WorldWideScience

Sample records for pseudo-random test standards

  1. Binary pseudo-random grating as a standard test surface formeasurement of modulation transfer function of interferometricmicroscopes

    Energy Technology Data Exchange (ETDEWEB)

    Yashchuk, Valeriy V.; McKinney, Wayne R.; Takacs, Peter Z.

    2007-07-25

    The task of designing high performance X-ray optical systemsrequires the development of sophisticated X-ray scattering calculationsbased on rigorous information about the optics. One of the mostinsightful approaches to these calculations is based on the powerspectral density (PSD) distribution of the surface height. The majorproblem of measurement of a PSD distribution with an interferometricand/or atomic force microscope arises due to the unknown ModulationTransfer Function (MTF) of the instruments. The MTF characterizes theperturbation of the PSD distribution at higher spatial frequencies. Here,we describe a new method and dedicated test surfaces for calibration ofthe MTF of a microscope. The method is based on use of a speciallydesigned Binary Pseudo-random (BPR) grating. Comparison of atheoretically calculated PSD spectrum of a BPR grating with a spectrummeasured with the grating provides the desired calibration of theinstrumental MTF. The theoretical background of the method, as well asresults of experimental investigations are presented.

  2. BINERY PSEUDO-RANDOM GRATING AS A STANDARD TEST SURFACE FOR MEASUREMENT OF MODULATION TRANSFER FUNCTION OF INTERFEROMETRIC MICROSCOPES.

    Energy Technology Data Exchange (ETDEWEB)

    YASHCHUK,V.V.; MCKINNEY, W.R.; TAKACS, P.Z.

    2007-08-01

    The task of designing high performance X-ray optical systems requires the development of sophisticated X-ray scattering calculations based on rigorous information about the optics. One of the most insightful approaches to these calculations is based on the power spectral density (PSD) distribution of the surface height. The major problem of measurement of a PSD distribution with an interferometric and/or atomic force microscope arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF characterizes the perturbation of the PSD distribution at higher spatial frequencies. Here, we describe a new method and dedicated test surfaces for calibration of the MTF of a microscope. The method is based on use of a specially designed Binary Pseudo-random (BPR) grating. Comparison of a theoretically calculated PSD spectrum of a BPR grating with a spectrum measured with the grating provides the desired calibration of the instrumental MTF. The theoretical background of the method, as well as results of experimental investigations are presented.

  3. Calibration of Modulation Transfer Function of Surface Profilometers with 1D and 2D Binary Pseudo-random Array Standards

    Energy Technology Data Exchange (ETDEWEB)

    Yashchuk, Valeriy V.; McKinney, Wayne R.; Takacs, Peter Z.

    2008-05-19

    We suggest and describe the use of a binary pseudo-random grating as a standard test surface for calibration of the modulation transfer function of microscopes. Results from calibration of a MicromapTM-570 interferometric microscope are presented.

  4. Characterization of Electron Microscopes with Binary Pseudo-random Multilayer Test Samples

    Energy Technology Data Exchange (ETDEWEB)

    V Yashchuk; R Conley; E Anderson; S Barber; N Bouet; W McKinney; P Takacs; D Voronov

    2011-12-31

    Verification of the reliability of metrology data from high quality X-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays has been suggested [1] and [2] and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer [5]. Here we describe the details of development of binary pseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi2/Si multilayer coating with pseudo-randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize X-ray microscopes. Corresponding work with X-ray microscopes is in progress.

  5. Characterization of electron microscopes with binary pseudo-random multilayer test samples

    Energy Technology Data Exchange (ETDEWEB)

    Yashchuk, Valeriy V., E-mail: VVYashchuk@lbl.gov [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Conley, Raymond [NSLS-II, Brookhaven National Laboratory, Upton, NY 11973 (United States); Anderson, Erik H. [Center for X-ray Optics, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Barber, Samuel K. [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Bouet, Nathalie [NSLS-II, Brookhaven National Laboratory, Upton, NY 11973 (United States); McKinney, Wayne R. [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Takacs, Peter Z. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Voronov, Dmitriy L. [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)

    2011-09-01

    Verification of the reliability of metrology data from high quality X-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays has been suggested and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer [5]. Here we describe the details of development of binary pseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi{sub 2}/Si multilayer coating with pseudo-randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize X-ray microscopes. Corresponding work with X-ray microscopes is in progress.

  6. An empirical test of pseudo random number generators by means of an exponential decaying process; Una prueba empirica de generadores de numeros pseudoaleatorios mediante un proceso de decaimiento exponencial

    Energy Technology Data Exchange (ETDEWEB)

    Coronel B, H.F.; Hernandez M, A.R.; Jimenez M, M.A. [Facultad de Fisica e Inteligencia Artificial, Universidad Veracruzana, A.P. 475, Xalapa, Veracruz (Mexico); Mora F, L.E. [CIMAT, A.P. 402, 36000 Guanajuato (Mexico)]. e-mail: hcoronel@uv.mx

    2007-07-01

    Empirical tests for pseudo random number generators based on the use of processes or physical models have been successfully used and are considered as complementary to theoretical tests of randomness. In this work a statistical methodology for evaluating the quality of pseudo random number generators is presented. The method is illustrated in the context of the so-called exponential decay process, using some pseudo random number generators commonly used in physics. (Author)

  7. Cryptography, statistics and pseudo-randomness (Part 1)

    NARCIS (Netherlands)

    Brands, S.; Gill, R.D.

    1995-01-01

    In the classical approach to pseudo-random number generators, a generator is considered to perform well if its output sequences pass a battery of statistical tests that has become standard. In recent years, it has turned out that this approach is not satisfactory. Many generators have turned out to

  8. Pseudo random signal processing theory and application

    CERN Document Server

    Zepernick, Hans-Jurgen

    2013-01-01

    In recent years, pseudo random signal processing has proven to be a critical enabler of modern communication, information, security and measurement systems. The signal's pseudo random, noise-like properties make it vitally important as a tool for protecting against interference, alleviating multipath propagation and allowing the potential of sharing bandwidth with other users. Taking a practical approach to the topic, this text provides a comprehensive and systematic guide to understanding and using pseudo random signals. Covering theoretical principles, design methodologies and applications

  9. A Bidirectional Generalized Synchronization Theorem-Based Chaotic Pseudo-random Number Generator

    Directory of Open Access Journals (Sweden)

    Han Shuangshuang

    2013-07-01

    Full Text Available Based on a bidirectional generalized synchronization theorem for discrete chaos system, this paper introduces a new 5-dimensional bidirectional generalized chaos synchronization system (BGCSDS, whose prototype is a novel chaotic system introduced in [12]. Numerical simulation showed that two pair variables of the BGCSDS achieve generalized chaos synchronization via a transform H.A chaos-based pseudo-random number generator (CPNG was designed by the new BGCSDS. Using the FIPS-140-2 tests issued by the National Institute of Standard and Technology (NIST verified the randomness of the 1000 binary number sequences generated via the CPNG and the RC4 algorithm respectively. The results showed that all the tested sequences passed the FIPS-140-2 tests. The confidence interval analysis showed the statistical properties of the randomness of the sequences generated via the CPNG and the RC4 algorithm do not have significant differences.

  10. Fully Digital Chaotic Oscillators Applied to Pseudo Random Number Generation

    KAUST Repository

    Mansingka, Abhinav S.

    2012-05-01

    adapted for pseudo random number generation by truncating statistically defective bits. Finally, a novel post-processing technique using the Fibonacci series is proposed and implemented with a non-autonomous driven hyperchaotic system to provide pseudo random number generators with high nonlinear complexity and controllable period length that enables full utilization of all branches of the chaotic output as statistically secure pseudo random output.

  11. Concurrent Generation of Pseudo Random Numbers with LFSR of Fibonacci and Galois Type

    OpenAIRE

    Emina I. Milovanović; Stojčev, Mile K.; Igor Ž. Milovanović; Tatjana R. Nikolić; Zoran Stamenković

    2016-01-01

    We have considered implementation of parallel test pattern generator based on a linear feedback shift register (LFSR) with multiple outputs used as a building block in built-in-self-test (BIST) design within SoC. The proposed design can drive several circuits under test (CUT) simultaneously. The mathematical procedure for concurrent pseudo random number (PRN) generation is described. We have implemented LFSRs that generate two and three PRNs in FPGA and ASIC technology. The design was tested ...

  12. Binary Pseudo-Random Gratings and Arrays for Calibration of Modulation Transfer Functions of Surface Profilometers

    Energy Technology Data Exchange (ETDEWEB)

    Barber, Samuel K.; Anderson, Erik D.; Cambie, Rossana; McKinney, Wayne R.; Takacs, Peter Z.; Stover, John C.; Voronov, Dmitriy L.; Yashchuk, Valeriy V.

    2009-09-11

    A technique for precise measurement of the modulation transfer function (MTF), suitable for characterization of a broad class of surface profilometers, is investigated in detail. The technique suggested in [Proc. SPIE 7077-7, (2007), Opt. Eng. 47(7), 073602-1-5 (2008)]is based on use of binary pseudo-random (BPR) gratings and arrays as standard MTF test surfaces. Unlike most conventional test surfaces, BPR gratings and arrays possess white-noise-like inherent power spectral densities (PSD), allowing the direct determination of the one- and two-dimensional MTF, respectively, with a sensitivity uniform over the entire spatial frequency range of a profiler. In the cited work, a one dimensional realization of the suggested method based on use of BPR gratings has been demonstrated. Here, a high-confidence of the MTF calibration technique is demonstrated via cross comparison measurements of a number of two dimensional BPR arrays using two different interferometric microscopes and a scatterometer. We also present the results of application of the experimentally determined MTF correction to the measurement taken with the MicromapTM-570 interferometric microscope of the surface roughness of a super-polished test mirror. In this particular case, without accounting for the instrumental MTF, the surface rms roughness over half of the instrumental spatial frequency bandwidth would be underestimated by a factor of approximately 1.4.

  13. Chaos-based Pseudo-random Number Generation

    KAUST Repository

    Barakat, Mohamed L.

    2014-04-10

    Various methods and systems related to chaos-based pseudo-random number generation are presented. In one example, among others, a system includes a pseudo-random number generator (PRNG) to generate a series of digital outputs and a nonlinear post processing circuit to perform an exclusive OR (XOR) operation on a first portion of a current digital output of the PRNG and a permutated version of a corresponding first portion of a previous post processed output to generate a corresponding first portion of a current post processed output. In another example, a method includes receiving at least a first portion of a current output from a PRNG and performing an XOR operation on the first portion of the current PRNG output with a permutated version of a corresponding first portion of a previous post processed output to generate a corresponding first portion of a current post processed output.

  14. Complexity and properties of a multidimensional Cat-Hadamard map for pseudo random number generation

    Science.gov (United States)

    Kim Hue, Ta Thi; Hoang, Thang Manh

    2017-07-01

    This paper presents a novel method to extend the Cat map from 2-dimension to higher dimension using the fast pseudo Hadamard Transform, and the resulted maps are called Cat-Hadamard maps. The complexity and properties of Cat-Hadamard maps are investigated under the point of view for cryptographic applications. In addition, we propose a method for constructing a pseudo random number generator using a novel design concept of the high dimensional Cat map. The simulation results show that the proposed generator fulfilled all the statistic tests of the NIST SP 800-90 A.

  15. Research of the method of pseudo-random number generation based on asynchronous cellular automata with several active cells

    Directory of Open Access Journals (Sweden)

    Bilan Stepan

    2017-01-01

    Full Text Available To date, there are many tasks that are aimed at studying the dynamic changes in physical processes. These tasks do not give advance known result. The solution of such problems is based on the construction of a dynamic model of the object. Successful structural and functional implementation of the object model can give a positive result in time. This approach uses the task of constructing artificial biological objects. To solve such problems, pseudo-random number generators are used, which also find wide application for information protection tasks. Such generators should have good statistical properties and give a long repetition period of the generated pseudo-random bit sequence. This work is aimed at improving these characteristics. The paper considers the method of forming pseudo-random sequences of numbers on the basis of aperiodic cellular automata with two active cells. A pseudo-random number generator is proposed that generates three bit sequences. The first two bit sequences are formed by the corresponding two active cells in the cellular automaton. The third bit sequence is the result of executing the XOR function over the bits of the first two sequences and it has better characteristics compared to them. The use of cellular automata with two active cells allowed to improve the statistical properties of the formed bit sequence, as well as its repetition period. This is proved by using graphical tests for generators built based on cellular automata using the neighborhoods of von Neumann and Moore. The tests showed high efficiency of the generator based on an asynchronous cellular automaton with the neighborhood of Moore. The proposed pseudo-random number generators have good statistical properties, which makes it possible to use them in information security systems, as well as for simulation tasks of various dynamic processes.

  16. PRIMITIVE MATRICES AND GENERATORS OF PSEUDO RANDOM SEQUENCES OF GALOIS

    Directory of Open Access Journals (Sweden)

    A. Beletsky

    2014-04-01

    Full Text Available In theory and practice of information cryptographic protection one of the key problems is the forming a binary pseudo-random sequences (PRS with a maximum length with acceptable statistical characteristics. PRS generators are usually implemented by linear shift register (LSR of maximum period with linear feedback [1]. In this paper we extend the concept of LSR, assuming that each of its rank (memory cell can be in one of the following condition. Let’s call such registers “generalized linear shift register.” The research goal is to develop algorithms for constructing Galois and Fibonacci generalized matrix of n-order over the field , which uniquely determined both the structure of corresponding generalized of n-order LSR maximal period, and formed on their basis Galois PRS generators of maximum length. Thus the article presents the questions of formation the primitive generalized Fibonacci and Galois arbitrary order matrix over the prime field . The synthesis of matrices is based on the use of irreducible polynomials of degree and primitive elements of the extended field generated by polynomial. The constructing methods of Galois and Fibonacci conjugated primitive matrices are suggested. The using possibilities of such matrices in solving the problem of constructing generalized generators of Galois pseudo-random sequences are discussed.

  17. Improving the pseudo-randomness properties of chaotic maps using deep-zoom.

    Science.gov (United States)

    Machicao, Jeaneth; Bruno, Odemir M

    2017-05-01

    A generalized method is proposed to compose new orbits from a given chaotic map. The method provides an approach to examine discrete-time chaotic maps in a "deep-zoom" manner by using k-digits to the right from the decimal separator of a given point from the underlying chaotic map. Interesting phenomena have been identified. Rapid randomization was observed, i.e., chaotic patterns tend to become indistinguishable when compared to the original orbits of the underlying chaotic map. Our results were presented using different graphical analyses (i.e., time-evolution, bifurcation diagram, Lyapunov exponent, Poincaré diagram, and frequency distribution). Moreover, taking advantage of this randomization improvement, we propose a Pseudo-Random Number Generator (PRNG) based on the k-logistic map. The pseudo-random qualities of the proposed PRNG passed both tests successfully, i.e., DIEHARD and NIST, and were comparable with other traditional PRNGs such as the Mersenne Twister. The results suggest that simple maps such as the logistic map can be considered as good PRNG methods.

  18. Algorithm for generation pseudo-random series with arbitrarily assigned distribution law

    Directory of Open Access Journals (Sweden)

    В.С. Єременко

    2005-04-01

    Full Text Available  Method for generation pseudo-random series with arbitrarily assigned distribution law has been proposed. The praxis of using proposed method for generation pseudo-random series with anti-modal and approximate to Gaussian distribution law has been investigated.

  19. Cryptographic pseudo-random sequences from the chaotic Hénon ...

    Indian Academy of Sciences (India)

    Pseudo-random number sequences are useful in many applications including Monte-Carlo simulation, spread spectrum ... a pseudo-random binary sequence from the two-dimensional chaotic Hénon map is explored. ... is the Hénon map, a two-dimensional discrete-time nonlinear dynamical system represented by the state ...

  20. Protocols for data hiding in pseudo-random state

    Science.gov (United States)

    Craver, Scott; Li, Enping; Yu, Jun

    2009-02-01

    An emerging form of steganographic communication uses ciphertext to replace the output of a random or strong pseudo-random number generator. PRNG-driven media, for example computer animated backdrops in video-conferencing channels, can then be used as a covert channel, if the PRNG bits that generated a piece of content can be estimated by the recipient. However, all bits sent over such a channel must be computationally indistinguishable from i.i.d. coin flips. Ciphertext messages and even key exchange datagrams are easily shaped to match this distribution; however, when placing these messages into a continous stream of PRNG bits, the sender is unable to provide synchronization markers, metadata, or error correction to ensure the message's location and proper decoding. In this paper we explore methods for message transmission and steganographic key exchange in such a "coin flip" channel. We establish that key exchange is generally not possible in this channel if an adversary possesses even a modest noise budget. If the warden is not vigilant in adding noise, however, communication is very simple.

  1. Calibration of Correlation Radiometers Using Pseudo-Random Noise Signals

    Directory of Open Access Journals (Sweden)

    Sebastián Pantoja

    2009-08-01

    Full Text Available The calibration of correlation radiometers, and particularly aperture synthesis interferometric radiometers, is a critical issue to ensure their performance. Current calibration techniques are based on the measurement of the cross-correlation of receivers’ outputs when injecting noise from a common noise source requiring a very stable distribution network. For large interferometric radiometers this centralized noise injection approach is very complex from the point of view of mass, volume and phase/amplitude equalization. Distributed noise injection techniques have been proposed as a feasible alternative, but are unable to correct for the so-called “baseline errors” associated with the particular pair of receivers forming the baseline. In this work it is proposed the use of centralized Pseudo-Random Noise (PRN signals to calibrate correlation radiometers. PRNs are sequences of symbols with a long repetition period that have a flat spectrum over a bandwidth which is determined by the symbol rate. Since their spectrum resembles that of thermal noise, they can be used to calibrate correlation radiometers. At the same time, since these sequences are deterministic, new calibration schemes can be envisaged, such as the correlation of each receiver’s output with a baseband local replica of the PRN sequence, as well as new distribution schemes of calibration signals. This work analyzes the general requirements and performance of using PRN sequences for the calibration of microwave correlation radiometers, and particularizes the study to a potential implementation in a large aperture synthesis radiometer using an optical distribution network.

  2. Calibration of correlation radiometers using pseudo-random noise signals.

    Science.gov (United States)

    Pérez, Isaac Ramos; Bosch-Lluis, Xavi; Camps, Adriano; Alvarez, Nereida Rodriguez; Hernandez, Juan Fernando Marchán; Domènech, Enric Valencia; Vernich, Carlos; de la Rosa, Sonia; Pantoja, Sebastián

    2009-01-01

    The calibration of correlation radiometers, and particularly aperture synthesis interferometric radiometers, is a critical issue to ensure their performance. Current calibration techniques are based on the measurement of the cross-correlation of receivers' outputs when injecting noise from a common noise source requiring a very stable distribution network. For large interferometric radiometers this centralized noise injection approach is very complex from the point of view of mass, volume and phase/amplitude equalization. Distributed noise injection techniques have been proposed as a feasible alternative, but are unable to correct for the so-called "baseline errors" associated with the particular pair of receivers forming the baseline. In this work it is proposed the use of centralized Pseudo-Random Noise (PRN) signals to calibrate correlation radiometers. PRNs are sequences of symbols with a long repetition period that have a flat spectrum over a bandwidth which is determined by the symbol rate. Since their spectrum resembles that of thermal noise, they can be used to calibrate correlation radiometers. At the same time, since these sequences are deterministic, new calibration schemes can be envisaged, such as the correlation of each receiver's output with a baseband local replica of the PRN sequence, as well as new distribution schemes of calibration signals. This work analyzes the general requirements and performance of using PRN sequences for the calibration of microwave correlation radiometers, and particularizes the study to a potential implementation in a large aperture synthesis radiometer using an optical distribution network.

  3. Pseudo-random Spray Release to Measure World-wide Transfer Functions of Cloud Albedo Control.

    Science.gov (United States)

    Salter, Stephen

    2010-05-01

    Institute for Energy Systems, School of Engineering, University of Edinburgh. S.Salter@ed.ac.uk Previous climate models of Latham's proposal to reverse global warming by using sub-micron sea spray to increase cloud albedo have used a variety of spray patterns. Kettles forced CCN concentration to be 375/cm3 everywhere. Rasch et al used the 20% and 70% most susceptible regions. Bala and Caldeira used an even spread. Jones et al. concentrated spray in the 3.3% oceans with the highest susceptibility All used the same rate through the year. We want to choose a scheme for a climate-modelling experiment designed to identify simultaneously the effects of cloud albedo control at various seasons of the year from spray at all regions of the world on climates of all other regions the world. In particular we want to know seasons and spray places which might have an undesirable effect on precipitation. The spray systems in various regions of a numerical climate model will be modulated on an off with different but known pseudo-random sequences and a selection of seasons. The mean value of the resulting weather records of the parameters of interest, mainly temperature and water run-off, at each region will be subtracted from each value of the record so as to give just the alternating component with an average value of zero. This will be correlated with each of the chosen pseudo-random sequences to give the magnitude and polarity of the effect of a treatment at each input area and selected seasons of the year with the resulting effects on all regions. By doing a time-shifted correlation we can account for phase-shift and time delay. The signal-to-noise ratio should improve with the square root of the analysis time and so we may be able to measure the transfer function with quite a small stimulus. The results of a Mathcad simulation of the process with statistical distributions approximating to natural variations temperature and precipitation show that a single run of a climate

  4. Synchronizing microelectrode and electronic goniometer data using a pseudo-random binary signal.

    Science.gov (United States)

    Moore, Tyler Robert; Jacobs, Rennie Underwood; Yang, Alexander Cheung; Richter, Erich Oscar

    2013-04-01

    Intra-operative investigation of the subthalamic nucleus (STN) requires concurrent measurement of microelectrode voltage, electrode depth and joint movement during deep brain stimulation (DBS) surgery. Commercial solutions to this problem exist but are more expensive. Multiple instruments from different manufacturers can collect the same data, but data from incompatible instruments are collected on disparate clocks, precluding quantitative analysis. A pseudo-random binary signal recorded simultaneously by each set of instruments allows for chronological reconciliation. A custom program collects microelectrode data while simultaneously sending a pseudo-random binary signal to instruments measuring joint movement. The record of this signal is later used to express microelectrode voltage and joint position in a single chronological frame of reference. ClockSynch was used in 15 DBS procedures. After each surgery, records of microelectrode and joint movement were successfully chronologically reconciled. In conclusion, a pseudo-random binary signal integrates disparate systems of instrumentation at a significantly decreased cost.

  5. Non-periodic pseudo-random numbers used in Monte Carlo calculations

    Science.gov (United States)

    Barberis, Gaston E.

    2007-09-01

    The generation of pseudo-random numbers is one of the interesting problems in Monte Carlo simulations, mostly because the common computer generators produce periodic numbers. We used simple pseudo-random numbers generated with the simplest chaotic system, the logistic map, with excellent results. The numbers generated in this way are non-periodic, which we demonstrated for 1013 numbers, and they are obtained in a deterministic way, which allows to repeat systematically any calculation. The Monte Carlo calculations are the ideal field to apply these numbers, and we did it for simple and more elaborated cases. Chemistry and Information Technology use this kind of simulations, and the application of this numbers to quantum Monte Carlo and cryptography is immediate. I present here the techniques to calculate, analyze and use these pseudo-random numbers, show that they lack periodicity up to 1013 numbers and that they are not correlated.

  6. Pseudo-Random Number Generators for Vector Processors and Multicore Processors

    DEFF Research Database (Denmark)

    Fog, Agner

    2015-01-01

    Large scale Monte Carlo applications need a good pseudo-random number generator capable of utilizing both the vector processing capabilities and multiprocessing capabilities of modern computers in order to get the maximum performance. The requirements for such a generator are discussed. New ways ...

  7. Stability of modulation transfer function calibration of surface profilometers using binary pseudo-random gratings and arrays with nonideal groove shapes

    Energy Technology Data Exchange (ETDEWEB)

    Barber, Samuel K.; Anderson, Erik H.; Cambie, Rossana; Marchesini, Stefano; McKinney, Wayne R.; Takacs, Peter Z.; Voronov, Dmitry L.; Yashchuk, Valeriy V.

    2010-03-31

    The major problem of measurement of a power spectral density (PSD) distribution of surface heights with surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments, which tends to distort the PSD at higher spatial frequencies. The special mathematical properties of binary pseudo-random patterns make them an ideal basis for developing MTF calibration test surfaces. Two-dimensional binary pseudo-random arrays (BPRAs) have been fabricated and used for the MTF calibration of the MicroMap{trademark}-570 interferometric microscope with all available objectives. An investigation into the effects of fabrication imperfections on the quality of the MTF calibration and a procedure for accounting for such imperfections are presented.

  8. 1.2 GBit/s Pseudo Random Pulse Generator Using Multiplexing with GaAs Mesfet Gates

    DEFF Research Database (Denmark)

    Hede, Carsten

    1978-01-01

    A l.2 Gbit/s RZ pseudo random bit generator using multiplexing of six 200 Mbit/s channels, and a GaAs-MESFET gate circuit which exhibits both high speed and simplicity are presented. As a new contribution to the treatment of pseudo random sequences it is shown how the autocorrelation function and...

  9. Information Encoding on a Pseudo Random Noise Radar Waveform

    Science.gov (United States)

    2013-03-01

    antenna under test AWG arbitrary waveform generator AWGN additive white Gaussian noise BPSK binary phase shift keying CDMA code division multiple...focused on the orthogonal frequency-division multiplexing (OFDM) and code division multiple access ( CDMA ) waveforms. The Ohio State University has...components into a single unit allows for a more mobile compact platform. The plan is diagrammed in Figure 3.5. Figure 3.5: Planned modifications to

  10. Standard environmental test methods

    Energy Technology Data Exchange (ETDEWEB)

    Schafer, D R

    1983-12-01

    This guide to uniformity in testing is intended primarily as an aid to persons responsible for designing, developing, and performing environmental tests. It will also be of use to those concerned with production, evaluation, and quality control and assurance. Checklists for preparing the environmental testing portion of product specifications are included, as are copies of Process Standards covering the instrumentation, equipment, and methods for use in environmental testing of Sandia National Laboratories components. Techniques and equipment are constantly improving. This version of SC-4452 reflects current state-of-the-art and practice in environmental testing. Previously existing sections of the document have ben updated and new ones have been added, e.g., Transient Testing on Vibration Machines.

  11. Cardiorespiratory Kinetics Determined by Pseudo-Random Binary Sequences - Comparisons between Walking and Cycling.

    Science.gov (United States)

    Koschate, J; Drescher, U; Thieschäfer, L; Heine, O; Baum, K; Hoffmann, U

    2016-12-01

    This study aims to compare cardiorespiratory kinetics as a response to a standardised work rate protocol with pseudo-random binary sequences between cycling and walking in young healthy subjects. Muscular and pulmonary oxygen uptake (V̇O2) kinetics as well as heart rate kinetics were expected to be similar for walking and cycling. Cardiac data and V̇O2 of 23 healthy young subjects were measured in response to pseudo-random binary sequences. Kinetics were assessed applying time series analysis. Higher maxima of cross-correlation functions between work rate and the respective parameter indicate faster kinetics responses. Muscular V̇O2 kinetics were estimated from heart rate and pulmonary V̇O2 using a circulatory model. Muscular (walking vs. cycling [mean±SD in arbitrary units]: 0.40±0.08 vs. 0.41±0.08) and pulmonary V̇O2 kinetics (0.35±0.06 vs. 0.35±0.06) were not different, although the time courses of the cross-correlation functions of pulmonary V̇O2 showed unexpected biphasic responses. Heart rate kinetics (0.50±0.14 vs. 0.40±0.14; P=0.017) was faster for walking. Regarding the biphasic cross-correlation functions of pulmonary V̇O2 during walking, the assessment of muscular V̇O2 kinetics via pseudo-random binary sequences requires a circulatory model to account for cardio-dynamic distortions. Faster heart rate kinetics for walking should be considered by comparing results from cycle and treadmill ergometry. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Pseudo-random Aloha for inter-frame soft combining in RFID systems

    DEFF Research Database (Denmark)

    Castiglione, Paolo; Ricciato, Fabio; Popovski, Petar

    2013-01-01

    In this work we consider a recently proposed variant of the classical Framed Slotted-ALOHA where slot selection is based on a pseudo-random function of the message to be transmitted and of the frame index. We couple this feature with convolutional encoding, that allows to perform Inter-frame Soft...... cancellation (instead of combining). Numerical simulation results show that the ISoC scheme brings a noticeable throughput gain over traditional schemes in a dense RFID scenario with multiple concurrent Tag transmissions....

  13. Pseudo-random tool paths for CNC sub-aperture polishing and other applications.

    Science.gov (United States)

    Dunn, Christina R; Walker, David D

    2008-11-10

    In this paper we first contrast classical and CNC polishing techniques in regard to the repetitiveness of the machine motions. We then present a pseudo-random tool path for use with CNC sub-aperture polishing techniques and report polishing results from equivalent random and raster tool-paths. The random tool-path used - the unicursal random tool-path - employs a random seed to generate a pattern which never crosses itself. Because of this property, this tool-path is directly compatible with dwell time maps for corrective polishing. The tool-path can be used to polish any continuous area of any boundary shape, including surfaces with interior perforations.

  14. Pseudo-random-bit-sequence phase modulation for reduced errors in a fiber optic gyroscope.

    Science.gov (United States)

    Chamoun, Jacob; Digonnet, Michel J F

    2016-12-15

    Low noise and drift in a laser-driven fiber optic gyroscope (FOG) are demonstrated by interrogating the sensor with a low-coherence laser. The laser coherence was reduced by broadening its optical spectrum using an external electro-optic phase modulator driven by either a sinusoidal or a pseudo-random bit sequence (PRBS) waveform. The noise reduction measured in a FOG driven by a modulated laser agrees with the calculations based on the broadened laser spectrum. Using PRBS modulation, the linewidth of a laser was broadened from 10 MHz to more than 10 GHz, leading to a measured FOG noise of only 0.00073  deg/√h and a drift of 0.023  deg/h. To the best of our knowledge, these are the lowest noise and drift reported in a laser-driven FOG, and this noise is below the requirement for the inertial navigation of aircraft.

  15. Covert Communication in MIMO-OFDM System Using Pseudo Random Location of Fake Subcarriers

    Directory of Open Access Journals (Sweden)

    Rizky Pratama Hudhajanto

    2016-08-01

    Full Text Available Multiple-Input Multiple-Output Orthogonal Frequency Division Multiplexing (MIMO-OFDM is the most used wireless transmission scheme in the world. However, its security is the interesting problem to discuss if we want to use this scheme to transmit a sensitive data, such as in the military and commercial communication systems. In this paper, we propose a new method to increase the security of MIMO-OFDM system using the change of location of fake subcarrier. The fake subcarriers’ location is generated per packet of data using Pseudo Random sequence generator. The simulation results show that the proposed scheme does not decrease the performance of conventional MIMO-OFDM. The attacker or eavesdropper gets worse Bit Error Rate (BER than the legal receiver compared to the conventional MIMO-OFDM system.

  16. Pseudo-Random Mating Populations. in Celebration of the 80th Anniversary of the Hardy-Weinberg Law

    OpenAIRE

    Li, C. C.

    1988-01-01

    That random mating leads to Hardy-Weinberg distribution of genotypes is well known. This report is to show that, if the deviations from random mating are of a certain pattern, the offspring generation will also be in Hardy-Weinberg proportions. This brings out the fact that random mating is a sufficient condition, not a necessary one, for the attainment of the Hardy-Weinberg proportions. Such nonrandom-mating populations are tentatively said to be pseudo-random mating. Pseudo-random-mating po...

  17. Cost-effectiveness of multidisciplinary wound care in nursing homes: a pseudo-randomized pragmatic cluster trial.

    Science.gov (United States)

    Vu, Trang; Harris, Anthony; Duncan, Gregg; Sussman, Geoff

    2007-09-01

    To evaluate the cost-effectiveness of a multidisciplinary wound care team in the nursing home setting from a health system perspective. Pseudo-randomized pragmatic cluster trial with 20-week follow-up involving 342 uncomplicated leg and pressure ulcers in 176 residents located in 44 high-care nursing homes in Melbourne, Australia in 1999-2000. Twenty-one nursing homes (180 wounds in 94 residents) were assigned to the intervention arm and 23 to the control arm (162 wounds in 82 residents). Residents in the intervention arm received standardized treatment from a wound care team comprising of trained community pharmacists and nurses. Residents in the control arm received usual care. More wounds healed during the trial in the intervention arm than in the control arm (61.7% versus 52.5%, P = 0.07). A Cox regression with shared frailty predicted that the chances of healing increased 73% for intervention wounds [95% confidence interval (CI) 20-150%, P = 0.003]. The mean treatment cost was $A616.4 for intervention and $A977.9 for control patients (P = 0.006). Most cost reduction was obtained from decreases in nursing time and waste disposal. The mean cost saving per wound, adjusted for baseline wound severity and random censoring, was $A277.9 (95% CI $A21.6-$A534.1). Standardized treatment provided by a multidisciplinary wound care team saved costs and improved chronic wound healing in nursing homes. The main source of saving was in the cost of nursing time in applying traditional dressings and in the cost of their disposal.

  18. Goal-independent mechanisms for free response generation: creative and pseudo-random performance share neural substrates.

    Science.gov (United States)

    de Manzano, Örjan; Ullén, Fredrik

    2012-01-02

    To what extent free response generation in different tasks uses common and task-specific neurocognitive processes has remained unclear. Here, we investigated overlap and differences in neural activity during musical improvisation and pseudo-random response generation. Brain activity was measured using fMRI in a group of professional classical pianists, who performed musical improvisation of melodies, pseudo-random key-presses and a baseline condition (sight-reading), on either two, six or twelve keys on a piano keyboard. The results revealed an extensive overlap in neural activity between the two generative conditions. Active regions included the dorsolateral and dorsomedial prefrontal cortices, inferior frontal gyrus, anterior cingulate cortex and pre-SMA. No regions showed higher activity in improvisation than in pseudo-random generation. These findings suggest that the activated regions fulfill generic functions that are utilized in different types of free generation tasks, independent of overall goal. In contrast, pseudo-random generation was accompanied by higher activity than improvisation in several regions. This presumably reflects the participants' musical expertise as well as the pseudo-random generation task's high load on attention, working memory, and executive control. The results highlight the significance of using naturalistic tasks to study human behavior and cognition. No brain activity was related to the size of the response set. We discuss that this may reflect that the musicians were able to use specific strategies for improvisation, by which there was no simple relationship between response set size and neural activity. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. Tests on standard concrete samples

    CERN Multimedia

    CERN PhotoLab

    1973-01-01

    Compression and tensile tests on standard concrete samples. The use of centrifugal force in tensile testing has been developed by the SB Division and the instruments were built in the Central workshops.

  20. Least squares deconvolution for leak detection with a pseudo random binary sequence excitation

    Science.gov (United States)

    Nguyen, Si Tran Nguyen; Gong, Jinzhe; Lambert, Martin F.; Zecchin, Aaron C.; Simpson, Angus R.

    2018-01-01

    Leak detection and localisation is critical for water distribution system pipelines. This paper examines the use of the time-domain impulse response function (IRF) for leak detection and localisation in a pressurised water pipeline with a pseudo random binary sequence (PRBS) signal excitation. Compared to the conventional step wave generated using a single fast operation of a valve closure, a PRBS signal offers advantageous correlation properties, in that the signal has very low autocorrelation for lags different from zero and low cross correlation with other signals including noise and other interference. These properties result in a significant improvement in the IRF signal to noise ratio (SNR), leading to more accurate leak localisation. In this paper, the estimation of the system IRF is formulated as an optimisation problem in which the l2 norm of the IRF is minimised to suppress the impact of noise and interference sources. Both numerical and experimental data are used to verify the proposed technique. The resultant estimated IRF provides not only accurate leak location estimation, but also good sensitivity to small leak sizes due to the improved SNR.

  1. Interference Suppression Performance of Automotive UWB Radars Using Pseudo Random Sequences

    Directory of Open Access Journals (Sweden)

    I. Pasya

    2015-12-01

    Full Text Available Ultra wideband (UWB automotive radars have attracted attention from the viewpoint of reducing traffic accidents. The performance of automotive radars may be degraded by interference from nearby radars using the same frequency. In this study, a scenario where two cars pass each other on a road was considered. Considering the utilization of cross-polarization, the desired-to-undesired signal power ratio (DUR was found to vary approximately from -10 to 30 dB. Different pseudo random sequences were employed for spectrum spreading the different radar signals to mitigate the interference effects. This paper evaluates the interference suppression provided by maximum length sequence (MLS and Gold sequence (GS through numerical simulations of the radar’s performance in terms of probability of false alarm and probability of detection. It was found that MLS and GS yielded nearly the same performance when the DUR is -10 dB (worst case; for example when fixing the probability of false alarm to 0.0001, the probabilities of detection were 0.964 and 0.946 respectively. The GS are more advantageous than MLS due to larger number of different sequences having the same length in GS than in MLS.

  2. Pseudo-random dynamic address configuration (PRDAC) algorithm for mobile ad hoc networks

    Science.gov (United States)

    Wu, Shaochuan; Tan, Xuezhi

    2007-11-01

    By analyzing all kinds of address configuration algorithms, this paper provides a new pseudo-random dynamic address configuration (PRDAC) algorithm for mobile ad hoc networks. Based on PRDAC, the first node that initials this network randomly chooses a nonlinear shift register that can generates an m-sequence. When another node joins this network, the initial node will act as an IP address configuration sever to compute an IP address according to this nonlinear shift register, and then allocates this address and tell the generator polynomial of this shift register to this new node. By this means, when other node joins this network, any node that has obtained an IP address can act as a server to allocate address to this new node. PRDAC can also efficiently avoid IP conflicts and deal with network partition and merge as same as prophet address (PA) allocation and dynamic configuration and distribution protocol (DCDP). Furthermore, PRDAC has less algorithm complexity, less computational complexity and more sufficient assumption than PA. In addition, PRDAC radically avoids address conflicts and maximizes the utilization rate of IP addresses. Analysis and simulation results show that PRDAC has rapid convergence, low overhead and immune from topological structures.

  3. Design of a Handheld Pseudo Random Coded UWB Radar for Human Sensing

    Directory of Open Access Journals (Sweden)

    Xia Zheng-huan

    2015-10-01

    Full Text Available This paper presents the design of a handheld pseudo random coded Ultra-WideBand (UWB radar for human sensing. The main tasks of the radar are to track the moving human object and extract the human respiratory frequency. In order to achieve perfect penetrability and good range resolution, m sequence with a carrier of 800 MHz is chosen as the transmitting signal. The modulated m-sequence can be generated directly by the high-speed DAC and FPGA to reduce the size of the radar system, and the mean power of the transmitting signal is 5 dBm. The receiver has two receiving channels based on hybrid sampling, the first receiving channel is to sample the reference signal and the second receiving channel is to obtain the radar echo. The real-time pulse compression is computed in parallel with a group of on-chip DSP48E slices in FPGA to improve the scanning rate of the radar system. Additionally, the algorithms of moving target tracking and life detection are implemented using Intel’s micro-processor, and the detection results are sent to the micro displayer fixed on the helmet. The experimental results show that the moving target located at less than 16 m far away from the wall can be tracked, and the respiratory frequency of the static human at less than 14 m far away from the wall can be extracted.

  4. Fully digital jerk-based chaotic oscillators for high throughput pseudo-random number generators up to 8.77Gbits/s

    KAUST Repository

    Mansingka, Abhinav S.

    2014-06-18

    This paper introduces fully digital implementations of four di erent systems in the 3rd order jerk-equation based chaotic family using the Euler approximation. The digitization approach enables controllable chaotic systems that reliably provide sinusoidal or chaotic output based on a selection input. New systems are introduced, derived using logical and arithmetic operations between two system implementations of different bus widths, with up to 100x higher maximum Lyapunov exponent than the original jerkequation based chaotic systems. The resulting chaotic output is shown to pass the NIST sp. 800-22 statistical test suite for pseudorandom number generators without post-processing by only eliminating the statistically defective bits. The systems are designed in Verilog HDL and experimentally verified on a Xilinx Virtex 4 FPGA for a maximum throughput of 15.59 Gbits/s for the native chaotic output and 8.77 Gbits/s for the resulting pseudo-random number generators.

  5. Design of Long Period Pseudo-Random Sequences from the Addition of m -Sequences over 𝔽 p

    Directory of Open Access Journals (Sweden)

    Ren Jian

    2004-01-01

    Full Text Available Pseudo-random sequence with good correlation property and large linear span is widely used in code division multiple access (CDMA communication systems and cryptology for reliable and secure information transmission. In this paper, sequences with long period, large complexity, balance statistics, and low cross-correlation property are constructed from the addition of m -sequences with pairwise-prime linear spans (AMPLS. Using m -sequences as building blocks, the proposed method proved to be an efficient and flexible approach to construct long period pseudo-random sequences with desirable properties from short period sequences. Applying the proposed method to 𝔽 2 , a signal set ( ( 2 n − 1 ( 2 m − 1 , ( 2 n + 1 ( 2 m + 1 , ( 2 ( n + 1 / 2 + 1 ( 2 ( m + 1 / 2 + 1 is constructed.

  6. Quasi-Coherent Noise Jamming to LFM Radar Based on Pseudo-random Sequence Phase-modulation

    Directory of Open Access Journals (Sweden)

    N. Tai

    2015-12-01

    Full Text Available A novel quasi-coherent noise jamming method is proposed against linear frequency modulation (LFM signal and pulse compression radar. Based on the structure of digital radio frequency memory (DRFM, the jamming signal is acquired by the pseudo-random sequence phase-modulation of sampled radar signal. The characteristic of jamming signal in time domain and frequency domain is analyzed in detail. Results of ambiguity function indicate that the blanket jamming effect along the range direction will be formed when jamming signal passes through the matched filter. By flexible controlling the parameters of interrupted-sampling pulse and pseudo-random sequence, different covering distances and jamming effects will be achieved. When the jamming power is equivalent, this jamming obtains higher process gain compared with non-coherent jamming. The jamming signal enhances the detection threshold and the real target avoids being detected. Simulation results and circuit engineering implementation validate that the jamming signal covers real target effectively.

  7. Pseudo-random mating populations. In celebration of the 80th anniversary of the Hardy-Weinberg law.

    Science.gov (United States)

    Li, C C

    1988-07-01

    That random mating leads to Hardy-Weinberg distribution of genotypes is well known. This report is to show that, if the deviations from random mating are of a certain pattern, the offspring generation will also be in Hardy-Weinberg proportions. This brings out the fact that random mating is a sufficient condition, not a necessary one, for the attainment of the Hardy-Weinberg proportions. Such nonrandom-mating populations are tentatively said to be pseudo-random mating. Pseudo-random-mating populations exist for both autosomal and sex-linked systems with two or multiple alleles. This report covers the basic case of a two-allele autosomal locus in detail, but the possible extension to two loci and cytonuclear systems have also been mentioned in discussion.

  8. Standard Test Method for Sandwich Corrosion Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method defines the procedure for evaluating the corrosivity of aircraft maintenance chemicals, when present between faying surfaces (sandwich) of aluminum alloys commonly used for aircraft structures. This test method is intended to be used in the qualification and approval of compounds employed in aircraft maintenance operations. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements appear in Section 9.

  9. A novel effect of Noscapine on patients with massive ischemic stroke: A pseudo-randomized clinical trial.

    Science.gov (United States)

    Mahmoudian, Massoud; Rezvani, Mohammad; Rohani, Mohammad; Benaissa, Foozya; Jalili, Mehdi; Ghourchian, Shadi

    2015-01-05

    Massive ischemic stroke causes significant mortality and morbidity in stroke patients. The main treatments for massive ischemic stroke are recombinant tissue plasminogen activator (rtPA), craniotomy, and endovascular interventions. Due to destructive effects of bradykinin on the nervous system in ischemic stroke, it seems reasonable that using Noscapine as a Bradykinin antagonist may improve patients' outcome after ischemic stroke. The effect of Noscapine on massive ischemic stroke was shown by the previous pilot study by our group. This pseudo-randomized clinical trial study was designed to assess the result of the pilot study. Patients who had clinical symptoms or computed tomography scan indicative of massive stroke (in full middle cerebral artery territory) were entered to the study. The cases received the drugs according to their turns in emergency ward (pseudo-randomized). The patient group received Noscapine, and the control group received common supportive treatments. The patients and data analyzer were blinded about the data. At the end of the study, to adjust confounding variables we used logistic regression. After 1-month follow-up, 16 patients in the control group and 11 patients in the case group expired (P = 0.193). Analyzing the data extracted from Rankin scale and Barthel index check lists, revealed no significant differences in the two groups. Despite the absence of significant statistical results in our study, the reduction rate of 16% for mortality rate in Noscapine recipients is clinically remarkable and motivates future studies with larger sample sizes.

  10. Binary pseudo-random patterned structures for modulation transfer function calibration and resolution characterization of a full-field transmission soft x-ray microscope

    Energy Technology Data Exchange (ETDEWEB)

    Yashchuk, V. V., E-mail: VVYashchuk@lbl.gov; Chan, E. R.; Lacey, I. [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Fischer, P. J. [Center for X-Ray Optics, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Physics Department, University of California Santa Cruz, Santa Cruz, California 94056 (United States); Conley, R. [Advance Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States); National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, New York 11973 (United States); McKinney, W. R. [Diablo Valley College, 321 Golf Club Road, Pleasant Hill, California 94523 (United States); Artemiev, N. A. [KLA-Tencor Corp., 1 Technology Drive, Milpitas, California 95035 (United States); Bouet, N. [National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, New York 11973 (United States); Cabrini, S. [Molecular Foundry, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Calafiore, G.; Peroz, C.; Babin, S. [aBeam Technologies, Inc., Hayward, California 94541 (United States)

    2015-12-15

    We present a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) one-dimensional sequences and two-dimensional arrays as an effective method for spectral characterization in the spatial frequency domain of a broad variety of metrology instrumentation, including interferometric microscopes, scatterometers, phase shifting Fizeau interferometers, scanning and transmission electron microscopes, and at this time, x-ray microscopes. The inherent power spectral density of BPR gratings and arrays, which has a deterministic white-noise-like character, allows a direct determination of the MTF with a uniform sensitivity over the entire spatial frequency range and field of view of an instrument. We demonstrate the MTF calibration and resolution characterization over the full field of a transmission soft x-ray microscope using a BPR multilayer (ML) test sample with 2.8 nm fundamental layer thickness. We show that beyond providing a direct measurement of the microscope’s MTF, tests with the BPRML sample can be used to fine tune the instrument’s focal distance. Our results confirm the universality of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

  11. Pseudo-random data acquisition geometry in 3D seismic survey; Sanjigen jishin tansa ni okeru giji random data shutoku reiauto ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Minegishi, M.; Tsuburaya, Y. [Japan National Oil Corp., Tokyo (Japan). Technology Research Center

    1996-10-01

    Influence of pseudo-random geometry on the imaging for 3D seismic exploration data acquisition has been investigate using a simple model by comparing with the regular geometry. When constituting wave front by the interference of elemental waves, pseudo-random geometry data did not always provide good results. In the case of a point diffractor, the imaging operation, where the constituted wave front was returned to the point diffractor by the interference of elemental waves for the spatial alias records, did not always give clear images. In the case of multi point diffractor, good images were obtained with less noise generation in spite of alias records. There are a lot of diffractors in the actual geological structures, which corresponds to the case of multi point diffractors. Finally, better images could be obtained by inputting records acquired using the pseudo-random geometry rather than by inputting spatial alias records acquired using the regular geometry. 7 refs., 6 figs.

  12. Standardization Activities in TMF Test Methodologies

    Science.gov (United States)

    Verrilli, M. J.; Castelli, M. G.; Bressers, J.; Oehmke, R. L. T.

    1996-01-01

    No standard test practice currently exists for strain-controlled thermomechanical fatigue (TMF) testing. This paper discusses recent activities which lay the foundation for standardization of TMF test methods. Specifically, the paper documents the results of two interlaboratory TMF test programs, identifies key TMF symposia and workshops, and discusses efforts toward drafting a TMF standard test practice.

  13. The "Volvo Effect"--Questioning Standardized Tests.

    Science.gov (United States)

    Wesson, Kenneth A.

    2001-01-01

    Questions current emphasis on standardized tests and discusses several factors about the tests that should prompt reevaluation of their usefulness. Issues discussed include: development and design of standardized tests; the correlation between test scores and socioeconomic position; the discrepancy between test designs and accurate reflection of…

  14. Alignment of Test with the Standards.

    Science.gov (United States)

    Romberg, Thomas A.; Wilson, Linda D.

    1992-01-01

    Examined 6 widely used grade-8 standardized tests for content, required processes, and level to determine their alignment with the 5-8 NCTM "Curriculum and Evaluation Standards." Concluded that these tests inadequately covered the 5-8 standards. A follow-up study examined items from newly developed and foreign tests to demonstrate the…

  15. Standard setting for progress tests: combining external and internal standards.

    Science.gov (United States)

    Ricketts, Chris; Freeman, Adrian C; Coombes, Lee R

    2009-06-01

    There has been little work on standard setting for progress tests and it is common practice to use normative standards. This study aimed to develop a new approach to standard setting for progress tests administered at the point when students approach graduation. In this study we obtained performance data from newly qualified doctors and used this information to set the standard for the last progress test in the final year of undergraduate medical education. This external reference was validated against projections of student performance data based upon normative grading, and other published results. A simple linear growth model was used to set pass scores for progress tests earlier in the final year and this was also validated by published data. There was good agreement between standards set using the data from newly qualified doctors, the standard expected from extrapolation of the student progression data, and published performance data from another medical school. We have demonstrated that a combination of data from independent sources can be used to triangulate standard-setting decisions for progress tests. Performance data from successive cohorts of medical students could provide a fruitful source of information for standard setting for progress tests.

  16. Analysis of heart rate and oxygen uptake kinetics studied by two different pseudo-random binary sequence work rate amplitudes.

    Science.gov (United States)

    Drescher, U; Koschate, J; Schiffer, T; Schneider, S; Hoffmann, U

    2017-06-01

    The aim of the study was to compare the kinetics responses of heart rate (HR), pulmonary (V˙O2pulm) and predicted muscular (V˙O2musc) oxygen uptake between two different pseudo-random binary sequence (PRBS) work rate (WR) amplitudes both below anaerobic threshold. Eight healthy individuals performed two PRBS WR protocols implying changes between 30W and 80W and between 30W and 110W. HR and V˙O2pulm were measured beat-to-beat and breath-by-breath, respectively. V˙O2musc was estimated applying the approach of Hoffmann et al. (Eur J Appl Physiol 113: 1745-1754, 2013) considering a circulatory model for venous return and cross-correlation functions (CCF) for the kinetics analysis. HR and V˙O2musc kinetics seem to be independent of WR intensity (p>0.05). V˙O2pulm kinetics show prominent differences in the lag of the CCF maximum (39±9s; 31±4s; pkinetics remain unchanged. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Implementing and Testing Self-Timed Rings on a FPGA as Entropy Sources

    OpenAIRE

    Einar, Marcus

    2015-01-01

    Random number generators are basic building blocks of modern cryptographic systems. Usually pseudo random number generators, carefully constructed deter- ministic algorithms that generate seemingly random numbers, are used. These are built upon foundations of thorough mathematical analysis and have been subjected to stringent testing to make sure that they can produce pseudo random sequences at a high bit-rate with good statistical properties. A pseudo random number generator must be initiate...

  18. Selecting Standardized Tests in Nursing Education.

    Science.gov (United States)

    Mee, Cheryl L; Hallenbeck, Virginia J

    2015-01-01

    Nursing faculty frequently utilize or consider the use of nationally standardized tests to evaluate nursing student performance and their potential to pass the National Council Licensure Examination (NCLEX)(©) after graduation. There is little literature available to advise and guide nursing faculty in criteria to consider when selecting a standardized testing company to assess student readiness for NCLEX. The intent of this article is to share criteria to consider when evaluating a standardized test or testing program that has been gathered through an informal survey of faculty who are currently using standardized tests. Copyright © 2012. Published by Elsevier Inc.

  19. Rock Testing Handbook (Test Standards 1993)

    Science.gov (United States)

    1993-01-01

    dimensions should be checked during machining with a micrometer or vernier caliper; final dimensions are normally measured with a micrometer and reported to...maintained at 110 ± 5 ’C. 3.8.6 Micrometer or vernier caliper for measuring length and diameter of •. test specimen. Micrometer or caliper should be direct...and normal to the long axis. Sample dimensions should be checked during machining with a micrometer or vernier caliper; final dimensions are normally

  20. Pseudo-Random Modulation of a Laser Diode for Generating Ultrasonic Longitudinal Waves

    Science.gov (United States)

    Madaras, Eric I.; Anatasi, Robert F.

    2004-01-01

    Laser generated ultrasound systems have historically been more complicated and expensive than conventional piezoelectric based systems, and this fact has relegated the acceptance of laser based systems to niche applications for which piezoelectric based systems are less suitable. Lowering system costs, while improving throughput, increasing ultrasound signal levels, and improving signal-to-noise are goals which will help increase the general acceptance of laser based ultrasound. One current limitation with conventional laser generated ultrasound is a material s damage threshold limit. Increasing the optical power to generate more signal eventually damages the material being tested due to rapid, high heating. Generation limitations for laser based ultrasound suggests the use of pulse modulation techniques as an alternate generation method. Pulse modulation techniques can spread the laser energy over time or space, thus reducing laser power densities and minimizing damage. Previous experiments by various organizations using spatial or temporal pulse modulation have been shown to generate detectable surface, plate, and bulk ultrasonic waves with narrow frequency bandwidths . Using narrow frequency bandwidths improved signal detectability, but required the use of expensive and powerful lasers and opto-electronic systems. The use of a laser diode to generate ultrasound is attractive because of its low cost, small size, light weight, simple optics and modulation capability. The use of pulse compression techniques should allow certain types of laser diodes to produce usable ultrasonic signals. The method also does not need to be limited to narrow frequency bandwidths. The method demonstrated here uses a low power laser diode (approximately 150 mW) that is modulated by controlling the diode s drive current and the resulting signal is recovered by cross correlation. A potential application for this system which is briefly demonstrated is in detecting signals in thick

  1. On Standardized Testing: An ACEI Position Paper

    Science.gov (United States)

    Solley, Bobbie A.

    2007-01-01

    Following the whirlwind standards movement of the 1980s, the beginning of the 1990s ushered in an overwhelming interest in and use of testing to document students' progress. In 1991, the Association for Childhood Education International (ACEI) issued its second position paper calling for a moratorium on standardized testing in the early years of…

  2. Standardized Testing: Measurement of Academic Achievement

    Science.gov (United States)

    Weaver, Keshia

    2011-01-01

    Standardized testing has been a very important issue in education today. Many schools use the testing score to determine whether a child should continue to the next grade level. As we review the methods teachers use to prepare students for these types of tests, the amount of instruction time utilized to cover test materials, and the level of…

  3. Standards for educational and psychological testing

    CERN Document Server

    2014-01-01

    Developed jointly by the American Educational Research Association, American Psychological Association, and the National Council on Measurement in Education, Standards for Educational and Psychological Testing (Revised 2014) addresses professional and technical issues of test development and use in education, psychology, and employment. It includes changes in federal law and measurement trends affecting validity, testing individuals with disabilities or different linguistic backgrounds, and new types of tests, as well as new uses of existing tests.

  4. Standardized Testing in Alabama and Nationwide. Updated

    Science.gov (United States)

    Rains, Thomas

    2014-01-01

    Standardized testing serves several purposes. Tests provide feedback on a student's performance. They can help teachers understand student achievement relative to class objectives. Tests can also help administrators identify excellent teachers and those who need more professional support. And, likewise, they can help administrators and…

  5. 76 FR 74078 - Standard Mail Market Test

    Science.gov (United States)

    2011-11-30

    ... Standard Mail Market Test AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: The Commission is... that applies to market tests of experimental market dominant products. It seeks the exemption for Every... exemption from the $10,000,000 revenue limitation in any year during the test of an experimental market...

  6. Neutron Sources for Standard-Based Testing

    Energy Technology Data Exchange (ETDEWEB)

    Radev, Radoslav [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); McLean, Thomas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-11-10

    The DHS TC Standards and the consensus ANSI Standards use 252Cf as the neutron source for performance testing because its energy spectrum is similar to the 235U and 239Pu fission sources used in nuclear weapons. An emission rate of 20,000 ± 20% neutrons per second is used for testing of the radiological requirements both in the ANSI standards and the TCS. Determination of the accurate neutron emission rate of the test source is important for maintaining consistency and agreement between testing results obtained at different testing facilities. Several characteristics in the manufacture and the decay of the source need to be understood and accounted for in order to make an accurate measurement of the performance of the neutron detection instrument. Additionally, neutron response characteristics of the particular instrument need to be known and taken into account as well as neutron scattering in the testing environment.

  7. American History's Problem with Standardized Testing

    Science.gov (United States)

    McCoog, Ian J.

    2005-01-01

    This article looks at current research concerning how students best learn the discipline of history, commentaries both in favor of and against standardized testing, and basic philosophical beliefs about the discipline. It explains methods of how to incorporate differentiated lessons and performance based assessments to NCLB standards and…

  8. Standardized Definitions for Code Verification Test Problems

    Energy Technology Data Exchange (ETDEWEB)

    Doebling, Scott William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-14

    This document contains standardized definitions for several commonly used code verification test problems. These definitions are intended to contain sufficient information to set up the test problem in a computational physics code. These definitions are intended to be used in conjunction with exact solutions to these problems generated using Exact- Pack, www.github.com/lanl/exactpack.

  9. Comparison of tool feed influence in CNC polishing between a novel circular-random path and other pseudo-random paths.

    Science.gov (United States)

    Takizawa, Ken; Beaucamp, Anthony

    2017-09-18

    A new category of circular pseudo-random paths is proposed in order to suppress repetitive patterns and improve surface waviness on ultra-precision polished surfaces. Random paths in prior research had many corners, therefore deceleration of the polishing tool affected the surface waviness. The new random path can suppress velocity changes of the polishing tool and thus restrict degradation of the surface waviness, making it suitable for applications with stringent mid-spatial-frequency requirements such as photomask blanks for EUV lithography.

  10. Which Test? Whose Scores? Comparing Standardized Critical Thinking Tests

    Science.gov (United States)

    Hatcher, Donald L.

    2011-01-01

    In this article, after describing one approach for teaching critical thinking (CT) that was in place at Baker University from 1990 to 2008, the author describes their experience assessing CT using three standardized exams and shows why the choice of a standardized CT test can be problematic and the results misleading. These results can be…

  11. Taking tests in the magnet: Brain mapping standardized tests.

    Science.gov (United States)

    Rubin, David C; Li, Dawei; Hall, Shana A; Kragel, Philip A; Berntsen, Dorthe

    2017-11-01

    Standardized psychometric tests are sophisticated, well-developed, and consequential instruments; test outcomes are taken as facts about people that impact their lives in important ways. As part of an initial demonstration that human brain mapping techniques can add converging neural-level evidence to understanding standardized tests, our participants completed items from standardized tests during an fMRI scan. We compared tests for diagnosing posttraumatic stress disorder (PTSD) and the correlated measures of Neuroticism, Attachment, and Centrality of Event to a general-knowledge baseline test. Twenty-three trauma-exposed participants answered 20 items for each of our five tests in each of the three runs for a total of 60 items per test. The tests engaged different neural processes; which test a participant was taking was accurately predicted from other participants' brain activity. The novelty of the application precluded specific anatomical predictions; however, the interpretation of activated regions using meta-analyses produced encouraging results. For instance, items on the Attachment test engaged regions shown to be more active for tasks involving judgments of others than judgments of the self. The results are an initial demonstration of a theoretically and practically important test-taking neuroimaging paradigm and suggest specific neural processes in answering PTSD-related tests. Hum Brain Mapp 38:5706-5725, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  12. The skin prick test – European standards

    Science.gov (United States)

    2013-01-01

    Skin prick testing is an essential test procedure to confirm sensitization in IgE-mediated allergic disease in subjects with rhinoconjunctivitis, asthma, urticaria, anapylaxis, atopic eczema and food and drug allergy. This manuscript reviews the available evidence including Medline and Embase searches, abstracts of international allergy meetings and position papers from the world allergy literature. The recommended method of prick testing includes the appropriate use of specific allergen extracts, positive and negative controls, interpretation of the tests after 15 – 20 minutes of application, with a positive result defined as a wheal ≥3 mm diameter. A standard prick test panel for Europe for inhalants is proposed and includes hazel (Corylus avellana), alder (Alnus incana), birch (Betula alba), plane (Platanus vulgaris), cypress (Cupressus sempervirens), grass mix (Poa pratensis, Dactilis glomerata, Lolium perenne, Phleum pratense, Festuca pratensis, Helictotrichon pretense), Olive (Olea europaea), mugwort (Artemisia vulgaris), ragweed (Ambrosia artemisiifolia), Alternaria alternata (tenuis), Cladosporium herbarum, Aspergillus fumigatus, Parietaria, cat, dog, Dermatophagoides pteronyssinus, Dermatophagoides farinae, and cockroach (Blatella germanica). Standardization of the skin test procedures and standard panels for different geographic locations are encouraged worldwide to permit better comparisons for diagnostic, clinical and research purposes. PMID:23369181

  13. The skin prick test – European standards

    Directory of Open Access Journals (Sweden)

    Heinzerling Lucie

    2013-02-01

    Full Text Available Abstract Skin prick testing is an essential test procedure to confirm sensitization in IgE-mediated allergic disease in subjects with rhinoconjunctivitis, asthma, urticaria, anapylaxis, atopic eczema and food and drug allergy. This manuscript reviews the available evidence including Medline and Embase searches, abstracts of international allergy meetings and position papers from the world allergy literature. The recommended method of prick testing includes the appropriate use of specific allergen extracts, positive and negative controls, interpretation of the tests after 15 – 20 minutes of application, with a positive result defined as a wheal ≥3 mm diameter. A standard prick test panel for Europe for inhalants is proposed and includes hazel (Corylus avellana, alder (Alnus incana, birch (Betula alba, plane (Platanus vulgaris, cypress (Cupressus sempervirens, grass mix (Poa pratensis, Dactilis glomerata, Lolium perenne, Phleum pratense, Festuca pratensis, Helictotrichon pretense, Olive (Olea europaea, mugwort (Artemisia vulgaris, ragweed (Ambrosia artemisiifolia, Alternaria alternata (tenuis, Cladosporium herbarum, Aspergillus fumigatus, Parietaria, cat, dog, Dermatophagoides pteronyssinus, Dermatophagoides farinae, and cockroach (Blatella germanica. Standardization of the skin test procedures and standard panels for different geographic locations are encouraged worldwide to permit better comparisons for diagnostic, clinical and research purposes.

  14. Standardized Testing: How Prepared Are We?

    Science.gov (United States)

    Smolin, Andrea; Clayton, Jennifer K.

    2009-01-01

    This case exemplifies the effects of high stakes standardized testing and accountability on education and stakeholders. When schools are pressured for success, educational leaders and teachers often find themselves in circumstances where regulations and procedures are violated, sometimes with noble intent. The case focuses on the ethical and…

  15. Four Tips for Surviving Standardized Testing

    Science.gov (United States)

    Martin, Anna

    2012-01-01

    As the tenth anniversary of NCLB has come and gone, both new and experienced educators continue to wrestle yearly with the standardized testing culture that has pervaded the educational experience of nearly every American child and teacher. Despite the requests for waivers to exempt certain states from NCLB, the majority of students and their…

  16. A standard test for filter media cleanliness

    African Journals Online (AJOL)

    driniev

    2004-01-01

    Jan 1, 2004 ... 81. Available on website http://www.wrc.org.za. A standard test for filter media cleanliness. SJ van Staden and J Haarhoff*. RAU Water Research Group, PO Box 524, Auckland Park 2006, South Africa. Abstract. Rapid sand filters are expected to produce clean, safe water, without interruption, for many years.

  17. (De)Grading the Standardized Test: Can Standardized Testing Evaluate Schools?

    Science.gov (United States)

    Simmons, Nicola E.

    2004-01-01

    Standardized testing is an assessment strategy that evaluates all students and all schools on the same basic skills and, therefore, might reasonably indicate which schools are high performers and which are not. Standardized testing is not a new strategy for providing this proof. The United States has produced reams of articles criticizing…

  18. Standard specification for agencies performing nondestructive testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This specification covers minimum requirements for agencies performing nondestructive testing (NDT). 1.2 When using this specification to assess the capability of, or to accredit NDT agencies, Guide E 1359 shall be used as a basis for the survey. It can be supplemented as necessary with more detail in order to meet the auditor's specific needs. 1.3 This specification can be used as a basis to evaluate testing or inspection agencies, or both, and is intended for use for the qualifying or accrediting, or both, of testing or inspection agencies, public or private. 1.4 The use of SI or inch-pound units, or combination thereof, will be the responsibility of the technical committee whose standards are referred to in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to...

  19. Patch testing with Indian standard series

    Directory of Open Access Journals (Sweden)

    Narendra G

    2002-01-01

    Full Text Available Hundred patients (61 males, 39 females suspected to have allergic contact dermatitis were patch tested with Indian standard series (ISS. Forty four showed one or more positive reactions. The frequent sensitizers observed were nickel sulphate-12 (15%, potassium dichromate-11 (13.75%, cobalt chloride and colophony-7 (8.75% each, fragrance mix and thiuram mix-6 (7.5% each. The ISS differs from the European Standard Series by inclusion of propylene glycol, nitrofurazone, gentamicin, chlorocresol, PEG-400 and ethylenediamine chloride where assesquiterpene lactone mix and primin allergens are excluded.

  20. Standard Penetration Test and Relative Density

    Science.gov (United States)

    1971-02-01

    La Prueba Normal de Penetraciocn y la Densidad Relativa K.-J. Melzer PhD, Research Engineer U. S. Army Engineer Waterways Experiment Station Vicksburg...en la prueba normal de penetraci’n (Standard Penetration Test) de una arena bajo el nivel freatico y el correspond- iente numero en una arena seca (ie...de laboratorio ejecutados con un penetr6metro est’tico pequeno. INTRODUCTION One of the main problems encountered in subsoil e’xploration is in situ

  1. OLAF: standardization of international olfactory tests.

    Science.gov (United States)

    Hummel, C; Zucco, G M; Iannilli, E; Maboshe, W; Landis, B N; Hummel, T

    2012-03-01

    Developed in the 1990 s, the "Sniffin 'Sticks" test for the assessment of olfactory threshold, odor identification and discrimination has become a widely used tool both in clinical and research settings. Originally pencil-and-paper documented, it may now be applied using a computer program. The "Filemaker" based software "OLAF" guides the examiner through any user-defined arrangement of the test battery, stores all data in a database, and offers results sheets to be printed out for convenience. The royalty-free program may be downloaded from http://www.tu-dresden.de/medkhno/riechen_schmecken/olaf.zip as a runtime solution application. It is currently available in four languages (English, French, German, and Italian) which can be toggled by a single mouse click, and is suitable for Windows as well as Apple platforms. In conclusion, the currently described software is expected to further facilitate and standardize olfactory testing with the "Sniffin' Sticks" test battery.

  2. Experimentally testing the standard cosmological model

    Energy Technology Data Exchange (ETDEWEB)

    Schramm, D.N. (Chicago Univ., IL (USA) Fermi National Accelerator Lab., Batavia, IL (USA))

    1990-11-01

    The standard model of cosmology, the big bang, is now being tested and confirmed to remarkable accuracy. Recent high precision measurements relate to the microwave background; and big bang nucleosynthesis. This paper focuses on the latter since that relates more directly to high energy experiments. In particular, the recent LEP (and SLC) results on the number of neutrinos are discussed as a positive laboratory test of the standard cosmology scenario. Discussion is presented on the improved light element observational data as well as the improved neutron lifetime data. alternate nucleosynthesis scenarios of decaying matter or of quark-hadron induced inhomogeneities are discussed. It is shown that when these scenarios are made to fit the observed abundances accurately, the resulting conclusions on the baryonic density relative to the critical density, {Omega}{sub b}, remain approximately the same as in the standard homogeneous case, thus, adding to the robustness of the standard model conclusion that {Omega}{sub b} {approximately} 0.06. This latter point is the deriving force behind the need for non-baryonic dark matter (assuming {Omega}{sub total} = 1) and the need for dark baryonic matter, since {Omega}{sub visible} < {Omega}{sub b}. Recent accelerator constraints on non-baryonic matter are discussed, showing that any massive cold dark matter candidate must now have a mass M{sub x} {approx gt} 20 GeV and an interaction weaker than the Z{sup 0} coupling to a neutrino. It is also noted that recent hints regarding the solar neutrino experiments coupled with the see-saw model for {nu}-masses may imply that the {nu}{sub {tau}} is a good hot dark matter candidate. 73 refs., 5 figs.

  3. Toward standardization of EAP actuators test procedures

    Science.gov (United States)

    Fernandez, Diego; Moreno, Luis; Baselga, Juan

    2005-05-01

    Since the field of Electroactive Polymers (EAP) actuators is fairly new there are no standard testing processes for such intelligent materials. This drawback can seriously limit the scope of application of EAP actuators, since the targeted industrial sectors (aerospace, biomedical...) demand high reliability and product assurance. As a first iteration two elements are required to define a test standard for an EAP actuator: a Unit Tester, and a Component Specification. In this paper a EAP Unit Tester architecture is presented along with the required classification of measurements to be included in the EAP actuator Component Specification. The proposed EAP Unit Tester allows on-line monitoring and recording of the following properties of the specimen under test: large deformation, small tip displacement, temperature at the electrodes, weight of the specimen, voltage and current driven into the EAP, load being applied to the actuator, output voltage of the EAP in sensing operation and mode of operation (structure/sensor/actuator/smart). The measurements are taken simultaneously, in real-time. The EAP Unit Tester includes a friendly Graphical User Interface. It uses embedded Excel tools to visualize data. In addition, real-time connectivity with MATLAB allows an easy testing of control algorithms. A novel methodology to measure the properties of EAP specimens versus a variable load is also presented. To this purpose a force signals generator in the range of mN was developed. The device is based on a DC mini-motor. It generates an opposing force to the movement of the EAP actuator. Since the device constantly opposes the EAP actuator movement it has been named Digital Force Generator (DFG). The DFG design allows simultaneous length and velocity measuring versus different load signals. By including such a device in the EAP Unit Tester the most suitable application for the specimen under test can be easily identified (vibration damper, large deformation actuator, large

  4. Multipurpose laboratory test system applying CAMAC standards

    Energy Technology Data Exchange (ETDEWEB)

    Bowers, J.L.

    1976-11-01

    A flexible electronic product test and evaluation system is proposed. A system study was performed to determine how increasingly complex telemetry systems could be effectively evaluated during development and preproduction and after first production units were built. A primary requirement was that this system remain flexible with respect to configuration and mission and that it be easily maintainable. In addition, the system must be upgraded easily as old product requirements and definitions are replaced by new designs. As a result of this study it is concluded that this project would involve the expenditure of considerable funds and manpower at the beginning of the project and that the cost effectiveness of the system would be dependent upon its utilization and management. This study also demonstrates how the use of computer interface hardware standards (IEEE 583) can minimize requirements for expensive specially designed test equipment for each application.

  5. Standard-E hydrogen monitoring system shop acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, T.C.

    1997-10-02

    The purpose of this report is to document that the Standard-E Hydrogen Monitoring Systems (SHMS-E), fabricated by Mid-Columbia Engineering (MCE) for installation on the Waste Tank Farms in the Hanford 200 Areas, are constructed as intended by the design. The ATP performance will verify proper system fabrication.

  6. Standard practice for instrumented indentation testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This practice defines the basic steps of Instrumented Indentation Testing (IIT) and establishes the requirements, accuracies, and capabilities needed by an instrument to successfully perform the test and produce the data that can be used for the determination of indentation hardness and other material characteristics. IIT is a mechanical test that measures the response of a material to the imposed stress and strain of a shaped indenter by forcing the indenter into a material and monitoring the force on, and displacement of, the indenter as a function of time during the full loading-unloading test cycle. 1.2 The operational features of an IIT instrument, as well as requirements for Instrument Verification Annex A1), Standardized Reference Blocks (Annex A2) and Indenter Requirements (Annex A3) are defined. This practice is not intended to be a complete purchase specification for an IIT instrument. 1.3 With the exception of the non-mandatory Appendix X4, this practice does not define the analysis necessary...

  7. 8 CFR 312.3 - Standardized citizenship testing.

    Science.gov (United States)

    2010-01-01

    ... 8 Aliens and Nationality 1 2010-01-01 2010-01-01 false Standardized citizenship testing. 312.3... REQUIREMENTS FOR NATURALIZATION § 312.3 Standardized citizenship testing. (a)(1) An applicant for... from the testing entity concerning the applicant's test. (4) An applicant who has failed a standardized...

  8. IEC 61850 Industrial Communication Standards under Test

    CERN Document Server

    Tilaro, F M; Gonzalez-Berges, M

    2014-01-01

    IEC-61850, as part of the International Electrotechnical Commission's (IEC) Technical Committee 57 (TC57), defines an international and standardized methodology to design electric power automation substations.

  9. Commercial Pilot Practical Test Standards for Rotorcraft, Helicopter, Gyroplane

    Science.gov (United States)

    1996-04-01

    The Commercial Pilot Rotorcraft (Helicopter and Gyroplane) Practical Test : Standards (PTS) book has been published by the Federal Aviation : Administration (FAA) to establish the standards for commercial pilot certification : practical tests for the...

  10. Interpreting Results from the Standardized UXO Test Sites

    National Research Council Canada - National Science Library

    May, Michael; Tuley, Michael

    2007-01-01

    ...) and the Environmental Security Technology Certification Program (ESCTP) to complete a detailed analysis of the results of testing carried out at the Standardized Unexploded Ordnance (UXO) Test Sites...

  11. Standardized Testing and the Construction of Governable Persons

    Science.gov (United States)

    Graham, Cameron; Neu, Dean

    2004-01-01

    While debates over standardized testing are ubiquitous, there has been relatively little consideration of how today's standardized testing practices have arisen. The current study provides a chronology of standardized testing within Alberta, Canada. Starting from prior work by Foucault and others on "governmentality", we propose that the…

  12. Standardization of Test for Assessment and Comparing of Students' Measurement

    Science.gov (United States)

    Osadebe, Patrick U.

    2014-01-01

    The study Standardized Economics Achievement Test for senior secondary school students in Nigeria. Three research questions guided the study. The standardized test in Economics was first constructed by an expert as a valid and reliable instrument. The test was then used for standardization in this study. That is, ensuring that the Economics…

  13. On the short-term predictability of fully digital chaotic oscillators for pseudo-random number generation

    KAUST Repository

    Radwan, Ahmed Gomaa

    2014-06-18

    This paper presents a digital implementation of a 3rd order chaotic system using the Euler approximation. Short-term predictability is studied in relation to system precision, Euler step size and attractor size and optimal parameters for maximum performance are derived. Defective bits from the native chaotic output are neglected and the remaining pass the NIST SP. 800-22 tests without post-processing. The resulting optimized pseudorandom number generator has throughput up to 17.60 Gbits/s for a 64-bit design experimentally verified on a Xilinx Virtex 4 FPGA with logic utilization less than 1.85%.

  14. Standard Guide for Testing Polymer Matrix Composite Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This guide summarizes the application of ASTM standard test methods (and other supporting standards) to continuous-fiber reinforced polymer matrix composite materials. The most commonly used or most applicable ASTM standards are included, emphasizing use of standards of Committee D30 on Composite Materials. 1.2 This guide does not cover all possible standards that could apply to polymer matrix composites and restricts discussion to the documented scope. Commonly used but non-standard industry extensions of test method scopes, such as application of static test methods to fatigue testing, are not discussed. A more complete summary of general composite testing standards, including non-ASTM test methods, is included in the Composite Materials Handbook (MIL-HDBK-17). Additional specific recommendations for testing textile (fabric, braided) composites are contained in Guide D6856. 1.3 This guide does not specify a system of measurement; the systems specified within each of the referenced standards shall appl...

  15. Fully digital 1-D, 2-D and 3-D multiscroll chaos as hardware pseudo random number generators

    KAUST Repository

    Mansingka, Abhinav S.

    2012-10-07

    This paper introduces the first fully digital implementation of 1-D, 2-D and 3-D multiscroll chaos using the sawtooth nonlinearity in a 3rd order ODE with the Euler approximation. Systems indicate chaotic behaviour through phase space boundedness and positive Lyapunov exponent. Low-significance bits form a PRNG and pass all tests in the NIST SP. 800-22 suite without post-processing. Real-time control of the number of scrolls allows distinct output streams with 2-D and 3-D multiscroll chaos enabling greater controllability. The proposed PRNGs are experimentally verified on a Xilinx Virtex 4 FPGA with logic utilization less than 1.25%, throughput up to 5.25 Gbits/s and up to 512 distinct output streams with low cross-correlation.

  16. An Instrument to Assess Beliefs about Standardized Testing: Measuring the Influence of Epistemology on the Endorsement of Standardized Testing

    Science.gov (United States)

    Magee, Robert G.; Jones, Brett D.

    2012-01-01

    This article describes the development of an instrument to assess beliefs about standardized testing in schools, a topic of much heated debate. The Beliefs About Standardized Testing scale was developed to measure the extent to which individuals support high-stakes standardized testing. The 9-item scale comprises three subscales which measure…

  17. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  18. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  19. Precision tests of the standard electroweak model

    CERN Document Server

    1995-01-01

    High precision measurements of weak neutral current and charged current processes and of the properties of the Z and W bosons have established the standard electroweak model as correct down to a distance scale of 10-16 cm, and are a sensitive probe of possible underlying physics. In this book, all aspects of the program are considered in detail, including the structure of the standard model, radiative corrections, high precision experiments, and their implications. The major classes of experiments are surveyed, covering the experiments themselves, the data analysis, results, and prospects. Thi

  20. Test System for Standard ALICE DCS Components

    CERN Document Server

    AUTHOR|(CDS)2160773

    2016-01-01

    Currently, the ALICE DCS project is supervising equipment installed in the ALICE experiment site at CERN. Hence, the aim of this project was to provide a test bench in the DCS lab, where a real equipment and software tools will be deployed. Using this test bench, test procedures which exercise the devices under the test in a configurable way and provide logging and trending of the acquired data were implemented. The setup was devised using the ALICE software framework and Siemens SCADA system WINCC OA, providing the same functionality as the systems installed in ALICE, and will be used for the commissioning of the new software and hardware, burn-in tests of new modules and log-term stability tests of ALICE hardware.

  1. The skin prick test - European standards

    NARCIS (Netherlands)

    Heinzerling, Lucie; Mari, Adriano; Bergmann, Karl-Christian; Bresciani, Megon; Burbach, Guido; Darsow, Ulf; Durham, Stephen; Fokkens, Wytske; Gjomarkaj, Mark; Haahtela, Tari; Bom, Ana Todo; Wöhrl, Stefan; Maibach, Howard; Lockey, Richard

    2013-01-01

    Skin prick testing is an essential test procedure to confirm sensitization in IgE-mediated allergic disease in subjects with rhinoconjunctivitis, asthma, urticaria, anapylaxis, atopic eczema and food and drug allergy. This manuscript reviews the available evidence including Medline and Embase

  2. How I Learned to Stop Worrying and Love Standardized Testing

    Science.gov (United States)

    Moxey, Tim

    2005-01-01

    The benefits of standardized testing for a teacher are mentioned for which the teacher has to prepare for the students only for the test and not worry for preparing the students for college, work and life. Standardized testing takes away individualized instruction, does not allow creativity, does not measure true progress or advance critical…

  3. SEDIMENT TOXICITY ASSESSMENT: COMPARISON OF STANDARD AND NEW TESTING DESIGNS

    Science.gov (United States)

    Standard methods of sediment toxicity testing are fairly well accepted; however, as with all else, evolution of these methods is inevitable. We compared a standard ASTM 10-day amphipod toxicity testing method with smaller, 48- and 96-h test methods using very toxic and reference ...

  4. Learner Washback Variability in Standardized Exit Tests

    Science.gov (United States)

    Pan, Yi-Ching

    2014-01-01

    In much of the world, the issue of accountability and measurement of educational outcomes is highly controversial. Exit testing is part of the movement to ascertain what students have learned and hold institutions and teachers to account. However, compared to the large number of teacher washback studies, learner washback research is lacking…

  5. Standard guide for fretting fatigue testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide defines terminology and covers general requirements for conducting fretting fatigue tests and reporting the results. It describes the general types of fretting fatigue tests and provides some suggestions on developing and conducting fretting fatigue test programs. 1.2 Fretting fatigue tests are designed to determine the effects of mechanical and environmental parameters on the fretting fatigue behavior of metallic materials. This guide is not intended to establish preference of one apparatus or specimen design over others, but will establish guidelines for adherence in the design, calibration, and use of fretting fatigue apparatus and recommend the means to collect, record, and reporting of the data. 1.3 The number of cycles to form a fretting fatigue crack is dependent on both the material of the fatigue specimen and fretting pad, the geometry of contact between the two, and the method by which the loading and displacement are imposed. Similar to wear behavior of materials, it is important t...

  6. Towards a standardization of biomethane potential tests

    DEFF Research Database (Denmark)

    Holliger, C.; Alves, M.; Andrade, D.

    2016-01-01

    Production of biogas fromdifferent organic materials is a most interesting source of renewable energy. The biomethane potential (BMP) of these materials has to be determined to get insight in design parameters for anaerobic digesters. Although several norms and guidelines for BMP tests exist...

  7. HISTORY AND EVOLUTION OF STANDARDIZED TESTING – A LITERATURE REVIEW

    OpenAIRE

    Dr. Syeda Rakhshanda Kaukab; Syeda Mehrunnisa

    2017-01-01

    This paper has been written with the intent of providing the history and evolution of the modern standardized testing while also highlighting the importance, pros and cons of standardized testing. In Pakistan, recently the higher education institution has established institute for development and implementation of standardized testing for admissions to the universities. It is for the first time that this is being introduced. Therefore, it appears in order that first the global development and...

  8. Historical Evolution of NASA Standard Materials Testing with Hypergolic Propellants and Ammonia (NASA Standard 6001 Test 15)

    Science.gov (United States)

    Greene, Benjamin; McClure, Mark B.

    2012-01-01

    The NASA Johnson Space Center White Sands Test Facility (WSTF) has performed testing of hazardous and reactive aerospace fluids, including hypergolic propellants, with materials since the 1960s with the Apollo program. Amongst other test activities, Test 15 is a NASA standard test for evaluating the reactivity of materials with selected aerospace fluids, in particular hydrazine, monomethylhydrazine, uns-dimethylhydrazine, Aerozine 50, dinitrogen tetroxide oxidizers, and ammonia. This manuscript provides an overview of the history of Test 15 over a timeline ranging from prior to its development and first implementation as a NASA standard test in 1974 to its current refinement. Precursor documents to NASA standard tests, as they are currently known, are reviewed. A related supplementary test, international standardization, and enhancements to Test 15 are also discussed. Because WSTF was instrumental in the development and implementation of Test 15, WSTF experience and practices are referred to in this manuscript.

  9. Standard test method for creep-fatigue testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of mechanical properties pertaining to creep-fatigue deformation or crack formation in nominally homogeneous materials, or both by the use of test specimens subjected to uniaxial forces under isothermal conditions. It concerns fatigue testing at strain rates or with cycles involving sufficiently long hold times to be responsible for the cyclic deformation response and cycles to crack formation to be affected by creep (and oxidation). It is intended as a test method for fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. The cyclic conditions responsible for creep-fatigue deformation and cracking vary with material and with temperature for a given material. 1.2 The use of this test method is limited to specimens and does not cover testing of full-scale components, structures, or consumer products. 1.3 This test method is primarily ...

  10. Standard Test Method for Testing Nonmetallic Seal Materials by Immersion in a Simulated Geothermal Test Fluid

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This test method covers a procedure for a laboratory test for performing an initial evaluation (screening) of nonmetallic seal materials by immersion in a simulated geothermal test fluid. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 6 and 11.7.

  11. Student evaluation of a standardized comprehensive testing program.

    Science.gov (United States)

    Richards, Elizabeth A; Stone, Cynthia L

    2008-01-01

    Computer-based, standardized, comprehensive testing is becoming a popular assessment tool in nursing education.This study sought to determine student response and satisfaction regarding such testing at a large state nursing school. Surveys that reviewed the entire testing process were provided to all students taking the computerized testing. Student feedback led to revisions for future testing.

  12. A Comparative Study on Automotive Brake Testing Standards

    Science.gov (United States)

    Kumbhar, Bhau Kashinath; Patil, Satyajit Ramchandra; Sawant, Suresh Maruti

    2017-08-01

    Performance testing of automotive brakes involves determination of stopping time, distance and deceleration level. Braking performance of an automobile is required to be ensured for various surfaces like dry, wet, concrete, bitumen etc. as well as for prolonged applications. Various brake testing standards are used worldwide to assure vehicle and pedestrian safety. This article presents methodologies used for automotive service brake testing for two wheelers. The main contribution of this work lies in comparative study of three main brake testing standards; viz. Indian Standards, Federal Motor Vehicle Safety Standards and European Economic Commission Standards. This study shall help the policy makers to choose the best criteria out of these three while formulating newer edition of testing standards.

  13. DOE standard: Quality assurance inspection and testing of HEPA filters

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-02-01

    This standard establishes essential elements for the quality assurance inspection and testing of HEPA filters by US Department of Energy (DOE)-accepted Filter Test Facilities (FTF). The standard specifies HEPA filter quality assurance inspection and testing practices established in DOE-STD-3022-98, DOE HEPA Filter Test Program, and provides a basis for the preparation of written operating procedures for primary FTF functions.

  14. A Measure of Failure: The Political Origins of Standardized Testing

    Science.gov (United States)

    Garrison, Mark J.

    2009-01-01

    How did standardized tests become the measure of performance in our public schools? In this compelling work, Mark J. Garrison attempts to answer this question by analyzing the development of standardized testing, from the days of Horace Mann and Alfred Binet to the current scene. Approaching the issue from a sociohistorical perspective, the author…

  15. Preparing Students for Critical-Thinking Applications on Standardized Tests

    Science.gov (United States)

    Hendricks, Jacquelyn Kaye

    2010-01-01

    Student performance on critical-thinking applications on standardized tests in a southwestern U.S. state has been low for several years. The purpose of this instrumental case study was to explore how one school district prepared students for critical-thinking applications on standardized tests. The study was informed by cognitivism and…

  16. A standard for test reliability in group research

    NARCIS (Netherlands)

    Ellis, J.L.

    2013-01-01

    Many authors adhere to the rule that test reliabilities should be at least .70 or .80 in group research. This article introduces a new standard according to which reliabilities can be evaluated. This standard is based on the costs or time of the experiment and of administering the test. For example,

  17. Issues in Standardizing Psychometric Tests for Children Who Are Blind.

    Science.gov (United States)

    Hull, T.; Mason, H.

    1993-01-01

    This article discusses issues and difficulties encountered in efforts at the University of Birmingham (England) to standardize a new psychometric assessment tool, a tactile speed-of-information-processing test for children with blindness. The problem of defining the population on which the test is standardized is seen as particularly difficult.…

  18. Hearing Aid–Related Standards and Test Systems

    Science.gov (United States)

    Ravn, Gert; Preves, David

    2015-01-01

    Many documents describe standardized methods and standard equipment requirements in the field of audiology and hearing aids. These standards will ensure a uniform level and a high quality of both the methods and equipment used in audiological work. The standards create the basis for measuring performance in a reproducible manner and independent from how and when and by whom parameters have been measured. This article explains, and focuses on, relevant acoustic and electromagnetic compatibility parameters and describes several test systems available. PMID:27516709

  19. Standard test method for creep-fatigue crack growth testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of creep-fatigue crack growth properties of nominally homogeneous materials by use of pre-cracked compact type, C(T), test specimens subjected to uniaxial cyclic forces. It concerns fatigue cycling with sufficiently long loading/unloading rates or hold-times, or both, to cause creep deformation at the crack tip and the creep deformation be responsible for enhanced crack growth per loading cycle. It is intended as a guide for creep-fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. Therefore, this method requires testing of at least two specimens that yield overlapping crack growth rate data. The cyclic conditions responsible for creep-fatigue deformation and enhanced crack growth vary with material and with temperature for a given material. The effects of environment such as time-dependent oxidation in enhancing the crack growth ra...

  20. Standard guide for conducting exfoliation corrosion tests in aluminum alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1992-01-01

    1.1 This guide differs from the usual ASTM standard in that it does not address a specific test. Rather, it is an introductory guide for new users of other standard exfoliation test methods, (see Terminology G 15 for definition of exfoliation). 1.2 This guide covers aspects of specimen preparation, exposure, inspection, and evaluation for conducting exfoliation tests on aluminum alloys in both laboratory accelerated environments and in natural, outdoor atmospheres. The intent is to clarify any gaps in existent test methods. 1.3 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  1. Standard test method for galling resistance of material couples

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers a laboratory test that ranks the galling resistance of material couples using a quantitative measure. Bare metals, alloys, nonmetallic materials, coatings, and surface modified materials may be evaluated by this test method. 1.2 This test method is not designed for evaluating the galling resistance of material couples sliding under lubricated conditions, because galling usually will not occur under lubricated sliding conditions using this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. A standard for test reliability in group research.

    Science.gov (United States)

    Ellis, Jules L

    2013-03-01

    Many authors adhere to the rule that test reliabilities should be at least .70 or .80 in group research. This article introduces a new standard according to which reliabilities can be evaluated. This standard is based on the costs or time of the experiment and of administering the test. For example, if test administration costs are 7 % of the total experimental costs, the efficient value of the reliability is .93. If the actual reliability of a test is equal to this efficient reliability, the test size maximizes the statistical power of the experiment, given the costs. As a standard in experimental research, it is proposed that the reliability of the dependent variable be close to the efficient reliability. Adhering to this standard will enhance the statistical power and reduce the costs of experiments.

  3. Standardized Testing for Outcome Assessment: Analysis of the Educational Testing Systems MBA Tests

    Science.gov (United States)

    Wright, Robert E.

    2010-01-01

    The use of standardized tests for outcome assessment has grown dramatically in recent years. Two driving factors have been the No Child Left Behind legislation, and the increase in outcome assessment measures by accrediting agencies such as AACSB, the international accrediting body for business schools. Despite the growth in usage, little effort…

  4. National Unmanned Aerial System Standardized Performance Testing and Rating (NUSTAR)

    Science.gov (United States)

    Kopardekar, Parimal

    2016-01-01

    The overall objective of the NUSTAR Capability is to offer standardized tests and scenario conditions to assess performance of the UAS. The following are goals of the NU-STAR: 1. Create a prototype standardized tests and scenarios that vehicles can be tested against. 2. Identify key performance parameters of all UAS and their standardized measurement strategy. 3. Develop standardized performance reporting method (e.g., consumer report style) to assist prospective buyers. 4. Identify key performance metrics that could be used by judged towards overall safety of the UAS and operations. 5. If vehicle certification standard is made by a regulatory agency, the performance of individual UAS could be compared against the minimum requirement (e.g., sense and avoid detection time, stopping distance, kinetic energy, etc.).

  5. Pad-weighing test performed with standardized bladder volume

    DEFF Research Database (Denmark)

    Lose, G; Rosenkilde, P; Gammelgaard, J

    1988-01-01

    with a standardized bladder volume (50% of the cystometric bladder capacity). Twenty-five female patients with stress or mixed incontinence underwent two separate tests. Test-retest results were highly correlated (r = 0.97, p less than 0.001). Nonetheless, analysis of test-retest differences revealed a variation up...... to +/- 24 g between two tests. It is concluded that this setup (i.e., standardized bladder volume) of the one-hour pad-weighing test allows for a more reliable assessment of urinary incontinence for quantitative purposes.......The result of the one-hour pad-weighing test proposed by the International Continence Society has been demonstrated to depend on the urine load during the test. To increase reproducibility of the pad-weighing test by minimizing the influence of variation in urine load the test was done...

  6. Profile Analysis of the Universal Nonverbal Intelligence Test Standardization Sample.

    Science.gov (United States)

    Wilhoit, Brian E.; McCallum, R. Steve

    2002-01-01

    A normative typology was developed and applied using multivariate profile analysis of subtest scores of the Universal Nonverbal Intelligence Test (UNIT) standardization sample. The results yielded a seven-profile cluster solution for the Extended Battery, and a six-profile cluster solution for the Standard Battery. Additionally, the results lend…

  7. Testing the minimal supersymmetric standard model with the mass ...

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics; Volume 69; Issue 5. Testing the minimal supersymmetric standard model with the mass ... We review the currently most accurate evaluation of the boson mass, , in the minimal supersymmetric standard model (MSSM). It consists of a full one-loop calculation, including the ...

  8. 42 CFR 493.1365 - Standard; PPM testing personnel responsibilities.

    Science.gov (United States)

    2010-10-01

    ... using a microscope limited to a brightfield or a phase/contrast microscope. Laboratories Performing... Nonwaived Testing Laboratories Performing Provider-Performed Microscopy (ppm) Procedures § 493.1365 Standard...

  9. Stress Optical Coefficient, Test Methodology, and Glass Standard Evaluation

    Science.gov (United States)

    2016-05-01

    ARL-TN-0756 ● MAY 2016 US Army Research Laboratory Stress Optical Coefficient, Test Methodology, and Glass Standard Evaluation...Stress Optical Coefficient, Test Methodology, and Glass Standard Evaluation by Clayton M Weiss Oak Ridge Institute for Science and Education...materials under stress, which is represented by the material property of stress optical coefficient, can be used to evaluate glass samples of known and

  10. Balancing standardized testing with personalized training in surgery

    OpenAIRE

    Ahmed A; Abid MA; Bhatti NI

    2016-01-01

    Aadil Ahmed, Muhammad Abbas Abid, Nasir I Bhatti Department of Otolaryngology-Head and Neck Surgery, The Johns Hopkins School of Medicine, Baltimore, MD, USA Abstract: Students pursuing a medical career in the US are subject to standardized testing at regular intervals. These standardized tests not only quantify the milestones students have already achieved, but also define the path for future achievements. The purpose of these examinations is to help students become self-directed, l...

  11. Multilevel Linkages between State Standards, Teacher Standards, and Student Achievement: Testing External versus Internal Standards-Based Education Models

    Science.gov (United States)

    Lee, Jaekyung; Liu, Xiaoyan; Amo, Laura Casey; Wang, Weichun Leilani

    2014-01-01

    Drawing on national and state assessment datasets in reading and math, this study tested "external" versus "internal" standards-based education models. The goal was to understand whether and how student performance standards work in multilayered school systems under No Child Left Behind Act of 2001 (NCLB). Under the…

  12. Standard Test Method for Environmental Resistance of Aerospace Transparencies

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers determination of the effects of exposure to thermal shock, condensing humidity, and simulated weather on aerospace transparent enclosures. 1.2 This test method is not recommended for quality control nor is it intended to provide a correlation to actual service life. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3.1 Exceptions—Certain inch-pound units are furnished in parentheses (not mandatory) and certain temperatures in Fahrenheit associated with other standards are also furnished. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  13. A standardized test battery for the study of synesthesia.

    Science.gov (United States)

    Eagleman, David M; Kagan, Arielle D; Nelson, Stephanie S; Sagaram, Deepak; Sarma, Anand K

    2007-01-15

    Synesthesia is an unusual condition in which stimulation of one modality evokes sensation or experience in another modality. Although discussed in the literature well over a century ago, synesthesia slipped out of the scientific spotlight for decades because of the difficulty in verifying and quantifying private perceptual experiences. In recent years, the study of synesthesia has enjoyed a renaissance due to the introduction of tests that demonstrate the reality of the condition, its automatic and involuntary nature, and its measurable perceptual consequences. However, while several research groups now study synesthesia, there is no single protocol for comparing, contrasting and pooling synesthetic subjects across these groups. There is no standard battery of tests, no quantifiable scoring system, and no standard phrasing of questions. Additionally, the tests that exist offer no means for data comparison. To remedy this deficit we have devised the Synesthesia Battery. This unified collection of tests is freely accessible online (http://www.synesthete.org). It consists of a questionnaire and several online software programs, and test results are immediately available for use by synesthetes and invited researchers. Performance on the tests is quantified with a standard scoring system. We introduce several novel tests here, and offer the software for running the tests. By presenting standardized procedures for testing and comparing subjects, this endeavor hopes to speed scientific progress in synesthesia research.

  14. A standardized test battery for the study of synesthesia

    Science.gov (United States)

    Eagleman, David M.; Kagan, Arielle D.; Nelson, Stephanie S.; Sagaram, Deepak; Sarma, Anand K.

    2014-01-01

    Synesthesia is an unusual condition in which stimulation of one modality evokes sensation or experience in another modality. Although discussed in the literature well over a century ago, synesthesia slipped out of the scientific spotlight for decades because of the difficulty in verifying and quantifying private perceptual experiences. In recent years, the study of synesthesia has enjoyed a renaissance due to the introduction of tests that demonstrate the reality of the condition, its automatic and involuntary nature, and its measurable perceptual consequences. However, while several research groups now study synesthesia, there is no single protocol for comparing, contrasting and pooling synesthetic subjects across these groups. There is no standard battery of tests, no quantifiable scoring system, and no standard phrasing of questions. Additionally, the tests that exist offer no means for data comparison. To remedy this deficit we have devised the Synesthesia Battery. This unified collection of tests is freely accessible online (http://www.synesthete.org). It consists of a questionnaire and several online software programs, and test results are immediately available for use by synesthetes and invited researchers. Performance on the tests is quantified with a standard scoring system. We introduce several novel tests here, and offer the software for running the tests. By presenting standardized procedures for testing and comparing subjects, this endeavor hopes to speed scientific progress in synesthesia research. PMID:16919755

  15. Cognitive Fatigue Influences Students’ Performance on Standardized Tests

    DEFF Research Database (Denmark)

    Sievertsen, Hans Henrik; Gino, Francesca; Piovesan, Marco

    2016-01-01

    We identify one potential source of bias that influences children’s performance on standardized tests and that is predictable based on psychological theory: the time at which students take the test. Using test data for all children attending Danish public schools between school years 2009....../10 and 2012/13, we find that, for every hour later in the day, test scores decrease by 0.9% of an SD. In addition, a 20- to 30-minute break improves average test scores. Time of day affects students’ test performance because, over the course of a regular day, students’ mental resources get taxed. Thus......, as the day wears on, students become increasingly fatigued and consequently more likely to underperform on a standardized test....

  16. Cognitive Fatigue Influences Students’ Performance on Standardized Tests

    DEFF Research Database (Denmark)

    Sievertsen, Hans Henrik; Gino, Francesca; Piovesan, Marco

    2016-01-01

    We identify one potential source of bias that influences children’s performance on standardized tests and that is predictable based on psychological theory: the time at which students take the test. Using test data for all children attending Danish public schools between school years 2009......, as the day wears on, students become increasingly fatigued and consequently more likely to underperform on a standardized test......./10 and 2012/13, we find that, for every hour later in the day, test scores decrease by 0.9% of an SD. In addition, a 20- to 30-minute break improves average test scores. Time of day affects students’ test performance because, over the course of a regular day, students’ mental resources get taxed. Thus...

  17. Standard test method for determination of resistance to staining

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method is intended to determine the resistance to staining of ceramic tile surfaces. 1.2 The resistance to staining is determined by maintaining test solutions in contact with ceramic tile surfaces for a specified period of time. After exposure, the surface is cleaned in a defined manner, and the test specimens are inspected visually for change. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  18. Addressing Standardized Testing through a Novel Assesment Model

    Science.gov (United States)

    Schifter, Catherine C.; Carey, Martha

    2014-01-01

    The No Child Left Behind (NCLB) legislation spawned a plethora of standardized testing services for all the high stakes testing required by the law. We argue that one-size-fits all assessments disadvantage students who are English Language Learners, in the USA, as well as students with limited economic resources, special needs, and not reading on…

  19. Standardized Test Results: An Opportunity for English Program Improvement

    Science.gov (United States)

    Jiménez, Maureyra; Rodríguez, Caroll; Rey Paba, Lourdes

    2017-01-01

    This case study explores the relationship between the results obtained by a group of Industrial Engineering students on a national standardized English test and the impact these results had on language program improvement. The instruments used were interviews, document analysis, observations, surveys, and test results analysis. Findings indicate…

  20. CONSTRUCTION AND STANDARDIZATION OF A BATTERY OF BRAILLE SKILL TESTS.

    Science.gov (United States)

    BOURGEAULT, STANLEY E.; WOODCOCK, RICHARD W.

    A BATTERY OF TESTS WAS DEVELOPED AND STANDARDIZED TO MEASURE MASTERY OF TWO BRAILLE CODES--THE GRADE 2 LITERARY CODE AND THE NEMETH CODE FOR MATHEMATICAL NOTATION. DESIGNATED AS THE "COLORADO BRAILLE BATTERY," THESE TESTS PROVIDED OBJECTIVE MEASUREMENT DATA REGARDING A STUDENT'S OVERALL DEVELOPMENT IN BRAILLE, AS WELL AS A MEANS OF…

  1. Standards for Educational and Psychological Testing, 2014 Edition

    Science.gov (United States)

    American Educational Research Association (AERA), 2014

    2014-01-01

    Developed jointly by the American Educational Research Association, American Psychological Association, and the National Council on Measurement in Education, "Standards for Educational and Psychological Testing" (Revised 2014) addresses professional and technical issues of test development and use in education, psychology, and…

  2. BSAC standardized disc susceptibility testing method (version 11).

    Science.gov (United States)

    Howe, R A; Andrews, J M

    2012-12-01

    This article highlights key amendments incorporated into version 11 of the BSAC standardized disc susceptibility testing method, available as Supplementary data at JAC Online (http://jac.oxfordjournals.org/) and on the BSAC web site (http://bsac.org.uk/susceptibility/guidelines-standardized-disc-susceptibility-testing-method/). The basic disc susceptibility testing method remains unchanged, but there have been a number of alterations to the interpretive criteria for certain organism/drug combinations due to continuing harmonization with the EUCAST MIC breakpoints and constant efforts to improve the reliability and clinical applicability of the guidance.

  3. Standard Guide for Conducting Corrosion Tests in Field Applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This guide covers procedures for conducting corrosion tests in plant equipment or systems under operating conditions to evaluate the corrosion resistance of engineering materials. It does not cover electrochemical methods for determining corrosion rates. 1.1.1 While intended primarily for immersion tests, general guidelines provided can be applicable for exposure of test specimens in plant atmospheres, provided that placement and orientation of the test specimens is non-restrictive to air circulation. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See also 10.4.2.

  4. A comparison of standard acute toxicity tests with rapid-screening toxicity tests

    Energy Technology Data Exchange (ETDEWEB)

    Toussaint, M.W. [Geo-Centers, Inc., Fort Washington, MD (United States); Shedd, T.R. [Army Biomedical Research and Development Lab., Frederick, MD (United States); Schalie, W.H. van der [Environmental Protection Agency, Washington, DC (United States); Leather, G.R. [Hood Coll., Frederick, MD (United States). Dept. of Biology

    1995-05-01

    This study compared the relative sensitivity of five inexpensive, rapid toxicity tests to the sensitivity of five standard aquatic acute toxicity tests through literature review and testing. The rapid toxicity tests utilized organisms that require little culturing or handling prior to testing: a freshwater rotifer (Branchionus calyciflorus); brine shrimp (Artemia salina); lettuce (Lactuca sativa); and two microbial tests (Photobacterium phosphoreum--Microtox{reg_sign} test, and a mixture of bacterial species--the Polytox{reg_sign} test). Standard acute toxicity test species included water fleas (Daphnia magna and Ceriodaphnia dubia), green algae (Selenastrum capricornutum), fathead minnows (Pimephales promelas), and mysid shrimp (Mysidopsis bahia). Sensitivity comparisons between rapid and standard acute toxicity tests were based on LC50/EC50 data from 11 test chemicals. Individually, the lettuce and rotifer tests ranked most similar in sensitivity to the standard tests, while Microtox fell just outside the range of sensitivities represented by the group of standard acute toxicity tests. The brine shrimp and Polytox tests were one or more orders of magnitude different from the standard acute toxicity tests for most compounds. The lettuce, rotifer, and Microtox tests could be used as a battery for preliminary toxicity screening of chemicals. Further evaluation of complex real-world environmental samples is recommended.

  5. Standard test methods for vitrified ceramic materials for electrical applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1986-01-01

    1.1 These test methods outline procedures for testing samples of vitrified ceramic materials that are to be used as electrical insulation. Where specified limits are mentioned herein, they shall not be interpreted as specification limits for completed insulators. 1.2 These test methods are intended to apply to unglazed specimens, but they may be equally suited for testing glazed specimens. The report section shall indicate whether glazed or unglazed specimens were tested. 1.3 The test methods appear as follows: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precaution statements are given in 11.3, 13.5, and 15.3.

  6. Standard practice for modified salt spray (fog) testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This practice covers and sets forth conditions for five modifications in salt spray (fog) testing for specification purposes. These are in chronological order of their development: 1.1.1 Annex A1, acetic acid-salt spray test, continuous. 1.1.2 Annex A2, cyclic acidified salt spray test. 1.1.3 Annex A3, seawater acidified test, cyclic (SWAAT). 1.1.4 Annex A4, SO2 salt spray test, cyclic. 1.1.5 Annex A5, dilute electrolyte cyclic fog dry test. 1.2 This practice does not prescribe the type of modification, test specimen or exposure periods to be used for a specific product, nor the interpretation to be given to the results. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to consult and establish appropriate safety and health practices and determine the applicabilit...

  7. Standard Operating Procedure for Accelerated Corrosion Testing at ARL

    Science.gov (United States)

    2017-11-01

    ARL-TN-0855 ● NOV 2017 US Army Research Laboratory Standard Operating Procedure for Accelerated Corrosion Testing at ARL by... Corrosion Testing at ARL by Thomas A Considine Weapons and Materials Research Directorate, ARL Approved for public... Corrosion Testing at ARL 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Thomas A Considine 5d. PROJECT NUMBER NA

  8. ISO standards on test methods for water radioactivity monitoring.

    Science.gov (United States)

    Calmet, D; Ameon, R; Bombard, A; Forte, M; Fournier, M; Herranz, M; Jerome, S; Kwakman, P; Llaurado, M; Tokonami, S

    2013-11-01

    Water is vital to humans and each of us needs at least 1.5L of safe water a day to drink. Beginning as long ago as 1958 the World Health Organization (WHO) has published guidelines to help ensure water is safe to drink. Focused from the start on monitoring radionuclides in water, and continually cooperating with WHO, the International Standardization Organization (ISO) has been publishing standards on radioactivity test methods since 1978. As reliable, comparable and 'fit for purpose' results are an essential requirement for any public health decision based on radioactivity measurements, international standards of tested and validated radionuclide test methods are an important tool for production of such measurements. This paper presents the ISO standards already published that could be used as normative references by testing laboratories in charge of radioactivity monitoring of drinking water as well as those currently under drafting and the prospect of standardized fast test methods in response to a nuclear accident. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Standard test methods for forming superplastic metallic sheet

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods describe procedures for determining the biaxial formability of a superplastic metallic sheet in a circular die. 1.2 The intent of these test methods are primarily to be used as tests of superplasticity as measured by the ability to form to a prescribed depth in a die cavity without rupturing. These test methods can also be used to generate material for the measurement of cavitation in the formed part. These can be used as go/no go criteria for qualification to a specification. 1.3 These test methods have been used successfully with aluminum alloys. The use of these test methods on other metals should be verified. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of ...

  10. Standard Test Method for Abrasive Wear Resistance of Cemented

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the determination of abrasive wear resistance of cemented carbides. 1.2 The values stated in inch-pound units are to be regarded as the standard. The SI equivalents of inch-pound units are in parentheses and may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. Standard test method for using atmospheric pressure rotating cage

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers a generally accepted procedure to conduct the rotating cage (RC) experiment under atmospheric pressure. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  12. Sunscreen standards tested with differently filtered solar simulators.

    Science.gov (United States)

    Sayre, R M; Stanfield, J; Bush, A J; Lott, D L

    2001-12-01

    The COLIPA standard for solar simulators permits a range of spectral filtration. Published studies comparing the SPFs of sunscreen formulas show that a range of SPFs is generally expected between laboratories. Specifically, three studies determining the SPFs of sunscreen standards have been performed in a series of laboratories and differences exceeding 50% have been reported. No studies to date have specifically examined potential differences in performance of Standard Sunscreen Test Formulas with varying solar simulator spectra within the permitted range of optical filtration. In a paired clinical trial, two SPF standard sunscreen formulas were tested using two solar simulators that complied with the COLIPA standard for solar simulators but were filtered differently. One solar simulator was filtered as supplied by the manufacturer and delivered a high percentage of UVB; the other solar simulator was modified by removing the visible absorbing filter to deliver energy more closely resembling sunlight in the UVA-1 part of the spectrum, with a lower percentage of UVB. The result was that the SPF of each standard sunscreen was almost 50% greater with the unmodified solar simulator than with the modified solar simulator. In vitro evaluation of the sunscreen standards predicted similar differences due to the spectral differences of the solar simulators, which appears to rule out reciprocity failure. However, reciprocity failure of the control MEDs was observed. The total intensity of the modified lamp was approximately 3 times that of the unmodified lamp.

  13. Standard Setting for a Test of Pharmacy Practice Knowledge: Application in High-Stakes Testing.

    Science.gov (United States)

    Fielding, David W.; And Others

    1996-01-01

    Three approaches to setting the evaluation standards for testing pharmacy practice knowledge of pharmaceutical students are discussed and compared: relative standards; absolute standards; and a compromise approach using various sources of evaluation information. The application of the different approaches to a 120-item assessment previously…

  14. Standard Test Method for Thermal Oxidative Resistance of Carbon Fibers

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1982-01-01

    1.1 This test method covers the apparatus and procedure for the determination of the weight loss of carbon fibers, exposed to ambient hot air, as a means of characterizing their oxidative resistance. 1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units which are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard information, see Section 8.

  15. Standardization of Solar Mirror Reflectance Measurements - Round Robin Test: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Meyen, S.; Lupfert, E.; Fernandez-Garcia, A.; Kennedy, C.

    2010-10-01

    Within the SolarPaces Task III standardization activities, DLR, CIEMAT, and NREL have concentrated on optimizing the procedure to measure the reflectance of solar mirrors. From this work, the laboratories have developed a clear definition of the method and requirements needed of commercial instruments for reliable reflectance results. A round robin test was performed between the three laboratories with samples that represent all of the commercial solar mirrors currently available for concentrating solar power (CSP) applications. The results show surprisingly large differences in hemispherical reflectance (sh) of 0.007 and specular reflectance (ss) of 0.004 between the laboratories. These differences indicate the importance of minimum instrument requirements and standardized procedures. Based on these results, the optimal procedure will be formulated and validated with a new round robin test in which a better accuracy is expected. Improved instruments and reference standards are needed to reach the necessary accuracy for cost and efficiency calculations.

  16. Standard Test Method for Laboratory Aging of Sandwich Constructions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers the determination of the resistance of sandwich panels to severe exposure conditions as measured by the change in selected properties of the material after exposure. The exposure cycle to which the specimen is subjected is an arbitrary test having no correlation with natural weathering conditions. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  17. Standardized Testing and School Segregation: Like Tinder for Fire?

    Science.gov (United States)

    Knoester, Matthew; Au, Wayne

    2017-01-01

    Recent research suggests that high-stakes standardized testing has played a negative role in the segregation of children by race and class in schools. In this article we review research on the overall effects of segregation, the positive and negative aspects of how desegregation plans were carried out following the 1954 Supreme Court decision…

  18. Standardization in Cryogenic Insulation Systems Testing and Performance Data

    Science.gov (United States)

    Fesmire, James E.

    The close relationship between industrial energy use and cryogenics drives the need for optimized thermal insulation systems. Emerging cryofuels usage is enabled by adequate isolation of the liquid hydrogen or liquefied natural gas from the ambient environment. Thermal performance data for the total insulation system, as rendered, are essential for both engineering designs and cost-benefit decisions involving comparisons among alternatives. These data are obtained through rigorous testing with suitable apparatus and repeatable methods. Properly defined terminology, analysis, and reporting are also vital. Advances in cryogenic insulation test apparatus and methods have led to the recent addition of two new technical standards of ASTM International: C1774 - Standard Guide for Thermal Performance Testing of Cryogenic InsulationSystems and C740 - Standard Guide for Evacuated Reflective Cryogenic Insulation. Among the different techniques described in the new standards is the cylindrical boiloff calorimeter for absolute heat measurement over the full range of vacuum pressure conditions. The details of this apparatus, test method, and data analysis are given. Benchmark thermal performance data, including effective thermal conductivity (ke) and heat flux (q) for the boundary temperatures of 293 K and 77 K, are given for a number of different multilayer insulation (MLI) systems in comparison with data for other commonly-used insulation systems including perlite powder, fiberglass, polyurethane foam, and aerogels.

  19. Student Laptop Use and Scores on Standardized Tests

    Science.gov (United States)

    Kposowa, Augustine J.; Valdez, Amanda D.

    2013-01-01

    Objectives: The primary objective of the study was to investigate the relationship between ubiquitous laptop use and academic achievement. It was hypothesized that students with ubiquitous laptops would score on average higher on standardized tests than those without such computers. Methods: Data were obtained from two sources. First, demographic…

  20. Opting Out: Parents Creating Contested Spaces to Challenge Standardized Tests

    Science.gov (United States)

    Mitra, Dana; Mann, Bryan; Hlavacik, Mark

    2016-01-01

    We explore how the opt-out movement has responded to the combination of a stringent federal policy with weak and often variable implementation among the states. Gaps between federal expectations and states' understandings of just how to make NCLB's demands a reality have created policy ambiguity. Parents who oppose standardized testing have…

  1. Standard-D hydrogen monitoring system acceptance test

    Energy Technology Data Exchange (ETDEWEB)

    Lott, D.T., Westinghouse Hanford

    1996-05-24

    This document details the results of the field Acceptance Testing of the Standard-D Hydrogen Monitoring System on the waste tank exhaust stacks in 241-AW and 241-AN tank farm. The monitors will be used to measure hydrogen and ammonia from the exhaust stacks.

  2. Report on the Standardization Project "Formal Methods in Conformance Testing"

    NARCIS (Netherlands)

    Baumgarten, B.; Hogrefe, D.; Heymer, S.; Burkhardt, H.-J.; Giessler, A.; Tretmans, G.J.

    1996-01-01

    This paper presents the latest developments in the “Formal Methods in Conformance Testing��? (FMCT) project of ISO and ITU–T. The project has been initiated to study the role of formal description techniques in the conformance testing process. The goal is to develop a standard that defines the

  3. Development of Standardized Material Testing Protocols for Prosthetic Liners.

    Science.gov (United States)

    Cagle, John C; Reinhall, Per G; Hafner, Brian J; Sanders, Joan E

    2017-04-01

    A set of protocols was created to characterize prosthetic liners across six clinically relevant material properties. Properties included compressive elasticity, shear elasticity, tensile elasticity, volumetric elasticity, coefficient of friction (CoF), and thermal conductivity. Eighteen prosthetic liners representing the diverse range of commercial products were evaluated to create test procedures that maximized repeatability, minimized error, and provided clinically meaningful results. Shear and tensile elasticity test designs were augmented with finite element analysis (FEA) to optimize specimen geometries. Results showed that because of the wide range of available liner products, the compressive elasticity and tensile elasticity tests required two test maxima; samples were tested until they met either a strain-based or a stress-based maximum, whichever was reached first. The shear and tensile elasticity tests required that no cyclic conditioning be conducted because of limited endurance of the mounting adhesive with some liner materials. The coefficient of friction test was based on dynamic coefficient of friction, as it proved to be a more reliable measurement than static coefficient of friction. The volumetric elasticity test required that air be released beneath samples in the test chamber before testing. The thermal conductivity test best reflected the clinical environment when thermal grease was omitted and when liner samples were placed under pressure consistent with load bearing conditions. The developed procedures provide a standardized approach for evaluating liner products in the prosthetics industry. Test results can be used to improve clinical selection of liners for individual patients and guide development of new liner products.

  4. Standard test method for evaluating springback of sheet metal using the demeri split ring test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method provides a means of evaluating the springback behavior of metals in a test that simulates a stretch-draw forming process. The test method can also be used to calibrate computer simulation codes by selecting appropriate control parameters to achieve satisfactory correlation between simulation and test results. 1.2 The values stated in SI units are standard. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Standard terminology relating to fatigue and fracture testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This terminology contains definitions, definitions of terms specific to certain standards, symbols, and abbreviations approved for use in standards on fatigue and fracture testing. The definitions are preceded by two lists. The first is an alphabetical listing of symbols used. (Greek symbols are listed in accordance with their spelling in English.) The second is an alphabetical listing of relevant abbreviations. 1.2 This terminology includes Annex A1 on Units and Annex A2 on Designation Codes for Specimen Configuration, Applied Loading, and Crack or Notch Orientation.

  6. Standardized Testing Practices: Effect on Graduation and NCLEX® Pass Rates.

    Science.gov (United States)

    Randolph, Pamela K

    The use standardized testing in pre-licensure nursing programs has been accompanied by conflicting reports of effective practices. The purpose of this project was to describe standardized testing practices in one states' nursing programs and discover if the use of a cut score or oversight of remediation had any effect on (a) first time NCLEX® pass rates, (b) on-time graduation (OTG) or (c) the combination of (a) and (b). Administrators of 38 nursing programs in one Southwest state were sent surveys; surveys were returned by 34 programs (89%). Survey responses were compared to each program's NCLEX pass rate and on-time graduation rate; t-tests were conducted for significant differences associated with a required minimum score (cut score) and oversight of remediation. There were no significant differences in NCLEX pass or on-time graduation rates related to establishment of a cut score. There was a significant difference when the NCLEX pass rate and on-time graduation rate were combined (Outcome Index "OI") with significantly higher program outcomes (P=.02.) for programs without cut-scores. There were no differences associated with faculty oversight of remediation. The results of this study do not support establishment of a cut-score when implementing a standardized testing. Copyright © 2016. Published by Elsevier Inc.

  7. Standard practices for verification of speed for material testing machines

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These practices cover procedures and requirements for the calibration and verification of testing machine speed by means of standard calibration devices. This practice is not intended to be complete purchase specifications for testing machines. 1.2 These practices apply to the verification of the speed application and measuring systems associated with the testing machine, such as a scale, dial, marked or unmarked recorder chart, digital display, setting, etc. In all cases the buyer/owner/user must designate the speed-measuring system(s) to be verified. 1.3 These practices give guidance, recommendations, and examples, specific to electro-mechanical testing machines. The practice may also be used to verify actuator speed for hydraulic testing machines. 1.4 This standard cannot be used to verify cycle counting or frequency related to cyclic fatigue testing applications. 1.5 Since conversion factors are not required in this practice, either SI units (mm/min), or English [in/min], can be used as the standa...

  8. RF tests on the Etam Standard C antenna

    Science.gov (United States)

    Price, R.

    1982-05-01

    Radiometric measurements on the Etam Standard C antenna are described in this paper. Gain-to-noise temperature ratio (G/T), receive and transmit gain, noise temperature, return loss, and port-to-port isolation were measured, and communication and tracking patterns taken. Because of the very low spectral flux densities in the 14/11-GHz bands, it was necessary to use radiometric methods for measuring G/T, gain and temperature. Although in Standard A antennas Y-factors range between 3 and 6 dB, in Standard C antennas they are only 0.4-0.5 dB. Thus, errors and uncertainties, which are negligible in a 6/4-GHz test, become major at 14/11 GHz. This difficulty was overcome at Etam by applying a refinement in switched radiometry, which resulted in the collection of a large amount of useful data.

  9. Standard Practice for Quality Management Systems for Nondestructive Testing Agencies

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This practice covers general requirements for the establishment and maintenance of a quality management system for agencies engaged in nondestructive testing (NDT). 1.2 This practice utilizes criteria contained in Practice E 543. 1.3 This practice utilizes criteria contained in American National Standard ANSI/ISO/ASQ Q9001–2000, Quality management systems—Requirements. 1.4 This practice recognizes the importance of establishing minimum safety criteria. 1.5 The use of SI or inch-pound units, or combinations thereof, will be the responsibility of the technical committee whose standards are referred to in this standard. 1.6 This practice does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this practice to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Comparison of three standardized disc susceptibility testing methods for colistin.

    Science.gov (United States)

    Tan, Thean Yen; Ng, Lily Siew Yong

    2006-10-01

    With increasing antibiotic resistance in Gram-negative bacteria, the use of the polymyxins has increased in recent years. Antibiotic disc susceptibility testing remains the most widely used method in clinical laboratories, but there is very little data on the accuracy of disc testing methods for colistin. In this study, the accuracy of three standardized methods of disc susceptibility testing for colistin was compared with agar dilution. A total of 228 clinical isolates of Acinetobacter spp., Pseudomonas aeruginosa and Enterobacteriaceae were included in the study. Isolates were tested by agar dilution for susceptibility to colistin, and results were compared with those obtained by three disc susceptibility testing methods (product insert based on CLSI methodology, British BSAC and French SFM). Colistin displayed good activity against Acinetobacter spp., Klebsiella spp. and Escherichia coli (MIC(90) 2 mg/L) but was less active against P. aeruginosa (MIC(90) 4 mg/L) and Enterobacter spp. (MIC(90) >or= 128 mg/L). Totally, 81%, 79% and 89% of colistin-resistant isolates were falsely reported as susceptible when tested by the product insert, BSAC and SFM testing methods, respectively. There were no false-resistant results. Disc susceptibility testing methods are unreliable at detecting colistin resistance. Dilution methods should be the method of choice for susceptibility testing of colistin.

  11. Balancing standardized testing with personalized training in surgery.

    Science.gov (United States)

    Ahmed, Aadil; Abid, Muhammad Abbas; Bhatti, Nasir I

    2017-01-01

    Students pursuing a medical career in the US are subject to standardized testing at regular intervals. These standardized tests not only quantify the milestones students have already achieved, but also define the path for future achievements. The purpose of these examinations is to help students become self-directed, lifelong learners - an essential attribute of a medical professional. However, whether preparing for these examinations actually makes students such disciplined learners needs to be examined. Especially during residency training with its limited time and unpredictable exposure, trainees must learn in the most efficient way for their learning styles, and thus develop attributes that will be helpful to them in their medical career. In this review, we propose that a personalized, learner-centered approach tailored to residents' educational needs and preferences can not only fulfill learning interests and objectives but also serve as a time-efficient and cost-effective approach for graduate medical education.

  12. Standard practice for preparing, cleaning, and evaluating corrosion test specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This practice covers suggested procedures for preparing bare, solid metal specimens for tests, for removing corrosion products after the test has been completed, and for evaluating the corrosion damage that has occurred. Emphasis is placed on procedures related to the evaluation of corrosion by mass loss and pitting measurements. (Warning—In many cases the corrosion product on the reactive metals titanium and zirconium is a hard and tightly bonded oxide that defies removal by chemical or ordinary mechanical means. In many such cases, corrosion rates are established by mass gain rather than mass loss.) 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see 1 and 7.2.

  13. Test of a Power Transfer Model for Standardized Electrofishing

    Science.gov (United States)

    Miranda, L.E.; Dolan, C.R.

    2003-01-01

    Standardization of electrofishing in waters with differing conductivities is critical when monitoring temporal and spatial differences in fish assemblages. We tested a model that can help improve the consistency of electrofishing by allowing control over the amount of power that is transferred to the fish. The primary objective was to verify, under controlled laboratory conditions, whether the model adequately described fish immobilization responses elicited with various electrical settings over a range of water conductivities. We found that the model accurately described empirical observations over conductivities ranging from 12 to 1,030 ??S/cm for DC and various pulsed-DC settings. Because the model requires knowledge of a fish's effective conductivity, an attribute that is likely to vary according to species, size, temperature, and other variables, a second objective was to gather available estimates of the effective conductivity of fish to examine the magnitude of variation and to assess whether in practical applications a standard effective conductivity value for fish may be assumed. We found that applying a standard fish effective conductivity of 115 ??S/cm introduced relatively little error into the estimation of the peak power density required to immobilize fish with electrofishing. However, this standard was derived from few estimates of fish effective conductivity and a limited number of species; more estimates are needed to validate our working standard.

  14. Standard Waste Box Lid Screw Removal Option Testing

    Energy Technology Data Exchange (ETDEWEB)

    Anast, Kurt Roy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-11

    This report provides results from test work conducted to resolve the removal of screws securing the standard waste box (SWB) lids that hold the remediated nitrate salt (RNS) drums. The test work evaluated equipment and process alternatives for removing the 42 screws that hold the SWB lid in place. The screws were secured with a red Loctite thread locker that makes removal very difficult because the rivets that the screw threads into would slip before the screw could be freed from the rivet, making it impossible to remove the screw and therefore the SWB lid.

  15. Balancing standardized testing with personalized training in surgery

    Directory of Open Access Journals (Sweden)

    Ahmed A

    2016-12-01

    Full Text Available Aadil Ahmed, Muhammad Abbas Abid, Nasir I Bhatti Department of Otolaryngology-Head and Neck Surgery, The Johns Hopkins School of Medicine, Baltimore, MD, USA Abstract: Students pursuing a medical career in the US are subject to standardized testing at regular intervals. These standardized tests not only quantify the milestones students have already achieved, but also define the path for future achievements. The purpose of these examinations is to help students become self-directed, lifelong learners – an essential attribute of a medical professional. However, whether preparing for these examinations actually makes students such disciplined learners needs to be examined. Especially during residency training with its limited time and unpredictable exposure, trainees must learn in the most efficient way for their learning styles, and thus develop attributes that will be helpful to them in their medical career. In this review, we propose that a personalized, learner-centered approach tailored to residents’ educational needs and preferences can not only fulfill learning interests and objectives but also serve as a time-efficient and cost-effective approach for graduate medical education. Keywords: standardized testing, personalized training, surgery

  16. Validity and Reliability of Baseline Testing in a Standardized Environment.

    Science.gov (United States)

    Higgins, Kathryn L; Caze, Todd; Maerlender, Arthur

    2017-08-11

    The Immediate Postconcussion Assessment and Cognitive Testing (ImPACT) is a computerized neuropsychological test battery commonly used to determine cognitive recovery from concussion based on comparing post-injury scores to baseline scores. This model is based on the premise that ImPACT baseline test scores are a valid and reliable measure of optimal cognitive function at baseline. Growing evidence suggests that this premise may not be accurate and a large contributor to invalid and unreliable baseline test scores may be the protocol and environment in which baseline tests are administered. This study examined the effects of a standardized environment and administration protocol on the reliability and performance validity of athletes' baseline test scores on ImPACT by comparing scores obtained in two different group-testing settings. Three hundred-sixty one Division 1 cohort-matched collegiate athletes' baseline data were assessed using a variety of indicators of potential performance invalidity; internal reliability was also examined. Thirty-one to thirty-nine percent of the baseline cases had at least one indicator of low performance validity, but there were no significant differences in validity indicators based on environment in which the testing was conducted. Internal consistency reliability scores were in the acceptable to good range, with no significant differences between administration conditions. These results suggest that athletes may be reliably performing at levels lower than their best effort would produce.

  17. NedWind 25 Blade Testing at NREL for the European Standards Measurement and Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    Larwood, S.; Musial, W.; Freebury, G.; Beattie, A.G.

    2001-04-19

    In the mid-90s the European community initiated the Standards, Measurements, and Testing (SMT) program to harmonize testing and measurement procedures in several industries. Within the program, a project was carried out called the European Wind Turbine Testing Procedure Development. The second part of that project, called Blade Test Methods and Techniques, included the United States and was devised to help blade-testing laboratories harmonize their testing methods. This report provides the results of those tests conducted by the National Renewable Energy Laboratory.

  18. Standard practice for conducting moist SO2 tests

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This practice covers the apparatus and procedure to be used in conducting qualitative assessment tests in accordance with the requirements of material or product specifications by means of specimen exposure to condensed moisture containing sulfur dioxide. 1.2 The exposure conditions may be varied to suit particular requirements and this practice includes provisions for use of different concentrations of sulfur dioxide and for tests either running continuously or in cycles of alternate exposure to the sulfur dioxide containing atmosphere and to the ambient atmosphere. 1.3 The variant of the test to be used, the exposure period required, the type of test specimen, and the criteria of failure are not prescribed by this practice. Such details are provided in appropriate material and product purchase specifications. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety c...

  19. The Analysis of the Psychological Tests Using In Educational Institutions According To the Testing Standards

    Directory of Open Access Journals (Sweden)

    Ezgi MOR DİRLİK

    2017-12-01

    Full Text Available The purpose of this research is to analyze four psychological tests which are frequently used in the Guidance and Research Centers and in the guidance services of the schools according to the standards for educational and psychological testing of APA (American Psychological Association and test adaption standards of ITC (International Testing Commission. The tests were determined based on the goal- oriented sample selecting method and were selected from the most frequently used psychological tests in Guidance and Research Centers and school’s guidance centers. These tests are: Scale of Academic Self-Concept (Akademik Benlik Kavramı Ölçeği-ABKÖ, Evaluation of Early Childhood Development Tool (Gazi Erken Çocukluk Gelişimi Değerlendirme Aracı-GEÇDA, Primary Mental Abilities 7-11 (TKT 7-11, and Wechsler Intelligence Scale for Children Revised Form (WISC-R. In this research, the chapters related to the validity, reliability and test development and revision of “Standards For Educational And Psychological Testing” (APA, 1999 and the adaptation standards developed by ITC were translated into Turkish and a checklist was created by using these documents. The checklist has got two forms as short and long form. The tests were analyzed according to the short form of the checklist by researcher. In order to examine the reliability of these analyses, the analyses were repeated in three weeks’ time. Data of these analyses were exported to the Statistical Package for Social Sciences (SPSS 20.0 and descriptive analysis was perfomed. As a result of this research, the meeting levels of the psychological tests to the test standards in the checklist and the features of the tests which should be improved according to the validity, reliability, test development and revision and test adaptation were determined. In conclusion, the standards analyzed have not been met satisfactorily by ABKÖ and GEÇDA, and according to the analyses of the realibility

  20. Standard error of rating process in knowledge tests

    Directory of Open Access Journals (Sweden)

    Gašper Cankar

    2004-09-01

    Full Text Available Whenever tests are used for making decisions (so-called 'high-stake' tests, different aspects of reliability always become important. If tests are composed of complex items scored by human raters, measurement error increases due to raters' subjectivity. Error variance due to subjectivity of rating process can be estimated through means of generalizability theory which sometimes demand substantial computational strain. Square root of error variance due to subjectivity of rating process is called standard error of rating process (SNOP. The author suggests an alternate computational approach in the special case of two raters for each subject which is faster and easier to compute and should therefore facilitate the use of proposed statistic. Computation of SNOP is shown identical by both approaches on simulated data. The use and interpretation are illustrated by examples of Slovene Matura exams.

  1. The Standard-Model Extension and Gravitational Tests

    CERN Document Server

    Tasson, Jay D

    2016-01-01

    The Standard-Model Extension (SME) provides a comprehensive effective field-theory framework for the study of CPT and Lorentz symmetry. This work reviews the structure and philosophy of the SME and provides some intuitive examples of symmetry violation. The results of recent gravitational tests performed within the SME are summarized including analysis of results from the Laser Interferometer Gravitational-Wave Observatory (LIGO), sensitivities achieved in short-range gravity experiments, constraints from cosmic-ray data, and results achieved by studying planetary ephemerids. Some proposals and ongoing efforts will also be considered including gravimeter tests, tests of the Weak Equivalence Principle, and antimatter experiments. Our review of the above topics is augmented by several original extensions of the relevant work. We present new examples of symmetry violation in the SME and use the cosmic-ray analysis to place first-ever constraints on 81 additional operators.

  2. Rare B decays as tests of the Standard Model

    Science.gov (United States)

    Blake, Thomas; Lanfranchi, Gaia; Straub, David M.

    2017-01-01

    One of the most interesting puzzles in particle physics today is that new physics is expected at the TeV energy scale to solve the hierarchy problem, and stabilises the Higgs mass, but so far no unambiguous signal of new physics has been found. Strong constraints on the energy scale of new physics can be derived from precision tests of the electroweak theory and from flavour-changing or CP-violating processes in strange, charm and beauty hadron decays. Decays that proceed via flavour-changing-neutral-current processes are forbidden at the lowest perturbative order in the Standard Model and are, therefore, rare. Rare b hadron decays are playing a central role in the understanding of the underlying patterns of Standard Model physics and in setting up new directions in model building for new physics contributions. In this article the status and prospects of this field are reviewed.

  3. Testing Conformance to Standards: Notes on the OGC CITE Initiative

    Science.gov (United States)

    Bigagli, Lorenzo; Vitale, Fabrizio

    2010-05-01

    In this work, we report on the issues and lessons learnt from our recent experience on assessing service compliance to OGC geospatial standards. Official conformity is warranted by the OGC Compliance & Interoperability Testing & Evaluation (CITE) initiative, through a centrally managed repository of tests, typically developed via initiatives funded by external sponsors. In particular, we have been involved in the ESA-led Heterogeneous Missions Accessibility Testbed (HMA-T) project. HMA-T objectives included the definition of specifications (and related compliance tests) for Earth Observation (EO) Product discovery and access. Our activities have focused on the EO and Catalogue of ISO Metadata (CIM) Extension Packages (EPs) of the ebRIM Application Profile (AP) of the Catalogue Service for the Web (CSW) OGC standard. Our main contributions have regarded the definition of Abstract Test Suites (ATS's) for the above specifications, as well as the development of Reference Implementations (RIs) and concrete Executable Test Suites (ETS's). According to the state-of-the-art, we have implemented the ETS's in Compliance Test Language (CTL), an OGC standard dialect of XML, and deployed the scripts onto the open-source Test Evaluation And Measurement (TEAM) Engine, the official OGC compliance test platform. A significant challenge was to accommodate legacy services, that can not support data publishing. Hence, we could not assume the presence of control test data, necessary for exhaustive assessment. To cope with this, we have proposed and experimented tests for assessing the internal coherence of a target service instance. Another issue was to assess the overall behavior of a target service instance. Although quite obvious, this requirement proved to be hard (if unviable) to implement, since the design of the OGC catalogue specification is multi-layered (i.e. comprised of EP, AP, binding and core functionalities) and, according to the current OGC rationale, ATS/ETS at each

  4. Standard practice for torque calibration of testing machines and devices

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This practice covers procedures and requirements for the calibration of torque for static and quasi-static torque capable testing machines or devices. These may, or may not, have torque indicating systems and include those devices used for the calibration of hand torque tools. Testing machines may be calibrated by one of the three following methods or combination thereof: 1.1.1 Use of standard weights and lever arms. 1.1.2 Use of elastic torque measuring devices. 1.1.3 Use of elastic force measuring devices and lever arms. 1.1.4 Any of the methods require a specific uncertainty of measurement and a traceability derived from national standards of mass and length. 1.2 The procedures of 1.1.1, 1.1.2, and 1.1.3 apply to the calibration of the torque-indicating systems associated with the testing machine, such as a scale, dial, marked or unmarked recorder chart, digital display, etc. In all cases the buyer/owner/user must designate the torque-indicating system(s) to be calibrated and included in the repor...

  5. Towards a standardized reference point indentation testing procedure.

    Science.gov (United States)

    Setters, Alexander; Jasiuk, Iwona

    2014-06-01

    We study the reference point indentation (RPI) technique which has a potential to directly measure mechanical properties of bone in patients. More specifically, we tested 6 month swine femoral cortical bone at mid-diaphysis region to investigate the effect of several testing variables on the RPI outputs. They include the force magnitude, preconditioning, variation within a sample and between samples, number of cycles, indentation surface (transverse versus longitudinal, polished versus unpolished), and micro-computed tomography radiation exposure. The force magnitude variation test shows that all RPI parameters increase linearly with the increasing force magnitude except the indentation distance increase which shows a cubic trend with a plateau for force magnitudes between 4N and 8N. Preconditioning does not affect the trends for a force magnitude variation test. The cycle variation test shows that most RPI parameters reach either a maximum or minimum at 15-20 cycles. Transverse surface measurements are more consistent than the longitudinal surface measurements, but a rough surface and periosteum on the longitudinal surface could account for this difference. Exposure to the micro-computed tomography radiation in general does not have effect on the RPI measurements. For the 6 month swine femoral cortical bone, testing using 6N force and 20 cycles with preconditioning on an unpolished longitudinal surface is recommended. This study advances our knowledge on how the RPI testing variables influence the RPI outputs and provides guidance on the RPI measurements. It may also serve as a framework for developing a standardized testing procedure for the RPI technique. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Key challenges for nanotechnology: Standardization of ecotoxicity testing.

    Science.gov (United States)

    Cerrillo, Cristina; Barandika, Gotzone; Igartua, Amaya; Areitioaurtena, Olatz; Mendoza, Gemma

    2017-04-03

    Nanotechnology is expected to contribute to the protection of the environment, but many uncertainties exist regarding the environmental and human implications of manufactured nanomaterials (MNMs). Contradictory results have been reported for their ecotoxicity to aquatic organisms, which constitute one of the most important pathways for their entrance and transfer throughout the food web. The present review is focused on the international strategies that are laying the foundations of the ecotoxicological assessment of MNMs. Specific advice is provided on the preparation of MNM dispersions in the culture media of the organisms, which is considered a key factor to overcome the limitations in the standardization of the test methodologies.

  7. Standard test method for measuring pH of soil for use in corrosion testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1995-01-01

    1.1 This test method covers a procedure for determining the pH of a soil in corrosion testing. The principle use of the test is to supplement soil resistivity measurements and thereby identify conditions under which the corrosion of metals in soil may be accentuated (see G 57 - 78 (1984)). 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  8. Standard Test Method for Tension and Vacuum Testing Metallized Ceramic Seals

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers procedures for conducting tension and vacuum tests on metal-ceramic seals to determine the bond strength of brazed, metallized ceramics. This test method is not to be considered as an absolute tension test for the ceramic. 1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Standard Specification for Solar Simulation for Terrestrial Photovoltaic Testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This specification provides means for classifying solar simulators intended for indoor testing of photovoltaic devices (solar cells or modules), according to their spectral match to a reference spectral irradiance, non-uniformity of spatial irradiance, and temporal instability of irradiance. 1.2 Testing of photovoltaic devices may require the use of solar simulators. Test Methods that require specific classification of simulators as defined in this specification include Test Methods E948, E1036, and E1362. 1.3 This standard is applicable to both pulsed and steady state simulators and includes recommended test requirements used for classifying such simulators. 1.4 A solar simulator usually consists of three major components: (1) light source(s) and associated power supply; (2) any optics and filters required to modify the output beam to meet the classification requirements in Section 4; and (3) the necessary controls to operate the simulator, adjust irradiance, etc. 1.5 A light source that does not mee...

  10. Standard test methods for notched bar impact testing of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 These test methods describe notched-bar impact testing of metallic materials by the Charpy (simple-beam) test and the Izod (cantilever-beam) test. They give the requirements for: test specimens, test procedures, test reports, test machines (see Annex A1) verifying Charpy impact machines (see Annex A2), optional test specimen configurations (see Annex A3), precracking Charpy V-notch specimens (see Annex A4), designation of test specimen orientation (see Annex A5), and determining the percent of shear fracture on the surface of broken impact specimens (see Annex A6). In addition, information is provided on the significance of notched-bar impact testing (see Appendix X2), methods of measuring the center of strike (see Appendix X2). 1.2 These test methods do not address the problems associated with impact testing at temperatures below -196 C (-320 F, 77 K). 1.3 The values stated in SI units are to be regarded as the standard. Inch-pound units are provided for information only. This standard does not purpor...

  11. Stress-testing the Standard Model at the LHC

    CERN Document Server

    2016-01-01

    With the high-energy run of the LHC now underway, and clear manifestations of beyond-Standard-Model physics not yet seen in data from the previous run, the search for new physics at the LHC may be a quest for small deviations with big consequences. If clear signals are present, precise predictions and measurements will again be crucial for extracting the maximum information from the data, as in the case of the Higgs boson. Precision will therefore remain a key theme for particle physics research in the coming years. The conference will provide a forum for experimentalists and theorists to identify the challenges and refine the tools for high-precision tests of the Standard Model and searches for signals of new physics at Run II of the LHC. Topics to be discussed include: pinning down Standard Model corrections to key LHC processes; combining fixed-order QCD calculations with all-order resummations and parton showers; new developments in jet physics concerning jet substructure, associated jets and boosted je...

  12. Standardized childhood fitness percentiles derived from school-based testing.

    Science.gov (United States)

    Carrel, Aaron L; Bowser, John; White, Doug; Moberg, D Paul; Weaver, Brian; Hisgen, Jon; Eickhoff, Jens; Allen, David B

    2012-07-01

    To develop a statewide school-based program of measuring and reporting cardiovascular fitness levels in children, and to create age- and sex-specific cardiovascular fitness percentile-based distribution curves. A pilot study validated cardiovascular fitness assessment with Progressive Aerobic Cardiovascular Endurance Run (PACER) testing as an accurate predictor of cardiovascular fitness measured by maximal oxygen consumption treadmill testing. Schools throughout the state were then recruited to perform PACER and body mass index (BMI) measurement and report de-identified data to a centralized database. Data on 20 631 individual students with a mean age 12.1 ± 2.0 years, BMI of 21.4 ± 5.1, and a cardiovascular fitness measured with PACER of 29.7 ± 18.2 laps (estimated maximal oxygen consumption of 36.5 mL/kg/min) were submitted for analysis. Standardized fitness percentiles were calculated for age and sex. This study demonstrates the feasibility of performing, reporting, and recording annual school-based assessments of cardiovascular fitness to develop standardized childhood fitness percentiles on the basis of age and sex. Such data can be useful in comparing populations and assessing initiatives that aim to improve childhood fitness. Because health consequences of obesity result from both adiposity and physical inactivity, supplementation of BMI measurement with tracking of cardiovascular fitness adds a valuable tool for large-scale health assessment. Published by Mosby, Inc.

  13. Standard test method for wear testing with a pin-on-disk apparatus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers a laboratory procedure for determining the wear of materials during sliding using a pin-on-disk apparatus. Materials are tested in pairs under nominally non-abrasive conditions. The principal areas of experimental attention in using this type of apparatus to measure wear are described. The coefficient of friction may also be determined. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. BSAC standardized disc susceptibility testing method (version 10).

    Science.gov (United States)

    Andrews, J M; Howe, R A

    2011-12-01

    The BSAC standardized disc susceptibility testing method remains unchanged, but there are considerable changes to the interpretative criteria due to continuing harmonization with the European Committee on Antimicrobial Susceptibility Testing (EUCAST) MIC breakpoints. There are a number of agents for which interpretative criteria have been removed. These MIC and/or zone diameter breakpoints will be published on the BSAC web site as a 'Legacy' table; they may be used for research or comparative purposes, but are not recommended for clinical management. Notably, testing of staphylococci for susceptibility to glycopeptides by disc diffusion has been removed because this method has been found to be unreliable, particularly for the detection of low-level resistance; low-level vancomycin resistance in staphylococci is increasingly deemed to be of clinical relevance. The tables for anaerobes have been expanded to include MIC breakpoints that have been determined by EUCAST. There are currently no zone diameter breakpoints for these organisms and an MIC method is recommended if susceptibility testing is required.

  15. Aligning English grammar testing with European language standards

    Directory of Open Access Journals (Sweden)

    Bodrič Radmila

    2015-01-01

    Full Text Available In recent years, foreign language testing has gained in significance with the advent of The Common European Framework of Reference for Languages (2001 (CEFR, a European language document which set comparable standards for learning, teaching and assessing foreign languages. The CEFR was used to set the research aim of this paper - testing grammar at level B2. The main aim of the research was to determine grammatical competence at level B2 and additional aims included: (a determining which particular areas of grammar need to be learned by students at level B2, (b formulating grammatical descriptors for each individual area of grammar, (c determining the test’s threshold level which would fulfil the criteria for grammatical competence at level B2, and (d determining the extent to which students have mastered the given areas. The pre-testing was followed by the main testing on the sample of 164 students in two secondary schools. The results indicated that the quantity and quality of grammatical competence was lower than expected: 47% of the population failed to fulfil the basic level of grammatical competence. The causes may be attributed to the factors of a subjective and objective nature. Level B2 is demanding qualitatively as well as quantitatively, regarding both the formal and the functional complexity and scope of language use, which requires intensive language production, high levels of motivation and sound working habits in order to master the given grammatical structures.

  16. Standard Test Method for Preparing Aircraft Cleaning Compounds, Liquid Type, Water Base, for Storage Stability Testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the stability in storage, of liquid, water-base chemical cleaning compounds, used to clean the exterior surfaces of aircraft. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  17. Standard Test Method for Hydrophobic Surface Films by the Water-Break Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the detection of the presence of hydrophobic (nonwetting) films on surfaces and the presence of hydrophobic organic materials in processing ambients. When properly conducted, the test will enable detection of molecular layers of hydrophobic organic contaminants. On very rough or porous surfaces, the sensitivity of the test may be significantly decreased. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  18. Standard test method for conducting wet sand/rubber wheel abrasion tests

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers laboratory procedures for determining the resistance of metallic materials to scratching abrasion by means of the wet sand/rubber wheel test. It is the intent of this procedure to provide data that will reproducibly rank materials in their resistance to scratching abrasion under a specified set of conditions. 1.2 Abrasion test results are reported as volume loss in cubic millimeters. Materials of higher abrasion resistance will have a lower volume loss. 1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Standard Test Method for Hydrophobic Surface Films by the Atomizer Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1965-01-01

    1.1 This test method covers the detection of the presence of hydrophobic (nonwetting) films on surfaces and the presence of hydrophobic organic materials in processing ambients. When properly conducted, the test will enable detection of fractional molecular layers of hydrophobic organic contaminants. On very rough or porous surfaces the sensitivity of the test may be significantly decreased. 1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  20. Standard test method for guided bend test for ductility of welds

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers a guided bend test for the determination of soundness and ductility of welds in ferrous and nonferrous products. Defects, not shown by X rays, may appear in the surface of a specimen when it is subjected to progressive localized overstressing. This guided bend test has been developed primarily for plates and is not intended to be substituted for other methods of bend testing. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. Note 1—For additional information see Terminology E 6, and American Welding Society Standard D 1.1. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  1. Test surfaces useful for calibration of surface profilometers

    Science.gov (United States)

    Yashchuk, Valeriy V; McKinney, Wayne R; Takacs, Peter Z

    2013-12-31

    The present invention provides for test surfaces and methods for calibration of surface profilometers, including interferometric and atomic force microscopes. Calibration is performed using a specially designed test surface, or the Binary Pseudo-random (BPR) grating (array). Utilizing the BPR grating (array) to measure the power spectral density (PSD) spectrum, the profilometer is calibrated by determining the instrumental modulation transfer.

  2. Standard test method for K-R curve determination

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of the resistance to fracture of metallic materials under Mode I loading at static rates using either of the following notched and precracked specimens: the middle-cracked tension M(T) specimen or the compact tension C(T) specimen. A K-R curve is a continuous record of toughness development (resistance to crack extension) in terms of KR plotted against crack extension in the specimen as a crack is driven under an increasing stress intensity factor, K. 1.2 Materials that can be tested for K-R curve development are not limited by strength, thickness, or toughness, so long as specimens are of sufficient size to remain predominantly elastic to the effective crack extension value of interest. 1.3 Specimens of standard proportions are required, but size is variable, to be adjusted for yield strength and toughness of the materials. 1.4 Only two of the many possible specimen types that could be used to develop K-R curves are covered in this method. 1.5 The test is app...

  3. Working on a Standard Joint Unit: A pilot test.

    Science.gov (United States)

    Casajuana, Cristina; López-Pelayo, Hugo; Mercedes Balcells, María; Miquel, Laia; Teixidó, Lídia; Colom, Joan; Gual, Antoni

    2017-09-29

    Assessing cannabis consumption remains complex due to no reliable registration systems. We tested the likelihood of establishing a Standard Joint Unit (SJU) which considers the main cannabinoids with implication on health through a naturalistic approach.  Methodology. Pilot study with current cannabis users of four areas of Barcelona: universities, nightclubs, out-patient mental health service, and cannabis associations. We designed and administered a questionnaire on cannabis use-patterns and determined the willingness to donate a joint for analysis. Descriptive statistics were used to analyze the data. Forty volunteers answered the questionnaire (response rate 95%); most of them were men (72.5%) and young adults (median age 24.5 years; IQR 8.75 years) who consume daily or nearly daily (70%). Most participants consume marihuana (85%) and roll their joints with a median of 0.25 gr of marihuana. Two out of three (67.5%) stated they were willing to donate a joint. Obtaining an SJU with the planned methodology has proved to be feasible. Pre-testing resulted in an improvement of the questionnaire and retribution to incentivize donations. Establishing an SJU is essential to improve our knowledge on cannabis-related outcomes.

  4. Development of the Test Of Astronomy STandards (TOAST) Assessment Instrument

    Science.gov (United States)

    Slater, Timothy F.; Slater, S. J.

    2008-05-01

    Considerable effort in the astronomy education research (AER) community over the past several years has focused on developing assessment tools in the form of multiple-choice conceptual diagnostics and content knowledge surveys. This has been critically important in advancing the AER discipline so that researchers could establish the initial knowledge state of students as well as to attempt measure some of the impacts of innovative instructional interventions. Unfortunately, few of the existing instruments were constructed upon a solid list of clearly articulated and widely agreed upon learning objectives. This was not done in oversight, but rather as a result of the relative youth of AER as a discipline. Now that several important science education reform documents exist and are generally accepted by the AER community, we are in a position to develop, validate, and disseminate a new assessment instrument which is tightly aligned to the consensus learning goals stated by the American Astronomical Society - Chair's Conference on ASTRO 101, the American Association of the Advancement of Science's Project 2061 Benchmarks, and the National Research Council's National Science Education Standards. In response, researchers from the Cognition in Astronomy, Physics and Earth sciences Research (CAPER) Team at the University of Wyoming's Science & Math Teaching Center (UWYO SMTC) have designed a criterion-referenced assessment tool, called the Test Of Astronomy STandards (TOAST). Through iterative development, this instrument has a high degree of reliability and validity for instructors and researchers needing information on students’ initial knowledge state at the beginning of a course and can be used, in aggregate, to help measure the impact of course-length duration instructional strategies for courses with learning goals tightly aligned to the consensus goals of our community.

  5. Standards for thyroid laboratory testing, and cognitive functions after menopause

    Directory of Open Access Journals (Sweden)

    Iwona Bojar

    2014-09-01

    Full Text Available Introduction : The aim of the study is to analyze the relationship between normative and non-normative thyroid tests (TSH, TT4, TT3, FT3, FT4, anti-TPO, anti-Tg, AB-TSHR and the level of cognitive functions in postmenopausal women. Material and methods: The study group consisted of 383 women from south-eastern Poland, aged 50-65 years. The cognitive functions were evaluated using a diagnostic instrument – Central Nervous System – Vital Signs (CNS-VS. Blood was collected for determination of the following parameters: TSH, TT4, TT3, FT3, FT4, anti-TPO, anti-Tg, AB-TSHR. Results: There were significant differences in NCI, executive functions, psychomotor speed, reaction time, complex attention and cognitive flexibility, depending on the normative and non-normative level of TSH. Women whose level of FT3 was at the lower limit of the normal range obtained poorer results in psychomotor speed, while subjects with levels of FT4 below the standard achieved significantly lower scores for this function. The relationship between NCI and cognitive functions, and the normative and non-normative anti-TPO results, showed significant differences in verbal memory, visual memory, processing speed and reaction time. The level of AB-TSHR reported as normal or above the norm significantly differentiated from the results of NCI, processing speed, executive functions, psychomotor speed, complex attention and cognitive flexibility. Conclusions : Concentrations of laboratory parameters assessing the thyroid function located within the upper limits of the normal range showed a different relationship with the cognitive performance than concentrations located within the lower limits of the standard.

  6. Refractory Metal Heat Pipe Life Test - Test Plan and Standard Operating Procedures

    Science.gov (United States)

    Martin, J. J.; Reid, R. S.

    2010-01-01

    Refractory metal heat pipes developed during this project shall be subjected to various operating conditions to evaluate life-limiting corrosion factors. To accomplish this objective, various parameters shall be investigated, including the effect of temperature and mass fluence on long-term corrosion rate. The test series will begin with a performance test of one module to evaluate its performance and to establish the temperature and power settings for the remaining modules. The performance test will be followed by round-the-clock testing of 16 heat pipes. All heat pipes shall be nondestructively inspected at 6-month intervals. At longer intervals, specific modules will be destructively evaluated. Both the nondestructive and destructive evaluations shall be coordinated with Los Alamos National Laboratory. During the processing, setup, and testing of the heat pipes, standard operating procedures shall be developed. Initial procedures are listed here and, as hardware is developed, will be updated, incorporating findings and lessons learned.

  7. Standardized Testing Program for Solid-State Hydrogen Storage Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Michael A. [Southwest Research Institute; Page, Richard A. [Southwest Research Institute

    2012-07-30

    In the US and abroad, major research and development initiatives toward establishing a hydrogen-based transportation infrastructure have been undertaken, encompassing key technological challenges in hydrogen production and delivery, fuel cells, and hydrogen storage. However, the principal obstacle to the implementation of a safe, low-pressure hydrogen fueling system for fuel-cell powered vehicles remains storage under conditions of near-ambient temperature and moderate pressure. The choices for viable hydrogen storage systems at the present time are limited to compressed gas storage tanks, cryogenic liquid hydrogen storage tanks, chemical hydrogen storage, and hydrogen absorbed or adsorbed in a solid-state material (a.k.a. solid-state storage). Solid-state hydrogen storage may offer overriding benefits in terms of storage capacity, kinetics and, most importantly, safety.The fervor among the research community to develop novel storage materials had, in many instances, the unfortunate consequence of making erroneous, if not wild, claims on the reported storage capacities achievable in such materials, to the extent that the potential viability of emerging materials was difficult to assess. This problem led to a widespread need to establish a capability to accurately and independently assess the storage behavior of a wide array of different classes of solid-state storage materials, employing qualified methods, thus allowing development efforts to focus on those materials that showed the most promise. However, standard guidelines, dedicated facilities, or certification programs specifically aimed at testing and assessing the performance, safety, and life cycle of these emergent materials had not been established. To address the stated need, the Testing Laboratory for Solid-State Hydrogen Storage Technologies was commissioned as a national-level focal point for evaluating new materials emerging from the designated Materials Centers of Excellence (MCoE) according to

  8. Commercial Pilot Practical Test Standards for Lighter-Than-Air Balloon, Airship

    Science.gov (United States)

    1997-05-01

    The Commercial Pilot Lighter-Than-Air Practical Test Standards (PTS) book has been published by the Federal Aviation Administration (FAA) to establish the standards for commercial pilot certification practical tests for the lighter-than-air category,...

  9. Private Pilot Practical Test Standards for Lighter-Than-Air Balloon, Airship

    Science.gov (United States)

    1996-06-01

    The Private Pilot - Lighter-Than-Air (Balloon and Airship) Practical Test Standards (PTS) book has been published by the Federal Aviation Administration (FAA) to establish the standards for private pilot certification practical tests for the lighter-...

  10. Standard test method for measuring waste glass or glass ceramic durability by vapor hydration test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 The vapor hydration test method can be used to study the corrosion of a waste forms such as glasses and glass ceramics upon exposure to water vapor at elevated temperatures. In addition, the alteration phases that form can be used as indicators of those phases that may form under repository conditions. These tests; which allow altering of glass at high surface area to solution volume ratio; provide useful information regarding the alteration phases that are formed, the disposition of radioactive and hazardous components, and the alteration kinetics under the specific test conditions. This information may be used in performance assessment (McGrail et al, 2002 (1) for example). 1.2 This test method must be performed in accordance with all quality assurance requirements for acceptance of the data. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practice...

  11. Standard Test Method for Oxyacetylene Ablation Testing of Thermal Insulation Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the screening of ablative materials to determine the relative thermal insulation effectiveness when tested as a flat panel in an environment of a steady flow of hot gas provided by an oxyacetylene burner. 1.2 This test method should be used to measure and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard of materials, products, or assemblies under actual fire conditions. However, results of this test method may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limi...

  12. Design of Long Period Pseudo-Random Sequences from the Addition of m -Sequences over 𝔽 p

    OpenAIRE

    Ren Jian

    2004-01-01

    Pseudo-random sequence with good correlation property and large linear span is widely used in code division multiple access (CDMA) communication systems and cryptology for reliable and secure information transmission. In this paper, sequences with long period, large complexity, balance statistics, and low cross-correlation property are constructed from the addition of m -sequences with pairwise-prime linear spans (AMPLS). Using m -sequences as building blocks, the proposed method proved to...

  13. Standardized methods for in-place filter testing

    Energy Technology Data Exchange (ETDEWEB)

    Dykes, M.; Fretthold, J.K.; Slawski, J.

    1997-08-01

    The conference minutes of a US DOE meeting held on in-place filter testing are presented. The purpose of the conference was to transfer technical in-place testing knowledge throughout the DOE complex. Major items discussed included purchase requisitions, in-place testing, instrumentation, and in-place test personnel qualifications and training. Future actions identified by conference attendees centered on establishing complex-wide DOE policies on training, inspection and testing, and filter specifications.

  14. Tests of the standard electroweak model in beta decay

    CERN Document Server

    Severijns, N; Naviliat-Cuncic, O

    2006-01-01

    We review the current status of precision measurements in allowed nuclear beta decay, including neutron decay, with emphasis on their potential to look for new physics beyond the standard electroweak model. The experimental results are interpreted in the framework of phenomenological model-independent descriptions of nuclear beta decay as well as in some specific extensions of the standard model. The values of the standard couplings and the constraints on the exotic couplings of the general beta decay Hamiltonian are updated. For the ratio between the axial and the vector couplings we obtain C_A/C_V = -1.26992(69) under the standard model assumptions. Particular attention is devoted to the discussion of the sensitivity and complementarity of different precision experiments in direct beta decay. The prospects and the impact of recent developments of precision tools and of high intensity low energy beams are also addressed.

  15. Tests of the standard electroweak model in beta decay

    Energy Technology Data Exchange (ETDEWEB)

    Severijns, N.; Beck, M. [Universite Catholique de Louvain (UCL), Louvain-la-Neuve (Belgium); Naviliat-Cuncic, O. [Caen Univ., CNRS-ENSI, 14 (France). Lab. de Physique Corpusculaire

    2006-05-15

    We review the current status of precision measurements in allowed nuclear beta decay, including neutron decay, with emphasis on their potential to look for new physics beyond the standard electroweak model. The experimental results are interpreted in the framework of phenomenological model-independent descriptions of nuclear beta decay as well as in some specific extensions of the standard model. The values of the standard couplings and the constraints on the exotic couplings of the general beta decay Hamiltonian are updated. For the ratio between the axial and the vector couplings we obtain C{sub A},/C{sub V} = -1.26992(69) under the standard model assumptions. Particular attention is devoted to the discussion of the sensitivity and complementarity of different precision experiments in direct beta decay. The prospects and the impact of recent developments of precision tools and of high intensity low energy beams are also addressed. (author)

  16. Framework for a Comparative Accelerated Testing Standard for PV Modules: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, S.; Wohlgemuth, J.; Yamamichi, M.; Sample, T.; Miller, D.; Meakin, D.; Monokroussos, C.; TamizhMani, M.; Kempe, M.; Jordan, D.; Bosco, N.; Hacke, P.; Bermudez, V.; Kondo, M.

    2013-08-01

    As the photovoltaic industry has grown, the interest in comparative accelerated testing has also grown. Private test labs offer testing services that apply greater stress than the standard qualification tests as tools for differentiating products and for gaining increased confidence in long-term PV investments. While the value of a single international standard for comparative accelerated testing is widely acknowledged, the development of a consensus is difficult. This paper strives to identify a technical basis for a comparative standard.

  17. What are standardized literacy and numeracy tests testing? Evidence of the domain-general contributions to students' standardized educational test performance.

    Science.gov (United States)

    Howard, Steven J; Woodcock, Stuart; Ehrich, John; Bokosmaty, Sahar

    2017-03-01

    A fundamental aim of standardized educational assessment is to achieve reliable discrimination between students differing in the knowledge, skills and abilities assessed. However, questions of the purity with which these tests index students' genuine abilities have arisen. Specifically, literacy and numeracy assessments may also engage unintentionally assessed capacities. The current study investigated the extent to which domain-general processes - working memory (WM) and non-verbal reasoning - contribute to students' standardized test performance and the pathway(s) through which they exert this influence. Participants were 91 Grade 2 students recruited from five regional and metropolitan primary schools in Australia. Participants completed measures of WM and non-verbal reasoning, as well as literacy and numeracy subtests of a national standardized educational assessment. Path analysis of Rasch-derived ability estimates and residuals with domain-general cognitive abilities indicated: (1) a consistent indirect pathway from WM to literacy and numeracy ability, through non-verbal reasoning; (2) direct paths from phonological WM and literacy ability to numeracy ability estimates; and (3) a direct path from WM to spelling test residuals. Results suggest that the constitution of this nationwide standardized assessment confounded non-targeted abilities with those that were the target of assessment. This appears to extend beyond the effect of WM on learning more generally, to the demands of different assessment types and methods. This has implications for students' abilities to demonstrate genuine competency in assessed areas and the educational supports and provisions they are provided on the basis of these results. © 2016 The British Psychological Society.

  18. Standard test method for isotopic analysis of uranium hexafluoride by double standard single-collector gas mass spectrometer method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This is a quantitative test method applicable to determining the mass percent of uranium isotopes in uranium hexafluoride (UF6) samples with 235U concentrations between 0.1 and 5.0 mass %. 1.2 This test method may be applicable for the entire range of 235U concentrations for which adequate standards are available. 1.3 This test method is for analysis by a gas magnetic sector mass spectrometer with a single collector using interpolation to determine the isotopic concentration of an unknown sample between two characterized UF6 standards. 1.4 This test method is to replace the existing test method currently published in Test Methods C761 and is used in the nuclear fuel cycle for UF6 isotopic analyses. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro...

  19. Standardization for Large Deflection Rotating-bending Fatigue Testing Method

    National Research Council Canada - National Science Library

    Reseach Committee on Standardizatio

    1996-01-01

    ... testing method has not been established. Consideing these background, actural problems of the conventional method were investigated, and load-controlled method and deflection-controlled method were tested in order to compare the scattering...

  20. Gold Standard Testing of Motion Based Tracking Systems

    Science.gov (United States)

    2017-03-15

    shoulder Each athlete was also wearing a Catapult 4.0 TESTING PROTOCOL The testing team mapped out 2 ‘team’ runs, and 4 different field routes...timed rest 30 seconds was led by the field testing lead, and the run was repeated back to the starting point. 88ABW-2017-1670, 17 April 2017 Figure

  1. Standardization of food allergen extracts for skin prick test

    DEFF Research Database (Denmark)

    Skamstrup Hansen, K; Bindslev-Jensen, C; Skov, P S

    2001-01-01

    -blind, placebo-controlled food challenge, except for the hazelnut-allergic patients. The controls were subjected to an open food challenge with all the foods to ensure tolerance. The standardization was performed by means of titrated SPT in accordance with the guidelines on biological standardization from...... investigated by leukocyte histamine release (HR) and immunoblotting experiments using sera from 27 hazelnut allergic patients. The clinical sensitivity of the optimized hazelnut extract evaluated by HR was 0.78 compared to 0.30 for a commercially available hazelnut extract (Soluprick). Immunoblotting results...

  2. [The electromagnetic compatibility test requirements for cardiac pacemaker in international standards].

    Science.gov (United States)

    Liu, Lei; Gao, Zhong

    2010-09-01

    Based on the latest international standards about implantable pacemakers, describing the main test requirements, especially for the EMC test requirements in details, and comparing the differences between the different standards, making readers having a clear understanding for the tests on pacemakers, especially for the EMC tests.

  3. 40 CFR 85.2207 - On-board diagnostics test standards.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false On-board diagnostics test standards... Warranty Short Tests § 85.2207 On-board diagnostics test standards. (a) (b) A vehicle shall fail the on-board diagnostics test if it is a 1996 or newer vehicle and the vehicle connector is missing, has been...

  4. 42 CFR 493.1489 - Standard; Testing personnel qualifications.

    Science.gov (United States)

    2010-10-01

    ... HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Personnel for Nonwaived... biology; and (iii) Twelve semester hours of chemistry, biology, or medical laboratory technology in any... analysis— (i) Be qualified under § 493.1489(b)(1), (b)(2), (b)(3), (b)(4), or (b)(5); (ii) Have earned a...

  5. New ASTM Standards for Nondestructive Testing of Aerospace Composites

    Science.gov (United States)

    Waller, Jess M.; Saulsberry, Regor L.

    2010-01-01

    Problem: Lack of consensus standards containing procedural detail for NDE of polymer matrix composite materials: I. Flat panel composites. II. Composite components with more complex geometries a) Pressure vessels: 1) composite overwrapped pressure vessels (COPVs). 2) composite pressure vessels (CPVs). III. Sandwich core constructions. Metal and brittle matrix composites are a possible subject of future effort.

  6. Cognitive fatigue influences students' performance on standardized tests.

    Science.gov (United States)

    Sievertsen, Hans Henrik; Gino, Francesca; Piovesan, Marco

    2016-03-08

    Using test data for all children attending Danish public schools between school years 2009/10 and 2012/13, we examine how the time of the test affects performance. Test time is determined by the weekly class schedule and computer availability at the school. We find that, for every hour later in the day, test performance decreases by 0.9% of an SD (95% CI, 0.7-1.0%). However, a 20- to 30-minute break improves average test performance by 1.7% of an SD (95% CI, 1.2-2.2%). These findings have two important policy implications: First, cognitive fatigue should be taken into consideration when deciding on the length of the school day and the frequency and duration of breaks throughout the day. Second, school accountability systems should control for the influence of external factors on test scores.

  7. Airside HVAC BESTEST: HVAC Air-Distribution System Model Test Cases for ASHRAE Standard 140

    Energy Technology Data Exchange (ETDEWEB)

    Judkoff, Ronald [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Neymark, Joel [J. Neymark & Associates; Kennedy, Mike D. [Mike D. Kennedy, Inc.; Gall, J. [AAON, Inc.; Henninger, R. [GARD Analytics, Inc.; Hong, T. [Lawrence Berkeley National Laboratory; Knebel, D. [AAON, Inc.; McDowell, T. [Thermal Energy System Specialists, LLC; Witte, M. [GARD Analytics, Inc.

    2017-08-07

    This paper summarizes recent work to develop new airside HVAC equipment model analytical verification test cases for ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. The analytical verification test method allows comparison of simulation results from a wide variety of building energy simulation programs with quasi-analytical solutions, further described below. Standard 140 is widely cited for evaluating software for use with performance-path energy efficiency analysis, in conjunction with well-known energy-efficiency standards including ASHRAE Standard 90.1, the International Energy Conservation Code, and other international standards. Airside HVAC Equipment is a common area of modelling not previously explicitly tested by Standard 140. Integration of the completed test suite into Standard 140 is in progress.

  8. Standard test methods for arsenic in uranium hexafluoride

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 These test methods are applicable to the determination of total arsenic in uranium hexafluoride (UF6) by atomic absorption spectrometry. Two test methods are given: Test Method A—Arsine Generation-Atomic Absorption (Sections 5-10), and Test Method B—Graphite Furnace Atomic Absorption (Appendix X1). 1.2 The test methods are equivalent. The limit of detection for each test method is 0.1 μg As/g U when using a sample containing 0.5 to 1.0 g U. Test Method B does not have the complete collection details for precision and bias data thus the method appears as an appendix. 1.3 Test Method A covers the measurement of arsenic in uranyl fluoride (UO2F2) solutions by converting arsenic to arsine and measuring the arsine vapor by flame atomic absorption spectrometry. 1.4 Test Method B utilizes a solvent extraction to remove the uranium from the UO2F2 solution prior to measurement of the arsenic by graphite furnace atomic absorption spectrometry. 1.5 Both insoluble and soluble arsenic are measured when UF6 is...

  9. Standard test method for electrochemical critical pitting temperature testing of stainless steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers a procedure for the evaluation of the resistance of stainless steel and related alloys to pitting corrosion based on the concept of the determination of a potential independent critical pitting temperature (CPT). 1.2 This test methods applies to wrought and cast products including but not restricted to plate, sheet, tubing, bar, forgings, and welds, (see Note 1). Note 1—Examples of CPT measurements on sheet, plate, tubing, and welded specimens for various stainless steels can be found in Ref (1). See the research reports (Section 14). 1.3 The standard parameters recommended in this test method are suitable for characterizing the CPT of austenitic stainless steels and other related alloys with a corrosion resistance ranging from that corresponding to solution annealed UNS S31600 (Type 316 stainless steel) to solution annealed UNS S31254 (6 % Mo stainless steel). 1.4 This test method may be extended to stainless steels and other alloys related to stainless steel that have a CPT...

  10. 75 FR 4323 - Additional Quantitative Fit-testing Protocols for the Respiratory Protection Standard

    Science.gov (United States)

    2010-01-27

    ...-testing Protocols for the Respiratory Protection Standard AGENCY: Occupational Safety and Health... among the quantitative fit tests listed in Part II of Appendix A of its Respiratory Protection Standard... . SUPPLEMENTARY INFORMATION: I. Background Appendix A of OSHA's Respiratory Protection Standard at 29 CFR 1010.134...

  11. Conceptualizing Teaching to the Test under Standards-Based Reform

    Science.gov (United States)

    Welsh, Megan E.; Eastwood, Melissa; D'Agostino, Jerome V.

    2014-01-01

    Teacher and school accountability systems based on high-stakes tests are ubiquitous throughout the United States and appear to be growing as a catalyst for reform. As a result, educators have increased the proportion of instructional time devoted to test preparation. Although guidelines for what constitutes appropriate and inappropriate test…

  12. 40 CFR 80.165 - Certification test procedures and standards.

    Science.gov (United States)

    2010-07-01

    ..._locations.html. Copies of this material may be obtained from ASTM, 1916 Race St., Philadelphia, PA 19103. (2... from ASTM, 1916 Race St., Philadelphia, PA 19103. (c) If conducted using test fuels meeting all... Board, “Test Method for Evaluating Port Fuel Injector (PFI) Deposits in Vehicle Engines”, March 1, 1991...

  13. Standardization of incubation conditions for hemolysis testing of biomaterials

    NARCIS (Netherlands)

    Henkelman, Sandra; Rakhorst, Gerhard; Blanton, John; van Oeveren, Willem

    2009-01-01

    Hemolysis testing is the most common method to determine the hemocompatibility properties of biomaterials. There is however no consensus on the procedures of hemolysis testing due to insufficient comparative studies on the quality of the red blood cells used and the experimental conditions of

  14. Developing and Standardization of a Diagnostic Reading Test

    Directory of Open Access Journals (Sweden)

    Tahereh Sima-Shirazi

    2004-06-01

    Full Text Available Objective: This paper is a report on the development, structure and content of a diagnostic dyslexia reading test. The target population of this test is persian children who have problems in learning reading and may be considered as dyslexic. This diagnostic test is the first reading test developed for the native speakers of persian. Materials & Methods: The theoretical framework of the test is based on two well- established reading tests for the English speaking children, namely Durrell Analysis of Reading and Neale Analysis of Reading Ability. The linguistic content of the subtests is selected from the vocabulary and texts of the textbook used in the primary schools. Both the vocabulary and the sentences of the parrallel passeges were controlled for frequency, phonemic/graphemic regularity, syllable structure, morphology, syntax and semantics. They were also controlled for value judgement by two linguistics and three first grader teachers.The first version of the test is normed on 605 boy and girl first graders from different educational sectors and schools selected randomly.The method used in this research is cross- sectional, descriptive- analytic and the data analysis is based on pearson, and mann-whitney u. Results: Reliability of the test is calculated based on parrallel forms (~ 90% and validity is based on content validity.This test has a supplementary section including spelling, graphem/ phoneme correspondness, nonword reading, irregular word reading, and copy subtests. Conclusion: Considering highreliability and precise validation of the test it can be used to diagnose the dyslexia and related linguistic impairments.

  15. The Limitations of Standardized Science Tests as Benchmarks for Artificial Intelligence Research: Position Paper

    OpenAIRE

    Davis, Ernest

    2014-01-01

    In this position paper, I argue that standardized tests for elementary science such as SAT or Regents tests are not very good benchmarks for measuring the progress of artificial intelligence systems in understanding basic science. The primary problem is that these tests are designed to test aspects of knowledge and ability that are challenging for people; the aspects that are challenging for AI systems are very different. In particular, standardized tests do not test knowledge that is obvious...

  16. Standard Test Method for Contamination Outgassing Characteristics of Spacecraft Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers a technique for generating data to characterize the kinetics of the release of outgassing products from materials. This technique will determine both the total mass flux evolved by a material when exposed to a vacuum environment and the deposition of this flux on surfaces held at various specified temperatures. 1.2 This test method describes the test apparatus and related operating procedures for evaluating the total mass flux that is evolved from a material being subjected to temperatures that are between 298 and 398 K. Pressures external to the sample effusion cell are less than 7 × 10−3 Pa (5 × 10−5 torr). Deposition rates are measured during material outgassing tests. A test procedure for collecting data and a test method for processing and presenting the collected data are included. 1.3 This test method can be used to produce the data necessary to support mathematical models used for the prediction of molecular contaminant generation, migration, and deposition. 1.4 Al...

  17. Standard test method for measurement of fatigue crack growth rates

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2015-01-01

    1.1 This test method covers the determination of fatigue crack growth rates from near-threshold to Kmax controlled instability. Results are expressed in terms of the crack-tip stress-intensity factor range (ΔK), defined by the theory of linear elasticity. 1.2 Several different test procedures are provided, the optimum test procedure being primarily dependent on the magnitude of the fatigue crack growth rate to be measured. 1.3 Materials that can be tested by this test method are not limited by thickness or by strength so long as specimens are of sufficient thickness to preclude buckling and of sufficient planar size to remain predominantly elastic during testing. 1.4 A range of specimen sizes with proportional planar dimensions is provided, but size is variable to be adjusted for yield strength and applied force. Specimen thickness may be varied independent of planar size. 1.5 The details of the various specimens and test configurations are shown in Annex A1-Annex A3. Specimen configurations other than t...

  18. Standard Test Methods for Determining Mechanical Integrity of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover procedures for determining the ability of photovoltaic modules to withstand the mechanical loads, stresses and deflections used to simulate, on an accelerated basis, high wind conditions, heavy snow and ice accumulation, and non-planar installation effects. 1.1.1 A static load test to 2400 Pa is used to simulate wind loads on both module surfaces 1.1.2 A static load test to 5400 Pa is used to simulate heavy snow and ice accumulation on the module front surface. 1.1.3 A twist test is used to simulate the non-planar mounting of a photovoltaic module by subjecting it to a twist angle of 1.2°. 1.1.4 A cyclic load test of 10 000 cycles duration and peak loading to 1440 Pa is used to simulate dynamic wind or other flexural loading. Such loading might occur during shipment or after installation at a particular location. 1.2 These test methods define photovoltaic test specimens and mounting methods, and specify parameters that must be recorded and reported. 1.3 Any individual mech...

  19. Guidelines for Standardized Testing of Broadband Seismometers and Accelerometers

    Science.gov (United States)

    Hutt, Charles R.; Evans, John R.; Followill, Fred; Nigbor, Robert L.; Wielandt, Erhard

    2010-01-01

    Testing and specification of seismic and earthquake-engineering sensors and recorders has been marked by significant variations in procedures and selected parameters. These variations cause difficulty in comparing such specifications and test results. In July 1989, and again in May 2005, the U.S. Geological Survey hosted international pub-lic/private workshops with the goal of defining widely accepted guidelines for the testing of seismological inertial sensors, seismometers, and accelerometers. The Proceedings of the 2005 workshop have been published and include as appendix 6 the report of the 1989 workshop. This document represents a collation and rationalization of a single set of formal guidelines for testing and specifying broadband seismometers and accelerometers.

  20. Standard practice for strain controlled thermomechanical fatigue testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice covers the determination of thermomechanical fatigue (TMF) properties of materials under uniaxially loaded strain-controlled conditions. A “thermomechanical” fatigue cycle is here defined as a condition where uniform temperature and strain fields over the specimen gage section are simultaneously varied and independently controlled. This practice is intended to address TMF testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. While this practice is specific to strain-controlled testing, many sections will provide useful information for force-controlled or stress-controlled TMF testing. 1.2 This practice allows for any maximum and minimum values of temperature and mechanical strain, and temperature-mechanical strain phasing, with the restriction being that such parameters remain cyclically constant throughout the duration of the test. No restrictions are placed on en...

  1. Development and standardization of perafom integrated aptitude test

    African Journals Online (AJOL)

    / selection/ placement and the measurement of intelligence prompted the development of Perafom Integrated Aptitude Test (PIAT). Following the due psychometric process of item selection, PIAT comprises 40 items derived from several ...

  2. Existing and Past Methods of Test and Rating Standards Related to Integrated Heat Pump Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Reedy, Wayne R. [Sentech, Inc.

    2010-07-01

    This report evaluates existing and past US methods of test and rating standards related to electrically operated air, water, and ground source air conditioners and heat pumps, 65,000 Btu/hr and under in capacity, that potentiality incorporate a potable water heating function. Two AHRI (formerly ARI) standards and three DOE waivers were identified as directly related. Six other AHRI standards related to the test and rating of base units were identified as of interest, as they would form the basis of any new comprehensive test procedure. Numerous other AHRI and ASHRAE component test standards were also identified as perhaps being of help in developing a comprehensive test procedure.

  3. Similar tests and the standardized log likelihood ratio statistic

    DEFF Research Database (Denmark)

    Jensen, Jens Ledet

    1986-01-01

    When testing an affine hypothesis in an exponential family the 'ideal' procedure is to calculate the exact similar test, or an approximation to this, based on the conditional distribution given the minimal sufficient statistic under the null hypothesis. By contrast to this there is a 'primitive' ....../2). As an example we consider inference for the mean of a log normal distribution in detail. © 1986 Biometrika Trust....

  4. Predicting standard penetration test N-value from cone penetration test data using artificial neural networks

    Directory of Open Access Journals (Sweden)

    Bashar Tarawneh

    2017-01-01

    Full Text Available Standard Penetration Test (SPT and Cone Penetration Test (CPT are the most frequently used field tests to estimate soil parameters for geotechnical analysis and design. Numerous soil parameters are related to the SPT N-value. In contrast, CPT is becoming more popular for site investigation and geotechnical design. Correlation of CPT data with SPT N-value is very beneficial since most of the field parameters are related to SPT N-values. A back-propagation artificial neural network (ANN model was developed to predict the N60-value from CPT data. Data used in this study consisted of 109 CPT-SPT pairs for sand, sandy silt, and silty sand soils. The ANN model input variables are: CPT tip resistance (qc, effective vertical stress (σv′, and CPT sleeve friction (fs. A different set of SPT-CPT data was used to check the reliability of the developed ANN model. It was shown that ANN model either under-predicted the N60-value by 7–16% or over-predicted it by 7–20%. It is concluded that back-propagation neural networks is a good tool to predict N60-value from CPT data with acceptable accuracy.

  5. Standard practice for ultrasonic testing of wrought products

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2013-01-01

    1.1 Purpose—This practice establishes the minimum requirements for ultrasonic examination of wrought products. Note 1—This standard was adopted to replace MIL-STD-2154, 30 Sept. 1982. This standard is intended to be used for the same applications as the document which it replaced. Users should carefully review its requirements when considering its use for new, or different applications, or both. 1.2 Application—This practice is applicable for examination of materials such as, wrought metals and wrought metal products. 1.2.1 Wrought Aluminum Alloy Products—Examination shall be in accordance with Practice B 594. 1.3 Acceptance Class—When examination is performed in accordance with this practice, engineering drawings, specifications, or other applicable documents shall indicate the acceptance criteria. Five ultrasonic acceptance classes are defined in Table 1. One or more of these classes may be used to establish the acceptance criteria or additional or alternate criteria may be specified. 1.4 Ord...

  6. 9 CFR 147.1 - The standard tube agglutination test. 1

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false The standard tube agglutination test... Blood Testing Procedures § 147.1 The standard tube agglutination test. 1 1 The procedure described is a... alternate medium for the preparation of tube agglutination antigen. The TG medium, formerly used for the...

  7. 9 CFR 147.7 - Standard test procedures for mycoplasma. 5

    Science.gov (United States)

    2010-01-01

    ... Blood Testing Procedures § 147.7 Standard test procedures for mycoplasma. 5 5 For additional information... pipette or standardized loop (rinsed between samples) to 11/2 inch squares on a ruled glass plate. Limit... deposit resuspended to give a 25 percent suspension of packed RBC's in Alsever's solution. (In testing...

  8. A Case Study of Rural New Mexico K-12 Teachers' Perceptions of Standardized Testing

    Science.gov (United States)

    Hite-Pope, Kim

    2017-01-01

    The purpose of this paper was to examine K-12 teachers' classroom experiences with standardized testing in rural New Mexico schools. Standardized tests have significantly changed the landscape of education with the use of students' test scores as a determining factor for advancement or failure for teachers (Simpson, Lacava, & Graner, 2013).…

  9. A Standard Platform for Testing and Comparison of MDAO Architectures

    Science.gov (United States)

    Gray, Justin S.; Moore, Kenneth T.; Hearn, Tristan A.; Naylor, Bret A.

    2012-01-01

    The Multidisciplinary Design Analysis and Optimization (MDAO) community has developed a multitude of algorithms and techniques, called architectures, for performing optimizations on complex engineering systems which involve coupling between multiple discipline analyses. These architectures seek to efficiently handle optimizations with computationally expensive analyses including multiple disciplines. We propose a new testing procedure that can provide a quantitative and qualitative means of comparison among architectures. The proposed test procedure is implemented within the open source framework, OpenMDAO, and comparative results are presented for five well-known architectures: MDF, IDF, CO, BLISS, and BLISS-2000. We also demonstrate how using open source soft- ware development methods can allow the MDAO community to submit new problems and architectures to keep the test suite relevant.

  10. Evaluation of Desensol As a Standard Patch Test Kit

    Directory of Open Access Journals (Sweden)

    K C Shah

    1987-01-01

    Full Text Available In a study undertaken to find out the usefulness of ′Desensol′ patch test kit to detect contact allergens, in 200 cases revealed 24 cases with negative patch test with all the antigens and 55 cases reacted to even the Vaseline control. -Excluding these 79 cases, the common contact allergens were potassium bichr6ma,te, (40.49%, TMTD(28.92%, PPD(24.79%, epoxy resin (23.14%, colophony (19.0%, nickel sulfate (19.0%, Framycetin (19.0% and nitrofurazone (19.0%. Desensol patch test kit is lacking in certain antigens while in our country due to varied environmental factors and social customs, a person is exposed to a large number of natural and man-made contact allergens. So usefulness of such a kit like. Desensol is limited.

  11. [Reference Intervals of Standard Test Items in Ningen Dock Examination].

    Science.gov (United States)

    Yamakado, Minoru

    2016-03-01

    Reference intervals (RIs) were derived from records of 1,499,288 individuals who underwent ningen dock examination in 188 institutes which belong to Japan Society of Ningen Dock in 2012. Targets were 27 basic laboratory tests, including the body mass index (BMI) and systolic and diastolic blood pressures (SBP, DBP). Individuals fulfilling strict criteria were chosen: SBP dock results will enable the appropriate interpretation of test results in health screening, and promote the effective application of CDLs for therapeutic intervention, taking into account the sex, age, and other health attributes.

  12. Factors influencing the selection of standardized tests for the diagnosis of specific language impairment.

    Science.gov (United States)

    Betz, Stacy K; Eickhoff, Jessica R; Sullivan, Shanleigh F

    2013-04-01

    Standardized tests are one of the primary assessment tools used by speech-language pathologists (SLPs) to diagnose child language impairment. Numerous child language tests are commercially available; however, it is unknown what factors lead clinicians to select particular tests to use in clinical practice. This study investigated whether the quality of standardized tests, as measured by the test's psychometric properties, is related to how frequently the tests are used in clinical practice. A total of 364 SLPs completed a survey regarding how frequently they used specific standardized tests when diagnosing suspected specific language impairment (SLI). The test manuals for 55 tests were reviewed to determine whether test characteristics, such as test reliability, validity, and accuracy, correlated with the frequency of test use. The most frequently used standardized tests were omnibus measures (e.g., Clinical Evaluation of Language Fundamentals-Fourth Edition [Semel, Wiig, & Secord, 2003], Preschool Language Scale, Fourth Edition [Zimmerman, Steiner, & Pond, 2002]) and single-word vocabulary measures (e.g., Peabody Picture Vocabulary Test, Fourth Edition [Dunn & Dunn, 2007]). Publication year was the only test characteristic that correlated significantly with the frequency of test use. The quality of a standardized test, as measured by the test's psychometric properties, does not appear to influence how frequently a test is used. These results highlight the need for increased evidence-based practice when diagnosing children with language impairment.

  13. Minimum Library Use Skills: Standards, Test, and Bibliography.

    Science.gov (United States)

    Carr, Jo Ann, Ed.

    Compiled by the Wisconsin Association of Academic Librarians' (WAAL) Education and Library Use Committee, the Test of Minimum Library Use Skills provides examples of questions which may be used to assess students' knowledge of the 13 minimum library use skills adapted by the WAAL membership in 1983. The 59 multiple choice questions that make up…

  14. Standard Test Methods for Constituent Content of Composite Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods determine the constituent content of composite materials by one of two approaches. Method I physically removes the matrix by digestion or ignition by one of seven procedures, leaving the reinforcement essentially unaffected and thus allowing calculation of reinforcement or matrix content (by weight or volume) as well as percent void volume. Method II, applicable only to laminate materials of known fiber areal weight, calculates reinforcement or matrix content (by weight or volume), and the cured ply thickness, based on the measured thickness of the laminate. Method II is not applicable to the measurement of void volume. 1.1.1 These test methods are primarily intended for two-part composite material systems. However, special provisions can be made to extend these test methods to filled material systems with more than two constituents, though not all test results can be determined in every case. 1.1.2 The procedures contained within have been designed to be particularly effective for ce...

  15. Testing the minimal supersymmetric standard model with the mass ...

    Indian Academy of Sciences (India)

    S Heinemeyer et al particles (see e.g. refs [5,6]). Consequently, a precise theoretical prediction for. MW in terms of the model parameters is of utmost importance for present and future electroweak precision tests. A precise prediction for MW in the MSSM is also needed as a part of the 'SPA Convention and Project' (see ref.

  16. Analysis of Individual "Test Of Astronomy STandards" (TOAST) Item Responses

    Science.gov (United States)

    Slater, Stephanie J.; Schleigh, Sharon Price; Stork, Debra J.

    2015-01-01

    The development of valid and reliable strategies to efficiently determine the knowledge landscape of introductory astronomy college students is an effort of great interest to the astronomy education community. This study examines individual item response rates from a widely used conceptual understanding survey, the Test Of Astronomy Standards…

  17. Testing the Standard Model with the Primordial Inflation Explorer

    Science.gov (United States)

    Kogut, Alan J.

    2011-01-01

    The Primordial Inflation Explorer is an Explorer-class mission to measure the gravity-wave signature of primordial inflation through its distinctive imprint on the linear polarization of the cosmic microwave background. PIXIE uses an innovative optical design to achieve background-limited sensitivity in 400 spectral channels spanning 2.5 decades in frequency from 30 GHz to 6 THz (1 cm to 50 micron wavelength). The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r < 10A{-3) at 5 standard deviations. The rich PIXIE data set will also constrain physical processes ranging from Big Bang cosmology to the nature of the first stars to physical conditions within the interstellar medium of the Galaxy. I describe the PIXIE instrument and mission architecture needed to detect the inflationary signature using only 4 semiconductor bolometers.

  18. Standard-C hydrogen monitoring system acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, T.C.

    1994-09-02

    The primary function of the standard-C hydrogen monitoring system (SHMS) is to monitor specifically for hydrogen in the waste tank atmosphere which may also contain (but not be limited to) unknown quantities of air, nitrous oxide, ammonia, water vapor, carbon dioxide, carbon monoxide, and other gaseous constituents. The SHMS will consist of hydrogen specific monitors, a grab sampler to collect samples for laboratory analysis, a gas chromatograph, and the gas sample collection system necessary to support the operation of the instrumentation. This system will be located in a cabinet placed at the tank of interest. The purpose of this document is to demonstrate that the SHMS is constructed as intended by design.

  19. Handover checklist: testing a standardization process in an Italian hospital

    Directory of Open Access Journals (Sweden)

    Ferorelli D

    2017-05-01

    Full Text Available Davide Ferorelli,1 Teresa Giandola,2 Mariangela Laterza,2 Biagio Solarino,2 Angela Pezzolla,3 Fiorenza Zotti,2 Alessandro Dell’Erba1 1Interdisciplinary Department of Medicine, 2Section of Legal Medicine, 3Department of Emergency and Organ Transplantation, University of Bari, Bari, Italy Objectives: This study aimed to standardize and rationalize the handover, a critical and essential moment in common health care practices, through the realization of an efficient and standardized checklist, which could be used daily to ensure complete, thorough and effective handover. The principal purpose of the implementation of the handover is to reduce errors due to superficial and insufficient communication.Methods: The “operative group” defined the phases to the realization of the delineated aims: at first, the direct observation and the consequent realization of a handover checklist model and then, the experimental phases (trials. The handover checklist model was used for a month and it was daily and duly completed by the doctors who took part in the trial. To prove the success of the study, three questionnaires were distributed on different occasions.Results: Analyzing the answers to the questionnaires, the importance of the handover has come to light and that for the most part, the doctors consider it an essential and irreplaceable moment in daily health care work. Moreover, it became obvious that the use of the handover checklist guaranteed a considerable improvement in the traditional handover in terms of security, completeness, care continuity and clarity. The handover checklist was completely appreciated by the majority of the participant doctors who agree with the definitive introduction of it in their unit.Conclusions: Our study indicated the consistency of the handover checklist as an instrument to implement the handover and, indirectly, to improve the quality of the care. Keywords: clinical risk management, handover checklist, health care

  20. Twenty Years On!: Updating the IEA BESTEST Building Thermal Fabric Test Cases for ASHRAE Standard 140

    Energy Technology Data Exchange (ETDEWEB)

    Judkoff, R. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Neymark, J. [J. Neymark & Associates, Golden, CO (United States)

    2013-07-01

    ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs applies the IEA BESTEST building thermal fabric test cases and example simulation results originally published in 1995. These software accuracy test cases and their example simulation results, which comprise the first test suite adapted for the initial 2001 version of Standard 140, are approaching their 20th anniversary. In response to the evolution of the state of the art in building thermal fabric modeling since the test cases and example simulation results were developed, work is commencing to update the normative test specification and the informative example results.

  1. 16 CFR 1616.35 - Use of alternate apparatus, procedures, or criteria for testing under the standard.

    Science.gov (United States)

    2010-01-01

    ... SAFETY COMMISSION FLAMMABLE FABRICS ACT REGULATIONS STANDARD FOR THE FLAMMABILITY OF CHILDREN'S SLEEPWEAR... criteria for testing under the standard. (a) The Standard for the Flammability of Children's Sleepwear...

  2. 16 CFR 1615.35 - Use of alternate apparatus, procedures, or criteria for testing under the standard.

    Science.gov (United States)

    2010-01-01

    ... SAFETY COMMISSION FLAMMABLE FABRICS ACT REGULATIONS STANDARD FOR THE FLAMMABILITY OF CHILDREN'S SLEEPWEAR... criteria for testing under the standard. (a) The Standard for the Flammability of Children's Sleepwear...

  3. The National Shipbuilding Research Program. Acceptance Standards for Nondestructive Test Not Required by Classification (Phase 2)

    National Research Council Canada - National Science Library

    Stern, I. L; Wheatcroft, M; Ku, D. Y; Cantore, D

    1985-01-01

    Current ABS requirements relative to nondestructive test and acceptance standards for radiographic and ultrasonic inspection are mainly intended for intersecting full penetration welds within the midship...

  4. Test Standards for Contingency Base Waste-to-Energy Technologies

    Science.gov (United States)

    2015-08-01

    followed by gas evolution from the combustion/ pyrolysis reactions which will vary over time. A very different sampling approach may be needed for batch... pyrolysis /combustion begins). 3) Potential Additional Sampling and Analysis a) Review local regulatory requirements for the test program and/or...Electric, and Alternate Fuels, Washington DC, May 2007; http://www.eia.gov/totalenergy/data/monthly/ pdf /historical/msw.pdf. 18. Xerox®, Sept 2004

  5. Generation and implementation of IRNSS Standard Positioning Signal

    Directory of Open Access Journals (Sweden)

    A.R. Yashaswini

    2016-09-01

    Full Text Available The two sorts of services given by the Indian Regional Navigational Satellite System (IRNSS satellites are Standard Positioning Service (SPS and Restricted Service (RS. Both services will be given at two frequencies of L5 (1164.5 MHz and S (2472.5 MHz band. The code sequences utilized as a part of SPS are Pseudo Ranging Noise (PRN codes. They utilize gold codes for navigational data transmission in SPS downlink. PRN sequence code is the secondary code and the gold code is the primary code. The greater part of the global positioning system works on Code Division Multiple Access (CDMA, in which Pseudo Random Code (PRN sequences are required for the systems. In this paper a study is made on the generation and properties of the PRN codes from the navigational system viewpoint. This paper additionally shows the design and implementation of PRN code on Spartan-II FPGA hardware. The generated SPS PRN code results are approved from hardware with the simulation results and examination of the properties of the PRN codes positively acquired. This paper likewise exhibits the execution analysis and simulation of Auto-Correlation Function (ACF and Cross-Correlation Function (CCF properties for PRN sequence. The simulations of SPS PRN codes were completed utilizing the Xilinx ISE test system and MATLAB apparatus. The simulated test outcomes are within the theoretical limits.

  6. Impact of looping on middle school science standardized achievement tests

    Science.gov (United States)

    Barger, Tammy M.

    Looping may be defined as a teacher remaining with a group of students for multiple academic years. In this quantitative study, looping was examined as a factor on science achievement. State-wide eighth grade school level 2010 Pennsylvania System of School Assessment (PSSA) data were used. By responding to a mailing, school administrators indicated if 2010 eighth grade students had or had not been looped. The schools' percentage of advanced and proficient Science PSSA data were used to determine if the independent variable had a significant impact on science achievement. The results of the independent t-test analysis suggest that looping does not contribute to science achievement for this study sample.

  7. Chickadees fail standardized operant tests for octave equivalence.

    Science.gov (United States)

    Hoeschele, Marisa; Weisman, Ronald G; Guillette, Lauren M; Hahn, Allison H; Sturdy, Christopher B

    2013-07-01

    Octave equivalence occurs when an observer judges notes separated by a doubling in frequency perceptually similar. The octave appears to form the basis of pitch change in all human cultures and thus may be of biological origin. Previously, we developed a nonverbal operant conditioning test of octave generalization and transfer in humans. The results of this testing showed that humans with and without musical training perceive the octave relationship between pitches. Our goal in the current study was to determine whether black-capped chickadees, a North American songbird, perceive octave equivalence. We chose these chickadees because of their reliance on pitch in assessing conspecific vocalizations, our strong background knowledge on their pitch height perception (log-linear perception of frequency), and the phylogenetic disparity between them and humans. Compared to humans, songbirds are highly skilled at using pitch height perception to classify pitches into ranges, independent of the octave. Our results suggest that chickadees used that skill, rather than octave equivalence, to transfer the note-range discrimination from one octave to the next. In contrast, there is evidence that at least some mammals, including humans, do perceive octave equivalence.

  8. LHC BLM Single Channel Connectivity Test using the Standard Installation

    CERN Document Server

    Emery, J; Effinger, E; Ferioli, G; Zamantzas, C; Ikeda, H; Verhagen, E

    2009-01-01

    For the LHC Beam Loss Measurement system (BLM), the high voltage supply of the ionisation chambers and the secondary emission detectors is used to test their connectivity. A harmonic modulation of 0.03 Hz results in a current signal of about 100pA measured by the beam loss acquisition electronics. The signal is analyzed and the measured amplitude and phase are compared with individual channel limits for the 4000 channels. It is foreseen to execute an automatic procedure for all channels every 12 hours which takes about 20 minutes. The paper will present the design of the system, the circuit simulations, measurements of systematic dependencies of different channels and the reproducibility of the amplitude and phase measurements.

  9. Standards for measurements and testing of wind turbine power quality

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, P. [Risoe National Lab., Roskilde (Denmark); Gerdes, G.; Klosse, R.; Santjer, F. [DEWI, Wilhelmshaven (Germany); Robertson, N.; Davy, W. [NEL, Glasgow (United Kingdom); Koulouvari, M.; Morfiadakis, E. [CRES, Pikermi (Greece); Larsson, Aa. [Chalmers Univ. of Technology, Goeteborg (Sweden)

    1999-03-01

    The present paper describes the work done in power quality sub-task of the project `European Wind Turbine Testing Procedure Developments` funded by the EU SMT program. The objective of the power quality sub-task has been to make analyses and new recommendation(s) for the standardisation of measurement and verification of wind turbine power quality. The work has been organised in three major activities. The first activity has been to propose measurement procedures and to verify existing and new measurement procedures. This activity has also involved a comparison of the measurements and data processing of the participating partners. The second activity has been to investigate the influence of terrain, grid properties and wind farm summation on the power quality of wind turbines with constant rotor speed. The third activity has been to investigate the influence of terrain, grid properties and wind farm summation on the power quality of wind turbines with variable rotor speed. (au)

  10. Standard Guide for Benchmark Testing of Light Water Reactor Calculations

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide covers general approaches for benchmarking neutron transport calculations in light water reactor systems. A companion guide (Guide E2005) covers use of benchmark fields for testing neutron transport calculations and cross sections in well controlled environments. This guide covers experimental benchmarking of neutron fluence calculations (or calculations of other exposure parameters such as dpa) in more complex geometries relevant to reactor surveillance. Particular sections of the guide discuss: the use of well-characterized benchmark neutron fields to provide an indication of the accuracy of the calculational methods and nuclear data when applied to typical cases; and the use of plant specific measurements to indicate bias in individual plant calculations. Use of these two benchmark techniques will serve to limit plant-specific calculational uncertainty, and, when combined with analytical uncertainty estimates for the calculations, will provide uncertainty estimates for reactor fluences with ...

  11. 75 FR 48728 - The Hydrostatic Testing Provision of the Portable Fire Extinguishers Standard; Extension of the...

    Science.gov (United States)

    2010-08-11

    ... Extinguishers Standard; Extension of the Office of Management and Budget's (OMB) Approval of the Information... the Hydrostatic Testing provision of the Portable Fire Extinguishers Standard for General Industry (29... the Portable Fire Extinguishers Standard are necessary to reduce workers' risk of death or serious...

  12. 78 FR 70324 - Thy Hydrostatic Testing Provision of the Portable Fire Extinguishers Standard; Extension of the...

    Science.gov (United States)

    2013-11-25

    ... Extinguishers Standard; Extension of the Office of Management and Budget's (OMB) Approval of the Information... contained in the Hydrostatic Testing provision of the Portable Fire Extinguishers Standard for General... Extinguishers Standard are necessary to reduce workers' risk of death or serious injury by ensuring that...

  13. 16 CFR 1610.35 - Procedures for testing special types of textile fabrics under the standard.

    Science.gov (United States)

    2010-01-01

    ... textile fabrics under the standard. 1610.35 Section 1610.35 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT REGULATIONS STANDARD FOR THE FLAMMABILITY OF CLOTHING TEXTILES Rules and Regulations § 1610.35 Procedures for testing special types of textile fabrics under the standard. (a) Fabric...

  14. Development of a standardized testing system for orthodontic sliding mechanics.

    Science.gov (United States)

    Fathimani, Maryam; Melenka, Garrett W; Romanyk, Dan L; Toogood, Roger W; Heo, Giseon; Carey, Jason P; Major, Paul W

    2015-01-01

    The primary objective of this study was to develop a computer-controlled three-dimensional friction measuring system, the orthodontic friction simulator (OFS). A clinically-based in vitro experiment considering wet and dry friction for conventionally and self-ligated brackets is presented to elucidate debate surrounding sliding mechanics and illustrate capabilities of the OFS. The OFS was designed and manufactured using sound engineering principles and with the primary concern of being able to measure all forces and moments generated during sliding mechanics. This required the implementation of a six-axis load cell. A variety of translation and rotation stages were also incorporated to allow for precise positioning of the bracket relative to the archwire. Once designed and built, the OFS was then used to compare conventional and self-ligation methods in both the wet and dry state. Damon Q brackets and 0.018″ × 0.025″ stainless steel wires were used for all tests with a sample size of n = 65 for each ligation method. Archwires were pulled at a speed of 0.1 mm/s in 11 increments of 0.1 mm. At each increment, the bracket would be rotated 0.5° resulting in a total archwire travel of 1.1 mm and a second-order bracket angle range of 0°-5°. A repeated measures ANOVA was conducted to determine if ligation method and/or addition of moisture effected resulting orthodontic loads. The developed equipment for studying orthodontic sliding mechanics was able to measure forces and moments in all three directions; a capability not previously realized in the literature. Additionally, it was found that passive ligation significantly reduced resistance to sliding, P ≤ 0.05, while the dry/wet state did not. The OFS certainly proved to be an adequate instrument for the scientific evaluation of orthodontic sliding mechanics. It is capable of measuring loads generated in all directions and is a fully automated apparatus allowing for simple and repeatable friction

  15. Diagnostic tests for Helicobacter pylori : A prospective evaluation of their accuracy, without selecting a single test as the gold standard

    NARCIS (Netherlands)

    Thijs, J C; van Zwet, A A; Thijs, W J; Oey, H B; Karrenbeld, A; Stellaard, F; Luijt, D S; Meyer, B C; Kleibeuker, J H

    1996-01-01

    OBJECTIVE: To assess the accuracy of six commonly used diagnostic tests for Helicobacter pylori in a prospective study without using any specific test as the gold standard (the patient was regarded as H. pylori-infected if two or more tests, whatever their nature, were positive). METHODS: In 105

  16. Standard tests for the characterization of roofing slate pathologies

    Directory of Open Access Journals (Sweden)

    Cárdenes, V.

    2012-06-01

    Full Text Available The pathologies formed in slate roofs are mainly due to the presence of potentially unstable minerals (iron sulfides, carbonates and organic matter. These minerals may become altered by the effect of environmental agents, once the slate roof is finished. The pathologies are mainly associated with oxidation and gypsification processes of the cited mineral phases. In this work, the potential pathologies of several Spanish roofing slates are identified, using the tests defined in the European Norms EN 12326:2005, 14147:2004 and 11597:2007.

    Las patologías que se originan en pizarra para cubiertas son debidas fundamentalmente a la presencia de materiales alterables (sulfuros de hierro, carbonatos y materia orgánica. Estos minerales pueden llegar a alterarse por efecto de los agentes medioambientales, una vez que la pizarra es puesta en obra. Las patologías están principalmente asociadas a procesos de oxidación y yesificación de las citadas fases minerales. En este trabajo se determinan las patologías potenciales de varias pizarras para cubiertas españolas, utilizando los ensayos definidos en las normas UNE-EN 12326:2005, 14147:2004 y 11597:2007.

  17. Standard practice for conducting and evaluating laboratory corrosions tests in soils

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This practice covers procedures for conducting laboratory corrosion tests in soils to evaluate the corrosive attack on engineering materials. 1.2 This practice covers specimen selection and preparation, test environments, and evaluation of test results. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  18. Political Judgement, Freedom of Thought, and Standardized Testing: A Critical Enquiry

    Science.gov (United States)

    Schuler, Matthew Edward

    2012-01-01

    The practice of "standardized" testing has been embedded in United States federal education policy since at least the passage of the Elementary and Secondary Education Act of 1965. The roots of standardized testing in American education, grounded in Kantian "Modern Thought," can be traced to the U.S. Military Academy at…

  19. Recent progress on test evidence, standardization and design of protection for exterior openings

    Directory of Open Access Journals (Sweden)

    Strøm Ruth Astrid

    2016-01-01

    A number of different fire scenarios that elements in vented facades/constructions can be exposed to have been studied. New test standards have been developed for the last few years and are explained. Finally, this paper evaluate how different fire stop products perform in different fire scenarios and which test standards are applicable.

  20. Standardized measures of critical thinking. Experience with the California Critical Thinking Tests.

    Science.gov (United States)

    Leppa, C J

    1997-01-01

    Standardized measures of student critical thinking are an attractive option for nursing educators under pressure to demonstrate student higher order thinking skills. One program's experience using the California Critical Thinking Skills Test and the California Critical Thinking Dispositions Inventory illustrates some of the problems of using standardized test and potential solutions.

  1. 75 FR 34064 - Manufactured Home Construction and Safety Standards, Test Procedures for Roof Trusses

    Science.gov (United States)

    2010-06-16

    ... reduce the overload test period from 12 hours to 6 hours, and allow the test specimens to be of average... URBAN DEVELOPMENT 24 CFR Part 3280 RIN 2502-A172 Manufactured Home Construction and Safety Standards... Construction and Safety Standards by adopting proposals made by the Manufactured Home Consensus Committee (MHCC...

  2. Increased sensitivity of patch testing by standardized tape stripping beforehand: a multicentre diagnostic accuracy study.

    Science.gov (United States)

    Dickel, Heinrich; Kreft, Burkhard; Kuss, Oliver; Worm, Margitta; Soost, Stephanie; Brasch, Jochen; Pfützner, Wolfgang; Grabbe, Jürgen; Angelova-Fischer, Irena; Elsner, Peter; Fluhr, Joachim; Altmeyer, Peter; Geier, Johannes

    2010-05-01

    As a modification of patch testing, the strip patch test was established to obtain more sensitive and reliable test results. Comparative data on diagnostic accuracy for both tests are missing. To compare the diagnostic accuracy of strip patch tests and patch tests in detecting sensitizations in patients with suspected allergic contact dermatitis by using patient history as the reference standard. In a multicentre, prospective, investigator-blinded study 790 patients were enrolled. The defined reference standard was established prior to patch testing. Patch tests were performed with nickel sulfate, potassium dichromate, and lanolin alcohol. Duplicate tests were simultaneously performed on both sides of the back, of which one randomly chosen side was tape stripped beforehand, according to a standardized procedure. Primary outcome was the difference in sensitivity between strip patch test and patch test. Seven hundred and eighty-seven patients were included in the analysis. Strip patch tests detected considerably more sensitization to nickel sulfate and potassium dichromate than patch tests: differences of sensitivities were 16.4% (95% CI, 8.7-24.1%) for nickel sulfate and 25.0% (95% CI, 8.9-41.0%) for potassium dichromate, both favouring the strip patch test. The standardized strip patch test proved to be accurate and clinically safe and is promising to improve diagnosis of allergic contact dermatitis beyond the patch test.

  3. 9 CFR 147.9 - Standard test procedures for avian influenza.

    Science.gov (United States)

    2010-01-01

    ... influenza. 147.9 Section 147.9 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Blood Testing Procedures § 147.9 Standard test procedures for avian influenza. (a) The agar gel immunodiffusion (AGID) test should be considered the basic screening test for antibodies to Type A influenza...

  4. Standard test method for ball punch deformation of metallic sheet material

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the procedure for conducting the ball punch deformation test for metallic sheet materials intended for forming applications. The test applies to specimens with thicknesses between 0.008 and 0.080 in. (0.20 and 2.00 mm). 1.2 The values stated in inch–pound units are to be regarded as the standard. Note 1—The ball punch deformation test is intended to replace the Olsen cup test by standardizing many of the test parameters that previously have been left to the discretion of the testing laboratory. Note 2—The modified Erichsen test has been standardized in Europe. The main differences between the ball punch deformation test and the Erichsen test are the diameters of the penetrator and the dies. Erichsen cup heights are given in SI units. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This standard does...

  5. Standard Test Method for Testing Polymeric Seal Materials for Geothermal and/or High Temperature Service Under Sealing Stress

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This test method covers the initial evaluation of (screening) polymeric materials for seals under static sealing stress and at elevated temperatures. 1.2 This test method applies to geothermal service only if used in conjunction with Test Method E 1068. 1.3 The test fluid is distilled water. 1.4 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. High-Stakes Standardized Testing & Marginalized Youth: An Examination of the Impact on Those Who Fail

    Science.gov (United States)

    Kearns, Laura-Lee

    2011-01-01

    This study examines the impact of high-stakes, large-scale, standardized literacy testing on youth who have failed the Ontario Secondary School Literacy Test. Interviews with youth indicate that the unintended impact of high-stakes testing is more problematic than policy makers and educators may realize. In contrast to literacy policy's aims to…

  7. Criterion-Referenced Tests in Science: An Investigation of Reliability, Validity, and Standards-Setting.

    Science.gov (United States)

    Lang, Harry G.

    1982-01-01

    Reliability, validity, and standards-setting procedure for a criterion-referenced test (Test of Metric Skills) were examined for use in science curricula. Results indicate a number of factors influencing test reliability/validity and that science teachers need to be aware of these factors to enhance accuracy of their judgments. (Author/JN)

  8. Non-invasive measurement of adrenal response after standardized exercise tests in prepubertal children

    NARCIS (Netherlands)

    Heijsman, Sigrid M.; Koers, Nicoline F.; Bocca, Gianni; van der Veen, Betty S.; Appelhof, Maaike; Kamps, Arvid W. A.

    Objective: To determine the feasibility of non-invasive evaluation of adrenal response in healthy prepubertal children by standardized exercise tests. Methods: On separate occasions, healthy prepubertal children performed a submaximal cycling test, a maximal cycling test, and a 20-m shuttle-run

  9. Standardized tests of handwriting readiness: a systematic review of the literature

    NARCIS (Netherlands)

    Hartingsveldt, M.J. van; Groot, I.J.M. de; Aarts, P.B.M.; Nijhuis-Van der Sanden, M.W.G.

    2011-01-01

    AIM: To establish if there are psychometrically sound standardized tests or test items to assess handwriting readiness in 5- and 6-year-old children on the levels of occupations activities/tasks and performance. METHOD: Electronic databases were searched to identify measurement instruments. Tests

  10. Factors Influencing the Selection of Standardized Tests for the Diagnosis of Specific Language Impairment

    Science.gov (United States)

    Betz, Stacy K.; Eickhoff, Jessica R.; Sullivan, Shanleigh F.

    2013-01-01

    Purpose: Standardized tests are one of the primary assessment tools used by speech-language pathologists (SLPs) to diagnose child language impairment. Numerous child language tests are commercially available; however, it is unknown what factors lead clinicians to select particular tests to use in clinical practice. This study investigated whether…

  11. Synthesizing Information from Language Samples and Standardized Tests in School-Age Bilingual Assessment

    Science.gov (United States)

    Ebert, Kerry Danahy; Pham, Giang

    2017-01-01

    Purpose: Although language samples and standardized tests are regularly used in assessment, few studies provide clinical guidance on how to synthesize information from these testing tools. This study extends previous work on the relations between tests and language samples to a new population--school-age bilingual speakers with primary language…

  12. Development of Proposed Standards for Testing Solar Collectors and Thermal Storage Devices. NBS Technical Note 899.

    Science.gov (United States)

    Hill, James E.; And Others

    A study has been made at the National Bureau of Standards of the different techniques that are or could be used for testing solar collectors and thermal storage devices that are used in solar heating and cooling systems. This report reviews the various testing methods and outlines a recommended test procedure, including apparatus and…

  13. Standard test method for exfoliation corrosion susceptibility in 2XXX and 7XXX Series Aluminum Alloys (EXCO Test)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method covers a procedure for constant immersion exfoliation corrosion (EXCO) testing of high-strength 2XXX and 7XXX series aluminum alloys. Note 1—This test method was originally developed for research and development purposes; however, it is referenced, in specific material specifications, as applicable for evaluating production material (refer to Section 14 on Precision and Bias). 1.2 This test method applies to all wrought products such as sheet, plate, extrusions, and forgings produced from conventional ingot metallurgy process. 1.3 This test method can be used with any form of specimen or part that can be immersed in the test solution. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. Standard Errors and Confidence Intervals of Norm Statistics for Educational and Psychological Tests.

    Science.gov (United States)

    Oosterhuis, Hannah E M; van der Ark, L Andries; Sijtsma, Klaas

    2016-11-14

    Norm statistics allow for the interpretation of scores on psychological and educational tests, by relating the test score of an individual test taker to the test scores of individuals belonging to the same gender, age, or education groups, et cetera. Given the uncertainty due to sampling error, one would expect researchers to report standard errors for norm statistics. In practice, standard errors are seldom reported; they are either unavailable or derived under strong distributional assumptions that may not be realistic for test scores. We derived standard errors for four norm statistics (standard deviation, percentile ranks, stanine boundaries and Z-scores) under the mild assumption that the test scores are multinomially distributed. A simulation study showed that the standard errors were unbiased and that corresponding Wald-based confidence intervals had good coverage. Finally, we discuss the possibilities for applying the standard errors in practical test use in education and psychology. The procedure is provided via the R function check.norms, which is available in the mokken package.

  15. Does Test Item Performance Increase with Test-to-Standards Alignment?

    Science.gov (United States)

    Traynor, Anne

    2017-01-01

    Variation in test performance among examinees from different regions or national jurisdictions is often partially attributed to differences in the degree of content correspondence between local school or training program curricula, and the test of interest. This posited relationship between test-curriculum correspondence, or "alignment,"…

  16. Test Anxiety and a High-Stakes Standardized Reading Comprehension Test: A Behavioral Genetics Perspective

    Science.gov (United States)

    Wood, Sarah G.; Hart, Sara A.; Little, Callie W.; Phillips, Beth M.

    2016-01-01

    Past research suggests that reading comprehension test performance does not rely solely on targeted cognitive processes such as word reading, but also on other nontarget aspects such as test anxiety. Using a genetically sensitive design, we sought to understand the genetic and environmental etiology of the association between test anxiety and…

  17. Evaluation of standardized test methods to characterize fiber reinforced cement composites

    DEFF Research Database (Denmark)

    Paegle, Ieva; Fischer, Gregor

    2011-01-01

    This paper describes an investigation of standardized test methods to characterize fiber reinforced cementitious composites in terms of their behavior under flexural loading and its relation to their tensile stress-deformation response. Flexural testing and derivation of the tensile stress......-deformation response are preferred in standardized testing of Fiber Reinforced Cement Composites (FRCC) over the direct assessment of the tensile behavior because of the more convenient test setup and ease of specimen preparation. Four-point bending tests were carried out to evaluate the flexural response of FRCC...... and their results are compared to data obtained from direct tensile testing. The details of the formation of cracking are an important underlying assumption in the standardized evaluation procedures as well as in the established correlation models between flexural and tensile behavior. This detail has been...

  18. Student science achievement and the integration of Indigenous knowledge on standardized tests

    Science.gov (United States)

    Dupuis, Juliann; Abrams, Eleanor

    2017-09-01

    In this article, we examine how American Indian students in Montana performed on standardized state science assessments when a small number of test items based upon traditional science knowledge from a cultural curriculum, "Indian Education for All", were included. Montana is the first state in the US to mandate the use of a culturally relevant curriculum in all schools and to incorporate this curriculum into a portion of the standardized assessment items. This study compares White and American Indian student test scores on these particular test items to determine how White and American Indian students perform on culturally relevant test items compared to traditional standard science test items. The connections between student achievement on adapted culturally relevant science test items versus traditional items brings valuable insights to the fields of science education, research on student assessments, and Indigenous studies.

  19. Testing the Ratcheting Labor Standards proposal : Indonesia and the Shangri-La workers

    National Research Council Canada - National Science Library

    OWENS, Alexandra

    2004-01-01

    Using the recent labour dispute at the Shangri-La Hotel in Jakarta, Indonesia, to test some of the key elements and assumptions of the theory of international labour regulation, Ratcheting Labor Standards (RLS...

  20. Epidemiological cut-off values for Flavobacterium psychrophilum MIC data generated by a standard test protocol

    DEFF Research Database (Denmark)

    Smith, P.; Endris, R.; Kronvall, G.

    2016-01-01

    Epidemiological cut-off values were developed for application to antibiotic susceptibility data for Flavobacterium psychrophilum generated by standard CLSI test protocols. The MIC values for ten antibiotic agents against Flavobacterium psychrophilum were determined in two laboratories. For five...

  1. Review of application code and standards for mechanical and piping design of HANARO fuel test loop

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. Y.

    1998-02-01

    The design and installation of the irradiation test facility for verification test of the fuel performance are very important in connection with maximization of the utilization of HANARO. HANARO fuel test loop was designed in accordance with the same code and standards of nuclear power plant because HANARO FTL will be operated the high pressure and temperature same as nuclear power plant operation conditions. The objective of this study is to confirm the propriety of application code and standards for mechanical and piping of HANARO fuel test loop and to decide the technical specification of FTL systems. (author). 18 refs., 8 tabs., 6 figs.

  2. Standard test method for conducting drop-weight test to determine nil-ductility transition temperature of ferritic steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers the determination of the nil-ductility transition (NDT) temperature of ferritic steels, 5/8 in. (15.9 mm) and thicker. 1.2 This test method may be used whenever the inquiry, contract, order, or specification states that the steels are subject to fracture toughness requirements as determined by the drop-weight test. 1.3 The values stated in inch-pound units are to be regarded as the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Standard Test Method for Saltwater Pressure Immersion and Temperature Testing of Photovoltaic Modules for Marine Environments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method provides a procedure for determining the ability of photovoltaic modules to withstand repeated immersion or splash exposure by seawater as might be encountered when installed in a marine environment, such as a floating aid-to-navigation. A combined environmental cycling exposure with modules repeatedly submerged in simulated saltwater at varying temperatures and under repetitive pressurization provides an accelerated basis for evaluation of aging effects of a marine environment on module materials and construction. 1.2 This test method defines photovoltaic module test specimens and requirements for positioning modules for test, references suitable methods for determining changes in electrical performance and characteristics, and specifies parameters which must be recorded and reported. 1.3 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method. 1.4 The values stated in SI units are to be ...

  4. A standardized framework for the validation and verification of clinical molecular genetic tests.

    Science.gov (United States)

    Mattocks, Christopher J; Morris, Michael A; Matthijs, Gert; Swinnen, Elfriede; Corveleyn, Anniek; Dequeker, Els; Müller, Clemens R; Pratt, Victoria; Wallace, Andrew

    2010-12-01

    The validation and verification of laboratory methods and procedures before their use in clinical testing is essential for providing a safe and useful service to clinicians and patients. This paper outlines the principles of validation and verification in the context of clinical human molecular genetic testing. We describe implementation processes, types of tests and their key validation components, and suggest some relevant statistical approaches that can be used by individual laboratories to ensure that tests are conducted to defined standards.

  5. Comparison of Size Modulation Standard Automated Perimetry and Conventional Standard Automated Perimetry with a 10-2 Test Program in Glaucoma Patients.

    Science.gov (United States)

    Hirasawa, Kazunori; Takahashi, Natsumi; Satou, Tsukasa; Kasahara, Masayuki; Matsumura, Kazuhiro; Shoji, Nobuyuki

    2017-08-01

    This prospective observational study compared the performance of size modulation standard automated perimetry with the Octopus 600 10-2 test program, with stimulus size modulation during testing, based on stimulus intensity and conventional standard automated perimetry, with that of the Humphrey 10-2 test program in glaucoma patients. Eighty-seven eyes of 87 glaucoma patients underwent size modulation standard automated perimetry with Dynamic strategy and conventional standard automated perimetry using the SITA standard strategy. The main outcome measures were global indices, point-wise threshold, visual defect size and depth, reliability indices, and test duration; these were compared between size modulation standard automated perimetry and conventional standard automated perimetry. Global indices and point-wise threshold values between size modulation standard automated perimetry and conventional standard automated perimetry were moderately to strongly correlated (p 33.40, p modulation standard automated perimetry than with conventional standard automated perimetry, but the visual-field defect size was smaller (p modulation-standard automated perimetry than on conventional standard automated perimetry. The reliability indices, particularly the false-negative response, of size modulation standard automated perimetry were worse than those of conventional standard automated perimetry (p modulation standard automated perimetry than with conventional standard automated perimetry (p = 0.02). Global indices and the point-wise threshold value of the two testing modalities correlated well. However, the potential of a large stimulus presented at an area with a decreased sensitivity with size modulation standard automated perimetry could underestimate the actual threshold in the 10-2 test protocol, as compared with conventional standard automated perimetry.

  6. Standard Test Method for Measuring Heat Flux Using a Water-Cooled Calorimeter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the measurement of a steady heat flux to a given water-cooled surface by means of a system energy balance. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. Standard test method for uranium analysis in natural and waste water by X-ray fluorescence

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method applies for the determination of trace uranium content in waste water. It covers concentrations of U between 0.05 mg/L and 2 mg/L. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  8. Standard test method for determination of technetium-99 in uranium hexafluoride by liquid scintillation counting

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method is a quantitative method used to determine technetium-99 (99Tc) in uranium hexafluoride (UF6) by liquid scintillation counting. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. A Step Towards Electric Propulsion Testing Standards: Pressure Measurements and Effective Pumping Speeds

    Science.gov (United States)

    Dankanich, John W.; Swiatek, Michael W.; Yim, John T.

    2012-01-01

    The electric propulsion community has been implored to establish and implement a set of universally applicable test standards during the research, development, and qualification of electric propulsion systems. Existing practices are fallible and result in testing variations which leads to suspicious results, large margins in application, or aversion to mission infusion. Performance measurements and life testing under appropriate conditions can be costly and lengthy. Measurement practices must be consistent, accurate, and repeatable. Additionally, the measurements must be universally transportable across facilities throughout the development, qualification, spacecraft integration and on-orbit performance. A preliminary step to progress towards universally applicable testing standards is outlined for facility pressure measurements and effective pumping speed calculations. The standard has been applied to multiple facilities at the NASA Glenn Research Center. Test results and analyses of universality of measurements are presented herein.

  10. Standard Test Method for Gel Time of Carbon Fiber-Epoxy Prepreg

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers the determination of gel time of carbon fiber-epoxy tape and sheet. The test method is suitable for the measurement of gel time of resin systems having either high or low viscosity. 1.2 The values stated in SI units are to be regarded as standard. The values in parentheses are for reference only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. Bone plate-screw constructs for osteosynthesis - recommendations for standardized mechanical torsion and bending tests.

    Science.gov (United States)

    Schorler, Hendrik; Wendlandt, Robert; Jürgens, Christian; Schulz, Arndt-Peter; Kaddick, Christian; Capanni, Felix

    2017-12-18

    This paper follows up on a recent systematic review of test methods and parameters for biomechanical testing of bone plates and it is the first study that contains recommendations for standardized mechanical testing of bone plate-screw constructs for osteosynthesis. Following the testing philosophy of ASTM F382 and ISO 9585, we have developed standardized quasi-static and dynamic testing methods for straight linear and anatomically shaped plates, including locked type and conventional systems. The test specification comprises torsion and bending tests along the implant axis and therefore modifies and extends the methods proposed by ASTM F382. We present specific test setups in order to determine product-specific characteristics of the mechanical construct, consisting of the bone plate with corresponding screws (such as construct stiffness, yield strength, ultimate strength and fatigue properties) under the condition that it is rigidly fixed to "healthy bone". We also address specific testing requirements that are important for the purpose of standardization, such as the positioning of the construct for testing or the number of screws in the diaphysis and metaphysis. Finally, we define the outcome parameters and associated failure criteria related to quasi-static and dynamic testing for comparative purposes. This paper does not intend to replace biomechanical testing of those devices under physiological loading conditions.

  12. Linear shrinkage test: justification for its reintroduction as a standard South African test method

    CSIR Research Space (South Africa)

    Sampson, LR

    2009-06-04

    Full Text Available Several problems with the linear shrinkage test specified in Method A4 of the THM 1 1979 were addressed as part of this investigation in an effort to improve the alleged poor reproducibility of the test and justify its reintroduction into THM 1. A...

  13. Adults with poor reading skills: How lexical knowledge interacts with scores on standardized reading comprehension tests.

    Science.gov (United States)

    McKoon, Gail; Ratcliff, Roger

    2016-01-01

    Millions of adults in the United States lack the necessary literacy skills for most living wage jobs. For students from adult learning classes, we used a lexical decision task to measure their knowledge of words and we used a decision-making model (Ratcliff's, 1978, diffusion model) to abstract the mechanisms underlying their performance from their RTs and accuracy. We also collected scores for each participant on standardized IQ tests and standardized reading tests used commonly in the education literature. We found significant correlations between the model's estimates of the strengths with which words are represented in memory and scores for some of the standardized tests but not others. The findings point to the feasibility and utility of combining a test of word knowledge, lexical decision, that is well-established in psycholinguistic research, a decision-making model that supplies information about underlying mechanisms, and standardized tests. The goal for future research is to use this combination of approaches to understand better how basic processes relate to standardized tests with the eventual aim of understanding what these tests are measuring and what the specific difficulties are for individual, low-literacy adults. Copyright © 2015. Published by Elsevier B.V.

  14. Test Standard Developed for Determining the Slow Crack Growth of Advanced Ceramics at Ambient Temperature

    Science.gov (United States)

    Choi, Sung R.; Salem, Jonathan A.

    1998-01-01

    The service life of structural ceramic components is often limited by the process of slow crack growth. Therefore, it is important to develop an appropriate testing methodology for accurately determining the slow crack growth design parameters necessary for component life prediction. In addition, an appropriate test methodology can be used to determine the influences of component processing variables and composition on the slow crack growth and strength behavior of newly developed materials, thus allowing the component process to be tailored and optimized to specific needs. At the NASA Lewis Research Center, work to develop a standard test method to determine the slow crack growth parameters of advanced ceramics was initiated by the authors in early 1994 in the C 28 (Advanced Ceramics) committee of the American Society for Testing and Materials (ASTM). After about 2 years of required balloting, the draft written by the authors was approved and established as a new ASTM test standard: ASTM C 1368-97, Standard Test Method for Determination of Slow Crack Growth Parameters of Advanced Ceramics by Constant Stress-Rate Flexural Testing at Ambient Temperature. Briefly, the test method uses constant stress-rate testing to determine strengths as a function of stress rate at ambient temperature. Strengths are measured in a routine manner at four or more stress rates by applying constant displacement or loading rates. The slow crack growth parameters required for design are then estimated from a relationship between strength and stress rate. This new standard will be published in the Annual Book of ASTM Standards, Vol. 15.01, in 1998. Currently, a companion draft ASTM standard for determination of the slow crack growth parameters of advanced ceramics at elevated temperatures is being prepared by the authors and will be presented to the committee by the middle of 1998. Consequently, Lewis will maintain an active leadership role in advanced ceramics standardization within ASTM

  15. Standardization Efforts for Mechanical Testing and Design of Advanced Ceramic Materials and Components

    Science.gov (United States)

    Salem, Jonathan A.; Jenkins, Michael G.

    2003-01-01

    Advanced aerospace systems occasionally require the use of very brittle materials such as sapphire and ultra-high temperature ceramics. Although great progress has been made in the development of methods and standards for machining, testing and design of component from these materials, additional development and dissemination of standard practices is needed. ASTM Committee C28 on Advanced Ceramics and ISO TC 206 have taken a lead role in the standardization of testing for ceramics, and recent efforts and needs in standards development by Committee C28 on Advanced Ceramics will be summarized. In some cases, the engineers, etc. involved are unaware of the latest developments, and traditional approaches applicable to other material systems are applied. Two examples of flight hardware failures that might have been prevented via education and standardization will be presented.

  16. Standard test method for laboratory evaluation of magnesium sacrificial anode test specimens for underground applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a laboratory procedure that measures the two fundamental performance properties of magnesium sacrificial anode test specimens operating in a saturated calcium sulfate, saturated magnesium hydroxide environment. The two fundamental properties are electrode (oxidation potential) and ampere hours (Ah) obtained per unit mass of specimen consumed. Magnesium anodes installed underground are usually surrounded by a backfill material that typically consists of 75 % gypsum (CaSO4·2H2O), 20 % bentonite clay, and 5 % sodium sulfate (Na2SO4). The calcium sulfate, magnesium hydroxide test electrolyte simulates the long term environment around an anode installed in the gypsum-bentonite-sodium sulfate backfill. 1.2 This test method is intended to be used for quality assurance by anode manufacturers or anode users. However, long term field performance properties may not be identical to property measurements obtained using this laboratory test. Note 1—Refer to Terminology G 15 for terms used ...

  17. Standard test method for radiochemical determination of uranium isotopes in urine by alpha spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method is applicable to the determination of uranium in urine at levels of detection dependent on sample size, count time, detector background, and tracer yield. It is designed as a screening tool for detection of possible exposure of occupational workers. 1.2 This test method is designed for 50 mL of urine. This test method does not address the sampling protocol or sample preservation methods associated with its use. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  18. Test of "Light" Cigarette Counter-Advertising Using a Standard Test of Advertising Effectiveness

    National Research Council Canada - National Science Library

    Saul Shiffman; Steven L. Burton; Janine L. Pillitteri; Joe G. Gitchell; Michael E. Di Marino; Christine T. Sweeney; Paul A. Wardle; Gary L. Koehler

    2001-01-01

    ...), or promotion of branded NRT). The effectiveness of each advertisement was determined using a validated advertising testing system in which ads were viewed in the context of reviewing a pilot television programme...

  19. Pharmacy students' test-taking motivation-effort on a low-stakes standardized test.

    Science.gov (United States)

    Waskiewicz, Rhonda A

    2011-04-11

    To measure third-year pharmacy students' level of motivation while completing the Pharmacy Curriculum Outcomes Assessment (PCOA) administered as a low-stakes test to better understand use of the PCOA as a measure of student content knowledge. Student motivation was manipulated through an incentive (ie, personal letter from the dean) and a process of statistical motivation filtering. Data were analyzed to determine any differences between the experimental and control groups in PCOA test performance, motivation to perform well, and test performance after filtering for low motivation-effort. Incentivizing students diminished the need for filtering PCOA scores for low effort. Where filtering was used, performance scores improved, providing a more realistic measure of aggregate student performance. To ensure that PCOA scores are an accurate reflection of student knowledge, incentivizing and/or filtering for low motivation-effort among pharmacy students should be considered fundamental best practice when the PCOA is administered as a low-stakes test.

  20. 40 CFR 79.60 - Good laboratory practices (GLP) standards for inhalation exposure health effects testing.

    Science.gov (United States)

    2010-07-01

    ... exposure health effects testing. (a) General Provisions—(1) Scope. (i) This section prescribes good... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Good laboratory practices (GLP) standards for inhalation exposure health effects testing. 79.60 Section 79.60 Protection of Environment...

  1. Consensus based reporting standards for diagnostic test accuracy studies for paratuberculosis in ruminants.

    NARCIS (Netherlands)

    Gardner, I.A.; Nielsen, S.S.; Whittington, R.J.; Collins, M.T.; Bakker, D.; Harris, B.; Sreevatsan, S.; Lombard, J.E.; Sweeney, R.; Smith, D.R.; Gavalchin, J.; Eda, S.

    2011-01-01

    The Standards for Reporting of Diagnostic Accuracy (STARD) statement (www.stard-statement.org) was developed to encourage complete and transparent reporting of key elements of test accuracy studies in human medicine. The statement was motivated by widespread evidence of bias in test accuracy studies

  2. Space and Missile Systems Center Standard: Test Requirements for Ground Systems

    Science.gov (United States)

    2013-09-30

    test levels used in this standard, which should be translated and tailored for the levels and terms of a specific program. The test requirements...should not be confused with the analysis method described here. Bug (software): Common and traditional slang for a defect in software syntax or logic

  3. Fairness Issues in a Standardized English Test for Nonnative Speakers of English

    Science.gov (United States)

    Puspawati, Indah

    2014-01-01

    For nonnative English speakers, taking a standardized English proficiency test seems inevitable, because the scores achieved play an important role in such life events as admission to a school, gaining a scholarship, or securing a job. Considering their importance, it is imperative that such tests be not only valid and reliable, but also fair.…

  4. Development of a Standard Test to Assess the Resistance of Staphylococcus aureus Biofilm Cells to Disinfectants

    NARCIS (Netherlands)

    Luppens, S.B.I.; Reij, M.W.; Heijden, van der R.W.; Rombouts, F.M.; Abee, T.

    2002-01-01

    A standardized disinfectant test for Staphylococcus aureus cells in biofilms was developed. Two disinfectants, the membrane-active compound benzalkonium chloride (BAC) and the oxidizing agent sodium hypochlorite, were used to evaluate the biofilm test. S. aureus formed biofilms on glass, stainless

  5. Validation of Criterion-Referenced Standards for Tests of Arm and Shoulder Girdle Strength and Endurance.

    Science.gov (United States)

    Rutherford, William J.; Corbin, Charles B.

    1994-01-01

    This study established criterion-referenced standards for selected tests of arm and shoulder girdle strength and endurance in college females. Tests of trained and untrained students using the contrasting groups method yielded criterion cutoff scores that classified subjects as trained or untrained based on upper arm and shoulder girdle resistance…

  6. Comparing the Effects of Elementary Music and Visual Arts Lessons on Standardized Mathematics Test Scores

    Science.gov (United States)

    King, Molly Elizabeth

    2016-01-01

    The purpose of this quantitative, causal-comparative study was to compare the effect elementary music and visual arts lessons had on third through sixth grade standardized mathematics test scores. Inferential statistics were used to compare the differences between test scores of students who took in-school, elementary, music instruction during the…

  7. The Inter Facility Testing of a Standard Oscillating Water Column (OWC) Type Wave Energy Converter (WEC)

    DEFF Research Database (Denmark)

    Andersen, Morten Thøtt; Thomsen, Jonas Bjerg

    This report describes the behavior and preliminary performance of a simplified standard oscillating water column (OWC) wave energy converter (WEC). The same tests will be conducted at different scales at 6 different test facilities and the results obtained will be used for comparison. This project...

  8. The Impact of Intensive Reading Interventions on Student Standardized Test Scores

    Science.gov (United States)

    Munoz, Carolyn Sue

    2010-01-01

    The purpose of this study was to identify the impact intensive reading instruction had for 28 students with learning disabilities at the middle school level on standardized tests. National Assessment of Education Progress testing indicates that across the United States, learning disabled students literacy skills are decreasing annually, and these…

  9. Standard test method for determination of surface lubrication on flexible webs

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method has been used since 1988 as an ANSI/ISO standard test for determination of lubrication on processed photographic films. Its purpose was to determine the presence of process-surviving lubricants on photographic films. It is the purpose of this test method to expand the applicability of this test method to other flexible webs that may need lubrication for suitable performance. This test measures the breakaway (static) coefficient of friction of a metal rider on the web by the inclined plane method. The objectives of the test is to determine if a web surface has a lubricant present or not. It is not intended to assign a friction coefficient to a material. It is not intended to rank lubricants. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish ...

  10. Proceedings of the Advisory Committee on standardization of carbon-phenolic test methods and specifications

    Science.gov (United States)

    Hall, William B.

    1991-01-01

    Proceedings of the Advisory Committee on Standardization of carbon-phenolic test methods and specifications are compiled. The following subject areas are covered: ashing procedures and alkali metal content of carbon fiber and fabrics; SPIP product identification code; SPIP initiative to adopt a water-soluble rayon yarn lubricant/size for weaving; fabric oxidation mass loss test; shelf life limit for prepregs, industry standard; silicon contamination update; resin, filler, and fabric content in prepreg; carbon assay testing calibration; thiokol rayon specifications; and SPIP low conductivity PAN program.

  11. A Multi-Year Plan for Research, Development, and Prototype Testing of Standard Modular Hydropower Technology

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Brennan T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Welch, Tim [U.S. Department of Energy (DOE), Washington, DC (United States).Office of Energy Efficiency and Renewable Energy (EERE); Witt, Adam M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Stewart, Kevin M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Lee, Kyutae [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); DeNeale, Scott T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bevelhimer, Mark S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Burress, Timothy A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Pracheil, Brenda M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Pries, Jason L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); O' Connor, Patrick W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Curd, Shelaine L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ekici, Kivanc [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Univ. of Tennessee, Knoxville, TN (United States); Papanicolaou, Thanos [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Univ. of Tennessee, Knoxville, TN (United States); Tsakiris, Achilleas [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Univ. of Tennessee, Knoxville, TN (United States); Kutz, Benjamin [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Univ. of Tennessee, Knoxville, TN (United States); Bishop, Norm [Knight Piesold, Denver, CO (United States); McKeown, Alisha [McKeown and Associates, Moberly, MO (United States); Rabon, Daniel [U.S. Department of Energy (DOE), Washington, DC (United States).Office of Energy Efficiency and Renewable Energy (EERE); Zimmerman, Gregory P. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Uria Martinez, Rocio [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); McManamay, Ryan A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-02-01

    The Multi-Year Plan for Research, Development, and Prototype Testing of Standard Modular Hydropower Technology (MYRP) presents a strategy for specifying, designing, testing, and demonstrating the efficacy of standard modular hydropower (SMH) as an environmentally compatible and cost-optimized renewable electricity generation technology. The MYRP provides the context, background, and vision for testing the SMH hypothesis: if standardization, modularity, and preservation of stream functionality become essential and fully realized features of hydropower technology, project design, and regulatory processes, they will enable previously unrealized levels of new project development with increased acceptance, reduced costs, increased predictability of outcomes, and increased value to stakeholders. To achieve success in this effort, the MYRP outlines a framework of stakeholder-validated criteria, models, design tools, testing facilities, and assessment protocols that will facilitate the development of next-generation hydropower technologies.

  12. Development of a standardized battery of performance tests for the assessment of noise stress effects

    Science.gov (United States)

    Theologus, G. C.; Wheaton, G. R.; Mirabella, A.; Brahlek, R. E.

    1973-01-01

    A set of 36 relatively independent categories of human performance were identified. These categories encompass human performance in the cognitive, perceptual, and psychomotor areas, and include diagnostic measures and sensitive performance metrics. Then a prototype standardized test battery was constructed, and research was conducted to obtain information on the sensitivity of the tests to stress, the sensitivity of selected categories of performance degradation, the time course of stress effects on each of the selected tests, and the learning curves associated with each test. A research project utilizing a three factor partially repeated analysis of covariance design was conducted in which 60 male subjects were exposed to variations in noise level and quality during performance testing. Effects of randomly intermittent noise on performance of the reaction time tests were observed, but most of the other performance tests showed consistent stability. The results of 14 analyses of covariance of the data taken from the performance of the 60 subjects on the prototype standardized test battery provided information which will enable the final development and test of a standardized test battery and the associated development of differential sensitivity metrics and diagnostic classificatory system.

  13. CPM Test-Retest Reliability: "Standard" vs "Single Test-Stimulus" Protocols.

    Science.gov (United States)

    Granovsky, Yelena; Miller-Barmak, Adi; Goldstein, Oren; Sprecher, Elliot; Yarnitsky, David

    2016-03-01

    Assessment of pain inhibitory mechanisms using conditioned pain modulation (CPM) is relevant clinically in prediction of pain and analgesic efficacy. Our objective is to provide necessary estimates of intersession CPM reliability, to enable transformation of the CPM paradigm into a clinical tool. Two cohorts of young healthy subjects (N = 65) participated in two dual-session studies. In Study I, a Bath-Thermode CPM protocol was used, with hot water immersion and contact heat as conditioning- and test-stimuli, respectively, in a classical parallel CPM design introducing test-stimulus first, and then the conditioning- and repeated test-stimuli in parallel. Study II consisted of two CPM protocols: 1) Two-Thermodes, one for each of the stimuli, in the same parallel design as above, and 2) single test-stimulus (STS) protocol with a single administration of a contact heat test-stimulus, partially overlapped in time by a remote shorter contact heat as conditioning stimulus. Test-retest reliability was assessed within 3-7 days. The STS-CPM had superior reliability intraclass correlation (ICC2 ,: 1 = 0.59) over Bath-Thermode (ICC2 ,: 1 = 0.34) or Two-Thermodes (ICC2 ,: 1 = 0.21) protocols. The hand immersion conditioning pain had higher reliability than thermode pain (ICC2 ,: 1 = 0.76 vs ICC2 ,: 1 = 0.16). Conditioned test-stimulus pain scores were of good (ICC2 ,: 1 = 0.62) or fair (ICC2 ,: 1 = 0.43) reliability for the Bath-Thermode and the STS, respectively, but not for the Two-Thermodes protocol (ICC2 ,: 1 = 0.20). The newly developed STS-CPM paradigm was more reliable than other CPM protocols tested here, and should be further investigated for its clinical relevance. It appears that large contact size of the conditioning-stimulus and use of single rather than dual test-stimulus pain contribute to augmentation of CPM reliability. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. Standard Test Method for Measuring Dose for Use in Linear Accelerator Pulsed Radiation Effects Tests

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers a calorimetric measurement of the total dose delivered in a single pulse of electrons from an electron linear accelerator or a flash X-ray machine (FXR, e-beam mode) used as an ionizing source in radiation-effects testing. The test method is designed for use with pulses of electrons in the energy range from 10 to 50 MeV and is only valid for cases in which both the calorimeter and the test specimen to be irradiated are“thin” compared to the range of these electrons in the materials of which they are constructed. 1.2 The procedure described can be used in those cases in which (1) the dose delivered in a single pulse is 5 Gy (matl) (500 rd (matl)) or greater, or (2) multiple pulses of a lower dose can be delivered in a short time compared to the thermal time constant of the calorimeter. Matl refers to the material of the calorimeter. The minimum dose per pulse that can be acceptably monitored depends on the variables of the particular test, including pulse rate, pulse uniformity...

  15. Harmonization of standards for parabolic trough collector testing in solar thermal power plants

    Science.gov (United States)

    Sallaberry, Fabienne; Valenzuela, Loreto; Palacin, Luis G.; Leon, Javier; Fischer, Stephan; Bohren, Andreas

    2017-06-01

    The technology of parabolic trough collectors (PTC) is used widely in concentrating Solar Power (CSP) plants worldwide. However this type of large-size collectors cannot be officially tested by an accredited laboratory and certified by an accredited certification body so far, as there is no standard adapted to its particularity, and the current published standard for solar thermal collectors are not completely applicable to them. Recently some standardization committees have been working on this technology. This paper aims to give a summary of the standardized testing methodology of large-size PTC for CSP plants, giving the physical model chosen for modeling the thermal performance of the collector in the new revision of standard ISO 9806 and the points still to be improved in the standard draft IEC 62862-3-2. In this paper, a summary of the testing validation performed on one parabolic trough collector installed in one of the test facilities at the Plataforma Solar de Almería (PSA) with this new model is also presented.

  16. Electromagnetic compatibility (EMC) standard test chamber upgrade requirements for spacecraft design verification tests

    Science.gov (United States)

    Dyer, Edward F.

    1992-01-01

    In view of the serious performance deficiencies inherent in conventional modular and welded shielding EMC test enclosures, in which multipath reflections and resonant standing waves can damage flight hardware during RF susceptibility tests, NASA-Goddard has undertaken the modification of a 20 x 24 ft modular-shielded enclosure through installation of steel panels to which ferrite tiles will be mounted with epoxy. The internally reflected RF energy will thereby be absorbed, and exterior power-line noise will be reduced. Isolation of power-line filters and control of 60-Hz ground connections will also be undertaken in the course of upgrading.

  17. Standardized dirts for testing the efficacy of workplace cleaning products: validation of their workplace relevance.

    Science.gov (United States)

    Elsner, Peter; Seyfarth, Florian; Sonsmann, Flora; Strunk, Meike; John, Swen-Malte; Diepgen, Thomas; Schliemann, Sibylle

    2013-10-01

    In order to assess the cleaning efficacy of occupational skin cleansers, standardized test dirts mimicking the spectrum of skin soiling at dirty workplaces are necessary. To validate newly developed standardized test dirts (compliant with the EU Cosmetics Directive) for their occupational relevance. In this single-blinded, monocentric questionnaire-based clinical trial, 87 apprentices of three trades (household management; house painting and varnishing; and metal processing) evaluated the cleanability of six standardized test dirts in relation to their workplace dirts. In addition, they judged the similarity of the test dirts to actual dirts encountered in their working environments. Most of the household management participants assessed the hydrophilic model dirt ('mascara'), the lipophilic model dirt ('W/O cream') and a film-forming model dirt ('disperse paint') as best resembling the dirts found at their workplaces. Most of the painters and varnishers judged the filmogenic model dirts ('disperse paint' and 'acrylic paint') as best resembling the dirts found at their workplaces. For the metal workers, the lipophilic and paste-like model dirts were most similar to their workplace dirts. The spectrum of standardized test dirts developed represents well the dirts encountered at various workplaces. The test dirts may be useful in the development and in vivo efficacy testing of occupational skin cleansers. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Contribution of thermal–hydraulic validation tests to the standard design approval of SMART

    Directory of Open Access Journals (Sweden)

    Hyun-Sik Park

    2017-10-01

    Full Text Available Many thermal–hydraulic tests have been conducted at the Korea Atomic Energy Research Institute for verification of the SMART (System-integrated Modular Advanced ReacTor design, the standard design approval of which was issued by the Korean regulatory body. In this paper, the contributions of these tests to the standard design approval of SMART are discussed. First, an integral effect test facility named VISTA-ITL (Experimental Verification by Integral Simulation of Transients and Accidents-Integral Test Loop has been utilized to assess the TASS/SMR-S (Transient and Set-point Simulation/Small and Medium safety analysis code and confirm its conservatism, to support standard design approval, and to construct a database for the SMART design optimization. In addition, many separate effect tests have been performed. The reactor internal flow test has been conducted using the SCOP (SMART COre flow distribution and Pressure drop test facility to evaluate the reactor internal flow and pressure distributions. An ECC (Emergency Core Coolant performance test has been carried out using the SWAT (SMART ECC Water Asymmetric Two-phase choking test facility to evaluate the safety injection performance and to validate the thermal–hydraulic model used in the safety analysis code. The Freon CHF (Critical Heat Flux test has been performed using the FTHEL (Freon Thermal Hydraulic Experimental Loop facility to construct a database from the 5 × 5 rod bundle Freon CHF tests and to evaluate the DNBR (Departure from Nucleate Boiling Ratio model in the safety analysis and core design codes. These test results were used for standard design approval of SMART to verify its design bases, design tools, and analysis methodology.

  19. Standardization of HER2 testing: results of an international proficiency-testing ring study

    NARCIS (Netherlands)

    Dowsett, Mitch; Hanna, Wedad M.; Kockx, Mark; Penault-Llorca, Frederique; Rüschoff, Josef; Gutjahr, Thorsten; Habben, Kai; van de Vijver, Marc J.

    2007-01-01

    Human epidermal growth factor receptor 2 (HER2) positivity in breast cancer is a prognostic factor regarding tumor aggressiveness and a predictive factor for response to trastuzumab (Herceptin). Early and accurate HER2 testing of all breast cancer patients at primary diagnosis is essential for

  20. Standard Test Method for Hot Spot Protection Testing of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method provides a procedure to determine the ability of a photovoltaic (PV) module to endure the long-term effects of periodic “hot spot” heating associated with common fault conditions such as severely cracked or mismatched cells, single-point open circuit failures (for example, interconnect failures), partial (or non-uniform) shadowing or soiling. Such effects typically include solder melting or deterioration of the encapsulation, but in severe cases could progress to combustion of the PV module and surrounding materials. 1.2 There are two ways that cells can cause a hot spot problem; either by having a high resistance so that there is a large resistance in the circuit, or by having a low resistance area (shunt) such that there is a high-current flow in a localized region. This test method selects cells of both types to be stressed. 1.3 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method....

  1. Standard Test Method for Measuring Heat-Transfer Rate Using a Thermal Capacitance (Slug) Calorimeter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method describes the measurement of heat transfer rate using a thermal capacitance-type calorimeter which assumes one-dimensional heat conduction into a cylindrical piece of material (slug) with known physical properties. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. Note 1—For information see Test Methods E 285, E 422, E 458, E 459, and E 511.

  2. Standard test method for measurement of oxidation-reduction potential (ORP) of soil

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers a procedure and related test equipment for measuring oxidation-reduction potential (ORP) of soil samples removed from the ground. 1.2 The procedure in Section 9 is appropriate for field and laboratory measurements. 1.3 Accurate measurement of oxidation-reduction potential aids in the analysis of soil corrosivity and its impact on buried metallic structure corrosion rates. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Tests of local Lorentz invariance violation of gravity in the standard model extension with pulsars.

    Science.gov (United States)

    Shao, Lijing

    2014-03-21

    The standard model extension is an effective field theory introducing all possible Lorentz-violating (LV) operators to the standard model and general relativity (GR). In the pure-gravity sector of minimal standard model extension, nine coefficients describe dominant observable deviations from GR. We systematically implemented 27 tests from 13 pulsar systems to tightly constrain eight linear combinations of these coefficients with extensive Monte Carlo simulations. It constitutes the first detailed and systematic test of the pure-gravity sector of minimal standard model extension with the state-of-the-art pulsar observations. No deviation from GR was detected. The limits of LV coefficients are expressed in the canonical Sun-centered celestial-equatorial frame for the convenience of further studies. They are all improved by significant factors of tens to hundreds with existing ones. As a consequence, Einstein's equivalence principle is verified substantially further by pulsar experiments in terms of local Lorentz invariance in gravity.

  4. Standard Test Method for Bond Strength of Ceramic Tile to Portland Cement Paste

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the ability of glazed ceramic wall tile, ceramic mosaic tile, quarry tile, and pavers to be bonded to portland cement paste. This test method includes both face-mounted and back-mounted tile. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Standard test method for measurement of web/roller friction characteristics

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This test method covers the simulation of a roller/web transport tribosystem and the measurement of the static and kinetic coefficient of friction of the web/roller couple when sliding occurs between the two. The objective of this test method is to provide users with web/roller friction information that can be used for process control, design calculations, and for any other function where web/roller friction needs to be known. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. Standard Test Method for Gravimetric Determination of Nonvolatile Residue From Cleanroom Wipers

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers the determination of solvent extractable nonvolatile residue (NVR) from wipers used in assembly, cleaning, or testing of spacecraft, but not from those used for analytical surface sampling of hardware. 1.2 The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard. 1.3 The NVR of interest is that which can be extracted from cleanroom wipers using a specified solvent that has been selected for its extractive qualities. Alternative solvents may be selected, but since their use may result in different values being generated, they must be identified in the procedure data sheet. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. Standard Test Method for Gravimetric Determination of Nonvolatile Residue (NVR) in Environmentally Controlled Areas for Spacecraft

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the determination of nonvolatile residue (NVR) fallout in environmentally controlled areas used for the assembly, testing, and processing of spacecraft. 1.2 The NVR of interest is that which is deposited on sampling plate surfaces at room temperature: it is left to the user to infer the relationship between the NVR found on the sampling plate surface and that found on any other surfaces. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

  8. Performance testing of HEPA filters: Progress towards a European standard procedure

    Energy Technology Data Exchange (ETDEWEB)

    Dyment, J.

    1997-08-01

    Proposals for a future European testing procedure for {open_quotes}High Efficiency Particulate Air Filters (HEPA and ULPA){close_quotes} are being developed by CEN (Comite Europeen de Normalisation). The new standard will be given the status of national standard in participating countries, conflicting national standards being withdrawn. The standard will comprise 5 parts covering the grouping and classification of HEPA and ULPA filters according to their efficiency, fundamental principles of testing, marking etc (in part 1). Part 2 will cover aerosol production, measurement principles, counting equipment and statistics. Parts 3-5 will cover testing flat sheet media, leak testing of filter elements and the efficiency testing of filter elements respectively. The efficiency test methods allow the use of either homogeneous monodisperse or polydisperse aerosols for the determination of particulate filtration efficiencies as a function of particle size. The particle size at which maximum penetration occurs is first determined in flat sheet media tests; tests on filter elements (constructed using the same filter medium) may be carried out using either a homogeneous monodisperse aerosol of the size at which maximum penetration occurs (MPPS) or a polydisperse aerosol whose median size is close to the MPPS. Tests with monodisperse aerosols may be conducted using condensation nucleus counting equipment; tests using polydisperse test aerosols require the use of optical sizing particle counters. When determining the efficiency of filter elements the downstream aerosol concentrations may be determined from air samples obtained using either an overall method (single point sampling after mixing) or a scan method. The scan method also allows {open_quotes}local{close_quotes} efficiency values to be determined. 1 ref., 1 fig., 1 tab.

  9. Standard Test Method for Solar Photometric Transmittance of Sheet Materials Using Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This test method covers the measurement of solar photometric transmittance of materials in sheet form. Solar photometric transmittance is measured using a photometer (illuminance meter) in an enclosure with the sun and sky as the source of radiation. The enclosure and method of test is specified in Test Method E 1175 (or Test Method E 1084). 1.2 The purpose of this test method is to specify a photometric sensor to be used with the procedure for measuring the solar photometric transmittance of sheet materials containing inhomogeneities in their optical properties. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Standard Test Method for Resin Flow of Carbon Fiber-Epoxy Prepreg

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers the determination of the amount of resin flow that will take place from prepreg tape or sheet under given conditions of temperature and pressure. 1.2 The values stated in SI units are to be regarded as standard. The values in parentheses are for reference only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. Standard test method for measurement of soil resistivity using the two-electrode soil box method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the equipment and a procedure for the measurement of soil resistivity, for samples removed from the ground, for use in the control of corrosion of buried structures. 1.2 Procedures allow for this test method to be used n the field or in the laboratory. 1.3 The test method procedures are for the resistivity measurement of soil samples in the saturated condition and in the as-received condition. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. Soil resistivity values are reported in ohm-centimeter. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  12. Toward the establishment of standardized in vitro tests for lipid-based formulations, part 4

    DEFF Research Database (Denmark)

    Williams, Hywel D; Sassene, Philip; Kleberg, Karen

    2014-01-01

    The Lipid Formulation Classification System Consortium looks to develop standardized in vitro tests and to generate much-needed performance criteria for lipid-based formulations (LBFs). This article highlights the value of performing a second, more stressful digestion test to identify LBFs near...... a performance threshold and to facilitate lead formulation selection in instances where several LBF prototypes perform adequately under standard digestion conditions (but where further discrimination is necessary). Stressed digestion tests can be designed based on an understanding of the factors that affect LBF......-chain glyceride-rich LBFs, but not more hydrophilic surfactant-rich LBFs, whereas decreasing pH stressed tolfenamic acid LBFs, but not fenofibrate LBFs. Lastly, a new Performance Classification System, that is, LBF composition independent, is proposed to promote standardized LBF comparisons, encourage robust LBF...

  13. The equivalence of multi-axis spine systems: Recommended stiffness limits using a standardized testing protocol.

    Science.gov (United States)

    Holsgrove, Timothy P; Amin, Dhara B; Pascual, Sonia Ramos; Ding, Boyin; Welch, William C; Gheduzzi, Sabina; Miles, Anthony W; Winkelstein, Beth A; Costi, John J

    2017-09-14

    The complexity of multi-axis spine testing often makes it challenging to compare results from different studies. The aim of this work was to develop and implement a standardized testing protocol across three six-axis spine systems, compare them, and provide stiffness and phase angle limits against which other test systems can be compared. Standardized synthetic lumbar specimens (n=5), comprising three springs embedded in polymer at each end, were tested on each system using pure moments in flexion-extension, lateral bending, and axial rotation. Tests were performed using sine and triangle waves with an amplitude of 8Nm, a frequency of 0.1Hz, and with axial preloads of 0 and 500N. The stiffness, phase angle, and R2 value of the moment against rotation in the principal axis were calculated at the center of each specimen. The tracking error was adopted asa measure of each test system to minimize non-principal loads, defined as the root mean squared difference between actual and target loads. All three test systems demonstrated similar stiffnesses, with small (systems. These recommendations can be used with the standard specimen and testing protocol by other research institutions to ensure equivalence of different spine systems, increasing the ability to compare in vitro spine studies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Prevalence of Exercise-Induced Bronchoconstriction Measured by Standardized Testing in Healthy College Athletes.

    Science.gov (United States)

    Burnett, David M; Burns, Steve; Merritt, Samantha; Wick, Jo; Sharpe, Matthew

    2016-05-01

    Exercise-induced bronchoconstriction (EIB) can lead to long-term respiratory illness and even death. EIB prevalence rates are both high and variable in college athletes. Prevalence rates may be underestimated due to ineffective testing and screening. The purpose of this study was to investigate the prevalence of EIB in college athletes by a standardized EIB test that can be used on many college campuses. In addition, we assessed the usefulness of self-reporting EIB/asthma (1) history, (2) symptoms, and (3) respiratory medication obtained from a simple screening questionnaire for predicting an EIB-positive athlete. A standardized EIB test and self-report questionnaire were administered to college athletes on 10 different sports teams. Information collected included pulmonary function (spirometry), expired gas analysis (maximal oxygen uptake), CO2 production, minute ventilation, EIB/asthma history, current symptoms, and medication use. Results showed that 34 of 80 athletes (42.5%) were EIB-positive by standardized exercise testing. The majority (76.5 and 58.8%) of the 34 athletes who tested positive self-reported a negative history or no symptoms, respectively. Also, 79.4% of the athletes who tested positive for EIB reported not using a respiratory medication. There were no significant differences in a positive EIB test when assessing interactions for history (P = .93), current symptoms (P = .12), or respiratory medication use (P = .66). A high proportion of college athletes tested positive for EIB when using a standardized test. Positive history, current symptoms of EIB/asthma, and respiratory medication use were not predictive of a positive test. Many EIB-positive athletes are not using a respiratory medication. More work is needed to develop an effective screening tool and improve education for EIB in college athletes. Copyright © 2016 by Daedalus Enterprises.

  15. Decision support for acute problems: the role of the standardized patient in usability testing.

    Science.gov (United States)

    Linder, Jeffrey A; Rose, Alan F; Palchuk, Matvey B; Chang, Frank; Schnipper, Jeffrey L; Chan, Joseph C; Middleton, Blackford

    2006-12-01

    For applications that require clinician use while interacting with patients, usability testing with standardized patients has the potential to approximate actual patient care in a controlled setting. We used hypothetical scenarios and a standardized patient to collect quantitative and qualitative results in testing an early prototype of a new application, the Acute Respiratory Infection (ARI) Smart Form. The standardized patient fit well into the usability testing sessions. Clinicians had a positive response to the standardized patients and behaved as they normally would during a clinical encounter. Positive findings of the ARI Smart Form included that users thought it had impressive functionality and the potential to save time. Criticism focused on the visual design, which could be streamlined, and navigation, which was difficult in some areas. Based on these results, we are modifying the ARI Smart Form in preparation for use in actual patient care. Standardized patients should be considered for usability testing, especially if an application is to be used during the patient interview.

  16. Termite-Susceptible Species of Wood for Inclusion as a Reference in Indonesian Standardized Laboratory Testing.

    Science.gov (United States)

    Arinana; Tsunoda, Kunio; Herliyana, Elis N; Hadi, Yusuf S

    2012-03-28

    Standardized laboratory testing of wood and wood-based products against subterranean termites in Indonesia (SNI 01.7207-2006) (SNI) has no requirement for the inclusion of a comparative reference species of wood (reference control). This is considered a weakness of the Indonesian standard. Consequently, a study was undertaken to identify a suitable Indonesian species of community wood that could be used as a reference control. Four candidate species of community woods: Acacia mangium, Hevea brasiliensis, Paraserianthes falcataria and Pinus merkusii were selected for testing their susceptibility to feeding by Coptotermes formosanus. Two testing methods (SNI and the Japanese standard method JIS K 1571-2004) were used to compare the susceptibility of each species of wood. Included in the study was Cryptomeria japonica, the reference control specified in the Japanese standard. The results of the study indicated that P. merkusii is a suitable reference species of wood for inclusion in laboratory tests against subterranean termites, conducted in accordance with the Indonesian standard (SNI 01.7207-2006).

  17. Development of a standardized procedure for testing the efficacy of workplace cleansers.

    Science.gov (United States)

    Elsner, Peter; Seyfarth, Florian; Sonsmann, Flora; John, Swen-Malte; Diepgen, Thomas; Schliemann, Sibylle

    2014-01-01

    Occupational skin cleansing is a risk factor for cumulative irritant dermatitis. Standardized methods are required to assess the cleaning efficacy of occupational skin cleansers, allowing us to choose the optimal cleanser with minimal irritation for specific workplaces. To develop a standardized procedure for testing the cleaning efficacy of occupational skin cleansers. In this single-blind, randomized, monocentric clinical trial in 24 healthy volunteers, the cleaning efficacy of generic reference cleansers was assessed against standardized test dirts. The test procedure included standardized dirt application, standardized washing with an automated skin cleaning device, and quantification of the cleaning efficacy by chromametry. For two cleansers, reproducibility of the cleaning efficacy assessment was studied. Furthermore, the performance of two cleansers was compared with that of commercial skin cleansers. Cleaning factors ranged from 12% up to 97% for the respective model dirts. A high reproducibility of the washing and the assessment procedure could be shown. The comparison of the washing efficacies for two reference cleansers with those of commercial cleansers showed partly similar performances, but also a higher cleaning efficacy for some dirts of the reference cleansers. The testing procedure proved to be applicable to a wide spectrum of cleansers and model dirts. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. 40 CFR 85.2203 - Short test standards for 1981 and later model year light-duty vehicles.

    Science.gov (United States)

    2010-07-01

    ... Control System Performance Warranty Short Tests § 85.2203 Short test standards for 1981 and later model... 1982 and later model year vehicles at high altitude to which high altitude certification standards of 1... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Short test standards for 1981 and...

  19. Test of "Light" cigarette counter-advertising using a standard test of advertising effectiveness.

    Science.gov (United States)

    Shiffman, S; Burton, S L; Pillitteri, J L; Gitchell, J G; Di Marino, M E; Sweeney, C T; Wardle, P A; Koehler, G L

    2001-01-01

    To evaluate systematically the effectiveness of six advertising strategies (two message strategies presented in three different contexts) designed to promote smoking cessation by addressing smokers' misperceptions about Light cigarettes. Smokers viewed one of six, 30 second test television concept advertisements, which varied by message (one emphasising how the sensory effects of Lights can be deceptive, the other describing the effects of vent blocking) and by ad context (non-commercial public service announcement (PSA), promotion of unbranded nicotine replacement therapy (NRT), or promotion of branded NRT). The effectiveness of each advertisement was determined using a validated advertising testing system in which ads were viewed in the context of reviewing a pilot television programme. Response to ads is assessed through shifts in subject choices of products offered as prizes before and after viewing the test advertisements. Included among the possible prizes were cigarettes and various pharmacotherapies for smoking cessation. Daily smokers (n = 1890) of Regular (34%), Light (47%), and Ultra Light (19%) cigarettes recruited from eight US cities. The primary outcome of interest was the shift away from cigarettes as the selected prize following exposure to the test advertisements. Secondary outcomes of interest included movement away from Light cigarettes and movement towards assisted quitting products. Smokers who saw the advertisement emphasising the sensory characteristics of Light cigarettes were more likely than subjects who saw the advertisement emphasising the effect of vent blocking to move away from cigarettes (OR = 1.97, 95% confidence interval CI 1.25 to 3.09; chi(2)(1) = 8.69, p = 0.003). Similarly, subjects who saw the advertisement framed as a PSA, rather than as a promotion for either a branded or unbranded NRT product, were also somewhat more likely to move away from cigarettes (OR = 1.51, 95% CI 0.94 to 2.40; chi(2)(1) = 2.97, p = 0.085). The

  20. Non-standard tests for process control in chemically bonded sands

    Directory of Open Access Journals (Sweden)

    S. Ramrattan

    2016-01-01

    Full Text Available Chemically bonded sand cores and molds are more commonly referred to as precision sand systems in the high production automotive powertrain sector. Their behavior in contact with molten metal can lead to casting defects. Consequently, the interaction is of great interest and an important part of metal casting technology. The American Foundry Society (AFS sand testing is based on physical, mechanical, thermal and chemical properties of the sand system. Foundry engineers have long known that certain AFS sand tests provide limited information regarding control of molding and casting quality. The inadequacy is due to the fact that sand casting processes are inherently thermo-mechanical, thermo-chemical and thermo-physical. Non-standard foundry sand testing has proven useful for laboratory measurement of these characteristics in foundry sand using a disc-shaped specimen. Similarly, the equivalent disc-shaped specimens are used for casting trials. In order to accomplish near-net-shape casting with minimal defects, it is necessary to understand both the properties of the sand system, as well as the interface of molten metal when different binders, additives and/or refractory coatings are used. The methodology for the following non-standard chemically bonded sand tests is described: (1 disc transverse; (2 impact; (3 modified permeability; (4 abrasion; (5 thermal distortion; (6 quick loss on ignition. The data related to the non-standard sand tests were analyzed and interpreted. The test results indicate that there is relatively lower test-to-test variability with the disc-shaped specimens. The non-standard tests were able to discriminate between the chemically bonded polyurethane cold box sand specimens. Further studies should be conducted on various other sand and binder systems as well as on different specimen thicknesses.

  1. A comparative appraisal of two equivalence tests for multiple standardized effects.

    Science.gov (United States)

    Shieh, Gwowen

    2016-04-01

    Equivalence testing is recommended as a better alternative to the traditional difference-based methods for demonstrating the comparability of two or more treatment effects. Although equivalent tests of two groups are widely discussed, the natural extensions for assessing equivalence between several groups have not been well examined. This article provides a detailed and schematic comparison of the ANOVA F and the studentized range tests for evaluating the comparability of several standardized effects. Power and sample size appraisals of the two grossly distinct approaches are conducted in terms of a constraint on the range of the standardized means when the standard deviation of the standardized means is fixed. Although neither method is uniformly more powerful, the studentized range test has a clear advantage in sample size requirements necessary to achieve a given power when the underlying effect configurations are close to the priori minimum difference for determining equivalence. For actual application of equivalence tests and advance planning of equivalence studies, both SAS and R computer codes are available as supplementary files to implement the calculations of critical values, p-values, power levels, and sample sizes. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. Standard test method for plutonium assay by plutonium (III) diode array spectrophotometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method describes the determination of total plutonium as plutonium(III) in nitrate and chloride solutions. The technique is applicable to solutions of plutonium dioxide powders and pellets (Test Methods C 697), nuclear grade mixed oxides (Test Methods C 698), plutonium metal (Test Methods C 758), and plutonium nitrate solutions (Test Methods C 759). Solid samples are dissolved using the appropriate dissolution techniques described in Practice C 1168. The use of this technique for other plutonium-bearing materials has been reported (1-5), but final determination of applicability must be made by the user. The applicable concentration range for plutonium sample solutions is 10–200 g Pu/L. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropria...

  3. Implementing a standardized testing program: preparing students for the NCLEX-RN.

    Science.gov (United States)

    Jacobs, Phyllis; Koehn, Mary L

    2006-01-01

    The undergraduate nursing faculty of a large Midwestern university initiated a program of standardized computerized testing for two purposes: to provide students experience with standardized computerized testing prior to taking the National Council Licensure Exam for Registered Nurses (NCLEX-RN) and to increase the students' NCLEX-RN passing rate. This article chronicles the process of implementing a comprehensive testing program developed by the Assessment Technologies Institute (Overland Park, KS). Although the first class of students to have taken the entire testing package has just graduated, midprogram results have demonstrated potential as key indicators for identifying at-risk students. The trends in scores on standardized computerized tests, grades in prerequisite science courses, and grades in medical-surgical courses are used to identify students who are at risk for failure in the program and on the NCLEX-RN. Faculty advisors meet with these students to develop individual plans of study and to provide additional resources. The testing process is going on smoothly, and faculty members are learning to use the extensive information on students' test scores to further assist them in passing the NCLEX-RN.

  4. Usage of Latent Class Analysis in Diagnostic Microbiology in the Absence of Gold Standard Test

    Directory of Open Access Journals (Sweden)

    Gul Bayram Abiha

    2016-12-01

    Full Text Available The evaluation of performance of various tests diagnostic tests in the absence of gold standard is an important problem. Latent class analysis (LCA is a statistical analysis method known for many years, especially in the absence of a gold standard for evaluation of diagnostic tests so that LCA has found its wide application area. During the last decade, LCA method has widely used in for determining sensivity and specifity of different microbiological tests. It has investigated in the diagnosis of mycobacterium tuberculosis, mycobacterium bovis, human papilloma virus, bordetella pertussis, influenza viruses, hepatitis E virus (HEV, hepatitis C virus (HCV and other various viral infections. Researchers have compared several diagnostic tests for the diagnosis of different pathogens with LCA. We aimed to evaluate performance of latent class analysis method used microbiological diagnosis in various diseases in several researches. When we took into account all of these tests' results, we suppose that LCA is a good statistical analysis method to assess different test performances in the absence of gold standard. [Archives Medical Review Journal 2016; 25(4.000: 467-488

  5. US Department of Energy DOE Nevada Operations Office, Nevada Test Site: Underground safety and health standards

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    The Nevada Test Site Underground Safety and Health Standards Working Group was formed at the direction of John D. Stewart, Director, Nevada Test Site Office in April, 1990. The objective of the Working Group was to compile a safety and health standard from the California Tunnel Safety Orders and OSHA for the underground operations at the NTS, (excluding Yucca Mountain). These standards are called the NTS U/G Safety and Health Standards. The Working Group submits these standards as a RECOMMENDATION to the Director, NTSO. Although the Working Group considers these standards to be the most integrated and comprehensive standards that could be developed for NTS Underground Operations, the intent is not to supersede or replace any relevant DOE orders. Rather the intent is to collate the multiple safety and health references contained in DOE Order 5480.4 that have applicability to NTS Underground Operations into a single safety and heath standard to be used in the underground operations at the NTS. Each portion of the standard was included only after careful consideration by the Working Group and is judged to be both effective and appropriate. The specific methods and rationale used by the Working Group are outlined as follows: The letter from DOE/HQ, dated September 28, 1990 cited OSHA and the CTSO as the safety and health codes applicable to underground operations at the NTS. These mandated codes were each originally developed to be comprehensive, i.e., all underground operations of a particular type (e.g., tunnels in the case of the CTSO) were intended to be adequately regulated by the appropriate code. However, this is not true; the Working Group found extensive and confusing overlap in the codes in numerous areas. Other subjects and activities were addressed by the various codes in cursory fashion or not at all.

  6. Correlation between strength properties in standard test specimens and molded phenolic parts

    Science.gov (United States)

    Turner, P S; Thomason, R H

    1946-01-01

    This report describes an investigation of the tensile, flexural, and impact properties of 10 selected types of phenolic molding materials. The materials were studied to see in what ways and to what extent their properties satisfy some assumptions on which the theory of strength of materials is based: namely, (a) isotropy, (b) linear stress-strain relationship for small strains, and (c) homogeneity. The effect of changing the dimensions of tensile and flexural specimens and the span-depth ratio in flexural tests were studied. The strengths of molded boxes and flexural specimens cut from the boxes were compared with results of tests on standard test specimens molded from the respective materials. The nonuniformity of a material, which is indicated by the coefficient of variation, affects the results of tests made with specimens of different sizes and tests with different methods of loading. The strength values were found to depend on the relationship between size and shape of the molded specimen and size and shape of the fillers. The most significant variations observed within a diversified group of materials were found to depend on the orientation of fibrous fillers. Of secondary importance was the dependence of the variability of test results on the pieces of filler incorporated into the molding powder as well as on the size of the piece. Static breaking strength tests on boxes molded from six representative phenolic materials correlated well with falling-ball impact tests on specimens cut from molded flat sheets. Good correlation was obtained with Izod impact tests on standard test specimens prepared from the molding materials. The static breaking strengths of the boxes do not correlate with the results of tensile or flexural tests on standard specimens.

  7. Standard test method for calibration of surface/stress measuring devices

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    Return to Contents page 1.1 This test method covers calibration or verification of calibration, or both, of surface-stress measuring devices used to measure stress in annealed and heat-strengthened or tempered glass using polariscopic or refractometry based principles. 1.2 This test method is nondestructive. 1.3 This test method uses transmitted light, and therefore, is applicable to light-transmitting glasses. 1.4 This test method is not applicable to chemically tempered glass. 1.5 Using the procedure described, surface stresses can be measured only on the “tin” side of float glass. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  8. Thermal quantitative sensory testing in healthy Dutch children and adolescents standardized test paradigm and Dutch reference values.

    Science.gov (United States)

    van den Bosch, Gerbrich E; van Dijk, Monique; Tibboel, Dick; Valkenburg, Abraham J

    2017-03-16

    Quantitative sensory testing (QST) is often used to measure children's and adults' detection- and pain thresholds in a quantitative manner. In children especially the Thermal Sensory Analyzer (TSA-II) is often applied to determine thermal detection and pain thresholds. As comparisons between studies are hampered by the different testing protocols used, we aimed to present a standard protocol and reference values for thermal detection- and pain thresholds in children. Our standard testing protocol includes reaction time dependent and independent tests and takes about 14-18 min to complete. Reference values were obtained from a sample of 69 healthy term born children and adolescents with a median age of 11.2 years (range 8.2 to 17.9 years old). Seventy-one children were recruited and data of 28 males and 41 females was obtained correctly. We studied possible age and sex differences. This study provides Dutch reference values and presents a standard quantitative sensory testing protocol for children with an age from 8 years onwards. This protocol appeared to be feasible, since only two out of 71 participants were not able to correctly complete the protocol due to attention deficits and were therefore excluded. We found some significant age and sex differences: females were statistically significantly more sensitive for both cold and heat pain compared to males, and the youngest children (8-9 years old) were less sensitive to detect a warm stimulus. The youngest children tend to be more sensitive to heat pain in comparison to older participants, although the difference was not statistically significant. We present a feasible thermal quantitative sensory testing protocol for children and reference values that are easy to interpret and may serve as normative values for future studies.

  9. Standard test method for determining nodularity and nodule count in ductile iron using image analysis

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method is used to determine the percent nodularity and the nodule count per unit area (that is, number of nodules per mm2) using a light microscopical image of graphite in nodular cast iron. Images generated by other devices, such as a scanning electron microscope, are not specifically addressed, but can be utilized if the system is calibrated in both x and y directions. 1.2 Measurement of secondary or temper carbon in other types of cast iron, for example, malleable cast iron or in graphitic tool steels, is not specifically included in this standard because of the different graphite shapes and sizes inherent to such grades 1.3 This standard deals only with the recommended test method and nothing in it should be construed as defining or establishing limits of acceptability or fitness for purpose of the material tested. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address al...

  10. New Standards for the Validation of EMC Test Sites particularly above 1 GHz

    Directory of Open Access Journals (Sweden)

    S. Battermann

    2005-01-01

    Full Text Available Standards for the validation of alternative test sites with conducting groundplane exist for the frequency range 30-1000 MHz since the end of the eighties. Recently the procedure for fully anechoic rooms (FAR has been included in CISPR 16 after more than 10 years intensive discussion in standards committees (CENELEC, 2002; CISPR, 2004. But there are no standards available for the validation of alternative test sites above 1 GHz. The responsible working group (WG1 in CISPR/A has drawn up the 7th common draft (CD. A CDV will be published in spring 2005. The German standards committee VDE AK 767.4.1 participates in the drafting of the standard. All suggested measurement procedures proposed in the last CDs have been investigated by measurements and theoretical analysis. This contribution describes the basic ideas and problems of the validation procedure of the test site. Furthermore measurement results and numerical calculations will be presented especially for the use of omni-directional antennas.

  11. Development of a standardized method for motion testing in pulse oximeters.

    Science.gov (United States)

    Shang, Allan B; Kozikowski, Raymond T; Winslow, Andrew W; Weininger, Sandy

    2007-12-01

    Pulse oximeter performance in the presence of motion varies among devices and manufacturers because of variations in hardware, software, testing, and calibration. Compounding these differences is a lack of uniform characterization of motion, and the consequential effects of motion upon the wide range of normal and abnormal human physiology. Traditional motion testing attempts to standardize motion into a reproducible form by using a mechanical jig to produce passive motion of a known amplitude and frequency. This type of motion challenge fails to account for the physiologic changes induced by active movement. We postulate that a more appropriate method for testing the performance of pulse oximeters in the presence of motion is to create a feedback control loop between the device and the test subject, providing a reproducible, actively created, and controlled motion test suitable for standardized testing among manufacturers. It is hoped that relying on a signal as seen from the oximeter's perspective will enable the creation of a sensitive and reproducible test method capable of separating those oximeters that can reject motion artifact from those that cannot. Preliminary results have concentrated on building the tools and clinical protocols needed to evaluate this method. Some basic observations are reported, but insufficient numbers of experienced subjects precludes rigorous conclusions. We have set the stage for a feasibility demonstration using a novel form of testing. With sufficient subjects and proper statistical evaluation, a robust test method for assessing the performance of pulse oximeters in the presence of motion may be at hand.

  12. Mechanical waves conceptual survey: Its modification and conversion to a standard multiple-choice test

    OpenAIRE

    Pablo Barniol; Genaro Zavala

    2016-01-01

    In this article we present several modifications of the mechanical waves conceptual survey, the most important test to date that has been designed to evaluate university students’ understanding of four main topics in mechanical waves: propagation, superposition, reflection, and standing waves. The most significant changes are (i) modification of several test questions that had some problems in their original design, (ii) standardization of the number of options for each question to five, (iii...

  13. Cytotoxicity Test of One-Step Self-Etching Bonding Agents by Standardized Dentin Barrier Test Using Polyurethane Discs

    Directory of Open Access Journals (Sweden)

    Mi-Joo Kim

    2013-12-01

    Full Text Available This study was performed to standardize a dentin barrier test with the substitute and evaluate the cytotoxicity of one-step self-etching bonding agents. Each of the natural bovine dentin and polyurethane discs were 500-μm thick and were tested using a perfusion device. Following the treatment with 0.05% phenol on the natural bovine disc or three kinds of polyurethane discs—30, 40, and 50 pcf (pounds per cubic foot—cell viability of L-929 was measured by the 3-(4,5-dimethylthiazol-2-yl-2,5-diphenyltetrazolium bromide (MTT assay and expressed as percentages of non-treated group, respectively. A substitute showing permeability similar to that of bovine dentin was determined based on this result. Cytotoxicity test of bonding agents was performed by the selected substitute, the results of which were expressed as percentages of the control. In addition, SEM images were taken after the tests. The cell viability by 40-pcf polyurethane disc was not statistically different from that by bovine dentin disc (P > 0.05. Futurabond DC resulted in the highest cell viability and Bond force the lowest by the 40-pcf polyurethane disc (P < 0.05. The adhesives on the 40-pcf polyurethane disc changed cellular morphology with different degrees on the SEM images. This standardized test might be useful for assessing the cytotoxicity of dental materials applied to dentin before clinical applications.

  14. Comparison of 2 plating techniques for lateral clavicle fractures, using a new standardized biomechanical testing setup.

    Science.gov (United States)

    Suter, Cyrill; Majewski, Martin; Nowakowski, Andrej M

    2017-09-08

    Conservative treatment of lateral clavicle fractures (Neer type II) often ends with unsatisfactory results for patients. Operative treatment is thus gaining acceptance. A retrospective study found success using a double plate technique for these injuries. For the current study, a standardized testing setup was developed to compare the mechanical properties of single versus double plate technique for lateral clavicle fractures. Six synthetic bones were tested for each technique. Neer type IIB fractures were created using computer-aided design (CAD). Fatigue testing was carried out with a cantilever bending test. Parameters measured were cycles undergone, failure load and stiffness at the point of failure. The standardized testing setup was able to provide reproducible failures. The double plate technique lasted about 16,000 more cycles and withstood an additional 22.4 N on average. The new modified standardized testing setup produced reproducible fixation failures for both clavicle fracture fixation techniques. The double plate technique seems to be mechanically superior to the single plate technique.

  15. Standard test method for measurement of corrosion potentials of Aluminum alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a procedure for measurement of the corrosion potential (see Note 1) of an aluminum alloy in an aqueous solution of sodium chloride with enough hydrogen peroxide added to provide an ample supply of cathodic reactant. Note 1—The corrosion potential is sometimes referred to as the open-circuit solution or rest potential. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. Standard practice for digital imaging and communication in nondestructive evaluation (DICONDE) for ultrasonic test methods

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This practice facilitates the interoperability of ultrasonic imaging equipment by specifying image data transfer and archival storage methods in commonly accepted terms. This document is intended to be used in conjunction with Practice E 2339 on Digital Imaging and Communication in Nondestructive Evaluation (DICONDE). Practice E 2339 defines an industrial adaptation of the NEMA Standards Publication titled Digital Imaging and Communications in Medicine (DICOM, see http://medical.nema.org), an international standard for image data acquisition, review, transfer and archival storage. The goal of Practice E 2339, commonly referred to as DICONDE, is to provide a standard that facilitates the display and analysis of NDE test results on any system conforming to the DICONDE standard. Toward that end, Practice E 2339 provides a data dictionary and set of information modules that are applicable to all NDE modalities. This practice supplements Practice E 2339 by providing information object definitions, information ...

  17. Standard Test Method for Hail Impact Resistance of Aerospace Transparent Enclosures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of the impact resistance of an aerospace transparent enclosure, hereinafter called windshield, during hailstorm conditions using simulated hailstones consisting of ice balls molded under tightly controlled conditions. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements see Section 7.

  18. Standard guide for conducting wear tests using a rotary platform, double-head abraser

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This guide covers and is intended to assist in establishing procedures for conducting wear tests of rigid or flexible materials utilizing the rotary platform, double-head abraser (RPDH). 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.2.1 Exception—English units are used when determining coating thickness. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Standard test method for plutonium by Iron (II)/Chromium (VI) amperometric titration

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of plutonium in unirradiated nuclear-grade plutonium dioxide, uranium-plutonium mixed oxides with uranium (U)/plutonium (Pu) ratios up to 21, plutonium metal, and plutonium nitrate solutions. Optimum quantities of plutonium to measure are 7 to 15 mg. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  20. Standard Test Method for Water Absorption of Core Materials for Structural Sandwich Constructions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 This test method covers the determination of the relative amount of water absorption by various types of structural core materials when immersed or in a high relative humidity environment. This test method is intended to apply to only structural core materials; honeycomb, foam, and balsa wood. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  1. Standard Practice for Making and Using C-Ring Stress-Corrosion Test Specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This practice covers the essential features of the design and machining, and procedures for stressing, exposing, and inspecting C-ring type of stress-corrosion test specimens. An analysis is given of the state and distribution of stress in the C-ring. 1.2 Specific considerations relating to the sampling process and to the selection of appropriate test environments are outside the scope of this practice. 1.3 The values stated in SI units are to be regarded as the standard; The values given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Standard test method for ranking resistance of materials to sliding wear using block-on-ring wear test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers laboratory procedures for determining the resistance of materials to sliding wear. The test utilizes a block-on-ring friction and wear testing machine to rank pairs of materials according to their sliding wear characteristics under various conditions. 1.2 An important attribute of this test is that it is very flexible. Any material that can be fabricated into, or applied to, blocks and rings can be tested. Thus, the potential materials combinations are endless. However, the interlaboratory testing has been limited to metals. In addition, the test can be run with various lubricants, liquids, or gaseous atmospheres, as desired, to simulate service conditions. Rotational speed and load can also be varied to better correspond to service requirements. 1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. Wear test results are reported as the volume loss in cubic millimetres for both the block and ring. Materials...

  3. The effect of instructional methodology on high school students natural sciences standardized tests scores

    Science.gov (United States)

    Powell, P. E.

    Educators have recently come to consider inquiry based instruction as a more effective method of instruction than didactic instruction. Experience based learning theory suggests that student performance is linked to teaching method. However, research is limited on inquiry teaching and its effectiveness on preparing students to perform well on standardized tests. The purpose of the study to investigate whether one of these two teaching methodologies was more effective in increasing student performance on standardized science tests. The quasi experimental quantitative study was comprised of two stages. Stage 1 used a survey to identify teaching methods of a convenience sample of 57 teacher participants and determined level of inquiry used in instruction to place participants into instructional groups (the independent variable). Stage 2 used analysis of covariance (ANCOVA) to compare posttest scores on a standardized exam by teaching method. Additional analyses were conducted to examine the differences in science achievement by ethnicity, gender, and socioeconomic status by teaching methodology. Results demonstrated a statistically significant gain in test scores when taught using inquiry based instruction. Subpopulation analyses indicated all groups showed improved mean standardized test scores except African American students. The findings benefit teachers and students by presenting data supporting a method of content delivery that increases teacher efficacy and produces students with a greater cognition of science content that meets the school's mission and goals.

  4. The Introduction of Standardized External Testing in Ukraine: Challenges and Successes

    Science.gov (United States)

    Kovalchuk, Serhiy; Koroliuk, Svitlana

    2012-01-01

    Standardized external testing (SET) began to be implemented in Ukraine in 2008 as an instrument for combating corruption in higher education and ensuring fair university admission. This article examines the conditions and processes that led to the introduction of SET, overviews its implementation over three years (2008-10), analyzes SET and…

  5. Meritocracy 2.0: High-Stakes, Standardized Testing as a Racial Project of Neoliberal Multiculturalism

    Science.gov (United States)

    Au, Wayne

    2016-01-01

    High-stakes, standardized testing is regularly used within in accountability narratives as a tool for achieving racial equality in schools. Using the frameworks of "racial projects" and "neoliberal multiculturalism," and drawing on historical and empirical research, this article argues that not only does high-stakes,…

  6. On the reliability of Fusarium oxysporum f. sp. niveum research: Do we need standardized testing methods?

    Science.gov (United States)

    Fusarium oxysporum f. sp. nivium (Fon) is a pathogen highly variable in aggressiveness that requires a standardized testing method to more accurately define isolate aggressiveness (races) and to identify resistant watermelon lines. Isolates of Fon vary in aggressiveness from weakly to highly aggres...

  7. The Construction of "Illiterate" and "Literate" Youth: The Effects of High-Stakes Standardized Literacy Testing

    Science.gov (United States)

    Kearns, Laura-Lee

    2016-01-01

    High-stakes standardized literacy testing is not neutral and continues to build upon the legacy of dominant power relations in the state in its ability to sort, select and rank students and ultimately produce and name some youth as illiterate in contrast to an ideal white, male, literate citizen. I trace the effects of high-stakes standardized…

  8. Learning by Experience in a Standardized Testing Culture: Investigation of a Middle School Experiential Learning Program

    Science.gov (United States)

    Scogin, Stephen C.; Kruger, Christopher J.; Jekkals, Regan E.; Steinfeldt, Chelsea

    2017-01-01

    Standardized testing pressure sometimes discourages schools from broadly implementing experiential learning opportunities. However, some K-12 schools are challenging the trend with greater commitment to learning by experience. STREAM (science, technology, reading, engineering, arts, mathematics) school is a project-based program providing students…

  9. Integrating GIS in the Middle School Curriculum: Impacts on Diverse Students' Standardized Test Scores

    Science.gov (United States)

    Goldstein, Donna; Alibrandi, Marsha

    2013-01-01

    This case study conducted with 1,425 middle school students in Palm Beach County, Florida, included a treatment group receiving GIS instruction (256) and a control group without GIS instruction (1,169). Quantitative analyses on standardized test scores indicated that inclusion of GIS in middle school curriculum had a significant effect on student…

  10. 77 FR 26989 - Commercial Driver's License Testing and Commercial Learner's Permit Standards

    Science.gov (United States)

    2012-05-08

    ... right to operate a CMV in a State or who is disqualified to operate a commercial motor vehicle... Federal Motor Carrier Safety Administration 49 CFR Parts 384 and 385 RIN 2126-AB02 Commercial Driver's License Testing and Commercial Learner's Permit Standards AGENCY: Federal Motor Carrier Safety...

  11. The Development and Validation of the Test Of Astronomy STandards (TOAST)

    Science.gov (United States)

    Slater, Stephanie J.

    2014-01-01

    The Test Of Astronomy STandards (TOAST) is a comprehensive assessment instrument designed to measure students' general astronomy content knowledge. Built upon the research embedded within a generation of astronomy assessments designed to measure single concepts, the TOAST is appropriate to measure across an entire astronomy course. The TOAST's…

  12. Interpretive Issues with the Roberts Apperception Test for Children: Limitations of the Standardization Group.

    Science.gov (United States)

    Bell, Nancy L.; Nagle, Richard J.

    1999-01-01

    Investigates the validity of the Roberts Apperception Test for Children (RATC) by examining the appropriateness of the standardization norms with other nonclinical samples. Findings suggest that the children in this study form a separate and distinct group from the well-adjusted children upon which the RATC scales were normed and supports previous…

  13. Effect and process evaluation of implementing standardized tests to monitor patients in spinal cord injury rehabilitation

    NARCIS (Netherlands)

    de Groot, S.; Bevers, G.; Post, M.W.; Woldring, F.A.; Mulder, D.G.; van der Woude, L.H.V.

    2010-01-01

    Purpose. To evaluate the implementation of standardized physical and functional tests to monitor patients with a spinal cord injury (SCI) in eight rehabilitation centers and to analyze the enablers and the barriers of the implementation process. Method. The method involved prospective effect and

  14. Examination of Relationships between Participation in School Music Programs of Differing Quality and Standardized Test Results

    Science.gov (United States)

    Johnson, Christopher M.; Memmott, Jenny E.

    2006-01-01

    The purpose of this investigation was to examine the relationship between participation in contrasting school music programs and standardized test scores. Relationships between elementary (third- or fourth-grade) students' academic achievement at comparable schools, but with contrasting music programs as to instructional quality, were…

  15. Comparability of developmental cognitive assessments between standard and computer testing methods

    NARCIS (Netherlands)

    Mandell, D.J.; Sackett, G.P.

    2009-01-01

    Substantial questions have been raised about the validity of using computer-based testing to assess cognitive development with young children. However, little work has been done to assess the comparability of performance elicited using computerized methods with performance garnered using standard

  16. Precision tests of the standard model, the Higgs, and new physics

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics; Volume 62; Issue 2. Precision tests of the standard model, the Higgs, and new physics. Guido Altarelli. Volume 62 Issue 2 February 2004 pp 149-161. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/pram/062/02/0149-0161. Keywords.

  17. MTU America Inc., Agrees to Conduct Proper Testing to Ensure Engines Meet Air Pollution Standards

    Science.gov (United States)

    WASHINGTON - MTU America Inc. (MTU), a subsidiary of Rolls-Royce Power Systems AG, will implement an auditing program to ensure proper emissions testing and compliance with federal emission standards for its heavy-duty diesel non-road engines as par

  18. Standardization of the Denver Developmental Screening Test on Infants from Yucatan, Mexico.

    Science.gov (United States)

    Solomons, Hope C.

    1982-01-01

    Standardization of the Denver Developmental Screening Test (DDST) on 288 babies raning in age from two to 54 weeks in Yucatan, Mexico, yielded such findings as that subtest scores increased with age, and that the DDST failed to identify a "questionable" 16 or 17 babies with borderline scores on the Bayley Motor Scale. (Author/MC)

  19. The Fight's Not Always Fixed: Using Literary Response to Transcend Standardized Test Scores

    Science.gov (United States)

    Avila, JuliAnna

    2012-01-01

    In 2004, the National Endowment for the Arts (NEA) concluded that "literature reading is fading as a meaningful activity, especially among younger people." How can educators continue to teach students about the power of literary response when the priority is for them to achieve proficiency on standardized tests, whose scores can only be narrowly…

  20. Vertical weight-bearing MRI provides an innovative method for standardizing Spurling test.

    Science.gov (United States)

    Yan, Jun; Wang, Yi; Liu, Xiaofeng; Li, Jian; Jin, Zhigao; Zheng, Zugen

    2010-12-01

    Although Spurling test, a foraminal compression test, is commonly used in clinical practice in patients with a suspected cervical radiculopathy, its protocol is still obscure. In undergoing this test, patients extend, laterally flex and slightly rotate neck to the symptomatic side, and then a pressure is applied on the top of patient's head by examiner. The test is scored as positive if it causes pain or tingling that starts in the shoulder and radiates distally to the elbow. But the range of neck motion and level of load are not clearly defined. Magnetic resonance imaging (MRI) has proved to be an excellent method of assessing the situation of cervical intervertebral foramen. Unfortunately the conventional MRI system is not able to fully achieve this goal because it can only examine patient in supine position while Spurling test needs to be performed in a sitting position. Here we hypothesize that vertical weight-bearing MRI provides an innovative method for researching and standardizing the protocols of Spurling test. The result will provide better knowledge of the mechanism of Spurling test. Standardization of the test will improve its sensitivity and rate of reproducibility. Copyright © 2010 Elsevier Ltd. All rights reserved.

  1. A Brief Look at: Test Scores and the Standard Error of Measurement. E&R Report No. 10.13

    Science.gov (United States)

    Holdzkom, David; Sumner, Brian; McMillen, Brad

    2010-01-01

    In the context of standardized testing, the standard error of measurement (SEM) is a measure of the factors other than the student's actual knowledge of the tested material that may affect the student's test score. Such factors may include distractions in the testing environment, fatigue, hunger, or even luck. This means that a student's observed…

  2. Standard test method for linear-elastic plane-strain fracture toughness KIc of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2013-01-01

    1.1 This test method covers the determination of fracture toughness (KIc) of metallic materials under predominantly linear-elastic, plane-strain conditions using fatigue precracked specimens having a thickness of 1.6 mm (0.063 in.) or greater subjected to slowly, or in special (elective) cases rapidly, increasing crack-displacement force. Details of test apparatus, specimen configuration, and experimental procedure are given in the Annexes. Note 1—Plane-strain fracture toughness tests of thinner materials that are sufficiently brittle (see 7.1) can be made using other types of specimens (1). There is no standard test method for such thin materials. 1.2 This test method is divided into two parts. The first part gives general recommendations and requirements for KIc testing. The second part consists of Annexes that give specific information on displacement gage and loading fixture design, special requirements for individual specimen configurations, and detailed procedures for fatigue precracking. Additional a...

  3. Standard test method for linear-elastic plane-strain fracture toughness KIc of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of fracture toughness (KIc) of metallic materials under predominantly linear-elastic, plane-strain conditions using fatigue precracked specimens having a thickness of 1.6 mm (0.063 in.) or greater subjected to slowly, or in special (elective) cases rapidly, increasing crack-displacement force. Details of test apparatus, specimen configuration, and experimental procedure are given in the Annexes. Note 1—Plane-strain fracture toughness tests of thinner materials that are sufficiently brittle (see 7.1) can be made using other types of specimens (1). There is no standard test method for such thin materials. 1.2 This test method is divided into two parts. The first part gives general recommendations and requirements for KIc testing. The second part consists of Annexes that give specific information on displacement gage and loading fixture design, special requirements for individual specimen configurations, and detailed procedures for fatigue precracking. Additional a...

  4. Improving anticoagulation therapy using point-of-care testing and a standardized protocol.

    Science.gov (United States)

    Franke, Curtis A; Dickerson, Lori M; Carek, Peter J

    2008-01-01

    Many patients in primary care require anticoagulation with warfarin for the prevention of venous and systemic embolism. Achieving the goal international normalized ratio (INR) with warfarin is challenging. The purpose of this quality improvement initiative was to increase the proportion of patients taking warfarin with an INR value within the goal range. We included all patients identified on an anticoagulation log in the family medicine residency practice during 3 time periods: baseline, after point-of-care (POC) testing was initiated (intervention period 1), and after a standardized warfarin-dosing protocol was implemented (intervention period 2). Educational sessions were conducted during each intervention period. Measures included the frequency of INR monitoring and the percentage of office visits in which patients' values were within the goal INR range. Data were analyzed using descriptive statistics, the Student t test, and the chi2 test. At baseline, patients had an average of 2.6 INR tests performed, and 30.8% were within the INR goal range. Using POC testing, the frequency of monitoring increased to 4.3 INR tests per patient (P = .04), but the percentage of patients within the INR goal remained low at 32.1% (P=.88). When physicians implemented the standardized protocol to guide warfarin dosing, the frequency of testing was similar (3.8 tests per patient), but the percentage of patients within the INR goal increased to 45.9% (Ptesting increased the frequency of INR testing, and additional use of a standardized protocol for warfarin dosing increased the percentage of patients within the INR goal range. This model of anticoagulation management could be easily implemented in any family medicine office.

  5. Consensus-based reporting standards for diagnostic test accuracy studies for paratuberculosis in ruminants

    DEFF Research Database (Denmark)

    Gardner, Ian A.; Nielsen, Søren Saxmose; Whittington, Richard

    2011-01-01

    The Standards for Reporting of Diagnostic Accuracy (STARD) statement (www.stard-statement.org) was developed to encourage complete and transparent reporting of key elements of test accuracy studies in human medicine. The statement was motivated by widespread evidence of bias in test accuracy...... studies and the finding that incomplete or absent reporting of items in the STARD checklist was associated with overly optimistic estimates of test performance characteristics. Although STARD principles apply broadly, specific guidelines do not exist to account for unique considerations in livestock...

  6. Toxicity testing of dispersed oil requires adherence to standardized protocols to assess potential real world effects.

    Science.gov (United States)

    Coelho, Gina; Clark, James; Aurand, Don

    2013-06-01

    Recently, several researchers have attempted to address Deepwater Horizon incident environmental fate and effects issues using laboratory testing and extrapolation procedures that are not fully reliable measures for environmental assessments. The 2013 Rico-Martínez et al. publication utilized laboratory testing approaches that severely limit our ability to reliably extrapolate such results to meaningful real-world assessments. The authors did not adopt key methodological elements of oil and dispersed oil toxicity standards. Further, they drew real-world conclusions from static exposure tests without reporting actual exposure concentrations. Without this information, it is not possible to compare their results to other research or real spill events that measured and reported exposure concentrations. The 1990s' Chemical Response to Oil Spills: Ecological Effects Research Forum program was established to standardize and conduct exposure characterization in oil and dispersed oil aquatic toxicity testing (Aurand and Coelho, 2005). This commentary raises awareness regarding the necessity of standardized test protocols. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Standard test method for radiochemical determination of plutonium in Soil by alpha spectroscopy

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of plutonium in soils at levels of detection dependent on count time, sample size, detector, background, and tracer yield. This test method describes one acceptable approach to the determination of plutonium in soil. 1.2 This test method is designed for 10 g of soil, previously collected and treated as described in Practices C998 and C999, but sample sizes up to 50 g may be analyzed by this test method. This test method may not be able to completely dissolve all forms of plutonium in the soil matrix. 1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 9.

  8. The relationship between clinical and standardized tests for hand-arm vibration syndrome.

    Science.gov (United States)

    Poole, C J M; Mason, H; Harding, A-H

    2016-06-01

    Standardized laboratory tests are undertaken to assist the diagnosis and staging of hand-arm vibration syndrome (HAVS), but the strength of the relationship between the tests and clinical stages of HAVS is unknown. To assess the relationship between the results of thermal aesthesiometry (TA), vibrotactile (VT) thresholds and cold provocation (CP) tests with the modified Stockholm scales for HAVS and to determine whether the relationship is affected by finger skin temperature. Consecutive records of workers referred to a Tier 5 HAVS assessment centre from 2006 to 2015 were identified. The diagnosis and staging of cases was undertaken from the clinical information contained in the records. Cases with alternative or mixed diagnoses were excluded and staging performed according to the modified Stockholm scale without knowledge of the results of the standardized laboratory tests. A total of 279 cases of HAVS were analysed. Although there was a significant trend for sensorineural (SN) and vascular scores to increase with clinical stage (P 30°C. CP scores distributed bimodally and correlated poorly with clinical staging (r = 0.2). Standardized SN tests distinguish between the lower Stockholm stages, but not above 2SN early. This has implications for health surveillance and UK policy. © Crown copyright 2016.

  9. Good Laboratory Standards for Clinical Next-Generation Sequencing Cancer Panel Tests.

    Science.gov (United States)

    Kim, Jihun; Park, Woong-Yang; Kim, Nayoung K D; Jang, Se Jin; Chun, Sung-Min; Sung, Chang-Ohk; Choi, Jene; Ko, Young-Hyeh; Choi, Yoon-La; Shim, Hyo Sup; Won, Jae-Kyung

    2017-05-01

    Next-generation sequencing (NGS) has recently emerged as an essential component of personalized cancer medicine due to its high throughput and low per-base cost. However, no sufficient guidelines for implementing NGS as a clinical molecular pathology test are established in Korea. To ensure clinical grade quality without inhibiting adoption of NGS, a taskforce team assembled by the Korean Society of Pathologists developed laboratory guidelines for NGS cancer panel testing procedures and requirements for clinical implementation of NGS. This consensus standard proposal consists of two parts: laboratory guidelines and requirements for clinical NGS laboratories. The laboratory guidelines part addressed several important issues across multistep NGS cancer panel tests including choice of gene panel and platform, sample handling, nucleic acid management, sample identity tracking, library preparation, sequencing, analysis and reporting. Requirements for clinical NGS tests were summarized in terms of documentation, validation, quality management, and other required written policies. Together with appropriate pathologist training and international laboratory standards, these laboratory standards would help molecular pathology laboratories to successfully implement NGS cancer panel tests in clinic. In this way, the oncology community would be able to help patients to benefit more from personalized cancer medicine.

  10. Good Laboratory Standards for Clinical Next-Generation Sequencing Cancer Panel Tests

    Directory of Open Access Journals (Sweden)

    Jihun Kim

    2017-05-01

    Full Text Available Next-generation sequencing (NGS has recently emerged as an essential component of personalized cancer medicine due to its high throughput and low per-base cost. However, no sufficient guidelines for implementing NGS as a clinical molecular pathology test are established in Korea. To ensure clinical grade quality without inhibiting adoption of NGS, a taskforce team assembled by the Korean Society of Pathologists developed laboratory guidelines for NGS cancer panel testing procedures and requirements for clinical implementation of NGS. This consensus standard proposal consists of two parts: laboratory guidelines and requirements for clinical NGS laboratories. The laboratory guidelines part addressed several important issues across multistep NGS cancer panel tests including choice of gene panel and platform, sample handling, nucleic acid management, sample identity tracking, library preparation, sequencing, analysis and reporting. Requirements for clinical NGS tests were summarized in terms of documentation, validation, quality management, and other required written policies. Together with appropriate pathologist training and international laboratory standards, these laboratory standards would help molecular pathology laboratories to successfully implement NGS cancer panel tests in clinic. In this way, the oncology community would be able to help patients to benefit more from personalized cancer medicine.

  11. Standard Test Method for Stress-Corrosion of Titanium Alloys by Aircraft Engine Cleaning Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method establishes a test procedure for determining the propensity of aircraft turbine engine cleaning and maintenance materials for causing stress corrosion cracking of titanium alloy parts. 1.2 The evaluation is conducted on representative titanium alloys by determining the effect of contact with cleaning and maintenance materials on tendency of prestressed titanium alloys to crack when subsequently heated to elevated temperatures. 1.3 Test conditions are based upon manufacturer's maximum recommended operating solution concentration. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see and .

  12. Standard test method for initial screening of corrosion inhibiting admixtures for steel in concrete

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method covers a procedure for determining the effects of chemical admixtures on the corrosion of metals in concrete. This test method can be used to evaluate materials intended to inhibit chloride-induced corrosion of steel in concrete. It can also be used to evaluate the corrosivity of admixtures by themselves or in a chloride environment. This test is not applicable for emulsions. 1.2 &solely-SI-units; 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  13. Standard practice for preparation and use of direct tension stress-corrosion test specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This practice covers procedures for designing, preparing, and using ASTM standard tension test specimens for investigating susceptibility to stress-corrosion cracking. Axially loaded specimens may be stressed quantitatively with equipment for application of either a constant load, constant strain, or with a continuously increasing strain. 1.2 Tension test specimens are adaptable for testing a wide variety of product forms as well as parts joined by welding, riveting, or various other methods. 1.3 The exposure of specimens in a corrosive environment is treated only briefly because other standards are being prepared to deal with this aspect. Meanwhile, the investigator is referred to Practices G35, G36, G37, and G44, and to ASTM Special Technical Publication 425 (1).

  14. Standard practice for conducting wire-on-bolt test for atmospheric galvanic corrosion

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This practice covers the evaluation of atmospheric galvanic corrosion of any anodic material that can be made into a wire when in contact with a cathodic material that can be made into a threaded rod. 1.2 When certain materials are used for the anode and cathode, this practice has been used to rate the corrosivity of atmospheres. 1.3 The wire-on-bolt test was first described in 1955 (1), and has since been used extensively with standard materials to determine corrosivity of atmospheres under the names CLIMAT Test (CLassify Industrial and Marine ATmospheres) (2-5) and ATCORR (ATmospheric CORRosivity) (6-9). 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations p...

  15. Mechanical testing of different hip protectors according to a European Standard.

    Science.gov (United States)

    Holzer, Lukas A; von Skrbensky, Gobert; Holzer, Gerold

    2009-11-01

    The effect of hip protectors depends on two factors: (1) mechanical features and (2) wearing time, which depends on the user's compliance. Various biomechanical studies have been performed to test hip protectors' ability in reducing impacts. However, none of these has shown the ability to simulate a fall in a natural way. Therefore, we tested conventional and newly designed hip protectors that might raise user's compliance using a standardised mechanical test. Mechanical testing was performed according to a European Standard testing method for protective impact clothing (EN 1621-1) where an impact is released vertically onto the hip protectors with an energy of 50J. Seven different hip protectors were tested three times each. Using this test, four of the hip protectors were able to reduce the impact below a suggested fracture threshold. The two newly designed hip protectors using special absorption materials were superior (9.10kN, 12.65kN) to the other commercially available hip protectors (21.97-50.62kN), which differ in their mechanical testing performance. This is the first study using a standardised mechanical test on hip protectors and allows an objective comparison because only mechanical properties are tested. New hip protectors with improved mechanical properties are superior to conventional hip protectors. Furthermore, they allow a more appealing design that increases the comfort of the wearer. Mechanical testing should be performed as a first step and has to be followed up by clinical trials to determine and clarify their overall effect.

  16. Synthesizing Information From Language Samples and Standardized Tests in School-Age Bilingual Assessment

    Science.gov (United States)

    Pham, Giang

    2017-01-01

    Purpose Although language samples and standardized tests are regularly used in assessment, few studies provide clinical guidance on how to synthesize information from these testing tools. This study extends previous work on the relations between tests and language samples to a new population—school-age bilingual speakers with primary language impairment—and considers the clinical implications for bilingual assessment. Method Fifty-one bilingual children with primary language impairment completed narrative language samples and standardized language tests in English and Spanish. Children were separated into younger (ages 5;6 [years;months]–8;11) and older (ages 9;0–11;2) groups. Analysis included correlations with age and partial correlations between language sample measures and test scores in each language. Results Within the younger group, positive correlations with large effect sizes indicated convergence between test scores and microstructural language sample measures in both Spanish and English. There were minimal correlations in the older group for either language. Age related to English but not Spanish measures. Conclusions Tests and language samples complement each other in assessment. Wordless picture-book narratives may be more appropriate for ages 5–8 than for older children. We discuss clinical implications, including a case example of a bilingual child with primary language impairment, to illustrate how to synthesize information from these tools in assessment. PMID:28055056

  17. Synthesizing Information From Language Samples and Standardized Tests in School-Age Bilingual Assessment.

    Science.gov (United States)

    Ebert, Kerry Danahy; Pham, Giang

    2017-01-01

    Although language samples and standardized tests are regularly used in assessment, few studies provide clinical guidance on how to synthesize information from these testing tools. This study extends previous work on the relations between tests and language samples to a new population-school-age bilingual speakers with primary language impairment-and considers the clinical implications for bilingual assessment. Fifty-one bilingual children with primary language impairment completed narrative language samples and standardized language tests in English and Spanish. Children were separated into younger (ages 5;6 [years;months]-8;11) and older (ages 9;0-11;2) groups. Analysis included correlations with age and partial correlations between language sample measures and test scores in each language. Within the younger group, positive correlations with large effect sizes indicated convergence between test scores and microstructural language sample measures in both Spanish and English. There were minimal correlations in the older group for either language. Age related to English but not Spanish measures. Tests and language samples complement each other in assessment. Wordless picture-book narratives may be more appropriate for ages 5-8 than for older children. We discuss clinical implications, including a case example of a bilingual child with primary language impairment, to illustrate how to synthesize information from these tools in assessment.

  18. Standardization of reporting procedures for nematicide efficacy testing: a research and extension perspective.

    Science.gov (United States)

    Mueller, J D; Noling, J W

    1996-12-01

    Nematicide tests reported in the Annals of Applied Nematology from 1991 to 1995 were reviewed and evaluated for 24 criteria. Most criteria such as soil type, nematode density, cultivar planted, test location, and nematicide applied were reported in more than adequate detail. Soil moisture content and temperature conditions during the test, field history of pesticide use, agronomic-horticultural production practices, and measurements of yield were reported less adequately. Many reports dealing with fumigant nematicides and application by irrigation had inadequate descriptions of rates and application methodology, Although areas for improvement exist, overall the published works in Annals of Applied Nematology are well-reported experiments. Pressure exists from several elements of hematology to "standarize" reporting procedures and test practices. Due to the diversity of crops, nematodes, nematicides, edaphic and environmental conditions that affect nematicide fate, nematode activity, plant growth, and subsequently nematicide efficacy, creation of a completely standardized format is improbable. More accurate reporting of some test criteria rather than standardization will allow better comparison between tests when results do not concur and allow future researchers to duplicate application rates and methodologies to determine the sources of discrepancies between tests, including environmental variations.

  19. Standard test method for Young's modulus, tangent modulus, and chord modulus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method covers the determination of Young's modulus, tangent modulus, and chord modulus of structural materials. This test method is limited to materials in which and to temperatures and stresses at which creep is negligible compared to the strain produced immediately upon loading and to elastic behavior. 1.2 Because of experimental problems associated with the establishment of the origin of the stress-strain curve described in 8.1, the determination of the initial tangent modulus (that is, the slope of the stress-strain curve at the origin) and the secant modulus are outside the scope of this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory require...

  20. An Ultra-light PRNG Passing Strict Randomness Tests and Suitable for Low Cost Tags

    Directory of Open Access Journals (Sweden)

    OZCANHAN, M. H.

    2016-08-01

    Full Text Available A pseudo-random number generator for low-cost RFID tags is presented. The scheme is simple, sequential and secure, yet has a high performance. Despite its lowest hardware complexity, our proposal represents a better alternative than previous proposals for low-cost tags. The scheme is based on the well-founded pseudo random number generator, Mersenne Twister. The proposed generator takes low-entropy seeds extracted from a physical characteristic of the tag and produces outputs that pass popular randomness tests. Contrarily, previous proposal tests are based on random number inputs from a popular online source, which are simply unavailable to tags. The high performance and satisfactory randomness of present work are supported by extensive test results and compared with similar previous works. Comparison using proven estimation formulae indicates that our proposal has the best hardware complexity, power consumption, and the least cost.

  1. A studentized permutation test for three-arm trials in the 'gold standard' design.

    Science.gov (United States)

    Mütze, Tobias; Konietschke, Frank; Munk, Axel; Friede, Tim

    2017-03-15

    The 'gold standard' design for three-arm trials refers to trials with an active control and a placebo control in addition to the experimental treatment group. This trial design is recommended when being ethically justifiable and it allows the simultaneous comparison of experimental treatment, active control, and placebo. Parametric testing methods have been studied plentifully over the past years. However, these methods often tend to be liberal or conservative when distributional assumptions are not met particularly with small sample sizes. In this article, we introduce a studentized permutation test for testing non-inferiority and superiority of the experimental treatment compared with the active control in three-arm trials in the 'gold standard' design. The performance of the studentized permutation test for finite sample sizes is assessed in a Monte Carlo simulation study under various parameter constellations. Emphasis is put on whether the studentized permutation test meets the target significance level. For comparison purposes, commonly used Wald-type tests, which do not make any distributional assumptions, are included in the simulation study. The simulation study shows that the presented studentized permutation test for assessing non-inferiority in three-arm trials in the 'gold standard' design outperforms its competitors, for instance the test based on a quasi-Poisson model, for count data. The methods discussed in this paper are implemented in the R package ThreeArmedTrials which is available on the comprehensive R archive network (CRAN). Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  2. Unpacking insanity defence standards: An experimental study of rationality and control tests in criminal law

    Directory of Open Access Journals (Sweden)

    Rebecca K. Helm

    2016-07-01

    Full Text Available The present study investigated the impact of different legal standards on mock juror decisions concerning whether a defendant was guilty or not guilty by reason of insanity. Undergraduate students (N = 477 read a simulated case summary involving a murder case and were asked to make an insanity determination. The cases differed in terms of the condition of the defendant (rationality deficit or control deficit and the legal standard given to the jurors to make the determination (Model Penal Code, McNaughten or McNaughten plus a separate control determination. The effects of these variables on the insanity determination were investigated. Jurors also completed questionnaires measuring individualism and hierarchy attitudes and perceptions of facts in the case. Results indicate that under current insanity standards jurors do not distinguish between defendants with rationality deficits and defendants with control deficits regardless of whether the legal standard requires them to do so. Even defendants who lacked control were found guilty at equal rates under a legal standard excusing rationality deficits only and a legal standard excluding control and rationality deficits. This was improved by adding a control test as a partial defence, to be determined after a rationality determination. Implications for the insanity defence in the Criminal Justice System are discussed.

  3. Investigation of the IEC Safety Standard for Small Wind Turbine Design Through Modeling and Testing: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Jonkman, J.; van Dam, J.; Forsyth, T.; Davis, D.

    2003-01-01

    Since 1999, the International Electrotechnical Commission (IEC) Maintenance Team 2 (MT2) has been working on a revision of the IEC 61400-2 standard on the safety, quality, integrity, and design requirements of small wind turbines (SWTs). During this effort, a study was conducted to evaluate the quality of the structural design criteria specified by the original 2 standard. Test measurements and aeroelastic predictions of loads were gathered for a collection of SWTs and evaluated against the simplified load models and load cases specified in the standard. The collection of turbines included variations in rotor size, blade number, rotor location (upwind/downwind), hub type (rigid/teetered), yaw mechanism (free/active), and others. In general, the comparison of load measurements and model predictions exemplified the inaccuracy of the design load levels in the original -2 standard and suggested methods of improvement. Revisions being made to the standard include enhanced load models, new load cases, and improved safety factors. This work should culminate in a revised IEC 61400-2 standard that has a higher degree of applicability and dependability than the original.

  4. Achieving Innovation and Affordability Through Standardization of Materials Development and Testing

    Science.gov (United States)

    Bray, M. H.; Zook, L. M.; Raley, R. E.; Chapman, C.

    2011-01-01

    The successful expansion of development, innovation, and production within the aeronautics industry during the 20th century was facilitated by collaboration of government agencies with the commercial aviation companies. One of the initial products conceived from the collaboration was the ANC-5 Bulletin, first published in 1937. The ANC-5 Bulletin had intended to standardize the requirements of various government agencies in the design of aircraft structure. The national space policy shift in priority for NASA with an emphasis on transferring the travel to low earth orbit to commercial space providers highlights an opportunity and a need for the national and global space industries. The same collaboration and standardization that is documented and maintained by the industry within MIL-HDBK-5 (MMPDS-01) and MIL-HBDK-17 (nonmetallic mechanical properties) can also be exploited to standardize the thermal performance properties, processing methods, test methods, and analytical methods for use in aircraft and spacecraft design and associated propulsion systems. In addition to the definition of thermal performance description and standardization, the standardization for test methods and analysis for extreme environments (high temperature, cryogenics, deep space radiation, etc) would also be highly valuable to the industry. Its subsequent revisions and conversion to MIL-HDBK-5 and then MMPDS-01 established and then expanded to contain standardized mechanical property design values and other related design information for metallic materials used in aircraft, missiles, and space vehicles. It also includes guidance on standardization of composition, processing, and analytical methods for presentation and inclusion into the handbook. This standardization enabled an expansion of the technologies to provide efficiency and reliability to the consumers. It can be established that many individual programs within the government agencies have been overcome with development costs

  5. Bayesian analysis of longitudinal Johne's disease diagnostic data without a gold standard test

    DEFF Research Database (Denmark)

    Wang, C.; Turnbull, B.W.; Nielsen, Søren Saxmose

    2011-01-01

    . An application is presented to an analysis of ELISA and fecal culture test outcomes in the diagnostic testing of paratuberculosis (Johne's disease) for a Danish longitudinal study from January 2000 to March 2003. The posterior probability criterion based on the Bayesian model with 4 repeated observations has......A Bayesian methodology was developed based on a latent change-point model to evaluate the performance of milk ELISA and fecal culture tests for longitudinal Johne's disease diagnostic data. The situation of no perfect reference test was considered; that is, no “gold standard.” A change...... an area under the receiver operating characteristic curve (AUC) of 0.984, and is superior to the raw ELISA (AUC = 0.911) and fecal culture (sensitivity = 0.358, specificity = 0.980) tests for Johne's disease diagnosis....

  6. Standardization of a broth microdilution susceptibility testing method to determine minimum inhibitory concentrations of aquatic bacteria

    DEFF Research Database (Denmark)

    Miller, R.A.; Walker, R.D.; Carson, J.

    2005-01-01

    are below 35 degrees C. Methods and QC ranges defined in this study will enable aquatic animal disease researchers to reliably compare quantitative susceptibility testing data between laboratories, and will be used to ensure both precision and inter-laboratory harmonization...... antimicrobial susceptibility testing methods for bacterial isolates from aquatic animal species. QC ranges were established for Escherichia coli ATCC 25922 and Aeromonas salmonicida subsp. salmonicida ATCC 33658 when testing at 22, 28 and 35 degrees C (E. coli only) for 10 different antimicrobial agents......-Hinton broth. These QC ranges were accepted by the CLSI/NCCLS Subcommittee on Veterinary Antimicrobial Susceptibility Testing in January 2004. This broth microdilution testing method represents the first standardized method for determining MICs of bacterial isolates whose preferred growth temperatures...

  7. Standardized Tests as Outcome Measures for Evaluating Instructional Interventions in Mathematics and Science

    Science.gov (United States)

    Sussman, Joshua Michael

    This three-paper dissertation explores problems with the use of standardized tests as outcome measures for the evaluation of instructional interventions in mathematics and science. Investigators commonly use students' scores on standardized tests to evaluate the impact of instructional programs designed to improve student achievement. However, evidence suggests that the standardized tests may not measure, or may not measure well, the student learning caused by the interventions. This problem is special case of a basic problem in applied measurement related to understanding whether a particular test provides accurate and useful information about the impact of an educational intervention. The three papers explore different aspects of the issue and highlight the potential benefits of (a) using particular research methods and of (b) implementing changes to educational policy that would strengthen efforts to reform instructional intervention in mathematics and science. The first paper investigates measurement problems related to the use of standardized tests in applied educational research. Analysis of the research projects funded by the Institute of Education Sciences (IES) Mathematics and Science Education Program permitted me to address three main research questions. One, how often are standardized tests used to evaluate new educational interventions? Two, do the tests appear to measure the same thing that the intervention teaches? Three, do investigators establish validity evidence for the specific uses of the test? The research documents potential problems and actual problems related to the use of standardized tests in leading applied research, and suggests changes to policy that would address measurement issues and improve the rigor of applied educational research. The second paper explores the practical consequences of misalignment between an outcome measure and an educational intervention in the context of summative evaluation. Simulated evaluation data and a

  8. Electric Vehicle Communications Standards Testing and Validation - Phase II: SAE J2931/1

    Energy Technology Data Exchange (ETDEWEB)

    Pratt, Richard M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Gowri, Krishnan [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-01-15

    Vehicle to grid communication standards enable interoperability among vehicles, charging stations and utility providers and provide the capability to implement charge management. Several standards initiatives by the Society of Automobile Engineers (SAE), International Standards Organization and International Electrotechnical Commission (ISO/IEC), and ZigBee/HomePlug Alliance are developing requirements for communication messages and protocols. Recent work by the Electric Power Research Institute (EPRI) in collaboration with SAE and automobile manufacturers has identified vehicle to grid communication performance requirements and developed a test plan as part of SAE J2931/1 committee work. This laboratory test plan was approved by the SAE J2931/1 committee and included test configurations, test methods, and performance requirements to verify reliability, robustness, repeatability, maximum communication distance, and authentication features of power line carrier (PLC) communication modules at the internet protocol layer level. The goal of the testing effort was to select a communication technology that would enable automobile manufacturers to begin the development and implementation process. The EPRI/Argonne National Laboratory (ANL)/Pacific Northwest National Laboratory (PNNL) testing teams divided the testing so that results for each test could be presented by two teams, performing the tests independently. The PNNL team performed narrowband PLC testing including the Texas Instruments (TI) Concerto, Ariane Controls AC-CPM1, and the MAXIM Tahoe 2 evaluation boards. The scope of testing was limited to measuring the vendor systems communication performance between Electric Vehicle Support Equipment (EVSE) and plug-in electric vehicles (PEV). The testing scope did not address PEV’s CAN bus to PLC or PLC to EVSE (Wi-Fi, cellular, PLC Mains, etc.) communication integration. In particular, no evaluation was performed to delineate the effort needed to translate the IPv6

  9. Evaporation as an ageing procedure prior to wood preservative biological testing: when standardization needs metrology

    Directory of Open Access Journals (Sweden)

    Martin L.

    2014-01-01

    Full Text Available The wood preservation laboratory of Cirad is accredited by COFRAC (French accreditation committee – accreditation No. 1-1686 for tests on (1 durability of wood and wood-based products; (2 protective efficacy of wood preservatives; (3 efficacy of termite control products. In order to test the efficacy of wood preservatives, non-durable wood blocks are treated using different product doses and exposed to the attack of xylophageous organisms (fungi, insects. To reproduce the ageing of treated wood blocks, some laboratory procedures are available. Amongst them, there is an evaporation procedure, reproducing the action of a warm air flow onto treated wood. This ageing step is very discriminant, as only the formulations fixing effectively the active ingredients will pass the biological test afterwards. This ageing by evaporation is described in the EN73 standard. Nevertheless, many points remain difficult to overcome. The tunnels used for the evaporation are all prototypes; as such equipment is not available currently on the market. So each laboratory has got its own tunnel device. Moreover the way to measure the temperature and speed of the air flow is very difficult to achieve considering the prescriptions of the EN73 standard. The EN73 standard is being revised by the European standardization group (CEN TC38 and despite the metrological aspects were crucial and inadequate in former version, they were not considered as they should. The wood preservation laboratory has forwarded remarks in order to supersede some points of the revision document in order to consider the metrological aspects. This is of main importance as the ageing procedure is commonly used prior to most of the biological test, and such tested products are put on the market based on the efficacy results.

  10. CHAOS-BASED ADVANCED ENCRYPTION STANDARD

    KAUST Repository

    Abdulwahed, Naif B.

    2013-05-01

    This thesis introduces a new chaos-based Advanced Encryption Standard (AES). The AES is a well-known encryption algorithm that was standardized by U.S National Institute of Standard and Technology (NIST) in 2001. The thesis investigates and explores the behavior of the AES algorithm by replacing two of its original modules, namely the S-Box and the Key Schedule, with two other chaos- based modules. Three chaos systems are considered in designing the new modules which are Lorenz system with multiplication nonlinearity, Chen system with sign modules nonlinearity, and 1D multiscroll system with stair case nonlinearity. The three systems are evaluated on their sensitivity to initial conditions and as Pseudo Random Number Generators (PRNG) after applying a post-processing technique to their output then performing NIST SP. 800-22 statistical tests. The thesis presents a hardware implementation of dynamic S-Boxes for AES that are populated using the three chaos systems. Moreover, a full MATLAB package to analyze the chaos generated S-Boxes based on graphical analysis, Walsh-Hadamard spectrum analysis, and image encryption analysis is developed. Although these S-Boxes are dynamic, meaning they are regenerated whenever the encryption key is changed, the analysis results show that such S-Boxes exhibit good properties like the Strict Avalanche Criterion (SAC) and the nonlinearity and in the application of image encryption. Furthermore, the thesis presents a new Lorenz-chaos-based key expansion for the AES. Many researchers have pointed out that there are some defects in the original key expansion of AES and thus have motivated such chaos-based key expansion proposal. The new proposed key schedule is analyzed and assessed in terms of confusion and diffusion by performing the frequency and SAC test respectively. The obtained results show that the new proposed design is more secure than the original AES key schedule and other proposed designs in the literature. The proposed

  11. Standard Test Methods for Properties of Continuous Filament Carbon and Graphite Fiber Tows

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 These test methods cover the preparation and tensile testing of resin-impregnated and consolidated test specimens made from continuous filament carbon and graphite yarns, rovings, and tows to determine their tensile properties. 1.2 These test methods also cover the determination of the density and mass per unit length of the yarn, roving, or tow to provide supplementary data for tensile property calculation. 1.3 These test methods include a procedure for sizing removal to provide the preferred desized fiber samples for density measurement. This procedure may also be used to determine the weight percent sizing. 1.4 These test methods include a procedure for determining the weight percent moisture adsorption of carbon or graphite fiber. 1.5 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of t...

  12. Standard test method for damage to contacting solid surfaces under fretting conditions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the studying or ranking the susceptibility of candidate materials to fretting corrosion or fretting wear for the purposes of material selection for applications where fretting corrosion or fretting wear can limit serviceability. 1.2 This test method uses a tribological bench test apparatus with a mechanism or device that will produce the necessary relative motion between a contacting hemispherical rider and a flat counterface. The rider is pressed against the flat counterface with a loading mass. The test method is intended for use in room temperature air, but future editions could include fretting in the presence of lubricants or other environments. 1.3 The purpose of this test method is to rub two solid surfaces together under controlled fretting conditions and to quantify the damage to both surfaces in units of volume loss for the test method. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5...

  13. Determination of soil properties from standard penetration test complemented by torque measurement (SPT-T

    Directory of Open Access Journals (Sweden)

    Anna S. P. Peixoto

    2014-09-01

    Full Text Available The major problem on geotechnical work is to ensure that no settlements occur during the life cycle of the construction. This involves proper design of foundations and their bearing capacity. The Brazilian standard for design and execution of foundations, ABNT (2010 NBR 6122 imposes the utilization of field tests when designing building foundations. The Standard Penetration Test, SPT, ABNT (2001 NBR 6484, is still the most common in-situ test for those purposes. Ranzini (1988 suggested supplementing the conventional SPT with the measurement of the torque (SPT-T required to turn the split spoon after driving, in order to provide a ‘static’ component to a ‘dynamic’ test. The adhesion between the soil and the sampler, obtained by the torque measurement, could be used to calculate the lateral skin friction of piles. This paper describes the SPT-T procedure including both a supplementary equipment and practical aspects. Also it presents an accurate torque measurement, a prediction method to calculate the bearing capacity of piles used in building foundations using the SPT-T test and a comparison between the estimated bearing capacities of building foundations with instrumented load tests in order to validate the method.

  14. Standard Test Method for Measuring Optical Angular Deviation of Transparent Parts

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This test method covers measuring the angular deviation of a light ray imposed by transparent parts such as aircraft windscreens and canopies. The results are uncontaminated by the effects of lateral displacement, and the procedure may be performed in a relatively short optical path length. This is not intended as a referee standard. It is one convenient method for measuring angular deviations through transparent windows. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. Standardized Tests and Our Children: A Guide to Testing Reform = Los Examenes Estandarizados y Nuestros Ninos: Guia para la Reforma de Examenes Estandarizados.

    Science.gov (United States)

    National Center for Fair and Open Testing (FairTest), Cambridge, MA.

    English and Spanish versions of a guide to testing reform are presented. The guide explains alternatives to standardized testing for educational assessment and shows how these new methods of evaluation will improve education. Standardized tests are used for an increasing number of purposes in the school system, but there is no proof that their use…

  16. ACCESS, Absolute Color Calibration Experiment for Standard Stars: Integration, Test, and Ground Performance

    Science.gov (United States)

    Kaiser, Mary Elizabeth; Morris, Matthew; Aldoroty, Lauren; Kurucz, Robert; McCandliss, Stephan; Rauscher, Bernard; Kimble, Randy; Kruk, Jeffrey; Wright, Edward L.; Feldman, Paul; Riess, Adam; Gardner, Jonathon; Bohlin, Ralph; Deustua, Susana; Dixon, Van; Sahnow, David J.; Perlmutter, Saul

    2018-01-01

    Establishing improved spectrophotometric standards is important for a broad range of missions and is relevant to many astrophysical problems. Systematic errors associated with astrophysical data used to probe fundamental astrophysical questions, such as SNeIa observations used to constrain dark energy theories, now exceed the statistical errors associated with merged databases of these measurements. ACCESS, “Absolute Color Calibration Experiment for Standard Stars”, is a series of rocket-borne sub-orbital missions and ground-based experiments designed to enable improvements in the precision of the astrophysical flux scale through the transfer of absolute laboratory detector standards from the National Institute of Standards and Technology (NIST) to a network of stellar standards with a calibration accuracy of 1% and a spectral resolving power of 500 across the 0.35‑1.7μm bandpass. To achieve this goal ACCESS (1) observes HST/ Calspec stars (2) above the atmosphere to eliminate telluric spectral contaminants (e.g. OH) (3) using a single optical path and (HgCdTe) detector (4) that is calibrated to NIST laboratory standards and (5) monitored on the ground and in-flight using a on-board calibration monitor. The observations are (6) cross-checked and extended through the generation of stellar atmosphere models for the targets. The ACCESS telescope and spectrograph have been designed, fabricated, and integrated. Subsystems have been tested. Performance results for subsystems, operations testing, and the integrated spectrograph will be presented. NASA sounding rocket grant NNX17AC83G supports this work.

  17. BARTTest: Community-Standard Atmospheric Radiative-Transfer and Retrieval Tests

    Science.gov (United States)

    Harrington, Joseph; Himes, Michael D.; Cubillos, Patricio E.; Blecic, Jasmina; Challener, Ryan C.

    2018-01-01

    Atmospheric radiative transfer (RT) codes are used both to predict planetary and brown-dwarf spectra and in retrieval algorithms to infer atmospheric chemistry, clouds, and thermal structure from observations. Observational plans, theoretical models, and scientific results depend on the correctness of these calculations. Yet, the calculations are complex and the codes implementing them are often written without modern software-verification techniques. The community needs a suite of test calculations with analytically, numerically, or at least community-verified results. We therefore present the Bayesian Atmospheric Radiative Transfer Test Suite, or BARTTest. BARTTest has four categories of tests: analytically verified RT tests of simple atmospheres (single line in single layer, line blends, saturation, isothermal, multiple line-list combination, etc.), community-verified RT tests of complex atmospheres, synthetic retrieval tests on simulated data with known answers, and community-verified real-data retrieval tests.BARTTest is open-source software intended for community use and further development. It is available at https://github.com/ExOSPORTS/BARTTest. We propose this test suite as a standard for verifying atmospheric RT and retrieval codes, analogous to the Held-Suarez test for general circulation models. This work was supported by NASA Planetary Atmospheres grant NX12AI69G, NASA Astrophysics Data Analysis Program grant NNX13AF38G, and NASA Exoplanets Research Program grant NNX17AB62G.

  18. Radiated radiofrequency immunity testing of automated external defibrillators - modifications of applicable standards are needed

    Directory of Open Access Journals (Sweden)

    Bassen Howard I

    2011-07-01

    Full Text Available Abstract Background We studied the worst-case radiated radiofrequency (RF susceptibility of automated external defibrillators (AEDs based on the electromagnetic compatibility (EMC requirements of a current standard for cardiac defibrillators, IEC 60601-2-4. Square wave modulation was used to mimic cardiac physiological frequencies of 1 - 3 Hz. Deviations from the IEC standard were a lower frequency limit of 30 MHz to explore frequencies where the patient-connected leads could resonate. Also testing up to 20 V/m was performed. We tested AEDs with ventricular fibrillation (V-Fib and normal sinus rhythm signals on the patient leads to enable testing for false negatives (inappropriate "no shock advised" by the AED. Methods We performed radiated exposures in a 10 meter anechoic chamber using two broadband antennas to generate E fields in the 30 - 2500 MHz frequency range at 1% frequency steps. An AED patient simulator was housed in a shielded box and delivered normal and fibrillation waveforms to the AED's patient leads. We developed a technique to screen ECG waveforms stored in each AED for electromagnetic interference at all frequencies without waiting for the long cycle times between analyses (normally 20 to over 200 s. Results Five of the seven AEDs tested were susceptible to RF interference, primarily at frequencies below 80 MHz. Some induced errors could cause AEDs to malfunction and effectively inhibit operator prompts to deliver a shock to a patient experiencing lethal fibrillation. Failures occurred in some AEDs exposed to E fields between 3 V/m and 20 V/m, in the 38 - 50 MHz range. These occurred when the patient simulator was delivering a V-Fib waveform to the AED. Also, we found it is not possible to test modern battery-only-operated AEDs for EMI using a patient simulator if the IEC 60601-2-4 defibrillator standard's simulated patient load is used. Conclusions AEDs experienced potentially life-threatening false-negative failures from

  19. Standard Test Method for Gravimetric Determination of Nonvolatile Residue from Cleanroom Gloves

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of solvent extractable nonvolatile residue (NVR) from gloves used in cleanrooms where spacecraft are assembled, cleaned, or tested. 1.2 The NVR of interest is that which can be extracted from gloves using a specified solvent that has been selected for its extracting qualities, or because it is representative of solvents used in the particular facility. Alternative solvents may be used, but since their use may result in different values being generated, they must be identified in the procedure data sheet. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  20. Mechanical properties test and microstructure analysis of polyoxymethylene (POM) micro injection moulded standard parts

    DEFF Research Database (Denmark)

    Tosello, Guido; Lucchetta, Giovanni; Hansen, Hans Nørgaard

    2009-01-01

    The tensile mechanical properties and the micro structure of micro injection moulded polyoxymethylene (POM) test parts were investigated in this paper. The effects of different injection moulding processing conditions on ultimate tensile stress and strain at break were analyzed. Additionally......, the effects of miniaturization on the mechanical properties were investigated by executing injection moulding with both a standard tool designed according to ISO 527-2 and a miniaturized test part obtained from the standard design by a downscaling factor 10. The experiments have been performed according...... to factorial plans, in which the factors of interest were mould temperature, melt temperature and dimensional range of the specimen (i.e. macro and micro parts). Micro structure analysis was performed by means of plastography techniques and revealed that high mould and melt temperatures resulted on a thin skin...

  1. Towards standardization of in-site parabolic trough collector testing in solar thermal power plants

    Science.gov (United States)

    Sallaberry, Fabienne; Valenzuela, Loreto; de Jalón, Alberto García; Leon, Javier; Bernad, Ignacio David

    2016-05-01

    This paper presents a summary of the testing procedure and a validation of the methodology of parabolic trough collector in solar thermal power plants. The applied testing methodology is the one proposed within the Spanish standardization sub-committee AEN/CTN 206/SC117 working group WG2 related to the components for solar thermal power plants. This methodology is also proposed within the international committee IEC TC 117 (Standard draft IEC 62862-3-2 Ed. 1.0). This study is done at Plataforma Solar de Almería (PSA) in Almeria within the European project STAGE-STE. This paper presents the results of the optical and thermal efficiency of a large-size parabolic trough collector. The obtained values are similar to the previous analysis on this collector by PSA. The results of the tracking system have a good accuracy compared to the acceptance angle of the concentrator.

  2. Genetic and Antigenic Analysis of Adenovirus Type 3 Strains Showing Intermediate Behavior in Standard Seroneutralization Test

    Directory of Open Access Journals (Sweden)

    Márcia TB Moraes

    1998-03-01

    Full Text Available During an epidemiological survey of acute respiratory infection in Rio de Janeiro, among 208 adenovirus isolates, we found two strains that we were not able, by a standard neutralization procedure, to distinguish between type 3 or 7. However, DNA restriction pattern for the two strains with different enzymes were analyzed and showed a typical Ad3h profile. Using a cross-neutralization test in which both Ad3p and Ad7p antisera were used in different concentration against 100 TCID50 of each adenovirus standard and both isolates, we were able to confirm that the two isolates belong to serotype 3. An hemagglutination inhibition test also corroborated the identification of both strains as adenovirus type 3. Comparing Ad3h and Ad3p genome, we observed 16 different restriction enzyme sites, three of which were located in genomic regions encoding polypeptides involved in neutralization sites

  3. Bridging the Gap of Standardized Animals Models for Blast Neurotrauma: Methodology for Appropriate Experimental Testing.

    Science.gov (United States)

    VandeVord, Pamela J; Leonardi, Alessandra Dal Cengio; Ritzel, David

    2016-01-01

    Recent military combat has heightened awareness to the complexity of blast-related traumatic brain injuries (bTBI). Experiments using animal, cadaver, or biofidelic physical models remain the primary measures to investigate injury biomechanics as well as validate computational simulations, medical diagnostics and therapies, or protection technologies. However, blast injury research has seen a range of irregular and inconsistent experimental methods for simulating blast insults generating results which may be misleading, cannot be cross-correlated between laboratories, or referenced to any standard for exposure. Both the US Army Medical Research and Materiel Command and the National Institutes of Health have noted that there is a lack of standardized preclinical models of TBI. It is recommended that the blast injury research community converge on a consistent set of experimental procedures and reporting of blast test conditions. This chapter describes the blast conditions which can be recreated within a laboratory setting and methodology for testing in vivo models within the appropriate environment.

  4. Standard Test Method for Measuring Optical Distortion in Transparent Parts Using Grid Line Slope

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 When an observer looks through an aerospace transparency, relative optical distortion results, specifically in thick, highly angled, multilayered plastic parts. Distortion occurs in all transparencies but is especially critical to aerospace applications such as combat and commercial aircraft windscreens, canopies, or cabin windows. This is especially true during operations such as takeoff, landing, and aerial refueling. It is critical to be able to quantify optical distortion for procurement activities. 1.2 This test method covers the apparatus and procedures that are suitable for measuring the grid line slope (GLS) of transparent parts, including those that are small or large, thin or thick, flat or curved, or already installed. This test method is not recommended for raw material. 1.3 The values stated in SI units shall be regarded as the standard. The values given in parentheses are for information only. This standard does not purport to address all of the safety concerns, if any, associated with it...

  5. Standard test method for quantitative determination of americium 241 in plutonium by Gamma-Ray spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1994-01-01

    1.1 This test method covers the quantitative determination of americium 241 by gamma-ray spectrometry in plutonium nitrate solution samples that do not contain significant amounts of radioactive fission products or other high specific activity gamma-ray emitters. 1.2 This test method can be used to determine the americium 241 in samples of plutonium metal, oxide and other solid forms, when the solid is appropriately sampled and dissolved. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. Standard test method for determining atmospheric chloride deposition rate by wet candle method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers a wet candle device and its use in measuring atmospheric chloride deposition (amount of chloride salts deposited from the atmosphere on a given area per unit time). 1.2 Data on atmospheric chloride deposition can be useful in classifying the corrosivity of a specific area, such as an atmospheric test site. Caution must be exercised, however, to take into consideration the season because airborne chlorides vary widely between seasons. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. Standard Test Methods for Solar Energy Transmittance and Reflectance (Terrestrial) of Sheet Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1971-01-01

    1.1 These test methods cover the measurement of solar energy transmittance and reflectance (terrestrial) of materials in sheet form. Method A, using a spectrophotometer, is applicable for both transmittance and reflectance and is the referee method. Method B is applicable only for measurement of transmittance using a pyranometer in an enclosure and the sun as the energy source. Specimens for Method A are limited in size by the geometry of the spectrophotometer while Method B requires a specimen 0.61 m2 (2 ft2). For the materials studied by the drafting task group, both test methods give essentially equivalent results. 1.2 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  8. Standard test method for color and color difference of whitewares by abriged spectrophotometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 This test method describes the instrumental measurement of the reflection properties and color of ceramic glazes and other whitewares by the use of a spectrophotometer or spectrocolorimeter with a hemispherical optical measuring system, such as an integrating sphere. 1.2 The test method is suitable for use with most specimens having an exterior flat surface large enough to cover the spectrophotometer sample port. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Vehicle to Grid Communication Standards Development, Testing and Validation - Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Gowri, Krishnan; Pratt, Richard M.; Tuffner, Francis K.; Kintner-Meyer, Michael CW

    2011-09-01

    In the US, more than 10,000 electric vehicles (EV) have been delivered to consumers during the first three quarters of 2011. A large majority of these vehicles are battery electric, often requiring 220 volt charging. Though the vehicle manufacturers and charging station manufacturers have provided consumers options for charging preferences, there are no existing communications between consumers and the utilities to manage the charging demand. There is also wide variation between manufacturers in their approach to support vehicle charging. There are in-vehicle networks, charging station networks, utility networks each using either cellular, Wi-Fi, ZigBee or other proprietary communication technology with no standards currently available for interoperability. The current situation of ad-hoc solutions is a major barrier to the wide adoption of electric vehicles. SAE, the International Standards Organization/International Electrotechnical Commission (ISO/IEC), ANSI, National Institute of Standards and Technology (NIST) and several industrial organizations are working towards the development of interoperability standards. PNNL has participated in the development and testing of these standards in an effort to accelerate the adoption and development of communication modules.

  10. Weathering Tests on Protective Helmets Approved to Australian Standard as 1698 (For Vehicle Users).

    Science.gov (United States)

    1980-07-01

    wiped off and a reasonable gloss restored. The crowns of the helmets were affected most but the whole test area showed some evidence of weatherina...The polycarbonate helmets still had a good closs. * .R.P.: Glass fibre reinforced plastic. [4! ir .. . . . . . . . .. . . - The Standards Association...of te helmets. Neithor the depth of pervetration nor the sizes of the holes were measured. Deformation of the polycarbonate shells was ductile and

  11. Improving Hispanic students' performance on science standardized tests: Successful practices from four elementary campuses

    Science.gov (United States)

    Gonzalez, Yvonne Lynne

    This qualitative, descriptive multiple case study took place in a Southwest Texas city bordering Mexico. The study examined specific resources and practices used in four different exemplary-rated elementary school campuses, with standardized test data reflecting 93% or more of their 5th-grade Hispanic student population passing the state mandated standardized science test. The sample for this study included one principal, one assistant principal, and three 5th-grade teachers from each campus. In total, the sample participants consisted of four principals, four assistant principals, and 12 5th-grade teachers. Data collection involved conducting in-depth, semi-structured interviews guided by five literature-based, researcher-generated questions. Fifth grade teachers and administrators reflected and reported upon their pedagogy for best practices in helping Hispanic students achieve success. Analysis of the data revealed eight themes: (a) successful schools have committed teachers, an environment conducive to learning, and incorporate best practices that work for all students; (b) curriculum alignment is very important; (c) teachers have access to a variety of resources; (d) teacher collaboration and planning is very important; (e) science camps, science reviews, and hands-on centers are effective in preparing students for the standardized test; (f) the most effective instructional practices include high emphasis on vocabulary, hands-on and differentiated instruction, and the 5E Model; (g) teachers see value in self-contained, dual-language classes; and (h) professional development and performance feedback are important to educators. The results of this study provide educational leaders with specific science instructional resources, practices, and interventions proven effective for the 5 th-grade Hispanic student population in passing the science state standardized test.

  12. Proposed annex to the ASTM Standard Guide E1676-95, bioaccumulation testing utilizing Eisenia foetida

    Energy Technology Data Exchange (ETDEWEB)

    Roper, J. [ASCI Corp., Vicksburg, MS (United States); Simmers, J.; Lee, C.; Tatem, H. [USACE Waterways Experiment Station, Vicksburg, MS (United States)

    1995-12-31

    A detailed description of the method developed at the Waterways Experiment Station (WES) to determine sediment toxicity utilizing the earthworm, Eisenia foetida. This method has been used successfully in evaluating the target contaminants; metals, PAHs, and PCBs. This procedure is currently a proposed annex to the ASTM Standard Guide E1676-95: Conducting a Laboratory Soil Toxicity Test With The Lumbricid Earthworm, Eisenia foetida.

  13. Fire Safety Aspects of Polymeric Materials. Volume 2. Test Methods, Specifications and Standards

    Science.gov (United States)

    1979-01-01

    developed to measure a specific hazard. For example, DOC FF 3-71 flammability standard for children’s sleepwear is intended to control the hazard of flame...volumes. This report summarizes the state of the art on test methods which can be employed for evaluating various aspects of flammability behavior in...IRVING N. EINHORN, Flammability Restarch Center, Division of Matecals Science and Engineering, Flammability Research Center, College of Engineering

  14. Primin in the European standard patch test series for 20 years

    DEFF Research Database (Denmark)

    Zachariae, Claus; Engkilde, Kåre; Johansen, Jeanne Duus

    2007-01-01

    Primin was included in the European standard series (ESS) in 1984. In 2000, a primin-free variant of Primula obconica, the main source of contact allergy to primin, was introduced in the market. The aim of this study was to analyse the trends of primin allergy in 13 986 consecutively patch-tested...... allergy to primin was seen (P age groups. The frequency was 0.5% during 2000-2004. Contact allergy has been rare since 2000. The low frequency of positive patch test to primin does not support inclusion in the ESS in our region....

  15. Accuracy of eyewitness identification is significantly associated with performance on a standardized test of face recognition.

    Science.gov (United States)

    Morgan, Charles A; Hazlett, Gary; Baranoski, Madelon; Doran, Anthony; Southwick, Steven; Loftus, Elizabeth

    2007-01-01

    This study assessed the relationship between Eyewitness Accuracy regarding a person met under conditions of high stress and performance on a standardized, neutral test of memory for human faces. Fifty-three U.S. Army personnel were exposed to interrogation stress. Forty-eight hours later, participants were administered the Weschler Face Test and then asked to identify the one interrogator who they had encountered 48 h earlier. A significant positive relationship was observed between performance on the Weschler Face Test and performance on the Eyewitness task. Inaccurate eyewitnesses exhibited more False Negative errors when performing the Weschler Face Test. Trait ability to remember human faces may be related to how accurately people recall faces that are associated with highly emotional circumstances. Detection probability methods, such as ROC curve analyses, may be of assistance to forensic examiners, the police, and the courts, when assessing the probability that eyewitness evidence is accurate.

  16. Correlation of Standard and Cone Penetration Tests: Case Study from Tekirdag (Turkey)

    Science.gov (United States)

    Feda Aral, I.; Gunes, Ekrem

    2017-10-01

    In geotechnical engineering, the Standard Penetration Test (SPT-N value) is often used as an in-situ test. The Cone Penetration Test (CPT) is based on design and cone resistance (qc) and is becoming increasingly widespread. However, there is also a need for a SPT-CPT correlation association that can be used in the basic design. In this study, the values of the SPT-CPT tests applied to the ground were compared and tried to generate a certain statistical data. SPT and CPT experiments were performed side by side to determine the soil properties. Formulas have been developed using various statistical methods and correlation coefficients have been established between the data obtained for “high-medium-low plastic clay” and “sand and sandy clayey soils”. The obtained data were compared with the studies in the literature.

  17. Standard test methods for determining average grain size using semiautomatic and automatic image analysis

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2015-01-01

    1.1 These test methods are used to determine grain size from measurements of grain intercept lengths, intercept counts, intersection counts, grain boundary length, and grain areas. 1.2 These measurements are made with a semiautomatic digitizing tablet or by automatic image analysis using an image of the grain structure produced by a microscope. 1.3 These test methods are applicable to any type of grain structure or grain size distribution as long as the grain boundaries can be clearly delineated by etching and subsequent image processing, if necessary. 1.4 These test methods are applicable to measurement of other grain-like microstructures, such as cell structures. 1.5 This standard deals only with the recommended test methods and nothing in it should be construed as defining or establishing limits of acceptability or fitness for purpose of the materials tested. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user ...

  18. Is It Working? Distractor Analysis Results from the Test Of Astronomy STandards (TOAST) Assessment Instrument

    Science.gov (United States)

    Slater, Stephanie

    2009-05-01

    The Test Of Astronomy STandards (TOAST) assessment instrument is a multiple-choice survey tightly aligned to the consensus learning goals stated by the American Astronomical Society - Chair's Conference on ASTRO 101, the American Association of the Advancement of Science's Project 2061 Benchmarks, and the National Research Council's National Science Education Standards. Researchers from the Cognition in Astronomy, Physics and Earth sciences Research (CAPER) Team at the University of Wyoming's Science and Math Teaching Center (UWYO SMTC) have been conducting a question-by-question distractor analysis procedure to determine the sensitivity and effectiveness of each item. In brief, the frequency each possible answer choice, known as a foil or distractor on a multiple-choice test, is determined and compared to the existing literature on the teaching and learning of astronomy. In addition to having statistical difficulty and discrimination values, a well functioning assessment item will show students selecting distractors in the relative proportions to how we expect them to respond based on known misconceptions and reasoning difficulties. In all cases, our distractor analysis suggests that all items are functioning as expected. These results add weight to the validity of the Test Of Astronomy STandards (TOAST) assessment instrument, which is designed to help instructors and researchers measure the impact of course-length duration instructional strategies for undergraduate science survey courses with learning goals tightly aligned to the consensus goals of the astronomy education community.

  19. Standard Test Method for Effects of Cleaning and Chemical Maintenance Materials on Painted Aircraft Surfaces

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers determination of the effects of cleaning solutions and liquid cleaner concentrates on painted aircraft surfaces (Note 1). Streaking, discoloration, and blistering may be determined visually. Softening is determined with a series of specially prepared pencils wherein determination of the softest pencil to rupture the paint film is made. Note 1—This test method is applicable to any paint film that is exposed to cleaning materials. MIL-PRF-85285 has been selected as a basic example. When other paint finishes are used, refer to the applicable material specification for panel preparation and system curing prior to testing. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user ...

  20. Standard Test Method for Sizing and Counting Particulate Contaminant In and On Clean Room Garments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This test method covers the determination of detachable particulate contaminant 5 m or larger, in and on the fabric of clean room garments. 1.2 This test method does not apply to nonporous fabrics such as Tyvek or Gortex. It only applies to fabrics that are porous such as cotton or polyester. 1.3 The values stated in SI units are to be regarded as the standard. The inch-pound values given in parentheses are for information only. 1.4 This test method provides not only the traditional optical microscopic analysis but also a size distribution and surface obscuration analysis for particles on a fine-textured membrane filter or in a tape lift sample. It utilizes transmitted illumination to render all particles darker than the background for gray level detection. Particles collected on opaque plates must be transferred to a suitable membrane filter. This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associat...

  1. 1.5nm fabrication of test patterns for characterization of metrological systems

    Science.gov (United States)

    Babin, S.; Bouet, N.; Cabrini, S.; Calafiore, G.; Conley, R.; Gevorkyan, G.; Munechika, K.; Vladár, A.; Yashchuk, V. V.

    2017-03-01

    The semiconductor industry is moving toward a half-pitch of 7 nm. The required metrology equipment should be one order of magnitude more accurate than that. Any metrology tool is only as good as it is calibrated. The characterization of metrology systems requires test patterns that are one order of magnitude smaller than the measured features. The test sample was designed in such a way that the distribution of linewidths appears to be random at any location and any magnification. The power spectral density of such pseudo-random test pattern is inherently flat, down to the minimum size of lines. Metrology systems add a cut-off of the spectra at high frequencies; the shape of the cut-off characterizes the system in its entire dynamic range. This method is widely used in optics, and has allowed optical systems to be perfected down to their diffraction limit. There were attempts to use the spectral method to characterize nanometrology systems such as SEMs, but the absence of natural samples with known spatial frequencies was a common problem. Pseudo-random test patterns with linewidths down to 1.5 nm were fabricated. The system characterization includes the imaging of a pseudo-random test sample and image analysis by a developed software to automatically extract the power spectral density and the contrast transfer function of the nanoimaging system.

  2. Development of a standard test procedure for devices on thermal weed control

    Directory of Open Access Journals (Sweden)

    Verschwele, Arnd

    2016-02-01

    Full Text Available In contrast to the standard evaluation of the efficacy of pesticides and the testing of spraying equipment there are no comparable testing procedure for equipment of thermal weed control. It is the aim of the investigations described here to develop a standard procedure for assessing temperature distribution and biological efficacy. This will be the basis for quality testing which can be directly used by practical users. Also it can help engineers to improve devices if constructive gaps will be identified by these tests. The results from testing a flaming device (Green-Flame 850 E demonstrated such a potential for technical improvement: The temperature decreased from 159 °C to 89 °C by increasing driving speed from 0.35 m/s to 0.81 m/s. The variation of the temperature related to the working width was extremely high: The range was 60 °C at highest speed and 79 °C at lowest speed, respectively. The biological efficacy against the test plant species Sinapis arvensis was also affected by the driving speed and the corresponding temperature. A driving speed not higher than 0.53 m/s resulted in efficacy rates of almost 95%. However, the efficacy was only 66% at the highest tested speed of 0.81 m/s. Thus, the needed effective temperature is between 89 °C und 106 °C. In contrast, Lolium perenne was controlled by only 72% under the tested conditions. Here a dose-response relationship was not observed. The variation of the temperature, as well as the biological efficacy, was extremely heterogeneous and not satisfying in terms of an economic and safe use. Similar results were found for other devices on thermal weed control.

  3. The false sero-negativity of brucella standard agglutination test: Prozone phenomenon

    Directory of Open Access Journals (Sweden)

    İrfan Binici

    2011-12-01

    Full Text Available Objectives: We aimed to assess prozone phenomenon that is quite rare and causes false negativity in serological diagnosisof brucellosis with standard dilution titers.Materials and methods: In this study the tests of four cases that have false negative serological results were evaluated.Blood cultures were obtained from all cases while cerebrospinal fluid cultures were studied in the two cases. Standardagglutination test (SAT and Coombs test were performed to all patients.Results: SAT and Coombs test was negative in titers up to 1/640 in all cases. The SAT and Coombs tests in cerebrospinalfluid (CSF of the two cases with neurobrucellosis diagnosis were negative, as well. Since the clinical and laboratoryfindings suggested the brucellosis, the serums were restudied by diluting up to 1/10240 titer and we saw that the first3 cases became positive at a titer of 1/1280. The fourth case remained negative and therefore, we applied high dilutionCoombs test. This time the test gave a positive result at 1/10240 titer beginning from 1/2560 titer. B.melitensis wasisolated from two cases.Conclusion: SAT and Coombs’ test must be diluted to titers 1/2560 or more in order to exclude false sero-negativity incases with clinical and laboratory findings suggesting brucellosis. J Microbiol Infect Dis 2011; 1(3:110-113

  4. Twenty Years On!: Updating the IEA BESTEST Building Thermal Fabric Test Cases for ASHRAE Standard 140: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Judkoff, R.; Neymark, J.

    2013-07-01

    ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs applies the IEA BESTEST building thermal fabric test cases and example simulation results originally published in 1995. These software accuracy test cases and their example simulation results, which comprise the first test suite adapted for the initial 2001 version of Standard 140, are approaching their 20th anniversary. In response to the evolution of the state of the art in building thermal fabric modeling since the test cases and example simulation results were developed, work is commencing to update the normative test specification and the informative example results.

  5. Inter-rater reliability of three standardized functional tests in patients with low back pain

    Directory of Open Access Journals (Sweden)

    Tidstrand Johan

    2009-06-01

    Full Text Available Abstract Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs. Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0, for sitting on a Bobath ball good (κ: 0.79 and very good (κ: 0.88 and for the unilateral pelvic lift: good (κ: 0.61 and moderate (κ: 0.47. Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their

  6. Inter-rater reliability of three standardized functional tests in patients with low back pain

    Science.gov (United States)

    Tidstrand, Johan; Horneij, Eva

    2009-01-01

    Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs). Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ) and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0), for sitting on a Bobath ball good (κ: 0.79) and very good (κ: 0.88) and for the unilateral pelvic lift: good (κ: 0.61) and moderate (κ: 0.47). Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their ability to evaluate lumbar

  7. Formulation of a candidate glass for use as an acceptance test standard material

    Energy Technology Data Exchange (ETDEWEB)

    Ebert, W.L.; Strachan, D.M.; Wolf, S.F.

    1998-04-01

    In this report, the authors discuss the formulation of a glass that will be used in a laboratory testing program designed to measure the precision of test methods identified in the privatization contracts for the immobilization of Hanford low-activity wastes. Tests will be conducted with that glass to measure the reproducibility of tests and analyses that must be performed by glass producers as a part of the product acceptance procedure. Test results will be used to determine if the contractually required tests and analyses are adequate for evaluating the acceptability of likely immobilized low-activity waste (ILAW) products. They will also be used to evaluate if the glass designed for use in these tests can be used as an analytical standard test material for verifying results reported by vendors for tests withg ILAW products. The results of those tests and analyses will be presented in a separate report. The purpose of this report is to document the strategy used to formulate the glass to be used in the testing program. The low-activity waste reference glass LRM that will be used in the testing program was formulated to be compositionally similar to ILAW products to be made with wastes from Hanford. Since the ILAW product compositions have not been disclosed by the vendors participating in the Hanford privatization project, the composition of LRM was formulated based on simulated Hanford waste stream and amounts of added glass forming chemicals typical for vitrified waste forms. The major components are 54 mass % SiO{sub 2}, 20 mass % Na{sub 2}O, 10 mass % Al{sub 2}O{sub 3}, 8 mass % B{sub 2}O{sub 3}, and 1.5 mass % K{sub 2}O. Small amounts of other chemicals not present in Hanford wastes were also included in the glass, since they may be included as chemical additives in ILAW products. This was done so that the use of LRM as a composition standard could be evaluated. Radionuclides were not included in LRM because a nonradioactive material was desired.

  8. BARTTest: Community-Standard Radiative-Transfer Tests II: Retrieval Models

    Science.gov (United States)

    Harrington, Joseph; Himes, Michael D.; Cubillos, Patricio; Blecic, Jasmina; Challener, Ryan C.

    2017-10-01

    Atmospheric radiative transfer codes are used both to predict planetary spectra and in retrieval algorithms to interpret data. Observational plans, theoretical models, and scientific results thus depend on the correctness of these calculations. Yet, the calculations are complex and the codes implementing them are often written without modern software-verification techniques. The community needs a suite of test calculations with analytically, numerically, or at least communally verified results. We therefore offer the Bayesian Atmospheric Radiative Transfer Test Suite, or BARTTest, a collection of tests offered for community use and development.This presentation focuses on Bayesian retrieval. Tests include adding noise to and retrieving the BARTTest forward models using the photometric bandpasses and spectroscopic resolutions of the Spitzer, Hubble, Webb, and larger space telescopes for several model exoplanets. A community-verified test on real data for WASP-12b is also included.BARTTest is open-source software. We propose this test suite as a standard for verifying radiative-transfer codes, analogous to the Held-Suarez test for general circulation models. This work was supported by NASA Planetary Atmospheres grant NX12AI69G and NASA Astrophysics Data Analysis Program grant NNX13AF38G.

  9. BARTTest: Community-Standard Radiative-Transfer Tests I: Forward Models

    Science.gov (United States)

    Himes, Michael D.; Harrington, Joseph; Cubillos, Patricio; Blecic, Jasmina; Challener, Ryan C.

    2017-10-01

    Atmospheric radiative transfer codes are used both to predict planetary spectra and in retrieval algorithms to interpret data. Observational plans, theoretical models, and scientific results thus depend on the correctness of these calculations. Yet, the calculations are complex and the codes implementing them are often written without modern software-verification techniques. The community needs a suite of test calculations with analytically, numerically, or at least communally verified results. We therefore offer the Bayesian Atmospheric Radiative Transfer Test Suite, or BARTTest, a collection of tests offered for community use and development.This presentation focuses on forward models. Tests include a single-line, single layer atmosphere verified by an independent numerical line-broadening code included with the test, an isothermal atmoshere with hundreds of millions of lines (which should emit as a blackbody of the same temperature), and realistic atmospheres verified by an independent radiative transfer model.BARTTest is open-source software. We propose this test suite as a standard for verifying radiative-transfer codes, analogous to the Held-Suarez test for general circulation models. This work was supported by NASA Planetary Atmospheres grant NX12AI69G and NASA Astrophysics Data Analysis Program grant NNX13AF38G.

  10. Evaluating operational specifications of point-of-care diagnostic tests: a standardized scorecard.

    Science.gov (United States)

    Lehe, Jonathan D; Sitoe, Nádia E; Tobaiwa, Ocean; Loquiha, Osvaldo; Quevedo, Jorge I; Peter, Trevor F; Jani, Ilesh V

    2012-01-01

    The expansion of HIV antiretroviral therapy into decentralized rural settings will increasingly require simple point-of-care (POC) diagnostic tests that can be used without laboratory infrastructure and technical skills. New POC test devices are becoming available but decisions around which technologies to deploy may be biased without systematic assessment of their suitability for decentralized healthcare settings. To address this, we developed a standardized, quantitative scorecard tool to objectively evaluate the operational characteristics of POC diagnostic devices. The tool scores devices on a scale of 1-5 across 30 weighted characteristics such as ease of use, quality control, electrical requirements, shelf life, portability, cost and service, and provides a cumulative score that ranks products against a set of ideal POC characteristics. The scorecard was tested on 19 devices for POC CD4 T-lymphocyte cell counting, clinical chemistry or hematology testing. Single and multi-parameter devices were assessed in each of test categories. The scores across all devices ranged from 2.78 to 4.40 out of 5. The tool effectively ranked devices within each category (p0.80; ptechnology. It is particularly relevant for countries and testing programs considering the adoption of new POC diagnostic tests.

  11. Standard practice for verification of constant amplitude dynamic forces in an axial fatigue testing system

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This practice covers procedures for the dynamic verification of cyclic force amplitude control or measurement accuracy during constant amplitude testing in an axial fatigue testing system. It is based on the premise that force verification can be done with the use of a strain gaged elastic element. Use of this practice gives assurance that the accuracies of forces applied by the machine or dynamic force readings from the test machine, at the time of the test, after any user applied correction factors, fall within the limits recommended in Section 9. It does not address static accuracy which must first be addressed using Practices E 4 or equivalent. 1.2 Verification is specific to a particular test machine configuration and specimen. This standard is recommended to be used for each configuration of testing machine and specimen. Where dynamic correction factors are to be applied to test machine force readings in order to meet the accuracy recommended in Section 9, the verification is also specific to the c...

  12. Criterion and convergent validity of the Montreal cognitive assessment with screening and standardized neuropsychological testing.

    Science.gov (United States)

    Lam, Benjamin; Middleton, Laura E; Masellis, Mario; Stuss, Donald T; Harry, Robin D; Kiss, Alex; Black, Sandra E

    2013-12-01

    To compare the validity of the Montreal Cognitive Assessment (MoCA) with the criterion standard of standardized neuropsychological testing and to compare the convergent validity of the MoCA with that of existing screening tools and global measures of cognition. Cross-sectional observational study. Tertiary care hospital-based cognitive neurology subspecialty clinic. A convenience sample of 107 individuals with mild Alzheimer's disease (AD, n=75) or mild cognitive impairment (MCI, n=32) from the Sunnybrook Dementia Study. In addition to the MoCA, all participants completed the Mini-Mental State Examination (MMSE), the Mattis Dementia Rating Scale (DRS), and detailed neuropsychological testing. Convergent validity was supported, with MoCA scores correlating well with the MMSE (correlation coefficient (r)=0.66, Ptests and, in the case of memory (area under the receiver operating characteristic curve (AUC)=0.86), executive (AUC=0.79), and visuospatial function (AUC=0.79), being reasonably sensitive to impairment in those domains. The MoCA is a valid assessment of cognition that shows good agreement with existing screening tools and global measures (convergent validity) and was superior to the MMSE in this regard. The MoCA domain-specific subscores align with performance on more-detailed neuropsychological tests, suggesting not only good criterion validity for the MoCA, but also that it may be useful in guiding further neuropsychological testing. © 2013, Copyright the Authors Journal compilation © 2013, The American Geriatrics Society.

  13. Development of a standardized testing procedure for assessing the irritation potential of occupational skin cleansers.

    Science.gov (United States)

    Elsner, Peter; Seyfarth, Florian; Antonov, Dimitar; John, Swen Malte; Diepgen, Thomas; Schliemann, Sibylle

    2014-03-01

    Frequent skin cleaning fulfils the definition of occupational 'wet work'. Standardized methods are required to assess the irritation potential of workplace cleansers. To develop a standardized procedure for testing the irritation potential of occupational skin cleansers. In this single-blind, single-centre trial in 25 healthy volunteers, the irritation potential of five generic reference cleansers was tested by three-times-daily washing with an automated skin cleaning device for 4 days, and quantification of cumulative skin barrier damage was performed by visual scoring, chromametry, transepidermal water loss TEWL, and corneometry. For two cleansers, reproducibility of the irritancy assessment was assessed. Furthermore, the irritation induced by four commercial workplace skin cleansers was studied. Whereas no significant changes were observed for any of the tested cleansers by either visual scoring or chromametry, significant increases in TEWL and significant decreases in stratum corneum hydration were found for all cleansers. Cleansers differed significantly in their irritation potential. On retesting of two cleansers, the first results were confirmed. Among the four commercial cleansers, one that was claimed to be mild was found to be disproportionally irritant. The presented model for testing cleansing preparations allows a highly controlled, practically relevant and reproducible irritancy assessment of occupational skin cleansers. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Standard test method for radiochemical determination of uranium isotopes in soil by alpha spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of alpha-emitting uranium isotopes in soil. This test method describes one acceptable approach to the determination of uranium isotopes in soil. 1.2 The test method is designed to analyze 10 g of soil; however, the sample size may be varied to 50 g depending on the activity level. This test method may not be able to completely dissolve all forms of uranium in the soil matrix. Studies have indicated that the use of hydrofluoric acid to dissolve soil has resulted in lower values than results using total dissolution by fusion. 1.3 The lower limit of detection is dependent on count time, sample size, detector, background, and tracer yield. The chemical yield averaged 78 % in a single laboratory evaluation, and 66 % in an interlaboratory collaborative study. 1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, ass...

  15. Standardization of serological tests for detecting anti-Trypanosoma cruzi antibodies in dogs

    Directory of Open Access Journals (Sweden)

    M. A. Lauricella

    1993-09-01

    Full Text Available This paper reports on the standardization of four serological reactions currently used in human serodiagnosis for the detection of anti-Trypanosoma cruzi antibodies in naturally and experimentally infected dogs. Indirect immunofluorescence test (IFAT and hemagglutination test (IHAT were standardized, and complement fixation test (CFT and direct agglutination test (DAT were used for diagnostic confirmation. Four hundred and eighty one mongrel dogs that were studied by xenodiagnosis were used: (1 parasitemic dogs of two localities of endemic area (EA of Santiago del Estero province in Argentina (n = 134; (2 non-parasitemic dogs of the same area (n = 285; (3 dogs experimentally infected with T. cruzi in the patent period (n = 6; (4 non-infected dogs (n = 56 which were born in the city of Buenos Aires (BA, one non-EA for Chagas' disease. For IFAT, parasitemic dogs EA showed 95% of reactive sera. Non parasitemic dogs EA showed 77% of non reactive sera. None sera from BA were reactive for dilutions higher than four. For IHAT, 84% of sera of parasitemic dogs EA showed serological reactivity and among non parasitemic dogs BA, 61% were non reactive, while the remainder showed at most titres of 1/16. The cut-off titres for IFAT and IHAT were 1/16 and 1/32 respectively, and for CFT and DAT 1/1 and 1/128 respectively. Sensitivity for IFAT, IHAT, CF and DAT were 95%, 84%, 97% and 95% respectively.

  16. Distortion product otoacoustic emission test performance for a priori criteria and for multifrequency audiometric standards.

    Science.gov (United States)

    Gorga, M P; Neely, S T; Dorn, P A

    1999-08-01

    1) To describe distortion product otoacoustic emission (DPOAE) test performance when a priori response criteria are applied to a large set of DPOAE data. 2) To describe DPOAE test performance when multifrequency definitions of auditory function are used. 3) To determine DPOAE test performance when a single decision regarding auditory status is made for an ear, based on DPOAE data from several frequencies. 4) To compare univariate and multivariate test performance when multifrequency gold standard definitions and response criteria are applied to DPOAE data. DPOAE and audiometric data were analyzed from 1267 ears of 806 subjects. These data were evaluated for three different frequency combinations (2, 3, 4 kHz; 2, 3, 4, 6 kHz; 1.5, 2, 3, 4, 6 kHz). DPOAE data were collected for each of the f2 frequencies listed above, using primary levels (L1/L2) of 65/55 dB SPL and a primary ratio (f2/f1) of 1.22. Sensitivity and specificity were evaluated for signal to noise ratios (SNRs) of 3, 6, and 9 dB, which are in common clinical use. In addition, test performance was evaluated using clinical decision theory, following the convention we have used in previous reports on otoacoustic emission test performance. Both univariate and multivariate analyses techniques were applied to the data. In addition to evaluating DPOAE test performance for the case when audiometric and f2 frequency were equal, multifrequency gold standards and multifrequency criterion responses were evaluated. Three new gold standards were used to assess test performance: average pure-tone thresholds, extrema thresholds that took into account both the magnitude of the loss and the number of frequencies at which hearing loss existed, and a combination of the two. These new gold standards were applied to each of the three frequency groups described above. As expected, SNR criteria of 3, 6, and 9 dB never resulted in perfect DPOAE test performance. Even the most stringent of these criteria (9 dB SNR) did not result

  17. Standard Test Method for Obtaining Char Density Profile of Ablative Materials by Machining and Weighing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This test method covers the determination of the char density profile of a charred ablator that can be used with the following limitations: 1.1.1 The local surface imperfections must be removed, and the char must be able to be machined off in a plane parallel to the char-virgin material interface before the density profiles can be determined. 1.1.2 The char must be strong enough to withstand the machining and handling techniques employed. 1.1.3 The material should have orderly density variations. The total thickness of the char and degradation zone must be larger than the machining thicknesses required. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.2.1 Exception—Certain inch-pound equivalent units are included in parentheses for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establis...

  18. Canadian multicenter laboratory study for standardized second-line antimicrobial susceptibility testing of Mycobacterium tuberculosis.

    Science.gov (United States)

    Sharma, Meenu; Thibert, Louise; Chedore, Pamela; Shandro, Cary; Jamieson, Frances; Tyrrell, Gregory; Christianson, Sara; Soualhine, Hafid; Wolfe, Joyce

    2011-12-01

    The purpose of this study was to establish a standardized protocol for second-line antimicrobial susceptibility testing of Mycobacterium tuberculosis using the Bactec MGIT 960 system in Canadian laboratories. Four Canadian public health laboratories compared the susceptibility testing results of 9 second-line antimicrobials between the Bactec 460 and Bactec MGIT 960 systems. Based on the data generated, we have established that the Bactec MGIT 960 system provides results comparable to those obtained with the previous Bactec 460 method. The critical concentrations established for the testing of the antimicrobials used are as follows: amikacin, 1 μg/ml; capreomycin, 2.5 μg/ml; ethionamide, 5 μg/ml; kanamycin, 2.5 μg/ml; linezolid, 1 μg/ml; moxifloxacin, 0.25 μg/ml; ofloxacin, 2 μg/ml; p-aminosalicylic acid, 4 μg/ml; rifabutin, 0.5 μg/ml.

  19. Canadian Multicenter Laboratory Study for Standardized Second-Line Antimicrobial Susceptibility Testing of Mycobacterium tuberculosis ▿

    Science.gov (United States)

    Sharma, Meenu; Thibert, Louise; Chedore, Pamela; Shandro, Cary; Jamieson, Frances; Tyrrell, Gregory; Christianson, Sara; Soualhine, Hafid; Wolfe, Joyce

    2011-01-01

    The purpose of this study was to establish a standardized protocol for second-line antimicrobial susceptibility testing of Mycobacterium tuberculosis using the Bactec MGIT 960 system in Canadian laboratories. Four Canadian public health laboratories compared the susceptibility testing results of 9 second-line antimicrobials between the Bactec 460 and Bactec MGIT 960 systems. Based on the data generated, we have established that the Bactec MGIT 960 system provides results comparable to those obtained with the previous Bactec 460 method. The critical concentrations established for the testing of the antimicrobials used are as follows: amikacin, 1 μg/ml; capreomycin, 2.5 μg/ml; ethionamide, 5 μg/ml; kanamycin, 2.5 μg/ml; linezolid, 1 μg/ml; moxifloxacin, 0.25 μg/ml; ofloxacin, 2 μg/ml; p-aminosalicylic acid, 4 μg/ml; rifabutin, 0.5 μg/ml. PMID:21998413

  20. Standard test method for determination of "microwave safe for reheating" for ceramicware

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method determines the suitability of ceramicware for use in microwave re-heating applications. Microwave ovens are mainly used for reheating and defrosting frozen foods. Severe thermal conditions can occur while reheating foods. Typical reheating of foods requires one to five min. in the microwave at the highest power settings. Longer periods than five minutes are considered cooking. Cooking test methods and standards are not addressed in this test method. Most ceramicware is minimally absorbing of the microwave energy and will not heat up significantly. Unfortunately there are some products that absorb microwave energy to a greater extent and can become very hot in the microwave and pose a serious hazard. Additionally, the nature of microwave heating introduces radiation in a non-uniform manner producing temperature differentials in the food being cooked as well as the ceramic container holding it. The differential may become great enough to thermal shock the ware and create dangerous condition...

  1. Standard test methods for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of uranium hexafluoride

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These test methods cover procedures for subsampling and for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of uranium hexafluoride UF6. Most of these test methods are in routine use to determine conformance to UF6 specifications in the Enrichment and Conversion Facilities. 1.2 The analytical procedures in this document appear in the following order: Note 1—Subcommittee C26.05 will confer with C26.02 concerning the renumbered section in Test Methods C761 to determine how concerns with renumbering these sections, as analytical methods are replaced with stand-alone analytical methods, are best addressed in subsequent publications. Sections Subsampling of Uranium Hexafluoride 7 - 10 Gravimetric Determination of Uranium 11 - 19 Titrimetric Determination of Uranium 20 Preparation of High-Purity U3O 8 21 Isotopic Analysis 22 Isotopic Analysis by Double-Standard Mass-Spectrometer Method 23 - 29 Determination of Hydrocarbons, Chlorocarbons, and Partially Substitut...

  2. The Standardized Field Sobriety Tests: a review of scientific and legal issues.

    Science.gov (United States)

    Rubenzer, Steven J

    2008-08-01

    This article details the history and development of the National Highway and Safety Administration's Standardized Field Sobriety Tests. They are reviewed in terms of relevant scientific, psychometric, and legal issues. It is concluded that the research that supports their use is limited, important confounding variables have not been thoroughly studied, reliability is mediocre, and that their developers and prosecution-oriented publications have oversold the tests. Further, case law since their development has severed the tests from their validation data, so that they are not admissible on the criterion for which they were validated (blood alcohol concentration), and admissible for a criterion for which they were not (mental, physical, or driving impairment). Directions for further research are presented.

  3. Thermal cycling for restorative materials: does a standardized protocol exist in laboratory testing? A literature review.

    Science.gov (United States)

    Morresi, Anna Lucia; D'Amario, Maurizio; Capogreco, Mario; Gatto, Roberto; Marzo, Giuseppe; D'Arcangelo, Camillo; Monaco, Annalisa

    2014-01-01

    In vitro tests continue to be an indispensable method for the initial screening of dental materials. Thermal cycling is one of the most widely used procedures to simulate the physiological aging experienced by biomaterials in clinical practice. Consequently it is routinely employed in experimental studies to evaluate materials' performance. A literature review aimed to elucidate test parameters for in vitro aging of adhesive restorations was performed. This study aims to assess whether or not a standardized protocol of thermal cycling has been acknowledged from a review of the literature. An exhaustive literature search, examining the effect of thermal cycling on restorative dental materials, was performed with electronic database and by hand. The search was restricted to studies published from 1998 to August 2013. No language restrictions were applied. The search identified 193 relevant experimental studies. Only twenty-three studies had faithfully applied ISO standard. The majority of studies used their own procedures, showing only a certain consistency within the temperature parameter (5-55°C) and a great variability in the number of cycles and dwell time chosen. A wide variation in thermal cycling parameters applied in experimental studies has been identified. The parameters selected amongst these studies seem to be done on the basis of convenience for the authors in most cases. A comparison of results between studies would appear to be impossible. The available data suggest that further investigations will be required to ultimately develop a standardized thermal cycling protocol. © 2013 Elsevier Ltd. All rights reserved.

  4. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Titanium

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers procedures for measuring reaction rates by the activation reactions 46Ti(n,p) 46Sc + 47Ti(n, np)46Sc. Note 1—Since the cross section for the (n,np) reaction is relatively small for energies less than 12 MeV and is not easily distinguished from that of the (n,p) reaction, this test method will refer to the (n,p) reaction only. 1.2 The reaction is useful for measuring neutrons with energies above approximately 4.4 MeV and for irradiation times up to about 250 days (for longer irradiations, see Practice E 261). 1.3 With suitable techniques, fission-neutron fluence rates above 109 cm–2·s–1 can be determined. However, in the presence of a high thermal-neutron fluence rate, 46Sc depletion should be investigated. 1.4 Detailed procedures for other fast-neutron detectors are referenced in Practice E 261. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all...

  5. A standard test of heat-pain responses using CASE IV.

    Science.gov (United States)

    Dyck, P J; Zimmerman, I R; Johnson, D M; Gillen, D; Hokanson, J L; Karnes, J L; Gruener, G; O'Brien, P C

    1996-03-01

    Heat-pain threshold and stimulus response characteristics can be evaluated with graduated heating pulses from a radiant heat source or a contact thermode. Results may be used to: (1) evaluate differences in sensation among anatomical sites, sides of the body, and with development and aging; and (2) provide an end-point for the study of the efficacy of drugs; or to follow the course of sensory alteration in disease (medical practice, epidemiologic studies, and controlled clinical trials). Because there is great variability in how tests of this kind are performed and scored, comparisons of results among medical centers are difficult. To meet this need, we have developed, and here describe, a standardized and validated test of heat-pain. We use both pyramidal and trapezoid-shaped stimuli. The range of stimulus magnitudes we recommend is sufficient to test heat-pain at a sensitive region (the face) of young people and an insensitive region (the foot) of healthy old people. From tests on healthy subjects and patients, we find that neither our previously published forced-choice or 4, 2, and 1 stepping algorithms are suitable for testing heat-pain sensation. We, therefore, introduce the Non-Repeating Ascending with Null Stimuli (NRA-NS) algorithm which performs satisfactorily. The graphed data points of responses to increasingly stronger heat pulses were made up of two components-the no pain (0) response line and the heat-pain response line (> or = 1 numerical scaling of the pain responses graded from 1 [least] to 10 [greatest]). For the pain responses, we found that usually a curve could be fit using a quadratic equation. Using this equation, or interpolation where necessary, it is possible to compute the heat-pain detection threshold (HPDT or HP:0.5), an intermediate heat-pain response (HP:5.0), and the difference between the two (HP:5.0-0.5). Our studies show that a certain time is needed between successive stimuli and tests to minimize changing basal skin temperature

  6. Opportunity to learn: Investigating possible predictors for pre-course Test Of Astronomy STandards TOAST scores

    Science.gov (United States)

    Berryhill, Katie J.

    As astronomy education researchers become more interested in experimentally testing innovative teaching strategies to enhance learning in introductory astronomy survey courses ("ASTRO 101"), scholars are placing increased attention toward better understanding factors impacting student gain scores on the widely used Test Of Astronomy STandards (TOAST). Usually used in a pre-test and post-test research design, one might naturally assume that the pre-course differences observed between high- and low-scoring college students might be due in large part to their pre-existing motivation, interest, experience in science, and attitudes about astronomy. To explore this notion, 11 non-science majoring undergraduates taking ASTRO 101 at west coast community colleges were interviewed in the first few weeks of the course to better understand students' pre-existing affect toward learning astronomy with an eye toward predicting student success. In answering this question, we hope to contribute to our understanding of the incoming knowledge of students taking undergraduate introductory astronomy classes, but also gain insight into how faculty can best meet those students' needs and assist them in achieving success. Perhaps surprisingly, there was only weak correlation between students' motivation toward learning astronomy and their pre-test scores. Instead, the most fruitful predictor of TOAST pre-test scores was the quantity of pre-existing, informal, self-directed astronomy learning experiences.

  7. Mechanical waves conceptual survey: Its modification and conversion to a standard multiple-choice test

    Directory of Open Access Journals (Sweden)

    Pablo Barniol

    2016-02-01

    Full Text Available In this article we present several modifications of the mechanical waves conceptual survey, the most important test to date that has been designed to evaluate university students’ understanding of four main topics in mechanical waves: propagation, superposition, reflection, and standing waves. The most significant changes are (i modification of several test questions that had some problems in their original design, (ii standardization of the number of options for each question to five, (iii conversion of the two-tier questions to multiple-choice questions, and (iv modification of some questions to make them independent of others. To obtain a final version of the test, we administered both the original and modified versions several times to students at a large private university in Mexico. These students were completing a course that covers the topics tested by the survey. The final modified version of the test was administered to 234 students. In this study we present the modifications for each question, and discuss the reasons behind them. We also analyze the results obtained by the final modified version and offer a comparison between the original and modified versions. In the Supplemental Material we present the final modified version of the test. It can be used by teachers and researchers to assess students’ understanding of, and learning about, mechanical waves.

  8. Standardization, Clinical Validation, and Typicality Norms of a New Test Assessing Semantic Verbal Fluency.

    Science.gov (United States)

    Quaranta, Davide; Caprara, Alessia; Piccininni, Chiara; Vita, Maria G; Gainotti, Guido; Marra, Camillo

    2016-08-01

    Semantic verbal fluency (SVF) tests are widely used in clinical neuropsychology. We propose the standardization and clinical validation of a new SVF test based on the production of names of birds and articles of furniture (Birds and Articles of Furniture test-BAF). A sample of 268 subjects aged 40 years or more underwent the test. The clinical validation was conducted on subjects affected by amnesic Mild Cognitive Impairment (aMCI; N = 106), mild (N = 178), and moderate (N = 114) Alzheimer's disease (AD). The BAF total score was influenced by both age and education, whereas the single scores obtained on BAF were also influenced by gender. The percentage of subjects with pathological score on BAF increased from aMCI (19%) to mild (45.5%) and moderate (71.1%) AD, and receiver operating characteristic curves analysis showed that the BAF may be highly reliable in distinguishing aMCI and AD patients from healthy subjects. We also provide typicality norms for birds and articles of furniture that could be useful in the assessment of qualitative features of words produced in semantic fluency tests. The BAF test could be a valid and reliable tool in both clinical practice and research on subjects affected by cognitive impairment. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  9. Precision tests of the Standard Model with Kaon decays at CERN

    Science.gov (United States)

    Lamanna, G.; Ambrosino, F.; Antonelli, A.; Anzivino, G.; Arcidiacono, R.; Baldini, W.; Balev, S.; Batley, J. R.; Behler, M.; Bifani, S.; Biino, C.; Bizzeti, A.; Bloch-Devaux, B.; Bocquet, G.; Bolotov, V.; Bucci, F.; Cabibbo, N.; Calvetti, M.; Cartiglia, N.; Ceccucci, A.; Cenci, P.; Cerri, C.; Cheshkov, C.; Chèze, J. B.; Clemencic, M.; Collazuol, G.; Costantini, F.; Cotta Ramusino, A.; Coward, D.; Cundy, D.; Dabrowski, A.; D'Agostini, G.; Dalpiaz, P.; Damiani, C.; Danielsson, H.; De Beer, M.; Dellacasa, G.; Derré, J.; Dibon, H.; Di Filippo, D.; DiLella, L.; Doble, N.; Duk, V.; Engelfried, J.; Eppard, K.; Falaleev, V.; Fantechi, R.; Fidecaro, M.; Fiorini, L.; Fiorini, M.; Fonseca Martin, T.; Frabetti, P. L.; Fucci, A.; Gallorini, S.; Gatignon, L.; Gersabeck, E.; Gianoli, A.; Giudici, S.; Gonidec, A.; Goudzovski, E.; Goy Lopez, S.; Gushchin, E.; Hallgren, B.; Hita-Hochgesand, M.; Holder, M.; Hristov, P.; Iacopini, E.; Imbergamo, E.; Jeitler, M.; Kalmus, G.; Kekelidze, V.; Kleinknecht, K.; Kozhuharov, V.; Kubischta, W.; Kurshetsov, V.; Lamanna, G.; Lazzeroni, C.; Lenti, M.; Leonardi, E.; Litov, L.; Madigozhin, D.; Maier, A.; Mannelli, I.; Marchetto, F.; Marel, G.; Markytan, M.; Marouelli, P.; Martini, M.; Masetti, L.; Massarotti, P.; Mazzucato, E.; Michetti, A.; Mikulec, I.; Misheva, M.; Molokanova, N.; Monnier, E.; Moosbrugger, U.; Morales Morales, C.; Moulson, M.; Movchan, S.; Munday, D. J.; Napolitano, M.; Nappi, A.; Neuhofer, G.; Norton, A.; Numao, T.; Obraztsov, V.; Palladino, V.; Patel, M.; Pepe, M.; Peters, A.; Petrucci, F.; Petrucci, M. C.; Peyaud, B.; Piandani, R.; Piccini, M.; Pierazzini, G.; Polenkevich, I.; Popov, I.; Potrebenikov, Yu.; Raggi, M.; Renk, B.; Retière, F.; Riedler, P.; Romano, A.; Rubin, P.; Ruggiero, G.; Salamon, A.; Saracino, G.; Savrié, M.; Scarpa, M.; Semenov, V.; Sergi, A.; Serra, M.; Shieh, M.; Shkarovskiy, S.; Slater, M. W.; Sozzi, M.; Spadaro, T.; Stoynev, S.; Swallow, E.; Szleper, M.; Valdata-Nappi, M.; Valente, P.; Vallage, B.; Velasco, M.; Veltri, M.; Venditti, S.; Wache, M.; Wahl, H.; Walker, A.; Wanke, R.; Widhalm, L.; Winhart, A.; Winston, R.; Wood, M. D.; Wotton, S. A.; Yushchenko, O.; Zinchenko, A.; Ziolkowski, M.; NA48/2 Collaboration; NA62 Collaboration

    2016-04-01

    Effects of new physics in flavor could be found both in Flavor Changing Neutral Current (FCNC) processes and in Lepton Flavor Violation (LFV) modes. The former offer the possibility to deeply test the standard model in a clean environment, while the latter are sensitive to contribution from several models beyond the standard model. In the Kaon sector both FCNC and LFV will be investigated in the NA62 experiment. In addition the kaons sector is an ideal place where to look for new particles and tiny effects, in the region of hundreds of MeV/c2. In this paper prospects for exotic searches in NA62 will be presented, together with recent results from NA48/2 and NA62-RK on LFV kaon decays modes.

  10. The achievement impact of the inclusion model on the standardized test scores of general education students

    Science.gov (United States)

    Garrett-Rainey, Syrena

    The purpose of this study was to compare the achievement of general education students within regular education classes to the achievement of general education students in inclusion/co-teach classes to determine whether there was a significant difference in the achievement between the two groups. The school district's inclusion/co-teach model included ongoing professional development support for teachers and administrators. General education teachers, special education teachers, and teacher assistants collaborated to develop instructional strategies to provide additional remediation to help students to acquire the skills needed to master course content. This quantitative study reviewed the end-of course test (EoCT) scores of Grade 10 physical science and math students within an urban school district. It is not known whether general education students in an inclusive/co-teach science or math course will demonstrate a higher achievement on the EoCT in math or science than students not in an inclusive/co-teach classroom setting. In addition, this study sought to determine if students classified as low socioeconomic status benefited from participating in co-teaching classrooms as evidenced by standardized tests. Inferential statistics were used to determine whether there was a significant difference between the achievements of the treatment group (inclusion/co-teach) and the control group (non-inclusion/co-teach). The findings can be used to provide school districts with optional instructional strategies to implement in the diverse classroom setting in the modern classroom to increase academic performance on state standardized tests.

  11. Examination of a Standardized Test for Evaluating the Degree of Cure of EVA Encapsulation: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Miller, D. C.; Gu, X.; Haldenman, S.; Hidalgo, M.; Malguth, E.; Reid, C. G.; Shioda, T.; Schulze, S. H.; Wang, Z. Y.; Wohlgemuth, J. H.

    2013-11-01

    The curing of cross-linkable encapsulation is a critical consideration for photovoltaic (PV) modules manufactured using a lamination process. Concerns related to ethylene-co-vinyl acetate (EVA) include the quality (e.g., expiration and uniformity) of the films or completion (duration) of the cross-linking of the EVA within a laminator. Because these issues are important to both EVA and module manufacturers, an international standard has recently been proposed by the Encapsulation Task-Group within the Working Group 2 (WG2) of the International Electrotechnical Commission (IEC) Technical Committee 82 (TC82) for the quantification of the degree of cure for EVA encapsulation. The present draft of the standard calls for the use of differential scanning calorimetry (DSC) as the rapid, enabling secondary (test) method. Both the residual enthalpy- and melt/freeze-DSC methods are identified. The DSC methods are calibrated against the gel content test, the primary (reference) method. Aspects of other established methods, including indentation and rotor cure metering, were considered by the group. Key details of the test procedure will be described.

  12. Standard practices for verification of displacement measuring systems and devices used in material testing machines

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 These practices cover procedures and requirements for the calibration and verification of displacement measuring systems by means of standard calibration devices for static and quasi-static testing machines. This practice is not intended to be complete purchase specifications for testing machines or displacement measuring systems. Displacement measuring systems are not intended to be used for the determination of strain. See Practice E83. 1.2 These procedures apply to the verification of the displacement measuring systems associated with the testing machine, such as a scale, dial, marked or unmarked recorder chart, digital display, etc. In all cases the buyer/owner/user must designate the displacement-measuring system(s) to be verified. 1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems m...

  13. Construction, validation, and derivation of performance standards for a fitness test for correctional officer applicants.

    Science.gov (United States)

    Jamnik, Veronica K; Thomas, Scott G; Burr, Jamie F; Gledhill, Norman

    2010-02-01

    The purpose of this investigation was to develop and validate a fitness test for correctional officer (CO) applicants (FITCO) and to establish associated standards of acceptability. The FITCO incorporated the most important, physically demanding, and frequently occurring tasks of a CO. It consists of (i) a simulated cell search; (ii) an emergency response circuit (ERC), involving a 60-m run while scaling 4 sets of stairs, followed by simulations of an inmate control, wrist restraint, arm retraction, and 40-m mannequin drag; and (iii) a test of aerobic fitness. The validity of the FITCO was established by very high congruence between the oxygen consumption, heart rate, and rating of perceived exertion of incumbent COs while performing the ERC with the same measurements while COs were performing the on-the-job tasks on which the ERC was based. The content validity of the FITCO was confirmed by very high Likert ratings (>6 on a 7-point scale) by both male and female incumbent COs of all ages concerning the importance, relatedness, physical demands, and overall appropriateness of the FITCO for evaluating CO applicants. We conclude that because the forces built into the ERC and the FITCO standards were both derived from the performance of safe and efficient incumbent female COs of all ages, and both the validity and test-retest reliability (intraclass correllation coefficient = 0.977) of the FITCO are very high, the FITCO was properly constructed to meet the requirements of the Supreme Court of Canada's Meiorin Decision.

  14. Near-infrared fluorescence image quality test methods for standardized performance evaluation

    Science.gov (United States)

    Kanniyappan, Udayakumar; Wang, Bohan; Yang, Charles; Ghassemi, Pejhman; Wang, Quanzeng; Chen, Yu; Pfefer, Joshua

    2017-03-01

    Near-infrared fluorescence (NIRF) imaging has gained much attention as a clinical method for enhancing visualization of cancers, perfusion and biological structures in surgical applications where a fluorescent dye is monitored by an imaging system. In order to address the emerging need for standardization of this innovative technology, it is necessary to develop and validate test methods suitable for objective, quantitative assessment of device performance. Towards this goal, we develop target-based test methods and investigate best practices for key NIRF imaging system performance characteristics including spatial resolution, depth of field and sensitivity. Characterization of fluorescence properties was performed by generating excitation-emission matrix properties of indocyanine green and quantum dots in biological solutions and matrix materials. A turbid, fluorophore-doped target was used, along with a resolution target for assessing image sharpness. Multi-well plates filled with either liquid or solid targets were generated to explore best practices for evaluating detection sensitivity. Overall, our results demonstrate the utility of objective, quantitative, target-based testing approaches as well as the need to consider a wide range of factors in establishing standardized approaches for NIRF imaging system performance.

  15. Comparison of the CLSI guideline and ISO/IDF standard for antimicrobial susceptibility testing of Lactobacilli.

    Science.gov (United States)

    Mayrhofer, Sigrid; Zitz, Ulrike; Birru, Firew H; Gollan, Dagmar; Gołoś, Aleksandra K; Kneifel, Wolfgang; Domig, Konrad J

    2014-12-01

    Lactobacilli play a crucial role as probiotics and as starter cultures in the production of fermented foods. Although lactobacilli are a technologically useful and beneficial group of bacteria, a few members of them have been rarely correlated with bacterial infections. Correspondingly, clinicians are interested in the antimicrobial susceptibility of lactobacilli. In addition, antimicrobial susceptibility testing (AST) is also relevant for commercially applied lactobacilli as bacterial strains harboring transferable antibiotic resistance genes should not be used in fermented and probiotic foods. Therefore, two methods were developed by different organizations, which were compared within this study. For this purpose, 22 Lactobacillus-type strains were tested for their antimicrobial susceptibility to 16 antibiotics following the procedures of the Clinical and Laboratory Standards Institute (CLSI) and the International Organization of Standardization (ISO)/International Dairy Federation (IDF). Crucial discrepancies between both procedures were detected mainly due to the different AST media. Hence, half of the strains tested did not consistently grow in the CLSI medium, whereas all showed evaluable growth in the ISO/IDF medium. However, some antibiotics were influenced by the latter medium. In particular, low levels of essential agreement between both methods were obtained with seven antibiotics. Accordingly, different interpretative criteria are needed for both procedures to distinguish resistant from susceptible strains.

  16. Examination of a Standardized Test for Evaluating the Degree of Cure of EVA Encapsulation (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Miller, D.; Wohlgemuth, J.; Gu, X.; Haldeman, S.; Hidalgo, M.; Malguth, E.; Reid, C.; Shioda, T.; Schulze, S.; Wang, Z.

    2013-11-01

    The curing of cross-linkable encapsulation is a critical consideration for photovoltaic (PV) modules manufactured using a lamination process. Concerns related to ethylene-co-vinyl acetate (EVA) include the quality (e.g., expiration and uniformity) of the films or completion (duration) of the cross-linking of the EVA within a laminator. Because these issues are important to both EVA and module manufacturers, an international standard has recently been proposed by the Encapsulation Task-Group within the Working Group 2 (WG2) of the International Electrotechnical Commission (IEC) Technical Committee 82 (TC82) for the quantification of the degree of cure for EVA encapsulation. The present draft of the standard calls for the use of differential scanning calorimetry (DSC) as the rapid, enabling secondary (test) method. Both the residual enthalpy- and melt/freeze-DSC methods are identified. The DSC methods are calibrated against the gel content test, the primary (reference) method. Aspects of other established methods, including indentation and rotor cure metering, were considered by the group. Key details of the test procedure will be described.

  17. Everyday uses of standardized test information in a geriatric setting: a qualitative study exploring occupational therapist and physiotherapist test administrators’ justifications

    Science.gov (United States)

    2014-01-01

    Background Health professionals are required to collect data from standardized tests when assessing older patients’ functional ability. Such data provide quantifiable documentation on health outcomes. Little is known, however, about how physiotherapists and occupational therapists who administer standardized tests use test information in their daily clinical work. This article aims to investigate how test administrators in a geriatric setting justify the everyday use of standardized test information. Methods Qualitative study of physiotherapists and occupational therapists on two geriatric hospital wards in Norway that routinely tested their patients with standardized tests. Data draw on seven months of fieldwork, semi-structured interviews with eight physiotherapists and six occupational therapists (12 female, two male), as well as observations of 26 test situations. Data were analyzed using Systematic Text Condensation. Results We identified two test information components in everyday use among physiotherapist and occupational therapist test administrators. While the primary component drew on the test administrators’ subjective observations during testing, the secondary component encompassed the communication of objective test results and test performance. Conclusions The results of this study illustrate the overlap between objective and subjective data in everyday practice. In clinical practice, by way of the clinicians’ gaze on how the patient functions, the subjective and objective components of test information are merged, allowing individual characteristics to be noticed and made relevant as test performance justifications and as rationales in the overall communication of patient needs. PMID:24528609

  18. Multicultural Art Education in an Era of Standardized Testing: Changes in Knowledge and Skill for Art Teacher Certification in Texas

    Science.gov (United States)

    Kraehe, Amelia

    2010-01-01

    This article explores changes in multicultural knowledge and skill to which beginning art teachers are held accountable through standardized teacher testing in Texas. Standardized testing of preservice art teachers' knowledge and skill has been the basis of the state's certification of beginning art teachers and accreditation of art teacher…

  19. "If I'm so Smart..": Memories of Assessment and the Role of Standardized Testing in Forming an Intellectual Identity

    Science.gov (United States)

    McNutt, Stephen Bishop

    2014-01-01

    Written at a time when the number of students taking standardized tests in U.S. public schools is at an all-time high, this dissertation presents and analyzes the contribution of standardized testing to intellectual identity formation as portrayed within the oral histories of four adults from the post-"A Nation at Risk" (1983) and…

  20. A National Survey of Middle and High School Science Teachers' Responses to Standardized Testing: Is Science Being Devalued in Schools?

    Science.gov (United States)

    Aydeniz, Mehmet; Southerland, Sherry A.

    2012-01-01

    This study explored American high school and middle school science teachers' attitudes toward the use of standardized testing for accountability purposes, their justification for the attitudes they hold and the impact of standardized testing on their instructional and assessment practices. A total of 161 science teachers participated in the study.…