WorldWideScience

Sample records for ps booster injection

  1. Injection and transfer lines of the PS Booster

    CERN Multimedia

    Photographic Service

    1972-01-01

    In the foreground is the vacuum chamber for the 50 MeV proton beam coming from the Linac. The tank held by white frames houses the "Vertical Distributor", which deflects the Linac beam to the levels of the Booster's 4 superposed rings. After acceleration in the Booster, originally to 800 MeV, today to 1.4 GeV, the beams from the 4 rings are combined in the vertical plane and transfered to the 26 GeV PS. The "Recombination Line", intersecting the injection line, crosses the picture from left to right.

  2. The PS booster

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    The PS booster which accelerates protons from the linac at an energy of 50 MeV to an energy of 800 MeV before injecting them into the main magnet ring of the synchrotron. The booster consists of four superposed rings. In the photograph can be seen the input beam line from the linac and the output beam lines, where beams from the four booster levels have been combined into two beams before final recombination.

  3. The PS Booster hits 40

    CERN Multimedia

    Joannah Caborn Wengler

    2012-01-01

    Many accelerators’ "round" birthdays are being celebrated at CERN these days – the PS turned 50 in 2009, the SPS was 35 in 2011, and this year it's the turn of the PS Booster to mark its 40th anniversary. Originally designed to accelerate 1013 protons to 800 MeV, it has far exceeded its initial design performance over the years.   The PS Booster in the 1970s. Imagine the scene: a group of accelerator physicists staring expectantly at a monitor, when suddenly a shout of joy goes up as a signal flickers across the screen. Does that sound familiar? Well, turn the clock back 40 years (longer hair, wider trouser legs) and you have the situation at the PS Booster on 26 May 1972. On that day, beam was injected into the Booster for the first time. “It was a real buzz,” says Heribert Koziol, then Chairman of the Running-in Committee. “We were very happy – and also a little relieved – when the beam finally...

  4. LS1 Report: PS Booster prepares for beam

    CERN Multimedia

    Katarina Anthony

    2014-01-01

    With Linac2 already up and running, the countdown to beam in the LHC has begun! The next in line is the PS Booster, which will close up shop to engineers early next week. The injector will be handed over to the Operations Group who are tasked with getting it ready for active duty.   Taken as we approach the end of LS1 activities, this image shows where protons will soon be injected from Linac2 into the four PS Booster rings. Over the coming two months, the Operations Group will be putting the Booster's new elements through their paces. "Because of the wide range of upgrades and repairs carried out in the Booster, we have a very full schedule of tests planned for the machine," says Bettina Mikulec, PS Booster Engineer in Charge. "We will begin with cold checks; these are a wide range of tests carried out without beam, including system tests with power on/off and with varying settings, as well as verification of the controls system and timings." Amon...

  5. PS Booster - Festive colloquium

    CERN Multimedia

    2012-01-01

    A festive colloquium will be held to celebrate the 40th anniversary of the PS Booster on Friday, 28 September at 2 p.m. in the CERN council chamber. The meeting will be open to everybody. Read more on the PS Booster in the CERN Bulletin and in the CERN Courier.

  6. The PS Booster, PS and SPS Magnets for the next 25 years

    CERN Document Server

    Tommasini, D

    2010-01-01

    This note provides information and analysis on the present status of the magnets installed in the CERN Proton Synchrotron Booster (PSB), the Proton Synchrotron (PS) and the Super Proton Synchrotron (SPS) in view of their possible operation for the next 25 years. The note does not cover the magnets installed in the transfer lines, neither it covers the fast injection/extraction magnets (septa and kickers).

  7. The 1.4 GeV PS Booster in its tunnel.

    CERN Multimedia

    Patrice Loïez

    2002-01-01

    The PS Improvement Programme, launched as early as 1964, had a "Booster" as the key element in the quest for higher beam intensity and density. These were limited in the PS at injection of the 50 MeV proton beam from the linac by the incoherent (Laslett-) Q-shift. Boosting the linac beam to 800 MeV would raise the PS intensity limit by an order of magnitude, from 1E12 protons per pulse to 1E13. The main motivation was the supply of intense beams to the ISR. Soon, the Booster proved to be crucial for the neutral current experiment. A unique feature of the Booster are its 4 superposed rings. Its lattice is also unusual: between its 32 bending magnets, every second straight section contains a quadrupole triplet (F,D,F), while the alternate ones are drift spaces (mostly filled with essential components like septa, kickers, RF-cavities, etc.). In each picture we see one of the 16 periods. Following the direction of the beam from right to left: a bending magnet (green); an empty straight section; a bending magnet; ...

  8. Vertical septum magnets for distributing the beam to the 4 PS Booster rings

    CERN Multimedia

    Ordan, Julien Marius

    2017-01-01

    To facilitate H- injection from Linac4 to the PS Booster via the transfer line the BI.SMV10 (Booster Injection Septum Magnet Vertical) provides the vertical deflection of the 160 MeV H- beam to rings 1, 2 and 4 of the Booster. Currently this system is capable of deflecting 50 MeV protons and comprises an assembly of ferrite type magnets in an “omega” section vacuum tank (see fig. 1). The current system shall be replaced with a UHV compatible vacuum chamber incorporating 3 sets of double septum magnets, pulsed from 3 individual power supplies via transformers with 12:1 ratio.

  9. Evolution of High Intensity Beams in the CERN PS Booster after H⁻ Injection and Phase Space Painting

    CERN Document Server

    Cieslak-Kowalska, Magdalena; Benedetto, Elena; Bracco, Chiara

    2016-01-01

    With the LHC Injector Upgrade (LIU) project, the injection energy of PS Booster (PSB) ' first circular accelerator in the LHC injector chain ' will be raised from 50 MeV to 160 MeV and the present multiturn injection will be upgraded to H⁻ injection with transverse and longitudinal painting. In the scope of this project, it is planned to double the beam intensities, profiting from the fact that the βγ2 factor will be two times larger (0.35 at 50 MeV and 0.71 at 160 MeV), so the resulting tune spread driven by a direct space charge should remain similar. This paper describes the feasibility to double the intensity of high intensity and large emittance beams, looking into the evolution under space charge and taking into account losses constrains in the ring and in the extraction lines.

  10. Preparations for Upgrading the RF Systems of the PS Booster

    CERN Document Server

    Albright, Simon; Shaposhnikova, Elena

    2016-01-01

    The accelerators of the LHC injector chain need to be upgraded to provide the HL-LHC beams. The PS Booster, the first synchrotron in the LHC injection chain, uses three different RF systems (first, second and up to tenth harmonic) in each of its four rings. As part of the LHC Injector Upgrade the current ferrite RF systems will be replaced with broadband Finemet cavities, increasing the flexibility of the RF system. A Finemet test cavity has been installed in Ring 4 to investigate its effect on machine performance, especially beam stability, during extensive experimental studies. Due to large space charge impedance Landau damping is lost through most of the cycle in single harmonic operation, but is recovered when using the second harmonic and controlled longitudinal emittance blow-up. This paper compares beam parameters during acceleration with and without the Finemet test cavity. Comparisons were made using beam measurements and simulations with the BLonD code based on a full PS Booster impedance model. Thi...

  11. Status of the Upgrade of the CERN PS Booster

    CERN Document Server

    Hanke, K; Angoletta, M; Bartmann, W; Bartolome, S; Benedetto, E; Bertone, C; Blas, A; Bonnal, P; Borburgh, J; Bozzini, D; Butterworth, A; Carli, C; Carlier, E; Cole, J; Dahlen, P; Delonca, M; Dobers, T; Findlay, A; Froeschl, R; Hansen, J; Hay, D; Jensen, S; Lacroix, J; Le Roux, P; Lopez Hernandez, L; Maglioni, C; Masi, A; Mason, G; Mathot, S; Mikulec, B; Muttoni, Y; Newborough, A; Nisbet, D; Olek, S; Paoluzzi, M; Perillo-Marcone, A; Pittet, S; Puccio, B; Raginel, V; Riffaud, B; Ruehl, I; Sarrió Martínez, A; Tan, J; Todd, B; Venturi, V; Weterings, W

    2013-01-01

    The CERN PS Booster (PSB) is presently undergoing an ambitious consolidation and upgrade program within the frame of the LHC Injectors Upgrade (LIU) project. This program comprises a new injection scheme for H- ions from CERN’s new Linac4, the replacement of the main RF systems and an energy upgrade of the PSB rings from 1.4 to 2 GeV which includes the replacement of the main magnet power supply as well as the upgrade of the extraction equipment. This paper describes the status and plans of this work program.

  12. Linac4, a New Injector for the CERN PS Booster

    CERN Document Server

    Garoby, R; Gerigk, F; Hanke, K; Lombardi, A; Pasini, M; Rossi, C; Sargsyan, E; Vretenar, M

    2006-01-01

    The first bottle-neck towards higher beam brightness in the LHC injector chain is due to space charge induced tune spread at injection into the CERN PS Booster (PSB). A new injector called Linac4 is proposed to remove this limitation. Using RF cavities at 352 and 704 MHz, it will replace the present 50 MeV proton Linac2, and deliver a 160 MeV, 40 mA H- beam. The higher injection energy will reduce space charge effects by a factor of 2, and charge exchange will drastically reduce the beam losses at injection. Operation will be simplified and the beam brightness required for the LHC ultimate luminosity should be obtained at PS ejection. Moreover, for the needs of non-LHC physics experiments like ISOLDE, the number of protons per pulse from the PSB will increase by a significant factor. This new linac constitutes an essential component of any of the envisaged LHC upgrade scenarios. It is also designed to become the low energy part of a future 3.5 GeV, multi-megawatt superconducting linac (SPL). The present desig...

  13. Dump and Current Measurement of Unstripped H`ions at the Injection from the CERN LINAC4 Into the PS Booster

    CERN Document Server

    Chamizo, R; Goddard, B; Mereghetti, A; Versaci, R; Weterings, W

    2010-01-01

    Linac4 is the new H- linear accelerator under construction at CERN aiming to double the brightness of the beam injected to the CERN PS Booster (PSB) for delivering proton beams to experiments or further CERN accelerators, down to the LHC. The injection system in the PSB is based on the H- charge exchange where the 160 MeV H- beam is converted into an H+ beam by stripping the electrons with a carbon foil. A beam dump located inside a pulsed magnet for the injection bump will intercept the unstripped ions (H0 and H-) and measure the collected charge to detect the relative efficiency and degradation of the stripping foil. The challenge of the dump design is to meet the requirements of a beam dump providing a current measurement and at the same time minimizing the perturbation of the magnetic field of the surrounding pulsed magnet. This paper describes all phases of the dump design and the main issues related to its integration in the line.

  14. Septa and Distributor Developments for H- Injection into the Booster from LINAC4

    CERN Document Server

    Borburgh, J; Fowler, T; Hourican, M; Weterings, W

    2008-01-01

    The construction of Linac4 requires the modification of the existing injection system of the CERN PS Booster. A new transfer line will transport 160 MeV H- ions to this machine. A system of 5 pulsed magnets (BIDIS) and 3 vertical septa (BISMV) will distribute and inject the Linac pulses into the four-vertically separated Booster rings. Subsequently the beam will be injected horizontally, using a local bump created with bumpers (BS magnets) to bring the injected H- beam together with the orbiting proton beam onto the stripper foil. To accommodate the injected H- beam, the first of the BS magnets will have to be a septum-like device, deflecting only the orbiting beam. This paper highlights the requirements and technical issues and describes the solutions to be adopted for both the BIDIS and BISMV. The results of initial prototype testing of the BIDIS magnet will also be presented.

  15. PS Booster Orbit Correction

    CERN Document Server

    Chanel, M; Rumolo, G; Tomás, R; CERN. Geneva. AB Department

    2008-01-01

    At the end of the 2007 run, orbit measurements were carried out in the 4 rings of the PS Booster (PSB) for different working points and beam energies. The aim of these measurements was to provide the necessary input data for a PSB realignment campaign during the 2007/2008 shutdown. Currently, only very few corrector magnets can be operated reliably in the PSB; therefore the orbit correction has to be achieved by displacing (horizontally and vertically) and/or tilting some of the defocusing quadrupoles (QDs). In this report we first describe the orbit measurements, followed by a detailed explanation of the orbit correction strategy. Results and conclusions are presented in the last section.

  16. Measuring target for the PS Booster

    CERN Multimedia

    1971-01-01

    The measuring target for the PS Booster (originally 800 MeV, now 1.4 GeV). It measures the size of the beam by destroying all particles with amplitudes greater than the size of the fork, the position and width of which are adjustable. The plunging time is only 20 ms and the acceleration at the tip of the fork reaches 90 g. The servo-controlled linear motor is shown detached from the mechanism. See also 7602008.

  17. Booster gold beam injection efficiency and beam loss

    International Nuclear Information System (INIS)

    Zhang, S.Y.; Ahrens, L.A.

    1998-01-01

    The Relativistic Heavy Ion Collider (RHIC) at the BNL requires the AGS to provide Gold beam with the intensity of 10 9 ions per bunch. Over the years, the Tandem Van de Graaff has provided steadily increasing intensity of gold ion beams to the AGS Booster. However, the gold beam injection efficiency at the Booster has been found to decrease with the rising intensity of injected beams. As the result, for Tandem beams of the highest intensity, the Booster late intensity is lower than with slightly lower intensity Tandem beam. In this article, the authors present two experiments associated with the Booster injection efficiency and beam intensity. One experiment looks at the Booster injection efficiency by adjusting the Tandem beam intensity, and another looks at the beam life time while scraping the beam in the Booster. The studies suggest that the gold beam injection efficiency at the AGS Booster is related to the beam loss in the ring, rather than the intensity of injected beam or circulating beam. A close look at the effect of the lost gold ion at the Booster injection leads to the prediction that the lost gold ion creates large number of positive ions, and even larger number of electrons. The lost gold beam is also expected to create large numbers of neutral particles. In 1998 heavy ion run, the production of positive ions and electrons due to the lost gold beam has been observed. Also the high vacuum pressure due to the beam loss, presumably because of the neutral particles it created, has been measured. These results will be reported elsewhere

  18. Feasibility Study of the PS Injection for 2 GeV LIU Beams with an Upgraded KFA-45 Injection Kicker System Operating in Short Circuit Mode

    CERN Document Server

    Kramer, Thomas; Borburgh, Jan; Ducimetière, Laurent; Feliciano, Luis; Ferrero Colomo, Alvaro; Goddard, Brennan; Sermeus, Luc

    2016-01-01

    Under the scope of the LIU project the CERN PS Booster to PS beam transfer will be modified to match the requirements for the future 2 GeV beams. This paper describes the evaluation of the proposed upgrade of the PS injection kicker. Different schemes of an injection for LIU beams into the PS have been outlined in the past already under the aspect of individual transfer kicker rise and fall time performances. Homogeneous rise and fall time requirements in the whole PSB to PS transfer chain have been established which allowed to consider an upgrade option of the present injection kicker system operated in short circuit mode. The challenging pulse quality constraints require an improvement of the flat top and post pulse ripples. Both operation modes, terminated and short circuit mode are analysed and analogue circuit simulations for the present and upgraded system are outlined. Recent measurements on the installed kickers are presented and analysed together with the simulation data. First measurements verifying...

  19. Position pickup of the PS Booster

    CERN Multimedia

    CERN PhotoLab

    1975-01-01

    The beam position around the 4 rings of the PS Booster (originally 800 MeV, now 1.4 GeV), is measured with electrostatic pickups (PU). They consist of a ceramic cylinder forming part of the vacuum chamber, and, in order to save space, they are located inside the multipole lenses. The inside of the ceramic is coated with a metallic layer, into which the form of the electrodes was cut by computer-controlled micro-sandblasting. Each PU has a pair of horizontal and a pair of vertical electrodes, as well as a separate intensity-sensing circular electrode.

  20. CERN's PS Booster LLRF renovation : plans and initial beam tests

    CERN Document Server

    Angoletta, ME; Butterworth, A; Findlay, A; Leinonen, PM; Molendijk, JC; Pedersen, F; Sanchez-Quesada, J; Schokker, M

    2010-01-01

    In 2008 a project was started to renovate the CERN's PS Booster (PSB) low-level RF (LLRF). Required LLRF capabilities include frequency program, beam phase, radial and synchronization loops. The new LLRF will control the signals feeding the three RF cavities present in each ring; it will also shape the beam in a dual harmonic mode, operate a bunch splitting and create a longitudinal blow-up. The main benefits of this new LLRF are its full remote and cycle-to-cycle controllability, built-in observation capability and flexibility. The overall aim is to improve the robustness, maintainability and reliability of the PSB operation and to make it compatible with the injection from the future Linac4. This paper outlines the main characteristics of the software and hardware building blocks. Initial beam test results and hints on the main milestones and future work are also given.

  1. LS1 Report: first beams in the Booster

    CERN Multimedia

    Anaïs Schaeffer

    2014-01-01

    On Monday, 2 June, the Operations Group injected the first beams into the PS Booster (PSB). The PSB, the second machine in the LHC injector chain to be recommissioned (Linac2 was the first), also provides beams for non-LHC experiments, some of which will need beams for physics as early as this summer.   The PS Booster. The Operations Group has been back in control of the PS Booster for a month now, having taken over where the engineers and experts of the EN Department, who were responsible for the maintenance work, left off. The group first ran tests with no beam (known as “cold check-out”) to check and requalify all the machine instrumentation, from the control room to the ring itself. Now in beam mode, the Booster is being prepared both to begin supplying the PS at the end of June and, above all, for physics to restart in the ISOLDE experimental area. The PS Booster console in the CERN Control Centre. “We have around 15 types of beams to ‘prepa...

  2. Multipole stack for the 4 rings of the PS Booster

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    The PS Booster (originally 800 MeV, now 1.4 GeV) saw first beam in 1972, routine operation began in 1973. The strive for ever higher intensities required the addition of multipoles. Manufacture of 8 stacks of multipoles was launched in 1974, for installation in 1976. For details, see 7511120X.

  3. SIMULATIONS OF BOOSTER INJECTION EFFICIENCY FOR THE APS-UPGRADE

    Energy Technology Data Exchange (ETDEWEB)

    Calvey, J.; Borland, M.; Harkay, K.; Lindberg, R.; Yao, C.-Y.

    2017-06-25

    The APS-Upgrade will require the injector chain to provide high single bunch charge for swap-out injection. One possible limiting factor to achieving this is an observed reduction of injection efficiency into the booster synchrotron at high charge. We have simulated booster injection using the particle tracking code elegant, including a model for the booster impedance and beam loading in the RF cavities. The simulations point to two possible causes for reduced efficiency: energy oscillations leading to losses at high dispersion locations, and a vertical beam size blowup caused by ions in the Particle Accumulator Ring. We also show that the efficiency is much higher in an alternate booster lattice with smaller vertical beta function and zero dispersion in the straight sections.

  4. Injection system of teh SSC Medium Energy Booster

    International Nuclear Information System (INIS)

    Mao, N.; Gerig, R.; McGill, J.; Brown, K.

    1994-04-01

    The Medium Energy Booster (MEB) is the third of the SSCL accelerators and the largest of the resistive magnet synchrotrons. It accelerates protons from an injection momentum of 12 GeV/c to a top momentum of 200 GeV/c. A beam injection system has been designed to inject the beam transferred from the Low Energy Booster onto the MEB closed orbit in the MEB injection insertion region. The beam is injected via a vertical bending Lambertson septum magnet and a horizontal kicker with appropriate matching and very little beam loss and emittance dilution. The beam optics of the injection system is described in this paper. The required parameters of the Lambertson septum magnet and the injection kicker are given

  5. 3D Emittances Tailoring Techniques and Optimization with Space Charge for the Future CERN PS Booster Operations with Linac4

    CERN Document Server

    Forte, Vincenzo; Benedetto, Elena; Bracco, Chiara; Cieslak-Kowalska, Magdalena; Di Giovanni, Gian Piero

    2016-01-01

    In the frame of the LIU (LHC Injectors Upgrade) project, the CERN PS Booster is going to be renovated to host a new H⁻ charge-exchange injection from the Linac4. One important feature of the new injection scheme is the possibility to tailor a wide range of 3D emittances for CERN's different users in an intensity span in the order of 5·10⁹ to 1.6·10¹³ protons per PSB ring. This paper gives an overview of 3D multi-turn injection techniques, focusing on the future LHC beams, which aim at reaching high brightness, and on highest intensity beams (ISOLDE), where losses are the main concern. Complete RF capture simulations and transverse injection maps, including space charge effects, are presented and also intended to be used during the commissioning with Linac4.

  6. Study of an energy upgrade of the CERN PS Booster

    CERN Document Server

    Hanke, K; Angoletta, M E; Bartmann, W; Bartolome, S; Bertone, C; Blas, A; Borburgh, J; Bozzini, D; Butterworth, A; Carli, C; Dahlen, P; Dobers, T; Findlay, A; Folch, R; Gilbert, N; Hansen, J; Hermanns, T; Jensen, S; Le Roux, P; Lopez-Hernandez, L A; Mahner, E; Masi, A; Mikulec, B; Muttoni, Y; Newborough, A; Nisbet, D; Nonis, M; Olek, S; Paoluzzi, M; Pittet, S; Puccio, B; Raginel, V; Ruehl, I; Tan, J; Todd, B; Weterings, W; Widorski, W

    2011-01-01

    CERN’s LHC injector chain will have to deliver beams with ultimate brilliance as the LHC is heading for increased luminosity in the coming years. In order to overcome bottlenecks in the injector chain, an increase of the beam transfer energy from the CERN Proton Synchrotron Booster (PSB) to the Proton Synchrotron (PS) has been investigated as a possible upgrade scenario. This paper gives an overview of the technical solutions and summarizes the conclusions of the feasibility study.

  7. Charge exchange injection for Nuclotron and Nuclotron booster

    International Nuclear Information System (INIS)

    Dinev, D.; Mikhajlov, V.

    2000-01-01

    The acceleration of polarized beams is between the major items in the JINR LHE's heavy ion superconducting synchrotron Nuclotron research programme. One effective way to increase the intensities of polarized deuteron beams is the application of the charge exchange injection into the Nuclotron. The paper represents the results of a new analytical description of the heavy ion stripping injection based on the Boltzmann kinetic equation. Expressions for the ion density evolution in the transverse phase plane for the emittance growth due to the elastic scattering and to energy losses in the stripping foil and for the number of successfully stored particles have been derived. These results have been applied to the stripping injection of polarized deuterons into the Nuclotron as well as to the stripping injection of heavy ions into the now under consideration Nuclotron rapid cycling booster. It has been shown that an estimated 40-fold intensity gain could be achieved for the stripping injection of polarized D - into the Nuclotron and that an effective stripping injection of light and medium ions into the booster could be realized

  8. The injection and extraction of SSRF booster

    International Nuclear Information System (INIS)

    Li Yuan; Li Haohu; Liu Guimin; Li Deming

    2008-01-01

    The layout of injection and extraction system were introduced in this paper. The horizontal and vertical injection acceptance are about 23 πmm·mrad and 37 πmm·mrad, respectively, while emittance of the injected beam is 9 πmm·mrad (3σ). This ensures the high injection efficiency. Three slow kickers can form a good bump. The inside position of the entrance of septum is set to 15 mm, where the bumped beam and the extraction beam are 10 mm and 22 mm, respectively, far from the booster central orbit. (authors)

  9. Accelerating RF cavity of the Booster

    CERN Multimedia

    CERN PhotoLab

    1981-01-01

    Each of the 4 PS Booster rings has a single accelerating cavity. It consists of 2 quarter-wave ferrite-loaded resonators. There are 2 figure-of-eight loops on the ferrite loads for tuning the frequency throughout the acceleration cycle, from 3 to 8 MHz (from 50 MeV at injection to the original Booster energy of 800 MeV, 2 GeV today). The cavities have a flat design, to fit the ring-to-ring distance of 36 cm. The tube for forced-air cooling is visible in the left front. See also 8301084.

  10. Accelerating RF cavity of the Booster

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    Each of the 4 PS Booster rings has a single accelerating cavity.It consists of 2 quarter-wave ferrite-loaded resonators. 2 figure-of-eight loops tune the frequency throughout the accelerating cycle, from 3 to 8 MHz (from 50 MeV at injection to the original Booster energy of 800 MeV, 2 GeV today). The cavities have a flat design, to fit the ring-to-ring distance of 36 cm, and are forced-air cooled. The 2 round objects in the front-compartments are the final-stage power-tetrodes. See also 8111095.

  11. Multipole Stack for the 800 MeV PS Booster

    CERN Multimedia

    1975-01-01

    The 800 MeV PS Booster had seen first beam in its 4 superposed rings in 1972, routine operation began in 1973. In the strive for ever higher beam intensities, the need for additional multipole lenses became evident. After detailed studies, the manufacture of 8 stacks of multipoles was launched in 1974. Each stack consists of 4 superposed multipoles and each multipole has 4 concentric shells. From the innermost to the outermost shell, Type A contains octupole, skew-octupole, sextupole, skew-sextupole. Type B contains skew-octupole, skew-sextupole, vertical dipole, horizontal dipole. Completion of installation in 1976 opened the way to higher beam intensities. M. Battiaz is seen here with a multipole stack and its many electrical connections.

  12. Injection Bucket Jitter Compensation Using Phase Lock System at Fermilab Booster

    Energy Technology Data Exchange (ETDEWEB)

    Seiya, K. [Fermilab; Drennan, C. [Fermilab; Pellico, W. [Fermilab; Chaurize, S. [Fermilab

    2017-05-12

    The extraction bucket position in the Fermilab Booster is controlled with a cogging process that involves the comparison of the Booster rf count and the Recycler Ring revolution marker. A one rf bucket jitter in the ex-traction bucket position results from the variability of the process that phase matches the Booster to the Recycler. However, the new slow phase lock process used to lock the frequency and phase of the Booster rf to the Recycler rf has been made digital and programmable and has been modified to correct the extraction notch position. The beam loss at the Recycler injection has been reduced by 20%. Beam studies and the phase lock system will be discussed in this paper.

  13. PS BOOSTER BEAM TESTS OF THE NEW DIGITAL BEAM CONTROL SYSTEM FOR LEIR

    CERN Document Server

    Angoletta, Maria Elena; Bento, J; De Long, J H; Findlay, A; Matuszkiewicz, P; Pedersen, F; Salom-Sarasqueta, A; CERN. Geneva. AB Department

    2005-01-01

    We have been developing a scaled-down prototype of the new digital beam control and cavity servoing system for CERN’s Low Energy Ion Ring (LEIR) slated for commissioning in 2005. The system’s hardware and software, developed as part of a CERN-BNL collaboration, are based on new all-digital technology already deployed at BNL's AGS Booster. The system relies on VME modules, carrying Digital Signal Processors (DSPs) as well as Field Programmable Gate Arrays (FPGAs), and daughter cards. New concepts deployed include software implementation, through DSPs & FPGAs, of functions traditionally executed by analogue hardware, such as reference-functions and timings generation. Additionally, a user-selectable digital data acquisition functionality provides diagnostic and troubleshoot access points, a new feature which is very useful in a digital system. The scaled-down prototype implements frequency program, radial steering, phase and radial loops capabilities and it has been tested in CERN's PS Booster (PSB) dur...

  14. Emittance Measurements For Future LHC Beams Using The PS Booster Measurement Line

    CERN Document Server

    Abelleira, Jose; Mikulec, Bettina; Di Giovanni, Gian Piero; CERN. Geneva. ATS Department

    2017-01-01

    The CERN PS Booster measurement line contains three pairs of SEM grids separated by drift space that measures the beam size in both planes. The combined analysis of these grids allows calculating a value for the transverse beam emittances. The precision of such a measurement depends on the ratio of RMS beam size and wire spacing. Within the LIU-PSB upgrade the extraction kinetic energy of the PSB will be increased from the current 1.4 GeV to 2.0 GeV. This will result in smaller transverse beam sizes for some of the future beams. The present layout of the transverse emittance measurement line is reviewed to verify if it will satisfy future requirements.

  15. Design study of the large hadron electron collider and a rapid cycling synchrotron as alternative to the PS booster upgrade at CERN

    International Nuclear Information System (INIS)

    Fitterer, Miriam

    2013-01-01

    With the Large Hadron Collider (LHC) the exploration of particle physics at center of mass energies at the TeV scale has begun. To extend the discovery potential of the LHC, a major upgrade is foreseen around 2020 of the LHC itself and the LHC injectors - the chain of accelerators preparing the beam for the LHC. One of the injectors - the second one in the chain - is the Proton Synchrotron (PS) Booster. Its performance is currently limited by the space-charge effect, which is the effect of the electromagnetic field of the particle beam on itself. This effect becomes weaker with higher energy, and therefore an energy upgrade of the PS Booster to 2 GeV maximum beam energy is foreseen. As the PS Booster is with its 40 years already an old machine, the construction of a new accelerator, a Rapid Cycling Synchrotron (RCS), to replace the PS Booster has been proposed. In this thesis different options for the beam guidance in the RCS - referred to as lattice and optics - are studied, followed by a more general comparison of different lattices and optics and their performance under consideration of the space-charge effect. To further complement the LHC physics program, also the possibility of deep inelastic lepton-nucleon scattering at the LHC has been suggested, referred to as Large Hadron Electron Collider (LHeC). In this case the proton beam of the LHC collides with the electron beam, which is accelerated in a separate newly built machine. Two options are considered as electron accelerator: a new energy recovery linac - the Linac-Ring option - and the installation of an electron ring in the existing LHC tunnel - the Ring-Ring option. One of the main challenges of the Ring-Ring option is the integration of the electron ring in the current LHC tunnel. A layout, lattice and optics of the electron accelerator is developed in this thesis, which meets the requirements with regard to integration and reaches the beam parameters demanded by the particle physics experiments.

  16. Design study of the large hadron electron collider and a rapid cycling synchrotron as alternative to the PS booster upgrade at CERN

    Energy Technology Data Exchange (ETDEWEB)

    Fitterer, Miriam

    2013-02-22

    With the Large Hadron Collider (LHC) the exploration of particle physics at center of mass energies at the TeV scale has begun. To extend the discovery potential of the LHC, a major upgrade is foreseen around 2020 of the LHC itself and the LHC injectors - the chain of accelerators preparing the beam for the LHC. One of the injectors - the second one in the chain - is the Proton Synchrotron (PS) Booster. Its performance is currently limited by the space-charge effect, which is the effect of the electromagnetic field of the particle beam on itself. This effect becomes weaker with higher energy, and therefore an energy upgrade of the PS Booster to 2 GeV maximum beam energy is foreseen. As the PS Booster is with its 40 years already an old machine, the construction of a new accelerator, a Rapid Cycling Synchrotron (RCS), to replace the PS Booster has been proposed. In this thesis different options for the beam guidance in the RCS - referred to as lattice and optics - are studied, followed by a more general comparison of different lattices and optics and their performance under consideration of the space-charge effect. To further complement the LHC physics program, also the possibility of deep inelastic lepton-nucleon scattering at the LHC has been suggested, referred to as Large Hadron Electron Collider (LHeC). In this case the proton beam of the LHC collides with the electron beam, which is accelerated in a separate newly built machine. Two options are considered as electron accelerator: a new energy recovery linac - the Linac-Ring option - and the installation of an electron ring in the existing LHC tunnel - the Ring-Ring option. One of the main challenges of the Ring-Ring option is the integration of the electron ring in the current LHC tunnel. A layout, lattice and optics of the electron accelerator is developed in this thesis, which meets the requirements with regard to integration and reaches the beam parameters demanded by the particle physics experiments.

  17. CERN News: Slow ejection efficiency at the PS; Vacuum tests on the ISR; Fire in the neutrino beam-line; Prototype r.f . cavity for the Booster; Crane-bridge in ISR experimental hall; Modifications to the r.f . system at the PS

    CERN Multimedia

    1969-01-01

    CERN News: Slow ejection efficiency at the PS; Vacuum tests on the ISR; Fire in the neutrino beam-line; Prototype r.f . cavity for the Booster; Crane-bridge in ISR experimental hall; Modifications to the r.f . system at the PS

  18. Frequency of booster injections of allergoids.

    Science.gov (United States)

    Norman, P S; Creticos, P S; Marsh, D G

    1990-01-01

    In 1982, 43 ragweed-sensitive patients receiving maintenance injections of full doses of ragweed allergoid were selected for a study of the immunologic and clinical efficacy of booster injections only four times a year. These patients had participated for 2 to 7 years as part of a trial of mixes of up to four allergoids to common pollens in the mid-Atlantic area tailored to each patient's skin test sensitivity. They were divided into a group (21 patients) to receive injections every 3 months and a group (22 patients) to receive injections about every 6 weeks (eight injections per year). Patients were rerandomized after 1 year so that half of each original group switched to the alternate treatment, and this program was continued until after the ragweed season of 1985. Thirty-four patients were still under study the last year. Doses, per injection, were 100 allergoid units (1 allergoid unit equals 100 PNU) of each allergen in the mixture. Symptom scores during the 8 weeks of each of the four ragweed seasons were not significantly higher in the 3-month treated group. IgG antibody levels to Amb a I (antigen E) were followed until early 1984 and were not significantly different in the two groups, even though the 6-week treated patients received a two times higher cumulative dose per year. Rates of local and systemic reactions (percent of injections eliciting reactions) were not different in the groups, which means that the 3-month treated group had about half as many reactions by virtue of taking half as many injections.(ABSTRACT TRUNCATED AT 250 WORDS)

  19. BROOKHAVEN: Booster boost

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    After three months of intensive dedicated machine studies, Brookhaven's new Booster accelerated 5 x 10 13 protons over four cycles, about 85% of the design intensity. This was made possible by careful matching of Linac beam into the Booster and by extensive resonance stop band corrections implemented during Booster acceleration. The best single cycle injection into the AGS Alternating Gradient Synchrotron was 1.14 x 10 13 protons from the Booster. 1.05 x 10 13 protons were kept in the AGS, a 92% combined efficiency of extraction, transfer, and injection. The maximum injected 1994 shutdown period, enabling the 1994 physics run to make use of the full Booster intensity and go for the stated AGS objective of 4x10 13 protons per pulse

  20. Rf beam loading in the Brookhaven AGS with booster injection

    International Nuclear Information System (INIS)

    Zhang, S.Y.; Raka, E.; Weng, W.T.

    1992-01-01

    Multi-batch bunched beam loading during injection from the Booster to the AGS will be discussed. The full intensity beam injection to the upgraded AGS rf system with beam phase and radial feedbacks will be studied. It is shown that a beam phase feedback is necessary in order to guarantee a predictable hewn behavior after the first batch injection, otherwise the initial phase deviation for the following batch injections cannot be controlled. However, the effectiveness of the phase feedback control of the transient beam loading may be limited by an emittance blow up in the process. It is shown that a fast power amplifier feedback with a moderate gain can significantly reduce the transient effect of the bunched beam injection

  1. VME computer monitoring system of KEK-PS fast pulsed magnet currents and beam intensities

    International Nuclear Information System (INIS)

    Kawakubo, T.; Akiyama, A.; Kadokura, E.; Ishida, T.

    1992-01-01

    For beam transfer from the KEK-PS Linac to the Booster synchrotron ring and from the Booster to the Main ring, many pulse magnets have been installed. It is very important for the machine operation to monitor the firing time, rising time and peak value of the pulsed magnet currents. It is also very important for magnet tuning to obtain good injection efficiency of the Booster and the Main ring, and to observe the last circulating bunched beam in the Booster as well as the first circulating in the Main. These magnet currents and beam intensity signals are digitized by a digital oscilloscope with signal multiplexers, and then shown on a graphic display screen of the console via a VME computer. (author)

  2. Status of the 160 MeV H- Injection into the CERN PSB

    CERN Document Server

    Weterings, W; Benedetto, E; Borburgh, J; Bracco, C; Carli, C; Goddard, B; Hanke, K; Mikulec, B; Newborough, A; Noulibos, R; Tan, J

    2012-01-01

    The 160 MeV H- beam from the LINAC4 will be injected into the 4 superimposed rings of the PS Booster (PSB) with a new H- charge-exchange injection system. This entails a massive upgrade of the injection region. The hardware requirements and constraints, the performance specifications and the design of the H- injection region are described.

  3. NSLS-II booster timing system

    International Nuclear Information System (INIS)

    Cheblakov, P.; Karnaev, S.; De Long, J.

    2012-01-01

    NSLS-II light source includes the main storage ring with beam lines and injection part consisting of 200 MeV linac, a full-energy 3 GeV booster synchrotron and two transport lines. The booster timing system is a part of NSLS-II timing system which uses hardware from MicroResearch Finland: Event Generator (EVG) and Event Receivers (EVRs). The booster timing is based on the events coming from NSLS-II EVG: 'Pre-Injection', 'Injection', 'Pre-Extraction', 'Extraction'. These events are referenced to the selected RF bucket of the storage ring and correspond to the first RF bucket of the booster. EVRs provide triggers both for the injection and the extraction pulse devices. EVRs also provide the timing of booster cycle operation and generation of events for cycle-to-cycle updates of pulsed and ramping parameters, and synchronization of the booster beam instrumentation devices. This paper describes the final design of the booster timing system. The timing system functional diagrams and block diagram are presented. (authors)

  4. The Booster

    CERN Multimedia

    1972-01-01

    Where the beams from the Booster's four rings begin to recombine, before transfer to the PS. On the left are dipoles for vertical steering, and on the right is the tank containing two septum magnets which form the first combining element.

  5. Operational considerations for the PSB H- Injection System

    CERN Document Server

    Weterings, W; Borburgh, J; Carli, C; Fowler, T; Goddard, B

    2010-01-01

    For the LINAC4 project the PS Booster (PSB) injection system will be upgraded. The 160 MeV Hbeam will be distributed to the 4 superimposed PSB synchrotron rings and horizontally injected by means of an H- charge-exchange system. Operational considerations for the injection system are presented, including expected beam losses from unwanted field stripping of H- and excited H0 and foil scattering, possible injection failure cases and expected stripping foil lifetimes. Loading assumptions for the internal beam dumps are discussed together with estimates of doses on various components.

  6. 160 MeV $H^-$ Injection into the CERN PSB

    CERN Document Server

    Weterings, W; Borburgh, J; Fowler, T; Gerigk, F; Goddard, B; Hanke, K; Martini, M; Sermeus, L

    2007-01-01

    The H- beam from the proposed LINAC4 will be injected into the four existing rings of the PS Booster at 160 MeV. A substantial upgrade of the injection region is required, including the modification of the beam distribution system and the construction of a new H- injection system. This paper discusses beam dynamics and hardware requirements and presents the results of optimisation studies of the injection process for different beam characteristics and scenarios. The resulting conceptual design of the injection region is presented, together with the main hardware modifications and performance specifications.

  7. Online Measurement of the Energy Spread of Multi-Turn Beam in the Fermilab Booster at Injection

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, J. [Brown U.; Bhat, C. M. [Fermilab; Hendricks, B. S. [Fermilab

    2017-07-01

    We have developed a computer program interfaced with the ACNET environment of Fermilab accelerators to measure energy spread of the proton beam from the LINAC at an injection into the Booster. It uses a digitizing oscilloscope and provides users an ability to configure the scope settings for optimal data acquisition from a resistive wall current monitor. When the program is launched, a) a one shot timeline is generated to initiate beam injection into the Booster, b) a gap of about 40 ns is produced in the injected beam using a set of fast kickers, c) collects line charge distribution data from the wall current monitor for the first 200 μs from the injection and d) performs complete data analysis to extract full beam energy spread of the beam. The program also gives the option to store the data for offline analyses. We illustrate a case with an example. We also present results on beam energy spread as a function of beam intensity from recent measurements.

  8. Design of the New Wideband RF System for the CERN PS Booster

    CERN Document Server

    Paoluzzi, Mauro; Angoletta, Maria Elena; Arnaudon, Luca; Energico, Salvatore; Findlay, Alan; Haase, Matthias; Jaussi, Michael; Jones, Anthony; Landré, David; Molendijk, John; Quartullo, Danilo; Shaposhnikova, Elena

    2016-01-01

    For the renovation and upgrade of the CERN PS Booster (PSB) RF systems a development project was launched in 2012. The design, based on a new approach, aimed at replacing the existing tuned, narrowband RF systems with wideband, modular, solid-state driven units. A wide range of issues had to be addressed spanning from RF power production, radiation hardness of solid-state devices, active cancellation of beam-induced voltages, dedicated low-level electronics allowing multi-harmonic operation and beam stability. Following a three-year prototyping and testing campaign and two international reviews, the project endorsement came at the end of year 2015. It foresees the complete removal of present h1, h2 and h10 systems and the deployment of a new one covering all the frequency ranges from 1 MHz to 18 MHz. The four PSB rings will be equipped with 144 identical acceleration cells providing 24 kV total RF voltage per ring. This paper describes the design concepts, the retained solutions, the expected performances and...

  9. The PS complex as proton pre-injector for the LHC - design and implementation report

    International Nuclear Information System (INIS)

    Benedikt, M.; Blas, A.; Borburgh, J.

    2000-01-01

    The LHC will be supplied with protons from the pre-injector chain comprising Linac2, PS Booster and PS. These accelerators have undergone a major upgrading programme during the last five years so as to meet the stringent requirements of the LHC. This implies that many high-intensity bunches of small emittance and tight spacing (25 ns) be available at the PS extraction energy (26 GeV/c). The upgrading project involved an increase of Linac2 current, new RF systems in the PS Booster and the PS, raising the PS Booster energy from 1 to 1.4 GeV, two-batch filling of the PS, and the installation of high-resolution beam profile measurement devices. With the project entering its final phase and most of the newly installed hardware now being operational, the emphasis switches to producing the nominal LHC beam and tackling the associated beam physics problems. This report describes all the hardware changes related to the upgrading project. (orig.)

  10. Injection Bump Synchronization Study for the CERN PS

    CERN Document Server

    Serluca, Maurizio; Gilardoni, Simone; CERN. Geneva. ATS Department

    2016-01-01

    In the framework of the LHC Injector Upgrade (LIU) project the CERN PS injection kinetic energy will be upgraded from 1.4 to 2 GeV. The present injection bump is made by four bumpers in Straight Section (SS) 40, 42, 43, 44 and it will be converted in a five bumpers system to allow additional flexibility in the bump shape with a reduction of the proton losses during the bump closure. The injection section SS42 has being redesigned to accommodate a new eddy current septum which will host a new bumper magnet in the same vacuum vessel due to reduced longitudinal space availability. The synchronization and amplitude variation of the power converter of the in-vacuum bumper 42 with respect to the remaining outside vacuum bumpers 40, 41, 43, 44 can lead to orbit distortion and consequent losses during injection. In this note we present the experimental results from Machine Development (MD) studies along with simulations for the present system at 1.4 GeV to quantify the acceptable orbit distortion and the performance ...

  11. H/sup /minus// injection into the low-energy booster of the SSC

    International Nuclear Information System (INIS)

    Colton, E.P.; Thiessen, H.A.

    1988-01-01

    Protons are accumulated into the low-energy booster of the SSC by utilizing H/sup /minus// → H + conversion in a 225- μg/cm 2 carbon stripping foil. Synchronous injection is performed for 26 turns into stationary rf buckets, thereby allowing operation with variable bunch spacing. By injecting the beam offset in x and y we obtain the required rms normalized transverse emittance area of 0.75 π mm-mr. Similarly the required rms longitudinal emittance area of 1.75π /times/ 10/sup /minus/3/ eVs is obtained by injecting single linac micropulses, centered at /phi/ = 0, and dp/p = +0.12%, into each 49.9-MHz rf bucket formed with an rf voltage of 350 kV. The transverse space-charge tune shift is -0.17 for 10 10 protons/bunch accumulated at 600 MeV. 1 ref., 5 figs., 1 tab

  12. The PS Booster's ejection kicker: full house.

    CERN Multimedia

    CERN PhotoLab

    1971-01-01

    The modules of the Booster's four-storied full-aperture kicker pretty much fill their vacuum tank (front cover removed). In the original 800 MeV version, the delay-type modules were pulsed at 30 kV from a Pulse-Forming-Network (PFN), yielding a field risetime as short as 60 ns. The fieldstrength was 0.1 T at a current of 1200 A. The modules are made from steel plates and ferrite slabs. The ferrite's high initial outgassing rate presented a serious vacuum problem for a long time.

  13. Design of the Zero Gradient Synchrotron Booster-II lattice

    International Nuclear Information System (INIS)

    Crosbie, E.A.; Foss, M.H.; Khoe, T.K.; Simpson, J.D.

    1975-01-01

    A 500 MeV booster was designed at the Argonne National Laboratory to increase the beam intensity from the Zero Gradient Synchrotron (ZGS). Many turns of H - ions from the 50 MeV linac will be injected into the booster and stripped to H + so that the ring will contain the maximum useful charge in each booster pulse. Several booster pulses will be injected into the ZGS to form one ZGS pulse. This machine is now under construction. (auth)

  14. BROOKHAVEN: Booster commissioned

    Energy Technology Data Exchange (ETDEWEB)

    Bleser, Ed

    1992-03-15

    The construction and first commissioning phase of the Booster synchrotron to inject into Brookhaven's veteran Alternating Gradient Synchrotron (AGS) were completed last year. Scheduled to come into operation this year, the new Booster will extend the research capabilities AGS, and with its ability to accelerate partially stripped heavy ions will play an essential role in the chain of accelerators serving the Relativistic Heavy Ion Collider (RHIC)

  15. Revision of Booster to Storage Ring Transport Line Design and Injection Scheme for Top-Up Operation at NSRRC

    CERN Document Server

    Wang, Min-Huey; Chen, Jenny; Chen June Rong; Hsu, Kuo-Tung; Kuo, Chin-Cheng; Luo, Gwo-Huei

    2005-01-01

    In order to help the operation of constant current, the optics of booster to storage ring transport line (BTS) design is reinvestigated. The initial twiss parameters are derived by measurement. The optics of the transport line is readjusted according to the measured initial beam parameters. The design of pulse width of the injection kicker is also changed from 1.2μsecond to 2.0μsecond. The injection scheme is reviewed and the effects of the kicker error on both injected beam and stored beam are investigated and shown in this report.

  16. The Booster to AGS beam transfer fast kicker systems

    International Nuclear Information System (INIS)

    Zhang, W.; Bunicci, J.; Soukas, A.V.; Zhang, S.Y.

    1992-01-01

    The Brookhaven AGS Booster has a very successful commissioning period in June 1991. The third phase of that commissioning was a beam extraction test. The Booster extraction fast kicker (F3) deflected a 1.2 GeV proton beam from the Booster circulating orbit into the extraction septum aperture, partially down the extraction line to a temporary beam stop. Now, the Booster is committed to the AGS operations program for both heavy ion and proton beams. Thus, the Booster extraction and the corresponding AGS injection systems must operate routinely up to a pulse repetition frequency of 7.5 Hertz, and up to a beam energy of 1.5 Gev. The injection fast kicker is located in the A5 section of the AGS ring and is used to deflect the proton or heavy ion beam into its final AGS closed orbit. A distinctive feature of the AGS injection fast kicker modulators is the tail-bitting function required for proton beam injection. This enables the system to produce a fast current fall time to go along with the high current pulse amplitude with a fast rise time. The AGS injection fast kicker system has three pulse modulators, and each modulator consists of two thyratrons. The main PFN thyratrons switch on the current, and the tail bitting thyratrons are used to force the magnet current to decrease rapidly. Two digital pulse delay generators are used to align the main thyratrons and the tail bitting thyratrons respectively. The system has been tested and installed. The final commissioning of the Booster to AGS beam transfer line and injection is currently being undertaken. In this article, the system design, realization techniques and performance data will be presented

  17. Simulations Of Transverse Stacking In The NSLS-II Booster

    International Nuclear Information System (INIS)

    Fliller, R. III; Shaftan, T.

    2011-01-01

    The NSLS-II injection system consists of a 200 MeV linac and a 3 GeV booster. The linac needs to deliver 15 nC in 80 - 150 bunches to the booster every minute to achieve current stability goals in the storage ring. This is a very stringent requirement that has not been demonstrated at an operating light source. We have developed a scheme to transversely stack two bunch trains in the NSLS-II booster in order to alleviate the charge requirements on the linac. This scheme has been outlined previously. In this paper we show particle tracking simulations of the tracking scheme. We show simulations of the booster ramp with a stacked beam for a variety of lattice errors and injected beam parameters. In all cases the performance of the proposed stacking method is sufficient to reduce the required charge from the linac. For this reason the injection system of the NSLS-II booster is being designed to include this feature. The NSLS-II injection system consists of a 200 MeV linac and a 3 GeV booster. The injectors must provide 7.5nC in bunch trains 80-150 bunches long every minute for top off operation of the storage ring. Top off then requires that the linac deliver 15nC of charge once losses in the injector chain are taken into consideration. This is a very stringent requirement that has not been demonstrated at an operating light source. For this reason we have developed a method to transversely stack two bunch trains in the booster while maintaining the charge transport efficiency. This stacking scheme has been discussed previously. In this paper we show the simulations of the booster ramp with a single bunch train in the booster. Then we give a brief overview of the stacking scheme. Following, we show the results of stacking two bunch trains in the booster with varying beam emittances and train separations. The behavior of the beam through the ramp is examined showing that it is possible to stack two bunch trains in the booster.

  18. AHF Booster Tracking with SIMPSONS.

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, D. E. (David E.); Neri, F. (Filippo)

    2002-01-01

    The booster lattice for the Advanced Hydrotest Facility at Los Alamos was tracked in 3-D with the program SIMPSONS, using the full, symplectic lattice from TEAPOT, using the full set of magnet and misalignment errors, as well as full space-charge effects. The only corrections included were a rough closed-orbit correction and chromaticity correction. The lattice was tracked for an entire booster cycle, from multi-turn injection through acceleration to the top energy of 4 GeV, approximately 99,000 turns. An initial injection intensity of 4x1Ol2, injected in 25 turns, resulted in a final intensity of 3 . 2 {approx} 1 0a' {approx}t 4 GeV. Results of the tracking, including emittance growth, particle loss, and particle tune distributions are presented.

  19. AHF Booster Tracking with SIMPSONS

    International Nuclear Information System (INIS)

    Johnson, D.E.; Neri, F.

    2002-01-01

    The booster lattice for the Advanced Hydrotest Facility at Los Alamos was tracked in 3-D with the program SIMPSONS, using the full, symplectic lattice from TEAPOT, using the full set of magnet and misalignment errors, as well as full space-charge effects. The only corrections included were a rough closed-orbit correction and chromaticity correction. The lattice was tracked for an entire booster cycle, from multi-turn injection through acceleration to the top energy of 4 GeV, approximately 99,000 turns. An initial injection intensity of 4x1Ol2, injected in 25 turns, resulted in a final intensity of 3 . 2 ∼ 1 0a' ∼t 4 GeV. Results of the tracking, including emittance growth, particle loss, and particle tune distributions are presented.

  20. PS Main Control Room (partial view)

    CERN Multimedia

    1974-01-01

    Jean-Pierre Potier (turning buttons) and Bertran Frammery (telephoning) on shift. The 26 GeV Synchrotron and later also its related machines (Linacs 1,2,3; PS-Booster; LEP-Injector Linacs and Electron-Positron Accumulator; Antiproton Accumulator, Antiproton Collector, Low Energy Antiproton Ring and more recently Antiproton Decelerator) were all controlled from the PS control room situated on the Meyrin site. The SPS and LEP were controlled from a separat control centre on the Prevessin site. In 2005 all controls were transferred to the Prevessin centre.

  1. H/sup /minus// injection into the low-energy booster of the SSC [Superconducting Super Collider

    International Nuclear Information System (INIS)

    Colton, E.P.; Thiessen, H.A.

    1989-01-01

    Protons are accumulated into the low-energy booster of the SSC by utilizing H/sup /minus// → H + conversion in a 225-μg/cm 2 carbon stripping foil. Synchronous injection is performed for 26 turns into stationary rf buckets, thereby allowing operation with variable bunch spacing. By injecting the beam offset in x and y we obtain the required rms normalized transverse emittance area of 0.75 π mm-mr. Similarly the required rms longitudinal emittance area of 1.75π /times/ 10/sup /minus/3/ eVs is obtained by injecting single linac micropulses, centered at /phi/ = 0, and dp/p = +0.12%, into each 49.9-MHz rf bucket formed with an rf voltage of 350 kV. The transverse space-charge tune shift is /minus/0.17 for 10 10 protons/bunch accumulated at 600 MeV. 1 ref., 5 figs., 1 tab

  2. Magnetic Waveform Measurements of the PS Injection Kicker KFA45 and Future Emittance Growth Estimates

    CERN Document Server

    Forte, Vincenzo; Ferrero Colomo, Alvaro; CERN. Geneva. ATS Department

    2018-01-01

    In the framework of the LHC Injectors Upgrade (LIU) project [1], this document summarises the beam-based measurement of the magnetic waveform of the PS injection kicker KFA45 [2], from data collected during several Machine Development (MD) sessions in 2016 and 2017. In the first part of the document, the measurement methodology is introduced and the results presented and compared with the specification required for a clean transfer of the bunches coming from the PSB after the upgrade. These measurements represent, to date, the only way to reconstruct the magnetic waveform. In the second part, kicker magnetic waveform PSpice®[3] simulations are compared and tuned to the measurements. Finally the simulated (validated through measurements) waveforms are used to estimate the future expected emittance growth for the different PS injection schemes, both for (LIU target) LHC and fixed target beams.

  3. Design of LINAC4, A New Injector for the CERN Booster

    CERN Document Server

    Garoby, R; Lombardi, A M; Rossi, C; Vretenar, M; Gerigk, F

    2004-01-01

    A new H- linac (Linac4) is presently under study at CERN. This accelerator, based on normal conducting structures at 352 and 704 MHz, will provide a 30 mA 160 MeV H- beam to the CERN PS Booster (PSB), thus overcoming the present space-charge bottleneck at injection with a 50 MeV proton beam. Linac4 is conceived as the first stage of a future 2.2 GeV superconducting linac (SPL) and it is therefore designed for a higher duty cycle than necessary for the PSB. This paper discusses the design choices, presents the layout of the facility and illustrates the advantages for the LHC and other CERN users. The R&D and construction strategy, which mainly relies upon international collaborations, is also presented.

  4. CONCEPTUAL DESIGN OF THE NSLS-II INJECTION SYSTEM.

    Energy Technology Data Exchange (ETDEWEB)

    SHAFTAN,T.; ROSE, T.; PINAYEV, I.; HEESE, R.; BENGTSSON, J.; SKARITKA, J.; MENG, W.; OZAKI, S.; MEIER, R.; STELMACH, C.; LITVINENKO, V.; PJEROV, S.; SHARMA, S.; GANETIS, G.; HSEUH, H.C.; JOHNSON, E.D.; TSOUPAS, N.; GUO, W.; BEEBE-WANG, J.; LUCCIO, A.U.; YU, L.H.; RAPARIA, D.; WANG, D.

    2007-06-25

    We present the conceptual design of the NSLS-II injection system [1,2]. The injection system consists of a low-energy linac, booster and transport lines. We review two different injection system configurations; a booster located in the storage ring tunnel and a booster housed in a separate building. We briefly discuss main parameters and layout of the injection system components.

  5. Look into the PS Main Control Room (partial view)

    CERN Multimedia

    1974-01-01

    Jean-Pierre Potier at work. The 26 GeV Synchrotron and later also its related machines (Linacs 1,2,3; PS-Booster, LEP-Injector Linacs and Electron-Positron Accumulator; Antiproton Accumulator, Antiproton Collector, Low Energy Antiproton Ring and more recently Antiproton Decelerator) were all controlled from the PS control room situated at the Meyrin site. The SPS and LEP were controlled from a separat control centre on the Prevessin site. In 2005 all controls were transferred to the Prevessin centre.

  6. Multiple bunch-splitting in the PS results and plans

    CERN Document Server

    Garoby, R

    2001-01-01

    The nominal longitudinal characteristics of the PS proton beam for the LHC were attained during the year 2000, using a sequence of triple- and double-splittings to divide each PS Booster (PSB) bunch into 12. This method minimizes longitudinal emittance blow-up and preserves a gap, free of particles, in the bunch train. Some of the ideas for alternative bunch trains have also been tested. The performance achieved is described and the sources of limitations are discussed together with the foreseen improvements.

  7. New safety training for access to the PS complex areas

    CERN Multimedia

    2012-01-01

    Since 10/08/2012, a new course dedicated to the specific radiological risks in the accelerators of the PS complex has been available on SIR (https://sir.cern.ch/). This course complements the general classroom-based Radiation Safety training. Successful completion of the course will be obligatory and verified by the access system as from 01/11/2012 for access to the following accelerator areas: LINAC2, BOOSTER, PS and TT2. Information and reminder e-mails will be sent to all persons currently authorized to access the accelerators of the PS complex. For questions please contact the HSE unit and in particular, the Radiation Protection Group (+41227672504 or safety-rp-ps-complex@cern.ch).

  8. Design of Injection and Extraction Systems with Optimisation of Lattice and Layout for the CERN PS2 Synchrotron

    CERN Document Server

    Bartmann, W

    2009-01-01

    The CERN Proton Synchrotron PS2 is one of the foreseen accelerators for the LHC injector upgrade. This upgrade aims first at increasing the instantaneous luminosity of LHC and second at providing a reliable beam for the CERN accelerator complex. From this aspect, the main characteristics of the PS2 are high reliability for high intensity beams. The goal of this thesis was the design of the machine’s lattice and injection/extraction systems meeting the constraints coming mainly from the LHC beam type but also from beam requirements of experiments at PS2 and the SPS. In the design, the given energy range together with filling schemes for different beam types and RF cogging were first used to define the circumference of the machine. Estimates on the space requirements of injection/extraction systems were made in order to divide the total machine length between arc and long straight section. Existing tunnels for transfer lines together with the minimisation of the total transfer line length favoured a race trac...

  9. Studies on Transverse Painting for H- Injection into the PSB

    CERN Document Server

    Bracco, C; Fowler, T; Goddard, B; Grawer, G; Lallement, J B; Martini, M; Weterings, W

    2011-01-01

    Linac4 will inject 160 MeV H- ions into the CERN PS Booster (PSB). This will allow to reduce space charge effects and increase beam intensity but will require a substantial upgrade of the injection region. The PSB has to provide beam to several users with different requirements in terms of beam intensity and emittance. Four kicker magnets (KSW) will be used to accomplish painting in the horizontal phase space to match the injected beams to the required emittances. Multiple linear functions, with varying slopes for each user, have been defined for the KSW generators waveforms according to detailed beam dynamic studies for all target intensities and emittances. Preliminary studies have been carried out to evaluate how to obtain the required vertical emittance and the option of a transverse painting, also in the vertical plane, is explored.

  10. Tracking study of hadron collider boosters

    Energy Technology Data Exchange (ETDEWEB)

    Machida, S.; Bourianoff, G.; Huang, Y.; Mahale, N.

    1992-07-01

    A simulation code SIMPSONS (previously called 6D-TEASE T) of single- and multi-particle tracking has been developed for proton synchrotrons. The 6D phase space coordinates are calculated each time step including acceleration with an arbitrary ramping curve by integration of the rf phase. Space-charge effects are modelled by means of the Particle In Cell (PIC) method. We observed the transverse emittance growth around the injection energy of the Low Energy Booster (LEB) of the Superconducting Super Collider (SSC) with and without second harmonic rf cavities which reduce peak line density. We also employed the code to see the possible transverse emittance deterioration around the transition energy in the Medium Energy Booster (MEB) and to estimate the emittance dilution due to an injection error of the MEB.

  11. LHC Report: imaginative injectors

    CERN Multimedia

    Pierre Freyermuth for the LHC team

    2016-01-01

    A new bunch injection scheme from the PS to the SPS allowed the LHC to achieve a new peak luminosity record.   Figure 1: PSB multi-turn injection principle: to vary the parameters during injection with the aim of putting the newly injected beam in a different region of the transverse phase-space plan. The LHC relies on the injector complex to deliver beam with well-defined bunch populations and the necessary transverse and longitudinal characteristics – all of which fold directly into luminosity performance. There are several processes taking place in the PS Booster (PSB) and the Proton Synchrotron (PS) acting on the beam structure in order to obtain the LHC beam characteristics. Two processes are mainly responsible for the beam brightness: the PSB multi-turn injection and the PS radio-frequency (RF) gymnastics. The total number of protons in a bunch and the transverse emittances are mostly determined by the multi-turn Booster injection, while the number of bunches and their time spacin...

  12. Automated tuning of the advanced photon source booster synchrotron

    International Nuclear Information System (INIS)

    Biedron, S.G.; Milton, S.V.

    1997-01-01

    The acceleration cycle of the Advanced Photon Source (APS) booster synchrotron is completed within 223 ms and is repeated at 2 Hz. Unless properly corrected, transverse and longitudinal injection errors can lead to inefficient booster performance. In order to simplify daily operation, automated tuning methods have been developed. Through the use of beam position monitor (BPM) reading, transfer line corrector magnets, magnet ramp timing, and empirically determined response functions, the injection process is optimized by correcting the first turn trajectory to the measured closed orbit. These tuning algorithms and their implementation are described here along with an evaluation of their performance

  13. Synchronization of the Zero Gradient Synchrotron (ZGS) and the fast-cycling booster II injector

    International Nuclear Information System (INIS)

    Rauchas, A.V.

    1977-01-01

    The planned method of booster injection into the ZGS requires the stacking of two booster beam bunches into the radial betatron phase space of the ZGS and necessitates precise synchronization of the two accelerators during the injection period. The requirement of maintaining independent radio-frequency (rf) steering control does not allow the frequencies of both accelerators to be locked. A synchronizer was developed which detects a coincidence zero crossing of the two rf's, anticipates the next coincidence, and at that time, generates trigger pulses for the booster extraction and ZGS injection systems. It also maintains control of the sequence in which the total phase space area of the ZGS is loaded. Synchronizer accuracy is obtained by using high speed digital logic circuits. Design considerations and system operation are discussed

  14. New Pulsed Orbit Bump Magnets for the Fermilab Booster Synchrotron

    CERN Document Server

    Lackey, James; John, Carson; Kashikhin, Vladimir; Makarov, Alexander; Prebys, Eric

    2005-01-01

    The beam from the Fermilab Linac is injected onto a bump in the closed orbit of the Booster Synchrotron where a carbon foil strips the electrons from the Linac’s negative ion hydrogen beam. Although the Booster itself runs at 15Hz, heat dissipation in the orbit bump magnets has been one limitation to the fraction of the cycles that can be used for beam. New, 0.28T pulsed window frame dipole magnets have been constructed that will fit into the same space as the old ones, run at the full repetition rate of the Booster, and provide a larger bump to allow a cleaner injection orbit. The new magnets use a high saturation flux density Ni-Zn ferrite in the yoke rather than laminated steel. The presented magnetic design includes two and three dimensional magnetic field calculations with eddy currents and ferrite nonlinear effects.

  15. Energy-efficient operation of a booster RF system for Taiwan light source operated in top-up mode

    International Nuclear Information System (INIS)

    Yeh, Meng-Shu; Wang, Chaoen; Chang, Lung-Hai; Chung, Fu-Tsai; Yu, Tsung-Chi; Lin, Ming-Chyuan; Chen, Ling-Jhen; Yang, Tz-Te; Chang, Mei-Hsia; Lin, Yu-Han; Tsai, Ming-Hsun; Lo, Chih-Hung; Liu, Zong-Kai

    2015-01-01

    Contemporary light sources operate in a top-up mode to maintain their photon intensity quasi-constant so as to improve significantly the thermal stability of the photon beam and to maximize ultimately the average photon flux at a designed maximum operational beam current. Operating in a top-up mode requires frequent beam injection from the synchrotron booster to the storage ring of the light source, but the injection intervals occupy only a tiny portion of the operational time of the integrated machine. To maintain a high operational reliability, the booster RF system practically operates necessarily under injection conditions around the clock and consumes full electric power whether during top-up injection or not. How to decrease the power consumption of the booster RF system during its stand-by time but not to sacrifice the reliability and availability of the RF system is obviously of fundamental interest for routine operation of the light source in a top-up mode. Here, an energy-efficient operation of a booster RF system adaptive to top-up operation of a light source is proposed that has been developed, realized and integrated into the booster RF system of the Taiwan Light Source (TLS), and routinely operated since the end of year 2008. The klystron cathode current and RF gap voltage of the booster's accelerating RF cavity are both periodically modulated to adapt the injection rhythm during top-up operation, which results in decreased consumption of electric power of the booster RF system by more than 78%. The impact on the reliability and availability of the booster RF system has been carefully monitored during the past five operational years, delivering more than 5000 h scheduled user beam time per year. The booster RF system retains its excellent reliability and availability as previously. Neither a decrease of the service time nor an induced reliability issue from the klystron or any high-power high-voltage component of the transmitter has been

  16. Design and status of the AGS booster accelerator

    International Nuclear Information System (INIS)

    Forsyth, E.B.; Lee, Y.Y.

    1987-01-01

    Comments are given on some areas of the design considered for the AGS Booster Accelerator, including lattice design, energy and repetition rate, injection, radio frequency system, and the vacuum system. The current status is then briefly described

  17. Design and status of the AGS booster accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, E.B.; Lee, Y.Y.

    1987-01-01

    Comments are given on some areas of the design considered for the AGS Booster Accelerator, including lattice design, energy and repetition rate, injection, radio frequency system, and the vacuum system. The current status is then briefly described. (LEW)

  18. Design study of CEPC Alternating Magnetic Field Booster

    CERN Document Server

    Bian, T; Cai, Y; Cui, X; Gao, J; Koratzinos, M; Su, F; Wang, D; Wang, Y; Xiao, M; Zhang, C

    2017-01-01

    The CEPC is a next generation circular e+e- collider proposed by China. The design of the full energy booster ring of the CEPC is especially challenging. The ejected beam energy is 120 GeV, but that of the injected beam is only 6 GeV. In a conventional approach, the low magnetic field of the main dipole magnets creates problems. We propose operating the booster ring as a large wiggler at low beam energies and as a normal ring at high energies to avoid the problem of very low dipole magnet fields.

  19. Injection septa position and angle optimisation in view of the 2 GeV liu upgrade of the CERN PS

    CERN Document Server

    Serluca, HM; Forte, V; Fraser, M; Sterbini, G

    2017-01-01

    In the framework of the LHC Injector Upgrade (LIU)project the CERN PS injection kinetic energy will be up-graded from 1.4 to 2 GeV. The injection equipment, whichis already operating close to its limit, is being redesigned tocope with 30% increase in the beam rigidity. In this paper wepresent the experimental results from Machine Development(MD) studies on the present septum to explore its operationalhardware limits with respect to aperture restrictions, beamlosses and kick strengths in view of the LIU upgrade

  20. Rapid cycling superconducting booster synchrotron

    International Nuclear Information System (INIS)

    Dinev, D.; Agapov, N.; Butenko, A.

    2001-01-01

    The existing set of Nuclotron heavy ion sources, such as duoplasmatron, polarized deuteron, laser and electron beam ion sources permits to have ion beams over a wide range of masses. The main problem for us now is to gain high intensity of accelerator particles. It can be solved by means of multiturn injection of the low current beams into the booster, acceleration up to the intermediate energies, stripping and transferring into the main ring. A design study of this accelerator - the 250 MeV/Amu Nuclotron booster synchrotron at 1 Hz repetition rate and circumference of 84 m, has been completed. The lattice dipole and quadrupole magnets have an iron yoke coils, made of hollow superconductor, are cooled by two-phase Helium flow, as well as the Nuclotron magnets. (authors)

  1. A Computer Program to Measure the Energy Spread of Multi-turn Beam in the Fermilab Booster at Injection

    Science.gov (United States)

    Nelson, Jovan; Bhat, Chandrashekhara; Hendricks, Brian

    2016-03-01

    We have developed a computer program interfaced with the ACNET environment for Fermilab accelerators in order to measure the energy spread of the injected proton beam from the LINAC, at the energy of 400 MeV. This program allows the user to configure a digitizing oscilloscope and timing devices to optimize data acquisition from a resistive wall current monitor. When the program is launched, it secures control of the oscilloscope and then generates a ``one-shot'' timeline which initiates injection into the Booster. Once this is complete, a kicker is set to create a notch in the beam and the line charge distribution data is collected by the oscilloscope. The program then analyzes this data in order to obtain notch width, beam revolution period, and beam energy spread. This allows the program to be a possible useful diagnostic tool for the beginning of the acceleration cycle for the proton beam. Thank you to the SIST program at Fermilab.

  2. Relativistic heavy ions from the BNL [Brookhaven National Laboratory] booster medical research and technological applications

    International Nuclear Information System (INIS)

    Thieberger, P.

    1990-05-01

    The BNL Booster, now nearing completion, was designed to inject protons and heavy ions into the Alternating Gradient Synchrotron (AGS) for further acceleration. In the future, ion beams from the AGS will in turn be further accelerated in the Relativistic Heavy Ion Collider (RHIC). Given the wide range of ion masses, energies and beam intensities the Booster will generate, other important applications should be considered. Dedicated use of the Booster for such applications may be possible during limited periods. However shared use would be preferable from the points of view of availability, affordability and efficiency. While heavy ions of a given isotope are injected into the AGS, the same or other ion species from the Booster could be simultaneously delivered to a new irradiation area for treatment of patients, testing of electronic devices or other applications and research. To generate two different beam species, ion sources on both Tandem accelerators would be used; one for AGS injection and the other one for a time-sharing application. Since the beam transport from the Tandems to the Booster can not be rapidly adjusted, it will be necessary to select beams of identical magnetic rigidity. The present study was performed to determine to what extent this compatibility requirement imposes limitations on the available ion species, energies and/or intensities

  3. Simulation of proton RF capture in the AGS Booster

    International Nuclear Information System (INIS)

    Khiari, F.Z.; Luccio, A.U.; Weng, W.T.

    1988-01-01

    RF capture of the proton beam in the AGS Booster has been simulated with the longitudinal phase-space tracking code ESME. Results show that a capture in excess of 95% can be achieved with multiturn injection of a chopped beam

  4. Repeated intraperitoneal injections of liposomes containing phosphatidic acid and cardiolipin reduce amyloid-β levels in APP/PS1 transgenic mice

    DEFF Research Database (Denmark)

    Ordóñez-Gutiérrez, Lara; Re, Francesca; Bereczki, Erika

    2015-01-01

    , it was hypothesized that shifting this equilibrium towards the blood by enhancing peripheral clearance might reduce Aβ levels in the brain: the 'sink effect'. We tested this hypothesis by intraperitoneally injecting APP/PS1 transgenic mice with small unilamellar vesicles containing either phosphatidic acid...... Aβ may be therapeutically relevant in AD. FROM THE CLINICAL EDITOR: Intraperitoneal injection of small unilamellar vesicles containing phosphatidic acid or cardiolipin significantly reduced the amount of amyloid-beta (Aß) peptide in the plasma in a rodent model. Brain levels of Aß were also affected...

  5. Antiproton Production beam and Reverse Injection System

    Energy Technology Data Exchange (ETDEWEB)

    Chadwick, G.

    1981-08-16

    The objectives of this project are two fold: (1) To extract high energy protons from the Main Ring (MR) and target them to produce antiprotons which are subsequently captured in the existing Booster accelerator; and (2) to provide a channel for injecting either protons or antiprotons into the MR from the booster in a direction opposite to that of the normal proton acceleration as colliding beams can be created. The present design, therefore, is in support of two separate larger projects, viz., the collisions of protons in the Tevatron (normal circulation direction) with 'reverse injected' protons in the MR, and the collision of normal direction protons with reverse injected antiprotons either in the MR or in the Tevatron. Figure 1 shows the layout of the project area. It spans the shortest distance between possible injection/ejection points in the existing accelerator structures, hence minimizing costs. The tunnel will lie underground at the level of the MR and booster.

  6. FNAL Booster intensity, extraction, and synchronization control for collider operation

    International Nuclear Information System (INIS)

    Ducar, R.J.; Lackey, J.R.; Tawzer, S.R.

    1987-03-01

    Booster operation for collider physics is considerably different than for fixed target operation. Various scenarios for collider physics, machine studies, and P-Bar targeting may require that the intensity vary from 5E10 PPP to 3E12 PPP at a 15 Hertz machine cycle rate. In addition to the normal Booster single turn extraction mode, collider operations require that the Booster inject into the Main Ring a small number of beam bunches for coalescing into a single high intensity bunch. These bunches must be synchronized such that the center bunch arrives in the RF bucket which corresponds to the zero phase of the coalescing cavity. The system implemented has the ability to deliver a precise fraction of the available 84 Booster beam bunches to Main Ring or to the P-Bar Debuncher via the newly installed AP-4 beam line for tune-up and studies. It is required that all of the various intensity and extraction scenarios be accommodated with minimal operator intervention

  7. Observation and correction of resonance stopbands in the AGS Booster

    International Nuclear Information System (INIS)

    Gardner, C.; Shoji, Y.; Ahrens, L.; Glenn, J.W.; Lee, Y.Y.; Roser, T.; Soukas, A.; van Asselt, W.; Weng, W.T.

    1993-01-01

    At the design intensity of 1.5 x 10 13 ppp, the space charge tune shift in the AGS Booster at injection has been estimated to be about 0.35. Therefore, the beam is spread over may lower order resonance lines and the stopbands have to be corrected to minimize the amplitude growth by proper compensation of the driving harmonics resulting from random errors. The observation and correction of second and third order resonance stopbands in the AGS Booster, and the establishment of a favorable operating point at high intensity are discussed

  8. A&T Sector Note on the PS transverse feedback

    CERN Document Server

    Coly, Marcel; Blas, Alfred; Sterbini, Guido; CERN. Geneva. ATS Department

    2017-01-01

    In a particle accelerator, several contributions can degrade the beam quality and particularly the beam transverse emittance. In this document we will describe a system used in the CERN Proton Synchrotron (PS) to cope with the injection steering errors and the transverse instabilities: the PS transverse feedback (PS TFB). As time progresses, this system is also being used for other purpose, to increase in a controlled way the beam transverse emittance and to excite the beam for the Multi-Turn-Extraction (MTE). In 2016, it has been successfully used on some operational beams to damp injection oscillations. This allowed to test the reliability of the system for its operational deployment. A piquet service is available in case of problem.

  9. Hollow bunches production

    CERN Document Server

    Hancock, S

    2017-01-01

    Hollow bunches address the issue of high-brightnessbeams suffering from transverse emittance growth in a strongspace charge regime. During the Proton Synchrotron (PS)injection plateau, the negative space charge tune shift canpush the beam onto theQy=6integer resonance. Modify-ing the longitudinal bunch profile in order to reduce the peakline charge density alleviates the detrimental impact of spacecharge. To this end we first produce longitudinally hollowphase space distributions in the PS Booster by exciting aparametric resonance with the phase loop feedback system.These inherently flat bunches are then transferred to the PS,where the beam becomes less prone to the emittance growthcaused by the integer resonance.During the late 2016 machine development sessions inthe PS Booster we profited from solved issues from 2015and managed to reliably extract hollow bunches of1.3eVsmatched longitudinal area. Furthermore, first results to cre-ate hollow bunches with larger longitudinal emittances to-wards the LHC Inject...

  10. Overview of the CERN Linac4 beam instrumentation

    CERN Document Server

    Roncarolo, F; Bravin, E; Dehning, B; Duraffourg, M; Gerard, D; Holzer, E B; Lenardon, F; Focker, G; Raich, U; Soby, L; Sordet, M; Tan, J; Tranquille, G; Vuitton, C; Zamantzas, C; Cheymol, B

    2010-01-01

    The CERN LINAC4 will represent the first upgrade of the LHC injection chain, by accelerating H- ions from 45 KeV to 160 MeV for charge-exchange injection into the PS Booster. In order to provide its safe and efficient commissioning and operation, a wide variety of beam diagnostics devices has been designed for installation at convenient locations all over the accelerator length and in the transfer line to the PS Booster. This paper gives an overview of all instrumentation devices, including those to measure beam position, transverse and longitudinal profile, beam current and beam loss. The well advanced status of the system design and the main instrument features are discussed

  11. Analysis of resonance-driving imperfections in the AGS Booster

    International Nuclear Information System (INIS)

    Gardner, C.; Shoji, Y.; Danby, G.; Glenn, J.W.; Jackson, G.J.; Soukas, A.; van Asselt, W.; Whalen, C.

    1994-01-01

    At the design intensity of 1.5 x 10 13 ppp, the space charge tune shift in the AGS Booster at injection has been estimated to be about 0.35. The beam tunes are therefore spread over many lower order resonance lines and the associated stopbands must be corrected in order to minimize the amplitude growth due to resonance excitation. This requires proper compensation of the resonance-driving harmonics which result from random magnetic field errors. The observation and correction of second and third order resonance stopbands in the AGS Booster is reviewed, and an analysis of magnetic field imperfections based on the required corrections is given

  12. Data acquisition and control of the Zero Gradient Synchrotron 500 MeV booster synchrotron

    International Nuclear Information System (INIS)

    Timm, R.E.; Forrestal, J.; Hogrefe, R.; Voss, D.

    1977-01-01

    A data acquisition and control philosophy for the Zero Gradient Synchrotron (ZGS) 500 MeV booster has involved a top down design incorporating all of the systems comprising the booster. Consideration of operational complexity was necessary because the booster is to be used simultaneously for ZGS injection, and solid state physics studies. Existing software and hardware capabilities of the ZGS computer were considered. The resulting data acquisition and control system is based on a mix of sequential logic and a minicomputer. Hardware considerations were based on a ten year life expectancy of the booster. Due to time, budget, and manpower constraints, the incorporation of the total design has been divided into three phases of implementation. The first phase is covered and the remaining phases are outlined

  13. Magnet power supply system for the ALS storage ring and booster

    International Nuclear Information System (INIS)

    Jackson, L.T.; Luchini, K.; Lutz, I.

    1993-05-01

    The Magnet Power Supply System is described by specification, design, hardware, and operating experience. A unique system for the one Hz, 1.5 GeV Booster, where the wideband QF and QD power supplies track the dipole current to within 0.1% at injection will be detailed. AC distribution system considerations related to inverting the stored energy of the booster magnet back into power grid will be discussed. The rational for linear correctors and individual quad supplies (225 total units) will be placed within the context of the storage-ring requirements

  14. The first acceleration test of polarized protons in KEK PS

    International Nuclear Information System (INIS)

    Hiramatsu, Shigenori; Sato, Hikaru; Toyama, Takeshi

    1984-03-01

    The outline of the polarized proton acceleration project at KEK and the results of the first acceleration test are described. Depolarization in the 500 MeV booster synchrotron was investigated as the first step of this program. The beam polarization was measured in the 20 MeV beam transport line from the linac to the booster and in the main ring at the injection energy. About 40 % of the linac beam polarization was kept in the main ring. This acceleration test encouraged us to proceed with this program. (author)

  15. Possibility of a higher PSB to PS transfer energy

    CERN Document Server

    Hanke, K; Blas, A; Borburgh, J; Bozzini, D; Buzio, M; Capatina, O; Carli, C; Dobers, T; Fernandez, L; Findlay, A; Folch, R; Gilardoni, S; Gilbert, N; Hermanns, T; Mahner, E; Mikulec, B; Newborough, A; Nonis, M; Olek, S; Paoluzzi, M; Pittet, S; Ruehl, I; Rumolo, G; Steerenberg, R; Tan, J; Tommasini, D; Weterings, W; Widorski, M; Shaposhnikova, E

    2011-01-01

    Following the Chamonix 2010 workshop a task force has been set up to study the feasibility and the impact of an energy upgrade of the PS Booster from the present 1.4 GeV to about 2 GeV. The working group has confirmed the feasibility of such an upgrade, and analysed in detail the impact on the accelerator hardware along with a cost estimate and a tentative planning. The outcome of the task force will be summarized, with particular emphasis on the remaining limitations, risks and uncertainties.

  16. submitter Direct Drive and Eddy Current Septa Magnet Designs for CERN's PSB Extraction at 2 GeV

    CERN Document Server

    Szoke, Z; Balhan, B; Baud, C; Borburgh, J; Hourican, M; Masson, T; Prost, A

    2016-01-01

    In the framework of the LIU project, new septa magnets have been designed between CERN's PS booster (PSB) extraction and PS injection. The upgraded devices are to deal with the increased beam energy from 1.4 to 2 GeV at extraction of the PSB. The direct drive recombination septa in the PSB transfer line to the PS and the eddy current PS injection septum together with a bumper at injection have been investigated using finite-element software. For the recombination magnets, an increase in magnet length is sufficient to obtain the required deflection; however, for the PS injection elements, a more novel solution is necessary to also achieve increased robustness to extend the expected lifetime of the pulsed device. The injection septum will share the same vacuum vessel with an injection bumper, and both magnets will be located adjacent to each other. The new PS injection magnet will be the first septum operated at CERN based on eddy current technology. The magnetic modeling of the devices, the comparison of the p...

  17. Direct Drive and Eddy Current Septa Magnet Designs for CERN’s PSB Extraction at 2 GeV

    CERN Multimedia

    Szoke, Zsolt; Balhan, Bruno; Baud, Cedric; Borburgh, Jan; Hourican, Michael; Masson, Thierry; Prost, Antoine

    2015-01-01

    In the framework of the LIU project, new septa magnets have been designed between CERN’s PS Booster (PSB) extraction and PS injection. The upgraded devices are to deal with the increased beam energy from 1.4 GeV to 2 GeV at extraction of the PSB. The direct drive recombination septa in the PSB transfer line to the PS, the eddy current PS injection septum together with a bumper at injection have been investigated using finite element software. For the recombination magnets an increase in magnet length is sufficient to obtain the required deflection; however, for the PS injection elements a more novel solution is necessary to also achieve increased robustness to extend the expected lifetime of the pulsed device. The injection septum will share the same vacuum vessel with an injection bumper and both magnets will be located adjacent to each other. The new PS injection magnet will be the first septum operated at CERN based on eddy current technology. The magnetic modelling of the devices, the comparison of the ...

  18. Transfer line from the PSB to the PS (recombination)

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    After sequential ejection of 5 bunches from each of the 4 rings of the Booster (originally 800 MeV, now 1.4 GeV), the 4 batches are brought to the same vertical level, so as to form a string of 20 bunches, filling the circumference of the PS. This vertical "recombination" is performed in the transfer line, using vertical bending magnets, septa and kickers. Here we see the section where the beam from ring 4 (the top one) is brought down to the level of ring 3, and the beam from ring 1 up to the level of ring 2. Further downstream (to the right, outside this picture), level 2 is brought up to level 3, identical to that of the PS. After this original recombination scheme, other ways of combining the 4 beams, vertically and/or longitudinally, were developed and used in operation.

  19. Gamma Transition Jump for PS2

    CERN Document Server

    Bartmann, W; Métral, E; Möhl, D; Peggs, S

    2008-01-01

    The PS2, which is proposed as a replacement for the existing ~50-year old PS accelerator, is presently considered to be a normal conducting synchrotron with an injection kinetic energy of 4 GeV and a maximum energy of 50 GeV. One of the possible lattices (FODO option) foresees crossing of transition energy near 10 GeV. Since the phase-slip-factor $\\eta$ becomes very small near transition energy, many intensity dependent effects can take place in both longitudinal and transverse planes. The aim of the present paper is on the one hand to scale the gamma transition jump, used since 1973 in the PS, to the projected PS2 and on the other hand based on these results the analysis of the implementation and feasibility of a gamma transition jump scheme in a conventional FODO lattice.

  20. Charge exchange studies with Gold ions at the Brookhaven Booster and AGS

    International Nuclear Information System (INIS)

    Ahrens, L.A.; Hseuh, H.C.; Roser, T.

    1994-01-01

    Efficient acceleration of Gold ions to ll GeV/nucleon places strong constraints on the vacuum and also on the choice of thickness and material of the necessary stripping foils. Results of a number of detailed experimental studies performed with the Gold beam at the Brookhaven Booster and AGS to determine the relevant electron stripping and pick-up probabilities are presented. Of particular interest is the lifetime of the relatively low energy, partially stripped Gold beam in the Booster and the stripping efficiency to Helium-like AU +77 for injection into the AGS

  1. Septum magnets for booster ring

    International Nuclear Information System (INIS)

    Mishra, R.K.; Mhaskar, S.P.; Ramamurthi, S.S.

    1991-01-01

    Synchrotron radiation source facility in CAT will employ one septum magnet for the injection of 20 MeV electron beam from the microtron and another septum magnet for the extraction of 700 MeV electron beam from the booster synchrotron. The septum is a boundary that combines or separates the beam by providing the different deflecting fields on either side of this boundary. In this magnet, septum sheet must be as thin as possible to reduce the beam losses and fringing field must be very low. Two septum magnets have been designed, one has 2 mm thick septum sheet for the injection of beam and another one has 3 mm thick septum sheet for the extraction of beam. The field strength of injection and extraction septum magnets, is 0.15 T and 0.88 T respectively. The fringing field near the septum sheet is only 10 G and 30 G for the injection and extraction magnet respectively. The field simulation has been done by computer code PANDIRA. The field homogeneity within gap is ± 0.1%. The design details are discussed in this paper. (author). 4 refs., 1 tab., 1 fig

  2. A rookie's guide to Booster operations. Booster technical note no. 231

    Energy Technology Data Exchange (ETDEWEB)

    Zeno, K. [Brookhaven National Lab. (BNL), Upton, NY (United States). Alternating Gradient Synchrotron Dept.

    1998-09-29

    The purpose of the Booster is to act as an injector for the AGS. It accelerates both protons and other ions. Proton acceleration is distinguished from the acceleration of other ions for several reasons. First, the experimental physics associated with protons, called High Energy Physics is different than that associated with other Ions, called Heavy Ion Physics. From the machine perspective, the process of injection of so called Heavy Ions (ions which are not protons), is distinctly different, from that of protons. A different preinjector, or injector for the Booster, is used for each case. For Protons, a 200 MeV Linear accelerator (The Linac) serves as a preinjector; for Heavy Ions, the Tandem Van De Graaf (The Tandem) is the preinjector. An attribute of the circulating beam which determines to a large degree what problems and what type of machine setup is involved is the beam intensity. The author's focus in this guide is on trying to convey the knowledge and experience involved in the operation of the Booster. Many of the problems encountered can be traced back to equipment failures, often power supplies. Although diagnostics are used, there can also be issues with the controls system itself. Problems with the controls system and prevent fixing or even finding a problem with a machine. The issue of improving a machines' performance can often involve trial and error and observations. The hard part is finding the relationships between things in the day to day operation of the machine. Abstractions about physics, information about controls and instrumentation, and purely empirical observations of how the machine behaves are all part of it.

  3. Interleaving of beam lines inside the PS tunnel

    CERN Multimedia

    1983-01-01

    View against the direction of the proton beams. The PS ring (section 26) is on the left. The injection tunnel for LEAR leaving from here has increased the trafic in this already busy area where the two Linacs and the transfer tunnel leading to the SPS, ISR and AA join the PS ring (cf. photo 7802260, 7802261, Annual Report 1981, p. 89, fig. 12).

  4. Beam Based RF Voltage Measurements and Longitudinal Beam Tomography at the Fermilab Booster

    Energy Technology Data Exchange (ETDEWEB)

    Bhat, C. M. [Fermilab; Bhat, S. [Fermilab

    2017-10-19

    Increasing proton beam power on neutrino production targets is one of the major goals of the Fermilab long term accelerator programs. In this effort, the Fermilab 8 GeV Booster synchrotron plays a critical role for at least the next two decades. Therefore, understanding the Booster in great detail is important as we continue to improve its performance. For example, it is important to know accurately the available RF power in the Booster by carrying out beam-based measurements in order to specify the needed upgrades to the Booster RF system. Since the Booster magnetic field is changing continuously measuring/calibrating the RF voltage is not a trivial task. Here, we present a beam based method for the RF voltage measurements. Data analysis is carried out using computer programs developed in Python and MATLAB. The method presented here is applicable to any RCS which do not have flat-bottom and flat-top in the acceleration magnetic ramps. We have also carried out longitudinal beam tomography at injection and extraction energies with the data used for RF voltage measurements. Beam based RF voltage measurements and beam tomography were never done before for the Fermilab Booster. The results from these investigations will be very useful in future intensity upgrades.

  5. User control of the proton beam injection trajectories into the AGS Booster

    International Nuclear Information System (INIS)

    D'Ottavio, T.; Kponou, A.; Luccio, A.; Alessi, J.G.; Reece, R.K.; Skelly, J.

    1991-01-01

    The 1.5 GeV (proton) Booster Synchrotron nearing completion at the AGS will get its 200 MeV beam from the linac, via a 34.9 m long linac-to-Booster transport line, LTB. LTB branches off from the existing linac-to-AGS transport line, HEBT, approximately 18.4 m downstream from the linac. A schematic layout of LTB is shown in the bottom part of Fig. 1. The four dipoles, DH2 through DH5, which are identical and are operated in series, provide a 126 degrees bend in the line. We have employed three strategies for implementing control of the trajectory, namely: (1) a global correction (2) a local correction (3) a zeroing correction. These, as well as their implementation, will be discussed. Operating experience obtained from early commissioning runs will be given. The hardware used to implement the correction schemes are the beam position monitors, BPMxxx, orbit correctors, DHxxx and DVxxx, and multiwire profile monitors, MWxxx. The quads are QHxxx and QVxxx. 3 refs., 3 figs

  6. The low energy booster project status

    International Nuclear Information System (INIS)

    Tuttle, G.W.

    1993-05-01

    In order to achieve the required injection momentum, the Superconducting Super Collider (SSC) has an accelerator chain comprised of a Linear Accelerator and three synchrotrons. The Low Energy Booster (LEB) is the first synchrotron in this chain. The LEB project has made significant progress in the development of major subsystems and conventional construction. This paper briefly reviews the performance requirements of the LEB and describes significant achievements in each of the major subsystem areas. Highlighted among these achievements are the LEB foreign collaborations with the Budker Institute of Nuclear Physics (BINP) located in Novosibirsk, Russia

  7. H- charge exchange injection systems

    International Nuclear Information System (INIS)

    Ankenbrandt, C.; Curtis, C.; Hojvat, C.; Johnson, R.P.; Owen, C.; Schmidt, C.; Teng, L.; Webber, R.C.

    1980-01-01

    The techniques and components required for injection of protons into cyclic accelerators by means of H - charge exchange processes are reviewed, with emphasis on the experience at Fermilab. The advantages of the technique are described. The design and performance of the system of injection of H - ions into the Fermilab Booster are detailed. (Auth.)

  8. New low-level rf system for the Fermilab Booster synchrotron

    International Nuclear Information System (INIS)

    Kerns, C.; Crisp, J.; Kerns, Q.; Miller, H.

    1987-03-01

    This paper describes the Booster low-level rf system that was constructed to meet these recently added requirements: (1) synthesizer controlled capture frequency at injection, (2) very low-phase noise over the machine cycle, (3) smooth phase-lock of beam to an external reference frequency and (4) ability to accelerate either a full turn or partial turn of beam

  9. A Linac afterburner to supercharge the Fermilab booster

    International Nuclear Information System (INIS)

    Ankenbrandt M, Charles email = popovic@fnal.gov

    2002-01-01

    A Linac Afterburner is proposed to raise the energy of the beam injected into the Femrilab Booster from 400 MeV to about 600 MeV, thereby alleviating the longitudinal and transverse space-charge effects at low energy that currently limit its performance. The primary motivation is to increase the integrated luminosity of the Tevatron Collider in Run II, but other future programs would also recap substantial benefits. The estimated cost is $23M

  10. Antibody against progesterone in local rabbit following low dose of progesterone injection

    Directory of Open Access Journals (Sweden)

    Suyadi Suyadi

    2012-03-01

    Full Text Available ABSTRACT: Antibody against progesgerone was produced from serum of local rabbit following low dose of progesterone injection: While a control group (Control; n=5 was injected with Freund's adjuvant solution in aquadest, the treatment groups were either firstly injected with progesterone conjugated to Freund's Adjuvant (P--CFA, 150 p.l : 150 pl or progesterone conjugated to Freund's Adjuvant and bovine serum albumin (P-CFA-BSA; 135 p;l : 150 tt1 : 15 gl. Twice boostering injections were adminstered using incomplete Freund's Adjuvant on day 14 and 52 after first immunization. Weekly bleeding for serum collection were done from 1 week following first booster immunization to week 10, Using ELISA technique it was shown that the antibody titer to progesterone after first and second booster immunization in the P-CFA groug was higher than Control- and P-CFA-BSA groups. The antibody titer in the P-CFA-BSA remained low similar in the Control group: Key words: antibody; progesterone; rabbit

  11. Space shuttle booster multi-engine base flow analysis

    Science.gov (United States)

    Tang, H. H.; Gardiner, C. R.; Anderson, W. A.; Navickas, J.

    1972-01-01

    A comprehensive review of currently available techniques pertinent to several prominent aspects of the base thermal problem of the space shuttle booster is given along with a brief review of experimental results. A tractable engineering analysis, capable of predicting the power-on base pressure, base heating, and other base thermal environmental conditions, such as base gas temperature, is presented and used for an analysis of various space shuttle booster configurations. The analysis consists of a rational combination of theoretical treatments of the prominent flow interaction phenomena in the base region. These theories consider jet mixing, plume flow, axisymmetric flow effects, base injection, recirculating flow dynamics, and various modes of heat transfer. Such effects as initial boundary layer expansion at the nozzle lip, reattachment, recompression, choked vent flow, and nonisoenergetic mixing processes are included in the analysis. A unified method was developed and programmed to numerically obtain compatible solutions for the various flow field components in both flight and ground test conditions. Preliminary prediction for a 12-engine space shuttle booster base thermal environment was obtained for a typical trajectory history. Theoretical predictions were also obtained for some clustered-engine experimental conditions. Results indicate good agreement between the data and theoretical predicitons.

  12. LS1 Report: PS beams are back!

    CERN Multimedia

    Katarina Anthony & Anaïs Schaeffer

    2014-01-01

    For the first time in over 15 months, there are beams back in the PS. Making their first tour of the accelerator today, 20 June, their injection marks the end of weeks of cold checkouts and hardware commissioning in the PS.   The CERN Control Centre (CCC) is back in business: people gather to restart the LHC injectors, today the PS. Since hardware commissioning was wrapped up on 23 May, the Operations Group (BE-OP) has been conducting cold checkouts on the PS. This involves switching on all of the machine's systems, verifying that they respond to commands by OP and ensuring they are calibrated to beam timings. "These verifications were done, in part, during the hardware commissioning dry runs," says Rende Steerenberg, PS section leader. "But the cold checkouts are on a much larger scale, as we act as if there is beam in the whole machine. We placed a full load on the controls system, cooling, networks, etc. in order to setup the accelerator in the most realis...

  13. Injection error monitor for KEK 12 GeV PS

    International Nuclear Information System (INIS)

    Shirakata, Masashi; Sato, Hikaru; Toyama, Takeshi; Marutsuka, Katsumi.

    1994-01-01

    The injection error monitor is now developing for an easy tuning of the main ring beam injection at the KEK 12 GeV proton synchrotron. The beam trajectory on the horizontal phase space plane is obtained by a test bench system. The injection error monitor proved to be available for the beam injection tuning. (author)

  14. Meningococcal serogroup C immunogenicity, antibody persistence and memory B-cells induced by the monovalent meningococcal serogroup C versus quadrivalent meningococcal serogroup ACWY conjugate booster vaccine: A randomized controlled trial.

    Science.gov (United States)

    van Ravenhorst, Mariëtte B; van der Klis, Fiona R M; van Rooijen, Debbie M; Knol, Mirjam J; Stoof, Susanne P; Sanders, Elisabeth A M; Berbers, Guy A M

    2017-08-24

    Adolescents are considered the key transmitters of meningococci in the population. Meningococcal serogroup C (MenC) antibody levels wane rapidly after MenC conjugate vaccination in young children, leaving adolescents with low antibody levels. In this study, we compared MenC immune responses after booster vaccination in adolescence with either tetanus toxoid conjugated MenC (MenC-TT) or MenACWY (MenACWY-TT) vaccine, and aimed to establish an optimal age for this booster. Healthy 10-, 12-, and 15-year-olds, who received a single dose of MenC-TT vaccine in early childhood, were randomized to receive MenC-TT or MenACWY-TT vaccine. MenC serum bactericidal antibody (rSBA) titers, MenC polysaccharide (PS) specific IgG, IgG1 and IgG2 and MenC-specific IgG and IgA memory B-cells were determined before, one month and one year after the booster. Non-inferiority was tested by comparing geometric mean titers (GMTs) between vaccinees at one year. Of 501 participants, 464 (92.6%) were included in the 'according to protocol' cohort analysis. At one month, all participants developed high MenC rSBA titers (>24,000 in all groups) and MenC-PS-specific IgG levels. Non-inferiority was not demonstrated one year after the booster with higher MenC GMTs after the monovalent vaccine, but 462/464 (99.6%) participants maintained protective MenC rSBA titers. IgG levels mainly consisted of IgG1, but similar levels of increase were observed for IgG1 and IgG2. Both vaccines induced a clear increase in the number of circulating MenC-PS specific IgG and IgA memory B-cells. Between one month and one year, the highest antibody decay rate was observed in the 10-year-olds. Both MenC-TT and MenACWY-TT vaccines induced robust protective MenC immune responses after the booster vaccination, although non-inferiority could not be demonstrated for the MenACWY-TT vaccine after one year. Our results underline the importance of optimal timing of a meningococcal booster vaccination to protect against MenC disease

  15. Differential induction and spread of tau pathology in young PS19 tau transgenic mice following intracerebral injections of pathological tau from Alzheimer’s disease or corticobasal degeneration brains

    Science.gov (United States)

    Boluda, Susana; Iba, Michiyo; Zhang, Bin; Raible, Kevin M.; Lee, Virginia M-Y.; Trojanowski, John Q.

    2015-01-01

    Filamentous tau pathologies are hallmark lesions of several neurodegenerative tauopathies including Alzheimer’s disease (AD) and corticobasal degeneration (CBD) which show cell type-specific and topographically distinct tau inclusions. Growing evidence supports templated transmission of tauopathies through functionally interconnected neuroanatomical pathways suggesting that different self-propagating strains of pathological tau could account for the diverse manifestations of neurodegenerative tauopathies. Here, we describe the rapid and distinct cell type-specific spread of pathological tau following intracerebral injections of CBD or AD brain extracts enriched in pathological tau (designated CBD-Tau and AD-Tau, respectively) in young human mutant P301S tau transgenic (Tg) mice (line PS19) ~6–9 months before they show onset of mutant tau transgene-induced tau pathology. At 1 month post-injection of CBD-Tau, tau inclusions developed predominantly in oligodendrocytes of the fimbria and white matter near the injection sites with infrequent intraneuronal tau aggregates. In contrast, injections of AD-Tau in young PS19 mice induced tau pathology predominantly in neuronal perikarya with little or no oligodendrocyte involvement 1 month post-injection. With longer post-injection survival intervals of up to 6 months, CBD-Tau- and AD-Tau-induced tau pathology spread to different brain regions distant from the injection sites while maintaining the cell type-specific pattern noted above. Finally, CA3 neuron loss was detected 3 months post-injection of AD-Tau but not CBD-Tau. Thus, AD-Tau and CBD-Tau represent specific pathological tau strains that spread differentially and may underlie distinct clinical and pathological features of these two tauopathies. Hence, these strains could become targets to develop disease-modifying therapies for CBD and AD. PMID:25534024

  16. Formation of a single-bunch beam in the booster synchrotron at SPring-8

    CERN Document Server

    Suzuki, H; Ego, H; Hara, M; Hosoda, N; Kawashima, Y; Ohashi, Y; Ohshima, T; Tani, N; Yabashi, M; Yonehara, H

    2000-01-01

    In order to fill a radio frequency (rf) bucket with an electron beam in the storage ring at SPring-8, an rf knockout system was installed in the booster synchrotron. With this system, the energy of the electron beam injected from the linac was increased from 1 to 8 GeV. The time width of multi-bunch beams from the linac operated at 2856 MHz rf can be selected as 1 or 40 ns. The beam injected from the linac is distributed in rf buckets of the booster synchrotron operated at 508.58 MHz rf. To fill a single rf bucket with a beam, the rf knockout system is operated at a minimum beam energy of 1 GeV. By using the rf knockout system, the electron beam is effectively kept in a single rf bucket. Then the beam is injected into a targeted rf bucket in the storage ring with a precise timing system. The beam intensity of satellite rf buckets in the storage ring was measured with a photon counting method and determined to be 10 sup - sup 6 less than that of the main rf bucket. In this paper, we describe the rf knockout sy...

  17. RF Scenarios for Pb54+ Ions in the PS2

    CERN Document Server

    Benedikt, M; Hancock, S; CERN. Geneva. AB Department

    2008-01-01

    This note analyses some of the rf scenarios that are presently being considered for lead ions in the PS2. An earlier note principally concerning protons [1] highlighted the problem of the large revolution frequency swing of ions in the PS2 and the issue of bunching factor with direct injection from the LEIR machine. We present solutions based on additional rf systems in LEIR and consider the 40 MHz principal rf system proposed for the PS2 in the earlier work to have switchable tuning ranges to cover the large frequency swing required.

  18. Operational behaviour of CO{sub 2} booster systems; Betriebsverhalten von CO{sub 2}-Booster-Systemen

    Energy Technology Data Exchange (ETDEWEB)

    Javerschek, Oliver; Hieble, Tobias [BITZER Kuehlmaschinenbau GmbH, Sindelfingen (Germany)

    2011-07-01

    The operating characteristics of booster systems and the resulting operating conditions of CO{sub 2} booster systems in supermarket refrigeration are explained and discussed. Criteria and challenges of different operating and load conditions are gone into. Simulated and measured operating states of a small-scale booster system are compared and evaluated. [German] In der vorliegenden Veroeffentlichung werden unterschiedliche Betriebsverhalten und die daraus resultierenden Betriebsbedingungen von CO{sub 2}-Booster-Systemen in der Supermarktkaelte erlaeutert und diskutiert. Dabei werden wesentliche Kriterien und Herausforderungen bei den unterschiedlichen Betriebs- und Lastbedingungen besprochen. Ausserdem werden simulierte und gemessene Betriebszustaende einer kleinen Booster-Kaelteanlage vergleichend betrachtet und bewertet.

  19. Construction and early commissioning results of the AGS Booster

    International Nuclear Information System (INIS)

    Weng, W.T.; Ahrens, L.; Damm, R.; McNerney, A.J.

    1991-01-01

    The AGS Booster synchrotron has been designed to accelerate protons from 200 MeV to 1.5 GeV and heavy ions from several MeV per nucleon to several hundred MeV per nucleon for all the nuclei up to gold. The design requirements and measurements results of major accelerator components and systems are presented. The early commissioning results of the injection is also presented. 12 refs., 9 figs., 2 tabs

  20. A Project Of The 2.5 Gev Booster-synchrotron In Binp

    CERN Document Server

    Barbashin, V M; Kremyanskaya, E V; Kvardakov, V A; Levichev, E B; Mishnev, S I; Skrinsky, A N; Smaluk, V V

    2004-01-01

    A project of the 2.5 GeV booster synchrotron to provide effective injection of electron and positron beams into VEPP-2000 and VEPP-4M storage rings, and for future facilities, is developing in BINP. The beams are injected to synchrotron at 510 MeV energy from a damping ring, which is the part of the new injection facility [1]. Small transverse size of the beam extracted from the damping ring allows us to design the synchrotron with rather small acceptance. Therefore, the aperture can be reduced essentially, which also decreases dimensions of the magnets and their power-consuming. In this report, the synchrotron parameters are presented, the basic systems are briefly described.

  1. Proceedings of the workshop on deuteron beam acceleration in the KEK 12 GeV PS

    International Nuclear Information System (INIS)

    Mori, Yoshiharu

    1991-12-01

    The acceleration of atomic nucleus beam with the 12 GeV proton synchrotron in National Laboratory for High Energy Physics (KEK-PS) has been demanded by the experimenters of nuclear physics, and there was the move to concretely realize it at the beginning of 1980, but actually it was not materialized up to now due to various circumstances. The reason that makes the acceleration even in light nuclear beam like deuterons difficult is various, but one is that the acceleration method considered so far particularly in a booster main ring is very complicated. Recently as one of the various proposals made from the viewpoint of the future utilization of the KEK-PS, that of using nuclear beam and the experiment with the PS-collider have been discussed, and the method of accelerating nuclear beam in the PS was reexamined. As the result, together with the technical progress such as ring RF and linear accelerator augmentation, the method with high realization possibility became to be proposed. This proceedings is the report of the first workshop on deutron acceleration held on February 20, 1991, to prepare for the experiment using deuteron beam. (K.I.)

  2. Electron cooling system in the booster synchrotron of the HIAF project

    Energy Technology Data Exchange (ETDEWEB)

    Mao, L.J., E-mail: maolijun@impcas.ac.cn [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Yang, J.C.; Xia, J.W.; Yang, X.D.; Yuan, Y.J.; Li, J.; Ma, X.M.; Yan, T.L.; Yin, D.Y.; Chai, W.P.; Sheng, L.N. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Shen, G.D.; Zhao, H.; Tang, M.T. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Graduate University of Chinese Academy of Sciences, Beijing 100049 (China)

    2015-06-21

    The High Intensity heavy ion Accelerator Facility (HIAF) is a new accelerator complex under design at the Institute of Modern Physics (IMP). The facility is aiming at the production of high intensity heavy ion beams for a wide range of experiments in high energy density physics, nuclear physics, atomic physics and other applications. It consists of a superconducting electron-cyclotron-resonance ion source and an intense proton ion source, a linear accelerator, a 34 Tm booster synchrotron ring, a 43 Tm multifunction compression synchrotron ring, a 13 Tm high precision spectrometer ring and several experimental terminals. A magnetized electron cooling device is supposed to be used in the booster ring for decreasing the transverse emittance of injected beams. The conceptual design and main parameters of this cooler are presented in this paper.

  3. Tomography at Injection in the PSB

    CERN Document Server

    Hancock, Steven

    2016-01-01

    The PSB was conceived as an intensity booster for fixed-target physics. Consequently, no attempt was ever made to synchronize the turns injected into each ring with the rf in that ring because as many as a dozen such turns were expected to be superposed longitudinally [1]. When only a small, non-integer number of turns is injected, this asynchronism results in a particle distribution whose initial phase fluctuates wildly from shot to shot with respect to the rf bucket into which it is subsequently captured. This has long been suspected to be an ingredient in the intensity non-reproducibility observed for low-intensity beams, such as pilot beams for the LHC [2]. An MD cycle has been built to pursue this suspicion (in one ring, at least) by introducing, in a fully ppm fashion, distributor timings that are first resynchronized to the rf train of Ring3 and that then count 40 MHz clock ticks to reduce any jitter to just 25 ns (cf., the bucket duration at Booster injection is 1.67 μs). Leaving aside the origin...

  4. Around the laboratories: Dubna: Physics results and progress on bubble chamber techniques; Stanford (SLAC): Operation of a very rapid cycling bubble chamber; Daresbury: Photographs of visitors to the Laboratory; Argonne: Charge exchange injection tests into the ZGS in preparation for a proposed Booster

    CERN Multimedia

    1969-01-01

    Around the laboratories: Dubna: Physics results and progress on bubble chamber techniques; Stanford (SLAC): Operation of a very rapid cycling bubble chamber; Daresbury: Photographs of visitors to the Laboratory; Argonne: Charge exchange injection tests into the ZGS in preparation for a proposed Booster

  5. Progress on the Design of a Perpendicularly Biased 2nd Harmonic Cavity for the Fermilab Booster

    Energy Technology Data Exchange (ETDEWEB)

    Madrak, R. L. [Fermilab; Dey, J. E. [Fermilab; Duel, K. L. [Fermilab; Kuharik, J. C. [Fermilab; Pellico, W. A. [Fermilab; Reid, J. S. [Fermilab; Romanov, G. [Fermilab; Slabough, M. [Fermilab; Sun, D. [Fermilab; Tan, C. Y. [Fermilab; Terechkine, I. [Fermilab

    2016-10-01

    perpendicularly biased 2nd harmonic cavity is being designed and built for the Fermilab Booster. Its purpose is to flatten the bucket at injection and thus change the longitudinal beam distribution to decrease space charge effects. It can also help at extraction. The cavity frequency range is 76 – 106 MHz. The power amplifier will be built using the Y567B tetrode, which is also used for the fundamental mode cavities in the Fermilab Booster. We discuss recent progress on the cavity, the biasing solenoid design and plans for testing the tuner's garnet material

  6. Pressure-Equalizing Cradle for Booster Rocket Mounting

    Science.gov (United States)

    Rutan, Elbert L. (Inventor)

    2015-01-01

    A launch system and method improve the launch efficiency of a booster rocket and payload. A launch aircraft atop which the booster rocket is mounted in a cradle, is flown or towed to an elevation at which the booster rocket is released. The cradle provides for reduced structural requirements for the booster rocket by including a compressible layer, that may be provided by a plurality of gas or liquid-filled flexible chambers. The compressible layer contacts the booster rocket along most of the length of the booster rocket to distribute applied pressure, nearly eliminating bending loads. Distributing the pressure eliminates point loading conditions and bending moments that would otherwise be generated in the booster rocket structure during carrying. The chambers may be balloons distributed in rows and columns within the cradle or cylindrical chambers extending along a length of the cradle. The cradle may include a manifold communicating gas between chambers.

  7. Experimental study of 『PERSICAE SEMEN』 on the blood injected by Endotoxin in rats

    Directory of Open Access Journals (Sweden)

    Chang-Keun

    2005-06-01

    Full Text Available This study was performed to investigate the effects of 「Persicae Semen」(PS on the blood injected by Endotoxin in rats. The blood was induced by Endotoxin injection into the caudal vein of rats and PS group taken a measurement of RBC, Hb, Hct, Platelet, WBC, ESR, CRP. The results were obtained as follows: 1. RBC, Hb, Hct, Platelet, WBC were increased with statistical significance at PS group as compared with those of the control group. 2. ESR, CRP were decreased with statistical significance at PS group as compared with those of the control group. It is concluded that PS group has significant effects on the blood injected by Endotoxin in rats. Therefore, PS group seems to be applicable to the diseases related to Endotoxin in clinics.

  8. On the crystallization behavior of syndiotactic-b-atactic polystyrene stereodiblock copolymers, atactic/syndiotactic polystyrene blends, and aPS/sPS blends modified with sPS-b-aPS

    Energy Technology Data Exchange (ETDEWEB)

    Annunziata, Liana, E-mail: liana.annunziatta@univ-rennes1.fr [Organométalliques et Catalyse, UMR 6226 Sciences Chimiques CNRS, Université de Rennes 1, Campus de Beaulieu, F-35042 Rennes Cedex (France); Monasse, Bernard, E-mail: bernard.monasse@mines-paristech.fr [Mines-ParisTech, CEMEF, Centre de Mise en Forme des Matériaux, UMR CNRS 7635, Sophia Antipolis (France); Rizzo, Paola; Guerra, Gaetano [Dipartimento di Chimica e Biologia, Università degli studi di Salerno, Via Ponte don Melillo, I-84084 Fisciano, SA (Italy); Duc, Michel [Total Petrochemicals Research Feluy, Zone Industrielle Feluy C, B-7181 Seneffe (Belgium); Carpentier, Jean-François, E-mail: jean-francois.carpentier@univ-rennes1.fr [Organométalliques et Catalyse, UMR 6226 Sciences Chimiques CNRS, Université de Rennes 1, Campus de Beaulieu, F-35042 Rennes Cedex (France)

    2013-09-16

    Crystallization and morphological features of syndiotactic-b-atactic polystyrene stereodiblock copolymers (sPS-b-aPS), atactic/syndiotactic polystyrene blends (aPS/sPS), and aPS/sPS blends modified with sPS-b-aPS, with different compositions in aPS and sPS, have been investigated using differential scanning calorimetry (DSC), polarized light optical microscopy (POM) and wide angle X-ray diffraction (WAXRD) techniques. For comparative purposes, the properties of parent pristine sPS samples were also studied. WAXRD analyses revealed for all the samples, independently from their composition (aPS/sPS ratio) and structure (blends, block copolymers, blends modified with block copolymers), the same polymorphic β form of sPS. The molecular weight of aPS and sPS showed opposite effects on the crystallization of 50:50 aPS/sPS blends: the lower the molecular weight of aPS, the slower the crystallization while the lower the molecular weight of sPS, the faster the crystallization. DSC studies performed under both isothermal and non-isothermal conditions, independently confirmed by POM studies, led to a clear trend for the crystallization rate at a given sPS/aPS ratio (ca. 50:50 and 20:80): sPS homopolymers > sPS-b-aPS block copolymers ∼sPS/aPS blends modified with sPS-b-aPS copolymers > sPS/aPS blends. Interestingly, sPS-b-aPS block copolymers not only crystallized faster than blends, but also affected positively the crystallization behavior of blends. At 50:50 sPS/aPS ratio, blends (Blend-2), block copolymers (Cop-1) and blends modified with block copolymers (Blend-2-mod) crystallized via spherulitic crystalline growth controlled by an interfacial process. In all cases, an instantaneous nucleation was observed. The density of nuclei in block copolymers (160,000−190,000 nuclei mm{sup −3}) was always higher than that in blends and modified blends (30,000−60,000 nuclei mm{sup −3}), even for quite different sPS/aPS ratio. At 20:80 sPS/aPS ratio, the block copolymers

  9. AGS booster prototype magnets

    International Nuclear Information System (INIS)

    Danby, G.; Jackson, J.; Lee, Y.Y.; Phillips, R.; Brodowski, J.; Jablonski, E.; Keohane, G.; McDowell, B.; Rodger, E.

    1987-01-01

    Prototype magnets have been designed and constructed for two half cells of the AGS Booster. The lattice requires 2.4m long dipoles, each curved by 10 0 . The multi-use Booster injector requires several very different standard magnet cycles, capable of instantaneous interchange using computer control from dc up to 10 Hz

  10. Booster extraction, booster-to-storage ring transport and storage ring injection for the ALS

    International Nuclear Information System (INIS)

    Zisman, M.S.

    1988-03-01

    A status report on the design of the ALS injection system is presented. The various modifications that have occurred since the time of the ALS Conceptual Design Report in July, 1986 are described, along with the reasons for the changes. 1 ref., 12 figs

  11. AGS Booster prototype magnets

    Energy Technology Data Exchange (ETDEWEB)

    Danby, G.; Jackson, J.; Lee, Y.Y.; Phillips, R.; Brodowski, J.; Jablonski, E.; Keohane, G.; McDowell, B.; Rodger, E.

    1987-03-19

    Prototype magnets have been designed and constructed for two half cells of the AGS Booster. The lattice requires 2.4m long dipoles, each curved by 10/sup 0/. The multi-use Booster injector requires several very different standard magnet cycles, capable of instantaneous interchange using computer control from dc up to 10 Hz.

  12. Immunity booster

    International Nuclear Information System (INIS)

    Stefanescu, Ioan; Titescu, Gheorghe; Tamaian, Radu; Haulica, Ion; Bild, Walther

    2002-01-01

    The immunity booster is, according to its patent description, microbiologically pure water with an D/(D+H) isotopic concentration of 100 ppm, with physical-chemical characteristics similar to those of distilled water. It is obtained by sterilization of a mixture of deuterium depleted water, with a 25 ppm isotopic concentration, with distilled water in a volume ratio of 4:6. Unlike natural immunity boosters (bacterial agents as Bacillus Chalmette-Guerin, Corynebacterium parvum; lipopolysaccharides; human immunoglobulin) or synthetical products (levamysol; isoprinosyne with immunostimulating action), which cause hypersensitivity and shocks, thrill, fever, sickness and the immunity complex disease, the water of 100 ppm D/(D + H) isotopic concentration is a toxicity free product. The testing for immune reaction of the immunity booster led to the following results: - an increase of cell action capacity in the first immunity shielding stage (macrophages), as evidenced by stimulation of a number of essential characterizing parameters, as well as of the phagocytosis capacity, bactericide capacity, and opsonic capacity of serum; - an increase of the number of leucocyte particularly of the granulocyte in peripheral blood, produced especially when medullar toxic agents like caryolysine are used; - it hinders the effect of lowering the number of erythrocytes in peripheral blood produced by experimentally induced chronic inflammation; - an increase of nonspecific immunity defence capacity against specific bacterial aggression of both Gram-positive bacteria (Streptococcus pneumoniae 558 ) and of the Gram-negative ones (Klebsiella pneumoniae 507 ); - an increase of immunity - stimulating activity (proinflamatory), like that of levamisole as evidenced by the test of stimulation of experimentally induced inflammation by means of carrageenan. The following advantages of the immunity booster are stressed: - it is toxicity free and side effect free; - can be orally administrated as

  13. Enhanced personal protection system for the PS

    CERN Multimedia

    Caroline Duc

    2013-01-01

    During the first long shutdown (LS1) a new safety system will be installed in the primary beam areas of the PS complex in order to bring the standard of personnel radiation protection at the PS into line with that of the LHC.   Pierre Ninin, deputy group leader of GS-ASE and responsible for the installation of the new PS complex safety system, in front of a new access control system. The LHC access control systems are state-of-the-art, whereas those of the injection chain accelerators were running the risk of becoming obsolete. For the past two years a project to upgrade the access and safety systems of the first links in the LHC accelerator chain has been underway to bring them into compliance with nuclear safety standards. These systems provide the personnel with automatic protection by limiting access to hazardous areas and by ensuring that nobody is present in the areas when the accelerator is in operation. By the end of 2013, the project teams will ha...

  14. 47 CFR 74.733 - UHF translator signal boosters.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false UHF translator signal boosters. 74.733 Section... Translator, and TV Booster Stations § 74.733 UHF translator signal boosters. (a) The licensee of a UHF television broadcast translator station may be authorized to operate one or more signal boosters for the...

  15. The Effects of Space-Charge on the Dynamics of the Ion Booster in the Jefferson Lab EIC (JLEIC)

    Energy Technology Data Exchange (ETDEWEB)

    Bogacz, Alex [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Nissen, Edward [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2017-05-01

    Optimization of the booster synchrotron design to operate in the extreme space-charge dominated regime is proposed. This study is motivated by the ultra-high luminosity promised by the JLEIC accelerator complex, which poses several beam dynamics and lattice design challenges for its individual components. We examine the effects of space charge on the dynamics of the booster synchrotron for the proposed JLEIC electron ion collider. This booster will inject and accumulate protons and heavy ions at an energy of 280 MeV and then engage in a process of acceleration and electron cooling to bring it to its extraction energy of 8 GeV. This would then be sent into the ion collider ring part of JLEIC. In order to examine the effects of space charge on the dynamics of this process we use the software SYNERGIA.

  16. Theoretical considerations regarding the existence of PsO and PsS+

    International Nuclear Information System (INIS)

    Farazdel, A.; Cade, P.E.

    1977-01-01

    It has been proposed from experimental studies and in analogy with hydrogen compounds that PsO may be an entity of some importance, or an intermediate, in the reaction of positronium, Ps, with aqueous oxyacid species such as H 2 PO 4 - , HSO 4 - , ClO 4 - , and NO 3 - . This communication explores the stability of PsO and PsS, or [O - :e + ] and [S - :e + ], respectively, relative to dissociation into Ps and O( 3 P) or S( 3 P) on the basis of restricted Hartree-Fock calculations for the PsO and PsS systems and certain correlation correction arguments. A reasonable lower estimate of the dissociation energy to Y+Ps of >-0.47 eV for PsO and >0.70 eV for PsS is obtained. It is suggested that a modest correlation correction to the positron affinity (PA) of O - would very probably lead to a bound state system for PsO. (Auth.)

  17. Magnetic field errors tolerances of Nuclotron booster

    Science.gov (United States)

    Butenko, Andrey; Kazinova, Olha; Kostromin, Sergey; Mikhaylov, Vladimir; Tuzikov, Alexey; Khodzhibagiyan, Hamlet

    2018-04-01

    Generation of magnetic field in units of booster synchrotron for the NICA project is one of the most important conditions for getting the required parameters and qualitative accelerator operation. Research of linear and nonlinear dynamics of ion beam 197Au31+ in the booster have carried out with MADX program. Analytical estimation of magnetic field errors tolerance and numerical computation of dynamic aperture of booster DFO-magnetic lattice are presented. Closed orbit distortion with random errors of magnetic fields and errors in layout of booster units was evaluated.

  18. Immunogenesity of spesific protein molecular weight 16 KDa (PS16 leaf of siam citrus infected by citrus vein phloem degeneration (CVPD disease

    Directory of Open Access Journals (Sweden)

    Made Sritamin

    2012-02-01

    Full Text Available Citrus Vein Phloem degeneration (CVPD is an important citrus disese, which damaged citrus plantation and causing decrease of citrus production. In Indonesia, the CVPD disease caused by Liberobacter asiaticum bactery and the disease spread out by vectir insect Diaphorina citri and using infected bud in wood grafting. In infected citrus plant, two specific protein molecules with molecular weigt 16 kDa and 66 kDa are found. These protein molecules are not found in healthy citrus plant. The immunogenicity of PS16 accumulated on leaf of citrus plant infected by CVPD is known yet. The research material were leaves of citrus plant infected CVPD, leaves of healthy citrus plant and reagent used these research are for isolation of the total protein leaf of citrus plant, SDS-PAGE electroforesis, electroelution of PS16, ELISA Methods, Dot-Blot Method, anti-PS16 as aprimery antibody and secondary antibody is anti-Rabbit IgG Conjugated AP. The result of the research showed that of PS16 accumulated on leaf of citrus plant infected CVPD has immunogenic character. It is indicated by increase of the titer anti-PS16 after first immunization ang 2nd booster by indirect ELISA method and can be used to induce antibody (anti-PS16 and so showed that positive reaction between PS16 with anti-PS16. It is indicated by purples dark blue on cellulose membrane by Dot Blot method.

  19. Reducing the beam current in Linac4 in pulse to pulse mode.

    CERN Document Server

    Lallement, JB; CERN. Geneva. BE Department

    2009-01-01

    In order to deliver different beam intensities to users, we studied the possibility of varying the Linac4 beam current at PS Booster injection in pulse to pulse mode. This report gives the possible configurations of Linac4 Low and Medium Energy Beam Transport lines (LEBT and MEBT) that lead to a consistent current reduction.

  20. Injection and extraction for cyclotrons

    International Nuclear Information System (INIS)

    Heikkinen, P.

    1994-01-01

    External ion sources for cyclotrons are needed for polarised and heavy ions. This calls for injection systems, either radial or axial. Radial injection is also needed when a cyclotron works as a booster after another cyclotron or a linear accelerator (usually tandem). Requirements for injection differ from separated sector cyclotrons where there is plenty of room to house inflectors and/or strippers, to superconducting cyclotrons where the space is limited by a small magnet gap, and high magnetic field puts other limitations to the inflectors. Several extraction schemes are used in cyclotrons. Stripping injection is used for H - and also for heavy ions where the q/m ratio is usually doubled. For other cases, electric and magnetic deflection has to be used. To increase the turn separation before the first deflector, both resonant and non-resonant schemes are used. In this lecture, external injection systems are surveyed and some rules to thumb for injection parameters are given. Extraction schemes are also reviewed. (orig.)

  1. Effect of reduced dose schedules and intramuscular injection of anthrax vaccine adsorbed on immunological response and safety profile: a randomized trial.

    Science.gov (United States)

    Wright, Jennifer G; Plikaytis, Brian D; Rose, Charles E; Parker, Scott D; Babcock, Janiine; Keitel, Wendy; El Sahly, Hana; Poland, Gregory A; Jacobson, Robert M; Keyserling, Harry L; Semenova, Vera A; Li, Han; Schiffer, Jarad; Dababneh, Hanan; Martin, Sandra K; Martin, Stacey W; Marano, Nina; Messonnier, Nancy E; Quinn, Conrad P

    2014-02-12

    We evaluated an alternative administration route, reduced schedule priming series, and increased intervals between booster doses for anthrax vaccine adsorbed (AVA). AVA's originally licensed schedule was 6 subcutaneous (SQ) priming injections administered at months (m) 0, 0.5, 1, 6, 12 and 18 with annual boosters; a simpler schedule is desired. Through a multicenter randomized, double blind, non-inferiority Phase IV human clinical trial, the originally licensed schedule was compared to four alternative and two placebo schedules. 8-SQ group participants received 6 SQ injections with m30 and m42 "annual" boosters; participants in the 8-IM group received intramuscular (IM) injections according to the same schedule. Reduced schedule groups (7-IM, 5-IM, 4-IM) received IM injections at m0, m1, m6; at least one of the m0.5, m12, m18, m30 vaccine doses were replaced with saline. All reduced schedule groups received a m42 booster. Post-injection blood draws were taken two to four weeks following injection. Non-inferiority of the alternative schedules was compared to the 8-SQ group at m2, m7, and m43. Reactogenicity outcomes were proportions of injection site and systemic adverse events (AEs). The 8-IM group's m2 response was non-inferior to the 8-SQ group for the three primary endpoints of anti-protective antigen IgG geometric mean concentration (GMC), geometric mean titer, and proportion of responders with a 4-fold rise in titer. At m7 anti-PA IgG GMCs for the three reduced dosage groups were non-inferior to the 8-SQ group GMCs. At m43, 8-IM, 5-IM, and 4-IM group GMCs were superior to the 8-SQ group. Solicited injection site AEs occurred at lower proportions in the IM group compared to SQ. Route of administration did not influence the occurrence of systemic AEs. A 3 dose IM priming schedule with doses administered at m0, m1, and m6 elicited long term immunological responses and robust immunological memory that was efficiently stimulated by a single booster vaccination at

  2. 80 kV electrostatic wire septum for AmPS

    International Nuclear Information System (INIS)

    Linden, A. van der; Bijleveld, J.H.M.; Rookhuizen, H.B.; Bruinsma, P.J.T.; Heine, E.; Lassing, P.; Prins, E.

    1992-01-01

    The Amsterdam Pulse Stretcher (AmPS) ring aims at a 100% duty cycle operation by means of slow extraction of injected electron beam pulses of 2.1 μs. In the extraction process of the AmPS, the extracted beam is intercepted from the circulating beam by the 1 m long electrostatic wire septum. For a bending angle of 4.4 mrad the maximum anode voltage is 80 kV. Care has been given to the electric field distribution at the entrance and exit of the septum and to the insulators, required to support the anode. Prototype tests have been successful up to an anode voltage of 120 kV. (R.P.) 9 refs.; 5 figs

  3. Predictors of response to intra-articular steroid injection in psoriatic arthritis.

    Science.gov (United States)

    Eder, Lihi; Chandran, Vinod; Ueng, Joanna; Bhella, Sita; Lee, Ker-Ai; Rahman, Proton; Pope, Angela; Cook, Richard J; Gladman, Dafna D

    2010-07-01

    To assess the effectiveness of IA corticosteroid (IAS) injections in PsA and to determine the association between macrophage migration inhibition factor (MIF) gene polymorphism and response to IAS injections. A cohort analysis of PsA patients who were followed prospectively was performed. Clinical response was defined as no tenderness or effusion in the injected joint at 3 months. Relapse was defined as re-occurrence of joint pain or effusion. MIF 173C > G genotyping (rs755622) was performed. Two hundred and twenty patients with 245 IAS injections were included in the study. The probability of responding at 3 months was 41.6%. Within 12 months, 25.5% of the joints relapsed. Clinical factors that were associated with response included duration of psoriasis [Odds ratio (OR) 1.03] and the use of MTX or anti-TNF agents at the time of injection (OR 2.68). Factors that were associated with relapse included injection into large joints (OR 4.58) and elevated sedimentation rate (OR 15.0), whereas absence of clinical and/or radiographic damage (OR 0.23) and duration of PsA (OR 0.92) reduced risk of relapse. MIF polymorphism was not associated with clinical response, but was associated with relapse (OR 3.2). On multivariate analysis including clinical covariates, the association between MIF polymorphism and relapse was lost. IAS injections are effective in PsA. MIF gene polymorphism is associated with relapse. However, this effect is explained by clinical variables that reflect disease activity, suggesting that MIF gene polymorphism influences inflammatory activity.

  4. Fox-7 for Insensitive Boosters

    Science.gov (United States)

    2010-08-01

    cavitation , and therefore nucleation, to occur at each frequency. As well as producing ultrasound at different frequencies, the method of delivery of...processing techniques using ultrasound , designed to optimise FOX-7 crystal size and morphology to improve booster formulations, and results from these...7 booster formulations. Also included are particle processing techniques using ultrasound , designed to optimise FOX-7 crystal size and morphology

  5. Measurement of transverse emittance in the Fermilab booster

    Energy Technology Data Exchange (ETDEWEB)

    Graves, William Sproull [Wisconsin U., Madison

    1994-01-01

    A new beam profile monitor has been built and installed in the Fermilab Booster synchrotron. It nondestructively measures the beam's vertical density distribution on a fast turn-by-turn basis. This enables one to measure the beam's transverse emittance and to observe emittance growth as it occurs. For high intensities (>2 times 10^{12 } protons), the normalized 95% emittance was observed to grow from 6pi mm-mrad at injection to 16pi mm-mrad at extraction. The initial (<5 msec) emittance growth and beam losses are shown to be caused by the space charge tune shift onto integer and 1/2 integer resonance lines. The growth near injection accounts for approximately 40% of the observed emittance increase throughout the acceleration cycle. The remaining 60% is due to two factors: slow linear growth due to betatron-motion driven by noise in the rf system; and faster growth after the transition energy that is caused by coupling of the longitudinal beam motion into the transverse planes.

  6. RF cogging in the FNAL Booster Accelerator

    International Nuclear Information System (INIS)

    William A. Pellico and Robert C. Webber

    2000-01-01

    The Fermilab Booster operates at a Radio Frequency (RF) harmonic number of 84 with beam in all buckets. One or two bunches of beam are systematically lost in the 8 GeV extraction process as beam is swept across a magnetic septum during the extraction kicker rise time. The prompt radiation and component activation resulting from this localized high energy beam loss become serious concerns as Booster beam throughput must be increased more than tenfold to meet the requirements of RUN II, NUMI, and MiniBooNE experiments. Synchronizing a gap in the beam to the firing of the extraction kickers, a relatively easy and standard practice in many machines, can eliminate the problem. This seemingly simple operation is greatly complicated in the Booster by the need to synchronize extraction to beam already circulating in the Main Injector. Coupled with the inflexibility of the Booster resonant magnetic cycle, cycle to cycle variations, and constraints inherent in the accelerator physics, that requirement forces active control of the gap's azimuthal position throughout the acceleration process as the revolution frequency sweeps rapidly. Until recently, the complexities of actually implementing and demonstrating this process in the Booster had not been worked out. This paper describes a successful demonstration of gap cogging in the Booster

  7. The safety and reactogenicity of a reduced-antigen-content diphtheria-tetanus-acellular pertussis (dTpa) booster vaccine in healthy Vietnamese children.

    Science.gov (United States)

    Anh, Dang Duc; Jayadeva, Girish; Kuriyakose, Sherine; Han, Htay Htay

    2016-08-17

    Despite effective infant immunization against pertussis, the disease continues to circulate due to waning immunity. Booster vaccinations against pertussis beyond infancy are widely recommended. In Vietnam, however, no recommendations for pertussis boosters beyond the second year of life exist. This open-label, single-centre study was designed to assess the safety of a single booster dose of reduced-antigen-content-diphtheria-tetanus-acellular-pertussis vaccine (dTpa) in 300 healthy Vietnamese children (mean age 7.9years), who had completed primary vaccination against diphtheria, tetanus and pertussis. Solicited symptoms were recorded for 4days and unsolicited and serious adverse events (SAEs) for 31days post-vaccination. Pain and fatigue were the most common solicited local and general symptoms in 35.0% and 14.0% of children, respectively. Grade 3 swelling occurred in 3 children; no large injection site reactions or SAEs were reported. The dTpa booster vaccine was well tolerated and this study supports its administration in school age Vietnamese children. Copyright © 2016 GSK group of companies. Published by Elsevier Ltd.. All rights reserved.

  8. Beam transfer between the coupled cavity linac and the low energy booster synchrotron for the SSC [Superconducting Super Collider

    International Nuclear Information System (INIS)

    Bhandari, R.K.; Penner, S.

    1990-09-01

    Ion optical design of the transfer line, which will be used to inject H - beam at 600 MeV from the Coupled Cavity Linac (CCL) into the Low Energy Booster (LEB) synchrotron, is described. Space charge effects of up to 50 mA average beam current have been taken into account

  9. Summary of Booster Development and Qualification Report

    Energy Technology Data Exchange (ETDEWEB)

    Francois, Elizabeth G. [Los Alamos National Laboratory; Harry, Herbert H. [Los Alamos National Laboratory; Hartline, Ernest L. [Los Alamos National Laboratory; Hooks, Daniel E. [Los Alamos National Laboratory; Johnson, Carl E. [Los Alamos National Laboratory; Morris, John S. [Los Alamos National Laboratory; Novak, Alan M. [Los Alamos National Laboratory; Ramos, Kyle J. [Los Alamos National Laboratory; Sanders, Victor E. [Los Alamos National Laboratory; Scovel, Christina A. [Los Alamos National Laboratory; Lorenz, Thomas [LLNL; Wright, Mark [AWE; Botcher, Tod [PANTEX; Marx, Erin [NSWC-IHDIV; Gibson, Kevin [NSWC-IHDIV

    2012-06-21

    This report outlines booster development work done at Los Alamos National Laboratory from 2007 to present. The booster is a critical link in the initiation train of explosive assemblies, from complex devices like nuclear weapons to conventional munitions. The booster bridges the gap from a small, relatively sensitive detonator to an insensitive, but massive, main charge. The movement throughout the explosives development community is to use more and more insensitive explosive components. With that, more energy is needed out of the booster. It has to initiate reliably, promptly, powerfully and safely. This report is divided into four sections. The first provides a summary of a collaborative effort between LANL, LLNL, and AWE to identify candidate materials and uniformly develop a testing plan for new boosters. Important parameters and the tests required to measure them were defined. The nature of the collaboration and the specific goals of the participating partners has changed over time, but the booster development plan stands on its own merit as a complete description of the test protocol necessary to compare and qualify booster materials, and is discussed in its entirety in this report. The second section describes a project, which began in 2009 with the Department of Defense to develop replacement booster formulations for PBXN-7. Replacement of PBXN-7 was necessary because it contained Triaminotrinitrobenzene (TATB), which was becoming unavailable to the DoD and because it contained Cyclotrimethylenetrinitramine (RDX), which was sensitive and toxic. A LANL-developed explosive, Diaminoazoxyfurazan (DAAF), was an important candidate. This project required any replacement formulation be a drop-in replacement in existing munitions. This project was timely, in that it made use of the collaborative booster development project, and had the additional constraint of matching shock sensitivity. Additionally it needed to be a safety improvement, and a performance

  10. 30 CFR 57.8518 - Main and booster fans.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Main and booster fans. 57.8518 Section 57.8518... and Underground § 57.8518 Main and booster fans. (a) All mine main and booster fans installed and used...-cycle shutdowns or planned or scheduled fan maintenance or fan adjustments where air quality is...

  11. Improvement of seawater booster pump outlet check valve

    International Nuclear Information System (INIS)

    Li Xuning; Du Yansong; Huang Huimin

    2010-01-01

    Conventional island seawater booster pump set of QNPC 310 MWe unit are very important in the whole circulating cooling system, and the integrate function of seawater booster pump outlet check valve is the foundation of steady operation of the seawater booster pump set. The article mainly introduce that through the analyses to the reason to the problem that the seawater booster pump outlet check valve of QNPC 310 MWe unit appeared in past years by our team, and considering the influence of operation condition and circumstance, the team improve the seawater booster pump outlet check valve from swing check valve to shuttle check valve which operate more appropriately in the system. By the test of continuous practice, we make further modification to the inner structure of shuttle check valve contrapuntally, and therefore we solve the problem in seawater booster pump outlet check valve fundamentally which has troubled the security of system operation in past years, so we realize the aim of technical improvement and ensure that the system operate in safety and stability. (authors)

  12. Conceptual design report: superconducting booster

    International Nuclear Information System (INIS)

    1983-01-01

    The Superconducting Booster project includes the construction of a new high-voltage injector and buncher for the existing tandem, a magnetic transport system, an rf linac with superconducting resonators, and a rebuncher-debuncher. The booster will fit in existing space so that a new building is not required. The layout of the accelerator is given in Fig. I-1. The University of Washington is contributing approximately $1 M to this project

  13. Thermodynamic investigation of a booster-assisted ejector refrigeration system

    International Nuclear Information System (INIS)

    Zhao, Hongxia; Zhang, Ke; Wang, Lei; Han, Jitian

    2016-01-01

    Highlights: • COP based on thermal input increases with booster outlet pressure. • Both entrainment ratio and area ratio increase with booster outlet pressure. • COP based on work is larger than compressor-based refrigeration system. • An optimum booster outlet pressure obtains maximum COP based on work. • Exergy destruction occurs mainly in ejector, condenser, evaporator and generator. - Abstract: In order to improve performance of ejector refrigeration system, a booster is added before an ejector to enhance secondary flow pressure, which is called a booster assisted refrigeration system. Based on mass, momentum and energy conservation, a 1D model of ejector for optimal performance prediction was presented and validated with experimental data. A detailed study of working characteristics of the booster assisted ejector refrigeration system was carried out and compared against conventional ejector refrigeration system and compressor based refrigeration system, on the basis of first and second laws of thermodynamics. Effects of booster outlet pressure on COP_t_h based on thermal energy and COP_w based on work input, and also on entrainment ratio and area ratio of ejector were studied. The exergy destruction rates were also computed and analyzed for components of the booster-assisted ejector refrigeration system. Ways to reduce exergy destruction were discussed.

  14. Gas Test Loop Booster Fuel Hydraulic Testing

    International Nuclear Information System (INIS)

    Gas Test Loop Hydraulic Testing Staff

    2006-01-01

    The Gas Test Loop (GTL) project is for the design of an adaptation to the Advanced Test Reactor (ATR) to create a fast-flux test space where fuels and materials for advanced reactor concepts can undergo irradiation testing. Incident to that design, it was found necessary to make use of special booster fuel to enhance the neutron flux in the reactor lobe in which the Gas Test Loop will be installed. Because the booster fuel is of a different composition and configuration from standard ATR fuel, it is necessary to qualify the booster fuel for use in the ATR. Part of that qualification is the determination that required thermal hydraulic criteria will be met under routine operation and under selected accident scenarios. The Hydraulic Testing task in the GTL project facilitates that determination by measuring flow coefficients (pressure drops) over various regions of the booster fuel over a range of primary coolant flow rates. A high-fidelity model of the NW lobe of the ATR with associated flow baffle, in-pile-tube, and below-core flow channels was designed, constructed and located in the Idaho State University Thermal Fluids Laboratory. A circulation loop was designed and constructed by the university to provide reactor-relevant water flow rates to the test system. Models of the four booster fuel elements required for GTL operation were fabricated from aluminum (no uranium or means of heating) and placed in the flow channel. One of these was instrumented with Pitot tubes to measure flow velocities in the channels between the three booster fuel plates and between the innermost and outermost plates and the side walls of the flow annulus. Flow coefficients in the range of 4 to 6.5 were determined from the measurements made for the upper and middle parts of the booster fuel elements. The flow coefficient for the lower end of the booster fuel and the sub-core flow channel was lower at 2.3

  15. Gas Test Loop Booster Fuel Hydraulic Testing

    Energy Technology Data Exchange (ETDEWEB)

    Gas Test Loop Hydraulic Testing Staff

    2006-09-01

    The Gas Test Loop (GTL) project is for the design of an adaptation to the Advanced Test Reactor (ATR) to create a fast-flux test space where fuels and materials for advanced reactor concepts can undergo irradiation testing. Incident to that design, it was found necessary to make use of special booster fuel to enhance the neutron flux in the reactor lobe in which the Gas Test Loop will be installed. Because the booster fuel is of a different composition and configuration from standard ATR fuel, it is necessary to qualify the booster fuel for use in the ATR. Part of that qualification is the determination that required thermal hydraulic criteria will be met under routine operation and under selected accident scenarios. The Hydraulic Testing task in the GTL project facilitates that determination by measuring flow coefficients (pressure drops) over various regions of the booster fuel over a range of primary coolant flow rates. A high-fidelity model of the NW lobe of the ATR with associated flow baffle, in-pile-tube, and below-core flow channels was designed, constructed and located in the Idaho State University Thermal Fluids Laboratory. A circulation loop was designed and constructed by the university to provide reactor-relevant water flow rates to the test system. Models of the four booster fuel elements required for GTL operation were fabricated from aluminum (no uranium or means of heating) and placed in the flow channel. One of these was instrumented with Pitot tubes to measure flow velocities in the channels between the three booster fuel plates and between the innermost and outermost plates and the side walls of the flow annulus. Flow coefficients in the range of 4 to 6.5 were determined from the measurements made for the upper and middle parts of the booster fuel elements. The flow coefficient for the lower end of the booster fuel and the sub-core flow channel was lower at 2.3.

  16. Asymmetric PS-block-(PS-co-PB)-block-PS block copolymers: morphology formation and deformation behaviour

    International Nuclear Information System (INIS)

    Adhikari, Rameshwar; Huy, Trinh An; Buschnakowski, Matthias; Michler, Goerg H; Knoll, Konrad

    2004-01-01

    Morphology formation and deformation behaviour of asymmetric styrene/butadiene triblock copolymers (total polystyrene (PS) content ∼70%) consisting of PS outer blocks held apart by a styrene-co-butadiene random copolymer block (PS-co-PB) each were investigated. The techniques used were differential scanning calorimetry, transmission electron microscopy, uniaxial tensile testing and Fourier-transform infrared spectroscopy. A significant shift of the phase behaviour relative to that of a neat symmetric triblock copolymer was observed, which can be attributed to the asymmetric architecture and the presence of PS-co-PB as a soft block. The mechanical properties and the microdeformation phenomena were mainly controlled by the nature of their solid-state morphology. Independent of morphology type, the soft phase was found to deform to a significantly higher degree of orientation when compared with the hard phase

  17. Compatibility of booster seats and vehicles in the U.S. market.

    Science.gov (United States)

    Bing, Julie A; Agnew, Amanda M; Bolte, John H

    2018-05-19

    The objective of this study was to analyze booster and rear vehicle seat dimensions to identify the most frequent compatibility problems. Measurements were collected from 40 high-back and backless boosters and 95 left rear and center rear row seating positions in 50 modern vehicles. Dimensions were compared for 3,800 booster/vehicle seat combinations. For validation and estimation of tolerance and correction factors, 72 booster installations were physically completed and compared with measurement-based compatibility predictions. Dimensions were also compared to the International Organization for Standardization (ISO) volumetric envelopes of forward-facing child restraints and boosters. Seat belt buckles in outboard positions accommodated the width of boosters better than center positions (success rates of 85.4 and 34.7%, respectively). Adequate head restraint clearance occurred in 71.9 to 77.2% of combinations, depending on the booster's head support setting. Booster recline angles aligned properly with vehicle seat cushion angles in 71.5% of combinations. In cases of poor angle alignment, booster angles were more obtuse than the vehicle seat angles 97.7% of the time. Head restraint interference exacerbated angle alignment issues. Data indicate success rates above 90% for boosters being fully supported by the length of the seat cushion and for adequate height clearance with the vehicle roofline. Comparison to ISO envelopes indicates that most boosters on the U.S. market are taller and angled more obtusely than ISO target envelopes. This study quantifies some of the common interferences between boosters and vehicles that may complicate booster usage. Data are useful for design and to prioritize specific problem areas.

  18. Synthesis of NiPS3 and CoPS and its hydrogen storage capacity

    International Nuclear Information System (INIS)

    Ismail, N.; Madian, M.; El-Meligi, A.A.

    2014-01-01

    Highlights: • Preparation of NiPS 3 and CoPS using solid state reaction. • Characterization of compounds using XRD, TEM, SEM and IR. • Measuring the compounds thermal stability. • Estimation of the hydrogen storage capacity. -- Abstract: Prepared CoPS and NiPS 3 are studied as new materials for hydrogen energy storage. Single phase of CoPS and NiPS 3 were grown separately in evacuated silicatube via solid state reaction at 650 °C with controlled heating rate 1 °C/min. X-ray diffraction patterns confirm the formation of the desired compounds. Both CoPS and NiPS 3 exhibited high thermal stability up to 700 °C and 630 °C, respectively. The morphology of the prepared samples was investigated using scanning electron microscopy and folded sheets appeared in the transmission electron microscopy. The samples were exposed to 20 bar applied hydrogen pressure at 80 K. Both compounds appear to have feasible hydrogen storage capacity. CoPS was capable to adsorb 1.7 wt% while NiPS 3 storage capacity reached 1.2 wt%

  19. Alignment and Field Error Tolerance in Linac4

    CERN Document Server

    Bellodi, G; Garcia Tudela, M; Hein, L; Lallement, J B; Lanzone, S; Lombardi, A M; Posocco, P; Sargsyan, E

    2011-01-01

    LINAC4 [1] is a linear accelerator for negative Hydrogen ions (H−), which will replace the 50 MeV proton LINAC (LINAC2) as linear injector for the CERN accelerators. The higher output energy (160 MeV) together with charge-exchange injection will allow increasing beam intensity in the following machines. LINAC4 is about 80 m long, normal-conducting, and will be housed in a tunnel 12 m below ground on the CERN Meyrin site. The location has been chosen to allow using LINAC4 as the first stage of acceleration for a Multi-MegaWatt superconducting LINAC (SPL [2]). A 60 m long transfer line brings the beam towards the present LINAC2-to-PS Booster transfer line, which is joined at the position of BHZ20. The new transfer line consists of 17 new quadrupoles, an RF cavity and 4 bending magnets to adjust both the direction and the level for injection into the PS Booster. End-to-end beam dynamics simulations have been carried out in parallel with the codes PATH [3] and TRACEWIN[4]. Following the definition of the layout...

  20. Developing the World's Most Powerful Solid Booster

    Science.gov (United States)

    Priskos, Alex S.; Frame, Kyle L.

    2016-01-01

    NASA's Journey to Mars has begun. Indicative of that challenge, this will be a multi-decadal effort requiring the development of technology, operational capability, and experience. The first steps are underway with more than 15 years of continuous human operations aboard the International Space Station (ISS) and development of commercial cargo and crew transportation capabilities. NASA is making progress on the transportation required for deep space exploration - the Orion crew spacecraft and the Space Launch System (SLS) heavy-lift rocket that will launch Orion and large components such as in-space stages, habitat modules, landers, and other hardware necessary for deep-space operations. SLS is a key enabling capability and is designed to evolve with mission requirements. The initial configuration of SLS - Block 1 - will be capable of launching more than 70 metric tons (t) of payload into low Earth orbit, greater mass than any other launch vehicle in existence. By enhancing the propulsion elements and larger payload fairings, future SLS variants will launch 130 t into space, an unprecedented capability that simplifies hardware design and in-space operations, reduces travel times, and enhances two solid propellant five-segment boosters, both based on space shuttle technologies. This paper will focus on development of the booster, which will provide more than 75 percent of total vehicle thrust at liftoff. Each booster is more than 17 stories tall, 3.6 meters (m) in diameter and weighs 725,000 kilograms (kg). While the SLS booster appears similar to the shuttle booster, it incorporates several changes. The additional propellant segment provides additional booster performance. Parachutes and other hardware associated with recovery operations have been deleted and the booster designated as expendable for affordability reasons. The new motor incorporates new avionics, new propellant grain, asbestos-free case insulation, a redesigned nozzle, streamlined manufacturing

  1. Mode-Locking in Broad-Area Semiconductor Lasers Enhanced by Picosecond-Pulse Injection

    OpenAIRE

    Kaiser, J; Fischer, I; Elsasser, W; Gehrig, E; Hess, O

    2004-01-01

    We present combined experimental and theoretical investigations of the picosecond emission dynamics of broad-area semiconductor lasers (BALs). We enhance the weak longitudinal self-mode-locking that is inherent to BALs by injecting a single optical 50-ps pulse, which triggers the output of a distinct regular train of 13-ps pulses. Modeling based on multimode Maxwell-Bloch equations illustrates how the dynamic interaction of the injected pulse with the internal laser field efficiently couples ...

  2. Using PS-InSAR to detect surface deformation in geothermal areas of West Java in Indonesia

    Science.gov (United States)

    Maghsoudi, Yasser; van der Meer, Freek; Hecker, Christoph; Perissin, Daniele; Saepuloh, Asep

    2018-02-01

    In this paper, the Persistent Scatterer InSAR (PS-InSAR) technique is applied in order to investigate the ground deformation in and around two geothermal areas in West Java, Indonesia. Two time-series of ALOS PALSAR and Sentinel-1A acquisitions, covering the period from 2007 to 2009 and 2015-2016, are analysed. The first case study examines the Wayang Windu geothermal zone where the PS-InSAR analysis provides an overview of the surface deformation around a geothermal reservoir. Uplift is observed around the injection wells in the area. The second example involves the use of the PS-InSAR technique over a more recent geothermal system in Patuha field. Again, a pattern of uplift was observed around the only available injection well in the area. Due to the dense vegetation coverage of the geothermal areas in West Java, the longer wavelength ALOS PALSAR data is provides better results by identifying a larger number of PS points. Additionally, experiments have been carried out to compare the resulting deformation with another example of the fluid migration process i.e. water extraction in Bandung basin. The potential of sentinel-1A and ALOS PALSR data are compared in all the experiments.

  3. 47 CFR 74.1233 - Processing FM translator and booster station applications.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Processing FM translator and booster station... SERVICES FM Broadcast Translator Stations and FM Broadcast Booster Stations § 74.1233 Processing FM translator and booster station applications. (a) Applications for FM translator and booster stations are...

  4. The PrPS4 type structure and a filled variant: the compounds TbPS4 and LiEuPS4

    International Nuclear Information System (INIS)

    Joergens, S.; Alili, L.; Mewis, A.

    2005-01-01

    Colourless single crystals of TbPS 4 (a = 10.696(2), c = 19.053(4) Aa) were obtained by reaction of the elements (750 C; 30 h). The compound crystallizes with the PrPS 4 type structure (I4 1 /acd; Z = 16). The structure consists of isolated PS 4 tetrahedra each surrounded by four Tb 3+ cations. Both crystallographically different Tb 3+ cations are coordinated by eight sulfur atoms which are part of four PS 4 tetrahedra. Orange single crystals of LiEuPS 4 (a = 11.498(2), c = 19.882(4) Aa) were prepared by reaction of Eu and P with Li 2 S 4 (700 C; 20 h). The crystal structure corresponds to the PrPS 4 type, in which tubes running along [001] are occupied by Li atoms, which are surrounded by four S atoms in strongly distorted tetrahedra. LiS 4 and PS 4 tetrahedra are connected via common edges into alternating chains. (orig.)

  5. Superconducting racetrack booster for the ion complex of MEIC

    Energy Technology Data Exchange (ETDEWEB)

    Filatov, Yu [Joint Inst. for Nuclear Research (JINR), Dubna (Russian Federation); Moscow Inst. of Physics and Technology (MIPT), Moscow (Russian Federation); Kondratenko, A. M. [Science and Technique Laboratory ' Zaryad' , 630090, Novosibirsk, Russia; Kondratenko, M. A. [Science and Technique Laboratory ' Zaryad' , 630090, Novosibirsk, Russia; Kovalenko, A. [Joint Inst. for Nuclear Research (JINR), Dubna (Russian Federation); Derbenev, Yaroslav S. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Lin, Fanglei [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Morozov, Vasiliy S. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Zhang, Yuhong [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2016-02-01

    The current design of the Medium-energy Electron-Ion Collider (MEIC) project at Jefferson lab features a single 8 GeV/c figure-8 booster based on super-ferric magnets. Reducing the circumference of the booster by switching to a racetrack design may improve its performance by limiting the space charge effect and lower its cost. We consider problems of preserving proton and deuteron polarizations in a superconducting racetrack booster. We show that using magnets based on hollow high-current NbTi composite superconducting cable similar to those designed at JINR for the Nuclotron guarantees preservation of the ion polarization in a racetrack booster up to 8 GeV/c. The booster operation cycle would be a few seconds that would improve the operating efficiency of the MEIC ion complex.

  6. Object-oriented programming techniques for the AGS Booster

    International Nuclear Information System (INIS)

    Skelly, J.F.

    1991-01-01

    The applications software developed for the control system of the AGS Booster Project was written in the object-oriented language, C++. A the start of the Booster Project, the programming staff of the AGS Controls Section comprised some dozen programmer/analysts, all highly fluent in C but novices in C++. During the coarse of this project, nearly the entire staff converted to using C++ for a large fraction of their assignments. Over 100 C++ software modules are now available for Booster and general AGS use, of which a large fraction are broadly applicable tools. The transition from C to C++ from a managerial perspective is discussed and an overview is provided of the ways in which object classes have been applied in Booster software development

  7. Object-oriented programming techniques for the AGS Booster

    International Nuclear Information System (INIS)

    Skelly, J.F.

    1992-01-01

    The applications software developed for the control system of the AGS Booster Project was written in the object-oriented language, C++. At the start of the Booster Project, the programming staff of the AGS Controls Section comprised some dozen programmer/analysts, all highly fluent in C but novices in C++. During the course of this project, nearly the entire staff converted to using C++ for a large fraction of their assignments. Over 100 C++ software modules are now available both for Booster and general AGS use, of which a large fraction are broadly applicable tools. The transition from C to C++ from a managerial perspective is discussed and an overview is provided of the ways in which object classes have been applied in Booster software development. (author)

  8. General man-machine interface used in accelerators controls

    International Nuclear Information System (INIS)

    Boutheon, M.; Di Maio, F.; Pace, A.

    1992-01-01

    A large community is now using Workstations as Accelerators Computer Controls Interface, through the concepts of windows - menus - synoptics - icons. Some standards were established for the CERN-PS control systems rejuvenation. The Booster-to-PS transfer and injection process is now entirely operated with these tools. This application constitutes a global environment providing the users with the controls, analysis, visualization of a part of an accelerator. Individual commands, measurements, and specialized programs including complex treatments are available in a homogeneous frame. Some months of experience in current operation have shown that this model can be extended to the whole project. (author)

  9. Power flow control using quadrature boosters

    Science.gov (United States)

    Sadanandan, Sandeep N.

    A power system that can be controlled within security constraints would be an advantage to power planners and real-time operators. Controlling flows can lessen reliability issues such as thermal limit violations, power stability problems, and/or voltage stability conditions. Control of flows can also mitigate market issues by reducing congestion on some lines and rerouting power to less loaded lines or onto preferable paths. In the traditional control of power flows, phase shifters are often used. More advanced methods include using Flexible AC Transmission System (FACTS) Controllers. Some examples include Thyristor Controlled Series Capacitors, Synchronous Series Static Compensators, and Unified Power Flow Controllers. Quadrature Boosters (QBs) have similar structures to phase-shifters, but allow for higher voltage magnitude during real power flow control. In comparison with other FACTS controllers QBs are not as complex and not as expensive. The present study proposes to use QBs to control power flows on a power system. With the inclusion of QBs, real power flows can be controlled to desired scheduled values. In this thesis, the linearized power flow equations used for power flow analysis were modified for the control problem. This included modifying the Jacobian matrix, the power error vector, and calculating the voltage injected by the quadrature booster for the scheduled real power flow. Two scenarios were examined using the proposed power flow control method. First, the power flow in a line in a 5-bus system was modified with a QB using the method developed in this thesis. Simulation was carried out using Matlab. Second, the method was applied to a 30-bus system and then to a 118-bus system using several QBs. In all the cases, the calculated values of the QB voltages led to desired power flows in the designated line.

  10. The AGS Booster control system

    International Nuclear Information System (INIS)

    Frankel, R.; Auerbach, E.; Culwick, B.; Clifford, T.; Mandell, S.; Mariotti, R.; Salwen, C.; Schumburg, N.

    1988-01-01

    Although moderate in size, the Booster construction project requires a comprehensive control system. There are three operational modes: as a high intensity proton injector for the AGS, as a heavy ion accelerator and injector supporting a wide range of ions and as a polarized proton storage injector. These requirements are met using a workstation based extension of the existing AGS control system. Since the Booster is joining a complex of existing accelerators, the new system will be capable of supporting multiuser operational scenarios. A short discussion of this system is discussed in this paper

  11. Beam instrumentation in the AGS Booster

    International Nuclear Information System (INIS)

    Witkover, R.L.

    1991-01-01

    The AGS Booster was designed to accelerate low intensity (2 x 10 10 ) polarized protons, high intensity (1.5x10 13 ) protons and heavy ions through Au +33 . Coping with this wide range of beams, the 3 x 10 -11 Torr vacuum and the radiation environment presented challenges for the beam monitors. Some of the more interesting instrumentation design and performance during the recent Booster proton commissioning will be described

  12. Primary and booster vaccination with DTPw-HB/Hib pentavalent vaccine in Costa Rican children who had received a birth dose of hepatitis B vaccine

    Directory of Open Access Journals (Sweden)

    Idis Faingezicht

    2002-10-01

    Full Text Available Objective. The DTPw-HB/Hib pentavalent combination vaccine has been developed following recommendations of the World Health Organization for the introduction of hepatitis B (HB and Haemophilus influenzae type b (Hib vaccines into routine childhood vaccination programs. The objectives of this study were to: 1 analyze the immunogenicity and the reactogenicity of the DTPw-HB/Hib pentavalent combination vaccine in comparison to separate injections of DTPw-HB and Hib vaccines as primary vaccination in a group of children who had received a dose of HB vaccine at birth and 2 in the second year of life to assess the antibody persistence as well as the response to a DTPw-HB/Hib or DTPw/Hib booster. Methods. In the first part of the study (primary-vaccination stage, conducted in 1998-1999, we analyzed the immunogenicity and reactogenicity of the DTPw-HB/Hib combination vaccine in comparison to separate injections of DTPw-HB and Hib vaccines as primary vaccination at 2, 4, and 6 months of age in 207 Costa Rican children who had received a dose of HB vaccine at birth. Later, in the booster-vaccination stage of the study, in 1999-2000, in a subset of the children (69 toddlers, now 15-18 months old, antibody persistence was measured, and response to a DTPw-HB/Hib or DTPw/Hib booster was also assessed. Results. In both primary-vaccination groups, at least 97.5% of the infants reached protective levels of antibodies (seropositivity against the antigens employed in the vaccines. The DTPw-HB/Hib pentavalent combination vaccine did not result in more local reactions than did the DTPw-HB vaccine alone, and, in terms of general reactions, there was no clinically significant difference between the combination or separate injections, and with the pentavalent vaccine having the benefit of needing one less injection. Nine months after the third dose of the primary-vaccination course, antibody persistence was similar in both groups, with over 93% of children still having

  13. Booster Vaccination: The Role of Reduced Antigen Content Vaccines as a Preschool Booster

    Directory of Open Access Journals (Sweden)

    Giovanni Gabutti

    2014-01-01

    Full Text Available The need for boosters for tetanus, diphtheria, pertussis, and polio, starting from preschool age, is related to the waning immune protection conferred by vaccination, the elimination/reduction of natural boosters due to large-scale immunization programs, and the possibility of reintroduction of wild agents from endemic areas. Taking into account the relevance of safety/tolerability in the compliance with vaccination among the population, it have been assessed whether today enough scientific evidences are available to support the use of dTap-IPV booster in preschool age. The review of the literature was conducted using the PubMed search engine. A total of 41 works has been selected; besides, the documentation produced by the World Health Organization, the European Centre for Disease Control, and the Italian Ministry of Health has been consulted. Many recent papers confirm the opportunity to use a low antigenic dose vaccine starting from 4 to 6 years of age. There is also evidence that 10 years after immunization the rate of seroprotected subjects against diphtheria does not differ significantly between those vaccinated with paediatric dose (DTaP or reduced dose (dTaP or dTap product. The dTpa vaccine is highly immunogenic for diphtheria toxoids regardless of prior vaccination history (2 + 1 and 3 + 1 schedules.

  14. Subcriticality determination in ADS: Valina-Booster experiments

    International Nuclear Information System (INIS)

    Persson, C. M.; Gudowski, W.; Fokau, A.; Bournos, V.; Fokov, Y.; Routkovskaia, C.; Serafimovich, I.; Kiyavitskaya, H.

    2007-01-01

    A major problem in operating a full-scale subcritical accelerator-driven system (ADS) is to ensure sufficient margin to criticality. Therefore, reliable techniques for subcriticality monitoring are required. In order to develop such techniques, a full understanding of existing reactivity determination methods is essential. In this work, reactivity determination methods, such as pulsed neutron source methods and noise methods, are studied experimentally in the subcritical facility YALINA-Booster. YALINA-Booster: The subcritical assembly YALINA-Booster: recently constructed at the Joint Institute for Power and Nuclear Research - Sosny, consists of a subcritical core driven by an external neutron source. The neutron source is a powerful neutron generator consisting of a deuteron accelerator and a target of deuterium or tritium embedded in titanium. Through (d, d) - or (d, t)-reactions neutrons are created with energy around 2.5 MeV and 14.1 MeV respectively. Neutrons are born in the centre of the core and multiply through a lead matrix fuelled with highly enriched uranium (90% and 36%). This zone is referred to as the booster zone and is surrounded by a thermal zone, moderated by polyethylene. In order to reach sufficient high effective multiplication factor, the thermal zone is fuelled by approximately one thousand rods of 10% enriched uranium dioxide in cylindrical geometry. To prevent thermal neutrons from diffusing into the fast booster zone, an interface, consisting of boron carbide and natural uranium rods, is located between the zones. YALINA-Booster has a radial graphite reflector of thickness 24 cm. Experiments: Experiments using the neutron source in pulsed mode will be presented, relying on methods such as the area method and the method of prompt neutron decay rate determination. Moreover, results from noise analysis using for instance the Feynman-α method will be presented

  15. Machine development studies for PSB extraction at 160 MeV and PSB to PS beam transfer

    CERN Document Server

    Forte, V; Bartmann, W; Borburgh, J; Ferrero Colomo, A; Damerau, H; Di Giovanni, G P; Coralejo Feliciano, L M; Fraser, M A; Gamba, D; Mikulec, B; Guerrero Ollacarizqueta, A; Serluca, M; Sermeus, L; Sterbini, G

    2017-01-01

    This paper collects the machine development (MD) activities for the beam transfer studies in 2016 concerning the PSB extraction and the PSB-to-PS transfer. Many topics are covered: from the 160 MeV extraction from the PSB, useful for the future commissioning activities after the connection with Linac4, to new methodologies for measuring the magnetic waveforms of kickers and dispersion reduction schemes at PS injection, which are of great interest for the LHC Injectors Upgrade (LIU) [1] project.

  16. Operational status of the AGS Booster Main Ring Magnet Power Supply

    International Nuclear Information System (INIS)

    Soukas, A.; Bannon, M.; Geller, J.; McNerney, A.J.; Sandberg, J.; Toldo, F.; Zhang, S.Y.

    1992-01-01

    The Booster is a multipurpose accelerator interposed between a 200 MeV linac, a pair of 15 MV Tandem Van deGraaf accelerators, and the AGS. It can operate on slow cycles of 0.3 Hertz pulse repetition frequency up to a maximum of 7.5 Hertz. The different cycles, from long front porches for long injection or accumulation periods or flattops for slow extraction, to normal fast extraction cycles, accommodate protons, heavy ions (h.i.) and polarized protons. One of the systems enabling the flexible Booster operation is the Main Ring Magnet Power Supply (MRPS) system. It consist of a series connection of six, 1000 volt, multiphase rectifiers together with by pass switches. Two of the six operate at currents up to 6 kA and the rest up to 3 kA. All bypass switches are rated for 6 kA. The system is equipped with passive, damped LCRC filters as well as an active transformer coupled correction system. The MRPS is connected directly to the Long Island 69 Kv bus via a dedicated 20 MVA transformer. The choice of a series of modules enables the very flexible cycle generation and at the same time minimizes the deleterious effects of power factor and harmonics on the ac lines

  17. An overview of Booster and AGS Polarized Proton Operations during Run 17

    Energy Technology Data Exchange (ETDEWEB)

    Zeno, K. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-10-11

    There were only a few differences in the setup between this year’s Polarized Proton run and the previous one (Run 15). Consequently, this note will focus on these differences as well as a few more notable studies done during the course of the run. This year, the Booster input intensity was kept around 7e11 for the majority of the run whereas in Run 15 it was kept around 9e11. It was lowered because there was some indication that the source polarization was higher with this lower input. Some of the polarization measurements that motivated this change will be discussed. Both the emittance and polarization on the AGS flattop show intensity dependence, thought to be related to the peak current, especially early in the AGS acceleration ramp. In Run 15, the AGS Rf was configured for h=8, but in this run h=6 was used to reduce the peak current and also to allow for the possibility of using a dual harmonic to reduce it further. Eventually, a dual harmonic configuration was used for the first 100 ms or so of the AGS acceleration cycle. Two cavities were set to h=12 and phased differently than the other 8 to accomplish this. Quad pumping was also used at Booster extraction to make the bunch injected into the AGS wider in order to match the dual harmonic bucket right at injection. This configuration, which was used for the majority of the run, will be described. Measurements of the intensity dependence of the transverse emittance and polarization with and without it will be compared.

  18. Status of the maintenance for the KEK 12GEV-PS main ring and power supply

    International Nuclear Information System (INIS)

    Sato, Hikaru; Igarashi, Susumu; Marutsuka, Katsumi; Mikawa, Katsuhiko; Shirakata, Masashi; Sueno, Tsuyoshi; Tokuda, Noboru

    2004-01-01

    More than 30 years passed since the KEK 12GeV-PS construction, some of accelerator equipments are highly radiated, especially the injection and the extraction equipments. In recent years, the higher intensity beam has been required for such as the long baseline neutrino oscillation experiment and rare decay experiments. Then, the circumference of the maintenance work has become severe. Further, almost equipments of main ring and power supply have deteriorated. Status of the Maintenance for the KEK 12GeV-PS main ring and power supply are presented. (author)

  19. Petawatt laser system for the fast ignition studies at ILE, Osaka University

    International Nuclear Information System (INIS)

    Izawa, Y.

    2002-01-01

    We have developed a PW Nd:glass laser system, which can deliver 1 PW output with 500 J in 0.5 ps, to study a fast ignitor concept in laser fusion. In the front end of this system, the optical parametric chirped-pulse amplifier (OPCPA) was introduced. The OPCPA solves several problems arising in an existing Ti:sapphire regenerative amplifier, such as low single-pass gain, high prepulse and output fluctuation. A booster amplifier is a Cassegrain-type three pass disk system having a 350 mm clear aperture, which generated 1.1 kJ output energy with the spectral width of 3.7 nm corresponding to 0.5 ps in Fourier transform limited pulse. The spatial phase aberration mainly caused in the booster amplifier is corrected using a deformable mirror. The laser pulse is compressed by a pair of 1-m diffraction gratings and focused by a parabolic mirror. The timing jitter between PW laser and GEKKO XII is less than 10 ps, which was attained by injecting a weak pulse splitted out from the front end into the preamplifier of GEKKO XII. (author)

  20. Feasibility study of a 2 GeV superconducting $H^{-}$ linac as injector for the CERN PS

    CERN Document Server

    Garoby, R; Hill, C E; Lombardi, A M; Ostroumov, P N; Tessier, J M; Vretenar, Maurizio

    1998-01-01

    This preliminary feasibility study is based on the availability of the CERN LEP2 superconducting RF system after LEP de-commissioning. The option that is explored is to use this system as part of a high energy H- linac injecting at 2 GeV into the CERN PS, with the aim of reliably providing at its output twice the presently foreseen transverse beam brightness at the ultimate intensity envisaged for LHC. This requires the linac to be pulsed at the PS repetition rate of 0.8 Hz with a mean beam current of 10 mA which is sufficient for filling the PS in 240 ms (i.e. about 100 turns) with the ultimate intensity foreseen for injection for the LHC. The linac is composed of two RFQs with a chopping section, a room temperature DTL, a superconducting section with reduced beta cavities up to 1 GeV, and a section of LEP2 cavities up to 2 GeV. This study deals, in particular, with the problems inherent in H- acceleration up to high energy and in the pulsed operation of SC cavities. Means for compensating microphonic vibrat...

  1. Space shuttle booster separation motor design

    Science.gov (United States)

    Smith, G. W.; Chase, C. A.

    1976-01-01

    The separation characteristics of the space shuttle solid rocket boosters (SRBs) are introduced along with the system level requirements for the booster separation motors (BSMs). These system requirements are then translated into specific motor requirements that control the design of the BSM. Each motor component is discussed including its geometry, material selection, and fabrication process. Also discussed is the propellant selection, grain design, and performance capabilities of the motor. The upcoming test program to develop and qualify the motor is outlined.

  2. The AGS Booster main ring power supply system

    International Nuclear Information System (INIS)

    Soukas, A.; Hughes, K.; Sandberg, J.; Toldo, F.; Zhang, S.Y.

    1989-01-01

    The AGS Booster is being designed as a very versatile particle accelerator. Its primary function is to be a high quality injector to the currently operating Alternating Gradient Synchrotron (AGS). The Booster/AGS combination will produce proton intensities greater than 5 x 10 13 protons per pulse (ppp), and accelerate heavy ions, with mass up to 200, to a maximum energy of 15 GeV per atomic mass unit (GeV/amu). The power supply for the Booster Main Ring (BMRPS) has to accommodate a wide range of cycles and a wide range of operating parameters. The cycles range from storage for several seconds to rapid cycling at 7.5 Hz. The peak output power is 18 MW. This paper will describe the AGS Booster machine powering requirements, the choice of power supply, the a.c. circuit tie-in and its associated problems and some of the details of the design of the BMRPS. 9 refs., 2 figs

  3. Pathway analysis of systemic transcriptome responses to injected polystyrene particles in zebrafish larvae.

    Science.gov (United States)

    Veneman, Wouter J; Spaink, Herman P; Brun, Nadja R; Bosker, Thijs; Vijver, Martina G

    2017-09-01

    Microplastics are a contaminant of emergent concern in the environment, however, to date there is a limited understanding on their movement within organisms and the response of organisms. In the current study zebrafish embryos at different development stages were exposed to 700nm fluorescent polystyrene (PS) particles and the response pathway after exposure was investigated using imaging and transcriptomics. Our results show limited spreading of particles within the larvae after injection during the blastula stage. This is in contrast to injection of PS particles in the yolk of 2-day old embryos, which resulted in redistribution of the PS particles throughout the bloodstream, and accumulation in the heart region. Although injection was local, the transcriptome profiling showed strong responses of zebrafish embryos exposed to PS particle, indicating a systemic response. We found several biological pathways activated which are related to an immune response in the PS exposed zebrafish larvae. Most notably the complement system was enriched as indicated by upregulation of genes in the alternative complement pathway (e.g. cfhl3, cfhl4, cfb and c9). The fact that complement pathway is activated indicates that plastic microparticles are integrated in immunological recognition processes. This was supported by fluorescence microscopy results, in which we observed co-localisation of neutrophils and macrophages around the PS particles. Identifying these key events can be a first building block to the development of an adverse outcome pathway (AOP). These data subsequently can be used within ecological and human risk assessment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Cold chain and virus-free chloroplast-made booster vaccine to confer immunity against different poliovirus serotypes.

    Science.gov (United States)

    Chan, Hui-Ting; Xiao, Yuhong; Weldon, William C; Oberste, Steven M; Chumakov, Konstantin; Daniell, Henry

    2016-11-01

    The WHO recommends complete withdrawal of oral polio vaccine (OPV) type 2 by April 2016 globally and replacing with at least one dose of inactivated poliovirus vaccine (IPV). However, high-cost, limited supply of IPV, persistent circulating vaccine-derived polioviruses transmission and need for subsequent boosters remain unresolved. To meet this critical need, a novel strategy of a low-cost cold chain-free plant-made viral protein 1 (VP1) subunit oral booster vaccine after single IPV dose is reported. Codon optimization of the VP1 gene enhanced expression by 50-fold in chloroplasts. Oral boosting of VP1 expressed in plant cells with plant-derived adjuvants after single priming with IPV significantly increased VP1-IgG1 and VP1-IgA titres when compared to lower IgG1 or negligible IgA titres with IPV injections. IgA plays a pivotal role in polio eradication because of its transmission through contaminated water or sewer systems. Neutralizing antibody titres (~3.17-10.17 log 2 titre) and seropositivity (70-90%) against all three poliovirus Sabin serotypes were observed with two doses of IPV and plant-cell oral boosters but single dose of IPV resulted in poor neutralization. Lyophilized plant cells expressing VP1 stored at ambient temperature maintained efficacy and preserved antigen folding/assembly indefinitely, thereby eliminating cold chain currently required for all vaccines. Replacement of OPV with this booster vaccine and the next steps in clinical translation of FDA-approved antigens and adjuvants are discussed. © 2016 The Authors. Plant Biotechnology Journal published by Society for Experimental Biology and The Association of Applied Biologists and John Wiley & Sons Ltd.

  5. 1170-MW(t) HTGR-PS/C plant application study report: heavy oil recovery application

    International Nuclear Information System (INIS)

    Rao, R.; McMain, A.T. Jr.

    1981-05-01

    This report describes the application of a high-temperature gas-cooled reactor (HTGR) which operates in a process steam/cogeneration (PS/C) mode in supplying steam for enhanced recovery of heavy oil and in exporting electricity. The technical and economic merits of an 1170-MW(t) HTGR-PS/C are compared with those of coal-fired plants and (product) oil-fired boilers for this application. The utility requirements for enhanced oil recovery were calculated by establishing a typical pattern of injection wells and production wells for an oil field similar to that of Kern County, California. The safety and licensing issues of the nuclear plant were reviewed, and a comparative assessment of the alternative energy sources was performed. Technically and economically, the HTGR-PS/C plant has attractive merits. The major offsetting factors would be a large-scale development of a heavy oil field by a potential user for the deployment of a 1170-MW(t) HTGR-PS/C; plant and the likelihood of available prime heavy oil fields for the mid-1990 operation

  6. Booster phenomenon of QuantiFERON-TB Gold after prior intradermal PPD injection.

    Science.gov (United States)

    Igari, H; Watanabe, A; Sato, T

    2007-07-01

    University medical school in Japan. To clarify the influence of prior intradermal purified protein derivative (PPD) injection on QuantiFERON-TB Gold (QFT-G). Ninety-seven sixth-year university medical students aged 20-29 years concurrently underwent QFT-G and tuberculin skin test (TST). The first negative QFT-G and the first TST boost QFT-G. Further studies of the diagnostic significance and immunological mechanisms of this phenomenon are needed. For clinical application, especially during contact screening, QFT-G should be evaluated while keeping in mind the possible influence of prior PPD intradermal injection.

  7. An efficiency booster for energy conversion in natural circulation loops

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Dongqing, E-mail: wangdongqing@stu.xjtu.edu.cn [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an, Shaanxi 710049 (China); Beijing Computational Science Research Center, Beijing 100084 (China); Jiang, Jin, E-mail: jjiang@eng.uwo.ca [Department of Electrical and Computer Engineering, The University of Western Ontario, London, Ontario N6A 5B9 (Canada); Beijing Computational Science Research Center, Beijing 100084 (China)

    2016-08-01

    Highlights: • Low driving power conversion efficiency of natural circulation loops is proved. • The low conversion efficiency leads to low heat transfer capacity of such loops. • An efficiency booster is designed with turbine to increase the efficiency. • Performance of the proposed booster has been numerically simulated. • The booster drastically enhances heat transfer capacity of such loops. - Abstract: In this paper, the capacity of a natural circulation loop for transferring heat from a heat source to a heat sink has been analyzed. It is concluded that the capacity of the natural circulation loop depends on the conversion efficiency of the thermal energy from the heat source to the driving force for the circulation of the flow. The low conversion efficiency leading to weak driving force in such loops has been demonstrated analytically and validated through simulation results. This issue has resulted in a low heat transfer capacity in the circulation loop. To increase the heat transfer capacity, one has to improve this efficiency. To meet such a need, a novel efficiency booster has been developed in this paper. The booster essentially increases the flow driving force and hence significantly improves the overall heat transfer capacity. Design and analysis of this booster have been performed in detail. The performance has been examined through extensive computer simulations. It is concluded that the booster can indeed drastically improve the heat transfer capacity of the natural circulation loop.

  8. An efficiency booster for energy conversion in natural circulation loops

    International Nuclear Information System (INIS)

    Wang, Dongqing; Jiang, Jin

    2016-01-01

    Highlights: • Low driving power conversion efficiency of natural circulation loops is proved. • The low conversion efficiency leads to low heat transfer capacity of such loops. • An efficiency booster is designed with turbine to increase the efficiency. • Performance of the proposed booster has been numerically simulated. • The booster drastically enhances heat transfer capacity of such loops. - Abstract: In this paper, the capacity of a natural circulation loop for transferring heat from a heat source to a heat sink has been analyzed. It is concluded that the capacity of the natural circulation loop depends on the conversion efficiency of the thermal energy from the heat source to the driving force for the circulation of the flow. The low conversion efficiency leading to weak driving force in such loops has been demonstrated analytically and validated through simulation results. This issue has resulted in a low heat transfer capacity in the circulation loop. To increase the heat transfer capacity, one has to improve this efficiency. To meet such a need, a novel efficiency booster has been developed in this paper. The booster essentially increases the flow driving force and hence significantly improves the overall heat transfer capacity. Design and analysis of this booster have been performed in detail. The performance has been examined through extensive computer simulations. It is concluded that the booster can indeed drastically improve the heat transfer capacity of the natural circulation loop.

  9. New beam instrumentation in the AGS Booster

    International Nuclear Information System (INIS)

    Witkover, R.L.

    1991-01-01

    The AGS Booster was designed to accelerate beams from 2x10 10 polarized protons to 1.5x10 13 protons and heavy ions through Au +33 . The range of beam parameters and the high vacuum, and radiation environment presented challenges for the beam instrumentation. Some interesting beam monitors in the Booster and transport lines, will be described. Where available, results will be presented. 21 refs., 7 figs

  10. COLLECTIVE EFFECTS AT INJECTION FOR THE APS-U MBA LATTICE

    Energy Technology Data Exchange (ETDEWEB)

    Lindberg, R.; Borland, M.; Blednykh, A.

    2017-06-25

    The Advanced Photon Source has proposed an upgrade to a multi-bend achromat (MBA) with a proposed timing mode calls for 48 bunches of 15 nC each. In this mode of operation we find that phase space mismatch from the booster can drive large wakefields that in turn may limit the current below that of the nominal collective instability threshold. We show that collective effects at injection lead to emittance growth that makes usual off-axis accumulation very challenging. On-axis injection ameliorates many of these issues, but we find that transverse feedback is still required. We explore the role of impedance, feedback, and phase-space mismatch on transverse instabilities at injection.

  11. Weak Depolarizing Resonances in the 3-TeV VLHC Booster

    International Nuclear Information System (INIS)

    Anferov, V.A.

    1999-01-01

    The possibility of polarized-proton-beam acceleration in the proposed low-field 3-TeV VLHC booster is considered. We find that the low-field combined function magnets in the booster's long FODO cells cause an inadvertent cancellation of most depolarizing fields due to a mechanism suggested earlier by Chao and Derbenev [Part.Accel.36, 25 (1991)]. The strongest spin-depolarizing resonances in the 3-TeV booster seem to be similar in strength to those in the 250-GeV RHIC. Moreover, the strength of the 3-TeV booster's strongest intrinsic depolarizing resonances decreases with energy, in contrast with the energy growth of the depolarizing resonance's strength in most proton synchrotrons. copyright 1999 The American Physical Society

  12. Diamond Light Source Booster fast orbit feedback system

    International Nuclear Information System (INIS)

    Gayadeen, S.; Duncan, S.R.; Christou, C.; Heron, M.T.; Rowland, J.

    2012-01-01

    The Fast Orbit Feedback system that has been installed on the Diamond Light Source Storage ring has been replicated on the Booster synchrotron in order to provide a test bed for the development of the Storage Ring controller design. To realise this the Booster is operated in DC mode. The electron beam is regulated in two planes using the Fast Orbit Feedback system, which takes the beam position from 22 beam position monitors for each plane, and calculates offsets to 44 corrector power supplies at a sample rate of 10 kHz. This paper describes the design and realization of the controller for the Booster Fast Orbit Feedback, presents results from the implementation and considers future development

  13. Feedback correction of injection errors using digital signal-processing techniques

    Directory of Open Access Journals (Sweden)

    N. S. Sereno

    2007-01-01

    Full Text Available Efficient transfer of electron beams from one accelerator to another is important for 3rd-generation light sources that operate using top-up. In top-up mode, a constant amount of charge is injected at regular intervals into the storage ring to replenish beam lost primarily due to Touschek scattering. Top-up therefore requires that the complex of injector accelerators that fill the storage ring transport beam with a minimum amount of loss. Injection can be a source of significant beam loss if not carefully controlled. In this note we describe a method of processing injection transient signals produced by beam-position monitors and using the processed data in feedback. Feedback control using the technique described here has been incorporated in the Advanced Photon Source (APS booster synchrotron to correct injection transients.

  14. Oak Ridge isochronous cyclotron as an energy booster for a 25 MV tandem

    International Nuclear Information System (INIS)

    Lord, R.S.; Hudson, E.D.; McNeilly, G.S.

    1975-01-01

    The maximum heavy-ion energy available at Oak Ridge will be substantially increased by using ORIC as an energy booster for the 25 MV ''folded'' tandem now being acquired. Beams of ions with mass up to A = 160, with energy sufficient to overcome the Coulomb barrier on lead, will be produced. The beams will enter the cyclotron through the dee stem and will be directed by a magnet through the fringe and main fields to a stripping foil which lies on the appropriate orbit for acceleration. General orbit and beam transport codes were used to aid in the design of the injection system. (U.S.)

  15. New beam instrumentation in the AGS Booster

    Energy Technology Data Exchange (ETDEWEB)

    Witkover, R.L.

    1991-01-01

    The AGS Booster was designed to accelerate beams from 2{times}10{sup 10} polarized protons to 1.5{times}10{sup 13} protons and heavy ions through Au{sup +33}. The range of beam parameters and the high vacuum, and radiation environment presented challenges for the beam instrumentation. Some interesting beam monitors in the Booster and transport lines, will be described. Where available, results will be presented. 21 refs., 7 figs.

  16. Performance evaluation of DAAF as a booster material using the onionskin test

    Energy Technology Data Exchange (ETDEWEB)

    Morris, John S [Los Alamos National Laboratory; Francois, Elizabeth G [Los Alamos National Laboratory; Hooks, Daniel E [Los Alamos National Laboratory; Hill, Larry G [Los Alamos National Laboratory; Harry, Herbert H [Los Alamos National Laboratory

    2010-12-02

    Initiation of insensitive high explosive (IHE) formulations requires the use of a booster explosive in the initiation train. Booster material selection is crucial, as the initiation must reliably function across some spectrum of physical parameters. The interest in Diaminoazoxyfurazan (DAAF) for this application stems from the fact that it possesses many traits of an IHE but is shock sensitive enough to serve as an explosive booster. A hemispherical wave breakout test, termed the onionskin test, is one of the methods used to evaluate the performance of a booster material. The wave breakout time-position history at the surface of a hemispherical IHE charge is recorded and the relative uniformity of the breakout can be quantitatively compared between booster materials. A series of onionskin tests were performed to investigate breakout and propagation diaminoazoxyfurazan (DAAF) at low temperatures to evaluate ignition and detonation spreading in comparison to other explosives commonly used in booster applications. Some wave perturbation was observed with the DAAF booster in the onionskin tests presented. The results of these tests will be presented and discussed.

  17. Booster Main Engine Selection Criteria for the Liquid Fly-Back Booster

    Science.gov (United States)

    Ryan, Richard M.; Rothschild, William J.; Christensen, David L.

    1998-01-01

    The Liquid Fly-Back Booster (LFBB) Program seeks to enhance the Space Shuttle system safety performance and economy of operations through the use of an advanced, liquid propellant Booster Main Engine (BME). There are several viable BME candidates that could be suitable for this application. The objective of this study was to identify the key criteria to be applied in selecting among these BME candidates. This study involved an assessment of influences on the overall LFBB utility due to variations in the candidate rocket engines' characteristics. This includes BME impacts on vehicle system weight, perfortnance,design approaches, abort modes, margins of safety, engine-out operations, and maintenance and support concepts. Systems engineering analyses and trade studies were performed to identify the LFBB system level sensitivities to a wide variety of BME related parameters. This presentation summarizes these trade studies and the resulting findings of the LFBB design teams regarding the BME characteristics that most significantly affect the LFBB system. The resulting BME choice should offer the best combination of reliability, performance, reusability, robustness, cost, and risk for the LFBB program.

  18. Determination of grafting conversion degree in PS/PS-graft-POSS/POSS hybrid nanocomposites obtained through reactive processing

    International Nuclear Information System (INIS)

    Bianchi, Otavio; Repenning, Gustavo B.; Mauler, Raquel S.; Oliveira, Ricardo V.B.; Canto, Leonardo B.

    2011-01-01

    Hybrid nanocomposites of polystyrene (PS) and polyhedral oligomeric silsesquioxanes (POSS) - PS/PS-graft-POSS/POSS - with different grafting degrees were prepared by reactive melt processing using dicumyl peroxide (DCP) as initiator in the presence or absence of styrene monomer as radical transfer agent. Gel permeation chromatography (GPC) using triple-detector and proton nuclear magnetic resonance (NMR 1 H) analyses were used together to determine the conversion degree of PS-graft-POSS as a function of the reactive processing conditions adopted. GPC was employed to evaluate the effects of grafting (PS-graft-POSS) and PS chains degradation (β scission) that occur simultaneously during processing on the variation of average molecular masses and distributions for each PS/POSS sample. PS/POSS systems processed with styrene showed higher weight average molecular weights (M w ) and lower polydispersity indexes (M w /M n ), as a result of higher grafting (PS-graft-POSS) conversion (28-40%) and lower PS chain degradation level, as compared to PS/POSS systems processed without styrene in which the degree of grafting conversion was around 25-28%. (author)

  19. Space Launch System Accelerated Booster Development Cycle

    Science.gov (United States)

    Arockiam, Nicole; Whittecar, William; Edwards, Stephen

    2012-01-01

    With the retirement of the Space Shuttle, NASA is seeking to reinvigorate the national space program and recapture the public s interest in human space exploration by developing missions to the Moon, near-earth asteroids, Lagrange points, Mars, and beyond. The would-be successor to the Space Shuttle, NASA s Constellation Program, planned to take humans back to the Moon by 2020, but due to budgetary constraints was cancelled in 2010 in search of a more "affordable, sustainable, and realistic" concept2. Following a number of studies, the much anticipated Space Launch System (SLS) was unveiled in September of 2011. The SLS core architecture consists of a cryogenic first stage with five Space Shuttle Main Engines (SSMEs), and a cryogenic second stage using a new J-2X engine3. The baseline configuration employs two 5-segment solid rocket boosters to achieve a 70 metric ton payload capability, but a new, more capable booster system will be required to attain the goal of 130 metric tons to orbit. To this end, NASA s Marshall Space Flight Center recently released a NASA Research Announcement (NRA) entitled "Space Launch System (SLS) Advanced Booster Engineering Demonstration and/or Risk Reduction." The increased emphasis on affordability is evident in the language used in the NRA, which is focused on risk reduction "leading to an affordable Advanced Booster that meets the evolved capabilities of SLS" and "enabling competition" to "enhance SLS affordability. The purpose of the work presented in this paper is to perform an independent assessment of the elements that make up an affordable and realistic path forward for the SLS booster system, utilizing advanced design methods and technology evaluation techniques. The goal is to identify elements that will enable a more sustainable development program by exploring the trade space of heavy lift booster systems and focusing on affordability, operability, and reliability at the system and subsystem levels5. For this study

  20. Magnetic Retraction of Bowel by Intraluminal Injectable Cyanoacrylate-Based Magnetic Glue

    Directory of Open Access Journals (Sweden)

    Zhigang Wang

    2013-01-01

    Full Text Available Magnetic retraction offers advantages over physical retraction by graspers because of reduced tissue trauma. The objectives of this study are to investigate a novel method of magnetisation of bowel segments by intraluminal injection of magnetic glue and to demonstrate the feasibility of magnetic retraction of bowel with sufficient force during minimal access surgery. Following an initial materials characterisation study, selected microparticles of stainless steel (SS410-μPs were mixed with chosen cyanoacrylate glue (Loctite 4014. During intraluminal injection of the magnetic glue using ex vivo porcine colonic segments, a magnetic probe placed at the injected site ensured that the SS410-μPs aggregated during glue polymerisation to form an intraluminal mucosally adherent coagulum. The magnetised colonic segments were retracted by magnetic probes (5 and 10 mm placed external to the bowel wall. A tensiometer was used to record the retraction force. With an injected volume of 2 mL in a particle concentration of 1 g/mL, this technique produced maximal magnetic retraction forces of 2.24 ± 0.23 N and 5.11 ± 0.34 N (, with use of 5 and 10 mm probes, respectively. The results indicate that the formation of an intraluminal coagulum based on SS410-μPs and Loctite 4014 produces sufficient magnetic retraction for bowel retraction.

  1. The (7,7) optics at CERN PS

    CERN Document Server

    Serluca, M; Efthymiopoulos, I; Sperati, F; Sterbini, G; Tecker, F; Zisopoulos, P

    2017-01-01

    The PS lattice is composed by one hundred combinedfunction magnets, which set the bare tune of the machineto (Qh,Qv) = (6.25, 6.28). Low energy quadrupoles areused at injection to move the tune in a limited working pointarea. In particular the vertical tune is moved below 6.25 toavoid the structural resonance 8Qv= 50 coupled with spacecharge, which leads to strong losses. In view of the highdemands in terms of beam brightness for LIU and HL-LHCprojects, the interest of exploring different integer tune work-ing area started during last years. During 2016, for the firsttime, it has been possible to explore the (7,7) tune workingarea at injection using the auxiliary circuits of the combinedfunction magnets. A finite-element magnetic model, underdevelopment, has been used to predict the required currentsin order to get the desired optical parameters. In this pa-per we present the results and issues encountered duringthe Machine Development (MD) studies about the injectionin the (7,7) area along with optics and be...

  2. Booster parameter list

    International Nuclear Information System (INIS)

    Parsa, Z.

    1986-10-01

    The AGS Booster is designed to be an intermediate synchrotron injector for the AGS, capable of accelerating protons from 200 MeV to 1.5 GeV. The parameters listed include beam and operational parameters and lattice parameters, as well as parameters pertaining to the accelerator's magnets, vacuum system, radio frequency acceleration system, and the tunnel. 60 refs., 41 figs

  3. ps-ro Fuzzy Open(Closed Functions and ps-ro Fuzzy Semi-Homeomorphism

    Directory of Open Access Journals (Sweden)

    Pankaj Chettri

    2015-11-01

    Full Text Available The aim of this paper is to introduce and characterize some new class of functions in a fuzzy topological space termed as ps-ro fuzzy open(closed functions, ps-ro fuzzy pre semiopen functions and ps-ro fuzzy semi-homeomorphism. The interrelation among these concepts and also their relations with the parallel existing concepts are established. It is also shown with the help of examples that these newly introduced concepts are independent of the well known existing allied concepts.

  4. Last PS magnet refurbished

    CERN Multimedia

    2009-01-01

    PS Magnet Refurbishment Programme Completed. The 51st and final refurbished magnet was transported to the PS on Tuesday 3 February. The repair and consolidation work on the PS started back in 2003 when two magnets and a busbar connection were found to be faulty during routine high-voltage tests. The cause of the fault was a combination of age and radiation on electrical insulation. After further investigation the decision was taken to overhaul half of the PS’s 100 magnets to reduce the risk of a similar fault. As from 20 February the PS ring will start a five-week test programme to be ready for operation at the end of March.

  5. Mathematical modeling of compression processes in air-driven boosters

    International Nuclear Information System (INIS)

    Li Zeyu; Zhao Yuanyang; Li Liansheng; Shu Pengcheng

    2007-01-01

    The compressed air in normal pressure is used as the source of power of the air-driven booster. The continuous working of air-driven boosters relies on the difference of surface area between driven piston and driving piston, i.e., the different forces acting on the pistons. When the working surface area of the driving piston for providing power is greater than that of the driven piston for compressing gas, the gas in compression chamber will be compressed. On the basis of the first law of thermodynamics, the motion regulation of piston is analyzed and the mathematical model of compression processes is set up. Giving a calculating example, the vary trends of gas pressure and pistons' move in working process of booster have been gotten. The change of parameters at different working conditions is also calculated and compared. And the corresponding results can be referred in the design of air-driven boosters

  6. Picosecond ballistic imaging of diesel injection in high-temperature and high-pressure air

    Science.gov (United States)

    Duran, Sean P.; Porter, Jason M.; Parker, Terence E.

    2015-04-01

    The first successful demonstration of picosecond ballistic imaging using a 15-ps-pulse-duration laser in diesel sprays at temperature and pressure is reported. This technique uses an optical Kerr effect shutter constructed from a CS2 liquid cell and a 15-ps pulse at 532 nm. The optical shutter can be adjusted to produce effective imaging pulses between 7 and 16 ps. This technique is used to image the near-orifice region (first 3 mm) of diesel sprays from a high-pressure single-hole fuel injector. Ballistic imaging of dodecane and methyl oleate sprays injected into ambient air and diesel injection at preignition engine-like conditions are reported. Dodecane was injected into air heated to 600 °C and pressurized to 20 atm. The resulting images of the near-orifice region at these conditions reveal dramatic shedding of the liquid near the nozzle, an effect that has been predicted, but to our knowledge never before imaged. These shedding structures have an approximate spatial frequency of 10 mm-1 with lengths from 50 to 200 μm. Several parameters are explored including injection pressure, liquid fuel temperature, air temperature and pressure, and fuel type. Resulting trends are summarized with accompanying images.

  7. Space Charge Mitigation With Longitudinally Hollow Bunches

    CERN Multimedia

    Oeftiger, Adrian; Rumolo, Giovanni

    2016-01-01

    Hollow longitudinal phase space distributions have a flat profile and hence reduce the impact of transverse space charge. Dipolar parametric excitation with the phase loop feedback systems provides such hollow distributions under reproducible conditions. We present a procedure to create hollow bunches during the acceleration ramp of CERN’s PS Booster machine with minimal changes to the operational cycle. The improvements during the injection plateau of the downstream Proton Synchrotron are assessed in comparison to standard parabolic bunches.

  8. Transverse Impedance Model of the CERN-PSB

    OpenAIRE

    Zannini, Carlo; Iadarola, Giovanni; Jones, Bryan; Li, Kevin; Rijoff, Tatiana; Rumolo, Giovanni

    2015-01-01

    In the framework of the PS-Booster upgrade project an accurate impedance model is needed in order to determine the effect on the beam stability and assess the impact of the new devices before installation in the machine. This paper describes the PSB impedance model which includes resistive wall, indirect space charge, flanges, step transitions, ejection kicker including cables, injection kickers and cavities. Each impedance contribution has been computed for different energies in the PSB cycl...

  9. Broadband and short (10-ps) pulse generation on Nova

    International Nuclear Information System (INIS)

    Perry, M.D.; Browning, D.; Bibeau, C.; Patterson, F.G.; Wilcox, R.; Henesian, M.

    1990-01-01

    The ability to produce high power broadband pulses for purposes of focal spot beam smoothing has recently become an important issue in inertial confinement fusion (ICF). As the first step toward the generation and propagation of such pulses on Nova, the authors have performed a series of experiments with 10-ps pulses. Aside from the inherently broad bandwidth, these short pulses have important applications in ICF experiments and x-ray laser research. The author's experimental results are discussed. The short pulses were produced by diffraction grating pulse compression of chirped pulses formed from self-phase modulation in a single-mode 10-m fused silica fiber. Use of such a short fiber produces a nonlinearly chirped spectrum of 0.74 nm. The central nearly linearly chirped 0.26 nm is selected by polarization discrimination and compressed using 1800-line/mm diffraction gratings to a nearly Gaussian pulse of 10 ps FWHM with an energy contrast ratio of 20:1. This 1-nJ pulse is injected into a Nova amplifier chain with selected amplifiers unfired

  10. Booster fans : some considerations for their usage in underground coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Gillies, S.; Slaughter, C. [Missouri Univ. of Science and Technology, Rolla, MO (United States); Calizaya, F. [Utah Univ., Salt Lake City, UT (United States); Wu, H.W. [Gillies Wu Mining Technology Pty Ltd., Brisbane, QLD (Australia)

    2010-07-01

    This paper reported on a study that investigated the conditions under which booster fans can be used safely and efficiently in underground coal mines. Booster fans are installed in series with a main surface fan and are used to boost the air pressure of the ventilation air passing through it. Several coal mining countries use booster fans, but in the United States, they are only used in metal/non-metal mines due to concerns of uncontrolled recirculation. This study investigated installations of booster fans in non-US underground coal mines where safe and efficient atmospheric conditions are achieved. The purpose was to collect reliable information on airway resistances and flow requirements typical in large US coal mines. The study showed that safe booster fan installations are found in both high and low gas conditions, and sometimes where workings are located at great depths. The interlocking systems within the booster fan can control the underground fans and avoid recirculation when surface fans are unexpectedly turned off. Another purpose of the study was to determine when booster fans become a more viable solution in coal mines due to increases in air requirements at higher production rates. It was concluded that a new fan selection algorithm to produce recirculation-free ventilation designs will be developed to enable US coal mine operators to develop ventilation designs to extract coal seams from depths greater than 1000 m. 17 refs., 1 fig.

  11. Ram booster

    Science.gov (United States)

    Brand, Vance D. (Inventor); Morgan, Walter Ray (Inventor)

    2011-01-01

    The present invention is a space launch system and method to propel a payload bearing craft into earth orbit. The invention has two, or preferably, three stages. The upper stage has rocket engines capable of carrying a payload to orbit and provides the capability of releasably attaching to the lower, or preferably, middle stage. Similar to the lower stage, the middle stage is a reusable booster stage that employs all air breathing engines, is recoverable, and can be turned-around in a short time between missions.

  12. Release the beams! - Linac4 ready to hit the 50 MeV mark

    CERN Multimedia

    Katarina Anthony

    2015-01-01

    The Linac4 accelerator is now prepared to reach 50 MeV. This milestone energy - expected in the coming weeks - will allow the machine to act as a replacement for the ageing Linac2, four years before it takes over at the head of the accelerator chain in 2020.    Inside the Linac4 tunnel, the final DTL cavities will guide beams to 50 MeV.  (Image: Stephan Russenschuck.) The Linac4 accelerator will bring H- ion beams (hydrogen atoms with an extra electron) up to 160 MeV for injection into the PS Booster. As a key part of the LHC injector upgrade programme, Linac4 will allow the PS Booster to double its beam brightness, which will contribute to increasing the LHC’s luminosity. Linac4 will soon bring beams up to 50 MeV - the current energy delivered by the Linac2 accelerator. This milestone follows on from another recent accomplishment: the installation and commissioning of the final Drift Tube Linac (DTL) tank. Using an innovati...

  13. Proposed data acquisition system for the Fermilab Booster

    International Nuclear Information System (INIS)

    Bharadwaj, V.; Peggs, S.; Wu, G.; Saltmarsh, C.

    1991-01-01

    At present, studies involving the FNAL Booster (or in fact most accelerators) depend on knowing exactly what detector one has to look at and at what time. Because of this, most studies are done 'on-line' and involve looking for repetitive effects using a limited number of detectors. In this paper the authors propose to design a Booster Data Acquisition System (BDAQ) for the FNAL Booster. In essence this system consists of a large number of digitizers with circular memory buffers. After a machine cycle of interest, these buffers are frozen and then read out into a mass storage device. This paper discusses the hardware and software capabilities needed to make such a data acquisition system a powerful tool for doing accelerator physics studies and improving machine performance

  14. Space Charge Effects and Advanced Modelling for CERN Low Energy Machines

    CERN Document Server

    AUTHOR|(CDS)2088716; Rumolo, Giovanni

    The strong space charge regime of future operation of CERN’s circular particle accelerators is investigated and mitigation strategies are developed in the framework of the present thesis. The intensity upgrade of the injector chain of Large Hadron Collider (LHC) prepares the particle accelerators to meet the requirements of the High-Luminosity LHC project. Producing the specified characteristics of the future LHC beams imperatively relies on injecting brighter bunches into the Proton Synchrotron Booster (PSB), the downstream Proton Synchrotron (PS) and eventually the Super Proton Synchrotron (SPS). The increased brightness, i.e. bunch intensity per transverse emittance, entails stronger beam self-fields which can lead to harmful interaction with betatron resonances. Possible beam emittance growth and losses as a consequence thereof threaten to degrade the beam brightness. These space charge effects are partly mitigated by the upgrade of the PSB and PS injection energies. Nevertheless, the space charge tune ...

  15. Logic and control module for the Fermilab booster beam damper

    International Nuclear Information System (INIS)

    Sandberg, B.R.

    1977-01-01

    A logic and control module is included in the electronic system of the booster superdamper. This module produces a 9-bit digital word that controls the delay of beam bunch position information in the Fermilab booster synchrotron so that it arrives at the damping electrodes at the same time as the bunch of beam to be corrected. This delay word generator also has an output feature that only allows delay time decreases as the booster synchrotron frequency program increases monotonically. Such a feature guards against low-index incidental FM from affecting the delay computations

  16. Identifying strategies to improve the effectiveness of booster seat laws

    Science.gov (United States)

    2008-05-01

    The objective of this project was to identify strategies to improve the effectiveness of booster seat laws. The project explored the possible factors that relate to the use and nonuse of booster seats, and examined the attitudes of law enforcement of...

  17. The SPS was the second cross-border accelerator

    CERN Multimedia

    2004-01-01

    In the Golden Jubilee article in the issue 25/2004 (14 June) we should have written that the SPS was the first big cross-border accelerator. In fact, the SPS was not the first cross-border accelerator: that title goes to the PS Booster which became operational in 1972. The PS Booster passes beams to the PS and to the ISOLDE facility. We are sorry for the mistake and thank our vigilant readers.

  18. Academic Training: A walk through the LHC injector chain

    CERN Multimedia

    Françoise Benz

    2005-01-01

    2004-2005 ACADEMIC TRAINING PROGRAMME LECTURE SERIES 21, 22, 23 March from 11.00 to 12.00 hrs - Main Auditorium, bldg. 500 A walk through the LHC injector chain M. BENEDIKT, P. COLLIER, K. SCHINDL /CERN-AB Proton linac, PS Booster, PS, SPS and the two transfer channels from SPS to LHC are used for LHC proton injection. The lectures will review the features of these faithful machines and underline the modifications required for the LHC era. Moreover, an overview of the LHC lead ion injector scheme from the ion source through ion linac, LEIR, PS and SPS right to the LHC entry will be given. The particular behaviour of heavy ions in the LHC will be sketched and the repercussions on the injectors will be discussed. ENSEIGNEMENT ACADEMIQUE ACADEMIC TRAINING Françoise Benz 73127 academic.training@cern.ch

  19. Momentum Cogging at the Fermilab Booster

    International Nuclear Information System (INIS)

    Seiya, K.; Drennan, C.C.; Pellico, W.; Triplett, A.K.; Waller, A.M.

    2012-01-01

    The Fermilab Booster has an upgrade plan called the Proton Improvement Plan (PIP). The flux throughput goal is 2E17 protons/hour which, is almost double the present flux, 1.1E17 protons/hour. The beam loss in the machine is going to be an issue. The Booster accelerates beam from 400 MeV to 8 GeV and extracts to the Main Injector (MI). The current cogging process synchronizes the extraction kicker gap to the MI by changing radial position of the beam during the cycle. The gap creation occurs at about 700 MeV, which is about 6 ms into the cycle. The cycle-to-cycle variations of the Booster are larger at lower energy. However, changing the radial position at low energy for cogging is limited because of aperture. Momentum cogging is able to move the gap creation to an earlier time by using dipole correctors and radial position feedback, and is able to control the revolution frequency and radial position at the same time. The new cogging is expected to reduce beam loss and not be limited by aperture. The progress of the momentum cogging system development is going to be discussed in this paper.

  20. Synthesis and Characterization of the Rubidium Thiophosphate Rb 6 (PS 5 )(P 2 S 10 ) and the Rubidium Silver Thiophosphates Rb 2 AgPS 4 , RbAg 5 (PS 4 ) 2 and Rb 3 Ag 9 (PS 4 ) 4

    KAUST Repository

    Alahmary, Fatimah S.; Davaasuren, Bambar; Khanderi, Jayaprakash; Rothenberger, Alexander

    2016-01-01

    The metal thiophosphates Rb2AgPS4 (2), RbAg5(PS4)2 (3), and Rb3Ag9(PS4)4 (4) were synthesized by stoichiometric reactions, whereas Rb6(PS5)(P2S10) (1) was prepared with excess amount of sulfur. The compounds crystallize as follows: 1 monoclinic, P21

  1. High-level immunogenicity is achieved vaccine with adjuvanted pandemic H1N1(2009) and improved with booster dosing in a randomized trial of HIV-infected adults.

    Science.gov (United States)

    Cooper, Curtis; Klein, Marina; Walmsley, Sharon; Haase, David; MacKinnon-Cameron, Donna; Marty, Kimberley; Li, Yan; Smith, Bruce; Halperin, Scott; Law, Barb; Scheifele, David

    2012-01-01

    More severe influenza disease and poor vaccine immunogenicity in HIV-infected patients necessitate improved immunization strategies to maximize vaccine efficacy. A phase III, randomized trial was conducted at 4 Canadian sites. Two dosing strategies (standard dose vs standard dose plus booster on day 21) were assessed in HIV patients aged 20 to 59 years during the H1N1(2009) pandemic. A single antigen, inactivated split adjuvanted (AS03(A)) influenza vaccine (Arepanrix) was utilized. Serum hemagglutination inhibition (HAI) titres were assessed at days 21 and 42 and at month 6. 150 participants received at least one injection. Baseline parameters were similar between groups: 83% male, 85% on HAART, median CD4 = 519 cells/mm(3), 84% with HIV RNA < 50 copies/mL. At day 21, seroprotection (HAI ≥1:40) was achieved in 80% (95% CI, 70-89) of participants. Seroconversion occurred in 74% (63-85). Seroprotection and seroconversion were further improved in those randomized to booster dosing: day 42, 94% (85-98) versus 73% (60-83) (P < .01) and 86% (75-93) versus 66% (5-77) (P = .01). Seroprotec-tion was retained in 40% (28-54) of recipients at month 6 with trends toward greater retention of immunity in booster recipients. High-level immunogenicity was achieved with a single dose of this adjuvanted vaccine. Immunogenicity was further improved with booster dosing. Use of this adjuvanted vaccine and booster represent an important approach to increasing immunogenicity in this vaccine hypo-responsive population.

  2. OCT/PS-OCT imaging of brachial plexus neurovascular structures

    Science.gov (United States)

    Raphael, David T.; Zhang, Jun; Zhang, Yaoping; Chen, Zhongping; Miller, Carol; Zhou, Li

    2004-07-01

    Introduction: Optical coherence tomography (OCT) allows high-resolution imaging (less than 10 microns) of tissue structures. A pilot study with OCT and polarization-sensitive OCT (PS-OCT) was undertaken to image ex-vivo neurovascular structures (vessels, nerves) of the canine brachial plexus. Methods: OCT is an interferometry-based optical analog of B-mode ultrasound, which can image through non-transparent biological tissues. With approval of the USC Animal Care and Use Committee, segments of the supra- and infraclavicular brachial plexus were excised from euthanized adult dogs, and the ex-vivo specimens were placed in cold pH-buffered physiologic solution. An OCT beam, in micrometer translational steps, scanned the fixed-position bisected specimens in transverse and longitudinal views. Two-dimensional images were obtained from identified arteries and nerves, with specific sections of interest stained with hematoxylin-eosin for later imaging through a surgical microscope. Results: with the beam scan direction transverse to arteries, the resulting OCT images showed an identifiable arterial lumen and arterial wall tissue layers. By comparison, transverse beam OCT images of nerves revealed a multitude of smaller nerve bundles contained within larger circular-shaped fascicles. PS-OCT imaging was helpful in showing the characteristic birefringence exhibited by arrayed neural structures. Discussion: High-resolution OCT imaging may be useful in the optical identification of neurovascular structures during attempted regional nerve blockade. If incorporated into a needle-shaped catheter endoscope, such a technology could prevent intraneural and intravascular injections immediately prior to local anesthetic injection. The major limitation of OCT is that it can form a coherent image of tissue structures only to a depth of 1.5 - 2 mm.

  3. Space shuttle with common fuel tank for liquid rocket booster and main engines (supertanker space shuttle)

    Science.gov (United States)

    Thorpe, Douglas G.

    1991-01-01

    An operation and schedule enhancement is shown that replaces the four-body cluster (Space Shuttle Orbiter (SSO), external tank, and two solid rocket boosters) with a simpler two-body cluster (SSO and liquid rocket booster/external tank). At staging velocity, the booster unit (liquid-fueled booster engines and vehicle support structure) is jettisoned while the remaining SSO and supertank continues on to orbit. The simpler two-bodied cluster reduces the processing and stack time until SSO mate from 57 days (for the solid rocket booster) to 20 days (for the liquid rocket booster). The areas in which liquid booster systems are superior to solid rocket boosters are discussed. Alternative and future generation vehicles are reviewed to reveal greater performance and operations enhancements with more modifications to the current methods of propulsion design philosophy, e.g., combined cycle engines, and concentric propellant tanks.

  4. Beam Quality Preservation in the CERN PS-SPS Complex

    CERN Multimedia

    Arduini, Gianluigi

    2004-01-01

    The LHC will require beams of unprecedented transverse and longitudinal brightness. Their production imposes tight constraints on the emittance growth in each element of the LHC injector chain, namely the PS-SPS Accelerator Complex. The problems encountered at the different stages of the acceleration in the complex span a wide range of topics, such as injection matching, RF gymnastics, space charge, transverse and longitudinal single- and coupled-bunch instabilities, and electron cloud effects. The measurement techniques developed and applied to identify and study the various sources of emittance dilution to the high precision required for the LHC beams and the solutions found to control such phenomena are illustrated.

  5. Radiation protection studies for a high-power 160 MeV proton linac

    CERN Document Server

    Mauro, Egidio

    2009-01-01

    CERN is presently designing a new chain of accelerators to replace the present Proton Synchrotron (PS) complex: a 160 MeV room-temperature H− linac (Linac4) to replace the present 50 MeV proton linac injector, a 3.5 GeV Superconducting Proton Linac (SPL) to replace the 1.4 GeV PS Booster (PSB) and a 50 GeV synchrotron (named PS2) to replace the 26 GeV PS. Linac4 has been funded and the civil engineering work started in October 2008, whilst the SPL is in an advanced stage of design. Beyond injecting into the future 50 GeV PS, the ultimate goal of the SPL is to generate a 4 MW beam for the production of intense neutrino beams. The radiation protection design is driven by the latter requirement. This work summarizes the radiation protection studies conducted for Linac4. FLUKA Monte Carlo simulations, complemented by analytical estimates, were performed to evaluate the propagation of neutrons through the waveguide, ventilation and cable ducts placed along the accelerator, to estimate the radiological impact of ...

  6. submitter Radiation Protection Studies for CERN LINAC4/SPL Accelerator Complex

    CERN Document Server

    Mauro, Egidio; Silari, Marco

    2009-01-01

    CERN is presently designing a new chain of accelerators to replace the present Proton Synchrotron (PS) complex: a 160 MeV room-temperature H$^-$ linac (Linac4) to replace the present 50 MeV proton linac injector, a 3.5 GeV Superconducting Proton Linac (SPL) to replace the 1.4 GeV PS booster (PSB) and a 50 GeV synchrotron (named PS2) to replace the 26 GeV PS. Linac4 has been funded and the civil engineering work started in October 2008, whilst the SPL is in an advanced stage of design. Beyond injecting into the future 50 GeV PS, the ultimate goal of the SPL is to generate a 4 MW beam for the production of intense neutrino beams. The radiation protection design is driven by the latter requirement. This thesis summarizes the radiation protection studies conducted for Linac4. FLUKA Monte Carlo simulations, complemented by analytical estimates, were performed 1) to evaluate the propagation of neutrons through the waveguide, ventilation and cable ducts placed along the accelerator, 2) to estimate the radiological i...

  7. Direct Observation of Ultrafast Hole Injection from Lead Halide Perovskite by Differential Transient Transmission Spectroscopy.

    Science.gov (United States)

    Ishioka, Kunie; Barker, Bobby G; Yanagida, Masatoshi; Shirai, Yasuhiro; Miyano, Kenjiro

    2017-08-17

    Efficient charge separation at the interfaces of the perovskite with the carrier transport layers is crucial for perovskite solar cells to achieve high power conversion efficiency. We present a systematic experimental study on the hole injection dynamics from MAPbI 3 perovskite to three typical hole transport materials (HTMs). We extract the carrier dynamics directly related to the hole injection by employing a pump light with short absorption depth and comparing the transient transmission signals excited on the two sides of the sample. The differential transmission signals reveal the hole injections to PTAA and PEDOT:PSS to be complete within 1 and 2 ps, respectively, and that to NiO x to exhibit an additional slow process on a 40 ps time scale. The obtained injection dynamics are discussed in comparison with the device performance of the solar cells containing the same MAPbI 3 /HTM interfaces.

  8. Linac boosters for electrostatic machines

    International Nuclear Information System (INIS)

    Ben-Zvi, I.; Brookhaven National Lab., Upton, NY

    1990-01-01

    A survey of linacs which are used as boosters to electrostatic accelerators is presented. Machines both operating and under construction, copper and superconducting, are reviewed. The review includes data on the accelerating structures, performance, rf and control, beam optics, budget, vacuum and cryogenics. (orig.)

  9. A real time status monitor for transistor bank driver power limit resistor in boost injection kicker power supply

    Energy Technology Data Exchange (ETDEWEB)

    Mi, J.; Tan, Y.; Zhang, W.

    2011-03-28

    For years suffering of Booster Injection Kicker transistor bank driver regulator troubleshooting, a new real time monitor system has been developed. A simple and floating circuit has been designed and tested. This circuit monitor system can monitor the driver regulator power limit resistor status in real time and warn machine operator if the power limit resistor changes values. This paper will mainly introduce the power supply and the new designed monitoring system. This real time resistor monitor circuit shows a useful method to monitor some critical parts in the booster pulse power supply. After two years accelerator operation, it shows that this monitor works well. Previously, we spent a lot of time in booster machine trouble shooting. We will reinstall all 4 PCB into Euro Card Standard Chassis when the power supply system will be updated.

  10. JAERI tandem-accelerator and tandem-booster

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Tadashi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-03-01

    In 1982, aiming at the new development of atomic energy research, the tandem accelerator of Japan Atomic Energy Research Institute (JAERI) was installed. In fiscal year 1993, the superconducting boosters which can increase the ion energy by up to 4 times were added, and the research in the region below 1000 MeV became possible. Those are electrostatic type accelerators which are easy to be used especially in basic research field, and are useful for future research. The tandem accelerator has been operated while maintaining the first class performance as the accelerator for various kinds of heavy ion beam. It has the special shape among electrostatic type accelerators, and is excellent in the easiness of control and stability. The main particulars of the tandem accelerator are shown. As for the ion sources of the tandem accelerator, three cesium sputter type ion sources are installed on two high voltage stands. The kinds of the ions which can be accelerated are mainly negative ions. As the improvement, electron cyclotron resonance (ECR) ion sources are expected to be adopted. As for the tandem boosters, the 1/4 wavelength type resonance hollow cylinder was adopted. The constitution of the tandem boosters is explained. The way of utilizing the tandem accelerator system and the aim for hereafter are reported. (K.I.)

  11. Symmetry of dipositronium Ps2

    International Nuclear Information System (INIS)

    Schrader, D.M.

    2004-01-01

    We work out the complete symmetry and spin problem for diatomic positronium Ps 2 for the ground and singly excited states of zero orbital angular momentum. The general form of the wave function for each state is given, with due regard to charge conjugation parity. Annihilation rates are discussed, and correlations to dissociation products are deduced. We indicate how the approach is extensible to larger aggregates: i.e., PsPs n , n>2

  12. 47 CFR 74.1290 - FM translator and booster station information available on the Internet.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false FM translator and booster station information... DISTRIBUTIONAL SERVICES FM Broadcast Translator Stations and FM Broadcast Booster Stations § 74.1290 FM translator and booster station information available on the Internet. The Media Bureau's Audio Division...

  13. Model based controls and the AGS booster controls system architecture

    International Nuclear Information System (INIS)

    Casella, R.A.

    1987-01-01

    For the past three years the Accelerator Controls Section has been responsible for the development of the Heavy Ion Transfer Line (HITL) used to inject heavy ions created at the Tandem Van de Graaff into the Alternating Gradient Synchrotron (AGS). This was recognized as an opportunity to test new ideas for control of a beam line, which if successful, could be implemented in an upgrade of the existing control system for the AGS. The in place control system for the AGS consisted of DEC PDP10 computer as the primary computer interface to the accelerator via three control room consoles, and keeper of the device database. For the HITL project it was decided to make the control system a true distributed network putting more computing power down at the device level via intelligent subsystems. A network of Apollo workstations was added at the host level. Apollos run a distributed operating system and are connected to each other by the Domain Token Ring Network. The Apollos were seen as the new primary computers for consoles with each console containing at least one Apollo. These hosts and all other subsystems are connected to each other via an in house developed LAN (RELWAY). The design of the control system developed for HITL was mostly successful. The proposed AGS Booster is designed to be a synchrotron injector for the AGS. With the forthcoming development of the Booster for the AGS an opportunity has again developed to implement new ideas for accelerator control. One weakness of the HITL control system is the limited cpu power and poor debugging facilities of the stations

  14. 78 FR 29062 - Signal Booster Rules

    Science.gov (United States)

    2013-05-17

    ... number of FCC rules concerning signal boosters for consumer and industrial use. This document corrects a... chapter; the Maritime Services (ship earth station devices only) pursuant to part 80 of this chapter; and...

  15. The AGS Booster Beam Position Monitor system

    International Nuclear Information System (INIS)

    Ciardullo, D.J.; Abola, A.; Beadle, E.R.; Smith, G.A.; Thomas, R.; Van Zwienen, W.; Warkentien, R.; Witkover, R.L.

    1991-01-01

    To accelerate both protons and heavy ions, the AGS Booster requires a broadband (multi-octave) beam position monitoring system with a dynamic range spanning several orders of magnitude (2 x 10 10 to 1.5 x 10 13 particles per pulse). System requirements include the ability to acquire single turn trajectory and average orbit information with ± 0.1 mm resolution. The design goal of ± 0.5 mm corrected accuracy requires that the detectors have repeatable linear performance after periodic bakeout at 300 degree C. The system design and capabilities of the Booster Beam Position Monitor will be described, and initial results presented. 7 refs., 5 figs

  16. Advanced Booster Composite Case/Polybenzimidazole Nitrile Butadiene Rubber Insulation Development

    Science.gov (United States)

    Gentz, Steve; Taylor, Robert; Nettles, Mindy

    2015-01-01

    The NASA Engineering and Safety Center (NESC) was requested to examine processing sensitivities (e.g., cure temperature control/variance, debonds, density variations) of polybenzimidazole nitrile butadiene rubber (PBI-NBR) insulation, case fiber, and resin systems and to evaluate nondestructive evaluation (NDE) and damage tolerance methods/models required to support human-rated composite motor cases. The proposed use of composite motor cases in Blocks IA and II was expected to increase performance capability through optimizing operating pressure and increasing propellant mass fraction. This assessment was to support the evaluation of risk reduction for large booster component development/fabrication, NDE of low mass-to-strength ratio material structures, and solid booster propellant formulation as requested in the Space Launch System NASA Research Announcement for Advanced Booster Engineering Demonstration and/or Risk Reduction. Composite case materials and high-energy propellants represent an enabling capability in the Agency's ability to provide affordable, high-performing advanced booster concepts. The NESC team was requested to provide an assessment of co- and multiple-cure processing of composite case and PBI-NBR insulation materials and evaluation of high-energy propellant formulations.

  17. MEASUREMENTS AND MODELING OF EDDY CURRENT EFFECTS IN BNL'S AGS BOOSTER

    International Nuclear Information System (INIS)

    BROWN, K.A.; AHRENS, L.; GARDNER, C.; GLENN, J.W.; HARVEY, M.; MENG, W.; ZENO, K.

    2006-01-01

    Recent beam experiments at BNL's AGS Booster have enabled us to study in more detail the effects of eddy currents on the lattice structure and our control over the betatron tune. The Booster is capable of operating at ramp rates as high as 9 T/sec. At these ramp rates eddy currents in the vacuum chambers significantly alter the fields and gradients seen by the beam as it is accelerated. The Booster was designed with these effects in mind and to help control the field uniformity and linearity in the Booster Dipoles special vacuum chambers were designed with current windings to negate the affect of the induced eddy currents. In this report results from betatron tune measurements and eddy current simulations will be presented. We will then present results from modeling the accelerator using the results of the magnetic field simulations and compare these to the measurements

  18. Tdap Booster Requirements for Secondary Schools

    Science.gov (United States)

    ... Experts State Information Tdap booster requirements for secondary schools State Td or Tdap Mandate for Sec School ... Checklists Standing Orders Storage & Handling Talking with Parents Temperature Logs Top Handouts Translations Vaccine Index >> view all ...

  19. Thermographic analysis of photodynamic therapy with intense pulsed light and needle-free injection photosensitizer delivery: an animal study

    Science.gov (United States)

    Requena, Michelle B.; Stringasci, Mirian D.; Pratavieira, Sebastião.; Vollet-Filho, José Dirceu; de Nardi, Andrigo B.; Escobar, Andre; da Rocha, Rozana W.; Bagnato, Vanderlei S.; de Menezes, Priscila F. C.

    2018-02-01

    The photodynamic therapy (PDT) is a therapeutic modality that depends mostly on photosensitizer (PS), light and molecular oxygen species. However, there are still technical limitations in clinical PDT that are under constant development, particularly concerning PS and light delivery. Intense Pulsed Light (IPL) sources are systems able to generate pulses of high energy with polychromatic light. IPL is a technique mainly used in the cosmetic area to perform various skin treatments for therapeutic and aesthetic applications. The goals of this study were to determine temperature variance during the application of IPL in porcine skin model, and the PDT effects using this light source with PS delivery by a commercial high pressure, needle-free injection system. The PSs tested were Indocyanine Green (ICG) and Photodithazine (PDZ), and the results showed an increase bellow 10 °C in the skin surface using a thermographic camera to measure. In conclusion, our preliminary study demonstrated that IPL associated with needle-free injection PS delivery could be a promising alternative to PDT.

  20. Psychometric properties of the OARSI/OMERACT osteoarthritis pain and functional impairment scales: ICOAP, KOOS-PS and HOOS-PS.

    Science.gov (United States)

    Ruyssen-Witrand, A; Fernandez-Lopez, C J; Gossec, L; Anract, P; Courpied, J P; Dougados, M

    2011-01-01

    To evaluate the psychometric properties of the OARSI-OMERACT questionnaires in comparison to the existing validated scales. Consecutive hip or knee osteoarthritis patients consulting in an orthopedic department were enrolled in the study. Data collected were pain using the Intermittent and Constant Osteoarthritis Pain (ICOAP), a Numeric Rating Scale (NRS), the Western Ontario McMaster Universities' Osteoarthritis Index (WOMAC) pain subscale, the Lequesne pain subscale; functional impairment using the Knee disability and Osteoarthritis Outcome Score-Physical Function Shortform (KOOS-PS), the Hip disability and Osteoarthritis Outcome Score-Physical Function Shortform (HOOS-PS), a NRS, the WOMAC function sub-scale, the Lequesne function subscale. Validity was assessed by calculating the Spearman's correlation coefficient between all the scales. Reliability was assessed in out-patients with stable disease comparing the data collected within 2 weeks using the intra-class correlation coefficient (ICC). Responsiveness was assessed on the data from hospitalised patients prior to and 12 weeks after a total joint replacement (TJR) using the standardised response mean. Three hundred patients (mean age=68 years, females=62%, hip OA=57%) were included. There was a moderate to good correlation between ICOAP, KOOS-PS, HOOS-PS and the WOMAC, NRS and Lequesne scales. Reliability of the ICOAP hip OA HOOS-PS and KOOS-PS was good (ICC range 0.80-0.81) whereas it was moderate for knee ICOAP (ICC=0.65). Responsiveness of the ICOAP, KOOS-PS and HOOS-PS 12 weeks after TJR was comparable to responsiveness of other scales (SRM range: 0.54-1.82). The psychometric properties of the ICOAP, KOOS-PS and HOOS-PS were comparable to those of the WOMAC, Lequesne and NRS.

  1. Emittance measurement and modeling for the Fermilab Booster

    Directory of Open Access Journals (Sweden)

    Xiaobiao Huang

    2006-01-01

    Full Text Available Turn-by-turn beam profile data measured at the Fermilab Booster are studied. Lattice models with experimental accelerator ramping parameters are used to obtain the lattice functions for data analysis. We studied the horizontal and vertical emittance growth behavior in different stages of a booster ramping cycle and its relation to the beam intensity. The transverse and longitudinal components in the horizontal beam width are separated by a fitting model which makes use of the different scaling rules of the beam momentum. We analyze the post-transition horizontal beam size oscillation based on a model where the longitudinal phase-space mismatch has resulted from rf voltage mismatch during the transition-energy crossing. We carried out systematic multiparticle simulation to show that the source of the vertical emittance growth is a combination of the random errors in skew-quadrupole and dipole fields, and the systematic Montague resonance. The effect of random quadrupole field is small for the Fermilab Booster because the betatron envelope tunes are reasonably far away from the half-integer stop band.

  2. Expectation values of the e+PsH system

    International Nuclear Information System (INIS)

    Zhang, J.-Y.; Mitroy, J.

    2007-01-01

    Close to converged energies and expectation values for e + PsH are computed using a ground-state wave function consisting of 1500 explicitly correlated Gaussians. The best estimate of the e + PsH ∞ energy was -0.810 254 hartrees, which has a binding energy of 0.021 057 hartrees against dissociation into e + +PsH. The 2γ annihilation rate was 2.7508x10 9 s -1 . Binding energies and annihilation rates are also given for the different finite-mass variants of e + PsH. Comparisons between expectation values for e + PsH and PsH provide compelling evidence that the e + PsH ground state can be regarded as consisting of a weakly bound positron orbiting the PsH ground state

  3. Design and Development of RF Structures for Linac4

    CERN Document Server

    Vretenar, M; Gerigk, F; Pasini, M; Wegner, R

    2006-01-01

    Linac4 is a new 160 MeV H− linac proposed at CERN to replace the 50 MeV Linac2 as injector to the PS Booster, with the goal of doubling its brightness and intensity. The present design foresees after RFQ and chopping line a sequence of three accelerating structures: a Drift Tube Linac (DTL) from 3 to 40 MeV, a Cell-Coupled DTL (CCDTL) to 90 MeV and a Side Coupled Linac (SCL) up to the final energy. The DTL and CCDTL operate at 352 MHz, while in the SCL the frequency is doubled to 704 MHz. Although the injection in the PS Booster requires only a low duty cycle, the accelerating structures are designed to operate at the high duty cycle required by a possible future extension to a high-power linac driver for a neutrino facility. This paper presents the different accelerating structures, underlining the progress in the design of critical resonator elements, like post-couplers in the DTL, coupling slots in the CCDTL and bridge couplers for the SCL. Prototyping progress for the different structures is reported...

  4. 76 FR 11680 - Digital Low Power Television, Television Translator, and Television Booster Stations and Digital...

    Science.gov (United States)

    2011-03-03

    ...] Digital Low Power Television, Television Translator, and Television Booster Stations and Digital Class A... Commission's Rules to Establish Rules for Digital Low Power, Television Translator, and Television Booster... Digital Low Power Television Translator, Television Booster Stations, and to Amend Rules for Digital Class...

  5. NASA's Space Launch System: Developing the World's Most Powerful Solid Booster

    Science.gov (United States)

    Priskos, Alex

    2016-01-01

    NASA's Journey to Mars has begun. Indicative of that challenge, this will be a multi-decadal effort requiring the development of technology, operational capability, and experience. The first steps are under way with more than 15 years of continuous human operations aboard the International Space Station (ISS) and development of commercial cargo and crew transportation capabilities. NASA is making progress on the transportation required for deep space exploration - the Orion crew spacecraft and the Space Launch System (SLS) heavy-lift rocket that will launch Orion and large components such as in-space stages, habitat modules, landers, and other hardware necessary for deep-space operations. SLS is a key enabling capability and is designed to evolve with mission requirements. The initial configuration of SLS - Block 1 - will be capable of launching more than 70 metric tons (t) of payload into low Earth orbit, greater mass than any other launch vehicle in existence. By enhancing the propulsion elements and larger payload fairings, future SLS variants will launch 130 t into space, an unprecedented capability that simplifies hardware design and in-space operations, reduces travel times, and enhances the odds of mission success. SLS will be powered by four liquid fuel RS-25 engines and two solid propellant five-segment boosters, both based on space shuttle technologies. This paper will focus on development of the booster, which will provide more than 75 percent of total vehicle thrust at liftoff. Each booster is more than 17 stories tall, 3.6 meters (m) in diameter and weighs 725,000 kilograms (kg). While the SLS booster appears similar to the shuttle booster, it incorporates several changes. The additional propellant segment provides additional booster performance. Parachutes and other hardware associated with recovery operations have been deleted and the booster designated as expendable for affordability reasons. The new motor incorporates new avionics, new propellant

  6. The heavy ion injection scheme for RHIC [Relativistic Heavy Ion Collider

    International Nuclear Information System (INIS)

    Rhoades-Brown, M.J.

    1989-01-01

    The Relativistic Heavy Ion Collider (RHIC) at Brookhaven has a multi-component injection system. The Collider requires very heavy ions such as 79 197 Au to be injected fully stripped of atomic electrons, at a kinetic energy of approximately 10 GeV/nucleon. However, the heavy ions are produced initially at a negative ion source and accelerated first in a 15 MV Tandem. These partially stripped ions have a kinetic energy of approximately 1 MeV/nucleon on leaving the Tandem. In order to achieve the injection requirements for RHIC, the partially stripped ions are accelerated in the Booster (currently under construction) and pass through a stripping foil on their way to the Alternating Gradient Synchrotron (AGS), where they are further accelerated before injection into RHIC. Recent theoretical calculations have shown quite convincingly that very heavy ions with 2 electrons in the filled K-shell may be accelerated with negligible loss in the AGS. 13 refs., 3 figs., 3 tabs

  7. Sequence control of phase separation and dewetting in PS/PVME blend thin films by changing molecular weight of PS.

    Science.gov (United States)

    Xia, Tian; Qin, Yaping; Huang, Yajiang; Huang, Ting; Xu, Jianhui; Li, Youbing

    2016-11-28

    The morphology evolution mechanism of polystyrene (PS)/poly (vinyl methyl ether) (PVME) blend thin films with different PS molecular weights (M w ) was studied. It was found that the morphology evolution was closely related to the molecular weight asymmetry between PS and PVME. In the film where M w (PS) ≈ M w (PVME), dewetting happened at the interface between the bottom layer and substrate after SD phase separation. While in the film where M w (PS) > M w (PVME), dewetting happened at the interface between the middle PS/PVME blend layer and bottom PVME layer near the substrate prior to phase separation. The different sequences of phase separation and dewetting and different interface for dewetting occurrence were studied by regarding the competitive effects of viscoelasticity contrast between polymer components and preferential wetting between PVME and the substrate. The viscoelastic nature of the PS component played a crucial role in the sequence of phase separation and dewetting.

  8. Thermoeconomic model of a commercial transcritical booster refrigeration system

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Elmegaard, Brian

    2011-01-01

    For cooling applications in supermarkets, booster refrigeration systems operating in both transcritical and subcritical conditions are increasingly used. A thermodynamic model of a transcritical booster refrigeration plant is tailored to match the new generation of commercial refrigeration plants...... of exergy for cooling. Second law analysis is needed to illustrate the characteristics of the plant at different load rates, according to the alternating load profile and corresponding to outdoor conditions. With the detailed model, different uses of the analysis are possible, including thermoeconomic...

  9. Groundwater Hydrology and Chemistry in and near an Emulsified Vegetable-Oil Injection Zone, Solid Waste Management Unit 17, Naval Weapons Station Charleston, North Charleston, South Carolina, 2004-2009

    Science.gov (United States)

    Vroblesky, Don A.; Petkewich, Matthew D.; Lowery, Mark A.; Conlon, Kevin J.; Casey, Clifton C.

    2010-01-01

    The U.S. Geological Survey and the Naval Facilities Engineering Command Southeast investigated the hydrology and groundwater chemistry in the vicinity of an emulsified vegetable-oil injection zone at Solid Waste Management Unit (SWMU) 17, Naval Weapons Station Charleston, North Charleston, South Carolina. In May 2004, Solutions-IES initiated a Phase-I pilot-scale treatability study at SWMU17 involving the injection of an edible oil emulsion into the aquifer near wells 17PS-01, 17PS-02, and 17PS-03 to treat chlorinated solvents. The Phase-I injection of emulsified vegetable oil resulted in dechlorination of trichloroethene (TCE) to cis-1,2-dichloroethene (cDCE), but the dechlorination activity appeared to stall at cDCE, with little further dechlorination of cDCE to vinyl chloride (VC) or to ethene. The purpose of the present investigation was to examine the groundwater hydrology and chemistry in and near the injection zone to gain a better understanding of the apparent remediation stall. It is unlikely that the remediation stall was due to the lack of an appropriate microbial community because groundwater samples showed the presence of Dehalococcoides species (sp.) and suitable enyzmes. The probable causes of the stall were heterogeneous distribution of the injectate and development of low-pH conditions in the injection area. Because groundwater pH values in the injection area were below the range considered optimum for dechlorination activity, a series of tests was done to examine the effect on dechlorination of increasing the pH within well 17PS-02. During and following the in-well pH-adjustment tests, VC concentrations gradually increased in some wells in the injection zone that were not part of the in-well pH-adjustment tests. These data possibly reflect a gradual microbial acclimation to the low-pH conditions produced by the injection. In contrast, a distinct increase in VC concentration was observed in well 17PS-02 following the in-well pH increase. Adjustment

  10. Dynamics of Singlet Fission and Electron Injection in Self-Assembled Acene Monolayers on Titanium Dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Justin C [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Pace, Natalie A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Arias, Dylan H [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Christensen, Steven T [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Granger, Devin B. [University of Kentucky; Anthony, John E. [University of Kentucky

    2018-02-26

    We employ a combination of linear spectroscopy, electrochemistry, and transient absorption spectroscopy to characterize the interplay between electron transfer and singlet fission dynamics in polyacene-based dyes attached to nanostructured TiO2. For triisopropyl silylethynyl (TIPS)-pentacene, we find that the singlet fission time constant increases to 6.5 ps on a nanostructured TiO2 surface relative to a thin film time constant of 150 fs, and that triplets do not dissociate after they are formed. In contrast, TIPS-tetracene singlets quickly dissociate in 2 ps at the molecule/TiO2 interface, and this dissociation outcompetes the relatively slow singlet fission process. The addition of an alumina layer slows down electron injection, allowing the formation of triplets from singlet fission in 40 ps. However, the triplets do not inject electrons, which is likely due to a lack of sufficient driving force for triplet dissociation. These results point to the critical balance required between efficient singlet fission and appropriate energetics for interfacial charge transfer.

  11. Numerically controlled oscillator for the Fermilab Booster

    International Nuclear Information System (INIS)

    Crisp, J.L.; Ducar, R.J.

    1989-01-01

    In order to improve the stability of the Fermilab Booster low level rf system, a numerically controlled oscillator system is being constructed. Although the system has not been implemented to date, the design is outlined in this paper. The heart of the new system consists of a numerically synthesized frequency generator manufactured by the Sciteq Company. The 3 GHz/sec rate and 30 to 53 MHz range of the Booster frequency program required the design of a CAMAC based, fast-cycling (1 MHz), 65K x 32 bit, digital function generator. A 1 MHz digital adder and 12 bit analog to digital converter will be used to correct small program errors by phase locking the oscillator to the beam. 6 refs., 1 fig

  12. Linac4 RFQ assembly is carried out before installation in Building 152

    CERN Multimedia

    Anna Pantelia

    2012-01-01

    This series of pictures documents the assembly phase of the Linac4 RFQ (Radio Frequency Quadrupole), performed at the end of July 2012. The Linac4 RFQ is made of 3 modules, 1 meter each, assembled together to accelerate the H- or proton beam from the ion source extraction at 45 kV to the energy of 3 MeV. The RFQ is the first of the Linac4 accelerating structures, which will increase to 160 MeV the beam injection energy into the PS Booster as from the end of LS2.

  13. Electron Spin Resonance studies on PS, PP and PS/PP blends under gamma irradiation

    International Nuclear Information System (INIS)

    Reyes, J.; Claro, M.; Albano, C.; Venezuela Central University, Caracas; Moronta, D.

    2002-01-01

    Complete text of publication follows. Electron Spin Resonance (ESR) studies on Polystyrene (PS), Polypropylene (PP) and their mixtures at compositions of 80/20 with and without a compatibilizer (SBS in block), 7.5 wt.%, irradiated with gamma rays from a Cobalt-60 source with a dose rate of 4.8 KGy/h at integral doses of radiation of 10, 25, 50, 60, 70, 400, 800 and 1300 KGy in the presence of air and at room temperature (RT) are reported. The dependence of resonance line width, Hpp; resonance line shapes K, and radical concentration, S, with the integral dose of irradiation is investigated. The nature of the free radicals after ten days of air storage is discussed. The free radical concentration, the double integral of the resonance line, S, has been estimated at room temperature, RT, for a group of single lines, characterized by the same giromagnetic, g, value by direct numerical double integration. In the samples studied no spectrum of 0 kGy of integral dose was observed. The concentration of radicals, S, observed when the integral radiation doses was increased, presents a maximum value in the PP samples at high doses (70-1300 kGy) and minimum values in the PS samples with the same doses. This shows that the PP degrades at a faster rate than the PS, owing to the presence of the bencenic ring in the latter. In the PS/PP mixtures studied with and without compatibilizer, the values of the radical concentration is found between the observed values in the homopolymers, being closer to the PS, which might imply that the presence of PS decays the degradation process of the PP in the mixture

  14. Cs0.49NbPS6

    Directory of Open Access Journals (Sweden)

    Hoseop Yun

    2011-01-01

    Full Text Available The quaternary thiophosphate, Cs0.49NbPS6, caesium hexathioniobiophosphate(V, has been synthesized by the reactive halide flux method. The title compound is isotypic with Rb0.46TaPS6 and is made up of a bicapped trigonal–biprismatic [Nb2S12] unit and a tetrahedral [PS4] group. The [Nb2S12] units linked by the [PS4] tetrahedra form infinite chains, yielding a three-dimensional network with rather large van der Waals gaps along the c axis in which the disordered Cs+ ions reside. The electrons released by the Cs atoms are transferred to the pairwise niobium metal site and there are substantial intermetallic Nb—Nb bonding interactions. This leads to a significant decrease of the intermetallic distance in the title compound compared to that in TaPS6. The classical charge balance of the title compound may be represented as [Cs+]0.49[Nb4.51+][P5+][S2−]4[S22−].

  15. The operational status of the Booster injector for the AGS accelerator complex at BNL

    International Nuclear Information System (INIS)

    Ahrens, L.; Bleser, E.; Brennan, J.M.; Gardner, C.; Gill, E.; Glenn, J.W.; Reece, K.; Roser, T.; van Asselt, W.; Weng, W.T.

    1992-01-01

    The Booster synchrotron at Brookhaven National Laboratory has been incorporated into the accelerator chain at the Alternating Gradient Synchrotron (AGS) complex. After a successful first commissioning effort in the spring of 1991, the Booster has been part of this year's silicon, gold and proton physics runs. After a brief review of the Booster design goals, and of the early commissioning, this paper will summarize this year's activities

  16. GRYPHON: Air launched space booster

    Science.gov (United States)

    1993-06-01

    The project chosen for the winter semester Aero 483 class was the design of a next generation Air Launched Space Booster. Based on Orbital Sciences Corporation's Pegasus concept, the goal of Aero 483 was to design a 500,000 pound air launched space booster capable of delivering 17,000 pounds of payload to Low Earth Orbit and 8,000 pounds of payload to Geosynchronous Earth Orbit. The resulting launch vehicle was named the Gryphon. The class of forty senior aerospace engineering students was broken down into eight interdependent groups. Each group was assigned a subsystem or responsibility which then became their field of specialization. Spacecraft Integration was responsible for ensuring compatibility between subsystems. This group kept up to date on subsystem redesigns and informed those parties affected by the changes, monitored the vehicle's overall weight and dimensions, and calculated the mass properties of the booster. This group also performed the cost/profitability analysis of the Gryphon and obtained cost data for competing launch systems. The Mission Analysis Group was assigned the task of determining proper orbits, calculating the vehicle's flight trajectory for those orbits, and determining the aerodynamic characteristics of the vehicle. The Propulsion Group chose the engines that were best suited to the mission. This group also set the staging configurations for those engines and designed the tanks and fuel feed system. The commercial satellite market, dimensions and weights of typical satellites, and method of deploying satellites was determined by the Payloads Group. In addition, Payloads identified possible resupply packages for Space Station Freedom and identified those packages that were compatible with the Gryphon. The guidance, navigation, and control subsystems were designed by the Mission Control Group. This group identified required tracking hardware, communications hardware telemetry systems, and ground sites for the location of the Gryphon

  17. Dynamic aperture ampersand extraction studies for the SSC High-Energy Booster

    International Nuclear Information System (INIS)

    Chao, A.W.; Dutt, S.K.; Johnson, D.E.; Sen, T.; Yan, Y.

    1990-09-01

    The final booster in the injector chain for the Superconducting Super Collider is a machine approximately twice the size of the Tevatron. Its design includes approximately 450, 15+ m superconducting dipoles. The original designs specified dipoles with a 7 cm coil-winding diameter and an inner horizontal beam-pipe aperture of 55 mm. This dipole design was chosen in order to provide an adequately large good-field aperture for both the beam injection process and for the slow-extraction of high-energy test beams. With the recent decision to increase the Collider dipole coil-winding diameter to 5 cm, the question of the needed HEB aperture was raised. An argument for dipole commonality between the HEB and Collider was developed, and a preliminary examination of a 5 cm HEB dipole was undertaken. This paper reports the results of a detailed study of the injection dynamic aperture for magnet errors corresponding to both a 5 cm and 7 cm dipole. Also studied and reported are preliminary results of the resonant-extraction process for the two magnet designs in question. These studies are in the form of multiparticle computer simulations. The results of the studies indicate that the 7 cm dipole design is consistent with the desired performance requirements for the HEB, while the 5 cm dipole design is marginal. We have not studied intermediate aperture values. 8 refs., 11 figs

  18. Fiber optics in the BNL Booster radiation environment

    International Nuclear Information System (INIS)

    Beadle, E.R.

    1991-01-01

    The Booster instrumentation uses analog and digital fiber optic links, designed to withstand at least 50 krads without performance degradation. The links use inexpensive and commercially available components that operate at a center wavelength of 820 nm. The analog link operates to 30 MHz over a 200 m fiber and can provide insertion gain. The digital link provides 60 ns timing pulses without the dispersive effects of coaxial cables. The optical fiber is a step-index hard clad silica type with a 200 micron core. This paper presents the component selection criteria, link design, installation, testing and performance for the optical links in the Booster instrumentation systems

  19. SPS and PS Experiments Committee

    CERN Multimedia

    CERN. Geneva

    2004-01-01

    OPEN SESSION: 09:00 Status report of NA58 / COMPASS: A. Magnon 09:40 Status report of PS212 / DIRAC: L. Tausher 10:10 PS212 / DIRAC Addendum: L. Nemenov CLOSED SESSION on Tuesday, 27 April 2004 after the open session, Main Building, 6th floor conference room

  20. Psühhodramaatikud annavad Pärnus eksami

    Index Scriptorium Estoniae

    2008-01-01

    29. maist kuni 1. juunini kestab Pärnus psühhodraama konverents "Geeniuste kohtumine", kus rahvusvahelise koolituse läbinud annavad eksami. Ruuda Palmquist on psühhodraama kui teadusharu rajajaid Eestis. Pärnus on kohal Rootsi Moreno Instituudi juhataja, psühhodraama lavastaja Marc Treadwell

  1. Misuse of booster cushions among children and adults in Shanghai-an observational and attitude study during buckling up.

    Science.gov (United States)

    Bohman, Katarina; Jorlöv, Sofia; Zhou, Shengqi; Zhao, Cloud; Sui, Bo; Ding, Chengkai

    2016-10-02

    Traffic crashes are one of the leading causes of fatalities among Chinese children. Booster cushion usage in China is low, and there are no studies showing how a population with limited experience handles booster cushions during buckling up. The purpose of this study was to evaluate the handling of and explore the attitudes toward booster cushions among children, parents, and grandparents in Shanghai. An observational study including a convenience sample of 254 children aged 4-12 years was conducted in 2 passenger cars at a shopping center in Shanghai. Parents, grandparents, or the children themselves buckled up the child on 2 types of booster cushions, a 2-stage integrated booster cushion (IBC) and an aftermarket booster cushion (BC). The test participants were observed during buckling up, first without and then with instructions. The test leaders conducted structured interviews. Ninety-eight percent of the uninstructed participants failed to buckle up without identified misuse on the aftermarket booster cushion and 31% of those uninstructed on the integrated booster cushion. The majority of misuse was severe, including placing the belt behind the arm and the lap belt routing above the guiding loops. Instruction reduced misuse to 58% (BC) and 12% (IBC), respectively, and, in particular, severe misuse. Some misuse was related to limited knowledge of how to buckle up on the booster cushion, and some misuse was intentional in order to reduce discomfort. The participants, both children and adults, reported that they preferred the IBC due to good comfort and convenience. Safety was reported as the main reason for adults using booster cushions in general, whereas children reported comfort as the most important motivation. Education is needed to ensure frequent and correct use of booster cushions in China and to raise safety awareness among children and adults. Furthermore, it is important that the booster cushions offer intuitively correct usage to a population with

  2. YALINA Booster subcritical assembly modeling and analyses

    International Nuclear Information System (INIS)

    Talamo, A.; Gohar, Y.; Aliberti, G.; Cao, Y.; Zhong, Z.; Kiyavitskaya, H.; Bournos, V.; Fokov, Y.; Routkovskaya, C.; Sadovich, S.

    2010-01-01

    Full text: Accurate simulation models of the YALINA Booster assembly of the Joint Institute for Power and Nuclear Research (JIPNR)-Sosny, Belarus have been developed by Argonne National Laboratory (ANL) of the USA. YALINA-Booster has coupled zones operating with fast and thermal neutron spectra, which requires a special attention in the modelling process. Three different uranium enrichments of 90%, 36% or 21% were used in the fast zone and 10% uranium enrichment was used in the thermal zone. Two of the most advanced Monte Carlo computer programs have been utilized for the ANL analyses: MCNP of the Los Alamos National Laboratory and MONK of the British Nuclear Fuel Limited and SERCO Assurance. The developed geometrical models for both computer programs modelled all the details of the YALINA Booster facility as described in the technical specifications defined in the International Atomic Energy Agency (IAEA) report without any geometrical approximation or material homogenization. Materials impurities and the measured material densities have been used in the models. The obtained results for the neutron multiplication factors calculated in criticality mode (keff) and in source mode (ksrc) with an external neutron source from the two Monte Carlo programs are very similar. Different external neutron sources have been investigated including californium, deuterium-deuterium (D-D), and deuterium-tritium (D-T) neutron sources. The spatial neutron flux profiles and the neutron spectra in the experimental channels were calculated. In addition, the kinetic parameters were defined including the effective delayed neutron fraction, the prompt neutron lifetime, and the neutron generation time. A new calculation methodology has been developed at ANL to simulate the pulsed neutron source experiments. In this methodology, the MCNP code is used to simulate the detector response from a single pulse of the external neutron source and a C code is used to superimpose the pulse until the

  3. LEADIR-PS: providing unprecedented SMR safety and economics

    Energy Technology Data Exchange (ETDEWEB)

    Hart, R.S., E-mail: N2i2@xplornet.ca [Northern Nuclear Industries Incorporated, Cambridge, ON (Canada)

    2015-07-01

    Northern Nuclear Industries Incorporated (N{sup 2} I{sup 2}) is developing Small Modular Reactors (SMRs) called LEADIR-PS, an acronym for LEAD-cooled Integral Reactor-Passively Safe. LEADIR-PS integrates proven technologies including TRISO fuel, Pebble Bed core and graphite moderator, with molten lead coolant in an integral pool type reactor configuration to achieve unprecedented safety and economics. Plants under development are LEADIR-PS30, producing 30 MWth, LEADIR-PS100 producing 100 MWth and LEADIR-PS300 producing 300 MWth that are focused on serving the energy demands of areas with a small electrical grid and/or process heat applications. A plant consisting of six LEADIR-PS300 reactor modules serving a common turbine-generator, called the LEADIR-PS Six-Pack, is focused on serving areas with higher energy demands and a robust electricity grid. The Gen{sup +} I LEADIR-PS plants are inherently/passively safe. There is no potential for a Loss Of Coolant Accident, a reactivity transient without shutdown, a loss of heat sink, or hydrogen generation. No active systems or operator actions are required to assure safety. The unprecedented safety of LEADIR-PS reactors avoids large exclusion radius and demanding evacuation plan requirements. LEADIR-PS, with steam conditions of 370 {sup o}C and 12 MPa can serve over 85% of the world's non-transportation process heat demands. In Canada, the electricity and process heat demands, ranging from those of remote communities and the oil sands to densely populated areas can be served by LEADIR-PS. (author)

  4. Beam tests on a proton linac booster for hadron therapy

    CERN Document Server

    De Martinis, C; Berra, P; Birattari, C; Calabretta, L; Crandall, K; Giove, D; Masullo, M R; Mauri, M; Rosso, E; Rovelli, A; Serafini, L; Szeless, Balázs; Toet, D Z; Vaccaro, Vittorio G; Weiss, M; Zennaro, R

    2002-01-01

    LIBO is a 3 GHz modular side-coupled proton linac booster designed to deliver beam energies up to 200 MeV, as required for the therapy of deep seated tumours. The injected beam of 50 to 70 MeV is produced by a cyclotron like those in several hospitals and research institutes. A full-scale prototype of the first module with an input/output energy of 62/74 MeV, respectively, was designed and built in 1999 and 2000. Full power RF tests were carried out successfully at CERN using a test facility at LIL at the end of the year 2000. In order to prove the feasibility of the acceleration process, an experimental setup with this module was installed at the INFN Laboratorio Nazionale del Sud (LNS) in Catania during 2001. The superconducting cyclotron provided the 62 MeV test beam. A compact solid-state RF modulator with a 4 MW klystron, made available by IBA-Scanditronix, was put into operation to power the linac. In this paper the main features of the accelerator are reviewed and the experimental results obtained duri...

  5. Two-year survival rates of anti-TNF-α therapy in psoriatic arthritis (PsA) patients with either polyarticular or oligoarticular PsA.

    Science.gov (United States)

    Iannone, F; Lopriore, S; Bucci, R; Scioscia, C; Anelli, M G; Notarnicola, A; Lapadula, G

    2015-05-01

    To evaluate the 2-year drug survival rates of the tumour necrosis factor (TNF)-α blockers adalimumab, etanercept, and infliximab in psoriatic arthritis (PsA) patients with either oligoarticular (oligo-PsA) or polyarticular PsA (poly-PsA). We studied a prospective cohort of 328 PsA patients with peripheral arthritis (213 with poly-PsA and 115 with oligo-PsA), beginning their first ever anti-TNF-α treatment with adalimumab, etanercept, or infliximab. The aim of the study was to evaluate the drug survival rates and possible baseline predictors at 2 years. After 24 months, persistence in therapy with the first anti-TNF-α blocker was not statistically different in the oligo-PsA (70.4%) and poly-PsA (65.7%) subsets. Predictors of drug discontinuation were female sex [hazard ratio (HR) 1.63, 95% confidence interval (CI) 1.00-2.68, p = 0.04] and starting the therapy in years 2003-8 (HR 0.51, 95% CI 0.33-0.80, p = 0.003). In poly-PsA, the persistence of etanercept (68.3%) was significantly higher than that of adalimumab (51.9%, p = 0.01), whereas in oligo-PsA no significant difference was detected. In poly-PsA, the period 2003-8 was a negative predictor (HR 0.36, 95% CI 0.21-0.62, p = 0.0001) whereas in oligo-PsA female gender was a positive predictor of drug discontinuation (HR 2.08, 95% CI 1.02-4.24, p = 0.04). With regard to clinical outcomes, the best responses in terms of European League Against Rheumatism (EULAR) 'good' response or Disease Activity Score (DAS28) remission, crude or adjusted according to the LUND Efficacy indeX (LUNDEX), were seen in patients on etanercept or infliximab. Our study provides some evidence that anti-TNF-α drugs may perform differently in PsA, and that the analysis of clinical disease subsets may improve our knowledge and promote better management of PsA.

  6. Updating the Psoriatic Arthritis (PsA) Core Domain Set: A Report from the PsA Workshop at OMERACT 2016.

    Science.gov (United States)

    Orbai, Ana-Maria; de Wit, Maarten; Mease, Philip J; Callis Duffin, Kristina; Elmamoun, Musaab; Tillett, William; Campbell, Willemina; FitzGerald, Oliver; Gladman, Dafna D; Goel, Niti; Gossec, Laure; Hoejgaard, Pil; Leung, Ying Ying; Lindsay, Chris; Strand, Vibeke; van der Heijde, Désirée M; Shea, Bev; Christensen, Robin; Coates, Laura; Eder, Lihi; McHugh, Neil; Kalyoncu, Umut; Steinkoenig, Ingrid; Ogdie, Alexis

    2017-10-01

    To include the patient perspective in accordance with the Outcome Measures in Rheumatology (OMERACT) Filter 2.0 in the updated Psoriatic Arthritis (PsA) Core Domain Set for randomized controlled trials (RCT) and longitudinal observational studies (LOS). At OMERACT 2016, research conducted to update the PsA Core Domain Set was presented and discussed in breakout groups. The updated PsA Core Domain Set was voted on and endorsed by OMERACT participants. We conducted a systematic literature review of domains measured in PsA RCT and LOS, and identified 24 domains. We conducted 24 focus groups with 130 patients from 7 countries representing 5 continents to identify patient domains. We achieved consensus through 2 rounds of separate surveys with 50 patients and 75 physicians, and a nominal group technique meeting with 12 patients and 12 physicians. We conducted a workshop and breakout groups at OMERACT 2016 in which findings were presented and discussed. The updated PsA Core Domain Set endorsed with 90% agreement by OMERACT 2016 participants included musculoskeletal disease activity, skin disease activity, fatigue, pain, patient's global assessment, physical function, health-related quality of life, and systemic inflammation, which were recommended for all RCT and LOS. These were important, but not required in all RCT and LOS: economic cost, emotional well-being, participation, and structural damage. Independence, sleep, stiffness, and treatment burden were on the research agenda. The updated PsA Core Domain Set was endorsed at OMERACT 2016. Next steps for the PsA working group include evaluation of PsA outcome measures and development of a PsA Core Outcome Measurement Set.

  7. The PS locomotive runs again

    CERN Multimedia

    2001-01-01

    Over forty years ago, the PS train entered service to steer the magnets of the accelerator into place... ... a service that was resumed last Tuesday. Left to right: Raymond Brown (CERN), Claude Tholomier (D.B.S.), Marcel Genolin (CERN), Gérard Saumade (D.B.S.), Ingo Ruehl (CERN), Olivier Carlier (D.B.S.), Patrick Poisot (D.B.S.), Christian Recour (D.B.S.). It is more than ten years since people at CERN heard the rumbling of the old PS train's steel wheels. Last Tuesday, the locomotive came back into service to be tested. It is nothing like the monstrous steel engines still running on conventional railways -just a small electric battery-driven vehicle employed on installing the magnets for the PS accelerator more than 40 years ago. To do so, it used the tracks that run round the accelerator. In fact, it is the grandfather of the LEP monorail. After PS was commissioned in 1959, the little train was used more and more rarely. This is because magnets never break down, or hardly ever! In fact, the loc...

  8. 47 CFR 73.827 - Interference to the input signals of FM translator or FM booster stations.

    Science.gov (United States)

    2010-10-01

    ... translator or FM booster stations. 73.827 Section 73.827 Telecommunication FEDERAL COMMUNICATIONS COMMISSION... Interference to the input signals of FM translator or FM booster stations. (a) An authorized LPFM station will not be permitted to continue to operate if an FM translator or FM booster station demonstrates that...

  9. Effect of reactor finiteness on the boundary condition at the surface of a booster section

    International Nuclear Information System (INIS)

    Wassef, W.A.

    1982-01-01

    Effect of reactor finiteness on the boundary condition at the surface of an absorbing booster embedded in the reactor core is studied and formulated. The model used in these calculations depends on the Pl-Transport coupling technique. This method takes into consideration the rigorous neutron transport behavior inside the booster medium, while the Pl-approximation in the bulk of the scattering medium surrounding the booster which can be considered infinite in most practical applications. The neutron flux gradient parallel to the surface of the booster is considered. The geometrical configuration of the reactor core cross section is circular or rectangular. Finiteness of the reactor is introduced in the general formulation through its dimensions or buckling. Extensive numerical results are given to demonstrate the dependence of the boundary condition at the surface of the booster section on the reactor finiteness and the different physical parameters

  10. AGS BOOSTER BEAM POSITION, TUNE, AND LONGITUDINAL PROFILE DATA ACQUISITION SYSTEM

    International Nuclear Information System (INIS)

    BROWN, K.A.; AHRENS, L.; SEVERINO, F; SMITH, K.; WILINSKI, M

    2003-01-01

    In this paper we will describe a data acquisition system designed and developed for the AGS Booster. The system was motivated by the need to get high quality beam diagnostics from the AGS Booster. This was accomplished by locating the electronics and digital data acquisition close to the Booster ring, to minimize loss of bandwidth in the original signals. In addition we had to develop the system rapidly and at a low cost. The system consists of a Lecroy digital oscilloscope which is interfaced through a National Instruments LabView(trademark) server application, developed for this project. This allows multiple client applications to time share the scope without interfering with each other. We will present a description of the system design along with example clients that we have implemented

  11. Reusable Boosters in a European-Russian Perspective

    Science.gov (United States)

    Deneu, François; Ramiandrasoa, Fabienne

    2002-01-01

    In 2001, EADS and Khrunichev SRPSC have initiated and carried out a working group devoted to the analysis of potential common studies and developments in the field of space activities. This working group came up with several propositions of interest, among which, the use of reusable boosters issued from Khrunichev previous design appeared to be promising when applied to heavy type launchers. Although the results required to be confirmed by detailed studies prior to final conclusions, preliminary studies have shown the interest of Ariane 5 configurations using such reusable booster in view of reducing the specific and launch cost as well as potentially increasing the performance. In November 2001, EADS and KHRUNICHEV SRPSC have started a study on an Ariane 5 plus reusable boosters configuration. This study aims at obtaining a better understanding of the advantages and drawbacks attached to such a use. Technical feasibility is more in depth analysed, with all recurring and not recurring aspects (including launch infrastructure modifications). Programmatic aspects are also addressed in order to better assess potential economic advantages and unavoidable drawbacks. Beyond that the identification of what could be, for western Europe and Russian players, an efficient and pay- off industrial organisation, is also a study theme of importance. This papers intends to present the main results achieved within this study and the propositions for the future which are likely to provide western Europe and Russia with stronger positions in the competitive field of launch business.

  12. Multi-Physics Analysis of the Fermilab Booster RF Cavity

    International Nuclear Information System (INIS)

    Awida, M.; Reid, J.; Yakovlev, V.; Lebedev, V.; Khabiboulline, T.; Champion, M.

    2012-01-01

    After about 40 years of operation the RF accelerating cavities in Fermilab Booster need an upgrade to improve their reliability and to increase the repetition rate in order to support a future experimental program. An increase in the repetition rate from 7 to 15 Hz entails increasing the power dissipation in the RF cavities, their ferrite loaded tuners, and HOM dampers. The increased duty factor requires careful modelling for the RF heating effects in the cavity. A multi-physic analysis investigating both the RF and thermal properties of Booster cavity under various operating conditions is presented in this paper.

  13. Booster Long 13 irradiation studies

    Energy Technology Data Exchange (ETDEWEB)

    Leveling, A.; Mokhov, N.; Moore, C.D.; /Fermilab

    1998-06-01

    Extraction from the Booster to the Main Ring occurred at Long Straight 13. The nature of the extraction process was such that 1% to 2% of the beam was lost in this region. There was an appreciable amount of beam extracted as shown in Table 1, which gives the yearly integrated intensities from 1973 to 1997. A simple model of the extraction losses was set up by Chandra Bhat utilizing the program CASIM. A sample output I shown in figure 1 which gives contours of stars/cm3 in the dirt, also schematically depicted are the three six feet deep sampling holes which were drilled to map out this cascade. One aspect of this study has been the study of the production of non-migrating nuclides and further study may in fact yield better values for the K parameter, the probability per star that an atom of the particular nuclide will be produced. Also the results of this study can give experimental numbers for the production of other nuclides when the amount of Na22 has been calculated. However, the most important part of this study has been the determination of the amount of tritium produced by extraction from the Booster and the experimentally determined migration rate. If we look at the top sample result in hole S2 of 777 pCi/ml of tritium and use the experimentally determined rate of migration and the depth to the aquifer of 13.1m, they calculate that the concentration will have decayed away to 1.1E-8 pCi/ml. If we look at the bottom sample, which is 11.3 m away from the aquifer, they calculate that the 116 pCi/ml will have decayed to 5.2E-8 pCi/ml. The conclusions is that the rate of migration determined over the 24 year irradiation history of the Booster extraction point is small enough that there is no problem with migration of tritium to the aquifer.

  14. Aspects of operation of the Fermilab Booster RF System at very high intensity

    International Nuclear Information System (INIS)

    Griffin, J.E.

    1996-04-01

    The purpose of this note is to examine the likelihood and problems associated with operation of the Fermilab Booster rf systems as it presently exists, or with only minor modifications, at beam intensity approaching 5x10 13 protons per pulse. Beam loading of the rf system at such an intensity will be one order of magnitude larger than at the present operation level. It is assumed that the injection energy will be raised to 1 GeV with no major increase in the injected energy spread (longitudinal emittance). The beam will be bunched by adiabatic capture as is presently done although it may be necessary to remove one or two bunches prior to acceleration to allow clean extraction at 8 GeV. At very high intensity the charge in each bunch will interact with the vacuum chamber impedance (and with itself) in such a way as to reduce in some cases the bucket area generated by the rf voltage. Because this decrement must be made up by changes in the rf ring voltage if the required bucket area is to be maintained, these effects must be taken into consideration in any analysis of the capability of the rf system to accelerate very large intensity

  15. Tune measurement in the NSLS booster synchrotron

    International Nuclear Information System (INIS)

    Blum, E.B.; Nawrocky, R.

    1993-01-01

    The NSLS booster synchrotron can accelerate an electron beam from approximately 80 to 750 MeV in 0.7 sec. The betatron tunes can change during acceleration by as much as 0.1 units, causing beam loss as they cross resonance lines. Precise measurements with a conventional swept spectrum analyzer have always been difficult because of the rapid variation of tune as the magnets are ramped. We are now using a system based on a Tektronix 3052 digital spectrum analyzer that can obtain a complete frequency spectrum over a 10 MHz bandwidth in 200 μsec. Betatron oscillations are stimulated for the measurements by applying white noise to the beam through stripline electrodes. We will describe the instrumentation, our measurements of tune as a function time during the acceleration cycle, and the resulting improvements to the booster operation

  16. iPS-Cinderella Story in Cell Biology

    Directory of Open Access Journals (Sweden)

    Editorial

    2010-01-01

    Full Text Available As we step through the frontiers of modern Science, we are all witnesses to the Cinderella story repeating itself in the form of the iPS. The process of re-programming adult somatic cells to derive Induced Pluripotent stem cells (iPS with the wand of transcription factors and then differentiating them back to adult somatic cells resembles the transformation of Cinderella from a Cinder girl to princess and back to a Cinder girl after the ball; but the iPS-Cinderella is the most fascinating thing ever in cell biology!From the day iPS first made its headlines when it was first produced by Shinya Yamanaka at Kyoto University in Japan, Stem Cell scientists all over the world are re- doing their experiments so far done using other sources like embryonic and adult Stem cells with the iPS cells exploring their potential to the fullest. A Stem Cell science news page without this magic word of iPS is difficult to imagine these days and Scientists have been successful in growing most of the adult Cell types from iPS cells.iPS cells was the key to solve the problems of Immune rejection and Immunosupression required when using other allogeneic Stem cell types which had baffled scientists previously. But the issues raised by scientists about the use of viruses and Oncogenes in producing iPS cells were made groundless when scientists in February 2008 published the discovery of a technique that could remove oncogenes after the induction of pluripotency and now it is possible to induce pluripotency using plasmid transfection, piggyback transposon system and piggyback transposon system combined with a non viral vector system. The word of the day is pIPS which are protein-induced Pluripotent stem cells which are iPS cells that were generated without any genetic alteration of the adult cell. This research by the group of Sheng Ding in La Jolla, California made public in April 2009 showed that the generation of poly-arginine anchors was sufficient to induce

  17. Beam current monitoring in the AGS Booster and its transfer lines

    International Nuclear Information System (INIS)

    Witkover, R.L.; Zitvogel, E.; Castillo, V.

    1991-01-01

    The new AGS Booster is designed to accelerate low intensity polarized protons and heavy ions, and high intensity protons. The wide range of beam parameters and the vacuum, thermal and radiation environment, presented challenges in the instrumentation design. This paper describes the problems and solutions for the beam current monitors in the Booster and its transport lines. Where available, results of the initial operation will be presented. 11 refs., 3 figs

  18. Study of solid rocket motors for a space shuttle booster. Volume 1: Executive summary

    Science.gov (United States)

    1972-01-01

    The design, development, production, and launch support analysis for determining the solid propellant rocket engine to be used with the space shuttle are discussed. Specific program objectives considered were: (1) definition of engine designs to satisfy the performance and configuration requirements of the various vehicle/booster concepts, (2) definition of requirements to produce booster stages at rates of 60, 40, 20, and 10 launches per year in a man-rated system, and (3) estimation of costs for the defined SRM booster stages.

  19. Controlled longitudinal emittance blow-up using band-limited phase noise in CERN PSB

    Science.gov (United States)

    Quartullo, D.; Shaposhnikova, E.; Timko, H.

    2017-07-01

    Controlled longitudinal emittance blow-up (from 1 eVs to 1.4 eVs) for LHC beams in the CERN PS Booster is currently achievied using sinusoidal phase modulation of a dedicated high-harmonic RF system. In 2021, after the LHC injectors upgrade, 3 eVs should be extracted to the PS. Even if the current method may satisfy the new requirements, it relies on low-power level RF improvements. In this paper another method of blow-up was considered, that is the injection of band-limited phase noise in the main RF system (h=1), never tried in PSB but already used in CERN SPS and LHC, under different conditions (longer cycles). This technique, which lowers the peak line density and therefore the impact of intensity effects in the PSB and the PS, can also be complementary to the present method. The longitudinal space charge, dominant in the PSB, causes significant synchrotron frequency shifts with intensity, and its effect should be taken into account. Another complication arises from the interaction of the phase loop with the injected noise, since both act on the RF phase. All these elements were studied in simulations of the PSB cycle with the BLonD code, and the required blow-up was achieved.

  20. OPTIMASI DAYA MESIN DAN KONSUMSI BAHAN BAKAR MESIN TOYOTA SERI 5K MELALUI PENGGUNAAN PENGAPIAN BOOSTER

    Directory of Open Access Journals (Sweden)

    Mardani Ali Sera

    2015-10-01

    Full Text Available Proses pembakaran adalah proses secara fisik yang terjadi di dalam silinder. Proses pembakaran dimulai pada saat busi memercikkan bunga api hingga terjadi proses pembakaran. Dalam penelitian ini digunakan metode eksperimen yaitu membandingkan daya dan konsumsi bahan bakar antara pengapian standar dengan pengapian menggunakan booster. Berdasarkan data hasil uji coba perbandingan antara sistem pengapian standar dengan pengapian yang menggunakan booster dengan objek penelitian mesin Toyota seri 5K diketahui adanya kenaikan 2.61% daya menjadi 27.723 kW dari 27.17 kW antara sistem pengapian standar dengan pengapian yang menggunakan booster pada putaran mesin 2400 rpm. Sedangkan prosentase kenaikan rerata daya sebesar 2.79 %. Penggunaan booster juga membuat penggunaan konsumsi bahan bakar spesifik (sfc antara sistem pengapian standar dengan pengapian yang menggunakan booster. Prosentase penurunan rerata konsumsi bahan bakar spesifik (sfc sebesar 6.99%. Pada sistem pengapian yang menggunakan booster, sfc minimum sebesar 0.219 kg/kWh pada putaran mesin 2200 rpm. Pada pengapian standar sfc minimum sebesar 0.231 kg/kWh pada putaran mesin 2400 rpm.

  1. Whole-body microvascular permeability of small molecules in man: clinical aspects, basic concepts and limitations of the single injection technique

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl

    1985-01-01

    In order to estimate whole-body permeability-surface area (PS) product, the initial slope of the plasma disappearance curve was determined after simultaneous i.v. injection of 24Na+ (mol.wt 24) and 51Cr-EDTA (mol.wt 342). Twelve subjects were studied. Plasma volume (PV) was measured by the indica......In order to estimate whole-body permeability-surface area (PS) product, the initial slope of the plasma disappearance curve was determined after simultaneous i.v. injection of 24Na+ (mol.wt 24) and 51Cr-EDTA (mol.wt 342). Twelve subjects were studied. Plasma volume (PV) was measured...

  2. Studies on the construction of a new 80 MeV injector and a new injection scheme for the synchrotron of the Bonn accelerator facility ELSA

    International Nuclear Information System (INIS)

    Raecke, K.

    2001-09-01

    At the ELSA Accelerator Facility exists the opportunity to install a 80 MeV linear accelerator as an injector for the 2,5 GeV Booster Synchrotron. Because of its length the new structure cannot replace one of the linacs used today so possibilities to built up the accelerator and the transfer channels are worked out. Calculations comparing the injection efficiency of the present layout and the possible new layout show a recognizable improvement. The injection efficiency can be further improved using a single turn injection scheme. A septum magnet and a fast kicker for this injection scheme is designed. (orig.)

  3. Response to booster doses of hepatitis B vaccine among young adults who had received neonatal vaccination.

    Directory of Open Access Journals (Sweden)

    Paul K S Chan

    Full Text Available Newborns who have received hepatitis B immunization in 1980s are now young adults joining healthcare disciplines. The need for booster, pre- and post-booster checks becomes a practical question.The aim of this study is to refine the HBV vaccination policy for newly admitted students in the future.A prospective study on medical and nursing school entrants to evaluate hepatitis B serostatus and the response to booster doses among young adults.Among 212 students, 17-23-year-old, born after adoption of neonatal immunization, 2 (0.9% were HBsAg positive, 40 (18.9% were anti-HBs positive. At 1 month after a single-dose booster for anti-HBs-negative students, 14.5% had anti-HBs 100 mIU/mL, respectively. The anti-HBs levels were significantly higher for females than males (mean [SD]: 431 [418] vs. 246 [339] mIU/mL, P = 0.047. At 2-4 month after the third booster dose, 97.1% had anti-HBs >100 mIU/mL and 2.9% had 10-100 mIU/mL.Pre-booster check is still worthwhile to identify carriers among newly recruited healthcare workers born after adoption of neonatal immunization. A 3-dose booster, rather than a single dose, is required for the majority to achieve an anti-HBs level >100 mIU/mL, as memory immunity has declined in a substantial proportion of individuals. Cost-effectiveness of post-booster check for anti-HBs is low and should be further evaluated based on contextual specific utilization of results.

  4. Integral Ramjet Booster Demonstration Program

    Science.gov (United States)

    1975-02-01

    vibration loads before motor firing at -65, +70, and +1650F, (2) The chambers are fabricated from roll and welded ( TIG ) L-605 sheet that is cold...Typical Integral Booster Internal Configuration Keyhole Grain Pressure and Thrust Versus Time (+700F, Sea Level) Keyhole Grain Pressure and...Thrust Versus Time (+1650F, Sea Level) Keyhole Grain Pressure and Thrust Versus Time (-65^, Sea Level) Radial-Slot Grain Design Radial-Slot Grain

  5. [Safety and immunogenicity of a 7-valent pneumococcal conjugate vaccine (Prevenar) booster dose in healthy Chinese toddlers].

    Science.gov (United States)

    Li, Rong-cheng; Li, Feng-xiang; Li, Yan-ping

    2009-06-01

    To evaluate the safety and immunogenicity of the booster dose of 7 valent pneumococcal conjugate vaccine (PCV7) to the healthy Chinese toddlers who had received 3 primary doses. Four hundred and eighty-eight Chinese toddlers received a booster dose of PCV7 at age of 12-15 months following a primary series of the vaccine given at ages 3, 4, 5 months separately with Diphtheria Tetanus Acellular Pertussis Combined Vaccine (DTaP) in Group 1 or concurrently with DTaP in Group 2. Following the booster dose immunization, each subject was followed up for 30 days to observe the safety of the vaccine. Blood samples were taken from a subset of subjects prior and post 30 days the booster dose immunization to evaluate immunogenicity. A high proportion of subjects in Group 1 (89%) and Group 2 (91%) remained afebrile after the booster dose. Local reactions to the PCV7 booster dose were generally mild. For each serotype, the rise in GMC (post-/pre-vaccination) showed a statistically significant difference (P<0.0001) between both groups. PCV7 administered as a booster dose is generally safe, well tolerate, and immunogenic in healthy Chinese toddlers.

  6. Design of the AGS Booster Beam Position Monitor electronics

    International Nuclear Information System (INIS)

    Ciardullo, D.J.; Smith, G.A.; Beadle, E.R.

    1991-01-01

    The operational requirements of the AGS Booster Beam Position Monitor system necessitate the use of electronics with wide dynamic range and broad instantaneous bandwidth. Bunch synchronization is provided by a remote timing sequencer coupled to the local ring electronics via digital fiber-optic links. The Sequencer and local ring circuitry work together to provide single turn trajectory or average orbit and intensity information, integrated over 1 to 225 bunches. Test capabilities are built in for the purpose of enhancing BPM system accuracy. This paper describes the design of the Booster Beam Position Monitor electronics, and presents performance details of the front end processing, acquisition and timing circuitry

  7. Measured longitudinal beam impedance of booster gradient magnets; TOPICAL

    International Nuclear Information System (INIS)

    James L Crisp and Brian J. Fellenz

    2001-01-01

    The Booster gradient magnets have no vacuum pipe which forces the beam image current to flow along the laminated pole tips. Both D and F style magnets were measured with a stretched wire to determine the longitudinal beam impedance caused by these laminations. Results are compared to calculations done 30 years ago. The inductive part of the magnet impedance is interesting because it partially compensates for the negative inductance effects of space charge on the beam. An R/L circuit consisting of 37K(center d ot) in parallel with between 40 and 100uH is a reasonable approximation to the total impedance of Booster magnet laminations

  8. Functional characterization of calcineurin homologs PsCNA1/PsCNB1 in Puccinia striiformis f. sp. tritici using a host-induced RNAi system.

    Directory of Open Access Journals (Sweden)

    Hong Zhang

    Full Text Available Calcineurin plays a key role in morphogenesis, pathogenesis and drug resistance in most fungi. However, the function of calcineurin genes in Puccinia striiformis f. sp. tritici (Pst is unclear. We identified and characterized the calcineurin genes PsCNA1 and PsCNB1 in Pst. Phylogenetic analyses indicate that PsCNA1 and PsCNB1 form a calcium/calmodulin regulated protein phosphatase belonging to the calcineurin heterodimers composed of subunits A and B. Quantitative RT-PCR analyses revealed that both PsCNA1 and PsCNB1 expression reached their maximum in the stage of haustorium formation, which is one day after inoculation. Using barely stripe mosaic virus (BSMV as a transient expression vector in wheat, the expression of PsCNA1 and PsCNB1 in Pst was suppressed, leading to slower extension of fungal hyphae and reduced production of urediospores. The immune-suppressive drugs cyclosporin A and FK506 markedly reduced the germination rates of urediospores, and when germination did occur, more than two germtubes were produced. These results suggest that the calcineurin signaling pathway participates in stripe rust morphogenetic differentiation, especially the formation of haustoria during the early stage of infection and during the production of urediospores. Therefore PsCNA1 and PsCNB1 can be considered important pathogenicity genes involved in the wheat-Pst interaction.

  9. Cabling design of booster and storage ring construction progress of TPS

    International Nuclear Information System (INIS)

    Wong, Y.-S.; Liu, K.-B.; Liu, C.-Y.; Wang, B.-S.

    2017-01-01

    The 2012 Taiwan Photon Source (TPS) cable construction project started after 10 months to complete the cable laying and installation of power supply. The circumference of the booster ring (BR) is 496.8 m, whereas that of the storage ring (SR) is 518.4 m. Beam current is set to 500 mA at 3.3 GeV. The paper on grounding systems discusses the design of the ground wire (< 0.2 Ω) with low impedance, power supply of the accelerator and cabling tray. The flow and size of the ground current are carefully evaluated to avoid grounded current from flowing everywhere, which causes interference problems. In the design of the TPS, special shielding will be established to isolate the effects of electromagnetic interference on the magnet and ground current. Booster ring dipoles are connected by a series of 54-magnet bending dipole; the cable size of its stranded wire measures 250 mm"2, with a total length of 5000 m. Booster ring and storage ring quadrupoles have 150 magnets; the cable size of their stranded wire is 250 mm"2, with a total length of 17000 m. Storage ring dipole consists of 48 magnets; the cable size of its stranded wire is 325 mm"2, with a total length of 6000 m. This study discusses the power supply cabling design of the storage ring and booster ring construction progress of TPS. The sections of this paper are divided into discussions of the construction of the control and instrument area, cabling layout of booster ring and storage ring, as well as the installation and commission machine. This study also discusses the use of a high-impedance meter to determine the effect of cabling insulation and TPS power supply machine on energy transfer to ensure the use of safe and correct magnet.

  10. 100-ps framing-camera tube

    International Nuclear Information System (INIS)

    Kalibjian, R.

    1978-01-01

    The optoelectronic framing-camera tube described is capable of recording two-dimensional image frames with high spatial resolution in the <100-ps range. Framing is performed by streaking a two-dimensional electron image across narrow slits. The resulting dissected electron line images from the slits are restored into framed images by a restorer deflector operating synchronously with the dissector deflector. The number of framed images on the tube's viewing screen equals the number of dissecting slits in the tube. Performance has been demonstrated in a prototype tube by recording 135-ps-duration framed images of 2.5-mm patterns at the cathode. The limitation in the framing speed is in the external drivers for the deflectors and not in the tube design characteristics. Faster frame speeds in the <100-ps range can be obtained by use of faster deflection drivers

  11. The Advanced Photon Source injection timing system

    International Nuclear Information System (INIS)

    Lenkszus, F.R.; Laird, R.

    1995-01-01

    The Advanced Photon Source consists of five accelerators. The injection timing system provides the signals required to cause a bunch emitted from the electron gun to navigate through intermediate accelerators to a specific bucket (1 out of 1296) within the storage ring. Two linacs and a positron accumulator ring operate at 60Hz while a booster synchrotron ramps and injects into the storage ring at 2Hz. The distributed, modular VME/VXI-based injection timing system is controlled by two EPICS-based input/output controllers (IOCs). Over 40 VME/VXI cards have been developed to implement the system. Card types range from 352MHz VXI timing modules to VME-based fiber optic fanouts and logic translators/drivers. All timing is distributed with fiber optics. Timing references are derived directly from machine low-level rf of 9.77MHz and 352MHz. The timing references provide triggers to programmable delay generators. Three grades of timing are provided. Precision timing is derived from commercial digital delay generators, intermediate precision timing is obtained from VXI 8-channel digital delay generators which provide timing with 25ns peak-to-peak jitter, and modest precision timing is provided by the APS event system. The timing system is fully integrated into the APS EPICS-based control system

  12. Immunogenicity and Safety of a Booster Injection of DTap-IPV//Hib (Pentaxim) Administered Concomitantly With Tetravalent Dengue Vaccine in Healthy Toddlers 15-18 Months of Age in Mexico: A Randomized Trial.

    Science.gov (United States)

    Melo, Flor Irene Rodriguez; Morales, José Juan Renteria; De Los Santos, Abiel Homero Mascareñas; Rivas, Enrique; Vigne, Claire; Noriega, Fernando

    2017-06-01

    The live, attenuated, tetravalent dengue vaccine (CYD-TDV) is licensed in a number of dengue endemic countries for individuals ≥9 years of age. Before the integration of any vaccine into childhood vaccination schedules, a lack of immune interference and acceptable safety when coadministered with other recommended vaccines should be demonstrated. This randomized, multi-center phase III trial was conducted in Mexico. Healthy toddlers (n = 732) received a booster dose of a licensed pentavalent combination vaccine [diphtheria, tetanus, acellular pertussis, inactivated polio vaccine and Haemophilus influenzae type b (DTaP-IPV//Hib)] either concomitantly or sequentially, with the second dose of CYD-TDV administered as a 3-dose schedule. Antibody titers against diphtheria toxoid, tetanus toxoid and pertussis antigens were measured by enzyme-linked immunosorbent assay. Antibodies against poliovirus and dengue serotypes were measured using a plaque reduction neutralization test. Noninferiority was demonstrated for each of the DTaP-IPV//Hib antigens if the lower limit of the 2-sided 95% confidence interval of the difference in seroconversion rates between the 2 groups (CYD-TDV and placebo) was ≥10%. Safety of both vaccines was assessed. Noninferiority in immune response was demonstrated for all DTaP-IPV//Hib antigens. After 3 doses of CYD-TDV, no difference was observed in the immune response for CYD-TDV between groups. There were no safety concerns during the study. Coadministration of the DTaP-IPV//Hib booster vaccine with CYD-TDV has no observed impact on the immunogenicity or safety profile of the DTaP-IPV//Hib booster vaccine. No difference was observed on the CYD-TDV profile when administered concomitantly or sequentially with the DTaP-IPV//Hib booster vaccine.

  13. Compensation of dogleg effect in Fermilab Booster

    CERN Document Server

    Xiao Biao Huang

    2003-01-01

    The edge focusing of dogleg magnets in Fermilab Booster has been causing severe distortion to the horizontal linear optics. The doglegs are vertical rectangular bends, therefore the vertical edge focusing is canceled by body focusing and the overall effect is focusing in the horizontal plane. The maximum horizontal beta function is changed from 7m to 46.9m and maximum dispersion from 3.19m to 6.14m. Beam size increases accordingly. This is believed to be one of the major reasons of beam loss. In this technote we demonstrate that this effect can be effectively corrected with Booster's quadrupole correctors in short straight sections (QS). There are 24 QS correctors which can alter horizontal linear optics with negligible perturbation to the vertical plane. The currents of correctors are determined by harmonic compensation, i.e., cancellation of dogleg's harmonics that are responsible for the distortion with that of QS correctors. By considering a few leading harmonics, the ideal lattice can be partly restored....

  14. PsHint1, associated with the G-protein α subunit PsGPA1, is required for the chemotaxis and pathogenicity of Phytophthora sojae.

    Science.gov (United States)

    Zhang, Xin; Zhai, Chunhua; Hua, Chenlei; Qiu, Min; Hao, Yujuan; Nie, Pingping; Ye, Wenwu; Wang, Yuanchao

    2016-02-01

    Zoospore chemotaxis to soybean isoflavones is essential in the early stages of infection by the oomycete pathogen Phytophthora sojae. Previously, we have identified a G-protein α subunit encoded by PsGPA1 which regulates the chemotaxis and pathogenicity of P. sojae. In the present study, we used affinity purification to identify PsGPA1-interacting proteins, including PsHint1, a histidine triad (HIT) domain-containing protein orthologous to human HIT nucleotide-binding protein 1 (HINT1). PsHint1 interacted with both the guanosine triphosphate (GTP)- and guanosine diphosphate (GDP)-bound forms of PsGPA1. An analysis of the gene-silenced transformants revealed that PsHint1 was involved in the chemotropic response of zoospores to the isoflavone daidzein. During interaction with a susceptible soybean cultivar, PsHint1-silenced transformants displayed significantly reduced infectious hyphal extension and caused a strong cell death in plants. In addition, the transformants displayed defective cyst germination, forming abnormal germ tubes that were highly branched and exhibited apical swelling. These results suggest that PsHint1 not only regulates chemotaxis by interacting with PsGPA1, but also participates in a Gα-independent pathway involved in the pathogenicity of P. sojae. © 2015 BSPP AND JOHN WILEY & SONS LTD.

  15. Blood Pressure Directed Booster Trainings Improve Intensive Care Unit Provider Retention of Excellent Cardiopulmonary Resuscitation Skills.

    Science.gov (United States)

    Wolfe, Heather; Maltese, Matthew R; Niles, Dana E; Fischman, Elizabeth; Legkobitova, Veronika; Leffelman, Jessica; Berg, Robert A; Nadkarni, Vinay M; Sutton, Robert M

    2015-11-01

    Brief, intermittent cardiopulmonary resuscitation (CPR) training sessions, "Booster Trainings," improve CPR skill acquisition and short-term retention. The objective of this study was to incorporate arterial blood pressure (ABP) tracings into Booster Trainings to improve CPR skill retention. We hypothesized that ABP-directed CPR "Booster Trainings" would improve intensive care unit (ICU) provider 3-month retention of excellent CPR skills without need for interval retraining. A CPR manikin creating a realistic relationship between chest compression depth and ABP was used for training/testing. Thirty-six ICU providers were randomized to brief, bedside ABP-directed CPR manikin skill retrainings: (1) Booster Plus (ABP visible during training and testing) versus (2) Booster Alone (ABP visible only during training, not testing) versus (3) control (testing, no intervention). Subjects completed skill tests pretraining (baseline), immediately after training (acquisition), and then retention was assessed at 12 hours, 3 and 6 months. The primary outcome was retention of excellent CPR skills at 3 months. Excellent CPR was defined as systolic blood pressure of 100 mm Hg or higher and compression rate 100 to 120 per minute. Overall, 14 of 24 (58%) participants acquired excellent CPR skills after their initial training (Booster Plus 75% vs 50% Booster Alone, P = 0.21). Adjusted for age, ABP-trained providers were 5.2× more likely to perform excellent CPR after the initial training (95% confidence interval [95% CI], 1.3-21.2; P = 0.02), and to retain these skills at 12 hours (adjusted odds ratio, 4.4; 95% CI, 1.3-14.9; P = 0.018) and 3 months (adjusted odds ratio, 4.1; 95% CI, 1.2-13.9; P = 0.023) when compared to baseline performance. The ABP-directed CPR booster trainings improved ICU provider 3-month retention of excellent CPR skills without the need for interval retraining.

  16. Enhanced personal protection at the PS

    CERN Multimedia

    Samuel Morier Genoud

    2013-01-01

    Pictures 03, 06, 07 08 : Pierre Ninin, deputy group leader of GS-ASE and responsible for the installation of the new PS complex safety system, in front of a new access control system.Pictures 10, 12 ,13 : View of Building 271, the future control centre of the new PS complex safety system.

  17. The PS will soon be back in operation

    CERN Multimedia

    2006-01-01

    The PS's power supply system is undergoing repairs for the accelerator to restart on 26 June. The AB Department's Power Converter Group is working flat out with Siemens to return the PS's power supply system to working order. A problem appeared on the insulation of the power cables of the rotor of the rotating machine (photo) which supplies power to the PS magnets. To prevent more significant damage to the rotating machine, the AB Department, with the approval of the CERN Management, decided to shut down the PS which had started running on 15 May. Everything is being done to restart the accelerator on 26 June. The PS's rotating machine comprises a motor coupled to a generator. The generator's rotor acts like a flywheel, supplying high-power pulses of 40 to 50 megawatts to the PS magnets. The 6 megawatt motor drives the installation at 1000 revolutions per minute and compensates only for variations in speed. It is an essential interface since it would be hard to imagine connecting such an electrical charge, p...

  18. Chronic cannabidiol treatment improves social and object recognition in double transgenic APPswe/PS1∆E9 mice.

    Science.gov (United States)

    Cheng, David; Low, Jac Kee; Logge, Warren; Garner, Brett; Karl, Tim

    2014-08-01

    Patients suffering from Alzheimer's disease (AD) exhibit a decline in cognitive abilities including an inability to recognise familiar faces. Hallmark pathological changes in AD include the aggregation of amyloid-β (Aβ), tau protein hyperphosphorylation as well as pronounced neurodegeneration, neuroinflammation, neurotoxicity and oxidative damage. The non-psychoactive phytocannabinoid cannabidiol (CBD) exerts neuroprotective, anti-oxidant and anti-inflammatory effects and promotes neurogenesis. CBD also reverses Aβ-induced spatial memory deficits in rodents. Thus we determined the therapeutic-like effects of chronic CBD treatment (20 mg/kg, daily intraperitoneal injections for 3 weeks) on the APPswe/PS1∆E9 (APPxPS1) transgenic mouse model for AD in a number of cognitive tests, including the social preference test, the novel object recognition task and the fear conditioning paradigm. We also analysed the impact of CBD on anxiety behaviours in the elevated plus maze. Vehicle-treated APPxPS1 mice demonstrated impairments in social recognition and novel object recognition compared to wild type-like mice. Chronic CBD treatment reversed these cognitive deficits in APPxPS1 mice without affecting anxiety-related behaviours. This is the first study to investigate the effect of chronic CBD treatment on cognition in an AD transgenic mouse model. Our findings suggest that CBD may have therapeutic potential for specific cognitive impairments associated with AD.

  19. Back to work for the PS

    CERN Multimedia

    2006-01-01

    On 22 June, the PS's rotating machine started turning again for the first time since its enforced shutdown one month ago (see Bulletin No. 23-24/2006) - and the PS was back in operation the very next day! A team from Siemens worked their socks off, 6 days a week for one month (including public holidays), to repair the electrical power supply in collaboration with the AB/PO Group's Main Power Converters (MPC) Section. The generator's faulty rotor was dismantled and replaced by the renovated spare rotor. The multitude of electrical and mechanical connections together with the sheer weight of the rotor (80 tonnes) made this an extremely complex job. The AB/PO Group used the shutdown to test a back-up solution for the PS power supply. The accelerator was directly wired up to the 18 kV electrical network via a 13 MVA transformer, installed at the end of the 1970s but never used. This solution succeeded in bringing the PS back into operation but at limited energy and frequency. Just 14 GeV could be achieved, whic...

  20. Synthesis and Characterization of the Rubidium Thiophosphate Rb 6 (PS 5 )(P 2 S 10 ) and the Rubidium Silver Thiophosphates Rb 2 AgPS 4 , RbAg 5 (PS 4 ) 2 and Rb 3 Ag 9 (PS 4 ) 4

    KAUST Repository

    Alahmary, Fatimah S.

    2016-02-18

    The metal thiophosphates Rb2AgPS4 (2), RbAg5(PS4)2 (3), and Rb3Ag9(PS4)4 (4) were synthesized by stoichiometric reactions, whereas Rb6(PS5)(P2S10) (1) was prepared with excess amount of sulfur. The compounds crystallize as follows: 1 monoclinic, P21/c (no. 14), a = 17.0123(7) Å, b = 6.9102(2) Å, c = 23.179(1) Å, β = 94.399(4)°; 2 triclinic, P ¯ (no. 2), a = 6.600(1) Å, b = 6.856(1) Å, c = 10.943(3) Å, α = 95.150(2)°, β = 107.338(2)°, γ = 111.383(2)°; 3 orthorhombic, Pbca (no. 61), a = 12.607(1) Å, b = 12.612(1) Å, c = 17.759(2) Å; 4 orthorhombic, Pbcm (no. 57), a = 6.3481(2) Å, b = 12.5782(4) Å, c = 35.975(1) Å. The crystal structures contain discrete units, chains, and 3D polyanionic frameworks composed of PS4 tetrahedral units arranged and connected in different manner. Compounds 1-3 melt congruently, whereas incongruent melting behavior was observed for compound 4. 1-4 are semiconductors with bandgaps between 2.3 and 2.6 eV and thermally stable up to 450 °C in an inert atmosphere. Copyright © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. High-precision calculation of loosely bound states of LiPs+ and NaPs+

    International Nuclear Information System (INIS)

    Yamashita, Takuma; Kino, Yasushi

    2015-01-01

    A positronic alkali atom would be the first step to investigate behavior of a positronium(Ps) in an external field from atoms/molecules because the system can be regarded as a simple three-body system using model potentials reflecting electron orbitals of the ion core. In order to precisely determine binding energies and structures of positronic alkali atoms (LiPs + and NaPs + ), we improve the model potential so as to reproduce highly excited atomic energy levels of alkali atoms (Li and Na). The polarization potential included by the model potential is expanded in terms of Gaussian functions to finely determine a short range part of the potential which has been assumed to be a simple form. We find better reproducibility not only of atomic levels of the alkali atoms but also of the dipole polarizability of the core ion than previous works. We construct a model potential between a positron and an ion core based on the model potential between the valence electron and ion core. Binding energies associated with a dissociation of the alkali ion core and positronium, and interparticle distances are recalculated. Our results show slightly deeper bound than other previous studies. (paper)

  2. Proposal of a beam study in the AGS Booster

    International Nuclear Information System (INIS)

    Machida, S.; Chen, S.

    1991-10-01

    IN order to achieve the design luminosity, the Superconducting Super Collider (SSC) parameter choices emphasize the preservation of the transverse emittance requiring in the collider a normalized transverse emittance of 1 π.mm.mrad. A stringent accelerator chain emittance budget must be maintained to achieve the final value. Budgeted emittance specifications for the Low Energy Booster (LEB) include 0.4 π.mm.mrad at injection and ≤ 0.6 π.mm.mrad at extraction. The space-charge tune shift is expected to be more than 0.5 when the rms normalized emittance of 0.4 π.mm.mrad at injection and the total number of particles is 1.1 x 10 12 with 1 x 10 10 particles per bunch. Therefore, it is necessary to cope with a large tune shift and avoid emittance deterioration. We have been studying the beam emittance evolution in the LEB by a multi-particle simulation code with space-charge effects. As reported in the several papers we have obtained from the simulation some new insights into the effects which seem to explain qualitatively a cause of the emittance growth. Even quantitatively, we believe that the simulation can predict the emittance growth as a function of time quite accurately because the code includes most details of the physics processes, such as the adiabatic bunching process and acceleration in the fully 6-D phase space treatment, transverse as well as longitudinal space-charge calculations in a self-consistent manner, and intensity decrease due to particle loss. The purpose of this study is to determine quantitatively the emittance deterioration due to space-charge effects, not to find the maximum current an accelerator could accommodate. Since the charge distribution itself may not remain the same, an accurate measurement of the beam profile is an essential factor of the beam study

  3. Phosphorene-directed self-assembly of asymmetric PS-b-PMMA block copolymer for perpendicularly-oriented sub-10 nm PS nanopore arrays

    Science.gov (United States)

    Zhang, Ziming; Zheng, Lu; Khurram, Muhammad; Yan, Qingfeng

    2017-10-01

    Few-layer black phosphorus, also known as phosphorene, is a new two-dimensional material which is of enormous interest for applications, mainly in electronics and optoelectronics. Herein, we for the first time employ phosphorene for directing the self-assembly of asymmetric polystyrene-block-polymethylmethacrylate (PS-b-PMMA) block copolymer (BCP) thin film to form the perpendicular orientation of sub-10 nm PS nanopore arrays in a hexagonal fashion normal to the interface. We experimentally demonstrate that none of the PS and PMMA blocks exhibit preferential affinity to the phosphorene-modified surface. Furthermore, the perpendicularly-oriented PS nanostructures almost stay unchanged with the variation of number of layers of few-layer phosphorene nanoflakes between 15-30 layers. Differing from the neutral polymer brushes which are widely used for chemical modification of the silicon substrate, phosphorene provides a novel physical way to control the interfacial interactions between the asymmetric PS-b-PMMA BCP thin film and the silicon substrate. Based on our results, it is possible to build a new scheme for producing sub-10 nm PS nanopore arrays oriented perpendicularly to the few-layer phosphorene nanoflakes. Furthermore, the nanostructural microdomains could serve as a promising nanolithography template for surface patterning of phosphorene nanoflakes.

  4. Phosphorene-directed self-assembly of asymmetric PS-b-PMMA block copolymer for perpendicularly-oriented sub-10 nm PS nanopore arrays.

    Science.gov (United States)

    Zhang, Ziming; Zheng, Lu; Khurram, Muhammad; Yan, Qingfeng

    2017-10-20

    Few-layer black phosphorus, also known as phosphorene, is a new two-dimensional material which is of enormous interest for applications, mainly in electronics and optoelectronics. Herein, we for the first time employ phosphorene for directing the self-assembly of asymmetric polystyrene-block-polymethylmethacrylate (PS-b-PMMA) block copolymer (BCP) thin film to form the perpendicular orientation of sub-10 nm PS nanopore arrays in a hexagonal fashion normal to the interface. We experimentally demonstrate that none of the PS and PMMA blocks exhibit preferential affinity to the phosphorene-modified surface. Furthermore, the perpendicularly-oriented PS nanostructures almost stay unchanged with the variation of number of layers of few-layer phosphorene nanoflakes between 15-30 layers. Differing from the neutral polymer brushes which are widely used for chemical modification of the silicon substrate, phosphorene provides a novel physical way to control the interfacial interactions between the asymmetric PS-b-PMMA BCP thin film and the silicon substrate. Based on our results, it is possible to build a new scheme for producing sub-10 nm PS nanopore arrays oriented perpendicularly to the few-layer phosphorene nanoflakes. Furthermore, the nanostructural microdomains could serve as a promising nanolithography template for surface patterning of phosphorene nanoflakes.

  5. Preliminary study of AC power feeders for AGS booster

    International Nuclear Information System (INIS)

    Meth, M.

    1992-01-01

    It has been proposed that the AGS Heavy Ion/Proton Booster be excited directly from the electric power distribution system without intervening an energy storage buffer such as an MG set or a magnetic energy buffer. The average power requirement of the AGS Booster is less than many single-loads presently housed on the lab site. However, the power swing will be the largest single pulsating load on the lab site. The large power swings will impact on the power grid producing utility-line disturbances such as voltage fluctuations and harmonic generation. Thus, it is necessary to carefully evaluate the quality of the electric power system resulting from the interconnection, such that the utility system is not degraded either on the lab site or at LILCO's substation

  6. Comparative, validity and responsiveness of the HOOS-PS and KOOS-PS to the WOMAC physical function subscale in total joint replacement for osteoarthritis

    DEFF Research Database (Denmark)

    Davis, A M; Perruccio, A V; Canizares, M

    2009-01-01

    OBJECTIVE: To evaluate the internal consistency of the Hip disability and Osteoarthritis Outcome Score-Physical Function Short-form (HOOS-PS) and the Knee injury and Osteoarthritis Outcome Score-Physical Function Short-form (KOOS-PS) in total hip replacement (THR) and total knee (TKR) replacement....... Construct validity and responsiveness were compared to the Western Ontario McMaster Universities' Osteoarthritis Index (WOMAC) Likert 3.0 physical function (PF) subscale and the PF excluding the items in the short measures (PF-exclusions). METHODS: Participants completed the full HOOS or KOOS, measures...... of fatigue, anxiety, depression and the Chronic Pain Grade (CPG) pre-surgery and the HOOS or KOOS 6 months post-surgery. Internal consistency for the HOOS-PS and KOOS-PS was calculated using Cronbach's alpha. For construct validity, it was hypothesized that correlations between the HOOS-PS or KOOS-PS and PF...

  7. Surface Micro Topography Replication in Injection Moulding

    DEFF Research Database (Denmark)

    Arlø, Uffe Rolf; Hansen, Hans Nørgaard; Kjær, Erik Michael

    2005-01-01

    The surface micro topography of injection moulded plastic parts can be important for aesthetical and technical reasons. The quality of replication of mould surface topography onto the plastic surface depends among other factors on the process conditions. A study of this relationship has been...... carried out with rough EDM (electrical discharge machining) mould surfaces, a PS grade, and by applying established three-dimensional topography parameters. Significant quantitative relationships between process parameters and topography parameters were established. It further appeared that replication...

  8. Academic Training: A walk through the LHC injector chain

    CERN Document Server

    Françoise Benz

    2005-01-01

    2004-2005 ACADEMIC TRAINING PROGRAMME LECTURE SERIES 14, 15, 16 February from 11.00 to 12.00 hrs - Main Auditorium, bldg. 500 A walk through the LHC injector chain M. BENEDIKT, P. COLLIER, K. SCHINDL /CERN-AB Proton linac, PS Booster, PS, SPS and the two transfer channels from SPS to LHC are used for LHC proton injection. The lectures will review the features of these faithful machines and underline the modifications required for the LHC era. Moreover, an overview of the LHC lead ion injector scheme from the ion source through ion linac, LEIR, PS and SPS right to the LHC entry will be given. The particular behaviour of heavy ions in the LHC will be sketched and the repercussions on the injectors will be discussed. ENSEIGNEMENT ACADEMIQUE ACADEMIC TRAINING Françoise Benz 73127 academic.training@cern.ch If you wish to participate in one of the following courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on...

  9. Liquid Rocket Booster (LRB) for the Space Transportation System (STS) Systems Study; Volume 1 - Executive Summary

    National Research Council Canada - National Science Library

    Ware, Larry

    1989-01-01

    ...) solid rocket boosters (SRBs) with liquid rocket boosters (LRBs), Figure 1.0-1. The main objectives of a LRB substitution for the SRB were increased STS safety and reliability and increased payload performance...

  10. The LLL compact 10-ps streak camera

    International Nuclear Information System (INIS)

    Thomas, S.W.; Houghton, J.W.; Tripp, G.R.; Coleman, L.W.

    1975-01-01

    The 10-ps streak camera has been redesigned to simplify its operation, reduce manufacturing costs, and improve its appearance. The electronics have been simplified, a film indexer added, and a contacted slit has been evaluated. Data support a 10-ps resolution. (author)

  11. PS, SL and LHC Auditoria change names

    CERN Multimedia

    2003-01-01

    Following the replacement of the PS, SL and LHC Divisions by the AB and AT Divisions, the Auditoria are also changing their names. PS Auditorium is renamed AB Meyrin SL Auditorium is renamed AB Prévessin LHC Auditorium is renamed AT

  12. Misuse of booster cushions - an observation study of children's performance during buckling up.

    Science.gov (United States)

    Osvalder, Anna-Lisa; Bohman, Katarina

    2008-10-01

    Booster cushions are effective tools to protect children from injuries in car crashes, but there remains a large amount of misuse. The aim of this study was to assess potential misuse of booster cushions in an observational laboratory study, and to identify whether booster cushion design, age or clothing had any effect. 130 Swedish children from the ages of 4-12 years participated. Each child buckled up on an integrated and on an aftermarket booster cushion in the rear seat. The older children also buckled up with seat belt only. Interviews, observations and body measurements were performed. Time to buckle up and amount of belt slack were registered. Photographs were taken to document misuse. Results showed that 77% failed to perform correct belt routing on the aftermarket cushion, independent of age, although they were familiar with this system. The misuse rate for the integrated cushion was only 4%. No misuse was found for seat belt only. Few children tightened the belt. The belt slack increased when wearing winter jackets. This indicates the importance of adding pretensioners to the rear seat. Sled tests with HIII&TNO 6y dummies were also performed for the most frequent misuse situations found. The main conclusion is that an integrated booster cushion has many advantages compared to an aftermarket cushion regarding both safety and comfort. It is easy and quick to handle, has few possibilities for misuse, has an intuitive design, the buckling up sequence is equal to buckling up with an ordinary seat belt, and younger children can buckle up correctly.

  13. Integrated hydraulic booster/tool string technology for unfreezing of stuck downhole strings in horizontal wells

    Science.gov (United States)

    Tian, Q. Z.

    2017-12-01

    It is common to use a jarring tool to unfreeze stuck downhole string. However, in a horizontal well, influenced by the friction caused by the deviated section, jarring effect is poor; on the other hand, the forcing point can be located in the horizontal section by a hydraulic booster and the friction can be reduced, but it is time-consuming and easy to break downhole string using a large-tonnage and constant pull force. A hydraulic booster - jar tool string has been developed for unfreezing operation in horizontal wells. The technical solution involves three elements: a two-stage parallel spring cylinder structure for increasing the energy storage capacity of spring accelerators; multiple groups of spring accelerators connected in series to increase the working stroke; a hydraulic booster intensifying jarring force. The integrated unfreezing tool string based on these three elements can effectively overcome the friction caused by a deviated borehole, and thus unfreeze a stuck string with the interaction of the hydraulic booster and the mechanical jar which form an alternatively dynamic load. Experimental results show that the jarring performance parameters of the hydraulic booster-jar unfreezing tool string for the horizontal wells are in accordance with original design requirements. Then field technical parameters were developed based on numerical simulation and experimental data. Field application shows that the hydraulic booster-jar unfreezing tool string is effective to free stuck downhole tools in a horizontal well, and it reduces hook load by 80% and lessens the requirement of workover equipment. This provides a new technology to unfreeze stuck downhole string in a horizontal well.

  14. Human hair follicle pluripotent stem (hfPS) cells promote regeneration of peripheral-nerve injury: an advantageous alternative to ES and iPS cells.

    Science.gov (United States)

    Amoh, Yasuyuki; Kanoh, Maho; Niiyama, Shiro; Hamada, Yuko; Kawahara, Katsumasa; Sato, Yuichi; Hoffman, Robert M; Katsuoka, Kensei

    2009-08-01

    The optimal source of stem cells for regenerative medicine is a major question. Embryonic stem (ES) cells have shown promise for pluripotency but have ethical issues and potential to form teratomas. Pluripotent stem cells have been produced from skin cells by either viral-, plasmid- or transposon-mediated gene transfer. These stem cells have been termed induced pluripotent stem cells or iPS cells. iPS cells may also have malignant potential and are inefficiently produced. Embryonic stem cells may not be suited for individualized therapy, since they can undergo immunologic rejection. To address these fundamental problems, our group is developing hair follicle pluripotent stem (hfPS) cells. Our previous studies have shown that mouse hfPS cells can differentiate to neurons, glial cells in vitro, and other cell types, and can promote nerve and spinal cord regeneration in vivo. hfPS cells are located above the hair follicle bulge in what we have termed the hfPS cell area (hfPSA) and are nestin positive and keratin 15 (K-15) negative. Human hfPS cells can also differentiate into neurons, glia, keratinocytes, smooth muscle cells, and melanocytes in vitro. In the present study, human hfPS cells were transplanted in the severed sciatic nerve of the mouse where they differentiated into glial fibrillary-acidic-protein (GFAP)-positive Schwann cells and promoted the recovery of pre-existing axons, leading to nerve generation. The regenerated nerve recovered function and, upon electrical stimulation, contracted the gastrocnemius muscle. The hfPS cells can be readily isolated from the human scalp, thereby providing an accessible, autologous and safe source of stem cells for regenerative medicine that have important advantages over ES or iPS cells. (c) 2009 Wiley-Liss, Inc.

  15. Psühhodraama - spontaansuse kool / Taimi Elenurm

    Index Scriptorium Estoniae

    Elenurm, Taimi

    2010-01-01

    Viinis ja New Yorgis tegutsenud psühhiaatri Jakob Levy Moreno loodud psühhodraamast, mis võimaldab rollimängu kaudu näha ennast läbi teiste silmade, aga ka vabaneda pingetest andes võimaluse käituda teisiti kui tavaelus

  16. Present state of tandem superconductive booster of JAERI

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, Suehiro; Matsuda, Makoto; Kanazawa, Shuhei; Yoshida, Tadashi; Ouchi, Isao; Shoji, Tokio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1996-12-01

    The superconductive booster constructed rear-stage accelerator of the tandem accelerator of the Tokai Research Establishment, JAERI (Japan Atomic Energy Research Institute), was completed in construction of its whole system on October, 1993, and through its beam accelerating test and remodulation its design characteristics were established on September, 1994. From November, 1994 to April, 1995 a repulsion-forming nuclear isolation apparatus was installed to modulate at target room, and was begun to use on June, 1995. The beam reaccelerated at the booster was used mainly for nuclear spectroscopy experiment, a collaborative research was developed using mini-crystal balls made by collecting from University of Tsukuba and so forth. The accelerating part of the booster is a phase independent setting type Linac consisting of 40 niobium superconducting holes with 1/4 wave-length type and 130 MHz in frequency, in which a hole can form 5 MV/m of accelerating electric field for 4 W of radio frequency spent power of 0.75 MV of accelerating voltage per hole, to form 30 MV of voltage in a whole. 4 holes are contained into each 10 cryostats, respectively. In accelerating tests, Si, Cl, Ni, Ge, Ag, I and Au ions are accelerated to establish 30 mV of total accelerating voltage in its design value, which reaches to their expected energy characteristics. Its used days in this year are 25 days after beginning of its use, and operating days of the cooling apparatus was 135 days in total. (G.K.)

  17. Concentrated Ground Plane Booster Antenna Technology for Multiband Operation in Handset Devices

    Directory of Open Access Journals (Sweden)

    C. Picher

    2014-12-01

    Full Text Available The current demand in the handset antenna field requires multiband antennas due to the existence of multiple communication standards and the emergence of new ones. At the same time, antennas with reduced dimensions are strongly required in order to be easily integrated. In this sense, the paper proposes a compact radiating system that uses two non-resonant elements to properly excite the ground plane to solve the abovementioned shortcomings by minimizing the required Printed Circuit Board (PCB area while ensuring a multiband performance. These non-resonant elements are called here ground plane boosters since they excite an efficient mode of the ground plane. The proposed radiating system comprises two ground plane boosters of small dimensions of 5 mm x 5 mm x 5 mm. One is in charge of the low frequency region (0.824-0.960 GHz and the other is in charge of the high frequency region (1.710-2.170 GHz. With the aim of achieving a compact configuration, the two boosters are placed close to each other in a corner of the ground plane of a handset device (concentrated architecture. Several experiments related to the coupling between boosters have been carried out in two different platforms (barphone and smartphone, and the best position and the required matching network are presented. The novel proposal achieves multiband performance at GSM850/900/1800/1900 and UMTS.

  18. The TDCpix readout ASIC: A 75 ps resolution timing front-end for the NA62 Gigatracker hybrid pixel detector

    Energy Technology Data Exchange (ETDEWEB)

    Kluge, A., E-mail: alexander.kluge@cern.ch; Aglieri Rinella, G.; Bonacini, S.; Jarron, P.; Kaplon, J.; Morel, M.; Noy, M.; Perktold, L.; Poltorak, K.

    2013-12-21

    The TDCpix is a novel pixel readout ASIC for the NA62 Gigatracker detector. NA62 is a new experiment being installed at the CERN Super Proton Synchrotron. Its Gigatracker detector shall provide on-beam tracking and time stamping of individual particles with a time resolution of 150 ps rms. It will consist of three tracking stations, each with one hybrid pixel sensor. The peak flow of particles crossing the detector modules reaches 1.27 MHz/mm{sup 2} for a total rate of about 0.75 GHz. Ten TDCpix chips will be bump-bonded to every silicon pixel sensor. Each chip shall perform time stamping of 100 M particle hits per second with a detection efficiency above 99% and a timing accuracy better than 200 ps rms for an overall three-station-setup time resolution of better than 150 ps. The TDCpix chip has been designed in a 130 nm CMOS technology. It will feature 45×40 square pixels of 300×300μm{sup 2} and a complex End of Column peripheral region including an array of TDCs based on DLLs, four high speed serializers, a low-jitter PLL, readout and control circuits. This contribution will describe the complete design of the final TDCpix ASIC. It will discuss design choices, the challenges faced and some of the lessons learned. Furthermore, experimental results from the testing of circuit prototypes will be presented. These demonstrate the achievement of key performance figures such as a time resolution of the processing chain of 75 ps rms with a laser sent to the center of the pixel and the capability of time stamping charged particles with an overall resolution below 200 ps rms. -- Highlights: • Feasibility demonstration of a silicon pixel detector with sub-ns time tagging capability. • Demonstrator detector assembly with a time resolution of 75 ps RMS with laser charge injection; 170 ps RMS with particle beam. • Design of trigger-less TDCpix ASIC with 1800 pixels, 720 TDC channels and 4 3.2 Gbit/s serializers.

  19. History of the ZGS 500 MeV booster.

    Energy Technology Data Exchange (ETDEWEB)

    Simpson, J.; Martin; R.; Kustom, R.

    2006-05-09

    The history of the design and construction of the Argonne 500 MeV booster proton synchrotron from 1969 to 1982 is described. This accelerator has since been in steady use for the past 25 years to power the Argonne Intense Pulsed Neutron Source (IPNS).

  20. Ps 22 in Gospels’ interpretation of Passion

    Directory of Open Access Journals (Sweden)

    Sylwester Jędrzejewski

    2012-09-01

    Full Text Available Ps 22 is a piece of artistically high poetry, clear images and metaphors, historical and prophetic references. The conviction of biblical scholars that the New Testament writers has recognized in Ps 22 prophetic witness of passion, accompanies the Church from its beginnings. The words of Jesus on the cross, taken from Ps 22: 2, have a character of lamentable re-symbolization of the prayer of Israel. These words establish a theological answer in the form of suitable credo as well. Dramatic question “why?” is connected with a proclamation and identification “My God”. The personal experience of oppression and death is included by Jesus in the history of his nation and in the experience of God. Ps 22 in the Gospels’ passion context becomes a proclamation form of prayer and a very personal, expressed in such dramatic circumstances confession of the faith.

  1. Improving the performance of booster heat pumps using zeotropic mixtures

    DEFF Research Database (Denmark)

    Zühlsdorf, B.; Meesenburg, W.; Ommen, T. S.

    2018-01-01

    Abstract This study demonstrated an increase in the thermodynamic performance of a booster heat pump, which was achieved by choosing the working fluid among pure and mixed fluids. The booster heat pump was integrated in an ultra-low-temperature district heating network with a forward temperature...... of 40 °C to produce domestic hot water, by heating part of the forward stream to 60 °C, while cooling the remaining part to the return temperature of 25 °C. The screening of working fluids considered 18 pure working fluids and all possible binary mixtures of these fluids. The most promising solutions...... heat supply system while being economically competitive to pure fluids....

  2. Real-life experience of using conventional disease-modifying anti-rheumatic drugs (DMARDs) in psoriatic arthritis (PsA). Retrospective analysis of the efficacy of methotrexate, sulfasalazine, and leflunomide in PsA in comparison to spondyloarthritides other than PsA and literature review of the use of conventional DMARDs in PsA

    Science.gov (United States)

    Roussou, Euthalia; Bouraoui, Aicha

    2017-01-01

    Objective With the aim of assessing the response to treatment with conventional disease-modifying anti-rheumatic drugs (DMARDs) used in patients with psoriatic arthritis (PsA), data on methotrexate, sulfasalazine (SSZ), and leflunomide were analyzed from baseline and subsequent follow-up (FU) questionnaires completed by patients with either PsA or other spondyloarthritides (SpAs). Material and Methods A single-center real-life retrospective analysis was performed by obtaining clinical data via questionnaires administered before and after treatment. The indices used were erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) level, Bath Ankylosing Spondylitis Disease Activity Index (BASDAI), Bath Ankylosing Spondylitis Function Index (BASFI), wellbeing (WB), and treatment effect (TxE). The indices measured at baseline were compared with those measured on one occasion in a FU visit at least 1 year later. Results A total of 73 patients, 51 with PsA (mean age 49.8±12.8 years; male-to-female ratio [M:F]=18:33) and 22 with other SpAs (mean age 50.6±16 years; M:F=2:20), were studied. BASDAI, BASFI, and WB displayed consistent improvements during FU assessments in both PsA patients and controls in comparison to baseline values. SSZ exhibited better efficacy as confirmed by TxE in both PsA patients and controls. ESR and CRP displayed no differences in either the PsA or the SpA group between the cases before and after treatment. Conclusion Real-life retrospective analysis of three DMARDs used in PsA (and SpAs other than PsA) demonstrated that all three DMARDs that were used brought about improvements in BASDAI, BASFI, TxE, and WB. However, the greatest improvements at FU were seen with SSZ use in both PsA and control cohorts. PMID:28293446

  3. A FET based kicker for a charge booster for the TRIUMF ISAC project

    International Nuclear Information System (INIS)

    Barnes, M.J.; Wait, G.D.

    2001-07-01

    A charge booster unit is required as part of an upgrade to the ISAC facility at TRIUMF. ISAC is an isotope separator coupled to an accelerator. ISAC is presently capable of accelerating only isotopes with atomic mass up to 30. The charge booster will allow ISAC to accelerate all the masses in the periodic table. A fast kicker system has been built to study the characteristics of an existing charge booster, designed by ISN in Grenoble, to assess the suitability of using this charge booster at TRIUMF. This fast kicker will subsequently be used in the TRIUMF ISAC facility for time of flight separation of the chosen charge and to recycle the higher and lower charges back to the charge booster. This will increase the efficiency from 10% to 60%. The kicker system includes a pair of deflector plates. One plate is charged up to -3.5 kV by a PET based modulator, while the other plate is held at ground potential. The modulator consists of two stacks of FETs operating in push pull with variable output voltage, pulse width, and repetition rate from virtually DC to 52 kHz. The measured high voltage output pulse rise and fall times are 63 ns and the minimum pulse width is 350 ns. The maximum pulse width is dependent upon the repetition rate. The large dynamic range for the repetition rate and pulse width required a novel circuit design and control technique, which also resulted in an energy efficient kicker system. This paper describes the design of the kicker system and shows the results of measurements. (author)

  4. Frequency control of RF booster cavity in TRIUMF

    International Nuclear Information System (INIS)

    Fong, K.; Laverty, M.

    1993-01-01

    A booster is used in the TRIUMF cyclotron to increase the energy gain per turn for beam orbits corresponding to energies greater than 370 MeV. It operates at 92.24 MHz, the 4 th harmonic of the cyclotron main rf, and at a nominal voltage of 150 kV. Excitation is provided by a 90 kW rf system that is phase locked to the main rf. When the main rf is interrupted due to sparking or other causes, a controller built into the low frequency source of the booster rf system disables the phase-locked loop, and reconfigures the source as a temperature stabilized oscillator operating at the last locked frequency. When the cyclotron rf is restored it usually will be at different frequency. The oscillator tunes automatically to this new frequency. The acquisition time is extended by the controller to match the response time of the mechanical tuner in the cavity

  5. 75 FR 63766 - Digital Low Power Television, Television Translator, and Television Booster Stations and Digital...

    Science.gov (United States)

    2010-10-18

    ...] Digital Low Power Television, Television Translator, and Television Booster Stations and Digital Class A... TV, TV Translator or TV Booster Station, FCC Form 346; 47 CFR 74.793(d); LPTV Out-of-Core Digital... collection requirements: 47 CFR 74.793(d) proposes that certain digital low power and TV translator stations...

  6. Comparison of Low-, Moderate-, and High-Molecular-Weight Hyaluronic Acid Injections in Delaying Time to Knee Surgery.

    Science.gov (United States)

    Shewale, Anand R; Barnes, Charles L; Fischbach, Lori A; Ounpraseuth, Songthip T; Painter, Jacob T; Martin, Bradley C

    2017-10-01

    We compared the effectiveness of low-molecular-weight (MW) hyaluronic acid (HA) injections (LMWHA), moderate-MW HA injections (MMWHA), and high-MW HA injections (HMWHA) for prevention or delay of knee surgery in patients with knee osteoarthritis. An observational cohort study using LifeLink Plus claims (2006-2015) was used. The primary outcome measure of the study included all surgical interventions of the knee. The secondary outcome measures were the following: (1) unicompartmental knee arthroplasty or total knee arthroplasty and (2) total knee arthroplasty only. A high-dimensional propensity score (hdPS) using 1:1 matching was used to adjust for confounding. The likelihood of each outcome was assessed using Cox proportional hazard models. A cohort of 30,417 incident HA users with knee osteoarthritis met our inclusion-exclusion criteria. There was no difference in the likelihood of composite surgical events between LMWHA users (hazard ratio, 0.939; 95% confidence interval, 0.870-1.013) and MMWHA users (hazard ratio, 1.032; 95% confidence interval, 0.952-1.119) when compared with HMWHA users in a matched hdPS analysis. However, a significantly lower likelihood for all outcome measures was demonstrated in LMWHA and MMWHA users compared with HMWHA users when hdPS was not used. There was no significant difference in the likelihood of surgical interventions between LMWHA, MMWHA, and HMWHA users after accounting for empirically derived confounders. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. SNS RING STUDY AT THE AGS BOOSTER.

    Energy Technology Data Exchange (ETDEWEB)

    ZHANG, S.Y.; AHRENS, L.; BEEBE-WANG, J.; BLASKIEWICZ, M.; FEDOTOV, A.; GARDNER, C.; LEE, Y.Y.; LUCCIO, A.; MALITSKY, N.; ROSER, T.; WENG, W.T.; WEI, J.; ZENO, K.; REECE, K.; WANG, J.G.

    2000-06-30

    During the g-2 run at the BNL AGS in early 2000, a 200 MeV storage-ring-like magnetic cycle has been set-up and tuned at the Booster in preparing for the Spallation Neutron Source (SNS) accumulator ring study. In this article, we report the progress of the machine set-up, tuning, some preliminary studies, and the future plan.

  8. Updating the Psoriatic Arthritis (PsA) Core Domain Set

    DEFF Research Database (Denmark)

    Orbai, Ana-Maria; de Wit, Maarten; Mease, Philip J

    2017-01-01

    OBJECTIVE: To include the patient perspective in accordance with the Outcome Measures in Rheumatology (OMERACT) Filter 2.0 in the updated Psoriatic Arthritis (PsA) Core Domain Set for randomized controlled trials (RCT) and longitudinal observational studies (LOS). METHODS: At OMERACT 2016, research...... conducted to update the PsA Core Domain Set was presented and discussed in breakout groups. The updated PsA Core Domain Set was voted on and endorsed by OMERACT participants. RESULTS: We conducted a systematic literature review of domains measured in PsA RCT and LOS, and identified 24 domains. We conducted...... and breakout groups at OMERACT 2016 in which findings were presented and discussed. The updated PsA Core Domain Set endorsed with 90% agreement by OMERACT 2016 participants included musculoskeletal disease activity, skin disease activity, fatigue, pain, patient's global assessment, physical function, health...

  9. NaPdPS{sub 4} and RbPdPS{sub 4}: systems with infinite straight ((1)/({infinity}))[PdPS{sub 4}]{sup -} chains soluble in polar solvents and the structure of cubic RbPdPS{sub 4}{l_brace}Rb{sub 0.33}P{sub 0.4}S{sub 2.23}O{sub x}{r_brace}

    Energy Technology Data Exchange (ETDEWEB)

    Coste, Servane; Hanko, Jason; Bujoli-Doeuff, Martine; Louarn, Guy; Evain, Michel; Brec, Raymond; Alonso, Bruno; Jobic, S; Kanatzidis, Mercouri G

    2003-11-01

    The synthesis, crystal structures, chemical and spectroscopic properties of NaPdPS{sub 4}, RbPdPS{sub 4}, and RbPdPS{sub 4}{l_brace}Rb{sub 0.33}P{sub 0.4}S{sub 2.23}O{sub x}{r_brace} are described. NaPdPS{sub 4}, RbPdPS{sub 4}, are isostructural and crystallize in the tetragonal system I4/mcm with cell parameters a=7.3074(8) A, c=12.2308(14) A and a=8.2954(3) A, c=12.2284(4) A respectively. RbPdPS{sub 4}{l_brace}Rb{sub 0.33}P{sub 0.4}S{sub 2.23}O{sub x}{r_brace} is cubic, space group Pm-3n and a=12.0042(2) A. All compounds contain the same ((1)/({infinity}))[PdPS{sub 4}]{sup -} chains made of alternating square planar Pd{sup 2+} cations and tetrahedral [PS{sub 4}]{sup 3-} anions. RbPdPS{sub 4}{l_brace}Rb{sub 0.33}P{sub 0.4}S{sub 2.23}O{sub x}{r_brace} contains co-crystallized highly disordered molecular species encapsulated within [Rb{sub 8}] cubic cavities. Spectroscopic solid state {sup 31}P NMR, infrared and Raman data as well as elemental analysis suggest that these species could be S{sub n}{sup 2-} (n=3 or 4) anions and possibly cationic [P{sub 4}S{sub 6}O]{sup 6+} fragments. NaPdPS{sub 4} and RbPdPS{sub 4} exhibit exfoliative dissolution in polar solvents giving rise to solutions that show signs of complex fluid behavior.

  10. Superconducting linac booster

    International Nuclear Information System (INIS)

    Srinivasan, B.; Betigeri, M.G.; Pandey, M.K.; Pillay, R.G.; Kurup, M.B.

    1997-01-01

    The report on superconducting LINAC booster, which is a joint project of Bhabha Atomic Research Centre (BARC) and Tata Institute of Fundamental Research (TIFR), brings out the work accomplished so far towards the development of the technology of superconducting LINAC to boost the energy of ions from the 14UD Pelletron. The LINAC is modular in construction with each module comprising of a helium cryostat housing four lead-plated quarter wave resonators. The resonators are superconducting for temperatures below 7.19K. An energy boost of 2 MeV/q per module is expected to be achieved. The first module and the post-tandem superbuncher have been fabricated and tested on the LINAC beam line. This report gives a summary of the technological achievements and also brings out the difficulties encountered during the R and D phase. (author)

  11. 76 FR 44821 - Digital Low Power Television, Television Translator, and Television Booster Stations and To Amend...

    Science.gov (United States)

    2011-07-27

    ...] Digital Low Power Television, Television Translator, and Television Booster Stations and To Amend Rules... Digital Low Power Television, Television Translator, and Television Booster Stations and to Amend Rules... translator facilities in the 700 MHz band. These provisions provide procedures for a primary wireless...

  12. 76 FR 72849 - Digital Low Power Television, Television Translator, and Television Booster Stations and To Amend...

    Science.gov (United States)

    2011-11-28

    ...] Digital Low Power Television, Television Translator, and Television Booster Stations and To Amend Rules... for Digital Low Power Television, Television Translator, and Television Booster Stations and to Amend... television, TV translator, and Class A television station DTV licensees''). The Commission has also revised...

  13. An HDAC2-TET1 switch at distinct chromatin regions significantly promotes the maturation of pre-iPS to iPS cells

    Science.gov (United States)

    Wei, Tingyi; Chen, Wen; Wang, Xiukun; Zhang, Man; Chen, Jiayu; Zhu, Songcheng; Chen, Long; Yang, Dandan; Wang, Guiying; Jia, Wenwen; Yu, Yangyang; Duan, Tao; Wu, Minjuan; Liu, Houqi; Gao, Shaorong; Kang, Jiuhong

    2015-01-01

    The maturation of induced pluripotent stem cells (iPS) is one of the limiting steps of somatic cell reprogramming, but the underlying mechanism is largely unknown. Here, we reported that knockdown of histone deacetylase 2 (HDAC2) specifically promoted the maturation of iPS cells. Further studies showed that HDAC2 knockdown significantly increased histone acetylation, facilitated TET1 binding and DNA demethylation at the promoters of iPS cell maturation-related genes during the transition of pre-iPS cells to a fully reprogrammed state. We also found that HDAC2 competed with TET1 in the binding of the RbAp46 protein at the promoters of maturation genes and knockdown of TET1 markedly prevented the activation of these genes. Collectively, our data not only demonstrated a novel intrinsic mechanism that the HDAC2-TET1 switch critically regulates iPS cell maturation, but also revealed an underlying mechanism of the interplay between histone acetylation and DNA demethylation in gene regulation. PMID:25934799

  14. Power supply for 700 MeV booster ring dipole and quadrupole magnets

    International Nuclear Information System (INIS)

    Thipsay, A.P.; Kotaiah, S.; Ramamurthi, S.S.

    1993-01-01

    The power supply to energize main coils of the booster dipole and quadrupole magnets which are connected in series is discussed. The current in this coils is increased from 28.6 Amps at injection energy (20 MeV) to 1000 Amps at the extraction energy (700 MeV) in 0.2 sec with a stability of 0.1%. Current is maintained at 1000 Amps for 0.05 to 0.166 sec with 0.02% stability after which the current is brought down fast to the injection energy level to get the required repetition rate of 2 Hz. The rectifier stage uses four fully controlled thyristorised bridges connected in series which are switched selectively at different times to get the required trapezoidal current waveform. In the ramp down period, all the bridges are operated in the inverter mode, whereby the stored energy in the magnets is fed back to the mains. An inductor and a capacitor is used as a passive filter to attenuate the voltage ripple to the rectifier. Two capacitor banks in the passive filter are switched selectively while ramping and flat top periods to reduce the error in current within tolerable limits. An active filter is used to further reduce ripple current in magnets. The current control circuit is characterized by two loops, one with voltage feedback and the other with a current feedback. A feed forward correction is also given in the voltage feedback loop to account for the charge in the inductance of the magnets at different current levels. (author). 2 figs

  15. Superconducting LINAC booster for the pelletron accelerator at Bombay

    International Nuclear Information System (INIS)

    Pillay, R.G.; Kurup, M.B.; Jain, A.K.; Biswas, D.; Kori, S.A.; Srinivasan, B.

    1989-01-01

    A superconducting heavy ion linear accelerator being constructed as a booster for the 14 UD pelletron installed recently at Bombay. The work involved in this project and the progress made so far are reviewed. (author). 15 refs., 8 figs

  16. PS overcomes two serious magnet failures

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    Two magnets and a bus bar connection in the PS were found to be faulty during high-voltage tests at the end of the accelerator shutdown. A five-week repair schedule was quickly devised. A team of mechanics, technicians and engineers worked at full speed to replace the faulty magnets, succeeding in limiting the delay of the accelerators' spring start-up to two weeks. Here we see the PS magnet string awaiting the replacement no. 6 magnet.

  17. PS Control Room

    CERN Multimedia

    CERN PhotoLab

    1963-01-01

    The good old PS Control Room, all manual. For each parameter, a knob or a button to control it; for each, a light or meter or oscilloscope to monitor it; carefully written pages serve as the data bank; phones and intercom for communication. D.Dekkers is at the microphone, M.Valvini sits in front.

  18. Simulation of the injection damping and resonance correction systems for the HEB of the SSC

    Energy Technology Data Exchange (ETDEWEB)

    Li, M.; Zhang, P.; Machida, S.

    1993-02-01

    An injection damping and resonance correction system for the High Energy Booster (HEB) of the Superconducting Super Collider (SSC) was investigated by means of multiparticle tracking. For an injection damping study, the code Simpsons is modified to utilize two Beam Position Monitors (BPM) and two dampers. ne particles of 200 Gev/c, numbered 1024 or more, with Gaussian distribution in 6-D phase space are injected into the HEB with certain injection offsets. The whole bunch of particles is then kicked in proportion to the BPM signals with some upper limit. Tracking these particles up to several hundred turn while the damping system is acting shows the turn-by-turn emittance growth, which is caused by the tune spread due to nonlinearity of the lattice and residual chromaticity with synchrotron oscillations. For a resonance correction study, the operating tune is scanned as a function of time so that a bunch goes through a resonance. The performance of the resonance correction system is demonstrated. We optimize the system parameters which satisfy the emittance budget of the HEB, taking into account the realistic hardware requirement.

  19. Simulation of the injection damping and resonance correction systems for the HEB of the SSC

    Energy Technology Data Exchange (ETDEWEB)

    Li, M.; Zhang, P.; Machida, S. (Superconducting Super Collider Laboratory, Dallas, Texas 75237 (United States))

    1993-12-25

    An injection damping and resonance correction system for the High Energy Booster (HEB) of the Superconducting Super Collider (SSC) was investigated by means of multiparticle tracking. For an injection damping study, the code Simpsons is modified to utilize two Beam Position Monitors (BPM) and two dampers. The particles of 200 Gev/c, numbered 1024 or more, with Gaussian distribution in 6-D phase space are injected into the HEB with certain injection offsets. The whole bunch of particles is then kicked in proportion to the BPM signals with some upper limit. Tracking these particles up to several hundred turns while the damping system is acting shows the turn-by-turn emittance growth, which is caused by the tune spread due to nonlinearity of the lattice and residual chromaticity with synchrotron oscillations. For a resonance correction study, the operating tune is scanned as a function of time so that a bunch goes through a resonance. The performance of the resonance correction system is demonstrated. We optimize the system parameters which satisfy the emittance budget of the HEB, taking into account the realistic hardware requirement.

  20. Prognostic significance of cytosolic pS2 content in ovarian tumors

    International Nuclear Information System (INIS)

    Raigoso, P.; Allende, T.; Zeidan, N.; Llana, B.; Bernardo, L.; Roiz, C.; Tejuca, S.; Vazquez, J.; Lamelas, M.L.

    2002-01-01

    Aim: pS2 is an estrogen regulated peptide which has been associated with a good prognosis an with a more favorable response to treatment in breast cancer patients. In ovarian tumors, the expression of pS2 was demonstrated at both mRNA and protein levels. In addition, it has been showed significant association of pS2 with mucinous differentiation or well differentiation grade of the tumors. However, it is little know about the prognostic significance of the pS2 content in ovarian carcinomas. The aims of the present work were to analyze the cytosolic pS2 content in benign and malignant ovarian tumors, its relationship with clinico-pathologic parameters, steroid receptor status, and prognostic significance. Material and Methods: We analysed the cytosolic concentrations of pS2 in 91 specimen ovarian tissues by an immunoradiometric assay (ELSA-pS2, CIS, France). The tissues were 8 normal ovaries, 43 benign tumors and 40 malignant ovarian tumors. The same ovarian tissues processed to pS2 were analyzed to Estrogen (ER) and Progesterone (PgR) Receptor status. These steroid receptors were quantified biochemically following commercial ELISA method (ABBOTT Diagnostics, Germany). The relationship between cytosolic content and clinico-pathologic factors was examined by the Mann-Whitney or Kruskall-Wallis test. Correlation between steroid receptors and pS2 content was calculated with the Spearman test. Survival curves were calculated using the Kaplan-Meier method and compared by the log-rank test. Differences were considered significant at 5% probability level. Results: pS2 could be detected in 30 cases (32.9%) with values ranged from 0.04 to 89 ng/mg prt. Only one normal ovary showed detectable levels of pS2 and there were not differences in cytosolic content between benign and malignant ovarian tumors. The pS2 levels were only associated to mucinous differentiation in both benign and malignant ovarian tumors (p=0.029 and p=0.015, respectively). Significantly higher

  1. Pressure measurements in the AGS Booster ultra-high vacuum system

    International Nuclear Information System (INIS)

    Gabusi, J.; Geller, J.; Hseuh, H.C.; Mapes, M.; Stattel, P.

    1992-01-01

    An average pressure of mid 10 -11 Torr has been achieved and maintained in the AGS Booster ring vacuum system during its first year of operation. This ultra-high vacuum system is monitored through remote controlled Bayard-Alpert Gauges (BAGs). The characteristics of the pressure measurements with BAGs over the long cable lengths (up to 200 m) and under various accelerator operating conditions will be described. Two types of noise in the pressure readouts have been identified; the electromagnetic interference (EMI) associated with the acceleration cycles of the Booster and the environment noise associated with the temperature of the collector cables. The magnitude of the noise pickup depends on the routing of the collector cables and reaches the equivalent pressure of low 10 -9 Torr

  2. The new heart of the PS is beating strongly

    CERN Multimedia

    Corinne Pralavorio

    2011-01-01

    The PS has resumed operation with a brand new electrical power system called POPS; this enormous system comprising power electronics and capacitors is crucial because if it broke down practically no particles would be able to circulate at CERN. As soon as it started, POPS passed all the tests with flying colours and is now pulsing at full power.   The new PS power system is made up of 6 containers, each with 60 tonnes of capacitors and 8 power converters. The date 11/02/11 will always be remembered with affection by the engineers in the Electrical Power Converters Group. At 11:11 in the morning (no joke), the first beams powered by the new system began to circulate in the PS. The cutely-named POPS (POwer for PS) took over from the old rotating machine that had been working since 1968. From now on it will be POPS that supplies the PS main magnets with the electrical pulses needed to accelerate the beams for the LHC and all CERN's other facilities. The system is crucial as the PS is one of the lyn...

  3. LEADIR-PS: the path to a safe and economic SMR

    Energy Technology Data Exchange (ETDEWEB)

    Hart, R.S. [Nothern Nuclear Industries Inc., Cambridge, Ontario (Canada)

    2014-07-01

    Northern Nuclear Industries Incorporated (N{sup 2} I{sup 2}) is developing a family of Small Modular Reactors (SMRs) called LEADIR-PS, an acronym for LEAD-cooled Integral Reactor-Passively Safe. LEADIR-PS plants under development, focused on process heat applications and the energy demands of Canada, are the LEADIR-PS100 with an output of 100 MWth and LEADIR-PS300 with an output of 300 MWth. A plant consisting of six LEADIR-PS300 reactor modules serving a common turbine-generator, called the LEADIR-PS Six-Pack, is focused on serving areas with higher energy demands. LEADIR-PS integrates the inherent safety features of the Modular High Temperature Gas Reactor and molten lead coolant in an integral pool type reactor configuration. Molten lead coolant, which boils at 1750 {sup o}C,avoids the cost of a reactor pressure vessel and high pressure/high temperature reactor coolant systems, and the safety concerns regarding pressure vessel and large capacity reactor coolant system piping rupture and precludes evaporation of the coolant. Molten lead does not chemically react with air, water, or graphite. The Gen IV+ LEADIR-PS plants are inherently/passively safe. There are no active systems required for safe shutdown and decay heat removal. Safety is assured without active or stored energy power supply, without a requirement to reposition valves or other devices and operator intervention or action. The unprecedented safety achieved by LEADIR-PS reactors avoids requirements for a large exclusion radius and demanding evacuation plan requirements. LEADIR-PS, with steam conditions of 370 {sup o}C and 12 MPa (more than twice that of water cooled reactors), can serve over 85% of the world's non-transportation process heat demands and is ideally suited to serving Combined Heat and Electricity demands and industrial parks. Energy utilization of over 95% is feasible in process heat and Combined Heat and Electricity applications. The simple robust design of LEADIR-PS plants in

  4. Pressure Monitoring Using Hybrid fs/ps Rotational CARS

    Science.gov (United States)

    Kearney, Sean P.; Danehy, Paul M.

    2015-01-01

    We investigate the feasibility of gas-phase pressure measurements at kHz-rates using fs/ps rotational CARS. Femtosecond pump and Stokes pulses impulsively prepare a rotational Raman coherence, which is then probed by a high-energy 6-ps pulse introduced at a time delay from the Raman preparation. Rotational CARS spectra were recorded in N2 contained in a room-temperature gas cell for pressures from 0.1 to 3 atm and probe delays ranging from 10-330 ps. Using published self-broadened collisional linewidth data for N2, both the spectrally integrated coherence decay rate and the spectrally resolved decay were investigated as means for detecting pressure. Shot-averaged and single-laser-shot spectra were interrogated for pressure and the accuracy and precision as a function of probe delay and cell pressure are discussed. Single-shot measurement accuracies were within 0.1 to 6.5% when compared to a transducer values, while the precision was generally between 1% and 6% of measured pressure for probe delays of 200 ps or more, and better than 2% as the delay approached 300 ps. A byproduct of the pressure measurement is an independent but simultaneous measurement of the gas temperature.

  5. Response of booster dose of cuban recombinant hepatitis-B vaccine in nonresponder and hyporesponder children

    International Nuclear Information System (INIS)

    Dahifar, H.; Mousavi, F.; Ghorbani, A.

    2007-01-01

    Acute hepatitis B infection can debilitate a patient for weeks and occasionally has a fatal outcome, while chronic infection is a major threat to the individual. To assess response of nonresponder and hyporesponder children to booster dose of Cuban recombinant hepatitis B vaccine. An interventional, descriptive study has been conducted on children who had been immunized with Cuban recombinant Hepatitis B vaccine and their antibody titers were <10mIU/ml (nonresponder) and 10-100mIU/ml (hyporesponder) administered booster dose of the same vaccine in their Deltoid muscles. The response of 141 children with the mean age of 1.9 years to booster dose of vaccine were 94.3% and 100% vaccines with the first and second booster dose of vaccination respectively. The anti-HBs titer in nonresponders and hyporesponders were 468+-346 and 783+-346mIU/ml respectively with significant differences between two groups (P=0.001). This study demonstrate moderately increase antibody production in the majority of vaccines with single supplementary vaccine. (author)

  6. Beam aperture and emittance growth in the AGS-Booster

    International Nuclear Information System (INIS)

    Parsa, Z.

    1987-01-01

    The authors have developed analytical tools for calculating the variation of particle action, smear and emittance growth due to nonlinear elements in accelerators (with second order perturbation theory in two dimensions). The authors' results for the AGS-Booster is presented

  7. Simulation of the capture process in the Fermilab Booster

    International Nuclear Information System (INIS)

    Stahl, S.; Ankenbrandt, C.

    1987-01-01

    A progress report on efforts to understand and improve adiabatic capture in the Fermilab Booster by experiment and simulation is presented. In particular, a new Rf voltage program for capture which ameliorates transverse space-charge effects is described and simulated

  8. OPTIMAL SCHEDULING OF BOOSTER DISINFECTION IN WATER DISTRIBUTION SYSTEMS

    Science.gov (United States)

    Booster disinfection is the addition of disinfectant at locations distributed throughout a water distribution system. Such a strategy can reduce the mass of disinfectant required to maintain a detectable residual at points of consumption in the distribution system, which may lea...

  9. High-Dose Vitamin C Injection to Cancer Patients May Promote Thrombosis Through Procoagulant Activation of Erythrocytes.

    Science.gov (United States)

    Kim, Keunyoung; Bae, Ok-Nam; Koh, Sung-Hee; Kang, Seojin; Lim, Kyung-Min; Noh, Ji-Yoon; Shin, Sue; Kim, Inho; Chung, Jin-Ho

    2015-10-01

    Potential risk of high-dose vitamin C consumption is often ignored. Recently, gram-dose vitamin C is being intravenously injected for the treatment of cancer, which can expose circulating blood cells to extremely high concentrations of vitamin C. As well as platelets, red blood cells (RBCs) can actively participate in thrombosis through procoagulant activation. Here, we examined the procoagulant and prothrombotic risks associated with the intravenous injection of gram-dose vitamin C. Vitamin C (0.5-5 mM) increased procoagulant activity of freshly isolated human RBCs via the externalization of phosphatidylserine (PS) to outer cellular membrane and the formation of PS-bearing microvesicles. PS exposure was induced by the dysregulation of key enzymes for the maintenance of membrane phospholipid asymmetry, which was from vitamin C-induced oxidative stress, and resultant disruption of calcium and thiol homeostasis. Indeed, the intravenous injection of vitamin C (0.5-1.0 g/kg) in rats in vivo significantly increased thrombosis. Notably, the prothrombotic effects of vitamin C were more prominent in RBCs isolated from cancer patients, who are at increased risks of thrombotic events. Vitamin C-induced procoagulant and prothrombotic activation of RBCs, and increased thrombosis in vivo. RBCs from cancer patients exhibited increased sensitivity to the prothrombotic effects of vitamin C, reflecting that intravenous gram-dose vitamin C therapy needs to be carefully revisited. © The Author 2015. Published by Oxford University Press on behalf of the Society of Toxicology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  10. The OMERACT psoriatic arthritis magnetic resonance imaging scoring system (PsAMRIS): definitions of key pathologies, suggested MRI sequences, and preliminary scoring system for PsA Hands

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; McQueen, Fiona; Wiell, Charlotte

    2009-01-01

    This article describes a preliminary OMERACT psoriatic arthritis magnetic resonance image scoring system (PsAMRIS) for evaluation of inflammatory and destructive changes in PsA hands, which was developed by the international OMERACT MRI in inflammatory arthritis group. MRI definitions of important...... pathologies in peripheral PsA and suggestions concerning appropriate MRI sequences for use in PsA hands are also provided....

  11. Energy and expectation values of the PsH system

    International Nuclear Information System (INIS)

    Mitroy, J.

    2006-01-01

    Close to converged energies and expectation values for PsH are computed using a ground state wave function consisting of 1800 explicitly correlated gaussians. The best estimate of the Ps ∞ H energy was -0.789 196 740 hartree which is the lowest variational energy to date. The 2γ annihilation rate for Ps ∞ H was 2.471 78x10 9 s -1

  12. Pengaruh Tandem Booster TNT Terhadap Kecepatan Detonasi Campuran Bahan Peledak Tepung Kalium Klorat, Sulfur Dan Aluminium Sebagai Bahan Peldak High Explosive

    OpenAIRE

    Tarigan, Tarsim

    2010-01-01

    There are a research on velocity of detonation explosives from Improvised Bomb with potassium chlorate, sulfur and aluminum with a composition of 65:20:15% (weight / weight), 70 mesh, galvanized pipes and containers with some blasting mechanism, starts with an explosion that ignite by a improvise detonator, factory detonator without a booster, factory detonator with a tandem booster TNT, and TNT booster modifications by adding a layer of Pb plate and make a cavity between the main booster ch...

  13. LMFBR with booster pump in pumping loop

    International Nuclear Information System (INIS)

    Rubinstein, H.J.

    1975-01-01

    A loop coolant circulation system is described for a liquid metal fast breeder reactor (LMFBR) utilizing a low head, high specific speed booster pump in the hot leg of the coolant loop with the main pump located in the cold leg of the loop, thereby providing the advantages of operating the main pump in the hot leg with the reliability of cold leg pump operation

  14. Control of Fermilab Booster tunes

    International Nuclear Information System (INIS)

    Johnson, R.P; Meisner, K.; Sandberg, B.

    1977-01-01

    Control of the radial and vertical tunes of the booster is implemented using ramped correction quadrupoles. Minor modifications to the power supply cards for the 48 (previously) dc correction quadrupoles allow ''the tunes'' to be continuously programmed or held constant throughout the 33 ms acceleration cycle. This capability is in addition to the usual use of these quadrupoles to be independently varied to correct for harmonic distortions in the lattice. An automatic computer program measures and displays the tunes vs. time in the cycle to monitor performance and to allow the ramps to be adjusted by the machine operator

  15. Emission properties of porphyrin compounds in new polymeric PS:CBP host

    Science.gov (United States)

    Jafari, Mohammad Reza; Bahrami, Bahram

    2015-06-01

    In this study, a device with fundamental structure of ITO/PEDOT:PSS (60 nm)/PS:CBP (70 nm)/Al (150 nm) was fabricated. The electroluminescence spectrum of device designated a red shift rather than PS:CBP photoluminescence spectra. It can be suggested that the electroplex emission occurs at PS:CBP interface. By following this step, red light-emitting devices using porphyrin compounds as a red dopant in a new host material PS:CBP with a configuration of ITO/PEDOT:PSS (60 nm)/PS:CBP:porphyrin compounds(70 nm)/Al (150 nm) have been fabricated and investigated. The electroluminescent spectra of the porphyrin compounds were red-shifted as compared with the PS:CBP blend. OLED devices based on doping 3,4PtTPP and TPPNO2 in PS:CBP showed purer red emission compared with ZnTPP and CoTPP doped devices. We believe that the electroluminescence performance of OLED devices based on porphyrin compounds depends on overlaps between the absorption of the porphyrin compounds and the emission of PS:CBP.

  16. Chemotherapy and quality of life in NSCLC PS 2 patients

    DEFF Research Database (Denmark)

    Helbekkmo, Nina; Strøm, Hans H; Sundstrøm, Stein H

    2009-01-01

    , fatigue, dyspnea, sleeping problems and appetite loss in comparison to the PS 0/1 group. CONCLUSIONS: PS 2 NSCLC patients seem to achieve valuable HRQOL benefits from platinum-based combination therapy. Prospective clinical studies with predefined HRQOL outcomes in PS 2 patients are needed to confirm...

  17. One-year post-primary antibody persistence and booster immune ...

    African Journals Online (AJOL)

    One-year post-primary antibody persistence and booster immune response to a DTaP-IPV//PRP~T vaccine (Pentaxim) given at 18 - 19 months of age in South African children primed at 6, 10 and 14 weeks of age with the same vaccine.

  18. PS overcomes two serious magnet failures

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    Two magnets and a bus bar connection in the PS were found to be faulty during high-voltage tests at the end of the accelerator shutdown. A five-week repair schedule was quickly devised. A team of mechanics, technicians and engineers worked at full speed to replace the faulty magnets, succeeding in limiting the delay of the accelerators' spring start-up to two weeks. These pictures show one of the magnets (no. 19) on the PS locomotive brought back into service for the removal and replacement operations.

  19. 47 CFR 90.219 - Use of signal boosters.

    Science.gov (United States)

    2010-10-01

    ... to operate radio systems in the frequency bands above 150 MHz may employ signal boosters at fixed... fill in only weak signal areas and cannot extend the system's normal signal coverage area. (b) Class A... effective radiated power (ERP) of the unit to a maximum of 5 watts under all conditions. Class B broadband...

  20. Beyond iPS!

    Directory of Open Access Journals (Sweden)

    Editorial

    2012-01-01

    Full Text Available It’s undoubtedly a jubilant moment for scientists and clinicians working in the stem cell arena as Prof. Gurdon and Prof. Shinya Yamanaka have been chosen for the Nobel Prize in Physiology & Medicine this year. The mystery of cell biology is something unfathomable and probably the work of this duo as well as the other scientists, who have put their hands on in- vitro de-differentiation have opened our eyes to a new window or a new paradigm in cell biology. The iPS invention has brought a lot of hope in terms of potential direct benefits to treat several diseases, which have no definite options at the moment. But, we envisage that several spin-offs could come out of this invention and one very significant spin-off finding recently witnessed is the finding by Prof. Masaharu Seno and his team of researchers at the Okayama University, Japan (Chen L, et al. 2012, PLoS ONE 7(4:e33544.doi:10.1371/journal.pone.0033544. According to Prof. Seno, mouse iPS cells (miPS when cultured in the conditioned medium derived from cancer cell lines, differentiate into cancer stem cells (CSCs. While differentiating into CSCs, they do retain the potential to develop endothelial progenitor cells. Several questions arise here: 1.Are these miPS derived CSCs really pluripotent, even if the terminal differentiation destined to specific phenotypes? 2.Shouldn’t the Cancer Stem Cells be termed as cancer progenitor cells, as till date they are considered to be producing only cancer cells but not pluripotent to yield other types of normal tissues? The spin-offs could be infinite as the process of differentiation and de-differentiation happening due to trillions of signals and pathways, most still remaining not-so-well understood. A special mention should be made to Prof. Shinya Yamanaka as he has several sterling qualities to be a role-model for budding scientists. Apart from his passion for science, which made him shift his career from orthopedics to a cell biologist, his

  1. PS auxiliary magnet

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    Units of the PS auxiliary magnet system. The picture shows how the new dipoles, used for vertical and horizontal high-energy beam manipulation, are split for installation and removal so that it is not necessary to break the accelerator vacuum. On the right, adjacent to the sector valve and the windings of the main magnet, is an octupole of the set.

  2. Simulation of the capture process in the Fermilab Booster

    International Nuclear Information System (INIS)

    Stahl, S.; Ankenbrandt, C.

    1987-09-01

    A progress report on efforts to understand and improve adiabatic capture in the Fermilab Booster by experiment and simulation is presented. In particular, a new RF voltage program for capture which ameliorates transverse space-charge effects is described and simulated. 7 refs., 4 figs

  3. Chromatic perturbation and resonance analysis for the AGS-Booster

    International Nuclear Information System (INIS)

    Parsa, Z.

    1987-01-01

    The authors investigated the nonlinear effects with the emphasis on nonlinear resonances. They present some of their findings, (e.g. the structure resonances; stop-bandwidths, etc.) for the AGS-Booster Lattice using program HARMON. Comparison with the results obtained from the algorithm ''NONLIN'' is presented

  4. Analysis of magnetic field measurement results for the AGS Booster magnets

    International Nuclear Information System (INIS)

    Bleser, E.; Thern, R.

    1991-01-01

    Magnetic field measurements have been made on nearly 200 conventional magnets that have been installed in the AGS Booster and its associated transfer lines. The measurements were intended to monitor the quality of the magnets being produced and to check the performance of each magnet before installation. The magnetic measurements effort led to certain improvements in the manufacturing process, which ten subsequently produced very good, very uniform magnets. The integrated dipole fields of the 36 booster dipoles are uniform to 1.5 parts in ten thousand. The magnetic measurements indicate that the quadrupoles were manufactured to an accuracy of 3 ten thousandths of an inch, which is better than we can physically measure. 3 refs., 2 figs., 4 tabs

  5. Caracterização viscosimétrica de nanocompósitos híbridos PS/POSS Viscometric characterization of PS/POSS hybrid nanocomposites

    Directory of Open Access Journals (Sweden)

    Otávio Bianchi

    2012-01-01

    Full Text Available Nanocompósitos híbridos de poliestireno (PS e poliedros oligoméricos silsesquioxanos (POSS com diferentes composições e graus de hibridização foram obtidos por processamento reativo no estado fundido utilizando-se peróxido de dicumila (DCP como iniciador, na presença ou não de estireno como agente de transferência de radical. Os materiais foram caracterizados viscosimetricamente por cromatografia de permeação em gel (GPC usando detecção tripla por espalhamento de luz, viscosimetria e índice de refração. As amostras PS/POSS processadas com estireno apresentaram maiores valores de massa molar ponderal média (Mw e menores valores de polidispersão (Mw/Mn, devido ao maior grau de conversão da reação de hibridização do PS-POSS (28-40% e do menor grau de degradação (cisão das cadeias do PS, quando comparadas com amostras PS/POSS processadas sem estireno nas quais o grau de conversão ficou em torno de 24-28%. Para os sistemas PS e PS/POSS em solução com THF, os parâmetros da equação de Mark-Houwink-Sakurada (MHS, α ≅ 0,7 e log K ≅ -3,5 a -3,9 e os valores dos parâmetros de interação polímero-solvente, χij ≅ 0,49, não apresentaram diferenças significativas com relação aos tamanhos moleculares. Por outro lado, essas diferenças de tamanhos moleculares foram caracterizadas por uma função cumulativa da fração mássica de cadeias em função da distância média quadrática entre pontas de cadeia (0½.Polystyrene (PS and polyhedral oligomeric silsesquioxanes (POSS hybrid nanocomposites with different compositions were obtained by reactive melt processing using dicumyl peroxide (DCP as initiator in the presence or absence of styrene as radical transfer agent. The materials were characterized by viscosimetry by means of gel permeation chromatography (GPC using triple-detector: light scattering, viscometer and refractive index. PS/POSS samples processed with styrene showed higher weight average molecular

  6. 47 CFR 101.151 - Use of signal boosters.

    Science.gov (United States)

    2010-10-01

    ... authorized to operate multiple address systems in the 928-929/952-960 MHz and 932-932.5/941-941.5 MHz bands..., or portable station(s). The booster will fill in only weak signal areas and cannot extend the system... automatic gain control circuitry which will limit the total effective radiated power (ERP) of the unit to a...

  7. Exact PsTd invariant and PsTd symmetric breaking solutions, symmetry reductions and Bäcklund transformations for an AB-KdV system

    Science.gov (United States)

    Jia, Man; Lou, Sen Yue

    2018-05-01

    In natural and social science, many events happened at different space-times may be closely correlated. Two events, A (Alice) and B (Bob) are defined as correlated if one event is determined by another, say, B = f ˆ A for suitable f ˆ operators. A nonlocal AB-KdV system with shifted-parity (Ps, parity with a shift), delayed time reversal (Td, time reversal with a delay) symmetry where B =Ps ˆ Td ˆ A is constructed directly from the normal KdV equation to describe two-area physical event. The exact solutions of the AB-KdV system, including PsTd invariant and PsTd symmetric breaking solutions are shown by different methods. The PsTd invariant solution show that the event happened at A will happen also at B. These solutions, such as single soliton solutions, infinitely many singular soliton solutions, soliton-cnoidal wave interaction solutions, and symmetry reduction solutions etc., show the AB-KdV system possesses rich structures. Also, a special Bäcklund transformation related to residual symmetry is presented via the localization of the residual symmetry to find interaction solutions between the solitons and other types of the AB-KdV system.

  8. LHC Report: The shutdown work nearing completion

    CERN Multimedia

    CERN Bulletin

    2011-01-01

    The work planned for the LHC injector chain during the winter shutdown is nearing completion. The PS Booster (PSB) and PS will be closed to access next week, and the control of machine access will be transferred to the CERN Control Centre in preparation for the resumption of machine operation. Hardware tests are being performed in all the machines.   Tests are under way in the LHC tunnel. The technical teams are putting the finishing touches to the work planned for the winter shutdown. At the Linac2, the PS Booster and the PS, work will be completed next week and hardware tests will be carried out soon after. POPS, the new powering system for the PS, will be commissioned for the first time in the coming days after the necessary preliminary tests have been carried out. At the SPS, various magnets have been replaced over recent weeks and the performance tests on the main power supply and other hardware tests will be able to start shortly. After that, the machine will be ready for operation with b...

  9. Hepatitis B virus vaccination booster does not provide additional protection in adolescents: a cross-sectional school-based study.

    Science.gov (United States)

    Chang, Yung-Chieh; Wang, Jen-Hung; Chen, Yu-Sheng; Lin, Jun-Song; Cheng, Ching-Feng; Chu, Chia-Hsiang

    2014-09-23

    Current consensus does not support the use of a universal booster of hepatitis B virus (HBV) vaccine because there is an anamnestic response in almost all children 15 years after universal infant HBV vaccination. We aimed to provide a booster strategy among adolescents as a result of their changes in lifestyle and sexual activity. This study comprised a series of cross-sectional serological surveys of HBV markers in four age groups between 2004 and 2012. The seropositivity rates of hepatitis B surface antigen (HBsAg) and its reciprocal antibody (anti-HBs) for each age group were collected. There were two parts to this study; age-specific HBV seroepidemiology and subgroup analysis, including effects of different vaccine types, booster response for immunogenicity at 15 years of age, and longitudinal follow-up to identify possible additional protection by HBV booster. Within the study period, data on serum anti-HBs and HBsAg in a total of 6950 students from four age groups were collected. The overall anti-HBs and HBsAg seropositivity rates were 44.3% and 1.2%, respectively. The anti-HBs seropositivity rate in the plasma-derived subgroup was significantly higher in both 15- and 18-year age groups. Overall response rate in the double-seronegative recipients at 15 years of age was 92.5% at 6 weeks following one recombinant HBV booster dose. Among the 24 recipients showing anti-HBs seroconversion at 6 weeks after booster, seven subjects (29.2%) had lost their anti-HBs seropositivity again within 3 years. Increased seropositivity rates and titers of anti-HBs did not provide additional protective effects among subjects comprehensively vaccinated against HBV in infancy. HBV booster strategy at 15 years of age was the main contributor to the unique age-related phenomenon of anti-HBs seropositivity rate and titer. No increase in HBsAg seropositivity rates within different age groups was observed. Vaccination with plasma-derived HBV vaccines in infancy provided higher

  10. PS-Modules over Ore Extensions and Skew Generalized Power Series Rings

    Directory of Open Access Journals (Sweden)

    Refaat M. Salem

    2015-01-01

    Full Text Available A right R-module MR is called a PS-module if its socle, SocMR, is projective. We investigate PS-modules over Ore extension and skew generalized power series extension. Let R be an associative ring with identity, MR a unitary right R-module, O=Rx;α,δ Ore extension, MxO a right O-module, S,≤ a strictly ordered additive monoid, ω:S→EndR a monoid homomorphism, A=RS,≤,ω the skew generalized power series ring, and BA=MS,≤RS,≤, ω the skew generalized power series module. Then, under some certain conditions, we prove the following: (1 If MR is a right PS-module, then MxO is a right PS-module. (2 If MR is a right PS-module, then BA is a right PS-module.

  11. Proceedings of the workshop on the PS-spin collider

    International Nuclear Information System (INIS)

    Mori, Yoshiharu

    1993-05-01

    This volume is a record of the PS-Spin Collider Workshop which was held at KEK, Jan. 31-Feb.1, 1992. As a future project of the KEK 12-GeV proton synchrotron (KEK-PS), the hadron collider (PS-Collider), has been under discussion. Originally, the PSC was designed for heavy ion beam collisions with the energy range of 5-7 GeV/u. If polarized protons are accelerated in PSC, 19 x 19 GeV collisions are possible. This workshop was proposed to bring together interested experimentalists and accelerator physicists to discuss the case that could be made for polarization physics and the technical feasibility at the PS Spin Collider. More than 30 physicists participated in the workshop and very interesting and useful discussions took place. (author)

  12. Effectiveness of Humidification with Heat and Moisture Exchanger-booster in Tracheostomized Patients.

    Science.gov (United States)

    Gonzalez, Isabel; Jimenez, Pilar; Valdivia, Jorge; Esquinas, Antonio

    2017-08-01

    The two most commonly used types of humidifiers are heated humidifiers and heat and moisture exchange humidifiers. Heated humidifiers provide adequate temperature and humidity without affecting the respiratory pattern, but overdose can cause high temperatures and humidity resulting in condensation, which increases the risk of bacteria in the circuit. These devices are expensive. Heat and moisture exchanger filter is a new concept of humidification, increasing the moisture content in inspired gases. This study aims to determine the effectiveness of the heat and moisture exchanger (HME)-Booster system to humidify inspired air in patients under mechanical ventilation. We evaluated the humidification provided by 10 HME-Booster for tracheostomized patients under mechanical ventilation using Servo I respirators, belonging to the Maquet company and Evita 4. There was an increase in the inspired air humidity after 1 h with the humidifier. The HME-Booster combines the advantages of heat and moisture exchange minimizing the negatives. It increases the amount of moisture in inspired gas in mechanically ventilated tracheostomized patients. It is easy and safe to use. The type of ventilator used has no influence on the result.

  13. Modeling of the YALINA booster facility by the Monte Carlo code MONK

    International Nuclear Information System (INIS)

    Talamo, A.; Gohar, Y.; Kondev, F.; Kiyavitskaya, H.; Serafimovich, I.; Bournos, V.; Fokov, Y.; Routkovskaya, C.

    2007-01-01

    The YALINA-Booster facility has been modeled according to the benchmark specifications defined for the IAEA activity without any geometrical homogenization using the Monte Carlo codes MONK and MCNP/MCNPX/MCB. The MONK model perfectly matches the MCNP one. The computational analyses have been extended through the MCB code, which is an extension of the MCNP code with burnup capability because of its additional feature for analyzing source driven multiplying assemblies. The main neutronics arameters of the YALINA-Booster facility were calculated using these computer codes with different nuclear data libraries based on ENDF/B-VI-0, -6, JEF-2.2, and JEF-3.1.

  14. Simulation of a programmed frequency shift near extraction from the Fermilab Booster

    International Nuclear Information System (INIS)

    Lucas, P.; Kerns, Q.

    1987-03-01

    The longitudinal phase space program ESME has been used to simulate the effects of a linear shift in RF frequency away from that appropriate for the accelerator guide field. This shift takes place in the new Booster low level RF and is used to position the particle bunches in Main Ring buckets in a reproducible fashion. Shifts in frequency are found to generate synchrotron oscillations; however, the simulations show that these can be reduced to acceptable levels by introduction of jumps in RF phase preceding the programmed frequency changes. Lowering the RF voltage near extraction from the Booster, a desirable operational feature, has also been investigated

  15. Ultrafast spin injection from Cd1-x Mn x Te magnetic barriers into a CdTe quantum well studied by pump-probe spectroscopy

    International Nuclear Information System (INIS)

    Aoshima, I.; Nishibayashi, K.; Souma, I.; Murayama, A.; Oka, Y.

    2006-01-01

    Spin injection from diluted magnetic semiconductor (DMS) barriers of Cd 1- x Mn x Te into a quantum well (QW) of CdTe is studied, by means of pump-probe absorption spectroscopy in magnetic fields. Fast decay characteristics of circularly polarized differential absorbances of spin-polarized excitons in the DMS barrier show the exciton injection time of 6 ps from the barriers into the QW. In accordance with the fast relaxation of the spin-polarized excitons from the barrier, we observe the rise of circular polarization degree for the differential absorption of the CdTe QW in magnetic fields, evidently indicating the spin injection. In addition, the circular polarization degree up to 0.3 is developed in the well immediately after pumping, originating from the fast relaxation of a heavy hole (hh) spin less than 0.2 ps, due to the giant Zeeman effect caused by the penetration of the hh wave function into the DMS barriers

  16. Eddy current septum magnets for injection and extraction at SSRF

    International Nuclear Information System (INIS)

    Ouyang Lianhua; Gu Ming; Liu Bo; Chen Rong

    2010-01-01

    There are 6 in-vacuum eddy current septum magnets used for booster injection, extraction, and storage ring injection in SSRF. Special attention was paid to coils and their support designs because of the shock force they bear in the magnetic fields and the high heat which is hard to be dissipated in vacuum environment. For the storage ring magnets, good transverse homogeneity in the gap was achieved by careful design, precise machining and accurate assembly; and an extremely low leakage field on the stored beam is another key feature thanks to the high permeability Mu metal. Magnetic field measurement was conducted with both a point coil and a long integral coil, and the results agree well with the OPERA-2d/3d simulations. An inner tube is added to keep the continuity of impedance for the circulating beam with two RF finger flanges at each end. There is no vacuum separation between the inner tube and the magnet chamber. Sputter ion pumps integrated with NEG are used to acquire the UHV for the chamber. (authors)

  17. Emergency department transport rates of children from the scene of motor vehicle collisions: do booster seats make a difference?

    Science.gov (United States)

    House, Darlene R; Huffman, Gretchen; Walthall, Jennifer D H

    2012-11-01

    Motor vehicle collisions (MVCs) are the leading cause of death and disability among children older than 1 year. Many states currently mandate all children between the ages of 4 and 8 years be restrained in booster seats. The implementation of a booster-seat law is generally thought to decrease the occurrence of injury to children. We hypothesized that appropriate restraint with booster seats would also cause a decrease in emergency department (ED) visits compared with children who were unrestrained. This is an important measure as ED visits are a surrogate marker for injury. The main purpose of this study was to look at the rate of ED visits between children in booster seats compared with those in other or no restraint systems involved in MVCs. Injury severity was compared across restraint types as a secondary outcome of booster-seat use after the implementation of a state law. A prospective observational study was performed including all children 4 to 8 years old involved in MVCs to which emergency medical services was dispatched. Ambulance services used a novel on-scene computer charting system for all MVC-related encounters to collect age, sex, child-restraint system, Glasgow Coma Scale score, injuries, and final disposition. One hundred fifty-nine children were studied with 58 children (35.6%) in booster seats, 73 children in seatbelts alone (45.2%), and 28 children (19.1%) in no restraint system. 76 children (47.7%), 74 by emergency medical services and 2 by private vehicle, were transported to the ED with no significant difference between restraint use (P = 0.534). Utilization of a restraint system did not significantly impact MVC injury severity. However, of those children who either died (n = 2) or had an on-scene decreased Glasgow Coma Scale score (n = 6), 75% (6/8) were not restrained in a booster seat. The use of booster-seat restraints does not appear to be associated with whether a child will be transported to the ED for trauma evaluation.

  18. Standardized error severity score (ESS) ratings to quantify risk associated with child restraint system (CRS) and booster seat misuse.

    Science.gov (United States)

    Rudin-Brown, Christina M; Kramer, Chelsea; Langerak, Robin; Scipione, Andrea; Kelsey, Shelley

    2017-11-17

    Although numerous research studies have reported high levels of error and misuse of child restraint systems (CRS) and booster seats in experimental and real-world scenarios, conclusions are limited because they provide little information regarding which installation issues pose the highest risk and thus should be targeted for change. Beneficial to legislating bodies and researchers alike would be a standardized, globally relevant assessment of the potential injury risk associated with more common forms of CRS and booster seat misuse, which could be applied with observed error frequency-for example, in car seat clinics or during prototype user testing-to better identify and characterize the installation issues of greatest risk to safety. A group of 8 leading world experts in CRS and injury biomechanics, who were members of an international child safety project, estimated the potential injury severity associated with common forms of CRS and booster seat misuse. These injury risk error severity score (ESS) ratings were compiled and compared to scores from previous research that had used a similar procedure but with fewer respondents. To illustrate their application, and as part of a larger study examining CRS and booster seat labeling requirements, the new standardized ESS ratings were applied to objective installation performance data from 26 adult participants who installed a convertible (rear- vs. forward-facing) CRS and booster seat in a vehicle, and a child test dummy in the CRS and booster seat, using labels that only just met minimal regulatory requirements. The outcome measure, the risk priority number (RPN), represented the composite scores of injury risk and observed installation error frequency. Variability within the sample of ESS ratings in the present study was smaller than that generated in previous studies, indicating better agreement among experts on what constituted injury risk. Application of the new standardized ESS ratings to installation

  19. Immunogenicity and safety of combined adsorbed low-dose diphtheria, tetanus and inactivated poliovirus vaccine (REVAXIS®) versus combined diphtheria, tetanus and inactivated poliovirus vaccine (DT Polio®) given as a booster dose at 6 years of age

    Science.gov (United States)

    Gajdos, Vincent; Soubeyrand, Benoit; Vidor, Emmanuel; Richard, Patrick; Boyer, Julie; Sadorge, Christine

    2011-01-01

    This randomized, comparative, phase-IIIb study conducted in France aimed to demonstrate whether seroprotection against diphtheria, tetanus and poliomyelitis 1 month after a single dose of REVAXIS (low-dose diphtheria) is non-inferior to seroprotection 1 month after a single dose of DT Polio (standard-dose diphtheria), both vaccines being given as a second booster to healthy children at 6 years of age. Children were randomly assigned to receive a single intramuscular dose of REVAXIS or DT Polio. Primary endpoints were the 1-month post-booster seroprotection rates for diphtheria, tetanus and poliovirus type-1, -2 and -3 antigens. Secondary endpoints were immunogenicity and safety observations. Of 788 children screened, 760 were randomized: REVAXIS group, 384 children; DT Polio group, 376 children. No relevant difference in demographic characteristics at baseline was observed between REVAXIS and DT Polio groups. Noninferiority of REVAXIS compared with DT Polio for seroprotection was demonstrated against diphtheria (respectively 98.6% and 99.3%), tetanus (respectively 99.6% and 100%) and poliovirus antigens (100% for each types in both groups). No allergic reactions to REVAXIS were reported. A benefit/risk ratio in favor of REVAXIS was suggested by the trend towards a better tolerability of REVAXIS compared with DT Polio regarding the rate of severe solicited injection-site reactions. The results support the use of REVAXIS as a booster at 6 years of age in infants who previously received a three-dose primary series within the first 6 months of life and a first booster including diphtheria, tetanus and poliovirus vaccine(s) given before 2 years of age. PMID:21441781

  20. Pertussis circulation has increased T-cell immunity during childhood more than a second acellular booster vaccination in Dutch children 9 years of age.

    Directory of Open Access Journals (Sweden)

    Rose-Minke Schure

    Full Text Available UNLABELLED: Here we report the first evaluation of T-cell responses upon a second acellular pertussis booster vaccination in Dutch children at 9 years of age, 5 years after a preschool booster vaccination. Blood samples of children 9 years of age were studied longitudinally until 1 year after the second aP booster and compared with those after the first aP booster in children 4 and 6 years of age from a cross-sectional study. After stimulation with pertussis-vaccine antigens, Th1, Th2 and Th17 cytokine responses were measured and effector memory cells (CCR7-CD45RA- were characterized by 8-colour FACS analysis. The second aP booster vaccination at pre-adolescent age in wP primed individuals did increase pertussis-specific Th1 and Th2 cytokine responses. Noticeably, almost all T-cell responses had increased with age and were already high before the booster vaccination at 9 years of age. The enhancement of T-cell immunity during the 5 year following the booster at 4 years of age is probably caused by natural boosting due to the a high circulation of pertussis. However, the incidence of pertussis is high in adolescents and adults who have only received the Dutch wP vaccine during infancy and no booster at 4 years of age. Therefore, an aP booster vaccination at adolescence or later in these populations might improve long-term immunity against pertussis and reduce the transmission to the vulnerable newborns. TRIAL REGISTRATION: Controlled-Trials.com ISRCTN64117538.

  1. Omega-conotoxin- and nifedipine-insensitive voltage-operated calcium channels mediate K(+)-induced release of pro-thyrotropin-releasing hormone-connecting peptides Ps4 and Ps5 from perifused rat hypothalamic slices.

    Science.gov (United States)

    Valentijn, K; Tranchand Bunel, D; Vaudry, H

    1992-07-01

    The rat thyrotropin-releasing hormone (TRH) precursor (prepro-TRH) contains five copies of the TRH progenitor sequence linked together by intervening sequences. Recently, we have shown that the connecting peptides prepro-TRH-(160-169) (Ps4) and prepro-TRH-(178-199) (Ps5) are released from rat hypothalamic neurones in response to elevated potassium concentrations, in a calcium-dependent manner. In the present study, the role of voltage-operated calcium channels in potassium-induced release of Ps4 and Ps5 was investigated, using a perifusion system for rat hypothalamic slices. The release of Ps4 and Ps5 stimulated by potassium (70 mM) was blocked by the inorganic ions Co2+ (2.6 mM) and Ni2+ (5 mM). In contrast, the stimulatory effect of KCl was insensitive to Cd2+ (100 microM). The dihydropyridine antagonist nifedipine (10 microM) had no effect on K(+)-evoked release of Ps4 and Ps5. Furthermore, the response to KCl was not affected by nifedipine (10 microM) in combination with diltiazem (1 microM), a benzothiazepine which increases the affinity of dihydropyridine antagonists for their receptor. The dihydropyridine agonist BAY K 8644, at concentrations as high as 1 mM, did not stimulate the basal secretion of Ps4 and Ps5. In addition, BAY K 8644 had no potentiating effect on K(+)-induced release of Ps4 and Ps5. The marine cone snail toxin omega-conotoxin, a blocker of both L- and N-type calcium channels had no effect on the release of Ps4 and Ps5 stimulated by potassium. Similarly, the omega-conopeptide SNX-111, a selective blocker of N-type calcium channels, did not inhibit the stimulatory effect of potassium. The release of Ps4 and Ps5 evoked by high K+ was insensitive to the non-selective calcium channel blocker verapamil (20 microM). Amiloride (1 microM), a putative blocker of T-type calcium channels, did not affect KCl-induced secretion of the two connecting peptides. Taken together, these results indicate that two connecting peptides derived from the pro-TRH, Ps

  2. Results from the AGS Booster transverse damper

    International Nuclear Information System (INIS)

    Russo, D.; Brennan, M.; Meth, M.; Roser, T.

    1993-01-01

    To reach the design intensity of 1.5 x 10 13 protons per pulse in the AGS Booster, transverse coupled bunch instabilities with an estimated growth rate of 1500s -1 have to be dampened. A prototype transverse damper has been tested successfully using a one turn digital delay and closed orbit suppression implemented in a programmable gate array. An updated damper, which includes an algorithm to optimize damping for a changing betatron rune, will also be presented

  3. First experience with carbon stripping foils for the 160 MeV H- injection into the CERN PSB

    Science.gov (United States)

    Weterings, Wim; Bracco, Chiara; Jorat, Louise; Noulibos, Remy; van Trappen, Pieter

    2018-05-01

    160 MeV H- beam will be delivered from the new CERN linear accelerator (Linac4) to the Proton Synchrotron Booster (PSB), using a H- charge-exchange injection system. A 200 µg/cm2 carbon stripping foil will convert H- into protons by stripping off the electrons. The H- charge-exchange injection principle will be used for the first time in the CERN accelerator complex and involves many challenges. In order to gain experience with the foil changing mechanism and the very fragile foils, in 2016, prior to the installation in the PSB, a stripping foil test stand has been installed in the Linac4 transfer line. In addition, parts of the future PSB injection equipment are also temporarily installed in the Linac4 transfer line for tests with a 160 MeV H- commissioning proton beam. This paper describes the foil changing mechanism and control system, summarizes the practical experience of gluing and handling these foils and reports on the first results with beam.

  4. Booster HBV vaccination; is it really necessary? | Alavian | Egyptian ...

    African Journals Online (AJOL)

    Egyptian Journal of Pediatric Allergy and Immunology (The). Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 9, No 2 (2011) >. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register. Booster HBV vaccination; is it ...

  5. Power Supply of the Booster Magnets for the ILSF Synchrotron

    Directory of Open Access Journals (Sweden)

    O Ahmadi

    2017-08-01

    Full Text Available The Iranian Light Source Facility (ILSF booster main specifications including 250 ms ramp up, 2Hz repetition rate, and quasi-sinusoidal wave shape, up to this point have been the basis for calculations. Each family of magnets including Dipole, Quadrupole and Sextupoles will feed by individual power supply. In order to maintain constant transverse tunes and chromaticity while the beam is accelerated, quadrupole and sextupole magnet currents must closely track the current in the dipole magnets. In booster rings, feeding the high inductance load, tracking of Quadrupole and sextupole magnets, reducing output current fluctuation and having a precise high bandwidth current regulation system are particular challenges. In order to meet the requirements, it is necessary to have a fully digital controller to achieve a fast regulation system. The prototype power supply and its test results are described in this paper  

  6. The AGS Booster vacuum systems

    International Nuclear Information System (INIS)

    Hseuh, H.C.

    1989-01-01

    The AGS Booster is a synchrotron for the acceleration of both protons and heavy ions. The design pressure of low 10 -11 mbar is required to minimize beam loss of the partially stripped heavy ions. To remove contaminants and to reduce outgassing, the vacuum chambers and the components located in them will be chemically cleaned, vacuum fired, baked then treated with nitric oxide. The vacuum sector will be insitu baked to a minimum of 200 degree C and pumped by the combination of sputter ion pumps and titanium sublimation pumps. This paper describes the design and the processing of this ultra high vacuum system, and the performance of some half-cell vacuum chambers. 9 refs., 7 figs

  7. REDUCING THE BOOSTER STATIONS ENERGY CONSUMPTION BY WAY OF ELIMINATING OVERPRESSURE IN THE WATER SUPPLY NETWORK

    Directory of Open Access Journals (Sweden)

    G. N. Zdor

    2015-01-01

    Full Text Available The energy efficiency improvement of the city housing-and-utilities infrastructure and watersupply and water-disposal systems poses an occurrent problem. The water-supply systems energy consumption sizable share falls on the pump plants. The article deals with the issues of the operating regime management of the existing booster stations equipped with a group of pumping units regulated with frequency converters. One of the optimization directions of their energy consumption is the reduction of over-pressure in the water-distribution network and its sustentation within the regulatory values. The authors offer the structure and methodology of the data collection-and-analysis automated system utilization for revealing and eliminating the overpressure in the water-supply network. This system is designed for the group management of booster-stations operating regimes on the ground of data obtained from the pressure controlling devices at the consumers. The data exchange in the system is realized via GSM.The paper presents results of the tests carried out at the booster stations in some major cities of the Republic of Belarus. The authors analyze dependence of overpressure in the network on the methods of the plant output pressure sustentation (daily graph or constant pressure. The authors study the elimination effect of over-pressure in the water distribution network on changing the booster station pumping units operation regimes. The study shows that eliminating over pressure in the water distributing network leads to lowering the booster station pressure. This in its turn decreases its energy consumption by 15–20 % depending on the over pressure fixed level.

  8. Beam position monitoring in the AGS Linac to Booster transfer line

    International Nuclear Information System (INIS)

    Shea, T.J.; Brodowski, J.; Witkover, R.

    1991-01-01

    A beam position monitor system has been developed and used in the commissioning of Brookhaven's Linac to Booster transfer line. This line transports a chopped, RF modulated H- beam from the 200 MeV Linac to the AGS Booster. Over a 15dB dynamic range in beam current, the position monitor system provides a real-time, normalized position signal with an analog bandwidth of about 20 MHz. Seven directional coupler style pickups are installed in the line with each pickup sensing both horizontal and vertical position. Analog processing electronics are located in the tunnel and incorporate the amplitude modulation to phase modulation normalization technique. To avoid interference from the 200 MHz linac RF system, processing is performed at 400 MHz. This paper provides a system overview and report results from the commissioning experience

  9. Development of hydraulic brake actuator for active brake control; Active brake seigyoyo yuatsu booster no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Konishi, Y; Hattori, M. Sugisawa, M.; Nishii, M [Aisin Seiki Co. Ltd., Aichi (Japan)

    1997-10-01

    Recently, application of active brake control systems of the vehicle are increasing. (Vehicle stability control, Panic brake assist ) We have developed a new hydraulic brake actuator for active brake control systems. New hydraulic brake actuator is composed of the three parts. (Hydraulic booster unit, Power supply unit, Control valve unit) This report describes the construction of the new hydraulic booster unit. 2 refs., 10 figs.

  10. Delay-line cables for the fast bumpers in the PS.

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    For 'continuous transfer' to the SPS, the beam accelerated in the PS is shaved off over several turns, so as to form a continuous sequence of bunches several times the length of the PS circumference. Fast bumpers, powered in a 'staircase' way, displace the PS beam stepwise towards the ejection septum. Each step lasts 2.1 microsec and the cable drums in this picture contain some of the bumper delay-lines of altogether 10 km.

  11. Exercise, Manual Therapy, and Booster Sessions in Knee Osteoarthritis: Cost-Effectiveness Analysis From a Multicenter Randomized Controlled Trial.

    Science.gov (United States)

    Bove, Allyn M; Smith, Kenneth J; Bise, Christopher G; Fritz, Julie M; Childs, John; Brennan, Gerard P; Abbott, J Haxby; Fitzgerald, G Kelley

    2018-01-01

    Limited information exists regarding the cost-effectiveness of rehabilitation strategies for individuals with knee osteoarthritis (OA). The study objective was to compare the cost-effectiveness of 4 different combinations of exercise, manual therapy, and booster sessions for individuals with knee OA. This economic evaluation involved a cost-effectiveness analysis performed alongside a multicenter randomized controlled trial. The study took place in Pittsburgh, Pennsylvania; Salt Lake City, Utah; and San Antonio, Texas. The study participants were 300 individuals taking part in a randomized controlled trial investigating various physical therapy strategies for knee OA. Participants were randomized into 4 treatment groups: exercise only (EX), exercise plus booster sessions (EX+B), exercise plus manual therapy (EX+MT), and exercise plus manual therapy and booster sessions (EX+MT+B). For the 2-year base case scenario, a Markov model was constructed using the United States societal perspective and a 3% discount rate for costs and quality-adjusted life years (QALYs). Incremental cost-effectiveness ratios were calculated to compare differences in cost per QALY gained among the 4 treatment strategies. In the 2-year analysis, booster strategies (EX+MT+B and EX+B) dominated no-booster strategies, with both lower health care costs and greater effectiveness. EX+MT+B had the lowest total health care costs. EX+B cost ${\\$}$1061 more and gained 0.082 more QALYs than EX+MT+B, for an incremental cost-effectiveness ratio of ${\\$}$12,900/QALY gained. The small number of total knee arthroplasty surgeries received by individuals in this study made the assessment of whether any particular strategy was more successful at delaying or preventing surgery in individuals with knee OA difficult. Spacing exercise-based physical therapy sessions over 12 months using periodic booster sessions was less costly and more effective over 2 years than strategies not containing booster sessions for

  12. Maintaining the potential of a psycho-educational program: efficacy of a booster session after an intervention offered family caregivers at disclosure of a relative's dementia diagnosis.

    Science.gov (United States)

    Ducharme, Francine; Lachance, Lise; Lévesque, Louise; Zarit, Steven Howard; Kergoat, Marie-Jeanne

    2015-01-01

    Booster sessions as a means of maintaining the benefits of psycho-educational programs have received little attention in caregiving research. Caregivers were offered a booster session following participation in a program entitled Learning to Become a Family Caregiver (LBFC) intended to facilitate transition to the caregiver role after diagnostic disclosure of dementia in a relative. The 90-minute booster session served to review program content and afforded the opportunity to discuss and practice learned skills. This study sought to test the efficacy of the booster session in maintaining or recovering program effects at six months post-program. Participants in the program were randomly assigned to a group that received the booster session (n = 31) or a group that did not (n = 29). A third control group was also formed, which continued to receive only the usual care provided in memory clinics. Eligible participants - French-speaking primary caregivers of a relative diagnosed with Alzheimer's in the past nine months - were recruited in memory clinics in Quebec (Canada). Participants were blindly assessed before randomization and six months after the booster session on outcomes associated with a healthy role transition. Prediction analyses revealed one significant positive effect of the booster session: emergence of preparedness to provide care. Moreover, with or without the booster session, the program continued to have a positive effect on psychological distress and contributed to the emergence of self-efficacy in dealing with caregiving situations. The booster session had no significant effect on knowledge of services, planning for future care needs, use of reframing as a coping strategy, perceived informal support, and family conflicts. The limited effect observed is discussed in terms of the booster session's content and intensity. Recommendations are made for designing future research on the effect of booster sessions, including the importance of including a

  13. Design and testing of the AGS Booster BPM detector

    International Nuclear Information System (INIS)

    Thomas, R.; Ciardullo, D.J.; Van Zwienen, W.

    1991-01-01

    The AGS Booster beam position monitor system must accurately measure the position of beams and bunches over a wide range of intensity. The frequency of operation must also cover a wide range (600 kHz to 4.2 MHz) since the Booster accelerates both protons and heavy ions. Split-cylinder electrodes were chosen to monitor the position of the beam because of their good low frequency response and high linearity. The need to accelerate low-energy partially-stripped heavy ions requires the pick-up electrodes (PUEs) to operate in a 3 x 10 -11 torr vacuum. The PUEs are to measure the beam position to an absolute accuracy of ±0.5 mm and must therefore be mechanically stable despite the requirements that they be vacuum fired at 950 degree C and baked periodically to 300 degree C. This presentation describes both the mechanical design of the PUEs and the automated test procedure used to ensure the stability, accuracy, and linearity of each unit. 3 refs., 5 figs

  14. Low Energy Electron Cooler for NICA Booster

    CERN Document Server

    Denisov, A P

    2017-01-01

    BINP has developed an electron cooler to increase the ion accumulation efficiency in the NICA (Nuclotron-based Ion Collider fAcility) heavy ion booster (JINR, Dubna). Adjustment of the cooler magnetic system provides highly homogeneous magnetic field in the cooling section B trans/B long ≤ 4∙10-5 which is vital for efficient electron cooling. First experiments with an electron beam performed at BINP demonstrated the target DC current of 500 mA and electron energy 6 keV.

  15. Differential expression of GSK3β and pS9GSK3β in normal human tissues: can pS9GSK3β be an epithelial marker?

    Science.gov (United States)

    Lee, Hojung; Ro, Jae Y

    2015-01-01

    Glycogen synthase kinase 3β (GSK3β) and phosphorylated GSK3β at Ser9 (pS9GSK3β) are crucial in cellular proliferation and metabolism. GSK3β and pS9GSK3β are deregulated in many diseases including tumors. Data on altered expression of GSK3β and pS9GSK3β are mainly limited to tumor tissues, thus the expression of GSK3β and pS9GSK3β in normal human tissue has been largely unknown. Thus, we examined the immunohistochemical localization of GSK3β and pS9GSK3β in human fetal and adult tissues, and also compared the expression pattern of GSK3β and pS9GSK3β with that of the CK7 and CK20. We found GSK3β expression in neurons of brain, myenteric plexus in gastrointestinal tract, squamous epithelium of skin, and mammary gland. The expression of pS9GSK3β was restricted to the epithelial cells of breast and pancreaticobiliary duct, distal nephron of kidney, gastrointestinal tract, fallopian tube, epididymis, secretory cell of prostatic gland, and umbrella cell of urinary tract. The staining pattern of pS9GSK3β and CK7 was overlapped in most organs except for gastrointestinal tract where CK7 was negative and CK20 was positive. Our results show that the expression of GSK3β may be associated with differentiation of ectodermal derived tissues and pS9GSK3β with that of epithelial cells of endodermal derived tissues in human. In addition, the expression of pS9GSK3β in the selective epithelial cells may indicate its association with secretory or barrier function of specific cells and may serve as another immunohistochemical marker for epithelial cells.

  16. Preliminary Design Study of a Pre-booster Damping Ring for the FCC e+e− Injector

    CERN Document Server

    Etisken, O; Papaphilippou, Y

    2017-01-01

    The aim of the FCC e+e− lepton collider is to collide particles in the energy range 40–175 GeV. The FCC e+e− injector complex needs to produce and transport high-intensity e+e− beams at a fast repetition rate of about 0.1 Hz to top up the collider at its collision energy. A basic parameter set exists for all collider energies, assuming a 10 GeV linac operating with a large number of bunches accumulating in the existing SPS, which serves as pre-accelerator and damping ring before the bunches are transferred to the high-energy booster. The purpose of this study is to provide the conceptual design of an alternative damping and accelerator ring, replacing the SPS in the current scheme. This ring will have an injection energy of around 6 GeV and an extraction energy of around 20 GeV. Apart from establishing the basic ring parameters, the final study will include the optics design and layout, and single particle linear and non-linear dynamics optimization, including magnetic and alignment error tolerances. ...

  17. Motor-generator set of the PS main supply

    CERN Multimedia

    Photographic Service; CERN PhotoLab

    1968-01-01

    Already in 1964, the PS improvement programme included a new main magnet supply with more power for the longer cycles needed for slow extraction at the full energy of 26 GeV. This motor-generator set was installed in 1967 and took up service at the beginning of 1968. Regularly serviced and fitted with modern electronic regulation, it pulses the PS to this day.

  18. A transmissão psíquica geracional

    Directory of Open Access Journals (Sweden)

    Vinícius Oliveira dos Santos

    Full Text Available O artigo seguinte refere-se a um estudo sobre como ocorre a transmissão psíquica entre as gerações e qual sua importância na constituição psíquica do sujeito. É também objetivo deste artigo explicar o que são as transmissões intergeracional e transgeracional. Para buscar respostas para essas questões, fez-se uma pesquisa bibliográfica sobre a transmissão psíquica, pelo viés psicanalítico, principalmente a partir da teoria lacaniana e com conceitos oriundos da linguística saussuriana. Será a partir de uma determinada ordem simbólica, constituída pela linguagem que precede o sujeito, nomeado por Lacan como o Outro, que a transmissão psíquica entre gerações ganhará o seu caráter unívoco, sempre se tendo em mente a importância fundamental do recalcamento e de seus efeitos, bem como do retorno do recalcado nas diferentes gerações. A transmissão psíquica é necessária e concomitante à constituição do sujeito, e ocorre através da linguagem, dos significantes que irão determinar uma ordem simbólica para o ser que nasce através dos diferentes discursos que perpassam as gerações nas figuras dos pais desse novo ser. Essa ordem simbólica continuará a se fazer presente nesse novo sujeito pelo restante de sua existência. Este artigo busca dar nova luz ao aspecto da transmissão psíquica transgeracional, diferenciando-se da recalque s abordagens psicanalíticas contemporâneas por ser uma leitura lacaniana. Serão usados dois exemplos: um de como a transmissão aparece na cultura, outro, na subjetividade do sujeito através da arte.

  19. Ultra-short-course booster is effective in recurrent grass pollen-induced allergic rhinoconjunctivitis.

    Science.gov (United States)

    Pfaar, O; Lang, S; Pieper-Fürst, U; Astvatsatourov, A; Gerich, F; Klimek, L; Kramer, M F; Reydelet, Y; Shah-Hosseini, K; Mösges, R

    2018-01-01

    A relevant proportion of allergic rhinoconjunctivitis (ARC) patients experience recurrent symptoms after successfully completing allergen immunotherapy (AIT). This prospective, controlled, noninterventional study used internationally standardized instruments to determine the clinical effects of a preseasonal, ultra-short-course booster AIT on clinical outcome parameters. This two-arm study included patients aged ≥12 years with recurrent grass pollen-induced seasonal AR who had completed a successful course of any grass pollen AIT at least 5 years before enrolment. Overall, 56 patients received one preseasonal short-course booster AIT using tyrosine-absorbed grass pollen allergoids containing the adjuvant monophosphoryl lipid A (MPL ® ); 51 control patients received symptomatic medication. The combined symptom and medication score (CSMS) was recorded in the (peak) grass pollen season. Furthermore, concomitant (antiallergic) medication use, the patients' state of health, Mini Rhinoconjunctivitis Quality of Life Questionnaire (MiniRQLQ) results and safety/tolerability of the treatment were assessed. The CSMS in the peak grass pollen season was significantly lower in the booster AIT group (Δ=38.4%, Pallergoids containing the adjuvant MPL ® effectively prevents re-occurrence of symptoms in patients with grass pollen-induced ARC. © 2017 The Authors. Allergy Published by John Wiley & Sons Ltd.

  20. Active immunisation of horses against tetanus including the booster dose and its application.

    Science.gov (United States)

    Liefman, C E

    1981-02-01

    Successful active immunisation of horses against tetanus is dependent on a number of factors of which the toxoid preparation used, its method of application and the ability of the individual horse to respond are fundamental. Two immunisation schedules using an aluminium-based toxoid preparation were examined and the protection determined by monitoring the level of antitoxin afforded by each schedule. The results obtained demonstrated that 2 doses of this toxoid are necessary to ensure 12 months protection in all horses. These results are discussed in relation to the factors involved in active immunisation against tetanus. Reference is also made to the occurrence of a transient phase of reduced levels of antitoxin following booster doses of toxoid in immunised horses during which it is considered these horses could become more susceptible to tetanus. The effect of a booster dose on immunised horses was examined and while there can be a reduction in the level of antitoxin in some immunised horses following this dose its effect is minimal, short-lived and for all practical purposes can be disregarded. The application of the booster dose in practice is also discussed.

  1. Probability-of-Superiority SEM (PS-SEM—Detecting Probability-Based Multivariate Relationships in Behavioral Research

    Directory of Open Access Journals (Sweden)

    Johnson Ching-Hong Li

    2018-06-01

    Full Text Available In behavioral research, exploring bivariate relationships between variables X and Y based on the concept of probability-of-superiority (PS has received increasing attention. Unlike the conventional, linear-based bivariate relationship (e.g., Pearson's correlation, PS defines that X and Y can be related based on their likelihood—e.g., a student who is above mean in SAT has 63% likelihood of achieving an above-mean college GPA. Despite its increasing attention, the concept of PS is restricted to a simple bivariate scenario (X-Y pair, which hinders the development and application of PS in popular multivariate modeling such as structural equation modeling (SEM. Therefore, this study addresses an empirical-based simulation study that explores the potential of detecting PS-based relationship in SEM, called PS-SEM. The simulation results showed that the proposed PS-SEM method can detect and identify PS-based when data follow PS-based relationships, thereby providing a useful method for researchers to explore PS-based SEM in their studies. Conclusions, implications, and future directions based on the findings are also discussed.

  2. Perpendicular biased ferrite tuned RF cavity for the TRIUMF KAON Factory booster ring

    International Nuclear Information System (INIS)

    Poirier, R.L.; Enegren, T.; Haddock, C.

    1989-03-01

    The rf cavity for the booster ring requires a frequency swing of 46 MHz to 62 MHz at a repetition rate of 50 Hz. The possibility of using the LANL booster cavity design with a yttrium garnet ferrite tuner biased perpendicular to the rf field, in the longitudinal direction, is being investigated. In order to minimize the stray magnetic biasing field on the beam axis, an alternative scheme similar to the design being proposed for the LANL main ring cavity in which the ferrite is perpendicular biased in the radial direction, is being considered. The behaviour of the rf cavity and the magnetizing circuit for both designs are discussed

  3. Intron-exon organization of the active human protein S gene PS. alpha. and its pseudogene PS. beta. : Duplication and silencing during primate evolution

    Energy Technology Data Exchange (ETDEWEB)

    Ploos van Amstel, H.; Reitsma, P.H.; van der Logt, C.P.; Bertina, R.M. (University Hospital, Leiden (Netherlands))

    1990-08-28

    The human protein S locus on chromosome 3 consists of two protein S genes, PS{alpha} and PS{beta}. Here the authors report the cloning and characterization of both genes. Fifteen exons of the PS{alpha} gene were identified that together code for protein S mRNA as derived from the reported protein S cDNAs. Analysis by primer extension of liver protein S mRNA, however, reveals the presence of two mRNA forms that differ in the length of their 5{prime}-noncoding region. Both transcripts contain a 5{prime}-noncoding region longer than found in the protein S cDNAs. The two products may arise from alternative splicing of an additional intron in this region or from the usage of two start sites for transcription. The intron-exon organization of the PS{alpha} gene fully supports the hypothesis that the protein S gene is the product of an evolutional assembling process in which gene modules coding for structural/functional protein units also found in other coagulation proteins have been put upstream of the ancestral gene of a steroid hormone binding protein. The PS{beta} gene is identified as a pseudogene. It contains a large variety of detrimental aberrations, viz., the absence of exon I, a splice site mutation, three stop codons, and a frame shift mutation. Overall the two genes PS{alpha} and PS{beta} show between their exonic sequences 96.5% homology. Southern analysis of primate DNA showed that the duplication of the ancestral protein S gene has occurred after the branching of the orangutan from the African apes. A nonsense mutation that is present in the pseudogene of man also could be identified in one of the two protein S genes of both chimpanzee and gorilla. This implicates that silencing of one of the two protein S genes must have taken place before the divergence of the three African apes.

  4. Evaluation of Recycling Polystyrene (PS) from a Microbiology Product

    OpenAIRE

    Eklöf, Jonas

    2014-01-01

    Detta är ett beställningsarbete av Plastone Oy och i det undersöks möjligheterna vad man kan göra genom återvinning med avfallsmaterialet som uppstår då man tillverkar en mikrobiologisk produkt i deras plastfabrik. Produkten tillverkas genom formsprutning och materialet som används är polystyren (PS). Ur litteraturstudien fann man varierande möjligheter på hur man kan återvinna PS på bästa sätt, men ingen lösning som har varit effektiv i praktiken. Det framgick också att återvunnet PS inte är...

  5. Motor-Generator powering the PS (Proton Synchrotron) main magnets

    CERN Multimedia

    1983-01-01

    This motor-generator,30 MW peak, 1500 r.p.m.,pulsed power supply for the PS main magnet replaced in 1968 the initial 3000 r.p.m. motor-generator-flywheel set which had served from the PS start-up in 1959 until end 1967. See also photo 8302337 and its abstract.

  6. The surface properties of PS/PMMA blends nanostructured polymeric layers

    International Nuclear Information System (INIS)

    Prosycevas, I.; Tamulevicius, S.; Guobiene, A.

    2004-01-01

    Solvent cast thin films of blends polystyrene (PS) and poly (methylmethacrylate) (PMMA) with nominal compositions ranging from 25/75 wt.%/v% (w/v) up to 75/25 w/v PS/PMMA with toluene as the mutual solvent on crystalline Si (100) and silica substrates has been studied. Films of PS and PMMA blends have been examined by atomic force microscopy (AFM) and ellipsometry. The blend films with less than 50% PMMA bulk concentration generally exhibit pitted surfaces; the pit size varies with film thickness and bulk composition. When the PMMA bulk concentration is greater than 50%, the film surface can be described as island-like phase-separated structure. The surface segregation and morphology are explained in terms of solubility of the two polymers in the solvent and rewetting of PMMA relative to PS

  7. A new one-man submarine is tested as vehicle for solid rocket booster retrieval

    Science.gov (United States)

    2000-01-01

    - The one-man submarine known as DeepWorker 2000 is tested in Atlantic waters near Cape Canaveral, Fla. Nearby are divers; inside the sub is the pilot, Anker Rasmussen. The sub is being tested on its ability to duplicate the sometimes hazardous job United Space Alliance (USA) divers perform to recover the expended boosters in the ocean after a launch. The boosters splash down in an impact area about 140 miles east of Jacksonville and after recovery are towed back to KSC for refurbishment by the specially rigged recovery ships. DeepWorker 2000 will be used in a demonstration during retrieval operations after the upcoming STS-101 launch. The submarine pilot will demonstrate capabilities to cut tangled parachute riser lines using a manipulator arm and attach a Diver Operator Plug to extract water and provide flotation for the booster. DeepWorker 2000 was built by Nuytco Research Ltd., North Vancouver, British Columbia. It is 8.25 feet long, 5.75 feet high, and weighs 3,800 pounds. USA is a prime contractor to NASA for the Space Shuttle program.

  8. BSF control system

    International Nuclear Information System (INIS)

    Irie, Y.; Ishii, K.; Ninomiya, S.; Sasaki, H.; Sakai, I.

    1982-08-01

    The booster synchrotron utilization facility (BSF) is a facility which utilizes the four fifths of available beam pulses from the KEK booster synchrotron. The BSF control system includes the beam line control, interactions with the PS central control room and the experimental facilities, and the access control system. A brief description of the various components in the control system is given. (author)

  9. Effectiveness of early adalimumab therapy in psoriatic arthritis patients from Reuma.pt - EARLY PsA.

    Science.gov (United States)

    Santos, Helena; Eusébio, Mónica; Borges, Joana; Gonçalves, Diana; Ávila-Ribeiro, Pedro; Faria, Daniela Santos; Lopes, Carina; Rovisco, João; Águeda, Ana; Nero, Patrícia; Valente, Paula; Cravo, Ana Rita; Santos, Maria José

    2017-01-01

    Objective To compare outcomes in psoriatic arthritis (PsA) patients initiating adalimumab (ADA), with short- and long-term disease duration and to evaluate the potential effect of concomitant conventional synthetic disease-modifying antirheumatic drugs (csDMARD) or glucocorticoids. Methods Analyses included adult PsA patients registered in the Rheumatic Diseases Portuguese Register (Reuma.pt) between June 2008-June 2016 who received ADA for ≥3 months. Psoriatic Arthritis Response Criteria (PsARC) response, tender and swollen joint count, inflammatory parameters, patient (PtGA) and physician global assessment (PhGA), Disease Activity Score-28 joints (DAS28), and Health Assessment Questionnaire Disability Index (HAQ-DI) were compared between patients with PsA) and those with ≥5 years of disease duration (late PsA). Time to achieving PsARC response was estimated using the Kaplan-Meier method. Results Of 135 PsA patients treated with ADA, 126 had information on disease duration (earlyPsA, n=41). PsARC response was achieved by 72.9% of the patients (88.0% early PsA vs 62.2% late PsA; P=0.022) after 3 months and by 85.4% after 24 months (100% early PsA vs 75.9% late PsA; P=0.044). Early PsA patients achieved significantly less painful joints (2.7 vs 6.7, p=0.006), lower mean C-reactive protein (0.5 mg/dL vs 1.3 mg/dL; P=0.011), and PhGA (18.3 vs 28.1; P=0.020) at 3 months. In the long term, early PsA patients also had fewer swollen joints (0.3 vs 1.7; P=0.030) and lower PhGA (6.3 vs 21.9; PPsA, respectively. Early PsA patients obtained PsARC response more rapidly than late PsA (3.8 and 7.4 months, respectively; P=0.008). Concomitant csDMARDs showed clinical benefit (2-year PsARC response, 88.3% vs 60.0%; P=0.044). Concomitant glucocorticoids had no effect on PsARC response over 2 years of follow-up. Persistence on ADA was similar in both groups. Conclusion Early PsA patients had a greater chance of improvement after ADA therapy and better functional outcome, and

  10. Design and optimization of a large flow rate booster pump in SWRO energy recovery system

    International Nuclear Information System (INIS)

    Lai, Z N; Wu, P; Wu, D Z; Wang, L Q

    2013-01-01

    Seawater reverse osmosis (SWRO) is a high energy-consumption industry, so energy efficiency is an important issue. Energy recovery systems, which contain a pressure exchanger and a booster pump, are widely used in SWRO plants. As a key part of energy recovery system, the difficulty of designing booster pumps lies in high inlet pressure, high medium causticity and large flow rate. High inlet pressure adds difficulties to seal design, and large flow rate and high efficiency requirement bring high demand for hydraulic design. In this paper, a 625 m 3 /h booster pump is designed and optimized according to the CFD (Computational Fluid Dynamics) simulation results. The impeller and volute is well designed, a new type of high pressure mechanical seal is applied and axial force is well balanced. After optimization based on blade redesign, the efficiency of the pump was improved. The best efficiency reaches more than 85% at design point according to the CFD simulation result

  11. Design and optimization of a large flow rate booster pump in SWRO energy recovery system

    Science.gov (United States)

    Lai, Z. N.; Wu, P.; Wu, D. Z.; Wang, L. Q.

    2013-12-01

    Seawater reverse osmosis (SWRO) is a high energy-consumption industry, so energy efficiency is an important issue. Energy recovery systems, which contain a pressure exchanger and a booster pump, are widely used in SWRO plants. As a key part of energy recovery system, the difficulty of designing booster pumps lies in high inlet pressure, high medium causticity and large flow rate. High inlet pressure adds difficulties to seal design, and large flow rate and high efficiency requirement bring high demand for hydraulic design. In this paper, a 625 m3/h booster pump is designed and optimized according to the CFD (Computational Fluid Dynamics) simulation results. The impeller and volute is well designed, a new type of high pressure mechanical seal is applied and axial force is well balanced. After optimization based on blade redesign, the efficiency of the pump was improved. The best efficiency reaches more than 85% at design point according to the CFD simulation result.

  12. Antagonist of peroxisome proliferator-activated receptor γ induces cerebellar amyloid-β levels and motor dysfunction in APP/PS1 transgenic mice

    International Nuclear Information System (INIS)

    Du, Jing; Sun, Bing; Chen, Kui; Fan, Li; Wang, Zhao

    2009-01-01

    Recent evidences show that peroxisome proliferator-activated receptor γ (PPARγ) is involved in the modulation of the amyloid-β (Aβ) cascade causing Alzheimer's disease (AD) and treatment with PPARγ agonists protects against AD pathology. However, the function of PPARγ steady-state activity in Aβ cascade and AD pathology remains unclear. In this study, an antagonist of PPARγ, GW9662, was injected into the fourth ventricle of APP/PS1 transgenic mice to inhibit PPARγ activity in cerebellum. The results show that inhibition of PPARγ significantly induced Aβ levels in cerebellum and caused cerebellar motor dysfunction in APP/PS1 transgenic mice. Moreover, GW9662 treatment markedly decreased the cerebellar levels of insulin-degrading enzyme (IDE), which is responsible for the cellular degradation of Aβ. Since cerebellum is spared from significant Aβ accumulation and neurotoxicity in AD patients and animal models, these findings suggest a crucial role of PPARγ steady-state activity in protection of cerebellum against AD pathology.

  13. CoPs Facing Rationalization: The Politics of Community Reproduction

    Science.gov (United States)

    Kilskar, Stine Skaufel; Ingvaldsen, Jonas A.; Valle, Nina

    2018-01-01

    Purpose: This paper aims to explore the relationship between the contemporary forms of manufacturing rationalization and the reproduction of communities of practice (CoPs) centred on tasks and craft. Building on critical literature highlighting the tensions between CoPs and rationalization, this paper aims to develop a nuanced account of how CoPs…

  14. Antiphosphatidylserine/prothrombin antibodies (aPS/PT) as potential markers of antiphospholipid syndrome.

    Science.gov (United States)

    Vlagea, Alexandru; Gil, Antonio; Cuesta, Maria V; Arribas, Florencia; Diez, Jesús; Lavilla, Paz; Pascual-Salcedo, Dora

    2013-06-01

    The antiphospholipid antibodies present in antiphospholipid syndrome (APS) are directed at a number of phospholipid-binding proteins: β2 glycoprotein I (β2GPI), prothrombin, and so on. Antibodies directed at β2GPI are accepted as a classification criterion for APS, while the presence of antiprothrombin antibodies is not. In the present article, we investigated the possible role of antiphosphatidylserine/prothrombin antibodies (aPS/PT) as marker of APS on a cohort of 295 individuals with APS (95 primary APS and 45 secondary APS) and APS-related diseases. We found aPS/PT to be highly associated with venous thrombosis (immunoglobulin G [IgG] aPS/PT odds ratio [OR], 7.44; 95% confidence interval [CI], 3.97-13.92 and IgM aPS/PT OR, 2.54; 95% CI, 1.35-4.77) and obstetric abnormalities (IgG aPS/PT OR, 2.37; 95% CI, 1.04-5.43), but not with arterial thrombosis. A very high degree of concordance between the concentration of aPS/PT and lupus anticoagulant activity was demonstrated. Therefore, we support the inclusion of aPS/PT determination as second-level assay to confirm APS classification.

  15. Project of Ariane 5 LV family advancement by use of reusable fly-back boosters (named “Bargouzine”)

    Science.gov (United States)

    Sumin, Yu.; Bonnal, Ch.; Kostromin, S.; Panichkin, N.

    2007-12-01

    The paper concerns possible concept variants of a partially reusable Heavy-Lift Launch Vehicle derived from the advanced basic launcher (Ariane-2010) by means of substitution of the EAP Solid Rocket Boosters for a Reusable Starting Stage consisting two Liquid-propellant Reusable Fly-Back Boosters called "Bargouzin". This paper describes the status of the presently studied RFBB concepts during its three phases. The first project phase was dedicated to feasibility expertise of liquid-rocket reusable fly-back boosters ("Baikal" type) utilization for heavy-lift space launch vehicle. The design features and main conclusions are presented. The second phase has been performed with the purpose of selection of preferable concept among the alternative ones for the future Ariane LV modernization by using RFBB instead of EAP Boosters. The main requirements, logic of work, possible configuration and conclusion are presented. Initial aerodynamic, ballistic, thermoloading, dynamic loading, trade-off and comparison analysis have been performed on these concepts. The third phase consists in performing a more detailed expertise of the chosen LV concept. This part summarizes some of the more detailed results related to flight performance, system mass, thermoprotection system, aspects of technologies, ground complex modification, comparison analyses and conclusion.

  16. Does a booster intervention augment the preventive effects of an abbreviated version of the coping power program for aggressive children?

    Science.gov (United States)

    Lochman, John E; Baden, Rachel E; Boxmeyer, Caroline L; Powell, Nicole P; Qu, Lixin; Salekin, Karen L; Windle, Michel

    2014-01-01

    Booster interventions have been presumed to be important methods for maintaining the effects of evidence-based programs for children with behavioral problems, but there has been remarkably little empirical attention to this assumption. The present study examines the effect of a child-oriented booster preventive intervention with children who had previously received an abbreviated version (24 child sessions, 10 parent sessions) of the Coping Power targeted prevention program. Two hundred and forty-one children (152 boys, 89 girls) were screened as having moderate to high levels of aggressive behavior in 4th grade, then half were randomly assigned to receive the abbreviated Coping Power program in 5th grade, and half of the preventive intervention children were then randomly assigned to a Booster condition in 6th grade. The Booster sessions consisted of brief monthly individual contacts, and were primarily with the children. Five assessments across 4 years were collected from teachers, providing a three-year follow-up for all children who participated in the project. Results indicated that the abbreviated Coping Power program (one-third shorter than the full intervention) had long-term effects in reducing children's externalizing problem behaviors, proactive and reactive aggression, impulsivity traits and callous-unemotional traits. The Booster intervention did not augment these prevention effects. These findings indicate that a briefer and more readily disseminated form of an evidence-based targeted preventive intervention was effective. The findings have potential implications for policy and guidelines about possible intervention length and booster interventions.

  17. Beyond the Point Ps Approximation

    OpenAIRE

    Stepanov, Sergey V.; Zvezhinskiy, Dmitry S.; Byakov, Vsevolod M.

    2012-01-01

    In application to positron annihilation spectroscopy, Ps atom is considered not as a point particle, but as a finite size e+ e- pair localized in a bubble-state in a medium. Variation of the internal Coulombic e+ -e- attraction vs. the bubble radius is estimated.

  18. Implementation of electron beam position measurement algorithm and embedded web server using MCS-51 microcontroller for Booster Synchrotron

    International Nuclear Information System (INIS)

    Shrivastava, B.B.; Chouhan, Manish; Puntambekar, T.A.; Tiwari, A.N.

    2015-01-01

    The Booster Synchrotron at RRCAT caters as Injector Machine for Indus-1 and Indus-2 with the repetition rate of 1Hz. In Booster Synchrotron, energy of electron bunches are increased from 20 MeV to 450 MeV (in ∼ 280 ms) and 550 MeV (in ∼ 340 ms ) for Indus-1 and Indus-2 respectively. An algorithm for microcontroller based beam position measurement system has been developed for the Booster Synchrotron to measure the fast changes in the beam position of electron bunches during energy ramping. In this paper, software implementation in microcontroller and its optimization to achieve beam position update rate of 1 kHz is discussed. (author)

  19. Numerical model for thermoeconomic diagnosis in commercial transcritical/subcritical booster refrigeration systems

    International Nuclear Information System (INIS)

    Ommen, Torben; Elmegaard, Brian

    2012-01-01

    Highlights: ► A transcritical booster refrigeration plant is modelled. ► We examine changes in cost flow at different operation parameters. ► The use of characteristic curves for diagnosis is studied. - Abstract: Transcritical/subcritical booster refrigeration systems are increasingly installed and used in Danish supermarkets. The systems operate in both transcritical and subcritical conditions dependent on the heat rejection performance and the ambient conditions. The plant consists of one refrigerant cycle supplying refrigerant for evaporators in both chilled and frozen display cases. In the paper, thermoeconomic theory is used to establish the cost of cooling at each individual temperature level based on operating costs. With a high amount of operating systems, faulty operation becomes an economic, and environmental, interest. A general solution for evaluation of these systems is considered, with the objective to reduce cost and power consumption of malfunctioning equipment in operation. An analysis of the use of thermoeconomic diagnosis methods is required, as these methods may prove applicable. To accommodate the analysis, a numerical model of a transcritical booster refrigeration plant is considered in this paper. Additionally the characteristic curves method is applied to the high pressure compressor unit of the refrigeration plant. The approach successfully determine whether an anomaly is intrinsic or induced in the component when no uncertainties are introduced in the steady state model.

  20. Studies on the construction of a new 80 MeV injector and a new injection scheme for the synchrotron of the Bonn accelerator facility ELSA; Studien zum Aufbau eines neuen 80 MeV-Injektors und eines neuen Injektionsschemas fuer das Synchroton der Bonner Beschleunigeranlage ELSA

    Energy Technology Data Exchange (ETDEWEB)

    Raecke, K.

    2001-09-01

    At the ELSA Accelerator Facility exists the opportunity to install a 80 MeV linear accelerator as an injector for the 2,5 GeV Booster Synchrotron. Because of its length the new structure cannot replace one of the linacs used today so possibilities to built up the accelerator and the transfer channels are worked out. Calculations comparing the injection efficiency of the present layout and the possible new layout show a recognizable improvement. The injection efficiency can be further improved using a single turn injection scheme. A septum magnet and a fast kicker for this injection scheme is designed. (orig.)

  1. Role of trapped and solvated electrons in Ps formation

    International Nuclear Information System (INIS)

    Stepanov, S.V.; Byakov, V.M.; Mikhin, K.V.; He, C.; Hirade, T.

    2005-01-01

    Role of trapped and solvated electrons in Ps formation is discussed. Combination of thermalized positron with such electrons is possible from the view point of the energy balance and may results in Ps formation. This process proceeds during all e = lifetime matter. Fitting of raw experimental e + -e - annihilation spectra has to be based on an adequate physical input, which often leads to necessity of nonexponential deconvolution of the spectra. We have interpreted the Ps formation data in polyethylene, ethylene-methylmethacrylate and polymethylmethacrylate in dark and in light vs. tome of the measurement and temperature. parameters characterized accumulation of trapped electrons and their recombination with counter ions and positrons are obtained. (author)

  2. Stability of FDTS monolayer coating on aluminum injection molding tools

    International Nuclear Information System (INIS)

    Cech, Jiri; Taboryski, Rafael

    2012-01-01

    Highlights: ► We present novel and highly useful results on FDTS monolayer coating of aluminum. ► The coating is particularly applicable for coating of prototyping injection molding tools, which often are made of Al. ► We have demonstrated that the coating prevails in injection molding conditions and that the coating will prevent wear of the tools. - Abstract: We have characterized perfluorodecyltrichlorosilane (FDTS) molecular coating of aluminum molds for polymer replication via injection molding (IM). X-ray photoelectron spectroscopy (XPS) data, sessile drop contact angles with multiple fluids, surface energies and roughness data have been collected. Samples have been characterized immediately after coating, after more than 500 IM cycles to test durability, and after 7 months to test temporal stability. The coating was deposited in an affordable process, involving near room temperature gas phase reactions. XPS shows detectable fluorine presence on both freshly coated samples as well as on post-IM samples with estimated 30 at.% on freshly coated and 28 at.% on post-IM samples with more than 500 IM cycles with polystyrene (PS) and ABS polymer.

  3. Clinical and Patient-reported Outcomes in Patients with Psoriatic Arthritis (PsA) by Body Surface Area Affected by Psoriasis: Results from the Corrona PsA/Spondyloarthritis Registry.

    Science.gov (United States)

    Mease, Philip J; Karki, Chitra; Palmer, Jacqueline B; Etzel, Carol J; Kavanaugh, Arthur; Ritchlin, Christopher T; Malley, Wendi; Herrera, Vivian; Tran, Melody; Greenberg, Jeffrey D

    2017-08-01

    Psoriatic arthritis (PsA) is commonly comorbid with psoriasis; the extent of skin lesions is a major contributor to psoriatic disease severity/burden. We evaluated whether extent of skin involvement with psoriasis [body surface area (BSA) > 3% vs ≤ 3%] affects overall clinical and patient-reported outcomes (PRO) in patients with PsA. Using the Corrona PsA/Spondyloarthritis Registry, patient characteristics, disease activity, and PRO at registry enrollment were assessed for patients with PsA aged ≥ 18 years with BSA > 3% versus ≤ 3%. Regression models were used to evaluate associations of BSA level with outcome [modified minimal disease activity (MDA), Health Assessment Questionnaire (HAQ) score, patient-reported pain and fatigue, and the Work Productivity and Activity Impairment questionnaire score]. Adjustments were made for age, sex, race, body mass index, disease duration, and history of biologics, disease-modifying antirheumatic drug, and prednisone use. This analysis included 1240 patients with PsA with known BSA level (n = 451, BSA > 3%; n = 789, BSA ≤ 3%). After adjusting for potential confounding variables, patients with BSA > 3% versus ≤ 3% had greater patient-reported pain and fatigue and higher HAQ scores (p = 2.33 × 10 -8 , p = 0.002, and p = 1.21 × 10 -7 , respectively), were 1.7× more likely not to be in modified MDA (95% CI 1.21-2.41, p = 0.002), and were 2.1× more likely to have overall work impairment (1.37-3.21, p = 0.0001). These Corrona Registry data show that substantial skin involvement (BSA > 3%) is associated with greater PsA disease burden, underscoring the importance of assessing and effectively managing psoriasis in patients with PsA because this may be a contributing factor in PsA severity.

  4. People and things. CERN Courier, Jun 1979, v. 19(4)

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    On 1 April, six months ahead of schedule, electrons were injected into the 8 GeV electron-positron storage ring, CESR, at Cornell. Two weeks later beam was accumulated at an energy of 5.5 GeV. The contract for the management and construct/on of the conventional facilities of the ISABELLE 400 GeV proton storage rings to be built at the Brookhaven Laboratory has been awarded to the New York firm of Ammann and Whitney. Greatly helped by the quality of the beams from the new linac, the CERN 800 MeV four-ring Booster has achieved several new records which bode well for the role it has to play with the PS in feeding the high energy machines in the coming years

  5. People and things. CERN Courier, Jun 1979, v. 19(4)

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1979-06-15

    On 1 April, six months ahead of schedule, electrons were injected into the 8 GeV electron-positron storage ring, CESR, at Cornell. Two weeks later beam was accumulated at an energy of 5.5 GeV. The contract for the management and construct/on of the conventional facilities of the ISABELLE 400 GeV proton storage rings to be built at the Brookhaven Laboratory has been awarded to the New York firm of Ammann and Whitney. Greatly helped by the quality of the beams from the new linac, the CERN 800 MeV four-ring Booster has achieved several new records which bode well for the role it has to play with the PS in feeding the high energy machines in the coming years.

  6. An expert system in the accelerator domain

    International Nuclear Information System (INIS)

    Malandain, E.

    1990-01-01

    Methods developed for artificial intelligence can be applied with success for certain classes of problems. One such class of problems is the diagnostic task. The diagnostic problem is relatively well understood theoretically and there exists now a diversity of tools to facilitate the implementation of diagnostic systems. This paper describes how a prototype for diagnosing problems in the injection line of the PS Booster at CERN was built. I shall discuss the reasons why it was built, how the knowledge is represented, how the inferencing is done and the environment. What has been achieved and the conclusion at the experiment will be shown. This paper is an updated version of a talk given at the CERN School of computing Bad Herrenalb, Federal Republic of Germany, 1989

  7. First-in-human safety and immunogenicity investigations of three adjuvanted reduced dose inactivated poliovirus vaccines (IPV-Al SSI) compared to full dose IPV Vaccine SSI when given as a booster vaccination to adolescents with a history of IPV vaccination at 3, 5, 12months and 5years of age.

    Science.gov (United States)

    Lindgren, Line M; Tingskov, Pernille N; Justesen, Annette H; Nedergaard, Bettina S; Olsen, Klaus J; Andreasen, Lars V; Kromann, Ingrid; Sørensen, Charlotte; Dietrich, Jes; Thierry-Carstensen, Birgit

    2017-01-23

    There is a demand of affordable IPV in the World. Statens Serum Institut (SSI) has developed three reduced dose IPV formulations adsorbed to aluminium hydroxide; 1/3 IPV-Al, 1/5 IPV-Al and 1/10 IPV-Al SSI, and now report the results of the first investigations in humans. 240 Danish adolescents, aged 10-15years, and childhood vaccinated with IPV were booster vaccinated with 1/3 IPV-Al, 1/5 IPV-Al, 1/10 IPV-Al or IPV Vaccine SSI. The booster effects (GMTRs) of the three IPV-Al SSI were compared to IPV Vaccine SSI, and evaluated for non-inferiority. The pre-vaccination GMTs were similar across the groups; 926 (type 1), 969 (type 2) and 846 (type 3) in the total trial population. The GMTRs by poliovirus type and IPV formulation were: Type 1: 17.0 (1/3 IPV-Al), 13.0 (1/5 IPV-Al), 7.1 (1/10 IPV-Al) and 42.2 (IPV Vaccine SSI). Type 2: 12.5 (1/3 IPV-Al), 13.1 (1/5 IPV-Al), 7.6 (1/10 IPV-Al) and 47.8 (IPV Vaccine SSI). Type 3: 14.5 (1/3 IPV-Al), 16.2 (1/5 IPV-Al), 8.9 (1/10 IPV-Al) and 62.4 (IPV Vaccine SSI) Thus, the three IPV-Al formulations were highly immunogenic, but inferior to IPV Vaccine SSI, in this booster vaccination trial. No SAE and no AE of severe intensity occurred. 59.2% of the subjects reported at least one AE. Injection site pain was the most frequent AE in all groups; from 24.6% to 43.3%. Injection site redness and swelling frequencies were<5% in most and<10% in all groups. The most frequent systemic AEs were fatigue (from 8.2% to 15.0%) and headache (from 15.0% to 28.3%). Most AEs were of mild intensity. In conclusion, the three IPV-Al SSI were safe in adolescents and the booster effects were satisfactory. ClinicalTrials.gov registration number: NCT02280447. Copyright © 2016. Published by Elsevier Ltd.

  8. RF field control for KAON Factory booster cavities

    International Nuclear Information System (INIS)

    Craig, S.T.; de Jong, M.S.

    1990-11-01

    A conceptual design is developed for control of the KAON Factory Booster rf accelerating fields. This design addresses control of cavity: tuning, voltage amplitude, and voltage phase angle. Time-domain simulations were developed to evaluated the proposed controllers. These simulations indicated that adequate tuning performance can be obtained with the combination of adaptive feed-forward and proportional feedback control. Voltage amplitude and voltage phase can be adequately controlled using non-adaptive feedforward and proportional feedback control

  9. Jagiellonian University Advances in Ps Manipulations and Laser Studies in the AEgIS Experiment

    CERN Document Server

    Caravita, R; Amsler, C; Bonomi, G; Brusa, R S; Caccia, M; Castelli, F; Cerchiari, G; Comparat, D; Consolati, G; Demetrio, A; Di Noto, L; Doser, M; Evans, C; Ferragut, R; Fesel, J; Fontana, A; Gerber, S; Giammarchi, M; Gligorova, A; Guatieri, F; Haider, S; Hinterberger, A; Holmestad, H; Kellerbauer, A; Khalidova, O; Krasnický, D; Lagomarsino, V; Lansonneur, P; Lebrun, P; Malbrunot, C; Mariazzi, S; Marton, J; Matveev, V; Mazzotta, Z; Müller, S R; Nebbia, G; Nedelec, P; Oberthaler, M; Pacifico, N; Pagano, D; Penasa, L; Petracek, V; Prelz, F; Prevedelli, M; Ravelli, L; Rienäcker, B; Robert, J; Røhne, O M; Rotondi, A; Sandaker, H; Santoro, R; Smestad, L; Sorrentino, F; Testera, G; Tietje, I; Widmann, E; Yzombard, P; Zimmer, C; Zmeskal, J; Zurlo, N

    2017-01-01

    Positronium (Ps), the unstable bound state of electron and positron, is a valuable system for neutral antimatter spectroscopic studies and for antihydrogen production. Forming a pulsed beam cold antihydrogen using charge-exchange with the Rydberg Ps is the goal of the AEgIS Collaboration, which aims to measure gravity on neutral antimatter. Recent results achieved in producing, manipulating and studying Ps are summarized. Ps has been first produced with mesoporous silica targets in a reflection geometry. Spectroscopy of Ps n = 3 state has been conducted, yielding as a byproduct an independent estimate of the produced Ps temperature. Efficient laser excitation to the Rydberg levels was then achieved, validating the proof-of-concept of AEgIS. Subsequently, production of Ps from a new class of transmission targets was also achieved, opening the possibility for future experiments.

  10. DiPS: A Unifying Approach for developing System Software

    OpenAIRE

    Michiels, Sam; Matthijs, Frank; Walravens, Dirk; Verbaeten, Pierre

    2002-01-01

    In this paper we unify three essential features for flexible system software: a component oriented approach, self-adaptation and separation of concerns.We propose DiPS (Distrinet Protocol Stack), a component framework, which offers components, an anonymous interaction model and connectors to handle non-functional aspects such as concurrency. DiPS has effectively been used in industrial protocol stacks and device drivers.

  11. Modelling of Ne-like copper X-ray laser driven by 1.2 ps short pulse and 280 ps background pulse configuration

    International Nuclear Information System (INIS)

    Demir, A.; Kenar, N.; Goktas, H.; Tallents, G.J.

    2004-01-01

    Detailed simulations of Ne-like Cu x-ray laser are undertaken using the EHYBRID code. The atomic physics data are obtained using the Cowan code. The optimization calculations are performed in terms of the intensity of background and the time separation between the background and the short pulse. The optimum value is obtained for the conditions of a Nd:glass laser with 1.2 ps pulse at 4.4 x 10 15 W cm -2 irradiance pumping a plasma pre-formed by a 280 ps duration pulse at 5.4 x 10 12 W cm -2 with peak-to-peak pulse separation set at 300 ps. X-ray resonance lines between 6 A and 15 A emitted from copper plasmas have been simulated. Free-free and free-bound emission from the Si-, Al-, Mg-, Na-, Ne- and F-like ions is calculated in the simulation. (author)

  12. Framing-camera tube developed for sub-100-ps range

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    A new framing-camera tube, developed by Electronics Engineering, is capable of recording two-dimensional image frames with high spatial resolution in the sub-100-ps range. Framing is performed by streaking a two-dimensional electron image across narrow slits; the resulting electron-line images from the slits are restored into a framed image by a restorer deflector operating synchronously with the dissector deflector. We have demonstrated its performance in a prototype tube by recording 125-ps-duration framed images of 2.5-mm patterns. The limitation in the framing speed is in the external electronic drivers for the deflectors and not in the tube design characteristics. Shorter frame durations (below 100 ps) can be obtained by use of faster deflection drivers

  13. Electrophysical properties of PMN-PT-PS-PFN:Li ceramics

    Directory of Open Access Journals (Sweden)

    R. Skulski

    2013-01-01

    Full Text Available We present the technology of obtaining and the electrophysical properties of a multicomponent material 0.61PMN-0.20PT-0.09PS-0.1PFN:Li (PMN-PT-PS-PFN:Li. The addition of PFN into PMN-PT decreases the temperature of final sintering which is very important during technological process (addition of Li decreases electric conductivity of PFN. Addition of PS i.e., PbSnO3 (which is unstable in ceramic form permits to shift the temperature of the maximum of dielectric permittivity. One-step method of obtaining ceramic samples from oxides and carbonates has been used. XRD, microstructure, scanning calorimetry measurements and the main dielectric, ferroelectric and electromechanical properties have been investigated for the obtained samples.

  14. SAFETY: STRICTER CONTROLS IN CONTROLLED AREAS IN THE PS

    CERN Multimedia

    G. Daems

    2001-01-01

    The PS accelerators will soon stop for several months. Work will take place in controlled areas in the PS and will involve many people who are not always aware of the risks associated with the work sites. To guarentee the safety of these workers, the following two measures will be applied: everyone working in a controlled zone - Linacs, PSB, and PS machines tunnels, and transfer lines - must wear, visibly, his CERN access card and his film badge. the CERN access card and the film badge will only be issued after following a basic safety course. Regular checks will be carried out during the shutdown. Anyone without these two items on their person will be obliged to leave the area immediately.

  15. Beam Diagnosis and Lattice Modeling of the Fermilab Booster

    International Nuclear Information System (INIS)

    Huang, Xiaobiao

    2005-01-01

    A realistic lattice model is a fundamental basis for the operation of a synchrotron. In this study various beam-based measurements, including orbit response matrix (ORM) and BPM turn-by-turn data are used to verify and calibrate the lattice model of the Fermilab Booster. In the ORM study, despite the strong correlation between the gradient parameters of adjacent magnets which prevents a full determination of the model parameters, an equivalent lattice model is obtained by imposing appropriate constraints. The fitted gradient errors of the focusing magnets are within the design tolerance and the results point to the orbit offsets in the sextupole field as the source of gradient errors. A new method, the independent component analysis (ICA) is introduced to analyze multiple BPM turn-by-turn data taken simultaneously around a synchrotron. This method makes use of the redundancy of the data and the time correlation of the source signals to isolate various components, such as betatron motion and synchrotron motion, from raw BPM data. By extracting clean coherent betatron motion from noisy data and separates out the betatron normal modes when there is linear coupling, the ICA method provides a convenient means to measure the beta functions and betatron phase advances. It also separates synchrotron motion from the BPM samples for dispersion function measurement. The ICA method has the capability to separate other perturbation signals and is robust over the contamination of bad BPMs. The application of the ICA method to the Booster has enabled the measurement of the linear lattice functions which are used to verify the existing lattice model. The transverse impedance and chromaticity are measured from turn-by-turn data using high precision tune measurements. Synchrotron motion is also observed in the BPM data. The emittance growth of the Booster is also studied by data taken with ion profile monitor (IPM). Sources of emittance growth are examined and an approach to cure

  16. The four Ps of marketing mix in Information Science literature

    OpenAIRE

    Amaral, Sueli Angelica Do

    2000-01-01

    Analisa 60 documentos sobre os 4Ps do composto de marketing cm unidades de informação da literatura de Ciência da Informação no período de 1975 a 1995, para conhecer quantos e quais autores escreveram sobre o tema, qual o pioneiro, quem foi o pioneiro a propor adição de Ps. Apresenta a cronologia dos documentos estudados e discute as 4Ps do composto de marketing. Propõe a adoção da mais completa proposta analisada como forma de garantir o futuro das unidades de informação. ___________________...

  17. HiPS - Hierarchical Progressive Survey Version 1.0

    Science.gov (United States)

    Fernique, Pierre; Allen, Mark; Boch, Thomas; Donaldson, Tom; Durand, Daniel; Ebisawa, Ken; Michel, Laurent; Salgado, Jesus; Stoehr, Felix; Fernique, Pierre

    2017-05-01

    This document presents HiPS, a hierarchical scheme for the description, storage and access of sky survey data. The system is based on hierarchical tiling of sky regions at finer and finer spatial resolution which facilitates a progressive view of a survey, and supports multi-resolution zooming and panning. HiPS uses the HEALPix tessellation of the sky as the basis for the scheme and is implemented as a simple file structure with a direct indexing scheme that leads to practical implementations.

  18. Yalina booster subcritical assembly performance with low enriched uranium fuel

    International Nuclear Information System (INIS)

    Talamo, Alberto; Gohar, Yousry

    2011-01-01

    The YALINA Booster facility is a subcritical assembly located in Minsk, Belarus. The facility has special features that result in fast and thermal neutron spectra in different zones. The fast zone of the assembly uses a lead matrix and uranium fuels with different enrichments: 90% and 36%, 36%, or 21%. The thermal zone of the assembly contains 10% enriched uranium fuel in a polyethylene matrix. This study discusses the performance of the three YALINA Booster configurations with the different fuel enrichments. In order to maintain the same subcriticality level in the three configurations, the number of fuel rods in the thermal zone is increased as the uranium fuel enrichment in the fast zone is decreased. The maximum number of fuel rods that can be loaded in the thermal zone is about 1185. Consequently, the neutron multiplication of the configuration with 21% enriched uranium fuel in the fast zone is enhanced by changing the position of the boron carbide and the natural uranium absorber rods, located between the fast and the thermal zones, to form an annular rather than a square arrangement. (author)

  19. Yalina booster subcritical assembly performance with low enriched uranium fuel

    Energy Technology Data Exchange (ETDEWEB)

    Talamo, Alberto; Gohar, Yousry, E-mail: alby@anl.gov [Argonne National Laboratory, Lemont, IL (United States)

    2011-07-01

    The YALINA Booster facility is a subcritical assembly located in Minsk, Belarus. The facility has special features that result in fast and thermal neutron spectra in different zones. The fast zone of the assembly uses a lead matrix and uranium fuels with different enrichments: 90% and 36%, 36%, or 21%. The thermal zone of the assembly contains 10% enriched uranium fuel in a polyethylene matrix. This study discusses the performance of the three YALINA Booster configurations with the different fuel enrichments. In order to maintain the same subcriticality level in the three configurations, the number of fuel rods in the thermal zone is increased as the uranium fuel enrichment in the fast zone is decreased. The maximum number of fuel rods that can be loaded in the thermal zone is about 1185. Consequently, the neutron multiplication of the configuration with 21% enriched uranium fuel in the fast zone is enhanced by changing the position of the boron carbide and the natural uranium absorber rods, located between the fast and the thermal zones, to form an annular rather than a square arrangement. (author)

  20. Effect of oral booster vaccination of rainbow trout against Yersinia ruckeri depends on type of primary immunization

    DEFF Research Database (Denmark)

    Jaafar, Rzgar M.; Al-Jubury, Azmi; Dalsgaard, Inger

    2017-01-01

    provided as dip (most effective), bath (less effective) or orally (least effective). Oral immunization may be used as booster after dip but applied as a single oral application it induced merely a slight and statistically non-significant response. It is noteworthy that primary oral immunization followed...... already primed by one of these vaccination methods. Oral vaccination of trout (administering vaccine in feed) is an even more convenient way of presenting antigen to the fish but the effect of an oral booster has not previously been described in detail. The present work describes to what extent protection...... by an oral booster vaccination showed a trend for an even weaker response. It should be investigated if continued exposure to a low antigen concentration - as performed by two oral immunizations - may induce tolerance to the pathogen and thereby leave the fish more vulnerable....

  1. Physics with primary beams of the KEK-PS

    International Nuclear Information System (INIS)

    Tanaka, Kazuhiro; Yoshii, Masahito

    1993-08-01

    The 12-GeV Proton Synchrotron (PS) at the National Laboratory for High Energy Physics (KEK) has provided great opportunities to high-energy-physics and related communities as a unique high-energy hadron machine, since its operation in 1976. Activities of the KEK-PS are indispensable for the rapid development in the field. Six experimental subjects are proposed in this Report; (1) media effects in φ meson decay, (2) multifragmentation in high-energy reactions, (3) mechanism of high-energy reactions by means of radio-chemical methods, (4) physics with polarized high-energy neutrons, (5) physics with polarized high-energy deuterons, and (6) hypernucleus with high-energy heavy-ion beams. As a summary, new facilities (a new injector, a new beamline and a new experimental area) and physics programs with primary beams, proposed in this Report are themselves unique and valuable. Moreover, technical developments and physics outcomes stimulated with those new facilities are indispensable for future plans of the KEK-PS. (J.P.N.)

  2. Improvement of the 400 kV linac electron source of AmPS

    International Nuclear Information System (INIS)

    Kroes, F.B.; Beuzekom, M.G. van; Dobbe, N.J.; Es, J.T. van; Jansweijer, P.P.M.; Kruijer, A.H.; Luigjes, G.; Sluijk, T.G.B.

    1992-01-01

    An existing linac (MEA) injects electrons into the Amsterdam Pulse Stretcher (AmPS) ring. The linac's peak current increases from 20 to 80 mA. This requires the modification of the 400 kV low emittance gun. The fourfold increase of the peak current is obtained by doubling both the gun perveance (new gun part) and the pulsed extractor voltage. To obtain optimum beam quality over this increased current range, the hot deck electronics has been exchanged by a fast high voltage FET switching supply. A built-in microprocessor, coupled to the local computer by optical fibers, is used to monitor and control the gun parameters. The 5 kV gun extractor voltage pulse shape can be monitored by means of an analog fibre transducer with build in calibration. Finally, in order to improve the energy stability of the accelerated electrons, a serial electron-tube stabilizer was added to the 400 kV DC power supply. (K.A.) 4 refs.; 6 figs

  3. Using Growth Curves To Determine the Timing of the Booster Sessions.

    Science.gov (United States)

    Hennessy, Michael; Bolan, Gail A.; Hoxworth, Tamara; Iatesta, Michael; Rhodes, Fen; Zenilman, Jonathan M.

    1999-01-01

    Demonstrates an application of a method for using growth curves to determine the timing of booster sessions to reinforce the cognitive messages or behavior changes of interventions. Uses data from a multisite randomized experiment that compared three counseling and testing methods for preventing sexual disease transmission. Presents…

  4. The harmonic composition of the output voltage of a rectifier unit with a PWM voltage booster converter.

    OpenAIRE

    ПАНЧЕНКО, В В

    2015-01-01

    The author investigates a rectifier unit constructed on the basis of cascade connection of the main non-controlled m-pulse rectifier and PWM voltage booster converter. The research presents the analysis of the harmonic composition of the output voltage of a rectifier unit with a PWM voltage booster converter on completely controlled keys. The dependence of the relative harmonic amplitude on the commutation corner is defined. The estimation of a rectifier unit electromagnetic compatibility wit...

  5. Dipole power supply for National Synchrotron Light Source Booster upgrade

    International Nuclear Information System (INIS)

    Olsen, R.; Dabrowski, J.; Murray, J.

    1992-01-01

    The booster at the NSLS is being upgraded from .75 to 2 pulses per second. To accomplish this, new power supplies for the dipole, quadrupole, and sextupole magnets have been designed and are being constructed. This paper will outline the design of the dipole power supply and control system, and will present results obtained thus far

  6. Digital signal array processor for NSLS booster power supply upgrade

    International Nuclear Information System (INIS)

    Olsen, R.; Dabrowski, J.; Murray, J.

    1993-01-01

    The booster at the NSLS is being upgraded from 0.75 to 2 pulses per second. To accomplish this, new power supplied for the dipole, quadrupole, and sextupole have been installed. This paper will outline the design and function of the digital signal processor used as the primary control element in the power supply control system

  7. Processing and evaluation of the AGS Booster ultra-high vaccum system

    International Nuclear Information System (INIS)

    Hseuh, H.C.; Mapes, M.; Schnitzenbaumer, P.; Shen, B.; Sikora, R.; Stattel, P.

    1991-01-01

    The AGS Booster is a synchrotron for the acceleration of both protons and heavy ions. To minimize the beam loss due to charge exchange of the partially stripped, low Β very heavy ions with the residual gas molecules, pressure of low 10 -11 Torr is required for the 200 m booster ring. To achieve this ultra high vacuum, chemical cleaning, vacuum furnace degassing and insitu bake were employed for all chambers and beam components. Using these procedures, vacuums of low 10 -11 Torr have been routinely achieved during the testing of individual half cells and beam components, and during the commissioning of the vacuum sectors. In this paper, the design and layout of chambers, flanges and bakeout hardware is briefly described. The vacuum processing of different components and the results of bakeout and evaluation are summarized. The experience gained during the construction and commissioning of this ultra-high vacuum system is also given. 3 refs., 3 figs., 1 tab

  8. Superconducting linac booster for NSC Pelletron

    International Nuclear Information System (INIS)

    Roy, A.; Prakash, P.N.; Ajithkumar, B.P.; Ghosh, S.; Changrani, T.; Mehta, R.; Sarkar, A.; Muralidhar, S.; Dutt, R.N.; Kumar, M.; Shepard, K.W.; and others.

    1996-01-01

    The progress made in the heavy ion superconducting linac booster project for the Nuclear Science Centre Pelletron accelerator is overviewed. Prototypes of the accelerating structure have been fabricated at Argonne National Laboratory and undergone several diagnostic tests. In the first phase heavy ions up to mass 80 will be accelerated to energies above the Coulomb barrier and in the second phase the mass limit would be increased to 120. The subsystems of the project are the basic accelerating structures, the RF instrumentation and control, the cryogenic system and the beam optics. Preliminary designs for the buncher and linac cryostats have been made. Several prototypes of RF electronics and control modules have been fabricated and tested. (R.P.)

  9. Facile Synthesis of Mono-Dispersed Polystyrene (PS/Ag Composite Microspheres via Modified Chemical Reduction

    Directory of Open Access Journals (Sweden)

    Wen Zhu

    2013-12-01

    Full Text Available A modified method based on in situ chemical reduction was developed to prepare mono-dispersed polystyrene/silver (PS/Ag composite microspheres. In this approach; mono-dispersed PS microspheres were synthesized through dispersion polymerization using poly-vinylpyrrolidone (PVP as a dispersant at first. Then, poly-dopamine (PDA was fabricated to functionally modify the surfaces of PS microspheres. With the addition of [Ag(NH32]+ to the PS dispersion, [Ag(NH32]+ complex ions were absorbed and reduced to silver nanoparticles on the surfaces of PS-PDA microspheres to form PS/Ag composite microspheres. PVP acted both as a solvent of the metallic precursor and as a reducing agent. PDA also acted both as a chemical protocol to immobilize the silver nanoparticles at the PS surface and as a reducing agent. Therefore, no additional reducing agents were needed. The resulting composite microspheres were characterized by TEM, field emission scanning electron microscopy (FESEM, energy-dispersive X-ray spectroscopy (EDS, XRD, UV-Vis and surface-enhanced Raman spectroscopy (SERS. The results showed that Ag nanoparticles (NPs were homogeneously immobilized onto the PS microspheres’ surface in the presence of PDA and PVP. PS/Ag composite microspheres were well formed with a uniform and compact shell layer and were adjustable in terms of their optical property.

  10. RF field control for Kaon Factory booster cavities

    International Nuclear Information System (INIS)

    Craig, S.T.; de Jong, M.S.

    1992-08-01

    A conceptual design is developed for control of the Kaon Factory booster rf accelerating fields. This design addresses control of cavity: tuning, voltage amplitude, and voltage phase angle. Time-domain simulations were developed to evaluate the proposed controllers. These simulations indicate that adequate tuning performance can be obtained with the combination of adaptive feed forward and proportional feedback control. Voltage amplitude and voltage phase can be adequately controlled using non-adaptive feed forward and proportional feedback control. (Author) (figs., tabs.)

  11. Diesel Combustion and Emission Using High Boost and High Injection Pressure in a Single Cylinder Engine

    Science.gov (United States)

    Aoyagi, Yuzo; Kunishima, Eiji; Asaumi, Yasuo; Aihara, Yoshiaki; Odaka, Matsuo; Goto, Yuichi

    Heavy-duty diesel engines have adopted numerous technologies for clean emissions and low fuel consumption. Some are direct fuel injection combined with high injection pressure and adequate in-cylinder air motion, turbo-intercooler systems, and strong steel pistons. Using these technologies, diesel engines have achieved an extremely low CO2 emission as a prime mover. However, heavy-duty diesel engines with even lower NOx and PM emission levels are anticipated. This study achieved high-boost and lean diesel combustion using a single cylinder engine that provides good engine performance and clean exhaust emission. The experiment was done under conditions of intake air quantity up to five times that of a naturally aspirated (NA) engine and 200MPa injection pressure. The adopted pressure booster is an external supercharger that can control intake air temperature. In this engine, the maximum cylinder pressure was increased and new technologies were adopted, including a monotherm piston for endurance of Pmax =30MPa. Moreover, every engine part is newly designed. As the boost pressure increases, the rate of heat release resembles the injection rate and becomes sharper. The combustion and brake thermal efficiency are improved. This high boost and lean diesel combustion creates little smoke; ISCO and ISTHC without the ISNOx increase. It also yields good thermal efficiency.

  12. Kultuur isiksuse psühholoogiat ei mõjuta / Tiit Kändler

    Index Scriptorium Estoniae

    Kändler, Tiit, 1948-

    2010-01-01

    Psühholoogia uuemate andmete kohaselt ei sõltu indiviidi seadumus kultuurist, soost, vanusest, haridusest. Eesti psühholoogide Jüri Alliku ja Ann Realo osalusel ajakirjas "Journal Personality and Social Psychology" ilmunud artiklist

  13. Kultuur isiksuse psühholoogiat ei mõjuta / Tiit Kändler

    Index Scriptorium Estoniae

    Kändler, Tiit, 1948-

    2005-01-01

    Psühholoogia uuemate andmete kohaselt ei sõltu indiviidi seadumus kultuurist, soost, vanusest, haridusest. Eesti psühholoogide Jüri Alliku ja Anu Realo osalusel ajakirjas "Journal Personality and Social Psychology" ilmunud artiklist

  14. File list: His.PSC.10.AllAg.iPS_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.PSC.10.AllAg.iPS_cells hg19 Histone Pluripotent stem cell iPS cells SRX110016,S...315,SRX381309 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/His.PSC.10.AllAg.iPS_cells.bed ...

  15. File list: His.PSC.05.AllAg.iPS_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.PSC.05.AllAg.iPS_cells hg19 Histone Pluripotent stem cell iPS cells SRX317576,S...077,SRX317607 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/His.PSC.05.AllAg.iPS_cells.bed ...

  16. File list: Oth.PSC.05.AllAg.iPS_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.PSC.05.AllAg.iPS_cells mm9 TFs and others Pluripotent stem cell iPS cells SRX65...RX146524 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Oth.PSC.05.AllAg.iPS_cells.bed ...

  17. File list: His.PSC.20.AllAg.iPS_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.PSC.20.AllAg.iPS_cells hg19 Histone Pluripotent stem cell iPS cells SRX110015,S...315,SRX381309 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/His.PSC.20.AllAg.iPS_cells.bed ...

  18. Comparison of molecular species of various transphosphatidylated phosphatidylserine (PS) with bovine cortex PS by mass spectrometry

    NARCIS (Netherlands)

    Chen, S.; Li, K.W.

    2008-01-01

    The exogenous introduction of a molecular species mixture of bovine cortex phosphatidylserine (BC-PS) has been claimed to improve memory function in subjects suffering from age-associated memory impairment and dementia. However, it has been also reported that oral administration of another molecular

  19. Thermodynamic and chemical parameters of the exhaust effluents from the HARPOON booster motor

    Science.gov (United States)

    Stephens, J. B.; Goldford, A. I.

    1978-01-01

    The exhaust products from the Harpoon booster motors were analyzed using both thermodynamic analysis and finite-rate chemistry. The resulting constituents are presented together with a discussion of the techniques employed.

  20. Hydrogen sulfide booster compressors for HWP Manuguru - oil reclamation study - BHEL experience (Paper No. 5.2)

    International Nuclear Information System (INIS)

    Godbole, A.; Santanam, N.; Murthy, T.S.R.

    1992-01-01

    BHEL undertook the development of hydrogen sulphide booster compressor with a view to indigenise this most critical equipment in a heavy water plant. Throughout the design, manufacture and shop testing of these booster compressors BHEL had close interaction with Heavy Water Board. This paper describes the problems faced during commissioning of compressors at KCR -Manuguru such as deficiencies in the sizing of LP seal oil drain, development of a process for reclamation of oil and development of alternate sealing arrangement, etc. (author). 1 tab., 4 figs

  1. The superconducting linac booster at the ANU

    International Nuclear Information System (INIS)

    Weisser, D.C.

    1995-02-01

    This report outlines the progress of the installation of the superconducting Linac booster at the Australian National University. The Linac is based upon four modules, three of which contain three split-loop resonators. The fourth cryostat was intended to be a superbuncher and so houses only one resonator. The first stage of Linac operation will employ only three modules with 2 MV/m from each resonator. It is expected that the implementation of all nine modules, in subsequent stages, would boost beams by 18 MV/q. The project has fostered productive international collaboration between UK and Australian scientists. 1 tab., 6 figs

  2. Chemical resistance of core-shell particles (PS/PMMA) polymerized by seeded suspension

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Luiz Fernando Belchior; Machado, Ricardo Antonio Francisco, E-mail: ricardo.machado@ufsc.br [Universidade Federal de Santa Catarina (UFSC), Florianopolis, SC (Brazil). Departamento de Engenharia de Materiais; Gonçalves, Odinei Hess [Universidade Técnológica Federal do Paraná(UTFPR), Campo Mourão, PR (Brazil); Marangoni, Cintia [Universidade Federal de Santa Catarina (UFSC), Blumenau, SC (Brazil); Motz, Günter [Lehrstuhl Keramische Werkstoffe, Universität Bayreuth (Germany)

    2017-07-01

    Core-shell particles were produced on seeded suspension polymerization by using polystyrene (PS) as polymer core, or seed, and methyl methacrylate (MMA) as the shell forming monomer. Two synthesis routes were evaluated by varying the PS seed conversion before MMA addition. The main purpose of this work was to investigate the influence of synthesis routes on the morphology and chemical resistance of the resulting particles. {sup 1}H NMR spectroscopy showed that the use of PS seeds with lower conversion led to the formation of higher amount of poly(styrene-co-MMA). The copolymer acted as a compatibilizer, decreasing the interfacial energy between both homopolymers. As a consequence, a larger amount of reduced PMMA cluster were formed, as was revealed by TEM measurements. Samples in this system showed enhanced resistance to cyclohexane attack compared with pure PS, with a PS extraction of only 37% after 54 hours test. (author)

  3. Chemical resistance of core-shell particles (PS/PMMA polymerized by seeded suspension

    Directory of Open Access Journals (Sweden)

    Luiz Fernando Belchior Ribeiro

    2017-09-01

    Full Text Available Abstract Core-shell particles were produced on seeded suspension polymerization by using polystyrene (PS as polymer core, or seed, and methyl methacrylate (MMA as the shell forming monomer. Two synthesis routes were evaluated by varying the PS seed conversion before MMA addition. The main purpose of this work was to investigate the influence of synthesis routes on the morphology and chemical resistance of the resulting particles. 1H NMR spectroscopy showed that the use of PS seeds with lower conversion led to the formation of higher amount of poly(styrene-co-MMA. The copolymer acted as a compatibilizer, decreasing the interfacial energy between both homopolymers. As a consequence, a larger amount of reduced PMMA cluster were formed, as was revealed by TEM measurements. Samples in this system showed enhanced resistance to cyclohexane attack compared with pure PS, with a PS extraction of only 37% after 54 hours test.

  4. Direct Comparison of Immunogenicity Induced by 10- or 13-Valent Pneumococcal Conjugate Vaccine around the 11-Month Booster in Dutch Infants.

    Directory of Open Access Journals (Sweden)

    Alienke J Wijmenga-Monsuur

    Full Text Available Since 2009/10, a 10- and a 13-valent pneumococcal conjugate vaccine (PCV are available, but only the 10-valent vaccine is now being used for the children in the Netherlands. As the vaccines differ in number of serotypes, antigen concentration, and carrier proteins this study was designed to directly compare quantity and quality of the antibody responses induced by PCV10 and PCV13 before and after the 11-month booster.Dutch infants (n = 132 were immunized with either PCV10 or PCV13 and DTaP-IPV-Hib-HepB at the age of 2, 3, 4 and 11 months. Blood samples were collected pre-booster and post-booster at one week and one month post-booster for quantitative and qualitative immunogenicity against 13 pneumococcal serotypes, as well as quantitative immunogenicity against diphtheria, tetanus, pertussis and Haemophilus influenzae type b. We compared immunogenicity induced by PCV13 and PCV10 for their ten shared serotypes.One month post-booster, pneumococcal serotype-specific IgG geometric mean concentrations (GMCs for the PCV13 group were higher compared with the PCV10 group for six serotypes, although avidity was lower. Serotype 19F showed the most distinct difference in IgG and, in contrast to other serotypes, its avidity was higher in the PCV13 group. One week post-booster, opsonophagocytosis for serotype 19F did not differ significantly between the PCV10- and the PCV13 group.Both PCV10 and PCV13 were immunogenic and induced a booster response. Compared to the PCV10 group, the PCV13 group showed higher levels for serotype 19F GMCs and avidity, pre- as well as post-booster, although opsonophagocytosis did not differ significantly between groups. In our study, avidity is not correlated to opsonophagocytotic activity (OPA and correlations between IgG and OPA differ per serotype. Therefore, besides assays to determine IgG GMCs, assays to detect opsonophagocytotic activity, i.e., the actual killing of the pneumococcus, are important for PCV evaluation. How

  5. File list: ALL.PSC.50.AllAg.iPS_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.PSC.50.AllAg.iPS_cells mm9 All antigens Pluripotent stem cell iPS cells SRX9773...1,SRX035985,SRX1090869 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/ALL.PSC.50.AllAg.iPS_cells.bed ...

  6. File list: ALL.PSC.50.AllAg.iPS_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.PSC.50.AllAg.iPS_cells hg19 All antigens Pluripotent stem cell iPS cells SRX088...16,SRX189400,SRX189399 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/ALL.PSC.50.AllAg.iPS_cells.bed ...

  7. File list: ALL.PSC.20.AllAg.iPS_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.PSC.20.AllAg.iPS_cells hg19 All antigens Pluripotent stem cell iPS cells SRX088...27,SRX189400,SRX189399 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/ALL.PSC.20.AllAg.iPS_cells.bed ...

  8. File list: ALL.PSC.20.AllAg.iPS_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.PSC.20.AllAg.iPS_cells mm9 All antigens Pluripotent stem cell iPS cells SRX9773...30,SRX146522,SRX146547 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/ALL.PSC.20.AllAg.iPS_cells.bed ...

  9. File list: Pol.PSC.05.AllAg.iPS_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.PSC.05.AllAg.iPS_cells mm9 RNA polymerase Pluripotent stem cell iPS cells SRX97...7435,SRX027462,SRX977434 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Pol.PSC.05.AllAg.iPS_cells.bed ...

  10. Space Shuttle solid rocket booster

    Science.gov (United States)

    Hardy, G. B.

    1979-01-01

    Details of the design, operation, testing and recovery procedures of the reusable solid rocket boosters (SRB) are given. Using a composite PBAN propellant, they will provide the primary thrust (six million pounds maximum at 20 s after ignition) within a 3 g acceleration constraint, as well as thrust vector control for the Space Shuttle. The drogues were tested to a load of 305,000 pounds, and the main parachutes to 205,000. Insulation in the solid rocket motor (SRM) will be provided by asbestos-silica dioxide filled acrylonitrile butadiene rubber ('asbestos filled NBR') except in high erosion areas (principally in the aft dome), where a carbon-filled ethylene propylene diene monomer-neopreme rubber will be utilized. Furthermore, twenty uses for the SRM nozzle will be allowed by its ablative materials, which are principally carbon cloth and silica cloth phenolics.

  11. 200 ps FWHM and 100 MHz repetition rate ultrafast gated camera for optical medical functional imaging

    Science.gov (United States)

    Uhring, Wilfried; Poulet, Patrick; Hanselmann, Walter; Glazenborg, René; Zint, Virginie; Nouizi, Farouk; Dubois, Benoit; Hirschi, Werner

    2012-04-01

    The paper describes the realization of a complete optical imaging device to clinical applications like brain functional imaging by time-resolved, spectroscopic diffuse optical tomography. The entire instrument is assembled in a unique setup that includes a light source, an ultrafast time-gated intensified camera and all the electronic control units. The light source is composed of four near infrared laser diodes driven by a nanosecond electrical pulse generator working in a sequential mode at a repetition rate of 100 MHz. The resulting light pulses, at four wavelengths, are less than 80 ps FWHM. They are injected in a four-furcated optical fiber ended with a frontal light distributor to obtain a uniform illumination spot directed towards the head of the patient. Photons back-scattered by the subject are detected by the intensified CCD camera; there are resolved according to their time of flight inside the head. The very core of the intensified camera system is the image intensifier tube and its associated electrical pulse generator. The ultrafast generator produces 50 V pulses, at a repetition rate of 100 MHz and a width corresponding to the 200 ps requested gate. The photocathode and the Micro-Channel-Plate of the intensifier have been specially designed to enhance the electromagnetic wave propagation and reduce the power loss and heat that are prejudicial to the quality of the image. The whole instrumentation system is controlled by an FPGA based module. The timing of the light pulses and the photocathode gating is precisely adjustable with a step of 9 ps. All the acquisition parameters are configurable via software through an USB plug and the image data are transferred to a PC via an Ethernet link. The compactness of the device makes it a perfect device for bedside clinical applications.

  12. CFD Assessment of Forward Booster Separation Motor Ignition Overpressure on ET XT 718 Ice/Frost Ramp

    Science.gov (United States)

    Tejnil, Edward; Rogers, Stuart E.

    2012-01-01

    Computational fluid dynamics assessment of the forward booster separation motor ignition over-pressure was performed on the space shuttle external tank X(sub T) 718 ice/frost ramp using the flow solver OVERFLOW. The main objective of this study was the investigation of the over-pressure during solid rocket booster separation and its affect on the local pressure and air-load environments. Delta pressure and plume impingement were investigated as a possible contributing factor to the cause of the debris loss on shuttle missions STS-125 and STS-127. A simplified computational model of the Space Shuttle Launch Vehicle was developed consisting of just the external tank and the solid rocket boosters with separation motor nozzles and plumes. The simplified model was validated by comparison to full fidelity computational model of the Space Shuttle without the separation motors. Quasi steady-state plume solutions were used to calibrate the thrust of the separation motors. Time-accurate simulations of the firing of the booster-separation motors were performed. Parametric studies of the time-step size and the number of sub-iterations were used to find the best converged solution. The computed solutions were compared to previous OVERFLOW steady-state runs of the separation motors with reaction control system jets and to ground test data. The results indicated that delta pressure from the overpressure was small and within design limits, and thus was unlikely to have contributed to the foam losses.

  13. Booster: Development of a Toolbox for Triage of a Large Group of Individuals Exposed to Radioactive Material

    International Nuclear Information System (INIS)

    Schoepff, V.; Carrel, F.; Gmar, M.; Lemaire, H.; Carvajal, F.; Perez-Llopis, I.; Gaboriau, D.-C.; Morrison, C.-G.; Almasi, I.; Szabo, S.; Kovacs, A; Szeles, E.; Amgarou, K.; Menaa, N.; Morat, L.; Testard, I.; Ugolin, N.; Viau, M.; Becker, F.; Raskob, W.; Trybushnyi, D.; Vincze, A.

    2013-06-01

    The effective management of an event involving the exposure of a large number of people to radioactive material requires a mechanism for fast triage of exposed people. BOOSTER is a project founded by the European Union under the Seventh Framework Programme, addressing this requirement. It is a capability project designed to provide an integrated system which could easily be deployed and used. For this purpose, the BOOSTER consortium, relying on the expertise of seven members, researches and develops new approaches to allow an effective and fast management of most kind of nuclear threats. BOOSTER System was designed to help first responders mitigating the crisis by providing the necessary information to quickly assess the radiological situation, to support triage staff in performing an efficient and fast categorization of the potentially affected victims, and to give medical staff crucial information for further treatment at medium or long term post-accident. (authors)

  14. Shallow PS-logging by high frequency wave; Koshuha wo mochiita senbu PS kenso

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, A; Miyazawa, M; Azuma, H [OYO Corp., Tokyo (Japan)

    1996-05-01

    This paper describes the following matters on down-hole PS logging in shallow subsurface. Determining an elastic wave velocity structure in shallow subsurface with high accuracy by using down-hole PS logging requires reduction of errors in reading travel time. Therefore, a high-frequency vibration source was fabricated with an objective to raise frequencies of waves used for the measurement. Measurements were made on two holes, A and B, at a measurement interval of 0.5 m, whereas at the hole A a measurement was performed simultaneously by using a normal type (low-frequency) vibration source. A spectral analysis on the waveform record revealed that the frequencies with each vibration source were 127 Hz and 27 Hz for the hole A, 115 Hz for the hole B, and the S/N ratio was all the same for both holes. When the high-frequency vibration source was used, the velocity was determined at accuracy of 5% over the whole length of the shallow section. When the low-frequency vibration source was used, sections with the velocity determining error greater than 5% were found, and it was not possible to derive the velocity structure in the shallow subsurface in fine segments. 3 refs., 8 figs., 2 tabs.

  15. Community awareness and predictors of uptake of pertussis booster vaccine in South Australian adults.

    Science.gov (United States)

    Clarke, Michelle; Thomas, Natalie; Giles, Lynne; Marshall, Helen

    2015-12-16

    Pertussis is a highly virulent vaccine preventable disease that remains a global challenge. This study aimed to assess community knowledge of pertussis infection as well as awareness and uptake of adult pertussis booster vaccine. A cross-sectional survey was conducted of randomly selected households in South Australia by Computer Assisted Telephone Interviews in 2011. Survey data were weighted to the age, gender and geographical area profile of the population. From 3124 randomly sampled contactable households, 1967 interviews were conducted (participation rate 63%) with individuals aged 18-93 years, including 608 parents of children aged pertussis (whooping cough) and 18% reported that a household member had previously contracted whooping cough infection. Most respondents considered whooping cough to be highly contagious (73%) and severe for infants (89%). Over half (51%) of those surveyed were aware that family members commonly transmit pertussis to infants. Despite high knowledge, pertussis vaccine uptake was low, with only 10% of respondents reporting pertussis vaccination in the previous five years. Whilst 61% of respondents were aware of the availability of an adult pertussis booster vaccine, only 8% (n=154) reported their Family Physician had discussed it with them. If provided free, 77% agreed that they would be more likely to accept a booster pertussis vaccination. Independent predictors of recent pertussis vaccination included higher education, larger household size, perception of greater disease severity for infants and discussion with a Family Physician about pertussis vaccination. Whilst knowledge regarding transmission and severity of Bordetella pertussis was high, uptake of pertussis vaccination for adults is remarkably low amongst the South Australian community. Improved awareness regarding the availability of a booster pertussis vaccine through Family Physicians and/or provision of funded pertussis vaccination for adults has the potential to improve

  16. File list: ALL.PSC.10.AllAg.iPS_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.PSC.10.AllAg.iPS_cells mm9 All antigens Pluripotent stem cell iPS cells SRX9774...30,SRX146524,SRX146547,SRX146522 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/ALL.PSC.10.AllAg.iPS_cells.bed ...

  17. EDH 'Millionaire' in PS Division

    CERN Multimedia

    2001-01-01

    Christmas cheer! Left to right: Gerard Lobeau receives a bottle of Champagne from Derek Mathieson and Jurgen De Jonghe in recognition of EDH's millionth document. At 14:33 on Monday 3 December a technician in PS division, Gerard Lobeau, unwittingly became part of an important event in the life of CERN's Electronic Document Handling system (EDH). While ordering some pieces of aluminum for one of the PS's 10Mhz RF cavities, he created EDH document number 1,000,000. To celebrate the event Derek Mathieson (EDH Project Leader) and Jurgen De Jonghe (Original EDH Project Leader) presented Mr Lobeau with a bottle of champagne. As with 93% of material requests, Mr Lobeau's order was delivered within 24 hours. 'I usually never win anything' said Mr Lobeau as he accepted his prize, 'I initially though there may have been a problem with EDH when the document number had so many zeros in it, and was then surprised to get a phone call from you a few minutes later.' The EDH team had been monitoring the EDH document number ...

  18. Characterizing Lithospheric Thickness in Australia using Ps and Sp Scattered Waves

    Science.gov (United States)

    Ford, H. A.; Fischer, K. M.; Rychert, C. A.

    2008-12-01

    The purpose of this study is to constrain the morphology of the lithosphere-asthenosphere boundary throughout Australia using scattered waves. Prior surface wave studies have shown a correlation between lithospheric thickness and the three primary geologic provinces of Australia, with the shallowest lithosphere located beneath the Phanerozoic province to the east, and the thicker lithosphere located beneath the Proterozoic and Archean regions. To determine lithospheric thickness, waveform data from twenty permanent broadband stations spanning mainland Australia and the island of Tasmania were analyzed using Ps and Sp migration techniques. Waveform selection for each station was based on epicentral distance (35° to 80° for Ps and 55° to 80° for Sp), and event depth (no greater than 300 km for Sp). For both Ps and Sp a simultaneous deconvolution was performed on the data for each of the twenty stations, and the resulting receiver function for each station was migrated to depth. Data were binned with epicentral distance to differentiate direct discontinuity phases from crustal reverberations (for Ps) and other teleseismic arrivals (for Sp). Early results in both Ps and Sp show a clear Moho discontinuity at most stations in addition to sharp, strong crustal reverberations seen in many of the Ps images. In the eastern Phanerozoic province, a strong negative phase at 100-105 km is evident in Ps for stations CAN and EIDS. The negative phase lies within a depth range that corresponds to the negative velocity gradient between fast lithosphere and slow asthenosphere imaged by surface waves. We therefore think that it is the lithosphere- asthenosphere boundary. On the island of Tasmania, a negative phase at 70-75 km in Ps images at stations TAU and MOO also appears to be the lithosphere-asthenosphere boundary. In the Proterozoic and Archean regions of the Australian continent, initial results for both Ps and Sp migration indicate clear crustal phases, but significantly

  19. Analüütilised voolud psühholoogias ja nende rakendamine pedagoogikas / Aleksander Elango

    Index Scriptorium Estoniae

    Elango, Aleksander, 1902-2004

    2001-01-01

    Analüütise psühholoogia kolm koolkonda - S.Freudì koolkond e. päris-psühhoanalüüs, A.Adlerì koolkond e. individuaalpsühholoogia ja C.G.Jungì psühhoanalüüsi ja individuaalpsühholoogia sünteesi luua püüdev koolkond. Analüütise psühholoogia koolkondade ja pedagoogika suhetest

  20. Human iPS Cell-Derived Germ Cells: Current Status and Clinical Potential

    Directory of Open Access Journals (Sweden)

    Tetsuya Ishii

    2014-10-01

    Full Text Available Recently, fertile spermatozoa and oocytes were generated from mouse induced pluripotent (iPS cells using a combined in vitro and in vivo induction system. With regard to germ cell induction from human iPS cells, progress has been made particularly in the male germline, demonstrating in vitro generation of haploid, round spermatids. Although iPS-derived germ cells are expected to be developed to yield a form of assisted reproductive technology (ART that can address unmet reproductive needs, genetic and/or epigenetic instabilities abound in iPS cell generation and germ cell induction. In addition, there is still room to improve the induction protocol in the female germline. However, rapid advances in stem cell research are likely to make such obstacles surmountable, potentially translating induced germ cells into the clinical setting in the immediate future. This review examines the current status of the induction of germ cells from human iPS cells and discusses the clinical potential, as well as future directions.

  1. (PS)2: protein structure prediction server version 3.0.

    Science.gov (United States)

    Huang, Tsun-Tsao; Hwang, Jenn-Kang; Chen, Chu-Huang; Chu, Chih-Sheng; Lee, Chi-Wen; Chen, Chih-Chieh

    2015-07-01

    Protein complexes are involved in many biological processes. Examining coupling between subunits of a complex would be useful to understand the molecular basis of protein function. Here, our updated (PS)(2) web server predicts the three-dimensional structures of protein complexes based on comparative modeling; furthermore, this server examines the coupling between subunits of the predicted complex by combining structural and evolutionary considerations. The predicted complex structure could be indicated and visualized by Java-based 3D graphics viewers and the structural and evolutionary profiles are shown and compared chain-by-chain. For each subunit, considerations with or without the packing contribution of other subunits cause the differences in similarities between structural and evolutionary profiles, and these differences imply which form, complex or monomeric, is preferred in the biological condition for the subunit. We believe that the (PS)(2) server would be a useful tool for biologists who are interested not only in the structures of protein complexes but also in the coupling between subunits of the complexes. The (PS)(2) is freely available at http://ps2v3.life.nctu.edu.tw/. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  2. Yellow Fever Vaccine Booster Doses: Recommendations of the Advisory Committee on Immunization Practices, 2015.

    Science.gov (United States)

    Staples, J Erin; Bocchini, Joseph A; Rubin, Lorry; Fischer, Marc

    2015-06-19

    On February 26, 2015, the Advisory Committee on Immunization Practices (ACIP) voted that a single primary dose of yellow fever vaccine provides long-lasting protection and is adequate for most travelers. ACIP also approved recommendations for at-risk laboratory personnel and certain travelers to receive additional doses of yellow fever vaccine (Box). The ACIP Japanese Encephalitis and Yellow Fever Vaccines Workgroup evaluated published and unpublished data on yellow fever vaccine immunogenicity and safety. The evidence for benefits and risks associated with yellow fever vaccine booster doses was evaluated using the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) framework. This report summarizes the evidence considered by ACIP and provides the updated recommendations for yellow fever vaccine booster doses.

  3. A paralogous decoy protects Phytophthora sojae apoplastic effector PsXEG1 from a host inhibitor.

    Science.gov (United States)

    Ma, Zhenchuan; Zhu, Lin; Song, Tianqiao; Wang, Yang; Zhang, Qi; Xia, Yeqiang; Qiu, Min; Lin, Yachun; Li, Haiyang; Kong, Liang; Fang, Yufeng; Ye, Wenwu; Wang, Yan; Dong, Suomeng; Zheng, Xiaobo; Tyler, Brett M; Wang, Yuanchao

    2017-02-17

    The extracellular space (apoplast) of plant tissue represents a critical battleground between plants and attacking microbes. Here we show that a pathogen-secreted apoplastic xyloglucan-specific endoglucanase, PsXEG1, is a focus of this struggle in the Phytophthora sojae -soybean interaction. We show that soybean produces an apoplastic glucanase inhibitor protein, GmGIP1, that binds to PsXEG1 to block its contribution to virulence. P. sojae , however, secretes a paralogous PsXEG1-like protein, PsXLP1, that has lost enzyme activity but binds to GmGIP1 more tightly than does PsXEG1, thus freeing PsXEG1 to support P. sojae infection. The gene pair encoding PsXEG1 and PsXLP1 is conserved in many Phytophthora species, and the P. parasitica orthologs PpXEG1 and PpXLP1 have similar functions. Thus, this apoplastic decoy strategy may be widely used in Phytophthora pathosystems. Copyright © 2017, American Association for the Advancement of Science.

  4. Sub One-Hundred-PS Pyroelectric Detector Research and Evaluation Program at LASL

    International Nuclear Information System (INIS)

    McLellan, E.J.; Stotlar, S.C.

    1978-01-01

    Preliminary devices have been designed and evaluated with 1 ns and 90 ps FWHM CO 2 laser pulses. Good agreement between calculated and measured values of falltime and voltage responsivity has been obtained. The female SMA to male BNC connector appears to be the most desirable easily available package for sub-one-hundred ps CO 2 laser pulses. A new detector with an expected risetime of 13 ps has been designed

  5. Niobium quarter-wave cavity for the New Delhi booster linac

    International Nuclear Information System (INIS)

    Shepard, K.W.; Roy, A.; Potukuchi, P.N.

    1997-01-01

    This paper reports the completion of development of a 97 Mhz niobium coaxial quarter-wave cavity to be used in a booster linac for the New Delhi 16UD pellatron electrostatic accelerator. A prototype cavity, which incorporates a niobium-bellows tuning device, has been completed and operated at 4.2 K at accelerating gradients above 4 MV/m for extended periods of time

  6. Niobium quarter-wave cavity for the New Delhi booster linac

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, K.W. [Argonne National Lab., IL (United States); Roy, A.; Potukuchi, P.N. [Nuclear Science Centre, New Delhi (India)

    1997-09-01

    This paper reports the completion of development of a 97 Mhz niobium coaxial quarter-wave cavity to be used in a booster linac for the New Delhi 16UD pellatron electrostatic accelerator. A prototype cavity, which incorporates a niobium-bellows tuning device, has been completed and operated at 4.2 K at accelerating gradients above 4 MV/m for extended periods of time.

  7. Baseline immunity to diphtheria and immunologic response after booster vaccination with reduced diphtheria and tetanus toxoid vaccine in Thai health care workers.

    Science.gov (United States)

    Wiboonchutikul, Surasak; Manosuthi, Weerawat; Sangsajja, Chariya; Thientong, Varaporn; Likanonsakul, Sirirat; Srisopha, Somkid; Termvises, Patamavadee; Rujitip, Jitlada; Loiusirirotchanakul, Suda; Puthavathana, Pilaipan

    2014-07-01

    A prospective study to evaluate immune status against diphtheria and immunologic response after tetanus-diphtheria (Td) booster vaccination was conducted in 250 Thai health care workers (HCWs). A protective antibody was found in 89.2% of the HCWs (95% confidence interval [CI], 83.3%-91.5%) before receipt of the Td booster vaccination, compared with 97.2% (95% CI, 95.1%-99.3%) after receipt of the first dose of booster (P diphtheria increased from 0.39 IU/mL (95% CI, 0.35-0.44 IU/mL) before the Td booster vaccination to 1.20 IU/mL (95% CI, 1.12-1.29 IU/mL) after the vaccination (P diphtheria, which still circulates in Thailand. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  8. Design of the AGS Booster beam position monitor system

    International Nuclear Information System (INIS)

    Beadle, E.; Brennan, J.M.; Ciardullo, D.J.; Savino, J.; Stanziani, V.; Thomas, R.; Van Zwienen, W.; Witkover, R.L.; Schulte, E.

    1989-01-01

    The AGS Booster beam position monitor system must cover a wide range of beam intensity and bunch length for proton and heavy ion acceleration. The detector is designed to maintain 0.1 mm local tolerance following 300 degree C bakeout. The electronics will be located in the tunnel, communicating via fiber optic links to avoid ground loops. The design will be described and test results for prototype units presented. 5 refs., 4 figs

  9. MD210 Note: Creation of Hollow Bunches in the PSB

    CERN Document Server

    Oeftiger, Adrian; Findlay, Alan James; Hancock, Steven; Rumolo, Giovanni; CERN. Geneva. ATS Department

    2016-01-01

    MD210 aims for the creation of longitudinally hollow bunches in the CERN PS Booster. The first three sessions have been carried out using the radial loop feedback system in order to drive the beam on a dipolar parametric resonance (instead of the phase loop). It has been found that the damping by the phase loop inhibits the excitation of the resonance to a major extent. The hollow distributions generated under these circumstances fail to reach a satisfying bunching factor. Nonetheless, proving the principally successful application of this technique to the PS Booster promises good results once the phase loop system supports trim functions. The approach, actions and detailed results of the first three MD sessions are presented in this paper.

  10. Perceptions of Community Health Workers (CHWs/PS in the U.S.-Mexico Border HEART CVD Study

    Directory of Open Access Journals (Sweden)

    Hector G. Balcazar

    2014-02-01

    Full Text Available Although prior research has shown that Community Health Workers/Promotores de Salud (CHW/PS can facilitate access to care, little is known about how CHW/PS are perceived in their community. The current study reports the findings of a randomized telephone survey conducted in a high-risk urban community environment along the U.S.-Mexico border. In preparation for a community-based CHW/PS intervention called the HEART ecological study, the survey aimed to assess perceptions of CHW/PS, availability and utilization of community resources (recreational and nutrition related and health behaviors and intentions. A total of 7,155 calls were placed to complete 444 surveys in three zip codes in El Paso, Texas. Results showed that participants felt that healthful community resources were available, but utilization was low and variable: 35% reported going to a park, 20% reported having taken a health class, few reported using a gym (12%, recreation center (8%, or YMCA/YWCA (0.9%. Awareness and utilization of CHW/PS services were low: 20% of respondents had heard of CHW/PS, with 8% reporting previous exposure to CHW/PS services. Upon review of a definition of CHW/PS, respondents expressed positive views of CHW/PS and their value in the healthcare system. Respondents who had previous contact with a CHW/PS reported a significantly more positive perception of the usefulness of CHW/PS (p = 0.006, were more likely to see CHW/PS as an important link between providers and patients (p = 0.008, and were more likely to ask a CHW/PS for help (p = 0.009. Participants who utilized CHW/PS services also had significantly healthier intentions to reduce fast food intake. Future research is needed to evaluate if CHW/PS can facilitate utilization of available community resources such as recreational facilities among Hispanic border residents at risk for CVD.

  11. Long-Term Safety and Immunogenicity of a Tetravalent Live-Attenuated Dengue Vaccine and Evaluation of a Booster Dose Administered to Healthy Thai Children.

    Science.gov (United States)

    Watanaveeradej, Veerachai; Simasathien, Sriluck; Mammen, Mammen P; Nisalak, Ananda; Tournay, Elodie; Kerdpanich, Phirangkul; Samakoses, Rudiwilai; Putnak, Robert J; Gibbons, Robert V; Yoon, In-Kyu; Jarman, Richard G; De La Barrera, Rafael; Moris, Philippe; Eckels, Kenneth H; Thomas, Stephen J; Innis, Bruce L

    2016-06-01

    We evaluated the safety and immunogenicity of two doses of a live-attenuated, tetravalent dengue virus vaccine (F17/Pre formulation) and a booster dose in a dengue endemic setting in two studies. Seven children (7- to 8-year-olds) were followed for 1 year after dose 2 and then given a booster dose (F17/Pre formulation), and followed for four more years (Child study). In the Infant study, 49 2-year-olds, vaccinated as infants, were followed for approximately 3.5 years after dose 2 and then given a booster dose (F17) and followed for one additional year. Two clinically notable events were observed, both in dengue vaccine recipients in the Infant study: 1 case of dengue approximately 2.7 years after dose 2 and 1 case of suspected dengue after booster vaccinations. The booster vaccinations had a favorable safety profile in terms of reactogenicity and adverse events reported during the 1-month follow-up periods. No vaccine-related serious adverse events were reported during the studies. Neutralizing antibodies against dengue viruses 1-4 waned during the 1-3 years before boosting, which elicited a short-lived booster response but did not provide a long-lived, multivalent antibody response in most subjects. Overall, this candidate vaccine did not elicit a durable humoral immune response. © The American Society of Tropical Medicine and Hygiene.

  12. Pulse radiolysis based on a femtosecond electron beam and a femtosecond laser light with double-pulse injection technique

    International Nuclear Information System (INIS)

    Yang Jinfeng; Kondoh, Takafumi; Kozawa, Takahiro; Yoshida, Youichi; Tagawa, Seiichi

    2006-01-01

    A new pulse radiolysis system based on a femtosecond electron beam and a femtosecond laser light with oblique double-pulse injection was developed for studying ultrafast chemical kinetics and primary processes of radiation chemistry. The time resolution of 5.2 ps was obtained by measuring transient absorption kinetics of hydrated electrons in water. The optical density of hydrated electrons was measured as a function of the electron charge. The data indicate that the double-laser-pulse injection technique was a powerful tool for observing the transient absorptions with a good signal to noise ratio in pulse radiolysis

  13. Update on Risk Reduction Activities for a Liquid Advanced Booster for NASA's Space Launch System

    Science.gov (United States)

    Crocker, Andrew M.; Doering, Kimberly B; Meadows, Robert G.; Lariviere, Brian W.; Graham, Jerry B.

    2015-01-01

    The stated goals of NASA's Research Announcement for the Space Launch System (SLS) Advanced Booster Engineering Demonstration and/or Risk Reduction (ABEDRR) are to reduce risks leading to an affordable Advanced Booster that meets the evolved capabilities of SLS; and enable competition by mitigating targeted Advanced Booster risks to enhance SLS affordability. Dynetics, Inc. and Aerojet Rocketdyne (AR) formed a team to offer a wide-ranging set of risk reduction activities and full-scale, system-level demonstrations that support NASA's ABEDRR goals. For NASA's SLS ABEDRR procurement, Dynetics and AR formed a team to offer a series of full-scale risk mitigation hardware demonstrations for an affordable booster approach that meets the evolved capabilities of the SLS. To establish a basis for the risk reduction activities, the Dynetics Team developed a booster design that takes advantage of the flight-proven Apollo-Saturn F-1. Using NASA's vehicle assumptions for the SLS Block 2, a two-engine, F-1-based booster design delivers 150 mT (331 klbm) payload to LEO, 20 mT (44 klbm) above NASA's requirements. This enables a low-cost, robust approach to structural design. During the ABEDRR effort, the Dynetics Team has modified proven Apollo-Saturn components and subsystems to improve affordability and reliability (e.g., reduce parts counts, touch labor, or use lower cost manufacturing processes and materials). The team has built hardware to validate production costs and completed tests to demonstrate it can meet performance requirements. State-of-the-art manufacturing and processing techniques have been applied to the heritage F-1, resulting in a low recurring cost engine while retaining the benefits of Apollo-era experience. NASA test facilities have been used to perform low-cost risk-reduction engine testing. In early 2014, NASA and the Dynetics Team agreed to move additional large liquid oxygen/kerosene engine work under Dynetics' ABEDRR contract. Also led by AR, the

  14. File list: DNS.PSC.50.AllAg.iPS_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.PSC.50.AllAg.iPS_cells hg19 DNase-seq Pluripotent stem cell iPS cells SRX040379...,SRX040378,SRX135563,SRX040376,SRX040377,SRX189427,SRX189400,SRX189399 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/DNS.PSC.50.AllAg.iPS_cells.bed ...

  15. File list: His.PSC.50.AllAg.iPS_cells [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.PSC.50.AllAg.iPS_cells mm9 Histone Pluripotent stem cell iPS cells SRX977417,SR...RX127376,SRX146530,SRX146522,SRX146547,SRX333561,SRX035985,SRX1090869 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/His.PSC.50.AllAg.iPS_cells.bed ...

  16. Density functional theory study of bulk and single-layer magnetic semiconductor CrPS4

    Science.gov (United States)

    Zhuang, Houlong L.; Zhou, Jia

    2016-11-01

    Searching for two-dimensional (2D) materials with multifunctionality is one of the main goals of current research in 2D materials. Magnetism and semiconducting are certainly two desirable functional properties for a single 2D material. In line with this goal, here we report a density functional theory (DFT) study of bulk and single-layer magnetic semiconductor CrPS4. We find that the ground-state magnetic structure of bulk CrPS4 exhibits the A-type antiferromagnetic ordering, which transforms to ferromagnetic (FM) ordering in single-layer CrPS4. The calculated formation energy and phonon spectrum confirm the stability of single-layer CrPS4. The band gaps of FM single-layer CrPS4 calculated with a hybrid density functional are within the visible-light range. We also study the effects of FM ordering on the optical absorption spectra and band alignments for water splitting, indicating that single-layer CrPS4 could be a potential photocatalyst. Our work opens up ample opportunities of energy-related applications of single-layer CrPS4.

  17. Antibody response to booster vaccination with tetanus and diphtheria in adults exposed to perfluorinated alkylates.

    Science.gov (United States)

    Kielsen, Katrine; Shamim, Zaiba; Ryder, Lars P; Nielsen, Flemming; Grandjean, Philippe; Budtz-Jørgensen, Esben; Heilmann, Carsten

    2016-01-01

    Recent studies suggest that exposure to perfluorinated alkylate substances (PFASs) may induce immunosuppression in humans and animal models. In this exploratory study, 12 healthy adult volunteers were recruited. With each subject, serum-PFAS concentrations were measured and their antibody responses prospectively followed for 30 days after a booster vaccination with diphtheria and tetanus. The results indicated that serum-PFAS concentrations were positively correlated and positively associated with age and male sex. The specific antibody concentrations in serum were increased from Day 4 to Day 10 post-booster, after which a constant concentration was reached. Serum PFAS concentrations showed significant negative associations with the rate of increase in the antibody responses. Interestingly, this effect was particularly strong for the longer-chain PFASs. All significant associations remained significant after adjustment for sex and age. Although the study involved a small number of subjects, these findings of a PFAS-associated reduction of the early humoral immune response to booster vaccination in healthy adults supported previous findings of PFAS immunosuppression in larger cohorts. Furthermore, the results suggested that cellular mechanisms right after antigen exposure should be investigated more closely to identify possible mechanisms of immunosuppression from PFAS.

  18. PS overcomes two serious magnet failures

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    Two magnets (no.'s 6 and 19)and a bus bar connection in the PS were found to be faulty during high-voltage tests at the end of the accelerator shutdown. A five-week repair schedule was quickly devised. A team of mechanics, technicians and engineers worked at full speed to replace the faulty magnets, succeeding in limiting the delay of the accelerators' spring start-up to two weeks. Pictured here are members of the PS team with the replacement no. 6 magnet. From left to right: In the back row, Frédéric Roussel (Transport DBS), Yves Bernard (Transport DBS), Luc Moreno (Cegelec), Thierry Battimanza (Transport DBS), Raymond Brown (AB/ABP), Thomas Zickler (AT/MEL); at the front, Steven Southern (AT/VAC), Thierry Gaidon (Brun & Sorensen), Philippe Vidales (Cegelec), Daniel Aubert (Cegelec), Jerome Cachet (Transport DBS), Jose Manual Gomes de Faria (AT/MEL), Eric Page (AT/VAC).

  19. Sofrimento psíquico e trabalho

    Directory of Open Access Journals (Sweden)

    Sarah Rosa Salles Vieira

    2014-03-01

    Full Text Available O presente artigo aprofunda questões clínico-téoricas relacionadas especificamente ao trabalho docente e ao sofrimento psíquico a ele relacionado a partir da observação clínica e vivência grupal nos atendimentos terapêuticos ocupacionais realizados no Hospital do Servidor Público Estadual de São Paulo "Francisco Morato de Oliveira" (HSPE-FMO. Partindo dos estudos acerca da Psicopatologia do Trabalho de Christophe Dejours, do trabalho docente e do relato de um caso clínico, caracteriza a problemática do sofrimento no trabalho, os sistemas de defesa contra este sofrimento, a ameaça à subjetividade do próprio trabalhador, as representações e conflitos vivenciados no trabalho docente, bem como a relação aditiva estabelecida como uma estratégia inconsciente de sobrevivência psíquica.

  20. Boosters and barriers for direct cardiac reprogramming.

    Science.gov (United States)

    Talkhabi, Mahmood; Zonooz, Elmira Rezaei; Baharvand, Hossein

    2017-06-01

    Heart disease is currently the most significant cause of morbidity and mortality worldwide, which accounts for approximately 33% of all deaths. Recently, a promising and alchemy-like strategy has been developed called direct cardiac reprogramming, which directly converts somatic cells such as fibroblasts to cardiac lineage cells such as cardiomyocytes (CMs), termed induced CMs or iCMs. The first in vitro cardiac reprogramming study, mediated by cardiac transcription factors (TFs)-Gata4, Tbx5 and Mef2C-, was not enough efficient to produce an adequate number of fully reprogrammed, functional iCMs. As a result, numerous combinations of cardiac TFs exist for direct cardiac reprogramming of mouse and human fibroblasts. However, the efficiency of direct cardiac reprogramming remains low. Recently, a number of cellular and molecular mechanisms have been identified to increase the efficiency of direct cardiac reprogramming and the quality of iCMs. For example, microgrooved substrate, cardiogenic growth factors [VEGF, FGF, BMP4 and Activin A], and an appropriate stoichiometry of TFs boost the direct cardiac reprogramming. On the other hand, serum, TGFβ signaling, activators of epithelial to mesenchymal transition, and some epigenetic factors (Bmi1 and Ezh2) are barriers for direct cardiac reprogramming. Manipulating these mechanisms by the application of boosters and removing barriers can increase the efficiency of direct cardiac reprogramming and possibly make iCMs reliable for cell-based therapy or other potential applications. In this review, we summarize the latest trends in cardiac TF- or miRNA-based direct cardiac reprogramming and comprehensively discuses all molecular and cellular boosters and barriers affecting direct cardiac reprogramming. Copyright © 2017 Elsevier Inc. All rights reserved.