WorldWideScience

Sample records for psa computer code

  1. Improvement of level-1 PSA computer code package

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Woon; Park, C. K.; Kim, K. Y.; Han, S. H.; Jung, W. D.; Chang, S. C.; Yang, J. E.; Sung, T. Y.; Kang, D. I.; Park, J. H.; Lee, Y. H.; Kim, S. H.; Hwang, M. J.; Choi, S. Y.

    1997-07-01

    This year the fifth (final) year of the phase-I of the Government-sponsored Mid- and Long-term Nuclear Power Technology Development Project. The scope of this subproject titled on `The improvement of level-1 PSA Computer Codes` is divided into two main activities : (1) improvement of level-1 PSA methodology, (2) development of applications methodology of PSA techniques to operations and maintenance of nuclear power plant. Level-1 PSA code KIRAP is converted to PC-Windows environment. For the improvement of efficiency in performing PSA, the fast cutset generation algorithm and an analytical technique for handling logical loop in fault tree modeling are developed. Using about 30 foreign generic data sources, generic component reliability database (GDB) are developed considering dependency among source data. A computer program which handles dependency among data sources are also developed based on three stage bayesian updating technique. Common cause failure (CCF) analysis methods are reviewed and CCF database are established. Impact vectors can be estimated from this CCF database. A computer code, called MPRIDP, which handles CCF database are also developed. A CCF analysis reflecting plant-specific defensive strategy against CCF event is also performed. A risk monitor computer program, called Risk Monster, are being developed for the application to the operation and maintenance of nuclear power plant. The PSA application technique is applied to review the feasibility study of on-line maintenance and to the prioritization of in-service test (IST) of motor-operated valves (MOV). Finally, the root cause analysis (RCA) and reliability-centered maintenance (RCM) technologies are adopted and applied to the improvement of reliability of emergency diesel generators (EDG) of nuclear power plant. To help RCA and RCM analyses, two software programs are developed, which are EPIS and RAM Pro. (author). 129 refs., 20 tabs., 60 figs.

  2. Improvement of level-1 PSA computer code package

    International Nuclear Information System (INIS)

    Kim, Tae Woon; Park, C. K.; Kim, K. Y.; Han, S. H.; Jung, W. D.; Chang, S. C.; Yang, J. E.; Sung, T. Y.; Kang, D. I.; Park, J. H.; Lee, Y. H.; Kim, S. H.; Hwang, M. J.; Choi, S. Y.

    1997-07-01

    This year the fifth (final) year of the phase-I of the Government-sponsored Mid- and Long-term Nuclear Power Technology Development Project. The scope of this subproject titled on 'The improvement of level-1 PSA Computer Codes' is divided into two main activities : 1) improvement of level-1 PSA methodology, 2) development of applications methodology of PSA techniques to operations and maintenance of nuclear power plant. Level-1 PSA code KIRAP is converted to PC-Windows environment. For the improvement of efficiency in performing PSA, the fast cutset generation algorithm and an analytical technique for handling logical loop in fault tree modeling are developed. Using about 30 foreign generic data sources, generic component reliability database (GDB) are developed considering dependency among source data. A computer program which handles dependency among data sources are also developed based on three stage bayesian updating technique. Common cause failure (CCF) analysis methods are reviewed and CCF database are established. Impact vectors can be estimated from this CCF database. A computer code, called MPRIDP, which handles CCF database are also developed. A CCF analysis reflecting plant-specific defensive strategy against CCF event is also performed. A risk monitor computer program, called Risk Monster, are being developed for the application to the operation and maintenance of nuclear power plant. The PSA application technique is applied to review the feasibility study of on-line maintenance and to the prioritization of in-service test (IST) of motor-operated valves (MOV). Finally, the root cause analysis (RCA) and reliability-centered maintenance (RCM) technologies are adopted and applied to the improvement of reliability of emergency diesel generators (EDG) of nuclear power plant. To help RCA and RCM analyses, two software programs are developed, which are EPIS and RAM Pro. (author). 129 refs., 20 tabs., 60 figs

  3. Improvement of Level-1 PSA computer code package -A study for nuclear safety improvement-

    International Nuclear Information System (INIS)

    Park, Chang Kyu; Kim, Tae Woon; Ha, Jae Joo; Han, Sang Hoon; Cho, Yeong Kyun; Jeong, Won Dae; Jang, Seung Cheol; Choi, Young; Seong, Tae Yong; Kang, Dae Il; Hwang, Mi Jeong; Choi, Seon Yeong; An, Kwang Il

    1994-07-01

    This year is the second year of the Government-sponsored Mid- and Long-Term Nuclear Power Technology Development Project. The scope of this subproject titled on 'The Improvement of Level-1 PSA Computer Codes' is divided into three main activities : (1) Methodology development on the under-developed fields such as risk assessment technology for plant shutdown and external events, (2) Computer code package development for Level-1 PSA, (3) Applications of new technologies to reactor safety assessment. At first, in the area of PSA methodology development, foreign PSA reports on shutdown and external events have been reviewed and various PSA methodologies have been compared. Level-1 PSA code KIRAP and CCF analysis code COCOA are converted from KOS to Windows. Human reliability database has been also established in this year. In the area of new technology applications, fuzzy set theory and entropy theory are used to estimate component life and to develop a new measure of uncertainty importance. Finally, in the field of application study of PSA technique to reactor regulation, a strategic study to develop a dynamic risk management tool PEPSI and the determination of inspection and test priority of motor operated valves based on risk importance worths have been studied. (Author)

  4. Investigation of the efficiency and qualification of computer codes for PSA

    International Nuclear Information System (INIS)

    Andernacht, M.; Dinsmore, S.

    1992-01-01

    An international selection of computer codes for the quantification of level 1 PSA models was evaluated due to the consistence of results of different Benchmark exercises. The exercises in this project are based on those developed during the first benchmark project (Phase I). Due to several large differences in the results during Phase I of the Benchmark, the exercises in Phase II were more precisely defined. Due to the improved definition of the benchmark exercises, the results delivered from the different computer codes for Phase II are much more consistent. In general, the results of Benchmark II show, that the exercises were defined well enough to allow consistant results to be generated. Thus, the exercises can also be used to support the evaluation of additional PSA programs. (orig.) [de

  5. Research on the improvement of nuclear safety -Improvement of level 1 PSA computer code package-

    International Nuclear Information System (INIS)

    Park, Chang Kyoo; Kim, Tae Woon; Kim, Kil Yoo; Han, Sang Hoon; Jung, Won Dae; Jang, Seung Chul; Yang, Joon Un; Choi, Yung; Sung, Tae Yong; Son, Yung Suk; Park, Won Suk; Jung, Kwang Sub; Kang Dae Il; Park, Jin Heui; Hwang, Mi Jung; Hah, Jae Joo

    1995-07-01

    This year is the third year of the Government-sponsored mid- and long-term nuclear power technology development project. The scope of this sub project titled on 'The improvement of level-1 PSA computer codes' is divided into three main activities : (1) Methodology development on the underdeveloped fields such as risk assessment technology for plant shutdown and low power situations, (2) Computer code package development for level-1 PSA, (3) Applications of new technologies to reactor safety assessment. At first, in this area of shutdown risk assessment technology development, plant outage experiences of domestic plants are reviewed and plant operating states (POS) are decided. A sample core damage frequency is estimated for over draining event in RCS low water inventory i.e. mid-loop operation. Human reliability analysis and thermal hydraulic support analysis are identified to be needed to reduce uncertainty. Two design improvement alternatives are evaluated using PSA technique for mid-loop operation situation: one is use of containment spray system as backup of shutdown cooling system and the other is installation of two independent level indication system. Procedure change is identified more preferable option to hardware modification in the core damage frequency point of view. Next, level-1 PSA code KIRAP is converted to PC-windows environment. For the improvement of efficiency in performing PSA, the fast cutest generation algorithm and an analytical technique for handling logical loop in fault tree modeling are developed. 48 figs, 15 tabs, 59 refs. (Author)

  6. Research on the improvement of nuclear safety -Improvement of level 1 PSA computer code package-

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chang Kyoo; Kim, Tae Woon; Kim, Kil Yoo; Han, Sang Hoon; Jung, Won Dae; Jang, Seung Chul; Yang, Joon Un; Choi, Yung; Sung, Tae Yong; Son, Yung Suk; Park, Won Suk; Jung, Kwang Sub; Kang Dae Il; Park, Jin Heui; Hwang, Mi Jung; Hah, Jae Joo [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-07-01

    This year is the third year of the Government-sponsored mid- and long-term nuclear power technology development project. The scope of this sub project titled on `The improvement of level-1 PSA computer codes` is divided into three main activities : (1) Methodology development on the underdeveloped fields such as risk assessment technology for plant shutdown and low power situations, (2) Computer code package development for level-1 PSA, (3) Applications of new technologies to reactor safety assessment. At first, in this area of shutdown risk assessment technology development, plant outage experiences of domestic plants are reviewed and plant operating states (POS) are decided. A sample core damage frequency is estimated for over draining event in RCS low water inventory i.e. mid-loop operation. Human reliability analysis and thermal hydraulic support analysis are identified to be needed to reduce uncertainty. Two design improvement alternatives are evaluated using PSA technique for mid-loop operation situation: one is use of containment spray system as backup of shutdown cooling system and the other is installation of two independent level indication system. Procedure change is identified more preferable option to hardware modification in the core damage frequency point of view. Next, level-1 PSA code KIRAP is converted to PC-windows environment. For the improvement of efficiency in performing PSA, the fast cutest generation algorithm and an analytical technique for handling logical loop in fault tree modeling are developed. 48 figs, 15 tabs, 59 refs. (Author).

  7. Development of the fire PSA methodology and the fire analysis computer code system

    International Nuclear Information System (INIS)

    Katsunori, Ogura; Tomomichi, Ito; Tsuyoshi, Uchida; Yusuke, Kasagawa

    2009-01-01

    Fire PSA methodology has been developed and was applied to NPPs in Japan for power operation and LPSD states. CDFs of preliminary fire PSA for power operation were the higher than that of internal events. Fire propagation analysis code system (CFAST/FDS Network) was being developed and verified thru OECD-PRISME Project. Extension of the scope for LPSD state is planned to figure out the risk level. In order to figure out the fire risk level precisely, the enhancement of the methodology is planned. Verification and validation of phenomenological fire propagation analysis code (CFAST/FDS Network) in the context of Fire PSA. Enhancement of the methodology such as an application of 'Electric Circuit Analysis' in NUREG/CR-6850 and related tests in order to quantify the hot-short effect precisely. Development of seismic-induced fire PSA method being integration of existing seismic PSA and fire PSA methods is ongoing. Fire PSA will be applied to review the validity of fire prevention and mitigation measures

  8. Computer codes for level 1 probabilistic safety assessment

    International Nuclear Information System (INIS)

    1990-06-01

    Probabilistic Safety Assessment (PSA) entails several laborious tasks suitable for computer codes assistance. This guide identifies these tasks, presents guidelines for selecting and utilizing computer codes in the conduct of the PSA tasks and for the use of PSA results in safety management and provides information on available codes suggested or applied in performing PSA in nuclear power plants. The guidance is intended for use by nuclear power plant system engineers, safety and operating personnel, and regulators. Large efforts are made today to provide PC-based software systems and PSA processed information in a way to enable their use as a safety management tool by the nuclear power plant overall management. Guidelines on the characteristics of software needed for management to prepare a software that meets their specific needs are also provided. Most of these computer codes are also applicable for PSA of other industrial facilities. The scope of this document is limited to computer codes used for the treatment of internal events. It does not address other codes available mainly for the analysis of external events (e.g. seismic analysis) flood and fire analysis. Codes discussed in the document are those used for probabilistic rather than for phenomenological modelling. It should be also appreciated that these guidelines are not intended to lead the user to selection of one specific code. They provide simply criteria for the selection. Refs and tabs

  9. Research on the improvement of nuclear safety -Development of computing code system for level 3 PSA

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jong Tae; Kim, Dong Ha; Park, Won Seok; Hwang, Mi Jeong [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-07-01

    Among the various research areas of the level 3 PSA, the effect of terrain on the transport of radioactive material was investigated. These results will give a physical insight in the development of a new dispersion model. A wind tunnel experiment with bell shaped hill model was made in order to develop a new dispersion model. And an improved dispersion model was developed based on the concentration distribution data obtained from the wind tunnel experiment. This model will be added as an option to the atmospheric dispersion code. A stand-alone atmospheric code using MS Visual Basic programming language which runs at the Windows environment of a PC was developed. A user can easily select a necessary data file and type input data by clicking menus, and can select calculation options such building wake, plume rise etc., if necessary. And a user can easily understand the meaning of concentration distribution on the map around the plant site as well as output files. Also the methodologies for the estimation of radiation exposure and for the calculation of risks was established. These methodologies will be used for the development of modules for the radiation exposure and risks respectively. These modules will be developed independently and finally will be combined to the atmospheric dispersion code in order to develop a level 3 PSA code. 30 tabs., 56 figs., refs. (Author).

  10. Research on the improvement of nuclear safety -Development of computing code system for level 3 PSA

    International Nuclear Information System (INIS)

    Jeong, Jong Tae; Kim, Dong Ha; Park, Won Seok; Hwang, Mi Jeong

    1995-07-01

    Among the various research areas of the level 3 PSA, the effect of terrain on the transport of radioactive material was investigated. These results will give a physical insight in the development of a new dispersion model. A wind tunnel experiment with bell shaped hill model was made in order to develop a new dispersion model. And an improved dispersion model was developed based on the concentration distribution data obtained from the wind tunnel experiment. This model will be added as an option to the atmospheric dispersion code. A stand-alone atmospheric code using MS Visual Basic programming language which runs at the Windows environment of a PC was developed. A user can easily select a necessary data file and type input data by clicking menus, and can select calculation options such building wake, plume rise etc., if necessary. And a user can easily understand the meaning of concentration distribution on the map around the plant site as well as output files. Also the methodologies for the estimation of radiation exposure and for the calculation of risks was established. These methodologies will be used for the development of modules for the radiation exposure and risks respectively. These modules will be developed independently and finally will be combined to the atmospheric dispersion code in order to develop a level 3 PSA code. 30 tabs., 56 figs., refs. (Author)

  11. Verification of the CONPAS (CONtainment Performance Analysis System) code package

    International Nuclear Information System (INIS)

    Kim, See Darl; Ahn, Kwang Il; Song, Yong Man; Choi, Young; Park, Soo Yong; Kim, Dong Ha; Jin, Young Ho.

    1997-09-01

    CONPAS is a computer code package to integrate the numerical, graphical, and results-oriented aspects of Level 2 probabilistic safety assessment (PSA) for nuclear power plants under a PC window environment automatically. For the integrated analysis of Level 2 PSA, the code utilizes four distinct, but closely related modules: (1) ET Editor, (2) Computer, (3) Text Editor, and (4) Mechanistic Code Plotter. Compared with other existing computer codes for Level 2 PSA, and CONPAS code provides several advanced features: computational aspects including systematic uncertainty analysis, importance analysis, sensitivity analysis and data interpretation, reporting aspects including tabling and graphic as well as user-friendly interface. The computational performance of CONPAS has been verified through a Level 2 PSA to a reference plant. The results of the CONPAS code was compared with an existing level 2 PSA code (NUCAP+) and the comparison proves that CONPAS is appropriate for Level 2 PSA. (author). 9 refs., 8 tabs., 14 figs

  12. Level 2 PSA methodology and severe accident management

    International Nuclear Information System (INIS)

    1997-01-01

    The objective of the work was to review current Level 2-PSA (Probabilistic Safety Assessment) methodologies and practices and to investigate how Level 2-PSA can support severe accident management programmes, i.e. the development, implementation, training and optimisation of accident management strategies and measures. For the most part, the presented material reflects the state in 1996. Current Level 2 PSA results and methodologies are reviewed and evaluated with respect to plant type specific and generic insights. Approaches and practices for using PSA results in the regulatory context and for supporting severe accident management programmes by input from level 2 PSAs are examined. The work is based on information contained in: PSA procedure guides, PSA review guides and regulatory guides for the use of PSA results in risk informed decision making; plant specific PSAs and PSA related literature exemplifying specific procedures, methods, analytical models, relevant input data and important results, use of computer codes and results of code calculations. The PSAs are evaluated with respect to results and insights. In the conclusion section, the present state of risk informed decision making, in particular in the level 2 domain, is described and substantiated by relevant examples

  13. Development of seismic PSA methodology at JAERI

    International Nuclear Information System (INIS)

    Muramatsu, K.; Ebisawa, K.; Matsumoto, K.; Oikawa, T.; Kondo, M.

    1995-01-01

    The Japan Atomic Energy Research Institute (JAERI) is developing a methodology for seismic probabilistic safety assessment (PSA) of nuclear power plants, aiming at providing a set of procedures, computer codes and data suitable for performing seismic PSA in Japan. In order to demonstrate the usefulness of JAERI's methodology and to obtain better understanding on the controlling factors of the results of seismic PSAs, a seismic PSA for a BWR is in progress. In the course of this PSA, various improvements were made on the methodology. In the area of the hazard analysis, the application of the current method to the model plant site is being carried out. In the area of response analysis, the response factor method was modified to consider the non-linear response effect of the building. As for the capacity evaluation of components, since capacity data for PSA in Japan are very scarce, capacities of selected components used in Japan were evaluated. In the systems analysis, the improvement of the SECOM2 code was made to perform importance analysis and sensitivity analysis for the effect of correlation of responses and correlation of capacities. This paper summarizes the recent progress of the seismic PSA research at JAERI with emphasis on the evaluation of component capacity and the methodology improvement of systems reliability analysis. (author)

  14. Development of computing code system for level 3 PSA

    International Nuclear Information System (INIS)

    Jeong, Jong Tae; Yu, Dong Han; Kim, Seung Hwan.

    1997-07-01

    Among the various research areas of the level 3 PSA, the effect of terrain on the transport of radioactive material was investigated through wind tunnel experiment. These results will give a physical insight in the development of a new dispersion model. Because there are some discrepancies between the results from Gaussian plume model and those from field test, the effect of terrain on the atmospheric dispersion was investigated by using CTDMPLUS code. Through this study we find that the model which can treat terrain effect is essential in the atmospheric dispersion of radioactive materials and the CTDMPLUS model can be used as a useful tool. And it is suggested that modification of a model and experimental study should be made through the continuous effort. The health effect assessment near the Yonggwang site by using IPE (Individual plant examination) results and its site data was performed. The health effect assessment is an important part of consequence analysis of a nuclear power plant site. The MACCS was used in the assessment. Based on the calculation of CCDF for each risk measure, it is shown that CCDF has a slow slope and thus wide probability distribution in cases of early fatality, early injury, total early fatality risk, and total weighted early fatality risk. And in cases of cancer fatality and population dose within 48km and 80km, the CCDF curve have a steep slope and thus narrow probability distribution. The establishment of methodologies for necessary models for consequence analysis resulting form a server accident in the nuclear power plant was made and a program for consequence analysis was developed. The models include atmospheric transport and diffusion, calculation of exposure doses for various pathways, and assessment of health effects and associated risks. Finally, the economic impact resulting form an accident in a nuclear power plant was investigated. In this study, estimation models for each cost terms that considered in economic

  15. Development of computing code system for level 3 PSA

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jong Tae; Yu, Dong Han; Kim, Seung Hwan

    1997-07-01

    Among the various research areas of the level 3 PSA, the effect of terrain on the transport of radioactive material was investigated through wind tunnel experiment. These results will give a physical insight in the development of a new dispersion model. Because there are some discrepancies between the results from Gaussian plume model and those from field test, the effect of terrain on the atmospheric dispersion was investigated by using CTDMPLUS code. Through this study we find that the model which can treat terrain effect is essential in the atmospheric dispersion of radioactive materials and the CTDMPLUS model can be used as a useful tool. And it is suggested that modification of a model and experimental study should be made through the continuous effort. The health effect assessment near the Yonggwang site by using IPE (Individual plant examination) results and its site data was performed. The health effect assessment is an important part of consequence analysis of a nuclear power plant site. The MACCS was used in the assessment. Based on the calculation of CCDF for each risk measure, it is shown that CCDF has a slow slope and thus wide probability distribution in cases of early fatality, early injury, total early fatality risk, and total weighted early fatality risk. And in cases of cancer fatality and population dose within 48km and 80km, the CCDF curve have a steep slope and thus narrow probability distribution. The establishment of methodologies for necessary models for consequence analysis resulting form a server accident in the nuclear power plant was made and a program for consequence analysis was developed. The models include atmospheric transport and diffusion, calculation of exposure doses for various pathways, and assessment of health effects and associated risks. Finally, the economic impact resulting form an accident in a nuclear power plant was investigated. In this study, estimation models for each cost terms that considered in economic

  16. User's manual for the G.T.M.-1 computer code

    International Nuclear Information System (INIS)

    Prado-Herrero, P.

    1992-01-01

    This document describes the GTM-1 ( Geosphere Transport Model, release-1) computer code and is intended to provide the reader with enough detailed information in order to use the code. GTM-1 was developed for the assessment of radionuclide migration by the ground water through geologic deposits whose properties can change along the pathway.GTM-1 solves the transport equation by the finite differences method ( Crank-Nicolson scheme ). It was developped for specific use within Probabilistic System Assessment (PSA) Monte Carlo Method codes; in this context the first application of GTM-1 was within the LISA (Long Term Isolation System Assessment) code. GTM-1 is also available as an independent model, which includes various submodels simulating a multi-barrier disposal system. The code has been tested with the PSACOIN ( Probabilistic System Assessment Codes intercomparison) benchmarks exercises from PSAC User Group (OECD/NEA). 10 refs., 6 Annex., 2 tabs

  17. Comparison of global sensitivity analysis techniques and importance measures in PSA

    International Nuclear Information System (INIS)

    Borgonovo, E.; Apostolakis, G.E.; Tarantola, S.; Saltelli, A.

    2003-01-01

    This paper discusses application and results of global sensitivity analysis techniques to probabilistic safety assessment (PSA) models, and their comparison to importance measures. This comparison allows one to understand whether PSA elements that are important to the risk, as revealed by importance measures, are also important contributors to the model uncertainty, as revealed by global sensitivity analysis. We show that, due to epistemic dependence, uncertainty and global sensitivity analysis of PSA models must be performed at the parameter level. A difficulty arises, since standard codes produce the calculations at the basic event level. We discuss both the indirect comparison through importance measures computed for basic events, and the direct comparison performed using the differential importance measure and the Fussell-Vesely importance at the parameter level. Results are discussed for the large LLOCA sequence of the advanced test reactor PSA

  18. PSA kinetics after prostate brachytherapy: PSA bounce phenomenon and its implications for PSA doubling time

    International Nuclear Information System (INIS)

    Ciezki, Jay P.; Reddy, Chandana A.; Garcia, Jorge; Angermeier, Kenneth; Ulchaker, James; Mahadevan, Arul; Chehade, Nabil; Altman, Andrew; Klein, Eric A.

    2006-01-01

    Purpose: To analyze prostate-specific antigen (PSA) kinetics in patients treated with prostate brachytherapy (PI) with a minimum of 5 years of PSA follow-up. Methods and Materials: The records of 162 patients treated with PI for localized prostate cancer with a minimum of 5 years of PSA follow-up were reviewed. A variety of pretreatment and posttreatment variables were examined. Patients were coded as having a PSA bounce if their PSA achieved a nadir, elevated at least 0.2 ng/mL greater than that nadir, and decreased to, or below, the initial nadir. Two definitions of biochemical failure (bF) or biochemical relapse-free survival (bRFS) were used: the classic American Society for Therapeutic Radiology and Oncology consensus definition of three consecutive rises (bF3) and the nadir plus 2 ng/mL definition (bFn+2). Associations between a PSA bounce and the various pre- and posttreatment factors were assessed with logistic regression analysis, and the association between a PSA bounce and bF was examined with the log-rank test. The Mann-Whitney U test was applied to test for differences in the PSA doubling time (PSADT) and the time to a PSA rise between the PSA bounce patients and the bF patients. PSADT was calculated from the nadir to the time of the first PSA rise, because this point is known first in the clinical setting. Results: The 5-year overall bRFS rate was 87% for the bF3 definition and 96% for the bFn+2 definition. A PSA bounce was experienced by 75 patients (46.3%). Patients who experienced a PSA bounce were less likely to have a bF, regardless of the bRFS definition used (bF3: p = 0.0015; bFn+2: p = 0.0040). Among the pre- and posttreatment factors, only younger age predicted for a PSA bounce on multivariate analysis (p = 0.0018). The use of androgen deprivation had no effect on PSA bounce. No difference was found in the PSADT between patients who had a PSA bounce and those with bF. The median PSADT for those with a PSA bounce was 8.3 months vs. 10.3 months

  19. The Uncertainty Test for the MAAP Computer Code

    International Nuclear Information System (INIS)

    Park, S. H.; Song, Y. M.; Park, S. Y.; Ahn, K. I.; Kim, K. R.; Lee, Y. J.

    2008-01-01

    After the Three Mile Island Unit 2 (TMI-2) and Chernobyl accidents, safety issues for a severe accident are treated in various aspects. Major issues in our research part include a level 2 PSA. The difficulty in expanding the level 2 PSA as a risk information activity is the uncertainty. In former days, it attached a weight to improve the quality in a internal accident PSA, but the effort is insufficient for decrease the phenomenon uncertainty in the level 2 PSA. In our country, the uncertainty degree is high in the case of a level 2 PSA model, and it is necessary to secure a model to decrease the uncertainty. We have not yet experienced the uncertainty assessment technology, the assessment system itself depends on advanced nations. In advanced nations, the severe accident simulator is implemented in the hardware level. But in our case, basic function in a software level can be implemented. In these circumstance at home and abroad, similar instances are surveyed such as UQM and MELCOR. Referred to these instances, SAUNA (Severe Accident UNcertainty Analysis) system is being developed in our project to assess and decrease the uncertainty in a level 2 PSA. It selects the MAAP code to analyze the uncertainty in a severe accident

  20. Reactor cooling systems thermal-hydraulic assessment of the ASTEC V1.3 code in support of the French IRSN PSA-2 on the 1300 MWe PWRs

    International Nuclear Information System (INIS)

    Tregoures, Nicolas; Philippot, Marc; Foucher, Laurent; Guillard, Gaetan; Fleurot, Joelle

    2010-01-01

    The French Institut de Radioprotection et de Surete Nucleaire (IRSN) is performing a level 2 Probabilistic Safety Assessment (PSA-2) on the French 1300 MWe PWRs. This PSA-2 study is relying on the ASTEC integral computer code, jointly developed by IRSN and GRS (Germany). In order to assess the reliability and the quality of physical results of the ASTEC V1.3 code as well as the PWR 1300 MWe reference input deck, a wide-ranging series of comparisons with the French best-estimate thermal-hydraulic code CATHARE 2 V2.5 has been performed on 14 different severe-accident scenarios. The present paper details 4 out of the 14 studied scenarios: a 12-in. cold leg Loss of Coolant Accident (LOCA), a 2-tube Steam Generator Tube Rupture (SGTR), a 12-in. Steam Line Break (SLB) and a total Loss of Feed Water scenario (LFW). The thermal-hydraulic behavior of the primary and secondary circuits is thoroughly investigated and compared to the CATAHRE 2 V2.5 results. The ASTEC results of the core degradation phase are also presented. Overall, the thermal-hydraulic behavior given by the ASTEC V1.3 is in very good agreement with the CATHARE 2 V2.5 results.

  1. SHEAT for PC. A computer code for probabilistic seismic hazard analysis for personal computer, user's manual

    International Nuclear Information System (INIS)

    Yamada, Hiroyuki; Tsutsumi, Hideaki; Ebisawa, Katsumi; Suzuki, Masahide

    2002-03-01

    The SHEAT code developed at Japan Atomic Energy Research Institute is for probabilistic seismic hazard analysis which is one of the tasks needed for seismic Probabilistic Safety Assessment (PSA) of a nuclear power plant. At first, SHEAT was developed as the large sized computer version. In addition, a personal computer version was provided to improve operation efficiency and generality of this code in 2001. It is possible to perform the earthquake hazard analysis, display and the print functions with the Graphical User Interface. With the SHEAT for PC code, seismic hazard which is defined as an annual exceedance frequency of occurrence of earthquake ground motions at various levels of intensity at a given site is calculated by the following two steps as is done with the large sized computer. One is the modeling of earthquake generation around a site. Future earthquake generation (locations, magnitudes and frequencies of postulated earthquake) is modeled based on the historical earthquake records, active fault data and expert judgment. Another is the calculation of probabilistic seismic hazard at the site. An earthquake ground motion is calculated for each postulated earthquake using an attenuation model taking into account its standard deviation. Then the seismic hazard at the site is calculated by summing the frequencies of ground motions by all the earthquakes. This document is the user's manual of the SHEAT for PC code. It includes: (1) Outline of the code, which include overall concept, logical process, code structure, data file used and special characteristics of code, (2) Functions of subprogram and analytical models in them, (3) Guidance of input and output data, (4) Sample run result, and (5) Operational manual. (author)

  2. Summary report for the second TUV-workshop proceedings on living PSA application

    International Nuclear Information System (INIS)

    1991-01-01

    This workshop on living PSA Application was organized to support the OECD/NEA CSNI-Principal Working Group No.5 on Risk Assessment for an international exchange of experience on living PSA application. The first session was devoted to Living PSA Applications and the second session to Tools for Living PSA. Living PSA Applications: Reasons for performing PSA (regulatory requirement, targets; corporate requirement, targets; safety related activity prioritization; other); Logistic of Living PSA Management (Corporate management involvement, Decision making levels and guidance, Plant level involvement, Required personnel commitment, Frequency and extent of re-quantification of PSA, Types of safety/risk parameters to be monitored, Quality assurance on maintaining Living PSA); Examples of Application (Experiences of application, State of Living PSA/e.g. all accident sequences involved, Details of component level involvement). Tools for Living PSA: Data Collection Systems and Codes (Source and type of data collected, Probabilistic parameter quantification, Interface to basic event data, Data code systems). An executive summary of the workshop is given

  3. Quality PSA for PSA applications

    International Nuclear Information System (INIS)

    Carska, K.; Rybar, J.

    2012-03-01

    The safety guideline defines with more precision Nuclear Regulatory Authority of the Slovak Republic requirements of the quality of probabilistic safety assessment (PSA) for PSA application. Term of quality of PSA is explained in detail. Procedure for determining the quality of PSA is provided. The categorization of PSA study according the quality of PSA is suggested. A comprehensive list of PSA applications for nuclear facilities is provided. What technical features of a PSA should be satisfied to support the PSA applications of interest is stated. (authors)

  4. Reviewing PSA-based analyses to modify technical specifications at nuclear power plants

    International Nuclear Information System (INIS)

    Samanta, P.K.; Martinez-Guridi, G.; Vesely, W.E.

    1995-12-01

    Changes to Technical Specifications (TSs) at nuclear power plants (NPPs) require review and approval by the United States Nuclear Regulatory Commission (USNRC). Currently, many requests for changes to TSs use analyses that are based on a plant's probabilistic safety assessment (PSA). This report presents an approach to reviewing such PSA-based submittals for changes to TSs. We discuss the basic objectives of reviewing a PSA-based submittal to modify NPP TSs; the methodology of reviewing a TS submittal, and the differing roles of a PSA review, a PSA Computer Code review, and a review of a TS submittal. To illustrate this approach, we discuss our review of changes to allowed outage time (AOT) and surveillance test interval (STI) in the TS for the South Texas Project Nuclear Generating Station. Based on this experience gained, a check-list of items is given for future reviewers; it can be used to verify that the submittal contains sufficient information, and also that the review has addressed the relevant issues. Finally, recommended steps in the review process and the expected findings of each step are discussed

  5. Development of level 2 PSA technology

    International Nuclear Information System (INIS)

    Kim, Dong Ha; Park, Soo Yong; Kim, See Darl; Song, Yong Mann; Ahn, Kwang Il; Park, Jae Wu; Jin, Young Ho.

    1997-07-01

    The objective of this project is the development of the computer code system for level 2 probabilistic safety assessment (PSA) of nuclear power plants. The scope of the project can be divided into three areas. The first area is to develop the computer code (CONPAS) which can quantify the accident progression event trees. CONPAS beta version has been developed this year and it is comprised of four modules : 1) EDITOR for generating the event tree logic diagrams and 1) COMPUTER for event tree quantification and for additional use of the calculated results. 3) TEXT EDITOR and 4) CODE PLOTTER. Comparing with the existing computer code, the present code provides a flexible code reusability and user interface, convenient edition of logic diagram, data operation, and systematic quantification of the results. The methodology development of containment structural analysis is the second area. The specific tasks included the collection and analysis of the containment failure modes for the various containment types, and the methodology establishment for the containment structure analysis. Over twenty large dry PWR containments, the database for containment failure mode and pressure has been constructed and the simplified fragility model has been proposed to calculate the containment failure probability. They will be used as an important input not only in the containment analysis but also in the source term analysis. For the last, source term analyzing methodology and its applied computer code that is named as 'KORSOR' are developed. KORSOR which used parametric model approach combined modules which consist of accident sequence input module via user's logic rule, random sample generating module, parametric database module, and source term uncertainty quantification module. The characteristics of parametric data which use din the source term analyzing model is analyzed and the constructing idea and example for the parametric database is suggested. (author). 67 refs., 66 tabs

  6. Development of a simple computer code to obtain relevant data on H2 and CO combustion in severe accidents and to aid in PSA-2 assessments

    International Nuclear Information System (INIS)

    Robledo, F.; Martin-Valdepenas, J.M.; Jimenez, M.A.; Martin-Fuertes, F.

    2007-01-01

    By following Consejo de Seguridad Nuclear (CSN) requirements, all of the Spanish NPPs performed plant specific PSA level 2 studies and implemented Severe Accident Management Guidelines during the first years of this century. CSN and contractors made an independent detailed review of these PSA level 2 studies. This independent review included the performance of plant specific calculations by using the MELCOR code and some other stand-alone codes and the calculation of the fission product release frequencies for each plant. One of the aspects treated in detail by CSN evaluations was the calculation of the containment failure probability due to the burn of combustible gases generated during a severe accident. It was shown that it would be useful to have a fast running code with capability to provide the most relevant data concerning H 2 and CO combustion. Therefore, the Polytechnic University of Madrid (UPM) developed the CPPC code for the CSN. This stand-alone module makes fast calculations on maximum static pressures in the containment building generated from H 2 and CO combustion in severe accidents, considering well-mixed atmospheres and includes the most recent advances and developments in the field of H 2 and CO combustion. Code input is simple: mass of H 2 and CO, initial environmental conditions inside the containment before the combustion and simple geometric data, such as the volume of the building enclosing the combustible gases. The code calculates the containment temperature assuming steam saturated atmosphere and provides the following output: - Combustion completeness (CC); - Adiabatic and isochoric combustion pressure (p AICC ); - Chapman-Jouguet pressure (p CJ ); - Chapman-Jouguet reflected pressure (p Cjrefl ). When the combustion regime results in dynamic pressure loads, the CPPC code calculates the equivalent static pressure (effective pressure p eff ) by modeling the containment structure as a simple harmonic oscillator. Additionally, the code

  7. Comparative evaluation of PSA-Density, percent free PSA and total PSA

    OpenAIRE

    Ströbel, Greta

    2010-01-01

    BACKGROUND The objective of this study was to evaluate the prostate specific antigen (PSA) density (PSAD) (the quotient of PSA and prostate volume) compared with the percent free PSA (%fPSA) and total PSA (tPSA) in different total PSA (tPSA) ranges from 2 ng/mL to 20 ng/mL. Possible cut-off levels depending on the tPSA should be established. METHODS In total, 1809 men with no pretreatment of the prostate were enrolled between 1996 and 2004. Total and free PSA were measured with t...

  8. The open PSA standard as a framework for migration of probabilistic models. Experiences with the KKB PSA

    International Nuclear Information System (INIS)

    Becker, G.; Hussels, U.; Epstein, S.; Rauzy, A.; Schubert, B.

    2008-01-01

    In its present state, the open PSA standard is helpful to determine capabilities of PSA approaches, which have been taken into account by those who formulated it. As soon, as tools come up, which can automatically bring a given PSA into the standard form, the data will be accessible by other software tools, which either are supplementary to the original one, or they may act in the context of quality control. Taking into account, that a PSA model represents a value of some two to ten person years (dependent on level of completeness and level of detail), it is important to have the data in a transparent way, which does not depend on proprietary formats, and can thus be used for more purposes than those, which are implemented in given PSA codes. (orig.)

  9. SERIAL PERCENT-FREE PSA IN COMBINATION WITH PSA FOR POPULATION-BASED EARLY DETECTION OF PROSTATE CANCER

    Science.gov (United States)

    Ankerst, Donna Pauler; Gelfond, Jonathan; Goros, Martin; Herrera, Jesus; Strobl, Andreas; Thompson, Ian M.; Hernandez, Javier; Leach, Robin J.

    2016-01-01

    PURPOSE To characterize the diagnostic properties of serial percent-free prostate-specific antigen (PSA) in relation to PSA in a multi-ethnic, multi-racial cohort of healthy men. MATERIALS AND METHODS 6,982 percent-free PSA and PSA measures were obtained from participants in a 12 year+ Texas screening study comprising 1625 men who never underwent biopsy, 497 who underwent one or more biopsies negative for prostate cancer, and 61 diagnosed with prostate cancer. Area underneath the receiver-operating-characteristic-curve (AUC) for percent-free PSA, and the proportion of patients with fluctuating values across multiple visits were determined according to two thresholds (under 15% versus 25%) were evaluated. The proportion of cancer cases where percent-free PSA indicated a positive test before PSA > 4 ng/mL did and the number of negative biopsies that would have been spared by percent-free PSA testing negative were computed. RESULTS Percent-free PSA fluctuated around its threshold of PSA tested positive earlier than PSA in 71.4% (34.2%) of cancer cases, and among men with multiple negative biopsies and a PSA > 4 ng/mL, percent-free PSA would have tested negative in 31.6% (65.8%) instances. CONCLUSIONS Percent-free PSA should accompany PSA testing in order to potentially spare unnecessary biopsies or detect cancer earlier. When near the threshold, both tests should be repeated due to commonly observed fluctuation. PMID:26979652

  10. Application of the integral code MELCOR for German NPPs and use within accident management and PSA projects

    International Nuclear Information System (INIS)

    Sonnenkalb, Martin

    2006-01-01

    The paper summarizes the application of MELCOR to German NPPS with PWR and BWR. A development of different code systems like ATHLET/ATHLET-CD, COCOSYS and ASTEC is done as well at GRS but it is not discussed in this paper. GRS has been using MELCOR since 1990 for real plant calculations. The results of MELCOR analyses are used mainly in PSA level 2 studies and in Accident Management projects for both types of NPPs. MELCOR has been a very useful and robust tool for these analyses. The calculations performed within the PSA level 2 studies for both types of German NPPs have shown that typical severe accident scenarios are characterized by several phases and that the consideration of plant specifics are important not only for realistic source term calculations. An overview of typically severe accident phases together with main accident management measures installed in German NPPs is presented in the paper. Several severe accident sequences have been calculated for both reactor types and some detailed nodalisation studies and code to code comparisons have been prepared in the past, to prove the developed core, reactor circuit and containment/building nodalisation schemes. Together with the compilation of the MELCOR data set, the qualification of the nodalisation schemes has been pursued with comparative calculations with detailed GRS codes for selected phases of severe accidents. The results of these comparative analyses showed in most of the areas a good agreement of essential parameters and of the general description of the plant behaviour during the accident progression. The in general detail of the German plant nodalisation schemes developed for MELCOR contributes significantly to this good agreement between integral and detailed code results. The implementation of MELCOR into the GRS simulator ATLAS was very important for the assessment of the results, not only due to the great detail of the nodalisation schemes used. It is used for training of severe accident

  11. Recent Developments in Level 2 PSA and Severe Accident Management

    International Nuclear Information System (INIS)

    Ang, Ming Leang; Shepherd, Charles; Gauntt, Randall; Landgren, Vickie; Van Dorsselaere, Jean Pierre; Chaumont, Bernard; Raimond, Emmanuel; Magallon, Daniel; Prior, Robert; Mlady, Ondrej; Khatib-Rahbar, Mohsen; Lajtha, Gabor; Tinkler, Charles; Siu, Nathan

    2007-01-01

    In 1997, CSNI WGRISK produced a report on the state of the art in Level 2 PSA and severe accident management - NEA/CSNI/R(1997)11. Since then, there have been significant developments in that more Level 2 PSAs have been carried out worldwide for a variety of nuclear power plant designs including some that were not addressed in the original report. In addition, there is now a better understanding of the severe accident phenomena that can occur following core damage and the way that they should be modelled in the PSA. As requested by CSNI in December 2005, the objective of this study was to produce a report that updates the original report and gives an account of the developments that have taken place since 1997. The aim has been to capture the most significant new developments that have occurred rather than to provide a full update of the original report, most of which is still valid. This report is organised using the same structure as the original report as follows: Chapter 2: Summary on state of application, results and insights from recent Level 2 PSAs. Chapter 3: Discussion on key severe accident phenomena and modelling issues, identification of severe accident issues that should be treated in Level 2 PSAs for accident management applications, review of severe accident computer codes and the use of these codes in Level 2 PSAs. Chapter 4: Review of approaches and practices for accident management and SAM, evaluation of actions in Level 2 PSAs. Chapter 5: Review of available Level 2 PSA methodologies, including accident progression event tree / containment event tree development. Chapter 6: Aspects important to quantification, including the use of expert judgement and treatment of uncertainties. Chapter 7: Examples of the use of the results and insights from the Level 2 PSA in the context of an integrated (risk informed) decision making process

  12. Improving PSA quality of KSNP PSA model

    International Nuclear Information System (INIS)

    Yang, Joon Eon; Ha, Jae Joo

    2004-01-01

    In the RIR (Risk-informed Regulation), PSA (Probabilistic Safety Assessment) plays a major role because it provides overall risk insights for the regulatory body and utility. Therefore, the scope, the level of details and the technical adequacy of PSA, i.e. the quality of PSA is to be ensured for the successful RIR. To improve the quality of Korean PSA, we evaluate the quality of the KSNP (Korean Standard Nuclear Power Plant) internal full-power PSA model based on the 'ASME PRA Standard' and the 'NEI PRA Peer Review Process Guidance.' As a working group, PSA experts of the regulatory body and industry also participated in the evaluation process. It is finally judged that the overall quality of the KSNP PSA is between the ASME Standard Capability Category I and II. We also derive some items to be improved for upgrading the quality of the PSA up to the ASME Standard Capability Category II. In this paper, we show the result of quality evaluation, and the activities to improve the quality of the KSNP PSA model

  13. PSA, PSA derivatives, proPSA and prostate health index in the diagnosis of prostate cancer

    OpenAIRE

    Ayyıldız, Sema Nur; Ayyıldız, Ali

    2014-01-01

    Currently, prostate- specific antigen (PSA) is the most common oncological marker used for prostate cancer screening. However, high levels of PSA in benign prostatic hyperplasia and prostatitis decrease the specificity of PSA as a cancer marker. To increase the specificity of PSA, PSA derivatives and PSA kinetics have been used. However, these new techniques were not able to increase the diagnostic specificity for prostate cancer. Therefore, the search for new molecules and derivatives of PSA...

  14. Involvement of Union Fenosa skills in the thermohydraulic area of the Jose Cabrera NPP PSA. Applications of the RELAPS5/MOD2 Code

    International Nuclear Information System (INIS)

    Martin, L.; Saenz Tejada, P.

    1993-01-01

    When performing a level 1 Probabilistic Safety Analysis (PSA) on a standard power plant, in order to model plant response to the potential occurrence of the various initiating events postulated in a PSA, reference documentation applicable to the type of plant in question is frequently consulted. Because of the specific design characteristics of the Jose Cabrera NPP, most of the reference documentation for the W-PWR-type power plants is not applicable to this plant. To fill in these gaps in the documentation and to construct the most realistic model of plant behaviour possible, assistance was sought from Union Fenosa by way of infrastructure, capabilities and thermohydraulic experience of the Nuclear Engineering and Fuel Group, and especially the use of calculations performed with the RELAP5/ MOD2 code. This paper will provide an overview of the general assistance rendered to the PSA by the technical experts in thermohydraulics, the calculations performed with RELAP5/MOD2 and the influence all of this has had on the development, quality and results of the Jose Cabrera NPP level 1 PSA Project. (author)

  15. One Approach to the Fire PSA Uncertainty Analysis

    International Nuclear Information System (INIS)

    Simic, Z.; Mikulicic, V.; Vukovic, I.

    2002-01-01

    Experienced practical events and findings from the number of fire probabilistic safety assessment (PSA) studies show that fire has high relative importance for nuclear power plant safety. Fire PSA is a very challenging phenomenon and a number of issues are still in the area of research and development. This has a major impact on the conservatism of fire PSA findings. One way to reduce the level of conservatism is to conduct uncertainty analysis. At the top-level, uncertainty of the fire PSA can be separated in to three segments. The first segment is related to fire initiating events frequencies. The second uncertainty segment is connected to the uncertainty of fire damage. Finally, there is uncertainty related to the PSA model, which propagates this fire-initiated damage to the core damage or other analyzed risk. This paper discusses all three segments of uncertainty. Some recent experience with fire PSA study uncertainty analysis, usage of fire analysis code COMPBRN IIIe, and uncertainty evaluation importance to the final result is presented.(author)

  16. Comparative Study on Atmospheric Dispersion Module of Level 3 PSA

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Dahye; Jang, Misuk; Kang, Hyun Sik; Kim, Seoung Rae [NESS, Daejeon (Korea, Republic of)

    2016-10-15

    Some regulation documents such as Regulatory Guides and NUREG publications from the U.S. Nuclear Regulatory Commission (NRC) have influences on domestic radiation environmental analyses. As renewal versions of NUREG-0800 and NUREG-1555 have issued lately, the assessment for Severe Accident (SA) with Probabilistic Safety Assessment (PSA) should be added to Safety Analysis Report (SAR) and Radiation Environmental Report (RER). Because these reports are the required documents for obtaining the construction permit and operating license, it is important to understand the PSA methodology and it needs to improve the site-specific input data of L3PSA codes for SA. First, our review focuses on the atmospheric dispersion and deposition related input data of L3PSA code in this paper. Then we will continue to review the improvements of other input data. Two atmospheric dispersion models, which are PAVAN developed for design basis accident and ATMOS of MACCS2 code developed for SA, were reviewed in this paper. L3PSA deals with the effects of severe accidents and basically includes the evaluation of both short- and long-term effects. Therefore, both the deposition effects and nuclide information(type, amount, and chemical characteristics of released radionuclide) would be considered as the input parameters of atmospheric dispersion model for L3PSA. Additionally, the meteorological data would be sampled randomly to meet the purpose of probabilistic method. However, the sampling method would be selected according to analysis purpose. After review, ATMOS module and its input data are suitably developed for the atmospheric dispersion analysis of L3PSA. However, ATMOS module was developed using the site-specific terrain and environment characteristics. For the domestic application, it needs to study the input data reflecting the Korean terrain and environment characteristics. It would be also continuously improved in response to the time- and site-specific changes of weather

  17. Level 1 and 2 PSA methodology taking into account new design, operating and safety factors. Rev. 1

    International Nuclear Information System (INIS)

    Jirsa, P.; Patrik, M.

    2000-11-01

    The status of probabilistic safety assessment (PSA) is discussed (i) in relation to the expected nature of 'revolutionary' innovations and (ii) in the light of the EUR document, summarizing requirements put by European NPP operators on the future NPP design. The aims included: (1) analysis of limitations to the current PSA methodology; (2) specification of physical and operation processes the knowledge of which is necessary to ensure the safety criteria of advanced reactors; (3) summarisation of existing knowledge and description formats of the processes; (4) identification of theoretical and experimental work required to address the problem, preparation of data and computer codes, ensuring traceability to EU developmental programs. (P.A.)

  18. Establishment of Infrastructure for Domestic-Specific Level 3 PSA based on MACCS2

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Seung-Cheol; Han, Seok-Jung; Choi, Sun-Yeong; Lee, Seung-Jun [KAERI, Daejeon (Korea, Republic of); Kim, Wan-Seob [Korea Reliability Technology and System, Daejeon (Korea, Republic of)

    2015-05-15

    Research activities related to the Level 3 PSA have naturally disappeared since the use of risk surrogates. Recently, Level 3 PSA was only performed to the extent of the purpose of operating license for the plant under construction. Since the Fukushima accident, concern about a comprehensive site-specific Level 3 PSA has been raised for some compelling reasons, especially the evaluation of the domestic multi-unit site risk effect including other site radiological sources (e.g., spent fuel pool, multi-units). Unfortunately, there are no domestic-specific consequence analysis code and input database required to perform a site-specific Level 3 PSA. The paper focuses on the development of the input data management system for domestic-specific Level 3 PSA based MACCS2 (MELCOR Accident Consequence Code System). The authors call it KOSCA-MACCS2 (Korea Off-Site Consequence Analysis based in MACCS2). It serves as an integrated platform for a domestic-specific Level 3 PSA. Also, it provides the pre-processing modules to automatically generate MACCS2 input from diverse types of the domestic-specific data including numerical map data, e.g., meteorological data, numerical population map, digital land use map, economic statistics and so on. Note that some functions should be still developed and added on it, e.g., post-processing module to convert MACCS2 outputs to graphic report forms, and so on. Henceforth, it is necessary to develop a Korean-specific Level 3 PSA code as a substitution for the foreign software, MACCS2.

  19. Improvement of Severe Accident Analysis Computer Code and Development of Accident Management Guidance for Heavy Water Reactor

    International Nuclear Information System (INIS)

    Park, Soo Yong; Kim, Ko Ryu; Kim, Dong Ha; Kim, See Darl; Song, Yong Mann; Choi, Young; Jin, Young Ho

    2005-03-01

    The objective of the project is to develop a generic severe accident management guidance(SAMG) applicable to Korean PHWR and the objective of this 3 year continued phase is to construct a base of the generic SAMG. Another objective is to improve a domestic computer code, ISAAC (Integrated Severe Accident Analysis code for CANDU), which still has many deficiencies to be improved in order to apply for the SAMG development. The scope and contents performed in this Phase-2 are as follows: The characteristics of major design and operation for the domestic Wolsong NPP are analyzed from the severe accident aspects. On the basis, preliminary strategies for SAM of PHWR are selected. The information needed for SAM and the methods to get that information are analyzed. Both the individual strategies applicable for accident mitigation under PHWR severe accident conditions and the technical background for those strategies are developed. A new version of ISAAC 2.0 has been developed after analyzing and modifying the existing models of ISAAC 1.0. The general SAMG applicable for PHWRs confirms severe accident management techniques for emergencies, provides the base technique to develop the plant specific SAMG by utility company and finally contributes to the public safety enhancement as a NPP safety assuring step. The ISAAC code will be used inevitably for the PSA, living PSA, severe accident analysis, SAM program development and operator training in PHWR

  20. Improvement of Severe Accident Analysis Computer Code and Development of Accident Management Guidance for Heavy Water Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Park, Soo Yong; Kim, Ko Ryu; Kim, Dong Ha; Kim, See Darl; Song, Yong Mann; Choi, Young; Jin, Young Ho

    2005-03-15

    The objective of the project is to develop a generic severe accident management guidance(SAMG) applicable to Korean PHWR and the objective of this 3 year continued phase is to construct a base of the generic SAMG. Another objective is to improve a domestic computer code, ISAAC (Integrated Severe Accident Analysis code for CANDU), which still has many deficiencies to be improved in order to apply for the SAMG development. The scope and contents performed in this Phase-2 are as follows: The characteristics of major design and operation for the domestic Wolsong NPP are analyzed from the severe accident aspects. On the basis, preliminary strategies for SAM of PHWR are selected. The information needed for SAM and the methods to get that information are analyzed. Both the individual strategies applicable for accident mitigation under PHWR severe accident conditions and the technical background for those strategies are developed. A new version of ISAAC 2.0 has been developed after analyzing and modifying the existing models of ISAAC 1.0. The general SAMG applicable for PHWRs confirms severe accident management techniques for emergencies, provides the base technique to develop the plant specific SAMG by utility company and finally contributes to the public safety enhancement as a NPP safety assuring step. The ISAAC code will be used inevitably for the PSA, living PSA, severe accident analysis, SAM program development and operator training in PHWR.

  1. Extreme conservation of the psaA/psaB intercistronic spacer reveals a translational motif coincident with the evolution of land plants.

    Science.gov (United States)

    Peredo, Elena L; Les, Donald H; King, Ursula M; Benoit, Lori K

    2012-12-01

    Although chloroplast transcriptional and translational mechanisms were derived originally from prokaryote endosymbionts, chloroplasts retain comparatively few genes as a consequence of the overall transfer to the nucleus of functions associated formerly with prokaryotic genomes. Various modifications reflect other evolutionary shifts toward eukaryotic regulation such as posttranscriptional transcript cleavage with individually processed cistrons in operons and gene expression regulated by nuclear-encoded sigma factors. We report a notable exception for the psaA-psaB-rps14 operon of land plant (embryophyte) chloroplasts, where the first two cistrons are separated by a spacer region to which no significant role had been attributed. We infer an important function of this region, as indicated by the conservation of identical, structurally significant sequences across embryophytes and their ancestral protist lineages, which diverged some 0.5 billion years ago. The psaA/psaB spacers of embryophytes and their progenitors exhibit few sequence and length variants, with most modeled transcripts resolving the same secondary structure: a loop with projecting Shine-Dalgarno site and well-defined stem that interacts with adjacent coding regions to sequester the psaB start codon. Although many functions of the original endosymbiont have been usurped by nuclear genes or interactions, conserved functional elements of embryophyte psaA/psaB spacers provide compelling evidence that translation of psaB is regulated here by a cis-acting mechanism comparable to those common in prokaryotes. Modeled transcripts also indicate that spacer variants in some plants (e.g., aquatic genus Najas) potentially reflect ecological adaptations to facilitate temperature-regulated translation of psaB.

  2. PSA Review Handbook

    International Nuclear Information System (INIS)

    Hallman, Anders; Nyman, Ralph; Knochenhauer, Michael

    2004-05-01

    The Swedish Nuclear Power Inspectorate (SKI) expresses requirements on the performance of PSAs as well as on PSA activities in general in the the regulatory document 'Regulations Concerning Safety in Certain Nuclear Facilities', SKlFS 1998:1. The follow-up of these activities is part of the inspection tasks of the SKI. In view or this, there is a need for documented guidelines on now to perform these inspections and reviews. The SKI PSA Review Handbook is intended to be a support in the SKI inspection and control of the PSA activities or the licensees. These PSA activities include both the organisation and working procedures of the licensee, the layout and contents of the PSA, and its areas of application. Using the regulation SKIFS 1998:1 as a starting point, the review handbook presents important aspects to be considered when judging whether a licensee fulfils the requirements on PSA activities, including the performance of PSA:s or PSA applications. The handbook shall also be a guidance for the review of PSA:s. However, the intention of the PSA Review Handbook is not to be a handbook for how a PSA is performed. The PSA Review Handbook is applicable to all types or initiating events and all operating conditions, and has been structured in a way, which stresses the integrated characteristics of PSA in the creation of the risk picture of a plant. The PSA Review Handbook has been based on the requirements for PSA of nuclear power plants, as this is the most extensive application. However, the relevant parts of it are also applicable when analysing other nuclear installations. The PSA Review Handbook is published as a research report as its contents are judged to be of general interest, and the SKI welcomes comments to the handbook. An update or the PSA Review Handbook may be required as experience with the use of the handbook is acquired and if general PSA requirements change

  3. Short overview of PSA quantification methods, pitfalls on the road from approximate to exact results

    International Nuclear Information System (INIS)

    Banov, Reni; Simic, Zdenko; Sterc, Davor

    2014-01-01

    Over time the Probabilistic Safety Assessment (PSA) models have become an invaluable companion in the identification and understanding of key nuclear power plant (NPP) vulnerabilities. PSA is an effective tool for this purpose as it assists plant management to target resources where the largest benefit for plant safety can be obtained. PSA has quickly become an established technique to numerically quantify risk measures in nuclear power plants. As complexity of PSA models increases, the computational approaches become more or less feasible. The various computational approaches can be basically classified in two major groups: approximate and exact (BDD based) methods. In recent time modern commercially available PSA tools started to provide both methods for PSA model quantification. Besides availability of both methods in proven PSA tools the usage must still be taken carefully since there are many pitfalls which can drive to wrong conclusions and prevent efficient usage of PSA tool. For example, typical pitfalls involve the usage of higher precision approximation methods and getting a less precise result, or mixing minimal cuts and prime implicants in the exact computation method. The exact methods are sensitive to selected computational paths in which case a simple human assisted rearrangement may help and even switch from computationally non-feasible to feasible methods. Further improvements to exact method are possible and desirable which opens space for a new research. In this paper we will show how these pitfalls may be detected and how carefully actions must be done especially when working with large PSA models. (authors)

  4. Experience from the comparison of two PSA-studies

    International Nuclear Information System (INIS)

    Holmberg, J.; Pulkkinen, U.

    2001-03-01

    Two probabilistic safety assessments (PSA) made for nearly identical reactors units (Forsmark 3 and Oskarshamn 3) have been compared. Two different analysis teams made the PSAs, and the analyses became quite different. The goal of the study is to identify, clarify and explain differences between PSA-studies. The purpose is to understand limitations and uncertainties in PSA, to explain reasons for differences between PSA-studies, and to give recommendations for comparison of PSA-studies and for improving the PSA-methodology. The reviews have been made by reading PSA-documentation, using the computer model and interviewing persons involved in the projects. The method and findings have been discussed within the project group. Both the PSA-project and various parts in the PSA-model have been reviewed. A major finding was that the two projects had different purpose and thus had different resources, scope and even methods in their study. The study shows that comparison of PSA results from different plants is normally not meaningful. It takes a very deep knowledge of the PSA studies to make a comparison of the results and usually one has to ensure that the compared studies have the same scope and are based on the same analysis methods. Harmonisation of the PSA-methodology is recommended in the presentation of results, presentation of methods, scope main limitation and assumption, and definitions for end states, initiating events and common cause failures. This would facilitate the comparison of the studies. Methods for validation of PSA for different application areas should be developed. The developed PSA review standards can be applied for a general validation of a study. The most important way to evaluate the real feasibility of PSA can take place only with practical applications. The PSA-documentation and models can be developed to facilitate the communication between PSA-experts and users. In any application consultation with the PSA-expert is however needed. Many

  5. Opium consumption is negatively associated with serum prostate-specific antigen (PSA), free PSA, and percentage of free PSA levels.

    Science.gov (United States)

    Safarinejad, Mohammad Reza; Asgari, Seyyed Alaeddin; Farshi, Alireza; Iravani, Shahrokh; Khoshdel, Alireza; Shekarchi, Babak

    2013-01-01

    Addiction to opium continues to be a major worldwide medical and social problem. The study addressing the association between opium consumption and serum prostate-specific antigen (PSA) level is lacking. We determined the effects of opium consumption on serum PSA levels in opium-addict men. Our study subjects comprised 438 opium-addict men with a mean age of 52.2 ± 6.4 years (group 1). We compared these men with 446 men who did not indicate current or past opium use (group 2). Serum total PSA (tPSA), free PSA (fPSA), % fPSA, and sex hormones were compared between the 2 groups. The mean serum tPSA level was significantly lower in group 1 (1.05 ng/mL) than in controls (1.45 ng/mL) (P = 0.001). Opium consumption was also associated with lower fPSA (P = 0.001) and % fPSA (P = 0.001). Serum free testosterone level in opium-addict patients (132.5 ± 42 pg/mL) was significantly lower than that in controls (156.2 ± 43 pg/mL) (P = 0.03). However, no significant correlation existed between tPSA and free testosterone levels (r = 0.28, 95% CI, -0.036 to 0.51, P = 0.34). Among the patients with cancer in group 1, 35% were found to have high-grade tumor (Gleason score ≥ 7) compared with 26.7% in group 2 (P = 0.02). Total PSA and fPSA were strongly correlated with duration of opium use (r = -0.06, 95% CI, -0.04 to -0.08, P = 0.0001; and r = -0.05, 95% CI, -0.03 to -0.07, P = 0.0001, respectively). Opium consumption is independently and negatively associated with serum tPSA, fPSA, and % fPSA levels.

  6. Incorporating Level-2 PSA Feature of CONPAS into AIMS-PSA Software

    International Nuclear Information System (INIS)

    Han, Sang Hoon; Lim, Hogon; Ahn, Kwang Il

    2014-01-01

    CONPAS (CONtainment Performance Analysis System) utilizes a methodology to treat containment phenomena in detail like APET but in simple way. In mid 2000's, KAERI has developed very fast cut set generator FTREX and PC's OS (Operating system) has changed into Windows 95. Thus, KAERI has developed new Level-1 PSA software, called AIMS-PSA (Advanced Information Management System for PSA) to replace KIRAP. Recently, KAERI has been developing an integrated PSA platform, called OCEANS (On-line Consolidator and Evaluator of All mode risk for Nuclear System), for the risk assessment of all power modes and all hazards. CONPAS for Level-2 PSA was developed in 1990's using the Visual Basic 6.0 compiler which is not supported any more. It needs to be updated for the integrated PSA software framework. This paper describes a study to incorporate the features of CONPAS into AIMS-PSA. The basic idea is to follow the approach of CONPAS, but in the integrated way. Various approaches for Level-2 PSA have been used since WASH-1400. APET approach of NUREG-1150 study would be most comprehensive and complex methodology for containment event tree analysis. CONPAS is the Level-2 PSA software to utilize an approach to treat containment phenomena in detail like APET but in simple way. But, new Level-2 PSA software is required to develop more integrated PSA framework. A modified approach of CONPAS is developed and incorporated in AIMS-PSA software that can handle Level-1 and Level-2 PSA in the integrated way (from the viewpoint of event tree and fault tree). AIMS-PSA combines whole Level-2 PSA model to produce a One Top fault tree and to generate cut sets in the same way as Level-1 PSA. Quantification results of Level-2 PSA such as frequency for each STC can be calculated from the minimal cut sets

  7. Quantum computation with Turaev-Viro codes

    International Nuclear Information System (INIS)

    Koenig, Robert; Kuperberg, Greg; Reichardt, Ben W.

    2010-01-01

    For a 3-manifold with triangulated boundary, the Turaev-Viro topological invariant can be interpreted as a quantum error-correcting code. The code has local stabilizers, identified by Levin and Wen, on a qudit lattice. Kitaev's toric code arises as a special case. The toric code corresponds to an abelian anyon model, and therefore requires out-of-code operations to obtain universal quantum computation. In contrast, for many categories, such as the Fibonacci category, the Turaev-Viro code realizes a non-abelian anyon model. A universal set of fault-tolerant operations can be implemented by deforming the code with local gates, in order to implement anyon braiding. We identify the anyons in the code space, and present schemes for initialization, computation and measurement. This provides a family of constructions for fault-tolerant quantum computation that are closely related to topological quantum computation, but for which the fault tolerance is implemented in software rather than coming from a physical medium.

  8. Summary report of seismic PSA of BWR model plant

    International Nuclear Information System (INIS)

    1999-05-01

    This report presents a seismic PSA (Probabilistic Safety Assessment) methodology developed at the Japan Atomic Energy Research Institute (JAERI) for evaluating risks of nuclear power plants (NPPs) and the results from an application of the methodology to a BWR plant in Japan, which is termed Model Plant'. The seismic PSA procedures developed at JAERI are to evaluate core damage frequency (CDF) and have the following four steps: (1) evaluation of seismic hazard, (2) evaluation of realistic response, (3) evaluation of component capacities and failure probabilities, and (4) evaluation of conditional probability of system failure and CDF. Although these procedures are based on the methodologies established and used in the United States, they include several unique features: (1) seismic hazard analysis is performed with use of available knowledge and database on seismological conditions in Japan; (2) response evaluation is performed with a response factor method which is cost effective and associated uncertainties can be reduced with use of modern methods of design calculations; (3) capacity evaluation is performed with use of test results available in Japan in combination with design information and generic capacity data in the U.S.A.; (4) systems reliability analysis, performed with use of the computer code SECOM-2 developed at JAERI, includes identification of dominant accident sequences, importance analysis of components and systems as well as the CDF evaluation with consideration of the effect of correlation of failures by a newly developed method based on the Monte Carlo method. The effect of correlation has been recognized as an important issue in seismic PSAs. The procedures was used to perform a seismic PSA of a 1100 MWe BWR plant. Results are shown as well as the insights derived and future research needs identified in this seismic PSA. (J.P.N.)

  9. Geochemical computer codes. A review

    International Nuclear Information System (INIS)

    Andersson, K.

    1987-01-01

    In this report a review of available codes is performed and some code intercomparisons are also discussed. The number of codes treating natural waters (groundwater, lake water, sea water) is large. Most geochemical computer codes treat equilibrium conditions, although some codes with kinetic capability are available. A geochemical equilibrium model consists of a computer code, solving a set of equations by some numerical method and a data base, consisting of thermodynamic data required for the calculations. There are some codes which treat coupled geochemical and transport modeling. Some of these codes solve the equilibrium and transport equations simultaneously while other solve the equations separately from each other. The coupled codes require a large computer capacity and have thus as yet limited use. Three code intercomparisons have been found in literature. It may be concluded that there are many codes available for geochemical calculations but most of them require a user that us quite familiar with the code. The user also has to know the geochemical system in order to judge the reliability of the results. A high quality data base is necessary to obtain a reliable result. The best results may be expected for the major species of natural waters. For more complicated problems, including trace elements, precipitation/dissolution, adsorption, etc., the results seem to be less reliable. (With 44 refs.) (author)

  10. Survey of Dynamic PSA Methodologies

    International Nuclear Information System (INIS)

    Lee, Hansul; Kim, Hyeonmin; Heo, Gyunyoung; Kim, Taewan

    2015-01-01

    Event Tree(ET)/Fault Tree(FT) are significant methodology in Probabilistic Safety Assessment(PSA) for Nuclear Power Plants(NPPs). ET/FT methodology has the advantage for users to be able to easily learn and model. It enables better communication between engineers engaged in the same field. However, conventional methodologies are difficult to cope with the dynamic behavior (e.g. operation mode changes or sequence-dependent failure) and integrated situation of mechanical failure and human errors. Meanwhile, new possibilities are coming for the improved PSA by virtue of the dramatic development on digital hardware, software, information technology, and data analysis.. More specifically, the computing environment has been greatly improved with being compared to the past, so we are able to conduct risk analysis with the large amount of data actually available. One method which can take the technological advantages aforementioned should be the dynamic PSA such that conventional ET/FT can have time- and condition-dependent behaviors in accident scenarios. In this paper, we investigated the various enabling techniques for the dynamic PSA. Even though its history and academic achievement was great, it seems less interesting from industrial and regulatory viewpoint. Authors expect this can contribute to better understanding of dynamic PSA in terms of algorithm, practice, and applicability. In paper, the overview for the dynamic PSA was conducted. Most of methodologies share similar concepts. Among them, DDET seems a backbone for most of methodologies since it can be applied to large problems. The common characteristics sharing the concept of DDET are as follows: • Both deterministic and stochastic approaches • Improves the identification of PSA success criteria • Helps to limit detrimental effects of sequence binning (normally adopted in PSA) • Helps to avoid defining non-optimal success criteria that may distort the risk • Framework for comprehensively considering

  11. Survey of Dynamic PSA Methodologies

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hansul; Kim, Hyeonmin; Heo, Gyunyoung [Kyung Hee University, Yongin (Korea, Republic of); Kim, Taewan [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2015-05-15

    Event Tree(ET)/Fault Tree(FT) are significant methodology in Probabilistic Safety Assessment(PSA) for Nuclear Power Plants(NPPs). ET/FT methodology has the advantage for users to be able to easily learn and model. It enables better communication between engineers engaged in the same field. However, conventional methodologies are difficult to cope with the dynamic behavior (e.g. operation mode changes or sequence-dependent failure) and integrated situation of mechanical failure and human errors. Meanwhile, new possibilities are coming for the improved PSA by virtue of the dramatic development on digital hardware, software, information technology, and data analysis.. More specifically, the computing environment has been greatly improved with being compared to the past, so we are able to conduct risk analysis with the large amount of data actually available. One method which can take the technological advantages aforementioned should be the dynamic PSA such that conventional ET/FT can have time- and condition-dependent behaviors in accident scenarios. In this paper, we investigated the various enabling techniques for the dynamic PSA. Even though its history and academic achievement was great, it seems less interesting from industrial and regulatory viewpoint. Authors expect this can contribute to better understanding of dynamic PSA in terms of algorithm, practice, and applicability. In paper, the overview for the dynamic PSA was conducted. Most of methodologies share similar concepts. Among them, DDET seems a backbone for most of methodologies since it can be applied to large problems. The common characteristics sharing the concept of DDET are as follows: • Both deterministic and stochastic approaches • Improves the identification of PSA success criteria • Helps to limit detrimental effects of sequence binning (normally adopted in PSA) • Helps to avoid defining non-optimal success criteria that may distort the risk • Framework for comprehensively considering

  12. Methodology - PSA Regulatory handbook. Comparisons to a modern PSA study

    International Nuclear Information System (INIS)

    Bostroem, Urban; Jung, Gunnar; Flodin, Yngve

    2003-03-01

    The regulatory handbook is applicable to all types of initiating events and all operating conditions. It should be noted that it does not make the traditional subdivision of PSA into internal and external events, level 1 and level 2 PSA, or power operation and shut-down. The reason for this is that this has given the regulatory handbook a more logical structure, and that this approach underlines the integrated character of PSA when it comes to creating the plan risk profile. The regulatory handbook has been structured following the requirements on a PSA for a nuclear power plant, as this is the most demanding application. However, it is applicable also to the analysis of other nuclear installations. The purpose of the comparative review presented in this report has been to, as part of a quality review establish the PSA Handbook, compare (parts of) the handbook and its criteria with a recent PSA analysis, and to identify major discrepancies. Considerable weight has also been allocated to a review of the plant model (Risk Spectrum event trees and fault trees). The results presented in the report are not based on a complete review of the PSA in question (or of the complete PSA Handbook). Following discussions between the SKI and SwedPower, and based on the experience of the SwedPower reviewers, the following issues were chosen to be the main parts of the project: 1) General comparison according to content and transparency - Levels of ambition in PSA Handbook, PSA method description and actual PSA report. 2) Detailed comparison of: Selected component failure data - Assumptions regarding room events - CCI frequencies, realism, identification, categorisation - Taking credit for non-safety classified systems - Event tree modelling - Presentation of results 3) Fault tree model, specifically - Time frame for crediting of battery capacity - Modelling of regulators - Modelling of dependencies for room events - general quality, like how the paper documentation and the logic

  13. Analytical tool for the periodic safety analysis of NPP according to the PSA guideline. Vol. 1

    International Nuclear Information System (INIS)

    Balfanz, H.P.; Boehme, E.; Musekamp, W.; Hussels, U.; Becker, G.; Behr, H.; Luettgert, H.

    1994-01-01

    The SAIS (Safety Analysis and Informationssystem) Programme System is based on an integrated data base, which consists of a plant-data and a PSA related data part. Using SAIS analyses can be performed by special tools, which are connected directly to the data base. Two main editors, RISA+ and DEDIT, are used for data base management. The access to the data base is done via different types of pages, which are displayed on a displayed on a computer screen. The pages are called data sheets. Sets of input and output data sheets were implemented, such as system or component data sheets, fault trees or event trees. All input information, models and results needed for updated results of PSA (Living PSA) can be stored in the SAIS. The programme system contains the editor KVIEW which guarantees consistency of the stored data, e.g. with respect to names and codes of components and events. The information contained in the data base are called in by a standardized users guide programme, called Page Editor. (Brunsbuettel on reference NPP). (orig./HP) [de

  14. Application of Melcor code for the calculo of TMLB sequence in PWR with natural circulating into the vessel

    International Nuclear Information System (INIS)

    Marten-Fuertes, F.

    1995-01-01

    The use of computer codes to analyze the phenomena of severe accidents is very important to take decisions in Nuclear Safety. This paper presents the MELCOR code used to calculate the TMLB sequence of PWR with natural circulation into the vessels. The main goal of this code is its application for the PSA (probabilistic safety analysis)

  15. Computer codes in particle transport physics

    International Nuclear Information System (INIS)

    Pesic, M.

    2004-01-01

    Simulation of transport and interaction of various particles in complex media and wide energy range (from 1 MeV up to 1 TeV) is very complicated problem that requires valid model of a real process in nature and appropriate solving tool - computer code and data library. A brief overview of computer codes based on Monte Carlo techniques for simulation of transport and interaction of hadrons and ions in wide energy range in three dimensional (3D) geometry is shown. Firstly, a short attention is paid to underline the approach to the solution of the problem - process in nature - by selection of the appropriate 3D model and corresponding tools - computer codes and cross sections data libraries. Process of data collection and evaluation from experimental measurements and theoretical approach to establishing reliable libraries of evaluated cross sections data is Ion g, difficult and not straightforward activity. For this reason, world reference data centers and specialized ones are acknowledged, together with the currently available, state of art evaluated nuclear data libraries, as the ENDF/B-VI, JEF, JENDL, CENDL, BROND, etc. Codes for experimental and theoretical data evaluations (e.g., SAMMY and GNASH) together with the codes for data processing (e.g., NJOY, PREPRO and GRUCON) are briefly described. Examples of data evaluation and data processing to generate computer usable data libraries are shown. Among numerous and various computer codes developed in transport physics of particles, the most general ones are described only: MCNPX, FLUKA and SHIELD. A short overview of basic application of these codes, physical models implemented with their limitations, energy ranges of particles and types of interactions, is given. General information about the codes covers also programming language, operation system, calculation speed and the code availability. An example of increasing computation speed of running MCNPX code using a MPI cluster compared to the code sequential option

  16. Detection of prostate cancer with complexed PSA and complexed/total PSA ratio - is there any advantage?

    OpenAIRE

    Strittmatter, F; Stieber, P; Nagel, D; Füllhase, C; Walther, S; Stief, CG; Waidelich, R

    2011-01-01

    Abstract Objective To evaluate the performance of total PSA (tPSA), the free/total PSA ratio (f/tPSA), complexed PSA (cPSA) and the complexed/total PSA ratio (c/tPSA) in prostate cancer detection. Methods Frozen sera of 442 patients have been analysed for tPSA, free PSA (fPSA) and cPSA. 131 patients had prostate cancer and 311 patients benign prostatic hyperplasia. Results Differences in the distribution of the biomarkers were seen as follows: tPSA, cPSA and c/tPSA were significantly higher i...

  17. PSA Update Procedures, an Ultimate Need for Living PSA

    International Nuclear Information System (INIS)

    Hegedus, D.

    1998-01-01

    Nuclear facilities by their complex nature, change with time. These changes can be both physical (plant modification, etc.), operational (enhanced procedures, etc.) and organizational. In addition, there are also changes in our understanding of the plant, due to operational experience, data collection, technology enhancements, etc. Therefore, it is imperative that PSA model must be frequently up-dated or modified to reflect these changes. Over the last ten years. these has been a remarkable growth of the use of Probabilistic Safety Assessments (PSAs). The most rapidly growing area of the PSA Applications is their use to support operational decision-making. Many of these applications are characterized by the potential for not only improving the safety level but also for providing guidance on the optimal use of resources and reducing regulatory burden. To enable a wider use of the PSA model as a tool for safety activities it is essential to maintain the model in a controlled state. Moreover, to fulfill requirements for L iving PSA , the PSA model has to be constantly updated and/or monitored to reflect the current plant configuration. It should be noted that the PSA model should not only represent the plant design but should also represent the operational and emergency procedures. To keep the PSA model up-to-date several issues should be clearly defined including: - Responsibility should be divided among the PSA group, - Procedures for implementing changes should be established, and - QA requirements/program should be established to assure documentation and reporting. (author)

  18. Use of computer codes for system reliability analysis

    International Nuclear Information System (INIS)

    Sabek, M.; Gaafar, M.; Poucet, A.

    1988-01-01

    This paper gives a collective summary of the studies performed at the JRC, ISPRA on the use of computer codes for complex systems analysis. The computer codes dealt with are: CAFTS-SALP software package, FRANTIC, FTAP, computer code package RALLY, and BOUNDS codes. Two reference study cases were executed by each code. The results obtained logic/probabilistic analysis as well as computation time are compared

  19. Translation of ARAC computer codes

    International Nuclear Information System (INIS)

    Takahashi, Kunio; Chino, Masamichi; Honma, Toshimitsu; Ishikawa, Hirohiko; Kai, Michiaki; Imai, Kazuhiko; Asai, Kiyoshi

    1982-05-01

    In 1981 we have translated the famous MATHEW, ADPIC and their auxiliary computer codes for CDC 7600 computer version to FACOM M-200's. The codes consist of a part of the Atmospheric Release Advisory Capability (ARAC) system of Lawrence Livermore National Laboratory (LLNL). The MATHEW is a code for three-dimensional wind field analysis. Using observed data, it calculates the mass-consistent wind field of grid cells by a variational method. The ADPIC is a code for three-dimensional concentration prediction of gases and particulates released to the atmosphere. It calculates concentrations in grid cells by the particle-in-cell method. They are written in LLLTRAN, i.e., LLNL Fortran language and are implemented on the CDC 7600 computers of LLNL. In this report, i) the computational methods of the MATHEW/ADPIC and their auxiliary codes, ii) comparisons of the calculated results with our JAERI particle-in-cell, and gaussian plume models, iii) translation procedures from the CDC version to FACOM M-200's, are described. Under the permission of LLNL G-Division, this report is published to keep the track of the translation procedures and to serve our JAERI researchers for comparisons and references of their works. (author)

  20. Putting PSA to work

    International Nuclear Information System (INIS)

    Gubler, R.; Gomez-Cobo, A.

    1998-01-01

    The IAEA has, during the last three years, been working intensively on PSA applications. The draft TECDOC prepared during these activities, ''PSA Applications'' is summarized in this paper. Actual events at nuclear facilities provide an important basis to compare PSAs with reality. PSA based operational event analysis therefore can be used to evaluate the importance of operational events from a risk perspective but also can contribute to validating and enhancing PSAs and to continuously check whether or not the PSA models are adequate, appropriate and complete. The work of the IAEA in this area is therefore summarized as well. In a companion paper, titled ''Towards a credible PSA fit for applications'', two specific aspects regarding the quality of the PSA to be used are discussed in detail, namely the Living PSA concept, which ensures that the PSA reflects actual design and operational features and Quality Assurance for PSA. (author)

  1. Computer code development plant for SMART design

    International Nuclear Information System (INIS)

    Bae, Kyoo Hwan; Choi, S.; Cho, B.H.; Kim, K.K.; Lee, J.C.; Kim, J.P.; Kim, J.H.; Chung, M.; Kang, D.J.; Chang, M.H.

    1999-03-01

    In accordance with the localization plan for the nuclear reactor design driven since the middle of 1980s, various computer codes have been transferred into the korea nuclear industry through the technical transfer program from the worldwide major pressurized water reactor supplier or through the international code development program. These computer codes have been successfully utilized in reactor and reload core design works. As the results, design- related technologies have been satisfactorily accumulated. However, the activities for the native code development activities to substitute the some important computer codes of which usages are limited by the original technique owners have been carried out rather poorly. Thus, it is most preferentially required to secure the native techniques on the computer code package and analysis methodology in order to establish the capability required for the independent design of our own model of reactor. Moreover, differently from the large capacity loop-type commercial reactors, SMART (SYSTEM-integrated Modular Advanced ReacTor) design adopts a single reactor pressure vessel containing the major primary components and has peculiar design characteristics such as self-controlled gas pressurizer, helical steam generator, passive residual heat removal system, etc. Considering those peculiar design characteristics for SMART, part of design can be performed with the computer codes used for the loop-type commercial reactor design. However, most of those computer codes are not directly applicable to the design of an integral reactor such as SMART. Thus, they should be modified to deal with the peculiar design characteristics of SMART. In addition to the modification efforts, various codes should be developed in several design area. Furthermore, modified or newly developed codes should be verified their reliability through the benchmarking or the test for the object design. Thus, it is necessary to proceed the design according to the

  2. Computer code development plant for SMART design

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Kyoo Hwan; Choi, S.; Cho, B.H.; Kim, K.K.; Lee, J.C.; Kim, J.P.; Kim, J.H.; Chung, M.; Kang, D.J.; Chang, M.H

    1999-03-01

    In accordance with the localization plan for the nuclear reactor design driven since the middle of 1980s, various computer codes have been transferred into the korea nuclear industry through the technical transfer program from the worldwide major pressurized water reactor supplier or through the international code development program. These computer codes have been successfully utilized in reactor and reload core design works. As the results, design- related technologies have been satisfactorily accumulated. However, the activities for the native code development activities to substitute the some important computer codes of which usages are limited by the original technique owners have been carried out rather poorly. Thus, it is most preferentially required to secure the native techniques on the computer code package and analysis methodology in order to establish the capability required for the independent design of our own model of reactor. Moreover, differently from the large capacity loop-type commercial reactors, SMART (SYSTEM-integrated Modular Advanced ReacTor) design adopts a single reactor pressure vessel containing the major primary components and has peculiar design characteristics such as self-controlled gas pressurizer, helical steam generator, passive residual heat removal system, etc. Considering those peculiar design characteristics for SMART, part of design can be performed with the computer codes used for the loop-type commercial reactor design. However, most of those computer codes are not directly applicable to the design of an integral reactor such as SMART. Thus, they should be modified to deal with the peculiar design characteristics of SMART. In addition to the modification efforts, various codes should be developed in several design area. Furthermore, modified or newly developed codes should be verified their reliability through the benchmarking or the test for the object design. Thus, it is necessary to proceed the design according to the

  3. PSA Level 2 as element of an integral safety assessment before plant commissioning

    International Nuclear Information System (INIS)

    Loeffler, H.; Mildenberger, O.; Sonnenkalb, M.; Steinroetter, T.

    2012-01-01

    In Argentina the Central Nuclear Atucha II is near to completion. This is a pressurized heavy water reactor. PSA (Probability Safety Assessment) level 1, level 2 and level 3 have to be performed in order to show compliance with the Argentinean dose limit. Such studies have been done first by the former KWU in the 1980's to get the construction license (FABIAN 1985). Nowadays the plant owner NA-SA performs PSA level 1 and provides information about the core damage states to GRS, who does the subsequent PSA level 2 part. GRS delivers source terms to the environment and the associated frequencies to the Argentinean research institute CNEA, which performs level 3 together with NA-SA. Since GRS is situated in the middle of the chain, interface definition with both ends has been a significant task of the GRS activities. Experience gained during this process will be highlighted in the presentation. The analysis of PSA level 2 proper follows a traditional approach: -) deterministic accident simulation with integral code MELCOR; -) analyses of specific issues which are not covered by MELCOR; and -) probabilistic accident progression analysis with EVNTRE event tree methodology. It appears that MELCOR and EVNTRE and PSA guidelines in general are flexible enough to analyse new or uncommon reactor designs. It also appears that the plant specific design features may require analyses beyond present code capabilities, calling for expert judgment and they can largely determine PSA results. The behaviour of iodine is not yet covered satisfactorily by state-of-the-art models in MELCOR

  4. Vergleichende Einschätzung der diagnostischen Aussagekraft der Kenngrößen freies PSA, Alpha1-Antichymotrypsin-PSA und komplexiertes PSA in der Diagnostik des Prostatakarzinoms

    OpenAIRE

    Baumgart E; Deger S; Jung K; Lein M; Loening SA; Schnorr D

    2001-01-01

    Ziel der Studie war die vergleichende Einschätzung der diagnostischen Aussagekraft von Gesamt-PSA (tPSA), freiem PSA (fPSA), alpha1-Antichymotrypsin-PSA (ACT-PSA) und komplexiertem PSA (cPSA) sowie der entsprechenden Quotienten zur Differenzierung zwischen einem Prostatakarzinom (PCa) und einer Benignen Prostatahyperplasie (BPH). Die Bestimmung erfolgte bei insgesamt 324 Männern (PCa: n = 144; BPH: n = 89; Kontrollen: n = 91). Die tPSA- und cPSA-Konzentrationen wurden mit dem Bayer Immuno 1 S...

  5. Determining if pretreatment PSA doubling time predicts PSA trajectories after radiation therapy for localized prostate cancer

    International Nuclear Information System (INIS)

    Soto, Daniel E.; Andridge, Rebecca R.; Pan, Charlie C.; Williams, Scott G.; Taylor, Jeremy M.G.; Sandler, Howard M.

    2009-01-01

    Introduction: To determine if pretreatment PSA doubling time (PSA-DT) can predict post-radiation therapy (RT) PSA trajectories for localized prostate cancer. Materials and methods: Three hundred and seventy-five prostate cancer patients treated with external beam RT without androgen deprivation therapy (ADT) were identified with an adequate number of PSA values. We utilized a linear mixed model (LMM) analysis to model longitudinal PSA data sets after definitive treatment. Post-treatment PSA trajectories were allowed to depend on the pre-RT PSA-DT, pre-RT PSA (iPSA), Gleason score (GS), and T-stage. Results: Pre-RT PSA-DT had a borderline impact on predicting the rate of PSA rise after nadir (p = 0.08). For a typical low risk patient (T1, GS ≤ 6, iPSA 10), the predicted PSA-DT post-nadir was 21% shorter for pre-RT PSA-DT 24 month (19 month vs. 24 month). Additional significant predictors of post-RT PSA rate of rise included GS (p < 0.0001), iPSA (p < 0.0001), and T-stage (p = 0.02). Conclusions: We observed a trend between rapidly rising pre-RT PSA and the post-RT post-nadir PSA rise. This effect appeared to be independent of iPSA, GS, or T-stage. The results presented suggest that pretreatment PSA-DT may help predict post-RT PSA trajectories

  6. Re-examining Prostate-specific Antigen (PSA) Density: Defining the Optimal PSA Range and Patients for Using PSA Density to Predict Prostate Cancer Using Extended Template Biopsy.

    Science.gov (United States)

    Jue, Joshua S; Barboza, Marcelo Panizzutti; Prakash, Nachiketh S; Venkatramani, Vivek; Sinha, Varsha R; Pavan, Nicola; Nahar, Bruno; Kanabur, Pratik; Ahdoot, Michael; Dong, Yan; Satyanarayana, Ramgopal; Parekh, Dipen J; Punnen, Sanoj

    2017-07-01

    To compare the predictive accuracy of prostate-specific antigen (PSA) density vs PSA across different PSA ranges and by prior biopsy status in a prospective cohort undergoing prostate biopsy. Men from a prospective trial underwent an extended template biopsy to evaluate for prostate cancer at 26 sites throughout the United States. The area under the receiver operating curve assessed the predictive accuracy of PSA density vs PSA across 3 PSA ranges (10 ng/mL). We also investigated the effect of varying the PSA density cutoffs on the detection of cancer and assessed the performance of PSA density vs PSA in men with or without a prior negative biopsy. Among 1290 patients, 585 (45%) and 284 (22%) men had prostate cancer and significant prostate cancer, respectively. PSA density performed better than PSA in detecting any prostate cancer within a PSA of 4-10 ng/mL (area under the receiver operating characteristic curve [AUC]: 0.70 vs 0.53, P PSA >10 mg/mL (AUC: 0.84 vs 0.65, P PSA density was significantly more predictive than PSA in detecting any prostate cancer in men without (AUC: 0.73 vs 0.67, P PSA increases, PSA density becomes a better marker for predicting prostate cancer compared with PSA alone. Additionally, PSA density performed better than PSA in men with a prior negative biopsy. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Development and verification of a leningrad NPP unit 1 living PSA model in the INL SAPHIRE code format for prompt operational safety level monitoring

    International Nuclear Information System (INIS)

    Bronislav, Vinnikov

    2007-01-01

    The first part of the paper presents results of the work, that was carried out in complete conformity with the Technical Assignment, which was developed by the Leningrad Nuclear Power Plant. The initial scientific and technical information, contained into the In-Depth Safety Assessment Reports, was given to the author of the work. This information included graphical Fault Trees of Safety Systems and Auxiliary Technical Systems, Event Trees for the necessary number of Initial Events, and also information about failure probabilities of basic components of the nuclear unit. On the basis of this information and fueling it to the Usa Idaho National Laboratory (INL) SAPHIRE code, we have developed an electronic version of the Data Base for failure probabilities of the components of technical systems. Then, we have developed both the electronic versions of the necessary Fault Trees, and an electronic versions of the necessary Event Trees. And at last, we have carried out the linkage of the Event Trees. This work has resulted in the Living PSA (LPSA - Living Probabilistic Safety Assessment) Model of the Leningrad NPP Unit 1. The LPSA-model is completely adapted to be consistent with the USA INL SAPHIRE Risk Monitor. The second part of the paper results in analysis of fire consequences in various places of Leningrad NPP Unit 1. The computations were carried out with the help of the LPSA-model, developed in SAPHIRE code format. On the basis of the computations the order of priority of implementation of fire prevention measures was established. (author)

  8. Adaptation of HAMMER computer code to CYBER 170/750 computer

    International Nuclear Information System (INIS)

    Pinheiro, A.M.B.S.; Nair, R.P.K.

    1982-01-01

    The adaptation of HAMMER computer code to CYBER 170/750 computer is presented. The HAMMER code calculates cell parameters by multigroup transport theory and reactor parameters by few group diffusion theory. The auxiliary programs, the carried out modifications and the use of HAMMER system adapted to CYBER 170/750 computer are described. (M.C.K.) [pt

  9. Level 1 PSA study of Mochovce unit 1 NPP (SM AA 10 and 08)

    International Nuclear Information System (INIS)

    Cillik, I.

    1997-01-01

    This paper presents genesis of Level 1 PSA project preparation for all operational modes of Mochovce NPP unit 1 including the description of its' main objectives, scope and working method. The PSA study which includes full power (FPSA) as well as shutdown and low power conditions (SPSA) Level 1 PSA has to support the nuclear safety improvements of the unit. They evaluate the basic design and the benefits of all improvements, which were found necessary to be incorporated before the start-up of the unit. The study includes internal events (transients and under-loss of coolant accident, LOCAs), internal hazards as fires and floods and selected external hazards as earthquake, influence of external industry, extreme meteorological conditions and aircraft crash.The PSA (both FPSA and SPSA) models is developed using the RISK SPECTRUM PSA code. (author)

  10. Influence of PSA, PSA velocity and PSA doubling time on contrast-enhanced 18F-choline PET/CT detection rate in patients with rising PSA after radical prostatectomy

    International Nuclear Information System (INIS)

    Schillaci, Orazio; Calabria, Ferdinando; Tavolozza, Mario; Caracciolo, Cristiana Ragano; Orlacchio, Antonio; Danieli, Roberta; Simonetti, Giovanni; Agro, Enrico Finazzi; Miano, Roberto

    2012-01-01

    To evaluate the accuracy of contrast-enhanced 18 F-choline PET/CT in restaging patients with prostate cancer after radical prostatectomy in relation to PSA, PSA velocity (PSAve) and PSA doubling time (PSAdt). PET/CT was performed in 49 patients (age range 58-87 years) with rising PSA (mean 4.13 ng/ml) who were divided in four groups according to PSA level: ≤1 ng/ml, 1 to ≤2 ng/ml, 2 to ≤4 ng/ml, and >4 ng/ml. PSAve and PSAdt were measured. PET and CT scans were interpreted separately and then together. PET/CT diagnosed relapse in 33 of the 49 patients (67%). The detection rates were 20%, 55%, 80% and 87% in the PSA groups ≤1, 1 to ≤2, 2 to ≤4 and >4 ng/ml, respectively. PET/CT was positive in 7 of 18 patients (38.9%) with a PSA ≤2 ng/ml, and in 26 of 31 (83.9%) with a PSA >2 ng/ml. PET/CT was positive in 7 of 25 patients (84%) with PSAdt ≤6 months, and in 12 of 24 patients (50%) with PSAdt >6 months, and was positive in 26 of 30 patients (86%) with a PSAve >2 ng/ml per year, and in 7 of 19 patients (36.8%) with PSAve ≤2 ng/ml per year. PET alone was positive in 31 of 49 patients (63.3%), and of these 31 patients, CT was negative in 14 but diagnosed bone lesions in 2 patients in whom PET alone was negative. CT with the administration of intravenous contrast medium did not provide any further information. Detection rate of 18 F-choline imaging is closely related to PSA and PSA kinetics. In particular, 18 F-choline PET/CT is recommended in patients with PSA >2 ng/ml, PSAdt ≤6 months and PSAve >2 ng/ml per year. CT is useful for detecting bone metastases that are not 18 F-choline-avid. The use of intravenous contrast agent seems unnecessary. (orig.)

  11. Verification of SACI-2 computer code comparing with experimental results of BIBLIS-A and LOOP-7 computer code

    International Nuclear Information System (INIS)

    Soares, P.A.; Sirimarco, L.F.

    1984-01-01

    SACI-2 is a computer code created to study the dynamic behaviour of a PWR nuclear power plant. To evaluate the quality of its results, SACI-2 was used to recalculate commissioning tests done in BIBLIS-A nuclear power plant and to calculate postulated transients for Angra-2 reactor. The results of SACI-2 computer code from BIBLIS-A showed as much good agreement as those calculated with the KWU Loop 7 computer code for Angra-2. (E.G.) [pt

  12. APC: A new code for Atmospheric Polarization Computations

    International Nuclear Information System (INIS)

    Korkin, Sergey V.; Lyapustin, Alexei I.; Rozanov, Vladimir V.

    2013-01-01

    A new polarized radiative transfer code Atmospheric Polarization Computations (APC) is described. The code is based on separation of the diffuse light field into anisotropic and smooth (regular) parts. The anisotropic part is computed analytically. The smooth regular part is computed numerically using the discrete ordinates method. Vertical stratification of the atmosphere, common types of bidirectional surface reflection and scattering by spherical particles or spheroids are included. A particular consideration is given to computation of the bidirectional polarization distribution function (BPDF) of the waved ocean surface. -- Highlights: •A new code, APC, has been developed. •The code was validated against well-known codes. •The BPDF for an arbitrary Mueller matrix is computed

  13. The RETRAN-03 computer code

    International Nuclear Information System (INIS)

    Paulsen, M.P.; McFadden, J.H.; Peterson, C.E.; McClure, J.A.; Gose, G.C.; Jensen, P.J.

    1991-01-01

    The RETRAN-03 code development effort is designed to overcome the major theoretical and practical limitations associated with the RETRAN-02 computer code. The major objectives of the development program are to extend the range of analyses that can be performed with RETRAN, to make the code more dependable and faster running, and to have a more transportable code. The first two objectives are accomplished by developing new models and adding other models to the RETRAN-02 base code. The major model additions for RETRAN-03 are as follows: implicit solution methods for the steady-state and transient forms of the field equations; additional options for the velocity difference equation; a new steady-state initialization option for computer low-power steam generator initial conditions; models for nonequilibrium thermodynamic conditions; and several special-purpose models. The source code and the environmental library for RETRAN-03 are written in standard FORTRAN 77, which allows the last objective to be fulfilled. Some models in RETRAN-02 have been deleted in RETRAN-03. In this paper the changes between RETRAN-02 and RETRAN-03 are reviewed

  14. The diagnostic value of PSA, cPSA and bone scintigraphy for early skeletal metastasis of prostate cancer

    International Nuclear Information System (INIS)

    Xue Zhongguang

    2007-01-01

    Objective: To evaluate the value of prostate specific antigen (PSA), complexed prostate specific antigen (cPSA) and bone scintigraphic imaging in diagnosis of early skeletal metastasis of prostate cancer. Methods: 152 patients (74 with prostate cancer, 78 with benign prostate disease) and 90 controls were examined for the serum concentrations of PSA and cPSA. At the same time, the 74 patients with PCa were examined with bone scintigraphy. The cPSA/PSA ratio was calculated. Results: Serum PSA, cPSA levels and cPSA/PSA ratio of patients with prostate cancer were significantly higher than those in benign prostate patients and controls. In addition, the serum PSA, cPSA levels and cPSA/PSA ratio in prostate cancer patients with skeletal metastasis were remarkably higher than those in patients without skeletal metastasis, and the differences were significant (P 20 μg/L, cPSA>10 μg/L, cPSA/PSA>0.80, there is a high probability that skeletal metastasis of prostate cancer would be present and bone scintigraphy should be performed. (authors)

  15. Computation of the bounce-average code

    International Nuclear Information System (INIS)

    Cutler, T.A.; Pearlstein, L.D.; Rensink, M.E.

    1977-01-01

    The bounce-average computer code simulates the two-dimensional velocity transport of ions in a mirror machine. The code evaluates and bounce-averages the collision operator and sources along the field line. A self-consistent equilibrium magnetic field is also computed using the long-thin approximation. Optionally included are terms that maintain μ, J invariance as the magnetic field changes in time. The assumptions and analysis that form the foundation of the bounce-average code are described. When references can be cited, the required results are merely stated and explained briefly. A listing of the code is appended

  16. Experience in PSA fault tree modularization at the ASCO NPP

    International Nuclear Information System (INIS)

    Nos Llorens, V.; Frances Urmeneta, M.; Fraig Sureda, J.

    1995-01-01

    Probabilistic Safety Analysis (PSA) is a basic tool in decision-making for the optimization of back fittings, procedures and maintenance practices. ASCO NPP PSA was developed with a high level of detail in the models. This required considerable computer resources (long running time) to carry out the quantification. The quantification time had therefore to be flexible to allow continuous evaluation of the impact on the estimation and reduction of risk in the plant, and also to facilitate post-PSA applications. The most suitable way of achieving this flexibility was by compacting and reducing the detailed fault trees of the project by means of a modularization process. The purpose of the paper is to present the practical experience acquired with modularization carried out in the UTE UNITEC-INYPSA-EMPRESARIOS AGRUPADOS framework and the method applied, the support computer programs devised and their degree of effectiveness. (Author)

  17. Influence of PSA, PSA velocity and PSA doubling time on contrast-enhanced {sup 18}F-choline PET/CT detection rate in patients with rising PSA after radical prostatectomy

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, Orazio [University ' ' Tor Vergata' ' , Department of Biopathology and Diagnostic Imaging, Interventional, Rome (Italy); IRCCS Neuromed, Department of Nuclear Medicine and Molecular Imaging, Pozzilli (Italy); Calabria, Ferdinando [IRCCS Neuromed, Department of Nuclear Medicine and Molecular Imaging, Pozzilli (Italy); Tavolozza, Mario; Caracciolo, Cristiana Ragano; Orlacchio, Antonio; Danieli, Roberta; Simonetti, Giovanni [University ' ' Tor Vergata' ' , Department of Biopathology and Diagnostic Imaging, Interventional, Rome (Italy); Agro, Enrico Finazzi; Miano, Roberto [University Hospital ' ' Tor Vergata' ' , Department of Urology, Rome (Italy)

    2012-04-15

    To evaluate the accuracy of contrast-enhanced {sup 18}F-choline PET/CT in restaging patients with prostate cancer after radical prostatectomy in relation to PSA, PSA velocity (PSAve) and PSA doubling time (PSAdt). PET/CT was performed in 49 patients (age range 58-87 years) with rising PSA (mean 4.13 ng/ml) who were divided in four groups according to PSA level: {<=}1 ng/ml, 1 to {<=}2 ng/ml, 2 to {<=}4 ng/ml, and >4 ng/ml. PSAve and PSAdt were measured. PET and CT scans were interpreted separately and then together. PET/CT diagnosed relapse in 33 of the 49 patients (67%). The detection rates were 20%, 55%, 80% and 87% in the PSA groups {<=}1, 1 to {<=}2, 2 to {<=}4 and >4 ng/ml, respectively. PET/CT was positive in 7 of 18 patients (38.9%) with a PSA {<=}2 ng/ml, and in 26 of 31 (83.9%) with a PSA >2 ng/ml. PET/CT was positive in 7 of 25 patients (84%) with PSAdt {<=}6 months, and in 12 of 24 patients (50%) with PSAdt >6 months, and was positive in 26 of 30 patients (86%) with a PSAve >2 ng/ml per year, and in 7 of 19 patients (36.8%) with PSAve {<=}2 ng/ml per year. PET alone was positive in 31 of 49 patients (63.3%), and of these 31 patients, CT was negative in 14 but diagnosed bone lesions in 2 patients in whom PET alone was negative. CT with the administration of intravenous contrast medium did not provide any further information. Detection rate of {sup 18}F-choline imaging is closely related to PSA and PSA kinetics. In particular, {sup 18}F-choline PET/CT is recommended in patients with PSA >2 ng/ml, PSAdt {<=}6 months and PSAve >2 ng/ml per year. CT is useful for detecting bone metastases that are not {sup 18}F-choline-avid. The use of intravenous contrast agent seems unnecessary. (orig.)

  18. Implatation of MC2 computer code

    International Nuclear Information System (INIS)

    Seehusen, J.; Nair, R.P.K.; Becceneri, J.C.

    1981-01-01

    The implantation of MC2 computer code in the CDC system is presented. The MC2 computer code calculates multigroup cross sections for tipical compositions of fast reactors. The multigroup constants are calculated using solutions of PI or BI approximations for determined buckling value as weighting function. (M.C.K.) [pt

  19. Cloud Computing for Complex Performance Codes.

    Energy Technology Data Exchange (ETDEWEB)

    Appel, Gordon John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hadgu, Teklu [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Klein, Brandon Thorin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Miner, John Gifford [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-02-01

    This report describes the use of cloud computing services for running complex public domain performance assessment problems. The work consisted of two phases: Phase 1 was to demonstrate complex codes, on several differently configured servers, could run and compute trivial small scale problems in a commercial cloud infrastructure. Phase 2 focused on proving non-trivial large scale problems could be computed in the commercial cloud environment. The cloud computing effort was successfully applied using codes of interest to the geohydrology and nuclear waste disposal modeling community.

  20. Living PSA

    International Nuclear Information System (INIS)

    Evans, M.G.K.

    1997-01-01

    The aim of this presentation is to gain an understanding of the requirements for a PSA to be considered a Living PSA. The presentation is divided into the following topics: Definition; Planning/Documentation; Task Performance; Maintenance; Management. 4 figs

  1. Computer codes for safety analysis

    International Nuclear Information System (INIS)

    Holland, D.F.

    1986-11-01

    Computer codes for fusion safety analysis have been under development in the United States for about a decade. This paper will discuss five codes that are currently under development by the Fusion Safety Program. The purpose and capability of each code will be presented, a sample given, followed by a discussion of the present status and future development plans

  2. Use of computer codes for system reliability analysis

    International Nuclear Information System (INIS)

    Sabek, M.; Gaafar, M.; Poucet, A.

    1989-01-01

    This paper gives a summary of studies performed at the JRC, ISPRA on the use of computer codes for complex systems analysis. The computer codes dealt with are: CAFTS-SALP software package, FRACTIC, FTAP, computer code package RALLY, and BOUNDS. Two reference case studies were executed by each code. The probabilistic results obtained, as well as the computation times are compared. The two cases studied are the auxiliary feedwater system of a 1300 MW PWR reactor and the emergency electrical power supply system. (author)

  3. Use of computer codes for system reliability analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sabek, M.; Gaafar, M. (Nuclear Regulatory and Safety Centre, Atomic Energy Authority, Cairo (Egypt)); Poucet, A. (Commission of the European Communities, Ispra (Italy). Joint Research Centre)

    1989-01-01

    This paper gives a summary of studies performed at the JRC, ISPRA on the use of computer codes for complex systems analysis. The computer codes dealt with are: CAFTS-SALP software package, FRACTIC, FTAP, computer code package RALLY, and BOUNDS. Two reference case studies were executed by each code. The probabilistic results obtained, as well as the computation times are compared. The two cases studied are the auxiliary feedwater system of a 1300 MW PWR reactor and the emergency electrical power supply system. (author).

  4. Correlative study of SPECT bone scan, serum tPSA and fPSA/tPSA ratio and the pathological grade of prostate cancer with bone metastasis

    International Nuclear Information System (INIS)

    Xu Haiqing; Duan Jun

    2011-01-01

    Objective: To study the rules and characteristics of SPECT bone scan, serum TPSA, fPSA/tPSA ratio and the pathological grade of prostate cancer with bone metastasis. Methods: Nuclear medicine SPECT bone scan as the gold standard, retrospective analysis of the in vitro radioimmunoassay in 107 patients with prostate cancer serum PSA (prostate specific antigen) levels, serum fPSA/tPSA ratio and whole body bone imaging studies and pathological classification. Results: 107 patients with prostate cancer : 49 patients had bone metastases, accounting for 45.8% (49/107), in which groups of different pathological comparison between the incidence of bone metastasis significantly, the lower the degree of differentiation, the more the incidence of bone metastases high; with elevated levels of tPSA, the incidence of bone metastasis increased significantly; serum tPSA 4 - 40 ng/ml, the use of fPSA/tPSA ratio may improve the diagnostic specificity of prostate cancer. Conclusion: Patients with bone metastases of prostate cancer incidence and degree of differentiation of prostate cancer, serum PSA levels and fPSA/tPSA ratio of a certain relationship. The lower degree of differentiation,the higher the incidence of bone metastasis. (authors)

  5. The clinical study of serum PSA and fPSA assayed by CLIA in diagnosing prostate disease

    International Nuclear Information System (INIS)

    Xiong Jiang; Qian Xiaoyu; Ji Hong; Yang Su; Ding Ying; Zhu Ruisen; Chen Zhong

    2003-01-01

    The purpose of this study is to evaluate the clinical value of PSA (prostate specific antigen) and fPSA(free prostate specific antigen) in differentiating prostate disease. CLIA was used to quantitatively assay PSA, fPSA and fPSA/PSA in 30 cases of normal controls, 32 cases of prostate cancer patients and 76 cases of BPH patients. The result showed that if liminal value of PSA was set at 4 ng/mL, the diagnostic sensitivity and specificity of prostate cancer were 100% and 50.6% respectively. Meanwhile, if liminal value of fPSA/PSA set at 16% was added, the diagnostic sensitivity and specificity of prostate cancer were 100% and 85.3% respectively. It was concluded that the combining assay of PSA and fPSA could increase the diagnostic specificity of prostate cancer in a certain degree

  6. Can PSA Reflex Algorithm be a valid alternative to other PSA-based prostate cancer screening strategies?

    Science.gov (United States)

    Caldarelli, G; Troiano, G; Rosadini, D; Nante, N

    2017-01-01

    The available laboratory tests for the differential diagnosis of prostate cancer, are represented by the total PSA, the free PSA, and the free/total PSA ratio. In Italy most of doctors tend to request both total and free PSA for their patients even in cases where the total PSA doesn't justify the further request of free PSA, with a consequent growth of the costs for the National Health System. The aim of our study was to predict the saving in Euro (due to reagents) and reduction in free PSA tests, applying the "PSA Reflex" algorithm. We calculated the number of total PSA and free PSA exams performed in 2014 in the Hospital of Grosseto and, simulating the application of the "PSA Reflex" algorithm in the same year, we calculated the decrease in the number of free PSA requests and we tried to predict the Euro savings in reagents, obtained from this reduction. In 2014 in the Hospital of Grosseto 25,955 total PSA tests have been performed: 3,631 (14%) resulted greater than 10 ng / ml; 7,686 (29.6%) between 2 and 10 ng / ml; 14,638 (56.4%) lower than 2 ng / ml. The performed free PSA tests were 16904. Simulating the use of "PSA Reflex" algorithm, the free PSA tests would be performed only in cases with total PSA values between 2 and 10 ng / mL with a saving of 54.5% of free PSA exams and of 8,971 euros, only for reagents. Our study showed that the "PSA Reflex" algorithm is a valid alternative leading to a reduction of the costs. The estimated intralaboratory savings, due to the reagents, seem to be modest, however, they are followed by the additional savings due to the other diagnostic processes for prostate cancers.

  7. Computer-assisted Particle-in-Cell code development

    International Nuclear Information System (INIS)

    Kawata, S.; Boonmee, C.; Teramoto, T.; Drska, L.; Limpouch, J.; Liska, R.; Sinor, M.

    1997-12-01

    This report presents a new approach for an electromagnetic Particle-in-Cell (PIC) code development by a computer: in general PIC codes have a common structure, and consist of a particle pusher, a field solver, charge and current density collections, and a field interpolation. Because of the common feature, the main part of the PIC code can be mechanically developed on a computer. In this report we use the packages FIDE and GENTRAN of the REDUCE computer algebra system for discretizations of field equations and a particle equation, and for an automatic generation of Fortran codes. The approach proposed is successfully applied to the development of 1.5-dimensional PIC code. By using the generated PIC code the Weibel instability in a plasma is simulated. The obtained growth rate agrees well with the theoretical value. (author)

  8. Molecular Form Differences Between Prostate-Specific Antigen (PSA) Standards Create Quantitative Discordances in PSA ELISA Measurements

    Science.gov (United States)

    McJimpsey, Erica L.

    2016-02-01

    The prostate-specific antigen (PSA) assays currently employed for the detection of prostate cancer (PCa) lack the specificity needed to differentiate PCa from benign prostatic hyperplasia and have high false positive rates. The PSA calibrants used to create calibration curves in these assays are typically purified from seminal plasma and contain many molecular forms (intact PSA and cleaved subforms). The purpose of this study was to determine if the composition of the PSA molecular forms found in these PSA standards contribute to the lack of PSA test reliability. To this end, seminal plasma purified PSA standards from different commercial sources were investigated by western blot (WB) and in multiple research grade PSA ELISAs. The WB results revealed that all of the PSA standards contained different mass concentrations of intact and cleaved molecular forms. Increased mass concentrations of intact PSA yielded higher immunoassay absorbance values, even between lots from the same manufacturer. Standardization of seminal plasma derived PSA calibrant molecular form mass concentrations and purification methods will assist in closing the gaps in PCa testing measurements that require the use of PSA values, such as the % free PSA and Prostate Health Index by increasing the accuracy of the calibration curves.

  9. Computer codes for RF cavity design

    International Nuclear Information System (INIS)

    Ko, K.

    1992-08-01

    In RF cavity design, numerical modeling is assuming an increasingly important role with the help of sophisticated computer codes and powerful yet affordable computers. A description of the cavity codes in use in the accelerator community has been given previously. The present paper will address the latest developments and discuss their applications to cavity toning and matching problems

  10. Evaluation of total PSA assay on vitros ECi and correlation with Kryptor-PSA assay.

    Science.gov (United States)

    Cassinat, B; Wacquet, M; Toubert, M E; Rain, J D; Schlageter, M H

    2001-01-01

    An increasing number of multiparametric immuno-analysers for PSA assays are available. As different immuno-assays may vary in their analytical quality and their accuracy for the follow-up of patients, expertise is necessary for each new assay. The PSA assay on the Vitros-ECi analyser has been evaluated and compared with the PSA assay from the Kryptor analyser. Variation coefficients were 0.91 to 1.98% for within-run assays, and 4.2% to 5.4% for interassay (PSA levels = 0.8 microgram/L to 33.6 micrograms/L). Dilution tests showed 93 to 136% recovery until 70 micrograms/L PSA. Functional sensitivity was estimated at 0.03 microgram/L. Equimolarity of the test was confirmed. Correlation of PSA levels measured with Vitros-ECi and Kryptor analysers displayed a correlation coefficient r2 of 0.9716. The half-lives and doubling times of PSA were similar using both methods. Vitros-ECi PSA assay meets the major criteria for the management of prostate cancer patients.

  11. Probability of an Abnormal Screening PSA Result Based on Age, Race, and PSA Threshold

    Science.gov (United States)

    Espaldon, Roxanne; Kirby, Katharine A.; Fung, Kathy Z.; Hoffman, Richard M.; Powell, Adam A.; Freedland, Stephen J.; Walter, Louise C.

    2014-01-01

    Objective To determine the distribution of screening PSA values in older men and how different PSA thresholds affect the proportion of white, black, and Latino men who would have an abnormal screening result across advancing age groups. Methods We used linked national VA and Medicare data to determine the value of the first screening PSA test (ng/mL) of 327,284 men age 65+ who underwent PSA screening in the VA healthcare system in 2003. We calculated the proportion of men with an abnormal PSA result based on age, race, and common PSA thresholds. Results Among men age 65+, 8.4% had a PSA >4.0ng/mL. The percentage of men with a PSA >4.0ng/mL increased with age and was highest in black men (13.8%) versus white (8.0%) or Latino men (10.0%) (PPSA >4.0ng/mL ranged from 5.1% of Latino men age 65–69 to 27.4% of black men age 85+. Raising the PSA threshold from >4.0ng/mL to >10.0ng/mL, reclassified the greatest percentage of black men age 85+ (18.3% absolute change) and the lowest percentage of Latino men age 65–69 (4.8% absolute change) as being under the biopsy threshold (PPSA threshold together affect the pre-test probability of an abnormal screening PSA result. Based on screening PSA distributions, stopping screening among men whose PSA 10ng/ml has the greatest effect on reducing the number of older black men who will face biopsy decisions after screening. PMID:24439009

  12. Insights of PSA studies made for operating nuclear power stations in Finland

    International Nuclear Information System (INIS)

    Laaksonen, J.; Virolainen, R.

    1991-01-01

    In 1984 the Finnish regulatory authority (STUK) required the utilities to make plant specific probabilistic safety assessment (PSA) studies for each plant. It was also strongly recommended that most of the work be made by plant personnel. This advice was well observed by both utilities. Results of level 1 PSA studies were submitted for regulatory review in June 1989. Only internal initiating events, including loss-of-offsite power and human errors, were considered at this stage. Each study took an effort of 12 to 20 man years. A thorough regulatory review, about two man years per plant, is currently underway, and will cause some changes in the initial results of the studies. The utilities are continuing their PSA work with the fire and flood analysis, and then with the analysis of risks during start-up and shutdown conditions. As soon as a level 1 PSA study has been reviewed, and a common understanding of the models and data has been reached between the utility and the STUK, this basic PSA version will be the first element of a living PSA. The second element is a user friendly PSA code that can rapidly run through the quantitative part of the study and thus easily indicate the influence of any deviation from the basic version. The third element is plant specific data collection and processing system. The living PSA for the first plant is expected to be fully operational sometime next year. The first use of the living PSA will be the safety assessment of proposed plant modifications and a systematic re-evaluation of technical specifications

  13. Molecular Form Differences Between Prostate-Specific Antigen (PSA) Standards Create Quantitative Discordances in PSA ELISA Measurements

    Science.gov (United States)

    McJimpsey, Erica L.

    2016-01-01

    The prostate-specific antigen (PSA) assays currently employed for the detection of prostate cancer (PCa) lack the specificity needed to differentiate PCa from benign prostatic hyperplasia and have high false positive rates. The PSA calibrants used to create calibration curves in these assays are typically purified from seminal plasma and contain many molecular forms (intact PSA and cleaved subforms). The purpose of this study was to determine if the composition of the PSA molecular forms found in these PSA standards contribute to the lack of PSA test reliability. To this end, seminal plasma purified PSA standards from different commercial sources were investigated by western blot (WB) and in multiple research grade PSA ELISAs. The WB results revealed that all of the PSA standards contained different mass concentrations of intact and cleaved molecular forms. Increased mass concentrations of intact PSA yielded higher immunoassay absorbance values, even between lots from the same manufacturer. Standardization of seminal plasma derived PSA calibrant molecular form mass concentrations and purification methods will assist in closing the gaps in PCa testing measurements that require the use of PSA values, such as the % free PSA and Prostate Health Index by increasing the accuracy of the calibration curves. PMID:26911983

  14. Evaluating the Phoenix definition of biochemical failure after (125)I prostate brachytherapy: Can PSA kinetics distinguish PSA failures from PSA bounces?

    Science.gov (United States)

    Thompson, Anna; Keyes, Mira; Pickles, Tom; Palma, David; Moravan, Veronika; Spadinger, Ingrid; Lapointe, Vincent; Morris, W James

    2010-10-01

    To evaluate the prostate-specific antigen (PSA) kinetics of PSA failure (PSAf) and PSA bounce (PSAb) after permanent (125)I prostate brachytherapy (PB). The study included 1,006 consecutive low and "low tier" intermediate-risk patients treated with (125)I PB, with a potential minimum follow-up of 4 years. Patients who met the Phoenix definition of biochemical failure (nadir + 2 ng/mL(-1)) were identified. If the PSA subsequently fell to ≤0.5 ng/mL(-1)without intervention, this was considered a PSAb. All others were scored as true PSAf. Patient, tumor and dosimetric characteristics were compared between groups using the chi-square test and analysis of variance to evaluate factors associated with PSAf or PSAb. Median follow-up was 54 months. Of the 1,006 men, 57 patients triggered the Phoenix definition of PSA failure, 32 (56%) were true PSAf, and 25 PSAb (44%). The median time to trigger nadir + 2 was 20.6 months (range, 6-36) vs. 49 mo (range, 12-83) for PSAb vs. PSAf groups (p < 0.001). The PSAb patients were significantly younger (p < 0.0001), had shorter time to reach the nadir (median 6 vs. 11.5 months, p = 0.001) and had a shorter PSA doubling time (p = 0.05). Men younger than age 70 who trigger nadir +2 PSA failure within 38 months of implant have an 80% likelihood of having PSAb and 20% chance of PSAf. With adequate follow-up, 44% of PSA failures by the Phoenix definition in our cohort were found to be benign PSA bounces. Our study reinforces the need for adequate follow-up when reporting PB PSA outcomes, to ensure accurate estimates of treatment efficacy and to avoid unnecessary secondary interventions. 2010. Published by Elsevier Inc. All rights reserved.

  15. Evaluating the Phoenix Definition of Biochemical Failure After 125I Prostate Brachytherapy: Can PSA Kinetics Distinguish PSA Failures From PSA Bounces?

    International Nuclear Information System (INIS)

    Thompson, Anna; Keyes, Mira; Pickles, Tom

    2010-01-01

    Purpose: To evaluate the prostate-specific antigen (PSA) kinetics of PSA failure (PSAf) and PSA bounce (PSAb) after permanent 125 I prostate brachytherapy (PB). Methods and Materials: The study included 1,006 consecutive low and 'low tier' intermediate-risk patients treated with 125 I PB, with a potential minimum follow-up of 4 years. Patients who met the Phoenix definition of biochemical failure (nadir + 2 ng/mL -1 ) were identified. If the PSA subsequently fell to ≤0.5 ng/mL -1 without intervention, this was considered a PSAb. All others were scored as true PSAf. Patient, tumor and dosimetric characteristics were compared between groups using the chi-square test and analysis of variance to evaluate factors associated with PSAf or PSAb. Results: Median follow-up was 54 months. Of the 1,006 men, 57 patients triggered the Phoenix definition of PSA failure, 32 (56%) were true PSAf, and 25 PSAb (44%). The median time to trigger nadir + 2 was 20.6 months (range, 6-36) vs. 49 mo (range, 12-83) for PSAb vs. PSAf groups (p < 0.001). The PSAb patients were significantly younger (p < 0.0001), had shorter time to reach the nadir (median 6 vs. 11.5 months, p = 0.001) and had a shorter PSA doubling time (p = 0.05). Men younger than age 70 who trigger nadir +2 PSA failure within 38 months of implant have an 80% likelihood of having PSAb and 20% chance of PSAf. Conclusions: With adequate follow-up, 44% of PSA failures by the Phoenix definition in our cohort were found to be benign PSA bounces. Our study reinforces the need for adequate follow-up when reporting PB PSA outcomes, to ensure accurate estimates of treatment efficacy and to avoid unnecessary secondary interventions.

  16. Computer codes for RF cavity design

    International Nuclear Information System (INIS)

    Ko, K.

    1992-01-01

    In RF cavity design, numerical modeling is assuming an increasingly important role with the help of sophisticated computer codes and powerful yet affordable computers. A description of the cavity codes in use in the accelerator community has been given previously. The present paper will address the latest developments and discuss their applications to cavity tuning and matching problems. (Author) 8 refs., 10 figs

  17. Computer access security code system

    Science.gov (United States)

    Collins, Earl R., Jr. (Inventor)

    1990-01-01

    A security code system for controlling access to computer and computer-controlled entry situations comprises a plurality of subsets of alpha-numeric characters disposed in random order in matrices of at least two dimensions forming theoretical rectangles, cubes, etc., such that when access is desired, at least one pair of previously unused character subsets not found in the same row or column of the matrix is chosen at random and transmitted by the computer. The proper response to gain access is transmittal of subsets which complete the rectangle, and/or a parallelepiped whose opposite corners were defined by first groups of code. Once used, subsets are not used again to absolutely defeat unauthorized access by eavesdropping, and the like.

  18. Microgravity computing codes. User's guide

    Science.gov (United States)

    1982-01-01

    Codes used in microgravity experiments to compute fluid parameters and to obtain data graphically are introduced. The computer programs are stored on two diskettes, compatible with the floppy disk drives of the Apple 2. Two versions of both disks are available (DOS-2 and DOS-3). The codes are written in BASIC and are structured as interactive programs. Interaction takes place through the keyboard of any Apple 2-48K standard system with single floppy disk drive. The programs are protected against wrong commands given by the operator. The programs are described step by step in the same order as the instructions displayed on the monitor. Most of these instructions are shown, with samples of computation and of graphics.

  19. CONCEPT computer code

    International Nuclear Information System (INIS)

    Delene, J.

    1984-01-01

    CONCEPT is a computer code that will provide conceptual capital investment cost estimates for nuclear and coal-fired power plants. The code can develop an estimate for construction at any point in time. Any unit size within the range of about 400 to 1300 MW electric may be selected. Any of 23 reference site locations across the United States and Canada may be selected. PWR, BWR, and coal-fired plants burning high-sulfur and low-sulfur coal can be estimated. Multiple-unit plants can be estimated. Costs due to escalation/inflation and interest during construction are calculated

  20. 40 CFR 194.23 - Models and computer codes.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Models and computer codes. 194.23... General Requirements § 194.23 Models and computer codes. (a) Any compliance application shall include: (1... obtain stable solutions; (iv) Computer models accurately implement the numerical models; i.e., computer...

  1. Impact of total PSA, PSA doubling time and PSA velocity on detection rates of 11C-Choline positron emission tomography in recurrent prostate cancer

    NARCIS (Netherlands)

    Rybalov, Maxim; Breeuwsma, Anthonius J.; Leliveld, Anna M.; Pruim, Jan; Dierckx, Rudi A.; de Jong, Igle J.

    PURPOSE: To evaluate the effect of total PSA (tPSA) and PSA kinetics on the detection rates of (11)C-Choline PET in patients with biochemical recurrence (BCR) after radical prostatectomy (RP) or external beam radiotherapy (EBRT). METHODS: We included 185 patients with BCR after RP (PSA >0.2 ng/ml)

  2. NPP Krsko Living PSA Concept

    International Nuclear Information System (INIS)

    Vrbanic, I.; Spiler, J.

    2000-01-01

    NPP Krsko developed PSA model of internal and external initiators within the frame of the Individual Plant Examination (IPE) project. Within this project PSA model was used to examine the existing plant design features. In order to continue with use of this PSA model upon the completion of IPE in various risk-informed applications in support of plant operation and evaluations of design changes, an appropriate living PSA concept needed to be defined. The Living PSA concept is in NPP Krsko considered as being a set of activities pursued in order to update existing PSA model in a manner that it appropriately represents the plant design, operation practice and history. Only a PSA model which is being updated in this manner can serve as a platform for plant-specific risk informed applications. The NPP Krsko living PSA concept is based on the following major ponts. First, the baseline PSA model is defined, which is to be maintained and updated and which is to be reference point for any risk-informed application. Second, issues having a potential for impact on baseline PSA model are identified and procedure and responsibilities for their permanent monitoring and evaluation are established. Third, manner is defined in which consequential changes to baseline PSA model are implemented and controlled, together with associated responsibilities. Finally, the process is defined by which the existing version of baseline PSA model is superseded by a new one. Each time a new version of baseline PSA model is released, it would be re-quantified and the results evaluated and interpreted. By documenting these re-quantifications and evaluations of results in a sequence, the track is being kept of changes in long-term averaged risk perspective, represented by long-term averaged frequencies of core damage and pre-defined release categories. These major topics of NPP Krsko living PSA concept are presented and discussed in the paper. (author)

  3. Workshop on PSA applications, Sofia, Bulgaria, 7-11 October 1996. Lecturing materials

    International Nuclear Information System (INIS)

    1997-01-01

    The objective of this workshop was to present detailed, systematic and useful information about PSA-based tools and PSA applications. The first presentation of the workshop was titled ''The role of PSA in safety management''. This topic served to introduce the workshop and to highlight several concepts that were afterwards stressed during the week, i.e. the defence in depth principle and the use of deterministic and probabilistic approaches in a complementary way. This presentation provided a basis for the discussion of ''PSA applications''. As a complement to the theoretical lectures, there was a workshop during which three different exercises were run in parallel. For two of these, computer-based PSA tools were used. One of them was focused towards the analysis of design modifications and the other one towards demonstrating configuration control strategies. The objective of the third practice was to obtain Allowed Outage Times using different PSA-based approaches and to discuss the differences observed and the insights obtained. To conclude the workshop, stress was put on the importance of the quality of the PSA (the development of a high quality Living PSA should be the first step), the necessity to be cautious (before taking decisions both the qualitative and numerical results should be carefully analyzed), and the logical order for the implementation of PSA applications. Refs, figs, tabs

  4. Antigenic determinants of prostate-specific antigen (PSA) and development of assays specific for different forms of PSA.

    OpenAIRE

    Nilsson, O.; Peter, A.; Andersson, I.; Nilsson, K.; Grundstr?m, B.; Karlsson, B.

    1997-01-01

    Monoclonal antibodies were raised against prostate-specific antigen (PSA) by immunization with purified free PSA, i.e. not in complex with any protease inhibitor (F-PSA) and PSA in complex with alpha1-anti-chymotrypsin (PSA-ACT). Epitope mapping of PSA using the established monoclonal antibody revealed a complex pattern of independent and partly overlapping antigenic domains in the PSA molecule. Four independent antigenic domains and at least three partly overlapping domains were exposed both...

  5. Development of PSA workstation KIRAP

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Un; Han, Sang Hoon; Kim, Kil You; Yang, Jun Eon; Jeong, Won Dae; Chang, Seung Cheol; Sung, Tae Yong; Kang, Dae Il; Park, Jin Hee; Lee, Yoon Hwan; Hwang, Mi Jeong

    1997-01-01

    Advanced Research Group of Korea Atomic Energy Research Institute has been developing the Probabilistic Safety Assessment(PSA) workstation KIRAP from 1992. This report describes the recent development activities of PSA workstation KIRAP. The first is to develop and improve the methodologies for PSA quantification, that are the incorporation of fault tree modularization technique, the improvement of cut set generation method, the development of rule-based recovery, the development of methodology to solve a fault tree which has the logical loops and to handle a fault tree which has several initiators. These methodologies are incorporated in the PSA quantification software KIRAP-CUT. The second is to convert PSA modeling softwares for Windows, which have been used on the DOS environment since 1987. The developed softwares are the fault tree editor KWTREE, the event tree editor CONPAS, and Data manager KWDBMAN for event data and common cause failure (CCF) data. With the development of PSA workstation, it makes PSA modeling and PSA quantification and automation easier and faster. (author). 8 refs.

  6. Development of PSA workstation KIRAP

    International Nuclear Information System (INIS)

    Kim, Tae Un; Han, Sang Hoon; Kim, Kil You; Yang, Jun Eon; Jeong, Won Dae; Chang, Seung Cheol; Sung, Tae Yong; Kang, Dae Il; Park, Jin Hee; Lee, Yoon Hwan; Hwang, Mi Jeong.

    1997-01-01

    Advanced Research Group of Korea Atomic Energy Research Institute has been developing the Probabilistic Safety Assessment(PSA) workstation KIRAP from 1992. This report describes the recent development activities of PSA workstation KIRAP. The first is to develop and improve the methodologies for PSA quantification, that are the incorporation of fault tree modularization technique, the improvement of cut set generation method, the development of rule-based recovery, the development of methodology to solve a fault tree which has the logical loops and to handle a fault tree which has several initiators. These methodologies are incorporated in the PSA quantification software KIRAP-CUT. The second is to convert PSA modeling softwares for Windows, which have been used on the DOS environment since 1987. The developed softwares are the fault tree editor KWTREE, the event tree editor CONPAS, and Data manager KWDBMAN for event data and common cause failure (CCF) data. With the development of PSA workstation, it makes PSA modeling and PSA quantification and automation easier and faster. (author). 8 refs

  7. Development of the SKI Handbook for reviewing PSA after the review of the of a PSA level 2 study; Utveckling av SKIs Tillsynshandbok foer PSA utifraan granskningen av en PSA Nivaa-2 studie

    Energy Technology Data Exchange (ETDEWEB)

    Lindholm, Ilona; Sairanen, Risto [VTT Processes, Helsinki (Finland)

    2003-02-01

    A review of the Oskarshamn 2 Level 2 PSA has been conducted by VTT Processes. One objective of the review was validation and development of Tillsynshandbok PSA applying it to Oskarshamn 2 PSA Level 2 study. The review was based on the PSA Level 2 documentation: the main report, the supporting reports on containment success criteria and release calculations with the MAAP4 code, and five phenomenological reports for selected specific questions. The main result of the phenomenological analyses is that none of the phenomena considered contributes to the conditional failure probability of the Oskarshamn 2 containment in severe accidents. The project was conducted as a set of separate studies and the project quality assurance has also focused on one part at the time. As such, the quality assurance is adequate. A high level QA ensuring that all separate studies and analysis steps use same assumptions seems to be missing. Results from the phenomenology reports are not always transferred to accident analyses and vice versa. There is no specific discussion of uncertainty or sensitivity analyses. In general, the number of sensitivity analyses could be larger. Such should have been provided for sequences or phenomena that could result in early or unmitigated release. Examples are pressure vessel failure at high pressure, the effect of larger hydrogen production, and the key assumptions used for steam explosion and direct containment heating. Suggestions for additional sensitivity studies have been given in discussion of phenomenological reports. The project documentation is generally good. Missing information is usually associated with transfer of results from one study to another. It can be assumed that the information exists also in this cases but has not been documented in the reports above. Documentation of the containment event trees and the assumptions used for them could be more detailed, maybe similar to the approach used in the Appendix of this report. More effort

  8. Methodologies for uncertainty analysis in the level 2 PSA and their implementation procedures

    International Nuclear Information System (INIS)

    Ahn, Kwang Il; Yang, Joon Eun; Kim, Dong Ha

    2002-04-01

    Main purpose of this report to present standardized methodologies for uncertainty analysis in the Level 2 Probabilistic Safety Assessment (PSA) and their implementation procedures, based on results obtained through a critical review of the existing methodologies for the analysis of uncertainties employed in the Level 2 PSA, especially Accident Progression Event Tree (APET). Uncertainties employed in the Level 2 PSA, quantitative expressions of overall knowledge of analysts' and experts' participating in the probabilistic quantification process of phenomenological accident progressions ranging from core melt to containment failure, their numerical values are directly related to the degree of confidence that the analyst has that a given phenomenological event or accident process will or will not occur, or analyst's subjective probabilities of occurrence. These results that are obtained from Level 2 PSA uncertainty analysis, become an essential contributor to the plant risk, in addition to the Level 1 PSA and Level 3 PSA uncertainties. Uncertainty analysis methodologies and their implementation procedures presented in this report was prepared based on the following criteria: 'uncertainty quantification process must be logical, scrutable, complete, consistent and in an appropriate level of detail, as mandated by the Level 2 PSA objectives'. For the aforementioned purpose, this report deals mainly with (1) summary of general or Level 2 PSA specific uncertainty analysis methodologies, (2) selection of phenomenological branch events for uncertainty analysis in the APET, methodology for quantification of APET uncertainty inputs and its implementation procedure, (3) statistical propagation of uncertainty inputs through APET and its implementation procedure, and (4) formal procedure for quantification of APET uncertainties and source term categories (STCs) through the Level 2 PSA quantification codes

  9. Proteolytic Activity of Prostate-Specific Antigen (PSA) towards Protein Substrates and Effect of Peptides Stimulating PSA Activity

    Science.gov (United States)

    Mattsson, Johanna M.; Ravela, Suvi; Hekim, Can; Jonsson, Magnus; Malm, Johan; Närvänen, Ale; Stenman, Ulf-Håkan; Koistinen, Hannu

    2014-01-01

    Prostate-specific antigen (PSA or kallikrein-related peptidase-3, KLK3) exerts chymotrypsin-like proteolytic activity. The main biological function of PSA is the liquefaction of the clot formed after ejaculation by cleavage of semenogelins I and II in seminal fluid. PSA also cleaves several other substrates, which may explain its putative functions in prostate cancer and its antiangiogenic activity. We compared the proteolytic efficiency of PSA towards several protein and peptide substrates and studied the effect of peptides stimulating the activity of PSA with these substrates. An endothelial cell tube formation model was used to analyze the effect of PSA-degraded protein fragments on angiogenesis. We showed that PSA degrades semenogelins I and II much more efficiently than other previously identified protein substrates, e.g., fibronectin, galectin-3 and IGFBP-3. We identified nidogen-1 as a new substrate for PSA. Peptides B2 and C4 that stimulate the activity of PSA towards small peptide substrates also enhanced the proteolytic activity of PSA towards protein substrates. Nidogen-1, galectin-3 or their fragments produced by PSA did not have any effect on endothelial cell tube formation. Although PSA cleaves several other protein substrates, in addition to semenogelins, the physiological importance of this activity remains speculative. The PSA levels in prostate are very high, but several other highly active proteases, such as hK2 and trypsin, are also expressed in the prostate and may cleave protein substrates that are weakly cleaved by PSA. PMID:25237904

  10. Computer code MLCOSP for multiple-correlation and spectrum analysis with a hybrid computer

    International Nuclear Information System (INIS)

    Oguma, Ritsuo; Fujii, Yoshio; Usui, Hozumi; Watanabe, Koichi

    1975-10-01

    Usage of the computer code MLCOSP(Multiple Correlation and Spectrum) developed is described for a hybrid computer installed in JAERI Functions of the hybrid computer and its terminal devices are utilized ingeniously in the code to reduce complexity of the data handling which occurrs in analysis of the multivariable experimental data and to perform the analysis in perspective. Features of the code are as follows; Experimental data can be fed to the digital computer through the analog part of the hybrid computer by connecting with a data recorder. The computed results are displayed in figures, and hardcopies are taken when necessary. Series-messages to the code are shown on the terminal, so man-machine communication is possible. And further the data can be put in through a keyboard, so case study according to the results of analysis is possible. (auth.)

  11. Research on the improvement of nuclear safety -Development of level 2 PSA technology-

    International Nuclear Information System (INIS)

    Jin, Yung Hoh; Park, Soo Yong; Kim, Si Dal; Song, Yong Man; An, Kwang Il

    1995-07-01

    The objective of this project is the development of the computer code system for level 2 probabilistic safety assessment (PSA) of nuclear power plants. The scope of the project can be divided into three areas. The first area is to develop the computer code (CONPAS) which can quantify the accident progression event trees. CONPAS beta version has been developed this year and it is comprised of two modules: (1) EDITOR for generating the event tree logic diagrams and (2) QUANTIFICATION for event tree quantification and for additional use of the calculated results. Comparing with the existing computer code, the present code provides a flexible code reusability and user interface, convenient edition of logic diagram, data operation, and systematic quantification of the results. The methodology development of containment structural analysis is the second area. Over twenty large dry PWR containments, the database for containment failure mode and pressure has been constructed and the simplified fragility model has been proposed to calculate the containment failure probability. They will be used as an important input not only in the containment analysis but also in the source term analysis. The last one is to develop the source term analysis methodology which will be used to characterize the source term release for various accidents. One generic parametric equation for PWR and BWR has been composed and parametric database of 6 nuclear plants (4 PWR plants and 2 BWR plants) has been established whose characteristics is then analyzed through the comparison of parameter and data difference among plants. In addition, the characteristics of parameters themselves have been also investigated and the complemental idea of the parametric data base has been briefly suggested. 50 figs, 43 tabs, 50 refs. (Author)

  12. Research on the improvement of nuclear safety -Development of level 2 PSA technology-

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Yung Hoh; Park, Soo Yong; Kim, Si Dal; Song, Yong Man; An, Kwang Il [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-07-01

    The objective of this project is the development of the computer code system for level 2 probabilistic safety assessment (PSA) of nuclear power plants. The scope of the project can be divided into three areas. The first area is to develop the computer code (CONPAS) which can quantify the accident progression event trees. CONPAS beta version has been developed this year and it is comprised of two modules: (1) EDITOR for generating the event tree logic diagrams and (2) QUANTIFICATION for event tree quantification and for additional use of the calculated results. Comparing with the existing computer code, the present code provides a flexible code reusability and user interface, convenient edition of logic diagram, data operation, and systematic quantification of the results. The methodology development of containment structural analysis is the second area. Over twenty large dry PWR containments, the database for containment failure mode and pressure has been constructed and the simplified fragility model has been proposed to calculate the containment failure probability. They will be used as an important input not only in the containment analysis but also in the source term analysis. The last one is to develop the source term analysis methodology which will be used to characterize the source term release for various accidents. One generic parametric equation for PWR and BWR has been composed and parametric database of 6 nuclear plants (4 PWR plants and 2 BWR plants) has been established whose characteristics is then analyzed through the comparison of parameter and data difference among plants. In addition, the characteristics of parameters themselves have been also investigated and the complemental idea of the parametric data base has been briefly suggested. 50 figs, 43 tabs, 50 refs. (Author).

  13. Turbo Pascal Computer Code for PIXE Analysis

    International Nuclear Information System (INIS)

    Darsono

    2002-01-01

    To optimal utilization of the 150 kV ion accelerator facilities and to govern the analysis technique using ion accelerator, the research and development of low energy PIXE technology has been done. The R and D for hardware of the low energy PIXE installation in P3TM have been carried on since year 2000. To support the R and D of PIXE accelerator facilities in harmonize with the R and D of the PIXE hardware, the development of PIXE software for analysis is also needed. The development of database of PIXE software for analysis using turbo Pascal computer code is reported in this paper. This computer code computes the ionization cross-section, the fluorescence yield, and the stopping power of elements also it computes the coefficient attenuation of X- rays energy. The computer code is named PIXEDASIS and it is part of big computer code planed for PIXE analysis that will be constructed in the near future. PIXEDASIS is designed to be communicative with the user. It has the input from the keyboard. The output shows in the PC monitor, which also can be printed. The performance test of the PIXEDASIS shows that it can be operated well and it can provide data agreement with data form other literatures. (author)

  14. Users guide for NRC145-2 accident assessment computer code

    International Nuclear Information System (INIS)

    Pendergast, M.M.

    1982-08-01

    An accident assessment computer code has been developed for use at the Savannah River Plant. This computer code is based upon NRC Regulatory Guide 1.145 which provides guidence for accident assessements for power reactors. The code contains many options so that the user may utilize the code for many different assessments. For example the code can be used for non-nuclear assessments such as Sulpher Dioxide which may be required by the EPA. A discription of the code is contained in DP-1646. This document is a compilation of step-by-step instructions on how to use the code on the SRP IBM 3308 computer. This document consists of a number of tables which contain copies of computer listings. Some of the computer listings are copies of input; other listings give examples of computer output

  15. SHEAT: a computer code for probabilistic seismic hazard analysis, user's manual

    International Nuclear Information System (INIS)

    Ebisawa, Katsumi; Kondo, Masaaki; Abe, Kiyoharu; Tanaka, Toshiaki; Takani, Michio.

    1994-08-01

    The SHEAT code developed at Japan Atomic Energy Research Institute is for probabilistic seismic hazard analysis which is one of the tasks needed for seismic Probabilistic Safety Assessment (PSA) of a nuclear power plant. Seismic hazard is defined as an annual exceedance frequency of occurrence of earthquake ground motions at various levels of intensity at a given site. With the SHEAT code, seismic hazard is calculated by the following two steps: (1) Modeling of earthquake generation around a site. Future earthquake generation (locations, magnitudes and frequencies of postulated earthquakes) is modelled based on the historical earthquake records, active fault data and expert judgement. (2) Calculation of probabilistic seismic hazard at the site. An earthquake ground motion is calculated for each postulated earthquake using an attenuation model taking into account its standard deviation. Then the seismic hazard at the site is calculated by summing the frequencies of ground motions by all the earthquakes. This document is the user's manual of the SHEAT code. It includes: (1) Outlines of the code, which include overall concept, logical process, code structure, data file used and special characteristics of the code, (2) Functions of subprograms and analytical models in them, (3) Guidance of input and output data, and (4) Sample run results. The code has widely been used at JAERI to analyze seismic hazard at various nuclear power plant sites in japan. (author)

  16. Proteolytic activity of prostate-specific antigen (PSA towards protein substrates and effect of peptides stimulating PSA activity.

    Directory of Open Access Journals (Sweden)

    Johanna M Mattsson

    Full Text Available Prostate-specific antigen (PSA or kallikrein-related peptidase-3, KLK3 exerts chymotrypsin-like proteolytic activity. The main biological function of PSA is the liquefaction of the clot formed after ejaculation by cleavage of semenogelins I and II in seminal fluid. PSA also cleaves several other substrates, which may explain its putative functions in prostate cancer and its antiangiogenic activity. We compared the proteolytic efficiency of PSA towards several protein and peptide substrates and studied the effect of peptides stimulating the activity of PSA with these substrates. An endothelial cell tube formation model was used to analyze the effect of PSA-degraded protein fragments on angiogenesis. We showed that PSA degrades semenogelins I and II much more efficiently than other previously identified protein substrates, e.g., fibronectin, galectin-3 and IGFBP-3. We identified nidogen-1 as a new substrate for PSA. Peptides B2 and C4 that stimulate the activity of PSA towards small peptide substrates also enhanced the proteolytic activity of PSA towards protein substrates. Nidogen-1, galectin-3 or their fragments produced by PSA did not have any effect on endothelial cell tube formation. Although PSA cleaves several other protein substrates, in addition to semenogelins, the physiological importance of this activity remains speculative. The PSA levels in prostate are very high, but several other highly active proteases, such as hK2 and trypsin, are also expressed in the prostate and may cleave protein substrates that are weakly cleaved by PSA.

  17. Mutations in the prostate specific antigen (PSA/KLK3) correlate with male infertility.

    Science.gov (United States)

    Gupta, Nishi; Sudhakar, Digumarthi V S; Gangwar, Pravin Kumar; Sankhwar, Satya Narayan; Gupta, Nalini J; Chakraborty, Baidyanath; Thangaraj, Kumarasamy; Gupta, Gopal; Rajender, Singh

    2017-09-11

    Prostate specific antigen (PSA/KLK3) is known to be the chief executor of the fragmentation of semenogelins, dissolution of semen coagulum, thereby releasing sperm for active motility. Recent research has found that semenogelins also play significant roles in sperm fertility by affecting hyaluronidase activity, capacitation and motility, thereby making PSA important for sperm fertility beyond simple semen liquefaction. PSA level in semen has been shown to correlate with sperm motility, suggesting that PSA level/activity can affect fertility. However, no study investigating the genetic variations in the KLK3/PSA gene in male fertility has been undertaken. We analyzed the complete coding region of the KLK3 gene in ethnically matched 875 infertile and 290 fertile men to find if genetic variations in KLK3 correlate with infertility. Interestingly, this study identified 28 substitutions, of which 8 were novel (not available in public databases). Statistical comparison of the genotype frequencies showed that five SNPs, rs266881 (OR = 2.92, P  C, was more freuqent in the control group, showing protective association. Our findings suggest that polymorphisms in the KLK3 gene correlate with infertility risk.

  18. Evaluation of the SCANAIR Computer Code

    International Nuclear Information System (INIS)

    Jernkvist, Lars Olof; Massih, Ali

    2001-11-01

    The SCANAIR computer code, version 3.2, has been evaluated from the standpoint of its capability to analyze, simulate and predict nuclear fuel behavior during severe power transients. SCANAIR calculates the thermal and mechanical behavior of a pressurized water reactor (PWR) fuel rod during a postulated reactivity initiated accident (RIA), and our evaluation indicates that SCANAIR is a state of the art computational tool for this purpose. Our evaluation starts by reviewing the basic theoretical models in SCANAIR, namely the governing equations for heat transfer, the mechanical response of fuel and clad, and the fission gas release behavior. The numerical methods used to solve the governing equations are briefly reviewed, and the range of applicability of the models and their limitations are discussed and illustrated with examples. Next, the main features of the SCANAIR user interface are delineated. The code requires an extensive amount of input data, in order to define burnup-dependent initial conditions to the simulated RIA. These data must be provided in a special format by a thermal-mechanical fuel rod analysis code. The user also has to supply the transient power history under RIA as input, which requires a code for neutronics calculation. The programming structure and documentation of the code are also addressed in our evaluation. SCANAIR is programmed in Fortran-77, and makes use of several general Fortran-77 libraries for handling input/output, data storage and graphical presentation of computed results. The documentation of SCANAIR and its helping libraries is generally of good quality. A drawback with SCANAIR in its present form, is that the code and its pre- and post-processors are tied to computers running the Unix or Linux operating systems. As part of our evaluation, we have performed a large number of computations with SCANAIR, some of which are documented in this report. The computations presented here include a hypothetical RIA in a high

  19. Computer codes used in particle accelerator design: First edition

    International Nuclear Information System (INIS)

    1987-01-01

    This paper contains a listing of more than 150 programs that have been used in the design and analysis of accelerators. Given on each citation are person to contact, classification of the computer code, publications describing the code, computer and language runned on, and a short description of the code. Codes are indexed by subject, person to contact, and code acronym

  20. MISER-I: a computer code for JOYO fuel management

    International Nuclear Information System (INIS)

    Yamashita, Yoshioki

    1976-06-01

    A computer code ''MISER-I'' is for a nuclear fuel management of Japan Experimental Fast Breeder Reactor JOYO. The nuclear fuel management in JOYO can be regarded as a fuel assembly management because a handling unit of fuel in JOYO plant is a fuel subassembly (core and blanket subassembly), and so the recording of material balance in computer code is made with each subassembly. The input information into computer code is given with each subassembly for a transfer operation, or with one reactor cycle and every one month for a burn-up in reactor core. The output information of MISER-I code is the fuel assembly storage record, fuel storage weight record in each material balance subarea at any specified day, and fuel subassembly transfer history record. Change of nuclear fuel composition and weight due to a burn-up is calculated with JOYO-Monitoring Code by off-line computation system. MISER-I code is written in FORTRAN-IV language for FACOM 230-48 computer. (auth.)

  1. Prostate-Specific Antigen (PSA) Test

    Science.gov (United States)

    ... Cancer Prostate Cancer Screening Research Prostate-Specific Antigen (PSA) Test On This Page What is the PSA ... parts of the body before being detected. The PSA test may give false-positive or false-negative ...

  2. PSA Level 2:Scope And Method Of PSA Level 2 For Nuclear Power Plant

    International Nuclear Information System (INIS)

    Widodo, Surip; Antariksawan, Anhar R.

    2001-01-01

    A study of scope and method of PSA Level 2 had been conducted. The background of the study is the need to gain the capability to well perform PSA Level 2 for nuclear facilities. This study is a literature survey. The scope of PSA Level 2 consists of generating plant damage states, accident progression analysis, and grouping source terms. Concerning accident progression analysis, several methods are used, among others event tree method, named accident progression event tree (APET) or containment event tree (CET), and fault tree method. The end result of PSA Level 2 is release end states which is grouped into release bins. The results will be used for PSA Level 3

  3. Hamor-2: a computer code for LWR inventory calculation

    International Nuclear Information System (INIS)

    Guimaraes, L.N.F.; Marzo, M.A.S.

    1985-01-01

    A method for calculating the accuracy inventory of LWR reactors is presented. This method uses the Hamor-2 computer code. Hamor-2 is obtained from the coupling of two other computer codes Hammer-Techion and Origen-2 for testing Hamor-2, its results were compared to concentration values measured from activides of two PWR reactors; Kernkraftwerk Obrighein (KWO) and H.B. Robinson (HBR). These actinides are U 235 , U 236 , U 238 , Pu 239 , Pu 241 and PU 242 . The computer code Hammor-2 shows better results than the computer code Origem-2, when both are compared with experimental results. (E.G.) [pt

  4. The development of integrated safety assessment technology

    International Nuclear Information System (INIS)

    Yoo, Keon Joong; Park, Chang Kyu; Kim, Tae Un; Han, Sang Hoon; Yang, Joon Eon; Lim, Tae Jin; Han, Jae Joo; Je, Moo Seong; An, Kwang Il; Kim, Shi Dal; Jeong, Jong Tae; Jeong, Kwang Seop; Jin, Yeong Ho; Kim, Dong Ha; Kim, Kil Yoo; Cho, Yeong Kyoon; Jeong, Won Dae; Jang, Seung Cheol; Choi, Yeong; Park, Soo Yong; Seong, Tae Yong; Song, Yong Man; Kang, Dae Il; Park, Jin Hee; Jang, Seon Joo; Hwang, Mi Jeong; Choi, Seon Yeong

    1993-05-01

    For the purpose of developing the integrated PSA methodology and computer codes, Level-1 and Level-2 PSA methodology and tools were reviewed and improved. The Level-1 PSA computer code package KIRAP was improved and released by the name of KIRAP Release 2.0 Several Human reliability analysis and common cause failure analysis methods was reviewed and compared. For the development of Level-2 PSA computer code, several level-1 and Level-2 interface methods and containment event tree development methods were reviewed and compared. And the new technology such as artificial intelligence was reviewed if the technology can be applied to the development of PSA methodology.(Author)

  5. Qualification of calculation aids for PSA

    International Nuclear Information System (INIS)

    Goetz, K.; Hennigs, W.; Kirstein, B.M.; Reinhardt, C.

    1998-01-01

    In Germany Probabilistic Safety Analysis (PSA) are part of the evaluation of a nuclear power plants safety. The German PSA guide stipulates that the used software must enable a PSA according to the state of the art. This software must be qualified to assure that its features, mathematic methods and its performance enable a PSA like this. In this research work specifications and requirements are developed, which allow the testing of software. A procedure was developed to qualify PSA software according to the PSA guide and the experiences of users of PSA. Setting up a procedure, a tool for a systematic and uniform examination was crated. Additionally the options, mathematic fundamentals and performance of PSA-programs were analyzed. According to this all programs that were analyzed are capable to sovle their original task, that is the calculation of the safety of high available system based on high available components. Against that the requirements of modern PSA, e.g. to handle less available functions, HRA and fire analyses, based on the use of modern software and the implementation of new developments in the field of PSA are not supported adequately by all programs. (orig.) [de

  6. A study on the nuclear computer code maintenance and management system

    International Nuclear Information System (INIS)

    Kim, Yeon Seung; Huh, Young Hwan; Lee, Jong Bok; Choi, Young Gil; Suh, Soong Hyok; Kang, Byong Heon; Kim, Hee Kyung; Kim, Ko Ryeo; Park, Soo Jin

    1990-12-01

    According to current software development and quality assurance trends. It is necessary to develop computer code management system for nuclear programs. For this reason, the project started in 1987. Main objectives of the project are to establish a nuclear computer code management system, to secure software reliability, and to develop nuclear computer code packages. Contents of performing the project in this year were to operate and maintain computer code information system of KAERI computer codes, to develop application tool, AUTO-i, for solving the 1st and 2nd moments of inertia on polygon or circle, and to research nuclear computer code conversion between different machines. For better supporting the nuclear code availability and reliability, assistance from users who are using codes is required. Lastly, for easy reference about the codes information, we presented list of code names and information on the codes which were introduced or developed during this year. (Author)

  7. Computer and compiler effects on code results: status report

    International Nuclear Information System (INIS)

    1996-01-01

    Within the framework of the international effort on the assessment of computer codes, which are designed to describe the overall reactor coolant system (RCS) thermalhydraulic response, core damage progression, and fission product release and transport during severe accidents, there has been a continuous debate as to whether the code results are influenced by different code users or by different computers or compilers. The first aspect, the 'Code User Effect', has been investigated already. In this paper the other aspects will be discussed and proposals are given how to make large system codes insensitive to different computers and compilers. Hardware errors and memory problems are not considered in this report. The codes investigated herein are integrated code systems (e. g. ESTER, MELCOR) and thermalhydraulic system codes with extensions for severe accident simulation (e. g. SCDAP/RELAP, ICARE/CATHARE, ATHLET-CD), and codes to simulate fission product transport (e. g. TRAPMELT, SOPHAEROS). Since all of these codes are programmed in Fortran 77, the discussion herein is based on this programming language although some remarks are made about Fortran 90. Some observations about different code results by using different computers are reported and possible reasons for this unexpected behaviour are listed. Then methods are discussed how to avoid portability problems

  8. Generation of monoclonal antibodies against prostate specific antigen (PSA) for the detection of PSA and its purification

    International Nuclear Information System (INIS)

    Acevedo Castro, Boris Ernesto

    2012-01-01

    The prostate cancer in Cuba is a problem of health (2672 diagnosed cases and 2769 deaths in 2007). Various diagnostic methods have been implemented for the detection and management of this disease, emphasizing among them (PSA) prostate-specific antigen serological determination. At this work was generated and characterized a panel of 11 antibodies (AcMs) monoclonal IgG1 detected with high affinity described major epitopes of the PSA, both in solution and attached to the test plate. From the panel obtained AcMs was the standardization of an essay type ELISA for the detection of serum total PSA (associated and free) equimolar, based on antibody monoclonal CB-PSA.4 in the coating and the CB-PSA.9 coupled with biotin as liner, with a detection limit of 0.15 ng/mL. Similarly, standardized system for detection in serum free PSA, based on the AcMs CB-PSA.4 (coating) and CB-PSA.2 coupled with biotin (liner), with a detection limit of 0.5 ng/mL. Finally, with the purpose of using PSA as standard in trials type ELISA, developed a simple method of inmunopurificación based on the AcM, CB-PSA.2, which was obtained the PSA with a purity exceeding 90%. Immunoassay Centre on the basis of the AcMs panel and the results of this study, developed and recorded two diagnostic systems for the detection of PSA in human serum. (author)

  9. Model engineering in a modular PSA

    International Nuclear Information System (INIS)

    Friedlhuber, Thomas

    2014-01-01

    For the purpose of PSA (Probabilistic Safety Analysis) for complex industrial systems, often PSA models in the form of fault and event trees are developed to model the risk of unwanted situations (hazards). While the recent decades, PSA models have gained high acceptance and have been developed massively. This lead to an increase in model sizes and complexity. Today, PSA models are often difficult to understand and maintain. This manuscript presents the concept of a modular PSA. A modular PSA tries to cope with the increased complexity by the techniques of modularization and instantiation. Modularization targets to treat a model by smaller pieces (the 'modules') to regain control over models. Instantiation aims to configure a generic model to different contexts. Both try to reduce model complexity. A modular PSA proposes new functionality to manage PSA models. Current model management is rather limited and not efficient. This manuscript shows new methods to manage the evolutions (versions) and deviations (variants) of PSA models in a modular PSA. The concepts of version and variant management are presented in this thesis. In this context, a model comparison and fusion of PSA models is precised. Model comparison provides important feedback to model engineers and model fusion kind of combines the work from different model engineers (concurrent model engineering). Apart from model management, methods to understand the content of PSA models are presented. The methods focus to highlight the dependencies between modules rather than their contents. Dependencies are automatically derived from a model structure. They express relations between model objects (for example a fault tree may have dependencies to basic events). To visualize those dependencies (for example in form of a model cartography) can constitute a crucial aid to model engineers for understanding complex interrelations in PSA models. Within the scope of this thesis, a software named 'Andromeda' has been

  10. HUDU: The Hanford Unified Dose Utility computer code

    International Nuclear Information System (INIS)

    Scherpelz, R.I.

    1991-02-01

    The Hanford Unified Dose Utility (HUDU) computer program was developed to provide rapid initial assessment of radiological emergency situations. The HUDU code uses a straight-line Gaussian atmospheric dispersion model to estimate the transport of radionuclides released from an accident site. For dose points on the plume centerline, it calculates internal doses due to inhalation and external doses due to exposure to the plume. The program incorporates a number of features unique to the Hanford Site (operated by the US Department of Energy), including a library of source terms derived from various facilities' safety analysis reports. The HUDU code was designed to run on an IBM-PC or compatible personal computer. The user interface was designed for fast and easy operation with minimal user training. The theoretical basis and mathematical models used in the HUDU computer code are described, as are the computer code itself and the data libraries used. Detailed instructions for operating the code are also included. Appendices to the report contain descriptions of the program modules, listings of HUDU's data library, and descriptions of the verification tests that were run as part of the code development. 14 refs., 19 figs., 2 tabs

  11. Development of a PSA information management system

    International Nuclear Information System (INIS)

    Ho, Seok; Dong Kyu, Kim; Sun Koo, Kang

    2007-01-01

    In general, Probabilistic Safety Agreement (PSA) is a very complicated work that uses and generates a lot of resources such as reports, procedures, drawings, assumptions, calculation sheets, PSA model, and so on. In many PSAs, however, the data, materials and knowledge considered and generated during performing PSA are scattered in many documents so that overall structure of PSA and information relationship between documents and models cannot easily be understood. To organize and manage all documents related to PSA, to capture knowledge of analysts, and finally to improve the quality of PSA, a PSA information management system (PIMS) was developed. The PIMS can manage all the documents of a PSA in a database and connect the causal relation between one information to another in the scattered documents via link. The PIMS can manage all the assumptions and technical basis used in PSA, and it can keep the record of the design changes the revision of PSA model. It can also control the review results of PSA models. The link of the PIMS can explicitly describe and reveal the expertise of the PSA analysts, and it enables the users to capture the knowledge and to understand the structure and contents of a PSA with ease. We are planning to apply the PIMS to the PSA of Shin Kori Units 1 and 2 as feasibility study and then to all the PSAs of the nuclear power plants in Korea. The PIMS is expected to contribute to enhancing the quality and confidence of PSA and reducing the efforts and costs of maintenance and update of PSA. (authors)

  12. Development of a PSA information management system

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Seok; Dong Kyu, Kim; Sun Koo, Kang [Korea Power Engineering Company, Inc (Korea, Republic of)

    2007-07-01

    In general, Probabilistic Safety Agreement (PSA) is a very complicated work that uses and generates a lot of resources such as reports, procedures, drawings, assumptions, calculation sheets, PSA model, and so on. In many PSAs, however, the data, materials and knowledge considered and generated during performing PSA are scattered in many documents so that overall structure of PSA and information relationship between documents and models cannot easily be understood. To organize and manage all documents related to PSA, to capture knowledge of analysts, and finally to improve the quality of PSA, a PSA information management system (PIMS) was developed. The PIMS can manage all the documents of a PSA in a database and connect the causal relation between one information to another in the scattered documents via link. The PIMS can manage all the assumptions and technical basis used in PSA, and it can keep the record of the design changes the revision of PSA model. It can also control the review results of PSA models. The link of the PIMS can explicitly describe and reveal the expertise of the PSA analysts, and it enables the users to capture the knowledge and to understand the structure and contents of a PSA with ease. We are planning to apply the PIMS to the PSA of Shin Kori Units 1 and 2 as feasibility study and then to all the PSAs of the nuclear power plants in Korea. The PIMS is expected to contribute to enhancing the quality and confidence of PSA and reducing the efforts and costs of maintenance and update of PSA. (authors)

  13. Proceedings of the 10th Korea-Japan joint workshop on PSA. For Asian PSA network

    International Nuclear Information System (INIS)

    Yang, Joon-Eon; Homma, Toshimitsu

    2009-12-01

    The tenth Korea-Japan Joint Workshop on Probabilistic Safety Assessment (PSA) was held in the Jeju island of Korea, on May 18-20, 2009 organized by Korea Atomic Energy Research Institute (KAERI). The purpose of the workshop was to provide a forum for presentation and discussions on experiences and technical achievements related to PSA, risk-informed and performance-based approach, and other relevant issues in both countries. Since the first Korea-Japan Joint Workshop on PSA started in 1992, the workshops have provided an important and timely opportunity for exchange and discussion of the relevant information to all PSA practitioners and users of risk information in the industry, research, academia and regulatory arena. This was the tenth anniversary of the Joint Workshop with the main theme of 'For Asian PSA Network' and participants included those from China, Taiwan and the United States of America besides Korea and Japan. Two keynote speeches were presented by the former chairmen of this workshop, Prof. Chang-Sun Kang of Seoul National University and Prof. emeritus Shunsuke Kondo of Tokyo University. We had two special lectures, 70 papers presented by experts at 10 technical sessions related PSA, the special session on the status of PSA in Korea, Japan, China and Taiwan and panel discussion on their cooperation in PSA. This report provides the summary of each session, and all the presentation materials presented in the 10th Korea-Japan Joint Workshop on PSA. (author)

  14. Nonuniform code concatenation for universal fault-tolerant quantum computing

    Science.gov (United States)

    Nikahd, Eesa; Sedighi, Mehdi; Saheb Zamani, Morteza

    2017-09-01

    Using transversal gates is a straightforward and efficient technique for fault-tolerant quantum computing. Since transversal gates alone cannot be computationally universal, they must be combined with other approaches such as magic state distillation, code switching, or code concatenation to achieve universality. In this paper we propose an alternative approach for universal fault-tolerant quantum computing, mainly based on the code concatenation approach proposed in [T. Jochym-O'Connor and R. Laflamme, Phys. Rev. Lett. 112, 010505 (2014), 10.1103/PhysRevLett.112.010505], but in a nonuniform fashion. The proposed approach is described based on nonuniform concatenation of the 7-qubit Steane code with the 15-qubit Reed-Muller code, as well as the 5-qubit code with the 15-qubit Reed-Muller code, which lead to two 49-qubit and 47-qubit codes, respectively. These codes can correct any arbitrary single physical error with the ability to perform a universal set of fault-tolerant gates, without using magic state distillation.

  15. Computer codes for ventilation in nuclear facilities

    International Nuclear Information System (INIS)

    Mulcey, P.

    1987-01-01

    In this paper the authors present some computer codes, developed in the last years, for ventilation and radioprotection. These codes are used for safety analysis in the conception, exploitation and dismantlement of nuclear facilities. The authors present particularly: DACC1 code used for aerosol deposit in sampling circuit of radiation monitors; PIAF code used for modelization of complex ventilation system; CLIMAT 6 code used for optimization of air conditioning system [fr

  16. International survey of living PSA and safety indicators

    International Nuclear Information System (INIS)

    Holmberg, J.; Laakso, K.; Lehtinen, E.; Bjoere, S.

    1992-01-01

    The report contains an international overview of applications of living probabilistic assessment and development of operational safety indicators. Features of an ideal living PSA tool are summarized as well as a limited survey of code systems for managing a living probabilistic safety assessment (living PSA) is included. The international survey is used as an input for planning and performance of related tasks within the nordic NKS/SIK-1 project conducted in 1990-93. The research notes are distributed to the Nordic organizations involved or interested in the subject. The report includes an overview and conclusions from technical reports and articles available and presentations and discussions related to development and use of above methods for the evaluation and management of the operational safety of nuclear power plants. A large part of this material is based on material collected and discussed in connection to international specialist meetings relating to the subject

  17. Development of a PSA information database system

    International Nuclear Information System (INIS)

    Kim, Seung Hwan

    2005-01-01

    The need to develop the PSA information database for performing a PSA has been growing rapidly. For example, performing a PSA requires a lot of data to analyze, to evaluate the risk, to trace the process of results and to verify the results. PSA information database is a system that stores all PSA related information into the database and file system with cross links to jump to the physical documents whenever they are needed. Korea Atomic Energy Research Institute is developing a PSA information database system, AIMS (Advanced Information Management System for PSA). The objective is to integrate and computerize all the distributed information of a PSA into a system and to enhance the accessibility to PSA information for all PSA related activities. This paper describes how we implemented such a database centered application in the view of two areas, database design and data (document) service

  18. Automated uncertainty analysis methods in the FRAP computer codes

    International Nuclear Information System (INIS)

    Peck, S.O.

    1980-01-01

    A user oriented, automated uncertainty analysis capability has been incorporated in the Fuel Rod Analysis Program (FRAP) computer codes. The FRAP codes have been developed for the analysis of Light Water Reactor fuel rod behavior during steady state (FRAPCON) and transient (FRAP-T) conditions as part of the United States Nuclear Regulatory Commission's Water Reactor Safety Research Program. The objective of uncertainty analysis of these codes is to obtain estimates of the uncertainty in computed outputs of the codes is to obtain estimates of the uncertainty in computed outputs of the codes as a function of known uncertainties in input variables. This paper presents the methods used to generate an uncertainty analysis of a large computer code, discusses the assumptions that are made, and shows techniques for testing them. An uncertainty analysis of FRAP-T calculated fuel rod behavior during a hypothetical loss-of-coolant transient is presented as an example and carried through the discussion to illustrate the various concepts

  19. Study of nuclear computer code maintenance and management system

    International Nuclear Information System (INIS)

    Ryu, Chang Mo; Kim, Yeon Seung; Eom, Heung Seop; Lee, Jong Bok; Kim, Ho Joon; Choi, Young Gil; Kim, Ko Ryeo

    1989-01-01

    Software maintenance is one of the most important problems since late 1970's.We wish to develop a nuclear computer code system to maintenance and manage KAERI's nuclear software. As a part of this system, we have developed three code management programs for use on CYBER and PC systems. They are used in systematic management of computer code in KAERI. The first program is embodied on the CYBER system to rapidly provide information on nuclear codes to the users. The second and the third programs were embodied on the PC system for the code manager and for the management of data in korean language, respectively. In the requirement analysis, we defined each code, magnetic tape, manual and abstract information data. In the conceptual design, we designed retrieval, update, and output functions. In the implementation design, we described the technical considerations of database programs, utilities, and directions for the use of databases. As a result of this research, we compiled the status of nuclear computer codes which belonged KAERI until September, 1988. Thus, by using these three database programs, we could provide the nuclear computer code information to the users more rapidly. (Author)

  20. Implantation of FRAPCON-2 code in HB computer

    International Nuclear Information System (INIS)

    Silva, C.F. da.

    1987-05-01

    The modifications carried out for implanting FRAPCON-2 computer code in the HB DPS-T7 computer are presented. The FRAPCON-2 code calculates thermo-mechanical response during long period of burnup in stationary state for fuel rods of PWR type reactors. (M.C.K.)

  1. The use of living PSA for on-line risk management by plant operators

    International Nuclear Information System (INIS)

    Moir, Gordon R.

    2004-01-01

    The concept of Living Probabilistic Safety Assessment (LPSA) has existed for several years and reflects the desire to utilise the knowledge gained in producing PSAs for nuclear power plants. In most countries the regulator requires that PSA are performed on all new nuclear power plants in order to demonstrate that the design and operation of the plant will meet the required safety standards. In the past, having satisfied the regulator, these PSAs were then regarded as having served their purpose and 'put on the shelf'. In the course of time all plants undergo modification, operational procedures change and develop, and plant specific reliability data becomes available throughout the lifetime of the plant. The original plant specific PSA will therefore rapidly become outdated and need revision. The concept of LPSA is therefore to provide a vehicle for evaluating the effect of plant changes throughout the plant's lifetime. Within the framework of LPSA 'living' can mean anything from updating the PSA infrequently, e.g. as and when major design changes are implemented, to updating the PSA in real time as plant is made unavailable due to maintenance or failure. Constructing and analysing plant specific PSA takes man years of effort in analysing all safety related systems. The result is a very detailed model of the interactions between systems and how they can fail. In order to gain the maximum benefit from this extensive and detailed knowledge base. Nuclear Electric has been involved in the development of PSA codes which enable rapid assessment of PSA. The development of such a code, the Essential Systems Status Monitor (ESSM), has allowed interactive use of the PSA and has maximised the benefit of the knowledge held in the PSA to plan and manage low risk maintenance strategies. The paper describes how the emphasis in the development of the ESSM has been to provide the operator with an interactive LPSA facility to maximise the use and benefits of the original PSA model

  2. Clinical performance of serum [-2]proPSA derivatives, %p2PSA and PHI, in the detection and management of prostate cancer.

    Science.gov (United States)

    Huang, Ya-Qiang; Sun, Tong; Zhong, Wei-De; Wu, Chin-Lee

    2014-01-01

    Prostate-specific antigen (PSA) has been widely used as a serum marker for prostate cancer (PCa) screening or progression monitoring, which dramatically increased rate of early detection while significantly reduced PCa-specific mortality. However, a number of limitations of PSA have been noticed. Low specificity of PSA may lead to overtreatment in men who presenting with a total PSA (tPSA) level of PHI) and %p2PSA, which were defined as [(p2PSA/fPSA) × √ tPSA] and [(p2PSA/fPSA) × 100] respectively, have been suggested to be increased in PCa and can better distinguish PCa from benign prostatic diseases than tPSA or fPSA. We performed a systematic review of the available scientific evidences to evaluate the potentials of %p2PSA and PHI in clinical application. Mounting evidences suggested that both %p2PSA and PHI possess higher area under the ROC curve (AUC) and better specificity at a high sensitivity for PCa detection when compare with tPSA and %fPSA. It indicated that measurements of %p2PSA and PHI significantly improved the accuracy of PCa detection and diminished unnecessary biopsies. Furthermore, elevations of %p2PSA and PHI are related to more aggressive diseases. %p2PSA and PHI might be helpful in reducing overtreatment on indolent cases or assessing the progression of PCa in men who undergo active surveillance. Further studies are needed before being applied in routine clinical practice.

  3. Methodology for seismic PSA of NPPs

    International Nuclear Information System (INIS)

    Jirsa, P.

    1999-09-01

    A general methodology is outlined for seismic PSA (probabilistic safety assessment). The main objectives of seismic PSA include: description of the course of an event; understanding the most probable failure sequences; gaining insight into the overall probability of reactor core damage; identification of the main seismic risk contributors; identification of the range of peak ground accelerations contributing significantly to the plant risk; and comparison of the seismic risk with risks from other events. The results of seismic PSA are typically compared with those of internal PSA and of PSA of other external events. If the results of internal and external PSA are available, sensitivity studies and cost benefit analyses are performed prior to any decision regarding corrective actions. If the seismic PSA involves analysis of the containment, useful information can be gained regarding potential seismic damage of the containment. (P.A.)

  4. PSA applications. Good practices and documentation

    International Nuclear Information System (INIS)

    Dewailly, J.; Magne, L.

    1997-10-01

    In this paper, it is shown what the condensed documentation of the main strategic choices and technical assumptions related to a PSA could contain: how to select the internal and external initiating events, how the detail the plant configuration and the general organization of the plant and operating staff, how to highlight the assumptions related to physical models, etc. The proposals in this documentation are based on the R and D D's experience with PSA (construction of PSA models, use of PSA models for operation or maintenance, PSA tools). This document also presents different types of rules or recommendations related to PSA modelling for various applications involved in nuclear power plant operating. Finally, the paper stresses the main difficulties encountered (appropriate use of uncertainties, communication of PSA results to non-specialist users) and it also outlines some prospects for the future. (author)

  5. Computer code FIT

    International Nuclear Information System (INIS)

    Rohmann, D.; Koehler, T.

    1987-02-01

    This is a description of the computer code FIT, written in FORTRAN-77 for a PDP 11/34. FIT is an interactive program to decude position, width and intensity of lines of X-ray spectra (max. length of 4K channels). The lines (max. 30 lines per fit) may have Gauss- or Voigt-profile, as well as exponential tails. Spectrum and fit can be displayed on a Tektronix terminal. (orig.) [de

  6. [PSA interest and prostatitis: literature review].

    Science.gov (United States)

    Bruyère, F; Amine Lakmichi, M

    2013-12-01

    Prostatitis is easily diagnosed but sometimes associated with PSA measurement. An increased PSA in an asymptomatic patient may be associated with antibiotic use to eliminate the inflammatory part and to confirm prostate biopsy. It seems interesting to confirm or infirm these attitudes with a systematic review of the literature We performed a literature review using the words [prostatitis], [acute prostatitis], [prostate specific antigen], [PSA], in the MEDLINE, Pubmed and AMBASE database searching for articles in French or English published in the past 20 years. PSA is not always increased during an acute prostatitis episode. An increased PSA in an asymptomatic man does not seem to be systematically correlated to prostate inflammation. Analyzing the studies, it seems inaccurate to measure PSA value during a febrile urinary infection episode in men. Systematic use of antibiotic to decrease PSA and not performing prostate biopsy is not relevant and may induce resistance to antibiotic and doesn't induce a reduction risk of having prostate biopsy. PSA is unnecessary in case of febrile urinary tract infection in men. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  7. Living PSA issues in France on pressurized water reactors

    International Nuclear Information System (INIS)

    Dewailly, J.; Deriot, S.; Dubreuil Chambardel, A.; Francois, P.; Magne, L.

    1993-09-01

    Two Probabilistic Safety Assessments (PSAs) carried out in France on 900 and 1300 MWe Pressurized Water Reactor units ended in 1990. These PSAs determined the core damage frequency for all plant operating conditions ranging from cold shutdown for refuelling to full power operation. Since 1990, these PSAs have been used increasingly as tools for applications such as accident precursor analysis, risk-based Technical Specifications, and maintenance optimization. In turn, these applications are used to enhance the initial PSAs. The notion of a ''living'' PSA which can be used and updated is slowly taking form. The accident precursor analysis consists in applying PSA event trees to obtain quick information on the potential consequences of a precursor event and on the corresponding probabilities of occurrence. A feedback on PSAs is provided by comparing them with actual operating incidents. The computation of the allowed outage time during power operation, based on the computerized models of Probabilistic Safety Assessments, requires adjustments: calculation of hourly risk of core damage under different reactor conditions without equipment unavailabilities. The proposed method also turns out to be an aid in determining the safe shutdown condition and procedure. Furthermore, when introducing a sufficient level of detail, PSA reliability models make it possible to compute contributions and to perform sensitivity studies in order to highlight those components for which a maintenance effort should be made. From the experience acquired up to now, there was felt to be a strong need to create guidelines for using PSAs that would simplify their implementation by the experts in charge of determining Technical Specifications, of maintenance programs, etc. who are not generally specialists in PSAs. For this purpose, it is necessary to improve the intelligibility of the models made in order for them to be used and to offer user's guides adapted to each application. Documents

  8. Applicability of living PSA in NPP modernization

    International Nuclear Information System (INIS)

    Himanen, R.

    1999-01-01

    Recently the utility Teollisuuden Voima Oy (TVO) has modernized the Olkiluoto 1 and 2 nuclear units and increased the net electric power by 18 per cent. Level 2 PSA was performed during the modernization project and the living level 1 PSA was used to support the design of the plant modifications. The plant specific living PSA model was a powerful tool when evaluating modernization alternatives. Successive support of safety management with the PSA model requires, that both the utility and the Regulatory Body understand capability and limitations of the model in details. TVO has prepared an internal procedure that presents in detail the practices and responsibilities concerning living PSA. The procedure is based on general guidelines and requirements on probabilistic safety analysis of nuclear power plants in Finland, released by the Regulatory Body. Living PSA requires that also the procedure for the use of living PSA is living. The recently published USNRC Regulatory Guides on PSA will be taken into account in the next version of the TVO PSA procedure. The PSA Peer Review Certification Process is one way to evaluate the quality of PSA in general, but also to detect the weaknesses of the PSA. However, the Certification Process cover only limited scope of PSA omitting e.g. all other external events except internal floods. This paper gives an overview on the scope of living PSA for Olkiluoto 1 and 2, and presents some examples on the real use of PSA concerning the modernization of the plant. Definition of quantitative dependability requirements for renovated systems is possible, but on the other hand, proving of these targets is in some cases extremely difficult, because of lacking dependability data. The problems are mainly concerned in systems with of programmable logic control. (au)

  9. The percentage of prostate-specific antigen (PSA) isoform [-2]proPSA and the Prostate Health Index improve the diagnostic accuracy for clinically relevant prostate cancer at initial and repeat biopsy compared with total PSA and percentage free PSA in men aged ≤65 years.

    Science.gov (United States)

    Boegemann, Martin; Stephan, Carsten; Cammann, Henning; Vincendeau, Sébastien; Houlgatte, Alain; Jung, Klaus; Blanchet, Jean-Sebastien; Semjonow, Axel

    2016-01-01

    To prospectively test the diagnostic accuracy of the percentage of prostate specific antigen (PSA) isoform [-2]proPSA (%p2PSA) and the Prostate Health Index (PHI), and to determine their role for discrimination between significant and insignificant prostate cancer at initial and repeat prostate biopsy in men aged ≤65 years. The diagnostic performance of %p2PSA and PHI were evaluated in a multicentre study. In all, 769 men aged ≤65 years scheduled for initial or repeat prostate biopsy were recruited in four sites based on a total PSA (t-PSA) level of 1.6-8.0 ng/mL World Health Organization (WHO) calibrated (2-10 ng/mL Hybritech-calibrated). Serum samples were measured for the concentration of t-PSA, free PSA (f-PSA) and p2PSA with Beckman Coulter immunoassays on Access-2 or DxI800 instruments. PHI was calculated as (p2PSA/f-PSA × √t-PSA). Uni- and multivariable logistic regression models and an artificial neural network (ANN) were complemented by decision curve analysis (DCA). In univariate analysis %p2PSA and PHI were the best predictors of prostate cancer detection in all patients (area under the curve [AUC] 0.72 and 0.73, respectively), at initial (AUC 0.67 and 0.69) and repeat biopsy (AUC 0.74 and 0.74). t-PSA and %f-PSA performed less accurately for all patients (AUC 0.54 and 0.62). For detection of significant prostate cancer (based on Prostate Cancer Research International Active Surveillance [PRIAS] criteria) the %p2PSA and PHI equally demonstrated best performance (AUC 0.70 and 0.73) compared with t-PSA and %f-PSA (AUC 0.54 and 0.59). In multivariate analysis PHI we added to a base model of age, prostate volume, digital rectal examination, t-PSA and %f-PSA. PHI was strongest in predicting prostate cancer in all patients, at initial and repeat biopsy and for significant prostate cancer (AUC 0.73, 0.68, 0.78 and 0.72, respectively). In DCA for all patients the ANN showed the broadest threshold probability and best net benefit. PHI as single parameter

  10. Performance indicators at Embalse NPP: PSA and safety system indicators based on PSA models

    International Nuclear Information System (INIS)

    Fornero, D.A.

    2001-01-01

    Several indicators have been implemented at Embalse NPP. The objective was selecting some representative parameters to evaluate the performance of both the plant and the personnel activities, important for safety. A first set of indicators was defined in accordance with plant technical staff criteria. A complementary set of them was addressed later based on WANO guidance. This report presents the set of indicators used at Embalse NPP, centering the description to related to safety systems performance indicators (SSPI). Some considerations are done about the calculation methods, the need for aligning and updating their values following Embalse Probabilistic Safety Assessment (PSA) development, and some pros and cons of using the PSA model for getting systems indicators. Owing to the fact that PSA ownership by utilities is also a subject of the meeting, some characteristics of the organization of the PSA Project are described at the beginning of the report. At Embalse NPP a Level 1 PSA has been developed under the responsibility of its own plant and with an important contribution from the IAEA. PSA was developed at the site, conducting this to a study strongly interactive with the station staff. (author)

  11. APC: A New Code for Atmospheric Polarization Computations

    Science.gov (United States)

    Korkin, Sergey V.; Lyapustin, Alexei I.; Rozanov, Vladimir V.

    2014-01-01

    A new polarized radiative transfer code Atmospheric Polarization Computations (APC) is described. The code is based on separation of the diffuse light field into anisotropic and smooth (regular) parts. The anisotropic part is computed analytically. The smooth regular part is computed numerically using the discrete ordinates method. Vertical stratification of the atmosphere, common types of bidirectional surface reflection and scattering by spherical particles or spheroids are included. A particular consideration is given to computation of the bidirectional polarization distribution function (BPDF) of the waved ocean surface.

  12. Quantum computing with Majorana fermion codes

    Science.gov (United States)

    Litinski, Daniel; von Oppen, Felix

    2018-05-01

    We establish a unified framework for Majorana-based fault-tolerant quantum computation with Majorana surface codes and Majorana color codes. All logical Clifford gates are implemented with zero-time overhead. This is done by introducing a protocol for Pauli product measurements with tetrons and hexons which only requires local 4-Majorana parity measurements. An analogous protocol is used in the fault-tolerant setting, where tetrons and hexons are replaced by Majorana surface code patches, and parity measurements are replaced by lattice surgery, still only requiring local few-Majorana parity measurements. To this end, we discuss twist defects in Majorana fermion surface codes and adapt the technique of twist-based lattice surgery to fermionic codes. Moreover, we propose a family of codes that we refer to as Majorana color codes, which are obtained by concatenating Majorana surface codes with small Majorana fermion codes. Majorana surface and color codes can be used to decrease the space overhead and stabilizer weight compared to their bosonic counterparts.

  13. Towards a PSA harmonization French-Belgian comparison of the level 1 PSA for two similar PWR types

    International Nuclear Information System (INIS)

    Dupuy, P.; Corenwinder, F.; Lanore, J.M.; Gryffroy, D.; Gelder, P. de; Hulsmans, M.

    2002-06-01

    In the framework of the cooperation between French and Belgian regulatory authorities, a PSA (Probabilistic Safety Assessment) comparison exercise has been carried out for several years. This comparison deals with two PSA level 1 studies for internal events, performed for both power and shutdown states: the French PSA of the 900 MWe-series PWR, and the Belgian PSA of the Tihange 1 PWR, which both concern PWRs with a similar Framatome design. The purpose of this paper is to describe the PSA comparison methodology and to present, in a qualitative way, an overview of the insights obtained up to now. It also shows that such an 'a posteriori' benchmark exercise turns out to be a step towards PSA harmonization, and gives more confidence in the results of plant specific PSA when used for applications like precursor analysis or evaluations of importance to safety. (authors)

  14. Two-dimensional color-code quantum computation

    International Nuclear Information System (INIS)

    Fowler, Austin G.

    2011-01-01

    We describe in detail how to perform universal fault-tolerant quantum computation on a two-dimensional color code, making use of only nearest neighbor interactions. Three defects (holes) in the code are used to represent logical qubits. Triple-defect logical qubits are deformed into isolated triangular sections of color code to enable transversal implementation of all single logical qubit Clifford group gates. Controlled-NOT (CNOT) is implemented between pairs of triple-defect logical qubits via braiding.

  15. Status and use of PSA in Sweden

    International Nuclear Information System (INIS)

    Knochenhauer, M.

    1996-05-01

    The performance and use of PSA:s in Sweden goes back about two decades. During all of this time, the field of PSA has been developing intensively, both internationally and within Sweden. The latest years have been characterised by an increased use of PSA models and results, and by major extensions of existing PSA models. The aim of this document is to describe PSA in Sweden with respect to development, scope and maturity, as well as to the contents of the analyses and the use of results. PSA activities will be described from the point of view of both the authorities and the utilities. The report gives an overview of the development within the area of PSA in Sweden both its history and current trends. The aim has been to include a reasonable amount of detail, both on the methods and results in PSA:s performed and on the numerous supporting research programs dealing with various aspects of PSA. 39 refs 39 refs

  16. Status and use of PSA in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Knochenhauer, M

    1996-05-01

    The performance and use of PSA:s in Sweden goes back about two decades. During all of this time, the field of PSA has been developing intensively, both internationally and within Sweden. The latest years have been characterised by an increased use of PSA models and results, and by major extensions of existing PSA models. The aim of this document is to describe PSA in Sweden with respect to development, scope and maturity, as well as to the contents of the analyses and the use of results. PSA activities will be described from the point of view of both the authorities and the utilities. The report gives an overview of the development within the area of PSA in Sweden both its history and current trends. The aim has been to include a reasonable amount of detail, both on the methods and results in PSA:s performed and on the numerous supporting research programs dealing with various aspects of PSA. 39 refs 39 refs.

  17. Early detection of prostate cancer in Syria using T.PSA and F.PSA

    International Nuclear Information System (INIS)

    Adel, M.; Abu Daher, D.

    2009-12-01

    The aim of the current study is performing an initial prostate cancer screening test using PSA and F PSA tumour markers. A total of 3000 men in 40-75 years of age were participated in this study. Demographic and clinical data for subjects were collected by the programme staff. Total PSA and free PSA assays were determined using the ImunoTech total and free PSA assay kits, based on IRMA technique (kindly provided by the International Atomic Energy Agency). Criteria for participating in this study included : 1) men of age 50-75 (men of age as low as 40 were included in case of positive family history). 2) No previous history of prostate cancer. The following parameters were followed to refer the suspicious cases to a specialized hospital specific tests: 1)PSA>3 ng/ml . 2)High PSA value according to the participant age group. 3) Low F/TPSA ratio. In the hospital the following tests were performed:1) Complete clinical exam including DRE.2)TRUS in some cases.3) Biopsy for highly suspicious cases. 4)The low suspicious cases were retested in six months. Out of 338 cases referred to a specialized hospital, 264 cases were shown prostatic benign prostatic hyperplasia (BPH),while 36 cases proved to be prostatic cancer. However, the contact was lost in 36 cases because of changing the phone number or travelling outside the country . The detection rate of prostate cancer among all participating cases in this study was 1.2%, while this ratio was 10.7% among the referred cases. F/TPSA ratio has shown a good ability to discriminate between prostate cancer and benign prostatic hyperplasia. (author)

  18. MELCOR computer code manuals

    Energy Technology Data Exchange (ETDEWEB)

    Summers, R.M.; Cole, R.K. Jr.; Smith, R.C.; Stuart, D.S.; Thompson, S.L. [Sandia National Labs., Albuquerque, NM (United States); Hodge, S.A.; Hyman, C.R.; Sanders, R.L. [Oak Ridge National Lab., TN (United States)

    1995-03-01

    MELCOR is a fully integrated, engineering-level computer code that models the progression of severe accidents in light water reactor nuclear power plants. MELCOR is being developed at Sandia National Laboratories for the U.S. Nuclear Regulatory Commission as a second-generation plant risk assessment tool and the successor to the Source Term Code Package. A broad spectrum of severe accident phenomena in both boiling and pressurized water reactors is treated in MELCOR in a unified framework. These include: thermal-hydraulic response in the reactor coolant system, reactor cavity, containment, and confinement buildings; core heatup, degradation, and relocation; core-concrete attack; hydrogen production, transport, and combustion; fission product release and transport; and the impact of engineered safety features on thermal-hydraulic and radionuclide behavior. Current uses of MELCOR include estimation of severe accident source terms and their sensitivities and uncertainties in a variety of applications. This publication of the MELCOR computer code manuals corresponds to MELCOR 1.8.3, released to users in August, 1994. Volume 1 contains a primer that describes MELCOR`s phenomenological scope, organization (by package), and documentation. The remainder of Volume 1 contains the MELCOR Users Guides, which provide the input instructions and guidelines for each package. Volume 2 contains the MELCOR Reference Manuals, which describe the phenomenological models that have been implemented in each package.

  19. MELCOR computer code manuals

    International Nuclear Information System (INIS)

    Summers, R.M.; Cole, R.K. Jr.; Smith, R.C.; Stuart, D.S.; Thompson, S.L.; Hodge, S.A.; Hyman, C.R.; Sanders, R.L.

    1995-03-01

    MELCOR is a fully integrated, engineering-level computer code that models the progression of severe accidents in light water reactor nuclear power plants. MELCOR is being developed at Sandia National Laboratories for the U.S. Nuclear Regulatory Commission as a second-generation plant risk assessment tool and the successor to the Source Term Code Package. A broad spectrum of severe accident phenomena in both boiling and pressurized water reactors is treated in MELCOR in a unified framework. These include: thermal-hydraulic response in the reactor coolant system, reactor cavity, containment, and confinement buildings; core heatup, degradation, and relocation; core-concrete attack; hydrogen production, transport, and combustion; fission product release and transport; and the impact of engineered safety features on thermal-hydraulic and radionuclide behavior. Current uses of MELCOR include estimation of severe accident source terms and their sensitivities and uncertainties in a variety of applications. This publication of the MELCOR computer code manuals corresponds to MELCOR 1.8.3, released to users in August, 1994. Volume 1 contains a primer that describes MELCOR's phenomenological scope, organization (by package), and documentation. The remainder of Volume 1 contains the MELCOR Users Guides, which provide the input instructions and guidelines for each package. Volume 2 contains the MELCOR Reference Manuals, which describe the phenomenological models that have been implemented in each package

  20. PSA results and trends for Spain's NPPs

    International Nuclear Information System (INIS)

    Carretero, J.A.

    1993-01-01

    The Spain regulatory authority CSN demanded performance of PSA for all Spain nuclear power plants. The specific data analysis carried out as a part of the PSA has contributed to the realistic view on the results which could be achieved by the PSA. The main characteristics of the PSA in Spain and PSA trends in the development are presented in the paper

  1. The archaeology of computer codes - illustrated on the basis of the code SABINE

    International Nuclear Information System (INIS)

    Sdouz, G.

    1987-02-01

    Computer codes used by the physics group of the Institute for Reactor Safety are stored on back-up-tapes. However during the last years both the computer and the system have been changed. For new tasks these programmes have to be available. A new procedure is necessary to find and to activate a stored programme. This procedure is illustrated on the basis of the code SABINE. (Author)

  2. Implementation guidelines for seismic PSA

    International Nuclear Information System (INIS)

    Coman, Ovidiu; Samaddar, Sujit; Hibino, Kenta; )

    2014-01-01

    The presentation was devoted to development of guidelines for implementation of a seismic PSA. If successful, these guidelines can close an important gap. ASME/ANS PRA standards and the related IAEA Safety Guide (IAEA NS-G-2.13) describe capability requirements for seismic PSA in order to support risk-informed applications. However, practical guidance on how to meet these requirements is limited. Such guidelines could significantly contribute to improving risk-informed safety demonstration, safety management and decision making. Extensions of this effort to further PSA areas, particularly to PSA for other external hazards, can enhance risk-informed applications

  3. Clinical performance of serum [-2]proPSA derivatives, %p2PSA and PHI, in the detection and management of prostate cancer

    OpenAIRE

    Huang, Ya-Qiang; Sun, Tong; Zhong, Wei-De; Wu, Chin-Lee

    2014-01-01

    Prostate-specific antigen (PSA) has been widely used as a serum marker for prostate cancer (PCa) screening or progression monitoring, which dramatically increased rate of early detection while significantly reduced PCa-specific mortality. However, a number of limitations of PSA have been noticed. Low specificity of PSA may lead to overtreatment in men who presenting with a total PSA (tPSA) level of < 10 ng/mL. As a type of free PSA (fPSA), [-2]proPSA is differentially expressed in peripheral ...

  4. UV/EB curable psa's

    International Nuclear Information System (INIS)

    Glotfelter, C.A.

    1995-01-01

    The author describe both water-based and 100% solids UV/EB curable PSA's (Pressure Sensitive Adhesives) and their properties. A new acrylate monomer, ethoxylated nonyl phenol acrylate, has great utility in the formulation of water-based PSA's

  5. Reactor safety computer code development at INEL

    International Nuclear Information System (INIS)

    Johnsen, G.W.

    1985-01-01

    This report provides a brief overview of the computer code development programs being conducted at EG and G Idaho, Inc. on behalf of US Nuclear Regulatory Commission and the Department of Energy, Idaho Operations Office. Included are descriptions of the codes being developed, their development status as of the date of this report, and resident code development expertise

  6. Introduction and preparation of the nuclear fuel cycle facility risk analysis code: STAR

    International Nuclear Information System (INIS)

    Nomura, Yasushi

    1990-09-01

    STAR code is a computer program, by which one can perform the probabilistic safety assessment (PSA) for the nuclear fuel cycle facility in both the normal and the accidental event of environmental radioactive material release. This code was originally developed by NUKEM GmbH in West Germany as a fruit of the PSE (Projekt Sicherheitsstudien Entsorgung) aiming at R and D of safety analysis methods for use in nuclear fuel cycle facilities such as reprocessing plants. In JAERI, efforts have been made to research and develop safety assessment methods applicable to the accidental situations assumed to happen in the reprocessing plants. In this line of objectives, the STAR code was introduced from NUKEM GmbH in 1986 and, since then, has been improved and prepared to add an ability to analyze public radiation exposure by released activities from the plants. At the first stage of this code preparation, the program conversion was made to adapt the STAR code, originally operative on IBM-compatible PC's and Hewlett Packard 7550A plotters, to NEC PC 9801RX and NEC PR 602R page printers installed in the Fuel Cycle Safety Assessment Laboratory of JAERI. This report describes calculational performances of the STAR code, results of the improvement and preparation works together with input/output data format in illustration of a sample HALW (High Activity Liquid Waste) tank PSA problem, thus making a users' manual for the STAR code. (author)

  7. SKEMA - A computer code to estimate atmospheric dispersion

    International Nuclear Information System (INIS)

    Sacramento, A.M. do.

    1985-01-01

    This computer code is a modified version of DWNWND code, developed in Oak Ridge National Laboratory. The Skema code makes an estimative of concentration in air of a material released in atmosphery, by ponctual source. (C.M.) [pt

  8. State of living PSA and further development

    International Nuclear Information System (INIS)

    1999-01-01

    In October 1985 OECD-Principal Working Group (PWG 5) - Risk Assessment has initiated the Task Force 7 'Use of PSA in Nuclear Power Plant Management' to explore and report on the principles, characteristics, requirements and status of PSA oriented safety management. During this study, it became apparent that the utilisation of PSA techniques in nuclear plant safety management requires the development of supporting programmes to ensure that PSA models are being updated to reflect plant changes, and to direct their use towards the evaluation and determination of plant changes. These requirements also influence the software and hardware characteristics necessary to support the programme. This overall process is known as Living PSA. In this context OECD-PWG 5 has arranged international workshops on Living PSA application to support this development, to facilitate exchange of international experience and to summarise the state-of-the-art of L-PSA methodology. These activities were accompanied by following Task Groups of OECD-PWG 5 and the work results were published in state-of-the-art reports. According to the increasing development of Living PSA in the international field and its capacity to support plant safety management in a broad sense, OECD PWG 5 continues its work in setting up the Task Group 96-1 'State of Living PSA and Further Development' to clarify specific aspects of Living PSA. This report summarises the state of Living PSA in the international field based on the four Living PSA Workshops from 1988 to 1994 (Chapter 2) and the state of Reliability Data Collection based on the results of Task Group 12 'Reliability Data Collection and Analysis to Support PSA' and the two Data-Workshops from 1995 and 1998 (Chapter 3). The specific items of further development of Living PSA application as mentioned above are treated in Chapter 4. Chapter 5 gives a summary of the current state of Living PSA as well as outlook and recommendations of further development

  9. THE DISCRIMINATIVE ABILITY OF PERCENT FREE PSA IN ...

    African Journals Online (AJOL)

    Blood samples were collected from all patients, and total PSA, free PSA and % free PSA were calculated in all specimens. Total PSA was measured using the Imx ... Un prélèvement de sang a été réalisé chez tous les patients avec un dosage du PSA total et de la fraction libre de PSA. Le PSA total a été mesuré par un kit ...

  10. Insulin promotes cell migration by regulating PSA-NCAM

    Energy Technology Data Exchange (ETDEWEB)

    Monzo, Hector J.; Coppieters, Natacha [Centre for Brain Research, Faculty of Medical and Health Sciences, The University of Auckland, Private Bag, 92019, Auckland (New Zealand); Department of Anatomy and Medical Imaging, Faculty of Medical and Health Sciences, The University of Auckland, Private Bag, 92019, Auckland (New Zealand); Park, Thomas I.H. [Centre for Brain Research, Faculty of Medical and Health Sciences, The University of Auckland, Private Bag, 92019, Auckland (New Zealand); Department of Pharmacology, Faculty of Medical and Health Sciences, The University of Auckland, Private Bag, 92019, Auckland (New Zealand); Dieriks, Birger V.; Faull, Richard L.M. [Centre for Brain Research, Faculty of Medical and Health Sciences, The University of Auckland, Private Bag, 92019, Auckland (New Zealand); Department of Anatomy and Medical Imaging, Faculty of Medical and Health Sciences, The University of Auckland, Private Bag, 92019, Auckland (New Zealand); Dragunow, Mike [Centre for Brain Research, Faculty of Medical and Health Sciences, The University of Auckland, Private Bag, 92019, Auckland (New Zealand); Department of Pharmacology, Faculty of Medical and Health Sciences, The University of Auckland, Private Bag, 92019, Auckland (New Zealand); Curtis, Maurice A., E-mail: m.curtis@auckland.ac.nz [Centre for Brain Research, Faculty of Medical and Health Sciences, The University of Auckland, Private Bag, 92019, Auckland (New Zealand); Department of Anatomy and Medical Imaging, Faculty of Medical and Health Sciences, The University of Auckland, Private Bag, 92019, Auckland (New Zealand)

    2017-06-01

    Cellular interactions with the extracellular environment are modulated by cell surface polysialic acid (PSA) carried by the neural cell adhesion molecule (NCAM). PSA-NCAM is involved in cellular processes such as differentiation, plasticity, and migration, and is elevated in Alzheimer's disease as well as in metastatic tumour cells. Our previous work demonstrated that insulin enhances the abundance of cell surface PSA by inhibiting PSA-NCAM endocytosis. In the present study we have identified a mechanism for insulin-dependent inhibition of PSA-NCAM turnover affecting cell migration. Insulin enhanced the phosphorylation of the focal adhesion kinase leading to dissociation of αv-integrin/PSA-NCAM clusters, and promoted cell migration. Our results show that αv-integrin plays a key role in the PSA-NCAM turnover process. αv-integrin knockdown stopped PSA-NCAM from being endocytosed, and αv-integrin/PSA-NCAM clusters co-labelled intracellularly with Rab5, altogether indicating a role for αv-integrin as a carrier for PSA-NCAM during internalisation. Furthermore, inhibition of p-FAK caused dissociation of αv-integrin/PSA-NCAM clusters and counteracted the insulin-induced accumulation of PSA at the cell surface and cell migration was impaired. Our data reveal a functional association between the insulin/p-FAK-dependent regulation of PSA-NCAM turnover and cell migration through the extracellular matrix. Most importantly, they identify a novel mechanism for insulin-stimulated cell migration. - Highlights: • Insulin modulates PSA-NCAM turnover through upregulation of p-FAK. • P-FAK modulates αv-integrin/PSA-NCAM clustering. • αv-integrin acts as a carrier for PSA-NCAM endocytosis. • Cell migration is promoted by cell surface PSA. • Insulin promotes PSA-dependent migration in vitro.

  11. Insulin promotes cell migration by regulating PSA-NCAM

    International Nuclear Information System (INIS)

    Monzo, Hector J.; Coppieters, Natacha; Park, Thomas I.H.; Dieriks, Birger V.; Faull, Richard L.M.; Dragunow, Mike; Curtis, Maurice A.

    2017-01-01

    Cellular interactions with the extracellular environment are modulated by cell surface polysialic acid (PSA) carried by the neural cell adhesion molecule (NCAM). PSA-NCAM is involved in cellular processes such as differentiation, plasticity, and migration, and is elevated in Alzheimer's disease as well as in metastatic tumour cells. Our previous work demonstrated that insulin enhances the abundance of cell surface PSA by inhibiting PSA-NCAM endocytosis. In the present study we have identified a mechanism for insulin-dependent inhibition of PSA-NCAM turnover affecting cell migration. Insulin enhanced the phosphorylation of the focal adhesion kinase leading to dissociation of αv-integrin/PSA-NCAM clusters, and promoted cell migration. Our results show that αv-integrin plays a key role in the PSA-NCAM turnover process. αv-integrin knockdown stopped PSA-NCAM from being endocytosed, and αv-integrin/PSA-NCAM clusters co-labelled intracellularly with Rab5, altogether indicating a role for αv-integrin as a carrier for PSA-NCAM during internalisation. Furthermore, inhibition of p-FAK caused dissociation of αv-integrin/PSA-NCAM clusters and counteracted the insulin-induced accumulation of PSA at the cell surface and cell migration was impaired. Our data reveal a functional association between the insulin/p-FAK-dependent regulation of PSA-NCAM turnover and cell migration through the extracellular matrix. Most importantly, they identify a novel mechanism for insulin-stimulated cell migration. - Highlights: • Insulin modulates PSA-NCAM turnover through upregulation of p-FAK. • P-FAK modulates αv-integrin/PSA-NCAM clustering. • αv-integrin acts as a carrier for PSA-NCAM endocytosis. • Cell migration is promoted by cell surface PSA. • Insulin promotes PSA-dependent migration in vitro.

  12. Prevalence and causes of abnormal PSA recovery.

    Science.gov (United States)

    Lautenbach, Noémie; Müntener, Michael; Zanoni, Paolo; Saleh, Lanja; Saba, Karim; Umbehr, Martin; Velagapudi, Srividya; Hof, Danielle; Sulser, Tullio; Wild, Peter J; von Eckardstein, Arnold; Poyet, Cédric

    2018-01-26

    Prostate-specific antigen (PSA) test is of paramount importance as a diagnostic tool for the detection and monitoring of patients with prostate cancer. In the presence of interfering factors such as heterophilic antibodies or anti-PSA antibodies the PSA test can yield significantly falsified results. The prevalence of these factors is unknown. We determined the recovery of PSA concentrations diluting patient samples with a standard serum of known PSA concentration. Based on the frequency distribution of recoveries in a pre-study on 268 samples, samples with recoveries 120% were defined as suspect, re-tested and further characterized to identify the cause of interference. A total of 1158 consecutive serum samples were analyzed. Four samples (0.3%) showed reproducibly disturbed recoveries of 10%, 68%, 166% and 4441%. In three samples heterophilic antibodies were identified as the probable cause, in the fourth anti-PSA-autoantibodies. The very low recovery caused by the latter interference was confirmed in serum, as well as heparin- and EDTA plasma of blood samples obtained 6 months later. Analysis by eight different immunoassays showed recoveries ranging between PSA which however did not show any disturbed PSA recovery. About 0.3% of PSA determinations by the electrochemiluminescence assay (ECLIA) of Roche diagnostics are disturbed by heterophilic or anti-PSA autoantibodies. Although they are rare, these interferences can cause relevant misinterpretations of a PSA test result.

  13. PSA levels as a predictor of 68Ga PSMA PET/CT positivity in patients with prostate cancer?

    Science.gov (United States)

    Soydal, Cigdem; Urun, Yuksel; Suer, Evren; Nak, Demet; Ozkan, Elgin; Kucuk, Ozlem N

    2018-05-10

    The aim of this study is to evaluate predictive factors of 68Gallium (68Ga) Prostate-Specific Membrane Antigen (PSMA) Positron Emission Tomography (PET)/Computed Tomography (CT) positivity. Relationships between serum Prostate Specific Antigen (PSA), Lactate dehydrogenase (LDH) and alkaline phosphatase (ALP) levels, Gleason Score (GS) and positivity of 68Ga PSMA PET in patients who underwent 68Ga PSMA PET/CT for restaging for PCa were evaluated retrospectively. One hundred and four (median age: 67; range: 51-88) patients were included in this study. Of these patients, PSMA PET was positive in 75 (72%) patients. Mean serum PSA levels for PET negative and positive groups were 0.76±1.00 and 180.85±324.93 ng/ml (pPSA cut-off and 92% and 90%, respectively, for the 2 ng/ml PSA cut-off values. The positivity rates for patients with PSA levels PSA recurrence. Patients with higher GS and early PSA recurrence could benefit from 68Ga PSMA PET/CT.

  14. Computer code qualification program for the Advanced CANDU Reactor

    International Nuclear Information System (INIS)

    Popov, N.K.; Wren, D.J.; Snell, V.G.; White, A.J.; Boczar, P.G.

    2003-01-01

    Atomic Energy of Canada Ltd (AECL) has developed and implemented a Software Quality Assurance program (SQA) to ensure that its analytical, scientific and design computer codes meet the required standards for software used in safety analyses. This paper provides an overview of the computer programs used in Advanced CANDU Reactor (ACR) safety analysis, and assessment of their applicability in the safety analyses of the ACR design. An outline of the incremental validation program, and an overview of the experimental program in support of the code validation are also presented. An outline of the SQA program used to qualify these computer codes is also briefly presented. To provide context to the differences in the SQA with respect to current CANDUs, the paper also provides an overview of the ACR design features that have an impact on the computer code qualification. (author)

  15. Management and organisational factors in PSA; Organisations- und Management-Faktoren in der PSA

    Energy Technology Data Exchange (ETDEWEB)

    Balfanz, H.P. [TUEV Nord e.V., Hamburg (Germany)

    1999-04-01

    The constraints of PSA are increasingly considered with increasing application of PSA for the safety management of nuclear power plants (see US-NRC, 'Risk Informed Regulation', NRC-1). There is a vivid international discourse about the applicability of the variables of plant management and organisation in PSAs, which has lead to a great variety of research activities into this matter (see PSAM 4). This paper here summarizes the current state of progress of research work and discusses the applicability of results. The studies for comparative assessment of methodology and results were performed by the TUeV Nord under the roof of the BMU/BfS-sponsored project SR 2260, ''Further development of probabilistic methods for nuclear power plant safety assessment. (orig./CB) [German] Mit zunehmender Anwendung der PSA (Probabilistische Sicherheitsanalyse) im Sicherheitsmanagement von KKW (vergl. US-NRC, Einfuehrung des Konzepts 'Risk Informed Regulation' NRC-1) gewinnt die Beachtung der Grenzen der PSA zusaetzliche Bedeutung. International ist eine intensive Diskussion ueber die Moeglichkeiten einer Einbindung der Einflussgroesse von Organisation und Management in der PSA zu verzeichnen und wird belegt durch vielfaeltige Forschungs- und Entwicklungsarbeiten (vergl. PSAM 4). Dieser Beitrag setzt sich in erster Linie mit diesem Entwicklungsstand auseinander und diskutiert seinen Anwendungsstand fuer die PSA. Die hierzu vom TUeV Nord durchgefuehrten Arbeiten basieren auf dem BMU/BfS-Vorhaben SR 2260, 'Weiterentwicklung probabilistischer Methoden zur Sicherheitsbeurteilung von KKW'. (orig.)

  16. Low Computational Complexity Network Coding For Mobile Networks

    DEFF Research Database (Denmark)

    Heide, Janus

    2012-01-01

    Network Coding (NC) is a technique that can provide benefits in many types of networks, some examples from wireless networks are: In relay networks, either the physical or the data link layer, to reduce the number of transmissions. In reliable multicast, to reduce the amount of signaling and enable......-flow coding technique. One of the key challenges of this technique is its inherent computational complexity which can lead to high computational load and energy consumption in particular on the mobile platforms that are the target platform in this work. To increase the coding throughput several...

  17. Computer code conversion using HISTORIAN

    International Nuclear Information System (INIS)

    Matsumoto, Kiyoshi; Kumakura, Toshimasa.

    1990-09-01

    When a computer program written for a computer A is converted for a computer B, in general, the A version source program is rewritten for B version. However, in this way of program conversion, the following inconvenient problems arise. 1) The original statements to be rewritten for B version are lost. 2) If the original statements of the A version rewritten for B version would remain as comment lines, the B version source program becomes quite large. 3) When update directives of the program are mailed from the organization which developed the program or when some modifications are needed for the program, it is difficult to point out the part to be updated or modified in the B version source program. To solve these problems, the conversion method using the general-purpose software management aid system, HISTORIAN, has been introduced. This conversion method makes a large computer code a easy-to-use program for use to update, modify or improve after the conversion. This report describes the planning and procedures of the conversion method and the MELPROG-PWR/MOD1 code conversion from the CRAY version to the JAERI FACOM version as an example. This report would provide useful information for those who develop or introduce large programs. (author)

  18. Continuous Materiality: Through a Hierarchy of Computational Codes

    Directory of Open Access Journals (Sweden)

    Jichen Zhu

    2008-01-01

    Full Text Available The legacy of Cartesian dualism inherent in linguistic theory deeply influences current views on the relation between natural language, computer code, and the physical world. However, the oversimplified distinction between mind and body falls short of capturing the complex interaction between the material and the immaterial. In this paper, we posit a hierarchy of codes to delineate a wide spectrum of continuous materiality. Our research suggests that diagrams in architecture provide a valuable analog for approaching computer code in emergent digital systems. After commenting on ways that Cartesian dualism continues to haunt discussions of code, we turn our attention to diagrams and design morphology. Finally we notice the implications a material understanding of code bears for further research on the relation between human cognition and digital code. Our discussion concludes by noticing several areas that we have projected for ongoing research.

  19. Time to PSA rise differentiates the PSA bounce after HDR and LDR brachytherapy of prostate cancer.

    Science.gov (United States)

    Burchardt, Wojciech; Skowronek, Janusz

    2018-02-01

    To investigate the differences in prostate-specific antigen (PSA) bounce (PB) after high-dose-rate (HDR-BT) or low-dose-rate (LDR-BT) brachytherapy alone in prostate cancer patients. Ninety-four patients with localized prostate cancer (T1-T2cN0), age ranged 50-81 years, were treated with brachytherapy alone between 2008 and 2010. Patients were diagnosed with adenocarcinoma, Gleason score ≤ 7. The LDR-BT total dose was 144-145 Gy, in HDR-BT - 3 fractions of 10.5 or 15 Gy. The initial PSA level (iPSA) was assessed before treatment, then PSA was rated every 3 months over the first 2 years, and every 6 months during the next 3 years. Median follow-up was 3.0 years. Mean iPSA was 7.8 ng/ml. In 58 cases, PSA decreased gradually without PB or biochemical failure (BF). In 24% of patients, PB was observed. In 23 cases (24%), PB was observed using 0.2 ng/ml definition; in 10 cases (11%), BF was diagnosed using nadir + 2 ng/ml definition. The HDR-BT and LDR-BT techniques were not associated with higher level of PB (26 vs. 22%, p = 0.497). Time to the first PSA rise finished with PB was significantly shorter after HDR-BT then after LDR-BT (median, 10.5 vs. 18.0 months) during follow-up. Predictors for PB were observed only after HDR-BT. Androgen deprivation therapy (ADT) and higher Gleason score decreased the risk of PB (HR = 0.11, p = 0.03; HR = 0.51, p = 0.01). The higher PSA nadir and longer time to PSA nadir increased the risk of PB (HR 3.46, p = 0.02; HR 1.04, p = 0.04). There was no predictors for PB after LDR-BT. HDR-BT and LDR-BT for low and intermediate risk prostate cancer had similar PB rate. The PB occurred earlier after HDR-BT than after LDR-BT. ADT and higher Gleason score decreased, and higher PSA nadir and longer time to PSA nadir increased the risk of PB after HDR-BT.

  20. Holonomic surface codes for fault-tolerant quantum computation

    Science.gov (United States)

    Zhang, Jiang; Devitt, Simon J.; You, J. Q.; Nori, Franco

    2018-02-01

    Surface codes can protect quantum information stored in qubits from local errors as long as the per-operation error rate is below a certain threshold. Here we propose holonomic surface codes by harnessing the quantum holonomy of the system. In our scheme, the holonomic gates are built via auxiliary qubits rather than the auxiliary levels in multilevel systems used in conventional holonomic quantum computation. The key advantage of our approach is that the auxiliary qubits are in their ground state before and after each gate operation, so they are not involved in the operation cycles of surface codes. This provides an advantageous way to implement surface codes for fault-tolerant quantum computation.

  1. State of the art of probabilistic safety analysis (PSA) in the FRG, and principles of a PSA-guideline

    International Nuclear Information System (INIS)

    Balfanz, H.P.

    1987-01-01

    Contents of the articles: Survey of PSA performed during licensing procedures of an NPP; German Nuclear Standards' requirements on the reliability of safety systems; PSA-guideline for NPP: Principles and suggestions; Motivation and tasks of PSA; Aspects of the methodology of safety analyses; Structure of event tree and fault tree analyses; Extent of safety analyses; Performance and limits of PSA. (orig./HSCH)

  2. The FOCON96 1.0 computer code

    International Nuclear Information System (INIS)

    Merle-Szeremeta, A.; Thomassin, A.

    1999-01-01

    The Institute of Protection and Nuclear Safety (I.P.S.N.) has developed a computer code, FOCON96 1.0 to calculate the dosimetric consequences of atmospheric radioactive releases from nuclear installations after several years of usual operation. This communication describes the principal characteristics of FOCON96 1.0 and its functionalities. The principal elements of a comparison between FOCON96 1.0 and PC-CREAM ( European computer code developed by the N.R.P.B. and answering the same criteria) are given here. (N.C.)

  3. Blackpool: More evidence on PSA

    International Nuclear Information System (INIS)

    Cullingford, M.

    1985-01-01

    PSA is spreading widely throughout the world, with 30 IAEA Member States having active programmes in this area. The main reason for its popularity is that it offers insights critical in the safety decision-making process available from no other method. It allows power plant designers, regulators, and operators to discriminate between issues important to safety and those which are trivial. Although it is beneficial to perform a PSA to utilize the potential products available from such a study, it is especially important to realize that the PSA process itself is a valuable experience. The main points such as potential users of PSA, safety evaluations, treatment of uncertainties as well as future trends are briefly discussed in this paper

  4. Development of PSA audit guideline and regulatory PSA model for SMART

    International Nuclear Information System (INIS)

    Cho, Namchul; Lee, Chang-Ju; Kim, I.S.

    2012-01-01

    SMART is under development for dual purposes of power generation and seawater desalination in Korea. It is an integral reactor type with a thermal power output of 330 MW and employs advanced design features such as a passive system for the removal of residual heat and also the setting of all the components of the primary system inside the reactor pressure vessel. It is essential to develop new probabilistic safety assessment (PSA) validation guidance for SMART. For the purpose of regulatory verification to the risk level of SMART, the insights and key issues on the PSA are identified with referring some worldwide safety guides as well as its design characteristics. Regulatory PSA model under the development for the design confirmation and its preliminary result are also described. (authors)

  5. Computer Security: is your code sane?

    CERN Multimedia

    Stefan Lueders, Computer Security Team

    2015-01-01

    How many of us write code? Software? Programs? Scripts? How many of us are properly trained in this and how well do we do it? Do we write functional, clean and correct code, without flaws, bugs and vulnerabilities*? In other words: are our codes sane?   Figuring out weaknesses is not that easy (see our quiz in an earlier Bulletin article). Therefore, in order to improve the sanity of your code, prevent common pit-falls, and avoid the bugs and vulnerabilities that can crash your code, or – worse – that can be misused and exploited by attackers, the CERN Computer Security team has reviewed its recommendations for checking the security compliance of your code. “Static Code Analysers” are stand-alone programs that can be run on top of your software stack, regardless of whether it uses Java, C/C++, Perl, PHP, Python, etc. These analysers identify weaknesses and inconsistencies including: employing undeclared variables; expressions resu...

  6. High performance computer code for molecular dynamics simulations

    International Nuclear Information System (INIS)

    Levay, I.; Toekesi, K.

    2007-01-01

    Complete text of publication follows. Molecular Dynamics (MD) simulation is a widely used technique for modeling complicated physical phenomena. Since 2005 we are developing a MD simulations code for PC computers. The computer code is written in C++ object oriented programming language. The aim of our work is twofold: a) to develop a fast computer code for the study of random walk of guest atoms in Be crystal, b) 3 dimensional (3D) visualization of the particles motion. In this case we mimic the motion of the guest atoms in the crystal (diffusion-type motion), and the motion of atoms in the crystallattice (crystal deformation). Nowadays, it is common to use Graphics Devices in intensive computational problems. There are several ways to use this extreme processing performance, but never before was so easy to programming these devices as now. The CUDA (Compute Unified Device) Architecture introduced by nVidia Corporation in 2007 is a very useful for every processor hungry application. A Unified-architecture GPU include 96-128, or more stream processors, so the raw calculation performance is 576(!) GFLOPS. It is ten times faster, than the fastest dual Core CPU [Fig.1]. Our improved MD simulation software uses this new technology, which speed up our software and the code run 10 times faster in the critical calculation code segment. Although the GPU is a very powerful tool, it has a strongly paralleled structure. It means, that we have to create an algorithm, which works on several processors without deadlock. Our code currently uses 256 threads, shared and constant on-chip memory, instead of global memory, which is 100 times slower than others. It is possible to implement the total algorithm on GPU, therefore we do not need to download and upload the data in every iteration. On behalf of maximal throughput, every thread run with the same instructions

  7. Computer codes for shaping the magnetic field of the JINR phasotron

    International Nuclear Information System (INIS)

    Zaplatin, N.L.; Morozov, N.A.

    1983-01-01

    The computer codes providing for the shaping the magnetic field of the JINR high current phasotron are presented. Using these codes the control for the magnetic field mapping was realized in on- or off-line regimes. Then these field parameters were calculated and ferromagnetic correcting elements and trim coils setting were chosen. Some computer codes were realised for the magnetic field horizontal component measurements. The data are presented on some codes possibilities. The codes were used on the EC-1010 and the CDC-6500 computers

  8. COMPUTATION FORMAT computer codes X4TOC4 and PLOTC4. Implementing and Testing on a Personal Computer

    International Nuclear Information System (INIS)

    McLaughlin, P.K.

    1987-05-01

    This document describes the contents of the diskette containing the COMPUTATION FORMAT codes X4TOC4 and PLOTC4 by D.E. Cullen, and example data for use in implementing and testing these codes on a Personal Computer of the type IBM-PC/AT. Upon request the codes are available from the IAEA Nuclear Data Section, free of charge, on a single diskette. (author)

  9. Use of simplified PSA studies in support of the ASTRID design process

    International Nuclear Information System (INIS)

    Gauthe, P.; Curnier, F.; Bertrand, F.; Vincon, L.; Jouve, S.; Balmain, M.; Rychkov, V.; Banchieri, Y.

    2012-01-01

    In the framework of the French Act of 28 June 2006 about nuclear materials and waste management, a GEN IV and actinides incineration demonstration prototype is to be commissioned in the 2020 decade. In this objective a prototype called ASTRID (Advanced Sodium Technological Reactor for Industrial Demonstration) is proposed to demonstrate the progress made in SFR technology at an industrial scale by qualifying innovative options, some of which still remain open in the areas requiring improvements, especially safety and operability. More specifically, we aim for a level of safety that is at least equivalent to that of the EPR (third generation), with improvements made in SFR-specific fields. The integration of safety issues in the early phase of the design of ASTRID is necessarily expected. For this purpose, CEA and its partners AREVA and EDF have planned to perform a level-1 PSA to support and orientate the preliminary design of ASTRID reactor. This paper presents the PSA approach and current studies for the assessment of safety systems and the future work to be done for the 2012-2014 period. The preliminary preparation of PSA studies is presented: objectives and scope of the early design phase PSA, definition of core damage states, selection and grouping of initiating events, assessment of safety functions and related systems. Work under progress is also presented: modelling of event trees, construction of fault trees of safety systems, transient calculations of accident sequences with the CATHARE2 code and reliability data assessment. Main objectives of a level-1 PSA performed at conceptual design stage are an early assessment of the safety architecture of the reactor and findings about the most effective areas for improvement, but also the identification of dominant accident sequences and comparison with alternative designs. After the elaboration of a simplified level-1 PSA model for nominal state and main internal initiators, various design alternatives will be

  10. ASAMPSA-E guidance for level 2 PSA Volume 2. Implementing external Events modelling in Level 2 PSA

    International Nuclear Information System (INIS)

    Cazzoli, E.; Vitazkova, J.; Loeffler, H.; Burgazzi, L.

    2016-01-01

    The objective of the present document is to provide guidance on the implementation of external events into an 'extended' L2 PSA. It has to be noted that L2 PSA addresses issues beginning with fuel degradation and ending with the release of radionuclides into the environment. Therefore, the present document may touch upon, but does not evaluate explicitly issues that involve events or phenomena which occur before the fuel begins to degrade. Following the accident at Fukushima Dai-ichi, the nuclear safety community has realized that much attention should be given to the areas of operator interventions and accidents that may develop at the same time in more than one unit if they are initiated by one or more common external events. For this reason and to fulfill the PSA end-users' wish list (as reflected by an ASAMPSA-E survey), the attention is mostly focused on interface between L1 and L2 PSA, fragility analysis, human response analysis and some consideration is given to L2 PSA modeling of severe accidents for multiple unit sites, even though it is premature to provide extensive guidance in this area. The following recommendations, mentioned in various sections within this document, are summarized here: 1. Vulnerability/fragility analyses should be performed with respect to all external hazards and all structures, systems and components potentially affected that could be relevant to L2 PSA, 2. Importance should be given to the assessment of human performance following extreme external events; for extreme circumstances with high stress level, low confidence is justified for SAM human interventions and for such conditions, human interventions could be analyzed as sensitivity cases only in L2 PSA, 3. Results presentation should include assessment of total risk measures compared with risk targets able to assess all contributions to the risk and to judge properly the safety, 4. Total risk measures shall be associated to appropriate information on all

  11. Murine polyomavirus virus-like particles carrying full-length human PSA protect BALB/c mice from outgrowth of a PSA expressing tumor.

    Directory of Open Access Journals (Sweden)

    Mathilda Eriksson

    Full Text Available Virus-like particles (VLPs consist of capsid proteins from viruses and have been shown to be usable as carriers of protein and peptide antigens for immune therapy. In this study, we have produced and assayed murine polyomavirus (MPyV VLPs carrying the entire human Prostate Specific Antigen (PSA (PSA-MPyVLPs for their potential use for immune therapy in a mouse model system. BALB/c mice immunized with PSA-MPyVLPs were only marginally protected against outgrowth of a PSA-expressing tumor. To improve protection, PSA-MPyVLPs were co-injected with adjuvant CpG, either alone or loaded onto murine dendritic cells (DCs. Immunization with PSA-MPyVLPs loaded onto DCs in the presence of CpG was shown to efficiently protect mice from tumor outgrowth. In addition, cellular and humoral immune responses after immunization were examined. PSA-specific CD4(+ and CD8(+ cells were demonstrated, but no PSA-specific IgG antibodies. Vaccination with DCs loaded with PSA-MPyVLPs induced an eight-fold lower titre of anti-VLP antibodies than vaccination with PSA-MPyVLPs alone. In conclusion, immunization of BALB/c mice with PSA-MPyVLPs, loaded onto DCs and co-injected with CpG, induces an efficient PSA-specific tumor protective immune response, including both CD4(+ and CD8(+ cells with a low induction of anti-VLP antibodies.

  12. Murine Polyomavirus Virus-Like Particles Carrying Full-Length Human PSA Protect BALB/c Mice from Outgrowth of a PSA Expressing Tumor

    Science.gov (United States)

    Eriksson, Mathilda; Andreasson, Kalle; Weidmann, Joachim; Lundberg, Kajsa; Tegerstedt, Karin

    2011-01-01

    Virus-like particles (VLPs) consist of capsid proteins from viruses and have been shown to be usable as carriers of protein and peptide antigens for immune therapy. In this study, we have produced and assayed murine polyomavirus (MPyV) VLPs carrying the entire human Prostate Specific Antigen (PSA) (PSA-MPyVLPs) for their potential use for immune therapy in a mouse model system. BALB/c mice immunized with PSA-MPyVLPs were only marginally protected against outgrowth of a PSA-expressing tumor. To improve protection, PSA-MPyVLPs were co-injected with adjuvant CpG, either alone or loaded onto murine dendritic cells (DCs). Immunization with PSA-MPyVLPs loaded onto DCs in the presence of CpG was shown to efficiently protect mice from tumor outgrowth. In addition, cellular and humoral immune responses after immunization were examined. PSA-specific CD4+ and CD8+ cells were demonstrated, but no PSA-specific IgG antibodies. Vaccination with DCs loaded with PSA-MPyVLPs induced an eight-fold lower titre of anti-VLP antibodies than vaccination with PSA-MPyVLPs alone. In conclusion, immunization of BALB/c mice with PSA-MPyVLPs, loaded onto DCs and co-injected with CpG, induces an efficient PSA-specific tumor protective immune response, including both CD4+ and CD8+ cells with a low induction of anti-VLP antibodies. PMID:21858228

  13. Issues reporting PSA in prostate cancer

    International Nuclear Information System (INIS)

    Lange, Paul H.

    1996-01-01

    The National Cancer Institute Prostate; Lung; Colon; Ovarian Cancer Screening (PLCO) project is a multi-center trial developed to investigate the effectiveness of DRE and PSA testing in the early detection and outcome of patients with prostate cancer. Accordingly, the Prostate Cancer Intervention versus Observation Trial (PIVOT) has been launched and is a randomized trial comparing radical prostatectomy versus expectant management for ALCaP. PSA: Initially PSA was thought to be of little value for diagnosis because 20% of men undergoing radical prostatectomy have 'normal' PSA and patients with apparently only symptomatic BPH have 'elevated' levels as follows: 4-10 ng/ml (Tandem-R) - 20%, >10 ng/ml -3%. Yet, PSA has looked attractive as a diagnostic tool in many studies; for example, when PSA was used in a screening approach as the first test which then drove further evaluation (Catalona, Brawer). It was shown that the positive predictive value for PSA's between 4 and 10 is approximately 20% and > 10 approximately 55%. The value of serial PSA's (velocity) is unknown but is under intense study: one major issue is determination of what represents a significant rise (details to be presented). Studies have also revealed that a DRE and PSA are important for optimal results. About 18% of clinically detectable cancers are only DRE positive while about 25 - 30% are only PSA positive. When both a DRE and PSA are used together, very few clinically apparent cancers are missed (3-5%). Recent ROC curves suggest that 4 ng/ml is reasonable. Recently, PSA values for men without apparent cancer were stratified by age, and taking the 2SD, age specific reference values were generated as follows: age 40-49 (0-2.5 ng/ml), 50-59 (0-3.5), 60-69 (0-4.5), 70-70 (0-6.5). Finally, there is the issue about different PSA assays regarding the compatabilities/reliability of the upper limit of normal and serial values. Much of the confusion is because there is no international PSA standard and

  14. Results of comparative RBMK neutron computation using VNIIEF codes (cell computation, 3D statics, 3D kinetics). Final report

    Energy Technology Data Exchange (ETDEWEB)

    Grebennikov, A.N.; Zhitnik, A.K.; Zvenigorodskaya, O.A. [and others

    1995-12-31

    In conformity with the protocol of the Workshop under Contract {open_quotes}Assessment of RBMK reactor safety using modern Western Codes{close_quotes} VNIIEF performed a neutronics computation series to compare western and VNIIEF codes and assess whether VNIIEF codes are suitable for RBMK type reactor safety assessment computation. The work was carried out in close collaboration with M.I. Rozhdestvensky and L.M. Podlazov, NIKIET employees. The effort involved: (1) cell computations with the WIMS, EKRAN codes (improved modification of the LOMA code) and the S-90 code (VNIIEF Monte Carlo). Cell, polycell, burnup computation; (2) 3D computation of static states with the KORAT-3D and NEU codes and comparison with results of computation with the NESTLE code (USA). The computations were performed in the geometry and using the neutron constants presented by the American party; (3) 3D computation of neutron kinetics with the KORAT-3D and NEU codes. These computations were performed in two formulations, both being developed in collaboration with NIKIET. Formulation of the first problem maximally possibly agrees with one of NESTLE problems and imitates gas bubble travel through a core. The second problem is a model of the RBMK as a whole with imitation of control and protection system controls (CPS) movement in a core.

  15. Cutset Quantification Error Evaluation for Shin-Kori 1 and 2 PSA model

    International Nuclear Information System (INIS)

    Choi, Jong Soo

    2009-01-01

    Probabilistic safety assessments (PSA) for nuclear power plants (NPPs) are based on the minimal cut set (MCS) quantification method. In PSAs, the risk and importance measures are computed from a cutset equation mainly by using approximations. The conservatism of the approximations is also a source of quantification uncertainty. In this paper, exact MCS quantification methods which are based on the 'sum of disjoint products (SDP)' logic and Inclusion-exclusion formula are applied and the conservatism of the MCS quantification results in Shin-Kori 1 and 2 PSA is evaluated

  16. Use of PSA in a regulatory framework

    International Nuclear Information System (INIS)

    Ross, P.J.

    1994-01-01

    The paper will briefly describe the use of PSA in the licensing process for the Sizewell 'B' PWR Power Station currently under construction in the U.K. There are two distinct phases in the licensing process - (i) A PSA has been performed to support the application to construct Sizewell 'B'. At that stage the PSA was used as a design tool (along with deterministic design requirements) for Sizewell 'B' and as such lead to a number of significant design changes in the early design process. (ii) A PSA is currently being performed to support the application to operate Sizewell 'B'. The PSA is required to support the claim that the design has included all reasonably practical measures to prevent and mitigate accidents. The comprehensive PSA being produced for the second phase of the licensing process will be described. The way the regulators/designer/analysts have interacted over the years has affected the scope, complexity, detail and bias of the comprehensive PSA. The paper will discuss these issues and highlight some of the more significant ones. The benefits and drawbacks of providing a PSA in a regulatory framework will be discussed. One of the conclusions of the paper is that the use of true ''best-estimates'' in the PSA is difficult to achieve in a regulatory framework where persistent bias to the conservative side is apparent in the designers, analysts and regulators judgements. The usefulness of the PSA is therefore, potentially, compromised by giving misleading outputs or diverting resources to unnecessary areas. (author)

  17. A PSA study for the SMART basic design

    International Nuclear Information System (INIS)

    Han, Sang Hoon; Kim, H. C.; Yang, S. H.; Lee, D. J.

    2002-03-01

    SMART (System-Integrated Modular Advanced Reactor) is under development that is an advanced integral type small and medium category nuclear power reactor with the rated thermal power of 330 MW. A Probabilistic Safety Analysis (PSA) for the SMART basic design has been performed to evaluate the safety and optimize the design. Currently, the basic design is done and the detailed design is not available for the SMART, we made several assumptions about the system design before performing the PSA. The scope of the PSA was limited to the Level-1 internal full power PSA. The level-2 and 3 PSA, the external PSA, and the low power/shutdown PSA will be performed in the final design stage

  18. PSA methodology

    International Nuclear Information System (INIS)

    Magne, L.

    1996-01-01

    The purpose of this text is first to ask a certain number of questions on the methods related to PSAs. Notably we will explore the positioning of the French methodological approach - as applied in the EPS 1300 1 and EPS 900 2 PSAs - compared to other approaches (Part One). This reflection leads to more general reflection: what contents, for what PSA? This is why, in Part Two, we will try to offer a framework for definition of the criteria a PSA should satisfy to meet the clearly identified needs. Finally, Part Three will quickly summarize the questions approached in the first two parts, as an introduction to the debate. 15 refs

  19. PSA in America

    International Nuclear Information System (INIS)

    Linn, M.A.; Cunningham, M.A.; Johnson, D.H.

    1996-01-01

    Although the concept of acceptable risk has always been the foundation of the nuclear industry design, the use of formal PSA (or PRA-probabilistic risk assessment) in the U.S. nuclear power industry has followed an unusual path in arriving at its current level of notability. Prior to 1975, probabilistic evaluations were limited to a few specific applications such as the evaluation of man-made (i.e., airplane crashes) and natural (i.e., earthquakes) hazards. In 1975, the industry was introduced to comprehensive PSA by the Reactor Safety Study (WASH-1400). However, the study languished in relative obscurity until the accident at Three Mile Island 2 (TMI-2) in 1979. This event significantly altered the industry's view of severe accidents in the U.S. and worldwide. Investigative committees of TMI-2 recommended that PSA techniques be more widely used to augment the traditional deterministic methods of determining nuclear plant safety. This initiated an unprecedented effort by nuclear regulators and licensees worldwide to significantly improve the state of knowledge of severe accidents at nuclear power plants. In the U.S., use of PSA began to increase as evidenced by its application in the anticipated transient without scram and station blackout rulemakings, generic issue prioritization and resolution, risk-based inspection guidelines, backfit policy, and technical specification improvements. However, broad application of probabilistic techniques to the industry as a whole was initiated in 1986 with the publication of Safety Goals for the Operation of Nuclear Power Plant; Policy Statement. This put PSA front and center in the U.S. regulatory arena by open-quotes establish[ing] goals that broadly define an acceptable level of radiological risk that might be imposed on the public as a result of nuclear power plant operation.close quotes Both qualitative safety goals and quantitative objectives were articulated in this policy statement

  20. Seismic Level 2 PSA

    International Nuclear Information System (INIS)

    Dirksen, Gerben; Pellissetti, Manuel; Duncan-Whiteman, Paul

    2014-01-01

    For most external events, the calculation of the core damage frequency (CDF) in Level 1 PSA is sufficient to be able to show that the contribution of the event to the plant risk is negligible. However, it is not sufficient to compare the CDF due to the external event to the total plant CDF; instead the Level 1 PSA result for the event should be compared to the large early release frequency (LERF), or alternatively arguments should be given why the CDF from the external event will not contribute mostly to LERF. For seismic events in particular, it can often not be easily excluded that sequences leading to core damage would not also result in LERF. Since the confinement function is one of the most essential functions for Level 2 PSA, special care must be taken of the containment penetrations. For example systems with containment penetrations that are normally closed during operation or are designed to withstand more than the maximum containment pressure are normally screened out in the Level 2 PSA for the containment isolation function, however the possibility of LOCA in such systems due to an earthquake may nevertheless lead to containment bypass. Additionally, the functionality of passive features may be compromised in case of a beyond design earthquake. In the present paper, we present crucial ingredients of a methodology for a Level 2 seismic PSA. This methodology consists of the following steps: Extension of the seismic equipment list (SEL) to include Level 2 PSA relevant systems (e.g. containment isolation system, features for core melt stabilization, hydrogen mitigation systems), Determination of the systems within the existing SEL with increased demands in case of severe accidents, Determination of essential components for which a dedicated fragility analysis needs to be performed. (author)

  1. User manual of FRAPCON-I computer code

    International Nuclear Information System (INIS)

    Chia, C.T.

    1985-11-01

    The manual for using the FRAPCON-I code implanted by Reactor Department of Brazilian-CNEN to convert IBM FORTRAN in FORTRAN 77 of Honeywell Bull computer is presented. The FRAPCON-I code describes the behaviour of fuel rods of PWR type reactors at stationary state during long periods of burnup. (M.C.K.)

  2. Clinical diagnostic value of combined determination of serum tPSA, cPSA and IGF-I levels in patients with prostatic disorders

    International Nuclear Information System (INIS)

    Zhang Bashan; Zhang Zigang; Lai Fudi

    2008-01-01

    Objective: To investigate the diagnostic value of combined determination of serum total prostatic specific antigen (tPSA), complex prostatic specific antigen (cPSA) and IGF-I levels in patients with prostatic disorders. Methods: Serum tPSA, cPSA (with CLIA) and IGF-I (with IRMA) levels were determined in 41 patients with prostatic carcinoma, 60 patients with benign prosta- tic hypertrophy (BPH) and 55 controls. Results: The serum tPSA, cPSA and IGF-I levels in patients with prostatic cancer were significantly higher than those in patients with BPH and controls (P<0.01). Taking the cut-off values of 4ng/ml, 3.6ng/ml and 150 for tPSA, cPSA and IGF-I respectively, the combined determination of these three items would yield a sensitivity of 88.6%, specificity of 84.9%, positive predicative value of 83% and negative predicative value of 90.0% for diagnosis of prostatic cancer. Conclusion: Combined determination of tPSA, cPSA and IGF-I would yield better sensitive and accurate diagnostic rate in patients with prostatic cancer, especially in those with laboratory values within the 'grey zone'. (authors)

  3. Some neutronics and thermal-hydraulics codes for reactor analysis using personal computers

    International Nuclear Information System (INIS)

    Woodruff, W.L.

    1990-01-01

    Some neutronics and thermal-hydraulics codes formerly available only for main frame computers may now be run on personal computers. Brief descriptions of the codes are provided. Running times for some of the codes are compared for an assortment of personal and main frame computers. With some limitations in detail, personal computer versions of the codes can be used to solve many problems of interest in reactor analyses at very modest costs. 11 refs., 4 tabs

  4. Quantum computation with topological codes from qubit to topological fault-tolerance

    CERN Document Server

    Fujii, Keisuke

    2015-01-01

    This book presents a self-consistent review of quantum computation with topological quantum codes. The book covers everything required to understand topological fault-tolerant quantum computation, ranging from the definition of the surface code to topological quantum error correction and topological fault-tolerant operations. The underlying basic concepts and powerful tools, such as universal quantum computation, quantum algorithms, stabilizer formalism, and measurement-based quantum computation, are also introduced in a self-consistent way. The interdisciplinary fields between quantum information and other fields of physics such as condensed matter physics and statistical physics are also explored in terms of the topological quantum codes. This book thus provides the first comprehensive description of the whole picture of topological quantum codes and quantum computation with them.

  5. Association of PSA, free-PSA and testosteron levels in serum of patients with benign prostate hyperplasia (BPH) and prostate cancer

    International Nuclear Information System (INIS)

    Wiwin Mailana; Kristina Dwi P; Sri Insani WW; Puji Widayati

    2015-01-01

    Prostate cancer screening can be done by measuring the concentration levels of PSA, free-PSA and testosterone in serum that examined with radioimmunoassay (RIA). A total of 30 patients of 45-81 years old had enrolled in this study and were taken their venous blood. The aim of research is to know the relationship between PSA and testosterone free-PSA with BPH and prostate cancer. Results showed that there was no correlation between age with BPH and prostate cancer (p = 0.06), but there is a relationship between PSA with BPH and prostate cancer (p = 0.002), the relationship between free-PSA with BPH and prostate cancer (p = 0.001). No correlation was found between PSA ratio with BPH and prostate cancer as well as the absence of a relationship between testosterone with BPH and prostate cancer (p = 0.924). (author)

  6. Development of the SKI Handbook for reviewing PSA after the review of the of a PSA level 2 study

    International Nuclear Information System (INIS)

    Lindholm, Ilona; Sairanen, Risto

    2003-02-01

    A review of the Oskarshamn 2 Level 2 PSA has been conducted by VTT Processes. One objective of the review was validation and development of Tillsynshandbok PSA applying it to Oskarshamn 2 PSA Level 2 study. The review was based on the PSA Level 2 documentation: the main report, the supporting reports on containment success criteria and release calculations with the MAAP4 code, and five phenomenological reports for selected specific questions. The main result of the phenomenological analyses is that none of the phenomena considered contributes to the conditional failure probability of the Oskarshamn 2 containment in severe accidents. The project was conducted as a set of separate studies and the project quality assurance has also focused on one part at the time. As such, the quality assurance is adequate. A high level QA ensuring that all separate studies and analysis steps use same assumptions seems to be missing. Results from the phenomenology reports are not always transferred to accident analyses and vice versa. There is no specific discussion of uncertainty or sensitivity analyses. In general, the number of sensitivity analyses could be larger. Such should have been provided for sequences or phenomena that could result in early or unmitigated release. Examples are pressure vessel failure at high pressure, the effect of larger hydrogen production, and the key assumptions used for steam explosion and direct containment heating. Suggestions for additional sensitivity studies have been given in discussion of phenomenological reports. The project documentation is generally good. Missing information is usually associated with transfer of results from one study to another. It can be assumed that the information exists also in this cases but has not been documented in the reports above. Documentation of the containment event trees and the assumptions used for them could be more detailed, maybe similar to the approach used in the Appendix of this report. More effort

  7. Study of possibility using LANL PSA-methodology for accident probability RBMK researches

    International Nuclear Information System (INIS)

    Petrin, S.V.; Yuferev, V.Y.; Zlobin, A.M.

    1995-01-01

    The reactor facility probabilistic safety analysis methodologies are considered which are used at U.S. LANL and RF NIKIET. The methodologies are compared in order to reveal their similarity and differences, determine possibilities of using the LANL technique for RBMK type reactor safety analysis. It is found that at the PSA-1 level the methodologies practically do not differ. At LANL the PHA, HAZOP hazards analysis methods are used for more complete specification of the accounted initial event list which can be also useful at performance of PSA for RBMK. Exchange of information regarding the methodology of detection of dependent faults and consideration of human factor impact on reactor safety is reasonable. It is accepted as useful to make a comparative study result analysis for test problems or PSA fragments using various computer programs employed at NIKIET and LANL

  8. SURE: a system of computer codes for performing sensitivity/uncertainty analyses with the RELAP code

    International Nuclear Information System (INIS)

    Bjerke, M.A.

    1983-02-01

    A package of computer codes has been developed to perform a nonlinear uncertainty analysis on transient thermal-hydraulic systems which are modeled with the RELAP computer code. Using an uncertainty around the analyses of experiments in the PWR-BDHT Separate Effects Program at Oak Ridge National Laboratory. The use of FORTRAN programs running interactively on the PDP-10 computer has made the system very easy to use and provided great flexibility in the choice of processing paths. Several experiments simulating a loss-of-coolant accident in a nuclear reactor have been successfully analyzed. It has been shown that the system can be automated easily to further simplify its use and that the conversion of the entire system to a base code other than RELAP is possible

  9. NRC regulatory uses of PSA

    International Nuclear Information System (INIS)

    Murley, T.E.

    1991-01-01

    The publication in 1975 of WASH-1400, with its new probabilistic safety assessment (PSA) methodology, had the effect of presenting a pair of eyeglasses to a man with poor eyesight. Suddenly, it gave us a view of nuclear safety with a new clarity, and it allowed us to sort out the important safety issues from the unimportant. In the intervening years, PSA insights have permeated the fabric of nearly all our safety judgments. This acceptance can be seen from the following list of broad areas where the Nuclear Regulatory Commission (NRC) staff uses PSA insights and methodology: evaluating the safety significance of operating events and recommending safety improvements where warranted; requesting licensees to systematically look for design vulnerabilities in each operating reactor; evaluating the safety significance of design weaknesses or non-compliances when judging the time frame for necessary improvements; conducting sensitivity analyses to judge where safety improvements are most effective; assessing the relative safety benefits of design features for future reactors. In judging where PSA methodology can be improved to give better safety insights, it is believed that the following areas need more attention: better modeling of cognitive errors; more comprehensive modeling of accident sequences initiated from conditions other than full power; more comprehensive modeling of inter-system loss of coolant accident (ISLOCA) sequences. Although PSA is widely used in the staff's regulatory activities, the NRC deliberately chooses not to include probabilistic prescriptions in regulations or guidance documents. The staff finds the bottom line risk estimates to be one of the least reliable products of a PSA. The reason for this view is that PSA cannot adequately address cognitive errors nor assess the effects of a pervasive poor safety attitude

  10. Post treatment PSA nadirs support continuing dose escalation study in patients with pretreatment PSA levels >10 ng/ml, but not in those with PSA <10 NG/ML

    International Nuclear Information System (INIS)

    Herold, D.H.; Hanlon, A.L.; Movsas, B.; Hanks, G.E.

    1996-01-01

    Purpose: We have recently shown that ICRU reporting point radiation doses above 71 Gy are not associated with improved bNED survival in prostate cancer patients with pretreatment PSA level 20 ng/ml we found a strong correlation between dose and nadir values < 1.0 ng/ml (p=.003) as well as for nadir's < 0.5 ng/ml (p=.04). This dose/nadir effect held at several dose levels, but 74 Gy for nadir values < 1.0 ng/ml and 72 Gy for nadir's < 0.5 ng/ml remained the most significant. 32% of these patients achieved a nadir < 1.0ng/ml and 15% < 0.5ng/ml. Conclusions: This analysis provides strong additional support that patients with pretreatment PSA values of < 10 ng/ml do not benefit from dose escalation beyond an ICRU reporting point dose of 71 Gy. For patients with pretreatment PSA's of 10-19.9 ng/ml there is no dose/nadir response evaluated at a nadir of 1.0 ng/ml; however, there is a borderline effect observed at a nadir of 0.5 ng/ml. Patients with pretreatment PSA's of 20 ng/ml or greater clearly benefit from higher doses as evaluated by PSA nadirs of 1.0 ng/ml, and 0.5 ng/ml. These studies support the continued investigation of dose escalation in treating patients with PSA levels over 10 ng/ml, they do not support continued investigation of dose escalation beyond 71 Gy in patients with pretreatment PSA levels < 10 ng/ml. The failure to demonstrate any dose response for the low PSA group and the finding of only a borderline effect for the intermediate PSA group may be influenced by the relatively small number of patients in our series treated to doses < 70 Gy and the fact that none of our patients were treated to doses below 65.98 Gy. The lower limit of acceptible dose has yet to be defined

  11. Two-phase computer codes for zero-gravity applications

    International Nuclear Information System (INIS)

    Krotiuk, W.J.

    1986-10-01

    This paper discusses the problems existing in the development of computer codes which can analyze the thermal-hydraulic behavior of two-phase fluids especially in low gravity nuclear reactors. The important phenomenon affecting fluid flow and heat transfer in reduced gravity is discussed. The applicability of using existing computer codes for space applications is assessed. Recommendations regarding the use of existing earth based fluid flow and heat transfer correlations are made and deficiencies in these correlations are identified

  12. PSA - a tool for the nuclear safety

    International Nuclear Information System (INIS)

    Himanen, R.

    1992-01-01

    The PSA-model for BWR-type reactors of Finnish power company, Teollisuuden Voima Oy (TVO) was finished in year 1989. This basic PSA model included all safety systems, normal operating systems and auxiliary systems. Today TVO is working to enlarge the PSA to level 2 (environmental effects, for the fires, for the floodings and the outages). The TVO's experiences has been showed the PSA an useful tool for the developing the safety of BWR's (orig.)

  13. Computer codes for designing proton linear accelerators

    International Nuclear Information System (INIS)

    Kato, Takao

    1992-01-01

    Computer codes for designing proton linear accelerators are discussed from the viewpoint of not only designing but also construction and operation of the linac. The codes are divided into three categories according to their purposes: 1) design code, 2) generation and simulation code, and 3) electric and magnetic fields calculation code. The role of each category is discussed on the basis of experience at KEK (the design of the 40-MeV proton linac and its construction and operation, and the design of the 1-GeV proton linac). We introduce our recent work relevant to three-dimensional calculation and supercomputer calculation: 1) tuning of MAFIA (three-dimensional electric and magnetic fields calculation code) for supercomputer, 2) examples of three-dimensional calculation of accelerating structures by MAFIA, 3) development of a beam transport code including space charge effects. (author)

  14. DISP1 code

    International Nuclear Information System (INIS)

    Vokac, P.

    1999-12-01

    DISP1 code is a simple tool for assessment of the dispersion of the fission product cloud escaping from a nuclear power plant after an accident. The code makes it possible to tentatively check the feasibility of calculations by more complex PSA3 codes and/or codes for real-time dispersion calculations. The number of input parameters is reasonably low and the user interface is simple enough to allow a rapid processing of sensitivity analyses. All input data entered through the user interface are stored in the text format. Implementation of dispersion model corrections taken from the ARCON96 code enables the DISP1 code to be employed for assessment of the radiation hazard within the NPP area, in the control room for instance. (P.A.)

  15. Generation of monoclonal antibodies against prostate specific antigen (PSA) for the detection of PSA and its purification; Generación de anticuerpos monoclonales contra el antígeno específico de próstata (PSA) para la detección del PSA y su purificación

    Energy Technology Data Exchange (ETDEWEB)

    Acevedo Castro, Boris Ernesto [Centro de Ingeniería Genética y Biotecnología, CIGB, La Habana (Cuba)

    2012-07-01

    The prostate cancer in Cuba is a problem of health (2672 diagnosed cases and 2769 deaths in 2007). Various diagnostic methods have been implemented for the detection and management of this disease, emphasizing among them (PSA) prostate-specific antigen serological determination. At this work was generated and characterized a panel of 11 antibodies (AcMs) monoclonal IgG1 detected with high affinity described major epitopes of the PSA, both in solution and attached to the test plate. From the panel obtained AcMs was the standardization of an essay type ELISA for the detection of serum total PSA (associated and free) equimolar, based on antibody monoclonal CB-PSA.4 in the coating and the CB-PSA.9 coupled with biotin as liner, with a detection limit of 0.15 ng/mL. Similarly, standardized system for detection in serum free PSA, based on the AcMs CB-PSA.4 (coating) and CB-PSA.2 coupled with biotin (liner), with a detection limit of 0.5 ng/mL. Finally, with the purpose of using PSA as standard in trials type ELISA, developed a simple method of inmunopurificación based on the AcM, CB-PSA.2, which was obtained the PSA with a purity exceeding 90%. Immunoassay Centre on the basis of the AcMs panel and the results of this study, developed and recorded two diagnostic systems for the detection of PSA in human serum. (author)

  16. PSA methodology

    Energy Technology Data Exchange (ETDEWEB)

    Magne, L

    1997-12-31

    The purpose of this text is first to ask a certain number of questions on the methods related to PSAs. Notably we will explore the positioning of the French methodological approach - as applied in the EPS 1300{sup 1} and EPS 900{sup 2} PSAs - compared to other approaches (Part One). This reflection leads to more general reflection: what contents, for what PSA? This is why, in Part Two, we will try to offer a framework for definition of the criteria a PSA should satisfy to meet the clearly identified needs. Finally, Part Three will quickly summarize the questions approached in the first two parts, as an introduction to the debate. 15 refs.

  17. PET/CT with (18)F-choline after radical prostatectomy in patients with PSA ≤2 ng/ml. Can PSA velocity and PSA doubling time help in patient selection?

    Science.gov (United States)

    Chiaravalloti, Agostino; Di Biagio, Daniele; Tavolozza, Mario; Calabria, Ferdinando; Schillaci, Orazio

    2016-07-01

    To investigate the performance of (18)F-fluorocholine ((18)F-FCH) PET/CT in relation to the prostate-specific antigen (PSA) kinetic indexes, PSA doubling time (PSAdt) and PSA velocity (PSAve), in detecting recurrent prostate cancer (PC) in a selected population of patients treated with radical prostatectomy and with PSA ≤2 ng/ml. The study group comprised 79 patients (mean age 70 ± 7 years, range 58 - 77 years) who had been treated with radical surgery 30 to 90 months previously and with biochemical failure (defined as a measurable serum PSA level) who were evaluated with (18)F-FCH PET/CT. In order to establish the optimal threshold for PSAdt and PSAve, the diagnostic performance of PSA, PSAdt and PSAve were compared by receiver operating characteristic analysis. In the population examined, PSA (mean ± SD) was 1.37 ± 0.44 ng/ml (range 0.21 - 2 ng/ml) before PET/CT examination, PSAdt was 10.04 ± 16.67 months and PSAve was 2.75 ± 3.11 ng/ml per year. (18)F-FCH PET/CT was positive in 44 patients (55 %). PSAve and PSAdt were significantly different between patients with a positive and a negative (18)F-FCH PET/CT scan. Thresholds of 6 months for PSAdt and 1 ng/ml per year for PSAve were selected. For PSAdt ≤6 months the detection rate (DR) was 65 %, and for PSAve >1 ng/ml per year the DR was 67 %. PSA values were not significantly different between patients with a positive and a negative PET/CT scan. The results of our study suggest that (18)F-FCH PET/CT could be considered for the evaluation of patients with biochemical recurrence of PC and with low PSA levels. Fast PSA kinetics could be useful in the selection of these patients.

  18. A compendium of computer codes in fault tree analysis

    International Nuclear Information System (INIS)

    Lydell, B.

    1981-03-01

    In the past ten years principles and methods for a unified system reliability and safety analysis have been developed. Fault tree techniques serve as a central feature of unified system analysis, and there exists a specific discipline within system reliability concerned with the theoretical aspects of fault tree evaluation. Ever since the fault tree concept was established, computer codes have been developed for qualitative and quantitative analyses. In particular the presentation of the kinetic tree theory and the PREP-KITT code package has influenced the present use of fault trees and the development of new computer codes. This report is a compilation of some of the better known fault tree codes in use in system reliability. Numerous codes are available and new codes are continuously being developed. The report is designed to address the specific characteristics of each code listed. A review of the theoretical aspects of fault tree evaluation is presented in an introductory chapter, the purpose of which is to give a framework for the validity of the different codes. (Auth.)

  19. Computer code ANISN multiplying media and shielding calculation II. Code description (input/output)

    International Nuclear Information System (INIS)

    Maiorino, J.R.

    1990-01-01

    The user manual of the ANISN computer code describing input and output subroutines is presented. ANISN code was developed to solve one-dimensional transport equation for neutron or gamma rays in slab, sphere or cylinder geometry with general anisotropic scattering. The solution technique is the discrete ordinate method. (M.C.K.)

  20. The correlation of PSA nadir and biochemical freedom from cancer after external beam treatment: effects of stage, grade and pretreatment PSA groupings

    International Nuclear Information System (INIS)

    Pinover, W.H.; Hanlon, A.L.; Lee, W.R.; Hanks, G.E.

    1996-01-01

    Purpose: This study demonstrates the correlation of various post-irradiation PSA nadirs with long term biochemical freedom from disease (bNED) survival in patients treated mainly with conformal external beam radiation therapy. It also shows the effects of various groupings of pretreatment (prerx) PSA level, stage, and Gleason score on the rate of achieving a favorable PSA nadir. Materials and Methods: Three hundred forty patients with known pretreatment PSA, >2 years followup treated with radiation alone (278 conformal, 62 conventional) are reported. The median followup is 41 months (range 24 to 96 mos.). Patient grouping by pretreatment PSA levels are <10 ng/ml (143 patients), 10-19.9 ng/ml (108 patients), ≥20 ng/ml (89 patients); by palpation stage are T1C,2AB (240 patients) and T2C,3,4 (100 patients); and by differentiation are Gleason 2-4 (108 patients), Gleason 5-7 (221 patients), Gleason 8-10 (11 patients). The PSA nadir response is given for all patients, and for each of the above prerx groupings. The 5 year actuarial bNED survival is determined for all patients by PSA nadir. Biochemical failure is a PSA ≥1.5 ng/ml and rising on two consecutive measures. Multivariate analysis (MVA) is performed to determine factors predictive of favorable PSA nadir response and predictive of bNED survival. Results: The PSA nadir responses and 5 year bNED survival rates are shown in the table for all patients according to PSA nadir. 66% of patients achieved a favorable nadir (<1.0 ng/ml) which was associated with a 75%-87% 5 year bNED rate, while 34% achieved an unfavorable nadir associated with an 18-32% bNED survival rate at 5 years. The figure illustrates the dramatic separation in outcome associated with the nadir response. The table also illustrates the fraction of patients that achieve various nadir levels subdivided by prerx PSA level, palpation stage and Gleason score. A favorable PSA nadir is obtained in 90%, 63%, and 31% of patients with a prerx PSA <10, 10

  1. Purification of PSA from human semen

    International Nuclear Information System (INIS)

    Venkatesh, M.

    1997-01-01

    Full text: 1. Human seminal plasma collected from many volunteers are pooled and passed through a column of phenyl sepharose equilibrated with 1.25 M ammonium sulphate. Elution is carried out with 1.25 M ammonium sulphate initially, to remove the bulk non-adsorbing proteins. Gradient elution of the absorbed proteins with 0.01 M Tris-HCl, 0.25 M NaCl, pH 7.0 buffer gives a sharp peak containing PSA. At each stage, PSA has to be identified by an independent method such as immunodiffusion or an immunoassay. 2. The absorbed protein peak containing PSA is then lyophilised, redissolved in Tris-HCl buffer and chromatographed in a Superdex-75 or Sephadex-75 column. The absorbed proteins elute out as multiple peaks and PSA is eluted as a sharp peak.At each stage, PSA has to be identified by an independent method such as immunodiffusion or an immunoassay. 3. Step 2 is repeated for better purity. 4. The PSA peak is lyophilised, dissolved in Tris-HCl buffer without NaCl and further purified on an ion exchange column (either anion or cation exchange columns such as DEAE Sephadex or CM-Sephadex or Mono Q). Gradient elution using Tris-HCl buffer without NaCl and Tris-HCl buffer with 0.25 M NaCl resulted in a sharp pure PSA peak (homogenous, sharp single band on SDS-PAGE). This procedure is based on that reported by Wang et al., Oncology, 39,1,1982

  2. Evaluation of the FRAPCON-3 Computer Code

    Energy Technology Data Exchange (ETDEWEB)

    Jernkvist, Lars Olof; Massih, Ali [Quantum Technologies AB, Uppsala (Sweden)

    2002-03-01

    The FRAPCON-3 computer code has been evaluated with respect to its applicability, modeling capability, user friendliness, source code structure and supporting experimental database. The code is intended for thermo-mechanical analyses of light water reactor nuclear fuel rods under steady-state operational conditions and moderate power excursions. It is applicable to both boiling- and pressurized water reactor fuel rods with UO{sub 2} fuel, ranging up to about 65 MWd/kg U in rod average burnup. The models and numerical methods in FRAPCON-3 are relatively simple, which makes the code transparent and also fairly easy to modify and extend for the user. The fundamental equations for heat transfer, structural analysis and fuel fission gas release are solved in one-dimensional (radial) and stationary (time-independent) form, and interaction between axial segments of the rod is confined to calculations of coolant axial flow and rod internal gas pressure. The code is fairly easy to use; fuel rod design data and time histories of fuel rod power and coolant inlet conditions are input via a single text file, and the corresponding calculated variation with time of important fuel rod parameters are printed to a single output file in textual form. The results can also be presented in graphical form through an interface to the general graphics program xmgr. FRAPCON-3 also provides the possibility to export calculated results to the transient fuel rod analysis code FRAPTRAN, where the data can be used as burnup-dependent initial conditions to a postulated transient. Most of the source code to FRAPCON-3 is written in Fortran-IV, which is an archaic, non-standard dialect of the Fortran programming language. Since Fortran-IV is not accepted by all compilers for the latest standard of the language, Fortran-95, there is a risk that the source code must be partly rewritten in the future. Documentation of the code comprises (i) a general code description, which briefly presents models

  3. Evaluation of the FRAPCON-3 Computer Code

    International Nuclear Information System (INIS)

    Jernkvist, Lars Olof; Massih, Ali

    2002-03-01

    The FRAPCON-3 computer code has been evaluated with respect to its applicability, modeling capability, user friendliness, source code structure and supporting experimental database. The code is intended for thermo-mechanical analyses of light water reactor nuclear fuel rods under steady-state operational conditions and moderate power excursions. It is applicable to both boiling- and pressurized water reactor fuel rods with UO 2 fuel, ranging up to about 65 MWd/kg U in rod average burnup. The models and numerical methods in FRAPCON-3 are relatively simple, which makes the code transparent and also fairly easy to modify and extend for the user. The fundamental equations for heat transfer, structural analysis and fuel fission gas release are solved in one-dimensional (radial) and stationary (time-independent) form, and interaction between axial segments of the rod is confined to calculations of coolant axial flow and rod internal gas pressure. The code is fairly easy to use; fuel rod design data and time histories of fuel rod power and coolant inlet conditions are input via a single text file, and the corresponding calculated variation with time of important fuel rod parameters are printed to a single output file in textual form. The results can also be presented in graphical form through an interface to the general graphics program xmgr. FRAPCON-3 also provides the possibility to export calculated results to the transient fuel rod analysis code FRAPTRAN, where the data can be used as burnup-dependent initial conditions to a postulated transient. Most of the source code to FRAPCON-3 is written in Fortran-IV, which is an archaic, non-standard dialect of the Fortran programming language. Since Fortran-IV is not accepted by all compilers for the latest standard of the language, Fortran-95, there is a risk that the source code must be partly rewritten in the future. Documentation of the code comprises (i) a general code description, which briefly presents models

  4. Independent peer review of nuclear safety computer codes

    International Nuclear Information System (INIS)

    Boyack, B.E.; Jenks, R.P.

    1993-01-01

    A structured, independent computer code peer-review process has been developed to assist the US Nuclear Regulatory Commission (NRC) and the US Department of Energy in their nuclear safety missions. This paper describes a structured process of independent code peer review, benefits associated with a code-independent peer review, as well as the authors' recent peer-review experience. The NRC adheres to the principle that safety of plant design, construction, and operation are the responsibility of the licensee. Nevertheless, NRC staff must have the ability to independently assess plant designs and safety analyses submitted by license applicants. According to Ref. 1, open-quotes this requires that a sound understanding be obtained of the important physical phenomena that may occur during transients in operating power plants.close quotes The NRC concluded that computer codes are the principal products to open-quotes understand and predict plant response to deviations from normal operating conditionsclose quotes and has developed several codes for that purpose. However, codes cannot be used blindly; they must be assessed and found adequate for the purposes they are intended. A key part of the qualification process can be accomplished through code peer reviews; this approach has been adopted by the NRC

  5. Pattern of Prostate-Specific Antigen (PSA) Failure Dictates the Probability of a Positive Bone Scan in Patients With an Increasing PSA After Radical Prostatectomy

    Science.gov (United States)

    Dotan, Zohar A.; Bianco, Fernando J.; Rabbani, Farhang; Eastham, James A.; Fearn, Paul; Scher, Howard I.; Kelly, Kevin W.; Chen, Hui-Ni; Schöder, Heiko; Hricak, Hedvig; Scardino, Peter T.; Kattan, Michael W.

    2007-01-01

    Purpose Physicians often order periodic bone scans (BS) to check for metastases in patients with an increasing prostate-specific antigen (PSA; biochemical recurrence [BCR]) after radical prostatectomy (RP), but most scans are negative. We studied patient characteristics to build a predictive model for a positive scan. Patients and Methods From our prostate cancer database we identified all patients with detectable PSA after RP. We analyzed the following features at the time of each bone scan for association with a positive BS: preoperative PSA, time to BCR, pathologic findings of the RP, PSA before the BS (trigger PSA), PSA kinetics (PSA doubling time, PSA slope, and PSA velocity), and time from BCR to BS. The results were incorporated into a predictive model. Results There were 414 BS performed in 239 patients with BCR and no history of androgen deprivation therapy. Only 60 (14.5%) were positive for metastases. In univariate analysis, preoperative PSA (P = .04), seminal vesicle invasion (P = .02), PSA velocity (P < .001), and trigger PSA (P < .001) predicted a positive BS. In multivariate analysis, only PSA slope (odds ratio [OR], 2.71; P = .03), PSA velocity (OR, 0.93; P = .003), and trigger PSA (OR, 1.022; P < .001) predicted a positive BS. A nomogram for predicting the bone scan result was constructed with an overfit-corrected concordance index of 0.93. Conclusion Trigger PSA, PSA velocity, and slope were associated with a positive BS. A highly discriminating nomogram can be used to select patients according to their risk for a positive scan. Omitting scans in low-risk patients could reduce substantially the number of scans ordered. PMID:15774789

  6. PSA, subjective probability and decision making

    International Nuclear Information System (INIS)

    Clarotti, C.A.

    1989-01-01

    PSA is the natural way to making decisions in face of uncertainty relative to potentially dangerous plants; subjective probability, subjective utility and Bayes statistics are the ideal tools for carrying out a PSA. This paper reports that in order to support this statement the various stages of the PSA procedure are examined in detail and step by step the superiority of Bayes techniques with respect to sampling theory machinery is proven

  7. User's manual of SECOM2: a computer code for seismic system reliability analysis

    International Nuclear Information System (INIS)

    Uchiyama, Tomoaki; Oikawa, Tetsukuni; Kondo, Masaaki; Tamura, Kazuo

    2002-03-01

    This report is the user's manual of seismic system reliability analysis code SECOM2 (Seismic Core Melt Frequency Evaluation Code Ver.2) developed at the Japan Atomic Energy Research Institute for systems reliability analysis, which is one of the tasks of seismic probabilistic safety assessment (PSA) of nuclear power plants (NPPs). The SECOM2 code has many functions such as: Calculation of component failure probabilities based on the response factor method, Extraction of minimal cut sets (MCSs), Calculation of conditional system failure probabilities for given seismic motion levels at the site of an NPP, Calculation of accident sequence frequencies and the core damage frequency (CDF) with use of the seismic hazard curve, Importance analysis using various indicators, Uncertainty analysis, Calculation of the CDF taking into account the effect of the correlations of responses and capacities of components, and Efficient sensitivity analysis by changing parameters on responses and capacities of components. These analyses require the fault tree (FT) representing the occurrence condition of the system failures and core damage, information about response and capacity of components and seismic hazard curve for the NPP site as inputs. This report presents the models and methods applied in the SECOM2 code and how to use those functions. (author)

  8. Radiological impact assessment in Malaysia using RESRAD computer code

    International Nuclear Information System (INIS)

    Syed Hakimi Sakuma Syed Ahmad; Khairuddin Mohamad Kontol; Razali Hamzah

    1999-01-01

    Radiological Impact Assessment (RIA) can be conducted in Malaysia by using the RESRAD computer code developed by Argonne National Laboratory, U.S.A. The code can do analysis to derive site specific guidelines for allowable residual concentrations of radionuclides in soil. Concepts of the RIA in the context of waste management concern in Malaysia, some regulatory information and assess status of data collection are shown. Appropriate use scenarios and site specific parameters are used as much as possible so as to be realistic so that will reasonably ensure that individual dose limits and or constraints will be achieved. Case study have been conducted to fulfil Atomic Energy Licensing Board (AELB) requirements where for disposal purpose the operator must be required to carry out. a radiological impact assessment to all proposed disposals. This is to demonstrate that no member of public will be exposed to more than 1 mSv/year from all activities. Results obtained from analyses show the RESRAD computer code is able to calculate doses, risks, and guideline values. Sensitivity analysis by the computer code shows that the parameters used as input are justified so as to improve confidence to the public and the AELB the results of the analysis. The computer code can also be used as an initial assessment to conduct screening assessment in order to determine a proper disposal site. (Author)

  9. A DOE Computer Code Toolbox: Issues and Opportunities

    International Nuclear Information System (INIS)

    Vincent, A.M. III

    2001-01-01

    The initial activities of a Department of Energy (DOE) Safety Analysis Software Group to establish a Safety Analysis Toolbox of computer models are discussed. The toolbox shall be a DOE Complex repository of verified and validated computer models that are configuration-controlled and made available for specific accident analysis applications. The toolbox concept was recommended by the Defense Nuclear Facilities Safety Board staff as a mechanism to partially address Software Quality Assurance issues. Toolbox candidate codes have been identified through review of a DOE Survey of Software practices and processes, and through consideration of earlier findings of the Accident Phenomenology and Consequence Evaluation program sponsored by the DOE National Nuclear Security Agency/Office of Defense Programs. Planning is described to collect these high-use codes, apply tailored SQA specific to the individual codes, and implement the software toolbox concept. While issues exist such as resource allocation and the interface among code developers, code users, and toolbox maintainers, significant benefits can be achieved through a centralized toolbox and subsequent standardized applications

  10. Parallel computing by Monte Carlo codes MVP/GMVP

    International Nuclear Information System (INIS)

    Nagaya, Yasunobu; Nakagawa, Masayuki; Mori, Takamasa

    2001-01-01

    General-purpose Monte Carlo codes MVP/GMVP are well-vectorized and thus enable us to perform high-speed Monte Carlo calculations. In order to achieve more speedups, we parallelized the codes on the different types of parallel computing platforms or by using a standard parallelization library MPI. The platforms used for benchmark calculations are a distributed-memory vector-parallel computer Fujitsu VPP500, a distributed-memory massively parallel computer Intel paragon and a distributed-memory scalar-parallel computer Hitachi SR2201, IBM SP2. As mentioned generally, linear speedup could be obtained for large-scale problems but parallelization efficiency decreased as the batch size per a processing element(PE) was smaller. It was also found that the statistical uncertainty for assembly powers was less than 0.1% by the PWR full-core calculation with more than 10 million histories and it took about 1.5 hours by massively parallel computing. (author)

  11. Utilization of KENO-IV computer code with HANSEN-ROACH library

    International Nuclear Information System (INIS)

    Lima Barros, M. de; Vellozo, S.O.

    1982-01-01

    Several analysis with KENO-IV computer code, which is based in the Monte Carlo method, and the cross section library HANSEN-ROACH, were done, aiming to present the more convenient form to execute criticality calculations with this computer code and this cross sections. (E.G.) [pt

  12. Comparison of SKIFS 2004:1 and Tillsynshandbok PSA against the ASME PRA Standard and European requirements on PSA

    International Nuclear Information System (INIS)

    Hellstroem, Per

    2005-04-01

    Requirements on PSA for risk informed applications are expressed in different international documents. The ASME PRA standard published in spring 2002 is one such document, PSA requirements are also expressed in the European Utility Requirements (EUR) for new reactors. The Swedish PSA requirements are provided in the Swedish regulators (SKI) statutes SKIFS 2004:1. SKI also has a review handbook for PSA activities (SKI report 2003:48). The review handbook is a support during review of the utilities PSA activities and the PSAs themselves. The review handbook expresses SKIs expectations by providing so called important aspects for both the PSA work and the PSAs, A comparison of SKIFS requirements and the important aspects in the Review handbook, on one side, and the requirements on PSA in EUR and ASME on the other side, is presented. The comparison shows a large difference in the level of detail in the different documents, where ASME is most detailed and specific. This is expected since the SKI review handbook not is a 'PSA guide' in the same way as the ASME PRA standard. A direct comparison of the ASME PRA standard requirements with the important aspects in the review handbook cannot answer the question which ASME capacity level that is achieved by a PSA meeting all important aspects. The conclusion is that it is not likely to achieve capacity level 2 and 3, since very few ASME level 3 attributes are explicitly expressed as important aspects, though many are expressed in general terms. The review handbook important aspects that are most similar to the ASME capacity level 1 attributes are initiating events, sequence analysis, and system analysis while less similarity is found for analysis of operator actions data analysis, quantification and containment analysis (level 2). Less similarity is found for capacity level 2 and 3. However, the number of additional ASME attributes on capacity level 2 and 3 are few. There are also important aspects in the review handbook that

  13. Heat Transfer treatment in computer codes for safety analysis

    International Nuclear Information System (INIS)

    Jerele, A.; Gregoric, M.

    1984-01-01

    Increased number of operating nuclear power plants has stressed importance of nuclear safety evaluation. For this reason, accordingly to regulatory commission request, safety analyses with computer codes are preformed. In this paper part of this thermohydraulic models dealing with wall-to-fluid heat transfer correlations in computer codes TRAC=PF1, RELAP4/MOD5, RELAP5/MOD1 and COBRA-IV is discussed. (author)

  14. Relationship of chronic histologic prostatic inflammation in biopsy specimens with serum isoform [-2]proPSA (p2PSA), %p2PSA, and prostate health index in men with a total prostate-specific antigen of 4-10 ng/ml and normal digital rectal examination.

    Science.gov (United States)

    Lazzeri, Massimo; Abrate, Alberto; Lughezzani, Giovanni; Gadda, Giulio Maria; Freschi, Massimo; Mistretta, Francesco; Lista, Giuliana; Fossati, Nicola; Larcher, Alessandro; Kinzikeeva, Ella; Buffi, Nicolòmaria; Dell'Acqua, Vincenzo; Bini, Vittorio; Montorsi, Francesco; Guazzoni, Giorgio

    2014-03-01

    To investigate the relationship between serum [-2]proPSA (p2PSA) and derivatives with chronic histologic prostatic inflammation (CHPI) in men undergoing prostate biopsy for suspected prostate cancer (PCa). This nested case-control study resulted from an observational prospective trial for the definition of sensibility, specificity, and accuracy of p2PSA, %p2PSA, and Beckman Coulter Prostate Health Index (PHI), in men undergoing prostate biopsy, with a total prostate-specific antigen (PSA) of 4-10 ng/mL and normal digital rectal examination. CHPI was the outcome of interest and defined as the presence of moderate to large infiltration of lymphomononuclear cells with interstitial and/or glandular disruption in absence of PCa. p2PSA, %p2PSA, and PHI were considered the index tests and compared with the established biomarker reference standard tests: tPSA, fPSA, %fPSA. Of 267 patients subjected to prostate biopsy, 73 (27.3%) patients were diagnosed with CHPI. Comparing CHPI with PCa patients, %p2PSA and PHI were found to be significantly lower, whereas fPSA and %fPSA were significantly higher. %p2PSA and PHI were the most accurate predictors of CHPI at biopsy, significantly outperforming tPSA, fPSA, and %fPSA. On the contrary, no significant differences were found in PSA, p2PSA, and derivatives between CHPI and benign prostatic hyperplasia (BPH) patients. Our findings showed that p2PSA, %p2PSA, and PHI values might discriminate PCa from CHPI or BPH, but not CHPI from BPH, in men with a total PSA 4-10 ng/mL and normal digital rectal examination. p2PSA isoform and its derivatives could be useful in clinical decision making to avoid unnecessary biopsies in patients with CHPI and elevated tPSA value. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. FLASH: A finite element computer code for variably saturated flow

    International Nuclear Information System (INIS)

    Baca, R.G.; Magnuson, S.O.

    1992-05-01

    A numerical model was developed for use in performance assessment studies at the INEL. The numerical model, referred to as the FLASH computer code, is designed to simulate two-dimensional fluid flow in fractured-porous media. The code is specifically designed to model variably saturated flow in an arid site vadose zone and saturated flow in an unconfined aquifer. In addition, the code also has the capability to simulate heat conduction in the vadose zone. This report presents the following: description of the conceptual frame-work and mathematical theory; derivations of the finite element techniques and algorithms; computational examples that illustrate the capability of the code; and input instructions for the general use of the code. The FLASH computer code is aimed at providing environmental scientists at the INEL with a predictive tool for the subsurface water pathway. This numerical model is expected to be widely used in performance assessments for: (1) the Remedial Investigation/Feasibility Study process and (2) compliance studies required by the US Department of Energy Order 5820.2A

  16. Computing the Feng-Rao distances for codes from order domains

    DEFF Research Database (Denmark)

    Ruano Benito, Diego

    2007-01-01

    We compute the Feng–Rao distance of a code coming from an order domain with a simplicial value semigroup. The main tool is the Apéry set of a semigroup that can be computed using a Gröbner basis.......We compute the Feng–Rao distance of a code coming from an order domain with a simplicial value semigroup. The main tool is the Apéry set of a semigroup that can be computed using a Gröbner basis....

  17. Development Of A Navier-Stokes Computer Code

    Science.gov (United States)

    Yoon, Seokkwan; Kwak, Dochan

    1993-01-01

    Report discusses aspects of development of CENS3D computer code, solving three-dimensional Navier-Stokes equations of compressible, viscous, unsteady flow. Implements implicit finite-difference or finite-volume numerical-integration scheme, called "lower-upper symmetric-Gauss-Seidel" (LU-SGS), offering potential for very low computer time per iteration and for fast convergence.

  18. Control rod computer code IAMCOS: general theory and numerical methods

    International Nuclear Information System (INIS)

    West, G.

    1982-11-01

    IAMCOS is a computer code for the description of mechanical and thermal behavior of cylindrical control rods for fast breeders. This code version was applied, tested and modified from 1979 to 1981. In this report are described the basic model (02 version), theoretical definitions and computation methods [fr

  19. PSA-based evaluation and rating of operational events

    International Nuclear Information System (INIS)

    Gomez Cobo, A.

    1997-01-01

    The presentation discusses the PSA-based evaluation and rating of operational events, including the following: historical background, procedures for event evaluation using PSA, use of PSA for event rating, current activities

  20. Updating the Psoriatic Arthritis (PsA) Core Domain Set: A Report from the PsA Workshop at OMERACT 2016.

    Science.gov (United States)

    Orbai, Ana-Maria; de Wit, Maarten; Mease, Philip J; Callis Duffin, Kristina; Elmamoun, Musaab; Tillett, William; Campbell, Willemina; FitzGerald, Oliver; Gladman, Dafna D; Goel, Niti; Gossec, Laure; Hoejgaard, Pil; Leung, Ying Ying; Lindsay, Chris; Strand, Vibeke; van der Heijde, Désirée M; Shea, Bev; Christensen, Robin; Coates, Laura; Eder, Lihi; McHugh, Neil; Kalyoncu, Umut; Steinkoenig, Ingrid; Ogdie, Alexis

    2017-10-01

    To include the patient perspective in accordance with the Outcome Measures in Rheumatology (OMERACT) Filter 2.0 in the updated Psoriatic Arthritis (PsA) Core Domain Set for randomized controlled trials (RCT) and longitudinal observational studies (LOS). At OMERACT 2016, research conducted to update the PsA Core Domain Set was presented and discussed in breakout groups. The updated PsA Core Domain Set was voted on and endorsed by OMERACT participants. We conducted a systematic literature review of domains measured in PsA RCT and LOS, and identified 24 domains. We conducted 24 focus groups with 130 patients from 7 countries representing 5 continents to identify patient domains. We achieved consensus through 2 rounds of separate surveys with 50 patients and 75 physicians, and a nominal group technique meeting with 12 patients and 12 physicians. We conducted a workshop and breakout groups at OMERACT 2016 in which findings were presented and discussed. The updated PsA Core Domain Set endorsed with 90% agreement by OMERACT 2016 participants included musculoskeletal disease activity, skin disease activity, fatigue, pain, patient's global assessment, physical function, health-related quality of life, and systemic inflammation, which were recommended for all RCT and LOS. These were important, but not required in all RCT and LOS: economic cost, emotional well-being, participation, and structural damage. Independence, sleep, stiffness, and treatment burden were on the research agenda. The updated PsA Core Domain Set was endorsed at OMERACT 2016. Next steps for the PsA working group include evaluation of PsA outcome measures and development of a PsA Core Outcome Measurement Set.

  1. Verification of thermal-hydraulic computer codes against standard problems for WWER reflooding

    International Nuclear Information System (INIS)

    Alexander D Efanov; Vladimir N Vinogradov; Victor V Sergeev; Oleg A Sudnitsyn

    2005-01-01

    Full text of publication follows: The computational assessment of reactor core components behavior under accident conditions is impossible without knowledge of the thermal-hydraulic processes occurring in this case. The adequacy of the results obtained using the computer codes to the real processes is verified by carrying out a number of standard problems. In 2000-2003, the fulfillment of three Russian standard problems on WWER core reflooding was arranged using the experiments on full-height electrically heated WWER 37-rod bundle model cooldown in regimes of bottom (SP-1), top (SP-2) and combined (SP-3) reflooding. The representatives from the eight MINATOM's organizations took part in this work, in the course of which the 'blind' and posttest calculations were performed using various versions of the RELAP5, ATHLET, CATHARE, COBRA-TF, TRAP, KORSAR computer codes. The paper presents a brief description of the test facility, test section, test scenarios and conditions as well as the basic results of computational analysis of the experiments. The analysis of the test data revealed a significantly non-one-dimensional nature of cooldown and rewetting of heater rods heated up to a high temperature in a model bundle. This was most pronounced at top and combined reflooding. The verification of the model reflooding computer codes showed that most of computer codes fairly predict the peak rod temperature and the time of bundle cooldown. The exception is provided by the results of calculations with the ATHLET and CATHARE codes. The nature and rate of rewetting front advance in the lower half of the bundle are fairly predicted practically by all computer codes. The disagreement between the calculations and experimental results for the upper half of the bundle is caused by the difficulties of computational simulation of multidimensional effects by 1-D computer codes. In this regard, a quasi-two-dimensional computer code COBRA-TF offers certain advantages. Overall, the closest

  2. Seismic PSA method for multiple nuclear power plants in a site

    Energy Technology Data Exchange (ETDEWEB)

    Hakata, Tadakuni [Nuclear Safety Commission, Tokyo (Japan)

    2007-07-15

    The maximum number of nuclear power plants in a site is eight and about 50% of power plants are built in sites with three or more plants in the world. Such nuclear sites have potential risks of simultaneous multiple plant damages especially at external events. Seismic probabilistic safety assessment method (Level-1 PSA) for multi-unit sites with up to 9 units has been developed. The models include Fault-tree linked Monte Carlo computation, taking into consideration multivariate correlations of components and systems from partial to complete, inside and across units. The models were programmed as a computer program CORAL reef. Sample analysis and sensitivity studies were performed to verify the models and algorithms and to understand some of risk insights and risk metrics, such as site core damage frequency (CDF per site-year) for multiple reactor plants. This study will contribute to realistic state of art seismic PSA, taking consideration of multiple reactor power plants, and to enhancement of seismic safety. (author)

  3. Thermohydraulic analysis of nuclear power plant accidents by computer codes

    International Nuclear Information System (INIS)

    Petelin, S.; Stritar, A.; Istenic, R.; Gregoric, M.; Jerele, A.; Mavko, B.

    1982-01-01

    RELAP4/MOD6, BRUCH-D-06, CONTEMPT-LT-28, RELAP5/MOD1 and COBRA-4-1 codes were successful y implemented at the CYBER 172 computer in Ljubljana. Input models of NPP Krsko for the first three codes were prepared. Because of the high computer cost only one analysis of double ended guillotine break of the cold leg of NPP Krsko by RELAP4 code has been done. BRUCH code is easier and cheaper for use. Several analysis have been done. Sensitivity study was performed with CONTEMPT-LT-28 for double ended pump suction break. These codes are intended to be used as a basis for independent safety analyses. (author)

  4. The SEDA computer code and its utilization for Angra 1

    International Nuclear Information System (INIS)

    Fernandes Filho, T.L.

    1988-11-01

    The implementation of SEDA 2.0 computer code, developed at Ezeiza Atomic Center, Argentine for Angra 1 reactor is described. The SEDA code gives an estimate for radiological consequences of nuclear accidents with release of radiactive materials for the environment. This code is now available for an IBM PC-XT. The computer environment, the files used, data, the programining structure and the models used are presented. The input data and results for two sample case are described. (author) [pt

  5. Achievement of the level 1 PSA in support to the CEA 2400 MWth gas-cooled fast reactor

    International Nuclear Information System (INIS)

    Balmain, M.; Bassi, C.; Azria, P.

    2012-01-01

    Within Generation IV International Forum, the CEA has developed since 2006 a Level 1 PSA to support the design of the 2400 MWth GFR (Gas-cooled Fast Reactor). A first period, with insights published in 2008, consisted in a model with few initiators representative of medium and high pressure situations, those used for the deterministic design of the Decay Heat Removal (DHR) dedicated loops. In a second period, an iterative work reached the probabilistic targets used for generation III reactors, with prior use of normal loops, and increase of DHR reliability in high pressure conditions. The PSA team covered all the internal initiators, and supported the design of components with instrumentation and control and electrical supplies, and the shutdown operating modes of secondary, tertiary circuits, with possible re-alignment to dedicated DHR loops. Besides, the completed PSA integrated more realistic success criteria than the preliminary model and than the deterministic approach, thanks to CATHARE2 code. In case of loss of Forced Convection, the probability of success of the Natural Convection DHR was assessed by a reliability method for passive systems. The paper underlines the PSA methodology knowledge from the EDF expertise, the improvements co-developed with CEA, and the iteration design-PSA-design. (authors)

  6. Low Power Shutdown PSA for CANDU Type Plants

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Yeon Kyoung; Kim, Myung Su [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    KHNP also have concentrated on full power PSA. Some recently constructed OPR1000 type plants and APR1400 type plants have performed the low power and shutdown (LPSD) PSA. The purpose of LPSD PSA is to identify the main contributors on the accident sequences of core damage and to find the measure of safety improvement. After the Fukushima accident, Korean regulatory agency required the shutdown severe accident management guidelines (SSAMG) development for safety enhancement. For the reliability of SSAMG, KHNP should develop the LPSD PSA. Especially, the LPSD PSA for CANDU type plant had developed for the first time in Korea. This paper illustrates how the LPSD PSA for CANDU type developed and the core damage frequency (CDF) is different with that of full power PSA. KHNP performed LPSD PSA to develop the SSAMG after the Fukushima accidents. The results show that risk at the specific operation mode during outage is higher than that of full power operation. Also, the results indicated that recovery failure of class 4 power at the POS 5A, 5B contribute dominantly to the total CDF from importances analysis. LPSD PSA results such as CDF with initiating events and POSs, risk results with plant damage state, and containment failure probability and frequency with POSs can be used by inputs for developing the SSAMG.

  7. Interface between computational fluid dynamics (CFD) and plant analysis computer codes

    International Nuclear Information System (INIS)

    Coffield, R.D.; Dunckhorst, F.F.; Tomlinson, E.T.; Welch, J.W.

    1993-01-01

    Computational fluid dynamics (CFD) can provide valuable input to the development of advanced plant analysis computer codes. The types of interfacing discussed in this paper will directly contribute to modeling and accuracy improvements throughout the plant system and should result in significant reduction of design conservatisms that have been applied to such analyses in the past

  8. Development of a Computer Code for the Estimation of Fuel Rod Failure

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, I.H.; Ahn, H.J. [Korea Electric Power Research Institute, Daejeon (Korea, Republic of)

    1997-12-31

    Much research has already been performed to obtain the information on the degree of failed fuel rods from the primary coolant activities of operating PWRs in the last few decades. The computer codes that are currently in use for domestic nuclear power plants, such as CADE code and ABB-CE codes developed by Westinghouse and ABB-CE, respectively, still give significant overall errors in estimating the failed fuel rods. In addition, with the CADE code, it is difficult to predict the degree of fuel rod failures during the transient period of nuclear reactor operation, where as the ABB-CE codes are relatively more difficult to use for end-users. In particular, the rapid progresses made recently in the area of the computer hardware and software systems that their computer programs be more versatile and user-friendly. While the MS windows system that is centered on the graphic user interface and multitasking is now in widespread use, the computer codes currently employed at the nuclear power plants, such as CADE and ABB-CE codes, can only be run on the DOS system. Moreover, it is desirable to have a computer code for the fuel rod failure estimation that can directly use the radioactivity data obtained from the on-line monitoring system of the primary coolant activity. The main purpose of this study is, therefore, to develop a Windows computer code that can predict the location, the number of failed fuel rods,and the degree of failures using the radioactivity data obtained from the primary coolant activity for PWRs. Another objective is to combine this computer code with the on-line monitoring system of the primary coolant radioactivity at Kori 3 and 4 operating nuclear power plants and enable their combined use for on-line evaluation of the number and degree of fuel rod failures. (author). 49 refs., 85 figs., 30 tabs.

  9. Radiometric assays for the measurement of PSA

    International Nuclear Information System (INIS)

    Venkatesh, M.

    1997-01-01

    Prostate Specific Antigen, a serine protease enzyme, of M.W. ∼ 26-33 kDa, is widely considered to be a very useful marker for prostate cancer. It satisfies nearly all the requirements of an ideal 'Tumour Marker' and has hence attracted a lot of attention in the past decade. PSA is present in multiple forms in serum, with an appreciable fraction bound to the protease inhibitor α-1-antichymotrypsin (ACT) and to a small extent to other proteins such as α-2-macroglobulin (AMG) leaving the rest in the free form. The total PSA levels have been reported to have 80% sensitivity and 60% specificity towards the detection of prostate cancer. The lack of specificity occurs mainly due to the high levels of t-PSA in benign prostatic hypertrophy(BPH) apart from the cancer. The concept of free PSA has been introduced in the recent past and the ratio of free/total PSA levels have been shown to be advantageous in the differential diagnosis of BPH from prostate cancer. The f/t ratio is considered to be particularly useful in the grey zones of decision making (t-PSA levels 4-20 ng/mL). The need for the development of assays for total and free PSA is felt due to: a. the high incidence of prostate cancers being detected currently; b. the high cost of tests (higher for free PSA assay, and the cost becomes an important parameter when a patient has to be regularly monitored after therapy) that is not affordable for many patients; c. the potential for research in the area of prostate cancer management where the PSA (total and free) assays will be of great help

  10. Methods and results of a PSA level 2 for a German BWR of the 900 MWe class

    International Nuclear Information System (INIS)

    Loffler, H.; Sonnenkalb, M.

    2006-01-01

    On behalf of the federal Ministry for Environment, Nature Conservation and Reactor Safety (BMU) GRS has performed a PSA level 2 for a BWR type 69 NPP of the 900 MWe class, equipped with a N 2 inerted steel containment and a pressure suppression system. Integral deterministic accident analyses have been performed with the computer code MELCOR 1.8.5. Additional analyses have been done for those events and phenomena which are not or not sufficiently covered by MELCOR. The probabilistic event tree analysis begins with the core damage states received from PSA level 1, and it ends with the definition of release categories and the determination of their frequencies. Uncertainties about the frequency of core damage states and about events during the accident progression are taken into account by means of Monte Carlo simulations. If there is a core damage state there is a high probability (>50 %) for a very high and rapid release of radionuclides into the environment. This high conditional probability is due to the very low probability to retain a partly destroyed core inside the reactor pressure vessel (RPV) and because the containment almost certainly fails at the bottom of the control rod drives room after melt release from the failed RPV. (authors)

  11. Status of the PSA use in the Czech regulatory process

    International Nuclear Information System (INIS)

    Dusek, J.

    1994-01-01

    A review of previous probabilistic safety assessment (PSA) activities initiated by regulatory body and preparation of the preliminary PSA study and final PSA study (released in January 1994) for the nuclear power plant Dukovany with WWER-440 type 213 reactor is described. A brief information about the NPP Temelin (with WWER-1000) PSA Study, shutdown and PSA risk monitor current activities for the NPP Dukovany, next PSA activities in 1994 and about planned PSA activities in future is attached. (author). 21 refs

  12. Workshop on PSA for New and Advanced Reactors

    International Nuclear Information System (INIS)

    2012-01-01

    This workshop was organized by the NEA Working Group on Risk Assessment (WGRISK). The key objective of the workshop was to share the current state-of-the art on the PSA (Probabilistic Safety Assessment) applied for new reactors and advanced reactors. Fifty experts from 13 countries and one international organization (IAEA) participated in the present workshop, and 35 technical papers were presented. The main topics of interest, discussed during the workshop, included the followings: regulatory aspects, risk-informed methods, technical aspects of the PSA for new and advanced reactors, hazards of PSA (internal and external), severe accident/source term/Level 2 PSA, and consequence analysis/Level 3 PSA. Among the technical aspects of the PSA, the assessment of the reliability of passive safety systems appears to be a recurrent issue

  13. Development of multipurpose regulatory PSA model

    International Nuclear Information System (INIS)

    Lee, Chang Ju; Sung, Key Yong; Kim, Hho Jung; Yang, Joon Eon; Ha, Jae Joo

    2004-01-01

    Generally, risk information for nuclear facilities comes from the results of Probabilistic safety assessment (PSA). PSA is a systematic tool to ensure the safety of nuclear facilities, since it is based on thorough and consistent application of probability models. In particular, the PSA has been widely utilized for risk-informed regulation (RIR), including various licensee-initiated risk-informed applications (RIA). In any regulatory decision, the main goal is to make a sound safety decision based on technically defensible information. Also, due to the increased public requests for giving a safety guarantee, the regulator should provide the visible means of safety. The use of PSA by the regulator can give the answer on this problem. Therefore, in order to study the applicability of risk information for regulatory safety management, it is a demanding task to prepare a well-established regulatory PSA model and tool. In 2002, KINS and KAERI together made a research cooperation to form a working group to develop the regulatory PSA model - so-called MPAS model. The MPAS stands for multipurpose probabilistic analysis of safety. For instance, a role of the MPAS model is to give some risk insights in the preparation of various regulatory programs. Another role of this model is to provide an independent risk information to the regulator during regulatory decision-making, not depending on the licensee's information

  14. Efficient Proximity Computation Techniques Using ZIP Code Data for Smart Cities †.

    Science.gov (United States)

    Murdani, Muhammad Harist; Kwon, Joonho; Choi, Yoon-Ho; Hong, Bonghee

    2018-03-24

    In this paper, we are interested in computing ZIP code proximity from two perspectives, proximity between two ZIP codes ( Ad-Hoc ) and neighborhood proximity ( Top-K ). Such a computation can be used for ZIP code-based target marketing as one of the smart city applications. A naïve approach to this computation is the usage of the distance between ZIP codes. We redefine a distance metric combining the centroid distance with the intersecting road network between ZIP codes by using a weighted sum method. Furthermore, we prove that the results of our combined approach conform to the characteristics of distance measurement. We have proposed a general and heuristic approach for computing Ad-Hoc proximity, while for computing Top-K proximity, we have proposed a general approach only. Our experimental results indicate that our approaches are verifiable and effective in reducing the execution time and search space.

  15. Efficient Proximity Computation Techniques Using ZIP Code Data for Smart Cities †

    Directory of Open Access Journals (Sweden)

    Muhammad Harist Murdani

    2018-03-01

    Full Text Available In this paper, we are interested in computing ZIP code proximity from two perspectives, proximity between two ZIP codes (Ad-Hoc and neighborhood proximity (Top-K. Such a computation can be used for ZIP code-based target marketing as one of the smart city applications. A naïve approach to this computation is the usage of the distance between ZIP codes. We redefine a distance metric combining the centroid distance with the intersecting road network between ZIP codes by using a weighted sum method. Furthermore, we prove that the results of our combined approach conform to the characteristics of distance measurement. We have proposed a general and heuristic approach for computing Ad-Hoc proximity, while for computing Top-K proximity, we have proposed a general approach only. Our experimental results indicate that our approaches are verifiable and effective in reducing the execution time and search space.

  16. The optimal timing to perform 18F/11C-choline PET/CT in patients with suspicion of relapse of prostate cancer: trigger PSA versus PSA velocity and PSA doubling time.

    Science.gov (United States)

    Calabria, Ferdinando; Rubello, Domenico; Schillaci, Orazio

    2014-12-09

    In the present short communication we considered the main publications focused on trigger prostate-specific antigen (PSA) and PSA kinetics that systematically compared 18F to 11C-choline PET/CT in order to establish the optimal time to perform choline PET/CT in relation to the trigger values and velocity, as well as doubling time of PSA serum levels.

  17. Development and application of probabilistic safety assessment PSA in Daya Bay Nuclear Power Station

    International Nuclear Information System (INIS)

    Huang Weigang; Chen Jiefei; Guo Jianbing; Zhen Wei

    2005-01-01

    This paper discusses the development and application of Level 1 PSA used for safety review, risk monitoring and on line maintenance of the nuclear power plant. PSA development includes the analysis of event tree, fault tree, FMEA, PSA quantification and the equipment reliability database. We have collected and processed the reliability data of external power source, the equipment reliability data and the initial event frequency. The thermal-hydraulics analysis of some important events and accidents, human factor analysis, and the calculation of human error probability have been made. During the development of event trees and fault trees, the effect of some support systems such as compressed air distribution system, ventilation system and electrical system have been taken into account. The system manuals, operation procedures and emergency operating procedures of Daya Bay NPP are referred to in this project. The operators of the NPP were involved in the establishment of all event trees and fault trees analysis. Furthermore, we have accepted the suggestion of IAEA experts, completed the logic chart of initial events to the initial events analysis of Daya Bay NPP, and optimized the code system of PSA model again. Together with the development of the reliability database, by absorbing the advanced experience of EDF, we have gained the reports about equipment's classifying, function and experience feedback information of Daya Bay NPP. According to the quantitative calculation of the latest Level 1 PSA Model of Daya Bay NPP, the results of Core Damage Frequency (CDF) is: CDF = 2.13E-5/reactor . year. The latest PSA Model of Daya Bay NPP includes: 1) 12 sorts of initial events, 67 sub-initial events, 70 fault trees; 2) 25 nuclear safety related systems were developed by fault trees and FMEA ; 3) 2609 fault tree logic gates; 4) 2146 basic events; 5) 680 core damage accident sequences. (authors)

  18. Review of APR+ Level 2 PSA

    International Nuclear Information System (INIS)

    Lehner, J.R.; Mubayi, V.; Pratt, W.T.

    2012-01-01

    Brookhaven National Laboratory (BNL) assisted the Korea Institute of Nuclear Safety (KINS) in reviewing the Level 2 Probabilistic Safety Assessment (PSA) of the APR+ Advanced Pressurized Water Reactor (PWR) prepared by the Korea Hydro and Nuclear Power Co., Ltd (KHNP) and KEPCO Engineering and Construction Co., Inc. (KEPCO-E and C). The work described in this report involves a review of the APR+ Level 2 PSA submittal (Ref. 1). The PSA and, therefore, the review is limited to consideration of accidents initiated by internal events. As part of the review process, the review team also developed three sets of Requests for Additional Information (RAIs). These RAIs were provided to KHNP and KEPCO-E and C for their evaluation and response. This final detailed report documents the review findings for each technical element of the PSA and includes consideration of all of the RAIs made by the reviewers as well as the associated responses. This final report was preceded by an interim report (Ref. 2) that focused on identifying important issues regarding the PSA. In addition, a final meeting on the project was held at BNL on November 21-22, 2011, where BNL and KINS reviewers discussed their preliminary review findings with KHNP and KEPCO-E and C staffs. Additional information obtained during this final meeting was also used to inform the review findings of this final report. The review focused not only on the robustness of the APR+ design to withstand severe accidents, but also on the capability and acceptability of the Level 2 PSA in terms of level of detail and completeness. The Korean nuclear regulatory authorities will decide whether the PSA is acceptable and the BNL review team is providing its comments for KINS consideration. Section 2.0 provides the basis for the BNL review. Section 3.0 presents the review of each technical element of the PSA. Conclusions and a summary are presented in Section 4.0. Section 5.0 contains the references.

  19. Case studies in Gaussian process modelling of computer codes

    International Nuclear Information System (INIS)

    Kennedy, Marc C.; Anderson, Clive W.; Conti, Stefano; O'Hagan, Anthony

    2006-01-01

    In this paper we present a number of recent applications in which an emulator of a computer code is created using a Gaussian process model. Tools are then applied to the emulator to perform sensitivity analysis and uncertainty analysis. Sensitivity analysis is used both as an aid to model improvement and as a guide to how much the output uncertainty might be reduced by learning about specific inputs. Uncertainty analysis allows us to reflect output uncertainty due to unknown input parameters, when the finished code is used for prediction. The computer codes themselves are currently being developed within the UK Centre for Terrestrial Carbon Dynamics

  20. Computer codes for beam dynamics analysis of cyclotronlike accelerators

    Science.gov (United States)

    Smirnov, V.

    2017-12-01

    Computer codes suitable for the study of beam dynamics in cyclotronlike (classical and isochronous cyclotrons, synchrocyclotrons, and fixed field alternating gradient) accelerators are reviewed. Computer modeling of cyclotron segments, such as the central zone, acceleration region, and extraction system is considered. The author does not claim to give a full and detailed description of the methods and algorithms used in the codes. Special attention is paid to the codes already proven and confirmed at the existing accelerating facilities. The description of the programs prepared in the worldwide known accelerator centers is provided. The basic features of the programs available to users and limitations of their applicability are described.

  1. LATTICE: an interactive lattice computer code

    International Nuclear Information System (INIS)

    Staples, J.

    1976-10-01

    LATTICE is a computer code which enables an interactive user to calculate the functions of a synchrotron lattice. This program satisfies the requirements at LBL for a simple interactive lattice program by borrowing ideas from both TRANSPORT and SYNCH. A fitting routine is included

  2. IAEA work with guides for PSA quality

    International Nuclear Information System (INIS)

    Hellstroem, Per

    2004-09-01

    IAEA has a project on development of a TECDOC 'PSA Quality for Various Applications'. The project develops the guidance document in stages with intermediate meetings with exchange of ideas, thoughts and experience. Draft versions are being produced successively. The objective with the project is to use attributes to describe the quality of different elements of a PSA (Analysis of initiating events, accident progression, system, data, human reliability, etc) making the PSA suitable for application in various risk informed activities. Two of the meetings in this project took place in February 2004 and in July 2004. The February meeting discussed different aspects of PSA quality in relation to applications and a draft of the TECDOC was reviewed. The meeting made recommendations for preparation of a final document and set priorities for further work in the area. The July meeting elaborated the document further in a small working group and a new draft version was prepared. A final version is expected to be published during 2005. The project has come to the conclusion that it is a limited number of PSA element attributes that are specific for a certain application. Most of the attributes concern plant specificity, realism and level of detail in a general manner, how plant specific is the model, how realistic and how detailed? Many attributes have the characteristic that they are good to have, but not necessarily needed to do the job. This last statement is valid both for a baseline PSA and a PSA application. The IAEA project has identified a limited number of attributes that are necessary to describe characteristics needed for specific applications. The PSA scope needed for a specific application is not covered by the project/document, even though it is obvious that different applications will need different scope or approaches to handle scope limitations. The guidance on performing a PSA available today is old. It is a need to review these guides and update with regard

  3. User's manual for computer code RIBD-II, a fission product inventory code

    International Nuclear Information System (INIS)

    Marr, D.R.

    1975-01-01

    The computer code RIBD-II is used to calculate inventories, activities, decay powers, and energy releases for the fission products generated in a fuel irradiation. Changes from the earlier RIBD code are: the expansion to include up to 850 fission product isotopes, input in the user-oriented NAMELIST format, and run-time choice of fuels from an extensively enlarged library of nuclear data. The library that is included in the code package contains yield data for 818 fission product isotopes for each of fourteen different fissionable isotopes, together with fission product transmutation cross sections for fast and thermal systems. Calculational algorithms are little changed from those in RIBD. (U.S.)

  4. CONPAS 1.0 (CONtainment Performance Analysis System). User`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Kwang Il; Jin, Young Ho [Korea Atomic Energy Research Institute, Daeduk (Korea, Republic of)

    1996-04-01

    CONPAS (CONtainment Performance Analysis System) is a verified computer code package to integrate the numerical, graphical, and results-operation aspects of Level 2 probabilistic safety assessments (PSA) for nuclear power plants automatically under a PC window environment. Compared with the existing DOS-based computer codes for Level 2 PSA, the most important merit of the window-based computer code is that user can easily describe and quantify the accident progression models, and manipulate the resultant outputs in a variety of ways. As a main logic for accident progression analysis, CONPAS employs a concept of the small containment phenomenological event tree (CPET) helpful to trace out visually individual accident progressions and of the large supporting event tree (LSET) for its detailed quantification. For the integrated analysis of Level 2 PSA, the code utilizes four distinct, but closely related modules; (1) ET Editor for construction of several event tree models describing the accident progressions, (2) Computer for quantification of the constructed event trees and graphical display of the resultant outputs, (3) Text Editor for preparation of input decks for quanification and utilization of calculational results, and (4) Mechanistic Code Plotter for utilization of results obtained from severe accident analysis codes. Compared with other existing computer codes for Level 2 PSA, the CONPAS code provides several advanced features: computational aspects including systematic uncertainty analysis, importance analysis, sensitivity analysis and data interpretation, reporting aspects including tabling and graphic as well as user-friend interface. 10 refs. (Author) .new.

  5. CONPAS 1.0 (CONtainment Performance Analysis System). User's manual

    International Nuclear Information System (INIS)

    Ahn, Kwang Il; Jin, Young Ho

    1996-04-01

    CONPAS (CONtainment Performance Analysis System) is a verified computer code package to integrate the numerical, graphical, and results-operation aspects of Level 2 probabilistic safety assessments (PSA) for nuclear power plants automatically under a PC window environment. Compared with the existing DOS-based computer codes for Level 2 PSA, the most important merit of the window-based computer code is that user can easily describe and quantify the accident progression models, and manipulate the resultant outputs in a variety of ways. As a main logic for accident progression analysis, CONPAS employs a concept of the small containment phenomenological event tree (CPET) helpful to trace out visually individual accident progressions and of the large supporting event tree (LSET) for its detailed quantification. For the integrated analysis of Level 2 PSA, the code utilizes four distinct, but closely related modules; (1) ET Editor for construction of several event tree models describing the accident progressions, (2) Computer for quantification of the constructed event trees and graphical display of the resultant outputs, (3) Text Editor for preparation of input decks for quanification and utilization of calculational results, and (4) Mechanistic Code Plotter for utilization of results obtained from severe accident analysis codes. Compared with other existing computer codes for Level 2 PSA, the CONPAS code provides several advanced features: computational aspects including systematic uncertainty analysis, importance analysis, sensitivity analysis and data interpretation, reporting aspects including tabling and graphic as well as user-friend interface. 10 refs. (Author) .new

  6. SWIMS: a small-angle multiple scattering computer code

    International Nuclear Information System (INIS)

    Sayer, R.O.

    1976-07-01

    SWIMS (Sigmund and WInterbon Multiple Scattering) is a computer code for calculation of the angular dispersion of ion beams that undergo small-angle, incoherent multiple scattering by gaseous or solid media. The code uses the tabulated angular distributions of Sigmund and Winterbon for a Thomas-Fermi screened Coulomb potential. The fraction of the incident beam scattered into a cone defined by the polar angle α is computed as a function of α for reduced thicknesses over the range 0.01 less than or equal to tau less than or equal to 10.0. 1 figure, 2 tables

  7. War of ontology worlds: mathematics, computer code, or Esperanto?

    Science.gov (United States)

    Rzhetsky, Andrey; Evans, James A

    2011-09-01

    The use of structured knowledge representations-ontologies and terminologies-has become standard in biomedicine. Definitions of ontologies vary widely, as do the values and philosophies that underlie them. In seeking to make these views explicit, we conducted and summarized interviews with a dozen leading ontologists. Their views clustered into three broad perspectives that we summarize as mathematics, computer code, and Esperanto. Ontology as mathematics puts the ultimate premium on rigor and logic, symmetry and consistency of representation across scientific subfields, and the inclusion of only established, non-contradictory knowledge. Ontology as computer code focuses on utility and cultivates diversity, fitting ontologies to their purpose. Like computer languages C++, Prolog, and HTML, the code perspective holds that diverse applications warrant custom designed ontologies. Ontology as Esperanto focuses on facilitating cross-disciplinary communication, knowledge cross-referencing, and computation across datasets from diverse communities. We show how these views align with classical divides in science and suggest how a synthesis of their concerns could strengthen the next generation of biomedical ontologies.

  8. Method comparison for determination of the tumor markers AFP, CEA, PSA and free PSA between Immulite 2000 XPI and Dimension Vista 1500.

    Science.gov (United States)

    Zur, Berndt; Holdenrieder, Stefan; Walgenbach-Brünagel, Gisela; Albers, Eike; Stoffel-Wagner, Birgit

    2012-01-01

    For the Luminescent Oxygen Channeling Immunoassay (LOCI) technology as established for Dimension Vista 1500, assays have been developed for the serum tumor markers AFP, CEA, PSA and free PSA. We performed a method analysis for these parameters using the Immulite 2000 XPI. Determination of within-day and total imprecision of the methods was carried out according to CLSI guidelines with three serum pools. In addition, parallel measurements were performed with both systems in 1,871 routine serum samples and correlations were calculated. Calculated total imprecision of the three serum pools for AFP was 3.8 - 4.3%, for CEA 3.3 - 4.3%, for tPSA 3.6 - 4.0% and for fPSA it was 3.5 - 8.2%. Correlations of these markers across the entire value range were very good with the following correlation coefficients: 0.997 for AFP, 0.996 for CEA, 0.971 for tPSA and 0.988 for fPSA. While values for AFP and tPSA from both methods were comparable (slopes 1.02 and 1.01), lower values were measured for CEA and fPSA with the Dimension Vista (slopes 0.83 and 0.91). For AFP, a sample cluster with considerably higher values than with Dimension Vista was observed in the lower measurement range (CEA, tPSA and fPSA, as developed with the LOCI technology for the Dimension Vista, show good comparability with results obtained from the Immulite 2000 XPI. However, lower measurement ranges for CEA and fPSA as well as individual divergences, especially with AFP, must be taken into consideration in the event of method changeover.

  9. Compendium of computer codes for the safety analysis of LMFBR's

    International Nuclear Information System (INIS)

    1975-06-01

    A high level of mathematical sophistication is required in the safety analysis of LMFBR's to adequately meet the demands for realism and confidence in all areas of accident consequence evaluation. The numerical solution procedures associated with these analyses are generally so complex and time consuming as to necessitate their programming into computer codes. These computer codes have become extremely powerful tools for safety analysis, combining unique advantages in accuracy, speed and cost. The number, diversity and complexity of LMFBR safety codes in the U. S. has grown rapidly in recent years. It is estimated that over 100 such codes exist in various stages of development throughout the country. It is inevitable that such a large assortment of codes will require rigorous cataloguing and abstracting to aid individuals in identifying what is available. It is the purpose of this compendium to provide such a service through the compilation of code summaries which describe and clarify the status of domestic LMFBR safety codes. (U.S.)

  10. Characteristics Studies of 125I- and total PSA antibody's Binding with prostate specific antigen (PSA) in Human Uterus Tumors

    International Nuclear Information System (INIS)

    Al-Mudaffar, S.; Al-Salihi, J.

    2005-01-01

    Two groups of uterus tumors (benign and malignant) postmenopausal patients were used to investigate the presence of prostate specific antigen (PSA). Preliminary experiments were performed to follow the binding of '1 25 I-anti total PSA antibody with PSA in uterus tissues homogenates of the two groups with their corresponding antigen and found to be (8.8,7.1%) for benign and malignant tumors, respectively. An Immuno Radio Metric Assay (IRMA) procedure was developed for measuring PSA in benign and malignant uterus tumors homogenates. The optimum conditions of the binding of 125 I-anti total PSA antibody with PSA were as follows: PSA concentration (150,200 μg protein),tracer antibody concentration (125,250 μg protein), p H (7.6,7.2), temp (15,25?C) and time (1.5 hrs) for postmenopausal benign and malignant uterus tumors tissue homogenates, respectively. The use of different concentrations of Na + and Mg 2+ ions were shown to cause an increase in the binding at concentration of (125,75 mΜ) of Na 1+ ions (75,225 mΜ) of Mg 2+ ions for benign and malignant uterus tumors homogenates, respectively, while the use of different concentrations of urea and polyethylene glycol (PEG) Caused a decrease in the binding with the increase in the concentration of each of urea and PEG in the both cases

  11. Fire propagation equation for the explicit identification of fire scenarios in a fire PSA

    International Nuclear Information System (INIS)

    Lim, Ho Gon; Han, Sang Hoon; Moon, Joo Hyun

    2011-01-01

    When performing fire PSA in a nuclear power plant, an event mapping method, using an internal event PSA model, is widely used to reduce the resources used by fire PSA model development. Feasible initiating events and component failure events due to fire are identified to transform the fault tree (FT) for an internal event PSA into one for a fire PSA using the event mapping method. A surrogate event or damage term method is used to condition the FT of the internal PSA. The surrogate event or the damage term plays the role of flagging whether the system/component in a fire compartment is damaged or not, depending on the fire being initiated from a specified compartment. These methods usually require explicit states of all compartments to be modeled in a fire area. Fire event scenarios, when using explicit identification, such as surrogate or damage terms, have two problems: there is no consideration of multiple fire propagation beyond a single propagation to an adjacent compartment, and there is no consideration of simultaneous fire propagations in which an initiating fire event is propagated to multiple paths simultaneously. The present paper suggests a fire propagation equation to identify all possible fire event scenarios for an explicitly treated fire event scenario in the fire PSA. Also, a method for separating fire events was developed to make all fire events a set of mutually exclusive events, which can facilitate arithmetic summation in fire risk quantification. A simple example is given to confirm the applicability of the present method for a 2x3 rectangular fire area. Also, a feasible asymptotic approach is discussed to reduce the computational burden for fire risk quantification

  12. User's manual for the NEFTRAN II computer code

    International Nuclear Information System (INIS)

    Olague, N.E.; Campbell, J.E.; Leigh, C.D.; Longsine, D.E.

    1991-02-01

    This document describes the NEFTRAN II (NEtwork Flow and TRANsport in Time-Dependent Velocity Fields) computer code and is intended to provide the reader with sufficient information to use the code. NEFTRAN II was developed as part of a performance assessment methodology for storage of high-level nuclear waste in unsaturated, welded tuff. NEFTRAN II is a successor to the NEFTRAN and NWFT/DVM computer codes and contains several new capabilities. These capabilities include: (1) the ability to input pore velocities directly to the transport model and bypass the network fluid flow model, (2) the ability to transport radionuclides in time-dependent velocity fields, (3) the ability to account for the effect of time-dependent saturation changes on the retardation factor, and (4) the ability to account for time-dependent flow rates through the source regime. In addition to these changes, the input to NEFTRAN II has been modified to be more convenient for the user. This document is divided into four main sections consisting of (1) a description of all the models contained in the code, (2) a description of the program and subprograms in the code, (3) a data input guide and (4) verification and sample problems. Although NEFTRAN II is the fourth generation code, this document is a complete description of the code and reference to past user's manuals should not be necessary. 19 refs., 33 figs., 25 tabs

  13. Guideline level-3 PSA

    International Nuclear Information System (INIS)

    Roelofsen, P.M.; Van der Steen, J.

    1993-09-01

    For several applications of radioactive materials calculations must be executed to determine the radiation risk for the population. A guideline for the risk calculation method of two main sources: nuclear power plants, and other intended and unintended activities with radioactive materials, is given. The standards, recommendations and regulations in this report concern mainly the analysis of the radiological (external) consequences of nuclear power plant accidents, classified as level-3 PSA (Probabilistic Safety Analysis). Level-3 PSA falls within the scales 5-7 of the International Nuclear Event Scale (INES). The standards, etc., focus on the risks for groups of people and the so-called maximum individual risk. In chapter two the standards and regulations are formulated for each part of level-3 PSA: the source term spectrum, atmospheric distribution and deposition, exposure to radiation doses and calculation of radiation doses, dose-response relationships, measures to reduce the effect of radiation doses, design basis accidents, and finally uncertainty analysis. In chapter four, modelled descriptions are given of the standards and regulations, which could or should be used in a calculation program in case of level-3 PSA. In chapter three the practical execution of a probabilistic consequences analysis, the collection of input data and the presentation of the results are dealt with. 2 figs., 14 tabs., 64 refs

  14. Gender codes why women are leaving computing

    CERN Document Server

    Misa, Thomas J

    2010-01-01

    The computing profession is facing a serious gender crisis. Women are abandoning the computing field at an alarming rate. Fewer are entering the profession than anytime in the past twenty-five years, while too many are leaving the field in mid-career. With a maximum of insight and a minimum of jargon, Gender Codes explains the complex social and cultural processes at work in gender and computing today. Edited by Thomas Misa and featuring a Foreword by Linda Shafer, Chair of the IEEE Computer Society Press, this insightful collection of essays explores the persisting gender imbalance in computing and presents a clear course of action for turning things around.

  15. Statistical screening of input variables in a complex computer code

    International Nuclear Information System (INIS)

    Krieger, T.J.

    1982-01-01

    A method is presented for ''statistical screening'' of input variables in a complex computer code. The object is to determine the ''effective'' or important input variables by estimating the relative magnitudes of their associated sensitivity coefficients. This is accomplished by performing a numerical experiment consisting of a relatively small number of computer runs with the code followed by a statistical analysis of the results. A formula for estimating the sensitivity coefficients is derived. Reference is made to an earlier work in which the method was applied to a complex reactor code with good results

  16. Improvement of level-1 PSA computer code package - Modeling and analysis for dynamic reliability of nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Hoon; Baek, Sang Yeup; Shin, In Sup; Moon, Shin Myung; Moon, Jae Phil; Koo, Hoon Young; Kim, Ju Shin [Seoul National University, Seoul (Korea, Republic of); Hong, Jung Sik [Seoul National Polytechnology University, Seoul (Korea, Republic of); Lim, Tae Jin [Soongsil University, Seoul (Korea, Republic of)

    1996-08-01

    The objective of this project is to develop a methodology of the dynamic reliability analysis for NPP. The first year`s research was focused on developing a procedure for analyzing failure data of running components and a simulator for estimating the reliability of series-parallel structures. The second year`s research was concentrated on estimating the lifetime distribution and PM effect of a component from its failure data in various cases, and the lifetime distribution of a system with a particular structure. Computer codes for performing these jobs were also developed. The objectives of the third year`s research is to develop models for analyzing special failure types (CCFs, Standby redundant structure) that were nor considered in the first two years, and to complete a methodology of the dynamic reliability analysis for nuclear power plants. The analysis of failure data of components and related researches for supporting the simulator must be preceded for providing proper input to the simulator. Thus this research is divided into three major parts. 1. Analysis of the time dependent life distribution and the PM effect. 2. Development of a simulator for system reliability analysis. 3. Related researches for supporting the simulator : accelerated simulation analytic approach using PH-type distribution, analysis for dynamic repair effects. 154 refs., 5 tabs., 87 figs. (author)

  17. A restructuring of CF package for MIDAS computer code

    International Nuclear Information System (INIS)

    Park, S. H.; Kim, K. R.; Kim, D. H.; Cho, S. W.

    2004-01-01

    CF package, which evaluates user-specified 'control functions' and applies them to define or control various aspects of computation, has been restructured for the MIDAS computer code. MIDAS is being developed as an integrated severe accident analysis code with a user-friendly graphical user interface and modernized data structure. To do this, data transferring methods of current MELCOR code are modified and adopted into the CF package. The data structure of the current MELCOR code using FORTRAN77 causes a difficult grasping of meaning of the variables as well as waste of memory, difficulty is more over because its data is location information of other package's data due to characteristics of CF package. New features of FORTRAN90 make it possible to allocate the storage dynamically and to use the user-defined data type, which lead to an efficient memory treatment and an easy understanding of the code. Restructuring of the CF package addressed in this paper includes module development, subroutine modification, and treats MELGEN, which generates data file, as well as MELCOR, which is processing a calculation. The verification has been done by comparing the results of the modified code with those from the existing code. As the trends are similar to each other, it hints that the same approach could be extended to the entire code package. It is expected that code restructuring will accelerate the code domestication thanks to direct understanding of each variable and easy implementation of modified or newly developed models

  18. A study on the nuclear computer codes installation and management system

    International Nuclear Information System (INIS)

    Kim, Yeon Seung; Huh, Young Hwan; Kim, Hee Kyung; Kang, Byung Heon; Kim, Ko Ryeo; Suh, Soong Hyok; Choi, Young Gil; Lee, Jong Bok

    1990-12-01

    From 1987 a number of technical transfer related to nuclear power plant had been performed from C-E for YGN 3 and 4 construction. Among them, installation and management of the computer codes for YGN 3 and 4 fuel and nuclear steam supply system was one of the most important project. Main objectives of this project are to establish the nuclear computer code management system, to develop QA procedure for nuclear codes, to secure the nuclear code reliability and to extend techanical applicabilities including the user-oriented utility programs for nuclear codes. Contents of performing the project in this year was to produce 215 transmittal packages of nuclear codes installation including making backup magnetic tape and microfiche for software quality assurance. Lastly, for easy reference about the nuclear codes information we presented list of code names and information on the codes which were introduced from C-E. (Author)

  19. Citham-2 computer code-User manual

    International Nuclear Information System (INIS)

    Batista, J.L.

    1984-01-01

    The procedures and the input data for the Citham-2 computer code are described. It is a subroutine that modifies the nuclide concentration taking in account its burn and prepares cross sections library in 2,3 or 4 energy groups, to the used for Citation program. (E.G.) [pt

  20. Citham a computer code for calculating fuel depletion-description, tests, modifications and evaluation

    International Nuclear Information System (INIS)

    Alvarenga, M.A.B.

    1984-12-01

    The CITHAN computer code was developed at IPEN (Instituto de Pesquisas Energeticas e Nucleares) to link the HAMMER computer code with a fuel depletion routine and to provide neutron cross sections to be read with the appropriate format of the CITATION code. The problem arised due to the efforts to addapt the new version denomined HAMMER-TECHION with the routine refered. The HAMMER-TECHION computer code was elaborated by Haifa Institute, Israel within a project with EPRI. This version is at CNEN to be used in multigroup constant generation for neutron diffusion calculation in the scope of the new methodology to be adopted by CNEN. The theoretical formulation of CITHAM computer code, tests and modificatins are described. (Author) [pt

  1. Computing Challenges in Coded Mask Imaging

    Science.gov (United States)

    Skinner, Gerald

    2009-01-01

    This slide presaentation reviews the complications and challenges in developing computer systems for Coded Mask Imaging telescopes. The coded mask technique is used when there is no other way to create the telescope, (i.e., when there are wide fields of view, high energies for focusing or low energies for the Compton/Tracker Techniques and very good angular resolution.) The coded mask telescope is described, and the mask is reviewed. The coded Masks for the INTErnational Gamma-Ray Astrophysics Laboratory (INTEGRAL) instruments are shown, and a chart showing the types of position sensitive detectors used for the coded mask telescopes is also reviewed. Slides describe the mechanism of recovering an image from the masked pattern. The correlation with the mask pattern is described. The Matrix approach is reviewed, and other approaches to image reconstruction are described. Included in the presentation is a review of the Energetic X-ray Imaging Survey Telescope (EXIST) / High Energy Telescope (HET), with information about the mission, the operation of the telescope, comparison of the EXIST/HET with the SWIFT/BAT and details of the design of the EXIST/HET.

  2. Computer code for quantitative ALARA evaluations

    International Nuclear Information System (INIS)

    Voilleque, P.G.

    1984-01-01

    A FORTRAN computer code has been developed to simplify the determination of whether dose reduction actions meet the as low as is reasonably achievable (ALARA) criterion. The calculations are based on the methodology developed for the Atomic Industrial Forum. The code is used for analyses of eight types of dose reduction actions, characterized as follows: reduce dose rate, reduce job frequency, reduce productive working time, reduce crew size, increase administrative dose limit for the task, and increase the workers' time utilization and dose utilization through (a) improved working conditions, (b) basic skill training, or (c) refresher training for special skills. For each type of action, two analysis modes are available. The first is a generic analysis in which the program computes potential benefits (in dollars) for a range of possible improvements, e.g., for a range of lower dose rates. Generic analyses are most useful in the planning stage and for evaluating the general feasibility of alternative approaches. The second is a specific analysis in which the potential annual benefits of a specific level of improvement and the annual implementation cost are compared. The potential benefits reflect savings in operational and societal costs that can be realized if occupational radiation doses are reduced. Because the potential benefits depend upon many variables which characterize the job, the workplace, and the workers, there is no unique relationship between the potential dollar savings and the dose savings. The computer code permits rapid quantitative analyses of alternatives and is a tool that supplements the health physicist's professional judgment. The program output provides a rational basis for decision-making and a record of the assumptions employed

  3. Computer-aided software understanding systems to enhance confidence of scientific codes

    International Nuclear Information System (INIS)

    Sheng, G.; Oeren, T.I.

    1991-01-01

    A unique characteristic of nuclear waste disposal is the very long time span over which the combined engineered and natural containment system must remain effective: hundreds of thousands of years. Since there is no precedent in human history for such an endeavour, simulation with the use of computers is the only means we have of forecasting possible future outcomes quantitatively. The need for reliable models and software to make such forecasts so far into the future is obvious. One of the critical elements necessary to ensure reliability is the degree of reviewability of the computer program. Among others, there are two very important reasons for this. Firstly, if there is to be any chance at all of validating the conceptual models as implemented by the computer code, peer reviewers must be able to see and understand what the program is doing. It is all but impossible to achieve this understanding by just looking at the code due to possible unfamiliarity with the language and often due as well to the length and complexity of the code. Secondly, a thorough understanding of the code is also necessary to carry out code maintenance activities which include among others, error detection, error correction and code modification for purposes of enhancing its performance, functionality or to adapt it to a changed environment. The emerging concepts of computer-aided software understanding and reverse engineering can answer precisely these needs. This paper will discuss the role they can play in enhancing the confidence one has on computer codes and several examples will be provided. Finally a brief discussion of combining state-of-art forward engineering systems with reverse engineering systems will show how powerfully they can contribute to the overall quality assurance of a computer program. (13 refs., 7 figs.)

  4. Algorithms and computer codes for atomic and molecular quantum scattering theory

    International Nuclear Information System (INIS)

    Thomas, L.

    1979-01-01

    This workshop has succeeded in bringing up 11 different coupled equation codes on the NRCC computer, testing them against a set of 24 different test problems and making them available to the user community. These codes span a wide variety of methodologies, and factors of up to 300 were observed in the spread of computer times on specific problems. A very effective method was devised for examining the performance of the individual codes in the different regions of the integration range. Many of the strengths and weaknesses of the codes have been identified. Based on these observations, a hybrid code has been developed which is significantly superior to any single code tested. Thus, not only have the original goals been fully met, the workshop has resulted directly in an advancement of the field. All of the computer programs except VIVS are available upon request from the NRCC. Since an improved version of VIVS is contained in the hybrid program, VIVAS, it was not made available for distribution. The individual program LOGD is, however, available. In addition, programs which compute the potential energy matrices of the test problems are also available. The software library names for Tests 1, 2 and 4 are HEH2, LICO, and EN2, respectively

  5. PSA-operations synergism for the advanced test reactor shutdown operations PSA

    International Nuclear Information System (INIS)

    Atkinson, S.A.

    1996-01-01

    The Advanced Test Reactor (ATR) Probabilistic Safety Assessment (PSA) for shutdown operations, cask handling, and canal draining is a successful example of the importance of good PSA-operations synergism for achieving a realistic and accepted assessment of the risks and for achieving desired risk reduction and safety improvement in a best and cost-effective manner. The implementation of the agreed-upon upgrades and improvements resulted in the reductions of the estimated mean frequency for core or canal irradiated fuel uncovery events, a total reduction in risk by a factor of nearly 1000 to a very low and acceptable risk level for potentially severe events

  6. GAM-HEAT -- a computer code to compute heat transfer in complex enclosures

    International Nuclear Information System (INIS)

    Cooper, R.E.; Taylor, J.R.; Kielpinski, A.L.; Steimke, J.L.

    1991-02-01

    The GAM-HEAT code was developed for heat transfer analyses associated with postulated Double Ended Guillotine Break Loss Of Coolant Accidents (DEGB LOCA) resulting in a drained reactor vessel. In these analyses the gamma radiation resulting from fission product decay constitutes the primary source of energy as a function of time. This energy is deposited into the various reactor components and is re- radiated as thermal energy. The code accounts for all radiant heat exchanges within and leaving the reactor enclosure. The SRS reactors constitute complex radiant exchange enclosures since there are many assemblies of various types within the primary enclosure and most of the assemblies themselves constitute enclosures. GAM-HEAT accounts for this complexity by processing externally generated view factors and connectivity matrices, and also accounts for convective, conductive, and advective heat exchanges. The code is applicable for many situations involving heat exchange between surfaces within a radiatively passive medium. The GAM-HEAT code has been exercised extensively for computing transient temperatures in SRS reactors with specific charges and control components. Results from these computations have been used to establish the need for and to evaluate hardware modifications designed to mitigate results of postulated accident scenarios, and to assist in the specification of safe reactor operating power limits. The code utilizes temperature dependence on material properties. The efficiency of the code has been enhanced by the use of an iterative equation solver. Verification of the code to date consists of comparisons with parallel efforts at Los Alamos National Laboratory and with similar efforts at Westinghouse Science and Technology Center in Pittsburgh, PA, and benchmarked using problems with known analytical or iterated solutions. All comparisons and tests yield results that indicate the GAM-HEAT code performs as intended

  7. Independent validation testing of the FLAME computer code, Version 1.0

    International Nuclear Information System (INIS)

    Martian, P.; Chung, J.N.

    1992-07-01

    Independent testing of the FLAME computer code, Version 1.0, was conducted to determine if the code is ready for use in hydrological and environmental studies at Department of Energy sites. This report describes the technical basis, approach, and results of this testing. Validation tests, (i.e., tests which compare field data to the computer generated solutions) were used to determine the operational status of the FLAME computer code and were done on a qualitative basis through graphical comparisons of the experimental and numerical data. These tests were specifically designed to check: (1) correctness of the FORTRAN coding, (2) computational accuracy, and (3) suitability to simulating actual hydrologic conditions. This testing was performed using a structured evaluation protocol which consisted of: (1) independent applications, and (2) graduated difficulty of test cases. Three tests ranging in complexity from simple one-dimensional steady-state flow field problems under near-saturated conditions to two-dimensional transient flow problems with very dry initial conditions

  8. Compilation of the abstracts of nuclear computer codes available at CPD/IPEN

    International Nuclear Information System (INIS)

    Granzotto, A.; Gouveia, A.S. de; Lourencao, E.M.

    1981-06-01

    A compilation of all computer codes available at IPEN in S.Paulo are presented. These computer codes are classified according to Argonne National Laboratory - and Energy Nuclear Agency schedule. (E.G.) [pt

  9. Validation of containment thermal hydraulic computer codes for VVER reactor

    Energy Technology Data Exchange (ETDEWEB)

    Jiri Macek; Lubomir Denk [Nuclear Research Institute Rez plc Thermal-Hydraulic Analyses Department CZ 250 68 Husinec-Rez (Czech Republic)

    2005-07-01

    Full text of publication follows: The Czech Republic operates 4 VVER-440 units, two VVER-1000 units are being finalized (one of them is undergoing commissioning). Thermal-hydraulics Department of the Nuclear Research Institute Rez performs accident analyses for these plants using a number of computer codes. To model the primary and secondary circuits behaviour the system codes ATHLET, CATHARE, RELAP, TRAC are applied. Containment and pressure-suppression system are modelled with COCOSYS and MELCOR codes, the reactor power calculations (point and space-neutron kinetics) are made with DYN3D, NESTLE and CDF codes (FLUENT, TRIO) are used for some specific problems.An integral part of the current Czech project 'New Energy Sources' is selection of a new nuclear source. Within this and the preceding projects financed by the Czech Ministry of Industry and Trade and the EU PHARE, the Department carries and has carried out the systematic validation of thermal-hydraulic and reactor physics computer codes applying data obtained on several experimental facilities as well as the real operational data. One of the important components of the VVER 440/213 NPP is its containment with pressure suppression system (bubble condenser). For safety analyses of this system, computer codes of the type MELCOR and COCOSYS are used in the Czech Republic. These codes were developed for containments of classic PWRs or BWRs. In order to apply these codes for VVER 440 systems, their validation on experimental facilities must be performed.The paper provides concise information on these activities of the NRI and its Thermal-hydraulics Department. The containment system of the VVER 440/213, its functions and approaches to solution of its safety is described with definition of acceptance criteria. A detailed example of the containment code validation on EREC Test facility (LOCA and MSLB) and the consequent utilisation of the results for a real NPP purposes is included. An approach to

  10. A Preliminary Fire PSA on PGSFR

    International Nuclear Information System (INIS)

    Kim, Kilyoo; Han, Sanghoon; Lee, KwiLim

    2017-01-01

    A Prototype Generation IV Sodium Fast Reactor (PGSFR) is under design with defense in depth concept with active, passive, and inherent safety features to acquire a design approval for PGSFR from Korean regulatory authority by around 2017. A preliminary fire PSA on PGSFR is done in 2016 and a final fire PSA of PGSFR will be done in 2017. The characteristics of the preliminary fire PSA on PGSFR are described in this paper. Since PGSFR is very safe reactor, it is not bad approach to use a conservative assumption in the preliminary PSA. In addition, several drawings including cable routing are not yet issued, a conservative calculation for CDF is performed. As shown in Table 2, the CDF caused by the fire in the control room takes 89% portion of total CDF. Thus, a detailed fire modeling for control room is necessary for the final fire PSA on PGSFR. Also, the increased ignition frequency due to sodium leak would be derived by considering the sodium piping complexity in the final fire PSA on PGSFR. The 4th column of Table 2 is derived the 3rd column by multiplying the factor (592/1177). The 5th column is the ignition frequency caused by the sodium leak. The 6th column is derived by summing the 4th column and the 5th column. The 7th column is the CDF portion of each fire area. The control room (fire area F-A404A) is the most important area since the control room fire takes 89% portion of total CDF.

  11. Regulatory requirements on PSA level 2: Review, aspects and applications

    International Nuclear Information System (INIS)

    Husarcek, J.

    2003-01-01

    The general requirements concerning utility obligations, probabilistic safety criteria (CDF should not exceed 1.0E-4/reactor year and LERF should not exceed 1.0E-5/reactor year), documentation and results, living PSA requirements and major steps in level 2 PSA are presented. PSA developments in Slovakia, collection and assembly of information, plant damage states, containment performance and failure modes, severe accident progression analyses, containment failure modes and source terms as a part of performed level 2 PSA are discussed. The PSA applications in design and operation evaluation, support to plant upgrade and modifications are also described. At the end, the following conclusion is made: more extensive PSA application needs to foster the exchange of experience and communication between PSA specialists, non-PSA engineers, designers, and the regulatory body staff responsible for safety assessment, inspection and enforcement

  12. The computer code EURDYN-1M (release 2). User's manual

    International Nuclear Information System (INIS)

    1982-01-01

    EURDYN-1M is a finite element computer code developed at J.R.C. Ispra to compute the response of two-dimensional coupled fluid-structure configurations to transient dynamic loading for reactor safety studies. This report gives instructions for preparing input data to EURDYN-1M, release 2, and describes a test problem in order to illustrate both the input and the output of the code

  13. Additional extensions to the NASCAP computer code, volume 3

    Science.gov (United States)

    Mandell, M. J.; Cooke, D. L.

    1981-01-01

    The ION computer code is designed to calculate charge exchange ion densities, electric potentials, plasma temperatures, and current densities external to a neutralized ion engine in R-Z geometry. The present version assumes the beam ion current and density to be known and specified, and the neutralizing electrons to originate from a hot-wire ring surrounding the beam orifice. The plasma is treated as being resistive, with an electron relaxation time comparable to the plasma frequency. Together with the thermal and electrical boundary conditions described below and other straightforward engine parameters, these assumptions suffice to determine the required quantities. The ION code, written in ASCII FORTRAN for UNIVAC 1100 series computers, is designed to be run interactively, although it can also be run in batch mode. The input is free-format, and the output is mainly graphical, using the machine-independent graphics developed for the NASCAP code. The executive routine calls the code's major subroutines in user-specified order, and the code allows great latitude for restart and parameter change.

  14. Verification study of the FORE-2M nuclear/thermal-hydraulilc analysis computer code

    International Nuclear Information System (INIS)

    Coffield, R.D.; Tang, Y.S.; Markley, R.A.

    1982-01-01

    The verification of the LMFBR core transient performance code, FORE-2M, was performed in two steps. Different components of the computation (individual models) were verified by comparing with analytical solutions and with results obtained from other conventionally accepted computer codes (e.g., TRUMP, LIFE, etc.). For verification of the integral computation method of the code, experimental data in TREAT, SEFOR and natural circulation experiments in EBR-II were compared with the code calculations. Good agreement was obtained for both of these steps. Confirmation of the code verification for undercooling transients is provided by comparisons with the recent FFTF natural circulation experiments. (orig.)

  15. An approach to develop a PSA workstation in KAERI

    International Nuclear Information System (INIS)

    Kim, T. W.; Han, S. H.; Park, C. K.

    1995-01-01

    This paper describes three kinds of efforts for the development of PSA workstation in KAERI; Development of a PSA tool, KIRAP, Reliability Database Development, Living PSA tool development. Korea has 9 nuclear power plants (NPPs) in operation and 9 NPPs under design or construction. For the NPPs recently constructed or designed, the probabilistic safety assessments (PSAs) have been performed by the Government requirements. For these PSAs, the MSDOS version of KIRAP has been used. For the consistent data management and the easiness of information handling needed in PSA, APSA workstation, KIRAP-Win is under development under Windows environment. For the reliability database on component failure rate, human error rate, and common cause failure rate, data used in international PSA or reliability data handbook are collected and processed to use in Korean new plants' PSAs. Finally, an effort for the development of a living PSA tool in KAERI based on dynamic PSA concept is described

  16. A methodology for PSA model validation

    International Nuclear Information System (INIS)

    Unwin, S.D.

    1995-09-01

    This document reports Phase 2 of work undertaken by Science Applications International Corporation (SAIC) in support of the Atomic Energy Control Board's Probabilistic Safety Assessment (PSA) review. A methodology is presented for the systematic review and evaluation of a PSA model. These methods are intended to support consideration of the following question: To within the scope and depth of modeling resolution of a PSA study, is the resultant model a complete and accurate representation of the subject plant? This question was identified as a key PSA validation issue in SAIC's Phase 1 project. The validation methods are based on a model transformation process devised to enhance the transparency of the modeling assumptions. Through conversion to a 'success-oriented' framework, a closer correspondence to plant design and operational specifications is achieved. This can both enhance the scrutability of the model by plant personnel, and provide an alternative perspective on the model that may assist in the identification of deficiencies. The model transformation process is defined and applied to fault trees documented in the Darlington Probabilistic Safety Evaluation. A tentative real-time process is outlined for implementation and documentation of a PSA review based on the proposed methods. (author). 11 refs., 9 tabs., 30 refs

  17. Development and perspectives of PSA in Cuba

    International Nuclear Information System (INIS)

    1996-01-01

    During the last decade the GDA/PSA has carried out the pre-operational PSA task for the Juragua Nuclear Power Plant. Since 1991 the work has been accomplished in the frames of the IAEA Technical Assistance Project CUB/9/008. The paper describes the stages of this study, (concluding with the Final Report of the pre-operational Level 1 PSA Rev. O), its assumptions, limitations and the main results and concluding remarks

  18. Computer code TOBUNRAD for PWR fuel bundle heat-up calculations

    International Nuclear Information System (INIS)

    Shimooke, Takanori; Yoshida, Kazuo

    1979-05-01

    The computer code TOBUNRAD developed is for analysis of ''fuel-bundle'' heat-up phenomena in a loss-of-coolant accident of PWR. The fuel bundle consists of fuel pins in square lattice; its behavior is different from that of individual pins during heat-up. The code is based on the existing TOODEE2 code which analyzes heat-up phenomena of single fuel pins, so that the basic models of heat conduction and transfer and coolant flow are the same as the TOODEE2's. In addition to the TOODEE2 features, unheated rods are modeled and radiation heat loss is considered between fuel pins, a fuel pin and other heat sinks. The TOBUNRAD code is developed by a new FORTRAN technique which makes it possible to interrupt a flow of program controls wherever desired, thereby attaching several subprograms to the main code. Users' manual for TOBUNRAD is presented: The basic program-structure by interruption method, physical and computational model in each sub-code, usage of the code and sample problems. (author)

  19. GASFLOW computer code (physical models and input data)

    International Nuclear Information System (INIS)

    Muehlbauer, Petr

    2007-11-01

    The GASFLOW computer code was developed jointly by the Los Alamos National Laboratory, USA, and Forschungszentrum Karlsruhe, Germany. The code is primarily intended for calculations of the transport, mixing, and combustion of hydrogen and other gases in nuclear reactor containments and in other facilities. The physical models and the input data are described, and a commented simple calculation is presented

  20. A zero-dimensional EXTRAP computer code

    International Nuclear Information System (INIS)

    Karlsson, P.

    1982-10-01

    A zero-dimensional computer code has been designed for the EXTRAP experiment to predict the density and the temperature and their dependence upon paramenters such as the plasma current and the filling pressure of neutral gas. EXTRAP is a Z-pinch immersed in a vacuum octupole field and could be either linear or toroidal. In this code the density and temperature are assumed to be constant from the axis up to a breaking point from where they decrease linearly in the radial direction out to the plasma radius. All quantities, however, are averaged over the plasma volume thus giving the zero-dimensional character of the code. The particle, momentum and energy one-fluid equations are solved including the effects of the surrounding neutral gas and oxygen impurities. The code shows that the temperature and density are very sensitive to the shape of the plasma, flatter profiles giving higher temperatures and densities. The temperature, however, is not strongly affected for oxygen concentration less than 2% and is well above the radiation barrier even for higher concentrations. (Author)

  1. The implementation of CP1 computer code in the Honeywell Bull computer in Brazilian Nuclear Energy Commission (CNEN)

    International Nuclear Information System (INIS)

    Couto, R.T.

    1987-01-01

    The implementation of the CP1 computer code in the Honeywell Bull computer in Brazilian Nuclear Energy Comission is presented. CP1 is a computer code used to solve the equations of punctual kinetic with Doppler feed back from the system temperature variation based on the Newton refrigeration equation (E.G.) [pt

  2. PSA applications

    International Nuclear Information System (INIS)

    Dubreuil Chambardel, A.

    1996-01-01

    The IAEA now defines three types of PSA applications: Validation of design and of operation procedures; optimization of plant operation; and regulatory applications. The applications of PSA are manifold: only a few are dealt with here (precursor analysis is dealt with in session 3, topic 4). For each of them, we will do the utmost to demonstrate the main difficulties encountered, EDF's viewpoint on the matter, and the points remaining to be solved. In what follows, unless explicitly stated otherwise, we have made every effort to represent the different applications as they are practiced by all concerned in the international community, and to describe the inherent difficulties the international community has encountered with these applications with all objectivity. It goes without saying that the comments below are simply those of the ESF department, and are submitted here for discussion by the experts. 13 refs

  3. PSA applications

    Energy Technology Data Exchange (ETDEWEB)

    Dubreuil Chambardel, A

    1997-12-31

    The IAEA now defines three types of PSA applications: Validation of design and of operation procedures; optimization of plant operation; and regulatory applications. The applications of PSA are manifold: only a few are dealt with here (precursor analysis is dealt with in session 3, topic 4). For each of them, we will do the utmost to demonstrate the main difficulties encountered, EDF`s viewpoint on the matter, and the points remaining to be solved. In what follows, unless explicitly stated otherwise, we have made every effort to represent the different applications as they are practiced by all concerned in the international community, and to describe the inherent difficulties the international community has encountered with these applications with all objectivity. It goes without saying that the comments below are simply those of the ESF department, and are submitted here for discussion by the experts. 13 refs.

  4. PSA testing anxiety, psychological morbidity, and PSA utility in the management of prostate cancer.

    OpenAIRE

    Micsunescu, Anamaria Elia

    2017-01-01

    Anecdotal reports from urologists and medical oncologists have suggested that patients with prostate cancer (PCa) often present with anxiety related to ongoing monitoring of their PSA levels as part of their disease management. The purpose of the current study, therefore, was to determine the prevalence and severity of prostate specific antigen (PSA) testing anxiety in a population of patients with either localised or metastatic PCa living in Australia. Other aspects of psychological morbidit...

  5. The computer code system for reactor radiation shielding in design of nuclear power plant

    International Nuclear Information System (INIS)

    Li Chunhuai; Fu Shouxin; Liu Guilian

    1995-01-01

    The computer code system used in reactor radiation shielding design of nuclear power plant includes the source term codes, discrete ordinate transport codes, Monte Carlo and Albedo Monte Carlo codes, kernel integration codes, optimization code, temperature field code, skyshine code, coupling calculation codes and some processing codes for data libraries. This computer code system has more satisfactory variety of codes and complete sets of data library. It is widely used in reactor radiation shielding design and safety analysis of nuclear power plant and other nuclear facilities

  6. Tools for PSA reviews

    International Nuclear Information System (INIS)

    Linden, J. von

    1998-01-01

    It is desirable to have a uniform and competent procedure for the review of PSAs which are performed within the framework of the Periodic Safety Review of German Nuclear Power Plants. Guidelines for the review process should therefore be evaluated within task A. 1 of project SR 2096. The basis for this work is the experience and knowledge within GRS derived from PSA-related work and from several review projects as well as the German PSA Guide with its appendices. Furthermore, the review processes in the USA, Switzerland and Sweden and the Guidelines for the International Peer Review Service (IPERS Guidelines) were utilized. As a result, recommendations are given for the review process, with individual recommendations concerning the organization of the review, task allocation between the reviewers, interface problems, assessment criteria, the scope and depth of the review as well as the supporting documents. An additional result are checklists for the technical elements of the PSA, which are listed to facilicate the review work. It is not the intention of this report to work out complete review guidelines. Its aims is rather more to give recommondations and support for the review in addition to what can be derived from the existing documents that should be used for the review. The recommendations reflect the view of GRS and go beyond the statements given in the German PSA Guide (Leitfaden Probabilistische Sicherheitsanalyse /PSUe97/) in some points. (orig.) [de

  7. Interface code between WIMS-AECL and RFSP-IST for coupling computing

    International Nuclear Information System (INIS)

    Xu Liangwang; Liu Yu; Jia Baoshan

    2007-01-01

    A code based on the protocols of Telnet and FTP is developed with C++ for coupling computing between WIMS-AECL and RFSP-IST. the input document of WIMS-AECL and RFSP-ISP cna be generated automatically and be submitted to server, the output document will be downloaded by the end of computing. the function of analyzing standard output document is also included in this code. After simple updating, this code can meet the requirement of other code using input document, e.g. CATHENA. A pilot study of the relation between void fraction and reactivity in TACR, some valuable conclusions has been achieved. (authors)

  8. DIAGNOSTIC AND PROGNOSTIC UTILITY OF SERUM PSA IN BREAST CANCER

    Institute of Scientific and Technical Information of China (English)

    张淑群; 强水云; 李妙羡; 纪宗正

    2004-01-01

    Objective To investigate the diagnostic and prognostic value of total and free prostate-specific antigen (PSA) in breast cancer women. Methods Using the microparticle enzyme immunoassay system, we measured the concentrations of these markers in the sera of 85 women with breast cancer and in 30 healthy women.Results Free PSA levels were significantly higher in women with breast cancer than healthy women (P <0. 05 ).The percentage of free PSA predominant subjects was 37. 6% in breast cancer patients and 3. 3% in healthy women.In women with breast cancer,total PSA positivity was 23.5% and free PSA positivity was 27. 1%. When compared to negatives,total PSA positive patients had a higher percentage of lymph node involvement tamours ( P >0. 05).However, patients with predominant free PSA had a higher percentage of early stage than patients with predominant PSA-ACT. Conclusion This study indicate clinical significance of preoperative measurement of serum total and free PSA in diagnosis and prognosis of women with breast cancer. The expression of KLKs is correlated with carcinogenesis of breast cancer.

  9. Repeat prostate-specific antigen (PSA) test before prostate biopsy: a 20% decrease in PSA values is associated with a reduced risk of cancer and particularly of high-grade cancer.

    Science.gov (United States)

    De Nunzio, Cosimo; Lombardo, Riccardo; Nacchia, Antonio; Tema, Giorgia; Tubaro, Andrea

    2018-07-01

    To analyse the impact of repeating a prostate-specific antigen (PSA) level assessment on prostate biopsy decision in a cohort of men undergoing prostate biopsy. From 2015 onwards, we consecutively enrolled, at a single institution in Italy, men undergoing 12-core transrectal ultrasonography-guided prostate needle biopsy. Indication for prostate biopsy was a PSA level of ≥4 ng/mL. Demographic, clinical, and histopathological data were collected. The PSA level was tested at enrolment (PSA 1 ) and 4 weeks later on the day before biopsy (PSA 2 ). Variations in PSA level were defined as: stable PSA 2 within a 10% variation, stable PSA 2 within a 20% variation, PSA 2 decreased by ≥10%, PSA 2 decreased by ≥20%, PSA 2 increased by ≥10%, PSA 2 increased by ≥20%, and PSA 2 PSA within 20% variation had a higher risk of prostate cancer (odds ratio [OR] 1.80, P PSA2 decreased by ≥20% had a lower risk of prostate cancer (OR 0.37, P PSA2 increased by ≥10% had an increased risk of high-grade prostate cancer (OR 1.93, P PSA returned to normal values (PSA levels significantly reduced the risk of high-grade prostate cancer. Further multicentre studies should validate our present results. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.

  10. TPASS: a gamma-ray spectrum analysis and isotope identification computer code

    International Nuclear Information System (INIS)

    Dickens, J.K.

    1981-03-01

    The gamma-ray spectral data-reduction and analysis computer code TPASS is described. This computer code is used to analyze complex Ge(Li) gamma-ray spectra to obtain peak areas corrected for detector efficiencies, from which are determined gamma-ray yields. These yields are compared with an isotope gamma-ray data file to determine the contributions to the observed spectrum from decay of specific radionuclides. A complete FORTRAN listing of the code and a complex test case are given

  11. A framework for a quality assurance programme for PSA

    International Nuclear Information System (INIS)

    1999-08-01

    Reviews organized by the IAEA of probabilistic safety assessments (PSAs) of nuclear facilities have, in the past years, shown significant progress in the technical methods and data used for these studies. The IAEA has made a considerable effort to support the development of technical capabilities for PSA in Member States and in writing technical procedures for carrying out PSAs. However, the reviews have also shown significant deficiencies in quality assurance (QA) for PSAs, ranging from no QA at all to inappropriate, inefficient or unbalanced QA. As a PSA represents a very complex model which describes the risk associated with a nuclear facility, an appropriate and efficient QA programme is crucial to obtain a quality PSA. Historically, in the first integral PSAs, many of the PSA elements were handled by independent groups. These elements were finally integrated and put together in the overall model. Many of the interfaces between the elements or tasks were handled as appropriate by exchanging information in oral or written form. Since WASH-1400, the first integral PSA, the process of constructing the PSA model has been further developed. PSA elements previously considered separately can now be handled together with the capable software developed in recent years. Software has made interface control and data transfer easier to perform, but also permits the development of more detailed and complex models. Previously, QA for PSA projects was organized in an ad hoc manner and was sometimes very limited. In recent years, increasingly comprehensive QA programmes have been developed and implemented for PSA projects. Today, a comprehensive, effective and performance-oriented QA is considered to be essential for a reliable and credible PSA. This report describes the framework for developing an adequate QA programme for PSA studies. The framework is based on and is in accordance with the related QA guidelines of the IAEA for safety in nuclear power plants and other nuclear

  12. Final guidance document for extended Level 2 PSA Volume 1. Summary report for external hazards implementation in extended L2 PSA, validation of SAMG strategy and complement of ASAMPSA2 L2PSA guidance

    International Nuclear Information System (INIS)

    Loeffler, H.; Raimond, E.

    2016-01-01

    The present document is a summary of the deliverables produced within the ASAMPSA-E project for extended L2 PSA. These deliverables are: D30.7 vol. 2, 'Implementing external Events modelling in Level 2 PSA': D30.7 vol. 3: 'Verification and improvement of SAM strategy: D30.7 vol. 4: 'Consideration of shutdown states, spent fuel pools and recent R and D results'. Among many others, the following summary statements are provided: Analyses of external events: - No need for new methodology, - It is necessary to develop L1 PSA first and then clearly defined boundary conditions for the L2 PSA must be generated, - The remaining challenge is how to address adverse environmental conditions due to external hazards. Multi units: - No practical methodology exists to treat the problem, - A new methodology is necessary to be developed first for the L1 PSA. This should, from the beginning, take into account the specific needs of L2 PSA so that the boundary conditions for subsequent level 2 analysis can be generated adequately. SAM strategies verification and improvement: - L2 PSA methodology can usefully by applied and experience exists for internal initiating events L2 PSA, - How to address adverse environmental conditions due to external hazards - needs for new methodology or examples of experience, - How to model the decision process when there is a conflict of interest - needs for new methodology or examples of experience. For L2 PSA in shutdown states with open RPV, some new technical issues (fission product release, thermal load to structures above RPV) have to be addressed. Spent fuel pool issues have been developed, in particular: - Heat load from the melting spent fuel to structures above (e.g. to the containment roof) is a severe challenge for the plant and for the present-day, methodology is missing. Recent R and D achievements with relevance for L2 PSA: - Basic research has been continued in the radiochemistry (iodine and ruthenium chemistry) field, but the existing

  13. Development of the computer code system for the analyses of PWR core

    International Nuclear Information System (INIS)

    Tsujimoto, Iwao; Naito, Yoshitaka.

    1992-11-01

    This report is one of the materials for the work titled 'Development of the computer code system for the analyses of PWR core phenomena', which is performed under contracts between Shikoku Electric Power Company and JAERI. In this report, the numerical method adopted in our computer code system are described, that is, 'The basic course and the summary of the analysing method', 'Numerical method for solving the Boltzmann equation', 'Numerical method for solving the thermo-hydraulic equations' and 'Description on the computer code system'. (author)

  14. Code system to compute radiation dose in human phantoms

    International Nuclear Information System (INIS)

    Ryman, J.C.; Cristy, M.; Eckerman, K.F.; Davis, J.L.; Tang, J.S.; Kerr, G.D.

    1986-01-01

    Monte Carlo photon transport code and a code using Monte Carlo integration of a point kernel have been revised to incorporate human phantom models for an adult female, juveniles of various ages, and a pregnant female at the end of the first trimester of pregnancy, in addition to the adult male used earlier. An analysis code has been developed for deriving recommended values of specific absorbed fractions of photon energy. The computer code system and calculational method are described, emphasizing recent improvements in methods

  15. Computer codes developed in FRG to analyse hypothetical meltdown accidents

    International Nuclear Information System (INIS)

    Hassmann, K.; Hosemann, J.P.; Koerber, H.; Reineke, H.

    1978-01-01

    It is the purpose of this paper to give the status of all significant computer codes developed in the core melt-down project which is incorporated in the light water reactor safety research program of the Federal Ministry of Research and Technology. For standard pressurized water reactors, results of some computer codes will be presented, describing the course and the duration of the hypothetical core meltdown accident. (author)

  16. H0 precessor computer code

    International Nuclear Information System (INIS)

    van Dyck, O.B.; Floyd, R.A.

    1981-05-01

    A spin precessor using H - to H 0 stripping, followed by small precession magnets, has been developed for the LAMPF 800-MeV polarized H - beam. The performance of the system was studied with the computer code documented in this report. The report starts from the fundamental physics of a system of spins with hyperfine coupling in a magnetic field and contains many examples of beam behavior as calculated by the program

  17. PSA Model Improvement Using Maintenance Rule Function Mapping

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Mi Ro [KHNP-CRI, Nuclear Safety Laboratory, Daejeon (Korea, Republic of)

    2011-10-15

    The Maintenance Rule (MR) program, in nature, is a performance-based program. Therefore, the risk information derived from the Probabilistic Safety Assessment model is introduced into the MR program during the Safety Significance determination and Performance Criteria selection processes. However, this process also facilitates the determination of the vulnerabilities in currently utilized PSA models and offers means of improving them. To find vulnerabilities in an existing PSA model, an initial review determines whether the safety-related MR functions are included in the PSA model. Because safety-related MR functions are related to accident prevention and mitigation, it is generally necessary for them to be included in the PSA model. In the process of determining the safety significance of each functions, quantitative risk importance levels are determined through a process known as PSA model basic event mapping to MR functions. During this process, it is common for some inadequate and overlooked models to be uncovered. In this paper, the PSA model and the MR program of Wolsong Unit 1 were used as references

  18. Predictor of response to salvage radiotherapy in patients with PSA recurrence after radical prostatectomy. The usefulness of PSA doubling time

    International Nuclear Information System (INIS)

    Numata, Kousaku; Azuma, Koji; Hashine, Katsuyoshi; Sumiyoshi, Yoshiteru

    2005-01-01

    We assessed predictors of response to salvage radiotherapy (sRT) in patients with prostate-specific antigen (PSA) recurrence after radical prostatectomy. A total of 21 patients receiving sRT for PSA recurrence without systemic progression after radical prostatectomy had medical records available for retrospective review. We defined sRT as external beam radiotherapy for patients with a continuous increase in PSA level≥0.2 ng/ml after radical prostatectomy. Response was defined as achievement of a PSA nadir of ≤0.1 ng/ml. Various pre-treatment parameters were evaluated retrospectively. The median follow-up period after sRT was 38 months. Of the 21 patients, 15 were good responders (71%). The only predictive factor was PSA doubling time (PSADT). Age and PSA level at diagnosis, Gleason score and surgical margin status were not significant predictors of response. The median PSADT in responders was 6.2 months versus 1.9 months in non-responders (P=0.019). The patients with a PSADT of ≥5 months were all responders. PSADT appears to be a good predictor of response to sRT. sRT was especially effective when PSADT was ≥5 months. (author)

  19. A three-dimensional magnetostatics computer code for insertion devices

    International Nuclear Information System (INIS)

    Chubar, O.; Elleaume, P.; Chavanne, J.

    1998-01-01

    RADIA is a three-dimensional magnetostatics computer code optimized for the design of undulators and wigglers. It solves boundary magnetostatics problems with magnetized and current-carrying volumes using the boundary integral approach. The magnetized volumes can be arbitrary polyhedrons with non-linear (iron) or linear anisotropic (permanent magnet) characteristics. The current-carrying elements can be straight or curved blocks with rectangular cross sections. Boundary conditions are simulated by the technique of mirroring. Analytical formulae used for the computation of the field produced by a magnetized volume of a polyhedron shape are detailed. The RADIA code is written in object-oriented C++ and interfaced to Mathematica (Mathematica is a registered trademark of Wolfram Research, Inc.). The code outperforms currently available finite-element packages with respect to the CPU time of the solver and accuracy of the field integral estimations. An application of the code to the case of a wedge-pole undulator is presented

  20. PSA in operator training

    International Nuclear Information System (INIS)

    Nos, V.; Faig, J.; Plesa, P.; Delgado, J. L.

    2000-01-01

    The systematic approach to training is internationally accepted as the best method to achieve and maintain the qualification and competence of power plant personnel and to guarantee the quality of their training. Following the recommendations and guidelines of international organisations competent in the field, TECNATOM SA has developed projects based on the systematic approach to training for all Spanish nuclear power plants. One of the latest projects was the systematic approach to training developed for the operation personnel of ASCO Nuclear Power Plant. In this case, certain results of the Probabilistic Safety Analysis (PSA) which complement the systematic safety and reliability criteria of the systematic approach to training process have been incorporated in the traditional processes of work and task analysis and training plan design. This incorporation provides the training manager with additional criteria based not only on safety aspects obtained through the statistical treatment of considerations of skilled technical personnel (operators, operation chief supervisors, etc), but also on the independent criterion of the PSA. The inclusion of this approach basically affects all systematics in two of its stages: During the selection process of operating practices in SMR or SGI, the possible scenarios have been associated with all those situations where human actions which lead to an initiating event or human actions to mitigate an initiating event, may take place, as defined in the PSA. During the scenario development process, the instruments involved in the performance of human actions which originate or mitigate an event taking place have been identified. This pakes it possible to reconcile the scenario event sequence with the sequence considered in the PSA study, as the most likely to provoke a more serious accident. The incorporation of these PSA results contributes to the strengthening of safety aspects in training in an objective way, and confirms that

  1. Computation of the Genetic Code

    Science.gov (United States)

    Kozlov, Nicolay N.; Kozlova, Olga N.

    2018-03-01

    One of the problems in the development of mathematical theory of the genetic code (summary is presented in [1], the detailed -to [2]) is the problem of the calculation of the genetic code. Similar problems in the world is unknown and could be delivered only in the 21st century. One approach to solving this problem is devoted to this work. For the first time provides a detailed description of the method of calculation of the genetic code, the idea of which was first published earlier [3]), and the choice of one of the most important sets for the calculation was based on an article [4]. Such a set of amino acid corresponds to a complete set of representations of the plurality of overlapping triple gene belonging to the same DNA strand. A separate issue was the initial point, triggering an iterative search process all codes submitted by the initial data. Mathematical analysis has shown that the said set contains some ambiguities, which have been founded because of our proposed compressed representation of the set. As a result, the developed method of calculation was limited to the two main stages of research, where the first stage only the of the area were used in the calculations. The proposed approach will significantly reduce the amount of computations at each step in this complex discrete structure.

  2. Upgrade of internal events PSA model using the AESJ level-1 PSA standard for operating state

    International Nuclear Information System (INIS)

    Sato, Teruyoshi; Yoneyama, Mitsuru; Hirokawa, Naoki; Sato, Chikahiro; Sato, Eisuke; Tomizawa, Shigeatsu

    2009-01-01

    In 2003, the Atomic Energy Society of Japan (AESJ) started to develop the Level-1 Probabilistic Safety Assessment (PSA) standard of internal events for operating state (AESJ standard). The AESJ standard has been finished to be asked for public comment. Using the AESJ standard (draft version), the authors have upgraded the PSA model for Tokyo Electric Power Company (TEPCO) BWR-5 plant not only to reflect latest knowledge but also to ensure high quality of PSA model (not yet peer-reviewed) for the purpose of better operation and maintenance management of TEPCO BWR plants. For example, the categorization of structures, systems and components (SSCs) will be performed to improve nuclear reactor safety using information of risk importance. (author)

  3. PORPST: A statistical postprocessor for the PORMC computer code

    International Nuclear Information System (INIS)

    Eslinger, P.W.; Didier, B.T.

    1991-06-01

    This report describes the theory underlying the PORPST code and gives details for using the code. The PORPST code is designed to do statistical postprocessing on files written by the PORMC computer code. The data written by PORMC are summarized in terms of means, variances, standard deviations, or statistical distributions. In addition, the PORPST code provides for plotting of the results, either internal to the code or through use of the CONTOUR3 postprocessor. Section 2.0 discusses the mathematical basis of the code, and Section 3.0 discusses the code structure. Section 4.0 describes the free-format point command language. Section 5.0 describes in detail the commands to run the program. Section 6.0 provides an example program run, and Section 7.0 provides the references. 11 refs., 1 fig., 17 tabs

  4. BWROPT: A multi-cycle BWR fuel cycle optimization code

    Energy Technology Data Exchange (ETDEWEB)

    Ottinger, Keith E.; Maldonado, G. Ivan, E-mail: Ivan.Maldonado@utk.edu

    2015-09-15

    Highlights: • A multi-cycle BWR fuel cycle optimization algorithm is presented. • New fuel inventory and core loading pattern determination. • The parallel simulated annealing algorithm was used for the optimization. • Variable sampling probabilities were compared to constant sampling probabilities. - Abstract: A new computer code for performing BWR in-core and out-of-core fuel cycle optimization for multiple cycles simultaneously has been developed. Parallel simulated annealing (PSA) is used to optimize the new fuel inventory and placement of new and reload fuel for each cycle considered. Several algorithm improvements were implemented and evaluated. The most significant of these are variable sampling probabilities and sampling new fuel types from an ordered array. A heuristic control rod pattern (CRP) search algorithm was also implemented, which is useful for single CRP determinations, however, this feature requires significant computational resources and is currently not practical for use in a full multi-cycle optimization. The PSA algorithm was demonstrated to be capable of significant objective function reduction and finding candidate loading patterns without constraint violations. The use of variable sampling probabilities was shown to reduce runtime while producing better results compared to using constant sampling probabilities. Sampling new fuel types from an ordered array was shown to have a mixed effect compared to random new fuel type sampling, whereby using both random and ordered sampling produced better results but required longer runtimes.

  5. Main Aspects and Results of Level 2 PSA for KNPP WWER-1000/B320

    International Nuclear Information System (INIS)

    Mancheva, Kaliopa

    2014-01-01

    The PSA Level 2 for Kozloduy NPP (KNPP) is an update of an older study with wider scope of analysis. The older study represented the status of the units up to 2001. The current PSA Level 2 is based on the PSA Level 1 and represents the status of the units up to 2007 year concerning the systems and procedures included in PSA level 1 and status up to 2011 for the systems and procedures (e.g. SAMG) related to containment and severe accident aspects. The study is performed after the PSA level 1 has been finished and approved by the customer. Compare to the older analysis all modes of operation for analyzed in PSA level 1 event groups as well Spent Fuel Pool accidents are investigated. The analysis consists of both deterministic and probabilistic analysis. As part of deterministic analysis a contemporary containment strength analysis and accident progression deterministic analysis using last version of MELCOR are performed. The probabilistic analysis contains of two part: Interface PSA and CET are calculated using Riskspectrum program code. Two types of models for CET have been developed: one for conditional probabilities calculations and a set of simplified CET's for each PDS group-for integral model. The purpose of the first model is to be able to perform quick calculations and for sensitivity analyses as well. The simplified CET's are used for integral calculation of the model. Source Term analysis is mainly based on the MELCOR analyses results. All characteristics of the releases have been defined, i.e. location, mass, energy of radionuclide groups and activity of the released isotopes (most important are reported only). The main goals of the study are to analyze the status of the containment, systems designed to prevent containment failure and operator action required under the severe accident and to give quantitative assessment of the risk parameter LERF (Large Early Release Frequency). This report will present main aspects, results, finding and

  6. Microdosimetry computation code of internal sources - MICRODOSE 1

    International Nuclear Information System (INIS)

    Li Weibo; Zheng Wenzhong; Ye Changqing

    1995-01-01

    This paper describes a microdosimetry computation code, MICRODOSE 1, on the basis of the following described methods: (1) the method of calculating f 1 (z) for charged particle in the unit density tissues; (2) the method of calculating f(z) for a point source; (3) the method of applying the Fourier transform theory to the calculation of the compound Poisson process; (4) the method of using fast Fourier transform technique to determine f(z) and, giving some computed examples based on the code, MICRODOSE 1, including alpha particles emitted from 239 Pu in the alveolar lung tissues and from radon progeny RaA and RAC in the human respiratory tract. (author). 13 refs., 6 figs

  7. Probabilistic evaluations for CANTUP computer code analysis improvement

    International Nuclear Information System (INIS)

    Florea, S.; Pavelescu, M.

    2004-01-01

    Structural analysis with finite element method is today an usual way to evaluate and predict the behavior of structural assemblies subject to hard conditions in order to ensure their safety and reliability during their operation. A CANDU 600 fuel channel is an example of an assembly working in hard conditions, in which, except the corrosive and thermal aggression, long time irradiation, with implicit consequences on material properties evolution, interferes. That leads inevitably to material time-dependent properties scattering, their dynamic evolution being subject to a great degree of uncertainness. These are the reasons for developing, in association with deterministic evaluations with computer codes, the probabilistic and statistical methods in order to predict the structural component response. This work initiates the possibility to extend the deterministic thermomechanical evaluation on fuel channel components to probabilistic structural mechanics approach starting with deterministic analysis performed with CANTUP computer code which is a code developed to predict the long term mechanical behavior of the pressure tube - calandria tube assembly. To this purpose the structure of deterministic calculus CANTUP computer code has been reviewed. The code has been adapted from LAHEY 77 platform to Microsoft Developer Studio - Fortran Power Station platform. In order to perform probabilistic evaluations, it was added a part to the deterministic code which, using a subroutine from IMSL library from Microsoft Developer Studio - Fortran Power Station platform, generates pseudo-random values of a specified value. It was simulated a normal distribution around the deterministic value and 5% standard deviation for Young modulus material property in order to verify the statistical calculus of the creep behavior. The tube deflection and effective stresses were the properties subject to probabilistic evaluation. All the values of these properties obtained for all the values for

  8. Results of level 1 PSA in Trillo 1 NPP

    International Nuclear Information System (INIS)

    Gomez, F.; Lopez, C.

    1998-01-01

    In July 1991, C. N. Trillo I was requested by the Spanish Regulatory Body (CSN) to perform a PSA that should include: - Level 1 PSA at power - Internal flooding analysis - Level 2 PSA including containment capacity analysis. - External event analyses (fires, external flooding, seismic events and other external events) - Risk analysis for off power conditions (shutdown and low power) - Risk analysis due to other sources of radioactivity In 1992 the Project Plan was issued and the PSA team for the performance of Level 1 PSA was established. Before finishing the Project, it was decided to develop a Phase B to take into account some important modifications that had been accomplished in the Plant and that, probably, could affect the results. Level 1 PSA was finished in March 1998. Both the results of the study and the main conclusions derived from the importance, uncertainty and sensibility analysis performed are presented in this paper. These results de not include the internal flooding analysis conclusions and correspond to PSA revision 0 that is currently being evaluated by the Spanish Regulatory Body. (Author)

  9. Parameters that affect parallel processing for computational electromagnetic simulation codes on high performance computing clusters

    Science.gov (United States)

    Moon, Hongsik

    What is the impact of multicore and associated advanced technologies on computational software for science? Most researchers and students have multicore laptops or desktops for their research and they need computing power to run computational software packages. Computing power was initially derived from Central Processing Unit (CPU) clock speed. That changed when increases in clock speed became constrained by power requirements. Chip manufacturers turned to multicore CPU architectures and associated technological advancements to create the CPUs for the future. Most software applications benefited by the increased computing power the same way that increases in clock speed helped applications run faster. However, for Computational ElectroMagnetics (CEM) software developers, this change was not an obvious benefit - it appeared to be a detriment. Developers were challenged to find a way to correctly utilize the advancements in hardware so that their codes could benefit. The solution was parallelization and this dissertation details the investigation to address these challenges. Prior to multicore CPUs, advanced computer technologies were compared with the performance using benchmark software and the metric was FLoting-point Operations Per Seconds (FLOPS) which indicates system performance for scientific applications that make heavy use of floating-point calculations. Is FLOPS an effective metric for parallelized CEM simulation tools on new multicore system? Parallel CEM software needs to be benchmarked not only by FLOPS but also by the performance of other parameters related to type and utilization of the hardware, such as CPU, Random Access Memory (RAM), hard disk, network, etc. The codes need to be optimized for more than just FLOPs and new parameters must be included in benchmarking. In this dissertation, the parallel CEM software named High Order Basis Based Integral Equation Solver (HOBBIES) is introduced. This code was developed to address the needs of the

  10. Perspectives of Living PSA in NPP Krsko

    International Nuclear Information System (INIS)

    Vrbanic, I.; Kastelan, M.

    1996-01-01

    Nuclear power plant Krsko has completed the Level 1/Level 2 Probabilistic Safety Analysis (PSA) for internal initiating events and is in the process of completing the same for the external initiators. The analysis completed up to now has provided a valuable insight into a plant risk profile. In NPP Krsko there is a plan to use the PSA model as a permanent tool for the risk based applications and incorporate it into a decision making process. In order to achieve this there is a need to permanently maintain the PSA model in a manner that it reflects both the plan configuration/design at a time point and the operational experience up to the time point. All the activities aimed toward keeping the PSA model up-to-dated in this sense are usually referred to as a Living PSA (LPSA) program. NPP Krsko is in the process of defining and proceduralizing a LPSA program that would be plant specific and based on known world practices. Further, in order to be suitable for risk based applications the PSA model must be flexible in a sense that modifications to the base case model may be done easily and requantifications performed quickly as to evaluate various conditions imposed by real or hypothetical situations. NPP Krsko PSA model has been based on licensing type software. The requirements specified above dictate the transfer of the overall model to an application oriented software of newer generation with larger capabilities. The transfer becomes a part of a mentioned ongoing effort aimed at establishing LPSA model and concept. The paper present this effort and the perspectives of LPSA concept and risk based applications in NPP Krsko. (author)

  11. Validation of thermohydraulic codes by comparison of experimental results with computer simulations

    International Nuclear Information System (INIS)

    Madeira, A.A.; Galetti, M.R.S.; Pontedeiro, A.C.

    1989-01-01

    The results obtained by simulation of three cases from CANON depressurization experience, using the TRAC-PF1 computer code, version 7.6, implanted in the VAX-11/750 computer of Brazilian CNEN, are presented. The CANON experience was chosen as first standard problem in thermo-hydraulic to be discussed at ENFIR for comparing results from different computer codes with results obtained experimentally. The ability of TRAC-PF1 code to prevent the depressurization phase of a loss of primary collant accident in pressurized water reactors is evaluated. (M.C.K.) [pt

  12. Core melt progression and consequence analysis methodology development in support of the Savannah River Reactor PSA

    International Nuclear Information System (INIS)

    O'Kula, K.R.; Sharp, D.A.; Amos, C.N.; Wagner, K.C.; Bradley, D.R.

    1992-01-01

    A three-level Probabilistic Safety Assessment (PSA) of production reactor operation has been underway since 1985 at the US Department of Energy's Savannah River Site (SRS). The goals of this analysis are to: Analyze existing margins of safety provided by the heavy-water reactor (HWR) design challenged by postulated severe accidents; Compare measures of risk to the general public and onsite workers to guideline values, as well as to those posed by commercial reactor operation; and Develop the methodology and database necessary to prioritize improvements to engineering safety systems and components, operator training, and engineering projects that contribute significantly to improving plant safety. PSA technical staff from the Westinghouse Savannah River Company (WSRC) and Science Applications International Corporation (SAIC) have performed the assessment despite two obstacles: A variable baseline plant configuration and power level; and a lack of technically applicable code methodology to model the SRS reactor conditions. This paper discusses the detailed effort necessary to modify the requisite codes before accident analysis insights for the risk assessment were obtained

  13. CASKETSS: a computer code system for thermal and structural analysis of nuclear fuel shipping casks

    International Nuclear Information System (INIS)

    Ikushima, Takeshi

    1989-02-01

    A computer program CASKETSS has been developed for the purpose of thermal and structural analysis of nuclear fuel shipping casks. CASKETSS measn a modular code system for CASK Evaluation code system Thermal and Structural Safety. Main features of CASKETSS are as follow; (1) Thermal and structural analysis computer programs for one-, two-, three-dimensional geometries are contained in the code system. (2) Some of the computer programs in the code system has been programmed to provide near optimal speed on vector processing computers. (3) Data libralies fro thermal and structural analysis are provided in the code system. (4) Input data generator is provided in the code system. (5) Graphic computer program is provided in the code system. In the paper, brief illustration of calculation method, input data and sample calculations are presented. (author)

  14. Multitasking the code ARC3D. [for computational fluid dynamics

    Science.gov (United States)

    Barton, John T.; Hsiung, Christopher C.

    1986-01-01

    The CRAY multitasking system was developed in order to utilize all four processors and sharply reduce the wall clock run time. This paper describes the techniques used to modify the computational fluid dynamics code ARC3D for this run and analyzes the achieved speedup. The ARC3D code solves either the Euler or thin-layer N-S equations using an implicit approximate factorization scheme. Results indicate that multitask processing can be used to achieve wall clock speedup factors of over three times, depending on the nature of the program code being used. Multitasking appears to be particularly advantageous for large-memory problems running on multiple CPU computers.

  15. A new 3-D integral code for computation of accelerator magnets

    International Nuclear Information System (INIS)

    Turner, L.R.; Kettunen, L.

    1991-01-01

    For computing accelerator magnets, integral codes have several advantages over finite element codes; far-field boundaries are treated automatically, and computed field in the bore region satisfy Maxwell's equations exactly. A new integral code employing edge elements rather than nodal elements has overcome the difficulties associated with earlier integral codes. By the use of field integrals (potential differences) as solution variables, the number of unknowns is reduced to one less than the number of nodes. Two examples, a hollow iron sphere and the dipole magnet of Advanced Photon Source injector synchrotron, show the capability of the code. The CPU time requirements are comparable to those of three-dimensional (3-D) finite-element codes. Experiments show that in practice it can realize much of the potential CPU time saving that parallel processing makes possible. 8 refs., 4 figs., 1 tab

  16. Regulatory review of probabilistic safety assessment (PSA) Level 2

    International Nuclear Information System (INIS)

    2001-07-01

    Probabilistic safety assessment (PSA) is increasingly being used as part of the decision making process to assess the level of safety of nuclear power plants. The methodologies in use are maturing and the insights gained from the PSAs are being used along with those from deterministic analysis. Many regulatory authorities consider the current state of the art in PSA to be sufficiently well developed for results to be used centrally in the regulatory decision making process-referred to as risk informed regulation. For these applications to be successful, it will be necessary for the regulatory authority to have a high degree of confidence in the PSA. However, at the 1994 IAEA Technical Committee Meeting on Use of PSA in the Regulatory Process and at the OECD Nuclear Energy Agency Committee for Nuclear Regulatory Activities (CNRA) 'Special Issues' meeting in 1997 on Review Procedures and Criteria for Different Regulatory Applications of PSA, it was recognized that formal regulatory review guidance for PSA did not exist. The senior regulators noted that there was a need to produce some international guidance for reviewing PSAs to establish an agreed basis for assessing whether important technological and methodological issues in PSAs are treated adequately and to verify that conclusions reached are appropriate. In 1997, the IAEA and OECD Nuclear Energy Agency agreed to produce, in cooperation, guidance on Regulatory Review of PSA. This led to the publication of IAEA-TECDOC-1135 on the Regulatory Review of Probabilistic Safety Assessment (PSA) Level 1, which gives advice for the review of Level 1 PSA for initiating events occurring at power plants. This TECDOC extends the coverage to address the regulatory review of Level 2 PSA.These publications are intended to provide guidance to regulatory authorities on how to review the PSA for a nuclear power plant to gain confidence that it has been carried out to an acceptable level of quality so that it can be used as the

  17. Analysis of parallel computing performance of the code MCNP

    International Nuclear Information System (INIS)

    Wang Lei; Wang Kan; Yu Ganglin

    2006-01-01

    Parallel computing can reduce the running time of the code MCNP effectively. With the MPI message transmitting software, MCNP5 can achieve its parallel computing on PC cluster with Windows operating system. Parallel computing performance of MCNP is influenced by factors such as the type, the complexity level and the parameter configuration of the computing problem. This paper analyzes the parallel computing performance of MCNP regarding with these factors and gives measures to improve the MCNP parallel computing performance. (authors)

  18. Regulatory review of probabilistic safety assessment (PSA) level 1

    International Nuclear Information System (INIS)

    2000-02-01

    Probabilistic safety assessment (PSA) is increasingly being used as part of the decision making process to assess the level of safety of nuclear power plants. The methodologies in use are maturing and the insights gained from the PSAs are being used along with those from the deterministic analysis. Many regulatory authorities consider that the current state of the art in PSA (especially Level 1 PSA) is sufficiently well developed that it can be used centrally in the regulatory decision making process - referred to as 'risk informed regulation'. For these applications to be successful, it will be necessary for regulatory authorities to have a high degree of confidence in PSA. However, at the IAEA Technical Committee Meeting on Use of PSA in the Regulatory Process in 1994 and at the OECD Nuclear Energy Agency Committee for Nuclear Regulatory Activities (CNRA) 'Special Issues' Meeting in 1997 on Review Procedures and Criteria for Different Regulatory Applications of PSA, it was recognized that formal regulatory review guidance for PSA did not exist. The senior regulators noted that there was a need to produce some international guidance for reviewing PSAs to establish an agreed basis for assessing whether important technological and methodological issues in PSAs are treated adequately and to verify that conclusions reached are appropriate. In 1997 the IAEA and OECD Nuclear Energy Agency agreed to produce in co-operation a technical document on the regulatory review of PSA. This publication is intended to provide guidance to regulatory authorities on how to review the PSA for a nuclear power plant to gain confidence that it has been carried out to an acceptable standard so that it can be used as the basis for taking risk informed decisions within a regulatory decision making process. The document gives guidance on how to set about reviewing a PSA and on the technical issues that need to be addressed. This publication gives guidance for the review of Level 1 PSA for

  19. Clinical performance of serum prostate-specific antigen isoform [-2]proPSA (p2PSA) and its derivatives, %p2PSA and the prostate health index (PHI), in men with a family history of prostate cancer: results from a multicentre European study, the PROMEtheuS project.

    Science.gov (United States)

    Lazzeri, Massimo; Haese, Alexander; Abrate, Alberto; de la Taille, Alexandre; Redorta, Joan Palou; McNicholas, Thomas; Lughezzani, Giovanni; Lista, Giuliana; Larcher, Alessandro; Bini, Vittorio; Cestari, Andrea; Buffi, Nicolòmaria; Graefen, Markus; Bosset, Olivier; Le Corvoisier, Philippe; Breda, Alberto; de la Torre, Pablo; Fowler, Linda; Roux, Jacques; Guazzoni, Giorgio

    2013-08-01

    To test the sensitivity, specificity and accuracy of serum prostate-specific antigen isoform [-2]proPSA (p2PSA), %p2PSA and the prostate health index (PHI), in men with a family history of prostate cancer (PCa) undergoing prostate biopsy for suspected PCa. To evaluate the potential reduction in unnecessary biopsies and the characteristics of potentially missed cases of PCa that would result from using serum p2PSA, %p2PSA and PHI. The analysis consisted of a nested case-control study from the PRO-PSA Multicentric European Study, the PROMEtheuS project. All patients had a first-degree relative (father, brother, son) with PCa. Multivariable logistic regression models were complemented by predictive accuracy analysis and decision-curve analysis. Of the 1026 patients included in the PROMEtheuS cohort, 158 (15.4%) had a first-degree relative with PCa. p2PSA, %p2PSA and PHI values were significantly higher (P PHI (AUC: 0.733) to be the most accurate predictors of PCa at biopsy, significantly outperforming total PSA ([tPSA] AUC: 0.549), free PSA ([fPSA] AUC: 0.489) and %fPSA (AUC: 0.600) (P ≤ 0.001). For %p2PSA a threshold of 1.66 was found to have the best balance between sensitivity and specificity (70.4 and 70.1%; 95% confidence interval [CI]: 58.4-80.7 and 59.4-79.5 respectively). A PHI threshold of 40 was found to have the best balance between sensitivity and specificity (64.8 and 71.3%, respectively; 95% CI 52.5-75.8 and 60.6-80.5). At 90% sensitivity, the thresholds for %p2PSA and PHI were 1.20 and 25.5, with a specificity of 37.9 and 25.5%, respectively. At a %p2PSA threshold of 1.20, a total of 39 (24.8%) biopsies could have been avoided, but two cancers with a Gleason score (GS) of 7 would have been missed. At a PHI threshold of 25.5 a total of 27 (17.2%) biopsies could have been avoided and two (3.8%) cancers with a GS of 7 would have been missed. In multivariable logistic regression models, %p2PSA and PHI achieved independent predictor status and

  20. Applications of probabilistic safety assessment (PSA) for nuclear power plants

    International Nuclear Information System (INIS)

    2001-02-01

    This report, which compiles information on a comprehensive set of PSA applications in the areas of NPP design, operation, and accident mitigation and management, is the culmination of an IAEA project on PSA Applications and Tools to Improve NPP Safety. In this regard, the Technical Committee Meeting (TCM) held in Madrid in February 1998 allowed participants to review and provide very valuable comments for this report. Several important facts related to PSA and its applications were highlighted during this TCM: living PSAs are the basis for the risk informed approach to decision making; development and use of safety/risk monitors as tools for configuration management is spreading fast; the different uses of PSA to support NPP testing and maintenance planning and optimization are amongst the most widespread PSA applications; plant specific PSAs are being used to support the safety upgrading programmes of plants built to earlier standards; not all countries have a regulatory framework for the use of the probabilistic approach in decision making. Some countries are still far from 'risk-informed' regulation, and this means that there is still considerable work ahead, both for regulators and utilities, to clarify approaches, to establish a framework and to reach a common understanding in relation to the use of PSA in decision making. This report is based on the premise that the use of PSA can provide useful information for the decision maker. This report is intended to provide an overview of current PSA applications. Section 2 addresses the PSA application process, outlines the general requirements for PSA tools and provides a discussion on PSA aspects such as PSA level, scope and level of detail, which have to be considered when planning/performing PSA applications. Section 3 discusses the technical aspects of individual applications and is divided into three parts. Section 3.1 is dedicated to the design related PSA applications. The second part of Section 3 considers

  1. Linking CATHENA with other computer codes through a remote process

    Energy Technology Data Exchange (ETDEWEB)

    Vasic, A.; Hanna, B.N.; Waddington, G.M. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada); Sabourin, G. [Atomic Energy of Canada Limited, Montreal, Quebec (Canada); Girard, R. [Hydro-Quebec, Montreal, Quebec (Canada)

    2005-07-01

    'Full text:' CATHENA (Canadian Algorithm for THErmalhydraulic Network Analysis) is a computer code developed by Atomic Energy of Canada Limited (AECL). The code uses a transient, one-dimensional, two-fluid representation of two-phase flow in piping networks. CATHENA is used primarily for the analysis of postulated upset conditions in CANDU reactors; however, the code has found a wider range of applications. In the past, the CATHENA thermalhydraulics code included other specialized codes, i.e. ELOCA and the Point LEPreau CONtrol system (LEPCON) as callable subroutine libraries. The combined program was compiled and linked as a separately named code. This code organizational process is not suitable for independent development, maintenance, validation and version tracking of separate computer codes. The alternative solution to provide code development independence is to link CATHENA to other computer codes through a Parallel Virtual Machine (PVM) interface process. PVM is a public domain software package, developed by Oak Ridge National Laboratory and enables a heterogeneous collection of computers connected by a network to be used as a single large parallel machine. The PVM approach has been well accepted by the global computing community and has been used successfully for solving large-scale problems in science, industry, and business. Once development of the appropriate interface for linking independent codes through PVM is completed, future versions of component codes can be developed, distributed separately and coupled as needed by the user. This paper describes the coupling of CATHENA to the ELOCA-IST and the TROLG2 codes through a PVM remote process as an illustration of possible code connections. ELOCA (Element Loss Of Cooling Analysis) is the Industry Standard Toolset (IST) code developed by AECL to simulate the thermo-mechanical response of CANDU fuel elements to transient thermalhydraulics boundary conditions. A separate ELOCA driver program

  2. Linking CATHENA with other computer codes through a remote process

    International Nuclear Information System (INIS)

    Vasic, A.; Hanna, B.N.; Waddington, G.M.; Sabourin, G.; Girard, R.

    2005-01-01

    'Full text:' CATHENA (Canadian Algorithm for THErmalhydraulic Network Analysis) is a computer code developed by Atomic Energy of Canada Limited (AECL). The code uses a transient, one-dimensional, two-fluid representation of two-phase flow in piping networks. CATHENA is used primarily for the analysis of postulated upset conditions in CANDU reactors; however, the code has found a wider range of applications. In the past, the CATHENA thermalhydraulics code included other specialized codes, i.e. ELOCA and the Point LEPreau CONtrol system (LEPCON) as callable subroutine libraries. The combined program was compiled and linked as a separately named code. This code organizational process is not suitable for independent development, maintenance, validation and version tracking of separate computer codes. The alternative solution to provide code development independence is to link CATHENA to other computer codes through a Parallel Virtual Machine (PVM) interface process. PVM is a public domain software package, developed by Oak Ridge National Laboratory and enables a heterogeneous collection of computers connected by a network to be used as a single large parallel machine. The PVM approach has been well accepted by the global computing community and has been used successfully for solving large-scale problems in science, industry, and business. Once development of the appropriate interface for linking independent codes through PVM is completed, future versions of component codes can be developed, distributed separately and coupled as needed by the user. This paper describes the coupling of CATHENA to the ELOCA-IST and the TROLG2 codes through a PVM remote process as an illustration of possible code connections. ELOCA (Element Loss Of Cooling Analysis) is the Industry Standard Toolset (IST) code developed by AECL to simulate the thermo-mechanical response of CANDU fuel elements to transient thermalhydraulics boundary conditions. A separate ELOCA driver program starts, ends

  3. Computer codes for evaluation of control room habitability (HABIT)

    International Nuclear Information System (INIS)

    Stage, S.A.

    1996-06-01

    This report describes the Computer Codes for Evaluation of Control Room Habitability (HABIT). HABIT is a package of computer codes designed to be used for the evaluation of control room habitability in the event of an accidental release of toxic chemicals or radioactive materials. Given information about the design of a nuclear power plant, a scenario for the release of toxic chemicals or radionuclides, and information about the air flows and protection systems of the control room, HABIT can be used to estimate the chemical exposure or radiological dose to control room personnel. HABIT is an integrated package of several programs that previously needed to be run separately and required considerable user intervention. This report discusses the theoretical basis and physical assumptions made by each of the modules in HABIT and gives detailed information about the data entry windows. Sample runs are given for each of the modules. A brief section of programming notes is included. A set of computer disks will accompany this report if the report is ordered from the Energy Science and Technology Software Center. The disks contain the files needed to run HABIT on a personal computer running DOS. Source codes for the various HABIT routines are on the disks. Also included are input and output files for three demonstration runs

  4. High-performance computational fluid dynamics: a custom-code approach

    International Nuclear Information System (INIS)

    Fannon, James; Náraigh, Lennon Ó; Loiseau, Jean-Christophe; Valluri, Prashant; Bethune, Iain

    2016-01-01

    We introduce a modified and simplified version of the pre-existing fully parallelized three-dimensional Navier–Stokes flow solver known as TPLS. We demonstrate how the simplified version can be used as a pedagogical tool for the study of computational fluid dynamics (CFDs) and parallel computing. TPLS is at its heart a two-phase flow solver, and uses calls to a range of external libraries to accelerate its performance. However, in the present context we narrow the focus of the study to basic hydrodynamics and parallel computing techniques, and the code is therefore simplified and modified to simulate pressure-driven single-phase flow in a channel, using only relatively simple Fortran 90 code with MPI parallelization, but no calls to any other external libraries. The modified code is analysed in order to both validate its accuracy and investigate its scalability up to 1000 CPU cores. Simulations are performed for several benchmark cases in pressure-driven channel flow, including a turbulent simulation, wherein the turbulence is incorporated via the large-eddy simulation technique. The work may be of use to advanced undergraduate and graduate students as an introductory study in CFDs, while also providing insight for those interested in more general aspects of high-performance computing. (paper)

  5. High-performance computational fluid dynamics: a custom-code approach

    Science.gov (United States)

    Fannon, James; Loiseau, Jean-Christophe; Valluri, Prashant; Bethune, Iain; Náraigh, Lennon Ó.

    2016-07-01

    We introduce a modified and simplified version of the pre-existing fully parallelized three-dimensional Navier-Stokes flow solver known as TPLS. We demonstrate how the simplified version can be used as a pedagogical tool for the study of computational fluid dynamics (CFDs) and parallel computing. TPLS is at its heart a two-phase flow solver, and uses calls to a range of external libraries to accelerate its performance. However, in the present context we narrow the focus of the study to basic hydrodynamics and parallel computing techniques, and the code is therefore simplified and modified to simulate pressure-driven single-phase flow in a channel, using only relatively simple Fortran 90 code with MPI parallelization, but no calls to any other external libraries. The modified code is analysed in order to both validate its accuracy and investigate its scalability up to 1000 CPU cores. Simulations are performed for several benchmark cases in pressure-driven channel flow, including a turbulent simulation, wherein the turbulence is incorporated via the large-eddy simulation technique. The work may be of use to advanced undergraduate and graduate students as an introductory study in CFDs, while also providing insight for those interested in more general aspects of high-performance computing.

  6. New coding technique for computer generated holograms.

    Science.gov (United States)

    Haskell, R. E.; Culver, B. C.

    1972-01-01

    A coding technique is developed for recording computer generated holograms on a computer controlled CRT in which each resolution cell contains two beam spots of equal size and equal intensity. This provides a binary hologram in which only the position of the two dots is varied from cell to cell. The amplitude associated with each resolution cell is controlled by selectively diffracting unwanted light into a higher diffraction order. The recording of the holograms is fast and simple.

  7. Clinical outcomes and nadir prostate-specific antigen (PSA) according to initial PSA levels in primary androgen deprivation therapy for metastatic prostate cancer.

    Science.gov (United States)

    Kitagawa, Yasuhide; Ueno, Satoru; Izumi, Kouji; Kadono, Yoshifumi; Mizokami, Atsushi; Hinotsu, Shiro; Akaza, Hideyuki; Namiki, Mikio

    2016-03-01

    To investigate the clinical outcomes of metastatic prostate cancer patients and the relationship between nadir prostate-specific antigen (PSA) levels and different types of primary androgen deprivation therapy (PADT). This study utilized data from the Japan Study Group of Prostate Cancer registry, which is a large, multicenter, population-based database. A total of 2982 patients treated with PADT were enrolled. Kaplan-Meier analysis was used to compare progression-free survival (PFS) and overall survival (OS) in patients treated using combined androgen blockade (CAB) and non-CAB therapies. The relationships between nadir PSA levels and PADT type according to initial serum PSA levels were also investigated. Among the 2982 enrolled patients, 2101 (70.5 %) were treated with CAB. Although CAB-treated patients had worse clinical characteristics, their probability of PFS and OS was higher compared with those treated with a non-CAB therapy. These results were due to a survival benefit with CAB in patients with an initial PSA level of 500-1000 ng/mL. Nadir PSA levels were significantly lower in CAB patients than in non-CAB patients with comparable initial serum PSA levels. A small survival benefit for CAB in metastatic prostate cancer was demonstrated in a Japanese large-scale prospective cohort study. The clinical significance of nadir PSA levels following PADT was evident, but the predictive impact of PSA nadir on OS was different between CAB and non-CAB therapy.

  8. PSA in design of passive/active safety reactors

    International Nuclear Information System (INIS)

    Sato, T.; Tanabe, A.; Kondo, S.

    1995-01-01

    PSAs in the design of advanced reactors are applied mainly in level 1 PSA areas. However, even in level 1 PSA, there are certain areas where special care must be taken depending on plant design concepts. This paper identifies these areas both for passive and active safety reactor concepts. For example, 'long-term PSA' and shutdown PSA are very important for a passive safety reactor concept from the standpoint of effectiveness of a grace period and passive safety systems. External events are also important for an active safety reactor concept. These kinds of special PSAs are difficult to conduct precisely in a conceptual design stage. This paper shows methods of conducting these kinds of special PSAs simply and conveniently and the use of acquired insights for the design of advanced reactors. This paper also clarifies the meaning or definition of a grace period from the standpoint of PSA

  9. Hauser*5, a computer code to calculate nuclear cross sections

    International Nuclear Information System (INIS)

    Mann, F.M.

    1979-07-01

    HAUSER*5 is a computer code that uses the statistical (Hauser-Feshbach) model, the pre-equilibrium model, and a statistical model of direct reactions to predict nuclear cross sections. The code is unrestricted as to particle type, includes fission and capture, makes width-fluctuation corrections, and performs three-body calculations - all in minimum computer time. Transmission coefficients can be generated internally or supplied externally. This report describes equations used, necessary input, and resulting output. 2 figures, 4 tables

  10. NADAC and MERGE: computer codes for processing neutron activation analysis data

    International Nuclear Information System (INIS)

    Heft, R.E.; Martin, W.E.

    1977-01-01

    Absolute disintegration rates of specific radioactive products induced by neutron irradition of a sample are determined by spectrometric analysis of gamma-ray emissions. Nuclide identification and quantification is carried out by a complex computer code GAMANAL (described elsewhere). The output of GAMANAL is processed by NADAC, a computer code that converts the data on observed distintegration rates to data on the elemental composition of the original sample. Computations by NADAC are on an absolute basis in that stored nuclear parameters are used rather than the difference between the observed disintegration rate and the rate obtained by concurrent irradiation of elemental standards. The NADAC code provides for the computation of complex cases including those involving interrupted irradiations, parent and daughter decay situations where the daughter may also be produced independently, nuclides with very short half-lives compared to counting interval, and those involving interference by competing neutron-induced reactions. The NADAC output consists of a printed report, which summarizes analytical results, and a card-image file, which can be used as input to another computer code MERGE. The purpose of MERGE is to combine the results of multiple analyses and produce a single final answer, based on all available information, for each element found

  11. PSA data base, comparison of the German and French approach

    International Nuclear Information System (INIS)

    Kreuser, A.; Tirira, J.

    2001-01-01

    The results of probabilistic safety assessments (PSA) of nuclear power plants strongly depend on the reliability data used. This report describes coarsely the general process to generate reliability data for components and resumes the differences between the German and French approaches. As has been shown in former studies which compared international PSA data, PSA data are closely related to the model definitions of the PSA. Therefore single PSA data cannot be compared directly without regard e.g. to the corresponding fault trees. These findings are confirmed by this study. The comparison of German and French methods shows a lot of differences concerning various details of the data generation process. Some differences between single reliability data should be eliminated when taking into account the complete fault tree analysis. But there are some other differences which have a direct impact on the obtained results of a PSA. In view of the all differences between both approaches concerning the definition of data and the data collection process, it is not possible to compare directly German and French PSA data. However, the database differences give no indication on the influence on the PSA results. Therefore, it is a need to perform a common IPSN/GRS assessment on how the different databases impact the PSA results. (orig.)

  12. Survey of computer codes applicable to waste facility performance evaluations

    International Nuclear Information System (INIS)

    Alsharif, M.; Pung, D.L.; Rivera, A.L.; Dole, L.R.

    1988-01-01

    This study is an effort to review existing information that is useful to develop an integrated model for predicting the performance of a radioactive waste facility. A summary description of 162 computer codes is given. The identified computer programs address the performance of waste packages, waste transport and equilibrium geochemistry, hydrological processes in unsaturated and saturated zones, and general waste facility performance assessment. Some programs also deal with thermal analysis, structural analysis, and special purposes. A number of these computer programs are being used by the US Department of Energy, the US Nuclear Regulatory Commission, and their contractors to analyze various aspects of waste package performance. Fifty-five of these codes were identified as being potentially useful on the analysis of low-level radioactive waste facilities located above the water table. The code summaries include authors, identification data, model types, and pertinent references. 14 refs., 5 tabs

  13. A preliminary investigation of PSA validation methods

    Energy Technology Data Exchange (ETDEWEB)

    Unwin, S D [Science Applications International Corp., (United States)

    1995-09-01

    This document has been prepared to support the initial phase of the Atomic Energy Control Board`s program to review and evaluate Probabilistic Safety Assessment (PSA) studies conducted by nuclear generating station designers and licensees. The document provides (1) a review of current and prospective applications of PSA technology in the Canadian nuclear power industry; (2) an assessment of existing practices and techniques for the review or risk and hazard identification studies in the international nuclear power sector and other technological sectors; and (3) proposed analytical framework in which to develop systematic techniques for the scrutiny and evaluation of a PSA model. These frameworks are based on consideration of the mathematical structure of a PSA model and are intended to facilitate the development of methods to evaluate a model relative to intended end-uses. (author). 34 refs., 10 tabs., 3 figs.

  14. A preliminary investigation of PSA validation methods

    International Nuclear Information System (INIS)

    Unwin, S.D.

    1995-09-01

    This document has been prepared to support the initial phase of the Atomic Energy Control Board's program to review and evaluate Probabilistic Safety Assessment (PSA) studies conducted by nuclear generating station designers and licensees. The document provides (1) a review of current and prospective applications of PSA technology in the Canadian nuclear power industry; (2) an assessment of existing practices and techniques for the review or risk and hazard identification studies in the international nuclear power sector and other technological sectors; and (3) proposed analytical framework in which to develop systematic techniques for the scrutiny and evaluation of a PSA model. These frameworks are based on consideration of the mathematical structure of a PSA model and are intended to facilitate the development of methods to evaluate a model relative to intended end-uses. (author). 34 refs., 10 tabs., 3 figs

  15. Poisson/Superfish codes for personal computers

    International Nuclear Information System (INIS)

    Humphries, S.

    1992-01-01

    The Poisson/Superfish codes calculate static E or B fields in two-dimensions and electromagnetic fields in resonant structures. New versions for 386/486 PCs and Macintosh computers have capabilities that exceed the mainframe versions. Notable improvements are interactive graphical post-processors, improved field calculation routines, and a new program for charged particle orbit tracking. (author). 4 refs., 1 tab., figs

  16. CAT: a computer code for the automated construction of fault trees

    International Nuclear Information System (INIS)

    Apostolakis, G.E.; Salem, S.L.; Wu, J.S.

    1978-03-01

    A computer code, CAT (Computer Automated Tree, is presented which applies decision table methods to model the behavior of components for systematic construction of fault trees. The decision tables for some commonly encountered mechanical and electrical components are developed; two nuclear subsystems, a Containment Spray Recirculation System and a Consequence Limiting Control System, are analyzed to demonstrate the applications of CAT code

  17. The role of PSA in safety management

    International Nuclear Information System (INIS)

    Szikszai, T.

    1997-01-01

    The presentation discusses the following issues: defence in depth principle (the role of the barriers, how does PSA represents the barriers?); the safety management and nuclear power plants; the probabilistic and deterministic approaches; the PSA applications and safety management

  18. Comparison and lessons learned from plant specific PSA of German NPP

    International Nuclear Information System (INIS)

    Balfanz, Hans-Peter; Berg, H.P.

    2000-01-01

    PSA are launched in frame of Periodic Safety Reviews (PSR) in Germany. The aims are to identify overall safety level and relative weak points. Some backfitting measures have been realized for older plants to remove relative weak points and to bring these plants to the state of the art. In this field PSA is well accepted today and is seen as a valuable tool supplementing the deterministic analysis. Main application of PSA within PSR is planned to become mandatory as part of the revision of the German Atomic Energy Act. According to the German PSA Guideline plant specific PSA level 1+ were performed for all 19 In comparison with international practice German PSA are very detailed. Otherwise they do not handle all external events, non-power states and accident management measures as discussed before. The New PSA guideline will cover these aspects and therefore analysts have to take them into account in further PSA. Moreover gathering of plant specific data is needed. The development in this field is driven by the utilities (for instance in frame of their so-called ZEDB project). Public discussion about quantitative risk of industrial hazards is quite limited in Germany and PSA results have only few impacts to this respect. Independent from this PSA for NPP is understood as a diverse tool in supporting the deterministic licensing and supervision process. Risk based decision making as well as informed regulation are just only of the beginning. State of PSA of NPP in Germany, comparison of PSA result of different NPP, German PSA guideline and state of discussion of further development and recommendation of further development of PSA of NPP are discussed in this paper in more detail. (S.Y.)

  19. Comparison and lessons learned from plant specific PSA of German NPP

    Energy Technology Data Exchange (ETDEWEB)

    Balfanz, Hans-Peter [TUEV Nord, Hamburg (Germany); Berg, H.P.

    2000-07-01

    PSA are launched in frame of Periodic Safety Reviews (PSR) in Germany. The aims are to identify overall safety level and relative weak points. Some backfitting measures have been realized for older plants to remove relative weak points and to bring these plants to the state of the art. In this field PSA is well accepted today and is seen as a valuable tool supplementing the deterministic analysis. Main application of PSA within PSR is planned to become mandatory as part of the revision of the German Atomic Energy Act. According to the German PSA Guideline plant specific PSA level 1+ were performed for all 19 In comparison with international practice German PSA are very detailed. Otherwise they do not handle all external events, non-power states and accident management measures as discussed before. The New PSA guideline will cover these aspects and therefore analysts have to take them into account in further PSA. Moreover gathering of plant specific data is needed. The development in this field is driven by the utilities (for instance in frame of their so-called ZEDB project). Public discussion about quantitative risk of industrial hazards is quite limited in Germany and PSA results have only few impacts to this respect. Independent from this PSA for NPP is understood as a diverse tool in supporting the deterministic licensing and supervision process. Risk based decision making as well as informed regulation are just only of the beginning. State of PSA of NPP in Germany, comparison of PSA result of different NPP, German PSA guideline and state of discussion of further development and recommendation of further development of PSA of NPP are discussed in this paper in more detail. (S.Y.)

  20. Long-term longitudinal changes in baseline PSA distribution and estimated prevalence of prostate cancer in male Japanese participants of population-based PSA screening.

    Science.gov (United States)

    Oki, Ryo; Ito, Kazuto; Suzuki, Rie; Fujizuka, Yuji; Arai, Seiji; Miyazawa, Yoshiyuki; Sekine, Yoshitaka; Koike, Hidekazu; Matsui, Hiroshi; Shibata, Yasuhiro; Suzuki, Kazuhiro

    2018-04-26

    Japan has experienced a drastic increase in the incidence of prostate cancer (PC). To assess changes in the risk for PC, we investigated baseline prostate specific antigen (PSA) levels in first-time screened men, across a 25-year period. In total, 72,654 men, aged 50-79, underwent first-time PSA screening in Gunma prefecture between 1992 and 2016. Changes in the distribution of PSA levels were investigated, including the percentage of men with a PSA above cut-off values and linear regression analyses comparing log 10 PSA with age. The 'ultimate incidence' of PC and clinically significant PC (CSPC) were estimated using the PC risk calculator. Changes in the age-standardized incidence rate (AIR) during this period were analyzed. The calculated coefficients of linear regression for age versus log 10 PSA fluctuated during the 25-year period, but no trend was observed. In addition, the percentage of men with a PSA above cut-off values varied in each 5-year period, with no specific trend. The 'risk calculator (RC)-based AIR' of PC and CSPC were stable between 1992 and 2016. Therefore, the baseline risk for developing PC has remained unchanged in the past 25 years, in Japan. The drastic increase in the incidence of PC, beginning around 2000, may be primarily due to increased PSA screening in the country. © 2018 UICC.

  1. Experiences of Uncertainty in Men With an Elevated PSA.

    Science.gov (United States)

    Biddle, Caitlin; Brasel, Alicia; Underwood, Willie; Orom, Heather

    2015-05-15

    A significant proportion of men, ages 50 to 70 years, have, and continue to receive prostate specific antigen (PSA) tests to screen for prostate cancer (PCa). Approximately 70% of men with an elevated PSA level will not subsequently be diagnosed with PCa. Semistructured interviews were conducted with 13 men with an elevated PSA level who had not been diagnosed with PCa. Uncertainty was prominent in men's reactions to the PSA results, stemming from unanswered questions about the PSA test, PCa risk, and confusion about their management plan. Uncertainty was exacerbated or reduced depending on whether health care providers communicated in lay and empathetic ways, and provided opportunities for question asking. To manage uncertainty, men engaged in information and health care seeking, self-monitoring, and defensive cognition. Results inform strategies for meeting informational needs of men with an elevated PSA and confirm the primary importance of physician communication behavior for open information exchange and uncertainty reduction. © The Author(s) 2015.

  2. Verification of the network flow and transport/distributed velocity (NWFT/DVM) computer code

    International Nuclear Information System (INIS)

    Duda, L.E.

    1984-05-01

    The Network Flow and Transport/Distributed Velocity Method (NWFT/DVM) computer code was developed primarily to fulfill a need for a computationally efficient ground-water flow and contaminant transport capability for use in risk analyses where, quite frequently, large numbers of calculations are required. It is a semi-analytic, quasi-two-dimensional network code that simulates ground-water flow and the transport of dissolved species (radionuclides) in a saturated porous medium. The development of this code was carried out under a program funded by the US Nuclear Regulatory Commission (NRC) to develop a methodology for assessing the risk from disposal of radioactive wastes in deep geologic formations (FIN: A-1192 and A-1266). In support to the methodology development program, the NRC has funded a separate Maintenance of Computer Programs Project (FIN: A-1166) to ensure that the codes developed under A-1192 or A-1266 remain consistent with current operating systems, are as error-free as possible, and have up-to-date documentations for reference by the NRC staff. Part of this effort would include verification and validation tests to assure that a code correctly performs the operations specified and/or is representing the processes or system for which it is intended. This document contains four verification problems for the NWFT/DVM computer code. Two of these problems are analytical verifications of NWFT/DVM where results are compared to analytical solutions. The other two are code-to-code verifications where results from NWFT/DVM are compared to those of another computer code. In all cases NWFT/DVM showed good agreement with both the analytical solutions and the results from the other code

  3. Lessons learned form IRSN review of Flamanville 3 Level PSA

    International Nuclear Information System (INIS)

    Georgescu, G.; Corenwinder, F.

    2012-01-01

    In the frame of the construction and licensing of Flamanville 3 NPP the PSA (Probabilistic Safety Assessment)plays an important role for the EPR Project assessment. The PSA was used for early design verification of EPR Reactor, several design improvement being defined based on these PSA insights and following the discussions with the French and German safety authorities. IRSN, as the French Safety Authority (ASN) technical support organization, performs the review of the PSA developed by the plant operator (EDF). The paper presents the main issues regarding the using of 'design PSA', identified by IRSN following the review of the internal events Level 1 PSA transmitted by EDF in the frame of the anticipated instruction of the application for operating license of the Flamanville 3 reactor. (authors)

  4. A Joint Report on PSA for New and Advanced Reactors

    International Nuclear Information System (INIS)

    2013-01-01

    This report addresses the application of Probabilistic Safety Assessment (PSA) to new and advanced nuclear reactors. As far as advanced reactors are concerned, the objectives were to characterize the ability of current PSA technology to address key questions regarding the development, acceptance and licensing of advanced reactor designs, to characterize the potential value of advanced PSA methods and tools for application to advanced reactors, and to develop recommendations for any needed developments regarding PSA for these reactors. As far as the design and commissioning of new nuclear power plants is concerned, the objectives were to identify and characterize current practices regarding the role of PSA, to identify key technical issues regarding PSA, lessons learned and issues requiring further work; to develop recommendations regarding the use of PSA, and to identify future international cooperative work on the identified issues. In order to reach these objectives, questionnaires had been sent to participating countries and organisations

  5. PSAPACK 4.2. A code for probabilistic safety assessment level 1. User's manual

    International Nuclear Information System (INIS)

    1995-01-01

    Only limited use has been made until now of the large amount of information contained in probabilistic safety assessments (PSAs). This is mainly due to the complexity of the PSA reports and the difficulties in obtaining intermediate results and in performing updates and recalculations. Moreover, PSA software was developed for mainframe computers, and the files of information such as fault trees and accident sequences were intended for the use of the analysts carrying out PSA studies or other skilled PSA practitioners. The increasing power and availability of personal computers (PCs) and developments in recent years in both hardware and software have made it possible to develop PSA software for use in PCs. Furthermore, the operational characteristics of PCs make them attractive not only for performing PSAs but also for updating the results and in using them in day-to-day applications. The IAEA has therefore developed in co-operation with its Member States, a software package (PSAPACK) for PCs for use in performing a Level 1 PSA and for easy interrogation of the results. Figs

  6. Performance of serum prostate-specific antigen isoform [-2]proPSA (p2PSA) and the prostate health index (PHI) in a Chinese hospital-based biopsy population.

    Science.gov (United States)

    Na, Rong; Ye, Dingwei; Liu, Fang; Chen, Haitao; Qi, Jun; Wu, Yishuo; Zhang, Guiming; Wang, Meilin; Wang, Wenying; Sun, Jielin; Yu, Guopeng; Zhu, Yao; Ren, Shancheng; Zheng, S Lilly; Jiang, Haowen; Sun, Yinghao; Ding, Qiang; Xu, Jianfeng

    2014-11-01

    The use of serum [-2]proPSA (p2PSA) and its derivative, the prostate health index (PHI), in detecting prostate cancer (PCa) have been consistently shown to have better performance than total prostate-specific antigen (tPSA) in discriminating biopsy outcomes in western countries. However, little is known about their performance in Chinese men. Our objective is to test the performance of p2PSA and PHI and their added value to tPSA in discriminating biopsy outcomes in Chinese men. Consecutive patients who underwent prostate biopsy in three tertiary hospitals in Shanghai, China during 2012-2013 were recruited. Serum tPSA, free PSA (fPSA), and p2PSA were measured centrally using Beckman Coulter's DxI 800 Immunoassay System. The primary outcome is PCa and the secondary outcome is high-grade PCa (Gleason Score of 4 + 3 or worse). Discriminative performance was assessed using the area under the receiver operating characteristic curve (AUC), detection rate and Decision Curve Analysis (DCA). Among 636 patients who underwent prostate biopsy, PHI was a significant predictor of biopsy outcomes, independent of other clinical variables. The AUC in discriminating PCa from non-PCa was consistently higher for PHI than tPSA in the entire cohort (0.88 vs. 0.81) as well as in patients with tPSA at 2-10 ng/ml (0.73 vs. 0.53), at 10.1-20 ng/ml (0.81 vs. 0.58), and at tPSA >20 ng/ml (0.90 vs. 0.80). The differences were statistically significant in all comparisons, P prostate biopsy in China. © 2014 Wiley Periodicals, Inc.

  7. Benchmarking Severe Accident Computer Codes for Heavy Water Reactor Applications

    International Nuclear Information System (INIS)

    2013-12-01

    Requests for severe accident investigations and assurance of mitigation measures have increased for operating nuclear power plants and the design of advanced nuclear power plants. Severe accident analysis investigations necessitate the analysis of the very complex physical phenomena that occur sequentially during various stages of accident progression. Computer codes are essential tools for understanding how the reactor and its containment might respond under severe accident conditions. The IAEA organizes coordinated research projects (CRPs) to facilitate technology development through international collaboration among Member States. The CRP on Benchmarking Severe Accident Computer Codes for HWR Applications was planned on the advice and with the support of the IAEA Nuclear Energy Department's Technical Working Group on Advanced Technologies for HWRs (the TWG-HWR). This publication summarizes the results from the CRP participants. The CRP promoted international collaboration among Member States to improve the phenomenological understanding of severe core damage accidents and the capability to analyse them. The CRP scope included the identification and selection of a severe accident sequence, selection of appropriate geometrical and boundary conditions, conduct of benchmark analyses, comparison of the results of all code outputs, evaluation of the capabilities of computer codes to predict important severe accident phenomena, and the proposal of necessary code improvements and/or new experiments to reduce uncertainties. Seven institutes from five countries with HWRs participated in this CRP

  8. Quality of the current low power and shutdown PSA practice

    International Nuclear Information System (INIS)

    Jang, Seung Cheol; Park, Jin Hee; Lim, Ho Gon; Kim, Tae Woon

    2004-01-01

    A probabilistic safety assessment (PSA) for the low-power and shutdown (LPSD) modes in a Korea standard nuclear power plant (KSNP) has been performed for the purpose of estimating the LPSD risk and identifying the vulnerabilities of LPSD operations. Both the operational experience and PSA results indicate that the risks from LPSD operations could be comparable with those from power operations. However, the application of the LPSD risk insights to risk-informed decision making has been slow to be adopted in practice. It is largely due to the question of whether the current LPSD PSA practice is appropriate for application to risk-informed decision making or not. Such a question has to do with the quality of the current LPSD PSA practice. In this paper, we have performed self-assessment of the KSNP LPSD PSA quality based on the ANS Standard (draft as of 13 Sep. 2002). The aims of the work are to find the LPSD PSA technical areas insufficient for application to risk-informed decision making and to efficiently allocate the limited research resources to improve the LPSD PSA model quality. Many useful findings regarding the current LPSD PSA quality are presented in this paper

  9. Development of the IPRO-zone for fire PSA and its applications

    International Nuclear Information System (INIS)

    Kang, D. I.; Han, S. H.

    2012-01-01

    A PSA analyst has been manually determining fire-induced component failure modes and modeling them into the PSA logics. These can be difficult and time-consuming tasks as they need much information and many events are to be modeled. KAERI has been developing the IPRO-ZONE (interface program for constructing zone effect table) to facilitate fire PSA works for identifying and modeling fire-induced component failure modes, and to construct a one top fire event PSA model. With the output of the IPRO-ZONE, the AIMS-PSA, and internal event one top PSA model, one top fire events PSA model is automatically constructed. The outputs of the IPRO-ZONE include information on fire zones/fire scenarios, fire propagation areas, equipment failure modes affected by a fire, internal PSA basic events corresponding to fire-induced equipment failure modes, and fire events to be modeled. This paper introduces the IPRO-ZONE, and its application results to fire PSA of Ulchin Unit 3 and SMART(System-integrated Modular Advanced Reactor). (authors)

  10. Development of the IPRO-zone for fire PSA and its applications

    Energy Technology Data Exchange (ETDEWEB)

    Kang, D. I.; Han, S. H. [Integrated Safety Assessment Div., Korea Atomic Energy Research Inst. KAERI, 1045 Daedeokdaero (150 Deokjin-Dong), Yuseong-Gu, Daejon, 305-353 (Korea, Republic of)

    2012-07-01

    A PSA analyst has been manually determining fire-induced component failure modes and modeling them into the PSA logics. These can be difficult and time-consuming tasks as they need much information and many events are to be modeled. KAERI has been developing the IPRO-ZONE (interface program for constructing zone effect table) to facilitate fire PSA works for identifying and modeling fire-induced component failure modes, and to construct a one top fire event PSA model. With the output of the IPRO-ZONE, the AIMS-PSA, and internal event one top PSA model, one top fire events PSA model is automatically constructed. The outputs of the IPRO-ZONE include information on fire zones/fire scenarios, fire propagation areas, equipment failure modes affected by a fire, internal PSA basic events corresponding to fire-induced equipment failure modes, and fire events to be modeled. This paper introduces the IPRO-ZONE, and its application results to fire PSA of Ulchin Unit 3 and SMART(System-integrated Modular Advanced Reactor). (authors)

  11. Development of a Base Model for the New Fire PSA Training

    International Nuclear Information System (INIS)

    Kim, Kilyoo; Kang, Daeil; Kim, Wee Kyong; Do, Kyu Sik

    2013-01-01

    US NRC/EPRI issued a new fire PSA method represented by NUREG/CR 6850, and have been training many operators and inspectors to widely spread the new method. However, there is a limitation in time and efficiency for many foreigners, who generally have communication problem, to participate in the EPRI/NRC training to learn the new method. Since it is about time to introduce the new fire PSA method as a regulatory requirement for the fire protection in Korea, a simple and easy-understandable base model for the fire PSA training is required, and KAERI-KINS is jointly preparing the base model for the new fire PSA training. This paper describes how the base model is developed. Using an imaginary simple NPP, a base model of fire PSA following the new fire PSA method was developed in two ways from the internal PSA model. Since we have the base model and know the process of making the fire PSA model, the training for the new fire PSA method can be in detail performed in Korea

  12. Analytic expressions for the construction of a fire event PSA model

    International Nuclear Information System (INIS)

    Kang, Dae Il; Kim, Kil Yoo; Kim, Dong San; Hwang, Mee Jeong; Yang, Joon Eon

    2016-01-01

    In this study, the changing process of an internal event PSA model to a fire event PSA model is analytically presented and discussed. Many fire PSA models have fire induced initiating event fault trees not shown in an internal event PSA model. Fire-induced initiating fault tree models are developed for addressing multiple initiating event issues. A single fire event within a fire compartment or fire scenario can cause multiple initiating events. As an example, a fire in a turbine building area can cause a loss of the main feed-water and loss of off-site power initiating events. Up to now, there has been no analytic study on the construction of a fire event PSA model using an internal event PSA model with fault trees of initiating events. In this paper, the changing process of an internal event PSA model to a fire event PSA model was analytically presented and discussed. This study results show that additional cutsets can be obtained if the fault trees of initiating events for a fire event PSA model are not exactly developed.

  13. Analytic expressions for the construction of a fire event PSA model

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Dae Il; Kim, Kil Yoo; Kim, Dong San; Hwang, Mee Jeong; Yang, Joon Eon [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In this study, the changing process of an internal event PSA model to a fire event PSA model is analytically presented and discussed. Many fire PSA models have fire induced initiating event fault trees not shown in an internal event PSA model. Fire-induced initiating fault tree models are developed for addressing multiple initiating event issues. A single fire event within a fire compartment or fire scenario can cause multiple initiating events. As an example, a fire in a turbine building area can cause a loss of the main feed-water and loss of off-site power initiating events. Up to now, there has been no analytic study on the construction of a fire event PSA model using an internal event PSA model with fault trees of initiating events. In this paper, the changing process of an internal event PSA model to a fire event PSA model was analytically presented and discussed. This study results show that additional cutsets can be obtained if the fault trees of initiating events for a fire event PSA model are not exactly developed.

  14. Concatenated codes for fault tolerant quantum computing

    Energy Technology Data Exchange (ETDEWEB)

    Knill, E.; Laflamme, R.; Zurek, W.

    1995-05-01

    The application of concatenated codes to fault tolerant quantum computing is discussed. We have previously shown that for quantum memories and quantum communication, a state can be transmitted with error {epsilon} provided each gate has error at most c{epsilon}. We show how this can be used with Shor`s fault tolerant operations to reduce the accuracy requirements when maintaining states not currently participating in the computation. Viewing Shor`s fault tolerant operations as a method for reducing the error of operations, we give a concatenated implementation which promises to propagate the reduction hierarchically. This has the potential of reducing the accuracy requirements in long computations.

  15. Serum PSA levels in the Indian population: Is it different?

    Science.gov (United States)

    Agrawal, Amit; Karan, Shailesh Chandra

    2017-04-01

    Serum prostate-specific antigen (PSA) is an important tumour, marker which is widely used to trigger trans-rectal ultrasound (TRUS)-guided prostate biopsy. However, the PSA levels vary with race and ethnicity. Therefore, there is a need to have an Indian reference range. All adult male patients meeting the inclusion and exclusion criteria were enrolled in this study. They were subjected to assessment of serum total PSA, digital rectal examination and trans-abdominal ultrasound. If any one or more of these were found abnormal, then a TRUS-guided 12-core prostate biopsy was done. Patients who were detected to have prostatic cancer were excluded from the final analysis. The data so obtained was grouped among the following three age groups: 40-49, 50-59 and 60-70 years, and the age-specific PSA values, prostatic volume and PSA density were found. A total of 1772 patients were analysed. The mean serum total PSA was 1.76 ng/ml with a standard deviation of 2.566 ng/ml. Group-wise age distribution of the mean serum total PSA was 1.22, 1.97 and 2.08 ng/ml in 40-49, 50-59 and 60-70 years age groups. The mean total PSA and the age-specific PSA range tend to be lower in the Indians than the Western population.

  16. Safety Goal, Multi-unit Risk and PSA Uncertainty

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Joon-Eon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    The safety goal is an answer of each country to the question 'How safe is safe enough?'. Table 1 shows some examples of the safety goal. However, many countries including Korea do not have the official safety goal for NPPs up to now since the establishment of safety goal is not just a technical issue but a very complex socio-technical issue. In establishing the safety goal for nuclear facilities, we have to consider various factors including not only technical aspects but also social, cultural ones. Recently, Korea is trying to establish the official safety goal. In this paper, we will review the relationship between the safety goal and Probabilistic Safety Assessment (PSA). We will also address some important technical issues to be considered in establishing the safety goal for NPPs from PSA point of view, i.e. a multi-unit risk issue and the uncertainty of PSA. In this paper, we reviewed some issues related to the safety goal and PSA. We believe that the safety goal is to be established in Korea considering the multi-unit risk. In addition, the relationship between the safety goal and PSA should be also defined clearly since PSA is the only way to answer to the question 'How safe is safe enough?'.

  17. [Rates of total and free PSA prescriptions in France (2012-2014)].

    Science.gov (United States)

    Tuppin, Philippe; Leboucher, Claire; Peyre-Lanquar, Gabrielle; Lamy, Pierre-Jean; Gabach, Pierre; Rébillard, Xavier

    2017-10-01

    In 2010, the French Haute Autorité de santé (National Health Authority) confirmed the limited value of prostate cancer (PCa) screening by total prostate-specific antigen (PSA) assay. This study was designed to determine the modalities of ordering total PSA or free PSA assays (in the absence of PCa) according to various parameters and the corresponding sums reimbursed. Men aged 40 years and older covered by the national health insurance general scheme (73% of the French population) between 2012 and 2014 were selected. Data were derived from the Système national d'information inter-régimes de l'assurance maladie (Sniiram) (National health insurance information system) database. In 2014, 27% of the 11.6 million men 40 years and older underwent at least one total PSA assay and 5.6% underwent at least one free PSA assay, with marked variations according to the presence or absence of treated lower urinary tract symptoms (LUTS) (53% and 15% vs 24% and 5%) and from one administrative department to another. The peak total PSA assay rate was observed between the ages of 65 and 74 years: 64% of men with LUTS, 46% without LUTS. Between 2012 and 2014, men in whom at least one PSA assay had been performed underwent a mean of 1.8 total PSA assays and 1.7 free PSA assays, with means of 2.3 and 2, respectively, in the presence of LUTS. General practice specialists ordered 91% of the PSA tests reimbursed in 2014 (92% for total PSA and 87% for free PSA) and urologists ordered 4% of reimbursed tests. The total sum reimbursed was €28.5 million, comprising €8.7 million for free PSA. An average of 10 laboratory tests was performed at the same time as the PSA assay in the absence of treated LUTS. Total PSA and free PSA assays are performed in a large number of men, although the value of these tests as first-line test before biopsy remains controversial. These PSA assays are associated with many other laboratory tests looking for possible abnormalities, especially in younger

  18. Study on the code system for the off-site consequences assessment of severe nuclear accident

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sora; Mn, Byung Il; Park, Ki Hyun; Yang, Byung Mo; Suh, Kyung Suk [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-12-15

    The importance of severe nuclear accidents and probabilistic safety assessment (PSA) were brought to international attention with the occurrence of severe nuclear accidents caused by the extreme natural disaster at Fukushima Daiichi nuclear power plant in Japan. In Korea, studies on level 3 PSA had made little progress until recently. The code systems of level 3 PSA, MACCS2 (MELCORE Accident Consequence Code System 2, US), COSYMA (COde SYstem from MAria, EU) and OSCAAR (Off-Site Consequence Analysis code for Atmospheric Releases in reactor accidents, JAPAN), were reviewed in this study, and the disadvantages and limitations of MACCS2 were also analyzed. Experts from Korea and abroad pointed out that the limitations of MACCS2 include the following: MACCS2 cannot simulate multi-unit accidents/release from spent fuel pools, and its atmospheric dispersion is based on a simple Gaussian plume model. Some of these limitations have been improved in the updated versions of MACCS2. The absence of a marine and aquatic dispersion model and the limited simulating range of food-chain and economic models are also important aspects that need to be improved. This paper is expected to be utilized as basic research material for developing a Korean code system for assessing off-site consequences of severe nuclear accidents.

  19. Study on the code system for the off-site consequences assessment of severe nuclear accident

    International Nuclear Information System (INIS)

    Kim, Sora; Mn, Byung Il; Park, Ki Hyun; Yang, Byung Mo; Suh, Kyung Suk

    2016-01-01

    The importance of severe nuclear accidents and probabilistic safety assessment (PSA) were brought to international attention with the occurrence of severe nuclear accidents caused by the extreme natural disaster at Fukushima Daiichi nuclear power plant in Japan. In Korea, studies on level 3 PSA had made little progress until recently. The code systems of level 3 PSA, MACCS2 (MELCORE Accident Consequence Code System 2, US), COSYMA (COde SYstem from MAria, EU) and OSCAAR (Off-Site Consequence Analysis code for Atmospheric Releases in reactor accidents, JAPAN), were reviewed in this study, and the disadvantages and limitations of MACCS2 were also analyzed. Experts from Korea and abroad pointed out that the limitations of MACCS2 include the following: MACCS2 cannot simulate multi-unit accidents/release from spent fuel pools, and its atmospheric dispersion is based on a simple Gaussian plume model. Some of these limitations have been improved in the updated versions of MACCS2. The absence of a marine and aquatic dispersion model and the limited simulating range of food-chain and economic models are also important aspects that need to be improved. This paper is expected to be utilized as basic research material for developing a Korean code system for assessing off-site consequences of severe nuclear accidents

  20. Vectorization of nuclear codes on FACOM 230-75 APU computer

    International Nuclear Information System (INIS)

    Harada, Hiroo; Higuchi, Kenji; Ishiguro, Misako; Tsutsui, Tsuneo; Fujii, Minoru

    1983-02-01

    To provide for the future usage of supercomputer, we have investigated the vector processing efficiency of nuclear codes which are being used at JAERI. The investigation is performed by using FACOM 230-75 APU computer. The codes are CITATION (3D neutron diffusion), SAP5 (structural analysis), CASCMARL (irradiation damage simulation). FEM-BABEL (3D neutron diffusion by FEM), GMSCOPE (microscope simulation). DWBA (cross section calculation at molecular collisions). A new type of cell density calculation for particle-in-cell method is also investigated. For each code we have obtained a significant speedup which ranges from 1.8 (CASCMARL) to 7.5 (GMSCOPE), respectively. We have described in this report the running time dynamic profile analysis of the codes, numerical algorithms used, program restructuring for the vectorization, numerical experiments of the iterative process, vectorized ratios, speedup ratios on the FACOM 230-75 APU computer, and some vectorization views. (author)

  1. Prodeto, a computer code for probabilistic fatigue design

    Energy Technology Data Exchange (ETDEWEB)

    Braam, H [ECN-Solar and Wind Energy, Petten (Netherlands); Christensen, C J; Thoegersen, M L [Risoe National Lab., Roskilde (Denmark); Ronold, K O [Det Norske Veritas, Hoevik (Norway)

    1999-03-01

    A computer code for structural relibility analyses of wind turbine rotor blades subjected to fatigue loading is presented. With pre-processors that can transform measured and theoretically predicted load series to load range distributions by rain-flow counting and with a family of generic distribution models for parametric representation of these distribution this computer program is available for carying through probabilistic fatigue analyses of rotor blades. (au)

  2. Development of a graphical interface computer code for reactor fuel reloading optimization

    International Nuclear Information System (INIS)

    Do Quang Binh; Nguyen Phuoc Lan; Bui Xuan Huy

    2007-01-01

    This report represents the results of the project performed in 2007. The aim of this project is to develop a graphical interface computer code that allows refueling engineers to design fuel reloading patterns for research reactor using simulated graphical model of reactor core. Besides, this code can perform refueling optimization calculations based on genetic algorithms as well as simulated annealing. The computer code was verified based on a sample problem, which relies on operational and experimental data of Dalat research reactor. This code can play a significant role in in-core fuel management practice at nuclear research reactor centers and in training. (author)

  3. Prostate-Specific Antigen (PSA) Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... medlineplus.gov/labtests/prostatespecificantigenpsatest.html Prostate-Specific Antigen (PSA) Test To use the sharing features on this ... enable JavaScript. What is a prostate-specific antigen (PSA) test? A prostate-specific antigen (PSA) test measures ...

  4. The failure mechanisms of HTR coated particle fuel and computer code

    International Nuclear Information System (INIS)

    Yang Lin; Liu Bing; Shao Youlin; Liang Tongxiang; Tang Chunhe

    2010-01-01

    The basic constituent unit of fuel element in HTR is ceramic coated particle fuel. And the performance of coated particle fuel determines the safety of HTR. In addition to the traditional detection of radiation experiments, establishing computer code is of great significance to the research. This paper mainly introduces the structure and the failure mechanism of TRISO-coated particle fuel, as well as a few basic assumptions,principles and characteristics of some existed main overseas codes. Meanwhile, this paper has proposed direction of future research by comparing the advantages and disadvantages of several computer codes. (authors)

  5. Status of computer codes available in AEOI for reactor physics analysis

    International Nuclear Information System (INIS)

    Karbassiafshar, M.

    1986-01-01

    Many of the nuclear computer codes available in Atomic Energy Organization of Iran AEOI can be used for physics analysis of an operating reactor or design purposes. Grasp of the various methods involved and practical experience with these codes would be the starting point for interesting design studies or analysis of operating conditions of presently existing and future reactors. A review of the objectives and flowchart of commonly practiced procedures in reactor physics analysis of LWRs and related computer codes was made, extrapolating to the nationally and internationally available resources. Finally, effective utilization of the existing facilities is discussed and called upon

  6. Computer simulation of variform fuel assemblies using Dragon code

    International Nuclear Information System (INIS)

    Ju Haitao; Wu Hongchun; Yao Dong

    2005-01-01

    The DRAGON is a cell code that developed for the CANDU reactor by the Ecole Polytechnique de Montreal of CANADA. Although, the DRAGON is mainly used to simulate the CANDU super-cell fuel assembly, it has an ability to simulate other geometries of the fuel assembly. However, only NEACRP benchmark problem of the BWR lattice cell was analyzed until now except for the CANDU reactor. We also need to develop the code to simulate the variform fuel assemblies, especially, for design of the advanced reactor. We validated that the cell code DRAGON is useful for simulating various kinds of the fuel assembly by analyzing the rod-shape fuel assembly of the PWR and the MTR plate-shape fuel assembly. Some other kinds of geometry of geometry were computed. Computational results show that the DRAGON is able to analyze variform fuel assembly problems and the precision is high. (authors)

  7. Real-life experience of using conventional disease-modifying anti-rheumatic drugs (DMARDs) in psoriatic arthritis (PsA). Retrospective analysis of the efficacy of methotrexate, sulfasalazine, and leflunomide in PsA in comparison to spondyloarthritides other than PsA and literature review of the use of conventional DMARDs in PsA

    Science.gov (United States)

    Roussou, Euthalia; Bouraoui, Aicha

    2017-01-01

    Objective With the aim of assessing the response to treatment with conventional disease-modifying anti-rheumatic drugs (DMARDs) used in patients with psoriatic arthritis (PsA), data on methotrexate, sulfasalazine (SSZ), and leflunomide were analyzed from baseline and subsequent follow-up (FU) questionnaires completed by patients with either PsA or other spondyloarthritides (SpAs). Material and Methods A single-center real-life retrospective analysis was performed by obtaining clinical data via questionnaires administered before and after treatment. The indices used were erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) level, Bath Ankylosing Spondylitis Disease Activity Index (BASDAI), Bath Ankylosing Spondylitis Function Index (BASFI), wellbeing (WB), and treatment effect (TxE). The indices measured at baseline were compared with those measured on one occasion in a FU visit at least 1 year later. Results A total of 73 patients, 51 with PsA (mean age 49.8±12.8 years; male-to-female ratio [M:F]=18:33) and 22 with other SpAs (mean age 50.6±16 years; M:F=2:20), were studied. BASDAI, BASFI, and WB displayed consistent improvements during FU assessments in both PsA patients and controls in comparison to baseline values. SSZ exhibited better efficacy as confirmed by TxE in both PsA patients and controls. ESR and CRP displayed no differences in either the PsA or the SpA group between the cases before and after treatment. Conclusion Real-life retrospective analysis of three DMARDs used in PsA (and SpAs other than PsA) demonstrated that all three DMARDs that were used brought about improvements in BASDAI, BASFI, TxE, and WB. However, the greatest improvements at FU were seen with SSZ use in both PsA and control cohorts. PMID:28293446

  8. A new method to consider human actions in the framework of a dynamic PSA

    International Nuclear Information System (INIS)

    Kloos, M.; Peschke, J.

    2006-01-01

    The variety of accident sequences to be considered in the framework of a PSA derives from mutual dependencies between the physical process, the behaviour of the technical system, human actions and stochastic influences along the time axis. Because the conventional PSA approach is not able to adequately account for these interactions, so-called probabilistic dynamics methods have been developed. They generally achieve a more realistic modelling of accident scenarios and a more realistic safety assessment. At GRS, the method MCDET - a combination of Monte Carlo Simulation und the Discrete Dynamic Event Tree method - was developed. The implementation of MCDET was supplemented by a so called Crew-Module which allows - together with a deterministic dynamics code - to simulate human actions as a dynamic process evolving over time in interaction with the system and process dynamics. The Crew-Module accounts for communications between crew members and for performance shaping factors like stress, knowledge or ergonomics. This paper presents the Crew- Module and gives an overview of the results which may be obtained from its combination with MCDET and a deterministic dynamics code. The emergency operating procedure 'Secondary Side Bleed and Feed' in a German PWR is selected as an illustrative application. (authors)

  9. 68Ga-PSMA PET/CT for the detection of bone metastasis in recurrent prostate cancer and a PSA level <2 ng/ml

    DEFF Research Database (Denmark)

    Petersen, Lars J; Nielsen, Julie B; Dettmann, Katja

    2017-01-01

    /computed tomography ((68)Ga-PSMA PET/CT) is a novel and promising method for imaging in prostate cancer. The present study reports two cases of patients with prostate cancer with biochemical recurrence, with evidence of bone metastases on (68)Ga-PSMA PET/CT images and low prostate specific antigen PSA levels (.../ml) and PSA doubling time >6 months. The bone metastases were verified by supplementary imaging with (18)F-sodium fluoride PET/CT and magnetic resonance imaging as well as biochemical responses to androgen deprivation therapy. Therefore, (68)Ga-PSMA PET/CT is promising for the restaging of patients...... with prostate cancer with biochemical recurrence, including patients with low PSA levels and low PSA kinetics....

  10. Variability of assay methods for total and free PSA after WHO standardization.

    Science.gov (United States)

    Foj, L; Filella, X; Alcover, J; Augé, J M; Escudero, J M; Molina, R

    2014-03-01

    The variability of total PSA (tPSA) and free PSA (fPSA) results among commercial assays has been suggested to be decreased by calibration to World Health Organization (WHO) reference materials. To characterize the current situation, it is necessary to know its impact in the critical cutoffs used in clinical practice. In the present study, we tested 167 samples with tPSA concentrations of 0 to 20 μg/L using seven PSA and six fPSA commercial assays, including Access, ARCHITECT i2000, ADVIA Centaur XP, IMMULITE 2000, Elecsys, and Lumipulse G1200, in which we only measured tPSA. tPSA and fPSA were measured in Access using the Hybritech and WHO calibrators. Passing-Bablok analysis was performed for PSA, and percentage of fPSA with the Hybritech-calibrated access comparison assay. For tPSA, relative differences were more than 10 % at 0.2 μg/L for ARCHITECT i2000, and at a critical concentration of 3, 4, and 10 μg/L, the relative difference was exceeded by ADVIA Centaur XP and WHO-calibrated Access. For percent fPSA, at a critical concentration of 10 %, the 10 % relative difference limit was exceeded by IMMULITE 2000 assay. At a critical concentration of 20 and 25 %, ADVIA Centaur XP, ARCHITECT i2000, and IMMULITE 2000 assays exceeded the 10 % relative difference limit. We have shown significant discordances between assays included in this study despite advances in standardization conducted in the last years. Further harmonization efforts are required in order to obtain a complete clinical concordance.

  11. COMPBRN III: a computer code for modeling compartment fires

    International Nuclear Information System (INIS)

    Ho, V.; Siu, N.; Apostolakis, G.; Flanagan, G.F.

    1986-07-01

    The computer code COMPBRN III deterministically models the behavior of compartment fires. This code is an improvement of the original COMPBRN codes. It employs a different air entrainment model and numerical scheme to estimate properties of the ceiling hot gas layer model. Moreover, COMPBRN III incorporates a number of improvements in shape factor calculations and error checking, which distinguish it from the COMPBRN II code. This report presents the ceiling hot gas layer model employed by COMPBRN III as well as several other modifications. Information necessary to run COMPBRN III, including descriptions of required input and resulting output, are also presented. Simulation of experiments and a sample problem are included to demonstrate the usage of the code. 37 figs., 46 refs

  12. Prostate-Specific Antigen (PSA) Bounce After Dose-Escalated External Beam Radiation Therapy Is an Independent Predictor of PSA Recurrence, Metastasis, and Survival in Prostate Adenocarcinoma Patients.

    Science.gov (United States)

    Romesser, Paul B; Pei, Xin; Shi, Weiji; Zhang, Zhigang; Kollmeier, Marisa; McBride, Sean M; Zelefsky, Michael J

    2018-01-01

    To evaluate the difference in prostate-specific antigen (PSA) recurrence-free, distant metastasis-free, overall, and cancer-specific survival between PSA bounce (PSA-B) and non-bounce patients treated with dose-escalated external beam radiation therapy (DE-EBRT). During 1990-2010, 1898 prostate adenocarcinoma patients were treated with DE-EBRT to ≥75 Gy with ≥5 years follow-up. Patients receiving neoadjuvant/concurrent androgen-deprivation therapy (n=1035) or with fewer than 4 PSA values obtained 6 months or more after post-EBRT completion (n=87) were excluded. The evaluable 776 patients were treated (median, 81.0 Gy). Prostate-specific antigen bounce was defined as a ≥0.2-ng/mL increase above the interval PSA nadir, followed by a decrease to nadir or below. Prostate-specific antigen relapse was defined as post-radiation therapy PSA nadir + 2 ng/mL. Median follow-up was 9.2 years (interquartile range, 6.9-11.3 years). One hundred twenty-three patients (15.9%) experienced PSA-B after DE-EBRT at a median of 24.6 months (interquartile range, 16.1-38.5 months). On multivariate analysis, younger age (P=.001), lower Gleason score (P=.0003), and higher radiation therapy dose (P=.0002) independently predicted PSA-B. Prostate-specific antigen bounce was independently associated with decreased risk for PSA relapse (hazard ratio [HR] 0.53; 95% confidence interval [CI] 0.33-0.85; P=.008), distant metastatic disease (HR 0.34; 95% CI 0.12-0.94; P=.04), and all-cause mortality (HR 0.53; 95% CI 0.29-0.96; P=.04) on multivariate Cox analysis. Because all 50 prostate cancer-specific deaths in patients without PSA-B were in the non-bounce cohort, competing-risks analysis was not applicable. A nonparametric competing-risks test demonstrated that patients with PSA-B had superior cancer-specific survival compared with patients without PSA-B (P=.004). Patients treated with dose-escalated radiation therapy for prostate adenocarcinoma who experience posttreatment PSA-B have

  13. ABINIT: a computer code for matter; Abinit: un code au service de la matiere

    Energy Technology Data Exchange (ETDEWEB)

    Amadon, B.; Bottin, F.; Bouchet, J.; Dewaele, A.; Jollet, F.; Jomard, G.; Loubeyre, P.; Mazevet, S.; Recoules, V.; Torrent, M.; Zerah, G. [CEA Bruyeres-le-Chatel, 91 (France)

    2008-07-01

    The PAW (Projector Augmented Wave) method has been implemented in the ABINIT Code that computes electronic structures in atoms. This method relies on the simultaneous use of a set of auxiliary functions (in plane waves) and a sphere around each atom. This method allows the computation of systems including many atoms and gives the expression of energy, forces, stress... in terms of the auxiliary function only. We have generated atomic data for iron at very high pressure (over 200 GPa). We get a bcc-hcp transition around 10 GPa and the magnetic order disappears around 50 GPa. This method has been validated on a series of metals. The development of the PAW method has required a great effort for the massive parallelization of the ABINIT code. (A.C.)

  14. The inverse relationship between prostate-specific antigen (PSA) and obesity.

    Science.gov (United States)

    Aref, Adel; Vincent, Andrew D; O'Callaghan, Michael; Martin, Sean; Sutherland, Peter; Hoy, Andrew; Butler, Lisa M; Wittert, Gary

    2018-06-25

    Obese men have lower serum prostate-specific antigen (PSA) than comparably aged lean men, but the underlying mechanism remains unclear. The aim of this study was to determine the effect of obesity on PSA and the potential contributing mechanisms. A cohort of 1195 men aged 35 years and over at recruitment, with demographic, anthropometric (body mass index (BMI), waist circumference (WC)) and serum hormone (serum testosterone (T), estradiol (E2)), PSA and hematology assessments obtained over two waves was assessed. Men with a history of prostate cancer or missing PSA were excluded, leaving 970 men for the final analysis. Mixed-effects regressions and mediation analyses adjusting for hormonal and volumetric factors explore the potential mechanisms relating obesity to PSA. After adjusting for age, PSA levels were lower in men with greater WC (p=0.001). In a multivariable model including WC, age, E2/T and PlasV as predictors, no statistically significant associations were observed between with PSA and either WC (p=0.36) or PlasV (p=0.49), while strong associations were observed with both E2/T (pPSA (p=0.31), while when E2/T is a mediator; the ACME explained roughly 0.5 of the effect (pPSA levels in obese men, as compared to normal weight men, can be explained both by hormonal changes (elevated E2/T ratio) and haemodilution. Hormonal factors therefore represent a substantial but underappreciated mediating pathway.

  15. The use of PSA in the French regulatory practice

    International Nuclear Information System (INIS)

    Mennesiez, H.

    1994-01-01

    The presentation gives a description of fundamental documents (since 1977-1978) through which have been set up in France probabilistic objectives, and PSAs, including shutdown states, performed for 900-1300 MWe PWR-type nuclear power plants. PSA developments and use, including fire PSA, level 2 and PSA for the future French-German European Pressurized Reactor (EPR) are also discussed

  16. Methodology for fire PSA during design process

    International Nuclear Information System (INIS)

    Kollasko, Heiko; Blombach, Joerg

    2009-01-01

    Fire PSA is an essential part of a full scope level 1 PSA. Cable fires play an important role in fire PSA. Usually, cable routing is therefore modeled in detail. During the design of new nuclear power plants the information on cable routing is not yet available. However, for the use of probabilistic safety insights during the design and for licensing purposes a fire PSA may be requested. Therefore a methodology has been developed which makes use of the strictly divisional separation of redundancies in the design of modern nuclear power plants: cable routing is not needed within one division but replaced by the conservative assumption that all equipment fails due to a fire in the concerned division; critical fire areas are defined where components belonging to different divisions may be affected by a fire. For the determination of fire frequencies a component based approach is proposed. The resulting core damage frequencies due to fire are conservative. (orig.)

  17. Calculations of reactor-accident consequences, Version 2. CRAC2: computer code user's guide

    International Nuclear Information System (INIS)

    Ritchie, L.T.; Johnson, J.D.; Blond, R.M.

    1983-02-01

    The CRAC2 computer code is a revision of the Calculation of Reactor Accident Consequences computer code, CRAC, developed for the Reactor Safety Study. The CRAC2 computer code incorporates significant modeling improvements in the areas of weather sequence sampling and emergency response, and refinements to the plume rise, atmospheric dispersion, and wet deposition models. New output capabilities have also been added. This guide is to facilitate the informed and intelligent use of CRAC2. It includes descriptions of the input data, the output results, the file structures, control information, and five sample problems

  18. Prostate-specific antigen (PSA) density in the diagnostic algorithm of prostate cancer.

    Science.gov (United States)

    Nordström, Tobias; Akre, Olof; Aly, Markus; Grönberg, Henrik; Eklund, Martin

    2018-04-01

    Screening for prostate cancer using prostate-specific antigen (PSA) alone leads to un-necessary biopsying and overdiagnosis. PSA density is easily accessible, but early evidence on its use for biopsy decisions was conflicting and use of PSA density is not commonly recommended in guidelines. We analyzed biopsy outcomes in 5291 men in the population-based STHLM3 study with PSA ≥ 3 ng/ml and ultrasound-guided prostate volume measurements by using percentages and regression models. PSA density was calculated as total PSA (ng/ml) divided by prostate volume (ml). Main endpoint was clinically significant cancer (csPCa) defined as Gleason Score ≥ 7. The median PSA-density was 0.10 ng/ml 2 (IQR 0.075-0.14). PSA-density was associated with the risk of finding csPCa both with and without adjusting for the additional clinical information age, family history, previous biopsies, total PSA and free/total PSA (OR 1.06; 95% CI:1.05-1.07 and OR 1.07, 95% CI 1.06-1.08). Discrimination for csPCa was better when PSA density was added to a model with additional clinical information (AUC 0.75 vs. 0.73, P PSA-density. Omitting prostate biopsy for men with PSA-density ≤0.07 ng/ml 2 would save 19.7% of biopsy procedures, while missing 6.9% of csPCa. PSA-density cutoffs of 0.10 ng/ml 2 and 0.15 ng/ml 2 resulted in detection of 77% (729/947) and 49% (461/947) of Gleason Score ≥7 tumors. PSA-density might inform biopsy decisions, and spare some men from the morbidity associated with a prostate biopsy and diagnosis of low-grade prostate cancer.

  19. Involvement of Union Fenosa skills in the thermohydraulic area of the Jose Cabrera NPP PSA. Applications of the RELAPS5/MOD2 Code; Implicacion de las capacidades de union fenosa dentro del area de termohidraulica en el APS de la C.N. Jose Cabrera. Aplicaciones del codigo RELAP5/MOD2

    Energy Technology Data Exchange (ETDEWEB)

    Martin, L; Saenz Tejada, P [Empresarios Agrupados, A.I.E., Madrid (Spain)

    1993-12-15

    When performing a level 1 Probabilistic Safety Analysis (PSA) on a standard power plant, in order to model plant response to the potential occurrence of the various initiating events postulated in a PSA, reference documentation applicable to the type of plant in question is frequently consulted. Because of the specific design characteristics of the Jose Cabrera NPP, most of the reference documentation for the W-PWR-type power plants is not applicable to this plant. To fill in these gaps in the documentation and to construct the most realistic model of plant behaviour possible, assistance was sought from Union Fenosa by way of infrastructure, capabilities and thermohydraulic experience of the Nuclear Engineering and Fuel Group, and especially the use of calculations performed with the RELAP5/ MOD2 code. This paper will provide an overview of the general assistance rendered to the PSA by the technical experts in thermohydraulics, the calculations performed with RELAP5/MOD2 and the influence all of this has had on the development, quality and results of the Jose Cabrera NPP level 1 PSA Project. (author)

  20. Risk Metrics and Measures for an Extended PSA

    International Nuclear Information System (INIS)

    Wielenberg, A.; Loeffler, H.; Hasnaoui, C.; Burgazzi, L.; Cazzoli, E.; Jan, P.; La Rovere, S.; Siklossy, T.; Vitazkova, J.; Raimond, E.

    2016-01-01

    This report provides a review of the main used risk measures for Level 1 and Level 2 PSA. It depicts their advantages, limitations and disadvantages and develops some more precise risk measures relevant for extended PSAs and helpful for decision-making. This report does not recommend or suggest any quantitative value for the risk measures. It does not discuss in details decision-making based on PSA results neither. The choice of one appropriate risk measure or a set of risk measures depends on the decision making approach as well as on the issue to be decided. The general approach for decision making aims at a multi-attribute approach. This can include the use of several risk measures as appropriate. Section 5 provides some recommendations on the main risk metrics to be used for an extended PSA. For Level 1 PSA, Fuel Damage Frequency and Radionuclide Mobilization Frequency are recommended. For Level 2 PSA, the characterization of loss of containment function and a total risk measure based on the aggregated activity releases of all sequences rated by their frequencies is proposed. (authors)

  1. Present state of the SOURCES computer code

    International Nuclear Information System (INIS)

    Shores, Erik F.

    2002-01-01

    In various stages of development for over two decades, the SOURCES computer code continues to calculate neutron production rates and spectra from four types of problems: homogeneous media, two-region interfaces, three-region interfaces and that of a monoenergetic alpha particle beam incident on a slab of target material. Graduate work at the University of Missouri - Rolla, in addition to user feedback from a tutorial course, provided the impetus for a variety of code improvements. Recently upgraded to version 4B, initial modifications to SOURCES focused on updates to the 'tape5' decay data library. Shortly thereafter, efforts focused on development of a graphical user interface for the code. This paper documents the Los Alamos SOURCES Tape1 Creator and Library Link (LASTCALL) and describes additional library modifications in more detail. Minor improvements and planned enhancements are discussed.

  2. Framework for ensuring appropriate maintenance of baseline PSA and risk monitor models in a nuclear power plant

    International Nuclear Information System (INIS)

    Vrbanic, I.; Sorman, J.

    2005-01-01

    The necessity of observing both long term and short term risk changes many times imposes the need for a nuclear power plant to have a baseline PSA model to produce an estimate of long term averaged risk and a risk monitor to produce a time-dependent risk curve and/or safety functions status at points in time or over a shorter time period of interest. By nature, a baseline PSA reflects plant systems and operation in terms of average conditions and provides time-invariant quantitative risk metrics. Risk monitor, on the other hand, requires condition-specific modeling to produce a quantitative and/or qualitative estimate of plant's condition-specific risk metrics. While risk monitor is used for computing condition-specific risk metrics over time, a baseline PSA model is needed for variety of other risk oriented applications, such as assessments of proposed design modifications or risk ranking of equipment. Having in mind their importance and roles, it is essential that both models, i.e. baseline PSA model and risk monitor are maintained in the way that they represent, as accurately as practically achievable, the actual plant status (e.g. systems' design and plant's procedures in effect) and its history (e.g. numbers of equipment failures and demands that influence relevant PSA parameters). Paper discusses the requirements for appropriate maintenance of plant's baseline PSA model and risk monitor model and presents the framework for plant's engineering and administrative procedures that would ensure they are met. (author)

  3. Theory of the space-dependent fuel management computer code ''UAFCC''

    International Nuclear Information System (INIS)

    El-Meshad, Y.; Morsy, S.; El-Osery, I.A.

    1981-01-01

    This report displays the theory of the spatial burnup computer code ''UAFCC'' which has been constructed as a part of an integrated reactor calculation scheme proposed at the Reactors Department of the ARE Atomic Energy Authority. The ''UAFCC'' is a single energy-one-dimensional diffusion burnup FORTRAN computer code for well moderated, multiregion, cylindrical thermal reactors. The effect of reactivity variation with burnup is introduced in the steady state diffusion equation by a fictitious neutron source. The infinite multiplication factor, the total migration area, and the power density per unit thermal flux are calculated from the point model burnup code ''UABUC'' fitted to polynomials of suitable degree in the flux-time, and then used as an input data to the ''UAFCC'' code. The proposed burnup spatial model has been used to study the different stratogemes of the incore fuel management schemes. The conclusions of this study will be presented in a future publication. (author)

  4. Updating the Psoriatic Arthritis (PsA) Core Domain Set

    DEFF Research Database (Denmark)

    Orbai, Ana-Maria; de Wit, Maarten; Mease, Philip J

    2017-01-01

    OBJECTIVE: To include the patient perspective in accordance with the Outcome Measures in Rheumatology (OMERACT) Filter 2.0 in the updated Psoriatic Arthritis (PsA) Core Domain Set for randomized controlled trials (RCT) and longitudinal observational studies (LOS). METHODS: At OMERACT 2016, research...... conducted to update the PsA Core Domain Set was presented and discussed in breakout groups. The updated PsA Core Domain Set was voted on and endorsed by OMERACT participants. RESULTS: We conducted a systematic literature review of domains measured in PsA RCT and LOS, and identified 24 domains. We conducted...... and breakout groups at OMERACT 2016 in which findings were presented and discussed. The updated PsA Core Domain Set endorsed with 90% agreement by OMERACT 2016 participants included musculoskeletal disease activity, skin disease activity, fatigue, pain, patient's global assessment, physical function, health...

  5. Three computer codes for safety and stability of large superconducting magnets

    International Nuclear Information System (INIS)

    Turner, L.R.

    1985-01-01

    For analyzing the safety and stability of large superconducting magnets, three computer codes TASS, SHORTURN, and SSICC have been developed, applicable to bath-cooled magnets, bath-cooled magnets with shorted turns, and magnets with internally cooled conductors respectively. The TASS code is described, and the use of the three codes is reviewed

  6. Development of Integrated PSA Database and Application Technology

    Energy Technology Data Exchange (ETDEWEB)

    Han, Sang Hoon; Park, Jin Hee; Kim, Seung Hwan; Choi, Sun Yeong; Jung, Woo Sik; Jeong, Kwang Sub; Ha Jae Joo; Yang, Joon Eon; Min Kyung Ran; Kim, Tae Woon

    2005-04-15

    The purpose of this project is to develop 1) the reliability database framework, 2) the methodology for the reactor trip and abnormal event analysis, and 3) the prototype PSA information DB system. We already have a part of the reactor trip and component reliability data. In this study, we extend the collection of data up to 2002. We construct the pilot reliability database for common cause failure and piping failure data. A reactor trip or a component failure may have an impact on the safety of a nuclear power plant. We perform the precursor analysis for such events that occurred in the KSNP, and to develop a procedure for the precursor analysis. A risk monitor provides a mean to trace the changes in the risk following the changes in the plant configurations. We develop a methodology incorporating the model of secondary system related to the reactor trip into the risk monitor model. We develop a prototype PSA information system for the UCN 3 and 4 PSA models where information for the PSA is inputted into the system such as PSA reports, analysis reports, thermal-hydraulic analysis results, system notebooks, and so on. We develop a unique coherent BDD method to quantify a fault tree and the fastest fault tree quantification engine FTREX. We develop quantification software for a full PSA model and a one top model.

  7. CRACKEL: a computer code for CFR fuel management calculations

    International Nuclear Information System (INIS)

    Burstall, R.F.; Ball, M.A.; Thornton, D.E.J.

    1975-12-01

    The CRACKLE computer code is designed to perform rapid fuel management surveys of CFR systems. The code calculates overall features such as reactivity, power distributions and breeding gain, and also calculates for each sub-assembly plutonium content and power output. A number of alternative options are built into the code, in order to permit different fuel management strategies to be calculated, and to perform more detailed calculations when necessary. A brief description is given of the methods of calculation, and the input facilities of CRACKLE, with examples. (author)

  8. Qualification of FEAST 3.0 and FEAT 4.0 computer codes

    International Nuclear Information System (INIS)

    Xu, Z.; Lai, L.; Sim, K.-S.; Huang, F.; Wong, B.

    2005-01-01

    FEAST (Finite Element Analysis for Stresses) is an AECL computer code used to assess the structural integrity of the CANDU fuel element. FEAST models the thermo-elastic, thermo-elasto-plastic and creep deformations in CANDU fuel. FEAT (Finite Element Analysis for Temperature) is another AECL computer code and is used to assess the thermal integrity of fuel elements. FEAT models the steady-state and transient heat flows in CANDU fuel, under conditions such as flux depression, end flux peaking, temperature-dependent thermal conductivity, and non-uniform time-dependent boundary conditions. Both computer programs are used in design and qualification analyses of CANDU fuel. Formal qualifications (including coding verification and validation) of both codes were performed, in accordance with AECL software quality assurance (SQA) manual and procedures that are consistent with CSA N286.7-99. Validation of FEAST 3.0 shows very good agreement with independent analytical solutions or measurements. Validation of FEAT 4.0 also shows very good agreement with independent WIMS-AECL calculations, analytical solutions, ANSYS calculations and measurement. (author)

  9. Qualification of FEAST 3.0 and FEAT 4.0 computer codes

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Z.; Lai, L.; Sim, K.-S.; Huang, F.; Wong, B. [Atomic Energy of Canada Limited, Mississauga, Ontario (Canada)

    2005-07-01

    FEAST (Finite Element Analysis for Stresses) is an AECL computer code used to assess the structural integrity of the CANDU fuel element. FEAST models the thermo-elastic, thermo-elasto-plastic and creep deformations in CANDU fuel. FEAT (Finite Element Analysis for Temperature) is another AECL computer code and is used to assess the thermal integrity of fuel elements. FEAT models the steady-state and transient heat flows in CANDU fuel, under conditions such as flux depression, end flux peaking, temperature-dependent thermal conductivity, and non-uniform time-dependent boundary conditions. Both computer programs are used in design and qualification analyses of CANDU fuel. Formal qualifications (including coding verification and validation) of both codes were performed, in accordance with AECL software quality assurance (SQA) manual and procedures that are consistent with CSA N286.7-99. Validation of FEAST 3.0 shows very good agreement with independent analytical solutions or measurements. Validation of FEAT 4.0 also shows very good agreement with independent WIMS-AECL calculations, analytical solutions, ANSYS calculations and measurement. (author)

  10. PSAPACK 4.2. A code for probabilistic safety assessment level 1. User`s manual

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-03-01

    Only limited use has been made until now of the large amount of information contained in probabilistic safety assessments (PSAs). This is mainly due to the complexity of the PSA reports and the difficulties in obtaining intermediate results and in performing updates and recalculations. Moreover, PSA software was developed for mainframe computers, and the files of information such as fault trees and accident sequences were intended for the use of the analysts carrying out PSA studies or other skilled PSA practitioners. The increasing power and availability of personal computers (PCs) and developments in recent years in both hardware and software have made it possible to develop PSA software for use in PCs. Furthermore, the operational characteristics of PCs make them attractive not only for performing PSAs but also for updating the results and in using them in day-to-day applications. The IAEA has therefore developed in co-operation with its Member States, a software package (PSAPACK) for PCs for use in performing a Level 1 PSA and for easy interrogation of the results. Figs.

  11. Predictive value of [-2]propsa (p2psa and its derivatives for the prostate cancer detection in the 2.0 to 10.0ng/mL PSA range

    Directory of Open Access Journals (Sweden)

    I. Vukovic

    Full Text Available ABSTRACT Introduction To assess predictive value of new tumor markers, precursor of prostate specific antigen (p2PSA and its derivates-%p2PSA and prostate health index (PHI in detection of patients with indolent and aggressive prostate cancer (PC in a subcohort of man whose total PSA ranged from 2 to 10ng/mL. Materials and Methods This cross-sectional study included 129 consecutive male patients aged over 50 years, with no previous history of PC and with normal digital rectal examination findings, but with serum PSA in interval between 2 and 10ng/mL. All patients underwent standard transrectal ultrasonography guided prostate biopsy for the first time. For all patients, serum PSA, free PSA (fPSA and p2PSA were measured and PHI and %p2PSA were calculated. Results PHI and %p2PSA levels were significanlty higher in patients with PC compared to those without this malignancy. The same findings have been observed in group of patients with Gleason score ≥7 compared to those with Gleason score <7. ROC analysis reveled the highest area under the curve with these two markers. Multivariate logistic regression showed significant improvement in PC detection and its agressive form (assumed as Gleason score ≥7. Conclusions New markers, derivates of p2PSA (especially %p2PSA and PHI, represente potentially very important clinical tool for predicting presence of PC, and even more important, to discriminate patients with Gleason score <7 from those with Gleason score ≥7 with total PSA in range from 2 to 10ng/mL.

  12. Predictive value of [-2]propsa (p2psa) and its derivatives for the prostate cancer detection in the 2.0 to 10.0ng/mL PSA range.

    Science.gov (United States)

    Vukovic, I; Djordjevic, D; Bojanic, N; Babic, U; Soldatovic, I

    2017-01-01

    To assess predictive value of new tumor markers, precursor of prostate specific antigen (p2PSA) and its derivates-%p2PSA and prostate health index (PHI) in detection of patients with indolent and aggressive prostate cancer (PC) in a subcohort of man whose total PSA ranged from 2 to 10ng/mL. This cross-sectional study included 129 consecutive male patients aged over 50 years, with no previous history of PC and with normal digital rectal examination findings, but with serum PSA in interval between 2 and 10ng/mL. All patients underwent standard transrectal ultrasonography guided prostate biopsy for the first time. For all patients, serum PSA, free PSA (fPSA) and p2PSA were measured and PHI and %p2PSA were calculated. PHI and %p2PSA levels were significanlty higher in patients with PC compared to those without this malignancy. The same findings have been observed in group of patients with Gleason score ≥7 compared to those with Gleason score <7. ROC analysis reveled the highest area under the curve with these two markers. Multivariate logistic regression showed significant improvement in PC detection and its agressive form (assumed as Gleason score ≥7). New markers, derivates of p2PSA (especially %p2PSA and PHI), represente potentially very important clinical tool for predicting presence of PC, and even more important, to discriminate patients with Gleason score <7 from those with Gleason score ≥7 with total PSA in range from 2 to 10ng/mL. Copyright® by the International Brazilian Journal of Urology.

  13. Description of the TREBIL, CRESSEX and STREUSL computer programs, that belongs to RALLY computer code pack for the analysis of reliability systems

    International Nuclear Information System (INIS)

    Fernandes Filho, T.L.

    1982-11-01

    The RALLY computer code pack (RALLY pack) is a set of computer codes destinate to the reliability of complex systems, aiming to a risk analysis. Three of the six codes, are commented, presenting their purpose, input description, calculation methods and results obtained with each one of those computer codes. The computer codes are: TREBIL, to obtain the fault tree logical equivalent; CRESSEX, to obtain the minimal cut and the punctual values of the non-reliability and non-availability of the system; and STREUSL, for the dispersion calculation of those values around the media. In spite of the CRESSEX, in its version available at CNEN, uses a little long method to obtain the minimal cut in an HB-CNEN system, the three computer programs show good results, mainly the STREUSL, which permits the simulation of various components. (E.G.) [pt

  14. Reducing Computational Overhead of Network Coding with Intrinsic Information Conveying

    DEFF Research Database (Denmark)

    Heide, Janus; Zhang, Qi; Pedersen, Morten V.

    is RLNC (Random Linear Network Coding) and the goal is to reduce the amount of coding operations both at the coding and decoding node, and at the same time remove the need for dedicated signaling messages. In a traditional RLNC system, coding operation takes up significant computational resources and adds...... the coding operations must be performed in a particular way, which we introduce. Finally we evaluate the suggested system and find that the amount of coding can be significantly reduced both at nodes that recode and decode.......This paper investigated the possibility of intrinsic information conveying in network coding systems. The information is embedded into the coding vector by constructing the vector based on a set of predefined rules. This information can subsequently be retrieved by any receiver. The starting point...

  15. Development and validation of GWHEAD, a three-dimensional groundwater head computer code

    International Nuclear Information System (INIS)

    Beckmeyer, R.R.; Root, R.W.; Routt, K.R.

    1980-03-01

    A computer code has been developed to solve the groundwater flow equation in three dimensions. The code has finite-difference approximations solved by the strongly implicit solution procedure. Input parameters to the code include hydraulic conductivity, specific storage, porosity, accretion (recharge), and initial hydralic head. These parameters may be input as varying spatially. The hydraulic conductivity may be input as isotropic or anisotropic. The boundaries either may permit flow across them or may be impermeable. The code has been used to model leaky confined groundwater conditions and spherical flow to a continuous point sink, both of which have exact analytical solutions. The results generated by the computer code compare well with those of the analytical solutions. The code was designed to be used to model groundwater flow beneath fuel reprocessing and waste storage areas at the Savannah River Plant

  16. PSA LEVEL 3 DAN IMPLEMENTASINYA PADA KAJIAN KESELAMATAN PWR

    Directory of Open Access Journals (Sweden)

    Pande Made Udiyani

    2015-03-01

    Full Text Available Kajian keselamatan PLTN menggunakan metodologi kajian probabilistik sangat penting selain kajian deterministik. Metodologi kajian menggunakan Probabilistic Safety Assessment (PSA Level 3 diperlukan terutama untuk estimasi kecelakaan parah atau kecelakaan luar dasar desain PLTN. Metode ini banyak dilakukan setelah kejadian kecelakaan Fukushima. Dalam penelitian ini dilakukan implementasi PSA Level 3 pada kajian keselamatan PWR, postulasi kecelakan luar dasar desain PWR AP-1000 dan disimulasikan di contoh tapak Bangka Barat. Rangkaian perhitungan yang dilakukan adalah: menghitung suku sumber dari kegagalan teras yang terjadi, pemodelan kondisi meteorologi tapak dan lingkungan, pemodelan jalur paparan, analisis dispersi radionuklida dan transportasi fenomena di lingkungan, analisis deposisi radionuklida, analisis dosis radiasi, analisis perlindungan & mitigasi, dan analisis risiko. Kajian menggunakan rangkaian subsistem pada perangkat lunak PC Cosyma. Hasil penelitian membuktikan bahwa implementasi metode kajian keselamatan PSA Level 3 sangat efektif dan komprehensif terhadap estimasi dampak, konsekuensi, risiko, kesiapsiagaan kedaruratan nuklir (nuclear emergency preparedness, dan manajemen kecelakaan reaktor terutama untuk kecelakaan parah atau kecelakaan luar dasar desain PLTN. Hasil kajian dapat digunakan sebagai umpan balik untuk kajian keselamatan PSA Level 1 dan PSA Level 2. Kata kunci: PSA level 3, kecelakaan, PWR   Reactor safety assessment of nuclear power plants using probabilistic assessment methodology is most important in addition to the deterministic assessment. The methodology of Level 3 Probabilistic Safety Assessment (PSA is especially required to estimate severe accident or beyond design basis accidents of nuclear power plants. This method is carried out after the Fukushima accident. In this research, the postulations beyond design basis accidentsof PWR AP - 1000 would be taken, and simulated at West Bangka sample site. The

  17. New algorithm to detect modules in a fault tree for a PSA

    International Nuclear Information System (INIS)

    Jung, Woo Sik

    2015-01-01

    A module or independent subtree is a part of a fault tree whose child gates or basic events are not repeated in the remaining part of the fault tree. Modules are necessarily employed in order to reduce the computational costs of fault tree quantification. This paper presents a new linear time algorithm to detect modules of large fault trees. The size of cut sets can be substantially reduced by replacing independent subtrees in a fault tree with super-components. Chatterjee and Birnbaum developed properties of modules, and demonstrated their use in the fault tree analysis. Locks expanded the concept of modules to non-coherent fault trees. Independent subtrees were manually identified while coding a fault tree for computer analysis. However, nowadays, the independent subtrees are automatically identified by the fault tree solver. A Dutuit and Rauzy (DR) algorithm to detect modules of a fault tree for coherent or non-coherent fault tree was proposed in 1996. It has been well known that this algorithm quickly detects modules since it is a linear time algorithm. The new algorithm minimizes computational memory and quickly detects modules. Furthermore, it can be easily implemented into industry fault tree solvers that are based on traditional Boolean algebra, binary decision diagrams (BDDs), or Zero-suppressed BDDs. The new algorithm employs only two scalar variables in Eqs. to that are volatile information. After finishing the traversal and module detection of each node, the volatile information is destroyed. Thus, the new algorithm does not employ any other additional computational memory and operations. It is recommended that this method be implemented into fault tree solvers for efficient probabilistic safety assessment (PSA) of nuclear power plants

  18. New algorithm to detect modules in a fault tree for a PSA

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Woo Sik [Sejong University, Seoul (Korea, Republic of)

    2015-05-15

    A module or independent subtree is a part of a fault tree whose child gates or basic events are not repeated in the remaining part of the fault tree. Modules are necessarily employed in order to reduce the computational costs of fault tree quantification. This paper presents a new linear time algorithm to detect modules of large fault trees. The size of cut sets can be substantially reduced by replacing independent subtrees in a fault tree with super-components. Chatterjee and Birnbaum developed properties of modules, and demonstrated their use in the fault tree analysis. Locks expanded the concept of modules to non-coherent fault trees. Independent subtrees were manually identified while coding a fault tree for computer analysis. However, nowadays, the independent subtrees are automatically identified by the fault tree solver. A Dutuit and Rauzy (DR) algorithm to detect modules of a fault tree for coherent or non-coherent fault tree was proposed in 1996. It has been well known that this algorithm quickly detects modules since it is a linear time algorithm. The new algorithm minimizes computational memory and quickly detects modules. Furthermore, it can be easily implemented into industry fault tree solvers that are based on traditional Boolean algebra, binary decision diagrams (BDDs), or Zero-suppressed BDDs. The new algorithm employs only two scalar variables in Eqs. to that are volatile information. After finishing the traversal and module detection of each node, the volatile information is destroyed. Thus, the new algorithm does not employ any other additional computational memory and operations. It is recommended that this method be implemented into fault tree solvers for efficient probabilistic safety assessment (PSA) of nuclear power plants.

  19. Cost implications of PSA screening differ by age.

    Science.gov (United States)

    Rao, Karthik; Liang, Stella; Cardamone, Michael; Joshu, Corinne E; Marmen, Kyle; Bhavsar, Nrupen; Nelson, William G; Ballentine Carter, H; Albert, Michael C; Platz, Elizabeth A; Pollack, Craig E

    2018-05-09

    Multiple guidelines seek to alter rates of prostate-specific antigen (PSA)-based prostate cancer screening. The costs borne by payers associated with PSA-based screening for men of different age groups-including the costs of screening and subsequent diagnosis, treatment, and adverse events-remain uncertain. We sought to develop a model of PSA costs that could be used by payers and health care systems to inform cost considerations under a range of different scenarios. We determined the prevalence of PSA screening among men aged 50 and higher using 2013-2014 data from a large, multispecialty group, obtained reimbursed costs associated with screening, diagnosis, and treatment from a commercial health plan, and identified transition probabilities for biopsy, diagnosis, treatment, and complications from the literature to generate a cost model. We estimated annual total costs for groups of men ages 50-54, 55-69, and 70+ years, and varied annual prostate cancer screening prevalence in each group from 5 to 50% and tested hypothetical examples of different test characteristics (e.g., true/false positive rate). Under the baseline screening patterns, costs of the PSA screening represented 10.1% of the total costs; costs of biopsies and associated complications were 23.3% of total costs; and, although only 0.3% of all screen eligible patients were treated, they accounted for 66.7% of total costs. For each 5-percentage point decrease in PSA screening among men aged 70 and older for a single calendar year, total costs associated with prostate cancer screening decreased by 13.8%. For each 5-percentage point decrease in PSA screening among men 50-54 and 55-69 years old, costs were 2.3% and 7.3% lower respectively. With constrained financial resources and with national pressure to decrease use of clinically unnecessary PSA-based prostate cancer screening, there is an opportunity for cost savings, especially by focusing on the downstream costs disproportionately associated with

  20. Multi keno-VAX a modified version of the reactor computer code Multi keno-2

    Energy Technology Data Exchange (ETDEWEB)

    Imam, M [National center for nuclear safety and radiation control, atomic energy authority, Cairo, (Egypt)

    1995-10-01

    The reactor computer code Multi keno-2 is developed in Japan from the original Monte Carlo Keno-IV. By applications of this code on some real problems, fatal errors were detected. These errors are related to the restart option in the code. The restart option is essential for solving time-consuming problems on mini-computer like VAX-6320. These errors were corrected and other modifications were carried out in the code. Because of these modifications new input data description was written for the code. Thus a new VAX/VMS version for the program was developed which is also adaptable for mini-mainframes. This new developed program, called Multi keno-VAX is accepted in the Nea-IAEA data bank and is added to its international computer codes library. 1 fig.

  1. Multi keno-VAX a modified version of the reactor computer code Multi keno-2

    International Nuclear Information System (INIS)

    Imam, M.

    1995-01-01

    The reactor computer code Multi keno-2 is developed in Japan from the original Monte Carlo Keno-IV. By applications of this code on some real problems, fatal errors were detected. These errors are related to the restart option in the code. The restart option is essential for solving time-consuming problems on mini-computer like VAX-6320. These errors were corrected and other modifications were carried out in the code. Because of these modifications new input data description was written for the code. Thus a new VAX/VMS version for the program was developed which is also adaptable for mini-mainframes. This new developed program, called Multi keno-VAX is accepted in the Nea-IAEA data bank and is added to its international computer codes library. 1 fig

  2. Applicability of PSA Issues for Risk Assessment during Optimisation of In-Service Inspection

    International Nuclear Information System (INIS)

    Kolykhanov, V.; Skalozubov, V.; Kovrigkin, Y.

    2006-01-01

    The current codes determining periodicity of in-service inspection of the NPP equipment have been formed using deterministic approaches and have an unnecessary degree of conservatism. A perspective direction of perfection of normative base is decision making on a basis of risk-informed methodologies. It allows to increase safety of NPP equipment's operation and to optimise programs on inspection of the equipment subject to limited resources by focusing efforts on the most safety significant elements of the equipment. It is internationally accepted that methodology of the probabilistic safety analysis (PSA) is the most universal and comprehensive tool focused on the general assessment of safety of NPP as a whole. By now, PSA Level 1 is fulfilled for all pilot units of the Ukrainian NPPs that is a valuable result, which should be taken into account at an assessment of reliability of the equipment. However, specificity of PSA methodology should be taken into account at the decision of the particular tasks aimed at optimisation of maintenance of the equipment within individual systems. The estimation of the contribution to core damage frequency (CDF) is a PSA issue usually used to assess the significance of consequences of failure of a system/equipment during risk-informed decision-making. This work shows that above factor is only a part of assessment of the significance of consequences as core damage can be expressed in different amount of the damaged fuel elements and, hence, severity of consequences. Besides CDF is directly affected only by active elements which failure can be an initiating event. PSA methodology uses averaged reliability factors of the equipment for all possible operating modes occurring at transitive accident process. Here, there are limited opportunities to account impact of periodicity of maintenance of the equipment on reliability and to predict impact of change of the inspection program. PSA methodology does not allow taking into account

  3. PSA as a tool for decision making

    Energy Technology Data Exchange (ETDEWEB)

    Niehaus, F; Lederman, L

    1986-05-01

    The question on ''How safe is safe enough'' is being responded presently by deterministic criteria. Probabilistic criteria in support to more rational and less emotional decisions in regulatory and licensing issues, rationalization of resource allocation and research prioritization, among others, have a potential which is only marginally being explored. This paper discussed PSA limitations and proposes three areas for the use of PSA in decision making, namely: preventing accidents, mitigating accidents, and defining regulatory requirements. Current activities of the International Atomic Energy Agency in these areas are mentioned. PSA studies depict clearly the uncertainties and this is viewed as a positive aspect, which is unique to the use of probabilistic methods.

  4. Elevation of PSA after prostate radiotherapy: Rebound or biochemical recurrence?

    International Nuclear Information System (INIS)

    Toledano, A.; Kanoui, A.; Chiche, R.; Lamallem, H.; Beley, S.; Thibault, F.; Sebe, P.

    2008-01-01

    The fact that external beam radiotherapy and brachytherapy are now considered to be curative techniques has led to major review of the modalities of follow-up after radiotherapy for prostate cancer. The problem concerns both the diagnosis of recurrence, rapidly announced by elevation of prostatic-specific antigen (PSA), usually at a subclinical stage, and the validity of criteria of biochemical recurrence to allow comparison of various study. Physicians involved in follow-up should be aware of the potential of bounce in PSA follow-up after external beam radiotherapy or brachytherapy. The PSA bounce phenomenon was defined by a rise of PSA values (+ 0.1 -0.8 ng/ml) with a subsequent fall. Biochemical failure after external beam radiotherapy or brachytherapy (with or without hormonotherapy) was defined by Phoenix criteria by a rise of 2 ng/ml above an initial PSA nadir. This definition was more correlated to PSA bounce phenomenon. (authors)

  5. Phenomenological optical potentials and optical model computer codes

    International Nuclear Information System (INIS)

    Prince, A.

    1980-01-01

    An introduction to the Optical Model is presented. Starting with the purpose and nature of the physical problems to be analyzed, a general formulation and the various phenomenological methods of solution are discussed. This includes the calculation of observables based on assumed potentials such as local and non-local and their forms, e.g. Woods-Saxon, folded model etc. Also discussed are the various calculational methods and model codes employed to describe nuclear reactions in the spherical and deformed regions (e.g. coupled-channel analysis). An examination of the numerical solutions and minimization techniques associated with the various codes, is briefly touched upon. Several computer programs are described for carrying out the calculations. The preparation of input, (formats and options), determination of model parameters and analysis of output are described. The class is given a series of problems to carry out using the available computer. Interpretation and evaluation of the samples includes the effect of varying parameters, and comparison of calculations with the experimental data. Also included is an intercomparison of the results from the various model codes, along with their advantages and limitations. (author)

  6. RADTRAN II: revised computer code to analyze transportation of radioactive material

    International Nuclear Information System (INIS)

    Taylor, J.M.; Daniel, S.L.

    1982-10-01

    A revised and updated version of the RADTRAN computer code is presented. This code has the capability to predict the radiological impacts associated with specific schemes of radioactive material shipments and mode specific transport variables

  7. FIRAC: a computer code to predict fire-accident effects in nuclear facilities

    International Nuclear Information System (INIS)

    Bolstad, J.W.; Krause, F.R.; Tang, P.K.; Andrae, R.W.; Martin, R.A.; Gregory, W.S.

    1983-01-01

    FIRAC is a medium-sized computer code designed to predict fire-induced flows, temperatures, and material transport within the ventilating systems and other airflow pathways in nuclear-related facilities. The code is designed to analyze the behavior of interconnected networks of rooms and typical ventilation system components. This code is one in a family of computer codes that is designed to provide improved methods of safety analysis for the nuclear industry. The structure of this code closely follows that of the previously developed TVENT and EVENT codes. Because a lumped-parameter formulation is used, this code is particularly suitable for calculating the effects of fires in the far field (that is, in regions removed from the fire compartment), where the fire may be represented parametrically. However, a fire compartment model to simulate conditions in the enclosure is included. This model provides transport source terms to the ventilation system that can affect its operation and in turn affect the fire

  8. Computer codes for simulating atomic-displacement cascades in solids subject to irradiation

    International Nuclear Information System (INIS)

    Asaoka, Takumi; Taji, Yukichi; Tsutsui, Tsuneo; Nakagawa, Masayuki; Nishida, Takahiko

    1979-03-01

    In order to study atomic displacement cascades originating from primary knock-on atoms in solids subject to incident radiation, the simulation code CASCADE/CLUSTER is adapted for use on FACOM/230-75 computer system. In addition, the code is modified so as to plot the defect patterns in crystalline solids. As other simulation code of the cascade process, MARLOWE is also available for use on the FACOM system. To deal with the thermal annealing of point defects produced in the cascade process, the code DAIQUIRI developed originally for body-centered cubic crystals is modified to be applicable also for face-centered cubic lattices. By combining CASCADE/CLUSTER and DAIQUIRI, we then prepared a computer code system CASCSRB to deal with heavy irradiation or saturation damage state of solids at normal temperature. Furthermore, a code system for the simulation of heavy irradiations CASCMARL is available, in which MARLOWE code is substituted for CASCADE in the CASCSRB system. (author)

  9. Theoretical calculation possibilities of the computer code HAMMER

    International Nuclear Information System (INIS)

    Onusic Junior, J.

    1978-06-01

    With the aim to know the theoretical calculation possibilities of the computer code HAMMER, developed at Savanah River Laboratory, a analysis of the crytical cells assembly of the kind utilized in PWR reactors is made. (L.F.S.) [pt

  10. Rate of PSA rise predicts metastatic versus local recurrence after definitive radiotherapy

    International Nuclear Information System (INIS)

    Sartor, C.I.; Strawderman, M.H.; Lin, X.; Kish, K.E.; McLaughlin, P.W.; Lichter, A.S.; Sandler, H.S.

    1995-01-01

    Objective: A rising PSA following treatment for adenocarcinoma of the prostate indicates eventual clinical failure, but the rate of rise can be quite different from patient to patient, as can the pattern of clinical failure. We sought to determine whether the rate of PSA rise could differentiate future local vs. metastatic failure. Materials and Methods: PSA values from our series of 671 patients treated between 1987 and 1994 with 3-D conformal radiotherapy for localized adenocarcinoma were analyzed. Patients who had a pre-treatment PSA and >4 post-treatment PSA values available, had received no hormonal therapy, and had information detailing clinical outcome were used in this analysis. First site of failure was determined by abnormal DRE or biopsy, abnormal bone scan or radiographic evidence of metastasis as directed by clinical symptoms or follow-up clinical exam. Each patient's PSA pattern was defined by the function PSA(t)=C 1 e - a 1 (t) + C 2 e a 2 (t) where -a 1 relates to the rate of decline and a 2 to the rate of rise, if any. Univariate analysis was used to determine the correlation between initial PSA or rising PSA and clinical failure. Adjacent category logistic regression analysis was used to analyze the rate of rise and pattern of clinical failure. Results: 671 patients were reviewed; 401 patients met the requirements and 2667 PSA values were analyzed. We confirmed the finding of others that pre-treatment PSA is a prognostic indicator: patients presenting with PSA 3-20ng/ml had a relative risk of 9 (p=0.03) and PSA>20ng/ml had a RR of 26 (p=0.002) for clinical failure when compared to presenting PSA 2 >1.5/year predicted metastatic as opposed to local failure when compared to PSA rise with a 2 between 0.5-1.5/yr or 1.5 log(ng/ml)/year vs. 0.5-1.5 log(ng/ml)/yr or <0.5 log(ng/ml)/yr. Conclusions: The rate of rise of PSA following definitive radiotherapy can predict clinical failure patterns, with a rapidly rising PSA indicating metastatic as opposed to

  11. Use of computer codes to improve nuclear power plant operation

    International Nuclear Information System (INIS)

    Misak, J.; Polak, V.; Filo, J.; Gatas, J.

    1985-01-01

    For safety and economic reasons, the scope for carrying out experiments on operational nuclear power plants (NPPs) is very limited and any changes in technical equipment and operating parameters or conditions have to be supported by theoretical calculations. In the Nuclear Power Plant Scientific Research Institute (NIIAEhS), computer codes are systematically used to analyse actual operating events, assess safety aspects of changes in equipment and operating conditions, optimize the conditions, preparation and analysis of NPP startup trials and review and amend operating instructions. In addition, calculation codes are gradually being introduced into power plant computer systems to perform real time processing of the parameters being measured. The paper describes a number of specific examples of the use of calculation codes for the thermohydraulic analysis of operating and accident conditions aimed at improving the operation of WWER-440 units at the Jaslovske Bohunice V-1 and V-2 nuclear power plants. These examples confirm that computer calculations are an effective way of solving operating problems and of further increasing the level of safety and economic efficiency of NPP operation. (author)

  12. Ascertaining the international state of the art of PSA methodology

    International Nuclear Information System (INIS)

    Linden, J. von

    1998-01-01

    Plant-specific PSAs, to be performed within the framework of the Periodic Safety Review of German Nuclear Power Plants require further development of the methodology. For that purpose foreign PSA-guidelines and PSA-reviewes as well as relevant literature are examined and appropriate insights are adopted within task A.2 of project SR 2096. The main goal of these activities is to achieve a comparison of the state of the art of PSA-methodologies applied abroad and in Germany. The German state of the art refers to the extent as is documented in the German PSA Guide (Leitfaden Probabilistische Sicherheitsanalyse /PSUe97/) which has to be used for the Periodic Safety Review of German Nuclear Power Plants. The structure for the evaluation is based on the working steps of a PSA. In total, according to the objectives of the Periodic Safety Review the German approach for plant-specific PSAs based on the German PSA Guide is conform to the state of the art abroad. Identified deviations in some details are evaluated reflecting the view of GRS. Particular aspects resulting from the evaluation should be considered for further development of the German PSA Guide. (orig.) [de

  13. A computer code for fault tree calculations: PATREC

    International Nuclear Information System (INIS)

    Blin, A.; Carnino, A.; Koen, B.V.; Duchemin, B.; Lanore, J.M.; Kalli, H.

    1978-01-01

    A computer code for evaluating the reliability of complex system by fault tree is described in this paper. It uses pattern recognition approach and programming techniques from IBM PL1 language. It can take account of many of the present day problems: multi-dependencies treatment, dispersion in the reliability data parameters, influence of common mode failures. The code is running currently since two years now in Commissariat a l'Energie Atomique Saclay center and shall be used in a future extension for automatic fault trees construction

  14. Development of a tracer transport option for the NAPSAC fracture network computer code

    International Nuclear Information System (INIS)

    Herbert, A.W.

    1990-06-01

    The Napsac computer code predicts groundwater flow through fractured rock using a direct fracture network approach. This paper describes the development of a tracer transport algorithm for the NAPSAC code. A very efficient particle-following approach is used enabling tracer transport to be predicted through large fracture networks. The new algorithm is tested against three test examples. These demonstrations confirm the accuracy of the code for simple networks, where there is an analytical solution to the transport problem, and illustrates the use of the computer code on a more realistic problem. (author)

  15. Age-Specific Cutoff Value for the Application of Percent Free Prostate-Specific Antigen (PSA) in Chinese Men with Serum PSA Levels of 4.0–10.0 ng/ml

    Science.gov (United States)

    Xie, Liping; He, Dalin; Zhou, Liqun; Xu, Chuanliang; Gao, Xu; Ren, Shancheng; Wang, Fubo; Ma, Lulin; Wei, Qiang; Yin, Changjun; Tian, Ye; Sun, Zhongquan; Fu, Qiang; Ding, Qiang; Zheng, Junhua; Ye, Zhangqun; Ye, Dingwei; Xu, Danfeng; Hou, Jianquan; Xu, Kexin; Yuan, Jianlin; Gao, Xin; Liu, Chunxiao; Pan, Tiejun; Sun, Yinghao

    2015-01-01

    Objective The influence of age on the performance of percent free prostate-specific antigen (%fPSA) in diagnosing prostate cancer (PCa) in East Asians is controversial. We tested the diagnostic performance of %fPSA in a multi-center biopsy cohort in China and identified the proper age-specific cutoff values to avoid unnecessary biopsies. Methods Consecutive patients with a prostate-specific antigen (PSA) level of 4.0–10.0 ng/ml or 10.1–20.0 ng/ml who underwent transrectal ultrasound-guided or transperineal prostate biopsy were enrolled from 22 Chinese medical centers from Jan 1, 2010 to Dec 31, 2013. The diagnostic accuracy of PSA and %fPSA was determined using the area under the receiver operating characteristic (ROC) curve (AUC). Age-specific cutoff values were calculated using ROC curve analysis. Results The median %fPSA was much lower in younger patients compared with older patients with a PSA level of 4.0–10.0 ng/ml or 10.1–20.0 ng/ml. The AUC of %fPSA was higher than PSA only in older patients. In patients aged 50 to 59 years, %fPSA failed to improve the diagnosis compared with PSA in these two PSA ranges. Age-specific cutoff values were 24%, 27% and 32% for patients aged 60–69, 70–79 and ≥80 years, respectively, to reduce unnecessary biopsies in men with PSA levels of 4.0–10.0 ng/ml to detect 90% of all PCa. Conclusions The effectiveness of %fPSA is correlated with age in the Chinese population. Age-specific cutoff values would help avoid unnecessary biopsies in the Chinese population. PMID:26091007

  16. FRAP-T1: a computer code for the transient analysis of oxide fuel rods

    International Nuclear Information System (INIS)

    Dearien, J.A.; Miller, R.L.; Hobbins, R.R.; Siefken, L.J.; Baston, V.F.; Coleman, D.R.

    1977-02-01

    FRAP-T is a FORTRAN IV computer code which can be used to solve for the transient response of a light water reactor (LWR) fuel rod during accident transients such as loss-of-coolant accident (LOCA) or a power-cooling-mismatch (PCM). The coupled effects of mechanical, thermal, internal gas, and material property response on the behavior of the fuel rod are considered. FRAP-T is a modular code with each major computational model isolated within the code and coupled to the main code by subroutine calls and data transfer through argument lists. FRAP-T is coupled to a materials properties subcode (MATPRO) which is used to provide gas, fuel, and cladding properties to the FRAP-T computational subcodes. No material properties need be supplied by the code user. The needed water properties are stored in tables built into the code. Critical heat flux (CHF) and heat transfer correlations for a wide range of coolant conditions are contained in modular subroutines. FRAP-T has been evaluated by making extensive comparisons between predictions of the code and experimental data. Comparison of predicted and experimental results are presented for a range of FRAP-T calculated parameters. The code is presently programmed and running on an IBM-360/75 and a CDC 7600 computer

  17. A source term and risk calculations using level 2+PSA methodology

    International Nuclear Information System (INIS)

    Park, S. I.; Jea, M. S.; Jeon, K. D.

    2002-01-01

    The scope of Level 2+ PSA includes the assessment of dose risk which is associated with the exposures of the radioactive nuclides escaping from nuclear power plants during severe accidents. The establishment of data base for the exposure dose in Korea nuclear power plants may contribute to preparing the accident management programs and periodic safety reviews. In this study the ORIGEN, MELCOR and MACCS code were employed to produce a integrated framework to assess the radiation source term risk. The framework was applied to a reference plant. Using IPE results, the dose rate for the reference plant was calculated quantitatively

  18. External Events PSA for the Paks NPP

    International Nuclear Information System (INIS)

    Bareith, Attila; Karsa, Zoltan; Siklossy, Tamas; Vida, Zoltan

    2014-01-01

    Initially, probabilistic safety assessment of external events was limited to the analysis of earthquakes for the Paks Nuclear Power Plant in Hungary. The level 1 seismic PSA was completed in 2002 showing a significant contribution of seismic failures to core damage risk. Although other external events of natural origin had previously been screened out from detailed plant PSA mostly on the basis of event frequencies, a review of recent experience on extreme weather phenomena made during the periodic safety review of the plant led to the initiation of PSA for external events other than earthquakes in 2009. In the meantime, the accident of the Fukushima Dai-ichi Nuclear Power Plant confirmed further the importance of such an analysis. The external event PSA for the Paks plant followed the commonly known steps: selection and screening of external hazards, hazard assessment for screened-in external events, analysis of plant response and fragility, PSA model development, and risk quantification and interpretation of results. As a result of event selection and screening the following weather related external hazards were subject to detailed analysis: extreme wind, extreme rainfall (precipitation), extreme snow, extremely high and extremely low temperatures, lightning, frost and ice formation. The analysis proved to be a significant challenge due to scarcity of data, lack of knowledge, as well as limitations of existing PSA methodologies. This paper presents an overview of the external events PSA performed for the Paks NPP. Important methodological aspects are summarised. Key analysis findings and unresolved issues that need further elaboration are highlighted. Development of external events PSA for the Paks NPP was completed by the end of 2012. The analysis followed the commonly known steps: selection and screening of external hazards, hazard assessment for screened-in external events, analysis of plant response and fragility, PSA model development, and risk

  19. NEWSPEC: A computer code to unfold neutron spectra from Bonner sphere data

    International Nuclear Information System (INIS)

    Lemley, E.C.; West, L.

    1996-01-01

    A new computer code, NEWSPEC, is in development at the University of Arkansas. The NEWSPEC code allows a user to unfold, fold, rebin, display, and manipulate neutron spectra as applied to Bonner sphere measurements. The SPUNIT unfolding algorithm, a new rebinning algorithm, and the graphical capabilities of Microsoft (MS) Windows and MS Excel are utilized to perform these operations. The computer platform for NEWSPEC is a personal computer (PC) running MS Windows 3.x or Win95, while the code is written in MS Visual Basic (VB) and MS VB for Applications (VBA) under Excel. One of the most useful attributes of the NEWSPEC software is the link to Excel allowing additional manipulation of program output or creation of program input

  20. Seminal plasma PSA in spinal cord injured men

    DEFF Research Database (Denmark)

    Brasso, K; Sønksen, J; Sommer, P

    1998-01-01

    The aim of the study was to evaluate the impact of spinal cord injury on seminal plasma PSA concentration.......The aim of the study was to evaluate the impact of spinal cord injury on seminal plasma PSA concentration....

  1. PSA modeling of long-term accident sequences

    International Nuclear Information System (INIS)

    Georgescu, Gabriel; Corenwinder, Francois; Lanore, Jeanne-Marie

    2014-01-01

    In the context of the extension of PSA scope to include external hazards, in France, both operator (EDF) and IRSN work for the improvement of methods to better take into account in the PSA the accident sequences induced by initiators which affect a whole site containing several nuclear units (reactors, fuel pools,...). These methodological improvements represent an essential prerequisite for the development of external hazards PSA. However, it has to be noted that in French PSA, even before Fukushima, long term accident sequences were taken into account: many insight were therefore used, as complementary information, to enhance the safety level of the plants. IRSN proposed an external events PSA development program. One of the first steps of the program is the development of methods to model in the PSA the long term accident sequences, based on the experience gained. At short term IRSN intends to enhance the modeling of the 'long term' accident sequences induced by the loss of the heat sink or/and the loss of external power supply. The experience gained by IRSN and EDF from the development of several probabilistic studies treating long term accident sequences shows that the simple extension of the mission time of the mitigation systems from 24 hours to longer times is not sufficient to realistically quantify the risk and to obtain a correct ranking of the risk contributions and that treatment of recoveries is also necessary. IRSN intends to develop a generic study which can be used as a general methodology for the assessment of the long term accident sequences, mainly generated by external hazards and their combinations. This first attempt to develop this generic study allowed identifying some aspects, which may be hazard (or combinations of hazards) or related to initial boundary conditions, which should be taken into account for further developments. (authors)

  2. KC-A Kinectic computer code for investigation of parametric plasma instabilities

    International Nuclear Information System (INIS)

    Olshansky, V.

    1995-07-01

    In the frame of a joint research program of the Institute of Plasma Physics of the NationaI Science Center 'Kharkov Institute of Physics and Technology' (Kh IPT), Ukraine, and the plasma physics group of the Austrian Research Center Seibersdorf (FZS) a kinetic computer code with the acronym KC for investigation of paramarametric plasma instabilities has been implemented at the computer facilities of FZS as a starting point for further research in this field. This code based on a macroparticle technique is appropriate for studying the evolution of instabilities in a turbulent plasma including saturation. The results can be of interest for heating of tokamaks of the next generation, i.g. ITER. The present report describes the underlying physical models and numerical methods as well as the code structure and how to use the code as a reference of forthcoming joint papers. (author)

  3. Computer codes for problems of isotope and radiation research

    International Nuclear Information System (INIS)

    Remer, M.

    1986-12-01

    A survey is given of computer codes for problems in isotope and radiation research. Altogether 44 codes are described as titles with abstracts. 17 of them are in the INIS scope and are processed individually. The subjects are indicated in the chapter headings: 1) analysis of tracer experiments, 2) spectrum calculations, 3) calculations of ion and electron trajectories, 4) evaluation of gamma irradiation plants, and 5) general software

  4. Sample test cases using the environmental computer code NECTAR

    International Nuclear Information System (INIS)

    Ponting, A.C.

    1984-06-01

    This note demonstrates a few of the many different ways in which the environmental computer code NECTAR may be used. Four sample test cases are presented and described to show how NECTAR input data are structured. Edited output is also presented to illustrate the format of the results. Two test cases demonstrate how NECTAR may be used to study radio-isotopes not explicitly included in the code. (U.K.)

  5. Standardization of computer programs - basis of the Czechoslovak library of nuclear codes

    International Nuclear Information System (INIS)

    Gregor, M.

    1987-01-01

    A standardized form of computer code documentation has been established in the CSSR in the field of reactor safety. Structure and content of the documentation are described and codes already subject to this process are mentioned. The formation of a Czechoslovak nuclear code library and facilitated discussion of safety reports containing results of standardized codes are aimed at

  6. PSA in licensing, safety reviews and design as applied in Germany

    International Nuclear Information System (INIS)

    Berg, H.P.; Goertz, R.; Schott, H.; Wendling, R.D.

    1994-01-01

    In this paper, two topics - the application of PSA in the regulatory process and the effort to improve PSA methods and models - are addressed. From the regulators' point of view, the most important application of PSA in Germany is presently within the safety reviews of nuclear power plants in operation. The current status of regulatory guidance which shall be provided to establish a uniform procedure for a periodic safety review is described with special emphasis on the role of PSA. An important goal is to have all plant-specific PSAs comparable as far as possible. Guidance for PSA review is under development likewise. Furthermore, the application of PSA in licensing of nuclear power plants is addressed as well as its use in the design process of future pressurized water reactors. The development of models and methods to be applied in PSA has been and will be supported by a number of studies and investigations. An overview of the main issues of these investigations is provided. A specific task was the elaboration of a proposal for incorporating fire events into the PSA. The status of these efforts is outlined. (author). 7 refs, 3 figs, 2 tabs

  7. Quality assurance aspects of the computer code CODAR2

    International Nuclear Information System (INIS)

    Maul, P.R.

    1986-03-01

    The computer code CODAR2 was developed originally for use in connection with the Sizewell Public Inquiry to evaluate the radiological impact of routine discharges to the sea from the proposed PWR. It has subsequently bee used to evaluate discharges from Heysham 2. The code was frozen in September 1983, and this note gives details of its verification, validation and evaluation. Areas where either improved modelling methods or more up-to-date information relevant to CODAR2 data bases have subsequently become available are indicated; these will be incorporated in any future versions of the code. (author)

  8. A restructuring of TF package for MIDAS computer code

    International Nuclear Information System (INIS)

    Park, S. H.; Song, Y. M.; Kim, D. H.

    2002-01-01

    TF package which defines some interpolation and extrapolation condition through user defined table has been restructured in MIDAS computer code. To do this, data transferring methods of current MELCOR code are modified and adopted into TF package. The data structure of the current MELCOR code using FORTRAN77 causes a difficult grasping of the meaning of the variables as well as waste of memory. New features of FORTRAN90 make it possible to allocate the storage dynamically and to use the user-defined data type, which lead to an efficient memory treatment and an easy understanding of the code. Restructuring of TF package addressed in this paper does module development and subroutine modification, and treats MELGEN which is making restart file as well as MELCOR which is processing calculation. The validation has been done by comparing the results of the modified code with those from the existing code, and it is confirmed that the results are the same. It hints that the similar approach could be extended to the entire code package. It is expected that code restructuring will accelerate the code domestication thanks to direct understanding of each variable and easy implementation of modified or newly developed models

  9. FLAME: A finite element computer code for contaminant transport n variably-saturated media

    International Nuclear Information System (INIS)

    Baca, R.G.; Magnuson, S.O.

    1992-06-01

    A numerical model was developed for use in performance assessment studies at the INEL. The numerical model referred to as the FLAME computer code, is designed to simulate subsurface contaminant transport in a variably-saturated media. The code can be applied to model two-dimensional contaminant transport in an and site vadose zone or in an unconfined aquifer. In addition, the code has the capability to describe transport processes in a porous media with discrete fractures. This report presents the following: description of the conceptual framework and mathematical theory, derivations of the finite element techniques and algorithms, computational examples that illustrate the capability of the code, and input instructions for the general use of the code. The development of the FLAME computer code is aimed at providing environmental scientists at the INEL with a predictive tool for the subsurface water pathway. This numerical model is expected to be widely used in performance assessments for: (1) the Remedial Investigation/Feasibility Study process and (2) compliance studies required by the US Department of energy Order 5820.2A

  10. FLAME: A finite element computer code for contaminant transport n variably-saturated media

    Energy Technology Data Exchange (ETDEWEB)

    Baca, R.G.; Magnuson, S.O.

    1992-06-01

    A numerical model was developed for use in performance assessment studies at the INEL. The numerical model referred to as the FLAME computer code, is designed to simulate subsurface contaminant transport in a variably-saturated media. The code can be applied to model two-dimensional contaminant transport in an and site vadose zone or in an unconfined aquifer. In addition, the code has the capability to describe transport processes in a porous media with discrete fractures. This report presents the following: description of the conceptual framework and mathematical theory, derivations of the finite element techniques and algorithms, computational examples that illustrate the capability of the code, and input instructions for the general use of the code. The development of the FLAME computer code is aimed at providing environmental scientists at the INEL with a predictive tool for the subsurface water pathway. This numerical model is expected to be widely used in performance assessments for: (1) the Remedial Investigation/Feasibility Study process and (2) compliance studies required by the US Department of energy Order 5820.2A.

  11. PSA as a tool for decision making

    International Nuclear Information System (INIS)

    Niehaus, F.; Lederman, L.

    1986-01-01

    The question on ''How safe is safe enough'' is being responded presently by deterministic criteria. Probabilistic criteria in support to more rational and less emotional decisions in regulatory and licensing issues, rationalization of resource allocation and research prioritization, among others, have a potential which is only marginally being explored. This paper discussed PSA limitations and proposes three areas for the use of PSA in decision making, namely: preventing accidents, mitigating accidents, and defining regulatory requirements. Current activities of the International Atomic Energy Agency in these areas are mentioned. PSA studies depict clearly the uncertainties and this is viewed as a positive aspect, which is unique to the use of probabilistic methods. (orig.)

  12. Atmospheric dispersion of radioactive releases: Computer code DIASPORA

    International Nuclear Information System (INIS)

    Synodinou, B.M.; Bartzis, J.M.

    1982-05-01

    The computer code DIASPORA is presented. Air and ground concentrations of an airborne radioactive material released from an elevated continuous point source are calculated using Gaussian plume models. Dry and wet deposition as well as plume rise effects are taken into consideration. (author)

  13. Validation and uncertainty analysis of the Athlet thermal-hydraulic computer code

    International Nuclear Information System (INIS)

    Glaeser, H.

    1995-01-01

    The computer code ATHLET is being developed by GRS as an advanced best-estimate code for the simulation of breaks and transients in Pressurized Water Reactor (PWRs) and Boiling Water Reactor (BWRs) including beyond design basis accidents. A systematic validation of ATHLET is based on a well balanced set of integral and separate effects tests emphasizing the German combined Emergency Core Cooling (ECC) injection system. When using best estimate codes for predictions of reactor plant states during assumed accidents, qualification of the uncertainty in these calculations is highly desirable. A method for uncertainty and sensitivity evaluation has been developed by GRS where the computational effort is independent of the number of uncertain parameters. (author)

  14. [Use of prostatic specific antigen in primary care (PSA)].

    Science.gov (United States)

    Panach-Navarrete, J; Gironés-Montagud, A; Sánchez-Cano, E; Doménech-Pérez, C; Martínez-Jabaloyas, J M

    2017-04-01

    In the literature it is shown that the use of PSA is occasionally wrong, by requesting this marker in very young or very old men, and repeated measurements in short periods of time. The main objective of this study was to describe the use of PSA in daily practice by primary care physicians in our area, dealing with aspects such as the importance of patient age, the value in the screening for prostate cancer, or the subjective beliefs about its usefulness. A secondary objective was the comparison of use, and beliefs among doctors who claim to know PSA well, and those who do not. A descriptive and comparative study was conducted using questionnaires that were handed to primary care doctors in all health centres in our area. A descriptive analysis was performed and response rates among doctors who thought they had enough information about PSA, and those who did not, were compared using the Chi-squared test. A total of 103 questionnaires were received from the physicians, with 83.5% claiming to have sufficient knowledge about the PSA. The professionals in this latter group request PSA at an earlier age (P=.029), with a higher frequency (P=.011) and have more doubts about its usefulness (P=.009) than those with less knowledge. Almost half (49.5%) said they request less than 50 determinations per year, and 33% between 50 and 100. More than half (53.4%) of doctors would not request the first PSA on a patient until their 50s, and up to 49% request it up to 80 years. The true value of PSA has been established many times by 64.1% of requesters, and 29.1% believe it is unhelpful in the diagnosis of cancer. In our study, 64% of primary care physicians have considered the true value of the PSA several times, and 29% believe it to be of little use in the diagnosis of prostate cancer. In addition, some data suggest it has limited use due to the fact that 50% made less than 50 PSA requests per years, and 28% of the professionals would never request it on a male without urinary

  15. LMFBR models for the ORIGEN2 computer code

    International Nuclear Information System (INIS)

    Croff, A.G.; McAdoo, J.W.; Bjerke, M.A.

    1981-10-01

    Reactor physics calculations have led to the development of nine liquid-metal fast breeder reactor (LMFBR) models for the ORIGEN2 computer code. Four of the models are based on the U-Pu fuel cycle, two are based on the Th-U-Pu fuel cycle, and three are based on the Th- 238 U fuel cycle. The reactor models are based on cross sections taken directly from the reactor physics codes. Descriptions of the reactor models as well as values for the ORIGEN2 flux parameters THERM, RES, and FAST are given

  16. Benchmarking severe accident computer codes for heavy water reactor applications

    Energy Technology Data Exchange (ETDEWEB)

    Choi, J.H. [International Atomic Energy Agency, Vienna (Austria)

    2010-07-01

    Consideration of severe accidents at a nuclear power plant (NPP) is an essential component of the defence in depth approach used in nuclear safety. Severe accident analysis involves very complex physical phenomena that occur sequentially during various stages of accident progression. Computer codes are essential tools for understanding how the reactor and its containment might respond under severe accident conditions. International cooperative research programmes are established by the IAEA in areas that are of common interest to a number of Member States. These co-operative efforts are carried out through coordinated research projects (CRPs), typically 3 to 6 years in duration, and often involving experimental activities. Such CRPs allow a sharing of efforts on an international basis, foster team-building and benefit from the experience and expertise of researchers from all participating institutes. The IAEA is organizing a CRP on benchmarking severe accident computer codes for heavy water reactor (HWR) applications. The CRP scope includes defining the severe accident sequence and conducting benchmark analyses for HWRs, evaluating the capabilities of existing computer codes to predict important severe accident phenomena, and suggesting necessary code improvements and/or new experiments to reduce uncertainties. The CRP has been planned on the advice and with the support of the IAEA Nuclear Energy Department's Technical Working Groups on Advanced Technologies for HWRs. (author)

  17. SALE: Safeguards Analytical Laboratory Evaluation computer code

    International Nuclear Information System (INIS)

    Carroll, D.J.; Bush, W.J.; Dolan, C.A.

    1976-09-01

    The Safeguards Analytical Laboratory Evaluation (SALE) program implements an industry-wide quality control and evaluation system aimed at identifying and reducing analytical chemical measurement errors. Samples of well-characterized materials are distributed to laboratory participants at periodic intervals for determination of uranium or plutonium concentration and isotopic distributions. The results of these determinations are statistically-evaluated, and each participant is informed of the accuracy and precision of his results in a timely manner. The SALE computer code which produces the report is designed to facilitate rapid transmission of this information in order that meaningful quality control will be provided. Various statistical techniques comprise the output of the SALE computer code. Assuming an unbalanced nested design, an analysis of variance is performed in subroutine NEST resulting in a test of significance for time and analyst effects. A trend test is performed in subroutine TREND. Microfilm plots are obtained from subroutine CUMPLT. Within-laboratory standard deviations are calculated in the main program or subroutine VAREST, and between-laboratory standard deviations are calculated in SBLV. Other statistical tests are also performed. Up to 1,500 pieces of data for each nuclear material sampled by 75 (or fewer) laboratories may be analyzed with this code. The input deck necessary to run the program is shown, and input parameters are discussed in detail. Printed output and microfilm plot output are described. Output from a typical SALE run is included as a sample problem

  18. ASAMPSA-E guidance for level 2 PSA Volume 3. Verification and improvement of SAM strategies with L2 PSA

    International Nuclear Information System (INIS)

    Rahni, N.; Raimond, E.; Jan, P.; Lopez, J.; Loeffler, H.; Mildenberger, O.; Kubicek, J.; Vitazkova, J.; Ivanov, I.; Groudev, P.; Lajtha, G.; Serrano, C.; Zhabin, O.; Prosek, Andrej; Dirksen, G.; Yu, S.; Oury, L.; Hultqvist, G.

    2016-01-01

    For each NPP, severe accident management (SAM) strategies shall make use of components or systems and human resources to limit as far as possible the consequences of any severe accident on-site and off-site. L2 PSA is one of the tools that can be used to verify and improve these strategies. The present report (deliverable D40.5 of the project ASAMPSA-E) provides an opportunity for a comparison of objectives in the different countries in terms of SAM strategies verification and improvement. The report summarizes also experience of each partner (including potential deficiencies) involved in this activity, in order to derive some good practices and required progress, addressing: - SAM modeling in L2 PSA, - Positive and negative aspects in current SAM practices, - Discussion on possible criteria related to L2 PSA for verification and improvement: risk reduction (in relation with WP30 activities on risk metrics), reduction of uncertainties on the severe accident progression paths until NPP stabilization, reduction of human failure conditional probabilities (depending on the SAM strategy, the environmental conditions...), - Review with a perspective of verification and improvement of the main SAM strategies (corium cooling, RCS depressurization, control of flammable gases, reactivity control, containment function, containment pressure control, limitation of radioactive releases,...), - SAM strategies to be considered in the context of an extended L2 PSA (as far possible, depending on existing experience), taking into account all operating modes, accidents also occurring in the SFPs and long term and multi-unit accidents. The deliverable D40.5 is developed from the partners' experience. Many of the topics described here are beyond the common practices of L2 PSA applications: in some countries, L2 PSA application is limited to the calculations of frequencies of release categories with no formal requirement for SAM verification and improvement. (authors)

  19. Institute of nuclear power operations perspectives on PSA applications

    International Nuclear Information System (INIS)

    Webster, W.E.; Miller, W.J. Jr.

    1996-01-01

    The investment to develop a PSA is very substantial, and therefore, there is motivation to recover this investment through further use of the techniques used to develop it. It is not surprising that nuclear power plant staff are beginning to use PSA to make operational decisions. The Institute of Nuclear Power Operations is interested in those factors that impact the conduct of plant operations and therefore is actively monitoring the increased usage of PSA techniques. The purpose of this paper is to provide some thoughts and perspectives on the use of PSA as a factor in operational decision making, including decision making in activities performed by engineering, maintenance and operation personnel. (author)

  20. Extent of disease in recurrent prostate cancer determined by [(68)Ga]PSMA-HBED-CC PET/CT in relation to PSA levels, PSA doubling time and Gleason score.

    Science.gov (United States)

    Verburg, Frederik A; Pfister, David; Heidenreich, Axel; Vogg, Andreas; Drude, Natascha I; Vöö, Stefan; Mottaghy, Felix M; Behrendt, Florian F

    2016-03-01

    To examine the relationship between the extent of disease determined by [(68)Ga]PSMA-HBED-CC-PET/CT and the important clinical measures prostate-specific antigen (PSA), PSA doubling time (PSAdt) and Gleason score. We retrospectively studied the first 155 patients with recurrent prostate cancer (PCA) referred to our university hospital for [(68)Ga]PSMA-HBED-CC PET/CT. PET/CT was positive in 44%, 79% and 89% of patients with PSA levels of ≤1, 1-2 and ≥2 ng/ml, respectively. Patients with high PSA levels showed higher rates of local prostate tumours (p PSA and PSAdt were independent determinants of scan positivity and of extrapelvic lymph node metastases. PSAdt was the only independent marker of bone metastases (p = 0.001). Of 20 patients with a PSAdt PSA ≥2 ng/ml, 19 (95%) had a positive scan and 12 (60%) had M1a disease. Of 14 patients with PSA 6 months, only 5 (36%) had a positive scan and 1 (7%) had M1a disease. [(68)Ga]PSMA-HBED-CC PET/CT will identify PCA lesions even in patients with very low PSA levels. Higher PSA levels and shorter PSAdt are independently associated with scan positivity and extrapelvic metastases, and can be used for patient selection for [(68)Ga]PSMA-HBED-CC PET/CT.

  1. Regulatory requirements to the thermal-hydraulic and thermal-mechanical computer codes

    International Nuclear Information System (INIS)

    Vitkova, M.; Kalchev, B.; Stefanova, S.

    2006-01-01

    The paper presents an overview of the regulatory requirements to the thermal-hydraulic and thermal-mechanical computer codes, which are used for safety assessment of the fuel design and the fuel utilization. Some requirements to the model development, verification and validation of the codes and analysis of code uncertainties are also define. Questions concerning Quality Assurance during development and implementation of the codes as well as preparation of a detailed verification and validation plan are briefly discussed

  2. FRANTIC: a computer code for time dependent unavailability analysis

    International Nuclear Information System (INIS)

    Vesely, W.E.; Goldberg, F.F.

    1977-03-01

    The FRANTIC computer code evaluates the time dependent and average unavailability for any general system model. The code is written in FORTRAN IV for the IBM 370 computer. Non-repairable components, monitored components, and periodically tested components are handled. One unique feature of FRANTIC is the detailed, time dependent modeling of periodic testing which includes the effects of test downtimes, test overrides, detection inefficiencies, and test-caused failures. The exponential distribution is used for the component failure times and periodic equations are developed for the testing and repair contributions. Human errors and common mode failures can be included by assigning an appropriate constant probability for the contributors. The output from FRANTIC consists of tables and plots of the system unavailability along with a breakdown of the unavailability contributions. Sensitivity studies can be simply performed and a wide range of tables and plots can be obtained for reporting purposes. The FRANTIC code represents a first step in the development of an approach that can be of direct value in future system evaluations. Modifications resulting from use of the code, along with the development of reliability data based on operating reactor experience, can be expected to provide increased confidence in its use and potential application to the licensing process

  3. Validation of physics and thermalhydraulic computer codes for advanced Candu reactor applications

    International Nuclear Information System (INIS)

    Wren, D.J.; Popov, N.; Snell, V.G.

    2004-01-01

    Atomic Energy of Canada Ltd. (AECL) is developing an Advanced Candu Reactor (ACR) that is an evolutionary advancement of the currently operating Candu 6 reactors. The ACR is being designed to produce electrical power for a capital cost and at a unit-energy cost significantly less than that of the current reactor designs. The ACR retains the modular Candu concept of horizontal fuel channels surrounded by a heavy water moderator. However, ACR uses slightly enriched uranium fuel compared to the natural uranium used in Candu 6. This achieves the twin goals of improved economics (via large reductions in the heavy water moderator volume and replacement of the heavy water coolant with light water coolant) and improved safety. AECL has developed and implemented a software quality assurance program to ensure that its analytical, scientific and design computer codes meet the required standards for software used in safety analyses. Since the basic design of the ACR is equivalent to that of the Candu 6, most of the key phenomena associated with the safety analyses of ACR are common, and the Candu industry standard tool-set of safety analysis codes can be applied to the analysis of the ACR. A systematic assessment of computer code applicability addressing the unique features of the ACR design was performed covering the important aspects of the computer code structure, models, constitutive correlations, and validation database. Arising from this assessment, limited additional requirements for code modifications and extensions to the validation databases have been identified. This paper provides an outline of the AECL software quality assurance program process for the validation of computer codes used to perform physics and thermal-hydraulics safety analyses of the ACR. It describes the additional validation work that has been identified for these codes and the planned, and ongoing, experimental programs to extend the code validation as required to address specific ACR design

  4. Prediction of PSA bounce after permanent prostate brachytherapy for localized prostate cancer

    International Nuclear Information System (INIS)

    Kanai, Kunimitsu; Nakashima, Jun; Sugawara, Akitomo

    2009-01-01

    We aimed to calculate the frequency and features of the development of a prostate-specific antigen (PSA) bounce after prostate brachytherapy alone, to correlate the bounce with clinical and dosimetric factors and to identify factors that predict PSA bounce. PSA bounce was evaluated in 86 patients with T1-T2 prostate cancer who underwent radioactive seed implantation using iodine-125 (I-125) without hormonal therapy or external-beam radiation therapy (EBRT) from September 2004 to December 2007. A PSA bounce was defined as a rise of at least 0.4 ng/ml greater than a previous PSA level with a subsequent decline equal to, or less than, the initial nadir. Calculated by the Kaplan-Meier method, the incidence of PSA bounce at a 2-year follow-up was 26%. Median time to the PSA bounce was 15 months. Univariate analysis demonstrated that age, dose received by 90% of the prostate gland (D90), volume of gland receiving 100% of the prescribed dose (V100), and V150 were significantly associated with the PSA bounce, while pretreatment PSA level, Gleason score, pretreatment prostate volume, clinical T stage, and V200 were not. In multivariate analysis, age 67 years or less and D90 more than 180 Gy were identified as independent factors for predicting the PSA bounce (P<0.05). PSA bounce is not a rare phenomenon after prostate brachytherapy. It is more common in younger patients and patients receiving higher doses of radiation. (author)

  5. LIMBO computer code for analyzing coolant-voiding dynamics in LMFBR safety tests

    International Nuclear Information System (INIS)

    Bordner, G.L.

    1979-10-01

    The LIMBO (liquid metal boiling) code for the analysis of two-phase flow phenomena in an LMFBR reactor coolant channel is presented. The code uses a nonequilibrium, annular, two-phase flow model, which allows for slip between the phases. Furthermore, the model is intended to be valid for both quasi-steady boiling and rapid coolant voiding of the channel. The code was developed primarily for the prediction of, and the posttest analysis of, coolant-voiding behavior in the SLSF P-series in-pile safety test experiments. The program was conceived to be simple, efficient, and easy to use. It is particularly suited for parametric studies requiring many computer runs and for the evaluation of the effects of model or correlation changes that require modification of the computer program. The LIMBO code, of course, lacks the sophistication and model detail of the reactor safety codes, such as SAS, and is therefore intended to compliment these safety codes

  6. SIMCRI: a simple computer code for calculating nuclear criticality parameters

    International Nuclear Information System (INIS)

    Nakamaru, Shou-ichi; Sugawara, Nobuhiko; Naito, Yoshitaka; Katakura, Jun-ichi; Okuno, Hiroshi.

    1986-03-01

    This is a user's manual for a simple criticality calculation code SIMCRI. The code has been developed to facilitate criticality calculation on a single unit of nuclear fuel. SIMCRI makes an extensive survey with a little computing time. Cross section library MGCL for SIMCRI is the same one for the Monte Carlo criticality code KENOIV; it is, therefore, easy to compare the results of the two codes. SIMCRI solves eigenvalue problems and fixed source problems based on the one space point B 1 equation. The results include infinite and effective multiplication factor, critical buckling, migration area, diffusion coefficient and so on. SIMCRI is comprised in the criticality safety evaluation code system JACS. (author)

  7. Analysis of the Length of Braille Texts in English Braille American Edition, the Nemeth Code, and Computer Braille Code versus the Unified English Braille Code

    Science.gov (United States)

    Knowlton, Marie; Wetzel, Robin

    2006-01-01

    This study compared the length of text in English Braille American Edition, the Nemeth code, and the computer braille code with the Unified English Braille Code (UEBC)--also known as Unified English Braille (UEB). The findings indicate that differences in the length of text are dependent on the type of material that is transcribed and the grade…

  8. Accuracy assessment of a new Monte Carlo based burnup computer code

    International Nuclear Information System (INIS)

    El Bakkari, B.; ElBardouni, T.; Nacir, B.; ElYounoussi, C.; Boulaich, Y.; Meroun, O.; Zoubair, M.; Chakir, E.

    2012-01-01

    Highlights: ► A new burnup code called BUCAL1 was developed. ► BUCAL1 uses the MCNP tallies directly in the calculation of the isotopic inventories. ► Validation of BUCAL1 was done by code to code comparison using VVER-1000 LEU Benchmark Assembly. ► Differences from BM value were found to be ± 600 pcm for k ∞ and ±6% for the isotopic compositions. ► The effect on reactivity due to the burnup of Gd isotopes is well reproduced by BUCAL1. - Abstract: This study aims to test for the suitability and accuracy of a new home-made Monte Carlo burnup code, called BUCAL1, by investigating and predicting the neutronic behavior of a “VVER-1000 LEU Assembly Computational Benchmark”, at lattice level. BUCAL1 uses MCNP tally information directly in the computation; this approach allows performing straightforward and accurate calculation without having to use the calculated group fluxes to perform transmutation analysis in a separate code. ENDF/B-VII evaluated nuclear data library was used in these calculations. Processing of the data library is performed using recent updates of NJOY99 system. Code to code comparisons with the reported Nuclear OECD/NEA results are presented and analyzed.

  9. (Nearly) portable PIC code for parallel computers

    International Nuclear Information System (INIS)

    Decyk, V.K.

    1993-01-01

    As part of the Numerical Tokamak Project, the author has developed a (nearly) portable, one dimensional version of the GCPIC algorithm for particle-in-cell codes on parallel computers. This algorithm uses a spatial domain decomposition for the fields, and passes particles from one domain to another as the particles move spatially. With only minor changes, the code has been run in parallel on the Intel Delta, the Cray C-90, the IBM ES/9000 and a cluster of workstations. After a line by line translation into cmfortran, the code was also run on the CM-200. Impressive speeds have been achieved, both on the Intel Delta and the Cray C-90, around 30 nanoseconds per particle per time step. In addition, the author was able to isolate the data management modules, so that the physics modules were not changed much from their sequential version, and the data management modules can be used as open-quotes black boxes.close quotes

  10. Implementing a modular system of computer codes

    International Nuclear Information System (INIS)

    Vondy, D.R.; Fowler, T.B.

    1983-07-01

    A modular computation system has been developed for nuclear reactor core analysis. The codes can be applied repeatedly in blocks without extensive user input data, as needed for reactor history calculations. The primary control options over the calculational paths and task assignments within the codes are blocked separately from other instructions, admitting ready access by user input instruction or directions from automated procedures and promoting flexible and diverse applications at minimum application cost. Data interfacing is done under formal specifications with data files manipulated by an informed manager. This report emphasizes the system aspects and the development of useful capability, hopefully informative and useful to anyone developing a modular code system of much sophistication. Overall, this report in a general way summarizes the many factors and difficulties that are faced in making reactor core calculations, based on the experience of the authors. It provides the background on which work on HTGR reactor physics is being carried out

  11. Challenges and status of multi-unit PSA development in Canada

    International Nuclear Information System (INIS)

    Yalaoui, Smain

    2015-01-01

    Firstly, this paper discusses the issues and challenges related to the development of a Multi-Unit PSA (MU-PSA) and the general recommendations and conclusions from the MU-PSA Workshop organized by the CNSC in Ottawa, November 2014. This includes a discussion regarding the issue related to the methodological challenges in performing MU-PSA, the site-based risk metrics to be adopted, and the issue of risk aggregation across all hazards and all units. The paper also addresses the challenges for establishing site-based safety goals as the current safety goals were established on a per-unit basis. CNSC Staff efforts, both at the national and international level, on developing whole-site safety goals and guidance on MU-PSA and risk aggregation methodologies will also be discussed. Finally, the paper will provide a summary of the industry effort and road map for completing the pilot Whole-site PSA project for the Pickering Nuclear Generating Station, as requested by the Commission following to the public hearing for licence renewal in February 20 and May 29-31, 2013. (author)

  12. Development of PSA procedure for a criticality in reprocessing facilities

    International Nuclear Information System (INIS)

    Endo, Shigeki; Takanashi, Mitsuhiro; Ueda, Yoshinori

    2012-08-01

    Utilization of risk information for the nuclear safety regulation is being discussed in Japan. The development of probabilistic safety assessment (PSA) procedure is indispensable for the utilization of risk information. The Japan Nuclear Energy Safety Organization (JNES) has been conducting trial PSA to a model plant for major events, i.e. hydrogen explosion, solution boiling, rapid decomposition of TBP complexes, criticality, solvent fire, leakage of molten glass, leakage of high active concentrated liquid waste, loss of all AC electricity, drop of a fuel assembly, for the purpose of developing the PSA procedure for reprocessing facilities. For criticality events results of trial PSA were summarized as a report in which how to evaluate an amount of radioactive materials released from a facility and a health effect on the public were emphasized. Therefore, for criticality events the results of trial PSA were summarized in this report to emphasize procedures from making event progression scenarios to quantifying event sequences, which were not handled in the previous report, in a style of a document describing PSA procedures. (author)

  13. Structural dynamics in LMFBR containment analysis: a brief survey of computational methods and codes

    International Nuclear Information System (INIS)

    Chang, Y.W.; Gvildys, J.

    1977-01-01

    In recent years, the use of computer codes to study the response of primary containment of large, liquid-metal fast breeder reactors (LMFBR) under postulated accident conditions has been adopted by most fast reactor projects. Since the first introduction of REXCO-H containment code in 1969, a number of containment codes have evolved and been reported in the literature. The paper briefly summarizes the various numerical methods commonly used in containment analysis in computer programs. They are compared on the basis of truncation errors resulting in the numerical approximation, the method of integration, the resolution of the computed results, and the ease of programming in computer codes. The aim of the paper is to provide enough information to an analyst so that he can suitably define his choice of method, and hence his choice of programs

  14. Babesiosis PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    2012-04-25

    This 60 second PSA describes babesiosis, a preventable and treatable tickborne disease, including the signs and symptoms of infection and ways to prevent it.  Created: 4/25/2012 by Center for Global Health, Division of Parasitic Diseases and Malaria.   Date Released: 4/26/2012.

  15. Nuclear model codes available at the Nuclear Energy Agency Computer Program Library (NEA-CPL)

    International Nuclear Information System (INIS)

    Sartori, E.; Garcia Viedma, L. de

    1976-01-01

    This paper briefly outlines the objectives of the NEA-CPL and its activities in the field of Nuclear Model Computer Codes. A short description of the computer codes available from the CPL in this field is also presented. (author)

  16. Improvement of the computing speed of the FBR fuel pin bundle deformation analysis code 'BAMBOO'

    International Nuclear Information System (INIS)

    Ito, Masahiro; Uwaba, Tomoyuki

    2005-04-01

    JNC has developed a coupled analysis system of a fuel pin bundle deformation analysis code 'BAMBOO' and a thermal hydraulics analysis code ASFRE-IV' for the purpose of evaluating the integrity of a subassembly under the BDI condition. This coupled analysis took much computation time because it needs convergent calculations to obtain numerically stationary solutions for thermal and mechanical behaviors. We improved the computation time of the BAMBOO code analysis to make the coupled analysis practicable. 'BAMBOO' is a FEM code and as such its matrix calculations consume large memory area to temporarily stores intermediate results in the solution of simultaneous linear equations. The code used the Hard Disk Drive (HDD) for the virtual memory area to save Random Access Memory (RAM) of the computer. However, the use of the HDD increased the computation time because Input/Output (I/O) processing with the HDD took much time in data accesses. We improved the code in order that it could conduct I/O processing only with the RAM in matrix calculations and run with in high-performance computers. This improvement considerably increased the CPU occupation rate during the simulation and reduced the total simulation time of the BAMBOO code to about one-seventh of that before the improvement. (author)

  17. Construction and Quantification of the One Top model of the Fire Events PSA

    International Nuclear Information System (INIS)

    Kang, Dae Il; Lee, Yoon Hwan; Han, Sang Hoon

    2008-01-01

    KAERI constructed the one top model of the fire events PSA for Ulchin Unit 3 and 4 by using the 'mapping technique'. The mapping technique was developed for the construction and quantification of external events PSA models with a one top model for an internal events PSA. With 'AIMS', the mapping technique can be implemented by the construction of mapping tables. The mapping tables include fire rooms, fire ignition frequency, related initiating events, fire transfer events, and the internal PSA basic events affected by a fire. The constructed one top fire PSA model is based on previously conducted fire PSA results for Ulchin Unit 3 and 4. In this paper, we introduce the construction procedure and quantification results of the one top model of the fire events PSA by using the mapping technique. As the one top model of the fire events PSA developed in this study is based on the previous study, we also introduce the previous fire PSA approach focused on quantification

  18. Use of PSA for improving the safety of French PWRs

    International Nuclear Information System (INIS)

    Lanore, J.M.; Chambon, J.L.

    1994-06-01

    Two French PWR Probabilistic Safety Assessment (PSA) studies were conducted for the standardized PWR series of 900 and 1300 MWe. Both PSA 900 and PSA 1300 are level 1 PSAs, that means their objective is the evaluation of core meltdown frequency. These studies have some specific features, in particular the treatment of shutdown conditions, the treatment of long term post-accidental situations, and a wide use of French experience feedback. The PSAs are used for safety improvements of the French PWRs. Following the PSA results, several modifications to plants concerning the dominant sequences were decided. (R.P.). 2 refs., 4 figs

  19. Selection of a computer code for Hanford low-level waste engineered-system performance assessment

    International Nuclear Information System (INIS)

    McGrail, B.P.; Mahoney, L.A.

    1995-10-01

    Planned performance assessments for the proposed disposal of low-level waste (LLW) glass produced from remediation of wastes stored in underground tanks at Hanford, Washington will require calculations of radionuclide release rates from the subsurface disposal facility. These calculations will be done with the aid of computer codes. Currently available computer codes were ranked in terms of the feature sets implemented in the code that match a set of physical, chemical, numerical, and functional capabilities needed to assess release rates from the engineered system. The needed capabilities were identified from an analysis of the important physical and chemical process expected to affect LLW glass corrosion and the mobility of radionuclides. The highest ranked computer code was found to be the ARES-CT code developed at PNL for the US Department of Energy for evaluation of and land disposal sites

  20. Los Alamos radiation transport code system on desktop computing platforms

    International Nuclear Information System (INIS)

    Briesmeister, J.F.; Brinkley, F.W.; Clark, B.A.; West, J.T.

    1990-01-01

    The Los Alamos Radiation Transport Code System (LARTCS) consists of state-of-the-art Monte Carlo and discrete ordinates transport codes and data libraries. These codes were originally developed many years ago and have undergone continual improvement. With a large initial effort and continued vigilance, the codes are easily portable from one type of hardware to another. The performance of scientific work-stations (SWS) has evolved to the point that such platforms can be used routinely to perform sophisticated radiation transport calculations. As the personal computer (PC) performance approaches that of the SWS, the hardware options for desk-top radiation transport calculations expands considerably. The current status of the radiation transport codes within the LARTCS is described: MCNP, SABRINA, LAHET, ONEDANT, TWODANT, TWOHEX, and ONELD. Specifically, the authors discuss hardware systems on which the codes run and present code performance comparisons for various machines

  1. Programmable automation systems in PSA

    International Nuclear Information System (INIS)

    Pulkkinen, U.

    1997-06-01

    The Finnish safety authority (STUK) requires plant specific PSAs, and quantitative safety goals are set on different levels. The reliability analysis is more problematic when critical safety functions are realized by applying programmable automation systems. Conventional modeling techniques do not necessarily apply to the analysis of these systems, and the quantification seems to be impossible. However, it is important to analyze contribution of programmable automation systems to the plant safety and PSA is the only method with system analytical view over the safety. This report discusses the applicability of PSA methodology (fault tree analyses, failure modes and effects analyses) in the analysis of programmable automation systems. The problem of how to decompose programmable automation systems for reliability modeling purposes is discussed. In addition to the qualitative analysis and structural reliability modeling issues, the possibility to evaluate failure probabilities of programmable automation systems is considered. One solution to the quantification issue is the use of expert judgements, and the principles to apply expert judgements is discussed in the paper. A framework to apply expert judgements is outlined. Further, the impacts of subjective estimates on the interpretation of PSA results are discussed. (orig.) (13 refs.)

  2. PAD: a one-dimensional, coupled neutronic-thermodynamic-hydrodynamic computer code

    International Nuclear Information System (INIS)

    Peterson, D.M.; Stratton, W.R.; McLaughlin, T.P.

    1976-12-01

    Theoretical and numerical foundations, utilization guide, sample problems, and program listing and glossary are given for the PAD computer code which describes dynamic systems with interactive neutronics, thermodynamics, and hydrodynamics in one-dimensional spherical, cylindrical, and planar geometries. The code has been applied to prompt critical excursions in various fissioning systems (solution, metal, LMFBR, etc.) as well as to nonfissioning systems

  3. Study and application of Dot 3.5 computer code in radiation shielding problems

    International Nuclear Information System (INIS)

    Otto, A.C.; Mendonca, A.G.; Maiorino, J.R.

    1983-01-01

    The application of nuclear transportation code S sub(N), Dot 3.5, to radiation shielding problems is revised. Aiming to study the better available option (convergence scheme, calculation mode), of DOT 3.5 computer code to be applied in radiation shielding problems, a standard model from 'Argonne Code Center' was selected and a combination of several calculation options to evaluate the accuracy of the results and the computational time was used, for then to select the more efficient option. To illustrate the versatility and efficacy in the application of the code for tipical shielding problems, the streaming neutrons calculation along a sodium coolant channel is ilustrated. (E.G.) [pt

  4. Review process of PSA level 2 of KBR - Concept and Experience

    International Nuclear Information System (INIS)

    Andernacht, M.; Glaser, H.; Sonnenkalb, M.

    2013-01-01

    In Germany, a periodic safety review (PSR) has to be performed every ten years by the utility. In the past, a PSR only included a plant-specific probabilistic safety analysis (PSA) Level 1 study. Since a revised version of the German PSA guideline has been released in 2005, these plant-specific PSAs have to include a PSA Level 2, too. For the NPP Brokdorf (KBR) PSA Level 2 project, an agreement was reached between all parties involved that the study will be performed not as a part of the PSR process, but supplementary to it. This paper will focus on conclusions and findings from an ongoing parallel review process of the first full scope PSA Level 2 performed by the utility for KBR, a typical German PWR-1300. The responsible authority 'Ministerium fuer Soziales, Gesundheit, Familie, Jugend und Senioren des Landes Schleswig- Holstein' (MSGF) initiated this parallel review process in agreement with the utility KBR and the E.ON Kernkraft in 2006. The project will be completed soon. Such a review process allows that essential steps of the PSA will be reviewed and commented before the PSA Level 2 will be finished. So the benefit from this parallel review process is a significant enhancement of the quality and completeness of the PSA Level 2 study as the majority of the recommendations given by the review team has been taken over by the utility and the developer of the PSA, the AREVA NP company. Further, a common understanding and agreement will be reached at the end between all parties involved on the major topics of the PSA Level 2 study. The paper is followed by the slides of the presentation. (authors)

  5. Review process of PSA Level 2 of KBR. Concept and experience

    International Nuclear Information System (INIS)

    Andernacht, Martin; Glaser, Hendrik; Sonnenkalb, Martin

    2009-01-01

    In Germany, a periodic safety review (PSR) has to be performed every 10 years by the utility. In the past, a PSR only included a plant-specific probabilistic safety analysis (PSA) Level 1 study. For the NPP Brokdorf (KBR) PSA Level 2 project, an agreement was reached between all parties involved that the study will be performed not as a part of the PSR process, but supplementary to it. Since a revised version of the German PSA guideline has been released in 2005, these plant-specific PSAs have to include a PSA Level 2, too. This paper will focus on conclusions and findings from a ongoing parallel review process of the first full scope PSA Level 2 performed by the utility for KBR, a typical German PWR-1300. The responsible authority 'Ministerium fuer Soziales, Gesundheit, Familie, Jugend und Senioren des Landes Schleswig-Holstein (MSGF)' (Ministry of Social Affairs, Health, Family, Youth and Senior Citizens of Schleswig-Holstein) initiated this parallel review process in agreement with the utility KBR and the E.ON Kernkraft in 2006. The project will be completed soon. Such a review process allows that essential steps of the PSA will be reviewed and commented before the PSA Level 2 will be finished. So the benefit from this parallel review process is a significant enhancement of the quality and completeness of the PSA Level 2 study as the majority of the recommendations given by the review team has been taken over by the utility and the developer of the PSA, the Areva NP company. Further, a common understanding and agreement will be reached at the end between all parties involved on the major topics of the PSA Level 2 study. (orig.)

  6. A computer code for Tokamak reactor concepts evaluation

    International Nuclear Information System (INIS)

    Rosatelli, F.; Raia, G.

    1985-01-01

    A computer package has been developed which could preliminarily investigate the engineering configuration of a tokamak reactor concept. The code is essentially intended to synthesize, starting from a set of geometrical and plasma physics parameters and the required performances and objectives, three fundamental components of a tokamak reactor core: blanket+shield, TF magnet, PF magnet. An iterative evaluation of the size, power supply and cooling system requirements of these components allows the judgment and the preliminary design optimization on the considered reactor concept. The versatility of the code allows its application both to next generation tokamak devices and power reactor concepts

  7. TBCI and URMEL - New computer codes for wake field and cavity mode calculations

    International Nuclear Information System (INIS)

    Weiland, T.

    1983-01-01

    Wake force computation is important for any study of instabilities in high current accelerators and storage rings. These forces are generated by intense bunches of charged particles passing cylindrically symmetric structures on or off axis. The adequate method for computing such forces is the time domain approach. The computer Code TBCI computes for relativistic as well as for nonrelativistic bunches of arbitrary shape longitudinal and transverse wake forces up to the octupole component. TBCI is not limited to cavity-like objects and thus applicable to bellows, beam pipes with varying cross sections and any other nonresonant structures. For the accelerating cavities one also needs to know the resonant modes and frequencies for the study of instabilities and mode couplers. The complementary code named URMEL computes these fields for any azimuthal dependence of the fields in ascending order. The mathematical procedure being used is very safe and does not miss modes. Both codes together represent a unique tool for accelerator design and are easy to use

  8. Independent verification and validation testing of the FLASH computer code, Versiion 3.0

    International Nuclear Information System (INIS)

    Martian, P.; Chung, J.N.

    1992-06-01

    Independent testing of the FLASH computer code, Version 3.0, was conducted to determine if the code is ready for use in hydrological and environmental studies at various Department of Energy sites. This report describes the technical basis, approach, and results of this testing. Verification tests, and validation tests, were used to determine the operational status of the FLASH computer code. These tests were specifically designed to test: correctness of the FORTRAN coding, computational accuracy, and suitability to simulating actual hydrologic conditions. This testing was performed using a structured evaluation protocol which consisted of: blind testing, independent applications, and graduated difficulty of test cases. Both quantitative and qualitative testing was performed through evaluating relative root mean square values and graphical comparisons of the numerical, analytical, and experimental data. Four verification test were used to check the computational accuracy and correctness of the FORTRAN coding, and three validation tests were used to check the suitability to simulating actual conditions. These tests cases ranged in complexity from simple 1-D saturated flow to 2-D variably saturated problems. The verification tests showed excellent quantitative agreement between the FLASH results and analytical solutions. The validation tests showed good qualitative agreement with the experimental data. Based on the results of this testing, it was concluded that the FLASH code is a versatile and powerful two-dimensional analysis tool for fluid flow. In conclusion, all aspects of the code that were tested, except for the unit gradient bottom boundary condition, were found to be fully operational and ready for use in hydrological and environmental studies

  9. A restructuring of COR package for MIDAS computer code

    International Nuclear Information System (INIS)

    Park, S.H.; Kim, K.R.; Kim, D.H.

    2004-01-01

    The COR package, which calculates the thermal response of the core and the lower plenum internal structures and models the relocation of the core and lower plenum structural materials, has been restructured for the MIDAS computer code. MIDAS is being developed as an integrated severe accident analysis code with a user-friendly graphical user interface and a modernized data structure. To do this, the data transferring methods of the current MELCOR code are modified and adopted into the COR package. The data structure of the current MELCOR code using FORTRAN77 has a difficulty in grasping the meaning of the variables as well as a waste of memory. New features of FORTRAN90 make it possible to allocate the storage dynamically and to use the user-defined data type, which leads to an efficient memory treatment and an easy understanding of the code. Restructuring of the COR package addressed in this paper includes a module development, subroutine modification. The verification has been done by comparing the results of the modified code with those of the existing code. As the trends are similar to each other, it implies that the same approach could be extended to the entire code package. It is expected that the code restructuring will accelerated the code's domestication thanks to a direct understanding of each variable and an easy implementation of the modified or newly developed models. (author)

  10. Neutron spectrum unfolding using computer code SAIPS

    International Nuclear Information System (INIS)

    Karim, S.

    1999-01-01

    The main objective of this project was to study the neutron energy spectrum at rabbit station-1 in Pakistan Research Reactor (PARR-I). To do so, multiple foils activation method was used to get the saturated activities. The computer code SAIPS was used to unfold the neutron spectra from the measured reaction rates. Of the three built in codes in SAIPS, only SANDI and WINDOWS were used. Contribution of thermal part of the spectra was observed to be higher than the fast one. It was found that the WINDOWS gave smooth spectra while SANDII spectra have violet oscillations in the resonance region. The uncertainties in the WINDOWS results are higher than those of SANDII. The results show reasonable agreement with the published results. (author)

  11. A formal treatment of uncertainty sources in a level 2 PSA

    International Nuclear Information System (INIS)

    Ahn, Kwang Il; Yang, Joon Eon

    2003-01-01

    The methodological framework of the level 2 PSA appears to be currently standardized in a formalized fashion, but there have been different opinions on the way the sources of uncertainty are characterized and treated. This is primarily because the level 2 PSA deals with complex phenomenological processes that are deterministic in nature rather than random processes, and there are no probabilistic models characterizing them clearly. As a result, the probabilistic quantification of the level 2 PSA is often subjected to two sources of uncertainty: (a) incomplete modeling of accident pathways or different predictions for the behavior of phenomenological events and (b) expert-to-expert variation in estimating the occurrence probability of phenomenological events. While a clear definition of the two sources of uncertainty involved in the level 2 PSA makes it possible to treat an uncertainty in a consistent manner, careless application of these different sources of uncertainty may produce different conclusions in the decision-making process. The primary purpose of this paper is to characterize typical sources of uncertainty that would often be addressed in the level 2 PSA and their impacts on the PSA level 2 risk results. An additional purpose of this paper is to give a formal approach on how to combine random uncertainties addressed in the level 1 PSA with subjectivistic uncertainties addressed in the level 2 PSA

  12. Compilation of documented computer codes applicable to environmental assessment of radioactivity releases

    International Nuclear Information System (INIS)

    Hoffman, F.O.; Miller, C.W.; Shaeffer, D.L.; Garten, C.T. Jr.; Shor, R.W.; Ensminger, J.T.

    1977-04-01

    The objective of this paper is to present a compilation of computer codes for the assessment of accidental or routine releases of radioactivity to the environment from nuclear power facilities. The capabilities of 83 computer codes in the areas of environmental transport and radiation dosimetry are summarized in tabular form. This preliminary analysis clearly indicates that the initial efforts in assessment methodology development have concentrated on atmospheric dispersion, external dosimetry, and internal dosimetry via inhalation. The incorporation of terrestrial and aquatic food chain pathways has been a more recent development and reflects the current requirements of environmental legislation and the needs of regulatory agencies. The characteristics of the conceptual models employed by these codes are reviewed. The appendixes include abstracts of the codes and indexes by author, key words, publication description, and title

  13. Computer code to assess accidental pollutant releases

    International Nuclear Information System (INIS)

    Pendergast, M.M.; Huang, J.C.

    1980-07-01

    A computer code was developed to calculate the cumulative frequency distributions of relative concentrations of an air pollutant following an accidental release from a stack or from a building penetration such as a vent. The calculations of relative concentration are based on the Gaussian plume equations. The meteorological data used for the calculation are in the form of joint frequency distributions of wind and atmospheric stability

  14. Theoretical Atomic Physics code development IV: LINES, A code for computing atomic line spectra

    International Nuclear Information System (INIS)

    Abdallah, J. Jr.; Clark, R.E.H.

    1988-12-01

    A new computer program, LINES, has been developed for simulating atomic line emission and absorption spectra using the accurate fine structure energy levels and transition strengths calculated by the (CATS) Cowan Atomic Structure code. Population distributions for the ion stages are obtained in LINES by using the Local Thermodynamic Equilibrium (LTE) model. LINES is also useful for displaying the pertinent atomic data generated by CATS. This report describes the use of LINES. Both CATS and LINES are part of the Theoretical Atomic PhysicS (TAPS) code development effort at Los Alamos. 11 refs., 9 figs., 1 tab

  15. Immunohistochemical staining of precursor forms of prostate-specific antigen (proPSA) in metastatic prostate cancer.

    Science.gov (United States)

    Parwani, Anil V; Marlow, Cameron; Demarzo, Angelo M; Mikolajczyk, Stephen D; Rittenhouse, Harry G; Veltri, Robert W; Chan, Theresa Y

    2006-10-01

    Precursors of prostate-specific antigen (proPSA) have been previously shown to be more concentrated in prostate cancer tissue. This study characterizes the immunohistochemical staining (IHS) of proPSA forms in metastatic prostate cancer compared with prostate specific antigen (PSA) and prostatic acid phosphatase (PAP). A tissue microarray, consisting of 74 cases of metastatic prostate carcinoma and control tissues, was used. IHS, using monoclonal antibodies against proPSA with a truncated proleader peptide containing 2 amino acids ([-2]pPSA), native ([-5/-7]pPSA), PSA, and PAP, was analyzed. The monoclonal antibodies were specific for both benign and malignant prostatic glandular tissue. IHS with [-5/-7]pPSA showed the least number of cases with negative staining (3%), and the most number of cases with moderate or strong staining (76%). In the 60 cases where all 4 stains could be evaluated, none of them were negative for proPSA and positive for PSA or PAP, and all 7 cases that were negative for both PSA and PAP showed IHS to proPSA. [-5/-7]pPSA (native proPSA) may be a better marker than PSA and PAP in characterizing metastatic prostate adenocarcinoma, with most of the cases showing positivity for the marker. Even cases that were negative for PSA and PAP, were reactive for proPSA. Such enhanced detection is particularly important in poorly differentiated carcinomas involving metastatic sites where prostate carcinoma is a consideration. A panel of markers, including proPSA, should be performed when metastatic prostate carcinoma is in the differential diagnosis.

  16. Guidance to Risk-Informed Evaluation of Technical Specifications using PSA

    International Nuclear Information System (INIS)

    Baeckstroem, Ola; Haeggstroem, Anna; Maennistoe, Ilkka

    2010-04-01

    This report presents guidance for evaluation of Technical Specification conditions with PSA. It covers quality in PSA, how to verify that the PSA model is sufficiently robust and sufficiently complete and general requirements on methods. Acceptance criteria for evaluation of changes in the TS conditions are presented. As the probabilistic safety assessment (PSA) has developed over the years, it has demonstrated to constitute a useful tool for evaluating many aspects of the TS from a risk point of view. and in that way making the PSAs as well as the decision tools better. This also means that it will be possible to take credit for safety system overcapacity as well as inherent safety features and strength of non-safety classed systems. However, PSA is only one of the tools that shall be used in an evaluation process of TS changes (strengthening/relaxation). PSA is an excellent tool to be used to verify the importance, and thereby possibly relaxation, of TS requirements. But, since PSA is only one tool in the evaluation, it is not sufficient in itself for defining which equipment that shall or shall not have TS requirements. The purpose of this guidance document is to provide general requirements, requirements on methods and acceptance criteria on risk-informed evaluation of TS changes based on PSA. The purpose is not to provide a single solution. As part of the review of the TS conditions this guidance specify requirements on: - Quality verification of the PSA model; - Verification that the PSA model is sufficiently robust with regard to SSCs for which requirements both are and are not defined by the TS; - Verification that the SSCs, for which TS demands are to be evaluated, are modelled in a sufficient manner; - Methods for performing the evaluation; - Which evaluation criteria that shall be used (and how that is verified to be correct); - Acceptance criteria: This guidance also briefly discusses the documentation of the analysis of the TS changes. This guidance

  17. Guidance to risk-informed evaluation of technical specifications using PSA

    International Nuclear Information System (INIS)

    Baeckstroem, O.; Haeggstroem, A.; Maennistoe, I.

    2010-10-01

    This report presents guidance for evaluation of Technical Specification conditions with PSA. It covers quality in PSA, how to verify that the PSA model is sufficiently robust and sufficiently complete and general requirements on methods. Acceptance criteria for evaluation of changes in the TS conditions are presented. As the probabilistic safety assessment (PSA) has developed over the years, it has demonstrated to constitute a useful tool for evaluating many aspects of the TS from a risk point of view. and in that way making the PSAs as well as the decision tools better. This also means that it will be possible to take credit for safety system overcapacity as well as inherent safety features and strength of non-safety classed systems. However, PSA is only one of the tools that shall be used in an evaluation process of TS changes (strengthening/relaxation). PSA is an excellent tool to be used to verify the importance, and thereby possibly relaxation, of TS requirements. But, since PSA is only one tool in the evaluation, it is not sufficient in itself for defining which equipment that shall or shall not have TS requirements. The purpose of this guidance document is to provide general requirements, requirements on methods and acceptance criteria on risk-informed evaluation of TS changes based on PSA. The purpose is not to provide a single solution. As part of the review of the TS conditions this guidance specify requirements on: - Quality verification of the PSA model; - Verification that the PSA model is sufficiently robust with regard to SSCs for which requirements both are and are not defined by the TS; - Verification that the SSCs, for which TS demands are to be evaluated, are modelled in a sufficient manner; - Methods for performing the evaluation; - Which evaluation criteria that shall be used (and how that is verified to be correct); - Acceptance criteria: This guidance also briefly discusses the documentation of the analysis of the TS changes. This guidance

  18. Guidance to risk-informed evaluation of technical specifications using PSA

    Energy Technology Data Exchange (ETDEWEB)

    Baeckstroem, O.; Haeggstroem, A. (Scandpower AB, Stockholm (Sweden)); Maennistoe, I. (VTT, Helsingfors (Finland))

    2010-04-15

    This report presents guidance for evaluation of Technical Specification conditions with PSA. It covers quality in PSA, how to verify that the PSA model is sufficiently robust and sufficiently complete and general requirements on methods. Acceptance criteria for evaluation of changes in the TS conditions are presented. As the probabilistic safety assessment (PSA) has developed over the years, it has demonstrated to constitute a useful tool for evaluating many aspects of the TS from a risk point of view. and in that way making the PSAs as well as the decision tools better. This also means that it will be possible to take credit for safety system overcapacity as well as inherent safety features and strength of non-safety classed systems. However, PSA is only one of the tools that shall be used in an evaluation process of TS changes (strengthening/relaxation). PSA is an excellent tool to be used to verify the importance, and thereby possibly relaxation, of TS requirements. But, since PSA is only one tool in the evaluation, it is not sufficient in itself for defining which equipment that shall or shall not have TS requirements. The purpose of this guidance document is to provide general requirements, requirements on methods and acceptance criteria on risk-informed evaluation of TS changes based on PSA. The purpose is not to provide a single solution. As part of the review of the TS conditions this guidance specify requirements on: - Quality verification of the PSA model; - Verification that the PSA model is sufficiently robust with regard to SSCs for which requirements both are and are not defined by the TS; - Verification that the SSCs, for which TS demands are to be evaluated, are modelled in a sufficient manner; - Methods for performing the evaluation; - Which evaluation criteria that shall be used (and how that is verified to be correct); - Acceptance criteria: This guidance also briefly discusses the documentation of the analysis of the TS changes. This guidance

  19. Guidance to Risk-Informed Evaluation of Technical Specifications using PSA

    Energy Technology Data Exchange (ETDEWEB)

    Baeckstroem, Ola; Haeggstroem, Anna (Scandpower AB, Stockholm (Sweden)); Maennistoe, Ilkka (VTT, Helsingfors (Finland))

    2010-04-15

    This report presents guidance for evaluation of Technical Specification conditions with PSA. It covers quality in PSA, how to verify that the PSA model is sufficiently robust and sufficiently complete and general requirements on methods. Acceptance criteria for evaluation of changes in the TS conditions are presented. As the probabilistic safety assessment (PSA) has developed over the years, it has demonstrated to constitute a useful tool for evaluating many aspects of the TS from a risk point of view. and in that way making the PSAs as well as the decision tools better. This also means that it will be possible to take credit for safety system overcapacity as well as inherent safety features and strength of non-safety classed systems. However, PSA is only one of the tools that shall be used in an evaluation process of TS changes (strengthening/relaxation). PSA is an excellent tool to be used to verify the importance, and thereby possibly relaxation, of TS requirements. But, since PSA is only one tool in the evaluation, it is not sufficient in itself for defining which equipment that shall or shall not have TS requirements. The purpose of this guidance document is to provide general requirements, requirements on methods and acceptance criteria on risk-informed evaluation of TS changes based on PSA. The purpose is not to provide a single solution. As part of the review of the TS conditions this guidance specify requirements on: - Quality verification of the PSA model; - Verification that the PSA model is sufficiently robust with regard to SSCs for which requirements both are and are not defined by the TS; - Verification that the SSCs, for which TS demands are to be evaluated, are modelled in a sufficient manner; - Methods for performing the evaluation; - Which evaluation criteria that shall be used (and how that is verified to be correct); - Acceptance criteria: This guidance also briefly discusses the documentation of the analysis of the TS changes. This guidance

  20. Manpower development for safe operation of nuclear power plant. China. Probabilistic safety assessment. Activity: 5.1.2-Task-09. Technical report

    International Nuclear Information System (INIS)

    Leonard, M.T.; Kolaczkowski, A.M.

    1994-01-01

    The main objective of this mission was to provide assistance (primarily in the form of instruction via lecture) on applications of Probabilistic Safety Assessment (PSA) with emphasis on; data needs and methods for collection; description of current computer codes for PSA and applications; demonstrated applications of PSA and related achievements; and specific uses of PSA for operation, maintenance and inspection of commercial nuclear power plants