WorldWideScience

Sample records for pseudorandom pulse sequences

  1. Generation and application of pseudorandom binary sequences using virtual instrumentation

    OpenAIRE

    Miljković, Goran S.; Stojković, Ivana S.; Denić, Dragan B.

    2011-01-01

    A very dynamical development of virtual instrumentation in recent years has caused a very good acceptance of this concept and its use in many applications. This concept, as one flexible and cost-effective solution for test and measurement, is used in this paper for implementation and application of maximum length pseudorandom binary sequences generator. Because of their properties, the pseudorandom binary sequences are often used in development and improvement of modern pseudorandom position ...

  2. Cryptographic pseudo-random sequences from the chaotic Hénon ...

    Indian Academy of Sciences (India)

    Pseudo-random number sequences are useful in many applications including Monte-Carlo simulation, spread spectrum ... a pseudo-random binary sequence from the two-dimensional chaotic Hénon map is explored. ... is the Hénon map, a two-dimensional discrete-time nonlinear dynamical system represented by the state ...

  3. Optimal pseudorandom sequence selection for online c-VEP based BCI control applications

    DEFF Research Database (Denmark)

    Isaksen, Jonas L.; Mohebbi, Ali; Puthusserypady, Sadasivan

    2017-01-01

    Background: In a c-VEP BCI setting, test subjects can have highly varying performances when different pseudorandom sequences are applied as stimulus, and ideally, multiple codes should be supported. On the other hand, repeating the experiment with many different pseudorandom sequences is a labori......Background: In a c-VEP BCI setting, test subjects can have highly varying performances when different pseudorandom sequences are applied as stimulus, and ideally, multiple codes should be supported. On the other hand, repeating the experiment with many different pseudorandom sequences...... predictor. Conclusions: The simple and fast method presented in this study as the Accuracy Score, allows c-VEP based BCI systems to support multiple pseudorandom sequences without increase in trial length. This allows for more personalized BCI systems with better performance to be tested without increased...

  4. Method for Generating Pseudorandom Sequences with the Assured Period Based on R-blocks

    Directory of Open Access Journals (Sweden)

    M. A. Ivanov

    2011-03-01

    Full Text Available The article describes the characteristics of a new class of fast-acting pseudorandom number generators, based on the use of stochastic adders or R-blocks. A new method for generating pseudorandom sequences with the assured length of period is offered.

  5. Quasi-Coherent Noise Jamming to LFM Radar Based on Pseudo-random Sequence Phase-modulation

    Directory of Open Access Journals (Sweden)

    N. Tai

    2015-12-01

    Full Text Available A novel quasi-coherent noise jamming method is proposed against linear frequency modulation (LFM signal and pulse compression radar. Based on the structure of digital radio frequency memory (DRFM, the jamming signal is acquired by the pseudo-random sequence phase-modulation of sampled radar signal. The characteristic of jamming signal in time domain and frequency domain is analyzed in detail. Results of ambiguity function indicate that the blanket jamming effect along the range direction will be formed when jamming signal passes through the matched filter. By flexible controlling the parameters of interrupted-sampling pulse and pseudo-random sequence, different covering distances and jamming effects will be achieved. When the jamming power is equivalent, this jamming obtains higher process gain compared with non-coherent jamming. The jamming signal enhances the detection threshold and the real target avoids being detected. Simulation results and circuit engineering implementation validate that the jamming signal covers real target effectively.

  6. Design of pseudorandom binary sequence generator using lithium-niobate-based Mach-Zehnder interferometers

    Science.gov (United States)

    Choudhary, Kuldeep; Kumar, Santosh

    2017-05-01

    The application of electro-optic effect in lithium-niobate-based Mach-Zehnder interferometer to design a 3-bit optical pseudorandom binary sequence (PRBS) generator has been proposed, which is characterized by its simplicity of generation and stability. The proposed device is optoelectronic in nature. The PBRS generator is immensely applicable for pattern generation, encryption, and coding applications in optical networks. The study is carried out by simulating the proposed device with beam propagation method.

  7. Design of Long Period Pseudo-Random Sequences from the Addition of m -Sequences over 𝔽 p

    Directory of Open Access Journals (Sweden)

    Ren Jian

    2004-01-01

    Full Text Available Pseudo-random sequence with good correlation property and large linear span is widely used in code division multiple access (CDMA communication systems and cryptology for reliable and secure information transmission. In this paper, sequences with long period, large complexity, balance statistics, and low cross-correlation property are constructed from the addition of m -sequences with pairwise-prime linear spans (AMPLS. Using m -sequences as building blocks, the proposed method proved to be an efficient and flexible approach to construct long period pseudo-random sequences with desirable properties from short period sequences. Applying the proposed method to 𝔽 2 , a signal set ( ( 2 n − 1 ( 2 m − 1 , ( 2 n + 1 ( 2 m + 1 , ( 2 ( n + 1 / 2 + 1 ( 2 ( m + 1 / 2 + 1 is constructed.

  8. Cardiorespiratory Kinetics Determined by Pseudo-Random Binary Sequences - Comparisons between Walking and Cycling.

    Science.gov (United States)

    Koschate, J; Drescher, U; Thieschäfer, L; Heine, O; Baum, K; Hoffmann, U

    2016-12-01

    This study aims to compare cardiorespiratory kinetics as a response to a standardised work rate protocol with pseudo-random binary sequences between cycling and walking in young healthy subjects. Muscular and pulmonary oxygen uptake (V̇O2) kinetics as well as heart rate kinetics were expected to be similar for walking and cycling. Cardiac data and V̇O2 of 23 healthy young subjects were measured in response to pseudo-random binary sequences. Kinetics were assessed applying time series analysis. Higher maxima of cross-correlation functions between work rate and the respective parameter indicate faster kinetics responses. Muscular V̇O2 kinetics were estimated from heart rate and pulmonary V̇O2 using a circulatory model. Muscular (walking vs. cycling [mean±SD in arbitrary units]: 0.40±0.08 vs. 0.41±0.08) and pulmonary V̇O2 kinetics (0.35±0.06 vs. 0.35±0.06) were not different, although the time courses of the cross-correlation functions of pulmonary V̇O2 showed unexpected biphasic responses. Heart rate kinetics (0.50±0.14 vs. 0.40±0.14; P=0.017) was faster for walking. Regarding the biphasic cross-correlation functions of pulmonary V̇O2 during walking, the assessment of muscular V̇O2 kinetics via pseudo-random binary sequences requires a circulatory model to account for cardio-dynamic distortions. Faster heart rate kinetics for walking should be considered by comparing results from cycle and treadmill ergometry. © Georg Thieme Verlag KG Stuttgart · New York.

  9. A comparative study of pseudorandom sequences used in a c-VEP based BCI for online wheelchair control

    DEFF Research Database (Denmark)

    Isaksen, Jonas L.; Mohebbi, Ali; Puthusserypady, Sadasivan

    2016-01-01

    In this study, a c-VEP based BCI system was developed to run on three distinctive pseudorandom sequences, namely the m-code, the Gold-code, and the Barker-code. The Visual Evoked Potentials (VEPs) were provoked using these codes. In the online session, subjects controlled a LEGO® Mindstorms® robot...

  10. Pseudorandom Bit Sequence Generator for Stream Cipher Based on Elliptic Curves

    Directory of Open Access Journals (Sweden)

    Jilna Payingat

    2015-01-01

    Full Text Available This paper proposes a pseudorandom sequence generator for stream ciphers based on elliptic curves (EC. A detailed analysis of various EC based random number generators available in the literature is done and a new method is proposed such that it addresses the drawbacks of these schemes. Statistical analysis of the proposed method is carried out using the NIST (National Institute of Standards and Technology test suite and it is seen that the sequence exhibits good randomness properties. The linear complexity analysis shows that the system has a linear complexity equal to the period of the sequence which is highly desirable. The statistical complexity and security against known plain text attack are also analysed. A comparison of the proposed method with other EC based schemes is done in terms of throughput, periodicity, and security, and the proposed method outperforms the methods in the literature. For resource constrained applications where a highly secure key exchange is essential, the proposed method provides a good option for encryption by time sharing the point multiplication unit for EC based key exchange. The algorithm and architecture for implementation are developed in such a way that the hardware consumed in addition to point multiplication unit is much less.

  11. SNMR pulse sequence phase cycling

    Science.gov (United States)

    Walsh, David O; Grunewald, Elliot D

    2013-11-12

    Technologies applicable to SNMR pulse sequence phase cycling are disclosed, including SNMR acquisition apparatus and methods, SNMR processing apparatus and methods, and combinations thereof. SNMR acquisition may include transmitting two or more SNMR pulse sequences and applying a phase shift to a pulse in at least one of the pulse sequences, according to any of a variety cycling techniques. SNMR processing may include combining SNMR from a plurality of pulse sequences comprising pulses of different phases, so that desired signals are preserved and indesired signals are canceled.

  12. Optical 10-20 and 20-40 Gbits/s pseudorandom bit sequence data multiplexing utilizing conversion-dispersion-based tunable optical delays.

    Science.gov (United States)

    Wu, Xiaoxia; Christen, Louis; Yilmaz, Omer F; Nuccio, Scott R; Willner, Alan E

    2008-07-01

    We experimentally demonstrate all-optical 2(7)-1 pseudorandom bit sequence data multiplexing using wavelength conversion, interchannel chromatic dispersion, and intrachannel dispersion compensation. Bit-rate tuning capability is demonstrated with 10-20 and 20-40 Gbits/s multiplexing, achieving a bit-error rate <10(-9) for both rates.

  13. Bit-rate-variable and order-switchable optical multiplexing of high-speed pseudorandom bit sequence using optical delays.

    Science.gov (United States)

    Wu, Xiaoxia; Wang, Jian; Yilmaz, Omer F; Nuccio, Scott R; Bogoni, Antonella; Willner, Alan E

    2010-09-15

    We experimentally demonstrate high-speed optical pseudorandom bit sequence (PRBS) multiplexing with coarse and fine bit-rate tuning capability and a switchable order using optical delays. Data multiplexing of 80 Gbit/s and 160 Gbit/s is shown, each with a tunable rate using a conversion/dispersion-based continuously tunable optical delay and tunable PRBS order with large switchable fiber delays. A 7% bit-rate tunability, i.e., 80-85.6 Gbit/s and 160-171.2 Gbit/s, is shown for both 2(7)-1 and 2(15)-1 PRBS. The rf spectra before and after multiplexing are measured in each case and show a suppression ratio of >30 dB, exhibiting the expected PRBS spectral characteristics.

  14. Features of the propagation of pseudorandom pulse signals from the shelf to deep water in the presence of gyre formation on the acoustic track

    Science.gov (United States)

    Akulichev, V. A.; Burenin, A. V.; Ladychenko, S. Yu.; Lobanov, V. B.; Morgunov, Yu. N.

    2017-08-01

    The paper discusses the results of an experiment conducted in the Sea of Japan in March 2016 on an acoustic track 194 km long in winter hydrological conditions. The most complex case of propagation of pseudorandom pulse signals from the shelf to deep water in the presence of gyre formation on the acoustic track. An analysis of the experimentally obtained pulse characteristics show that at all points, a maximum, in terms of amplitude, first arrival of acoustic energy is recorded. This is evidence that at a given depth horizon, pulses that have passed the shortest distance through a near-surface sound channel at small angles close to zero are received first. The calculation method of mean sound velocity on the track, based on the satellite data of surface temperature monitoring, is proposed. We expect that the results obtained with this method can be successfully used for the purposes of acoustic range finding and navigation.

  15. Analysis of heart rate and oxygen uptake kinetics studied by two different pseudo-random binary sequence work rate amplitudes.

    Science.gov (United States)

    Drescher, U; Koschate, J; Schiffer, T; Schneider, S; Hoffmann, U

    2017-06-01

    The aim of the study was to compare the kinetics responses of heart rate (HR), pulmonary (V˙O2pulm) and predicted muscular (V˙O2musc) oxygen uptake between two different pseudo-random binary sequence (PRBS) work rate (WR) amplitudes both below anaerobic threshold. Eight healthy individuals performed two PRBS WR protocols implying changes between 30W and 80W and between 30W and 110W. HR and V˙O2pulm were measured beat-to-beat and breath-by-breath, respectively. V˙O2musc was estimated applying the approach of Hoffmann et al. (Eur J Appl Physiol 113: 1745-1754, 2013) considering a circulatory model for venous return and cross-correlation functions (CCF) for the kinetics analysis. HR and V˙O2musc kinetics seem to be independent of WR intensity (p>0.05). V˙O2pulm kinetics show prominent differences in the lag of the CCF maximum (39±9s; 31±4s; pkinetics remain unchanged. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Cryptographic pseudo-random sequences from the chaotic Hénon ...

    Indian Academy of Sciences (India)

    dimensional discrete-time Hénon map is proposed. Properties of the proposed sequences pertaining to linear complexity, linear complexity profile, correlation and auto-correlation are investigated. All these properties of the sequences suggest a ...

  17. Pseudorandomness in Central Force Optimization

    OpenAIRE

    Formato, Richard A.

    2010-01-01

    Central Force Optimization is a deterministic metaheuristic for an evolutionary algorithm that searches a decision space by flying probes whose trajectories are computed using a gravitational metaphor. CFO benefits substantially from the inclusion of a pseudorandom component (a numerical sequence that is precisely known by specification or calculation but otherwise arbitrary). The essential requirement is that the sequence is uncorrelated with the decision space topology, so that its effect i...

  18. Design of Long Period Pseudo-Random Sequences from the Addition of m -Sequences over 𝔽 p

    OpenAIRE

    Ren Jian

    2004-01-01

    Pseudo-random sequence with good correlation property and large linear span is widely used in code division multiple access (CDMA) communication systems and cryptology for reliable and secure information transmission. In this paper, sequences with long period, large complexity, balance statistics, and low cross-correlation property are constructed from the addition of m -sequences with pairwise-prime linear spans (AMPLS). Using m -sequences as building blocks, the proposed method proved to...

  19. Use of the Frank sequence in pulsed EPR

    DEFF Research Database (Denmark)

    Tseitlin, Mark; Quine, Richard W.; Eaton, Sandra S.

    2011-01-01

    The Frank polyphase sequence has been applied to pulsed EPR of triarylmethyl radicals at 256MHz (9.1mT magnetic field), using 256 phase pulses. In EPR, as in NMR, use of a Frank sequence of phase steps permits pulsed FID signal acquisition with very low power microwave/RF pulses (ca. 1.5m......W in the application reported here) relative to standard pulsed EPR. A 0.2mM aqueous solution of a triarylmethyl radical was studied using a 16mm diameter cross-loop resonator to isolate the EPR signal detection system from the incident pulses. Keyword: Correlation spectroscopy,Multi-pulse EPR,Low power pulses...

  20. Cryptography, statistics and pseudo-randomness (Part 1)

    NARCIS (Netherlands)

    Brands, S.; Gill, R.D.

    1995-01-01

    In the classical approach to pseudo-random number generators, a generator is considered to perform well if its output sequences pass a battery of statistical tests that has become standard. In recent years, it has turned out that this approach is not satisfactory. Many generators have turned out to

  1. Pseudorandom number generation using chaotic true orbits of the Bernoulli map

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Asaki, E-mail: saito@fun.ac.jp [Future University Hakodate, 116-2 Kamedanakano-cho, Hakodate, Hokkaido 041-8655 (Japan); Yamaguchi, Akihiro [Fukuoka Institute of Technology, 3-30-1 Wajiro-higashi, Higashi-ku, Fukuoka 811-0295 (Japan)

    2016-06-15

    We devise a pseudorandom number generator that exactly computes chaotic true orbits of the Bernoulli map on quadratic algebraic integers. Moreover, we describe a way to select the initial points (seeds) for generating multiple pseudorandom binary sequences. This selection method distributes the initial points almost uniformly (equidistantly) in the unit interval, and latter parts of the generated sequences are guaranteed not to coincide. We also demonstrate through statistical testing that the generated sequences possess good randomness properties.

  2. TOPPE: A framework for rapid prototyping of MR pulse sequences.

    Science.gov (United States)

    Nielsen, Jon-Fredrik; Noll, Douglas C

    2017-11-02

    To introduce a framework for rapid prototyping of MR pulse sequences. We propose a simple file format, called "TOPPE", for specifying all details of an MR imaging experiment, such as gradient and radiofrequency waveforms and the complete scan loop. In addition, we provide a TOPPE file "interpreter" for GE scanners, which is a binary executable that loads TOPPE files and executes the sequence on the scanner. We also provide MATLAB scripts for reading and writing TOPPE files and previewing the sequence prior to hardware execution. With this setup, the task of the pulse sequence programmer is reduced to creating TOPPE files, eliminating the need for hardware-specific programming. No sequence-specific compilation is necessary; the interpreter only needs to be compiled once (for every scanner software upgrade). We demonstrate TOPPE in three different applications: k-space mapping, non-Cartesian PRESTO whole-brain dynamic imaging, and myelin mapping in the brain using inhomogeneous magnetization transfer. We successfully implemented and executed the three example sequences. By simply changing the various TOPPE sequence files, a single binary executable (interpreter) was used to execute several different sequences. The TOPPE file format is a complete specification of an MR imaging experiment, based on arbitrary sequences of a (typically small) number of unique modules. Along with the GE interpreter, TOPPE comprises a modular and flexible platform for rapid prototyping of new pulse sequences. Magn Reson Med, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  3. Autocorrelation peaks in congruential pseudorandom number generators

    Science.gov (United States)

    Neuman, F.; Merrick, R. B.

    1976-01-01

    The complete correlation structure of several congruential pseudorandom number generators (PRNG) of the same type and small cycle length was studied to deal with the problem of congruential PRNG almost repeating themselves at intervals smaller than their cycle lengths, during simulation of bandpass filtered normal random noise. Maximum period multiplicative and mixed congruential generators were studied, with inferences drawn from examination of several tractable members of a class of random number generators, and moduli from 2 to the 5th power to 2 to the 9th power. High correlation is shown to exist in mixed and multiplicative congruential random number generators and prime moduli Lehmer generators for shifts a fraction of their cycle length. The random noise sequences in question are required when simulating electrical noise, air turbulence, or time variation of wind parameters.

  4. Feedback optimization of pulse width in the SORC sequence.

    Science.gov (United States)

    Schiano, J L; Routhier, T; Blauch, A J; Ginsberg, M D

    1999-09-01

    A method for increasing the signal-to-noise ratio (SNR) of nuclear quadrupole resonance (NQR) measurements by automatically adjusting a pulse parameter in real-time is presented. This approach is useful in situations where the optimal pulse parameters cannot be chosen beforehand due to lack of knowledge regarding the system. For example, NQR provides a means for detecting explosives by revealing the presence of (14)N. In this particular application, the distance between the search coil and the explosive, as well as the temperature of the explosive, is unknown. As a result, a fixed set of pulse parameters will not yield the largest SNR for all possible search applications. This paper describes a feedback algorithm that uses measurements of the NQR signal to automatically adjust the pulse width in the strong off-resonant comb sequence to maximize the SNR of the NQR measurement. Experimental results obtained using a sample of sodium nitrite are presented. Copyright 1999 Academic Press.

  5. Pulse Sequence Shaper For Radiospectroscopy And Relaxation Methods In NQR

    Directory of Open Access Journals (Sweden)

    Bobalo Yuriy

    2015-09-01

    Full Text Available A pulse sequence shaper for the pursuance of the research using a wide spectrum of radiospectroscopy and relaxation methods in NQR is proposed. The distinctive feature of this product is its implementation with the application of a multi-functional programmable frequency synthesizer suitable for high-speed amplitude and phase manipulations.

  6. High Throughput Pseudorandom Number Generator Based on Variable Argument Unified Hyperchaos

    Directory of Open Access Journals (Sweden)

    Kaiyu Wang

    2014-01-01

    Full Text Available This paper presents a new multioutput and high throughput pseudorandom number generator. The scheme is to make the homogenized Logistic chaotic sequence as unified hyperchaotic system parameter. So the unified hyperchaos can transfer in different chaotic systems and the output can be more complex with the changing of homogenized Logistic chaotic output. Through processing the unified hyperchaotic 4-way outputs, the output will be extended to 26 channels. In addition, the generated pseudorandom sequences have all passed NIST SP800-22 standard test and DIEHARD test. The system is designed in Verilog HDL and experimentally verified on a Xilinx Spartan 6 FPGA for a maximum throughput of 16.91 Gbits/s for the native chaotic output and 13.49 Gbits/s for the resulting pseudorandom number generators.

  7. Nonquadratic Variation of the Blum Blum Shub Pseudorandom Number Generator

    Science.gov (United States)

    2016-09-01

    the use of random numbers. For this rea- son, cryptographers design pseudorandom number generators (PRNG) as a method of generating random numbers...fails the block frequency test, as it is clearly not random . 3.3.3 Runs Test A run is defined as a series of either 1’s or 0’s in a row. The purpose of...that would be expected of a random sequence. The NIST standard uses three common block sizes for this test, M = 8, 128, and 10, 000. The test divides

  8. Synchronized pseudorandom systems and their application to speech communication.

    Science.gov (United States)

    Zhang, Yu; Tao, Chao; Du, Gonghuan; Jiang, Jack J

    2005-01-01

    An approach to the synchronization of pseudorandom systems is proposed and applied to secure speech communication. The encoding signal produced by the pseudorandom synchronization scheme passes the random test, and shows much more complex dynamics, better random properties, and greater sensitivity to parameter mismatches than that produced by the active-passive decomposition scheme. Also, two coupled pseudorandom systems can be exactly synchronized despite their different initial states or seeds. Pseudorandom encoding and synchronization may yield great security in communication.

  9. Pseudorandomness analysis of the (extended) Lai–Massey scheme

    NARCIS (Netherlands)

    Luo, Yiyuan; Desmedt, Y.; Lai, Xuejia; Gong, Zheng

    2010-01-01

    In this paper we find that the two-round (extended) Lai–Massey scheme is not pseudorandom and three-round (extended) Lai–Massey scheme is not strong pseudorandom. Combined with previous work, we prove that three rounds are necessary and sufficient for the pseudorandomness and four rounds are

  10. Pseudo-random number generator based on asymptotic deterministic randomness

    Energy Technology Data Exchange (ETDEWEB)

    Wang Kai [Department of Radio Engineering, Southeast University, Nanjing (China)], E-mail: kaiwang@seu.edu.cn; Pei Wenjiang; Xia Haishan [Department of Radio Engineering, Southeast University, Nanjing (China); Cheung Yiuming [Department of Computer Science, Hong Kong Baptist University, Hong Kong (China)

    2008-06-09

    A novel approach to generate the pseudorandom-bit sequence from the asymptotic deterministic randomness system is proposed in this Letter. We study the characteristic of multi-value correspondence of the asymptotic deterministic randomness constructed by the piecewise linear map and the noninvertible nonlinearity transform, and then give the discretized systems in the finite digitized state space. The statistic characteristics of the asymptotic deterministic randomness are investigated numerically, such as stationary probability density function and random-like behavior. Furthermore, we analyze the dynamics of the symbolic sequence. Both theoretical and experimental results show that the symbolic sequence of the asymptotic deterministic randomness possesses very good cryptographic properties, which improve the security of chaos based PRBGs and increase the resistance against entropy attacks and symbolic dynamics attacks.

  11. MR pulse sequences for selective relaxation time measurements: a phantom study

    DEFF Research Database (Denmark)

    Thomsen, C; Jensen, K E; Jensen, M

    1990-01-01

    The accuracy of relaxation time measurements of spectroscopic inversion recovery and CPMG multi-echo pulse sequences together with ISIS and stimulated echo-pulse methods have been tested on a reference phantom (test object no. 5, of the EEC Concerted Research Project). For the measurements...... a Siemens Magnetom wholebody magnetic resonance scanner operating at 1.5 Tesla was used. For comparison six imaging pulse sequences for relaxation time measurements were tested on the same phantom. The spectroscopic pulse sequences all had an accuracy better than 10% of the reference values....

  12. A dispersion-balanced Discrete Fourier Transform of repetitive pulse sequences using temporal Talbot effect

    Science.gov (United States)

    Fernández-Pousa, Carlos R.

    2017-11-01

    We propose a processor based on the concatenation of two fractional temporal Talbot dispersive lines with balanced dispersion to perform the DFT of a repetitive electrical sequence, for its use as a controlled source of optical pulse sequences. The electrical sequence is used to impart the amplitude and phase of a coherent train of optical pulses by use of a modulator placed between the two Talbot lines. The proposal has been built on a representation of the action of fractional Talbot effect on repetitive pulse sequences and a comparison with related results and proposals. It is shown that the proposed system is reconfigurable within a few repetition periods, has the same processing rate as the input optical pulse train, and requires the same technical complexity in terms of dispersion and pulse width as the standard, passive pulse-repetition rate multipliers based on fractional Talbot effect.

  13. Trifork, a New Pseudorandom Number Generator Based on Lagged Fibonacci Maps

    OpenAIRE

    Orue, A.B.; Montoya, F.; Hernández Encinas, Luis

    2010-01-01

    A new family of cryptographically secure pseudorandom number generators, is described. It is based on the combination of the sequences generated by three coupled Lagged Fibonacci generators, mutually perturbed. The mutual perturbation method consists of the bitwise XOR cross-addition of the output of each generator with the right-shifted output of the nearby generator. The proposed generator has better entropy and much longer repetition period than the conventional Lagged Fibonacci Generator....

  14. Calibration of Correlation Radiometers Using Pseudo-Random Noise Signals

    Directory of Open Access Journals (Sweden)

    Sebastián Pantoja

    2009-08-01

    Full Text Available The calibration of correlation radiometers, and particularly aperture synthesis interferometric radiometers, is a critical issue to ensure their performance. Current calibration techniques are based on the measurement of the cross-correlation of receivers’ outputs when injecting noise from a common noise source requiring a very stable distribution network. For large interferometric radiometers this centralized noise injection approach is very complex from the point of view of mass, volume and phase/amplitude equalization. Distributed noise injection techniques have been proposed as a feasible alternative, but are unable to correct for the so-called “baseline errors” associated with the particular pair of receivers forming the baseline. In this work it is proposed the use of centralized Pseudo-Random Noise (PRN signals to calibrate correlation radiometers. PRNs are sequences of symbols with a long repetition period that have a flat spectrum over a bandwidth which is determined by the symbol rate. Since their spectrum resembles that of thermal noise, they can be used to calibrate correlation radiometers. At the same time, since these sequences are deterministic, new calibration schemes can be envisaged, such as the correlation of each receiver’s output with a baseband local replica of the PRN sequence, as well as new distribution schemes of calibration signals. This work analyzes the general requirements and performance of using PRN sequences for the calibration of microwave correlation radiometers, and particularizes the study to a potential implementation in a large aperture synthesis radiometer using an optical distribution network.

  15. Calibration of correlation radiometers using pseudo-random noise signals.

    Science.gov (United States)

    Pérez, Isaac Ramos; Bosch-Lluis, Xavi; Camps, Adriano; Alvarez, Nereida Rodriguez; Hernandez, Juan Fernando Marchán; Domènech, Enric Valencia; Vernich, Carlos; de la Rosa, Sonia; Pantoja, Sebastián

    2009-01-01

    The calibration of correlation radiometers, and particularly aperture synthesis interferometric radiometers, is a critical issue to ensure their performance. Current calibration techniques are based on the measurement of the cross-correlation of receivers' outputs when injecting noise from a common noise source requiring a very stable distribution network. For large interferometric radiometers this centralized noise injection approach is very complex from the point of view of mass, volume and phase/amplitude equalization. Distributed noise injection techniques have been proposed as a feasible alternative, but are unable to correct for the so-called "baseline errors" associated with the particular pair of receivers forming the baseline. In this work it is proposed the use of centralized Pseudo-Random Noise (PRN) signals to calibrate correlation radiometers. PRNs are sequences of symbols with a long repetition period that have a flat spectrum over a bandwidth which is determined by the symbol rate. Since their spectrum resembles that of thermal noise, they can be used to calibrate correlation radiometers. At the same time, since these sequences are deterministic, new calibration schemes can be envisaged, such as the correlation of each receiver's output with a baseband local replica of the PRN sequence, as well as new distribution schemes of calibration signals. This work analyzes the general requirements and performance of using PRN sequences for the calibration of microwave correlation radiometers, and particularizes the study to a potential implementation in a large aperture synthesis radiometer using an optical distribution network.

  16. Hypercapnic normalization of BOLD fMRI: comparison across field strengths and pulse sequences

    DEFF Research Database (Denmark)

    Cohen, Eric R.; Rostrup, Egill; Sidaros, Karam

    2004-01-01

    size, as well as experimental, such as pulse sequence and static magnetic field strength (B(0)). Thus, it is difficult to compare task-induced fMRI signals across subjects, field strengths, and pulse sequences. This problem can be overcome by normalizing the neural activity-induced BOLD fMRI response...... to be more accurately localized and quantified based on changes in venous blood oxygenation alone. The normalized BOLD signal induced by the motor task was consistent across different magnetic fields and pulse sequences, and corresponded well with cerebral blood flow measurements. Our data suggest...... that the hypercapnic normalization approach can improve the spatial specificity and interpretation of BOLD signals, allowing comparison of BOLD signals across subjects, field strengths, and pulse sequences. A theoretical framework for this method is provided...

  17. Research of the method of pseudo-random number generation based on asynchronous cellular automata with several active cells

    Directory of Open Access Journals (Sweden)

    Bilan Stepan

    2017-01-01

    Full Text Available To date, there are many tasks that are aimed at studying the dynamic changes in physical processes. These tasks do not give advance known result. The solution of such problems is based on the construction of a dynamic model of the object. Successful structural and functional implementation of the object model can give a positive result in time. This approach uses the task of constructing artificial biological objects. To solve such problems, pseudo-random number generators are used, which also find wide application for information protection tasks. Such generators should have good statistical properties and give a long repetition period of the generated pseudo-random bit sequence. This work is aimed at improving these characteristics. The paper considers the method of forming pseudo-random sequences of numbers on the basis of aperiodic cellular automata with two active cells. A pseudo-random number generator is proposed that generates three bit sequences. The first two bit sequences are formed by the corresponding two active cells in the cellular automaton. The third bit sequence is the result of executing the XOR function over the bits of the first two sequences and it has better characteristics compared to them. The use of cellular automata with two active cells allowed to improve the statistical properties of the formed bit sequence, as well as its repetition period. This is proved by using graphical tests for generators built based on cellular automata using the neighborhoods of von Neumann and Moore. The tests showed high efficiency of the generator based on an asynchronous cellular automaton with the neighborhood of Moore. The proposed pseudo-random number generators have good statistical properties, which makes it possible to use them in information security systems, as well as for simulation tasks of various dynamic processes.

  18. Estimate of pulse-sequence data acquisition system for multi-dimensional measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kitamura, Yasunori; Sakae, Takeji; Nohtomi, Akihiro; Matoba, Masaru [Kyushu Univ., Fukuoka (Japan). Faculty of Engineering; Matsumoto, Yuzuru

    1996-07-01

    A pulse-sequence data acquisition system has been newly designed and estimated for the measurement of one- or multi-dimensional pulse train coming from radiation detectors. In this system, in order to realize the pulse-sequence data acquisition, the arrival time of each pulse is recorded to a memory of a personal computer (PC). For the multi-dimensional data acquisition with several input channels, each arrival-time data is tagged with a `flag` which indicates the input channel of arriving pulse. Counting losses due to the existence of processing time of the PC are expected to be reduced by using a First-In-First-Out (FIFO) memory unit. In order to verify this system, a computer simulation was performed, Various sets of random pulse trains with different mean pulse rate (1-600 kcps) were generated by using Monte Carlo simulation technique. Those pulse trains were dealt with another code which simulates the newly-designed data acquisition system including a FIFO memory unit; the memory size was assumed to be 0-100 words. And the recorded pulse trains on the PC with the various FIFO memory sizes have been observed. From the result of the simulation, it appears that the system with 3 words FIFO memory unit works successfully up to the pulse rate of 10 kcps without any severe counting losses. (author)

  19. Comparison of ompP5 sequence-based typing and pulsed-filed gel ...

    African Journals Online (AJOL)

    In this study, comparison of the outer membrane protein P5 gene (ompP5) sequence-based typing with pulsed-field gel electrophoresis (PFGE) for the genotyping of Haemophilus parasuis, the 15 serovar reference strains and 43 isolates were investigated. When comparing the two methods, 31 ompP5 sequence types ...

  20. Current density imaging sequence for monitoring current distribution during delivery of electric pulses in irreversible electroporation.

    Science.gov (United States)

    Serša, Igor; Kranjc, Matej; Miklavčič, Damijan

    2015-01-01

    Electroporation is gaining its importance in everyday clinical practice of cancer treatment. For its success it is extremely important that coverage of the target tissue, i.e. treated tumor, with electric field is within the specified range. Therefore, an efficient tool for the electric field monitoring in the tumor during delivery of electroporation pulses is needed. The electric field can be reconstructed by the magnetic resonance electric impedance tomography method from current density distribution data. In this study, the use of current density imaging with MRI for monitoring current density distribution during delivery of irreversible electroporation pulses was demonstrated. Using a modified single-shot RARE sequence, where four 3000 V and 100 μs long pulses were included at the start, current distribution between a pair of electrodes inserted in a liver tissue sample was imaged. Two repetitions of the sequence with phases of refocusing radiofrequency pulses 90° apart were needed to acquire one current density image. For each sample in total 45 current density images were acquired to follow a standard protocol for irreversible electroporation where 90 electric pulses are delivered at 1 Hz. Acquired current density images showed that the current density in the middle of the sample increased from first to last electric pulses by 60%, i.e. from 8 kA/m2 to 13 kA/m2 and that direction of the current path did not change with repeated electric pulses significantly. The presented single-shot RARE-based current density imaging sequence was used successfully to image current distribution during delivery of short high-voltage electric pulses. The method has a potential to enable monitoring of tumor coverage by electric field during irreversible electroporation tissue ablation.

  1. Magnetic resonance imaging of the Achilles tendon using ultrashort TE (UTE) pulse sequences

    Energy Technology Data Exchange (ETDEWEB)

    Robson, M.D.; Benjamin, M.; Gishen, P.; Bydder, G.M. E-mail: gbydder@ucsd.edu

    2004-08-01

    AIM: To assess the potential value of imaging the Achilles tendon with ultrashort echo time (UTE) pulse sequences. MATERIALS AND METHODS: Four normal controls and four patients with chronic Achilles tendinopathy were examined in the sagittal and transverse planes. Three of the patients were examined before and after intravenous gadodiamide. RESULTS: The fascicular pattern was clearly demonstrated within the tendon and detail of the three distinct fibrocartilaginous components of an 'enthesis organ' was well seen. T2* measurements showed two short T2* components. Increase in long T2 components with reduction in short T2 components was seen in tendinopathy. Contrast enhancement was much more extensive than with conventional sequences in two cases of tendinopathy but in a third case, there was a region of reduced enhancement. CONCLUSION: UTE pulse sequences provide anatomical detail not apparent with conventional sequences, demonstrate differences in T2* and show patterns of both increased and decreased enhancement in tendinopathy.

  2. Enhanced Refocusing of Fat Signals using Optimized Multi-pulse Echo Sequences

    Science.gov (United States)

    Stokes, Ashley M.; Feng, Yesu; Mitropoulos, Tanya; Warren, Warren S.

    2012-01-01

    Endogenous magnetic resonance contrast based on the localized composition of fat in vivo can provide functional information. We found that the unequal pulse timings of the Uhrig’s Dynamical Decoupling (UDD) multipulse echo sequences significantly alter the signal intensity compared to conventional, equal-spaced Carr-Purcell-Meiboom-Gill (CPMG) sequences. The signal increases and decreases depending on the tissue and sequence parameters, as well as on the interpulse spacings; particularly strong differences were observed in fatty tissues, which have a highly structured morphology and a wide range of chemical shifts and J-couplings. We found that the predominant mechanism for fat refocusing under multipulse echo sequences is the chemical structure, with stimulated echoes playing a pivotal role. As a result, specialized pulse sequences can be designed to optimize refocusing of the fat chemical shifts and J-couplings, where the degree of refocusing can be tailored to specific types of fats. To determine the optimal time delays, we simulated various UDD and CPMG pulse sequence timings, and these results are compared to experimental results obtained on excised and in vivo fatty tissue. Applications to intermolecular multiple-quantum coherence (iMQC) imaging, where the improved echo refocusing translates directly into signal enhancements, are presented as well. PMID:22627966

  3. Controlling the Radiation Parameters of a Resonant Medium Excited by a Sequence of Ultrashort Superluminal Pulses

    Science.gov (United States)

    Arkhipov, R. M.; Arkhipov, M. V.; Belov, P. A.; Babushkin, I.; Tolmachev, Yu. A.

    2016-03-01

    We investigate the possibility of controlling the radiation parameters of a spatially periodic one-dimensional medium consisting of classical harmonic oscillators by means of a sequence of ultrashort pulses that propagate through the medium with a superluminal velocity. We show that, in the spectrum of the transient process, in addition to the radiation at a resonant frequency of oscillators, new frequencies arise that depend on the period of the spatial distribution of the oscillator density, the excitation velocity, and the angle of observation. We have examined in detail the case of excitation of the medium by a periodic sequence of ultrashort pulses that travel with a superluminal velocity. We show that it is possible to excite oscillations of complex shapes and to control the radiation parameters of the resonant medium by changing the relationship between the pulse repetition rate, the medium resonant frequency, and the new frequency.

  4. Fast pulse sequences for dynamically corrected gates in singlet-triplet qubits

    Science.gov (United States)

    Throckmorton, Robert E.; Zhang, Chengxian; Yang, Xu-Chen; Wang, Xin; Barnes, Edwin; Das Sarma, S.

    2017-11-01

    We present a set of experimentally feasible pulse sequences that implement any single-qubit gate on a singlet-triplet spin qubit and demonstrate that these new sequences are up to three times faster than existing sequences in the literature. We show that these sequences can be extended to incorporate built-in dynamical error correction, yielding gates that are robust to both charge and magnetic field noise and up to twice as fast as previous dynamically corrected gate schemes. We present a thorough comparison of the performance of our new sequences with that of several existing ones using randomized benchmarking, considering both quasistatic and 1 /fα noise models. We provide our results both as a function of evolution time and as a function of the number of gates, which respectively yield both an effective coherence time and an estimate of the number of gates that can be performed within this coherence time. We determine which set of pulse sequences gives the best results for a wide range of noise strengths and power spectra. Overall, we find that the traditional, slower sequences perform best when there is no field noise or when the noise contains significant high-frequency components; otherwise, our new, fast sequences exhibit the best performance.

  5. Absorption spectrum of a two-level system subjected to a periodic pulse sequence

    Science.gov (United States)

    Fotso, H. F.; Dobrovitski, V. V.

    2017-06-01

    We investigate how the quantum control of a two-level system (TLS) coupled to photons can modify and tune the TLS's photon absorption spectrum. Tuning and controlling the emission and the absorption are of great interest, e.g., for the development of efficient interfaces between stationary and flying qubits in modern architectures for quantum computation and quantum communication. We consider periodic pulse control, where the TLS is subjected to a periodic sequence of the near-resonant Rabi driving pulses, each pulse implementing a 180∘ rotation. For small interpulse delays, the absorption spectrum features a pronounced peak of stimulated emission at the pulse frequency, similar satellite peaks with smaller spectral weights, and the net absorption peaks on the sides. As long as the detuning between the carrier frequency of the driving and the TLS transition frequency remains moderate, this spectral shape shows little change. Therefore, the pulse control allows shifting the absorption peak to a desired position and locks the overall absorption spectrum to the carrier frequency of the driving pulses. A detailed description of the spectrum and its evolution as a function time, the interpulse spacing, and the detuning is presented.

  6. Pulseq: A rapid and hardware-independent pulse sequence prototyping framework.

    Science.gov (United States)

    Layton, Kelvin J; Kroboth, Stefan; Jia, Feng; Littin, Sebastian; Yu, Huijun; Leupold, Jochen; Nielsen, Jon-Fredrik; Stöcker, Tony; Zaitsev, Maxim

    2017-04-01

    Implementing new magnetic resonance experiments, or sequences, often involves extensive programming on vendor-specific platforms, which can be time consuming and costly. This situation is exacerbated when research sequences need to be implemented on several platforms simultaneously, for example, at different field strengths. This work presents an alternative programming environment that is hardware-independent, open-source, and promotes rapid sequence prototyping. A novel file format is described to efficiently store the hardware events and timing information required for an MR pulse sequence. Platform-dependent interpreter modules convert the file to appropriate instructions to run the sequence on MR hardware. Sequences can be designed in high-level languages, such as MATLAB, or with a graphical interface. Spin physics simulation tools are incorporated into the framework, allowing for comparison between real and virtual experiments. Minimal effort is required to implement relatively advanced sequences using the tools provided. Sequences are executed on three different MR platforms, demonstrating the flexibility of the approach. A high-level, flexible and hardware-independent approach to sequence programming is ideal for the rapid development of new sequences. The framework is currently not suitable for large patient studies or routine scanning although this would be possible with deeper integration into existing workflows. Magn Reson Med 77:1544-1552, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  7. Hypercapnic normalization of BOLD fMRI: comparison across field strengths and pulse sequences

    DEFF Research Database (Denmark)

    Cohen, Eric R.; Rostrup, Egill; Sidaros, Karam

    2004-01-01

    The blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) signal response to neural stimulation is influenced by many factors that are unrelated to the stimulus. These factors are physiological, such as the resting venous cerebral blood volume (CBV(v)) and vessel...... size, as well as experimental, such as pulse sequence and static magnetic field strength (B(0)). Thus, it is difficult to compare task-induced fMRI signals across subjects, field strengths, and pulse sequences. This problem can be overcome by normalizing the neural activity-induced BOLD fMRI response...... by a global hypercapnia-induced BOLD signal. To demonstrate the effectiveness of the BOLD normalization approach, gradient-echo BOLD fMRI at 1.5, 4, and 7 T and spin-echo BOLD fMRI at 4 T were performed in human subjects. For neural stimulation, subjects performed sequential finger movements at 2 Hz, while...

  8. Characterization of an Acoustic Communication Channel with Pseudorandom Binary Sequences

    NARCIS (Netherlands)

    Walree, P.A. van; Bertolotto, G.

    2007-01-01

    The joint European project "UUV Covert Acoustic Communications" explores methods for underwater communication at low signal-to-noise ratios. The first phase of the project focuses on characterization of the communication channel. Sea trials were conducted in two littoral environments in September

  9. Reduction of MRI signal distortion from titanium intracavitary brachytherapy applicator by optimizing pulse sequence parameters.

    Science.gov (United States)

    Sullivan, Thomas P; Harkenrider, Matthew M; Surucu, Murat; Wood, Abbie M; Yacoub, Joseph H; Shea, Steven M

    2017-11-22

    To demonstrate that optimized pulse sequence parameters for a T2-weighted (T2w) fast spin echo acquisition reduced artifacts from a titanium brachytherapy applicator compared to conventional sequence parameters. Following Institutional Review Board approval and informed consent, seven patients were successfully imaged with both standard sagittal T2w fast spin echo parameters (voxel size of 0.98 × 0.78 × 4.0 mm 3 ; readout bandwidth of 200 Hz/px; repetition time of 2800 ms; echo time of 91 ms; echo train length of 15; 36 slices; and imaging time of 3:16 min) and an additional optimized T2w sequence (voxel size of 0.98 × 0.98 × 4.0 mm 3 ; readout bandwidth of 500 Hz/px; repetition time of 3610 ms; echo time of 91 ms; echo train length of 25; 18-36 slices; and imaging time of 1:15-2:30 min), which had demonstrated artifact reduction in prior phantom work. Visualized intracavitary tandem was hand-segmented by two of the authors. Three body imaging radiologists assessed image quality and intraobserver agreement scores were analyzed. The average segmented volume of the intracavitary applicator significantly (p parameters as compared to the standard pulse sequence. Comparison of experimental and standard T2w sequence qualitative scores for each reviewer showed no significant differences between the two techniques. This study demonstrated that pulse sequence parameter optimization can significantly reduce distortion artifact from titanium applicators while maintaining image quality and reasonable imaging times. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  10. Normal Evoked Response to Rapid Sequences of Tactile Pulses in Autism Spectrum Disorders

    Directory of Open Access Journals (Sweden)

    Santosh Ganesan

    2016-09-01

    Full Text Available Autism spectrum disorder (ASD is a developmental disorder diagnosed behaviorally, with many documented neurophysiological abnormalities in cortical response properties. While abnormal sensory processing is not considered core to the disorder, most ASD individuals report sensory processing abnormalities. Yet, the neurophysiological correlates of these abnormalities have not been fully mapped. In the auditory domain, studies have shown that cortical responses in the early auditory cortex in ASD are abnormal in multiple ways. In particular, it has been shown that individuals with ASD who were also language impaired, have abnormal cortical auditory evoked responses to rapid, but not slow, sequences of tones. Here, we tested the somatosensory domain in ASD for abnormalities in rapid processing of tactile pulses, to determine whether abnormalities there parallel those observed in the auditory domain. Specifically, we tested the somatosensory cortex response to a sequence of two tactile pulses with different (short and long temporal separation. We analyzed the responses in cortical space, in primary somatosensory cortex. As expected, we found no group difference in the evoked response to pulses with long temporal separation. Contrary to findings in the auditory domain and to our hypothesis, we also found no group differences in the evoked responses to the sequence with a short temporal separation. These results suggest that rapid temporal processing deficits in ASD are not generalized across multiple sensory domains, and are unlikely to underlie the behavioral somatosensory abnormalities observed in ASD.

  11. An improved pulse sequence and inversion algorithm of T2 spectrum

    Science.gov (United States)

    Ge, Xinmin; Chen, Hua; Fan, Yiren; Liu, Juntao; Cai, Jianchao; Liu, Jianyu

    2017-03-01

    The nuclear magnetic resonance transversal relaxation time is widely applied in geological prospecting, both in laboratory and downhole environments. However, current methods used for data acquisition and inversion should be reformed to characterize geological samples with complicated relaxation components and pore size distributions, such as samples of tight oil, gas shale, and carbonate. We present an improved pulse sequence to collect transversal relaxation signals based on the CPMG (Carr, Purcell, Meiboom, and Gill) pulse sequence. The echo spacing is not constant but varies in different windows, depending on prior knowledge or customer requirements. We use the entropy based truncated singular value decomposition (TSVD) to compress the ill-posed matrix and discard small singular values which cause the inversion instability. A hybrid algorithm combining the iterative TSVD and a simultaneous iterative reconstruction technique is implemented to reach the global convergence and stability of the inversion. Numerical simulations indicate that the improved pulse sequence leads to the same result as CPMG, but with lower echo numbers and computational time. The proposed method is a promising technique for geophysical prospecting and other related fields in future.

  12. SCALE-PWI: A pulse sequence for absolute quantitative cerebral perfusion imaging.

    Science.gov (United States)

    Srour, Jessy Mouannes; Shin, Wanyong; Shah, Saurabh; Sen, Anindya; Carroll, Timothy J

    2011-05-01

    The Bookend technique is a magnetic resonance imaging (MRI) dynamic susceptibility contrast method that provides reliable quantitative measurement of cerebral blood flow (CBF) and cerebral blood volume (CBV). The quantification is patient specific, is derived from a steady-state measurement of CBV, and is obtained from T(1) changes in the white matter and the blood pool after contrast agent injection. In the current implementation, the Bookend technique consists of three scanning steps requiring a cumulative scan time of 3 minutes 47 seconds, a well-trained technologist, and extra time for offline image reconstruction. We present an automation and acceleration of the multiscan Bookend protocol through a self-calibrating pulse sequence, namely Self-Calibrated Epi Perfusion-Weighted Imaging (SCALE-PWI). The SCALE-PWI is a single-shot echo-planar imaging pulse sequence with three modules and a total scan time of under 2 minutes. It provides the possibility of performing online, quantitative perfusion image reconstruction, which reduces the latency to obtain quantitative maps. A validation study in healthy volunteers (N=19) showed excellent agreement between SCALE-PWI and the conventional Bookend protocol (P>0.05 with Student's t-test, r=0.95/slope=0.98 for quantitative CBF, and r=0.91/slope=0.94 for quantitative CBV). A single MRI pulse sequence for absolute quantification of cerebral perfusion has been developed.

  13. Influence of pseudorandom bit format on the direct modulation ...

    Indian Academy of Sciences (India)

    The differences in the relative contributions of the intrinsic noise of the laser and the pseudorandom bit-pattern effect to the modulation characteristics are presented. We introduce an approximate estimation to the transient properties that control the digital modulation performance, namely, the modulation bit rate and the ...

  14. Efficient Quantum Pseudorandomness with Nearly Time-Independent Hamiltonian Dynamics

    Directory of Open Access Journals (Sweden)

    Yoshifumi Nakata

    2017-04-01

    Full Text Available Quantum randomness is an essential key to understanding the dynamics of complex many-body systems and also a powerful tool for quantum engineering. However, exact realizations of quantum randomness take an extremely long time and are infeasible in many-body systems, leading to the notion of quantum pseudorandomness, also known as unitary designs. Here, to explore microscopic dynamics of generating quantum pseudorandomness in many-body systems, we provide new efficient constructions of unitary designs and propose a design Hamiltonian, a random Hamiltonian of which dynamics always forms a unitary design after a threshold time. The new constructions are based on the alternate applications of random potentials in the generalized position and momentum spaces, and we provide explicit quantum circuits generating quantum pseudorandomness significantly more efficient than previous ones. We then provide a design Hamiltonian in disordered systems with periodically changing spin-glass-type interactions. The design Hamiltonian generates quantum pseudorandomness in a constant time even in the system composed of a large number of spins. We also point out the close relationship between the design Hamiltonian and quantum chaos.

  15. Optimizing symmetry-based recoupling sequences in solid-state NMR by pulse-transient compensation and asynchronous implementation.

    Science.gov (United States)

    Hellwagner, Johannes; Sharma, Kshama; Tan, Kong Ooi; Wittmann, Johannes J; Meier, Beat H; Madhu, P K; Ernst, Matthias

    2017-06-28

    Pulse imperfections like pulse transients and radio-frequency field maladjustment or inhomogeneity are the main sources of performance degradation and limited reproducibility in solid-state nuclear magnetic resonance experiments. We quantitatively analyze the influence of such imperfections on the performance of symmetry-based pulse sequences and describe how they can be compensated. Based on a triple-mode Floquet analysis, we develop a theoretical description of symmetry-based dipolar recoupling sequences, in particular, R26411, calculating first- and second-order effective Hamiltonians using real pulse shapes. We discuss the various origins of effective fields, namely, pulse transients, deviation from the ideal flip angle, and fictitious fields, and develop strategies to counteract them for the restoration of full transfer efficiency. We compare experimental applications of transient-compensated pulses and an asynchronous implementation of the sequence to a supercycle, SR26, which is known to be efficient in compensating higher-order error terms. We are able to show the superiority of R26 compared to the supercycle, SR26, given the ability to reduce experimental error on the pulse sequence by pulse-transient compensation and a complete theoretical understanding of the sequence.

  16. A Bidirectional Generalized Synchronization Theorem-Based Chaotic Pseudo-random Number Generator

    Directory of Open Access Journals (Sweden)

    Han Shuangshuang

    2013-07-01

    Full Text Available Based on a bidirectional generalized synchronization theorem for discrete chaos system, this paper introduces a new 5-dimensional bidirectional generalized chaos synchronization system (BGCSDS, whose prototype is a novel chaotic system introduced in [12]. Numerical simulation showed that two pair variables of the BGCSDS achieve generalized chaos synchronization via a transform H.A chaos-based pseudo-random number generator (CPNG was designed by the new BGCSDS. Using the FIPS-140-2 tests issued by the National Institute of Standard and Technology (NIST verified the randomness of the 1000 binary number sequences generated via the CPNG and the RC4 algorithm respectively. The results showed that all the tested sequences passed the FIPS-140-2 tests. The confidence interval analysis showed the statistical properties of the randomness of the sequences generated via the CPNG and the RC4 algorithm do not have significant differences.

  17. Development of Nuclear Magnetic Resonance Pulse Sequences and Probes to Study Biomacromolecules

    Energy Technology Data Exchange (ETDEWEB)

    Cosman, M; Krishnan, V V; Maxwell, R

    2001-02-26

    The determination of the three dimensional structures at high resolution of biomolecules, such as proteins and nucleic acids, enables us to understand their function at the molecular level. At the present time, there are only two methods available for determining such structures, nuclear magnetic resonance (NMR) spectroscopy and X-ray diffraction. Compared to well-established X-ray diffraction techniques, NMR methodology is relatively new and has many areas in which improvement can still be attained. In this project, we focused on the development of new NMR probes and pulse sequences that were tailored to tackle specific problems that are not adequately addressed by current technology. Probes are the hardware that contain the radio frequency (RF) circuitry used to both excite and detect the NMR signals. Pulse sequences are composed of a series of RF pulses and delays, which are applied to the sample held within the magnetic field by the probe, so as to manipulate the nuclear spins. Typically, a probe is developed for a specific set of nuclei and types of experiments and the pulse sequences are then written to use the probe in an optimal manner. In addition, the inter-development of instrumentation and methods are determined by the specific biological question to be examined. Thus our efforts focused on addressing an area of importance in NMR Structural Biology namely more effective ways to use the phosphorus ({sup 31}P) nucleus. Phosphorus is a very important biological element that is strategically located in nucleic acids, where it imparts negative charge and flexibility to RNA and DNA. It is also a component of the cellular membrane and thus interacts with membrane proteins. It is used in mechanisms to signal, activate or deactivate enzymes; and participates in energy storage and release. However, the phosphorus nucleus exhibits certain properties, such as poor spectral dispersion, low sensitivity of detection, and fast relaxation, which limit its effective use

  18. Microscopic imaging of slow flow and diffusion: a pulsed field gradient stimulated echo sequence combined with turbo spin echo imaging

    NARCIS (Netherlands)

    Scheenen, T.W.J.; Vergeldt, F.J.; Windt, C.W.; Jager, de P.A.; As, van H.

    2001-01-01

    In this paper we present a pulse sequence that combines a displacement-encoded stimulated echo with rapid sampling of k-space by means of turbo spin echo imaging. The stimulated echo enables the use of long observation times between the two pulsed field gradients that sample q-space completely.

  19. Influence of potential pulses amplitude sequence in a voltammetric electronic tongue (VET) applied to assess antioxidant capacity in aliso.

    Science.gov (United States)

    Fuentes, Esteban; Alcañiz, Miguel; Contat, Laura; Baldeón, Edwin O; Barat, José M; Grau, Raúl

    2017-06-01

    Four signals configurations were studied, two of them built by small increases of potential and two with bigger increments. The highest current values were obtained when pulses with bigger change of potential were used although the best results were shown by the pulse sequence which included an intermediate pulse before the relevant pulse. A mathematical model based on trolox pattern was developed to predict antioxidant capacity of aliso, employing information obtained from all the electrodes, although model validation could be done only employing the information from gold electrode. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Performance of selected coded direct-sequence receiver structures in pulsed interference

    Science.gov (United States)

    Matis, K. R.; Modestino, J. W.

    The performance of short constraint-length convolutional codes are considered in conjunction with coherent BPSK direct-sequence spread-spectrum modulation in a variety of pulsed interference scenarios. The use of several types of imperfect interference estimation mechanisms, and the resulting impact on Viterbi decoder bit error probability performance, are considered. The digital receiver structures eliminate the need for a fast-acting analog AGC circuit, which is often susceptible to spoofing. For the short constraint-length codes under consideration, upper bounds are provided on bit error probability performance under idealized channel modeling assumptions. Departures from these idealized assumptions are analyzed through extensive Monte-Carlo computer simulation.

  1. Update on MRI Pulse Sequences for the Knee: Imaging of Cartilage, Meniscus, Tendon, and Hardware.

    Science.gov (United States)

    Ariyachaipanich, Aticha; Bae, Won C; Statum, Sheronda; Chung, Christine B

    2017-04-01

    Magnetic resonance imaging (MRI) is widely used in the clinical setting as well as for research applications. Since its inception, technical development has broadly progressed as a response to challenges in both the clinical and research settings. Higher magnetic field strength and advances in hardware and software have revolutionized the diagnostic potential of MRI and moved well beyond diagnosis to characterization of tissue metabolism, biochemistry, disease pathogenesis, and material property, to name a few. This article focuses on state-of-the-art clinical and cutting-edge novel pulse sequences applied to knee MRI. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  2. Generation of a sequence of frequency-modulated pulses in longitudinally inhomogeneous optical waveguides

    Science.gov (United States)

    Zolotovskii, I. O.; Lapin, V. A.; Sementsov, D. I.; Stolyarov, D. A.

    2017-03-01

    The conditions for the generation and efficient amplification of frequency-modulated soliton-like wave packets in longitudinally inhomogeneous active optical waveguides have been studied. The possibility of forming a sequence of pico- and subpicosecond pulses from quasi-continuous radiation in active and passive optical waveguides with the group-velocity dispersion (GVD) changing over the waveguide length is considered. The behavior of a wave packet in the well-developed phase of modulation instability with a change in the waveguide inhomogeneity parameters has been investigated based on the numerical analysis.

  3. Effects of reverberations and clutter filtering in pulsed Doppler using sparse sequences.

    Science.gov (United States)

    Avdal, Jørgen; Lovstakken, Lasse; Torp, Hans

    2015-05-01

    Duplex ultrasound is a modality in which an ultrasound system is used for simultaneous acquisition of both B-mode images and velocity (Doppler) data. Conventional duplex sequences interleave packets of B-mode and Doppler transmissions, producing undesirable gaps during B-mode interruptions. In recent years, several techniques have been proposed for avoiding such gaps by using sparse sequences, in which velocity spectra are generated from nonuniformly sampled Doppler data containing frequent B-mode interruptions. In this work, two negative effects are discussed that may influence velocity estimation when using nonuniformly sampled sequences. First, it is shown that long reverberation times lead to discontinuities in the signal from stationary clutter after each B-mode interruption. Second, using frequency analysis, it is shown that clutter filtering of nonuniformly sampled data may introduce artifacts in the velocity spectrum, and also lead to significant bias in mean velocity estimates. Methods are presented for quantification of these effects, and utilized to analyze three types of sparse duplex sequences for blood velocity estimation. In particular, it is argued that the use of such sequences in cardiac applications is not recommended because of long reverberation time. Additionally, it is found that the use of regression filters to filter nonuniformly sampled data may produce significant artifacts in pulsed wave Doppler spectra, but is less significant for color Doppler imaging applications. In vitro and in vivo examples are included showing the presence and magnitude of these problems in clinically relevant applications.

  4. Chaos-based Pseudo-random Number Generation

    KAUST Repository

    Barakat, Mohamed L.

    2014-04-10

    Various methods and systems related to chaos-based pseudo-random number generation are presented. In one example, among others, a system includes a pseudo-random number generator (PRNG) to generate a series of digital outputs and a nonlinear post processing circuit to perform an exclusive OR (XOR) operation on a first portion of a current digital output of the PRNG and a permutated version of a corresponding first portion of a previous post processed output to generate a corresponding first portion of a current post processed output. In another example, a method includes receiving at least a first portion of a current output from a PRNG and performing an XOR operation on the first portion of the current PRNG output with a permutated version of a corresponding first portion of a previous post processed output to generate a corresponding first portion of a current post processed output.

  5. A Multi-Threaded Cryptographic Pseudorandom Number Generator Test Suite

    Science.gov (United States)

    2016-09-01

    Cloud GSL GNU scientific library KSTEST Kolmogorov-Smirnov test NIST National Institute for Standards and Technology OpenMP Open Multi-Processing OTP...one-time pad POSIX Portable Operating System Interface PRNG pseudorandom number generator RA resolve ambiguity RNG random number generator SSH secure...chats of Cryptocat due to a programming flaw [1]. A bug in the BigInt library caused the random number generator to have a slight bias when generating

  6. Discriminatory usefulness of pulsed-field gel electrophoresis and sequence-based typing in Legionella outbreaks.

    Science.gov (United States)

    Quero, Sara; García-Núñez, Marian; Párraga-Niño, Noemí; Barrabeig, Irene; Pedro-Botet, Maria L; de Simon, Mercè; Sopena, Nieves; Sabrià, Miquel

    2016-06-01

    To compare the discriminatory power of pulsed-field gel electrophoresis (PFGE) and sequence-based typing (SBT) in Legionella outbreaks for determining the infection source. Twenty-five investigations of Legionnaires' disease were analyzed by PFGE, SBT and Dresden monoclonal antibody. The results suggested that monoclonal antibody could reduce the number of Legionella isolates to be characterized by molecular methods. The epidemiological concordance PFGE-SBT was 100%, while the molecular concordance was 64%. Adjusted Wallace index (AW) showed that PFGE has better discriminatory power than SBT (AWSBT→PFGE = 0.767; AWPFGE→SBT = 1). The discrepancies appeared mostly in sequence type (ST) 1, a worldwide distributed ST for which PFGE discriminated different profiles. SBT discriminatory power was not sufficient verifying the infection source, especially in worldwide distributed STs, which were classified into different PFGE patterns.

  7. Comparison of different pulse sequences for in vivo determination of T1 relaxation times in the human brain

    DEFF Research Database (Denmark)

    Kjaer, L; Henriksen, O

    1988-01-01

    ). T1 measurements were performed on the human brain using a whole body MR scanner operating at 1.5 tesla. Three different pulse sequences were compared including two 6-points inversion recovery (IR) sequences with TR = 2.0 s and 4.0, respectively, and a 12-points partial saturation inversion recovery...

  8. Comparison of MRI pulse sequences for investigation of lesions of the cervical spinal cord

    Energy Technology Data Exchange (ETDEWEB)

    Campi, A.; Pontesilli, S.; Gerevini, S.; Scotti, G. [San Raffaele Hospital, Milan (Italy). Dept. of Neuroradiology

    2000-09-01

    Small spinal cord lesions, even if clinically significant, can be due to the low sensitivity of some pulse sequences. We compared T2-weighted fast (FSE), and conventional (CSE) spin-echo and short-tau inversion-recovery (STIR)-FSE overlooked on MRI sequences to evaluate their sensitivity to and specificity for lesions of different types. We compared the three sequences in MRI of 57 patients with cervical spinal symptoms. The image sets were assessed by two of us individually for final diagnosis, lesion detectability and image quality. Both readers arrived at the same final diagnoses with all sequences, differentiating four groups of patients. Group 1 (30 patients, 53 %), with a final diagnosis of multiple sclerosis (MS). Demyelinating lesions were better seen on STIR-FSE images, on which the number of lesions was significantly higher than on FSE, while the FSE and CSE images showed approximately equal numbers of lesions; additional lesions were found in 9 patients. The contrast-to-noise ratio (CNR) of 17 demyelinating lesions was significantly higher on STIR-FSE images than with the other sequences. Group 2, 19 patients (33 %) with cervical pain, 15 of whom had disc protrusion or herniation: herniated discs were equally well delineated with all sequences, with better myelographic effect on FSE. In five patients with intrinsic spinal cord abnormalities, the conspicuity and demarcation of the lesions were similar with STIR-FSE and FSE. Group 3, 4 patients (7 %) with acute myelopathy of unknown aetiology. In two patients, STIR-FSE gave better demarcation of lesions and in one a questionable additional lesions. Group 4, 4 patients (7 %) with miscellaneous final diagnoses. STIR-FSE had high sensitivity to demyelinating lesions, can be considered quite specific and should be included in spinal MRI for assessment of suspected demyelinating disease. (orig.)

  9. MOLLI and AIR T1 mapping pulse sequences yield different myocardial T1 and ECV measurements.

    Science.gov (United States)

    Hong, KyungPyo; Kim, Daniel

    2014-11-01

    Both post-contrast myocardial T1 and extracellular volume (ECV) have been reported to be associated with diffuse interstitial fibrosis. Recently, the cardiovascular magnetic resonance (CMR) field is recognizing that post-contrast myocardial T1 is sensitive to several confounders and migrating towards ECV as a measure of collagen volume fraction. Several recent studies using widely available Modified Look-Locker Inversion-recovery (MOLLI) have reported ECV cutoff values to distinguish between normal and diseased myocardium. It is unclear if these cutoff values are translatable to different T1 mapping pulse sequences such as arrhythmia-insensitive-rapid (AIR) cardiac T1 mapping, which was recently developed to rapidly image patients with cardiac rhythm disorders. We sought to evaluate, in well-controlled canine and pig experiments, the relative accuracy and precision, as well as intra- and inter-observer variability in data analysis, of ECV measured with AIR as compared with MOLLI. In 16 dogs, as expected, the mean T1 was significantly different (p ECV between MOLLI (21.8 ± 2.1%) and AIR (19.6 ± 2.4%) was also significantly different (p ECV calculations were similar between MOLLI and AIR. In six pigs, the coefficient of repeatability (CR), as defined by the Bland-Altman analysis, in T1 calculation was considerably lower for MOLLI (32.5 ms) than AIR (82.3 ms), and the CR in ECV calculation was also lower for MOLLI (1.8%) than AIR (4.5%). In conclusion, this study shows that MOLLI and AIR yield significantly different T1 and ECV values in large animals and that MOLLI yields higher precision than AIR. Findings from this study suggest that CMR researchers must consider the specific pulse sequence when translating published ECV cutoff values into their own studies. Copyright © 2014 John Wiley & Sons, Ltd.

  10. On pseudorandom generators in NC0

    DEFF Research Database (Denmark)

    Cryan, Mary; Miltersen, Peter Bro

    2001-01-01

    In this paper we consider the question of whether NC 0 circuits can generate pseudorandom distributions. While we leave the general question unanswered, we show – • Generators computed by NC 0 circuits where each output bit depends on at most 3 input bits (i.e, DNC 3 0 circuits) and with stretch....... – • There is an NC 4 0 generator with a super-linear stretch that passes the linear dependency test as well as k-wise independence tests, for any constant k....

  11. A Family of Controllable Cellular Automata for Pseudorandom Number Generation

    OpenAIRE

    Guan, SU; Zhang, S.

    2002-01-01

    In this paper, we present a family of novel Pseudorandom Number Generators (PRNGs) based on Controllable Cellular Automata (CCA) ─ CCA0, CCA1, CCA2 (NCA), CCA3 (BCA), CCA4 (asymmetric NCA), CCA5, CCA6 and CCA7 PRNGs. The ENT and DIEHARD test suites are used to evaluate the randomness of these CCA PRNGs. The results show that their randomness is better than that of conventional CA and PCA PRNGs while they do not lose the structure simplicity of 1-d CA. Moreover, their randomness can be compara...

  12. Investigation of timing effects in modified composite quadrupolar echo pulse sequences by mean of average Hamiltonian theory

    Science.gov (United States)

    Mananga, Eugene Stephane

    2018-01-01

    The utility of the average Hamiltonian theory and its antecedent the Magnus expansion is presented. We assessed the concept of convergence of the Magnus expansion in quadrupolar spectroscopy of spin-1 via the square of the magnitude of the average Hamiltonian. We investigated this approach for two specific modified composite pulse sequences: COM-Im and COM-IVm. It is demonstrated that the size of the square of the magnitude of zero order average Hamiltonian obtained on the appropriated basis is a viable approach to study the convergence of the Magnus expansion. The approach turns to be efficient in studying pulse sequences in general and can be very useful to investigate coherent averaging in the development of high resolution NMR technique in solids. This approach allows comparing theoretically the two modified composite pulse sequences COM-Im and COM-IVm. We also compare theoretically the current modified composite sequences (COM-Im and COM-IVm) to the recently published modified composite pulse sequences (MCOM-I, MCOM-IV, MCOM-I_d, MCOM-IV_d).

  13. Pulsed magnetization transfer contrast MRI by a sequence with water selective excitation

    Energy Technology Data Exchange (ETDEWEB)

    Schick, F. [Univ. of Tuebingen (Germany)

    1996-01-01

    A water selective SE imaging sequence was developed providing suitable properties for the assessment of magnetization transfer (MT) effects in tissues with considerable amounts of fat. The sequence with water selective excitation and slice selective refocusing combines the following features: The RIF exposure on the macromolecular protons is relatively low for single slice imaging without MT prepulses, since no additional pulses for fat saturation are necessary. Water selection by frequency selective excitation diminishes faults in the subtraction of images recorded with and without MT prepulses (which might arise from movements). High differences in the signal amplitudes from hyaline cartilage and muscle tissue were obtained comparing images recorded with irradiation of the series of prepulses for MT and those lacking MT prepulses. Utilizations of the described water selective approach for the assessment of MT effects in lesions of cartilage and bone are demonstrated. MT saturation was also examined in muscles with fatty degeneration of patients suffering from progressive muscular dystrophy. The described technique allows determination of MT effects with good precision in a single slice, especially in regions with dominating fat signals. 22 refs., 5 figs.

  14. Algorithm for generation pseudo-random series with arbitrarily assigned distribution law

    Directory of Open Access Journals (Sweden)

    В.С. Єременко

    2005-04-01

    Full Text Available  Method for generation pseudo-random series with arbitrarily assigned distribution law has been proposed. The praxis of using proposed method for generation pseudo-random series with anti-modal and approximate to Gaussian distribution law has been investigated.

  15. Multilocus Sequence Typing Scheme versus Pulsed-Field Gel Electrophoresis for Typing Mycobacterium abscessus Isolates

    Science.gov (United States)

    Machado, Gabriel Esquitini; Matsumoto, Cristianne Kayoko; Chimara, Erica; Duarte, Rafael da Silva; de Freitas, Denise; Palaci, Moises; Hadad, David Jamil; Lima, Karla Valéria Batista; Lopes, Maria Luiza; Ramos, Jesus Pais; Campos, Carlos Eduardo; Caldas, Paulo César; Heym, Beate

    2014-01-01

    Outbreaks of infections by rapidly growing mycobacteria following invasive procedures, such as ophthalmological, laparoscopic, arthroscopic, plastic, and cardiac surgeries, mesotherapy, and vaccination, have been detected in Brazil since 1998. Members of the Mycobacterium chelonae-Mycobacterium abscessus group have caused most of these outbreaks. As part of an epidemiological investigation, the isolates were typed by pulsed-field gel electrophoresis (PFGE). In this project, we performed a large-scale comparison of PFGE profiles with the results of a recently developed multilocus sequence typing (MLST) scheme for M. abscessus. Ninety-three isolates were analyzed, with 40 M. abscessus subsp. abscessus isolates, 47 M. abscessus subsp. bolletii isolates, and six isolates with no assigned subspecies. Forty-five isolates were obtained during five outbreaks, and 48 were sporadic isolates that were not associated with outbreaks. For MLST, seven housekeeping genes (argH, cya, glpK, gnd, murC, pta, and purH) were sequenced, and each isolate was assigned a sequence type (ST) from the combination of obtained alleles. The PFGE patterns of DraI-digested DNA were compared with the MLST results. All isolates were analyzable by both methods. Isolates from monoclonal outbreaks showed unique STs and indistinguishable or very similar PFGE patterns. Thirty-three STs and 49 unique PFGE patterns were identified among the 93 isolates. The Simpson's index of diversity values for MLST and PFGE were 0.69 and 0.93, respectively, for M. abscessus subsp. abscessus and 0.96 and 0.97, respectively, for M. abscessus subsp. bolletii. In conclusion, the MLST scheme showed 100% typeability and grouped monoclonal outbreak isolates in agreement with PFGE, but it was less discriminative than PFGE for M. abscessus. PMID:24899019

  16. Feasibility of pulse wave velocity estimation from low frame rate US sequences in vivo

    Science.gov (United States)

    Zontak, Maria; Bruce, Matthew; Hippke, Michelle; Schwartz, Alan; O'Donnell, Matthew

    2017-03-01

    The pulse wave velocity (PWV) is considered one of the most important clinical parameters to evaluate CV risk, vascular adaptation, etc. There has been substantial work attempting to measure the PWV in peripheral vessels using ultrasound (US). This paper presents a fully automatic algorithm for PWV estimation from the human carotid using US sequences acquired with a Logic E9 scanner (modified for RF data capture) and a 9L probe. Our algorithm samples the pressure wave in time by tracking wall displacements over the sequence, and estimates the PWV by calculating the temporal shift between two sampled waves at two distinct locations. Several recent studies have utilized similar ideas along with speckle tracking tools and high frame rate (above 1 KHz) sequences to estimate the PWV. To explore PWV estimation in a more typical clinical setting, we used focused-beam scanning, which yields relatively low frame rates and small fields of view (e.g., 200 Hz for 16.7 mm filed of view). For our application, a 200 Hz frame rate is low. In particular, the sub-frame temporal accuracy required for PWV estimation between locations 16.7 mm apart, ranges from 0.82 of a frame for 4m/s, to 0.33 for 10m/s. When the distance is further reduced (to 0.28 mm between two beams), the sub-frame precision is in parts per thousand (ppt) of the frame (5 ppt for 10m/s). As such, the contributions of our algorithm and this paper are: 1. Ability to work with low frame-rate ( 200Hz) and decreased lateral field of view. 2. Fully automatic segmentation of the wall intima (using raw RF images). 3. Collaborative Speckle Tracking of 2D axial and lateral carotid wall motion. 4. Outlier robust PWV calculation from multiple votes using RANSAC. 5. Algorithm evaluation on volunteers of different ages and health conditions.

  17. Multishot versus single-shot pulse sequences in very high field fMRI: a comparison using retinotopic mapping.

    Directory of Open Access Journals (Sweden)

    Jascha D Swisher

    Full Text Available High-resolution functional MRI is a leading application for very high field (7 Tesla human MR imaging. Though higher field strengths promise improvements in signal-to-noise ratios (SNR and BOLD contrast relative to fMRI at 3 Tesla, these benefits may be partially offset by accompanying increases in geometric distortion and other off-resonance effects. Such effects may be especially pronounced with the single-shot EPI pulse sequences typically used for fMRI at standard field strengths. As an alternative, one might consider multishot pulse sequences, which may lead to somewhat lower temporal SNR than standard EPI, but which are also often substantially less susceptible to off-resonance effects. Here we consider retinotopic mapping of human visual cortex as a practical test case by which to compare examples of these sequence types for high-resolution fMRI at 7 Tesla. We performed polar angle retinotopic mapping at each of 3 isotropic resolutions (2.0, 1.7, and 1.1 mm using both accelerated single-shot 2D EPI and accelerated multishot 3D gradient-echo pulse sequences. We found that single-shot EPI indeed led to greater temporal SNR and contrast-to-noise ratios (CNR than the multishot sequences. However, additional distortion correction in postprocessing was required in order to fully realize these advantages, particularly at higher resolutions. The retinotopic maps produced by both sequence types were qualitatively comparable, and showed equivalent test/retest reliability. Thus, when surface-based analyses are planned, or in other circumstances where geometric distortion is of particular concern, multishot pulse sequences could provide a viable alternative to single-shot EPI.

  18. Comparison of different pulse sequences for in vivo determination of T1 relaxation times in the human brain

    DEFF Research Database (Denmark)

    Kjaer, L; Henriksen, O

    1988-01-01

    ). T1 measurements were performed on the human brain using a whole body MR scanner operating at 1.5 tesla. Three different pulse sequences were compared including two 6-points inversion recovery (IR) sequences with TR = 2.0 s and 4.0, respectively, and a 12-points partial saturation inversion recovery...... (PSIR) sequence with TR varying between 0.24 and 8.0 s. The median T1 relaxation times obtained in cortical grey matter and cerebrospinal fluid were significantly shorter in the IR experiments at TR = 2 s than in those carried out at TR = 4 s. Concerning white matter the discrepancy was much less...

  19. Detection of Subarachnoid Hemorrhage at Acute and Subacute/Chronic Stages: Comparison of Four Magnetic Resonance Imaging Pulse Sequences and Computed Tomography

    Directory of Open Access Journals (Sweden)

    Mei-Kang Yuan

    2005-03-01

    Conclusion: FLAIR and GE T2* MRI pulse sequences, and CT scans, are all statistically significant indicators of acute SAH. GE T2*-weighted images are statistically significant indicators of subacute-to-chronic SAH, whereas other MRI pulse sequences, and CT scans, are not.

  20. Noise analysis in fast magnetic resonance electrical impedance tomography (MREIT) based on spoiled multi gradient echo (SPMGE) pulse sequence.

    Science.gov (United States)

    Oh, Tong In; Jeong, Woo Chul; Kim, Ji Eun; Sajib, Saurav Z K; Kim, Hyung Joong; Kwon, Oh In; Woo, Eung Je

    2014-08-21

    Magnetic resonance electrical impedance tomography (MREIT) is a promising non-invasive method to visualize a static cross-sectional conductivity and/or current density image by injecting low frequency currents. MREIT measures one component of the magnetic flux density caused by the injected current using a magnetic resonance (MR) scanner. For practical in vivo implementations of MREIT, especially for soft biological tissues where the MR signal rapidly decays, it is crucial to develop a technique for optimizing the magnetic flux density signal by the injected current while maintaining spatial-resolution and contrast. We design an MREIT pulse sequence by applying a spoiled multi-gradient-echo pulse sequence (SPMGE) to the injected current nonlinear encoding (ICNE), which fully injects the current at the end of the read-out gradient. The applied ICNE-SPMGE pulse sequence maximizes the duration of injected current almost up to a repetition time by measuring multiple magnetic flux density data. We analyze the noise level of measured magnetic flux density with respect to the pulse width of injection current and T*(2) relaxation time. In due consideration of the ICNE-SPMGE pulse sequence, using a reference information of T*(2) values in a local region of interest by a short pre-scan data, we predict the noise level of magnetic flux density to be measured for arbitrary repetition time TR. Results from phantom experiment demonstrate that the proposed method can predict the noise level of magnetic flux density for an appropriate TR = 40 ms using a reference scan for TR = 75 ms. The predicted noise level was compared with the noise level of directly measured magnetic flux density data.

  1. Quantum-key-distribution protocol with pseudorandom bases

    Science.gov (United States)

    Trushechkin, A. S.; Tregubov, P. A.; Kiktenko, E. O.; Kurochkin, Y. V.; Fedorov, A. K.

    2018-01-01

    Quantum key distribution (QKD) offers a way for establishing information-theoretical secure communications. An important part of QKD technology is a high-quality random number generator for the quantum-state preparation and for post-processing procedures. In this work, we consider a class of prepare-and-measure QKD protocols, utilizing additional pseudorandomness in the preparation of quantum states. We study one of such protocols and analyze its security against the intercept-resend attack. We demonstrate that, for single-photon sources, the considered protocol gives better secret key rates than the BB84 and the asymmetric BB84 protocols. However, the protocol strongly requires single-photon sources.

  2. Pseudo-random Spray Release to Measure World-wide Transfer Functions of Cloud Albedo Control.

    Science.gov (United States)

    Salter, Stephen

    2010-05-01

    Institute for Energy Systems, School of Engineering, University of Edinburgh. S.Salter@ed.ac.uk Previous climate models of Latham's proposal to reverse global warming by using sub-micron sea spray to increase cloud albedo have used a variety of spray patterns. Kettles forced CCN concentration to be 375/cm3 everywhere. Rasch et al used the 20% and 70% most susceptible regions. Bala and Caldeira used an even spread. Jones et al. concentrated spray in the 3.3% oceans with the highest susceptibility All used the same rate through the year. We want to choose a scheme for a climate-modelling experiment designed to identify simultaneously the effects of cloud albedo control at various seasons of the year from spray at all regions of the world on climates of all other regions the world. In particular we want to know seasons and spray places which might have an undesirable effect on precipitation. The spray systems in various regions of a numerical climate model will be modulated on an off with different but known pseudo-random sequences and a selection of seasons. The mean value of the resulting weather records of the parameters of interest, mainly temperature and water run-off, at each region will be subtracted from each value of the record so as to give just the alternating component with an average value of zero. This will be correlated with each of the chosen pseudo-random sequences to give the magnitude and polarity of the effect of a treatment at each input area and selected seasons of the year with the resulting effects on all regions. By doing a time-shifted correlation we can account for phase-shift and time delay. The signal-to-noise ratio should improve with the square root of the analysis time and so we may be able to measure the transfer function with quite a small stimulus. The results of a Mathcad simulation of the process with statistical distributions approximating to natural variations temperature and precipitation show that a single run of a climate

  3. Optimization of multi-pulse sequences for nonlinear contrast agent imaging using a cMUT array.

    Science.gov (United States)

    Novell, Anthony; Arena, Christopher B; Kasoji, Sandeep; Dayton, Paul A

    2015-04-21

    Capacitive micromachined ultrasonic transducer (cMUT) technology provides advantages such as wide frequency bandwidth, which can be exploited for contrast agent imaging. Nevertheless, the efficiency of traditional multi-pulse imaging schemes, such as pulse inversion (PI), remains limited because of the intrinsic nonlinear character of cMUTs. Recently, a new contrast imaging sequence, called bias voltage modulation sequence (BVM), has been specifically developed for cMUTs to suppress their unwanted nonlinear behavior. In this study, we propose to optimize contrast agent detection by combining the BVM sequence with PI and/or chirp reversal (CR). An aqueous dispersion of lipid encapsulated microbubbles was exposed to several combinations of multi-pulse imaging sequences. Approaches were evaluated in vitro using 9 inter-connected elements of a cMUT linear array (excitation frequency of 4 MHz; peak negative pressure of 100 kPa). For sequences using chirp excitations, a specific compression filter was designed to compress and extract several nonlinear components from the received microbubble responses. A satisfactory cancellation of the nonlinear signal from the source is achieved when BVM is combined with PI and CR. In comparison with PI and CR imaging modes alone, using sequences incorporating BVM increases the contrast-to-tissue ratio by 10.0 dB and 4.6 dB, respectively. Furthermore, the combination of BVM with CR and PI results in a significant increase of the contrast-to-noise ratio (+29 dB). This enhancement is attributed to the use of chirps as excitation signals and the improved preservation of several nonlinear components contained within the contrast agent response.

  4. Generalized Hardware Post‐processing Technique for Chaos‐Based Pseudorandom Number Generators

    National Research Council Canada - National Science Library

    Barakat, Mohamed L; Mansingka, Abhinav S; Radwan, Ahmed G; Salama, Khaled N

    2013-01-01

    ...‐based operation with rotation and feedback. The technique allows full utilization of the chaotic output as pseudorandom number generators and improves throughput without a significant area penalty...

  5. Protecting and accelerating adiabatic passage with time-delayed pulse sequences

    CERN Document Server

    Sampedro, Pablo; Sola, Ignacio R

    2016-01-01

    Using numerical simulations of two-photon electronic absorption with femtosecond pulses in Na$_2$ we show that: i) it is possible to avoid the characteristic saturation or dumped Rabi oscillations in the yield of absorption by time-delaying the laser pulses; ii) it is possible to accelerate the onset of adiabatic passage by using the vibrational coherence starting in a wave packet; and iii) it is possible to prepare the initial wave packet in order to achieve full state-selective transitions with broadband pulses. The findings can be used, for instance, to achieve ultrafast adiabatic passage by light-induced potentials and understand its intrinsic robustness.

  6. Dual-frequency tissue harmonic suppression using phase-coded pulse sequence: proof of concept using a phantom.

    Science.gov (United States)

    Shen, Che-Chou; Wang, Hui-Ting

    2013-03-01

    The presence of tissue harmonic generation during acoustic propagation is one major limitation in nonlinear detection of microbubble contrast agents. However, conventional solutions for tissue harmonic suppression are not applicable in dual-frequency (DF) harmonic imaging. In DF harmonic imaging, the second harmonic signal at second harmonic (2f(0)) frequency and the inter-modulation harmonic signal at fundamental (f(0)) frequency are simultaneously generated for imaging and both need to be suppressed to improve contrast-to-tissue ratio (CTR). In this study, a novel phase-coded pulse sequence is developed to accomplish DF tissue harmonic suppression. Phase-coded pulse sequence utilizes multiple firings with equidistant transmit phase for harmonic cancellation in the sum of respective echoes. For the f(0) transmit component, the transmit phase comes from the equidistant set of {-2π/3, 0, 2π/3} to suppress the second harmonic signal at 2f(0) frequency. Moreover, in order to provide the inter-modulation harmonic suppression at f(0) frequency, the 2f(0) transmit phase has to be particularly manipulated for the corresponding f(0) transmit phase. The proposed three-pulse sequence can remove not only the second-order harmonic signal but also other higher-order counterparts at both f(0) and 2f(0) frequencies. Measurements were performed at f(0) equal to 2.25 MHz and using hydrophone in water and contrast agents in tissue phantom. Experimental results indicate that the sequence reduces the tissue harmonic magnitude by about 20 dB along the entire axial depths and the corresponding CTR improves at both frequencies. In DF harmonic imaging, the proposed phase-coded sequence can effectively remove the tissue harmonic background at both f(0) and 2f(0) frequencies for improvement of contrast detection. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Myocardial tagging by Cardiovascular Magnetic Resonance: evolution of techniques--pulse sequences, analysis algorithms, and applications

    Science.gov (United States)

    2011-01-01

    Cardiovascular magnetic resonance (CMR) tagging has been established as an essential technique for measuring regional myocardial function. It allows quantification of local intramyocardial motion measures, e.g. strain and strain rate. The invention of CMR tagging came in the late eighties, where the technique allowed for the first time for visualizing transmural myocardial movement without having to implant physical markers. This new idea opened the door for a series of developments and improvements that continue up to the present time. Different tagging techniques are currently available that are more extensive, improved, and sophisticated than they were twenty years ago. Each of these techniques has different versions for improved resolution, signal-to-noise ratio (SNR), scan time, anatomical coverage, three-dimensional capability, and image quality. The tagging techniques covered in this article can be broadly divided into two main categories: 1) Basic techniques, which include magnetization saturation, spatial modulation of magnetization (SPAMM), delay alternating with nutations for tailored excitation (DANTE), and complementary SPAMM (CSPAMM); and 2) Advanced techniques, which include harmonic phase (HARP), displacement encoding with stimulated echoes (DENSE), and strain encoding (SENC). Although most of these techniques were developed by separate groups and evolved from different backgrounds, they are in fact closely related to each other, and they can be interpreted from more than one perspective. Some of these techniques even followed parallel paths of developments, as illustrated in the article. As each technique has its own advantages, some efforts have been made to combine different techniques together for improved image quality or composite information acquisition. In this review, different developments in pulse sequences and related image processing techniques are described along with the necessities that led to their invention, which makes this

  8. Myocardial tagging by Cardiovascular Magnetic Resonance: evolution of techniques--pulse sequences, analysis algorithms, and applications

    Directory of Open Access Journals (Sweden)

    Ibrahim El-Sayed H

    2011-07-01

    Full Text Available Abstract Cardiovascular magnetic resonance (CMR tagging has been established as an essential technique for measuring regional myocardial function. It allows quantification of local intramyocardial motion measures, e.g. strain and strain rate. The invention of CMR tagging came in the late eighties, where the technique allowed for the first time for visualizing transmural myocardial movement without having to implant physical markers. This new idea opened the door for a series of developments and improvements that continue up to the present time. Different tagging techniques are currently available that are more extensive, improved, and sophisticated than they were twenty years ago. Each of these techniques has different versions for improved resolution, signal-to-noise ratio (SNR, scan time, anatomical coverage, three-dimensional capability, and image quality. The tagging techniques covered in this article can be broadly divided into two main categories: 1 Basic techniques, which include magnetization saturation, spatial modulation of magnetization (SPAMM, delay alternating with nutations for tailored excitation (DANTE, and complementary SPAMM (CSPAMM; and 2 Advanced techniques, which include harmonic phase (HARP, displacement encoding with stimulated echoes (DENSE, and strain encoding (SENC. Although most of these techniques were developed by separate groups and evolved from different backgrounds, they are in fact closely related to each other, and they can be interpreted from more than one perspective. Some of these techniques even followed parallel paths of developments, as illustrated in the article. As each technique has its own advantages, some efforts have been made to combine different techniques together for improved image quality or composite information acquisition. In this review, different developments in pulse sequences and related image processing techniques are described along with the necessities that led to their invention

  9. PET Imaging Stability Measurements During Simultaneous Pulsing of Aggressive MR Sequences on the SIGNA PET/MR System.

    Science.gov (United States)

    Deller, Timothy W; Khalighi, Mohammad Mehdi; Jansen, Floris P; Glover, Gary H

    2018-01-01

    The recent introduction of simultaneous whole-body PET/MR scanners has enabled new research taking advantage of the complementary information obtainable with PET and MRI. One such application is kinetic modeling, which requires high levels of PET quantitative stability. To accomplish the required PET stability levels, the PET subsystem must be sufficiently isolated from the effects of MR activity. Performance measurements have previously been published, demonstrating sufficient PET stability in the presence of MR pulsing for typical clinical use; however, PET stability during radiofrequency (RF)-intensive and gradient-intensive sequences has not previously been evaluated for a clinical whole-body scanner. In this work, PET stability of the GE SIGNA PET/MR was examined during simultaneous scanning of aggressive MR pulse sequences. Methods: PET performance tests were acquired with MR idle and during simultaneous MR pulsing. Recent system improvements mitigating RF interference and gain variation were used. A fast recovery fast spin echo MR sequence was selected for high RF power, and an echo planar imaging sequence was selected for its high heat-inducing gradients. Measurements were performed to determine PET stability under varying MR conditions using the following metrics: sensitivity, scatter fraction, contrast recovery, uniformity, count rate performance, and image quantitation. A final PET quantitative stability assessment for simultaneous PET scanning during functional MRI studies was performed with a spiral in-and-out gradient echo sequence. Results: Quantitation stability of a 68Ge flood phantom was demonstrated within 0.34%. Normalized sensitivity was stable during simultaneous scanning within 0.3%. Scatter fraction measured with a 68Ge line source in the scatter phantom was stable within the range of 40.4%-40.6%. Contrast recovery and uniformity were comparable for PET images acquired simultaneously with multiple MR conditions. Peak noise equivalent count

  10. Pseudo-random dynamic address configuration (PRDAC) algorithm for mobile ad hoc networks

    Science.gov (United States)

    Wu, Shaochuan; Tan, Xuezhi

    2007-11-01

    By analyzing all kinds of address configuration algorithms, this paper provides a new pseudo-random dynamic address configuration (PRDAC) algorithm for mobile ad hoc networks. Based on PRDAC, the first node that initials this network randomly chooses a nonlinear shift register that can generates an m-sequence. When another node joins this network, the initial node will act as an IP address configuration sever to compute an IP address according to this nonlinear shift register, and then allocates this address and tell the generator polynomial of this shift register to this new node. By this means, when other node joins this network, any node that has obtained an IP address can act as a server to allocate address to this new node. PRDAC can also efficiently avoid IP conflicts and deal with network partition and merge as same as prophet address (PA) allocation and dynamic configuration and distribution protocol (DCDP). Furthermore, PRDAC has less algorithm complexity, less computational complexity and more sufficient assumption than PA. In addition, PRDAC radically avoids address conflicts and maximizes the utilization rate of IP addresses. Analysis and simulation results show that PRDAC has rapid convergence, low overhead and immune from topological structures.

  11. Protocols for data hiding in pseudo-random state

    Science.gov (United States)

    Craver, Scott; Li, Enping; Yu, Jun

    2009-02-01

    An emerging form of steganographic communication uses ciphertext to replace the output of a random or strong pseudo-random number generator. PRNG-driven media, for example computer animated backdrops in video-conferencing channels, can then be used as a covert channel, if the PRNG bits that generated a piece of content can be estimated by the recipient. However, all bits sent over such a channel must be computationally indistinguishable from i.i.d. coin flips. Ciphertext messages and even key exchange datagrams are easily shaped to match this distribution; however, when placing these messages into a continous stream of PRNG bits, the sender is unable to provide synchronization markers, metadata, or error correction to ensure the message's location and proper decoding. In this paper we explore methods for message transmission and steganographic key exchange in such a "coin flip" channel. We establish that key exchange is generally not possible in this channel if an adversary possesses even a modest noise budget. If the warden is not vigilant in adding noise, however, communication is very simple.

  12. PulseNet International: Vision for the implementation of whole genome sequencing (WGS) for global food-borne disease surveillance.

    Science.gov (United States)

    Nadon, Celine; Van Walle, Ivo; Gerner-Smidt, Peter; Campos, Josefina; Chinen, Isabel; Concepcion-Acevedo, Jeniffer; Gilpin, Brent; Smith, Anthony M; Man Kam, Kai; Perez, Enrique; Trees, Eija; Kubota, Kristy; Takkinen, Johanna; Nielsen, Eva Møller; Carleton, Heather

    2017-06-08

    PulseNet International is a global network dedicated to laboratory-based surveillance for food-borne diseases. The network comprises the national and regional laboratory networks of Africa, Asia Pacific, Canada, Europe, Latin America and the Caribbean, the Middle East, and the United States. The PulseNet International vision is the standardised use of whole genome sequencing (WGS) to identify and subtype food-borne bacterial pathogens worldwide, replacing traditional methods to strengthen preparedness and response, reduce global social and economic disease burden, and save lives. To meet the needs of real-time surveillance, the PulseNet International network will standardise subtyping via WGS using whole genome multilocus sequence typing (wgMLST), which delivers sufficiently high resolution and epidemiological concordance, plus unambiguous nomenclature for the purposes of surveillance. Standardised protocols, validation studies, quality control programmes, database and nomenclature development, and training should support the implementation and decentralisation of WGS. Ideally, WGS data collected for surveillance purposes should be publicly available, in real time where possible, respecting data protection policies. WGS data are suitable for surveillance and outbreak purposes and for answering scientific questions pertaining to source attribution, antimicrobial resistance, transmission patterns, and virulence, which will further enable the protection and improvement of public health with respect to food-borne disease. This article is copyright of The Authors, 2017.

  13. Controlling the Dynamics of Quadrupolar Spin-1 Nuclei by Means of Average Hamiltonian Theory When Irradiated with Modified Composite Quadrupolar Echo Pulse Sequences.

    Science.gov (United States)

    Mananga, Eugene Stephane; Hu, Bingwen

    2016-11-03

    The importance of the average Hamiltonian theory and its antecedent the Magnus expansion are discussed. The investigation of its convergence in different situations is very important. In this paper, we introduced a well-established approach to minimize the zeroth-order average Hamiltonian for modified composite pulse sequence in quadrupolar spectroscopy of spin-1. We designed two modified composite pulse sequences constructed by modifying the timing sequence in the original composite pulse sequences.17 We tested various configurations of times associated with the free evolution of the spin system in the modified composite pulses. We found that by decreasing the time delays between the pulses associated with the free evolution of spin system, the line shapes become increasingly better until we obtained the new modified composite pulses showing improvement of the signal compared to the original composite pulse sequences.17 This promising work is expected to play an important role not only for recording high resolution spectra of amino acids, pharmaceutical samples, and peptides but also for probing structural and dynamic information in biomolecules. The generality of the present theoretical scheme points to potential applications in solid-state NMR, to problems in chemical physics, quantum mechanics and theoretical developments, chemistry, and physical chemistry, and in interdisciplinary research areas whenever they include spin dynamics approach.

  14. Magnetic resonance imaging of the normal pituitary gland using ultrashort TE (UTE) pulse sequences (REV 1.0)

    Energy Technology Data Exchange (ETDEWEB)

    Portman, Olivia; Flemming, Stephen; Cox, Jeremy P.D.; Johnston, Desmond G. [Imperial College Faculty of Medicine, St Mary' s Hospital, Endocrinology and Metabolic Medicine, London (United Kingdom); Bydder, Graeme M. [University of California, San Diego, Department of Radiology, San Diego, CA (United States)

    2008-03-15

    The purpose of this study was to examine the normal pituitary gland in male subjects with ultrashort echo time (TE) pulse sequences, describe its appearance and measure its signal intensity before and after contrast enhancement. Eleven male volunteers (mean age 57.1 years; range 36-81 years) were examined with a fat-suppressed ultrashort TE (= 0.08 ms) pulse sequence. The studies were repeated after the administration of intravenous gadodiamide. The MR scans were examined for gland morphology and signal intensity before and after enhancement. Endocrinological evaluation included baseline pituitary function tests and a glucagon stimulatory test to assess pituitary cortisol and growth hormone reserve. High signal intensity was observed in the anterior pituitary relative to the brain in nine of the 11 subjects. These regions involved the whole of the anterior pituitary in three subjects, were localised to one side in two examples and were seen inferiorly in three subjects. Signal intensities relative to the brain increased with age, with a peak around the sixth or seventh decade and decreasing thereafter. Overall, the pituitary function tests were considered to be within normal limits and did not correlate with pituitary gland signal intensity. The anterior pituitary shows increased signal intensity in normal subjects when examined with T{sub 1}-weighted ultrashort TE pulse sequences. The cause of this increased intensity is unknown, but fibrosis and iron deposition are possible candidates. The variation in signal intensity with age followed the temporal pattern of iron content observed at post mortem. No relationship with endocrine status was observed. (orig.)

  15. Intestinal lesions in pediatric Crohn disease: comparative detectability among pulse sequences at MR enterography

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Beomseok; Kim, Myung-Joon; Lee, Mi-Jung [Severance Children' s Hospital, Yonsei University, College of Medicine, Department of Radiology and Research Institute of Radiological Science, Seoul (Korea, Republic of); Koh, Hong [Severance Children' s Hospital, Department of Pediatrics, Seoul (Korea, Republic of); Han, Kyung Hwa [Yonsei University, College of Medicine, Biostatistics Collaboration Unit, Seoul (Korea, Republic of)

    2014-07-15

    Variable sequences can be used in MR enterography, and no consensus exists for the best protocol in children with Crohn disease. To compare the lesion detectability of various MR enterography sequences and to correlate the findings of these sequences with the Pediatric Crohn's Disease Activity Index (PCDAI) in children with Crohn disease. Children with clinically or pathologically confirmed Crohn disease underwent MR enterography, including a single-shot fast spin-echo (SSFSE) sequence, motility imaging (coronal 2-D balanced fast field echo), diffusion-weighted imaging (DWI), and dynamic contrast enhancement imaging (including arterial, portal and delayed phases). The lesion detectability of each sequence was graded 0-2 for each involved bowel segment. The lesion detectability and PCDAI result on different sequences were compared using the weighted least squares method and Student's t-test, respectively. Fifteen children (11 boys, 4 girls, mean age 13.7 ± 1.4 years) with a total of 41 lesions were included in this study. All lesions detected in more than two sequences were visible on the single-shot fast spin-echo (SSFSE) sequence. The relative lesion detection rate was 78.1% on motility imaging, 90.2% on DWI, and 92.7% on arterial, 95.1% on portal and 95.1% on delayed phase imaging. Compared to the SSFSE sequence, motility imaging (P < 0.001) and DWI (P = 0.039) demonstrated lower detectability. The mean PCDAI result in the detected lesions was statistically higher only on dynamic enhancement imaging (P < 0.001). All MR enterography sequences were found to have relatively high lesion detectability in children with Crohn disease, while motility imaging showed the lowest lesion detectability. Lesions detected on dynamic enhancement imaging showed a higher PCDAI result, which suggests that this sequence is specific for active inflammation. (orig.)

  16. Intestinal lesions in pediatric Crohn disease: comparative detectability among pulse sequences at MR enterography.

    Science.gov (United States)

    Sohn, Beomseok; Kim, Myung-Joon; Koh, Hong; Han, Kyung Hwa; Lee, Mi-Jung

    2014-07-01

    Variable sequences can be used in MR enterography, and no consensus exists for the best protocol in children with Crohn disease. To compare the lesion detectability of various MR enterography sequences and to correlate the findings of these sequences with the Pediatric Crohn's Disease Activity Index (PCDAI) in children with Crohn disease. Children with clinically or pathologically confirmed Crohn disease underwent MR enterography, including a single-shot fast spin-echo (SSFSE) sequence, motility imaging (coronal 2-D balanced fast field echo), diffusion-weighted imaging (DWI), and dynamic contrast enhancement imaging (including arterial, portal and delayed phases). The lesion detectability of each sequence was graded 0-2 for each involved bowel segment. The lesion detectability and PCDAI result on different sequences were compared using the weighted least squares method and Student's t-test, respectively. Fifteen children (11 boys, 4 girls, mean age 13.7 ± 1.4 years) with a total of 41 lesions were included in this study. All lesions detected in more than two sequences were visible on the single-shot fast spin-echo (SSFSE) sequence. The relative lesion detection rate was 78.1% on motility imaging, 90.2% on DWI, and 92.7% on arterial, 95.1% on portal and 95.1% on delayed phase imaging. Compared to the SSFSE sequence, motility imaging (P Crohn disease, while motility imaging showed the lowest lesion detectability. Lesions detected on dynamic enhancement imaging showed a higher PCDAI result, which suggests that this sequence is specific for active inflammation.

  17. HV discharge acceleration by sequences of UV laser filaments with visible and near-infrared pulses

    Science.gov (United States)

    Schubert, Elise; Rastegari, Ali; Feng, Chengyong; Mongin, Denis; Kamer, Brian; Kasparian, Jérôme; Wolf, Jean-Pierre; Arissian, Ladan; Diels, Jean-Claude

    2017-12-01

    We investigate the triggering and guiding of DC high-voltage discharges over a distance of 37 cm by filaments produced by ultraviolet (266 nm) laser pulses of 200 ps duration. The latter reduce the breakdown electric field by half and allow up to 80% discharge probability in an electric field of 920 kV m–1. This high efficiency is not further increased by adding nanosecond pulses in the Joule range at 532 and at 1064 nm. However, the latter statistically increases the guiding length, thereby accelerating the discharge by a factor of 2. This effect is due both to photodetachment and to the heating of the plasma channel, that increases the efficiency of avalanche ionization and reduces electron attachment and recombination.

  18. Exploiting ecology in drug pulse sequences in favour of population reduction.

    Science.gov (United States)

    Bauer, Marianne; Graf, Isabella R; Ngampruetikorn, Vudtiwat; Stephens, Greg J; Frey, Erwin

    2017-09-01

    A deterministic population dynamics model involving birth and death for a two-species system, comprising a wild-type and more resistant species competing via logistic growth, is subjected to two distinct stress environments designed to mimic those that would typically be induced by temporal variation in the concentration of a drug (antibiotic or chemotherapeutic) as it permeates through the population and is progressively degraded. Different treatment regimes, involving single or periodical doses, are evaluated in terms of the minimal population size (a measure of the extinction probability), and the population composition (a measure of the selection pressure for resistance or tolerance during the treatment). We show that there exist timescales over which the low-stress regime is as effective as the high-stress regime, due to the competition between the two species. For multiple periodic treatments, competition can ensure that the minimal population size is attained during the first pulse when the high-stress regime is short, which implies that a single short pulse can be more effective than a more protracted regime. Our results suggest that when the duration of the high-stress environment is restricted, a treatment with one or multiple shorter pulses can produce better outcomes than a single long treatment. If ecological competition is to be exploited for treatments, it is crucial to determine these timescales, and estimate for the minimal population threshold that suffices for extinction. These parameters can be quantified by experiment.

  19. Optimization of parameter values for complex pulse sequences by simulated annealing: application to 3D MP-RAGE imaging of the brain.

    Science.gov (United States)

    Epstein, F H; Mugler, J P; Brookeman, J R

    1994-02-01

    A number of pulse sequence techniques, including magnetization-prepared gradient echo (MP-GRE), segmented GRE, and hybrid RARE, employ a relatively large number of variable pulse sequence parameters and acquire the image data during a transient signal evolution. These sequences have recently been proposed and/or used for clinical applications in the brain, spine, liver, and coronary arteries. Thus, the need for a method of deriving optimal pulse sequence parameter values for this class of sequences now exists. Due to the complexity of these sequences, conventional optimization approaches, such as applying differential calculus to signal difference equations, are inadequate. We have developed a general framework for adapting the simulated annealing algorithm to pulse sequence parameter value optimization, and applied this framework to the specific case of optimizing the white matter-gray matter signal difference for a T1-weighted variable flip angle 3D MP-RAGE sequence. Using our algorithm, the values of 35 sequence parameters, including the magnetization-preparation RF pulse flip angle and delay time, 32 flip angles in the variable flip angle gradient-echo acquisition sequence, and the magnetization recovery time, were derived. Optimized 3D MP-RAGE achieved up to a 130% increase in white matter-gray matter signal difference compared with optimized 3D RF-spoiled FLASH with the same total acquisition time. The simulated annealing approach was effective at deriving optimal parameter values for a specific 3D MP-RAGE imaging objective, and may be useful for other imaging objectives and sequences in this general class.

  20. Distribution of periodic trajectories of C-K systems MIXMAX pseudorandom number generator

    Science.gov (United States)

    Görlich, Andrzej; Kalomenopoulos, Marios; Savvidy, Konstantin; Savvidy, George

    We are considering the hyperbolic C-K systems of Anosov-Kolmogorov which are defined on high dimensional tori and are used to generate pseudorandom numbers for Monte-Carlo simulations. All trajectories of the C-K systems are exponentially unstable and pseudorandom numbers are represented in terms of coordinates of very long chaotic trajectories. The C-K systems on a torus have countable set of everywhere dense periodic trajectories and their distribution play a crucial role in coding and implementation of the pseudorandom number generator. The asymptotic distribution of chaotic trajectories of C-K systems with periods less than a given number is well known in mathematical literature, but a deviation from its asymptotic behavior is unknown. Using analytical and computer calculations, we are studying a distribution function of periodic trajectories and their deviation from asymptotic behavior. The corresponding MIXMAX generator has the best combination of speed, size of the state and is currently available generator.

  1. Synchronizing microelectrode and electronic goniometer data using a pseudo-random binary signal.

    Science.gov (United States)

    Moore, Tyler Robert; Jacobs, Rennie Underwood; Yang, Alexander Cheung; Richter, Erich Oscar

    2013-04-01

    Intra-operative investigation of the subthalamic nucleus (STN) requires concurrent measurement of microelectrode voltage, electrode depth and joint movement during deep brain stimulation (DBS) surgery. Commercial solutions to this problem exist but are more expensive. Multiple instruments from different manufacturers can collect the same data, but data from incompatible instruments are collected on disparate clocks, precluding quantitative analysis. A pseudo-random binary signal recorded simultaneously by each set of instruments allows for chronological reconciliation. A custom program collects microelectrode data while simultaneously sending a pseudo-random binary signal to instruments measuring joint movement. The record of this signal is later used to express microelectrode voltage and joint position in a single chronological frame of reference. ClockSynch was used in 15 DBS procedures. After each surgery, records of microelectrode and joint movement were successfully chronologically reconciled. In conclusion, a pseudo-random binary signal integrates disparate systems of instrumentation at a significantly decreased cost.

  2. Non-periodic pseudo-random numbers used in Monte Carlo calculations

    Science.gov (United States)

    Barberis, Gaston E.

    2007-09-01

    The generation of pseudo-random numbers is one of the interesting problems in Monte Carlo simulations, mostly because the common computer generators produce periodic numbers. We used simple pseudo-random numbers generated with the simplest chaotic system, the logistic map, with excellent results. The numbers generated in this way are non-periodic, which we demonstrated for 1013 numbers, and they are obtained in a deterministic way, which allows to repeat systematically any calculation. The Monte Carlo calculations are the ideal field to apply these numbers, and we did it for simple and more elaborated cases. Chemistry and Information Technology use this kind of simulations, and the application of this numbers to quantum Monte Carlo and cryptography is immediate. I present here the techniques to calculate, analyze and use these pseudo-random numbers, show that they lack periodicity up to 1013 numbers and that they are not correlated.

  3. Zero sequence blocking transformers for multi-pulse rectifier in aerospace applications

    DEFF Research Database (Denmark)

    Yao, Wenli; Blaabjerg, Frede; Zhang, Xiaobin

    2014-01-01

    The power electronics technology plays an even more important role in the aerospace applications of More Electric Aircrafts (MEA). AutoTransformer Rectifier Units (ATRU) have been widely adopted in aircrafts due to its simplicity and reliability. In this paper, Zero Sequence Blocking Transformers...

  4. MR arthrography of the shoulder: Optimizing pulse sequence protocols for the evaluation of cartilage and labrum

    Energy Technology Data Exchange (ETDEWEB)

    Guermazi, Ali, E-mail: Ali.Guermazi@aspetar.com [ASPETAR – Qatar Orthopaedic and Sports Medicine Hospital, Sport City Street, Near Khalifa Stadium, P.O. Box 29222 (Qatar); Department of Radiology, Boston University School of Medicine, 820 Harrison Avenue, FGH Building, 3rd Floor, Boston, MA 02118 (United States); Jomaah, Nabil [ASPETAR – Qatar Orthopaedic and Sports Medicine Hospital, Sport City Street, Near Khalifa Stadium, P.O. Box 29222 (Qatar); Hayashi, Daichi [ASPETAR – Qatar Orthopaedic and Sports Medicine Hospital, Sport City Street, Near Khalifa Stadium, P.O. Box 29222 (Qatar); Department of Radiology, Boston University School of Medicine, 820 Harrison Avenue, FGH Building, 3rd Floor, Boston, MA 02118 (United States); Department of Radiology, Bridgeport Hospital, Yale University School of Medicine, 267 Grant Street, Bridgeport, CT 06610 (United States); Jarraya, Mohamed [ASPETAR – Qatar Orthopaedic and Sports Medicine Hospital, Sport City Street, Near Khalifa Stadium, P.O. Box 29222 (Qatar); Department of Radiology, Boston University School of Medicine, 820 Harrison Avenue, FGH Building, 3rd Floor, Boston, MA 02118 (United States); Silva, Jose Roberto [Department of Radiology, Boston University School of Medicine, 820 Harrison Avenue, FGH Building, 3rd Floor, Boston, MA 02118 (United States); Niu, Jingbo [Clinical Epidemiology Research and Training Unit, Boston University School of Medicine, 650 Albany Street, Suite 200, Boston, MA 02118 (United States); Almusa, Emad; Landreau, Philippe [ASPETAR – Qatar Orthopaedic and Sports Medicine Hospital, Sport City Street, Near Khalifa Stadium, P.O. Box 29222 (Qatar); and others

    2014-08-15

    Objectives: To compare axial T1weighted fat-saturated (T1w fs) and T1w non-fs sequences, and coronal T1w-fs and T2w-fs sequences, for evaluation of cartilage and labrum using CT arthrography (CTA) as the reference. Methods: Patients had MR arthrography (MRA) and CTA of the shoulder on the same day. Cartilage was assessed for superficial and full thickness focal and diffuse damage. Labral lesions were graded for Bankart variants and SLAP lesions. CTA images were read for the same features. The diagnostic performance of MRA including area under the curve (AUC) was evaluated against CTA. Results: When comparing axial sequences, the diagnostic performance for cartilage lesion detection on T1w non-fs was 61.9% (sensitivity) 93.6% (specificity) and 89.5% (accuracy) with AUC 0.782, while that for T1w fs was 61.9%, 94.0%, 89.8% and 0.783. For labral assessment, it was 89.1%, 93.0%, 91.4% and 0.919 for T1w non-fs, and 89.9%, 94.0%, 92.6% and 0.922 for T1w fs. Comparing coronal sequences, diagnostic performance for cartilage was 42.5%, 97.5%, 89.8% and 0.702 for T1w fs, and 38.4%, 98.7%, 90.2%, and 0.686 for T2w fs. For the labrum it was 85.1%, 87.5%, 86.2%, and 0.868 for T1w fs, and 75.7%, 97.5%, 80.8% and 0.816 for T2w fs. Conclusions: Axial T1w fs and T1w non-fs sequences are comparable in their ability to diagnose cartilage and labral lesions. Coronal T1w fs sequence offers slightly higher sensitivity but slightly lower specificity than T2w fs sequence for diagnosis of cartilage and labral lesions.

  5. Wideband arrhythmia-Insensitive-rapid (AIR) pulse sequence for cardiac T1 mapping without image artifacts induced by an implantable-cardioverter-defibrillator.

    Science.gov (United States)

    Hong, KyungPyo; Jeong, Eun-Kee; Wall, T Scott; Drakos, Stavros G; Kim, Daniel

    2015-08-01

    To develop and evaluate a wideband arrhythmia-insensitive-rapid (AIR) pulse sequence for cardiac T1 mapping without image artifacts induced by implantable-cardioverter-defibrillator (ICD). We developed a wideband AIR pulse sequence by incorporating a saturation pulse with wide frequency bandwidth (8.9 kHz) to achieve uniform T1 weighting in the heart with ICD. We tested the performance of original and "wideband" AIR cardiac T1 mapping pulse sequences in phantom and human experiments at 1.5 Tesla. In five phantoms representing native myocardium and blood and postcontrast blood/tissue T1 values, compared with the control T1 values measured with an inversion-recovery pulse sequence without ICD, T1 values measured with original AIR with ICD were considerably lower (absolute percent error > 29%), whereas T1 values measured with wideband AIR with ICD were similar (absolute percent error T1 values measured with original AIR without ICD, T1 measured with original AIR with ICD was significantly lower (absolute percent error > 10.1%), whereas T1 measured with wideband AIR with ICD was similar (absolute percent error T1 mapping without significant image artifacts induced by ICD. © 2015 Wiley Periodicals, Inc.

  6. A note on the multiple-recursive matrix method for generating pseudorandom vectors

    OpenAIRE

    Bishoi, Susil Kumar; Haran, Himanshu Kumar; Hasan, Sartaj Ul

    2016-01-01

    The multiple-recursive matrix method for generating pseudorandom vectors was introduced by Niederreiter (Linear Algebra Appl. 192 (1993), 301-328). We propose an algorithm for finding an efficient primitive multiple-recursive matrix method. Moreover, for improving the linear complexity, we introduce a tweak on the contents of the primitive multiple-recursive matrix method.

  7. Pseudo-Random Number Generators for Vector Processors and Multicore Processors

    DEFF Research Database (Denmark)

    Fog, Agner

    2015-01-01

    Large scale Monte Carlo applications need a good pseudo-random number generator capable of utilizing both the vector processing capabilities and multiprocessing capabilities of modern computers in order to get the maximum performance. The requirements for such a generator are discussed. New ways ...

  8. From Pseudorandom Walk to Pseudo-Brownian Motion: First Exit Time from a One-Sided or a Two-Sided Interval

    Directory of Open Access Journals (Sweden)

    Aimé Lachal

    2014-01-01

    Full Text Available Let N be a positive integer, c a positive constant and (ξnn≥1 be a sequence of independent identically distributed pseudorandom variables. We assume that the ξn’s take their values in the discrete set {-N,-N+1,…,N-1,N} and that their common pseudodistribution is characterized by the (positive or negative real numbers ℙ{ξn=k}=δk0+(-1k-1c(2Nk+N for any k∈{-N,-N+1,…,N-1,N}. Let us finally introduce (Snn≥0 the associated pseudorandom walk defined on ℤ by S0=0 and Sn=∑j=1n‍ξj for n≥1. In this paper, we exhibit some properties of (Snn≥0. In particular, we explicitly determine the pseudodistribution of the first overshooting time of a given threshold for (Snn≥0 as well as that of the first exit time from a bounded interval. Next, with an appropriate normalization, we pass from the pseudorandom walk to the pseudo-Brownian motion driven by the high-order heat-type equation ∂/∂t=(-1N-1c∂2N/∂x2N. We retrieve the corresponding pseudodistribution of the first overshooting time of a threshold for the pseudo-Brownian motion (Lachal, 2007. In the same way, we get the pseudodistribution of the first exit time from a bounded interval for the pseudo-Brownian motion which is a new result for this pseudoprocess.

  9. [Multilocus sequence typing and pulsed-field gel electrophoresis analysis of Salmonella Paratyphi A isolates from 2000 to 2008, China].

    Science.gov (United States)

    Han, Hui; Zhou, Hai-jian; Cui, Zhi-gang; DU, Peng-cheng; Kan, Biao

    2010-09-01

    To analyze molecular and evolution characteristics of Salmonella Paratyphi A isolates from 2000 to 2008, China. Using pulsed-field gel electrophoresis (PFGE) method with SpeI restriction enzyme, and multilocus sequence typing (MLST) method based on housekeeping genes (aroC, thrA, hisD, purE, sucA, dnaN, hemD, adk, and purA), the genomic variations of 118 Salmonella Paratyphi A isolates from 10 regions during 2000 to 2008 were analyzed. Using PFGE method, 118 Salmonella Paratyphi A isolates were clustered into 32 PFGE patterns, and 5 patterns were predominant (5 isolates or above). However, only 2 MLST types were identified for all isolates with MLST method. Among all Salmonella Paratyphi A isolates, the sequences of housekeeping genes were highly conservative and showed a high degree of cloning. For Chinese epidemic Salmonella Paratyphi A isolates during 2000 - 2008, MLST method showed low discrimination power and the MLST method should not be applied to outbreak and epidemiological surveillance of Salmonella Paratyphi A. Currently, nationwide paratyphoid fever epidemics is caused by highly clonal isolates in China. As the time changes, these isolates also accumulate sporadic mutations.

  10. The autocorrelation structure of Tausworthe pseudorandom number generators

    Science.gov (United States)

    Neuman, F.; Martin, C. F.

    1976-01-01

    An algorithm for determining the autocorrelation structure of a new sequence generated from an original sequence by proper decimation (a shift with each q-th term of the original sequence used) is presented, once autocorrelations for any repeating number sequence are known. The autocorrelation structure of the Tausworthe random number generator (RNG), based on proper decimation by q, is accepted as a RNG structure in which a proper decimation generates a long interval over which autocorrelations are small for all shifts. It is shown that if L bits of an N-bit Tausworthe RNG are L-bit binary numbers, L + 1 levels of correlation will exist, and L levels of correlation will each occur twice per RNG cycle length.

  11. hnCOcaNH and hncoCANH pulse sequences for rapid and unambiguous backbone assignment in (13C, 15N) labeled proteins.

    Science.gov (United States)

    Kumar, Dinesh; Reddy, Jithender G; Hosur, Ramakrishna V

    2010-09-01

    Time-saving in data acquisition is a major thrust of NMR pulse sequence development in the context of structural proteomics research. The conventional HNCA and HN(CA)CO pulse sequences, routinely used for sequential backbone assignment, have the limitation that they cannot distinguish inter- and intra-residue correlations. In order to remove this ambiguity, one has to record HNCO and HN(CO)CA or sequential HNCA experiments which provide unambiguous information of sequential correlations. However, this almost doubles the experimental time. Besides, they require repeated scanning through the (15)N planes to search for the matching peaks along the carbon dimension. In this background, we present here two pulse sequences, termed as hncoCANH and hnCOcaNH that lead to spectra equivalent to HNCA and HN(CA)CO spectra, respectively, but with direct distinction of inter- and intra-residue peaks; these occur with opposite signs in the new experiments. The two pulse sequences have been derived by simple modification of the previously described HN(C)N pulse sequence [Panchal et al., J. Biomol. NMR 20 (2001) 135-147] to frequency-label (13)C(alpha) or (13)C' instead of (15)N during the t(1) period. Like HN(C)N, these spectra also exhibit special patterns of self and sequential peaks around glycines and prolines, which enable direct identification of certain triplets of residues and thus provide internal checks during the sequential assignment walk. The spectra enable rapid and unambiguous assignment of H(N), (15)N and (13)C(alpha) (or (13)C') in a single experiment, and thus would be of great value in high-throughput structural proteomics. (c) 2010. Published by Elsevier Inc.

  12. Calibration of Modulation Transfer Function of Surface Profilometers with 1D and 2D Binary Pseudo-random Array Standards

    Energy Technology Data Exchange (ETDEWEB)

    Yashchuk, Valeriy V.; McKinney, Wayne R.; Takacs, Peter Z.

    2008-05-19

    We suggest and describe the use of a binary pseudo-random grating as a standard test surface for calibration of the modulation transfer function of microscopes. Results from calibration of a MicromapTM-570 interferometric microscope are presented.

  13. Multiprime Blum-Blum-Shub Pseudorandom Number Generator

    Science.gov (United States)

    2016-09-01

    time pad). For example, suppose our message is M = 1100110. In order to encrypt it, we add a string of random bits, B = 1011010 and Exclusive-Or ( XOR ...GHz Intel Core i5 • Memory: 4 GB 1600 MHz DDR3 • Graphics : Intel HD Graphics 6000 1536 MB We record the time taken to generate 200 sequences for the...Here, the tests are designed to test a null hypothesis H0, which is the hypothesis that the sequences are random. Along with the null hypothesis, the

  14. Comparison of multilocus sequence typing and pulsed-field gel electrophoresis for Salmonella spp. identification in surface water

    Science.gov (United States)

    Kuo, Chun Wei; Hao Huang, Kuan; Hsu, Bing Mu; Tsai, Hsien Lung; Tseng, Shao Feng; Kao, Po Min; Shen, Shu Min; Chou Chiu, Yi; Chen, Jung Sheng

    2013-04-01

    Salmonella is one of the most important pathogens of waterborne diseases with outbreaks from contaminated water reported worldwide. In addition, Salmonella spp. can survive for long periods in aquatic environments. To realize genotypes and serovars of Salmonella in aquatic environments, we isolated the Salmonella strains by selective culture plates to identify the serovars of Salmonella by serological assay, and identify the genotypes by Multilocus sequence typing (MLST) based on the sequence data from University College Cork (UCC), respectively. The results show that 36 stream water samples (30.1%) and 18 drinking water samples (23.3%) were confirmed the existence of Salmonella using culture method combined PCR specific invA gene amplification. In this study, 24 cultured isolates of Salmonella from water samples were classified to fifteen Salmonella enterica serovars. In addition, we construct phylogenetic analysis using phylogenetic tree and Minimum spanning tree (MST) method to analyze the relationship of clinical, environmental, and geographical data. Phylogenetic tree showed that four main clusters and our strains can be distributed in all. The genotypes of isolates from stream water are more biodiversity while comparing the Salmonella strains genotypes from drinking water sources. According to MST data, we can found the positive correlation between serovars and genotypes of Salmonella. Previous studies revealed that the result of Pulsed field gel electrophoresis (PFGE) method can predict the serovars of Salmonella strain. Hence, we used the MLST data combined phylogenetic analysis to identify the serovars of Salmonella strain and achieved effectiveness. While using the geographical data combined phylogenetic analysis, the result showed that the dominant strains were existed in whole stream area in rainy season. Keywords: Salmonella spp., MLST, phylogenetic analysis, PFGE

  15. An efficient parallel pseudorandom bit generator based on an ...

    Indian Academy of Sciences (India)

    complicated floating-point computation and multiplication computation transform into simple shift bit operations are adopted, that not only ensures the nonlinear operations, but also increases the performance efficiency. The PRBG is implemented in software and hardware. The parallel output bit sequences pass all of the ...

  16. Assessment of the evaluation of liver T1 mapping imaging applying virtual ECG gating on a modified look-locker inversion recovery (MOLLI) pulse sequence

    Science.gov (United States)

    Yu, Seung-Man; Goo, Eun-Hoe; Lee, Suk-Jun; Choe, Bo-Young

    2014-10-01

    A T1 mapping calculation error may occur in a physicochemical environment with large relaxivity. We evaluated through a simulated electrocardiogram (ECG) the administration of a contrast with high relaxivity and its effect on the heart rate by using a modified Look-Locker inversion recovery (MOLLI) pulse sequence. The agarose 2% phantom of high relaxivity environment was developed by diluting gadoxetic acid magnetic resonance imaging (MRI) T1 contrast media. The gold standard T1 determination was based on coronal single section imaging with a 2D inversion-recovery turbo spin echo sequence (2D-IRTSE) in a 3T MR unit. Using the identical 3T MR scanner, we acquired T1 mapping for the MOLLI pulse sequence with various virtual heart rates. T1 mapping data of the two different pulse sequences ( i.e., 2D-IRTSE and MOLLI) were measured to investigate the accuracy and the specificity. An in vivo study was conducted in the same manner as the phantom experiments for liver T1 mapping imaging in three healthy volunteers. The MOLLI pulse sequence showed an error rate of less than 10% at a contrast agent concentration of 0.4 mmol/L, and significant error, compared with the reference value, was observed at 0.6 mmol/L or higher. The percentage error of the T1 value did not correlated with the RR ( i.e., the time between heart beats) change that was observed (P =.270). Based on the in-vivo liver test, T1 mapping imaging of an abdominal organ as the liver can be successfully achieved using the applied virtual ECG gating on the MOLLI sequence.

  17. Cryptographic applications of analytic number theory complexity lower bounds and pseudorandomness

    CERN Document Server

    2003-01-01

    The book introduces new ways of using analytic number theory in cryptography and related areas, such as complexity theory and pseudorandom number generation. Key topics and features: - various lower bounds on the complexity of some number theoretic and cryptographic problems, associated with classical schemes such as RSA, Diffie-Hellman, DSA as well as with relatively new schemes like XTR and NTRU - a series of very recent results about certain important characteristics (period, distribution, linear complexity) of several commonly used pseudorandom number generators, such as the RSA generator, Blum-Blum-Shub generator, Naor-Reingold generator, inversive generator, and others - one of the principal tools is bounds of exponential sums, which are combined with other number theoretic methods such as lattice reduction and sieving - a number of open problems of different level of difficulty and proposals for further research - an extensive and up-to-date bibliography Cryptographers and number theorists will find th...

  18. Cognitive Architecture for Direction of Attention Founded on Subliminal Memory Searches, Pseudorandom and Nonstop

    OpenAIRE

    Burger, J.R.

    2008-01-01

    By way of explaining how a brain works logically, human associative memory is modeled with logical and memory neurons, corresponding to standard digital circuits. The resulting cognitive architecture incorporates basic psychological elements such as short term and long term memory. Novel to the architecture are memory searches using cues chosen pseudorandomly from short term memory. Recalls alternated with sensory images, many tens per second, are analyzed subliminally as an ongoing process, ...

  19. Mersenne Twister: A 623-Dimensionally Equidistributed Uniform Pseudo-Random Number Generator

    OpenAIRE

    Matsumoto, Makoto; Nishimura, Takuji

    1998-01-01

    A new algorithm called Mersenne Twister (MT) is proposed for generating uniform pseudorandom numbers. For a particular choice of parameters, the algorithm provides a super astronomical period of 219937 - 1 and 623-dimensional equidistribution up to 32-bit accuracy, while using a working area of only 624 words. This is a new variant of the previously proposed generators, TGFSR, modified so as to admit a Mersenne-prime period. The characteristic polynomial has many terms. The distribution up to...

  20. Characterization of Electron Microscopes with Binary Pseudo-random Multilayer Test Samples

    Energy Technology Data Exchange (ETDEWEB)

    V Yashchuk; R Conley; E Anderson; S Barber; N Bouet; W McKinney; P Takacs; D Voronov

    2011-12-31

    Verification of the reliability of metrology data from high quality X-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays has been suggested [1] and [2] and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer [5]. Here we describe the details of development of binary pseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi2/Si multilayer coating with pseudo-randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize X-ray microscopes. Corresponding work with X-ray microscopes is in progress.

  1. Characterization of electron microscopes with binary pseudo-random multilayer test samples

    Energy Technology Data Exchange (ETDEWEB)

    Yashchuk, Valeriy V., E-mail: VVYashchuk@lbl.gov [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Conley, Raymond [NSLS-II, Brookhaven National Laboratory, Upton, NY 11973 (United States); Anderson, Erik H. [Center for X-ray Optics, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Barber, Samuel K. [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Bouet, Nathalie [NSLS-II, Brookhaven National Laboratory, Upton, NY 11973 (United States); McKinney, Wayne R. [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Takacs, Peter Z. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Voronov, Dmitriy L. [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)

    2011-09-01

    Verification of the reliability of metrology data from high quality X-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays has been suggested and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer [5]. Here we describe the details of development of binary pseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi{sub 2}/Si multilayer coating with pseudo-randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize X-ray microscopes. Corresponding work with X-ray microscopes is in progress.

  2. Increased signal intensity on fat-suppressed three-dimensional T1-weighted pulse sequences in patellar tendon: magic angle effect?

    Energy Technology Data Exchange (ETDEWEB)

    Karantanas, A.H.; Zibis, A.H. [CT-MRI Dept., Larissa General Hospital, Larissa (Greece); Papanikolaou, N. [Radiology Dept., University of Crete, Heraklion (Greece)

    2001-02-01

    Objective. To assess the frequency of increased signal intensity in the patellar tendon using three-dimensional T1-weighted MRI pulse sequences. Design and patients. Sixty patients were examined with a 1.0 T scanner (15mT/m gradient strength) using a quadrature coil. Three pulse sequences were applied in the sagittal plane: PD turbo spin echo (PD-TSE), 3D T1-weighted gradient echo with fat suppression (3D-T1-FFE-FS) and 3D T1-weighted echo planar imaging with fat suppression (3D-T1-EPI-FS). The high signal intensity areas were measured in their maximum length. The angle of the patellar tendon relative to the main field position was measured in the same slice. In eight patients with anterior knee pain, and in 11 with no anterior knee pain, a fourth T2-weighted TSE pulse sequence (T2-TSE) was obtained to rule out patellar tendinitis. Results. The correlation of the high signal intensity areas with the relative position of the tendon was found to be significant with the 3D sequences (P=0.03 for 3D-T1-FFE-FS and P=0.003 for 3D-T1-EPI-FS). The length of the high signal intensity area in the tendon was 5.4 mm with 3D-T1-FFE-FS, 4.9 mm with 3D-T1-EPI-FS and 3.1 mm with PD-TSE images. No patellar tendinitis was demonstrated on the T2-TSE images. Conclusion. The magic angle effect is commonly observed in the 3D based T1-weighted pulse sequences with fat suppression. The presence of the above sign must be recognized by radiologists, so that misdiagnosis of patellar tendinitis is avoided. (orig.)

  3. Flip angle optimization for dynamic contrast-enhanced MRI-studies with spoiled gradient echo pulse sequences

    Science.gov (United States)

    De Naeyer, D.; Verhulst, J.; Ceelen, W.; Segers, P.; De Deene, Y.; Verdonck, P.

    2011-08-01

    Spoiled gradient echo pulse (SPGRE) sequences are commonly used in dynamic contrast-enhanced MRI (DCE-MRI) studies to measure the contrast agent concentration in a tissue of interest over time. However, due to improper tuning of the SPGRE parameters, concentration uncertainty can be very high, even at high signal-to-noise ratio in the MR measurement. In this work, an optimization procedure is proposed for selecting the optimal value of the SPGRE-flip angle FAopt, given the expected concentration range. The optimization condition ensures that every concentration in the assumed range has the lowest possible uncertainty. By decoupling the R1- and R*2-effects caused by the presence of the contrast agent, a contour plot has been generated from which FAopt can be read off for any study design. Investigation of ten recent DCE-MRI studies showed that improper flip angle selection unnecessarily increases the concentration uncertainty, up to 742% and 72% on average for the typical physiological concentration ranges of 0-2 mM in tumour tissue and 0-10 mM in blood, respectively. Simulations show that the reduced noise levels on the concentration curves, observed at the optimal flip angle, effectively increase the precision of the kinetic parameters estimates (up to 82% for Ktrans, 82% for νe and 92% for νp in the case of an individually measured arterial input function (AIF), up to 53% for Ktrans, 59% for νe and 67% for νp in the case of a standard AIF). In vivo experiments confirm the potential of flip angle optimization to increase the reproducibility of the kinetic parameter estimates.

  4. Optimal pseudorandom sequence selection for online c-VEP based BCI control applications

    DEFF Research Database (Denmark)

    Isaksen, Jonas L.; Mohebbi, Ali; Puthusserypady, Sadasivan

    2017-01-01

    wheelchair control task and completed the same task using stimuli based on the m-code, the gold-code, and the Barker-code. Correct/incorrect identification and time consumption were obtained for each identification. Subject-specific templates were characterized and used in a forward-step first-order model...

  5. EPCGen2 pseudorandom number generators: analysis of J3Gen.

    Science.gov (United States)

    Peinado, Alberto; Munilla, Jorge; Fúster-Sabater, Amparo

    2014-04-09

    This paper analyzes the cryptographic security of J3Gen, a promising pseudo random number generator for low-cost passive Radio Frequency Identification (RFID) tags. Although J3Gen has been shown to fulfill the randomness criteria set by the EPCglobal Gen2 standard and is intended for security applications, we describe here two cryptanalytic attacks that question its security claims: (i) a probabilistic attack based on solving linear equation systems; and (ii) a deterministic attack based on the decimation of the output sequence. Numerical results, supported by simulations, show that for the specific recommended values of the configurable parameters, a low number of intercepted output bits are enough to break J3Gen. We then make some recommendations that address these issues.

  6. EPCGen2 Pseudorandom Number Generators: Analysis of J3Gen

    Directory of Open Access Journals (Sweden)

    Alberto Peinado

    2014-04-01

    Full Text Available This paper analyzes the cryptographic security of J3Gen, a promising pseudo random number generator for low-cost passive Radio Frequency Identification (RFID tags. Although J3Gen has been shown to fulfill the randomness criteria set by the EPCglobal Gen2 standard and is intended for security applications, we describe here two cryptanalytic attacks that question its security claims: (i a probabilistic attack based on solving linear equation systems; and (ii a deterministic attack based on the decimation of the output sequence. Numerical results, supported by simulations, show that for the specific recommended values of the configurable parameters, a low number of intercepted output bits are enough to break J3Gen. We then make some recommendations that address these issues.

  7. 1D and 2D diffusion pore imaging on a preclinical MR system using adaptive rephasing: Feasibility and pulse sequence comparison.

    Science.gov (United States)

    Bertleff, Marco; Domsch, Sebastian; Laun, Frederik B; Kuder, Tristan A; Schad, Lothar R

    2017-05-01

    Diffusion pore imaging (DPI) has recently been proposed as a means to acquire images of the average pore shape in an image voxel or region of interest. The highly asymmetric gradient scheme of its sequence makes it substantially demanding in terms of the hardware of the NMR system. The aim of this work is to show the feasibility of DPI on a preclinical 9.4T animal scanner. Using water-filled capillaries with an inner radius of 10μm, four different variants of the DPI sequence were compared in 1D and 2D measurements. The pulse sequences applied cover the basic implementation using one long and one temporally narrow gradient pulse, a CPMG-like variant with multiple refocusing RF pulses as well as two variants splitting up the long gradient and distributing it on either side of the refocusing pulse. Substantial differences between the methods were found in terms of signal-to-noise ratio, contrast, blurring, deviations from the expected results and sensitivity to gradient imperfections. Each of the tested sequences was found to produce characteristic gradient mismatches dependent on the absolute value, direction and sign of the applied q-value. Read gradients were applied to compensate these mismatches translating them into time shifts, which enabled 1D DPI yielding capillary radius estimations within the tolerances specified by the manufacturer. For a successful DPI application in 2D, a novel gradient amplitude adaption scheme was implemented to correct for the occurring time shifts. Using this adaption, higher conformity to the expected pore shape, reduced blurring and enhanced contrast were achieved. Images of the phantom's pore shape could be acquired with a nominal resolution of 2.2μm. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. 1D and 2D diffusion pore imaging on a preclinical MR system using adaptive rephasing: Feasibility and pulse sequence comparison

    Science.gov (United States)

    Bertleff, Marco; Domsch, Sebastian; Laun, Frederik B.; Kuder, Tristan A.; Schad, Lothar R.

    2017-05-01

    Diffusion pore imaging (DPI) has recently been proposed as a means to acquire images of the average pore shape in an image voxel or region of interest. The highly asymmetric gradient scheme of its sequence makes it substantially demanding in terms of the hardware of the NMR system. The aim of this work is to show the feasibility of DPI on a preclinical 9.4 T animal scanner. Using water-filled capillaries with an inner radius of 10 μm, four different variants of the DPI sequence were compared in 1D and 2D measurements. The pulse sequences applied cover the basic implementation using one long and one temporally narrow gradient pulse, a CPMG-like variant with multiple refocusing RF pulses as well as two variants splitting up the long gradient and distributing it on either side of the refocusing pulse. Substantial differences between the methods were found in terms of signal-to-noise ratio, contrast, blurring, deviations from the expected results and sensitivity to gradient imperfections. Each of the tested sequences was found to produce characteristic gradient mismatches dependent on the absolute value, direction and sign of the applied q-value. Read gradients were applied to compensate these mismatches translating them into time shifts, which enabled 1D DPI yielding capillary radius estimations within the tolerances specified by the manufacturer. For a successful DPI application in 2D, a novel gradient amplitude adaption scheme was implemented to correct for the occurring time shifts. Using this adaption, higher conformity to the expected pore shape, reduced blurring and enhanced contrast were achieved. Images of the phantom's pore shape could be acquired with a nominal resolution of 2.2 μm.

  9. The influence of wavelength, temporal sequencing, and pulse duration on resonant infrared matrix-assisted laser processing of polymer films

    Science.gov (United States)

    O'Malley, S. M.; Schoeffling, Jonathan; Jimenez, Richard; Zinderman, Brian; Yi, SunYong; Bubb, D. M.

    2014-06-01

    We have carried out a systematic investigation of laser ablation plume interactions in resonant infrared matrix-assisted pulsed laser evaporation. The laser source utilized in this study was a mid-infrared OPO capable of dual sequential ns pulses with adjustable delay ranging from 1 to 100 μs. This unique capability enabled us both to probe the ablation plume with a second laser pulse, and to effectively double the laser fluence. The primary ablation target used for this study consisted of poly(methyl methacrylate) dissolved in a binary mixture of methanol and toluene. Both the critical thermodynamic and optical properties of the binary mixture were determined and used to interpret our results. We found that deposition rates associated with single pulse irradiation tracks with the optical absorption coefficient in the spectral range from 2,700 to 3,800 nm. In the case of dual sequential pulses, discrepancies in this trend have been linked to the rate of change in the optical absorption coefficient with temperature. The influence of fluence on deposition rate was found to follow a sigmoidal dependence. Surface roughness was observed to have a diametrically opposed trend with pulse delay depending on whether the OH or CH vibrational mode was excited. In the case of CH excitation, we suggest that the rougher films are due to the absorbance of the second pulse by droplets within the plume containing residual solvent which leads to the formation of molecular balloons and hence irregularly shaped features on the substrate.

  10. Signal processing issues for the exploitation of pulse-to-pulse encoding SAR transponders

    DEFF Research Database (Denmark)

    Merryman Boncori, John Peter; Schiavon, Giovanni

    2008-01-01

    -encoding point scatterers and distributed ones. A time-domain processing algorithm and a code synchronization procedure are proposed and validated on simulated data and on a European Remote Sensing Satellite-2 data set containing prototypes of such a device. The interaction of the transponder signal with terrain......Synthetic aperture radar signal processing issues related to the exploitation of a pulse-to-pulse encoding transponder using pseudorandom codes discussed analytically. Namely the focusing algorithm, the code synchronization procedure and the properties of the code induced gain against non...

  11. Pseudo-random Aloha for inter-frame soft combining in RFID systems

    DEFF Research Database (Denmark)

    Castiglione, Paolo; Ricciato, Fabio; Popovski, Petar

    2013-01-01

    In this work we consider a recently proposed variant of the classical Framed Slotted-ALOHA where slot selection is based on a pseudo-random function of the message to be transmitted and of the frame index. We couple this feature with convolutional encoding, that allows to perform Inter-frame Soft...... cancellation (instead of combining). Numerical simulation results show that the ISoC scheme brings a noticeable throughput gain over traditional schemes in a dense RFID scenario with multiple concurrent Tag transmissions....

  12. Pseudo-random tool paths for CNC sub-aperture polishing and other applications.

    Science.gov (United States)

    Dunn, Christina R; Walker, David D

    2008-11-10

    In this paper we first contrast classical and CNC polishing techniques in regard to the repetitiveness of the machine motions. We then present a pseudo-random tool path for use with CNC sub-aperture polishing techniques and report polishing results from equivalent random and raster tool-paths. The random tool-path used - the unicursal random tool-path - employs a random seed to generate a pattern which never crosses itself. Because of this property, this tool-path is directly compatible with dwell time maps for corrective polishing. The tool-path can be used to polish any continuous area of any boundary shape, including surfaces with interior perforations.

  13. Comparison of a quantum random number generator with pseudorandom number generators for their use in molecular Monte Carlo simulations.

    Science.gov (United States)

    Ghersi, Dario; Parakh, Abhishek; Mezei, Mihaly

    2017-12-05

    Four pseudorandom number generators were compared with a physical, quantum-based random number generator using the NIST suite of statistical tests, which only the quantum-based random number generator could successfully pass. We then measured the effect of the five random number generators on various calculated properties in different Markov-chain Monte Carlo simulations. Two types of systems were tested: conformational sampling of a small molecule in aqueous solution and liquid methanol under constant temperature and pressure. The results show that poor quality pseudorandom number generators produce results that deviate significantly from those obtained with the quantum-based random number generator, particularly in the case of the small molecule in aqueous solution setup. In contrast, the widely used Mersenne Twister pseudorandom generator and a 64-bit Linear Congruential Generator with a scrambler produce results that are statistically indistinguishable from those obtained with the quantum-based random number generator. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  14. B1 mapping for bias-correction in quantitative T1 imaging of the brain at 3T using standard pulse sequences.

    Science.gov (United States)

    Boudreau, Mathieu; Tardif, Christine L; Stikov, Nikola; Sled, John G; Lee, Wayne; Pike, G Bruce

    2017-12-01

    B1 mapping is important for many quantitative imaging protocols, particularly those that include whole-brain T1 mapping using the variable flip angle (VFA) technique. However, B1 mapping sequences are not typically available on many magnetic resonance imaging (MRI) scanners. The aim of this work was to demonstrate that B1 mapping implemented using standard scanner product pulse sequences can produce B1 (and VFA T1 ) maps comparable in quality and acquisition time to advanced techniques. Six healthy subjects were scanned at 3.0T. An interleaved multislice spin-echo echo planar imaging double-angle (EPI-DA) B1 mapping protocol, using a standard product pulse sequence, was compared to two alternative methods (actual flip angle imaging, AFI, and Bloch-Siegert shift, BS). Single-slice spin-echo DA B1 maps were used as a reference for comparison (Ref. DA). VFA flip angles were scaled using each B1 map prior to fitting T1 ; the nominal flip angle case was also compared. The pooled-subject voxelwise correlation (ρ) for B1 maps (BS/AFI/EPI-DA) relative to the reference B1 scan (Ref. DA) were ρ = 0.92/0.95/0.98. VFA T1 correlations using these maps were ρ = 0.86/0.88/0.96, much better than without B1 correction (ρ = 0.53). The relative error for each B1 map (BS/AFI/EPI-DA/Nominal) had 95(th) percentiles of 5/4/3/13%. Our findings show that B1 mapping implemented using product pulse sequences can provide excellent quality B1 (and VFA T1 ) maps, comparable to other custom techniques. This fast whole-brain measurement (∼2 min) can serve as an excellent alternative for researchers without access to advanced B1 pulse sequences. 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1673-1682. © 2017 International Society for Magnetic Resonance in Medicine.

  15. Improving the pseudo-randomness properties of chaotic maps using deep-zoom.

    Science.gov (United States)

    Machicao, Jeaneth; Bruno, Odemir M

    2017-05-01

    A generalized method is proposed to compose new orbits from a given chaotic map. The method provides an approach to examine discrete-time chaotic maps in a "deep-zoom" manner by using k-digits to the right from the decimal separator of a given point from the underlying chaotic map. Interesting phenomena have been identified. Rapid randomization was observed, i.e., chaotic patterns tend to become indistinguishable when compared to the original orbits of the underlying chaotic map. Our results were presented using different graphical analyses (i.e., time-evolution, bifurcation diagram, Lyapunov exponent, Poincaré diagram, and frequency distribution). Moreover, taking advantage of this randomization improvement, we propose a Pseudo-Random Number Generator (PRNG) based on the k-logistic map. The pseudo-random qualities of the proposed PRNG passed both tests successfully, i.e., DIEHARD and NIST, and were comparable with other traditional PRNGs such as the Mersenne Twister. The results suggest that simple maps such as the logistic map can be considered as good PRNG methods.

  16. Generalized hardware post-processing technique for chaos-based pseudorandom number generators

    KAUST Repository

    Barakat, Mohamed L.

    2013-06-01

    This paper presents a generalized post-processing technique for enhancing the pseudorandomness of digital chaotic oscillators through a nonlinear XOR-based operation with rotation and feedback. The technique allows full utilization of the chaotic output as pseudorandom number generators and improves throughput without a significant area penalty. Digital design of a third-order chaotic system with maximum function nonlinearity is presented with verified chaotic dynamics. The proposed post-processing technique eliminates statistical degradation in all output bits, thus maximizing throughput compared to other processing techniques. Furthermore, the technique is applied to several fully digital chaotic oscillators with performance surpassing previously reported systems in the literature. The enhancement in the randomness is further examined in a simple image encryption application resulting in a better security performance. The system is verified through experiment on a Xilinx Virtex 4 FPGA with throughput up to 15.44 Gbit/s and logic utilization less than 0.84% for 32-bit implementations. © 2013 ETRI.

  17. Inversion in the steady state: contrast optimization and reduced imaging time with fast three-dimensional inversion-recovery-prepared GRE pulse sequences.

    Science.gov (United States)

    Foo, T K; Sawyer, A M; Faulkner, W H; Mills, D G

    1994-04-01

    To evaluate the differences in contrast between 1-second delay and zero delay (for magnetization recovery) before the preparation radio-frequency pulse in three-dimensional, inversion-recovery (IR) fast gradient-echo (GRE) acquisitions. Mathematical simulations and measurements of brain image contrast were performed with healthy volunteers and 10 patients. The zero-delay sequence generated T1-weighted contrast similar to that obtained with 1-second delay but was accompanied by a substantial reduction in imaging time. However, the zero delay prohibits full recovery of the longitudinal magnetization. Hence, the signal null characteristic of IR experiments is not easily observed, since it occurs (as a function of tissue T1) at very short inversion times (prepared rapid GRE sequences with a 1-second delay and preparation time (TP) of 600-700 msec can be achieved in less time by using a zero delay and a shorter TP (400-500 msec).

  18. Compensation of slice profile mismatch in combined spin- and gradient-echo echo-planar imaging pulse sequences.

    Science.gov (United States)

    Schmiedeskamp, Heiko; Straka, Matus; Bammer, Roland

    2012-02-01

    Combined acquisition of gradient-echo and spin-echo signals in MRI time series reveals additional information for perfusion-weighted imaging and functional MRI because of differences in the sensitivity of gradient-echo and spin-echo measurements to the properties of the underlying vascular architecture. The acquisition of multiple echo trains within one time frame facilitates the simultaneous estimation of the transversal relaxation parameters R2 and R2*. However, the simultaneous estimation of these parameters tends to be incorrect in the presence of slice profile mismatches between signal excitation and subsequent refocusing pulses. It is shown here that improvements in pulse design reduced R2 and R2* estimation errors. Further improvements were achieved by augmented parameter estimation through the introduction of an additional parameter δ to correct for discordances in slice profiles to facilitate more quantitative measurements. Moreover, the analysis of time-resolved acquisitions revealed that the temporal stability of R2 estimates could be increased with improved pulse design, counteracting low contrast-to-noise ratios in spin-echo-based perfusion and functional MRI. Copyright © 2011 Wiley Periodicals, Inc.

  19. Goal-independent mechanisms for free response generation: creative and pseudo-random performance share neural substrates.

    Science.gov (United States)

    de Manzano, Örjan; Ullén, Fredrik

    2012-01-02

    To what extent free response generation in different tasks uses common and task-specific neurocognitive processes has remained unclear. Here, we investigated overlap and differences in neural activity during musical improvisation and pseudo-random response generation. Brain activity was measured using fMRI in a group of professional classical pianists, who performed musical improvisation of melodies, pseudo-random key-presses and a baseline condition (sight-reading), on either two, six or twelve keys on a piano keyboard. The results revealed an extensive overlap in neural activity between the two generative conditions. Active regions included the dorsolateral and dorsomedial prefrontal cortices, inferior frontal gyrus, anterior cingulate cortex and pre-SMA. No regions showed higher activity in improvisation than in pseudo-random generation. These findings suggest that the activated regions fulfill generic functions that are utilized in different types of free generation tasks, independent of overall goal. In contrast, pseudo-random generation was accompanied by higher activity than improvisation in several regions. This presumably reflects the participants' musical expertise as well as the pseudo-random generation task's high load on attention, working memory, and executive control. The results highlight the significance of using naturalistic tasks to study human behavior and cognition. No brain activity was related to the size of the response set. We discuss that this may reflect that the musicians were able to use specific strategies for improvisation, by which there was no simple relationship between response set size and neural activity. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Lung MRI of invasive fungal infection at 3 Tesla: evaluation of five different pulse sequences and comparison with multidetector computed tomography (MDCT)

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Chenggong; Tan, Xiangliang; Li, Caixia; Wu, Yuankui; Hao, Peng; Xiong, Wei; Xu, Yikai [Southern Medical University, Department of Medical Imaging Center, Nanfang Hospital, Guangzhou, Guangdong (China); Wei, Qi; Feng, Ru; Xu, Jun [Southern Medical University, Department of Hematology, Nanfang Hospital, Guangzhou (China); Chan, Queenie [Philips Healthcare, New Territories (China)

    2014-09-18

    To evaluate the diagnostic performance of five MR sequences to detect pulmonary infectious lesions in patients with invasive fungal infection (IFI), using multidetector computed tomography (MDCT) as the reference standard. Thirty-four immunocompromised patients with suspected IFI underwent MDCT and MRI. The MR studies were performed using five pulse sequences at 3.0 T: T2-weighted turbo spin echo (TSE), short-tau inversion recovery (STIR), spectrally selective attenuated inversion recovery (SPAIR), T1-weighted high resolution isotropic volume excitation (e-THRIVE) and T1-weighted fast field echo (T1-FFE). The size, lesion-to-lung contrast ratio and the detectability of pulmonary lesions on MR images were assessed. Image quality and artefacts on different sequences were also rated. A total of 84 lesions including nodules (n = 44) and consolidation (n = 40) were present in 75 lobes. SPAIR and e-THRIVE images achieved high overall lesion-related sensitivities for the detection of pulmonary abnormalities (90.5 % and 86.9 %, respectively). STIR showed the highest lesion-to-lung contrast ratio for nodules (21.8) and consolidation (17.0), whereas TSE had the fewest physiological artefacts. MRI at 3.0 T can depict clinically significant pulmonary IFI abnormalities with high accuracy compared to MDCT. SPAIR and e-THRIVE are preferred sequences for the detection of infectious lesions of 5 mm and larger. (orig.)

  1. Lung Parenchymal Signal Intensity in MRI: A Technical Review with Educational Aspirations Regarding Reversible Versus Irreversible Transverse Relaxation Effects in Common Pulse Sequences.

    Science.gov (United States)

    Mulkern, Robert; Haker, Steven; Mamata, Hatsuho; Lee, Edward; Mitsouras, Dimitrios; Oshio, Koichi; Balasubramanian, Mukund; Hatabu, Hiroto

    2014-03-01

    Lung parenchyma is challenging to image with proton MRI. The large air space results in ~l/5th as many signal-generating protons compared to other organs. Air/tissue magnetic susceptibility differences lead to strong magnetic field gradients throughout the lungs and to broad frequency distributions, much broader than within other organs. Such distributions have been the subject of experimental and theoretical analyses which may reveal aspects of lung microarchitecture useful for diagnosis. Their most immediate relevance to current imaging practice is to cause rapid signal decays, commonly discussed in terms of short T2* values of 1 ms or lower at typical imaging field strengths. Herein we provide a brief review of previous studies describing and interpreting proton lung spectra. We then link these broad frequency distributions to rapid signal decays, though not necessarily the exponential decays generally used to define T2* values. We examine how these decays influence observed signal intensities and spatial mapping features associated with the most prominent torso imaging sequences, including spoiled gradient and spin echo sequences. Effects of imperfect refocusing pulses on the multiple echo signal decays in single shot fast spin echo (SSFSE) sequences and effects of broad frequency distributions on balanced steady state free precession (bSSFP) sequence signal intensities are also provided. The theoretical analyses are based on the concept of explicitly separating the effects of reversible and irreversible transverse relaxation processes, thus providing a somewhat novel and more general framework from which to estimate lung signal intensity behavior in modern imaging practice.

  2. Statistical approach of measurement of signal to noise ratio in according to change pulse sequence on brain MRI meningioma and cyst images

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eul Kyu [Inje Paik University Hospital Jeo-dong, Seoul (Korea, Republic of); Choi, Kwan Woo [Asan Medical Center, Seoul (Korea, Republic of); Jeong, Hoi Woun [The Baekseok Culture University, Cheonan (Korea, Republic of); Jang, Seo Goo [The Soonchunhyang University, Asan (Korea, Republic of); Kim, Ki Won [Kyung Hee University Hospital at Gang-dong, Seoul (Korea, Republic of); Son, Soon Yong [The Wonkwang Health Science University, Iksan (Korea, Republic of); Min, Jung Whan; Son, Jin Hyun [The Shingu University, Sungnam (Korea, Republic of)

    2016-09-15

    The purpose of this study was to needed basis of measure MRI CAD development for signal to noise ratio (SNR) by pulse sequence analysis from region of interest (ROI) in brain magnetic resonance imaging (MRI) contrast. We examined images of brain MRI contrast enhancement of 117 patients, from January 2005 to December 2015 in a University-affiliated hospital, Seoul, Korea. Diagnosed as one of two brain diseases such as meningioma and cysts SNR for each patient's image of brain MRI were calculated by using Image J. Differences of SNR among two brain diseases were tested by SPSS Statistics21 ANOVA test for there was statistical significance (p < 0.05). We have analysis socio-demographical variables, SNR according to sequence disease, 95% confidence according to SNR of sequence and difference in a mean of SNR. Meningioma results, with the quality of distributions in the order of T1CE, T2 and T1, FLAIR. Cysts results, with the quality of distributions in the order of T2 and T1, T1CE and FLAIR. SNR of MRI sequences of the brain would be useful to classify disease. Therefore, this study will contribute to evaluate brain diseases, and be a fundamental to enhancing the accuracy of CAD development.

  3. Study of a New Chaotic Dynamical System and Its Usage in a Novel Pseudorandom Bit Generator

    Directory of Open Access Journals (Sweden)

    Ana-Cristina Dăscălescu

    2013-01-01

    Full Text Available A new chaotic discrete dynamical system, built on trigonometric functions, is proposed. With intent to use this system within cryptographic applications, we proved with the aid of specific tools from chaos theory (e.g., Lyapunov exponent, attractor’s fractal dimension, and Kolmogorov-Smirnov test and statistics (e.g., NIST suite of tests that the newly proposed dynamical system has a chaotic behavior, for a large parameter’s value space, and very good statistical properties, respectively. Further, the proposed chaotic dynamical system is used, in conjunction with a binary operation, in the designing of a new pseudorandom bit generator (PRBG model. The PRBG is subjected, by turns, to an assessment of statistical properties. Theoretical and practical arguments, rounded by good statistical results, confirm viability of the proposed chaotic dynamical system and newly designed PRBG, recommending them for usage within cryptographic applications.

  4. Systolic MOLLI T1 mapping with heart-rate-dependent pulse sequence sampling scheme is feasible in patients with atrial fibrillation.

    Science.gov (United States)

    Zhao, Lei; Li, Songnan; Ma, Xiaohai; Greiser, Andreas; Zhang, Tianjing; An, Jing; Bai, Rong; Dong, Jianzeng; Fan, Zhanming

    2016-03-15

    T1 mapping enables assessment of myocardial characteristics. As the most common type of arrhythmia, atrial fibrillation (AF) is often accompanied by a variety of cardiac pathologies, whereby the irregular and usually rapid ventricle rate of AF may cause inaccurate T1 estimation due to mis-triggering and inadequate magnetization recovery. We hypothesized that systolic T1 mapping with a heart-rate-dependent (HRD) pulse sequence scheme may overcome this issue. 30 patients with AF and 13 healthy volunteers were enrolled and underwent cardiovascular magnetic resonance (CMR) at 3 T. CMR was repeated for 3 patients after electric cardioversion and for 2 volunteers after lowering heart rate (HR). A Modified Look-Locker Inversion Recovery (MOLLI) sequence was acquired before and 15 min after administration of 0.1 mmol/kg gadopentetate dimeglumine. For AF patients, both the fixed 5(3)3/4(1)3(1)2 and the HRD sampling scheme were performed at diastole and systole, respectively. The HRD pulse sequence sampling scheme was 5(n)3/4(n)3(n)2, where n was determined by the heart rate to ensure adequate magnetization recovery. Image quality of T1 maps was assessed. T1 times were measured in myocardium and blood. Extracellular volume fraction (ECV) was calculated. In volunteers with repeated T1 mapping, the myocardial native T1 and ECV generated from the 1st fixed sampling scheme were smaller than from the 1st HRD and 2nd fixed sampling scheme. In healthy volunteers, the overall native T1 times and ECV of the left ventricle (LV) in diastolic T1 maps were greater than in systolic T1 maps (P T1 times and ECV generated from the fixed sampling scheme were smaller than in the 1st and 2nd HRD sampling scheme (all P T1 maps with artifact were found in diastole than in systole (P T1 times and ECV of the left ventricle (LV) in diastolic T1 maps were greater than systolic T1 maps, either with fixed or HRD sampling scheme (all P T1 mapping with heart-rate-dependent pulse sequence scheme

  5. Usefulness of the SPACE pulse sequence at 1.5T MR cholangiography: comparison of image quality and image acquisition time with conventional 3D-TSE sequence.

    Science.gov (United States)

    Nakaura, Takeshi; Kidoh, Masafumi; Maruyama, Natsuki; Kawahara, Tetsuya; Namimoto, Tomohiro; Sakai, Yoshinari; Harada, Kazunori; Yamashita, Yasuyuki

    2013-11-01

    To prospectively evaluate the image quality and image acquisition time at 3D magnetic resonance cholangiopancreatography (MRCP) using sampling perfection with application optimized contrasts (SPACE) and conventional turbo-spin-echo (TSE) sequences. We acquired navigator-triggered SPACE and conventional 3D-TSE MRCP images using the same parameters where possible for 30 patients and compared the image acquisition time, contrast, and contrast-to-noise ratio (CNR) of the common bile duct (CBD). Two radiologists performed qualitative analyses using a 4-point scale. Image acquisition time was 31% shorter with the SPACE than the conventional TSE sequence (248.9 ± 73.0 sec vs. 360.5 ± 99.9 sec, P TSE (39.4 ± 14.7 vs. 33.5 ± 14.2, P TSE sequence; there was a significant difference in motion artifacts and the depiction of the CBD and the left hepatic and main pancreatic duct (P TSE. Copyright © 2013 Wiley Periodicals, Inc.

  6. SU-E-J-224: Using UTE and T1 Weighted Spin Echo Pulse Sequences for MR-Only Treatment Planning; Phantom Study

    Energy Technology Data Exchange (ETDEWEB)

    Yu, H; Fatemi, A [Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Sahgal, A [University of Toronto, Toronto, ON (Canada)

    2015-06-15

    Purpose: Investigating a new approach in MRI based treatment planning using the combination of (Ultrashort Echo Time) UTE and T1 weighted spin echo pulse sequences to delineate air, bone and water (soft tissues) in generating pseudo CT images comparable with CT. Methods: A gel phantom containing chicken bones, ping pang balls filled with distilled water and air bubbles, was made. It scanned with MRI using UTE and 2D T1W SE pulse sequences with (in plane resolution= 0.53mm, slice thickness= 2 mm) and CT with (in plane resolution= 0.5 mm and slice thickness= 0.75mm) as a ground truth for geometrical accuracy. The UTE and T1W SE images were registered with CT using mutual information registration algorithm provided by Philips Pinnacle treatment planning system. The phantom boundaries were detected using Canny edge detection algorithm for CT, and MR images. The bone, air bubbles and water in ping pong balls were segmented from CT images using threshold 300HU, - 950HU and 0HU, respectively. These tissue inserts were automatically segmented from combined UTE and T1W SE images using edge detection and relative intensity histograms of the phantom. The obtained segmentations of air, bone and water inserts were evaluated with those obtained from CT. Results: Bone and air can be clearly differentiated in UTE images comparable to CT. Combining UTE and T1W SE images successfully segmented the air, bone and water. The maximum segmentation differences from combine MRI images (UTE and T1W SE) and CT are within 1.3 mm, 1.1mm for bone, air, respectively. The geometric distortion of UTE sequence is small less than 1 pixel (0.53 mm) of MR image resolution. Conclusion: Our approach indicates that MRI can be used solely for treatment planning and its quality is comparable with CT.

  7. Development of Pseudorandom Binary Arrays for Calibration of Surface Profile Metrology Tools

    Energy Technology Data Exchange (ETDEWEB)

    Barber, S.K.; Takacs, P.; Soldate, P.; Anderson, E.H.; Cambie, R.; McKinney, W.R.; Voronov, D.L.; Yashchuk, V.V.

    2009-12-01

    measured and simulated PSD distributions gives the MTF of the instrument. The applicability of the MTF concept to phase map measurements with optical interferometric microscopes needs to be experimentally verified as the optical tool and algorithms may introduce nonlinear artifacts into the process. In previous work [V. V. Yashchuk et al., Proc. SPIE 6704, 670408 (2007); Valeriy V. Yashchuk et al., Opt. Eng. (Bellingham) 47, 073602 (2008)] the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on binary pseudorandom (BPR) gratings. Here, the authors present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as global position systems and wireless communication protocols. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the uniformly redundant array (URA) prescription [E. E. Fenimore and T. M. Cannon, Appl. Opt. 17, 337 (1978)] initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat PSD. Three different size BPR array patterns were fabricated by electron beam lithography and induction coupled plasma etching of silicon. The basic size units were 200, 400, and 600 nm. Two different etch processes were used, CF{sub 4}/Ar and HBr, which resulted in undercut and vertical sidewall profiles, respectively. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope using all available objectives. The MicroMap{trademark}-570 interferometric microscope uses incoherent illumination from a tungsten filament source and

  8. SU-E-T-558: An Exploratory RF Pulse Sequence Technique Used to Induce Differential Heating in Tissues Containing Iron Oxide Nanoparticles for a Possible Hyperthermic Adjuvant Effect to Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yee, S; Ionascu, D; Wilson, G [William Beaumont Hospital, Royal Oak, MI (United States); Thapa, R [Oakland University, Rochester, MI (United States)

    2014-06-01

    Purpose: In pre-clinical trials of cancer thermotherapy, hyperthermia can be induced by exposing localized super-paramagnetic iron oxide nanoparticles (SPION) to external alternating magnetic fields generated by a solenoid electrical circuit (Zhao et al., Theranostics 2012). Alternatively, an RF pulse technique implemented in a regular MRI system is explored as a possible hyperthermia induction technique . Methods: A new thermal RF pulse sequence was developed using the Philips pulse programming tool for the 3T Ingenia MRI system to provide a sinusoidal magnetic field alternating at the frequency of 1.43 kHz (multiples of sine waves of 0.7 ms period) before each excitation RF pulse for imaging. The duration of each thermal RF pulse routine was approximately 3 min, and the thermal pulse was applied multiple times to a phantom that contains different concentrations (high, medium and low) of SPION samples. After applying the thermal pulse each time, the temperature change was estimated by measuring the phase changes in the T1-weighted inversion-prepared multi-shot turbo field echo (TFE) sequence (TR=5.5 ms, TE=2.7 ms, inversion time=200 ms). Results: The phase values and relative differences among them changed as the number of applied thermal RF pulses increased. After the 5th application of the thermal RF pulse, the relative phase differences increased significantly, suggesting the thermal activation of the SPION. The increase of the phase difference was approximately linear with the SPION concentration. Conclusion: A sinusoidal RF pulse from the MRI system may be utilized to selectively thermally activate tissues containing super-paramagnetic iron oxide nanoparticles.

  9. Molecular epidemiology of Neisseria gonorrhoeae using multi-antigen sequence typing and pulse-field gel electrophoresis in highly endemic Western Australian populations.

    Science.gov (United States)

    O'Reilly, Lyn C; Goire, Namraj; Fisk, Rachel E; Speers, David J

    2015-07-15

    The remote and indigenous populations of Western Australia (WA) have one of the highest notification rates of gonorrhoea in the world. Despite this, the low rate of antimicrobial resistance in Neisseria gonorrhoeae from these regions permits the use of amoxycillin as empirical therapy. We describe the first molecular epidemiological study of gonococci isolated from this population using two different typing platforms. Pulse-field gel electrophoresis (PFGE), Neisseria gonorrhoeae multi-antigen sequence typing (NG-MAST) and antimicrobial susceptibility tests were performed on 128 consecutive N. gonorrhoeae isolates cultured between January 2011 and December 2013. To highlight clusters isolates were evaluated based on their tbpB sequence types. No predominant NG-MAST or PFGE types were found. A total of 67 distinct PFGE pulsotypes were identified amongst the 128 isolates in this study with 20 PFGE pulsotypes representing 78 isolates. A total of 59 NG-MAST sequence types were found, represented by 45 porB alleles and 28 tbpB alleles with 13 tbpB genomogroups from 45 NG-MAST sequence types. TbpB genomogroup 29, represented by 45 isolates, was by far the most common genomogroup overall. Results from this study suggest that gonococcal epidemiology in WA is quite different between remote regions and major population centres and, in some cases, geographically restricted. It is likely that isolates originating from endemic regions of WA mostly represent independent, small sexual networks with an infrequent interchange between other communities and regions. Given the high rate of antimicrobial resistance elsewhere in Australia, ongoing surveillance is essential to ensure the enduring efficacy of amoxycillin empiric use in the remote regions of WA.

  10. Three-dimensional isotropic fast spin-echo MR lymphangiography of T1-weighted and intermediate-weighted pulse sequences in patients with lymphoedema.

    Science.gov (United States)

    Jeon, J Y; Lee, S H; Shin, M J; Chung, H W; Lee, M H

    2016-01-01

    To evaluate the feasibility of magnetic resonance (MR) lymphangiography acquired using three-dimensional (3D) isotropic T1-weighted fast spin-echo (FSE) and 3D isotropic intermediate-weighted FSE sequences, as the new method of MR lymphangiography, and to compare the results of these two methods in patients with lymphoedema. Thirty-three extremities of 27 patients with primary or secondary lymphoedema and who had undergone radionuclide lymphoscintigraphy and MR lymphangiography with 3D isotropic T1-weighted FSE and 3D isotropic intermediate-weighted FSE were included in the study. The results of both imaging techniques were independently reviewed by two readers in consensus who rated the lymphatic drainage pattern, the quality of the depiction of lymphatic vessels and lymph nodes, and the level of lymph vessel enhancement. The assessment scores of each imaging sequence were compared using the Wilcoxon signed-rank test. The results were expressed as means with standard deviations. More lymphatic vessels were visualised on T1-weighted FSE than on intermediate-weighted FSE (plymphatic vessels were detected on T1-weighted FSE, the per-extremity grade of the lymphatic drainage pattern was higher (p=0.046) and the visible levels of lymph-vessel enhancement were also significantly higher (p=0.004) on the T1-weighted FSE sequence, whereas the conspicuity of lymph nodes was superior on intermediate-weighted FSE (p=0.004). MR lymphangiography using the 3D FSE pulse sequence is a feasible and noticeable new technique of MR lymphangiography. Between the two applicable protocols used, T1-weighted FSE provided better information regarding lymphatic vessels and their drainage, whereas intermediate-weighted FSE has the advantage of depicting lymph nodes in lymphoedematous extremities. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  11. Laboratory Investigation of Salmonella enterica serovar Poona Outbreak in California: Comparison of Pulsed-Field Gel Electrophoresis (PFGE) and Whole Genome Sequencing (WGS) Results.

    Science.gov (United States)

    Kozyreva, Varvara K; Crandall, John; Sabol, Ashley; Poe, Alyssa; Zhang, Peng; Concepción-Acevedo, Jeniffer; Schroeder, Morgan N; Wagner, Darlene; Higa, Jeffrey; Trees, Eija; Chaturvedi, Vishnu

    2016-11-22

    Recently, Salmonella enterica serovar Poona caused a multistate outbreak, with 245 out of 907 cases occurring in California. We report a comparison of pulsed-field gel electrophoresis (PFGE) results with whole genome sequencing (WGS) for genotyping of Salmonella Poona isolates. CA Salmonella Poona isolates, collected from July to August 2015, were genotyped by PFGE using XbaI restriction enzyme. WGS was done using Nextera XT library kit with 2x300 bp or 2x250 bp sequencing chemistry on the Illumina MiSeq Sequencer.  Reads were mapped to the de novo assembled serovar Poona draft genome (48 contigs, N50= 223,917) from the outbreak using CLCbio GW 8.0.2. The phylogenetic tree was generated based on hqSNPs calling. Genomes were annotated with CGE and PHAST online tools. In silico MLST was performed using the CGE online tool. Human (14) and cucumber (2) Salmonella Poona isolates exhibited 3 possibly related PFGE patterns (JL6X01.0018 [predominant], JL6X01.0375, JL6X01.0778).  All isolates that were related by PFGE also clustered together according to the WGS. One isolate with a divergent PFGE pattern (JL6X01.0776) served as an outlier in the phylogenetic analysis and substantially differed from the outbreak clade by WGS. All outbreak isolates were assigned to MLST sequence type 447. The majority of the outbreak-related isolates possessed the same set of Salmonella Pathogenicity Islands with few variations. One outbreak isolate was sequenced and analyzed independently by CDC and CDPH laboratories; there was 0 SNP difference in results. Additional two isolates were sequenced by CDC and the raw data was processed through CDPH and CDC analysis pipelines. Both data analysis pipelines also generated concordant results.  Discussion: PFGE and WGS results for the recent CA Salmonella enterica serovar Poona outbreak provided concordant assignment of the isolates to the outbreak cluster. WGS allowed more robust determination of genetic relatedness, provided information

  12. Molecular Typing of Fluoroquinolone-Resistant Campylobacter jejuni Isolated from Broilers in Japan Using Multilocus Sequence Typing and Pulsed-Field Gel Electrophoresis.

    Science.gov (United States)

    Ozawa, Manao; Hiki, Mototaka; Kawanishi, Michiko; Abo, Hitoshi; Kojima, Akemi; Asai, Tetsuo; Hamamoto, Shuichi

    2016-01-01

    Fluoroquinolone-resistant Campylobacter jejuni isolates from broilers in Japan were characterized using multilocus sequence typing and pulsed-field gel electrophoresis (PFGE) in order to elucidate the genetic relationship between these strains. Forty-three of the isolates were classified into 20 sequence types and were clustered into 21 PFGE types with 70% similarity. The most dominant clonal complex (CC) was CC-21 (41.9%). Diverse PFGE patterns were observed within the same CC, but the combined analysis of PFGE type and CC revealed that the strains with the same combination were isolated from the same district or neighboring districts. On the other hand, strains with the same combination pattern were also isolated from geographically distant districts. Our results elucidate two possible reasons for the prevalence of fluoroquinolone-resistant C. jejuni among broiler farms: (1) the resistant C. jejuni is clonally disseminated within the limited area, and (2) susceptible C. jejuni acquired fluoroquinolone resistance during the use of fluoroquinolone on the farms.

  13. Genetic characterization of atypical enteropathogenic Escherichia coli isolates from ewes' milk, sheep farm environments, and humans by multilocus sequence typing and pulsed-field gel electrophoresis.

    Science.gov (United States)

    Otero, Verónica; Rodríguez-Calleja, José-María; Otero, Andrés; García-López, María-Luisa; Santos, Jesús A

    2013-10-01

    A collection of 81 isolates of enteropathogenic Escherichia coli (EPEC) was obtained from samples of bulk tank sheep milk (62 isolates), ovine feces (4 isolates), sheep farm environment (water, 4 isolates; air, 1 isolate), and human stool samples (9 isolates). The strains were considered atypical EPEC organisms, carrying the eae gene without harboring the pEAF plasmid. Multilocus sequence typing (MLST) was carried out with seven housekeeping genes and 19 sequence types (ST) were detected, with none of them having been previously reported for atypical EPEC. The most frequent ST included 41 strains isolated from milk and human stool samples. Genetic typing by pulsed-field gel electrophoresis (PFGE) resulted in 57 patterns which grouped in 24 clusters. Comparison of strains isolated from the different samples showed phylogenetic relationships between milk and human isolates and also between milk and water isolates. The results obtained show a possible risk for humans due to the presence of atypical EPEC in ewes' milk and suggest a transmission route for this emerging pathogen through contaminated water.

  14. High Genetic Diversity of Enterococcus faecium and Enterococcus faecalis Clinical Isolates by Pulsed-Field Gel Electrophoresis and Multilocus Sequence Typing from a Hospital in Malaysia

    Directory of Open Access Journals (Sweden)

    Poh Leng Weng

    2013-01-01

    Full Text Available Little is known on the genetic relatedness and potential dissemination of particular enterococcal clones in Malaysia. We studied the antibiotic susceptibility profiles of Enterococcus faecium and Enterococcus faecalis and subjected them to pulsed-field gel electrophoresis (PFGE and multilocus sequence typing (MLST. E. faecium and E. faecalis displayed 27 and 30 pulsotypes, respectively, and 10 representative E. faecium and E. faecalis isolates (five each yielded few different sequence types (STs: ST17 (2 isolates, ST78, ST203, and ST601 for E. faecium, and ST6, ST16, ST28, ST179, and ST399 for E. faecalis. Resistance to tazobactam-piperacillin and ampicillin amongst E. faecium isolates was highly observed as compared to E. faecalis isolates. All of the isolates were sensitive to vancomycin and teicoplanin. The presence of epidemic and nosocomial strains of selected E. faecium STs: 17, 78, and 203 and E. faecalis ST6 as well as high rates of resistance to multiple antibiotics amongst E. faecium isolates is of a particular concern.

  15. High genetic diversity of Enterococcus faecium and Enterococcus faecalis clinical isolates by pulsed-field gel electrophoresis and multilocus sequence typing from a hospital in Malaysia.

    Science.gov (United States)

    Weng, Poh Leng; Ramli, Ramliza; Shamsudin, Mariana Nor; Cheah, Yoke-Kqueen; Hamat, Rukman Awang

    2013-01-01

    Little is known on the genetic relatedness and potential dissemination of particular enterococcal clones in Malaysia. We studied the antibiotic susceptibility profiles of Enterococcus faecium and Enterococcus faecalis and subjected them to pulsed-field gel electrophoresis (PFGE) and multilocus sequence typing (MLST). E. faecium and E. faecalis displayed 27 and 30 pulsotypes, respectively, and 10 representative E. faecium and E. faecalis isolates (five each) yielded few different sequence types (STs): ST17 (2 isolates), ST78, ST203, and ST601 for E. faecium, and ST6, ST16, ST28, ST179, and ST399 for E. faecalis. Resistance to tazobactam-piperacillin and ampicillin amongst E. faecium isolates was highly observed as compared to E. faecalis isolates. All of the isolates were sensitive to vancomycin and teicoplanin. The presence of epidemic and nosocomial strains of selected E. faecium STs: 17, 78, and 203 and E. faecalis ST6 as well as high rates of resistance to multiple antibiotics amongst E. faecium isolates is of a particular concern.

  16. Volumetric MRI thermometry using a three-dimensional stack-of-stars echo-planar imaging pulse sequence.

    Science.gov (United States)

    Jonathan, Sumeeth V; Grissom, William A

    2017-08-07

    To measure temperature over a large brain volume with fine spatiotemporal resolution. A three-dimensional stack-of-stars echo-planar imaging sequence combining echo-planar imaging and radial sampling with golden angle spacing was implemented at 3T for proton resonance frequency-shift temperature imaging. The sequence acquires a 188x188x43 image matrix with 1.5x1.5x2.75 mm3 spatial resolution. Temperature maps were reconstructed using sensitivity encoding (SENSE) image reconstruction followed by the image domain hybrid method, and using the k-space hybrid method. In vivo temperature maps were acquired without heating to measure temperature precision in the brain, and in a phantom during high-intensity focused ultrasound sonication. In vivo temperature standard deviation was less than 1°C at dynamic scan times down to 0.75 s. For a given frame rate, scanning at a minimum repetition time (TR) with minimum acceleration yielded the lowest standard deviation. With frame rates around 3 s, the scan was tolerant to a small number of receive coils, and temperature standard deviation was 48% higher than a standard two-dimensional Fourier transform temperature mapping scan, but provided whole-brain coverage. Phantom temperature maps with no visible aliasing were produced for dynamic scan times as short as 0.38 s. k-Space hybrid reconstructions were more tolerant to acceleration. Three-dimensional stack-of-stars echo-planar imaging temperature mapping provides volumetric brain coverage and fine spatiotemporal resolution. Magn Reson Med, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  17. Calibration of the Modulation Transfer Function of Surface Profilometers with Binary Pseudorandom Test Standards: Expanding the Application Range to Fizeau Interferometers and Electron Microscopes

    Energy Technology Data Exchange (ETDEWEB)

    Yashchuk, V.V.; Takacs, P.; Anderson, E.H.; Barber, S.K.; Bouet, N.; Cambie, R.; Conley, R.; McKinney, W.R.; Voronov, D.L.

    2011-09-16

    A modulation transfer function (MTF) calibration method based on binary pseudorandom (BPR) gratings and arrays has been proven to be an effective MTF calibration method for interferometric microscopes and a scatterometer. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 in. phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to the BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

  18. Binary pseudo-random patterned structures for modulation transfer function calibration and resolution characterization of a full-field transmission soft x-ray microscope

    Energy Technology Data Exchange (ETDEWEB)

    Yashchuk, V. V., E-mail: VVYashchuk@lbl.gov; Chan, E. R.; Lacey, I. [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Fischer, P. J. [Center for X-Ray Optics, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Physics Department, University of California Santa Cruz, Santa Cruz, California 94056 (United States); Conley, R. [Advance Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States); National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, New York 11973 (United States); McKinney, W. R. [Diablo Valley College, 321 Golf Club Road, Pleasant Hill, California 94523 (United States); Artemiev, N. A. [KLA-Tencor Corp., 1 Technology Drive, Milpitas, California 95035 (United States); Bouet, N. [National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, New York 11973 (United States); Cabrini, S. [Molecular Foundry, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Calafiore, G.; Peroz, C.; Babin, S. [aBeam Technologies, Inc., Hayward, California 94541 (United States)

    2015-12-15

    We present a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) one-dimensional sequences and two-dimensional arrays as an effective method for spectral characterization in the spatial frequency domain of a broad variety of metrology instrumentation, including interferometric microscopes, scatterometers, phase shifting Fizeau interferometers, scanning and transmission electron microscopes, and at this time, x-ray microscopes. The inherent power spectral density of BPR gratings and arrays, which has a deterministic white-noise-like character, allows a direct determination of the MTF with a uniform sensitivity over the entire spatial frequency range and field of view of an instrument. We demonstrate the MTF calibration and resolution characterization over the full field of a transmission soft x-ray microscope using a BPR multilayer (ML) test sample with 2.8 nm fundamental layer thickness. We show that beyond providing a direct measurement of the microscope’s MTF, tests with the BPRML sample can be used to fine tune the instrument’s focal distance. Our results confirm the universality of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

  19. Binary Pseudo-Random Gratings and Arrays for Calibration of Modulation Transfer Functions of Surface Profilometers

    Energy Technology Data Exchange (ETDEWEB)

    Barber, Samuel K.; Anderson, Erik D.; Cambie, Rossana; McKinney, Wayne R.; Takacs, Peter Z.; Stover, John C.; Voronov, Dmitriy L.; Yashchuk, Valeriy V.

    2009-09-11

    A technique for precise measurement of the modulation transfer function (MTF), suitable for characterization of a broad class of surface profilometers, is investigated in detail. The technique suggested in [Proc. SPIE 7077-7, (2007), Opt. Eng. 47(7), 073602-1-5 (2008)]is based on use of binary pseudo-random (BPR) gratings and arrays as standard MTF test surfaces. Unlike most conventional test surfaces, BPR gratings and arrays possess white-noise-like inherent power spectral densities (PSD), allowing the direct determination of the one- and two-dimensional MTF, respectively, with a sensitivity uniform over the entire spatial frequency range of a profiler. In the cited work, a one dimensional realization of the suggested method based on use of BPR gratings has been demonstrated. Here, a high-confidence of the MTF calibration technique is demonstrated via cross comparison measurements of a number of two dimensional BPR arrays using two different interferometric microscopes and a scatterometer. We also present the results of application of the experimentally determined MTF correction to the measurement taken with the MicromapTM-570 interferometric microscope of the surface roughness of a super-polished test mirror. In this particular case, without accounting for the instrumental MTF, the surface rms roughness over half of the instrumental spatial frequency bandwidth would be underestimated by a factor of approximately 1.4.

  20. A Computer Controlled Pulse Programmer for Pulsed NQR Experiments

    OpenAIRE

    Horiuchi, Keizo; 堀内, 敬三

    1987-01-01

    We constructed a computer controlled pulse programmer for the measurement of nuclear quadrupole resonance relaxation times. Programmable interval timer 8253 was used as device for pulse programming. The circuit is very simple and construction is also easy in comparison with the usual pulse programmer. This programmer is sufficiently useful concerning the pulse programming of slimple pulse sequences such as π-τ-π/2 and π/2-τ-π, which are usually used in the measurement of relaxation times. We ...

  1. Enhancing the gate fidelity of silicon-based singlet-triplet qubits under symmetric exchange control using optimized pulse sequences

    Science.gov (United States)

    Zhang, Chengxian; Throckmorton, Robert; Yang, Xu-Chen; Wang, Xin; Barnes, Edwin

    We perform Randomized Benchmarking of a family of recently introduced control scheme for singlet-triplet qubits in semiconductor double quantum dots, which is optimized to have substantially shorter gate times. We study their performances under the recently introduced symmetric control scheme of changing the exchange interaction by raising and lowering the barrier between the two dots (barrier control) and compare these results to those under the traditional tilt control method in which the exchange interaction is varied by detuning. It has been suggested that the barrier control method encounters a much smaller charge noise. We found that for the cases where the charge noise is dominant, corresponding to the device made on isotopically enriched silicon, the optimized sequences offer much longer coherence time under barrier control compared to the tilt control method of the strength of the exchange interaction. This work was supported by the Research Grants Council of Hong Kong SAR (No. CityU 21300116) and the National Natural Science Foundation of China (No. 11604277), and by LPS-MPO-CMTC.

  2. Visual-vestibular interaction during head-free pursuit of pseudorandom target motion in man.

    Science.gov (United States)

    Waterston, J A; Barnes, G R

    1992-01-01

    Recordings of head and eye movement were made during pursuit of mixed-frequency, pseudorandom target motion to study the mechanism of vestibulo-ocular reflex (VOR) suppression during head-free pursuit. When high velocity stimuli were used, slow-phase gaze velocity gains decreased significantly with increases in both absolute target velocity and the velocity ratio between the frequency components. These changes occurred independently of changes in the head displacement gain, which remained relatively constant at the lower frequency and were directly attributable to impaired suppression of the VOR. Similar effects were seen when visual feedback was degraded by tachistoscopic illumination of the target. The results indicate that visual feedback, rather than an efference copy of the head velocity signal, is essential for suppression of slow-phase vestibular eye movement during head-free pursuit. When head-free and head-fixed pursuit were compared, striking similarities were seen for both slow phase gaze velocity gain and phase, indicating that gaze control during smooth pursuit is largely independent of the degree of associated head movement. This suggests that the VOR is not switched off during head-free pursuit. An estimate of the underlying VOR gain was obtained by recording the vestibular response produced by active head movements in darkness. The rather higher estimates of VOR gain obtained using an imaginary earth-fixed target paradigm were found to predict head-free gains more closely than the gains obtained during imaginary pursuit of a moving target, suggesting that such measures may be more representative of the underlying VOR gain.

  3. Optimizing contrast agent concentration and spoiled gradient echo pulse sequence parameters for catheter visualization in MR-guided interventional procedures: an analytic solution.

    Science.gov (United States)

    Sussman, Marshall S; Lindner, Uri; Haider, Masoom; Kucharczyk, Walter; Hlasny, Eugen; Trachtenberg, John

    2013-08-01

    A critical requirement of MR-guided interventions is the visualization of an instrument (e.g., catheter, needle) during the procedure. One approach is to fill the instrument with a contrast agent. Previously, the optimization of contrast agent visualization was performed only empirically. In the present study, an analytic optimization of contrast agent SNR efficiency was performed for a spoiled gradient echo pulse sequence. Optimal flip angle, repetition time, echo time, and contrast agent concentration were derived analytically. The solution is valid for any contrast agent, provided the relationship between T1 , T2 , and doping concentration is known. Phantom experiments validated the analytic optimization for Gd- and MnCl2 -based contrast agents. Results showed excellent agreement between experimentally predicted and theoretically observed magnetization behavior. In vivo experiments demonstrated optimized contrast agent visualization in brain, heart, and prostate applications. The results demonstrated the large SNR that can be achieved with analytic optimization. As a practical guideline, an 11% dilution of 500 mMol/L Gd-DTPA solution, repetition time ≈ 4 ms, echo time ≈ 1 ms, and θ ≈ 65° was found to provide a large SNR. This study derived and validated a method for analytically optimizing contrast agent SNR efficiency. This information may be useful for visualizing instruments during MR-guided interventions. © 2013 Wiley Periodicals, Inc.

  4. Investigation into the structural composition of hydroalcoholic solutions as basis for the development of multiple suppression pulse sequences for NMR measurement of alcoholic beverages.

    Science.gov (United States)

    Monakhova, Yulia B; Mushtakova, Svetlana P; Kuballa, Thomas; Lachenmeier, Dirk W

    2014-12-01

    An eight-fold suppression pulse sequence was recently developed to improve sensitivity in (1) H NMR measurements of alcoholic beverages [Magn. Res. Chem. 2011 (49): 734-739]. To ensure that only one combined hydroxyl peak from water and ethanol appears in the spectrum, adjustment to a certain range of ethanol concentrations was required. To explain this observation, the structure of water-ethanol solutions was studied. Hydroalcoholic solutions showed extreme behavior at 25% vol, 46% vol, and 83% vol ethanol according to (1) H NMR experiments. Near-infrared spectroscopy confirmed the occurrence of four significant compounds ('individual' ethanol and water structures as well as two water-ethanol complexes of defined composition - 1 : 1 and 1 : 3). The successful multiple suppression can be achieved for every kind of alcoholic beverage with different alcoholic strengths, when the final ethanol concentration is adjusted to a range between 25% vol and 46% vol (e.g. using dilution or pure ethanol addition). In this optimum region, an individual ethanol peak was not detected, because the 'individual' water structure and the 1 : 1 ethanol-water complex predominate. The nature of molecular association in ethanol-water solutions is essential to elucidate NMR method development for measurement of alcoholic beverages. The presented approach can be used to optimize other NMR suppression protocols for binary water-organic solvent mixtures, where hydrogen bonding plays a dominant role. Copyright © 2014 John Wiley & Sons, Ltd.

  5. Simultaneous fMRI and local field potential measurements during epileptic seizures in medetomidine-sedated rats using raser pulse sequence.

    Science.gov (United States)

    Airaksinen, Antti M; Niskanen, Juha-Pekka; Chamberlain, Ryan; Huttunen, Joanna K; Nissinen, Jari; Garwood, Michael; Pitkänen, Asla; Gröhn, Olli

    2010-10-01

    Simultaneous electrophysiological and functional magnetic resonance imaging measurements of animal models of epilepsy are methodologically challenging, but essential to better understand abnormal brain activity and hemodynamics during seizures. In this study, functional magnetic resonance imaging of medetomidine-sedated rats was performed using novel rapid acquisition by sequential excitation and refocusing (RASER) fast imaging pulse sequence and simultaneous local field potential measurements during kainic acid-induced seizures. The image distortion caused by the hippocampal-measuring electrode was clearly seen in echo planar imaging images, whereas no artifact was seen in RASER images. Robust blood oxygenation level-dependent responses were observed in the hippocampus during kainic acid-induced seizures. The recurrent epileptic seizures were detected in the local field potential signal after kainic acid injection. The presented combination of deep electrode local field potential measurements and functional magnetic resonance imaging under medetomidine anesthesia, which does not significantly suppress kainic acid-induced seizures, provides a unique tool for studying abnormal brain activity in rats.

  6. On the short-term predictability of fully digital chaotic oscillators for pseudo-random number generation

    KAUST Repository

    Radwan, Ahmed Gomaa

    2014-06-18

    This paper presents a digital implementation of a 3rd order chaotic system using the Euler approximation. Short-term predictability is studied in relation to system precision, Euler step size and attractor size and optimal parameters for maximum performance are derived. Defective bits from the native chaotic output are neglected and the remaining pass the NIST SP. 800-22 tests without post-processing. The resulting optimized pseudorandom number generator has throughput up to 17.60 Gbits/s for a 64-bit design experimentally verified on a Xilinx Virtex 4 FPGA with logic utilization less than 1.85%.

  7. Pseudo-Random Mating Populations. in Celebration of the 80th Anniversary of the Hardy-Weinberg Law

    OpenAIRE

    Li, C. C.

    1988-01-01

    That random mating leads to Hardy-Weinberg distribution of genotypes is well known. This report is to show that, if the deviations from random mating are of a certain pattern, the offspring generation will also be in Hardy-Weinberg proportions. This brings out the fact that random mating is a sufficient condition, not a necessary one, for the attainment of the Hardy-Weinberg proportions. Such nonrandom-mating populations are tentatively said to be pseudo-random mating. Pseudo-random-mating po...

  8. Detection of M-Sequences from Spike Sequence in Neuronal Networks

    Directory of Open Access Journals (Sweden)

    Yoshi Nishitani

    2012-01-01

    Full Text Available In circuit theory, it is well known that a linear feedback shift register (LFSR circuit generates pseudorandom bit sequences (PRBS, including an M-sequence with the maximum period of length. In this study, we tried to detect M-sequences known as a pseudorandom sequence generated by the LFSR circuit from time series patterns of stimulated action potentials. Stimulated action potentials were recorded from dissociated cultures of hippocampal neurons grown on a multielectrode array. We could find several M-sequences from a 3-stage LFSR circuit (M3. These results show the possibility of assembling LFSR circuits or its equivalent ones in a neuronal network. However, since the M3 pattern was composed of only four spike intervals, the possibility of an accidental detection was not zero. Then, we detected M-sequences from random spike sequences which were not generated from an LFSR circuit and compare the result with the number of M-sequences from the originally observed raster data. As a result, a significant difference was confirmed: a greater number of “0–1” reversed the 3-stage M-sequences occurred than would have accidentally be detected. This result suggests that some LFSR equivalent circuits are assembled in neuronal networks.

  9. Pseudo-random data acquisition geometry in 3D seismic survey; Sanjigen jishin tansa ni okeru giji random data shutoku reiauto ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Minegishi, M.; Tsuburaya, Y. [Japan National Oil Corp., Tokyo (Japan). Technology Research Center

    1996-10-01

    Influence of pseudo-random geometry on the imaging for 3D seismic exploration data acquisition has been investigate using a simple model by comparing with the regular geometry. When constituting wave front by the interference of elemental waves, pseudo-random geometry data did not always provide good results. In the case of a point diffractor, the imaging operation, where the constituted wave front was returned to the point diffractor by the interference of elemental waves for the spatial alias records, did not always give clear images. In the case of multi point diffractor, good images were obtained with less noise generation in spite of alias records. There are a lot of diffractors in the actual geological structures, which corresponds to the case of multi point diffractors. Finally, better images could be obtained by inputting records acquired using the pseudo-random geometry rather than by inputting spatial alias records acquired using the regular geometry. 7 refs., 6 figs.

  10. Generation of brain pseudo-CTs using an undersampled, single-acquisition UTE-mDixon pulse sequence and unsupervised clustering

    Energy Technology Data Exchange (ETDEWEB)

    Su, Kuan-Hao [Case Center for Imaging Research, Case Western Reserve University, Cleveland, Ohio 44106 and Department of Radiology, University Hospitals Case Medical Center, Case Western Reserve University, Cleveland, Ohio 44106 (United States); Hu, Lingzhi; Traughber, Melanie [Philips Healthcare, Cleveland, Ohio 44143 (United States); Stehning, Christian; Helle, Michael [Philips Research, Hamburg 22335 (Germany); Qian, Pengjiang [School of Digital Media, Jiangnan University, Jiangsu 214122 (China); Thompson, Cheryl L. [Departments of Family Medicine and Community Health and Epidemiology and Biostatistics, Case Western Reserve University, Cleveland, Ohio 44106 and Case Comprehensive Cancer Center, Case Western Reserve University, Cleveland, Ohio 44106 (United States); Pereira, Gisele C.; Traughber, Bryan J., E-mail: bryan.traughber@case.edu [Department of Radiation Oncology, University Hospitals Seidman Cancer Center, Case Western Reserve University, Cleveland, Ohio 44106 (United States); Jordan, David W. [Department of Radiology, University Hospitals Case Medical Center, Case Western Reserve University, Cleveland, Ohio 44106 (United States); Herrmann, Karin A. [Department of Radiology, University Hospitals Case Medical Center, Case Western Reserve University, Cleveland, Ohio 44106 and Case Comprehensive Cancer Center, Case Western Reserve University, Cleveland, Ohio 44106 (United States); Muzic, Raymond F. [Case Center for Imaging Research, Case Western Reserve University, Cleveland, Ohio 44106 (United States); Department of Radiology, University Hospitals Case Medical Center, Case Western Reserve University, Cleveland, Ohio 44106 (United States); Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106 (United States)

    2015-08-15

    Purpose: MR-based pseudo-CT has an important role in MR-based radiation therapy planning and PET attenuation correction. The purpose of this study is to establish a clinically feasible approach, including image acquisition, correction, and CT formation, for pseudo-CT generation of the brain using a single-acquisition, undersampled ultrashort echo time (UTE)-mDixon pulse sequence. Methods: Nine patients were recruited for this study. For each patient, a 190-s, undersampled, single acquisition UTE-mDixon sequence of the brain was acquired (TE = 0.1, 1.5, and 2.8 ms). A novel method of retrospective trajectory correction of the free induction decay (FID) signal was performed based on point-spread functions of three external MR markers. Two-point Dixon images were reconstructed using the first and second echo data (TE = 1.5 and 2.8 ms). R2{sup ∗} images (1/T2{sup ∗}) were then estimated and were used to provide bone information. Three image features, i.e., Dixon-fat, Dixon-water, and R2{sup ∗}, were used for unsupervised clustering. Five tissue clusters, i.e., air, brain, fat, fluid, and bone, were estimated using the fuzzy c-means (FCM) algorithm. A two-step, automatic tissue-assignment approach was proposed and designed according to the prior information of the given feature space. Pseudo-CTs were generated by a voxelwise linear combination of the membership functions of the FCM. A low-dose CT was acquired for each patient and was used as the gold standard for comparison. Results: The contrast and sharpness of the FID images were improved after trajectory correction was applied. The mean of the estimated trajectory delay was 0.774 μs (max: 1.350 μs; min: 0.180 μs). The FCM-estimated centroids of different tissue types showed a distinguishable pattern for different tissues, and significant differences were found between the centroid locations of different tissue types. Pseudo-CT can provide additional skull detail and has low bias and absolute error of

  11. A novel effect of Noscapine on patients with massive ischemic stroke: A pseudo-randomized clinical trial.

    Science.gov (United States)

    Mahmoudian, Massoud; Rezvani, Mohammad; Rohani, Mohammad; Benaissa, Foozya; Jalili, Mehdi; Ghourchian, Shadi

    2015-01-05

    Massive ischemic stroke causes significant mortality and morbidity in stroke patients. The main treatments for massive ischemic stroke are recombinant tissue plasminogen activator (rtPA), craniotomy, and endovascular interventions. Due to destructive effects of bradykinin on the nervous system in ischemic stroke, it seems reasonable that using Noscapine as a Bradykinin antagonist may improve patients' outcome after ischemic stroke. The effect of Noscapine on massive ischemic stroke was shown by the previous pilot study by our group. This pseudo-randomized clinical trial study was designed to assess the result of the pilot study. Patients who had clinical symptoms or computed tomography scan indicative of massive stroke (in full middle cerebral artery territory) were entered to the study. The cases received the drugs according to their turns in emergency ward (pseudo-randomized). The patient group received Noscapine, and the control group received common supportive treatments. The patients and data analyzer were blinded about the data. At the end of the study, to adjust confounding variables we used logistic regression. After 1-month follow-up, 16 patients in the control group and 11 patients in the case group expired (P = 0.193). Analyzing the data extracted from Rankin scale and Barthel index check lists, revealed no significant differences in the two groups. Despite the absence of significant statistical results in our study, the reduction rate of 16% for mortality rate in Noscapine recipients is clinically remarkable and motivates future studies with larger sample sizes.

  12. Semi-automated repetitive-sequence-based polymerase chain reaction compared to pulsed-field gel electrophoresis for Listeria monocytogenes subtyping.

    Science.gov (United States)

    Roussel, Sophie; Félix, Benjamin; Colanéri, Cécile; Vignaud, Marie-Léone; Dao, Trinh Tam; Marault, Muriel; Brisabois, Anne

    2010-09-01

    Listeriosis is a severe infection that mainly affects pregnant women, neonates, and immuno-compromised adults. The commercially available semi-automated repetitive-sequence-based polymerase chain reaction assay system, DiversiLab, has been successfully used for subtyping several species of bacteria. In this article we compare the DiversiLab System with macrorestriction analysis by pulsed-field gel electrophoresis (PFGE), which is currently the gold standard for molecular subtyping of Listeria monocytogenes. We used a panel of 116 human and food L. monocytogenes isolates for the comparative evaluation. Among these isolates, there were 4 pairs of duplicates, 13 strains were epidemiologically related, and the remaining food isolates were epidemiologically unrelated. The isolates of different serotypes represented distinct DiversiLab types (DTs) and ApaI/AscI-PFGE types except for one DT-containing isolates of two serotypes, 4b and 1/2b. The four duplicates displayed the same DT and ApaI/AscI PFGE type demonstrating the good reproducibility of the two methods. The epidemiologically related strains were clustered in the same DT and PFGE type. The Simpson's index of diversity was 0.954; 0.988; 0.994; and 0.998 for DiversiLab, AscI-PFGE, ApaI-PFGE, and AscI/ApaI-PFGE, respectively. Thus, PFGE was more discriminating than DiversiLab. However, for 1/2a serotype strains, six AscI-PFGE, three ApaI-PFGE, and one ApaI/AscI PFGE type were divided into different DTs. DiversiLab enabled a good discrimination between serotype 1/2a strains. DiversiLab is less labor intensive than PFGE and provides results in <24 hours compared with 30 hours to 3 days for PFGE from the time a pure culture of the bacteria has been obtained. On the basis of these results, DiversiLab may be useful for tracking the source of contamination in food-processing facilities and their environments. Also, DiversiLab may be more appropriate for long-term epidemiological studies where less discrimination is needed.

  13. Optimized AIR and investigational MOLLI cardiac T1 mapping pulse sequences produce similar intra-scan repeatability in patients at 3T.

    Science.gov (United States)

    Hong, KyungPyo; Collins, Jeremy; Lee, Daniel C; Wilcox, Jane E; Markl, Michael; Carr, James; Kim, Daniel

    2016-10-01

    This study was conducted to improve the precision of arrhythmia-insensitive rapid (AIR) cardiac T1 mapping through pulse sequence optimization and then evaluate the intra-scan repeatability in patients at 3T against investigational modified Look-Locker inversion recovery (MOLLI) T1 mapping. In the first development phase (five human subjects), we implemented and tested centric-pair k-space ordering to suppress image artifacts associated with eddy currents. In the second development phase (15 human subjects), we determined optimal flip angles to reduce the measurement variation in T1 maps. In the validation phase (35 patients), we compared the intra-scan repeatability between investigational MOLLI and optimized AIR. In 23 cardiac planes, conventional centric k-space ordering (3.7%) produced significantly (p T1 , native blood T1 , post-contrast myocardial T1 , post-contrast blood T1 ), flip angles of 55-65° produced lower measurement variation while producing results that are not significantly different from those produced with the previously used flip angle of 35° (p > 0.89, intra-class correlation coefficient ≥ 0.95 for all four measurement types). Compared with investigational MOLLI (coefficient of repeatability, CR = 40.0, 77.2, 26.5, and 25.9 ms for native myocardial, native blood, post-contrast myocardial, and post-contrast blood T1 , and 2.0% for extracellular volume (ECV) measurements, respectively), optimized AIR (CR = 54.3, 89.7, 30.5, and 14.7 ms for native myocardial, native blood, post-contrast myocardial, and post-contrast blood T1 , and 1.6% for ECV measurements, respectively) produced similar absolute intra-scan repeatability in all 35 patients in the validation phase. High repeatability is critically important for longitudinal studies, where the goal is to monitor physiologic/pathologic changes, not measurement variation. Optimized AIR cardiac T1 mapping is likely to yield high scan-retest repeatability for pre-clinical and clinical

  14. Two pulse recoupling

    Science.gov (United States)

    Khaneja, Navin; Kumar, Ashutosh

    2017-08-01

    The paper describes a family of novel recoupling pulse sequences in magic angle spinning (MAS) solid state NMR, called two pulse recoupling. These pulse sequences can be employed for both homonuclear and heteronuclear recoupling experiments and are robust to dispersion in chemical shifts and rf-inhomogeneity. The homonuclear pulse sequence consists of a building block (π)ϕ(π) - ϕ where ϕ =π/4n, and n is number of blocks in a rotor period. The recoupling block is made robust to rf-inhomogeneity by extending it to (π)ϕ(π) - ϕ(π) π + ϕ(π) π - ϕ . The heteronuclear recoupling pulse sequence consists of a building block (π)ϕ1(π)-ϕ1 and (π)ϕ2(π)-ϕ2 on channel I and S, where ϕ1 = 3π/8n, ϕ2 = π/8n and n is number of blocks in a rotor period. The recoupling block is made robust to rf-inhomogeneity by extending it to (π)ϕ1(π)-ϕ1(π) π +ϕ1(π) π -ϕ1 and (π)ϕ2(π)-ϕ2(π) π +ϕ2(π) π -ϕ2 on two channels respectively. The recoupling pulse sequences mix the z magnetization. Experimental quantification of this method is shown for 13Cα-13CO homonuclear recoupling in a sample of Glycine and 15N-13Cα heteronuclear recoupling in Alanine. Application of this method is demonstrated on a sample of tripeptide N-formyl-[U-13C,15N]-Met-Leu-Phe-OH (MLF). Compared to R-sequences (Levitt, 2002), these sequences are more robust to rf-inhomogeneity and give better sensitivity, as shown in Fig. 3.

  15. Optimal MR pulse sequences for hepatic hemangiomas : comparison of T2-weighted turbo-spin-echo, T2-weighted breath-hold turbo-spin-echo, and T1-weighted FLASH dynamic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Wen Chao; Choi, Byung Ihn; Han, Joon Koo; Kim, Tae Kyoung; Cho, Soon Gu [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-03-01

    To optimize MR imaging pulse sequences in the imaging of hepatic hemangioma and to evaluate on dynamic MR imaging the enhancing characteristics of the lesions. Twenty patients with 35 hemangiomas were studied by using Turbo-spin-echo (TSE) sequence (T2-weighted, T2- and heavily T2-weighted breath-hold) and T1-weighted FLASH imaging acquired before, immediately on, and 1, 3 and 5 minutes after injection of a bolus of Gd-DTPA (0.1mmol/kg). Phased-array multicoil was employed. Images were quantitatively analyzed for lesion-to-liver signal difference to noise ratios (SD/Ns), and lesion-to-liver signal ratios (H/Ls), and qualitatively analyzed for lesion conspicuity. The enhancing characteristics of the hemangiomas were described by measuring the change of signal intensity as a curve in T1-weighted FLASH dynamic imaging. For T2-weighted images, breath-hold T2-weighted TSE had a slightly higher SD/N than other pulse sequences, but there was no statistical difference in three fast pulse sequences (p=0.211). For lesion conspicuity, heavily T2-weighted breath-hold TSE images was superior to T2-weighted breath-hold or non-breath-hold TSE (H/L, 5.75, 3.81, 2.87, respectively, p<0.05). T2-weighted breath-hold TSE imaging was more effective than T2-weighted TSE imaging in removing lesion blurring or lack of sharpness, and there was a 12-fold decrease in acquisition time (20sec versus 245 sec). T1-weighted FLASH dynamic images of normal liver showed peak enhancement at less than 1 minute, and of hemangioma at more than 3 minutes;the degree of enhancement for hemangioma decreased after a 3 minute delay. T2-weighed breath-hold TSE imaging and Gd-DTPA enhanced FLASH dynamic imaging with 5 minutes delay are sufficient for imaging hepatic hemangiomas.

  16. Pseudo-random mating populations. In celebration of the 80th anniversary of the Hardy-Weinberg law.

    Science.gov (United States)

    Li, C C

    1988-07-01

    That random mating leads to Hardy-Weinberg distribution of genotypes is well known. This report is to show that, if the deviations from random mating are of a certain pattern, the offspring generation will also be in Hardy-Weinberg proportions. This brings out the fact that random mating is a sufficient condition, not a necessary one, for the attainment of the Hardy-Weinberg proportions. Such nonrandom-mating populations are tentatively said to be pseudo-random mating. Pseudo-random-mating populations exist for both autosomal and sex-linked systems with two or multiple alleles. This report covers the basic case of a two-allele autosomal locus in detail, but the possible extension to two loci and cytonuclear systems have also been mentioned in discussion.

  17. Binary pseudo-random grating as a standard test surface formeasurement of modulation transfer function of interferometricmicroscopes

    Energy Technology Data Exchange (ETDEWEB)

    Yashchuk, Valeriy V.; McKinney, Wayne R.; Takacs, Peter Z.

    2007-07-25

    The task of designing high performance X-ray optical systemsrequires the development of sophisticated X-ray scattering calculationsbased on rigorous information about the optics. One of the mostinsightful approaches to these calculations is based on the powerspectral density (PSD) distribution of the surface height. The majorproblem of measurement of a PSD distribution with an interferometricand/or atomic force microscope arises due to the unknown ModulationTransfer Function (MTF) of the instruments. The MTF characterizes theperturbation of the PSD distribution at higher spatial frequencies. Here,we describe a new method and dedicated test surfaces for calibration ofthe MTF of a microscope. The method is based on use of a speciallydesigned Binary Pseudo-random (BPR) grating. Comparison of atheoretically calculated PSD spectrum of a BPR grating with a spectrummeasured with the grating provides the desired calibration of theinstrumental MTF. The theoretical background of the method, as well asresults of experimental investigations are presented.

  18. Pulse on Pulse

    DEFF Research Database (Denmark)

    Schmidt, Ulrik; Carlson, Merete

    2012-01-01

    of the visitor’s beating heart to the blink of a fragile light bulb, thereby transforming each light bulb into a register of individual life. But at the same time the blinking light bulbs together produce a chaotically flickering light environment composed by various layers of repetitive rhythms, a vibrant...... and pulsating ‘room’. Hence, the visitors in Pulse Room are invited into a complex scenario that continuously oscillates between various aspects of signification (the light bulbs representing individual lives; the pulse itself as the symbolic ‘rhythm of life’) and instants of pure material processuality...... (flickering light bulbs; polyrhythmic layers). Taking our point of departure in a discussion of Gilles Deleuze’s concepts of modulation and signaletic material in relation to electronic media, we examine how the complex orchestration of pulsation between signification and material modulation produces...

  19. [Evaluation of the right internal iliac artery which is anastomosed to transplant renal artery using non-contrast enhanced MR angiography with electrocardiography-gated and 3D True SSFP time-spatial labeling inversion pulse sequence].

    Science.gov (United States)

    Yoshida, Ayako; Shiratori, Yoko; Suzuki, Makoto; Ozasa, Masaya; Takeyama, Mamoru; Eshima, Mitsuhiro; Shinohara, Maiko; Yamamoto, Takao; Tajima, Tsuyoshi

    2015-05-01

    To evaluate whether electrocardiography-gated is useful in non-contrast-enhanced MRA with time-spatial labeling inversion pulse (Time-SLIP) in renal transplantation patients compared with respiration-triggered free-breathing. Simulation-based analyses of black blood time interval (BBTI) values for spatial selective inversion-recovery pulse and electrocardiography rates were performed, and confirmed on human subjects using a three-dimensional (3D) coherent steady-state free precession (SSFP) sequence on a 1.5 tesla Toshiba MRI scanner. Signal acquisition interval and BBTI values in which signal of a water tissue becomes the null point showed a strong correlation, and successfully suppressed signals from the background and provided better contrast between the arteries and the background. Because electrocardiography-gated non-contrast MRA does not depend on the respiration interval, providing a contrast stable, it was suggested to be an effective screening tool for evaluation of pelvic arteries.

  20. Pseudo-Random Modulation of a Laser Diode for Generating Ultrasonic Longitudinal Waves

    Science.gov (United States)

    Madaras, Eric I.; Anatasi, Robert F.

    2004-01-01

    Laser generated ultrasound systems have historically been more complicated and expensive than conventional piezoelectric based systems, and this fact has relegated the acceptance of laser based systems to niche applications for which piezoelectric based systems are less suitable. Lowering system costs, while improving throughput, increasing ultrasound signal levels, and improving signal-to-noise are goals which will help increase the general acceptance of laser based ultrasound. One current limitation with conventional laser generated ultrasound is a material s damage threshold limit. Increasing the optical power to generate more signal eventually damages the material being tested due to rapid, high heating. Generation limitations for laser based ultrasound suggests the use of pulse modulation techniques as an alternate generation method. Pulse modulation techniques can spread the laser energy over time or space, thus reducing laser power densities and minimizing damage. Previous experiments by various organizations using spatial or temporal pulse modulation have been shown to generate detectable surface, plate, and bulk ultrasonic waves with narrow frequency bandwidths . Using narrow frequency bandwidths improved signal detectability, but required the use of expensive and powerful lasers and opto-electronic systems. The use of a laser diode to generate ultrasound is attractive because of its low cost, small size, light weight, simple optics and modulation capability. The use of pulse compression techniques should allow certain types of laser diodes to produce usable ultrasonic signals. The method also does not need to be limited to narrow frequency bandwidths. The method demonstrated here uses a low power laser diode (approximately 150 mW) that is modulated by controlling the diode s drive current and the resulting signal is recovered by cross correlation. A potential application for this system which is briefly demonstrated is in detecting signals in thick

  1. Use of new turbo spin-echo pulse sequences with and without fat suppression in diagnosis and staging of prostate carcinoma; Anwendung neuer Turbo-Spin-Echo-Pulssequenzen mit und ohne Fettunterdrueckung bei der Diagnostik und Stadieneinteilung des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Engelhard, K. [Krankenhaus Martha-Maria, Nuernberg (Germany). Roentgenabteilung; Hollenbach, H.P. [Siemens Erlangen (Germany). Unternehmungsbereich Medizinische Technik; Rieger, J. [Medizinische Klinik Waldkrankenhaus St. Marien, Erlangen (Germany); Kiefer, B. [Siemens Erlangen (Germany). Unternehmungsbereich Medizinische Technik; Riedl, C. [Erlangen-Nuenberg Univ. (Germany). Urologische Klinik; Kreckel, M. [Erlangen-Nuenberg Univ. (Germany). Urologische Klinik; Schrott, K.M. [Erlangen-Nuenberg Univ. (Germany). Urologische Klinik

    1994-01-01

    MR studies using turbo-spin-echo pulse sequences (TSE) were performed on 27 patients with histologically confirmed prostate cancer. A prospective study was conducted in 15 patients who underwent radical prostatectomy. Turbo SE pulse sequences generate strongly T{sub 2}-weighted images of excellent quality with reduction of measurement time by a factor of 4-6. A comparison with standard T{sub 2}-weighted spin-echo pulse sequences indicated on objective improvement in the contrast of pathological structures (p<0.001). With respect to differentiation of stages T{sub 2} and T{sub 3} (TNM) during pathohistological correlation, sensitivity of 80%, specificity of 40% and an accuracy rate of 67% were obtained. Sensitivity of 71% and specificity of 75% were obtained when decuding cases of infiltration into the seminal vesicles, with an accuracy rate of 73%. (orig.) [Deutsch] Bei 27 Patienten mit histologisch gesichertem Prostatakarzinom wurden MRT-Untersuchungen mit Turbo-Spin-Echo-Pulssequencen (TSE) durchgefuehrt. In 15 Faellen erfolgte eine radikale Prostatektomie. TurboSE-Pulssequenzen erzeugen stark T{sub 2}-gewichtete Bilder mit ausgezeichneter Bildqualitaet bei einer Messzeitverkuerzung in einem Bereich von 4-6. Der Vergleich mit einer Standard-T{sub 2}-gewichteten Spin-Echo-Pulssequenz erbrachte eine objektive Kontrastverbesserung (p<0,001). Bei der pathohistologischen Korrelation konnten bei der Differenzierung zwischen Stadium T{sub 2} und T{sub 3} (TNM) eine Sensitivitaet von 80%, eine Spezifitaet von 40% und eine Treffsicherheit von 67% erreicht werden. Eine Sensitivitaet von 71% und eine Spezifitaet von 75% wurden bei der Beurteilung eines Samenblasenbefalls ermittelt, bei einer Treffsicherheit von 73%. (orig.)

  2. Digital pulse compression and its application in reducing radar interference

    Science.gov (United States)

    Blanchette, Martin

    1992-07-01

    Pulse compression is a technique which allows improvement in detecting radar targets while preserving a good resolution power at a distance. This technique consists in transmitting a longer coded pulse and receiving it with a filter adapted to the code transmitted. Digital systems of pulse compression can possess a wider variety of codes than analog systems and can use a new code at each transmission. These two advantages are combined to reduce radar noise. The performance of digital pulse compression is evaluated for different types of radar interference. To counter certain types of interference such as replication of code, it is necessary to use a new code at each transmission. Two types of codes are studied: biphase pseudorandom codes and polyphase codes derived from linear frequency modulated signals or chirp. Supplementary methods, such as cumulative detection and coherent integration of a salvo of pulses, are sometimes needed to supress interference residuals. Digital pulse compression was also applied in real time and the results are supported by computer simulations and by tests on an experimental prototype.

  3. Prefire identification for pulse power systems

    Energy Technology Data Exchange (ETDEWEB)

    Longmire, Jerry L. (Los Alamos, NM); Thuot, Michael E. (Espanola, NM); Warren, David S. (Los Alamos, NM)

    1985-01-01

    Prefires in a high-power, high-frequency, multi-stage pulse generator are detected by a system having an EMI shielded pulse timing transmitter associated with and tailored to each stage of the pulse generator. Each pulse timing transmitter upon detection of a pulse triggers a laser diode to send an optical signal through a high frequency fiber optic cable to a pulse timing receiver which converts the optical signal to an electrical pulse. The electrical pulses from all pulse timing receivers are fed through an OR circuit to start a time interval measuring device and each electrical pulse is used to stop an individual channel in the measuring device thereby recording the firing sequence of the multi-stage pulse generator.

  4. Prefire identification for pulse power systems

    Energy Technology Data Exchange (ETDEWEB)

    Longmire, J. L.; Thuot, M. E.; Warren, D. S.

    1985-04-09

    Prefires in a high-power, high-frequency, multi-stage pulse generator are detected by a system having an EMI shielded pulse timing transmitter associated with and tailored to each stage of the pulse generator. Each pulse timing transmitter upon detection of a pulse triggers a laser diode to send an optical signal through a high frequency fiber optic cable to a pulse timing receiver which converts the optical signal to an electrical pulse. The electrical pulses from all pulse timing receivers are fed through an OR circuit to start a time interval measuring device and each electrical pulse is used to stop an individual channel in the measuring device thereby recording the firing sequence of the multi-stage pulse generator.

  5. Prefire identification for pulse-power systems

    Energy Technology Data Exchange (ETDEWEB)

    Longmire, J.L.; Thuot, M.E.; Warren, D.S.

    1982-08-23

    Prefires in a high-power, high-frequency, multi-stage pulse generator are detected by a system having an EMI shielded pulse timing transmitter associated with and tailored to each stage of the pulse generator. Each pulse timing transmitter upon detection of a pulse triggers a laser diode to send an optical signal through a high frequency fiber optic cable to a pulse timing receiver which converts the optical signal to an electrical pulse. The electrical pulses from all pulse timing receivers are fed through an OR circuit to start a time interval measuring device and each electrical pulse is used to stop an individual channel in the measuring device thereby recording the firing sequence of the multi-stage pulse generator.

  6. Stability of modulation transfer function calibration of surface profilometers using binary pseudo-random gratings and arrays with nonideal groove shapes

    Energy Technology Data Exchange (ETDEWEB)

    Barber, Samuel K.; Anderson, Erik H.; Cambie, Rossana; Marchesini, Stefano; McKinney, Wayne R.; Takacs, Peter Z.; Voronov, Dmitry L.; Yashchuk, Valeriy V.

    2010-03-31

    The major problem of measurement of a power spectral density (PSD) distribution of surface heights with surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments, which tends to distort the PSD at higher spatial frequencies. The special mathematical properties of binary pseudo-random patterns make them an ideal basis for developing MTF calibration test surfaces. Two-dimensional binary pseudo-random arrays (BPRAs) have been fabricated and used for the MTF calibration of the MicroMap{trademark}-570 interferometric microscope with all available objectives. An investigation into the effects of fabrication imperfections on the quality of the MTF calibration and a procedure for accounting for such imperfections are presented.

  7. Fully digital jerk-based chaotic oscillators for high throughput pseudo-random number generators up to 8.77Gbits/s

    KAUST Repository

    Mansingka, Abhinav S.

    2014-06-18

    This paper introduces fully digital implementations of four di erent systems in the 3rd order jerk-equation based chaotic family using the Euler approximation. The digitization approach enables controllable chaotic systems that reliably provide sinusoidal or chaotic output based on a selection input. New systems are introduced, derived using logical and arithmetic operations between two system implementations of different bus widths, with up to 100x higher maximum Lyapunov exponent than the original jerkequation based chaotic systems. The resulting chaotic output is shown to pass the NIST sp. 800-22 statistical test suite for pseudorandom number generators without post-processing by only eliminating the statistically defective bits. The systems are designed in Verilog HDL and experimentally verified on a Xilinx Virtex 4 FPGA for a maximum throughput of 15.59 Gbits/s for the native chaotic output and 8.77 Gbits/s for the resulting pseudo-random number generators.

  8. The Methods of Implementation of the Three-dimensional Pseudorandom Number Generator DOZEN for Heterogeneous CPU/GPU /FPGA High-performance Systems

    Directory of Open Access Journals (Sweden)

    Nikolay Petrovich Vasilyev

    2015-03-01

    Full Text Available The paper describes the scope of information security protocols based on PRN G in industrial systems. A method for implementing three-dimensional pseudorandom number generator D O Z E N in hybrid systems is provided. The description and results of studies parallel CUDA-version of the algorithm for use in hybrid data centers and high-performance FPGA-version for use in hardware solutions in controlled facilities of SCADA-systems are given.

  9. Distribution of some sequences of points on elliptic curves

    DEFF Research Database (Denmark)

    Lange, Tanja; Shparlinski, Igor

    2007-01-01

    We estimate character sums over points on elliptic curves over a finite field of q elements. Pseudorandom sequences can be constructed by taking linear combinations with small coefficients (for example, from the set {−1, 0, 1}) of a fixed vector of points, which forms the seed of the generator. We...... consider several particular cases of this general approach which are of special practical interest and have occurred in the literature. For each of them we show that the resulting sequence has good uniformity of distribution properties....

  10. Cross-utilizing hyperchaotic and DNA sequences for image encryption

    Science.gov (United States)

    Zhan, Kun; Wei, Dong; Shi, Jinhui; Yu, Jun

    2017-01-01

    The hyperchaotic sequence and the DNA sequence are utilized jointly for image encryption. A four-dimensional hyperchaotic system is used to generate a pseudorandom sequence. The main idea is to apply the hyperchaotic sequence to almost all steps of the encryption. All intensity values of an input image are converted to a serial binary digit stream, and the bitstream is scrambled globally by the hyperchaotic sequence. DNA algebraic operation and complementation are performed between the hyperchaotic sequence and the DNA sequence to obtain a robust encryption performance. The experiment results demonstrate that the encryption algorithm achieves the performance of the state-of-the-art methods in term of quality, security, and robustness against noise and cropping attack.

  11. BINERY PSEUDO-RANDOM GRATING AS A STANDARD TEST SURFACE FOR MEASUREMENT OF MODULATION TRANSFER FUNCTION OF INTERFEROMETRIC MICROSCOPES.

    Energy Technology Data Exchange (ETDEWEB)

    YASHCHUK,V.V.; MCKINNEY, W.R.; TAKACS, P.Z.

    2007-08-01

    The task of designing high performance X-ray optical systems requires the development of sophisticated X-ray scattering calculations based on rigorous information about the optics. One of the most insightful approaches to these calculations is based on the power spectral density (PSD) distribution of the surface height. The major problem of measurement of a PSD distribution with an interferometric and/or atomic force microscope arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF characterizes the perturbation of the PSD distribution at higher spatial frequencies. Here, we describe a new method and dedicated test surfaces for calibration of the MTF of a microscope. The method is based on use of a specially designed Binary Pseudo-random (BPR) grating. Comparison of a theoretically calculated PSD spectrum of a BPR grating with a spectrum measured with the grating provides the desired calibration of the instrumental MTF. The theoretical background of the method, as well as results of experimental investigations are presented.

  12. A cubic map chaos criterion theorem with applications in generalized synchronization based pseudorandom number generator and image encryption

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Xiuping, E-mail: yangxiuping-1990@163.com; Min, Lequan, E-mail: minlequan@sina.com; Wang, Xue, E-mail: wangxue-20130818@163.com [Schools of Mathematics and Physics, University of Science and Technology Beijing, Beijing 100083 (China)

    2015-05-15

    This paper sets up a chaos criterion theorem on a kind of cubic polynomial discrete maps. Using this theorem, Zhou-Song's chaos criterion theorem on quadratic polynomial discrete maps and generalized synchronization (GS) theorem construct an eight-dimensional chaotic GS system. Numerical simulations have been carried out to verify the effectiveness of theoretical results. The chaotic GS system is used to design a chaos-based pseudorandom number generator (CPRNG). Using FIPS 140-2 test suit/Generalized FIPS 140-2, test suit tests the randomness of two 1000 key streams consisting of 20 000 bits generated by the CPRNG, respectively. The results show that there are 99.9%/98.5% key streams to have passed the FIPS 140-2 test suit/Generalized FIPS 140-2 test. Numerical simulations show that the different keystreams have an average 50.001% same codes. The key space of the CPRNG is larger than 2{sup 1345}. As an application of the CPRNG, this study gives an image encryption example. Experimental results show that the linear coefficients between the plaintext and the ciphertext and the decrypted ciphertexts via the 100 key streams with perturbed keys are less than 0.00428. The result suggests that the decrypted texts via the keystreams generated via perturbed keys of the CPRNG are almost completely independent on the original image text, and brute attacks are needed to break the cryptographic system.

  13. Code length limit in phase-sensitive OTDR using ultralong (>1M bits) pulse sequences due to fading induced by fiber optical path drifts

    Science.gov (United States)

    Martins, H. F.; Shi, K.; Thomsen, B. C.; Martin-Lopez, S.; Gonzalez-Herraez, M.; Savory, S. J.

    2017-04-01

    Recently, it has been demonstrated that by recovering the amplitude and phase of the backscattered optical signal, a ΦOTDR using pulse coding can be treated as a fully linear system in terms of trace coding/decoding, thus allowing for the use of tens of thousands of bits with a dramatic improvement of the system performance. In this communication, as a continuation of previous work by the same authors, a preliminary study aiming at characterizing the limits of the system in terms of maximum usable code length is presented. Using a code exceeding 1million bits over a duration of 0.26ms, it is observed that fiber optical path variations exceeding ≍π occurring over a time inferior to the pulse code length can lead to localized fading in the ΦOTDR trace. The occurrence, positions and form of the fading points along the ΦOTDR trace is observed to be strongly dependent on the type, frequency and amplitude of the perturbations applied to the fiber.

  14. Multilocus sequence typing, pulsed-field gel electrophoresis, and fla short variable region typing of clonal complexes of Campylobacter jejuni strains of human, bovine, and poultry origins in Luxembourg.

    Science.gov (United States)

    Ragimbeau, Catherine; Schneider, François; Losch, Serge; Even, Jos; Mossong, Joël

    2008-12-01

    Campylobacter jejuni is the most common cause of bacterial gastroenteritis in Luxembourg, with a marked seasonal peak during summer. The majority of these infections are thought to be sporadic, and the relative contribution of potential sources and reservoirs is still poorly understood. We monitored human cases from June to September 2006 (n = 124) by molecular characterization of isolates with the aim of rapidly detecting temporally related cases. In addition, isolates from poultry meat (n = 36) and cattle cecal contents (n = 48) were genotyped for comparison and identification of common clusters between veterinary and human C. jejuni populations. A total of 208 isolates were typed by sequencing the fla short variable region, macrorestriction analysis resolved by pulsed-field gel electrophoresis (PFGE), and multilocus sequence typing (MLST). We observed a high diversity of human strains during a given summer season. Poultry and human isolates had a higher diversity of sequence types than isolates of bovine origin, for which clonal complexes CC21 (41.6%) and CC61 (18.7%) were predominant. CC21 was also the most common complex found among human isolates (21.8%). The substantial concordance between PFGE and MLST results for this last group of strains suggests that they are clonally related. Our study indicates that while poultry remains an important source, cattle could be an underestimated reservoir of human C. jejuni cases. Transmission mechanisms of cattle-specific strains warrant further investigation.

  15. Cost-effectiveness of multidisciplinary wound care in nursing homes: a pseudo-randomized pragmatic cluster trial.

    Science.gov (United States)

    Vu, Trang; Harris, Anthony; Duncan, Gregg; Sussman, Geoff

    2007-09-01

    To evaluate the cost-effectiveness of a multidisciplinary wound care team in the nursing home setting from a health system perspective. Pseudo-randomized pragmatic cluster trial with 20-week follow-up involving 342 uncomplicated leg and pressure ulcers in 176 residents located in 44 high-care nursing homes in Melbourne, Australia in 1999-2000. Twenty-one nursing homes (180 wounds in 94 residents) were assigned to the intervention arm and 23 to the control arm (162 wounds in 82 residents). Residents in the intervention arm received standardized treatment from a wound care team comprising of trained community pharmacists and nurses. Residents in the control arm received usual care. More wounds healed during the trial in the intervention arm than in the control arm (61.7% versus 52.5%, P = 0.07). A Cox regression with shared frailty predicted that the chances of healing increased 73% for intervention wounds [95% confidence interval (CI) 20-150%, P = 0.003]. The mean treatment cost was $A616.4 for intervention and $A977.9 for control patients (P = 0.006). Most cost reduction was obtained from decreases in nursing time and waste disposal. The mean cost saving per wound, adjusted for baseline wound severity and random censoring, was $A277.9 (95% CI $A21.6-$A534.1). Standardized treatment provided by a multidisciplinary wound care team saved costs and improved chronic wound healing in nursing homes. The main source of saving was in the cost of nursing time in applying traditional dressings and in the cost of their disposal.

  16. Intracranial cerebrospinal fluid spaces imaging using a pulse-triggered three-dimensional turbo spin echo MR sequence with variable flip-angle distribution

    Energy Technology Data Exchange (ETDEWEB)

    Hodel, Jerome [Unite Analyse et Restauration du Mouvement, UMR-CNRS, 8005 LBM ParisTech Ensam, Paris (France); University Paris Est Creteil (UPEC), Creteil (France); Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Henri Mondor, Department of Neuroradiology, Creteil (France); Hopital Henri Mondor, Creteil (France); Silvera, Jonathan [University Paris Est Creteil (UPEC), Creteil (France); Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Henri Mondor, Department of Neuroradiology, Creteil (France); Bekaert, Olivier; Decq, Philippe [Unite Analyse et Restauration du Mouvement, UMR-CNRS, 8005 LBM ParisTech Ensam, Paris (France); University Paris Est Creteil (UPEC), Creteil (France); Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Henri Mondor, Department of Neurosurgery, Creteil (France); Rahmouni, Alain [University Paris Est Creteil (UPEC), Creteil (France); Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Henri Mondor, Department of Radiology, Creteil (France); Bastuji-Garin, Sylvie [University Paris Est Creteil (UPEC), Creteil (France); Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Henri Mondor, Department of Public Health, Creteil (France); Vignaud, Alexandre [Siemens Healthcare, Saint Denis (France); Petit, Eric; Durning, Bruno [Laboratoire Images Signaux et Systemes Intelligents, UPEC, Creteil (France)

    2011-02-15

    To assess the three-dimensional turbo spin echo with variable flip-angle distribution magnetic resonance sequence (SPACE: Sampling Perfection with Application optimised Contrast using different flip-angle Evolution) for the imaging of intracranial cerebrospinal fluid (CSF) spaces. We prospectively investigated 18 healthy volunteers and 25 patients, 20 with communicating hydrocephalus (CH), five with non-communicating hydrocephalus (NCH), using the SPACE sequence at 1.5T. Volume rendering views of both intracranial and ventricular CSF were obtained for all patients and volunteers. The subarachnoid CSF distribution was qualitatively evaluated on volume rendering views using a four-point scale. The CSF volumes within total, ventricular and subarachnoid spaces were calculated as well as the ratio between ventricular and subarachnoid CSF volumes. Three different patterns of subarachnoid CSF distribution were observed. In healthy volunteers we found narrowed CSF spaces within the occipital aera. A diffuse narrowing of the subarachnoid CSF spaces was observed in patients with NCH whereas patients with CH exhibited narrowed CSF spaces within the high midline convexity. The ratios between ventricular and subarachnoid CSF volumes were significantly different among the volunteers, patients with CH and patients with NCH. The assessment of CSF spaces volume and distribution may help to characterise hydrocephalus. (orig.)

  17. Pulse Oximetry

    Science.gov (United States)

    ... people need more oxygen when asleep than when awake. Some need more oxygen with activity than when ... oxygen saturation levels (below 80%) or with very dark skin. When should I use a pulse oximeter? ...

  18. Comparison of tool feed influence in CNC polishing between a novel circular-random path and other pseudo-random paths.

    Science.gov (United States)

    Takizawa, Ken; Beaucamp, Anthony

    2017-09-18

    A new category of circular pseudo-random paths is proposed in order to suppress repetitive patterns and improve surface waviness on ultra-precision polished surfaces. Random paths in prior research had many corners, therefore deceleration of the polishing tool affected the surface waviness. The new random path can suppress velocity changes of the polishing tool and thus restrict degradation of the surface waviness, making it suitable for applications with stringent mid-spatial-frequency requirements such as photomask blanks for EUV lithography.

  19. Choice of the pulse sequence and parameters for improved signal-to-noise ratio in T1-weighted study of MRI.

    Science.gov (United States)

    Amin, Naima; Afzal, Muhammad; Yousaf, Muhammad; Javid, Muhammad Arshad

    2015-05-01

    To investigate the practical impact of alteration of imaging parameters on signal-to-noise ratio for the most commonly used T1-weighted magnetic resonance sequences. The study was conducted in the Department of Medical Physics, Ninewells Hospital and Medical School, Dundee, UK, in 2007. Magnetic resonance images of a tissue-equivalent material were generated with a set of T1 and T2 values. Experimental variations in the imaging parameters were performed in echo time and repetition time. Quantitative analysis consisted of signal-to-noise ratio. Percentage inaccuracy in signal-to-noise ratio was the result of inappropriate choice of parameters. We have investigated conventional spin echo, fast spin echo and fast fluid attenuated inversion recovery with one of corresponding percentage errors 28.68%, -36.65% and -40.34%, respectively. Conventional spin echo presented moderately low percentage error with the choice of repetition time and echo time. Factual error in fast spin echo was slightly higher than conventional spin echo. Fast fluid attenuated inversion recovery could create outstanding signal-to-noise ratio of high T1/T2 value phantoms in T1-weighted images. The role of repetition time and echo time in T1-weighted images was crucial to sustain the image quality.

  20. [Use of multilocus sequence typing and pulsed-field gel electrophoresis for the study of serogroup B Neisseria meningitidis isolates from Casablanca (Morocco)].

    Science.gov (United States)

    Zerouali, K; Castelli, P; Van Looveren, M; El Mdaghri, N; Boudouma, M; Benbachir, M; Nicolas, P

    2006-04-01

    A previous study showed that B:4:P1.15 was the most frequent phenotype of Neisseria meningitidis isolated in Casablanca (Morocco). To determine if there was an epidemic clone, MLST and PFGE were used to compare 13 B:4:P1.15 strains isolated from September 1999 to December 2000. MLST showed 4 Sequence Types (ST): ST-33 was the most frequent ST (9/13 strains) and 4 strains belonged to 3 newly described STs. Twelve stains belonged to ST-32 complex, and one strain presenting a new ST (ST-2502) did not belong to any known ST complex. The analysis by PFGE showed that the strains were subdivided into 7 clusters, and that there was no epidemic clone. MLST is useful for long-term epidemiological studies on N. meningitidis strains from varied geographical origins. PFGE seemed to be well adapted to the comparison of a small number of strains isolated during a short period within a defined community.

  1. Pulse-to-pulse intensity modulation and drifting subpulses in recycled pulsars

    OpenAIRE

    Edwards, R; Stappers, B. W.

    2003-01-01

    We report the detection of pulse-to-pulse periodic intensity modulations, in observations of recycled pulsars. Even though the detection of individual pulses was generally not possible due to their low flux density and short duration, through the accumulation of statistics over sequences of 10^5--10^6 pulses we were able to determine the presence and properties of the pulse-to-pulse intensity variations of six pulsars. In most cases we found that the modulation included a weak, broadly quasi-...

  2. Treatment Pulse Application for Magnetic Stimulation

    Directory of Open Access Journals (Sweden)

    Sun-Seob Choi

    2011-01-01

    Full Text Available Treatment and diagnosis can be made in difficult areas simply by changing the output pulse form of the magnetic stimulation device. However, there is a limitation in the range of treatments and diagnoses of a conventional sinusoidal stimulation treatment pulse because the intensity, width, and form of the pulse must be changed according to the lesion type. This paper reports a multidischarge method, where the stimulation coils were driven in sequence via multiple switching control. The limitation of the existing simple sinusoidal pulse form could be overcome by changing the intensity, width, and form of the pulse. In this study, a new sequential discharge method was proposed to freely alter the pulse width. The output characteristics of the stimulation treatment pulse were examined according to the trigger signal delay applied to the switch at each stage by applying a range of superposition pulses to the magnetic simulation device, which is widely used in industry and medicine.

  3. Pulse plating

    CERN Document Server

    Hansal, Wolfgang E G; Green, Todd; Leisner, Peter; Reichenbach, Andreas

    2012-01-01

    The electrodeposition of metals using pulsed current has achieved practical importance in recent years. Although it has long been known that changes in potential, with or without polarity reversal, can significantly affect the deposition process, the practical application of this has been slow to be adopted. This can largely be explained in terms of the complex relationship between the current regime and its effect on the electrodeposition process. In order to harness these effects, an understanding of the anodic and cathodic electrochemical processes is necessary, together with the effects of polarity reversal and the rate of such reversals. In this new monograph, the basics of metal electrodeposition from solution are laid out in great detail in seven distinct chapters. With this knowledge, the reader is able to predict how a given pulse train profile can be adopted to achieve a desired outcome. Equally important is the choice of a suitable rectifier and the ancillary control circuits to enable pulse platin...

  4. Expanding Pseudorandom Functions

    DEFF Research Database (Denmark)

    Damgård, Ivan Bjerre; Nielsen, Jesper Buus

    2002-01-01

    used) encryption modes as CBC mode and counter (CTR) mode, but is provably secure against chosen-plaintext attack (CPA) already if the underlying symmetric cipher is secure against known-plaintext attack (KPA). We prove that CBC, CTR and Jutla’s integrity aware modes do not have this property....... In particular, we prove that when using a KPA secure block cipher, then: CBC mode is KPA secure, but need not be CPA secure, Jutla’s modes need not be CPA secure, and CTR mode need not be even KPA secure. The analysis is done in a concrete security framework....

  5. PRIMITIVE MATRICES AND GENERATORS OF PSEUDO RANDOM SEQUENCES OF GALOIS

    Directory of Open Access Journals (Sweden)

    A. Beletsky

    2014-04-01

    Full Text Available In theory and practice of information cryptographic protection one of the key problems is the forming a binary pseudo-random sequences (PRS with a maximum length with acceptable statistical characteristics. PRS generators are usually implemented by linear shift register (LSR of maximum period with linear feedback [1]. In this paper we extend the concept of LSR, assuming that each of its rank (memory cell can be in one of the following condition. Let’s call such registers “generalized linear shift register.” The research goal is to develop algorithms for constructing Galois and Fibonacci generalized matrix of n-order over the field , which uniquely determined both the structure of corresponding generalized of n-order LSR maximal period, and formed on their basis Galois PRS generators of maximum length. Thus the article presents the questions of formation the primitive generalized Fibonacci and Galois arbitrary order matrix over the prime field . The synthesis of matrices is based on the use of irreducible polynomials of degree and primitive elements of the extended field generated by polynomial. The constructing methods of Galois and Fibonacci conjugated primitive matrices are suggested. The using possibilities of such matrices in solving the problem of constructing generalized generators of Galois pseudo-random sequences are discussed.

  6. Nonparametric estimation of ultrasound pulses

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Leeman, Sidney

    1994-01-01

    An algorithm for nonparametric estimation of 1D ultrasound pulses in echo sequences from human tissues is derived. The technique is a variation of the homomorphic filtering technique using the real cepstrum, and the underlying basis of the method is explained. The algorithm exploits a priori...

  7. A novel programmable pulse generator with nanosecond resolution for pulsed electron paramagnetic resonance applications.

    Science.gov (United States)

    Devasahayam, N; Subramanian, S; Krishna, M C

    2008-02-01

    A pulse programmer with nanosecond time resolution needed for time-domain electron paramagnetic resonance (EPR) spectroscopic applications is described. This unit uses commercially available timing and input-output port modules and control software developed in our laboratory. The pulse programmer is operated through a personal computer front panel graphic user interface (GUI) inputs to control pulse widths, delays, and the associated acquisition trigger timings. Based on these parameters, all other associated gate and trigger timings are internally generated automatically without the need to enter them explicitly. The excitation pulse widths were of nanosecond resolution while all other gate pulses can be incremented in steps of 20 ns without compromising spectrometer performance. In the current configuration, the pulse programmer permits generation of a single pulse or multiple pulse sequences for EPR imaging with minimal data entry via the front panel GUI.

  8. A Stream Encryption Scheme with Both Key and Plaintext Avalanche Effects for Designing Chaos-Based Pseudorandom Number Generator with Application to Image Encryption

    Science.gov (United States)

    Han, Dandan; Min, Lequan; Chen, Guanrong

    Based on a stream encryption scheme with avalanche effect (SESAE), a stream encryption scheme with both key avalanche effect and plaintext avalanche effect (SESKPAE) is introduced. Using this scheme and an ideal 2d-word (d-segment) pseudorandom number generator (PRNG), a plaintext can be encrypted such that each bit of the ciphertext block has a change with the probable probability of (2d - 1)/2d when any word of the key is changed or any bit of the plaintext is changed. To that end, a novel four-dimensional discrete chaotic system (4DDCS) is proposed. Combining the 4DDCS with a generalized synchronization (GS) theorem, a novel eight-dimensional discrete GS chaotic system (8DDGSCS) is constructed. Using the 8DDGSCS, a 216-word chaotic pseudorandom number generator (CPRNG) is designed. The keyspace of the 216-word CPRNG is larger than 21195. Then, the FIPS 140-2 test suit/generalized FIPS 140-2 test suit is used to test the randomness of the 1000-key streams consisting of 20000 bits generated by the 216-word CPRNG, the RC4 algorithm PRNG and the ZUC algorithm PRNG, respectively. The test results show that for the three PRNGs, there are 100%/98.9%, 99.9%/98.8%, 100%/97.9% key streams passing the tests, respectively. Furthermore, the SP800-22 test suite is used to test the randomness of four 100-key streams consisting of 1000000 bits generated by four PRNGs, respectively. The numerical results show that the randomness performances of the 216-word CPRNG is promising, showing that there are no significant correlations between the key streams and the perturbed key streams generated via the 216-word CPRNG. Finally, using the 216-word CPRNG and the SESKPAE to encrypt two gray-scale images, test results demonstrate that the 216-word CPRNG is able to generate both key avalanche effect and plaintext avalanche effect, which are similar to those generated via an ideal CPRNG, and performs better than other comparable schemes.

  9. Ablation of steel by microsecond pulse trains

    Science.gov (United States)

    Windeler, Matthew Karl Ross

    Laser micromachining is an important material processing technique used in industry and medicine to produce parts with high precision. Control of the material removal process is imperative to obtain the desired part with minimal thermal damage to the surrounding material. Longer pulsed lasers, with pulse durations of milli- and microseconds, are used primarily for laser through-cutting and welding. In this work, a two-pulse sequence using microsecond pulse durations is demonstrated to achieve consistent material removal during percussion drilling when the delay between the pulses is properly defined. The light-matter interaction moves from a regime of surface morphology changes to melt and vapour ejection. Inline coherent imaging (ICI), a broadband, spatially-coherent imaging technique, is used to monitor the ablation process. The pulse parameter space is explored and the key regimes are determined. Material removal is observed when the pulse delay is on the order of the pulse duration. ICI is also used to directly observe the ablation process. Melt dynamics are characterized by monitoring surface changes during and after laser processing at several positions in and around the interaction region. Ablation is enhanced when the melt has time to flow back into the hole before the interaction with the second pulse begins. A phenomenological model is developed to understand the relationship between material removal and pulse delay. Based on melt refilling the interaction region, described by logistic growth, and heat loss, described by exponential decay, the model is fit to several datasets. The fit parameters reflect the pulse energies and durations used in the ablation experiments. For pulse durations of 50 us with pulse energies of 7.32 mJ +/- 0.09 mJ, the logisitic growth component of the model reaches half maximum after 8.3 mus +/- 1.1 us and the exponential decays with a rate of 64 mus +/- 15 us. The phenomenological model offers an interpretation of the material

  10. Microscopic Displacement Imaging with Pulsed Field Gradient Turbo Spin-Echo NMR

    NARCIS (Netherlands)

    Scheenen, T.W.J.; Dusschoten, van D.; Jager, de P.A.; As, van H.

    2000-01-01

    We present a pulse sequence that enables the accurate and spatially resolved measurements of the displacements of spins in a variety of (biological) systems. The pulse sequence combines pulsed field gradient (PFG) NMR with turbo spin–echo (TSE) imaging. It is shown here that by ensuring that the

  11. A Chaos Robustness Criterion for 2D Piecewise Smooth Map with Applications in Pseudorandom Number Generator and Image Encryption with Avalanche Effect

    Directory of Open Access Journals (Sweden)

    Dandan Han

    2016-01-01

    Full Text Available This study proposes a chaos robustness criterion for a kind of 2D piecewise smooth maps (2DPSMs. Using the chaos robustness criterion, one can easily determine the robust chaos parameter regions for some 2DPSMs. Combining 2DPSM with a generalized synchronization (GS theorem, this study introduces a novel 6-dimensional discrete GS chaotic system. Based on the system, a 216-word chaotic pseudorandom number generator (CPRNG is designed. The key space of the CPRNG is larger than 2996. Using the FIPS 140-2 test suit/generalized FIPS 140-2 test suit tests the randomness of the 1000 key streams consists of 20,000 bits generated by the CPRNG, the RC4 algorithm, and the ZUC algorithm, respectively. The numerical results show that the three algorithms do not have significant differences. The CPRNG and a stream encryption scheme with avalanche effect (SESAE are used to encrypt an image. The results demonstrate that the CPRNG is able to generate the avalanche effects which are similar to those generated via ideal CPRNGs. The SESAE with one-time-pad scheme makes any attackers have to use brute attacks to break our cryptographic system.

  12. The resonant multi-pulse ionization injection

    Science.gov (United States)

    Tomassini, Paolo; De Nicola, Sergio; Labate, Luca; Londrillo, Pasquale; Fedele, Renato; Terzani, Davide; Gizzi, Leonida A.

    2017-10-01

    The production of high-quality electron bunches in Laser Wake Field Acceleration relies on the possibility to inject ultra-low emittance bunches in the plasma wave. In this paper, we present a new bunch injection scheme in which electrons extracted by ionization are trapped by a large-amplitude plasma wave driven by a train of resonant ultrashort pulses. In the Resonant Multi-Pulse Ionization injection scheme, the main portion of a single ultrashort (e.g., Ti:Sa) laser system pulse is temporally shaped as a sequence of resonant sub-pulses, while a minor portion acts as an ionizing pulse. Simulations show that high-quality electron bunches with normalized emittance as low as 0.08 mm × mrad and 0.65% energy spread can be obtained with a single present-day 100TW-class Ti:Sa laser system.

  13. Alignment enhancement of a symmetric top molecule by two short laser pulses

    DEFF Research Database (Denmark)

    Bisgaard, Christer Z; Viftrup, Simon; Stapelfeldt, Henrik

    2006-01-01

    equation. It is shown that the strongest degree of one-dimensional (single axis) field-free alignment obtainable with a single pulse can be enhanced using the two-pulse sequence in a parallel polarization geometry. The conditions for alignment enhancement are: (1) The second pulse must be sent near...... the time where the degree of alignment, due to the first pulse, peaks. (2) The intensity of the first pulse must be smaller than the intensity of the second pulse, the optimal intensity ratio being determined by the duration of the pulses. Numerically, we also discuss the existence of an optimal pulse...

  14. Inductive Pulse Generation

    OpenAIRE

    Lindblom, Adam

    2006-01-01

    Pulsed power generators are a key component in compact systems for generation of high-power microwaves (HPM). HPM generation by virtual cathode devices such as Vircators put high demands on the source. The rise time and the pulse length of the source voltage are two key issues in the generation of HPM radiation. This thesis describes the construction and tests of several inductive high power pulse generators. The pulse generators were designed with the intent to deliver a pulse with fast rise...

  15. Pulsed water jet generated by pulse multiplication

    Czech Academy of Sciences Publication Activity Database

    Dvorský, R.; Sitek, Libor; Sochor, T.

    2016-01-01

    Roč. 23, č. 4 (2016), s. 959-967 ISSN 1330-3651 R&D Projects: GA MŠk(CZ) LO1406; GA MŠk ED2.1.00/03.0082 Institutional support: RVO:68145535 Keywords : high-pressure pulses * pulse intensifier * pulsed water jet * water hammer effect Subject RIV: JQ - Machines ; Tools Impact factor: 0.723, year: 2016 http://hrcak.srce.hr/163752?lang=en

  16. Finite pulse effects in CPMG pulse trains on paramagnetic materials.

    Science.gov (United States)

    Leskes, Michal; Grey, Clare P

    2015-09-14

    The Carr-Purcell-Meiboom-Gill (CPMG) sequence is commonly used in high resolution NMR spectroscopy and in magnetic resonance imaging for the measurement of transverse relaxation in systems that are subject to diffusion in internal or external gradients and is superior to the Hahn echo measurement, which is more sensitive to diffusion effects. Similarly, it can potentially be used to study dynamic processes in electrode materials for lithium ion batteries. Here we compare the (7)Li signal decay curves obtained with the CPMG and Hahn echo sequences under static conditions (i.e., in the absence of magic angle spinning) in paramagnetic materials with varying transition metal ion concentrations. Our results indicate that under CPMG pulse trains the lifetime of the (7)Li signal is substantially extended and is correlated with the strength of the electron-nuclear interaction. Numerical simulations and analytical calculations using Floquet theory suggest that the combination of large interactions and a train of finite pulses, results in a spin locking effect which significantly slows the signal's decay. While these effects complicate the interpretation of CPMG-based investigations of diffusion and chemical exchange in paramagnetic materials, they may provide a useful approach to extend the signal's lifetime in these often fast relaxing systems, enabling the use of correlation experiments. Furthermore, these results highlight the importance of developing a deeper understanding of the effects of the large paramagnetic interactions during multiple pulse experiments in order to extend the experimental arsenal available for static and in situ NMR investigations of paramagnetic materials.

  17. Regular radiation field pulses produced by intracloud lightning discharges

    Science.gov (United States)

    Krider, E. P.; Radda, G. J.; Noggle, R. C.

    1975-01-01

    Sequences or bursts of uniform pulses have been recorded during a large fraction of intracloud lightning discharges in Florida and Arizona. The wave form of a typical pulse begins with a fast large-amplitude portion followed by a small and slowly varying overshoot. The full width and half maximum of the large amplitude peak is typically 0.75 microsec, and the time intervals between pulses are typically 5 microsec in both maritime and continental storms. The pulse shapes and interval times suggest that the source of these pulses in an intracloud dart-stepped leader process similar to that which has been photographed in discharges to ground.

  18. Humans cannot consciously generate random numbers sequences: Polemic study.

    Science.gov (United States)

    Figurska, Małgorzata; Stańczyk, Maciej; Kulesza, Kamil

    2008-01-01

    It is widely believed, that randomness exists in Nature. In fact such an assumption underlies many scientific theories and is embedded in the foundations of quantum mechanics. Assuming that this hypothesis is valid one can use natural phenomena, like radioactive decay, to generate random numbers. Today, computers are capable of generating the so-called pseudorandom numbers. Such series of numbers are only seemingly random (bias in the randomness quality can be observed). Question whether people can produce random numbers, has been investigated by many scientists in the recent years. The paper "Humans can consciously generate random numbers sequences..." published recently in Medical Hypotheses made claims that were in many ways contrary to state of art; it also stated far-reaching hypotheses. So, we decided to repeat the experiments reported, with special care being taken of proper laboratory procedures. Here, we present the results and discuss possible implications in computer and other sciences.

  19. Controllable pulse parameter transcranial magnetic stimulator with enhanced circuit topology and pulse shaping

    Science.gov (United States)

    Peterchev, Angel V.; DʼOstilio, Kevin; Rothwell, John C.; Murphy, David L.

    2014-10-01

    Objective. This work aims at flexible and practical pulse parameter control in transcranial magnetic stimulation (TMS), which is currently very limited in commercial devices. Approach. We present a third generation controllable pulse parameter device (cTMS3) that uses a novel circuit topology with two energy-storage capacitors. It incorporates several implementation and functionality advantages over conventional TMS devices and other devices with advanced pulse shape control. cTMS3 generates lower internal voltage differences and is implemented with transistors with a lower voltage rating than prior cTMS devices. Main results. cTMS3 provides more flexible pulse shaping since the circuit topology allows four coil-voltage levels during a pulse, including approximately zero voltage. The near-zero coil voltage enables snubbing of the ringing at the end of the pulse without the need for a separate active snubber circuit. cTMS3 can generate powerful rapid pulse sequences (\\lt 10 ms inter pulse interval) by increasing the width of each subsequent pulse and utilizing the large capacitor energy storage, allowing the implementation of paradigms such as paired-pulse and quadripulse TMS with a single pulse generation circuit. cTMS3 can also generate theta (50 Hz) burst stimulation with predominantly unidirectional electric field pulses. The cTMS3 device functionality and output strength are illustrated with electrical output measurements as well as a study of the effect of pulse width and polarity on the active motor threshold in ten healthy volunteers. Significance. The cTMS3 features could extend the utility of TMS as a research, diagnostic, and therapeutic tool.

  20. Effects of high voltage pulse trimming on structural properties of thick-film resistors

    Directory of Open Access Journals (Sweden)

    Stanimirović Zdravko

    2017-01-01

    Full Text Available Nowadays, compact and reliable electronic devices including up-to-date ceramic micro-electro-mechanical systems require thick-film resistors with significantly reduced dimensions and stable and precise resistance values. For that reason, instead of standard laser trimming method, high voltage pulse trimming of thick-film resistors is being introduced. This method allows controlled and reliable resistance adjustment regardless of resistor position or dimensions and without the presence of cuts. However, it causes irreversible structural changes in the pseudorandom network formed during sintering causing the changes in conducting mechanisms. In this paper results of the experimental investigation of high voltage pulse trimming of thick-film resistors are presented. Obtained results are analyzed and correlations between resistance and low-frequency noise changes and changes in conducting mechanisms in resistors due to high voltage pulse trimming are observed. Sources of measured fluctuations are identified and it is shown that this type of trimming is a valid alternative trimming method to the dominant laser trimming. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. III44003 and III45007

  1. Comparison of two fat-suppressed magnetic resonance imaging pulse sequences to standard t2-weighted images for brain parenchymal contrast and lesion detection in dogs with inflammatory intracranial disease.

    Science.gov (United States)

    Young, Benjamin D; Mankin, Joseph M; Griffin, John F; Fosgate, Geoffrey T; Fowler, Jennifer L; Levine, Jonathan M

    2015-01-01

    T2-weighted (T2w) sequences are commonly relied upon in magnetic resonance imaging protocols for the detection of brain lesions in dogs. Previously, the effect of fluid suppression via fluid-attenuated inversion recovery (FLAIR) has been compared to T2-weighting with mixed results. Short tau inversion recovery (STIR) has been reported to increase the detection of some CNS lesions in people. The purpose of the current study was to evaluate the effect of fat suppression on brain parenchymal contrast resolution and lesion detection in dogs. We compared three sequences: T2w images, STIR, and T2w FLAIR with chemical fat suppression (T2-FLAIR-FS) in dogs with meningoencephalitis. Dogs with meningoencephalitis and dogs with idiopathic epilepsy were retrospectively identified and anonymized. Evaluators recorded the presence or absence of lesions within 12 predetermined brain regions on randomized sequences, viewing and scoring each sequence individually. Additionally, signal-to-noise ratios, contrast-to-noise ratios, and relative contrast (RC) were measured in a reference population. Short tau inversion recovery sequences had the highest RC between gray and white matter. While descriptively more lesions were identified by evaluators on T2-FLAIR-FS images, there was no statistical difference in the relative sensitivity of lesion detection between the sequences. Nor was there a statistical difference in false lesion detection within our reference population. Short tau inversion recovery may be favored for enhanced anatomic contrast depiction in brain imaging. No benefit of the inclusion of a fat-suppressed T2-FLAIR sequence was found. © 2014 American College of Veterinary Radiology.

  2. Zeptosecond precision pulse shaping.

    Science.gov (United States)

    Köhler, Jens; Wollenhaupt, Matthias; Bayer, Tim; Sarpe, Cristian; Baumert, Thomas

    2011-06-06

    We investigate the temporal precision in the generation of ultrashort laser pulse pairs by pulse shaping techniques. To this end, we combine a femtosecond polarization pulse shaper with a polarizer and employ two linear spectral phase masks to mimic an ultrastable common-path interferometer. In an all-optical experiment we study the interference signal resulting from two temporally delayed pulses. Our results show a 2σ-precision of 300 zs = 300 × 10(-21) s in pulse-to-pulse delay. The standard deviation of the mean is 11 zs. The obtained precision corresponds to a variation of the arm's length in conventional delay stage based interferometers of 0.45 Å. We apply these precisely generated pulse pairs to a strong-field quantum control experiment. Coherent control of ultrafast electron dynamics via photon locking by temporal phase discontinuities on a few attosecond timescale is demonstrated.

  3. Automatic sequences

    CERN Document Server

    Haeseler, Friedrich

    2003-01-01

    Automatic sequences are sequences which are produced by a finite automaton. Although they are not random they may look as being random. They are complicated, in the sense of not being not ultimately periodic, they may look rather complicated, in the sense that it may not be easy to name the rule by which the sequence is generated, however there exists a rule which generates the sequence. The concept automatic sequences has special applications in algebra, number theory, finite automata and formal languages, combinatorics on words. The text deals with different aspects of automatic sequences, in particular:· a general introduction to automatic sequences· the basic (combinatorial) properties of automatic sequences· the algebraic approach to automatic sequences· geometric objects related to automatic sequences.

  4. Pulse-train control of photofragmentation at constant field energy

    DEFF Research Database (Denmark)

    Tiwari, Ashwani Kumar; Henriksen, Niels Engholm

    2014-01-01

    We consider a phaselocked two-pulse sequence applied to photofragmentation in the weak-field limit. The two pulses are not overlapping in time, i.e., the energy of the pulse-train is constant for all time delays. It is shown that the relative yield of excited Br* in the nonadiabatic process: I + Br......*←IBr → I + Br, changes as a function of time delay when the two excited wave packets interfere. The underlying mechanisms are analyzed and the change in the branching ratio as a function of time delay is only a reflection of a changing frequency distribution of the pulse train; the branching ratio does...

  5. Pulse Tube Refrigerator

    Science.gov (United States)

    Matsubara, Yoichi

    The pulse tube refrigerator is one of the regenerative cycle refrigerators such as Stirling cycle or Gifford-McMahon cycle which gives the cooling temperature below 150 K down to liquid helium temperature. In 1963, W. E. Gifford invented a simple refrigeration cycle which is composed of compressor, regenerator and simple tube named as pulse tube which gives a similar function of the expander in Stirling or Gifford-McMahon cycle. The thermodynamically performance of this pulse tube refrigerator is inferior to that of other regenerative cycles. In 1984, however, Mikulin and coworkers made a significant advance in pulse tube configuration called as orifice pulse tube. After this, several modifications of the pulse tube hot end configuration have been developed. With those modifications, the thermodynamic performance of the pulse tube refrigerator became the same order to that of Stirling and Gifford-McMahon refrigerator. This article reviews the brief history of the pulse tube refrigerator development in the view point of its thermodynamically efficiency. Simplified theories of the energy flow in the pulse tube have also been described.

  6. Ultrashort Laser Pulse Phenomena

    CERN Document Server

    Diels, Jean-Claude

    2006-01-01

    Ultrashort Laser Pulse Phenomena, 2e serves as an introduction to the phenomena of ultra short laser pulses and describes how this technology can be used to examine problems in areas such as electromagnetism, optics, and quantum mechanics. Ultrashort Laser Pulse Phenomena combines theoretical backgrounds and experimental techniques and will serve as a manual on designing and constructing femtosecond (""faster than electronics"") systems or experiments from scratch. Beyond the simple optical system, the various sources of ultrashort pulses are presented, again with emphasis on the basic

  7. Second-order shaped pulsed for solid-state quantum computation

    Energy Technology Data Exchange (ETDEWEB)

    Sengupta, Pinaki [Los Alamos National Laboratory

    2008-01-01

    We present the construction and detailed analysis of highly optimized self-refocusing pulse shapes for several rotation angles. We characterize the constructed pulses by the coefficients appearing in the Magnus expansion up to second order. This allows a semianalytical analysis of the performance of the constructed shapes in sequences and composite pulses by computing the corresponding leading-order error operators. Higher orders can be analyzed with the numerical technique suggested by us previously. We illustrate the technique by analyzing several composite pulses designed to protect against pulse amplitude errors, and on decoupling sequences for potentially long chains of qubits with on-site and nearest-neighbor couplings.

  8. Pulse Distortion in Saturated Fiber Optical Parametric Chirped Pulse Amplification

    DEFF Research Database (Denmark)

    Lali-Dastjerdi, Zohreh; Da Ros, Francesco; Rottwitt, Karsten

    2012-01-01

    Fiber optical parametric chirped pulse amplification is experimentally compared for different chirped pulses in the picosecond regime. The amplified chirped pulses show distortion appearing as pedestals after recompression when the amplifier is operated in saturation....

  9. Chaotic Pulse Trains

    CERN Document Server

    Balmforth, N J; Spiegel, E A

    1993-01-01

    Abstract: We study a third-order nonlinear ordinary differential equation whose solutions, under certain specific conditions, are individual pulses. These correspond to homoclinic orbits in the phase space of the equation and we study the possible pulse types in some detail. Sufficiently close to the conditions under which a homoclinic orbit exists, the solutions take the form of trains of well-separated pulses. A measure of closeness to homoclinic conditions provides a small parameter for the development of an asymptotic solution consisting of superposed, isolated pulses. The solvability condition in the resulting singular perturbation theory is a {\\its timing map} relating successive pulse spacings. This map of the real line onto itself, together with the known form of the homoclinic orbit, provides a concise and accurate solution of the equation.

  10. Observation of enhanced field-free molecular alignment by two laser pulses

    DEFF Research Database (Denmark)

    Bisgaard, Christer; Poulsen, Mikael Dahlerup; Peronne, Emmanuel

    2004-01-01

    We show experimentally that field-free alignment of iodobenzene molecules, induced by a single, intense, linearly polarized 1.4-ps-long laser pulse, can be strongly enhanced by dividing the pulse into two optimally synchronized pulses of the same duration. For a given total energy of the two-puls......-pulse sequence the degree of alignment is maximized with an intensity ratio of 1:3 and by sending the second pulse near the time where the alignment created by the first pulse peaks....

  11. RF Pulsed Heating

    Energy Technology Data Exchange (ETDEWEB)

    Pritzkau, David P.

    2002-01-03

    RF pulsed heating is a process by which a metal is heated from magnetic fields on its surface due to high-power pulsed RF. When the thermal stresses induced are larger than the elastic limit, microcracks and surface roughening will occur due to cyclic fatigue. Pulsed heating limits the maximum magnetic field on the surface and through it the maximum achievable accelerating gradient in a normal conducting accelerator structure. An experiment using circularly cylindrical cavities operating in the TE{sub 011} mode at a resonant frequency of 11.424 GHz is designed to study pulsed heating on OFE copper, a material commonly used in normal conducting accelerator structures. The high-power pulsed RF is supplied by an X-band klystron capable of outputting 50 MW, 1.5 {micro}s pulses. The test pieces of the cavity are designed to be removable to allow testing of different materials with different surface preparations. A diagnostic tool is developed to measure the temperature rise in the cavity utilizing the dynamic Q change of the resonant mode due to heating. The diagnostic consists of simultaneously exciting a TE{sub 012} mode to steady-state in the cavity at 18 GHz and measuring the change in reflected power as the cavity is heated from high-power pulsed RF. Two experimental runs were completed. One run was executed at a calculated temperature rise of 120 K for 56 x 10{sup 6} pulses. The second run was executed at a calculated temperature rise of 82 K for 86 x 10{sup 6} pulses. Scanning electron microscope pictures show extensive damage occurring in the region of maximum temperature rise on the surface of the test pieces.

  12. Sequence assembly

    DEFF Research Database (Denmark)

    Scheibye-Alsing, Karsten; Hoffmann, S.; Frankel, Annett Maria

    2009-01-01

    Despite the rapidly increasing number of sequenced and re-sequenced genomes, many issues regarding the computational assembly of large-scale sequencing data have remain unresolved. Computational assembly is crucial in large genome projects as well for the evolving high-throughput technologies...... and plays an important role in processing the information generated by these methods. Here, we provide a comprehensive overview of the current publicly available sequence assembly programs. We describe the basic principles of computational assembly along with the main concerns, such as repetitive sequences...... in genomic DNA, highly expressed genes and alternative transcripts in EST sequences. We summarize existing comparisons of different assemblers and provide a detailed descriptions and directions for download of assembly programs at: http://genome.ku.dk/resources/assembly/methods.html....

  13. High performance pulse generator

    Science.gov (United States)

    Grothaus, Michael G.; Moran, Stuart L.; Hardesty, Leonard W.

    1992-06-01

    The device is a compact Marx-type generator capable of producing a high-voltage burst of pulses having risetimes less than 10 nanoseconds at repetition rates up to 10 kHz. High-pressure hydrogen switches are used as the switching elements to achieve high rep-rate. A small coaxial design provides low inductance and a fast risetime. The device may be used as a high-rep-rate high-voltage trigger generator, or as a high-voltage pulse source capable of producing up to 1 MV pulses at high repetition rates.

  14. Pulse joining cartridges

    Energy Technology Data Exchange (ETDEWEB)

    Golovashchenko, Sergey Fedorovich; Bonnen, John Joseph Francis

    2017-09-26

    A pulsed joining tool includes a tool body that defines a cavity that receives an inner tubular member and an outer tubular member and a pulse joining cartridge. The tubular members are nested together with the cartridge being disposed around the outer tubular member. The cartridge includes a conductor, such as a wire or foil, that extends around the outer tubular member and is insulated to separate a supply segment from a return segment. A source of stored electrical energy is discharged through the conductor to join the tubular members with an electromagnetic force pulse.

  15. SHORT PULSE STRETCHER

    Science.gov (United States)

    Branum, D.R.; Cummins, W.F.

    1962-12-01

    >A short pulse stretching circuit capable of stretching a short puise to enable it to be displayed on a relatively slow sweeping oscilloscope is described. Moreover, the duration of the pulse is increased by charging a capacitor through a diode and thereafter discharging the capacitor at such time as is desired. In the circuit the trigger pulse alone passes through a delay line, whereas the main signal passes through the diode only, and results in over-all circuit losses which are proportional to the low losses of the diode only. (AEC)

  16. DogPulse

    DEFF Research Database (Denmark)

    Skovgaard, Christoffer; Thomsen, Josephine Raun; Verdezoto, Nervo

    2015-01-01

    This paper presents DogPulse, an ambient awareness system to support the coordination of dog walking among family members at home. DogPulse augments a dog collar and leash set to activate an ambient shape-changing lamp and visualize the last time the dog was taken for a walk. The lamp gradually...... changes its form and pulsates its lights in order to keep the family members aware of the dog walking activity. We report the iterative prototyping of DogPulse, its implementation and its preliminary evaluation. Based on our initial findings, we present the limitations and lessons learned as well...

  17. Genome Sequencing

    DEFF Research Database (Denmark)

    Sato, Shusei; Andersen, Stig Uggerhøj

    2014-01-01

    The current Lotus japonicus reference genome sequence is based on a hybrid assembly of Sanger TAC/BAC, Sanger shotgun and Illumina shotgun sequencing data generated from the Miyakojima-MG20 accession. It covers nearly all expressed L. japonicus genes and has been annotated mainly based...... on transcriptional evidence. Analysis of repetitive sequences suggests that they are underrepresented in the reference assembly, reflecting an enrichment of gene-rich regions in the current assembly. Characterization of Lotus natural variation by resequencing of L. japonicus accessions and diploid Lotus species...... is currently ongoing, facilitated by the MG20 reference sequence...

  18. Pulsed spallation Neutron Sources

    Energy Technology Data Exchange (ETDEWEB)

    Carpenter, J.M. [Argonne National Lab., IL (United States)

    1994-12-31

    This paper reviews the early history of pulsed spallation neutron source development at Argonne and provides an overview of existing sources world wide. A number of proposals for machines more powerful than currently exist are under development, which are briefly described. The author reviews the status of the Intense Pulsed Neutron Source, its instrumentation, and its user program, and provides a few examples of applications in fundamental condensed matter physics, materials science and technology.

  19. MR-Guided Sclerotherapy of Low-Flow Vascular Malformations Using T2-Weighted Interrupted bSSFP (T2W-iSSFP): Comparison of Pulse Sequences for Visualization and Needle Guidance

    Science.gov (United States)

    Xu, Di; Herzka, Daniel A.; Gilson, Wesley D.; McVeigh, Elliot R.; Lewin, Jonathan S.; Weiss, Clifford R.

    2017-01-01

    Purpose Image-guided treatment of low-flow vascular (venous or lymphatic) malformations presents a challenging visualization problem, regardless of the imaging modality being used for guidance. The purpose of this study was to employ a new magnetic resonance imaging (MRI) sequence, T2-weighted interrupted balanced steady-state free precession (T2W-iSSFP), for real-time image guidance of needle insertion. Materials and Methods T2W-iSSFP uses variable flip angle balanced steady-state free precession (bSSFP, a.k.a. SSFP) to establish T2-weighting and fat suppression. Swine (n = 3) and patients (n = 4, three female, all with venous malformations) were enrolled in the assessment. T2-weighted turbo spin echo (T2-TSE) with spectral adiabatic inversion recovery (SPAIR), SPAIR-T2-TSE or T2-TSE for short, was used as the reference. T2-weighted half Fourier acquired single shot turbo spin echo (T2-HASTE) with SPAIR (SPAIR-T2-HASTE, T2-HASTE for short), fat saturated bSSFP (FS-SSFP), and T2W-iSSFP were imaged. Numeric metrics, namely, contrast-to-noise ratio (CNR) efficiency (CNR divided by the square root of acquisition time) and local sharpness (the reciprocal of edge width), were used to assess image quality. MR-guided sclerotherapy was performed on the same patients using real-time T2W-iSSFP to guide needle insertion. Results Comparing the visualization of needles in the images of swine, the local sharpness (mm−1) was: 0.21 ± 0.06 (T2-HASTE), 0.48 ± 0.02 (FS-SSFP), and 0.49 ± 0.03 (T2W-iSSFP). T2W-iSSFP is higher than T2-HASTE (P images, their CNR efficiencies were: 797 ± 66 (T2-HASTE), 281 ± 44 (FS-SSFP), and 860 ± 29 (T2W-iSSFP). T2W-iSSFP is higher than FS-SSFP (P images are needed. PMID:24395498

  20. Composite pulses for RF phase encoded MRI: A simulation study.

    Science.gov (United States)

    Salajeghe, Somaie; Babyn, Paul; Sarty, Gordon E

    2017-02-01

    In B1 encoded MRI, a realistic non-linear phase RF encoding coil will generate an inhomogeneous B1 field that leads to spatially dependent flip angles. The non-linearity of the B1 phase gradient can be compensated for in the reconstruction, but B1 inhomogeneity remains a problem. The effect of B1 inhomogeneity on tip angles for conventional, B0 encoded MRI, may be minimized using composite pulses. The objective of this study was to explore the feasibility of using composite pulses with non-linear RF phase encoding coils and to identify the most appropriate composite pulse scheme. RF encoded signals were simulated via the Bloch equation for various symmetric, asymmetric and antisymmetric composite pulses. The simulated signals were reconstructed using a constrained least squares method. Root mean square reconstruction errors varied from 6% (for an asymmetric composite pulse) to 9.7% (for an antisymmetric composite pulse). An asymmetric composite pulse scheme created images with fewer artifacts than other composite pulse schemes in inhomogeneous B0 and B1 fields making it the best choice for decreasing the effects of spatially varying flip angles. This is contrary to the conclusion that antisymmetric composite pulses are the best ones to use for spin echo sequences in conventional, B0 encoded, MRI. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  1. Obtaining two attosecond pulses pulses for x-ray stimulated Raman spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Zholents, Alexander; Penn, G.

    2009-06-23

    Attosecond x-ray pulses are an indispensable tool for the study of electronic and structural changes in molecules undergoing chemical reactions. They have a wide bandwidth comparable to the energy bands of valence electronic states and, therefore, are well suited for making and probing multiple valence electronic excitations using core electron transitions. Here we propose a method of creating a sequence of two attosecond soft x-ray pulses in a free electron laser by optical manipulation of electrons located in two different sections of the electron bunch. The energy of each x-ray pulse can be of the order of 100 nJ and the pulse width of the order of 250 attoseconds. The carrier frequency of each x-ray pulse can be independently tuned to a resonant core electron transition of a specific atom of the molecule. The time interval between the two attosecond pulses is tunable from a few femtoseconds to a hundred femtoseconds with better than 100 attoseconds precision.

  2. Pseudo-random-bit-sequence phase modulation for reduced errors in a fiber optic gyroscope.

    Science.gov (United States)

    Chamoun, Jacob; Digonnet, Michel J F

    2016-12-15

    Low noise and drift in a laser-driven fiber optic gyroscope (FOG) are demonstrated by interrogating the sensor with a low-coherence laser. The laser coherence was reduced by broadening its optical spectrum using an external electro-optic phase modulator driven by either a sinusoidal or a pseudo-random bit sequence (PRBS) waveform. The noise reduction measured in a FOG driven by a modulated laser agrees with the calculations based on the broadened laser spectrum. Using PRBS modulation, the linewidth of a laser was broadened from 10 MHz to more than 10 GHz, leading to a measured FOG noise of only 0.00073  deg/√h and a drift of 0.023  deg/h. To the best of our knowledge, these are the lowest noise and drift reported in a laser-driven FOG, and this noise is below the requirement for the inertial navigation of aircraft.

  3. Pulse shaping with transmission lines

    Science.gov (United States)

    Wilcox, Russell B.

    1987-01-01

    A method and apparatus for forming shaped voltage pulses uses passive reflection from a transmission line with nonuniform impedance. The impedance of the reflecting line varies with length in accordance with the desired pulse shape. A high voltage input pulse is transmitted to the reflecting line. A reflected pulse is produced having the desired shape and is transmitted by pulse removal means to a load. Light activated photoconductive switches made of silicon can be utilized. The pulse shaper can be used to drive a Pockels cell to produce shaped optical pulses.

  4. Molecular spinning by a chiral train of short laser pulses

    Science.gov (United States)

    Floß, Johannes; Averbukh, Ilya Sh.

    2012-12-01

    We provide a detailed theoretical analysis of molecular rotational excitation by a chiral pulse train, a sequence of linearly polarized pulses with the polarization direction rotating from pulse to pulse by a controllable angle. Molecular rotation with a preferential rotational sense (clockwise or counterclockwise) can be excited by this scheme. We show that the directionality of the rotation is caused by quantum interference of different excitation pathways. The chiral pulse train is capable of selective excitation of molecular isotopologs and nuclear spin isomers in a mixture. We demonstrate this using 14N2 and 15N2 as examples for isotopologs and para- and ortho-nitrogen as examples for nuclear-spin isomers.

  5. [Pulse oximetry in pediatric practice].

    Science.gov (United States)

    Brackel, H J; van Essen-Zandvliet, E E; de Jongste, J C; Kerrebijn, K F

    1990-02-01

    Pulse oximetry is a reliable technique for continuous, transcutaneous measurement of oxygen saturation and pulse frequency. Common indications for pulse oximetry in general pediatrics include: monitoring of oxygenation during an asthma attack, detection of apnea or hypoventilation, diagnosis of hypoxemia in patients with chronic respiratory insufficiency and monitoring of oxygen suppletion. In this article we discuss the various applications and limitations of pulse oximetry in clinical practice and describe a method to store, analyse and present pulse oximeter-results.

  6. Pulsed welding plasma source

    Science.gov (United States)

    Knyaz'kov, A.; Pustovykh, O.; Verevkin, A.; Terekhin, V.; Shachek, A.; Tyasto, A.

    2016-04-01

    It is shown that in order to form the current pulse of a near rectangular shape, which provides conversion of the welding arc into a dynamic mode, it is rational to connect a forming element made on the basis of an artificial forming line in series to the welding DC circuit. The paper presents a diagram of a pulsed device for welding with a non-consumable electrode in argon which was developed using the forming element. The conversion of the arc into the dynamic mode is illustrated by the current and voltage oscillograms of the arc gap and the dynamic characteristic of the arc within the interval of one pulse generation time in the arc gap. The background current travels in the interpulse interval.

  7. Discharge pulse phenomenology

    Science.gov (United States)

    Frederickson, A. R.

    1985-01-01

    A model was developed which places radiation induced discharge pulse results into a unified conceptual framework. Only two phenomena are required to interpret all space and laboratory results: (1) radiation produces large electrostatic fields inside insulators via the trapping of a net space charge density; and (2) the electrostatic fields initiate discharge streamer plasmas similar to those investigated in high voltage electrical insulation materials; these streamer plasmas generate the pulsing phenomena. The apparent variability and diversity of results seen is an inherent feature of the plasma streamer mechanism acting in the electric fields which is created by irradiation of the dielectrics. The implications of the model are extensive and lead to constraints over what can be done about spacecraft pulsing.

  8. Millimicrosecond pulse techniques

    CERN Document Server

    Lewis, Ian A D

    1959-01-01

    Millimicrosecond Pulse Techniques, Second Edition focuses on millimicrosecond pulse techniques and the development of devices of large bandwidth, extending down to comparatively low frequencies (1 Mc/s). Emphasis is on basic circuit elements and pieces of equipment of universal application. Specific applications, mostly in the field of nuclear physics instrumentation, are considered. This book consists of eight chapters and opens with an introduction to some of the terminology employed by circuit engineers as well as theoretical concepts, including the laws of circuit analysis, Fourier analysi

  9. Pulsed ESP handles AFBC

    Energy Technology Data Exchange (ETDEWEB)

    Larva, J.; Wilkomm, T.; Lugar, T.; Follett, R.E.

    1988-08-01

    The Black Dog 2 retrofit AFBC at Burnsville, Minnesota started coal firing in June 1986 using the units' existing precipitators for particulate control. The effects of various fuel blends, bed material, pulse power supplies and air atomized water injection flue gas conditioning were studied. The plant has been used for tests in the following areas: fired clay bed material, higher sulfur coal blends, ash recycle optimization, improved boiler operation, improved air heater thermal performance, improved rapper effectiveness, barbed wire electrodes, intermittent energization controls, pulse energization, and water injection. 4 refs., 4 figs., 1 tab.

  10. Pulse Doppler radar

    CERN Document Server

    Alabaster, Clive

    2012-01-01

    This book is a practitioner's guide to all aspects of pulse Doppler radar. It concentrates on airborne military radar systems since they are the most used, most complex, and most interesting of the pulse Doppler radars; however, ground-based and non-military systems are also included. It covers the fundamental science, signal processing, hardware issues, systems design and case studies of typical systems. It will be a useful resource for engineers of all types (hardware, software and systems), academics, post-graduate students, scientists in radar and radar electronic warfare sectors and milit

  11. Effects of regularity on the processing of sound omission in a tone sequence in musicians and non-musicians.

    Science.gov (United States)

    Ono, Kentaro; Matsuhashi, Masao; Mima, Tatsuya; Fukuyama, Hidenao; Altmann, Christian F

    2013-09-01

    Numerous studies have reported that perceptual grouping affects the pre-attentive processing of sound omission in a sequence of tones. However, it remains unclear whether or not the perceptual grouping and musical experience affect the attentive processing of sound omission. To this end, we created a sequence of loud (L) and soft (S) tones grouped as 'LLSLLS…' and a random sequence of the L and S tones. The omission of the L tones was inserted pseudo-randomly in the random sequence, and there were two positions at which it was inserted. For within-group omission, the omission was after the first L tone within the 'LLS' pattern. For between-group omission, the omission was inserted between the patterns. The brain response to the omission in musicians and non-musicians was measured using magnetoencephalography. During the magnetoencephalography measurement, the subjects' performance in a task to detect the omission was faster in the random sequence than in the group sequence. Source analysis showed that the omission in the random sequence caused greater activity than that in the group sequence. The increase was found in the right inferior parietal lobe in musicians, whereas it was found in the left superior temporal gyrus in non-musicians. These results suggest that the attentive processing of perceptual grouping might implicate the left superior temporal gyrus or right inferior parietal lobe, depending on musical experience. © 2013 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  12. Optogenetic light pulses generator

    Science.gov (United States)

    Erofeev, A. I.; Matveev, M. V.; Zakharova, O. A.; Terekhin, S. G.; Kilimnik, V. A.; Bezprozvanny, I. B.; Vlasova, O. L.

    2017-11-01

    To date, optogenetics is one of the most popular methods in the world in neuroscience. There are new equipment and devices created to keep the progress of this method. This article describes a light pulse generator developed at the Laboratory of Molecular Neurodegeneration, designed for optogenetic experiments.

  13. Pulsed electric fields

    Science.gov (United States)

    The concept of pulsed electric fields (PEF) was first proposed in 1967 to change the behavior or microorganisms. The electric field phenomenon was identified as membrane rupture theory in the 1980s. Increasing the membrane permeability led to the application of PEF assisted extraction of cellular co...

  14. Quantitative sodium imaging with a flexible twisted projection pulse sequence

    National Research Council Canada - National Science Library

    Lu, Aiming; Atkinson, Ian C; Claiborne, Theodore C; Damen, Frederick C; Thulborn, Keith R

    2010-01-01

    The quantification of sodium MR images from an arbitrary intensity scale into a bioscale fosters image interpretation in terms of the spatially resolved biochemical process of sodium ion homeostasis...

  15. A compact nanosecond pulse modulator

    Science.gov (United States)

    Sha, Jizhang; Xue, Jianchao; Qiang, Bohan

    Two circuits of nanosecond pulse modulator which generate two different width rectangular pulses respectively are described. The basic configuration of the modulator is the Marx circuit, in which avalanche transistors are used as switching devices. In order to obtain the rectangular pulses a pulse-forming network (PFN) is introduced and fitted into the Marx. A multi-parallel arrangement of the Marx is used to satisfy the broad pulse requirement. Experiments have shown that the two different width rectangular pulses which have 130 V amplitudes and 30 and 200 ns widths respectively can be obtained at a 50 ohms load. The two pulses have steep front edges (3.6 ns and 10 ns respectively) and flat tops with less than + or - 5 percent ripples. Therefore, the modulator can meet the requirements of the nanosecond pulse radar.

  16. Wide spectrum microwave pulse measurement

    Energy Technology Data Exchange (ETDEWEB)

    King, R.J.

    1986-01-01

    Various techniques are postulated as diagnostics for wide band microwave pulses. The diagnostics include determinations of both the instantaneous amplitude and the frequency content of one-shot pulses. 6 refs., 11 figs. (WRF)

  17. Main: Sequences [KOME

    Lifescience Database Archive (English)

    Full Text Available Sequences Nucleotide Sequence Nucleotide sequence of full length cDNA (trimmed sequence) kome_ine_full_se...quence_db.fasta.zip kome_ine_full_sequence_db.zip kome_ine_full_sequence_db ...

  18. Sequentially pulsed traveling wave accelerator

    Science.gov (United States)

    Caporaso, George J [Livermore, CA; Nelson, Scott D [Patterson, CA; Poole, Brian R [Tracy, CA

    2009-08-18

    A sequentially pulsed traveling wave compact accelerator having two or more pulse forming lines each with a switch for producing a short acceleration pulse along a short length of a beam tube, and a trigger mechanism for sequentially triggering the switches so that a traveling axial electric field is produced along the beam tube in synchronism with an axially traversing pulsed beam of charged particles to serially impart energy to the particle beam.

  19. Bacterial inactivation using pulsed light

    OpenAIRE

    Elmnasser, Noura; Ritz, Magali; Leroi, Francoise; Orange, Nicole; Bakhrouf, Amina; Federighi, Michel

    2007-01-01

    Pulsed light is a new method intended for the decontamination of food surfaces using short, high frequency pulses of an intense broad spectrum. The effects of broad spectrum pulsed light on the survival of Listeria monocytogenes Scott A, Listeria monocytogenes CNL, Pseudomonas fluorescens MF37 and Photobacterium phosphoreum SF680 populations on agar and in a liquid medium were investigated during this study. The sterilisation system generated 1.5 J cm(-2) per pulse with eight lamps for 300 mu...

  20. International magnetic pulse compression

    Science.gov (United States)

    Kirbie, H. C.; Newton, M. A.; Siemens, P. D.

    1991-04-01

    Although pulsed-power engineering traditionally has been practiced by a fairly small, close community in the areas of defense and energy research, it is becoming more common in high-power, high-energy commercial pursuits such as material processing and lasers. This paper is a synopsis of the Feb. 12-14, 1990 workshop on magnetic switching as it applies primarily to pulse compression (power transformation). During the course of the Workshop at Granlibakken, a great deal of information was amassed and a keen insight into both the problems and opportunities as to the use of this switching approach was developed. The segmented workshop format proved ideal for identifying key aspects affecting optimum performance in a variety of applications. Individual groups of experts addressed network and system modeling, magnetic materials, power conditioning, core cooling and dielectrics, and finally circuits and application. At the end, they came together to consolidate their input and formulate the workshop's conclusions, identifying roadblocks or suggesting research projects, particularly as they apply to magnetic switching's trump card - its high-average-power-handling capability (at least on a burst-mode basis). The workshop was especially productive both in the quality and quantity of information transfer in an environment conducive to a free and open exchange of ideas. We will not delve into the organization proper of this meeting, rather we wish to commend to the interested reader this volume, which provides the definitive and most up-to-date compilation on the subject of magnetic pulse compression from underlying principles to current state of the art as well as the prognosis for the future of magnetic pulse compression as a consensus of the workshop's organizers and participants.

  1. PULSE Pilot Certification Results

    Directory of Open Access Journals (Sweden)

    Pamela Pape-Lindstrom

    2015-08-01

    Full Text Available The pilot certification process is an ambitious, nationwide endeavor designed to motivate important changes in life sciences education that are in line with the recommendations of the 2011 Vision and Change Report: A Call to Action (American Association for the Advancement of Science [AAAS], 2011.  It is the goal of the certification process to acknowledge departments that have progressed towards full implementation of the tenets of Vision and Change and to motivate departments that have not begun to adopt the recommendations to consider doing so.  More than 70 life science departments applied to be part of the pilot certification process, funded by a National Science Foundation grant, and eight were selected based on initial evidence of transformed and innovative educational practices.  The programs chosen represent a wide variety of schools, including two-year colleges, liberal-arts institutions, regional comprehensive colleges, research universities and minority serving institutions.  Outcomes from this pilot were released June 1, 2015 (www.pulsecommunity.org, with all eight programs being recognized as having progressed along a continuum of change.  Five levels of achievement were defined as PULSE Pilot Progression Levels.  Of the eight departments in the pilot, one achieved “PULSE Progression Level III: Accomplished”.  Six departments achieved “PULSE Progression Level II: Developing” and one pilot department achieved “PULSE Progression Level I: Beginning”.  All of the schools have made significant movement towards the recommendations of Vision and Change relative to a traditional life sciences curriculum.  Overall, the response from the eight pilot schools has been positive. 

  2. STUCTURE OF PULSED BED

    Directory of Open Access Journals (Sweden)

    I. A. Bokun

    2014-01-01

    Full Text Available The structure of pulsed layer is proposed which can be suggested as a state of particulates that is blown by intermittent gas flow with speed which has the force to start material moving. Layer during one cycle is in a suspension, falling down and immobile state resulting in changes of particles arrangement as well as ways of gas flowing through layer. Moreover, it allows carrying out effective interphase heat exchange even adamant real granulation.The process of formation of impact flows is considered aw well as their influence on formation of air bubbles in pulsed layer. At startup of air blast the balance between the force of hydro-dynamic resistance is broken, on one side, and forces of gravity, particles inertia and their links with walls on the other side. The layer is transferred in the state of pulsed pseudo-fluidization, and presents gas-disperse mixture, inside of which impulse of pressure increasing is spreading to all sides as pressure waves (compression. These waves are the sources of impact flows’ formation, the force of which is two times more than during the stationary flow.The waves of pressure are divided into weak and strong ones depending on movement velocity within gas-disperse system. Weak waves are moving with a sound speed and strong ones in active phase of pulsed layer are moving over the speed of sound limit within gas-disperse system. The peculiarity of strong wave is that parameters of system (pressure, density and others are changing in discrete steps.The article describes the regime of layer’s falling down in the passive stage of cycle, which begins after finishing of gas impulse action. And suspension layer of moving up granular material is transferred in the state of falling resulting in change of the layer structure.

  3. Modeling Pilot Pulse Control

    Science.gov (United States)

    Bachelder, Edward; Hess, Ronald; Godfroy-Cooper, Martine; Aponso, Bimal

    2017-01-01

    In this study, behavioral models are developed that closely reproduced pulsive control response of two pilots from the experimental pool using markedly different control techniques (styles) while conducting a tracking task. An intriguing find was that the pilots appeared to: 1) produce a continuous, internally-generated stick signal that they integrated in time; 2) integrate the actual stick position; and 3) compare the two integrations to issue and cease pulse commands. This suggests that the pilots utilized kinesthetic feedback in order to perceive and integrate stick position, supporting the hypothesis that pilots can access and employ the proprioceptive inner feedback loop proposed by Hess' pilot Structural Model. The Pulse Models used in conjunction with the pilot Structural Model closely recreated the pilot data both in the frequency and time domains during closed-loop simulation. This indicates that for the range of tasks and control styles encountered, the models captured the fundamental mechanisms governing pulsive and control processes. The pilot Pulse Models give important insight for the amount of remnant (stick output uncorrelated with the forcing function) that arises from nonlinear pilot technique, and for the remaining remnant arising from different sources unrelated to tracking control (i.e. neuromuscular tremor, reallocation of cognitive resources, etc.).

  4. Controlling the dipole-dipole interaction using NMR composite rf pulses

    Science.gov (United States)

    Baudin, Emmanuel

    2014-08-01

    New composite rf pulses are proposed during which the average dipole-dipole interactions within a spin ensemble are controlled, while a global rotation is achieved. The method used to tailor the pulses is based on the average Hamiltonian theory and relies on the geometrical properties of the spin-spin dipolar interaction. I describe several such composite pulses and analyze quantitatively the improvement brought on the control of the NMR dynamics. Numerical simulations show that the magic sandwich pulse sequence, during which the average dipolar field is effectively reversed, is plagued by defects originating from the finite initial and final π/2 rf pulses. A numerical test based on a classical description of nuclear magnetic resonance is used to check that, when these pulses are replaced by magic composite pulses, the efficiency of the magic sandwich is improved.

  5. Dynamics of a pulsed continuous-variable quantum memory

    DEFF Research Database (Denmark)

    Dantan, Aurelien Romain; Cviklinski, Jean; Pinard, Michel

    2006-01-01

    We study the transfer dynamics of nonclassical fluctuations of light to the ground-state collective spin components of an atomic ensemble during a pulsed quantum memory sequence, and evaluate the relevant physical quantities to be measured in order to characterize such a quantum memory. We show...... transmission—that accounts for the behavior of the atomic quantum memory....

  6. Petawatt pulsed-power accelerator

    Science.gov (United States)

    Stygar, William A.; Cuneo, Michael E.; Headley, Daniel I.; Ives, Harry C.; Ives, legal representative; Berry Cottrell; Leeper, Ramon J.; Mazarakis, Michael G.; Olson, Craig L.; Porter, John L.; Wagoner; Tim C.

    2010-03-16

    A petawatt pulsed-power accelerator can be driven by various types of electrical-pulse generators, including conventional Marx generators and linear-transformer drivers. The pulsed-power accelerator can be configured to drive an electrical load from one- or two-sides. Various types of loads can be driven; for example, the accelerator can be used to drive a high-current z-pinch load. When driven by slow-pulse generators (e.g., conventional Marx generators), the accelerator comprises an oil section comprising at least one pulse-generator level having a plurality of pulse generators; a water section comprising a pulse-forming circuit for each pulse generator and a level of monolithic triplate radial-transmission-line impedance transformers, that have variable impedance profiles, for each pulse-generator level; and a vacuum section comprising triplate magnetically insulated transmission lines that feed an electrical load. When driven by LTD generators or other fast-pulse generators, the need for the pulse-forming circuits in the water section can be eliminated.

  7. Noseleaf dynamics during pulse emission in horseshoe bats.

    Directory of Open Access Journals (Sweden)

    Lin Feng

    Full Text Available Horseshoe bats emit their biosonar pulses nasally and diffract the outgoing ultrasonic waves by conspicuous structures that surrounded the nostrils. Here, we report quantitative experimental data on the motion of a prominent component of these structures, the anterior leaf, using synchronized laser Doppler vibrometry and acoustic recordings in the greater horseshoe bat (Rhinolophus ferrumequinum. The vibrometry data has demonstrated non-random motion patterns in the anterior leaf. In these patterns, the outer rim of the walls of the anterior leaf twitches forward and inwards to decrease the aperture of the noseleaf and increase the curvature of its surfaces. Noseleaf displacements were correlated with the emitted ultrasonic pulses. After their onset, the inward displacements increased monotonically towards their maximum value which was always reached within the duration of the biosonar pulse, typically towards its end. In other words, the anterior leaf's surfaces were moving inwards during most of the pulse. Non-random motions were not present in all recorded pulse trains, but could apparently be switched on or off. Such switches happened between sequences of consecutive pulses but were never observed between individual pulses within a sequence. The amplitudes of the emitted biosonar pulse and accompanying noseleaf movement were not correlated in the analyzed data set. The measured velocities of the noseleaf surface were too small to induce Doppler shifts of a magnitude with a likely significance. However, the displacement amplitudes were significant in comparison with the overall size of the anterior leaf and the sound wavelengths. These results indicate the possibility that horseshoe bats use dynamic sensing principles on the emission side of their biosonar system. Given the already available evidence that such mechanisms exist for biosonar reception, it may be hypothesized that time-variant mechanisms play a pervasive role in the biosonar

  8. Noseleaf dynamics during pulse emission in horseshoe bats.

    Science.gov (United States)

    Feng, Lin; Gao, Li; Lu, Hongwang; Müller, Rolf

    2012-01-01

    Horseshoe bats emit their biosonar pulses nasally and diffract the outgoing ultrasonic waves by conspicuous structures that surrounded the nostrils. Here, we report quantitative experimental data on the motion of a prominent component of these structures, the anterior leaf, using synchronized laser Doppler vibrometry and acoustic recordings in the greater horseshoe bat (Rhinolophus ferrumequinum). The vibrometry data has demonstrated non-random motion patterns in the anterior leaf. In these patterns, the outer rim of the walls of the anterior leaf twitches forward and inwards to decrease the aperture of the noseleaf and increase the curvature of its surfaces. Noseleaf displacements were correlated with the emitted ultrasonic pulses. After their onset, the inward displacements increased monotonically towards their maximum value which was always reached within the duration of the biosonar pulse, typically towards its end. In other words, the anterior leaf's surfaces were moving inwards during most of the pulse. Non-random motions were not present in all recorded pulse trains, but could apparently be switched on or off. Such switches happened between sequences of consecutive pulses but were never observed between individual pulses within a sequence. The amplitudes of the emitted biosonar pulse and accompanying noseleaf movement were not correlated in the analyzed data set. The measured velocities of the noseleaf surface were too small to induce Doppler shifts of a magnitude with a likely significance. However, the displacement amplitudes were significant in comparison with the overall size of the anterior leaf and the sound wavelengths. These results indicate the possibility that horseshoe bats use dynamic sensing principles on the emission side of their biosonar system. Given the already available evidence that such mechanisms exist for biosonar reception, it may be hypothesized that time-variant mechanisms play a pervasive role in the biosonar sensing of horseshoe

  9. Foundations of pulsed power technology

    CERN Document Server

    Lehr, Janet

    2018-01-01

    Pulsed power technologies could be an answer to many cutting-edge applications. The challenge is in how to develop this high-power/high-energy technology to fit current market demands of low-energy consuming applications. This book provides a comprehensive look at pulsed power technology and shows how it can be improved upon for the world of today and tomorrow. Foundations of Pulsed Power Technology focuses on the design and construction of the building blocks as well as their optimum assembly for synergetic high performance of the overall pulsed power system. Filled with numerous design examples throughout, the book offers chapter coverage on various subjects such as: Marx generators and Marx-like circuits; pulse transformers; pulse-forming lines; closing switches; opening switches; multi-gigawatt to multi-terawatt systems; energy storage in capacitor banks; electrical breakdown in gases; electrical breakdown in solids, liquids and vacuum; pulsed voltage and current measurements; electromagnetic interferen...

  10. Data transmission system with encryption by chaotic sequences

    Directory of Open Access Journals (Sweden)

    Politans’kyy R. L.

    2014-06-01

    Full Text Available Protection of transferable information in the telecommunication systems is possible by its imposition of coding sequence on a plaintext. Encryption of pseudorandom sequences can be performed by using generation algorithms which are implemented on the basis of the phenomenon of dynamical chaos, which is sensitive to changes in the initial conditions. One of the major problems encountered in the construction of secure communication systems is to provide synchronization between the receiving and transmitting parties of communication systems. Improvement of methods of hidden data transfer based on the systems with chaotic synchronization is the important task of research in the field of information and telecommunication systems based on chaos. This article shows an implementation of a data transmission system, encrypted by sequences, generated on the basis of one-dimensional discrete chaotic maps with ensuring synchronization of the transmitting and receiving sides of the system. In this system realization of synchronization is offered by a transmission through certain time domains of current value of xn generated by a logistic reflection. Xn transmission period depends on computer speed and distance between subscribers of the system. Its value is determined by transmitting a test message before the session. Infallible reception of test message indicates the optimal choice of a transmission period of the current value of xn. Selection period is done at the program level. For the construction of communication network modern software was used, in particular programming language Delphi 7.0. The work of the system is shown on the example of information transmission between the users of the system. The system operates in real time full duplex mode at any hardware implementation of Internet access. It is enough for the users of the system to specify IP address only.

  11. Coiled transmission line pulse generators

    Science.gov (United States)

    McDonald, Kenneth Fox

    2010-11-09

    Methods and apparatus are provided for fabricating and constructing solid dielectric "Coiled Transmission Line" pulse generators in radial or axial coiled geometries. The pour and cure fabrication process enables a wide variety of geometries and form factors. The volume between the conductors is filled with liquid blends of monomers, polymers, oligomers, and/or cross-linkers and dielectric powders; and then cured to form high field strength and high dielectric constant solid dielectric transmission lines that intrinsically produce ideal rectangular high voltage pulses when charged and switched into matched impedance loads. Voltage levels may be increased by Marx and/or Blumlein principles incorporating spark gap or, preferentially, solid state switches (such as optically triggered thyristors) which produce reliable, high repetition rate operation. Moreover, these Marxed pulse generators can be DC charged and do not require additional pulse forming circuitry, pulse forming lines, transformers, or an a high voltage spark gap output switch. The apparatus accommodates a wide range of voltages, impedances, pulse durations, pulse repetition rates, and duty cycles. The resulting mobile or flight platform friendly cylindrical geometric configuration is much more compact, light-weight, and robust than conventional linear geometries, or pulse generators constructed from conventional components. Installing additional circuitry may accommodate optional pulse shape improvements. The Coiled Transmission Lines can also be connected in parallel to decrease the impedance, or in series to increase the pulse length.

  12. Microwave and Pulsed Power

    Energy Technology Data Exchange (ETDEWEB)

    Freytag, E.K.

    1993-03-01

    The goals of the Microwave and Pulsed Power thrust area are to identify realizable research and development efforts and to conduct high-quality research in those pulse power and microwave technologies that support existing and emerging programmatic requirements at Lawrence Livermore National Laboratory (LLNL). Our main objective is to work on nationally important problems while enhancing our basic understanding of enabling technologies such as component design and testing, compact systems packaging, exploratory physics experiments, and advanced systems integration and performance. During FY-92, we concentrated our research efforts on the six project areas described in this report. (1) We are investigating the superior electronic and thermal properties of diamond that may make it an ideal material for a high-power, solid-state switch. (2) We are studying the feasibility of using advanced Ground Penetrating Imaging Radar technology for reliable non-destructive evaluation of bridges and other high-value concrete structures. These studies include conceptual designs, modeling, experimental verifications, and image reconstruction of simulated radar data. (3) We are exploring the efficiency of pulsed plasma processing techniques used for the removal of NO{sub x} from various effluent sources. (4) We have finished the investigation of the properties of a magnetically delayed low-pressure gas switch, which was designed here at LLNL. (5) We are applying statistical electromagnetic theory techniques to help assess microwave effects on electronic subsystems, by using a mode stirred chamber as our measurement tool. (6) We are investigating the generation of perfluoroisobutylene (PFIB) in proposed CFC replacement fluids when they are subjected to high electrical stresses and breakdown environments.

  13. Intense pulsed light therapy.

    Science.gov (United States)

    Soltes, Barbara

    2010-12-01

    Intense Pulsed Light (IPL) is an FDA-approved photo therapy for the treatment of a variety of conditions such as acne and hirsutism. It utilizes the principle of selective photothermolysis. Photothermolysis allows a specific wavelength to be delivered to a chromophore of a designated tissue while leaving the surrounding tissue unaffected. The results of IPL are similar to that of laser treatments but it offers the advantage of a relative low cost. It is a safe and rapid treatment with minimal discomfort to the patient. Copyright © 2010 Elsevier Inc. All rights reserved.

  14. A Pulsed Sphere Tutorial

    Energy Technology Data Exchange (ETDEWEB)

    Cullen, Dermott E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-01-30

    Here I attempt to explain what physically happens when we pulse an object with neutrons, specifically what we expect the time dependent behavior of the neutron population to look like. Emphasis is on the time dependent emission of both prompt and delayed neutrons. I also describe how the TART Monte Carlo transport code models this situation; see the appendix for a complete description of the model used by TART. I will also show that, as we expect, MCNP and MERCURY, produce similar results using the same delayed neutron model (again, see the appendix).

  15. Africa's Pulse, October 2014

    OpenAIRE

    Punam, Chuhan-Pole; Ferreira, Francisco H. G.

    2014-01-01

    Africa’s Pulse is a biannual publication containing an analysis of the near-term macro-economic outlook for the region. It also includes a section focusing on a topic that represents a particular development challenges for the continent. It is produced by the Office of the Chief Economist for the Africa Region.This issue is an analysis of issues shaping Africa's economic future. Growth remains stable in Sub-Saharan Africa. Some countries are seeing a slowdown, but the region's economic pros...

  16. Increasing flexibility in two-dimensional liquid chromatography by pulsed elution of the first dimension

    DEFF Research Database (Denmark)

    Jakobsen, Simon S.; Christensen, Jan H.; Verdier, Sylvain

    2017-01-01

    This work demonstrates the development of an online two-dimensional liquid chromatography (2D-LC) method where the first dimension column is eluted by a sequence of pulses of increasing eluotropic strength generated by the LC pumps (pulsed-elution 2D-LC). Between the pulses, the first dimension...... online comprehensive 2D-LC: undersampling, difficulties in refocusing, and lack of flexibility in the selection of column dimensions and flow rates because the two dimensions constrain each other. The pulsed-elution 2D-LC was applied for the analysis of a basic fraction of vacuum gas oil. Peak capacity...

  17. Radiofrequency pulse design in parallel transmission under strict temperature constraints.

    Science.gov (United States)

    Boulant, Nicolas; Massire, Aurélien; Amadon, Alexis; Vignaud, Alexandre

    2014-09-01

    To gain radiofrequency (RF) pulse performance by directly addressing the temperature constraints, as opposed to the specific absorption rate (SAR) constraints, in parallel transmission at ultra-high field. The magnitude least-squares RF pulse design problem under hard SAR constraints was solved repeatedly by using the virtual observation points and an active-set algorithm. The SAR constraints were updated at each iteration based on the result of a thermal simulation. The numerical study was performed for an SAR-demanding and simplified time of flight sequence using B1 and ΔB0 maps obtained in vivo on a human brain at 7T. The proposed adjustment of the SAR constraints combined with an active-set algorithm provided higher flexibility in RF pulse design within a reasonable time. The modifications of those constraints acted directly upon the thermal response as desired. Although further confidence in the thermal models is needed, this study shows that RF pulse design under strict temperature constraints is within reach, allowing better RF pulse performance and faster acquisitions at ultra-high fields at the cost of higher sequence complexity. Copyright © 2013 Wiley Periodicals, Inc.

  18. Bipolar pulse forming line

    Science.gov (United States)

    Rhodes, Mark A.

    2008-10-21

    A bipolar pulse forming transmission line module for linear induction accelerators having first, second, third, fourth, and fifth planar conductors which form an interleaved stack with dielectric layers between the conductors. Each conductor has a first end, and a second end adjacent an acceleration axis. The first and second planar conductors are connected to each other at the second ends, the fourth and fifth planar conductors are connected to each other at the second ends, and the first and fifth planar conductors are connected to each other at the first ends via a shorting plate adjacent the first ends. The third planar conductor is electrically connectable to a high voltage source, and an internal switch functions to short a high voltage from the first end of the third planar conductor to the first end of the fourth planar conductor to produce a bipolar pulse at the acceleration axis with a zero net time integral. Improved access to the switch is enabled by an aperture through the shorting plate and the proximity of the aperture to the switch.

  19. Heat driven pulse pump

    Science.gov (United States)

    Benner, Steve M (Inventor); Martins, Mario S. (Inventor)

    2000-01-01

    A heat driven pulse pump includes a chamber having an inlet port, an outlet port, two check valves, a wick, and a heater. The chamber may include a plurality of grooves inside wall of the chamber. When heated within the chamber, a liquid to be pumped vaporizes and creates pressure head that expels the liquid through the outlet port. As liquid separating means, the wick, disposed within the chamber, is to allow, when saturated with the liquid, the passage of only liquid being forced by the pressure head in the chamber, preventing the vapor from exiting from the chamber through the outlet port. A plurality of grooves along the inside surface wall of the chamber can sustain the liquid, which is amount enough to produce vapor for the pressure head in the chamber. With only two simple moving parts, two check valves, the heat driven pulse pump can effectively function over the long lifetimes without maintenance or replacement. For continuous flow of the liquid to be pumped a plurality of pumps may be connected in parallel.

  20. Assembly delay line pulse generators

    CERN Multimedia

    CERN PhotoLab

    1971-01-01

    Assembly of six of the ten delay line pulse generators that will power the ten kicker magnet modules. One modulator part contains two pulse generators. Capacitors, inductances, and voltage dividers are in the oil tank on the left. Triggered high-pressure spark gap switches are on the platforms on the right. High voltage pulse cables to the kicker magnet emerge under the spark gaps. In the centre background are the assembled master gaps.

  1. Pulsed power accelerator for material physics experiments

    Directory of Open Access Journals (Sweden)

    D. B. Reisman

    2015-09-01

    Full Text Available We have developed the design of Thor: a pulsed power accelerator that delivers a precisely shaped current pulse with a peak value as high as 7 MA to a strip-line load. The peak magnetic pressure achieved within a 1-cm-wide load is as high as 100 GPa. Thor is powered by as many as 288 decoupled and transit-time isolated bricks. Each brick consists of a single switch and two capacitors connected electrically in series. The bricks can be individually triggered to achieve a high degree of current pulse tailoring. Because the accelerator is impedance matched throughout, capacitor energy is delivered to the strip-line load with an efficiency as high as 50%. We used an iterative finite element method (FEM, circuit, and magnetohydrodynamic simulations to develop an optimized accelerator design. When powered by 96 bricks, Thor delivers as much as 4.1 MA to a load, and achieves peak magnetic pressures as high as 65 GPa. When powered by 288 bricks, Thor delivers as much as 6.9 MA to a load, and achieves magnetic pressures as high as 170 GPa. We have developed an algebraic calculational procedure that uses the single brick basis function to determine the brick-triggering sequence necessary to generate a highly tailored current pulse time history for shockless loading of samples. Thor will drive a wide variety of magnetically driven shockless ramp compression, shockless flyer plate, shock-ramp, equation of state, material strength, phase transition, and other advanced material physics experiments.

  2. Width-modulated square-wave pulses for ultrasound applications.

    Science.gov (United States)

    Smith, Peter R; Cowell, David M J; Freear, Steven

    2013-11-01

    A method of output pressure control for ultrasound transducers using switched excitation is described. The method generates width-modulated square-wave pulse sequences that are suitable for driving ultrasound transducers using MOSFETs or similar devices. Sequences are encoded using an optimized level-shifted, carrier-comparison, pulse-width modulation (PWM) strategy derived from existing PWM theory, and modified specifically for ultrasound applications. The modifications are: a reduction in carrier frequency so that the smallest number of pulses are generated and minimal switching is necessary; alteration of a linear carrier form to follow a trigonometric relationship in accordance with the expected fundamental output; and application of frequency modulation to the carrier when generating frequency-modulated, amplitude- tapered signals. The PWM method permits control of output pressure for arbitrary waveform sequences at diagnostic frequencies (approximately 5 MHz) when sampled at 100 MHz, and is applicable to pulse shaping and array apodization. Arbitrary waveform generation capability is demonstrated in simulation using convolution with a transducer's impulse response, and experimentally with hydrophone measurement. Benefits in coded imaging are demonstrated when compared with fixed-width square-wave (pseudo-chirp) excitation in coded imaging, including reduction in image artifacts and peak side-lobe levels for two cases, showing 10 and 8 dB reduction in peak side-lobe level experimentally, compared with 11 and 7 dB reduction in simulation. In all cases, the experimental observations correlate strongly with simulated data.

  3. Pulse Dispersion in Phased Arrays

    Directory of Open Access Journals (Sweden)

    Randy L. Haupt

    2017-01-01

    Full Text Available Phased array antennas cause pulse dispersion when receiving or transmitting wideband signals, because phase shifting the signals does not align the pulse envelopes from the elements. This paper presents two forms of pulse dispersion that occur in a phased array antenna. The first results from the separation distance between the transmit and receive antennas and impacts the definition of far field in the time domain. The second is a function of beam scanning and array size. Time delay units placed at the element and/or subarrays limit the pulse dispersion.

  4. Analysis of Pulse Modulated Control Systems (Ⅲ) Stability of Systems with Pulse Frequency Modulation and Systems with Combined Pulse Frequency and Pulse Width Modulation

    OpenAIRE

    OI,Shigemitsu

    1993-01-01

    Sufficient conditions for finite pulse stability of interconnected systems with combined pulse frequency and pulse width modulation are developed in this paper using a direct method. The stability criteria established provide upper bounds on the number of pulses emitted by each modulator. The results are also applicable to those systems which contain a finite number of pulse frequency modulators and a finite number of combined pulse frequency and pulse width modulators

  5. Laser-induced periodic surface structures on fused silica upon cross-polarized two-color double-fs-pulse irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Höhm, S., E-mail: hoehm@mbi-berlin.de.de [Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie (MBI), Max-Born-Straße 2A, D-12489 Berlin (Germany); Herzlieb, M.; Rosenfeld, A. [Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie (MBI), Max-Born-Straße 2A, D-12489 Berlin (Germany); Krüger, J. [BAM Bundesanstalt für Materialforschung und–prüfung, Unter den Eichen 87, D-12205 Berlin (Germany); Bonse, J., E-mail: joern.bonse@bam.de [BAM Bundesanstalt für Materialforschung und–prüfung, Unter den Eichen 87, D-12205 Berlin (Germany)

    2015-05-01

    Graphical abstract: - Highlights: • LIPSS formation on fused silica is studied upon cross-polarized two-color (400 and 800 nm) double-fs-pulse irradiation. • LIPSS orientation follows the polarization of the first pulse. • LIPSS periods are determined by the wavelength of the first pulse. • LIPSS area is increased for temporally overlapping pulses due to nonlinear absorption. - Abstract: The dynamics of the formation of laser-induced periodic surface structures (LIPSS) on fused silica upon irradiation with linearly polarized fs-laser pulses (50 fs pulse duration) is studied by cross-polarized two-color double-fs-pulse experiments. In order to analyze the relevance of temporally distributed energy deposition in the early stage of LIPSS formation, a Mach-Zehnder interferometer was used for generating multiple double-pulse sequences at two different wavelengths (400 and 800 nm). The inter-pulse delay between the individual cross-polarized pulses of each sequence was systematically varied in the sub-ps range and the resulting LIPSS morphologies were characterized by scanning electron microscopy. It is found that the polarization of the first laser pulse arriving to the surface determines the orientation and the periodicity of the LIPSS. These two-color experiments further confirm the importance of the ultrafast energy deposition to the silica surface for LIPSS formation, particularly by the first laser pulse of each sequence. The second laser pulse subsequently reinforces the previously seeded spatial LIPSS characteristics (period, orientation)

  6. Demonstration of Two-Atom Entanglement with Ultrafast Optical Pulses

    Science.gov (United States)

    Wong-Campos, J. D.; Moses, S. A.; Johnson, K. G.; Monroe, C.

    2017-12-01

    We demonstrate quantum entanglement of two trapped atomic ion qubits using a sequence of ultrafast laser pulses. Unlike previous demonstrations of entanglement mediated by the Coulomb interaction, this scheme does not require confinement to the Lamb-Dicke regime and can be less sensitive to ambient noise due to its speed. To elucidate the physics of an ultrafast phase gate, we generate a high entanglement rate using just ten pulses, each of ˜20 ps duration, and demonstrate an entangled Bell state with (76 ±1 )% fidelity. These results pave the way for entanglement operations within a large collection of qubits by exciting only local modes of motion.

  7. Pulse-shaping strategies in short-pulse fiber amplifiers

    Energy Technology Data Exchange (ETDEWEB)

    Schimpf, Damian Nikolaus

    2010-02-09

    Ultrashort pulse lasers are an important tool in scientific and industrial applications. However, many applications are demanding higher average powers from these ultrashort pulse sources. This can be achieved by combining direct diode pumping with novel gain media designs. In particular, ultrashort pulse fiber lasers are now delivering average powers in the kW range. However, the design of fiber lasers, producing pulses with high peak-powers, is challenging due to the impact of nonlinear effects. To significantly reduce these detrimental effects in ultrashort pulse fiber amplifers, the combination of chirped pulse amplification (CPA) and large mode area fibers is employed. Using these methods, the pulse energy of fiber lasers has been steadily increasing for the past few years. Recently, a fiber-based CPA-system has been demonstrated which produces pulse energies of around 1 mJ. However, both the stretching and the enlargement of the mode area are limited, and therefore, the impact of nonlinearity is still noticed in systems employing such devices. The aim of this thesis is the analysis of CPA-systems operated beyond the conventional nonlinear limit, which corresponds to accumulated nonlinear phase-shifts around 1 rad. This includes a detailed discussion of the influence of the nonlinear effect self-phase modulation on the output pulse of CPA-systems. An analytical model is presented. Emphasis is placed on the design of novel concepts to control the impact of self-phase modulation. Pulse-shaping is regarded as a powerful tool to accomplish this goal. Novel methods to control the impact of SPM are experimentally demonstrated. The design of these concepts is based on the theoretical findings. Both amplitude- and phase-shaping are studied. Model-based phase-shaping is implemented in a state-of-the-art fiber CPA-system. The influence of the polarization state is also highlighted. Additionally, existing techniques and recent advances are put into context. (orig.)

  8. Pulsed depressed collector

    Energy Technology Data Exchange (ETDEWEB)

    Kemp, Mark A

    2015-11-03

    A high power RF device has an electron beam cavity, a modulator, and a circuit for feed-forward energy recovery from a multi-stage depressed collector to the modulator. The electron beam cavity include a cathode, an anode, and the multi-stage depressed collector, and the modulator is configured to provide pulses to the cathode. Voltages of the electrode stages of the multi-stage depressed collector are allowed to float as determined by fixed impedances seen by the electrode stages. The energy recovery circuit includes a storage capacitor that dynamically biases potentials of the electrode stages of the multi-stage depressed collector and provides recovered energy from the electrode stages of the multi-stage depressed collector to the modulator. The circuit may also include a step-down transformer, where the electrode stages of the multi-stage depressed collector are electrically connected to separate taps on the step-down transformer.

  9. Nanofabrication with Pulsed Lasers

    Directory of Open Access Journals (Sweden)

    Kabashin AV

    2010-01-01

    Full Text Available Abstract An overview of pulsed laser-assisted methods for nanofabrication, which are currently developed in our Institute (LP3, is presented. The methods compass a variety of possibilities for material nanostructuring offered by laser–matter interactions and imply either the nanostructuring of the laser-illuminated surface itself, as in cases of direct laser ablation or laser plasma-assisted treatment of semiconductors to form light-absorbing and light-emitting nano-architectures, as well as periodic nanoarrays, or laser-assisted production of nanoclusters and their controlled growth in gaseous or liquid medium to form nanostructured films or colloidal nanoparticles. Nanomaterials synthesized by laser-assisted methods have a variety of unique properties, not reproducible by any other route, and are of importance for photovoltaics, optoelectronics, biological sensing, imaging and therapeutics.

  10. Capacitor discharge pulse analysis.

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Michael Sean; Griffiths, Stewart K.; Tanner, Danelle Mary

    2013-08-01

    Capacitors used in firing sets and other high discharge current applications are discharge tested to verify performance of the capacitor against the application requirements. Parameters such as capacitance, inductance, rise time, pulse width, peak current and current reversal must be verified to ensure that the capacitor will meet the application needs. This report summarizes an analysis performed on the discharge current data to extract these parameters by fitting a second-order system model to the discharge data and using this fit to determine the resulting performance metrics. Details of the theory and implementation are presented. Using the best-fit second-order system model to extract these metrics results in less sensitivity to noise in the measured data and allows for direct extraction of the total series resistance, inductance, and capacitance.

  11. High repetition rate tunable femtosecond pulses and broadband amplification from fiber laser pumped parametric amplifier.

    Science.gov (United States)

    Andersen, T V; Schmidt, O; Bruchmann, C; Limpert, J; Aguergaray, C; Cormier, E; Tünnermann, A

    2006-05-29

    We report on the generation of high energy femtosecond pulses at 1 MHz repetition rate from a fiber laser pumped optical parametric amplifier (OPA). Nonlinear bandwidth enhancement in fibers provides the intrinsically synchronized signal for the parametric amplifier. We demonstrate large tunability extending from 700 nm to 1500 nm of femtosecond pulses with pulse energies as high as 1.2 muJ when the OPA is seeded by a supercontinuum generated in a photonic crystal fiber. Broadband amplification over more than 85 nm is achieved at a fixed wavelength. Subsequent compression in a prism sequence resulted in 46 fs pulses. With an average power of 0.5 W these pulses have a peak-power above 10 MW. In particular, the average power and pulse energy scalability of both involved concepts, the fiber laser and the parametric amplifier, will enable easy up-scaling to higher powers.

  12. High-power widely tunable sub-20 fs Gaussian laser pulses for ultrafast nonlinear spectroscopy.

    Science.gov (United States)

    Metzger, Bernd; Steinmann, Andy; Giessen, Harald

    2011-11-21

    We demonstrate the generation of widely tunable sub-20 fs Gaussian-shaped laser pulses using a grating-based 4-f pulse shaper and a liquid crystal spatial light modulator. Our pump source is an Yb:KGW solitary mode-locked oscillator at 44 MHz repetition rate which is coupled into a large mode area microstructured fiber to generate a broad spectrum from below 900 nm to above 1150 nm. These pulses are precompressed by a prism sequence and subsequently sent into the pulse shaper. We use the multiphoton intrapulse interference phase scan (MIIPS) for phase shaping and iterative amplitude optimization to achieve Gaussian-like tunable sub-20 fs pulses with output powers of up to 142 mW as well as nontunable pulses with 310 mW output power as short as 11.5 fs. © 2011 Optical Society of America

  13. NMR in pulsed magnetic field

    KAUST Repository

    Abou-Hamad, Edy

    2011-09-01

    Nuclear magnetic resonance (NMR) experiments in pulsed magnetic fields up to 30.4 T focused on 1H and 93Nb nuclei are reported. Here we discuss the advantage and limitation of pulsed field NMR and why this technique is able to become a promising research tool. © 2011 Elsevier Inc. All Rights Reserved.

  14. Electrode cartridge for pulse welding

    Energy Technology Data Exchange (ETDEWEB)

    Bonnen, John Joseph Francis; Golovashchenko, Sergey Fedorovich; Mamutov, Alexander; Maison, Lloyd Douglas

    2017-06-14

    A cartridge assembly for a tool includes a cartridge body or casing that contains a conductor. A conductor is connected to a pulse generator or source of stored charge that is discharged to vaporize the conductor and create an electro-hydraulic or electro-magnetic shockwave that is used to impact or pulse weld two parts together.

  15. Pulse Characteristic Curves of Vidicons,

    Science.gov (United States)

    microamps, and in vidicons with heterotransition screens, up to 10 microamps. The use of static modulation characteristic curves of vidicons for the...determination of the pulse beam current can lead to an error > 100%. With the help of pulse-modulation characteristic curves, it is possible to obtain the

  16. Microstructural musical linguistics: composers' pulses are liked most by the best musicians.

    Science.gov (United States)

    Clynes, M

    1995-06-01

    Western music is a combination of notated structure plus microstructure. Composers' pulses, as precise microstructural functions, were tested with five groups of subjects of graded musical proficiency: (1) 10 famous artists including Vladimir Ashkenazy, Yehudi Menuhin, Paul Badura-Skoda and others; (2) 14 Julliard School of Music graduate students; (3) 19 Manhattan School of Music graduate students; (4) 51 Australian conservatory students; and (5) 41 non-music students (total, 135 subjects). Composers' pulses consist of combined amplitude and timing warps specific to each composer--the composer's pulse matrix. Each subject listened to and scored 40 versions of 10 short music examples (not selected by the author) of eight bars each, composed by Beethoven, Mozart, Haydn and Schubert, performed by computer, in which composers' pulses, as developed by Clynes (1983, 1985a,b, 1986, 1987), were incorporated in a two-level hierarchic pulse configuration, and interchanged. Each example was heard with the pulses of those four composers in turn, in quasi-random sequence, one performance thus incorporating the "right" pulse and three the "wrong" ones. Results show dramatically that the greater the musical proficiency, the more marked the preference for the "right" pulse (p help non-musicians also to better understand composers' pulses. A theory of music as a double stream is introduced. The results suggest that the composers' pulse matrices posited by Clynes as a first approximation are in fact appropriately meaningful. Brain function aspects of the meaningful discrimination of such tiny time differences are discussed.

  17. Pulse shaping using a spatial light modulator

    CSIR Research Space (South Africa)

    Botha, N

    2009-07-01

    Full Text Available Femtosecond pulse shaping can be done by different kinds of pulse shapers, such as liquid crystal spatial light modulators (LC SLM), acousto optic modulators (AOM) and deformable and movable mirrors. A few applications where pulse shaping...

  18. Pulse position modulation for compact all-fiber vehicle laser rangefinder development

    Science.gov (United States)

    Mao, Xuesong; Cheng, Yongzhi; Xiong, Ying; Inoue, Daisuke; Kagami, Manabu

    2017-10-01

    We propose a method for developing small all-fiber vehicle laser rangefinders that is based on pulse position modulation (PPM) and data integration and present a theoretical study on its performance. Compared with spatial coupling, which is employed by most of the current commercial vehicle laser rangefinders, fiber coupling has the advantage that it can guide laser echoes into the interior of a car, so the electronic components following the photodiode can operate in a moderate-temperature environment. However, optical fibers have numerical apertures (NAs), which means that a laser beam from a receiving lens cannot be coupled into an optical fiber if its incident angle exceeds the critical value. Therefore, the effective size of the receiving lens is typically small since it is limited by its focal length and the NA of the fiber, causing the power of the laser echoes gathered by the receiving lens to be insufficient for performing target identification. Instead of increasing the peak transmitting laser power unrestrictedly, PPM and data integration effectively compensate for the low signal-to-noise ratio that results from the effective receiving lens size reduction. We validated the proposed method by conducting numerical simulations and performance analysis. Finally, we compared the proposed method with pseudorandom noise (PN) code modulation and found that, although the two methods perform equally well in single-target measurement scenarios, PPM is more effective than PN code modulation for multitarget measurement. In addition, PPM enables the transmission of laser beams with higher peak powers and requires less computation than PN code modulation does.

  19. Pulse source requirements for OTDM systems

    DEFF Research Database (Denmark)

    Clausen, Anders; Poulsen, Henrik Nørskov; Oxenløwe, Leif Katsuo

    2003-01-01

    A simulation model for investigating the impact of incoherent crosstalk due to pulse tail overlapping is proposed. Requirements to pulse width and pulse tail extinction ratio introducing a maximum of 1 dB penalty is extracted.......A simulation model for investigating the impact of incoherent crosstalk due to pulse tail overlapping is proposed. Requirements to pulse width and pulse tail extinction ratio introducing a maximum of 1 dB penalty is extracted....

  20. Bomb pulse biology

    Energy Technology Data Exchange (ETDEWEB)

    Falso, Miranda J. Sarachine [Center for Accelerator Mass Spectrometry, Mail Stop L-397, Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, CA 94551 (United States); Buchholz, Bruce A., E-mail: buchholz2@llnl.gov [Center for Accelerator Mass Spectrometry, Mail Stop L-397, Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, CA 94551 (United States)

    2013-01-15

    The past decade has seen an explosion in use of the {sup 14}C bomb pulse to do fundamental cell biology. Studies in the 1960s used decay counting to measure tissue turnover when the atmospheric {sup 14}C/C concentration was changing rapidly. Today bulk tissue measurements are of marginal interest since most of the carbon in the tissue resides in proteins, lipids and carbohydrates that turn over rapidly. Specific cell types with specialized functions are the focus of cell turnover investigations. Tissue samples need to be fresh or frozen. Fixed or preserved samples contain petroleum-derived carbon that has not been successfully removed. Cell or nuclear surface markers are used to sort specific cell types, typically by fluorescence-activated cell sorting (FACS). Specific biomolecules need to be isolated with high purity and accelerator mass spectrometry (AMS) measurements must accommodate samples that generally contain less than 40 {mu}g of carbon. Furthermore, all separations must not add carbon to the sample. Independent means such as UV absorbance must be used to confirm molecule purity. Approaches for separating specific proteins and DNA and combating contamination of undesired molecules are described.

  1. [Dynamic pulse signal acquisition and processing].

    Science.gov (United States)

    Zhang, Aihua; Chou, Yongxin

    2012-03-01

    In order to obtain and process pulse signal in real-time, the integer coefficients notch, low-pass filters and an envelope filtering method were designed in consideration of the characteristics of disturbances in pulse signal and then were verified by MATLAB. The pulse signal was processed on DSP in time domain and frequency domain after simplifying the programming. The pulse wave height and pulse rate were calculated in real-time, and the pulse signal's spectrum was illustrated by FFT. The results show that the filters can effectively suppress the interference in pulse signal, and the system can detect and analyze the dynamic pulse signal in real-time.

  2. Pulsed ultrasonic stir welding method

    Science.gov (United States)

    Ding, R. Jeffrey (Inventor)

    2013-01-01

    A method of performing ultrasonic stir welding uses a welding head assembly to include a plate and a rod passing through the plate. The rod is rotatable about a longitudinal axis thereof. In the method, the rod is rotated about its longitudinal axis during a welding operation. During the welding operation, a series of on-off ultrasonic pulses are applied to the rod such that they propagate parallel to the rod's longitudinal axis. At least a pulse rate associated with the on-off ultrasonic pulses is controlled.

  3. Pulsed light and pulsed electric field for foods and eggs.

    Science.gov (United States)

    Dunn, J

    1996-09-01

    Two new technologies for use in the food industry are described. The first method discussed uses intense pulse of light. This pulsed light (PureBright) process uses short duration flashes of broad spectrum "white" light to kill all exposed microorganisms, including vegetative bacteria, microbial and fungal spores, viruses, and protozoan oocysts. Each pulse, or flash, of light lasts only a few hundred millionths of a second (i.e., a few hundred microseconds). The intensity of each flash of light is about 20,000 times the intensity of sunlight at the earth's surface. The flashes are typically applied at a rate of about one to tens of flashes per second. For most applications, a few flashes applied in a fraction of a second provide an effective treatment. High microbial kill can be achieved, for example, on the surfaces of packaging materials, on packaging and processing equipment, foods, and medical devices as well as on many other surfaces. In addition, some bulk materials such as water and air that allow penetration of the light can be sterilized. The results of tests to measure the effects of pulsed light on Salmonella enteritiditis on eggs are presented. The second method discussed uses multiple, short duration, high intensity electric field pulses to kill vegetative microorganisms in pumpable products. This pulsed electric field (or CoolPure) process can be applied at modest temperatures at which no appreciable thermal damage occurs and the original taste, color, texture, and functionality of products can be retained.

  4. Design of spectral-spatial phase prewinding pulses and their use in small-tip fast recovery steady-state imaging.

    Science.gov (United States)

    Williams, Sydney N; Nielsen, Jon-Fredrik; Fessler, Jeffrey A; Noll, Douglas C

    2017-07-03

    Spectrally selective "prewinding" radiofrequency pulses can counteract B0 inhomogeneity in steady-state sequences, but can only prephase a limited range of off-resonance. We propose spectral-spatial small-tip angle prewinding pulses that increase the off-resonance bandwidth that can be successfully prephased by incorporating spatially tailored excitation patterns. We present a feasibility study to compare spectral and spectral-spatial prewinding pulses. These pulses add a prephasing term to the target magnetization pattern that aims to recover an assigned off-resonance bandwidth at the echo time. For spectral-spatial pulses, the design bandwidth is centered at the off-resonance frequency for each spatial location in a field map. We use these pulses in the small-tip fast recovery steady-state sequence, which is similar to balanced steady-state free precession. We investigate improvement of spectral-spatial pulses over spectral pulses using simulations and small-tip fast recovery scans of a gel phantom and human brain. In simulation, spectral-spatial pulses yielded lower normalized root mean squared excitation error than spectral pulses. For both experiments, the spectral-spatial pulse images are also qualitatively better (more uniform, less signal loss) than the spectral pulse images. Spectral-spatial prewinding pulses can prephase over a larger range of off-resonance than their purely spectral counterparts. Magn Reson Med, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  5. Localized wave pulses in the keyport experiment

    Energy Technology Data Exchange (ETDEWEB)

    Chambers, D.H.; Lewis, D.K.

    1998-02-17

    Localized wave (LW) pulses were produced using a standard Navy array in the anechoic tank at Navy Underwater Weapons Center (NUWC) Keyport. The LW pulses used were the MPS pulse first derived by Ziolkowski, and a new type of pulse based on a superposition of Gaussian beam modes. This new type is motivated by a desire to make a comparison of the MPS pulse with another broad band pulse built from solutions to the wave equation. The superposed Gaussian pulse can be described by parameters which are analogous to those describing the MPS pulse. We compare the directivity patternsand the axial energy decay between the pulses. We find the behavior of the pulses to be similar so that the superposed Gaussian could be another candidate in the class of low diffractive pulses known as localized waves.

  6. Luminal pulse velocity in a superluminal medium

    Science.gov (United States)

    Amano, Heisuke; Tomita, Makoto

    2015-12-01

    To investigate the physical meaning of pulse peak in fast and slow light media, we investigated propagation of differently shaped pulses experimentally, controlling the sharpness of the pulse peak. Symmetric behavior with respect to fast and slow light was observed in traditional Gaussian pulses; that is, propagated pulses were advanced or delayed, respectively, whereas the pulse shape remained unchanged. This symmetry broke down when the pulse peak was sharpened; in the fast light medium, the sharp pulse peak propagated with luminal velocity, and the transmitted pulse deformed into a characteristic asymmetric profile. In contrast, in the slow light medium, a time-delayed smooth peak appeared with a bending point at t =0 . This symmetry breaking with respect to fast and slow light is a universal characteristic of pulse propagation in causal dispersive systems. The sharp pulse peak can be recognized as a bending nonanalytical point and may be capable of transferring information.

  7. A pulsed magnetic stress applied to Drosophila melanogaster flies

    Science.gov (United States)

    Delle Side, D.; Bozzetti, M. P.; Friscini, A.; Giuffreda, E.; Nassisi, V.; Specchia, V.; Velardi, L.

    2014-04-01

    We report the development of a system to feed pulsed magnetic stress to biological samples. The device is based on a RLC circuit that transforms the energy stored in a high voltage capacitor into a magnetic field inside a coil. The field has been characterized and we found that charging the capacitor with 24 kV results in a peak field of 0.4 T. In order to test its effect, we applied such a stress to the Drosophila melanogaster model and we examined its bio-effects. We analysed, in the germ cells, the effects on the control of specific DNA repetitive sequences that are activated after different environmental stresses. The deregulation of these sequences causes genomic instability and chromosomes breaks leading to sterility. The magnetic field treatment did not produce effects on repetitive sequences in the germ cells of Drosophila. Hence, this field doesn't produce deleterious effects linked to repetitive sequences derepression.

  8. Pulse oximetry for perioperative monitoring

    DEFF Research Database (Denmark)

    Pedersen, Tom; Nicholson, Amanda; Hovhannisyan, Karen

    2014-01-01

    of hypoxaemia reduce morbidity and mortality in the perioperative period.3. Use of pulse oximetry per se reduces morbidity and mortality in the perioperative period.4. Use of pulse oximetry reduces unplanned respiratory admissions to the intensive care unit (ICU), decreases the length of ICU readmission or both....... SEARCH METHODS: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (2013, Issue 5), MEDLINE (1966 to June 2013), EMBASE (1980 to June 2013), CINAHL (1982 to June 2013), ISI Web of Science (1956 to June 2013), LILACS (1982 to June 2013) and databases of ongoing trials; we also....... Results indicated that hypoxaemia was reduced in the pulse oximetry group, both in the operating theatre and in the recovery room. During observation in the recovery room, the incidence of hypoxaemia in the pulse oximetry group was 1.5 to three times less. Postoperative cognitive function was independent...

  9. All about Heart Rate (Pulse)

    Science.gov (United States)

    ... result of taking a drug such as a beta blocker . A lower heart rate is also common for ... 100. Medication use: Meds that block your adrenaline (beta blockers) tend to slow your pulse, while too much ...

  10. Next generation Chirped Pulse Amplification

    Energy Technology Data Exchange (ETDEWEB)

    Nees, J.; Biswal, S.; Mourou, G. [Univ. Michigan, Center for Ultrafast Optical Science, Ann Arbor, MI (United States); Nishimura, Akihiko; Takuma, Hiroshi

    1998-03-01

    The limiting factors of Chirped Pulse Amplification (CPA) are discussed and experimental results of CPA in Yb:glass regenerative amplifier are given. Scaling of Yb:glass to the petawatt level is briefly discussed. (author)

  11. Pulsed ultrasonic stir welding system

    Science.gov (United States)

    Ding, R. Jeffrey (Inventor)

    2013-01-01

    An ultrasonic stir welding system includes a welding head assembly having a plate and a rod passing through the plate. The rod is rotatable about a longitudinal axis thereof. During a welding operation, ultrasonic pulses are applied to the rod as it rotates about its longitudinal axis. The ultrasonic pulses are applied in such a way that they propagate parallel to the longitudinal axis of the rod.

  12. Pulsed feedback defers cellular differentiation.

    Directory of Open Access Journals (Sweden)

    Joe H Levine

    2012-01-01

    Full Text Available Environmental signals induce diverse cellular differentiation programs. In certain systems, cells defer differentiation for extended time periods after the signal appears, proliferating through multiple rounds of cell division before committing to a new fate. How can cells set a deferral time much longer than the cell cycle? Here we study Bacillus subtilis cells that respond to sudden nutrient limitation with multiple rounds of growth and division before differentiating into spores. A well-characterized genetic circuit controls the concentration and phosphorylation of the master regulator Spo0A, which rises to a critical concentration to initiate sporulation. However, it remains unclear how this circuit enables cells to defer sporulation for multiple cell cycles. Using quantitative time-lapse fluorescence microscopy of Spo0A dynamics in individual cells, we observed pulses of Spo0A phosphorylation at a characteristic cell cycle phase. Pulse amplitudes grew systematically and cell-autonomously over multiple cell cycles leading up to sporulation. This pulse growth required a key positive feedback loop involving the sporulation kinases, without which the deferral of sporulation became ultrasensitive to kinase expression. Thus, deferral is controlled by a pulsed positive feedback loop in which kinase expression is activated by pulses of Spo0A phosphorylation. This pulsed positive feedback architecture provides a more robust mechanism for setting deferral times than constitutive kinase expression. Finally, using mathematical modeling, we show how pulsing and time delays together enable "polyphasic" positive feedback, in which different parts of a feedback loop are active at different times. Polyphasic feedback can enable more accurate tuning of long deferral times. Together, these results suggest that Bacillus subtilis uses a pulsed positive feedback loop to implement a "timer" that operates over timescales much longer than a cell cycle.

  13. Artistic Representation with Pulsed Holography

    Science.gov (United States)

    Ishii, S.

    2013-02-01

    This thesis describes artistic representation through pulsed holography. One of the prevalent practical problems in making holograms is object movement. Any movement of the object or film, including movement caused by acoustic vibration, has the same fatal results. One way of reducing the chance of movement is by ensuring that the exposure is very quick; using a pulsed laser can fulfill this objective. The attractiveness of using pulsed laser is based on the variety of materials or objects that can be recorded (e.g., liquid material or instantaneous scene of a moving object). One of the most interesting points about pulsed holograms is that some reconstructed images present us with completely different views of the real world. For example, the holographic image of liquid material does not appear fluid; it looks like a piece of hard glass that would produce a sharp sound upon tapping. In everyday life, we are unfamiliar with such an instantaneous scene. On the other hand, soft-textured materials such as a feather or wool differ from liquids when observed through holography. Using a pulsed hologram, we can sense the soft touch of the object or material with the help of realistic three-dimensional (3-D) images. The images allow us to realize the sense of touch in a way that resembles touching real objects. I had the opportunity to use a pulsed ruby laser soon after I started to work in the field of holography in 1979. Since then, I have made pulsed holograms of activities, including pouring water, breaking eggs, blowing soap bubbles, and scattering feathers and popcorn. I have also created holographic art with materials and objects, such as silk fiber, fabric, balloons, glass, flowers, and even the human body. Whenever I create art, I like to present the spectator with a new experience in perception. Therefore, I would like to introduce my experimental artwork through those pulsed holograms.

  14. Optical pulses, lasers, measuring techniques

    CERN Document Server

    Früngel, Frank B A

    1965-01-01

    High Speed Pulse Technology: Volume II: Optical Pulses - Lasers - Measuring Techniques focuses on the theoretical and engineering problems that result from the capacitor discharge technique.This book is organized into three main topics: light flash production from a capacitive energy storage; signal transmission and ranging systems by capacitor discharges and lasers; and impulse measuring technique. This text specifically discusses the air spark under atmospheric conditions, industrial equipment for laser flashing, and claims for light transmitting system. The application of light impulse sign

  15. Pulsed laser ablation of copper

    Science.gov (United States)

    Jordan, R.; Cole, D.; Lunney, J. G.; Mackay, K.; Givord, D.

    1995-02-01

    The laser ablation of copper with a 532 nm, 6 ns laser has been investigated in the regime normally used for pulsed laser deposition. The ablation depth per pulse and the flux and energy distribution of the ions in the plume were measured and compared to the deposition rate as measured by a quartz microbalance. These measurements were compared with an analytic model of ablation via a laser sustained plasma. It is shown that self-sputtering of the growing film is significant.

  16. Main: Sequences [KOME

    Lifescience Database Archive (English)

    Full Text Available Sequences Amino Acid Sequence Amino Acid sequence of full length cDNA (Longest ORF) kome_ine_full_se...quence_amino_db.fasta.zip kome_ine_full_sequence_amino_db.zip kome_ine_full_sequence_amino_db ...

  17. The sequence of sequencers: The history of sequencing DNA

    Science.gov (United States)

    Heather, James M.; Chain, Benjamin

    2016-01-01

    Determining the order of nucleic acid residues in biological samples is an integral component of a wide variety of research applications. Over the last fifty years large numbers of researchers have applied themselves to the production of techniques and technologies to facilitate this feat, sequencing DNA and RNA molecules. This time-scale has witnessed tremendous changes, moving from sequencing short oligonucleotides to millions of bases, from struggling towards the deduction of the coding sequence of a single gene to rapid and widely available whole genome sequencing. This article traverses those years, iterating through the different generations of sequencing technology, highlighting some of the key discoveries, researchers, and sequences along the way. PMID:26554401

  18. Pseudorandom noise generators dedicated for acustic measurements

    OpenAIRE

    Español Espinar, Xavier

    2012-01-01

    [ANGLÈS] Study of the noise generators. Implementation software for the KISS Generator in C language and Matlab programm for probability density normalization. Analysis of different noise generator devices dedicated for acoustic measurements. [CASTELLÀ] Estudio de los generadores de ruido. Implementación software del Generador KISS en lenguaje C y progama en Matlab para la normalización de la densidad de probabilidad del generador anterior. Análisis empírico de diferentes dispositivos gene...

  19. Square pulse linear transformer driver

    Directory of Open Access Journals (Sweden)

    A. A. Kim

    2012-04-01

    Full Text Available The linear transformer driver (LTD technological approach can result in relatively compact devices that can deliver fast, high current, and high-voltage pulses straight out of the LTD cavity without any complicated pulse forming and pulse compression network. Through multistage inductively insulated voltage adders, the output pulse, increased in voltage amplitude, can be applied directly to the load. The usual LTD architecture [A. A. Kim, M. G. Mazarakis, V. A. Sinebryukhov, B. M. Kovalchuk, V. A. Vizir, S. N Volkov, F. Bayol, A. N. Bastrikov, V. G. Durakov, S. V. Frolov, V. M. Alexeenko, D. H. McDaniel, W. E. Fowler, K. LeCheen, C. Olson, W. A. Stygar, K. W. Struve, J. Porter, and R. M. Gilgenbach, Phys. Rev. ST Accel. Beams 12, 050402 (2009PRABFM1098-440210.1103/PhysRevSTAB.12.050402; M. G. Mazarakis, W. E. Fowler, A. A. Kim, V. A. Sinebryukhov, S. T. Rogowski, R. A. Sharpe, D. H. McDaniel, C. L. Olson, J. L. Porter, K. W. Struve, W. A. Stygar, and J. R. Woodworth, Phys. Rev. ST Accel. Beams 12, 050401 (2009PRABFM1098-440210.1103/PhysRevSTAB.12.050401] provides sine shaped output pulses that may not be well suited for some applications like z-pinch drivers, flash radiography, high power microwaves, etc. A more suitable power pulse would have a flat or trapezoidal (rising or falling top. In this paper, we present the design and first test results of an LTD cavity that generates such a type of output pulse by including within its circular array a number of third harmonic bricks in addition to the main bricks. A voltage adder made out of a square pulse cavity linear array will produce the same shape output pulses provided that the timing of each cavity is synchronized with the propagation of the electromagnetic pulse.

  20. River water remediation using pulsed corona, pulsed spark or ozonation

    Energy Technology Data Exchange (ETDEWEB)

    Izdebski, T.; Dors, M. [Polish Academy of Sciences, Szewalski Inst. of Fluid Flow Machiney, Fiszera (Poland). Centre for Plasma and Laser Engineering; Mizeraczyk, J. [Polish Academy of Sciences, Szewalski Inst. of Fluid Flow Machiney, Fiszera (Poland). Centre for Plasma and Laser Engineering; Gdynia Maritime Univ., Morska (Poland). Dept. of Marine Electronics

    2010-07-01

    The most common reason for epidemic formation is the pollution of surface and drinking water by wastewater bacteria. Pathogenic microorganisms that form the largest part of this are fecal bacteria, such as escherichia coli (E. coli). Wastewater treatment plants reduce the amount of the fecal bacteria by 1-3 orders of magnitude, depending on the initial number of bacteria. There is a lack of data on waste and drinking water purification by the electrohydraulic discharges method, which causes the destruction and inactivation of viruses, yeast, and bacteria. This paper investigated river water cleaning from microorganisms using pulsed corona, spark discharge and ozonization. The paper discussed the experimental setup and results. It was concluded that ozonization is the most efficient method of water disinfection as compared with pulsed spark and pulsed corona discharges. The pulsed spark discharge in water was capable of killing all microorganism similarly to ozonization, but with much lower energy efficiency. The pulsed corona discharge was found to be the less effective method of water disinfection. 21 refs., 4 figs.

  1. Whole Genome Sequencing

    Science.gov (United States)

    ... you want to learn. Search form Search Whole Genome Sequencing You are here Home Testing & Services Testing ... the full story, click here . What is whole genome sequencing? Whole genome sequencing is the mapping out ...

  2. Sequence Read Archive (SRA)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Sequence Read Archive (SRA) stores raw sequencing data from the next generation of sequencing platforms including Roche 454 GS System®, Illumina Genome...

  3. A multi-plane scout sequence using flash imaging.

    Science.gov (United States)

    Wright, S M; Wright, R M

    1988-01-01

    A new pulse sequence is presented for multi-plane imaging which simultaneously acquires images in the axial, coronal, and sagittal planes. Combined with FLASH imaging or other similar techniques, T1- and T2-weighted images in all three planes can be acquired in approximately 12 and 30 seconds, respectively. The sequence is easily implemented by modifying a multi-slice sequence to provide a rotation of gradient assignments between slice excitations. This sequence has been used extensively as a rapid "scout" scan. Several clinical examples are included.

  4. Single-chip pulse programmer for magnetic resonance imaging using a 32-bit microcontroller.

    Science.gov (United States)

    Handa, Shinya; Domalain, Thierry; Kose, Katsumi

    2007-08-01

    A magnetic resonance imaging (MRI) pulse programmer has been developed using a single-chip microcontroller (ADmicroC7026). The microcontroller includes all the components required for the MRI pulse programmer: a 32-bit RISC CPU core, 62 kbytes of flash memory, 8 kbytes of SRAM, two 32-bit timers, four 12-bit DA converters, and 40 bits of general purpose I/O. An evaluation board for the microcontroller was connected to a host personal computer (PC), an MRI transceiver, and a gradient driver using interface circuitry. Target (embedded) and host PC programs were developed to enable MRI pulse sequence generation by the microcontroller. The pulse programmer achieved a (nominal) time resolution of approximately 100 ns and a minimum time delay between successive events of approximately 9 micros. Imaging experiments using the pulse programmer demonstrated the effectiveness of our approach.

  5. Coordinate cytokine regulatory sequences

    Science.gov (United States)

    Frazer, Kelly A.; Rubin, Edward M.; Loots, Gabriela G.

    2005-05-10

    The present invention provides CNS sequences that regulate the cytokine gene expression, expression cassettes and vectors comprising or lacking the CNS sequences, host cells and non-human transgenic animals comprising the CNS sequences or lacking the CNS sequences. The present invention also provides methods for identifying compounds that modulate the functions of CNS sequences as well as methods for diagnosing defects in the CNS sequences of patients.

  6. A Quantitative Analysis of Pulsed Signals Emitted by Wild Bottlenose Dolphins.

    Directory of Open Access Journals (Sweden)

    Ana Rita Luís

    Full Text Available Common bottlenose dolphins (Tursiops truncatus, produce a wide variety of vocal emissions for communication and echolocation, of which the pulsed repertoire has been the most difficult to categorize. Packets of high repetition, broadband pulses are still largely reported under a general designation of burst-pulses, and traditional attempts to classify these emissions rely mainly in their aural characteristics and in graphical aspects of spectrograms. Here, we present a quantitative analysis of pulsed signals emitted by wild bottlenose dolphins, in the Sado estuary, Portugal (2011-2014, and test the reliability of a traditional classification approach. Acoustic parameters (minimum frequency, maximum frequency, peak frequency, duration, repetition rate and inter-click-interval were extracted from 930 pulsed signals, previously categorized using a traditional approach. Discriminant function analysis revealed a high reliability of the traditional classification approach (93.5% of pulsed signals were consistently assigned to their aurally based categories. According to the discriminant function analysis (Wilk's Λ = 0.11, F3, 2.41 = 282.75, P < 0.001, repetition rate is the feature that best enables the discrimination of different pulsed signals (structure coefficient = 0.98. Classification using hierarchical cluster analysis led to a similar categorization pattern: two main signal types with distinct magnitudes of repetition rate were clustered into five groups. The pulsed signals, here described, present significant differences in their time-frequency features, especially repetition rate (P < 0.001, inter-click-interval (P < 0.001 and duration (P < 0.001. We document the occurrence of a distinct signal type-short burst-pulses, and highlight the existence of a diverse repertoire of pulsed vocalizations emitted in graded sequences. The use of quantitative analysis of pulsed signals is essential to improve classifications and to better assess the

  7. Behavioral studies of the auditory discrimination of paired pulses with identical pulse spacings by a dolphin

    Science.gov (United States)

    Sukhoruchenko, M. N.

    2008-11-01

    For a bottlenose dolphin, the thresholds of discrimination of paired pulses with pulse spacings of 50 1000 μs and different peak values of the second pulse in the test pair are investigated. It is shown that the pair discrimination thresholds depend on both the absolute level of pulses and the ratio between the pulse levels in the standard pair. As the pulse delay in a pair increases, the thresholds monotonically decrease. A possibility of the paired pulse discrimination by the total energy of pulses in a pair is considered for the case of pulse delays both within the critical interval (300 μs) and beyond it.

  8. Pulsed Corona Discharge Generated By Marx Generator

    Science.gov (United States)

    Sretenovic, G. B.; Obradovic, B. M.; Kovacevic, V. V.; Kuraica, M. M.; Puric J.

    2010-07-01

    The pulsed plasma has a significant role in new environmental protection technologies. As a part of a pulsed corona system for pollution control applications, Marx type repetitive pulse generator was constructed and tested in arrangement with wire-plate corona reactor. We performed electrical measurements, and obtained voltage and current signals, and also power and energy delivered per pulse. Ozone formation by streamer plasma in air was chosen to monitor chemical activity of the pulsed corona discharge.

  9. Root-flipped multiband refocusing pulses.

    Science.gov (United States)

    Sharma, Anuj; Lustig, Michael; Grissom, William A

    2016-01-01

    To design low peak power multiband refocusing radiofrequency pulses, with application to simultaneous multislice spin echo MRI. Multiband Shinnar-Le Roux β polynomials were designed using convex optimization. A Monte Carlo algorithm was used to determine patterns of β polynomial root flips that minimized the peak power of the resulting refocusing pulses. Phase-matched multiband excitation pulses were also designed to obtain linear-phase spin echoes. Simulations compared the performance of the root-flipped pulses with time-shifted and phase-optimized pulses. Phantom and in vivo experiments at 7T validated the function of the root-flipped pulses and compared them to time-shifted spin echo signal profiles. Averaged across number of slices, time-bandwidth product, and slice separation, the root-flipped pulses have 46% shorter durations than time-shifted pulses with the same peak radiofrequency amplitude. Unlike time-shifted and phase-optimized pulses, the root-flipped pulses' excitation errors do not increase with decreasing band separation. Experiments showed that the root-flipped pulses excited the desired slices at the target locations, and that for equivalent slice characteristics, the shorter root-flipped pulses allowed shorter echo times, resulting in higher signal than time-shifted pulses. The proposed root-flipped multiband radiofrequency pulse design method produces low peak power pulses for simultaneous multislice spin echo MRI. © 2015 Wiley Periodicals, Inc.

  10. Pulse oximetry in pediatric practice.

    Science.gov (United States)

    Fouzas, Sotirios; Priftis, Kostas N; Anthracopoulos, Michael B

    2011-10-01

    The introduction of pulse oximetry in clinical practice has allowed for simple, noninvasive, and reasonably accurate estimation of arterial oxygen saturation. Pulse oximetry is routinely used in the emergency department, the pediatric ward, and in pediatric intensive and perioperative care. However, clinically relevant principles and inherent limitations of the method are not always well understood by health care professionals caring for children. The calculation of the percentage of arterial oxyhemoglobin is based on the distinct characteristics of light absorption in the red and infrared spectra by oxygenated versus deoxygenated hemoglobin and takes advantage of the variation in light absorption caused by the pulsatility of arterial blood. Computation of oxygen saturation is achieved with the use of calibration algorithms. Safe use of pulse oximetry requires knowledge of its limitations, which include motion artifacts, poor perfusion at the site of measurement, irregular rhythms, ambient light or electromagnetic interference, skin pigmentation, nail polish, calibration assumptions, probe positioning, time lag in detecting hypoxic events, venous pulsation, intravenous dyes, and presence of abnormal hemoglobin molecules. In this review we describe the physiologic principles and limitations of pulse oximetry, discuss normal values, and highlight its importance in common pediatric diseases, in which the principle mechanism of hypoxemia is ventilation/perfusion mismatch (eg, asthma exacerbation, acute bronchiolitis, pneumonia) versus hypoventilation (eg, laryngotracheitis, vocal cord dysfunction, foreign-body aspiration in the larynx or trachea). Additional technologic advancements in pulse oximetry and its incorporation into evidence-based clinical algorithms will improve the efficiency of the method in daily pediatric practice.

  11. Design, characterization and experimental validation of a compact, flexible pulsed power architecture for ex vivo platelet activation.

    Directory of Open Access Journals (Sweden)

    Allen L Garner

    Full Text Available Electric pulses can induce various changes in cell dynamics and properties depending upon pulse parameters; however, pulsed power generators for in vitro and ex vivo applications may have little to no flexibility in changing the pulse duration, rise- and fall-times, or pulse shape. We outline a compact pulsed power architecture that operates from hundreds of nanoseconds (with the potential for modification to tens of nanoseconds to tens of microseconds by modifying a Marx topology via controlling switch sequences and voltages into each capacitor stage. We demonstrate that this device can deliver pulses to both low conductivity buffers, like standard pulsed power supplies used for electroporation, and higher conductivity solutions, such as blood and platelet rich plasma. We further test the effectiveness of this pulse generator for biomedical applications by successfully activating platelets ex vivo with 400 ns and 600 ns electric pulses. This novel bioelectrics platform may provide researchers with unprecedented flexibility to explore a wide range of pulse parameters that may induce phenomena ranging from intracellular to plasma membrane manipulation.

  12. Design, characterization and experimental validation of a compact, flexible pulsed power architecture for ex vivo platelet activation.

    Science.gov (United States)

    Garner, Allen L; Caiafa, Antonio; Jiang, Yan; Klopman, Steve; Morton, Christine; Torres, Andrew S; Loveless, Amanda M; Neculaes, V Bogdan

    2017-01-01

    Electric pulses can induce various changes in cell dynamics and properties depending upon pulse parameters; however, pulsed power generators for in vitro and ex vivo applications may have little to no flexibility in changing the pulse duration, rise- and fall-times, or pulse shape. We outline a compact pulsed power architecture that operates from hundreds of nanoseconds (with the potential for modification to tens of nanoseconds) to tens of microseconds by modifying a Marx topology via controlling switch sequences and voltages into each capacitor stage. We demonstrate that this device can deliver pulses to both low conductivity buffers, like standard pulsed power supplies used for electroporation, and higher conductivity solutions, such as blood and platelet rich plasma. We further test the effectiveness of this pulse generator for biomedical applications by successfully activating platelets ex vivo with 400 ns and 600 ns electric pulses. This novel bioelectrics platform may provide researchers with unprecedented flexibility to explore a wide range of pulse parameters that may induce phenomena ranging from intracellular to plasma membrane manipulation.

  13. Operation and beam profiling of an up to 200 kHz pulse-burst laser for Thomson scattering

    Energy Technology Data Exchange (ETDEWEB)

    Young, W. C., E-mail: wcyoung2@wisc.edu; Den Hartog, D. J. [Department of Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706 (United States); Center for Magnetic Self-Organization in Laboratory and Astrophysical Plasmas, University of Wisconsin-Madison, Madison, Wisconsin 53706 (United States)

    2014-11-15

    A new, high-repetition rate laser is in development for use on the Thomson scattering diagnostic on the Madison Symmetric Torus. The laser has been tested at a rate of 200 kHz in a pulse-burst operation, producing bursts of 5 pulses above 1.5 J each, while capable of bursts of 17 pulses at 100 kHz. A master oscillator-power amplifier architecture is used with a Nd:YVO{sub 4} oscillator, four Nd:YAG amplifiers, and a Nd:glass amplifier. A radial profile over the pulse sequence is measured by using a set of graphite apertures and an energy meter, showing a change in beam quality over a pulsing sequence.

  14. Radial flow pulse jet mixer

    Science.gov (United States)

    VanOsdol, John G.

    2013-06-25

    The disclosure provides a pulse jet mixing vessel for mixing a plurality of solid particles. The pulse jet mixing vessel is comprised of a sludge basin, a flow surface surrounding the sludge basin, and a downcoming flow annulus between the flow surface and an inner shroud. The pulse jet mixing vessel is additionally comprised of an upper vessel pressurization volume in fluid communication with the downcoming flow annulus, and an inner shroud surge volume separated from the downcoming flow annulus by the inner shroud. When the solid particles are resting on the sludge basin and a fluid such as water is atop the particles and extending into the downcoming flow annulus and the inner shroud surge volume, mixing occurs by pressurization of the upper vessel pressurization volume, generating an inward radial flow over the flow surface and an upwash jet at the center of the sludge basin.

  15. Decoding sequence learning from single-trial intracranial EEG in humans.

    Directory of Open Access Journals (Sweden)

    Marzia De Lucia

    Full Text Available We propose and validate a multivariate classification algorithm for characterizing changes in human intracranial electroencephalographic data (iEEG after learning motor sequences. The algorithm is based on a Hidden Markov Model (HMM that captures spatio-temporal properties of the iEEG at the level of single trials. Continuous intracranial iEEG was acquired during two sessions (one before and one after a night of sleep in two patients with depth electrodes implanted in several brain areas. They performed a visuomotor sequence (serial reaction time task, SRTT using the fingers of their non-dominant hand. Our results show that the decoding algorithm correctly classified single iEEG trials from the trained sequence as belonging to either the initial training phase (day 1, before sleep or a later consolidated phase (day 2, after sleep, whereas it failed to do so for trials belonging to a control condition (pseudo-random sequence. Accurate single-trial classification was achieved by taking advantage of the distributed pattern of neural activity. However, across all the contacts the hippocampus contributed most significantly to the classification accuracy for both patients, and one fronto-striatal contact for one patient. Together, these human intracranial findings demonstrate that a multivariate decoding approach can detect learning-related changes at the level of single-trial iEEG. Because it allows an unbiased identification of brain sites contributing to a behavioral effect (or experimental condition at the level of single subject, this approach could be usefully applied to assess the neural correlates of other complex cognitive functions in patients implanted with multiple electrodes.

  16. Producing High Intense Attosecond Pulse Train by Interaction of Three-Color Pulse and Overdense Plasma

    Science.gov (United States)

    Salehi, M.; Mirzanejad, S.

    2017-05-01

    Amplifying the attosecond pulse by the chirp pulse amplification method is impossible. Furthermore, the intensity of attosecond pulse is low in the interaction of laser pulse and underdense plasma. This motivates us to propose using a multi-color pulse to produce the high intense attosecond pulse. In the present study, the relativistic interaction of a three-color linearly-polarized laser-pulse with highly overdense plasma is studied. We show that the combination of {{ω }}1, {{ω }}2 and {{ω }}3 frequencies decreases the instance full width at half maximum reflected attosecond pulse train from the overdense plasma surface. Moreover, we show that the three-color pulse increases the intensity of generated harmonics, which is explained by the relativistic oscillating mirror model. The obtained results demonstrate that if the three-color laser pulse interacts with overdense plasma, it will enhance two orders of magnitude of intensity of ultra short attosecond pulses in comparison with monochromatic pulse.

  17. High power ultrashort pulse lasers

    Energy Technology Data Exchange (ETDEWEB)

    Perry, M.D.

    1994-10-07

    Small scale terawatt and soon even petawatt (1000 terawatt) class laser systems are made possible by application of the chirped-pulse amplification technique to solid-state lasers combined with the availability of broad bandwidth materials. These lasers make possible a new class of high gradient accelerators based on the large electric fields associated with intense laser-plasma interactions or from the intense laser field directly. Here, we concentrate on the laser technology to produce these intense pulses. Application of the smallest of these systems to the production of high brightness electron sources is also introduced.

  18. Pulse compressor with aberration correction

    Energy Technology Data Exchange (ETDEWEB)

    Mankos, Marian [Electron Optica, Inc., Palo Alto, CA (United States)

    2015-11-30

    In this SBIR project, Electron Optica, Inc. (EOI) is developing an electron mirror-based pulse compressor attachment to new and retrofitted dynamic transmission electron microscopes (DTEMs) and ultrafast electron diffraction (UED) cameras for improving the temporal resolution of these instruments from the characteristic range of a few picoseconds to a few nanoseconds and beyond, into the sub-100 femtosecond range. The improvement will enable electron microscopes and diffraction cameras to better resolve the dynamics of reactions in the areas of solid state physics, chemistry, and biology. EOI’s pulse compressor technology utilizes the combination of electron mirror optics and a magnetic beam separator to compress the electron pulse. The design exploits the symmetry inherent in reversing the electron trajectory in the mirror in order to compress the temporally broadened beam. This system also simultaneously corrects the chromatic and spherical aberration of the objective lens for improved spatial resolution. This correction will be found valuable as the source size is reduced with laser-triggered point source emitters. With such emitters, it might be possible to significantly reduce the illuminated area and carry out ultrafast diffraction experiments from small regions of the sample, e.g. from individual grains or nanoparticles. During phase I, EOI drafted a set of candidate pulse compressor architectures and evaluated the trade-offs between temporal resolution and electron bunch size to achieve the optimum design for two particular applications with market potential: increasing the temporal and spatial resolution of UEDs, and increasing the temporal and spatial resolution of DTEMs. Specialized software packages that have been developed by MEBS, Ltd. were used to calculate the electron optical properties of the key pulse compressor components: namely, the magnetic prism, the electron mirror, and the electron lenses. In the final step, these results were folded

  19. High-speed pulse techniques

    CERN Document Server

    Coekin, J A

    1975-01-01

    High-Speed Pulse Techniques covers the many aspects of technique in digital electronics and encompass some of the more fundamental factors that apply to all digital systems. The book describes the nature of pulse signals and their deliberate or inadvertent processing in networks, transmission lines and transformers, and then examines the characteristics and transient performance of semiconductor devices and integrated circuits. Some of the problems associated with the assembly of these into viable systems operating at ultra high speed are also looked at. The book examines the transients and w

  20. 35 Volt, 180 Ampere Pulse Generator with Droop Control for Pulsing Xenon Arcs

    DEFF Research Database (Denmark)

    Hviid, T.; Nielsen, S. O.

    1972-01-01

    The pulse generator described works as a combined switch and series current regulator and allows the shape of the current pulse to be adjusted at each optical wavelength to produce a flat pulse of monochromatic light.......The pulse generator described works as a combined switch and series current regulator and allows the shape of the current pulse to be adjusted at each optical wavelength to produce a flat pulse of monochromatic light....

  1. Dynamic Characterization of Fiber Optical Chirped Pulse Amplification for Sub-ps Pulses

    DEFF Research Database (Denmark)

    Cristofori, Valentina; Lali-Dastjerdi, Zohreh; Rishøj, Lars Søgaard

    2013-01-01

    We investigate experimentally the propagation of sub-picosecond pulses in fiber optical parametric chirped pulse amplifiers, showing a significant broadening of the pulses from 450 fs up to 720 fs due to dispersion and self-phase modulation.......We investigate experimentally the propagation of sub-picosecond pulses in fiber optical parametric chirped pulse amplifiers, showing a significant broadening of the pulses from 450 fs up to 720 fs due to dispersion and self-phase modulation....

  2. Testing a scale pulsed modulator for an IEC neutron source into a resistive load

    Energy Technology Data Exchange (ETDEWEB)

    Dale, Gregory E [Los Alamos National Laboratory; Wheat, Robert M [Los Alamos National Laboratory; Aragonez, Robert [Los Alamos National Laboratory

    2009-01-01

    A 1/10th scaled prototype pulse modulator for an Inertial Electrostatic Confinement (IEC) neutron source has been designed and tested at Los Alamos National Laboratory (LANL). The scaled prototype modulator is based on a solid-state Marx architecture and has an output voltage of 13 kV and an output current of 10 A. The modulator has a variable pulse width between 50 {micro}s and 1 ms with < 5% droop at all pulse widths. The modulator operates with a duty factor up to 5% and has a maximum pulse repetition frequency of 1 kHz. The use of a solid-state Marx modulator in this application has several potential benefits. These benefits include variable pulse width and amplitude, inherent switch overcurrent and transient overvoltage protection, and increased efficiency over DC supplies used in this application. Several new features were incorporated into this design including inductorless charging, fully snubberless operation, and stage fusing. The scaled prototype modulator has been tested using a 1 k{Omega} resistive load. Test results are given. Short (50 {micro}s) and long (1 ms) pulses are demonstrated as well as high duty factor operation (1 kHz rep rate at a 50 {micro}s pulse width for a 5% duty factor). Pulse agility of the modulator is demonstrated through turning the individual Marx stages on and off in sequence producing ramp, pyramid, and reverse pyramid waveforms.

  3. Single-photon technique for the detection of periodic extraterrestrial laser pulses.

    Science.gov (United States)

    Leeb, W R; Poppe, A; Hammel, E; Alves, J; Brunner, M; Meingast, S

    2013-06-01

    To draw humankind's attention to its existence, an extraterrestrial civilization could well direct periodic laser pulses toward Earth. We developed a technique capable of detecting a quasi-periodic light signal with an average of less than one photon per pulse within a measurement time of a few tens of milliseconds in the presence of the radiation emitted by an exoplanet's host star. Each of the electronic events produced by one or more single-photon avalanche detectors is tagged with precise time-of-arrival information and stored. From this we compute a histogram displaying the frequency of event-time differences in classes with bin widths on the order of a nanosecond. The existence of periodic laser pulses manifests itself in histogram peaks regularly spaced at multiples of the-a priori unknown-pulse repetition frequency. With laser sources simulating both the pulse source and the background radiation, we tested a detection system in the laboratory at a wavelength of 850 nm. We present histograms obtained from various recorded data sequences with the number of photons per pulse, the background photons per pulse period, and the recording time as main parameters. We then simulated a periodic signal hypothetically generated on a planet orbiting a G2V-type star (distance to Earth 500 light-years) and show that the technique is capable of detecting the signal even if the received pulses carry as little as one photon on average on top of the star's background light.

  4. Femtosecond pulse shaping using the geometric phase.

    Science.gov (United States)

    Gökce, Bilal; Li, Yanming; Escuti, Michael J; Gundogdu, Kenan

    2014-03-15

    We demonstrate a femtosecond pulse shaper that utilizes polarization gratings to manipulate the geometric phase of an optical pulse. This unique approach enables circular polarization-dependent shaping of femtosecond pulses. As a result, it is possible to create coherent pulse pairs with orthogonal polarizations in a 4f pulse shaper setup, something until now that, to our knowledge, was only achieved via much more complex configurations. This approach could be used to greatly simplify and enhance the functionality of multidimensional spectroscopy and coherent control experiments, in which multiple coherent pulses are used to manipulate quantum states in materials of interest.

  5. Pulse image recognition using fuzzy neural network.

    Science.gov (United States)

    Xu, L S; Meng, Max Q -H; Wang, K Q

    2007-01-01

    The automatic recognition of pulse images is the key in the research of computerized pulse diagnosis. In order to automatically differentiate the pulse patterns by using small samples, a fuzzy neural network to classify pulse images based on the knowledge of experts in traditional Chinese pulse diagnosis was designed. The designed classifier can make hard decision and soft decision for identifying 18 patterns of pulse images at the accuracy of 91%, which is better than the results that achieved by back-propagation neural network.

  6. Polynomially Bounded Sequences and Polynomial Sequences

    Directory of Open Access Journals (Sweden)

    Okazaki Hiroyuki

    2015-09-01

    Full Text Available In this article, we formalize polynomially bounded sequences that plays an important role in computational complexity theory. Class P is a fundamental computational complexity class that contains all polynomial-time decision problems [11], [12]. It takes polynomially bounded amount of computation time to solve polynomial-time decision problems by the deterministic Turing machine. Moreover we formalize polynomial sequences [5].

  7. Wave equations for pulse propagation

    Science.gov (United States)

    Shore, B. W.

    1987-06-01

    Theoretical discussions of the propagation of pulses of laser radiation through atomic or molecular vapor rely on a number of traditional approximations for idealizing the radiation and the molecules, and for quantifying their mutual interaction by various equations of propagation (for the radiation) and excitation (for the molecules). In treating short-pulse phenomena it is essential to consider coherent excitation phenomena of the sort that is manifest in Rabi oscillations of atomic or molecular populations. Such processes are not adequately treated by rate equations for excitation nor by rate equations for radiation. As part of a more comprehensive treatment of the coupled equations that describe propagation of short pulses, this memo presents background discussion of the equations that describe the field. This memo discusses the origin, in Maxwell's equations, of the wave equation used in the description of pulse propagation. It notes the separation into lamellar and solenoidal (or longitudinal and transverse) and positive and negative frequency parts. It mentions the possibility of separating the polarization field into linear and nonlinear parts, in order to define a susceptibility or index of refraction and, from these, a phase and group velocity.

  8. Anaesthetic Monitoring - the Pulse Oximeter

    African Journals Online (AJOL)

    the pulse oximeter: 1. It is a teaching tool showing the physiology of oxygen delivery. 2. It is especially useful to evaluate the efficacy of oxygen therapy during recovery from an- aesthesia and surgery and on the ward. 3. It shows when tracheal intubation is too slow. It shows when the tube is in the wrong place or blocked or ...

  9. Atomic collisions involving pulsed positrons

    DEFF Research Database (Denmark)

    Merrison, J. P.; Bluhme, H.; Field, D.

    2000-01-01

    instantaneous intensities be achieved with in-beam accumulation, but more importantly many orders of magnitude improvement in energy and spatial resolution can be achieved using positron cooling. Atomic collisions can be studied on a new energy scale with unprecedented precion and control. The use...... of accelerators for producing intense positron pulses will be discussed in the context of atomic physics experiments....

  10. Pulses and waves of contractility.

    Science.gov (United States)

    Wu, Min

    2017-12-04

    The nature of signal transduction networks in the regulation of cell contractility is not entirely clear. In this study, Graessl et al. (2017. J. Cell Biol. https://doi.org/10.1083/jcb.201706052) visualized and characterized pulses and waves of Rho activation in adherent cells and proposed excitable Rho signaling networks underlying cell contractility. © 2017 Wu.

  11. Broadband excitation in solid-state NMR using interleaved DANTE pulse trains with N pulses per rotor period.

    Science.gov (United States)

    Lu, Xingyu; Trébosc, Julien; Lafon, Olivier; Carnevale, Diego; Ulzega, Simone; Bodenhausen, Geoffrey; Amoureux, Jean-Paul

    2013-11-01

    We analyze the direct excitation of wide one-dimensional spectra of nuclei with spin I=1/2 or 1 in rotating solids submitted to pulse trains in the manner of Delays Alternating with Nutations for Tailored Excitation (DANTE), either with one short rotor-synchronized pulse of duration τp in each of K rotor periods (D1(K)) or with N interleaved equally spaced pulses τp in each rotor period, globally also extending over K rotor periods (D(N)(K)). The excitation profile of D(N)(K) scheme is a comb of rf-spikelets with Nν(R)=N/T(R) spacing from the carrier frequency, and a width of each spikelet inversely proportional to the length, KT(R), of D(N)(K) scheme. Since the individual pulse lengths, τp, are typically of a few hundreds of ns, D(N)(K) scheme can readily excite spinning sidebands families covering several MHz, provided the rf carrier frequency is close enough to the resonance frequency of one the spinning sidebands. If the difference of isotropic chemical shifts between distinct chemical sites is less than about 1.35/(KT(R)), D(N)(K) scheme can excite the spinning sidebands families of several sites. For nuclei with I=1/2, if the homogeneous and inhomogeneous decays of coherences during the DANTE sequence are neglected, the K pulses of a D1(K) train have a linearly cumulative effect, so that the total nutation angle is θ(tot)=K2πν1τp, where ν1 is the rf-field amplitude. This allows obtaining nearly ideal 90° pulses for excitation or 180° rotations for inversion and refocusing across wide MAS spectra comprising many spinning sidebands. If one uses interleaved DANTE trains D(N)(K) with N>1, only spinning sidebands separated by intervals of Nν(R) with respect to the carrier frequency are observed as if the effective spinning speed was Nν(R). The other sidebands have vanishing intensities because of the cancellation of the N contributions with opposite signs. However, the intensities of the remaining sidebands obey the same rules as in spectra obtained

  12. Cryosurgery with Pulsed Electric Fields

    Science.gov (United States)

    Daniels, Charlotte S.; Rubinsky, Boris

    2011-01-01

    This study explores the hypothesis that combining the minimally invasive surgical techniques of cryosurgery and pulsed electric fields will eliminate some of the major disadvantages of these techniques while retaining their advantages. Cryosurgery, tissue ablation by freezing, is a well-established minimally invasive surgical technique. One disadvantage of cryosurgery concerns the mechanism of cell death; cells at high subzero temperature on the outer rim of the frozen lesion can survive. Pulsed electric fields (PEF) are another minimally invasive surgical technique in which high strength and very rapid electric pulses are delivered across cells to permeabilize the cell membrane for applications such as gene delivery, electrochemotherapy and irreversible electroporation. The very short time scale of the electric pulses is disadvantageous because it does not facilitate real time control over the procedure. We hypothesize that applying the electric pulses during the cryosurgical procedure in such a way that the electric field vector is parallel to the heat flux vector will have the effect of confining the electric fields to the frozen/cold region of tissue, thereby ablating the cells that survive freezing while facilitating controlled use of the PEF in the cold confined region. A finite element analysis of the electric field and heat conduction equations during simultaneous tissue treatment with cryosurgery and PEF (cryosurgery/PEF) was used to study the effect of tissue freezing on electric fields. The study yielded motivating results. Because of decreased electrical conductivity in the frozen/cooled tissue, it experienced temperature induced magnified electric fields in comparison to PEF delivered to the unfrozen tissue control. This suggests that freezing/cooling confines and magnifies the electric fields to those regions; a targeting capability unattainable in traditional PEF. This analysis shows how temperature induced magnified and focused PEFs could be used to

  13. Cryosurgery with pulsed electric fields.

    Directory of Open Access Journals (Sweden)

    Charlotte S Daniels

    Full Text Available This study explores the hypothesis that combining the minimally invasive surgical techniques of cryosurgery and pulsed electric fields will eliminate some of the major disadvantages of these techniques while retaining their advantages. Cryosurgery, tissue ablation by freezing, is a well-established minimally invasive surgical technique. One disadvantage of cryosurgery concerns the mechanism of cell death; cells at high subzero temperature on the outer rim of the frozen lesion can survive. Pulsed electric fields (PEF are another minimally invasive surgical technique in which high strength and very rapid electric pulses are delivered across cells to permeabilize the cell membrane for applications such as gene delivery, electrochemotherapy and irreversible electroporation. The very short time scale of the electric pulses is disadvantageous because it does not facilitate real time control over the procedure. We hypothesize that applying the electric pulses during the cryosurgical procedure in such a way that the electric field vector is parallel to the heat flux vector will have the effect of confining the electric fields to the frozen/cold region of tissue, thereby ablating the cells that survive freezing while facilitating controlled use of the PEF in the cold confined region. A finite element analysis of the electric field and heat conduction equations during simultaneous tissue treatment with cryosurgery and PEF (cryosurgery/PEF was used to study the effect of tissue freezing on electric fields. The study yielded motivating results. Because of decreased electrical conductivity in the frozen/cooled tissue, it experienced temperature induced magnified electric fields in comparison to PEF delivered to the unfrozen tissue control. This suggests that freezing/cooling confines and magnifies the electric fields to those regions; a targeting capability unattainable in traditional PEF. This analysis shows how temperature induced magnified and focused

  14. Wave equations for pulse propagation

    Energy Technology Data Exchange (ETDEWEB)

    Shore, B.W.

    1987-06-24

    Theoretical discussions of the propagation of pulses of laser radiation through atomic or molecular vapor rely on a number of traditional approximations for idealizing the radiation and the molecules, and for quantifying their mutual interaction by various equations of propagation (for the radiation) and excitation (for the molecules). In treating short-pulse phenomena it is essential to consider coherent excitation phenomena of the sort that is manifest in Rabi oscillations of atomic or molecular populations. Such processes are not adequately treated by rate equations for excitation nor by rate equations for radiation. As part of a more comprehensive treatment of the coupled equations that describe propagation of short pulses, this memo presents background discussion of the equations that describe the field. This memo discusses the origin, in Maxwell's equations, of the wave equation used in the description of pulse propagation. It notes the separation into lamellar and solenoidal (or longitudinal and transverse) and positive and negative frequency parts. It mentions the possibility of separating the polarization field into linear and nonlinear parts, in order to define a susceptibility or index of refraction and, from these, a phase and group velocity. The memo discusses various ways of characterizing the polarization characteristics of plane waves, that is, of parameterizing a transverse unit vector, such as the Jones vector, the Stokes vector, and the Poincare sphere. It discusses the connection between macroscopically defined quantities, such as the intensity or, more generally, the Stokes parameters, and microscopic field amplitudes. The material presented here is a portion of a more extensive treatment of propagation to be presented separately. The equations presented here have been described in various books and articles. They are collected here as a summary and review of theory needed when treating pulse propagation.

  15. Flash X-ray sources powered by Blumlein pulse generators

    Science.gov (United States)

    Davanloo, F.; Coogan, J. J.; Krause, R. K.; Bhawalkar, J. D.; Collins, C. B.

    1991-05-01

    Described here is the progress in construction and characterization of pulse-power generators capable of discharging at high repetition rates. These devices consist of several triaxial Blumleins stacked in series at one end. The lines are charged in parallel and synchronously commuted with a single thyratron at the other end. In this way relatively low charging voltages are multiplied to give the desired discharge voltage without the need for complex Marx bank circuitry. Scaling of these stacked Blumlein generators to obtain open circuit voltages in excess of 0.5 MV is reported. Peak power generated by discharging into an X-ray diode exceeds 10 7 R/s and high repetition rates allow for an average emitted X-ray exposure rate of 25 R/s from a sequence of 40 ns pulses.

  16. Linear transformer driver for pulse generation

    Science.gov (United States)

    Kim, Alexander A; Mazarakis, Michael G; Sinebryukhov, Vadim A; Volkov, Sergey N; Kondratiev, Sergey S; Alexeenko, Vitaly M; Bayol, Frederic; Demol, Gauthier; Stygar, William A

    2015-04-07

    A linear transformer driver includes at least one ferrite ring positioned to accept a load. The linear transformer driver also includes a first power delivery module that includes a first charge storage devices and a first switch. The first power delivery module sends a first energy in the form of a first pulse to the load. The linear transformer driver also includes a second power delivery module including a second charge storage device and a second switch. The second power delivery module sends a second energy in the form of a second pulse to the load. The second pulse has a frequency that is approximately three times the frequency of the first pulse. The at least one ferrite ring is positioned to force the first pulse and the second pulse to the load by temporarily isolating the first pulse and the second pulse from an electrical ground.

  17. Coherent combining pulse bursts in time domain

    Energy Technology Data Exchange (ETDEWEB)

    Galvanauskas, Almantas

    2018-01-09

    A beam combining and pulse stacking technique is provided that enhances laser pulse energy by coherent stacking pulse bursts (i.e. non-periodic pulsed signals) in time domain. This energy enhancement is achieved by using various configurations of Fabry-Perot, Gires-Tournois and other types of resonant cavities, so that a multiple-pulse burst incident at either a single input or multiple inputs of the system produces an output with a solitary pulse, which contains the summed energy of the incident multiple pulses from all beams. This disclosure provides a substantial improvement over conventional coherent-combining methods in that it achieves very high pulse energies using a relatively small number of combined laser systems, thus providing with orders of magnitude reduction in system size, complexity, and cost compared to current combining approaches.

  18. Peak holding circuit for extremely narrow pulses

    Science.gov (United States)

    Oneill, R. W. (Inventor)

    1975-01-01

    An improved pulse stretching circuit comprising: a high speed wide-band amplifier connected in a fast charge integrator configuration; a holding circuit including a capacitor connected in parallel with a discharging network which employs a resistor and an FET; and an output buffer amplifier. Input pulses of very short duration are applied to the integrator charging the capacitor to a value proportional to the input pulse amplitude. After a predetermined period of time, conventional circuitry generates a dump pulse which is applied to the gate of the FET making a low resistance path to ground which discharges the capacitor. When the dump pulse terminates, the circuit is ready to accept another pulse to be stretched. The very short input pulses are thus stretched in width so that they may be analyzed by conventional pulse height analyzers.

  19. Genome Sequence Databases (Overview): Sequencing and Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Lapidus, Alla L.

    2009-01-01

    From the date its role in heredity was discovered, DNA has been generating interest among scientists from different fields of knowledge: physicists have studied the three dimensional structure of the DNA molecule, biologists tried to decode the secrets of life hidden within these long molecules, and technologists invent and improve methods of DNA analysis. The analysis of the nucleotide sequence of DNA occupies a special place among the methods developed. Thanks to the variety of sequencing technologies available, the process of decoding the sequence of genomic DNA (or whole genome sequencing) has become robust and inexpensive. Meanwhile the assembly of whole genome sequences remains a challenging task. In addition to the need to assemble millions of DNA fragments of different length (from 35 bp (Solexa) to 800 bp (Sanger)), great interest in analysis of microbial communities (metagenomes) of different complexities raises new problems and pushes some new requirements for sequence assembly tools to the forefront. The genome assembly process can be divided into two steps: draft assembly and assembly improvement (finishing). Despite the fact that automatically performed assembly (or draft assembly) is capable of covering up to 98% of the genome, in most cases, it still contains incorrectly assembled reads. The error rate of the consensus sequence produced at this stage is about 1/2000 bp. A finished genome represents the genome assembly of much higher accuracy (with no gaps or incorrectly assembled areas) and quality ({approx}1 error/10,000 bp), validated through a number of computer and laboratory experiments.

  20. Pulsed lasers in speckle photography: error owing to pulse width.

    Science.gov (United States)

    Joenathan, C; Blair, S M; Ganesan, A R

    1993-01-10

    The effect of the pulse width of a pulsed laser in the studies of speckle velocimetry and transient vibration analysis is discussed. Because of the motion of the object during an exposure, a sine function is obtained by using the pointwise filtering method. This function modulates the halo along with the Young's fringes. It is shown that for high object velocities the sinc function modifies the halo distribution; as a result, the error in calculating the fringe position increases. An aperture geometry for which the autocorrelation halo is made constant in certain regions is proposed in which the intensity variation in this region is the result of the modulating sinc function only. A closed-form solution for the shift in the position of the fringes in this region is obtained. Experimental results of the simulation are presented.

  1. Sensors and Methods for Electromagnetic Pulse Identification

    OpenAIRE

    Pavel FIALA; Drexler, Petr

    2006-01-01

    There are some suitable methods for the measurement of ultra-short solitary electromagnetic pulses that can be generated by high power pulsed generators. The measurement methods properties have to correspond to the fact whether we want to measure pulses of voltage, current or free-space electromagnetic wave. The need for specific measurement methods occurred by the development of high power microwave pulse generator. Applicable methods are presented in this paper. The method utilizing Faraday...

  2. Automated DNA Sequencing System

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, G.A.; Ekkebus, C.P.; Hauser, L.J.; Kress, R.L.; Mural, R.J.

    1999-04-25

    Oak Ridge National Laboratory (ORNL) is developing a core DNA sequencing facility to support biological research endeavors at ORNL and to conduct basic sequencing automation research. This facility is novel because its development is based on existing standard biology laboratory equipment; thus, the development process is of interest to the many small laboratories trying to use automation to control costs and increase throughput. Before automation, biology Laboratory personnel purified DNA, completed cycle sequencing, and prepared 96-well sample plates with commercially available hardware designed specifically for each step in the process. Following purification and thermal cycling, an automated sequencing machine was used for the sequencing. A technician handled all movement of the 96-well sample plates between machines. To automate the process, ORNL is adding a CRS Robotics A- 465 arm, ABI 377 sequencing machine, automated centrifuge, automated refrigerator, and possibly an automated SpeedVac. The entire system will be integrated with one central controller that will direct each machine and the robot. The goal of this system is to completely automate the sequencing procedure from bacterial cell samples through ready-to-be-sequenced DNA and ultimately to completed sequence. The system will be flexible and will accommodate different chemistries than existing automated sequencing lines. The system will be expanded in the future to include colony picking and/or actual sequencing. This discrete event, DNA sequencing system will demonstrate that smaller sequencing labs can achieve cost-effective the laboratory grow.

  3. <3> OMEGA pulse-forming network

    CERN Multimedia

    1974-01-01

    Adjustement of the 3 W pulse-forming network of the SPS beam dumping system. When charged at 60 kV, this PFN gives 10 kA, 25 ms current pulses, with oscillations, superimposed on the pulse flat top, of an amplitude of +/- 1 Ka.

  4. A Study of New Pulse Auscultation System

    Directory of Open Access Journals (Sweden)

    Ying-Yun Chen

    2015-04-01

    Full Text Available This study presents a new type of pulse auscultation system, which uses a condenser microphone to measure pulse sound waves on the wrist, captures the microphone signal for filtering, amplifies the useful signal and outputs it to an oscilloscope in analog form for waveform display and storage and delivers it to a computer to perform a Fast Fourier Transform (FFT and convert the pulse sound waveform into a heartbeat frequency. Furthermore, it also uses an audio signal amplifier to deliver the pulse sound by speaker. The study observed the principles of Traditional Chinese Medicine’s pulsing techniques, where pulse signals at places called “cun”, “guan” and “chi” of the left hand were measured during lifting (100 g, searching (125 g and pressing (150 g actions. Because the system collects the vibration sound caused by the pulse, the sensor itself is not affected by the applied pressure, unlike current pulse piezoelectric sensing instruments, therefore, under any kind of pulsing pressure, it displays pulse changes and waveforms with the same accuracy. We provide an acquired pulse and waveform signal suitable for Chinese Medicine practitioners’ objective pulse diagnosis, thus providing a scientific basis for this Traditional Chinese Medicine practice. This study also presents a novel circuit design using an active filtering method. An operational amplifier with its differential features eliminates the interference from external signals, including the instant high-frequency noise. In addition, the system has the advantages of simple circuitry, cheap cost and high precision.

  5. Experiments on sediment pulses in mountain rivers

    Science.gov (United States)

    Y. Cui; T. E. Lisle; J. E. Pizzuto; G. Parker

    1998-01-01

    Pulses of sediment can be introduced into mountain rivers from such mechanisms as debris flows, landslides and fans at tributary confluences. These processes can be natural or associated with the activities of humans, as in the case of a pulse created by sediment derived from timber harvest or the removal of a dam. How does the river digest these pulses?

  6. Third Harmonic Imaging using a Pulse Inversion

    DEFF Research Database (Denmark)

    Rasmussen, Joachim; Du, Yigang; Jensen, Jørgen Arendt

    2011-01-01

    The pulse inversion (PI) technique can be utilized to separate and enhance harmonic components of a waveform for tissue harmonic imaging. While most ultrasound systems can perform pulse inversion, only few image the 3rd harmonic component. PI pulse subtraction can isolate and enhance the 3rd...

  7. High speed, high current pulsed driver circuit

    Science.gov (United States)

    Carlen, Christopher R.

    2017-03-21

    Various technologies presented herein relate to driving a LED such that the LED emits short duration pulses of light. This is accomplished by driving the LED with short duration, high amplitude current pulses. When the LED is driven by short duration, high amplitude current pulses, the LED emits light at a greater amplitude compared to when the LED is driven by continuous wave current.

  8. Double pulse Thomson scattering system at RTP

    NARCIS (Netherlands)

    Beurskens, M. N. A.; Barth, C. J.; Chu, C.C.; Donne, A. J. H.; Herranz, J. A.; Cardozo, N. J. L.; van der Meiden, H. J.; Pijper, F.J.

    1997-01-01

    In this article a double pulse multiposition Thomson scattering diagnostic, under construction at RTP, is discussed. Light from a double pulsed ruby laser (pulse separation: 10-800 mu s, max. 2x12.5 J) is scattered by the free electrons of the tokamak plasma and relayed to a Littrow polychromator

  9. The LHC Sequencer

    CERN Document Server

    Alemany-Fernandez, Reyes; Gorbonosov, Roman; Khasbulatov, Denis; Lamont, Mike; Le Roux, Pascal; Roderick, Chris

    2011-01-01

    The Large Hadron Collider (LHC) at CERN is a highly complex system made of many different sub-systems whose operation implies the execution of many tasks with stringent constraints on the order and duration of the execution. To be able to operate such a system in the most efficient and reliable way, the operators in the CERN control room use a high level control system: the LHC Sequencer. The LHC Sequencer system is composed of several components, including an Oracle database where operational sequences are configured, a core server that orchestrates the execution of the sequences, and two graphical user interfaces: one for sequence edition, and another for sequence execution. This paper describes the architecture of the LHC Sequencer system, and how the sequences are prepared and used for LHC operation.

  10. Anomaly Detection in Sequences

    Data.gov (United States)

    National Aeronautics and Space Administration — We present a set of novel algorithms which we call sequenceMiner, that detect and characterize anomalies in large sets of high-dimensional symbol sequences that...

  11. Roles of repetitive sequences

    Energy Technology Data Exchange (ETDEWEB)

    Bell, G.I.

    1991-12-31

    The DNA of higher eukaryotes contains many repetitive sequences. The study of repetitive sequences is important, not only because many have important biological function, but also because they provide information on genome organization, evolution and dynamics. In this paper, I will first discuss some generic effects that repetitive sequences will have upon genome dynamics and evolution. In particular, it will be shown that repetitive sequences foster recombination among, and turnover of, the elements of a genome. I will then consider some examples of repetitive sequences, notably minisatellite sequences and telomere sequences as examples of tandem repeats, without and with respectively known function, and Alu sequences as an example of interspersed repeats. Some other examples will also be considered in less detail.

  12. sequenceMiner algorithm

    Data.gov (United States)

    National Aeronautics and Space Administration — Detecting and describing anomalies in large repositories of discrete symbol sequences. sequenceMiner has been open-sourced! Download the file below to try it out....

  13. DNA sequencing conference, 2

    Energy Technology Data Exchange (ETDEWEB)

    Cook-Deegan, R.M. [Georgetown Univ., Kennedy Inst. of Ethics, Washington, DC (United States); Venter, J.C. [National Inst. of Neurological Disorders and Strokes, Bethesda, MD (United States); Gilbert, W. [Harvard Univ., Cambridge, MA (United States); Mulligan, J. [Stanford Univ., CA (United States); Mansfield, B.K. [Oak Ridge National Lab., TN (United States)

    1991-06-19

    This conference focused on DNA sequencing, genetic linkage mapping, physical mapping, informatics and bioethics. Several were used to study this sequencing and mapping. This article also discusses computer hardware and software aiding in the mapping of genes.

  14. Numerical and experimental study of an annular pulse tube used in the pulse tube cooler

    Science.gov (United States)

    Pang, Xiaomin; Chen, Yanyan; Wang, Xiaotao; Dai, Wei; Luo, Ercang

    2017-12-01

    Multi-stage pulse tube coolers normally use a U-type configuration. For compactness, it is attractive to build a completely co-axial multi-stage pulse tube cooler. In this way, an annular shape pulse tube is inevitable. Although there are a few reports about previous annular pulse tubes, a detailed study and comparison with a circular pulse tube is lacking. In this paper, a numeric model based on CFD software is carried out to compare the annular pulse tube and circular pulse tube used in a single stage in-line type pulse tube cooler with about 10 W of cooling power at 77 K. The length and cross sectional area of the two pulse tubes are kept the same. Simulation results show that the enthalpy flow in the annular pulse tube is lower by 1.6 W (about 11% of the enthalpy flow) compared to that in circular pulse tube. Flow and temperature distribution characteristics are also analyzed in detail. Experiments are then conducted for comparison with an in-line type pulse tube cooler. With the same acoustic power input, the pulse tube cooler with a circular pulse tube obtains 7.88 W of cooling power at 77 K, while using an annular pulse tube leads to a cooling power of 7.01 W, a decrease of 0.9 W (11.4%) on the cooling performance. The study sets the basis for building a completely co-axial two-stage pulse tube cooler.

  15. Patterns of digital volume pulse waveform and pulse transit time in ...

    African Journals Online (AJOL)

    Introduction: Arterial wall changes underlie many disorders of aging and the complications of diseases like hypertension and diabetes mellitus. Analyzing the pulse wave is an easy, noninvasive method used to assess vessel wall stiffness and pulse changes. In this study the digital volume pulse wave and the pulse transit ...

  16. Numerical and behavioral effects within a pulse-driven system: consequences for shared prey.

    Science.gov (United States)

    Schmidt, Kenneth A; Ostfeld, Richard S

    2008-03-01

    Some of the clearest examples of the ramifying effects of resource pulses exist in deciduous forests dominated by mast-producing trees, such as oaks, beech, and hornbeam. Seed production in these forests represents only the first of several pulsed events. Secondary pulses emerge as mast-consuming small rodents numerically respond to seed production and tertiary pulses emerge as generalist predators numerically respond to rodents. Raptors may also respond behaviorally (i.e., diet shifts) to subsequent crashes in small rodents following the crash phase in seed production. In oak-dominated forest in the Hudson Valley, New York, these various pulse and crash phases act synergistically, although not simultaneously, to influence thrush population dynamics through predation on nests, juveniles, and adults. As a consequence, factors limiting population growth rate and their age-specific action vary as a function of past acorn production. We highlight these interactions based on our eight-year study of thrush demography, acorn production, and small mammal abundance coupled with information on regional adult thrush population trends from the Breeding Bird Survey. We use these data sets to demonstrate the sequence of primary to tertiary pulses and how they influence breeding thrush populations. To extend our discussion beyond masting phenomena in the eastern United States, we briefly review the literature of alternative avian prey within pulsed systems to show (1) numerical and behavioral responses by generalist predators are ubiquitous in pulsed systems, and this contributes to (2) variability in reproduction and survivorship of avian prey linked to the underlying dynamics of the pulse. We conclude by exploring the broad consequences of cascading resource pulses for alternative prey based upon the indirect interaction of apparent competition among shared prey and the nature of temporal variability on populations.

  17. CW seeded optical parametric amplifier providing wavelength and pulse duration tunable nearly transform limited pulses.

    Science.gov (United States)

    Hädrich, S; Gottschall, T; Rothhardt, J; Limpert, J; Tünnermann, A

    2010-02-01

    An optical parametric amplifier that delivers nearly transform limited pulses is presented. The center wavelength of these pulses can be tuned between 993 nm and 1070 nm and, at the same time, the pulse duration is varied between 206 fs and 650 fs. At the shortest pulse duration the pulse energy was increased up to 7.2 microJ at 50 kHz repetition rate. Variation of the wavelength is achieved by applying a tunable cw seed while the pulse duration can be varied via altering the pump pulse duration. This scheme offers superior flexibility and scaling possibilities.

  18. Pulse Propagation on close conductors

    CERN Document Server

    Dieckmann, A

    2001-01-01

    The propagation and reflection of arbitrarily shaped pulses on non-dispersive parallel conductors of finite length with user defined cross section is simulated employing the discretized telegraph equation. The geometry of the system of conductors and the presence of dielectric material determine the capacities and inductances that enter the calculation. The values of these parameters are found using an iterative Laplace equation solving procedure and confirmed for certain calculable geometries including the line charge inside a box. The evolving pulses and the resulting crosstalk can be plotted at any instant and - in the Mathematica notebook version of this report - be looked at in an animation. As an example a differential pair of microstrips as used in the ATLAS vertex detector is analysed.

  19. Unsplit bipolar pulse forming line

    Science.gov (United States)

    Rhodes, Mark A [Pleasanton, CA

    2011-05-24

    A bipolar pulse forming transmission line module and system for linear induction accelerators having first, second, third, and fourth planar conductors which form a sequentially arranged interleaved stack having opposing first and second ends, with dielectric layers between the conductors. The first and second planar conductors are connected to each other at the first end, and the first and fourth planar conductors are connected to each other at the second end via a shorting plate. The third planar conductor is electrically connectable to a high voltage source, and an internal switch functions to short at the first end a high voltage from the third planar conductor to the fourth planar conductor to produce a bipolar pulse at the acceleration axis with a zero net time integral. Improved access to the switch is enabled by an aperture through the shorting plate and the proximity of the aperture to the switch.

  20. Sub-10 fs deep-ultraviolet pulses generated by chirped-pulse four-wave mixing.

    Science.gov (United States)

    Kida, Yuichiro; Liu, Jun; Teramoto, Takahiro; Kobayashi, Takayoshi

    2010-06-01

    We propose and demonstrate experimentally a novel way of generating sub-10fs deep-UV pulses. The technique is based on chirped-pulse four-wave mixing induced by a broadband near-IR (NIR) pulse and a near-UV pulse. The broadband IR pulse is prepared by preliminarily broadening the spectral width of an NIR pulse by self-phase modulation. The positively chirped broadband IR pulse is suitable for generating a negatively chirped deep-UV pulse, which can be compressed by normal group-velocity dispersion in a transparent medium. Self-compression of the generated deep-UV pulse in air has been demonstrated to produce sub-10fs deep-UV pulses with excellent temporal and spectral profiles for ultrafast spectroscopy in the deep UV.

  1. A new Pulse-Pattern Generator based on LabVIEW FPGA

    Energy Technology Data Exchange (ETDEWEB)

    Ziegler, F., E-mail: falk.ziegler@lab-coding.de [Institut fuer Physik, Ernst-Moritz-Arndt Universitaet Greifswald, 17489 Greifswald (Germany); Beck, D.; Brand, H.; Hahn, H. [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, 64291 Darmstadt (Germany); Marx, G.; Schweikhard, L. [Institut fuer Physik, Ernst-Moritz-Arndt Universitaet Greifswald, 17489 Greifswald (Germany)

    2012-07-01

    For the control of experimental sequences composed of triggers, gates and delays a Pulse-Pattern Generator (PPG) has been developed based on a Field Programmable Gate Array (FPGA) addressed in a LabVIEW environment. It allows a highly reproducible timing of measurement procedures by up to 64 individual channels with pulse and delay periods from the nanoseconds to the minutes range. The PPG has been implemented in the context of the development of a new control system for the ClusterTrap setup, an ion storage device for atomic-cluster research, in close contact with the SHIPTRAP and ISOLTRAP collaborations at GSI and CERN, respectively. As the new PPG is not ion-trap specific it can be employed in any experiment based on sequences of triggers, pulses and delays.

  2. Pulsed Scophony laser projection system

    Science.gov (United States)

    Lowry, J. B.; Welford, W. T.; Humphries, M. R.

    1988-10-01

    A novel laser TV projection display has been developed by PA Technology employing the Scophony system with acousto-optic modulators and pulsed lasers. This results in a projection system with greater optical simplicity, higher reliability and reduced power and cooling requirements over similar laser projectors. The technique has been successfully implemented in British Aerospace's Microdome missile training simulator. This paper describes the underlying principles of the design, its operational features and its implementation in the Microdome.

  3. Metal silicides with energetic pulses

    Science.gov (United States)

    D'Anna, E.; Leggieri, G.; Luches, A.; Majni, G.; Nava, F.; Ottaviani, G.

    1986-07-01

    Samples formed of a thin metal film deposited on silicon single crystal were annealed with electron and laser (ruby and excimer) pulses over a wide range of fluences. From a comparison of the experimental results with the temperature profiles of the irradiated samples, it turns out that suicide formation starts when the metal/silicon interface reaches the lowest eutectic temperature of the binary metal/silicon system. The growth rate of reacted layers is of the order of 1 m/s.

  4. Pulse amplitude modulated chlorophyll fluorometer

    Energy Technology Data Exchange (ETDEWEB)

    Greenbaum, Elias; Wu, Jie

    2015-12-29

    Chlorophyll fluorometry may be used for detecting toxins in a sample because of changes in micro algae. A portable lab on a chip ("LOAC") based chlorophyll fluorometer may be used for toxin detection and environmental monitoring. In particular, the system may include a microfluidic pulse amplitude modulated ("PAM") chlorophyll fluorometer. The LOAC PAM chlorophyll fluorometer may analyze microalgae and cyanobacteria that grow naturally in source drinking water.

  5. High Voltage Nanosecond Pulse Generator.

    Science.gov (United States)

    1978-11-01

    pulse to a laser load was desiqned , built , and tested . —- -~~~-~~~~----j ‘~ ~~ _)— ~ --. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ CoIx ~r 1 I

  6. Nine-channel mid-power bipolar pulse generator based on a field programmable gate array

    Energy Technology Data Exchange (ETDEWEB)

    Haylock, Ben, E-mail: benjamin.haylock2@griffithuni.edu.au; Lenzini, Francesco; Kasture, Sachin; Fisher, Paul; Lobino, Mirko [Centre for Quantum Dynamics, Griffith University, Brisbane (Australia); Queensland Micro and Nanotechnology Centre, Griffith University, Brisbane (Australia); Streed, Erik W. [Centre for Quantum Dynamics, Griffith University, Brisbane (Australia); Institute for Glycomics, Griffith University, Gold Coast (Australia)

    2016-05-15

    Many channel arbitrary pulse sequence generation is required for the electro-optic reconfiguration of optical waveguide networks in Lithium Niobate. Here we describe a scalable solution to the requirement for mid-power bipolar parallel outputs, based on pulse patterns generated by an externally clocked field programmable gate array. Positive and negative pulses can be generated at repetition rates up to 80 MHz with pulse width adjustable in increments of 1.6 ns across nine independent outputs. Each channel can provide 1.5 W of RF power and can be synchronised with the operation of other components in an optical network such as light sources and detectors through an external clock with adjustable delay.

  7. A blind transform based approach for the detection of isolated astrophysical pulses

    Science.gov (United States)

    Alkhweldi, Marwan; Schmid, Natalia A.; Prestage, Richard M.

    2017-06-01

    This paper presents a blind algorithm for the automatic detection of isolated astrophysical pulses. The detection algorithm is applied to spectrograms (also known as "filter bank data" or "the (t,f) plane"). The detection algorithm comprises a sequence of three steps: (1) a Radon transform is applied to the spectrogram, (2) a Fourier transform is applied to each projection parametrized by an angle, and the total power in each projection is calculated, and (3) the total power of all projections above 90° is compared to the total power of all projections below 90° and a decision in favor of an astrophysical pulse present or absent is made. Once a pulse is detected, its Dispersion Measure (DM) is estimated by fitting an analytically developed expression for a transformed spectrogram containing a pulse, with varying value of DM, to the actual data. The performance of the proposed algorithm is numerically analyzed.

  8. Generation of synchronized signal and pump pulses for an optical ...

    Indian Academy of Sciences (India)

    2015-11-27

    pass geometry in a grating pair based pulse stretcher unit. The pump pulse has been further amplified in a high gain regenerative amplifier. This amplified pulse was used as the pump in an optical parametric chirped pulse ...

  9. Electromagnetic pulses bone healing booster

    Science.gov (United States)

    Sintea, S. R.; Pomazan, V. M.; Bica, D.; Grebenisan, D.; Bordea, N.

    2015-11-01

    Posttraumatic bone restoration triggered by the need to assist and stimulate compensatory bone growth in periodontal condition. Recent studies state that specific electromagnetic stimulation can boost the bone restoration, reaching up to 30% decrease in recovery time. Based on the existing data on the electromagnetic parameters, a digital electronic device is proposed for intra oral mounting and bone restoration stimulation in periodontal condition. The electrical signal is applied to an inductive mark that will create and impregnate magnetic field in diseased tissue. The device also monitors the status of the electromagnetic field. Controlled wave forms and pulse frequency signal at programmable intervals are obtained with optimized number of components and miniaturized using surface mounting devices (SMD) circuits and surface mounting technology (SMT), with enhanced protection against abnormal current growth, given the intra-oral environment. The system is powered by an autonomous power supply (battery), to limit the problems caused by powering medical equipment from the main power supply. Currently the device is used in clinical testing, in cycles of six up to twelve months. Basic principles for the electrical scheme and algorithms for pulse generation, pulse control, electromagnetic field control and automation of current monitoring are presented, together with the friendly user interface, suitable for medical data and patient monitoring.

  10. Pure and Sn-doped ZnO films produced by pulsed laser deposition

    DEFF Research Database (Denmark)

    Holmelund, E.; Schou, Jørgen; Tougaard, S.

    2002-01-01

    A new technique, metronome doping, has been used for doping of films during pulsed laser deposition (PLD). This technique makes it possible to dope continuously during film growth with different concentrations of a dopant in one deposition sequence. Films of pure and doped ZnO have been produced...

  11. [Pulse triggering for improved diffusion-weighted MR imaging of the abdomen].

    Science.gov (United States)

    Mürtz, P; Pauleit, D; Träber, F; Gieseke, J; Kreft, B P; van den Brink, J S; Schild, H H

    2000-07-01

    The aim of this work was to reduce the influence of motion on diffusion-weighted MR images of the abdomen by pulse triggering of single-shot sequences. Five healthy volunteers were examined both without and with finger pulse-triggering of a diffusion-weighted single-shot echo planar MR imaging sequence at 1.5 T. Series of diffusion-weighted images were acquired at different phases of the cardiac cycle by varying the time delay between finger pulse and sequence acquisition. The measurements were repeated three times. The diffusion weighted images were analysed by measuring the signal intensities and by determining the ADC values within the spleen, kidney and liver. The magnitude of motion artifacts on diffusion weighted images shows a strong dependence on the trigger delay. The optimum trigger delay is found to be between 500 and 600 ms. For these values the abdominal organs appear homogeneous on all diffusion weighted images and the strongest signal intensities are detected. At optimum triggering the accuracy of the apparent diffusion coefficients is up to 10 times better than without triggering. Moreover, the standard deviation of the repeated measurements is smaller than 12% for all volunteers and for all organs. Without triggering the standard deviation is larger by a factor of 4 on average. Pulse triggering of single-shot sequences leads to significant reduction of motion related artifacts on diffusion weighted images of the abdomen and provides more accurate and reproducible ADC values.

  12. Pulse growth dynamics in laser mode locking

    Science.gov (United States)

    Popov, Mark; Gat, Omri

    2018-01-01

    We analyze theoretically and numerically the nonlinear process of pulse formation in mode-locked lasers, starting from a perturbation of a continuous wave. Focusing on weak-to-moderate dispersion systems, we show that pulse growth is initially slow, dominated by a cascade of energy from low to high axial modes, followed by fast strongly nonlinear growth, and finally relaxation to the stable pulse wave form. The pulse grows initially by condensing a fixed amount of energy into a decreasing time interval, with peak power growing toward a finite-time singularity that is checked when the gain bandwidth is saturated by the pulse.

  13. Slow light pulse propagation in dispersive media

    DEFF Research Database (Denmark)

    Nielsen, Torben Roland; Mørk, Jesper; Lavrinenko, Andrei

    2009-01-01

    We present a theoretical and numerical analysis of pulse propagation in a semiconductor photonic crystal waveguide with embedded quantum dots in a regime where the pulse is subjected to both waveguide and material dispersion. The group index and the transmission are investigated by finite...... broadening or break-up of the pulse may be observed. The transition from linear to nonlinear pulse propagation is quantified in terms of the spectral width of the pulse. To cite this article: T.R. Nielsen et al., C. R. Physique 10 (2009). (C) 2009 Academie des sciences. Published by Elsevier Masson SAS. All...

  14. Few-cycle pulse characterization with an acousto-optic pulse shaper.

    Science.gov (United States)

    Cousin, S L; Forget, N; Grün, A; Bates, P K; Austin, Dane R; Biegert, J

    2011-08-01

    An acousto-optic pulse shaper has been used to characterize few-cycle pulses generated in a hollow-core fiber. A grism pair precompensates for the dispersion of the acousto-optic crystal, allowing the full pulse-shaping window to be used for replica generation rather than self-compensation. A 9.4 fs pulse was measured, the shortest ever measured with an acousto-optic pulse shaper, to our knowledge. © 2011 Optical Society of America

  15. A New Active Cavitation Mapping Technique for Pulsed HIFU Applications – Bubble Doppler

    Science.gov (United States)

    Li, Tong; Khokhlova, Tatiana; Sapozhnikov, Oleg; Hwang, Joo Ha; Sapozhnikov, Oleg; O’Donnell, Matthew

    2015-01-01

    In this work, a new active cavitation mapping technique for pulsed high-intensity focused ultrasound (pHIFU) applications termed bubble Doppler is proposed and its feasibility tested in tissue-mimicking gel phantoms. pHIFU therapy uses short pulses, delivered at low pulse repetition frequency, to cause transient bubble activity that has been shown to enhance drug and gene delivery to tissues. The current gold standard for detecting and monitoring cavitation activity during pHIFU treatments is passive cavitation detection (PCD), which provides minimal information on the spatial distribution of the bubbles. B-mode imaging can detect hyperecho formation, but has very limited sensitivity, especially to small, transient microbubbles. The bubble Doppler method proposed here is based on a fusion of the adaptations of three Doppler techniques that had been previously developed for imaging of ultrasound contrast agents – color Doppler, pulse inversion Doppler, and decorrelation Doppler. Doppler ensemble pulses were interleaved with therapeutic pHIFU pulses using three different pulse sequences and standard Doppler processing was applied to the received echoes. The information yielded by each of the techniques on the distribution and characteristics of pHIFU-induced cavitation bubbles was evaluated separately, and found to be complementary. The unified approach - bubble Doppler – was then proposed to both spatially map the presence of transient bubbles and to estimate their sizes and the degree of nonlinearity. PMID:25265178

  16. Correlating intensity of pulse moment with exploration depth in surface NMR

    Science.gov (United States)

    Pan, Jianwei; Li, Zhenyu; Zhang, Yufen; Bernard, Jean; Chen, Lin; Gao, Lan; Xie, Mengying

    2017-07-01

    Because of its selective sensitivity to groundwater, surface nuclear magnetic resonance (SNMR) is a method widely applied in hydrogeology and engineering geology. However, the accurate numerical relationship between pulse moment intensity and exploration depth of this method has lacked research. Optimum pulse moment is a concept proposed to describe this correlation. By analyzing, using least-square fitting, various factors that may influence this correlation, an empirical relation for the optimum pulse moment has been obtained. The relation indicates a well-known law: to get a deeper exploration depth, a larger optimum pulse moment is needed. Moreover, from the relation, we found that the increase rate of exploration depth diminishes with the pulse moment increasing. Additionally, the correlation illustrates that the optimum exploration depth of the surface NMR method is not simply proportional to the loop diameter. Hence, to further extend the exploration depth, both the pulse moment intensity and the size of transmitter loop need to be increased simultaneously. Based on a synthetic example, we demonstrate that the optimum pulse sequence which is established from our empirical formula has a better inversion result and higher signal-to-noise ratio (SNR) when the probable depth range of the target aquifer is known.

  17. The underground electromagnetic pulse: Four representative models

    Energy Technology Data Exchange (ETDEWEB)

    Wouters, L.F.

    1989-06-01

    I describe four phenomenological models by which an underground nuclear explosion may generate electromagnetic pulses: Compton current asymmetry (or ''Compton dipole''); Uphole conductor currents (or ''casing currents''); Diamagnetic cavity plasma (or ''magnetic bubble''); and Large-scale ground motion (or ''magneto-acoustic wave''). I outline the corresponding analytic exercises and summarize the principal results of the computations. I used a 10-kt contained explosion as the fiducial case. Each analytic sequence developed an equivalent source dipole and calculated signal waveforms at representative ground-surface locations. As a comparative summary, the Compton dipole generates a peak source current moment of about 12,000 A/center dot/m in the submicrosecond time domain. The casing-current source model obtains an equivalent peak moment of about 2 /times/ 10/sup 5/ A/center dot/m in the 10- to 30-/mu/s domain. The magnetic bubble produces a magnetic dipole moment of about 7 /times/ 10/sup 6/ A/center dot/m/sup 2/, characterized by a 30-ms time structure. Finally, the magneto-acoustic wave corresponds to a magnetic dipole moment of about 600 A/center dot/m/sup 2/, with a waveform showing 0.5-s periodicities. 8 refs., 35 figs., 7 tabs.

  18. Design and application of pulse information acquisition and analysis ...

    African Journals Online (AJOL)

    Background: To design the pulse information which includes the parameter of pulse-position, pulse-number, pulse-shape and pulse-force acquisition and analysis system with function of dynamic recognition, and research the digitalization and visualization of some common cardiovascular mechanism of single pulse.

  19. Assessment of pulse rate variability by the method of pulse frequency demodulation

    Science.gov (United States)

    Hayano, Junichiro; Barros, Allan Kardec; Kamiya, Atsunori; Ohte, Nobuyuki; Yasuma, Fumihiko

    2005-01-01

    Background Due to its easy applicability, pulse wave has been proposed as a surrogate of electrocardiogram (ECG) for the analysis of heart rate variability (HRV). However, its smoother waveform precludes accurate measurement of pulse-to-pulse interval by fiducial-point algorithms. Here we report a pulse frequency demodulation (PFDM) technique as a method for extracting instantaneous pulse rate function directly from pulse wave signal and its usefulness for assessing pulse rate variability (PRV). Methods Simulated pulse wave signals with known pulse interval functions and actual pulse wave signals obtained from 30 subjects with a trans-dermal pulse wave device were analyzed by PFDM. The results were compared with heart rate and HRV assessed from simultaneously recorded ECG. Results Analysis of simulated data revealed that the PFDM faithfully demodulates source interval function with preserving the frequency characteristics of the function, even when the intervals fluctuate rapidly over a wide range and when the signals include fluctuations in pulse height and baseline. Analysis of actual data revealed that individual means of low and high frequency components of PRV showed good agreement with those of HRV (intraclass correlation coefficient, 0.997 and 0.981, respectively). Conclusion The PFDM of pulse wave signal provides a reliable assessment of PRV. Given the popularity of pulse wave equipments, PFDM may open new ways to the studies of long-term assessment of cardiovascular variability and dynamics. PMID:16259639

  20. Single attosecond pulse production with an ellipticity-modulated driving IR pulse

    Energy Technology Data Exchange (ETDEWEB)

    Strelkov, V [CELIA, Universite Bordeaux 1, 351 Cours de la liberation, 33405 Talence (France); Zair, A [CELIA, Universite Bordeaux 1, 351 Cours de la liberation, 33405 Talence (France); Tcherbakoff, O [CELIA, Universite Bordeaux 1, 351 Cours de la liberation, 33405 Talence (France); Lopez-Martens, R [Department of Physics, Lund Institute of Technology, PO Box 118, S-22100, Lund (Sweden); Cormier, E [CELIA, Universite Bordeaux 1, 351 Cours de la liberation, 33405 Talence (France); Mevel, E [CELIA, Universite Bordeaux 1, 351 Cours de la liberation, 33405 Talence (France); Constant, E [CELIA, Universite Bordeaux 1, 351 Cours de la liberation, 33405 Talence (France)

    2005-05-28

    We theoretically study attosecond pulse production via high-harmonic generation using a driving laser pulse with a time-dependent ellipticity. The theoretical approach produces results that agree with our experimental data obtained using 35 fs driving laser pulses and is further used to study the generation of single attosecond pulses with shorter laser pulses. We find an equation for the duration of the temporal window created by the time-varying driving laser polarization in which high-harmonic emission can occur. We formulate the necessary requirements concerning the driving laser field in order to confine the high-harmonic emission in the form of a single attosecond pulse. Indeed, we show that using incident 12 fs laser pulses single attosecond pulses can be produced for certain carrier-envelope phase (CEP) values of the driving pulse. For 6 fs incident laser pulses, single attosecond pulses are produced for all values of the CEP (the intensity of the attosecond pulse still depends on the actual value of the CEP). If implemented with state-of-the-art 5 fs laser pulses, this technique can even lead to the production of sub-100 as pulses. (letter to the editor)

  1. A peripheral component interconnect express-based scalable and highly integrated pulsed spectrometer for solution state dynamic nuclear polarization

    Science.gov (United States)

    He, Yugui; Feng, Jiwen; Zhang, Zhi; Wang, Chao; Wang, Dong; Chen, Fang; Liu, Maili; Liu, Chaoyang

    2015-08-01

    High sensitivity, high data rates, fast pulses, and accurate synchronization all represent challenges for modern nuclear magnetic resonance spectrometers, which make any expansion or adaptation of these devices to new techniques and experiments difficult. Here, we present a Peripheral Component Interconnect Express (PCIe)-based highly integrated distributed digital architecture pulsed spectrometer that is implemented with electron and nucleus double resonances and is scalable specifically for broad dynamic nuclear polarization (DNP) enhancement applications, including DNP-magnetic resonance spectroscopy/imaging (DNP-MRS/MRI). The distributed modularized architecture can implement more transceiver channels flexibly to meet a variety of MRS/MRI instrumentation needs. The proposed PCIe bus with high data rates can significantly improve data transmission efficiency and communication reliability and allow precise control of pulse sequences. An external high speed double data rate memory chip is used to store acquired data and pulse sequence elements, which greatly accelerates the execution of the pulse sequence, reduces the TR (time of repetition) interval, and improves the accuracy of TR in imaging sequences. Using clock phase-shift technology, we can produce digital pulses accurately with high timing resolution of 1 ns and narrow widths of 4 ns to control the microwave pulses required by pulsed DNP and ensure overall system synchronization. The proposed spectrometer is proved to be both feasible and reliable by observation of a maximum signal enhancement factor of approximately -170 for 1H, and a high quality water image was successfully obtained by DNP-enhanced spin-echo 1H MRI at 0.35 T.

  2. Analysis of folded pulse forming line operation

    Science.gov (United States)

    Domonkos, M. T.; Watrous, J.; Parker, J. V.; Cavazos, T.; Slenes, K.; Heidger, S.; Brown, D.; Wilson, D.

    2014-09-01

    A compact pulse forming line (CPFL) concept based on a folded transmission line and high-breakdown strength dielectric was explored through an effort combining proof-of-principle experiments with electromagnetic modeling. A small-scale folded CPFL was fabricated using surface-mount ceramic multilayer capacitors. The line consisted of 150 capacitors close-packed in parallel and delivered a 300 ns flat-top pulse. The concept was carried to a 10 kV class device using a polymer-ceramic nanocomposite dielectric with a permittivity of 37.6. The line was designed for a 161 ns FWHM length pulse into a matched load. The line delivered a 110 ns FWHM pulse, and the pulse peak amplitude exceeded the matched load ideal. Transient electromagnetic analysis using the particle-in-cell code ICEPIC was conducted to examine the nature of the unexpected pulse shortening and distortion. Two-dimensional analysis failed to capture the anomalous behavior. Three-dimensional analysis replicated the pulse shape and revealed that the bends were largely responsible for the pulse shortening. The bends not only create the expected reflection of the incident TEM wave but also produce a non-zero component of the Poynting vector perpendicular to the propagation direction of the dominant electromagnetic wave, resulting in power flow largely external to the PFL. This analysis explains both the pulse shortening and the amplitude of the pulse.

  3. Hybrid Pulsed Nd:YAG Laser

    Science.gov (United States)

    Miller, Sawyer; Trujillo, Skyler; Fort Lewis College Laser Group Team

    This work concerns the novel design of an inexpensive pulsed Nd:YAG laser, consisting of a hybrid Kerr Mode Lock (KLM) and Q-switch pulse. The two pulse generation systems work independently, non simultaneously of each other, thus generating the ability for the user to easily switch between ultra-short pulse widths or large energy density pulses. Traditionally, SF57 glass has been used as the Kerr medium. In this work, novel Kerr mode-locking mediums are being investigated including: tellurite compound glass (TeO2), carbon disulfide (CS2), and chalcogenide glass. These materials have a nonlinear index of refraction orders of magnitude,(n2), larger than SF57 glass. The Q-switched pulse will utilize a Pockels cell. As the two pulse generation systems cannot be operated simultaneously, the Pockels cell and Kerr medium are attached to kinematic mounts, allowing for quick interchange between systems. Pulse widths and repetition rates will vary between the two systems. A goal of 100 picosecond pulse widths are desired for the mode-locked system. A goal of 10 nanosecond pulse widths are desired for the Q-switch system, with a desired repetition rate of 50 Hz. As designed, the laser will be useful in imaging applications.

  4. Kinetics of high pressure argon-helium pulsed gas discharge

    Science.gov (United States)

    Emmons, D. J.; Weeks, D. E.

    2017-05-01

    Simulations of a pulsed direct current discharge are performed for a 7% argon in helium mixture at a pressure of 270 Torr using both zero- and one-dimensional models. Kinetics of species relevant to the operation of an optically pumped rare-gas laser are analyzed throughout the pulse duration to identify key reaction pathways. Time dependent densities, electron temperatures, current densities, and reduced electric fields in the positive column are analyzed over a single 20 μs pulse, showing temporal agreement between the two models. Through the use of a robust reaction rate package, radiation trapping is determined to play a key role in reducing A r (1 s5) metastable loss rates through the reaction sequence A r (1 s5)+e-→A r (1 s4)+e- followed by A r (1 s4)→A r +ℏω . Collisions with He are observed to be responsible for A r (2 p9) mixing, with nearly equal rates to A r (2 p10) and A r (2 p8) . Additionally, dissociative recombination of A r2+ is determined to be the dominant electron loss mechanism for the simulated discharge conditions and cavity size.

  5. Pulse-Flow Microencapsulation System

    Science.gov (United States)

    Morrison, Dennis R.

    2006-01-01

    The pulse-flow microencapsulation system (PFMS) is an automated system that continuously produces a stream of liquid-filled microcapsules for delivery of therapeutic agents to target tissues. Prior microencapsulation systems have relied on batch processes that involve transfer of batches between different apparatuses for different stages of production followed by sampling for acquisition of quality-control data, including measurements of size. In contrast, the PFMS is a single, microprocessor-controlled system that performs all processing steps, including acquisition of quality-control data. The quality-control data can be used as real-time feedback to ensure the production of large quantities of uniform microcapsules.

  6. Pulsed Terahertz Spectroscopy of Biomolecules

    Science.gov (United States)

    Markelz, A. G.; Heilweil, E. J.

    1998-03-01

    Measurements of the collective vibrational modes associated with the 3D tertiary structure of biomolecules were undertaken using pulse terahertz spectroscopy. Transmission measurements of calf thymus DNA (CT-DNA), bovine serum albumin (BSA), and collagen were made for 2 cm-1 to 45 cm-1. For all three biomolecules, low frequency absorption bands could be distinguished from a broadband absorption increasing with frequency. For lyophilized powder samples, features appear at 15 cm-1 and 22 cm-1 for CT-DNA, 10 cm-1 for BSA, and 8 cm-1 and 12 cm-1 for collagen. Measurements were performed as a function of hydration and conformation.

  7. Double sequence core theorems

    Directory of Open Access Journals (Sweden)

    Richard F. Patterson

    1999-01-01

    Full Text Available In 1900, Pringsheim gave a definition of the convergence of double sequences. In this paper, that notion is extended by presenting definitions for the limit inferior and limit superior of double sequences. Also the core of a double sequence is defined. By using these definitions and the notion of regularity for 4-dimensional matrices, extensions, and variations of the Knopp Core theorem are proved.

  8. Efficient probability sequence

    OpenAIRE

    Regnier, Eva

    2014-01-01

    A probability sequence is an ordered set of probability forecasts for the same event. Although single-period probabilistic forecasts and methods for evaluating them have been extensively analyzed, we are not aware of any prior work on evaluating probability sequences. This paper proposes an efficiency condition for probability sequences and shows properties of efficient forecasting systems, including memorylessness and increasing discrimination. These results suggest tests for efficiency and ...

  9. Efficient probability sequences

    OpenAIRE

    Regnier, Eva

    2014-01-01

    DRMI working paper A probability sequence is an ordered set of probability forecasts for the same event. Although single-period probabilistic forecasts and methods for evaluating them have been extensively analyzed, we are not aware of any prior work on evaluating probability sequences. This paper proposes an efficiency condition for probability sequences and shows properties of efficiency forecasting systems, including memorylessness and increasing discrimination. These res...

  10. Scan parameters and the diffusion emphasis effect in diffusion-weighted imaging using a motion-probing gradient preparation pulse.

    Science.gov (United States)

    Takahashi, Daisuke; Tanji, Hajime; Yamaki, Tomoya; Obara, Makoto; Machida, Yoshio

    2014-07-01

    Diffusion-sensitized driven equilibrium preparation (DSDE) is a gradient echo (GRE) diffusion-weighted imaging (DWI) sequence that employs a motion-probing gradient (MPG) preparation pulse and phase cycling. In DSDE, several scan parameters of the MPG preparation pulse and the GRE sequence affect diffusion sensitivity. Our investigation of the relationship between these scan parameters and the diffusion emphasis effect revealed the importance of "prep.TE" in the MPG preparation pulse and "TFE shot interval" in the gradient echo sequence. Appropriate choice of these parameters allows DSDE to provide a similar DWI to that of conventional single-shot SEEPI DWI. We therefore concluded DSDE to be a useful DWI method.

  11. Development of a pulse programmer for magnetic resonance imaging using a personal computer and a high-speed digital input–output board

    OpenAIRE

    Hashimoto, Seitaro; Kose, Katsumi; Haishi, Tomoyuki

    2012-01-01

    We have developed a pulse programmer for magnetic resonance imaging (MRI) using a personal computer and a commercially available high-speed digital input–output board. The software for the pulse programmer was developed using C/C++ and .NET Framework 2.0 running under the Windows 7 operating system. The pulse programmer was connected to a digital MRI transceiver using a 32-bit parallel interface, and 128-bit data (16 bits × 8 words) for the pulse sequence and the digitally detected MRI signal...

  12. Investigation of the effect of a variety of pulse errors on spin I=1 quadrupolar alignment echo spectroscopy.

    Science.gov (United States)

    Ma, Xiang; Sun, Cheng; Boutis, Gregory S

    2011-08-01

    We report on an analysis of a well known three-pulse sequence for generating and detecting spin I=1 quadrupolar order when various pulse errors are taken into account. In the situation of a single quadrupolar frequency, such as the case found in a single crystal, we studied the potential leakage of single and/or double quantum coherence when a pulse flip error, finite pulse width effect, RF transient or a resonance offset is present. Our analysis demonstrates that the four-step phase cycling scheme studied is robust in suppressing unwanted double and single quantum coherence as well as Zeeman order that arise from the experimental artifacts, allowing for an unbiased measurement of the quadrupolar alignment relaxation time, T(1Q). This work also reports on distortions in quadrupolar alignment echo spectra in the presence of experimental artifacts in the situation of a powdered sample, by simulation. Using our simulation tool, it is demonstrated that the spectral distortions associated with the pulse artifacts may be minimized, to some extent, by optimally choosing the time between the first two pulses. We highlight experimental results acquired on perdeuterated hexamethylbenzene and polyethylene that demonstrate the efficacy of the phase cycling scheme for suppressing unwanted quantum coherence when measuring T(1Q). It is suggested that one employ two separate pulse sequences when measuring T(1Q) to properly analyze the short time behavior of quadrupolar alignment relaxation data. Copyright © 2011 Elsevier Inc. All rights reserved.

  13. Conditions for effects of radiation pulsing

    CERN Document Server

    Trinkaus, H

    2002-01-01

    The possibility of pulsing effects on radiation damage is due to differences in the delay times of relevant defect reactions and/or to the non-linear dependence of such reactions on defect production rates. Thus, significant pulsing effects require (1) proper relationships of the internal time scales of defect production and reaction to the time scales of pulsing and (2) sufficiently large pulsing induced fluctuations in relevant microstructural variables. We show that the first condition, which we quantify by a 'relative dynamic bias', is indeed fulfilled in wide ranges of the main irradiation parameters. The second condition, quantified by an 'absolute dynamic bias', is, however, found to restrict the parameter ranges of possible pulsing effects substantially. For planned spallation neutron sources and similar accelerator driven systems facilities we find, for instance, that, in the temperature range of interest, the defect yield of one pulse (controlling the absolute dynamic bias) is much too small to allo...

  14. VCSEL based, wearable, continuously monitoring pulse oximeter.

    Science.gov (United States)

    Kollmann, Daniel; Hogan, William K; Steidl, Charles; Hibbs-Brenner, Mary K; Hedin, Daniel S; Lichter, Patrick A

    2013-01-01

    We present the development of a novel pulse oximeter based on low power, low cost, Vertical Cavity Surface Emitting Laser (VCSEL) technology. This new design will help address a need to perform regular measurements of pulse oximetry for patients with chronic obstructive pulmonary disease. VCSELs with wavelengths suitable for pulse oximetry were developed and packaged in a PLCC package for a low cost solution that is easy to integrate into a pulse oximeter design. The VCSELs were integrated into a prototype pulse oximeter that is unobtrusive and suitable for long term wearable use. The prototype achieved good performance compared the Nonin Onyx II pulse oximeter at less than one fifth the weight in a design that can be worn behind the ear like a hearing aid.

  15. Multi-pulse scheme for laser-guided electrical breakdown of air

    Science.gov (United States)

    Polynkin, Pavel

    2017-10-01

    Channeling an extended electrical breakdown of air by a laser beam is a long-standing challenge in applied laser science. Virtually all previously reported experiments on discharge channeling by femtosecond laser beams relied on the application of a single laser pulse and have been conducted with discharge gaps of less than one meter, in which case the direct ohmic heating of the laser-generated plasma by the applied DC electric field is the dominant channeling mechanism. We report a laboratory-scale demonstration of a channeling approach that makes use of concatenated plasma filaments produced by a sequence of multiple ultrashort laser pulses. Direct ohmic heating of the guiding channel is eliminated through the introduction of large temporal delays between the individual laser pulses in the pulse sequence. We propose an extension of this scheme to channeling kilometer-scale discharges, including natural lightning. Our proposed approach alleviates the fundamental range limitations inherent to the single-pulse schemes reported previously. It can channel discharges propagating in either direction and along curved paths.

  16. An ultra-low cost NMR device with arbitrary pulse programming

    Science.gov (United States)

    Chen, Hsueh-Ying; Kim, Yaewon; Nath, Pulak; Hilty, Christian

    2015-06-01

    Ultra-low cost, general purpose electronics boards featuring microprocessors or field programmable gate arrays (FPGA) are reaching capabilities sufficient for direct implementation of NMR spectrometers. We demonstrate a spectrometer based on such a board, implemented with a minimal need for the addition of custom electronics and external components. This feature allows such a spectrometer to be readily implemented using typical knowledge present in an NMR laboratory. With FPGA technology, digital tasks are performed with precise timing, without the limitation of predetermined hardware function. In this case, the FPGA is used for programming of arbitrarily timed pulse sequence events, and to digitally generate required frequencies. Data acquired from a 0.53 T permanent magnet serves as a demonstration of the flexibility of pulse programming for diverse experiments. Pulse sequences applied include a spin-lattice relaxation measurement using a pulse train with small-flip angle pulses, and a Carr-Purcell-Meiboom-Gill experiment with phase cycle. Mixing of NMR signals with a digitally generated, 4-step phase-cycled reference frequency is further implemented to achieve sequential quadrature detection. The flexibility in hardware implementation permits tailoring this type of spectrometer for applications such as relaxometry, polarimetry, diffusometry or NMR based magnetometry.

  17. Cryogenic pulsed inductive microwave magnetometer

    Science.gov (United States)

    Kos, A. B.; Nibarger, J. P.; Lopusnik, R.; Silva, T. J.; Celinski, Z.

    2003-05-01

    A cryogenic pulsed inductive microwave magnetometer is used to characterize the switching dynamics in thin-film magnetic materials at low temperatures and microwave frequencies. The system is contained inside a 20-cm-diam ultrahigh vacuum chamber and cooled by a cryopump that allows measurements between 20 and 350 K. A temperature controller regulates the sample temperature using two silicon diodes as sensors. Applied magnetic fields of up to 36 kA/m (450 Oe) are generated by a four-pole, water-cooled electromagnet with independent control of each axis. Magnetic switching in the sample is driven by high-speed current step pulses in a coplanar waveguide structure with the sample placed in a flip-chip configuration. A 20 GHz sampling oscilloscope is used to record the dynamics of the magnetic reorientation. The switching dynamics are given for a 10-nm-thick Ni-Fe film at 30 K in response to a 1 kA/m field step.

  18. Pulsed Power Bibliography. Volume 2. Annotated Bibliography.

    Science.gov (United States)

    1983-08-01

    inoestigated at different pressures and generating signal nacimum peak pouer; One flow rote and sturate volume detereine amplitudes. 22 Refs. mauimumrunn...and Local Thermodyvasic Equilibrium INTERUPTION (LTE) of the arc planna. .srical solutions for the field variables T.E. Browne Jr. are obtained by...complete high current pulse amplifier were fabricated and teste forSwpplTss. Pulse Ognerater; S inductsr DiOedes; diode sturation charsctettcs and pulse

  19. New pulse modulator with low switching frequency

    Directory of Open Access Journals (Sweden)

    Golub V. S.

    2014-12-01

    Full Text Available The author presents an integrating pulse modulator (analog signal converter with the pulse frequency and duration modulation similar to sigma-delta modulation (with low switching frequency, without quantization. The modulator is characterized by the absence of the quantization noise inherent in sigma-delta modulator, and a low switching frequency, unlike the pulse-frequency modulator. The modulator is recommended, in particular, to convert signals at the input of the class D power amplifier.

  20. Femtosecond Laser Pulses Principles and Experiments

    CERN Document Server

    Rullière, Claude

    2005-01-01

    This smooth introduction for advanced undergraduates starts with the fundamentals of lasers and pulsed optics. Thus prepared, the student is introduced to short and ultrashort laser pulses, and learns how to generate, manipulate, and measure them. Spectroscopic implications are also discussed. The second edition has been completely revised and includes two new chapters on some of the most promising and fast-developing applications in ultrafast phenomena: coherent control and attosecond pulses.

  1. Pulsed-Power Burnout of Integrated Circuits

    Science.gov (United States)

    Results of pulsed-power burnout testing the Fairchild 9046 quad dual-input nand gate and the Amelco 6041 three-input nand gate showed the circuits to...be vulnerable to junction burnout for pulses of less than 100 V and pulse widths on the order of 100 nsec. Calculations based on Wunsch-Bell junction... burnout theory showed good agreement with the experimental results. Sample calculations applying Wunsch-Bell theory to integrated circuits are given.

  2. Dark pulse quantum dot diode laser.

    Science.gov (United States)

    Feng, Mingming; Silverman, Kevin L; Mirin, Richard P; Cundiff, Steven T

    2010-06-21

    We describe an operating regime for passively mode-locked quantum dot diode laser where the output consists of a train of dark pulses, i.e., intensity dips on a continuous background. We show that a dark pulse train is a solution to the master equation for mode-locked lasers. Using simulations, we study stability of the dark pulses and show they are consistent with the experimental results.

  3. Radiation spectroscopy by digital pulse height analysis

    Energy Technology Data Exchange (ETDEWEB)

    Los Arcos, J.M. (Metrologia de Radiaciones, Instituto de Investigacion Basica, CIEMAT, Avda. Complutense 22, Madrid 28040 (Spain)); Garcia-Torano, E. (Metrologia de Radiaciones, Instituto de Investigacion Basica, CIEMAT, Avda. Complutense 22, Madrid 28040 (Spain)); Olmos, P. (Tecnologias Avanzadas de Sensores, Direccion de Tecnologia, CIEMAT, Avda. Complutense 22, Madrid 28040 (Spain)); Marin, J. (Tecnologias Avanzadas de Sensores, Direccion de Tecnologia, CIEMAT, Avda. Complutense 22, Madrid 28040 (Spain))

    1994-12-30

    This paper presents a new version of the Digital Pulse-Height Analysis (DPHA) method described in a previous paper, which is based on data acquisition through a personal computer using a flash-ADC card followed by numerical processing of pulses in the same computer. Performance tests carried out with a pulse generator and gamma-ray spectra have been carried out and their results are discussed. ((orig.))

  4. Pulsed writing of solid state holograms.

    Science.gov (United States)

    Gaylord, T. K.; Rabson, T. A.; Tittel, F. K.; Quick, C. R.

    1973-01-01

    The pulsed writing of volume holograms in lithium niobate is reported, both with 200-nsec and 20-nsec duration pulses. This information is of particular interest in high capacity information storage applications since it indicates that writing times at least as short as 20-nsec are readily possible. A series of pulses was used in each case, and the diffraction efficiency was monitored using a He-Ne laser operating at 6328 A and aligned to its corresponding Bragg angle.

  5. PULSE DRYING EXPERIMENT AND BURNER CONSTRUCTION

    Energy Technology Data Exchange (ETDEWEB)

    Robert States

    2006-07-15

    Non steady impingement heat transfer is measured. Impingement heating consumes 130 T-BTU/Yr in paper drying, but is only 25% thermally efficient. Pulse impingement is experimentally shown to enhance heat transfer by 2.8, and may deliver thermal efficiencies near 85%. Experimental results uncovered heat transfer deviations from steady theory and from previous investigators, indicating the need for further study and a better theoretical framework. The pulse burner is described, and its roll in pulse impingement is analyzed.

  6. Chromosome number9 specific repetitive DNA sequence

    Energy Technology Data Exchange (ETDEWEB)

    Joste, N.E.; Cram, L.S.; Hildebrand, C.E.; Jones, M.; Longmire, J.; Robinson, T.; Moyzis, R.K.

    1986-05-01

    Human repetitive DNA libraries have been constructed and various recombinant DNA clones isolated that are likely candidates for chromosome specific sequences. The first clone tested (pHuR 98; plasmid human repeat 98) was biotinylated and hybridized to human chromosomes in situ. The hybridized recombinant probe was detected with fluoresceinated avidin, and chromosomes were counter-stained with either propidium iodide or distamycin-DAPI. Specific hybridization to chromosome band 9q1 was obtained. The localization was confirmed by hybridizing radiolabeled pHuR 98 DNA to human chromosomes sorted by flow cytometry. Various methods, including orthogonal field pulsed gel electrophoresis analysis indicate that 75 kilobase blocks of this sequence are interspersed with other repetitive DNA sequences in this chromosome band. This study is the first to report a human repetitive DNA sequence uniquely localized to a specific chromosome. This clone provides an easily detected and highly specific chromosomal marker for molecular cytogenetic analyses in numerous basic research and clinical studies.

  7. Pulsed Single Frequency MOPA Laser Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Latest advances in semiconductor optoelectronics makes it possible to develop compact light weight robust sources of coherent optical pulses, demanded for numerous...

  8. Pulse reversal plating of nickel alloys

    DEFF Research Database (Denmark)

    Tang, Peter Torben

    2007-01-01

    Pulse plating has previously been reported to improve the properties of nickel and nickel alloy deposits. Typically, focus has been on properties such as grain size, hardness and smoothness. When pulse plating is to be utilised for microtechnologies such as microelectromechanical systems (MEMS......), internal stress and material distribution are even more important. With baths based upon nickel chloride, and nickel and cobalt chlorides, pulse reversal plating of both pure nickel and nickel-cobalt alloys has been used to fabricate tools for microinjection moulding. Pulse reversal plating of ternary soft...

  9. MEDEA II two-pulse generator development

    Energy Technology Data Exchange (ETDEWEB)

    Bieniosek, F.M.; Honig, J.; Theby, E.A. (McDonnell Douglas Research Laboratories, P. O. Box 516, St. Louis, Missouri 63166 (USA))

    1990-06-01

    This article discusses improvements in the efficiency, output power, and operational flexibility of MEDEA II, a double-pulse electron beam accelerator at McDonnell Douglas Research Laboratories. A modified charging circuit, based on the triple-resonance pulse transformer concept, was implemented on both of MEDEA II's two stages. The output switches were modified to increase maximum output voltages, and a new, second output switch with asymmetric breakdown characteristics was developed. To avoid degradation of the second-pulse output waveform at the diode, a keep-alive circuit was installed. The effects of diode closure on double-pulse operation are also discussed.

  10. MEDEA II two-pulse generator development

    Science.gov (United States)

    Bieniosek, F. M.; Honig, J.; Theby, E. A.

    1990-06-01

    This article discusses improvements in the efficiency, output power, and operational flexibility of MEDEA II, a double-pulse electron beam accelerator at McDonnell Douglas Research Laboratories. A modified charging circuit, based on the triple-resonance pulse transformer concept, was implemented on both of MEDEA II's two stages. The output switches were modified to increase maximum output voltages, and a new, second output switch with asymmetric breakdown characteristics was developed. To avoid degradation of the second-pulse output waveform at the diode, a keep-alive circuit was installed. The effects of diode closure on double-pulse operation are also discussed.

  11. Pulsed Laser Spectroscopy: An Inexpensive Approach

    Science.gov (United States)

    Daly, J. G.; Hastings, R.; Schmidt, J. A.

    1982-10-01

    The assembly of a pulsed laser spectroscopy laboratory is presented. The authors describe how they constructed pulsed lasers, fast photodetectors, a boxcar signal averager, and associated equipment. A molecular nitrogen laser operating up to 50 Hz with an ultraviolet (337.1 nm) 700 kW pulse was used to optically pump an organic dye laser. The resulting output could be tuned from 360.0 to 680.0 nm. This pulse was typically 30 kW and 8 nsec, which makes it ideally suited to selective excitation and fluorescence studies. By constructing this equipment, it is estimated that the investment was one-tenth the cost of commercial components.

  12. Ultrashort Laser Pulses in Biology and Medicine

    CERN Document Server

    Braun, Markus; Zinth, Wolfgang

    2008-01-01

    Sources of ultrashort laser pulses are nowadays commercially available and have entered many areas of research and development. This book gives an overview of biological and medical applications of these laser pulses. The briefness of these laser pulses permits the tracing of the fastest processes in photo-active bio-systems, which is one focus of the book. The other focus is applications that rely on the high peak intensity of ultrashort laser pulses. Examples covered span non-linear imaging techniques, optical tomography, and laser surgery.

  13. Synthesis of Nanosecond Ultrawideband Radiation Pulses

    Science.gov (United States)

    Koshelev, V. I.; Plisko, V. V.; Sevostyanov, E. A.

    2017-12-01

    The synthesis of electromagnetic pulses with an extended spectrum by summing pulses of different duration in free space has been studied. The radiation spectrum has been estimated analytically for a 4-element array of combined antennas excited by bipolar voltage pulses of duration 0.5, 1, 2, and 3 ns. It has been shown experimentally that radiation with a spectral width of more than three octaves can be produced using a 2×2 array of combined antennas excited by bipolar pulses of duration 2 and 3 ns.

  14. A Chaotic Pulse-Time Modulation Method for Digital Communication

    OpenAIRE

    Nguyen Xuan Quyen; Vu Van Yem; Thang Manh Hoang

    2012-01-01

    We present and investigate a method of chaotic pulse-time modulation (PTM) named chaotic pulse-width-position modulation (CPWPM) which is the combination of pulse-position-modulation (PPM) and pulse-width modulation (PWM) with the inclusion of chaos technique for digital communications. CPWPM signal is in the pulse train format, in which binary information is modulated onto chaotically-varied intervals of position and width of pulses, and therefore two bits are encoded on a single pulse. The ...

  15. Pierre Robin sequence

    Science.gov (United States)

    Pierre Robin sequence (or syndrome) is a condition in which an infant has a smaller than normal lower jaw, a tongue ... The exact causes of Pierre Robin sequence are unknown. It may be ... jaw develops slowly before birth, but may grow faster during ...

  16. Cosmetology: Scope and Sequence.

    Science.gov (United States)

    Nashville - Davidson County Metropolitan Public Schools, TN.

    This scope and sequence guide, developed for a cosmetology vocational education program, represents an initial step in the development of a systemwide articulated curriculum sequence for all vocational programs within the Metropolitan Nashville Public School System. It was developed as a result of needs expressed by teachers, parents, and the…

  17. sequences in Chickpea

    African Journals Online (AJOL)

    Milena

    Author(s) retain the copyright of this article http://www.academicjournals.org/AJB. African Journal of Biotechnology. Full Length Research Paper. Evaluation of genetic divergence and phylogenetic relationship using sequence-tagged microsatellite. (STMS) sequences in Chickpea (Cicer arietinum L.) genotypes. Himanshu ...

  18. Sequences, Series, and Mathematica.

    Science.gov (United States)

    Mathews, John H.

    1992-01-01

    Describes how the computer algebra system Mathematica can be used to enhance the teaching of the topics of sequences and series. Examines its capabilities to find exact, approximate, and graphically generated approximate solutions to problems from these topics and to understand proofs about sequences. (MDH)

  19. Group velocity and pulse lengthening of mismatched laser pulses in plasma channels

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, Carl; Benedetti, Carlo; Esarey, Eric; van Tilborg, Jeroen; Leemans, Wim

    2011-07-07

    Analytic solutions are presented to the non-paraxial wave equation describing an ultra-short, low-power, laser pulse propagating in aplasma channel. Expressions for the laser pulse centroid motion and laser group velocity are derived, valid for matched and mismatchedpropagation in a parabolic plasma channel, as well as in vacuum, for an arbitrary Laguerre-Gaussian laser mode. The group velocity of amismatched laser pulse, for which the laser spot size is strongly oscillating, is found to be independent of propagation distance andsignificantly less than that of a matched pulse. Laser pulse lengthening of a mismatched pulse owing to laser mode slippage isexamined and found to dominate over that due to dispersive pulse spreading for sufficiently long pulses. Analytic results are shown tobe in excellent agreement with numerical solutions of the full Maxwell equations coupled to the plasma response. Implications for plasmachannel diagnostics are discussed.

  20. Nanotechnology and Nanopore Sequencing.

    Science.gov (United States)

    Abedini-Nassab, Roozbeh

    2017-01-01

    DNA sequencing is one of the crucially important tasks in the fields of genetics and cellular biology, which is benefiting from nanotechnology. DNA carries genetic information and sequencing it in a quick way helps researchers in achieving essential goals, including personalized medicine. Solid state nanopores potentially can offer more durability, in sequencing biomolecules, over the proteinbased nanopores. In recent years, various ideas are introduced towards the goal of fast and low cost sequencing. In this review article recent advances presented in journal articles as well as patents in this field, including sequencing methods, membrane materials and their fabrication techniques, drilling methods, and biomolecule translocation speed control ideas are investigated. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  1. Estimation of aortic compliance using magnetic resonance pulse wave velocity measurement

    Energy Technology Data Exchange (ETDEWEB)

    Boese, J.M.; Bock, M.; Schoenberg, S.O.; Schad, L.R. [Deutsches Krebsforschungszentrum, Radiologische Diagnostik und Therapie, D-69120 Heidelberg (Germany)

    2000-06-01

    A method for compliance estimation employing magnetic resonance pulse wave velocity measurement is presented. Time-resolved flow waves are recorded at several positions along the vessel using a phase contrast sequence, and pulse wave velocity is calculated from the delay of the wave onsets. Using retrospective cardiac gating in combination with an optically decoupled electrocardiogram acquisition, a high temporal resolution of 3 ms can be achieved. A phantom set-up for the simulation of pulsatile flow in a compliant vessel is described. In the phantom, relative errors of pulse wave velocity estimation were found to be about 15%, whereas in a volunteer, larger errors were found that might be caused by vessel branches. Results of pulse wave velocity estimation agree with directaortic distension measurements which rely on a peripheral estimate of aortic pressure and are therefore less accurate. Studies in 12 volunteers show values of pulse wave velocity consistent with the literature; in particular the well-known increase in pulse wave velocity with age was observed. Preliminary results show that the method can be applied to aortic aneurysms. (author)

  2. Functional polyethylene glycol derivatives nanostructured thin films synthesized by matrix-assisted pulsed laser evaporation

    Energy Technology Data Exchange (ETDEWEB)

    Cristescu, R., E-mail: rodica.cristescu@inflpr.ro [National Institute for Lasers, Plasma and Radiation Physics, Lasers Department, Bucharest-Magurele (Romania); Popescu, C.; Popescu, A.; Grigorescu, S.; Mihailescu, I.N. [National Institute for Lasers, Plasma and Radiation Physics, Lasers Department, Bucharest-Magurele (Romania); Mihaiescu, D. [University of Agriculture Sciences and Veterinary Medicine, 59 Marasti, Bucharest (Romania); Gittard, S.D.; Narayan, R.J. [Biomedical Engineering, University of North Carolina, Chapel Hill, NC (United States); Buruiana, T. [Petru Poni Institute of Macromolecular Chemistry, Aleea Grigore Ghica Voda, 41A, Iasi (Romania); Stamatin, I. [University of Bucharest, 3Nano-SAE Research Center, PO Box MG-38, Bucharest-Magurele (Romania); Chrisey, D.B. [Rensselaer Polytechnic Institute, Department of Materials Science and Engineering, Troy, NY (United States)

    2009-09-30

    We report the thin film deposition by matrix-assisted pulsed laser evaporation (MAPLE) of a polymer conjugate with an hydrophilic sequence between metronidazole molecules that was covalently attached to both oligomer ends of carboxylate poly(ethylene glycol) (PEG 1.5-metronidazole). A pulsed KrF* excimer laser was used to deposit the drug-polymer composite films. Fourier transform infrared spectroscopy was used to demonstrate that MAPLE-transferred materials exhibited chemical properties similar to the starting materials. The dependence of the surface morphology on incident laser fluence is given.

  3. Pulse Splitting for Harmonic Beamforming in Time-Modulated Linear Arrays

    Directory of Open Access Journals (Sweden)

    Lorenzo Poli

    2014-01-01

    Full Text Available A novel strategy for harmonic beamforming in time-modulated linear arrays is proposed. The pulse splitting technique is exploited to simultaneously generate two harmonic patterns, one at the central frequency and another at a preselected harmonic of arbitrary order, while controlling the maximum level of the remaining sideband radiations. An optimization strategy based on the particle swarm optimizer is developed in order to determine the optimal parameters describing the pulse sequence used to modulate the excitation weights of the array elements. Representative numerical results are reported and discussed to point out potentialities and limitations of the proposed approach.

  4. Laser-induced retinal damage threshold for repetitive-pulse exposure to 100-microsecs pulses

    Science.gov (United States)

    2014-10-07

    and 1000 Hz (Fig. 3). In Fig. 4, PS model predictions based on the experimentally determined single pulse ED50 and probit slope are compared to the...pulse repetition frequencies. The variation of the ED50 with the number of pulses is described well by the probability summation model , in which each...summation (PS) model of Menendez et al.15–17 For this injury mechanism, the cumulative threshold is depen dent only on the number of pulses in the exposure

  5. Efficient chirped-pulse amplification of sub-20 fs laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Matsuoka, Shinichi; Yamakawa, Koichi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-03-01

    We have developed a model for ultrabroadband and ultrashort pulse amplification including the effects of a pulse shaper for regenerative pulse shaping, gain narrowing and gain saturation in the amplifiers. Thin solid etalons are used to control both gain narrowing and gain saturation during amplification. This model has been used to design an optimized Ti:sapphire amplifier system for producing efficiently pulses of < 20-fs duration with approaching peak and average powers of 100 TW and 20 W. (author)

  6. Fiber Optical Parametric Chirped Pulse Amplification of Sub-Picosecond Pulses

    DEFF Research Database (Denmark)

    Cristofori, Valentina; Lali-Dastjerdi, Zohreh; Da Ros, Francesco

    2013-01-01

    We demonstrate experimentally, for the first time to our knowledge, fiber optical parametric chirped pulse amplification of 400-fs pulses. The 400-fs signal is stretched, amplified by 26 dB and compressed back to 500 fs.......We demonstrate experimentally, for the first time to our knowledge, fiber optical parametric chirped pulse amplification of 400-fs pulses. The 400-fs signal is stretched, amplified by 26 dB and compressed back to 500 fs....

  7. Efficient reflection grisms for pulse compression and dispersion compensation of femtosecond pulses.

    Science.gov (United States)

    Gibson, Emily A; Gaudiosi, David M; Kapteyn, Henry C; Jimenez, Ralph; Kane, Steve; Huff, Rachel; Durfee, Charles; Squier, Jeff

    2006-11-15

    Efficient reflection grisms for pulse-compression and material-dispersion compensation have been designed and demonstrated in a 40 fs, 300 microJ, 5 kHz downchirped pulse amplification system for the first time to our knowledge. A grism design for 800 nm femtosecond laser pulse dispersion compensation applications is realized by using standard, commercial diffraction gratings.

  8. Pulse consumption, satiety, and weight management.

    Science.gov (United States)

    McCrory, Megan A; Hamaker, Bruce R; Lovejoy, Jennifer C; Eichelsdoerfer, Petra E

    2010-11-01

    The prevalence of obesity has reached epidemic proportions, making finding effective solutions to reduce obesity a public health priority. One part of the solution could be for individuals to increase consumption of nonoilseed pulses (dry beans, peas, chickpeas, and lentils), because they have nutritional attributes thought to benefit weight control, including slowly digestible carbohydrates, high fiber and protein contents, and moderate energy density. Observational studies consistently show an inverse relationship between pulse consumption and BMI or risk for obesity, but many do not control for potentially confounding dietary and other lifestyle factors. Short-term (≤1 d) experimental studies using meals controlled for energy, but not those controlled for available carbohydrate, show that pulse consumption increases satiety over 2-4 h, suggesting that at least part of the effect of pulses on satiety is mediated by available carbohydrate amount or composition. Randomized controlled trials generally support a beneficial effect of pulses on weight loss when pulse consumption is coupled with energy restriction, but not without energy restriction. However, few randomized trials have been conducted and most were short term (3-8 wk for whole pulses and 4-12 wk for pulse extracts). Overall, there is some indication of a beneficial effect of pulses on short-term satiety and weight loss during intentional energy restriction, but more studies are needed in this area, particularly those that are longer term (≥1 y), investigate the optimal amount of pulses to consume for weight control, and include behavioral elements to help overcome barriers to pulse consumption.

  9. Pulse Consumption, Satiety, and Weight Management1

    Science.gov (United States)

    McCrory, Megan A.; Hamaker, Bruce R.; Lovejoy, Jennifer C.; Eichelsdoerfer, Petra E.

    2010-01-01

    The prevalence of obesity has reached epidemic proportions, making finding effective solutions to reduce obesity a public health priority. One part of the solution could be for individuals to increase consumption of nonoilseed pulses (dry beans, peas, chickpeas, and lentils), because they have nutritional attributes thought to benefit weight control, including slowly digestible carbohydrates, high fiber and protein contents, and moderate energy density. Observational studies consistently show an inverse relationship between pulse consumption and BMI or risk for obesity, but many do not control for potentially confounding dietary and other lifestyle factors. Short-term (≤1 d) experimental studies using meals controlled for energy, but not those controlled for available carbohydrate, show that pulse consumption increases satiety over 2–4 h, suggesting that at least part of the effect of pulses on satiety is mediated by available carbohydrate amount or composition. Randomized controlled trials generally support a beneficial effect of pulses on weight loss when pulse consumption is coupled with energy restriction, but not without energy restriction. However, few randomized trials have been conducted and most were short term (3–8 wk for whole pulses and 4–12 wk for pulse extracts). Overall, there is some indication of a beneficial effect of pulses on short-term satiety and weight loss during intentional energy restriction, but more studies are needed in this area, particularly those that are longer term (≥1 y), investigate the optimal amount of pulses to consume for weight control, and include behavioral elements to help overcome barriers to pulse consumption. PMID:22043448

  10. Standardization of Rocket Engine Pulse Time Parameters

    Science.gov (United States)

    Larin, Max E.; Lumpkin, Forrest E.; Rauer, Scott J.

    2001-01-01

    Plumes of bipropellant thrusters are a source of contamination. Small bipropellant thrusters are often used for spacecraft attitude control and orbit correction. Such thrusters typically operate in a pulse mode, at various pulse lengths. Quantifying their contamination effects onto spacecraft external surfaces is especially important for long-term complex-geometry vehicles, e.g. International Space Station. Plume contamination tests indicated the presence of liquid phase contaminant in the form of droplets. Their origin is attributed to incomplete combustion. Most of liquid-phase contaminant is generated during the startup and shutdown (unsteady) periods of thruster pulse. These periods are relatively short (typically 10-50 ms), and the amount of contaminant is determined by the thruster design (propellant valve response, combustion chamber size, thruster mass flow rate, film cooling percentage, dribble volume, etc.) and combustion process organization. Steady-state period of pulse is characterized by much lower contamination rates, but may be lengthy enough to significantly conh'ibute to the overall contamination effect. Because there was no standard methodology for thruster pulse time division, plume contamination tests were conducted at various pulse durations, and their results do not allow quantifying contaminant amounts from each portion of the pulse. At present, the ISS plume contamination model uses an assumption that all thrusters operate in a pulse mode with the pulse length being 100 ms. This assumption may lead to a large difference between the actual amounts of contaminant produced by the thruster and the model predictions. This paper suggests a way to standardize thruster startup and shutdown period definitions, and shows the usefulness of this approach to better quantify thruster plume contamination. Use of the suggested thruster pulse time-division technique will ensure methodological consistency of future thruster plume contamination test programs

  11. Malaria Genome Sequencing Project

    Science.gov (United States)

    2004-01-01

    breaks (for example, VDJ recombination in the immune system in present. humans). The role of NHEJ in repairing radiation-induced double The var genes...there are also a number of pseudogenes and gene truncations breaks (for example, VDJ recombination in the immune system in present. humans). The role...protective efficacy of recombinant antigen constructs 16,17 Salvador I chromosomes can be separated by pulsed-field gel electrophoresis for karyotype and

  12. Increasing Flexibility in Two-Dimensional Liquid Chromatography by Pulsed Elution of the First Dimension: A Proof of Concept.

    Science.gov (United States)

    Jakobsen, Simon S; Christensen, Jan H; Verdier, Sylvain; Mallet, Claude R; Nielsen, Nikoline J

    2017-09-05

    This work demonstrates the development of an online two-dimensional liquid chromatography (2D-LC) method where the first dimension column is eluted by a sequence of pulses of increasing eluotropic strength generated by the LC pumps (pulsed-elution 2D-LC). Between the pulses, the first dimension is kept in a no-elution state using low eluent strength. The eluate from the first dimension is actively modulated using trap columns and subsequently analyzed in the second dimension. We demonstrate that by tuning the length and eluotropic strength of the pulses, peaks with retention factors in water, kw, above 150 can be manipulated to elute in 3-4 pulses. The no-elution state can be kept for 1-10 min with only minor changes as to which and how many pulses the peaks elute in. Pulsed-elution 2D-LC combined with active modulation tackles three of the main challenges encountered in 2D-LC and specifically online comprehensive 2D-LC: undersampling, difficulties in refocusing, and lack of flexibility in the selection of column dimensions and flow rates because the two dimensions constrain each other. The pulsed-elution 2D-LC was applied for the analysis of a basic fraction of vacuum gas oil. Peak capacity was 4018 for a 540 min analysis and 4610 for a 1040 min analysis.

  13. AMXP Pulse variability wih NICER

    Science.gov (United States)

    Bult, Peter

    2017-08-01

    Accreting millisecond X-ray pulsars show a diverse scope variability, including coherent pulsations from the stellar surface and quasi-periodic oscillations attributed to the accretion flow. Because the pulsations are ultimately powered by accreting material, it may be expected that these periodic and quasi-periodic signals show coupled behavior. Observing and characterizing such coupling then gives a unique view of the flow of matter in the closest vicinity of the neutron star surface. In this contribution I will present recently developed specialized methods that can detect such coupling, and discuss how high quality X-ray observations by NICER may enable pulse amplitude modulation studies, and their potential to constrain the physics of accretion.

  14. Academic Training - Pulsed SC Magnets

    CERN Multimedia

    Françoise Benz

    2006-01-01

    2005-2006 ACADEMIC TRAINING PROGRAMME LECTURE SERIES 2, 3, June 29, 30, 31 May, 1, 2 June 11:00-12:00 - Auditorium, bldg 500 Pulsed SC Magnets by M. Wilson Lecture 1. Introduction to Superconducting Materials Type 1,2 and high temperature superconductors; their critical temperature, field & current density. Persistent screening currents and the critical state model. Lecture 2. Magnetization and AC Loss How screening currents cause irreversible magnetization and hysteresis loops. Field errors caused by screening currents. Flux jumping. The general formulation of ac loss in terms of magnetization. AC losses caused by screening currents. Lecture 3. Twisted Wires and Cables Filamentary composite wires and the losses caused by coupling currents between filaments, the need for twisting. Why we need cables and how the coupling currents in cables contribute more ac loss. Field errors caused by coupling currents. Lecture 4. AC Losses in Magnets, Cooling and Measurement Summary of all loss mech...

  15. The Body as a Pulse

    Directory of Open Access Journals (Sweden)

    Flavia Liberman

    2010-01-01

    Full Text Available The body is the focus of many studies and interventions. Some paradigms conceptualize the body only in relation to its motor-sensory characteristics, while others prioritize its psychological dimensions. With the aim of contributing towards formulating other perspectives within this field, some aspects of Stanley Keleman and Regina Favre's conceptualization of the body are presented here. Starting from clinical situations during seminar groups, we can take the body to be a multifaceted multimedia pulse that is continually [de]constructed through encounters. Together with the author's clinical experiences as an occupational therapist and teacher or undergraduates, these conceptualizations serve as a guide to clinical practice that is thought out, constructed and balanced by the body, using body approaches to promote encounters molded by affections and events, in an attempt to create bodies capable of sustaining the lived intensity of experiences, and which enable self-observation, closeness to other people and production of singularities.

  16. Ranchero Explosive Pulsed Power Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Goforth, J.H.; Atchison, W.L.; Deninger, W.J.; Fowler, C.M.; Herrera, D.H.; King, J.C.; Lopez, E.A.; Oona, H.; Reinovsky, R.E.; Stokes, J.L.; Sena, F.C.; Tabaka, L.J.; Tasker, D.G.; Torres, D.T.; Lindemuth, I.R.; Faehl, R.J.; Keinigs, R.K.; Taylor, A.J.; Rodriguez, G.; Oro, D.M.; Garcia, O.F.; parker, J.V.; Broste, W.B.

    1999-06-27

    The authors are developing the Ranchero high explosive pulsed power (HEPP) system to power cylindrically imploding solid-density liners for hydrodynamics experiments. The near-term goal is to conduct experiments in the regime pertinent to the Atlas Capacitor bank. That is, they will attempt to implode liners of {approximately}50 g mass at velocities approaching 15 km/sec. The basic building block of the HEPP system is a coaxial generator with a 304.8 mm diameter stator, and an initial armature diameter of 152 mm. The armature is expanded by a high explosive (HE) charge detonated simultaneously along its axis. They have reported a variety of experiments conducted with generator modules 43 cm long and have presented an initial design for hydrodynamic liner experiments. In this paper they give a synopsis of their first system test, and a status report on the development of a generator module that is 1.4 m long.

  17. RANCHERO explosive pulsed power experiments

    CERN Document Server

    Goforth, J H; Armijo, E V; Atchison, W L; Bartos, Yu; Clark, D A; Day, R D; Deninger, W J; Faehl, R J; Fowler, C M; García, F P; García, O F; Herrera, D H; Herrera, T J; Keinigs, R K; King, J C; Lindemuth, I R; López, E; Martínez, E C; Martínez, D; McGuire, J A; Morgan, D; Oona, H; Oro, D M; Parker, J V; Randolph, R B; Reinovsky, R E; Rodríguez, G; Stokes, J L; Sena, F C; Tabaka, L J; Tasker, D G; Taylor, A J; Torres, D T; Anderson, H D; Broste, W B; Johnson, J B; Kirbie, H C

    1999-01-01

    The authors are developing the RANCHERO high explosive pulsed power (HEPP) system to power cylindrically imploding solid-density liners for hydrodynamics experiments. Their near-term goal is to conduct experiments in the regime pertinent to the Atlas capacitor bank. That is, they will attempt to implode liners of ~50 g mass at velocities approaching 15 km/sec. The basic building block of the HEPP system is a coaxial generator with a 304.8 mm diameter stator, and an initial armature diameter of 152 mm. The armature is expanded by a high explosive (HE) charge detonated simultaneously along its axis. The authors have reported a variety of experiments conducted with generator modules 43 cm long and have presented an initial design for hydrodynamic liner experiments. In this paper, they give a synopsis of their first system test, and a status report on the development of a generator module that is 1.4 m long. (6 refs).

  18. The effect of excitation and preparation pulses on nonslice selective 2D UTE bicomponent analysis of bound and free water in cortical bone at 3T

    Energy Technology Data Exchange (ETDEWEB)

    Li, Shihong [Department of Radiology, University of California, San Diego, California 92103-8226 (United States); Department of Radiology, Hua Dong Hospital, Fudan University, Shanghai 200040 (China); Yancheng Medical College, Jiangsu (China); The First People' s Hospital of Yancheng City, Jiangsu 224005 (China); Chang, Eric Y.; Chung, Christine B. [VA San Diego Healthcare System, San Diego, California 92161 and Department of Radiology, University of California, San Diego, California 92103-8226 (United States); Bae, Won C.; Du, Jiang, E-mail: jiangdu@ucsd.edu [Department of Radiology, University of California, San Diego, California 92103-8226 (United States); Hua, Yanqing [Department of Radiology, Hua Dong Hospital, Fudan University, Shanghai 200040 (China); Zhou, Yi [The First People' s Hospital of Yancheng City, Jiangsu 224005 (China)

    2014-02-15

    Purpose: The purpose of this study was to investigate the effect of excitation, fat saturation, long T2 saturation, and adiabatic inversion pulses on ultrashort echo time (UTE) imaging with bicomponent analysis of bound and free water in cortical bone for potential applications in osteoporosis. Methods: Six bovine cortical bones and six human tibial midshaft samples were harvested for this study. Each bone sample was imaged with eight sequences using 2D UTE imaging at 3T with half and hard excitation pulses, without and with fat saturation, long T2 saturation, and adiabatic inversion recovery (IR) preparation pulses. Single- and bicomponent signal models were utilized to calculate the T2{sup *}s and/or relative fractions of short and long T2{sup *}s. Results: For all bone samples UTE T2{sup *} signal decay showed bicomponent behavior. A higher short T2{sup *} fraction was observed on UTE images with hard pulse excitation compared with half pulse excitation (75.6% vs 68.8% in bovine bone, 79.9% vs 73.2% in human bone). Fat saturation pulses slightly reduced the short T2{sup *} fraction relative to regular UTE sequences (5.0% and 2.0% reduction, respectively, with half and hard excitation pulses for bovine bone, 6.3% and 8.2% reduction, respectively, with half and hard excitation pulses for human bone). Long T2 saturation pulses significantly reduced the long T2{sup *} fraction relative to regular UTE sequence (18.9% and 17.2% reduction, respectively, with half and hard excitation pulses for bovine bone, 26.4% and 27.7% reduction, respectively, with half and hard excitation pulses for human bone). With IR-UTE preparation the long T2{sup *} components were significantly reduced relative to regular UTE sequence (75.3% and 66.4% reduction, respectively, with half and hard excitation pulses for bovine bone, 87.7% and 90.3% reduction, respectively, with half and hard excitation pulses for human bone). Conclusions: Bound and free water T2{sup *}s and relative fractions can

  19. Mapping sequences by parts

    Directory of Open Access Journals (Sweden)

    Guziolowski Carito

    2007-09-01

    Full Text Available Abstract Background: We present the N-map method, a pairwise and asymmetrical approach which allows us to compare sequences by taking into account evolutionary events that produce shuffled, reversed or repeated elements. Basically, the optimal N-map of a sequence s over a sequence t is the best way of partitioning the first sequence into N parts and placing them, possibly complementary reversed, over the second sequence in order to maximize the sum of their gapless alignment scores. Results: We introduce an algorithm computing an optimal N-map with time complexity O (|s| × |t| × N using O (|s| × |t| × N memory space. Among all the numbers of parts taken in a reasonable range, we select the value N for which the optimal N-map has the most significant score. To evaluate this significance, we study the empirical distributions of the scores of optimal N-maps and show that they can be approximated by normal distributions with a reasonable accuracy. We test the functionality of the approach over random sequences on which we apply artificial evolutionary events. Practical Application: The method is illustrated with four case studies of pairs of sequences involving non-standard evolutionary events.

  20. HIV Sequence Compendium 2015

    Energy Technology Data Exchange (ETDEWEB)

    Foley, Brian Thomas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Leitner, Thomas Kenneth [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Apetrei, Cristian [Univ. of Pittsburgh, PA (United States); Hahn, Beatrice [Univ. of Pennsylvania, Philadelphia, PA (United States); Mizrachi, Ilene [National Center for Biotechnology Information, Bethesda, MD (United States); Mullins, James [Univ. of Washington, Seattle, WA (United States); Rambaut, Andrew [Univ. of Edinburgh, Scotland (United Kingdom); Wolinsky, Steven [Northwestern Univ., Evanston, IL (United States); Korber, Bette Tina Marie [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-10-05

    This compendium is an annual printed summary of the data contained in the HIV sequence database. We try to present a judicious selection of the data in such a way that it is of maximum utility to HIV researchers. Each of the alignments attempts to display the genetic variability within the different species, groups and subtypes of the virus. This compendium contains sequences published before January 1, 2015. Hence, though it is published in 2015 and called the 2015 Compendium, its contents correspond to the 2014 curated alignments on our website. The number of sequences in the HIV database is still increasing. In total, at the end of 2014, there were 624,121 sequences in the HIV Sequence Database, an increase of 7% since the previous year. This is the first year that the number of new sequences added to the database has decreased compared to the previous year. The number of near complete genomes (>7000 nucleotides) increased to 5834 by end of 2014. However, as in previous years, the compendium alignments contain only a fraction of these. A more complete version of all alignments is available on our website, http://www.hiv.lanl.gov/ content/sequence/NEWALIGN/align.html As always, we are open to complaints and suggestions for improvement. Inquiries and comments regarding the compendium should be addressed to seq-info@lanl.gov.

  1. Evolution of DNA sequencing.

    Science.gov (United States)

    Tipu, Hamid Nawaz; Shabbir, Ambreen

    2015-03-01

    Sanger and coworkers introduced DNA sequencing in 1970s for the first time. It principally relied on termination of growing nucleotide chain when a dideoxythymidine triphosphate (ddTTP) was inserted in it. Detection of terminated sequences was done radiographically on Polyacrylamide Gel Electrophoresis (PAGE). Improvements that have evolved over time in original Sanger sequencing include replacement of radiography with fluorescence, use of separate fluorescent markers for each nucleotide, use of capillary electrophoresis instead of polyacrylamide gel electrophoresis and then introduction of capillary array electrophoresis. However, this technique suffered from few inherent limitations like decreased sensitivity for low level mutant alleles, complexities in analyzing highly polymorphic regions like Major Histocompatibility Complex (MHC) and high DNA concentrations required. Several Next Generation Sequencing (NGS) technologies have been introduced by Roche, Illumina and other commercial manufacturers that tend to overcome Sanger sequencing limitations and have been reviewed. Introduction of NGS in clinical research and medical diagnostics is expected to change entire diagnostic approach. These include study of cancer variants, detection of minimal residual disease, exome sequencing, detection of Single Nucleotide Polymorphisms (SNPs) and their disease association, epigenetic regulation of gene expression and sequencing of microorganisms genome.

  2. Aerospace applications of pulsed plasmas

    Science.gov (United States)

    Starikovskiy, Andrey

    2012-10-01

    The use of a thermal equilibrium plasma for combustion control dates back more than a hundred years to the advent of internal combustion (IC) engines and spark ignition systems. The same principles are still applied today to achieve high efficiency in various applications. Recently, the potential use of nonequilibrium plasma for ignition and combustion control has garnered increasing interest due to the possibility of plasma-assisted approaches for ignition and flame stabilization. During the past decade, significant progress has been made toward understanding the mechanisms of plasma chemistry interactions, energy redistribution and the nonequilibrium initiation of combustion. In addition, a wide variety of fuels have been examined using various types of discharge plasmas. Plasma application has been shown to provide additional combustion control, which is necessary for ultra-lean flames, high-speed flows, cold low-pressure conditions of high-altitude gas turbine engine (GTE) relight, detonation initiation in pulsed detonation engines (PDE) and distributed ignition control in homogeneous charge-compression ignition (HCCI) engines, among others. The present paper describes the current understanding of the nonequilibrium excitation of combustible mixtures by electrical discharges and plasma-assisted ignition and combustion. Nonequilibrium plasma demonstrates an ability to control ultra-lean, ultra-fast, low-temperature flames and appears to be an extremely promising technology for a wide range of applications, including aviation GTEs, piston engines, ramjets, scramjets and detonation initiation for pulsed detonation engines. To use nonequilibrium plasma for ignition and combustion in real energetic systems, one must understand the mechanisms of plasma-assisted ignition and combustion and be able to numerically simulate the discharge and combustion processes under various conditions.

  3. The influence of ultra-fast temporal energy regulation on the morphology of Si surfaces through femtosecond double pulse laser irradiation

    Science.gov (United States)

    Barberoglou, M.; Tsibidis, G. D.; Gray, D.; Magoulakis, E.; Fotakis, C.; Stratakis, E.; Loukakos, P. A.

    2013-11-01

    The effect of ultra-short laser-induced morphological changes upon irradiation of silicon with double pulse sequences is investigated under conditions that lead to mass removal. The temporal delay between 12 double and equal-energy pulses ( E p=0.24 J/cm2 each, with pulse duration t p=430 fs, 800 nm laser wavelength) was varied between 0 and 14 ps and a decrease of the damaged area, crater depth size and periodicity of the induced subwavelength ripples (by 3-4 %) was observed with increasing pulse delay. The proposed underlying mechanism is based on the combination of carrier excitation and energy thermalization and capillary wave solidification and aims to provide an alternative explanation of the control of ripple periodicity by temporal pulse tailoring. This work demonstrates the potential of pulse shaping technology to improve ultra-fast laser-assisted micro/nanoprocessing.

  4. Pulse splitting in light propagation through N -type atomic media due to an interplay of Kerr nonlinearity and group-velocity dispersion

    Science.gov (United States)

    Rajitha K., V.; Dey, Tarak N.; Evers, Jörg; Kiffner, Martin

    2015-08-01

    We investigate the spatiotemporal evolution of a Gaussian probe pulse propagating through a four-level N -type atomic medium. At two-photon resonance of probe and control fields, weaker probe pulses may propagate through the medium with low absorption and pulse shape distortion. In contrast, we find that increasing the probe pulse intensity leads to a splitting of the initially Gaussian pulse into a sequence of subpulses in the time domain. The number of subpulses arising throughout the propagation can be controlled via a suitable choice of the probe and control field parameters. Employing a simple theoretical model for the nonlinear pulse propagation, we conclude that the splitting occurs due to an interplay of Kerr nonlinearity and group-velocity dispersion.

  5. Selective excitation of multiple Raman Stokes wavelengths (green-yellow-red) using shaped multi-step pulses from an all-fiber PM MOPA.

    Science.gov (United States)

    Lin, Dejiao; Alam, Shaif-ul; Teh, Peh Siong; Chen, Kang Kang; Richardson, David J

    2011-01-31

    We report a rapidly tunable, wavelength agile fiber laser system capable of the synchronous generation of sequences of pulses with different wavelengths in the visible region of the spectrum using stimulated Raman scattering of multi-step pump pulses in a 250 m length of fiber. The frequency doubled output of a single polarization all-fiber Yb-doped MOPA operating at 1060 nm was used as the pump source. By adjusting the pump power and the pulse profiles we achieved the sequential excitation of green (1st Stokes), yellow (4th Stokes) and red light (6th Stokes) using 3-step pulses, or the combination of any two using 2-step pulses. The wavelength switching time was <5 ns and was limited only by the pulse shaping drive electronics.

  6. Simultaneous excitation of selective multiple Raman Stokes wavelengths (green-yellow-red) using shaped multi-step pulses from an all-fiber MOPA system

    Science.gov (United States)

    Lin, Dejiao; Alam, Shaif-ul; Teh, Peh Siong; Chen, Kang Kang; Richardson, David J.

    2011-02-01

    We report the simultaneous excitation of multiple Raman Stokes lines in a 250 m long fiber using multi-step pump pulses. The frequency doubled output of a single polarization all-fiber Yb-doped MOPA operating at 1060 nm was used as the pump source. By adjusting the pump power and the pulse profiles we achieved the simultaneous excitation of green (1st Stokes), yellow (4th Stokes) and red light (6th Stokes) using 3-step pulses or the combination of any two using 2-step pulses. Through the use of pulse shaping we generate sequences of colored pulses with the flexibility of providing dynamic, agile frequency tuning between well-defined wavelengths.

  7. Laser system using ultra-short laser pulses

    Science.gov (United States)

    Dantus, Marcos [Okemos, MI; Lozovoy, Vadim V [Okemos, MI; Comstock, Matthew [Milford, MI

    2009-10-27

    A laser system using ultrashort laser pulses is provided. In another aspect of the present invention, the system includes a laser, pulse shaper and detection device. A further aspect of the present invention employs a femtosecond laser and binary pulse shaping (BPS). Still another aspect of the present invention uses a laser beam pulse, a pulse shaper and a SHG crystal.

  8. Generation of synchronized signal and pump pulses for an optical ...

    Indian Academy of Sciences (India)

    Abstract. Synchronized signal (650 ps) and pump (1.3 ns) pulses were generated using. 4-pass geometry in a grating pair based pulse stretcher unit. The pump pulse has been further amplified in a high gain regenerative amplifier. This amplified pulse was used as the pump in an optical parametric chirped pulse ...

  9. High-Altitude Electromagnetic Pulse (HEMP) Testing

    Science.gov (United States)

    2015-07-09

    Final 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Test Operations Procedure (TOP) 01-2-620A High-Altitude Electromagnetic Pulse ( HEMP ...planning and execution of testing Army/DOD equipment to determine the effects of Horizontal Component High Altitude Electromagnetic Pulse ( HEMP ...5 2.3 HEMP Pre/Post Test Illuminations ..................................................... 7 3. REQUIRED TEST

  10. Fast Heat Pulse Propagation by Turbulence Spreading

    DEFF Research Database (Denmark)

    Naulin, Volker; Juul Rasmussen, Jens; Mantica, Paola

    2009-01-01

    The propagation of a cold pulse initiated by edge cooling in JET is compared to propagation of the heat wave originating from a modulation of the heating source roughly at mid radius. It is found that the propagation of the cold pulse is by far faster than what could be predicted on the basis of ...

  11. Field mapping of ballistic pressure pulse sources

    Directory of Open Access Journals (Sweden)

    Rad Abtin Jamshidi

    2015-09-01

    Full Text Available Ballistic pressure pulse sources are used since late 1990s for the extracorporeal treatment of chronic Enthesitis. Newly indications are found in trigger-point-therapy for the treatment of musculoskeletal disorders. In both applications excellent results without relevant side effects were found in clinical trials. The technical principle of pressure pulse source is based on the same techniques used in air guns. A projectile is accelerated by pressurized air and hits the applicator with high kinetic energy. By this a compression wave travels through the material and induces a fast (4..5μs, almost singular pressure pulse of 2..10 MPa, which is followed by an equally short rarefaction phase of about the same amplitude. It is assumed that the pressure pulse accounts for the biomedical effects of the device. The slower inertial motion of the waveguide is damped by elastic stoppers, but still can be measured several micro seconds after the initial pressure pulse. In order to characterize the pressure pulse devices, field mapping is performed on several radial pressure pulse sources using the fiber optic hydrophone and a polyvinylidenfluorid (PVDF piezoelectric hydrophone. It could be shown that the current standard (IEC 61846 is not appropriate for characterization of ballistic pressure pulse sources.

  12. Pulsed laser deposition: metal versus oxide ablation

    NARCIS (Netherlands)

    Doeswijk, L.M.; Rijnders, Augustinus J.H.M.; Blank, David H.A.

    2004-01-01

    We present experimental results of pulsed laser interaction with metal (Ni, Fe, Nb) and oxide (TiO2, SrTiO3, BaTiO3) targets. The influence of the laser fluence and the number of laser pulses on the resulting target morphology are discussed. Although different responses for metal and oxide targets

  13. Nasal pulse oximetry overestimates oxygen saturation

    DEFF Research Database (Denmark)

    Rosenberg, J; Pedersen, M H

    1990-01-01

    Ten surgical patients were monitored with nasal and finger pulse oximetry (Nellcor N-200) for five study periods with alternating mouth and nasal breathing and switching of cables and sensors. Nasal pulse oximetry was found to overestimate arterial oxygen saturation by 4.7 (SD 1.4%) (bias...

  14. Pulsed electric field inactivation in a microreactor

    NARCIS (Netherlands)

    Fox, M.B.

    2006-01-01

    Pulsed electric fields (PEF) is a novel, non-thermal pasteurization method which uses short, high electric field pulses to inactivate microorganisms. The advantage of a pasteurization method like PEF compared to regular heat pasteurization is that the taste, flavour, texture and nutritional value

  15. High reliability low jitter pulse generator

    Science.gov (United States)

    Savage, Mark E.; Stoltzfus, Brian S.

    2013-01-01

    A method and concomitant apparatus for generating pulses comprising providing a laser light source, disposing a voltage electrode between ground electrodes, generating laser sparks using the laser light source via laser spark gaps between the voltage electrode and the ground electrodes, and outputting pulses via one or more insulated ground connectors connected to the voltage electrode.

  16. Spectral Lag Evolution among -Ray Burst Pulses

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... We analyse the spectral lag evolution of -ray burst (GRB) pulses with observations by CGRO/BATSE. No universal spectral lag evolution feature and pulse luminosity-lag relation within a GRB is observed.Our results suggest that the spectral lag would be due to radiation physics and dynamics of a given ...

  17. Influence of pulse electrodeposition parameters on microhardness ...

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 39; Issue 5. Influence of ... size rose. The optimum value for pulse frequency was about 25 Hz. Results showed that microhardness of nanocomposite coatings which were produced by pulse current method was higher than that of produced by direct currentmethod.

  18. Development of pulse diagnostic devices in Korea

    Directory of Open Access Journals (Sweden)

    Hyunho Kim

    2013-03-01

    Full Text Available In Korean medicine, pulse diagnosis is one of the important methods for determining the health status of a patient. For over 40 years, electromechanical pulse diagnostic devices have been developed to objectify and quantify pulse diagnoses. In this paper, we review previous research and development for pulse diagnostic devices according to various fields of study: demand analysis and current phase, literature studies, sensors, actuators, systems, physical quantity studies, clinical studies, and the U-health system. We point out some confusing issues that have been naively accepted without strict verification: original pressure pulse waveform and derivative pressure pulse waveform, pressure signals and other signal types, and minutely controlled pressure exertion issues. We then consider some technical and clinical issues to achieve the development of a pulse diagnostic device that is appropriate both technically and in terms of Korean medicine. We hope to show the history of pulse diagnostic device research in Korea and propose a proper method to research and develop these devices.

  19. Estimation of pulse heights and arrival times

    NARCIS (Netherlands)

    Kwakernaak, H.

    1980-01-01

    The problem is studied of estimating the arrival times and heights of pulses of known shape observed with white additive noise. The main difficulty is estimating the number of pulses. When a maximum likelihood formulation is employed for the estimation problem, difficulties similar to the problem of

  20. AN UPDATE ON NIF PULSED POWER

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, P A; James, G F; Petersen, D E; Pendleton, D L; McHale, G B; Barbosa, F; Runtal, A S; Stratton, P L

    2009-06-22

    The National Ignition Facility (NIF) is a 192-beam laser fusion driver operating at Lawrence Livermore National Laboratory. NIF relies on three large-scale pulsed power systems to achieve its goals: the Power Conditioning Unit (PCU), which provides flashlamp excitation for the laser's injection system; the Power Conditioning System (PCS), which provides the multi-megajoule pulsed excitation required to drive flashlamps in the laser's optical amplifiers; and the Plasma Electrode Pockels Cell (PEPC), which enables NIF to take advantage of a fourpass main amplifier. Years of production, installation, and commissioning of the three NIF pulsed power systems are now complete. Seven-day-per-week operation of the laser has commenced, with the three pulsed power systems providing routine support of laser operations. We present the details of the status and operational experience associated with the three systems along with a projection of the future for NIF pulsed power.

  1. Digital gate pulse generator for cycloconverter control

    Science.gov (United States)

    Klein, Frederick F.; Mutone, Gioacchino A.

    1989-01-01

    The present invention provides a digital gate pulse generator which controls the output of a cycloconverter used for electrical power conversion applications by determining the timing and delivery of the firing pulses to the switching devices in the cycloconverter. Previous gate pulse generators have been built with largely analog or discrete digital circuitry which require many precision components and periodic adjustment. The gate pulse generator of the present invention utilizes digital techniques and a predetermined series of values to develop the necessary timing signals for firing the switching device. Each timing signal is compared with a reference signal to determine the exact firing time. The present invention is significantly more compact than previous gate pulse generators, responds quickly to changes in the output demand and requires only one precision component and no adjustments.

  2. Pulse Shepherding in Nonlinear Fiber Optics

    Science.gov (United States)

    Yeh, C.; Bergman, L.

    1996-01-01

    In a wavelength division multiplexed fiber system, where pulses on different wavelength beams may co-propagate in a single mode fiber, the cross-phase-modulation (CPM) effects caused by the nonlinearity of the optical fiber are unavoidable. In other words, pulses on different wavelength beams can interact with and affect each other through the intensity dependence of the refractive index of the fiber. Although CPM will not cause energy to be exchanged among the beams, the pulse shapes and locations on these beams can be altered significantly. This phenomenon makes possible the manipulation and control of pulses co-propagating on different wavelength beams through the introduction of a shepherd pulse at a separate wavelength. How this can be accomplished is demonstrated in this paper.

  3. Exawatt-Zettawatt Pulse Generation and Applications

    CERN Document Server

    Mourou, G A; Malkin, V M; Toroker, Z; Khazanov, E A; Sergeev, A M; Tajima, T

    2011-01-01

    A new amplification method, weaving the three basic compression techniques, Chirped Pulse Amplification (CPA), Optical Parametric Chirped Pulse Amplification (OPCPA) and Plasma Compression by Backward Raman Amplification (BRA) in plasma, is proposed. It is called C3 for Cascaded Conversion Compression. It has the capability to compress with good efficiency kilojoule to megajoule, nanosecond laser pulses into femtosecond pulses, to produce exawatt and beyond peak power. In the future, C3 could be used at large-scale facilities such as the National Ignition Facility (NIF) or the Laser Megajoule (LMJ) and open the way to zettawatt level pulses. The beam will be focused to a wavelength spot size with a f#1. The very small beam size, i.e. few centimeters, along with the low laser repetition rate laser system will make possible the use of inexpensive, precision, disposable optics. The resulting intensity will approach the Schwinger value, thus opening up new possibilities in fundamental physics.

  4. Methods for High Power EM Pulse Measurement

    Directory of Open Access Journals (Sweden)

    P. Fiala

    2006-12-01

    Full Text Available There are some suitable methods for the measurement of ultra-short solitary electromagnetic pulses that can be generated by high power pulsed generators. The measurement methods properties have to correspond to the fact whether we want to measure pulses of voltage, current or free-space electromagnetic wave. The need for specific measurement methods occurred by the development of high power microwave pulse generator. Applicable methods are presented in this paper. The method utilizing Faraday's induction law allows the measurement of generated current. For the same purpose the magneto-optic method can be utilized, with its advantages. For measurement of output microwave pulse of the generator the calorimetric method was designed and realized.

  5. One laser pulse generates two photoacoustic signals

    CERN Document Server

    Gao, Fei; Zheng, Yuanjin

    2016-01-01

    Photoacoustic sensing and imaging techniques have been studied widely to explore optical absorption contrast based on nanosecond laser illumination. In this paper, we report a long laser pulse induced dual photoacoustic (LDPA) nonlinear effect, which originates from unsatisfied stress and thermal confinements. Being different from conventional short laser pulse illumination, the proposed method utilizes a long square-profile laser pulse to induce dual photoacoustic signals. Without satisfying the stress confinement, the dual photoacoustic signals are generated following the positive and negative edges of the long laser pulse. More interestingly, the first expansion-induced photoacoustic signal exhibits positive waveform due to the initial sharp rising of temperature. On the contrary, the second contraction-induced photoacoustic signal exhibits exactly negative waveform due to the falling of temperature, as well as pulse-width-dependent, signal amplitude which is caused by the concurrent heat accumulation and ...

  6. Description of pulse propagation in a dispersive medium by use of a pulse quality factor.

    Science.gov (United States)

    Rousseau, Guy; McCarthy, Nathalie; Pichãé, Michel

    2002-09-15

    We investigated how the duration of short laser pulses evolves in a dispersive material, using rms widths and a propagation law based on a pulse quality factor. Experiments were carried out with femtosecond pulses (10 to 25fs at the temporal waist) propagating in bulk fused silica. Excellent agreement was found between theory and experiment. This approach does not require complete characterization of laser pulses and eliminates the need for any assumption regarding the interpretation of autocorrelation traces. The method is of general validity, and it can be applied to pulses of arbitrary shape.

  7. Delayed Sequence Intubation

    DEFF Research Database (Denmark)

    Weingart, Scott D; Trueger, N Seth; Wong, Nelson

    2015-01-01

    , patients were paralyzed and intubated. The primary outcome of this study was the difference in oxygen saturations after maximal attempts at preoxygenation before delayed sequence intubation compared with saturations just before intubation. Predetermined secondary outcomes and complications were also...... assessed. RESULTS: A total of 62 patients were enrolled: 19 patients required delayed sequence intubation to allow nonrebreather mask, 39 patients required it to allow NIPPV, and 4 patients required it for nasogastric tube placement. Saturations increased from a mean of 89.9% before delayed sequence...... intubation to 98.8% afterward, with an increase of 8.9% (95% confidence interval 6.4% to 10.9%). Thirty-two patients were in a predetermined group with high potential for critical desaturation (pre-delayed sequence intubation saturations ≤93%). All of these patients increased their saturations post...

  8. Gomphid DNA sequence data

    Data.gov (United States)

    U.S. Environmental Protection Agency — DNA sequence data for several genetic loci. This dataset is not publicly accessible because: It's already publicly available on GenBank. It can be accessed through...

  9. Random Sequence for Optimal Low-Power Laser Generated Ultrasound

    Science.gov (United States)

    Vangi, D.; Virga, A.; Gulino, M. S.

    2017-08-01

    Low-power laser generated ultrasounds are lately gaining importance in the research world, thanks to the possibility of investigating a mechanical component structural integrity through a non-contact and Non-Destructive Testing (NDT) procedure. The ultrasounds are, however, very low in amplitude, making it necessary to use pre-processing and post-processing operations on the signals to detect them. The cross-correlation technique is used in this work, meaning that a random signal must be used as laser input. For this purpose, a highly random and simple-to-create code called T sequence, capable of enhancing the ultrasound detectability, is introduced (not previously available at the state of the art). Several important parameters which characterize the T sequence can influence the process: the number of pulses Npulses , the pulse duration δ and the distance between pulses dpulses . A Finite Element FE model of a 3 mm steel disk has been initially developed to analytically study the longitudinal ultrasound generation mechanism and the obtainable outputs. Later, experimental tests have shown that the T sequence is highly flexible for ultrasound detection purposes, making it optimal to use high Npulses and δ but low dpulses . In the end, apart from describing all phenomena that arise in the low-power laser generation process, the results of this study are also important for setting up an effective NDT procedure using this technology.

  10. HIV Sequence Compendium 2010

    Energy Technology Data Exchange (ETDEWEB)

    Kuiken, Carla [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Foley, Brian [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Leitner, Thomas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Apetrei, Christian [Univ. of Pittsburgh, PA (United States); Hahn, Beatrice [Univ. of Alabama, Tuscaloosa, AL (United States); Mizrachi, Ilene [National Center for Biotechnology Information, Bethesda, MD (United States); Mullins, James [Univ. of Washington, Seattle, WA (United States); Rambaut, Andrew [Univ. of Edinburgh, Scotland (United Kingdom); Wolinsky, Steven [Northwestern Univ., Evanston, IL (United States); Korber, Bette [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2010-12-31

    This compendium is an annual printed summary of the data contained in the HIV sequence database. In these compendia we try to present a judicious selection of the data in such a way that it is of maximum utility to HIV researchers. Each of the alignments attempts to display the genetic variability within the different species, groups and subtypes of the virus. This compendium contains sequences published before January 1, 2010. Hence, though it is called the 2010 Compendium, its contents correspond to the 2009 curated alignments on our website. The number of sequences in the HIV database is still increasing exponentially. In total, at the time of printing, there were 339,306 sequences in the HIV Sequence Database, an increase of 45% since last year. The number of near complete genomes (>7000 nucleotides) increased to 2576 by end of 2009, reflecting a smaller increase than in previous years. However, as in previous years, the compendium alignments contain only a small fraction of these. Included in the alignments are a small number of sequences representing each of the subtypes and the more prevalent circulating recombinant forms (CRFs) such as 01 and 02, as well as a few outgroup sequences (group O and N and SIV-CPZ). Of the rarer CRFs we included one representative each. A more complete version of all alignments is available on our website, http://www.hiv.lanl.gov/content/sequence/NEWALIGN/align.html. Reprints are available from our website in the form of both HTML and PDF files. As always, we are open to complaints and suggestions for improvement. Inquiries and comments regarding the compendium should be addressed to seq-info@lanl.gov.

  11. What's Decidable About Sequences?

    OpenAIRE

    Furia, Carlo A.

    2010-01-01

    We present a first-order theory of sequences with integer elements, Presburger arithmetic, and regular constraints, which can model significant properties of data structures such as arrays and lists. We give a decision procedure for the quantifier-free fragment, based on an encoding into the first-order theory of concatenation; the procedure has PSPACE complexity. The quantifier-free fragment of the theory of sequences can express properties such as sortedness and injectivity, as well as Bool...

  12. First experimental implementation of pulse shaping for neutron diffraction on pulsed sources

    Energy Technology Data Exchange (ETDEWEB)

    Russina, M. [Helmholtz-Zentrum-Berlin, Hahn-Meitner Platz 1, 14109 Berlin (Germany); Kali, Gy.; Santa, Zs. [HAS Research Institute for Solid State Physics, Konkoly Thege ut. 29-33, 1121 Budapest (Hungary); Mezei, F., E-mail: f.mezei@esshungary.eu [HAS Research Institute for Solid State Physics, Konkoly Thege ut. 29-33, 1121 Budapest (Hungary); European Spallation Source ESS AB, P.O. Box 176, 22100 Lund (Sweden)

    2011-10-21

    One of the central issues in the design and the use of pulsed neutron sources is the control of pulse length in elastic scattering experiments, most significantly diffraction on crystalline matter. On the existing short pulse spallation sources the strongly wavelength dependent source pulse length that determines the resolution is permanently fixed on each beam line by the type of the moderator it faces. We have experimentally implemented for the first time the wavelength frame multiplication (WFM) multiplexing chopper method, an earlier proposed variant of the by now fully tested repetition rate multiplication technique for inelastic scattering spectroscopy on pulsed neutron sources. We have operated the time-of-flight diffractometer at the continuous reactor source at BNC in an unconventional multiplexing mode that emulates a pulsed source. As a full proof of principle of the WFM method we have experimentally demonstrated the extraction from each source pulse a series of polychromatic, chopper shaped neutron pulses, which can continuously cover any wavelength band. The achieved 25 {mu}s FWHM pulse length is shorter than that can be obtained at all at short pulse spallation sources for cold neutrons. The method allows us to build efficient, high and variable resolution diffractometers at long pulse spallation sources.

  13. Unstable and Multiple Pulsing Can Be Invisible to Ultrashort Pulse Measurement Techniques

    Directory of Open Access Journals (Sweden)

    Michelle Rhodes

    2016-12-01

    Full Text Available Multiple pulsing occurs in most ultrashort-pulse laser systems when pumped at excessively high powers, and small fluctuations in pump power in certain regimes can cause unusual variations in the temporal separations of sub-pulses. Unfortunately, the ability of modern intensity-and-phase pulse measurement techniques to measure such unstable multi-pulsing has not been studied. Here we report calculations and simulations finding that allowing variations in just the relative phase of a satellite pulse causes the second pulse to completely disappear from a spectral interferometry for direct electric field reconstruction (SPIDER measurement. We find that, although neither frequency-resolved optical gating (FROG nor autocorrelation can determine the precise properties of satellite pulses due to the presence of instability, they always succeed in, at least, seeing the satellite pulses. Also, additional post-processing of the measured FROG trace can determine the correct approximate relative height of the satellite pulse and definitively indicate the presence of unstable multiple-pulsing.

  14. New Assessment Model of Pulse Depth Based on Sensor Displacement in Pulse Diagnostic Devices

    Directory of Open Access Journals (Sweden)

    Jang-Han Bae

    2013-01-01

    Full Text Available An accurate assessment of the pulse depth in pulse diagnosis is vital to determine the floating and sunken pulse qualities (PQs, which are two of the four most basic PQs. In this work, we proposed a novel model of assessing the pulse depth based on sensor displacement (SD normal to the skin surface and compared this model with two previous models which assessed the pulse depth using contact pressure (CP. In contrast to conventional stepwise CP variation tonometry, we applied a continuously evolving tonometric mechanism at a constant velocity and defined the pulse depth index as the optimal SD where the largest pulse amplitude was observed. By calculating the pulse depth index for 18 volunteers, we showed that the pulse was deepest at Cheok (significance level: P<0.01, while no significant difference was found between Chon and Gwan. In contrast, the two CP-based models estimated that the pulse was shallowest at Gwan (P<0.05. For the repeated measures, the new SD-based model showed a smaller coefficient of variation (CV≈7.6% than the two CP-based models (CV≈13.5% and 12.3%, resp.. The SD-based pulse depth assessment is not sensitive to the complex geometry around the palpation locations and temperature variation of contact sensors, which allows cost-effective sensor technology.

  15. Synchronization of picosecond laser pulses to the target X-ray pulses at SPring-8

    CERN Document Server

    Tanaka, Y; Kitamura, H; Ishikawa, T

    2001-01-01

    Synchronization system between an intense picosecond laser and the target X-ray pulses has been developed at SPring-8. The intense laser pulses were obtained by amplification of the pulses picked up from a mode-locked Ti:sapphire laser synchronized with the radio frequency of the storage ring. The repetition rate of amplified laser pulses was controlled to be 1/n of the RF, where n is a multiple of the number of RF buckets in the ring, so that the laser pulses meet the SR pulses originated from a particular electron bunch in partial filling patterns. The temporal overlap of the laser and the target X-ray pulses was achieved as monitored with a streak camera in synchroscan and repetitive single shot operation modes, and was stable with a precision of a few ps for several hours.

  16. Residual stress reduction by combined treatment of pulsed magnetic field and pulsed current

    Energy Technology Data Exchange (ETDEWEB)

    Cai Zhipeng, E-mail: czpdme@gmail.com [Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Huang Xinquan [Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China)

    2011-07-25

    Highlights: {yields} The combination of magnetic field and current releases stress significantly. {yields} Both magneto and electro-plasticity may exit in the combined treatment. {yields} Stress increase caused by current should be studied later. - Abstract: This paper reports a significant decrease on residual stress by combined treatment of a pulsed magnetic field and a pulse current on steel samples with pre-induced residual stress conditions, compared to a separately single treatment by either the pulsed magnetic field or the pulsed current. Briefly, 10% stress decrease by pulsed magnetic field treatment and 20% increase by pulsed current treatment were observed respectively. While 60% stress release is achieved by the combined treatments, in which the same magnetic field and current parameters were applied. It is supposed that the magnetic field facilitates dislocations depinning and pulsed current provides conduction electrons to drive dislocations to move further and faster. The combined effects lead to electro-magneto-plasticity and further residual stress release.

  17. Pulse front adaptive optics: a new method for control of ultrashort laser pulses.

    Science.gov (United States)

    Sun, Bangshan; Salter, Patrick S; Booth, Martin J

    2015-07-27

    Ultrafast lasers enable a wide range of physics research and the manipulation of short pulses is a critical part of the ultrafast tool kit. Current methods of laser pulse shaping are usually considered separately in either the spatial or the temporal domain, but laser pulses are complex entities existing in four dimensions, so full freedom of manipulation requires advanced forms of spatiotemporal control. We demonstrate through a combination of adaptable diffractive and reflective optical elements - a liquid crystal spatial light modulator (SLM) and a deformable mirror (DM) - decoupled spatial control over the pulse front (temporal group delay) and phase front of an ultra-short pulse was enabled. Pulse front modulation was confirmed through autocorrelation measurements. This new adaptive optics technique, for the first time enabling in principle arbitrary shaping of the pulse front, promises to offer a further level of control for ultrafast lasers.

  18. CTS and CZTS for solar cells made by pulsed laser deposition and pulsed electron deposition

    DEFF Research Database (Denmark)

    Ettlinger, Rebecca Bolt

    This thesis concerns the deposition of thin films for solar cells using pulsed laser deposition (PLD) and pulsed electron deposition (PED). The aim was to deposit copper tin sulfide (CTS) and zinc sulfide (ZnS) by pulsed laser deposition to learn about these materials in relation to copper zinc tin......, which make them promising alternatives to the commercially successful solar cell material copper indium gallium diselenide (CIGS). Complementing our group's work on pulsed laser deposition of CZTS, we collaborated with IMEM-CNR in Parma, Italy, to deposit CZTS by pulsed electron deposition for the first...... of using pulsed electron deposition was to make CZTS at a low processing temperature, avoiding the 570 °C annealing step used for our pulsed laser deposited solar cells. Preliminary solar cells had an efficiency of 0.2 % with a 300 °C deposition step without annealing. Further process control is needed...

  19. Neural mechanisms of sequence generation in songbirds

    Science.gov (United States)

    Langford, Bruce

    Animal models in research are useful for studying more complex behavior. For example, motor sequence generation of actions requiring good muscle coordination such as writing with a pen, playing an instrument, or speaking, may involve the interaction of many areas in the brain, each a complex system in itself; thus it can be difficult to determine causal relationships between neural behavior and the behavior being studied. Birdsong, however, provides an excellent model behavior for motor sequence learning, memory, and generation. The song consists of learned sequences of notes that are spectrographically stereotyped over multiple renditions of the song, similar to syllables in human speech. The main areas of the songbird brain involve in singing are known, however, the mechanisms by which these systems store and produce song are not well understood. We used a custom built, head-mounted, miniature motorized microdrive to chronically record the neural firing patterns of identified neurons in HVC, a pre-motor cortical nucleus which has been shown to be important in song timing. These were done in Bengalese finch which generate a song made up of stereotyped notes but variable note sequences. We observed song related bursting in neurons projecting to Area X, a homologue to basal ganglia, and tonic firing in HVC interneurons. Interneuron had firing rate patterns that were consistent over multiple renditions of the same note sequence. We also designed and built a light-weight, low-powered wireless programmable neural stimulator using Bluetooth Low Energy Protocol. It was able to generate perturbations in the song when current pulses were administered to RA, which projects to the brainstem nucleus responsible for syringeal muscle control.

  20. Entanglement of ions in a uniformly-spaced chain using individual addressing and pulse shaping

    Science.gov (United States)

    Debnath, S.; Manning, T. A.; Choi, T.; Fields, B.; Monroe, C.

    2012-06-01

    We present progress towards entanglement of subsets of ^171Yb^+ ions in a single uniformly-spaced chain using individual optical addressing and simple laser pulse shaping. A pulsed 355 nm laser drives Raman transitions to create a spin-dependent force on individual ions in the chain, where the collective ion motion facilitates the entanglement of the ions' spin states. By coupling to transverse phonon modes instead of axial modes, we will be less sensitive to thermal motion and ion heating, resulting in comparatively higher gate fidelities. Additionally, faster gate speeds are achievable by applying sequences of a few laser pulses at optimized intensities and detuning that couple to multiple modes of motion [1,2]. [4pt] [1] G.-D. Lin, et al. Europhys. Lett. 86, 60004 (2009)[0pt] [2] S-L Zhu, et al., Europhys. Lett. 73, 485-491 (2006)