile tests (PST) were performed in the 0.1-10 s-1 strain rate range, at 25 °C. The local temperature increase due to plastic dissipation was measured with a high-speed infrared camera. Limited temperature increases were measured at 0.1 s-1 strain rate. Limited but not strongly localized temperature increases were measured at 1 s-1. Large temperature increase were measured at 5 and 10 s-1 (142 °C at 5 s-1 strain rate in HT tests). The local temperature increase induced heterogeneous temperature fields, which enhanced strain localization and resulted in a reduction of the plastic elongation at fracture.

  14. Pt Ru/C electrocatalysts prepared using electron beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Dionisio Furtunato da; Oliveira Neto, Almir; Pino, Eddy Segura; Brandalise, Michele; Linardi, Marcelo; Spinace, Estevam Vitorio [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: espinace@ipen.br

    2007-10-15

    Pt Ru/C electrocatalysts (carbon-supported Pt Ru nanoparticles) were prepared submitting water/ethylene glycol mixtures containing Pt(IV) and Ru(III) ions and the carbon support to electron beam irradiation. The electrocatalysts were characterized by energy dispersive X ray analysis (EDX), X ray diffraction (XRD) and cyclic voltammetry and tested for methanol electro-oxidation aiming fuel cell application. The obtained Pt Ru/C electrocatalysts showed superior performance for methanol electro-oxidation at room temperature compared to commercial Pt Ru/C electrocatalyst. (author)

  15. Fabrication of Pt deposited on carbon nanotubes and performance of its polymer electrolyte membrane fuel cells

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    A new method of depositing nano-sized Pt particles on the surface of the carbon nano-tubes was introduced, and the performance of Pt/carbon nanotube compound on polymer electrolyte membrane fuel cells was measured. The experimental results show that the fine platinum particles (about 3 nm) were well dispersed on carbon nanotubes, which demonstrates the excellent catalytic properties of the Pt/CNTs compound in polymer electrolyte membrane fuel cells.

  16. 采血管中添加剂对血样中乙醇含量的影响%Effects of Additives in Blood Collection Tubes on Testing the Alcohol Concentra-tion in Blood Samples

    Institute of Scientific and Technical Information of China (English)

    刘冬娴; 贺江南

    2014-01-01

    Objective To discuss blood collection tubes with different additives and their effects on the testing results of alcohol concentration in blood sam ples. Methods Blood sam ples from 10 volunteers were collected 2 hours after drinking with seven different types of disposable vacuum blood collection tubes, including ordinary tube without anticoagulant, coagulant tube, separating gel-coagulant tube, sodi-um citrate (1∶4) tube, sodium citrate (1∶9) tube, sodium citrate (9∶1) tube and EDTA-K2 tube. The al-cohol concentrations in these blood sam ples were analyzed by headspace gas chrom atography. Results The concentration testing results of the sam e blood sam ples in different types of tubes were different from one to another. The sequence was as follows:separating gel-coagulant tube>coagulant tube>ordi-nary tube without anticoagulant>EDTA-K2 tube>sodium citrate (1∶9) tube>sodium citrate (1∶4) tube, whereas the results of the sam e blood sam ple in sodium citrate (1∶9) tube and sodium citrate (9∶1) tube showed no obvious difference. Conclusion It is better to collect a suspicious drunk driver’s blood sam-ple using a disposable vacuum blood collection tube, with the EDTA-K2 tube being preferred.%目的:探讨不同种类采血管对血样中乙醇含量检测结果的影响。方法分别用7种一次性真空采血管[无抗凝剂管、促凝剂管、分离胶-促凝剂管、枸橼酸钠(1∶4)管、枸橼酸钠(1∶9)管、柠檬酸钠(9∶1)管、EDTA-K2管]采集10名志愿者饮酒后2 h血液,用顶空气相色谱法检测血样中乙醇含量。结果相同血样用不同的采血管,其乙醇含量检测结果不同,依次为分离胶-促凝剂管>促凝剂管>无抗凝剂管>EDTA-K2管>枸橼酸钠(1∶9)管>枸橼酸钠(1∶4)管,柠檬酸钠(9∶1)管与枸橼酸钠(1∶9)管检测结果基本一致。结论采集涉嫌酒后驾驶的驾驶员血样,应选用一次性真空采血管,首选EDTA-K2管。

  17. Ánodos de Pt-Ru y Pt-Ir para Celdas de Combustible Alimentadas con Metano y Propano Directo Pt-Ru and Pt-Ir Anodes for Direct Methane and Propane Proton Exchange Membrane Fuel Cells

    Directory of Open Access Journals (Sweden)

    Bibian A Hoyos

    2007-01-01

    Full Text Available En este trabajo se evalúa el efecto de la temperatura en el desempeño de celdas de combustible de membrana de intercambio protónico alimentadas con metano y propano, utilizando oxígeno como alimentación en el cátodo. Para la oxidación de los combustibles en los ánodos, se probaron cinco catalizadores soportados en carbón: Pt, Pt85Ru15, Pt50Ru50, Pt90Ir10 y Pt50Ir50. Como catalizador en el cátodo se usó platino puro soportado en carbón. El desempeño de las celdas de combustible fue evaluado mediante curvas de polarización obtenidas a partir de los datos corriente-potencial. Los resultados indican que la oxidación de metano se ve favorecida a altas temperaturas sobre los catalizadores Pt90/Ir10, Pt50/Ir50 y Pt50/Ru50. A bajas temperaturas los mejores catalizadores resultaron ser Pt y Pt85/Ru15. La mezcla bimetálica Pt85/Ru15 fue la que presentó mejor desempeño para llevar a cabo la oxidación de propano a 30 °C.In this paper, the effect of temperature in the performance of proton exchange membrane fuel cells feed with methane and propane, using oxygen as feed to the cathode, is presented. For the fuel oxidation in the anodes, five carbon supported catalysts were tested: Pt, Pt85/Ru15, Pt50/Ru50, Pt90/Ir10, and Pt50/Ir50. Carbon-supported pure platinum was used as catalysts in the cathode side. The performance of the fuel cells was evaluated by polarization curves obtained from the current-potential data. Results indicate that methane oxidation is favoured at high temperatures on the Pt90/Ir10, Pt50/Ir50 and Pt50/Ru50 catalysts. At low temperatures the best catalysts were Pt and Pt85/Ru15. The Pt85/Ru15 bimetallic mixture showed the best performance to carry out propane oxidation at 30 °C.

  18. Steam generator tube integrity program

    Energy Technology Data Exchange (ETDEWEB)

    Dierks, D.R.; Shack, W.J. [Argonne National Laboratory, IL (United States); Muscara, J.

    1996-03-01

    A new research program on steam generator tubing degradation is being sponsored by the U.S. Nuclear Regulatory Commission (NRC) at Argonne National Laboratory. This program is intended to support a performance-based steam generator tube integrity rule. Critical areas addressed by the program include evaluation of the processes used for the in-service inspection of steam generator tubes and recommendations for improving the reliability and accuracy of inspections; validation and improvement of correlations for evaluating integrity and leakage of degraded steam generator tubes, and validation and improvement of correlations and models for predicting degradation in steam generator tubes as aging occurs. The studies will focus on mill-annealed Alloy 600 tubing, however, tests will also be performed on replacement materials such as thermally-treated Alloy 600 or 690. An overview of the technical work planned for the program is given.

  19. 基于ANSYS的某型飞机液压管路应力测试%Stress Test of Hydraulic Tubing in Aircraft Based on ANSYS

    Institute of Scientific and Technical Information of China (English)

    史杰; 胡文

    2014-01-01

    In order to minimize the quantity of strain gauges and improve the accuracy in the stress test of hydraulic tubing.Stress analysis based on ANSYS before the test is proposed in this paper. The CATIA mockups of the hydraulic tubing are imported to ANSYS and the stress analysis is carried out by Workbench. The locations of sensors are optimized according to the calculated stress distribution. The data measured in the test is used to optimize the finite element model. The quantity of strain gauges used in the stress test can be minimized and accuracy can be improved in the field test by implementing the proposed method.%为了优化液压管路应力测试,减少测点数量,提高测试准确度,提出在应力测试前用ANSYS对管路进行受力分析,试验后用试验数据进行模型修正。通过对管路进行三维建模,将模型导入ANSYS,分析管路振动时应力分布,根据受力情况确定传感器的安装位置。后将测得的数据修正模型参数,通过模型计算最大应力。通过ANSYS优化应力测试,减少了传感器布置的数量,提高了测试的准确度。

  20. Pt3 Co Octapods as Superior Catalysts of CO2 Hydrogenation.

    Science.gov (United States)

    Khan, Munir Ullah; Wang, Liangbing; Liu, Zhao; Gao, Zehua; Wang, Shenpeng; Li, Hongliang; Zhang, Wenbo; Wang, Menglin; Wang, Zhengfei; Ma, Chao; Zeng, Jie

    2016-08-08

    As the electron transfer to CO2 is a critical step in the activation of CO2 , it is of significant importance to engineer the electronic properties of CO2 hydrogenation catalysts to enhance their activity. Herein, we prepared Pt3 Co nanocrystals with improved catalytic performance towards CO2 hydrogenation to methanol. Pt3 Co octapods, Pt3 Co nanocubes, Pt octapods, and Pt nanocubes were tested, and the Pt3 Co octapods achieved the best catalytic activity. Both the presence of multiple sharp tips and charge transfer between Pt and Co enabled the accumulation of negative charges on the Pt atoms in the vertices of the Pt3 Co octapods. Moreover, infrared reflection absorption spectroscopy confirmed that the high negative charge density at the Pt atoms in the vertices of the Pt3 Co octapods promotes the activation of CO2 and accordingly enhances the catalytic activity.

  1. 0.22 THz wideband sheet electron beam traveling wave tube amplifier: Cold test measurements and beam wave interaction analysis

    Energy Technology Data Exchange (ETDEWEB)

    Baig, Anisullah; Gamzina, Diana; Barchfeld, Robert; Domier, Calvin; Barnett, Larry R.; Luhmann, Neville C. Jr. [Department of Electrical and Computer Engineering, University of California, Davis, California 95616 (United States)

    2012-09-15

    In this paper, we describe micro-fabrication, RF measurements, and particle-in-cell (PIC) simulation modeling analysis of the 0.22 THz double-vane half period staggered traveling wave tube amplifier (TWTA) circuit. The TWTA slow wave structure comprised of two sections separated by two sever ports loaded by loss material, with integrated broadband input/output couplers. The micro-metallic structures were fabricated using nano-CNC milling and diffusion bonded in a three layer process. The 3D optical microscopy and SEM analysis showed that the fabrication error was within 2-3 {mu}m and surface roughness was measured within 30-50 nm. The RF measurements were conducted with an Agilent PNA-X network analyzer employing WR5.1 T/R modules with a frequency range of 178-228 GHz. The in-band insertion loss (S{sub 21}) for both the short section and long section (separated by a sever) was measured as {approx}-5 dB while the return loss was generally around {approx}-15 dB or better. The measurements matched well with the S-matrix simulation analysis that predicted a 3 dB bandwidth of {approx}45 GHz with an operating frequency at 220 GHz. However, the measured S{sub 21} was {approx}3 dB less than the design values, and is attributed to surface roughness and alignment issues. The confirmation measurements were conducted over the full frequency band up to 270 GHz employing a backward wave oscillator (BWO) scalar network analyzer setup employing a BWO in the frequency range 190 GHz-270 GHz. PIC simulations were conducted for the realistic TWT output power performance analysis with incorporation of corner radius of 127 {mu}m, which is inevitably induced by nano-machining. Furthermore, the S{sub 21} value in both sections of the TWT structure was reduced to correspond to the measurements by using a degraded conductivity of 10% International Annealed Copper Standard. At 220 GHz, for an elliptic sheet electron beam of 20 kV and 0.25 A, the average output power of the tube was predicted

  2. Evaluation of Pt{sub 40}Pd{sub 60}/MWCNT electrocatalyst as ethylene glycol-tolerant oxygen reduction cathodes

    Energy Technology Data Exchange (ETDEWEB)

    Morales-Acosta, D.; Arriaga, L.G. [Centro de Investigacion y Desarrollo Tecnologico en Electroquimica, Parque Tecnologico Queretaro, Sanfandila, Pedro Escobedo, C.P. 76703 Queretaro (Mexico); Alvarez-Contreras, L. [Centro de Investigacion en Materiales Avanzados S.C., Complejo Industrial Chihuahua, C. P. 31109, Chihuahua, Chih. (Mexico); Luna, S. Fraire; Varela, F.J. Rodriguez [Cinvestav Unidad Saltillo, Carr. Saltillo-Monterrey Km. 13.5, Ramos Arizpe, Coahuila, C.P. 25900 (Mexico)

    2009-07-15

    Pt-Pd/MWCNT with Pt:Pd atomic ratio 40:60 and Pt/MWCNT electrocatalyst were synthesized and evaluated as oxygen reduction reaction (ORR) cathodes for Direct Ethylene Glycol Fuel Cells (DEGFC) applications. As reference, a commercial Pt/C material was also tested. We found that Pt-Pd/MWCNT has high tolerance capability to EG and higher selectivity for the ORR compared to the Pt-alone materials. As a result, the shift in onset potential for the ORR, E{sub onset}, at Pt-Pd/MWCNT was considerably smaller than the shift at Pt/MWCNT or Pt/C. The average particle size (from XRD) was 3.5 and 4 nm for Pt/MWCNT and Pt-Pd/MWCNT, respectively. A moderate degree of alloying was determined for the Pt-Pd material. An advantageous application of Pt-Pd electrocatalysts should be in DEGFCs. (author)

  3. Methanol electro-oxidation on Pt-Ru-P/C and Pt-Ru-P/MWCNT in acidic medium

    CSIR Research Space (South Africa)

    Modibedi, M

    2009-06-01

    Full Text Available Pt-Ru-P was prepared by the chemical reduction method using sodium hypophoshite as a reducing agent on Vulcan XC 72 and multi-walled carbon nano-tubes (MWCNTs). Sodium citrate was added as the stabilizer during electro-catalyst preparation...

  4. Microwave sinthesys and characterization of Pt and Pt-Rh-Sn electrocatalysts for ethanol oxidation

    Directory of Open Access Journals (Sweden)

    Jovanović Vladislava M.

    2011-01-01

    Full Text Available Carbon supported Pt and Pt-Rh-Sn catalysts were synthesized by microwave-polyol method in ethylene glycol solution and investigated for the ethanol electro-oxidation reaction. The catalysts were characterized in terms of structure, morphology and composition by employing XRD, STM and EDX techniques. STM analysis indicated rather uniform particles and particle size of below 2 nm for both catalysts. XRD analysis of the Pt/C catalyst revealed two phases, one with the main characteristic peaks of face centered cubic crystal structure (fcc of platinum and another related to graphite like structure of carbon support Vulcan XC-72R. However, in XRD pattern of the Pt-Rh-Sn/C catalyst diffraction peaks for Pt, Rh or Sn cannot be resolved, indicating an extremely low crystallinity. The small particle sizes and homogeneous size distributions of both catalysts should be attributed to the advantages of microwave assisted modified polyol process in ethylene glycol solution. Pt-Rh- Sn/C catalyst is highly active for the ethanol oxidation with the onset potential shifted for more than 150 mV to negative values and with currents nearly 5 times higher in comparison to Pt/C catalyst. The stability tests of the catalysts, as studied by the chronoamperometric experiments, reveal that the Pt-Rh-Sn/C catalyst is evidently less poisoned then Pt/C catalyst. The increased activity of Pt-Rh-Sn/C in comparison to Pt/C catalyst is most probably promoted by bifunctional mechanism and the electronic effect of alloyed metals.

  5. Highly durable graphene nanoplatelets supported Pt nanocatalysts for oxygen reduction

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Yuyan; Zhang, Sheng; Wang, Chongmin; Nie, Zimin; Liu, Jun; Lin, Yuehe [Pacific Northwest National Laboratory, Richland, WA 99352 (United States); Wang, Yong [Pacific Northwest National Laboratory, Richland, WA 99352 (United States); The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA 99164 (United States)

    2010-08-01

    We report graphene nanoplatelets (GNPs), which exhibit the advantages of both single-layer graphene and highly graphitic carbon, as a durable alternative support material for Pt nanoparticles for oxygen reduction in fuel cells. Pt nanoparticles are deposited on poly(diallyldimethylammonium chloride) (PDDA)-coated GNP, and characterized with transmission electron microscopy, X-ray diffraction, Raman spectra, and electrochemical tests. Pt/GNP exhibits greatly enhanced electrochemical durability (2-3 times that of Pt/CNT and commercial Etek Pt/C). These are attributed to the intrinsic high graphitization degree of GNP and the enhanced Pt-carbon interaction in Pt/GNP. If considering that GNP can be easily mass produced from graphite, GNP is a promising, low-cost, and durable electrocatalyst support for oxygen reduction in fuel cells. (author)

  6. Indoor test for the thermal performance evaluation of the DEC 8A large manifold sunmaster evacuated tube (liquid) solar collector

    Science.gov (United States)

    1981-01-01

    The Sunmaster DEC 8A Large Manifold solar collector using simulated conditions was evaluated. The collector provided 17.17 square feet of gross collector area. Test conditions, test requirements, an analysis of results, and tables of test data are reported.

  7. Test of the MarsSedEx Settling Tube Photometer during the 2nd Swiss Parabolic Flight Campaign

    Science.gov (United States)

    Kuhn, Nikolaus J.; Kuhn, Brigitte; Rüegg, Hans-Rudolf; Zimmermann, Lukas

    2017-04-01

    Gravity affects flow hydraulics and thus limits the application of simple models for sediment transport developed for Earth on Mars. The significance of the differences in sediment settling has been demonstrated for sand-sized particles by measuring settling velocities using video-imaging during parabolic flights. This approach does not work for finer particles because they cannot be distinguished individually on a video. Tracking of fine sediment clouds is also difficult using videos because changes in density are not captured. Photometers, on the other hand, are able to capture differences in turbidity and offer the potential to measure the settling behaviour of clouds of fine and differently-sized sediment particles. In this study, the feasibility of using a settling-tube photometer used for the rapid assessment of settling velocities developed by the University of Basel during a parabolic flight with reduced gravity is presented. In addition, the potential of the results generated in this Martian-analogue environment to support the identification sediments containing traces of life on Mars is discussed.

  8. Antithrombin Test

    Science.gov (United States)

    ... Homocysteine ; Lupus Anticoagulant ; Proteins C & S ; PT ; PT 20210 ; Factor V Leiden All content on Lab Tests Online has been ... such as a protein C or S deficiency , a factor V leiden mutation , or oral contraceptive use, then the person ...

  9. Experimental studies on effect of wire coiled coil matrix turbulators with and without bonding on the wall of the test section of concentric tube heat exchanger

    Directory of Open Access Journals (Sweden)

    Selvam S.

    2012-01-01

    Full Text Available This paper presents the effect of bonding and without bonding of wire coiled coil matrix turbulator on the heat transfer for a fully developed turbulent flow. Experiments are conducted by maintaining constant wall temperature. Tests are performed on 3 different wire coiled coil matrix turbulators of different pitches of 5, 10 and 15 mm without bonding of the turbulator. Three similar types of heat exchangers are fabricated and the wire coiled coil matrix turbulators with different pitches of 5, 10 and 15mm are inserted in the heat exchangers and bonding is done on the surface of the tube section. Results have indicated that the heat transfer rate enhances inversely with the pitch of the wire coiled coil matrix turbulator with bonding. With a pitch of 5 mm, the turbulators without bonding have resulted in almost 25.4% enhancement when compared with plain tube. On the other hand, for pitches of 10 mm and 15 mm the enhancement were 20.7% and 16.8%, respectively. The empirical correlations developed for turbulators with and without bonding results in ±6% deviation for Nusselt number and ±3% for friction factor. Similarly with a pitch of 5 mm, the turbulators with bonding have resulted in almost 42% enhancement. For pitches of 10mm and 15mm the enhancements were 34.7% and 25%, respectively.

  10. Chest tube insertion

    Science.gov (United States)

    ... tube insertion; Insertion of tube into chest; Tube thoracostomy; Pericardial drain ... Kirsch TD, Sax J. Tube thoracostomy. In: Roberts JR, ed. Roberts and ... . 6th ed. Philadelphia, PA: Elsevier Saunders; 2014:chap 10.

  11. Jejunostomy feeding tube

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/patientinstructions/000181.htm Jejunostomy feeding tube To use the sharing features on this ... vomiting Your child's stomach is bloated Alternate Names Feeding - jejunostomy tube; G-J tube; J-tube; Jejunum ...

  12. Impact of a pneumatic tube system transport on hemostasis parameters measurement: the experiment of Cochin universitary hospital (AP-HP, Paris, France).

    Science.gov (United States)

    Calmette, Leyla; Ibrahim, Firas; Gouin, Isabelle; Horellou, Marie-Hélène; Mazoyer, Élisabeth; Fontenay, Michaela; Flaujac, Claire

    2017-02-01

    Samples transported by pneumatic tube system are submitted to forces of acceleration and deceleration which can affect laboratory parameters. At Cochin hospital, majority of samples of hemostasis, except for platelets tests, are transported by pneumatic tube system. The objective of this study was to evaluate the impact of a pneumatic tube system (PTS) transport compared to hand-delivered transport on samples and to qualify Cochin hospital PTS according to requirements of standard ISO 15189. A bibliographical study was made and showed that pneumatic tube system particularly influences platelets tests. Four citrate tubes were collected in 5 healthy volunteers in the maternity: 2 tubes were transported by PTS and 2 others were hand-delivered to the laboratory. Five coagulation tests were analyzed: prothrombine time (PT), activated partial thromboplastin time (aPTT), factor (F) V, FVIII and platelet closure time with PFA-100TM collagen/epinephrine. For each volunteer, the results obtained by PTS and by hand-delivered transport were compared with formula usually used for biological analysis retake: 2.8 x standard deviation of reproductibility variation coefficient (SH GTA 01, COFRAC). This study did not show an impact of PTS on PT, aPTT, FV and FVIII. For PFA-100TM collagen/epinephrine, we noted an impact on 2/5 volunteers. These results, in agreement with the literature, led to the conclusion that Cochin hospital PTS is in compliance to transport samples for usual coagulation tests except platelet tests. This study allowed to issue French recommendations for PTS transport of hemostasis tubes qualification available on "Groupe français d'hémostase et thrombose" Web site.

  13. PT-symmetric strings

    Energy Technology Data Exchange (ETDEWEB)

    Amore, Paolo, E-mail: paolo.amore@gmail.com [Facultad de Ciencias, CUICBAS, Universidad de Colima, Bernal Díaz del Castillo 340, Colima, Colima (Mexico); Fernández, Francisco M., E-mail: fernande@quimica.unlp.edu.ar [INIFTA (UNLP, CCT La Plata-CONICET), División Química Teórica, Diag. 113 y 64 (S/N), Sucursal 4, Casilla de Correo 16, 1900 La Plata (Argentina); Garcia, Javier [INIFTA (UNLP, CCT La Plata-CONICET), División Química Teórica, Diag. 113 y 64 (S/N), Sucursal 4, Casilla de Correo 16, 1900 La Plata (Argentina); Gutierrez, German [Facultad de Ciencias, CUICBAS, Universidad de Colima, Bernal Díaz del Castillo 340, Colima, Colima (Mexico)

    2014-04-15

    We study both analytically and numerically the spectrum of inhomogeneous strings with PT-symmetric density. We discuss an exactly solvable model of PT-symmetric string which is isospectral to the uniform string; for more general strings, we calculate exactly the sum rules Z(p)≡∑{sub n=1}{sup ∞}1/E{sub n}{sup p}, with p=1,2,… and find explicit expressions which can be used to obtain bounds on the lowest eigenvalue. A detailed numerical calculation is carried out for two non-solvable models depending on a parameter, obtaining precise estimates of the critical values where pair of real eigenvalues become complex. -- Highlights: •PT-symmetric Hamiltonians exhibit real eigenvalues when PT symmetry is unbroken. •We study PT-symmetric strings with complex density. •They exhibit regions of unbroken PT symmetry. •We calculate the critical parameters at the boundaries of those regions. •There are exact real sum rules for some particular complex densities.

  14. Manually operated piston-driven shock tube

    OpenAIRE

    Reddy, KPJ; Sharath, N

    2013-01-01

    A simple hand-operated shock tube capable of producing Mach 2 shock waves is described. Performance of this miniature shock tube using compressed high pressure air created by a manually operated piston in the driver section of the shock tube as driver gas with air at 1 atm pressure as the test gas in the driven tube is presented. The performance of the shock tube is found to match well with the theoretically estimated values using normal shock relations. Applications of this shock tube named ...

  15. PT quantum mechanics.

    Science.gov (United States)

    Bender, Carl M; DeKieviet, Maarten; Klevansky, S P

    2013-04-28

    PT-symmetric quantum mechanics (PTQM) has become a hot area of research and investigation. Since its beginnings in 1998, there have been over 1000 published papers and more than 15 international conferences entirely devoted to this research topic. Originally, PTQM was studied at a highly mathematical level and the techniques of complex variables, asymptotics, differential equations and perturbation theory were used to understand the subtleties associated with the analytic continuation of eigenvalue problems. However, as experiments on PT-symmetric physical systems have been performed, a simple and beautiful physical picture has emerged, and a PT-symmetric system can be understood as one that has a balanced loss and gain. Furthermore, the PT phase transition can now be understood intuitively without resorting to sophisticated mathematics. Research on PTQM is following two different paths: at a fundamental level, physicists are attempting to understand the underlying mathematical structure of these theories with the long-range objective of applying the techniques of PTQM to understanding some of the outstanding problems in physics today, such as the nature of the Higgs particle, the properties of dark matter, the matter-antimatter asymmetry in the universe, neutrino oscillations and the cosmological constant; at an applied level, new kinds of PT-synthetic materials are being developed, and the PT phase transition is being observed in many physical contexts, such as lasers, optical wave guides, microwave cavities, superconducting wires and electronic circuits. The purpose of this Theme Issue is to acquaint the reader with the latest developments in PTQM. The articles in this volume are written in the style of mini-reviews and address diverse areas of the emerging and exciting new area of PT-symmetric quantum mechanics.

  16. Kinetics of the QuantiFERON-TB Gold In-Tube test during treatment of patients with sputum smear-positive tuberculosis in relation to initial TST result and severity of disease

    DEFF Research Database (Denmark)

    Idh, Jonna; Abate, Ebba; Westman, Anna

    2010-01-01

    The QuantiFERON-TB Gold In-Tube test (QFN) measures interferon-gamma production in response to Mycobacterium tuberculosis antigens. Our aim was to assess the kinetics of the QFN and initial tuberculin skin test (TST) result in relation to severity of disease in a tuberculosis (TB) endemic area...

  17. Electro-oxidation of methanol at the different carbon materials supported Pt nano-particles

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yu.; Zhang, Guojie; Zhou, Yiming; Tang, Yawen; Lu, Tianhong [The Laboratory of Electrochemistry, College of Chemistry and Material Science, Nanjing Normal University, 1 Wenyuan Road, Nanjing 210046 (China); Ma, Juan [Institute of Electrochemical Power Sources, Soochow University, Suzhou 215006 (China)

    2010-10-15

    Single-wall carbon nano-tubes (SWNTs), multi-wall carbon nano-tubes (MWNTs) and Vulcan XC-72 carbon (XC-72) are used as supporting carbon materials to prepare Pt/XC-72, Pt/SWNTs and Pt/MWNTs catalysts in tetrahydrofuran/water/ethanol mixture solution. Transmission electron microscope (TEM) and X-ray photoelectron spectroscopy (XPS) measurements demonstrate that the type of supporting carbon material affects significantly the morphology and the electronic structure of supported Pt nano-particles (NPs). Electrochemical measurements indicate that the Pt/SWNTs catalyst exhibited the highest current density, the lowest onset oxidation potential and the best stability for methanol electro-oxidation among the three samples, indicating SWNTs are an ideal anode catalyst supporting material for the practical application of direct methanol fuel cells. (author)

  18. A Comparison of Three-Dimensional Simulations of Traveling-Wave Tube Cold-Test Characteristics Using CST MICROWAVE STUDIO and MAFIA

    Science.gov (United States)

    Chevalier, C. T.; Herrmann, K. A.; Kory, C. L.; Wilson, J. D.; Cross, A. W.; Williams, W. D. (Technical Monitor)

    2001-01-01

    Previously, it was shown that MAFIA (solutions of Maxwell's equations by the Finite Integration Algorithm), a three-dimensional simulation code, can be used to produce accurate cold-test characteristics including frequency-phase dispersion, interaction impedance, and attenuation for traveling-wave tube (TWT) slow-wave structures. In an effort to improve user-friendliness and simulation time, a model was developed to compute the cold-test parameters using the electromagnetic field simulation software package CST MICROWAVE STUDIO (MWS). Cold-test parameters were calculated for several slow-wave circuits including a ferruled coupled-cavity, a folded waveguide, and a novel finned-ladder circuit using both MWS and MAFIA. Comparisons indicate that MWS provides more accurate cold-test data with significantly reduced simulation times. Both MAFIA and MWS are based on the finite integration (FI) method; however, MWS has several advantages over MAFIA. First, it has a Windows based interface for PC operation, making it very user-friendly, whereas MAFIA is UNIX based. MWS uses a new Perfect Boundary Approximation (PBA), which increases the accuracy of the simulations by avoiding stair step approximations associated with MAFIA's representation of structures. Finally, MWS includes a Visual Basic for Applications (VBA) compatible macro language that enables the simulation process to be automated and allows for the optimization of user-defined goal functions, such as interaction impedance.

  19. photomultiplier tube

    CERN Multimedia

    photomultiplier tubes. A device to convert light into an electric signal (the name is often abbreviated to PM). Photomultipliers are used in all detectors based on scintillating material (i.e. based on large numbers of fibres which produce scintillation light at the passage of a charged particle). A photomultiplier consists of 3 main parts: firstly, a photocathode where photons are converted into electrons by the photoelectric effect; secondly, a multiplier chain consisting of a serie of dynodes which multiply the number of electron; finally, an anode, which collects the resulting current.

  20. photomultiplier tubes

    CERN Multimedia

    photomultiplier tubes. A device to convert light into an electric signal (the name is often abbreviated to PM). Photomultipliers are used in all detectors based on scintillating material (i.e. based on large numbers of fibres which produce scintillation light at the passage of a charged particle). A photomultiplier consists of 3 main parts: firstly, a photocathode where photons are converted into electrons by the photoelectric effect; secondly, a multiplier chain consisting of a serie of dynodes which multiply the number of electron; finally, an anode, which collects the resulting current.

  1. Eddy-current tests on operational evaluation of steam generator tubes in nuclear power plants; Ensaios de Eddy-current na avaliacao do estado operacional de tubos de geradores de vapor de centrais nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, Luiz Antonio Negro Martin [Faculdade de Engenharia Industrial (FEI), Sao Paulo, SP (Brazil). Dept. de Energetica]. E-mail: luizlope@cci.fei.br; Ting, Daniel Kao Sun [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil). Dept. Engenharia de Reatores]. E-mail: dksting@net.ipen.br

    2000-07-01

    This paper presents a worldwide research on the technical and economical impacts due to failure in tube bundles of nuclear power plant steam generators. An Eddy current non destructive test using Foucault currents for the inspection and failure detection on the tubes, and also the main type of defects. The paper also presents the signals generated by a Zetec MIZ-40 test equipment. This paper also presents a brief description of an automatic system for data analysis which is under development by using a fuzzy logic and artificial intelligence.

  2. Data bank on hydrodynamics, thermal tests and tube temperature regimes of PGV-4 and PVG-1000 natural steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Ageev, A.G.; Vasileva, R.V.; Nigmatulin, B.I.; Titov, V.F.; Tarankov, G.N. [EREC Electrogorsk Research and Engineering Centre of Nuclear Plants Safety, Moscow (Russian Federation)

    1995-12-31

    The data bank was prepared by EREC, OKB `Hydropress` using results of static and dynamic tests of PGV-4 and PGV- 1000 natural steam generators cared out at Kolskaya, Novo-Voronezhskaya, Ugno-Ukrainskaya, Balakov-skaya and Hmelnitskaya NPP within period of 1974-1993. It is destined for making calculation codes verification. (authors).

  3. Use of vacuum tubes in test instrumentation for measuring characteristics of fast high-voltage semiconductor devices

    Science.gov (United States)

    Berning, D.

    1981-01-01

    Circuits are described that permit measurement of fast events occurring in power semiconductors. These circuits were developed for the dynamic characterization of transistors used in inductive-load switching applications. Fast voltage clamping using vacuum diodes is discussed, and reference is made to a unique circuit that was built for performing nondestructive, reverse-bias, second-breakdown tests on transistors.

  4. Measurement of impulse peak insertion loss from two acoustic test fixtures and four hearing protector conditions with an acoustic shock tube

    Directory of Open Access Journals (Sweden)

    William J Murphy

    2015-01-01

    Full Text Available Impulse peak insertion loss (IPIL was studied with two acoustic test fixtures and four hearing protector conditions at the E-A-RCAL Laboratory. IPIL is the difference between the maximum estimated pressure for the open-ear condition and the maximum pressure measured when a hearing protector is placed on an acoustic test fixture (ATF. Two models of an ATF manufactured by the French-German Research Institute of Saint-Louis (ISL were evaluated with high-level acoustic impulses created by an acoustic shock tube at levels of 134 decibels (dB, 150 dB, and 168 dB. The fixtures were identical except that the E-A-RCAL ISL fixture had ear canals that were 3 mm longer than the National Institute for Occupational Safety and Health (NIOSH ISL fixture. Four hearing protection conditions were tested: Combat Arms earplug with the valve open, ETYPlugs ® earplug, TacticalPro headset, and a dual-protector ETYPlugs earplug with TacticalPro earmuff. The IPILs measured for the E-A-RCAL fixture were 1.4 dB greater than the National Institute for Occupational Safety and Health (NIOSH ISL ATF. For the E-A-RCAL ISL ATF, the left ear IPIL was 2.0 dB greater than the right ear IPIL. For the NIOSH ATF, the right ear IPIL was 0.3 dB greater than the left ear IPIL.

  5. Evaluation of the Widal tube agglutination test for the diagnosis of typhoid fever among children admitted to a rural hdospital in Tanzania and a comparison with previous studies

    Directory of Open Access Journals (Sweden)

    Malahiyo Rajabu

    2010-06-01

    Full Text Available Abstract Background The diagnosis of typhoid fever is confirmed by culture of Salmonella enterica serotype Typhi (S. typhi. However, a more rapid, simpler, and cheaper diagnostic method would be very useful especially in developing countries. The Widal test is widely used in Africa but little information exists about its reliability. Methods We assessed the performance of the Widal tube agglutination test among febrile hospitalized Tanzanian children. We calculated the sensitivity, specificity, positive predictive value (PPV, and negative predictive value (NPV of various anti-TH and -TO titers using culture-confirmed typhoid fever cases as the "true positives" and all other febrile children with blood culture negative for S. typhi as the "true negatives." Results We found that 16 (1% of 1,680 children had culture-proven typhoid fever. A single anti-TH titer of 1:80 and higher was the optimal indicator of typhoid fever. This had a sensitivity of 75%, specificity of 98%, NPV of 100%, but PPV was only 26%. We compared our main findings with those from previous studies. Conclusion Among febrile hospitalized Tanzanian children with a low prevalence of typhoid fever, a Widal titer of ≥ 1:80 performed well in terms of sensitivity, specificity, and NPV. However a test with improved PPV that is similarly easy to apply and cost-efficient is desirable.

  6. Comparison of Rose Bengal Plate Agglutination, Standard tube agglutination and Indirect ELISA tests for detection of Brucella antibodies in Cows and Buffaloes

    Directory of Open Access Journals (Sweden)

    S. N. Ghodasara

    2010-04-01

    Full Text Available A total of 180 serum samples (107 cows, 73 buffaloes from cases of abortion and various reproductive disorders were collected for detection of Brucella antibody by Rose Bengal Plate Agglutination Test (RBPT, Serum Tube Agglutination Test (STAT and indirect- ELISA (i-ELISA. The overall prevalence of brucellosis by RBPT, STAT and i-ELISA were 11.21%, 16.00% and 24.30% in cows 9.59%, 12.33% and 26.03% in buffaloes respectively. Overall seroprevalence of Brucellosis in cases of abortion, R.O.P. by RBPT, STAT and i-ELISA were 11.32%, 16.04% and 32.08% respectively. When three serological tests were compared, seropositivity was found highest by i-ELISA (25%, followed by STAT (14.45% and RBPT (10.56%. The results shows higher prevalence of brucellosis in cases of abortion and R.O.P., while at lower level from various reproductive disorders as detected serologically indicating endemicity of the infection in villages around Anand city, Gujarat. [Vet. World 2010; 3(2.000: 61-64

  7. Measurement of impulse peak insertion loss from two acoustic test fixtures and four hearing protector conditions with an acoustic shock tube.

    Science.gov (United States)

    Murphy, William J; Fackler, Cameron J; Berger, Elliott H; Shaw, Peter B; Stergar, Mike

    2015-01-01

    Impulse peak insertion loss (IPIL) was studied with two acoustic test fixtures and four hearing protector conditions at the E-A-RCAL Laboratory. IPIL is the difference between the maximum estimated pressure for the open-ear condition and the maximum pressure measured when a hearing protector is placed on an acoustic test fixture (ATF). Two models of an ATF manufactured by the French-German Research Institute of Saint-Louis (ISL) were evaluated with high-level acoustic impulses created by an acoustic shock tube at levels of 134 decibels (dB), 150 dB, and 168 dB. The fixtures were identical except that the E-A-RCAL ISL fixture had ear canals that were 3 mm longer than the National Institute for Occupational Safety and Health (NIOSH) ISL fixture. Four hearing protection conditions were tested: Combat Arms earplug with the valve open, ETYPlugs ® earplug, TacticalPro headset, and a dual-protector ETYPlugs earplug with TacticalPro earmuff. The IPILs measured for the E-A-RCAL fixture were 1.4 dB greater than the National Institute for Occupational Safety and Health (NIOSH) ISL ATF. For the E-A-RCAL ISL ATF, the left ear IPIL was 2.0 dB greater than the right ear IPIL. For the NIOSH ATF, the right ear IPIL was 0.3 dB greater than the left ear IPIL.

  8. Pre-analytical effects of pneumatic tube system transport on routine haematology and coagulation tests, global coagulation assays and platelet function assays.

    Science.gov (United States)

    Le Quellec, Sandra; Paris, Mickaël; Nougier, Christophe; Sobas, Frédéric; Rugeri, Lucia; Girard, Sandrine; Bordet, Jean-Claude; Négrier, Claude; Dargaud, Yesim

    2017-05-01

    Pneumatic tube system (PTS) in hospitals is commonly used for the transport of blood samples to clinical laboratories, as it is rapid and cost-effective. The aim was to compare the effects on haematology samples of a newly acquired ~2km-long PTS that links 2 hospitals with usual transport (non-pneumatic tube system, NPTS). Complete blood cell count, routine coagulation assays, platelet function tests (PFT) with light-transmission aggregometry and global coagulation assays including ROTEM® and thrombin generation assay (TGA) were performed on blood samples from 30 healthy volunteers and 9 healthy volunteers who agreed to take aspirin prior to blood sampling. The turnaround time was reduced by 31% (p<0.001) with the use of PTS. No statistically significant difference was observed for most routine haematology assays including PFT, and ROTEM® analysis. A statistically significant, but not clinically relevant, shortening of the APTT after sample transport by PTS was found (mean±SD: 30s±1.8 vs. 29.5s±2.1 for NPTS). D-dimer levels were 7.4% higher after transport through PTS but were not discordant. A statistically significant increase of thrombin generation was found in both platelet poor- and platelet rich- plasma samples after PTS transport compared to NPTS transport. PTS is suitable for the transport of samples prior to routine haematology assays including PFT, but should not be used for samples intended for thrombin generation measurement. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Surface Chemistry of Aromatic Reactants on Pt- and Mo-Modified Pt Catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, Allison M.; Mark, Lesli; Rasmussen, Mathew J.; Hensley, Jesse E.; Medlin, J. Will

    2016-11-01

    Supported catalysts containing an oxophilic metal such as Mo and a noble metal such as Pt have shown promising activity and selectivity for deoxygenation of biomass-derived compounds. Here, we report that PtMo catalysts also promote hydrogenolysis of the model compound benzyl alcohol, while decarbonylation is most prevalent over unmodified Pt. A combination of single crystal surface science studies, density functional theory (DFT) calculations, and vapor phase upgrading experiments using supported catalysts was carried out to better understand the mechanism by which Mo promotes deoxygenation. Molybdenum was deposited in submonolayer quantities on a Pt(111) surface and reduced at high temperature. Temperature-programmed desorption (TPD) experiments using benzyl alcohol as a reactant showed greatly enhanced yields of the deoxygenation product toluene at moderate Mo coverages. To understand how the interaction of the aromatic group with the surface influenced this reactivity, we investigated the adsorption of toluene as a probe molecule. We found that the addition of Mo to Pt(111) resulted in a significant decrease in toluene decomposition. DFT calculations indicated that this decrease was consistent with decreased aromatic adsorption strengths that accompany incorporation of Mo into the Pt subsurface. The weaker aromatic-surface interaction on Pt/Mo surfaces led to a tilted adsorption geometry for benzyl alcohol, which presumably promotes hydrogenolysis to produce toluene instead of decarbonylation to produce benzene and CO. Alumina-supported Pt and PtMo catalysts were also tested for benzyl alcohol deoxygenation. PtMo catalysts had a higher rate of toluene production and lower rates of benzene and benzaldehyde production. Additionally, when benzaldehyde was used as the reactant to measure decarbonylation activity the mass-normalized rate of benzene production was 2.5 times higher on Pt than PtMo. Overall, the results of TPD, DFT, and supported catalyst experiments

  10. In-situ tube burst testing and high-temperature deformation behavior of candidate materials for accident tolerant fuel cladding

    Science.gov (United States)

    Gussev, M. N.; Byun, T. S.; Yamamoto, Y.; Maloy, S. A.; Terrani, K. A.

    2015-11-01

    One of the most essential properties of accident tolerant fuel (ATF) for maintaining structural integrity during a loss-of-coolant accident (LOCA) is high resistance of the cladding to plastic deformation and burst failure, since the deformation and burst behavior governs the cooling efficiency of flow channels and the process of fission product release. To simulate and evaluate the deformation and burst process of thin-walled cladding, an in-situ testing and evaluation method has been developed on the basis of visual imaging and image analysis techniques. The method uses a specialized optics system consisting of a high-resolution video camera, a light filtering unit, and monochromatic light sources. The in-situ testing is performed using a 50 mm long pressurized thin-walled tubular specimen set in a programmable furnace. As the first application, ten (10) candidate cladding materials for ATF, i.e., five FeCrAl alloys and five nanostructured steels, were tested using the newly developed method, and the time-dependent images were analyzed to produce detailed deformation and burst data such as true hoop stress, strain (creep) rate, and failure stress. Relatively soft FeCrAl alloys deformed and burst below 800 °C, while negligible strain rates were measured for higher strength alloys.

  11. Preparation and characterization of Pt-CeO2/C and Pt-TiO2/C electrocatalysts with improved electrocatalytic activity for methanol oxidation

    Science.gov (United States)

    Hameed, R. M. Abdel; Amin, R. S.; El-Khatib, K. M.; Fetohi, Amani E.

    2016-03-01

    Pt-TiO2/C and Pt-CeO2/C electrocatalysts were synthesized by solid state reaction of TiO2/C and CeO2/C powders using intermittent microwave heating, followed by chemical reduction of platinum ions using mixed reducing agents of ethylene glycol and sodium borohydride. The crystal structure, surface morphology and chemical composition of prepared electrocatalysts were investigated using X-ray diffraction (XRD), transmission electron microscopy (TEM) and energy dispersive X-ray analysis (EDX). The phase angle values of different Pt diffraction planes in Pt-TiO2/C and Pt-CeO2/C were shifted in the positive direction relative to those in Pt/C. Pt particles with diameter values of 3.06 and 2.78 nm were formed in Pt-TiO2/C and Pt-CeO2/C, respectively. The electrochemical performance of prepared electrocatalysts was examined using cyclic voltammetry, chronoamperometry and electrochemical impedance spectroscopy. Pt-CeO2/C showed an enhanced oxidation current density when compared to Pt/C. Long time oxidation test at Pt-TiO2/C and Pt-CeO2/C revealed their improved stability. Lower charge transfer resistance values were estimated at Pt-metal oxide/C electrocatalysts.

  12. A tube-in-tube thermophotovoltaic generator

    Energy Technology Data Exchange (ETDEWEB)

    Ashcroft, J.; Campbell, B.; Depoy, D.

    1996-12-31

    A thermophotovoltaic device includes at least one thermal radiator tube, a cooling tube concentrically disposed within each thermal radiator tube and an array of thermophotovoltaic cells disposed on the exterior surface of the cooling tube. A shell having a first end and a second end surrounds the thermal radiator tube. Inner and outer tubesheets, each having an aperture corresponding to each cooling tube, are located at each end of the shell. The thermal radiator tube extends within the shell between the inner tubesheets. The cooling tube extends within the shell through the corresponding apertures of the two inner tubesheets to the corresponding apertures of the two outer tubesheets. A plurality of the thermal radiator tubes can be arranged in a staggered or an in-line configuration within the shell.

  13. Synthesis of Pt and Pt-Fe nanoparticles supported on MWCNTs used as electrocatalysts in the methanol oxidation reaction

    Institute of Scientific and Technical Information of China (English)

    J.R.Rodriguez; R.M.F´elix; E.A.Reynoso; Y.Gochi-Ponce; Y.Verde Gómez; S.Fuentes Moyado; G.Alonso-N ´uñez

    2014-01-01

    This work reports a feasible synthesis of highly-dispersed Pt and Pt-Fe nanoparticles supported on multiwall carbon nanotubes (MWCNTs) without Fe and multiwall carbon nanotubes with iron (MWCNTs-Fe) which applied as electrocatalysts for methanol electrooxidation. A Pt coordination complex salt was synthesized in an aqueous solution and it was used as precursor to prepare Pt/MWCNTs, Pt/MWCNTs-Fe, and Pt-Fe/MWCNTs using FeCl2·4H2O as iron source which were named S1, S2 and S3, respectively. The coordination complex of platinum (TOA)2PtCl6 was obtained by the chemical reaction between (NH4)2PtCl6 with tetraoctylammonium bromide (TOAB) and it was characterized by FT-IR and TGA. The materials were characterized by Raman spectroscopy, SEM, EDS, XRD, TEM and TGA. The electrocatalytic activity of Pt-based supported on MWCNTs in the methanol oxidation was investigated by cyclic voltammetry (CV) and chronoamperometry (CA). Pt-Fe/MWCNTs electrocatalysts showed the highest electrocatalytic activity and stability among the tested electrocatalysts due to that the addition of”Fe”promotes the OH species adsorption on the electrocatalyst surface at low potentials, thus, enhancing the activity toward the methanol oxidation reaction (MOR).

  14. Pt Ru/C electrocatalysts prepared using electron beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Dionisio F.; Oliveira Neto, Almir; Pino, Eddy S.; Brandalise, Michele; Linardi, Marcelo; Spinace, Estevam V. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mails: dfsilva@ipen.br; espinace@ipen.br

    2007-07-01

    Pt Ru/C electrocatalysts (carbon-supported Pt Ru nanoparticles) were prepared submitting water/ethylene glycol solutions containing Pt(IV) and Ru(III) ions and the carbon support to electron beam irradiation. The water/ethylene glycol ratio (v/v) was evaluated as synthesis parameters. The Pt Ru/C electrocatalysts were prepared with a nominal Pt:Ru atomic ratio of 50:50 and were characterized by energy dispersive X-ray analysis (EDX) and X-ray diffraction (XRD) and tested for methanol electro-oxidation using cyclic voltammetry and chronoamperometry. The obtained Pt Ru/C electrocatalysts showed the typical fcc structure of platinum-ruthenium alloys and the electrocatalytic activity depends on the water/ethylene glycol ratio used in the preparation.

  15. Comparative study of three screening tests, two microbiological tube tests, and a multi-sulphonamide ELISA kit for the detection of antimicrobial and sulphonamide residues in eggs.

    Science.gov (United States)

    Gaudin, V; Hedou, C; Rault, A; Sanders, P; Verdon, E

    2009-04-01

    The screening of antimicrobial residues in eggs is an especially important subject. Three different commercial kits for the screening of sulphonamides and other antimicrobials in eggs were validated in accordance with Decision 2002/657/EC: one enzyme-linked immunoabsorbant assay (ELISA) kit multi-sulphonamides (from RAISIO Diagnostics) and two microbiological tests (a Premi test from DSM and an Explorer kit from Zeu-Inmunotec). The false-positive rates were lower than 2% for all kits. The detection capabilities (CCbeta) have to be as low as possible for banned substances and lower than the maximum residue limit (MRL) when MRLs have been set. The sensitivity of the Premi test was better than that of the Explorer test, probably because of the dilution of the eggs before the Explorer test was used. The CCbeta values towards most of the tested sulphonamides were satisfactory with the Premi test (sulphonamides in eggs with the Premi test confirmed these results. The detection capabilities of tetracycline and doxycycline were at the level of the MRL or twice the MRL maximum. The detection capabilities for chlortetracycline and oxytetracycline were higher (four to six times the MRL). The detection capabilities for amoxicillin, neomycin, tylosin and erythromycin were lower than their respective MRLs. Detection capabilities for sulphonamides were much lower for the ELISA kit than for microbiological tests. The ELISA kit could be recommended for the targeted screening of sulphonamides in eggs. On the other hand, the Explorer and Premi tests could be used as wide screening tests allowing the detection of most of the antimicrobial families.

  16. PT symmetry and supersymmetry

    CERN Document Server

    Znojil, M

    2002-01-01

    A re-formulated, non-Hermitian version of the Witten's supersymmetric quantum mechanics is presented. Its use of pseudo-Hermitian (so called PT symmetric) Hamiltonians is reviewed and illustrated via several forms of an innovated supersymmetric partnership between strongly singular ("spiked") harmonic oscillators.

  17. Pt-Ni and Pt-Co Catalyst Synthesis Route for Fuel Cell Applications

    Science.gov (United States)

    Firdosy, Samad A.; Ravi, Vilupanur A.; Valdez, Thomas I.; Kisor, Adam; Narayan, Sri R.

    2013-01-01

    Oxygen reduction reactions (ORRs) at the cathode are the rate-limiting step in fuel cell performance. The ORR is 100 times slower than the corresponding hydrogen oxidation at the anode. Speeding up the reaction at the cathode will improve fuel cell efficiency. The cathode material is generally Pt powder painted onto a substrate (e.g., graphite paper). Recent efforts in the fuel cell area have focused on replacing Pt with Pt-X alloys (where X = Co, Ni, Zr, etc.) in order to (a) reduce cost, and (b) increase ORR rates. One of these strategies is to increase ORR rates by reducing the powder size, which would result in an increase in the surface area, thereby facilitating faster reaction rates. In this work, a process has been developed that creates Pt-Ni or Pt-Co alloys that are finely divided (on the nano scale) and provide equivalent performance at lower Pt loadings. Lower Pt loadings will translate to lower cost. Precursor salts of the metals are dissolved in water and mixed. Next, the salt mixtures are dried on a hot plate. Finally, the dried salt mixture is heattreated in a furnace under flowing reducing gas. The catalyst powder is then used to fabricate a membrane electrode assembly (MEA) for electrochemical performance testing. The Pt- Co catalyst-based MEA showed comparable performance to an MEA fabri cated using a standard Pt black fuel cell catalyst. The main objective of this program has been to increase the overall efficiencies of fuel cell systems to support power for manned lunar bases. This work may also have an impact on terrestrial programs, possibly to support the effort to develop a carbon-free energy source. This catalyst can be used to fabricate high-efficiency fuel cell units that can be used in space as regenerative fuel cell systems, and terrestrially as primary fuel cells. Terrestrially, this technology will become increasingly important when transition to a hydrogen economy occurs.

  18. Development of an instrument for wall thickness measurement for stability testing of suspended API tubes in mineshafts; Entwicklung eines Wanddicken-Messgeraetes zum Pruefen der Standsicherheit von im Schacht freihaengenden API-Rohrleitungen

    Energy Technology Data Exchange (ETDEWEB)

    Hufendiek, H.W.; Gronau, O. [Deutsche Montan Technologie GmbH, Bochum (Germany). Car Synergies Division

    2001-07-01

    As suspended tubes in mineshafts are getting more common, corrosion and wear will reduce wall thickness of tubes and tube joints and affect their operating characteristics. In the context of a R + D project funded by the state of Nordrhein-Westfalen from 1992 through 1994, the TesTec Department carried out measurements on suspended tubes in coal mines. It was found that suspended tubes will still function without problems with a 25% wall thickness reduction. So far, there was no satisfactory method of measuring the real wall thickness of the tube joints. In the case of the tubes themselves, there are several options, e.g. US point measurements from outside, indirect measurements using mechanical probes, and ultrasonic measurements of fluids from inside. The TesTec Department proved that magnetic induction sensors commonly used in steel cable testing can be used for measuring corrosion damage and cross section reductions. Preliminary tests were carried out on tubes and plates for this purpose. The TesTec instrument will be modified into a test pig for monitoring suspended tubes in mineshafts. [German] Rohrleitungen in Schaechten des Ruhrbergbaus werden immer haeufiger als freihaengende Leitungen ausgefuehrt. Korrosion und Verschleiss fuehren zu Minderungen der Wandstaerken in den Rohrleitungen und deren Muffenverbindungen und damit zu einer Verminderung der Tragfaehigkeit. Untersuchungen des Geschaeftsbereiches TesTec im Rahmen eines vom Land Nordrhein-Westfalen bezuschussten Untersuchungs- und Entwicklungsvorhabens in der Zeit von 1992 bis 1994 haben gezeigt, dass unter Beruecksichtigung statischer und dynamischer Belastungen des Rohrleitungssystems eine bis zu 25%-ige Querschnittsminderung noch einen sicheren Betrieb gewaehrleistet. Fuer die Bestimmung des tatsaechlichen Restquerschnitts, insbesondere im Muffenbereich, gibt es bisher keine zufriedenstellende Messmethode. Die Erfassung der tatsaechlichen Wanddicke der Rohre is von aussen z.B. durch punktuelle US

  19. Design Features of the Separate Effect Test Facility for a Forced-Draft Sodium-to-Air Heat Exchanger (FHX) with Helical Finned Tubes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyungmo; Eoh, Jaehyuk; Ko, Yung Joo; Cho, Youngil; Kim, Jong-Man; Lee, Hyeong-Yeon; Jeong, Ji-Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    A sodium-cooled fast reactor (SFR) is one of the most promising options to pursue these purposes, and the Korea Atomic Energy Research Institute (KAERI) is currently developing a PGSFR (Prototype Gen-IV Sodium-cooled Fast Reactor) with a pool-type reactor vessel. Among the many components in an SFR, a decay heat removal system (DHRS) is very important for a safety of nuclear power plants. The PGSFR adopted two different kinds of DHRS: an active and passive DHRS, and the decay heat from the primary sodium pool is moved to the two kinds of sodium-to-air heat exchangers as ultimate heat sinks through sodium-to-sodium decay heat exchangers (DHX). To verify the cooling performances and thermal-hydraulic characteristics of this type of heat exchanger, a separate effect sodium test facility named as SELFA (Sodium thermal-hydraulic Experiment Loop for Finned-tube sodium-to-Air heat exchanger) is being developed. The purposes of SELFA are verification and validation of the design code for FHX. For this, scales and configurations of SELFA are carefully defined as similarity with the FHX in the PGSFR. In this paper, we propose the key design features of SELFA including the model FHX (M-FHX) unit. To verify and validate a design code of the FHX in PGSFR, a separate effect test facility called as SELFA has being developed in KAERI.

  20. Diagnosis of latent tuberculosis infection before initiation of anti-tumor necrosis factor therapy using both tuberculin skin test and QuantiFERON-TB Gold In Tube assay.

    Science.gov (United States)

    Kim, Ho-Cheol; Jo, Kyung-Wook; Jung, Young Ju; Yoo, Bin; Lee, Chang-Keun; Kim, Yong-Gil; Yang, Suk-Kyun; Byeon, Jeong-Sik; Kim, Kyung-Jo; Ye, Byong Duk; Shim, Tae Sun

    2014-11-01

    Reactivation of latent tuberculosis infection (LTBI) is an important complication in patients treated with tumor necrosis factor-alpha (TNF-α) blocking agents. However, the best method for LTBI detection before initiation of anti-TNF therapy remains to be determined. From January 2010 to August 2013, anti-TNF therapy was initiated in 426 patients with immune-mediated inflammatory diseases (IMIDs). Tuberculin skin test (TST) and Quantiferon-TB Gold In Tube (QFT-GIT) assay were performed before starting anti-TNF treatment. LTBI was defined as a positive TST (induration ≥ 10 mm) or as a positive QFT-GIT result. Patients were followed up until December 2013. The positive TST and QFT-GIT rates were 22.3% (95/426) and 16.0% (68/426), respectively, yielding a total of 27.0% (115/426) of positive LTBI results. LTBI treatment was initiated in 25.1% (107/426) and was completed in 100% (107/107) of patients. During a median 294 days of follow-up, active TB occurred in 1.4% (6/426) of the patients with negative TST and QFT-GIT results at baseline. The either test positive strategy, using both TST and QFT-GIT assay, is acceptable for LTBI screening before commencing anti-TNF therapy in patients with IMIDs.

  1. 管道远场涡流无损检测技术综述%Remote Field Eddy Current Non-Destructive Testing for Pipes and Tubes

    Institute of Scientific and Technical Information of China (English)

    徐小杰

    2015-01-01

    Remote Field Eddy Current ( RFEC) is an important branch cut of eddy current nondestructive testing ( NDT) technique, and draws more and more attention in the testing and repairing of pipes and tubes. The origin and development history of RFEC technique was described. The research status and hot-spot issues of RFFC technique both inland and overseas were sum-marized and analyzed. The future development direction of RFEC technique was discussed with detail, from the aspects such as axial crack detection ability improvement,mounting plate influence in use and so on.%远场涡流作为涡流无损检测技术的一个重要分支,目前在各个行业的管道日常维护和安全保障中发挥着重要的作用。文中首先详细叙述了远场涡流无损检测技术的发展历史;对目前国内外远场涡流应用的研究现状和研究热点问题进行了总结和论述;从进一步提高轴向裂纹检测能力,解决使用中支撑板影响问题等方面,探讨了远场涡流无损检测技术的应用发展方向。

  2. Effect of tube-support interaction on the dynamic responses of heat exchanger tubes. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Y.S.; Jendrzejczyk, J.A.; Wambsganss, M.W.

    1977-01-01

    Operating heat exchangers have experienced tube damages due to excessive flow-induced vibration. The relatively small inherent tube-to-baffle hole clearances associated with manufacturing tolerances in heat exchangers affect the tube vibrational characteristics. In attempting a theoretical analysis, questions arise as to the effects of tube-baffle impacting on dynamic responses. Experiments were performed to determine the effects of tube-baffle impacting in vertical/horizontal tube orientation, and in air/water medium on the vibrational characteristics (resonant frequencies, mode shapes, and damping) and displacement response amplitudes of a seven-span tube model. The tube and support conditions were prototypic, and overall length approximately one-third that of a straight tube segment of the steam generator designed for the CRBR. The test results were compared with the analytical results based on the multispan beam with ''knife-edge'' supports.

  3. Fin-tube solar collectors

    Science.gov (United States)

    1980-01-01

    Report presents test procedures and results of thermal-performance evaluation of seven commercial fin tube (liquid) solar collector-absorber plates. Tests were conducted indoors at Marshall Space Flight Center Solar simulator. Results are graphically shown along with supporting test data and summary, indicating efficiency as function of collector inlet temperature.

  4. Evaluation of the QuantiFERON?-TB Gold In-Tube assay and tuberculin skin test for the diagnosis of Mycobacterium tuberculosis infection in northeastern Thailand.

    Science.gov (United States)

    Reechaipichitkul, Wipa; Pimrin, Wilailuk; Bourpoern, Janpen; Prompinij, Supapim; Faksri, Kiatichai

    2015-09-01

    The diagnosis of latent Mycobacterium tuberculosis infection (LTBI) is currently based on the immunological response of T-cells to M. tuberculosis (MTB) antigens. However, the QuantiFERON®-TB Gold In-Tube assay (QFT) has not yet been evaluated in the Thai adult population. To evaluate the diagnostic performance and determine predictors of discordant results between the QFT and tuberculin skin test (TST). Active tuberculosis (ATB) patients (n=54), close contacts (CCs) living in the same household as a TB patient (n=100) and healthy controls (HCs) (n=60) were interviewed and underwent the QFT and TST at Srinagarind Hospital in Thailand. Various cut-off values for the QFT (0.25-0.35 IU/mL) and TST (5-15 mm) were applied. The maximum agreement rate between the tests was 71.5% (κ=0.41) with cut-offs of 0.35 IU/mL and 10 mm or 0.25 IU/mL and 10 mm. Based on standard cut-off values (0.35 IU/mL and 10 mm) and using ATB patients and HCs as positive and negative controls, the TST was more sensitive than the QFT (87.0% vs. 66.7%, respectively), whereas the QFT was more specific than the TST (83.3% vs. 70.0%, respectively). Being underweight (OR 3.86, 95%CI 1.3-11.48) or overweight (OR 5.9, 95%CI 1.24-28.16) was significantly associated with TST+/QFT- results. Diabetes (OR 32.56, 95%CI 1.73-613.49) and poor or fair nutrition (OR 7.4, 95%CI 1.23-44.57) were significantly associated with TST-/QFT+ results. The TST should be used as a screening test based on its higher sensitivity, whereas the QFT should be used as a confirmatory test because of its higher specificity.

  5. Selective oxidation of methylamine over zirconia supported Pt-Ru, Pt and Ru catalysts

    Institute of Scientific and Technical Information of China (English)

    Aiying Song; Gongxuan Lu

    2015-01-01

    Pt–Ru, Pt and Ru catalysts supported on zirconia were prepared by impregnation method and were tested in se-lective oxidation of methylamine (MA) in aqueous media. Among three catalysts, Ru/ZrO2 was more active than Pt/ZrO2 while Pt–Ru/ZrO2 demonstrated the best catalytic activity due to the fact that Pt addition efficiently pro-moted the dispersion of active species in bimetallic catalyst. Therefore, the~100%TOC conversion and N2 selec-tivity were achieved over Pt–Ru/ZrO2, Pt/ZrO2 and Ru/ZrO2 catalysts at 190, 220 and 250 °C, respectively.

  6. A BOSE-EINSTEIN CONDENSATE WITH PT-SYMMETRIC DOUBLE-DELTA FUNCTION LOSS AND GAIN IN A HARMONIC TRAP: A TEST OF RIGOROUS ESTIMATES

    Directory of Open Access Journals (Sweden)

    Daniel Haag

    2014-04-01

    Full Text Available We consider the linear and nonlinear Schrödinger equation for a Bose-Einstein condensate in a harmonic trap with PT-symmetric double-delta function loss and gain terms. We verify that the conditions for the applicability of a recent proposition by Mityagin and Siegl on singular perturbations of harmonic oscillator type self-adjoint operators are fulfilled. In both the linear and nonlinear case we calculate numerically the shifts of the unperturbed levels with quantum numbers n of up to 89 in dependence on the strength of the non-Hermiticity and compare with rigorous estimates derived by those authors. We confirm that the predicted 1/n1/2 estimate provides a valid upper bound on the shrink rate of the numerical eigenvalues. Moreover, we find that a more recent estimate of log(n/n3/2 is in excellent agreement with the numerical results. With nonlinearity the shrink rates are found to be smaller than without nonlinearity, and the rigorous estimates, derived only for the linear case, are no longer applicable.

  7. Comparison of the 2-step tuberculin skin test and QuantiFERON-TB Gold in-Tube test in the screening of latent tuberculosis infection in cancer patients

    Directory of Open Access Journals (Sweden)

    Hala A. Mohammad

    2015-07-01

    Hematological malignancy group (HMgroup had significantly more positive TSTII results followed by the breast cancer group (p = 0.01. Similarly, QFT-GIT positive values were significantly more frequent in the HM group. This study suggests that the QFT-GIT test maintains its sensitivity and performance in immunocompromised cancer patients, identifying a large number of truly infected patients being anergy to the tuberculin skin test.

  8. A Cryogen Recycler with Pulse Tube Cryocooler for Recondensing Helium and Nitrogen

    Science.gov (United States)

    Wang, C.; Lichtenwalter, B.

    2015-12-01

    We have developed a cryogen recycler using a 4 K pulse tube cryocooler for recondensing helium and nitrogen in a NMR magnet. The liquid helium cooled NMR magnet has a liquid nitrogen cooled radiation shield. The magnet boils off 0.84 L/day of liquid helium and 6 L/day of liquid nitrogen. The recycler is designed with both a liquid helium return tube and a liquid nitrogen return tube, which are inserted into the fill ports of liquid helium and nitrogen. Therefore the recycler forms closed loops for helium and nitrogen. A two-stage 4 K pulse tube cryocooler, Cryomech model PT407 (0.7W at 4.2 K), is selected for the recycler. The recycler was first tested with a Cryomech's test cryostat and resulted in the capacities of recondensing 8.2 L/day of nitrogen and liquefying 4 L/day of helium from room temperature gas. The recycler has been installed in the NMR magnet at University of Sydney since August, 2014 and continuously maintains a zero boil off for helium and nitrogen.

  9. Feeding tube - infants

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007235.htm Feeding tube - infants To use the sharing features on this page, please enable JavaScript. A feeding tube is a small, soft, plastic tube placed ...

  10. Performance test results of helium gas circulator of mock-up test facility with full-scale reaction tube for HTTR hydrogen production system. Contract research

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Akira; Kato, Michio; Hayashi, Koji [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment] [and others

    2003-03-01

    Hydrogen production system by steam reforming of methane will be connected to the High Temperature Engineering Test Reactor (HTTR) of the Japan Atomic Energy Research Institute (JAERI) against development of nuclear heat utilization system. To obtain design and safety database of the HTTR hydrogen production system, mock-up test facility with full-scale reaction was constructed in FY 2001 and hydrogen of 120m{sup 3}N{sub /}h was successfully produced in overall performance test. This report describes performance test results of a helium gas circulator in this facility. The circulator performance curves regarding to pressure-rise, input power and adiabatic thermal efficiency at standard revolution number were made based on the measured flow-rate, temperature and pressure data in overall performance test. The circulator performance prediction code was made based on these performance curves. The code can calculate revolution number, electric power and temperature-rise of the circulator using flow-rate, inlet temperature, inlet pressure and pressure-rise data. The verification of the code was carried out with the test data in FY 2002. Total pressure loss of the helium gas circulation loop was also evaluated. The circulator should be operated in conditions such as pressure from 2.7MPa to 4.0MPa and flow-rate from 250g/s to 400g/s and at maximum pressure-rise of 250 kPa in test operation. It was confirmed in above verification and evaluations that the circulator had performance to satisfy above conditions within operation limitation of the circulator such as maximum input-power of 150 kW and maximum revolution number of 12,000 rpm. (author)

  11. Tube-shape verifier

    Science.gov (United States)

    Anderson, A. N.; Christ, C. R.

    1980-01-01

    Inexpensive apparatus checks accuracy of bent tubes. Assortment of slotted angles and clamps is bolted down to flat aluminum plate outlining shape of standard tube bent to desired configuration. Newly bent tubes are then checked against this outline. Because parts are bolted down, tubes can be checked very rapidly without disturbing outline. One verifier per tube-bending machine can really speed up production in tube-bending shop.

  12. Expanding access to HIV viral load testing: a systematic review of RNA stability in EDTA tubes and PPT beyond current time and temperature thresholds.

    Directory of Open Access Journals (Sweden)

    Kimberly Bonner

    Full Text Available BACKGROUND: HIV viral load (VL testing is the gold standard for antiretroviral treatment monitoring, but many barriers exist to VL testing in resource-limited settings, including storage and transport limitations for whole blood and plasma. Data from various studies indicate that HIV RNA is stable beyond current recommendations. We conducted a systematic review to assess stability data of HIV RNA in whole blood and plasma across times and temperatures. METHODS AND FINDINGS: Using a pre-defined protocol, five databases were searched for studies where blood samples from HIV patients were stored at time and temperature points that exceeded manufacturer recommendations. RNA stability, the primary outcome, was measured by the difference in means compared to samples stored within established thresholds. RNA stability was defined as ≤0.5 log degradation. The search identified 10,716 titles, of which nine full-text articles were included for review. HIV RNA maintained stability in EDTA whole blood and plasma at all measured time points up to 168 hours when stored at 4°C, while stability was detected at 72 hours (95% confidence in whole blood at 25°C, with data points before and beyond 72 hours suggesting stability but not reaching statistical significance. For EDTA plasma stored at 30°C, stability was maintained up to 48 hours (95% confidence, with OLS linear regression estimates up to 127 hours, suggesting stability. Overall, quality of studies was moderate. Limitations included small sample sizes, few studies meeting inclusion criteria, and no studies examining RNA stability in low viremia (<3,000 copies/mL environments. CONCLUSIONS: Whole blood and plasma samples in EDTA may remain stable under conditions exceeding current manufacturer recommendations for HIV VL testing. However, given the limited number of studies addressing this question, especially at low levels of viremia, additional evaluations on HIV RNA stability in EDTA tubes and PPT in

  13. Incidence of tuberculosis among children living in contact with smear-positive tuberculosis: Advantages and limits of the Quantiferon TB gold in tube test.

    Science.gov (United States)

    Hannoun, Djohar; Boulahbal, Fadila

    2016-12-01

    Children living in contact with smear-positive pulmonary tuberculosis (TB) patients are highly exposed to TB infection. Our objective was to estimate the incidence of TB in children living in contact with a Smear Positive (M+) pulmonary tuberculosis (PTM+) index case during 2years following exposure. This was a descriptive, cohort, prospective, multicenter study of children aged from 6months to 15years in contact with a PTM+ case. The recruitment of children has been based on the diagnosed PTM+ index case and taken in charge by the Services of Control of Tuberculosis and Respiratory Diseases located in Algiers during 2014. Seven centers were selected. All children were tested using the Quantiferon TB gold in tube (QTR) test and the tuberculin skin test (TST). For TST, an induration diameter ⩾10mm was considered positive. We included 456 children living in contact with a PTM+ patient. The results for TST and QFT were available for 319 children. The mean age of the children was 6.7years (standard deviation=3.9). The sex ratio (Male/Female) was 1.26, and 15.8% (50) did not have a Bacilli of Calmette & Guerin (BCG) vaccination scar. Among the children, 46.1% (147) and 43.4% (138) were positive for QFT and TST, respectively, and 6.1% (19) have received isoniazid preventive therapy. Fifty-one children progressed to TB and received antitubercular treatment. We analyzed and compared our results between children who progressed to TB and those who did not progress to TB. Finally, we discuss our methodology and results in relation to the literature. Copyright © 2016.

  14. Thermomechanical Model and Bursting Tests to Evaluate the Risk of Swelling and Bursting of Modified 9Cr-1Mo Steel Steam Generator Tubes during a Sodium-Water Reaction Accident

    Directory of Open Access Journals (Sweden)

    C. Bertrand

    2014-01-01

    Full Text Available The MECTUB code was developed to evaluate the risk of swelling and bursting of Steam Generator (SG tubes. This code deals with the physic of intermediate steam-water leaks into sodium which induce a Sodium-Water Reaction (SWR. It is based on a one-dimensional calculation to describe the thermomechanical behavior of tubes under a high internal pressure and a fast external overheating. The mechanical model of MECTUB is strongly correlated with the kind of the material of the SG tubes. It has been developed and validated by using experiments performed on the alloy 800. A change to tubes made of Modified 9Cr-1Mo steel requires more knowledge of Modified 9Cr-1Mo steel behavior which influences the bursting time at high temperatures (up to 1200°C. Studies have been initiated to adapt the mechanical model and to qualify it for this material. The first part of this paper focuses on the mechanical law modelling (elasticity, plasticity, and creep for Modified 9Cr-1Mo steel and on overheating thermal data. In a second part, the results of bursting tests performed on Modified 9Cr-1Mo tubes in the SQUAT facility of CEA are used to validate the mechanical model of MECTUB for the Modified 9Cr-1Mo material.

  15. Use of Hydrogen Chemisorption and Ethylene Hydrogenation as Predictors for Aqueous Phase Reforming of Lactose over Ni@Pt and Co@Pt Bimetallic Overlayer Catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Qinghua; Skoglund, Michael D.; Zhang, Chen; Morris, Allen R.; Holles, Joseph H.

    2016-10-20

    Overlayer Pt on Ni (Ni@Pt) or Co (Co@Pt) were synthesized and tested for H2 generation from APR of lactose. H2 chemisorption descriptor showed that Ni@Pt and Co@Pt overlayer catalysts had reduced H2 adsorption strength compared to a Pt only catalyst, which agree with computational predictions. The overlayer catalysts also demonstrated lower activity for ethylene hydrogenation than the Pt only catalyst, which likely resulted from decreased H2 binding strength decreasing the surface coverage of H2. XAS results showed that overlayer catalysts exhibited higher white line intensity than the Pt catalyst, which indicates a negative d-band shift for the Pt overlayer, further providing evidence for overlayer formation. Lactose APR studies showed that lactose can be used as feedstock to produce H2 and CO under desirable reaction conditions. The Pt active sites of Ni@Pt and Co@Pt overlayer catalysts showed significantly enhanced H2 production selectivity and activity when compared with that of a Pt only catalyst. The single deposition overlayer with the largest d-band shift showed the highest H2 activity. The results suggest that overlayer formation using directed deposition technique could modify the behavior of the surface metal and ultimately modify the APR activity.

  16. Agreement between QuantiFERON(R)-TB Gold In-Tube and the tuberculin skin test and predictors of positive test results in Warao Amerindian pediatric tuberculosis contacts

    NARCIS (Netherlands)

    Verhagen, L.M.; Maes, M.; Villalba, J.A.; d'Alessandro, A.; Rodriguez, L.P.; Espana, M.F.; Hermans, P.W.M.; Waard, J.H. de

    2014-01-01

    BACKGROUND: Interferon-gamma release assays have emerged as a more specific alternative to the tuberculin skin test (TST) for detection of tuberculosis (TB) infection, especially in Bacille Calmette-Guerin (BCG) vaccinated people. We determined the prevalence of Mycobacterium tuberculosis infection

  17. Social media for message testing: a multilevel approach to linking favorable viewer responses with message, producer, and viewer influence on YouTube.

    Science.gov (United States)

    Paek, Hye-Jin; Hove, Thomas; Jeon, Jehoon

    2013-01-01

    To explore the feasibility of social media for message testing, this study connects favorable viewer responses to antismoking videos on YouTube with the videos' message characteristics (message sensation value [MSV] and appeals), producer types, and viewer influences (viewer rating and number of viewers). Through multilevel modeling, a content analysis of 7,561 viewer comments on antismoking videos is linked with a content analysis of 87 antismoking videos. Based on a cognitive response approach, viewer comments are classified and coded as message-oriented thought, video feature-relevant thought, and audience-generated thought. The three mixed logit models indicate that videos with a greater number of viewers consistently increased the odds of favorable viewer responses, while those presenting humor appeals decreased the odds of favorable message-oriented and audience-generated thoughts. Some significant interaction effects show that videos produced by laypeople may hinder favorable viewer responses, while a greater number of viewer comments can work jointly with videos presenting threat appeals to predict favorable viewer responses. Also, for a more accurate understanding of audience responses to the messages, nuance cues should be considered together with message features and viewer influences.

  18. Molybdenum-Doped PdPt@Pt Core-Shell Octahedra Supported by Ionic Block Copolymer-Functionalized Graphene as a Highly Active and Durable Oxygen Reduction Electrocatalyst.

    Science.gov (United States)

    Cho, Kie Yong; Yeom, Yong Sik; Seo, Heun Young; Kumar, Pradip; Lee, Albert S; Baek, Kyung-Youl; Yoon, Ho Gyu

    2017-01-18

    Development of highly active and durable electrocatalysts that can effectively electrocatalyze oxygen reduction reactions (ORR) still remains one important challenge for high-performance electrochemical conversion and storage applications such as fuel cells and metal-air batteries. Herein, we propose the combination of molybdenum-doped PdPt@Pt core-shell octahedra and the pyrene-functionalized poly(dimethylaminoethyl methacrylate)-b-poly[(ethylene glycol) methyl ether methacrylate] ionic block copolymer-functionalized reduced graphene oxide (Mo-PdPt@Pt/IG) to effectively augment the interfacial cohesion of both components using a tunable ex situ mixing strategy. The rationally designed Mo-PdPt@Pt core-shell octahedra have unique compositional benefits, including segregation of Mo atoms on the vertexes and edges of the octahedron and 2-3 shell layers of Pt atoms on a PdPt alloy core, which can provide highly active sites to the catalyst for ORR along with enhanced electrochemical stability. In addition, the ionic block copolymer functionalized graphene can facilitate intermolecular charge transfer and good stability of metal NPs, which arises from the ionic block copolymer interfacial layer. When the beneficial features of the Mo-PdPt@Pt and IG are combined, the Mo-PdPt@Pt/IG exhibits substantially enhanced activity and durability for ORR relative to those of commercial Pt/C. Notably, the Mo-PdPt@Pt/IG shows mass activity 31-fold higher than that of Pt/C and substantially maintains high activities after 10 000 cycles of intensive durability testing. The current study highlights the crucial strategies in designing the highly active and durable Pt-based octahedra and effective combination with functional graphene supports toward the synergetic effects on ORR.

  19. Unsupported NiPt alloy metal catalysts prepared by water-in-oil (W/O) microemulsion method for methane cracking

    KAUST Repository

    Zhou, Lu

    2016-05-18

    Unsupported NiPt metal catalyst with Ni/Pt molar ratio of 88/12 is prepared by water-in-oil (W/O) microemulsion method in this study. Compared to monometallic Ni and Pt catalysts, the NiPt catalyst exhibits superior activity and stability for methane cracking. By XRD (X-ray powder diffraction), XPS (X-ray photoelectron spectroscopy) and TEM (Transmission electron microscopy) analyses, the formation of Ni(0)Pt(0) alloy is believed to be the main reason for the reactivity improvement of this catalyst. Carbon nano tube (CNT) with Ni(0)Pt(0) particles anchored on the top of tube are found for the NiPt catalyst. © 2016 Elsevier Ltd.

  20. Experimental and calculation results of the integral reflood test QUENCH-15 with ZIRLO{sup TM} cladding tubes in comparison with results of previous QUENCH tests

    Energy Technology Data Exchange (ETDEWEB)

    Stuckert, J., E-mail: juri.stuckert@kit.edu [Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, D-76344 Eggenstein-Leopoldshafen (Germany); Birchley, J. [Paul Scherrer Institut (PSI), CH-5232 Villigen PSI (Switzerland); Grosse, M. [Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, D-76344 Eggenstein-Leopoldshafen (Germany); Jaeckel, B. [Paul Scherrer Institut (PSI), CH-5232 Villigen PSI (Switzerland); Steinbrueck, M. [Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, D-76344 Eggenstein-Leopoldshafen (Germany)

    2011-08-15

    Highlights: > Neither breakaway effect nor melt relocation was observed during a test with the ZIRLO{sup TM} bundle flooded at 2100 K. > A noticeable factor of cladding oxidation can be oxide growth at inner cladding surface. > Correlations developed for Zircaloy-4 are able to well reproduce oxidation kinetics of ZIRLO{sup TM}. - Abstract: The QUENCH-15 experiment investigated the effect of ZIRLO{sup TM} cladding material on bundle oxidation and core reflood, in comparison with tests QUENCH-06 (standard Zircaloy-4), QUENCH-12 (VVER, E110), and QUENCH-14 (M5). The QUENCH-15 bundle cross-section corresponded to a Westinghouse PWR core design and consisted of 24 heated rods (internal tungsten heaters between 0 and 1024 mm axial elevation, cladding oxidised region between -470 and 1500 mm), six corner rods made of Zircaloy-4, two corner rods made of E110, and a Zirconium 702 shroud. The test was conducted in principle with the same protocol as QUENCH-06, -12 and -14, so that the effects of the change of cladding material and bundle geometry could be more easily observed. The test protocol involved pre-oxidation to a maximum of about 150 {mu}m oxide thickness at a temperature of about 1473 K over a period of about 3000s. The power was then ramped at a rate of 0.25 W/s/rod to cause a temperature increase until the desired maximum bundle temperature of 2153 K was reached. The maximum oxide layer thickness observed was 380 {mu}m. Then reflood with 1.3 g/s/rod water at room temperature was initiated. The electrical power was reduced to 175 W/rod during the reflood phase, approximating effective decay heat level. The post-test metallography of the bundle showed neither noticeable breakaway oxidation of the cladding nor melt release into space between rods. The average outer oxide layer thickness at hottest elevation of 950 mm was 620 {mu}m (QUENCH-06: 630 {mu}m). The molten cladding metal at hottest elevation was localised between the outer and inner oxide layers. The

  1. Method of tube diffusion test detecting β-lactam antibiotics residue in raw milk%试管扩散法检测牛乳中β-酰胺类抗生素残留研究

    Institute of Scientific and Technical Information of China (English)

    吴瑕; 邵辉; 王鑫; 张兰威

    2011-01-01

    试管扩散法是以微生物受阻法为基本原理.用嗜热脂肪芽孢杆茵作为指示茵.在培养基中加入指示剂,根据嗜热脂肪芽孢杆茵在生乳中生长产酸使指示剂变色现象,确定牛乳中β-内酰胺类抗生素残留量,比较试管扩散法和TTC法检测牛乳中6种β-内酰胺类抗生素残留得到的检测限和检测时间等指标.结果表明,试管扩散法比TTC法更适合国内牛乳中β-内酰胺类抗生素残留的检测.%The principle of the tube diffusion test was based on the method of microbiological inhibitor. Bacillus stearothermophilus was used as the test bacteria. And the indicator was added into the test medium. Six kinds of β-Iactam antibiotics were tested at five concentrations based on established codex alimentarius maximum residue limits (MRLs) by two methods of the tube diffusion test and TTC. The detecting results indicated that the tube diffusion test was better than TTC in detecting β-lactam antibiotics residue in raw milk in China.

  2. Metal hydrides studied in gas discharge tube

    Science.gov (United States)

    Bozhinova, I.; Kolev, S.; Popov, Tsv.; Pashov, A.; Dimitrova, M.

    2016-05-01

    A novel construction of gas discharge tube has been tested for production of high densities of metal hydrydes. Its performance turned out to be comparable with the existing sources of the same type and even better. First results of the tests on NiH are reported and critically analysed. Plans for future modifiaction of the construction and application of the tube are discussed.

  3. Mycobacterium Tuberculosis Infection, Immigration Status, and Diagnostic Discordance: A Comparison of Tuberculin Skin Test and QuantiFERON-TB Gold In-Tube Test Among Immigrants to the U.S.

    Science.gov (United States)

    Wilson, Fernando A; Miller, Thaddeus L; Stimpson, Jim P

    2016-01-01

    We used a recent source of nationally representative population data on tuberculosis (TB) infection to characterize concordance between the tuberculin skin test (TST) and the QuantiFERON-TB Gold In-Tube (QFT-GIT) blood test for immigrants in the United States. We used TB screening data from the 2011-2012 National Health and Nutrition Examination Survey to examine concordance between the TST and QFT-GIT--an interferon-gamma release assay (IGRA) blood test--for 7,097 U.S. natives, naturalized citizens, and noncitizens. Consistent with prior findings, one in five immigrants in the survey was identified with latent TB infection (LTBI), a rate 14 times higher than for U.S. natives. We also found higher rates of discordant TST/IGRA results among immigrants than among U.S. natives. Unadjusted discordance between TST and IGRA was 3% among U.S. natives (weighted N=5,684,274 of 191,179,213) but ranged up to 19% for noncitizens (weighted N=3,722,960 of 19,377,147). Adjusting for age, sex, and race/ethnicity, noncitizens had more than nine times the odds of having a positive TST result but negative QFT-GIT result compared with U.S. natives. Our findings suggest that whether and how either of these tests should be deployed is highly context sensitive. Significant discordance in test results when used among immigrants raises the possibility of missed opportunities for harm reduction in this already at-risk population. However, we found little distinction between the tests in terms of diagnostic outcome when used in a U.S. native population, suggesting little benefit to the adoption and use of the QFT-GIT test in place of TST on the basis of test performance alone for this population.

  4. Performance of multi tubes in tube helically coiled as a compact heat exchanger

    Science.gov (United States)

    Nada, S. A.; El Shaer, W. G.; Huzayyin, A. S.

    2014-12-01

    Multi tubes in tube helically coiled heat exchanger is proposed as a compact heat exchanger. Effects of heat exchanger geometric parameters and fluid flow parameters; namely number of inner tubes, annulus hydraulic diameter, Reynolds numbers and input heat flux, on performance of the heat exchanger are experimentally investigated. Different coils with different numbers of inner tubes, namely 1, 3, 4 and 5 tubes, were tested. Results showed that coils with 3 inner tubes have higher values of heat transfer coefficient and compactness parameter (bar{h} Ah ). Pressure drop increases with increasing both of Reynolds number and number of inner tubes. Correlations of average Nusselt number were deduced from experimental data in terms of Reynolds number, Prandtl number, Number of inner coils tubes and coil hydraulic diameter. Correlations prediction was compared with experimental data and the comparison was fair enough.

  5. Development boiling to sprinkled tube bundle

    Directory of Open Access Journals (Sweden)

    Kracík Petr

    2016-01-01

    Full Text Available This paper presents results of a studied heat transfer coefficient at the surface of a sprinkled tube bundle where boiling occurs. Research in the area of sprinkled exchangers can be divided into two major parts. The first part is research on heat transfer and determination of the heat transfer coefficient at sprinkled tube bundles for various liquids, whether boiling or not. The second part is testing of sprinkle modes for various tube diameters, tube pitches and tube materials and determination of individual modes’ interface. All results published so far for water as the falling film liquid apply to one to three tubes for which the mentioned relations studied are determined in rigid laboratory conditions defined strictly in advance. The sprinkled tubes were not viewed from the operational perspective where there are more tubes and various modes may occur in different parts with various heat transfer values. The article focuses on these processes. The tube is located in a low-pressure chamber where vacuum is generated using an exhauster via ejector. The tube consists of smooth copper tubes of 12 mm diameter placed horizontally one above another.

  6. Development boiling to sprinkled tube bundle

    Science.gov (United States)

    Kracík, Petr; Pospíšil, Jiří

    2016-03-01

    This paper presents results of a studied heat transfer coefficient at the surface of a sprinkled tube bundle where boiling occurs. Research in the area of sprinkled exchangers can be divided into two major parts. The first part is research on heat transfer and determination of the heat transfer coefficient at sprinkled tube bundles for various liquids, whether boiling or not. The second part is testing of sprinkle modes for various tube diameters, tube pitches and tube materials and determination of individual modes' interface. All results published so far for water as the falling film liquid apply to one to three tubes for which the mentioned relations studied are determined in rigid laboratory conditions defined strictly in advance. The sprinkled tubes were not viewed from the operational perspective where there are more tubes and various modes may occur in different parts with various heat transfer values. The article focuses on these processes. The tube is located in a low-pressure chamber where vacuum is generated using an exhauster via ejector. The tube consists of smooth copper tubes of 12 mm diameter placed horizontally one above another.

  7. Measurement of the (gamma,n) reaction rates of the nuclides 190Pt, 192Pt, and 198Pt in the astrophysical gamma-process

    CERN Document Server

    Vogt, K; Babilon, M; Enders, J; Hartmann, T; Hutter, C; Rauscher, T; Volz, S; Zilges, A

    2001-01-01

    The nucleosynthesis of heavy neutron-deficient nuclei in a stellar photon bath at the temperatures relevant for the astrophysical gamma process was investigated. In order to derive (gamma,n) cross sections and reaction rates, the stellar photon bath was simulated by the superposition of several bremsstrahlung spectra with different endpoint energies. As a first test for this method, the (gamma,n) reaction rates of the platinum isotopes 190Pt, 192Pt, and 198Pt were derived. The results are compared to other experimental data and theoretical calculations.

  8. Factors that Predict Negative Results of QuantiFERON-TB Gold In-Tube Test in Patients with Culture-Confirmed Tuberculosis: A Multicenter Retrospective Cohort Study.

    Directory of Open Access Journals (Sweden)

    Yong-Soo Kwon

    Full Text Available Interferon-γ release assays such as the QuantiFERON-TB Gold In-Tube Test (QFT-GIT are designed to detect Mycobacterium tuberculosis infections, whether latent or manifesting as disease. However, a substantial number of persons with culture-confirmed tuberculosis (TB have negative QFT-GITs. Information on host factors contributing to false-negative and indeterminate results are limited.A multicenter retrospective cohort study was performed with 1,264 culture-confirmed TB patients older than 18 years who were subjected to the QFT-GIT at one of the six hospitals between May 2007 and February 2014. Patients with human immunodeficiency virus infection were excluded. Clinical and laboratory data were collected in South Korea.Of all patients, 87.6% (1,107/1,264 were diagnosed with pulmonary TB and 12.4% (157/1,264 with extrapulmonary TB. The rate of negative results was 14.4% (182/1,264. The following factors were highly correlated with false-negative results in the QFT-GIT: advanced age (age ≥ 65 years, odds ratio [OR] 1.57, 95% confidence interval [CI] 1.03-2.39, bilateral disease as determined by chest radiography (OR 1.75, 95% CI 1.13-2.72, malignancy (OR 2.42, 95% CI 1.30-4.49, and lymphocytopenia (total lymphocyte count < 1.0 × 109/L, OR 1.86, 95% CI 1.21-2.87.Consequently, QFT-GIT results need to be interpreted with caution in patients with these host risk factors such as the elderly, bilateral disease on chest radiography, or malignancy, or lymphocytopenia.

  9. Left-right differences in Eustachian tube function in children with ventilation tubes.

    NARCIS (Netherlands)

    Heerbeek, N. van; Akkerman, A.E.; Ingels, K.J.A.O.; Engel, J.A.M.; Zielhuis, G.A.

    2003-01-01

    OBJECTIVE: To study the intraindividual variation in Eustachian tube (ET) function in children with ventilation tubes. METHODS: The forced response test, the pressure equilibration test and the sniff test were performed on both ears of 148 children. The results of both ears were compared. RESULTS: N

  10. 基于超声对测法的钢管混凝土脱空检测试验%Experiment on Void Area Testing of Concrete-filled Steel Tube Based on Ultrasonic Testing Method

    Institute of Scientific and Technical Information of China (English)

    檀永杰; 徐波; 吴智敏; 何化南

    2012-01-01

    Four possible propagation paths in the disengaging by ultrasonic testing method for void area of concrete-filled steel tube were analyzed, and the theoretical calculation formulae of ultrasonic travel time for four propagation paths were given. From the comparisons between the experimental values and the theoretical values, the real propagation paths in the two kinds of disengaging were obtained, which provided the conditions for the quantitative test of the disengaging. With the interpolation function from MATLAB, matrix of ultrasonic travel time of the disengaging would be disposed, and the disengaging of the concrete-filled steel tube was got. Then the chromatogram of ultrasonic travel time distribution was drawn and it could be used for quantitative analysis. Finally, the applicable range of the central angle with the ultrasonic testing method was proposed. Results show that the chromatogram of ultrasonic travel time distribution based on ultrasonic testing method can reach the purposes of quantitative detection defects and can meet accuracy requirements of the project.%分析了超声波对测法在钢管混凝土脱空区4种可能的超声首波传播路径,并给出了4种传播路径的声时理论计算公式.通过试验得到了实际传播声时,并与由声时公式计算的理论值对比,得到了在2种脱空区范围内超声首波的传播路径,即沿绕射脱空缺陷传播,为超声对测法定量检测脱空区范围提供了条件;通过MATLAB的内插函数,将对测法得到的测区内各离散测点超声首波声时矩阵进行处理,得到整个测区的钢管混凝土脱空信息,基于此绘出脱空区声时分布色谱图,以达到定量检测的效果.最后给出了超声对测法适用的脱空缺陷对应的圆心角范围.结果表明:基于超声对测法的声时分布色谱图达到定量检测缺陷的目的,且满足工程精度要求.

  11. PtRu/C electrocatalysts prepared using {gamma}-irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Dionisio F.; Neto, Almir Oliveira; Pino, Eddy S.; Linardi, Marcelo; Spinace, Estevam V. [Instituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN-SP, Av. Professor Lineu Prestes, 2242, Cidade Universitaria, 05508-000 Sao Paulo, SP (Brazil)

    2007-07-10

    PtRu/C electrocatalysts (carbon-supported PtRu nanoparticles) were prepared submitting water/ethylene glycol solutions containing Pt(IV) and Ru(III) ions and the carbon support to {gamma}-irradiation. The water/ethylene glycol ratio (v/v) and the total dose (kGy) were evaluated as synthesis parameters. The electrocatalysts were characterized by energy dispersive X-ray analysis (EDX), X-ray diffraction (XRD), transmission electron microscopy (TEM) and cyclic voltammetry and tested for methanol electro-oxidation aiming fuel cell application. The obtained PtRu/C electrocatalysts were more active for methanol electro-oxidation than the commercial PtRu/C electrocatalyst at ambient temperature and the electrocatalytic activity depends on the water/ethylene glycol ratio used in the preparation. (author)

  12. Characterization of azo dyes on Pt and Pt/polyaniline/dispersed Pt electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Molina, J.; Fernandez, J.; Rio, A.I. del; Bonastre, J. [Departamento de Ingenieria Textil y Papelera, EPS de Alcoy, Universitat Politecnica de Valencia, Plaza Ferrandiz y Carbonell s/n, 03801 Alcoy (Spain); Cases, F., E-mail: fjcases@txp.upv.es [Departamento de Ingenieria Textil y Papelera, EPS de Alcoy, Universitat Politecnica de Valencia, Plaza Ferrandiz y Carbonell s/n, 03801 Alcoy (Spain)

    2012-06-15

    The electrochemical characterization of two organic dyes (amaranth and procion orange MX-2R) has been performed on Pt electrodes and Pt electrodes coated with polyaniline and dispersed Pt. Electrodes with different Pt loads have been synthesized and characterized obtaining that a load of 300 {mu}g cm{sup -2} was the optimum one. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) was employed to observe the distribution and morphology of the Pt nanoparticles. The electroactivity of the electrodes has also been characterized by means of scanning electrochemical microscopy (SECM). The chemical characterization of Pt dispersed Pani coated Pt electrodes (Pt-Pani-Pt) was performed by means of X-ray photoelectron spectroscopy (XPS). The electrochemical characterization of the dyes has been performed by means of cyclic voltammetry. Voltammograms have shown that the presence of the dyes diminishes characteristic Pt oxidation and reduction peaks. However, redox processes due to the dyes, appeared in the voltammograms. The different species responsible of these redox processes were generated in the vicinity of the electrode and were not adsorbed on the electrode surface since after stirring, the different redox processes disappeared. Characterization with different scan rates showed that redox processes of both dyes were controlled by diffusion.

  13. Hybrid endotracheal tubes

    Science.gov (United States)

    Sakezles, Christopher Thomas

    Intubation involves the placement of a tube into the tracheal lumen and is prescribed in any setting in which the airway must be stabilized or the patient anesthetized. The purpose of the endotracheal tube in these procedures is to maintain a viable airway, facilitate mechanical ventilation, allow the administration of anesthetics, and prevent the reflux of vomitus into the lungs. In order to satisfy these requirements a nearly airtight seal must be maintained between the tube and the tracheal lining. Most conventional endotracheal tubes provide this seal by employing a cuff that is inflated once the tube is in place. However, the design of this cuff and properties of the material are a source of irritation and injury to the tracheal tissues. In fact, the complication rate for endotracheal intubation is reported to be between 10 and 60%, with manifestations ranging from severe sore throat to erosion through the tracheal wall. These complications are caused by a combination of the materials employed and the forces exerted by the cuff on the tracheal tissues. In particular, the abrasive action of the cuff shears cells from the lining, epithelium adhering to the cuff is removed during extubation, and normal forces exerted on the basement tissues disrupt the blood supply and cause pressure necrosis. The complications associated with tracheal intubation may be reduced or eliminated by employing airway devices constructed from hydrogel materials. Hydrogels are a class of crosslinked polymers which swell in the presence of moisture, and may contain more than 95% water by weight. For the current study, several prototype airway devices were constructed from hydrogel materials including poly(vinyl alcohol), poly(hydroxyethyl methacrylate), and poly(vinyl pyrrolidone). The raw hydrogel materials from this group were subjected to tensile, swelling, and biocompatibility testing, while the finished devices were subjected to extensive mechanical simulation and animal trials

  14. Charge optimized many body (COMB) potentials for Pt and Au

    Science.gov (United States)

    Antony, A. C.; Akhade, S. A.; Lu, Z.; Liang, T.; Janik, M. J.; Phillpot, S. R.; Sinnott, S. B.

    2017-06-01

    Interatomic potentials for Pt and Au are developed within the third generation charge optimized many-body (COMB3) formalism. The potentials are capable of reproducing phase order, lattice constants, and elastic constants of Pt and Au systems as experimentally measured or calculated by density functional theory. We also fit defect formation energies, surface energies and stacking fault energies for Pt and Au metals. The resulting potentials are used to map a 2D contour of the gamma surface and simulate the tensile test of 16-grain polycrystalline Pt and Au structures at 300 K. The stress-strain behaviour is investigated and the primary slip systems {1 1 1} are identified. In addition, we perform high temperature (1800 K for Au and 2300 K for Pt) molecular dynamics simulations of 30 nm Pt and Au truncated octahedron nanoparticles and examine morphological changes of each particle. We further calculate the activation energy barrier for surface diffusion during simulations of several nanoseconds and report energies of 0.62+/- 0.16 eV for Pt and 1.44+/- 0.06 eV for Au. This initial parameterization and application of the Pt and Au potentials demonstrates a starting point for the extension of these potentials to multicomponent systems within the COMB3 framework.

  15. Optimization of a Shell and Tube Condenser using Numerical Method

    Directory of Open Access Journals (Sweden)

    Pradeep Wagh

    2015-07-01

    Full Text Available The purpose of this study was to investigate the effect of installation of the tube external surfaces, their parameter and variable in a shell-and-tube condenser. Variation of heat transfer coefficient with each variable of shell and tube condenser was measured each test. The optimization tube outside diameter size was analyzed and use extended surface area attached tube with tube material and tube layout and arrangement (Number of tube a triangular or hexagonal arrangement on shell-and tube condenser. The computer programming was used to get faster output in less time. Results suggest that mean heat transfer coefficient in variable condition were mainly at velocity is fixed. And also average additional surfaces and tube layout and the arrangement comparison with the quantity of the heat transfer.

  16. Energy absorbing efficiency of various aluminum foam filled tube

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jin Man; Lee, Won Sik; Ko, Se Hyun [Korea Institute of Industrial Technology, Chonan (Korea, Republic of)

    2005-04-15

    In this study various types of A1 foam filled tubes were fabricated using foam of A1-12wt.%Si by powder metallurgical process. Their energy absorbing efficiencies were investigated with compression test, focusing on the structure and bonding effects between tube and foam. The results show that the energy absorption is affected by structure of A1 foam filled tube. Among fully foam filled tube, partially foam filled tube and A1 hollow tube with the same weight, fully foam filled tube seems to have superior potential for industrial application to energy absorption parts. Also energy absorption efficiency is increased by interaction between tube and foam and especially, bonding between tube and metallic foam gives rise to increase the energy absorption efficiency up to above 1.2 times. This results from the arrest of folding of tube by metallic foam and the change of stress mode from uni-axial to multi-axial during compression.

  17. 转基因败育毛白杨雄株试管苗气孔行为观察%Observation of the Stomatal Behavior of Test-tube Plantlet of Transgenic Male Abortive Populus tomentosa Carr

    Institute of Scientific and Technical Information of China (English)

    杨金华; 朱美秋; 杜克久

    2011-01-01

    [Objective] To study the causes of abnormal stomatal behavior of test-tube plantlet. [ Method ] The change of stomatal density, stomatal size, the daily variation of stomatal aperture and stomatal open percentage of the leaves' lower epidermis of test-tube plantlets and 10-year-old plants of transgenic male abortive Populus tomentosa Carr were observed and compared in this paper by using nail polish method. [Result] The stomatal density of test-tube plantlets was less than that of the 10-year-old plant; test-tube plantlets' stomata was obviously larger than that of the 10-year-old plant; the stomatal aperture of test-tube plantlets showed wave crest, and the two peaks appeared at 9:00 and 15 :00,10-year-old plant had steady curve without evident fluctuation,and the stomatal aperture in test-tube plantlets was greater than that in the 10-year-old plant; stomatal open percentage reached 100% in test-tube plantlets during a day,a bimodal curve change was observed in stomatal open percentage of the 10-year-old plant. [Conclusion] Stomatal behavior were different between the test-tube plantlets and the 10-year-old plant of transgenic male abortive Populus tomentosa Carr.%[目的]探寻试管苗叶片气孔行为异常的原因.[方法]利用指甲油涂抹撕取法将转基因败育毛白杨雄株试管苗与10年生植株叶片下表皮制成切片,并对其气孔密度、气孔大小、气孔开度日变化、气孔开张率日变化进行观察比较.[结果]试管苗气孔密度小于10年生植株;试管苗气孔明显比10年生植株气孔大;试管苗气孔开度日变化呈明显波峰状,2个高峰分别出现在9:00和15:00,10年生植株曲线平稳,无明显波动,且试管苗气孔开度大于10年生植株;试管苗气孔开张率在一昼夜均为100%,10年生植株气孔开张率在一昼夜呈双曲线变化.[结论]转基因败育毛白杨雄株试管苗与10年生植株气孔行为存在差异.

  18. High temperature polymer electrolyte membrane fuel cell performance of Pt xCo y/C cathodes

    Science.gov (United States)

    Rao, Ch. Venkateswara; Parrondo, Javier; Ghatty, Sundara L.; Rambabu, B.

    Carbon-supported Pt-Co alloy nanoparticles of varying Pt:Co atomic ratios of 1:1, 2:1, 3:1 and 4:1 are prepared, characterized and tested in high temperature PEM fuel cell intend to reduce the Pt loading. These electrocatalysts are prepared by borohydride reduction method in the presence of citric acid as stabilizing agent. Face-centered cubic structure of Pt is evident from XRD. The positive shift of Pt diffraction peaks with increasing cobalt content in the Pt xCo y/C catalysts indicated the solubility of Co in Pt lattice. The average crystallite size is found to be 6 nm in all the prepared catalysts. The electrochemical active surface area (EAS) of the catalysts from CO-stripping voltammetry is calculated to be 65.2, 51.4, 47.7, 41.5 and 38.3 m 2 g -1 Pt for Pt/C, Pt-Co(4:1)/C, Pt-Co(3:1)/C, Pt-Co(2:1)/C and Pt-Co(1:1)/C, respectively. These catalysts are used as cathode in the fabrication of polybenzimidazole-based membrane electrode assembly (MEA) and the polarization curves are recorded at 160 and 180 °C. The results indicate the good performance of Pt-Co alloys than that of Pt under the PEM fuel cell conditions. Among the investigated electrocatalysts, Pt-Co(1:1)/C and Pt-Co(2:1)/C exhibited good fuel cell performance. Durability tests also indicated the good stability of Pt-Co(1:1)/C and Pt-Co(2:1)/C compared to Pt/C.

  19. Investigation of nano Pt and Pt-based alloys electrocatalysts for direct methanol fuel cells and their properties

    Directory of Open Access Journals (Sweden)

    Chunguang Suo

    2014-03-01

    Full Text Available The electrocatalysts used in micro direct methanol fuel cell (μDMFC, such as Pt/C and Pt alloy/C, prepared by liquid-phase NaBH4 reduction method have been investigated. XC-72 (Cobalt corp. Company, U.S.A is chosen as the activated carrier for the electrocatalysts to keep the catalysts powder in the range of several nanometers. The XRD, SEM, EDX analyses indicated that the catalysts had small particle size in several nanometers, in excellent dispersed phase and the molar ratio of the precious metals was found to be optimal. The performances of the DMFCs using cathodic catalyst with Pt percentage of 30wt% and different anodic catalysts (Pt-Ru, Pt-Ru-Mo were tested. The polarization curves and power density curves of the cells were measured to determine the optimal alloy composition and condition for the electrocatalysts. The results showed that the micro direct methanol fuel cell with 30wt% Pt/C as the cathodic catalyst and n(Pt:n(Ru:n(Mo = 3:2:2 PtRuMo/C as the anodic catalyst at room temperature using 2.0mol/L methanol solution has the best performances.

  20. Low Pt-content ternary PdCuPt nanodendrites: an efficient electrocatalyst for oxygen reduction reaction

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Shaofang; Zhu, Chengzhou; Song, Junhua; Zhang, Peina; Engelhard, Mark H.; Xia, Haibing; Du, Dan; Lin, Yuehe

    2017-01-01

    Dendritic nanostructures are capturing increasing attentions in electrocatalysis owing to their unique structural features and low density. Herein, we report for the first time bromide ions mediated synthesis of low-Pt-content PdCuPt ternary nanodendrites via galvanic replacement reaction between Pt precursor and PdCu template in aqueous solution. The experimental results show that the ternary PdCuPt nanodendrites present enhanced electrocatalytic performance for oxygen reduction reaction in acid solution compared with commercial Pt/C as well as some state-of-the-art catalysts. In details, the mass activity of the PdCuPt catalyst with optimized composition is 1.73 A/mgPt at 0.85 V vs RHE, which is 14 times higher than that of commercial Pt/C catalyst. Moreover, the long-term stability test demonstrates its better durability in acid solution. After 5k cycles, there is still 70% electrochemical surface area maintained. This method provides an efficient way to synthesize trimetallic alloys with controllable composition and specific structure for oxygen reduction reaction.

  1. Development and formability analysis of TRIP seamless steel tube

    Institute of Scientific and Technical Information of China (English)

    Zhang Zicheng; Zhu Fuxian

    2014-01-01

    In this paper, the production technology of transformation induced plasticity (TRIP) steel was first introduced into the steel tube manufacture field to produce the steel tubes with high strength and plasticity. The TRIP seamless steel tubes with the microstructure of ferrite, bainite, retained austenite and a little martensite were successfully fabricated using a cold-drawn steel tube with two-stage heat treatment technique and continu- ous heat treatment process, respectively. The ring tensile test and cold bend test were carried out to study the formability of the newly developed TRIP seamless steel tube. The results showed that the TRIP seamless steel tubes have a good cold formability, and they are available to be used in the tube hydroforming process. In ad- dition, the equipment of continuous heat treatment developed in the current study can be used to produce TRIP steel tube, and it may serve as an important reference for the industrial production of TRIP steel tube.

  2. Risks of Ovarian, Fallopian Tube, and Primary Peritoneal Cancer Screening

    Science.gov (United States)

    ... Screening Research Ovarian, Fallopian Tube, and Primary Peritoneal Cancer Screening (PDQ®)–Patient Version What is screening? Go to ... ovarian cancer. Ovarian, Fallopian Tube, and Primary Peritoneal Cancer Screening Key Points Tests are used to screen for ...

  3. Ovarian, Fallopian Tube, and Primary Peritoneal Cancer Screening

    Science.gov (United States)

    ... Screening Research Ovarian, Fallopian Tube, and Primary Peritoneal Cancer Screening (PDQ®)–Patient Version What is screening? Go to ... ovarian cancer. Ovarian, Fallopian Tube, and Primary Peritoneal Cancer Screening Key Points Tests are used to screen for ...

  4. Glycol/water evacuated-tube solar collector

    Science.gov (United States)

    1980-01-01

    Report describes performance of 8 tube and 10 tube commercially produced solar collectors. Tests include thermal efficiency, time constant for temperature drop after solar flux is cut, change in efficiency with Sun angle, and temperature rise if circulation is stopped.

  5. Feeding tube insertion - gastrostomy

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002937.htm Feeding tube insertion - gastrostomy To use the sharing features on this page, please enable JavaScript. A gastrostomy feeding tube insertion is the placement of a feeding ...

  6. Neural Tube Defects

    Science.gov (United States)

    Neural tube defects are birth defects of the brain, spine, or spinal cord. They happen in the ... that she is pregnant. The two most common neural tube defects are spina bifida and anencephaly. In ...

  7. Condensation of Refrigerant-11 on the outside of horizontal and inclined enhanced tubes

    Energy Technology Data Exchange (ETDEWEB)

    Domingo, N.

    1982-12-01

    Heat transfer condensation tests with Refrigerant-11 were performed on the outside of a smooth tube and a variety of enhanced tubes oriented horizontally and at various tube inclinations. One smooth tube and seven enhanced (externally fluted, roped, spiraled, and externally finned) tubes of 2.54-cm (1-in.) nominal outside diameter and 1.17-m (4-ft) length were tested. Several of the tested tubes featured internal enhanced geometries, which were caused by the heat transfer enhancing geometry on the tube's external surface. Condensing heat transfer coefficients are reported as composite coefficients, which combine the resistance of the condensing film and the tube wall, and are based on total tube outside surface area. Results show that in the horizontal condensing mode, the rank order (best to worst) of the tube geometries tested was spiral-shaped tubes, rope-shaped tubes, smooth tube, externally finned tube, and externally fluted tube. For a spiral-shaped tube, horizontal composite coefficients were up to 2.0 times the corresponding horizontal smooth tube values. For tilt angles greater than or equal to 60/sup 0/ from the horizontal, the condensing performance of the externally fluted tube was best of all the tubes tested.

  8. Graphene supported nano particles of Pt-Ni for CO oxidation

    Science.gov (United States)

    Zhang, Cheng; Lv, Wei; Yang, Quanhong; Liu, Yuan

    2012-08-01

    In this study, a series of graphene supported Pt, Ni and Pt-Ni nano particles were successfully synthesized by a simple impregnation method. The resultant composites were characterized using SEM, XRD, HRTEM, XPS and TPR techniques and their catalytic performance for the oxidation of carbon monoxide was tested. It was shown that in the prepared metal/graphene composite, metal particles were highly dispersed on the graphene sheets (GS) with an average particle size of 1-3 nm. The results of catalytic performance tests indicate that the activity decreases in the order of Pt-Ni/GS, Pt/GS and Ni/GS. In the sample of Pt-Ni/GS, Pt-Ni alloy was formed, which contributed to the high activity of Pt-Ni/GS for CO oxidation.

  9. Effect of cultural conditions on the seed-to-seed growth of Arabidopsis and Cardamine - A study of growth rates and reproductive development as affected by test tube seals

    Science.gov (United States)

    Hoshizaki, T.

    1982-01-01

    The effects of test tube seals on the growth, flowering, and seed pod formation of Arabidopsis thaliana (L.) Heynh., mouse ear cress, and Cardamine oligosperma Nutt, bitter cress, are studied in order to assess the conditions used in weightlessness experiments. Among other results, it is found that the growth (height) and flowering (date of bud appearance) were suppressed in mouse ear cress in tubes sealed with Saran. Seed pod formation which occurred by day 45 in open-to-air controls, was still lacking in the sealed plants even up to day 124. The growth and flowering of bitter cress were also suppressed by the Saran seal, although up to day 55 the Saran-sealed plants were taller. It is suggested that atmospheric composition was the cause of the suppression of growth, flowering, and seed pod development in these plants, since the mouse ear cress renewed their growth and then set seed pods after the Saran seal was ruptured.

  10. The implications of soil acidification on a future HLW repository. Pt 2. Influence on deep granitic groundwater. The Klipperaas study site as test case.

    Energy Technology Data Exchange (ETDEWEB)

    Wersin, P.; Bruno, J. [MBT Tecnologia Ambiental, Cerdanyola (Spain); Laaksoharju, M. [Geopoint AB, Spaanga (Sweden)

    1994-05-01

    The effect of acidification on deep groundwater is assessed with a geochemical box model based on the STEADYQL code. The application of the model to the Klipperaas study site shows a remarkable agreement between observed and predicted groundwater composition and offers an adequate description of the geochemical evolution of the aquifer. Proton fluxes are shown to be controlled mainly by calcite weathering and organic carbon degradation processes. The impact of increased acidification is evaluated on the basis of various test cases and by including the soil compartment in the model framework. The results indicate that calcite weathering will be increased by a factor of two to three as a result of increased acidification. Furthermore, the calculations suggest that, once the powerful carbonate buffer is depleted, the buffer capacity is provided mainly by anaerobic respiration and ion exchange processes. Further ongoing acidic loading would lead to neutralization of alkalinity fluxes leaving the system with a very low buffering capacity towards fluctuations in proton fluxes. Estimation of time scales of aquifer acidification was assessed under the focus of calcite depletion with aid of two acidification scenarios. These predict a time range of 12400 to 370000 years for calcite depletion to take place down to 500 meters depth. It is suggested from inherent model assumptions that these estimated time scales are conservative. 53 refs.

  11. Prednisolone treatment affects the performance of the QuantiFERON gold in-tube test and the tuberculin skin test in patients with autoimmune disorders screened for latent tuberculosis infection

    DEFF Research Database (Denmark)

    Bélard, Erika; Semb, Synne; Ruhwald, Morten

    2011-01-01

    BACKGROUND: During screening for latent tuberculosis infection (LTBI), before anti-tumor-necrosis-factor-a treatment, most patients are already receiving immunosuppressive therapy. The objective was to evaluate the performance of the QuantiFERON Gold In-Tube (QFT-IT) and the Tuberculin Skin Test....../238 (23%) patients. Chest x-ray was suspect for tuberculosis in 5/236 (2%), and 35/167 (21%) had =1 risk-factors for infection with Mycobacterium tuberculosis. The main finding was a pronounced negative effect on QFT-IT and TST performance associated with prednisolone treatment. During prednisolone...... treatment interferon gamma (IFN-¿) response to mitogen stimulation was impaired (median IFN-¿ response 4.9 IU/mL; interquartile range [IQR] 0.8 to =10.0) compared to patients 1) not receiving corticosteroids (median =10.0; IQR 5.0 to =10.0; P = 0.0015) or 2) receiving long-acting corticosteroids (median >10...

  12. Preparation of PtRu/C and PtSn/C electrocatalysts using electron beam irradiation for direct and ethanol fuel cell; Preparacao de eletrocatalisadores PtRu/C e PtSn/C utilizando feixe de eletrons para aplicacao como anodo na oxidacao direta de metanol e etanol em celulas a combustivel de baixa temperatura

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Dionisio Furtunato da

    2009-07-01

    PtRu/C and PtSn/C electrocatalysts were prepared using electron beam irradiation. The metal ions were dissolved in water/2-propanol and water/ethylene glycol solutions and the carbon support was added. The resulting mixtures were irradiated under stirring. The effect of water/ethylene glycol and water/2-propanol (v/v) ratio, Pt:Ru and Pt:Sn atomic ratios, the irradiation time and dose rate were studied. The obtained materials were characterized by Energy dispersive analysis of X-rays (EDX), X-ray diffraction (XRD), cyclic voltammetry (CV) and Moessbauer spectroscopy. The electro-oxidation of methanol and ethanol were studied by cyclic voltammetry and chronoamperometry using the thin porous coating technique. The electrocatalysts were also tested on the Direct Methanol and Ethanol Fuel Cells. PtRu/C electrocatalysts prepared in water/ethylene glycol showed Pt:Ru atomic ratios different from the nominal ones. The results suggested that part of the Ru(III) ions were not reduced. The obtained materials showed the face-centered cubic (fcc) structure of Pt and Pt alloys with crystallite sizes of 2-3 nm. PtRu/C electrocatalysts prepared in water/2-propanol showed Pt:Ru atomic ratios similar to the nominal ones. The obtained materials also showed the fcc structure of platinum and platinum alloys with crystallite sizes of 3-4 nm. PtSn/C electrocatalysts prepared in water/ethylene glycol and water/2-propanol showed Pt:Sn atomic ratios similar to the nominal ones. The obtained materials showed the platinum (fcc) phase with crystallite sizes in the range of 2 - 4 nm and a SnO{sub 2} (cassiterite) phase. The obtained PtRu/C and PtSn/C electrocatalysts showed similar or superior performance for methanol and ethanol electro-oxidation compared to commercial PtRu/C (E-TEK) and PtSn/C (BASF) electrocatalysts. (author)

  13. Study on LXe system for particle detector. Liquefaction test by pulse tube refrigerator; Ryushi kenshutsuyo ekitai Xenon shisutemu no kenkyu. Parusu kan reitokini yoru ekika

    Energy Technology Data Exchange (ETDEWEB)

    Haruyama, T.; Kasami, K. [High energy Accelerator Research Organization, Tsukuba (Japan)

    1999-11-10

    It is supersensitively used for the particle detection from electrons and that they release the light, that it can deal with fast process, etc. for the high-energy particle which emits liquid Xenon. It recently proposes the experiment which uses large liquid Xenon as a calorimeter in order to detect {gamma}ray of the high energy. It examines the thermal characteristic of liquid Xenon, while this study attempts the optimization in liquefying Xenon by pulse tube refrigerating machine. This time, the following are reported: Introduction of the Xenon gas system for the small-scale liquefaction experiment and experiment near 165K of small pulse tube refrigerating machine on a refrigerating capacity. (NEDO)

  14. Standard performance tests of collectors of solar thermal energy: A selectively coated, flat-plate copper collector with one transparent cover and a tube-to-tube spacing of 3-7/8 inches

    Science.gov (United States)

    1976-01-01

    Basic test results are given of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes, and coolant flow rates. Collector efficiency is correlated in terms of inlet temperature and flux level.

  15. Standardized performance tests of collectors of solar thermal energy: A selectively coated, flat-plate copper collector with one transparent cover and a tube-to-tube spacing of 5 5/8 inches

    Science.gov (United States)

    1976-01-01

    This preliminary data report gives basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficiency is correlated in terms of inlet temperature and flux level.

  16. A comparison of titers of anti-Brucella antibodies of naturally infected and healthy vaccinated cattle by standard tube agglutination test, microtiter plate agglutination test, indirect hemagglutination assay, and indirect enzyme-linked immunosorbent assay

    Directory of Open Access Journals (Sweden)

    Anju Mohan

    2016-07-01

    Full Text Available Aim: We determined the antibody response in cattle naturally infected with brucellosis and normal healthy adult cattle vaccinated during calf hood with strain 19. Materials and Methods: The antibody titers were measured by standard tube agglutination test (STAT, microtiter plate agglutination test (MAT, indirect hemagglutination assay (IHA, and indirect enzyme-linked immunosorbent assay (iELISA as per standard protocols. Results: The mean STAT titers were 1.963±0.345 in infected cattle and 1.200±0.155 in healthy vaccinated cattle. The difference was extremely significant (p<0.0001. The mean MAT titers were 2.244±0.727 in infected cattle and 1.200±0.155 in healthy vaccinated cattle. The difference was very significant (p<0.005. The mean IHA titers in infected cattle were 2.284±0.574, and those in healthy vaccinated cattle were 1.200±0.155. The difference was extremely significant (p=0.0002. However, the difference in mean iELISA titers of infected cattle (1.3678±0.014 and healthy vaccinated cattle (1.367±0.014 was non-significant. The infected animals showed very high titers of agglutinating antibodies compared to the vaccinated animals. However, it cannot be ascertained whether these antibodies are due to vaccine or response to infection. Since the infected animals had been vaccinated earlier, the current infection may suggest that vaccination was unable to induce protective levels of antibody. The heightened antibody response after infection may also indicate a secondary immune response to the antigens common to the vaccine strain and wild Brucella organisms. Conclusion: The brucellosis infected animals showed very high titers of agglutinating antibodies compared to the vaccinated animals.

  17. Direct ethanol fuel cell, CO and ethanol oxidation on core-shell C/Ni-Au-[Pt and (Pt- Ir)] catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, C.A.D.; Tremiliosi-Filho, G. [Universidade de Sao Paulo (IQSC/USP), Sao Carlos, SP (Brazil). Inst. de Quimica], Email: cesaraug@sc.usp.br; Kokoh, K.B.; Coutanceau, C.; Baranton, S. [Universite de Poitiers (France). Lab. de Catalyse en Chimie Organique (LACCO). Equipe Electrocatalyse

    2010-07-01

    In this paper presents to study of the Pt and Pt-Ir monolayer that were deposited on core-shell Ni-Au nanoparticles supported on carbon. Catalysts with the following molar ratios were prepared: Pt and Pt{sub 65}Ir{sub 35}, Pt{sub 75}Ir{sub 2}5, Pt{sub 80}Ir{sub 20} and Pt{sub 85}Ir{sub 15}. The means particle sizes were in the range of 2 - 6 nm for all catalysts. The electrochemical properties examined in the ethanol and CO oxidation by cyclic voltammetry, and In situ IR spectroscopy measurements (SPAIRS) enabled to determine intermediates and reaction products as a function of the metallic compositions of catalysts. All of the catalysts were tested as anodes of a single direct ethanol fuel cell (DEFC) tests in 1.0 M ethanol solution. As a result, higher power densities were obtained with the core-shell particles in comparison to those issued from the commercial catalyst (Pt-ETEK). Thus, the maximum power densities at 90 deg C for the different systems are: (i) commercial C/Pt catalyst (E-TEK): ca. 0.010 W cm{sup -2}, C/Ni-Au-(Pt{sub 85}Ir{sub 15}): ca. 0.013 W cm{sup -2} and C/Ni-Au-Pt: ca. 0.018 W cm{sup -2} (all core-shell systems were normalization by Pt load). As a result, the performance of the core-shell nanoparticles is much better than that produced for the commercial catalyst and the C/Ni-Au-Pt system showed the best performance. (author)

  18. Intercostal drainage tube or intracardiac drainage tube?

    Directory of Open Access Journals (Sweden)

    N Anitha

    2016-01-01

    Full Text Available Although insertion of chest drain tubes is a common medical practice, there are risks associated with this procedure, especially when inexperienced physicians perform it. Wrong insertion of the tube has been known to cause morbidity and occasional mortality. We report a case where the left ventricle was accidentally punctured leading to near-exsanguination. This report is to highlight the need for experienced physicians to supervise the procedure and train the younger physician in the safe performance of the procedure.

  19. The effect of condensate inundation on steam condensation heat transfer to wire-wrapped tubing

    Science.gov (United States)

    Kanakis, G. D.

    1983-06-01

    Steam condensation heat transfer measurements were made in a 5-tube test condenser having an additional perforated tube to simulate up to 30 active tubes. Results were obtained for smooth tubes and roped tubes wrapped with wire. A Sieder-Tate equation was used to correlate the inside heat-transfer coefficient. For smooth tubes, a leading coefficient of 0.029 was found, while it was 0.061 for the roped tubes. The average condensing coefficient measured for 30 smooth tubes was 0.59 times the Nusselt coefficient calculated for the first tube. When the smooth tubes were wrapped with wire, this ratio increased up to 0.86. Further, roped tubes without wire experienced a ratio of 0.63, while roped tubes wrapped with wire resulted in a ratio of 0.86. These preliminary data show that wire-wrapped tubes may lead to a significant reduction in condenser surface area.

  20. Identification of {sup 166}Pt and {sup 167}Pt

    Energy Technology Data Exchange (ETDEWEB)

    Bingham, C.R.; Toth, K.S.; Batchelder, J.C.; Blumenthal, D.J.; Brown, L.T.; Busse, B.C.; Conticchio, L.F.; Davids, C.N.; Davinson, T.; Henderson, D.J.; Irvine, R.J.; Seweryniak, D.; Walters, W.B.; Woods, P.J.; Zimmerman, B.E. [The University of Tennessee, Knoxville, Tennessee 37996 (United States)]|[Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States)]|[Louisiana State University, Baton Rouge, Louisiana 70803 (United States)]|[Argonne National Laboratory, Argonne, Illinois 60439 (United States)]|[Vanderbilt University, Nashville, Tennessee 37235 (United States)]|[Oregon State University, Corvallis, Oregon 97331 (United States)]|[University of Maryland, College Park, Maryland 20742 (United States)]|[Edinburgh University, Edinburgh, EH9 3JZ (United Kingdom)

    1996-07-01

    In a series of {sup 78}Kr bombardments of {sup 92}Mo the new isotopes {sup 166}Pt and {sup 167}Pt were identified via their {alpha}-decay properties. The {alpha}-decay energies and half-lives of these two nuclides are as follows. (1) {sup 166}Pt, {ital E}{sub {alpha}} = 7110(15) keV, {ital T}{sub 1/2} = 0.3(1) ms, and (2) {sup 167}Pt, {ital E}{sub {alpha}} = 6988(10) keV, {ital T}{sub 1/2} = 0.7(2) ms. Also, the half-life of {sup 168}Pt, which was previously unknown, was determined to be 2.0(4) ms. In a separate but concurrent experiment involving {sup 78}Kr + {sup 96}Ru reactions, {sup 170}Pt was made and a half-life of 14.7(5) ms was measured for it; the one published value is 6{sub {minus}2}{sup +5} ms. Results for {sup 162{minus}164}Os contained in the same data sets were also analyzed and by using mother-daughter correlations, the {alpha} branches of {sup 162,163,164}Os were established to be near 100{percent}. {copyright} {ital 1996 The American Physical Society.}

  1. Research on the test-fired precision analysis method of single tube guns by measuring distance-direction error%单管舰炮测量距离方向法试射精度分析方法

    Institute of Scientific and Technical Information of China (English)

    向宏志

    2012-01-01

    单管舰炮与双管舰炮测量距离和方向法试射的方法近似相同,单管舰炮一般以最大发射率连续发射k发炮弹作为1组进行射击,以形成近似双管舰炮齐射的效果.本文充分考虑1组射击中几发弹着的时间间隔所造成的误差,系统地提出了单管舰炮测量距离和方位法试射精度分析的方法和步骤.%Approximately the same single-tube guns with double-barreled guns by measuring distance-direction error,single tube guns generally continuous firing k artillery shells by maximum emission rate as a group of shooters,to form an approximate double-barreled guns salvo. This article fully consider the error caused by the time interval of the shells placement in a group shooting, systematically proposing the methods and procedures of the test-fired precision analysis method of single tube guns by measuring distance-direction error.

  2. Development of Bundle Position-Wise Linear Model for Predicting the Pressure Tube Diametral Creep in CANDU Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Yong [Korea Electric Power Corporation Research Institute, Daejeon (Korea, Republic of); Na, Man Gyun [Chosun University, Gwangju (Korea, Republic of)

    2011-08-15

    Diametral creep of the pressure tube (PT) is one of the principal aging mechanisms governing the heat transfer and hydraulic degradation of a heat transport system. PT diametral creep leads to diametral expansion that affects the thermal hydraulic characteristics of the coolant channels and the critical heat flux. Therefore, it is essential to predict the PT diametral creep in CANDU reactors, which is caused mainly by fast neutron irradiation, reactor coolant temperature and so forth. The currently used PT diametral creep prediction model considers the complex interactions between the effects of temperature and fast neutron flux on the deformation of PT zirconium alloys. The model assumes that long-term steady-state deformation consists of separable, additive components from thermal creep, irradiation creep and irradiation growth. This is a mechanistic model based on measured data. However, this model has high prediction uncertainty. Recently, a statistical error modeling method was developed using plant inspection data from the Bruce B CANDU reactor. The aim of this study was to develop a bundle position-wise linear model (BPLM) to predict PT diametral creep employing previously measured PT diameters and HTS operating conditions. There are twelve bundles in a fuel channel and for each bundle, a linear model was developed by using the dependent variables, such as the fast neutron fluxes and the bundle temperatures. The training data set was selected using the subtractive clustering method. The data of 39 channels that consist of 80 percent of a total of 49 measured channels from Units 2, 3 and 4 were used to develop the BPLM models. The remaining 10 channels' data were used to test the developed BPLM models. The BPLM was optimized by the maximum likelihood estimation method. The developed BPLM to predict PT diametral creep was verified using the operating data gathered from the Units 2,3 and 4 in Korea. Two error components for the BPLM, which are the

  3. SPECIAL PURPOSE SHOCK TUBE for BLAST ASSESSMENT

    Data.gov (United States)

    Federal Laboratory Consortium — This device is a specially designed shock tube for testing fabric samples in a controlled environment. The device determines the appropriate types of sensors to be...

  4. Integrity Assessment of GOH Heater Tube

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Bong Sang; Hong, J. H.; Oh, Y. J.; Yoon, J. H.; Oh, J. M. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1997-08-01

    An assessment of structural integrity of ASTM A312-TP347 GOH heater tube was performed. The surface notches which had been produced during tube manufacturing process were analyzed microscopically. Chemical analysis, hardness tests, tensile tests, and J-Integral fracture resistance tests were carried out to compare the mechanical properties with those of the material specification and also with the other material of the same type. The test results showed the mechanical properties of the GOH tube material are within the specification range. An elastic-plastic fracture mechanics analysis based on the DPFAD method reveals the tube an appropriate safety margin for the normal operation. 13 refs., 5 tabs., 24 figs. (author)

  5. New data on the mobility of Pt emitted from catalytic converters.

    Science.gov (United States)

    Fliegel, Daniel; Berner, Zsolt; Eckhardt, Detlef; Stüben, Doris

    2004-05-01

    The mobility and speciation of Pt was investigated in dust deposited in highway tunnels and in gully sediments. For this, a sequential extraction technique was used in combination with a microwave digestion procedure, followed by detection of Pt with high resolution ICP-MS. A digestion procedure using HNO(3)/HCl/H(2)O(2) was developed and its efficiency tested for environmental materials. Total Pt contents ranged from approximately 100 to 300 microg/kg. The high share of chemically mobile Pt in the tunnel dust (up to about 40%) indicates that Pt is predominantly emitted in a mobile form from the converter. The absence of a mobile fraction in the gully sediment is explained by the elution of Pt by run-off. Except for the mobile and easily mobilised fractions none of the other fractions of the sequential extraction contains Pt, neither in the dust samples nor in the gully sediment.

  6. Pulse Tube Refrigerator

    Science.gov (United States)

    Matsubara, Yoichi

    The pulse tube refrigerator is one of the regenerative cycle refrigerators such as Stirling cycle or Gifford-McMahon cycle which gives the cooling temperature below 150 K down to liquid helium temperature. In 1963, W. E. Gifford invented a simple refrigeration cycle which is composed of compressor, regenerator and simple tube named as pulse tube which gives a similar function of the expander in Stirling or Gifford-McMahon cycle. The thermodynamically performance of this pulse tube refrigerator is inferior to that of other regenerative cycles. In 1984, however, Mikulin and coworkers made a significant advance in pulse tube configuration called as orifice pulse tube. After this, several modifications of the pulse tube hot end configuration have been developed. With those modifications, the thermodynamic performance of the pulse tube refrigerator became the same order to that of Stirling and Gifford-McMahon refrigerator. This article reviews the brief history of the pulse tube refrigerator development in the view point of its thermodynamically efficiency. Simplified theories of the energy flow in the pulse tube have also been described.

  7. 油管悬挂器及下放工具性能鉴定试验方法∗%Performance Identification Test Method for Tubing Hanger and Running Tool

    Institute of Scientific and Technical Information of China (English)

    陈萌; 张来斌; 郑文培; 柴亚军; 段梦兰; 李荣

    2016-01-01

    Performance identification test method for tubing hanger and running tool can guarantee product performance and reliability and it is of great significance on reducing the possibility of potential accidents� Basic concept and objectives of the performance identification test are described on the basis of introduction to structure and function of the tubing hanger and running tool� Based on related standards and characteristics of research ob⁃ject, a performance identification test method is proposed for horizontal christmas tree tubing hanger and running tool� This method specifically divides the test process into test preparation, testing process and summary after tes⁃ting and adds the analysis on fault mode and effect of tested object and fault handling program in the test; it can give specific acceptance or failure criteria for different test objects and test items based on actual conditions and re⁃lated standard regulations� The conclusion is of great significance on guaranteeing operation safety of subsea christ⁃mas tree.%对油管悬挂器及其下放工具进行性能鉴定试验能确保产品的性能和可靠性,对于减小潜在事故发生的可能性具有重要意义。在介绍油管悬挂器及其下放工具结构功能的基础上,阐述了性能鉴定试验的基本概念及目的,参考相关标准并结合所研究对象的特点,提出了一套卧式采油树油管挂及其下放工具的性能鉴定试验方法。该方法将试验过程详细划分为试验准备、试验运行及试验后总结3个阶段,增加了对受试物体的故障模式和影响分析以及试验过程中故障的处理程序等;同时能针对不同的试验对象及试验项目,结合实际情况和相关标准中的规定,给出具体的接受或失效判据。所得结论对保证水下采油树安全运行意义重大。

  8. Film condensation of steam on externally finned horizontal tubes.

    OpenAIRE

    Flook, Frederick A.

    1985-01-01

    Approved for public release; distribution is unlimited Filmwise condensation measurements of steam were made on horizontal finned tubes under vacuum and near-atmospheric conditions. Data were obtained for copper tubes with fins of rectangular, triangular, trapezoidal, and parabolic cross sections, and for a commercially-available finned tube. A stainless steel finned tube was also tested to investigate the effect of thermal conductivity. Maximum enhancements of about 4.8 were obtained...

  9. Development of a ReaxFF potential for Pt-O systems describing the energetics and dynamics of Pt-oxide formation.

    Science.gov (United States)

    Fantauzzi, Donato; Bandlow, Jochen; Sabo, Lehel; Mueller, Jonathan E; van Duin, Adri C T; Jacob, Timo

    2014-11-14

    ReaxFF force field parameters describing Pt-Pt and Pt-O interactions have been developed and tested. The Pt-Pt parameters are shown to accurately account for the chemical nature, atomic structures and other materials properties of bulk platinum phases, low and high-index platinum surfaces and nanoclusters. The Pt-O parameters reliably describe bulk platinum oxides, as well as oxygen adsorption and oxide formation on Pt(111) terraces and the {111} and {100} steps connecting them. Good agreement between the force field and both density functional theory (DFT) calculations and experimental observations is demonstrated in the relative surface free energies of high symmetry Pt-O surface phases as a function of the oxygen chemical potential, making ReaxFF an ideal tool for more detailed investigations of more complex Pt-O surface structures. Validation for its application to studies of the kinetics and dynamics of surface oxide formation in the context of either molecular dynamics (MD) or Monte Carlo simulations are provided in part by a two-part investigation of oxygen diffusion on Pt(111), in which nudged elastic band (NEB) calculations and MD simulations are used to characterize diffusion processes and to determine the relevant diffusion coefficients and barriers. Finally, the power of the ReaxFF reactive force field approach in addressing surface structures well beyond the reach of routine DFT calculations is exhibited in a brief proof-of-concept study of oxygen adsorbate displacement within ordered overlayers.

  10. Screening of electrocatalysts for direct ammonia fuel cell: Ammonia oxidation on PtMe (Me: Ir, Rh, Pd, Ru) and preferentially oriented Pt(1 0 0) nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Vidal-Iglesias, F.J.; Solla-Gullon, J.; Montiel, V.; Feliu, J.M.; Aldaz, A. [Instituto de Electroquimica, Universidad de Alicante, Apartado 99, 03080 Alicante (Spain)

    2007-09-27

    Ammonia has attracted attention as a possible fuel for direct fuel cells since it is easy to handle and to transport as liquid or as concentrated aqueous solution. However, on noble metal electrodes ammonia oxidation is a sluggish reaction and the electrocatalyst needs to be improved for developing efficient ammonia fuel cells. In this work, ammonia electrooxidation reaction on 3-4-nm bimetallic PtMe (Ir, Rh, Pd, Ru) and on preferentially oriented Pt(1 0 0) nanoparticles is reported. PtMe nanoparticles have been prepared by using water-in-oil microemulsions to obtain a narrow size distribution whereas preferentially oriented Pt nanoparticles have been prepared through colloidal routes. Among all the bimetallic samples tested, only Pt{sub 75}Ir{sub 25} and Pt{sub 75}Rh{sub 25} nanoparticles show, at the low potential range, an enhancement of the oxidation density current with respect to the behaviour found for pure platinum nanoparticles prepared by the same method. In addition, two Pt(1 0 0) preferentially oriented nanoparticles of different particle size (4 and 9 nm) have been also studied. These oriented nanoparticles show higher current densities than polycrystalline Pt nanoparticles due to the sensitivity of ammonia oxidation toward the presence of surface sites with square symmetry. The reactivity of the different 4-nm nanoparticles parallels well with that expected from bulk PtMe alloys and Pt single crystal electrodes. (author)

  11. Construction and Test of New Precision Drift-Tube Chambers for Upgrades of the ATLAS Muon Spectrometer in 2016/17

    CERN Document Server

    INSPIRE-00218480; Kortner, O.; Müller, F.; Nowak, S.; Schmidt-Sommerfeld, K.

    2016-01-01

    Small-diameter Muon Drift Tube (sMDT) chambers have been developed for the ATLAS muon detector upgrade. They possess an improved rate capability and a more compact design with respect to the existing chambers, which allows to equip detector regions uninstrument at present. The chamber assembly methods have been optimized for mass production, while the sense wire positioning accuracy is improved to below ten microns. The chambers will be ready for installation in the winter shutdown 2016/17 of the Large Hadron Collider. The design and construction of the new sMDT chambers for ATLAS will be discussed as well as measurements of their precision and performance.

  12. An investigation on SA 213-Tube to SA 387-Tube plate using friction welding process

    Energy Technology Data Exchange (ETDEWEB)

    Rajan, S. Pandia; Kumaraswamidhas, L. A. [Indian Institute of Technology, Jharkhand (India); Kumaran, S. Senthil [RVS School of Engineering and Technology, Tamil Nadu (India); Muthukumaran, S. [National Institute of Technology, Tamil Nadu (India)

    2016-01-15

    Friction welding of tube to tube plate using an external tool (FWTPET) is a relatively newer solid state welding process used for joining tube to tube plate of either similar or dissimilar materials with enhanced mechanical and metallurgical properties. In the present study, FWTPET has been used to weld SA 213 (Grade T12) tube with SA 387 (Grade 22) tube plate. The welded samples are found to have satisfactory joint strength and the Energy dispersive X-ray analysis (EDX), X-ray diffraction (XRD) study showed that inter metallic compound is absent in the weld zone. The different weld joints have been identified and the phase composition is found using EDX and XRD. Microstructures have been analyzed using optical and Scanning electron microscopy (SEM). The mechanical properties such as hardness, compressive shear strength and peel test for different weld conditions are studied and the hardness survey revealed that there is increase in hardness at the weld interface due to grain refinement. The corrosion behavior for different weld conditions have been analyzed and the weld zone is found to have better corrosion resistance due to the influence of the grain refinement after FWTPET welding process. Hence, the present investigation is carried out to study the behavior of friction welded dissimilar joints of SA 213 tube and SA 387 tube plate joints and the results are presented. The present study confirms that a high quality tube to tube plate joint can be achieved using FWTPET process at 1120 rpm.

  13. 螺旋管圈水冷壁鳍片焊缝专用超声检测技术%The Special Ultrasonic Testing Technology for Fins Weld of Spiral Water Cooled Wall Tube

    Institute of Scientific and Technical Information of China (English)

    严祯荣; 陈学东; 罗晓明

    2015-01-01

    针对螺旋管圈水冷壁鳍片焊缝裂纹的产生特性,开发了专用微型超声波检测探头和超声波检测仪器。在刻有近似鳍片裂纹和平底孔的螺旋管圈水冷壁试件上进行了验证性检测试验。在鳍片宽度仅5 mm 的狭长检测空间,通过鳍片单一面耦合,实现了双面鳍片焊缝缺陷检测,能够方便、有效地应用到超超临界锅炉螺旋管圈水冷壁检修环节。%For features of fins crack initiation of spiral water cooled wall tube,a special miniature ultrasonic probe and ultrasonic testing instrument were developed.The confirmatory tests were carried out on specimen of spiral water cooled wall tube,which were engraved with the approximate fins weld crack and flat bottom holes.The confirmatory tests have realized detection of the double fins weld defect in the long and narrow space detection of the only 5 mm fin width,through the fins of the single surface coupling,which can be conveniently and effectively applied to the overhaul of spiral water cooled wall tube of ultra supercritical boiler.

  14. Pt/C Fuel Cell Catalyst Degradation

    DEFF Research Database (Denmark)

    Zana, Alessandro

    This thesis investigates the degradation behavior of Pt/C catalysts under simulated automotive conditions. By using the “tool box” synthesis method the Pt loading has been changed from low to high Pt loadings, therefore permitting to study the role of Pt on the degradation of high surface area (H...

  15. Pt/C Fuel Cell Catalyst Degradation

    DEFF Research Database (Denmark)

    Zana, Alessandro

    This thesis investigates the degradation behavior of Pt/C catalysts under simulated automotive conditions. By using the “tool box” synthesis method the Pt loading has been changed from low to high Pt loadings, therefore permitting to study the role of Pt on the degradation of high surface area (H...

  16. Failure analysis of retired steam generator tubings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hong Pyo; Kim, J. S.; Hwang, S. S. and others

    2005-04-15

    Degradation of steam generator leads to forced outage and extension of outage, which causes increase in repair cost, cost of purchasing replacement power and radiation exposure of workers. Steam generator tube rupture incident occurred in Uljin 4 in 2002, which made public sensitive to nuclear power plant. To keep nuclear energy as a main energy source, integrity of steam generator should be demonstrated. Quantitative relationship between ECT(eddy current test) signal and crack size is needed in assesment of integrity of steam generator in pressurized water reactor. However, it is not fully established for application in industry. Retired steam generator of Kori 1 has many kinds of crack such as circumferential and axial primary water stress corrosion crack and outer diameter stress corrosion crack(ODSCC). So, it can be used in qualifying and improving ECT technology and in condition monitoring assesment for crack detected in ISI(in service inspection). In addition, examination of pulled tube of Kori 1 retired steam generator will give information about effectiveness of non welded sleeving technology which was employed to repair defect tubes and remedial action which was applied to mitigate ODSCC. In this project, hardware such as semi hot lab. for pulled tube examination and modification transportation cask for pulled tube and software such as procedure of transportation of radioactive steam generator tube and non-destructive and destructive examination of pulled tube were established. Non-destructive and destructive examination of pulled tubes from Kori 1 retired steam generator were performed in semi hot lab. Remedial actions applied to Kori 1 retired steam generator, PWSCC trend and bulk water chemistry and crevice chemistry in Kori 1 were evaluated. Electrochemical decontamination technology for pulled tube was developed to reduce radiation exposure and enhance effectiveness of pulled tube examination. Multiparameter algorithm developed at ANL, USA was

  17. Study on the preparation of Pt nanocapsules

    Science.gov (United States)

    Zhang, Yi-fan; Ji, Zhen; Chen, Ke; Liu, Bo-wen; Jia, Cheng-chang; Yang, Shan-wu

    2017-01-01

    Ag@Pt core-shell nanoparticles (Ag@Pt NPs) were prepared by a co-reduction method. Pt nanocapsules with diameters of less than 10 nm were obtained by an electrochemical method. Cyclic voltammetry (CV) scanning was used to cavitate the Ag@Pt NPs, and the morphology, structure, and cavitation conditions were studied. The results indicate that the effective cavitation conditions to obtain Pt nanoparticles from Ag@Pt NPs are a scanning voltage of 0 to 0.8 V and continuous CV scanning over 2 h. This cavitation method is also applicable for the syntheses of Ir, Ru, and Ru-Pt nanocapsules.

  18. Resistive switching of Pt/TiO x /Pt devices fabricated on flexible Parylene-C substrates

    Science.gov (United States)

    Khiat, Ali; Cortese, Simone; Serb, Alexander; Prodromakis, Themistoklis

    2017-01-01

    Pt/TiO x /Pt resistive switching (RS) devices are considered to be amongst the most promising candidates in memristor family and the technology transfer to flexible substrates could open the way to new opportunities for flexible memory implementations. Hence, an important goal is to achieve a fully flexible RS memory technology. Nonetheless, several fabrication challenges are present and must be solved prior to achieving reliable device fabrication and good electronic performances. Here, we propose a fabrication method for the successful transfer of Pt/TiO x /Pt stack onto flexible Parylene-C substrates. The devices were electrically characterised, exhibiting both digital and analogue memory characteristics, which are obtained by proper adjustment of pulsing schemes during tests. This approach could open new application possibilities of these devices in neuromorphic computing, data processing, implantable sensors and bio-compatible neural interfaces.

  19. Safe and adequate placement of nasogastric tubes in the presence of a cuffed tracheostomy tube.

    Science.gov (United States)

    Parmar, A; Macleod, I; McDonald, S; Tierney, P

    2011-09-01

    This case report and review of the literature aims to highlight the importance of the use of a chest radiograph to check the placement of nasogastric tubes after insertion in an awake patient with an inflated cuffed tracheostomy tube regardless of an acidic pH test.

  20. Heated Tube Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Heated Tube Facility at NASA GRC investigates cooling issues by simulating conditions characteristic of rocket engine thrust chambers and high speed airbreathing...

  1. Fuel nozzle tube retention

    Energy Technology Data Exchange (ETDEWEB)

    Cihlar, David William; Melton, Patrick Benedict

    2017-02-28

    A system for retaining a fuel nozzle premix tube includes a retention plate and a premix tube which extends downstream from an outlet of a premix passage defined along an aft side of a fuel plenum body. The premix tube includes an inlet end and a spring support feature which is disposed proximate to the inlet end. The premix tube extends through the retention plate. The spring retention feature is disposed between an aft side of the fuel plenum and the retention plate. The system further includes a spring which extends between the spring retention feature and the retention plate.

  2. Working session 1: Tubing degradation

    Energy Technology Data Exchange (ETDEWEB)

    Kharshafdjian, G. [Atomic Energy of Canada, Mississauga, Ontario (Canada); Turluer, G. [IPSN, Fontenay-aux-Roses (France)

    1997-02-01

    A general introductory overview of the purpose of the group and the general subject area of SG tubing degradation was given by the facilitator. The purpose of the session was described as to {open_quotes}develop conclusions and proposals on regulatory and technical needs required to deal with the issues of SG tubing degradation.{close_quotes} Types, locations and characteristics of tubing degradation in steam generators were briefly reviewed. The well-known synergistic effects of materials, environment, and stress and strain/strain rate, subsequently referred to by the acronym {open_quotes}MESS{close_quotes} by some of the group members, were noted. The element of time (i.e., evolution of these variables with time) was emphasized. It was also suggested that the group might want to consider the related topics of inspection capabilities, operational variables, degradation remedies, and validity of test data, and some background information in these areas was provided. The presentation given by Peter Millet during the Plenary Session was reviewed; Specifically, the chemical aspects and the degradation from the secondary side of the steam generator were noted. The main issues discussed during the October 1995 EPRI meeting on secondary side corrosion were reported, and a listing of the potential SG tube degradations was provided and discussed.

  3. Ferromagnetic Tubes Testing Based Pulsed Remote Field Eddy Current Technique%基于脉冲远场涡流的管道内检测技术

    Institute of Scientific and Technical Information of China (English)

    杨理践; 王赓; 高松巍

    2012-01-01

    针对传统远场涡流检测方法对铁磁性管道内外壁缺陷灵敏度相同,无法有效区分缺陷在管道内壁还是管道外表面的问题,提出了采用具有丰富频率成分的脉冲激励信号取代传统的远场涡流中正弦信号激励的方法.采用小波去噪方法滤除检测数据中的信号噪声;研究了将检测线圈分别置于近场区、过渡区和远场区时的信号时域特性与管壁伤的关系;进行了针对管道管壁内外相同宽度不同深度缺陷的检测试验,结果表明采用脉冲激励作为激励源并综合运用过渡区的检测信号的幅值和过零时间特征能够有效地区分管壁内外全周向的缺陷.%In view of the traditional remote field eddy current technique for ferromagnetic tube having the same sensitivity of inner and outside walls defect,unable to distinguish the defects in the inner wall or in the outer surface,this paper adopt with abundant frequency components of the pulse signal to replace the traditional remote field eddy current sinusoidal excitation signal. Using the methods of wavelet denoising to filter acquired signal and process the data. This paper studied the relationship between the tube wall defects and signal time-domain characteristics when the detector coil was placed in the direct zone, transition zone and remote field zone. Conduct experiments to acquire data about different depth defects in the inside or outside of the walls, the results show that using the pulse signal as excitation source and characteristics about the detect signal amplitude and zero-crossing time can effectively distinguish between the inner and outer circumferential direction tube wall defects.

  4. Alignment methods for the OPERA drift tube detector

    Energy Technology Data Exchange (ETDEWEB)

    Büttner, B.; Ebert, J. [Institut für Experimentalphysik, Universität Hamburg, D-22761 Hamburg (Germany); Ferber, T. [Institut für Experimentalphysik, Universität Hamburg, D-22761 Hamburg (Germany); Deutsches Elektronen Synchrotron (DESY), Notkestr. 85, 22706 Hamburg (Germany); Göllnitz, C., E-mail: christoph.goellnitz@desy.de [Institut für Experimentalphysik, Universität Hamburg, D-22761 Hamburg (Germany); Goloubkov, D. [ITEP Moscow, Bolshaya Cheremushkinskaya 25, 117218, Moscow (Russian Federation); Hagner, C. [Institut für Experimentalphysik, Universität Hamburg, D-22761 Hamburg (Germany); Hierholzer, M. [Institut für Experimentalphysik, Universität Hamburg, D-22761 Hamburg (Germany); Laboratory for High Energy Physics, University of Bern (Switzerland); Hollnagel, A.; Lenkeit, J. [Institut für Experimentalphysik, Universität Hamburg, D-22761 Hamburg (Germany); Rostovtseva, I. [ITEP Moscow, Bolshaya Cheremushkinskaya 25, 117218, Moscow (Russian Federation); Schmidt-Parzefall, W.; Wonsak, B. [Institut für Experimentalphysik, Universität Hamburg, D-22761 Hamburg (Germany); Zaitsev, Y. [ITEP Moscow, Bolshaya Cheremushkinskaya 25, 117218, Moscow (Russian Federation)

    2014-05-21

    The goal of the OPERA experiment is to give the first direct evidence for neutrino oscillations in the channel ν{sub μ}→ν{sub τ}. The OPERA detector is designed to observe the appearance of tau neutrinos in the originally pure muon neutrino CNGS beam. An important part of the magnetic spectrometer is the Precision Tracker (PT), a drift tube detector consisting of 9504 drift tubes. Its main task is the determination of the muon charge and momentum. The alignment strategy for the PT consists of two parts: the hardware measurement by theodolite and the software alignment using long muon tracks. In this paper, the hardware and the software alignment are described, and the track-based alignment methods are explained in detail. Results of the software alignment are presented with a focus on the analysis of cosmic particles.

  5. Steam generator tube failures

    Energy Technology Data Exchange (ETDEWEB)

    MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

    1996-04-01

    A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service.

  6. Double-Side Co-Catalytic Activation of Anodic TiO2 Nanotube Membranes with Sputter-Coated Pt for Photocatalytic H2 Generation from Water/Methanol Mixtures.

    Science.gov (United States)

    Cha, Gihoon; Altomare, Marco; Truong Nguyen, Nhat; Taccardi, Nicola; Lee, Kiyoung; Schmuki, Patrik

    2017-02-01

    Self-standing TiO2 nanotube layers in the form of membranes are fabricated by self-organizing anodization of Ti metal and a potential shock technique. The membranes are then decorated by sputtering different Pt amounts i) only at the top, ii) only at the bottom or iii) at both top and bottom of the tube layers. The Pt-decorated membranes are transferred either in tube top-up or in tube top-down configuration onto FTO slides and are investigated, after crystallization, as photocatalysts for H2 generation using either front or back-side light irradiation. Double-side Pt-decoration of the tube membranes leads to higher H2 generation rates (independently of tube and light-irradiation configuration) compared to membranes decorated at only one side with similar overall Pt amounts. The results suggest that this effect cannot be only ascribed to the overall amount of Pt co-catalyst as such but also to its distribution at both tube extremities. This leads to optimized light absorption and electron diffusion/transfer dynamics: the central part of the membranes acts as light-harvesting zone and electrons therein generated can diffuse towards the Pt/TiO2 active zones (tube extremities) where they can react with the environment and generate H2 . © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Closed End Launch Tube (CELT)

    Science.gov (United States)

    Lueck, Dale E.; Immer, Christopher D.

    2004-02-01

    A small-scale test apparatus has been built and tested for the CELT pneumatic launch assist concept presented at STAIF 2001. The 7.5 cm (3-inch) diameter × 305 M (1000 feet) long system accelerates and pneumatically brakes a 6.35 cm diameter projectile with variable weight (1.5 - 5 Kg). The acceleration and braking tube has been instrumented with optical sensors and pressure transducers at 14 stations to take data throughout the runs. Velocity and pressure profiles for runs with various accelerator pressures and projectile weights are given. This test apparatus can serve as an important experimental tool for verifying this concept.

  8. The effect of condensate inundation on steam condensation heat transfer in a tube bundle

    OpenAIRE

    Brower, Steven K.

    1985-01-01

    Approved for public release; distribution is unlimited Steam-condensation heat-transfer measurements were made using a 5-tube in-line test condenser with an additional perforated tube to simulate up to 30 active tubes. Results were obtained for smooth tubes, wire-wrapped tubes and dropwise-coated tubes. The average outside heat-transfer coefficient for 30 smooth tubes was 0.64 times the Nusselt coefficient for the first tube. A total of eight wirediameter and wire-pitc...

  9. Pt···Pt vs Pt···S contacts between Pt-containing heterobimetallic lantern complexes.

    Science.gov (United States)

    Baddour, Frederick G; Fiedler, Stephanie R; Shores, Matthew P; Bacon, Jeffrey W; Golen, James A; Rheingold, Arnold L; Doerrer, Linda H

    2013-12-01

    A trio of Pt-based heterobimetallic lantern complexes of the form [(py)PtM(SAc)4(py)] (M = Co, 1; Ni, 2; Zn, 3) with unusual octahedral coordination of Pt(II) was prepared from a reaction of [PtM(SAc)4] with excess pyridine. These dipyridine lantern complexes could be converted to monopyridine derivatives with gentle heat to give the series [PtM(SAc)4(py)] (M = Co, 4; Ni, 5; Zn, 6). An additional family of the form [PtM(SAc)4(pyNH2)] (M = Co, 7; Ni, 8; Zn, 9) was synthesized from reaction of [PtM(SAc)4(OH2)] or [PtM(SAc)4] with 4-aminopyridine. Dimethylsulfoxide and N,N-dimethylformamide were also determined to react with [PtM(SAc)4] (M = Co, Ni), respectively, to give [PtCo(SAc)4(DMSO)](DMSO), 10, and [PtNi(SAc)4(DMF)](DMF), 11. Structural and magnetic data for these compounds and those for two other previously published families, [PtM(tba)4(OH2)] and [PtM(SAc)4(L)], L = OH2, pyNO2, are used to divide the structures among three distinct categories based on Pt···Pt and Pt···S distances. In general, the weaker donors H2O and pyNO2 seem to favor metallophilicity and antiferromagnetic coupling between 3d metal centers. When Pt···S interactions are favored over Pt···Pt ones, no coupling is observed and the pKa of the pyridine donor correlates with the interlantern S···S distance. UV-vis-NIR electronic and (1)H NMR spectra provide complementary characterization as well.

  10. Premature temporal theta (PT theta).

    Science.gov (United States)

    Hughes, J R; Fino, J J; Hart, L A

    1987-07-01

    A distinctive pattern called premature temporal theta (PT theta) was studied in 436 infants, ranging in age from 24 to 46 weeks. The pattern is seen in early prematurity, maximizes at 29-31 weeks and then diminishes and disappears near term. Usually the pattern is found independently on both temporal areas, but with a right-sided preference. Patients without PT theta or with a significantly low amount had either neurological or non-neurological (medical) conditions. With age there is a tendency for an increase in frequency and a decrease in amplitude. Five different peaks in the amount of this pattern are seen at approximately every month. Unilateral PT theta tends to be seen in older babies, more often on the right side and with an abnormal EEG. An abnormal EEG is usually associated with a delay in both the appearance and disappearance of this wave form. PT theta is also associated mainly with REM or active sleep. A polynomial rather than an exponential or power function best describes these data with changes of age. PT theta may arise from the inferior temporal gyrus and/or especially the transverse gyrus.

  11. Effect of Pt coverage in Pt-deposited Pd nanostructure electrodes on electrochemical properties

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ah-Reum; Lee, Young-Woo; Kwak, Da-Hee; Park, Kyung-Won [Soongsil University, Seoul (Korea, Republic of)

    2015-06-15

    We have fabricated Pt-deposited Pd electrodes via a two-gun sputtering deposition system by separately operating Pd and Pt target as a function of sputtering time of Pt target. For Pt-deposited Pd electrodes (Pd/Pt-X), Pd were first deposited on the substrates at 20 W for 5min, followed by depositing Pt on the Pd-only electrodes as a function of sputtering time (X=1, 3, 5, 7, and 10min) at 20W on the Pt target. As the sputtering time of Pt target increased, the portion of Pt on the Pd electrodes increased, representing an increased coverage of Pt on the Pd electrodes. The Pd/Pt-7 electrode having an optimized Pt coverage exhibits an excellent electrocatalytic activity for methanol oxidation reaction.

  12. 京枣试管苗染色体稳定性观察%Observation on Chromosomal Stability of Test-tube Seedlings of Jujube Cultivar ‘Jingzao'

    Institute of Scientific and Technical Information of China (English)

    权燕敏; 肖海峰; 陈宗礼

    2013-01-01

    以继代培养20代后经生根培养基生根的京枣试管苗为试验材料,用常规染色体压片和显微观察相结合的方法对根尖进行染色体数目观察,结果显示,京枣试管苗的染色体数目2n=24条的占85%,说明经继代培养的京枣试管苗仍保持遗传稳定性.%The test-tube seedlings of Jujube ‘ Jingzao' after rooting culture and 20 generations of subcultures were used as experiment materials.The methods of traditional chromosome tabletting and microscopic observation were adopted to observe the chromosomal number of root tip cell.The results showed that 85% of the chromosomal number of ‘ Jingzao' was found as 2n =24,which indicated that the test-tube seedlings of ‘ Jingzao' still kept the genetic stability after subculture.

  13. Hologram recording tubes

    Science.gov (United States)

    Rajchman, J. H.

    1973-01-01

    Optical memories allow extremely large numbers of bits to be stored and recalled in a matter of microseconds. Two recording tubes, similar to conventional image-converting tubes, but having a soft-glass surface on which hologram is recorded, do not degrade under repeated hologram read/write cycles.

  14. Synthesis of PtNi Alloy Nanoparticles on Graphene-Based Polymer Nanohybrids for Electrocatalytic Oxidation of Methanol

    Directory of Open Access Journals (Sweden)

    Tung-Yuan Yung

    2016-12-01

    Full Text Available We have successfully produced bimetallic PtNi alloy nanoparticles on poly(diallyldimethylammonium chloride (PDDA-modified graphene nanosheets (PtNi/PDDA-G by the “one-pot” hydrothermal method. The size of PtNi alloy nanoparticles is approximately 2–5 nm. The PDDA-modified graphene nanosheets (PDDA-G provides an anchored site for metal precursors; hence, the PtNi nanoparticles could be easily bond on the PDDA-G substrate. PtNi alloy nanoparticles (2–5 nm display a homogenous alloy phase embedded on the PDDA-G substrate, evaluated by Raman, X-ray diffractometer (XRD, thermal gravity analysis (TGA, electron surface chemical analysis (ESCA, and electron energy loss spectroscopy (EELS. The Pt/Ni ratio of PtNi alloy nanoparticles is ~1.7, examined by the energy dispersive spectroscopy (EDS spectra of transmitting electron microscopy (EDS/TEM spectra and mapping technique. The methanol electro-oxidation of PtNi/PDDA-G was evaluated by cyclic voltammetry (CV in 0.5 M of H2SO4 and 0.5 M of CH3OH. Compared to Pt on carbon nanoparticles (Pt/C and Pt on Graphene (Pt/G, the PtNi/PDDA-G exhibits the optimal electrochemical surface area (ECSA, methanol oxidation reaction (MOR activity, and durability by chrono amperometry (CA test, which can be a candidate for MOR in the electro-catalysis of direct methanol fuel cells (DMFC.

  15. Shaking table test study on shear walls with concrete-filled steel tube columns and embedded steel-plate%钢管混凝土边框内藏钢板剪力墙振动台试验研究

    Institute of Scientific and Technical Information of China (English)

    曹万林; 王尧鸿; 董宏英; 张建伟

    2011-01-01

    进行了4个钢板剪力墙模型的模拟地震振动台试验,其中2个模型为钢管混凝土边框钢板剪力墙,高宽比分别为1.7和3.2;2个模型为钢管混凝土边框内藏钢板剪力墙,高宽比分别为1.7和3.2.试验中输人Taft地震动,测试了各试件在不同峰值加速度下的时程地震反应和动力特性,分析了剪力墙的破坏特征.研究表明:钢管混凝土边框内藏钢板混凝土剪力墙与钢管混凝土边框钢板剪力墙相比,地震反应明显较小,抗震性能显著提高.%Four steel-plate shear walls were tested on the shaking table. Two of the walls are steel-plate shear walls with concrete-filled steel tube columns and the other two are composite shear walls with concrete-filled steel tube columns and embedded steel-plate. The ratio of height to width is 1.7 and 3.2 respectively. The Taft seismic ground motion was input in the shaking table test. Based on the experiment, dynamic characters, dynamic responses and failure modes of the four specimens in different seismic peak accelerations are contrastively analyzed. The results show that compared with the steel-plate shear walls with concrete-filled steel tube columns, shear walls with concrete-filled steel tube columns and embedded steel-plate have the following characteristics: the dynamic responses are significantly reduced, the seismic behavior is significantly improved.

  16. Turbulent flow in longitudinally finned tubes

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, D.P.; Hirsa, A.; Jensen, M.K. [Rensselaer Polytechnic Inst., Troy, NY (United States). Dept. of Mechanical Engineering, Aeronautical Engineering and Mechanics

    1996-09-01

    An experimental investigation of fully developed, steady, turbulent flow in longitudinally finned tubes has been performed. A two-channel, four-beam, laser-Doppler velocimeter was used to measure velocity profiles and turbulent statistics of air flow seeded with titanium dioxide particles. Mean velocities in axial, radial, and circumferential directions were measured over the tube cross sections and pressure drop in the tubes was measured at six stations along the test section length in order to calculate the fully developed friction factor. Four experimental tube geometries were studied: one smooth tube; two 8-finned tubes (fin height-to-radius ratios of 0.333 and 0.167), and one 16-finned tube (fin height-to-radius ratio of 0.167); detailed measurements were taken at air flow rates corresponding to Reynolds numbers of approximately 5,000, 25,000, and 50,000. Friction factor data were compared to literature results and showed good agreement for both smooth and finned tubes. The wall shear stress distribution varied significantly with reynolds number, particularly for Reynolds numbers of 25,000 and below. Maximum wall shear stress was found at the fin tip and minimum at the fin root. Four secondary flow cells were detected per fin (one in each interfin spacing and one in each core region for each fin); secondary flows were found to be small in comparison to the mean axial flow and relative magnitudes were unaffected by axial flow rate at Reynolds numbers above 25,000. The fluctuating velocities had a structure similar to that of the smooth tube in the core region while the turbulence in the interfin region was greatly reduced. The principal, primary shear stress distribution differed considerably from that of the smooth tube, particularly in the interfin region, and the orientation was found to be approximately in the same direction as the gradient of the mean axial velocity, supporting the use of an eddy viscosity formulation in turbulence modeling.

  17. Evacuated-tube solar collector--performance evaluation

    Science.gov (United States)

    1980-01-01

    Report gives thermal performance test procedures and results for commercially produced, water-filled, 8-tube collectors. Tests include efficiency, time constant for temperature drop after solar flux is cut, change in efficiency as function of sun angle, and test to see if tubes break when filled with hot water.

  18. Molybdenum Tube Characterization report

    Energy Technology Data Exchange (ETDEWEB)

    Beaux II, Miles Frank [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Usov, Igor Olegovich [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-02-07

    Chemical vapor deposition (CVD) techniques have been utilized to produce free-standing molybdenum tubes with the end goal of nuclear fuel clad applications. In order to produce tubes with properties desirable for this application, deposition rates were lowered requiring long deposition durations on the order of 50 hours. Standard CVD methods as well as fluidized-bed CVD (FBCVD) methods were applied towards these objectives. Characterization of the tubes produced in this manner revealed material suitable for fuel clad applications, but lacking necessary uniformity across the length of the tubes. The production of freestanding Mo tubes that possess the desired properties across their entire length represents an engineering challenge that can be overcome in a next iteration of the deposition system.

  19. Categorising YouTube

    DEFF Research Database (Denmark)

    Simonsen, Thomas Mosebo

    2011-01-01

    This article provides a genre analytical approach to creating a typology of the User Generated Content (UGC) of YouTube. The article investigates the construction of navigation processes on the YouTube website. It suggests a pragmatic genre approach that is expanded through a focus on YouTube’s...... technological affordances. Through an analysis of the different pragmatic contexts of YouTube, it is argued that a taxonomic understanding of YouTube must be analysed in regards to the vacillation of a user-driven bottom-up folksonomy and a hierarchical browsing system that emphasises a culture of competition...... and which favours the already popular content of YouTube. With this taxonomic approach, the UGC videos are registered and analysed in terms of empirically based observations. The article identifies various UGC categories and their principal characteristics. Furthermore, general tendencies of the UGC within...

  20. Wavy tube heat pumping

    Energy Technology Data Exchange (ETDEWEB)

    Haldeman, C. W.

    1985-12-03

    A PVC conduit about 4'' in diameter and a little more than 40 feet long is adapted for being seated in a hole in the earth and surrounds a coaxial copper tube along its length that carries Freon between a heat pump and a distributor at the bottom. A number of wavy conducting tubes located between the central conducting tube and the wall of the conduit interconnect the distributor with a Freon distributor at the top arranged for connection to the heat pump. The wavy conducting tubing is made by passing straight soft copper tubing between a pair of like opposed meshing gears each having four convex points in space quadrature separated by four convex recesses with the radius of curvature of each point slightly less than that of each concave recess.

  1. Electron transport in a Pt-CO-Pt nanocontact: Density functional theory calculations

    DEFF Research Database (Denmark)

    Strange, Mikkel; Thygesen, Kristian Sommer; Jacobsen, Karsten Wedel

    2006-01-01

    We have performed first-principles calculations for the mechanic and electric properties of pure Pt nanocontacts and a Pt contact with a single CO molecule adsorbed. For the pure Pt contacts we see a clear difference between point contacts and short chains in good agreement with experiments. We i...... of the transmission function for the Pt-CO-Pt contact, and show that the conductance is largely determined by the local d band at the Pt apex atoms....

  2. Definition of the minimum longitude of insert in the rebuilding of Charpy test tubes for surveillance and life extension of vessels in Mexico; Definicion de la longitud minima de inserto en la reconstitucion de probetas Charpy para vigilancia y extension de vida de vasijas en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Romero C, J.; Hernandez C, R.; Rocamontes A, M., E-mail: jesus.romero@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2011-11-15

    In the National Institute of Nuclear Research (Mexico) a welding system for the rebuilding of Charpy test tubes has been developed, automated, qualified and used for the surveillance of the mechanical properties (mainly embrittlement) of the vessel. This system uses the halves of the rehearsed Charpy test tubes of the surveillance capsules extracted of the reactors, to obtain, of a rehearsed test tube, two reconstituted test tubes. This rebuilding process is used so much in the surveillance program like in the potential extension of the operation license of the vessel. To the halves of Charpy test tubes that have been removed the deformed part by machine are called -insert- and in a very general way the rebuilding consists in weld with the welding process -Stud Welding- two metallic implants in the ends of the insert, to obtain a reconstituted test tube. The main characteristic of this welding are the achieved small dimensions, so much of the areas welded as of the areas affected by the heat. The applicable normative settles down that the minim longitude of the insert for the welding process by Stud Welding it should be of 18 mm, however according to the same normative this longitude can diminish if is demonstrated analytic or experimentally that the central volume of 1 cm{sup 3} in the insert is not affected. In this work the measurement of the temperature profiles to different distances of the welding interface is presented, defining an equation for the maximum temperatures reached in function of the distance, on the other hand the real longitude affected in the test tube by means of metallography is determined and this way the minimum longitude of the insert for this developed rebuilding system was determined. (Author)

  3. What Are Neural Tube Defects?

    Science.gov (United States)

    ... NICHD Research Information Clinical Trials Resources and Publications Neural Tube Defects (NTDs): Condition Information Skip sharing on social media links Share this: Page Content What are neural tube defects? Neural (pronounced NOOR-uhl ) tube defects are ...

  4. Conducting the Safety Diagnosis of Furnace Tubes by Non-destructive Tests%通过微观组织分析进行在役炉管的安全诊断

    Institute of Scientific and Technical Information of China (English)

    喻红梅; 涂善东; 张礼敬

    2001-01-01

    在役炉管可以通过外观检查、表面硬度测试、表面金相分析等手段确定炉管各部位的损伤程度,炉管的失效往往发生在炉管损伤最严重的局部,因此,炉管的安全诊断应考虑不同位置的炉管组织性能的差异。%The safety diagnosis of furnace tubes was conducted by non-destructive tests such as visual inspection,surface hardness testing and surface metallographical examinaions.The furnace tube′s failure is happened in a local damage.So the safety assessment thinks related with different local positions

  5. Electrodeposited CoPt and FePt alloys nanowires

    Energy Technology Data Exchange (ETDEWEB)

    Cagnon, L. [Laboratoire de Cristallographie, CNRS, BP 166, 38042 Grenoble cedex 9 (France)]. E-mail: laurent.cagnon@grenoble.cnrs.fr; Dahmane, Y. [Laboratoire Louis Neel, CNRS, BP 166, 38042 Grenoble cedex 9 (France); Laboratoire de Materiaux, Electrochimie et Corrosion, BP 17, 15000 Tizi-Ouzou (Algeria); Voiron, J. [Laboratoire Louis Neel, CNRS, BP 166, 38042 Grenoble cedex 9 (France); Pairis, S. [Laboratoire de Cristallographie, CNRS, BP 166, 38042 Grenoble cedex 9 (France); Bacia, M. [Laboratoire de Cristallographie, CNRS, BP 166, 38042 Grenoble cedex 9 (France); Ortega, L. [Laboratoire de Cristallographie, CNRS, BP 166, 38042 Grenoble cedex 9 (France); Benbrahim, N. [Laboratoire de Materiaux, Electrochimie et Corrosion, BP 17, 15000 Tizi-Ouzou (Algeria); Kadri, A. [Laboratoire de Materiaux, Electrochimie et Corrosion, BP 17, 15000 Tizi-Ouzou (Algeria)

    2007-03-15

    We have investigated CoPt and FePt alloys with the face centered tetragonal phase L10, which present very large magnetocrystalline anisotropy. Equiatomic CoPt nanowires exhibiting large coercive fields up to 1.1 T have been successfully prepared by electrodeposition into nanopores of commercial and home-made alumina membranes from a very simple electrolyte. The as-deposited material has the FCC structure with soft magnetic properties. An annealing treatment at 700 deg. C is crucial to transform this phase into the L1{sub 0} phase, which presents hard magnetic properties. Nanowires of annealed samples consist of small grains around 20 nm, with their c axes randomly distributed. The coercivity does not depend on the morphology and porosity of the two types of membranes but only on the deposited material elaborated with the appropriate thermal annealing process. Our preliminary results with FePt alloy indicate a more complicated system since the as-deposited material shows no magnetization. Magnetism appears only after annealing at 700-750 deg. C. Coercivity up to 0.85 T has been obtained at room temperature but with inhomogeneous phase composition. To achieve a single hard phase L1{sub 0}, it is essential to get for the as-deposited sample the equiatomic composition and then to employ the suitable annealing parameters (temperature and time) to change the whole FCC phase into the FCT ordered L1{sub 0} phase.

  6. Techno-economic analysis of single U-tube and double U-tube heat exchangers in Chongqing area

    Institute of Scientific and Technical Information of China (English)

    王勇; 郭凯生; 田荣; 韩传璞; 赖道新; 徐峰

    2009-01-01

    On the basis of practical projects in Chongqing,the thermal performance of heat exchangers (single U-tube type and double U-tube type) of the ground-source heat pump (GSHP) system in the hot summer was obtained and analyzed. The data obtained from test could match with the result deduced from theoretical calculation. From the test results,the cooling capacity of double U-tube is 1.6 times that of single U-tube. Taking cost per depth per watt Clq as the evaluation standard,Clq of single U-tube is 4.69 RMB$/W,and Clq of double U-tube is 3.14 RMB$/W. The double U-tube heat exchangers usage should be prioritized.

  7. Comparative study of 3 screening tests, ExplorerO test, PremiOTest2 microbiological tube tests and a multi-sulphonamides ELISA kit, for the detection of antimicrobial and sulphonamide residues in eggs

    OpenAIRE

    2009-01-01

    Abstract The screening of antimicrobial residues in eggs is especially an important subject. Three different commercial kits for the screening of sulphonamides and other antimicrobials in eggs have been validated in accordance with the decision 2002/657/EC (EC 2002): one ELISA kit multi-sulphonamides (from RAISIO Diagnostics) and 2 microbiological tests (PremiOTest from DSM and ExplorerO kit from Zeu-Inmunotec). The specificity was very satisfactory for all kits (false posit...

  8. Ab-initio study of the coadsorption of Li and H on Pt(001), Pt(110) and Pt(111) surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Saad, Farida [Laboratoire de Physique et Chimie Quantique, Faculte des Sciences, Universite Mouloud Mammeri, 15000 Tizi-Ouzou (Algeria); Zemirli, Mourad, E-mail: zemirlimourad@mail.ummto.dz [Laboratoire de Physique et Chimie Quantique, Faculte des Sciences, Universite Mouloud Mammeri, 15000 Tizi-Ouzou (Algeria); Benakki, Mouloud; Bouarab, Said [Laboratoire de Physique et Chimie Quantique, Faculte des Sciences, Universite Mouloud Mammeri, 15000 Tizi-Ouzou (Algeria)

    2012-02-15

    The coadsorption of Li and H atoms on Pt(001), Pt(110) and Pt(111) surfaces is studied using density functional theory with generalised gradient approximation. In all calculations Li, H and the two topmost layers of the metal were allowed to relax. At coverage of 0.25 mono-layer in a p(2 Multiplication-Sign 2) unit cell, lithium adsorption at the hollow site for the three surfaces is favoured over top and bridge sites. The most favoured adsorption sites for H atom on the Pt(001) and Pt(110) surfaces are the top and bridge sites, while on Pt(111) surface the fcc site appears to be slightly favoured over the hcp site. The coadsorption of Li and atomic hydrogen shows that the interaction between the two adsorbates is stabilising when they are far from each other. The analysis of Li, H and Pt local density of states shows that Li strongly interacts with the Pt surfaces.

  9. Accuracy in HIV Rapid Testing among Laboratory and Non-laboratory Personnel in Zambia: Observations from the National HIV Proficiency Testing System.

    Directory of Open Access Journals (Sweden)

    Sheila Mwangala

    Full Text Available Despite rapid task-shifting and scale-up of HIV testing services in high HIV prevalence countries, studies evaluating accuracy remain limited. This study aimed to assess overall accuracy level and factors associated with accuracy in HIV rapid testing in Zambia.Accuracy was investigated among rural and urban HIV testing sites participating in two annual national HIV proficiency testing (PT exercises conducted in 2009 (n = 282 sites and 2010 (n = 488 sites. Testers included lay counselors, nurses, laboratory personnel and others. PT panels of five dry tube specimens (DTS were issued to testing sites by the national reference laboratory (NRL. Site accuracy level was assessed by comparison of reported results to the expected results. Non-parametric rank tests and multiple linear regression models were used to assess variation in accuracy between PT cycles and between tester groups, and to examine factors associated with accuracy respectively.Overall accuracy level was 93.1% (95% CI: 91.2-94.9 in 2009 and 96.9% (95% CI: 96.1-97.8 in 2010. Differences in accuracy were seen between the tester groups in 2009 with laboratory personnel being more accurate than non-laboratory personnel, while in 2010 no differences were seen. In both PT exercises, lay counselors and nurses had more difficulties interpreting results, with more occurrences of false-negative, false-positive and indeterminate results. Having received the standard HIV rapid testing training and adherence to the national HIV testing algorithm were positively associated with accuracy.The study showed an improvement in tester group and overall accuracy from the first PT exercise to the next. Average number of incorrect test results per 1000 tests performed was reduced from 69 to 31. Further improvement is needed, however, and the national HIV proficiency testing system seems to be an important tool in this regard, which should be continued and needs to be urgently strengthened.

  10. Myringotomy versus ventilation tubes in secretory otitis media: eardrum pathology, hearing, and eustachian tube function 25 years after treatment

    DEFF Research Database (Denmark)

    Caye-Thomasen, P.; Stangerup, S.E.; Jorgensen, G.

    2008-01-01

    . At the last evaluation, the eustachian tube function was evaluated by the 9-step test. RESULTS: 1) Myringosclerosis and late atrophy were more prevalent in tube ears. 2) Prevalence of eardrum retraction decreased over time, whereas that of sclerosis remained unchanged in tube ears and increased in myringotomy...... ears. 3) Prevalence of atrophy increased over time in tube ears. 4) Extension of myringosclerosis increased, whereas that of atrophy and tensa retraction decreased over time, regardless of treatment. 5) Hearing was better in the tube ear during, but not after treatment. 6) Tympanometric findings were...

  11. Applicable methods for NDT of tubes

    Energy Technology Data Exchange (ETDEWEB)

    Pitkaenen, J.; Lipponen, A.; Kauppinen, P. [VTT Industrial Systems Espoo (Finland)

    2004-05-01

    For inside inspection of tubes, eddy current testing (ET) and internal rotating ultrasonic inspection (IRIS) are mainly used at the moment. Special eddy current method, remote field technique (RFEC) is being used to some extent, but normally only for ferritic tubes. This paper presents a review of techniques that can be used for internal inspections of tubes in boilers, heat exchangers and steam generators. Material affects the choice of the method, considering given defect type and detectability with the selected technique. In general ET methods are used for inspection of non- ferromagnetic tubes and IRIS and RFEC methods for inspection of ferromagnetic tubes. New techniques have been introduced, to determine the tube condition accurately. One of the developed techniques is for instance inspection of the internal surface by combination of dye penetrant and optical laser inspection. New applications of ultrasonic techniques include defect detection and characterisation by tip diffraction echoes, defect analysis by echo dynamics and the TOFD-technique for defect sizing. Ultrasonic guided waves have a great potential to increase inspection speed for defect detection, although sizing is still under development. For inspection of ferromagnetic tubes, a method based on magnetic flux leakage has been used. In addition to the basic techniques visualisation of the measured data is one of the. key factors for improved exploitation of the inspection results. (orig.)

  12. 医用诊断X光机管电流测试系统的设计与实现%Design and Implementation of Medical Diagnostic X -ray Machine's Tube Current Testing System

    Institute of Scientific and Technical Information of China (English)

    黄平; 方方; 刘志宏

    2011-01-01

    As an important parameter, Medical X-ray tube current control the X - ray intensity, which has been included in the JJG 744 - 2004 " Medical Diagnostic X-ray radiation sources" in the state verification procedures. With the continuous development of the digital diagnosis and treatment, traditional ammeter is not a-ble to measure the X - ray tube current and exposure time accuratly, in order to ensure safety and reliable operation of Medical X - ray machine , improve the corresponding level of digital detection, so designing a verifaction of non - intrusive system of tube current, which include FPGA combination of high speed ADC digital sampling technology, current transformers and Bluetooth technology. The system has obvious advantages on the diversification of measured parameters and the accuracy of data analysising, has more in line with the characteristics of tube current. At the same time with high accuracy and good repeatability, the system meet national requirements of testing procedures.%X光机管电流作为控制X射线强度的重要参数,已被包含在JJG 744 - 2004《医用诊断X射线辐射源》国家计量检定规程中.随着数字诊断治疗水平的不断发展,传统电流表已不能准确测量X光机管电流与曝光时间,为了保障医用X光机安全可靠运行,提高与之相应的数字化检测水平,设计验证了一套包含高速ADC与FPGA结合的数字化采样技术、电流互感器与蓝牙技术的非介入式管电流测试系统,该系统在测量参数多样化、数据分析准确性方面优势明显,较符合X光机管电流特征,具有测量精度高、重复性好等优点,满足国家检定规程要求.

  13. A novel closed-tube method based on high resolution melting (HRM) analysis for authenticity testing and quantitative detection in Greek PDO Feta cheese.

    Science.gov (United States)

    Ganopoulos, Ioannis; Sakaridis, Ioannis; Argiriou, Anagnostis; Madesis, Panagiotis; Tsaftaris, Athanasios

    2013-11-15

    Animal species identification of milk and dairy products has received increasing attention concerning food composition, traceability, allergic pathologies and accurate consumer information. Here we sought to develop an easy to use and robust method for species identification in cheese with emphasis on an authenticity control of PDO Feta cheese products. We used specific mitochondrial DNA regions coupled with high resolution melting (HRM) a closed-tube method allowing us to detect bovine, ovine and caprine species and authenticate Greek PDO Feta cheese. The primers successfully amplified DNA isolated from milk and cheese and showed a high degree of specificity. HRM was proven capable of accurately identifying the presence of bovine milk (not allowed in Feta) down to 0.1% and also of quantifying the ratio of sheep to goat milk mixture in different Feta cheese commercial products. In conclusion, HRM analysis can be a faster, with higher resolution and a more cost effective alternative method to authenticate milk and dairy products including PDO Feta cheese and to quantitatively detect its sheep milk adulterations.

  14. Test Study on Monitoring and Evaluation of Grouting Effect in the Immersed Tube Tunnel%沉管隧道注浆效果监测与评价的试验研究

    Institute of Scientific and Technical Information of China (English)

    沈永芳; 黄醒春

    2013-01-01

    为了探索沉管隧道管底注浆效果的监测方法和评价体系,在国内率先采用探地雷达和数字地震仪对舟山沈家门港海底隧道模型的注浆基础进行了测试研究.通过在注浆前、注浆过程中以及注浆完成2小时后所进行的现场检测,将采集到雷达波形和面波波形与模型中预先设置的观察窗现场观察的结果进行对比,确定注浆前、注浆过程中、注浆完成后三个阶段的典型波形,以判别和评价沉管隧道管底注浆基础效果.试验结果表明,探地雷达结合面波法的监测方法能作为在管底注浆施工时的停止注浆条件之一,可满足沉管隧道现场施工时管底注浆基础效果的监测和评价,进而可为沉管隧道的工程设计方案提供依据.%In order to explore the monitoring methods and evaluation system of the immersed tube tunnel grouting effect,the grouting foundation of Shenjiamen port cross-harbour tunnel model has been tested firstly using ground penetrating radar and digital seismograph in Zhoushan,Zhejiang,China.By field testing before grouting,during grouting process and 2 hours after grouting,the collected waveforms by ground penetrating radar and surface wave have been compared with the results of field observations in pre-set viewing window.The typical waveforms of three phases (before grouting,in grouting process and after grouting) would be determined,which have been to differentiate and evaluate the foundation grouting effect of the immersed tube tunnel.The test results showed that the monitoring method combining ground penetrating radar and surface wave could be used as one of the conditions to stop grouting in the construction of the tube bottom and could meet the monitoring and evaluation of the foundation grouting effect in the immersed tube tunnel construction site.This method will also provide the basis for engineering design programs of the immersed tube tunnel.

  15. Catalytic and DRIFTS study of the WGS reaction on Pt-based catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Vignatti, Ch.; Avila, M.S.; Apesteguia, C.R.; Garetto, T.F. [Catalysis Science and Engineering Research Group (GICIC), Instituto de Investigaciones en Catalisis y Petroquimica - INCAPE - (UNL-CONICET), Santiago del Estero 2654, 3000 Santa Fe (Argentina)

    2010-07-15

    The water-gas shift (WGS) activity of Pt/SiO{sub 2}, Pt/CeO{sub 2} and Pt/TiO{sub 2} catalysts was studied by in-situ diffuse reflection infrared Fourier transform spectroscopy (DRIFTS). Samples contained a similar amount of Pt, between 0.34 and 0.50%, and were characterized by employing a variety of physical and spectroscopic techniques. The catalyst activities were evaluated through both CO conversion versus temperature and CO conversion versus time tests. The DRIFTS spectra were obtained on stream during the WGS reaction at increasing temperatures, from 303 to 573 K. Reduced ceria was the only active support and promoted the WGS reaction on surface bridging OH groups that react with CO to form formate intermediates. Pt/SiO{sub 2} was more active than CeO{sub 2} and catalyzed the WGS reaction through a monofunctional redox mechanism on metallic Pt sites. The CO conversion turnover rate was more than one order of magnitude greater on Pt/CeO{sub 2} than on Pt/SiO{sub 2} showing that the reaction proceeds faster via a bifunctional metal-support mechanism. Platinum on Pt/CeO{sub 2} increased the concentration of OH groups by increasing the ceria reduction extent and also provided a faster pathway for the formation of formate intermediates in comparison to CeO{sub 2} support. Pt/TiO{sub 2} catalysts were clearly more active than Pt/CeO{sub 2}. The WGS reaction on Pt/TiO{sub 2} was catalyzed via a bifunctional metal-support mechanism, probably involving the activation of CO and water on the metal and the support, respectively. The role of platinum on Pt/TiO{sub 2} was critical for promoting the reduction of Ti{sup 4+} ions to Ti{sup 3+} which creates oxygen vacancies in the support to efficiently activate water. (author)

  16. Cyclic-Oxidation Behavior of Multilayered Pt/Ru-Modified Aluminide Coating

    Institute of Scientific and Technical Information of China (English)

    Yingxue Song; Hideyuki Murakami; Chungen Zhou

    2011-01-01

    Multilayered Pt/Ru modified aluminide coating for thermal barrier coating (TBC) systems has been investigated. 2 μm Pt+2μm Ru+2 μm Pt was first deposited on nickel-base superalloy DZ125 by electrodeposition, and then the coating was treated by annealing and a conventional pack-cementation aluminizing process. The cyclic oxidation tests were carried out at 1423 K in air. It was found that the thermal cyclic oxidation resistance of Pt/Ru-modified aluminide coating was comparable to that of Pt-modified aluminide coating, which was much better than simply aluminized DZ125. The addition of Ru to Pt-modified aluminide coating increased the resistance to rumpling. The microstructures and phase constitutions of the coating before and after oxidation were investigated.

  17. PtRu/C Electrocatalysts Prepared Using Gamma and Electron Beam Irradiation for Methanol Electrooxidation

    Directory of Open Access Journals (Sweden)

    Dionisio F. Silva

    2012-01-01

    Full Text Available PtRu/C electrocatalysts (carbon-supported PtRu nanoparticles were prepared in a single step submitting water/2-propanol mixtures containing Pt(IV and Ru(III ions and the carbon support to gamma and electron beam irradiation. The electrocatalysts were characterized by energy dispersive X-ray analysis (EDX, X-ray diffraction (XRD, transmission electron microscopy (TEM, and cyclic voltammetry and tested for methanol electrooxidation. PtRu/C electrocatalyst can be prepared in few minutes using high dose rate electron beam irradiation while using low dose rate gamma irradiation some hours were necessary to prepare it. The obtained materials showed the face-centered cubic (fcc structure of Pt and Pt alloys with average nanoparticle sizes of around 3 nm. The material prepared using electron beam irradiation was more active for methanol electrooxidation than the material prepared using gamma irradiation.

  18. Isolated Fallopian Tube Torsion

    Directory of Open Access Journals (Sweden)

    S. Kardakis

    2013-01-01

    Full Text Available Isolated torsion of the Fallopian tube is a rare gynecological cause of acute lower abdominal pain, and diagnosis is difficult. There are no pathognomonic symptoms; clinical, imaging, or laboratory findings. A preoperative ultrasound showing tubular adnexal masses of heterogeneous echogenicity with cystic component is often present. Diagnosis can rarely be made before operation, and laparoscopy is necessary to establish the diagnosis. Unfortunately, surgery often is performed too late for tube conservation. Isolated Fallopian tube torsion should be suspected in case of acute pelvic pain, and prompt intervention is necessary.

  19. Electrochemical oxidation of methanol on Pt/(RuxSn1-xO2 nanocatalyst

    Directory of Open Access Journals (Sweden)

    Krstajić Mila N.

    2013-01-01

    Full Text Available The Ru-doped SnO2 powder, (RuxSn1-xO2, with the Sn:Ru atomic ratio of 9:1 was synthesized and used as a support for Pt nanoparticles (30 mass% loading. The (RuxSn1-xO2 support and Pt/(RuxSn1-xO2 catalyst were characterized by X-ray diffraction, energy dispersive X-ray spectroscopy and transmission electron microscopy (TEM. (RuxSn1-xO2 was found to be two-phase material consisting of probably solid solution of RuO2 in SnO2 and pure RuO2. The average Pt particle size determined by TEM was 5.3 nm. Cyclic voltammetry of Pt/(RuxSn1-xO2 indicated good conductivity of the sup-port and displayed usual features of Pt. The results of the electrochemical oxidation of COads and methanol on Pt/(RuxSn1-xO2 were compared with those on commercial Pt/C and PtRu/C catalysts. Oxidation of COads on Pt/(RuxSn1-xO2 starts at less positive potentials than on PtRu/C and Pt/C. Potentiodynamic polarization curves and chronoamperometric curves of methanol oxidation indicated higher initial activity of Pt/(RuxSn1-xO2 catalyst compared to PtRu/C, but also a greater loss in the current density over time. Potentiodynamic stability test of the catalysts revealed that deactivation of the Pt/(RuxSn1-xO2 and Pt/C was primarily caused by the poisoning of Pt surface by the methanol oxidation residues, which mostly occurred during the first potential cycle. In the case of PtRu/C the poisoning of the surface was minor and deactivation was caused by the PtRu surface area loss. [Projekat Ministarstva nauke Republike Srbije, br. ON-172054

  20. The significance of vaterite occurrence in tube blocking tests using Na-K-Ca-Cl-HCO{sub 3}-H{sub 2}O brines at 120degC

    Energy Technology Data Exchange (ETDEWEB)

    Mulshaw, Sean [Imperial Coll., TH Huxley School of Environment, Earth Science and Engineering, London (United Kingdom); Locardel, Beatrice [BP Exploration, Sunbury-on-Thames (United Kingdom)

    1999-02-01

    CaCO{sub 3} scaling at 120degC and formation water flow along well tubing during production, is modelled using tube blocking experiments utilising Na-K-Ca{sub C}l-HCO{sub 3}-H{sub 2}O brines. All tests produced scale assemblages dominated by aragonite, vaterite ({<=}45%) and some calcite. Vaterite is a rare form of CaCO{sub 3} so its occurrence is particularly significant. Vaterite precipitation was initiated by rapid CaCO{sub 3} supersaturation, driven by lower CaCO{sub 3} solubility at 120degC, combined with high relative concentrations of HCO{sup -}{sub 3} in the brine (HCO{sup -}{sub 3}/Ca=12). Few accounts of oil field scaling focus on carbonate mineralogy. The formation of mixed-carbonates in this study emphasizes that more attention should be paid to mineralogical characterisation of carbonate scale in relation to production conditions, formation water chemistry and inhibitor selection. This could lead to improvements in both scale prediction and inhibitor efficiency. (Author)

  1. L Tube Gravity Feed Simulation Test Based on Coarse Tailings Cemented Filling%基于粗尾砂胶结充填的L管自流输送模拟试验

    Institute of Scientific and Technical Information of China (English)

    郭江龙; 白金

    2015-01-01

    Through simulation test of the gravity feed resistance of the L tube cemented filled with coarse tailings, it is proved that to add some MSP into the filling slurry can greatly improve its suspension property and liquidity, thus reducing the wear to the tube, and effectively solving the layering, separation and riffling phenomenon. So it has good popularization prospect in mine industry.%通过对某铁矿粗尾砂胶结充填的L管自流输送阻力模拟试验研究,证明了在充填料浆中添加适量的悬浮剂(简称MSP),可使其具有良好的悬浮性、流动性,减少了料浆对管道的磨损,可有效解决充填料浆在自流输送中的分层、离析、沉砂等现象,在矿山行业有较好推广前景。

  2. PT-symmetric quantum theory

    Science.gov (United States)

    Bender, Carl M.

    2015-07-01

    The average quantum physicist on the street would say that a quantum-mechanical Hamiltonian must be Dirac Hermitian (invariant under combined matrix transposition and complex conjugation) in order to guarantee that the energy eigenvalues are real and that time evolution is unitary. However, the Hamiltonian H = p2 + ix3, which is obviously not Dirac Hermitian, has a positive real discrete spectrum and generates unitary time evolution, and thus it defines a fully consistent and physical quantum theory. Evidently, the axiom of Dirac Hermiticity is too restrictive. While H = p2 + ix3 is not Dirac Hermitian, it is PT symmetric; that is, invariant under combined parity P (space reflection) and time reversal T. The quantum mechanics defined by a PT-symmetric Hamiltonian is a complex generalization of ordinary quantum mechanics. When quantum mechanics is extended into the complex domain, new kinds of theories having strange and remarkable properties emerge. In the past few years, some of these properties have been verified in laboratory experiments. A particularly interesting PT-symmetric Hamiltonian is H = p2 - x4, which contains an upside-down potential. This potential is discussed in detail, and it is explained in intuitive as well as in rigorous terms why the energy levels of this potential are real, positive, and discrete. Applications of PT-symmetry in quantum field theory are also discussed.

  3. Comparison of conventional standard tube agglutination test and rose bengal precipitation test in determining brucellosis%常规试管凝集试验与虎红平板试验判断布氏杆菌病的比较

    Institute of Scientific and Technical Information of China (English)

    李玲; 王勤; 曹培义

    2013-01-01

    Objective:To explore a fast,accurate,sensitive test to diagnose brucellosis.Methods:The rose bengal precipitation test (RBPT) and standard tube agglutination test (SAT) were employed.Results:The positive rate of standard tube agglutination test was 35.7%,while that of rose bengal precipitation test was 38.1%,the positive coincidence rate was 93.8%.The rose bengal precipitation test had stronger sensitivity,while the standard tube agglutination test had a higher specificity.Conclusion:Rose bengal precipitation test is suitable for screening and epidemiological research in wide range of brucellosis.%目的:寻找一种快速、准确、敏感性强的试验方法诊断布氏杆菌病.方法:虎红平板凝集试验和试管凝集试验.结果:试管凝集试验阳性检出率为35.7%,虎红平板凝集试验阳性检出率为38.1%,阳性符合率为93.8%.虎红平板凝集试验的灵敏性较强.试管凝集试验有良好的特异性.结论:虎红平板凝集试验适用于对布氏杆菌病大范围的筛查及流行病学调查.

  4. Demonstration for the Applicability of the EPRI ETSS on the SG Tube Wear Defects Formed at the Tube Support Structure

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ki Seok; Cheon, Keun Young; Nam, Min Woo [Korea Hydro and Nuclear Power Co. Ltd, Daejeon (Korea, Republic of); Min, Kyong Mahn [Universal Monitoring and Inspection Inc., Daejeon (Korea, Republic of)

    2013-10-15

    In this paper, the authorized EPRI ETSS 27906.2 applied to the detection of tapered wear volumetric indications and depth sizing within the free span area, loose part not present was reviewed and applied to the site SG tubes for getting the actual value of the wear depth and providing structural integrity interpretation based on engineering evaluation. The experiment to demonstrate the applicability of EPRI ETSS was performed by the employment of the newly prepared STD tube and resulted in ensuring the effectiveness and equivalency of the EPRI ETSS as well. The authorized EPRI ETSS 27906.2 for getting the actual value of the wear depth and providing structural integrity interpretation based on engineering evaluation was reviewed and applied to the site SG tubes. The testing results were reviewed with the influences of SG tube material and the support structure. The impact of the tube materials was insignificant and that of the tube support structure showed somewhat conservative results. The testing resulted in successful demonstration of applicability of the EPRI ETSS on the SG tube wear defects at the tube support. One of the major flaw mechanisms detected in the currently operating domestic OPR-1000 pressurized water reactors(PWR's) steam generator(SG) tubes is wear defect. In general, wear defect has been constantly detected in the upper tube bundle imposed to the flow induced vibration interaction between tube and its support structure, and the quantity of the affected tubes has also shown the tendency to increase as plant operation life is added. In order to take appropriate measures and maintain the structural integrity for the SG tubes, wear defect is currently categorized as active damage mechanism and the tubes containing 40% or greater wear depth of the nominal tube wall thickness shall be plugged per SGMP(SG Management Program) Recently, a fairly large amplitude of wear defects on the Batwing(BW), one of the upper tube support structures in the SG

  5. Experimental investigation of air relative humidity (RH) cycling tests on MEA/cell aging in PEMFC. Pt. I. Study of high RH cycling test with air RH at 62%/100%

    Energy Technology Data Exchange (ETDEWEB)

    Huang, B.T.; Chatillon, Y.; Bonnet, C.; Lapicque, F. [Laboratoire Reactions et Genie des Procedes, CNRS-Nancy University, Nancy (France); Leclerc, S. [Laboratoire d' Energetique et de Mecanique Theorique et Appliquee, CNRS-Nancy University, Vandoeuvre-les-Nancy (France); Hinaje, M.; Rael, S. [Groupe de Recherche en Electrotechnique et Electronique de Nancy, CNRS-Nancy University, Vandoeuvre-les-Nancy (France)

    2012-06-15

    The effect of high air relative humidity (RH) cycling (RH{sub C} 62%/100%) on the degradation mechanisms of a single (5 x 5 cm{sup 2}) proton exchange membrane fuel cells was investigated. The cell performance was compared to a cell operated at constant humidification (RH{sub C} = 62%). Runs were conducted over approximately 1,500 h at 0.3 A cm{sup -2}. The overall loss in cell performance for the high RH cycling test was 12 {mu}V h{sup -1} whereas it was at 3 {mu}V h{sup -1} under constant humidification. Impedance spectroscopy reveals that the ohmic and charge transfer resistances were little modified in both runs. H{sub 2} crossover measurement indicated that both high RH cycling and constant RH test did not promote serious effect on gas permeability. The electroactive surface loss for anode and cathode during high air RH cycling was more significant than at constant RH operation. The water uptake determined by {sup 1}H nuclear magnetic resonance within the membrane electrode assembly (MEA) after high RH cycling was reduced by 12% in comparison with a fresh MEA. Transmission electron microscopy showed bubbles and pinholes formation in the membrane, catalyst particles agglomeration (also observed by X-ray diffraction), catalyst particles migration in the membrane and thickness reduction of the catalytic layers. Scanning electron microscopy was conducted to observe the changes in morphology of gas diffusion layers after the runs. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  6. Tube-Forming Assays.

    Science.gov (United States)

    Brown, Ryan M; Meah, Christopher J; Heath, Victoria L; Styles, Iain B; Bicknell, Roy

    2016-01-01

    Angiogenesis involves the generation of new blood vessels from the existing vasculature and is dependent on many growth factors and signaling events. In vivo angiogenesis is dynamic and complex, meaning assays are commonly utilized to explore specific targets for research into this area. Tube-forming assays offer an excellent overview of the molecular processes in angiogenesis. The Matrigel tube forming assay is a simple-to-implement but powerful tool for identifying biomolecules involved in angiogenesis. A detailed experimental protocol on the implementation of the assay is described in conjunction with an in-depth review of methods that can be applied to the analysis of the tube formation. In addition, an ImageJ plug-in is presented which allows automatic quantification of tube images reducing analysis times while removing user bias and subjectivity.

  7. Chest tube insertion - slideshow

    Science.gov (United States)

    ... presentations/100008.htm Chest tube insertion - series—Normal anatomy To use the sharing features ... pleural space is the space between the inner and outer lining of the lung. It is normally very thin, and lined only ...

  8. Snorkeling and Jones tubes

    OpenAIRE

    Lam, Lewis Y. W.; Weatherhead, Robert G.

    2015-01-01

    We report a case of tympanic membrane rupture during snorkeling in a 17-year-old young man who had previously undergone bilateral Jones tubes placed for epiphora. To our knowledge, this phenomenon has not been previously reported.

  9. Snorkeling and Jones tubes.

    Science.gov (United States)

    Lam, Lewis Y W; Weatherhead, Robert G

    2015-01-01

    We report a case of tympanic membrane rupture during snorkeling in a 17-year-old young man who had previously undergone bilateral Jones tubes placed for epiphora. To our knowledge, this phenomenon has not been previously reported.

  10. Nasogastric feeding tube

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/patientinstructions/000182.htm Nasogastric feeding tube To use the sharing features on this ... the nose. It can be used for all feedings or for giving a person extra calories. It ...

  11. Ear tube insertion - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100045.htm Ear tube insertion - series—Normal anatomy To use the ... 4 Overview The eardrum (tympanic membrane) separates the ear canal from the middle ear. Review Date 8/ ...

  12. Kinking of medical tubes.

    Science.gov (United States)

    Ingles, David

    2004-05-01

    The phenomenon of kinking in medical tubing remains a problem for some applications, particularly critical ones such as transporting gasses or fluids. Design features are described to prevent its occurrence.

  13. A simple device to teach tube thoracostomy.

    Science.gov (United States)

    Ching, Jessica A; Wachtel, Thomas L

    2011-06-01

    Chest tube insertion is an important component of medical and surgical education. This article reports a cost-effective and easily reproducible method for hands-on education of tube thoracostomy placement. A wood base is constructed, and a large rack of ribs are secured to simulate the thorax. Partially inflated examination gloves and bagels are used to simulate the lung and diaphragm, respectively. A life-like, cost-efficient thoracostomy model is created allowing for proficiency training in chest tube insertion. According to Advanced Trauma Life Support criteria, 123 military personnel were satisfactory, 4 remedial, and 7 instructor potential using the described model. We have developed a simple, inexpensive training device for insertion of chest tubes and tested it on 134 military personnel.

  14. X-ray tubes study and design

    CERN Document Server

    Sardari, D

    1990-01-01

    This thesis contain both theoretical and experimental works. Theoretical aspect includes X-Ray tubes case study and design principles, in the introduced design process, anode-cathode distance, vacuum needed, filament size, anode face angle and shape and size of focusing electrodes can be found. A method for specification of tungsten lager thickness on anode is also introduced. Using computer simulation, electron trajectory between cathode-anode is obtained, This work is presented in the first International Conference on Control and Modeling, Tehran, 1990. Experimental work contains manufacturing more than 10 tubes and test each of them. One of these tubes can with stand up to 50 KV. Filament can be heated by passing a 2.1 A current. In these conditions anode current is 1.2 m A. Using this tube, some radiographs have been taken.

  15. Power vacuum tubes handbook

    CERN Document Server

    Whitaker, Jerry

    2012-01-01

    Providing examples of applications, Power Vacuum Tubes Handbook, Third Edition examines the underlying technology of each type of power vacuum tube device in common use today. The author presents basic principles, reports on new development efforts, and discusses implementation and maintenance considerations. Supporting mathematical equations and extensive technical illustrations and schematic diagrams help readers understand the material. Translate Principles into Specific Applications This one-stop reference is a hands-on guide for engineering personnel involved in the design, specification,

  16. NMR Field regulation with the PT2026 Teslameter and the RCS Magnet in Building 287

    CERN Document Server

    Patz, Evan; King, Quentin; CERN. Geneva. TE Department

    2016-01-01

    In the summer of 2016, the TE-EPC group collaborated with Metrolab Technology SA on a project to regulate magnetic field using a new PT2026 NMR teslameter. Tests using a PT2026 NMR teslameter and the results are presented in this paper.

  17. Aeronautical tubes and pipes

    Science.gov (United States)

    Beauclair, N.

    1984-12-01

    The main and subcomponent French suppliers of aircraft tubes and pipes are discussed, and the state of the industry is analyzed. Quality control is essential for tubes with regard to their i.d. and metallurgical compositions. French regulations do not allow welded seam tubes in hydraulic circuits unless no other form is available, and then rustproofed steel must be installed. The actual low level of orders for any run of tubes dictates that the product is only one of several among the manufacturers' line. Automation, both in NDT and quality control, assures that the tubes meet specifications. A total of 10 French companies participate in the industry, serving both civil and military needs, with some companies specializing only in titanium, steel, or aluminum materials. Concerns wishing to enter the market must upgrade their equipment to meet the higher aeronautical specifications and be prepared to furnish tubes and pipes that serve both functional and structural purposes simultaneously. Additionally, pipe-bending machines must also perform to tight specifications. Pipes can range from 0.2 mm exterior diameter to 40 mm, with wall thicknesses from 0.02 mm to 3 mm. A chart containing a list of manufacturers and their respective specifications and characteristics is presented, and a downtrend in production with reduction of personnel is noted.

  18. A gas laser tube

    Energy Technology Data Exchange (ETDEWEB)

    Tetsuo, F.; Tokhikhide, N.

    1984-04-19

    A gas laser tube is described in which contamination of the laser gas mixture by the coolant is avoided, resulting in a longer service life of the mirrors. The holder contains two tubes, one inside the other. The laser gas mixture flows through the internal tube. An electrode is fastened to the holder. The coolant is pumped through the slot between the two tubes, for which a hole is cut into the holder. The external tube has a ring which serves to seal the cavity containing the coolant from the atmosphere. The internal tube has two rings, one to seal the laser gas mixture and the other to seal the coolant. A slot is located between these two rings, which leads to the atmosphere (the atmosphere layer). With this configuration, the degradation of the sealing properties of the internal ring caused by interaction with the atmospheric layer is not reflected in the purity of the laser gas mixture. Moreover, pollution of the mirrors caused by the penetration of the coolant into the cavity is eliminated.

  19. Dynamic tube/support interaction in heat exchanger tubes

    Energy Technology Data Exchange (ETDEWEB)

    Chen, S.S.

    1991-01-01

    The supports for heat exchanger tubes are usually plates with drilled holes; other types of supports also have been used. To facilitate manufacture and to allow for thermal expansion of the tubes, small clearances are used between tubes and tube supports. The dynamics of tube/support interaction in heat exchangers is fairly complicated. Understanding tube dynamics and its effects is important for heat exchangers. This paper summarizes the current state of the art on this subject and to identify future research needs. Specifically, the following topics are discussed: dynamics of loosely supported tubes, tube/support gap dynamics, tube response in flow, tube damage and wear, design considerations, and future research needs. 55 refs., 1 fig.

  20. Oxygen reduction activity of Pt and Pt-alloys in acid electrolyte

    Energy Technology Data Exchange (ETDEWEB)

    Paulus, Ursula A. [Paul Scherrer Inst., CH-5232 Villigen PSI (Switzerland); Schmidt, Thomas J.; Stamenkovic, Vojislav R.; Markovic, Nenad M.; Ross, Philip N. [Material Science Division, Lawrence Berkeley National Laboratory, University of California, Berkeley, CA 94720 (United States)

    2001-07-01

    The oxygen reduction reaction (ORR) has been studied on polycrystalline (pc) Pt, Pt{sub 3}Ni and Pt{sub 3}Co bulk alloy electrodes and on carbon supported Pt, PtNi and PtCo alloy catalysts. Base voltammetry measurements as well as complementary Auger Electron Spectroscopy (AES) and Low Energy Ion Scattering (LEIS) on bulk electrodes and High Resolution Transmission Electron Microscopy (HRTEM)-analysis on the supported catalysts allow an estimation of the surface composition. By using the rotating ring-disk electrode (RRDE) technique both the kinetic analysis of the ORR and in parallel the detection and quantification of the amount of peroxide produced during the ORR are possible. The activity for the ORR increases in the order Pt < Pt{sub 3}Ni < Pt{sub 3}Co for equally prepared bulk alloys and Pt < Pt{sub 3}Ni {approx} Pt{sub 3}CO < PtCo for the carbon supported catalysts, respectively. It was proposed that the mechanism for the ORR is the same on pure Pt and the PtNi and PtCo alloys. (author)

  1. Standardized performance tests of collectors of solar thermal energy-a flat-plate collector with a single-tube serpentine flow distribution

    Science.gov (United States)

    Johnson, S.

    1976-01-01

    This preliminary data report gives basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficienty is correlated in terms of inlet temperature and flux level.

  2. Hydrogen Adsorption on Pt, Rh and Pt-Rh Electrodes

    Institute of Scientific and Technical Information of China (English)

    贾梦秋; A.M.Meretskyi

    2005-01-01

    The hydrogen adsorption on Pt-Rh alloys in sulfuric acid aqueous solutions was studied by the method of cathode pulses. Hydrogen adsorption on the electrode with all ratio of alloy components (ωRh = 0-100%) is well described by the Temkin logarithmic isotherm. The surface coverage by adsorbed hydrogen at the same potential is decreased with increasing content of rhodium in the system. A linear dependence of adsorption peak potential on the alloy compositions in the case of weakly bonded adsorbed hydrogen is established. Hydrogen adsorption heat as a function of surface coverage for Pt-Rh-electrodes was obtained. The shape of the current-potential curve and position of the weakly bonded hydrogen adsorption on the potential scale are all related to alloy compositions, thus can serve as the basis for the determination surface composition of allovs.

  3. 高压高产气井试气求产过程中油管挤毁失效分析%Failure Analysis on the Collapsed Tubing of the High Pressure and High Production Gas Well in the Process of Testing and Production

    Institute of Scientific and Technical Information of China (English)

    薛继军; 赵滨; 赵赫

    2014-01-01

    One of the tubing used in the gas well under the high pressure and high production has occurred in the split,fall,collapse and severe diapirism of tube body in the trial extraction process.This paper have a test of tube so that certain the reason that split,fall,collapsed and se-vere diapirism of tube body by the analysis of the macroscopic,physical and chemical properties, microscopic metallographic.The result shows that gas,liquid pipe ram and solid multiphase flow in tube may be formatted the instantaneous negative pressure and increase the likelihood of the tubing were collapsed in the process of the gas testing and production.Then it has resulted in clogging,severe erosion,thinning wall and piercing in tube.Finally the tube has occurred in frac-ture because of the tensile strength.%某高压高产气井试气用油管在试提中发生管体断裂掉落,并有管体挤毁和严重刺穿现象。通过对油管进行宏观分析、理化性能分析、微观金相分析试验,以确定油管发生断裂掉落以及挤毁和刺穿的原因。结果表明:在放喷求产过程中油管内存在气、液、固等多相流,可能会形成瞬时负压,增加了油管被挤毁变形的可能性;随后造成流道堵塞,油管内冲蚀严重,壁厚变薄发生刺穿,最后因拉伸强度不足而发生断裂。

  4. Surface termination of CePt5/Pt (111 ): The key to chemical inertness

    Science.gov (United States)

    Praetorius, C.; Zinner, M.; Held, G.; Fauth, K.

    2015-11-01

    The surface termination of CePt5/Pt (111 ) is determined experimentally by LEED-IV. In accordance with recent theoretical predictions, a dense Pt terminated surface is being found. Whereas the CePt5 volume lattice comprises Pt kagome layers, additional Pt atoms occupy the associated hole positions at the surface. This finding provides a natural explanation for the remarkable inertness of the CePt5 intermetallic. Implications of the structural relaxations determined by LEED-IV analysis are discussed with regard to observations by scanning tunneling microscopy and electron spectroscopies.

  5. Studies of surface processes of electrocatalytic reduction of CO2 on Pt(210), Pt(310) and Pt(510)

    Institute of Scientific and Technical Information of China (English)

    FAN; ChunJie; FAN; YouJun; ZHEN; ChunHua; ZHENG; QingWei; SUN; ShiGang

    2007-01-01

    Surface processes of CO2 reduction on Pt(210), Pt(310), and Pt(510) electrodes were studied by cyclic voltammetry. Different surface structures of these platinum single crystal electrodes were obtained by various treatment conditions. The experimental results illustrated that the electrocatalytic activity of Pt single crystal electrodes towards CO2 reduction is decreased in an order of Pt(210)>Pt(310)>Pt(510), i.e., with the decrease of (110) step density on well-defined surfaces. When the surfaces were reconstructed due to oxygen adsorption, the catalytic activity of all the three electrodes has been enhanced to a certain extent. Although the activity order remains unchanged, the electrocatalytic activity has been enhanced more significantly as the density of (110) step sites is more intensive on the Pt single crystal surface. It has revealed that the more open the surface structure is, the more active the Pt single crystal electrode will be, and the easier for the electrode to be transformed into a surface structure that exhibits higher activity under external inductions. However, the relatively ordered surfaces of Pt single crystal electrode are comparatively stable under the same external inductions. The present study has gained knowledge on the interaction between CO2 and Pt single crystal electrode surfaces at a microscopic level, and thrown new insight into understanding the surface processes of electrocatalytic reduction of CO2.

  6. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home > NEI YouTube Videos > NEI YouTube Videos: Amblyopia NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract ...

  7. Effect of component distribution and nanoporosity in CuPt nanotubes on electrocatalysis of the oxygen reduction reaction.

    Science.gov (United States)

    Guo, Huizhang; Liu, Xiang; Bai, Chengdong; Chen, Yuanzhi; Wang, Laisen; Zheng, Mingsen; Dong, Quanfeng; Peng, Dong-Liang

    2015-02-01

    Pt-based bimetallic electrocatalysts hold great potential in the oxygen reduction reaction (ORR) in current fuel-cell prototypes. However, they also face challenges from drastic dealloying of less-noble metals and coalescence of small nanoparticles. Porous and structure-ordered nanotubes may hold the potential to improve the stability of bimetallic electrocatalysts. Herein, we report a method to prepare CuPt nanotubes and porous Cu3 Pt intermetallic nanorods through a controlled galvanic replacement reaction and heat treatment process. The effect of the geometric features and compositional segregation on the electrocatalysis of the ORR was clarified. The outstanding performance of the Cu3 Pt/C-700 catalyst in the ORR relative to that of CuPt/C-RT was mainly attributed to the nanoporosity of the catalyst, whereas the enhanced specific activity on CuPt/C-RT after potential cycling was attributed to the interaction between the CuPt alloyed core and the Pt shell in the tube wall.

  8. Highly active Pt3Pb and core-shell Pt3Pb-Pt electrocatalysts for formic acid oxidation.

    Science.gov (United States)

    Kang, Yijin; Qi, Liang; Li, Meng; Diaz, Rosa E; Su, Dong; Adzic, Radoslav R; Stach, Eric; Li, Ju; Murray, Christopher B

    2012-03-27

    Formic acid is a promising chemical fuel for fuel cell applications. However, due to the dominance of the indirect reaction pathway and strong poisoning effects, the development of direct formic acid fuel cells has been impeded by the low activity of existing electrocatalysts at desirable operating voltage. We report the first synthesis of Pt(3)Pb nanocrystals through solution phase synthesis and show they are highly efficient formic acid oxidation electrocatalysts. The activity can be further improved by manipulating the Pt(3)Pb-Pt core-shell structure. Combined experimental and theoretical studies suggest that the high activity from Pt(3)Pb and the Pt-Pb core-shell nanocrystals results from the elimination of CO poisoning and decreased barriers for the dehydrogenation steps. Therefore, the Pt(3)Pb and Pt-Pb core-shell nanocrystals can improve the performance of direct formic acid fuel cells at desired operating voltage to enable their practical application. © 2012 American Chemical Society

  9. Nanomechanical and Macrotribological Properties of CVD-Grown Graphene as a Middle Layer between Metal Pt Cylinders and SiO2/Si Substrate

    Directory of Open Access Journals (Sweden)

    Hongyan Wu

    2015-01-01

    Full Text Available The CVD-grown graphene as a middle layer was introduced between Pt cylinders and SiO2/Si to extend the application of graphene for improving the wear performance of microelectromechanical systems. Periodic arrays of Pt cylinders were prepared on the graphene/SiO2/Si (Pt/graphene and SiO2/Si substrate (Pt/SiO2 using the magnetron sputtering technique. To characterize Pt/graphene and Pt/SiO2, nanoindentation and macrotribological tests were performed. The results showed that the friction coefficient was lower and the wear lifetime of Pt/graphene was longer than those of Pt/SiO2. Graphene, as a middle layer, was not only observed to have significant influence on the mechanical properties (i.e., microhardness and elastic modulus, but also found to improve the adhesive strength between SiO2/Si and Pt cylinders.

  10. An apparatus with a horizontal capillary tube intended for measurement of the surface tension of supercooled liquids

    Directory of Open Access Journals (Sweden)

    Vinš Václav

    2015-01-01

    Full Text Available New experimental apparatus for measurement of the surface tension of liquids under the metastable supercooled state has been designed and assembled in the study. The measuring technique is similar to the method employed by P.T. Hacker [NACA TN 2510] in 1951. A short liquid thread of the liquid sample was sucked inside a horizontal capillary tube partly placed in a temperature-controlled glass chamber. One end of the capillary tube was connected to a setup with inert gas which allowed for precise tuning of the gas overpressure in order of hundreds of Pa. The open end of the capillary tube was precisely grinded and polished before the measurement in order to assure planarity and perpendicularity of the outer surface. The liquid meniscus at the open end was illuminated by a laser beam and observed by a digital camera. Application of an increasing overpressure of the inert gas at the inner meniscus of the liquid thread caused variation of the outer meniscus such that it gradually changed from concave to flat and subsequently convex shape. The surface tension at the temperature of the inner meniscus could be evaluated from the overpressure corresponding to exactly planar outer meniscus. Detailed description of the new setup together with results of the preliminary tests is provided in the study.

  11. Development of an Astronomical Infrared PtSi Camera

    Science.gov (United States)

    Hong, S. S.; Ueno, M.; Koo, B. C.; Kim, K.-T.; Kim, C. Y.; Oh, K. S.; Lee, M. G.; Lee, H. M.; Kang, Y. W.; Park, W.-K.

    1996-12-01

    We have built a near-infrared imaging camera with a PtSi array detector manufactured the Mitsubishi Company. The PtSi detector is sensitive in the wavelength range 1 to 5micrometer. Quantum efficiency of PtSi is much lower than that of InSb and HgCdTe types. However, the PtSi array has advantages over the latter ones:(i)The read-out noise is very low;(ii)the characteristics of the array elements are uniform and stable; (iii)it is not difficult to make a large PtSi array; and (iv)consequently the price is affordably low. The array used consists of 512 x 512 pixels and its size is 10.2 mm x 13.3 mm. The filter wheel of the camera is equipped with J, H, K filters, and an aluminum plate for measuring the dark noise. The dewar is cooled with liquid nitrogen. We have adopted a method of installing the clock pattern and the observing softwares in the RAM, which can be easily used for other systems. We have developed a software with a pull-down menu for operating the camera and data acquisition. The camera has been tested by observing Orionis.

  12. Nanomechanical and Macrotribological Properties of CVD-Grown Graphene as a Middle Layer between Metal Pt Cylinders and SiO2/Si Substrate

    OpenAIRE

    Hongyan Wu; Zhengbin Gu; Shantao Zhang; G. Hussain

    2015-01-01

    The CVD-grown graphene as a middle layer was introduced between Pt cylinders and SiO2/Si to extend the application of graphene for improving the wear performance of microelectromechanical systems. Periodic arrays of Pt cylinders were prepared on the graphene/SiO2/Si (Pt/graphene) and SiO2/Si substrate (Pt/SiO2) using the magnetron sputtering technique. To characterize Pt/graphene and Pt/SiO2, nanoindentation and macrotribological tests were performed. The results showed that the friction coef...

  13. Efficient synthesis of titania nanotubes and enhanced photoresponse of Pt decorated TiO2 for water splitting

    Institute of Scientific and Technical Information of China (English)

    Yuxin YIN; Xin TAN; Feng HOU; Lin ZHAO

    2009-01-01

    We investigated the effect of HMT (hexa-methylenetetraamine) on the anodic growth of TiO2 nanotube arrays. The tube length increases to 4.3μm Adsorption of HMT on the TiO2 surface is shown to markedly decrease the chemical dissolution rate of tube mouth, resulting in longer nanotube length. Furthermore, Pt nanoparticles were successfully deposited on the surface of TiO2 nanotubes by ac electrodeposition method. The TiO2/Pt composites were characterized by field emission scanning electron microscope (FESEM), X-ray photoelec-tron spectra (XPS), and photoelectrochemistry. An enhancement in photocurrent density has been achieved upon modification of TiO2 nanotubes with Pt nanoparti-cles.

  14. PT Symmetry as a Generalization of Hermiticity

    CERN Document Server

    Wang, Qing-hai; Zhang, Jie-hong

    2010-01-01

    The Hilbert space in PT-symmetric quantum mechanics is formulated as a linear vector space with a dynamic weight function in the inner product. The most general PT-symmetric matrix Hamiltonians are constructed for 2*2 and 3*3 cases. In the former case, the PT-symmetric Hamiltonian represents the most general matrix Hamiltonian with a real spectrum. In both cases, the Hermitian matrix is shown to be a special case of PT-symmetric matrices. This finding confirms and strengthens the early belief that the PT-symmetric quantum mechanics is a generalization of the conventional Hermitian quantum mechanics.

  15. Influence of tube spinning on formability of friction stir welded aluminum alloy tubes for hydroforming application

    Energy Technology Data Exchange (ETDEWEB)

    Wang, X.S. [State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, Harbin 150001 (China); Hu, Z.L., E-mail: zhilihuhit@163.com [State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, Harbin 150001 (China); Hubei Key Laboratory of Advanced Technology of Automobile Parts, Wuhan University of Technology, Wuhan 430070 (China); State Key Laboratory of Materials Processing and Die and Mould Technology, Huazhong University of Science and Technology (China); Yuan, S.J. [State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, Harbin 150001 (China); Hua, L. [Hubei Key Laboratory of Advanced Technology of Automobile Parts, Wuhan University of Technology, Wuhan 430070 (China)

    2014-06-01

    Due to economic and ecological reasons, the application of tailor-welded blanks of aluminum alloy has gained more and more attention in manufacturing lightweight structures for automotives and aircrafts. In the study, the research was aimed to highlight the influence of spinning on the formability of FSW tubes. The microstructural characteristics of the FSW tubes during spinning were studied by electron backscattered diffraction (EBSD) and transmission electron microscopy (TEM). The formability of the FSW tubes with different spinning reduction was assessed by hydraulic bulge test. It is found that the spinning process shows a grain refinement of the tube. The grains of the FSW tube decrease with increasing thickness reduction, and the effect of grain refinement is more obvious for the BM compared to that of the weld. The difference of grain size and precipitates between the weld and BM leads to an asymmetric W-type microhardness distribution after spinning. The higher thickness reduction of the tube, the more uniform distribution of grains and precipitates it shows, and consequently results in more significant increase of strength. As compared with the result of tensile test, the tube after spinning shows better formability when the stress state changes from uniaxial to biaxial stress state.

  16. Gram-Scale-Synthesized Pd2Co-Supported Pt Monolayer Electrocatalysts for Oxygen Reduction Reaction

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, W.; Sasaki, K; Su, D; Zhu, Y; Wang, J; Adzic, R

    2010-01-01

    Gram-scale synthesis of Pt{sub ML} electrocatalysts with a well-defined core-shell structure has been carried out using method involving galvanic displacement of an underpotential deposition Cu layer. The Pt shell thickness can be controlled by stepwise deposition. The Pt{at}Pd{sub 2}Co/C nanoparticles were characterized by X-ray powder diffraction, aberration-corrected scanning transmission electron microscopy, high-resolution energy-loss spectrometry, and in situ X-ray absorption spectroscopy. A complete Pt shell of 0.6 nm on a Pd{sub 2}Co core has been confirmed. The Pt{at}Pd{sub 2}Co/C core-shell electrocatalysts showed a very high activity for the oxygen reduction reaction; the Pt mass and specific activity were 0.72 A mg{sub Pt}{sup -1} and 0.5 mA cm{sup -2}, respectively (3.5 and 2.5 times higher than the corresponding values for commercial Pt catalysts), at 0.9 V in 0.1 M HClO{sub 4} at room temperature. In an accelerated potential cycling test, a loss in active surface area and a decrease in catalytic activity for gram-scale-synthesized Pt{sub ML} catalysts were also determined.

  17. Tracking chamber made of 15-mm mylar drift tubes

    Science.gov (United States)

    Kozhin, A.; Borisov, A.; Bozhko, N.; Fakhrutdinov, R.; Plotnikov, I.

    2017-05-01

    We are presenting a drift chamber composed from three layers of mylar drift tubes with outer diameter 15 mm. The pipe is made of strip of mylar film 125 micrometers thick covered with aluminium from the both sides. A strip of mylar is wrapped around the mandrel. Pipe is created by ultrasonic welding. A single drift tube is self-supported structure withstanding 350 g wire tension without supports and internal overpressure. About 400 such tubes were assembled. Design, quality control procedures of the drift tubes are described. Seven chambers were glued from these tubes of 560 mm length. Each chamber consists of 3 layers, 16 tubes per layer. Several chambers were tested with cosmic rays. Results of the tests, counting rate plateau and coordinate resolution are presented.

  18. Contribution of a heparin-binding haemagglutinin interferon-gamma release assay to the detection of Mycobacterium tuberculosis infection in HIV-infected patients: comparison with the tuberculin skin test and the QuantiFERON-TB Gold In-tube.

    Science.gov (United States)

    Wyndham-Thomas, Chloé; Dirix, Violette; Schepers, Kinda; Martin, Charlotte; Hildebrand, Marc; Goffard, Jean-Christophe; Domont, Fanny; Libin, Myriam; Loyens, Marc; Locht, Camille; Van Vooren, Jean-Paul; Mascart, Françoise

    2015-02-14

    The screening and treatment of latent tuberculosis (TB) infection reduces the risk of progression to active disease and is currently recommended for HIV-infected patients. The aim of this study is to evaluate, in a low TB incidence setting, the potential contribution of an interferon-gamma release assay in response to the mycobacterial latency antigen Heparin-Binding Haemagglutinin (HBHA-IGRA), to the detection of Mycobacterium tuberculosis infection in HIV-infected patients. Treatment-naïve HIV-infected adults were recruited from 4 Brussels-based hospitals. Subjects underwent screening for latent TB using the HBHA-IGRA in parallel to a classical method consisting of medical history, chest X-ray, tuberculin skin test (TST) and QuantiFERON-TB Gold In-Tube (QFT-GIT). Prospective clinical and biological follow-up ensued, with repeated testing with HBHA-IGRA. A group of HIV-infected patients with clinical suspicion of active TB was also recruited and tested with the HBHA-IGRA. Multiplex analysis was performed on the culture supernatants of this in-house assay to identify test read-outs alternative to interferon-gamma that could increase the sensitivity of the test. Among 48 candidates enrolled for screening, 9 were identified with latent TB by TST and/or QFT-GIT results. Four of these 9 patients and an additional 3 screened positive with the HBHA-IGRA. This in-house assay identified all the patients that were positive for the TST and showed the best concordance with the presence of a M. tuberculosis exposure risk. During follow-up (median 14 months) no case of active TB was reported and HBHA-IGRA results remained globally constant. Fourteen HIV-infected patients with clinical suspicion of active TB were recruited. Active TB was confirmed for 6 of them among which 3 were HBHA-IGRA positive, each with very high interferon-gamma concentrations. All patients for whom active TB was finally excluded, including 2 non-tubercular mycobacterial infections, had negative HBHA

  19. Effect of tube size on electromagnetic tube bulging

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The commercial finite code ANSYS was employed for the simulation of the electromagnetic tube bulging process. The finite element model and boundary conditions were thoroughly discussed. ANSYS/EMAG was used to model the time varying electromagnetic field in order to obtain the radial and axial magnetic pressure acting on the tube. The magnetic pressure was then used as boundary conditions to model the high velocity deformation of various length tube with ANSYS/LSDYNA. The time space distribution of magnetic pressure on various length tubes was presented. Effect of tube size on the distribution of radial magnetic pressure and axial magnetic pressure and high velocity deformation were discussed. According to the radial magnetic pressure ratio of tube end to tube center and corresponding dimensionless length ratio of tube to coil, the free electromagnetic tube bulging was studied in classification. The calculated results show good agreements with practice.

  20. A prospective randomized trial of transnasal ileus tube vs nasogastric tube for adhesive small bowel obstruction

    Institute of Scientific and Technical Information of China (English)

    Xiao-Li Chen; Fena Ji; Qi Lin; Yi-Peng Chen; Jian-Jiang Lin; Feng Ye; Ji-Ren Yu; Yi-Jun Wu

    2012-01-01

    AIM:To study the therapeutic efficacy of a new transnasal ileus tube advanced endoscopically for adhesive small bowel obstruction.METHODS:A total of 186 patients with adhesive small bowel obstruction treated from September 2007 to February 2011 were enrolled into this prospective randomized controlled study.The endoscopically advanced new ileus tube was used for gastrointestinal decompression in 96 patients and ordinary nasogastric tube (NGT) was used in 90 patients.The therapeutic efficacy was compared between the two groups.RESULTS:Compared with the NGT group,the ileus tube group experienced significantly shorter time for relief of clinical symptoms and improvement in the findings of abdominal radiograph (4.1 ± 2.3 d vs 8.5 ± 5.0 d) and laboratory tests (P < 0.01).The overall effectiveness rate was up to 89.6% in the ileus tube group and 46.7% in the NGT group (P < 0.01).And 10.4% of the patients in the ileus tube group and 53.3% of the NGT group underwent surgery.For recurrent adhesive bowel obstruction,ileus tube was also significantly more effective than NGT (95.8% vs 31.6%).In the ileus tube group,the drainage output on the first day and the length of hospital stay were significantly different depending on the treatment success or failure (P < 0.05).The abdominal radiographic improvement was correlated with whether or not the patient underwent surgery.CONCLUSION:Ileus tube can be used for adhesive small bowel obstruction.Endoscopic placement of the ileus tube is convenient and worthy to be promoted despite the potential risks.

  1. Automatic ultrasonic inspection system for wear determination in calandria tubes of Embalse Nuclear Power Plant

    Science.gov (United States)

    Katchadjian, Pablo; Desimone, Carlos; Garcia, Alejandro; Antonaccio, Carlos; Schroeter, Fernando; Molina, Héctor

    2015-03-01

    Embalse Nuclear Power Plant (CNE) (CANDU design) is reaching its end of life and due to elapsed operating time the problem of deformation by accelerated creep occurs in the pressure tubes (PT), leading to a possible contact between calandria tubes (CT), concentric to the PT, and some Liquid Injection Shutdown System (LISS) nozzles that pass underneath them. With determination of CT wear, after the predicted contact occurs, the wear rate of the TC could be determined and thus take less conservative measures over the remaining life of the component. This paper presents the development of an ultrasonic technique for measuring wear in CT, with nominal thickness of 1.34 mm. Because the only access is through the interior of PT, to perform this measurement it is necessary to pass through three different interfaces.

  2. Preparation of PtSnCu/C and PtSn/C electrocatalysts and activation by dealloying processes for ethanol electrooxidation; Preparacao de eletrocatalisadores PtSnCu/C e PtSn/C e ativacao por processos de dealloying para aplicacao na oxidacao eletroquuimica do etanol

    Energy Technology Data Exchange (ETDEWEB)

    Crisafulli, Rudy

    2013-06-01

    the FCC structure of Pt. The results obtained by cyclic voltammetry and chronoamperometry showed that electrocatalysts containing 30 at % or more of platinum, after chemical and electrochemical dealloying had significant improvement in electrocatalytic activity for ethanol electro-oxidation in the potential of interest. The electrocatalysts with higher efficiency for electrochemical oxidation of ethanol were PtSn/C (50:50) BR/ED > PtSnCu/C (50:40:10) AR/ED > PtSnCu/C (50:10:40) BR/CD. PtSn/C (50:50) BR/CD, PtSnCu/C (50:10:40) BR/CD, PtSnCu/C (50:40:10) AR/CD electrocatalysts and Pt/C BASF, PtSn/C (75:25) BASF commercial electrocatalysts were tested in single Direct Ethanol Fuel Cell. The results showed the following performance for ethanol electro-oxidation: PtSn/C (50:50) BR/CD > PtSnCu/C (50:40:10) AR/CD > PtSnCu/C > PtSn/C (75:25) BASF > PtSnCu/C (50:10:40) BR/CD > Pt/C BASF. (author)

  3. Condensation of refrigerants on vertical fluted tubes

    Energy Technology Data Exchange (ETDEWEB)

    Combs, S.K.; Mailen, G.S.; Murphy, R.W.

    1978-08-01

    Experiments were run to determine heat transfer performance of single vertical fluted tubes with selected fluids condensing on the outside. Working fluids included six fluorocarbons (Refrigerants 11, 21, 22, 113, 114, and 115) and a hydrocarbon (Refrigerant 600a or isobutane). The nine test tubes were of 2.54-cm (1-in.) nominal outside diameter and 1.2 m (4 ft) in length with from 0 (smooth) to 60 axial flutes. Condensing heat transfer coefficients ranged from 620 to 7900 W/m/sup 2/ . K (110 to 1400 Btu/hr . ft/sup 2/ . /sup 0/F) over the heat flux range of 2000 to 43,000 W/m/sup 2/ (920 to 13,600 Btu/hr . ft/sup 2/). All parameters are based on total condensing surface area. The data show that, for a given heat flux, a fluted tube can increase condensing coefficients up to 6.0 times smooth tube values. Further heat transfer enhancement was achieved by the use of drainage skirts on fluted tubes; these skirts effectively divided the 1.2-m (4-ft) tubes into two, four, and eight equal condensing lengths.

  4. Categorising YouTube

    Directory of Open Access Journals (Sweden)

    Thomas Mosebo Simonsen

    2011-09-01

    Full Text Available This article provides a genre analytical approach to creating a typology of the User Generated Content (UGC of YouTube. The article investigates the construction of navigationprocesses on the YouTube website. It suggests a pragmatic genre approach that is expanded through a focus on YouTube’s technological affordances. Through an analysis of the different pragmatic contexts of YouTube, it is argued that a taxonomic understanding of YouTube must be analysed in regards to the vacillation of a user-driven bottom-up folksonomy and a hierarchical browsing system that emphasises a culture of competition and which favours the already popular content of YouTube. With this taxonomic approach, the UGC videos are registered and analysed in terms of empirically based observations. The article identifies various UGC categories and their principal characteristics. Furthermore, general tendencies of the UGC within the interacting relationship of new and old genres are discussed. It is argued that the utility of a conventional categorical system is primarily of analytical and theoretical interest rather than as a practical instrument.

  5. Measurement of impulse peak insertion loss from two acoustic test fixtures and four hearing protector conditions with an acoustic shock tube

    OpenAIRE

    Murphy, William J.; Cameron J Fackler; Berger, Elliott H.; Peter B Shaw; Mike Stergar

    2015-01-01

    Impulse peak insertion loss (IPIL) was studied with two acoustic test fixtures and four hearing protector conditions at the E-A-RCAL Laboratory. IPIL is the difference between the maximum estimated pressure for the open-ear condition and the maximum pressure measured when a hearing protector is placed on an acoustic test fixture (ATF). Two models of an ATF manufactured by the French-German Research Institute of Saint-Louis (ISL) were evaluated with high-level acoustic impulses created by an a...

  6. Ovalization of Tubes Under Bending and Compression

    Science.gov (United States)

    Demer, L J; Kavanaugh, E S

    1944-01-01

    An empirical equation has been developed that gives the approximate amount of ovalization for tubes under bending loads. Tests were made on tubes in the d/t range from 6 to 14, the latter d/t ratio being in the normal landing gear range. Within the range of the series of tests conducted, the increase in ovalization due to a compression load in combination with a bending load was very small. The bending load, being the principal factor in producing the ovalization, is a rather complex function of the bending moment, d/t ratio, cantilever length, and distance between opposite bearing faces. (author)

  7. Perpendicular magnetic anisotropy of Co85Cr15/Pt multilayers

    Institute of Scientific and Technical Information of China (English)

    Pol Hwang; Baohe Li; Tao Yang; Zhonghai Zhai; Fengwu Zhu

    2004-01-01

    The CoCr/Pt bilayers and (CoCr/Pt)20 multilayers with Pt underlayer were prepared by DC magnetron sputtering. The effects of prepared condition on perpendicular magnetic anisotropy were investigated. The results show that the thickness of Pt underlayer has a great effect on the microstructure and perpendicular magnetic anisotropy of CoCr/Pt bilayers and (CoCr/Pt)20 multilayers.When the thickness of Pt underlayer increases, Pt(111) and CoCr(002) peaks of both CoCr/Pt bilayers and (CoCr/Pt)20 multilayers increase and the bilayer periodicity of the multilayers is improved. The effective magnetic anisotropy of (CoCr/Pt)20 multilayers with Pt underlayer was much larger than that of CoCr/Pt bilayers. The (CoCr/Pt)20 multilayers has a stronger perpendicular magnetic anisotropy than that of CoCr/Pt bilayers. This is ascribed to the interface magnetic anisotropy of the multilayers.

  8. Heat transfer enhancement through inner grooved copper tubes with different tube parameters

    Directory of Open Access Journals (Sweden)

    M. M. Rahman, Y. M. Ling, G. W. Soon, G. A. Kuan

    2012-01-01

    Full Text Available This paper presents the evaluation of heat transfer coefficients for the flow of R22 through internally grooved copper tubes. A series of tests were conducted using two types of tubes namely Tube A and Tube B, which have different tube parameters. The straight and horizontal test section of the test apparatus with a length of 3.67 m was heated or cooled by water circulated in a surrounding annulus. Condensation tests were conducted at mass flux rates of 180 to 537 kg/m2s and the vapor qualities ranged from a nominal value of 83% at the test section inlet to 6% at the outlet. Evaporation tests were conducted at mass flux rates of 110 to 404 kg/m2s and the nominal vapor qualities at the inlet and outlet were 0 and 85%, respectively. For both the condensation and evaporation tests, the heat transfer coefficients are found to increase as the mass flux rate increases.

  9. Tracheostomy tubes and related appliances.

    Science.gov (United States)

    Hess, Dean R

    2005-04-01

    Tracheostomy tubes are used to administer positive-pressure ventilation, to provide a patent airway, to provide protection from aspiration, and to provide access to the lower respiratory tract for airway clearance. They are available in a variety of sizes and styles, from several manufacturers. The dimensions of tracheostomy tubes are given by their inner diameter, outer diameter, length, and curvature. Differences in length between tubes of the same inner diameter, but from different manufacturers, are not commonly appreciated but may have important clinical implications. Tracheostomy tubes can be angled or curved, a feature that can be used to improve the fit of the tube in the trachea. Extra proximal length tubes facilitate placement in patients with large necks, and extra distal length tubes facilitate placement in patients with tracheal anomalies. Several tube designs have a spiral wire reinforced flexible design and have an adjustable flange design to allow bedside adjustments to meet extra-length tracheostomy tube needs. Tracheostomy tubes can be cuffed or uncuffed. Cuffs on tracheostomy tubes include high-volume low-pressure cuffs, tight-to-shaft cuffs, and foam cuffs. The fenestrated tracheostomy tube has an opening in the posterior portion of the tube, above the cuff, which allows the patient to breathe through the upper airway when the inner cannula is removed. Tracheostomy tubes with an inner cannula are called dual-cannula tracheostomy tubes. Several tracheostomy tubes are designed specifically for use with the percutaneous tracheostomy procedure. Others are designed with a port above the cuff that allows for subglottic aspiration of secretions. The tracheostomy button is used for stoma maintenance. It is important for clinicians caring for patients with a tracheostomy tube to understand the nuances of various tracheostomy tube designs and to select a tube that appropriately fits the patient.

  10. Comparison of two interferon-gamma release assays (QuantiFERON-TB Gold In-Tube and T-SPOT.TB) in testing for latent tuberculosis infection among HIV-infected adults.

    Science.gov (United States)

    Sultan, B; Benn, P; Mahungu, T; Young, M; Mercey, D; Morris-Jones, S; Miller, R F

    2013-10-01

    There is currently no 'gold standard' for diagnosis of latent tuberculosis infection (LTBI), and both the tuberculin skin test and interferon-gamma release assays (IGRAs) are used for diagnosis; the latter have a higher sensitivity than tuberculin skin tests for diagnosis of LTBI in HIV-infected individuals with lower CD4 counts. No evidence base exists for selection of IGRA methodology to identify LTBI among human immunodeficiency virus-infected patients in the UK. We prospectively evaluated two commercially available IGRA methods (QuantiFERON-TB Gold In Tube [QFG] and T-SPOT.TB) for testing LTBI among HIV-infected patients potentially nosocomially exposed to an HIV-infected patient with 'smear-positive' pulmonary tuberculosis. Among the exposed patients median CD4 count was 550 cells/µL; 105 (90%) of 117 were receiving antiretroviral therapy, of who 104 (99%) had an undetectable plasma HIV load. IGRAs were positive in 12 patients (10.3%); QFG positive in 11 (9.4%) and T-SPOT.TB positive in six (5.1%); both IGRAs were positive in five patients (4.3%). There was one indeterminate QFG and one borderline T-SPOT.TB result. Concordance between the two IGRAs was moderate (κ = 0.56, 95% confidence interval = 0.27-0.85). IGRAs were positive in only 4 (29%) of 14 patients with previous culture-proven tuberculosis. No patient developed tuberculosis during 20 months of follow-up.

  11. 超超临界锅炉小径管焊缝的超声相控阵检测工艺%Ultrasonic Phased Array Testing for Small Diameter Tube Weld of Ultra-supercritical Boiler

    Institute of Scientific and Technical Information of China (English)

    王维东; 王亦民; 孟倩倩; 曹云峰; 张振华

    2015-01-01

    A series of ultrasonic phased array inspection contrast test blocks were developed according to the distribution range of the boiler pipe weld defect,and at the same time tests were conducted on the simulation and natural defects,respectively.By making distance amplitude curve for 1 mm diameter horizontal hole,we quantified and measured indicating length of defects both inside and outside of the tube with different diameter and thickness, and thus corrected the errors of the traditional detection and established the testing method of ultrasonic phased array for small pipe weld.%根据锅炉小径管焊缝的缺陷分布范围,研制出系列超声相控阵检测的对比试块,并进行了模拟与自然缺陷的检测试验。测试采用ϕ1 mm横孔制作距离-波幅曲线,对不同外径与壁厚的内外壁缺陷进行定量与指示长度测定,修正了传统检测的误区,建立了超声相控阵小径管焊缝的检测工艺方法。

  12. Influence of age and nutritional status on the performance of the tuberculin skin test and QuantiFERON-TB gold in-tube in young children evaluated for tuberculosis in Southern India.

    Science.gov (United States)

    Jenum, Synne; Selvam, Sumithra; Mahelai, Diana; Jesuraj, Nelson; Cárdenas, Vicky; Kenneth, John; Hesseling, Anneke C; Doherty, Timothy Mark; Vaz, Mario; Grewal, Harleen M S

    2014-10-01

    Reliable identification of Mycobacterium tuberculosis infection or tuberculosis (TB) disease in young children is vital to assure adequate preventive and curative treatment. The tuberculin skin test (TST) and IFNγ-release assays may supplement the diagnosis of pediatric TB as cases are typically bacteriologically unconfirmed. However, it is unclear to what extent the performance of TST and QuantiFERON-TB Gold In-Tube (QFT; Cellestis' IFNγ-release assay test) depends on the demographic, clinical and nutritional characteristics of children in whom they are tested. During a 2-year prospective observational study of 4382 neonates in Southern India, children with suspected TB were investigated and classified by a standard TB diagnostic algorithm. Clinical TB was diagnosed in 13 of 705 children referred for case verification with suspected TB. TST and QFT had a susceptibility for clinical TB of 31% and 23%, respectively, in this group. Children tuberculosis infection and more prone to indeterminate QFT results. TST was less reliable in children with wasting.

  13. Production of FR Tubing from Advanced ODS Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Maloy, Stuart Andrew [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lavender, Curt [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Omberg, Ron [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lewandowski, John [Case Western Reserve Univ., Cleveland, OH (United States)

    2016-10-25

    Significant research is underway to develop LWR nuclear fuels with improved accident tolerance. One of the leading candidate materials for cladding are the FeCrAl alloys. New alloys produced at ORNL called Gen I and Gen II FeCrAl alloys possess excellent oxidation resistance in steam up to 1400°C and in parallel methods are being developed to produce tubing from these alloys. Century tubing continues to produce excellent tubing from FeCrAl alloys. This memo reports receipt of ~21 feet of Gen I FeCrAl alloy tubing. This tubing will be used for future tests including burst testing, mechanical testing and irradiation testing.

  14. Thermal-hydraulic performance of oval tubes in a cross-flow of air

    Science.gov (United States)

    Hasan, Ala

    2005-06-01

    The thermal-hydraulic performance of five oval tubes is experimentally investigated and compared with that for a circular tube in a cross-flow of air. The range of Reynolds numbers ReD is approximately between 1,000 and 11,000. The nominal axis ratios R (major axis/minor axis) for three of the investigated oval tubes are 2, 3, and 4. Two other configurations of oval tubes are also tested, an oval tube R=3 with two wires soldered on its upper and lower top positions, and a cut-oval tube. The performance of the tubes is corrected for the effects of area blockage and turbulence intensity. The measurement results show that the mean Nusselt numbers NuD for the oval tubes are close to that for the circular tube for ReDthermal-hydraulic performance is indicated by the ratio NuD/Cd, which shows a better combined performance for the oval tubes.

  15. Solvothermal synthesis of Pt-Pd alloys with selective shapes and their enhanced electrocatalytic activities

    Science.gov (United States)

    Zhang, Zhi-Cheng; Hui, Jun-Feng; Guo, Zhen-Guo; Yu, Qi-Yu; Xu, Biao; Zhang, Xin; Liu, Zhi-Chang; Xu, Chun-Ming; Gao, Jin-Sen; Wang, Xun

    2012-03-01

    Pt-Pd bimetallic alloy nanostructures with highly selective morphologies such as cube, bar, flower, concave cube, and dendrite have been achieved through a facile one-pot solvothermal synthesis. The effects of shape-controllers (sodium dodecyl sulfate (SDS), ethylenediamine-tetraacetic acid disodium salt (EDTA-2Na), NaI) and solvents (water/DMF) on the morphologies were systematically investigated. The electrocatalytic activities of these Pt-Pd alloy nanostructures toward formic acid oxidation were tested. The results indicated that these alloy nanocrystals exhibited enhanced and shape-dependent electrocatalytic activity toward formic acid oxidation compared to commercial Pt black and Pt/C catalysts.Pt-Pd bimetallic alloy nanostructures with highly selective morphologies such as cube, bar, flower, concave cube, and dendrite have been achieved through a facile one-pot solvothermal synthesis. The effects of shape-controllers (sodium dodecyl sulfate (SDS), ethylenediamine-tetraacetic acid disodium salt (EDTA-2Na), NaI) and solvents (water/DMF) on the morphologies were systematically investigated. The electrocatalytic activities of these Pt-Pd alloy nanostructures toward formic acid oxidation were tested. The results indicated that these alloy nanocrystals exhibited enhanced and shape-dependent electrocatalytic activity toward formic acid oxidation compared to commercial Pt black and Pt/C catalysts. Electronic supplementary information (ESI) available: See DOI: 10.1039/c2nr12135b

  16. Measurement of the forming limit stress curve using a multi-axial tube expansion test with a digital image correlation system

    Science.gov (United States)

    Hakoyama, Tomoyuki; Kuwabara, Toshihiko

    2013-12-01

    A servo-controlled tension-internal pressure testing machine with an optical 3D deformation analysis system (ARAMIS) was used to measure the multi-axial plastic deformation behavior of a high-strength steel sheet for a range of strain from initial yield to fracture. The testing machine is capable of applying arbitrary principal stress or strain paths to a tubular specimen using an electrical, closed-loop servo-control system for axial force and internal pressure. Tubular specimens with an inner diameter of 44.6 mm were fabricated from a high-strength steel sheet with a tensile strength of 590 MPa and a thickness of 1.2 mm by roller bending and laser welding. Several linear and non-linear stress paths in the first quadrant of the stress space were applied to the tubular specimens in order to measure the forming limit curve (FLC) and forming limit stress curve (FLSC) of the as-received test material, in addition to the contours of plastic work and the directions of plastic strain rates. The contours of plastic work and the directions of plastic strain rates measured for the linear stress path experiments were compared with those calculated using selected yield functions in order to identify the most appropriate yield function for the test material. Moreover, a Marciniak-Kuczyński type (M-K) forming limit analysis was performed using the most appropriate yield function. The calculated and measured FLC and FLSC were compared in order to validate the M-K approach. The path-dependence of the FLC and FLSC was also investigated.

  17. Remote field eddy current technique for gap measurement of horizontal flux detector guide tube in pressurized heavy water reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Hoon; Jung, Hyun Kyu; Yang, Dong Ju; Cheong, Yong Moo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2004-11-15

    The fuel channels including the pressure tube(PT) and the calandria tube(CT) are important components of the pressurized heavy water reactor(PHWR). A sagging of fuel channel increases by heat and radiation exposure with the increasing operation time. The contact of fuel channel to the Horizontal flux Detector(HFD) guide tube is needed for the power plant safety. In order to solve this safety issue, the electromagnetic technique was applied to measure the status of the guide tube. The Horizontal flux Detector(HFD) guide tube and the Calandria tube(CT) in the Pressurized Heavy Water Reactor(PHWR) are cross-aligned horizontally. The remote field eddy current(RFEC) technology is applied for gap measurement between the HFD guide tube and the CT HFD guide tube can be detected by inserting the RFEC probe into pressure tube(PT) at the crossing point directly. The RFEC signals using the volume integral method(VIM) were simulated for obtaining the optimal inspection parameters. This paper shows that the simulated eddy current signals and the experimental results in variance with the CT/HFD gap.

  18. Laser weldability of Pt and Ti alloys

    Energy Technology Data Exchange (ETDEWEB)

    Noolu, N.J. [Center for Advanced Materials Joining, University of Waterloo, Waterloo (Canada)]. E-mail: nnoolu@mecheng1.uwaterloo.ca; Kerr, H.W. [Center for Advanced Materials Joining, University of Waterloo, Waterloo (Canada); Zhou, Y. [Center for Advanced Materials Joining, University of Waterloo, Waterloo (Canada); Xie, J. [Cardiac Rhythm Management Division, Street Jude Medical Inc., Sylmar, CA (United States)

    2005-04-25

    Crack susceptibility of laser spot welds between Pt and Ti alloys was studied by characterizing the surface and the cross-sections of the welds produced at different pulse energies. Increase in laser pulse energy increased the dilution by the Ti alloy, giving rise to the evolution of microstructures with varying Ti contents across the entire fusion zone. Hardness results showed that regions with 66-75% Ti, i.e. consisting of primary Ti{sub 3}Pt and/or Ti{sub 3}Pt + TiPt eutectic, have a hardness higher than 700 Vickers hardness numbers (VHN), while regions with 42-66% Ti, i.e. consisting of primary TiPt, possessed hardness between 400 and 700 VHN. The extent of cracking increased with the increase in pulse energy and the cracked regions consisted of Ti contents between 50 and 75%. Brittle cracking in microstructures consisting of Ti{sub 3}Pt and TiPt phases suggested that one or both of the constituent phases are susceptible to cracking. However, crack arrest in microstructures predominantly consisting of TiPt showed that Ti{sub 3}Pt is the most susceptible phase to cracking in Pt-Ti alloy welds.

  19. High-Speed Measurement of the Internal Diameter of Tubes: A Comparison of Methods

    DEFF Research Database (Denmark)

    Gundtoft, Hans Erik; Agerup, C.C.; Nielsen, N.

    1974-01-01

    The authors have compared various methods of tube measurement and have made the striking conclusion that the continuous measurement of the internal diameter of precision tubes with an air gauge is often useless in practice. The methods selected for experiment were all contactless and so included ...... with ultrasonic immersion testing for flaws to make a complete tube testing facility....

  20. CHARACTERIZATION OF ADDITIVE MANUFACTURING FOR PROCESS TUBING

    Energy Technology Data Exchange (ETDEWEB)

    Korinko, John S. [Savannah River National Laboratory (SRNL); BobbittIII, John T. [Savannah River National Laboratory (SRNL); Morgan, Michael J. [Savannah River National Laboratory (SRNL); Reigel, Marissa [Savannah River National Laboratory (SRNL); List III, Frederick Alyious [ORNL; Babu, Suresh S. [University of Tennessee (UTK) and Oak Ridge National Laboratory (ORNL)

    2016-01-01

    Additive Manufacturing has garnered significant levels of interest in recent years as a primary manufacturing method. While the general technology has been around for over 20 years, with increased computing capacity, higher powered directed energy sources, e.g., lasers and electron beams, it is coming of age as a viable technique for high value added, low production quantity components. The Savannah River National Laboratory is interested in AM as a technique to build hydrogen isotope separation components called Thermal Cycling Absorption Process (TCAP) columns. The TCAP operates from cryogenic to moderate temperatures in a cyclic manner and is a pressure boundary. The current technique for fabricating TCAP columns is to form a flat coil of 0.375 to 0.5 inch diameter tube and braze two coils together. During the brazing operation, the two nested coils often move and this movement results in gaps between the coils. Since one coil contains the working fluid, i.e., liquid nitrogen, and the other the process fluid, hydrogen isotopes, these gaps result in poor heat transfer. Additive manufacturing is being explored as a replacement technology since the adjacent tubes can be fabricated simultaneously and in intimate contact and they can also share a common wall to improve heat transfer. AM allows designers to develop unique tube structures that overcome several of the shortcomings of the coil and braze technique, such as the braze gap in fabrication and slow cooling during operation. Simple test samples with various internal geometries were designed and built from Type 316L stainless steel using a laser powder bed process. Three test article geometries that were built include a simple tube, a pair of stacked tubes, and a tube partially surrounded by two kidney shaped tubes with cooling fins that would extend into the process fluid, these tube sections incorporated thermowells or heat trace channels, selectively. The test samples will be subjected to heat transfer

  1. Proficiency of European official control laboratories in the determination of authorized carotenoids in animal feed - EURL for Feed Additives Control PT exercise 2015 and annual workshop

    OpenAIRE

    Vincent, Ursula; SERANO Federica; Von Holst, Christoph

    2016-01-01

    The European Union Reference Laboratory for Feed additives, has been mandated by the Directorate General for Health and Food Safety to organise a proficiency test (PT) among appointed National Reference Laboratories (NRLs). The aim of the PT was to assess the capacity of the NRLs to correctly determine selected authorised carotenoids in feed matrices at authorised levels. This report presents the results of the PT. Eight laboratories from eight countries registered to this 2015 PT exercise an...

  2. Low Pt content direct methanol fuel cell anode catalyst: nanophase PtRuNiZr

    Science.gov (United States)

    Narayanan, Sekharipuram R. (Inventor); Whitacre, Jay F. (Inventor)

    2010-01-01

    A method for the preparation of a metallic material having catalytic activity that includes synthesizing a material composition comprising a metal content with a lower Pt content than a binary alloy containing Pt but that displays at least a comparable catalytic activity on a per mole Pt basis as the binary alloy containing Pt; and evaluating a representative sample of the material composition to ensure that the material composition displays a property of at least a comparable catalytic activity on a per mole Pt basis as a representative binary alloy containing Pt. Furthermore, metallic compositions are disclosed that possess substantial resistance to corrosive acids.

  3. Mechanical properties of ceramic composite tubes

    Energy Technology Data Exchange (ETDEWEB)

    Curtin, W.A.; Oleksuk, L.L.; Reifsnider, K.L. [Virginia Polytechnic Inst. and State Univ., Blacksburg, VA (United States); Stinton, D.P. [Oak Ridge National Lab., TN (United States)

    1995-08-01

    Results of axial tension tests on SiC/SiC tubular ceramic composite components fabricated by a forced-M technique are presented. Axial elastic modulus measurements on a number of tubes show that the Young`s modulus varies along the length of the tube, with occasional very stiff or very soft regions. Tests to failure on a few tubes show the initiation of non-linear stress-strain behavior to be in the range of 3-9 ksi, followed by extensive non-linear deformation up to failure. For one tube, the failure stress obtained was 20.1 ksi, but the strains to failure at various axial locations varies from 0.19%to 0.24%. The correlation between modulus and proportional limit is considered within the ACK matrix cracking theory and within a model in which matrix cracking between fiber tows occurs, both modified to account for matrix porosity. The crack size required to cause stress concentrations large enough to cause failure at the observed strength is considered. Predictions for both matrix cracking and strength suggest that the current generation of tubes are controlled by microstructural defects.

  4. Experiments with micro-fin tube in single phase

    Energy Technology Data Exchange (ETDEWEB)

    Copetti, J.B.; Macagnan, M.H.; De Souza, D.; Oliveski, R.D.C. [Universidade do Vale do Rio dos Sinos, Sao Leopoldo (Brazil). Department of Mechanical Engineering

    2004-12-01

    This work shows heat transfer and friction characteristics for water single-phase flow in micro-fin tubes. The analysis of thermal and hydraulic behavior from a laminar to a turbulent flow was carried out in an experimental setup with a 9.52 mm diameter micro-fin tube. The tube was wrapped up with an electrical resistance tape to supply a constant heat flux to its surface. Different operational conditions were considered in the heating tests. The inlet and outlet temperatures, differential wall temperatures along the tube, pressure drop and flow rate were measured. The relationships of heat flux and flow rate with heat transfer coefficient and pressure drop were analyzed. Under the same conditions, comparative experiments with an internally smooth tube were conducted. The micro-fin tube provides higher heat transfer performance than the smooth tube (in turbulent flow h{sub micro-fin}/h{sub smooth}=2.9). In spite of the increase in pressure drop ({delta}p{sub micro-fin}/{delta}p{sub smooth}=1.7) the heat transfer results were significantly higher (about 80%). This shows the advantages of this enhanced configuration in thermal performance related to conventional tubes. The smooth tube results were validated by the comparison with the Dittus-Boelter and Gnielinski correlations. For the micro-fin tube an empirical correlation to the heat transfer coefficient adjusted from the set of measured data is proposed. The values obtained are in conformity with experimental results. (author)

  5. Heat-shrink plastic tubing seals joints in glass tubing

    Science.gov (United States)

    Del Duca, B.; Downey, A.

    1968-01-01

    Small units of standard glass apparatus held together by short lengths of transparent heat-shrinkable polyolefin tubing. The tubing is shrunk over glass O-ring type connectors having O-rings but no lubricant.

  6. Specific adsorption of perchlorate anions on Pt{hkl} single crystal electrodes.

    Science.gov (United States)

    Attard, Gary A; Brew, Ashley; Hunter, Katherine; Sharman, Jonathan; Wright, Edward

    2014-07-21

    The voltammetry of Pt{111}, Pt{100}, Pt{110} and Pt{311} single crystal electrodes as a function of perchloric acid concentration (0.05-2.00 M) has been studied in order to test the assertion made in recent reports by Watanabe et al. that perchlorate anions specifically adsorb on polycrystalline platinum. Such an assertion would have significant ramifications for our understanding of electrocatalytic processes at platinum surfaces since perchlorate anions at low pH have classically been assumed not to specifically adsorb. For Pt{111}, it is found that OHad and electrochemical oxide states are both perturbed significantly as perchloric acid concentration is increased. We suggest that this is due to specific adsorption of perchlorate anions competing with OHad for adsorption sites. The hydrogen underpotential deposition (H UPD) region of Pt{111} however remains unchanged although evidence for perchlorate anion decomposition to chloride on Pt{111} is reported. In contrast, for Pt{100} no variation in the onset of electrochemical oxide formation is found nor any shift in the potential of the OHad state which normally results from the action of specifically adsorbing anions. This suggests that perchlorate anions are non-specifically adsorbed on this plane although strong changes in all H UPD states are observed as perchloric acid concentration is increased. This manifests itself as a redistribution of charge from the H UPD state situated at more positive potential to the one at more negative potential. For Pt{110} and Pt{311}, marginal changes in the onset of electrochemical oxide formation are recorded, associated with specific adsorption of perchlorate. Specific adsorption of perchlorate anions on Pt{111} is deleterious to electrocatalytic activity in relation to the oxygen reduction reaction (ORR) as measured using a rotating disc electrode (RDE) in a hanging meniscus configuration. This study supports previous work suggesting that a large component of the ORR

  7. Downhole pulse tube refrigerators

    Energy Technology Data Exchange (ETDEWEB)

    Swift, G.; Gardner, D. [Los Alamos National Lab., NM (United States). Condensed Matter and Thermal Physics Group

    1997-12-01

    This report summarizes a preliminary design study to explore the plausibility of using pulse tube refrigeration to cool instruments in a hot down-hole environment. The original motivation was to maintain Dave Reagor`s high-temperature superconducting electronics at 75 K, but the study has evolved to include three target design criteria: cooling at 30 C in a 300 C environment, cooling at 75 K in a 50 C environment, cooling at both 75 K and 30 C in a 250 C environment. These specific temperatures were chosen arbitrarily, as representative of what is possible. The primary goals are low cost, reliability, and small package diameter. Pulse-tube refrigeration is a rapidly growing sub-field of cryogenic refrigeration. The pulse tube refrigerator has recently become the simplest, cheapest, most rugged and reliable low-power cryocooler. The authors expect this technology will be applicable downhole because of the ratio of hot to cold temperatures (in absolute units, such as Kelvin) of interest in deep drilling is comparable to the ratios routinely achieved with cryogenic pulse-tube refrigerators.

  8. The thermal tube

    Energy Technology Data Exchange (ETDEWEB)

    Semena, M.G.

    1980-08-30

    A thermal tube is proposed which contains a layer of dielectric, capillary porous material located on the internal surface of the body. To increase the heat transmitting capability, the layer of capillary porous material is made in the form of a felting, formed by hollow fibers from a non-alkaline, borosilicate glass.

  9. Prawns in Bamboo Tube

    Institute of Scientific and Technical Information of China (English)

    1998-01-01

    Ingredients: 400 grams Jiwei prawns, 25 grams pork shreds, 5 grams sliced garlic. Condiments: 5 grams cooking oil, minced ginger root and scallions, cooking wine, salt, pepper and MSG (optional) Method: 1. Place the Shelled prawns into a bowl and mix with all the condiments. 2. Stuff the prawns into a fresh bamboo tube,

  10. Cladding tube manufacturing technology

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, R. [Kraftwerk Union AG, Mulheim (Germany); Jeong, Y.H.; Baek, B.J.; Kim, K.H.; Kim, S.J.; Choi, B.K.; Kim, J.M. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1999-04-01

    This report gives an overview of the manufacturing routine of PWR cladding tubes. The routine essentially consists of a series of deformation and annealing processes which are necessary to transform the ingot geometry to tube dimensions. By changing shape, microstructure and structure-related properties are altered simultaneously. First, a short overview of the basics of that part of deformation geometry is given which is related to tube reducing operations. Then those processes of the manufacturing routine which change the microstructure are depicted, and the influence of certain process parameters on microstructure and material properties are shown. The influence of the resulting microstructure on material properties is not discussed in detail, since it is described in my previous report 'Alloy Development for High Burnup Cladding.' Because of their paramount importance still up to now, and because manufacturing data and their influence on properties for other alloys are not so well established or published, the descriptions are mostly related to Zry4 tube manufacturing, and are only in short for other alloys. (author). 9 refs., 46 figs.

  11. Misdirected Minitracheostomy Tube

    Science.gov (United States)

    Singh, Ajmer; Nanda, Chinmaya; Mehta, Yatin

    2017-01-01

    We report a patient who after an uneventful coronary artery bypass graft surgery and left ventricular aneurysmorrhaphy developed intracerebral hemorrhage and subsequently required minitracheostomy. Chest X-ray showed misdirected minitracheostomy tube facing upward toward the laryngeal opening which was repositioned using bronchoscope. PMID:28074805

  12. Misdirected minitracheostomy tube

    Directory of Open Access Journals (Sweden)

    Ajmer Singh

    2017-01-01

    Full Text Available We report a patient who after an uneventful coronary artery bypass graft surgery and left ventricular aneurysmorrhaphy developed intracerebral hemorrhage and subsequently required minitracheostomy. Chest X-ray showed misdirected minitracheostomy tube facing upward toward the laryngeal opening which was repositioned using bronchoscope.

  13. Heat transfer to finned tubes exposed to hot waste gas

    Energy Technology Data Exchange (ETDEWEB)

    Scholand, E.; Kremer, H.

    1975-05-01

    Transfer of heat by forced convection to finned tubes, particularly to those with an elliptical center pipe, is described. These pipes are used in gas-fired water heaters, boilers, and heat exchangers. Finned tubes in a test tunnel were exposed to a stream of waste gas from a gas/air mixture at different Reynolds numbers. Mathematical relationships showing the dependence of the Nusselt number on the Reynolds number and on the geometry of the tubes were derived. The single pipe showed a significant drop in the heat-transfer coefficient as the gap between fins became closer. The results of the measurement of heat transfer by forced convection to finned tubes were expressed in a standard form for all tubes. The same heat transfer law can be applied to electrically heated finned tubes exposed to a stream of cooling air.

  14. Vertical, Bubbly, Cross-Flow Characteristics over Tube Bundles

    Science.gov (United States)

    Iwaki, C.; Cheong, K. H.; Monji, H.; Matsui, G.

    2005-12-01

    Two-phase flow over tube bundles is commonly observed in shell and tube-type heat exchangers. However, only limited amount of data concerning flow pattern and void fraction exists due to the flow complexity and the difficulties in measurement. The detailed flow structure in tube bundles needs to be understood for reliable and effective design. Therefore, the objective of this study was to clarify the two-phase structure of cross-flow in tube bundles by PIV. Experiments were conducted using two types of models, namely in-line and staggered arrays with a pitch-to-diameter ratio of 1.5. Each test section contains 20 rows of five 15 mm O.D. tubes in each row. The experiment’s data were obtained under very low void fraction (αtube bundles were described in terms of the velocity vector field, turbulence intensity and void fraction.

  15. A second-generation constrained reaction volume shock tube.

    Science.gov (United States)

    Campbell, M F; Tulgestke, A M; Davidson, D F; Hanson, R K

    2014-05-01

    We have developed a shock tube that features a sliding gate valve in order to mechanically constrain the reactive test gas mixture to an area close to the shock tube endwall, separating it from a specially formulated non-reactive buffer gas mixture. This second-generation Constrained Reaction Volume (CRV) strategy enables near-constant-pressure shock tube test conditions for reactive experiments behind reflected shocks, thereby enabling improved modeling of the reactive flow field. Here we provide details of the design and operation of the new shock tube. In addition, we detail special buffer gas tailoring procedures, analyze the buffer/test gas interactions that occur on gate valve opening, and outline the size range of fuels that can be studied using the CRV technique in this facility. Finally, we present example low-temperature ignition delay time data to illustrate the CRV shock tube's performance.

  16. A second-generation constrained reaction volume shock tube

    Science.gov (United States)

    Campbell, M. F.; Tulgestke, A. M.; Davidson, D. F.; Hanson, R. K.

    2014-05-01

    We have developed a shock tube that features a sliding gate valve in order to mechanically constrain the reactive test gas mixture to an area close to the shock tube endwall, separating it from a specially formulated non-reactive buffer gas mixture. This second-generation Constrained Reaction Volume (CRV) strategy enables near-constant-pressure shock tube test conditions for reactive experiments behind reflected shocks, thereby enabling improved modeling of the reactive flow field. Here we provide details of the design and operation of the new shock tube. In addition, we detail special buffer gas tailoring procedures, analyze the buffer/test gas interactions that occur on gate valve opening, and outline the size range of fuels that can be studied using the CRV technique in this facility. Finally, we present example low-temperature ignition delay time data to illustrate the CRV shock tube's performance.

  17. Comparative study of ethanol oxidation at Pt: Based nanoalloys and UPD modified Pt nanoparticles

    Directory of Open Access Journals (Sweden)

    Tripković Amalija V.

    2010-01-01

    Full Text Available The activity of two alloys, Pt3Sn/C and Pt3Ru2/C, was compared with the activity of Pt/C modified with corresponding amounts of SnUPD (≈25 % and RuUPD (≈40 % in oxidation of ethanol. Pt3Sn/C, Pt3Ru2/C and Pt/C catalysts were characterized by XRD. To establish the activity and stability of the catalysts, potentiodynamic, quasi steady-state and chronoamperometric measurements were performed. Both alloys are more active than SnUPD or RuUPD modified Pt/C catalysts. Electronic effect determining dominantly the activity of Pt3Sn/C is the main reason for its higher activity compared to Pt3Ru2/C. Since SnUPD and RuUPD do not provoke any significant modification of electronic environment, both modified Pt/C catalysts are less active than corresponding alloys. More pronounced difference in activity between Pt3Sn/C and SnUPD modified Pt/C than between Pt3Ru2/C and RuUPD modified Pt/C is caused by electronic effect in Pt3Sn/C. High activity of Pt3Sn/C modified with small amount of SnUPD (≈10% can be explained by combining the electronic effect, causing less strongly bonded adsorbate on Pt sites and easier mobility of SnUPD, with enhanced amount of oxygen-containing species on Sn sites resulting finally in reinforcement of bifunctional mechanism.

  18. Expanding access to HIV viral load testing: a systematic review of RNA stability in EDTA tubes and PPT beyond current time and temperature thresholds.

    Science.gov (United States)

    Bonner, Kimberly; Siemieniuk, Reed A; Boozary, Andrew; Roberts, Teri; Fajardo, Emmanuel; Cohn, Jennifer

    2014-01-01

    HIV viral load (VL) testing is the gold standard for antiretroviral treatment monitoring, but many barriers exist to VL testing in resource-limited settings, including storage and transport limitations for whole blood and plasma. Data from various studies indicate that HIV RNA is stable beyond current recommendations. We conducted a systematic review to assess stability data of HIV RNA in whole blood and plasma across times and temperatures. Using a pre-defined protocol, five databases were searched for studies where blood samples from HIV patients were stored at time and temperature points that exceeded manufacturer recommendations. RNA stability, the primary outcome, was measured by the difference in means compared to samples stored within established thresholds. RNA stability was defined as ≤0.5 log degradation. The search identified 10,716 titles, of which nine full-text articles were included for review. HIV RNA maintained stability in EDTA whole blood and plasma at all measured time points up to 168 hours when stored at 4°C, while stability was detected at 72 hours (95% confidence) in whole blood at 25°C, with data points before and beyond 72 hours suggesting stability but not reaching statistical significance. For EDTA plasma stored at 30°C, stability was maintained up to 48 hours (95% confidence), with OLS linear regression estimates up to 127 hours, suggesting stability. Overall, quality of studies was moderate. Limitations included small sample sizes, few studies meeting inclusion criteria, and no studies examining RNA stability in low viremia (PPT in field conditions are needed.

  19. Electrodeposited Pt and Pt-Sn nanoparticles on Ti as anodes for direct methanol fuel cells

    Institute of Scientific and Technical Information of China (English)

    Hanaa B HASSAN

    2009-01-01

    Electro-oxidation of methanol was studied on titanium supported nanocrystallite Pt and Ptx-Sny catalysts prepared by electrodeposition techniques. Their electro-catalytic activities were studied in 0.5mol/L H2SO4 and compared to those of a smooth Pt, Pt/Pt and Pt-Sn/Pt electrodes. Platinum was deposited on Ti by galvanostatic and potentiostatic techniques. X-ray diffractometer (XRD) and energy dispersive X-ray (EDX) techniques were applied in order to investigate the chemical composition and the phase structure of the modified electrodes. Scanning electron microscopy (SEM) was used to characterize the surface morphology and to correlate the results obtained from the two electrochemical deposition methods. Results show that modified Pt/Ti electrodes prepared by the two methods have comparable performance and enhanced catalytic activity towards methanol electro-oxidation compared to Pt/Pt and smooth Pt electrodes. Steady state Tafel plots experiments show a higher rate of methanol oxidation on a Pt/Ti catalyst than that on a smooth Pt. Introduction of a small amount of Sn deposited with Pt improves the catalytic activity and the stability of prepared electrode with time as indicated from the cyclic votlammetry and the chronoamperometric experiments. The effect of variations in the composition for binary catalysts of the type Ptx-Sny/Ti towards the methanol oxidation reaction is reported. Consequently, the Ptx-Sny/Ti (x∶y (8∶1), molar ratio) catalyst is a very promising one for methanol oxidation.

  20. Steam reforming of glycerol over Pt-MCM-41 synthesized in a one-step process

    Science.gov (United States)

    Zhang, Xiao-Hui; Yan, Feng-Wen; Guo, Cun-Yue; Yuan, Guo-Qing

    2012-12-01

    Pt-MCM-41 materials were synthesized by a simple method via simultaneous self-assembling and Pt incorporation using cetyltrimethylammonium chloride (CTAC) as a structure directing agent. Structural characterization of the sample was carried out by N2 sorption, XRD and TEM measurements. The highly ordered structure of MCM-41 was not appreciably affected by the formation of the Pt particles. Unlike related results, the Pt nanoparticles were incorporated into the mesopores and embedded into the pore walls as framework. The Pt-MCM-41 sample was tested as a catalyst in the steam reforming of glycerol in which it exhibited moderate activity, high selectivity to hydrogen, and very low selectivity to light alkanes.

  1. Characterization of ultrafine-grained aluminum tubes processed by Tube Cyclic Extrusion–Compression (TCEC)

    Energy Technology Data Exchange (ETDEWEB)

    Babaei, A., E-mail: A_babaei@ut.ac.ir; Mashhadi, M.M.

    2014-09-15

    Tube Cyclic Extrusion–Compression as a novel severe plastic deformation technique for tubes was utilized for processing ultrafine grained 1050 aluminum alloy for the first time. In this method, aluminum tube is fully constrained and deformed between mandrel and chamber with a small neck zone. The material deformation during Tube Cyclic Extrusion–Compression processing analyzed and the grain refinement mechanism were described. The capability of Tube Cyclic Extrusion–Compression in grain refinement of the aluminum alloy was demonstrated by transmission electron microscopy observations and X-ray diffraction line profile analysis. The micrographs of the evolved microstructure show grain size of 850 nm and 550 nm after the first and second processing cycles of Tube Cyclic Extrusion–Compression, respectively. Mechanical properties of the initial and processed specimens were extracted from ring-hoop tensile tests. The documented results confirm grain refinement by showing remarkable increase in the yield and ultimate strengths. The main increase in strength and decrease in elongation take place after the first cycle. The microhardness assessments illustrate increase from the initial value of 29 Hv to 44 and 49 Hv respectively after the first and second cycles of Tube Cyclic Extrusion–Compression. There is a good homogeneity in peripheral microhardness and microhardness across the tube thickness. - Highlights: • Tubes of AA1050 for the first time were successfully SPD processed by TCEC. • The grain size was refined to 550 nm after two cycles of TCEC. • Notable increase in the strength and decrease in the elongation were documented. • The microhardness increased to 49 Hv from the initial value of 29 Hv. • Good homogeneity in the microhardness distribution was recorded.

  2. Restore condition of Incore thimble tubes in guide tubes

    Energy Technology Data Exchange (ETDEWEB)

    Solanas, A.; Izquierdo, J.

    2014-07-01

    Aging of Nuclear Power Plant and succession of outages lead to wear and twist of the thimbles tubes but also to the fooling of Incore guide tubes. These can create friction and a high strength must be used for thimble tubes withdrawal. (Author)

  3. Development and formability analysis of TRIP seamless steel tube

    Institute of Scientific and Technical Information of China (English)

    Zhang Zicheng; Zhu Fuxian

    2014-01-01

    In this paper,the production technology of transformation induced plasticity (TRIP) steel was first introduced into the steel tube manufacture field to produce the steel tubes with high strength and plasticity. The TRIP seamless steel tubes with the microstructure of ferrite,bainite,retained austenite and a little martensite were successfully fabricated using a cold-drawn steel tube with two-stage heat treatment technique and continu-ous heat treatment process,respectively. The ring tensile test and cold bend test were carried out to study the formability of the newly developed TRIP seamless steel tube. The results showed that the TRIP seamless steel tubes have a good cold formability,and they are available to be used in the tube hydroforming process. In ad-dition,the equipment of continuous heat treatment developed in the current study can be used to produce TRIP steel tube,and it may serve as an important reference for the industrial production of TRIP steel tube.

  4. Designing a feedback control algorithm for the tube hydroforming process

    DEFF Research Database (Denmark)

    Endelt, Benny Ørtoft; Cheng, Ming; Zhang, Shihong

    2013-01-01

    to the dynamic behavior of the system and the numerical tests show that it is possible to control the quality and plastic deformation of the tube. Numerical simulations show that the control system can eliminate both rupture and irreversible wrinkling - which are the two major failure modes in tube hydroforming....

  5. Alignment of the drift tube detector at the neutrino oscillation experiment OPERA; Alignment des Driftroehrendetektors am Neutrino-Oszillationsexperiment OPERA

    Energy Technology Data Exchange (ETDEWEB)

    Goellnitz, Christoph

    2012-09-15

    The present thesis was composed during the course of the OPERA experiment, which aims to give a direct evidence for neutrino oscillations in the channel {nu}{sub {mu}} {yields} {nu}{sub {tau}}. The OPERA detector is designed to observe the appearance of tau neutrinos in an originally pure muon neutrino beam, the CNGS beam. As important part of the detector the precision tracker (PT), a drift tube detector, consists of 9504 drift tubes in 198 modules. In this thesis, several parts of the slow control of the PT are developed and implemented to ensure operation during data taking over several years. The main part is the geometric calibration, the alignment of the detector. The alignment procedure contains both hardware and software parts, the software methods are developed and applied. Using straight particle tracks, the detector components are geometrically corrected. A special challenge for the alignment for the PT is the fact that at this kind of low-rate experiment only a small number of particle tracks is available. With software-based corrections of the module rotation, a systematic error of 0.2 mrad has been attained, for corrections of translation, a systematic error of 32 {mu}m is reached. For the alignment between two adjacent PT walls, the statistical error is less than 8 {mu}m. All results of the position monitoring system are considered. All developed methods are tested with Monte Carlo simulations. The detector requirements ({Delta}p/p {<=} 0.25 below 25 GeV) are met. The analysis of the momentum measurement for high energies above 25 GeV demonstrates the resulting improvement. The mean momentum is falling significantly using the new alignment values. The significance of the detector alignment becomes most evident in the analysis of cosmic particles. The muon charge ratio R{sub {mu}} is expected not to be angular dependent. The {chi}{sup 2} probability of the measured distribution improves up to 58%. The muon charge ratio was also investigated in

  6. Nonlinear seismic response analysis of reinforced concrete tube in tube structure

    Institute of Scientific and Technical Information of China (English)

    WANG Hai-bo; SHEN Pu-sheng

    2005-01-01

    Super-highly reinforced concrete tube in tube structure is a developing structure system of high-rise building. The more reasonable derivation process of the multi-vertical-line-element model stiffness matrix is given.On the premise of pointing out the problems of present multi-spring element model, combined with present multivertical-line-element model for analyzing on shear wall, the model is expanded to spatial one, and the stiffness matrix of which is derived. Combined with hysteretic axial model and hysteretic shear model, it is suitable for columns,wall limbs and beams with all kinds of section form. Some examples are calculated and compared with test results,which shows that the models have relatively good accuracy. On the base of the experimental phenomenon and failure mechanism for tube in tube structure specimen, nonlinear seismic responses analysis program on the basis of the advantaged element model for tube in tube structure is developed. Calculation results are in good agreement with those of the pseudo-dynamic tests and the failure mechanism can be well reflected.

  7. Enrichment Monitor for 235U Fuel Tubes

    Energy Technology Data Exchange (ETDEWEB)

    Winn, W.G.

    2001-08-22

    This report describes the performance of this prototype y-monitor of 235 Uranium enrichment. In this proposed method y-rates associated with 235U and 232U are correlated with enrichment. Instrumentation for appraising fuel tubes with this method has been assembled and tested.

  8. Kinetic limitations in surface alloy formation: PtCu/Ru(0001)

    Science.gov (United States)

    Engstfeld, A. K.; Jung, C. K.; Behm, R. J.

    2016-01-01

    We have systematically investigated the structure and structure formation of two-dimensional PtCu monolayer surface alloys on Ru(0001) as model systems for bimetallic PtCu catalysts and surfaces by scanning tunneling microscopy (STM). The surface alloys were prepared by deposition of Pt and Cu on Ru(0001) and thermal intermixing; different procedures were developed and tested to produce bimetallic surfaces with homogeneous structure, including also a homogeneous distribution of the different surface species, while at the same time intermixing with the Ru(0001) substrate should be inhibited. STM imaging revealed that for Pt concentrations below 65% surface alloys with homogeneous distribution could be formed, while at higher concentrations in the mixed phase, up to 82%, pure Pt or Pt-rich surface areas were formed as well. At Pt contents of 0.20 0.65 line structures were observed, but of different nature. The distribution of surface atoms in the mixed phase was evaluated from STM images with chemical contrast, the related short-range order parameters were determined. The resulting structures and their energetics, the influence of different deposition and annealing procedures and the suitability of these surfaces as model systems for studies of the surface chemistry of bimetallic PtCu surfaces are discussed.

  9. High-performance core-shell PdPt@Pt/C catalysts via decorating PdPt alloy cores with Pt

    Science.gov (United States)

    Wu, Yan-Ni; Liao, Shi-Jun; Liang, Zhen-Xing; Yang, Li-Jun; Wang, Rong-Fang

    A core-shell structured low-Pt catalyst, PdPt@Pt/C, with high performance towards both methanol anodic oxidation and oxygen cathodic reduction, as well as in a single hydrogen/air fuel cell, is prepared by a novel two-step colloidal approach. For the anodic oxidation of methanol, the catalyst shows three times higher activity than commercial Tanaka 50 wt% Pt/C catalyst; furthermore, the ratio of forward current I f to backward current I b is high up to 1.04, whereas for general platinum catalysts the ratio is only ca. 0.70, indicating that this PdPt@Pt/C catalyst has high activity towards methanol anodic oxidation and good tolerance to the intermediates of methanol oxidation. The catalyst is characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), and X-ray photoelectron spectroscopy (XPS). The core-shell structure of the catalyst is revealed by XRD and TEM, and is also supported by underpotential deposition of hydrogen (UPDH). The high performance of the PdPt@Pt/C catalyst may make it a promising and competitive low-Pt catalyst for hydrogen fueled polymer electrolyte membrane fuel cell (PEMFC) or direct methanol fuel cell (DMFC) applications.

  10. $\\mathcal{PT}$-symmetric mode-locking

    CERN Document Server

    Longhi, Stefano

    2016-01-01

    Parity-time ($\\mathcal{PT}$) symmetry is one of the most important accomplishments in optics over the past decade. Here the concept of $\\mathcal{PT}$ mode-locking of a laser is introduced, in which active phase locking of cavity axial modes is realized by asymmetric mode coupling in a complex time crystal. $\\mathcal{PT}$ mode-locking shows a transition from single to double pulse emission as the $\\mathcal{PT}$ symmetry breaking point is crossed. The transition can show a turbulent behavior, depending on a dimensionless modulation parameter that plays the same role as the Reynolds number in hydrodynamic flows.

  11. Low content Pt nanoparticles anchored on N-doped reduced graphene oxide with high and stable electrocatalytic activity for oxygen reduction reaction

    Science.gov (United States)

    Li, Zeyu; Gao, Qiuming; Zhang, Hang; Tian, Weiqian; Tan, Yanli; Qian, Weiwei; Liu, Zhengping

    2017-01-01

    A novel kind of Pt/N-rGO hybrid possessing of low content 5.31 wt.% Pt anchored on the surface of nitrogen doped reduced graphene oxide (N-rGO) evenly was prepared. The Pt has uniformed 2.8 nm diameter and exposed (111) crystal planes; meanwhile, the N works as the bridge between Pt and rGO with the Pt-N and N-C chemical bonds in Pt/N-rGO. The Pt/N-rGO material has a very high electrocatalytic activity in oxygen reduction reaction with the mass catalytic activity more than 1.5 times of the commercial Pt/C due to the synergistic catalytic effect of both N-doped carbon matrix and Pt nanoparticles. Moreover, the Pt/N-rGO exhibits an excellent stability with hardly loss (only 0.4%) after accelerated durability tests of 5000 cycles based on the stable Pt-N-C chemical bonds in Pt/N-rGO, which can prevent the detachment, dissolution, migration and aggregation of Pt nanoparticles on the matrix during the long-term cycling. PMID:28233857

  12. Low content Pt nanoparticles anchored on N-doped reduced graphene oxide with high and stable electrocatalytic activity for oxygen reduction reaction

    Science.gov (United States)

    Li, Zeyu; Gao, Qiuming; Zhang, Hang; Tian, Weiqian; Tan, Yanli; Qian, Weiwei; Liu, Zhengping

    2017-02-01

    A novel kind of Pt/N-rGO hybrid possessing of low content 5.31 wt.% Pt anchored on the surface of nitrogen doped reduced graphene oxide (N-rGO) evenly was prepared. The Pt has uniformed 2.8 nm diameter and exposed (111) crystal planes; meanwhile, the N works as the bridge between Pt and rGO with the Pt-N and N-C chemical bonds in Pt/N-rGO. The Pt/N-rGO material has a very high electrocatalytic activity in oxygen reduction reaction with the mass catalytic activity more than 1.5 times of the commercial Pt/C due to the synergistic catalytic effect of both N-doped carbon matrix and Pt nanoparticles. Moreover, the Pt/N-rGO exhibits an excellent stability with hardly loss (only 0.4%) after accelerated durability tests of 5000 cycles based on the stable Pt-N-C chemical bonds in Pt/N-rGO, which can prevent the detachment, dissolution, migration and aggregation of Pt nanoparticles on the matrix during the long-term cycling.

  13. A helium liquefier using three 4 k pulse tube cryocoolers

    Science.gov (United States)

    Wang, Chao; Oviedo, Abner

    2012-06-01

    We have developed a helium liquefier which can be used for recondensing/reliquefying helium vapor in a helium cryostat or liquefying helium gas in a storage dewar. The helium liquefier employs three 4 K pulse tube cryocoolers, Cryomech model PT415. Each PT415 has remote motor/rotary valve assembly to minimize vibration, providing ≥ 1.5W at 4.2K. The liquefier can liquefy room temperature helium gas with a liquefaction rate of 62 Liter/day. When installing it in the cryostat, it can recondense and reliquefy helium vapor with a rate of 78 L/day. The liquefier will be installed in a gravitational wave detector in Brazil to recondense/reliquefy the helium boil off from the cryostat.

  14. Condensate Accretion in Shock Tube's Expansion Fan

    Science.gov (United States)

    Mezonlin, Ephrem-Denis; DeSilva, Upul P.; Hunte, F.; Johnson, Joseph A., III

    1997-01-01

    It has been shown that turbulence and temperature influence the droplet sizes in expansion fan induced condensation by studying the Rayleigh scattering from one port in our shock tube's test section. We have modified our set-up so as to allow, using two ports, the real time measurement of the influence of turbulence and temperature on the rate at which these droplets grow. To do this, we looked at the Rayleigh scattering from two different ports for ten Reynolds numbers at five different temperatures. We modeled the time of flight of droplets, using the equations of one-dimensional gas dynamics and the measured shock wave speed in shock tube's driven section.

  15. Remarks on the PT-pseudo-norm in PT-symmetric quantum mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Duc Tai Trinh [Department of Mathematics, Teacher Training College of Dalat, 29 Yersin, Dalat (Viet Nam)]|[Abdus Salam International Centre for Theoretical Physics, Strada Costiera 11, Trieste 34014 (Italy)

    2005-04-22

    This paper presents an underlying analytical relationship between the PT-pseudo-norm associated with the PT-symmetric Hamiltonian H = p{sup 2} + V(q) and the Stokes multiplier of the differential equation corresponding to this Hamiltonian. We show that the sign alternation of the PT-pseudo-norm, which has been observed as a generic feature of the PT-inner product, is essentially controlled by the derivative of a Stokes multiplier with respect to the eigenparameter.

  16. Enteral Tube Feeding and Pneumonia

    Science.gov (United States)

    Gray, David Sheridan; Kimmel, David

    2006-01-01

    To determine the effects of enteral tube feeding on the incidence of pneumonia, we performed a retrospective review of all clients at our institution who had gastrostomy or jejunostomy tubes placed over a 10-year period. Ninety-three subjects had a history of pneumonia before feeding tube insertion. Eighty had gastrostomy and 13, jejunostomy…

  17. CO Sensing Performance of a Micro Thermoelectric Gas Sensor with AuPtPd/SnO₂ Catalyst and Effects of a Double Catalyst Structure with Pt/α-Al₂O₃.

    Science.gov (United States)

    Goto, Tomoyo; Itoh, Toshio; Akamatsu, Takafumi; Shin, Woosuck

    2015-12-15

    The CO sensing properties of a micro thermoelectric gas sensor (micro-TGS) with a double AuPtPd/SnO₂ and Pt/α-Al₂O₃ catalyst were investigated. While several nanometer sized Pt and Pd particles were uniformly dispersed on SnO₂, the Au particles were aggregated as particles measuring >10 nm in diameter. In situ diffuse reflectance Fourier transform Infrared spectroscopy (DRIFT) analysis of the catalyst showed a CO adsorption peak on Pt and Pd, but no clear peak corresponding to the interaction between CO and Au was detected. Up to 200 °C, CO combustion was more temperature dependent than that of H₂, while H₂ combustion was activated by repeated exposure to H₂ gas during the periodic gas test. Selective CO sensing of the micro-TGS against H₂ was attempted using a double catalyst structure with 0.3-30 wt% Pt/α-Al₂O₃ as a counterpart combustion catalyst. The sensor output of the micro-TGS decreased with increasing Pt content in the Pt/α-Al₂O₃ catalyst, by cancelling out the combustion heat from the AuPtPd/SnO₂ catalyst. In addition, the AuPtPd/SnO₂ and 0.3 wt% Pt/α-Al₂O₃ double catalyst sensor showed good and selective CO detection. We therefore demonstrated that our micro-TGS with double catalyst structure is useful for controlling the gas selectivity of CO against H₂.

  18. Carbon paper supported Pt/Au catalysts prepared via Cu underpotential deposition-redox replacement and investigation of their electrocatalytic activity for methanol oxidation and oxygen reduction reactions

    Energy Technology Data Exchange (ETDEWEB)

    Khosravi, Mohsen; Amini, Mohammad K. [Chemistry Department, University of Isfahan, Isfahan 81744-73441 (Iran)

    2010-10-15

    Through a simple and rapid method, carbon papers (CPs) were coated with Au and the resulting Au/CP substrates were used for the preparation of Pt/Au/CP by Cu underpotential deposition (Cu UPD) and redox replacement technique. A series of Pt{sub n}/Au/CP catalysts (where n = number of UPD-redox replacement cycles) were synthesized and their electrochemical properties for methanol oxidation reaction (MOR), and oxygen reduction reaction (ORR) were investigated by electrochemical measurements. The Pt{sub n}/Au/CP electrodes show higher electrocatalytic activity and enhanced poison tolerance for the MOR as compared to a commercial Pt/C on CP (Pt/C/CP). The highest mass specific activity and Pt utilization efficiency for MOR was observed on Pt{sub 1}/Au/CP with a thickness close to a monatomic Pt layer. Chronoamperometric tests in methanol solution revealed that Pt{sub n}/Au/CPs have much higher CO tolerance compared to Pt/C/CP. Among the Pt{sub n}/Au/CPs, CO tolerance decreases with increasing the amount of deposited Pt, indicating that the exposed Au atoms in close proximity to Pt plays a positive role against CO poisoning. Compared with the Pt/C/CP, all the Pt{sub n}/Au/CP electrodes show more positive onset potentials and lower overpotentials for ORR. For instance, the onset potential of ORR is 150 mV more positive and the overpotential is {proportional_to}140 mV lower on Pt{sub 4}/Au/CP with respect to Pt/C/CP. (author)

  19. [Nasogastric tubes: a lot of bother].

    Science.gov (United States)

    Tagliabue, Fabio; D'Angelo, Carlo; Zuccon, William; Giorgetta, Casimiro; Balduzzi, Valerio; Gambarini, Fabrizio; Bonandrini, Luigi

    2008-01-01

    The insertion of the nasogastric tube is one of the procedure that produces the most discomfort for the patients and practitioners. The AA, with the make use of their clinical experience and the data of the literature, report some personal reflections about the management of the nasogastric tube. The AA also analyse some variables (choice of the tube, approach to the patient, insertion of the tube, examination of the position, fixation and removal) that can influence on discomfort of the patient. The choice of the most right SNG is an important moment for the correct insertion; an effect we need to adjust the material and diameter of the tube to the prearranged use. The common practice demonstrates that the collaboration with the patient, obtained by "direct" and "indirect" strategies, gives more possibilities to immediately success of this procedure. The literature explains that it is possible to decrease the discomfort with topical anesthesia; still there are some points of view to clarify. From analyse of the different methods to check the position of SNG, the pH test of the aspirating fluid is the best solution. Once examination of right placement, we need to fix in different points (at least two). From personal experience the removal of SNG is better tolerate that the insertion because the patient is more conscious to be on the mend. The principal recommendation is to abstain from insertion of SNG if it is not closely necessary!

  20. Rupture pressure of wear degraded alloy 600 steam generator tubings

    Science.gov (United States)

    Hwang, Seong Sik; Namgung, Chan; Jung, Man Kyo; Kim, Hong Pyo; Kim, Joung Soo

    2008-02-01

    Fretting/wear degradation at the tube support in the U-bend region of a steam generator (SG) of a pressurized water reactor (PWR) has been reported. Simulated fretted flaws were machined on SG tubes of 195 mm in length. A pressure test was carried out with the tubes at room temperature by using a high pressure test facility which consisted of a water pressurizing pump, a test specimen section and a control unit. Water leak rates just after a ligament rupture or a burst were measured. Tubes degraded by up to 70% of the tube wall thickness (TW) showed a high safety margin in terms of the burst pressure during normal operating conditions. Tubes degraded by up to 50% of the TW did not show burst. Burst pressure depended on the defect depths rather than on the wrap angles. The tube with a wrap angle of 0° showed a fish mouth fracture, whereas the tube with a 45° wrap angle showed a three way fracture.