WorldWideScience

Sample records for proximal pole nonunion

  1. Novel Treatment of a Scapholunate Ligament Injury with Proximal Pole Scaphoid Nonunion

    Science.gov (United States)

    Gaspar, Michael P.; Kane, Patrick M.; Jacoby, Sidney M.; Culp, Randall W.

    2016-01-01

    Background  Nonunion of scaphoid proximal pole fractures presents a challenging management dilemma to hand surgeons. This problem is further complicated in the uncommon concurrence of scapholunate (SL) ligament disruption. Case Description  A 39-year-old male patient presented with new-onset wrist pain following a remote history of a proximal pole scaphoid fracture sustained as a teenager, which was treated nonoperatively. Six months before presentation, the patient sustained a fall while snowboarding. The patient was found to have a chronic nonunion of his scaphoid proximal pole with an associated SL ligament disruption. As the proximal fragment was too small to be amenable to fixation, the patient was treated with an arthroscopic partial scaphoid excision and SL ligament reconstruction using a scapholunateintercarpal screw placed percutaneously. At 26 months, the patient exhibited no pain, near-normal strength, and wrist motion, and expressed a high-level of satisfaction from his surgery. Literature Review  Although cases of SL ligament disruption with concomitant proximal scaphoid fractures have been reported, to our knowledge, this is the first report of SL ligament rupture occurring in the setting of a preexisting proximal pole scaphoid nonunion. Clinical Relevance  We report the use of SL ligament reconstruction augmented with intercarpal screw fixation, and excision of the proximal pole scaphoid nonunion. This minimallyinvasive approach may be a particularly useful option in young, active patients such as our own, where a motion-sacrificing salvage procedure would be less than ideal. PMID:27616829

  2. Proximal Pole Scaphoid Nonunion Reconstruction With 1,2 Intercompartmental Supraretinacular Artery Vascularized Graft and Compression Screw Fixation.

    Science.gov (United States)

    Morris, Mark S; Zhu, Andy F; Ozer, Kagan; Lawton, Jeffrey N

    2018-02-06

    To review the incidence of union of patients with proximal pole scaphoid fracture nonunions treated using a 1,2 intercompartmental supraretinacular artery (1,2 ICSRA) vascularized graft and a small compression screw. This is a retrospective case series of 12 patients. Calculations of the size of the proximal pole fragment relative to the total scaphoid were performed using posteroanterior view scaphoid radiographs with the wrist in ulnar deviation and flat on the cassette. Analyses were repeated 3 times per subject, and the average ratio of proximal pole fragment relative to the entire scaphoid was calculated. We reviewed medical records, radiographs, and computed tomography (CT) scans of these 12 patients. The CT scans that were performed after an average of 12 weeks were ultimately used to confirm union of the scaphoid fractures. One patient was unable to have a CT so was excluded from the final calculation. All 11 (100%) scaphoid fractures that were assessed by CT were found to be healed at the 12-week assessment point. The mean proximal pole fragment size was 18% (range, 7%-27%) of the entire scaphoid. The 1,2 ICSRA vascularized graft and compression screw was an effective treatment for patients with proximal pole scaphoid fractures. Therapeutic IV. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  3. Bone graft in the treatment of nonunion of the scaphoid with necrosis of the proximal pole: a literature review.

    Science.gov (United States)

    Severo, Antônio Lourenço; Lemos, Marcelo Barreto; Lech, Osvandré Luiz Canfield; Barreto Filho, Danilo; Strack, Daniel Paulo; Candido, Larissa Knapp

    2017-01-01

    Scaphoid fractures are the most common fractures of the carpal bones, corresponding to 60%. Of these, 10% progress to nonunion; moreover, 3% can present necrosis of the proximal pole. There are various methods of treatment using vascularized and non-vascularized bone grafts. To evaluate and compare the rate of scaphoid consolidation with necrosis of the proximal pole using different surgical techniques. The authors conducted a review of the literature using the following databases: PubMed and BIREME/LILACS, where 13 case series were selected (ten with use of vascularized bone grafts and three of non-vascularized bone grafts), according to inclusion and exclusion criteria. In most cases VBGs were used, especially those based on the 1,2 intercompartmental supraretinacular artery, due to greater reproducibility in performing the surgical technique.

  4. A Scapholunate Ligament-Sparing Technique Utilizing the Medial Femoral Condyle Corticocancellous Free Flap to Reconstruct Scaphoid Nonunions With Proximal Pole Avascular Necrosis.

    Science.gov (United States)

    Kazmers, Nikolas H; Thibaudeau, Stephanie; Levin, L Scott

    2016-09-01

    This article demonstrates a technique for the treatment of scaphoid fracture waist and proximal pole nonunions with avascular necrosis using a free vascularized medial femoral condyle flap. We present our surgical technique and representative case examples in which the scapholunate ligament, a key structure required to preserve carpal kinematics, is spared. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  5. Avascular necrosis (AVN) of the proximal fragment in scaphoid nonunion: Is intravenous contrast agent necessary in MRI?

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, R., E-mail: schmitt.radiologie@herzchirurgie.de [Department of Diagnostic and Interventional Radiology, Cardiovascular Center, Bad Neustadt an der Saale (Germany); Christopoulos, G.; Wagner, M. [Department of Diagnostic and Interventional Radiology, Cardiovascular Center, Bad Neustadt an der Saale (Germany); Krimmer, H. [Department of Hand Surgery, Cardiovascular Center, Bad Neustadt an der Saale (Germany); Fodor, S. [Department of Diagnostic and Interventional Radiology, Cardiovascular Center, Bad Neustadt an der Saale (Germany); Schoonhoven, J. van; Prommersberger, K.J. [Department of Hand Surgery, Cardiovascular Center, Bad Neustadt an der Saale (Germany)

    2011-02-15

    Purpose: The purpose of this prospective study is to assess the diagnostic value of intravenously applied contrast agent for diagnosing osteonecrosis of the proximal fragment in scaphoid nonunion, and to compare the imaging results with intraoperative findings. Materials and methods: In 88 patients (7 women, 81 men) suffering from symptomatic scaphoid nonunion, preoperative MRI was performed (coronal PD-w FSE fs, sagittal-oblique T1-w SE nonenhanced and T1-w SE fs contrast-enhanced, sagittal T2*-w GRE). MRI interpretation was based on the intensity of contrast enhancement: 0 = none, 1 = focal, 2 = diffuse. Intraoperatively, the osseous viability was scored by means of bleeding points on the osteotomy site of the proximal scaphoid fragment: 0 = absent, 1 = moderate, 2 = good. Results: Intraoperatively, 17 necrotic, 29 compromised, and 42 normal proximal fragments were found. In nonenhanced MRI, bone viability was judged necrotic in 1 patient, compromised in 20 patients, and unaffected in 67 patients. Contrast-enhanced MRI revealed 14 necrotic, 21 compromised, and 53 normal proximal fragments. Judging surgical findings as the standard of reference, statistical analysis for nonenhanced MRI was: sensitivity 6.3%, specificity 100%, positive PV 100%, negative PV 82.6%, and accuracy 82.9%; statistics for contrast-enhanced MRI was: sensitivity 76.5%, specificity 98.6%, positive PV 92.9%, negative PV 94.6%, and accuracy 94.3%. Sensitivity for detecting avascular proximal fragments was significantly better (p < 0.001) in contrast-enhanced MRI in comparison to nonenhanced MRI. Conclusion: Viability of the proximal fragment in scaphoid nonunion can be significantly better assessed with the use of contrast-enhanced MRI as compared to nonenhanced MRI. Bone marrow edema is an inferior indicator of osteonecrosis. Application of intravenous gadolinium is recommended for imaging scaphoid nonunion.

  6. Avascular necrosis (AVN) of the proximal fragment in scaphoid nonunion: Is intravenous contrast agent necessary in MRI?

    International Nuclear Information System (INIS)

    Schmitt, R.; Christopoulos, G.; Wagner, M.; Krimmer, H.; Fodor, S.; Schoonhoven, J. van; Prommersberger, K.J.

    2011-01-01

    Purpose: The purpose of this prospective study is to assess the diagnostic value of intravenously applied contrast agent for diagnosing osteonecrosis of the proximal fragment in scaphoid nonunion, and to compare the imaging results with intraoperative findings. Materials and methods: In 88 patients (7 women, 81 men) suffering from symptomatic scaphoid nonunion, preoperative MRI was performed (coronal PD-w FSE fs, sagittal-oblique T1-w SE nonenhanced and T1-w SE fs contrast-enhanced, sagittal T2*-w GRE). MRI interpretation was based on the intensity of contrast enhancement: 0 = none, 1 = focal, 2 = diffuse. Intraoperatively, the osseous viability was scored by means of bleeding points on the osteotomy site of the proximal scaphoid fragment: 0 = absent, 1 = moderate, 2 = good. Results: Intraoperatively, 17 necrotic, 29 compromised, and 42 normal proximal fragments were found. In nonenhanced MRI, bone viability was judged necrotic in 1 patient, compromised in 20 patients, and unaffected in 67 patients. Contrast-enhanced MRI revealed 14 necrotic, 21 compromised, and 53 normal proximal fragments. Judging surgical findings as the standard of reference, statistical analysis for nonenhanced MRI was: sensitivity 6.3%, specificity 100%, positive PV 100%, negative PV 82.6%, and accuracy 82.9%; statistics for contrast-enhanced MRI was: sensitivity 76.5%, specificity 98.6%, positive PV 92.9%, negative PV 94.6%, and accuracy 94.3%. Sensitivity for detecting avascular proximal fragments was significantly better (p < 0.001) in contrast-enhanced MRI in comparison to nonenhanced MRI. Conclusion: Viability of the proximal fragment in scaphoid nonunion can be significantly better assessed with the use of contrast-enhanced MRI as compared to nonenhanced MRI. Bone marrow edema is an inferior indicator of osteonecrosis. Application of intravenous gadolinium is recommended for imaging scaphoid nonunion.

  7. Avascular necrosis (AVN) of the proximal fragment in scaphoid nonunion: is intravenous contrast agent necessary in MRI?

    Science.gov (United States)

    Schmitt, R; Christopoulos, G; Wagner, M; Krimmer, H; Fodor, S; van Schoonhoven, J; Prommersberger, K J

    2011-02-01

    The purpose of this prospective study is to assess the diagnostic value of intravenously applied contrast agent for diagnosing osteonecrosis of the proximal fragment in scaphoid nonunion, and to compare the imaging results with intraoperative findings. In 88 patients (7 women, 81 men) suffering from symptomatic scaphoid nonunion, preoperative MRI was performed (coronal PD-w FSE fs, sagittal-oblique T1-w SE nonenhanced and T1-w SE fs contrast-enhanced, sagittal T2*-w GRE). MRI interpretation was based on the intensity of contrast enhancement: 0 = none, 1 = focal, 2 = diffuse. Intraoperatively, the osseous viability was scored by means of bleeding points on the osteotomy site of the proximal scaphoid fragment: 0=absent, 1 = moderate, 2 = good. Intraoperatively, 17 necrotic, 29 compromised, and 42 normal proximal fragments were found. In nonenhanced MRI, bone viability was judged necrotic in 1 patient, compromised in 20 patients, and unaffected in 67 patients. Contrast-enhanced MRI revealed 14 necrotic, 21 compromised, and 53 normal proximal fragments. Judging surgical findings as the standard of reference, statistical analysis for nonenhanced MRI was: sensitivity 6.3%, specificity 100%, positive PV 100%, negative PV 82.6%, and accuracy 82.9%; statistics for contrast-enhanced MRI was: sensitivity 76.5%, specificity 98.6%, positive PV 92.9%, negative PV 94.6%, and accuracy 94.3%. Sensitivity for detecting avascular proximal fragments was significantly better (p<0.001) in contrast-enhanced MRI in comparison to nonenhanced MRI. Viability of the proximal fragment in scaphoid nonunion can be significantly better assessed with the use of contrast-enhanced MRI as compared to nonenhanced MRI. Bone marrow edema is an inferior indicator of osteonecrosis. Application of intravenous gadolinium is recommended for imaging scaphoid nonunion. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  8. Is dynamic contrast-enhanced MRI useful for assessing proximal fragment vascularity in scaphoid fracture delayed and non-union?

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Alex W.H.; Griffith, James F.; Li, Alvin [The Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Prince of Wales Hospital, Hong Kong, SAR (China); Taljanovic, Mihra S. [The University of Arizona Health Network, Department of Medical Imaging, 1501 N. Campbell Ave., P.O. Box 245067, Tucson, AZ (United States); Tse, W.L.; Ho, P.C. [The Chinese University of Hong Kong, Department of Orthopedics and Traumatology, Prince of Wales Hospital, Hong Kong (China)

    2013-07-15

    To assess dynamic contrast-enhanced magnetic resonance imaging (DCE MRI) as a measure of vascularity in scaphoid delayed-union or non-union. Thirty-five patients (34 male, one female; mean age, 27.4 {+-} 9.4 years; range, 16-51 years) with scaphoid delayed-union and non-union who underwent DCE MRI of the scaphoid between September 2002 and October 2012 were retrospectively reviewed. Proximal fragment vascularity was classified as good, fair, or poor on unenhanced MRI, contrast-enhanced MRI, and DCE MRI. For DCE MRI, enhancement slope, E{sub slope} comparison of proximal and distal fragments was used to classify the proximal fragment as good, fair, or poor vascularity. Proximal fragment vascularity was similarly graded at surgery in all patients. Paired t test and McNemar test were used for data comparison. Kappa value was used to assess level of agreement between MRI findings and surgical findings. Twenty-five (71 %) of 35 patients had good vascularity, four (11 %) had fair vascularity, and six (17 %) had poor vascularity of the proximal scaphoid fragment at surgery. DCE MRI parameters had the highest correlation with surgical findings (kappa = 0.57). Proximal scaphoid fragments with surgical poor vascularity had a significantly lower E{sub max} and E{sub slope} than those with good vascularity (p = 0.0043 and 0.027). The sensitivity, specificity, positive and negative predictive value and accuracy of DCE MRI in predicting impaired vascularity was 67, 86, 67, 86, and 80 %, respectively, which was better than that seen with unenhanced and post-contrast MRI. Flattened time intensity curves in both proximal and distal fragments were a feature of protracted non-union with a mean time interval of 101.6 {+-} 95.5 months between injury and MRI. DCE MRI has a higher diagnostic accuracy than either non-enhanced MRI or contrast enhanced MRI for assessing proximal fragment vascularity in scaphoid delayed-union and non-union. For proper interpretation of contrast

  9. Surgical Management of Proximal Interphalangeal Joint Repetitive Stress Epiphyseal Fracture Nonunion in Elite Sport Climbers.

    Science.gov (United States)

    El-Sheikh, Yasser; Lutter, Chris; Schoeffl, Isabelle; Schoeffl, Volker; Flohe, Sascha

    2017-11-14

    Repetitive stress fracture of the middle phalanx epiphysis is an injury specific to elite adolescent sport climbers. As sport climbing becomes increasingly popular in younger age groups, an increased number of these injuries have been reported in recent years. To date, treatment of these fractures has been nonsurgical, with strict rest and physiotherapy prescribed until fracture union. However, when these patients present in a delayed fashion with an established nonunion, nonsurgical treatment may fail, leading to disabling chronic pain and/or digital deformity in some cases. In this article, we present 2 cases of surgical treatment for finger middle phalanx repetitive stress epiphyseal fracture nonunion, using a percutaneous spot drilling epiphysiodesis technique. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  10. Accuracy of enhanced and unenhanced MRI in diagnosing scaphoid proximal pole avascular necrosis and predicting surgical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Fox, M.G. [University of Virginia, Department of Radiology and Medical Imaging, Charlottesville, VA (United States); Wang, D.T. [University of Virginia, Department of Radiology and Medical Imaging, Charlottesville, VA (United States); Medical College of Wisconsin, Milwaukee, WI (United States); Chhabra, A.B. [University of Virginia Health System, Department of Orthopedics, Charlottesville, VA (United States)

    2015-11-15

    Determine the sensitivity, specificity and accuracy of unenhanced and enhanced MRI in diagnosing scaphoid proximal pole (PP) avascular necrosis (AVN) and correlate whether MRI can help guide the selection of a vascularized or nonvascularized bone graft. The study was approved by the IRB. Two MSK radiologists independently performed a retrospective review of unenhanced and enhanced MRIs from 18 patients (16 males, 2 females; median age, 17.5 years) with scaphoid nonunions and surgery performed within 65 days of the MRI. AVN was diagnosed on the unenhanced MRI when a diffusely decreased T1-W signal was present in the PP and on the enhanced MRI when PP enhancement was less than distal pole enhancement. Surgical absence of PP bleeding was diagnostic of PP AVN. Postoperative osseous union (OU) was assessed with computed tomography and/or radiographs. Sensitivity, specificity and accuracy for PP AVN were 71, 82 and 78 % for unenhanced and 43, 82 and 67 % for enhanced MRI. Patients with PP AVN on unenhanced MRI had 86 % (6/7) OU; 100 % (5/5) OU with vascularized bone grafts and 50 % (1/2) OU with nonvascularized grafts. Patients with PP AVN on enhanced MRI had 80 % (4/5) OU; 100 % (3/3) OU with vascularized bone grafts and 50 % (1/2) OU with nonvascularized grafts. Patients with viable PP on unenhanced and enhanced MRI had 91 % (10/11) and 92 % (12/13) OU, respectively, all but one with nonvascularized graft. When PP AVN is evident on MRI, OU is best achieved with vascularized grafts. If PP AVN is absent, OU is successful with nonvascularized grafts. (orig.)

  11. Accuracy of enhanced and unenhanced MRI in diagnosing scaphoid proximal pole avascular necrosis and predicting surgical outcome

    International Nuclear Information System (INIS)

    Fox, M.G.; Wang, D.T.; Chhabra, A.B.

    2015-01-01

    Determine the sensitivity, specificity and accuracy of unenhanced and enhanced MRI in diagnosing scaphoid proximal pole (PP) avascular necrosis (AVN) and correlate whether MRI can help guide the selection of a vascularized or nonvascularized bone graft. The study was approved by the IRB. Two MSK radiologists independently performed a retrospective review of unenhanced and enhanced MRIs from 18 patients (16 males, 2 females; median age, 17.5 years) with scaphoid nonunions and surgery performed within 65 days of the MRI. AVN was diagnosed on the unenhanced MRI when a diffusely decreased T1-W signal was present in the PP and on the enhanced MRI when PP enhancement was less than distal pole enhancement. Surgical absence of PP bleeding was diagnostic of PP AVN. Postoperative osseous union (OU) was assessed with computed tomography and/or radiographs. Sensitivity, specificity and accuracy for PP AVN were 71, 82 and 78 % for unenhanced and 43, 82 and 67 % for enhanced MRI. Patients with PP AVN on unenhanced MRI had 86 % (6/7) OU; 100 % (5/5) OU with vascularized bone grafts and 50 % (1/2) OU with nonvascularized grafts. Patients with PP AVN on enhanced MRI had 80 % (4/5) OU; 100 % (3/3) OU with vascularized bone grafts and 50 % (1/2) OU with nonvascularized grafts. Patients with viable PP on unenhanced and enhanced MRI had 91 % (10/11) and 92 % (12/13) OU, respectively, all but one with nonvascularized graft. When PP AVN is evident on MRI, OU is best achieved with vascularized grafts. If PP AVN is absent, OU is successful with nonvascularized grafts. (orig.)

  12. Accuracy of enhanced and unenhanced MRI in diagnosing scaphoid proximal pole avascular necrosis and predicting surgical outcome.

    Science.gov (United States)

    Fox, M G; Wang, D T; Chhabra, A B

    2015-11-01

    Determine the sensitivity, specificity and accuracy of unenhanced and enhanced MRI in diagnosing scaphoid proximal pole (PP) avascular necrosis (AVN) and correlate whether MRI can help guide the selection of a vascularized or nonvascularized bone graft. The study was approved by the IRB. Two MSK radiologists independently performed a retrospective review of unenhanced and enhanced MRIs from 18 patients (16 males, 2 females; median age, 17.5 years) with scaphoid nonunions and surgery performed within 65 days of the MRI. AVN was diagnosed on the unenhanced MRI when a diffusely decreased T1-W signal was present in the PP and on the enhanced MRI when PP enhancement was less than distal pole enhancement. Surgical absence of PP bleeding was diagnostic of PP AVN. Postoperative osseous union (OU) was assessed with computed tomography and/or radiographs. Sensitivity, specificity and accuracy for PP AVN were 71, 82 and 78% for unenhanced and 43, 82 and 67% for enhanced MRI. Patients with PP AVN on unenhanced MRI had 86% (6/7) OU; 100% (5/5) OU with vascularized bone grafts and 50% (1/2) OU with nonvascularized grafts. Patients with PP AVN on enhanced MRI had 80% (4/5) OU; 100% (3/3) OU with vascularized bone grafts and 50% (1/2) OU with nonvascularized grafts. Patients with viable PP on unenhanced and enhanced MRI had 91% (10/11) and 92% (12/13) OU, respectively, all but one with nonvascularized graft. When PP AVN is evident on MRI, OU is best achieved with vascularized grafts. If PP AVN is absent, OU is successful with nonvascularized grafts.

  13. Using computed tomography to assist with diagnosis of avascular necrosis complicating chronic scaphoid nonunion.

    Science.gov (United States)

    Smith, Michael L; Bain, Gregory I; Chabrel, Nick; Turner, Perry; Carter, Chris; Field, John

    2009-01-01

    The primary aim of our study was to investigate use of long axis computed tomography (CT) in predicting avascular necrosis of the proximal pole of the scaphoid and subsequent fracture nonunion after internal fixation. In addition, we describe a new technique of measuring the position of a scaphoid fracture and provide data on its reproducibility. Thirty-one patients operated on by the senior author for delayed union or nonunion of scaphoid fracture were included. Preoperative CT scans were independently assessed for increased radiodensity of the proximal pole, converging trabeculae, degree of deformity, comminution, and fracture position. Intraoperative biopsies of the proximal pole were obtained and histologically assessed for evidence of avascular necrosis. The radiologic variables were statistically compared with the histologic findings. The presence of avascular necrosis was also compared with postoperative union status, identified on longitudinal CT scans. Preoperative CT features that statistically correlated with histologic evidence of avascular necrosis were increased radiodensity of the proximal pole and the absence of any converging trabeculae between the fracture fragments. The radiologic changes of avascular necrosis and the histologic confirmation of avascular necrosis were associated with persistent nonunion. Preoperative longitudinal CT of scaphoid nonunion is of great value in identifying avascular necrosis and predicting subsequent fracture union. If avascular necrosis is suspected based on preoperative CT, management options include vascularized bone grafts and bone morphogenic protein for younger patients and limited wrist arthrodesis for older patients. Diagnostic II.

  14. MR imaging of avascular scaphoid nonunion before and after vascularized bone grafting

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Suzanne E.; Tschering-Vogel, Dechen; Martin, Matthias [University Hospital of Bern, Inselspital, Department of Radiology, Bern (Switzerland); Steinbach, Lynne S. [University of California San Francisco, Department of Radiology, San Francisco, California (United States); Nagy, Ladislav [University Hospital of Bern, Inselspital, Department of Orthopedic Surgery, Bern (Switzerland)

    2005-06-01

    To investigate the magnetic resonance (MR) imaging appearances of chronic nonunion of the scaphoid with proximal pole avascular necrosis before and after insertion of a vascularized bone graft, using computed tomography (CT) as the imaging gold standard. A retrospective study was performed involving MR imaging (n=26), CT scans (n=37) and radiographs (n=52) of 13 men (mean age 29 years, age range 20-38 years) with avascular scaphoid nonunion. Avascular necrosis of the scaphoid proximal pole was confirmed intraoperatively (n=13). MR images were acquired preoperatively and following placement of a vascularized bone graft. Scaphoid MR signal characteristics were assessed for evidence of vascular bone graft incorporation and revascularization of the bone marrow of the proximal pole of the scaphoid and compared with the gold standard of CT. Surgical and clinical notes were reviewed with a minimum 3 year imaging and clinical follow-up in all patients. Graft incorporation with revascularization of the proximal pole of the scaphoid was documented in 9 patients (69%). Graft failure with persistent pseudoarthrosis and avascular necrosis of the scaphoid was seen in 4 patients (31%). MR imaging is useful to determine whether vascularized bone graft incorporation and revascularization of the proximal pole of the scaphoid has occurred in the setting of avascular scaphoid nonunion. (orig.)

  15. MR imaging of avascular scaphoid nonunion before and after vascularized bone grafting

    International Nuclear Information System (INIS)

    Anderson, Suzanne E.; Tschering-Vogel, Dechen; Martin, Matthias; Steinbach, Lynne S.; Nagy, Ladislav

    2005-01-01

    To investigate the magnetic resonance (MR) imaging appearances of chronic nonunion of the scaphoid with proximal pole avascular necrosis before and after insertion of a vascularized bone graft, using computed tomography (CT) as the imaging gold standard. A retrospective study was performed involving MR imaging (n=26), CT scans (n=37) and radiographs (n=52) of 13 men (mean age 29 years, age range 20-38 years) with avascular scaphoid nonunion. Avascular necrosis of the scaphoid proximal pole was confirmed intraoperatively (n=13). MR images were acquired preoperatively and following placement of a vascularized bone graft. Scaphoid MR signal characteristics were assessed for evidence of vascular bone graft incorporation and revascularization of the bone marrow of the proximal pole of the scaphoid and compared with the gold standard of CT. Surgical and clinical notes were reviewed with a minimum 3 year imaging and clinical follow-up in all patients. Graft incorporation with revascularization of the proximal pole of the scaphoid was documented in 9 patients (69%). Graft failure with persistent pseudoarthrosis and avascular necrosis of the scaphoid was seen in 4 patients (31%). MR imaging is useful to determine whether vascularized bone graft incorporation and revascularization of the proximal pole of the scaphoid has occurred in the setting of avascular scaphoid nonunion. (orig.)

  16. An alternative graft fixation technique for scaphoid nonunions treated with vascular bone grafting.

    Science.gov (United States)

    Korompilias, Anastasios V; Lykissas, Marios G; Kostas-Agnantis, Ioannis P; Gkiatas, Ioannis; Beris, Alexandros E

    2014-07-01

    To present our experience with vascularized bone grafting based on the 1,2-intercompartmental supraretinacular artery for the management of established scaphoid nonunion and to investigate the efficacy of graft immobilization with a combination of Kirschner wires and transarticular external fixation. A retrospective chart and radiographic review was conducted for patients with the diagnosis of scaphoid nonunion of the proximal pole or the waist treated with the 1,2-intercompartmental supraretinacular artery-based vascularized graft and fixed with a combination of Kirschner wires and transarticular external fixation between 2007 and 2011. We observed 23 consecutive patients for a mean of 34 ± 4 months. All patients were males with mean age of 25 ± 5 years. All patients had scaphoid nonunion and associated humpback deformity. The mean duration of nonunion was 7 ± 1 months. All scaphoid nonunions united after the index procedure at a mean of 10 ± 1 weeks. Two patients had avascular necrosis of the proximal pole based on the preoperative magnetic resonance imaging findings. After surgery, deformity correction was achieved in all patients, as recorded by the decrease in the lateral intrascaphoid angle and the increase in the dorsal scaphoid angle. At the last follow-up, no patients reported wrist pain. The mean Disabilities of the Arm, Shoulder, and Hand score improved significantly from 32 ± 12 before the operation to 5 ± 3 at the last postoperative visit. All patients showed statistically significant improvement in the range of motion and the grip strength of the involved wrist. The results of this study support the combined use of Kirschner wires and transarticular external fixation for fixation of a 1,2-intercompartmental supraretinacular artery-based vascular bone graft in the treatment of scaphoid nonunions. Therapeutic IV. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  17. Infected nonunion of tibia

    Directory of Open Access Journals (Sweden)

    Milind Madhav Chaudhary

    2017-01-01

    Full Text Available Infected nonunions of tibia pose many challenges to the treating surgeon and the patient. Challenges include recalcitrant infection, complex deformities, sclerotic bone ends, large bone gaps, shortening, and joint stiffness. They are easy to diagnose and difficult to treat. The ASAMI classification helps decide treatment. The nonunion severity score proposed by Calori measures many parameters to give a prognosis. The infection severity score uses simple clinical signs to grade severity of infection. This determines number of surgeries and allows choice of hardware, either external or internal for definitive treatment. Co-morbid factors such as smoking, diabetes, nonsteroidal anti-inflammatory drug use, and hypovitaminosis D influence the choice and duration of treatment. Thorough debridement is the mainstay of treatment. Removal of all necrotic bone and soft tissue is needed. Care is exercised in shaping bone ends. Internal fixation can help achieve union if infection was mild. Severe infections need external fixation use in a second stage. Compression at nonunion site achieves union. It can be combined with a corticotomy lengthening at a distant site for equalization. Soft tissue deficit has to be covered by flaps, either local or microvascular. Bone gaps are best filled with the reliable technique of bone transport. Regenerate bone may be formed proximally, distally, or at both sites. Acute compression can fill bone gaps and may need a fibular resection. Gradual reduction of bone gap happens with bone transport, without need for fibulectomy. When bone ends dock, union may be achieved by vertical or horizontal compression. Biological stimulus from iliac crest bone grafts, bone marrow aspirate injections, and platelet concentrates hasten union. Bone graft substitutes add volume to graft and help fill defects. Addition of rh-BMP-7 may help in healing albeit at a much higher cost. Regeneration may need stimulation and augmentation. Induced

  18. Nonunions of the distal tibia treated by reamed intramedullary nailing

    NARCIS (Netherlands)

    Richmond, Jeffrey; Colleran, Kevin; Borens, Olivier; Kloen, Peter; Helfet, David L.

    2004-01-01

    The purpose of this study is to determine the efficacy of reamed intramedullary nailing in the treatment of nonunions of the distal one-fourth of the tibia. Nonunions of the distal tibia are particularly difficult to treat given the short distal segment, the proximity to the ankle joint, and the

  19. Management of scaphoid nonunion with avascular necrosis using 1,2 intercompartmental supraretinacular arterial bone graft

    Directory of Open Access Journals (Sweden)

    Mohamad Dehghani

    2014-01-01

    Full Text Available Background: 1,2 ICSRA, introduced by Aidembery et al., is a well-established technique, with up to 100% union rate among different studies . The purpose of our study was to evaluate the outcome of scaphoid nonunion undergoing 1,2 ICSRA bone graft in Iran. Materials and Methods: All participants who presented sequentially over a period of 24 months between 2010 and 2013 with nonunion scaphoid fracture with AVN in proximal pole were included in the study. Anteroposterior and lateral view plain radiographs of carpal bones were obtained for diagnosis of nonunion, and a diagnosis of avascular necrosis was made by MRI of the scaphoid. Subjects underwent 1,2 ICSRA bone graft surgery. Patients were assessed based on radiographs and the Mayo Wrist Score (MWS questionnaire on before and after surgery. Data were analyzed using SPSS ver. 18 by paired t test. Results: Overall, 16 patients (100% male were included in the study. Mean age of subjects was 27.50 ± 5.86 (18 to 38. Mean Mayo score was 36.63 ± 8.92 and 83.75 ± 9.22 before and 6 month after surgery, respectively, and the difference was statistically significant (P < 0.001. after 8 weeks, 10 (62.5% had union, and after 12 weeks, all subjects had union. Nine (56.25% of our patients had excellent functional outcome, 5 (31.25% had good and 2 (12.5% had satisfactory functional outcome. Conclusion: 1,2 ICSRA is a proper pedicle of vascularized bone graft due to the ease of visibility and dissection. The functional results and union rates were satisfactory in our study.

  20. Automated Mounting of Pole-Shoe Wedges in Linear Wave Power Generators—Using Industrial Robotics and Proximity Sensors

    Directory of Open Access Journals (Sweden)

    Tobias Kamf

    2017-03-01

    Full Text Available A system for automatic mounting of high tolerance wedges inside a wave power linear generator is proposed. As for any renewable energy concept utilising numerous smaller generation units, minimising the production cost per unit is vital for commercialization. The linear generator in question uses self-locking wedges, which are challenging to mount using industrial robots due to the high tolerances used, and because of the fact that any angular error remaining after calibration risks damaging the equipment. Using two types of probes, mechanical touch probes and inductive proximity sensors, combined with a flexible robot tool and iterative calibration routines, an automatic mounting system that overcomes the challenges of high tolerance wedge mounting is presented. The system is experimentally verified to work at mounting speeds of up to 50mm/s, and calibration accuracies of 0.25mmand 0.1 ∘ are achieved. The use of a flexible robot tool, able to move freely in one Cartesian plane, was found to be essential for making the system work.

  1. [New research progress on atrophic nonunion].

    Science.gov (United States)

    Wei, Jun-Qiang; Zhang, Bo-Xun; Chen, Hua; Tang, Pei-Fu; Wang, Yan

    2012-12-01

    Occurance of atrophic nonunion is a complex process. Previous studies suggested that atrophic nonunion was mainly due to lack of blood supply of fracture fragments, but recent studies found that blood supply was not deficiency in middle and late stages, indicating that decreased osteogenic factors and blood supply in early stages might play an important role in morbidity. Current effective treatment measures for atrophic nonunion mainly include bone graft and fixation,physical therapy, local injection therapy. All-round preventive could reduce incidence of atrophic nonunion. Atrophic nonunion is still a troublesome complication of fractures in orthopaedics, and more attention should be paid for its effective prevention and treatment. The paper summarized recent original articles about atrophic nonunion and reviewed the occurrence mechanisms, diagnosis, prevention and treatment measures of this disease.

  2. Hypertrophic Nonunion Humerus Mimicking an Enchondroma

    Directory of Open Access Journals (Sweden)

    N. K. Magu

    2014-01-01

    Full Text Available Introduction. Although fractures of humeral shaft show excellent results with conservative management, nonunion does occur. Case Report. We bring forth the case of a young male with a 1.5-year-old hypertrophic nonunion of the humerus mimicking an enchondroma. The initial X-ray images of the patient appeared to be an enchondroma, which only on further evaluation and histopathological analysis was diagnosed conclusively to be a hypertrophic nonunion. Discussion. Enchondromas are often incidentally diagnosed benign tumours. It is however not common to misdiagnose a hypertrophic nonunion to be an enchondroma. We present this case to highlight the unique diagnostic dilemma the treating team had to face.

  3. Tibia shaft fractures: costly burden of nonunions

    Directory of Open Access Journals (Sweden)

    Antonova Evgeniya

    2013-01-01

    Full Text Available Abstract Background Tibia shaft fractures (TSF are common for men and women and cause substantial morbidity, healthcare use, and costs. The impact of nonunions on healthcare use and costs is poorly described. Our goal was to investigate patient characteristics and healthcare use and costs associated with TSF in patients with and without nonunion. Methods We retrospectively analyzed medical claims in large U.S. managed care claims databases (Thomson Reuters MarketScan®, 16 million lives. We studied patients ≥ 18 years old with a TSF diagnosis (ICD-9 codes: 823.20, 823.22, 823.30, 823.32 in 2006 with continuous pharmaceutical and medical benefit enrollment 1 year prior and 2 years post-fracture. Nonunion was defined by ICD-9 code 733.82 (after the TSF date. Results Among the 853 patients with TSF, 99 (12% had nonunion. Patients with nonunion had more comorbidities (30 vs. 21, pre-fracture and were more likely to have their TSF open (87% vs. 70% than those without nonunion. Patients with nonunion were more likely to have additional fractures during the 2-year follow-up (of lower limb [88.9% vs. 69.5%, P  Conclusions Nonunions in TSF’s are associated with substantial healthcare resource use, common use of strong opioids, and high per-patient costs. Open fractures are associated with higher likelihood of nonunion than closed ones. Effective screening of nonunion risk may decrease this morbidity and subsequent healthcare resource use and costs.

  4. Non-vascularized iliac bone grafting for scaphoid nonunion with avascular necrosis.

    Science.gov (United States)

    Kim, Jihyeung; Park, Jin Woo; Chung, Jeehyeok; Jeong Bae, Kee; Gong, Hyun Sik; Baek, Goo Hyun

    2018-01-01

    We present the surgical outcomes of non-vascularized bone grafting taken from the iliac crest in 24 patients with scaphoid nonunion and avascular necrosis. The Fisk-Fernandez technique was used in 11 patients, and cancellous bone grafting was used in 13 patients. Bony union was achieved in 22 of the 24 patients. Non-vascularized iliac bone grafting can be used for the surgical management of scaphoid nonunion with avascular necrosis. Although revascularization of the proximal fragment after surgery was not evaluated, bony union was confirmed in nearly all patients. IV.

  5. Low-intensity pulsed ultrasound: Nonunions

    Directory of Open Access Journals (Sweden)

    Dijkman Bernadette

    2009-01-01

    Full Text Available Nonunions occur in 5-10% of fractures and are characterized by the failure to heal without further intervention. Low intensity pulsed ultrasound therapy has been developed as an alternative to surgery in the treatment of nonunions. We describe a systematic review on trials of low-intensity pulsed ultrasound therapy for healing of nonunions. We searched the electronic databases Medline and the Cochrane library for articles on ultrasound and healing of nonunions published up to 2008. Trials selected for the review met the following criteria: treatment of at least one intervention group with low intensity pulsed ultrasound; inclusion of patients (humans with one or more nonunions (defined as "established" or as a failure to heal for a minimum of eight months after initial injury; and assessment of healing and time to healing, as determined radiographically. The following data were abstracted from the included studies: sample size, ultrasound treatment characteristics, nonunion location, healing rate, time to fracture healing, fracture age, and demographic information. We found 79 potentially eligible publications, of which 14 met our inclusion criteria. Of these, eight studies were used for data abstraction. Healing rates averaged 87%, (range 65.6%-100% among eight trials. Mean time to healing was 146.5 days, (range 56-219 days. There is evidence from trials that low-intensity pulsed ultrasound may be an effective treatment for healing of nonunions. More homogeneous and larger controlled series are needed to further investigate its efficacy.

  6. Gap nonunion of tibia treated by Huntington′s procedure

    Directory of Open Access Journals (Sweden)

    Zile S Kundu

    2012-01-01

    Full Text Available Background: Gap nonunion that may occur following trauma or infection is a challenging problem to treat. The patients with intact or united fibula, preserved sensation in the sole, and adequate vascularity, were managed by tibialization (medialization of the fibula (Huntington′s procedure, to restore continuity of the tibia. The goal of this retrospective analysis study is to report the mid-term results following the Huntington′s procedure. Materials and Methods: 22 patients (20 males and two females age 16-34 years with segmental tibial loss more than 6 cm were operated for tibialization of fibula. The procedure was two-staged in seven and single-staged in the rest 15 patients, where the lateral aspect of the leg was relatively supple. In the two-staged procedure, the distal tibiofibular synostosis was performed six-to-eight weeks after the proximal procedure. Weightbearing (protected was started in a long leg cast after six-to-eight weeks of the second stage and continued for six-to-eight months, followed by the use of a brace. Results: The fibula started showing signs of hypertrophy within the first year after the procedure and it was more than double in breath after the four-year period. Full and unprotected weightbearing on the operated leg was achieved at an average time of 16 months. At the final followup, ten patients were very satisfied, seven satisfied, and five fairly satisfied. One patient had persistent nonunion at the proximal synostotic site even after bone grafting and secondary fixation. Conclusion: Huntington′s procedure is a safe and simple salvage procedure and remains an excellent option for treating difficult infected nonunion of the tibia in the selected indications.

  7. Application of monorail fixator for femoral gap nonunion.

    Science.gov (United States)

    Agrawal, Hemendra-Kumar; Jaiman, Ashish; Khatkar, Vipin; Sharma, Vinod-Kumar

    2014-01-01

    Difficult femoral nonunion takes account of infective nonunion and aseptic gap nonunion. Limb length discrepancy and nonunion need to be tackled simultaneously. Conventionally Ilizarov ring fixator is in vogue but it has some limitations. To overcome these, monorail fixator is an effective alternative. Persistent good results can be obtained if we can get a perfect anatomical alignment and good regeneration.

  8. Osteosynthesis for symptomatic ulnar styloid nonunion

    International Nuclear Information System (INIS)

    Kajiwara, Ryoji; Kimori, Kenji; Kawagoe, Hiroyuki; Tsuge, Kenya; Ikuta, Yosikazu

    2008-01-01

    We reviewed cases of osteosynthesis for symptomatic ulnar styloid nonunion. Since 1998, 13 cases of ulnar styloid nonunion have been treated by osteosynthesis. The patients were 10 men and 3 women, with a mean age of 27 years (range 11-65). The nonunion site was located in the middle in one case, in the base in 8 cases, and in the epiphyseal region in 4 cases. Osteosynthesis was performed with tension band wiring in all cases, and cancellous bone graft was performed in 12 of 13 cases. Distal radioulnar joint (DRUJ) instability was found by radiograph or CT in four cases; in two of these, osteosynthesis alone did not improve DRUJ instability and additional DRUJ stabilization was performed. One patient whose treatment failed to correct nonunion did not seek further treatment. In another case, an additional surgery was performed 1 week after the initial surgery to correct displacement of the fragment. The mean follow-up period was 15 months (range 8-45 months). According to Hauck's criteria, final pain was evaluated as excellent in nine cases, good in three cases, including the case resulting in nonunion, and fair in one case. (author)

  9. Nonunion of an isolated cuboid fracture: a case report.

    Science.gov (United States)

    Britton, Ed; Fazal, Muhammad Ali

    2013-01-01

    Nonunion of an isolated undisplaced cuboid fracture is unusual. We report a case of symptomatic nonunion of an isolated cuboid fracture after nonoperative treatment. Fracture union was achieved with surgery, and the patient returned to full activities.

  10. Application of monorail fixator for femoral gap nonunion

    Directory of Open Access Journals (Sweden)

    Agrawal Hemendra Kumar

    2014-07-01

    Full Text Available 【Abstract】Difficult femoral nonunion takes account of infective nonunion and aseptic gap nonunion. Limb length discrepancy and nonunion need to be tackled simultaneously. Conventionally Ilizarov ring fixator is in vogue but it has some limitations. To overcome these, monorail fixator is an effective alternative. Persistent good results can be obtained if we can get a perfect anatomical alignment and good regeneration. Key words: Femur; Ilizarov technique; External fixators

  11. Diaphyseal long bone nonunions - types, aetiology, economics, and treatment recommendations.

    Science.gov (United States)

    Rupp, Markus; Biehl, Christoph; Budak, Matthäus; Thormann, Ulrich; Heiss, Christian; Alt, Volker

    2018-02-01

    The intention of the current article is to review the epidemiology with related socioeconomic costs, pathophysiology, and treatment options for diaphyseal long bone delayed unions and nonunions. Diaphyseal nonunions in the tibia and in the femur are estimated to occur 4.6-8% after modern intramedullary nailing of closed fractures with an even much higher risk in open fractures. There is a high socioeconomic burden for long bone nonunions mainly driven by indirect costs, such as productivity losses due to long treatment duration. The classic classification of Weber and Cech of the 1970s is based on the underlying biological aspect of the nonunion differentiating between "vital" (hypertrophic) and "avital" (hypo-/atrophic) nonunions, and can still be considered to represent the basis for basic evaluation of nonunions. The "diamond concept" units biomechanical and biological aspects and provides the pre-requisites for successful bone healing in nonunions. For humeral diaphyseal shaft nonunions, excellent results for augmentation plating were reported. In atrophic humeral shaft nonunions, compression plating with stimulation of bone healing by bone grafting or BMPs seem to be the best option. For femoral and tibial diaphyseal shaft fractures, dynamization of the nail is an atraumatic, effective, and cheap surgical possibility to achieve bony consolidation, particularly in delayed nonunions before 24 weeks after initial surgery. In established hypertrophic nonunions in the tibia and femur, biomechanical stability should be addressed by augmentation plating or exchange nailing. Hypotrophic or atrophic nonunions require additional biological stimulation of bone healing for augmentation plating.

  12. Proximal femoral fractures.

    Science.gov (United States)

    Webb, Lawrence X

    2002-01-01

    Fractures of the proximal femur include fractures of the head, neck, intertrochanteric, and subtrochanteric regions. Head fractures commonly accompany dislocations. Neck fractures and intertrochanteric fractures occur with greatest frequency in elderly patients with a low bone mineral density and are produced by low-energy mechanisms. Subtrochanteric fractures occur in a predominantly strong cortical osseous region which is exposed to large compressive stresses. Implants used to address these fractures must be able to accommodate significant loads while the fractures consolidate. Complications secondary to these injuries produce significant morbidity and include infection, nonunion, malunion, decubitus ulcers, fat emboli, deep venous thrombosis, pulmonary embolus, pneumonia, myocardial infarction, stroke, and death.

  13. Reconstruction with distraction osteogenesis for juxta-articular nonunions with bone loss.

    Science.gov (United States)

    Kabata, Tamon; Tsuchiya, Hiroyuki; Sakurakichi, Keisuke; Yamashiro, Teruhisa; Watanabe, Koji; Tomita, Kasuro

    2005-06-01

    Nonunions of a juxta-articular lesion with bone loss, which represent a challenging therapeutic problem, were treated using external fixation and distraction osteogenesis. Seven juxta-articular nonunions (five septic and two aseptic) were treated. The location of the nonunion was the distal femur in four patients, the proximal tibia in one patient, and the distal tibia in two patients. All of them were located within 5 cm from the affected joints. Preoperative limb shortening was present in six cases, averaging 2.9 cm (range, 1-7 cm). The reconstructive procedure consisted of refreshment of the nonunion site, deformity correction, stabilization by external fixation, and lengthening to eliminate leg length discrepancy or to fill the defect. Shortening-distraction was applied to six patients and bone transport to one patient for reconstruction. Intramedullary nailing to reduce the duration of external fixation was simultaneously performed in two cases. All the patients had at least 1 year of follow-up evaluation. Osseous union without angular deformity or leg length discrepancy greater than 1 cm was achieved in all patients. The mean amount of lengthening was 5.8 cm (range, 2.2-10.0 cm). The mean external fixation period was 219 days (range, 98-317 days), and the mean external fixation index was 34.4 days/cm (range, 24.5-47.6 days/cm). All patients reported excellent pain reduction. There were no recurrences of infection in five patients with prior history of osteomyelitis. The functional results were categorized as excellent in two, good in three, and fair in two. Despite the length of postoperative external fixation, distraction osteogenesis can be a valuable alternative for the treatment of juxta-articular nonunions.

  14. Angular Stable Miniplate Fixation of Chronic Unstable Scaphoid Nonunion.

    Science.gov (United States)

    Schormans, Philip M J; Brink, Peter R G; Poeze, Martijn; Hannemann, Pascal F W

    2018-02-01

    Background  Around 5 to 15% of all scaphoid fractures result in nonunion. Treatment of long-lasting scaphoid nonunion remains a challenge for the treating surgeon. Healing of scaphoid nonunion is essential for prevention of scaphoid nonunion advanced collapse and the subsequent predictable pattern of radiocarpal osteoarthritis. Purpose  The purpose of this study was to investigate the feasibility of fixation of the scaphoid nonunion with a volar angular stable miniplate and cancellous bone grafting. We hypothesized that this technique could be successful, even in patients with previous surgery for nonunion and in patients with a long duration of nonunion. Patients and Methods  A total of 21 patients enrolled in a single-center prospective cohort study. Healing of nonunion was assessed on multiplanar computed tomography scan of the wrist at a 3-month interval. Functional outcome was assessed by measuring grip strength, range of motion, and by means of the patient-rated wrist and hand evaluation (PRWHE) questionnaire. Results  During follow-up, 19 out of 21 patients (90%) showed radiological healing of the nonunion. The range of motion did not improve significantly. Postoperative PRWHE scores decreased by 34 points. Healing occurred regardless of the length of time of the nonunion (range: 6-183 months) and regardless of previous surgery (38% of patients). Conclusion  Volar angular stable miniplate fixation with autologous cancellous bone grafting is a successful technique for the treatment of chronic unstable scaphoid nonunion, even in patients with long-lasting nonunion and in patients who underwent previous surgery for a scaphoid fracture. Rotational interfragmentary stability might be an important determining factor for the successful treatment of unstable scaphoid nonunion. Level of Evidence  Level IV.

  15. What is the Optimal Treatment of Atrophic Scaphoid Non-Union?

    Directory of Open Access Journals (Sweden)

    Alper Cirakli

    2016-09-01

    Full Text Available Aim: To evaluate the efficacy of the treatment method of autogenous iliac wing or radius bone graft and fixation with screw applied to cases of scaphoid non-union. Material and Method: A retrospective evaluation was made of 89 cases between 2000 and 2014. Postoperative measurements were taken of both wrists%u2019 movement with a goniometer and muscle strength was assessed with a dynamometer. Fractures were evaluated radiologically according to the Herbert-Fisher System and the functional results according to the Herbert-Fisher Classification System and the Mayo Clinic Modified Wrist Scoring System. The data were input to the SPSS system and evaluated with the Shapiro-Wilk test. Results: Non-union were on the right side in 47 and the left side in 42 cases. The fracture was seen to be in the waist in 60 cases (67.5%, in the proximal third in 27 cases (30.3% and in the distal third in two cases (2.2%. The mean follow-up period was 16.4 months (range, 5-72 months. Definitive findings of union were observed in 71 cases. The mean time to union was 14.9 weeks (range, 8-40 weeks. Discussion: The grafting procedure applied is an invasive technique but if it is considered that there are negative effects of open surgery on the feeding of the scaphoid bone, then in the treatment of scaphoid non-union which is atrophic non-union, ultimately autogenous bone grafting and screw fixation is a safe and successful method and because of the pain created by an iliac wing graft, radius distal bone graft can be considered more appropriate.

  16. The Comparison Of Results For The Bone Grafting In Treatment Of Scaphoid Nonunion With And Without Avascular Necrosis

    Directory of Open Access Journals (Sweden)

    Iman Qomashi

    2011-02-01

    Full Text Available Background: The varieties of treatment methods for the scaphoid nonunion have always been a discussable issue for orthopaedic surgeons. The current study, considered to be review for treatment results of the patients who sustained the scaphoid nonunion with or without avascular necrosis and compared these two groups clinically and radiologically. Methods: The clinical and radiologic files of the patients who sustained the scaphoid nonunion and underwent surgical treatment between 2004 and 2009 in our hospital, were collected and in the final follow-up, 37 patients and 38 nonunions underwent physical exam, grip power test, DASH questionnaire and radiography. Results: Avascular necrosis was detected in 22 cases and 16 cases had no avascular necrosis changes. Following open reduction and bone grafing, union was seen in 36 cases, and nonunion in 2 cases which one was in the avascular necrosis group and another in without avascular necrosis group. The comparison of the residual pain, range of motion, DASH score and grip power in two groups, did not show a meaningful difference (p>0.05. Conclusion: Although multiple studies indicated that in the presence of the avascular necrosis in the proximal fragment of the scaphiod, possibility of union in the conventional graft methods was lower than vascular pedicle grafts, but this study demonstrated that the conventional treatment method yet was associated with a considerable successs and a reliable treatment method.

  17. Nonunion of acetabular fractures: evaluation with interactive multiplanar CT

    International Nuclear Information System (INIS)

    Kuhlman, J.E.; Fishman, E.K.; Ney, D.R.; Brooker, A.F. Jr.; Magid, D.

    1989-01-01

    Nonunions involving fractures of the acetabulum are reportedly rare, with few citings and little discussion in the literature. It is possible that acetabular nonunions go undetected because imaging of the acetabulum is difficult by conventional radiography. We report two cases of fracture nonunion involving the weight-bearing surface of the acetabulum diagnosed with the aid of computed tomography (CT) and a newly developed interactive 2D/3D orthotool that uniquely processes and reformats routine CT data. The interactive 2D/3D orthotool is a sophisticated computer program that allows dynamic viewing of standard multiplanar reconstructions in the axial, coronal, and sagittal planes as well as multiple oblique projections. The 2D/3D orthotool provides on screen correlation of two-dimensional multiplanar images with three-dimensional reconstructions of the pelvis. The authors found this capability ideally suited for studying fractures with off-axis orientation such as those through the acetabular dome, greatly facilitating the diagnosis of nonunion

  18. Effectiveness of plate augmentation for femoral shaft nonunion after nailing

    Directory of Open Access Journals (Sweden)

    Chin-Jung Lin

    2012-08-01

    Conclusion: Plate augmentation with retention of the nail with autologous bone grafting may be an effective and reliable alternative in treating nonunion of the femoral shaft fracture after open reduction and internal fixation with intramedullary nail.

  19. Successful treatment of recalcitrant nonunions with combined magnetic field stimulation.

    Science.gov (United States)

    Longo, J A

    1997-01-01

    Nonunions and delayed unions have been classically defined by Bassett as an arrest of the fracture healing process at an intermediary stage of repair, at which time the fracture gap is bridged by fibrocartilage. It is estimated that approximately 10-20 % of long bone fractures in the United States will result in delayed unions when compared to the average rate of healing for the location and type of fracture. Many of these will go on to a nonunion if biological or biomechanical factors are not optimized to enhance healing. Additional commorbities such as smoking, ethanol abuse, malnutrition, malabsorption and altered neurologic conditions can contribute to delayed unions or nonunions. Even despite appropriate and aggressive early management of long bone fractures, a certain percentage still lack progression of healing and go on to nonunion. Classical surgical management of nonunions includes obtaininjg fracture stabilization with ORIF techniques and bone grafting, with reported clinical successes ranging from 50-80%. Those that fail to achieve union despite classical management are indeed recalcitrant nonunions.

  20. Surgical treatment of rib fracture nonunion: A single center experience.

    Science.gov (United States)

    de Jong, M B; Houwert, R M; van Heerde, S; de Steenwinkel, M; Hietbrink, F; Leenen, L P H

    2018-03-01

    In contrast to the emerging evidence on the operative treatment of flail chest, there is a paucity of literature on the surgical treatment of rib fracture nonunion. The purpose of this study was to describe our standardized approach and report the outcome (e.g. patient satisfaction, pain and complications) after surgical treatment of a rib fracture nonunion. A single centre retrospective cohort study was performed at a level 1 trauma centre. Symptomatic rib nonunion was defined as a severe persistent localized pain associated with the nonunion of one or more rib fractures on a chest CT scan at least 3 months after the initial trauma. Patients after initial operative treatment of rib fractures were excluded. Nineteen patients (11 men, 8 women), with symptomatic nonunions were included. Fourteen patients were referred from other hospitals and 8 patients received treatment from a pain medicine specialist. The mean follow-up was 36 months. No in-hospital complications were observed. In 2 patients, new fractures adjacent to the implant, without new trauma were observed. Furthermore 3 patients requested implant removal with a persistent nonunion in one patient. There was a mean follow-up of 36 months, the majority of patients (n = 13) were satisfied with the results of their surgical treatment and all patients experienced a reduction in the number of complaints. Persisting pain was a common complaint. Three patients reporting severe pain used opioid analgesics on a daily or weekly basis. Only 1 patient needed ongoing treatment by a pain medicine specialist. Surgical fixation of symptomatic rib nonunion is a safe and feasible procedure, with a low perioperative complication rate, and might be beneficial in selected symptomatic patients in the future. In our study, although the majority of patients were satisfied and the pain level subjectively decreases, complaints of persistent pain were common. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Risk profile of patients developing nonunion of the clavicle and outcome of treatment

    DEFF Research Database (Denmark)

    Ban, Ilija; Troelsen, Anders

    2016-01-01

    PURPOSE: The most common complication following treatment of a clavicle fracture is nonunion. Most nonunions are symptomatic and treatment is mostly operative. The aim of this study was to describe risk profiles of patients developing nonunion and what outcome is observed following operative...... of functionality and patient reported satisfaction and remission of symptoms was done a minimum of six months post-operatively by mail. Response rate was 60%. RESULTS: The overall nonunion rate was 7.5%. Nine nonunions were initially treated operatively. Risk factors associated with nonunion of our series...

  2. Magnet pole tips

    Science.gov (United States)

    Thorn, Craig E.; Chasman, Chellis; Baltz, Anthony J.

    1984-04-24

    An improved magnet which more easily provides a radially increasing magnetic field, as well as reduced fringe field and requires less power for a given field intensity. The subject invention comprises a pair of spaced, opposed magnetic poles which further comprise a pair of pole roots, each having a pole tip attached to its center. The pole tips define the gap between the magnetic poles and at least a portion of each pole tip is separated from its associated pole root. The separation begins at a predetermined distance from the center of the pole root and increases with increasing radial distance while being constant with azimuth within that portion. Magnets in accordance with the subject invention have been found to be particularly advantageous for use in large isochronous cyclotrons.

  3. Anterior versus posterior approach in reconstruction of infected nonunion of the tibia using the vascularized fibular graft: potentialities and limitations.

    Science.gov (United States)

    Amr, Sherif M; El-Mofty, Aly O; Amin, Sherif N

    2002-01-01

    The potentialities, limitations, and technical pitfalls of the vascularized fibular grafting in infected nonunions of the tibia are outlined on the basis of 14 patients approached anteriorly or posteriorly. An infected nonunion of the tibia together with a large exposed area over the shin of the tibia is better approached anteriorly. The anastomosis is placed in an end-to-end or end-to-side fashion onto the anterior tibial vessels. To locate the site of the nonunion, the tibialis anterior muscle should be retracted laterally and the proximal and distal ends of the site of the nonunion debrided up to healthy bleeding bone. All the scarred skin over the anterior tibia should be excised, because it becomes devitalized as a result of the exposure. To cover the exposed area, the fibula has to be harvested with a large skin paddle, incorporating the first septocutaneous branch originating from the peroneal vessels before they gain the upper end of the flexor hallucis longus muscle. A disadvantage of harvesting the free fibula together with a skin paddle is that its pedicle is short. The skin paddle lies at the antimesenteric border of the graft, the site of incising and stripping the periosteum. In addition, it has to be sutured to the skin at the recipient site, so the soft tissues (together with the peroneal vessels), cannot be stripped off the graft to prolong its pedicle. Vein grafts should be resorted to, if the pedicle does not reach a healthy segment of the anterior tibial vessels. Defects with limited exposed areas of skin, especially in questionable patency of the vessels of the leg, require primarily a fibula with a long pedicle that could easily reach the popliteal vessels and are thus better approached posteriorly. In this approach, the site of the nonunion is exposed medial to the flexor digitorum muscle and the proximal and distal ends of the site of the nonunion debrided up to healthy bleeding bone. No attempt should be made to strip the scarred skin off

  4. Management of infected non-union tibia by intercalary bone transport

    International Nuclear Information System (INIS)

    Pirwani, M.A.; Siddiqui, A.; Soomro, Y.H.

    2008-01-01

    To evaluate the efficacy of ilizarov ring fixator in treating infected non-union tibia by intercalary bone transport. Sixteen patients, all males, aged 20-60 years (mean 32 years), with infected non-union tibia (Lax/Cierney Type IV Osteomyelitis); the commonest cause being open fracture and the commonest site being lower 1/3rd. In infected non-union of tibia with draining sinus, wound swab was sent for culture and sensitivity, and sinogram done. Debridement and sequestrectomy was done, leaving behind a gap ranging from 2-8 cms (mean 4.5 cms) and ilizarov ring fixator, a transport assembly, applied. A navigation wire was passed through medial malleolus, irrigation system set up and the wound closed in a single layer. Proximal metaphyseal corticotomy was done. Irrigation with 2-3 litres of normal saline with appropriate antibiotic was continued for five days. On the 5th day irrigation system was removed and the transport started. Patients remained on partial weight bearing till soft tissue healing occured. Transport took place over the navigation wire at the rate of 1mm/day till docking achieved. Full weight bearing was allowed after soft tissue healing; knee and ankle physiotherapy was started from day one. Navigation wire was removed after 2-3 weeks of docking. Follow up ranged from 12-27 months (mean 16 months). Union was achieved at the docking site in all the cases at the time of frame removal i.e. 8-13 months. The duration of union at docking site ranged from 3.5 months to 6 months (mean 4.5 months). Two patients needed bone graft at the docking site. The regenerate was broken in one case due to fall which was treated in cast. All the patients were satisfied except a 60 years old who had severe osteoarthritis of knee. Pin tract infection occurred on and off in all the patients; appropriate antibiotic was given. The infection subsided in all the cases except two in whom debridement was followed by application of a local flap. Intercalary bone transport by

  5. Stress Fracture and Nonunion of Coronoid Process in a Gymnast

    Directory of Open Access Journals (Sweden)

    T. Hetling

    2016-01-01

    Full Text Available Background. Gymnasts have high mechanical loading forces of up to 14 times body weight. Overuse lesions are typical in wrists and stress fractures in the olecranon, while isolated fractures of the coronoid process are uncommon. We present a case of retraumatized nonunion stress fracture of the ulnar coronoid process. Case Description. A 19-year-old gymnast presented with elbow pain after training. Imaging confirmed an old fracture of the coronoid process. We describe a 6-month multiphase return to competition rehabilitation program, which allowed him to compete pain-freely. Literature Review. Acute and overuse injuries in gymnasts are known but no nonunion of the coronoid process has been described before. Only one case of stress fracture of coronoid process in a gymnast was reported. Purpose and Clinical Relevance. We could successfully and conservatively return to sport a reactivated nonunion of a stress fracture of the coronoid process.

  6. The treatment of nonisthmal femoral shaft nonunions with im nail exchange versus augmentation plating.

    Science.gov (United States)

    Park, Jin; Kim, Sul Gee; Yoon, Han Kook; Yang, Kyu Hyun

    2010-02-01

    The purpose of this study was to compare the results between exchange nailing (EN) and augmentation plating (AP) with a nail left in situ for nonisthmal femoral shaft nonunion after femoral nailing. : Retrospective data analysis, November 1996-March 2006. A level I trauma center. Eighteen patients with 18 nonisthmal femoral nonunions. Seven patients with 7 fractures treated for nonisthmal femoral shaft nonunions after femoral nailing with EN and 11 patients with 11 fractures treated for nonisthmal femoral shaft nonunions after nailing with AP combined with bone grafting. Union and complications. Five nonunions in the EN group failed to achieve union (72% failure rate), whereas all 11 pseudarthroses in the AP group obtained osseous union. Fisher exact test showed a higher nonunion rate of EN compared with AP for nonisthmal femoral shaft nonunion (odds ratio, 6.5; P = 0.002). AP with autogenous bone grafting may be a better option than EN for nonisthmal femoral nonunions.

  7. Rhodotorula mucilaginosa as a cause of persistent femoral nonunion

    Directory of Open Access Journals (Sweden)

    Goyal R

    2008-01-01

    Full Text Available We present a case of postoperative infection which presented as nonunion fracture femur in a 30-year-old man due to Rhodotorula mucilaginosa . This is the first report of Rhodotorula infection in a patient with fracture nonunion. The patient underwent repeated surgical debridement and received intensive antibiotic therapy before the diagnosis was made. The diagnosis could have been made earlier if the fungal etiology had been suspected earlier. Early suspicion and diagnosis of infection with atypical yeasts could be under-reported because of difficulties in accurate diagnosis and a tendency of attributing isolates to specimen contamination.

  8. Non-Anatomical Surgical Solutions for Difficult Non-Unions: Case Series

    OpenAIRE

    Zaki Said, Galal; Farouk, Osama Ahmed; Galal Said, Hatem; Mohamed El-Sharkawi, Mohamed Mostafa

    2013-01-01

    Abstract Non-union occurs when bone healing ceases and does not continue without some type of intervention. Classification of non-union is traditionally based on the amount of callus or bone healing at the fracture site. Successful treatment of non-union often depends on appropriate reduction and realignment of the fracture, bone grafting if necessary, and stabilization. This may not be possible in some neglected and complicated non-unions. Under these circumstances, modification of the stand...

  9. Poling of Planar Silica Waveguides

    DEFF Research Database (Denmark)

    Arentoft, Jesper; Kristensen, Martin; Jensen, Jesper Bo

    1999-01-01

    UV-written planar silica waveguides are poled using two different poling techniques, thermal poling and UV-poling. Thermal poling induces an electro-optic coefficient of 0.067 pm/V. We also demonstrate simultaneous UV-writing and UV-poling. The induced electro-optic effect shows a linear dependence...

  10. Atrophic femoral nonunion with bone loss: treatment with monorail transport: a case report.

    Science.gov (United States)

    Gay, David M; Voss, Frank R

    2004-08-01

    Nonunions are an uncommon outcome of femoral fractures. Atrophic nonunions with a leg length discrepancy secondary to bone loss are often the most difficult to treat, and the treatment options are limited. We present a case that uses concomitant monolateral external fixation and intramedullary nailing to heal a nonunion and perform a simultaneous 7-cm lengthening procedure in a 33-year-old female.

  11. Outcome of Management of Humerus Diaphysis Non-union This ...

    African Journals Online (AJOL)

    jen

    patients with nonunion of the humeral diaphysis were reviewed. ... 3 failures occurred of whom one was a smoker and diabetic, another had a loose ... as absence of radiographic signs of union and persistent pain on clinical ... Elbow Surgeons (ASES) Score for 13 activities of daily living 9 requiring full shoulder and elbow.

  12. Treatment of Atrophic Nonunion - A Report of Two Cases | Omeonu ...

    African Journals Online (AJOL)

    RESULT: Long periods of limb immobilization in traditional fracture treatment often result to ... or nail do not give rigid fixation due to bone softening and often result to serial nonunion. ... a bloodless transformation of bone callus which avoids exposure of fracture site and soft tissue stripping is best suited for treating infected ...

  13. Three-stage treatment protocol for recalcitrant distal femoral nonunion.

    Science.gov (United States)

    Ma, Ching-Hou; Chiu, Yen-Chun; Tu, Yuan-Kun; Yen, Cheng-Yo; Wu, Chin-Hsien

    2017-04-01

    In this study, we proposed a three-stage treatment protocol for recalcitrant distal femoral nonunion and aimed to analyze the clinical results. We retrospective reviewed 12 consecutive patients with recalcitrant distal femoral nonunion undergoing our three-stage treatment protocol from January 2010 to December 2014 in our institute. The three-stage treatment protocol comprised debridement of the nonunion site, lengthening to eliminate leg length discrepancy, deformity correction, stabilization with a locked plate, filling of the defect with cement spacer for inducing membrane formation, and bone reconstruction using a cancellous bone autograft (Masquelet technique) or free vascularized fibular bone graft. The bone union time, wound complication, lower limbs alignment, amount of lengthening, knee range of motion, and functional outcomes were evaluated. Osseous union with angular deformity lengthening was 5.88 cm (range 3.5-12 cm). Excellent or good outcomes were obtained in 9 patients. Although the current study involved only a small number of patients and the intervention comprised three stages, we believe that such a protocol may be a valuable alternative for the treatment of recalcitrant distal femoral nonunion.

  14. Can we trust intraoperative culture results in nonunions?

    Science.gov (United States)

    Palmer, Michael P; Altman, Daniel T; Altman, Gregory T; Sewecke, Jeffrey J; Ehrlich, Garth D; Hu, Fen Z; Nistico, Laura; Melton-Kreft, Rachel; Gause, Trent M; Costerton, John W

    2014-07-01

    To identify the presence of bacterial biofilms in nonunions comparing molecular techniques (multiplex polymerase chain reaction and mass spectrometry, fluorescent in situ hybridization) with routine intraoperative cultures. Thirty-four patients with nonunions were scheduled for surgery and enrolled in this ongoing prospective study. Intraoperative specimens were collected from removed implants, surrounding tissue membrane, and local soft tissue followed by standard culture analysis, Ibis's second generation molecular diagnostics (Ibis Biosystems), and bacterial 16S rRNA-based fluorescence in situ hybridization (FISH). Confocal microscopy was used to visualize the tissue specimens reacted with the FISH probes, which were chosen based on the Ibis analysis. Thirty-four patient encounters were analyzed. Eight were diagnosed as infected nonunions by positive intraoperative culture results. Ibis confirmed the presence of bacteria in all 8 samples. Ibis identified bacteria in a total of 30 of 34 encounters, and these data were confirmed by FISH. Twenty-two of 30 Ibis-positive samples were culture-negative. Four samples were negative by all methods of analysis. No samples were positive by culture, but negative by molecular techniques. Our preliminary data indicate that molecular diagnostics are more sensitive for identifying bacteria than cultures in cases of bony nonunion. This is likely because of the inability of cultures to detect biofilms and bacteria previously exposed to antibiotic therapy. Diagnostic Level I. See Instructions for Authors for a complete description of levels of evidence.

  15. Effects of third fragment size and displacement on non-union of femoral shaft fractures after locking for intramedullary nailing.

    Science.gov (United States)

    Lee, J R; Kim, H-J; Lee, K-B

    2016-04-01

    The femoral shaft fractures with large fragments makes anatomical reduction challenging and often results in non-union. In some studies, the degree of fragment displacement was reported to have affected non-union, but the association between the one fragment size and degree of displacement has not been fully clarified. Therefore we performed a retrospective study to assess: (1) the more influential factor of non-union: the degree of fragment displacement, or the fragment size? (2) the non-union rates according to different sizes and degrees of displacement. The degree of displacement is the more potent factor of non-union than the third fragment size in femoral shaft fractures. We assessed retrospectively 64 cases, which could be followed up for longer than one year. Fragments were divided according to the length of their long axis into three groups: group A (0-3.9cm), (n=21); group B (4-7.9cm), (n=22); group C (8cm or more), (n=21). Fragment displacement was also assessed in the proximal (P) or distal (D) end to the nearest cortex of the femoral shaft, and divided into the following groups: group P1 (n=44) or D1 (n=47), (0-9mm); group P2 (n=10) or D2 (n=11), (10-19mm); group P3 (n=7) or D3 (n=3), (20-29mm); and group P4 (n=3) or D4 (n=3), (30mm or more). The bone union rate was 86% in the small (less than 8cm) fragment groups and 71% in the large (8cm or more) fragment group (P=0.046). With respect to the degree of displacement, the union rate was lower (P=0.001) and the average union time was longer (P=0.012) in the 20mm or more group for both the proximal fragment part and the distal fragment part (P=0.002, P=0.014). A logistic regression analysis underlined the displacement in the proximal site (OR: 0.298, 95% CI: 0.118-0.750) as in the distal site (OR: 0.359, 95% CI: 0.162-0.793) as a larger effect on union rate than the fragment size that as no effect in logistic regression (OR 3.8, 95% CI: 0.669-21.6). Non-union develops significantly more frequently in

  16. Outcomes after operative management of symptomatic rib nonunion.

    Science.gov (United States)

    Gauger, Erich M; Hill, Brian W; Lafferty, Paul M; Cole, Peter A

    2015-06-01

    To report the outcomes of rib reconstruction after painful nonunion. Retrospective case series. Level I trauma center. Between November 2007 and May 2013, 10 patients who presented with 16 rib nonunions and disabling pain were treated with reconstruction of their nonunited rib fractures. Rib nonunion reconstruction predominately with iliac crest bone graft and a tension band plate with a locked precontoured plating system for ribs. Demographic data, mechanism of injury, and number of rib nonunions were recorded. Operative procedure, length of follow-up, complications, Short Form Survey 36, and a patient questionnaire were also captured and documented. Eight of the 10 patients sustained their original fractures from a fall. Outcomes were available for the 10 patients at a mean follow-up of up of 18.6 months (range, 3-46 months). All 16 ribs went on to union with a mean time from reconstruction to union of 14.7 weeks (range, 12-24 weeks). At final follow-up, the mean mental and physical component Short Form Survey 36 scores were 54.4 and 43.5, respectively. Eight of the 10 patients were able to return to work and/or previous activities without limitations. Complications included 1 wound infection that resolved after irrigation and debridement with adjunctive antibiotics. One symptomatic implant was removed. Ten patients with 16 symptomatic rib nonunions were reconstructed using autologous bone graft and implant/mesh fixation manifesting in successful union with improved patient function and a low rate of complications. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  17. Management of complex long bone nonunions using limb reconstruction system

    Directory of Open Access Journals (Sweden)

    Hiranya Kumar Seenappa

    2013-01-01

    Full Text Available Background: Management of complex nonunions is difficult due to the presence of infection, deformities, shortening and multiple surgeries in the past. Complex nonunions are traditionally managed by Ilizarov fixation. The disadvantages of Ilizarov are poor patient compliance, inconvenience of the frame and difficult frame construction. We conducted a study on 30 long bone complex nonunions treated by the limb reconstruction system (LRS. Materials and Methods: Between April 2009 and September 2012, we treated 30 cases of complex nonunion of long bone with the LRS. 28 were male and 2 females. Average shortening was 5.06 cm and 14 cases presented with infected implants. Initially we managed with implant removal, radical debridement followed by fixation with the LRS. In 16 cases, corticotomy and lengthening was done. The average duration of treatment was 9.68 months. We compressed the fracture site at the rate of 0.25 mm per day for 1-2 weeks and distracted the corticotomy at the rate of 1 mm/day till lengthening was achieved. Result: The union occurred in 89.28% cases and eradication of infection in 91.66% cases. Average lengthening done was 4.57 cm. We had 79% excellent, 11% good and 10% poor bony result and fnctional result was excellent in 40% cases, good in 50% and failure in 10% cases using ASAMI scoring system. Conclusion: LRS is an alternative to the Ilizarov fixation in their management of complex nonunion of long bones. It is less cumbersome to the patient and more surgeon and patient friendly.

  18. Ipsilateral proximal femur and shaft fractures treated with hip screws and a reamed retrograde intramedullary nail.

    Science.gov (United States)

    Ostrum, Robert F; Tornetta, Paul; Watson, J Tracy; Christiano, Anthony; Vafek, Emily

    2014-09-01

    Although not common, proximal femoral fractures associated with ipsilateral shaft fractures present a difficult management problem. A variety of surgical options have been employed with varying results. We investigated the use of hip screws and a reamed retrograde intramedullary (IM) nail for the treatment of this combined fracture pattern in terms of postoperative alignment (malunion), nonunion, and complications. Between May 2002 and October 2011, a total of 95 proximal femoral fractures with associated shaft fractures were treated at three participating Level 1 trauma centers; all were treated with hip screw fixation (cannulated screws or sliding hip screws) and retrograde reamed IM nails. The medical records of these patients were reviewed retrospectively for alignment, malunion, nonunion, and complications. Followup was available on 92 of 95 (97%) of the patients treated with hip screws and a retrograde nail. Forty were treated with a sliding hip screw, and 52 were treated with cannulated screws. There were five proximal malunions in this series (5%). The union rate was 98% (90 of 92) for the femoral neck fractures and 91.3% (84 of 92) for the femoral shaft fractures after the initial surgery. There were two nonunions of comminuted femoral neck fractures after cannulated screw fixation. There was no difference in femoral neck union or alignment when comparing cannulated screws to a sliding hip screw. Four open comminuted femoral shaft fractures went on to nonunion and required secondary surgery to obtain union, and one patient developed symptomatic avascular necrosis. The treatment of ipsilateral proximal femoral neck and shaft fractures with hip screw fixation and a reamed retrograde nail demonstrated a high likelihood of union for the femoral neck fractures and a low risk of malunion. Comminution and initial displacement of the proximal femoral fracture may still lead to a small incidence of malunion or nonunion, and open comminuted femoral shaft fractures

  19. Management of diabetic neuropathic foot and ankle malunions and nonunions

    Directory of Open Access Journals (Sweden)

    John J. Stapleton

    2011-05-01

    Full Text Available The management of diabetic neuropathic foot and ankle malunions and/or nonunions is often complicated by the presence of broken or loosened hardware, Charcot joints, infection, osteomyelitis, avascular bone necrosis, unstable deformities, bone loss, disuse and pathologic osteopenia, and ulcerations. The author discusses a rational approach to functional limb salvage with various surgical techniques that are aimed at achieving anatomic alignment, long-term osseous stability, and adequate soft tissue coverage. Emphasis is placed on techniques to overcome the inherent challenges that are encountered when surgically managing a diabetic nonunion and/or malunion. Particular attention is directed to the management of deep infection and Charcot neuroarthropathy in the majority of the cases presented.

  20. Hydatid disease: A rare cause of fracture nonunion

    Directory of Open Access Journals (Sweden)

    Divya Aggarwal

    2017-01-01

    Full Text Available Hydatid disease is an infrequent parasitic infestation caused by cestode, most commonly, Echinococcus granulosus. Bone involvement is distinctly uncommon. We would like to share our experience of a rare case of hydatid disease of femur in a 24-year-old male who presented with nonunion of subtrochanteric fracture. Histopathology showed typical lamellated wall and dagger-shaped hooklets. In view of its rarity, hydatid disease often remains an unsuspected infection of the bone.

  1. Force interaction and 3D pole movement in double poling.

    Science.gov (United States)

    Stöggl, T; Holmberg, H-C

    2011-12-01

    The aim of this study was to analyze double poling using combined kinetic and 3D kinematic analysis at high skiing speeds as regards pole force components, pole angles and pole behavior during the poling and swing phase. The hypothesis was that a horizontal pole force is more predictive for maximal skiing speed (V(max)) than the resultant pole force. Sixteen elite skiers performed a double-poling V(max) test while treadmill roller skiing. Pole forces and 3D kinematics of pole movement at a speed of 30 km/h were analyzed and related to V(max). The duration of the "preparation phase" showed the strongest relationship with V(max) (r=0.87, Pmax) compared with the resultant pole force. Impact force was not related to V(max). At high skiing speeds, skiers should aim to combine high pole forces with appropriate timing of pole forces and appropriate pole and body positions during the swing and poling phase. The emphasis in training should be on the development of specific strength capacities for pole force production and the utilization of these capacities in double-poling training sessions. © 2011 John Wiley & Sons A/S.

  2. Sacral Fracture Nonunion Treated by Bone Grafting through a Posterior Approach

    Directory of Open Access Journals (Sweden)

    Sang Yang Lee

    2013-01-01

    Full Text Available Nonunion of a sacral fracture is a rare but serious clinical condition which can cause severe chronic pain, discomfort while sitting, and significant restriction of the level of activities. Fracture nonunions reportedly occur most often after nonoperative initial treatment or inappropriate operative treatment. We report a case of fracture nonunion of the sacrum and pubic rami that resulted from non-operative initial treatment, which was treated successfully using bone grafting through a posterior approach and CT-guided percutaneous iliosacral screw fixation combined with anterior external fixation. Although autologous bone grafting has been the gold standard for the treatment of pelvic fracture nonunions, little has been written describing the approach. We utilized a posterior approach for bone grafting, which could allow direct visualization of the nonunion site and preclude nerve root injury. By this procedure, we were able to obtain the healing of fracture nonunion, leading to pain relief and functional recovery.

  3. Proximal Humerus

    NARCIS (Netherlands)

    Diercks, Ron L.; Bain, Gregory; Itoi, Eiji; Di Giacomo, Giovanni; Sugaya, Hiroyuki

    2015-01-01

    This chapter describes the bony structures of the proximal humerus. The proximal humerus is often regarded as consisting of four parts, which assists in understanding function and, more specially, describes the essential parts in reconstruction after fracture or in joint replacement. These are the

  4. Economic burden of illness among US patients experiencing fracture nonunion

    Directory of Open Access Journals (Sweden)

    Wu N

    2013-03-01

    Full Text Available Ning Wu,1 Yuan-chi Lee,1 Daniel Segina,2 Hallie Murray,3 Teresa Wilcox,1 Luke Boulanger1 1United BioSource Corporation, Lexington, MA, USA; 2Department of Orthopaedics, Holmes Regional Trauma Center, Melbourne, FL, USA; 3Biomet Spine and Bone Healing Technologies, Parsippany, NJ, USA Objectives: To compare economic outcomes in a real-world study of patients with fracture nonunion receiving non-invasive electrical bone growth stimulation (EBGS, low-intensity pulsed ultrasound stimulation (LIPUS, or other non-stimulation fracture management interventions (No-stim. Methods: Medical and pharmacy claims from a US commercially-insured population were analyzed to select adult patients newly diagnosed with a fracture nonunion between July 2006 and September 2009. The date of initial nonunion diagnosis was set as the index date. Three cohorts were constructed based on the first treatment prescribed post index date: EBGS, LIPUS, or No-stim. Baseline demographics, clinical characteristics, and health care costs 9 months before and 1 year after the index date were assessed. Multivariate regression analyses were performed to compare health care costs between cohorts in the post index period. Results: 11,628 patients (mean age 45.4 years; 45.7% males with a fracture nonunion were identified within the three treatment groups (EBGS: 29.5%, LIPUS: 12.3%, and No-stim: 58.2%. In the post-index period, EBGS patients were significantly less likely to receive fracture-related treatments when compared to the LIPUS (33.6% vs 42.2%, P < 0.01 and the No-stim (33.6% vs 60.3%, P < 0.01 cohorts. Additionally, after adjusting for demographic and clinical characteristics, the EBGS cohort had significantly lower predicted health care-associated costs 1 year post index date when compared to the LIPUS (mean: $21,632 vs $23,964, P < 0.01 and the No-stim (mean: $21,632 vs $23,843, P < 0.01 cohorts. Furthermore, the predicted fracture-related costs (FRC of EBGS patients were also

  5. Successful reconstruction for complex malunions and nonunions of the tibia and femur

    NARCIS (Netherlands)

    Buijze, Geert A.; Richardson, Shawn; Jupiter, Jesse B.

    2011-01-01

    Information regarding the long-term outcomes of the treatment of lower-extremity fracture malunion and nonunion is lacking. Twenty-nine secondarily referred patients with complex malunion or nonunion of the tibia or femur, treated by a single surgeon, were followed for a median of twenty years

  6. Osseous union in cases of nonunion in long bones treated by ...

    African Journals Online (AJOL)

    To determine the incidence of osseous union in cases of nonunion of long bones managed by open reduction and compression plating. : Between November, 2003 and June, 2005, 53 patients with nonunion of long bones were treated by open reduction and internal fixation and followed up. The follow up period for each ...

  7. [Treatment of postoperative nonunion of fracture of lower limb with bone grafting by intervertebral disc endoscope].

    Science.gov (United States)

    Zhang, Jianlin; Tan, Yu'e; Ye, Jun; Han, Fangmin

    2012-02-01

    To explore the effectiveness of bone grafting by intervertebral disc endoscope for postoperative nonunion of fracture of lower limb. Between August 2004 and August 2008, 40 patients (23 males and 17 females) with postoperative nonunion of femoral and tibial fracture, aged 20-63 years (mean, 41.5 years) were treated. Nonunion of fracture occurred at 10-16 months after internal fixation. During the first operation, the internal fixation included interlocking intramedullary nailing of femoral fracture in 12 cases and plate in 16 cases, and interlocking intramedullary nailing of tibial fractures in 9 cases and plate in 3 cases. The X-ray films showed hypertrophic nonunion in 24 cases, common nonunion in 3 cases, and atrophic nonunion in 13 cases. The average operation time was 61 minutes (range, 40-80 minutes), and the blood loss was 80-130 mL (mean, 100 mL). The hospitalization time were 6-11 days (mean, 8.1 days). Incisions healed by first intention in all patients with no complication of infection or neurovascular injury. Forty patients were followed up 10-16 months (mean, 12.3 months). The X-ray films showed that all patients achieved healing of fracture after 4-10 months (mean, 6.8 months). No pain, disfunction, or internal fixation failure occurred. Bone grafting by intervertebral disc endoscope is an effective method for treating postoperative nonunion of femoral and tibial fracture.

  8. A new variant of scaphoid reconstruction: Treatment of scaphoid non-union with avascular bone interponate and high compression screw (Synthes

    Directory of Open Access Journals (Sweden)

    Eder, Christian

    2015-08-01

    Full Text Available Scaphoid fractures as frequently overseen injuries often result in scaphoid non-unions, that need to be treated to prevent carpal collapse and secondary cartilage damage. Vital bone tissue and compression of fracture and bone graft ends seem to be crucial in for ossification and final bone healing. In the present study we compare our results using a high compression screw (HCS Synthes to results in the literature using different kinds of internal fixation including compression screws of various types. We present 22 patients with scaphoid non-unions treated with a bone graft and a HCS Synthes. We evaluated our post-operative results. The Manchester-Modified Disability of the Shoulder, Arm and Hand–Score (M-Dash imposed with an average of 29.8 points (MD=29 / SD=9.46 / MIN=18 / MAX=48. None of the re-evaluated patients sorrowed for pain in rest. Five patients stated pain (ranging from 4 to 8 on numeric analogue scale after heavy burden (e.g. boxing, weight lifting.In exploring the range of motion of the operated hand we deliver the following results: dorsal extension: average 72.73° (MD=80° / SD=17.23° / MIN=30° / MAX=85°, flexion: average 73.64° (MD=80° / SD=8.97° / MIN=60° / MAX=80°, ulnar deviation: average 39.09°, (MD=40° / SD=2.02° / MIN=35° / MAX=40°, radial deviation: average 29.09°, (MD=30° / SD=3.01° / MIN=20° / MAX=30°. Additionally a performance testing was conducted: fist clenching sign: complete without pain in 100%, pinch grip: complete in 100%, moderate pain in n=1 (8.33%, opposition digitus manus I–V complete in 100%, moderate pain n=2 (16.67%. Three patients with persisting fracture gap had a scaphoid bone fractured in the proximal third; one patient even with a very small proximal fragment. One persisting non-union was localized in the middle third (period between injury and operation = . In conclusion, our patients showed better healing rates compared to results presented in the literature. Non-unions

  9. Use of bone marrow derived stem cells in a fracture non-union

    Directory of Open Access Journals (Sweden)

    Binod C. Raulo

    2012-01-01

    Full Text Available This is an attempt of using in vitro cultured mesenchymal stem cells (MSCs from bone marrow in joining of a fracture non-union. Bone marrow cells were obtained and differentially centrifuged for MSCs that were grown in vitro in mesenchymal stem cell basal medium aseptically, for 10 d. The cell mass was injected around the fracture non-union. Healthy conditions of development of tissue regeneration at the trauma site and due bone joining were recorded. It is concluded that in vitro cultured MSCs had a blithesome effect on the fracture non-union.

  10. Wood pole overhead lines

    CERN Document Server

    Wareing, Brian

    2005-01-01

    This new book concentrates on the mechanical aspects of distribution wood pole lines, including live line working, environmental influences, climate change and international standards. Other topics include statutory requirements, safety, profiling, traditional and probabilistic design, weather loads, bare and covered conductors, different types of overhead systems, conductor choice, construction and maintenance. A section has also been devoted to the topic of lightning, which is one of the major sources of faults on overhead lines. The book focuses on the effects of this problem and the strate

  11. Periodically poled silicon

    Science.gov (United States)

    Hon, Nick K.; Tsia, Kevin K.; Solli, Daniel R.; Khurgin, Jacob B.; Jalali, Bahram

    2010-02-01

    Bulk centrosymmetric silicon lacks second-order optical nonlinearity χ(2) - a foundational component of nonlinear optics. Here, we propose a new class of photonic device which enables χ(2) as well as quasi-phase matching based on periodic stress fields in silicon - periodically-poled silicon (PePSi). This concept adds the periodic poling capability to silicon photonics, and allows the excellent crystal quality and advanced manufacturing capabilities of silicon to be harnessed for devices based on χ(2)) effects. The concept can also be simply achieved by having periodic arrangement of stressed thin films along a silicon waveguide. As an example of the utility, we present simulations showing that mid-wave infrared radiation can be efficiently generated through difference frequency generation from near-infrared with a conversion efficiency of 50% based on χ(2) values measurements for strained silicon reported in the literature [Jacobson et al. Nature 441, 199 (2006)]. The use of PePSi for frequency conversion can also be extended to terahertz generation. With integrated piezoelectric material, dynamically control of χ(2)nonlinearity in PePSi waveguide may also be achieved. The successful realization of PePSi based devices depends on the strength of the stress induced χ(2) in silicon. Presently, there exists a significant discrepancy in the literature between the theoretical and experimentally measured values. We present a simple theoretical model that produces result consistent with prior theoretical works and use this model to identify possible reasons for this discrepancy.

  12. Intrinsic and extrinsic risk factors for nonunion after nonoperative treatment of midshaft clavicle fractures.

    Science.gov (United States)

    Liu, W; Xiao, J; Ji, F; Xie, Y; Hao, Y

    2015-04-01

    The optimal treatment of midshaft clavicle fractures remains controversial. Nonunion is usually considered to be an uncommon complication following a nonoperatively treated clavicle fracture. Not every midshaft clavicular fractures shares the same risk of developing nonunion after nonoperative treatment. The present study was performed to identify the intrinsic and extrinsic independent factors that are independently predictive of nonunion in patients with midshaft clavicular fractures after nonoperative treatment. We performed a retrospective study of a series of 804 patients (391 men and 413 women with a median age of 51.3 years) with a radiographically confirmed midshaft clavicle fracture, which was treated nonoperatively. There were 96 patients who underwent nonunion. Putative intrinsic (patient-related) and extrinsic (injured-related) risk factors associated with nonunion were determined with the use of bivariate and multivariate statistical analyses. By bivariate analysis, the risk of nonunion was significantly increased by several intrinsic risk factors including age, sex, and smoking and extrinsic risk factors including displacement of the fracture and the presence of comminution (P<0.05 for all). On multivariate analysis, smoking (OR=4.16, 95% CI: 1.01-14.16), fracture displacement (OR=7.81, 95% CI: 2.27-25.38) and comminution of fracture (OR=3.86, 95% CI: 1.16-13.46) were identified as independent predictive factors. The risk factors for nonunion after nonoperative treatment of midshaft clavicle fractures are multifactorial. Smoking, fracture displacement and comminution of fracture are independent predictors for an individual likelihood of nonunion. Further studies are still required to evaluate these factors in the future. Level III, case-control study. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  13. Sandwich allografts for long-bone nonunions in patients with osteogenesis imperfecta: a retrospective study.

    Science.gov (United States)

    Puvanesarajah, Varun; Shapiro, Jay R; Sponseller, Paul D

    2015-02-18

    Patients with osteogenesis imperfecta often develop nonunions, as internal fixation has limited applicability in this condition. We report the outcomes of a modified "sandwich technique" in the treatment of long-bone nonunions in patients with osteogenesis imperfecta; this technique brings circumferential stabilization and normal collagen to the nonunion site. From May 2003 through February 2012, twelve patients (eight females, four males; median age, 39.0 years; range, eleven to seventy-eight years) who had osteogenesis imperfecta (Sillence type I [three], type III [eight], and type IV [one]) and a combined total of thirteen nonunions (two humeral, two radial, three femoral, four tibial, and two ulnar; median duration, 15.0 months; range, six to 204 months) were treated at our institution with compressed sandwich allograft cortical struts. The struts were fashioned to be wide enough to allow for increased osteoconductive surface area and to approximate a hemicylindrical shape. Treatment history and demographics data were acquired through retrospective chart review. Follow-up radiographs were analyzed by two attending orthopaedic surgeons to determine radiographic findings. The median follow-up time was 4.6 years (range, 2.1 to 10.3 years). All thirteen nonunions, including one requiring a second graft procedure, healed with abundant, smooth allograft incorporation, resulting in an initial healing rate of 92% because of a refracture in one patient. This patient's nonunion ultimately healed with additional allograft struts and a new intramedullary rod. One patient required removal of prominent screws. The final follow-up examinations revealed no pain or refracture at the original nonunion site. All patients regained their prefracture level of function. Sandwich allograft struts constitute a durable, safe method for the stabilization and healing of persistent long-bone nonunions in patients with osteogenesis imperfecta. All patients showed incorporation of the

  14. Bone Scan in Detection of Biological Activity in Nonhypertrophic Fracture Nonunion

    OpenAIRE

    Gandhi, Sunny J.; Rabadiya, Bhavdeep

    2017-01-01

    Biological activity of the fracture site is very important factor in treatment planning of fracture nonunion. If no biological activity is detected, then an autologous bone graft can be supplemented or osteogenic supplementations, such as bone morphogenetic protein is given. If biological activity is present, then secure fixation is sufficient to achieve bony union. Biological activity of nonunions is usually assessed by conventional radiographs. The presence of callus formation is usually as...

  15. South Pole rockets, (1)

    International Nuclear Information System (INIS)

    Kimura, Iwane

    1977-01-01

    Wave-particle interaction was observed, using three rockets, S-210 JA-20, -21 and S-310 JA-2, launched from the South Pole into aurora. Electron density and temperature were measured with these rockets. Simultaneous observations of waves were also made from a satellite (ISIS-II) and at two ground bases (Showa base and Mizuho base). Observed data are presented in this paper. These include electron density and temperature in relation to altitude; variation of electron (60 - 80 keV) count rate with altitude; VLF spectra measured by the PWL of S-210 JA-20 and -21 rockets and the corresponding VLF spectra at the ground bases; low-energy (<10 keV) electron flux measured by S-310 JA-2 rocket; and VLF spectrum measured with S-310 JA-2 rocket. Scheduled measurements for the next project are also briefly described. (Aoki, K.)

  16. Sliding-screw plate fixation of proximal femoral fractures: Radiographic assessment

    Energy Technology Data Exchange (ETDEWEB)

    Sartoris, D.J.; Resnick, D.; Kerr, R.; Goergen, T.

    1985-07-01

    The sliding compression screw-sideplate combination is currently the most widely employed device for internal fixation of stable and unstable intertrochanteric fractures of the femur. The normal and abnormal radiographic appearances of this device in the immediate post-operative period are discussed. Potential long-term complications including mal- or non-union, intra-articular penetration, metal failure, rotation of the proximal fracture fragment, disengagement, trochanteric bursitis, leg length discrepancy, delayed cervical stress fracture, and ischemic necrosis are reviewed.

  17. Sliding-screw plate fixation of proximal femoral fractures: Radiographic assessment

    International Nuclear Information System (INIS)

    Sartoris, D.J.; Resnick, D.; California Univ., San Diego, La Jolla; Kerr, R.; Goergen, T.

    1985-01-01

    The sliding compression screw-sideplate combination is currently the most widely employed device for internal fixation of stable and unstable intertrochanteric fractures of the femur. The normal and abnormal radiogrpahic appearances of this device in the immediate post-operative period are discussed. Potential long-term complications including mal- or non-union, intra-articular penetration, metal failure, rotation of the proximal fracture fragment, disengagement, trochanteric bursitis, leg length discrepancy, delayed cervical stress fracture, and ischemic necrosis are reviewed. (orig.)

  18. Ilizarov′s method for treatment of nonunion of diaphyseal fractures of the humerus

    Directory of Open Access Journals (Sweden)

    Kiran Manish

    2010-01-01

    Full Text Available Background: Nonunion in diaphyseal fractures of the humerus can be treated by various modalities like plating and bone grafting, exchange nailing, fibular strut grafting and Ilizarov′s method of ring fixation. To achieve union in infected nonunion in which multiple surgeries have already been done is further challenging. We conducted a prospective study wherein the outcome of the treatment of nonunion of diaphyseal fractures of the humerus by Ilizarov′s method was analyzed. Materials and Methods: Nineteen patients with diaphyseal nonunion of the humerus were treated by Ilizarov′s external fixator. These included nonunion after plating (n=11, intramedullary nailing (n=1 or conservative methods (n=7. In post-surgical infected nonunion (n=6, the implants were removed, debridement done, bone fragments were docked followed by application of ring fixator and compression. In aseptic nonunion (n=13, distraction for three weeks followed by compression was the protocol. Early shoulder and elbow physiotherapy was instituted. The apparatus was removed after clinical and radiological union and the results were assessed for bone healing and functional status. Results: Fracture union was achieved in all the 19 cases. Pin site infection was seen in 2 cases (10.52%. The bone healing results were excellent in eighteen cases (94.73% and good in one case (5.26%.The functional results were found to be excellent in fourteen cases (73.68%, good in four (21.05% and fair in one case (5.26%. Conclusion: Ilizarov′s method is an excellent option for treatment of septic and aseptic non union of diaphyseal fractures of the humerus as it addresses all the problems associated with non union of the humerus like infection, deformity and joint stiffness.

  19. For early diagnosis of the fracture healing, nonunion and avascular necorsis

    International Nuclear Information System (INIS)

    Kim, Y. C.; Lee, S. H.; Lee, Y. C.; Whang, I. S.; Kim, H. S.

    1981-01-01

    Complications of non-union and avascular necrosis during fracture healing process are the most important problems. Early detection of the evidence of non-union and avascular necrosis and follow-up study of fracture healing process will reduce complications and sequellae in fracture patients. Femoral neck and tibial shaft are the most important fracture sites where non-union and/or avascular necorsis are frequently developed. Osteomedullography was performed in 30 cases of fracture, 21 femoral neck, 8 tibial shafts and 1 talar neck, in the Department of Radiology of national Medical Center during the period form August 1977 to March 1981. The following results were obtained: 1. 16 patients of femoral neck fracture were performed osteomedullography one. Non-union showing no crossing vein through the fracture site was noted in 12 cases from 16 patients. 4 cases from the 12 patients of non-union showed decreased viability but 2 case revealed good viability of the femoral head. 1 case from 4 case of good union of fracture showed no evidence of viability of the femoral head. 2. More than twice of osteomedullography were performed in 5 cases of femoral neck fracture, and crossing vein was not appeared in 4 cases at 3 weeks after fracture. 3 cases showed crossing veins at 6 weeks, and 1 case revealed evidence of avascular necrosis of the femoral head at 9 weeks. 3. In 8 cases of tibial shaft fracture, 4 cases were non-union. Another 4 cases revealed intraosseous veins crossing in fracture site or additional Kaski's osteomedullographic signs, indicating bony union. 4. One talar neck fracture showed bony union with decreased viability of the bony on 12 months after fracture. 5. Osteomedullography is considered as very important study for the early diagnosis of the fracture healing, non-union and avascular necrosis

  20. For early diagnosis of the fracture healing, nonunion and avascular necorsis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y C; Lee, S H; Lee, Y C; Whang, I S; Kim, H S [National Medical Center, Seoul (Korea, Republic of)

    1981-09-15

    Complications of non-union and avascular necrosis during fracture healing process are the most important problems. Early detection of the evidence of non-union and avascular necrosis and follow-up study of fracture healing process will reduce complications and sequellae in fracture patients. Femoral neck and tibial shaft are the most important fracture sites where non-union and/or avascular necorsis are frequently developed. Osteomedullography was performed in 30 cases of fracture, 21 femoral neck, 8 tibial shafts and 1 talar neck, in the Department of Radiology of national Medical Center during the period form August 1977 to March 1981. The following results were obtained: 1. 16 patients of femoral neck fracture were performed osteomedullography one. Non-union showing no crossing vein through the fracture site was noted in 12 cases from 16 patients. 4 cases from the 12 patients of non-union showed decreased viability but 2 case revealed good viability of the femoral head. 1 case from 4 case of good union of fracture showed no evidence of viability of the femoral head. 2. More than twice of osteomedullography were performed in 5 cases of femoral neck fracture, and crossing vein was not appeared in 4 cases at 3 weeks after fracture. 3 cases showed crossing veins at 6 weeks, and 1 case revealed evidence of avascular necrosis of the femoral head at 9 weeks. 3. In 8 cases of tibial shaft fracture, 4 cases were non-union. Another 4 cases revealed intraosseous veins crossing in fracture site or additional Kaski's osteomedullographic signs, indicating bony union. 4. One talar neck fracture showed bony union with decreased viability of the bony on 12 months after fracture. 5. Osteomedullography is considered as very important study for the early diagnosis of the fracture healing, non-union and avascular necrosis.

  1. Osteomedullography: for early diagnosis of the fracture healing, nonunion and avascular necrosis

    International Nuclear Information System (INIS)

    Kim, Y. C.; Lee, S. H.; Lee, Y. C.; Whang, I. S.; Kim, H. S.

    1981-01-01

    Complications of non-union and avascular necrosis during fracture healing process are the most important problem. Early detection of the evidence of non-union and avascular necrosis and follow-up study of fracture healing process will reduce complications and sequellae in fracture patients. Femoral neck and tibial shaft are the most important fracture sites where non-union and/or avascular necrosis are frequently developed. Osteomedullography was performed in 30 cases of fracture, 21 femoral neck, 8 tibial shafts and 1 talar neck, in the Department of Radiology of National Medical Center during the period from August 1977 to March 1981. The following results were obtained: 1. 16 patients of femoral neck fracture were performed osteomedullography once. Non-union showing no crossing vein through the fracture site was noted in 12 cases from 16 patients. 4 cases from the 12 patients of non-union showed decreased viability but 2 case revealed good viability of the femoral head. 1 case from 4 cases of good union of fracture showed no evidence of viability of the femoral head. 2. More than twice of osteomedullography were performed in 5 cases of femoral neck fracture, and crossing vein was not appeared in 4 cases at 3 weeks after fracture. 3 cases showed crossing veins at 6 weeks, and 1 case revealed evidence of avascular necrosis of the femoral head at 9 weeks. 3. In 8 cases of tibial shaft fracture, 4 cases were non-union. Another 4 cases revealed intraosseous veins crossing in fracture site or additional Kaski's osteomedullographic signs, indicating bony union. 4. One talar neck fracture showed bony union with decreased viability of the body on 12 month after fracture. 5. Osteomedullography is considered as very important study for the early diagnosis of the fracture healing, non-union and avascular necrosis

  2. Osteomedullography: for early diagnosis of the fracture healing, nonunion and avascular necrosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y C; Lee, S H; Lee, Y C; Whang, I S; Kim, H S [National Medical Center, Seoul (Korea, Republic of)

    1981-12-15

    Complications of non-union and avascular necrosis during fracture healing process are the most important problem. Early detection of the evidence of non-union and avascular necrosis and follow-up study of fracture healing process will reduce complications and sequellae in fracture patients. Femoral neck and tibial shaft are the most important fracture sites where non-union and/or avascular necrosis are frequently developed. Osteomedullography was performed in 30 cases of fracture, 21 femoral neck, 8 tibial shafts and 1 talar neck, in the Department of Radiology of National Medical Center during the period from August 1977 to March 1981. The following results were obtained: 1. 16 patients of femoral neck fracture were performed osteomedullography once. Non-union showing no crossing vein through the fracture site was noted in 12 cases from 16 patients. 4 cases from the 12 patients of non-union showed decreased viability but 2 case revealed good viability of the femoral head. 1 case from 4 cases of good union of fracture showed no evidence of viability of the femoral head. 2. More than twice of osteomedullography were performed in 5 cases of femoral neck fracture, and crossing vein was not appeared in 4 cases at 3 weeks after fracture. 3 cases showed crossing veins at 6 weeks, and 1 case revealed evidence of avascular necrosis of the femoral head at 9 weeks. 3. In 8 cases of tibial shaft fracture, 4 cases were non-union. Another 4 cases revealed intraosseous veins crossing in fracture site or additional Kaski's osteomedullographic signs, indicating bony union. 4. One talar neck fracture showed bony union with decreased viability of the body on 12 month after fracture. 5. Osteomedullography is considered as very important study for the early diagnosis of the fracture healing, non-union and avascular necrosis.

  3. The South Pole Telescope

    Energy Technology Data Exchange (ETDEWEB)

    Ruhl, J.E.; Ade, P.A.R.; Carlstrom, J.E.; Cho, H.M.; Crawford,T.; Dobbs, M.; Greer, C.H.; Halverson, N.W.; Holzapfel, W.L.; Lanting,T.M.; Lee, A.T.; Leitch, E.M.; Leong, J.; Lu, W.; Lueker, M.; Mehl, J.; Meyer, S.S.; Mohr, J.J.; Padin, S.; Plagge, T.; Pryke, C.; Runyan, M.C.; Schwan, D.; Sharp, M.K.; Spieler, H.; Staniszewski, Z.; Stark, A.A.

    2004-11-04

    A new 10 meter diameter telescope is being constructed for deployment at the NSF South Pole research station. The telescope is designed for conducting large-area millimeter and sub-millimeter wave surveys of faint, low contrast emission, as required to map primary and secondary anisotropies in the cosmic microwave background. To achieve the required sensitivity and resolution, the telescope design employs an off-axis primary with a 10 m diameter clear aperture. The full aperture and the associated optics will have a combined surface accuracy of better than 20 microns rms to allow precision operation in the submillimeter atmospheric windows. The telescope will be surrounded with a large reflecting ground screen to reduce sensitivity to thermal emission from the ground and local interference. The optics of the telescope will support a square degree field of view at 2mm wavelength and will feed a new 1000-element micro-lithographed planar bolometric array with superconducting transition-edge sensors and frequency-multiplexed readouts. The first key project will be to conduct a survey over 4000 degrees for galaxy clusters using the Sunyaev-Zeldovich Effect. This survey should find many thousands of clusters with a mass selection criteria that is remarkably uniform with redshift. Armed with redshifts obtained from optical and infrared follow-up observations, it is expected that the survey will enable significant constraints to be placed on the equation of state of the dark energy.

  4. Prospective clinical trial of surgical intervention for painful rib fracture nonunion.

    Science.gov (United States)

    Fabricant, Loic; Ham, Bruce; Mullins, Richard; Mayberry, John

    2014-06-01

    We performed a prospective clinical trial of resection with or without plate fixation for symptomatic rib fracture nonunion three or more months postinjury with 6-month postoperative followup. The McGill Pain Questionnaire (MPQ) and RAND 36 Health Survey were administered and activity level (sedentary, ambulatory, moderately active, vigorous), functional status (disabled, nonphysical labor, physical labor), and work status (employed, unemployed, retired, student) were queried pre- and postoperatively. Twenty-four patients 4 to 197 months (median, 16 months) postinjury underwent surgical intervention for one to four rib fracture nonunions (median, two nonunions). Evidence of intercostal nerve entrapment was present in nine patients (38%). MPQ Present Pain Intensity and Pain Rating Index and RAND 36 Physical Functioning, Role Physical, Social Functioning, Role Social, Bodily Pain, Vitality, Mental Health, and General Health were significantly improved at six months compared with study entry (P rib fracture nonunion may improve chronic pain and disability but without change in functional or work status. Resection of adjacent nonunions with significant gaps may lead to chest wall hernia.

  5. Evaluation of the pole figure

    International Nuclear Information System (INIS)

    Cabrera B, E.; Macias B, L.R.

    1984-01-01

    In the present work it's shown the possibility of obtaining a pole-figure from the data generated in a conventional X-ray equipment, with a commercial goniometer and no electronic device to process the data. The way to plot the pole-figure on-line is by means of measuring the diffractogram and plot manually the stereographic projections. The atainable precision is very low in such a cumbersome process. In this paper we substitute such method by storing the data in a punched tape from a conventional teletype. The data is processed in a computer and the pole-figure is recorded by a plotter attached to the computer. (author)

  6. Regge poles and alpha scattering

    International Nuclear Information System (INIS)

    Ceuleneer, R.

    1974-01-01

    The direct Regge pole model as a means of describing resonances in elastic particle scattering has been used for the analysis of the so-called ''anormalous large angle scattering'' of alpha particles by spinless nuclei. (Z.M.)

  7. A novel treatment approach to infected nonunion of long bones without systemic antibiotics.

    Science.gov (United States)

    Masrouha, Karim Z; Raad, Michael E; Saghieh, Said S

    2018-04-01

    Infected nonunion of long bones may require intravenous antibiotics over a lengthy period which may result in a high rate of complications. This study aims to assess the efficacy of local antibiotics used as a replacement to prolonged intravenous therapy. Thirteen patients with infected nonunion of long bones who failed at least one previous surgery were included. The infection was treated through extensive debridement, application of antibiotic-impregnated calcium sulphate pellets and the bone stabilized with external fixation. These patients were monitored for union and infection by clinical signs, laboratory values, and radiographs over a period of 24 months. The results support an eradication of infection and union in all patients with no antibiotic-associated complications. Local antibiotic delivery using calcium sulphate pellets provides an effective method for treatment of nonunion in long bones and is free of the complications from the intravenous route.

  8. Management of complex femoral nonunion with monorail external fixator: A prospective study.

    Science.gov (United States)

    Agrawal, Hemendra Kumar; Garg, Mohit; Singh, Balvinder; Jaiman, Ashish; Khatkar, Vipin; Khare, Shailender; Batra, Sumit; Sharma, Vinod Kumar

    2016-01-01

    To evaluate 30 patients who underwent distraction osteogenesis with monorail external fixator for complex femoral nonunion. Complex femoral nonunion includes infective non-union, gap nonunion, and limb-length discrepancy secondary to traumatic bone loss, which needs specialized treatment to ensure the functional integrity of femoral bone. 30 patients, including 28 male and 2 female (aged 22-62 years) patients, underwent surgical debridement followed by bone transport with monorail fixator. The lengthening index, radiographic consolidation index, functional status, bone healing, and various problems, obstacles, and complications encountered during the treatment were assessed. Patients underwent a mean of 2.2 (range 1-4) surgeries before presentation. The mean bone defect after surgical debridement was 5.83 cm (range 2-16 cm). The mean treatment duration was 204.7 days (range 113-543 days). The mean lengthening index was 13.06 days/cm with range from 12 to 16 days/cm. Mean maturation index was 23.51 days/cm with range from 17 to 45.5 days/cm. In our study, bone result was excellent in 17, good in 9, fair in 3, and poor in 1 patient. In our study functional outcome is excellent in 9 [30%], good in 14 [46.67%], fair in 5, and poor in 2 patients. In our study, we encountered 34 problems, 17 obstacles, and 8 complications. We concluded that monorail external fixator is an effective treatment option for complex nonunion femoral shaft fracture and its functional outcome is comparable with any other treatment options. Lack of complications and its effectiveness makes monorail external fixator the treatment of choice for complex nonunion femoral shaft.

  9. Tension band plating of a nonunion anterior tibial stress fracture in an athlete.

    Science.gov (United States)

    Merriman, Jarrad A; Villacis, Diego; Kephart, Curtis J; Rick Hatch, George F

    2013-07-01

    The authors present a rare technique of tension band plating of the anterior tibia in the setting of a nonunion stress fracture. Surgical management with an intramedullary nail is a viable and proven option for treating such injuries. However, in treating elite athletes, legitimate concerns exist regarding the surgical disruption of the extensor mechanism and the risk of anterior knee pain associated with intramedullary nail use. The described surgical technique demonstrates the use of tension band plating as an effective treatment of delayed union and nonunion anterior tibial stress fractures in athletes without the potential risks of intramedullary nail insertion. Copyright 2013, SLACK Incorporated.

  10. Acute peg in hole docking in the management of infected non-union of long bones

    OpenAIRE

    Dhar, Shabir Ahmed; Mir, Mohammed Ramzan; Ahmed, Molvi Sajjad; Afzal, Suhail; Butt, Mohammed Farooq; Badoo, A. R.; Dar, Irshad Tabasum; Hussain, Anwar

    2007-01-01

    The Ilizarov method has been studied extensively in the management of non-union of long bones. In most cases this involves filling of defects present primarily or after débridement by bone transport. Acute docking over gaps longer than 2 cm has not been adequately studied, however. The purpose of this paper is to report the efficacy of acute peg in hole docking as a bone graft-sparing modality in the management of infected non-union of long bones.

  11. Acute peg in hole docking in the management of infected non-union of long bones.

    Science.gov (United States)

    Dhar, Shabir Ahmed; Mir, Mohammed Ramzan; Ahmed, Molvi Sajjad; Afzal, Suhail; Butt, Mohammed Farooq; Badoo, A R; Dar, Irshad Tabasum; Hussain, Anwar

    2008-08-01

    The Ilizarov method has been studied extensively in the management of non-union of long bones. In most cases this involves filling of defects present primarily or after débridement by bone transport. Acute docking over gaps longer than 2 cm has not been adequately studied, however. The purpose of this paper is to report the efficacy of acute peg in hole docking as a bone graft-sparing modality in the management of infected non-union of long bones.

  12. Omentalisation as adjunctive treatment of an infected femoral nonunion fracture: a case report

    Directory of Open Access Journals (Sweden)

    McAlinden A

    2009-10-01

    Full Text Available Abstract A three-year-old male working border collie with an infected femoral nonunion fracture was managed in a two-stage procedure involving debridement and omentalisation, followed by stabilisation with a bone plate and an autogenous cancellous bone graft. Osseous union was documented radiographically 16 weeks after surgery. Telephone follow-up one year later revealed the dog had returned to full working function without evidence of lameness. To the authors' knowledge, this is the first clinical case described in the veterinary literature using omentalisation as an adjunct to the management of an infected, biologically inactive nonunion fracture.

  13. Intramedullary nailing for the treatment of aseptic femoral shaft non-unions after plating failure: effectiveness and timing.

    Science.gov (United States)

    Megas, Panagiotis; Syggelos, Spyros A; Kontakis, Georgios; Giannakopoulos, Andreas; Skouteris, Georgios; Lambiris, Elias; Panagiotopoulos, Elias

    2009-07-01

    This retrospective, multicentre study aimed to evaluate reamed intramedullary nailing (IMN) for the treatment of 30 cases of aseptic femoral shaft non-union after plating failure. Following nailing, 29 non-unions had healed by a mean 7.93 months. In one case a hypertrophic non-union required renailing after 8 months, using a nail of greater diameter, and united within five further months. Healing times were not related to whether the fracture was open or closed, the type non-union or the type of fracture. The delay from the initial plating to intramedullary nailing had a statistically significant effect on healing time and final outcome. This treatment is cost effective and should be implemented as soon as the non-union is diagnosed.

  14. Non-union of the trapezium: rare consequence of a rare injury

    Science.gov (United States)

    Samson, Deepak; Jones, Matthew; Mahon, Andrew

    2018-01-01

    Abstract Fractures of the trapezium are rare and easily missed. As these injuries are often imperceptible on plain radiographs, diagnosis in the ED setting is challenging. We report a case of an isolated fracture of the trapezium which was picked up as a non-union 5 months after the injury following persistence of symptoms. PMID:29765589

  15. Does Computed Tomography Change our Observation and Management of Fracture Non-Unions?

    Directory of Open Access Journals (Sweden)

    Ydo V. Kleinlugtenbelt

    2016-10-01

    In this study, the interobserver reliability of MDCT scan is not greater than conventional radiographs for determining non-union. However, a MDCT scan did lead to a more invasive approach in equivocal cases. Therefore a MDCT is only recommended for making treatment strategies in those cases.

  16. Multiple Rib Nonunion: Open Reduction and Internal Fixation and Iliac Crest Bone Graft Aspirate.

    Science.gov (United States)

    Kaplan, Daniel J; Begly, John; Tejwani, Nirmal

    2017-08-01

    Rib fractures are a common chest injury that can typically be treated nonoperatively. However, a percentage of these will go on to nonunion, either because of unique characteristics of the fracture itself or because of a variety of poor healing factors of the host. If a patient has continued symptomology beyond 3 months, surgeons may consider operative management. Although isolated resection of fibrous scar tissue from the nonunion site may be sufficient in some cases, it may also be necessary to provide additional structural integrity to the rib depending on the extent of the fracture pattern and resection. This goal can be achieved operatively with rib plating and bone grafting to promote healing. This video demonstrates the use of plating in the treatment of rib nonunion. It begins with relevant background information on rib fractures and nonunions, then details the approach, open reduction and internal fixation of 3 ribs using plates and bone graft aspirate. Pearls and pitfalls are included during the surgical technique aspect of the video to both help guide surgeons new to the procedure and provide potentially advantageous technical details to more experienced surgeons.

  17. Implant failure caused by non-union of bisphosphonate-associated subtrochanteric femur fracture.

    LENUS (Irish Health Repository)

    O'Neill, Barry James

    2014-04-03

    Bisphosphonate use has been identified as a contributory factor in atypical subtrochanteric fracture of the femur. These fractures are commonly treated with an intramedullary device. We present a case of implant failure of an intrameduallary device caused by non-union of an atypical subtrochanteric fracture.

  18. Nonunion of the femoral neck: possibilities and limitations of the various treatment modalities

    NARCIS (Netherlands)

    Raaymakers, Ernst L. F. B.; Marti, René K.

    2008-01-01

    Nowadays in cases of nonunions of the femoral neck, the surgeon is tempted to perform prosthetic replacement of the hip, more so if there is also evidence of avascular necrosis of the head of femur. This provides rapid pain relief and allows early mobilization. However, long-term results of hip

  19. Dynamic contrast-enhanced magnetic resonance imaging can assess vascularity within fracture non-unions and predicts good outcome

    Energy Technology Data Exchange (ETDEWEB)

    Schoierer, Oliver; Bender, Daniel; Schmidmaier, Gerhard [University Hospital Heidelberg, Heidelberg Trauma Research Group, Department of Orthopaedic and Trauma Surgery, Heidelberg (Germany); Bloess, Konstantin; Kauczor, Hans-Ulrich; Weber, Marc-Andre [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Burkholder, Iris [University of Applied Sciences of the Saarland, Department of Nursing and Health, Saarbruecken (Germany)

    2014-02-15

    To prospectively evaluate whether dynamic contrast-enhanced (DCE) MRI can assess vascularity within non-unions and predicts clinical outcome in combination with the clinical Non-Union Scoring System (NUSS). Fifty-eight patients with non-unions of extremities on CT underwent 3-T DCE MRI. Signal intensity curves obtained from a region-of-interest analysis were subdivided into those with more intense contrast agent uptake within the non-union than in adjacent muscle (vascularised non-union) and those with similar or less contrast uptake. The pharmacokinetic parameters of the Tofts model K{sub trans}, K{sub ep}, iAUC and V{sub e} were correlated with union at CT 1 year later (n = 49). Despite inserted osteosynthetic material, DCE parameters could be evaluated in 57 fractures. The sensitivity/specificity of vascularised non-unions as an indicator of good outcome was 83.9 %/50.0 % compared to 96.8 %/33.3 % using NUSS (n = 49). Logistic regression revealed a significant impact of NUSS on outcome (P = 0.04, odds ratio = 0.93). At first examination, median iAUC (initial area under the enhancement curve) for the ratio non-union/muscle was 10.28 in patients with good outcome compared with 3.77 in non-responders (P = 0.023). K{sub trans}, K{sub ep} and V{sub e} within the non-union were not significantly different initially (n = 57) or 1 year later (n = 19). DCE MRI can assess vascularity in fracture non-unions. A vascularised non-union correlates with good outcome. (orig.)

  20. Dynamic contrast-enhanced magnetic resonance imaging can assess vascularity within fracture non-unions and predicts good outcome

    International Nuclear Information System (INIS)

    Schoierer, Oliver; Bender, Daniel; Schmidmaier, Gerhard; Bloess, Konstantin; Kauczor, Hans-Ulrich; Weber, Marc-Andre; Burkholder, Iris

    2014-01-01

    To prospectively evaluate whether dynamic contrast-enhanced (DCE) MRI can assess vascularity within non-unions and predicts clinical outcome in combination with the clinical Non-Union Scoring System (NUSS). Fifty-eight patients with non-unions of extremities on CT underwent 3-T DCE MRI. Signal intensity curves obtained from a region-of-interest analysis were subdivided into those with more intense contrast agent uptake within the non-union than in adjacent muscle (vascularised non-union) and those with similar or less contrast uptake. The pharmacokinetic parameters of the Tofts model K trans , K ep , iAUC and V e were correlated with union at CT 1 year later (n = 49). Despite inserted osteosynthetic material, DCE parameters could be evaluated in 57 fractures. The sensitivity/specificity of vascularised non-unions as an indicator of good outcome was 83.9 %/50.0 % compared to 96.8 %/33.3 % using NUSS (n = 49). Logistic regression revealed a significant impact of NUSS on outcome (P = 0.04, odds ratio = 0.93). At first examination, median iAUC (initial area under the enhancement curve) for the ratio non-union/muscle was 10.28 in patients with good outcome compared with 3.77 in non-responders (P = 0.023). K trans , K ep and V e within the non-union were not significantly different initially (n = 57) or 1 year later (n = 19). DCE MRI can assess vascularity in fracture non-unions. A vascularised non-union correlates with good outcome. (orig.)

  1. Glass Waveguides for Periodic Poling

    DEFF Research Database (Denmark)

    Fage-Pedersen, Jacob; Jacobsen, Rune Shim; Kristensen, Martin

    2005-01-01

    Planar silica-based waveguide devices have been developed for second-harmonic generation by poling with periodic electrodes. We show that detrimental charge transport can occur along interfaces, but with proper choice of fabrication, high-quality devices are obtained....

  2. Poling of UV-written Waveguides

    DEFF Research Database (Denmark)

    Arentoft, Jesper; Kristensen, Martin; Hübner, Jörg

    1999-01-01

    We report poling of UV-written silica waveguides. Thermal poling induces an electro-optic coefficient of 0.05 pm/V. We also demonstrate simultaneous UV-writing and UV-poling. No measurable decay in the induced electro-optic effect was detected after nine months......We report poling of UV-written silica waveguides. Thermal poling induces an electro-optic coefficient of 0.05 pm/V. We also demonstrate simultaneous UV-writing and UV-poling. No measurable decay in the induced electro-optic effect was detected after nine months...

  3. Nonunion of the external maxillary distraction in cleft lip and palate: analysis of possible reasons.

    Science.gov (United States)

    He, Dongmei; Genecov, David G; Barcelo, Raul

    2010-10-01

    Distraction osteogenesis (DO) is an effective way to treat severe maxillary deficiency in patients with cleft lip and palate. It has been reported to have long-term stability and low relapse rate compared with conventional maxillary osteotomy in large maxillary movement. However, complications such as nonunion are seldom reported. While developing our external distraction techniques, we had 4 nonunion cleft lip and palate (CLP) patients. The aim of this study is to analyze the possible reasons for these conditions by comparing them to patients successfully treated at 1 craniofacial institute. Fifty-six patients with CLP deformities treated with external maxillary distraction from 2000 to 2006 in 1 craniofacial center were reviewed. Among them, 17 had full records and follow-up time of more than 1 year. They had rigid external halo distraction with dental splint after a high Le Fort I osteotomy. Distraction was started at 5 days with a rate of 1 mm per day until the maxilla acquired the planned correction. Consolidation time ranged from 4 weeks to 3 months. Patients' general information, DO protocol, and cephalometric radiograph measurements before DO, immediately after DO, and follow-ups were evaluated. Thirteen of 17 patients successfully completed DO, whereas 4 others developed dental occlusion relapse 2 to 3 months after device removal. Later jaw surgery showed nonunion at the distraction sites. These were our first patients treated with external distraction. Their consolidation time was from 4 to 6 weeks with a mean of 5.2 weeks. After increasing the consolidation time up to 12 weeks, all of the other 13 patients had successful results without nonunion. Their mean consolidation time was 9.8 weeks. The nonunion group had significantly shorter consolidation time, older age, and larger distraction osteogenesis (DO) advancement than the successful group statistically. There was also a greater percentage of bilateral CLP patients in the nonunion group than in the

  4. Biomechanical Strength of Retrograde Fixation in Proximal Third Scaphoid Fractures.

    Science.gov (United States)

    Daly, Charles A; Boden, Allison L; Hutton, William C; Gottschalk, Michael B

    2018-04-01

    Current techniques for fixation of proximal pole scaphoid fractures utilize antegrade fixation via a dorsal approach endangering the delicate vascular supply of the dorsal scaphoid. Volar and dorsal approaches demonstrate equivalent clinical outcomes in scaphoid wrist fractures, but no study has evaluated the biomechanical strength for fractures of the proximal pole. This study compares biomechanical strength of antegrade and retrograde fixation for fractures of the proximal pole of the scaphoid. A simulated proximal pole scaphoid fracture was produced in 22 matched cadaveric scaphoids, which were then assigned randomly to either antegrade or retrograde fixation with a cannulated headless compression screw. Cyclic loading and load to failure testing were performed and screw length, number of cycles, and maximum load sustained were recorded. There were no significant differences in average screw length (25.5 mm vs 25.6 mm, P = .934), average number of cyclic loading cycles (3738 vs 3847, P = .552), average load to failure (348 N vs 371 N, P = .357), and number of catastrophic failures observed between the antegrade and retrograde fixation groups (3 in each). Practical equivalence between the 2 groups was calculated and the 2 groups were demonstrated to be practically equivalent (upper threshold P = .010). For this model of proximal pole scaphoid wrist fractures, antegrade and retrograde screw configuration have been proven to be equivalent in terms of biomechanical strength. With further clinical study, we hope surgeons will be able to make their decision for fixation technique based on approaches to bone grafting, concern for tenuous blood supply, and surgeon preference without fear of poor biomechanical properties.

  5. Patellar Shape-Memory Fixator for the Treatment of Comminuted Fractures of the Inferior Pole of the Patella

    Science.gov (United States)

    Liu, Xin-Wei; Shang, Hui-Juan; Xu, Shuo-Gui; Wang, Zhi-Wei; Zhang, Chun-Cai; Fu, Qing-Ge

    2011-07-01

    Comminuted and displaced fractures of the inferior pole of the patella are not easy to reduce and it is difficult to fix the fragments soundly enough to allow early movement of the knee. The purpose of this study is to evaluate the clinical effectiveness of the internal fixation technique with Patellar Shape-Memory Fixator (PSMF) in acute comminuted fractures of the inferior pole of the patella. We retrospectively studied 25 patients with comminuted fractures of the inferior pole of the patella who were treated with PSMF and followed up for a mean period of 26 months (14 to 60). All the fractures healed at a mean of 6 weeks (5 to 7). The mean grading at the final follow-up was 29.5 points (27 to 30) using the Bostman score, with no observable restriction of movement. No breakage of the PSMF or infection occurred. No delayed union, nonunion, and infection were seen. This technique preserved the length of the patella, reduced the comminuted fragments of the inferior pole and avoided long-term immobilization of the knee.

  6. INNOVATIVE CLUSTER OR COMPETITIVENESS POLE?

    Directory of Open Access Journals (Sweden)

    Liliana Scutaru

    2015-02-01

    Full Text Available The paper analyzes the situation of clusters in Romania and their areas of activity and innovation in entrepreneurship Romanian state. It is made also a territorial distribution of clusters on the eight regions. The findings lead to the conclusion that there are some clusters that have the vocation to become poles of competitiveness in areas such as renewable energy, automotive, electronics, health, biotechnology, mechatronics or ICT (Information and Communication Technology which represent the resources for future of the Romanian economy. Regarding the degree of innovation of Romanian Small and Medium Enterprises (SMEs, the level is relatively modest, 30.8% of all enterprises being innovative. If we were to answer the question the title suggests, we would say "yes" to both since the innovative cluster as well as the competitiveness pole promotes par excellence, innovation through study, research and stimulation of creativity. And this is more than enough to support economic growth of Romania and maintain the competitiveness worldwide.

  7. Pole counting and resonance classification

    International Nuclear Information System (INIS)

    Morgan, D.

    1992-01-01

    S-wave resonances occurring close to an inelastic threshold can be classified according to the number of nearby poles they possess. One then has a useful possibility of distinguishing dynamical alternatives by objective appeal to data. Making this quantitative entails developing suitable effective range expansions for various realizations of potential scattering. A key application is deciding the make-up of f 0 (976) (S*). (author)

  8. The Critical Size Defect as an Experimental Model for Craniomaxillofacial Nonunions,

    Science.gov (United States)

    1985-01-01

    1976, p. 125. 59. Stanley, R.R. and Rice, D.H.: Osteogenesis From a Free Periosteal Graft in Mandibular Reconstruction. Otolaryngol. Head Neck Surg... embryologically , the calvaria develops from a 17 rane precursor and thus resembles the membranous bones of the face. .nmically, the calvaria consists of...Nonunion in Dogs. Clin. Orthop. 187:260, 1984. 24 49. Paff, G.r.: Anatamy of the Read and Neck . Philadelphia, W.R. Saunders Co., 1973, p. 77. 50

  9. Transfracture abduction osteotomy: A solution for nonunion of femoral neck fractures

    Directory of Open Access Journals (Sweden)

    Jairamchander Pingle

    2014-01-01

    femur with or without bone graft, valgus osteotomy or hip arthroplasty. We conducted a retrospective analysis of cases of nonunion of femoral neck fracture treated by transfracture abduction osteotomy (TFAO. Materials and Methods: Over a period of 35 years (1974-2008, 30 patients with nonunion of femoral neck fractures were treated with TFAO over a period of 35 years (1974-2008, All patients were less than 50 years of age. Absence of clinical and radiological signs of union after four months was considered as nonunion. Patients more than 50 years of age were excluded from the study. Union was assessed at 6 months radiologically. Limb length was measured at six months. The mean duration of femoral neck fracture was 19 months (range 4 months 10 years. Results were analyzed in terms of radiological union at six months. Average followup was five years and six months. Results: Consistent union was noted at the followup after six months in 29 cases. One case was lost to followup after five and one-half months postoperatively. However, the fracture had united in this case at the last followup. Average shortening of the limb at six months was 1.9 cm. Average neck shaft angle was 127° (range 120-145°. Five cases went into AVN but were asymptomatic. Two cases required reoperation due to back out of Moore′s pins. These were reopened and cancellous screws were inserted in the same tracks. Conclusions: Consistent union of nonunion femoral neck fracture was noted at the followup after six months in 29 cases. The major drawback of the procedure is immobilization of the patient in the hip spica for eight weeks.

  10. Contemporary Management of Mandibular Fracture Nonunion-A Retrospective Review and Treatment Algorithm.

    Science.gov (United States)

    Ostrander, Benjamin T; Wang, Howard D; Cusano, Alessandro; Manson, Paul N; Nam, Arthur J; Dorafshar, Amir H

    2018-02-06

    Nonunion is an uncommon complication after mandibular fractures. The purpose of this investigation was to compare outcomes of patients with mandibular fracture nonunion who were treated with a 1- versus 2-stage approach and propose a pragmatic treatment algorithm for surgical management based on preoperative characteristics. The authors conducted a retrospective study consisting of patients who presented to 2 level 1 trauma centers for the management of mandibular fracture nonunion over a 10-year period. The primary predictor variable was 1- versus 2-stage treatment. Outcomes were examined to propose a treatment algorithm. Eighteen patients were included in the study. The sample's mean age was 44.0 ± 19.3 years and most were men (88.9%). Mandibular angle and body accounted for 77.8% of cases. A single-stage approach was used in 13 patients (72.2%). Bone grafts or vascularized bone flaps were required in 13 patients (72.2%). Patients who required 2-stage treatments had intraoral soft tissue defects. Mean length of follow-up was 13.3 ± 20.4 months. All patients achieved bony union, with complications occurring in 5 patients (27.8%). The authors' 10-year experience was used to formulate a treatment algorithm based on bony defect size and soft tissue status, which can be used to inform optimal surgical management. Nonunion of mandibular fractures is an infrequent and complex condition requiring careful and deliberate surgical management. A single-stage approach is appropriate in most cases and does not negatively affect outcomes. Bony defect size and soft tissue status are essential parameters for determining the approach and timing of reconstruction. Copyright © 2018 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Coupled external fixator and skin flap transposition for treatment of exposed and nonunion bone.

    Science.gov (United States)

    Zhao, Yong-gang; Ding, Jing; Wang, Neng

    2011-02-01

    To discuss the effect of coupled external fixator and skin flap transposition on exposed and nonunion bones. The data of 12 cases of infected nonunion and exposed bone following open fracture treated in our hospital during the period of March 1998 to June 2008 were analysed. There were 10 male patients, 2 female patients, whose age were between 19-52 years and averaged 28 years. There were 10 tibial fractures and 2 femoral fractures. The course of diseases lasted for 12-39 months with the mean period of 19 months. All the cases were treated by the coupled external fixator and skin flap transposition. Primary healing were achieved in 10 cases and delayed healing in 2 cases in whom the tibia was exposed due to soft tissue defect and hence local flap transposition was performed. All the 12 cases had bony union within 6-12 months after operation with the average time of 8 months. They were followed up for 1-3 years and all fractures healed up with good function and no infection recurrence. The coupled external fixator and skin flap transposition therapy have shown optimal effects on treating infected, exposed and nonunion bones.

  12. Central bone grafting for nonunion of fractures of the tibia: a retrospective series.

    Science.gov (United States)

    Ryzewicz, M; Morgan, S J; Linford, E; Thwing, J I; de Resende, G V P; Smith, W R

    2009-04-01

    Nonunion of the tibia associated with bone loss, previous infection, obliteration of the intramedullary canal or located in the distal metaphysis poses a challenge to the surgeon and significant morbidity to patients. We retrospectively reviewed the records of 24 patients who were treated by central bone grafting and compared them to those of 20 who were treated with a traditional posterolateral graft. Central bone grafting entails a lateral approach, anterior to the fibula and interosseous membrane which is used to create a central space filled with cancellous iliac crest autograft. Upon consolidation, a tibiofibular synostosis is formed that is strong enough for weight-bearing. This procedure has advantages over other methods of treatment for selected nonunions. Of the 24 patients with central bone grafting, 23 went on to radiographic and clinical union without further intervention. All healed within a mean of 20 weeks (10 to 48). No further bone grafts were required, and few complications were encountered. These results were comparable to those of the 20 patients who underwent posterolateral bone grafting who united at a mean of 31.3 weeks (16 to 60) but one of whom required below-knee amputation for intractable sepsis. Central bone grafting is a safe and effective treatment for difficult nonunions of the tibia.

  13. Analysis of ulnar variance as a risk factor for developing scaphoid nonunion.

    Science.gov (United States)

    Lirola-Palmero, S; Salvà-Coll, G; Terrades-Cladera, F J

    2015-01-01

    Ulnar variance may be a risk factor of developing scaphoid non-union. A review was made of the posteroanterior wrist radiographs of 95 patients who were diagnosed of scaphoid fracture. All fractures with displacement less than 1mm treated conservatively were included. The ulnar variance was measured in all patients. Ulnar variance was measured in standard posteroanterior wrist radiographs of 95 patients. Eighteen patients (19%) developed scaphoid nonunion, with a mean value of ulnar variance of -1.34 (-/+ 0.85) mm (CI -2.25 - 0.41). Seventy seven patients (81%) healed correctly, and the mean value of ulnar variance was -0.04 (-/+ 1.85) mm (CI -0.46 - 0.38). A significant difference was observed in the distribution of ulnar variance (pvariance less than -1mm, and ulnar variance greater than -1mm. It appears that patients with ulnar variance less than -1mm had an OR 4.58 (CI 1.51 to 13.89) with pvariance less than -1mm have a greater risk of developing scaphoid nonunion, OR 4.58 (CI 1.51 to 13.89) with p<.007. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  14. Nonunion of the humerus following intramedullary nailing treated by Ilizarov hybrid fixation.

    Science.gov (United States)

    Raschke, M; Khodadadyan, C; Maitino, P D; Hoffmann, R; Südkamp, N P

    1998-02-01

    A case of a posttraumatic humeral shaft nonunion, after intramedullary stabilization with a Seidel nail, is presented. Severe osteoporosis, an oligotrophic nonunion, subclinical infection, and adhesive capsulitis of the glenohumeral joint were present. Due to the subclinical infection and severe osteoporosis, other major invasive therapeutic options such as intramedullary nailing or compression plating and bone grafting were not applicable. Nonoperative treatment was also not indicated secondary to the pain and disability present. External fixation with the Ilizarov hybrid fixator seemed to offer a minimally invasive treatment modality without the need of additional bone grafting. After fourteen weeks of "callus massage," consisting of closed alternating compression and distraction with an Ilizarov hybrid fixator, osseous consolidation was achieved. Eight months after Ilizarov treatment the patient had returned to work as a mechanic. At the one-year follow-up examination, the patient presented pain free and with near normal shoulder and elbow motion, with stable osseous consolidation of the humerus. In some cases of nonunion of the humerus shaft, when standard treatment options are not recommended, external fixation with an Ilizarov hybrid fixator may offer a salvage procedure with a successful clinical outcome.

  15. Nonvascularized fibular grafting in nonunion of femoral neck fracture: A systematic review

    Directory of Open Access Journals (Sweden)

    Sujit Kumar Tripathy

    2016-01-01

    Full Text Available Nonunion of femoral neck fractures following primary fixation and neglected femoral neck fracture in young adults is a challenging task. Every effort should be directed toward hip joint salvage in these patients. Among different available options of hip salvage, nonvascularized fibular graft (NVFG osteosynthesis is simple, easy to perform, and a successful technique. In this review, the available literature on NVFG in neglected and nonunion femoral neck fractures has been analyzed. After review of 15 articles on NVFG, the average nonunion rate was estimated to be 7.86% (range 0-31%. Six articles that evaluated the preoperative and postoperative osteonecrosis reported improvement in 50% patients. The clinical and/or functional outcome was good to excellent in 56-96% patients following fibular osteosynthesis. Few complications such as coxa vara deformity, limb shortening, and intraarticular penetration of the graft or hardware have been reported. However, there are minimal donor site morbidities such as mild ankle pain, transient loss of toe flexors and extensors and transient lateral popliteal nerve palsy.

  16. Modeling Staphylococcus epidermidis-Induced Non-Unions: Subclinical and Clinical Evidence in Rats.

    Directory of Open Access Journals (Sweden)

    Arianna Barbara Lovati

    Full Text Available S. epidermidis is one of the leading causes of orthopaedic infections associated with biofilm formation on implant devices. Open fractures are at risk of S. epidermidis transcutaneous contamination leading to higher non-union development compared to closed fractures. Although the role of infection in delaying fracture healing is well recognized, no in vivo models investigated the impact of subclinical low-grade infections on bone repair and non-union. We hypothesized that the non-union rate is directly related to the load of this commonly retrieved pathogen and that a low-grade contamination delays the fracture healing without clinically detectable infection. Rat femurs were osteotomized and stabilized with plates. Fractures were infected with a characterized clinical-derived methicillin-resistant S. epidermidis (10(3, 10(5, 10(8 colony forming units and compared to uninfected controls. After 56 days, bone healing and osteomyelitis were clinically assessed and further evaluated by micro-CT, microbiological and histological analyses. The biofilm formation was visualized by scanning electron microscopy. The control group showed no signs of infection and a complete bone healing. The 10(3 group displayed variable response to infection with a 67% of altered bone healing and positive bacterial cultures, despite no clinical signs of infection present. The 10(5 and 10(8 groups showed severe signs of osteomyelitis and a non-union rate of 83-100%, respectively. The cortical bone reaction related to the periosteal elevation in the control group and the metal scattering detected by micro-CT represented limitations of this study. Our model showed that an intra-operative low-grade S. epidermidis contamination might prevent the bone healing, even in the absence of infectious signs. Our findings also pointed out a dose-dependent effect between the S. epidermidis inoculum and non-union rate. This pilot study identifies a relevant preclinical model to assess the

  17. Method and apparatus for assembling a permanent magnet pole assembly

    Science.gov (United States)

    Carl, Jr., Ralph James; Bagepalli, Bharat Sampathkumaran [Niskayuna, NY; Jansen, Patrick Lee [Scotia, NY; Dawson, Richard Nils [Voorheesville, NY; Qu, Ronghai [Clifton Park, NY; Avanesov, Mikhail Avramovich [Moscow, RU

    2009-08-11

    A pole assembly for a rotor, the pole assembly includes a permanent magnet pole including at least one permanent magnet block, a plurality of laminations including a pole cap mechanically coupled to the pole, and a plurality of laminations including a base plate mechanically coupled to the pole.

  18. Proximity credentials: A survey

    International Nuclear Information System (INIS)

    Wright, L.J.

    1987-04-01

    Credentials as a means of identifying individuals have traditionally been a photo badge and more recently, the coded credential. Another type of badge, the proximity credential, is making inroads in the personnel identification field. This badge can be read from a distance instead of being veiewed by a guard or inserted into a reading device. This report reviews proximity credentials, identifies the companies marketing or developing proximity credentials, and describes their respective credentials. 3 tabs

  19. Proximal Probes Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Proximal Probes Facility consists of laboratories for microscopy, spectroscopy, and probing of nanostructured materials and their functional properties. At the...

  20. [18F]FDG PET accurately differentiates infected and non-infected non-unions after fracture fixation

    International Nuclear Information System (INIS)

    Wenter, Vera; Albert, Nathalie L.; Brendel, Matthias; Fendler, Wolfgang P.; Bartenstein, Peter; Cyran, Clemens C.; Friederichs, Jan; Mueller, Jan-Philipp; Militz, Matthias; Hungerer, Sven; Hacker, Marcus

    2017-01-01

    Complete fracture healing is crucial for good patient outcomes. A major complication in the treatment of fractures is non-union. The pathogenesis of non-unions is not always clear, although implant-associated infections play a significant role, especially after surgical treatment of open fractures. We aimed to evaluate the value of [ 18 F]FDG PET in suspected infections of non-union fractures. We retrospectively evaluated 35 consecutive patients seen between 2000 and 2015 with suspected infection of non-union fractures, treated at a level I trauma center. The patients underwent either [ 18 F]FDG PET/CT (N = 24), [ 18 F]FDG PET (N = 11) plus additional CT (N = 8), or conventional X-ray (N = 3). Imaging findings were correlated with final diagnosis based on intraoperative culture or follow-up. In 13 of 35 patients (37 %), infection was proven by either positive intraoperative tissue culture (N = 12) or positive follow-up (N = 1). [ 18 F]FDG PET revealed 11 true-positive, 19 true-negative, three false-positive, and two false-negative results, indicating sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of 85 %, 86 %, 79 %, 90 %, and 86 %, respectively. The SUV max was 6.4 ± 2.7 in the clinically infected group and 3.0 ± 1.7 in the clinically non-infected group (p <0.01). The SUV ratio was 5.3 ± 3.3 in the clinically infected group and 2.6 ± 1.5 in the clinically non-infected group (p <0.01). [ 18 F]FDG PET differentiates infected from non-infected non-unions with high accuracy in patients with suspected infections of non-union fractures, for whom other clinical findings were inconclusive for a local infection. [ 18 F]FDG PET should be considered for therapeutic management of non-unions. (orig.)

  1. Distraction lengthening of the proximal phalanx in distal thumb amputations.

    Science.gov (United States)

    Cansü, Eren; Ünal, Mehmet Bekir; Parmaksızoğlu, Fatih; Gürcan, Serkan

    2015-01-01

    Thumb amputation is a major cause of hand dysfunction, and the treatment for distal thumb amputations remains controversial. Although finger reconstruction methods using distraction lengthening are known to restore finger length and function, we found no reports in the literature regarding phalangeal lengthening in thumb amputations. We aimed to evaluate proximal phalangeal lengthening in thumb amputations at or near the interphalangeal (IP) joint. We retrospectively evaluated patients who had undergone distraction lengthening of the proximal phalanx of the thumb. All patients underwent osteotomy, either during the initial procedure or as a second-stage procedure. Distraction began 10 days after osteotomy with the use of an external fixator that remained in place until ossification of the gap occurred without bone grafting. Patients were evaluated using the QuickDASH score. Fourteen patients with a mean age of 27 years and a mean follow-up period of 7 years were enrolled. The mean phalangeal lengthening achieved was 20 mm. Ossification occurred at all distraction sites, and the fixators were maintained for a mean of 85 days. The mean healing index was 42.5 days/cm. All 14 patients achieved the desired amount of phalangeal lengthening without major complications such as nonunion, premature union, or gross infection. For reconstruction in cases of distal thumb amputations, distraction lengthening of the proximal phalanx can be used to improve absolute length, web space, and grip distance. The technique is safe and effective, improves functionality/cosmesis, and offers a low complication risk.

  2. Successful treatment of nonunion in severe finger injury with low-intensity pulsed ultrasound (LIPUS: a case report

    Directory of Open Access Journals (Sweden)

    Huber Michaela

    2012-07-01

    Full Text Available Abstract Introduction Severe injuries of the hand or single fingers require immediate treatment but surgical fixation methods are limited depending on soft tissue damage. Thus, it is very common that severe soft tissue damage along with poor osteosynthetic bone fixation results in a delayed healing process or nonunion. Low-intensity pulsed ultrasound (LIPUS has been proven to stimulate bone formation in in vitro studies and also to significantly accelerate nonunion healing in animal studies and clinical trials but to date there are no data with respect to nonunion in phalanx fracture. Case presentation We report a case in which we successfully used LIPUS in a 19-year-old Caucasian man with a nonunion of his ring finger after injury and first treatment with K-wire osteosynthesis. Conclusion We recommend that LIPUS be considered as an option to treat nonunions in fractures of the hand, especially because it is a soft tissue conserving method with a good functional result.

  3. 2D Stabilised analytic signal method in DC pole-pole potential data ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    synthetic error prone secondary pole-pole potential data. 1. Introduction. Analytical signal .... The meaning of the rest of the parameters is self- evident. The three ..... interpretation using 3-D analytic signal; Geophysics 57. 116–125. Starostenko ...

  4. Sport related stress fracture of the clavicle with non-union: Case report and review

    Science.gov (United States)

    Constantinou, Demitri; Kastanos, Konstantinos

    2008-01-01

    Stress fractures are relatively uncommon sports injuries and when they do occur, are mostly found in the lower limb. Stress fractures of the clavicle are particularly rare, having been described in a number of non-sport related pathologies, such as nervous tics and post radical neck dissection. In sport, there have only been seven cases reported in the literature. We report on a clavicle stress fracture in a 47-year-old male, partaking in recreational weight lifting activities. This is the first reported case of a non-union stress fracture of the clavicle. The patient underwent an open reduction and internal fixation and made a full recovery. PMID:21264151

  5. Non-unions force wage cut-backs in pipeline industry

    Energy Technology Data Exchange (ETDEWEB)

    Bain, D

    1984-03-01

    Faced with another year of high unemployment and shrinking markets, Western Canada's unionized pipeline construction trades have taken a step toward stabilizing the industry. The unions have struck a bargain to combat an increasing number of non-union open shops. Management and labor cooperated to insure that the unions regain their share of the pipeline construction market. The pipeline construction boom has ended, with an overcapacity, a downturn in sales, and few major projects on the drawing boards. The bargains included wage reductions of 30%, daily living allowance reductions of nearly 50%, the elimination of double time, and the use of composite crews.

  6. Thoracic Outlet Syndrome in a Volleyball Player Due to Nonunion of the First Rib Fracture.

    Science.gov (United States)

    Puttmann, Kathleen T; Satiani, Bhagwan; Vaccaro, Patrick

    2016-11-01

    Fracture of the first rib with ensuing callus formation is a rare cause of thoracic outlet syndrome. We report a case of a 17-year-old female volleyball player who presented with months of chronic arm pain. Radiographic imaging demonstrated nonunion fracture of the first rib. Physical therapy had been unsuccessful in relieving the pain, and surgical management was performed with resection of the first rib through a transaxillary approach with complete resolution of symptoms. Inflammation surrounding such fractures may destroy tissue planes, making dissection more technically difficult.

  7. The treatment of infected nonunion of the tibia following intramedullary nailing by the Ilizarov method.

    Science.gov (United States)

    Megas, Panagiotis; Saridis, Alkis; Kouzelis, Antonis; Kallivokas, Alkiviadis; Mylonas, Spyros; Tyllianakis, Minos

    2010-03-01

    The purpose of this study was to demonstrate the effectiveness of the Ilizarov method and circular external fixator in order to eradicate the infection and restore bone union, limb anatomy and functionality in cases with infected nonunion of the tibia following intramedullary nailing. During 7 years nine patients suffering from infected nonunion of the tibia after intramedullary nailing were treated in our department. The series comprised seven men and two women with an average age of 39.7 years (range 21-75 years). The patients had previously undergone an average of 4.8 operations (range 3-6 operations). Active purulent bone infection occurred in all nine patients. Bone defect was present in all patients with a mean size of 5 cm (range 2-12 cm). In three cases with bone defect less than 2 cm, monofocal compression osteosynthesis technique was used. In the rest cases where bone defect exceeded 2 cm, bifocal consecutive distraction-compression osteosynthesis technique was applied. Three patients required a local gastrocnemius flap. The mean follow-up period was 26.6 months (range 13-42 months). Results were evaluated using Paley's functional and radiological scoring system. Bone union was achieved in all nine patients without recurrence of infection during the follow-up period. Bone results were graded as excellent in five cases and good in the rest four cases. Functional results were graded as excellent in three cases, good in four and fare in two cases. Mean external fixation time was 187.4 days (range 89-412 days) and mean lengthening index was 32 days/cm (range 27-39 days/cm). Complications observed included eight grade II pin tract infections, axial deformity at the lengthening site in two cases and at the nonunion site in another two cases. Ankle joint stiffness was detected in five cases. The Ilizarov method may be an effective method in infected nonunions of the tibia following intramedullary nailing. Copyright 2009 Elsevier Ltd. All rights reserved.

  8. Surgical treatment of proximal humerus fractures using PHILOS plate

    Directory of Open Access Journals (Sweden)

    Vijay Sharma

    2014-10-01

    Full Text Available 【Abstract】Objective: To evaluate functional outcome and complications of open reduction and internal fixation with proximal humeral internal locking system (PHILOS plate for proximal humerus fractures. Methods: We reviewed 51 patients who underwent open reduction and internal fixation with PHILOS plate between the years 2007 to 2012. There were 35 men and 16 women with a mean age of 38 years (range 24-68. There were 41 patients in the age group of <60 years and 10 patients in the age group of >60 years. According to Neer classification system, 8, 15 and 23 patients had 2-part, 3-part, and 4-part fractures, respectively and 5 patients had 4-part fracture dislocation. All surgeries were carried out at our tertiary care trauma centre. Functional evaluation of the shoulder at final follow-up was done using Constant-Murley score. Results: The mean follow-up period was 30 months (range 12-44 months. Two patients were lost to followup. Of the remaining 49 patients, all fractures were united clinically and radiologically. The mean time for radiological union was 12 weeks (range 8-20 weeks. At the final follow-up the mean Constant-Murley score was 79 (range 50-100. The results were excellent in 25 patients, good in 13 patients, fair in 6 atients and poor in 5 patients. During the follow-up, four cases of varus malunion, one case of subacromial impingement, one case of deep infection, one case of intraarticular screw penetration and one case of failure of fi xation were noted. No cases of avascular necrosis, hardware failure, locking screw loosening or nonunion were noted. Conclusion: PHILOS provides stable fixation in proximal humerus fractures. To prevent potential complications like avascular necrosis, meticulous surgical dissection to preserve vascularity of humeral head is necessary. Key words: Proximal humerus fracture; Fracture fixation, internal; Proximal humeral internal locking system

  9. Mesenchymal Stromal Cells Implantation in Combination with Platelet Lysate Product Is Safe for Reconstruction of Human Long Bone Nonunion.

    Science.gov (United States)

    Labibzadeh, Narges; Emadedin, Mohsen; Fazeli, Roghayeh; Mohseni, Fatemeh; Hosseini, Seyedeh Esmat; Moghadasali, Reza; Mardpour, Soura; Azimian, Vajiheh; Ghorbani Liastani, Maede; Mirazimi Bafghi, Ali; Baghaban Eslaminejad, Mohamadreza; Aghdami, Nasser

    2016-01-01

    Nonunion is defined as a minimum of 9 months since injury without any visible progressive signs of healing for 3 months. Recent literature has shown that the application of mesenchymal stromal cells is safe, in vitro and in vivo, for treating long bone nonunion. The present study was performed to investigate the safety of mesenchymal stromal cell (MSC) implantation in combination with platelet lysate (PL) product for treating human long bone nonunion. In this case series clinical trial, orthopedic surgeons visited eighteen patients with long bone nonunion, of whom 7 complied with the eligibility criteria. These patients received mesenchymal stromal cells (20 million cells implanted once into the nonunion site using a fluoroscopic guide) in combination with PL product. For evaluation of the effects of this intervention all the patients were followed up by taking anterior-posterior and lateral X-rays of the affected limb before and 1, 3, 6, and 12 months after the implantation. All side effects (local or systemic, serious or non-serious, related or unrelated) were observed during this time period. From a safety perspective the MSC implantation in combination with PL was very well tolerated during the 12 months of the trial. Four patients were healed; based on the control Xray evidence, bony union had occurred. Results from the present study suggest that the implantation of bone marrow-derived MSCs in combination with PL is safe for the treatment of nonunion. A double blind, controlled clinical trial is required to assess the efficacy of this treatment (Registration Number: NCT01206179).

  10. Perceived safety climate, job demands, and coworker support among union and nonunion injured construction workers.

    Science.gov (United States)

    Gillen, Marion; Baltz, Davis; Gassel, Margy; Kirsch, Luz; Vaccaro, Diane

    2002-01-01

    This study evaluated injured construction workers' perceptions of workplace safety climate, psychological job demands, decision latitude, and coworker support, and the relationship of these variables to the injury severity sustained by the workers. Injury severity was assessed using the Health Assessment Questionnaire (HAQ), which evaluates functional limitations. Worker perceptions of workplace variables were determined by two instruments: (a) the Safety Climate Measure for Construction Sites and (b) the Job Content Questionnaire (JCQ). The overall model explained 23% of the variance in injury severity, with unique contributions provided by union status, the Safety Climate Score, and Psychological Job Demands. A positive significant correlation was found between injury severity and the Safety Climate Scores (r = .183, P = .003), and between the Safety Climate Scores and union status (r = .225, P safety climate on 5 of the 10 safety climate items. Union workers were more likely than nonunion workers to: (a) perceive their supervisors as caring about their safety; (b) be made aware of dangerous work practices; (c) have received safety instructions when hired; (d) have regular job safety meetings; and (e) perceive that taking risks was not a part of their job. However, with regard to the 49-item JCQ, which includes Coworker Support, the responses between union and nonunion workers were very similar, indicating an overall high degree of job satisfaction. However, workers who experienced their workplace as more safe also perceived the level of management (r = -.55, P demands, need to be identified.

  11. Metrópoles desgovernadas

    Directory of Open Access Journals (Sweden)

    Erminia Maricato

    2011-04-01

    Full Text Available Apesar de sua importância econômica, política, social, demográfica, cultural, territorial e ambiental, há, nas metrópoles brasileiras, uma significativa falta de governo, evidenciada pelas incipientes iniciativas de cooperação administrativa intermunicipal e federativa. Este artigo aborda as mudanças estruturais - no processo de urbanização/ metropolização - devidas à reestruturação produtiva do capitalismo global, e, na escala nacional, trata da mudança no marco institucional - jurídico/político - que passou de concentrador e centralizador, durante o regime militar, para descentralizador e esvaziado, após a Constituição de 1988. O recuo verificado nas políticas sociais durante os anos 1980 e 1990, notadamente em transporte, habitação e saneamento, além do desmonte dos organismos metropolitanos, conduziu nossas metrópoles a um destino de banalização das tragédias urbanas. Em que pese sua urgência, a questão metropolitana não sensibiliza nenhuma força política ou instituição que lhe atribua lugar de destaque na agenda nacional.Despite its economic, political, social, demographic, cultural, territorial and environmental importance, there is a significant lack of government in the brazilian metropolises, evidenced by the incipient initiatives of intermunicipal and federative administrative cooperation. This article analyses the structural changes - in the process of urbanization/metropolization - due to the productive restructuring of global capitalism, and, in a national scale, analyses the change in the institutional mark - legal/political - which passed from concentrator and centralizer, during the Military Regimen, to decentralized and emptied, after 1988 Constitution. The downturn verified in social policies during the years 1980 and 1990, notably in transport, housing and sanitation, besides the dismantling of the metropolitan agencies, has led our cities to the trivialization of urban tragedies. Despite

  12. Holography with a Landau pole

    Energy Technology Data Exchange (ETDEWEB)

    Faedo, Antón F. [Departament de Física Quántica i Astrofísica and Institut de Ciències del Cosmos (ICC), Universitat de Barcelona, Martí i Franquès 1, ES-08028, Barcelona (Spain); Mateos, David [Departament de Física Quántica i Astrofísica and Institut de Ciències del Cosmos (ICC), Universitat de Barcelona, Martí i Franquès 1, ES-08028, Barcelona (Spain); Institució Catalana de Recerca i Estudis Avançats (ICREA), Passeig Lluís Companys 23, ES-08010, Barcelona (Spain); Pantelidou, Christiana [Departament de Física Quántica i Astrofísica and Institut de Ciències del Cosmos (ICC), Universitat de Barcelona, Martí i Franquès 1, ES-08028, Barcelona (Spain); Tarrío, Javier [Physique Théorique et Mathématique, Université Libre de Bruxelles (ULB), and International Solvay Institutes, Campus de la Plaine CP 231, B-1050, Brussels (Belgium)

    2017-02-08

    Holography for UV-incomplete gauge theories is important but poorly understood. A paradigmatic example is d=4, N=4 super Yang-Mills coupled to N{sub f} quark flavors, which possesses a Landau pole at a UV scale Λ{sub LP}. The dual gravity solution exhibits a UV singularity at a finite proper distance along the holographic direction. Despite this, holographic renormalization can be fully implemented via analytic continuation to an AdS solution. The presence of a UV cut-off manifests itself in several interesting ways. At energies E≪Λ{sub LP} no pathologies appear, as expected from effective field theory. In contrast, at scales E≲Λ{sub LP} the gravitational potential becomes repulsive, and at temperatures T≲Λ{sub LP} the specific heat becomes negative. Although we focus on N=4 super Yang-Mills with flavor, our qualitative results apply to a much more general class of theories, since they only depend on the fact that the metric near the UV singularity is a hyper-scaling violating metric with exponent θ>d−1.

  13. Holography with a Landau pole

    International Nuclear Information System (INIS)

    Faedo, Antón F.; Mateos, David; Pantelidou, Christiana; Tarrío, Javier

    2017-01-01

    Holography for UV-incomplete gauge theories is important but poorly understood. A paradigmatic example is d=4, N=4 super Yang-Mills coupled to N f quark flavors, which possesses a Landau pole at a UV scale Λ LP . The dual gravity solution exhibits a UV singularity at a finite proper distance along the holographic direction. Despite this, holographic renormalization can be fully implemented via analytic continuation to an AdS solution. The presence of a UV cut-off manifests itself in several interesting ways. At energies E≪Λ LP no pathologies appear, as expected from effective field theory. In contrast, at scales E≲Λ LP the gravitational potential becomes repulsive, and at temperatures T≲Λ LP the specific heat becomes negative. Although we focus on N=4 super Yang-Mills with flavor, our qualitative results apply to a much more general class of theories, since they only depend on the fact that the metric near the UV singularity is a hyper-scaling violating metric with exponent θ>d−1.

  14. Utility poles not affected by CCA decision

    Energy Technology Data Exchange (ETDEWEB)

    De Venzio, H. [Arch Wood Protection Canada, Mississauga, ON (Canada)

    2002-08-01

    A voluntary decision by industry to move non-industrial use of treated lumber products away from pressure-treated wood containing chromated copper arsenate (CCA) preservative was announced by the Environmental Protection Agency on February 12, 2002. Although new alternative wood preservatives would be used, this decision does not affect utility poles, which will continue to be sold and installed. The author provides a brief historical outline concerning the creation of CCA in 1933 and its subsequent uses. CCA has many advantages, including clean surface of the poles, ground line treatment that is not required thus eliminating the requirement to rotate the poles during extended storage periods. Conductivity is low, as is corrosivity without affecting the bending characteristics of the wood. The injection of a refined hydrocarbon oil emulsion in the outer layer of the pole after the treatment with CCA is offered by some pole producers to facilitate gaff penetration. Sawing, drilling and nailing are also made easier. Water repellents can be added to the treating solution to improve climbability, slowing down the absorption and release of moisture. Warranties, extending for 50-year periods, are offered by some companies against wood-destroying organisms. The North American Wood Pole Coalition (NAWPC) was formed in 1998 to promote the use of wood poles, and publishes brochures and technical bulletins to that effect.

  15. Geometric Modelling of Octagonal Lamp Poles

    Science.gov (United States)

    Chan, T. O.; Lichti, D. D.

    2014-06-01

    Lamp poles are one of the most abundant highway and community components in modern cities. Their supporting parts are primarily tapered octagonal cones specifically designed for wind resistance. The geometry and the positions of the lamp poles are important information for various applications. For example, they are important to monitoring deformation of aged lamp poles, maintaining an efficient highway GIS system, and also facilitating possible feature-based calibration of mobile LiDAR systems. In this paper, we present a novel geometric model for octagonal lamp poles. The model consists of seven parameters in which a rotation about the z-axis is included, and points are constrained by the trigonometric property of 2D octagons after applying the rotations. For the geometric fitting of the lamp pole point cloud captured by a terrestrial LiDAR, accurate initial parameter values are essential. They can be estimated by first fitting the points to a circular cone model and this is followed by some basic point cloud processing techniques. The model was verified by fitting both simulated and real data. The real data includes several lamp pole point clouds captured by: (1) Faro Focus 3D and (2) Velodyne HDL-32E. The fitting results using the proposed model are promising, and up to 2.9 mm improvement in fitting accuracy was realized for the real lamp pole point clouds compared to using the conventional circular cone model. The overall result suggests that the proposed model is appropriate and rigorous.

  16. Tree-loop duality relation beyond single poles

    Energy Technology Data Exchange (ETDEWEB)

    Bierenbaum, Isabella [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik; Buchta, Sebastian; Draggiotis, Petros; Malamos, Ioannis; Rodrigo, German [Valencia Univ. Paterna (Spain). Inst. de Fisica Corpuscular

    2012-11-15

    We develop the Tree-Loop Duality Relation for two- and three-loop integrals with multiple identical propagators (multiple poles). This is the extension of the Duality Relation for single poles and multi-loop integrals derived in previous publications. We prove a generalization of the formula for single poles to multiple poles and we develop a strategy for dealing with higher-order pole integrals by reducing them to single pole integrals using Integration By Parts.

  17. Proximal femoral fractures: Principles of management and review of literature

    Science.gov (United States)

    Mittal, Ravi; Banerjee, Sumit

    2012-01-01

    Purpose The purpose of this study was to review the principles involved in the management of proximal femoral fractures as reported in the literature. Methods: A medical literature search in the MEDLINE (PubMed) and Cochrane database was undertaken to review strategies and principles in proximal femoral fracture treatment. Randomized control trials and meta analysis were given preference while case reports/small series were rejected. Results and conclusions: Early anatomical reduction and surgical fixation remains the best option to reduce the risk of complications like non-union and avascular necrosis in treating fracture neck femurs. Cancellous screws continue to be the preferred treatment for fixation of neck femur fractures in younger population until the benefit of using sliding hip screws is validated by large multicentric studies. In the geriatric age group, early prosthetic replacement brings down the mortality and morbidity associated with neck femur fractures. Sliding hip screw (DHS) is the best available option for stable inter trochanteric fractures. The use of intramedullary nails e.g. PFN is beneficial in treating inter trochanteric fractures with comminution and loss of lateral buttress. Intramedullary implants have been proven to have increased success rates in subtrochanteric fractures and should be preferred over extramedullary plate fixation systems. PMID:25983451

  18. Outcome of nonunion fractures in dogs treated with fixation, compression resistant matrix, and recombinant human bone morphogenetic protein-2.

    Science.gov (United States)

    Massie, Anna M; Kapatkin, Amy S; Fuller, Mark C; Verstraete, Frank J M; Arzi, Boaz

    2017-03-20

    To report the use of compression resistant matrix (CRM) infused with recombinant human bone morphogenetic protein (rhBMP-2) prospectively in the healing of nonunion long-bone fractures in dogs. A longitudinal cohort of dogs that were presented with nonunion fractures were classified and treated with CRM soaked with rhBMP-2 and fracture fixation. They were followed with serial radiographs and evaluated for healing times and complications according to the time frame and definitions previously established for orthopaedic clinical cases. Eleven nonunion fractures in nine dogs were included. Median healing time was 10 weeks (range: 7-20 weeks). Major perioperative complications due to bandage morbidity were encountered in two of 11 limbs and resolved. All other complications were minor. They occurred perioperatively in eight of 11 limbs. Minor follow-up complications included short-term in one of two limbs, mid-term in one of three, and long-term in four of five limbs. Nine limbs returned to full function and two limbs returned to acceptable function at the last follow-up. Nonunion fractures given a poor prognosis via standard-of-care treatment were successfully repaired using CRM with rhBMP-2 accompanying fixation. These dogs, previously at high risk of failure, returned to full or acceptable function.

  19. Negligence claims following non-union and malunion of long bone fractures: An analysis of 15 years of data.

    Science.gov (United States)

    Metcalfe, C W; Harrison, W D; Nayagam, S; Narayan, B

    2016-10-01

    Non-unions and malunions are recognised to be complications of the treatment of long bone fractures. No previous work has looked at the implications of these complications from a medicolegal perspective. A complete database of litigation claims in Trauma and Orthopaedic Surgery was obtained from the NHS Litigation Authority. Two separate modalities of the treatment of long bone fractures were examined i) non-union and ii) acquired deformity. The type of complaint, whether defended or not, and costs were analysed. There were claims of which 97 related to non-union and 32 related to postoperative limb deformity. The total cost was £8.2 million over a 15-year period in England and Wales. Femoral and tibial non-unions were more expensive particularly if they resulted in amputation. Rotational deformity cost nearly twice as much as angulation deformities. The cosmetic appearances of rotational malalignment and amputation results in higher compensation; this reinforces an outward perception of outcome as being more important than harmful effects. Notwithstanding the limitations of this database, there are clinical lessons to be gained from these litigation claims. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  20. One-stage lengthening using a locked nailing technique for distal femoral shaft nonunions associated with shortening.

    Science.gov (United States)

    Wu, Chi-Chuan; Lee, Zhon-Liau

    2004-02-01

    To assess the effectiveness of a one-stage lengthening using a locked nail technique for the treatment of distal femoral shaft nonunions associated with shortening. Retrospective. University hospital. During a 6-year period, 36 distal femoral shaft nonunions associated with shortening (>1.5 cm) were treated by the one-stage lengthening technique. Indications for this technique were distal femoral shaft aseptic or quiescent infected nonunions, 1.5-5 cm shortening, and a fracture level suitable for the insertion of two distal locked screws. The surgical technique involved skeletal traction using the femoral condyle, local débridement, lengthening by lengthening was 2.5 cm (range 1.5-3.5 cm). One-stage lengthening using the locked nailing technique to treat distal femoral shaft nonunions associated with shortening can achieve a high success rate and low complication rate. The key to successful treatment is the patient's complete cooperation with strictly protected weight bearing until the fracture has healed.

  1. Cold Hole Over Jupiter's Pole

    Science.gov (United States)

    2002-01-01

    Observations with two NASA telescopes show that Jupiter has an arctic polar vortex similar to a vortex over Earth's Antarctica that enables depletion of Earth's stratospheric ozone.These composite images of Jupiter's north polar region from the Hubble Space Telescope (right) and the Infrared Telescope Facility (left) show a quasi-hexagonal shape that extends vertically from the stratosphere down into the top of the troposphere. A sharp temperature drop, compared to surrounding air masses, creates an eastward wind that tends to keep the polar atmosphere, including the stratospheric haze, isolated from the rest of the atmosphere.The linear striations in the composite projections are artifacts of the image processing. The area closest to the pole has been omitted because it was too close to the edge of the planet in the original images to represent the planet reliably.The composite on the right combines images from the Wide Field and Planetary Camera 2 of the Hubble Space Telescope taken at a wavelength of 890 nanometers, which shows stratospheric haze particles.The sharp boundary and wave-like structure of the haze layer suggest a polar vortex and a similarity to Earth's stratospheric polar clouds. Images of Jupiter's thermal radiation clinch that identification. The composite on the left, for example, is made from images taken with Jet Propulsion Laboratory's Mid-Infrared Large-Well Imager at NASA's Infrared Telescope Facility at a wavelength of 17 microns. It shows polar air mass that is 5 to 6 degrees Celsius (9 to 10 degrees Fahrenheit) colder than its surroundings, with the same border as the stratospheric haze. Similar observations at other infrared wavelengths show the cold air mass extends at least as high as the middle stratosphere down to the top of the troposphere.These images were taken Aug. 11 through Aug. 13, 1999, near a time when Jupiter's north pole was most visible from Earth. Other Infrared Telescope Facility images at frequencies sensitive to the

  2. Failed Surgical Management of Acute Proximal Fifth Metatarsal (Jones) Fractures: A Retrospective Case Series and Literature Review.

    Science.gov (United States)

    Granata, Jaymes D; Berlet, Gregory C; Philbin, Terrence M; Jones, Grant; Kaeding, Christopher C; Peterson, Kyle S

    2015-12-01

    Nonunion, delayed union, and refracture after operative treatment of acute proximal fifth metatarsal fractures in athletes is uncommon. This study was a failure analysis of operatively managed acute proximal fifth metatarsal fractures in healthy athletes. We identified 149 patients who underwent operative treatment for fifth metatarsal fractures. Inclusion criteria isolated skeletally mature, athletic patients under the age of 40 with a minimum of 1-year follow-up. Patients were excluded with tuberosity fractures, fractures distal to the proximal metaphyseal-diaphyseal region of the fifth metatarsal, multiple fractures or operative procedures, fractures initially treated conservatively, and medical comorbidities/risk factors for nonunion. Fifty-five patients met the inclusion/exclusion criteria. Four (7.3%) patients required a secondary operative procedure due to refracture. The average time to refracture was 8 months. All refractures were associated with bent screws and occurred in male patients who participated in professional basketball, professional volleyball, and college football. The average time for release to progressive weight-bearing was 6 weeks. Three patients were revised to a bigger size screw and went on to union. One patient was revised to the same-sized screw and required a second revision surgery for nonunion. All failures were refractures in competitive athletes who were initially treated with small diameter solid or cannulated stainless steel screws. The failures were not associated with early postoperative weight-bearing protocol. Maximizing initial fixation stiffness may decrease the late failure rate in competitive athletes. More clinical studies are needed to better understand risk factors for failure after screw fixation in the competitive, athletic population. Prognostic, Level IV: Case series. © 2015 The Author(s).

  3. Neighborhoods and manageable proximity

    Directory of Open Access Journals (Sweden)

    Stavros Stavrides

    2011-08-01

    Full Text Available The theatricality of urban encounters is above all a theatricality of distances which allow for the encounter. The absolute “strangeness” of the crowd (Simmel 1997: 74 expressed, in its purest form, in the absolute proximity of a crowded subway train, does not generally allow for any movements of approach, but only for nervous hostile reactions and submissive hypnotic gestures. Neither forced intersections in the course of pedestrians or vehicles, nor the instantaneous crossing of distances by the technology of live broadcasting and remote control give birth to places of encounter. In the forced proximity of the metropolitan crowd which haunted the city of the 19th and 20th century, as well as in the forced proximity of the tele-presence which haunts the dystopic prospect of the future “omnipolis” (Virilio 1997: 74, the necessary distance, which is the stage of an encounter between different instances of otherness, is dissipated.

  4. [{sup 18}F]FDG PET accurately differentiates infected and non-infected non-unions after fracture fixation

    Energy Technology Data Exchange (ETDEWEB)

    Wenter, Vera; Albert, Nathalie L.; Brendel, Matthias; Fendler, Wolfgang P.; Bartenstein, Peter [University of Munich, Department of Nuclear Medicine, Munich (Germany); Cyran, Clemens C. [University of Munich, Institute for Clinical Radiology, Munich (Germany); Friederichs, Jan; Mueller, Jan-Philipp; Militz, Matthias; Hungerer, Sven [BG Trauma Center Murnau, Department of Reconstructive Arthroplasty, Murnau (Germany); PMU Salzburg, Paracelsus Medical University, Salzburg (Austria); Hacker, Marcus [University of Vienna, Division of Nuclear Medicine, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria)

    2017-03-15

    Complete fracture healing is crucial for good patient outcomes. A major complication in the treatment of fractures is non-union. The pathogenesis of non-unions is not always clear, although implant-associated infections play a significant role, especially after surgical treatment of open fractures. We aimed to evaluate the value of [{sup 18}F]FDG PET in suspected infections of non-union fractures. We retrospectively evaluated 35 consecutive patients seen between 2000 and 2015 with suspected infection of non-union fractures, treated at a level I trauma center. The patients underwent either [{sup 18}F]FDG PET/CT (N = 24), [{sup 18}F]FDG PET (N = 11) plus additional CT (N = 8), or conventional X-ray (N = 3). Imaging findings were correlated with final diagnosis based on intraoperative culture or follow-up. In 13 of 35 patients (37 %), infection was proven by either positive intraoperative tissue culture (N = 12) or positive follow-up (N = 1). [{sup 18}F]FDG PET revealed 11 true-positive, 19 true-negative, three false-positive, and two false-negative results, indicating sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of 85 %, 86 %, 79 %, 90 %, and 86 %, respectively. The SUV{sub max} was 6.4 ± 2.7 in the clinically infected group and 3.0 ± 1.7 in the clinically non-infected group (p <0.01). The SUV{sub ratio} was 5.3 ± 3.3 in the clinically infected group and 2.6 ± 1.5 in the clinically non-infected group (p <0.01). [{sup 18}F]FDG PET differentiates infected from non-infected non-unions with high accuracy in patients with suspected infections of non-union fractures, for whom other clinical findings were inconclusive for a local infection. [{sup 18}F]FDG PET should be considered for therapeutic management of non-unions. (orig.)

  5. VT Green Mountain Power Pole Data

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) Green Mountain Power (GMP) pole and OVERHEAD linear distribution/sub-transmission model data. THE LINEAR DISTRIBUTION LAYER ONLY INCLUDES OVERHEAD...

  6. The pole tide in deep oceans

    Science.gov (United States)

    Dickman, S. R.

    1990-01-01

    The fluid-dynamical theory of the pole tide is examined by describing the oceanic response to the Chandler wobble and assessing its implications for mantle anelasticity and low-frequency ocean dynamics. The Laplace tide equations accounting for bottom friction are given, and a spherical harmonic approach is delineated in which the time-independent portion of the tide height is expanded. Pole-tide height and related inertia products are linearly proportional to wobble amplitude, and the final equations are modified to account for mantle elasticity and oceanic loading. Results for pole tide effects are given for various earth models with attention to the role of boundary constraints. A dynamic effect is identified which lengthens the Chandler period by about 1 day more than static lengthening, a contribution that suggests a vigorous low-frequency response. The values derived are shown to agree with previous models that do not incorporate the effects of the pole tide.

  7. A STUDY ON PROXIMAL HUMERAL FRACTURES STABILISED WITH PHILOS PLATE

    Directory of Open Access Journals (Sweden)

    Praveen Sivakumar K

    2017-02-01

    Full Text Available BACKGROUND Techniques for treating complex proximal humeral fractures vary and include fixations using tension bands, percutaneous pins, bone suture, T-plates, intramedullary nails, double tubular plates, hemiarthroplasty, plant tan humerus fixator plates, Polaris nails and blade plates. Complications of these techniques include cutout or back out of the screws and plates, avascular necrosis, nonunion, malunion, nail migration, rotator cuff impairment and impingement syndromes. Insufficient anchorage from conventional implants may lead to early loosening and failure, especially in osteoporotic bones. In general, nonoperative treatment of displaced three and four-part fractures of the proximal humerus leads to poor outcome due to intraarticular nature of injury and inherent instability of the fragments. Comminuted fractures of the proximal humerus are at risk of fixation failure, screw loosening and fracture displacement. Open reduction and internal fixation with conventional plate and screws has been associated with unacceptably high incidence of screw pull out. PHILOS (the proximal humeral internal locking system plate is an internal fixation system that enables angled stabilisation with multiple interlocking screws for fractures of the proximal humerus. MATERIALS AND METHODS 30 patients with proximal humerus fractures who were admitted in the Department of Orthopaedics, Government General Hospital, Kakinada, during the period November 2014 - November 2016 were taken up for study according to inclusion criteria. All patients were treated with PHILOS plate. These proximal humerus fractures were classified according to Neer’s classification. Patients were followed up at 6 weeks, 12 weeks and 6 months’ interval. Functional outcomes for pain, range of motion and muscle power and function were assessed using the Constant-Murley scoring system. Collected data analysed with independent t-test and ANNOVA test. RESULTS The outcome of the study was 1

  8. On pole structure assignment in linear systems

    Czech Academy of Sciences Publication Activity Database

    Loiseau, J.-J.; Zagalak, Petr

    2009-01-01

    Roč. 82, č. 7 (2009), s. 1179-1192 ISSN 0020-7179 R&D Projects: GA ČR(CZ) GA102/07/1596 Institutional research plan: CEZ:AV0Z10750506 Keywords : linear systems * linear state feedback * pole structure assignment Subject RIV: BC - Control Systems Theory Impact factor: 1.124, year: 2009 http://library.utia.cas.cz/separaty/2009/AS/zagalak-on pole structure assignment in linear systems.pdf

  9. Application of Local Vibrations in Delayed and Non-Union Fractures: a Case Study

    Science.gov (United States)

    Trombetta, Chiara; Abundo, Paolo; Foti, Calogero; Rosato, Nicola

    2011-02-01

    The aim of the study was to assess the efficacy of local vibration treatments (LV) in delayed-union and non-union fractures, through therapeutic exercise vibration (TEV) practice, analysing the radiological trend. The Medical Engineering Service of the Fondazione Policlinico Tor Vergata in collaboration with the Chair-Department of Rehabilitation Medicine of the University of Rome Tor Vergata and the Boscosystem company, is developing a device dedicated to LV application, to favour bone regeneration and muscle strengthening. This case report analyses the bone activity of a male patient presenting a right tibial fracture, treated with TEV. At the end of the TEV program, clinical results confirmed independent ambulation with disappearance of perimalleolar edema, while radiographic images revealed the presence of bone repair activity around the fracture line.

  10. Application of Local Vibrations in Delayed and Non-Union Fractures: a Case Study

    International Nuclear Information System (INIS)

    Trombetta, Chiara; Abundo, Paolo; Foti, Calogero; Rosato, Nicola

    2011-01-01

    The aim of the study was to assess the efficacy of local vibration treatments (LV) in delayed-union and non-union fractures, through therapeutic exercise vibration (TEV) practice, analysing the radiological trend. The Medical Engineering Service of the Fondazione Policlinico Tor Vergata in collaboration with the Chair-Department of Rehabilitation Medicine of the University of Rome Tor Vergata and the Boscosystem company, is developing a device dedicated to LV application, to favour bone regeneration and muscle strengthening. This case report analyses the bone activity of a male patient presenting a right tibial fracture, treated with TEV. At the end of the TEV program, clinical results confirmed independent ambulation with disappearance of perimalleolar edema, while radiographic images revealed the presence of bone repair activity around the fracture line.

  11. Nonunion of the femoral neck: Possibilities and limitations of the various treatment modalities

    Directory of Open Access Journals (Sweden)

    Raaymakers Ernst

    2008-01-01

    Full Text Available Nowadays in cases of nonunions of the femoral neck, the surgeon is tempted to perform prosthetic replacement of the hip, more so if there is also evidence of avascular necrosis of the head of femur. This provides rapid pain relief and allows early mobilization. However, long-term results of hip arthroplasties, especially in younger people and in the presence of osteopenia, are not always as expected; and a less radical approach is worth considering. The intertrochanteric valgization osteotomy, described by Pauwels, is an excellent alternative for healthy patients up to 65 years of age with a nonunion of the femoral neck. A union rate of 80-90% of the nonunion is described by most authors. Leg length inequallity, rotational and angular deformities can be corrected at the same time. During the period 1973-1995, we performed valgization osteotomy according to Pauwels in 66 patients of, 18-72 years old (mean 49.5 years. 24 (37% of our patients died 4 months to 24 years (mean: 9.5 years after the operation. Union of the femoral neck was achieved in 58 (88% of the 66 patients; union of the osteotomy in 65 patients (99%. A good or excellent result was achieved in 62% (23 uneventful and 13 with healed, necrosis/arthrosis without need for further treatment of our patients. However, the method has its limits. We feel if there is too little bone stock inside the femoral head, a valgization osteotomy does not give good result. The radiographic signs of avascular necrosis in patients over 30 years of age is considered a contraindication for an osteotomy. However our results show that it is worthwhile trying to save the joint of young patients even in case of a segmental collapse. In the race between revascularization and collapse, often revascularization is the winner. We deliberately give nature its chance and don′t rely on the result of bleeding from drill holes in the head, nuclear scans and other methods to estimate vascularity. A secondary total hip

  12. Treatment of midshaft clavicular nonunion with plate fixation and autologous bone grafting

    DEFF Research Database (Denmark)

    Olsen, Bo Sanderhoff; Vaesel, M T; Søjbjerg, Jens Ole

    1995-01-01

    We studied the results of 16 consecutive midshaft clavicular nonunions operated on at the Shoulder and Elbow Clinic during the period from 1990 to 1993. All patients were treated with rigid 3.5 mm plate fixation and autologous cancellous bone grafting. Union of the fractures was achieved in all...... except one case, with a reconstruction ratio (restoration of bone length) of 0.96 (range 0.88 to 1.03). At follow-up 12 of 16 patients had returned to their preinjury activity level and according to the Constant score had obtained an excellent result. Two patients were graded as good, one as fair......, and one had a failure. Thirteen of 16 patients were satisfied with the cosmetic outcome, assessing their cosmetic result as either good or excellent. Rigid plate fixation and restoration of clavicular length with autologous cancellous bone graft is recommended for the treatment of symptomatic clavicular...

  13. Reamed intramedullary exchange nailing in the operative treatment of aseptic tibial shaft nonunion.

    Science.gov (United States)

    Hierholzer, Christian; Friederichs, Jan; Glowalla, Claudio; Woltmann, Alexander; Bühren, Volker; von Rüden, Christian

    2017-08-01

    The aim of this study was to evaluate a standardized treatment protocol regarding the rate of secondary bone union, complications, and functional outcome. This study was started as a prospective study in a single Level I Trauma Centre between 2003 and 2012. The study group consisted of 188 patients with the diagnosis of an aseptic tibial shaft nonunion. Exchange nailing was performed following a standardized surgical protocol. Long-term follow-up was analyzed for rate of bone healing and functional outcome. Osseous healing was achieved in 182 out of 188 patients (97 %). In 165 out of 188 patients (88 %), bone healing was observed timely and uneventfully after a single exchange nailing procedure. An open approach was necessary in 32 patients (17 %). Twenty-three patients (12 %) required additional therapy such as extracorporeal shock wave therapy. Post-operative complications were observed in seven patients (4 %). Almost all patients demonstrated osseous healing within 12 months, with the majority of osseous healing occurring within six months. A relevant shortening of the fractured tibia was observed in 20 out of 188 patients (11 %). After a median follow-up of 23 months (range 12-45 months), outcome was evaluated using the assessment system of Friedman/Wyman. In summary, 154 out of 188 patients (82 %) had a good functional long-term result. Reamed intramedullary exchange nailing including correction of axis alignment is a safe and effective treatment of aseptic tibial shaft nonunion with a high rate of bone healing and a good radiological and functional long-term outcome.

  14. Proximal collagenous gastroenteritides:

    DEFF Research Database (Denmark)

    Nielsen, Ole Haagen; Riis, Lene Buhl; Danese, Silvio

    2014-01-01

    AIM: While collagenous colitis represents the most common form of the collagenous gastroenteritides, the collagenous entities affecting the proximal part of the gastrointestinal tract are much less recognized and possibly overlooked. The aim was to summarize the latest information through a syste...

  15. Proximal femoral fractures

    DEFF Research Database (Denmark)

    Palm, Henrik; Teixidor, Jordi

    2015-01-01

    searched the homepages of the national heath authorities and national orthopedic societies in West Europe and found 11 national or regional (in case of no national) guidelines including any type of proximal femoral fracture surgery. RESULTS: Pathway consensus is outspread (internal fixation for un...

  16. Proximate Analysis of Coal

    Science.gov (United States)

    Donahue, Craig J.; Rais, Elizabeth A.

    2009-01-01

    This lab experiment illustrates the use of thermogravimetric analysis (TGA) to perform proximate analysis on a series of coal samples of different rank. Peat and coke are also examined. A total of four exercises are described. These are dry exercises as students interpret previously recorded scans. The weight percent moisture, volatile matter,…

  17. The potential of wood-based composite poles

    Science.gov (United States)

    Todd F. Shupe; Cheng Piao; Chung Y. Hse

    2009-01-01

    Wood-based composite utility poles are receiving increasing attention in the North American pole market. This interest is being driven by many increasing factors such as increasing: (1) disposal costs of solid wood poles, (2) liability and environmental concerns with traditional means of disposal of solid wood poles, (3) cost and concerns of long-term...

  18. Uncemented allograft-prosthetic composite reconstruction of the proximal femur

    Directory of Open Access Journals (Sweden)

    Li Min

    2014-01-01

    Full Text Available Background: Allograft-prosthetic composite can be divided into three groups names cemented, uncemented, and partially cemented. Previous studies have mainly reported outcomes in cemented and partially cemented allograft-prosthetic composites, but have rarely focused on the uncemented allograft-prosthetic composites. The objectives of our study were to describe a surgical technique for using proximal femoral uncemented allograft-prosthetic composite and to present the radiographic and clinical results. Materials and Methods: Twelve patients who underwent uncemented allograft-prosthetic composite reconstruction of the proximal femur after bone tumor resection were retrospectively evaluated at an average followup of 24.0 months. Clinical records and radiographs were evaluated. Results: In our series, union occurred in all the patients (100%; range 5-9 months. Until the most recent followup, there were no cases with infection, nonunion of the greater trochanter, junctional bone resorption, dislocation, allergic reaction, wear of acetabulum socket, recurrence, and metastasis. But there were three periprosthetic fractures which were fixed using cerclage wire during surgery. Five cases had bone resorption in and around the greater trochanter. The average Musculoskeletal Tumor Society (MSTS score and Harris hip score (HHS were 26.2 points (range 24-29 points and 80.6 points (range 66.2-92.7 points, respectively. Conclusions: These results showed that uncemented allograft-prosthetic composite could promote bone union through compression at the host-allograft junction and is a good choice for proximal femoral resection. Although this technology has its own merits, long term outcomes are yet not validated.

  19. Quantum Proximity Resonances

    International Nuclear Information System (INIS)

    Heller, E.J.

    1996-01-01

    It is well known that at long wavelengths λ an s-wave scatterer can have a scattering cross section σ on the order of λ 2 , much larger than its physical size, as measured by the range of its potential. Very interesting phenomena can arise when two or more identical scatterers are placed close together, well within one wavelength. We show that, for a pair of identical scatterers, an extremely narrow p-wave open-quote open-quote proximity close-quote close-quote resonance develops from a broader s-wave resonance of the individual scatterers. A new s-wave resonance of the pair also appears. The relation of these proximity resonances (so called because they appear when the scatterers are close together) to the Thomas and Efimov effects is discussed. copyright 1996 The American Physical Society

  20. Pole shifting with constrained output feedback

    International Nuclear Information System (INIS)

    Hamel, D.; Mensah, S.; Boisvert, J.

    1984-03-01

    The concept of pole placement plays an important role in linear, multi-variable, control theory. It has received much attention since its introduction, and several pole shifting algorithms are now available. This work presents a new method which allows practical and engineering constraints such as gain limitation and controller structure to be introduced right into the pole shifting design strategy. This is achieved by formulating the pole placement problem as a constrained optimization problem. Explicit constraints (controller structure and gain limits) are defined to identify an admissible region for the feedback gain matrix. The desired pole configuration is translated into an appropriate cost function which must be closed-loop minimized. The resulting constrained optimization problem can thus be solved with optimization algorithms. The method has been implemented as an algorithmic interactive module in a computer-aided control system design package, MVPACK. The application of the method is illustrated to design controllers for an aircraft and an evaporator. The results illustrate the importance of controller structure on overall performance of a control system

  1. POLE somatic mutations in advanced colorectal cancer.

    Science.gov (United States)

    Guerra, Joana; Pinto, Carla; Pinto, Diana; Pinheiro, Manuela; Silva, Romina; Peixoto, Ana; Rocha, Patrícia; Veiga, Isabel; Santos, Catarina; Santos, Rui; Cabreira, Verónica; Lopes, Paula; Henrique, Rui; Teixeira, Manuel R

    2017-12-01

    Despite all the knowledge already gathered, the picture of somatic genetic changes in colorectal tumorigenesis is far from complete. Recently, germline and somatic mutations in the exonuclease domain of polymerase epsilon, catalytic subunit (POLE) gene have been reported in a small subset of microsatellite-stable and hypermutated colorectal carcinomas (CRCs), affecting the proofreading activity of the enzyme and leading to misincorporation of bases during DNA replication. To evaluate the role of POLE mutations in colorectal carcinogenesis, namely in advanced CRC, we searched for somatic mutations by Sanger sequencing in tumor DNA samples from 307 cases. Microsatellite instability and mutation analyses of a panel of oncogenes were performed in the tumors harboring POLE mutations. Three heterozygous mutations were found in two tumors, the c.857C>G, p.Pro286Arg, the c.901G>A, p.Asp301Asn, and the c.1376C>T, p.Ser459Phe. Of the POLE-mutated CRCs, one tumor was microsatellite-stable and the other had low microsatellite instability, whereas KRAS and PIK3CA mutations were found in one tumor each. We conclude that POLE somatic mutations exist but are rare in advanced CRC, with further larger studies being necessary to evaluate its biological and clinical implications. © 2017 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  2. Predictors associated with nonunion and symptomatic malunion following non-operative treatment of displaced midshaft clavicle fractures-a systematic review of the literature

    DEFF Research Database (Denmark)

    Jørgensen, Ann Louise; Troelsen, Anders; Ban, Ilija

    2014-01-01

    PURPOSE: The aim of this study was to survey existing literature in order to identify all reported predictors associated with nonunion or symptomatic malunion in adult patients with displaced midshaft clavicle fractures treated non-operatively. METHOD: A systematic literature search in Medline...... was carried out in order to identify publications in English, reporting on predictors for nonunion and malunion in adults with displaced midshaft clavicle fractures. After applying inclusion and exclusion criteria, eight publications were included in this systematic review. RESULTS: A total of 2,117 midshaft...... factors associated with nonunion were identified, six of these (displacement, comminution, shortening, age, gender and smoking) were reported as predictors for nonunion. Outcome definitions varied among the studies. CONCLUSION: The included publications varied greatly in design, sample size, and quality...

  3. Pole lengths influence O2-cost during double poling in highly trained cross-country skiers.

    Science.gov (United States)

    Carlsen, Camilla Høivik; Rud, Bjarne; Myklebust, Håvard; Losnegard, Thomas

    2018-02-01

    In elite cross-country skiing, double poling is used in different terrain. This study compared O 2 -cost and kinematics during double poling with four different pole lengths [self-selected (SS), SS - 5 cm, SS + 5 cm, SS + 10 cm] at Low versus Moderate incline. Thirteen highly trained male cross-country skiers (mean ± SD 23 ± 3 years; 182 ± 4 cm; 77 ± 6 kg) completed eight submaximal trials with roller skis on a treadmill at two conditions: "Low incline" (1.7°; 4.5 m s -1 ) and "Moderate incline" (4.5°; 2.5 m s -1 ) with each of the four pole lengths. O 2 -cost and 3D body kinematics were assessed in each trial. In Low incline, SS + 10 cm induced a lower O 2 -cost than all the other pole lengths [P size (ES) 0.5-0.8], whereas no differences were found between the remaining pole lengths (P > 0.05; ES 0.2-0.4). In Moderate incline, significant differences between all pole lengths were found for O 2 -cost, with SS - 5 cm > SS > SS + 5 cm > SS + 10 cm (P differences in O 2 -cost between SS and the other pole lengths were greater in Moderate incline than Low incline (SS - 5 cm; 1.5%, ES 0.8, SS + 5 cm; 1.3%, ES 1.0, and SS + 10 cm; 1.9%, ES 1.0, all P difference was found in cycle, poling or reposition times between pole lengths. However, at both conditions a smaller total vertical displacement of center of mass was observed with SS + 10 cm compared to the other pole lengths. Increasing pole length from SS - 5 cm to SS + 10 cm during double poling induced lower O 2 -cost and this advantage was greater in Moderate compared to Low incline.

  4. Pole solutions for flame front propagation

    CERN Document Server

    Kupervasser, Oleg

    2015-01-01

    This book deals with solving mathematically the unsteady flame propagation equations. New original mathematical methods for solving complex non-linear equations and investigating their properties are presented. Pole solutions for flame front propagation are developed. Premixed flames and filtration combustion have remarkable properties: the complex nonlinear integro-differential equations for these problems have exact analytical solutions described by the motion of poles in a complex plane. Instead of complex equations, a finite set of ordinary differential equations is applied. These solutions help to investigate analytically and numerically properties of the flame front propagation equations.

  5. PNRA. South-pole directory listing

    OpenAIRE

    Biagioni, Stefania; Carlesi, Carlo; Carpen?, Andrea; Ramorino, Chiara; Rossi, Lucio

    1992-01-01

    In the following all DATA-SET descriptors (DSD) contained in the "South-Pole Directory" (vers. 1992) are listed. The "South-Pole Directory" was a joint project between ENEA and CNR. The IEI/CNR took care of the data digitalization and check and of the english translation (where necessary). The ARF/CNR and the Progetto Antartide/ENEA joined the IEI/CNR in defining the acronyms of the Sensor_Names and of the Source_Names, together with the short and long names for the Data_Centers. Finally, the...

  6. Direct localization of poles of a meromorphic function from measurements on an incomplete boundary

    Science.gov (United States)

    Nara, Takaaki; Ando, Shigeru

    2010-01-01

    This paper proposes an algebraic method to reconstruct the positions of multiple poles in a meromorphic function field from measurements on an arbitrary simple arc in it. A novel issue is the exactness of the algorithm depending on whether the arc is open or closed, and whether it encloses or does not enclose the poles. We first obtain a differential equation that can equivalently determine the meromorphic function field. From it, we derive linear equations that relate the elementary symmetric polynomials of the pole positions to weighted integrals of the field along the simple arc and end-point terms of the arc when it is an open one. Eliminating the end-point terms based on an appropriate choice of weighting functions and a combination of the linear equations, we obtain a simple system of linear equations for solving the elementary symmetric polynomials. We also show that our algorithm can be applied to a 2D electric impedance tomography problem. The effects of the proximity of the poles, the number of measurements and noise on the localization accuracy are numerically examined.

  7. Shape change in the atlas with congenital midline non-union of its posterior arch: a morphometric geometric study.

    Science.gov (United States)

    Ríos, Luis; Palancar, Carlos; Pastor, Francisco; Llidó, Susana; Sanchís-Gimeno, Juan Alberto; Bastir, Markus

    2017-10-01

    The congenital midline non-union of the posterior arch of the atlas is a developmental variant present at a frequency ranging from 0.7% to 3.9%. Most of the reported cases correspond to incidental findings during routine medical examination. In cases of posterior non-union, hypertrophy of the anterior arch and cortical bone thickening of the posterior arches have been observed and interpreted as adaptive responses of the atlas to increased mechanical stress. We sought to determine if the congenital non-union of the posterior arch results in a change in the shape of the atlas. This study is an analysis of the first cervical vertebrae from osteological collections through morphometric geometric techniques. A total of 21 vertebrae were scanned with a high-resolution three-dimensional scanner (Artec Space Spider, Artec Group, Luxembourg). To capture vertebral shape, 19 landmarks and 100 semilandmarks were placed on the vertebrae. Procrustes superimposition was applied to obtain size and shape data (MorphoJ 1.02; Klingenberg, 2011), which were analyzed through principal component analysis (PCA) and mean shape comparisons. The PCA resulted in two components explaining 22.32% and 18.8% of the total shape variance. The graphic plotting of both components indicates a clear shape difference between the control atlas and the atlas with posterior non-union. This observation was supported by statistically significant differences in mean shape comparisons between both types of vertebra (patlas is associated with significant changes in the shape of the vertebra. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Robot-assisted laparoscopic pyeloureterostomy in infants with duplex systems and upper pole hydronephrosis: Variations in double-J ureteral stenting techniques.

    Science.gov (United States)

    Baek, Minki; Au, Jason; Huang, Gene O; Koh, Chester J

    2017-04-01

    We describe our experience with robot-assisted laparoscopic (RAL) pyeloureterostomy in infants with duplex systems and upper pole hydronephrosis with an emphasis on the various double J (DJ) ureteral stent placement techniques. We used our RAL pyeloureterostomy technique in two female infants with duplex systems and upper pole hydronephrosis. For case 1, we introduced the DJ stent and placed it in the recipient lower pole ureter during the robotic operation in an antegrade fashion. For case 2, we inserted the DJ stent during retrograde pyelography prior to the robotic procedure in a retrograde fashion, and the proximal portion of the stent was placed across the anastomosis into the upper pole renal pelvis. Postoperatively, each of the patients were discharged on postoperative day 1 without complications. The postoperative renal ultrasound at 3 months demonstrated marked improvement of the right upper pole hydronephrosis in both patients. RAL pyeloureterostomy represents a minimally invasive option for upper tract reconstruction of duplex systems with upper pole hydronephrosis in infants. The DJ stent can be placed at the beginning or during the procedure. The stent can be placed in the lower pole ureter or across the anastomosis into the upper pole renal pelvis. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  9. Intramedullary stabilization and over-nail lengthening as two-stage treatment of femoral nonunion with shortening. Case study.

    Science.gov (United States)

    Kącki, Wojciech; Jasiewicz, Barbara; Radło, Paweł

    2014-01-01

    Nonunion is one of the most serious complications of long bone fractures. It may be accompanied by a shortening of the segment. The authors describe the case of a 21-year-old woman with a post-traumatic nonunion with shortening of the femur. Treatment was divided into two stages: first, a previously placed nail was removed and new intramedullary stabilization was carried out while bone defects were filled with a bone graft substitute and platelet rich plasma was administered. After the nonunion had healed, the femur was lengthened over an external fixator and an intramedullary nail, resulting in equality of limb length. After eight years of follow-up, the lower limbs remain equal with a properly aligned long axis of the lower limb operated on and a full range of motion in the joints. The treatment strategy described in our article may be an alternative to one-stage surgery if the patient does not consent to it or in the presence of contraindications, but it is associated with a longer treatment time and necessity of additional surgeries.

  10. Proximity friction reexamined

    International Nuclear Information System (INIS)

    Krappe, H.J.

    1989-01-01

    The contribution of inelastic excitations to radial and tangential friction form-factors in heavy-ion collisions is investigated in the frame-work of perturbation theory. The dependence of the form factors on the essential geometrical and level-density parameters of the scattering system is exhibited in a rather closed form. The conditions for the existence of time-local friction coefficients are discussed. Results are compared to form factors from other models, in particular the transfer-related proximity friction. For the radial friction coefficient the inelastic excitation mechanism seems to be the dominant contribution in peripheral collisions. (orig.)

  11. Lower pole renal cut injury due to the iliac wing fracture: A rare case report

    Directory of Open Access Journals (Sweden)

    Çaglar Yildirim

    2015-07-01

    Full Text Available The most frequent causes of blunt genitourinary injuries are falls from heights, motor vehicle accidents and sports injuries. Firearm injuries and penetrating stab wounds are also frequently encountered. Skeletal system traumas in the vicinity of the urogenital system can cause urological organ injuries. Though rarely, renal traumas can be dependent on the kinetic energy of the trauma and the retroperitoneal movement capacity of the kidneys and cannot be explained with the proximity of the kidney to the skeletal system. In cases with high-energy decelerations, renal pedicle and ureteropelvic junction traumas are more frequently observed. Herein, we presented a grade 3 left kidney lower pole injury developed secondary to A2 type pelvic fracture following a high energy deceleration trauma. It should not be forgotten that especially in this type of fractures, injuries of the lower renal pole can occur.

  12. Recurrent hydatosis at the site of non-union humerus fracture

    Directory of Open Access Journals (Sweden)

    Mohsen Nourbakhsh

    2012-01-01

    Full Text Available Hydatid disease is still endemic in several regions of the world and is caused by two species of tapeworms, Echinococcus granulosus and Echinococcus alveolaris. It primary involves liver and lung, and bone involvement is relatively rare (0.2-4%, where it is most commonly seen in the spine. The skeletal involvement is usually due to secondary extension such as hematogenous spread. The disease has usually a silent manifestation until a complication exists; so, many cases are diagnosed intraoperatively. Treatment of hydatid disease because of its bone involvement and spillage of fluid with subsequent contamination seeding is difficult, so it has a high mortality rate and many cases will recur. Therefore, we can prevent these occurrences if we treat hydatid disease completely and in the primary stage. Adjuvant medical treatment, if the diagnosis is known, prevents systemic spread and recurrence. Here, we present a primary recurrent hydatosis at the site of non-union humerus fracture. We have pointed out osseous hydatosis as one of the important differential diagnoses in destructive bone lesions and the necessity of its radical resection.

  13. Atypical Chronic Ankle Instability in a Pediatric Population Secondary to Distal Fibula Avulsion Fracture Nonunion.

    Science.gov (United States)

    El Ashry, Saad R; El Gamal, Tarek A; Platt, Simon R

    Chronic ankle instability is a disabling condition, often occurring as a result of traumatic ankle injury. A paucity of published data is available documenting chronic ankle instability in the pediatric population. Much of the data has been confined to the adult population. We present 2 cases of chronic ankle instability, 1 in a 12-year-old and 1 in a 9-year-old patient. Unlike the typical adult etiology, the cause of instability was a dysfunctional lateral ligamentous complex as a consequence of bony avulsion of the tip of the fibula. Both patients had sustained a twisting injury to the ankle. The fractures failed to unite. The nonunion resulted in dysfunction of the anterior talofibular ligament with consequent chronic ankle instability. At the initial clinical assessment, magnetic resonance imaging was requested for both patients. In patient 1 (12 years old), the fracture was fixed with 2 headless screws and was immobilized in a plaster cast for 6 weeks. In patient 2 (9 years old), because of the small size of the avulsed fragment, fixation was not possible. A modified Gould-Broström procedure was undertaken, facilitating repair of the avulsed fragment using anchor sutures. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Factors associated with nonunion, delayed union, and malunion in foot and ankle surgery in diabetic patients.

    Science.gov (United States)

    Shibuya, Naohiro; Humphers, Jon M; Fluhman, Benjamin L; Jupiter, Daniel C

    2013-01-01

    The incidence of bone healing complications in diabetic patients is believed to be high after foot and ankle surgery. Although the association of hyperglycemia with bone healing complications has been well documented, little clinical information is available to show which diabetes-related comorbidities directly affect bone healing. Our goal was to better understand the risk factors associated with poor bone healing in the diabetic population through an exploratory, observational, retrospective, cohort study. To this end, 165 diabetic patients who had undergone arthrodesis, osteotomy, or fracture reduction were enrolled in the study to assess the risk factors associated with nonunion, delayed union, and malunion after elective and nonelective foot and/or ankle surgery. Bivariate analyses showed that a history of foot ulcer, peripheral neuropathy, and surgery duration were statistically significantly associated with bone healing complications. After adjusting for other covariates, only peripheral neuropathy, surgery duration, and hemoglobin A1c levels >7% were significantly associated statistically with bone healing complications. Of the risk factors we considered, peripheral neuropathy had the strongest association with bone healing complications. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  15. A Visit to the South Pole

    Indian Academy of Sciences (India)

    IAS Admin

    For these reasons, I could not buy many of the essential things .... Geomagnetic South Pole at 78° 27' S, 106° 48' E at an altitude of 3,488 metres on approximately .... Smokers at the station were often found searching for used cigarette butts.

  16. Recent advances in poled optical fibres

    DEFF Research Database (Denmark)

    Pruneri, V.; Margulis, W.; Myrén, N.

    2005-01-01

    A second-order nonlinearity can be induced in optical fibres through poling. We describe accomplishments of the EU project GLAMOROUS in making low-cost high performance electrooptic and nonlinear optical fibre- and waveguide-based components. In particular a comparison with more traditional...

  17. Stabilization, pole placement, and regular implementability

    NARCIS (Netherlands)

    Belur, MN; Trentelman, HL

    In this paper, we study control by interconnection of linear differential systems. We give necessary and sufficient conditions for regular implementability of a-given linear, differential system. We formulate the problems of stabilization and pole placement as problems of finding a suitable,

  18. Quasiparticle pole strength in nuclear matter

    International Nuclear Information System (INIS)

    Poggioli, R.S.; Jackson, A.D.

    1975-01-01

    It is argued that single-particle-like behavior in nuclear matter is much less probable than Brueckner theory suggests. In particular, the quasiparticle pole strength is evaluated for nuclear matter and it is shown that, contrary to the spirit of Brueckner theory, low momentum states play a crucial role in determining the magnitude of z/sub k/sub F/. (auth)

  19. Pole masses of quarks in dimensional reduction

    International Nuclear Information System (INIS)

    Avdeev, L.V.; Kalmykov, M.Yu.

    1997-01-01

    Pole masses of quarks in quantum chromodynamics are calculated to the two-loop order in the framework of the regularization by dimensional reduction. For the diagram with a light quark loop, the non-Euclidean asymptotic expansion is constructed with the external momentum on the mass shell of a heavy quark

  20. Echosonography with proximity sensors

    International Nuclear Information System (INIS)

    Thaisiam, W; Laithong, T; Meekhun, S; Chaiwathyothin, N; Thanlarp, P; Danworaphong, S

    2013-01-01

    We propose the use of a commercial ultrasonic proximity sensor kit for profiling an altitude-varying surface by employing echosonography. The proximity sensor kit, two identical transducers together with its dedicated operating circuit, is used as a profiler for the construction of an image. Ultrasonic pulses are emitted from one of the transducers and received by the other. The time duration between the pulses allows us to determine the traveling distance of each pulse. In the experiment, the circuit is used with the addition of two copper wires for directing the outgoing and incoming signals to an oscilloscope. The time of flight of ultrasonic pulses can thus be determined. Square grids of 5 × 5 cm 2 are made from fishing lines, forming pixels in the image. The grids are designed to hold the detection unit in place, about 30 cm above a flat surface. The surface to be imaged is constructed to be height varying and placed on the flat surface underneath the grids. Our result shows that an image of the profiled surface can be created by varying the location of the detection unit along the grid. We also investigate the deviation in relation to the time of flight of the ultrasonic pulse. Such an experiment should be valuable for conveying the concept of ultrasonic imaging to physical and medical science undergraduate students. Due to its simplicity, the setup could be made in any undergraduate laboratory relatively inexpensively and it requires no complex parts. The results illustrate the concept of echosonography. (paper)

  1. Rotor pole refurbishment for hydrogenerators: insulation problems and solutions

    International Nuclear Information System (INIS)

    Reynolds, R.R.; Rux, L.

    2005-01-01

    Rotor poles for Unit 1 at Lower Granite Powerhouse were removed from the rotor and shipped to a repair facility for refurbishment. Upon inspection, it was found that all of the pole bodies exhibited a distinct bow, center to end, on the pole mounting surface. In some cases, the deflection was as much as 0.106 inch. Concerns were raised about how this condition might affect the ability to properly insulate and/or re-seat the poles. This paper presents details of the rotor pole and field winding evaluation, the problems encountered, and the solutions implemented to successfully refurbish the rotor poles and field winding. (author)

  2. A Systematic Review and Meta-Analysis of Ilizarov Methods in the Treatment of Infected Nonunion of Tibia and Femur.

    Directory of Open Access Journals (Sweden)

    Peng Yin

    Full Text Available Infected nonunion of tibia and femur are common in clinical practice, however, the treatment of these diseases has still been a challenge for orthopaedic surgeons. Ilizarov methods can eradicate infection, compensate bone defects and promote the bone union through progressive bone histogenesis. The objective of this systematic review was to review current available studies reporting on Ilizarov methods in the treatment of infected nonunion of tibia and femur, and to perform meta-analysis of bone and functional results and complications to evaluate the efficacy of Ilizarov methods.A comprehensive literature search was performed from the SCI, PubMed, Cochrane Library; and Embase between January 1995 and August 2015. Some major data were statistically analyzed using weighted means based on the sample size in each study by SPSS 13.0, including number of patients, mean age, mean previous surgical procedures, mean bone defects, mean length of follow-up, bone union, complications per patient, external fixation time, and external fixation index(EFI. Bone results (excellent, good, fair and poor rate, functional results (excellent, good, fair and poor rate and complications were analyzed by Stata 9.0.A total of 590 patients from 24 studies were included in this systematic review. The average of bone union rate was 97.26% in all included studies. The poor rate in bone results and functional results was 8% (95%CI, 0.04-0.12; I2 = 44.1%, P = 0.065 and 10% (95%CI, 0.05-0.14; I2 = 34.7%, P = 0.121 in patients with infected nonunion of tibia and femur treated by Ilizarov methods. The rate of refracture, malunion, infectious recurrence, knee stiffness, amputation, limb edema and peroneal nerve palsy was respectively 4%, 7%, 5%, 12%, 4%, 13% and 13%.Our systematic review showed that the patients with infected nonunion of tibia and femur treated by Ilizarov methods had a low rate of poor bone and functional results. Therefore, Ilizarov methods may be a good choice

  3. Fractures of the proximal fifth metatarsal: percutaneous bicortical fixation.

    Science.gov (United States)

    Mahajan, Vivek; Chung, Hyun Wook; Suh, Jin Soo

    2011-06-01

    Displaced intraarticular zone I and displaced zone II fractures of the proximal fifth metatarsal bone are frequently complicated by delayed nonunion due to a vascular watershed. Many complications have been reported with the commonly used intramedullary screw fixation for these fractures. The optimal surgical procedure for these fractures has not been determined. All these observations led us to evaluate the effectiveness of percutaneous bicortical screw fixation for treating these fractures. Twenty-three fractures were operatively treated by bicortical screw fixation. All the fractures were evaluated both clinically and radiologically for the healing. All the patients were followed at 2 or 3 week intervals till fracture union. The patients were followed for an average of 22.5 months. Twenty-three fractures healed uneventfully following bicortical fixation, with a mean healing time of 6.3 weeks (range, 4 to 10 weeks). The average American Orthopaedic Foot & Ankle Society (AOFAS) score was 94 (range, 90 to 99). All the patients reported no pain at rest or during athletic activity. We removed the implant in all cases at a mean of 23.2 weeks (range, 18 to 32 weeks). There was no refracture in any of our cases. The current study shows the effectiveness of bicortical screw fixation for displaced intraarticular zone I fractures and displaced zone II fractures. We recommend it as one of the useful techniques for fixation of displaced zone I and II fractures.

  4. Children's proximal societal conditions

    DEFF Research Database (Denmark)

    Stanek, Anja Hvidtfeldt

    2018-01-01

    that is above or outside the institutional setting or the children’s everyday life, but something that is represented through societal structures and actual persons participating (in political ways) within the institutional settings, in ways that has meaning to children’s possibilities to participate, learn...... and develop. Understanding school or kindergarten as (part of) the children’s proximal societal conditions for development and learning, means for instance that considerations about an inclusive agenda are no longer simply thoughts about the school – for economic reasons – having space for as many pupils...... as possible (schools for all). Such thoughts can be supplemented by reflections about which version of ‘the societal’ we wish to present our children with, and which version of ‘the societal’ we wish to set up as the condition for children’s participation and development. The point is to clarify or sharpen...

  5. Proximity detection system underground

    Energy Technology Data Exchange (ETDEWEB)

    Denis Kent [Mine Site Technologies (Australia)

    2008-04-15

    Mine Site Technologies (MST) with the support ACARP and Xstrata Coal NSW, as well as assistance from Centennial Coal, has developed a Proximity Detection System to proof of concept stage as per plan. The basic aim of the project was to develop a system to reduce the risk of the people coming into contact with vehicles in an uncontrolled manner (i.e. being 'run over'). The potential to extend the developed technology into other areas, such as controls for vehicle-vehicle collisions and restricting access of vehicle or people into certain zones (e.g. non FLP vehicles into Hazardous Zones/ERZ) was also assessed. The project leveraged off MST's existing Intellectual Property and experience gained with our ImPact TRACKER tagging technology, allowing the development to be fast tracked. The basic concept developed uses active RFID Tags worn by miners underground to be detected by vehicle mounted Readers. These Readers in turn provide outputs that can be used to alert a driver (e.g. by light and/or audible alarm) that a person (Tag) approaching within their vicinity. The prototype/test kit developed proved the concept and technology, the four main components being: Active RFID Tags to send out signals for detection by vehicle mounted receivers; Receiver electronics to detect RFID Tags approaching within the vicinity of the unit to create a long range detection system (60 m to 120 m); A transmitting/exciter device to enable inner detection zone (within 5 m to 20 m); and A software/hardware device to process & log incoming Tags reads and create certain outputs. Tests undertaken in the laboratory and at a number of mine sites, confirmed the technology path taken could form the basis of a reliable Proximity Detection/Alert System.

  6. Fatigue failure and cracking in high mast poles.

    Science.gov (United States)

    2012-03-01

    This report presents the findings of a comprehensive research project to investigate the fatigue : cracking and failure of galvanized high mast illumination poles (HMIP). Ultrasonic inspection of : poles throughout the state has revealed the presence...

  7. Extracorporeal shock wave treatment of non- or delayed union of proximal metatarsal fractures.

    Science.gov (United States)

    Alvarez, Richard G; Cincere, Brandon; Channappa, Chandra; Langerman, Richard; Schulte, Robert; Jaakkola, Juha; Melancon, Keith; Shereff, Michael; Cross, G Lee

    2011-08-01

    Nonunion or delayed union of fractures in the proximal aspect of metatarsals 1 to 4 and Zone 2 of the fifth metatarsal were treated by high energy extracorporeal shock wave treatment (ESWT) to study the safety and efficacy of this method of treatment in a FDA study of the Ossatron device. In a prospective single-arm, multi-center study, 34 fractures were treated in 32 patients (two subjects had two independent fractures) with ESWT. All fractures were at least 10 (range, 10 to 833) weeks after injury, with a median of 23 weeks. ESWT application was conducted using a protocol totaling 2,000 shocks for a total energy application of approximately 0.22 to 0.51 mJ/mm2 per treatment. The mean ESWT application time for each of the treatments was 24.6 +/- 16.6 minutes, and anesthesia time averaged 27.1 +/- 10.4 minutes. All subjects were followed for 1 year after treatment at intervals of 12 weeks, 6, 9, and 12 months. The overall success rate at the 12-week visit was 71% with low complications, significant pain improvement as well as improvement on the SF-36. The success/fail criteria was evaluated again at the 6- and 12-month followup, showing treatment success rates of 89% (23/26) and 90% (18/20), respectively. The most common adverse event was swelling in the foot, reported by five subjects (15.6%). High-energy ESWT appears to be effective and safe in patients for treatment of nonunion or a delayed healing of a proximal metatarsal, and in fifth metatarsal fractures in Zone 2.

  8. PROXIMITY MANAGEMENT IN CRISIS CONDITIONS

    Directory of Open Access Journals (Sweden)

    Ion Dorin BUMBENECI

    2010-01-01

    Full Text Available The purpose of this study is to evaluate the level of assimilation for the terms "Proximity Management" and "Proximity Manager", both in the specialized literature and in practice. The study has two parts: the theoretical research of the two terms, and an evaluation of the use of Proximity management in 32 companies in Gorj, Romania. The object of the evaluation resides in 27 companies with less than 50 employees and 5 companies with more than 50 employees.

  9. Theoretical modeling and experimental analyses of laminated wood composite poles

    Science.gov (United States)

    Cheng Piao; Todd F. Shupe; Vijaya Gopu; Chung Y. Hse

    2005-01-01

    Wood laminated composite poles consist of trapezoid-shaped wood strips bonded with synthetic resin. The thick-walled hollow poles had adequate strength and stiffness properties and were a promising substitute for solid wood poles. It was necessary to develop theoretical models to facilitate the manufacture and future installation and maintenance of this novel...

  10. Second-harmonic imaging of poled silica waveguides

    DEFF Research Database (Denmark)

    Arentoft, Jesper; Pedersen, Kjeld; Bozhevolnyi, Sergey I.

    2000-01-01

    Electric-field poled silica-based waveguides are characterized by measurements of second-harmonic generation (SHG) and of the linear electro-optic effect (LEO). A SHG scanning technique allowing for high-resolution imaging of poled devices is demonstrated. Scans along the direction of the poling...

  11. Permanent magnet machine and method with reluctance poles and non-identical PM poles for high density operation

    Science.gov (United States)

    Hsu, John S.

    2010-05-18

    A method and apparatus in which a stator (11) and a rotor (12) define a primary air gap (20) for receiving AC flux and at least one source (23, 40), and preferably two sources (23, 24, 40) of DC excitation are positioned for inducing DC flux at opposite ends of the rotor (12). Portions of PM material (17, 17a) are provided as boundaries separating PM rotor pole portions from each other and from reluctance poles. The PM poles (18) and the reluctance poles (19) can be formed with poles of one polarity having enlarged flux paths in relation to flux paths for pole portions of an opposite polarity, the enlarged flux paths communicating with a core of the rotor (12) so as to increase reluctance torque produced by the electric machine. Reluctance torque is increased by providing asymmetrical pole faces. The DC excitation can also use asymmetric poles and asymmetric excitation sources. Several embodiments are disclosed with additional variations.

  12. Physics on the Z-pole

    International Nuclear Information System (INIS)

    Omori, Tsunehiko; Kurihara, Yoshimasa; Sugimoto, Yasuhiro; Fujii, Yoshiaki; Fujii, Keisuke

    1994-01-01

    JLC will provide a high luminosity of 2.0 x 10 33 cm -2 s -1 on the Z-pole. To realize the Z-pole running we need to add a transport line to bypass unnecessary part of the main linac. With this high luminosity, the third angle of the unitality triangle (sin 2φ 3 ) can be measured in B s (B s ) → pK s channel with 3σ sensitivity in 1 year when sin 2φ 3 = -0.5, Xs = 10, and the branching ratio of the channel is 2 x 10 -5 . Also sin 2 θw can be measured with accuracy of Δsin 2 θw/sin 2 θw = 0.1%. (J.P.N.)

  13. Sun's pole-equator flux differences

    Energy Technology Data Exchange (ETDEWEB)

    Belvedere, G [Istituto di Astronomia dell' Universita di Catania, Italy; Paterno, L [Osservatorio Astrofisico di Catania, Italy

    1977-04-01

    The possibility that large flux differences between the poles and the equator at the bottom of the solar convective zone are compatible with the small differences observed at the surface is studied. The consequences of increasing the depth of the convective zone due to overshooting are explored. A Boussinesq model is used for the convective zone and it is assumed that the interaction of the global convection with rotation is modelled through a convective flux coefficient whose perturbed part is proportional to the local Taylor number. The numerical integration of the equations of motion and energy shows that coexistence between large pole-equator flux differences at the bottom and small ones at the surface is possible if the solar convective zone extends to a depth of 0.4 R(Sun). The angular velocity distribution inside the convective zone is in agreement with the ..cap alpha omega..-dynamo theories of the solar cycle.

  14. Exchange nailing for nonunion of diaphyseal fractures of the tibia: our results and an analysis of the risk factors for failure.

    Science.gov (United States)

    Tsang, S T J; Mills, L A; Frantzias, J; Baren, J P; Keating, J F; Simpson, A H R W

    2016-04-01

    The aim of this study was to identify risk factors for the failure of exchange nailing in nonunion of tibial diaphyseal fractures. A cohort of 102 tibial diaphyseal nonunions in 101 patients with a mean age of 36.9 years (15 to 74) were treated between January 1992 and December 2012 by exchange nailing. Of which 33 (32%) were initially open injuries. The median time from primary fixation to exchange nailing was 6.5 months (interquartile range (IQR) 4.3 to 9.8 months). The main outcome measures were union, number of secondary fixation procedures required to achieve union and time to union. Univariate analysis and multiple regression were used to identify risk factors for failure to achieve union. Multiple causes for the primary nonunion were found for 28 (27%) tibiae, with infection present in 32 (31%). Six patients were lost to follow-up. Further surgical procedures were required in 35 (36%) nonunions. Other fixation modalities were required in five fractures. A single nail exchange procedure achieved union in 60/96 (63%) of all nonunions. Only 11 out of 31 infected nonunions (35.4%) healed after one exchange nail procedure. Up to five repeated exchange nailings, with or without bone grafting, ultimately achieved union in 89 (93%) fractures. The median time to union after exchange nailing was 8.7 months (IQR 5.7 to 14.0 months). Univariate analysis confirmed that an oligotrophic/atrophic pattern of nonunion (p = 0.002), a bone gap of 5 mm or more (p = 0.04) and infection (p exchange nailing Multiple regression analysis found that infection was the strongest predictor of failure (p Exchange nailing is an effective treatment for aseptic tibial diaphyseal nonunion. However, in the presence of severe infection with a highly resistant organism, or extensive sclerosis of the bone, other fixation modalities, such as Ilizarov treatment, should be considered. Exchange nailing is an effective treatment for aseptic tibial diaphyseal nonunion. ©2016 The British Editorial

  15. The South Pole and the Ross Sea

    Science.gov (United States)

    2002-01-01

    This image shows a rare clear view of the South Pole (lower right) and the Ross Sea, Antarctica. The Sea-viewing Wide Field-of-view Sensor (SeaWiFS) acquired the scene on December 26, 2001. The geographic South Pole is located in the center of Antarctica, at an altitude of 2,900 meters (9,300 feet). It rests on a continent-wide ice sheet that is 2,870 m thick, with the underlying bedrock only 30 m (98 feet) above sea level. The ice underlying the South Pole is as much as 140,000 years old, and is currently accumulating at about 82 cm (32 inches) per year. Roughly 2,500 km (1,550 miles) away is the green water of the Ross Sea, which indicates the presence of large numbers of phytoplankton. This is a highly productive part of the world's oceans. Also note the ice gathered around McMurdo Sound, seen toward the lefthand shoreline of the Ross Sea, at the edge of the Ross Ice Shelf. According to National Science Foundation researchers, this ice is making it difficult for penguins to reach their food supply. Separating the continental Antarctic ice sheet from the Ross Sea are the Queen Maud Mountains and the Ross Ice Shelf. Image courtesy the SeaWiFS Project, NASA/Goddard Space Flight Center, and ORBIMAGE

  16. Current superimposition variable flux reluctance motor with 8 salient poles

    Science.gov (United States)

    Takahara, Kazuaki; Hirata, Katsuhiro; Niguchi, Noboru; Kohara, Akira

    2017-12-01

    We propose a current superimposition variable flux reluctance motor for a traction motor of electric vehicles and hybrid electric vehicles, which consists of 10 salient poles in the rotor and 12 slots in the stator. However, iron losses of this motor in high rotation speed ranges is large because the number of salient poles is large. In this paper, we propose a current superimposition variable flux reluctance motor that consists of 8 salient poles and 12 slots. The characteristics of the 10-pole-12-slot and 8-pole-12-slot current superimposition variable flux reluctance motors are compared using finite element analysis under vector control.

  17. Current superimposition variable flux reluctance motor with 8 salient poles

    Directory of Open Access Journals (Sweden)

    Takahara Kazuaki

    2017-12-01

    Full Text Available We propose a current superimposition variable flux reluctance motor for a traction motor of electric vehicles and hybrid electric vehicles, which consists of 10 salient poles in the rotor and 12 slots in the stator. However, iron losses of this motor in high rotation speed ranges is large because the number of salient poles is large. In this paper, we propose a current superimposition variable flux reluctance motor that consists of 8 salient poles and 12 slots. The characteristics of the 10-pole-12-slot and 8-pole-12-slot current superimposition variable flux reluctance motors are compared using finite element analysis under vector control.

  18. Regulation of proximal tubule vacuolar H+-ATPase by PKA and AMP-activated protein kinase

    Science.gov (United States)

    Al-bataineh, Mohammad M.; Gong, Fan; Marciszyn, Allison L.; Myerburg, Michael M.

    2014-01-01

    The vacuolar H+-ATPase (V-ATPase) mediates ATP-driven H+ transport across membranes. This pump is present at the apical membrane of kidney proximal tubule cells and intercalated cells. Defects in the V-ATPase and in proximal tubule function can cause renal tubular acidosis. We examined the role of protein kinase A (PKA) and AMP-activated protein kinase (AMPK) in the regulation of the V-ATPase in the proximal tubule as these two kinases coregulate the V-ATPase in the collecting duct. As the proximal tubule V-ATPases have different subunit compositions from other nephron segments, we postulated that V-ATPase regulation in the proximal tubule could differ from other kidney tubule segments. Immunofluorescence labeling of rat ex vivo kidney slices revealed that the V-ATPase was present in the proximal tubule both at the apical pole, colocalizing with the brush-border marker wheat germ agglutinin, and in the cytosol when slices were incubated in buffer alone. When slices were incubated with a cAMP analog and a phosphodiesterase inhibitor, the V-ATPase accumulated at the apical pole of S3 segment cells. These PKA activators also increased V-ATPase apical membrane expression as well as the rate of V-ATPase-dependent extracellular acidification in S3 cell monolayers relative to untreated cells. However, the AMPK activator AICAR decreased PKA-induced V-ATPase apical accumulation in proximal tubules of kidney slices and decreased V-ATPase activity in S3 cell monolayers. Our results suggest that in proximal tubule the V-ATPase subcellular localization and activity are acutely coregulated via PKA downstream of hormonal signals and via AMPK downstream of metabolic stress. PMID:24553431

  19. Computed tomographic evaluation of the proximal femur: A predictive classification in displaced femoral neck fracture management

    Directory of Open Access Journals (Sweden)

    Narender Kumar Magu

    2014-01-01

    Full Text Available Background: Femoral neck fracture is truly an enigma due to the high incidence of avascular necrosis and nonunion. Different methods have been described to determine the size of the femoral head fragment, as a small head has been said to be associated with poor outcome and nonunion due to inadequate implant purchase in the proximal fragment. These methods were two dimensional and were affected by radiography techniques, therefore did not determine true head size. Computed tomography (CT is an important option to measure true head size as images can be obtained in three dimensions. Henceforth, we subjected patients to CT scan of hip in cases with displaced fracture neck of femur. The study aims to define the term "small head or inadequate size femoral head" objectively for its prognostic significance. Materials and Methods: 70 cases of displaced femoral neck fractures underwent CT scan preoperatively for proximal femoral geometric measurements of both hips. Dual energy X-ray absorptiometry scan was done in all cases. Patients were treated with either intertrochanteric osteotomy or lag screw osteosynthesis based on the size of the head fragment on plain radiographs. Results: The average femoral head fragment volume was 57 cu cm (range 28.3-84.91 cu cm; standard deviation 14 cu cm. Proximal fragment volume of >43 cu cm was termed adequate size (type I and of ≤43 cu cm as small femoral head (type II. Fractures which united (n = 54 had a relatively large average head size (59 cu cm when compared to fractures that did not (n = 16, which had a small average head size (49 cu cm and this difference was statistically significant. In type I fractures union rate was comparable in both osteotomy and lag screw groups (P > 0.05. Lag screw fixation failed invariably, while osteotomy showed good results in type II fractures (P < 0.05. Conclusion: Computed tomography scan of the proximal femur is advisable for measuring true size of head fragment. An objective

  20. Jupiter's interior and deep atmosphere: The initial pole-to-pole passes with the Juno spacecraft

    DEFF Research Database (Denmark)

    Bolton, S. J.; Adriani, Alberto; Adumitroaie, V.

    2017-01-01

    On 27 August 2016, the Juno spacecraft acquired science observations of Jupiter, passing less than 5000 kilometers above the equatorial cloud tops. Images of Jupiter's poles show a chaotic scene, unlike Saturn's poles. Microwave sounding reveals weather features at pressures deeper than 100 bars,...... of magnitude more precise. This has implications for the distribution of heavy elements in the interior, including the existence and mass of Jupiter's core. The observed magnetic field exhibits smaller spatial variations than expected, indicative of a rich harmonic content....

  1. Proximal Opening Wedge Osteotomy Provides Satisfactory Midterm Results With a Low Complication Rate.

    Science.gov (United States)

    Oravakangas, Rami; Leppilahti, Juhana; Laine, Vesa; Niinimäki, Tuukka

    2016-01-01

    Hallux valgus is one of the most common foot deformities. Proximal opening wedge osteotomy is used for the treatment of moderate and severe hallux valgus with metatarsus primus varus. However, hypermobility of the first tarsometatarsal joint can compromise the results of the operation, and a paucity of midterm results are available regarding proximal open wedge osteotomy surgery. The aim of the present study was to assess the midterm results of proximal open wedge osteotomy in a consecutive series of patients with severe hallux valgus. Thirty-one consecutive adult patients (35 feet) with severe hallux valgus underwent proximal open wedge osteotomy. Twenty patients (35.5%) and 23 feet (34.3%) were available for the final follow-up examination. The mean follow-up duration was 5.8 (range 4.6 to 7.0) years. The radiologic measurements and American Orthopaedic Foot and Ankle Society hallux-metatarsophalangeal-interphalangeal scores were recorded pre- and postoperatively, and subjective questionnaires were completed and foot scan analyses performed at the end of the follow-up period. The mean hallux valgus angle decreased from 38° to 23°, and the mean intermetatarsal angle correction decreased from 17° to 10°. The mean improvement in the American Orthopaedic Foot and Ankle Society hallux metatarsophalangeal-interphalangeal score increased from 52 to 84. Two feet (5.7%) required repeat surgery because of recurrent hallux valgus. No nonunions were identified. Proximal open wedge osteotomy provided satisfactory midterm results in the treatment of severe hallux valgus, with a low complication rate. The potential instability of the first tarsometatarsal joint does not seem to jeopardize the midterm results of the operation. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  2. ProxImaL: efficient image optimization using proximal algorithms

    KAUST Repository

    Heide, Felix; Diamond, Steven; Nieß ner, Matthias; Ragan-Kelley, Jonathan; Heidrich, Wolfgang; Wetzstein, Gordon

    2016-01-01

    domain-specific language and compiler for image optimization problems that makes it easy to experiment with different problem formulations and algorithm choices. The language uses proximal operators as the fundamental building blocks of a variety

  3. Post-traumatic nonunion of the clavicle in a 4-year-old boy and the importance of vitamin D level testing.

    Science.gov (United States)

    Duplantier, Neil L; Waldron, Sean

    2016-01-01

    Clavicle fractures in children are common and usually go on to achieve solid union with closed treatment. A limited number of pediatric clavicle fracture nonunion cases have been reported in the literature, none of which were directly associated with hypovitaminosis D. We report the youngest case to our knowledge in a 4-year-old vitamin D-deficient male with a 6-month-old right midshaft clavicle fracture nonunion that was treated successfully with vitamin D supplementation, followed by open reduction and internal fixation with autologus iliac crest bone grafting.

  4. Tent-Poles of the Bestseller

    DEFF Research Database (Denmark)

    Jensen, Thessa; Vistisen, Peter

    2013-01-01

    This article proposes a framework for understanding and analysing how the passive audience of a media event turns into active stakeholders. The starting point is the cross-media content quadrant (Jensen and Vistisen, 2012), which shows how the producer’s control is distributed on social media...... platforms, while storytelling evolves around a tent-pole, for example, a bestseller or blockbuster. To further explain how the audience engages, a three-step rhetoric model largely based on Bitzer (1998) and Tolkien (1971) is developed and explained....

  5. Infrared solar physics from the South Pole

    Science.gov (United States)

    Deming, Drake

    1989-01-01

    Infrared (IR) observations of the sun could greatly benefit from the quality of the South Pole as an IR site, and the potential for multi-day sequences of uninterrupted observations. A nearly continuous picture of the evolution of the magnetic field in solar active regions could be obtained using vector magnetographs, especially vector magnetographs which incorporate IR array detectors. Observations of the sun over a range of wavelengths in the IR continuum could also be used to study the vertical propagation characteristics of the solar p-mode oscillations.

  6. Complex conjugate poles and parton distributions

    International Nuclear Information System (INIS)

    Tiburzi, B.C.; Detmold, W.; Miller, G.A.

    2003-01-01

    We calculate parton and generalized parton distributions in Minkowski space using a scalar propagator with a pair of complex conjugate poles. Correct spectral and support properties are obtained only after careful analytic continuation from Euclidean space. Alternately the quark distribution function can be calculated from modified cutting rules, which put the intermediate state on its complex mass shells. Distribution functions agree with those resulting from the model's Euclidean space double distribution which we calculate via nondiagonal matrix elements of twist-two operators. Thus one can use a wide class of analytic parametrizations of the quark propagator to connect Euclidean space Green functions to light-cone dominated amplitudes

  7. A proximal point algorithm with generalized proximal distances to BEPs

    OpenAIRE

    Bento, G. C.; Neto, J. X. Cruz; Lopes, J. O.; Soares Jr, P. A.; Soubeyran, A.

    2014-01-01

    We consider a bilevel problem involving two monotone equilibrium bifunctions and we show that this problem can be solved by a proximal point method with generalized proximal distances. We propose a framework for the convergence analysis of the sequences generated by the algorithm. This class of problems is very interesting because it covers mathematical programs and optimization problems under equilibrium constraints. As an application, we consider the problem of the stability and change dyna...

  8. Fractures of the proximal humerus

    DEFF Research Database (Denmark)

    Brorson, Stig

    2013-01-01

    Fractures of the proximal humerus have been diagnosed and managed since the earliest known surgical texts. For more than four millennia the preferred treatment was forceful traction, closed reduction, and immobilization with linen soaked in combinations of oil, honey, alum, wine, or cerate......, classification of proximal humeral fractures remains a challenge for the conduct, reporting, and interpretation of clinical trials. The evidence for the benefits of surgery in complex fractures of the proximal humerus is weak. In three systematic reviews I studied the outcome after locking plate osteosynthesis...

  9. Neglected nonunion of phalangeal neck fractures of the thumb in children: the outcome of delayed bone grafting in adulthood.

    Science.gov (United States)

    Al-Qattan, Mohammad M

    2012-03-01

    Over a 12-year period, the author treated a total of 5 adults (mean age, 23 years) with neglected nonunion of phalangeal neck fractures of the thumb that were sustained in early childhood. Cosmetically, the affected thumb was shorter and smaller than the contralateral thumb. The thumb tip was flail and thumb pinch was weak. X-rays showed a nonunited phalangeal neck fracture with no radiologic evidence of avascular necrosis of the phalangeal head. All patients underwent iliac crest bone grafting. Bone union was obtained in all patients. At final follow-up (mean, 9 months), all patients were satisfied with the cosmetic appearance of the thumb. The thumb length increased by an average of 6 mm (range, 5-8 mm). Pinch improved in the range of 69% to 87% of the power of the contralateral thumb. However, there was restricted range of motion of the interphalangeal joint (mean range of motion of 10 degree only). It was concluded that delayed bone grafting of neglected nonunions of pediatric phalangeal neck fractures of the thumb is a worthwhile procedure and has a high satisfaction rate.

  10. Reduced rates of non-union with modified periacetabular osteotomy using peracetic-acid sterilized cancellous allografts.

    Science.gov (United States)

    Wassilew, Georgi I; Janz, Viktor; Renner, Lisa; Perka, Carsten; Pruss, Axel

    2016-12-01

    The objective of the present study was to analyze the clinical and radiological results of periacetabular osteotomies (PAO) using Kirschner wire fixation and an allogeneic cancellous bone graft. This retrospective cohort study included 73 patients (85 PAOs). The allografts were processed from distal femur of cadaveric donors, defatted, sterilized with a peracetic-acid ethanol solution and freeze-dried. The clinical outcome, as measured by the Harris Hip Scores (HHS), the complication rate and the acetabular correction, as measured by radiological parameters, were compared. The postoperative femoral head coverage and HSS were significantly improved. Major complications occurred in five cases (6 %), but in no case did we observe a non-union or a graft-associated adverse effect. Fixation of the acetabular fragment with Kirschner wires in combination with an allogeneic cancellous bone graft is a safe method, with a low complication rate, no loss of correction and can prevent the occurrence of non-union with a high degree of probability.

  11. Design of a portable CAT scanner for utility pole inspection

    International Nuclear Information System (INIS)

    Miller, W.H.

    1986-01-01

    Work is under way at the University of Missouri, Columbia (UMC) to design, build, and test a portable computerized axial tomography (CAT) device for the nondestructive, field imaging of wooden utility poles. CAT is a well-established medical technology that has recently been applied to a number of industrial applications. Wooden utility poles are prone to rot and decay at ground level; current techniques to assess this loss of strength are relatively primitive, i.e., tapping the pole (hitting the pole with a hammer) or boring into the pole for samples and then testing inside the bore hole with an electrical pulse device. The accuracy in identifying poles needing replacement using these techniques is ∼ 70%. Since the cost of replacing a pole ranges from hundreds to thousands of dollars, an accurate, nondestructive method is needed. CAT can accurately image a wooden utility pole (since the size, density, and atomic elements of a pole are similar to the human head to torso), as was confirmed by imaging poles using the UMC nuclear engineering EMI-1010 medical scanner. Detailed images have been produced showing the ring structure of the wood and voids due to rot or decay. Images approaching this quality have also been produced on living trees using semiportable systems by other researchers

  12. Triple management of cubitus valgus deformity complicating neglected nonunion of fractures of lateral humeral condyle in children: a case series.

    Science.gov (United States)

    Abed, Yasser; Nour, Khaled; Kandil, Yasser Roshdy; El-Negery, Abed

    2018-02-01

    Long standing nonunion of the lateral humeral condyle (LHC) usually results in elbow pain and instability with progressive cubitus valgus and tardy ulnar neuritis. Surgical treatment of long standing nonunion is still a controversial issue due to the reported complications, such as stiffness, loss of elbow motion, and avascular necrosis of the LHC fragment. In this study, we reported the outcomes of treatment of cubitus valgus deformity in long standing nonunion of the LHC in children treated with combined triple management (fixation of the nonunion site, dome corrective osteotomy, and anterior transposition of ulnar nerve) through a modified para-triceptal approach. We evaluated ten patients with cubitus valgus deformity more than 20 degrees after neglected nonunion of the lateral humeral condyle more than 24 months. Only childern with post-operative follow up more than 24 months were included in this study. All patients were evaluated clinically, radio logically, and by pre- and post-operative functional evaluation using Mayo elbow performance score. For evaluation of ulnar nerve affection, the Akahori's system was used. There were six females and four males with the average age of 7.7 years at operation. The left elbow was affected in six patients and the right elbow was affected in four patients. The average time between fracture of the LHC and operation was 40.3 months with average post-operative follow up of 44.3 months. The average carrying angle of the healthy side was 5.5 degrees and pre-operative carrying angle of the affected side was 33.5 degrees. The average post-operative carrying angle of the affected side was 6.1 degrees. The improvement of the carrying angle at the last follow up was found statistically significant (p  0.05). The mean pre-operative Mayo elbow performance score was poor 55 ± 9.7, four patients had fair score, and six had poor score. The mean post-operative Mayo elbow performance score was excellent 92.5 ± 10, six

  13. The Pole Orientation, Pole Precession, and Moment of Inertia Factor of Saturn

    Science.gov (United States)

    Jacobson, R. A.; French, R. G.; Nicholson, P. D.; Hedman, M.; Colwell, J. E.; Marouf, E.; Rappaport, N.; McGhee, C.; Sepersky, T.; Lonergan, K.

    2011-01-01

    This paper discusses our determination of the Saturn's pole orientation and precession using a combination of Earthbased and spacecraft based observational data. From our model of the polar motion and the observed precession rate we obtain a value for Saturn's polar moment of inertia

  14. Minimally Invasive Treatment of Displaced Proximal Humeral Fractures in Patients Older Than 70 Years Using the Humerusblock

    Directory of Open Access Journals (Sweden)

    Robert Bogner

    2016-01-01

    Full Text Available Background. Surgical treatment of proximal humeral fractures (PHF in osteoporotic bone of elderly patients is challenging. The aim of this retrospective study was to evaluate the clinical and radiological outcome after percutaneous reduction and internal fixation of osteoporotic PHF in geriatric patients using the semirigid Humerusblock device. Methods. In the study period from 2005 to 2010, 129 patients older than 70 years were enrolled in the study. After a mean follow-up of 23 months, a physical examination, using the Constant-Murley score and the VAS pain scale, was performed. Furthermore radiographs were taken to detect signs of malunion, nonunion, and avascular necrosis. Results. The recorded Constant-Murley score was 67.7 points (87.7% of the noninjured arm for two-part fractures, 67.9 points (90.8% for three-part fractures, and 43.0 points (56.7% for four-part fractures. In ten shoulders (7.8% loss of reduction and in four shoulders (3.1% nonunion were the reason for revision surgery. Avascular humeral head necrosis developed in eight patients (6.2%. Conclusions. In two- and three-part fractures postoperative results are promising. Sufficient ability for the activities of daily living was achieved. In four-part fractures the functional results were less satisfying regarding function and pain with a high postoperative complication rate. In those patients other treatment strategies should be considered. Study design. Therapeutic retrospective case series (evidence-based medicine (EBM level IV.

  15. Should the tip-apex distance (TAD) rule be modified for the proximal femoral nail antirotation (PFNA)? A retrospective study.

    Science.gov (United States)

    Nikoloski, Andrej N; Osbrough, Anthony L; Yates, Piers J

    2013-10-17

    Unstable proximal femoral fractures are common and challenging for the orthopaedic surgeon. Often, these are treated with intramedullary nails. The most common mode of failure of any device to treat these fractures is cut-out. The Synthes proximal femoral nail antirotation (PFNA) is unique because it is the only proximal femoral intramedullary nail which employs a helical blade in lieu of a lag screw. The optimal tip-apex distance is 25 mm or less for a dynamic hip screw. The optimal blade tip placement is not known for the PFNA. The aim of this study is to determine if the traditional tip-apex distance rule (TAD) less than 20 mm. There was no cut-out in cases where the TAD was from 20-30 mm. There were three implant-related failures (nail fracture, missed nail and loose locking screw), four implant-related femoral fractures, two non-unions, two delayed unions and one loss of reduction. The PFNA is a suitable fixation device for the treatment of unstable proximal femoral fractures. There were still a relatively large number of cut-outs, and the tip-apex distance in the failures showed a bimodal distribution, not like previously demonstrated with dynamic hip screw. We propose that the helical blade behaves differently to a screw, and placement too close to the subchondral bone may lead to penetration through the head.

  16. Multiple pole in the electron--hydrogen-atom scattering amplitude

    International Nuclear Information System (INIS)

    Amusia, M.Y.; Kuchiev, M.Y.

    1982-01-01

    It is demonstrated that the amplitude for electron--hydrogen-atom forward scattering has the third-order pole at the point E = -13.6 eV, E being the energy of the incident electron. The coefficients which characterize the pole are calculated exactly. The invalidity of the Born approximation is proved. The contribution of the pole singularity to the dispersion relation for the scattering amplitude is discussed

  17. Determination of the crystallite orientation distribution from direct pole figures

    International Nuclear Information System (INIS)

    Araujo Gomes, P.A.M. de.

    1977-01-01

    A method is described which allows to calculate the crystallite orientation distribution in polycrystalline material, from direct pole figures data of its crystallographic planes (Roe's Method). The programme was applied to (1010), (0002), (1011) and (1120) complete pole figures data for a commercial, thin sheet Zircaloy-4 tubing specimen. A semi-automatic Rigaku-Denki texture goniometer, which scans the reciprocal lattice sphere pointwise outputting the data in a punched tape, was used to obtain the pole figures. This is consistent with the results obtained through direct conclusion from the pole figures. (author)

  18. Thermal poling of multi-wire array optical fiber

    DEFF Research Database (Denmark)

    Huang, Lin; An, Honglin; Hayashi, Juliano G.

    2018-01-01

    We demonstrate in this paper thermal poling of multi-wire array fibers, which extends poling of fibers with two anodes to similar to 50 and similar to 500 wire array anodes. The second harmonic microscopy observations show that second order nonlinearity (SON) layers are developed surrounding all...... the rings of wires in the similar to 50 anode array fiber with poling of 1.8kV, 250 degrees C and 30min duration, and the outer rings of the similar to 500 anode array fiber at lower poling temperature. Our simulations based on a two-dimensional charge dynamics model confirm this can be explained...

  19. POLE mutations in families predisposed to cutaneous melanoma

    DEFF Research Database (Denmark)

    Aoude, Lauren G; Heitzer, Ellen; Johansson, Peter

    2015-01-01

    Germline mutations in the exonuclease domain of POLE have been shown to predispose to colorectal cancers and adenomas. POLE is an enzyme involved in DNA repair and chromosomal DNA replication. In order to assess whether such mutations might also predispose to cutaneous melanoma, we interrogated...... variants in the exonuclease domain of POLE. Although this frequency is not significantly higher than that in unselected Caucasian controls, we observed multiple cancer types in the melanoma families, suggesting that some germline POLE mutations may predispose to a broad spectrum of cancers, including...

  20. Generalized pole inflation: Hilltop, natural, and chaotic inflationary attractors

    Energy Technology Data Exchange (ETDEWEB)

    Terada, Takahiro, E-mail: takahiro.terada@apctp.org [Department of Physics, The University of Tokyo, Tokyo 113-0033 (Japan); Asia Pacific Center for Theoretical Physics, Pohang 37673 (Korea, Republic of)

    2016-09-10

    A reformulation of inflationary model analyses appeared recently, in which inflationary observables are determined by the structure of a pole in the inflaton kinetic term rather than the shape of the inflaton potential. We comprehensively study this framework with an arbitrary order of the pole taking into account possible additional poles in the kinetic term or in the potential. Depending on the setup, the canonical potential becomes the form of hilltop or plateau models, variants of natural inflation, power-law inflation, or monomial/polynomial chaotic inflation. We demonstrate attractor behaviors of these models and compute corrections from the additional poles to the inflationary observables.

  1. South Pole Region of the Moon as Seen by Clementine

    Science.gov (United States)

    1994-01-01

    Lunar mosaic of 1500 Clementine images of the south polar region of the moon. The projection is orthographic, centered on the south pole. The Schrodinger Basin (320 km in diameter) is located in the lower right of the mosaic. Amundsen-Ganswindt is the more subdued circular basin between Schrodinger and the pole. The polar regions of the moon are of special interest because of the postulated occurrence of ice in permanently shadowed areas. The south pole is of greater interest because the area that remains in shadow is much larger than that at the north pole.

  2. Genetic predisposition to fracture non-union: a case control study of a preliminary single nucleotide polymorphisms analysis of the BMP pathway

    Directory of Open Access Journals (Sweden)

    Giannoudis Peter V

    2011-02-01

    Full Text Available Abstract Background Despite the known multi-factorial nature of atrophic fracture non-unions, a possible genetic predisposition for the development of this complication after long bone fractures remains unknown. This pilot study aimed to address this issue by performing a preliminary SNP analysis of specific genes known to regulate fracture healing. Methods A total of fifteen SNPs within four genes of the Bone Morphogenetic Protein (BMP pathway (BMP-2, BMP-7, NOGGIN and SMAD6 were examined, in 109 randomly selected patients with long bone fractures as a result of motor vehicle accident, fall or direct blow. There were sixty-two patients with atrophic non-union and forty-seven patients (54 fractures with uneventful fracture union. Overall SNPs frequencies were computed with respect to patient's age, gender, smoking habits, fracture-associated parameters and the use of nonsteroidal anti-inflammatory drugs (NSAIDs, and tested for their association to the impaired bone healing process, using binary logistic regression (STATA 11.1; StataCorp, Texas USA. Results Statistical analysis revealed age to be an important covariate in the development of atrophic non-union (p = 0.01, OR 1.05 [per year], and two specific genotypes (G/G genotype of the rs1372857 SNP, located on NOGGIN and T/T genotype of the rs2053423 SNP, located on SMAD6 to be associated with a greater risk of fracture non-union (p = 0.02, OR 4.56 and p = 0.04, OR 10.27, respectively, after adjustment for age. Conclusions This is the first clinical study to investigate the potential existence of genetic susceptibility to fracture non-union. Even though no concrete conclusions can be obtained from this pilot study, our results indicate the existence of a potential genetically predetermined impairment within the BMP signalling cascade, initiated after a fracture and when combined with other risk factors could synergistically increase the susceptibility of a patient to develop non-union. Further

  3. Pole inflation in Jordan frame supergravity

    Energy Technology Data Exchange (ETDEWEB)

    Saikawa, Ken' ichi [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Yamaguchi, Masahide [Tokyo Institute of Technology, Ookayama (Japan). Dept. of Physics; Yamashita, Yasuho [Kyoto Univ. (Japan). Yukawa Inst. for Theoretical Physics; Yoshida, Daisuke [Montreal Univ., QC (Canada). Dept. of Physics

    2017-09-15

    We investigate inflation models in Jordan frame supergravity, in which an inflaton non-minimally couples to the scalar curvature. By imposing the condition that an inflaton would have the canonical kinetic term in the Jordan frame, we construct inflation models with asymptotically flat potential through pole inflation technique and discuss their relation to the models based on Einstein frame supergravity. We also show that the model proposed by Ferrara et al. has special position and the relation between the Kaehler potential and the frame function is uniquely determined by requiring that scalars take the canonical kinetic terms in the Jordan frame and that a frame function consists only of a holomorphic term (and its anti-holomorphic counterpart) for symmetry breaking terms. Our case corresponds to relaxing the latter condition.

  4. Performance of new generation pole light

    International Nuclear Information System (INIS)

    Foo, K C; Karunanithi, S; Thio, G

    2013-01-01

    This paper describes the design and implementation of a standalone photovoltaic power supply which caters for garden lighting scheme. New Generation Pole Light (NGPL) consists of three parts which are light dependent resistor (LDR) and pyroelectric infrared (PIR) sensors, microcontroller and light emitting diode (LED) and finally, solar charging system. During the night, LED is switched on with two operating modes which are ultra-bright lighting for a predetermine period (when human presence is detected) and dim lighting. Meanwhile, LED is switched off at day time and solar charging system will recover the capacity of discharged battery. NGPL provides portable, sustainable, environmental friendly and requires minimal maintenance for outdoor lighting scheme for both urban and rural areas.

  5. Two-pole microring weight banks.

    Science.gov (United States)

    Tait, Alexander N; Wu, Allie X; Ferreira de Lima, Thomas; Nahmias, Mitchell A; Shastri, Bhavin J; Prucnal, Paul R

    2018-05-15

    Weighted addition is an elemental multi-input to single-output operation that can be implemented with high-performance photonic devices. Microring (MRR) weight banks bring programmable weighted addition to silicon photonics. Prior work showed that their channel limits are affected by coherent inter-channel effects that occur uniquely in weight banks. We fabricate two-pole designs that exploit this inter-channel interference in a way that is robust to dynamic tuning and fabrication variation. Scaling analysis predicts a channel count improvement of 3.4-fold, which is substantially greater than predicted by incoherent analysis used in conventional MRR devices. Advances in weight bank design expand the potential of reconfigurable analog photonic networks and multivariate microwave photonics.

  6. Retratos da metrópole parisiense

    OpenAIRE

    Saint-Julien, Thérèse; Goix, Renaud Le

    2009-01-01

    « La métropole parisienne, centralité, inégalité, proximité » propõe uma leitura e uma interpretação das tendências do território da Île de France (a região que inclui Paris e sete outros départements), ou seja, uma grande metrópole mundial de cerca de 11,3 milhões de habitantes em 2004, ligada às redes da globalização e da metropolização. O livro esboça os traços principais de suas estruturas territoriais emergentes, sublinha os desafios, o alcance dos mesmos e as contradições. Sem pretensão...

  7. Retratos da metrópole parisiense

    Directory of Open Access Journals (Sweden)

    Thérèse Saint-Julien

    2009-07-01

    Full Text Available « La métropole parisienne, centralité, inégalité, proximité » propõe uma leitura e uma interpretação das tendências do território da Île de France (a região que inclui Paris e sete outros départements, ou seja, uma grande metrópole mundial de cerca de 11,3 milhões de habitantes em 2004, ligada às redes da globalização e da metropolização. O livro esboça os traços principais de suas estruturas territoriais emergentes, sublinha os desafios, o alcance dos mesmos e as contradições. Sem pretensão...

  8. Pole inflation in Jordan frame supergravity

    International Nuclear Information System (INIS)

    Saikawa, Ken'ichi; Yamaguchi, Masahide; Yamashita, Yasuho; Yoshida, Daisuke

    2017-09-01

    We investigate inflation models in Jordan frame supergravity, in which an inflaton non-minimally couples to the scalar curvature. By imposing the condition that an inflaton would have the canonical kinetic term in the Jordan frame, we construct inflation models with asymptotically flat potential through pole inflation technique and discuss their relation to the models based on Einstein frame supergravity. We also show that the model proposed by Ferrara et al. has special position and the relation between the Kaehler potential and the frame function is uniquely determined by requiring that scalars take the canonical kinetic terms in the Jordan frame and that a frame function consists only of a holomorphic term (and its anti-holomorphic counterpart) for symmetry breaking terms. Our case corresponds to relaxing the latter condition.

  9. Preliminary study on leadership proximity

    Directory of Open Access Journals (Sweden)

    Ghinea Valentina Mihaela

    2017-07-01

    Full Text Available In general, it is agreed that effective leadership requires a certain degree of proximity, either physical or mental, which enables leaders to maintain control over their followers and communicate their vision. Although we agree with the leadership proximity principles which states that leaders are able to efficiently serve only those people with whom they interact frequently, in this article we focus instead on the disadvantages of being too close and the way in which close proximity can actually hurt the effectiveness of leadership. The main effects that we discuss regard the way in which proximity and familiarity allow followers to see the weaknesses and faults of the leader much more easily and thus diminish the leader’s heroic aura, and the emotional bias that results from a leader being too familiar with his followers which will impede the process of rational decision making. As a result, we argue that there exists a functional proximity which allows the leader the necessary space in which to perform effective identity work and to hide the backstage aspects of leadership, while also allowing him an emotional buffer zone which will enable him to maintain the ability to see clearly and make rational decisions.

  10. What is the Effect of 90-Degree Double-Plate Fixation with Grafting on Healing of Humeral Shaft Non-unions

    Directory of Open Access Journals (Sweden)

    Mutlu Çobanoğlu

    2016-08-01

    Full Text Available Objective: Our aim was to investigate the clinical and radiological outcomes of double-plate fixation with grafting in the treatment of non-union of humeral shaft fractures. Materials and Methods: We performed a retrospective chart review of patients operated between 2006 and 2012 due to humeral shaft non-union. Patients undergoing surgery with double-plate fixation were included and those treated with external fixator, single plate, intramedullary nails and patients with pathological fractures and infected non-unions were excluded. Surgical intervention via anterolateral or posterior approach included radial nerve identification, decortication and reestablishment of medullary canal followed by compression plating with double-plate fixation and frequent application of autogenous grafts or allografts. Main outcome measures were success rate of non-union repair, rate of re-intervention and complications, range of motion, assessment of pain Visual analogue scale (VAS and function Disabilities of the arm, shoulder and hand (DASH and overall outcome Stewart-Hundley classification. Results: Ten patients were treated with double-plate fixation. The study group included six females and four males aged 36 to 70 years. Union was achieved within 4.5 and 8 months in all cases. The mean preoperative VAS score of 6.1 decreased to 2, postoperatively, with an associated decrease in the mean DASH score from 74.1 to 23.4. Excellent or good results were obtained in nine cases. There was no incidence of radial nerve palsy or infection. Conclusion: Our study provides level 4 evidence of the effectiveness of treating non-union fractures of the humeral shaft with double-plate fixation and grafting in providing good-to-excellent functional results and high union rate without any significant complication.

  11. Measurement and calculation of cosmic radiation exposure during a pole-to-pole flight sequence

    International Nuclear Information System (INIS)

    Taylor, Graeme C.; Ojjeh, Captain Aziz

    2010-01-01

    Cosmic ray dosimetry measurements were carried out on board a Global Express business jet operated by TAG Aviation (UK) during a pole-to-pole flight sequence that took place in November 2008. One Hawk TEPC and two EPDN2s were flown, and the TEPC measurements compared to calculated values from the route dose codes AVIDOS, CARI 6M, EPCARD versions 3.2 and 3.34, QARM and SIEVERT (online version). The largest difference between measured and calculated doses for the total flight sequence was found to be 13%. Agreement between the readings of the TEPC and the EPDN2s (once a calibration factor from the CERN High Energy Reference Field had been applied) was reasonably good given the relatively large uncertainties associated with the EPDN2 measurements.

  12. Defect nonunion of a metatarsal bone fracture in a cow: successful management with bone plating and autogenous cancellous bone graft.

    Science.gov (United States)

    Raghunath, M; Singh, N; Singh, T; Gopinathan, A; Mohindroo, J; Atri, K

    2013-01-01

    A two-and-half-year-old cow was presented with a defect nonunion of the right metatarsal III/IV bone following a severely comminuted open fracture two months previously. The animal underwent open fixation using a 4.5 mm, broad, 10-hole, dynamic compression plate and autogenous cancellous bone graft collected from the contralateral iliac shaft. The animal started partial weight bearing after the third postoperative day and resumed complete weight bearing after the 10th day. Fracture healing was complete and the implants were removed after the 120th postoperative day. Stable fixation by means of a bone plate in conjunction with a cancellous bone graft facilitated complete healing and restoration of the bone column of the defect and the metatarsal fracture. The animal made a complete recovery.

  13. Fracture of Fully-coated Femoral Stem after Primary Total Hip Arthroplasty for Nonunion of Intertrochanteric Fracture: A Case Report.

    Science.gov (United States)

    Chun, Young Soo; Juh, Hyung Suk; Cho, Yoon Je; Rhyu, Kee Hyung

    2015-09-01

    Femoral stem fracture is an uncommon reason for the failure of total hip arthroplasty, with only 16 cases of fully coated stem fractures reported to date. Here we report a case in which a fully coated primary femoral stem fracture occurred after conversion to total hip arthroplasty for the non-union of an intertrochanteric fracture of the femur. Metallurgic evaluation of the etiology and mechanism revealed that the fracture was initiated by fatigue-related failure and completed by ductile failure on the posterior side of the fracture. Considering the recent trend of treating an intertrochanteric fracture with hip arthroplasty, possible stem failure should be considered, since most patients will have at least one of the known risk factors for stem fracture.

  14. Low-Intensity Pulsed Ultrasound and Halo Immobilization Is an Effective Treatment for Nonunion Following Traumatic Spondylolisthesis of the Axis.

    Science.gov (United States)

    Oda, Kohtaroh; Ohba, Tetsuro; Ebata, Shigeto; Haro, Hirotaka

    2017-10-01

    This case report describes a unique case involving traumatic spondylolisthesis of the axis that resulted in nonunion, angulation, and displacement after conservative treatment with a cervical collar, but which was successfully achieved union with halo immobilization and low-intensity pulsed ultrasound (LIPUS). Halo immobilization of a traumatic spondylolisthesis in a 20-year-old patient, that previously failed to improve after wearing a cervical collar for 3 months, was immediately followed by treatment with a LIPUS device (SAFHS 4000J; Teijin Pharma, Tokyo, Japan) 20 minutes once daily to the right and left fracture sites which were located using fluoroscopic guidance. Radiographs and computed tomography showed conclusive evidence of bone union after 10 weeks of treatment with halo immobilization. No adverse events were observed. To the best of our knowledge, this is the first report describing that the combination of halo immobilization and LIPUS therapy might be a safe, effective, and feasible method by which to treat cervical spine fractures.

  15. Management of displaced inferior patellar pole fractures with modified tension band technique combined with cable cerclage using Cable Grip System.

    Science.gov (United States)

    Yang, Xu; Wu, Qinfen; Lai, Chin-Hui; Wang, Xin

    2017-10-01

    We present a modified tension band technique combined with cable cerclage using Cable Grip System for the treatment of displaced inferior patellar pole fractures and report the knee functional outcome. The patients who had had operative treatment of a displaced inferior patellar pole fracture (AO/OTA 34-A1) between December 2013 and December 2015 were studied retrospectively. Eleven consecutive patients had had open reduction and internal fixation with the modified technique using Cable Grip System, of whom, five males and six females with an average age of 60.9 years (range, 29-81 years). All fractures occurred from direct fall onto the knee. The average time from injury to surgery was 6.1days (range, 2-12days). The range of motion (ROM) was measured in degrees by goniometry at postoperative intervals of 1, 2, 4, 12, and 48 weeks; Knee function was evaluated using the Rasmussen scores at final follow-up. No patients had nonunion, loss of reduction, migration of wire, irritation from the implant and fixation breakage during the follow-up period. Recovery of ROM was achieved at 12 weeks, with the average ROM at 1 week was 72° (range, 65°-78°), 86.4° (range, 78°-92°) at 2 weeks, 115.5° (range, 103°-122°) at 4 weeks, 129.6° (range, 122°-133°) at 12 weeks, 134.5° (range, 129°-139°) at 48 weeks after the operation. Concerning the knee function outcome assessment, all patients showed excellent results at final follow-up. The average Rasmussen scores was 27.9 out of 30 (range, 27-29). The modified tension band technique combined with cable cerclage using Cable Grip System for displaced inferior patellar pole fractures can provide stable fixation with excellent results in knee function, allows for immediate mobilization and early weight-bearing, which is a simple and valuable technique in routine clinical practice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Solar Open Flux Migration from Pole to Pole: Magnetic Field Reversal.

    Science.gov (United States)

    Huang, G-H; Lin, C-H; Lee, L C

    2017-08-25

    Coronal holes are solar regions with low soft X-ray or low extreme ultraviolet intensities. The magnetic fields from coronal holes extend far away from the Sun, and thus they are identified as regions with open magnetic field lines. Coronal holes are concentrated in the polar regions during the sunspot minimum phase, and spread to lower latitude during the rising phase of solar activity. In this work, we identify coronal holes with outward and inward open magnetic fluxes being in the opposite poles during solar quiet period. We find that during the sunspot rising phase, the outward and inward open fluxes perform pole-to-pole trans-equatorial migrations in opposite directions. The migration of the open fluxes consists of three parts: open flux areas migrating across the equator, new open flux areas generated in the low latitude and migrating poleward, and new open flux areas locally generated in the polar region. All three components contribute to the reversal of magnetic polarity. The percentage of contribution from each component is different for different solar cycle. Our results also show that the sunspot number is positively correlated with the lower-latitude open magnetic flux area, but negatively correlated with the total open flux area.

  17. Second harmonic generation from corona-poled polymer thin films ...

    Indian Academy of Sciences (India)

    2014-02-09

    Feb 9, 2014 ... We characterize thermal stability of second harmonic generation (SHG) properties of four different Y-type polymers poled using corona poling method. These polymers are based on donor–acceptor–donor-type repeating unit with different aromatic moieties acting as donors and dicyanomethylene acting as ...

  18. Poles of the S matrix for a complex potential

    International Nuclear Information System (INIS)

    Dabrowski, J.

    1996-01-01

    Trajectories of S matrix poles in complex k plane are presented for a complex square well potential. A simple rule is given for predicting the effect of an absorptive potential on the location of these poles. copyright 1996 The American Physical Society

  19. Secondary electron emission yield on poled silica based thick films

    DEFF Research Database (Denmark)

    Braga, D.; Poumellec, B.; Cannas, V.

    2004-01-01

    Studies on the distribution of the electric field produced by a thermal poling process in a layer of Ge-doped silica on silicon substrate, by using secondary electron emission yield (SEEY) measurements () are presented. Comparing 0 between poled and unpoled areas, the SEEY at the origin of electr...

  20. Derivation of nominal strength for wood utility poles

    Science.gov (United States)

    Ronald W. Wolfe; Jozsef Bodig; Patricia Lebow

    2001-01-01

    The designated fiber stress values published in the American National Standards Institute Standard for Poles, ANSI 05.1, no longer reflect the state of the knowledge. These values are based on a combination of test data from small clear wood samples and small poles (

  1. Removal of well-fixed components in femoral revision arthroplasty with controlled segmentation of the proximal femur.

    Science.gov (United States)

    Megas, Panagiotis; Georgiou, Christos S; Panagopoulos, Andreas; Kouzelis, Antonis

    2014-12-31

    The transfemoral and the extended trochanteric osteotomies are the most common osteotomies used in femoral revision, both when proximal or diaphyseal fixation of the new component has been decided. We present an alternative approach to the trochanteric osteotomies, most frequently used with distally fixated stems, to overcome their shortcomings of osteotomy migration and nonunion, but, most of all, the uncontrollable fragmentation of the femur. The procedure includes a complete circular femoral osteotomy just below the stem tip to prevent distal fracture propagation and a subsequent preplanned segmentation of the proximal femur for better exposure and fast removal of the old prosthesis. The bone fragments are reattached with cerclage wires to the revision prosthesis, which is safely anchored distally. A modified posterolateral approach is used, as the preservation of the continuity of the abductors, the greater trochanter, and the vastus lateralis is a prerequisite. Between 2006 and 2012, 47 stems (33 women, 14 men, mean age 68 years, range 39-88 years) were revised using this technique. They were 12 (26%) stable and 35 (74%) loose prostheses and were all revised to tapered, fluted, grit-blasted stems. No fracture of the trochanters or the distal femur occurred intraoperatively. Mean follow-up was 28 months (range 6-70 months). No case of trochanteric migration or nonunion of the osteotomies was recorded. Restoration of the preexisting bone defects occurred in 83% of the patients. Three patients required repeat revision due to dislocation and one due to a postoperative periprosthetic fracture. None of the failures was attributed to the procedure itself. This new osteotomy technique may seem aggressive at first, but, at least in our hands, has effectively increased the speed of the femoral revision, particularly for the most difficult well-fixed components, but not at the expense of safety.

  2. Pole orientation of 16 Psyche by two independent methods

    Science.gov (United States)

    Tedesco, E. F.; Taylor, R. C.

    1985-01-01

    Nineteen new lightcurves of 16 Psyche are presented along with a pole orientation derived using two independent methods, namely, photometric astrometry and magnitude-amplitude-shape-aspect. The pole orientations found using these two methods agree to within 4 deg. The results from applying photometric astrometry were prograde rotation, a sidereal period of 0.1748143 days + or - 0.0000003 days, and a pole at longitude 223 deg and latitude +37 deg, with an uncertainty of 10 deg, and, from applying magnitude-amplitude-shape-aspect a pole at 220 + or - 1 deg, +40 + or - 4 deg, and a modeled triaxial ellipsoid shape (a greater than b greater than c) and a/b = 1.33 + or - 0.07. The discrepancy between the high-pole latitude found here and the low latitudes reported by Lupishko et al. (1982) and Zhou and Yang (1982) is discussed.

  3. Management of the proximal tibia fractures by mini external fixation: A case series of 30 cases

    Directory of Open Access Journals (Sweden)

    Samar K Biswas

    2014-01-01

    Full Text Available Background: Management of high velocity trauma is a challenging problem because of morbidity of trauma and sometime residual problems of failure of proper healing of fractures with the restriction of movements of knee, shortening, and added risk of compartment syndrome in the proximal tibia fracture. There is always risk of post-operative infection and infected non-union in extensive open surgical procedure and internal fixation. Hence, there is always look out for the middle path procedure for a solution to the above said problems with the added advantage of less hospital stay and early return to work by minimal invasive procedure and stabilization of fracture reduction by multiple K-wire fixation with a frame applied externally. Stabilization of fracture with reduced pain allows early movements of neighbouring joint knee and ankle; hence, reduces the chances of fracture diseases. With this we have been stimulated to take-up the study of managing the proximal tibia fracture by mini external fixator. Aim: The aim of this study was to manage proximal tibia fractures by mini external fixator and evaluate the results and efficacy of this method. Material and Method: A total of 30 patients having proximal tibial fractures admitted at our center between 2008 and 2010 were taken and the procedure carried out was closed manipulative reduction and stabilization with mini external fixator. All acute proximal tibia fractures including tibial plateau fractures above 17 years of age of either sex were included in the study. Fracture more than 3 weeks old were excluded from the study. Result: Out of 30 cases 13 were excellent, 14 cases good, and 3 showed fair. It was found that type 5 and 6 of Schatzker′s classification have lesser outcome type of fractures Conclusion: We have found that management of the proximal tibia fractures by mini external fixation method has a better outcome. Early mobilization of knee in the proximal tibia fractures after

  4. Pole Dancing Auto-ethnography – Practice, Pedagogy, Performance

    Directory of Open Access Journals (Sweden)

    Amy Patricia Cadwallader

    2017-02-01

    Full Text Available In this research paper, the author addresses the following four questions: 1 What are the implications of bringing pole dancing into concert dance, not as a caricature or theatrical version of what is performed in strip clubs, but as its own, free-standing art form? 2 In what ways will years of ballet and modern dance training influence the type of dancing that emerges from dancers when poles and other apparatuses are introduced? 3 How can the author create an original pole dancing style and pedagogical methods for teaching it? 4 Who participates in pole fitness classes and how does the demographic change based on location? What about when pole fitness classes are offered in an academic setting? The author shares first-hand experiences of investigating pole dancing in fitness classes, attending performances, engaging in a rehearsal process with highly trained dancers, and teaching pole dancing to movers with a wide range of abilities. The author addresses how research plans changed as she encountered limitations of budget and time constraints. The author also elaborates on the creative process that she engaged in with her thesis cast, collaborators, and supporting designers in the making of Super-beneath, a theatrical dance work that uses five, free-standing poles. She outline the vignettes, overall structure, and narrative of the work. The author then discusses where this research fits into the larger field of pole dancing, and the even larger field of dance. In the final sections of this paper, the author describes her pedagogical practices relating to pole classes, what “practice as research” means to her, and how she would like to continue on this research trajectory in the future.

  5. Simplified Analytic Approach of Pole-to-Pole Faults in MMC-HVDC for AC System Backup Protection Setting Calculation

    Directory of Open Access Journals (Sweden)

    Tongkun Lan

    2018-01-01

    Full Text Available AC (alternating current system backup protection setting calculation is an important basis for ensuring the safe operation of power grids. With the increasing integration of modular multilevel converter based high voltage direct current (MMC-HVDC into power grids, it has been a big challenge for the AC system backup protection setting calculation, as the MMC-HVDC lacks the fault self-clearance capability under pole-to-pole faults. This paper focused on the pole-to-pole faults analysis for the AC system backup protection setting calculation. The principles of pole-to-pole faults analysis were discussed first according to the standard of the AC system protection setting calculation. Then, the influence of fault resistance on the fault process was investigated. A simplified analytic approach of pole-to-pole faults in MMC-HVDC for the AC system backup protection setting calculation was proposed. In the proposed approach, the derived expressions of fundamental frequency current are applicable under arbitrary fault resistance. The accuracy of the proposed approach was demonstrated by PSCAD/EMTDC (Power Systems Computer-Aided Design/Electromagnetic Transients including DC simulations.

  6. Territorial Balancing of Poles of Development

    Directory of Open Access Journals (Sweden)

    CLAUDIA POPESCU

    2008-01-01

    Full Text Available The paper is part of the study "Specific problems of the development of the settlement network in south-eastern Romania. Regions of development 3 (South, 4 (South-West and 8 (Bucharest-Ilfov" elaborated during 2004 – 2006, within the AMTRANS programme funded by the Ministry of Education and Research, coordinated by INCD – URBANPROIECT in partnership with the Institute of Geography of the Romanian Academy and the Qualification in Statistics National Centre. The general objective of the project was sustainable and balanced spatial development of the settlement network and promotion of new relationships between urban and rural. Concretely, the study has produced a model of a polycentric and balanced settlement network according to the European principles. The case study testing and validating this model took place in southern Romania, territory exhibiting acutely the entire range of problems related to the state of the settlement network: profoundly large rural areas, accentuated dynamics of declaring new cities without sufficient evidence, excessive polarization exercised by Bucharest, etc. The paper presents the intervention directions needed to balance in the territory urban poles within the studied area, focusing on the establishment of orientation policies to consolidate the role of each settlement based on the hierarchical level of importance: European, national, regional, and local. The paper also identifies possible functional urban areas: the metropolitan area of Bucharest, areas of potential strategic integration, areas of cooperation between the small and medium-sized cities and the rural regions. Within each of these areas, the paper proposes to establish new relationships between urban and rural based on partnership, involving cooperation and coordination in achieving common goals.The study considers that the poles of development are the key element of proposed model, and their identification, formation, and balanced distribution

  7. Heavy Cratering near Callisto's South Pole

    Science.gov (United States)

    1997-01-01

    Images from NASA's Galileo spacecraft provide new insights into this region near Callisto's south pole. This two frame mosaic shows a heavily cratered surface with smooth plains in the areas between craters. North is to the top of the image. The smoothness of the plains appears to increase toward the south pole, approximately 480 kilometers (293 miles) south of the bottom of the image. This smoothness of Callisto's surface was not evident in images taken during the 1979 flyby of NASA's Voyager spacecraft because the resolution was insufficient to show the effect. This smooth surface, and the process(es) that cause it, are among the most intriguing aspects of Callisto. Although not fully understood, the process(es) responsible for this smoothing could include erosion by tiny meteorites and energetic ions. Some craters, such as Keelut, the 47 kilometer (29 mile) crater in the lower right corner, have sharp, well defined rims. Keelut contains an inner ring surrounding a central depression about 17 kilometers (11 miles) in diameter. Keelut, and the more irregularly shaped, degraded Reginleif, the 32 kilometer (19.5 mile) crater in the top center of the image, are very shallow and have flat floors. Crater forms can be seen down to less than 2 kilometers (1.2 miles) in diameter in the image. Each picture element (pixel) in this image is approximately 0.68 kilometers (0.41 miles) across.This image which was taken by the Galileo spacecraft's solid state imaging (CCD) system during its eighth orbit around Jupiter, on May 6th, 1997. The center of the image is located at 71.3 degrees south latitude, 97.6 degrees west longitude, and was taken when the spacecraft was approximately 35,470 kilometers (21,637 miles) from Callisto.The Jet Propulsion Laboratory, Pasadena, CA manages the mission for NASA's Office of Space Science, Washington, DC.This image and other images and data received from Galileo are posted on the World Wide Web, on the Galileo mission home page at URL http

  8. Pole-factorization theorem in quantum electrodynamics

    International Nuclear Information System (INIS)

    Stapp, H.P.

    1996-01-01

    In quantum electrodynamics a classical part of the S-matrix is normally factored out in order to obtain a quantum remainder that can be treated perturbatively without the occurrence of infrared divergences. However, this separation, as usually performed, introduces spurious large-distance effects that produce an apparent breakdown of the important correspondence between stable particles and poles of the S-matrix, and, consequently, lead to apparent violations of the correspondence principle and to incorrect results for computations in the mesoscopic domain lying between the atomic and classical regimes. An improved computational technique is described that allows valid results to be obtained in this domain, and that leads, for the quantum remainder, in the cases studied, to a physical-region singularity structure that, as regards the most singular parts, is the same as the normal physical-region analytic structure in theories in which all particles have non-zero mass. The key innovations here are to define the classical part in coordinate space, rather than in momentum space, and to define there a separation of the photon-electron coupling into its classical and quantum parts that has the following properties: (1) The contributions from the terms containing only classical couplings can be summed to all orders to give a unitary operator that generates the coherent state that corresponds to the appropriate classical process, and (2) The quantum remainder can be rigorously shown to exhibit, as regards its most singular parts, the normal analytic structure. 22 refs

  9. π π scattering by pole extrapolation methods

    International Nuclear Information System (INIS)

    Lott, F.W. III.

    1978-01-01

    A 25-inch hydrogen bubble chamber was used at the Lawrence Berkeley Laboratory Bevatron to produce 300,000 pictures of π + p interactions at an incident momentum of the π + of 2.67 GeV/c. The 2-prong events were processed using the FSD and the FOG-CLOUDY-FAIR data reduction system. Events of the nature π + p→π + pπ 0 and π + p→π + π + n with values of momentum transfer to the proton of -t less than or equal to 0.238 GeV 2 were selected. These events were used to extrapolate to the pion pole (t = m/sub π/ 2 ) in order to investigate the π π interaction with isospins of both T=1 and T=2. Two methods were used to do the extrapolation: the original Chew-Low method developed in 1959 and the Durr-Pilkuhn method developed in 1965, which takes into account centrifugal barrier penetration factors. At first it seemed that, while the Durr-Pilkuhn method gave better values for the total π π cross section, the Chew-Low method gave better values for the angular distribution. Further analysis, however, showed that, if the requirement of total OPE (one-pion-exchange) was dropped, then the Durr-Pilkuhn method gave more reasonable values of the angular distribution as well as for the total π π cross section

  10. π π scattering by pole extrapolation methods

    International Nuclear Information System (INIS)

    Lott, F.W. III.

    1977-01-01

    A 25-inch hydrogen bubble chamber was used at the Lawrence Berkeley Laboratory Bevatron to produce 300,000 pictures of π + p interactions at an incident momentum of the π + of 2.67 GeV/c. The 2-prong events were processed using the FSD and the FOG-CLOUDY-FAIR data reduction system. Events of the nature π + p → π + pπ 0 and π + p → π + π + n with values of momentum transfer to the proton of -t less than or equal to 0.238 GeV 2 were selected. These events were used to extrapolate to the pion pole (t = m/sub π/ 2 ) in order to investigate the π π interaction with isospins of both T = 1 and T = 2. Two methods were used to do the extrapolation: the original Chew-Low method developed in 1959 and the Durr-Pilkuhn method developed in 1965 which takes into account centrifugal barrier penetration factors. At first it seemed that, while the Durr-Pilkuhn method gave better values for the total π π cross section, the Chew-Low method gave better values for the angular distribution. Further analysis, however, showed that if the requirement of total OPE (one-pion-exchange) were dropped, then the Durr-Pilkuhn method gave more reasonable values of the angular distribution as well as for the total π π cross section

  11. Time domain oscillating poles: Stability redefined in Memristor based Wien-oscillators

    KAUST Repository

    Talukdar, Abdul Hafiz Ibne; Radwan, Ahmed G.; Salama, Khaled N.

    2012-01-01

    poles. The idea is verified using a Memristor based Wien oscillator. Sustained oscillations are observed without having the poles of the system fixed on the imaginary axis and the oscillating behavior of the system poles is reported. The oscillating

  12. Plate Fixation With Autogenous Calcaneal Dowel Grafting Proximal Fourth and Fifth Metatarsal Fractures: Technique and Case Series.

    Science.gov (United States)

    Seidenstricker, Chad L; Blahous, Edward G; Bouché, Richard T; Saxena, Amol

    Metaphyseal and proximal diaphyseal fractures of the lateral column metatarsals can have problems with healing. In particular, those involving the fifth metatarsal have been associated with a high nonunion rate with nonoperative treatment. Although intramedullary screw fixation results in a high union rate, delayed healing and complications can occur. We describe an innovative technique to treat both acute and chronic injuries involving the metatarsal base from the metaphysis to the proximal diaphyseal bone of the fourth and fifth metatarsals. The surgical technique involves evacuation of sclerotic bone at the fracture site, packing the fracture site with compact cancellous bone, and plate fixation. In our preliminary results, 4 patients displayed 100% radiographic union at a mean of 4.75 (range 4 to 6) weeks with no incidence of refracture, at a mean follow-up point of 3.5 (range 1 to 5) years. The early results with our small series suggest that this technique is a useful treatment choice for metaphyseal and proximal diaphyseal fractures of the fourth and fifth metatarsals. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  13. In Situ Poling and Imidization of Amorphous Piezoelectric Polyimides

    Science.gov (United States)

    Park, Cheol; Ounaies, Zoubeida; Wise, Kristopher E.; Harrison, Joycelyn S.; Bushnell, Dennis M. (Technical Monitor)

    2002-01-01

    An amorphous piezoelectric polyimide containing polar functional groups has been developed using a combination of experimental and molecular modeling for potential use in high temperature applications. This amorphous polyimide, (Beta-CN)APB/ODPA, has exhibited good thermal stability and piezoelectric response at temperatures up to 150C. Density functional calculations predicted that a partially cured amic acid (open imide ring) possesses a dipole moment four times larger than the fully imidized closed ring. In situ poling and imidization of the partially cured (Beta-CN)APB/ODPA, was studied in an attempt to maximize the degree of dipolar orientation and the resultant piezoelectric response. A positive corona poling was used to minimize localized arcing during poling and to allow use of higher poling fields without dielectric breakdown. The dielectric relaxation strength, remanent polarization, and piezoelectric response were evaluated as a function of the poling profile. The partially cured, corona poled polymers exhibited higher dielectric relaxation strength (delta varepsilon), remanent polarization (Pr) and piezoelectric strain coefficient (d33) than the fully cured, conventionally poled ones.

  14. Study on Pole Arrangement of the CEDM Coils

    International Nuclear Information System (INIS)

    Park, Jin Seok; Lee, Myoung Goo; Kim, Hyun Min; Cho, Yeon Ho; Choi, Taek Sang

    2013-01-01

    The coil stack assembly is important for reliable operation of the CEDM, there have been efforts to improve the design by optimizing the design parameters such as dimensions and winding turns. However, magnetic forces of the CEDM can also change by different pole arrangement even if their design parameters are the same. Since the latch coil and lift coil are installed connected to each other, they produce magnetically coupled field when they are energized at the same time. This coupling field can affect the magnetic force of the CEDM significantly. In this paper, coil pole arrangement effects are studied. Electro-magnetic analysis is performed for the different pole arrangements of the CEDM coils to calculate the magnetic forces. Pole arrangement effects on magnetic forces were studied by static analysis of the CEDM magnetic field. Magnetic forces were calculated and compared for the two different pole arrangements of the coils. The results show that the magnetic poles of the lift coil and latch coil shall be arranged to have the same magnetic pole direction to achieve higher magnetic force

  15. ProxImaL: efficient image optimization using proximal algorithms

    KAUST Repository

    Heide, Felix

    2016-07-11

    Computational photography systems are becoming increasingly diverse, while computational resources-for example on mobile platforms-are rapidly increasing. As diverse as these camera systems may be, slightly different variants of the underlying image processing tasks, such as demosaicking, deconvolution, denoising, inpainting, image fusion, and alignment, are shared between all of these systems. Formal optimization methods have recently been demonstrated to achieve state-of-the-art quality for many of these applications. Unfortunately, different combinations of natural image priors and optimization algorithms may be optimal for different problems, and implementing and testing each combination is currently a time-consuming and error-prone process. ProxImaL is a domain-specific language and compiler for image optimization problems that makes it easy to experiment with different problem formulations and algorithm choices. The language uses proximal operators as the fundamental building blocks of a variety of linear and nonlinear image formation models and cost functions, advanced image priors, and noise models. The compiler intelligently chooses the best way to translate a problem formulation and choice of optimization algorithm into an efficient solver implementation. In applications to the image processing pipeline, deconvolution in the presence of Poisson-distributed shot noise, and burst denoising, we show that a few lines of ProxImaL code can generate highly efficient solvers that achieve state-of-the-art results. We also show applications to the nonlinear and nonconvex problem of phase retrieval.

  16. Risk Factors for Non-:union: Fractures of the Clavicle Mid-shift Following the Use of Non-surgical Treatment on Patients Admitted to Poursina Hospital, 2010 - 2012

    Directory of Open Access Journals (Sweden)

    kamran Asadi

    2015-02-01

    Conclusions: Recognition and predicting the risk factors of non-:::union::: in patients with fractures of the middle third of the clavicle could be a clinical guideline for the selection of surgical or non-surgical treatment.

  17. The self-consistent dynamic pole tide in global oceans

    Science.gov (United States)

    Dickman, S. R.

    1985-01-01

    The dynamic pole tide is characterized in a self-consistent manner by means of introducing a single nondifferential matrix equation compatible with the Liouville equation, modelling the ocean as global and of uniform depth. The deviations of the theory from the realistic ocean, associated with the nonglobality of the latter, are also given consideration, with an inference that in realistic oceans long-period modes of resonances would be increasingly likely to exist. The analysis of the nature of the pole tide and its effects on the Chandler wobble indicate that departures of the pole tide from the equilibrium may indeed be minimal.

  18. Domain wall width of lithium niobate poled during growth

    CERN Document Server

    Brooks, R; Hole, D E; Callejo, D; Bermudez, V; Diéguez, E

    2003-01-01

    Good quality crystals of periodically poled lithium niobate can be generated directly during growth. However, the temperature gradients at the zone boundaries define the width of the regions where the polarity is reversed. Hence, the region influenced the domain transition may be a significant fraction of the overall poling period for material poled during growth. Evidence for the scale of this feature is reported both by chemical etching and by the less common method of ion beam luminescence and the 'domain wall' width approximately 1 mu m for these analyses. The influence of the reversal region may differ for alternative techniques but the relevance to device design for second harmonic generation is noted.

  19. A discussion on leading renormalon in the pole mass

    Science.gov (United States)

    Komijani, J.

    2017-08-01

    Perturbative series of some quantities in quantum field theories, such as the pole mass of a quark, suffer from a kind of divergence called renormalon divergence. In this paper, the leading renormalon in the pole mass is investigated, and a map is introduced to suppress this renormalon. The inverse of the map is then used to generate the leading renormalon and obtain an expression to calculate its overall normalization. Finally, the overall normalization of the leading renormalon of the pole mass is calculated for several values of quark flavors.

  20. State-PID Feedback for Pole Placement of LTI Systems

    Directory of Open Access Journals (Sweden)

    Sarawut Sujitjorn

    2011-01-01

    Full Text Available Pole placement problems are especially important for disturbance rejection and stabilization of dynamical systems and regarded as algebraic inverse eigenvalue problems. In this paper, we propose gain formulae of state feedback through PID-elements to achieve desired pole placement for a delay-free LTI system with single input. Real and complex stable poles can be assigned with the proposed compact gain formulae. Numerical examples show that our proposed gain formulae can be used effectively resulting in very satisfactory responses.

  1. Electromagnetic properties of proximity systems

    Science.gov (United States)

    Kresin, Vladimir Z.

    1985-07-01

    Magnetic screening in the proximity system Sα-Mβ, where Mβ is a normal metal N, semiconductor (semimetal), or a superconductor, is studied. Main attention is paid to the low-temperature region where nonlocality plays an important role. The thermodynamic Green's-function method is employed in order to describe the behavior of the proximity system in an external field. The temperature and thickness dependences of the penetration depth λ are obtained. The dependence λ(T) differs in a striking way from the dependence in usual superconductors. The strong-coupling effect is taken into account. A special case of screening in a superconducting film backed by a size-quantizing semimetal film is considered. The results obtained are in good agreement with experimental data.

  2. Electromagnetic properties of proximity systems

    International Nuclear Information System (INIS)

    Kresin, V.Z.

    1985-01-01

    Magnetic screening in the proximity system S/sub α/-M/sub β/, where M/sub β/ is a normal metal N, semiconductor (semimetal), or a superconductor, is studied. Main attention is paid to the low-temperature region where nonlocality plays an important role. The thermodynamic Green's-function method is employed in order to describe the behavior of the proximity system in an external field. The temperature and thickness dependences of the penetration depth lambda are obtained. The dependence lambda(T) differs in a striking way from the dependence in usual superconductors. The strong-coupling effect is taken into account. A special case of screening in a superconducting film backed by a size-quantizing semimetal film is considered. The results obtained are in good agreement with experimental data

  3. Quality of life and complications at the different stages of bone transport for treatment infected nonunion of the tibia.

    Science.gov (United States)

    Wang, Hu; Wei, Xing; Liu, Ping; Fu, Ya-Hui; Wang, Peng-Fei; Cong, Yu-Xuan; Zhang, Bin-Fei; Li, Zhong; Lei, Jin-Lai; Zhang, Kun; Zhuang, Yan

    2017-11-01

    The aim of this study was to assess Physical Component Summary (PCS), Mental Component Summary (MCS) of the Mos 36-item Short Form Health Survey (SF-36) score, and the virtual Analogue Scale (VAS) of pain during the treatment period and the complication rate associated with infected nonunion of the tibia managed surgically by bone transport.This is a retrospective analysis of prospectively collected data in a consecutive patient cohort. Patients suffering from infected nonunion of the tibia were treated by bone transport from 2012 to 2014. Follow-up was for at least 2 years after complete osseous consolidation. Standardized treatment included bacterial eradication by segmental resection, bone transport using Ilizarov apparatus, and docking maneuver. The main outcome measurements consisted of the quality of life (PCS and MCS scores) and the VAS of pain during the different stages of therapy. In addition, all complications were documented.Our series comprised 12 men and 3 women with an average age of 36.9 years (range: 20-55 years). All patients previously undergone an average of 2.9 operations (range: 1-6 operations). In all patients, bone defects were present with a mean size of 7.5 cm (range: 3-12 cm), and all patients were suffering from soft tissue defects (range: 5-17 cm). The mean external fixator time (EFT) was 48 weeks (range: 30-62 weeks) and the mean external fixation index was 43.1 days/cm (range: 33-62 days/cm). All patients achieved bone union, and no recurrence of infection was observed. According to the Paley classification, patients suffered 15 minor and 13 major complications. The average complication rate per patient comprised of 1.0 minor and 0.9 major complications. Bone grafting was required in 6 cases at the docking site. One patient suffered from equinus deformity, and refused any further surgical procedures. We performed 28 operations in 15 patients (average 1.9 operations per patient). After the period of bone transport, PCS and MCS

  4. Proximity effect at Millikelvin temperatures

    International Nuclear Information System (INIS)

    Mota, A.C.

    1986-01-01

    Proximity effects have been studied extensively for the past 25 years. Typically, they are in films several thousand angstroms thick at temperatures not so far below T/sub CNS/, the transition temperature of the NS system. Interesting is, however, the proximity effect at temperatures much lower than T/sub CNS/. In this case, the Cooper-pair amplitudes are not small and very long pair penetration lengths into the normal metal can be expected. Thus, we have observed pair penetration lengths. For these investigations very suitable specimens are commercial wires of one filament of NbTi or Nb embedded in a copper matrix. The reasons are the high transmission coefficient at the interface between the copper and the superconductor and the fact that the copper in these commercial wires is rather clean with electron free paths between 5 to 10 μm long. In this paper, the magnetic properties of thick proximity systems in the range of temperatures between T/sub CNS/ and 5 x 10/sup -4/ T/sub CNS/ in both low and high magnetic fields are discussed

  5. Management of knee rheumatoid arthritis and tibia nonunion with one-stage total knee arthroplasty and intramedullary nailing: A report of two cases

    Directory of Open Access Journals (Sweden)

    Fahri Erdogan

    2018-01-01

    Full Text Available Total knee arthroplasty (TKA is a surgical procedure which is widely used in the treatment of gonarthrosis secondary to rheumatoid arthritis (RA. The incidence of stress fractures in tibia in the patients with RA is higher compared to normal patients. In this study, we report two cases of TKA and intramedullary nailing in RA patients with severe knee arthritis and tibial nonunion. Both patients had a satisfactory clinical outcome with radiological healing of the tibial fracture.

  6. Effect on Clinical Outcome and Growth Factor Synthesis With Adjunctive Use of Pulsed Electromagnetic Fields for Fifth Metatarsal Nonunion Fracture: A Double-Blind Randomized Study.

    Science.gov (United States)

    Streit, Adam; Watson, B Collier; Granata, Jaymes D; Philbin, Terrence M; Lin, Hsuan-Ni; O'Connor, J Patrick; Lin, Sheldon

    2016-09-01

    Electromagnetic bone growth stimulators have been found to biologically enhance the bone healing environment, with upregulation of numerous growth factors. The purpose of the study was to quantify the effect, in vivo, of pulsed electromagnetic fields (PEMFs) on growth factor expression and healing time in fifth metatarsal nonunions. This was a prospective, randomized, double-blind trial of patients, cared for by 2 fellowship-trained orthopedic foot and ankle surgeons. Inclusion criteria consisted of patients between 18 and 75 years old who had been diagnosed with a fifth metatarsal delayed or nonunion, with no progressive signs of healing for a minimum of 3 months. Eight patients met inclusion criteria and were randomized to receive either an active stimulation or placebo PEMF device. Each patient then underwent an open biopsy of the fracture site and was fitted with the appropriate PEMF device. The biopsy was analyzed for messenger-ribonucleic acid (mRNA) levels using quantitative competitive reverse transcription polymerase chain reaction (QT-RT-PCR). Three weeks later, the patient underwent repeat biopsy and open reduction and internal fixation of the nonunion site. The patients were followed at 2- to 4-week intervals with serial radiographs and were graded by the number of cortices of healing. All fractures healed, with an average time to complete radiographic union of 14.7 weeks and 8.9 weeks for the inactive and active PEMF groups, respectively. A significant increase in placental growth factor (PIGF) level was found after active PEMF treatment (P = .043). Other factors trended higher following active PEMF including brain-derived neurotrophic factor (BDNF), bone morphogenetic protein (BMP) -7, and BMP-5. The adjunctive use of PEMF for fifth metatarsal fracture nonunions produced a significant increase in local placental growth factor. PEMF also produced trends toward higher levels of multiple other factors and faster average time to radiographic union

  7. TO EVALUATE THE SURGICAL OUTCOME OF NON-UNION CLAVICLE USING PLATE AND SLIVERS OF AUTOLOGOUS ILIAC CREST CORTICOCANCELLOUS BONE GRAFT

    Directory of Open Access Journals (Sweden)

    Mohammed

    2016-03-01

    Full Text Available INTRODUCTION Clavicle fracture is one of the most common fracture presenting to the fracture clinic, accounting for about 5-10% of all the adult trauma reported but still the controversy exists with regards to the definitive management. AIM To evaluate the surgical outcome of nonunion clavicle in patients treated previously with surgical management or conservative management, using plate and slivers of autologous iliac crest corticocancellous bone. DESIGN Retrospective analysis of patients operated between May 2005 and February 2013 for nonunion of the clavicle. METHODS AND MATERIALS Twenty patients who were operated between May 2005 and February 2013 for nonunion of the clavicle at our hospital were recruited for our study and followup data was collected from our hospital records till their last outpatient visit. Inclusion criteria included patients with no evidence of radiological union, persistence of pain, cosmetic deformity, dysfunction or gross movement at the fracture site even after 16 weeks of conservative treatment or in cases of primary fixation failure. STATISTICAL ANALYSIS All Statistical analyses were made using Statistical Package Software for Social Sciences (SPSS version 17.0 software (Chicago, IL, USA for descriptive data. Chi2 test was used to compare the categorical data. RESULTS At the end of an average followup of 19 months, the average Visual Analogue Score for pain was 1.9±2.2 (range 0-6, the mean ASES score was 81±18.5 (51-100, and the mean Constant–Murley score was 80±17 (51-100. All the patients had a stable radiological union at the end of the followup period. There were no complications pertaining to the hardware or infection. CONCLUSION Treatment of nonunion of clavicle by using corticocancellous bone is well documented; however, use of iliac corticocancellous bone graft shaped in long slivers will give mechanical stability to the plate reconstruct in addition to providing a scaffold for new bone formation than

  8. Pole-zero adjustment of spectroscopy amplifiers using multichannel analyzers

    Energy Technology Data Exchange (ETDEWEB)

    Ianakiev, K; Grigorov, T [Inst. for Nuclear Research and Nuclear Energy, Sofia (Bulgaria)

    1996-12-31

    The technique to eliminate the undesirable undershoot in the output signal of a spectroscopy amplifier is considered. The functional scheme of the pole-zero monitoring circuit is presented as well as its operation principles are considered. 3 refs.

  9. Pacific Albacore Troll and Pole-and-line Fisheries

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The North Pacific and South Pacific Albacore Troll and Pole-and-line Fisheries project contains landings, logbooks, and size composition data from U.S.A. troll and...

  10. The Achievements of the GLAMOROUS Project on Poling

    DEFF Research Database (Denmark)

    Margulis, Walter; Myrén, N.; Fage-Pedersen, Jacob

    2005-01-01

    The GLAMOROUS project had as objective to demonstrate the feasibility of fibre and waveguide components with a second order nonlinearity induced by poling. The accomplishments of this nine-partners European Research Project are described.......The GLAMOROUS project had as objective to demonstrate the feasibility of fibre and waveguide components with a second order nonlinearity induced by poling. The accomplishments of this nine-partners European Research Project are described....

  11. Polymer poling characterization using second harmonic generation (SHG)

    Science.gov (United States)

    Tellier, Gildas; Averty, Dominique; Blart, Errol; Boisrobert, Christian; Gundel, Hartmut; Le Tacon, Sylvain; Monnereau, Cyrille; Odobel, Fabrice; Seveno, Raynald

    2006-04-01

    Several polymer molecules have structures which are suitable for the non-linear optic applications. We report on the design and fabrication of a high performance electro-optic modulator made of polymer thin films. The polymer we study contains a chromophore based on Disperse Red One covalently grafted to a host-matrix. The polymer materials are deposited in thin layers on a glass substrate by chemical solution deposition, either by spin-coating or by dip-coating. The thickness of the films is ranging from a hundred nanometers to several micrometers. Initially, the polymer molecules are randomly oriented and the films are isotropic, hence no electro-optic effect can be observed. In order to break the symmetry and align the chromophores, the films are submitted to the so-called corona poling process. As a result, their structure become non-centrosymmetric and the second-order susceptibility is no longer zero. The corona poling method consists of applying a high electric field to the polymer by means of a needle electrode, placed above the polymer film which is posed on a grounded sample support electrode. Thermal regulation of the support electrode allows to control the temperature during the poling of the films. Once the poling process has been established, a chemical cross-linking function is thermally activated in order to fix the orientation of the chromophores in the polymer matrix. The orientation and its stability in time is evaluated with a Second Harmonic Generation measurement set-up using the Makers Fringes configuration. We studied the influence of the poling temperature, the distance between the corona needle electrode and the sample, the high voltage applied, and the duration of the poling process on the efficiency of chromophore orientation in order to optimize the poling procedure. Finally, aging of poled polymer samples has been investigated at elevated temperatures, confirming the stability of the cross-linking process.

  12. Multijet final states: exact results and the leading pole approximation

    International Nuclear Information System (INIS)

    Ellis, R.K.; Owens, J.F.

    1984-09-01

    Exact results for the process gg → ggg are compared with those obtained using the leading pole approximation. Regions of phase space where the approximation breaks down are discussed. A specific example relevant for background estimates to W boson production is presented. It is concluded that in this instance the leading pole approximation may underestimate the standard QCD background by more than a factor of two in certain kinematic regions of physical interest

  13. Second-harmonic scanning optical microscopy of poled silica waveguides

    DEFF Research Database (Denmark)

    Pedersen, Kjeld; Bozhevolnyi, Sergey I.; Arentoft, Jesper

    2000-01-01

    Second-harmonic scanning optical microscopy (SHSOM) is performed on electric-field poled silica-based waveguides. Two operation modes of SHSOM are considered. Oblique transmission reflection and normal reflection modes are used to image the spatial distribution of nonlinear susceptibilities...... and limitations of the two operation modes when used for SHSOM studies of poled silica-based waveguides are discussed. The influence of surface defects on the resulting second-harmonic images is also considered. ©2000 American Institute of Physics....

  14. Ipsilateral Femoral Fracture Non-Union and Delayed Union Treated By Hybrid Plate Nail Fixation and Vascularized Fibula Bone Grafting: A Case Report

    Directory of Open Access Journals (Sweden)

    CK Chan

    2013-07-01

    Full Text Available Non-union is a well recognized complication of femoral neck fractures. The decision whether to attempt fracture fixation or to resort to hip replacement is particularly difficult in patients in the borderline age group in whom complex attempts at gaining union may fail and later present a difficult revision. On the other hand the patient may be young enough that arthroplasty best be avoided . Besides, presence of ipsilateral femoral shaft fracture with delayed union in addition to the femoral neck non-union will pose major problems at operation. We share our experience in treating a femoral neck fracture non-union with ipsilateral femoral shaft delayed union in the shaft and in the distal femur in a fifty years old patient. The fracture was treated with an angle blade plate and supracondylar nail supplemented with a free vascularised fibular bone grafting and autologous cancellous graft. There was radiological union at fourth month. At sixth months, the patient was free of pain and able to walk without support. Thus, we would like to suggest that vascularised fibula bone grafting with supracondylar nailing is a viable option for this pattern of fracture.

  15. The use of bone morphogenic protein-7 (OP-1) in the management of resistant non-unions in the upper and lower limb.

    Science.gov (United States)

    Papanna, M C; Al-Hadithy, N; Somanchi, B V; Sewell, M D; Robinson, P M; Khan, S A; Wilkes, R A

    2012-07-01

    The aim of the present study was to investigate the safety and efficacy of local implantation of BMP-7 for the treatment of resistant non-unions in the upper and lower limb. Fifty-two patients (30 males, mean age 52.8 years; range 20-81) were treated with local BMP-7 implantation in a bovine bone-derived collagen paste with or without revision of fixation. Thirty-six patients had closed injuries, ten had open injuries and six had infected non-unions. Patients had undergone a mean of 2 (1-5) operations prior to implantation of BMP-7. Clinical and radiological union was achieved in 94% at a mean time of 5.6 months (3-19). Two patients with subtrochanteric femoral fractures failed to achieve union secondary to inadequate fracture stabilisation, persistent unfavourable biological environment and systemic co-morbidities. One patient developed synostosis attributed to the BMP-7 application. This study demonstrates BMP-7 implanted in a bovine-derived collagen paste is an effective adjunctive treatment for resistant non-unions in the upper and lower limb. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Combined Use of Mesenchymal Stromal Cell Sheet Transplantation and Local Injection of SDF-1 for Bone Repair in a Rat Nonunion Model.

    Science.gov (United States)

    Chen, Guangnan; Fang, Tingting; Qi, Yiying; Yin, Xiaofan; Di, Tuoyu; Feng, Gang; Lei, Zhong; Zhang, Yuxiang; Huang, Zhongming

    2016-10-01

    Bone nonunion treatments pose a challenge in orthopedics. This study investigated the joint effects of using mesenchymal stem cell (MSC) sheets with local injection of stromal cell-derived factor-1 (SDF-1) on bone formation. In vitro, we found that migration of MSCs was mediated by SDF-1 in a dose-dependent manner. Moreover, stimulation with SDF-1 had no direct effect on the proliferation or osteogenic differentiation of MSCs. Furthermore, the results indicated elevated expression levels of bone morphogenetic protein 2, alkaline phosphatase, osteocalcin, and vascular endothelial growth factor in MSC sheets compared with MSCs cultured in medium. New bone formation in fractures was evaluated by X-ray, micro-computed tomography (micro-CT), hematoxylin and eosin (H&E) staining, Safranin-O staining, and immunohistochemistry in vivo. In the rat bone fracture model, the MSC sheets transplanted into the injured site along with injection of SDF-1 showed significantly more new bone formation within the gap. Moreover, at 8 weeks, complete bone union was obtained in this group. In contrast, the control group showed nonunion of the bone. Our study suggests a new strategy involving the use of MSC sheets with a local injection of SDF-1 for hard tissue reconstruction, such as the healing of nonunions and bone defects.

  17. Pressure transmitter surveillance: the dominant real pole case

    International Nuclear Information System (INIS)

    Blazquez, J.; Ballestrin, J.

    1995-01-01

    There are about 500 pressure transmitters in a nuclear power plant. Due to Safety requirements, some of them must be specially surveilled. Sensor response time to a pressure ramp is the usual quantity to be measured. Response time, τ r , reflects the dynamics of the sensor and the sensing line. A real pole is due to the inner sensor structure, but the complex pole stands for the sensing line too. The real pole usually is the dominant in most sensors. On line monitoring noise analysis regards simultaneously both, the sensor and the sensing line, but the noise signal contains not only the sensor poles, but many others coming from the plant, so must be conditioned previously and the determination of τ r is not free of systematic errors. That is the price to be paid for non disturbing the plant. When the real pole is dominant, the sensing line contribution is negligible, so the on line noise monitoring methods are supported by the laboratory experiments and the real pole border in the PSD is properly identified. The mean square frequency results proportional to τ r -1 , so manual techniques are designed for response time surveillance made by non noise plant's maintenance technicians. (author)

  18. A poling study on lead zirconate titanate composition

    International Nuclear Information System (INIS)

    Bryant, P.J.

    1992-01-01

    Ceramics produced by the conventional mixed oxide route are dual phased. Because the titania and zirconia are not perfectly homogenized, some parts of the ceramic are more tetragonal (titanium rich) and other parts more rhombohedral (zirconium rich). This inhomogeneity means that some domains can be more easily poled than others. Lastly, the density and porosity can affect the poling process if the flaw density becomes such that the breakdown voltage is exceeded by the required poling voltage. The phase boundary determined by most dielectric and piezoelectric measurements is significantly removed from the 44% titanium content determined by neutron diffraction. The indicators that are most consistent with this value are the minimum in the poling efficiency curve and the shape of the dissipative factor curve. The reason for the discrepancy appears to be related to the broad coexistence region of the two phases and the differing poling efficiencies of each phase. It has been established that different poling temperature profiles can substantially modify the observed properties. Such behaviour is again related to the inhomogeneity of the ceramic and the presence of the two phases. 4 refs., 5 figs

  19. International Youth Conference on the Poles

    Science.gov (United States)

    Church, A. K.; Kuhn, T. S.; Baeseman, J.; Garmulewicz, A.; Raymond, M.; Salmon, R.

    2006-12-01

    The International Polar Year (IPY) is an international effort, involving more than 50 countries, to focus research in both the sciences and social sciences on the world's Polar Regions. In order to secure youth involvement in the IPY, the Youth Steering Committee (YSC) has been formed, aiming specifically to network young polar researchers from all backgrounds enabling collaboration and to involve this group in outreach focused towards other young people. A conference targeted directly at an audience of early career researchers and international youth will be central to fulfilling these aims. The YSC has therefore developed the concept of the International Youth Conference on the Poles (IYCP). Proposed for 2008, this conference will bring together youth from a diverse set of backgrounds and nationalities to discuss the issues affecting the Polar Regions, their effects on a global scale and ways of addressing these issues. The conference will also serve to highlight ongoing IPY research, especially research being undertaken by young researchers, and provide a perennial framework for youth involvement in polar research and policies. The IYCP will run for three days in May 2008, attracting an international youth audience, as well as representatives from polar organizations, teachers, politicians, policy makers, the general public and media. The IYCP will be divided into three sections. Youth Roundtable Discussions will bring youth together to discuss issues affecting the Polar Regions and potential solutions to these. A Young Researchers Conference will provide the opportunity for young researchers working in the Polar Regions to present their work to an interdisciplinary audience. The Polar Fair will provide an interactive environment for youth to learn about the Polar Regions. The IYCP will be of great importance to the IPY because it will serve as the principle venue during the Polar Year where youth from many different disciplines, backgrounds and countries will

  20. Bone grafting via reamer-irrigator-aspirator for nonunion of open Gustilo-Anderson type III tibial fractures treated with multiplanar external fixator

    Directory of Open Access Journals (Sweden)

    Kusnezov Nicholas

    2017-01-01

    Full Text Available Introduction: The purpose of this investigation was to evaluate the outcomes following reamer-irrigator-aspirator (RIA autogenous bone grafting (ABG of high-grade open tibia fracture nonunions stabilized via multiplanar external fixation. Methods: We retrospectively reviewed all patients with Gustilo-Anderson type III open tibia fractures treated with multiplanar external fixation and who underwent RIA ABG for nonunion at our institutional Level 1 Trauma Center between 2008 and 2015. All patients between 15 and 65 years of age with a minimum of six-month follow-up were included. The primary outcomes of interest were achievement of union, time to union, and incidence of revision surgery. Complications and all-cause reoperation were recorded as secondary endpoints. Results: Fifteen patients met the inclusion criteria with a mean age of 41.1 ± 14.0 years. RIA ABG was harvested from the femur in all cases, with a mean volume of 34 ± 15 mL. At an average follow-up of 13.3 ± 6.8 months, all patients achieved union, including two who required repeat RIA ABG. One patient experienced a femoral shaft fracture four months following RIA that required intramedullary fixation. The average time to union was 6.0 ± 6.3 months. Twelve patients (80% went on to union within six months and 13 (86.7% within one year. Five patients experienced a total of six post-operative complications including three deep infections, one refracture through the nonunion site, and one gradual varus deformity. Two patients in this series required a subsequent RIA autografting procedure secondary to persistent nonunion despite initial RIA. Conclusion: We found that RIA ABG offered a reliable solution to nonunion of Gustilo-Anderson type III open tibial fractures treated with multiplanar external fixation, circumventing the need to change the method of fixation.

  1. Equilibrium properties of proximity effect

    International Nuclear Information System (INIS)

    Esteve, D.; Pothier, H.; Gueron, S.; Birge, N.O.; Devoret, M.

    1996-01-01

    The proximity effect in diffusive normal-superconducting (NS) nano-structures is described by the Usadel equations for the electron pair correlations. We show that these equations obey a variational principle with a potential which generalizes the Ginzburg-Landau energy functional. We discuss simple examples of NS circuits using this formalism. In order to test the theoretical predictions of the Usadel equations, we have measured the density of states as a function of energy on a long N wire in contact with a S wire at one end, at different distances from the NS interface. (authors)

  2. Equilibrium properties of proximity effect

    Energy Technology Data Exchange (ETDEWEB)

    Esteve, D.; Pothier, H.; Gueron, S.; Birge, N.O.; Devoret, M.

    1996-12-31

    The proximity effect in diffusive normal-superconducting (NS) nano-structures is described by the Usadel equations for the electron pair correlations. We show that these equations obey a variational principle with a potential which generalizes the Ginzburg-Landau energy functional. We discuss simple examples of NS circuits using this formalism. In order to test the theoretical predictions of the Usadel equations, we have measured the density of states as a function of energy on a long N wire in contact with a S wire at one end, at different distances from the NS interface. (authors). 12 refs.

  3. Pole-to-pole biogeography of surface and deep marine bacterial communities

    Science.gov (United States)

    Ghiglione, Jean-François; Galand, Pierre E.; Pommier, Thomas; Pedrós-Alió, Carlos; Maas, Elizabeth W.; Bakker, Kevin; Bertilson, Stefan; Kirchman, David L.; Lovejoy, Connie; Yager, Patricia L.; Murray, Alison E.

    2012-01-01

    The Antarctic and Arctic regions offer a unique opportunity to test factors shaping biogeography of marine microbial communities because these regions are geographically far apart, yet share similar selection pressures. Here, we report a comprehensive comparison of bacterioplankton diversity between polar oceans, using standardized methods for pyrosequencing the V6 region of the small subunit ribosomal (SSU) rRNA gene. Bacterial communities from lower latitude oceans were included, providing a global perspective. A clear difference between Southern and Arctic Ocean surface communities was evident, with 78% of operational taxonomic units (OTUs) unique to the Southern Ocean and 70% unique to the Arctic Ocean. Although polar ocean bacterial communities were more similar to each other than to lower latitude pelagic communities, analyses of depths, seasons, and coastal vs. open waters, the Southern and Arctic Ocean bacterioplankton communities consistently clustered separately from each other. Coastal surface Southern and Arctic Ocean communities were more dissimilar from their respective open ocean communities. In contrast, deep ocean communities differed less between poles and lower latitude deep waters and displayed different diversity patterns compared with the surface. In addition, estimated diversity (Chao1) for surface and deep communities did not correlate significantly with latitude or temperature. Our results suggest differences in environmental conditions at the poles and different selection mechanisms controlling surface and deep ocean community structure and diversity. Surface bacterioplankton may be subjected to more short-term, variable conditions, whereas deep communities appear to be structured by longer water-mass residence time and connectivity through ocean circulation. PMID:23045668

  4. Optimal pole shifting controller for interconnected power system

    International Nuclear Information System (INIS)

    Yousef, Ali M.; Kassem, Ahmed M.

    2011-01-01

    Research highlights: → Mathematical model represents a power system which consists of synchronous machine connected to infinite bus through transmission line. → Power system stabilizer was designed based on optimal pole shifting controller. → The system performances was tested through load disturbances at different operating conditions. → The system performance with the proposed optimal pole shifting controller is compared with the conventional pole placement controller. → The digital simulation results indicated that the proposed controller has a superior performance. -- Abstract: Power system stabilizer based on optimal pole shifting is proposed. An approach for shifting the real parts of the open-loop poles to any desired positions while preserving the imaginary parts is presented. In each step of this approach, it is required to solve a first-order or a second-order linear matrix Lyapunov equation for shifting one real pole or two complex conjugate poles, respectively. This presented method yields a solution, which is optimal with respect to a quadratic performance index. The attractive feature of this method is that it enables solutions of the complex problem to be easily found without solving any non-linear algebraic Riccati equation. The present power system stabilizer is based on Riccati equation approach. The control law depends on finding the feedback gain matrix, and then the control signal is synthesized by multiplying the state variables of the power system with determined gain matrix. The gain matrix is calculated one time only, and it works over wide range of operating conditions. To validate the power of the proposed PSS, a linearized model of a simple power system consisted of a single synchronous machine connected to infinite bus bar through transmission line is simulated. The studied power system is subjected to various operating points and power system parameters changes.

  5. Efficacy of the lithotripsy in treating lower pole renal stones.

    Science.gov (United States)

    Cui, Helen; Thomee, Eeke; Noble, Jeremy G; Reynard, John M; Turney, Benjamin W

    2013-06-01

    Use of extracorporeal lithotripsy is declining in North America and many European countries despite international guidelines advocating it as a first-line therapy. Traditionally, lithotripsy is thought to have poor efficacy at treating lower pole renal stones. We evaluated the success rates of lithotripsy for lower pole renal stones in our unit. 50 patients with lower pole kidney stones ≤15 mm treated between 3/5/11 and 19/4/12 were included in the study. Patients received lithotripsy on a fixed-site Storz Modulith SLX F2 lithotripter according to a standard protocol. Clinical success was defined as stone-free status or asymptomatic clinically insignificant residual fragments (CIRFs) ≤3 mm at radiological follow-up. The mean stone size was 7.8 mm. The majority of stones (66 %) were between 5 and 10 mm. 28 % of stones were between 10 and 15 mm. For solitary lower pole stones complete stone clearance was achieved in 63 %. Total stone clearance including those with CIRFs was achieved in 81 % of patients. As expected, for those with multiple lower pole stones the success rates were lower: complete clearance was observed in 39 % and combined clearance including those with CIRFs was 56 %. Overall, complete stone clearance was observed in 54 % of patients and clearance with CIRFs was achieved in 72 % of patients. Success rate could not be attributed to age, stone size or gender. Our outcome data for the treatment of lower pole renal stones (≤15 mm) compare favourably with the literature. With this level of stone clearance, a non-invasive, outpatient-based treatment like lithotripsy should remain the first-line treatment option for lower pole stones. Ureteroscopy must prove that it is significantly better either in terms of clinical outcome or patient satisfaction to justify replacing lithotripsy.

  6. Optimal pole shifting controller for interconnected power system

    Energy Technology Data Exchange (ETDEWEB)

    Yousef, Ali M., E-mail: drali_yousef@yahoo.co [Electrical Eng. Dept., Faculty of Engineering, Assiut University (Egypt); Kassem, Ahmed M., E-mail: kassem_ahmed53@hotmail.co [Control Technology Dep., Industrial Education College, Beni-Suef University (Egypt)

    2011-05-15

    Research highlights: {yields} Mathematical model represents a power system which consists of synchronous machine connected to infinite bus through transmission line. {yields} Power system stabilizer was designed based on optimal pole shifting controller. {yields} The system performances was tested through load disturbances at different operating conditions. {yields} The system performance with the proposed optimal pole shifting controller is compared with the conventional pole placement controller. {yields} The digital simulation results indicated that the proposed controller has a superior performance. -- Abstract: Power system stabilizer based on optimal pole shifting is proposed. An approach for shifting the real parts of the open-loop poles to any desired positions while preserving the imaginary parts is presented. In each step of this approach, it is required to solve a first-order or a second-order linear matrix Lyapunov equation for shifting one real pole or two complex conjugate poles, respectively. This presented method yields a solution, which is optimal with respect to a quadratic performance index. The attractive feature of this method is that it enables solutions of the complex problem to be easily found without solving any non-linear algebraic Riccati equation. The present power system stabilizer is based on Riccati equation approach. The control law depends on finding the feedback gain matrix, and then the control signal is synthesized by multiplying the state variables of the power system with determined gain matrix. The gain matrix is calculated one time only, and it works over wide range of operating conditions. To validate the power of the proposed PSS, a linearized model of a simple power system consisted of a single synchronous machine connected to infinite bus bar through transmission line is simulated. The studied power system is subjected to various operating points and power system parameters changes.

  7. Is the Clavicula Pro Humero Technique of Value for Reconstruction After Resection of the Proximal Humerus in Children?

    Science.gov (United States)

    Barbier, Dominique; De Billy, Benoît; Gicquel, Philippe; Bourelle, Sophie; Journeau, Pierre

    2017-10-01

    There are several options for reconstruction of proximal humerus resections after wide resection for malignant tumors in children. The clavicula pro humero technique is a biologic option that has been used in the past, but there are only scant case reports and small series that comment on the results of the procedure. Because the longevity of children mandates a reconstruction with potential longevity not likely to be achieved by other techniques, the clavicula pro humero technique may be a potential option in selected patients. (1) How successful is the clavicula pro humero procedure in achieving local tumor control? (2) What is the frequency of nonunion? (3) What are the complications of the procedure? (4) What scores do patients achieve (on the Musculoskeletal Tumor Society (MSTS) and the Toronto Extremity Salvage Score (TESS) after this procedure? Four university hospitals performed the clavicula pro humero technique in eight children aged 8 to 18 years between June 2006 and February 2014. During that period, general indications for this approach included all reconstructions of the proximal humerus for malignant tumors in children older than 8 years. All patients were followed for a mean of 40 months (range, 25-86 months); one patient was lost to followup before 2 years. The tumor resections removed the rotator cuff muscles in all patients, glenohumeral joint in five, and deltoid muscle in three. The median length of the bone defect after resection was 20 cm (range, 7-25 cm). It was reduced to 9 cm (range, 0-17 cm) or 27% (range, 0%-64%) of the total humerus length after clavicular rotation. Direct osteosynthesis (one patient), induced membrane technique (one patient), or vascularized fibular autograft (six patients) was used to complete the defect after rotation of the clavicle if necessary. Presence of union (defined as bone healing before 10 months, as assessed by disappearance of the osteotomy on AP and lateral view radiographs), and complications were

  8. Late Prosthetic Shoulder Hemiarthroplasty after Failed Management of Complex Proximal Humeral Fractures

    Directory of Open Access Journals (Sweden)

    A. Panagopoulos

    2013-01-01

    Full Text Available Background. The purpose of this study was to report our experience with shoulder hemiarthroplasty in the context of old trauma. Methods. 33 patients with failed treatment for a complex proximal humeral fracture underwent prosthetic hemiarthroplasty. There were 15 men and 18 women with a mean age of 58.1 years. The average period from initial treatment was 14.9 months. Sequelae included 11 malunions, 4 nonunions, 15 cases with avascular necrosis (AVN and 3 neglected posterior locked dislocations. Follow up investigation included radiological assessment and clinical evaluation using the Constant score and a visual analogue pain scale. Results. After a mean follow up of 82.5 months the median Constant score was 75.7 points, improved by 60% in comparison to preoperative values. Greater tuberosity displacement, large cuff tears and severe malunion were the factors most affected outcome. No cases of stem loosening or severe migration were noted. 60% of the patients were able to do activities up to shoulder level compared with 24% before reconstruction. Conclusions. Late shoulder hemiarthroplasty is technically difficult and the results are inferior to those reported for acute humeral head replacement, nonetheless remains a satisfactory reconstructive option when primary treatment fails.

  9. Development of a multi-pole magnetorheological brake

    International Nuclear Information System (INIS)

    Shiao, Yaojung; Nguyen, Quang-Anh

    2013-01-01

    This paper presents a new approach in the design and optimization of a novel multi-pole magnetorheological (MR) brake that employs magnetic flux more effectively on the surface of the rotor. MR brakes with conventional single ring-type electromagnetic poles have reached the limits of torque enhancement. One major reason is the limitation of the magnetic field strength within the active area of the MR fluid due to the geometric constraints of the coil. The multi-pole MR brake design features multiple electromagnetic poles surrounded by several coils. As a result, the active chaining areas for the MR fluid are greatly increased, and significant brake torque improvement is achieved. The coil structure, as a part of the stator, becomes flexible and customizable in terms of space usage for the winding and bobbin design. In addition, this brake offers extra options in its dimensions for torque enhancement because either the radial or the axial dimensions of the rotor can be increased. Magnetic circuit analysis was conducted to analyze the effects of the design parameters on the field torque. After that, simulations were done to find the optimal design under all major geometric constraints with a given power supply. The results show that the multi-pole MR brake provides a considerable braking torque increase while maintaining a compact and solid design. This is confirmation of its feasibility in actual braking applications. (paper)

  10. Avoidance of a Landau pole by flat contributions in QED

    Energy Technology Data Exchange (ETDEWEB)

    Klaczynski, Lutz, E-mail: lutz.klaczynski@gmx.de [Department of Physics, Humboldt University Berlin, 12489 Berlin (Germany); Kreimer, Dirk, E-mail: kreimer@mathematik.hu-berlin.de [Alexander von Humboldt Chair in Mathematical Physics, Humboldt University, Berlin 12489 (Germany)

    2014-05-15

    We consider massless Quantum Electrodynamics in the momentum scheme and carry forward an approach based on Dyson–Schwinger equations to approximate both the β-function and the renormalized photon self-energy (Yeats, 2011). Starting from the Callan–Symanzik equation, we derive a renormalization group (RG) recursion identity which implies a non-linear ODE for the anomalous dimension and extract a sufficient but not necessary criterion for the existence of a Landau pole. This criterion implies a necessary condition for QED to have no such pole. Solving the differential equation exactly for a toy model case, we integrate the corresponding RG equation for the running coupling and find that even though the β-function entails a Landau pole it exhibits a flat contribution capable of decreasing its growth, in other cases possibly to the extent that such a pole is avoided altogether. Finally, by applying the recursion identity, we compute the photon propagator and investigate the effect of flat contributions on both spacelike and timelike photons. -- Highlights: •We present an approach to approximate both the β-function and the photon self-energy. •We find a sufficient criterion for the self-energy to entail the existence of a Landau pole. •We study non-perturbative ‘flat’ contributions that emerge within the context of our approach. •We discuss a toy model and how it is affected by flat contributions.

  11. Choice of wood poles can reduce greenhouse gases

    Energy Technology Data Exchange (ETDEWEB)

    Sedjo, R. A.

    2002-07-01

    The first, second and third assessment reports on climate change of the Intergovernmental Panel on Climate Change (IPCC) are reviewed in an effort to highlight results of past studies on the total life cycle energy utilization of wood products compared with the use of substitute materials such as steel, concrete, bricks and aluminum. Without exception, all studies found that the total energy requirements associated with wood materials are substantially lower than those of other commonly substituted materials. For example, it has been clearly demonstrated that wooden poles are more environmentally benign than concrete or steel poles with regard to their energy utilization and their potential to contribute to atmospheric carbon dioxide emissions. An estimate to convert wood poles to steel poles showed that while the greenhouse gas emissions associated with pole conversion were modest compared to the national total, they were nevertheless a significant percentage of US annual emission (approximately 2.8 per cent of annual US total of 5.28 billion tons of carbon dioxide). These studies provide empirical confirmation of the concept that substitution of high energy-intensive materials for low-energy-using wood materials contributes substantially to the overall increase of carbon dioxide emissions through their overall higher energy requirements.

  12. Analysis of car’s frontal collision against pole

    Science.gov (United States)

    Ispas, N.; Nastasoiu, M.

    2017-10-01

    Reducing the effects of traffic accidents over the occupants is a major objective of collision attempts. Impacts between the car and the pole are very dangerous for the physical integrity of the car’s occupants. To minimalize the effects of such events on the passengers of a vehicle, a whole series of efforts by both designers and experienced engineers led to increasingly the vehicles safety. The main aim of these paper is to quantify the influences over the car passengers of loads involved by car against pole collisions using the same car model at different speeds. Also, this kind on occupant influences were study using a small car model. Other goal of the paper was the study of the cars stiffness in frontal collision against the pole. The paper’s experimental results were obtained by support of DSD, Dr. Steffan Datentechnik GmbH - Linz, Austria. The described tests were performed in full test facility of DSD Linz, in “Easter 2016 PC-Crash Seminar”. Cars accelerations, velocities, rotations angles after pole impact were registered and discussed. The novelty of the paper consists in studies referred for the same car model involved in car against pole collisions at different impact speeds. Paper’s conclusions can be future used for car safety improvement.

  13. Compact high-field superconducting quadrupole magnet with holmium poles

    Energy Technology Data Exchange (ETDEWEB)

    Barlow, D.B.; Kraus, R.H. Jr.; Lobb, C.T.; Menzel, M.T. (Los Alamos National Lab., NM (United States)); Walstrom, P.L. (Grumman Space Systems, Los Alamos, NM (United States))

    1992-03-15

    A compact high-field superconducting quadrupole magnet was designed and built with poles made of the rare-earth metal holmium. The magnet is intended for use in superconducting coupled-cavity linear accelerators where compact high-field quadrupoles are needed, but where the use of permanent magnets is ruled out because of trapped-flux losses. The magnet has a clear bore diameter of 1.8 cm, outside diameter of 11 cm, length of 11 cm, and pole tip length of 6 cm. The effect of using holmium, a material with a higher saturation field than iron, was investigated by replacing poles made of iron with identical poles made of holmium. The magnet was operated at a temperature of 4.2 K and reached a peak quadrupole field gradient of 355 T/m, a 10% increase over the same magnet with iron poles. This increase in performance is consistent with calculations based on B-H curves that were measured for holmium at 4.2 K. (orig.).

  14. Realities of proximity facility siting

    International Nuclear Information System (INIS)

    DeMott, D.L.

    1981-01-01

    Numerous commercial nuclear power plant sites have 2 to 3 reactors located together, and a group of Facilities with capabilities for fuel fabrication, a nuclear reactor, a storage area for spent fuel, and a maintenance area for contaminated equipment and radioactive waste storage are being designed and constructed in the US. The proximity of these facilities to each other provides that the ordinary flow of materials remain within a limited area. Interactions between the various facilities include shared resources such as communication, fire protection, security, medical services, transportation, water, electrical, personnel, emergency planning, transport of hazardous material between facilities, and common safety and radiological requirements between facilities. This paper will explore the advantages and disadvantages of multiple facilities at one site. Problem areas are identified, and recommendations for planning and coordination are discussed

  15. Longitudinal analysis of osteogenic and angiogenic signaling factors in healing models mimicking atrophic and hypertrophic non-unions in rats.

    Directory of Open Access Journals (Sweden)

    Susann Minkwitz

    Full Text Available Impaired bone healing can have devastating consequences for the patient. Clinically relevant animal models are necessary to understand the pathology of impaired bone healing. In this study, two impaired healing models, a hypertrophic and an atrophic non-union, were compared to physiological bone healing in rats. The aim was to provide detailed information about differences in gene expression, vascularization and histology during the healing process. The change from a closed fracture (healing control group to an open osteotomy (hypertrophy group led to prolonged healing with reduced mineralized bridging after 42 days. RT-PCR data revealed higher gene expression of most tested osteogenic and angiogenic factors in the hypertrophy group at day 14. After 42 days a significant reduction of gene expression was seen for Bmp4 and Bambi in this group. The inhibition of angiogenesis by Fumagillin (atrophy group decreased the formation of new blood vessels and led to a non-healing situation with diminished chondrogenesis. RT-PCR results showed an attempt towards overcoming the early perturbance by significant up regulation of the angiogenic regulators Vegfa, Angiopoietin 2 and Fgf1 at day 7 and a further continuous increase of Fgf1, -2 and Angiopoietin 2 over time. However µCT angiograms showed incomplete recovery after 42 days. Furthermore, lower expression values were detected for the Bmps at day 14 and 21. The Bmp antagonists Dan and Twsg1 tended to be higher expressed in the atrophy group at day 42. In conclusion, the investigated animal models are suitable models to mimic human fracture healing complications and can be used for longitudinal studies. Analyzing osteogenic and angiogenic signaling patterns, clear changes in expression were identified between these three healing models, revealing the importance of a coordinated interplay of different factors to allow successful bone healing.

  16. The treatment of scaphoid nonunion using the Ilizarov fixator without bone graft, a study of 18 cases

    Directory of Open Access Journals (Sweden)

    Bumbaširević Marko

    2011-11-01

    Full Text Available Abstract Objectives Evaluating the safety and efficacy of the Ilizarov fine-wire compression/distraction technique in the treatment of scaphoid nonunion (SNU, without the use of bone graft. Design A retrospective review of 18 consecutive patients in one centre. Patients and Methods 18 patients; 17 males; 1 female, with a mean SNU duration of 13.9 months. Patients with carpal instability, humpback deformity, carpal collapse, avascular necrosis or marked degenerative change, were excluded. Following frame application the treatment consisted of three stages: the frame was distracted 1 mm per day until radiographs showed a 2-3 mm opening at the SNU site (mean 10 days; the SNU site was then compressed for 5 days, at a rate of 1 mm per day, with the wrist in 15 degrees of flexion and 15 degrees of radial deviation; the third stage involved immobilization with the Ilizarov fixator for 6 weeks. The technique is detailed herein. Results Radiographic (CT and clinical bony union was achieved in all 18 patients after a mean of 89 days (70-130 days. Mean modified Mayo wrist scores improved from 21 to 86 at a mean follow-up of 37 months (24-72 months, with good/excellent results in 14 patients. All patients returned to their pre-injury occupations and levels of activity at a mean of 117 days. Three patients suffered superficial K-wire infections, which resolved with oral antibiotics. Conclusions In these selected patients this technique safely achieved bony union without the need to open the SNU site and without the use of bone graft.

  17. Russians, Jews, and Poles: Russification and Antisemitism 1881-1914

    Directory of Open Access Journals (Sweden)

    Theodor R. Weeks

    2012-07-01

    Full Text Available Relations between Poles and Jews deteriorated significantly in the three decades leading up to World War I. Many reasons for this phenomenon can be given, for example: economic competition, a general atmosphere of acute nationalism, increased migration, perceived threats to traditional forms of life and religion. Exacerbating all of these factors, however, was the fact of Polish statelessness and the extreme sensitivity of Poles to perceived threats to their culture and nation. In particular within the Russian Empire, Poles perceived the very future of their nation at risk. In such circumstances the continued existence of Jewish cultural difference combined with the development of specifically Jewish forms of national awakening (e.g., the Bund and Zionism were understood by many in Polish society as ingratitude and collaboration with the Russian occupier

  18. PLANNING THE QUALITY OF LIFE FOR TIMISOARA GROWTH POLE

    Directory of Open Access Journals (Sweden)

    Cătălina-Livia POPA

    2014-06-01

    Full Text Available This paper aims to show that planning the quality of life at local level through economic development can be a new approach for policy makers and community in improving quality of life. In this purpose, the Quality Function Deployment (QFD model will be use to planning the quality of life and to identify the main directions of economic development to support improving the quality of life at the level of Timisoara Growth Pole from Romania. The dimensions of quality of life are analyzed starting from the point of view of inhabitants. The results include a new approach in which the dimensions of quality of life are the key element that orients economic development in order to improve the quality of life of human being. The case study results refer to the main elements of quality of life at Timisoara Growth Pole and the relevant directions of economic development to improve the quality of life for Timisoara Growth Pole.

  19. Third Pole Environment (TPE): a new frontier for interdisciplinary research

    Science.gov (United States)

    Liu, Z.; Yao, T.; Thompson, L. G.; Mosbrugger, V.; Zhang, F.; Ma, Y.; Yang, X.; Wang, W.; Joswiak, D.; Liu, X.; Devkota, L. P.; Tayal, S.; Luo, T.

    2013-12-01

    The Tibetan Plateau and surrounding mountain ranges, referred to by scientists as the Third Pole (TP), represent one of the largest ice masses of the Earth. The region is one of the most sensitive areas responding to global climate change due to its high altitude and the presence of permafrost and glaciers. The near 100,000 km2 of glaciers ensure the permanent flow of major rivers in this region and provide water to 1.4 billion people in Asia. Thus, environmental changes taking place on the TP significantly influences social and economic development of countries in this region such as China, India, Nepal, Tajikistan, Pakistan, Afghanistan and Bhutan. With an average elevation higher than 4,000 metres above sea level, the Third Pole is characterized by complex interactions of atmospheric, cryospheric, hydrological, geological and environmental processes that bear special significance for the Earth's biodiversity, climate and water cycles. For a comprehensive understanding of the environment of the TP and its implications on the development of the region, we need to integrate different disciplines under a them of 'water-ice-air-ecosystem -human' interactions and reveal environmental change processes and mechanisms on the TP and their influences on and regional responses to global changes, and thus to serve for enhancement of human adaptation to the changing environment. Like Antarctica and the Arctic, the Third Pole region is drawing increased attention of the international academic community. A series of observations and monitoring programs in the Third Pole region has been widely implemented. However, data necessary to precisely assess the environmental, societal and economic changes caused by alterations in the Third Pole dynamics are either lacking or insufficient. The Third Pole Environment (TPE) program is thus established as a comprehensive and coordinated international research, monitoring and capacity building initiative, with goals to address the influence

  20. Magnetic transmission gear finite element simulation with iron pole hysteresis

    Science.gov (United States)

    Filippini, Mattia; Alotto, Piergiorgio; Glehn, Gregor; Hameyer, Kay

    2018-04-01

    Ferromagnetic poles in a magnetic transmission gear require particular attention during their design process. Usually, during the numerical simulation of these devices the effects of hysteresis for loss estimation are neglected and considered only during post-processing calculations. Since the literature lacks hysteresis models, this paper adopts a homogenized hysteretic model able to include eddy current and hysteresis losses in 2D laminated materials for iron poles. In this article the results related to the hysteresis in a magnetic gear are presented and compared to the non-hysteretic approach.

  1. Revised paleomagnetic pole for the Sonoma Volcanics, California

    Science.gov (United States)

    Mankinen, E.A.

    1989-01-01

    Paleomagnetic sampling of the Miocene and Pliocene Sonoma Volcanics, northern California, was undertaken to supplement an earlier collection. Data from 25 cooling units yield positive fold and reversal tests, and a paleomagnetic pole located at 80.2??N., 069.2??E., with ??95 = 6.8??. This paleopole is significantly displaced (9.6?? ?? 5.3?? of latitude) to the farside of the geographic pole. A highly elliptical distribution of the data in both direction and VGP space indicates that incomplete averaging of geomagnetic secular variation is a more likely explanation for this anomaly than is northward translation of the volcanic field. -Author

  2. Induction Motor with Switchable Number of Poles and Toroidal Winding

    Directory of Open Access Journals (Sweden)

    MUNTEANU, A.

    2011-05-01

    Full Text Available This paper presents a study of an induction motor provided with toroidal stator winding. The ring-type coils offer a higher versatility in obtaining a different number of pole pairs by means of delta/star and series/parallel connections respectively. As consequence, the developed torque can vary within large limits and the motor can be utilized for applications that require, for example, high load torque values for a short time. The study involves experimental tests and FEM simulation for an induction machine with three configurations of pole pairs. The conclusions attest the superiority of the toroidal winding for certain applications such as electric vehicles or lifting machines.

  3. Poles Living in Ireland and their Quality of Life

    Directory of Open Access Journals (Sweden)

    Agnieszka NOLKA

    2009-05-01

    Full Text Available The economic growth of Ireland resulted in a significant number of Poles migrating to Ireland following the EU enlargement in 2004. The article explores the quality of life of Poles living in Ireland. Using data from a preliminary survey conducted in 2006, several dimensions of living conditions are analysed, including interpersonal relations, material security, health and healthcare. The study shows that evaluations of almost all aspects of quality of life improved, apart from components such as healthcare and the ability to acquire help from social organisations. Also interpersonal relations, contrary to the initial assumption, were enhanced by migration to Ireland.

  4. Nontraumatic osteonecrosis of the distal pole of the scaphoid

    Directory of Open Access Journals (Sweden)

    Bhavuk Garg

    2011-01-01

    Full Text Available Post traumatic osteonecrosis of distal pole of scaphoid is very rare. We present a case of 34 years old male, drill operator by occupation with nontraumatic osteonecrosis of distal pole of the scaphoid. The patient was managed conservatively and was kept under regular follow-up every three months. The patient was also asked to change his profession. Two years later, the patient had no pain and had mild restriction of wrist movements (less than 15 degrees in either direction. The radiographs revealed normal density of the scaphoid suggesting revascularization.

  5. Safety study: is there a pathologic IGF-1, PDGF and TGF-ß cytokine expression caused by adjunct BMP-7 in tibial and femoral non-union therapy?

    Directory of Open Access Journals (Sweden)

    Fischer C

    2018-04-01

    Full Text Available Christian Fischer,1 Christian Reiner,2 Gerhard Schmidmaier,1 Julian Doll,1 Christopher Child,3 Paul Alfred Grützner,4 Bahram Biglari,4 Sonja Boxriker,5 Arash Moghaddam5 1Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, HTRG – Heidelberg Trauma Research Group, Heidelberg University Hospital, Heidelberg, Germany; 2Department of Trauma and Orthopedic Surgery, Paracelsus Medical University, Nuremberg Hospital South, Nuremberg, Germany; 3Department of Trauma Surgery, University Hospital Zurich, Zurich, Switzerland; 4Trauma and Orthopedics, BG Trauma Center Ludwigshafen, Ludwigshafen, Germany; 5Center of Orthopedics, Trauma Surgery and Sport Medicine, ATORG Aschaffenburg-Alzenau, Aschaffenburg, Germany Background: In this prospective safety study, we investigated if the characteristic cytokine expression during bone regeneration is manipulated by the local application of bone morphogenetic protein-7 (BMP-7 in non-union surgery. Therefore, the levels of insulin like growth factor 1 (IGF-1, platelet-derived growth factor AB (PDGF-AB and transforming growth factor beta (TGF-β were compared between patients with the gold standard use of autologous bone graft (ABG and those with additional application of BMP-7 as part of the diamond concept.Patients and methods: Between 2009 and 2014, of the 153 patients with tibial and femoral non-unions, a matched pair analysis was performed to compare the serological cytokine expressions. Blood samples were collected preoperatively, 1, 2 and 6 weeks as well as 3 and 6 months after non-union surgery. Matching criteria were smoking status, fracture location, gender, age and body mass index (BMI. Patients in G1 (n=10 were treated with ABG and local BMP-7 while their matching partners in G2 (n=10 received ABG only. The routine clinical and radiologic follow-up was 1 year.Results: Although the IGF-1 quantification in G2 showed higher pre- and postoperative values compared to G1 (p<0.05, the courses of both

  6. Staged minimally invasive plate osteosynthesis of proximal tibial fractures with acute compartment syndrome.

    Science.gov (United States)

    Kim, Joon-Woo; Oh, Chang-Wug; Oh, Jong-Keon; Kyung, Hee-Soo; Park, Kyeong-Hyeon; Kim, Hee-June; Jung, Jae-Wook; Jung, Young-Soo

    2017-06-01

    High-energy proximal tibial fractures often accompany compartment syndrome and are usually treated by fasciotomy with external fixation followed by secondary plating. However, the initial soft tissue injury may affect bony union, the fasciotomy incision or external fixator pin sites may lead to postoperative wound infections, and the staged procedure itself may adversely affect lower limb function. We assess the results of staged minimally invasive plate osteosynthesis (MIPO) for proximal tibial fractures with acute compartment syndrome. Twenty-eight patients with proximal tibial fractures accompanied by acute compartment syndrome who underwent staged MIPO and had a minimum of 12 months follow-up were enrolled. According to the AO/OTA classification, 6 were 41-A, 15 were 41-C, 2 were 42-A and 5 were 42-C fractures; this included 6 cases of open fractures. Immediate fasciotomy was performed once compartment syndrome was diagnosed and stabilization of the fracture followed using external fixation. After the soft tissue condition normalized, internal conversion with MIPO was done on an average of 37 days (range, 9-158) after index trauma. At the time of internal conversion, the external fixator pin site grades were 0 in 3 cases, 1 in 12 cases, 2 in 10 cases and 3 in 3 cases, as described by Dahl. Radiographic assessment of bony union and alignment and a functional assessment using the Knee Society Score and American Orthopedic Foot and Ankle Society (AOFAS) score were carried out. Twenty-six cases achieved primary bony union at an average of 18.5 weeks. Two cases of nonunion healed after autogenous bone grafting. The mean Knee Society Score and the AOFAS score were 95 and 95.3 respectively, at last follow-up. Complications included 1 case of osteomyelitis in a patient with a grade IIIC open fracture and 1 case of malunion caused by delayed MIPO due to poor wound conditions. Duration of external fixation and the external fixator pin site grade were not related to the

  7. comparative proximate composition and antioxidant vitamins

    African Journals Online (AJOL)

    DR. AMINU

    Keywords: Comparative, proximate composition, antioxidant vitamins, honey. INTRODUCTION ... solution of inverted sugars and complex mixture of other saccharides ... enzymatic browning in apple slices and grape juice. (Khan, 1985).

  8. Proximate, Mineral and Phytochemical Composition of Dioscorea ...

    African Journals Online (AJOL)

    ADOWIE PERE

    Keywords: Dioscorea dumetorum, proximate composition, mineral analysis, phytochemical screening ... were analyzed using atomic absorption ... determined using a Hack Dr/200 Spectrophotometer. ... Lead Acetate. +. +. + .... cosmetics.

  9. Proximate composition and antinutrient content of pumpkin ...

    African Journals Online (AJOL)

    Proximate composition and antinutrient content of pumpkin ( Cucurbita pepo ) and sorghum ( Sorghum bicolor ) flour blends fermented with Lactobacillus plantarum , Aspergillus niger and Bacillus subtilis.

  10. Cell-based Assay System for Predicting Bone Regeneration in Patient Affected by Aseptic Nonunion and Treated with Platelet Rich Fibrin.

    Science.gov (United States)

    Perut, Francesca; Dallari, Dante; Rani, Nicola; Baldini, Nicola; Granchi, Donatella

    Regenerative strategies based on the use of platelet concentrates as an autologous source of growth factors (GF) has been proposed to promote the healing of long bone nonunions. However, the relatively high failure rate stimulates interest in growing knowledge and developing solutions to obtain the best results from the regenerative approach. In this study we evaluated whether a cell-based assay system could be able to recognize patients who will benefit or not from the use of autologous platelet preparations. The autologous serum was used in culture medium to promote the osteogenic differentiation of normal bone-marrow stromal cells (BMSC). Blood samples were collected from 16 patients affected by aseptic long bone nonunion who were candidates to the treatment with autologous platelet-rich fibrin. The osteoinductive effect was detected by measuring the BMSC proliferation, the mineralization activity, and the expression of bone-related genes. Serum level of basic fibroblast growth factor (bFGF) was considered as a representative marker of the delivery of osteogenic GFs from platelets. Laboratory results were related to the characteristics of the disease before the treatment and to the outcome at 12 months. Serum samples from "good responders" showed significantly higher levels of bFGF and were able to induce a significantly higher proliferation of BMSC, while no significant differences were observed in terms of osteoblast differentiation. BMSC-based assay could be a useful tool to recognize patients who have a low probability to benefit from the use of autologous platelet concentrate to promote the healing of long bone nonunion.

  11. Particles as S-matrix poles: hadron democracy

    International Nuclear Information System (INIS)

    Chew, G.F.

    1989-01-01

    The connection between two theoretical ideas of the 1950s is traced in this article, namely that hadrons are nonfundamental, ''composite'' particles and that all physically observable particles correspond to singularities of an analytic scattering matrix. The S matrix theory developed by Werner Heisenberg in the early forties now incorporated the concepts of unitarity, invariance, analyticity and causality. The meson-exchange force meant that poles must be present in nucleon-nuclear and pion-nucleon scattering as predicted by dispersion relations. Experimental work in accessible regions determined pole residues. Pole residue became associated with force strength and pole position with particle mass. In 1959, the author discovered the so-called ''bootstrap'' theory the rho meson as a force generates a rho particle. By the end of the 1950s it was clear that all hadrons had equal status, each being bound states of other hadrons, sustained by hadron exchange forces and that hadrons are self-generated by an S-matrix bootstrap mechanism that determines all their properties. (UK)

  12. Determination of pole orientations and shapes of asteroids

    International Nuclear Information System (INIS)

    Magnusson, P.; Barucci, M.A.; Drummond, J.D.; Lumme, K.; Surdej, J.

    1989-01-01

    The principles of asteroid lightcurve inversion and the information available from photometry are reviewed. General tools as well as specific techniques for shape and pole determinations are summarized and their advantages and shortcomings are discussed. The authors present the results obtained so far in this very active field and discuss their significance in the general context of asteroid research and planetary formation

  13. Separable pole expansions in four-nucleon bound state calculations

    International Nuclear Information System (INIS)

    Sofianos, S.A.; Fiedeldey, H.; Haberzettl, H.; Sandhas, W.

    1982-04-01

    We compare the utility of the Generalized Unitary Pole Expansion (GUPE) and the Energy-Dependent Pole Expansion (EDPE) for the three-body subsystem amplitudes in four-body state calculations for a variety of separable and local nucleon-nucleon interactions. It is found that, with the EDPE, the four-body binding energy is well reproduced with only two terms each for the (2+2)- and the (3+1)-subsystem, respectively, while the GUPE requires three terms for the (3+1)-channel and four terms for the (2+2)-channel. We thus conclude that pole dominance is of greater importance for the GUPE than for EDPE, which works equally well for both types of subsystems. It is found that both methods, in particular the EDPE, converge more rapidly with increasing repulsion in the two-body interaction, i.e. the more realistic the interaction becomes. Both expansions require similar computing times for a converged calculation and are about 15-20 times faster than the widely used Hilbert-Schmidt Expansion (HSE). The respective merits of the two pole expansions are discussed and compared with the HSE. (orig.)

  14. Biomechanical pole and leg characteristics during uphill diagonal roller skiing.

    Science.gov (United States)

    Lindinger, Stefan Josef; Göpfert, Caroline; Stöggl, Thomas; Müller, Erich; Holmberg, Hans-Christer

    2009-11-01

    Diagonal skiing as a major classical technique has hardly been investigated over the last two decades, although technique and racing velocities have developed substantially. The aims of the present study were to 1) analyse pole and leg kinetics and kinematics during submaximal uphill diagonal roller skiing and 2) identify biomechanical factors related to performance. Twelve elite skiers performed a time to exhaustion (performance) test on a treadmill. Joint kinematics and pole/plantar forces were recorded separately during diagonal roller skiing (9 degrees; 11 km/h). Performance was correlated to cycle length (r = 0.77; P Push-off demonstrated performance correlations for impulse of leg force (r = 0.84), relative duration (r= -0.76) and knee flexion (r = 0.73) and extension ROM (r = 0.74). Relative time to peak pole force was associated with performance (r = 0.73). In summary, diagonal roller skiing performance was linked to 1) longer cycle length, 2) greater impulse of force during a shorter push-off with larger flexion/extension ROMs in leg joints, 3) longer leg swing, and 4) later peak pole force, demonstrating the major key characteristics to be emphasised in training.

  15. Spectroscopic Binaries near the North Galactic Pole Paper 15: HD ...

    Indian Academy of Sciences (India)

    tribpo

    Galactic Pole field he treated HD 106947 as if nothing were already known ... By good fortune a Palomar radial-velocity observing run in late 1986 fell near to a .... obvious to the naked eye as a grouping of fifth- and sixth-magnitude stars in an.

  16. In-situ poling and structurization of piezoelectric particulate composites.

    Science.gov (United States)

    Khanbareh, H; van der Zwaag, S; Groen, W A

    2017-11-01

    Composites of lead zirconate titanate particles in an epoxy matrix are prepared in the form of 0-3 and quasi 1-3 with different ceramic volume contents from 10% to 50%. Two different processing routes are tested. Firstly a conventional dielectrophoretic structuring is used to induce a chain-like particle configuration, followed by curing the matrix and poling at a high temperature and under a high voltage. Secondly a simultaneous combination of dielectrophoresis and poling is applied at room temperature while the polymer is in the liquid state followed by subsequent curing. This new processing route is practiced in an uncured thermoset system while the polymer matrix still possess a relatively high electrical conductivity. Composites with different degrees of alignment are produced by altering the magnitude of the applied electric field. A significant improvement in piezoelectric properties of quasi 1-3 composites can be achieved by a combination of dielectrophoretic alignment of the ceramic particles and poling process. It has been observed that the degree of structuring as well as the functional properties of the in-situ structured and poled composites enhance significantly compared to those of the conventionally manufactured structured composites. Improving the alignment quality enhances the piezoelectric properties of the particulate composites.

  17. Finite element analysis of boron diffusion in wooden Poles

    DEFF Research Database (Denmark)

    Krabbenhøft, Kristian; Hoffmeyer, Preben; Bechgaard, Carl

    2004-01-01

    The problem of describing the migration of dissolved boron in wood is treated with special reference to the commonly used remedial treatment of wooden poles. The governing equations are derived and discussed together with some of the material parameters required. The equations are solved...

  18. Simple Regge pole model for Compton scattering of protons

    International Nuclear Information System (INIS)

    Saleem, M.; Fazal-e-Aleem

    1978-01-01

    It is shown that by a phenomenological choice of the residue functions, the differential cross section for ν p → ν p, including the very recent measurements up to - t=4.3 (GeV/c) 2 , can be explained at all measured energies greater than 2 GeV with simple Regge pole model

  19. Evidence for differentiation of cell wall poles in Bacillus subtilis

    International Nuclear Information System (INIS)

    Sonnenfeld, E.M.

    1985-01-01

    Previous data have suggested that the chromosome of Bacillus subtilis was found to the cell surface at polar regions. A significant corollary of DNA attachment to cell poles is the role of the cell wall in chromosome segregation. This project was mainly concerned with visualizing the DNA-cell wall association through autoradiography. The origin and terminus of replication were labelled with ( 3 H)-thymidine using a temperature-sensitive DNA initiation mutant. It was found that most of the radioactivity was associated with cell poles. Ultrastructural analyses of cell walls stained with dilute cationized ferritin showed that the polar area contained a site of dense electronegativity. It is not immediately apparent why cell wall poles would contain an area with a high concentration of negative charge. This finding may be related to the cell pole functioning as the site of chromosome attachment. An additional observation encountered in this study was that cell wall exhibited asymmetry with regard to negative charge, the outside surface being more electronegative than the inside. A significant consequence of this finding is that both teichoic acid and muramyl peptides are situated perpendicularly to the cell surface. This favored arrangement may facilitate cell separation during the division process due to opposition of like charges at septa. The results of this work provide further convincing evidence that the cell wall of B. subtilis is differentiated

  20. Kick, Glide, Pole! Cross-Country Skiing Fun (Part II)

    Science.gov (United States)

    Duoos, Bridget A.

    2012-01-01

    Part I of Kick, Glide, Pole! Cross-Country Skiing Fun, which was published in last issue, discussed how to select cross-country ski equipment, dress for the activity and the biomechanics of the diagonal stride. Part II focuses on teaching the diagonal stride technique and begins with a progression of indoor activities. Incorporating this fun,…

  1. ENPA endine juht seisukohti muutnud pole / Hendrik Vosman

    Index Scriptorium Estoniae

    Vosman, Hendrik

    2008-01-01

    Eelmisel aastal Eestit vähemuste diskrimineerimises süüdistanud Euroopa Nõukogu Parlamentaarse Assamblee endine esimees Rene van der Linden pole oma seisukohta muutnud ning usub endiselt, et tema jutt inimõiguste rikkumiste kohta Eestis peab paika. Vt. samas: Van der Linden

  2. An estimate on the purely imaginary poles of scattering matrix

    International Nuclear Information System (INIS)

    Bozhkov, Y.D.

    1988-12-01

    In this work we obtain two estimates (upper and lower) on the number of purely imaginary poles of the scattering matrix for the wave equation in the exterior of a compact smooth obstacle in R n , n ≥ 3 odd. The method of Lax and Phillips is used. (author). 5 refs

  3. Diplodia natalensis , Pole Evans: a causal agent of citrus gummosis ...

    African Journals Online (AJOL)

    Isolations were made from the barks of gummosis-infected citrus trees from orchards of the University of Ghana Agricultural Research Station at Kade. The isolation media used were 1.5% water agar, 1.5% water agar + nystatin and 1.5% water agar + benomyl. Four isolates including Diplodia natalensis Pole Evans, ...

  4. A variable-mode stator consequent pole memory machine

    Science.gov (United States)

    Yang, Hui; Lyu, Shukang; Lin, Heyun; Zhu, Z. Q.

    2018-05-01

    In this paper, a variable-mode concept is proposed for the speed range extension of a stator-consequent-pole memory machine (SCPMM). An integrated permanent magnet (PM) and electrically excited control scheme is utilized to simplify the flux-weakening control instead of relatively complicated continuous PM magnetization control. Due to the nature of memory machine, the magnetization state of low coercive force (LCF) magnets can be easily changed by applying either a positive or negative current pulse. Therefore, the number of PM poles may be changed to satisfy the specific performance requirement under different speed ranges, i.e. the machine with all PM poles can offer high torque output while that with half PM poles provides wide constant power range. In addition, the SCPMM with non-magnetized PMs can be considered as a dual-three phase electrically excited reluctance machine, which can be fed by an open-winding based dual inverters that provide direct current (DC) bias excitation to further extend the speed range. The effectiveness of the proposed variable-mode operation for extending its operating region and improving the system reliability is verified by both finite element analysis (FEA) and experiments.

  5. Liz Taylor : minu van Gogh pole natsidele kuulunud

    Index Scriptorium Estoniae

    2004-01-01

    Elizabeth Taylor palus kohtult otsust, et talle kuuluvat 15 miljonit dollarit maksvat Vincent van Goghi maali "Vaade Saint-Remy varjupaigale" pole natsid Margarete Mauthneri juudiperekonna käest vägivaldselt ära võtnud. E. Taylori isa ostis maali 1963. a. Londonis oksjonilt

  6. Carrier Phase GPS Navigation to the North Pole

    Science.gov (United States)

    Moore, T.; Roberts, G. W.

    Over the last few years, on-the-fly integer ambiguity resolution for GPS has proven to be successful over short baselines (500 km. New techniques have been developed at the University of Nottingham to allow very long baseline integer ambiguity resolution, on-the-fly. A major problem with the use of carrier phase data is that posed by cycle slips. A technique for detecting and correcting cycle slips has been developed, and its use is discussed in this paper. The new technique has been proven through a series of trials, one of which included two flights to the North Pole, performing centimetric level positioning all the way to the pole. For many years, the GD Aero-Systems Course of the Air Warfare Centre based at RAF Cranwell executed a series of equipment flight trials to the North Pole, called the ARIES Flights. In May 1996, the authors were fortunate to take part in both flights, via Iceland and Greenland, to the North Pole. Based on reference stations at Thule Air Base, integer ambiguity resolution was accomplished, on-the-fly, and centimetric level navigation maintained throughout the flights. Earlier trials detailed in the paper demonstrate that the technique can resolve integer ambiguities on-the-fly within a few seconds over a baseline length of approximately 134 km, resulting in an accuracy of 12 cm. The majority of the residual error source for this being the ionosphere.

  7. Cross-poling textures in a lead zirconate titanate piezoelectric material

    International Nuclear Information System (INIS)

    Wan, Shan; Bowman, Keith J.

    2000-01-01

    Tetragonal ferroelectric materials are polarized to induce the anisotropy necessary for the piezoelectric effect. This poling of the material is inherently an orientation process. Pole figure texture measurements of poling and cross-poling in a lead zirconate titanate Navy VI material show domain motion. The resulting axisymmetric and three-dimensional textures demonstrate the contribution of 90 degree sign domain motion to piezoelectricity. Cross-poling results in strong orientations with lower applied fields than in the initial poling steps. (c) 2000 Materials Research Society

  8. Plotter of pole figure using data from x-ray diffraction

    International Nuclear Information System (INIS)

    Lima, A.F.

    1990-01-01

    Any polycrystalline aggregate normally has a preferred crystallographic orientation, or texture which depends on its thermal and or mechanical history. Preferred orientation is best described by means of a pole figure. A pole figure is a stereographic projection which shows the variation in pole density with pole orientation, for a selected set of crystal planes. In this work, computer programs was developed to plot pole figures. The corrected intensities are calculated and directly transmitted to the plotter. The different intensities levels are represented by different colors in the pole figure. (author)

  9. The practice of pole dance as a leisure activity in Denmark

    DEFF Research Database (Denmark)

    Jensen, Andorra Lynn

    2015-01-01

    The aim of this study is to explore the how pole dance is practiced as a form of leisure activity in Denmark. The methodical approach is qualitative and inspired by ethnography. I have conducted a field study where I have observed and participated in the pole dance culture in Copenhagen from May ...... addresses the difference between a focus on dance and a focus on tricks in pole dancing as well as it examines the different opinions pole studio owners have concerning ‘sexiness’ in pole dance and how this affects the way pole dance is practiced....

  10. Transverse and Longitudinal proximity effect

    Science.gov (United States)

    Jalan, Pryianka; Chand, Hum; Srianand, Raghunathan

    2018-04-01

    With close pairs (˜1.5arcmin) of quasars (QSOs), absorption in the spectra of a background quasar in the vicinity of a foreground quasar can be used to study the environment of the latter quasar at kpc-Mpc scales. For this we used a sample of 205 quasar pairs from the Sloan Digital Sky-Survey Data Release 12 (SDSS DR12) in the redshift range of 2.5 to 3.5 by studying their H I Ly-α absorption. We study the environment of QSOs both in the longitudinal as well as in the transverse direction by carrying out a statistical comparison of the Ly-α absorption lines in the quasar vicinity to that of the absorption lines caused by the inter-galactic medium (IGM). This comparison was done with IGM, matched in absorption redshift and signal-to-noise ratio (SNR) to that of the proximity region. In contrast to the measurements along the line-of-sight, the regions transverse to the quasars exhibit enhanced H I Ly-α absorption. This discrepancy can either be interpreted as due to an anisotropic emission from the quasars or as a consequence of their finite lifetime.

  11. Inferior patellar pole fragmentation in children: just a normal variant?

    Energy Technology Data Exchange (ETDEWEB)

    Kan, J.H.; Vogelius, Esben S.; Orth, Robert C.; Guillerman, R.P.; Jadhav, Siddharth P. [Texas Children' s Hospital, E.B. Singleton Pediatric Radiology, Houston, TX (United States)

    2015-06-15

    Fragmentary ossification of the inferior patella is often dismissed as a normal variant in children younger than 10 years of age. The purpose of this study was to determine whether fragmentary inferior patellar pole ossification is a normal variant or is associated with symptoms or signs of pathology using MRI and clinical exam findings as reference. A retrospective review was performed on 150 patients ages 5-10 years who underwent 164 knee radiography and MRI exams (45.1% male, mean age: 7.8 years). The presence or absence of inferior patellar pole fragmentation on radiography was correlated with the presence or absence of edema-like signal on MR images. Clinical notes were reviewed for the presence of symptoms or signs referable to the inferior patellar pole. These data were compared with a 1:1 age- and sex-matched control group without inferior pole fragmentation. Statistical analysis was performed using two-tailed t-tests. Forty of 164 (24.4%) knee radiographs showed fragmentary ossification of the inferior patella. Of these 40 knees, 62.5% (25/40) had edema-like signal of the inferior patellar bone marrow compared with 7.5% (3/40) of controls (P = 0.035). Patients with fragmentary ossification at the inferior patella had a significantly higher incidence of documented focal inferior patellar pain compared with controls (20% vs. 2.5%, P = 0.015). Inferior patellar pole fragmentation in children 5 to 10 years of age may be associated with localized symptoms and bone marrow edema-like signal and should not be routinely dismissed as a normal variant of ossification. (orig.)

  12. Proximal Participation: A Pathway into Work

    Science.gov (United States)

    Chan, Selena

    2013-01-01

    In a longitudinal case study of apprentices, the term proximal participation was coined to describe the entry process of young people, with unclear career destinations, into the trade of baking. This article unravels the significance of proximal participation in the decision-making processes of young people who enter a trade through initial…

  13. Bimalleolar ankle fracture with proximal fibular fracture

    NARCIS (Netherlands)

    Colenbrander, R. J.; Struijs, P. A. A.; Ultee, J. M.

    2005-01-01

    A 56-year-old female patient suffered a bimalleolar ankle fracture with an additional proximal fibular fracture. This is an unusual fracture type, seldom reported in literature. It was operatively treated by open reduction and internal fixation of the lateral malleolar fracture. The proximal fibular

  14. Consequences of Avulsion Fracture of the Proximal Phalanx Caused by a Technical Failure of Hallux Valgus Surgery.

    Science.gov (United States)

    Park, Young Uk; Lee, Kyung Tai; Jegal, Hyuk; Kim, Ki Chun; Choo, Ho Sik; Kweon, Heon Ju

    2016-01-01

    Several cases of avulsion fracture of the proximal phalanx of the big toe during the lateral capsular release procedure were observed. However, these fractures have not been reported as a complication of hallux valgus surgery. The purpose of the present study was to report the proximal phalanx base fracture as an unrecognized complication and to evaluate the clinical and radiographic consequences of this complication. We retrospectively reviewed 225 feet that had undergone hallux valgus surgery involving proximal chevron osteotomy and distal soft tissue release from May 2009 to December 2012. Of these 225 feet (198 patients), 12 (5.3%) developed proximal phalanx base fracture postoperatively. These patients were assigned to the fracture group. The remaining patients were assigned to the nonfracture group. Patients were followed to observe whether the fractures united and whether degenerative changes developed at the first metatarsophalangeal joint because of this fracture. The mean follow-up period was 36 (range 12 to 72) months. All the subjects in the fracture and nonfracture groups underwent weightbearing anteroposterior and lateral radiographs of the foot at the initial presentation and final follow-up point. The 2 groups were compared with respect to the hallux valgus angle, intermetatarsal angle, range of motion, American Orthopaedic Foot and Ankle Society score, satisfaction, and degenerative changes. No significant differences were found in age, follow-up period, hallux valgus angle, intermetatarsal angle, range of motion of the first metatarsophalangeal joint, American Orthopaedic Foot and Ankle Society score, satisfaction, and degenerative changes between the 2 groups. Ten (83.3%) of the 12 fractures healed, 2 (16.7% of the fractures, 0.89% of the operated feet) progressed to asymptomatic nonunion, and 3 (1.33%) developed first metatarsophalangeal joint degeneration. Avulsion fracture of the proximal phalanx of the big toe is an uncommon complication of

  15. Proximal tibia stress fracture with Osteoarthritis of knee - Radiological and functional analysis of one stage TKA with long stem.

    Science.gov (United States)

    Soundarrajan, Dhanasekaran; Rajkumar, Natesan; Dhanasekararaja, Palanisamy; Rajasekaran, Shanmuganathan

    2018-01-01

    Proximal tibia stress fractures with knee osteoarthritis pose a challenging situation. We evaluated the radiological and functional outcome of one-stage total knee arthroplasty (TKA) and long stem for patients with varied grades of knee arthritis and proximal tibia stress fractures.  Methods: We analysed 20 patients from April 2012 to March 2017 with proximal tibia stress fractures associated with knee osteoarthritis of varied grades. Out of 20 patients, five were acute fresh fractures. The mean age was 64 years (range, 52-78) which includes three men and 17 women. Previous surgery in the same limb, rheumatoid arthritis, valgus deformity were excluded. All patients were treated with posterior stabilised TKA with long stem, of which, four patients had screw augmentation for medial tibial bone defect and two patients with malunited fracture at stress fracture site required osteotomy, plating and bone grafting. Two patients had two level stress fracture of tibia in the same leg. The mean follow-up period was 28 (range, 6-60) months. The mean tibiofemoral angle improved from 18.27° varus to 1.8° valgus. The mean knee society score improved from 21.9 (range, -10 to 45) to 82.8 (range, 15-99) [p fractures got united at the last follow-up. One patient had infection and wound dehiscence at six months for which debridement done and had poor functional outcome. TKA with long stem gives excellent outcome, irrespective of severity of arthritis associated with stress fracture. By restoring limb alignment and bypassing the fracture site, it facilitates fracture healing. Early detection and prompt intervention is necessary to prevent the progression to recalcitrant non-union or malunion. © The Authors, published by EDP Sciences, 2018.

  16. Proximal tibia stress fracture with Osteoarthritis of knee − Radiological and functional analysis of one stage TKA with long stem

    Science.gov (United States)

    Soundarrajan, Dhanasekaran; Rajkumar, Natesan; Dhanasekararaja, Palanisamy; Rajasekaran, Shanmuganathan

    2018-01-01

    Introduction: Proximal tibia stress fractures with knee osteoarthritis pose a challenging situation. We evaluated the radiological and functional outcome of one-stage total knee arthroplasty (TKA) and long stem for patients with varied grades of knee arthritis and proximal tibia stress fractures.  Methods: We analysed 20 patients from April 2012 to March 2017 with proximal tibia stress fractures associated with knee osteoarthritis of varied grades. Out of 20 patients, five were acute fresh fractures. The mean age was 64 years (range, 52–78) which includes three men and 17 women. Previous surgery in the same limb, rheumatoid arthritis, valgus deformity were excluded. All patients were treated with posterior stabilised TKA with long stem, of which, four patients had screw augmentation for medial tibial bone defect and two patients with malunited fracture at stress fracture site required osteotomy, plating and bone grafting. Two patients had two level stress fracture of tibia in the same leg. Results: The mean follow-up period was 28 (range, 6–60) months. The mean tibiofemoral angle improved from 18.27° varus to 1.8° valgus. The mean knee society score improved from 21.9 (range, −10 to 45) to 82.8 (range, 15–99) [p fractures got united at the last follow-up. One patient had infection and wound dehiscence at six months for which debridement done and had poor functional outcome. Conclusion: TKA with long stem gives excellent outcome, irrespective of severity of arthritis associated with stress fracture. By restoring limb alignment and bypassing the fracture site, it facilitates fracture healing. Early detection and prompt intervention is necessary to prevent the progression to recalcitrant non-union or malunion. PMID:29667926

  17. Personaliotsinguteenust tasub kasutada siis, kui rahaline kokkuhoid pole esmane / Merike Lees

    Index Scriptorium Estoniae

    Lees, Merike, 1976-

    2006-01-01

    Ilmunud ka: Delovõje Vedomosti 1. veebr. lk. 13. Personaliotsinguteenuse kasutamine on õigustatud siis, kui ettevõttes pole personalispetsialisti ning rahaline kokkuhoid pole esmatähtis. Kommenteerivad: Eero Erastus, Madis Sander ja Marti Rehemaa

  18. Proximal Alternating Direction Method with Relaxed Proximal Parameters for the Least Squares Covariance Adjustment Problem

    Directory of Open Access Journals (Sweden)

    Minghua Xu

    2014-01-01

    Full Text Available We consider the problem of seeking a symmetric positive semidefinite matrix in a closed convex set to approximate a given matrix. This problem may arise in several areas of numerical linear algebra or come from finance industry or statistics and thus has many applications. For solving this class of matrix optimization problems, many methods have been proposed in the literature. The proximal alternating direction method is one of those methods which can be easily applied to solve these matrix optimization problems. Generally, the proximal parameters of the proximal alternating direction method are greater than zero. In this paper, we conclude that the restriction on the proximal parameters can be relaxed for solving this kind of matrix optimization problems. Numerical experiments also show that the proximal alternating direction method with the relaxed proximal parameters is convergent and generally has a better performance than the classical proximal alternating direction method.

  19. Percutaneous internal fixation of proximal fifth metatarsal jones fractures (Zones II and III) with Charlotte Carolina screw and bone marrow aspirate concentrate: an outcome study in athletes.

    Science.gov (United States)

    Murawski, Christopher D; Kennedy, John G

    2011-06-01

    Internal fixation is a popular first-line treatment method for proximal fifth metatarsal Jones fractures in athletes; however, nonunions and screw breakage can occur, in part because of nonspecific fixation hardware and poor blood supply. To report the results from 26 patients who underwent percutaneous internal fixation with a specialized screw system of a proximal fifth metatarsal Jones fracture (zones II and III) and bone marrow aspirate concentrate. Case series; Level of evidence, 4. Percutaneous internal fixation for a proximal fifth metatarsal Jones fracture (zones II and III) was performed on 26 athletic patients (mean age, 27.47 years; range, 18-47). All patients were competing at some level of sport and were assessed preoperatively and postoperatively using the Foot and Ankle Outcome Score and SF-12 outcome scores. The mean follow-up time was 20.62 months (range, 12-28). Of the 26 fractures, 17 were traditional zone II Jones fractures, and the remaining 9 were zone III proximal diaphyseal fractures. The mean Foot and Ankle Outcome Score significantly increased, from 51.15 points preoperatively (range, 14-69) to 90.91 at final follow-up (range, 71-100; P fracture healing on standard radiographs was 5 weeks after surgery (range, 4-24). Two patients did not return to their previous levels of sporting activity. One patient experienced a delayed union, and 1 healed but later refractured. Percutaneous internal fixation of proximal fifth metatarsal Jones fractures, with a Charlotte Carolina screw and bone marrow aspirate concentrate, provides more predictable results while permitting athletes a return to sport at their previous levels of competition, with few complications.

  20. Pole Shape Optimization of Permanent Magnet Synchronous Motors Using the Reduced Basis Technique

    Directory of Open Access Journals (Sweden)

    A. Jabbari

    2010-03-01

    Full Text Available In the present work, an integrated method of pole shape design optimization for reduction of torque pulsation components in permanent magnet synchronous motors is developed. A progressive design process is presented to find feasible optimal shapes. This method is applied on the pole shape optimization of two prototype permanent magnet synchronous motors, i.e., 4-poles/6-slots and 4-poles-12slots.

  1. Lunar Meteorites Sayh Al Uhaymir 449 and Dhofar 925, 960, and 961: Windows into South Pole

    Science.gov (United States)

    Ziegler, Ryan A.; Jolliff, B. L.; Korotev, R. L.

    2013-01-01

    In 2003, three lunar meteorites were collected in close proximity to each other in the Dhofar region of Oman: Dhofar 925 (49 g), Dhofar 960 (35 g), and Dhofar 961 (22 g). In 2006, lunar meteorite Sayh al Uhaymir (SaU) 449 (16.5 g) was found about 100 km to the NE. Despite significant differences in the bulk composition of Dhofar 961 relative to Dhofar 925/960 and SaU 449 (which are identical to each other), these four meteorites are postulated to be paired based on their find locations, bulk composition, and detailed petrographic analysis. Hereafter, they will collectively be referred to as the Dhofar 961 clan. Comparison of meteorite and component bulk compositions to Lunar Prospector 5-degree gamma-ray data suggest the most likely provenance of this meteorite group is within the South Pole-Aitken Basin. As the oldest, largest, and deepest recognizable basin on the Moon, the composition of the material within the SPA basin is of particular importance to lunar science. Here we review and expand upon the geochemistry and petrography of the Dhofar 961 clan and assess the likelihood that these meteorites come from within the SPA basin based on their bulk compositions and the compositions and characteristics of the major lithologic components found within the breccia.

  2. Proximal Hamstring Tendinosis and Partial Ruptures.

    Science.gov (United States)

    Startzman, Ashley N; Fowler, Oliver; Carreira, Dominic

    2017-07-01

    Proximal hamstring tendinosis and partial hamstring origin ruptures are painful conditions of the proximal thigh and hip that may occur in the acute, chronic, or acute on chronic setting. Few publications exist related to their diagnosis and management. This systematic review discusses the incidence, treatment, and prognosis of proximal hamstring tendinosis and partial hamstring ruptures. Conservative treatment measures include nonsteroidal anti-inflammatory drugs, physical therapy, rest, and ice. If these measures fail, platelet-rich plasma or shockwave therapy may be considered. When refractory to conservative management, these injuries may be treated with surgical debridement and hamstring reattachment. [Orthopedics. 2017; 40(4):e574-e582.]. Copyright 2017, SLACK Incorporated.

  3. Finite element modeling of small-scale tapered wood-laminated composite poles with biomimicry features

    Science.gov (United States)

    Cheng Piao; Todd F. Shupe; R.C. Tang; Chung Y. Hse

    2008-01-01

    Tapered composite poles with biomimicry features as in bamboo are a new generation of wood laminated composite poles that may some day be considered as an alternative to solid wood poles that are widely used in the transmission and telecommunication fields. Five finite element models were developed with ANSYS to predict and assess the performance of five types of...

  4. Least 1-Norm Pole-Zero Modeling with Sparse Deconvolution for Speech Analysis

    DEFF Research Database (Denmark)

    Shi, Liming; Jensen, Jesper Rindom; Christensen, Mads Græsbøll

    2017-01-01

    In this paper, we present a speech analysis method based on sparse pole-zero modeling of speech. Instead of using the all-pole model to approximate the speech production filter, a pole-zero model is used for the combined effect of the vocal tract; radiation at the lips and the glottal pulse shape...

  5. effect of number of rotor poles on ac losses of permanent magnet

    African Journals Online (AJOL)

    HOD

    A study on permanent magnet (PM) eddy current and core losses of dual-stator PM machines is investigated in this paper. ... material in the retaining sleeves of surface-mounted ... rotor-pole numbers (13-poleand 14-pole in particular) ... Table 2: Optimized Machine Parameters. Number of rotor poles. 4. 5. 7. 8. 10. 11. 13. 14.

  6. The Written-Pole{sup TM} motor: high efficiency - low start current

    Energy Technology Data Exchange (ETDEWEB)

    Beck, B. [C.Eng. Precise Power Corp., Bradenton, FL (United States); Friesen, D. [P.E. Manitoba Hydro, Winnipeg (Canada)

    2000-07-01

    Written-Pole{sup TM} technology is a patented machine technology, which changes the magnetic polarity of the rotor field in a rotating machine, while the machine is operating. The number of poles is thereby changed, resulting in a constant frequency - variable speed machine. When operating as a motor, a Written-Pole machine has inherently low starting current and high operating efficiency. (orig.)

  7. Double Trouble: A Rare Case of Bilateral Upper Pole Ureteropelvic Junction Obstruction

    Directory of Open Access Journals (Sweden)

    Craig A. Peters

    2014-09-01

    Full Text Available A 16-year-old girl presented with bilateral back pain caused by bilateral upper pole ureteropelvic junction obstructions; an extremely rare phenomenon. Bilateral robotically assisted upper pole pyeloplasties were preformed at the same setting with an excellent clinical response. Although rare, upper pole ureteropelvic junction obstruction is a defined entity that urologists should be aware of.

  8. Poles near the thresholds in the coupled ΛN - ΣN system

    International Nuclear Information System (INIS)

    Yamamura, H.; Miyagawa, K.

    1999-01-01

    We find t-matrix poles near the ΣN threshold for the meson theoretical Nijmegen YN interactions including hard-core models. These poles are connected with the strength of the ΛN - ΣN coupling. We also observe antibound-state poles below the ΛN threshold which correlate with scattering lengths. Refs. 4, tabs. 2 (author)

  9. On the ultimate uncertainty of the top quark pole mass

    Energy Technology Data Exchange (ETDEWEB)

    Beneke, M. [Technische Univ. Muenchen, Garching (Germany). Physik-Department; Marquard, P. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Nason, P. [INFN, Sezione di Milano Bicocca (Italy); Steinhauser, M. [Karlsruher Institut fuer Technologie (Germany). Inst. fuer Theoretische Teilchenphysik

    2016-05-15

    We combine the known asymptotic behaviour of the QCD perturbation series expansion, which relates the pole mass of a heavy quark to the MS mass, with the exact series coefficients up to the four-loop order to determine the ultimate uncertainty of the top-quark pole mass due to the renormalon divergence. We perform extensive tests of our procedure by varying the number of colours and flavours, as well as the scale of the strong coupling and the MS mass, and conclude that this uncertainty is around 70 MeV. We further estimate the additional contribution to the mass relation from the five-loop correction and beyond to be 250 MeV.

  10. On the ultimate uncertainty of the top quark pole mass

    International Nuclear Information System (INIS)

    Beneke, M.; Nason, P.; Steinhauser, M.

    2016-05-01

    We combine the known asymptotic behaviour of the QCD perturbation series expansion, which relates the pole mass of a heavy quark to the MS mass, with the exact series coefficients up to the four-loop order to determine the ultimate uncertainty of the top-quark pole mass due to the renormalon divergence. We perform extensive tests of our procedure by varying the number of colours and flavours, as well as the scale of the strong coupling and the MS mass, and conclude that this uncertainty is around 70 MeV. We further estimate the additional contribution to the mass relation from the five-loop correction and beyond to be 250 MeV.

  11. Poles of the Zagreb analysis partial-wave T matrices

    Science.gov (United States)

    Batinić, M.; Ceci, S.; Švarc, A.; Zauner, B.

    2010-09-01

    The Zagreb analysis partial-wave T matrices included in the Review of Particle Physics [by the Particle Data Group (PDG)] contain Breit-Wigner parameters only. As the advantages of pole over Breit-Wigner parameters in quantifying scattering matrix resonant states are becoming indisputable, we supplement the original solution with the pole parameters. Because of an already reported numeric error in the S11 analytic continuation [Batinić , Phys. Rev. CPRVCAN0556-281310.1103/PhysRevC.57.1004 57, 1004(E) (1997); arXiv:nucl-th/9703023], we declare the old BATINIC 95 solution, presently included by the PDG, invalid. Instead, we offer two new solutions: (A) corrected BATINIC 95 and (B) a new solution with an improved S11 πN elastic input. We endorse solution (B).

  12. Study of recursive model for pole-zero cancellation circuit

    International Nuclear Information System (INIS)

    Zhou Jianbin; Zhou Wei; Hong Xu; Hu Yunchuan; Wan Xinfeng; Du Xin; Wang Renbo

    2014-01-01

    The output of charge sensitive amplifier (CSA) is a negative exponential signal with long decay time which will result in undershoot after C-R differentiator. Pole-zero cancellation (PZC) circuit is often applied to eliminate undershoot in many radiation detectors. However, it is difficult to use a zero created by PZC circuit to cancel a pole in CSA output signal accurately because of the influences of electronic components inherent error and environmental factors. A novel recursive model for PZC circuit is presented based on Kirchhoff's Current Law (KCL) in this paper. The model is established by numerical differentiation algorithm between the input and the output signal. Some simulation experiments for a negative exponential signal are carried out using Visual Basic for Application (VBA) program and a real x-ray signal is also tested. Simulated results show that the recursive model can reduce the time constant of input signal and eliminate undershoot. (authors)

  13. Claw-pole Synchronous Generator for Compressed Air Energy Storage

    Directory of Open Access Journals (Sweden)

    PAVEL Valentina

    2013-05-01

    Full Text Available This paper presents a claw-poles generator for compressed air energy storage systems. It is presented the structure of such a system used for compensating of the intermittency of a small wind energy system. For equipping of this system it is chosen the permanent magnet claw pole synchronous generator obtained by using ring NdFeB permanentmagnets instead of excitation coil. In such a way the complexity of the scheme is reduced and the generator become maintenance free. The new magnetic flux density in the air-gap is calculated by magneticreluctance method and by FEM method and the results are compared with measured values in the old and new generator.

  14. On the ultimate uncertainty of the top quark pole mass

    Science.gov (United States)

    Beneke, M.; Marquard, P.; Nason, P.; Steinhauser, M.

    2017-12-01

    We combine the known asymptotic behaviour of the QCD perturbation series expansion, which relates the pole mass of a heavy quark to the MS ‾ mass, with the exact series coefficients up to the four-loop order to determine the ultimate uncertainty of the top-quark pole mass due to the renormalon divergence. We perform extensive tests of our procedure by varying the number of colours and flavours, as well as the scale of the strong coupling and the MS ‾ mass. Including an estimate of the internal bottom and charm quark mass effect, we conclude that this uncertainty is around 110 MeV. We further estimate the additional contribution to the mass relation from the five-loop correction and beyond to be around 300 MeV.

  15. Separate Poles Mode for Large-Capacity HVDC System

    Science.gov (United States)

    Zhu, Lin; Gao, Qin

    2017-05-01

    This paper proposes a novel connection mode, separate poles mode (SPM), for large-capacity HVDC systems. The proposed mode focuses on the core issues of HVDC connection in interconnected power grids and principally aims at increasing effective electric distance between poles, which helps to mitigate the interaction problems between AC system and DC system. Receiving end of bipolar HVDC has been divided into different inverter stations under the mode, and thus significantly alleviates difficulties in power transmission and consumption of receiving-end AC grids. By investigating the changes of multi-feed short-circuit ratio (MISCR), finding that HVDC with SPM shows critical impacts upon itself and other HVDC systems with conventional connection mode, which demonstrates that SPM can make balance between MISCR increase and short-circuit current limit.

  16. Shock wave lithotripsy outcomes for lower pole and non-lower pole stones from a university teaching hospital: Parallel group comparison during the same time period

    Science.gov (United States)

    Geraghty, Robert; Burr, Jacob; Simmonds, Nick; Somani, Bhaskar K.

    2015-01-01

    Introduction: Shock wave lithotripsy (SWL) is a treatment option for all locations of renal and ureteric stones. We compared the results of SWL for lower pole renal stones with all other non-lower pole renal and ureteric stones during the same time period. Material and Methods: All SWL procedures were carried out as day case procedures by a mobile lithotripter from January 2012 to August 2013. The follow-up imaging was a combination of KUB X-ray or USS. Following SWL treatment, the stone free rate (SFR) was defined as ≤3 mm fragments. Results: A total of 148 patients with a mean age of 62 years underwent 201 procedures. Of the 201 procedures, 93 (46%) were for lower pole stones. The non-lower pole stones included upper pole (n = 36), mid pole (n = 40), renal pelvis (n = 10), PUJ (n = 8), mid ureter (n = 3), upper ureter (n = 5) and a combination of upper, middle and/or lower pole (n = 6). The mean stone size for lower pole stones (7.4 mm; range: 4-16 mm) was slightly smaller than non-lower pole stones (8 mm; range: 4-17 mm). The stone fragmentation was successful in 124 (62%) of patients. However, the SFR was statistically significantly better (P = 0.023) for non-lower pole stones 43 (40%) compared to lower pole stones 23 (25%). There were 9 (4%) minor complications and this was not significantly different in the two groups. Conclusions: Although SWL achieves a moderately high stone fragmentation rate with a low complication rate, the SFR is variable depending on the location of stone and the definition of SFR, with lower pole stones fairing significantly worse than stones in all other locations. PMID:25657543

  17. Proton polarimetry using an Enge split-pole spectrograph

    Energy Technology Data Exchange (ETDEWEB)

    Moss, J M; Brown, D R; Cornelius, W D [Texas Agricultural and Mechanical Univ., College Station (USA). Cyclotron Inst.

    1976-05-15

    A high-efficiency (4 x 10/sup -5/ at A=0.4) high resolution (150 keV) polarimeter used in conjunction with an Enge split-pole spectrograph is described. This device permits for the first time polarization transfer studies in elastic scattering. Spectra are shown for /sup 11/B(p(pol),p(pol)')/sup 11/B (2.14 MeV)at Esub(p)=31 MeV.

  18. Prevalent lightning sferics at 600 megahertz near Jupiter's poles

    Science.gov (United States)

    Brown, Shannon; Janssen, Michael; Adumitroaie, Virgil; Atreya, Sushil; Bolton, Scott; Gulkis, Samuel; Ingersoll, Andrew; Levin, Steven; Li, Cheng; Li, Liming; Lunine, Jonathan; Misra, Sidharth; Orton, Glenn; Steffes, Paul; Tabataba-Vakili, Fachreddin; Kolmašová, Ivana; Imai, Masafumi; Santolík, Ondřej; Kurth, William; Hospodarsky, George; Gurnett, Donald; Connerney, John

    2018-06-01

    Lightning has been detected on Jupiter by all visiting spacecraft through night-side optical imaging and whistler (lightning-generated radio waves) signatures1-6. Jovian lightning is thought to be generated in the mixed-phase (liquid-ice) region of convective water clouds through a charge-separation process between condensed liquid water and water-ice particles, similar to that of terrestrial (cloud-to-cloud) lightning7-9. Unlike terrestrial lightning, which emits broadly over the radio spectrum up to gigahertz frequencies10,11, lightning on Jupiter has been detected only at kilohertz frequencies, despite a search for signals in the megahertz range12. Strong ionospheric attenuation or a lightning discharge much slower than that on Earth have been suggested as possible explanations for this discrepancy13,14. Here we report observations of Jovian lightning sferics (broadband electromagnetic impulses) at 600 megahertz from the Microwave Radiometer15 onboard the Juno spacecraft. These detections imply that Jovian lightning discharges are not distinct from terrestrial lightning, as previously thought. In the first eight orbits of Juno, we detected 377 lightning sferics from pole to pole. We found lightning to be prevalent in the polar regions, absent near the equator, and most frequent in the northern hemisphere, at latitudes higher than 40 degrees north. Because the distribution of lightning is a proxy for moist convective activity, which is thought to be an important source of outward energy transport from the interior of the planet16,17, increased convection towards the poles could indicate an outward internal heat flux that is preferentially weighted towards the poles9,16,18. The distribution of moist convection is important for understanding the composition, general circulation and energy transport on Jupiter.

  19. Seasonal Evolution of Titan's Stratosphere Near the Poles

    Science.gov (United States)

    Coustenis, A.; Jennings, D. E.; Achterberg, R. K.; Bampasidis, G.; Nixon, C. A.; Lavvas, P.; Cottini, V.; Flasar, F. M.

    2018-02-01

    In this Letter, we report the monitoring of seasonal evolution near Titan’s poles. We find Titan’s south pole to exhibit since 2010 a strong temperature decrease and a dramatic enhancement of several trace species such as complex hydrocarbons and nitriles (HC3N and C6H6 in particular) previously only observed at high northern latitudes. This results from the seasonal change on Titan going from winter (2002) to summer (2017) in the north and, at the same time, the onset of winter in the south pole. During this transition period atmospheric components with longer chemical lifetimes linger in the north, undergoing slow photochemical destruction, while those with shorter lifetimes decrease and reappear in the south. An opposite effect was expected in the north, but not observed with certainty until now. We present here an analysis of high-resolution nadir spectra acquired by Cassini/Cassini Composite Infrared Spectrometer in the past years and describe the temperature and composition variations near Titan’s poles. From 2013 until 2016, the northern polar region has shown a temperature increase of 10 K, while the south has shown a more significant decrease (up to 25 K) in a similar period of time. While the south polar region has been continuously enhanced since about 2012, the chemical content in the north is finally showing a clear depletion for most molecules only since 2015. This is indicative of a non-symmetrical response to the seasons in Titan’s stratosphere that can set constraints on photochemical and GCM models.

  20. Coherence between geophysical excitations and celestial pole offsets

    Czech Academy of Sciences Publication Activity Database

    Ron, Cyril; Vondrák, Jan

    2011-01-01

    Roč. 8, č. 3 (2011), s. 243-247 ISSN 1214-9705. [Czech-Polish Workshop on Recent Geodynamics of the Sudeten and Adjacent Areas. Třešť, 04.11.2010-06.11. 2010] R&D Projects: GA ČR GA205/08/0908 Institutional research plan: CEZ:AV0Z10030501 Keywords : geophysical excitations * celestial pole offsets * coherence Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 0.530, year: 2011

  1. Pole mass, width, and propagators of unstable fermions

    International Nuclear Information System (INIS)

    Kniehl, B.A.; Sirlin, A.

    2008-01-01

    The concepts of pole mass and width are extended to unstable fermions in the general framework of parity-nonconserving gauge theories, such as the Standard Model. In contrast with the conventional on-shell definitions, these concepts are gauge independent and avoid severe unphysical singularities, properties of great importance since most fundamental fermions in nature are unstable particles. General expressions for the unrenormalized and renormalized dressed propagators of unstable fermions and their field-renormalization constants are presented. (orig.)

  2. Generalised pole-placement control of steam turbine speed

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-del-Busto, R. [ITESM, Cuernavaca (Mexico). Div. de Ingenieria y Ciencias; Munoz, J. [ITESM, Xochimilco (Mexico). Div. de Ingenieria y Ciencias

    1996-12-31

    An application of a pole-placement self-tuning predictive control algorithm is developed to regulate speed of a power plant steam turbine model. Two types of system representation (CARMA and CARIMA) are used to test the control algorithm. Simulation results show that when using a CARMA model better results are produced. Two further comparisons are made when using a PI controller and a generalised predictive controller. (author)

  3. Tööpuudus 29%, palavikku pole / Rachel Donadio

    Index Scriptorium Estoniae

    Donadio, Rachel

    2010-01-01

    Lõuna-Hispaanias asuvas Cádizis on töötus 29%, ometi pole eurotsooni kõrgeim tööpuuduse määr tekitanud linnas sügavat sotsiaalset rahutust ega massilisi proteste, sest üsna kõrge elukvaliteedi tagavad töötutele kompleksne turvavõrk, mis koosneb varimajandusest, perekonna toetusest ja valitsuse toetusest

  4. Dipole Models for UXO Discrimination at Live Sites - Pole Mountain

    Science.gov (United States)

    2012-06-01

    48 ESTCP MR-201159 Pole Mountain Demonstration Report viii April 2012 Acronyms API Application Programming...working on transitioning our inversion algorithms to an API that will be generally accessible. 8 3. PERFORMANCE OBJECTIVES The performance...2098 35 0 0 Frag (light) 6 MD PM-2098 35 0 0 Frag (light) 4 MD PM-2098 35 0 0 Frag (light) 3.5 MD PM-1354 8.5 0 0 Frag (medium) 5 MD PM- 1104 3 15

  5. Clusters of cyclones encircling Jupiter’s poles

    Science.gov (United States)

    Adriani, A.; Mura, A.; Orton, G.; Hansen, C.; Altieri, F.; Moriconi, M. L.; Rogers, J.; Eichstädt, G.; Momary, T.; Ingersoll, A. P.; Filacchione, G.; Sindoni, G.; Tabataba-Vakili, F.; Dinelli, B. M.; Fabiano, F.; Bolton, S. J.; Connerney, J. E. P.; Atreya, S. K.; Lunine, J. I.; Tosi, F.; Migliorini, A.; Grassi, D.; Piccioni, G.; Noschese, R.; Cicchetti, A.; Plainaki, C.; Olivieri, A.; O’Neill, M. E.; Turrini, D.; Stefani, S.; Sordini, R.; Amoroso, M.

    2018-03-01

    The familiar axisymmetric zones and belts that characterize Jupiter’s weather system at lower latitudes give way to pervasive cyclonic activity at higher latitudes. Two-dimensional turbulence in combination with the Coriolis β-effect (that is, the large meridionally varying Coriolis force on the giant planets of the Solar System) produces alternating zonal flows. The zonal flows weaken with rising latitude so that a transition between equatorial jets and polar turbulence on Jupiter can occur. Simulations with shallow-water models of giant planets support this transition by producing both alternating flows near the equator and circumpolar cyclones near the poles. Jovian polar regions are not visible from Earth owing to Jupiter’s low axial tilt, and were poorly characterized by previous missions because the trajectories of these missions did not venture far from Jupiter’s equatorial plane. Here we report that visible and infrared images obtained from above each pole by the Juno spacecraft during its first five orbits reveal persistent polygonal patterns of large cyclones. In the north, eight circumpolar cyclones are observed about a single polar cyclone; in the south, one polar cyclone is encircled by five circumpolar cyclones. Cyclonic circulation is established via time-lapse imagery obtained over intervals ranging from 20 minutes to 4 hours. Although migration of cyclones towards the pole might be expected as a consequence of the Coriolis β-effect, by which cyclonic vortices naturally drift towards the rotational pole, the configuration of the cyclones is without precedent on other planets (including Saturn’s polar hexagonal features). The manner in which the cyclones persist without merging and the process by which they evolve to their current configuration are unknown.

  6. Poled-glass devices: Influence of surfaces and interfaces

    DEFF Research Database (Denmark)

    Fage-Pedersen, Jacob; Jacobsen, Rune Shim; Kristensen, Martin

    2007-01-01

    Devices in periodically poled glass must have a large periodic variation of the built-in field. We show that the periodic variation can be severely degraded by charge dynamics taking place at the external (glass–air) interface or at internal (glass–glass) interfaces if the interfaces have...... the device, one can reveal the existence of imperfect interfaces by use of electric field induced second-harmonic generation....

  7. Development of a superconducting claw-pole motor

    International Nuclear Information System (INIS)

    Watanabe, E.; Kikukawa, K.; Satoh, Y.; Torii, S.

    2008-01-01

    We have developed and produced a superconducting claw-pole motor for a trial purpose as a method to make the best use of the characteristic of superconductivity without collector rings or rotating superconducting coils that need to be cryocooled, and made some examinations. The unique feature in this motor is to have the mechanism that supports the reaction magnetic force generated in the axial direction

  8. Evidence of highly oxidizing environment over the South Pole

    International Nuclear Information System (INIS)

    Davis, D.

    2001-01-01

    Researchers at the Georgia Institute of Technology have discovered high levels of an air purifying chemical or oxidizing agent in the near-surface atmosphere over the South Pole. This research, funded by the National Science Foundation, has implications for interpreting historical global climate records stored in Antarctic ice cores. The hydroxyl (OH) radical is higher at the South Pole than that estimated from OH measurements recorded at the equator. The OH radical is vital to scrubbing pollution and naturally occurring chemicals from the air and prevents a buildup of toxic levels of chemicals. The near surface atmospheric zone is a highly oxidizing environment at the South Pole. There is evidence that oxidizing chemistry continues to occur in the buried snow. This active chemistry could modify chemical species before they are trapped in the ice in their final chemical forms. Therefore, glaciochemists who study climate change based on analysis of trace chemicals trapped in polar ice will have to be more careful in their interpretations of Antarctic ice cores. Any significant increase of nitric oxide levels in any snow-covered area should result in high OH levels. Scientists used the selected-ion chemical ionization mass spectrometer technique to measure OH. To measure nitric oxide (NO), they used chemiluminescence with modifications to improve its sensitivity. Nitric oxide is also a radical and is a by-product of internal combustion engines. At the South Pole, it is formed when ultraviolet radiation interacts with nitrate ions. The source of NO is not clear, but it may originate from stratospheric denitrification and the long-range transport of nitric acid formed at low latitude during electrical storms. Scientists are also working to better understand the oxidation of dimethyl sulfide (DMS) under the cold conditions and high latitudes of Antarctica. This information will help glaciochemists to better interpret sulfate and methane sulfonate concentrations

  9. Stationarity of resonant pole trajectories in complex scaling

    International Nuclear Information System (INIS)

    Canuto, S.; Goscinski, O.

    1978-01-01

    A reciprocity theorem relating the real parameters eta and α that define the complex scaling transformation r → eta r e/sup iα/ in the theory of complex scaling for resonant states is demonstrated. The virial theorem is used in connection with the stationarity of the pole trajectory. The Stark broadening in the hydrogen atom using a basis set generated by Rayleigh--Schroedinger perturbation theory is treated as an example. 18 references

  10. Poling of PVDF matrix composites for integrated structural load sensing

    Science.gov (United States)

    Haghiashtiani, Ghazaleh; Greminger, Michael A.; Zhao, Ping

    2014-03-01

    The purpose of this study is to create and evaluate a smart composite structure that can be used for integrated load sensing and structural health monitoring. In this structure, PVDF films are used as the matrix material instead of epoxy resin or other thermoplastics. The reinforcements are two layers of carbon fiber with one layer of Kevlar separating them. Due to the electrical conductivity properties of carbon fiber and the dielectric effect of Kevlar, the structure acts as a capacitor. Furthermore, the piezoelectric properties of the PVDF matrix can be used to monitor the response of the structure under applied loads. In order to exploit the piezoelectric properties of PVDF, the PVDF material must be polarized to align the dipole moments of its crystalline structure. The optimal condition for poling the structure was found by performing a 23 factorial design of experiment (DoE). The factors that were studied in DoE were temperature, voltage, and duration of poling. Finally, the response of the poled structure was monitored by exposing the samples to an applied load.

  11. Improved technology for spun-cast concrete poles

    Energy Technology Data Exchange (ETDEWEB)

    Dilger, W H; Ghali, A

    1984-07-01

    Different types of concrete were investigated with the goal of developing concrete suitable for the production of spun-cast concrete poles. A total of 65 different concrete mixes were investigated, with the suitability criteria defined as: compactability, no segregation of the mix components during the spinning operation, no shrinkage cracking, high strength, and durability. High strength normal weight concretes and semi-lightweight concretes, both with and without fly ash and/or silica fume and with different types of admixtures were used to produce spun-cast concrete pole segments. Of the 35 lightweight concretes only 3 were considered successful, as in all other specimens the inner layer of coarse aggregate was not well embedded in the mortar, and many mixes could not be compacted properly because they were too stiff, too wet, or started to set before spinning commenced. The three successful specimens contained fly ash and one contained silica fume, and had low water/cement ratios (0.26 to 0.29). Of the 23 normal weight concretes tested, only 5 were considered suitable, and all these had a sand/coarse aggregate ratio of 0.25 or smaller and a cement content between 350 and 400 kg/m{sup 3}. A theoretical study of the stresses in the end zones of pretensioned poles is presented. 10 refs., 53 figs., 14 tabs.

  12. THE SUSTAINABLE DEVELOPMENT OF THE BRASOV GROWTH POLE

    Directory of Open Access Journals (Sweden)

    Aida CATANA

    2016-12-01

    Full Text Available The demographic dynamics analysed in the context of the relationship between economic development and social inclusion presents an image of the sustainable development of a community as well as the manner how the financial resources have been used. With an allocation of 74.3 million euro in the programming period 2007-2013, the Brasov Growth Pole has pursued the contribution to the achievement of sustainable development since 2005 by the participation in the Agenda 21. The implementation of projects with European financing in areas such as transport, social and educational infrastructure or tourism have generated changes/demographic movements, which this paper proposes to present. The evolution of the stable population, its dynamics at the level of each locality that is part of the Brasov growth pole as well as the dynamics of the number of employees or the development of the unemployment rate are presented by the cluster analysis. The effects of the European financing obtained from Regional Operational Programme 2007-2013 are thus reflected in the sustainable development of the Brasov growth pole from the point of view of the dynamics of the population

  13. Lunar South Pole Illumination: Review, Reassessment, and Power System Implications

    Science.gov (United States)

    Fincannon, James

    2007-01-01

    This paper reviews past analyses and research related to lunar south pole illumination and presents results of independent illumination analyses using an analytical tool and a radar digital elevation model. The analysis tool enables assessment at most locations near the lunar poles for any time and any year. Average illumination fraction, energy storage duration, solar/horizon terrain elevation profiles and illumination fraction profiles are presented for various highly illuminated sites which have been identified for manned or unmanned operations. The format of the data can be used by power system designers to develop mass optimized solar and energy storage systems. Data are presented for the worse case lunar day (a critical power planning bottleneck) as well as three lunar days during lunar south pole winter. The main site under consideration by present lunar mission planners (on the Crater Shackleton rim) is shown to have, for the worse case lunar day, a 0.71 average illumination fraction and 73 to 117 hours required for energy storage (depending on power system type). Linking other sites and including towers at either site are shown to not completely eliminate the need for energy storage.

  14. Comparative Investigation on the Performance of Modified System Poles and Traditional System Poles Obtained from PDC Data for Diagnosing the Ageing Condition of Transformer Polymer Insulation Materials

    Directory of Open Access Journals (Sweden)

    Jiefeng Liu

    2018-02-01

    Full Text Available The life expectancy of a transformer is largely depended on the service life of transformer polymer insulation materials. Nowadays, several papers have reported that the traditional system poles obtained from polarization and depolarization current (PDC data can be used to assess the condition of transformer insulation systems. However, the traditional system poles technique only provides limited ageing information for transformer polymer insulation. In this paper, the modified system poles obtained from PDC data are proposed to assess the ageing condition of transformer polymer insulation. The aim of the work is to focus on reporting a comparative investigation on the performance of modified system poles and traditional system poles for assessing the ageing condition of a transformer polymer insulation system. In the present work, a series of experiments have been performed under controlled laboratory conditions. The PDC measurement data, degree of polymerization (DP and moisture content of the oil-immersed polymer pressboard specimens were carefully monitored. It is observed that, compared to the relationships between traditional system poles and DP values, there are better correlations between the modified system poles and DP values, because the modified system poles can obtain much more ageing information on transformer polymer insulation. Therefore, the modified system poles proposed in the paper are more suitable for the diagnosis of the ageing condition of transformer polymer insulation.

  15. Promoting proximal formative assessment with relational discourse

    Science.gov (United States)

    Scherr, Rachel E.; Close, Hunter G.; McKagan, Sarah B.

    2012-02-01

    The practice of proximal formative assessment - the continual, responsive attention to students' developing understanding as it is expressed in real time - depends on students' sharing their ideas with instructors and on teachers' attending to them. Rogerian psychology presents an account of the conditions under which proximal formative assessment may be promoted or inhibited: (1) Normal classroom conditions, characterized by evaluation and attention to learning targets, may present threats to students' sense of their own competence and value, causing them to conceal their ideas and reducing the potential for proximal formative assessment. (2) In contrast, discourse patterns characterized by positive anticipation and attention to learner ideas increase the potential for proximal formative assessment and promote self-directed learning. We present an analysis methodology based on these principles and demonstrate its utility for understanding episodes of university physics instruction.

  16. THE PROXIMATE COMPOSITION OF AFRICAN BUSH MANGO ...

    African Journals Online (AJOL)

    BIG TIMMY

    Information regarding previous studies on these physico-chemical ... This behaviour may be attributed to its high myristic acid ... The authors express deep appreciation to the. Heads of ... of a typical rural processing method on the proximate ...

  17. Proximate composition and nutritional characterization of Chia ...

    African Journals Online (AJOL)

    ... dairy product associated with several beneficial nutritional and health effects. ... The results for amino acids showed that the essential and non-essential amino ... proximate composition and nutritional (amino acids, fatty acids, and minerals ...

  18. Repair and rehabilitation of wood utility poles with fibre-reinforced polymers

    Energy Technology Data Exchange (ETDEWEB)

    Polyzois, D.; Kell, J.A. [Manitoba Univ., Winnipeg, MB (Canada). Dept. of Civil Engineering

    2007-01-15

    In order to ensure safe and reliable service, all wood utility poles need an effective maintenance program. The service life of a wood utility pole depends on several factors, such as decay, mechanical damage, weathering, and changing design requirements. An effective preservative treatment and maintenance program can effectively extend the service life of the wood pole. However, all poles will attain a point when they are no longer suitable for their intended use. New innovative methods are therefore required to restore and maintain the structural integrity of existing wood poles, especially in light of the increasing cost of quality wood for use in poles as well as a result of environmental concerns regarding pole disposal and chemical treatment of existing poles. This article presented results from a research program carried out at the University of Manitoba to develop a repair and rehabilitation technique for wood poles using fibre-reinforced polymers (FRP). It also provided a brief overview of current standards for wood utility poles and reinforcing stubs and discussed the experimental program where long, air-dried jack pine poles were tested in order to evaluate the effectiveness of a proposed rehabilitation system consisting of FRP splines and FRP jackets. The ultimate capacity of the poles was determined using the CSA standard for wood poles. The capacity of the rehabilitated poles was nearly 93 per cent of the average ultimate capacity of the average ultimate capacity of poles tested during the first phase of the study, and 23 per cent higher than the capacity required by CSA standards. 7 refs., 2 figs., 4 tabs.

  19. Proximal focal femoral deficiency: A case report

    Directory of Open Access Journals (Sweden)

    Shashank Sharma

    2015-01-01

    Full Text Available Proximal focal femoral deficiency (PFFD is a rare congenital anomaly resulting in limb shortening and disability in young. The exact cause of the disease is not known and it may present as varying grades of affection involving the proximal femur and the acetabulum. Recognition of this rare abnormality on radiographs can help manage these cases better since early institution of therapy may help in achieving adequate growth of the femur.

  20. Proximity sensor system development. CRADA final report

    International Nuclear Information System (INIS)

    Haley, D.C.; Pigoski, T.M.

    1998-01-01

    Lockheed Martin Energy Research Corporation (LMERC) and Merritt Systems, Inc. (MSI) entered into a Cooperative Research and Development Agreement (CRADA) for the development and demonstration of a compact, modular proximity sensing system suitable for application to a wide class of manipulator systems operated in support of environmental restoration and waste management activities. In teleoperated modes, proximity sensing provides the manipulator operator continuous information regarding the proximity of the manipulator to objects in the workspace. In teleoperated and robotic modes, proximity sensing provides added safety through the implementation of active whole arm collision avoidance capabilities. Oak Ridge National Laboratory (ORNL), managed by LMERC for the United States Department of Energy (DOE), has developed an application specific integrated circuit (ASIC) design for the electronics required to support a modular whole arm proximity sensing system based on the use of capacitive sensors developed at Sandia National Laboratories. The use of ASIC technology greatly reduces the size of the electronics required to support the selected sensor types allowing deployment of many small sensor nodes over a large area of the manipulator surface to provide maximum sensor coverage. The ASIC design also provides a communication interface to support sensor commands from and sensor data transmission to a distributed processing system which allows modular implementation and operation of the sensor system. MSI is a commercial small business specializing in proximity sensing systems based upon infrared and acoustic sensors

  1. Proximity sensor system development. CRADA final report

    Energy Technology Data Exchange (ETDEWEB)

    Haley, D.C. [Oak Ridge National Lab., TN (United States); Pigoski, T.M. [Merrit Systems, Inc. (United States)

    1998-01-01

    Lockheed Martin Energy Research Corporation (LMERC) and Merritt Systems, Inc. (MSI) entered into a Cooperative Research and Development Agreement (CRADA) for the development and demonstration of a compact, modular proximity sensing system suitable for application to a wide class of manipulator systems operated in support of environmental restoration and waste management activities. In teleoperated modes, proximity sensing provides the manipulator operator continuous information regarding the proximity of the manipulator to objects in the workspace. In teleoperated and robotic modes, proximity sensing provides added safety through the implementation of active whole arm collision avoidance capabilities. Oak Ridge National Laboratory (ORNL), managed by LMERC for the United States Department of Energy (DOE), has developed an application specific integrated circuit (ASIC) design for the electronics required to support a modular whole arm proximity sensing system based on the use of capacitive sensors developed at Sandia National Laboratories. The use of ASIC technology greatly reduces the size of the electronics required to support the selected sensor types allowing deployment of many small sensor nodes over a large area of the manipulator surface to provide maximum sensor coverage. The ASIC design also provides a communication interface to support sensor commands from and sensor data transmission to a distributed processing system which allows modular implementation and operation of the sensor system. MSI is a commercial small business specializing in proximity sensing systems based upon infrared and acoustic sensors.

  2. Reconstruction of the Proximal Humerus after Wide Resection of Tumors: Comparison of Three Reconstructive Options

    International Nuclear Information System (INIS)

    EL-SHERBINY, M.

    2008-01-01

    bone flaps were nonunion of one end in 2 cases of PLSCG and one case of FVFG. Limb shortening was seen in 32 cases with PLSCG. Conclusion: Summarizing our experience in this small study, we can state that, limb sparing surgical resection of tumors of the proximal humerus is effective in local tumor control and preserving hand and elbow movements. MSTS functional score of the limb after reconstruction and shoulder fusion with FVFG or PLSCG is nearly the same as mobile shoulder reconstruction with endo prosthesis. Shoulder range of movement was grossly limited with prosthesis replacement while a wider range of movement was obtained with shoulder fusion. Pedicled lateral scapular crest graft is able to bridge defects only up to 12 cm whereas the fibula can replace a longer defect. Selection between those reconstructive options should be individualized and is based on the age, the length of defect, the type of resection, intraarticular or extra articular, preservation of deltoid and axillary nerve, the prognosis of the tumor.

  3. Live imaging of spindle pole disorganization in docetaxel-treated multicolor cells

    International Nuclear Information System (INIS)

    Sakaushi, Shinji; Nishida, Kumi; Minamikawa, Harumi; Fukada, Takashi; Oka, Shigenori; Sugimoto, Kenji

    2007-01-01

    Treatment of cells with docetaxel at low concentrations induces aberrant bipolar spindles of which two centrosomes stay at only one pole, and also induces multipolar spindles. To gain insight into the relations between centrosome impairment and structural defects of the spindle, live-cell imaging was performed on a human MDA Auro/imp/H3 cell line in which centrosomes/mitotic spindles, nuclear membrane and chromatin were simultaneously visualized by fluorescent proteins. In the presence of docetaxel at IC 50 concentration, the centrosomes did not segregate, and multiple aster-like structures ectopically arose around the disappearing nuclear membrane. Those ectopic structures formed an acentrosomal pole opposing to the two-centrosomes-containing pole. In late metaphase, one pole often fragmented into multiple spindle poles, leading multipolar division. These results suggest that spindle pole fragility may be induced by centrosome impairment, and collapse of the pole may contribute to induction of aneuploid daughter cells

  4. Transoral vertebral augmentation with polymethylmethacrylate in the treatment of a patient with a dens fracture nonunion and subarticular vertebral body fracture of C2

    International Nuclear Information System (INIS)

    Beall, Douglas P.; Martin, Hal D.; Stapp, Annette M.; Stanfield, Matthew

    2007-01-01

    The injection of polymethylmethacrylate (PMMA) is a minimally invasive, image-guided procedure used to treat vertebral fractures due to osteoporosis, metastatic lesions, multiple myeloma, and benign but destabilizing bone tumors. The injection of PMMA into the C2 vertebral body using the transoral technique has been reported in three separate patients for treatment of benign tumors (a vertebral hemangioma and an aneurysmal bone cyst) and for multiple myeloma in the third patient. Although the injection of PMMA into the vertebral body is most commonly performed to treat benign vertebral compression fractures, a transoral C2 approach has not been reported in the English literature as a treatment for a benign fracture of C2. We report the treatment of a fracture and nonunion of the base of the dens and a subarticular fracture of the vertebral body of C2 using a bilateral transoral approach. (orig.)

  5. A new internal fixation technique for fractures of the proximal humerus--the Bilboquet device: a report on 26 cases.

    Science.gov (United States)

    Doursounian, L; Grimberg, J; Cazeau, C; Jos, E; Touzard, R C

    2000-01-01

    We describe a novel internal fixation device and report on 26 patients (mean age, 70 years) whose proximal humeral fractures were managed with this technique. The 2-part titanium implant consists of a circular staple impacted into the humeral head cancellous bone and a spigoted diaphyseal stem that inserts into the staple "cup." Of the 26 cases reviewed, 16 had 3-part fractures and 10 had 4-part fractures. Mean follow-up was 25.9 months. In the 16 3-part fractures, the mean active forward elevation was 114 degrees and the results were as follows: excellent, 7; good, 5; fair, 3; poor, 1. In the 10 4-part fracture patients, the mean active forward elevation was 101 degrees and the results were as follows: excellent, 2; good, 4; fair, 3; poor, 1. There were 5 cases of avascular necrosis and 1 case of tuberosity nonunion. Only 2 cases needed conversion to hemiarthroplasty. The new technique should simplify the surgery of these fractures and reduce the need for arthroplasty.

  6. Fibreglass as an alternative to wood poles : Transmission and distribution poles and crossarms : use of fiber reinforced composite materials for overhead electric utility lines

    Energy Technology Data Exchange (ETDEWEB)

    Wiles, J.R. [Shakespeare Composites and Electronics, Newberry, SC (United States)

    2002-07-01

    For over thirty years, Shakespeare Composites and Electronics has manufactured fiberglass composite lighting and utility poles, as well as being the number one maker of composite crossarms. Composite poles have a few advantages, such as being lightweight, they do no rust, are woodpecker and termite resistant, use no harmful chemicals, and have long life. A chart displaying the comparative pole weights is presented. The key design factors of fiberglass composite utility poles are: pole diameter, fiberglass type and wind angle, layers (thickness) of fiberglass, resin type and formulation, resin mix consistency, cure cycle and maximum curing temperature, and others. Two charts were also displayed presenting 40 feet class 4 pole bending strengths and 40 feet class 2 pole bending strengths. The author indicated that composite poles have a better strength consistency than wood, while being as consistent as steel and prestressed concrete. The design is based on an overload factor of safety of 2.5 for numerous installations. Some of the analytical methods used include mechanical testing, finite element modeling, and thermal analysis. The author describes in detail the concerns associated with attachments. Coating consists of a system of ultra violet blockers in the resin followed by an added resin rich polyester veil outer surface. In addition, there is a proprietary coating process with additional ultra violet blockers. Quality control is effected at the plant. The weathering system lasts 80 years. figs.

  7. Interventions for treating proximal humeral fractures in adults.

    Science.gov (United States)

    Handoll, Helen H G; Brorson, Stig

    2015-11-11

    fracture displacement and non-union (2/52 versus 1/54; 2 trials).One quasi-randomised trial (28 participants) found the Gilchrist-type sling was generally more comfortable than the Desault-type sling (body bandage). One trial (48 participants) testing pulsed electromagnetic high-frequency energy provided no evidence. Two trials (62 participants) provided evidence indicating little difference in outcome between instruction for home exercises versus supervised physiotherapy. One trial (48 participants) reported, without presentable data, that home exercise alone gave better early and comparable long-term results than supervised exercise in a swimming pool plus home exercise.Eight trials, involving 567 older participants, evaluated surgical intervention for displaced fractures. There was high quality evidence of no clinically important difference in patient-reported shoulder and upper-limb function at one- or two-year follow-up between surgical (primarily locking plate fixation or hemiarthroplasty) and non-surgical treatment (sling immobilisation) for the majority of displaced proximal humeral fractures; and moderate quality evidence of no clinically important difference between the two groups in quality of life at two years (and at interim follow-ups at six and 12 months). There was moderate quality evidence of little difference between groups in mortality in the surgery group (17/248 versus 12/248; risk ratio (RR) 1.40 favouring non-surgical treatment, 95% confidence interval (CI) 0.69 to 2.83; P = 0.35; 6 trials); only one death was explicitly linked with the treatment. There was moderate quality evidence of a higher risk of additional surgery in the surgery group (34/262 versus 16/261; RR 2.06, 95% CI 1.18 to 3.60; P = 0.01; 7 trials). Although there was moderate evidence of a higher risk of adverse events after surgery, the 95% confidence intervals for adverse events also included the potential for a greater risk of adverse events after non-surgical treatment

  8. Quantum theory of an atom in proximity to a superconductor

    Science.gov (United States)

    Le Dall, Matthias; Diniz, Igor; Dias da Silva, Luis G. G. V.; de Sousa, Rogério

    2018-02-01

    The impact of superconducting correlations on localized electronic states is important for a wide range of experiments in fundamental and applied superconductivity. This includes scanning tunneling microscopy of atomic impurities at the surface of superconductors, as well as superconducting-ion-chip spectroscopy of neutral ions and Rydberg states. Moreover, atomlike centers close to the surface are currently believed to be the main source of noise and decoherence in qubits based on superconducting devices. The proximity effect is known to dress atomic orbitals in Cooper-pair-like states known as Yu-Shiba-Rusinov (YSR) states, but the impact of superconductivity on the measured orbital splittings and optical-noise transitions is not known. Here we study the interplay between orbital degeneracy and particle-number admixture in atomic states, beyond the usual classical spin approximation. We model the atom as a generalized Anderson model interacting with a conventional s -wave superconductor. In the limit of zero on-site Coulomb repulsion (U =0 ), we obtain YSR subgap energy levels that are identical to the ones obtained from the classical spin model. When Δ is large and U >0 , the YSR spectra are no longer quasiparticle-like, and the highly degenerate orbital subspaces are split according to their spin, orbital, and number-parity symmetry. We show that U >0 activates additional poles in the atomic Green's function, suggesting an alternative explanation for the peak splittings recently observed in scanning tunneling microscopy of orbitally-degenerate impurities in superconductors. We describe optical excitation and absorption of photons by YSR states, showing that many additional optical channels open up in comparison to the nonsuperconducting case. Conversely, the additional dissipation channels imply increased electromagnetic noise due to impurities in superconducting devices.

  9. Locking plate fixation for proximal humerus fractures.

    LENUS (Irish Health Repository)

    Burke, Neil G

    2012-02-01

    Locking plates are increasingly used to surgically treat proximal humerus fractures. Knowledge of the bone quality of the proximal humerus is important. Studies have shown the medial and dorsal aspects of the proximal humeral head to have the highest bone strength, and this should be exploited by fixation techniques, particularly in elderly patients with osteoporosis. The goals of surgery for proximal humeral fractures should involve minimal soft tissue dissection and achieve anatomic reduction of the head complex with sufficient stability to allow for early shoulder mobilization. This article reviews various treatment options, in particular locking plate fixation. Locking plate fixation is associated with a high complication rate, such as avascular necrosis (7.9%), screw cutout (11.6%), and revision surgery (13.7%). These complications are frequently due to the varus deformation of the humeral head. Strategic screw placement in the humeral head would minimize the possibility of loss of fracture reduction and potential hardware complications. Locking plate fixation is a good surgical option for the management of proximal humerus fractures. Complications can be avoided by using better bone stock and by careful screw placement in the humeral head.

  10. Giant proximity effect in ferromagnetic bilayers

    Science.gov (United States)

    Ramos, Silvia; Charlton, Tim; Quintanilla, Jorge; Suter, Andreas; Moodera, Jagadeesh; Prokscha, Thomas; Salman, Zaher; Forgan, Ted

    2013-03-01

    The proximity effect is a phenomenon where an ordered state leaks from a material into an adjacent one over some finite distance, ξ. For superconductors, this distance is ~ the coherence length. Nevertheless much longer-range, ``giant'' proximity effects have been observed in cuprate junctions. This surprising effect can be understood as a consequence of critical opalescence. Since this occurs near all second order phase transitions, giant proximity effects should be very general and, in particular, they should be present in magnetic systems. The ferromagnetic proximity effect has the advantage that its order parameter (magnetization) can be observed directly. We investigate the above phenomenon in Co/EuS bilayer films, where both materials undergo ferromagnetic transitions but at rather different temperatures (bulk TC of 1400K for Co and 16.6K for EuS). A dramatic increase in the range of the proximity effect is expected near the TC of EuS. We present the results of our measurements of the magnetization profiles as a function of temperature, carried out using the complementary techniques of low energy muon rotation and polarized neutron reflectivity. Work supported by EPSRC, STFC and ONR grant N00014-09-1-0177 and NSF grant DMR 0504158.

  11. Laparoscopic upper pole heminephroureterectomy in children: Seven-year experience

    Directory of Open Access Journals (Sweden)

    Antonio Marte

    2015-01-01

    Full Text Available Background: Minimally invasive surgery is the current approach to perform heminephroureterectomy (HN in children. This can be obtained through a transperitoneal (TP or a retroperitoneal approach. Here, we report our experience using a TP approach. Materials and Methods: From 2005 to 2014, 22 TP laparoscopic upper poles HN were performed at our institution. There were nine girls and 13 boys aged between 20 months and 6 years (mean age 3.9. Eight patients were diagnosed prenatally, 17 patients presented with urinary tract infection (UTI and three with vomiting and failure to thrive. The indication for HN was reflux nephropathy and UTI in non-functioning upper pole in 19 patients and cystic dysplasia in 1 patient. The surgical technique involved the following steps: Cystoscopic recognition; positioning of 3-4 trocar (right HN; identification of the kidney (detachment of the colon; isolation and low ligation of the dilated ureter; decrossing from renal vessels; section of the parenchyma by LigaSure; haemostasis with clips and LigaSure; drain. Results: The mean operative time was 154 min (range: 81-220 min. All patients were discharged from the 2 nd to 4 th day. Neither major complication nor conversion was recorded. 1 patient presented leakage of urine for 7 days from the drainage which resolved spontaneously. At ultrasound follow-up, 5 patients showed a secondary perirenal cyst, 2-5 cm diameter that resolved spontaneously. Conclusion: The results indicate that laparoscopic upper pole heminephrectomy is the treatment of choice in cases of non-functioning dilated lower segments of duplicated kidneys. The use of laparoscopic approach offers a good working space, a good visual control of the vessels and allows a very low isolation of the ureteral stump which counterbalance the peritoneal violation.

  12. SNAP sky background at the north ecliptic pole

    International Nuclear Information System (INIS)

    Aldering, Greg

    2002-01-01

    I summarize the extant direct and indirect data on the sky background SNAP will see at the North Ecliptic Pole over the wavelength range 0.4 < λ < 1.7 (micro)m. At the spatial resolution of SNAP the sky background due to stars and galaxies is resolved, so the only source considered is zodiacal light. Several models are explored to provide interpolation in wavelength between the broadband data from HST and COBE observations. I believe the input data are now established well enough that the accuracy of the sky background presented here is sufficient for SNAP simulations, and that it will stand up to scrutiny by reviewers

  13. Pole Soccer - Implementering af netværksmodul

    OpenAIRE

    Knudsen, Frank B; Kierkegaard, Jakob R; Hirszhorn, Andreas J

    2005-01-01

    Abstrakt Målet med dette projekt er at designe og implementere et netværksmodul til spillet PoleSoccer, som er et spil udviklet i det foregående semester. Fokus i implementeringen er at opn°a bedst mulig synkronisering klienterne imellem. Programmet er udviklet i programmeringssproget Java. I rapporten diskuteres valg af netværksarkitektur, transportlagsprotokol samt hvilke metoder Java tilbyder til netværkskommunikation, med vægt på Sockets. Ydermere beskrives metoder vi har anvendt til at o...

  14. Superconducting 63-Pole 2 Tesla Wiggler for Canadian Light Source

    International Nuclear Information System (INIS)

    Khruschev, S.V.; Kuper, E.A.; Lev, V.H.; Mezentsev, N.A.; Miginsky, E.G.; Repkov, V.V.; Shkaruba, B.A.; Syrovatin, V.M.; Tsukanov, V.M.

    2006-01-01

    A superconducting 63-pole wiggler with the average period 34 mm designed and fabricated at the Institute of Nuclear Physics in Novosibirsk for Synchrotron Radiation Center (CLS) in Canada is described. The maximum field 2.2 Tesla in the median plane has been achieved. The liquid helium consumption less than 0.03 liters per hour in operating mode has been reached. In January 2005, the wiggler was installed in the storage ring in CLS and now experiments are already underway. The main parameters of the magnet and the cryogenic systems as well as test results are presented

  15. Superconducting 63-pole 2 T wiggler for Canadian Light Source

    International Nuclear Information System (INIS)

    Khruschev, S.V.; Kuper, E.A.; Lev, V.H.; Mezentsev, N.A.; Miginsky, E.G.; Repkov, V.V.; Shkaruba, V.A.; Syrovatin, V.M.; Tsukanov, V.M.

    2007-01-01

    A superconducting 63-pole wiggler with the average period 34 mm designed and fabricated in the Institute of Nuclear Physics in Novosibirsk for Synchrotron Radiation Center Canadian Light Source (CLS) in Canada is described. The maximum field 2.2 T in the median plane has been achieved. The liquid helium consumption less than 0.03 L h in operating mode has been reached. It allows refilling liquid helium once a year. In January 2005, the wiggler was installed in the storage ring in CLS and now experiments are carried out. The main parameters of the magnet and the cryogenic systems as well as test results are presented

  16. IMF sector behavior estimated from geomagnetic data at South Pole

    International Nuclear Information System (INIS)

    Matsushita, S.; Xu, W.h.

    1981-01-01

    IMF sector behavior which has previously been estimated from the geomagnetic data at Godhavn is confirmed by study of the data at South Pole for 1959--1970 with the same estimation technique, taking the difference between northern and southern hemispheres into consideration. A method to improve (about 18%) the agreement between assigned and actual sector structures by study of the data at the two stations is suggested. Geomagnetic disturbance effects on sector estimation are discussed, and reversed sector effects in winter are given special emphasis

  17. Are Narrow Line Seyfert 1 Galaxies Viewed Pole-on?

    Science.gov (United States)

    2011-04-01

    0.2’’ respectively. Figure 1 displays the position of each slit over a Barbosa et al. (2009) GMOS IFU image of the [S III] flux (which originates...C. Winge, H. Schmitt: Gemini/ GMOS IFU gas velocity ’tomography’ of the narrow line region of nearby active galaxies, MNRAS, 396 (2009) 2. [2] D...1995) 81. 4 P o S ( N L S 1 ) 0 5 0 Are NLS1s Pole-on? Travis C. Fischer 5 Figure 1: NGC 4051 GMOS IFU image showing integrated [SIII] flux

  18. Ülikoolid pole mängukannid / Sirje Tohver

    Index Scriptorium Estoniae

    Tohver, Sirje

    2001-01-01

    TPÜ korraldas 16. märtsil̀ 2001 ümarlaua "Ülikoolid pole mängukannid", kus oli arutusel riikliku koolitustellimuse vähenemine avalik-õiguslikele ülikoolidele. Osalesid TPÜ filoloogiateaduskonna dekaan dots. H. Mattisen, kultuuriteaduskonna dekaan prof. A. Avarand, akadeemiline prorektor dots. L. Jõgi, teadus- ja arendusprorektor prof. P. Normak, haridusminister T. Lukas, TPÜ rektor prof. M. Arvisto ja EKA rektor prof. A. Keskküla, TTÜ rektor prof. A. Keevallik, EMA õppeprorektor A. Pung

  19. DETECTION AND CLASSIFICATION OF POLE-LIKE OBJECTS FROM MOBILE MAPPING DATA

    Directory of Open Access Journals (Sweden)

    K. Fukano

    2015-08-01

    Full Text Available Laser scanners on a vehicle-based mobile mapping system can capture 3D point-clouds of roads and roadside objects. Since roadside objects have to be maintained periodically, their 3D models are useful for planning maintenance tasks. In our previous work, we proposed a method for detecting cylindrical poles and planar plates in a point-cloud. However, it is often required to further classify pole-like objects into utility poles, streetlights, traffic signals and signs, which are managed by different organizations. In addition, our previous method may fail to extract low pole-like objects, which are often observed in urban residential areas. In this paper, we propose new methods for extracting and classifying pole-like objects. In our method, we robustly extract a wide variety of poles by converting point-clouds into wireframe models and calculating cross-sections between wireframe models and horizontal cutting planes. For classifying pole-like objects, we subdivide a pole-like object into five subsets by extracting poles and planes, and calculate feature values of each subset. Then we apply a supervised machine learning method using feature variables of subsets. In our experiments, our method could achieve excellent results for detection and classification of pole-like objects.

  20. Investigation Effects of Narrowing Rotor Pole Embrace to Efficiency and Cogging Torque at PM BLDC Motor

    Directory of Open Access Journals (Sweden)

    Cemil Ocak

    2016-02-01

    Full Text Available Engineers think that pole embrace size of a PM BLDC motor affects directly the efficiency and the torque. Dealing with theexperimental research, in the studywe have investigated the effects of narrowing rotor pole embrace step by step by changing sizes parametrically. By doing so, high efficiency and low cogging torque would have been obtained for a 20 W PM BLDC motor. In order to do this,pole arc to pole pitch ratio of magnets at the rotor poles has been changed parametrically (0.5 to 1 by genetic algorithm methodfirst. Then the electromagnetic field dispersions, output parameters of the motor, new rotor constructions have been obtained; and new pole embrace has been derived from the variation of pole arc to pole pitch ratio. We have also calculatedthe magnetic flux distribution, output power, torque, cogging torque and efficiency values analytically and the effects of new pole embrace to motor efficiency and torque have been simulated. The developed 18 slots, 6 poles, surface mounted inner runner configuration rotor machine is proposed as to be used insmall dentistry apparatus.

  1. Proximity operations concept design study, task 6

    Science.gov (United States)

    Williams, A. N.

    1990-01-01

    The feasibility of using optical technology to perform the mission of the proximity operations communications subsystem on Space Station Freedom was determined. Proximity operations mission requirements are determined and the relationship to the overall operational environment of the space station is defined. From this information, the design requirements of the communication subsystem are derived. Based on these requirements, a preliminary design is developed and the feasibility of implementation determined. To support the Orbital Maneuvering Vehicle and National Space Transportation System, the optical system development is straightforward. The requirements on extra-vehicular activity are such as to allow large fields of uncertainty, thus exacerbating the acquisition problem; however, an approach is given that could mitigate this problem. In general, it is found that such a system could indeed perform the proximity operations mission requirement, with some development required to support extra-vehicular activity.

  2. Endomedullar nail of metacarpal and proximal phalanges

    International Nuclear Information System (INIS)

    Mendez Olaya, Francisco Javier; Sanchez Mesa, Pedro Antonio

    2002-01-01

    Prospective study, series of cases; it included patients with diaphysis fractures and union diaphysis-neck or union diaphysis-base of metacarpal and proximal phalanges, in whom was practiced anterograde intramedullary nailing previous closed reduction of the fracture, using prevent intramedullary nail of 1.6 mm. (cem 16) for the metacarpal fractures, and two nail prevent of 1.0 mm. (cem 10) for the proximal phalangeal fractures. Indications: transverse and oblique short fractures, spiral and with comminuting bicortical. Pursuit average is 5.7 months. Frequency surgical intervened patient: 2.2 each month, using this surgical technique a total of 20 (twenty) patients have been operated, 21 (twenty one) fractures; 16 (sixteen) metacarcal fractures and 5 (five) proximal phalangeal fractures, all of them tested using clinical and radiological parameters. Results: good 82%, regular 18%, and bad 0% obtaining bony consolidation and early rehabilitation with incorporation to their habitual works

  3. Correlation between social proximity and mobility similarity.

    Science.gov (United States)

    Fan, Chao; Liu, Yiding; Huang, Junming; Rong, Zhihai; Zhou, Tao

    2017-09-20

    Human behaviors exhibit ubiquitous correlations in many aspects, such as individual and collective levels, temporal and spatial dimensions, content, social and geographical layers. With rich Internet data of online behaviors becoming available, it attracts academic interests to explore human mobility similarity from the perspective of social network proximity. Existent analysis shows a strong correlation between online social proximity and offline mobility similarity, namely, mobile records between friends are significantly more similar than between strangers, and those between friends with common neighbors are even more similar. We argue the importance of the number and diversity of common friends, with a counter intuitive finding that the number of common friends has no positive impact on mobility similarity while the diversity plays a key role, disagreeing with previous studies. Our analysis provides a novel view for better understanding the coupling between human online and offline behaviors, and will help model and predict human behaviors based on social proximity.

  4. Evaluation and Management of Proximal Humerus Fractures

    Directory of Open Access Journals (Sweden)

    Ekaterina Khmelnitskaya

    2012-01-01

    Full Text Available Proximal humerus fractures are common injuries, especially among older osteoporotic women. Restoration of function requires a thorough understanding of the neurovascular, musculotendinous, and bony anatomy. This paper addresses the relevant anatomy and highlights various management options, including indication for arthroplasty. In the vast majority of cases, proximal humerus fractures may be treated nonoperatively. In the case of displaced fractures, when surgical intervention may be pursued, numerous constructs have been investigated. Of these, the proximal humerus locking plate is the most widely used. Arthroplasty is generally reserved for comminuted 4-part fractures, head-split fractures, or fractures with significant underlying arthritic changes. Reverse total shoulder arthroplasty is reserved for patients with a deficient rotator cuff, or highly comminuted tuberosities.

  5. The Life Saving Effects of Hospital Proximity

    DEFF Research Database (Denmark)

    Bertoli, Paola; Grembi, Veronica

    We assess the lifesaving effect of hospital proximity using data on fatality rates of road-traffic accidents. While most of the literature on this topic is based on changes in distance to the nearest hospital triggered by hospital closures and use OLS estimates, our identification comes from......) increases the fatality rate by 13.84% on the sample average. This is equal to a 0.92 additional death per every 100 accidents. We show that OLS estimates provide a downward biased measure of the real effect of hospital proximity because they do not fully solve spatial sorting problems. Proximity matters...... more when the road safety is low; the emergency service is not properly organized, and the nearest hospital has lower quality standards....

  6. Proximity functions for general right cylinders

    International Nuclear Information System (INIS)

    Kellerer, A.M.

    1981-01-01

    Distributions of distances between pairs of points within geometrical objects, or the closely related proximity functions and geometric reduction factors, have applications to dosimetric and microdosimetric calculations. For convex bodies these functions are linked to the chord-length distributions that result from random intersections by straight lines. A synopsis of the most important relations is given. The proximity functions and related functions are derived for right cylinders with arbitrary cross sections. The solution utilizes the fact that the squares of the distances between two random points are sums of independently distributed squares of distances parallel and perpendicular to the axis of the cylinder. Analogous formulas are derived for the proximity functions or geometric reduction factors for a cylinder relative to a point. This requires only a minor modification of the solution

  7. Industrial Computed Tomography using Proximal Algorithm

    KAUST Repository

    Zang, Guangming

    2016-04-14

    In this thesis, we present ProxiSART, a flexible proximal framework for robust 3D cone beam tomographic reconstruction based on the Simultaneous Algebraic Reconstruction Technique (SART). We derive the proximal operator for the SART algorithm and use it for minimizing the data term in a proximal algorithm. We show the flexibility of the framework by plugging in different powerful regularizers, and show its robustness in achieving better reconstruction results in the presence of noise and using fewer projections. We compare our framework to state-of-the-art methods and existing popular software tomography reconstruction packages, on both synthetic and real datasets, and show superior reconstruction quality, especially from noisy data and a small number of projections.

  8. [Partial replantation following proximal limb injury].

    Science.gov (United States)

    Dubert, T; Malikov, S A; Dinh, A; Kupatadze, D D; Oberlin, C; Alnot, J Y; Nabokov, B B

    2000-11-01

    Proximal replantation is a technically feasible but life-threatening procedure. Indications must be restricted to patients in good condition with a good functional prognosis. The goal of replantation must be focused not only on reimplanting the amputated limb but also on achieving a good functional outcome. For the lower limb, simple terminalization remains the best choice in many cases. When a proximal amputation is not suitable for replantation, the main aim of the surgical procedure must be to reconstruct a stump long enough to permit fitting a prosthesis preserving the function of the adjacent joint. If the proximal stump beyond the last joint is very short, it may be possible to restore some length by partial replantation of spared tissues from the amputated part. We present here the results we obtained following this policy. This series included 16 cases of partial replantations, 14 involving the lower limb and 2 the upper limb. All were osteocutaneous microsurgical transfers. For the lower limb, all transfers recovered protective sensitivity following tibial nerve repair. The functional calcaeoplantar unit was used in 13 cases. The transfer of this specialized weight bearing tissue provided a stable distal surface making higher support unnecessary. In one case, we raised a 13-cm vascularized tibial segment covered with foot skin for additional length. For the upper limb, the osteocutaneous transfer, based on the radial artery, was not reinnervated, but this lack of sensitivity did not impair prosthesis fitting. One vascular failure was finally amputated. This was the only unsuccessful result. For all other patients, the surgical procedure facilitated prosthesis fitting and preserved the proximal joint function despite an initially very proximal amputation. The advantages of partial replantation are obvious compared with simple terminalization or secondary reconstruction. There is no secondary donor site and, because there is no major muscle mass in the

  9. The developmental spectrum of proximal radioulnar synostosis

    Energy Technology Data Exchange (ETDEWEB)

    Elliott, Alison M. [University of Manitoba, Winnipeg Regional Health Association Program of Genetics and Metabolism, Winnipeg, MB (Canada); University of Manitoba, Department of Paediatrics and Child Health, Winnipeg, MB (Canada); University of Manitoba, Department of Biochemistry and Medical Genetics, Winnipeg, MB (Canada); University of Manitoba, WRHA Program of Genetics and Metabolism, Departments of Paediatrics and Child Health, Biochemistry and Medical Genetics, Winnipeg, MB (Canada); Kibria, Lisa [University of Manitoba, Department of School of Medical Rehabilitation, Winnipeg, MB (Canada); Reed, Martin H. [University of Manitoba, Department of Paediatrics and Child Health, Winnipeg, MB (Canada); University of Manitoba, Department of Biochemistry and Medical Genetics, Winnipeg, MB (Canada); University of Manitoba, Department of Diagnostic Imaging, Winnipeg, MB (Canada)

    2010-01-15

    Proximal radioulnar synostosis is a rare upper limb malformation. The elbow is first identifiable at 35 days (after conception), at which stage the cartilaginous anlagen of the humerus, radius and ulna are continuous. Subsequently, longitudinal segmentation produces separation of the distal radius and ulna. However, temporarily, the proximal ends are united and continue to share a common perichondrium. We investigated the hypothesis that posterior congenital dislocation of the radial head and proximal radioulnar fusion are different clinical manifestations of the same primary developmental abnormality. Records were searched for ''proximal radioulnar fusion/posterior radial head dislocation'' in patients followed at the local Children's Hospital and Rehabilitation Centre for Children. Relevant radiographic, demographic and clinical data were recorded. Ethics approval was obtained through the University Research Ethics Board. In total, 28 patients met the inclusion criteria. The majority of patients (16) had bilateral involvement; eight with posterior dislocation of the radial head only; five had posterior radial head dislocation with radioulnar fusion and two had radioulnar fusion without dislocation. One patient had bilateral proximal radioulnar fusion and posterior dislocation of the left radial head. Nine patients had only left-sided involvement, and three had only right-sided involvement.The degree of proximal fusion varied, with some patients showing 'complete' proximal fusion and others showing fusion that occurred slightly distal to the radial head: 'partially separated.' Associated disorders in our cohort included Poland syndrome (two patients), Cornelia de Lange syndrome, chromosome anomalies (including tetrasomy X) and Cenani Lenz syndactyly. The suggestion of a developmental relationship between posterior dislocation of the radial head and proximal radioulnar fusion is supported by the fact that both anomalies

  10. Proximity effects in ferromagnet/superconductor structures

    International Nuclear Information System (INIS)

    Yu, H.L.; Sun, G.Y.; Yang, L.Y.; Xing, D.Y.

    2004-01-01

    The Nambu spinor Green's function approach is applied to study proximity effects in ferromagnet/superconductor (FM/SC) structures. They include the induced superconducting order parameter and density of states (DOS) with superconducting feature on the FM side, and spin-dependent DOS within the energy gap on the SC side. The latter indicates an appearance of gapless superconductivity and a coexistence of ferromagnetism and superconductivity in a small regime near the interface. The influence of exchange energy in FM and barrier strength at interface on the proximity effects is discussed

  11. Ultimate and proximate explanations of strong reciprocity.

    Science.gov (United States)

    Vromen, Jack

    2017-08-23

    Strong reciprocity (SR) has recently been subject to heated debate. In this debate, the "West camp" (West et al. in Evol Hum Behav 32(4):231-262, 2011), which is critical of the case for SR, and the "Laland camp" (Laland et al. in Science, 334(6062):1512-1516, 2011, Biol Philos 28(5):719-745, 2013), which is sympathetic to the case of SR, seem to take diametrically opposed positions. The West camp criticizes advocates of SR for conflating proximate and ultimate causation. SR is said to be a proximate mechanism that is put forward by its advocates as an ultimate explanation of human cooperation. The West camp thus accuses advocates of SR for not heeding Mayr's original distinction between ultimate and proximate causation. The Laland camp praises advocates of SR for revising Mayr's distinction. Advocates of SR are said to replace Mayr's uni-directional view on the relation between ultimate and proximate causes by the bi-directional one of reciprocal causation. The paper argues that both the West camp and the Laland camp misrepresent what advocates of SR are up to. The West camp is right that SR is a proximate cause of human cooperation. But rather than putting forward SR as an ultimate explanation, as the West camp argues, advocates of SR believe that SR itself is in need of ultimate explanation. Advocates of SR tend to take gene-culture co-evolutionary theory as the correct meta-theoretical framework for advancing ultimate explanations of SR. Appearances notwithstanding, gene-culture coevolutionary theory does not imply Laland et al.'s notion of reciprocal causation. "Reciprocal causation" suggests that proximate and ultimate causes interact simultaneously, while advocates of SR assume that they interact sequentially. I end by arguing that the best way to understand the debate is by disambiguating Mayr's ultimate-proximate distinction. I propose to reserve "ultimate" and "proximate" for different sorts of explanations, and to use other terms for distinguishing

  12. Infiltrating/sealing proximal caries lesions

    DEFF Research Database (Denmark)

    Martignon, S; Ekstrand, K R; Gomez, J

    2012-01-01

    This randomized split-mouth controlled clinical trial aimed at assessing the therapeutic effects of infiltration vs. sealing for controlling caries progression on proximal surfaces. Out of 90 adult students/patients assessed at university clinics and agreeing to participate, 39, each with 3...... differences in lesion progression between infiltration and placebo (P = 0.0012) and between sealing and placebo (P = 0.0269). The study showed that infiltration and sealing are significantly better than placebo treatment for controlling caries progression on proximal lesions. No significant difference...

  13. Effects of slotting and unipolar flux on magnetic pull in a two-pole induction motor with an extra four-pole stator winding

    Energy Technology Data Exchange (ETDEWEB)

    Sinervo, A.

    2013-06-01

    This thesis is about the radial magnetic forces between the rotor and stator in twopole induction machines. The magnetic forces arise from rotor eccentricity. The asymmetric air-gap makes the flux density on one side of the rotor stronger than on the opposite side. This produces magnetic pull. The magnetic flux density distribution in the air-gap can be expressed with spatial harmonics, i.e. flux densities with different pole-pair numbers. In two-pole machines, the main part of the magnetic force is produced by the interaction of two- and fourpole flux unless the four-pole flux is damped by parallel paths in the stator winding or an extra four-pole stator winding. The rest of the force comes from the interaction of two-pole and unipolar flux and from the higher harmonics of the air-gap flux of which the slot harmonics are a major part. The force caused by the higher harmonics and the unipolar flux is studied in the case where a four-pole stator winding is used to reduce the four-pole flux. The higher harmonics are found to produce, in addition to the traditional unbalanced magnetic pull, a force similar to the effect of the unipolar flux and the two can be distinguished only by measuring the unipolar flux. In measurements at various operation points, the higher harmonics are found to produce much more force than the unipolar flux and two-pole flux but the unipolar flux is still significant. The four-pole winding also is used to actively control the four-pole flux and the magnetic forces. Designing the controller requires a low order model of the system. Such a model is derived and the effect of the slot harmonics and the unipolar flux are included in the model. Different measurements techniques and methods are presented to identify and validate the control model. The operation point dependence of the system dynamics is studied via measurements. All results are obtained from a 30 kW test motor. The rotor of the test machine has a long flexible shaft on external

  14. Semantic representations in the temporal pole predict false memories

    Science.gov (United States)

    Chadwick, Martin J.; Anjum, Raeesa S.; Kumaran, Dharshan; Schacter, Daniel L.; Spiers, Hugo J.; Hassabis, Demis

    2016-01-01

    Recent advances in neuroscience have given us unprecedented insight into the neural mechanisms of false memory, showing that artificial memories can be inserted into the memory cells of the hippocampus in a way that is indistinguishable from true memories. However, this alone is not enough to explain how false memories can arise naturally in the course of our daily lives. Cognitive psychology has demonstrated that many instances of false memory, both in the laboratory and the real world, can be attributed to semantic interference. Whereas previous studies have found that a diverse set of regions show some involvement in semantic false memory, none have revealed the nature of the semantic representations underpinning the phenomenon. Here we use fMRI with representational similarity analysis to search for a neural code consistent with semantic false memory. We find clear evidence that false memories emerge from a similarity-based neural code in the temporal pole, a region that has been called the “semantic hub” of the brain. We further show that each individual has a partially unique semantic code within the temporal pole, and this unique code can predict idiosyncratic patterns of memory errors. Finally, we show that the same neural code can also predict variation in true-memory performance, consistent with an adaptive perspective on false memory. Taken together, our findings reveal the underlying structure of neural representations of semantic knowledge, and how this semantic structure can both enhance and distort our memories. PMID:27551087

  15. Semantic representations in the temporal pole predict false memories.

    Science.gov (United States)

    Chadwick, Martin J; Anjum, Raeesa S; Kumaran, Dharshan; Schacter, Daniel L; Spiers, Hugo J; Hassabis, Demis

    2016-09-06

    Recent advances in neuroscience have given us unprecedented insight into the neural mechanisms of false memory, showing that artificial memories can be inserted into the memory cells of the hippocampus in a way that is indistinguishable from true memories. However, this alone is not enough to explain how false memories can arise naturally in the course of our daily lives. Cognitive psychology has demonstrated that many instances of false memory, both in the laboratory and the real world, can be attributed to semantic interference. Whereas previous studies have found that a diverse set of regions show some involvement in semantic false memory, none have revealed the nature of the semantic representations underpinning the phenomenon. Here we use fMRI with representational similarity analysis to search for a neural code consistent with semantic false memory. We find clear evidence that false memories emerge from a similarity-based neural code in the temporal pole, a region that has been called the "semantic hub" of the brain. We further show that each individual has a partially unique semantic code within the temporal pole, and this unique code can predict idiosyncratic patterns of memory errors. Finally, we show that the same neural code can also predict variation in true-memory performance, consistent with an adaptive perspective on false memory. Taken together, our findings reveal the underlying structure of neural representations of semantic knowledge, and how this semantic structure can both enhance and distort our memories.

  16. Towards a research pole in photonics in Western Romania

    Science.gov (United States)

    Duma, Virgil-Florin; Negrutiu, Meda L.; Sinescu, Cosmin; Rominu, Mihai; Miutescu, Eftimie; Burlea, Amelia; Vlascici, Miomir; Gheorghiu, Nicolae; Cira, Octavian; Hutiu, Gheorghe; Mnerie, Corina; Demian, Dorin; Marcauteanu, Corina; Topala, Florin; Rolland, Jannick P.; Voiculescu, Ioana; Podoleanu, Adrian G.

    2014-07-01

    We present our efforts in establishing a Research Pole in Photonics in the future Arad-Timisoara metropolitan area projected to unite two major cities of Western Romania. Research objectives and related training activities of various institutions and groups that are involved are presented in their evolution during the last decade. The multi-disciplinary consortium consists principally of two universities, UAVA (Aurel Vlaicu University of Arad) and UMF (Victor Babes Medicine and Pharmacy University of Timisoara), but also of the Arad County Emergency University Hospital and several innovative SMEs, such as Bioclinica S.A. (the largest array of medical analysis labs in the region) and Inteliform S.R.L. (a competitive SME focused on mechatronics and mechanical engineering). A brief survey of the individual and joint projects of these institutions is presented, together with their teaching activities at graduate and undergraduate level. The research Pole collaborates in R&D, training and education in biomedical imaging with universities in USA and Europe. Collaborative activities, mainly on Optical Coherence Tomography (OCT) projects are presented in a multidisciplinary approach that includes optomechatronics, precision mechanics and optics, dentistry, medicine, and biology.

  17. Acoustic wave filter based on periodically poled lithium niobate.

    Science.gov (United States)

    Courjon, Emilie; Bassignot, Florent; Ulliac, Gwenn; Benchabane, Sarah; Ballandras, Sylvain

    2012-09-01

    Solutions for the development of compact RF passive transducers as an alternative to standard surface or bulk acoustic wave devices are receiving increasing interest. This article presents results on the development of an acoustic band-pass filter based on periodically poled ferroelectric domains in lithium niobate. The fabrication of periodically poled transducers (PPTs) operating in the range of 20 to 650 MHz has been achieved on 3-in (76.2-mm) 500-μm-thick wafers. This kind of transducer is able to excite elliptical as well as longitudinal modes, yielding phase velocities of about 3800 and 6500 ms(-1), respectively. A new type of acoustic band-pass filter is proposed, based on the use of PPTs instead of the SAWs excited by classical interdigital transducers. The design and the fabrication of such a filter are presented, as well as experimental measurements of its electrical response and transfer function. The feasibility of such a PPT-based filter is thereby demonstrated and the limitations of this method are discussed.

  18. A precise determination of the top-quark pole mass

    International Nuclear Information System (INIS)

    Wang, Sheng-Quan; Wu, Xing-Gang; Si, Zong-Guo; Brodsky, Stanley J.

    2018-01-01

    The Principle of Maximum Conformality (PMC) provides a systematic way to eliminate the renormalization scheme and renormalization scale uncertainties for high-energy processes. We have observed that by applying PMC scale setting, one obtains comprehensive and self-consistent pQCD predictions for the top-quark pair total cross section and the top-quark pair forward-backward asymmetry in agreement with the measurements at the Tevatron and LHC. As a step forward, in the present paper, we determine the top-quark pole mass via a detailed comparison of the top-quark pair cross section with the measurements at the Tevatron and LHC. The results for the top-quark pole mass are m t = 174.6 +3.1 -3.2 GeV for the Tevatron with √(S) = 1.96 TeV, m t = 173.7 ± 1.5 and 174.2 ± 1.7 GeV for the LHC with √(S) = 7 and 8 TeV, respectively. Those predictions agree with the average, 173.34 ± 0.76 GeV, obtained from various collaborations via direct measurements. The consistency of the pQCD predictions using the PMC with all of the collider measurements at different energies provides an important verification of QCD. (orig.)

  19. A precise determination of the top-quark pole mass

    Science.gov (United States)

    Wang, Sheng-Quan; Wu, Xing-Gang; Si, Zong-Guo; Brodsky, Stanley J.

    2018-03-01

    The Principle of Maximum Conformality (PMC) provides a systematic way to eliminate the renormalization scheme and renormalization scale uncertainties for high-energy processes. We have observed that by applying PMC scale setting, one obtains comprehensive and self-consistent pQCD predictions for the top-quark pair total cross section and the top-quark pair forward-backward asymmetry in agreement with the measurements at the Tevatron and LHC. As a step forward, in the present paper, we determine the top-quark pole mass via a detailed comparison of the top-quark pair cross section with the measurements at the Tevatron and LHC. The results for the top-quark pole mass are m_t=174.6^{+3.1}_{-3.2} GeV for the Tevatron with √{S}=1.96 TeV, m_t=173.7± 1.5 and 174.2± 1.7 GeV for the LHC with √{S} = 7 and 8 TeV, respectively. Those predictions agree with the average, 173.34± 0.76 GeV, obtained from various collaborations via direct measurements. The consistency of the pQCD predictions using the PMC with all of the collider measurements at different energies provides an important verification of QCD.

  20. Elemental Mercury Diffusion Processes and Concentration at the Lunar Poles

    Science.gov (United States)

    Moxley, Frederick; Killen, Rosemary M.; Hurley, Dana M.

    2011-01-01

    In 2009, the Lyman Alpha Mapping Project (LAMP) spectrograph onboard the Lunar Reconnaissance Orbiter (LRO) spacecraft made the first detection of element mercury (Hg) vapor in the lunar exosphere after the Lunar Crater Observing and Sensing Satellite (LCROSS) Centaur rocket impacted into the Cabeus crater in the southern polar region of the Moon. The lunar regolith core samples from the Apollo missions determined that Hg had a devolatilized pattern with a concentration gradient increasing with depth, in addition to a layered pattern suggesting multiple episodes of burial and volatile loss. Hg migration on the lunar surface resulted in cold trapping at the poles. We have modeled the rate at which indigenous Hg is lost from the regolith through diffusion out of lunar grains. We secondly modeled the migration of Hg vapor in the exosphere and estimated the rate of cold-trapping at the poles using a Monte Carlo technique. The Hg vapor may be lost from the exosphere via ionization, Jeans escape, or re-impact into the surface causing reabsorption.

  1. Groebner Basis Solutions to Satellite Trajectory Control by Pole Placement

    Science.gov (United States)

    Kukelova, Z.; Krsek, P.; Smutny, V.; Pajdla, T.

    2013-09-01

    Satellites play an important role, e.g., in telecommunication, navigation and weather monitoring. Controlling their trajectories is an important problem. In [1], an approach to the pole placement for the synthesis of a linear controller has been presented. It leads to solving five polynomial equations in nine unknown elements of the state space matrices of a compensator. This is an underconstrained system and therefore four of the unknown elements need to be considered as free parameters and set to some prior values to obtain a system of five equations in five unknowns. In [1], this system was solved for one chosen set of free parameters with the help of Dixon resultants. In this work, we study and present Groebner basis solutions to this problem of computation of a dynamic compensator for the satellite for different combinations of input free parameters. We show that the Groebner basis method for solving systems of polynomial equations leads to very simple solutions for all combinations of free parameters. These solutions require to perform only the Gauss-Jordan elimination of a small matrix and computation of roots of a single variable polynomial. The maximum degree of this polynomial is not greater than six in general but for most combinations of the input free parameters its degree is even lower. [1] B. Palancz. Application of Dixon resultant to satellite trajectory control by pole placement. Journal of Symbolic Computation, Volume 50, March 2013, Pages 79-99, Elsevier.

  2. Particle acceleration at the magnetic poles of a neutron star

    International Nuclear Information System (INIS)

    Jones, P.B.

    1977-01-01

    The magnetic conversion of a photon in a neutron star magnetosphere near one of the magnetic poles is followed by acceleration of the electron and positron to ultra-relativistic energies. The positron moves along open magnetic flux lines to the light cylinder. The electron incident on the stellar surface produces an electromagnetic shower. Following a comment by Cheng and Ruderman (Astrophys.J.;214:598 (1977)), an order of magnitude estimate has been made of the spectrum of backward moving photons created in the electron shower. The most important source of photons is shown to be the formation of the giant dipole state in Fe 56 . Under the assumption that the surface magnetic flux density exceeds 10 12 G, the photons have, with high probability, mean free paths for magnetic conversion in the magnetosphere of 1 4 cm. An equation for the maximum acceleratin potential has been obtained in a one-dimensional model of pair creation and electron multiplication based on this photon source. The model has been applied to the phenomenon of subpulse drift in pulsars. The plasma accelerated at the magnetic pole has three components; positrons, protons and light nuclei (Z < approximately 6) formed by spallation, and iron group nuclei. Equations determining their relative fluxes have been found. The light nuclei include those with Z = 3 to 5, usually considered to be present in galactic cosmic rays only as a result of the interaction of heavier nuclei with the interstellar medium. (author)

  3. POLE-LIKE STREET FURNITURE DECOMPOSTION IN MOBILE LASER SCANNING DATA

    Directory of Open Access Journals (Sweden)

    F. Li

    2016-06-01

    Full Text Available Automatic semantic interpretation of street furniture has become a popular topic in recent years. Current studies detect street furniture as connected components of points above the street level. Street furniture classification based on properties of such components suffers from large intra class variability of shapes and cannot deal with mixed classes like traffic signs attached to light poles. In this paper, we focus on the decomposition of point clouds of pole-like street furniture. A novel street furniture decomposition method is proposed, which consists of three steps: (i acquirement of prior-knowledge, (ii pole extraction, (iii components separation. For the pole extraction, a novel global pole extraction approach is proposed to handle 3 different cases of street furniture. In the evaluation of results, which involves the decomposition of 27 different instances of street furniture, we demonstrate that our method decomposes mixed classes street furniture into poles and different components with respect to different functionalities.

  4. Pole-Like Street Furniture Decompostion in Mobile Laser Scanning Data

    Science.gov (United States)

    Li, F.; Oude Elberink, S.; Vosselman, G.

    2016-06-01

    Automatic semantic interpretation of street furniture has become a popular topic in recent years. Current studies detect street furniture as connected components of points above the street level. Street furniture classification based on properties of such components suffers from large intra class variability of shapes and cannot deal with mixed classes like traffic signs attached to light poles. In this paper, we focus on the decomposition of point clouds of pole-like street furniture. A novel street furniture decomposition method is proposed, which consists of three steps: (i) acquirement of prior-knowledge, (ii) pole extraction, (iii) components separation. For the pole extraction, a novel global pole extraction approach is proposed to handle 3 different cases of street furniture. In the evaluation of results, which involves the decomposition of 27 different instances of street furniture, we demonstrate that our method decomposes mixed classes street furniture into poles and different components with respect to different functionalities.

  5. The effect of poling conditions on the performance of piezoelectric energy harvesters fabricated by wet chemistry

    KAUST Repository

    Fuentes-Fernandez, Erika Maria-Anai

    2015-03-25

    The effect of poling conditions on the power output of piezoelectric energy harvesters using sol-gel based Pb(Zr0.53,Ti0.47)O3-Pb(Zn1/3,Nb2/3)O3 piezoelectric thin-films has been investigated. A strong correlation was established between the poling efficiency and harvester output. A method based on simple capacitance-voltage measurements is shown to be an effective approach to estimate the power output of harvesters poled under different conditions. The poling process was found to be thermally activated with an activation energy of 0.12 eV, and the optimum poling conditions were identified (200 kV cm-1, 250 °C for 50 min). The voltage output and power density obtained under optimum poling conditions were measured to be 558 V cm-2 and 325 μW cm-2, respectively. © The Royal Society of Chemistry.2015.

  6. Design of an adaptive pole assignment controller for steam generators and its experimental study

    International Nuclear Information System (INIS)

    Na, Man Gyun; No, Hee Cheon

    1992-01-01

    An adaptive observer is designed that both parameters and state variables of the steam generator are estimated simultaneously. A pole assignment controller is derived on the basis of the adaptive observer. The characteristics of the overall closed-loop control system can be expressed in terms of its poles, assigned poles. The troublesome tuning procedure of the P-I controller is reduced to the determination of the desired poles only. The proposed algorithm is compared with the conventional P-I controller through numerical simulation. Also, the adaptive pole assignment controller is studied experimentally by implementing it to the mock-up of the nuclear steam generator. The adaptive pole assignment controller shows better responses than the P-l controller does. (Author)

  7. Field analysis and enhancement of multi-pole magnetic components fabricated on printed circuit board

    International Nuclear Information System (INIS)

    Chiu, K.-C.; Chen, C.-S.

    2007-01-01

    A multi-pole magnetic component magnetized with a fine magnetic pole pitch of less than 1 mm is very difficult to achieve by using traditional methods. Moreover, it requires a precise mechanical process and a complicated magnetization system. Different fine magnetic pole pitches of 300, 350 and 400 μm have been accomplished on 9-pole magnetic components through the printed circuit board (PCB) manufacturing technology. Additionally, another fine magnetic pole pitch of 500 μm was also fabricated on a dual-layered (DL) wire circuit structure to investigate the field enhancement. After measurements, a gain factor of 1.37 was obtained in the field strength. The field variations among different magnetic pole pitches were analyzed in this paper

  8. Lower Pole Calyceal Stone and Lithotripsy are Issues with Clearance Fact or Reality?

    Directory of Open Access Journals (Sweden)

    M. Hammad Ather

    2013-12-01

    Full Text Available The lower pole calyceal (LPC stone continues to be an enigma. The complex anatomy of the lower pole collecting system, along with other factors like acute pelvi calyceal angle and narrow and long infundibulum, are some of the complicating factors affecting stone clearance. There have been many studies assessing the impact of collecting system anatomy and most conclude that the complex anatomy of the lower pole collecting system does impact the overall stone-free rate.

  9. Iron Pole Shape Optimization of IPM Motors Using an Integrated Method

    Directory of Open Access Journals (Sweden)

    JABBARI, A.

    2010-02-01

    Full Text Available An iron pole shape optimization method to reduce cogging torque in Interior Permanent Magnet (IPM motors is developed by using the reduced basis technique coupled by finite element and design of experiments methods. Objective function is defined as the minimum cogging torque. The experimental design of Taguchi method is used to build the approximation model and to perform optimization. This method is demonstrated on the rotor pole shape optimization of a 4-poles/24-slots IPM motor.

  10. Phytochemical screening, proximate analysis and acute toxicity ...

    African Journals Online (AJOL)

    Phytochemical screening results indicate the presence of saponins, flavonoids, phytosterols and phenols. Acute toxicity study showed there was no mortality at 8000 mg/kg of the extract. The results indicate that the plant is rich in phytochemicals and is relatively safe. Key words: Phytochemicals, acute toxicity, proximate ...

  11. PROXIMATE AND ELEMENTAL COMPOSITION OF WHITE GRUBS

    African Journals Online (AJOL)

    DR. AMINU

    This study determined the proximate and mineral element composition of whole white grubs using standard methods of analysis. ... and 12.75 ± 3.65% respectively. Mineral contents of white grub in terms of relative concentration .... of intracellular Ca, bone mineralization, blood coagulation, and plasma membrane potential ...

  12. Phytochemical Screening and Proximate Analysis of Newbouldia ...

    African Journals Online (AJOL)

    The study was conducted to assess the phytochemical and proximate composition of Newboudia laevis leaves and Allium sativum bulb extracts. The leaves and bulbs extracts were analyzed for their chemical composition and antinutritional factors (ANFs) which include moisture, crude protein, crude fat, crude fiber, total ash ...

  13. Phytochemical Screening, Proximate and Mineral Composition of ...

    African Journals Online (AJOL)

    Leaves of sweet potato (Ipomoea batatas) grown in Tepi area was studied for their class of phytochemicals, mineral and proximate composition using standard analytical methods. The phytochemical screening revealed the presence of alkaloids, flavonoid, terpenoids, saponins, quinones, phenol, tannins, amino acid and ...

  14. Phytochemical screening, proximate and elemental analysis of ...

    African Journals Online (AJOL)

    Citrus sinensis was screened for its phytochemical composition and was evaluated for the proximate and elemental analysis. The phytochemical analysis indicated the presence of reducing sugar, saponins, cardiac glycosides, tannins and flavonoids. The elemental analysis indicated the presence of the following mineral ...

  15. Modified Koyanagi Technique in Management of Proximal ...

    African Journals Online (AJOL)

    xp

    Modified Koyanagi Technique in Management of Proximal Hypospadias. Adham Elsaied, Basem Saied, and Mohammed El- ... All operations were performed by the authors,using fine instruments and under 3.5X loupe ... the other needed an operation to close the fistula six months later. The case with meatal recession had ...

  16. Proximity focusing RICH with TOF capabilities

    International Nuclear Information System (INIS)

    Korpar, S.; Adachi, I.; Fujita, K.; Fukushima, T.; Gorisek, A.; Hayashi, D.; Iijima, T.; Ikado, T.; Ishikawa, T.; Kawai, H.; Kozakai, Y.; Krizan, P.; Kuratani, A.; Mazuka, Y.; Nakagawa, T.; Nishida, S.; Ogawa, S.; Pestotnik, R.; Seki, T.; Sumiyoshi, T.; Tabata, M.; Unno, Y.

    2007-01-01

    A proximity focusing RICH counter with a multi-channel micro-channel plate (MCP) PMT was tested as a time-of-flight counter. Cherenkov photons emitted in the radiator medium as well as in the entrance window of the PMT were used for the time-of-flight measurement, and an excellent performance of the counter could be demonstrated

  17. Proximate composition and mycological characterization of peanut ...

    African Journals Online (AJOL)

    SARAH

    2013-12-30

    Dec 30, 2013 ... ABSTRACT. Objective: The aim of this work was to contribute to the food safety of Ivorian consumers by investigating the proximate composition and the toxic fungal contamination of peanut butters offered for retail sale on the different markets of Abidjan. Methodology and results: Peanut butter samples (45) ...

  18. Prosthetic replacement for proximal humeral fractures.

    Science.gov (United States)

    Kontakis, George; Tosounidis, Theodoros; Galanakis, Ioannis; Megas, Panagiotis

    2008-12-01

    The ideal management of complex proximal humeral fractures continues to be debatable. Evolution of proximal humeral fracture management, during the past decade, led to the implementation of many innovations in surgical treatment. Even though the pendulum of treatment seems to swing towards new trends such as locked plating, hemiarthroplasty remains a valid and reliable option that serves the patient's needs well. Hemiarthroplasty is indicated for complex proximal humeral fractures in elderly patients with poor bone stock and when internal fixation is difficult or unreliable. Hemiarthroplasty provides a better result when it is performed early post-injury. Stem height, retroversion and tuberosity positioning are technical aspects of utmost importance. Additionally reverse total shoulder arthroplasty is an alternative new modality that can be used as a primary solution in selected patients with proximal humeral fracture treatment. Failed hemiarthroplasty and fracture sequelae can be successfully managed with reverse total shoulder arthroplasty. Individual decision-making and tailored treatment that takes into consideration the personality of the fracture and the patient's characteristics should be used.

  19. Phytochemistry and proximate composition of ginger ( Zingiber ...

    African Journals Online (AJOL)

    The results of the phytochemical screening showed that alkaloids, carbohydrates, glycosides, proteins, saponins, steroids, flavonoids and terpenoids were present, while reducing sugars, tannins, oils and acid compounds were absent. Similarly, the results of the proximate analysis of the rhizome showed that ginger ...

  20. Disability occurrence and proximity to death

    NARCIS (Netherlands)

    Klijs, Bart; Mackenbach, Johan P.; Kunst, Anton E.

    2010-01-01

    Purpose. This paper aims to assess whether disability occurrence is related more strongly to proximity to death than to age. Method. Self reported disability and vital status were available from six annual waves and a subsequent 12-year mortality follow-up of the Dutch GLOBE longitudinal study.

  1. Proximate composition, bread characteristics and sensory ...

    African Journals Online (AJOL)

    This study was carried out to investigate proximate composition, bread characteristics and sensory evaluation of cocoyam-wheat composite breads at different levels of cocoyam flour substitution for human consumption.A whole wheat bread (WWB) and cocoyam-composite breads (CCB1,CCB 2 and CCB 3) were prepared ...

  2. Time domain oscillating poles: Stability redefined in Memristor based Wien-oscillators

    KAUST Repository

    Talukdar, Abdul Hafiz Ibne

    2012-07-28

    Traditionally, the necessary and sufficient condition for any system to be oscillating is that its poles are located on the imaginary (jω) axis. In this paper, for the first time, we have shown that systems can oscillate with time-domain oscillating poles. The idea is verified using a Memristor based Wien oscillator. Sustained oscillations are observed without having the poles of the system fixed on the imaginary axis and the oscillating behavior of the system poles is reported. The oscillating resistance and triangular shape of FFT are also demonstrated with mathematical reasoning and simulation results to support the unusual and surprising characteristics. © 2009 IEEE.

  3. Texture of poled tetragonal PZT detected by synchrotron X-ray diffraction and micromechanics analysis

    International Nuclear Information System (INIS)

    Hall, D.A.; Steuwer, A.; Cherdhirunkorn, B.; Withers, P.J.; Mori, T.

    2005-01-01

    The texture and lattice elastic strain due to electrical poling of tetragonal PZT (lead zirconate titanate) ceramics have been measured using high energy synchrotron X-ray diffraction. It is shown that XRD peak intensity ratios associated with crystal planes of the form {002}, {112} and {202} exhibit a linear dependence on cos-bar 2 Ψ, where Ψ represents the orientation angle between the plane normal and the macroscopic poling axis. The observed dependence of texture and lattice strain on the grain orientation can be understood on the basis that the macroscopic strain due to poling is the average of the poling strains of all the individual grains

  4. Reuse of poles treated with CCA; CCA-kyllaestettyjen puupylvaeiden uudelleenkaeyttoe

    Energy Technology Data Exchange (ETDEWEB)

    Lehmus, E. [Vtt Building and Transport, Espoo (Finland)

    2005-07-01

    This study investigated the feasibility of re-using utility poles or parts of poles for structural use in construction. There are more than 10 million poles in Finland and about 200 000 poles will be removed from service yearly during the next few years. The directive 2003/2/EY will restrict the use of poles treated with CCA. This will change the practice that the energy and telecommunication companies have given the removed poles to the land owners. The present study launched by the Technical Research Centre of Finland (VTT) was carried out to determine the technical condition of CCA impregnated poles removed from service and the concentration levels and leaching of remaining preservatives. To summarize the results of the tests, it is safe to say that re-use of recovered poles of 30 to 50 years of age is possible. Both the preservative concentrations and strength/load-bearing capacity are high enough to allow the use of the poles as load-bearing structures. (orig.)

  5. A 15-pole high temperature superconductor filter for radar applications

    Science.gov (United States)

    Yu, Xiao; Xi, Weibin; Wu, Songtao

    2018-06-01

    This paper presents a compact and high first harmonic frequency resonator. The characteristics of this resonator are theoretically analyzed. A highly selective 15-pole Chebyshev high temperature superconducting ultra-high frequency narrowband filter for radar applications was fabricated by using this resonator. The filter has a center frequency of 495 MHz and a fractional bandwidth of 1%. The first harmonic frequency is more than 3.3 times the fundamental frequency. The measured filter shows excellent selectivity, better than 85 dB/1 MHz skirt slopes, and more than 85 dB of rejection at 497.5 MHz from the band edge. The filter was fabricated on a 2 inch YBCO thin film with a 0.5 mm thick MgO substrate. The experimental results are consistent with the simulations.

  6. One-dimensional thermodynamical model for poling of ferroelectric ceramics

    International Nuclear Information System (INIS)

    Bassiouny, E.

    1990-11-01

    In this work, we use a model developed to deduce a one-dimensional model for the description of the poling of ferroelectric ceramics. This is built within the scheme of the thermodynamical theory of internal variables. The model produces both plastic and electric hysteresis effects in the form of ''plasticity'', i.e., rate-independent evolution equations for the plastic strain, and the residual electric polarization and both mechanical and electric hardenings. The influence of stresses on ferroelectric hysteresis loops through piezoelectricity and electrostriction is a natural outcome of this model. Some simple experimental methods for the determination of the material coefficients of the considered ceramics are suggested. (author). 21 refs, 3 figs

  7. THE SPITZER-WISE SURVEY OF THE ECLIPTIC POLES

    International Nuclear Information System (INIS)

    Jarrett, T. H.; Masci, F.; Cutri, R. M.; Marsh, K.; Padgett, D.; Tsai, C. W.; Cohen, M.; Wright, E.; Petty, S.; Stern, D.; Eisenhardt, P.; Mainzer, A.; Ressler, M.; Benford, D.; Blain, A.; Carey, S.; Surace, J.; Lonsdale, C.; Skrutskie, M.; Stanford, S.

    2011-01-01

    We have carried out a survey of the north and south ecliptic poles, EP-N and EP-S, respectively, with the Spitzer Space Telescope and the Wide-field Infrared Survey Explorer (WISE). The primary objective was to cross-calibrate WISE with the Spitzer and Midcourse Space Experiment (MSX) photometric systems by developing a set of calibration stars that are common to these infrared missions. The ecliptic poles were continuous viewing zones for WISE due to its polar-crossing orbit, making these areas ideal for both absolute and internal calibrations. The Spitzer IRAC and MIPS imaging survey covers a complete area of 0.40 deg 2 for the EP-N and 1.28 deg 2 for the EP-S. WISE observed the whole sky in four mid-infrared bands, 3.4, 4.6, 12, and 22 μm, during its eight-month cryogenic mission, including several hundred ecliptic polar passages; here we report on the highest coverage depths achieved by WISE, an area of ∼1.5 deg 2 for both poles. Located close to the center of the EP-N, the Sy-2 galaxy NGC 6552 conveniently functions as a standard calibrator to measure the red response of the 22 μm channel of WISE. Observations from Spitzer-IRAC/MIPS/IRS-LL and WISE show that the galaxy has a strong red color in the mid-infrared due to star-formation and the presence of an active galactic nucleus (AGN), while over a baseline >1 year the mid-IR photometry of NGC 6552 is shown to vary at a level less than 2%. Combining NGC 6552 with the standard calibrator stars, the achieved photometric accuracy of the WISE calibration, relative to the Spitzer and MSX systems, is 2.4%, 2.8%, 4.5%, and 5.7% for W1 (3.4 μm), W2 (4.6 μm), W3 (12 μm), and W4 (22 μm), respectively. The WISE photometry is internally stable to better than 0.1% over the cryogenic lifetime of the mission. The secondary objective of the Spitzer-WISE Survey was to explore the poles at greater flux-level depths, exploiting the higher angular resolution Spitzer observations and the exceptionally deep (in total

  8. Performance of claw-poled PM-stepping motor

    International Nuclear Information System (INIS)

    Liu, C.P.; Jeng, G.R.; Chen, W.C.; Tsai, M.C.; Wu, K.T.; Yao, Y.D.

    2007-01-01

    Present work is to analyze the performance of a permanent-magnetic (PM) stepping motor with claw poles by using the magnetic-circuit simulation technique. In this paper, we calculate the torque characteristics of the motor, such as the detent and the holding torques, and the step-position error by changing the gap between the upper and the lower stators and the staggered angle between the two stators. Through comparison of numerical data with experiment measurements, we found that the detent torque could be effectively reduced by increasing the stator-to-stator gap and further by decreasing the step-position error. Furthermore, the holding torque could be unchanged as the stator assemblage changed; however, it would be degenerated under the condition of low magnetization

  9. Unitary pole approximations and expansions in few-body systems

    International Nuclear Information System (INIS)

    Casel, A.; Haberzettl, H.; Sandhas, W.

    1982-01-01

    The unitary pole approximations or expansions of the two-body subsystem operators are well known, and particularly efficient and practical, methods to reduce the three-body problem to an effective two-body theory. In the present investigation we develop generalizations of these approximation techniques to the subsystem amplitudes of problems with higher particle numbers. They are based on the expansion of effective potentials which, in contrast to the genuine two-body interactions, are now energy dependent. Despite this feature our generalizations require only energy independent form factors, thus preserving one of the essential advantages of the genuine two-body approach. The application of these techniques to the four-body case is discussed in detail

  10. Lunar South Pole space water extraction and trucking system

    International Nuclear Information System (INIS)

    Zuppero, A.; Zupp, G.; Schnitzler, B.; Larson, T.K.; Rice, J.W.

    1998-03-01

    This concept proposes to use thermal processes alone to extract water from the lunar South Pole and launch payloads to low lunar orbit. Thermal steam rockets would use water propellant for space transportation. The estimated mass of a space water tanker powered by a nuclear heated steam rocket suggests it can be designed for launch in the Space Shuttle bay. The performance depends on the feasibility of a nuclear reactor rocket engine producing steam at 1,100 degrees Kelvin, with a power density of 150 Megawatts per ton of rocket, and operating for thousands of 20 minute cycles. An example uses reject heat from a small nuclear electric power supply to melt 17,800 tons per year of lunar ice. A nuclear heated steam rocket would use the propellant water to launch and deliver 3,800 tons of water per year to a 100 km low lunar orbit

  11. Ruthenium therapy of choroidal melanomas of the posterior pole

    International Nuclear Information System (INIS)

    Langmann, G.; Faschinger, C.; Langmann, A.; Poier, E.

    1992-01-01

    The indications for conservative treatment of intraocular melanomas of the posterior pole with radioactive plaques are controversial. Melanomas located at the macula or adjacent to the fovea are regarded as relative contraindications for conservative treatment. Three melanomas of the macula have been treated at our department meanwhile. The tumor elevation ranged between 3.5 and 6 mm, the distance to the fovea between 0.5 and 2 dd. An average radiation dosage between 130 and 160 Gy was delivered to the apex of the tumors. The duration of observation was between 12 months to 4 years. The tumor regression was satisfactory in all 3 cases, additional photocoagulation was necessary in one case of incomplete tumor regression. Pretreatment visual acuity ranged between 0.8 and 0.1, posttreatment visual acuity between 0.8 and 0.25. In one case we observed a local radiation vasculopathy. General examination did not reveal any signs of metastases. (authors)

  12. Method of regulating magnetic field of magnetic pole center

    International Nuclear Information System (INIS)

    Watanabe, Masao; Yamada, Teruo; Kato, Norihiko; Toda, Yojiro; Kaneda, Yasumasa.

    1978-01-01

    Purpose: To provide the subject method comprising using a plurality of magnetic metal pieces having different thicknesses, regulating very easily symmetry of the field of the magnetic pole center depending upon the combination of said metal pieces, thereby obtaining a magnetic field of high precision. Method: The regulation of magnetic field at the central part of the magnetic field is not depending only upon processing of the center plug, axial movement of trim coil and ion source but by providing a magnetic metal piece such as an iron ring, primary higher harmonics of the field at the center of the magnetic field can be regulated simply while the position of the ion source slit is on the equipotential surface in the field. (Yoshihara, H.)

  13. Patterned piezo-, pyro-, and ferroelectricity of poled polymer electrets

    International Nuclear Information System (INIS)

    Qiu, Xunlin

    2010-01-01

    Polymers with strong piezo-, pyro-, and ferroelectricity are attractive for a wide range of applications. In particular, semicrystalline ferroelectric polymers are suitable for a large variety of piezo- and pyroelectric transducers or sensors, while amorphous polymers containing chromophore molecules are particularly interesting for photonic devices. Recently, a new class of polymer materials has been added to this family: internally charged cellular space-charge polymer electrets (so-called “ferroelectrets”), whose piezoelectricity can be orders of magnitude higher than that of conventional ferroelectric polymers. Suitable patterning of these materials leads to improved or unusual macroscopic piezo-, pyro-, and ferroelectric or nonlinear optical properties that may be particularly useful for advanced transducer or waveguide applications. In the present paper, the piezo-, pyro-, and ferroelectricity of poled polymers is briefly introduced, an overview on the preparation of polymer electrets with patterned piezo-, pyro-, and ferroelectricity is provided and a survey of selected applications is presented.

  14. The 'Pole Nucleaire Bourgogne' for developing the nuclear components industry

    International Nuclear Information System (INIS)

    Kottmann, G.

    2012-01-01

    The 'Pole Nucleaire Bourgogne' (PNB) is a high-technology and heavy industries cluster in Burgundy with an international calling. It aims at innovating, educating and federating in order to place the French nuclear industry in a leading position. PNB gathers 76 small-, and medium-sized enterprises, most of them operating in the metal sector, in design and in the control/measuring sector. The aim of PNB is to make enterprises work and cooperate on specific topics according to their sectors of activities and their skills. PNB has identified 3 domains of strategical innovations: -) ecological manufacturing and durability of heavy components, -) controls for high performance components, and -) maintenance and dismantling techniques in hostile environments. The various industry sectors represented in PNB allows a cross-fertilization between high-tech industries (aeronautics, energy, transportation)

  15. Inspection of Pole-Like Structures Using a Visual-Inertial Aided VTOL Platform with Shared Autonomy.

    Science.gov (United States)

    Sa, Inkyu; Hrabar, Stefan; Corke, Peter

    2015-09-02

    This paper presents an algorithm and a system for vertical infrastructure inspection using a vertical take-off and landing (VTOL) unmanned aerial vehicle and shared autonomy. Inspecting vertical structures such as light and power distribution poles is a difficult task that is time-consuming, dangerous and expensive. Recently, micro VTOL platforms (i.e., quad-, hexa- and octa-rotors) have been rapidly gaining interest in research, military and even public domains. The unmanned, low-cost and VTOL properties of these platforms make them ideal for situations where inspection would otherwise be time-consuming and/or hazardous to humans. There are, however, challenges involved with developing such an inspection system, for example flying in close proximity to a target while maintaining a fixed stand-off distance from it, being immune to wind gusts and exchanging useful information with the remote user. To overcome these challenges, we require accurate and high-update rate state estimation and high performance controllers to be implemented onboard the vehicle. Ease of control and a live video feed are required for the human operator. We demonstrate a VTOL platform that can operate at close-quarters, whilst maintaining a safe stand-off distance and rejecting environmental disturbances. Two approaches are presented: Position-Based Visual Servoing (PBVS) using an Extended Kalman Filter (EKF) and estimator-free Image-Based Visual Servoing (IBVS). Both use monocular visual, inertia, and sonar data, allowing the approaches to be applied for indoor or GPS-impaired environments. We extensively compare the performances of PBVS and IBVS in terms of accuracy, robustness and computational costs. Results from simulations Sensors 2015, 15 22004 and indoor/outdoor (day and night) flight experiments demonstrate the system is able to successfully inspect and circumnavigate a vertical pole.

  16. Inspection of Pole-Like Structures Using a Visual-Inertial Aided VTOL Platform with Shared Autonomy

    Directory of Open Access Journals (Sweden)

    Inkyu Sa

    2015-09-01

    Full Text Available This paper presents an algorithm and a system for vertical infrastructure inspection using a vertical take-off and landing (VTOL unmanned aerial vehicle and shared autonomy. Inspecting vertical structures such as light and power distribution poles is a difficult task that is time-consuming, dangerous and expensive. Recently, micro VTOL platforms (i.e., quad-, hexa- and octa-rotors have been rapidly gaining interest in research, military and even public domains. The unmanned, low-cost and VTOL properties of these platforms make them ideal for situations where inspection would otherwise be time-consuming and/or hazardous to humans. There are, however, challenges involved with developing such an inspection system, for example flying in close proximity to a target while maintaining a fixed stand-off distance from it, being immune to wind gusts and exchanging useful information with the remote user. To overcome these challenges, we require accurate and high-update rate state estimation and high performance controllers to be implemented onboard the vehicle. Ease of control and a live video feed are required for the human operator. We demonstrate a VTOL platform that can operate at close-quarters, whilst maintaining a safe stand-off distance and rejecting environmental disturbances. Two approaches are presented: Position-Based Visual Servoing (PBVS using an Extended Kalman Filter (EKF and estimator-free Image-Based Visual Servoing (IBVS. Both use monocular visual, inertia, and sonar data, allowing the approaches to be applied for indoor or GPS-impaired environments. We extensively compare the performances of PBVS and IBVS in terms of accuracy, robustness and computational costs. Results from simulations Sensors 2015, 15 22004 and indoor/outdoor (day and night flight experiments demonstrate the system is able to successfully inspect and circumnavigate a vertical pole.

  17. Inspection of Pole-Like Structures Using a Visual-Inertial Aided VTOL Platform with Shared Autonomy

    Science.gov (United States)

    Sa, Inkyu; Hrabar, Stefan; Corke, Peter

    2015-01-01

    This paper presents an algorithm and a system for vertical infrastructure inspection using a vertical take-off and landing (VTOL) unmanned aerial vehicle and shared autonomy. Inspecting vertical structures such as light and power distribution poles is a difficult task that is time-consuming, dangerous and expensive. Recently, micro VTOL platforms (i.e., quad-, hexa- and octa-rotors) have been rapidly gaining interest in research, military and even public domains. The unmanned, low-cost and VTOL properties of these platforms make them ideal for situations where inspection would otherwise be time-consuming and/or hazardous to humans. There are, however, challenges involved with developing such an inspection system, for example flying in close proximity to a target while maintaining a fixed stand-off distance from it, being immune to wind gusts and exchanging useful information with the remote user. To overcome these challenges, we require accurate and high-update rate state estimation and high performance controllers to be implemented onboard the vehicle. Ease of control and a live video feed are required for the human operator. We demonstrate a VTOL platform that can operate at close-quarters, whilst maintaining a safe stand-off distance and rejecting environmental disturbances. Two approaches are presented: Position-Based Visual Servoing (PBVS) using an Extended Kalman Filter (EKF) and estimator-free Image-Based Visual Servoing (IBVS). Both use monocular visual, inertia, and sonar data, allowing the approaches to be applied for indoor or GPS-impaired environments. We extensively compare the performances of PBVS and IBVS in terms of accuracy, robustness and computational costs. Results from simulations and indoor/outdoor (day and night) flight experiments demonstrate the system is able to successfully inspect and circumnavigate a vertical pole. PMID:26340631

  18. Determination of regional Euler pole parameters for Eastern Austria

    Science.gov (United States)

    Umnig, Elke; Weber, Robert; Schartner, Matthias; Brueckl, Ewald

    2017-04-01

    The horizontal motion of lithospheric plates can be described as rotations around a rotation axes through the Earth's center. The two possible points where this axes intersects the surface of the Earth are called Euler poles. The rotation is expressed by the Euler parameters in terms of angular velocities together with the latitude and longitude of the Euler pole. Euler parameters were calculated from GPS data for a study area in Eastern Austria. The observation network is located along the Mur-Mürz Valley and the Vienna Basin. This zone is part of the Vienna Transfer Fault, which is the major fault system between the Eastern Alps and the Carpathians. The project ALPAACT (seismological and geodetic monitoring of ALpine-PAnnonian ACtive Tectonics) investigated intra plate tectonic movements within the Austrian part in order to estimate the seismic hazard. Precise site coordinate time series established from processing 5 years of GPS observations are available for the regional network spanning the years from 2010.0 to 2015.0. Station velocities with respect to the global reference frame ITRF2008 have been computed for 23 sites. The common Euler vector was estimated on base of a subset of reliable site velocities, for stations directly located within the area of interest. In a further step a geokinematic interpretation shall be carried out. Therefore site motions with respect to the Eurasian Plate are requested. To obtain this motion field different variants are conceivable. In a simple approach the mean ITRF2008 velocity of IGS site GRAZ can be adopted as Eurasian rotational velocity. An improved alternative is to calculate site-specific velocity differences between the Euler rotation and the individual site velocities. In this poster presentation the Euler parameters, the residual motion field as well as first geokinematic interpretation results are presented.

  19. Effect of materials and manufacturing on the bending stiffness of vaulting poles

    Science.gov (United States)

    Davis, C. L.; Kukureka, S. N.

    2012-09-01

    The increase in the world record height achieved in pole vaulting can be related to the improved ability of the athletes, in terms of their fitness and technique, and to the change in materials used to construct the pole. For example in 1960 there was a change in vaulting pole construction from bamboo to glass fibre reinforced polymer (GFRP) composites. The lighter GFRP pole enabled the athletes to have a faster run-up, resulting in a greater take-off speed, giving them more kinetic energy to convert into potential energy and hence height. GFRP poles also have a much higher failure stress than bamboo, so the poles were engineered to bend under the load of the athlete, thereby storing elastic strain energy that can be released as the pole straightens, resulting in greater energy efficiency. The bending also allowed athletes to change their vaulting technique from a style that involved the body remaining almost upright during the vault to one where the athlete goes over the bar with their feet upwards. Modern vaulting poles can be made from GFRP and/or carbon fibre reinforced polymer (CFRP) composites. The addition of carbon fibres maintains the mechanical properties of the pole, but allows a reduction in the weight. The number and arrangement of the fibres determines the mechanical properties, in particular the bending stiffness. Vaulting poles are also designed for an individual athlete to take into account each athlete’s ability and physical characteristics. The poles are rated by ‘weight’ to allow athletes to select an appropriate pole for their ability. This paper will review the development of vaulting poles and the requirements to maximize performance. The properties (bending stiffness and pre-bend) and microstructure (fibre volume fraction and lay-up) of typical vaulting poles will be discussed. Originally published as Davis C L and Kukureka S N (2004) Effect of materials and manufacturing on the bending stiffness of vaulting poles The Engineering of

  20. Proximal tubular hypertrophy and enlarged glomerular and proximal tubular urinary space in obese subjects with proteinuria.

    Directory of Open Access Journals (Sweden)

    Ana Tobar

    Full Text Available BACKGROUND: Obesity is associated with glomerular hyperfiltration, increased proximal tubular sodium reabsorption, glomerular enlargement and renal hypertrophy. A single experimental study reported an increased glomerular urinary space in obese dogs. Whether proximal tubular volume is increased in obese subjects and whether their glomerular and tubular urinary spaces are enlarged is unknown. OBJECTIVE: To determine whether proximal tubules and glomerular and tubular urinary space are enlarged in obese subjects with proteinuria and glomerular hyperfiltration. METHODS: Kidney biopsies from 11 non-diabetic obese with proteinuria and 14 non-diabetic lean patients with a creatinine clearance above 50 ml/min and with mild or no interstitial fibrosis were retrospectively analyzed using morphometric methods. The cross-sectional area of the proximal tubular epithelium and lumen, the volume of the glomerular tuft and of Bowman's space and the nuclei number per tubular profile were estimated. RESULTS: Creatinine clearance was higher in the obese than in the lean group (P=0.03. Proteinuria was similarly increased in both groups. Compared to the lean group, the obese group displayed a 104% higher glomerular tuft volume (P=0.001, a 94% higher Bowman's space volume (P=0.003, a 33% higher cross-sectional area of the proximal tubular epithelium (P=0.02 and a 54% higher cross-sectional area of the proximal tubular lumen (P=0.01. The nuclei number per proximal tubular profile was similar in both groups, suggesting that the increase in tubular volume is due to hypertrophy and not to hyperplasia. CONCLUSIONS: Obesity-related glomerular hyperfiltration is associated with proximal tubular epithelial hypertrophy and increased glomerular and tubular urinary space volume in subjects with proteinuria. The expanded glomerular and urinary space is probably a direct consequence of glomerular hyperfiltration. These effects may be involved in the pathogenesis of obesity

  1. SINA: A test system for proximity fuses

    Science.gov (United States)

    Ruizenaar, M. G. A.

    1989-04-01

    SINA, a signal generator that can be used for testing proximity fuses, is described. The circuitry of proximity fuses is presented; the output signal of the RF circuit results from a mixing of the emitted signal and received signal that is Doppler shifted in frequency by the relative motion of the fuse with respect to the reflecting target of surface. With SINA, digitized and stored target and clutter signals (previously measured) can be transformed to Doppler signals, for example during a real flight. SINA can be used for testing fuse circuitry, for example in the verification of results of computer simulations of the low frequency Doppler signal processing. The software of SINA and its use are explained.

  2. Stellar population samples at the galactic poles. IV. Luminosity function for the M-type dwarfs at the South Pole

    International Nuclear Information System (INIS)

    Eggen, O.J.

    1976-01-01

    The (UBVRI) photometry of all M dwarfs which are within 10degree of the South Galactic Pole and brighter than visual magnitude 15, and which have annual proper motions greater than 0/sup prime/./sub /096, are discussed. The observations themselves are listed and discussed in a recent Astrophysical Journal Supplement. The luminosity function is found to be very similar, in the overlapping sections, to that previously derived spectrophotometrically from the M stars near the Sun, and the extension to M/subV/ near +13 mag indicates that this luminosity is near the peak of that function. No support is found in these data for the recently suggested superabundance of low velocity M stars near the Sun

  3. Isolated Proximal Tibiofibular Dislocation during Soccer

    Directory of Open Access Journals (Sweden)

    Casey Chiu

    2015-01-01

    Full Text Available Proximal tibiofibular dislocations are rarely encountered in the Emergency Department (ED. We present a case involving a man presenting to the ED with left knee pain after making a sharp left turn on the soccer field. His physical exam was only remarkable for tenderness over the lateral fibular head. His X-rays showed subtle abnormalities of the tibiofibular joint. The dislocation was reduced and the patient was discharged from the ED with orthopedic follow-up.

  4. Superconducting proximity effect in topological materials

    Science.gov (United States)

    Reeg, Christopher R.

    In recent years, there has been a renewed interest in the proximity effect due to its role in the realization of topological superconductivity. In this dissertation, we discuss several results that have been obtained in the field of proximity-induced superconductivity and relate the results to the search for Majorana fermions. First, we show that repulsive electron-electron interactions can induce a non-Majorana zero-energy bound state at the interface between a conventional superconductor and a normal metal. We show that this state is very sensitive to disorder, owing to its lack of topological protection. Second, we show that Rashba spin-orbit coupling, which is one of the key ingredients in engineering a topological superconductor, induces triplet pairing in the proximity effect. When the spin-orbit coupling is strong (i.e., when the characteristic energy scale for spin-orbit coupling is comparable to the Fermi energy), the induced singlet and triplet pairing amplitudes can be comparable in magnitude. Finally, we discuss how the size of the proximity-induced gap, which appears in a low-dimensional material coupled to a superconductor, evolves as the thickness of the (quasi-)low-dimensional material is increased. We show that the induced gap can be comparable to the bulk energy gap of the underlying superconductor in materials that are much thicker than the Fermi wavelength, even in the presence of an interfacial barrier and strong Fermi surface mismatch. This result has important experimental consequences for topological superconductivity, as a sizable gap is required to isolate and detect the Majorana modes.

  5. [Proximity and breastfeeding at the maternity hospital].

    Science.gov (United States)

    Fradin-Charrier, Anne-Claire

    2015-01-01

    The establishment of breastfeeding, as well as its duration, are facilitated through the proximity of the mother with her new baby. However, in maternity hospitals, breastfeeding mothers very often leave their baby in the nursery at night time. A study carried out in 2014 in several maternity hospitals put forward suggestions and highlighted areas to improve in everyday practice. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  6. Regge poles and Mandelstam representation in potential scattering; Poles de regge et representation de Mandelstam en theorie du potentiel

    Energy Technology Data Exchange (ETDEWEB)

    Bessis, D [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-03-01

    We deal with the scattering of two spinless particles interacting by a superposition of Yukawa potentials. We first obtain an upper bound for the scattering amplitude for simultaneous complex values of energy and angular momentum. We then show that the Regge poles remain confined in small domains of the complex angular momentum plane, we study the variation of these domains when the energy (complex) varies. These first results allow us to deduce an upper bound for the double spectral function, this upper bound is used to rigorously show that the Schroedinger equation implies the Mandelstam representation for the type of potentials we deal with. Finally, the problem of subtractions is entirely solved, showing that the Mellin transform of the double spectral function can be analytically continued into the different simple spectral functions. (author) [French] On traite de la diffusion de deux particules sans spin interagissant par l'intermediaire d'une superposition de potentiels de Yukawa. Nous obtenons tout d'abord une majorante pour l'amplitude de diffusion pour des valeurs simultanement complexes de l'energie et du moment cinetique. On montre alors que les Poles de Regge restent confines dans des domaines restreints du plan complexe du moment cinetique, domaines dont nous etudions la variation pour des valeurs complexes de l'energie. Ces premiers resultats nous permettent alors de deduire une majorante pour la fonction spectrale double, majorante qui est utilisee pour demontrer rigoureusement que l'equation de Schroedinger implique la representation de Mandelstam pour la classe des potentiels envisages. Enfin le probleme des soustractions est entierement resolu, en montrant que la transformee de Mellin de la fonction spectrale double se prolonge analytiquement dans les diverses fonctions spectrales simples. (auteur)

  7. Proximity effects in topological insulator heterostructures

    International Nuclear Information System (INIS)

    Li Xiao-Guang; Wu Guang-Fen; Zhang Gu-Feng; Culcer Dimitrie; Zhang Zhen-Yu; Chen Hua

    2013-01-01

    Topological insulators (TIs) are bulk insulators that possess robust helical conducting states along their interfaces with conventional insulators. A tremendous research effort has recently been devoted to Tl-based heterostructures, in which conventional proximity effects give rise to a series of exotic physical phenomena. This paper reviews our recent studies on the potential existence of topological proximity effects at the interface between a topological insulator and a normal insulator or other topologically trivial systems. Using first-principles approaches, we have realized the tunability of the vertical location of the topological helical state via intriguing dual-proximity effects. To further elucidate the control parameters of this effect, we have used the graphene-based heterostructures as prototypical systems to reveal a more complete phase diagram. On the application side of the topological helical states, we have presented a catalysis example, where the topological helical state plays an essential role in facilitating surface reactions by serving as an effective electron bath. These discoveries lay the foundation for accurate manipulation of the real space properties of the topological helical state in TI-based heterostructures and pave the way for realization of the salient functionality of topological insulators in future device applications. (topical review - low-dimensional nanostructures and devices)

  8. [Augmentation technique on the proximal humerus].

    Science.gov (United States)

    Scola, A; Gebhard, F; Röderer, G

    2015-09-01

    The treatment of osteoporotic fractures is still a challenge. The advantages of augmentation with respect to primary in vitro stability and the clinical use for the proximal humerus are presented in this article. In this study six paired human humeri were randomized into an augmented and a non-augmented group. Osteosynthesis was performed with a PHILOS plate (Synthes®). In the augmented group the two screws finding purchase in the weakest cancellous bone were augmented. The specimens were tested in a 3-part fracture model in a varus bending test. The augmented PHILOS plates withstood significantly more load cycles until failure. The correlation to bone mineral density (BMD) showed that augmentation could partially compensate for low BMD. The augmentation of the screws in locked plating in a proximal humerus fracture model is effective in improving the primary stability in a cyclic varus bending test. The targeted augmentation of two particular screws in a region of low bone quality within the humeral head was almost as effective as four screws with twice the amount of bone cement. Screw augmentation combined with a knowledge of the local bone quality could be more effective in enhancing the primary stability of a proximal humerus locking plate because the effect of augmentation can be exploited more effectively limiting it to the degree required. The technique of augmentation is simple and can be applied in open and minimally invasive procedures. When the correct procedure is used, complications (cement leakage into the joint) can be avoided.

  9. A proximity effect in adults' contamination intuitions

    Directory of Open Access Journals (Sweden)

    Laura R. Kim

    2011-04-01

    Full Text Available Magical beliefs about contagion via contact (Rozin, Nemeroff, Wane, and Sherrod, 1989 may emerge when people overgeneralize real-world mechanisms of contamination beyond their appropriate boundaries (Lindeman and Aarnio, 2007. Do people similarly overextend knowledge of airborne contamination mechanisms? Previous work has shown that very young children believe merely being close to a contamination source can contaminate an item (Springer and Belk 1994; we asked whether this same hyper-avoidant intuition is also reflected in adults' judgments. In two studies, we measured adults' ratings of the desirability of an object that had made contact with a source of contamination, an object nearby that had made no contact with the contaminant, and an object far away that had also made no contact. Adults showed a clear proximity effect, wherein objects near the contamination source were perceived to be less desirable than those far away, even though a separate group of adults unanimously acknowledged that contaminants could not possibly have made contact with either the nearby or far-away object (Study 1. The proximity effect also remained robust when a third group of adults was explicitly told that no contaminating particles had made contact with the objects at any time (Study 2. We discuss implications of our findings for extending the scope of magical contagion effects beyond the contact principle, for understanding the persistence of intuitive theories despite broad acceptance of science-based theories, and for constraining interpretations of the developmental work on proximity beliefs.

  10. Experience on impregnation of wood.en poles with water borne salts

    African Journals Online (AJOL)

    I. Leechability. Since the process depends on osmosis, the preservative must be highly soluble in water and rains may wash it away. 2. Diminished Mechanical Strength. Pricking of the pole at and around the ground line will diminish the mechanical strength of the pole. 3. Cost. Most important of all, the cost of the preserva-.

  11. The effect of poling conditions on the performance of piezoelectric energy harvesters fabricated by wet chemistry

    KAUST Repository

    Fuentes-Fernandez, Erika Maria-Anai; Gnade, Bruce E; Quevedo-Ló pez, Manuel Angel; Shah, Pradeep; Alshareef, Husam N.

    2015-01-01

    The effect of poling conditions on the power output of piezoelectric energy harvesters using sol-gel based Pb(Zr0.53,Ti0.47)O3-Pb(Zn1/3,Nb2/3)O3 piezoelectric thin-films has been investigated. A strong correlation was established between the poling

  12. Development of a field pole of 1 MW-class HTS motor

    International Nuclear Information System (INIS)

    Yuan, S; Kimura, Y; Miki, M; Felder, B; Tsuzuki, K; Izumi, M; Ida, T; Umemoto, K; Aizawa, K; Yokoyama, M

    2010-01-01

    We report a field-pole high-temperature superconductor (HTS) magnet designed for 1 MW-class motor for propulsion. The field pole is assembled to the rotor of the radial-type motor. Each field pole is composed of HTS-Bi2223 tape wound into coils which have been piled up as a double pancake coils. In the design concept of the motor, we employ field poles without iron core. We prepared the test field-pole coil, whose dimension is smaller than the designed one for 1 MW, and tested its performances after cooling under self-field and external magnetic field. We verified the operation with the minimum bend radius of the coils required in the motor design, while keeping an optimal current which is lower than the critical current of the field-pole coil. The test HTS field poles were successfully cooled down and operated under a magnetic field ranging up to 5 T. We report the results of the test field-pole coil and the manufacture of a practical racetrack coil with Bi2223 and discuss the adaptability to 1 MW-class motors.

  13. Risk Management in the Original Extreme Sporting Event: The Pole Vault

    Science.gov (United States)

    Bemiller, Jim; Hardin, Robin

    2010-01-01

    The pole vault was considered the ultimate test of physical ability and daring before the advent of modern extreme sports such as skateboarding, snowboarding, and mountain biking. The inherent risks of the pole vault have been well documented. The National Center for Catastrophic Sport Injury Research reported in 2007 that the catastrophic injury…

  14. Renormalization Group Invariance of the Pole Mass in the Multi-Higgs System

    Science.gov (United States)

    Kim, Chungku

    2018-06-01

    We have investigated the renormalization group running of the pole mass in the multi-Higgs theory in two different types of gauge fixing conditions. The pole mass, when expressed in terms of the Lagrangian parameters, turns out to be invariant under the renormalization group with the beta and gamma functions of the symmetric phase.

  15. Converting point-wise nuclear cross sections to pole representation using regularized vector fitting

    Science.gov (United States)

    Peng, Xingjie; Ducru, Pablo; Liu, Shichang; Forget, Benoit; Liang, Jingang; Smith, Kord

    2018-03-01

    Direct Doppler broadening of nuclear cross sections in Monte Carlo codes has been widely sought for coupled reactor simulations. One recent approach proposed analytical broadening using a pole representation of the commonly used resonance models and the introduction of a local windowing scheme to improve performance (Hwang, 1987; Forget et al., 2014; Josey et al., 2015, 2016). This pole representation has been achieved in the past by converting resonance parameters in the evaluation nuclear data library into poles and residues. However, cross sections of some isotopes are only provided as point-wise data in ENDF/B-VII.1 library. To convert these isotopes to pole representation, a recent approach has been proposed using the relaxed vector fitting (RVF) algorithm (Gustavsen and Semlyen, 1999; Gustavsen, 2006; Liu et al., 2018). This approach however needs to specify ahead of time the number of poles. This article addresses this issue by adding a poles and residues filtering step to the RVF procedure. This regularized VF (ReV-Fit) algorithm is shown to efficiently converge the poles close to the physical ones, eliminating most of the superfluous poles, and thus enabling the conversion of point-wise nuclear cross sections.

  16. Crown Release Increases Diameter Growth and Bole Sprouting of Pole-Size Yellow Birch

    Science.gov (United States)

    Gayne G. Erdmann; Ralph M. Jr. Peterson

    1971-01-01

    During the second and third years after release, dominant, codominant, and intermediate pole-size yellow birch grew nearly twice as fast in diameter as unreleased poles. Growth rates were also related to foliage density. Epicormic sprouting was increased by crown release but most sprouting occured in the second log.

  17. Threshold for strong thermal dephasing in periodically poled KTP in external cavity frequency doubling

    DEFF Research Database (Denmark)

    Lundeman, Jesper Holm; Jensen, Ole Bjarlin; Andersen, Peter E.

    2009-01-01

    We present a measurement series of the efficiency of periodically poled KTP used for second-harmonic generation in an external phase-locked cavity. Due to the high absorption (0.01 cm^−1) in the PPKTP crystal at the pump wavelength a strong thermal dephasing of the periodically poled grating...

  18. Development of a field pole of 1 MW-class HTS motor

    Science.gov (United States)

    Yuan, S.; Kimura, Y.; Miki, M.; Felder, B.; Tsuzuki, K.; Ida, T.; Izumi, M.; Umemoto, K.; Aizawa, K.; Yokoyama, M.

    2010-06-01

    We report a field-pole high-temperature superconductor (HTS) magnet designed for 1 MW-class motor for propulsion. The field pole is assembled to the rotor of the radial-type motor. Each field pole is composed of HTS-Bi2223 tape wound into coils which have been piled up as a double pancake coils. In the design concept of the motor, we employ field poles without iron core. We prepared the test field-pole coil, whose dimension is smaller than the designed one for 1 MW, and tested its performances after cooling under self-field and external magnetic field. We verified the operation with the minimum bend radius of the coils required in the motor design, while keeping an optimal current which is lower than the critical current of the field-pole coil. The test HTS field poles were successfully cooled down and operated under a magnetic field ranging up to 5 T. We report the results of the test field-pole coil and the manufacture of a practical racetrack coil with Bi2223 and discuss the adaptability to 1 MW-class motors.

  19. Institutional Evaluation in Poles of the Open University System of Brazil

    Directory of Open Access Journals (Sweden)

    Alexciano de Sousa Martins

    2018-03-01

    Full Text Available The study wanted to know the institutional evaluation in poles of distance education, of the Open University of Brazil (UAB system, analyzing the poles of the State of Ceará. The UAB system of the Brazilian Ministry of Education makes it possible to offer courses of higher level agreements with public universities. Ceará counts on UAB poles, since 2006, that form teachers and other professionals, even in regions lacking public higher education. The objective of this study was to discuss the importance of the institutional evaluation in the poles of the Open University of Brazil program through an exploratory and descriptive field research, showing that the institutional evaluation at the poles is minimal and out of line with the legislation in force. Suggestions on how to develop the evaluative practice.

  20. Glass fiber -reinforced plastic tapered poles for transmission and distribution lines: development and experimental study

    International Nuclear Information System (INIS)

    Ibrahim, S.; Burachysnsky, V.; Polyzois, D.

    1999-01-01

    A research project to develop lightweight poles for use in power transmission and distribution lines and involving the use of glass fiber-reinforced plastic using the filament winding process is described. Twelve full scale specimen poles were designed, fabricated and subjected to cantilever bending to test failure modes. The test parameters included fiber orientation, ratio of longitudinal-to-circumferential fiber, and the number of layers. Results showed that local buckling was the most dominant failure mode, attributable to the high radius-to-thickness ratio of the specimen poles. Overall, however, these fiber-reinforced plastic poles compared favourably to wooden poles in carrying capacity with significant weight reduction. Lateral displacement at ultimate loads did not exceed the acceptable limit of 10 per cent of the specimen free length. 7 refs., 3 tabs., 2 figs

  1. Optimizing detection of road furniture (pole-like object in Mobile Laser Scanner data

    Directory of Open Access Journals (Sweden)

    D. Li

    2013-10-01

    Full Text Available Due to the road safety problem is becoming more and more serious recent years, existing road safety assessment by using automatic method is necessary. Meanwhile, since the pole-like objects have large effect on road safety and are in high demand as facilities to be managed, the automatic pole-like objects extraction is becoming a hot issue. As a result, a robust, quick and automatic pole-like object detection algorithm in MLS data is proposed in this paper. Two datasets are tested to show performance of the proposed algorithm, it demonstrates that it is feasible to detect tree with an overall accuracy of over 92% and other pole-like object of 72% in dataset A and 82% of tree points and 75% of other pole points in dataset B.

  2. Non-uniformly sampled grids in double pole coordinate system for freeform reflector construction

    Science.gov (United States)

    Ma, Donglin; Pacheco, Shaun; Feng, Zexin; Liang, Rongguang

    2015-08-01

    We propose a new method to design freeform reflectors by nonuniformly sampling the source intensity distribution in double pole coordinate system. In double pole coordinate system, there is no pole for the whole hemisphere because both poles of the spherical coordinate system are moved to southernmost point of the sphere and overlapped together. With symmetric definition of both angular coordinates in the modified double pole coordinate system, a better match between the source intensity distribution and target irradiance distribution can be achieved for reflectors with large acceptance solid angle, leading to higher light efficiency and better uniformity on the target surface. With non-uniform sampling of the source intensity, we can design circular freeform reflector to obtain uniform rectangular illumination pattern. Aided by the feedback optimization, the freeform reflector can achieve the collection efficiency for ideal point source over 0.7 and relative standard deviation (RSD) less than 0.1.

  3. FEM Analysis of Brushless DC Servomotor with Fractional Number of Slots per Pole

    Directory of Open Access Journals (Sweden)

    BALUTA, G.

    2014-02-01

    Full Text Available The authors present in this paper the analysis with Finite Element Method (FEM of the magnetic circuit for a Brushless DC servomotor with fractional number of slots/pole (9 slots and 10 poles. For this purpose, FEMM 4.2 software package was used for the analysis. To obtain the waveforms of Back-ElectroMotive Forces (BEMFs, electromagnetic and cogging torque for servomotor a program in LUA scripting language (integrated into interactive shell of FEMM4.2 has been created. A comparation with a structure with integer number of slots/pole (18 slots and 6 poles was also realized. The analysis results prove that the structure chosen is an optimal solution: sinusoidal waveforms of BEMFs, improved electromagnetic torque and reduced cogging torque. Therefore, the operating characteristics of the servomotor with 9/10 slots/poles manufactured by Sistem Euroteh Company and included in an integrated electrical drives system are presented in this paper.

  4. A Regularized Algorithm for the Proximal Split Feasibility Problem

    Directory of Open Access Journals (Sweden)

    Zhangsong Yao

    2014-01-01

    Full Text Available The proximal split feasibility problem has been studied. A regularized method has been presented for solving the proximal split feasibility problem. Strong convergence theorem is given.

  5. Treatment of proximal ulna and olecranon fractures by dorsal plating

    NARCIS (Netherlands)

    Kloen, Peter; Buijze, Geert A.

    2009-01-01

    OBJECTIVE : Anatomic reconstruction of proximal ulna and olecranon fractures allowing early mobilization and prevention of ulnohumeral arthritis. INDICATIONS : Comminuted olecranon or proximal ulna fractures (including Monteggia fractures), olecranon fractures extending distally from the coronoid

  6. Reliability assessment of power pole infrastructure incorporating deterioration and network maintenance

    International Nuclear Information System (INIS)

    Ryan, Paraic C.; Stewart, Mark G.; Spencer, Nathan; Li, Yue

    2014-01-01

    There is considerable investment in timber utility poles worldwide, and there is a need to examine the structural reliability and probability based management optimisation of these power distribution infrastructure elements. The work presented in this paper builds on the existing studies in this area through assessment of both treated and untreated timber power poles, with the effects of deterioration and network maintenance incorporated in the analysis. This more realistic assessment approach, with deterioration and maintenance considered, was achieved using event-based Monte Carlo simulation. The output from the probabilistic model is used to illustrate the importance of considering network maintenance in the time-dependent structural reliability assessment of timber power poles. Under wind load, treated and untreated poles designed and maintained in accordance with existing Australian standards were found to have similar failure rates. However, untreated pole networks required approximately twice as many maintenance based pole replacements to sustain the same level of reliability. The effect of four different network maintenance strategies on infrastructure performance was also investigated herein. This assessment highlighted the fact that slight alterations to network maintenance practices can lead to significant changes in performance of timber power pole networks. - Highlights: • A time-dependent structural reliability model was developed for timber power poles. • Deterioration and network maintenance were incorporated into this event based model. • Network maintenance had a significant impact on power pole wind vulnerability. • Treated and untreated poles designed to Australian standards had similar reliability. • Minor alterations to maintenance strategies had large effects on network performance

  7. Ulysses(*) reaches the South Pole of the Sun

    Science.gov (United States)

    1994-08-01

    One of the many investigations being carried out is a search for the Sun's south magnetic pole. As in the case of the Earth, the magnetic pole is offset from the rotation axis, and at some time in September it should sweep directly into line with Ulysses. Just as the polar regions of the Earth were the last to be explored, so it is with the Sun. For more than thirty years spacecraft have investigated the stream of electric particles know as the solar wind. Ulysses, developed by ESA, built by European Industry and flown in collaboration with NASA, is the first to fly through the solar wind coming from the poles. As Ulysses reaches its highest solar latitude of 80.2 degrees on 13 September, European and American researchers will gather at the ESA/ESTEC, the European Space Research and Technology Centre in Noordwijk, the Netherlands, for a scientific workshop at which they will assess the results from the nine experiments carried by the spacecraft. For the week of the workshop, the ESA/ESTEC conference centre will be transformed into a busy scientific laboratory. The large meeting rooms will be divided into 24 working areas, where the Ulysses experiment teams will take up temporary residence. Bringing a variety of computing equipment with them, the scientists will be able to retrieve the latest data from the spacecraft and perform detailed analyses. The emphasis will be on informality, with exchange of scientific ideas - and data - the key ingredient, leading ultimately to a better understanding of the fascinating information being gathered by Ulysses on its unique exploratory journey. Presentations to the media at ESA/ESTEC will start at 10h00 on 16 September. Media representatives wishing to attend are kindly requested to fill out the attached form and return it - preferably by fax (+33.1.42.73.76.90) - to : ESA Public Relations Division, 8/10, rue Mario Nikis - 75015-PARIS. Note to Television Editors : A video index, containing extensive background material on the

  8. Strong Proximities on Smooth Manifolds and Vorono\\" i Diagrams

    OpenAIRE

    Peters, J. F.; Guadagni, C.

    2015-01-01

    This article introduces strongly near smooth manifolds. The main results are (i) second countability of the strongly hit and far-miss topology on a family $\\mathcal{B}$ of subsets on the Lodato proximity space of regular open sets to which singletons are added, (ii) manifold strong proximity, (iii) strong proximity of charts in manifold atlases implies that the charts have nonempty intersection. The application of these results is given in terms of the nearness of atlases and charts of proxim...

  9. Strategi Pengembangan Daerah Growth Pole melalui Pemanfaatan Potensi Lokal

    Directory of Open Access Journals (Sweden)

    Rusdarti Rusdarti

    2016-12-01

    Full Text Available This research aims to determine the leading sectors that could be developed in each district in Cilacap Regency as a growth pole area. We use location quotient, shift share, and klassen typology as analysis methods. The research results show that not all of the district at Cilacap regency have a leading sector. Further, districts that have leading sectors are as follows. Wanareja only has a leading sector, i.e. agriculture. Secondly, Kawunganten has two leading sectors, agriculture and finance, rent, and company services. Thirdly, Agriculture becomes the only leading sector of Kampung Laut District. Fourthly, Mining and extraction are the leading sectors of Kesugihan District. Fifthly, Sampang District has buildings and finance sectors as the leading sectors. Sixthly, Kroya District leads in trade, hotel, and restaurant sectors. Seventhly, South Cilacap District leads in mining and extraction sectors. Eighthly, Central Cilacap District has manufacturing, electricity, gas and clean water, building and services as leading sectors. Lastly, North Cilacap District has electricity, gas and clean water, manufacturing, building and services as leading sectors. Abstrak   Tujuan dari penelitian ini adalah menentukan sektor unggulan yang dapat dikembangkan di tiap kecamatan di Kabupaten Cilacap sebagai salah satu daerah growth pole. Alat analisis yang digunakan dalam penelitian ini yaitu location quotient, shift share dan klassen typologi. Hasil penelitian menunjukkan tidak semua kecamatan di kabupaten Cilacap memiliki sektor unggulan. Beberapa daerah yang memiliki sektor unggulan diantaranya adalah  Kecamatan Wanareja hanya memiliki satu sektor unggulan yaitu pertanian. Kedua adalah Kecamatan Kawunganten memiliki dua sektor unggulan yaitu sektor pertanian dan sektor keuangan, persewaan dan jasa perusahaan. Kecamatan Kampung Laut, dimana sektor pertanian pada kecamatan ini sangatlah unggul. Kecamatan kesugihan juga memiliki satu sektor unggulan yaitu

  10. Linking Atmospheric Pollution to Cryospheric Changes over the Third Pole

    Science.gov (United States)

    Kang, S.; Zhang, Q.; Ji, Z.; Li, Y.; Chen, J.; Zhang, G.; Li, C.; Cong, Z.; Chen, P.; Guo, J.; Huang, J.; Tripathee, L.; Rupakheti, D.; Li, X.; Zhang, Y.; Panday, A. K.; Rupakheti, M.

    2016-12-01

    Known as "the Third Pole" (TP), the Tibetan Plateau and surrounding mountains hold the largest aggregate of glaciers outside the pole regions. Recent monitoring and projection indicated an accelerated glacier decline and increasing glacier runoff. The long-range transport of South Asian atmospheric pollutants, including light absorbing impurities (LAIs) such as black carbon (BC) and mineral dust (MD), can absorb the solar radiation in the atmosphere and reduce albedo after being deposited onto the cryosphere, thereby promoting glacier and snow melt. A coordinated atmospheric pollution monitoring network has been launched covering the TP with emphasis on trans-Himalayan transects since 2013. TSP were collected for 24h at an interval of 3-6 days. BC/OC, polycyclic aromatic hydrocarbons (PAHs) and heavy metals were measured. Results reveal a consistent decrease in almost all analyzed parameters from south to north across the Himalayas. Geochemical signatures of carbonaceous aerosols indicate dominant sources of biomass burning and vehicle exhaust, in line with results of PAHs. Integrated analysis of satellite images and air mass trajectories suggest that the trans-boundary air pollution occurred episodically and concentrated in pre-monsoon seasons via upper air circulation, through-valley wind, and local convection. Simulation results showed that carbonaceous aerosols produced positive/negative shortwave radiative forcing in the atmosphere/ground surface. Aerosols increased surface air temperatures by 0.1-0.5° over the TP and decreased temperatures in South Asia during the monsoon season. Surface snow/ice samples were collected from benchmark glaciers to estimate the impacts of LAIs on glacier melt with model assistance. BC (37%) and MD (32%) contribute to the summer melting of Laohugou Glacier in the northern TP. MD (38%) contributed more glacier melt than BC (11%) on Zhadang Glacier in the southern TP. In the southeastern TP, BC and MD contribute to 30% of the

  11. Searching for Terrain Softening near Mercury's North Pole

    Science.gov (United States)

    Cobian, P. S.; Vilas, F.; Lederer, S. M.; Barlow, N. G.

    2004-01-01

    In 1999, following the initial discovery of radar bright craters near both poles of Mercury measured the depth-todiameter (d/D) ratios of 170 impact craters in Mariner 10 images covering four different regions on Mercury s surface. Rapid softening of crater structure, indicated by lower d/D ratios, could indicate the possibility of subsurface water ice in Mercury's terrain originating from an internal source in the planet. Their study included 3 specific radar bright craters suggested to contain ice. They concluded that no terrain softening was apparent, and a rapidly emplaced exogenic water source was the most likely source for the proposed ice in these craters. Recent radar observations of the Mercurian North pole have pinpointed many additional radar bright areas with a resolution 10x better than previous radar measurements, and which correlate with craters imaged by Mariner 10. These craters are correlated with regions that are permanently shaded from direct sunlight, and are consistent with observations of clean water ice. We have expanded the initial study by Barlow et al. to include d/D measurements of 12 craters newly identified as radar bright at latitudes poleward of +80o. The radar reflectivity resemblances to Mars south polar cap and echoes from three icy Galilean satellites suggest that these craters too may have polar ice on Mercury. The effect of subsurface H20 on impact craters is a decrease in its d/D ratio, and softening of crater rims over a period of time. The study of Barlow et al., focused on determining the d/D ratios of 170 impact craters in the Borealis (north polar), Tolstoj (equatorial), Kuiper (equatorial), and Bach (south polar) quadrangles. This work focuses on the newly discovered radar bright craters, investigating their d/D ratios as an expansion of the earlier work..We compare our results to the statistical results from Barlow et al. here. With the upcoming Messenger spacecraft mission to Mercury, this is an especially timely study

  12. Critical Proximity as a Methodological Move in Techno-Anthropology

    DEFF Research Database (Denmark)

    Birkbak, Andreas; Petersen, Morten Krogh; Elgaard Jensen, Torben

    2015-01-01

    proximity.’ Critical proximity offers an alternative to critical distance, especially with respect to avoiding premature references to abstract panoramas such as democratization and capitalist exploitation in the quest to conduct ‘critical’ analysis. Critical proximity implies, instead, granting the beings...

  13. 75 FR 5009 - Proximity Detection Systems for Underground Mines

    Science.gov (United States)

    2010-02-01

    ... Proximity Detection Systems for Underground Mines AGENCY: Mine Safety and Health Administration, Labor... information regarding whether the use of proximity detection systems would reduce the risk of accidents where... . Information on MSHA-approved proximity detection systems is available on the Internet at http://www.msha.gov...

  14. India plans to land near moon's south pole

    Science.gov (United States)

    Bagla, Pallava

    2018-02-01

    Sometime this summer, an Indian spacecraft orbiting over the moon's far side will release a lander. The craft will ease to a soft landing just after lunar sunrise on an ancient, table-flat plain about 600 kilometers from the south pole. There, it will unleash a rover into territory never before explored at the surface. That's the ambitious vision for India's second voyage to the moon in a decade, due to launch in the coming weeks. If Chandrayaan-2 is successful, it will pave the way for even more ambitious Indian missions, such as landings on Mars and an asteroid, as well as a Venus probe. Lunar scientists have much at stake, too. Chandrayaan-2 will collect data on the moon's thin envelope of plasma, as well as isotopes such as helium-3, a potential fuel for future fusion energy reactors. And it will follow up on a stunning discovery by India's first lunar foray, which found water molecules on the moon in 2009.

  15. Proximal sensing for soil carbon accounting

    Science.gov (United States)

    England, Jacqueline R.; Viscarra Rossel, Raphael A.

    2018-05-01

    Maintaining or increasing soil organic carbon (C) is vital for securing food production and for mitigating greenhouse gas (GHG) emissions, climate change, and land degradation. Some land management practices in cropping, grazing, horticultural, and mixed farming systems can be used to increase organic C in soil, but to assess their effectiveness, we need accurate and cost-efficient methods for measuring and monitoring the change. To determine the stock of organic C in soil, one requires measurements of soil organic C concentration, bulk density, and gravel content, but using conventional laboratory-based analytical methods is expensive. Our aim here is to review the current state of proximal sensing for the development of new soil C accounting methods for emissions reporting and in emissions reduction schemes. We evaluated sensing techniques in terms of their rapidity, cost, accuracy, safety, readiness, and their state of development. The most suitable method for measuring soil organic C concentrations appears to be visible-near-infrared (vis-NIR) spectroscopy and, for bulk density, active gamma-ray attenuation. Sensors for measuring gravel have not been developed, but an interim solution with rapid wet sieving and automated measurement appears useful. Field-deployable, multi-sensor systems are needed for cost-efficient soil C accounting. Proximal sensing can be used for soil organic C accounting, but the methods need to be standardized and procedural guidelines need to be developed to ensure proficient measurement and accurate reporting and verification. These are particularly important if the schemes use financial incentives for landholders to adopt management practices to sequester soil organic C. We list and discuss requirements for developing new soil C accounting methods based on proximal sensing, including requirements for recording, verification, and auditing.

  16. Keldysh proximity action for disordered superconductors

    International Nuclear Information System (INIS)

    Feigel'man, M.V.; Larkin, A.I.; Skvortsov, M.A.

    2005-01-01

    We review a novel approach to the superconductive proximity effect in disordered normal-superconducting (N-S) structures. The method is based on the multicharge Keldysh action and is suitable for the treatment of interaction and fluctuation effects. As an application of the formalism, we study the subgap conductance and noise in two-dimensional N-S system in the presence of the electron-electron interaction in the Cooper channel. It is shown that singular nature of the interaction correction at large scales leads to a nonmonotonous temperature, voltage and magnetic field dependence of the Andreev conductance. (author)

  17. Phonon structure in proximity tunnel junctions

    International Nuclear Information System (INIS)

    Zarate, H.G.; Carbotte, J.P.

    1985-01-01

    We have iterated to convergence, for the first time, a set of four coupled real axis Eliashberg equations for the superconducting gap and renormalization functions on each side of a proximity sandwich. We find that the phenomenological procedures developed to extract the size of the normal side electron-phonon interaction from tunneling data are often reasonable but may in some cases need modifications. In all the cases considered the superconducting phonon structure reflected on the normal side, as well as other structures, shows considerable agreement with experiment as to size, shape, and variation with barrier transmission coefficient. Finally, we study the effects of depairing on these structures

  18. Proximal iliotibial band syndrome: case report

    Directory of Open Access Journals (Sweden)

    Guilherme Guadagnini Falotico

    2013-08-01

    Full Text Available OBJECTIVE: The overuse injuries in the hip joint occur commonly in sports practitioners and currently due to technical advances in diagnostic imaging, especially magnetic resonance imaging (MRI, are often misdiagnosed. Recently, a group of people were reported, all female, with pain and swelling in the pelvic region.T2-weighted MRI showed increased signal in the enthesis of the iliotibial band (ITB along the lower border of the iliac tubercle. We report a case of a 34 year old woman, non-professional runner, with pain at the iliac crest with no history of trauma and whose MRI was compatible with the proximal iliotibial band syndrome.

  19. Noise measurements on proximity effect bridges

    International Nuclear Information System (INIS)

    Decker, S.K.; Mercereau, J.E.

    1975-01-01

    Audio frequency noise density measurements were performed on weakly superconducting proximity effect bridges on using a cooled transformer and room temperature low noise preamplifier. The noise temperature of the measuring system is approximately 4 0 K for a 0.9 Ω resistor. Noise density was measured as a function of bias current and temperature for the bridges. Excess noise above that expected from Johnson noise for a resistor equal to the dynamic resistance of the bridges was observed in the region near the critical current of the device. At high currents compared to the critical current, the noise density closely approaches that given by Johnson noise

  20. Self-Poling of BiFeO3 Thick Films.

    Science.gov (United States)

    Khomyakova, Evgeniya; Sadl, Matej; Ursic, Hana; Daniels, John; Malic, Barbara; Bencan, Andreja; Damjanovic, Dragan; Rojac, Tadej

    2016-08-03

    Bismuth ferrite (BiFeO3) is difficult to pole because of the combination of its high coercive field and high electrical conductivity. This problem is particularly pronounced in thick films. The poling, however, must be performed to achieve a large macroscopic piezoelectric response. This study presents evidence of a prominent and reproducible self-poling effect in few-tens-of-micrometer-thick BiFeO3 films. Direct and converse piezoelectric measurements confirmed that the as-sintered BiFeO3 thick films yield d33 values of up to ∼20 pC/N. It was observed that a significant self-poling effect only appears in cases when the films are heated and cooled through the ferroelectric-paraelectric phase transition (Curie temperature TC ∼ 820 °C). These self-poled films exhibit a microstructure with randomly oriented columnar grains. The presence of a compressive strain gradient across the film thickness cooled from above the TC was experimentally confirmed and is suggested to be responsible for the self-poling effect. Finally, the macroscopic d33 response of the self-poled BiFeO3 film was characterized as a function of the driving-field frequency and amplitude.