WorldWideScience

Sample records for provisional prosthetic materials

  1. Bacterial adhesion of porphyromonas gingivalis on provisional fixed prosthetic materials

    Directory of Open Access Journals (Sweden)

    Mustafa Zortuk

    2010-01-01

    Conclusion : The quantity of bacterial adhesion and surface roughness differed among the assessed provisional fixed prosthodontic materials. The light-polymerized provisional material Revotek LC had rougher surface and more bacterial adhesion compared with the others.

  2. Analysis of colour stability of selected provisional prosthetic materials: an in vitro study.

    Science.gov (United States)

    Koczorowski, Ryszard; Linkowska-Swidzińska, Kamila; Gedrange, Tomasz; Swidziński, Teodor

    2009-08-01

    Prosthetic restorative materials (that are) used for temporary fixed dentures tend to exhibit variable discolouration over several weeks of use. The aim of this study was to perform a spectrophotometric analysis of the influence of selected discolouring factors on the colour stability of provisional prosthetic materials in vitro. In the study, the following prosthetic materials for short-term use in the oral cavity were evaluated: Luxatemp, Structur 2S.C., Protemp II, Zhermacryl STC and Dentalon Plus. Samples of these materials were immersed in coffee, tea and dark fruit juice for 60 h at different pH values. Colour was evaluated by determining the monochromatic coefficients of light reflected by the samples, using a spectrophotometric method. Results received in artificial light (illuminant A) were compared with those obtained in daylight (illuminant D65). Changes in colour and its parameters according to the CIE L*a*b* system were analysed. The analysis (of the colour and colour parameters) of the tested materials in two types of light showed that Structur displayed the greatest tendency to discolouration and that the least tendency to discolouration was exhibited by Dentalon Plus. The fact that colour parameters obtained in two types of light were not identical suggests that changes in the colour of the same material may be perceived differently, depending on the illuminant. Provisional prosthetic materials show variable colour stability under different conditions in the oral cavity. The colour of prosthetic materials may be perceived differently, depending on the illuminant and the effect of the environment in which they are used.

  3. Bacterial leakage of provisional restorative materials used in endodontics.

    Science.gov (United States)

    Hartwell, Gary R; Loucks, Carina A; Reavley, Brenton A

    2010-04-01

    To test the bacterial sealing ability of commonly used provisional endodontic restorative materials. This study investigated Cavit (3M ESPE), Ketac (3M ESPE), DuoTemp (Coltane/Whaledent), and a combination technique using Ketac and Cavit. One hundred molars were randomly selected and then mounted in an apparatus that isolated the crown portion of the tooth. Provisional restorative materials were placed in an open access following manufacturer guidelines. Streptococcus mutans was applied to the samples, and results were tabulated over the course of 4 weeks. Cavit and DuoTemp performed the best, and Ketac performed the worst. After 14 days, however, all materials leaked in over half of the samples. No material can be recommended as superior in providing a reliable seal after 14 days.

  4. In vitro color stability of provisional restorative materials

    Directory of Open Access Journals (Sweden)

    Hamid Jalali

    2012-01-01

    Aims: The purpose of this study was to investigate the effect of tea on provisional restorative materials. Setting and Design: This study was designed to measure the degree of color change of three acrylic resin provisional materials, before and after immersion in artificial saliva and artificial saliva-tea solution for 2 and 4 weeks. Materials and Methods : Three types of acrylic provisional materials (duralay, tempron, acropars TRP, were studied. Twenty disks (20±0.1 mm by 2±0.05 mm were fabricated from each material. Specimens were polished with acrylic bur using pumice and diamond polishing paste. Base line color was measured using a spectrophotometer. Ten disks were stored in artificial saliva and 10 were stored in a solution of artificial saliva and tea at room temperature. Color measurements were made after 2 and 4 weeks of immersion. Statistical analysis used: Differences in color changes were compared by two way ANOVA, across the six groups, followed by a Turkey-Kramer′s multiple comparison test. Results: For specimens immersed in artificial saliva, the color change of methyl methacrylate materials; duralay (ΔE=4.94 and tempron (ΔE=6.54, was significantly more than butyl methacrylate material; acropars (ΔE=4.10. After immersion in an artificial saliva- tea solution, tempron exhibited less color change (ΔE=8.50 compared to duralay (ΔE=10.93 and acropars (ΔE=15.64. Conclusion: Color stability of methyl methacrylate is higher than butyl methacrylates so if provisional materials are used for extended periods of time; tempron is preferred.

  5. Pre-prosthetic minor tooth movement with elastic separating ring & provisional restoration modification: case report

    Directory of Open Access Journals (Sweden)

    Haneol Shin

    2012-05-01

    Full Text Available Proximal caries or coronal defect in posterior teeth may result in the loss of proximal space and drifting of neighboring teeth, which makes restoration difficult. Inability to restore proper contours and to align tooth axis properly are commonly encountered problems when planning tooth restoration. Moreover, tilted teeth aggravate periodontal tissue breakdown, such as pseudo-pocket, and angular osseous defect. The purpose of this case presentation is to describe a simple technique for inducing minor tooth movement with orthodontic separating ring and provisional restoration modification. This method was used to create crown placement space on mesially tilted molar. This method is easy, simple and efficient technique which could be used in interproximal space gaining in selected situation.

  6. Effect of nightguard vital bleaching gel on the color stability of provisional restorative materials

    OpenAIRE

    Salwa Omar Bajunaid

    2016-01-01

    Purpose: To assess the hypothesis that there was no difference in effect of 10% and 15% tooth bleaching agents on color stability of materials used for provisional fixed dental prosthesis. Methodology: Fifteen samples from two materials used for provisional fixed dental prosthesis: methacrylate-based and composite-based materials and 15 preformed polycarbonate crowns soaked in bleaching gel or distilled water. Spectrophotometer recorded color of specimens at baseline, after 3, 7, and 14 d...

  7. Effect of nightguard vital bleaching gel on the color stability of provisional restorative materials

    Directory of Open Access Journals (Sweden)

    Salwa Omar Bajunaid

    2016-01-01

    Conclusions: Composite-based provisional material showed highest color stability when exposed to vital tooth bleaching gel, whereas methacrylate-based material was the least color stable. Polycarbonate crowns were more color stable when exposed to 15% bleaching gel as opposed to 10% bleaching gel.

  8. Effect of nightguard vital bleaching gel on the color stability of provisional restorative materials.

    Science.gov (United States)

    Bajunaid, Salwa Omar

    2016-01-01

    To assess the hypothesis that there was no difference in effect of 10% and 15% tooth bleaching agents on color stability of materials used for provisional fixed dental prosthesis. Fifteen samples from two materials used for provisional fixed dental prosthesis: methacrylate-based and composite-based materials and 15 preformed polycarbonate crowns soaked in bleaching gel or distilled water. Spectrophotometer recorded color of specimens at baseline, after 3, 7, and 14 days. Data were statistically analyzed using two-factor ANOVA test to compare the color stability of tested materials. Methyl-based provisional material exhibited statistically higher color change when exposed to 10% and 15% bleaching gel (delta EFNx01: 9.0 and 11.1, respectively) as compared to distilled water (delta EFNx01: 2.9). Delta EFNx01 of composite-based material specimens exposed to distilled water was statistically higher (6.3) than specimens exposed to 10% and 15% bleaching gel (1.5 and 1.1, respectively). Polycarbonate crowns showed a statistically lower color change when exposed to 15% (0.9) than to 10% bleaching gel (5.1) or distilled water (5.5). Composite-based provisional material showed highest color stability when exposed to vital tooth bleaching gel, whereas methacrylate-based material was the least color stable. Polycarbonate crowns were more color stable when exposed to 15% bleaching gel as opposed to 10% bleaching gel.

  9. Comparison of the color stability of provisional restorative materials after storing in different drinks

    Directory of Open Access Journals (Sweden)

    Merve Bankoğlu Güngör

    2016-05-01

    Full Text Available OBJECTIVE: The objective of the present study was to compare the color stability of provisional restorative materials after stroring in different drinks. MATERIALS AND METHOD: Thirty specimens (10 mm in diameter and 2 mm in thickness were prepared from three different materials (Temdent, TRIAD ve TelioCAD. Specimens were divided into six groups according to drinks (distilled water, coffee, tea, cola, red wine and fruit juice; n=5. Specimens were stored in these drinks at 37 °C for 48 hours. The L*, a*, b* values of the specimens were measured with a spectrophometer and recorded before and after storing in drinks. Then ΔE* values were calculated. The data were statistically analyzed using two-way analysis of variance (ANOVA and Tukey’s HSD post hoc tests (α=0.05. RESULTS: Difference between the ΔE* values of specimens stored in different drinks was statistically significant (p<0.05. Color change of TelioCAD specimens was smallest in cola drink and greatest in red wine. Color change of Temdent specimens was smallest in fruit juice and greatest in coffee. For TRIAD specimens, greater color change was observed in coffee, red wine, and tea, in descending order. When the results of storing in the same drink were compared, TRIAD showed the greatest values of color change in coffee and red wine in comparison to the other provisional materials (p<0.05. CONCLUSION: Color stability changed according to the type of the provisional material and the drink. When the drinks were evaluated, greater color changes were observed in coffee, and when the materials were evaluated greater color changes were observed in TRIAD.

  10. The effects of an airborne-particle abrasion and silica-coating on the bond strength between grooved titanium alloy temporary cylinders and provisional veneering materials.

    Science.gov (United States)

    Wei, Ann Yu-Chieh; Sharma, Arun B; Watanabe, Larry G; Finzen, Frederick C

    2011-03-01

    Even though mechanical retentive features, such as grooves, are incorporated into the surface of titanium alloy temporary cylinders, a reliable bond to veneering provisional materials is not always achievable for screw-retained provisional implant restorations. There is insufficient information about the effect of tribochemical silica coating on the bond strength between provisional materials and grooved titanium alloy temporary cylinders. The purpose of this study was to evaluate, in vitro, the effect of an airborne-particle abrasion and silica-coating technique on the bond strength between grooved titanium alloy temporary cylinders and provisional veneering bisphenol-A glycidyl methacrylate and polymethyl methacrylate materials. Forty grooved titanium alloy (Ti-6Al-4V) internal connection implant temporary cylinders were used. A disc of veneering material (7.1 × 3.4 mm) was created around the midsection of each cylinder. Forty specimens were divided into 4 groups (n=10): group NoTxPMMA, no surface treatment and polymethyl methacrylate veneering material; group NoTxBisGMA, no surface treatment and BisGMA veneering material; group AbPMMA, airborne-particle abrasion, silica-coating surface treatment (Rocatec), and polymethyl methacrylate; and group AbBisGMA, airborne-particle abrasion, silica-coating surface treatment (Rocatec), and BisGMA. Each specimen was subjected to ultimate shear load testing at the interface of the veneering material and the temporary cylinder in a universal testing machine at a constant crosshead speed of 5 mm/min. Data were analyzed with a 1-way ANOVA (α=.05) followed by post hoc Student-Newman-Keuls test. Each specimen underwent surface observation with a light microscope at ×40 magnification to compare fracture patterns. Airborne-particle abrasion and silica-coating surface treatment significantly lowered the shear bond strength (Pveneering materials. It weakened the provided mechanical retention, especially when it was used with Bis

  11. Development of Standardized Material Testing Protocols for Prosthetic Liners.

    Science.gov (United States)

    Cagle, John C; Reinhall, Per G; Hafner, Brian J; Sanders, Joan E

    2017-04-01

    A set of protocols was created to characterize prosthetic liners across six clinically relevant material properties. Properties included compressive elasticity, shear elasticity, tensile elasticity, volumetric elasticity, coefficient of friction (CoF), and thermal conductivity. Eighteen prosthetic liners representing the diverse range of commercial products were evaluated to create test procedures that maximized repeatability, minimized error, and provided clinically meaningful results. Shear and tensile elasticity test designs were augmented with finite element analysis (FEA) to optimize specimen geometries. Results showed that because of the wide range of available liner products, the compressive elasticity and tensile elasticity tests required two test maxima; samples were tested until they met either a strain-based or a stress-based maximum, whichever was reached first. The shear and tensile elasticity tests required that no cyclic conditioning be conducted because of limited endurance of the mounting adhesive with some liner materials. The coefficient of friction test was based on dynamic coefficient of friction, as it proved to be a more reliable measurement than static coefficient of friction. The volumetric elasticity test required that air be released beneath samples in the test chamber before testing. The thermal conductivity test best reflected the clinical environment when thermal grease was omitted and when liner samples were placed under pressure consistent with load bearing conditions. The developed procedures provide a standardized approach for evaluating liner products in the prosthetics industry. Test results can be used to improve clinical selection of liners for individual patients and guide development of new liner products.

  12. Prosthetic limb sockets from plant-based composite materials.

    Science.gov (United States)

    Campbell, Andrew I; Sexton, Sandra; Schaschke, Carl J; Kinsman, Harry; McLaughlin, Brian; Boyle, Martin

    2012-06-01

    There is a considerable demand for lower limb prostheses globally due to vascular disease, war, conflict, land mines and natural disasters. Conventional composite materials used for prosthetic limb sockets include acrylic resins, glass and carbon fibres, which produce harmful gasses and dust in their manufacture. To investigate the feasibility of using a renewable plant oil-based polycarbonate-polyurethane copolymer resin and plant fibre composite, instead of conventional materials, to improve safety and accessibility of prosthetic limb manufacture. Experimental, bench research. Test pieces of the resin with a range of plant fibres (10.0% by volume) were prepared and tensile strengths were tested. Test sockets of both conventional composite materials and plant resin with plant fibres were constructed and tested to destruction. Combinations of plant resin and either banana or ramie fibres gave high tensile strengths. The conventional composite material socket and plant resin with ramie composite socket failed at a similar loading, exceeding the ISO 10328 standard. Both wall thickness and fibre-matrix adhesion played a significant role in socket strength. From this limited study we conclude that the plant resin and ramie fibre composite socket has the potential to replace the standard layup. Further mechanical and biocompatibility testing as well as a full economic analysis is required. Using readily sourced and renewable natural fibres and a low-volatile bio-resin has potential to reduce harm to those involved in the manufacture of artificial limb sockets, without compromising socket strength and benefitting clinicians working in poorer countries where safety equipment is scarce. Such composite materials will reduce environmental impact.

  13. STUDY OF SURFACE PHENOMENA IN MATERIALS OF PROSTHETIC RESTORATION

    Directory of Open Access Journals (Sweden)

    Mihaela-Păpuşa Vasiliu

    2012-12-01

    Full Text Available As a direct consequence of their application domain – the oral cavity – dental materials are subjected to the corosive action of saliva, being surrounded by microorganisms, fluids and alimentary rests, which modify their surface characteristics. Concerns on the quality of the dental materials explain the numeorus interdisciplinary studies, characterized by a close relation among various scientific domains (physics, chemistry, biology, science of biomaterials, techniques also applied in clinical stomatology. Analysis of the saliva–dental materials interface made use of ceramic surfaces, composites and artificial saliva, permitting to determine the main surface parameters of the materials of prosthetic restoration, calculated with some physical models, starting from measurements of the contact angle: surface energy, its polar and dispersive components, surface rugosity, adhesion mechanic work. All composites showed low values of the adhesion mechanic work, the conclusion being that they are much more hydrophobic than the ceramic materials. Such a property is especially important from an aesthetic perspective, as the hydrophobic materials have a better colour stability in time.

  14. Coronal leakage of provisional restorative materials used in endodontics with and without intracanal medication after exposure to human saliva

    Directory of Open Access Journals (Sweden)

    P Udayakumar

    2016-01-01

    Full Text Available Aim: To determine the coronal leakage of various provisional restorations with and without intracanal medication over time after being exposed to human saliva. Materials and Methods: This study investigated Coltosol F, Cavit, Ketac Molar, and IRM as provisional restorative material. Calcium hydroxide and chlorhexidine were used as an intracanal medicament. Ninety-eight single rooted teeth were randomly selected and then mounted in an apparatus that isolated the crown portion of the tooth. Provisional restorative materials were placed in the access cavity following manufacturer guidelines after placement of intracanal medicament. Human saliva and brain heart infusion broth in 3:1 ratio were applied to the samples, incubated at 37°C, and results were tabulated over the course of 4 weeks by the appearance of turbidity in the lower part of the apparatus. Statistical Analysis: The data were statistically analyzed using proportional Z-test. The level of significance was set at 0.05. Results: Coltosol F and Cavit could significantly prevent the bacterial leakage up to a period of 7 days with a P value of 0.01 and 0.005, respectively. Bacterial recontamination was relatively less in the samples treated with intracanal medicaments up to 14 days. After 14 days, however, all materials leaked in over half of the samples. Conclusion: No provisional restorative material can be considered superior in providing a reliable seal after 14 days. Inter-appointments schedule should not extend beyond 2 weeks and after endodontic therapy final restoration should be completed within 1 week.

  15. An Investigation Into the Integrity of Fit of Provisional Crowns Using Current Proprietary Temporary Crown Materials.

    Science.gov (United States)

    Taylor, Philip D; Georgakis, Georgios; Niggli, Jason

    2016-06-01

    Three methods of direct provisional crown construction were investigated for accuracy of marginal fit. A modified proprietary crown coping was compared to Bis GMA and isobutyl methacrylate resin provisional crowns with margins modified by using a flowable composite and 'bead on' isobutyl methacrylate respectively. Measurement was at 50x magnification at seven sites over the fit surface. Data was analyzed using SPSS version 13.0.1 and measurement compared using the Mann Whitney test set at a significance level of 0.05. Reliability was checked using the Bland Altman test. Statistical significant differences were found between the three groups. The order of best fit was Bis-GMA and flowable composite > isobutyl methacrylate with 'bead on' margins > Bis-GMA modified implant temporary coping. The clinical significance is that the Bis GMA and flowable composite combination can be used with equal confidence to traditional methods of temporarisation.

  16. A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: An in vitrostudy

    Directory of Open Access Journals (Sweden)

    Bhavya Mohandas Amin

    2015-01-01

    Full Text Available Purpose: The purpose of this in vitro study was to evaluate and compare the primary marginal accuracy of four commercially available provisional materials (Protemp 4, Luxatemp Star, Visalys Temp and DPI tooth moulding powder and liquid at 2 time intervals (10 and 30 min. Materials and Methods: A customized stainless steel master model containing two interchangeable dies was used for fabrication of provisional crowns. Forty crowns (n = 10 were fabricated, and each crown was evaluated under a stereomicroscope. Vertical marginal discrepancies were noted and compared at 10 min since the start of mixing and then at 30 min. Observations and Results: Protemp 4 showed the least vertical marginal discrepancy (71.59 μ, followed by Luxatemp Star (91.93 μ at 10 min. DPI showed a marginal discrepancy of 95.94 μ while Visalys Temp crowns had vertical marginal discrepancy of 106.81 μ. There was a significant difference in the marginal discrepancy values of Protemp 4 and Visalys Temp. At 30 min, there was a significant difference between the marginal discrepancy of Protemp 4 crowns (83.11 μ and Visalys Temp crowns (128.97 μ and between Protemp 4 and DPI (118.88 μ. No significant differences were observed between Protemp 4 and Luxatemp Star. Conclusion: The vertical marginal discrepancy of temporary crowns fabricated from the four commercially available provisional materials ranged from 71 to 106 μ immediately after fabrication (at 10 min from the start of mix to 83-128 μ (30 min from the start of mix. The time elapsed after mixing had a significant influence on the marginal accuracy of the crowns.

  17. A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: An in vitro study

    Science.gov (United States)

    Amin, Bhavya Mohandas; Aras, Meena Ajay; Chitre, Vidya

    2015-01-01

    Purpose: The purpose of this in vitro study was to evaluate and compare the primary marginal accuracy of four commercially available provisional materials (Protemp 4, Luxatemp Star, Visalys Temp and DPI tooth moulding powder and liquid) at 2 time intervals (10 and 30 min). Materials and Methods: A customized stainless steel master model containing two interchangeable dies was used for fabrication of provisional crowns. Forty crowns (n = 10) were fabricated, and each crown was evaluated under a stereomicroscope. Vertical marginal discrepancies were noted and compared at 10 min since the start of mixing and then at 30 min. Observations and Results: Protemp 4 showed the least vertical marginal discrepancy (71.59 μ), followed by Luxatemp Star (91.93 μ) at 10 min. DPI showed a marginal discrepancy of 95.94 μ while Visalys Temp crowns had vertical marginal discrepancy of 106.81 μ. There was a significant difference in the marginal discrepancy values of Protemp 4 and Visalys Temp. At 30 min, there was a significant difference between the marginal discrepancy of Protemp 4 crowns (83.11 μ) and Visalys Temp crowns (128.97 μ) and between Protemp 4 and DPI (118.88 μ). No significant differences were observed between Protemp 4 and Luxatemp Star. Conclusion: The vertical marginal discrepancy of temporary crowns fabricated from the four commercially available provisional materials ranged from 71 to 106 μ immediately after fabrication (at 10 min from the start of mix) to 83–128 μ (30 min from the start of mix). The time elapsed after mixing had a significant influence on the marginal accuracy of the crowns. PMID:26097348

  18. The effect of placement of glass fibers and aramid fibers on the fracture resistance of provisional restorative materials.

    Science.gov (United States)

    Saygili, Gülbin; Sahmali, Sevil M; Demirel, Figen

    2003-01-01

    The fracture resistance of provisional restorations is an important concern for the restorative dentist. The fracture resistance of a material is directly related to its transverse strength. Six specimens of similar dimensions were prepared from three resins (PMMA, PEMA and BIS acryl-composite). The resins were reinforced with glass and aramid fibers. The samples were tested immediately after the material set, following seven days of wet storage using three-point compression loading. The results were analyzed with an analysis of variance (ANOVA). Fracture resistance of the specimens was statistically different (p fibers showed higher transverse strength (149.82 MPa). The fiber reinforcement of resin materials increased the strength values (20-50%). Within the limitations of this study, the transverse strengths of PMMA, PEMA and BIS acryl-resin composites were improved after reinforcement with glass and aramid fibers.

  19. Potentiometric stripping analysis of lead and cadmium leaching from dental prosthetic materials and teeth

    Directory of Open Access Journals (Sweden)

    GORAN M. NIKOLIC

    2004-07-01

    Full Text Available Potentiometric stipping analysis (PSA was applied for the determination of lead and cadmium leaching from dental prosthetic materials and teeth. The soluble lead content in finished dental implants was found to be much lower than that of the individual components used for their preparation. Cadmium was not detected in dental implants and materials under the defined conditions. The soluble lead and cadmium content of teeth was slightly lower than the lead and cadmium content in whole teeth (w/w reported by other researchers, except in the case of a tooth with removed amalgam filling. The results of this work suggest that PSA may be a good method for lead and cadmium leaching studies for investigation of the biocompatibility of dental prosthetic materials.

  20. STUDY OF SURFACE PHENOMENA IN MATERIALS OF PROSTHETIC RESTORATION

    OpenAIRE

    Mihaela-Păpuşa Vasiliu; Carmen Stadoleanu; Daniela Ivona Tomiţa; Cristina-Mihaela Stanilă; S.-C. Jalbă; Nicoleta Dumitraşcu

    2012-01-01

    As a direct consequence of their application domain – the oral cavity – dental materials are subjected to the corosive action of saliva, being surrounded by microorganisms, fluids and alimentary rests, which modify their surface characteristics. Concerns on the quality of the dental materials explain the numeorus interdisciplinary studies, characterized by a close relation among various scientific domains (physics, chemistry, biology, science of biomaterials), techniqu...

  1. Comparison of temperature rise in pulp chamber during polymerization of materials used for direct fabrication of provisional restorations: An in-vitro study.

    Science.gov (United States)

    Khajuria, Rajat R; Madan, Ravi; Agarwal, Swatantra; Gupta, Reecha; Vadavadgi, Sunil V; Sharma, Vikas

    2015-01-01

    The purpose is to compare temperature rise in the pulp chamber during fabrication of provisional crowns using different materials and on different types of teeth using direct technique. An extracted, sound, caries free maxillary central incisor and a mandibular molar were selected for the study and crown preparations of all ceramic and all metal were done on central incisor and mandibular molar, respectively. Materials tested were DPI tooth molding self-curing material and protemp-4. Addition silicone putty was used as a matrix and 80 provisional crowns were fabricated, of which 40 were on central incisor and 40 on mandibular molar. Depending on the type of material used, they were further divided into two subgroups: Each comprising 20 provisional crowns. Temperature readings were recorded using K type of thermocouple with 0.1°C precision digital thermometer. Analysis of variance, Tukey honest significant difference and Kruskall-Wallis H-test. Statistically significant difference exists between two materials tested on the basis of peak temperature achieved and time taken by a particular material to reach peak temperature. Peak temperature achieved was highest for provisional crowns with DPI tooth molding self-curing material on maxillary central incisor (40.39 + 0.46), followed by DPI tooth molding self-curing material on mandibular molar (40.03 + 0.32), protemp-4 on maxillary central incisor (39.46 + 0.26) and least with protemp-4 on mandibular molar (39.09 + 0.33). The time taken to reach peak temperature was almost double in DPI tooth molding self-curing material (5 min) than in protemp-4. Polymethyl methacrylate resin produced higher intra-pulpal rise when compared to newer generation bis-acrylic composite.

  2. An in-vitro study of the effects of various disinfectants on prosthetic and surface materials.

    Science.gov (United States)

    Bahannan, Salma A; Abdel-Salam, Maha M

    2002-04-01

    This study assessed the effect of various disinfectants on several contaminated prosthetic and surface-covering materials. The efficacy of 6 disinfectants used at King Abdulaziz University, Jeddah, Kingdom of Saudi Arabia, on prosthetic and surface-covering materials, irreversible hydrocolloid and elastomer impression materials, wax, acrylic resin, metal, bench-covering material, and floor carpet. These materials were contaminated with Pseudomonas aeruginosa, Escherichia coli, and Staphylococcus aureus. Counts of viable bacteria on the materials was determined by incubated replica plating on blood agar plates at 5 minute intervals. A 3 way non parametric analysis of variance was used to evaluate the main effects and interactions of the disinfectants, bacteria, and materials. Statistical analysis showed that material, type of disinfectant, and interactions between material and bacteria were significant. Carpet has a significantly higher bacterial count than many other items (P bench surfaces. Quaternary ammonia compound and the tertiary ammonia phenol were the most effective disinfectants. Efficacy of the disinfectant depends partly on the bacteria used for contamination. Carpets in dental clinics showed high potential to retain microorganisms.

  3. Adsorption of albumin on prosthetic materials: implication for tribological behavior.

    Science.gov (United States)

    Serro, A P; Gispert, M P; Martins, M C L; Brogueira, P; Colaço, R; Saramago, B

    2006-09-01

    The orthopedic prosthesis used to substitute damaged natural joints are lubricated by a pseudosynovial fluid that contains biological macromolecules with potential boundary lubrication properties. Proteins are some of those macromolecules whose role in the lubrication process is not yet completely understood. In a previous work, we investigated the influence of the presence of albumin, the major synovial protein, upon the tribological behavior of three of the most used pairs of artificial joint materials: ultra high molecular weight polyethylene (UHMWPE) against counterfaces of alumina, CoCrMo alloy, and 316L stainless steel. Albumin was found to cause a significant decrease in the friction coefficient when the counterfaces were metallic because transfer of UHMWPE was avoided, but this effect was much weaker in the case of alumina. The objective of the present work was to look for an explanation for these differences in tribological behavior in terms of albumin adsorption. With this goal, studies on adsorption of bovine serum albumin (BSA) on the counterface materials, from a biological model fluid (Hanks' balanced salt solution), were carried out using radiolabeled albumin ((125)I-BSA), X-ray photoelectron spectroscopy, and atomic force microscopy. The conclusion from all techniques is that the driving force for albumin adsorption is higher on the metals than on alumina. These results confirm that the greater the amount of protein adsorbed on the counterface, the more efficient is the protection against the transfer of polymeric film to the counterface.

  4. Evaluation of the flexural strength and microhardness of provisional crown and bridge materials fabricated by different methods.

    Science.gov (United States)

    Digholkar, Shruti; Madhav, V N V; Palaskar, Jayant

    2016-01-01

    The purpose of this study was to evaluate and compare the flexural strength and microhardness of provisional restorative materials fabricated utilizing rapid prototyping (RP), Computer Assisted Designing and Computer Assisted Milling (CAD-CAM) and conventional method. Twenty specimens of dimensions 25 mm × 2 mm × 2 mm (ADA-ANSI specification #27) were fabricated each using: (1) Three dimensional (3D) printed light-cured micro-hybrid filled composite by RP resin group, (2) a milled polymethyl methacrylate (CH) using CAD-CAM (CC resin group), and (3) a conventionally fabricated heat activated polymerized CH resin group. Flexural strength and microhardness were measured and values obtained were evaluated. The measured mean flexural strength values (MegaPascals) were 79.54 (RP resin group), 104.20 (CC resin group), and 95.58 (CH resin group). The measured mean microhardness values (Knoop hardness number) were 32.77 (RP resin group), 25.33 (CC resin group), and 27.36 (CH resin group). The analysis of variance (ANOVA) test shows that there is statistically significant difference in the flexural strength values of the three groups (P microhardness values of the three groups was statistically significant according to ANOVA as well as the intergroup comparison done using the Tukey's HSD (post hoc) test (P microhardness.

  5. Mechanical properties of four methylmethacrylate-based resins for provisional fixed restorations.

    Science.gov (United States)

    Hernandez, E P; Oshida, Y; Platt, J A; Andres, C J; Barco, M T; Brown, D T

    2004-01-01

    The use of a provisional restoration is an important phase in the treatment of the dental prosthetic patient. A good provisional restoration should satisfy the following requirements: pulpal protection, positional stability, ease in cleaning, accurate margins, wear resistance, dimensional stability, and serve as a diagnostic aid in treatment assessment and esthetics. There is a tendency for discoloration, occlusal wear, and fracture that eventually leads to unnecessary repair. Heat-processed and reinforced methacrylate-based resins have been used to improve the mechanical and physical properties of provisional restorations. Among various improvements, the interpenetrating network crosslinked PMMA (IPN) has been shown to have superior mechanical properties if manufactured through a dough compression molding process at 130 degrees C. However, there have been no published data that relate with the use of this material for fixed provisional restorations. The objective of this study was to compare four methyl methacrylate-based resins for provisional crowns and bridges with varying processing cycles, including JET [self-cure], ACRALON [heat-cured], titanium dioxide filled PMMA [heat-cured], and IPN [heat-cured denture tooth resin]. Properties studied included transverse strength, toughness, rigidity, and hardness. From the results of this study the following conclusions can be made: the IPN group may have had a lower degree of conversion as demonstrated by decreased strength, toughness, and hardness data as compared with Acralon. Increasing the polymerization cycle of unmodified Acralon resin causes a significant increase in strength.

  6. PROSTHETIC ARTERIES—Resection of the Abdominal Aorta and Replacement with Plastic Materials

    Science.gov (United States)

    Miller, Arthur C.; Michals, Arnold A.; Auvil, Raymond G.

    1958-01-01

    In seven cases, nine operations were done in which arterial replacements made of synthetic fabrics were used. In three cases the operation was entirely elective, and at last report the patients were doing well. In the four other cases there were acutely complicating factors, known before operation, and the patients died although so far as functioning of the prosthetic artery was concerned there was difficulty in only one case—a leak at one of the anastomotic seams. In one case in which the synthetic material was removed after it had been in place some time, the prosthesis showed little effect of foreign body reaction. PMID:13500213

  7. Tensile strength and impact resistance properties of materials used in prosthetic check sockets, copolymer sockets, and definitive laminated sockets.

    Science.gov (United States)

    Gerschutz, Maria J; Haynes, Michael L; Nixon, Derek M; Colvin, James M

    2011-01-01

    Prosthetic sockets serve as the interface between people with amputations and their prostheses. Although most materials used to make prosthetic sockets have been used for many years, knowledge of these materials' properties is limited, especially after they are subjected to fabrication processes. This study evaluated tensile and impact properties of the current state-of-the-art materials used to fabricate prosthetic check sockets, copolymer sockets, and definitive laminated sockets. Thermolyn Rigid and Orfitrans Stiff check socket materials produced significantly lower tensile strength and impact resistance than polyethylene terephthalate glycol (PETG). Copolymer socket materials exhibited greater resistance to impact forces than the check socket materials but lower tensile strengths than PETG. The heated molding processes, for the check socket and copolymer materials, reduced both tensile strength and elongation at break. Definitive laminated sockets were sorted according to fabrication techniques. Nyglass material had significantly higher elongation, indicating a more ductile material than carbon-based laminations. Carbon sockets with pigmented resin had higher tensile strength and modulus at break than nonpigmented carbon sockets. Elongation at yield and elongation at break were similar for both types of carbon-based laminations. The material properties determined in this study provide a foundation for understanding and improving the quality of prosthetic sockets using current fabrication materials and a basis for evaluating future technologies.

  8. FEM and Von Mises Analysis on Prosthetic Crowns Structural Elements: Evaluation of Different Applied Materials

    Directory of Open Access Journals (Sweden)

    Ennio Bramanti

    2017-01-01

    Full Text Available The aim of this paper is to underline the mechanical properties of dental single crown prosthodontics materials in order to differentiate the possibility of using each material for typical clinical condition and masticatory load. Objective of the investigation is to highlight the stress distribution over different common dental crowns by using computer-aided design software and a three-dimensional virtual model. By using engineering systems of analyses like FEM and Von Mises investigations it has been highlighted the strength over simulated lower first premolar crowns made by chrome cobalt alloy, golden alloy, dental resin, and zirconia. The prosthodontics crown models have been created and put on simulated chewing stresses. The three-dimensional models were subjected to axial and oblique forces and both guaranteed expected results over simulated masticatory cycle. Dental resin presented the low value of fracture while high values have been recorded for the metal alloy and zirconia. Clinicians should choose the better prosthetic solution for the teeth they want to restore and replace. Both prosthetic dental crowns offer long-term success if applied following the manufacture guide limitations and suggestions.

  9. Deposit buildup on prosthetic eye material (in vitro) and its effect on surface wettability.

    Science.gov (United States)

    Pine, Keith Raymond; Sloan, Brian; Han, Kyuyeon Ivy; Swift, Simon; Jacobs, Robert John

    2013-01-01

    The aim of this in-vitro study was to investigate the effect of different polishing standards on prosthetic eye material (poly(methyl methacrylate) [PMMA]) on surface wettability and the rate of protein and lipid buildup. Sample disks (12 mm diameter × 1 mm thickness) of PMMA were polished to three different standards of surface finish: low, normal, and optical quality contact lens standard. The sample disks were incubated in a protein-rich artificial tear solution (ATS) for the following periods of time: 1 second, 30 minutes, 1 hour, 4 hours, 24 hours, and 14 days. Surface wettability was measured with a goniometer before and after protein deposits were removed. One-way analysis of variance and paired-samples t-test were used for the statistical analysis. Between 13.64 and 62.88 μg of protein adhered to the sample disks immediately upon immersion in ATS. Sample disks with the highest polish attracted less protein deposits. The sample disks polished to optical quality contact lens standard were more wettable than those less highly polished, and wettability significantly decreased following removal of protein deposits. The addition of lipids to protein-only ATS made no difference to the amount of protein deposited on the sample disks for any of the standards of surface polish tested. The findings are consistent with the results of the in-vivo investigation reported previously by the authors. Our view that the minimum standard of polish for prosthetic eyes should be optical quality contact lens standard and that deposits on PMMA prosthetic eyes improve the lubricating properties of the socket fluids has been reinforced by the results of this study.

  10. Evaluation of Bond Strength between Grooved Titanium Alloy Implant Abutments and Provisional Veneering Materials after Surface Treatment of the Abutments: AnIn vitroStudy.

    Science.gov (United States)

    Venkat, Gowtham; Krishnan, Murugesan; Srinivasan, Suganya; Balasubramanian, Muthukumar

    2017-01-01

    Titanium has become the material of choice with greater applications in dental implants. The success of the dental implant does not only depend on the integration of the implant to the bone but also on the function and longevity of the superstructure. The clinical condition that demands long-term interim prosthesis is challenging owing to the decreased bond between the abutment and the veneering material. Hence, various surface treatments are done on the abutments to increase the bond strength. This study aimed to evaluate the bond strength between the abutment and the provisional veneering materials by surface treatments such as acid etching, laser etching, and sand blasting of the abutment. Forty titanium alloy abutments of 3 mm diameter and 11 mm height were grouped into four groups with ten samples. Groups A, B, C, and D are untreated abutments, sand blasted with 110 μm aluminum particles, etched with 1% hydrofluoric acid and 30% nitric acid, and laser etched with Nd: YAG laser, respectively. Provisional crowns were fabricated with bis-acrylic resin and cemented with noneugenol temporary luting cement. The shear bond strength was measured in universal testing machine using modified Shell-Nielsen shear test after the cemented samples were stored in water at 25°C for 24 h. Load was applied at a constant cross head speed of 5 mm/min until a sudden decrease in resistance indicative of bond failure was observed. The corresponding force values were recorded, and statistical analysis was done using one-way ANOVA and Newman-Keuls post hoc test. The laser-etched samples showed higher bond strength. Among the three surface treatments, laser etching showed the highest bond strength between titanium alloy implant abutment and provisional restorations. The sand-blasted surfaces demonstrated a significant difference in bond strength compared to laser-etched surfaces. The results of this study confirmed that a combination of surface treatments and bond agents enhances the

  11. Deposit buildup on prosthetic eye material (in vitro and its effect on surface wettability

    Directory of Open Access Journals (Sweden)

    Pine KR

    2013-02-01

    Full Text Available Keith Raymond Pine,1 Brian Sloan,2 KyuYeon Ivy Han,1 Simon Swift,3 Robert John Jacobs11Department of Optometry and Vision Science, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand; 2New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand; 3Department of Molecular Medicine and Pathology, School of Medical Sciences, The University of Auckland, Auckland, New ZealandBackground: The aim of this in-vitro study was to investigate the effect of different polishing standards on prosthetic eye material (poly(methyl methacrylate [PMMA] on surface wettability and the rate of protein and lipid buildup.Methods: Sample disks (12 mm diameter × 1 mm thickness of PMMA were polished to three different standards of surface finish: low, normal, and optical quality contact lens standard. The sample disks were incubated in a protein-rich artificial tear solution (ATS for the following periods of time: 1 second, 30 minutes, 1 hour, 4 hours, 24 hours, and 14 days. Surface wettability was measured with a goniometer before and after protein deposits were removed. One-way analysis of variance and paired-samples t-test were used for the statistical analysis.Results: Between 13.64 and 62.88 µg of protein adhered to the sample disks immediately upon immersion in ATS. Sample disks with the highest polish attracted less protein deposits. The sample disks polished to optical quality contact lens standard were more wettable than those less highly polished, and wettability significantly decreased following removal of protein deposits. The addition of lipids to protein-only ATS made no difference to the amount of protein deposited on the sample disks for any of the standards of surface polish tested.Conclusion: The findings are consistent with the results of the in-vivo investigation reported previously by the authors. Our view that the minimum standard of polish for prosthetic eyes should be optical quality contact

  12. Evaluation of bond strength between grooved titanium alloy implant abutments and provisional veneering materials after surface treatment of the abutments: An in vitro study

    Directory of Open Access Journals (Sweden)

    Gowtham Venkat

    2017-01-01

    Full Text Available Introduction: Titanium has become the material of choice with greater applications in dental implants. The success of the dental implant does not only depend on the integration of the implant to the bone but also on the function and longevity of the superstructure. The clinical condition that demands long-term interim prosthesis is challenging owing to the decreased bond between the abutment and the veneering material. Hence, various surface treatments are done on the abutments to increase the bond strength. Aim: This study aimed to evaluate the bond strength between the abutment and the provisional veneering materials by surface treatments such as acid etching, laser etching, and sand blasting of the abutment. Materials and Methods: Forty titanium alloy abutments of 3 mm diameter and 11 mm height were grouped into four groups with ten samples. Groups A, B, C, and D are untreated abutments, sand blasted with 110 μm aluminum particles, etched with 1% hydrofluoric acid and 30% nitric acid, and laser etched with Nd: YAG laser, respectively. Provisional crowns were fabricated with bis-acrylic resin and cemented with noneugenol temporary luting cement. The shear bond strength was measured in universal testing machine using modified Shell–Nielsen shear test after the cemented samples were stored in water at 25°C for 24 h. Load was applied at a constant cross head speed of 5 mm/min until a sudden decrease in resistance indicative of bond failure was observed. The corresponding force values were recorded, and statistical analysis was done using one-way ANOVA and Newman–Keuls post hoc test. Results: The laser-etched samples showed higher bond strength. Conclusion: Among the three surface treatments, laser etching showed the highest bond strength between titanium alloy implant abutment and provisional restorations. The sand-blasted surfaces demonstrated a significant difference in bond strength compared to laser-etched surfaces. The results of this

  13. Evaluation of Vertical Marginal Adaptation of Provisional Crowns by ...

    African Journals Online (AJOL)

    2018-01-30

    Jan 30, 2018 ... Department of Prosthetic Dental Sciences, College of Dentistry,. King Saud University, Riyadh, Kingdom of Saudi Arabia. E‑mail: malrifaiy@hotmail.com. How to cite this article: Al Rifaiy MQ. Evaluation of vertical marginal adaptation of provisional crowns by digital microscope. Niger J Clin Pract. 2017 ...

  14. Impact of prosthetic material on mid- and long-term outcome of dental implants supporting single crowns and fixed partial dentures: A systematic review and meta-analysis.

    Science.gov (United States)

    Abou-Ayash, Samir; Strasding, Malin; Rücker, Gerta; Att, Wael

    2017-01-01

    The impact of prosthetic material selection on implant survival is not clear. The current criteria for choosing a prosthetic material seem to be based on clinician preferences. This systematic review aims to evaluate the impact of restorative materials on the mid- and long-term survival of implants supporting single crowns and fixed partial dentures. Hand and MEDLINE searches were performed to identify relevant literature for single crowns (SC) and fixed partial dentures (FPD). Further inclusion criteria were a mean follow-up period of at least 3 years, the inclusion of at least 10 patients in a relevant study cohort, and a clear description of prosthesis type and prosthetic material. A total of 63 studies for the SC group and 11 studies for the FPD group were included. Full arch restorations were not included. The materials utilised in the SC group were metal-ceramic (precious and non-precious), lithium-disilicate, veneered zirconia, veneered alumina, and nanoceramics. The materials used in the FPD group were metal-ceramic (precious), veneered titanium, metal-resin (precious), and veneered zirconia. No significant impact on the prosthetic material relating to mid- or long-term implant survival was identified. Furthermore, there were no statistically significant differences between the survival rates of the dental prostheses made from different materials (SC and FPD group). Single crowns made of nanoceramics showed a higher risk for decementation relative to other materials (0.80, 95% CI [0.67; 0.89]; P material selection has no influence on mid- and long-term survival of implants restored with single crowns and fixed partial dentures. Similarly, the prosthetic material seems to have no significant impact on prosthetic survival rates. Further research is required to provide more evidence regarding the impact of the prosthetic material on long-term outcome. Conflict-of-interest statement: The authors declare that they have no conflict of interest.

  15. Multifactorial analysis of variables influencing the fracture strength of repair joints for provisional restorative materials using the statistically based Taguchi method

    Directory of Open Access Journals (Sweden)

    Chun-Jen Cheng

    2010-06-01

    Conclusion: Within the limitations of this study, these four design factors had different contributions to the fracture strength of repaired provisional restorations. Clinicians must be aware of the sequence of importance in determining better problem-solving methods.

  16. Rehabilitation and Prosthetic Services

    Science.gov (United States)

    ... Sensory Aids Service » Prosthetic & Sensory Aids Service (PSAS) Rehabilitation and Prosthetic Services Menu Menu Rehabilitation and Prosthetics Rehabilitation and Prosthetic Services Home Amputation ...

  17. Total cavopulmonary direct anastomosis in the beating heart without prosthetic material: preliminary experience with modified extracardiac fontan procedure.

    Science.gov (United States)

    Xing, Quansheng; Shi, Lei; Han, Li; Wu, Qin

    2013-09-01

    To describe modified extracardiac Fontan procedure characterized with total cavopulmonary direct anastomosis in the beating heart without using prosthetic material in seven patients and summarize the clinical experiences and follow-up results. From April 2007 to April 2011, seven patients with complex cardiac anomalies underwent this operation. The main pulmonary artery (MPA) was transected at the base of the pulmonary valve and the pulmonary annulus was oversewn. Then the inferior vena cava (ICV) was transected at the junction with the atrium. The MPA was brought to the side of the ICV and anastomosed in an end-to-end fashion. The superior vena cava (SVC) was transected at its entrance into the right atrium and was anastomosed to the right pulmonary artery. Five patients received transcatheter device closure of the fenestration with either a small atrial septal defect or ventricular septal defect occluder. All patients were in sinus rhythm and extubated on the first postoperative day. Immediate postoperative arterial oxygen saturation was 95% (93% to 96%). During the follow-up period from 17 to 65 months (median 48 months), there were no deaths and reoperations. Arterial oxygen saturation ranged from 88% to 92% on room air. The fenestration was closed in five patients postoperatively and the arterial oxygen saturation rose to 95%. Total cavopulmonary direct anastomosis in the beating heart without the use of prosthetic material provides growth potential, and avoids the need for anticoagulation. Longer follow-up will be necessary to evaluate this modification. © 2013 Wiley Periodicals, Inc.

  18. Generalized provisional seed zones for native plants

    Science.gov (United States)

    Andrew D. Bower; J. Bradley St.Clair; Vicky. Erickson

    2014-01-01

    Deploying well-adapted and ecologically appropriate plant materials is a core component of successful restoration projects. We have developed generalized provisional seed zones that can be applied to any plant species in the United States to help guide seed movement. These seed zones are based on the intersection of high-resolution climatic data for winter minimum...

  19. Lactobacillus endocarditis with prosthetic material: a case report on non-surgical management with corresponding literature review

    Directory of Open Access Journals (Sweden)

    Mena Botros

    2014-08-01

    Full Text Available Lactobacilli are rod shaped gram positive bacteria that naturally colonize the human gastrointestinal and genitourinary tracts and occasionally cause disease in humans. Lactobacillus infections are found in patients who are immunocompromized or have severe comorbidities. We report Lactobacillus endocarditis in a 17-year-old adolescent girl with cardiac prosthetic material following surgical correction for complex cyanotic congenital heart disease. Accurate identification of the organism can be delayed. Despite in vivo susceptibility to vancomycin, our patient clinically failed vancomycin therapy but ultimately responded to a six-week course of penicillin, in addition to a 4-week course of clindamycin and gentamicin. She recovered without the need for surgical intervention and has been symptom free for one year. Upon review of the literature, we found that Lactobacillus endocarditis has not been reported in a pediatric patient with complex cyanotic congenital heart disease.

  20. Effect of prosthetic material on adhesion formation after laparoscopic ventral hernia repair in a porcine model.

    Science.gov (United States)

    Borrazzo, E C; Belmont, M F; Boffa, D; Fowler, D L

    2004-05-01

    Intraperitoneal placement of prosthetic mesh causes adhesion formation after laparoscopic incisional hernia repair. A prosthesis that prevents or reduces adhesion formation is desirable. In this study, 21 pigs were randomized to receive laparoscopic placement of plain polypropylene mesh (PPM), expanded polytetrafluoroethylene (ePTFE), or polypropylene coated on one side with a bioresorbable adhesion barrier (PPM/HA/CMC). The animals were sacrificed after 28 days and evaluated for adhesion formation. Mean area of adhesion formation was 14% (SD+/-15) in the PPM/HA/CMC group, 40% (SD+/-17) in the PPM group, and 41% (SD+/-39) in the ePTFE group. The difference between PPM/HA/CMC and PPM was significant ( P=0.013). A new visceral layer of mesothelium was present in seven out of seven PPM/HA/CMC cases, six out of seven PPM cases, and two out of seven ePTFE cases. Thus, laparoscopic placement of PPM/HA/CMC reduces adhesion formation compared to other mesh types used for laparoscopic ventral hernia repairs.

  1. Technology and the use of acrylics for provisional dentine protection.

    Science.gov (United States)

    Kapusevska, Biljana; Dereban, Nikola; Popovska, Mirjana; Nikolovska, Julijana; Radojkova Nikolovska, Vеrа; Zabokova Bilbilova, Efka; Mijoska, Aneta

    2013-01-01

    Acrylics are compounds polymerized from monomers of acrylic, metacrylic acid or acrylonitrates. The purpose of this paper is to present the technology and use of acrylics for provisional dentine protection in the practice of dental prosthodontics. For this reason, we followed 120 clinical cases from the everyday clinical practice, divided into 4 groups of 30 patients who needed prosthetic reconstruction. The first group included cases in which we applied celluloid crowns for dentine protection, for the second group we used acrylic teeth from a set of teeth for complete dentures; in the third and fourth groups the fabrication was done with the system of an impression matrix and the acrylic resin block technique respectively. In all the examined patients, the gingival index by Silness and Loe and the vitality of the dental pulp were verified clinically, after preparation and 8 days from the placement of the provisional crown. The value for dental sensitivity measured after preparation was 2.59, and 8 days after the placement of the provisional crown it bwas 3.1. From these results we can conclude that after the 8th day from the placement of the provisional crown, there was an adaptation period, characterized by a decrease in the painful sensations. The value of the Silness and Loe gingival index measured after the preparation was 1.34, and 8 days from the placement of the provisional crown was 0.94. The results inclined us to the fact that the provisional acrylic crowns facilitated the reparation of the periodontal tissue.

  2. Change in color of a maxillofacial prosthetic silicone elastomer, following investment in molds of different materials

    OpenAIRE

    Sethi, Tania; Kheur, Mohit; Coward, Trevor; Patel, Naimesha

    2015-01-01

    Purpose: In the authors? experience, the color of silicone elastomer following polymerization in molds made of gypsum products is slightly different from the color that was matched in the presence of the patient, before the silicone is packed. It is hypothesized that the investing materials and separating media have an effect on the color during the polymerization process of the silicone. Materials and Methods: This study compares and evaluates the change in color of silicone elastomer packed...

  3. Surface Coating of Gypsum-Based Molds for Maxillofacial Prosthetic Silicone Elastomeric Material: The Surface Topography.

    Science.gov (United States)

    Khalaf, Salah; Ariffin, Zaihan; Husein, Adam; Reza, Fazal

    2015-07-01

    This study aimed to compare the surface roughness of maxillofacial silicone elastomers fabricated in noncoated and coated gypsum materials. This study was also conducted to characterize the silicone elastomer specimens after surfaces were modified. A gypsum mold was coated with clear acrylic spray. The coated mold was then used to produce modified silicone experimental specimens (n = 35). The surface roughness of the modified silicone elastomers was compared with that of the control specimens, which were prepared by conventional flasking methods (n = 35). An atomic force microscope (AFM) was used for surface roughness measurement of silicone elastomer (unmodified and modified), and a scanning electron microscope (SEM) was used to evaluate the topographic conditions of coated and noncoated gypsum and silicone elastomer specimens (unmodified and modified) groups. After the gypsum molds were characterized, the fabricated silicone elastomers molded on noncoated and coated gypsum materials were evaluated further. Energy-dispersive X-ray spectroscopy (EDX) analysis of gypsum materials (noncoated and coated) and silicone elastomer specimens (unmodified and modified) was performed to evaluate the elemental changes after coating was conducted. Independent t test was used to analyze the differences in the surface roughness of unmodified and modified silicone at a significance level of p silicone elastomers processed against coated gypsum materials (p silicone elastomers. Silicone elastomers with lower surface roughness of maxillofacial prostheses can be obtained simply by coating a gypsum mold. © 2014 by the American College of Prosthodontists.

  4. Change in color of a maxillofacial prosthetic silicone elastomer, following investment in molds of different materials.

    Science.gov (United States)

    Sethi, Tania; Kheur, Mohit; Coward, Trevor; Patel, Naimesha

    2015-01-01

    In the authors' experience, the color of silicone elastomer following polymerization in molds made of gypsum products is slightly different from the color that was matched in the presence of the patient, before the silicone is packed. It is hypothesized that the investing materials and separating media have an effect on the color during the polymerization process of the silicone. This study compares and evaluates the change in color of silicone elastomer packed in three commonly used investing materials - Dental stone (white color), dental stone (green color), and die stone (orange color); coated with three different separating media - Alginate-based medium, soap solution and a resin-based die hardening material. Pigmented silicone samples of dimensions 1.5 cm × 2 cm × 0.5 cm were made from the elastomer in the above-mentioned mold materials using combinations of the mentioned separating media. These served as test group samples. Control group samples were made by packing a mix of the same pigmented elastomer in stainless steel molds. The L*, a*, b* values of the test and control group samples were determined using a spectrophotometer. The change in color (Delta E) was calculated between the control and test groups. The mean L, a, b values for the control group were, 31.8, 26.2, and 36.3, respectively. Average values of change in color (Delta E) for samples packed utilizing alginate-based medium, die hardener, and soap solution, respectively in white dental stone (2.70, 2.74, and 2.88), green dental stone (2.19, 2.23, 2.42), and orange die stone (3.19, 2.72, 2.80) were tabulated. Among the investing materials studied, die stone showed the most color change (3.19), which was statistically significant. Among the separating media, die hardener showed the least color change (2.23). The best combination of an investing material and separating media as per this investigation is a dental stone (green) and alginate-based separating medium.

  5. [Analysis and prevention of dust pollution caused by 5 common prosthetic materials].

    Science.gov (United States)

    Yang, Xiang-Wen; Wei, Bin; Zhu, Cao-Yun; Qian, Liang; Li, Yi-Han

    2017-10-01

    To analyze and evaluate dust pollution in prosthodontic clinic and make proposal for reasonable protection. This study analyzed the particle size, element composition and dust concentration of 5 materials which were commonly used in dental restorations (veneering ceramics, cobalt-chromium alloy, photosensitive plastic, hard base resin, advanced artificial teeth) by using scanning electron microscopy (SEM), X-ray energy dispersive spectrometer(EDS) and dust concentration laser tester, in order to assess the effects of prosthodontic dust posed on medical staff health and put forward reasonable suggestions for prevention and control of dust pollution. The particle size of veneering ceramics, cobalt-chromium alloy, photosensitive plastic, hard base resin and advanced artificial teeth was (2.15±3.00), (33.78±24.33), (7.78±11.86), (31.16±44.35) and (28.45±39.21)μm, respectively. The time weighted average respirable dust concentration of veneering ceramics was 0.393 mg/m2 which was beyond the scope of national security. Dust pollution is serious in prosthodontic clinic to which we should pay more attention and take appropriate prevention measures.

  6. Sequential provisional implant prosthodontics therapy.

    Science.gov (United States)

    Zinner, Ira D; Markovits, Stanley; Jansen, Curtis E; Reid, Patrick E; Schnader, Yale E; Shapiro, Herbert J

    2012-01-01

    The fabrication and long-term use of first- and second-stage provisional implant prostheses is critical to create a favorable prognosis for function and esthetics of a fixed-implant supported prosthesis. The fixed metal and acrylic resin cemented first-stage prosthesis, as reviewed in Part I, is needed for prevention of adjacent and opposing tooth movement, pressure on the implant site as well as protection to avoid micromovement of the freshly placed implant body. The second-stage prosthesis, reviewed in Part II, should be used following implant uncovering and abutment installation. The patient wears this provisional prosthesis until maturation of the bone and healing of soft tissues. The second-stage provisional prosthesis is also a fail-safe mechanism for possible early implant failures and also can be used with late failures and/or for the necessity to repair the definitive prosthesis. In addition, the screw-retained provisional prosthesis is used if and when an implant requires removal or other implants are to be placed as in a sequential approach. The creation and use of both first- and second-stage provisional prostheses involve a restorative dentist, dental technician, surgeon, and patient to work as a team. If the dentist alone cannot do diagnosis and treatment planning, surgery, and laboratory techniques, he or she needs help by employing the expertise of a surgeon and a laboratory technician. This team approach is essential for optimum results.

  7. 18F-FDG-PET/CT angiography in the diagnosis of infective endocarditis and cardiac device infection in adult patients with congenital heart disease and prosthetic material.

    Science.gov (United States)

    Pizzi, María N; Dos-Subirà, L; Roque, Albert; Fernández-Hidalgo, Nuria; Cuéllar-Calabria, Hug; Pijuan Domènech, Antonia; Gonzàlez-Alujas, María T; Subirana-Domènech, M T; Miranda-Barrio, B; Ferreira-González, Ignacio; González-López, Juan J; Igual, Albert; Maisterra-Santos, Olga; García-Dorado, David; Castell-Conesa, Joan; Almirante, Benito; Escobar Amores, Manuel; Tornos, Pilar; Aguadé-Bruix, Santiago

    2017-12-01

    Infective endocarditis (IE) and cardiac device infection (CDI) are a major complication in the growing number of patients with congenital heart disease (CHD) reaching adulthood. We aimed to evaluate the added value of 18F-FDG-PET/CT angiography (PET/CTA) in the diagnosis of IE-CDI in adults with CHD and intravascular or intracardiac prosthetic material, in whom echocardiography (ECHO) and modified Duke Criteria (DC) have limitations because of the patients' complex anatomy. A prospective study was conducted in a referral center with multidisciplinary IE and CHD Units. PET/CTA and ECHO findings were compared in consecutive adult (≥18years) patients with CHD who have prosthetic material and suspected IE-CDI. The initial diagnosis using the DC and the diagnosis with the additional PET/CTA data (DC+PET/CTA) were compared with the final diagnostic consensus established by an expert team at three months. Between November-2012 and April-2017, 25 patients (15 men; median age 40years) were included. Cases were initially classified as definite in 8 (32%), possible in 14 (56%) and rejected in 3 (12%). DC+PET/CTA allowed reclassification of 12/14 (86%) cases initially identified as possible IE. The sensitivity, specificity, PPV, NPV, and accuracy of DC at IE suspicion were 39.1%/83.3%/90.4%/25.5%/61.2%, respectively. The diagnostic performance increased significantly with addition of PET/CTA data: 87%/83.3%/95.4%/61.5%/85.1%, respectively. PET/CTA also provided an alternative diagnosis in 3 patients with rejected IE, and detected pulmonary embolisms in 3 patients. PET/CTA was a useful diagnostic tool in the complex group of adult patients with CHD who have cardiac or intravascular prosthetic material and suspected IE or CDI, providing added diagnostic value to the modified DC (increased sensitivity) and improving case classification. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  8. Antibacterial effect of polyethyleneimine nanoparticles incorporated in provisional cements against Streptococcus mutans.

    Science.gov (United States)

    Shvero, Dana Kesler; Davidi, Michael Perez; Weiss, Ervin I; Srerer, Nir; Beyth, Nurit

    2010-08-01

    Frequently provisional restorations require long-term permanence in the oral cavity, thus an antibacterial effect is desirable. We hypothesized that this effect may be achieved by incorporating polyethyleneimine (PEI) nanoparticles into provisional cements. The nanoparticles antibacterial effect incorporated at 0.5%, 1%, and 2% w/w into provisional cement, was studied in vitro. The antibacterial effect against Streptococcus mutans and Enterococcus faecalis was tested using direct contact test. The data was analyzed using the ANOVA test, with the Dunnett test for multiple pairwise comparisons. A strong antibacterial effect was evident in all test groups after an aging period of 14 days against S. mutans and E. faecalis (p faecalis (p faecalis for a period of 14 days. The minimum effective concentration suggested is 1% w/w. Incorporation of nanoparticles may prevent caries and inflammation, and thereby improve the results of the prosthetic treatment. Further investigation is necessary on the effect on mechanical properties and clinical relevance.

  9. Prosthetic stomatitis with removable dentures

    Directory of Open Access Journals (Sweden)

    Rozalieva Yu.Yu.

    2012-06-01

    Full Text Available The Research Objective: To study patients with prosthetic stomatitis, who use the removable laminar dentures. Materials: The consultations and treatment of 79 patients aged 47-65 years have been conducted. The patients have been divided into two clinical groups. The first clinical group (39 persons with the performance of immediate prosthet-ics; the second control clinical group (40 persons — the permanent dentures were produced without the preliminary instruction. Results: All the patients, having the laminar dentures without the preliminary use of immediate constructions of dentures, in spite of repeated correction of them, have had changes of dentures and transitory fold. Patients have been exposed to prosthetic stomatitis of different etiology (without trauma; the single-shot or multiple correction of dentures by the method of rebasing with using of cold cure plastics has been made. Conclusion: Structural and functional changes of dentition during the prosthetic stomatitis lead to disorders, associated by the mucositis. Use of the term of «prosthetic stomatitis» reflects etiological and pathogenetic component of changes in the denture-supporting tissues

  10. Occlusal wear of provisional implant-supported restorations

    NARCIS (Netherlands)

    Santing, Hendrik J.; Kleverlaan, Cornelis J.; Werner, Arie; Feilzer, Albert J.; Raghoebar, Gerry M.; Meijer, Henny J. A.

    BACKGROUND: Implant-supported provisional restorations should be resistant to occlusal wear. PURPOSE: The purpose of this laboratory study was to evaluate three-body wear of three indirect laboratory composite resins, five chair side bis-acryl resin-based materials, and two chair side

  11. Computer Aided Facial Prosthetics Manufacturing System

    Directory of Open Access Journals (Sweden)

    Peng H.K.

    2016-01-01

    Full Text Available Facial deformities can impose burden to the patient. There are many solutions for facial deformities such as plastic surgery and facial prosthetics. However, current fabrication method of facial prosthetics is high-cost and time consuming. This study aimed to identify a new method to construct a customized facial prosthetic. A 3D scanner, computer software and 3D printer were used in this study. Results showed that the new developed method can be used to produce a customized facial prosthetics. The advantages of the developed method over the conventional process are low cost, reduce waste of material and pollution in order to meet the green concept.

  12. A comparative study to check fracture strength of provisional fixed partial dentures made of autopolymerizing polymethylmethacrylate resin reinforced with different materials: An in vitro study

    Directory of Open Access Journals (Sweden)

    Parikshit Gupt

    2017-01-01

    Conclusion: Unidirectional glass fibers showed the maximum strength, which was comparable to mean values of both stainless steel wire groups. Low cost and easy technique of using stainless steel wire make it the material of choice over the unidirectional glass fiber for reinforcement in nonesthetic areas where high strength is required.

  13. Effect of different provisional cement remnant cleaning procedures including Er:YAG laser on shear bond strength of ceramics

    OpenAIRE

    Zortuk, Mustafa; Gumus, Hasan Onder; Kilinc, Halil Ibrahim; Tuncdemir, Ali Riza

    2012-01-01

    PURPOSE The purpose of this study was to evaluate the effect of provisional cement removal by different dentin cleaning protocols (dental explorer, pumice, cleaning bur, Er:YAG laser) on the shear bond strength between ceramic and dentin. MATERIALS AND METHODS In total, 36 caries-free unrestored human third molars were selected as tooth specimens. Provisional restorations were fabricated and cemented with eugenol-free provisional cement. Then, disc-shaped ceramic specimens were fabricated and...

  14. A technique for indirect fabrication of a complete-arch, implant-supported, fixed provisional restoration from a radiographic template.

    Science.gov (United States)

    Spyropoulou, Panagiota-Eirini; Razzoog, Michael; Sierraalta, Marianella

    2010-09-01

    This article describes an alternative technique for the fabrication of a complete-arch, implant-supported, cement-retained, fixed provisional restoration. The definitive cast is fabricated from the surgical guide and the provisional restoration is fabricated indirectly from the radiographic guide. This technique is an easy and time-saving procedure to fabricate an interim prosthesis for immediate or delayed loading of implants. Copyright © 2010 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  15. AI and Prosthetics

    OpenAIRE

    Kyriazi, Nefeli Evdokia

    2016-01-01

    Prosthetics are very important to an amputee.The introduction of technology to prosthetics has allowed bionic limbs to emerge and change the way we were thinking about prosthetic limbs.More and more companies create new innovative models,but not affordable for anyone.3D Printing gives more options.

  16. Threshold concepts in prosthetics

    OpenAIRE

    Hill, Sophie

    2016-01-01

    Background: Curriculum documents identify key concepts within learning prosthetics. Threshold concepts provide an alternative way of viewing the curriculum, focussing on the ways of thinking and practicing within prosthetics. Threshold concepts can be described as an opening to a different way of viewing a concept. This article forms part of a larger study exploring what students and staff experience as difficult in learning about prosthetics. Objectives: To explore possible thresh...

  17. Prevention of Prosthetic Dentistry

    Directory of Open Access Journals (Sweden)

    Eremin O.V.

    2011-03-01

    Full Text Available Prevention in prosthetic dentistry is not just a regular oral hygiene and the prevention of caries in the early stages of its development. The initial goal of orthopedic and dental should be the ability to convey to the patient's sense of pros-thetics that proteziruya one saved more. An example is included prosthetic dental arch defects with bridges or single artificial crowns on implants that will prevent movement of teeth and the continuity of the dentition

  18. Rapid Prototyping for In Vitro Knee Rig Investigations of Prosthetized Knee Biomechanics: Comparison with Cobalt-Chromium Alloy Implant Material

    Directory of Open Access Journals (Sweden)

    Christian Schröder

    2015-01-01

    Full Text Available Retropatellar complications after total knee arthroplasty (TKA such as anterior knee pain and subluxations might be related to altered patellofemoral biomechanics, in particular to trochlear design and femorotibial joint positioning. A method was developed to test femorotibial and patellofemoral joint modifications separately with 3D-rapid prototyped components for in vitro tests, but material differences may further influence results. This pilot study aims at validating the use of prostheses made of photopolymerized rapid prototype material (RPM by measuring the sliding friction with a ring-on-disc setup as well as knee kinematics and retropatellar pressure on a knee rig. Cobalt-chromium alloy (standard prosthesis material, SPM prostheses served as validation standard. Friction coefficients between these materials and polytetrafluoroethylene (PTFE were additionally tested as this latter material is commonly used to protect pressure sensors in experiments. No statistical differences were found between friction coefficients of both materials to PTFE. UHMWPE shows higher friction coefficient at low axial loads for RPM, a difference that disappears at higher load. No measurable statistical differences were found in knee kinematics and retropatellar pressure distribution. This suggests that using polymer prototypes may be a valid alternative to original components for in vitro TKA studies and future investigations on knee biomechanics.

  19. Threshold concepts in prosthetics.

    Science.gov (United States)

    Hill, Sophie

    2017-12-01

    Curriculum documents identify key concepts within learning prosthetics. Threshold concepts provide an alternative way of viewing the curriculum, focussing on the ways of thinking and practicing within prosthetics. Threshold concepts can be described as an opening to a different way of viewing a concept. This article forms part of a larger study exploring what students and staff experience as difficult in learning about prosthetics. To explore possible threshold concepts within prosthetics. Qualitative, interpretative phenomenological analysis. Data from 18 students and 8 staff at two universities with undergraduate prosthetics and orthotics programmes were generated through interviews and questionnaires. The data were analysed using an interpretative phenomenological analysis approach. Three possible threshold concepts arose from the data: 'how we walk', 'learning to talk' and 'considering the person'. Three potential threshold concepts in prosthetics are suggested with possible implications for prosthetics education. These possible threshold concepts involve changes in both conceptual and ontological knowledge, integrating into the persona of the individual. This integration occurs through the development of memories associated with procedural concepts that combine with disciplinary concepts. Considering the prosthetics curriculum through the lens of threshold concepts enables a focus on how students learn to become prosthetists. Clinical relevance This study provides new insights into how prosthetists learn. This has implications for curriculum design in prosthetics education.

  20. VSRR Provisional Drug Overdose Death Counts

    Data.gov (United States)

    U.S. Department of Health & Human Services — This data contains provisional counts for drug overdose deaths based on a current flow of mortality data in the National Vital Statistics System. National...

  1. Accuracy Verification of Magnetic Resonance Imaging (MRI Technology for Lower-Limb Prosthetic Research: Utilising Animal Soft Tissue Specimen and Common Socket Casting Materials

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Safari

    2012-01-01

    Full Text Available Lower limb prosthetic socket shape and volume consistency can be quantified using MRI technology. Additionally, MRI images of the residual limb could be used as an input data for CAD-CAM technology and finite element studies. However, the accuracy of MRI when socket casting materials are used has to be defined. A number of six, 46 mm thick, cross-sections of an animal leg were used. Three specimens were wrapped with Plaster of Paris (POP and the other three with commercially available silicone interface liner. Data was obtained by utilising MRI technology and then the segmented images compared to corresponding calliper measurement, photographic imaging, and water suspension techniques. The MRI measurement results were strongly correlated with actual diameter, surface area, and volume measurements. The results show that the selected scanning parameters and the semiautomatic segmentation method are adequate enough, considering the limit of clinical meaningful shape and volume fluctuation, for residual limb volume and the cross-sectional surface area measurements.

  2. The role of prosthetic abutment material on the stress distribution in a maxillary single implant-supported fixed prosthesis

    Energy Technology Data Exchange (ETDEWEB)

    Peixoto, Hugo Eduardo, E-mail: hugo.e.peixoto@hotmail.com [Implantology Team, Latin American Institute of Research and Education in Dentistry, Curitiba, Paraná (Brazil); Bordin, Dimorvan, E-mail: dimorvan_bordin@hotmail.com [Department of Prosthodontics and Periodontology, Piracicaba Dental School, State University of Campinas, Limeira avenue, 901-Vila Rezende, Piracicaba, SP 13414-903 (Brazil); Del Bel Cury, Altair A., E-mail: altcury@fop.unicamp.br [Department of Prosthodontics and Periodontology, Piracicaba Dental School, State University of Campinas, Limeira avenue, 901-Vila Rezende, Piracicaba, SP 13414-903 (Brazil); Silva, Wander José da, E-mail: wanderjose@fop.unicamp.br [Department of Prosthodontics and Periodontology, Piracicaba Dental School, State University of Campinas, Limeira avenue, 901-Vila Rezende, Piracicaba, SP 13414-903 (Brazil); Faot, Fernanda, E-mail: fernanda.faot@gmail.com [Department of Restorative Dentistry, School of Dentistry, Federal University of Pelotas, Gonçalves Chaves, 457, 2nd floor, Pelotas, Rio Grande do Sul 96015-560 (Brazil)

    2016-08-01

    Purpose: Evaluate the influence of abutment's material and geometry on stress distribution in a single implant-supported prosthesis. Materials and Methods: Three-dimensional models were made based on tomographic slices of the upper middle incisor area, in which a morse taper implant was positioned and a titanium (Ti) or zirconia (ZrN) universal abutments was installed. The commercially available geometry of titanium (T) and zirconia (Z) abutments were used to draw two models, TM1 and ZM1 respectively, which served as control groups. These models were compared with 2 experimental groups were the mechanical properties of Z were applied to the titanium abutment (TM2) and vice versa for the zirconia abutment (ZM2). Subsequently, loading was simulated in two steps, starting with a preload phase, calculated with the respective friction coefficients of each materials, followed by a combined preload and chewing force. The maximum von Mises stress was described. Data were analyzed by two-way ANOVA that considered material composition, geometry and loading (p < 0.05). Results: Titanium and zirconia abutments showed similar von Mises stresses in the mechanical part of the four models. The area with the highest concentration of stress was the screw thread, following by the screw body. The highest stress levels occurred in screw thread was observed during the preloading phase in the ZM1 model (931 MPa); and during the combined loading in the TM1 model (965 MPa). Statistically significant differences were observed for loading, the material × loading interaction, and the loading × geometry interaction (p < 0.05). Preloading contributed for 77.89% of the stress (p < 0.05). There were no statistically significant differences to the other factors (p > 0.05). Conclusion: The screw was the piece most intensely affected, mainly through the preload force, independent of the abutment's material. - Highlights: • The abutment's screw was the most impaired piece of the

  3. Use of intraoral welding to stabilize dental implants in augmented sites for immediate provisionalization: a case report.

    Science.gov (United States)

    Avvanzo, Pierluigi; Fabrocini, Lelio A; Ciavarella, Domenico; Avvanzo, Andrea; Lo Muzio, Lorenzo; De Maio, Raffaele A

    2012-02-01

    Immediate implant rehabilitation of edentulous arches may be somewhat problematic because of anatomic situations involving insufficient bone thickness or height and tooth position. The aim of this report was to present a retrospective case series of dental implants placed into augmented sites (split crest or sinus augmentation) that were stabilized with an intraorally welded framework at the time of immediate provisionalization. An intraoral welding unit was used to join and stabilize implants as an orthopedic splint to break down forces applied on provisional restorations during healing and osseointegration. This approach allows for the immediate provisionalization of implants in bone-defective areas where multiple implant systems have been enacted. Forty-eight implants in 16 patients were inserted, welded together to a titanium framework, and immediately provisionalized during the same surgery in which split-crest or sinus augmentation procedures were performed. After removing the welded frameworks, 1 of 48 implants failed; the failed implant was associated with a sinus augmentation procedure. Intraoral welding stabilization may be a predictable procedure to allow immediate loading in augmented areas during healing time and to stabilize implants against nonaxial forces, thereby reducing the number of surgical and prosthetic sessions and making patients comfortable and accustomed to immediate fixed provisional and definitive restorations.

  4. GIANT PROSTHETIC VALVE THROMBUS

    Directory of Open Access Journals (Sweden)

    Prashanth Kumar

    2015-04-01

    Full Text Available Mechanical prosthetic valves are predisposed to bleeding, thrombosis & thromboembolic complications. Overall incidence of thromboembolic complications is 1% per year who are on oral anticoagulants, whereas bleeding complications incidence is 0.5% to 6.6% per year. 1, 2 Minimization of Scylla of thromboembolic & Charybdis of bleeding complication needs a balancing act of optimal antithrombotic therapy. We are reporting a case of middle aged male patient with prosthetic mitral valve presenting in heart failure. Patient had discontinued anticoagulants, as he had subdural hematoma in the past. He presented to our institute with a giant prosthetic valve thrombus.

  5. The fixed/detachable implant provisional prosthesis.

    Science.gov (United States)

    Cibirka, R M; Linebaugh, M L

    1997-06-01

    Interim modification and management of a complete denture following surgical uncovering of dental implants can be time-intensive and may fail to provide adequate patient benefit until the definitive prosthesis can be completed. Inadequate interim management can result in functional and tissue difficulties. Modification of the conventional complete denture to a fixed/detachable provisional prosthesis in a one-stage procedure provides the patient an opportunity to experience a fixed prosthesis. The incorporation of fixed, provisional cylinders to the existing denture base using autopolymerizing acrylic resin with a closed-mouth technique is described. The peripheral regions are reduced and the distal extension shortened to resemble a fixed/detachable prosthesis. This conversion technique can provide patient satisfaction and comfort until delivery of the definitive prosthesis. Esthetic concerns, home care problems, or patient difficulties with the provisional prosthesis can be rectified in the final prosthesis.

  6. 14 CFR 121.207 - Provisionally certificated airplanes: Operating limitations.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Provisionally certificated airplanes... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Airplane Performance Operating Limitations § 121.207 Provisionally certificated airplanes: Operating limitations. In...

  7. VSRR - Provisional monthly number of live births by state

    Data.gov (United States)

    U.S. Department of Health & Human Services — https://www.cdc.gov/nchs/products/vsrr/provisional-tables.htm Monthly provisional counts of births are provided by state of residence (50 states, District of...

  8. VSRR - Provisional monthly number of deaths by state

    Data.gov (United States)

    U.S. Department of Health & Human Services — https://www.cdc.gov/nchs/products/vsrr/provisional-tables.htm Monthly provisional counts of deaths and infant deaths are provided by state of residence (50 states,...

  9. INTERACTIVE NAME PLACEMENT FOR PROVISIONAL MAPS.

    Science.gov (United States)

    Goldberg, Jeffrey L.; Miller, Thomas C.

    1983-01-01

    Computer generation and placement of map type has been refined into a production mode at Mid-Continent Mapping Center (MCMC) for USGS 1:24,000- and 1:25,000-scale Provisional maps. The map collar program is written in FORTRAN using batch processing that allows the program to work in the background.

  10. VSRR - Quarterly provisional estimates for infant mortality

    Data.gov (United States)

    U.S. Department of Health & Human Services — Provisional estimates of infant mortality (deaths of infants under 1 year per 1,000 live births), neonatal mortality (deaths of infants aged 0-27 days per 1,000 live...

  11. A study on provisional cements, cementation techniques, and their effects on bonding of porcelain laminate veneers.

    Science.gov (United States)

    Vinod Kumar, G; Soorya Poduval, T; Bipin Reddy; Shesha Reddy, P

    2014-03-01

    Minimal tooth preparation is required for porcelain laminate veneers, but interim restorations are a must to protect their teeth against thermal insult, chemical irritation, and to provide aesthetics. Cement remaining after the removal of the provisional restoration can impair the etching quality of the tooth surface and fit and final bonding of the porcelain laminate veneer. This in vitro study examined the tooth surface for remaining debris of cement after removal of a provisional restoration. Determine the presence of cement debris on prepared tooth surface subsequent to the removal of provisional restoration. Determine the cement with the least residue following the cleansing procedures. Determine the effect of smear layer on the amount of residual luting cement. Eighty-four extracted natural anterior teeth were prepared for porcelain laminate veneers. For half of the teeth, the smear layer was removed before luting provisional restorations. Veneer provisional restorations were fabricated and luted to teeth with six bonding methods: varnish combined with glass ionomer cement (GIC), varnish combined with resin modified GIC, varnish, spot etching combined with dual-cure luting cement, adhesive combined with GIC, adhesive combined with resin modified GIC, and adhesive, spot etching combined with dual-cure luting cement. After removal of provisional restorations 1 week later, the tooth surface was examined for residual luting material with SEM. Traces of cement debris were found on all the prepared teeth surfaces for all six groups which were cemented with different methods. Cement debris was seen on teeth subsequent to the removal of provisional's. Dual-cure cement had the least residue following the cleansing procedures. Presence of smear layer had no statistical significance in comparison with cement residue. With the use of adhesive the cement debris was always found to be more than with the use of varnish. GIC showed maximum residual cement followed by dual-cure.

  12. Occlusal concepts application in resolving implant prosthetic failure: case report.

    Science.gov (United States)

    Jamcoski, Vanessa Helena; Faot, Fernanda; de Mattias Sartori, Ivete Aparecida; Vieira, Rogéria Acedo; Tiossi, Rodrigo

    2014-04-01

    The prosthetic management of a poor implant treatment is presented in this case report. The recommended occlusion concepts for implant-supported prostheses were applied for the resolution of the case. The rehabilitation of the posterior segments provided a mutually protected occlusion with adequate distribution of the axial and lateral bite forces with stable posterior occlusion. The clinical exam indicated the need for modification in the vertical dimension of occlusion. Sufficient interocclusal rest space was present to test the alteration in the vertical dimension. The aim was to achieve an occlusion scheme that followed four specific criteria: (1) centric contacts and centric relation of the jaw-to-jaw position; (2) anterior guidance only; (3) shallow anterior angle of tooth contact; and (4) vertical dimension of occlusion with acceptable tooth form and guidance. The success of an oral rehabilitation relies in following the aforementioned criteria, appropriate interaction between the dental laboratory technician and the clinician, careful elaboration of the provisional rehabilitation with all the desired details to be reproduced in the final prosthetic restoration and sufficient follow-up time of the provisional prostheses before placing the final restoration.

  13. The dual-zone therapeutic concept of managing immediate implant placement and provisional restoration in anterior extraction sockets.

    Science.gov (United States)

    Chu, Stephen J; Salama, Maurice A; Salama, Henry; Garber, David A; Saito, Hanae; Sarnachiaro, Guido O; Tarnow, Dennis P

    2012-01-01

    Improvements in implant designs have helped advance successful immediate anterior implant placement into fresh extraction sockets. Clinical techniques described in this case enable practitioners to achieve predictable esthetic success using a method that limits the amount of buccal contour change of the extraction site ridge and potentially enhances the thickness of the peri-implant soft tissues coronal to the implant-abutment interface. This approach involves atraumatic tooth removal without flap elevation, and placing a bone graft into the residual gap around an immediate fresh-socket anterior implant with a screw-retained provisional restoration acting as a prosthetic socket seal device.

  14. Rotationally Actuated Prosthetic Hand

    Science.gov (United States)

    Norton, William E.; Belcher, Jewell G., Jr.; Carden, James R.; Vest, Thomas W.

    1991-01-01

    Prosthetic hand attached to end of remaining part of forearm and to upper arm just above elbow. Pincerlike fingers pushed apart to degree depending on rotation of forearm. Simpler in design, simpler to operate, weighs less, and takes up less space.

  15. Chairside preparation of provisional restorations.

    Science.gov (United States)

    Moy, Peter K; Parminter, Paul E

    2005-09-01

    Increasing demands are placed on the oral and maxillofacial surgeon to perform early or immediate loading of dental implants due to demands and expectations of the referring doctor and patients. In order to provide the patient with an immediately loaded, functioning implant, the surgeon should consider incorporating the fabrication of the temporary restoration as an additional service for their implant patients. The armamentarium necessary for the oral and maxillofacial surgeon to deliver a temporary restoration will be described. The materials and components needed to provide this service will be listed and a sequence of steps to easily accomplish the fabrication of a temporary crown will be presented. Temporary crowns cemented onto temporary or permanent implant abutments are ideal for the management of gingival contours. Initial soft tissue healing around the contours of the temporary crown, even with minimally invasive techniques, provides many advantages for the patient. There is less likelihood of gingival scarring, which minimizes the incidence of gingival recession and the patient is restored to normal form and function immediately. The fabrication of the temporary prosthesis by the oral and maxillofacial surgeon provides benefits for the surgeon, restorative doctor, as well as, the patient. By working closely with his or her restorative colleagues, the surgeon will be able to provide his or her implant patients with immediate return to form and function intraorally with minimum effort.

  16. A provisional fixed partial denture for an implant prosthesis.

    Science.gov (United States)

    Hansen, Paul A; Kim, Eunghwan

    2010-01-01

    This article presents a technique for fabricating an esthetic provisional restoration on multiple implants. Fabricating a provisional restoration allows the dentist to make a replica of the desired restoration. The incisal edge can be placed for esthetics and function in the new provisional restoration, allowing patients to evaluate comfort and test their ability to speak with the contour of the provisional restoration. Patients can evaluate both the ease of cleaning the restoration and how tissue esthetics can be duplicated to their satisfaction. By adding acrylic resin to or removing it from the provisional, the dentist can easily change the restoration until the patient is satisfied with the esthetic and functional result. This technique will allow the dentist to fabricate the provisional prosthesis quickly, while the patient is in the chair.

  17. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns

    Directory of Open Access Journals (Sweden)

    Adil Othman ABDULLAH

    Full Text Available ABSTRACT Objective This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. Material and Methods An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone “PEEK”, Telio CAD-Temp, and Protemp™4 (control group. The crowns were divided into four groups (n=10, Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. Results The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99 µm, PEEK 46.75 (±8.26 µm, Telio CAD-Temp 56.10 (±5.65 µm, and Protemp™4 193.07(±35.96 µm (P0.05. Conclusions CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns.

  18. Fixed and removable provisional options for patients undergoing implant treatment.

    Science.gov (United States)

    Cho, Sang-Choon; Shetty, Saphal; Froum, Stuart; Elian, Nicolas; Tarnow, Dennis

    2007-11-01

    The provisional phase of treatment can be the most challenging aspect of implant dentistry. The techniques available today include removable, tooth-supported, and implant-retained provisional restorations. The selection of the type of provisional prosthesis should be based on esthetic demands, functional requirements, duration, and ease of fabrication. This article includes a review of 118 articles from peer-reviewed journals published in English from January 1986 to February 2007. This review was performed using MEDLINE. The indications, advantages, and disadvantages of the various provisional restorations are discussed.

  19. Cortical neural prosthetics.

    Science.gov (United States)

    Schwartz, Andrew B

    2004-01-01

    Control of prostheses using cortical signals is based on three elements: chronic microelectrode arrays, extraction algorithms, and prosthetic effectors. Arrays of microelectrodes are permanently implanted in cerebral cortex. These arrays must record populations of single- and multiunit activity indefinitely. Information containing position and velocity correlates of animate movement needs to be extracted continuously in real time from the recorded activity. Prosthetic arms, the current effectors used in this work, need to have the agility and configuration of natural arms. Demonstrations using closed-loop control show that subjects change their neural activity to improve performance with these devices. Adaptive-learning algorithms that capitalize on these improvements show that this technology has the capability of restoring much of the arm movement lost with immobilizing deficits.

  20. Welding of Prosthetic Alloys

    Directory of Open Access Journals (Sweden)

    Wojciechowska M.

    2015-04-01

    Full Text Available This paper presents the techniques of joining metal denture elements, used in prosthetic dentistry: the traditional soldering technique with a gas burner and a new technique of welding with a laser beam; the aim of the study was to make a comparative assessment of the quality of the joints in view of the possibility of applying them in prosthetic structures. Fractographic examinations were conducted along with tensile strength and impact strength tests, and the quality of the joints was assessed compared to the solid metal. The experiments have shown that the metal elements used to make dentures, joined by the technique which employs a laser beam, have better strength properties than those achieved with a gas burner.

  1. The use of transitional implants to support provisional prostheses during the healing phase: a literature review.

    Science.gov (United States)

    de Almeida, Erika Oliveira; Filho, Homberto Gennari; Goiatto, Marcelo Coelho

    2011-01-01

    transitional implants are indicated for cases in which immediate loading is counterindicated because a healing period is necessary for osseointegration of the definitive implants. These provisional implants were developed to support an implant-supported fixed prosthesis or overdenture to provide retention, stability, and support. The aim of this article was to conduct a literature review on transitional implants to highlight the characteristics of the transitional implants and their advantages, indications, and contraindications, including the level of osseointegration of such implants according to the functional period. the present literature review was based on the Old Medline and Medline databases from 1999 to 2010 using the key words "transitional implants" and "temporary implants." Fourteen articles were found: 11 clinical studies or techniques and three histologic and histomorphometric studies. the transitional immediate prostheses were worn by completely and partially edentulous patients. Advantages of transitional implants include complete denture retention, stability, and support; maintenance of chewing, phonetics, and patient comfort; protection of bone grafts; vertical stop during healing period; easy and fast surgical and prosthetic procedures; lower cost in comparison to the definitive implant; and reestablishment of esthetics. The success of transitional implants as conservative treatment for conventional immediate loading is a reality if correctly indicated. transitional implants are a provisional treatment alternative for completely and partially edentulous patients. However, additional studies are required to evaluate the level of remodeling and repair of the transitional implants under loading.

  2. Prosthetic elbow joint

    Science.gov (United States)

    Weddendorf, Bruce C. (Inventor)

    1994-01-01

    An artificial, manually positionable elbow joint for use in an upper extremity, above-elbow, prosthetic is described. The prosthesis provides a locking feature that is easily controlled by the wearer. The instant elbow joint is very strong and durable enough to withstand the repeated heavy loadings encountered by a wearer who works in an industrial, construction, farming, or similar environment. The elbow joint of the present invention comprises a turntable, a frame, a forearm, and a locking assembly. The frame generally includes a housing for the locking assembly and two protruding ears. The forearm includes an elongated beam having a cup-shaped cylindrical member at one end and a locking wheel having a plurality of holes along a circular arc on its other end with a central bore for pivotal attachment to the protruding ears of the frame. The locking assembly includes a collar having a central opening with a plurality of internal grooves, a plurality of internal cam members each having a chamfered surface at one end and a V-shaped slot at its other end; an elongated locking pin having a crown wheel with cam surfaces and locking lugs secured thereto; two coiled compression springs; and a flexible filament attached to one end of the elongated locking pin and extending from the locking assembly for extending and retracting the locking pin into the holes in the locking wheel to permit selective adjustment of the forearm relative to the frame. In use, the turntable is affixed to the upper arm part of the prosthetic in the conventional manner, and the cup-shaped cylindrical member on one end of the forearm is affixed to the forearm piece of the prosthetic in the conventional manner. The elbow joint is easily adjusted and locked between maximum flex and extended positions.

  3. A COMPARATIVE STUDY ON THE EFFECTS OF THE POLYMER PROSTHETIC BASE PRESSURE OVER THE PROSTHETIC FIELD

    Directory of Open Access Journals (Sweden)

    A.T. Cigu

    2016-04-01

    Full Text Available Partially mobile polymeric prostheses constitute absolutely necessary therapeutical means in all forms of partial edentations. As known, polymeric partial prostheses constitute temporary solutions for the treatment of edentaton states. Nowadays, this treatment includes traditional acrylic prostheses, as well as elastic prostheses made of different material systems. Such a system is Valplast, which uses a polyamide for the realization of the prosthetic base. Both the rigid and the elastic materials are nowadays under debate, different – positive or negative – opinions being uttered in relation with their utilization. The scope of the present study is to support the intensive application of the elastic materials. Extremely important is the identification of the intrinsic qualities of the materials influencing the behaviour in the oral cavity, especially the effects of pressure upon the biological structures of the prosthetic field.

  4. 2012 Provisional classification criteria for polymyalgia rheumatica

    DEFF Research Database (Denmark)

    Dasgupta, Bhaskar; Cimmino, Marco A; Kremers, Hilal Maradit

    2012-01-01

    % and specificity to 81%. According to these provisional classification criteria, patients ≥50 years old presenting with bilateral shoulder pain, not better explained by an alternative pathology, can be classified as having PMR in the presence of morning stiffness >45 minutes, elevated C-reactive protein and......The objective of this study was to develop European League Against Rheumatism/American College of Rheumatology classification criteria for polymyalgia rheumatica (PMR). Candidate criteria were evaluated in a 6-month prospective cohort study of 125 patients with new-onset PMR and 169 non......-PMR comparison subjects with conditions mimicking PMR. A scoring algorithm was developed based on morning stiffness >45 minutes (2 points), hip pain/limited range of motion (1 point), absence of rheumatoid factor and/or anti-citrullinated protein antibody (2 points), and absence of peripheral joint pain (1 point...

  5. Instant loading with intraoral welding technique and PRAMA implants: a new prosthetic approach.

    Science.gov (United States)

    Celletti, R; Fanali, S; Laici, C U; Santori, C; Pignatelli, P; Sinjari, B

    2017-01-01

    When splinting multiple implants passive fit of the framework should be achieved to avoid excessive force distribution on the implants. Recently, a protocol was suggested for immediate loading of multiple implants by welding a titanium bar to implant abutments directly in the oral cavity so as to create a customized, precise and passive metal-reinforced provisional restoration. The intraoral welding technique subsequently proves to be a successful option in the full-arch immediate restorations of the mandible and maxilla. The aim of this article is to present a case report in which a new prosthetic approach, using trans-mucosal implants, is described. Dental implants are instantly loaded with a provisional prosthesis supported by an intraoral welded titanium framework to obtain a precise passive fit of the immediate loaded prosthesis.

  6. Effect of different provisional cement remnant cleaning procedures including Er:YAG laser on shear bond strength of ceramics

    Science.gov (United States)

    Zortuk, Mustafa; Gumus, Hasan Onder; Kilinc, Halil Ibrahim

    2012-01-01

    PURPOSE The purpose of this study was to evaluate the effect of provisional cement removal by different dentin cleaning protocols (dental explorer, pumice, cleaning bur, Er:YAG laser) on the shear bond strength between ceramic and dentin. MATERIALS AND METHODS In total, 36 caries-free unrestored human third molars were selected as tooth specimens. Provisional restorations were fabricated and cemented with eugenol-free provisional cement. Then, disc-shaped ceramic specimens were fabricated and randomly assigned to four groups of dentin cleaning protocols (n = 9). Group 1 (control): Provisional cements were mechanically removed with a dental explorer. Group 2: The dentin surfaces were treated with a cleaning brush with pumice Group 3: The dentin surfaces were treated with a cleaning bur. Group 4: The provisional cements were removed by an Er:YAG laser. Self-adhesive luting cement was used to bond ceramic discs to dentin surfaces. Shear bond strength (SBS) was measured using a universal testing machine at a 0.05 mm/min crosshead speed. The data were analyzed using a Kolmogorov Smirnov, One-way ANOVA and Tukey HSD tests to perform multiple comparisons (α=0.05). RESULTS The dentin cleaning methods did not significantly affect the SBS of ceramic discs to dentin as follows: dental explorer, pumice, cleaning bur, and Er:YAG laser. CONCLUSION The use of different cleaning protocols did not affect the SBS between dentin and ceramic surfaces. PMID:23236570

  7. VSRR - Quarterly provisional estimates for selected birth indicators

    Data.gov (United States)

    U.S. Department of Health & Human Services — Provisional estimates of selected reproductive indicators. Estimates are presented for: general fertility rates, age-specific birth rates, total and low risk...

  8. VSRR - Quarterly provisional estimates for selected indicators of mortality

    Data.gov (United States)

    U.S. Department of Health & Human Services — Provisional estimates of death rates. Estimates are presented for each of the 15 leading causes of death plus estimates for deaths attributed to drug overdose, falls...

  9. A prosthetic knee using magnetorhelogical fluid damper for above-knee amputees

    Science.gov (United States)

    Park, Jinhyuk; Choi, Seung-Bok

    2015-04-01

    A prosthetic knee for above-knee (AK) amputees is categorized into two types; namely a passive and an active type. The passive prosthetic knee is generally made by elastic materials such as carbon fiber reinforced composite material, titanium and etc. The passive prosthetic knee easy to walk. But, it has disadvantages such that a knee joint motion is not similar to ordinary people. On the other hand, the active prosthetic knee can control the knee joint angle effectively because of mechanical actuator and microprocessor. The actuator should generate large damping force to support the weight of human body. But, generating the large torque using small actuator is difficult. To solve this problem, a semi-active type prosthetic knee has been researched. This paper proposes a semi-active prosthetic knee using a flow mode magneto-rheological (MR) damper for AK amputees. The proposed semi-active type prosthetic knee consists of the flow mode MR damper, hinge and prosthetic knee body. In order to support weight of human body, the required energy of MR damper is smaller than actuator of active prosthetic leg. And it can control the knee joint angle by inducing the magnetic field during the stance phase.

  10. Innovación en la reconstrucción del pabellón auricular disgenésico con tejido expandido e implante Innovation in congenital auricular anomaly reconstruction using expanded tissue and prosthetic material

    Directory of Open Access Journals (Sweden)

    P. Iwanyk

    2007-06-01

    Full Text Available En la reconstrucción de un pabellón auricular disgenésico se plantean, básicamente, dos desafíos, reproducir un esqueleto cartilaginoso auricular de forma, tamaño y proyección similar al pabellón auricular normal, y obtener piel suficiente que combine color, textura y grosor semejante a la circundante. Debido a la escasa cantidad de piel útil en esta localización y a la dificultad en el tallado del esqueleto cartilaginoso auricular, iniciamos en 2005 en nuestro Hospital la reconstrucción auricular mediante combinación de tejidos expandidos locales y materiales protésicos, logrando un excelente resultado de apariencia natural.Reconstruction of congenital auricular anomalies includes two essential challenges. The first one is to sculpt an auricular cartilaginous structure that matches the shape, size and projection of a standard ear. The second challenge arises from the scarcity of the usable skin in the area. Because of the difficulty of sculpting a proper cartilage framework and the scarce quantity of skin in the area, in 2005 we began in our hospital auricular reconstruction procedure combining tissue expanders and prosthetic materials achieving a natural appearance and an excellent result.

  11. Prosthetic helping hand

    Science.gov (United States)

    Vest, Thomas W. (Inventor); Carden, James R. (Inventor); Norton, William E. (Inventor); Belcher, Jewell G. (Inventor)

    1992-01-01

    A prosthetic device for below-the-elbow amputees, having a C-shaped clamping mechanism for grasping cylindrical objects, is described. The clamping mechanism is pivotally mounted to a cuff that fits on the amputee's lower arm. The present invention is utilized by placing an arm that has been amputated below the elbow into the cuff. The clamping mechanism then serves as a hand whenever it becomes necessary for the amputee to grasp a cylindrical object such as a handle, a bar, a rod, etc. To grasp the cylindrical object, the object is jammed against the opening in the C-shaped spring, causing the spring to open, the object to pass to the center of the spring, and the spring to snap shut behind the object. Various sizes of clamping mechanisms can be provided and easily interchanged to accommodate a variety of diameters. With the extension that pivots and rotates, the clamping mechanism can be used in a variety of orientations. Thus, this invention provides the amputee with a clamping mechanism that can be used to perform a number of tasks.

  12. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns.

    Science.gov (United States)

    Abdullah, Adil Othman; Tsitrou, Effrosyni A; Pollington, Sarah

    2016-01-01

    This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone "PEEK", Telio CAD-Temp, and Protemp™4 (control group). The crowns were divided into four groups (n=10), Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99) µm, PEEK 46.75 (±8.26) µm, Telio CAD-Temp 56.10 (±5.65) µm, and Protemp™4 193.07(±35.96) µm (PCAD-Temp® 124.94 (±22.96) µm, PEEK 113.14 (±23.55) µm, Telio CAD-Temp 110.95 (±11.64) µm, and Protemp™4 143.48(±26.74) µm. The average fracture strength was: VITA CAD-Temp® 361.01 (±21.61) N, PEEK 802.23 (±111.29) N, Telio CAD-Temp 719.24 (±95.17) N, and Protemp™4 416.40 (±69.14) N. One-way ANOVA test showed a statistically significant difference for marginal gap, internal gap, and fracture strength between all groups (p0.05). CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns.

  13. Injectible bodily prosthetics employing methacrylic copolymer gels

    Energy Technology Data Exchange (ETDEWEB)

    Mallapragada, Surya K.; Anderson, Brian C.

    2007-02-27

    The present invention provides novel block copolymers as structural supplements for injectible bodily prosthetics employed in medical or cosmetic procedures. The invention also includes the use of such block copolymers as nucleus pulposus replacement materials for the treatment of degenerative disc disorders and spinal injuries. The copolymers are constructed by polymerization of a tertiary amine methacrylate with either a (poly(ethylene oxide)-b-poly(propylene oxide)-b-poly(ethylene oxide) polymer, such as the commercially available Pluronic.RTM. polymers, or a poly(ethylene glycol) methyl ether polymer.

  14. Comparative evaluation of marginal leakage of provisional crowns cemented with different temporary luting cements: In vitro study

    Science.gov (United States)

    Arora, Sheen Juneja; Arora, Aman; Upadhyaya, Viram; Jain, Shilpi

    2016-01-01

    Background or Statement of Problem: As, the longevity of provisional restorations is related to, a perfect adaptation and a strong, long-term union between restoration and teeth structures, therefore, evaluation of marginal leakage of provisional restorative materials luted with cements using the standardized procedures is essential. Aims and Objectives: To compare the marginal leakage of the provisional crowns fabricated from Autopolymerizing acrylic resin crowns and bisphenol A-glycidyl dimethacrylate (BIS-GMA) resin crowns. To compare the marginal leakage of the provisional crowns fabricated from autopolymerizing acrylic resin crowns and BIS-GMA resin crowns cemented with different temporary luting cements. To compare the marginal leakage of the provisional crowns fabricated from autopolymerizing acrylic resin (SC-10) crowns cemented with different temporary luting cements. To compare the marginal leakage of the provisional crowns fabricated from BIS-GMA resin crowns (Protemp 4) cemented with different temporary luting cements. Methodology: Freshly extracted 60 maxillary premolars of approximately similar dimensions were mounted in dental plaster. Tooth reduction with shoulder margin was planned to use a customized handpiece-holding jig. Provisional crowns were prepared using the wax pattern fabricated from computer aided designing/computer aided manufacturing milling machine following the tooth preparation. Sixty provisional crowns were made, thirty each of SC-10 and Protemp 4 and were then cemented with three different luting cements. Specimens were thermocycled, submerged in a 2% methylene blue solution, then sectioned and observed under a stereomicroscope for the evaluation of marginal microleakage. A five-level scale was used to score dye penetration in the tooth/cement interface and the results of this study was analyzed using the Chi-square test, Mann–Whitney U-test, Kruskal–Wallis H-test and the results were statistically significant P crowns

  15. The Design And Development Of Adjustable Prosthetic Device For A ...

    African Journals Online (AJOL)

    Using a six bar link knee mechanism an artificial adjustable leg is produced for an amputee. The prosthetic device when fitted to an amputee provided easy movement for the left leg amputee. It is produced using readily available materials involving aluminum, steel, polyethylene, leader, glue etc. the device has a special ...

  16. Candida infection of a prosthetic shoulder joint

    Energy Technology Data Exchange (ETDEWEB)

    Lichtman, E.A.

    1983-09-01

    A heroin addict developed a Candida parapsilosis infection in a prosthetic shoulder joint. Radiographs showed loose fragments of cement with prosthetic loosening. The patient was treated with removal of the prosthesis and intravenous amphotericin B followed by oral ketoconazole.

  17. Prosthetic Rehabilitation of Child Victim of Avulsion of Anterior Teeth with Orthodontic Mini-Implant

    Directory of Open Access Journals (Sweden)

    Natalice Sousa de Oliveira

    2017-01-01

    Full Text Available The treatment of choice in cases of avulsed permanent teeth is the immediate reimplantation. However, this conduct does not always work favorably, either by failures in the initial approach or by inappropriate interventions. In this sense, the aim of this study is to present an alternative prosthetic rehabilitation with the use of orthodontic mini-implants in the anterior region. This case reports a ten-year-old child with history of avulsion of superior central incisors. The therapeutic approach was planned to promote physiological teeth contacts and acceptable esthetics and phonetics. First, the occlusal-gingival insertion of two orthodontic mini-implants was performed in the alveolar ridge, and, immediately after that, two provisional crowns were attached to the implants. The interventions achieved satisfactory cosmetic and functional results. After one-year follow-up, the adjacent periodontal tissues remained without signs and/or symptoms of inflammation. The provisional crowns presented no mobility and fractures. During radiographic examination, a healthy bone tissue appearance was observed. The simplicity of mini-implant installation makes them a promising alternative for temporary prosthetic rehabilitation of patients undergoing growth and development. The technique provides positive aesthetic and functional results that may reflect on self-esteem and social inclusion of children and adolescents.

  18. Rothia prosthetic knee joint infection.

    Science.gov (United States)

    Trivedi, Manish N; Malhotra, Prashant

    2015-08-01

    Rothia species - Gram-positive pleomorphic bacteria that are part of the normal oral and respiratory flora - are commonly associated with dental cavities and periodontal disease although systemic infections have been described. We describe a 53-year-old female with rheumatoid arthritis complicated by prosthetic knee joint infection due to Rothia species, which was successfully treated by surgical removal of prosthesis and prolonged antimicrobial therapy. The issue of antibiotic prophylaxis before dental procedures among patients with prosthetic joint replacements is discussed. Copyright © 2012. Published by Elsevier B.V.

  19. Clinical Aspects of Combination of Aesthetic Fixed Prosthetic Appliances

    Directory of Open Access Journals (Sweden)

    Andrii Biben

    2017-10-01

    Full Text Available The objective of the research was to study the peculiarities of the combination of zirconia and ceramic occlusal surfaces when constructing aesthetic fixed prosthetic appliances. Materials and methods. The study included 70 patients with zirconia and ceramic occlusal surfaces of aesthetic fixed dental prostheses. Group I included 24 patients with a combination of zirconia and ceramic occlusal surfaces. Group II included 30 patients with a combination of ceramic occlusal surfaces. Group III included 16 patients with a combination of zirconia occlusal surfaces. All the patients were observed 12 and 24 months after prosthetic repair. Results. 12 and 24 months after prosthetic repair, the occlusal contact surface area was the largest in Group II (8.18±0.16 mm2 and 9.17±0.1 mm2, respectively. In Group I, where only one occlusive surface was made of zirconium dioxide, significantly reduced levels of abrasion were observed as compared to Group II – 8.07±0.21 mm2 and 8.65±0.23 mm2, respectively. 36 months after denture wearing, in Group III, the smallest contact surface area – 7.84±0.15 mm2as well as the lowest growth of the surface area was observed – 8.07±0.13 mm2. Conclusions. Dental prostheses with at least one ceramic occlusal surface exhibit a strong tendency to abrasion and, consequently, to an increase in the occlusal surface area resulting in an excessive load on prosthetic appliance. Moreover, functional and aesthetic values of prosthetic prosthesis sharply decrease. Therefore, we recommend to produce zirconia occlusal surface or at least to combine the same materials, as it will increase the longevity of prosthetic appliance.

  20. La ejecución provisional de las sentencias

    OpenAIRE

    Silva Álvarez,Óscar

    2008-01-01

    Dentro de la corriente reformista del proceso civil en Chile, un lugar importante debería estar ocupado por la figura de la ejecución provisional de las sentencias judiciales, como una manifestación del derecho a la tutela judicial efectiva y un instrumento para el acortamiento de los tiempos en el proceso. El presente artículo contiene un examen teórico a la figura de la ejecución provisional, y establece las reglas técnicas de su configuración legal. También analiza los aislados casos de ta...

  1. Performance characteristics of anthropomorphic prosthetic hands.

    Science.gov (United States)

    Belter, Joseph T; Dollar, Aaron M

    2011-01-01

    In this paper we set forth a review of performance characteristics for both common commercial prosthetics as well as anthropomorphic research devices. Based on these specifications as well as surveyed results from prosthetic users, ranges of hand attributes are evaluated and discussed. End user information is used to describe the performance requirements for prosthetic hands for clinical use. © 2011 IEEE

  2. Aerogel Use as a Skin Protective Liner In Space Suits and Prosthetic Limbs Project

    Science.gov (United States)

    Roberson, Luke Bennett

    2014-01-01

    Existing materials for prosthetic liners tend to be thick and airtight, causing perspiration to accumulate inside the liner and potentially causing infection and injury. The purpose of this project was to examine the suitability of aerogel for prosthetic liner applications for use in space suits and orthopedics. Three tests were performed on several types of aerogel to assess the properties of each material, and our initial findings demonstrated that these materrials would be excellent candidates for liner applications for prosthetics and space suits. The project is currently on hold until additional funding is obtained for application testing at the VH Hospitals in Tampa

  3. Developing a provisional and national renal disease registry for Iran

    Directory of Open Access Journals (Sweden)

    Sima Ajami

    2015-01-01

    Full Text Available Background: Disease registry is a database that includes information about people suffering a special kind of disease. The aim of this study was to first identify and compare the National Renal Disease Registry (NRDR characteristics in some countries with Iran; and second, develop a provisional and NRDR for Iran. Materials and Methods: Retrieval of data of the NRDR was performed by scholars responsible in related agencies, including the Ministry of Health and Medical Education, Renal Disease charity, and data registries in the United States, United Kingdom, Malaysia, and Iran. This research was applied, and the study was descriptive-comparative. The study population consisted of the NRDR in selected countries in which data were collected by forms that were designed according to the study objectives. Sources of data were researchers, articles, books, journals, databases, websites, related documents, and people who are active in this regard, and related agencies, including the Ministry of Health and Medical Education, and patient support charity. The researchers collected data for each country based on the study objectives and then put them in comparative tables. Data were analyzed by descriptive, comparative, and theoretical methods. Results: Most of the renal transplant teams report their own results as a single center experiences. America and Britain have a preeminent national registry of renal disease compared to other countries. Conclusion: Given that control, prevention, and treatment of chronic renal diseases incur high expenses and the disease is one of leading mortality factors in Iran and across the world and since national registry system for chronic renal diseases can provide better tools and strategies to manage and evaluate patients′ characteristics as well as risk factors which eventually leads to making better decisions.

  4. Prosthetic Hand Lifts Heavy Loads

    Science.gov (United States)

    Carden, James R.; Norton, William; Belcher, Jewell G.; Vest, Thomas W.

    1991-01-01

    Prosthetic hand designed to enable amputee to lift diverse heavy objects like rocks and logs. Has simple serrated end effector with no moving parts. Prosthesis held on forearm by system of flexible straps. Features include ruggedness, simplicity, and relatively low cost.

  5. Uncemented allograft-prosthetic composite reconstruction of the proximal femur

    Directory of Open Access Journals (Sweden)

    Li Min

    2014-01-01

    Full Text Available Background: Allograft-prosthetic composite can be divided into three groups names cemented, uncemented, and partially cemented. Previous studies have mainly reported outcomes in cemented and partially cemented allograft-prosthetic composites, but have rarely focused on the uncemented allograft-prosthetic composites. The objectives of our study were to describe a surgical technique for using proximal femoral uncemented allograft-prosthetic composite and to present the radiographic and clinical results. Materials and Methods: Twelve patients who underwent uncemented allograft-prosthetic composite reconstruction of the proximal femur after bone tumor resection were retrospectively evaluated at an average followup of 24.0 months. Clinical records and radiographs were evaluated. Results: In our series, union occurred in all the patients (100%; range 5-9 months. Until the most recent followup, there were no cases with infection, nonunion of the greater trochanter, junctional bone resorption, dislocation, allergic reaction, wear of acetabulum socket, recurrence, and metastasis. But there were three periprosthetic fractures which were fixed using cerclage wire during surgery. Five cases had bone resorption in and around the greater trochanter. The average Musculoskeletal Tumor Society (MSTS score and Harris hip score (HHS were 26.2 points (range 24-29 points and 80.6 points (range 66.2-92.7 points, respectively. Conclusions: These results showed that uncemented allograft-prosthetic composite could promote bone union through compression at the host-allograft junction and is a good choice for proximal femoral resection. Although this technology has its own merits, long term outcomes are yet not validated.

  6. Effect of provisional cements on shear bond strength of porcelain laminate veneers.

    Science.gov (United States)

    Altintas, Subutay Han; Tak, Onjen; Secilmis, Asli; Usumez, Aslihan

    2011-08-01

    The purpose of this study was to evaluate the effect of three provisional cements and two cleaning techniques on the final bond strength of porcelain laminate veneers. The occlusal third of the crowns of forty molar teeth were sectioned and embedded in autopolymerizing acrylic resin. Dentin surfaces were polished and specimens were randomly divided into four groups (n=10). Provisional restorations were fabricated and two provisional restorations were cemented onto each tooth. Restorations were fixed with one of three different provisional cements: eugenol-free provisional cement (Cavex), calcium hydroxide (Dycal), and light-cured provisional cement (Tempond Clear). Provisional restorations were removed with either a dental explorer and air-water spray, or a cleaning bur (Opticlean). In the control group, provisional restorations were not used on the surfaces of specimens. IPS Empress 2 ceramic discs were luted with a dual-cured resin cement (Panavia F). Shear bond strength was measured using a universal testing machine. Data were statistically analyzed by ANOVA, Tukey's HSD and Dunnett tests. Surfaces were examined by scanning electronic microscopy. Significant differences were found between the control group and both the light-cured provisional cement groups and the eugenol-free provisional cement-cleaning bur group (Pprovisional cement showed the lowest bond strength values. Selection of the provisional cement is an important factor in the ultimate bond strength of the final restoration. Calcium hydroxide provisional cement and cleaning with a dental explorer are advisable.

  7. PSYCHOACOUSTICS - A SELECTED BIBLIOGRAPHY. A PROVISIONAL BIBLIOGRAPHY.

    Science.gov (United States)

    DIMMICK, KENNETH

    THE 346 ENTRIES IN THIS BIBLIOGRAPHY COVER MATERIAL IN BOOKS, JOURNALS, AND MONOGRAPHS IN FIELDS RELATED TO THE SENSORY IMPAIRED, ESPECIALLY THE BLIND AND PARTIALLY SIGHTED. THE DATES RANGE FROM 1934 TO 1965. (MK)

  8. The effects of desensitizing resin, resin sealing, and provisional cement on the bond strength of dentin luted with self-adhesive and conventional resincements.

    Science.gov (United States)

    Sailer, Irena; Oendra, Andrea E Hernandez; Stawarczyk, Bogna; Hämmerle, Christoph H F

    2012-04-01

    Self-adhesive resin cements were designed to bond without any pretreatment of dentin. However, pretreatments such as the application of desensitizing resin or the resin sealing of dentin with priming/bonding solutions might influence the bonding quality of these self-adhesive resin cements. Little is known about the effect of dentin pretreatment on the bond quality of self-adhesive resin cements. This study evaluated whether dentin desensitizing or sealing methods influenced the shear bond strength of 1 self-adhesive and 2 conventional resin cements. One-hundred and eighty human molars were assigned to 5 different pretreatment groups: 1) freshly ground dentin, 2) glutaraldehyde/hydroxyethylmethacrylate (HEMA) desensitized dentin (Gluma), 3) contamination of desensitized dentin with provisional cement, 4) sealed dentin (dual bonding technique), and 5) contamination of sealed dentin with provisional cement. The shear bond strength of a self-adhesive resin cement (RelyX Unicem; RXU) and 2 conventional resin cements (Variolink II; VAR, Panavia 21; PAN) was assessed for each pretreatment group (n=12 per cement types). Two-way ANOVA and 1-way ANOVA together with the post hoc Tukey multiple comparison (α=.05) were performed. On freshly ground dentin, PAN exhibited the highest shear bond strength values (Pdentin (Pdentin increased the bond strength of RXU but had no significant effect on VAR or PAN. RXU exhibited the highest mean bond strength after the contamination of resin-sealed dentin by provisional cement. Glutaraldehyde/HEMA treatment and resin sealing of dentin have a beneficial effect on the shear bond strength of self-adhesive resin cement (RXU). Contamination of dentin with provisional cement has no influence on the bond strength of the self-adhesive resin cement (RXU) or VAR but lowered the bond strength of PAN. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  9. 21 CFR 872.3660 - Impression material.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3660 Impression material. (a) Identification... device is intended to provide models for study and for production of restorative prosthetic devices, such...

  10. Prosthetics & Orthotics Manufacturing Initiative (POMI)

    Science.gov (United States)

    2012-12-21

    have promise in allowing sockets to be adjusted after manufacture. The most likely configuration involves placing shape-memory foams , which are...demonstrated that the liquid carbon dioxide-based system could provide cooling through the thermal resistances of the viscoelastic liner now commonly worn...When a patient’s residual limb is covered by the prosthetic system, including a viscoelastic liner, the limb is robbed of all natural mechanisms

  11. Bar-holding prosthetic limb

    Science.gov (United States)

    Vest, Thomas W. (Inventor); Norton, William E. (Inventor); Belcher, Jewell G. (Inventor); Carden, James R. (Inventor)

    1992-01-01

    A prosthetic device for below-the-elbow amputees is disclosed. The device has a removable effector, which is attached to the end of an arm cuff. The effector is comprised of a pair of C-shaped members that are oriented so as to face each other. Working in concert, the C-shaped members are able to hold a bar such as a chainsaw handle. A flat spring is fitted around the C-shaped members to hold them together.

  12. Retentive force of O-ring attachment to use Immediate Provisional Implant (IPI)-retained overdenture.

    Science.gov (United States)

    Kobayashi, Mariko; Ohkubo, Chikahiro; Suzuki, Yasunori; Aoki, Takayuki; Sato, Jun-ichi; Hosoi, Toshio

    2005-12-01

    This study evaluated the retentive force of the O-ring attachment to an Immediate Provisional Implant (IPI)-retained overdenture. Two sizes of O-rings (#1, #2) were placed on the IPI abutment head. As the controls, soft relining material, silicone lining material, and the PMMA resin were used to connect the IPI abutment head. The retentive forces (n=5, N) obtained at a crosshead speed of 40 mm/min were analyzed by ANOVA/Tukey's HSD test (alpha=0.05). O-ring #1 showed the significantly greatest force among all materials tested (p0.05). Appropriate retention was obtained using the smaller O-ring#1 for the IPI-retained overdenture.

  13. Carbon based prosthetic devices

    Energy Technology Data Exchange (ETDEWEB)

    Devlin, D.J.; Carroll, D.W.; Barbero, R.S.; Archuleta, T. [Los Alamos National Lab., NM (US); Klawitter, J.J.; Ogilvie, W.; Strzepa, P. [Ascension Orthopedics (US); Cook, S.D. [Tulane Univ., New Orleans, LA (US). School of Medicine

    1998-12-31

    This is the final report of a one-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The project objective was to evaluate the use of carbon/carbon-fiber-reinforced composites for use in endoprosthetic devices. The application of these materials for the metacarpophalangeal (MP) joints of the hand was investigated. Issues concerning mechanical properties, bone fixation, biocompatibility, and wear are discussed. A system consisting of fiber reinforced materials with a pyrolytic carbon matrix and diamond-like, carbon-coated wear surfaces was developed. Processes were developed for the chemical vapor infiltration (CVI) of pyrolytic carbon into porous fiber preforms with the ability to tailor the outer porosity of the device to provide a surface for bone in-growth. A method for coating diamond-like carbon (DLC) on the articulating surface by plasma-assisted chemical vapor deposition (CVD) was developed. Preliminary results on mechanical properties of the composite system are discussed and initial biocompatibility studies were performed.

  14. Immediate implant placement and provisionalization with and without a connective tissue graft: an analysis of facial gingival tissue thickness.

    Science.gov (United States)

    Rungcharassaeng, Kitichai; Kan, Joseph Y K; Yoshino, Shuji; Morimoto, Taichiro; Zimmerman, Grenith

    2012-12-01

    Facial gingival tissue thickness (FGTT) is important for an esthetically pleasing anterior restoration since it determines the soft tissue's ability to conceal the underlying restorative material. The purpose of this study was to investigate the change in FGTT after immediate implant placement and provisionalization with and without a connective tissue graft. Patients with a failing maxillary anterior tooth planned for immediate implant placement and provisionalization with (CT group) or without (NCT group) a subepithelial connective tissue graft were included in this study. After tooth extraction, direct measurement of the FGTT was performed; subsequent measurements were performed at the time of definitive prosthesis placement. Data were analyzed using independent and paired t tests at a significance level of α = .05. There was no statistically significant difference in the mean FGTT at tooth extraction between the CT and NCT groups. At prosthesis delivery, the mean FGTT for the CT group was significantly greater than that of the NCT group. The mean FGTT of both groups at prosthesis delivery was significantly higher than that at tooth extraction. The mean change in FGTT in the CT group was also significantly greater than that in the NCT group. Immediate implant placement and provisionalization in conjunction with a connective tissue graft is more likely to result in sufficient peri-implant tissue thickness to conceal underlying implant restorative materials than when performed without a connective tissue graft.

  15. A new method for photodynamic disinfection of prosthetic constructions and impressions in prosthetic dentistry.

    Science.gov (United States)

    Vlahova, Angelina P; Kisov, Christo K; Popova, Elka V; Haydushka, Irina A; Mantareva, Vanya N

    2012-01-01

    Photodynamic therapy is a topical treatment of pathogens that involves the use of a photoactive dye (photosensitizer), which is non-toxic when not exposed to light and activated by light of a specific wavelength in the presence of oxygen. The highly cytotoxic oxygen species generated by the induced photophysical processes inactivate the pathogenic cells. The PURPOSE of this study was to present a new method we developed for photodynamic disinfection of prostheses and impressions in prosthetic dentistry and to assess its effectiveness in comparison with some conventional methods of disinfection. The method was developed on the basis of series of experimental studies (30 experiments for each type of disinfectant, 30 controls with no disinfection for each material, and 30 direct cultures of each test microorganism--MRSA, P. aeruginosa and C. albicans) using standard test specimens made of prosthesis plastic and impression materials. The new method of photodynamic disinfection with GaPc1 as photosensitizer was 100% efficient in C-silicones, A-silicones and polyethers, but not in alginates (40%). To plastics the photodynamic method shows the same efficiency as the conventional disinfectants of hypochlorite solutions and denture cleansing tablets (100% effect). The method of photodynamic disinfection we developed is a good therapeutic choice against orally transmitted diseases in prosthetic dentistry.

  16. Provisional Crown Dislodgement during Scuba Diving: A Case of Barotrauma

    OpenAIRE

    Meenal Nitin Gulve; Nitin Dilip Gulve

    2013-01-01

    Changes in ambient pressure, for example, during flying, diving, or hyperbaric oxygen therapy, can lead to barotrauma. Although it may seem that this issue was neglected in dental education and research in recent decades, familiarity with and understanding of these facts may be of importance for dental practitioners. We report the case of a patient who experienced barotrauma involving dislodgement of a provisional crown during scuba diving. Patients who are exposed to pressure changes as a pa...

  17. Immediately Loaded Intraorally Welded Complete-Arch Maxillary Provisional Prosthesis.

    Science.gov (United States)

    Albiero, Alberto Maria; Benato, Renato; Fincato, Andrea

    2015-01-01

    Guided implant surgery is not completely accurate when using computer-designed stereolithographic surgical guides. Complications are frequently reported when combining computer-guided flapless surgery with an immediately loaded prefabricated prosthesis. Achieving passive fit of a prefabricated prosthesis on the inserted implants the same day of the surgery can be difficult. The aim of this report is to show a new treatment approach to immediately loaded implants inserted with computer-guided surgery using an intraoral welded full-arch provisional prosthesis.

  18. Cognitive Control Signals for Neural Prosthetics

    National Research Council Canada - National Science Library

    S. Musallam; B. D. Corneil; B. Greger; H. Scherberger; R. A. Andersen

    2004-01-01

    Recent development of neural prosthetics for assisting paralyzed patients has focused on decoding intended hand trajectories from motor cortical neurons and using this signal to control external devices...

  19. Circuit For Control Of Electromechanical Prosthetic Hand

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1995-01-01

    Proposed circuit for control of electromechanical prosthetic hand derives electrical control signals from shoulder movements. Updated, electronic version of prosthesis, that includes two hooklike fingers actuated via cables from shoulder harness. Circuit built around favored shoulder harness, provides more dexterous movement, without incurring complexity of computer-controlled "bionic" or hydraulically actuated devices. Additional harness and potentiometer connected to similar control circuit mounted on other shoulder. Used to control stepping motor rotating hand about prosthetic wrist to one of number of angles consistent with number of digital outputs. Finger-control signals developed by circuit connected to first shoulder harness transmitted to prosthetic hand via sliprings at prosthetic wrist joint.

  20. PLANNING OF IMPLANTO‐PROSTHETIC STRUCTURES IN TOTAL EDENTATION ACCORDING TO BIOMECHANICAL CRITERIA

    OpenAIRE

    Vasile, N.; V. IBRIC‐CIORANU

    2013-01-01

    Scope of the study: Analysis of the biomechanical aspects of the implanto‐prosthetic structures for planning the treatment in cases of total edentation.Materials and method: The study was performed in the Clinics of Prosthetics and Oral Implantology, Military Emergency Hospital of Sibiu, on a group of mandibularly totally edentated patients. Planning of the implanto‐pros‐ thetic treatment had in view the peculiarities of total man‐ dibular edentation and observance of the biomechanical princi...

  1. Influence of the prosthetic arm length (palatal position) of zygomatic implants upon patient satisfaction

    Science.gov (United States)

    Pellicer-Chover, Hilario; Cervera-Ballester, Juan; Peñarrocha-Oltra, David; Bagán, Leticia; Peñarrocha-Diago, María

    2016-01-01

    Background To assess the influence of the prosthetic arm length (palatal position) of zygomatic implants upon patient comfort and stability, speech, functionality and overall satisfaction. Material and Methods A retrospective clinical study was made of patients subjected to rehabilitation of atrophic maxilla with complete maxillary implant-supported fixed prostheses involving a minimum of two zygomatic implants (one on each side) in conjunction with premaxillary implants, and with 12 months of follow-up after implant loading. Subjects used a VAS to score general satisfaction, comfort and stability, speech and functionality, and the results were analyzed in relation to the prosthetic arm length of the zygomatic implants 12 months after prosthetic delivery. Results Twenty-two patients participated in the study, receiving 22 prostheses anchored on 148 implants (44 were zygomatic and 94 were conventional implants). The mean right and left prosthetic arm length was 5.9±2.4 mm and 6.1±2.7 mm, respectively, with no statistically significant differences between them (p=0.576). The mean scores referred to comfort/retention, speech, functionality and overall satisfaction were high - no correlation being found between prosthetic arm length and patient satisfaction (p=0.815). Conclusions No relationship could be identified between prosthetic arm length (palatal position) and patient satisfaction. Key words:Zygomatic implants, patient satisfaction, zygomatic prosthesis, prosthetic arm length. PMID:26946206

  2. Evaluation of surface physical properties of acrylic resins for provisional prosthesis

    Directory of Open Access Journals (Sweden)

    Sérgio Paulo Hilgenberg

    2008-09-01

    Full Text Available Acrylic resins used for provisional prostheses should have satisfactory superficial characteristics in order to ensure gingival health and low bacterial attachment. The purpose of the present study was to evaluate the superficial roughness and contact angle after two types of polishing and the Vickers hardness of three acrylic resins (Duralay - G1, Dencrilay - G2, and Dencor - G3, all shade 66, indicated for provisional fixed prostheses. Five 20 x 3 ± 1 mm diameter discoid specimens were obtained for each group. One side of the specimens was subjected to standard polishing (pumice and whiting slurry, and the opposite side was polished with special tips. The mean roughness and contact angles of the materials were measured. The specimens were subjected to the Vickers microhardness test, which indicated that standard polishing produced a surface roughness equivalent to that of the special tips. The contact angles obtained with the standard polishing were equivalent to those observed in the special tips group. The microhardness of G1 and G3 resins showed statistical differences.

  3. Consumer Guide for Amputees: A Guide to Lower Limb Prosthetics

    Science.gov (United States)

    Consumer Guide for Amputees: A Guide to Lower Limb Prosthetics: Part I -- Prosthetic Design: Basic Concepts Volume 8 · ... wanted to have available a comprehensive explanation of limb prosthetics written in easily understood language for amputee consumers. ...

  4. Prosthetic choices for people with leg and arm amputations.

    Science.gov (United States)

    Kistenberg, Robert S

    2014-02-01

    New technology and materials have advanced prosthetic designs to enable people who rely on artificial limbs to achieve feats never dreamed before. However, the latest and the greatest technology is not appropriate for everyone. The aim of this article is to present contemporary options that are available for people who rely on artificial limbs to enhance their quality of life for mobility and independence. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Provisional implants for immediate restoration of partially edentulous jaws: a clinical study.

    Science.gov (United States)

    Krennmair, Gerald; Krainhöfner, Martin; Weinländer, Michael; Piehslinger, Eva

    2008-01-01

    The aim of this study was to evaluate the use of provisional implants, which can provide patients with provisional fixed partial dentures during the healing time of augmentation procedures and/or during the osseointegration period of definitive implants until delivery of the definitive prosthesis. Thirty-one patients were consecutively included in the study. Eighteen patients (group A, primary simultaneous group) were initially treated simultaneously with provisional and definitive implants and provided with 18 interim fixed partial dentures. Thirteen patients (group B) received provisional implants in a staggered procedure. In the first stage of group B patients (augmentation phase), provisional implants were placed to bridge the augmentation phase and for anchoring 13 interim fixed partial dentures. In the second stage (secondary simultaneous group), patients of group B received provisional implants to bridge the osseointegration phase for simultaneously placed definitive implants by further use of 13 interim fixed partial dentures. All patients were followed from provisional implant and definitive implant placement to delivery of the definitive prosthesis. Loss of provisional implants and interim fixed partial dentures was noted, and stability of provisional implants was evaluated using the Periotest device. The procedures of immediate rehabilitation with fixed partial dentures using provisional implants were subjectively rated by patients with regard to satisfaction, treatment period, and acceptance. In 31 patients, 44 provisional fixed partial dentures were supported by 98 provisional implants. No provisional implant loss in group A or group B-second stage was observed. Only 3 (3%) provisional implants were lost in group B-first stage during the augmentation phase. Incidence (90.8% versus 9.2%) and stability (Periotest values: 8.6 +/- 3.9 versus 4.8 +/- 2.7) of provisional implants differed significantly between maxilla and mandible (P fixed partial dentures

  6. Effect of Provisional Cements on Shear Bond Strength of Porcelain Laminate Veneers

    Science.gov (United States)

    Altintas, Subutay Han; Tak, Onjen; Secilmis, Asli; Usumez, Aslihan

    2011-01-01

    Objectives: The purpose of this study was to evaluate the effect of three provisional cements and two cleaning techniques on the final bond strength of porcelain laminate veneers. Methods: The occlusal third of the crowns of forty molar teeth were sectioned and embedded in autopolymerizing acrylic resin. Dentin surfaces were polished and specimens were randomly divided into four groups (n=10). Provisional restorations were fabricated and two provisional restorations were cemented onto each tooth. Restorations were fixed with one of three different provisional cements: eugenol-free provisional cement (Cavex), calcium hydroxide (Dycal), and light-cured provisional cement (Tempond Clear). Provisional restorations were removed with either a dental explorer and air-water spray, or a cleaning bur (Opticlean). In the control group, provisional restorations were not used on the surfaces of specimens. IPS Empress 2 ceramic discs were luted with a dual-cured resin cement (Panavia F). Shear bond strength was measured using a universal testing machine. Data were statistically analyzed by ANOVA, Tukey’s HSD and Dunnett tests. Surfaces were examined by scanning electronic microscopy. Results: Significant differences were found between the control group and both the light-cured provisional cement groups and the eugenol-free provisional cement-cleaning bur group (P<.05). Groups that had received light-cured provisional cement showed the lowest bond strength values. Conclusions: Selection of the provisional cement is an important factor in the ultimate bond strength of the final restoration. Calcium hydroxide provisional cement and cleaning with a dental explorer are advisable. PMID:21912495

  7. Rotationally actuated prosthetic helping hand

    Science.gov (United States)

    Norton, William E. (Inventor); Belcher, Jewell G., Jr. (Inventor); Carden, James R. (Inventor); West, Thomas W. (Inventor)

    1991-01-01

    A prosthetic device has been developed for below-the-elbow amputees. The device consists of a cuff, a stem, a housing, two hook-like fingers, an elastic band for holding the fingers together, and a brace. The fingers are pivotally mounted on a housing that is secured to the amputee's upper arm with the brace. The stem, which also contains a cam, is rotationally mounted within the housing and is secured to the cuff, which fits over the amputee's stump. By rotating the cammed stem between the fingers with the lower arm, the amputee can open and close the fingers.

  8. Redesign of a fixture mount to be used as an impression coping and a provisional abutment as well

    Directory of Open Access Journals (Sweden)

    Glenn Hsuan-Chen Chang

    2011-01-01

    Full Text Available Purpose: An integrated fixture mount/impression coping/ temporary abutment can provide many advantages for immediate loading of dental implants, such as simpler procedure, less chair time, cost reduction, and comfort for the patients. Materials and Methods: A newly designed dental implant fixture mount (DIFMA can be used as an impression coping for taking an immediate impression. An immediate load provisional prosthesis can then be fabricated shortly after implant placement to immediately load the implants. This fixture mount can also serve as a temporary abutment for immediate chair-side fabrication of provisional prosthesis. Two clinical cases are presented. Results: A clinical case utilizing the fixture mount abutment (DIFMA/implant assembly is presented. The precision of fitting between the impression copings and implants is secured with this system. The chair time for taking an immediate impression is greatly reduced. Less cost for the restoration is provided and patient comfort is delivered. Conclusions: More patient satisfaction can be conferred by employing the fixture mount in the process of immediate impression taking and as an immediate provisional abutment.

  9. The success rate of narrow body implants used for supporting immediate provisional restorations: a pilot feasibility study.

    Science.gov (United States)

    Wang, Hom-Lay; Okayasu, Kozue; Fu, Jia-Hui; Hamerink, Howard A; Layher, Mary G; Rudek, Ivan Elimar

    2012-12-01

    Implants were first designed to be used in the reconstruction of edentulous mandibles. However, with the technological advancement, enormous changes were made to improve the implant design and surface characteristics leading to the wide use of implants in the replacement of missing teeth. During the transition from an edentulous span to a fixed prosthesis, narrow body implants (NBIs) have been proposed to enhance patient comfort and function. Therefore, this study was aimed at investigating the survival and success rates of NBIs used for supporting immediately nonfunctional loaded provisional fixed partial denture (PFPD). Either 2.2- or 2.4-mm-diameter dental implants were placed transmucosally into the edentulous ridges of 10 partially edentulous patients. PFPD of self-cured bis-acryl composite material were made using either a vacuform template chairside or a relined prefabricated PFPD. Occlusal adjustments were made to ensure that there was no functional loading on the provisional restorations before they were secured onto the transitional implants. At 1 year, the implant success and survival rates were 38.7% and 93.5%, respectively, with a mean percentage of bone loss of 9.46% (0%-40%) and a mean bone loss of 1.19 mm (range: 0-3.5 mm). With a favorable implant survival rate, the use of NBIs to support provisional restorations seemed to be a feasible treatment option. In addition, there is merit for research on the long-term use of NBIs-supported final prostheses.

  10. Effect of water temperature on the fit of provisional crown margins during polymerization: An in vitro study

    Science.gov (United States)

    Ramkumar, Vivekanandan; Sangeetha, Arunachalam; Kumar, Vinaya

    2012-01-01

    Aim: To evaluate the effect of water temperature on the marginal fit of bis-acrylic composite provisional crown during resin polymerization. Materials and Methods: Precisely machined 10 brass master dies were designed to simulate molar teeth. Five brass dies were selected and precisely machined to simulate all ceramic crown preparation. An acrylic jaw replica was made in which brass dies were arranged equidistant from each other. A custom-made metallic tray was fabricated on the acrylic jaw replica to make polyvinyl siloxane impression matrix. Bis-acrylic composite resin provisional crowns were made using polyvinyl siloxane impression matrix. Provisional crowns were polymerized at room temperature (Group I direct technique, on dental stone cast; Group I indirect technique crowns) and at different water temperatures (Group II direct technique crowns). The vertical marginal gap between all the provisional crown margins and the finish line of brass dies was measured using a Research Stereomicroscope System. Results: The results were statistically analyzed using one-way analysis of variance (ANOVA) test and Newman–Keul's test. The results showed that crowns polymerized in 20°C and 30°C water had marginal gap approximately three times smaller than those polymerized in 30°C air, due to the reduced polymerization shrinkage. Conclusion: This study shows that crowns polymerized in 20°C and 30°C water had mean vertical marginal gap approximately three times smaller than those polymerized in 30°C air. It was approximately closer to that of crowns fabricated by indirect technique. Warmer water also supposedly hastens polymerization. PMID:23066294

  11. Effect of water temperature on the fit of provisional crown margins during polymerization: An in vitro study

    Directory of Open Access Journals (Sweden)

    Vivekanandan Ramkumar

    2012-01-01

    Full Text Available Aim: To evaluate the effect of water temperature on the marginal fit of bis-acrylic composite provisional crown during resin polymerization. Materials and Methods: Precisely machined 10 brass master dies were designed to simulate molar teeth. Five brass dies were selected and precisely machined to simulate all ceramic crown preparation. An acrylic jaw replica was made in which brass dies were arranged equidistant from each other. A custom-made metallic tray was fabricated on the acrylic jaw replica to make polyvinyl siloxane impression matrix. Bis-acrylic composite resin provisional crowns were made using polyvinyl siloxane impression matrix. Provisional crowns were polymerized at room temperature (Group I direct technique, on dental stone cast; Group I indirect technique crowns and at different water temperatures (Group II direct technique crowns. The vertical marginal gap between all the provisional crown margins and the finish line of brass dies was measured using a Research Stereomicroscope System. Results: The results were statistically analyzed using one-way analysis of variance (ANOVA test and Newman-Keul′s test. The results showed that crowns polymerized in 20°C and 30°C water had marginal gap approximately three times smaller than those polymerized in 30°C air, due to the reduced polymerization shrinkage. Conclusion: This study shows that crowns polymerized in 20°C and 30°C water had mean vertical marginal gap approximately three times smaller than those polymerized in 30°C air. It was approximately closer to that of crowns fabricated by indirect technique. Warmer water also supposedly hastens polymerization.

  12. Cochlear Implant Using Neural Prosthetics

    Science.gov (United States)

    Gupta, Shweta; Singh, Shashi kumar; Dubey, Pratik Kumar

    2012-10-01

    This research is based on neural prosthetic device. The oldest and most widely used of these electrical, and often computerized, devices is the cochlear implant, which has provided hearing to thousands of congenitally deaf people in this country. Recently, the use of the cochlear implant is expanding to the elderly, who frequently suffer major hearing loss. More cutting edge are artificial retinas, which are helping dozens of blind people see, and ìsmartî artificial arms and legs that amputees can maneuver by thoughts alone, and that feel more like real limbs.Research, which curiosity led to explore frog legs dancing during thunderstorms, a snail shapedorgan in the inner ear, and how various eye cells react to light, have fostered an understanding of how to ìtalkî to the nervous system. That understanding combined with the miniaturization of electronics and enhanced computer processing has enabled prosthetic devices that often can bridge the gap in nerve signaling that is caused by disease or injury.

  13. PLANNING OF IMPLANTO‐PROSTHETIC STRUCTURES IN TOTAL EDENTATION ACCORDING TO BIOMECHANICAL CRITERIA

    Directory of Open Access Journals (Sweden)

    N. VASILE

    2013-07-01

    Full Text Available Scope of the study: Analysis of the biomechanical aspects of the implanto‐prosthetic structures for planning the treatment in cases of total edentation.Materials and method: The study was performed in the Clinics of Prosthetics and Oral Implantology, Military Emergency Hospital of Sibiu, on a group of mandibularly totally edentated patients. Planning of the implanto‐pros‐ thetic treatment had in view the peculiarities of total man‐ dibular edentation and observance of the biomechanical principles. Selection of the type of occlusion restoration considered the presence of parafunctions and the nature of the antagonistic arch. Special attention was paid to the direction and intensity of the forces acting in the region of the future prosthetic work. When bruxism was manifested, its preimplantary removal was compulsory.Results and discussion: In fixed prosthetic restaurati‐ ons applied on implants, distribuition of forces obviously depend on the quality of osteo‐acceptance, as well, and also on the elasticity degree of the prosthetic work. In the case of mobilized prosthetic restorations supported on implants, rigidization of implants from the anterior region of the mandible may be obtained by means of a bar. In decreasing order of their elasticity, the materials employed are: acrylate, composites, noble and seminoble alloys, other metals, ceramics. Ceramics confers maximum stability to implants, yet without redeeming the forces. For amortizing the forces and for a progressive charging of the implants, it is recommended that the first (temporary prosthetic restorations should be made of either acrylate or compo‐ sites.Conclusions. Observance of the occlusological princi‐ ples in cases of occlusal reconstruction represents the determining element which assures the osteo‐acceptance of implants and the integrity of prosthetic restaurations.

  14. In vitro comparative evaluation of mechanical properties of temporary restorative materials used in fixed partial denture

    OpenAIRE

    D Saisadan; P Manimaran; P K Meenapriya

    2016-01-01

    Introduction: Materials used to fabricate provisional restorations can be classified as acrylics or resin composites. Provisional crows can be either prefabricated or custom made. Acrylics: These materials have been used to fabricate provisional restorations since the 1930s and usually available as powder and liquid. They are the most commonly used materials today for both single-unit and multiple-unit restorations. In general, their popularity is due to their low cost, acceptable esthetics, ...

  15. Effect of Provisional Cements on Shear Bond Strength of Porcelain Laminate Veneers

    OpenAIRE

    Altintas, Subutay Han; Tak, Onjen; Secilmis, Asli; Usumez, Aslihan

    2011-01-01

    Objectives: The purpose of this study was to evaluate the effect of three provisional cements and two cleaning techniques on the final bond strength of porcelain laminate veneers. Methods: The occlusal third of the crowns of forty molar teeth were sectioned and embedded in autopolymerizing acrylic resin. Dentin surfaces were polished and specimens were randomly divided into four groups (n=10). Provisional restorations were fabricated and two provisional restorations were cemented onto each to...

  16. Effect of Heat Treatment on the Physical Properties of Provisional Crowns during Polymerization: An in Vitro Study

    Directory of Open Access Journals (Sweden)

    May L. Mei

    2015-04-01

    Full Text Available This study concerned the effect of heat treatment during setting on the physical properties of four resin-based provisional restorative materials: Duralay (polymethyl methacrylate, Trim II (polyethyl methacrylate, Luxatemp (bis-acrylic composite, and Protemp 4 (bis-acrylic composite. Specimens were prepared at 23, 37, or 60 °C for evaluation of flexural strength, surface roughness, color change and marginal discrepancy. Flexural strength was determined by a three-point bending test. Surface profile was studied using atomic force microscopy. Color change was evaluated by comparing the color of the materials before and after placement in coffee. A travelling microscope helped prepare standardized crowns for assessment of marginal discrepancy. Flexural strength of all tested materials cured at 23 °C or 37 °C did not significantly change. The surface roughness and marginal discrepancy of the materials increased at 60 °C curing temperature. Marginal discrepancies, color stability, and other physical properties of materials cured at 23 °C or 37 °C did not significantly change. Flexural strength of certain provisional materials cured at 60 °C increased, but there was also an increase in surface roughness and marginal discrepancy.

  17. Provisional drivers' perceptions of the impact of displaying P plates.

    Science.gov (United States)

    Bates, Lyndel; Scott-Parker, Bridie; Darvell, Millie; Watson, Barry

    2017-11-17

    P plates (or decals) identify a driver's license status to other road users. They are a compulsory part of the graduated driver licensing system in Queensland, Australia, for drivers on a P1 (provisional 1) or P2 (provisional 2) license. This study explored the perceptions of young drivers regarding the display of P plates (decals) in Queensland, Australia. In this study, 226 young drivers with a provisional (intermediate/restricted) license completed a 30-min online survey between October 2013 and June 2014. t Tests were used to compare the opinions of people who displayed their plates nearly always with those who displayed them less frequently. Participants approved of the requirement to display P plates with 69% of those on a P1 license and 79% on a P2 license supporting the condition to display P1 (red) plates. Participants on a P1 license (62%) and a P2 license (68%) also approved the requirement to display P2 (green) plates. However, young drivers also perceived that the display of P plates (measured from 1 = never to 5 = nearly all the time) enabled newly licensed drivers to be targeted by police and other drivers (those who do not always display P plates: M = 3.72, SD = 0.94; those who nearly always display P plates: M = 3.43, SD = 1.09). The study findings suggest that participants who nearly always display their P plates are more likely to report that having to display their plates resulted in them driving more carefully.

  18. Effects of surface treatment and artificial aging on the shear bond strength of orthodontic brackets bonded to four different provisional restorations.

    Science.gov (United States)

    Al Jabbari, Youssef S; Al Taweel, Sara M; Al Rifaiy, Mohammed; Alqahtani, Mohammed Q; Koutsoukis, Theodoros; Zinelis, Spiros

    2014-07-01

    To evaluate the combined effects of material type, surface treatment, and thermocycling on the bond strength of orthodontic brackets to materials used for the fabrication of provisional crowns. Four materials were included in this study (ProTemp, Trim Plus, Trim II, and Superpont C+B). Sixty cylindrical specimens (1 × 3 cm) were prepared from each material and equally divided into three groups. The first group was ground with silica carbide paper, the second was polished with pumice, and the last group was sandblasted with 50-µm aluminum oxide particles. Stainless-steel maxillary central incisor brackets (Victory Series, 3M) were bonded to the provisional material specimens with Transbond XT light-cured composite resin, and half of the specimens from each group were thermocycled 500 times in 5°C and 55°C water baths. Then the brackets were debonded with shear testing, and the results were statistically analyzed by three-way analysis of variance and Tukey's multiple-comparison tests at α  =  0.05. Adhesive Remnant Index (ARI) was also identified. Before and after thermocycling, ProTemp materials showed the highest shear bond strength with orthodontic brackets (10.3 and 13.1 MPa, respectively). The statistical analysis indicated an interaction among the three independent variables (P < .05) and statistically significant differences in bond strength among provisional materials (P < .001), surface treatments (P < .001), and thermocycling (P < .05). According to the ARI, most groups demonstrated adhesive failure. The provisional material type, surface treatment, and artificial aging have a significant effect on bond strength. Sandblasting treatment exerts a beneficial effect on shear bond strength.

  19. Prosthetic abdominal wall hernia repair in emergency surgery: from polypropylene to biological meshes

    Directory of Open Access Journals (Sweden)

    Campanelli G

    2008-12-01

    Full Text Available Abstract The use of nonabsorbable prosthetic materials such as polypropylene, polyester, and ePTFE, have expanded and are now widely used in reparative surgery for abdominal wall hernias. There are still difficulties to find correct indication for prosthetic implant in emergency hernia surgery: as a matter of fact there is still a great debate if to use non-absorbable prostheses in potentially or truly infected operating fields [e.g. after intestinal resections]. All these problems can be avoided with the use of absorbable prosthetic materials such as those composed of lactic acid polymers or lactic and glycolic acid copolymers: however, the use of these absorbable prosthesis exposes the patient to a rapid and inevitable hernia recurrence. It is important to remember that prosthetic repair has been proven to have a significant less risk of recurrence than repair with direct sutures. Recently, new "biologic" prosthetic materials have been developed and proposed for the clinical use in infected fields. These materials can be called "remodeling" for the way by which they are replaced after their placement within the patient. The "remodeling" process is made possible through a process of incorporation, where a reproduction of a site-specific tissue similar to the original host tissue is created.

  20. 21 CFR 890.3420 - External limb prosthetic component.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External limb prosthetic component. 890.3420... External limb prosthetic component. (a) Identification. An external limb prosthetic component is a device... total prosthesis. Examples of external limb prosthetic components include the following: Ankle, foot...

  1. Outdoor weathering of facial prosthetic elastomers differing in Durometer hardness.

    Science.gov (United States)

    Willett, Emily S; Beatty, Mark W

    2015-03-01

    Facial prosthetic elastomers with wide ranges in hardness are available, yet material weatherability is unknown. The purpose of this study was to assess color, Durometer hardness, and tensile property changes after 3000 hours of outdoor weathering. Unpigmented elastomers with Durometer hardness 5, 30, 50, 70, and A-2186 were polymerized into dumbbells (ASTM D412) and disks, 34 mm in diameter by 6 mm thick. Materials were subjected to outdoor or time passage environments for 3000 hours. CIELab color (n=5), Durometer hardness (n=5), and tensile mechanical properties (n=10) were measured at 0 and 3000 hours, and group differences were assessed by material and weathering condition (ANOVA/Tukey, α=.05). Except for A-2186, the mean Durometer changes for all materials were 1 unit or less, with no significant differences observed between time passage and weathered groups (P≥.05). Three-thousand-hour tensile mechanical property results demonstrated nonsignificant differences between time passage and weathered materials but significantly changed properties from immediately tested materials (Phardness 5 and 30 and A-2186. With a few exceptions, outdoor weathering produced relatively small changes in color, Durometer hardness, or tensile properties compared with time passage. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. Development of prosthetic arm with pneumatic prosthetic hand and tendon-driven wrist.

    Science.gov (United States)

    Takeda, Hiroyuki; Tsujiuchi, Nobutaka; Koizumi, Takayuki; Kan, Hiroto; Hirano, Masanori; Nakamura, Yoichiro

    2009-01-01

    Recently, various prosthetic arms have been developed, but few are both attractive and functional. Considering human coexistence, prosthetic arms must be both safe and flexible. In this research, we developed a novel prosthetic arm with a five-fingered prosthetic hand using our original pneumatic actuators and a slender tendon-driven wrist using a wire drive and two small motors. Because the prosthetic hand's driving source is comprised of small pneumatic actuators, the prosthetic hand is safe when it makes contact with people; it can also operate flexibly. In addition, the arm has a tendon-driven wrist to expand its motion space and to perform many operations. First, we explain the pneumatic hand's drive mechanism and its tendon-driven wrist. Next, we identify the characteristics of the hand and the wrist and construct a control system for this arm and verify its control performance.

  3. Ergonomic workplace assessment in orthotic and prosthetic workshops.

    Science.gov (United States)

    Salmani Nodooshan, H; Koohi Booshehri, S; Daneshmandi, H; Choobineh, A R

    2016-10-17

    In Iranian orthotic and prosthetic workshops, the majority of activities are carried out by manpower and the tasks are labor-intensive. In these workshops, ergonomic aspects of working conditions are seldom considered. This study was conducted in orthotic and prosthetic workshops with the objectives of determination of prevalence rate of MSDs among employees and assessment of ergonomics working conditions. In this cross-sectional study, all employees (n = 42; 29 males and 13 females) in 11 active orthotic and prosthetic production centers of Shiraz city participated. Data were collected using Nordic Musculoskeletal disorders Questionnaire (NMQ) and observational technique by an ergonomics checklist for assessment of working conditions. The means (SD) of age and job tenure (years) in the study individuals were 37.26 (10.21) and 12.8 (9.39), respectively. The most prevalent MSD symptoms in the past 12 months were reported in the lower back (42.9%), shoulders (40.5%) and knees (40.5%). Working conditions assessment showed that the main ergonomic problems in the workshops studied originated from awkward working posture, improper workstation design, poorly designed hand tools and incorrect manual material handling. Any interventional program for working conditions improvement should, therefore, focus on these areas.

  4. A New F-18 Prosthetic Group via an Oxime Coupling

    Science.gov (United States)

    Carberry, Patrick; Lieberman, Brian P.; Ploessl, Karl; Choi, Seok R.; Haase, Danniebelle N.; Kung, Hank F.

    2011-01-01

    A novel fluorine-18 prosthetic ligand, 5-(1,3-dioxolan-2-yl)-2-(2-(2-(2- fluoroethoxy)ethoxy)ethoxy)pyridine [18F]2, has been synthesized. The prosthetic ligand is formed in high radiochemical yield (rcy = 71 ± 2 %, n = 3) with excellent radiochemical purity (rcp = 99 ± 1 %, n = 3) in a short reaction time (10 min). [18F]2 is a small, neutral, organic complex, easily synthesized in four steps from a readily available starting material. It can be anchored onto a target molecule containing an aminooxy functional group under acidic conditions by way of an oxime bond. We report herein two examples [18F]23 and [18F]24, potential imaging agents for β-amyloid plaques, which were labeled with this prosthetic group. This approach could be used for labeling proteins and peptides containing an aminooxy group. Biodistribution in male ICR mice for both oxime labeled complexes [18F]23 and [18F]24 were compared to that of the known β-amyloid plaque indicator, [18F]-AV-45, florbetapir 1. Oximes [18F]23 and [18F]24 are larger in size and therefore should reduce the blood-brain barrier (BBB) penetration. The brain uptake for oxime [18F]23 appeared to be reduced, but still retained some capability to cross the BBB. Oxime [18F]24 showed promising results after 2 min post injection (0.48 % dose/gram), however the uptake increased after 30 min post injection (0.92 % dose/gram) suggesting an in-vivo decomposition/metabolism of compound [18F]24. We have demonstrated a general protocol for the fluoride-18 labeling with a new prosthetic ligand [18F]2 that is tolerant towards several functional groups and is formed via chemoselective oxime coupling. PMID:21452846

  5. EEG Mind Controlled Smart Prosthetic Arm – A Comprehensive Study

    Directory of Open Access Journals (Sweden)

    Taha Beyrouthy

    2017-06-01

    Full Text Available Recently, the field of prosthetics has seen many accomplishments especially with the integration of technological advancements. In this paper, different arm types (robotic, surgical, bionic, prosthetic and static are analyzed in terms of resistance, usage, flexibility, cost and potential. Most of these techniques have some problems; they are extremely expensive, hard to install and maintain and may require surgery. Therefore, our work introduces the initial design of an EEG mind controlled smart prosthetic arm. The arm is controlled by the brain commands, obtained from an electroencephalography (EEG headset, and equipped with a network of smart sensors and actuators that give the patient intelligent feedback about the surrounding environment and the object in contact. This network provides the arm with normal hand functionality, smart reflexes and smooth movements. Various types of sensors are used including temperature, pressure, ultrasonic proximity sensors, accelerometers, potentiometers, strain gauges and gyroscopes. The arm is completely 3D printed built from various lightweight and high strength materials that can handle high impacts and fragile elements as well. Our project requires the use of nine servomotors installed at different places in the arm. Therefore, the static and dynamic modes of servomotors are analyzed. The total cost of the project is estimated to be relatively cheap compared to other previously built arms. Many scenarios are analyzed corresponding to the actions that the prosthetic arm can perform, and an algorithm is created to match these scenarios. Experimental results show that the proposed EEG Mind-controlled Arm is a promising alternative for current solutions that require invasive and expensive surgical procedures.

  6. Advanced upper limb prosthetic devices: implications for upper limb prosthetic rehabilitation.

    Science.gov (United States)

    Resnik, Linda; Meucci, Marissa R; Lieberman-Klinger, Shana; Fantini, Christopher; Kelty, Debra L; Disla, Roxanne; Sasson, Nicole

    2012-04-01

    The number of catastrophic injuries caused by improvised explosive devices in the Afghanistan and Iraq Wars has increased public, legislative, and research attention to upper limb amputation. The Department of Veterans Affairs (VA) has partnered with the Defense Advanced Research Projects Agency and DEKA Integrated Solutions to optimize the function of an advanced prosthetic arm system that will enable greater independence and function. In this special communication, we examine current practices in prosthetic rehabilitation including trends in adoption and use of prosthetic devices, financial considerations, and the role of rehabilitation team members in light of our experiences with a prototype advanced upper limb prosthesis during a VA study to optimize the device. We discuss key challenges in the adoption of advanced prosthetic technology and make recommendations for service provision and use of advanced upper limb prosthetics. Rates of prosthetic rejection are high among upper limb amputees. However, these rates may be reduced with sufficient training by a highly specialized, multidisciplinary team of clinicians, and a focus on patient education and empowerment throughout the rehabilitation process. There are significant challenges emerging that are unique to implementing the use of advanced upper limb prosthetic technology, and a lack of evidence to establish clinical guidelines regarding prosthetic prescription and treatment. Finally, we make recommendations for future research to aid in the identification of best practices and development of policy decisions regarding insurance coverage of prosthetic rehabilitation. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  7. FEM Analysis of Mandibular Prosthetic Overdenture Supported by Dental Implants: Evaluation of Different Retention Methods

    Directory of Open Access Journals (Sweden)

    M. Cicciù

    2015-01-01

    Full Text Available Prosthetic rehabilitation of total edentulous jaws patients is today a common technique that clinicians approach in their daily practice. The use of dental implants for replacing missing teeth is going to be a safe technique and the implant-prosthetic materials give the possibility of having long-term clinical success. Aim of this work is to evaluate the mechanical features of three different prosthetic retention systems. By applying engineering systems of investigations like FEM and von Mises analyses, how the dental implant material holds out against the masticatory strength during the chewing cycles has been investigated. Three common dental implant overdenture retention systems have been investigated. The ball attachment system, the locator system, and the common dental abutment have been processed by Ansys Workbench 15.0 and underwent FEM and von Mises investigations. The elastic features of the materials used in the study have been taken from recent literature data. Results revealed different response for both types of device, although locator system showed better results for all conditions of loading. The data of this virtual model show all the features of different prosthetic retention systems under the masticatory load. Clinicians should find the better prosthetic solution related to the patients clinical condition in order to obtain long-term results.

  8. FEM Analysis of Mandibular Prosthetic Overdenture Supported by Dental Implants: Evaluation of Different Retention Methods.

    Science.gov (United States)

    Cicciù, M; Cervino, G; Bramanti, E; Lauritano, F; Lo Gudice, G; Scappaticci, L; Rapparini, A; Guglielmino, E; Risitano, G

    2015-01-01

    Prosthetic rehabilitation of total edentulous jaws patients is today a common technique that clinicians approach in their daily practice. The use of dental implants for replacing missing teeth is going to be a safe technique and the implant-prosthetic materials give the possibility of having long-term clinical success. Aim of this work is to evaluate the mechanical features of three different prosthetic retention systems. By applying engineering systems of investigations like FEM and von Mises analyses, how the dental implant material holds out against the masticatory strength during the chewing cycles has been investigated. Three common dental implant overdenture retention systems have been investigated. The ball attachment system, the locator system, and the common dental abutment have been processed by Ansys Workbench 15.0 and underwent FEM and von Mises investigations. The elastic features of the materials used in the study have been taken from recent literature data. Results revealed different response for both types of device, although locator system showed better results for all conditions of loading. The data of this virtual model show all the features of different prosthetic retention systems under the masticatory load. Clinicians should find the better prosthetic solution related to the patients clinical condition in order to obtain long-term results.

  9. Lymphatic opacification in the prosthetic hip

    Energy Technology Data Exchange (ETDEWEB)

    Bloom, R.A.; Gheorghiu, D. (Hadassah Univ. Hospital, Jerusalem (Israel). Dept. of Radiology); Krausz, Y. (Hadassah Univ. Hospital, Jerusalem (Israel). Dept. of Nuclear Medicine)

    1991-01-01

    A retrospective analysis of 52 patients with hip pain following total hip replacement was made. Each of them was evaluated by plain radiographs, technetium 99m pyrophosphate scans, arthrography with plain film substraction technique, and culture of joint fluid. In 30 cases there was evidence of prosthetic loosening, and in 21 of these lymphangeal opacification during arthrography was seen. In 15 cases with lymphongeal opacification the daignosis of prosthetic loosening was subsequently confirmed by prosthetic revision. In none of the 22 cases in which no evidence of prosthetic loosening was seen was there lymphatic opacification. It is concluded that lymphatic opacification during arthrography for pain following total hip prosthesis is a valuable ancillary sign of loosening. (orig.).

  10. Computed Tomography of Prosthetic Heart Valves

    NARCIS (Netherlands)

    Habets, J.

    2012-01-01

    Prosthetic heart valve (PHV) dysfunction is an infrequent but potentially life-threatening disease with a heterogeneous clinical presentation. Patients with PHV dysfunction clinically can present with symptoms of congestive heart failure (dyspnea, fatigue, edema), fever, angina pectoris, dizziness

  11. Successful Thrombolysis of Aortic Prosthetic Valve Thrombosis ...

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    threatening. Standard surgical treatment using cardiopulmonary bypass carries high maternal and fetal complications. Here we report a case of an antenatal female in first trimester with aortic prosthetic valve thrombosis (PVT), who was successfully ...

  12. DME Prosthetics Orthotics, and Supplies Fee Schedule

    Data.gov (United States)

    U.S. Department of Health & Human Services — Durable Medical Equipment, Prosthetics-Orthotics, and Supplies Fee Schedule. The list contains the fee schedule amounts, floors, and ceilings for all procedure codes...

  13. Workplace exposure to nanoparticles and the application of provisional nanoreference values in times of uncertain risks

    NARCIS (Netherlands)

    van Broekhuizen, P; van Broekhuizen, F.; Cornelissen, R.; Reijnders, L.

    2012-01-01

    Nano reference values (NRVs) for occupational use of nanomaterials were tested as provisional substitute for Occupational Exposure Limits (OELs). NRVs can be used as provisional limit values until Health-Based OELs or derived no-effect levels (DNEL) become available. NRVs were defined for 8 h

  14. Provisional Admission Practices: Blending Access and Support to Facilitate Student Success

    Science.gov (United States)

    Nichols, Andrew Howard; Clinedinst, Melissa

    2013-01-01

    This report examines provisional admission as an initiative that can expand four-year college access and success for students from economically disadvantaged backgrounds. Provisional admission policies and programs enable students to enroll at an institution under specific conditions. Students are often required to meet certain academic…

  15. 76 FR 61042 - Modification of Regulations Regarding the Practice of Accepting Bonds During the Provisional...

    Science.gov (United States)

    2011-10-03

    ... Practice of Accepting Bonds During the Provisional Measures Period in Antidumping and Countervailing Duty... importers directly responsible for the payment of AD and CVD duties. DATES: This Final Rule is effective... practice of accepting bonds during the provisional measures period in AD and CVD investigations. See...

  16. Fabrication of a screw-retained fixed provisional prosthesis supported by dental implants.

    Science.gov (United States)

    Kökat, Ali Murat; Akça, Kivanç

    2004-03-01

    Screw-retained provisional implant-supported prostheses may have advantages over cement-retained prostheses in certain situations. This article describes a technique for fabrication of screw-retained provisional acrylic resin implant-supported prostheses from the modified metal components provided with the implant.

  17. Indirect implant-supported fixed provisional restoration in the esthetic zone: fabrication technique and treatment workflow.

    Science.gov (United States)

    Shor, Alexander; Schuler, Ralf; Goto, Yoshihiro

    2008-01-01

    Treatment objectives of an implant-supported fixed provisional restoration include shaping/preservation of the gingival soft tissue contour, functional and esthetic substitution of the missing dentition during postsurgical healing, and definitive prosthesis fabrication stages. Fixed provisional restoration can also serve as an esthetic and functional blueprint in the fabrication of the definitive restoration. Despite its common use and important indications, limited information is available on the various aspects of the provisional fabrication and treatment. This article presents a production technique and treatment workflow of a laboratory-fabricated, screw-retained fixed provisional restoration. Provisional restoration is fabricated using layering technique and internal stain characterization. The soft tissue profile of the working cast is modified according to the coronal contour of the diagnostic wax-up. Upon delivery, the provisional contour is reevaluated and modified as necessary. The developed emergence profile of the provisional restoration is transferred to the master cast via customized impression copings. Laboratory-fabricated implant-supported provisional restorations allow the esthetic and functional substitution of the missing dentition and the shaping of the soft tissue profile, and can act as a blueprint in the fabrication of definitive restorations.

  18. 78 FR 36571 - North American Datum of 1983 (NAD 83) Outer Continental Shelf (OCS) Provisional Official...

    Science.gov (United States)

    2013-06-18

    ... Official Protraction Diagrams in the Pacific Ocean, Hawaiian Islands Description/Date NF04-08 (Kaua'i... with this publication two NAD 83-based OCS Provisional OPDs that represent the Island of Oahu and... Title 43, Code of Federal Regulations, has created provisional versions of the basic record used for the...

  19. Surgical and Prosthetic Rehabilitation of Combination Syndrome

    Directory of Open Access Journals (Sweden)

    Paolo Carlino

    2014-01-01

    Full Text Available The aim of this report is to analyze the clinical symptoms, ethologic factors, and prosthetic rehabilitation in a case of Combination Syndrome (CS. The treatment of CS can be conventional or surgical, with or without the bone reconstruction of maxilla. The correct prosthetic treatment helps this kind of patients to restore the physiologic occlusion plane to allow a correct masticatory and aesthetic function. Management of this kind of patients can be a challenge for a dental practitioner.

  20. Advances in Retinal Prosthetic Research: A Systematic Review of Engineering and Clinical Characteristics of Current Prosthetic Initiatives.

    Science.gov (United States)

    Cheng, Derrick L; Greenberg, Paul B; Borton, David A

    2017-03-01

    To date, reviews of retinal prostheses have focused primarily on devices undergoing human trials in the Western Hemisphere and fail to capture significant advances in materials and engineering research in countries such as Japan and Korea, as well as projects in early stages of development. To address these gaps, this systematic review examines worldwide advances in retinal prosthetic research, evaluates engineering characteristics and clinical progress of contemporary device initiatives, and identifies potential directions for future research in the field of retinal prosthetics. A literature search using PubMed, Google Scholar, and IEEExplore was conducted following the PRISMA Guidelines for Systematic Review. Inclusion criteria were peer-reviewed papers demonstrating progress in human or animal trials and papers discussing the prosthetic engineering design. For each initiative, a description of the device, its engineering considerations, and recent clinical results were provided. Ten prosthetic initiatives met our inclusion criteria and were organized by stimulation location. Of these initiatives, four have recently completed human trials, three are undergoing multi- or single-center human trials, and three are undergoing preclinical animal testing. Only the Argus II (FDA 2013, CE 2011) has obtained FDA approval for use in the United States; the Alpha-IMS (CE 2013) has achieved the highest visual acuity using a Landolt-C test to date and is the only device presently undergoing a multicenter clinical trial. Several distinct approaches to retinal stimulation have been successful in eliciting visual precepts in animals and/or humans. However, many clinical needs are still not met and engineering challenges must be addressed before a retinal prosthesis with the capability to fully and safely restore functional vision can be realized.

  1. Early versus delayed, provisional eptifibatide in acute coronary syndromes.

    Science.gov (United States)

    Giugliano, Robert P; White, Jennifer A; Bode, Christoph; Armstrong, Paul W; Montalescot, Gilles; Lewis, Basil S; van 't Hof, Arnoud; Berdan, Lisa G; Lee, Kerry L; Strony, John T; Hildemann, Steven; Veltri, Enrico; Van de Werf, Frans; Braunwald, Eugene; Harrington, Robert A; Califf, Robert M; Newby, L Kristin

    2009-05-21

    Glycoprotein IIb/IIIa inhibitors are indicated in patients with acute coronary syndromes who are undergoing an invasive procedure. The optimal timing of the initiation of such therapy is unknown. We compared a strategy of early, routine administration of eptifibatide with delayed, provisional administration in 9492 patients who had acute coronary syndromes without ST-segment elevation and who were assigned to an invasive strategy. Patients were randomly assigned to receive either early eptifibatide (two boluses, each containing 180 microg per kilogram of body weight, administered 10 minutes apart, and a standard infusion > or = 12 hours before angiography) or a matching placebo infusion with provisional use of eptifibatide after angiography (delayed eptifibatide). The primary efficacy end point was a composite of death, myocardial infarction, recurrent ischemia requiring urgent revascularization, or the occurrence of a thrombotic complication during percutaneous coronary intervention that required bolus therapy opposite to the initial study-group assignment ("thrombotic bailout") at 96 hours. The key secondary end point was a composite of death or myocardial infarction within the first 30 days. Key safety end points were bleeding and the need for transfusion within the first 120 hours after randomization. The primary end point occurred in 9.3% of patients in the early-eptifibatide group and in 10.0% in the delayed-eptifibatide group (odds ratio, 0.92; 95% confidence interval [CI], 0.80 to 1.06; P=0.23). At 30 days, the rate of death or myocardial infarction was 11.2% in the early-eptifibatide group, as compared with 12.3% in the delayed-eptifibatide group (odds ratio, 0.89; 95% CI, 0.79 to 1.01; P=0.08). Patients in the early-eptifibatide group had significantly higher rates of bleeding and red-cell transfusion. There was no significant difference between the two groups in rates of severe bleeding or nonhemorrhagic serious adverse events. In patients who had acute

  2. VSRR - Provisional monthly and 12-month ending number of live births, deaths and infant deaths: United States

    Data.gov (United States)

    U.S. Department of Health & Human Services — https://www.cdc.gov/nchs/products/vsrr/provisional-tables.htm Monthly and 12 month-ending provisional counts of births, deaths and infant deaths are provided for the...

  3. Provisional Crown Dislodgement during Scuba Diving: A Case of Barotrauma

    Directory of Open Access Journals (Sweden)

    Meenal Nitin Gulve

    2013-01-01

    Full Text Available Changes in ambient pressure, for example, during flying, diving, or hyperbaric oxygen therapy, can lead to barotrauma. Although it may seem that this issue was neglected in dental education and research in recent decades, familiarity with and understanding of these facts may be of importance for dental practitioners. We report the case of a patient who experienced barotrauma involving dislodgement of a provisional crown during scuba diving. Patients who are exposed to pressure changes as a part of their jobs or hobbies and their dentists should know the causes of barotrauma. In addition, the clinician must be aware of the possible influence of pressure changes on the retention of dental components.

  4. Cetacean Swimming with Prosthetic Limbs

    Science.gov (United States)

    Bode-Oke, Ayodeji; Ren, Yan; Dong, Haibo; Fish, Frank

    2016-11-01

    During entanglement in fishing gear, dolphins can suffer abrasions and amputations of flukes and fins. As a result, if the dolphin survives the ordeal, swimming performance is altered. Current rehabilitation technques is the use of prosthesis to regain swimming ability. In this work, analyses are focused on two dolphins with locomotive impairment; Winter (currently living in Clearwater Marine Aquarium in Florida) and Fuji (lived in Okinawa Churaumi Aquarium in Japan). Fuji lost about 75% of its fluke surface to necrosis (death of cells) and Winter lost its tail due to amputation. Both dolphins are aided by prosthetic tails that mimic the shape of a real dolphin tail. Using 3D surface reconstruction techniques and a high fidelity Computational Fluid Dynamics (CFD) flow solver, we were able to elucidate the kinematics and hydrodynamics and fluke deformation of these swimmers to clarify the effectiveness of prostheses in helping the dolphins regain their swimming ability. Associated with the performance, we identified distinct features in the wake structures that can explain this gap in the performance compared to a healthy dolphin. This work was supported by ONR MURI Grant Number N00014-14-1-0533.

  5. Development and marketing of a prosthetic urinary control valve system

    Science.gov (United States)

    Tenney, J. B., Jr.; Rabinowitz, R.; Rogers, D. W.; Harrison, H. N.

    1983-01-01

    An implantable prosthetic for the control of urinary incontinence was developed and marketed. Three phases are presented: bench development studies, animal trials, and human clinical trials. This work was performed under the direction of a Research Team at Rochester General Hospital (RGH). Bench trials were completed on prototype hardware and provided early verification of the device's ability to withstand repeated cyclic testing. Configurational variants were evaluated and a preferred design concept was established. Silicone rubber (medical grade) was selected as the preferred material for the prosthesis.

  6. Percutaneous management of prosthetic valve thrombosis.

    Science.gov (United States)

    Hariram, Vuppaladadhiam

    2014-01-01

    Thrombosis of a prosthetic valve is a serious complication in patients with prosthetic heart valves. Thrombolysis is the initial choice of treatment. Patients who do not respond to thrombolysis are subjected to surgery which carries a high risk. We report a case series of 5 patients with prosthetic mitral valve thrombosis who did not respond to thrombolysis and were subjected to percutaneous manipulation of the prosthetic valves successfully and improved. Five patients who were diagnosed to have prosthetic mitral valve thrombosis and failed to respond to a minimum of 36 h of thrombolysis (persistent symptoms with increased gradients, abnormal findings on fluoroscopy),were subjected to percutaneous treatment after receiving proper consent. None of them had a visible thrombus on transthoracic echocardiogram. All patients underwent transseptal puncture following which a 6F JR4 guiding catheter was passed into the left atrium. The valve leaflets were repeatedly hit gently under fluoroscopic guidance till they regained their normal mobility. Mean age was 38.8 years. Average peak and mean gradients prior to the procedure were 38 and 25 and after the procedure were 12 and 6 mm of Hg respectively. All patients had successful recovery of valve motion on fluoroscopy with normalization of gradients and complete resolution of symptoms. None of the patients had any focal neurological deficits, embolic manifestations or bleeding complications. Percutaneous manipulation of prosthetic valves in selected patients with prosthetic valve thrombosis who do not respond to thrombolytic therapy is feasible and can be used as an alternative to surgery. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  7. Contribution of prosthetic treatment considerations for dental extractions of permanent teeth

    Science.gov (United States)

    Fernández-Barrera, Miguel Ángel; Casanova-Rosado, Juan Fernando; Mendoza-Rodríguez, Martha; Escoffié-Ramírez, Mauricio; Casanova-Rosado, Alejandro José; Navarrete-Hernández, José de Jesús; Maupomé, Gerardo

    2016-01-01

    Background. Tooth loss is an easily identifiable outcome that summarizes a complex suite of factors in an individual’s history of dental disease and its treatment by dental services over a lifetime. Assessment of overall tooth loss data is essential for epidemiologically evaluating the adequacy of dental care provided at a systems level, as well as for placing in context tooth loss for non-disease causes. For example, when derived from prosthetic treatment planning, the latter may unfortunately lead to some teeth being extracted (pulled) for the sake of better comprehensive clinical results. The objective of the present manuscript was to identify the contribution to overall tooth loss, by extraction of permanent teeth because of prosthetic treatment reasons. Material and Methods. A cross-sectional study included sex, age, total number of extractions performed by subject, sextant (anterior vs. posterior), group of teeth (incisors, canines, premolars and molars), upper or lower arch, and the main reason underlying extraction (extraction for any reason vs. prosthetic treatment), in patients 18 years of age and older seeking care at a dental school clinic in Mexico. A multivariate logistic regression model was generated. Results. A total of 749 teeth were extracted in 331 patients; 161 teeth (21.5% of total) were extracted for explicit prosthetic treatment indications. As age increased, the likelihood of having an extraction for prosthetic reasons increased 3% (OR = 1.03, p extractions increased, the risk of having an extraction for prosthetic reasons decreased (OR = 0.94, p extractions of permanent teeth were performed for prosthetic reasons in this dental school clinical environment; age, sex, type of tooth, and the total number of extractions moderated such pattern. PMID:27441103

  8. Reconsidering evidence-based practice in prosthetic rehabilitation: a shared enterprise.

    Science.gov (United States)

    van Twillert, Sacha; Geertzen, Jan; Hemminga, Titia; Postema, Klaas; Lettinga, Ant

    2013-06-01

    A divide is experienced between producers and users of evidence in prosthetic rehabilitation. To discuss the complexity inherent in establishing evidence-based practice in a prosthetic rehabilitation team illustrated by the case of prosthetic prescription for elderly dysvascular transfemoral amputee patients. A qualitative research design was used, in which data from multiple sources was triangulated to extract themes for discussion. This discussion paper draws on empirical material gathered by individual and focus-group interviews with members of a prosthetic rehabilitation team, information on technological advancements presented on websites of orthopaedic industry, guidelines and literature study. A prosthetic rehabilitation team needs to deal with lack of evidence, contradictory results, various classification systems, diverging interests of different stakeholders and many modifying factors, and all of this in a continuous technological changing environment. Integrating research designs with different strengths but not sharing the same biases may help researchers to deal with the multimorbidity and multifaceted disability of the target group. Articulating clinical knowledge, patients' needs and values in a systematic way provides depth, detail, nuance and context for evidence-based practice issues in prosthetic rehabilitation. Reconsidering the relationship between evidence, technology and rehabilitation practice is an imperative shared enterprise for clinicians and researchers. Scientific, clinical and patient-related knowledge are seen as important knowledge practices that should inform and strengthen each other. This discussion paper puts the academic clinical debate on evidence-based practice in prosthetics and orthotics in another light. By demonstrating the complexities surrounding evidence-based practice, it is argued and illustrated how both researchers and clinicians can contribute to optimal patient care in which evidence, technology and

  9. A "Jail Escape Technique" (JET) for distal side branch wiring during provisional stenting: Feasibility and first-in-man study.

    Science.gov (United States)

    Xiao, Han; Chen, Shengda; Wang, Guixue; Du, Ruolin; Song, Yaoming; Jin, Jun; Huang, Lan; Jabbour, Richard; Azzalini, Lorenzo; Zhao, Xiaohui

    2017-12-01

    To evaluate the feasibility of a novel technique for achieving distal SB access and improve strut apposition during provisional stenting. While distal rewiring and stent expansion toward the side branch (SB) are associated with better results during provisional stenting of coronary artery bifurcation lesions, these techniques are technically challenging and often leave unopposed struts near the carina. The "Jail Escape Technique" (JET) is performed by passing the proximal tip of the SB wire between the main vessel (MV) stent struts and balloon before implantation, allowing the MV stent to push the SB wire against the distal part of the carina. The MV stent can then be deployed without jailing the SB wire. Distal SB access and strut distribution at the carina were tested in phantom and swine models. Stent distortion, dislodgement forces, and material damage were evaluated with tensile testing. Human feasibility was then tested on 32 patients. Preclinical testing demonstrated that the SB wire was located at the most distal part of the carina and no strut malapposition at the carina was present after balloon inflation. Stent distortion, dislodgement forces, or material damage were not affected. JET was successfully performed in 30 of 32 patients. No major adverse cardiovascular events occurred in any patient at 6-month follow-up. The "JET" enables distal SB access and eliminates strut malapposition at the carina. Further studies with larger numbers of patients are needed to further investigate this technique. © 2017, Wiley Periodicals, Inc.

  10. Prosthetic fitting after rotationplasty of the knee.

    Science.gov (United States)

    So, Noel F; Andrews, Karen L; Anderson, Kimberly; Gozola, Michael A; Shives, Thomas C; Rose, Peter S; Shaughnessy, William J; Sim, Franklin H

    2014-04-01

    The objectives of this study were to describe the authors' experience with the timeline for prosthetic fitting after rotationplasty of the knee and to determine factors that may be associated with earlier prosthetic fitting. The authors conducted a retrospective observational study of 12 patients who underwent rotationplasty of the knee and received prosthetic care at this institution. All patients had oncologic causes for surgery. The median age at amputation was 10 yrs. The overall survival rate was 92%. Five patients received a preliminary bypass prosthesis. All 12 patients were successfully fitted with a definitive prosthesis. Three patients were fitted within 90 days; two of these three patients did not require chemotherapy. The median time for definitive prosthetic fitting in the ten patients requiring chemotherapy was 230.5 days (range, 85-425 days). Nine patients had documentation supporting a return to sport/premorbid physical recreational activities. In the authors' experience, chemotherapy was associated with delayed definitive prosthetic fitting. Typically, the patients who required rotationplasty for cancer completed fitting with a definitive prosthesis in 6 mos. The findings of this study validate previous reports and confirm that most rotationplasty patients have excellent outcomes with return to premorbid physical activities.

  11. [Clinical evaluation of "All-on-Four" provisional prostheses reinforced with carbon fibers].

    Science.gov (United States)

    Li, Bei-bei; Lin, Ye; Cui, Hong-yan; Hao, Qiang; Xu, Jia-bin; Di, Ping

    2016-02-18

    To assess the clinical effects of carbon fiber reinforcement on the "All-on-Four" provisional prostheses. Provisional prostheses were divided into control group and carbon fiber reinforcing group according to whether carbon fiber reinforcement was used in the provisional prostheses base resin. In our study, a total of 60 patients (32 males and 28 females) with 71 provisional prostheses(28 maxilla and 43 mandible)were enrolled between April 2008 and December 2012 for control group; a total of 23 patients (13 males and 10 females) with 28 provisional prostheses (9 maxillas and 19 mandibles) were enrolled between January 2013 and March 2014 for carbon fiber reinforcing group. The information of provisional prostheses in the patients was recorded according to preoperative examination. We used the date of definitive prosthesis restoration as the cut-off point, observing whether fracture occurred on the provisional prostheses in the two groups. Additionally we observed whether fiber exposure occurred on the tissue surface of the provisional prostheses and caused mucosal irritation. The interface between the denture base resin and the fibers was examined using scanning electron microscopy (SEM). The age [(57.3 ± 10.1) years vs.(55.1 ± 11.4) years], gender (32 males and 28 females vs. 13 males and 10 females), maxilla and mandible distributions (28 maxillas and 43 mandibles vs. 9 maxillas and 19 mandibles), the number of extraction jaws (46 vs. 23), the average using time [(7.8 ± 1.3) months vs. (7.5 ± 1.1) months], and the opposing dentition distributions of provisional prostheses of the patients showed no significant differences between the control and reinforcing groups. There were 21(29.6%) fractures that occurred on the 71 provisional prostheses in the control group; there was no fracture that occurred on the 28 provisional prosthesesin the carbon fiber reinforcing group. The fracture rate of the carbon fiber reinforcing group was significantly lower than that of

  12. Bruxism and prosthetic treatment: a critical review.

    Science.gov (United States)

    Johansson, Anders; Omar, Ridwaan; Carlsson, Gunnar E

    2011-07-01

    Based on the findings from available research on bruxism and prosthetic treatment published in the dental literature, an attempt was made to draw conclusions about the existence of a possible relationship between the two, and its clinical relevance. MEDLINE/PubMed searches were conducted using the terms 'bruxism' and 'prosthetic treatment', as well as combinations of these and related terms. The few studies judged to be relevant were critically reviewed, in addition to papers found during an additional manual search of reference lists within selected articles. Bruxism is a common parafunctional habit, occurring both during sleep and wakefulness. Usually it causes few serious effects, but can do so in some patients. The etiology is multifactorial. There is no known treatment to stop bruxism, including prosthetic treatment. The role of bruxism in the process of tooth wear is unclear, but it is not considered a major cause. As informed by the present critical review, the relationship between bruxism and prosthetic treatment is one that relates mainly to the effect of the former on the latter. Bruxism may be included among the risk factors, and is associated with increased mechanical and/or technical complications in prosthodontic rehabilitation, although it seems not to affect implant survival. When prosthetic intervention is indicated in a patient with bruxism, efforts should be made to reduce the effects of likely heavy occlusal loading on all the components that contribute to prosthetic structural integrity. Failure to do so may indicate earlier failure than is the norm. Copyright © 2011 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  13. The cleft sternum: a possible role for pliable prosthetic reconstruction.

    Science.gov (United States)

    Kaddoura, Imad L; Obeid, Mounir Y

    2014-01-01

    Faced with our intraoperative inability to primarily close a very wide isolated cleft sternum of a pediatric patient without causing cardiovascular decompensation, we describe our use of a synthetic material for partial approximation allowing muscular coverage. We report an infant who was born with an isolated large complete sternal cleft where a trial of primary surgical repair had to be abandoned because of cardiovascular compromise. A similar difficulty was encountered in approximating the origins of both pectoralis major muscle flaps at the midline. Thus, a pliable synthetic patch was helpful in partially obliterating the widened sternal defect allowing successful muscular coverage. Closure of a wide congenital sternal cleft using a synthetic material that partially obliterated an otherwise widely separated cleft sternum which was neither amenable for primary repair, nor by bilateral pectoralis major advancement alone, was possible. Strong prosthetic pliable material may offer a simple and useful procedure allowing obliteration of the widely separated cleft sternum not amenable for primary repair.

  14. Optimising the prescription of prosthetic technologies (opptec): Outcome measures for evidence based prosthetic practice and use

    LENUS (Irish Health Repository)

    Ryall, Dr Nicola

    2010-01-01

    This study provided a forum for patients and service providers to voice their opinions in what they believe to be the important predictors and outcomes involved in successful rehabilitation following limb loss. To develop a consensus on the most important outcomes and factors to address for both the lower limb and upper limb prosthetic prescription process, the above data relating to lower limb and upper prosthetics were subsequently used in the next phase of the research involving two Delphi surveys of 23 and 53 experts within the lower limb and upper limb amputation and prosthetic field respectively, including users, service providers and researchers.\\r\

  15. Mesofluidic controlled robotic or prosthetic finger

    Science.gov (United States)

    Lind, Randall F; Jansen, John F; Love, Lonnie J

    2013-11-19

    A mesofluidic powered robotic and/or prosthetic finger joint includes a first finger section having at least one mesofluidic actuator in fluid communication with a first actuator, a second mesofluidic actuator in fluid communication with a second actuator and a second prosthetic finger section pivotally connected to the first finger section by a joint pivot, wherein the first actuator pivotally cooperates with the second finger to provide a first mechanical advantage relative to the joint point and wherein the second actuator pivotally cooperates with the second finger section to provide a second mechanical advantage relative to the joint point.

  16. [Prosthetic rehabilitation: needs in Senegalese dental offices].

    Science.gov (United States)

    Mbodj, E B; Diouf, M; Faye, D; Ndiaye, A; Seck, M T; Ndiaye, C; Diallo, P D

    2011-12-01

    Knowledge of dental prosthetic needs will develop strategies for prevention and treatment through a package of individual, community and professional policies. The aim of this study was to evaluate prosthetic needs in Senegalese dental offices. The survey was conducted among people aged 15 years and more attending Senegalese dental clinics. The mean number of missing teeth was 4.4. Only 55.3% of the sample expressed the need for dentures and 81.8% had a diagnosed need for prosthesis. A statistically significant difference was noticed between the needs diagnosed and the expressed needs (p dental offices.

  17. VSRR - State and National Provisional Counts for Live Births, Deaths, and Infant Deaths

    Data.gov (United States)

    U.S. Department of Health & Human Services — NOTES: Figures include all revisions received from the states and, therefore, may differ from those previously published. Data are provisional and are subject to...

  18. Using a fixed provisional prosthesis during post-extraction healing and implant placement.

    Science.gov (United States)

    McArdle, Barry F

    2006-03-01

    Most dental patients insist on the use of provisional prostheses throughout healing and osseointegration when replacing extracted teeth with implants in esthetically sensitive areas. Removable appliances of some kind are normally used for this purpose, but patients often consider them to be too cumbersome. This can lead to decreased case acceptance and compliance with the use of the provisional restoration, which can compromise the final result of treatment. Custom fixed solutions to this problem exist, but they tend to be more complicated, less practical, and more expensive than other options now available. The Monodont bridge, a new system of prefabricated components for the creation of provisional fixed partial dentures, can be more esthetic, more retentive, more functional, more cost-effective, and more universally applicable than any other available techniques. This can raise patient tolerance of provisional prostheses and thus increase case acceptance, while fostering a more predictable esthetic result with regard to soft tissue contours and emergence profile.

  19. A provisional gene regulatory atlas for mouse heart development.

    Science.gov (United States)

    Chen, Hailin; VanBuren, Vincent

    2014-01-01

    Congenital Heart Disease (CHD) is one of the most common birth defects. Elucidating the molecular mechanisms underlying normal cardiac development is an important step towards early identification of abnormalities during the developmental program and towards the creation of early intervention strategies. We developed a novel computational strategy for leveraging high-content data sets, including a large selection of microarray data associated with mouse cardiac development, mouse genome sequence, ChIP-seq data of selected mouse transcription factors and Y2H data of mouse protein-protein interactions, to infer the active transcriptional regulatory network of mouse cardiac development. We identified phase-specific expression activity for 765 overlapping gene co-expression modules that were defined for obtained cardiac lineage microarray data. For each co-expression module, we identified the phase of cardiac development where gene expression for that module was higher than other phases. Co-expression modules were found to be consistent with biological pathway knowledge in Wikipathways, and met expectations for enrichment of pathways involved in heart lineage development. Over 359,000 transcription factor-target relationships were inferred by analyzing the promoter sequences within each gene module for overrepresentation against the JASPAR database of Transcription Factor Binding Site (TFBS) motifs. The provisional regulatory network will provide a framework of studying the genetic basis of CHD.

  20. A provisional gene regulatory atlas for mouse heart development.

    Directory of Open Access Journals (Sweden)

    Hailin Chen

    Full Text Available Congenital Heart Disease (CHD is one of the most common birth defects. Elucidating the molecular mechanisms underlying normal cardiac development is an important step towards early identification of abnormalities during the developmental program and towards the creation of early intervention strategies. We developed a novel computational strategy for leveraging high-content data sets, including a large selection of microarray data associated with mouse cardiac development, mouse genome sequence, ChIP-seq data of selected mouse transcription factors and Y2H data of mouse protein-protein interactions, to infer the active transcriptional regulatory network of mouse cardiac development. We identified phase-specific expression activity for 765 overlapping gene co-expression modules that were defined for obtained cardiac lineage microarray data. For each co-expression module, we identified the phase of cardiac development where gene expression for that module was higher than other phases. Co-expression modules were found to be consistent with biological pathway knowledge in Wikipathways, and met expectations for enrichment of pathways involved in heart lineage development. Over 359,000 transcription factor-target relationships were inferred by analyzing the promoter sequences within each gene module for overrepresentation against the JASPAR database of Transcription Factor Binding Site (TFBS motifs. The provisional regulatory network will provide a framework of studying the genetic basis of CHD.

  1. 21 CFR 895.101 - Prosthetic hair fibers.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prosthetic hair fibers. 895.101 Section 895.101...) MEDICAL DEVICES BANNED DEVICES Listing of Banned Devices § 895.101 Prosthetic hair fibers. Prosthetic hair fibers are devices intended for implantation into the human scalp to simulate natural hair or conceal...

  2. Comparative roll-over analysis of prosthetic feet

    NARCIS (Netherlands)

    Curtze, Carolin; Hof, At L.; van Keeken, Helco G.; Halbertsma, Jan P. K.; Postema, Klaas; Otten, Bert

    2009-01-01

    A prosthetic foot is a key element of a prosthetic leg, literally forming the basis for a stable and efficient amputee gait. We determined the roll-over characteristics of a broad range of prosthetic feet and examined the effect of a variety of shoes on these characteristics. The body weight of a

  3. Evaluation of surface physical properties of acrylic resins for provisional prosthesis

    OpenAIRE

    Sérgio Paulo Hilgenberg; Emigdio Enrique Orellana-Jimenez; Wilmer Fabian Sepúlveda-Navarro; Beatriz Elena Arana-Correa; Dario César Teixeira Alves; Nara Hellen Campanha

    2008-01-01

    Acrylic resins used for provisional prostheses should have satisfactory superficial characteristics in order to ensure gingival health and low bacterial attachment. The purpose of the present study was to evaluate the superficial roughness and contact angle after two types of polishing and the Vickers hardness of three acrylic resins (Duralay - G1, Dencrilay - G2, and Dencor - G3), all shade 66, indicated for provisional fixed prostheses. Five 20 x 3 ± 1 mm diameter discoid specimens were obt...

  4. In Vitro Fit and Cementation Resistance of Provisional Crowns for Single Implant-Supported Restorations

    OpenAIRE

    Moris,Izabela Cristina Maurício; Oliveira,Juliana Elias de; Faria,Adriana Cláudia Lapria; Ribeiro,Ricardo Faria; Rodrigues,Renata Cristina Silveira

    2015-01-01

    Abstract: This study aimed to verify marginal fit and the effect of cement film thickness standardization on retention of provisional crowns made with prefabricated acrylic cylinders on abutments, using two temporary luting agents subjected or not to mechanical cycling. Provisional crowns were made from bis-acryl (Luxatemp Fluorescence) or methyl methacrylate (Duralay) resins on acrylic cylinders and marginal fit and cement film thickness were evaluated. For retention evaluation, crowns were ...

  5. Dynamic Facial Prosthetics for Sufferers of Facial Paralysis

    Directory of Open Access Journals (Sweden)

    Fergal Coulter

    2011-10-01

    Full Text Available BackgroundThis paper discusses the various methods and the materialsfor the fabrication of active artificial facial muscles. Theprimary use for these will be the reanimation of paralysedor atrophied muscles in sufferers of non-recoverableunilateral facial paralysis.MethodThe prosthetic solution described in this paper is based onsensing muscle motion of the contralateral healthy musclesand replicating that motion across a patient’s paralysed sideof the face, via solid state and thin film actuators. Thedevelopment of this facial prosthetic device focused onrecreating a varying intensity smile, with emphasis ontiming, displacement and the appearance of the wrinklesand folds that commonly appear around the nose and eyesduring the expression.An animatronic face was constructed with actuations beingmade to a silicone representation musculature, usingmultiple shape-memory alloy cascades. Alongside theartificial muscle physical prototype, a facial expressionrecognition software system was constructed. This formsthe basis of an automated calibration and reconfigurationsystem for the artificial muscles following implantation, soas to suit the implantee’s unique physiognomy.ResultsAn animatronic model face with silicone musculature wasdesigned and built to evaluate the performance of ShapeMemory Alloy artificial muscles, their power controlcircuitry and software control systems. A dual facial motionsensing system was designed to allow real time control overmodel – a piezoresistive flex sensor to measure physicalmotion, and a computer vision system to evaluate real toartificial muscle performance.Analysis of various facial expressions in real subjects wasmade, which give useful data upon which to base thesystems parameter limits.ConclusionThe system performed well, and the various strengths andshortcomings of the materials and methods are reviewedand considered for the next research phase, when newpolymer based artificial muscles are constructed

  6. The effect of dentin desensitizers on thermal changes in the pulp chamber during fabrication of provisional restorations.

    Science.gov (United States)

    Usumez, A; Ozturk, A N; Aykent, F

    2004-06-01

    The purpose of this study was to evaluate the effect of two dentin desensitizers on the pulp chamber temperature increase during fabrication of provisional restorations by a direct method. Sixty intact extracted mandibular third molars were prepared for a metal-ceramic complete crown. Then the teeth were randomly divided into three groups of 20 each. Group 1, no dentin desensitizer was used as the control group; group 2, a resin-based dentin desensitizer was selected; and group 3, the prepared teeth surfaces were coated with polyurethane cyanoacrylate adhesive. Each of the three groups was further divided into two polymerizing systems (autopolymerizing and a photopolymerizing) of 10 each. After insertion of the resin-filled matrix, the temperature change in the pulpal chamber was recorded with thermocouple connected to a data logger. anova indicated no significant differences for all combinations of desensitizing agents and curing methods (P > 0.05). When light cured composite or chemical curing acrylics were used to make temporary crowns, the presence of desensitizing agent did not reduce the temperature transmitted from the provisional material; the residual temperature rise transmitted was of such a magnitude as to cause concern regarding possible thermal injury to pulp.

  7. Clinical evaluation of a visible light-cured indirect composite for long-term provisionalization.

    Science.gov (United States)

    Ewoldsen, Nels; Sundar, Veeraraghavan; Bennett, William; Kanya, Kevin; Magyar, Karl

    2008-01-01

    To clinically evaluate a visible light-cured (VLC) resin composite system for long-term provisional and esthetic diagnostic restorations, fabricated using indirect techniques. One-hundred and nine teeth were restored in 31 patients. Preoperational impressions were used to create VLC resin composite restorations (Radica) using indirect techniques. Restorations were relined as necessary and placed using various provisional cements at a follow-up appointment, subsequent to preparation of the teeth. Both fabricating laboratory technicians and placing dentists rated the restorations for acceptability in esthetics, marginal fit, occlusion, and functionality in various stages of provisionalization. All restorations (100%) were rated acceptable for esthetics prior to relining. After relining, a majority (93-100%) of restorations were rated acceptable in esthetic and functional criteria. At the placement of the permanent restoration, a majority (96-100%) of restorations were rated acceptable in esthetic and functional criteria. Terms of service ranged from two to seventy-six days. In combination with in vitro results, the clinical performance of the Radica VLC system for provisionalization and esthetic diagnostic restorations was judged to be acceptable. The system offers esthetics that are superior to conventional provisional restorations, and should be a valuable option to practitioners considering longer-term provisionalization in complex cases.

  8. Consumer satisfaction in prosthetics and orthotics facilities

    NARCIS (Netherlands)

    Geertzen, J.H.B.; Gankema, H.G.J.; Groothoff, J.W.; Dijkstra, P.U.

    The aim of this study was to assess consumer/patient satisfaction with the services of the prosthetics and orthotics (P&O) facilities in the north of the Netherlands, using a modified SERVQUAL questionnaire. In this questionnaire, consumer interests and experiences are assessed on a 5-point Likert

  9. Successful Thrombolysis of Aortic Prosthetic Valve Thrombosis ...

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    She delivered a normal baby uneventfully in follow up at full term of pregnancy with no complications. Fibrinolytic therapy for mechanical valve thrombosis is a reasonable alternative to surgery in first trimester of pregnancy. KEY WORDS: Prosthetic valve thrombosis; Echocardiography; Streptokinase;. Thrombolysis; Fetus.

  10. Prosthetic Management of Patients Presenting with Juvenile ...

    African Journals Online (AJOL)

    Conclusion: The main objective of prosthetic rehabilitation is the restoration of the integrity of the dental arches. However, the choice of teeth replaced in the partial dentures provided for the patients in this study was based on the choice of the patients, and their choice was determined by aesthetics and affordability.

  11. Promoting prosthetics in the Latino community.

    Science.gov (United States)

    Jaramillo, R; Barabe, J G; Cupp, D

    1995-01-01

    This article describes an effective approach to informing the Latino community about prosthetics. Unlike English, little information on this subject is available in Spanish. The process of obtaining, fabricating, and wearing a prosthesis was interwoven into the teleplay "Milagros." The story concept, video production, and the Latino population's cultural characteristics are discussed. The audience welcomed the opportunity to share the information with others.

  12. Prosthetic Mesh Repair for Incarcerated Inguinal Hernia

    Directory of Open Access Journals (Sweden)

    Cihad Tatar

    2016-08-01

    Full Text Available Background: Incarcerated inguinal hernia is a commonly encountered urgent surgical condition, and tension-free repair is a well-established method for the treatment of noncomplicated cases. However, due to the risk of prosthetic material-related infections, the use of mesh in the repair of strangulated or incarcerated hernia has often been subject to debate. Recent studies have demonstrated that biomaterials represent suitable materials for performing urgent hernia repair. Certain studies recommend mesh repair only for cases where no bowel resection is required; other studies, however, recommend mesh repair for patients requiring bowel resection as well. Aim: The aim of this study was to compare the outcomes of different surgical techniques performed for strangulated hernia, and to evaluate the effect of mesh use on postoperative complications. Study Design: Retrospective cross-sectional study. Methods: This retrospective study was performed with 151 patients who had been admitted to our hospital’s emergency department to undergo surgery for a diagnosis of incarcerated inguinal hernia. The patients were divided into two groups based on the applied surgical technique. Group 1 consisted of 112 patients treated with mesh-based repair techniques, while Group 2 consisted of 39 patients treated with tissue repair techniques. Patients in Group 1 were further divided into two sub-groups: one consisting of patients undergoing bowel resection (Group 3, and the other consisting of patients not undergoing bowel resection (Group 4. Results: In Group 1, it was observed that eight (7.14% of the patients had wound infections, while two (1.78% had hematomas, four (3.57% had seromas, and one (0.89% had relapse. In Group 2, one (2.56% of the patients had a wound infection, while three (7.69% had hematomas, one (2.56% had seroma, and none had relapses. There were no statistically significant differences between the two groups with respect to wound infection

  13. Pregnancy after Prosthetic Aortic Valve Replacement: How Do We Monitor Prosthetic Valvular Function during Pregnancy?

    Directory of Open Access Journals (Sweden)

    Nicole Sahasrabudhe

    2018-01-01

    Full Text Available Background. With modern medicine, many women after structural heart repair are deciding to experience pregnancy. There is a need for further study to identify normal echocardiographic parameters to better assess prosthetic valvular function in pregnancy. In addition, a multidisciplinary approach is essential in managing pregnant patients with complex cardiac conditions. Case. A 22-year-old nulliparous woman with an aortic valve replacement 18 months prior to her pregnancy presented to prenatal care at 20-week gestation. During her prenatal care, serial echocardiography showed a significant increase in the mean gradient across the prosthetic aortic valve. Multidisciplinary management and a serial echocardiography played an integral role in her care that resulted in a successful spontaneous vaginal delivery without complications. Conclusion. Further characterization of the normal echocardiographic parameters in pregnant patients with prosthetic valves is critical to optimize prenatal care for this patient population. This case report is novel in that serial echocardiograms were obtained throughout prenatal care, which showed significant changes across the prosthetic aortic valve. Teaching Points. (1 Further study is needed to identify normal echocardiographic parameters to best assess prosthetic valvular function in pregnancy. (2 Multidisciplinary management is encouraged to optimize prenatal care for women with prosthetic aortic valve replacements.

  14. Comparative roll-over analysis of prosthetic feet.

    Science.gov (United States)

    Curtze, Carolin; Hof, At L; van Keeken, Helco G; Halbertsma, Jan P K; Postema, Klaas; Otten, Bert

    2009-08-07

    A prosthetic foot is a key element of a prosthetic leg, literally forming the basis for a stable and efficient amputee gait. We determined the roll-over characteristics of a broad range of prosthetic feet and examined the effect of a variety of shoes on these characteristics. The body weight of a person acting on a prosthetic foot during roll-over was emulated by means of an inverted pendulum-like apparatus. Parameters measured were the effective radius of curvature, the forward travel of the center of pressure, and the instantaneous radius of curvature of the prosthetic feet. Finally, we discuss how these parameters relate to amputee gait.

  15. Molecular characterization of serologically atypical provisional serovars of Shigella isolates from Kolkata, India.

    Science.gov (United States)

    Dutta, Shanta; Jain, Priyanka; Nandy, Suman; Matsushita, Shigeru; Yoshida, Shin-ichi

    2014-12-01

    During 2000-2004, 13 Shigella strains that were untypable by commercially available antisera were isolated from children Shigella dysenteriae provisional serovar 204/96 (n = 3), Shigella dysenteriae provisional serovar E23507 (n = 1), Shigella dysenteriae provisional serovar I9809-73 (n = 1), Shigella dysenteriae provisional serovar 93-119 (n = 1), Shigella flexneri provisional serovar 88-893 (n = 6) and Shigella boydii provisional serovar E16553 (n = 1). In this study, characterization of those provisional serovars of Shigella was performed with respect to their antimicrobial resistance, plasmids, virulence genes and PFGE profiles. The drug resistant strains (n = 10) of Shigella identified in this study possessed various antibiotic resistance genetic markers like catA (for chloramphenicol resistance); tetA and tetB (for tetracycline resistance); dfrA1 and sul2 (for co-trimoxazole resistance); aadA1, strA and strB (for streptomycin resistance) and blaOXA-1 (for ampicillin resistance). Class 1 and/or class 2 integrons were present in eight resistant strains. Three study strains were pan-susceptible. A single mutation in the gyrA gene (serine to leucine at codon 83) was present in four quinolone resistant strains. The virulence gene ipaH (invasion plasmid antigen H) was uniformly present in all strains in this study, but the stx (Shiga toxin) and set1 (Shigella enterotoxin 1) genes were absent. Other virulence genes like ial (invasion associated locus) and sen (Shigella enterotoxin 2) were occasionally present. A large plasmid of 212 kb and of incompatibility type IncFIIA was present in the majority of the strains (n = 10) and diversity was noticed in the smaller plasmid profiles of these strains even within the same provisional serovars. PFGE profile analysis showed the presence of multiple unrelated clones among the isolates of provisional Shigella serovars. To the best of our knowledge, this is the first report on the phenotypic and

  16. Uptake of radiolabeled leukocytes in prosthetic graft infection

    Energy Technology Data Exchange (ETDEWEB)

    Serota, A.I.; Williams, R.A.; Rose, J.G.; Wilson, S.E.

    1981-07-01

    The utility of radionuclide labeled leukocytes in the demonstration of infection within vascular prostheses was examined. The infrarenal aorta was replaced with a 3 cm Dacron graft in 12 dogs. On the third postoperative day, six of the animals received an intravenous injection of 10(8) Staphylococcus aureus. Labeled leukocyte scans were performed at postoperative days one and three, and then weekly for 8 weeks with indium-111 and technetium-99 labeled autologous leukocytes. When scans showed focal uptake of isotope in the area of prosthetic material, the grafts were aseptically excised and cultured on mannitol-salt agar. Both control and infected animals had retroperitoneal isotope activity in the immediate postoperative period that disappeared by the end of the first week. By the eighth postoperative week, all of the animals that received the bacteremic challenge had both radionuclide concentration in the region of the vascular prosthesis and S. aureus cultured subsequently from the perigraft tissues. None of the control animals had either radionuclide or bacteriologic evidence of infection at the eighth postoperative week. The radiolabeled leukocyte scan is a highly sensitive and specific technique, clinically applicable for the diagnosis of vascular prosthetic infections.

  17. Axial and torsional stiffness of pediatric prosthetic feet.

    Science.gov (United States)

    Taboga, Paolo; Grabowski, Alena M

    2017-02-01

    Prosthetic stiffness likely affects the walking biomechanics of toddlers and children with leg amputations, but the actual stiffness values for prostheses are not reported by manufacturers or in standardized testing procedures. We measured axial (k A ) and torsional (k T ) stiffness from four brands of pediatric prosthetic feet (Trulife, Kingsley Mfg. Co., TRS Incorporated, and College Park Industries) over a range of foot sizes. We applied forces and torques onto prostheses with a materials testing machine that replicated those exhibited in vivo by using the kinetics measured from four non-amputee toddlers (2-3years) during walking. Across brands, k A averaged 35.2kN/m during heel loading, was more stiff during midfoot loading (121.8kN/m, Pfeet. Plantarflexion torsional stiffness (k T1 ), was not statistically different across brands. For every 1cm increase in foot size, k T1 increased 0.16kN·m/rad (Pfeet should be publically reported to health practitioners to ensure evidence-based decisions and meet the specific needs of each patient with a leg amputation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Single-Tooth Rehabilitations Supported by Dental Implants Used in an Immediate-Provisionalization Protocol: Report on Long-Term Outcome with Retrospective Follow-Up.

    Science.gov (United States)

    Maló, Paulo; de Araújo Nobre, Miguel; Lopes, Armando; Ferro, Ana; Gravito, Inês

    2015-10-01

    There is a need for long-term studies evaluating the outcome of single-tooth rehabilitations supported by dental implants in immediate loading. To report the long-term outcome (in excess of 5 years) of single-tooth rehabilitations supported by dental implants in an immediate-provisionalization protocol. This retrospective cohort study included 332 consecutive patients (189 females and 143 males) with an average age of 47 years (range: 16 to 82 years) who were rehabilitated between 1996 and 2006 with 594 single crowns supported by dental implants in immediate loading. Implant success rates were calculated based on implant function and using life tables. Marginal bone levels were measured at 5 and 10 years. Mechanical and biological complications were calculated for the follow-up period between implant insertion and 5 years and every 6 months thereafter. Fifty-four patients dropped out of the study (16.5%). Nineteen patients lost a total of 25 implants (n = 23 in the maxilla; n = 2 in the mandible), rendering a cumulative survival rate of 95.7% at both 5 and 10 years of follow-up. The mean marginal bone levels were 1.56 mm (standard deviation 0.78 mm) and 1.75 mm (standard deviation 0.29 mm) at 5 and 10 years of follow-up. Mechanical complications occurred in 83 patients and 116 implants (19.5%) up to the 10-year follow-up, namely prosthetic screw loosening (2.4%), abutment complications (4.4%), fracture of provisional crowns (9.6%), and fracture of definitive ceramic crowns (3.5%). Biological complications occurred in 58 patients and 79 implants (13.3%) up to the 10-year follow-up, with the majority consisting in peri-implant pathology. Considering the high survival rates and stable marginal bone levels after 10 years, it can be concluded within the limitations of the present study that replacement of single teeth with dental implants in an immediate-provisionalization protocol is a viable and safe treatment option for both maxilla and mandible.

  19. Immediate loading in the maxilla using flapless surgery, implants placed in predetermined positions, and prefabricated provisional restorations: a retrospective 3-year clinical study.

    Science.gov (United States)

    Rocci, Antonio; Martignoni, Massimiliano; Gottlow, Jan

    2003-01-01

    Immediate loading of dental implants shortens the treatment time and makes it possible to give the patient an esthetic appearance during the whole treatment period. The aim of the present study was to evaluate an immediate-loading treatment protocol, which included flapless surgery, implants placed in predetermined positions and connected to prefabricated provisional restorations, and the 3-year clinical results. A total of 97 Brånemark System Mk IV implants (Nobel Biocare AB, Gothenburg, Sweden) with a machined surface were inserted in the maxillas of 46 patients. A presurgical three-dimensional model of the patients' soft tissue and underlying alveolar bone anatomy was created, which allowed the clinician to place the implants in predetermined positions and connect them to prefabricated provisional restorations. A surgical template with drilling guides corresponding to each implant was used. The apical part of the master guide was equipped with a circular "mucotome," which punched out a 5 mm hole in the mucosa to eliminate the need for flap elevation. The patients received 25 fixed partial prostheses and 27 single-tooth restorations. Bone quality and quantity were assessed. Radiographic examinations were performed on the day of surgery/loading and at the 1-, 2-, and 3-year follow-up visits. All implant sites showed intact buccal and lingual bone walls during surgery, confirming the accuracy of the bone-mapping procedure. The prefabricated temporary restorations fitted, meaning that the implants were positioned clinically in the same way as on the cast. Nine implants in eight patients failed during the first 8 weeks of loading. This resulted in a cumulative survival rate of 91% after 3 years of prosthetic load. The survival rate of splinted implants was 94%. The number of failed implants was significantly higher in cases of single-tooth replacements and placement in soft bone sites and smokers. The failed implants were successfully replaced according to a two

  20. CRITERIA FOR THE EVALUATION AND ESTIMATION OF IATROGENIC PROSTHETIC FACTORS – SEMIOLOGY AND SYMPTOMATOLOGY

    Directory of Open Access Journals (Sweden)

    G. LUCA

    2013-12-01

    Full Text Available Introduction: The principles lying at the basis of a balanced dental occlusion cannot be analyzed separately, but only if considering the teeth (and, implicitly, dental occlusion as integrated into the masticatory system, which includes the masticatory muscles, the temporo-mandibu‑ lary joint and the maxillary bones. Scope: The scope of the present study was to correlate and establish the interde‑ pendence between the morpholgically-incorrect prosthetic works and the tissular and functional damages suffered by the neighbouring structures, as a result of some incor‑ rectly-made prosthetic works. Also, the study aims at iden‑ tifying the factors and limits responsible for a prolongued maintenance of such irreversible pathological modificati‑ ons within an asymptomatic zone for the patient. Materials and method: The working hypothesis of the present inves‑ tigation started from the analysis of the various objective signs, versus the morphology of the incorrectly performed prosthetic works. The study, initiated as early as 2009, in a private stomatological clinics (DentEstet, Bucuresti, includes a number of 500 patients (250 women and 250 men, selected among the patients having addressed the stomatological office from various reasons (not always related to the prosthetic pathology of the cases here under investigation. Included in the study have been only the patients with fixed prosthetic works associated with one or several of the previously described objective signs, potentially induced by the iatrogeneicity of the prosthetic works. Results: The pathological effects of the iatrogenic works here under analysis, upon both the antagonistic and prosthetic support teeth, may be clinically identified during a minute examination performed prior to produ‑ cing irreversible final effects (abrasions, fractures, dental mobility, etc.. Such noxious effects of the iatrogenic pros‑ thetic works appear as a false masticatory comfort and as a

  1. Priorities in lower limb prosthetic service delivery based on an international survey of prosthetists in low- and high-income countries.

    Science.gov (United States)

    Wyss, Dominik; Lindsay, Sally; Cleghorn, William L; Andrysek, Jan

    2015-04-01

    Prosthetic services, including the provision of an appropriate prosthesis, are a crucial part of the rehabilitation process for individuals with lower limb amputations. However, globally there exist unique challenges in the delivery of prosthetic services that are limiting rehabilitation outcomes and consequently the well-being and socio-economic status of individuals with lower limb amputations. The objective of this work was to explore the issues related to the provision of appropriate prosthetic technologies and to compare these across different economies of the world. Cross-sectional survey. An online survey was developed and distributed to prosthetic practitioners providing services in countries around the world. An open-coding thematic content analysis procedure was applied to extract key themes from the data. The response codes defined three overall themes of lower limb prosthetic delivery, and several key differences between higher and lower income countries emerged. Namely, a higher emphasis on part/material availability, practitioner training and durability in lower income countries was found. High costs were an issue raised by practitioners in all countries. Practitioners around the world share many of the same concerns; however, some lower income countries face important and pressing issues that limit their ability to provide adequate prosthetic services. This work highlights the most crucial service and technology-related needs, as perceived by trained prosthetic practitioners, of populations requiring lower limb prosthetic treatment around the world. Additionally, the results may be used to prioritize prosthetic-related health-care initiatives led by other researchers, governments and organizations working to improve services internationally. © The International Society for Prosthetics and Orthotics 2013.

  2. Retinal Prosthetics, Optogenetics, and Chemical Photoswitches

    Science.gov (United States)

    2015-01-01

    Three technologies have emerged as therapies to restore light sensing to profoundly blind patients suffering from late-stage retinal degenerations: (1) retinal prosthetics, (2) optogenetics, and (3) chemical photoswitches. Prosthetics are the most mature and the only approach in clinical practice. Prosthetic implants require complex surgical intervention and provide only limited visual resolution but can potentially restore navigational ability to many blind patients. Optogenetics uses viral delivery of type 1 opsin genes from prokaryotes or eukaryote algae to restore light responses in survivor neurons. Targeting and expression remain major problems, but are potentially soluble. Importantly, optogenetics could provide the ultimate in high-resolution vision due to the long persistence of gene expression achieved in animal models. Nevertheless, optogenetics remains challenging to implement in human eyes with large volumes, complex disease progression, and physical barriers to viral penetration. Now, a new generation of photochromic ligands or chemical photoswitches (azobenzene-quaternary ammonium derivatives) can be injected into a degenerated mouse eye and, in minutes to hours, activate light responses in neurons. These photoswitches offer the potential for rapidly and reversibly screening the vision restoration expected in an individual patient. Chemical photoswitch variants that persist in the cell membrane could make them a simple therapy of choice, with resolution and sensitivity equivalent to optogenetics approaches. A major complexity in treating retinal degenerations is retinal remodeling: pathologic network rewiring, molecular reprogramming, and cell death that compromise signaling in the surviving retina. Remodeling forces a choice between upstream and downstream targeting, each engaging different benefits and defects. Prosthetics and optogenetics can be implemented in either mode, but the use of chemical photoswitches is currently limited to downstream

  3. Retinal prosthetics, optogenetics, and chemical photoswitches.

    Science.gov (United States)

    Marc, Robert; Pfeiffer, Rebecca; Jones, Bryan

    2014-10-15

    Three technologies have emerged as therapies to restore light sensing to profoundly blind patients suffering from late-stage retinal degenerations: (1) retinal prosthetics, (2) optogenetics, and (3) chemical photoswitches. Prosthetics are the most mature and the only approach in clinical practice. Prosthetic implants require complex surgical intervention and provide only limited visual resolution but can potentially restore navigational ability to many blind patients. Optogenetics uses viral delivery of type 1 opsin genes from prokaryotes or eukaryote algae to restore light responses in survivor neurons. Targeting and expression remain major problems, but are potentially soluble. Importantly, optogenetics could provide the ultimate in high-resolution vision due to the long persistence of gene expression achieved in animal models. Nevertheless, optogenetics remains challenging to implement in human eyes with large volumes, complex disease progression, and physical barriers to viral penetration. Now, a new generation of photochromic ligands or chemical photoswitches (azobenzene-quaternary ammonium derivatives) can be injected into a degenerated mouse eye and, in minutes to hours, activate light responses in neurons. These photoswitches offer the potential for rapidly and reversibly screening the vision restoration expected in an individual patient. Chemical photoswitch variants that persist in the cell membrane could make them a simple therapy of choice, with resolution and sensitivity equivalent to optogenetics approaches. A major complexity in treating retinal degenerations is retinal remodeling: pathologic network rewiring, molecular reprogramming, and cell death that compromise signaling in the surviving retina. Remodeling forces a choice between upstream and downstream targeting, each engaging different benefits and defects. Prosthetics and optogenetics can be implemented in either mode, but the use of chemical photoswitches is currently limited to downstream

  4. Prosthetic Hand With Two Gripping Fingers

    Science.gov (United States)

    Norton, William E.; Belcher, Jewell B.; Vest, Thomas W.; Carden, James R.

    1993-01-01

    Prosthetic hand developed for amputee who retains significant portion of forearm. Outer end of device is end effector including two fingers, one moved by rotating remaining part of forearm about its longitudinal axis. Main body of end effector is end member supporting fingers, roller bearing assembly, and rack-and-pinion mechanism. Advantage of rack-and-pinion mechanism enables user to open or close gap between fingers with precision and force.

  5. Prosthetic management of an ocular defect

    Directory of Open Access Journals (Sweden)

    Siddesh Kumar Chintal

    2010-01-01

    Full Text Available The disfigurement associated with the loss of an eye can cause significant physical and emotional problems. Various treatment modalities are available, one of which is implants. Although implant has a superior outcome, it may not be advisable in all patients due to economic factors. The present article describes the prosthetic management of an ocular defect with a custom-made ocular prosthesis.

  6. The Prosthetic Workflow in the Digital Era

    OpenAIRE

    Lidia Tordiglione; Michele De Franco; Giovanni Bosetti

    2016-01-01

    The purpose of this retrospective study was to clinically evaluate the benefits of adopting a full digital workflow for the implementation of fixed prosthetic restorations on natural teeth. To evaluate the effectiveness of these protocols, treatment plans were drawn up for 15 patients requiring rehabilitation of one or more natural teeth. All the dental impressions were taken using a Planmeca PlanScan® (Planmeca OY, Helsinki, Finland) intraoral scanner, which provided digital casts on which t...

  7. New developments in prosthetic arm systems

    Directory of Open Access Journals (Sweden)

    Vujaklija I

    2016-07-01

    Full Text Available Ivan Vujaklija,1 Dario Farina,1 Oskar C Aszmann2 1Institute of Neurorehabilitation Systems, Bernstein Focus Neurotechnology Göttingen, University Medical Center Göttingen, Georg-August University, Göttingen, Germany; 2Christian Doppler Laboratory for Restoration of Extremity Function, Division of Plastic and Reconstructive Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria Abstract: Absence of an upper limb leads to severe impairments in everyday life, which can further influence the social and mental state. For these reasons, early developments in cosmetic and body-driven prostheses date some centuries ago, and they have been evolving ever since. Following the end of the Second World War, rapid developments in technology resulted in powered myoelectric hand prosthetics. In the years to come, these devices were common on the market, though they still suffered high user abandonment rates. The reasons for rejection were trifold – insufficient functionality of the hardware, fragile design, and cumbersome control. In the last decade, both academia and industry have reached major improvements concerning technical features of upper limb prosthetics and methods for their interfacing and control. Advanced robotic hands are offered by several vendors and research groups, with a variety of active and passive wrist options that can be articulated across several degrees of freedom. Nowadays, elbow joint designs include active solutions with different weight and power options. Control features are getting progressively more sophisticated, offering options for multiple sensor integration and multi-joint articulation. Latest developments in socket designs are capable of facilitating implantable and multiple surface electromyography sensors in both traditional and osseointegration-based systems. Novel surgical techniques in combination with modern, sophisticated hardware are enabling restoration of dexterous upper limb

  8. Adaptive sports technology and biomechanics: prosthetics.

    Science.gov (United States)

    De Luigi, Arthur Jason; Cooper, Rory A

    2014-08-01

    With the technologic advances in medicine and an emphasis on maintaining physical fitness, the population of athletes with impairments is growing. It is incumbent upon health care practitioners to make every effort to inform these individuals of growing and diverse opportunities and to encourage safe exercise and athletic participation through counseling and education. Given the opportunities for participation in sports for persons with a limb deficiency, the demand for new, innovative prosthetic designs is challenging the clinical and technical expertise of the physician and prosthetist. When generating a prosthetic prescription, physicians and prosthetists should consider the needs and preferences of the athlete with limb deficiency, as well as the functional demands of the chosen sporting activity. The intent of this article is to provide information regarding the current advancements in the adaptive sports technology and biomechanics in the field of prosthetics, and to assist clinicians and their patients in facilitating participation in sporting activities. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  9. The Prosthetic Experience Between Body and Technology

    DEFF Research Database (Denmark)

    Søndergaard, Morten

    2018-01-01

    In this paper, I argue that a prosthetic aesthetic instigated by experimental art practices operate with and within a ‘second nature’ – in-between science and art. Drawing on theories from Dewey and Edelman and examples from Da Vinci, Brancusi, Man Ray, Dali and Stelarc, I am calling for an exper...... in art, which is performing a complex re-design of (the idea and representation of) technology and the body.......In this paper, I argue that a prosthetic aesthetic instigated by experimental art practices operate with and within a ‘second nature’ – in-between science and art. Drawing on theories from Dewey and Edelman and examples from Da Vinci, Brancusi, Man Ray, Dali and Stelarc, I am calling...... for an experience-based analysis of experimental practices operating between body and technology. These practices, which, rather than falling into the category of science fiction or horror cinema as some recent critique from post-human studies would have it, are pointing towards a genealogy of prosthetic experience...

  10. Increasing risk of prosthetic joint infection after total hip arthroplasty

    DEFF Research Database (Denmark)

    Dale, Håvard; Fenstad, Anne M; Hallan, Geir

    2012-01-01

    of primary surgery, and most notably in the first 3 months. The risk of revision due to infection increased in all 4 countries. Risk factors for revision due to infection were male sex, hybrid fixation, cement without antibiotics, and THA performed due to inflammatory disease, hip fracture, or femoral head......Background and purpose The risk of revision due to infection after primary total hip arthroplasty (THA) has been reported to be increasing in Norway. We investigated whether this increase is a common feature in the Nordic countries (Denmark, Finland, Norway, and Sweden). Materials and methods...... explain this increase. We believe that there has been an actual increase in the incidence of prosthetic joint infections after THA....

  11. "Look and feel your best": representations of artificial limb users in prosthetic company advertisements.

    Science.gov (United States)

    Murray, Craig D; Forshaw, Mark J

    2014-01-01

    Artificial limbs (prosthetics) are considered important for keeping the person physically active and avoiding an array of negative health outcomes associated with non-use. Increasingly, the potential users of these limbs are the focus of commercial prosthetic company advertisements. It has been argued that it is important to examine such media representations, not least because people's beliefs regarding health and illness are often forged from the discourses and constructions available to them in such material, but because these representations mediate individual lived experience. This article provides a thematic analysis, drawing upon discourse analysis and semiotics, of textual-pictorial representations of artificial limb users in the advertisements of prosthetic companies. The data set was comprised of advertisements that appeared over a 2-year period in inMotion, an international magazine produced and distributed by a major amputee advocacy group. The findings indicate that dominant societal constructions of work, gender and family are drawn on in depicting artificial limb users. These offer generally positive representations that draw on socially pervasive stereotypes. The findings are discussed in relation to literature concerning the experience and meaning of prosthesis use, and the implications for health professionals working with this group are set out. Implications for Rehabilitation People who lose a limb are increasingly being exposed to advertisements from prosthetic companies. Such advertisements have the potential to foster unrealistic expectations regarding rehabilitation following amputation. Healthcare professionals need to be mindful of how these advertisements mediate lived experience and impact on rehabilitation when planning personal care plans.

  12. Correction of Malpositioned Implants through Periodontal Surgery and Prosthetic Rehabilitation Using Angled Abutment

    Science.gov (United States)

    de Avila, Érica Dorigatti; de Barros-Filho, Luiz Antônio Borelli; de Andrade, Marcelo Ferrarezi; Mollo, Francisco de Assis; de Barros, Luiz Antônio Borelli

    2014-01-01

    When dental implants are malpositioned in relation to the adjacent teeth and alveolar bone or in an excessive buccal or lingual position, the final prosthesis rehabilitation impairs the peri-implant health of the gingival tissues and the aesthetics of the patient. Thus, the purpose of this case was to report and discuss a multidisciplinary protocol for the treatment of a compromised maxillary tooth in a patient with an abscess in his right central incisor due to an excessive buccal implant position. The patient presented with an implant-supported provisional restoration on his right maxillary central incisor and a traumatic injury in his left central incisor. The treatment protocol consisted in (i) abutment substitution to compensate the incorrect angulation of the implant, (ii) clinical crown lengthening, (iii) atraumatic extraction of the left central incisor, and (iv) immediate implant placement. Finally, (v) a custom abutment was fabricated to obtain a harmonious gingival contour around the prosthetic crown. In conclusion, when implants are incorrectly positioned in relation to the adjacent teeth, associated with soft-tissue defects, the challenge to create a harmonious mucogingival contours may be achieved with an interdisciplinary approach and with the placement of an appropriate custom abutment. PMID:24955259

  13. Correction of Malpositioned Implants through Periodontal Surgery and Prosthetic Rehabilitation Using Angled Abutment

    Directory of Open Access Journals (Sweden)

    Érica Dorigatti de Avila

    2014-01-01

    Full Text Available When dental implants are malpositioned in relation to the adjacent teeth and alveolar bone or in an excessive buccal or lingual position, the final prosthesis rehabilitation impairs the peri-implant health of the gingival tissues and the aesthetics of the patient. Thus, the purpose of this case was to report and discuss a multidisciplinary protocol for the treatment of a compromised maxillary tooth in a patient with an abscess in his right central incisor due to an excessive buccal implant position. The patient presented with an implant-supported provisional restoration on his right maxillary central incisor and a traumatic injury in his left central incisor. The treatment protocol consisted in (i abutment substitution to compensate the incorrect angulation of the implant, (ii clinical crown lengthening, (iii atraumatic extraction of the left central incisor, and (iv immediate implant placement. Finally, (v a custom abutment was fabricated to obtain a harmonious gingival contour around the prosthetic crown. In conclusion, when implants are incorrectly positioned in relation to the adjacent teeth, associated with soft-tissue defects, the challenge to create a harmonious mucogingival contours may be achieved with an interdisciplinary approach and with the placement of an appropriate custom abutment.

  14. Cell Adhesion to Acrylic Custom Provisional Abutment Placed on an Immediate Implant: A Case Report.

    Science.gov (United States)

    Saito, Hanae; Hsia, Ru-Ching; Tarnow, Dennis P; Reynolds, Mark A

    2017-02-01

    This article presents the results of a scanning electron microscope (SEM) analysis of the surface of an acrylic custom provisional abutment following first disconnection from a post-extraction immediate implant placement. An implant was placed immediately after extraction, the site was grafted, and a barrier membrane was adapted for graft containment. A custom acrylic shell was then relined, polished, and steam-cleaned prior to being screwed onto the implant. After 5 months of undisturbed healing, the custom provisional abutment was disconnected for the first time and processed for SEM examination. The surface of the custom acrylic abutment revealed well-spread fibroblast-like cells with filopodia inserting into the porous surface. These observations suggest that the surface topography of the acrylic provisional restoration/ abutment can function as a substratum for cellular adhesion and may serve an important role in supporting peri-implant mucosa at the time of immediate implant placement.

  15. Immediate provisional restoration of a single-tooth implant in the esthetic zone: A case report

    Directory of Open Access Journals (Sweden)

    Po-Sung Fu

    2011-02-01

    Full Text Available Immediate implant restoration of single implants may demonstrate a positive effect on peri-implant soft tissue. Placement of a provisional restoration following implant surgery can create soft tissue contours that resemble normal gingival topography before placement of the definitive prosthesis. This article describes a staged approach of the mandibular permanent right central incisor, which was congenital missing. The proper space for restoration of the missing incisor was created through orthodontic treatment. The scheduled implant site was reconstructed using autogenous bone harvested from the chin region. After a healing period of four months, an implant was installed with the connection of a fixed provisional crown to a prefabricated temporary abutment. The soft tissue around the implant healed according to the contours of the provisional restoration and the emergence profile was used to duplicate the definitive restoration. Peri-implant esthetics was achieved through the staged approach and immediate restoration of the implant.

  16. Microleakage of Glass Ionomer-based Provisional Cement in CAD/CAM-Fabricated Interim Crowns: An in vitro Study.

    Science.gov (United States)

    Farah, Ra'fat I; Al-Harethi, Naji

    2016-10-01

    The aim of this study was to compare in vitro the marginal microleakage of glass ionomer-based provisional cement with resin-based provisional cement and zinc oxide non-eugenol (ZONE) provisional cement in computer-aided design and computer-aided manufacturing (CAD/CAM)-fabricated interim restorations. Fifteen intact human premolars were prepared in a standardized manner for complete coverage of crown restorations. Interim crowns for the prepared teeth were then fabricated using CAD/CAM, and the specimens were randomized into three groups of provisional cementing agents (n = 5 each): Glass ionomer-based provisional cement (GC Fuji TEMP LT™), bisphenol-A-glycidyldimethacrylate (Bis-GMA)/ triethylene glycol dimethacrylate (TEGDMA) resin-based cement (UltraTemp® REZ), and ZONE cement (TempBond NE). After 24 hours of storage in distilled water at 37°C, the specimens were thermocycled and then stored again for 24 hours in distilled water at room temperature. Next, the specimens were placed in freshly prepared 2% aqueous methylene blue dye for 24 hours and then embedded in autopolymerizing acrylic resin blocks and sectioned in buccolingual and mesiodistal directions to assess dye penetration using a stereomicroscope. The results were statistically analyzed using a nonparametric Kruskal-Wallis test. Dunn's post hoc test with a Bonferroni correction test was used to compute multiple pairwise comparisons that identified differences among groups; the level of significance was set at p glass ionomer-based provisional cement and the ZONE cement. The provisional cementing agents exhibited different sealing abilities. The Bis-GMA/TEGDMA resin-based provisional cement exhibited the most effective favorable sealing properties against dye penetration compared with the glass ionomer-based provisional cement and conventional ZONE cement. Newly introduced glass ionomer-based provisional cement proved to be inferior to resin-based provisional cement as far as marginal microleakage

  17. Dynamic facial prosthetics for sufferers of facial paralysis.

    Science.gov (United States)

    Coulter, Fergal; Breedon, Philip; Vloeberghs, Michael

    2011-01-01

    This paper discusses the various methods and the materials for the fabrication of active artificial facial muscles. The primary use for these will be the reanimation of paralysed or atrophied muscles in sufferers of non-recoverable unilateral facial paralysis. The prosthetic solution described in this paper is based on sensing muscle motion of the contralateral healthy muscles and replicating that motion across a patient's paralysed side of the face, via solid state and thin film actuators. The development of this facial prosthetic device focused on recreating a varying intensity smile, with emphasis on timing, displacement and the appearance of the wrinkles and folds that commonly appear around the nose and eyes during the expression. An animatronic face was constructed with actuations being made to a silicone representation musculature, using multiple shape-memory alloy cascades. Alongside the artificial muscle physical prototype, a facial expression recognition software system was constructed. This forms the basis of an automated calibration and reconfiguration system for the artificial muscles following implantation, so as to suit the implantee's unique physiognomy. An animatronic model face with silicone musculature was designed and built to evaluate the performance of Shape Memory Alloy artificial muscles, their power control circuitry and software control systems. A dual facial motion sensing system was designed to allow real time control over model - a piezoresistive flex sensor to measure physical motion, and a computer vision system to evaluate real to artificial muscle performance. Analysis of various facial expressions in real subjects was made, which give useful data upon which to base the systems parameter limits. The system performed well, and the various strengths and shortcomings of the materials and methods are reviewed and considered for the next research phase, when new polymer based artificial muscles are constructed and evaluated.

  18. Internal contamination of a 2-component implant system after occlusal loading and provisionally luted reconstruction with or without a washer device.

    Science.gov (United States)

    Rimondini, L; Marin, C; Brunella, F; Fini, M

    2001-12-01

    Microbial internal contamination of oral implants has been suggested as being responsible for inflammatory infiltration of peri-implant tissues at the fixture-abutment interface of 2-stage and 2-component implant systems; it is also considered as a potential source of pathogens. The present in vivo study evaluated contamination of the inner abutment-implant retaining screw, after occlusal loading and provisionally-luted reconstruction with or without a washer device. Eight 2-component oral implants sealed with an o-ring silicon washer device and 9 without a seal were placed in 7 patients with high oral hygiene standards. Two months after prosthetic reconstruction, crowns and internal screws were removed, and organic and inorganic screw contamination was examined by scanning electron microscopy and energy dispersive x-ray spectroscopy (EDS) analysis. An amorphous and crystalline contamination, suggestive of calcium and phosphate compounds, was seen on all screw surfaces. Microbial contamination was more frequently observed in the unsealed group. No differences in bacterial morphotypes were observed between the sealed and unsealed implants. Cocci were the most representative morphotypes, while rods were seldom seen. In clinical situations, leakage occurs at the implant-abutment interface, although bacterial contamination is limited in patients with high oral hygiene standards. Contamination may be reduced by using a washer device.

  19. Myeloid Neoplasms with Germline Predisposition: A New Provisional Entity Within the World Health Organization Classification.

    Science.gov (United States)

    Czuchlewski, David R; Peterson, LoAnn C

    2016-03-01

    The forthcoming update of the World Health Organization (WHO) classification of hematopoietic neoplasms will feature "Myeloid Neoplasms with Germline Predisposition" as a new provisional diagnostic entity. This designation will be applied to some cases of acute myeloid leukemia and myelodysplastic syndrome arising in the setting of constitutional mutations that render patients susceptible to the development of myeloid malignancies. For the diagnostic pathologist, recognizing these cases and confirming the diagnosis will demand a sophisticated grasp of clinical genetics and molecular techniques. This article presents a concise review of this new provisional WHO entity, including strategies for clinical practice. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Control of Prosthetic Hands via the Peripheral Nervous System

    National Research Council Canada - National Science Library

    Ciancio, Anna Lisa; Cordella, Francesca; Barone, Roberto; Romeo, Rocco Antonio; Bellingegni, Alberto Dellacasa; Sacchetti, Rinaldo; Davalli, Angelo; Di Pino, Giovanni; Ranieri, Federico; Di Lazzaro, Vincenzo; Guglielmelli, Eugenio; Zollo, Loredana

    2016-01-01

    ...), and their experimental validation on amputees. The study opens with an in-depth analysis of control solutions and sensorization features of research and commercially available prosthetic hands...

  1. Design of a prosthetic hand with remote actuation.

    Science.gov (United States)

    Scott, Kurt; Perez-Gracia, Alba

    2012-01-01

    One of the main issues of prosthetic hands is to be able to fulfill all the specifications about speed, torque, weight and inertia while placing all the components within the prosthetic hand. This is especially true when full dexterity is required in the prosthesis. In this paper, a new design for a prosthetic hand is presented, which uses remote actuation in order to satisfy most of those requirements. The actuators are to be located in the back of the subject and the transmission is implemented via cables. Other characteristics of this new prosthetic hand include torque limitation and the possibility of switching between underactuated and fully actuated functions.

  2. Factors Associated with Prosthetic Looseness in Lower Limb Amputees.

    Science.gov (United States)

    Phonghanyudh, Thong; Sutpasanon, Taweesak; Hathaiareerug, Chanasak; Devakula, M L Buddhibongsa; Kumnerddee, Wipoo

    2015-12-01

    To determine the factors associated with prosthetic looseness in lower limb amputees in Sisaket province. The present was a cross-sectional descriptive study. Subjects were lower limb amputees who previously obtained prostheses and required prosthetic replacements at the mobile prosthetic laboratory unit under the Prostheses Foundation of H.R.H. the Princess Mother at Khun Han Hospital, Sisaket province, in February 2013. Data including participant characteristics, prosthetic looseness data, and various variables were collected by direct semi-structured interview. Energy expenditures in physical activities were measured using the Thai version of the short format international physical activity questionnaire. Data between participants with and without prosthetic looseness were compared to determine prosthetic loosening associated factors. Among 101 participants enrolled, 33 (32.7%) had prosthetic looseness with average onset of 1.76 ± 1.67 years. Diabetes mellitus was the only significant factor associated with prosthetic looseness from both univariate and multivariate analyses (HR = 7.05, p = 0.002 and HR = 5.93, p = 0.007 respectively). Among the lower limb amputees in Sisaket province, diabetes mellitus was the only factor associated with prosthetic looseness. Therefore, diabetic screening should be supplemented in lower limb amputee assessment protocol. In addition, we recommend that amputees with diabetes mellitus should receive prosthesis check out at approximately

  3. The role of osteoblasts in peri-prosthetic osteolysis.

    LENUS (Irish Health Repository)

    O'Neill, S C

    2013-08-01

    Peri-prosthetic osteolysis and subsequent aseptic loosening is the most common reason for revising total hip replacements. Wear particles originating from the prosthetic components interact with multiple cell types in the peri-prosthetic region resulting in an inflammatory process that ultimately leads to peri-prosthetic bone loss. These cells include macrophages, osteoclasts, osteoblasts and fibroblasts. The majority of research in peri-prosthetic osteolysis has concentrated on the role played by osteoclasts and macrophages. The purpose of this review is to assess the role of the osteoblast in peri-prosthetic osteolysis. In peri-prosthetic osteolysis, wear particles may affect osteoblasts and contribute to the osteolytic process by two mechanisms. First, particles and metallic ions have been shown to inhibit the osteoblast in terms of its ability to secrete mineralised bone matrix, by reducing calcium deposition, alkaline phosphatase activity and its ability to proliferate. Secondly, particles and metallic ions have been shown to stimulate osteoblasts to produce pro inflammatory mediators in vitro. In vivo, these mediators have the potential to attract pro-inflammatory cells to the peri-prosthetic area and stimulate osteoclasts to absorb bone. Further research is needed to fully define the role of the osteoblast in peri-prosthetic osteolysis and to explore its potential role as a therapeutic target in this condition.

  4. Hybrid nanostructured coating for increased resistance of prosthetic devices to staphylococcal colonization

    Science.gov (United States)

    Anghel, Ion; Grumezescu, Alexandru Mihai

    2013-01-01

    Prosthetic medical device-associated infections are responsible for significant morbidity and mortality rates. Novel improved materials and surfaces exhibiting inappropriate conditions for microbial development are urgently required in the medical environment. This study reveals the benefit of using natural Mentha piperita essential oil, combined with a 5 nm core/shell nanosystem-improved surface exhibiting anti-adherence and antibiofilm properties. This strategy reveals a dual role of the nano-oil system; on one hand, inhibiting bacterial adherence and, on the other hand, exhibiting bactericidal effect, the core/shell nanosystem is acting as a controlled releasing machine for the essential oil. Our results demonstrate that this dual nanobiosystem is very efficient also for inhibiting biofilm formation, being a good candidate for the design of novel material surfaces used for prosthetic devices.

  5. Reconsidering evidence-based practice in prosthetic rehabilitation : a shared enterprise

    NARCIS (Netherlands)

    van Twillert, S.; Geertzen, J.; Hemminga, T.; Postema, K.; Lettinga, A.

    Background: A divide is experienced between producers and users of evidence in prosthetic rehabilitation. Objective: To discuss the complexity inherent in establishing evidence-based practice in a prosthetic rehabilitation team illustrated by the case of prosthetic prescription for elderly

  6. Aortic allografts in treatment of aortic valve and ascending aorta prosthetic endocarditis

    Directory of Open Access Journals (Sweden)

    S.V. Spiridonov

    2017-03-01

    Full Text Available The aim – to assess short- and long-term results of aortic root replacement using aortic allografts in patients with prosthetic endocarditis. Materials and methods. Since February 2009 until June 2016 aortic valve and ascending aorta replacement using aortic allografts was performed in 26 patients with prosthetic endocarditis. In 50 % of cases at initial operation aortic valve replacement was performed, in another 50 % of cases – aortic valve and ascending aorta replacement. Echocardiography was performed 10 days, 3, 6 and 12 months, 2, 3 and 5 years after surgery. Analysis of long-term results included all cases of deaths, prosthesis-related complications and recurrence of endocarditis. Results. 30-day mortality was 23.1 %. Extracorporeal membranous oxygenation (ECMO was used only in 5 patients (19.2 %. Four patients were weaned from ECMO. We did not observe any allograft-related complications. During follow-up period there were no cases of reoperation due to structural allograft failure. Relapse of infection occurred in 1 patient (3.8 % four years after the operation and led to lethal outcome. Conclusion. Reoperations using allografts are an effective surgical treatment of prosthetic endocarditis. In majority of cases prosthetic endocarditis was caused by gram-positive cocci (Staphylococcus. In 84.6 % of cases it was associated with destruction of paravalvular structures and abscesses formation. Heart failure was a causative factor of different complications in these patients, which required ECMO in 19.2 % of patients. In 80 % of cases patients were weaned from ECMO. Allografts using for the treatment of prosthetic endocarditis is associated with high resistance to infection and with a significant rate of freedom from recurrence of endocarditis within 3 years after surgery.

  7. Clinical Effectiveness of Using Aesthetic Fixed Prosthetic Appliances with Combined Occlusal Surface

    Directory of Open Access Journals (Sweden)

    Andrii Biben

    2017-06-01

    Conclusions. Aesthetic fixed prosthetic appliances with combined occlusal surface demonstrated high functional and aesthetic characteristics. The use of the USHPS system showed a decisive advantage of milled frameworks and combined occlusal surface over traditional cast ceramic frameworks.The combination of high mechanical, strength and tribological properties of zirconium dioxide and high biological as well as aesthetic properties of ceramic materials helped reveal high clinical characteristics of aesthetic appliances with combined occlusal surface.

  8. The effect of vertical expandable prosthetic titanium rib on growth in congenital scoliosis

    OpenAIRE

    Mehmet Bulent Balioglu; Akif Albayrak; Yunus Emre Akman; Yunus Atici; Deniz Kargin; Mehmet Akif Kaygusuz

    2015-01-01

    Aims: In the treatment of thoracic insufficiency syndrome, the main aim is to maintain spinal and thoracic growth in order to continue respiratory functions. Vertical expandable prosthetic titanium rib (VEPTR) device application is a method of choice especially in the congenital cases with a thoracic deformity. In our study, we evaluated the effect of VEPTR on growth in congenital scoliosis. Materials and Methods: Four female patients in whom VEPTR was applied were retrospectively evaluated. ...

  9. Contribution of prosthetic treatment considerations for dental extractions of permanent teeth

    Directory of Open Access Journals (Sweden)

    Miguel Ángel Fernández-Barrera

    2016-07-01

    Full Text Available Background. Tooth loss is an easily identifiable outcome that summarizes a complex suite of factors in an individual’s history of dental disease and its treatment by dental services over a lifetime. Assessment of overall tooth loss data is essential for epidemiologically evaluating the adequacy of dental care provided at a systems level, as well as for placing in context tooth loss for non-disease causes. For example, when derived from prosthetic treatment planning, the latter may unfortunately lead to some teeth being extracted (pulled for the sake of better comprehensive clinical results. The objective of the present manuscript was to identify the contribution to overall tooth loss, by extraction of permanent teeth because of prosthetic treatment reasons. Material and Methods. A cross-sectional study included sex, age, total number of extractions performed by subject, sextant (anterior vs. posterior, group of teeth (incisors, canines, premolars and molars, upper or lower arch, and the main reason underlying extraction (extraction for any reason vs. prosthetic treatment, in patients 18 years of age and older seeking care at a dental school clinic in Mexico. A multivariate logistic regression model was generated. Results. A total of 749 teeth were extracted in 331 patients; 161 teeth (21.5% of total were extracted for explicit prosthetic treatment indications. As age increased, the likelihood of having an extraction for prosthetic reasons increased 3% (OR = 1.03, p < 0.001. Women (OR = 1.57, p < 0.05 were more likely to be in this situation, and molars (OR = 2.70, p < 0.001 were most at risk. As the total number of extractions increased, the risk of having an extraction for prosthetic reasons decreased (OR = 0.94, p < 0.05. Conclusions. A significant amount (21.5% of the extractions of permanent teeth were performed for prosthetic reasons in this dental school clinical environment; age, sex, type of tooth, and the total number of extractions

  10. Fracture Strength and Failure Mode of Maxillary Implant-Supported Provisional Single Crowns : A Comparison of Composite Resin Crowns Fabricated Directly Over PEEK Abutments and Solid Titanium Abutments

    NARCIS (Netherlands)

    Santing, H.J.; Meijer, Henny J.A.; Raghoebar, G.M.; Ozcan, M.

    2012-01-01

    Background: Polyetheretherketone (PEEK) temporary abutments have been recently introduced for making implant-supported provisional single crowns. Little information is available in the dental literature on the durability of provisional implant-supported restorations. Purpose: The objectives of this

  11. Prosthetic finger phalanges with lifelike skin compliance for low-force social touching interactions

    Directory of Open Access Journals (Sweden)

    Ge Shuzhi

    2011-03-01

    Full Text Available Abstract Background Prosthetic arms and hands that can be controlled by the user's electromyography (EMG signals are emerging. Eventually, these advanced prosthetic devices will be expected to touch and be touched by other people. As realistic as they may look, the currently available prosthetic hands have physical properties that are still far from the characteristics of human skins because they are much stiffer. In this paper, different configurations of synthetic finger phalanges have been investigated for their skin compliance behaviour and have been compared with the phalanges of the human fingers and a phalanx from a commercially available prosthetic hand. Methods Handshake tests were performed to identify which areas on the human hand experience high contact forces. After these areas were determined, experiments were done on selected areas using an indenting probe to obtain the force-displacement curves. Finite element simulations were used to compare the force-displacement results of the synthetic finger phalanx designs with that of the experimental results from the human and prosthetic finger phalanges. The simulation models were used to investigate the effects of (a varying the internal topology of the finger phalanx and (b varying different materials for the internal and external layers. Results and Conclusions During handshake, the high magnitudes of contact forces were observed at the areas where the full grasping enclosure of the other person's hand can be achieved. From these areas, the middle phalanges of the (a little, (b ring, and (c middle fingers were selected. The indentation experiments on these areas showed that a 2 N force corresponds to skin tissue displacements of more than 2 mm. The results from the simulation model show that introducing an open pocket with 2 mm height on the internal structure of synthetic finger phalanges increased the skin compliance of the silicone material to 235% and the polyurethane material to

  12. Prosthetic finger phalanges with lifelike skin compliance for low-force social touching interactions.

    Science.gov (United States)

    Cabibihan, John-John; Pradipta, Raditya; Ge, Shuzhi Sam

    2011-03-30

    Prosthetic arms and hands that can be controlled by the user's electromyography (EMG) signals are emerging. Eventually, these advanced prosthetic devices will be expected to touch and be touched by other people. As realistic as they may look, the currently available prosthetic hands have physical properties that are still far from the characteristics of human skins because they are much stiffer. In this paper, different configurations of synthetic finger phalanges have been investigated for their skin compliance behaviour and have been compared with the phalanges of the human fingers and a phalanx from a commercially available prosthetic hand. Handshake tests were performed to identify which areas on the human hand experience high contact forces. After these areas were determined, experiments were done on selected areas using an indenting probe to obtain the force-displacement curves. Finite element simulations were used to compare the force-displacement results of the synthetic finger phalanx designs with that of the experimental results from the human and prosthetic finger phalanges. The simulation models were used to investigate the effects of (a) varying the internal topology of the finger phalanx and (b) varying different materials for the internal and external layers. During handshake, the high magnitudes of contact forces were observed at the areas where the full grasping enclosure of the other person's hand can be achieved. From these areas, the middle phalanges of the (a) little, (b) ring, and (c) middle fingers were selected. The indentation experiments on these areas showed that a 2 N force corresponds to skin tissue displacements of more than 2 mm. The results from the simulation model show that introducing an open pocket with 2 mm height on the internal structure of synthetic finger phalanges increased the skin compliance of the silicone material to 235% and the polyurethane material to 436%, as compared to a configuration with a solid internal

  13. Tactile sensing means for prosthetic limbs

    Science.gov (United States)

    Scott, W. L. (Inventor)

    1973-01-01

    An improved prosthetic device characterized by a frame and a socket for mounting on the stump of a truncated human appendage is described. Flexible digits extend from the distal end and transducers located within the digits act as sensing devices for detecting tactile stimuli. The transducers are connected through a power circuit with a slave unit supported by a strap and fixed to the stump. The tactile stimuli detected at the sensing devices are reproduced and applied to the skin of the appendage in order to stimulate the sensory organs located therein.

  14. Smart Prosthetic Hand Technology - Phase 2

    Science.gov (United States)

    2011-05-01

    Belgrade/USC Hand (Bekey, Tomovic and Zeljkovic 1990) has small conductive plastic potentiometers compact (35x10x3mm) with good resolution (320ohms...upper limb loss and their reported research priorities. Journal of Prosthetic and Orthotics 8 (1), 2–11. Bekey, G. A., Tomovic , R., Zeljkovic, I...G.R. Tomovic , and I. Zeljkovic. "Control Architecture for the Belgrade/USC Hand." In Dextrous Robot Hands, by S.T. Venkataram and T. Iberall, 136-149

  15. Experimental and failure analysis of the prosthetic finger joint implants

    Science.gov (United States)

    Naidu, Sanjiv H.

    Small joint replacement arthroplasty of the hand is a well accepted surgical procedure to restore function and cosmesis in an individual with a crippled hand. Silicone elastomers have been used as prosthetic material in various small hand joints for well over three decades. Although the clinical science aspects of silicone elastomer failure are well known, the physical science aspects of prosthetic failure are scant and vague. In the following thesis, using both an animal model, and actual retrieved specimens which have failed in human service, experimental and failure analysis of silicone finger joints are presented. Fractured surfaces of retrieved silicone trapezial implants, and silicone finger joint implants were studied with both FESEM and SEM; the mode of failure for silicone trapezium is by wear polishing, whereas the finger joint implants failed either by fatigue fracture or tearing of the elastomer, or a combination of both. Thermal analysis revealed that the retrieved elastomer implants maintained its viscoelastic properties throughout the service period. In order to provide for a more functional and physiologic arthroplasty a novel finger joint (Rolamite prosthesis) is proposed using more recently developed thermoplastic polymers. The following thesis also addresses the outcome of the experimental studies of the Rolamite prosthesis in a rabbit animal model, in addition to the failure analysis of the thermoplastic polymers while in service in an in vivo synovial environment. Results of retrieved Rolamite specimens suggest that the use for thermoplastic elastomers such as block copolymer based elastomers in a synovial environment such as a mammalian joint may very well be limited.

  16. 77 FR 63801 - Aqua-Leisure Industries, Inc., Provisional Acceptance of a Settlement Agreement and Order

    Science.gov (United States)

    2012-10-17

    ... COMMISSION Aqua-Leisure Industries, Inc., Provisional Acceptance of a Settlement Agreement and Order AGENCY... Agreement with Aqua-Leisure Industries, Inc., containing a civil penalty of $650,000.00, within twenty (20... AMERICA CONSUMER PRODUCT SAFETY COMMISSION In the Matter of: Aqua-Leisure Industries, Inc. CPSC Docket No...

  17. 75 FR 1356 - RC2 Corporation, Provisional Acceptance of a Settlement Agreement and Order

    Science.gov (United States)

    2010-01-11

    ... nationwide, and secondarily through RC2's e-commerce websites or as `sub-components' of retail items... through RC2's e-commerce Web sites or as `sub-components' of retail items distributed independently of RC2... accordance with the terms of 16 CFR 1118.20(e). Published below is a provisionally-accepted Settlement...

  18. 77 FR 4023 - Hewlett-Packard Company, Provisional Acceptance of a Settlement Agreement and Order

    Science.gov (United States)

    2012-01-26

    ... COMMISSION Hewlett-Packard Company, Provisional Acceptance of a Settlement Agreement and Order AGENCY... Agreement with Hewlett-Packard Company, containing a civil penalty of $425,000.00, within twenty (20) days... 1118.20, Hewlett-Packard Company (``HP'') and the staff (``Staff'') of the United States Consumer...

  19. 75 FR 23745 - Jo-Ann Stores, Inc., Provisional Acceptance of a Settlement Agreement and Order

    Science.gov (United States)

    2010-05-04

    ... Robbie Ducky products at its retail stores nationwide during those periods for between $5 and $10 per... COMMISSION Jo-Ann Stores, Inc., Provisional Acceptance of a Settlement Agreement and Order AGENCY: Consumer... Agreement with Jo-Ann Stores, Inc., containing a civil penalty of $50,000.00. DATES: Any interested person...

  20. 76 FR 49453 - CVS Pharmacy, Inc., Provisional Acceptance of a Settlement Agreement and Order

    Science.gov (United States)

    2011-08-10

    ... COMMISSION CVS Pharmacy, Inc., Provisional Acceptance of a Settlement Agreement and Order AGENCY: Consumer... Agreement with CVS Pharmacy, Inc., containing a civil penalty of $45,000.00. DATES: Any interested person... 1. In accordance with 16 CFR 1118.20, CVS Pharmacy, Inc. (``CVS'') and the U.S. Consumer Product...

  1. A provisional check list of the reptiles and amphibians of Golden Gate Highlands National Park

    Directory of Open Access Journals (Sweden)

    M.F. Bates

    1991-09-01

    Full Text Available A provisional check list of 26 reptile and amphibian species (8 frog, 8 lizard and 10 snake species occurring in Golden Gate Highlands National Park is presented. The list does not reflect the results of an intensive survey, but is a record of specimens collected in the park and preserved at the National Museum, Bloemfontein.

  2. 75 FR 26939 - Target Corporation: Provisional Acceptance of a Settlement Agreement and Order

    Science.gov (United States)

    2010-05-13

    ... settlements which it provisionally accepts under the Consumer Product Safety Act in the Federal Register in... pursuant to the Consumer Product Safety Act, 15 U.S.C. 2051-2089 (``CPSA''). The Commission is responsible...'s products consisting of the following models: Truck Carry Case; Tiny Playground Set/Dream House...

  3. NGE64/19: Regulaci??n de la jornada laboral, con car??cter provisional

    OpenAIRE

    Universidad de Granada

    2012-01-01

    Resoluci??n de la Gerencia, de 10 de septiembre de 2012, por la que se regula la jornada laboral, con car??cter provisional, para dar cumplimiento a lo establecido en la Ley 2/2012 y en el Real Decreto Ley 20/2012.

  4. 75 FR 55777 - Pro-Pac Distributing Corp., Provisional Acceptance of a Settlement Agreement and Order

    Science.gov (United States)

    2010-09-14

    ... COMMISSION Pro-Pac Distributing Corp., Provisional Acceptance of a Settlement Agreement and Order AGENCY... Agreement with Pro-Pac Distributing Corp., containing a civil penalty of $125,000.00. DATES: Any interested... STATES OF AMERICA CONSUMER PRODUCT SAFETY COMMISSION In the Matter of: Pro-Pac Distributing Corp...

  5. 38 CFR 17.150 - Prosthetic and similar appliances.

    Science.gov (United States)

    2010-07-01

    ... appliances. 17.150 Section 17.150 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS MEDICAL Prosthetic, Sensory, and Rehabilitative Aids § 17.150 Prosthetic and similar appliances. Artificial limbs, braces, orthopedic shoes, hearing aids, wheelchairs, medical accessories, similar...

  6. Prosthetic Frequently Asked Questions for the New Amputee

    Science.gov (United States)

    ... it with your favorite color or pattern. The prosthesis is an extension of you and your style – wear it proudly! Technology continues to change the prosthetic market. With advances in the microprocessor knee and foot, and advanced hands and sockets, prosthetics ...

  7. Prosthetic Rehabilitation in Children: An Alternative Clinical Technique

    Directory of Open Access Journals (Sweden)

    Nádia Carolina Teixeira Marques

    2013-01-01

    Full Text Available Complete and partial removable dentures have been used successfully in numerous patients with oligodontia and/or anodontia. However, there is little information in the literature regarding the principles and guidelines to prosthetic rehabilitation for growing children. This case report describes the management of a young child with oligodontia as well as the treatment planning and the prosthetic rehabilitation technique.

  8. Principles of obstacle avoidance with a transfemoral prosthetic limb

    NARCIS (Netherlands)

    van Keeken, Helco G.; Vrieling, Aline H.; Hof, At L.; Postema, Klaas; Otten, Bert

    2012-01-01

    In this study, conditions that enable a prosthetic knee flexion strategy in transfemoral amputee subjects during obstacle avoidance were investigated. This study explored the hip torque principle and the static ground principle as object avoidance strategies. A prosthetic limb simulator device was

  9. Stiffness and hysteresis properties of some prosthetic feet

    NARCIS (Netherlands)

    van Jaarsveld, H.W.L.; Grootenboer, H.J.; de Vries, J.; Koopman, Hubertus F.J.M.

    1990-01-01

    A prosthetic foot is an important element of a prosthesis, although it is not always fully recognized that the properties of the foot, along with the prosthetic knee joint and the socket, are in part responsible for the stability and metabolic energy cost during walking. The stiffness and the

  10. Prosthetic implantation of the human vestibular system.

    Science.gov (United States)

    Golub, Justin S; Ling, Leo; Nie, Kaibao; Nowack, Amy; Shepherd, Sarah J; Bierer, Steven M; Jameyson, Elyse; Kaneko, Chris R S; Phillips, James O; Rubinstein, Jay T

    2014-01-01

    A functional vestibular prosthesis can be implanted in human such that electrical stimulation of each semicircular canal produces canal-specific eye movements while preserving vestibular and auditory function. A number of vestibular disorders could be treated with prosthetic stimulation of the vestibular end organs. We have previously demonstrated in rhesus monkeys that a vestibular neurostimulator, based on the Nucleus Freedom cochlear implant, can produce canal-specific electrically evoked eye movements while preserving auditory and vestibular function. An investigational device exemption has been obtained from the FDA to study the feasibility of treating uncontrolled Ménière's disease with the device. The UW/Nucleus vestibular implant was implanted in the perilymphatic space adjacent to the three semicircular canal ampullae of a human subject with uncontrolled Ménière's disease. Preoperative and postoperative vestibular and auditory function was assessed. Electrically evoked eye movements were measured at 2 time points postoperatively. Implantation of all semicircular canals was technically feasible. Horizontal canal and auditory function were largely, but not totally, lost. Electrode stimulation in 2 of 3 canals resulted in canal-appropriate eye movements. Over time, stimulation thresholds increased. Prosthetic implantation of the semicircular canals in humans is technically feasible. Electrical stimulation resulted in canal-specific eye movements, although thresholds increased over time. Preservation of native auditory and vestibular function, previously observed in animals, was not demonstrated in a single subject with advanced Ménière's disease.

  11. Is the prosthetic homologue necessary for embodiment?

    Directory of Open Access Journals (Sweden)

    Chelsea Dornfeld

    2016-12-01

    Full Text Available Embodiment is the process by which patients with limb loss come to accept their peripheral device as a natural extension of self. However, there is little guidance as to how exacting the prosthesis must be in order for embodiment to take place: is it necessary for the prosthetic hand to look just like the absent hand? Here, we describe a protocol for testing whether an individual would select a hand that looks like their own from among a selection of 5 hands, and whether the hand selection (regardless of homology is consistent across multiple exposures to the same (but reordered set of candidate hands. Pilot results using healthy volunteers reveals that hand selection is only modestly consistent, and that selection of the prosthetic homologue is atypical (61 of 192 total exposures. Our protocol can be executed in minutes, and makes use of readily available equipment and softwares. We present both a face-to-face and a virtual protocol, for maximum flexibility of implementation.

  12. The use of underactuation in prosthetic grasping

    Directory of Open Access Journals (Sweden)

    P. J. Kyberd

    2011-02-01

    Full Text Available Underactuation as a method of driving prosthetic hands has a long history. The pragmatic requirements of such a device to be light enough to be worn and used regularly have meant that any multi degree of freedom prosthetic hand must have fewer actuators than the usable degrees of freedom. Aesthetics ensures that while the hand needs five fingers, five actuators have considerable mass, and only in recent years has it even been possible to construct a practical anthropomorphic hand with five motors. Thus there is an important trade off as to which fingers are driven, and which joints on which fingers are actuated, and how the forces are distributed to create a functional device. This paper outlines some of the historical solutions created for this problem and includes those designs of recent years that are now beginning to be used in the commercial environment.

    This paper was presented at the IFToMM/ASME International Workshop on Underactuated Grasping (UG2010, 19 August 2010, Montréal, Canada.

  13. The Prosthetic Workflow in the Digital Era

    Directory of Open Access Journals (Sweden)

    Lidia Tordiglione

    2016-01-01

    Full Text Available The purpose of this retrospective study was to clinically evaluate the benefits of adopting a full digital workflow for the implementation of fixed prosthetic restorations on natural teeth. To evaluate the effectiveness of these protocols, treatment plans were drawn up for 15 patients requiring rehabilitation of one or more natural teeth. All the dental impressions were taken using a Planmeca PlanScan® (Planmeca OY, Helsinki, Finland intraoral scanner, which provided digital casts on which the restorations were digitally designed using Exocad® (Exocad GmbH, Germany, 2010 software and fabricated by CAM processing on 5-axis milling machines. A total of 28 single crowns were made from monolithic zirconia, 12 vestibular veneers from lithium disilicate, and 4 three-quarter vestibular veneers with palatal extension. While the restorations were applied, the authors could clinically appreciate the excellent match between the digitally produced prosthetic design and the cemented prostheses, which never required any occlusal or proximal adjustment. Out of all the restorations applied, only one exhibited premature failure and was replaced with no other complications or need for further scanning. From the clinical experience gained using a full digital workflow, the authors can confirm that these work processes enable the fabrication of clinically reliable restorations, with all the benefits that digital methods bring to the dentist, the dental laboratory, and the patient.

  14. The Prosthetic Workflow in the Digital Era.

    Science.gov (United States)

    Tordiglione, Lidia; De Franco, Michele; Bosetti, Giovanni

    2016-01-01

    The purpose of this retrospective study was to clinically evaluate the benefits of adopting a full digital workflow for the implementation of fixed prosthetic restorations on natural teeth. To evaluate the effectiveness of these protocols, treatment plans were drawn up for 15 patients requiring rehabilitation of one or more natural teeth. All the dental impressions were taken using a Planmeca PlanScan® (Planmeca OY, Helsinki, Finland) intraoral scanner, which provided digital casts on which the restorations were digitally designed using Exocad® (Exocad GmbH, Germany, 2010) software and fabricated by CAM processing on 5-axis milling machines. A total of 28 single crowns were made from monolithic zirconia, 12 vestibular veneers from lithium disilicate, and 4 three-quarter vestibular veneers with palatal extension. While the restorations were applied, the authors could clinically appreciate the excellent match between the digitally produced prosthetic design and the cemented prostheses, which never required any occlusal or proximal adjustment. Out of all the restorations applied, only one exhibited premature failure and was replaced with no other complications or need for further scanning. From the clinical experience gained using a full digital workflow, the authors can confirm that these work processes enable the fabrication of clinically reliable restorations, with all the benefits that digital methods bring to the dentist, the dental laboratory, and the patient.

  15. Comparison of some properties of four provisional restorations resin: Trim, Tempron, Acropars TRII & Duralay (Aria Dent

    Directory of Open Access Journals (Sweden)

    Monzavi A.

    2006-08-01

    Full Text Available Background and Aim: Use of provisional restorations is one of the important phases in the treatment of patients who need fixed prosthesis. Some physical properties are required for these materials. The purpose of this study was the comparison of some physical properties of 4 kinds of resins: Trim, Tempron, Duralay (Aria Dent and Acropars TRII. Materials and Methods: In this experimental study, transverse-strength (TS, setting time (ST, polymerization shrinkage (PS and temperature rise (TR during polymerization were tested. In transverse strength test, 5 samples of each resin were made. TS testing was done with an Instron testing machine. ST testing (5 samples in each group was done with Gilmore needle. In PS test, 11 cylindric samples were prepared from each resin and the shrinkage was examined with digital micrometer (up to 24 hours. In TR test, after mixing the powder and liquid of resins (8 samples in each group, the temperature rise was recorded with 10 seconds interval (up to 15 minutes. Data were analyzed with one-way ANOVA and Tukey HSD tests with p<0.05 as the limit of significance. Results: In TS test, all samples of Trim were bent and no fracture was observed, while Tempron and Duralay showed no significant difference. Both Tempron and Duralay revealed high significant difference with Acropars TRII (P <0.01. In ST test, the difference between groups was significant (P<0.01. The lowest ST was observed in Acropars TRII (7 min, and the highest in Tempron (9.53 min. In PS test, significant difference was observed between Trim and Acropars TRII (P<0.01. PS was completed after 120 min in Tempron and Trim groups. However, PS continued to increase in other groups. In TR test, the difference between groups was significant (P<0.05. Duralay showed the highest TR and the lowest was seen in Trim. Conclusion: In this study, Trim showed better properties than other studied groups. Acropars TRII had the lowest strength. The highest temperature rise

  16. Use of prosthetic material in gynaecological surgery | Ramphal ...

    African Journals Online (AJOL)

    No Abstract Available. Obstetrics & Gynaecology Forum Vol. 15 (3) 2005: 19-24. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · http://dx.doi.org/10.4314/ogf.v15i3.30537 · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors ...

  17. Design and development of a new right arm prosthetic kit for a racing cyclist.

    Science.gov (United States)

    Riel, Louis-Philippe; Adam-Côté, Jérôme; Daviault, Stéphane; Salois, Christophe; Laplante-Laberge, Julien; Plante, Jean-Sébastien

    2009-09-01

    This case report describes a newly developed prosthetic arm for a world class trans-humeral amputee cyclist. The proposed solution consists of a new prosthetic kit that was designed to meet requirements of weight, freedom of movement and precise positioning for the disciplines of time-trial, pursuit, road and team sprint. The kit is made of different attachments that can be changed depending on the event the athlete is competing in. The prosthesis is composed of an extended socket made of composite materials, an arm made of aluminum tubes, a universal joint for the junction with the handlebars and different attachments for each bicycle. The system's weight is kept to a minimum using finite element analysis and careful material selection. The universal joint provides the angular degrees of freedom required to allow the athlete to stand up while pedaling, a freedom of movement lost since amputation. In this case report, the athlete's needs are presented and followed by the design of the product using Finite Element modeling. Results are then presented and discussed. This prosthetic kit was used by the athlete for the 2008 Paralympics games in Beijing.

  18. Direct demonstration of bacterial biofilms on prosthetic mesh after ventral herniorrhaphy.

    Science.gov (United States)

    Kathju, Sandeep; Nistico, Laura; Melton-Kreft, Rachael; Lasko, Leslie-Ann; Stoodley, Paul

    2015-02-01

    Prosthetic mesh is employed routinely in the treatment of ventral and parastomal hernias, but its use can lead to major complications, including infection, extrusion, and fistula. Bacterial biofilms have been posited to play a role in mesh-related infection, but although bacteria have been noted to form biofilms on mesh surfaces in vitro, they have never been visualized directly in biofilms on mesh recovered from patients experiencing infectious complications. Five patients who developed complications after ventral hernia repair with prosthetic mesh were operated on again. Explanted mesh was examined for biofilm with confocal laser scanning microscopy (CLSM) and fluorescence in situ hybridization (FISH). In two cases, a novel molecular assay (the Ibis T5000) was used to characterize the biofilm-forming bacteria. The CLSM examination demonstrated adherent biofilms on mesh surfaces in all five patients. Biofilms also were noted on investing fibrous tissue. The FISH study was able to discriminate between bacterial species in polymicrobial biofilms. In two patients the Ibis T5000 detected more species of constituent biofilm bacteria than did standard culture. Removal of the mesh and reconstruction with autologous tissues or biologic materials resolved the presenting complaints in all cases. Bacterial biofilms should be considered an important contributor to the pathology and complications associated with prosthetic mesh implanted in the abdominal wall. If biofilms are present, complete removal of the mesh and repair of the resulting defect without alloplastic materials is an effective intervention.

  19. EFFICIENCY OF PROSTHETIC TREATMENT WITH POST RESECTION PROSTHESES WITH SOLID SUBSTITUTE PART

    Directory of Open Access Journals (Sweden)

    Ivan Gerdzhikov

    2016-08-01

    Full Text Available Aim: The aim of this study is to track the effectiveness of prosthetic treatment with post resection dentures with solid substitute part and their role in the restoration of damaged functions. Materials and methods: The study included 14 patients (9 men and 5 women with different size and location of defects in the upper jaw treated in the period 2010-2016 with post resection prostheses with a solid substitute part. The impressions were taken with irreversible hydrocolloid impression material. The prostheses were completed by heat-curing acrylic with low quantity residual monomer. The effectiveness of prosthetics was evaluated by the method of Mihaylov for both oral-nasal examination of the pressure with the device "Oronasopneumotest." For objectifying and assess the occlusal-articulation ratios was held computerized occlusal analysis with the system T-SCAN 8. Results: The results showed successful obturation and sealing of defects in all patients. It was found satisfactory recovery of the speaking function and normalization of occlusal-articulation ratios. Conclusion: The prosthetic treatment with post resection prostheses with a solid substitute part allows successful recovery of the lost speech and chewing functions, helping to restore self esteem and social rehabilitation of patients.

  20. Graduate Periodontics Programs' Integration of Implant Provisionalization in Core Curricula: Implementation of CODA Standard 4-10.2.d.

    Science.gov (United States)

    Barwacz, Christopher A; Pantzlaff, Ed; Allareddy, Veerasathpurush; Avila-Ortiz, Gustavo

    2017-06-01

    The aim of this descriptive study was to provide an overview of the status of implementation of Commission on Dental Accreditation (CODA) Standard 4-10.2.d (Provisionalization of Dental Implants) by U.S. graduate periodontics programs since its introduction in 2013. Surveys were sent in May 2015 to 56 accredited postdoctoral periodontics program directors to ascertain program director characteristics; status of planning, implementation, and curriculum resulting from adoption of Standard 4-10.2.d; preferred clinical protocols for implant provisionalization; interdisciplinary educational collaborators; and competency assessment mechanisms. The survey response rate was 52% (N=29); the majority were male, aged 55 or older, and had held their position for less than ten years. Among the responding programs, 93% had formal educational curricula established in implant provisionalization. Graduate periodontics (96%) and prosthodontics (63%) faculty members were predominantly involved with curriculum planning. Of these programs, 96% used immediate implant provisionalization, with direct (chairside) provisionalization protocols (86%) being preferred over indirect protocols (14%) and polyethylethylketone provisional abutments (75%) being preferred to titanium (25%) provisional abutments. Straight and concave transmucosal emergence profile designs (46% each) were preferred in teaching, with only 8% of programs favoring convex transmucosal profiles. A majority of responding programs (67%) lacked protocols for communicating to the restorative referral a mechanism to duplicate the mature peri-implant mucosal architecture. Regional location did not play a significant role in any educational component related to implant provisionalization for these graduate periodontal programs. Overall, this study found that a clear majority of graduate periodontics programs had established formal curricula related to implant provisionalization, with substantial clinical and philosophical consensus

  1. Afterword: Provisional Pedagogies toward Imagining Global Mobilities Otherwise

    Science.gov (United States)

    Stein, Sharon; de Oliveira Andreotti, Vanessa

    2017-01-01

    In this afterword we bring insights from the special issue into conversation with the ongoing educational challenges of imagining the world differently. To do so, we consider how global mobilities are conceptualized and materialized within three "pillars" of the architecture of modern existence: the nation-state, global capital, and…

  2. In vitro comparative evaluation of mechanical properties of temporary restorative materials used in fixed partial denture

    Directory of Open Access Journals (Sweden)

    D Saisadan

    2016-01-01

    Full Text Available Introduction: Materials used to fabricate provisional restorations can be classified as acrylics or resin composites. Provisional crows can be either prefabricated or custom made. Acrylics: These materials have been used to fabricate provisional restorations since the 1930s and usually available as powder and liquid. They are the most commonly used materials today for both single-unit and multiple-unit restorations. In general, their popularity is due to their low cost, acceptable esthetics, and versatility. Composites: Composite provisional materials use bis-acryl resin, a hydrophobic material that is similar to bis-GMA. Composites are available as auto-polymerized, dualpolymerized and visible light polymerized. Preformed Crowns: Preformed provisional crowns or matrices usually consist of tooth-shaped shells of plastic, cellulose acetate or metal. They are commercially available in various tooth sizes and are usually selected for a particular tooth anatomy. They are commonly relined with acrylic resin to provide a more custom fit before cementation, but the plastic and metal crown shells can also be cemented directly onto prepared teeth. Aims and Objectives: The aim of this study is to choose a material to serve as a better interim prosthesis and to compare three different properties – flexural strength, compressive strength, and color stability. Materials and Methods: The samples were made with three different provisional materials (Revotek LC, Protemp 4, TemSpan. Result: It was inferred from the study that no one material was superior in all three tested parameters.

  3. Viability of Controlling Prosthetic Hand Utilizing Electroencephalograph (EEG) Dataset Signal

    Science.gov (United States)

    Miskon, Azizi; A/L Thanakodi, Suresh; Raihan Mazlan, Mohd; Mohd Haziq Azhar, Satria; Nooraya Mohd Tawil, Siti

    2016-11-01

    This project presents the development of an artificial hand controlled by Electroencephalograph (EEG) signal datasets for the prosthetic application. The EEG signal datasets were used as to improvise the way to control the prosthetic hand compared to the Electromyograph (EMG). The EMG has disadvantages to a person, who has not used the muscle for a long time and also to person with degenerative issues due to age factor. Thus, the EEG datasets found to be an alternative for EMG. The datasets used in this work were taken from Brain Computer Interface (BCI) Project. The datasets were already classified for open, close and combined movement operations. It served the purpose as an input to control the prosthetic hand by using an Interface system between Microsoft Visual Studio and Arduino. The obtained results reveal the prosthetic hand to be more efficient and faster in response to the EEG datasets with an additional LiPo (Lithium Polymer) battery attached to the prosthetic. Some limitations were also identified in terms of the hand movements, weight of the prosthetic, and the suggestions to improve were concluded in this paper. Overall, the objective of this paper were achieved when the prosthetic hand found to be feasible in operation utilizing the EEG datasets.

  4. Predicting prosthetic prescription after major lower-limb amputation.

    Science.gov (United States)

    Resnik, Linda; Borgia, Matthew

    2015-01-01

    We describe prosthetic limb prescription in the first year following lower-limb amputation and examine the relationship between amputation level, geographic region, and prosthetic prescription. We analyzed 2005 to 2010 Department of Veterans Affairs (VA) Inpatient and Medical Encounters SAS data sets, Vital Status death data, and National Prosthetic Patient Database data for 9,994 Veterans who underwent lower-limb amputation at a VA hospital. Descriptive statistics and bivariates were examined. Cox proportional hazard models identified factors associated with prosthetic prescription. Analyses showed that amputation level was associated with prosthetic prescription. The hazard ratios (HRs) were 1.41 for ankle amputation and 0.46 for transfemoral amputation compared with transtibial amputation. HRs for geographic region were Northeast = 1.49, Upper Midwest = 1.26, and West = 1.39 compared with the South (p prosthetic prescription. Being married was positively associated. After adjusting for patient characteristics, people with ankle amputation were most likely to be prescribed a prosthesis and people with transfemoral amputation were least likely. Geographic variation in prosthetic prescription exists in the VA and further research is needed to explain why.

  5. Passive prosthetic hands and tools: A literature review.

    Science.gov (United States)

    Maat, Bartjan; Smit, Gerwin; Plettenburg, Dick; Breedveld, Paul

    2018-02-01

    The group of passive prostheses consists of prosthetic hands and prosthetic tools. These can either be static or adjustable. Limited research and development on passive prostheses has been performed although many people use these prosthesis types. Although some publications describe passive prostheses, no recent review of the peer-reviewed literature on passive prostheses is available. Review the peer-reviewed literature on passive prostheses for replacement of the hand. Literature review. Four electronic databases were searched using a Boolean combination of relevant keywords. English-language articles relevant to the objective were selected. In all, 38 papers were included in the review. Publications on passive prosthetic hands describe their users, usage, functionality, and problems in activities of daily living. Publications on prosthetic tools mostly focus on sport, recreation, and vehicle driving. Passive hand prostheses receive little attention in prosthetic research and literature. Yet one out of three people with a limb deficiency uses this type of prosthesis. Literature indicates that passive prostheses can be improved on pulling and grasping functions. In the literature, ambiguous names are used for different types of passive prostheses. This causes confusion. We present a new and clear classification of passive prostheses. Clinical relevance This review provides information on the users of passive prosthetic hands and tools, their usage and the functionality. Passive prostheses receive very little attention and low appreciation in literature. Passive prosthetic hands and tools show to be useful to many unilateral amputees and should receive more attention and higher acceptance.

  6. A Miniature Force Sensor for Prosthetic Hands

    Science.gov (United States)

    Platt, Robert; Chu, Mars; Diftler, Myron; Martin, Toby; Valvo, Michael

    2006-01-01

    Tactile sensing is an important part of the development of new prosthetic hands. A number of approaches to establishing an afferent pathway back to the patient for tactile information are becoming available including tactors and direct stimulation of the afferent nerves. Tactile information can also be used by low-level control systems that perform simple tasks for the patient such as establishing a stable grasp and maintaining the grasping forces needed to hold an object. This abstract reports on the design of a small fingertip load cell based on semi-conductor strain gauges. Since this load cell is so small (measuring only 8.5mm in diameter and 6.25 mm in height), it easily fits into the tip of an anthropomorphic mechatronic hand. This load cell is tested by comparing a time series of force and moment data with reference data acquired from a much larger high-precision commercial load cell.

  7. [Improving the speech with a prosthetic construction].

    Science.gov (United States)

    Stalpers, M J; Engelen, M; van der Stappen, J A A M; Weijs, W L J; Takes, R P; van Heumen, C C M

    2016-03-01

    A 12-year-old boy had problems with his speech due to a defect in the soft palate. This defect was caused by the surgical removal of a synovial sarcoma. Testing with a nasometer revealed hypernasality above normal values. Given the size and severity of the defect in the soft palate, the possibility of improving the speech with speech therapy was limited. At a centre for special dentistry an attempt was made with a prosthetic construction to improve the performance of the palate and, in that way, the speech. This construction consisted of a denture with an obturator attached to it. With it, an effective closure of the palate could be achieved. New measurements with acoustic nasometry showed scores within the normal values. The nasality in the speech largely disappeared. The obturator is an effective and relatively easy solution for palatal insufficiency resulting from surgical resection. Intrusive reconstructive surgery can be avoided in this way.

  8. In vitro comparative evaluation of mechanical properties of temporary restorative materials used in fixed partial denture.

    Science.gov (United States)

    Saisadan, D; Manimaran, P; Meenapriya, P K

    2016-10-01

    Materials used to fabricate provisional restorations can be classified as acrylics or resin composites. Provisional crows can be either prefabricated or custom made. These materials have been used to fabricate provisional restorations since the 1930s and usually available as powder and liquid. They are the most commonly used materials today for both single-unit and multiple-unit restorations. In general, their popularity is due to their low cost, acceptable esthetics, and versatility. Composite provisional materials use bis-acryl resin, a hydrophobic material that is similar to bis-GMA. Composites are available as auto-polymerized, dualpolymerized and visible light polymerized. Preformed provisional crowns or matrices usually consist of tooth-shaped shells of plastic, cellulose acetate or metal. They are commercially available in various tooth sizes and are usually selected for a particular tooth anatomy. They are commonly relined with acrylic resin to provide a more custom fit before cementation, but the plastic and metal crown shells can also be cemented directly onto prepared teeth. The aim of this study is to choose a material to serve as a better interim prosthesis and to compare three different properties - flexural strength, compressive strength, and color stability. The samples were made with three different provisional materials (Revotek LC, Protemp 4, TemSpan). It was inferred from the study that no one material was superior in all three tested parameters.

  9. Gait analysis in lower-limb amputation and prosthetic rehabilitation.

    Science.gov (United States)

    Esquenazi, Alberto

    2014-02-01

    Gait analysis combined with sound clinical judgment plays an important role in elucidating the factors involved in the pathologic prosthetic gait and the selection and effects of available interventions to optimize it. Detailed clinical evaluation of walking contributes to the analysis of the prosthetic gait, but evaluation in the gait laboratory using kinetic and kinematic data is often necessary to quantify and identify the particular contributions of the variables impacting the gait with confidence and assess the results of such intervention. The same approach can be considered when selecting prosthetic components and assessing leg length in this patient population. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Thrombolytic therapy in prosthetic valve thrombosis during early pregnancy

    Directory of Open Access Journals (Sweden)

    B.C. Srinivas

    2012-01-01

    Full Text Available Regardless of the improvements in the design of prosthetic heart valves and the use of anticoagulation, systemic embolism and valve thrombosis remains the most dreaded complications of mechanical heart valve replacement. A course of thrombolytic therapy may be considered as a first-line therapy for prosthetic heart valve thrombosis. The safety of thrombolysis in early pregnancy is not known. We describe a primigravida with mitral valve replacement status presenting with acute prosthetic valve thrombosis and treated successfully with intravenous streptokinase.

  11. Mechanical testing of pericardium for manufacturing prosthetic heart valves.

    Science.gov (United States)

    Aguiari, Paola; Fiorese, Michele; Iop, Laura; Gerosa, Gino; Bagno, Andrea

    2016-01-01

    Mammalian pericardia are currently used for the production of percutaneous prosthetic heart valves. The characteristics of biological tissues largely influence the durability of prosthetic devices used in the percutaneous approach and in traditional surgery, too. This paper reviews methodologies employed to assess and compare mechanical properties of pericardial patches from different mammalian species in order to identify the biomaterials adequate for manufacturing prosthetic heart valves. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Glossary of terms used in extraction (IUPAC Provisional Recommendations 2016)

    DEFF Research Database (Denmark)

    Poole, Colin; Mester, Zoltan; Miro, Manuel

    2016-01-01

    in analytical extraction are presented. Exhaustive, microextraction, elevated temperature, microwave- and ultrasound-assisted, parallel batch, flow through systems, and membrane extraction approaches are discussed. An associated tutorial titled “Extraction” provides a detailed introduction to the topic.......Approaches for analytical-scale extraction are developing rapidly as new strategies are implemented to improve sample throughput, to minimize material use in laboratory methods, and to develop on-site capabilities. In this contribution, definitions and recommendations for symbols for the terms used...

  13. Vector-controlled alveolar distraction osteogenesis using an implant-fixed provisional prosthesis: a case report.

    Science.gov (United States)

    Kawashima, Wataru; Takayama, Kenichi; Fujii, Ryosuke; Matsubara, Yuuri; Kirita, Tadaaki

    2013-02-01

    This is a case report of anterosuperior alveolar distraction using an implant-fixed provisional prosthesis. Osteotomy and placement of a distraction device were performed in a healthy 69-year-old woman. To avoid lingual inclination during the distraction period, the device's rod was buried in the labial side of a provisional prosthesis supported by posterior implants. The mandibular bone was obliquely distracted by 0.3 mm every 2 days. Implant insertion was performed, and a good prognosis was anticipated. Inclination is thought to be caused by soft tissue on the lingual side. Many reports propose methods to avoid inclination, but these methods require established support from the teeth and cannot be adapted for an edentulous case. The method reported here is useful for distraction osteogenesis because it can be adapted for edentulous cases.

  14. A provisional bibliography of Asian martial arts periodicals published in Spain (1961-2009

    Directory of Open Access Journals (Sweden)

    Carlos Gutiérrez-García

    2012-07-01

    Full Text Available A provisional bibliography about Asian martial arts periodicals published in Spain from 1961, first journal’s publication date, to 2009 is presented. Asian martial arts journals were just included for preparing this bibliography. Main public documentary centres as well as personal archives were visited for information searching and data mining. Analysis process was complex due to the scarce number of this kind of publications collected in public institutions. 66 periodicals were discovered and several useful elements were detailed for their description and documentary analysis (title, type of publication, period, frequency, issues, editor, place of publication, ISSN and a brief explanation of their editorial line. Despite its provisional character, this bibliography shows the great amount and variety of data contained in these periodicals, turning into a relevant resource for studying the martial arts’ history in Spain.

  15. The Paediatric Rheumatology International Trials Organisation provisional criteria for the evaluation of response to therapy in juvenile dermatomyositis

    DEFF Research Database (Denmark)

    Ruperto, Nicolino; Pistorio, Angela; Ravelli, Angelo

    2010-01-01

    To develop a provisional definition for the evaluation of response to therapy in juvenile dermatomyositis (DM) based on the Paediatric Rheumatology International Trials Organisation juvenile DM core set of variables....

  16. Immediate provisional restoration of a single-tooth implant in the esthetic zone: A case report

    OpenAIRE

    Fu, Po-Sung; Wu, Yi-Min; Tsai, Ching-Fang; Huang, Ta-Ko; Chen, Wen-Cheng; Hung, Chun-Cheng; 傅柏松,; 吳逸民,; 蔡菁芳,; 黃大可; 陳文正,; 洪純正,

    2011-01-01

    Immediate implant restoration of single implants may demonstrate a positive effect on peri-implant soft tissue. Placement of a provisional restoration following implant surgery can create soft tissue contours that resemble normal gingival topography before placement of the definitive prosthesis. This article describes a staged approach of the mandibular permanent right central incisor, which was congenital missing. The proper space for restoration of the missing incisor was created through or...

  17. Biomechanical impact of provisional stenting and balloon dilatation on coronary bifurcation: clinical implications.

    Science.gov (United States)

    Chen, Henry Y; Al-Saadon, Khalid; Louvard, Yves; Kassab, Ghassan S

    2017-07-01

    In-stent restenosis (ISR) and stent thrombosis remain clinically significant problems for bifurcations. Although the role of wall shear stress (WSS) has been well investigated, the role of circumferential wall stresses (CWS) has not been well studied in provisional stenting with and without final kissing balloon (FKB). We hypothesized that the perturbation of CWS at the SB in provisional stenting and balloon dilatation is an important factor in addition to WSS, and, hence, may affect restenosis rates (i.e., higher CWS correlates with higher restenosis). To test this hypothesis, we developed computational models of stent, FKB at bifurcation, and finite element simulations that considered both fluid and solid mechanics of the vessel wall. We computed the stress ratio (CWS/WSS) to show potential correlation with restenosis in clinical studies (i.e., higher stress ratio correlates with higher restenosis). Our simulation results show that stenting in the main branch (MB) increases the maximum CWS in the side branch (SB) and, hence, yields a higher stress ratio in the SB, as compared with the MB. FKB dilatation decreases the CWS and increases WSS, which collectively lowers the stress ratio in the SB. The changes of stress ratio were correlated positively with clinical data in provisional stenting and FKB. Both fluid and solid mechanics need to be evaluated when considering various stenting techniques at bifurcations, as solid stresses also play an important role in clinical outcome. An integrative index of bifurcation mechanics is the stress ratio that considers both CWS and WSS.NEW & NOTEWORTHY Although the role of wall shear stress (WSS) has been well investigated, the role of circumferential wall stresses (CWS) has not been well studied in provisional stenting with and without final kissing balloon. Both fluid and solid mechanics need to be evaluated when considering various stenting techniques at bifurcations. An integrative index of bifurcation mechanics is the

  18. Provisional in-silico biopharmaceutics classification (BCS) to guide oral drug product development

    OpenAIRE

    Wolk O; Agbaria R; Dahan A

    2014-01-01

    Omri Wolk, Riad Agbaria, Arik Dahan Department of Clinical Pharmacology, School of Pharmacy, Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva, Israel Abstract: The main objective of this work was to investigate in-silico predictions of physicochemical properties, in order to guide oral drug development by provisional biopharmaceutics classification system (BCS). Four in-silico methods were used to estimate LogP: group contribution (CLogP) using two different softwa...

  19. Examining the provisional guidelines for weight gain in twin pregnancies: a retrospective cohort study

    OpenAIRE

    Lutsiv, Olha; Hulman, Adam; Woolcott, Christy; Beyene, Joseph; Giglia, Lucy; Armson, B. Anthony; Dodds, Linda; Neupane, Binod; McDonald, Sarah D

    2017-01-01

    Background Weight gain during pregnancy has an important impact on maternal and neonatal health. Unlike the Institute of Medicine (IOM) recommendations for weight gain in singleton pregnancies, those for twin gestations are termed “provisional”, as they are based on limited data. The objectives of this study were to determine the neonatal and maternal outcomes associated with gaining weight below, within and above the IOM provisional guidelines on gestational weight gain in twin pregnancies, ...

  20. The American Volunteer Soldier: Will He Fight. (A Provisional Attitudinal Analysis)

    Science.gov (United States)

    1975-06-02

    NUMBER 4. TITLE (end Subtitlm) THE AMERICAN VOLUNTEER SOLDIER: WILL HE FIGHT? (A PROVISIONAL ATTITUDINAL ANALYSIS) 5. TYPE OF REPORT A PERIOD... Psychologycal Solutions to Social Problems; An Introduction to Social Technology. New York: Academic Press, 1971. Walton, George, COL, USA (Ret...QUESTIONNAIRE. There are several types of questions in this questionnaire. EXAMPLES of the types you will encounter are listed below: FILL IN: [EXAMPLE

  1. Resource-efficient proces chains to manufacture patient-specific prosthetic fingers

    Directory of Open Access Journals (Sweden)

    Hagedorn-Hansen, D.

    2016-05-01

    Full Text Available The high cost of quality prostheses, together with the lack of trained prosthetists, makes it challenging to obtain prosthetic devices in developing communities. Modern 3D digitising techniques and additive manufacturing (AM technologies are gaining popularity in the bio-medical industry and, in the case of prosthesis production, reduce the need for a trained prosthetist. The objective of this research was to develop a new resource-efficient process chain for the manufacturing of prosthetic fingers using additive manufacturing technologies, and to compare it with the traditional (Sculptor process chain. Fused deposition modelling (FDM, open-source FDM, 3-dimensional printing (3DP, and stereolithography (SLA were evaluated in terms of their costs, time, material usage, and aesthetic quality. The surface qualities produced with the different additive manufacturing technologies were also compared. The results showed that 3DP was the preferred technology and was the best candidate for the production of prosthesis in terms of cost, quality, and time for developing communities. SLA produced the highest aesthetic quality prosthesis, but was the most expensive. It was concluded that using the additive manufacturing technology process chain to produce prosthetic fingers is faster and more cost effective than the traditional method.

  2. Influence of immediate loading on provisional restoration in dental implant stability

    Science.gov (United States)

    Ikbal, M.; Odang, R. W.; Indrasari, M.; Dewi, R. S.

    2017-08-01

    The success of dental implant treatment is determined by the primary stability at placement. One factor that could influence this stability is occlusal loading through provisional restoration. Two types of loading protocols are usually used: immediate and delayed loading. However, some controversies remain about the influence of occlusal loading on implant stability. Therefore, the influence of immediate loading on implant stability must be studied. An animal study was conducted by placing nine dental implants in the mandibular jaw of three Macaca fascicularis. Provisional restorations with various occlusal contacts (no, light, and normal contact) were placed on the implant. The implant stability was measured using the Ostell ISQ three times: immediately (baseline) and at the first and second months after implant placement. The implant stability between implants with no and normal occlusal contact as well as light and normal occlusal contact showed significant differences (p implant placement. However, no significant increase (p > 0.05) in implant stability was seen at the baseline and the first and second months after implant placement for all occlusal contact groups. Immediate loading influenced the implant stability, and provisional restoration of implant without occlusal contact showed the highest implant stability.

  3. Surgical treatment of late aortic prosthetic valve endocarditis: 19 years’ experience

    Science.gov (United States)

    Yayla, Tuncer Eylem; Serpil, Tas; Bal, Polat Ebru; Antal, Dönmez Arzu; Adnan, Ak; Mustafa, Akbulut; Bulbul, Serhat; Aksut, Mehmet; Altug, Tuncer

    2014-01-01

    Aim of the study We retrospectively analyzed the results of operations conducted for aortic prosthetic valve endocarditis in a single center over 19 years. Material and methods From February 1992 to January 2011, we performed operations on 27 patients with aortic prosthetic valve endocarditis. Seventeen patients (63.0%) were male, and the mean age was 39.1 ± 14.2 (16-67) years. Blood cultures were positive in 11 patients (40.7%), and the most commonly identified microorganism was Streptococcus (7 patients, 25.9%). The mean duration of follow-up was 8.6 ± 4.7 years (0.5-18.2), adding up to a total of 136.9 patient/years. Results Forty procedures were performed on these 27 patients. The most commonly performed procedure was aortic valve replacement with a prosthetic valve – 16 patients (59.3%). Fifteen patients were operated on during the active phase of infection. In-hospital mortality was observed in 11 patients (40.7%). Postoperatively, 12 patients (44.4%) had low cardiac output, 3 (11.1%) suffered from a heart block; none of them required permanent pacemaker implantation. The actuarial survival for 1 and 5 years was 55.6 ± 9.6% and 47.6 ± 9.7%, respectively. Conclusions Prosthetic valve endocarditis of the aortic valve is a challenging situation for the surgeon. The surgical treatment carries a high mortality rate and long-term survival is low. Among the survivors, however, recurrence and the need for reoperation are unlikely. PMID:26336408

  4. Aortic valve insufficiency in the teenager and young adult: the role of prosthetic valve replacement.

    Science.gov (United States)

    Bradley, Scott M

    2013-10-01

    The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.

  5. Materialism.

    Science.gov (United States)

    Melnyk, Andrew

    2012-05-01

    Materialism is nearly universally assumed by cognitive scientists. Intuitively, materialism says that a person's mental states are nothing over and above his or her material states, while dualism denies this. Philosophers have introduced concepts (e.g., realization and supervenience) to assist in formulating the theses of materialism and dualism with more precision, and distinguished among importantly different versions of each view (e.g., eliminative materialism, substance dualism, and emergentism). They have also clarified the logic of arguments that use empirical findings to support materialism. Finally, they have devised various objections to materialism, objections that therefore serve also as arguments for dualism. These objections typically center around two features of mental states that materialism has had trouble in accommodating. The first feature is intentionality, the property of representing, or being about, objects, properties, and states of affairs external to the mental states. The second feature is phenomenal consciousness, the property possessed by many mental states of there being something it is like for the subject of the mental state to be in that mental state. WIREs Cogn Sci 2012, 3:281-292. doi: 10.1002/wcs.1174 For further resources related to this article, please visit the WIREs website. Copyright © 2012 John Wiley & Sons, Ltd.

  6. [A new implant system for orbital prosthetic rehabilitation: "epiplating mono"].

    Science.gov (United States)

    Schneider, M; Federspil, P A; Neumann, A; Schick, B

    2014-06-01

    A New Implant System for Orbital Prosthetic Rehabilitation: "Epiplating Mono" Prosthetic or episthetic rehabilitation of ear, eye and nose are currently most common performed using magnetic fixation. While at the beginning single implants have been used, now-a-days a more extended approach with plate fixation are recommended to enhance the stability of the anchored magnets. A newly designed implant system epiplating mono is presented that combines the structure of a single implant with additional fixation elements. In a pilot study this new implant system was used in 4 patients for prosthetic orbital rehabilitation. Further experiences with this new implant system are required necessitating long-term experiences of implant stability to define the value of the presented epiplating mono system for prosthetic rehabilitation. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Innovations in prosthetic interfaces for the upper extremity.

    Science.gov (United States)

    Kung, Theodore A; Bueno, Reuben A; Alkhalefah, Ghadah K; Langhals, Nicholas B; Urbanchek, Melanie G; Cederna, Paul S

    2013-12-01

    Advancements in modern robotic technology have led to the development of highly sophisticated upper extremity prosthetic limbs. High-fidelity volitional control of these devices is dependent on the critical interface between the patient and the mechanical prosthesis. Recent innovations in prosthetic interfaces have focused on several control strategies. Targeted muscle reinnervation is currently the most immediately applicable prosthetic control strategy and is particularly indicated in proximal upper extremity amputations. Investigation into various brain interfaces has allowed acquisition of neuroelectric signals directly or indirectly from the central nervous system for prosthetic control. Peripheral nerve interfaces permit signal transduction from both motor and sensory nerves with a higher degree of selectivity. This article reviews the current developments in each of these interface systems and discusses the potential of these approaches to facilitate motor control and sensory feedback in upper extremity neuroprosthetic devices.

  8. Esthetics with prosthetics in case of maxillary canine transposition: A ...

    African Journals Online (AJOL)

    2011-03-16

    .app.medknow. For suggestions and comments do write back to us. Announcement. How to cite this article: Yadav S, Sheorain AK, Madan N, Bajaj P. Esthetics with prosthetics in case of maxillary canine transposition: A ...

  9. Fixed prosthetic treatment in patients with cleft lip and palate

    Directory of Open Access Journals (Sweden)

    Bajevska Jagoda

    2017-01-01

    Full Text Available Introduction. The prosthetic treatment of patients with cleft palate includes various treatment options such as fixed partial dentures, removable partial prosthesis, etc. The type of prosthetic appliance is determined by the oral health of each individual and the circumstances. We presented three adult patients with the cleft lip and palate subjected to prosthetic treatment. Case report. From the possible prosthetic solutions according to the conditions in the oral cavity and the circumstances, fixed partial dentures veneered with composite or ceramic were chosen. A proper relationship between the teeth was reached with the fixed partial dentures, and function established, the phonetics improved and satisfying aesthetics effect accomplished improving the profile appearance of the patient’s face. Plastic surgery of the nose was performed after that. Conclusion. Multidisclipinary treatment is necessary for favourable long-term outcome in cleft lip and palate patients.

  10. Prosthetic motility in pegged versus unpegged integrated porous orbital implants.

    Science.gov (United States)

    Guillinta, Paulo; Vasani, Sunil N; Granet, David B; Kikkawa, Don O

    2003-03-01

    To objectively measure and compare prosthetic motility in pegged versus unpegged orbital implants and to determine subjective patient assessment of motility after the pegging procedure. A prospective case series of 10 patients with integrated porous orbital implants, who had secondary motility peg placement procedure, were studied. Infrared oculography was used to quantitatively assess pegged and unpegged prosthetic eye motility in horizontal and vertical excursions. For horizontal excursions, prosthetic motility in unpegged implants retained an average of 49.6% of measured motility of the contralateral normal eye, which increased to 86.5% with peg placement (Ppeg placement (P>0.3). Nine of 10 patients judged their motility as "significantly improved," and 1 patient gave a rating of "some improvement" after peg placement. Four of 10 patients had granulomas around the peg sites. Objective assessment of prosthetic motility shows a significant increase in horizontal gaze after motility peg placement.

  11. Antithrombotic Therapy in Patients with Prosthetic Heart Valves

    Directory of Open Access Journals (Sweden)

    Mohamed HA

    2009-01-01

    Full Text Available Patients with mechanical valve prostheses require a lifelong anticoagulant treatment. The combined use of Warfarin and low-dose aspirin appears to reduce the risk of valve thrombosis and systemic embolism at a low risk of bleeding. The management of women with prosthetic heart valves during pregnancy poses a particular challenge, as there are no available controlled clinical trials to provide guidelines for effective antithrombotic therapy. Oral anticoagulants, such as Warfarin, cause foetal embryopathy; unfractionated heparin and low-molecular-weight heparin have been reported to be ineffective in preventing thromboembolic complications.This article discusses the available data and the most recent guidelines in the antithrombotic management of patients with prosthetic valves, and antithrombotic therapy in various clinical situations such as pregnant women with prosthetic heart valves, and patients with prosthetic heart valves undergoing noncardiac surgery.

  12. Grasping Pattern Recognition and Grasping Force Estimation For Prosthetic Hands

    OpenAIRE

    Zhang Bing-Ke; Zhong Guo-Liang; Deng Hua

    2016-01-01

    Human’s movement can be decoded by surface electromyography (EMG), and the prosthetic hand can be controlled freely through EMG signal. This paper proposes a grasping pattern and force synchronized decoding method for prosthetic hands. Considering pattern recognition and force estimation simultaneously, this paper analyzes whether different muscle contraction levels affect pattern recognition and whether different grasping modes have impact on force estimation, then proposes two schemes to co...

  13. 24 DOF EMG controlled hybrid actuated prosthetic hand.

    Science.gov (United States)

    Atasoy, A; Kaya, E; Toptas, E; Kuchimov, S; Kaplanoglu, E; Ozkan, M

    2016-08-01

    A complete mechanical design concept of an electromyogram (EMG) controlled hybrid prosthetic hand, with 24 degree of freedom (DOF) anthropomorphic structure is presented. Brushless DC motors along with Shape Memory Alloy (SMA) actuators are used to achieve dexterous functionality. An 8 channel EMG is used for detecting 7 basic hand gestures for control purposes. The prosthetic hand will be integrated with the Neural Network (NNE) based controller in the next phase of the study.

  14. Possibilities of prosthetic upper limb fitting in cycling

    OpenAIRE

    Doležalová, Hana

    2011-01-01

    Bachelor thesis give an overview of possible solutions in upper limbs prosthetic fitting which is suitable for cycling. And provide enough information on modifications that should be performed on a bicycle so that it can be used by humans with upper extremity prostheses. It can be an essential guide for anyone looking for a solution that would allow a person with an amputated upper limb again sit on the bike. Keywords: amputation, upper limb prosthesis, prosthetic fitting, cycling

  15. Guided implant surgery with placement of a presurgical CAD/CAM patient-specific abutment and provisional in the esthetic zone.

    Science.gov (United States)

    Mandelaris, George A; Vlk, Scott D

    2014-01-01

    Parallel use of implant treatment planning software and cone-beam computed tomography (CBCT) can, using certain criteria, consolidate steps and streamline tooth replacement strategies. The authors describe such a case in the esthetic zone whereby flapless extraction and immediate implant placement using CT-guided surgery were performed simultaneously, with placement of a computer-aided design/computer-aided manufactured (CAD/CAM) patient-specific abutment and non-occlusal function provisional in a single visit (supporting the "one-abutment, one-time" concept). An over-retained primary cuspid in a periodontally healthy woman with well-controlled type-2 diabetes was replaced with an implant and CAD/CAM patient-specific abutment in the No. 11 position. A necessary implant-axis angle correction was customized using digital information from a CBCT scan and implant treatment planning software, without the need for site development or a conventional impression. This data integration and streamlined workflow enabled fabrication of a CAD/CAM patient-specific abutment before surgical treatment. The abutment remained in place from implant surgery to the prosthetic phase, with minimal soft-tissue changes, enabling preservation of pink esthetics and expediting treatment. The result was a preserved emergence profile in the presence of high esthetic demands. However, due to slight post-extraction soft-tissue changes, digital reformatting of the abutment was required when the final crown was fabricated, thus limiting the disruption of the biologic width to a one-time occurrence. The importance of case selection for this treatment protocol in the esthetic zone cannot be overemphasized. A thick crestal dentoalveolar bone phenotype (> 1 mm, approaching 2 mm in this case), broad zone of attached and keratinized gingiva (3 mm to 4 mm in this case), adequate peri-implant soft-tissue thickness (> 1 mm in this case), and high primary implant stability (ISQ = 80 in this case) were all

  16. Prosthetic clone and natural human tooth comparison by speckle interferometry

    Science.gov (United States)

    Slangen, Pierre; Corn, Stephane; Fages, Michel; Raynal, Jacques; Cuisinier, Frederic J. G.

    2010-09-01

    New trends in dental prosthodontic interventions tend to preserve the maximum of "body" structure. With the evolution of CAD-CAM techniques, it is now possible to measure "in mouth" the remaining dental tissues. The prosthetic crown is then designed using this shape on which it will be glued on, and also by taking into account the contact surface of the opposite jaw tooth. Several theories discuss on the glue thickness and formulation, but also on the way to evolve to a more biocompatible crown and also new biomechanical concepts. In order to validate these new concepts and materials, and to study the mechanical properties and mechanical integrity of the prosthesis, high resolution optical measurements of the deformations of the glue and the crown are needed. Samples are two intact premolars extracted for orthodontics reasons. The reference sample has no modifications on the tooth while the second sample tooth is shaped to receive a feldspathic ceramic monoblock crown which will be glued. This crown was manufactured with a chairside CAD-CAM system from an intra-oral optical print. The software allows to realize a nearly perfect clone of the reference sample. The necessary space for the glue is also entered with ideal values. This duplication process yields to obtain two samples with identical anatomy for further processing. The glue joint thickness can also be modified if required. The purpose is to compare the behaviour of a natural tooth and its prosthetic clone manufactured with "biomechanical" concepts. Vertical cut samples have been used to deal with planar object observation, and also to look "inside" the tooth. We have developed a complete apparatus enabling the study of the compressive mechanical behaviour of the concerned tooth by speckle interferometry. Because in plane displacements are of great interest for orthodontic measurements1, an optical fiber in-plane sensitive interferometer has been designed. The fibers are wrapped around piezoelectric

  17. [Surgical management of limb prosthetic vascular graft exposure].

    Science.gov (United States)

    Wu, Hao; Wu, Wei-wei; Bai, Ming; Zeng, Rong; Song, Xiao-jun; Chen, Yu; Liu, Chang-wei

    2012-12-01

    To investigate the risk factors and surgical management of limb prosthetic vascular graft exposure. The clinical data of 17 patients suffering from limb prosthetic vascular graft exposure in Peking Union Medical College Hospital from August 2006 to December 2011 were retrospectively analyzed. Among 17 cases, 5 suffered from prosthetic vascular graft exposure after vascular bypass for the lower limb ischemia, whereas 12 were affected after the artificial graft arteriovenous fistula construction in the upper limbs for hemodialysis. The surgical procedures mainly included the local debridement as well as the local flap and transferred muscle-cutaneous flap reconstruction to preserve the prosthetic vascular graft. All 17 patients underwent local flap or muscle-cutaneous flap coverage procedure. After the surgery, the prosthetic vascular graft was successfully salvaged in 14 cases. The total successful rate was 82.4%. The surgery failed in three patients, in whom the prosthetic vascular grafts were finally removed. Local flap and transferred muscle-cutaneous flap reconstruction is an effective surgical management to salvage the exposed grafts.

  18. Instantaneous stiffness and hysteresis of dynamic elastic response prosthetic feet.

    Science.gov (United States)

    Webber, Christina M; Kaufman, Kenton

    2017-10-01

    Dynamic elastic response prosthetic feet are designed to mimic the functional characteristics of the native foot/ankle joint. Numerous designs of dynamic elastic response feet exist which make the prescription process difficult, especially because of the lack of empirical evidence describing the objective performance characteristics of the feet. To quantify the mechanical properties of available dynamic elastic response prosthetic feet, specifically the stiffness and hysteresis. Mechanical testing of dynamic elastic response prosthetic feet. Static Proof Testing in accordance with ISO 10328 was conducted on seven dynamic elastic response prosthetic feet. Load-displacement data were used to calculate the instantaneous stiffness in both the heel and forefoot regions, as well as hysteresis associated with each foot. Heel stiffness was greater than forefoot stiffness for all feet. The heel of the glass composite prosthetic foot was stiffer than the carbon fiber feet and it exhibited less hysteresis. Two different carbon fiber feet had the stiffest forefoot regions. Mechanical testing is a reproducible method that can be used to provide objective evidence about dynamic elastic response prosthetic foot performance and aid in the prescription process. Clinical relevance The quantitative stiffness and hysteresis data from this study can be used by prosthetists to aid the prescription process and make it more objective.

  19. Rotationplasty with vascular reconstruction for prosthetic knee joint infection.

    Science.gov (United States)

    Fujiki, Masahide; Miyamoto, Shimpei; Nakatani, Fumihiko; Kawai, Akira; Sakuraba, Minoru

    2015-01-01

    Rotationplasty is used most often as a function-preserving salvage procedure after resection of sarcomas of the lower extremity; however, it is also used after infection of prosthetic knee joints. Conventional vascular management during rotationplasty is to preserve and coil major vessels, but recently, transection and reanastomosis of the major vessels has been widely performed. However, there has been little discussion regarding the optimal vascular management of rotationplasty after infection of prosthetic knee joints because rotationplasty is rarely performed for this indication. We reviewed four patients who had undergone resection of osteosarcomas of the femur, placement of a prosthetic knee joint, and rotationplasty with vascular reconstruction from 2010 to 2013. The mean interval between prosthetic joint replacement and rotationplasty was 10.4 years and the mean interval between the diagnosis of prosthesis infection and rotationplasty was 7.9 years. Rotationplasty was successful in all patients; however, in one patient, arterial thrombosis developed and necessitated urgent surgical removal and arterial reconstruction. All patients were able to walk independently with a prosthetic limb after rehabilitation. Although there is no consensus regarding the most appropriate method of vascular management during rotationplasty for revision of infected prosthetic joints, vascular transection and reanastomosis is a useful option.

  20. Rotationplasty with Vascular Reconstruction for Prosthetic Knee Joint Infection

    Directory of Open Access Journals (Sweden)

    Masahide Fujiki

    2015-01-01

    Full Text Available Rotationplasty is used most often as a function-preserving salvage procedure after resection of sarcomas of the lower extremity; however, it is also used after infection of prosthetic knee joints. Conventional vascular management during rotationplasty is to preserve and coil major vessels, but recently, transection and reanastomosis of the major vessels has been widely performed. However, there has been little discussion regarding the optimal vascular management of rotationplasty after infection of prosthetic knee joints because rotationplasty is rarely performed for this indication. We reviewed four patients who had undergone resection of osteosarcomas of the femur, placement of a prosthetic knee joint, and rotationplasty with vascular reconstruction from 2010 to 2013. The mean interval between prosthetic joint replacement and rotationplasty was 10.4 years and the mean interval between the diagnosis of prosthesis infection and rotationplasty was 7.9 years. Rotationplasty was successful in all patients; however, in one patient, arterial thrombosis developed and necessitated urgent surgical removal and arterial reconstruction. All patients were able to walk independently with a prosthetic limb after rehabilitation. Although there is no consensus regarding the most appropriate method of vascular management during rotationplasty for revision of infected prosthetic joints, vascular transection and reanastomosis is a useful option.

  1. A Prosthetic Foot Emulator to Optimize Prescription of Prosthetic Feet in Veterans and Service Members with Leg Amputations

    Science.gov (United States)

    2017-09-01

    on Microprocessor -Controlled Prosthetic Knees . Journal of Prosthetics and Orthotics. 2013;25(4S):53-55. 28. Raschke SU, Orendurff MS, Mattie JL, et al... Knee -Ankle Prosthesis Leg on Everyday Community Mobility and Social Interaction Role Site Principal Investigator (A Jayaraman, PI) (5% effort...Funding $2.5 M Purpose To evaluate new prosthesis that has powered controls at both the knee and ankle joints and a new way of controlling this device

  2. Surface EMG in advanced hand prosthetics.

    Science.gov (United States)

    Castellini, Claudio; van der Smagt, Patrick

    2009-01-01

    One of the major problems when dealing with highly dexterous, active hand prostheses is their control by the patient wearing them. With the advances in mechatronics, building prosthetic hands with multiple active degrees of freedom is realisable, but actively controlling the position and especially the exerted force of each finger cannot yet be done naturally. This paper deals with advanced robotic hand control via surface electromyography. Building upon recent results, we show that machine learning, together with a simple downsampling algorithm, can be effectively used to control on-line, in real time, finger position as well as finger force of a highly dexterous robotic hand. The system determines the type of grasp a human subject is willing to use, and the required amount of force involved, with a high degree of accuracy. This represents a remarkable improvement with respect to the state-of-the-art of feed-forward control of dexterous mechanical hands, and opens up a scenario in which amputees will be able to control hand prostheses in a much finer way than it has so far been possible.

  3. Identification of dynamic load for prosthetic structures.

    Science.gov (United States)

    Zhang, Dequan; Han, Xu; Zhang, Zhongpu; Liu, Jie; Jiang, Chao; Yoda, Nobuhiro; Meng, Xianghua; Li, Qing

    2017-12-01

    Dynamic load exists in numerous biomechanical systems, and its identification signifies a critical issue for characterizing dynamic behaviors and studying biomechanical consequence of the systems. This study aims to identify dynamic load in the dental prosthetic structures, namely, 3-unit implant-supported fixed partial denture (I-FPD) and teeth-supported fixed partial denture. The 3-dimensional finite element models were constructed through specific patient's computerized tomography images. A forward algorithm and regularization technique were developed for identifying dynamic load. To verify the effectiveness of the identification method proposed, the I-FPD and teeth-supported fixed partial denture structures were investigated to determine the dynamic loads. For validating the results of inverse identification, an experimental force-measuring system was developed by using a 3-dimensional piezoelectric transducer to measure the dynamic load in the I-FPD structure in vivo. The computationally identified loads were presented with different noise levels to determine their influence on the identification accuracy. The errors between the measured load and identified counterpart were calculated for evaluating the practical applicability of the proposed procedure in biomechanical engineering. This study is expected to serve as a demonstrative role in identifying dynamic loading in biomedical systems, where a direct in vivo measurement may be rather demanding in some areas of interest clinically. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Prosthetic rehabilitation of the upper limb amputee

    Directory of Open Access Journals (Sweden)

    Bernard O′Keeffe

    2011-01-01

    Full Text Available The loss of all or part of the arm is a catastrophic event for a patient and a significant challenge to rehabilitation professionals and prosthetic engineers. The large, upper extremity amputee population in India has, historically, been poorly served, with most having no access to support or being provided with ineffective prostheses. In recent years, the arrival of organisations like Otto Bock has made high quality service standards and devices accessible to more amputees. This review attempts to provide surgeons and other medical professionals with an overview of the multidisciplinary, multistage rehabilitation process and the solution options available. With worldwide upper extremity prosthesis rejection rates at significant levels, the review also describes some of the factors which influence the outcome. This is particularly relevant in the Indian context where the service can involve high cost investments. It is the responsibility of all contributing professionals to guide vulnerable patients through the process and try to maximise the benefit that can be obtained within the resources available.

  5. Peri-prosthetic fracture vibration testing

    Energy Technology Data Exchange (ETDEWEB)

    Cruce, Jesse R [Los Alamos National Laboratory; Erwin, Jenny R [Los Alamos National Laboratory; Remick, Kevin R [Los Alamos National Laboratory; Cornwell, Phillip J [Los Alamos National Laboratory; Menegini, R. Michael [INDIANA UNIV.; Racanelli, Joe [STRYKER ORTHOPARDICS

    2010-11-08

    The purpose of this study was to establish a test setup and vibration analysis method to predict femoral stem seating and prevent bone fracture using accelerometer and force response data from an instrumented stem and impactor. This study builds upon earlier studies to identify a means to supplement a surgeon's tactile and auditory senses by using damage identification techniques normally used for civil and mechanical structures. Testing was conducted using foam cortical shell sawbones prepared for stems of different geometries. Each stem was instrumented with an accelerometer. Two impactor designs were compared: a monolithic impactor and a two-piece impactor, each with an integrated load cell and accelerometer. Acceleration and force measurements were taken in the direction of impaction. Comparisons between different methods of applying an impacting force were made, including a drop tower and a surgical hammer. The effect of varying compliance on the data was also investigated. The ultimate goal of this study was to assist in the design of an integrated portable data acquisition system capable of being used in future cadaveric testing. This paper will discuss the experimental setup and the subsequent results of the comparisons made between impactors, prosthetic geometries, compliances, and impact methods. The results of this study can be used for both future replicate testing as well as in a cadaveric environment.

  6. A comparison of the traditional casting method and the galvanoforming technique in gold alloy prosthetic restorations

    OpenAIRE

    Sarna-Boś Katarzyna; Batyra Agata; Oleszek-Listopad Justyna; Piórkowska-Skrabucha Beata; Borowicz Janusz; Szymańska Jolanta

    2015-01-01

    Gold is a dental material with very good mechanical properties. It is also aesthetic and biocompatible with the tissues of the oral cavity even at 100% purity. Prosthetic restorations made of pure gold or its alloys can be practiced either through a normal casting, as well as through using the galvanoforming technique. The electrolytic method was first introduced into dentistry about 20 years ago and it allows for producing “pure” gold (which means 99.99% Au). The lack of additions of other m...

  7. Quantification of Shear Stresses Within a Transtibial Prosthetic Socket.

    Science.gov (United States)

    Schiff, Adam; Havey, Robery; Carandang, Gerard; Wickman, Amy; Angelico, John; Patwardhan, Avinash; Pinzur, Michael

    2014-08-01

    There is a paucity of objectively recorded data delineating the pattern of weightbearing distribution within the prosthetic socket of patients with transtibial amputation. Our current knowledge is based primarily on information obtained from finite element analysis computer models. Four high-functioning transtibial amputees were fit with similar custom prosthetic sockets. Three load cells were incorporated into each socket at high stress contact areas predicted by computer modeling. Dynamic recording of prosthetic socket loading was accomplished during rising from a sitting position, stepping from a 2-leg stance to a 1-leg stance, and during the initiation of walking. By comparing the loads measured at each of the 3 critical locations, anterior/posterior shear, superior/inferior shear, and end weightbearing were recorded. The same load pattern in all 4 subjects was found during each of the 3 functional activities. The load transmission at the distal end of the amputation residual limbs was negligible. Consistent forces were observed in both the anterior/posterior and superior/inferior planes. Correlation coefficients were used to compare the loads measured in each of the 4 subjects, which ranged from a low of .82 to a high of .98, where a value approaching 1.0 implies a linear relationship amongst subjects. This experimental model appears to have accurately recorded loading within a transtibial prosthetic socket consistent with previously reported finite element analysis computer models. This clinical model will allow objective measurement of weightbearing within the prosthetic socket of transtibial amputees and allow objective comparison of weightbearing distribution within the prosthetic sockets of patients who have undergone creation of different versions of a transtibial amputation residual limb and prosthetic socket designs. © The Author(s) 2014.

  8. Prescription and repair rates of prosthetic limbs in the VA healthcare system: implications for national prosthetic parity.

    Science.gov (United States)

    Etter, Katherine; Borgia, Matthew; Resnik, Linda

    2014-05-22

    Abstract Purpose: To quantify prescription and repair rates of prosthetic limbs in the Department of Veterans Affairs (VA) and explore differences by level, type, and age. Methods: Veterans (N = 32 440) with an initial prosthetic prescription between 2000 and 2010 were classified by amputation level and type. Annual rates of prescription and repair were calculated using person-time and compared by group. Results: Veterans with upper limb amputation had lower annual prescription and repair rates (0.28 and 0.21) compared with those with lower limb amputation (0.40 and 0.56). Myoelectric devices users had higher prescription rates. However, body-powered users had higher repair rates. Prescription and repair rates for microprocessor knee joints were higher than for fluid and friction devices. Veterans under 65 had 0.07 and 0.16 higher rates of prescription and repair than those over 65 (p < 0.0001). Conclusions: Because the VA is unconstrained by co-pays or caps, data on prosthetic prescription and repair can be used to estimate rates that might occur if national prosthetic parity laws were adopted. Given the rates found, it is likely that annual costs would exceed the typical annual and/or lifetime caps in most insurance plans. In states without prosthetic parity laws, such costs likely limit access to needed devices. Implications for Rehabilitation For the almost 2 million people in the United States living with an amputation or congenital limb loss, purchasing and maintaining a prosthetic limb can be costly, with insurances often imposing annual or lifetime caps. Data on prosthetic purchasing and repair is limited and reliant on self-reported information. Because the VA is unconstrained by co-pays or caps, claims data on prosthetic prescription and repair can be used to estimate rates that might occur if national prosthetic parity laws were adopted. Given the rates found, it is likely that annual costs would exceed the typical annual and/or lifetime caps

  9. Recent advancements in prosthetic hand technology.

    Science.gov (United States)

    Saikia, Angana; Mazumdar, Sushmi; Sahai, Nitin; Paul, Sudip; Bhatia, Dinesh; Verma, Suresh; Rohilla, Punit Kumar

    2016-07-01

    Recently, significant advances over the past decade have been made in robotics, artificial intelligence and other cognitive related fields, allowing development of highly sophisticated bio-mimetic robotics systems. In addition, enormous number of robots have been designed and assembled by explicitly realising their biological oriented behaviours. To enhance skill behaviours and adequate grasping abilities in these devices, a new phase of dexterous hands has been developed recently with bio-mimetically oriented and bio-inspired functionalities. The aim in writing this review paper is to present a detailed insight towards the development of the bio-mimetic based dexterous robotic multi-fingered artificial hand. An "ideal" upper limb prosthesis should be perceived as a part of their natural body by the amputee and should replicate sensory-motor capabilities of the amputated limb. Upper-limb amputations are most often the result of sudden trauma to the body, although they also can be caused by malignancy, congenital deficiencies and vascular diseases. This paper discusses the different bio-mimetic approaches using a framework that permits for a common description of biological and technical based hand manipulation behaviour. In particular, the review focuses on a number of developments in the inspired robotic systems. In conclusion, the study found that a huge amount of research efforts in terms of kinematics, dynamics, modelling and control methodologies are being put in to improve the present hand technology, thereby providing more functionality to the prosthetic limb of the amputee. This would improve their quality-of-life and help in performing activities of daily living (ADL) tasks with comparative ease in the near future.

  10. Staphylococcus capitis isolated from prosthetic joint infections.

    Science.gov (United States)

    Tevell, S; Hellmark, B; Nilsdotter-Augustinsson, Å; Söderquist, B

    2017-01-01

    Further knowledge about the clinical and microbiological characteristics of prosthetic joint infections (PJIs) caused by different coagulase-negative staphylococci (CoNS) may facilitate interpretation of microbiological findings and improve treatment algorithms. Staphylococcus capitis is a CoNS with documented potential for both human disease and nosocomial spread. As data on orthopaedic infections are scarce, our aim was to describe the clinical and microbiological characteristics of PJIs caused by S. capitis. This retrospective cohort study included three centres and 21 patients with significant growth of S. capitis during revision surgery for PJI between 2005 and 2014. Clinical data were extracted and further microbiological characterisation of the S. capitis isolates was performed. Multidrug-resistant (≥3 antibiotic groups) S. capitis was detected in 28.6 % of isolates, methicillin resistance in 38.1 % and fluoroquinolone resistance in 14.3 %; no isolates were rifampin-resistant. Heterogeneous glycopeptide-intermediate resistance was detected in 38.1 %. Biofilm-forming ability was common. All episodes were either early post-interventional or chronic, and there were no haematogenous infections. Ten patients experienced monomicrobial infections. Among patients available for evaluation, 86 % of chronic infections and 70 % of early post-interventional infections achieved clinical cure; 90 % of monomicrobial infections remained infection-free. Genetic fingerprinting with repetitive sequence-based polymerase chain reaction (rep-PCR; DiversiLab®) displayed clustering of isolates, suggesting that nosocomial spread might be present. Staphylococcus capitis has the potential to cause PJIs, with infection most likely being contracted during surgery or in the early postoperative period. As S. capitis might be an emerging nosocomial pathogen, surveillance of the prevalence of PJIs caused by S. capitis could be recommended.

  11. Effect of different provisional cement remnant cleaning procedures including Er:YAG laser on shear bond strength of ceramics.

    Science.gov (United States)

    Zortuk, Mustafa; Gumus, Hasan Onder; Kilinc, Halil Ibrahim; Tuncdemir, Ali Riza

    2012-11-01

    The purpose of this study was to evaluate the effect of provisional cement removal by different dentin cleaning protocols (dental explorer, pumice, cleaning bur, Er:YAG laser) on the shear bond strength between ceramic and dentin. In total, 36 caries-free unrestored human third molars were selected as tooth specimens. Provisional restorations were fabricated and cemented with eugenol-free provisional cement. Then, disc-shaped ceramic specimens were fabricated and randomly assigned to four groups of dentin cleaning protocols (n = 9). Group 1 (control): Provisional cements were mechanically removed with a dental explorer. Group 2: The dentin surfaces were treated with a cleaning brush with pumice Group 3: The dentin surfaces were treated with a cleaning bur. Group 4: The provisional cements were removed by an Er:YAG laser. Self-adhesive luting cement was used to bond ceramic discs to dentin surfaces. Shear bond strength (SBS) was measured using a universal testing machine at a 0.05 mm/min crosshead speed. The data were analyzed using a Kolmogorov Smirnov, One-way ANOVA and Tukey HSD tests to perform multiple comparisons (α=0.05). THE DENTIN CLEANING METHODS DID NOT SIGNIFICANTLY AFFECT THE SBS OF CERAMIC DISCS TO DENTIN AS FOLLOWS: dental explorer, pumice, cleaning bur, and Er:YAG laser. The use of different cleaning protocols did not affect the SBS between dentin and ceramic surfaces.

  12. Methods for characterization of mechanical and electrical prosthetic vacuum pumps.

    Science.gov (United States)

    Komolafe, Oluseeni; Wood, Sean; Caldwell, Ryan; Hansen, Andrew; Fatone, Stefania

    2013-01-01

    Despite increasingly widespread adoption of vacuum-assisted suspension systems in prosthetic clinical practices, there remain gaps in the body of scientific knowledge guiding clinicians' choices of existing products. In this study, we identified important pump-performance metrics and developed techniques to objectively characterize the evacuation performance of prosthetic vacuum pumps. The sensitivity of the proposed techniques was assessed by characterizing the evacuation performance of two electrical (Harmony e-Pulse [Ottobock; Duderstadt, Germany] and LimbLogic VS [Ohio Willow Wood; Mt. Sterling, Ohio]) and three mechanical (Harmony P2, Harmony HD, and Harmony P3 [Ottobock]) prosthetic pumps in bench-top testing. Five fixed volume chambers ranging from 33 cm(3) (2 in.(3)) to 197 cm(3) (12 in.(3)) were used to represent different air volume spaces between a prosthetic socket and a liner-clad residual limb. All measurements were obtained at a vacuum gauge pressure of 57.6 kPa (17 inHg). The proposed techniques demonstrated sensitivity to the different electrical and mechanical pumps and, to a lesser degree, to the different setting adjustments of each pump. The sensitivity was less pronounced for the mechanical pumps, and future improvements for testing of mechanical vacuum pumps were proposed. Overall, this study successfully offers techniques feasible as standards for assessing the evacuation performance of prosthetic vacuum pump devices.

  13. Real-time decision fusion for multimodal neural prosthetic devices.

    Science.gov (United States)

    White, James Robert; Levy, Todd; Bishop, William; Beaty, James D

    2010-03-02

    The field of neural prosthetics aims to develop prosthetic limbs with a brain-computer interface (BCI) through which neural activity is decoded into movements. A natural extension of current research is the incorporation of neural activity from multiple modalities to more accurately estimate the user's intent. The challenge remains how to appropriately combine this information in real-time for a neural prosthetic device. Here we propose a framework based on decision fusion, i.e., fusing predictions from several single-modality decoders to produce a more accurate device state estimate. We examine two algorithms for continuous variable decision fusion: the Kalman filter and artificial neural networks (ANNs). Using simulated cortical neural spike signals, we implemented several successful individual neural decoding algorithms, and tested the capabilities of each fusion method in the context of decoding 2-dimensional endpoint trajectories of a neural prosthetic arm. Extensively testing these methods on random trajectories, we find that on average both the Kalman filter and ANNs successfully fuse the individual decoder estimates to produce more accurate predictions. Our results reveal that a fusion-based approach has the potential to improve prediction accuracy over individual decoders of varying quality, and we hope that this work will encourage multimodal neural prosthetics experiments in the future.

  14. Real-time decision fusion for multimodal neural prosthetic devices.

    Directory of Open Access Journals (Sweden)

    James Robert White

    Full Text Available BACKGROUND: The field of neural prosthetics aims to develop prosthetic limbs with a brain-computer interface (BCI through which neural activity is decoded into movements. A natural extension of current research is the incorporation of neural activity from multiple modalities to more accurately estimate the user's intent. The challenge remains how to appropriately combine this information in real-time for a neural prosthetic device. METHODOLOGY/PRINCIPAL FINDINGS: Here we propose a framework based on decision fusion, i.e., fusing predictions from several single-modality decoders to produce a more accurate device state estimate. We examine two algorithms for continuous variable decision fusion: the Kalman filter and artificial neural networks (ANNs. Using simulated cortical neural spike signals, we implemented several successful individual neural decoding algorithms, and tested the capabilities of each fusion method in the context of decoding 2-dimensional endpoint trajectories of a neural prosthetic arm. Extensively testing these methods on random trajectories, we find that on average both the Kalman filter and ANNs successfully fuse the individual decoder estimates to produce more accurate predictions. CONCLUSIONS: Our results reveal that a fusion-based approach has the potential to improve prediction accuracy over individual decoders of varying quality, and we hope that this work will encourage multimodal neural prosthetics experiments in the future.

  15. Corynebacterium CDC group G native and prosthetic valve endocarditis

    Directory of Open Access Journals (Sweden)

    Adil Sattar

    2015-08-01

    Full Text Available We report the first case of native and recurrent prosthetic valve endocarditis with Corynebacterium CDC group G, a rarely reported cause of infective endocarditis (IE. Previously, there have been only two cases reported for prosthetic valve IE caused by these organisms. A 69-year-old female with a known history of mitral valve regurgitation presented with a 3-day history of high-grade fever, pleuritic chest pain and cough. Echocardiography confirmed findings of mitral valve thickening consistent with endocarditis, which subsequently progressed to become large and mobile vegetations. Both sets of blood cultures taken on admission were positive for Corynebacterium CDC group G. Despite removal of a long-term venous access port, the patient’s presumed source of line associated bacteremia, mitral valve replacement, and aggressive antibiotic therapy, the patient had recurrence of vegetations on the prosthetic valve. She underwent replacement of her prosthetic mitral valve in the subsequent 2 weeks, before she progressed to disseminated intravascular coagulation and expired. Although they are typically considered contaminants, corynebacteria, in the appropriate clinical setting, should be recognized, identified, and treated as potentially life-threatening infections, particularly in the case of line-associated bacteremias, and native and prosthetic valve endocarditis.

  16. Heel-region properties of prosthetic feet and shoes.

    Science.gov (United States)

    Klute, Glenn K; Berge, Jocelyn S; Segal, Ava D

    2004-07-01

    The properties of the prosthetic components prescribed to amputees have the potential to ameliorate or exacerbate their comfort, mobility, and health. To measure the difference in heel-region structural properties of currently available prosthetic feet and shoes, we simulated the period of initial heel-ground contact with a pendulum apparatus. The energy dissipation capacity of the various prosthetic feet ranged from 33.6% to 52.6% of the input energy. Donning a shoe had a large effect. Energy dissipation of a Seattle Lightfoot 2 prosthetic foot was 45.3%, while addition of a walking, running, and orthopedic shoe increased energy dissipation to 63.0%, 73.0%, and 82.4%, respectively. The force versus deformation response to impact was modeled as a hardening spring in parallel with a position-dependent damping element. A nonlinear least-squares curve fit produced model coefficients useful for predicting the heel-region impact response of both prosthetic feet and shoes.

  17. Corynebacterium CDC Group G Native and Prosthetic Valve Endocarditis.

    Science.gov (United States)

    Sattar, Adil; Yu, Siegfried; Koirala, Janak

    2015-08-11

    We report the first case of native and recurrent prosthetic valve endocarditis with Corynebacterium CDC group G, a rarely reported cause of infective endocarditis (IE). Previously, there have been only two cases reported for prosthetic valve IE caused by these organisms. A 69-year-old female with a known history of mitral valve regurgitation presented with a 3-day history of high-grade fever, pleuritic chest pain and cough. Echocardiography confirmed findings of mitral valve thickening consistent with endocarditis, which subsequently progressed to become large and mobile vegetations. Both sets of blood cultures taken on admission were positive for Corynebacterium CDC group G. Despite removal of a long-term venous access port, the patient's presumed source of line associated bacteremia, mitral valve replacement, and aggressive antibiotic therapy, the patient had recurrence of vegetations on the prosthetic valve. She underwent replacement of her prosthetic mitral valve in the subsequent 2 weeks, before she progressed to disseminated intravascular coagulation and expired. Although they are typically considered contaminants, corynebacteria, in the appropriate clinical setting, should be recognized, identified, and treated as potentially life-threatening infections, particularly in the case of line-associated bacteremias, and native and prosthetic valve endocarditis.

  18. Nanoscale Properties of Neural Cell Prosthetic and Astrocyte Response

    Science.gov (United States)

    Flowers, D. A.; Ayres, V. M.; Delgado-Rivera, R.; Ahmed, I.; Meiners, S. A.

    2009-03-01

    Preliminary data from in-vivo investigations (rat model) suggest that a nanofiber prosthetic device of fibroblast growth factor-2 (FGF-2)-modified nanofibers can correctly guide regenerating axons across an injury gap with aligned functional recovery. Scanning Probe Recognition Microscopy (SPRM) with auto-tracking of individual nanofibers is used for investigation of the key nanoscale properties of the nanofiber prosthetic device for central nervous system tissue engineering and repair. The key properties under SPRM investigation include nanofiber stiffness and surface roughness, nanofiber curvature, nanofiber mesh density and porosity, and growth factor presentation and distribution. Each of these factors has been demonstrated to have global effects on cell morphology, function, proliferation, morphogenesis, migration, and differentiation. The effect of FGF-2 modification on the key nanoscale properties is investigated. Results from the nanofiber prosthetic properties investigations are correlated with astrocyte response to unmodified and FGF-2 modified scaffolds, using 2D planar substrates as a control.

  19. Prosthetic hand control using motion discrimination from EMG signals.

    Science.gov (United States)

    Kurisu, Naoyuki; Tsujiuchi, Nobutaka; Koizumi, Takayuki

    2009-01-01

    In this report, we improve the motion discrimination method from electromyogram (EMG) for a prosthetic hand and propose prosthetic hand control. In the past, we proved that a motion discrimination method using conic models could discriminate three hand motions without the incorrect discriminations that the elbow motions cause. In this research, to increase discrimination accuracy of motion discrimination using conic models, we propose a feature extraction method using quadratic polynomials. Additionally, because many prosthetic hands using motion discrimination have constant motion speed that can't be controlled, we propose an angular velocity generation method using multiple regression models. We verified these methods by controlling the 3D hand model. In the experiment, the proposed method could discriminate five motions at a rate of above 90 percent without the incorrect discriminations that elbow motions cause. Moreover, the wrist joint angle of the 3D hand model could be controlled by standard variation of 3[deg] or less.

  20. Three-Dimensional Printing of Prosthetic Hands for Children.

    Science.gov (United States)

    Burn, Matthew B; Ta, Anderson; Gogola, Gloria R

    2016-05-01

    Children with hand reductions, whether congenital or traumatic, have unique prosthetic needs. They present a challenge because of their continually changing size due to physical growth as well as changing needs due to psychosocial development. Conventional prosthetics are becoming more technologically advanced and increasingly complex. Although these are welcome advances for adults, the concomitant increases in weight, moving parts, and cost are not beneficial for children. Pediatric prosthetic needs may be better met with simpler solutions. Three-dimensional printing can be used to fabricate rugged, light-weight, easily replaceable, and very low cost assistive hands for children. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  1. Prosthetic mitral valve thrombosis in pregnancy: from thrombolysis to anticoagulation.

    Science.gov (United States)

    Cardoso, Gonçalo; Aguiar, Carlos; Andrade, Maria João; Patrício, Lino; Freire, Isabel; Serrano, Fátima; Anjos, Rui; Mendes, Miguel

    2015-01-01

    Pregnant women with mechanical prosthetic heart valves are at increased risk for valve thrombosis. Management decisions for this life-threatening complication are complex. Open-heart surgery has a very high risk of maternal mortality and fetal loss. Bleeding and embolic risks associated with thrombolytic agents, the limited efficacy of thrombolysis in certain subgroups, and a lack of experience in the setting of pregnancy raise important concerns. We report a case of mitral prosthetic valve thrombosis in early pregnancy, which was successfully treated with streptokinase. Ten years later, the same patient had an uneventful pregnancy, throughout which acenocoumarol was maintained. With this case we review the prevention (with oral anticoagulant therapy) and treatment of prosthetic valve thrombosis during pregnancy, which is important for both obstetrician and cardiologist. Copyright © 2014 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  2. Surgical-prosthetic treatment of large mandibular cysts

    Directory of Open Access Journals (Sweden)

    Džambas Ljubiša D.

    2003-01-01

    Full Text Available This paper presents a combined surgical-prosthetic procedure of reconstructing mandibular bone defect in a 53 year old patient, following enucleation of a mandibular cyst (Cystectomy Partsch II. After a thorough diagnostic evaluation, a surgical procedure was planned with the particular attention to the nature of the disease, patient’s condition, size and extension of the cyst, tissue loss, and the possibilities of prosthetic management of a mandibular bone defect with partial postresection dental prosthesis. It is of great importance to point to the significance of teamwork of a maxillofacial surgeon and a specialist in prosthodontics. This kind of cooperation provided very effective and less risky soft tissue, as well as bone tissue regeneration (osteogenesis. The patient’s recovery was fast, and he could return to his daily activities and work without significant changes regarding quality of life after surgery and prosthetic treatment.

  3. Radiological evaluation of prosthetic fit in below-the-knee amputees

    Energy Technology Data Exchange (ETDEWEB)

    Newton, R.L.; Schreiber, M.H.; Morgan, D.

    1988-06-01

    Fourteen artificial limbs in eight adult patients with below the knee amputations were evaluated for prosthetic fit by several radiological parameters. The best objective means of evaluation of prosthetic adequacy is piston action.

  4. Immediate implant placement and provisionalization with simultaneous guided bone regeneration in the esthetic zone

    Directory of Open Access Journals (Sweden)

    Chih-Long Chen

    2011-03-01

    Full Text Available The procedure for immediate implant placement and provisionalization is time-saving, possibly with only one surgical intervention required, although allowing maximal preservation of peri-implant tissues. In this case, we extracted a fractured maxillary right central incisor of a 46-year-old woman with high esthetic expectations, and a transmucosal implant was immediately installed. Simultaneous guided bone regeneration was performed to correct the defects at the facial side of the socket and augment the alveolar ridge horizontally. Primary stability of the implant body and wound closure without tension were confirmed. Connection of a 15° angled abutment and fabrication of a provisional acrylic resin crown without occlusal contact were also completed in the same appointment. After intensive follow-up and soft-tissue molding for 6 months, the customized zirconia abutment and all-ceramic crown were definitively fabricated. During the 18-month follow-up period, the patient was satisfied with the esthetic and functional results.

  5. Finite element analysis of provisional structures of implant-supported complete prostheses.

    Science.gov (United States)

    Carneiro, Bruno Albuquerque; de Brito, Rui Barbosa; França, Fabiana Mantovani Gomes

    2014-04-01

    The use of provisional resin implant-supported complete dentures is a fast and safe procedure to restore mastication and esthetics of patients soon after surgery and during the adaptation phase to the new denture. This study assessed stress distribution of provisional implant-supported fixed dentures and the all-on-4 concept using self-curing acrylic resin (Tempron) and bis-acrylic resin (Luxatemp) to simulate functional loads through the three-dimensional finite element method. Solidworks software was used to build three-dimensional models using acrylic resin (Tempron, model A) and bis-acrylic resin (Luxatemp, model B) for denture captions. Two loading patterns were applied on each model: (1) right unilateral axial loading of 150 N on the occlusal surfaces of posterior teeth and (2) oblique loading vector of 150 N at 45°. The results showed that higher stress was found on the bone crest below oblique load application with a maximum value of 187.57 MPa on model A and 167.45 MPa on model B. It was concluded that model B improved stress distribution on the denture compared with model A.

  6. The development of measurement tools for prosthetic eye research.

    Science.gov (United States)

    Pine, Keith Raymond; Sloan, Brian; Jacobs, Robert John

    2013-01-01

    The aim was to develop tools to measure the condition of ocular prostheses and the socket's response to prosthetic eyewear. A novel staining technique for displaying deposits on prosthetic eyes was developed. Equal interval perceptual grading scales for measuring inferior palpebral conjunctival inflammation, and anterior and posterior stained surface deposits on prosthetic eyes were developed from 800 photographs of 43 volunteers. The photographs for each scale were chosen by the authors. A group of four ophthalmologists, three optometrists and three senior students was consulted about selection criteria and asked to position the photographs along a 1.5 m rule to determine equal intervals. Photographs judged not to represent exactly equal perceptual intervals were exchanged with others from the original pool. The final scales (a five-photograph scale for inflammation and two 11 photograph scales for deposits) were assessed for inter-rater reliability and test-retest reliability by groups of senior optometry students. Standard deviations for inter-rater reliability tests were 0.52 scale units for the inflammation scale, 0.99 for the anterior surface deposits scale and 1.03 for the posterior surface deposits scale. The standard deviation of the test-retest differences for inflammation was 0.6 scale units and for both anterior and posterior surface deposits it was 0.71. A novel technique for displaying and measuring the intensity and extent of deposit formation on prosthetic eye surfaces has been described. The two equal interval perceptual grading scales that have been developed to quantify the extent of deposit formation together with the equal interval perceptual scale for grading severity of palpebral conjunctival inflammation will for the first time allow the effects of prosthetic eye wear to be evaluated. Further research to validate the scale for palpebral conjunctival inflammation in a clinical setting is recommended. The technique for staining deposits on

  7. Maxillofacial prosthetics training and practice profiles in the United States.

    Science.gov (United States)

    Sheets, James L; Yuan, Judy Chia-Chun; Sukotjo, Cortino; Davis, Betsy K; Wee, Alvin G

    2017-10-01

    The motivation of maxillofacial prosthodontists to go into fellowship training and specific procedures in maxillofacial prosthetics practice once they have completed training has not been previously evaluated. The purpose of this study was to survey maxillofacial prosthodontists in the United States to investigate their reasons for pursuing maxillofacial prosthetic training and their practice profiles. In June 2015, a survey was sent to all US maxillofacial prosthodontists asking for descriptive demographics, their reasoning as to what prompted entrance into a maxillofacial prosthetic program, and their practice pattern. Frequencies, percentages, means, and standard deviations were calculated and reported. The survey response rate was 60.4%. The main reason for pursuing maxillofacial training was primarily personal satisfaction, prosthodontic residency exposure, and mentorship rather than media exposure and compensation. The time spent in prosthodontic practice varied among practitioners, with the majority of practice time spent accomplishing standard prosthodontic procedures (65.59%) versus maxillofacial (25.53%) or surgical procedures (9.67%). Of 12 clinical maxillofacial procedures inquired about, the most prevalent were obturators, dental oncology, and mandibular resections. This study reveals that personal satisfaction, mentorship, and prosthodontic residency exposure were the reasons most prosthodontists pursued an additional year of maxillofacial prosthetic fellowship. Most were very satisfied with their training and chosen career path and would recommend an additional year of training. The majority of maxillofacial prosthodontists provided maxillofacial prosthetic treatment for approximately one fourth of their practice time. The most common procedures performed were obturators, dental oncology, and mandibular resections. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. [Application and outlook of three-dimensional printing in prosthetic dentistry].

    Science.gov (United States)

    Sun, Y C; Li, R; Zhou, Y S; Wang, Y

    2017-06-09

    At present, three-dimensional (3D) printing has been applied in many aspects in the field of prosthodontics, such as dental models, wax patterns, guide plates, dental restoration and customized implants. The common forming principles include light curing, sintering and melting-condensation, the materials include pure wax, resin, metal and ceramics. However, the printing precision and the strength of multi-material integrated forming, remains to be improved. In addition, as a technology by which the internal structure of a material can be customized manufacturing, further advantage of 3D printing used in the manufacture of dental restoration lies in the customization functional bionic micro-structures, but the related research is still in its infancy. The review briefly summarizes the commonly used 3D printing crafts in prosthetic dentistry, and details clinical applications and evaluations, provides references for clinical decision and further research.

  9. Prosthetic Rehabilitation of Ocular Defect resulting from Pediatric Retinoblastoma.

    Science.gov (United States)

    Janya, Suma; Gubrellay, Priyanka; Purwar, Anupam; Khanna, Shally

    2014-01-01

    Ocular defects result from tumor, congenital anomaly and external injury not only lead to serious impairment of function and esthetics but also make the patient psychologically disabled. Prosthetic rehabilitation attempts to restore these disfgurements may improve esthetic, level of function, general psychologic improvement and quality of life. This clinical report details an attempt to rehabilitate a pediatric patient who has undergone orbital enucleation resulting from retinoblastoma with the aid of custom ocular prosthesis using commercially available prefabricated eye shell. How to cite this article: Janya S, Gubrellay P, Purwar A, Khanna S. Prosthetic Rehabilitation of Ocular Defect resulting from Pediatric Retinoblastoma. Int J Clin Pediatr Dent 2014; 7(3):209-212.

  10. Prosthetic limbs on display: from maker to user

    Directory of Open Access Journals (Sweden)

    Sophie Goggins

    2017-11-01

    Full Text Available Prosthetic devices have been used in museums to tell clinical, technical and personal stories. Here we reflect on the ways artificial limbs and their users were represented in recent museum projects at the Royal College of Surgeons of England and at National Museums Scotland. We consider how these meaningful artefacts illuminate three overlapping themes in museum scholarship and practice: the representation of disabled people and disability in museums; reflections on conflict-acquired limb loss; and the presence or otherwise of user or patient voice in interpretation. In working with and representing people who design and wear prosthetics we advocate a balance between narratives of technique and of use.

  11. Towards a Smart Semi-Active Prosthetic Leg: Preliminary Assessment and Testing

    OpenAIRE

    Awad, MI; Abouhossein, A; Dehghani-Sanij, AA; Richardson, R.; Moser, D.; Zahedi, S; Bradley, D.

    2016-01-01

    This paper presents a development of a semi-active prosthetic knee, which can work in both active and passive modes based on the energy required during the gait cycle of various activities of daily livings (ADLs). The prosthetic limb is equipped with various sensors to measure the kinematic and kinetic parameters of both prosthetic limbs. This prosthetic knee is designed to be back-drivable in passive mode to provide a potential use in energy regeneration when there negative energy across the...

  12. Integrated Electrode Arrays for Neuro-Prosthetic Implants

    Science.gov (United States)

    Brandon, Erik; Mojarradi, Mohammede

    2003-01-01

    Arrays of electrodes integrated with chip-scale packages and silicon-based integrated circuits have been proposed for use as medical electronic implants, including neuro-prosthetic devices that might be implanted in brains of patients who suffer from strokes, spinal-cord injuries, or amyotrophic lateral sclerosis. The electrodes of such a device would pick up signals from neurons in the cerebral cortex, and the integrated circuit would perform acquisition and preprocessing of signal data. The output of the integrated circuit could be used to generate, for example, commands for a robotic arm. Electrode arrays capable of acquiring electrical signals from neurons already exist, but heretofore, there has been no convenient means to integrate these arrays with integrated-circuit chips. Such integration is needed in order to eliminate the need for the extensive cabling now used to pass neural signals to data-acquisition and -processing equipment outside the body. The proposed integration would enable progress toward neuro-prostheses that would be less restrictive of patients mobility. An array of electrodes would comprise a set of thin wires of suitable length and composition protruding from and supported by a fine-pitch micro-ball grid array or chip-scale package (see figure). The associated integrated circuit would be mounted on the package face opposite the probe face, using the solder bumps (the balls of the ball grid array) to make the electrical connections between the probes and the input terminals of the integrated circuit. The key innovation is the insertion of probe wires of the appropriate length and material into the solder bumps through a reflow process, thereby fixing the probes in place and electrically connecting them with the integrated circuit. The probes could be tailored to any distribution of lengths and made of any suitable metal that could be drawn into fine wires. Furthermore, the wires could be coated with an insulating layer using anodization or

  13. Lightweight custom composite prosthetic components using an additive manufacturing-based molding technique.

    Science.gov (United States)

    Leddy, Michael T; Belter, Joseph T; Gemmell, Kevin D; Dollar, Aaron M

    2015-01-01

    Additive manufacturing techniques are becoming more prominent and cost-effective as 3D printing becomes higher quality and more inexpensive. The idea of 3D printed prosthetics components promises affordable, customizable devices, but these systems currently have major shortcomings in durability and function. In this paper, we propose a fabrication method for custom composite prostheses utilizing additive manufacturing, allowing for customizability, as well the durability of professional prosthetics. The manufacturing process is completed using 3D printed molds in a multi-stage molding system, which creates a custom finger or palm with a lightweight epoxy foam core, a durable composite outer shell, and soft urethane gripping surfaces. The composite material was compared to 3D printed and aluminum materials using a three-point bending test to compare stiffness, as well as gravimetric measurements to compare weight. The composite finger demonstrates the largest stiffness with the lowest weight compared to other tested fingers, as well as having customizability and lower cost, proving to potentially be a substantial benefit to the development of upper-limb prostheses.

  14. Pre-prosthetic surgical alterations in maxillectomy to enhance the prosthetic prognoses as part of rehabilitation of oral cancer patient.

    Science.gov (United States)

    El Fattah, H; Zaghloul, A; Pedemonte, E; Escuin, T

    2012-03-01

    After maxillectomy, prosthetic restoration of the resulting defect is an essential step because it signals the beginning of patient's rehabilitation. The obturator used to restore the defect should be comfortable, restore adequate speech, deglutition, mastication, and be cosmetically acceptable, success will depend on the size and location of the defect and the quantity and integrity of the remaining structures, in addition to pre-prosthetic surgical preparation of defect site. Preoperative cooperation between the oncologist surgeon and the maxillofacial surgeon may allow obturation of a resultant defect by preservation of the premaxilla or the tuberosity on the defect side and maintaining the alveolar bone or teeth adjacent to the defect. This study evaluates the importance of pre-prosthetic surgical alterations at the time maxillectomy on the enhancement of the prosthetic prognoses as part of the rehabilitation of oral cancer patient. The study was carried out between 2003- 2008, on 66 cancer patients(41 male-25 female) age ranged from 33 to 72 years, at National Cancer Institute, Cairo University, whom underwent maxillectomy surgery to remove malignant tumor as a part of cancer treatment. Patients were divided in two groups. Group A: Resection of maxilla followed by preprosthetic surgical preparation. Twenty-four cancer patients (13 male - 11 female). Group B: Resection of maxilla without any preprosthetic surgical preparation. Forty-two cancer patients (28 male-14 female). Outcome variables measured included facial contour and aesthetic results, speech understandability, ability to eat solid foods, oronasal separation, socializing outside the home, and return-to-work status. Flap success and donor site morbidity were also studied. To improve the prosthetic restoration of maxillary defect resulting maxillary resection as part treatment of maxillofacial tumor depends on the close cooperation between prosthodontist and surgeon, by combination of pre-prosthetic

  15. Current State of Craniofacial Prosthetic Rehabilitation

    NARCIS (Netherlands)

    Ariani, Nina; Visser, Anita; van Oort, Robert P.; Kusdhany, Lindawati; Rahardjo, Tri Budi W.; Krom, Bastiaan P.; van der Mei, Henny C.; Vissink, Arjan

    2013-01-01

    Purpose: This study aimed to review the current state of the techniques and materials used to rehabilitate maxillofacial defects. Materials and Methods: The MEDLINE and EMBASE databases were searched for articles pertinent to maxillofacial prostheses published from January 1990 to July 2011. The

  16. Rehabilitation regimes based upon psychophysical studies of prosthetic vision

    Science.gov (United States)

    Chen, S. C.; Suaning, G. J.; Morley, J. W.; Lovell, N. H.

    2009-06-01

    Human trials of prototype visual prostheses have successfully elicited visual percepts (phosphenes) in the visual field of implant recipients blinded through retinitis pigmentosa and age-related macular degeneration. Researchers are progressing rapidly towards a device that utilizes individual phosphenes as the elementary building blocks to compose a visual scene. This form of prosthetic vision is expected, in the near term, to have low resolution, large inter-phosphene gaps, distorted spatial distribution of phosphenes, restricted field of view, an eccentrically located phosphene field and limited number of expressible luminance levels. In order to fully realize the potential of these devices, there needs to be a training and rehabilitation program which aims to assist the prosthesis recipients to understand what they are seeing, and also to adapt their viewing habits to optimize the performance of the device. Based on the literature of psychophysical studies in simulated and real prosthetic vision, this paper proposes a comprehensive, theoretical training regime for a prosthesis recipient: visual search, visual acuity, reading, face/object recognition, hand-eye coordination and navigation. The aim of these tasks is to train the recipients to conduct visual scanning, eccentric viewing and reading, discerning low-contrast visual information, and coordinating bodily actions for visual-guided tasks under prosthetic vision. These skills have been identified as playing an important role in making prosthetic vision functional for the daily activities of their recipients.

  17. Different Intraorbital Implant Situations and Ocular Prosthetic Rehabilitation.

    Science.gov (United States)

    Aggarwal, Himanshi; Kumar, Pradeep; Eachempati, Prashanti; Alvi, Habib A

    2016-12-01

    Enucleation is the removal of the entire globe of the eye and a portion of the optic nerve, while evisceration involves the removal of the contents of the globe leaving the sclera, extraocular muscles, and optic nerve. Following enucleation or evisceration, intraorbital implants are routinely placed to enhance the prosthetic outcome in addition to restoring the lost orbital volume. Current practice employs intraorbital implants made of nonporous silicone, hydroxyapatite, or porous polyethylene. Intraorbital implant selection and placement, being a highly demanding procedure in terms of knowledge, skill, and expertise, may be associated with a multiplicity of technical and surgical errors. Complications are usually minimal with these implants, but they do occur. The literature reveals many articles related to intraorbital implants, their benefits, and complications; however, the literature regarding the effect of various intraorbital implant situations on the subsequent prosthetic rehabilitation is markedly scarce. Moreover, the need for interdisciplinary surgical and prosthetic interventions required for successful rehabilitation in cases of compromised implant situations has been underemphasized. Hence, this review aimed to evaluate the effect of different intraorbital implant situations on ocular rehabilitation and the required interdisciplinary surgical and prosthetic treatment approach for rehabilitation of enucleated/eviscerated sockets with compromised implant situations, to provide a critical appraisal, and to present a simplified management strategy. © 2015 by the American College of Prosthodontists.

  18. PROSTHETIC MICROVENOUS GRAFTING IN THE RAT FEMORAL VEIN

    NARCIS (Netherlands)

    VANDERLEI, B; ROBINSON, PH; Bartels, H.

    Male Wistar rats were used to evaluate microvenous prosthetic grafting techniques and microvenous prostheses in the femoral vein. With the end-to-end technique to implant microvenous prostheses, there was extensive exposure of vessel wall collagen especially at the suture sites. Thrombus formation

  19. Prosthetic Hand For Holding Rods, Tools, And Handles

    Science.gov (United States)

    Belcher, Jewell G., Jr.; Vest, Thomas W.

    1995-01-01

    Prosthetic hand with quick-grip/quick-release lever broadens range of specialized functions available to lower-arm amputee by providing improved capabilities for gripping rods, tools, handles, and like. Includes two stationary lower fingers opposed by one pivoting upper finger. Lever operates in conjunction with attached bracket.

  20. Enhanced visual feedback for slip prevention with a prosthetic hand.

    Science.gov (United States)

    Engeberg, Erik D; Meek, Sanford

    2012-12-01

    Upper limb amputees have no direct sense of the grip force applied by a prosthetic hand; thus, precise control of the applied grip force is difficult for amputees. Since there is little object deformation when rigid objects are grasped, it is difficult for amputees to visually gauge the applied grip force in this situation. To determine if the applied grip force from a prosthetic hand can be visually displayed and used to more efficaciously grasp objects. Experimental controlled trial. Force feedback is used in the control algorithm for the prosthetic hand and supplied visually to the user through a bicolor LED experimentally mounted to the thumb. Several experiments are performed by able-bodied test subjects to rate the usefulness of the additional visual feedback when manipulating a clearly visible, brittle object that can break if grasped too firmly. A hybrid force-velocity sliding mode controller is used with and without additional visual force feedback supplied to the operators. Subjective evaluations and success rates from the test subjects indicate a statistically significant reduction in breaking the grasped object when using the prosthesis with the extra visual feedback. The additional visual force feedback can effectively facilitate the manipulation of brittle objects. Clinical relevance The novel approach of this research is the implementation of a noninvasive, effective and economic technique to visually indicate the grip force applied by a prosthetic hand to upper limb amputees. This technique provides a statistically significant improvement when handling brittle objects.

  1. Development of a prototype over-actuated biomimetic prosthetic hand.

    Science.gov (United States)

    Williams, Matthew R; Walter, Wayne

    2015-01-01

    The loss of a hand can greatly affect quality of life. A prosthetic device that can mimic normal hand function is very important to physical and mental recuperation after hand amputation, but the currently available prosthetics do not fully meet the needs of the amputee community. Most prosthetic hands are not dexterous enough to grasp a variety of shaped objects, and those that are tend to be heavy, leading to discomfort while wearing the device. In order to attempt to better simulate human hand function, a dexterous hand was developed that uses an over-actuated mechanism to form grasp shape using intrinsic joint mounted motors in addition to a finger tendon to produce large flexion force for a tight grip. This novel actuation method allows the hand to use small actuators for grip shape formation, and the tendon to produce high grip strength. The hand was capable of producing fingertip flexion force suitable for most activities of daily living. In addition, it was able to produce a range of grasp shapes with natural, independent finger motion, and appearance similar to that of a human hand. The hand also had a mass distribution more similar to a natural forearm and hand compared to contemporary prosthetics due to the more proximal location of the heavier components of the system. This paper describes the design of the hand and controller, as well as the test results.

  2. Prosthetic rehabilitation of a patient with a resected right ...

    African Journals Online (AJOL)

    2015-10-01

    Oct 1, 2015 ... [3] In literature, a mandibular or palatal prosthesis with a guide ramp is one of the methods for reducing mandibular deviation.[1,2,6]. This report describes the implant‑supported prosthetic treatment of a patient with a palatinal guidance ramp‑positioning apparatus after mandibular resection caused by an ...

  3. ORIGINAL ARTICLE Prosthetic management of an 11-year-old ...

    African Journals Online (AJOL)

    Ogunbodede

    Hickey A.J., Vergo T.J. Prothetic treatments for patients with ectodermal dysplasia J. Prosthet. Dent 2001; 86(4):364-368. 13. Bergendral. B. Prothetic habilitation of a young patient with hypohidrotic ectodermal dysplasia and oligodontia: a case report of 20 years of treatment. Int J Prosthodont 2001; 14(5). 471-479. 14.

  4. Consumer satisfaction with the services of prosthetics and orthotics facilities

    NARCIS (Netherlands)

    Bosmans, Joline; Geertzen, Jan; Dijkstra, Pieter U.

    2009-01-01

    Consumer satisfaction with the services provided in a prosthetics and orthotics (PO) facility has seldom been studied. The aim of this study was to analyze consumer satisfaction regarding the services provided by 15 PO facilities in The Netherlands. Consumers (n=1,364) of these PO facilities who

  5. Laser photonics application in prosthetic dentistry for denture design optimization

    Science.gov (United States)

    Grosmann, M. H.; Kiryushin, M. A.; Larkin, A. I.; Lebedenko, A. I.; Lebedenko, I. Yu.; Lopatina, N. A.; Osincev, A. V.; Shchepinov, V. P.; Shchepinova, I. V.

    2010-06-01

    The aim of this work is to demonstrate that holographic and speckle interferometry—laser photonics methods are compatible and useful for prosthetic stomatology. These methods allow to study the deformation of the mandible after insertion of mini-implants of various forms, and to give the practical medical recommendations.

  6. Development of a 3D-Printed Robotic Prosthetic Arm

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Martinez, M.; Garcia-Miquel, A.; Vidal Martinez, N.

    2016-07-01

    Current prostheses are not affordable to the general public. 3D printing technology may allow low-cost production of such devices, making them more readily accessible to people in need. This contribution presents the set-up and the considerations that have to be taken into account to develop a functional artificial upper limb prototype. The robotic prosthetic arm reported herein was produced entirely using 3D printing technology to demonstrate its feasibility on a limited budget. The project was developed to integrate two different functional modes: a prosthetic application and a remote application. The prosthetic application is intended to emulate existing prosthetic devices using myoelectric sensors. The remote application is conceived as a tool for prevention, by providing the general public with a device that could carry out activities that entail a risk of severe physical injury. This is achieved using a hand-tracking system that allows the robotic arm to copy the user’s movements remotely and in real time. The outcome of the validation tests has been considerably successful for both applications and the total costs are on target. (Author)

  7. Prosthetic valve endocarditis after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; De Backer, Ole; Thyregod, Hans G H

    2015-01-01

    BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an advancing mode of treatment for inoperable or high-risk patients with aortic stenosis. Prosthetic valve endocarditis (PVE) after TAVI is a serious complication, but only limited data exist on its incidence, outcome, and procedural...

  8. Increased Mortality After Prosthetic Joint Infection in Primary THA

    DEFF Research Database (Denmark)

    Gundtoft, Per Hviid; Pedersen, Alma Becic; Varnum, Claus

    2017-01-01

    Background: Revision for prosthetic joint infection (PJI) has a major effect on patients’ health but it remains unclear if early PJI after primary THA is associated with a high mortality. Questions/Purposes: (1) Do patients with a revision for PJI within 1 year of primary THA have increased...

  9. Specialisation and specialist education in prosthetic dentistry in Europe

    NARCIS (Netherlands)

    Owall, B.; Welfare, R.; Garefis, P.; Hedzelek, W.; Hobkirk, J.; Isidor, F.; Jerolimov, V.; Jokstad, A.; Kalk, W.; Kronstrom, M.; van der Kuij, P.; Mericske-Stern, R.; Naert, I.; Narhi, T.; Nilner, K.; Polyzois, G.; Setz, J.; User, A.; Zonnenberg, A.

    2006-01-01

    This presentation reports on the results of a meeting of prosthodontists from selected European countries. The aim of the meeting was to analyse and promote specialisation and specialist education in Prosthetic Dentistry in Europe. Representatives for Europe were selected from the European

  10. Selective criteria for successful long-term prosthetic use.

    Science.gov (United States)

    Mueller, M J; Delitto, A

    1985-07-01

    The purpose of this study was to identify criteria contributing to successful long-term prosthetic use in patients with an amputation secondary to vascular disease. All elderly patients with a unilateral below-knee amputation or an above-knee amputation, secondary to vascular disease, seen in our clinic between 1977 and 1982 were included in this telephone survey. Of those contacted, 37 of 38 below-knee amputees (BKAs) and 7 of 18 above-knee amputees (AKAs) still wore their prostheses at least part of every day (success). We used a two-tailed chi-square to compare the success of the BKAs with the success of the AKAs. The BKAs were successful more often (X2 = 24.81, df = 1, p less than .001). All AKAs also were characterized according to age, time from prescription, obesity, ambulatory status, strength, range of motion, sex, general compliance, and medical problems after prosthetic prescription. Of these criteria, only compliance and medical problems after prescription showed a significant difference between successful and nonsuccessful long-term AKA prosthetic users (X2 = 5.76, df = 1, p less than .05 for each criterion). As the demands of quality assurance and diagnostic related groupings increase, these results can assist the physical therapy clinician in setting realistic goals for the geriatric amputee and help predict if the patient will be a successful prosthetic user.

  11. Development of a prototype over-actuated biomimetic prosthetic hand.

    Directory of Open Access Journals (Sweden)

    Matthew R Williams

    Full Text Available The loss of a hand can greatly affect quality of life. A prosthetic device that can mimic normal hand function is very important to physical and mental recuperation after hand amputation, but the currently available prosthetics do not fully meet the needs of the amputee community. Most prosthetic hands are not dexterous enough to grasp a variety of shaped objects, and those that are tend to be heavy, leading to discomfort while wearing the device. In order to attempt to better simulate human hand function, a dexterous hand was developed that uses an over-actuated mechanism to form grasp shape using intrinsic joint mounted motors in addition to a finger tendon to produce large flexion force for a tight grip. This novel actuation method allows the hand to use small actuators for grip shape formation, and the tendon to produce high grip strength. The hand was capable of producing fingertip flexion force suitable for most activities of daily living. In addition, it was able to produce a range of grasp shapes with natural, independent finger motion, and appearance similar to that of a human hand. The hand also had a mass distribution more similar to a natural forearm and hand compared to contemporary prosthetics due to the more proximal location of the heavier components of the system. This paper describes the design of the hand and controller, as well as the test results.

  12. Diagnostic flowcharts in osteomyelitis, spondylodiscitis and prosthetic joint infection

    NARCIS (Netherlands)

    Jutte, P.; Lazzeri, E.; Sconfienza, L. M.; Cassar-Pullicino, V.; Trampuz, A.; Petrosillo, N.; Signore, A.

    Infections of the bone, spine and prosthetic joints are serious and complex conditions to diagnose and to treat. Structured diagnostic workup may very well improve the accuracy and speed of diagnosis, thereby improving the outcome since treatment may very well be more successful and less harmful if

  13. Prosthetic prescription in the Netherlands : an observational study

    NARCIS (Netherlands)

    van der Linde, H; Geertzen, JHB; Hofstad, CJ; Postema, K; Van Limbeek, Jacques

    2003-01-01

    Prosthetic prescription for lower limb amputees and the methodology used are primarily based on empirical knowledge. Clinical expertise plays an important role that can lead to an adequate prescription; however, a clear evidence based motivation for the choices made cannot be given. This can lead to

  14. Determining asymmetry of roll-over shapes in prosthetic walking

    NARCIS (Netherlands)

    Curtze, C.; Otten, Bert; Hof, A.L.; Postema, K.

    2011-01-01

    How does the inherent asymmetry of the locomotor system in people with lower-limb amputation affect the ankle-foot roll-over shape of prosthetic walking? In a single-case design, we evaluated the walking patterns of six people with lower-limb amputation (3 transtibial and 3 transfemoral) and three

  15. Renal Haemosiderosis in Patients with· Prosthetic Heart Valves

    African Journals Online (AJOL)

    1974-04-13

    Apr 13, 1974 ... Prosthetic Heart Valves. A. G. ROSE. SUMMARY. Renal haemosiderosis is the anatomical indicator of intra- vascular haemolysis. The incidence of renal haemosiderosis was studied in 66 patients with valve prostheses, 32 patients with advanced rheumatic-type valvular deformities and in 21 consecutive ...

  16. ORIGINAL ARTICLE Prosthetic management of an 11-year-old ...

    African Journals Online (AJOL)

    Ogunbodede

    Result: Upper removable partial denture and lower removable complete denture was fabricated and fitted satisfactory. Conclusion: The psychological and social embarrassment suffered by children with ectodermal dysplasia associated with missing teeth can be greatly improved with early prosthetic rehabilitation with ...

  17. Fabrication, sensation and control of fluidic elastomer actuators and their application towards hand orthotics and prosthetics

    Science.gov (United States)

    Zhao, Huichan

    Due to their continuous and natural motion, fluidic elastomer actuators (FEAs) have shown potential in a range of robotic applications including prosthetics and orthotics. Despite their advantages and rapid developments, robots using these actuators still have several challenging issues to be addressed. First, the reliable production of low cost and complex actuators that can apply high forces is necessary, yet none of existing fabrication methods are both easy to implement and of high force output. Next, compliant or stretchable sensors that can be embedded into their bodies for sophisticated functions are required, however, many of these sensors suffer from hysteresis, fabrication complexity, chemical safety and environmental instability, and material incompatibility with soft actuators. Finally, feedback control for FEAs is necessary to achieve better performance, but most soft robots are still "open-loop". In this dissertation, I intend to help solve the above issues and drive the applications of soft robotics towards hand orthotics and prosthetics. First, I adapt rotational casting as a new manufacturing method for soft actuators. I present a cuboid soft actuator that can generate a force of >25 N at its tip, a near ten-fold increase over similar actuators previously reported. Next, I propose a soft orthotic finger with position control enabled via embedded optical fiber. I monitor both the static and dynamic states via the optical sensor and achieve the prescribed curvatures accurately and with stability by a gain-scheduled proportional-integral-derivative controller. Then I develop the soft orthotic fingers into a low-cost, closed-loop controlled, soft orthotic glove that can be worn by a typical human hand and helpful for grasping light objects, while also providing finger position control. I achieve motion control with inexpensive, binary pneumatic switches controlled by a simple finite-state-machine. Finally, I report the first use of stretchable optical

  18. Evaluation of 3D printed anatomically scalable transfemoral prosthetic knee.

    Science.gov (United States)

    Ramakrishnan, Tyagi; Schlafly, Millicent; Reed, Kyle B

    2017-07-01

    This case study compares a transfemoral amputee's gait while using the existing Ossur Total Knee 2000 and our novel 3D printed anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee is 3D printed out of a carbon-fiber and nylon composite that has a gear-mesh coupling with a hard-stop weight-actuated locking mechanism aided by a cross-linked four-bar spring mechanism. This design can be scaled using anatomical dimensions of a human femur and tibia to have a unique fit for each user. The transfemoral amputee who was tested is high functioning and walked on the Computer Assisted Rehabilitation Environment (CAREN) at a self-selected pace. The motion capture and force data that was collected showed that there were distinct differences in the gait dynamics. The data was used to perform the Combined Gait Asymmetry Metric (CGAM), where the scores revealed that the overall asymmetry of the gait on the Ossur Total Knee was more asymmetric than the anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee had higher peak knee flexion that caused a large step time asymmetry. This made walking on the anatomically scalable transfemoral prosthetic knee more strenuous due to the compensatory movements in adapting to the different dynamics. This can be overcome by tuning the cross-linked spring mechanism to emulate the dynamics of the subject better. The subject stated that the knee would be good for daily use and has the potential to be adapted as a running knee.

  19. 78 FR 3883 - The Bon-Ton Stores, Inc., Provisional Acceptance of a Settlement Agreement and Order

    Science.gov (United States)

    2013-01-17

    ... drawstrings (Garments) to consumers. The Garments were sold at retail stores in the United States for between... COMMISSION The Bon-Ton Stores, Inc., Provisional Acceptance of a Settlement Agreement and Order AGENCY... Agreement with The Bon-Ton Stores, Inc., containing a civil penalty of $450,000.00, within twenty (20) days...

  20. Innovative approach to computer-guided surgery and fixed provisionalization assisted by screw-retained transitional implants.

    Science.gov (United States)

    Gallucci, German O; Finelle, Gary; Papadimitriou, Dimitrios E V; Lee, Sang J

    2015-01-01

    The objectives of this case series are to describe a novel clinical approach to treat completely edentulous patients and determine its viability. Computer-guided implant planning was used to create a screw-retained surgical template (ST) supported by transitional implants and a fixed screw-retained provisional prosthesis supported by the transitional implants at the time of definitive implant placement. Five patients with at least one edentulous arch were treated. After the diagnostic tooth setup was performed, a duplicate with radiopaque acrylic resin was fabricated to serve as a surgical template (ST) for the placement of screw-form transitional implants and a radiographic guide (RG). Four transitional implants were strategically placed through the guide where they would not interfere with the future definitive implants. The transitional implants were used to support the RG during computed tomographic scanning. Subsequently, the RG was converted into a second ST based on three-dimensional virtual planning. Eight implants were placed by the computer-guided system, and an immediate prefabricated fixed provisional was connected to the transitional implants. All the implants included in the study achieved primary stability and osseointegrated successfully. For 4 months, the transitional implants served successfully as abutments for the provisional prosthesis. This innovative clinical approach overcomes the limitations of a mucosa/bone-supported ST by offering fixed, reproducible support for the RG and ST by means of transitional implants. The delivery of a prefabricated screw-retained provisional on transitional implants allows for passive healing and minimum chairside adjustments.

  1. 76 FR 77981 - Build-A-Bear Workshop, Inc., Provisional Acceptance of a Settlement Agreement and Order

    Science.gov (United States)

    2011-12-15

    ... COMMISSION Build-A-Bear Workshop, Inc., Provisional Acceptance of a Settlement Agreement and Order AGENCY... Agreement with Build-A-Bear Workshop, Inc., containing a civil penalty of $600,000.00. DATES: Any interested... Agreement 1. In accordance with 16 CFR 1118.20, Build-A-Bear Workshop, Inc. (``Build-A-Bear'') and staff of...

  2. Immediate loading versus immediate provisionalization of maxillary single-tooth replacements: a prospective randomized study with BioComp implants

    NARCIS (Netherlands)

    Lindeboom, Jerome A.; Frenken, Joost W.; Dubois, Leander; Frank, Michael; Abbink, Ingmar; Kroon, Frans H.

    2006-01-01

    PURPOSE: The aim of this prospective randomized study was to evaluate the clinical outcome of immediately loaded solid plasma sprayed (TPS) BioComp (BioComp Industries BV, Vught, The Netherlands) implants versus immediate provisionalized but non-loaded BioComp implants in the anterior and premolar

  3. Investigation on the hematopoietic effect of functional foods using radiation and preparing the provisional product

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Ho; Oh, Heon; Lee, Song Eun; Jeong, Yong Woon [Chonnam National University, Kwangju (Korea)

    1999-04-01

    We performed this study to determine the effect of several oriental prescriptions as energy tonic (Chinese medical concept: Bu-Qi) or blood building (Chinese medical concept: Bu-Xie) decoction and its major ingredients on jejunal crypt survival, endogenous spleen colony formation, and apoptosis in jejunal crypt cells of mice irradiated with high and low dose of gamma-irradiation. For the study of evaluation on the biological stability of irradiated chinese medical prescriptions, we performed the experiment to determine the effect of irradiated (10kGy) or unirradiated Si-Wu-Tang, Bu-Zhong-Yi-Qi-Tang and San-Ling-Bai-Shu-San in irradiated mice. Further studies are needed to characterize better the protective nature of the total extract and its ingredients and for preparing the provisional product. (author). 61 refs., 3 figs., 21 tabs.

  4. Upper lower Cambrian (provisional Cambrian Series 2 trilobites from northwestern Gansu Province, China

    Directory of Open Access Journals (Sweden)

    Jan Bergström†

    2014-08-01

    Full Text Available Upper lower Cambrian (provisional Cambrian Series 2 trilobites are described from three sections through the Shuangyingshan Formation in the Beishan area, northwestern Gansu Province, China. The trilobite fauna is dominated by eodiscoid and corynexochid trilobites, together representing at least ten genera: Serrodiscus, Tannudiscus, Calodiscus, Pagetides, Kootenia, Edelsteinaspis, Ptarmiganoides?, Politinella, Dinesus and Subeia. Eleven species are described, of which seven are identified with previously described taxa and four described under open nomenclature. The composition of the fauna suggests biogeographic affinity with Siberian rather than Gondwanan trilobite faunas, and the Cambrian Series 2 faunas described herein and from elsewhere in northwestern China seem to be indicative of the marginal areas of the Siberian palaeocontinent. This suggests that the Middle Tianshan–Beishan Terrane may have been located fairly close to Siberia during middle–late Cambrian Epoch 2.

  5. Pre-surgical Provisional Prosthesis for Immediate Non-occlusal-loaded Flapless Implant.

    Science.gov (United States)

    Inbarajan, Athiban; Banu, Fathima; Tv, Padmanabhan; Kumar, Anand; Seenivasan, Madhan

    2017-06-13

    A 49-year-old patient reported for immediate replacement of missing maxillary anterior teeth with implant-retained prosthesis. Elevation of flap alters the mucosal level, causes discomfort, and delays the restorative procedure. To maintain the esthetics, flapless surgery was planned. Since placement of an implant is pre-planned in a predetermined site, fabrication of the prostheses before commencement of the surgery, especially when replacing the teeth in the anterior region, could be a viable option. This case report explains the method of fabrication of the provisional restoration for flapless surgery in the presurgical phase. The technique would avoid any micromotion and implant instability caused due to abutment preparation and impression procedure postsurgically.

  6. Emergency department external fixation for provisional treatment of pilon and unstable ankle fractures

    Directory of Open Access Journals (Sweden)

    Craig R Lareau

    2015-01-01

    Full Text Available Unstable ankle fractures and impacted tibial pilon fractures often benefit from provisional external fixation as a temporizing measure prior to definitive fixation. Benefits of external fixation include improved articular alignment, decreased articular impaction, and soft tissue rest. Uniplanar external fixator placement in the Emergency Department (ED ex-fix is a reliable and safe technique for achieving ankle reduction and stability while awaiting definitive fixation. This procedure involves placing transverse proximal tibial and calcaneal traction pins and connecting the pins with two external fixator rods. This technique is particularly useful in austere environments or when the operating room is not immediately available. Additionally, this bedside intervention prevents the patient from requiring general anesthesia and may be a cost-effective strategy for decreasing valuable operating time. The ED ex-fix is an especially valuable procedure in busy trauma centers and during mass casualty events, in which resources may be limited.

  7. Dutch evidence-based guidelines for amputation and prosthetics of the lower extremity : Rehabilitation process and prosthetics. Part 2

    NARCIS (Netherlands)

    Geertzen, Jan; van der Linde, Harmen; Rosenbrand, Kitty; Conradi, Marcel; Deckers, Jos; Koning, Jan; Rietman, Hans S.; van der Schaaf, Dick; van der Ploeg, Rein; Schapendonk, Johannes; Schrier, Ernst; Duijzentkunst, Rob Smit; Spruit-van Eijk, Monica; Versteegen, Gerbrig; Voesten, Harrie

    2015-01-01

    Background: A structured, multidisciplinary approach in the rehabilitation process after amputation is needed that includes a greater focus on the involvement of both (para)medics and prosthetists. There is considerable variation in prosthetic prescription concerning the moment of initial prosthesis

  8. Workplace exposure to nanoparticles and the application of provisional nanoreference values in times of uncertain risks

    Science.gov (United States)

    van Broekhuizen, Pieter; van Broekhuizen, Fleur; Cornelissen, Ralf; Reijnders, Lucas

    2012-03-01

    Nano reference values (NRVs) for occupational use of nanomaterials were tested as provisional substitute for Occupational Exposure Limits (OELs). NRVs can be used as provisional limit values until Health-Based OELs or derived no-effect levels (DNEL) become available. NRVs were defined for 8 h periods (time weighted average) and for short-term exposure periods (15 min-time weighted average). To assess the usefulness of these NRVs, airborne number concentrations of nanoparticles (NPs) in the workplace environment were measured during paint manufacturing, electroplating, light equipment manufacturing, non-reflective glass production, production of pigment concentrates and car refinishing. Activities monitored were handling of solid engineered NPs (ENP), abrasion, spraying and heating during occupational use of nanomaterials (containing ENPs) and machining nanosurfaces. The measured concentrations are often presumed to contain ENPs as well as process-generated NPs (PGNP). The PGNP are found to be a significant source for potential exposure and cannot be ignored in risk assessment. Levels of NPs identified in workplace air were up to several millions of nanoparticles/cm3. Conventional components in paint manufacturing like CaCO3 and talc may contain a substantial amount of nanosized particulates giving rise to airborne nanoparticle concentrations. It is argued that risk assessments carried out for e.g. paint manufacturing processes using conventional non-nano components should take into account potential nanoparticle emissions as well. The concentrations measured were compared with particle-based NRVs and with mass-based values that have also been proposed for workers protection. It is concluded that NRVs can be used for risk management for handling or processing of nanomaterials at workplaces provided that the scope of NRVs is not limited to ENPs only, but extended to the exposure to process-generated NPs as well.

  9. In Vitro Fit and Cementation Resistance of Provisional Crowns for Single Implant-Supported Restorations.

    Science.gov (United States)

    Moris, Izabela Cristina Maurício; Oliveira, Juliana Elias de; Faria, Adriana Cláudia Lapria; Ribeiro, Ricardo Faria; Rodrigues, Renata Cristina Silveira

    2015-10-01

    This study aimed to verify marginal fit and the effect of cement film thickness standardization on retention of provisional crowns made with prefabricated acrylic cylinders on abutments, using two temporary luting agents subjected or not to mechanical cycling. Provisional crowns were made from bis-acryl (Luxatemp Fluorescence) or methyl methacrylate (Duralay) resins on acrylic cylinders and marginal fit and cement film thickness were evaluated. For retention evaluation, crowns were cemented with two temporary luting agents: non-eugenol zinc oxide (Tempbond NE) or calcium hydroxide-based (Hydcal) cements and subjected to tensile strength in a universal testing machine. After cleaning, debonded crowns were cemented again, subjected to mechanical cycling and retention was reassessed. The results of marginal fit and cement film thickness were analyzed by Student's t-test while retention of cements before and after mechanical cycling was analyzed using a mixed linear model. Methyl methacrylate crowns presented greater marginal misfit (p=0.001) and occlusal cement film thickness (p=0.003) than the bis-acryl ones. No difference was observed at axial cement film thickness (p=0.606). Resins (p=0.281) did not affect crown retention, but luting agents (p=0.029) and mechanical cycling (p=0.027) showed significant effects. The only significant interaction was mechanical cycling*luting agents, which means that luting agents were differently affected by mechanical cycling (p=0.002). In conclusion, the results showed that bis-acryl resin associated to calcium-hydroxide luting agent provided the best retention and lower cement thickness.

  10. Agitation in cognitive disorders: International Psychogeriatric Association provisional consensus clinical and research definition.

    Science.gov (United States)

    Cummings, Jeffrey; Mintzer, Jacobo; Brodaty, Henry; Sano, Mary; Banerjee, Sube; Devanand, D P; Gauthier, Serge; Howard, Robert; Lanctôt, Krista; Lyketsos, Constantine G; Peskind, Elaine; Porsteinsson, Anton P; Reich, Edgardo; Sampaio, Cristina; Steffens, David; Wortmann, Marc; Zhong, Kate

    2015-01-01

    Agitation is common across neuropsychiatric disorders and contributes to disability, institutionalization, and diminished quality of life for patients and their caregivers. There is no consensus definition of agitation and no widespread agreement on what elements should be included in the syndrome. The International Psychogeriatric Association formed an Agitation Definition Work Group (ADWG) to develop a provisional consensus definition of agitation in patients with cognitive disorders that can be applied in epidemiologic, non-interventional clinical, pharmacologic, non-pharmacologic interventional, and neurobiological studies. A consensus definition will facilitate communication and cross-study comparison and may have regulatory applications in drug development programs. The ADWG developed a transparent process using a combination of electronic, face-to-face, and survey-based strategies to develop a consensus based on agreement of a majority of participants. Nine-hundred twenty-eight respondents participated in the different phases of the process. Agitation was defined broadly as: (1) occurring in patients with a cognitive impairment or dementia syndrome; (2) exhibiting behavior consistent with emotional distress; (3) manifesting excessive motor activity, verbal aggression, or physical aggression; and (4) evidencing behaviors that cause excess disability and are not solely attributable to another disorder (psychiatric, medical, or substance-related). A majority of the respondents rated all surveyed elements of the definition as "strongly agree" or "somewhat agree" (68-88% across elements). A majority of the respondents agreed that the definition is appropriate for clinical and research applications. A provisional consensus definition of agitation has been developed. This definition can be used to advance interventional and non-interventional research of agitation in patients with cognitive impairment.

  11. Effects of prosthetic foot forefoot flexibility on gait of unilateral transtibial prosthesis users.

    Science.gov (United States)

    Klodd, Elizabeth; Hansen, Andrew; Fatone, Stefania; Edwards, Mark

    2010-01-01

    Five solid-ankle experimental prosthetic feet were used in this double-blind randomized crossover study to determine the effects of forefoot flexibility on gait of 14 unilateral transtibial prosthesis users. Flexibility in experimental feet was altered by changing the number of flexural hinges in their forefoot sections. When experimental prosthetic foot conditions were compared, measured prosthetic ankle dorsiflexion range of motion increased as much as 3.3° with increasing flexibility (p prosthetic ankle moments as high as 0.53 Nm/kg in late stance phase of walking as flexibility decreased (p prosthetic sides increased as much as 9% of body weight when subjects used the foot with the greatest flexibility (p = 0.001). The results of this study suggest solid-ankle prosthetic foot designs with overly flexible forefoot sections can cause a "drop-off" effect in late stance phase and during the transition of loading between prosthetic and contralateral limbs.

  12. A CLINICAL STUDY ON THE PERIODONTAL-IMPLANTO-PROSTHETIC REHABILITATION IN PATIENTS WITH PERIODONTAL DISEASES

    Directory of Open Access Journals (Sweden)

    Diana RADU-GHICA

    2012-06-01

    Full Text Available Scope of the study: A comparative analysis on the reliability of the methods of oral rehabilitation of partial edentation through fixed prostheses on dental support vs. prostheses on implants in patients with periodontal diseases. Materials and method: The experimental group was formed of 56 patients (25 men and 31 women, with ages between 23 and 68 years, and different classes of partial edentation in patients with a periodontopathed field. Mention should be made of the fact that, in the case of terminal edentations, a corresponding number of implants has been used, so that to reduce, as much as possible, the number of intermediates involved in the bridge bodies entering the structure of the prosthetic works with dental-implantary support. Results: The survival ratio for the implants substituting the periodontally-induced dental losses was of 90.5%, while that of the implants for the replacement of the teeth lost from other causes (caries, fractures, traumatisms was of 96.5%. Conclusions: The present study supports the assertion that, if the specific conditions of the clinical case under discussion permit it, fixed prosthesizing on a mixed implanto-dental support is more indicated, if considering that this type of prosthesis causes less negative modifications of the prosthetic field, comparatively with the partially-mobile one.

  13. STUDENTS' SELF-ASSESSMENT IN PRE-CLINICAL AND CLINICAL EDUCATION OF PROSTHETIC DENTISTRY

    Directory of Open Access Journals (Sweden)

    Dimiter Kirov

    2014-09-01

    Full Text Available Background: The ability to self-assess is a critical skill that all health professionals must be able to do, in order to achieve competence. This is essential for the doctors of dental medicine. During their education and practice they apply different clinical and para-clinical procedures. The aim is to evaluate the students' self-assessment skills during the education of clinic and pre-clinic of prosthetic dentistry. Material and methods: After the completion of certain work - preparation for full veneer crown, a questionnaire was provided to each student in preclinical course (n=30 and clinical course (n=30 for self-evaluation. The questionnaire involved: axial reduction, occlusal reduction, facial and lingual reduction, smoothing and finishing. The answers were based on the standard for the university grading scale. Than, the same questionnaire was fulfilled by the assistant professor without seeing students' self-evaluation. Results and Discussion: Results have been reported in percentages. 100% respond rate has been achieved. The students from the preclinical course tend to overestimate their performance (50%. The students from the clinical course tend to submit overall lower grades than the faculty evaluation (25%. Conclusions: The students from clinics have better self-assessment skills. The discrepancy was most pronounced in the junior students. The different evaluations (self-assessment and assistant professor's help students to improve their understanding of certain principles and improve the teaching effectiveness of education of prosthetic dentistry.

  14. [Study concerning the influence of the casting parameters of dental alloys on the cast prosthetic rehabilitation].

    Science.gov (United States)

    Viţalariu, Anca Mihaela; Tatarciuc, Monica Silvia

    2008-01-01

    The integration of a cast rehabilitation into the oral environment and its clinical longevity are mainly determined by the accuracy reproduction of the technological parameters. The aim of this study was to evaluate the structural defects induced by the modification of the technological conditions of casting the conventional and titanium alloys. We used 35 cast prosthetic rehabilitation, divided into 7 groups. For each group we modified one parameter: the width of the wax pattern, the design and topography of the casting channels, the absence of the cleanliness of the wax pattern, the preparation of the investment material, the thermal system for the mold preparation and reduced quantity of metal used for casting. For the 7-th group, represented by titanium cast rehabilitation, we modified the design and dimensions of the casting channels. The changes in the technological conditions induced porosity, incomplete frameworks or plus on the prosthetic appliances. The fundamental theoretical knowledge of the clinician and dental technician and the strictly application of the technologies assure the premises of the satisfaction of the patient.

  15. Systematic review of effects of current transtibial prosthetic socket designs-Part 1: Qualitative outcomes.

    Science.gov (United States)

    Safari, Mohammad Reza; Meier, Margrit Regula

    2015-01-01

    This review is an attempt to untangle the complexity of transtibial prosthetic socket fit, determine the most important characteristic for a successful fitting, and perhaps find some indication of whether a particular prosthetic socket type might be best for a given situation. Further, it is intended to provide directions for future research. We followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines and used medical subject headings and standard key words to search for articles in relevant databases. No restrictions were made on study design or type of outcome measure. From the obtained search results (n = 1,863), 35 articles were included. The relevant data were entered into a predefined data form that incorporated the Downs and Black risk of bias assessment checklist. Results for the qualitative outcomes (n = 19 articles) are synthesized. Total surface bearing sockets lead to greater activity levels and satisfaction in active persons with amputation, those with a traumatic cause of amputation, and younger persons with amputation than patellar tendon bearing sockets. Evidence on vacuum-assisted suction and hydrostatic sockets is inadequate, and further studies are much needed. To improve the scientific basis for prescription, comparison of and correlation between mechanical properties of interface material, socket designs, user characteristics, and outcome measures should be conducted and reported in future studies.

  16. Lagrangian coherent structures and turbulence characteristics downstream of prosthetic aortic valves

    Science.gov (United States)

    de Tullio, Marco D.

    2015-11-01

    The flowfield through prosthetic heart valves is investigated by means of direct numerical simulations, considering the fully coupled fluid-structure interaction problem. Two different aortic valve models are modeled: a bileaflet mechanical and a biological one. In order to reveal fluid flow structures and to better understand the transport mechanics, Lagrangian coherent structures (LCS) are used. LCS are distinguished material surfaces that can be identified as boundaries to regions with dynamically distinct behavior, and are revealed as hypersurfaces that locally maximize the finite-time Lyapunov exponent (FTLE) fields. Post-processing the flow simulation data, first FTLE fields are calculated integrating dense meshes of Lagrangian particles backward in time, and then attracting LCS are extracted. A three-jet configuration is distinctive of bi-leaflet mechanical valves, with higher turbulent shear stresses immediately distal to the valve leaflets, while a jet-like flow emerges from the central orifice of bio-prosthetic valves, with high turbulent shear stresses occurring at the edge of the jet. Details of the numerical methodology along with a thorough analysis of the different flow structures developing during the cardiac cycle for the two configurations will be provided.

  17. Identification of critical zones in the flow through prosthetic heart valves

    Science.gov (United States)

    Lopez, A.; Ledesma, R.; Zenit, R.; Pulos, G.

    2008-11-01

    The hemodynamic properties of prosthetic heart valves can cause blood damage and platelet activation due to the non- physiological flow patterns. Blood recirculation and elevated shear stresses are believed to be responsible for these complications. The objective of this study is to identify and quantify the conditions for which recirculation and high stress zones appear. We have performed a comparative study between a mechanical monoleaflet and biological valve. In order to generate the flow conditions to test the prosthesis, we have built a hydraulic circuit which reproduces the human systemic circulation, on the basis of the Windkessel model. This model is based on an electrical analogy which consists of an arterial resistance and compliance. Using PIV 3D- Stereo measurements, taken downstream from the prosthetic heart valves, we have reconstructed the full phase-averaged tridimensional velocity field. Preliminary results show that critical zones are more prominent in mechanical prosthesis, indicating that valves made with bio-materials are less likely to produce blood trauma. This is in accordance with what is generally found in the literature.

  18. Prosthetic Need between Different Age and Gender ‎With Patient Attending College of Dentistry,Tikrit ‎University

    Directory of Open Access Journals (Sweden)

    Reem Ahmed Shihab‎

    2017-12-01

    Full Text Available Background: the most important factor that affects speak, mastication and aesthetics is tooth loss which in turn imitated on the quality of life. The goal of our research was to evaluate the prosthetic need in sample attending prosthetic department and compare between age and gender. Material and methods: A sample of 244 patients was randomly chosen for questionnaire in the (Removable Prosthodontics Clinic into College of Dentistry-Tikrit University. All subjects were divided in six groups according to their age and also divided according to gender. Intraoral examinations were performed and reasons for extraction were recorded. All statistic calculations were performed using SPSS 23 (Statistical Package for Social Sciences. Results: The total number of 244 patients was involved in this study: 165 (67.6% males and 79 (32.4% females. We found that the higher percentage of patients were in the age group of (20-29 for males which was (23%, 56 patient, while the higher female percentage was found in the age group of (40-49 which was 11.5% . Reasons for extraction recorded the higher percentage due to Caries for both males (75.2% & females (81 % as suspected. Conclusion:The number of patient attending prosthetic department male more than female. Dental caries were the principal cause for extractions in younger patients followed by periodontitis. Society needs more motivation about dental health and care.

  19. Designing prosthetic knee joints with bio-inspired bearing surfaces.

    Science.gov (United States)

    Qiu, Mingfeng; Chyr, Anthony; Sanders, Anthony P; Raeymaekers, Bart

    2014-09-01

    It has long been known that articular cartilage exhibits a surface microtexture with shallow indentations. By contrast, prosthetic joints consist of ultra-smooth bearing surfaces, the longevity of which does not reach that of natural cartilage. We show that adding a microtexture to the smooth femoral component of a prosthetic knee joint reduces friction by increasing the lubricant film thickness between the bearing surfaces of the knee. We have implemented an elastohydrodynamic lubrication model to optimize the geometry of the microtexture, while taking into account the deformation of the polyethylene tibial insert. We have manufactured several microtexture designs on a surrogate femoral component, and experimentally demonstrate that the microtexture reduces friction between the surrogate femoral component and tibial insert.

  20. Control of Prosthetic Hands via the Peripheral Nervous System.

    Science.gov (United States)

    Ciancio, Anna Lisa; Cordella, Francesca; Barone, Roberto; Romeo, Rocco Antonio; Bellingegni, Alberto Dellacasa; Sacchetti, Rinaldo; Davalli, Angelo; Di Pino, Giovanni; Ranieri, Federico; Di Lazzaro, Vincenzo; Guglielmelli, Eugenio; Zollo, Loredana

    2016-01-01

    This paper intends to provide a critical review of the literature on the technological issues on control and sensorization of hand prostheses interfacing with the Peripheral Nervous System (i.e., PNS), and their experimental validation on amputees. The study opens with an in-depth analysis of control solutions and sensorization features of research and commercially available prosthetic hands. Pros and cons of adopted technologies, signal processing techniques and motion control solutions are investigated. Special emphasis is then dedicated to the recent studies on the restoration of tactile perception in amputees through neural interfaces. The paper finally proposes a number of suggestions for designing the prosthetic system able to re-establish a bidirectional communication with the PNS and foster the prosthesis natural control.

  1. Grasping Pattern Recognition and Grasping Force Estimation For Prosthetic Hands

    Directory of Open Access Journals (Sweden)

    Zhang Bing-Ke

    2016-01-01

    Full Text Available Human’s movement can be decoded by surface electromyography (EMG, and the prosthetic hand can be controlled freely through EMG signal. This paper proposes a grasping pattern and force synchronized decoding method for prosthetic hands. Considering pattern recognition and force estimation simultaneously, this paper analyzes whether different muscle contraction levels affect pattern recognition and whether different grasping modes have impact on force estimation, then proposes two schemes to complete EMG simultaneously decoding. Experiments compare the accuracy of the two methods. The results show that there is no much difference between two methods in force estimation, the former’s accuracy of pattern recognition is a little higher than the latter.

  2. Backstepping and sliding mode control hybridized for a prosthetic hand.

    Science.gov (United States)

    Engeberg, Erik D; Meek, Sanford G

    2009-02-01

    Open loop and force controllers are compared experimentally with three robust parallel force-velocity controllers that are developed for a prosthetic hand. Robust sliding mode, backstepping, and hybrid sliding mode-backstepping (HSMBS) parallel force-velocity controllers are tested by ten able-bodied subjects. Results obtained with a myoelectrically controlled prosthesis indicate that all three robust controllers offer a statistically significant improvement over linear hand prosthesis control schemes. The robust controllers enable the human operators to more easily manipulate a delicate object. Bench top experiments combined with quantitative and qualitative evaluations from ten test subjects reveal the HSMBS controller to be the best choice to improve control of powered prosthetic hands.

  3. Control of prosthetic hands via the peripheral nervous system

    Directory of Open Access Journals (Sweden)

    Anna Lisa eCiancio

    2016-04-01

    Full Text Available This paper intends to provide a critical review of the literature on the technological issues on control and sensorization of hand prostheses interfacing with the Peripheral Nervous System (i.e. PNS, and their experimental validation on amputees. The study opens with an in-depth analysis of control solutions and sensorization features of research and commercially available prosthetic hands. Pros and cons of adopted technologies, signal processing techniques and motion control solutions are investigated. Special emphasis is then dedicated to the recent studies on the restoration of tactile perception in amputees through neural interfaces. The paper finally proposes a number of suggestions for designing the prosthetic system able to re-establish a bidirectional communication with the PNS and foster the prosthesis natural control.

  4. Control of Prosthetic Hands via the Peripheral Nervous System

    Science.gov (United States)

    Ciancio, Anna Lisa; Cordella, Francesca; Barone, Roberto; Romeo, Rocco Antonio; Bellingegni, Alberto Dellacasa; Sacchetti, Rinaldo; Davalli, Angelo; Di Pino, Giovanni; Ranieri, Federico; Di Lazzaro, Vincenzo; Guglielmelli, Eugenio; Zollo, Loredana

    2016-01-01

    This paper intends to provide a critical review of the literature on the technological issues on control and sensorization of hand prostheses interfacing with the Peripheral Nervous System (i.e., PNS), and their experimental validation on amputees. The study opens with an in-depth analysis of control solutions and sensorization features of research and commercially available prosthetic hands. Pros and cons of adopted technologies, signal processing techniques and motion control solutions are investigated. Special emphasis is then dedicated to the recent studies on the restoration of tactile perception in amputees through neural interfaces. The paper finally proposes a number of suggestions for designing the prosthetic system able to re-establish a bidirectional communication with the PNS and foster the prosthesis natural control. PMID:27092041

  5. Prosthetic Rehabilitation in Partially Edentulous Elders – A Case Report

    Science.gov (United States)

    PICOS, ALINA MONICA; DONCA, VALER; PICOS, ANDREI

    2014-01-01

    Complex treatment involving removable articulated to fixed prostheses is indicated in extended edentulous areas, which represent clinical conditions more frequently encountered in elderly patients. A number of aspects must be considered in elderly patients before starting the therapy: physical and mental condition, self-care capacity, time and cost of treatment, predictability. In institutionalized elders, suffering of systemic diseases, the therapy of choice should be the least invasive and able to restore function at an acceptable level. Active healthy elders can be beneficiaries of complex prosthetic treatments involving many long sessions and difficult treatments. We present a case of a 74 year-old male with extended maxillary edentulous areas, in whom a complex prosthetic treatment was performed. PMID:26528025

  6. Prosthetic Rehabilitation in Partially Edentulous Elders - A Case Report.

    Science.gov (United States)

    Picos, Alina Monica; Donca, Valer; Picos, Andrei

    2014-01-01

    Complex treatment involving removable articulated to fixed prostheses is indicated in extended edentulous areas, which represent clinical conditions more frequently encountered in elderly patients. A number of aspects must be considered in elderly patients before starting the therapy: physical and mental condition, self-care capacity, time and cost of treatment, predictability. In institutionalized elders, suffering of systemic diseases, the therapy of choice should be the least invasive and able to restore function at an acceptable level. Active healthy elders can be beneficiaries of complex prosthetic treatments involving many long sessions and difficult treatments. We present a case of a 74 year-old male with extended maxillary edentulous areas, in whom a complex prosthetic treatment was performed.

  7. Mechanical Prosthetic Valves and Pregnancy: A therapeutic dilemma of anticoagulation

    Directory of Open Access Journals (Sweden)

    Prashanth Panduranga

    2014-10-01

    Full Text Available Choosing the best anticoagulant therapy for a pregnant patient with a mechanical prosthetic valve is controversial and the published international guidelines contain no clear-cut consensus on the best approach. This is due to the fact that there is presently no anticoagulant which can reliably decrease thromboembolic events while avoiding damage to the fetus. Current treatments include either continuing oral warfarin or substituting warfarin for subcutaneous unfractionated heparin or low-molecular-weight heparin (LMWH in the first trimester (6–12 weeks or at any point throughout the pregnancy. However, LMWH, while widely-prescribed, requires close monitoring of the blood anti-factor Xa levels. Unfortunately, facilities for such monitoring are not universally available, such as within hospitals in developing countries. This review evaluates the leading international guidelines concerning anticoagulant therapy in pregnant patients with mechanical prosthetic valves as well as proposing a simplified guideline which may be more relevant to hospitals in this region.

  8. A survey of prosthetic eye wearers to investigate mucoid discharge.

    Science.gov (United States)

    Pine, Keith; Sloan, Brian; Stewart, Joanna; Jacobs, Robert J

    2012-01-01

    This study aimed to better understand the causes and treatments of mucoid discharge associated with prosthetic eye wear by reviewing the literature and surveying anophthalmic patients. An anonymous questionnaire was completed by 429 prosthetic eye wearers who used visual analog scales to self-measure their discharge experience for four discharge characteristics: frequency, color, volume, and viscosity. These characteristics were analyzed with age, ethnicity, years wearing a prosthesis, eye loss cause, removal and cleaning regimes, hand-washing behavior, age of current prosthesis, and professional repolishing regimes as explanatory variables. Eighteen ocularists' Web sites containing comments on the cause and treatment of discharge were surveyed. Associations were found between discharge frequency and cleaning regimes with more frequent cleaning accompanying more frequent discharge. Color was associated with years of wearing and age, with more years of wearing and older people having less colored discharge. Volume was associated with cleaning regimes with more frequent cleaners having more volume. Viscosity was associated with cleaning regimes and years of wearing with more frequent cleaning and shorter wearing time accompanying more viscous discharge. No associations were found between discharge characteristics and ethnicity, eye loss cause, hand washing, age of current prosthesis, or repolishing regimes. Forty-seven percent of ocularists' Web sites advised that discharge was caused by surface deposits on the prosthesis, 29% by excessive handling of the prosthesis, and 24% by other causes. A standardized treatment protocol for managing discharge is lacking. More frequent prosthesis removal and cleaning was associated with more severe discharge, but the direction of cause and effect has not been established. Professional repolishing regimes had limited impact on discharge experience. Further research into the socket's response to prosthetic eye wear, including the

  9. Control of Prosthetic Hands via the Peripheral Nervous System

    OpenAIRE

    Anna Lisa eCiancio; Francesca eCordella; Roberto eBarone; Rocco Antonio Romeo; Alberto eDellacasa Bellingegni; Rinaldo eSacchetti; Angelo eDavalli; Giovanni eDi Pino; Federico eRanieri; Vincenzo eDi Lazzaro; Eugenio eGuglielmelli; Loredana eZollo

    2016-01-01

    This paper intends to provide a critical review of the literature on the technological issues on control and sensorization of hand prostheses interfacing with the Peripheral Nervous System (i.e., PNS), and their experimental validation on amputees. The study opens with an in-depth analysis of control solutions and sensorization features of research and commercially available prosthetic hands. Pros and cons of adopted technologies, signal processing techniques and motion control solutions are ...

  10. Laser Science and its Applications in Prosthetic Rehabilitation

    OpenAIRE

    Gounder, Revathy; Gounder, Srinivasan

    2016-01-01

    The minimal invasive nature of lasers, with quick tissue response and healing has made them a very attractive technology in various fields of dentistry which serves as a tool to create a better result than ever before. The rapid development of lasers and their wavelengths with variety of applications on soft and hard tissues may continue to have major impact on the scope and practice in prosthetic dentistry. The purpose of this article is to make every clinician familiar with the fundamentals...

  11. Open aortic stent grafting and prosthetic bypass in a child.

    Science.gov (United States)

    Ono, Takashi; Midorikawa, Hirofumi; Morishima, Shigehiro; Takano, Takashi; Nakazawa, Makoto; Kudo, Yoshimichi

    2011-10-01

    Pseudoaneurysm is a major complication of percutaneous balloon angioplasty to treat recoarctation and restenosis after an interrupted aortic arch repair. Endovascular stent grafting to manage this complication has rarely been performed in children. We used a combination of open stent grafting and a prosthetic ascending aorta-to-descending aorta bypass to treat a pseudoaneurysm and ascending aorta stenosis in a 7-year-old child. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Indium-111 leukocyte localization in infected prosthetic graft

    Energy Technology Data Exchange (ETDEWEB)

    Purnell, G.L.; Walker, C.W.; Allison, J.W.; Dalrymple, G.V. (Univ. of Arkansas for Medical Sciences, Little Rock (USA))

    1990-08-01

    Infective endocarditis can be difficult to prove, even in the face of strong clinical suspicion. A case in which standard methods of diagnosis failed to demonstrate endocarditis in a patient with recurrent Staphylococcus aureus bacteremia and porcine aortic valve is reported. An In-111 labelled leukocyte SPECT study demonstrated uptake in the aortic root and leaflets, and autopsy demonstrated vegetations on the leaflets. In-111 may prove useful in demonstrating endocarditis in patients with prosthetic valve infection.

  13. Neural-Network Control Of Prosthetic And Robotic Hands

    Science.gov (United States)

    Buckley, Theresa M.

    1991-01-01

    Electronic neural networks proposed for use in controlling robotic and prosthetic hands and exoskeletal or glovelike electromechanical devices aiding intact but nonfunctional hands. Specific to patient, who activates grasping motion by voice command, by mechanical switch, or by myoelectric impulse. Patient retains higher-level control, while lower-level control provided by neural network analogous to that of miniature brain. During training, patient teaches miniature brain to perform specialized, anthropomorphic movements unique to himself or herself.

  14. Prosthetic rehabilitation for a patient with microstomia: a case report

    Directory of Open Access Journals (Sweden)

    Moslehifard E

    2011-04-01

    Full Text Available "nFabrication of dental prosthesis for patients with microstomia has long been a problem for dentists. Microstomia is defined as an abnormally small oral orifice. Prosthetic rehabilitation of microstomia patients presents difficulties at all stages, from the preliminary impressions to fabrication of prosthesis. This study described a method for making impressions for patients with limited opening of the oral cavity which the use of a full-size impression tray was not possible.

  15. Treatment of Prosthetic Valve Thrombosis: Current Evidence and Future Directions.

    Science.gov (United States)

    Biteker, Murat; Altun, Ibrahim; Basaran, Ozcan; Dogan, Volkan; Yildirim, Birdal; Ergun, Gokhan

    2015-12-01

    Prosthetic heart valve thrombosis (PVT) is a rare but serious complication with high morbidity and mortality. The optimal treatment of the PVT is controversial and depends on thrombus location and size, the patient's functional class, the risk of surgery or thrombolysis, and the clinician's experience. Although surgical therapy has been the traditional therapeutic approach, studies with low-dose and slow-infusion rates of thrombolytic agents have revealed excellent results. This article reviews the various treatment options in patient with PVT.

  16. Rotationplasty with Vascular Reconstruction for Prosthetic Knee Joint Infection

    OpenAIRE

    Masahide Fujiki; Shimpei Miyamoto; Fumihiko Nakatani; Akira Kawai; Minoru Sakuraba

    2015-01-01

    Rotationplasty is used most often as a function-preserving salvage procedure after resection of sarcomas of the lower extremity; however, it is also used after infection of prosthetic knee joints. Conventional vascular management during rotationplasty is to preserve and coil major vessels, but recently, transection and reanastomosis of the major vessels has been widely performed. However, there has been little discussion regarding the optimal vascular management of rotationplasty after infect...

  17. Prosthetic rehabilitation of a total laryngectomy patient

    Directory of Open Access Journals (Sweden)

    Pulkit Jain

    2015-01-01

    Full Text Available The fundamental objective in restoring a defect created after total laryngectomy with a custom made silicone prosthesis is to enable the patient to cope better with the difficult process of rehabilitation after a major surgery has been performed. A cosmetically acceptable prosthesis that reproduces the color and form and allows the patient to return to his/her accustomed lifestyle. A sequence of steps for construction of custom-made laryngeal prosthesis is outlined in this case report using the readily available materials and method which any prosthodontist can readily understand and deliver.

  18. Iodine-125 orbital brachytherapy with a prosthetic implant in situ.

    Science.gov (United States)

    Stannard, Clare; Maree, Gert; Munro, Roger; Lecuona, Karin; Sauerwein, Wolfgang

    2011-05-01

    Brachytherapy is one method of irradiating the orbit after enucleation of an eye with a malignant tumor that has a potential to recur. It consists of 6 trains of I-125 seeds placed around the periphery of the orbit, a shorter central train, and a metal disc, loaded with seeds, placed beneath the eyelids. The presence of a prosthetic orbital implant requires omission of the central train and adjustment of the activity of the seeds in the anterior orbit around the prosthesis. This is a retrospective review of the technical modifications and outcome of 12 patients treated in this manner: 6 with retinoblastoma, 5 with malignant melanoma, and 1 with an intraocular rhabdomyosarcoma. The median dose was 35.5 Gy in 73 hours for retinoblastoma and 56 Gy in 141 hours for malignant melanoma. Patients with retinoblastoma and rhabdomyosarcoma also received chemotherapy. The tubes can be placed satisfactorily around the prosthesis. The increased activity in the anterior half of the tubes produced comparable dose distributions. There have been no orbital recurrences, no extrusion of the prosthesis, and cosmesis is good. Insertion of a prosthetic implant at the time of enucleation greatly enhances the subsequent cosmetic appearance. This should be encouraged unless there is frank tumor in the orbit. Orbital brachytherapy without the central train continues to give excellent local control. The short treatment time and good cosmesis are added advantages. The patient is spared the expense and inconvenience of removing and replacing the prosthetic implant.

  19. Providing a sense of touch to prosthetic hands.

    Science.gov (United States)

    Nghiem, Bao Tram; Sando, Ian C; Gillespie, R Brent; McLaughlin, Bryan L; Gerling, Gregory J; Langhals, Nicholas B; Urbanchek, Melanie G; Cederna, Paul S

    2015-06-01

    Each year, approximately 185,000 Americans suffer the devastating loss of a limb. The effects of upper limb amputations are profound because a person's hands are tools for everyday functioning, expressive communication, and other uniquely human attributes. Despite the advancements in prosthetic technology, current upper limb prostheses are still limited in terms of complex motor control and sensory feedback. Sensory feedback is critical to restoring full functionality to amputated patients because it would relieve the cognitive burden of relying solely on visual input to monitor motor commands and provide tremendous psychological benefits. This article reviews the latest innovations in sensory feedback and argues in favor of peripheral nerve interfaces. First, the authors examine the structure of the peripheral nerve and its importance in the development of a sensory interface. Second, the authors discuss advancements in targeted muscle reinnervation and direct neural stimulation by means of intraneural electrodes. The authors then explore the future of prosthetic sensory feedback using innovative technologies for neural signaling, specifically, the sensory regenerative peripheral nerve interface and optogenetics. These breakthroughs pave the way for the development of a prosthetic limb with the ability to feel.

  20. Prosthetic design directives: Low-cost hands within reach.

    Science.gov (United States)

    Jones, G K; Rosendo, A; Stopforth, R

    2017-07-01

    Although three million people around the world suffer from the lack of one or both upper limbs 80% of this number is located within developing countries. While prosthetic prices soar with technology 3D printing and low cost electronics present a sensible solution for those that cannot afford expensive prosthetics. The electronic and control design of a low-cost prosthetic hand, the Touch Hand II, is discussed. This paper shows that sensorless techniques can be used to reduce design complexities, costs, and provide easier access to the electronics. A closing and opening finite state machine (COFSM) was developed to handle the actuated digit joint control state and a supervisory switching control scheme, used for speed and grip strength control. Three torque and speed settings were created to be preset for specific grasps. The hand was able to replicate ten frequently used grasps and grip some common objects. Future work is necessary to enable a user to control it with myoelectric signals (MESs) and to solve operational problems related to electromagnetic interference (EMI).

  1. Overview: Mechanism and Control of a Prosthetic Arm.

    Science.gov (United States)

    Kulkarni, Tushar; Uddanwadiker, Rashmi

    2015-09-01

    Continuous growth in industrialization and lack of awareness in safety parameters the cases of amputations are growing. The search of safer, simpler and automated prosthetic arms for managing upper limbs is expected. Continuous efforts have been made to design and develop prosthetic arms ranging from simple harness actuated to automated mechanisms with various control options. However due the cost constraints, the automated prosthetic arms are still out of the reach of needy people. Recent data have shown that there is a wide scope to develop a low cost and light weight upper limb prosthesis. This review summarizes the various designs methodologies, mechanisms and control system developed by the researchers and the advances therein. Educating the patient to develop acceptability to prosthesis and using the same for the most basic desired functions of human hand, post amputation care and to improve patient's independent life is equally important. In conclusion it can be interpreted that there is a wide scope in design in an adaptive mechanism for opening and closing of the fingers using other methods of path and position synthesis. Simple mechanisms and less parts may optimize the cost factor. Reduction in the weight of the prosthesis may be achieved using polymers used for engineering applications. Control system will remain never ending challenge for the researchers, but it is essential to maintain the simplicity from the patients perspective.

  2. Evaluation of new suspension system for limb prosthetics.

    Science.gov (United States)

    Gholizadeh, Hossein; Abu Osman, Noor Azuan; Eshraghi, Arezoo; Ali, Sadeeq; Arifin, Nooranida; Wan Abas, Wan Abu Bakar

    2014-01-10

    Good prosthetic suspension system secures the residual limb inside the prosthetic socket and enables easy donning and doffing. This study aimed to introduce, evaluate and compare a newly designed prosthetic suspension system (HOLO) with the current suspension systems (suction, pin/lock and magnetic systems). All the suspension systems were tested (tensile testing machine) in terms of the degree of the shear strength and the patient's comfort. Nine transtibial amputees participated in this study. The patients were asked to use four different suspension systems. Afterwards, each participant completed a questionnaire for each system to evaluate their comfort. Furthermore, the systems were compared in terms of the cost. The maximum tensile load that the new system could bear was 490 N (SD, 5.5) before the system failed. Pin/lock, magnetic and suction suspension systems could tolerate loads of 580 N (SD, 8.5), 350.9 (SD, 7) and 310 N (SD, 8.4), respectively. Our subjects were satisfied with the new hook and loop system, particularly in terms of easy donning and doffing. Furthermore, the new system is considerably cheaper (35 times) than the current locking systems in the market. The new suspension system could successfully retain the prosthesis on the residual limb as a good alternative for lower limb amputees. In addition, the new system addresses some problems of the existing systems and is more cost effective than its counterparts.

  3. Nuclear Medicine in Diagnosis of Prosthetic Valve Endocarditis: An Update

    Science.gov (United States)

    Musso, Maria; Petrosillo, Nicola

    2015-01-01

    Over the past decades cardiovascular disease management has been substantially improved by the increasing introduction of medical devices as prosthetic valves. The yearly rate of infective endocarditis (IE) in patient with a prosthetic valve is approximately 3 cases per 1,000 patients. The fatality rate of prosthetic valve endocarditis (PVE) remains stable over the years, in part due to the aging of the population. The diagnostic value of echocardiography in diagnosis is operator-dependent and its sensitivity can decrease in presence of intracardiac devices and valvular prosthesis. The modified Duke criteria are considered the gold standard for diagnosing IE; their sensibility is 80%, but in clinical practice their diagnostic accuracy in PVE is lower, resulting inconclusively in nearly 30% of cases. In the last years, these new imaging modalities have gained an increasing attention because they make it possible to diagnose an IE earlier than the structural alterations occurring. Several studies have been conducted in order to assess the diagnostic accuracy of various nuclear medicine techniques in diagnosis of PVE. We performed a review of the literature to assess the available evidence on the role of nuclear medicine techniques in the diagnosis of PVE. PMID:25695043

  4. A smartphone photogrammetry method for digitizing prosthetic socket interiors.

    Science.gov (United States)

    Hernandez, Amaia; Lemaire, Edward

    2017-04-01

    Prosthetic CAD/CAM systems require accurate 3D limb models; however, difficulties arise when working from the person's socket since current 3D scanners have difficulties scanning socket interiors. While dedicated scanners exist, they are expensive and the cost may be prohibitive for a limited number of scans per year. A low-cost and accessible photogrammetry method for socket interior digitization is proposed, using a smartphone camera and cloud-based photogrammetry services. 15 two-dimensional images of the socket's interior are captured using a smartphone camera. A 3D model is generated using cloud-based software. Linear measurements were comparing between sockets and the related 3D models. 3D reconstruction accuracy averaged 2.6 ± 2.0 mm and 0.086 ± 0.078 L, which was less accurate than models obtained by high quality 3D scanners. However, this method would provide a viable 3D digital socket reproduction that is accessible and low-cost, after processing in prosthetic CAD software. Clinical relevance The described method provides a low-cost and accessible means to digitize a socket interior for use in prosthetic CAD/CAM systems, employing a smartphone camera and cloud-based photogrammetry software.

  5. Prosthetic bioabsorbable mesh for hiatal hernia repair during sleeve gastrectomy.

    Science.gov (United States)

    Clapp, Benjamin

    2013-01-01

    Laparoscopic sleeve gastrectomy has become a valuable primary bariatric operation. It has an acceptable complication profile and amount of weight loss. However, one of the most distressing complications to the patient is reflux postoperatively. There is thought to be a relationship between a hiatal hernia and postoperative reflux. There is disagreement on how to address a hiatal hernia intraoperatively, and the use of mesh is controversial. Our objectives were to examine the use of a prosthetic bioabsorbable mesh for repair of a large hiatal hernia during a sleeve gastrectomy and to examine the incidence of reflux and mesh-related complications in the near term. This is a case series of patients with hiatal hernia undergoing a primary sleeve gastrectomy. None of the patients had a previous hiatal hernia repair. Three patients with large hiatal hernias diagnosed preoperatively or intraoperatively were included. The hiatus of the diaphragm was repaired with a posterior crural closure, and a piece of prosthetic bioabsorbable mesh was placed posteriorly to reinforce the repair. There were 3 patients. The mean follow-up period was 12 months. There were no mesh-related complications. One of the patients needed to resume proton pump inhibitors to control reflux. The use of a prosthetic bioabsorbable mesh to repair a hiatal hernia simultaneously with a sleeve gastrectomy is safe. There were no mesh-related complications at 1 year.

  6. Orientation and mobility assessment in retinal prosthetic clinical trials.

    Science.gov (United States)

    Geruschat, Duane R; Bittner, Ava K; Dagnelie, Gislin

    2012-09-01

    The purpose of this study was to develop an orientation and mobility (O&M) assessment protocol to implement in subjects who have been implanted with an artificial silicon retina (ASR), and to use this experience to propose a research agenda for O&M with prosthetic vision. A controlled and naturalistic assessment was developed that included walking a prescribed obstacle course and travel to and from a hospital cafeteria. Subjects were tested before and 3 and 6 months after being implanted with the ASR. Outcome measures were walking speed and number of contacts with obstacles. The experiences from this study led to a proposed research agenda in O&M. Eight subjects with retinitis pigmentosa participated in this study. The vision status of the subjects ranged from mobility after implantation. Three subjects self-reported enhancements of travel after implantation, but this enhancement was not observed. This study demonstrates that mobility might not be improved with prosthetic vision. The proposed research agenda emphasizes the importance of developing individualized assessments, identifying specific items of orientation rather than mobility for measuring the effect of prosthetic vision, and to develop and evaluate instructional programs that may be needed to obtain the full benefit of the technology.

  7. Learning prosthetic vision: a virtual-reality study.

    Science.gov (United States)

    Chen, Spencer C; Hallum, Luke E; Lovell, Nigel H; Suaning, Gregg J

    2005-09-01

    Acceptance of prosthetic vision will be heavily dependent on the ability of recipients to form useful information from such vision. Training strategies to accelerate learning and maximize visual comprehension would need to be designed in the light of the factors affecting human learning under prosthetic vision. Some of these potential factors were examined in a visual acuity study using the Landolt C optotype under virtual-reality simulation of prosthetic vision. Fifteen normally sighted subjects were tested for 10-20 sessions. Potential learning factors were tested at p Learning was most evident across-sessions, though 17% of sessions did express significant within-session trends. Learning was highly concentrated toward a critical range of optotype sizes, and subjects were less capable in identifying the closed optotype (a Landolt C with no gap, forming a closed annulus). Training for implant recipients should target these critical sizes and the closed optotype to extend the limit of visual comprehension. Although there was no evidence that image processing affected overall learning, subjects showed varying personal preferences.

  8. Iodine-125 orbital brachytherapy with a prosthetic implant in situ

    Energy Technology Data Exchange (ETDEWEB)

    Stannard, Clare [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Radiation Oncology; Maree, Gert; Munro, Roger [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Medical Physics; Lecuona, Karin [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Ophthalmology; Sauerwein, Wolfgang [Universitaetsklinikum Essen (Germany). Strahlenklinik, NCTeam

    2011-05-15

    Purpose: Brachytherapy is one method of irradiating the orbit after enucleation of an eye with a malignant tumor that has a potential to recur. It consists of 6 trains of I-125 seeds placed around the periphery of the orbit, a shorter central train, and a metal disc, loaded with seeds, placed beneath the eyelids. The presence of a prosthetic orbital implant requires omission of the central train and adjustment of the activity of the seeds in the anterior orbit around the prosthesis. Patients and Methods: This is a retrospective review of the technical modifications and outcome of 12 patients treated in this manner: 6 with retinoblastoma, 5 with malignant melanoma, and 1 with an intraocular rhabdomyosarcoma. The median dose was 35.5 Gy in 73 hours for retinoblastoma and 56 Gy in 141 hours for malignant melanoma. Patients with retinoblastoma and rhabdomyosarcoma also received chemotherapy. Results: The tubes can be placed satisfactorily around the prosthesis. The increased activity in the anterior half of the tubes produced comparable dose distributions. There have been no orbital recurrences, no extrusion of the prosthesis, and cosmesis is good. Conclusion: Insertion of a prosthetic implant at the time of enucleation greatly enhances the subsequent cosmetic appearance. This should be encouraged unless there is frank tumor in the orbit. Orbital brachytherapy without the central train continues to give excellent local control. The short treatment time and good cosmesis are added advantages. The patient is spared the expense and inconvenience of removing and replacing the prosthetic implant. (orig.)

  9. Prosthetic Leg Control in the Nullspace of Human Interaction.

    Science.gov (United States)

    Gregg, Robert D; Martin, Anne E

    2016-07-01

    Recent work has extended the control method of virtual constraints, originally developed for autonomous walking robots, to powered prosthetic legs for lower-limb amputees. Virtual constraints define desired joint patterns as functions of a mechanical phasing variable, which are typically enforced by torque control laws that linearize the output dynamics associated with the virtual constraints. However, the output dynamics of a powered prosthetic leg generally depend on the human interaction forces, which must be measured and canceled by the feedback linearizing control law. This feedback requires expensive multi-axis load cells, and actively canceling the interaction forces may minimize the human's influence over the prosthesis. To address these limitations, this paper proposes a method for projecting virtual constraints into the nullspace of the human interaction terms in the output dynamics. The projected virtual constraints naturally render the output dynamics invariant with respect to the human interaction forces, which instead enter into the internal dynamics of the partially linearized prosthetic system. This method is illustrated with simulations of a transfemoral amputee model walking with a powered knee-ankle prosthesis that is controlled via virtual constraints with and without the proposed projection.

  10. A cross-validation of the provisional diagnostic instrument (PDI-4

    Directory of Open Access Journals (Sweden)

    Faries Douglas E

    2012-10-01

    Full Text Available Abstract Background The Provisional Diagnostic Instrument (PDI-4 is a brief, adult self-report instrument for 4 common psychiatric diagnoses in primary care patients: major depressive episode (MDE, generalized anxiety disorder (GAD, attention deficit hyperactivity disorder (ADHD, and bipolar I disorder based on past or present mania. Our objective was to assess validity of the PDI-4 in a population independent of the study population originally used to develop the scale. Methods An online version of the 17-item PDI-4 was administered to 1,047 adults in the US; respondents also completed the PHQ-9, HADS-A, CAARS-S, and MDQ within the online survey. Respondents self-reported diagnosis by a healthcare professional with the terms depression (n=221, anxiety (n=218, attention deficit disorder (n=206, bipolar or manic depressive disorder (n=195, or none of these (n=207. Statistical analyses examined convergent and discriminant validity, and operating characteristics of the PDI-4 relative to the individual, validated, self-rated scales PHQ-9, HADS-A, CAARS-S, and MDQ, for each PDI-4 diagnosis. Results Convergent validity of the PDI-4 was supported by strong correlations with the corresponding individual scales (range of 0.63 [PDI-4 and MDQ] to 0.87 [PDI-4 and PHQ-9]. Operating characteristics of the PDI-4 were similar to results in the previous site-based study. The scale exhibited moderate sensitivities (0.52 [mania] to 0.70 [ADHD] and strong specificities (0.86 [mania] to 0.92 [GAD] using the individual scales as the gold standards. ANOVAs demonstrated that PDI-4 discriminated between subsets of patients defined by pre-specified severity level cutoff scores of the individual scales. However, overlapping symptoms and co-morbidities made differentiation between mental diagnoses much weaker than differentiation from the control group with none of the diagnoses. Conclusions The PDI-4 appears to be a suitable, brief, self-rated tool for provisional

  11. Physiologically-based pharmacokinetic model for Fentanyl in support of the development of Provisional Advisory Levels

    Energy Technology Data Exchange (ETDEWEB)

    Shankaran, Harish, E-mail: harish.shankaran@pnnl.gov [Computational Biology and Bioinformatics Group, Pacific Northwest National Laboratory, Richland, WA 99352 (United States); Adeshina, Femi [National Homeland Security Research Center, United States Environmental Protection Agency, Washington, DC 20460 (United States); Teeguarden, Justin G. [Systems Toxicology Group, Pacific Northwest National Laboratory, Richland, WA 99352 (United States)

    2013-12-15

    Provisional Advisory Levels (PALs) are tiered exposure limits for toxic chemicals in air and drinking water that are developed to assist in emergency responses. Physiologically-based pharmacokinetic (PBPK) modeling can support this process by enabling extrapolations across doses, and exposure routes, thereby addressing gaps in the available toxicity data. Here, we describe the development of a PBPK model for Fentanyl – a synthetic opioid used clinically for pain management – to support the establishment of PALs. Starting from an existing model for intravenous Fentanyl, we first optimized distribution and clearance parameters using several additional IV datasets. We then calibrated the model using pharmacokinetic data for various formulations, and determined the absorbed fraction, F, and time taken for the absorbed amount to reach 90% of its final value, t90. For aerosolized pulmonary Fentanyl, F = 1 and t90 < 1 min indicating complete and rapid absorption. The F value ranged from 0.35 to 0.74 for oral and various transmucosal routes. Oral Fentanyl was absorbed the slowest (t90 ∼ 300 min); the absorption of intranasal Fentanyl was relatively rapid (t90 ∼ 20–40 min); and the various oral transmucosal routes had intermediate absorption rates (t90 ∼ 160–300 min). Based on these results, for inhalation exposures, we assumed that all of the Fentanyl inhaled from the air during each breath directly, and instantaneously enters the arterial circulation. We present model predictions of Fentanyl blood concentrations in oral and inhalation scenarios relevant for PAL development, and provide an analytical expression that can be used to extrapolate between oral and inhalation routes for the derivation of PALs. - Highlights: • We develop a Fentanyl PBPK model for relating external dose to internal levels. • We calibrate the model to oral and inhalation exposures using > 50 human datasets. • Model predictions are in good agreement with the available

  12. Examining the provisional guidelines for weight gain in twin pregnancies: a retrospective cohort study.

    Science.gov (United States)

    Lutsiv, Olha; Hulman, Adam; Woolcott, Christy; Beyene, Joseph; Giglia, Lucy; Armson, B Anthony; Dodds, Linda; Neupane, Binod; McDonald, Sarah D

    2017-09-29

    Weight gain during pregnancy has an important impact on maternal and neonatal health. Unlike the Institute of Medicine (IOM) recommendations for weight gain in singleton pregnancies, those for twin gestations are termed "provisional", as they are based on limited data. The objectives of this study were to determine the neonatal and maternal outcomes associated with gaining weight below, within and above the IOM provisional guidelines on gestational weight gain in twin pregnancies, and additionally, to explore ranges of gestational weight gain among women who delivered twins at the recommended gestational age and birth weight, and those who did not. A retrospective cohort study of women who gave birth to twins at ≥20 weeks gestation, with a birth weight ≥ 500 g was conducted in Nova Scotia, Canada (2003-2014). Our primary outcome of interest was small for gestational age (<10th percentile). In order to account for gestational age at delivery, weekly rates of 2nd and 3rd trimester weight gain were used to categorize women as gaining below, within, or above guidelines. We performed traditional regression analyses for maternal outcomes, and to account for the correlated nature of the neonatal outcomes in twins, we used generalized estimating equations (GEE). A total of 1482 twins and 741 mothers were included, of whom 27%, 43%, and 30% gained below, within, and above guidelines, respectively. The incidence of small for gestational age in these three groups was 30%, 21%, and 20%, respectively, and relative to gaining within guidelines, the adjusted odds ratios were 1.44 (95% CI 1.01-2.06) for gaining below and 0.92 (95% CI 0.62-1.36) for gaining above. The gestational weight gain in women who delivered twins at 37-42 weeks with average birth weight ≥ 2500 g and those who delivered twins outside of the recommend ranges were comparable to each other and the IOM recommendations. While gestational weight gain below guidelines for twins was associated with some

  13. A comparison of the traditional casting method and the galvanoforming technique in gold alloy prosthetic restorations

    Directory of Open Access Journals (Sweden)

    Sarna-Boś Katarzyna

    2015-09-01

    Full Text Available Gold is a dental material with very good mechanical properties. It is also aesthetic and biocompatible with the tissues of the oral cavity even at 100% purity. Prosthetic restorations made of pure gold or its alloys can be practiced either through a normal casting, as well as through using the galvanoforming technique. The electrolytic method was first introduced into dentistry about 20 years ago and it allows for producing “pure” gold (which means 99.99% Au. The lack of additions of other metals improves the properties of dental prostheses, such as marginal tightness, esthetics, biocompatibility, and it helps in eliminating any allergic reactions. The literature review presented in this paper is a comparison of the traditional casting method with the newer galvanoforming technique.

  14. One-year incidence of prosthetic joint infection in total hip arthroplasty

    DEFF Research Database (Denmark)

    Gundtoft, P H; Pedersen, A B; Schønheyder, Henrik C.

    2017-01-01

    . The most common micro-organisms identified in the 271 PJI were Staphylococcus aureus (36%) and coagulase-negative staphylococci (CoNS) (33%); others commonly identified included Enterobacteriaceae, enterococci, and streptococci. Antimicrobial resistance to beta-lactams and gentamicin did not change during......OBJECTIVE: To examine the trend of Prosthetic Joint Infections (PJI) following primary total hip arthroplasty (THA) and the antimicrobial resistance of the bacteria causing these infections. MATERIALS AND METHODS: We identified a population-based cohort of patients in the Danish Hip Arthroplasty...... the study period. CONCLUSION: The risk of PJI within 1-year after primary THA and the antimicrobial resistance of the most prevalent bacteria remained unchanged during the 2005-2014 study period....

  15. Mycobacterium avium intracellulare complex causing olecranon bursitis and prosthetic joint infection in an immunocompromised host

    Directory of Open Access Journals (Sweden)

    Eugene M. Tan

    2016-01-01

    Full Text Available Case: A 73-year-old immunocompromised male presented with recurrent left elbow swelling due to Mycobacterium avium intracellulare complex (MAC olecranon bursitis. 3 years after completing MAC treatment, he underwent right total knee arthroplasty (TKA. 1 year later, he developed TKA pain and swelling and was diagnosed with MAC prosthetic joint infection (PJI. He underwent TKA resection, reimplantation, and 12 months of anti-MAC therapy. This patient is the seventh case report of MAC olecranon bursitis and the third case report of MAC PJI. He is the only report of both MAC olecranon bursitis and PJI occurring in the same patient. Informed consent: This patient was informed and agreed to the publication of this material.

  16. Single- and dual-energy quantitative CT adjacent to acetabular prosthetic components

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder; Andersen, Poul Erik; Torfing, Trine

    2017-01-01

    and to compare BMD measurements in single and dual energy CT (SECT and DECT). Methods and Materials: 10 male patients with uncemented hip prosthetics were scanned and rescanned using 120 kVp SECT and DECT with virtual monochromatic images reconstructed at 130 keV. Hemispherical ROIs were defined slice......-by-slice and bone mineral density was calculated using a calibration phantom. Median time between ROI drawings was 6 days. Results: The mean BMD for repeated SECT scans was 430 mg/ccm with a between scan difference of 18 mg/ccm, p=0.001. ICC was 0.98 (95%CI: 0.73 to 1). For DECT the mean BMD was 162 mg....../ccm with a difference of 11 mg/ccm, pSECT and -30 to 7 in DECT. Repeatability coefficients were 33 and 18 mg/ccm for SECT and DECT respectively. The difference was not statistically significant. Conclusion: The intraobserver...

  17. Brief report: biomarkers of aortic vascular prosthetic graft infection in a porcine model with Staphylococcus aureus

    DEFF Research Database (Denmark)

    Langerhuus, S. N.; Tønnesen, E. K.; Jensen, K. H.

    2010-01-01

    Aortic vascular prosthetic graft infection (AVPGI) with Staphylococcus aureus is a feared post-operative complication. This study was conducted to evaluate the clinical signs and potential biomarkers of infection in a porcine AVPGI model. The biomarkers evaluated were: C-reactive protein (CRP......), fibrinogen, white blood cells (WBC), major histocompatibility complex II (MHC II) density, lymphocyte CD4:CD8 ratio and tumour necrosis factor-alpha (TNF-α) in vitro responsiveness. Sixteen pigs were included in the study, and randomly assigned into four groups (n = 4): “SHAM” pigs had their infra-renal...... aorta exposed by laparotomy; “CLEAN” pigs had an aortic graft inserted; “LOW” and “HIGH” pigs had an aortic graft inserted and, subsequently, S. aureus were inoculated on the graft material (5 × 104 colony-forming units [CFU] and 1 × 106 CFU, respectively). Biomarkers were evaluated prior to surgery...

  18. CLINICAL EVALUATION OF CERAMIC PROSTHETIC RESTORATIONS ON A ZIRCONIUM STRUCTURE AFTER 4 YEARS

    Directory of Open Access Journals (Sweden)

    Delia Cristina Bahrim

    2011-09-01

    Full Text Available The mechanical properties of zirconium are optimum, comparatively with the other ceramic materials. Initial and fracture resistance, as well as its resistance to flexion, the white, opaque colour, permitting several shades, the special biological properties, largely recommend largescale utilization of zirconium in prosthetic restorations. Zirconium crowns and bridges were realized in 129 patients (81 women and 48 boys, with ages between 15 and 57 years, along 4 years. The working method applied in the laboratory made use of the CAD-CAM system, followed by scanning on a Dental Wings scanner and a CAM burring system from Wieland 917, 18. In a few cases, repeated evaluations demonstrated accidents and complications, such as skeletal fractures, ceramic chipping, decementation, etc.

  19. Polymeric trileaflet prosthetic heart valves: evolution and path to clinical reality

    Science.gov (United States)

    Claiborne, Thomas E; Slepian, Marvin J; Hossainy, Syed; Bluestein, Danny

    2013-01-01

    Present prosthetic heart valves, while hemodynamically effective, remain limited by progressive structural deterioration of tissue valves or the burden of chronic anticoagulation for mechanical valves. An idealized valve prosthesis would eliminate these limitations. Polymeric heart valves (PHVs), fabricated from advanced polymeric materials, offer the potential of durability and hemocompatibility. Unfortunately, the clinical realization of PHVs to date has been hampered by findings of in vivo calcification, degradation and thrombosis. Here, the authors review the evolution of PHVs, evaluate the state of the art of this technology and propose a pathway towards clinical reality. In particular, the authors discuss the development of a novel aortic PHV that may be deployed via transcatheter implantation, as well as its optimization via device thrombogenicity emulation. PMID:23249154

  20. 21 CFR 872.3690 - Tooth shade resin material.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tooth shade resin material. 872.3690 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3690 Tooth shade resin material. (a) Identification. Tooth shade resin material is a device composed of materials such as bisphenol-A glycidyl...

  1. Reinforcement of acrylic resins for provisional fixed restorations. Part III: effects of addition of titania and zirconia mixtures on some mechanical and physical properties.

    Science.gov (United States)

    Panyayong, W; Oshida, Y; Andres, C J; Barco, T M; Brown, D T; Hovijitra, S

    2002-01-01

    Acrylic resins have been used in many different applications in dentistry, especially in the fabrication of provisional fixed partial dentures. Ideally, a provisional crown and bridge material should be easy to handle and should protect teeth against physical, chemical, and thermal injuries. Some of the problems associated with this use are related to the material's poor mechanical properties. It has been demonstrated that acrylic resin can be strengthened through the addition of structural component of different size distributed in the acrylic matrix, thus forming a composite structure. The purpose of this study was to investigate the addition effects of mixtures of titania (titanium dioxide, TiO(2)) powder and zirconia (zirconium dioxide, ZrO(2)) powder being incorporated with pre-polymerized beads mixed in monomer liquid, on some mechanical and physical properties of PMMA resin. The pre-polymerized powder poly(methyl methacrylate) resin was admixed with titania and zirconia powder. A mixing ratio was controlled by volume % of 0, 1.0, 2.0, and 3.0 (samples with 0 v/o served as control groups). For using mixture of titania and zirconia, total amount of the mixture was controlled by volume % of 1.0, 2.0, and 3.0, in which titania and zirconia were mixed at the ratio 1 :1, 1 :2 and 2 :1. Prior to mechanical tests, all rectangular-shaped samples (25 mm x 2 mm x 5 mm) were stored in 37 degrees C distilled water for 7 days after polishing all six sides of samples. Samples were then subjected to the three-point bending flexion test to evaluate the bending strength as well as the modulus of elasticity. Weight gain and exothermic reaction survey were investigated as well. All data were collected and analyzed with one-way analysis of variance (ANOVA) and Sidak method (p=0.05). It was found that the addition of particles generally decreased the water absorbed by the composite system. Only 1 percent by volume concentration of 1 :1 ratio and 2 percent by volume concentration

  2. The response of the anophthalmic socket to prosthetic eye wear.

    Science.gov (United States)

    Pine, Keith Raymond; Sloan, Brian; Stewart, Joanna; Jacobs, Robert John

    2013-07-01

    The aim of this study was to investigate the inflammatory response of the anophthalmic socket to prosthetic eye wear. One hundred and two prosthetic eye wearers were recruited for this observational study. Photographic grading scales were used to measure the severity of conjunctival inflammation and the extent and intensity of stained deposits on the prosthetic eyes. Tear volume was measured with the phenol red thread test. For mucoid discharge, visual analogue scales were used to assess frequency of occurrence, colour, volume and viscosity. For the prostheses, assessments were made of weight, shape, wearing time and frequency of cleaning. Anophthalmic sockets had more severe conjunctival inflammation than their companion eyes (p = 0.0001). The difference in inflammation between the companion eye and the anophthalmic socket was associated with discharge volume (p = 0.01) and discharge viscosity (p = 0.007) with greater difference in inflammation being associated with higher levels of discharge volume and viscosity. A greater difference in inflammation was also associated with less surface deposition (p = 0.009). No evidence of associations was found between difference in conjunctival inflammation and the other variables. Recently developed grading scales for measuring inflammation in anophthalmic sockets and deposits on prosthetic eyes were used for the first time in this study. It is recommended that in clinical practice, inflammation grades for both socket and companion eye conjunctivae be compared, when determining if prosthesis-induced inflammation is present. The finding that more discharge was associated with more conjunctival inflammation is logical but the finding that less inflammation was associated with more deposits is counter-intuitive to those familiar with the contact lens literature. The apparently benign nature of at least some deposits on the prostheses raises questions about the maintenance of prosthetic eyes. We conclude that the simple presence

  3. A survey of prosthetic eye wearers to investigate mucoid discharge

    Directory of Open Access Journals (Sweden)

    Pine K

    2012-05-01

    Full Text Available Keith Pine1, Brian Sloan2, Joanna Stewart3, Robert J Jacobs11Department of Optometry and Vision Science, 2Department of Ophthalmology, New Zealand National Eye Centre, 3Section of Epidemiology and Biostatistics, School of Population Health, University of Auckland, Auckland, New ZealandBackground: This study aimed to better understand the causes and treatments of mucoid discharge associated with prosthetic eye wear by reviewing the literature and surveying anophthalmic patients.Methods: An anonymous questionnaire was completed by 429 prosthetic eye wearers who used visual analog scales to self-measure their discharge experience for four discharge characteristics: frequency, color, volume, and viscosity. These characteristics were analyzed with age, ethnicity, years wearing a prosthesis, eye loss cause, removal and cleaning regimes, hand-washing behavior, age of current prosthesis, and professional repolishing regimes as explanatory variables. Eighteen ocularists’ Web sites containing comments on the cause and treatment of discharge were surveyed.Results: Associations were found between discharge frequency and cleaning regimes with more frequent cleaning accompanying more frequent discharge. Color was associated with years of wearing and age, with more years of wearing and older people having less colored discharge. Volume was associated with cleaning regimes with more frequent cleaners having more volume. Viscosity was associated with cleaning regimes and years of wearing with more frequent cleaning and shorter wearing time accompanying more viscous discharge. No associations were found between discharge characteristics and ethnicity, eye loss cause, hand washing, age of current prosthesis, or repolishing regimes. Forty-seven percent of ocularists’ Web sites advised that discharge was caused by surface deposits on the prosthesis, 29% by excessive handling of the prosthesis, and 24% by other causes.Conclusions: A standardized treatment

  4. Developing prescribing guidelines for microprocessor-controlled prosthetic knees in the South East England.

    Science.gov (United States)

    Sedki, Imad; Fisher, Keren

    2015-06-01

    Microprocessor-controlled prosthetic knees have gained increasing popularity over the last decade. Research supports their provision to address specific problems or to achieve certain rehabilitation goals. However, there are yet no agreed protocols or prescribing criteria to assist clinicians in the identification and appropriate selection of suitable users. The aim is to reach professionals' agreement on specific prescribing guidelines for microprocessor-controlled prosthetic knees. The study involved multidisciplinary teams from the Inter Regional Prosthetic Audit Group, representing nine Prosthetic Rehabilitation Centres in the South East England region. We used the Delphi technique with a total of three rounds to reach professionals' agreement. The prescribing guidelines were agreed and will be reviewed and updated depending on new research evidence and technical advances. This project is highly useful for professionals in a clinic setting to aid in appropriate patient selection and to justify the cost of prescribing microprocessor-controlled prosthetic knees. © The International Society for Prosthetics and Orthotics 2014.

  5. Mechanical design and performance specifications of anthropomorphic prosthetic hands: A review

    OpenAIRE

    Joseph T. Belter, MS, BS; Segil, Jacob L.; Aaron M. Dollar, PhD, SM, BS; Richard F. Weir, PhD

    2013-01-01

    In this article, we set forth a detailed analysis of the mechanical characteristics of anthropomorphic prosthetic hands. We report on an empirical study concerning the performance of several commercially available myoelectric prosthetic hands, including the Vincent, iLimb, iLimb Pulse, Bebionic, Bebionic v2, and Michelangelo hands. We investigated the finger design and kinematics, mechanical joint coupling, and actuation methods of these commercial prosthetic hands. The empirical findings are...

  6. The Effect of Different Fiber Concentrations on the Surface Roughness of Provisional Crown and Fixed Partial Denture Resin

    OpenAIRE

    Zortuk, Mustafa; K?l?c, Kerem; Uzun, Gulay; Ozturk, Ahmet; Kesim, Bulent

    2008-01-01

    Objectives The aim of this study was to investigate surface roughness in provisional crown acrylics, after polishing, reinforced with different concentrations of glass fibers. Methods A total of 48 disk-shaped specimens were prepared using autopolymerizing acrylic resin. These specimens were divided into four groups according to the level of glass fiber added: Group A (no fiber), Group B (0.5%), Group C (1%) and Group D (2%). After polishing the specimens, an average surface roughness (Ra) va...

  7. Randomized comparison between provisional and routine kissing-balloon technique after main vessel crossover stenting for coronary bifurcation lesions.

    Science.gov (United States)

    Yamawaki, Masahiro; Fujita, Masaki; Sasaki, Shinya; Tsurugida, Masanori; Nanasato, Mamoru; Araki, Motoharu; Hirano, Keisuke; Ito, Yoshiaki; Tsukahara, Reiko; Muramatsu, Toshiya

    2017-04-11

    We compared the myocardial ischemic burden of provisional and routine final kissing-balloon inflation (FKI) with the 1-stent strategy using a second-generation drug-eluting stent for coronary bifurcation lesions (CBL). There are no established guidelines for side branch (SB) intervention after main vessel stenting. In total, 113 CBL patients were randomized to receive different SB intervention strategies: provisional-FKI group (n = 57; FKI only when SB flow was TIMI stress myocardial perfusion scintigraphy with (99m)Tc was performed after 8 months. The regional summed-difference score (r-SDS) was calculated according to the coronary territory. The primary endpoint included target vessel ischemia (TVI; r-SDS ≥ 2) at 8 months, whereas the clinical primary endpoint was major adverse cardiovascular events (MACE) at 3 years. The percent (%) myocardial ischemia (100 × SDS/68) was also calculated. At 8 months, TVI was identified in 11 and 4% in the provisional-FKI and routine-FKI groups, respectively (p = 0.226). SB-binary restenosis (48 vs. 4%, p 10% myocardial ischemia) was not observed in the target vessel in either group. Long-term cumulative MACE were similar between the groups (9 vs. 14%; p = 0.358). Provisional-FKI according to TIMI-SB flow grade led to similar and acceptable myocardial ischemia, in comparison with routine-FKI, which may contribute to the identical long-term follow-up.

  8. Provisional Tic Disorder: What to tell parents when their child first starts ticcing

    Science.gov (United States)

    Black, Kevin J; Black, Elizabeth Rose; Greene, Deanna J.; Schlaggar, Bradley L.

    2016-01-01

    The child with recent onset of tics is a common patient in a pediatrics or child neurology practice. If the child’s first tic was less than a year in the past, the diagnosis is usually Provisional Tic Disorder (PTD). Published reviews by experts reveal substantial consensus on prognosis in this situation: the tics will almost always disappear in a few months, having remained mild while they lasted. Surprisingly, however, the sparse existing data may not support these opinions. PTD may have just as much importance for science as for clinical care. It provides an opportunity to prospectively observe the spontaneous remission of tics. Such prospective studies may aid identification of genes or biomarkers specifically associated with remission rather than onset of tics. A better understanding of tic remission may also suggest novel treatment strategies for Tourette syndrome, or may lead to secondary prevention of tic disorders. This review summarizes the limited existing data on the epidemiology, phenomenology, and outcome of PTD, highlights areas in which prospective study is sorely needed, and proposes that tic disorders may completely remit much less often than is generally believed. PMID:27158458

  9. Soft Tissue Augmentation Techniques in Implants Placed and Provisionalized Immediately: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Rosa Rojo

    2016-01-01

    Full Text Available The aim of this study was to evaluate the effectiveness of techniques for soft tissue augmentation in the placement of immediate implants with and without provisionalization and to assess the quality of the reports in the literature. Randomized clinical trials, prospective clinical trials, and case series were included in this review. Clinical questions were formulated and organised according to the PICOS strategy. An electronic search was performed in PubMed, Cochrane Central Register of Controlled Trials, Scopus, and ISI Web up until June 2016. Interexaminer agreement on eligibility (k=0.842; p=0.103 and quality (k=0.933; p<0.001 was high. Methodological approaches were assessed using criteria based on design related forms designed by the Dutch Cochrane Collaboration. Finally, 14 papers were identified. In two studies, the implant survival was 90%; for the rest of the studies it was 100%. All studies reported favourable aesthetic, biological, and radiographic outcomes. Surgical and biomechanical complications of this technique were not relevant. This technique effectively compensates for the expected loss of volume of the oral soft tissues and maintains high success rates with good aesthetic results over time.

  10. Provisional Matrix Deposition in Hemostasis and Venous Insufficiency: Tissue Preconditioning for Nonhealing Venous Ulcers

    Science.gov (United States)

    Parker, Tony J.; Broadbent, James A.; McGovern, Jacqui A.; Broszczak, Daniel A.; Parker, Christina N.; Upton, Zee

    2015-01-01

    Significance: Chronic wounds represent a major burden on global healthcare systems and reduce the quality of life of those affected. Significant advances have been made in our understanding of the biochemistry of wound healing progression. However, knowledge regarding the specific molecular processes influencing chronic wound formation and persistence remains limited. Recent Advances: Generally, healing of acute wounds begins with hemostasis and the deposition of a plasma-derived provisional matrix into the wound. The deposition of plasma matrix proteins is known to occur around the microvasculature of the lower limb as a result of venous insufficiency. This appears to alter limb cutaneous tissue physiology and consequently drives the tissue into a ‘preconditioned’ state that negatively influences the response to wounding. Critical Issues: Processes, such as oxygen and nutrient suppression, edema, inflammatory cell trapping/extravasation, diffuse inflammation, and tissue necrosis are thought to contribute to the advent of a chronic wound. Healing of the wound then becomes difficult in the context of an internally injured limb. Thus, interventions and therapies for promoting healing of the limb is a growing area of interest. For venous ulcers, treatment using compression bandaging encourages venous return and improves healing processes within the limb, critically however, once treatment concludes ulcers often reoccur. Future Directions: Improved understanding of the composition and role of pericapillary matrix deposits in facilitating internal limb injury and subsequent development of chronic wounds will be critical for informing and enhancing current best practice therapies and preventative action in the wound care field. PMID:25785239

  11. Canadian Federalism in Design and Practice: The Mechanics of a Permanently Provisional Constitution

    Directory of Open Access Journals (Sweden)

    Gardner James A.

    2017-12-01

    Full Text Available This paper examines the interaction between constitutional design and practice through a case study of Canadian federalism. Focusing on the federal architecture of the Canadian Constitution, the paper examines how subnational units in Canada actually compete with the central government, emphasizing the concrete strategies and tactics they most commonly employ to get their way in confrontations with central authority. The evidence affirms that constitutional design and structure make an important difference in the tactics and tools available to subnational units in a federal system, but that design is not fully constraining: there is considerable evidence of extraconstitutional innovation and improvisation by governments. Furthermore, changes in practice initiated by Canadian subnational actors have produced changes in the allocation of national and subnational authority that are plausibly characterized as constitutional in magnitude. The paper concludes that the design of the Canadian federal system may inadvertently undermine its capacity to stabilize itself at any particular point of constitutional evolution, making it ‘permanently provisional.’

  12. Soft Tissue Augmentation Techniques in Implants Placed and Provisionalized Immediately: A Systematic Review.

    Science.gov (United States)

    Rojo, Rosa; Prados-Frutos, Juan Carlos; Manchón, Ángel; Rodríguez-Molinero, Jesús; Sammartino, Gilberto; Calvo Guirado, José Luis; Gómez-de Diego, Rafael

    2016-01-01

    The aim of this study was to evaluate the effectiveness of techniques for soft tissue augmentation in the placement of immediate implants with and without provisionalization and to assess the quality of the reports in the literature. Randomized clinical trials, prospective clinical trials, and case series were included in this review. Clinical questions were formulated and organised according to the PICOS strategy. An electronic search was performed in PubMed, Cochrane Central Register of Controlled Trials, Scopus, and ISI Web up until June 2016. Interexaminer agreement on eligibility (k = 0.842; p = 0.103) and quality (k = 0.933; p < 0.001) was high. Methodological approaches were assessed using criteria based on design related forms designed by the Dutch Cochrane Collaboration. Finally, 14 papers were identified. In two studies, the implant survival was 90%; for the rest of the studies it was 100%. All studies reported favourable aesthetic, biological, and radiographic outcomes. Surgical and biomechanical complications of this technique were not relevant. This technique effectively compensates for the expected loss of volume of the oral soft tissues and maintains high success rates with good aesthetic results over time.

  13. ¿Cuánto cuesta el rescate bancario?: una estimación provisional

    Directory of Open Access Journals (Sweden)

    José Francisco Bellod Redondo

    2013-01-01

    Full Text Available en este trabajo presentamos una estimación provisional del importe de los recursos movilizados por las Administraciones Públicas en favor de los bancos españoles. Como el proceso de rescate bancario aún no ha finalizado y, como ciertos costes han de tener lugar en el futuro, la cuantificación es necesariamente incompleta. Según nuestras estimaciones los recursos inyectados ascienden a día de hoy a más de 126.000 millones de euros (11´9% del PIB, de los cuales más de 41.000 millones son irrecuperables. La venta de bancos a precios simbólicos ha sido una operación muy gravosa por la cual se han perdido 13.548 millones de euros. Aparte habría que computar los recursos procedentes del Banco Central Europeo (BCE, más de 340.000 millones de euros.

  14. Work and organisation in wood fuel systems. Provisional results from a pilot project

    Energy Technology Data Exchange (ETDEWEB)

    Ager, B. [Swedish Univ. of Agricultural Sciences, Dept. of Operational Efficiency, Garpenberg (Sweden); Soederqvist, A. [WE-Consulting AB, Tyresoe (Sweden)

    1996-12-31

    The use of wood fuels in Sweden has increased dramatically over the last few years. So far wood chips from tops and limbs and waste from the lumber/wood working industry have been the primary fuel sources. However, upgraded wood fuels, mainly in the shape of pellets, are rapidly gaining ground and used wood and short rotation forests are other sources under expansion. In the modern wood fuel sector new technology and production systems are being tested and introduced and new organisational structures and enterprises are developing. But rather few studies have been carried out concerning the conditions for the workers engaged in the production systems. An area which has attracted several studies is health hazards caused by various kinds of air pollutants, such as dust and moulds, but in most other areas knowledge is rather scarce. After a minor introductory study a comprehensive pilot project was formulated. The project is titled `Work and organisation in wood fuel systems` and will run from July 1996 to March 1998. The main objective of this project is to investigate working environment and work organisation in wood fuel systems in order to identify problems and ways of achieving improvement and development. This paper will discuss provisional results from studies of three selected production systems, which are especially common or expanding - harvest and transport of logging residues, production of wood pellets, and heating plants. (au)

  15. Ceramics in Restorative and Prosthetic DENTISTRY1

    Science.gov (United States)

    Kelly, J. Robert

    1997-08-01

    This review is intended to provide the ceramic engineer with information about the history and current use of ceramics in dentistry, contemporary research topics, and potential research agenda. Background material includes intra-oral design considerations, descriptions of ceramic dental components, and the origin, composition, and microstructure of current dental ceramics. Attention is paid to efforts involving net-shape processing, machining as a forming method, and the analysis of clinical failure. A rationale is presented for the further development of all-ceramic restorative systems. Current research topics receiving attention include microstructure/processing/property relationships, clinical failure mechanisms and in vitro testing, wear damage and wear testing, surface treatments, and microstructural modifications. The status of the field is critically reviewed with an eye toward future work. Significant improvements seem possible in the clinical use of ceramics based on engineering solutions derived from the study of clinically failed restorations, on the incorporation of higher levels of "biomimicry" in new systems, and on the synergistic developments in dental cements and adhesive dentin bonding.

  16. Effect of dentin adhesives used as sealers and provisional cementation on bond strength of a resin cement to dentin.

    Science.gov (United States)

    Chieffi, Nicoletta; Sadek, Fernanda; Monticelli, Francesca; Goracci, Cecilia; Grandini, Simone; Davidson, Carel; Tay, Franklin R; Ferrari, Marco

    2006-04-01

    To evaluate the effects of dentin adhesives employed as resin sealers and provisional cementation on the bond strengths of a resin cement to dentin. A two-step etch-and-rinse adhesive (Excite DSC--Group 1) and two-step self-etch adhesive (AdheSE--Group 2) were applied to exposed dentin surfaces prepared from human molars (N=4). Water was used instead of a resin sealer in control Groups 3 and 4. A eugenol-free provisional cement (except for Group 4) was applied to the treated surfaces. After storing in distilled water for 1 week, the provisional cement was removed and cylindrical composite blocks were luted with a resin cement (Variolink II). 0.9 x 0.9 mm sticks were produced from these luted specimens for microtensile bond testing and SEM examination. One-way ANOVA revealed that neither the resin sealer nor the temporary eugenol-free cement had a negative effect on the final bond strength (P> 0.05). Mixed failures were predominantly identified from SEM.

  17. Virtual Control of Prosthetic Hand Based on Grasping Patterns and Estimated Force from Semg

    OpenAIRE

    Zhu Gao-Ke; Xu Li-Sha; Zhang Yi; Deng Hua

    2016-01-01

    Myoelectric prosthetic hands aim to serve upper limb amputees. The myoelectric control of the hand grasp action is a kind of real-time or online method. Thus it is of great necessity to carry on a study of online prosthetic hand electrical control. In this paper, the strategy of simultaneous EMG decoding of grasping patterns and grasping force was realized by controlling a virtual multi-degree-freedom prosthetic hand and a real one-degree-freedom prosthetic hand simultaneously. The former rea...

  18. Prosthetic management 56 years after rotationplasty due to proximal femoral focal deficiency (PFFD).

    Science.gov (United States)

    Roux, N; Pieters, S

    2007-09-01

    Proximal femoral focal deficiency (PFFD) is a rare congenital anomaly of the femur. Rotationplasty has been described as a reconstructive procedure in the management of PFFD. A 68-year-old woman with PFFD of the right leg and rotationplasty at the age of 12 years had prosthetic fitting problems after a fall. The authors describe the analysis of the prosthetic fitting problems and the considerations made in prosthetic management. Following a fall, 56 years after rotationplasty, this woman has a good prosthetic fitting and a satisfying level of functioning.

  19. Characterizing mobility from the prosthetic limb user's perspective: Use of focus groups to guide development of the Prosthetic Limb Users Survey of Mobility.

    Science.gov (United States)

    Hafner, Brian J; Morgan, Sara J; Abrahamson, Daniel C; Amtmann, Dagmar

    2016-10-01

    Input from target respondents in the development of patient-reported outcome measures is necessary to ensure that the instrument is meaningful. To solicit perspectives of prosthetic limb users about their mobility experiences and to inform development of the Prosthetic Limb Users Survey of Mobility. Qualitative study. Four focus groups of lower limb prosthesis users were held in different regions of the United States. Focus group transcripts were coded, and themes were identified. Feedback from participants was used to develop a framework for measuring mobility with a lower limb prosthesis. Focus group participants (N = 37) described mobility as a confluence of factors that included characteristics of the individual, activity, and environment. Identified themes were defined as individual characteristics, forms of movement, and environmental situations. Prosthetic mobility was conceptualized as movement activities performed in an environmental or situational context. Respondent feedback used to guide development of Prosthetic Limb Users Survey of Mobility established a foundation for a new person-centered measure of mobility with a prosthetic limb. Perspectives of target respondents are needed to guide development of instruments intended to measure health outcomes. Focus groups of prosthetic limb users were conducted to solicit experiences related to mobility with a lower limb prosthesis. Results were used to inform development of a clinically meaningful, person-centered instrument. © The International Society for Prosthetics and Orthotics 2015.

  20. Methodology for designing and manufacturing complex biologically inspired soft robotic fluidic actuators: prosthetic hand case study.

    Science.gov (United States)

    Thompson-Bean, E; Das, R; McDaid, A

    2016-10-31

    We present a novel methodology for the design and manufacture of complex biologically inspired soft robotic fluidic actuators. The methodology is applied to the design and manufacture of a prosthetic for the hand. Real human hands are scanned to produce a 3D model of a finger, and pneumatic networks are implemented within it to produce a biomimetic bending motion. The finger is then partitioned into material sections, and a genetic algorithm based optimization, using finite element analysis, is employed to discover the optimal material for each section. This is based on two biomimetic performance criteria. Two sets of optimizations using two material sets are performed. Promising optimized material arrangements are fabricated using two techniques to validate the optimization routine, and the fabricated and simulated results are compared. We find that the optimization is successful in producing biomimetic soft robotic fingers and that fabrication of the fingers is possible. Limitations and paths for development are discussed. This methodology can be applied for other fluidic soft robotic devices.

  1. In vitro testing of gentamicin-vancomycin loaded bone cement to prevent prosthetic joint infection.

    Science.gov (United States)

    Gallo, Jirí; Kolár, Milan; Florschütz, Anthony V; Novotný, Radek; Pantůcek, Roman; Kesselová, Michaela

    2005-06-01

    Sepsis is a greatly feared complication of total joint arthroplasty. One key question is how to prevent perioperative bacterial adherence, and therefore the potential for infectious complications. The objective of our study was to appraise the emerging capacity of staphylococcal survival on prosthetic materials and to analyze the in vitro effects of gentamicin and vancomycin loaded polymethylmethacrylate (PMMA) cement on bacterial adherence and growth. Hospital acquired staphylococcal strains were systematically inoculated on four orthopedic materials (ultrahigh molecular weight polyethylene, PMMA without antibiotic, commercially produced PMMA loaded with gentamicin, and manually mixed PMMA loaded with gentamicin and vancomycin). Staphylococci were identified using culture and biochemical tests. The inoculated material was allowed to incubate in a liquid broth growth media and subsequently prepared for scanning electron microscopy and bacterial growth quantification. Materials without antibiotics showed evidence of staphylococcal growth. PMMA loaded with only gentamicin grew methicillin-resistant Staphylococcus aureus. Gentamicin-vancomycin loaded PMMA completely inhibited any bacterial growth. Low-dose gentamicin-vancomycin loaded PMMA prevents staphylococcal colonization better than commercially manufactured PMMA loaded with gentamicin. We recommend this combination in high-risk procedures and revision surgeries requiring bone cement.

  2. Fiber-array based optogenetic prosthetic system for stimulation therapy

    Science.gov (United States)

    Gu, Ling; Cote, Chris; Tejeda, Hector; Mohanty, Samarendra

    2012-02-01

    Recent advent of optogenetics has enabled activation of genetically-targeted neuronal cells using low intensity blue light with high temporal precision. Since blue light is attenuated rapidly due to scattering and absorption in neural tissue, optogenetic treatment of neurological disorders may require stimulation of specific cell types in multiple regions of the brain. Further, restoration of certain neural functions (vision, and auditory etc) requires accurate spatio-temporal stimulation patterns rather than just precise temporal stimulation. In order to activate multiple regions of the central nervous system in 3D, here, we report development of an optogenetic prosthetic comprising of array of fibers coupled to independently-controllable LEDs. This design avoids direct contact of LEDs with the brain tissue and thus does not require electrical and heat isolation, which can non-specifically stimulate and damage the local brain regions. The intensity, frequency, and duty cycle of light pulses from each fiber in the array was controlled independently using an inhouse developed LabView based program interfaced with a microcontroller driving the individual LEDs. While the temporal profile of the light pulses was controlled by varying the current driving the LED, the beam profile emanating from each fiber tip could be sculpted by microfabrication of the fiber tip. The fiber array was used to stimulate neurons, expressing channelrhodopsin-2, in different locations within the brain or retina. Control of neural activity in the mice cortex, using the fiber-array based prosthetic, is evaluated from recordings made with multi-electrode array (MEA). We also report construction of a μLED array based prosthetic for spatio-temporal stimulation of cortex.

  3. Transparent biocompatible sensor patches for touch sensitive prosthetic limbs

    KAUST Repository

    Nag, Anindya

    2016-12-26

    The paper presents the fabrication of transparent, flexible sensor patches developed using a casting technique with polydimethylsiloxane (PDMS) as substrate and a nanocomposite of carbon nanotubes (CNTs) and PDMS as interdigital electrodes. The electrodes act as strain sensitive capacitor. The prototypes were used as touch sensitive sensors attached to the limbs. Experiments results show the sensitivity of the patches towards tactile sensing. The results are very promising and can play a key role in the development of a cost efficient sensing system attached to prosthetic limbs.

  4. New optimum humanoid hand design for prosthetic applications.

    Science.gov (United States)

    El-Sheikh, Mogeeb A; Taher, Mona F; Metwalli, Sayed M

    2012-04-30

    To address the need for a commercially feasible prosthetic hand, the current work presents the design of a new humanoid hand actuated using shape memory alloy (SMA) artificial muscle wires. The hand has 3 compliant fingers and a thumb attached to the palm. The palm structure is a novel design, which is based on the natural arches of the human hand to provide better grasping capabilities. A compact actuator module is proposed to house and cool the SMA wires. Design parameters of the hand were selected to maximize the work density. The hand is lightweight, low cost, and operates silently. It has functional opening and closing speeds and fingertip force.

  5. Wrist-arthrography for the determination of the prosthetic bed

    Energy Technology Data Exchange (ETDEWEB)

    Wuttge, R.; Kueffer, G.; Hahn, D.; Bauer, J.; Wilhelm, K.

    1988-03-01

    Arthrography was performed during the last 12 months in 14 patients who had 2 months to 10 years after implantation of a silicone-elastomere- or fascia-lata-prosthesis recurrent complaints in their operated wrists. Following an extensive radiological native examination either midcarpal or radiocarpal arthrography was performed in dependence of the site of carpal-bone-substitute. Inflammatory changes of the prosthetic bed, missing penetration of contrast medium into the periprosthetic space and other less common additional findings showed the advantages of the relatively handsome procedure.

  6. Cinema and Prosthetic Memory: The Case of the Korean War

    Directory of Open Access Journals (Sweden)

    Judith Keene

    2010-05-01

    Full Text Available This paper assesses the explanatory possibilities of the concept of prosthetic memory, with cinema as the enabler of popular understanding, when applied to the Korean War. The essay examines why it was that the conflict in Korea for many decades occupied a memory void and whether the explanations that have been offered for other similar “forgotten “wars are useful in relation to Korea. The analysis sugggests that cinema may be important in the formation of popular understanding but that there are serious analytical drawbacks in assuming that cinema can provide a window into popular mentalities.

  7. Laser Science and its Applications in Prosthetic Rehabilitation

    Science.gov (United States)

    Gounder, Revathy; Gounder, Srinivasan

    2016-01-01

    The minimal invasive nature of lasers, with quick tissue response and healing has made them a very attractive technology in various fields of dentistry which serves as a tool to create a better result than ever before. The rapid development of lasers and their wavelengths with variety of applications on soft and hard tissues may continue to have major impact on the scope and practice in prosthetic dentistry. The purpose of this article is to make every clinician familiar with the fundamentals of lasers and different laser systems to incorporate into their clinical practices. PMID:28491254

  8. The Role of Virtual Articulator in Prosthetic and Restorative Dentistry

    Science.gov (United States)

    Aljanakh, Mohammad

    2014-01-01

    Virtual reality is a computer based technology linked with the future of dentistry and dental practice. The virtual articulator is one such application in prosthetic and restorative dentistry based on virtual reality that will significantly reduce the limitations of the mechanical articulator, and by simulation of real patient data, allow analyses with regard to static and dynamic occlusion as well as to jaw relation. It is the purpose of this article to present the concepts and strategies for a future replacement of the mechanical articulator by a virtual one. Also, a brief note on virtual reality haptic system has been highlighted along with newly developed touch enabled virtual articulator. PMID:25177664

  9. Prosthetic rehabilitation of an orbital defect for a patient with hemifacial atrophy

    Directory of Open Access Journals (Sweden)

    Sanath Shetty

    2016-01-01

    Full Text Available Removal of an eye may be indicated in cases of congenital abnormality, severe trauma, or disease such as an infection, tumor, or malignancy. The disfigurement associated with a loss of an eye is often accompanied with physical problems, psychological trauma, and a poor quality of life. A prosthetic replacement is the treatment of choice to return the individual to his normal vocation by producing an acceptable and life-like appearance. This article describes prosthetic rehabilitation of a 19-year-old male suffering from facial hemiatrophy with the loss of his left eye due to retinoblastoma when he was 2-year-old using medically graded silicone material. The technique used is simple, cost effective, and easy way for fabrication and rehabilitation of an orbital defect using silicone prosthesis where retention is achieved by a combination of silicone adhesives and tapes, and to a very small extent by bony and soft tissue undercut, hence providing better esthetic and psychological outcome. The acrylic part of the prosthesis was adhered to the socket with the help of a two-way silicon adhesive tape. Since the patient had lost his eye when he was 2-year-old, the development of eye and periorbital tissue on the defect side lead to hemiatrophy; in our approach, we have attempted to build the prosthesis in par with the normal side so that the fullness on the defect side was restored to that of the contralateral side. The fabricated facial prosthesis was durable, esthetic, and had good retention.

  10. Deriving a provisional tolerable intake for intravenous exposure to silver nanoparticles released from medical devices.

    Science.gov (United States)

    Savery, Laura C; Viñas, René; Nagy, Amber M; Pradeep, Prachi; Merrill, Stephen J; Hood, Alan M; Malghan, Subhas G; Goering, Peter L; Brown, Ronald P

    2017-04-01

    Silver nanoparticles (AgNP) are incorporated into medical devices for their anti-microbial characteristics. The potential exposure and toxicity of AgNPs is unknown due to varying physicochemical particle properties and lack of toxicological data. The aim of this safety assessment is to derive a provisional tolerable intake (pTI) value for AgNPs released from blood-contacting medical devices. A literature review of in vivo studies investigating critical health effects induced from intravenous (i. v.) exposure to AgNPs was evaluated by the Annapolis Accords principles and Toxicological Data Reliability Assessment Tool (ToxRTool). The point of departure (POD) was based on an i. v. 28-day repeated AgNP (20 nm) dose toxicity study reporting an increase in relative spleen weight in rats with a 5% lower confidence bound of the benchmark dose (BMDL05) of 0.14 mg/kg bw/day. The POD was extrapolated to humans by a modifying factor of 1,000 to account for intraspecies variability, interspecies differences and lack of long-term toxicity data. The pTI for long-term i. v. exposure to 20 nm AgNPs released from blood-contacting medical devices was 0.14 μg/kg bw/day. This pTI may not be appropriate for nanoparticles of other physicochemical properties or routes of administration. The methodology is appropriate for deriving pTIs for nanoparticles in general. Published by Elsevier Inc.

  11. Provisional in-silico biopharmaceutics classification (BCS) to guide oral drug product development

    Science.gov (United States)

    Wolk, Omri; Agbaria, Riad; Dahan, Arik

    2014-01-01

    The main objective of this work was to investigate in-silico predictions of physicochemical properties, in order to guide oral drug development by provisional biopharmaceutics classification system (BCS). Four in-silico methods were used to estimate LogP: group contribution (CLogP) using two different software programs, atom contribution (ALogP), and element contribution (KLogP). The correlations (r2) of CLogP, ALogP and KLogP versus measured LogP data were 0.97, 0.82, and 0.71, respectively. The classification of drugs with reported intestinal permeability in humans was correct for 64.3%–72.4% of the 29 drugs on the dataset, and for 81.82%–90.91% of the 22 drugs that are passively absorbed using the different in-silico algorithms. Similar permeability classification was obtained with the various in-silico methods. The in-silico calculations, along with experimental melting points, were then incorporated into a thermodynamic equation for solubility estimations that largely matched the reference solubility values. It was revealed that the effect of melting point on the solubility is minor compared to the partition coefficient, and an average melting point (162.7°C) could replace the experimental values, with similar results. The in-silico methods classified 20.76% (±3.07%) as Class 1, 41.51% (±3.32%) as Class 2, 30.49% (±4.47%) as Class 3, and 6.27% (±4.39%) as Class 4. In conclusion, in-silico methods can be used for BCS classification of drugs in early development, from merely their molecular formula and without foreknowledge of their chemical structure, which will allow for the improved selection, engineering, and developability of candidates. These in-silico methods could enhance success rates, reduce costs, and accelerate oral drug products development. PMID:25284986

  12. Learning effects of repetitive administration of the Southampton Hand Assessment Procedure in novice prosthetic users

    NARCIS (Netherlands)

    Golea-Vasluian, Ecaterina; Bongers, Raoul M; Reinders-Messelink, Heleen A; Burgerhof, Johannes G M; Dijkstra, Pieter U.; van der Sluis, Corry K

    Objective: The Southampton Hand Assessment Procedure (SHAP) evaluates the functionality of normal, injured or prosthetic hands. The aim was to evaluate the learning effects of SHAP tasks and the appropriateness of the time limits applied per task in novice prosthetic users. Methods: Right-handed

  13. Brain activation during manipulation of the myoelectric prosthetic hand: a functional magnetic resonance imaging study.

    Science.gov (United States)

    Maruishi, Masaharu; Tanaka, Yoshiyuki; Muranaka, Hiroyuki; Tsuji, Toshio; Ozawa, Yoshiaki; Imaizumi, Satoshi; Miyatani, Makoto; Kawahara, Junichiro

    2004-04-01

    Neuroimaging data, particularly functional magnetic resonance imaging (fMRI) findings, have not been reported in users of the myoelectric or electromyographic (EMG) prosthetic hand. We developed a virtual EMG prosthetic hand system to eliminate mutual signal noise interference between fMRI imaging and the EMG prosthesis. We used fMRI to localize activation in the human brain during manipulation of the virtual EMG prosthetic hand. Fourteen right-handed normal subjects were instructed to perform repetitive grasping with the right hand with eyes closed (CEG); repetitive grasping with the right hand with eyes open to obtain visual feedback of their own hand movement (OEG); and repetitive grasping with the virtual EMG prosthetic hand with the eyes open to obtain visual feedback of the prosthetic hand movement (VRG). The specific site activated during manipulation of the EMG prosthetic hand was the right ventral premotor cortex. Both paradigms with visual feedback also (OEG and VRG) demonstrated activation in the right posterior parietal cortex. The center of activation of the right posterior parietal cortex shifted laterally for visual feedback with the virtual EMG prosthetic hand compared to a subject's own hand. The results suggest that the EMG prosthetic hand might be recognized in the brain as a high-performance alternative to a real hand, being controlled through a "mirror system" in the brain.

  14. Improved grasp force sensitivity for prosthetic hands through force-derivative feedback.

    Science.gov (United States)

    Engeberg, Erik D; Meek, Sanford

    2008-02-01

    Sensitivity of applied grasp force is improved for a myoelectrically controlled prosthetic hand under force control through normal force-derivative feedback. Benchtop experiments and results from 12 human test subjects indicate that normal force-derivative feedback can be used in prosthetic hands to help prevent accidental damage to delicate objects.

  15. A mechanism to compensate undesired stiffness in joints of prosthetic hands

    NARCIS (Netherlands)

    Smit, G.; Plettenbrug, D.H.; Van der Helm, F.C.T.

    2014-01-01

    Background: Cosmetic gloves that cover a prosthetic hand have a parasitic positive stiffness that counteracts the flexion of a finger joint. Objectives: Reducing the required input torque to move a finger of a prosthetic hand by compensating the parasitic stiffness of the cosmetic glove. Study

  16. Pregnancy with prosthetic heart valves - 30 years' nationwide experience in Denmark

    DEFF Research Database (Denmark)

    Sillesen, Martin; Hjortdal, Vibeke; Vejlstrup, Niels

    2011-01-01

    Pregnancy in women with prosthetic heart valves remains a risk factor for both mother and fetus, but unselected and unbiased outcome and complication data remain scarce. We analyzed nationwide outcome data from 1977 to 2007 for all pregnancies in women with prosthetic valves....

  17. 75 FR 65060 - Advisory Committee on Prosthetics and Special-Disabilities Programs; Notice of Meeting

    Science.gov (United States)

    2010-10-21

    ... advise the Secretary of Veterans Affairs on VA's prosthetics programs designed to provide state-of-the..., blindness or visual impairments, loss of extremities or loss of function, deafness or hearing impairment... November 10, the Committee will be briefed by the Chief Consultant for Prosthetics and Sensory Aids Service...

  18. 78 FR 48941 - Advisory Committee on Prosthetics and Special-Disabilities Programs, Notice of Meeting

    Science.gov (United States)

    2013-08-12

    ... Veterans Affairs on VA's prosthetics programs designed to provide state-of-the- art prosthetics and the... administered by the Secretary to serve Veterans with spinal cord injuries, blindness or visual impairments... Sensory Aids Service. On August 14, the Committee will receive a briefing on Telemedicine. No time will be...

  19. 76 FR 64429 - Advisory Committee on Prosthetics and Special-Disabilities Programs; Notice of Meeting

    Science.gov (United States)

    2011-10-18

    ... advise the Secretary of Veterans Affairs on VA's prosthetics programs designed to provide state-of-the..., blindness or visual impairments, loss of extremities or loss of function, deafness or hearing impairment..., Amputation System of Care; and Deputy Chief Consultant, Prosthetics and Sensory Aids Service. On November 2...

  20. Replantation versus Prosthetic Fitting in Traumatic Arm Amputations: A Systematic Review

    OpenAIRE

    Otto, Iris A.; Kon, Moshe; Schuurman, Arnold H.; van Minnen, L. Paul

    2015-01-01

    Background: Traumatic arm amputations can be treated with replantation or surgical formalization of the stump with or without subsequent prosthetic fitting. In the literature, many authors suggest the superiority of replantation. This systematic review compared available literature to analyze whether replantation is functionally and psychologically more profitable than formalization and prosthetic fitting in patients with traumatic arm amputation. Methods: Functional outcome and satisfaction ...

  1. 77 FR 14989 - Medicare Program; Revisions to the Durable Medical Equipment, Prosthetics, Orthotics, and...

    Science.gov (United States)

    2012-03-14

    ... defined at 42 CFR 400.202 as a hospital, a critical access hospital (CAH), a skilled nursing facility (SNF... equipment include blood glucose monitors, hospital beds, oxygen tents, and wheelchairs. Prosthetic devices... Act, the term ``prosthetic devices'' does not include parenteral and enteral nutrition nutrients...

  2. 21 CFR 872.3930 - Bone grafting material.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3930 Bone grafting material. (a) Identification... “Class II Special Controls Guidance Document: Dental Bone Grafting Material Devices.” (See § 872.1(e) for... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bone grafting material. 872.3930 Section 872.3930...

  3. 21 CFR 872.3645 - Subperiosteal implant material.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Subperiosteal implant material. 872.3645 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3645 Subperiosteal implant material. (a) Identification. Subperiosteal implant material is a device composed of titanium or cobalt chrome molybdenum...

  4. 21 CFR 872.3310 - Coating material for resin fillings.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Coating material for resin fillings. 872.3310... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3310 Coating material for resin fillings. (a) Identification. A coating material for resin fillings is a device intended to be applied to the...

  5. The principles and in vivo performance of the Edinburgh pivoted aerofoil-disc prosthetic heart valve.

    Science.gov (United States)

    Macleod, N; Turina, M; Wade, J D; Wheatley, D J

    1977-01-01

    Prototypes of the Edinburgh prosthetic heart valve, known from previous experiments in vitro to promote exceptionally smooth and undisturbed forward flow, have been shown here in canine experiments to possess hemodynamic characteristics not inferior to those of the Bjork-Shiley valve (a present standard of excellence). In addition, we report a low incidence of valve thrombus deposition among calves in which this prototype valve, fabricated from the conventional materials, Delrin and stainless steel, has been implanted in the tricuspid site for up to 100 days without use of anticoagulants. This suggests that the design of the valve is such as to render it of low thrombogenicity. The new valve is designed for fabrication throughout in vitreous or pyro-coated carbon, materials of very high inherent athrombogenicity. It appears from the results discussed here that the developed form of the prosthesis, composed wholly of these athrombogenic materials, is likely to have both acceptable hemodynamic characteristics and an exceptionally low tendency to form thrombus. The introduction of such valves promises to be very advantageous and the results given here appear to warrant their development as the next stage of this program.

  6. The EBC TWO Study (European Bifurcation Coronary TWO): A Randomized Comparison of Provisional T-Stenting Versus a Systematic 2 Stent Culotte Strategy in Large Caliber True Bifurcations.

    Science.gov (United States)

    Hildick-Smith, David; Behan, Miles W; Lassen, Jens F; Chieffo, Alaide; Lefèvre, Thierry; Stankovic, Goran; Burzotta, Francesco; Pan, Manuel; Ferenc, Miroslaw; Bennett, Lorraine; Hovasse, Thomas; Spence, Mark J; Oldroyd, Keith; Brunel, Philippe; Carrie, Didier; Baumbach, Andreas; Maeng, Michael; Skipper, Nicola; Louvard, Yves

    2016-09-01

    For the treatment of coronary bifurcation lesions, a provisional strategy is superior to systematic 2-stent techniques for the most bifurcation lesions. However, complex anatomies with large side branches (SBs) with significant ostial disease length are considered by expert consensus to warrant a 2-stent technique upfront. This consensus view has not been scientifically assessed. Symptomatic patients with large caliber true bifurcation lesions (SB diameter ≥2.5 mm) and significant ostial disease length (≥5 mm) were randomized to either a provisional T-stent strategy or a dual stent culotte technique. Two hundred patients aged 64±10 years, 82% male, were randomized in 20 European centers. The clinical presentations were stable coronary disease (69%) and acute coronary syndromes (31%). SB stent diameter (2.67±0.27 mm) and length (20.30±5.89 mm) confirmed the extent of SB disease. Procedural success (provisional 97%, culotte 94%) and kissing balloon inflation (provisional 95%, culotte 98%) were high. Sixteen percent of patients in the provisional group underwent T-stenting. The primary end point (a composite of death, myocardial infarction, and target vessel revascularization at 12 months) occurred in 7.7% of the provisional T-stent group versus 10.3% of the culotte group (hazard ratio, 1.02; 95% confidence interval, 0.78-1.34; P=0.53). Procedure time, x-ray dose, and cost all favored the simpler procedure. When treating complex coronary bifurcation lesions with large stenosed SBs, there is no difference between a provisional T-stent strategy and a systematic 2-stent culotte strategy in a composite end point of death, myocardial infarction, and target vessel revascularization at 12 months. URL: http://www.clinicaltrials.gov. Unique identifier: NCT 01560455. © 2016 American Heart Association, Inc.

  7. Prosthetic valve endocarditis caused by Bordetella holmesii, an Acinetobacter lookalike.

    Science.gov (United States)

    Jonckheere, Stijn; De Baere, Thierry; Schroeyers, Pascal; Soetens, Oriane; De Bel, Annelies; Surmont, Ignace

    2012-06-01

    We report a case of fulminant endocarditis on a prosthetic homograft aortic valve caused by Bordetella holmesii, which was successfully managed by surgical valve replacement and antibiotic treatment. B. holmesii, a strictly aerobic, small, Gram-negative coccobacillus, has been implicated as an infrequent cause of a pertussis-like syndrome and other respiratory illnesses. However, B. holmesii is also a rare cause of septicaemia and infective endocarditis, mostly in immunocompromised patients. To our knowledge, this is the first report of B. holmesii endocarditis on a prosthetic aortic valve. Routine laboratory testing initially misidentified the strain as Acinetobacter sp. Correct identification was achieved by 16S rRNA gene and outer-membrane protein A (ompA) gene sequencing. Interestingly, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry also produced an accurate species-level identification. Subsequent susceptibility testing and review of the literature revealed ceftazidime, cefepime, carbapenems, aminoglycosides, fluoroquinolones, piperacillin/tazobactam, tigecycline and colistin as possible candidates to treat infections caused by B. holmesii.

  8. Prosthetic vision: devices, patient outcomes and retinal research.

    Science.gov (United States)

    Hadjinicolaou, Alex E; Meffin, Hamish; Maturana, Matias I; Cloherty, Shaun L; Ibbotson, Michael R

    2015-09-01

    Retinal disease and its associated retinal degeneration can lead to the loss of photoreceptors and therefore, profound blindness. While retinal degeneration destroys the photoreceptors, the neural circuits that convey information from the eye to the brain are sufficiently preserved to make it possible to restore sight using prosthetic devices. Typically, these devices consist of a digital camera and an implantable neurostimulator. The image sensor in a digital camera has the same spatiotopic arrangement as the photoreceptors of the retina. Therefore, it is possible to extract meaningful spatial information from an image and deliver it via an array of stimulating electrodes directly to the surviving retinal circuits. Here, we review the structure and function of normal and degenerate retina. The different approaches to prosthetic implant design are described in the context of human and preclinical trials. In the last section, we review studies of electrical properties of the retina and its response to electrical stimulation. These types of investigation are currently assessing a number of key challenges identified in human trials, including stimulation efficacy, spatial localisation, desensitisation to repetitive stimulation and selective activation of retinal cell populations. © 2015 The Authors. Clinical and Experimental Optometry © 2015 Optometry Australia.

  9. New prosthetic restorative features of Ankylos implant system.

    Science.gov (United States)

    Weigl, Paul

    2004-01-01

    All oral implant systems rely on the abutment part of the implant to provide stability for the dental prosthetic. The Ankylos implant offers precisely machined, tapered-cone abutment (Morse taper) connection. This tapered abutment connection provides high resistance to bending and rotational torque during clinical function, which significantly reduces the possibilities of screw fracture or loosening. This report describes the design and mechanical construction characteristics of the Ankylos implant system that make it possible for the system to provide final restorations that are natural looking, esthetically acceptable, durable, and cost effective. Review of the clinical literature. The clinical results of singletooth crowns borne on Ankylos implants in the lateral tooth region are excellent after a minimum of 5 years in function (mean = 6.3 years) compared with the high prosthetic complication rate with other systems. Abutment loosening occurred in only 1.3% of the 233 innovative implants restored with crowns that were designed with a physiologically shaped occlusal surface. This implant system is exceptionally well suited for use in the restoration of missing natural teeth.

  10. Case Report. Prosthetic Rehabilitation of Crowded Maxillary Anterior Teeth

    Directory of Open Access Journals (Sweden)

    Markovics Emese Rita

    2017-03-01

    Full Text Available In this case report we present the aesthetical correction of crowded anterior teeth in a patient who has refused the orthodontic treatment. We also discuss how this correction can be resolved from the point of view of dental prosthetic and what measurements can be helpful in order to collect the data used to restore a satisfying smile on the patient’s face using dental ceramic restoration. Case presentation: A 32-year-old patient complained about his crowded incisors. We examined the incisal curvature, the proportion between the height and the width of the teeth, and the relation between the widths of the teeth and the golden proportion. The results of the measurements were compared to the characteristic values of the ideal denture. After the examination of the dental plaster cast, calculating the difference between the existing space and the necessary space, we were able to calculate the lack of space, which caused the crowded teeth. Conclusion: Along the prosthetic planning, these measurements may serve as a guideline to the dentist as an objective basis for the formation of an aesthetic denture and smile.

  11. Consumer satisfaction with the services of prosthetics and orthotics facilities.

    Science.gov (United States)

    Bosmans, Joline; Geertzen, Jan; Dijkstra, Pieter U

    2009-03-01

    Consumer satisfaction with the services provided in a prosthetics and orthotics (P&O) facility has seldom been studied. The aim of this study was to analyze consumer satisfaction regarding the services provided by 15 P&O facilities in The Netherlands. Consumers (n = 1,364) of these P&O facilities who were fitted with a prosthesis, orthopaedic shoes, an orthosis, or another device, were asked to rate the overall services provided and whether they were satisfied with the device provided and its delivery time. Additionally, they filled in a modified SERVQUAL questionnaire (see Appendix). Consumers gave the service provided by P&O facilities a mean overall rating of 8.1. The highest ratings were given by consumers fitted with a prosthesis (mean overall rating of services: 8.4). In total, 78% of the consumers were satisfied with the device provided and 93% with the delivery time. The results of our study showed that, on the SERVQUAL, 50% of the statements fulfilled the criteria for a satisfactory quality of the services. The overall consumer rating of the service provided by P&O facilities is high and depends on the device provided. The outcomes on the SERVQUAL were moderate. In future, it is important to study consumer satisfaction more extensively in order to improve the quality of P&O services in daily practice. Additionally, specific questionnaires need to be developed to measure all aspects of prosthetic and orthotic care, with the aim to improve the services.

  12. Prosthetic replacement of the infrahepatic inferior vena cava for leiomyosarcoma.

    Science.gov (United States)

    Illuminati, Giulio; Calio', Francesco G; D'Urso, Antonio; Giacobbi, Daniela; Papaspyropoulos, Vassilios; Ceccanei, Gianluca

    2006-09-01

    Resection of the infrahepatic inferior vena cava associated with prosthetic graft replacement for caval leiomyosarcoma is an acceptable procedure to obtain prolonged and good-quality survival. A consecutive sample clinical study with a mean follow-up of 40 months. The surgical department of an academic tertiary center and an affiliated secondary care center. Eleven patients, with a mean age of 51 years, who have primary leiomyosarcoma of the infrahepatic inferior vena cava. All of the patients underwent radical resection of the tumor en bloc with the affected segment of the vena cava. Reconstruction consisted of 10 cavocaval polytetrafluoroethylene grafts and 1 cavobiliac graft. An associated right nephrectomy was performed in 2 cases. The left renal vein was reimplanted in the graft in 3 cases. Cumulative disease-specific survival, disease-free survival, and graft patency rates expressed by standard life-table analysis. No patients died in the postoperative period. The cumulative (SE) disease-specific survival rate was 53% (21%) at 5 years. The cumulative (SE) disease-free survival rate was 44% (19%) at 5 years. The cumulative (SE) graft patency rate was 67% (22%) at 5 years. Radical resection followed by prosthetic graft reconstruction is a valuable method for treating primary leiomyosarcoma of the infrahepatic inferior vena cava.

  13. [Streptococcus equisimilis associated septic arthritis/prosthetic joint infection].

    Science.gov (United States)

    Sipahi, Oğuz Reşat; Ozkören Calik, Sebnem; Pullukçu, Hüsnü; Işikgöz Taşbakan, Meltem; Arda, Bilgin; Tünger, Alper; Ulusoy, Sercan

    2008-07-01

    Group C streptococci are flora members of skin, nasopharynx, gastrointestinal and genitourinary systems. They are rare causes of human pharyngitis, arthritis, pneumonia, meningitis and bacteremia. In this report, a 71-years old male patient with Streptococcus equisimilis arthritis/prosthetic joint infection has been presented. The patient was admitted to the emergency service with the complaints of erythema, swelling and tenderness on right knee which had total knee prosthesis. Examination of synovial fluid punction sample yielded abundant amount of leukocytes (> 1000 cells/mm3). Empirical ampicillin-sulbactam (1 g q6h, parenterally) therapy was initiated. Bacteria which have been cultivated from synovial fluid specimen were identified as S. equisimilis. The isolate was found to be susceptible to penicilin, erythromycin and teicoplanin, and resistant to chloramphenicol and tetracycline. Although clinical presentation improved during the first ten days, symptoms recurred after the 10th day and the therapy was switched to teicoplanin. The recurrence was thought to be the result of antibiotic tolerence. The patient was treated successfully with teicoplanin, and no relapse or reinfection was observed during one year of follow-up. To our knowledge this is the first case of S. equisimilis arthritis reported from Turkey and first case of S. equisimilis associated prosthetic joint infection.

  14. Psychophysics of prosthetic vision: I. Visual scanning and visual acuity.

    Science.gov (United States)

    Chen, S C; Hallum, L E; Suaning, G J; Lovell, N H

    2006-01-01

    Recipients of vision prosthesis prototypes have reported electrically elicited visual perceptions as discrete dots of light (phosphenes). Phosphenes construct the scenery in discontinuous small isolated patches, resulting in visual information deficit to a large portion of the visual field. Visual scanning therefore plays an important role in the utility of prosthetic vision. In a psychophysical study, normally sighted subjects undertook a visual acuity task in a simulation of prosthetic vision with scanning facilitated by head movements. Subjects who adopted the circular scanning technique (4/12) correctly identified >60% of the test items, compared to subjects with no particular scanning patterns (3/12) with <50%. Increased head movement velocity was correlated to increased performance; at optimal scanning velocities, we estimated a 50% increase in identification rate or a two-fold improvement in visual acuity threshold compared to otherwise complete lack of scanning movement. Improved performance likely resulted from positive interactions with the temporal processes of the human visual system, which may as much as double the spatial information of that originally afforded by the phosphene lattice.

  15. A surface EMG test tool to measure proportional prosthetic control.

    Science.gov (United States)

    Sturma, Agnes; Roche, Aidan D; Göbel, Peter; Herceg, Malvina; Ge, Nan; Fialka-Moser, Veronika; Aszmann, Oskar

    2015-06-01

    In upper limb amputees, prosthetic control training is recommended before and after fitting. During rehabilitation, the focus is on selective proportional control signals. For functional monitoring, many different tests are available. None can be used in the early phase of training. However, an early assessment is needed to judge if a patient has the potential to control a certain prosthetic set-up. This early analysis will determine if further training is needed or if other strategies would be more appropriate. Presented here is a tool that is capable of predicting achievable function in voluntary EMG control. This tool is applicable to individual muscle groups to support preparation of training and fitting. In four of five patients, the sEMG test tool accurately predicted the suitability for further myoelectric training based on SHAP outcome measures. (P1: "Poor" function in the sEMG test tool corresponded to 54/100 in the SHAP test; P2: Good: 85; P3: Good: 81; P4: Average: 78). One patient scored well during sEMG testing, but was unmotivated during SHAP testing. (Good: 50) Therefore, the surface EMG test tool may predict achievable control skills to a high extent, validated with the SHAP, but requires further clinical testing to validate this technique.

  16. A powered prosthetic ankle joint for walking and running.

    Science.gov (United States)

    Grimmer, Martin; Holgate, Matthew; Holgate, Robert; Boehler, Alexander; Ward, Jeffrey; Hollander, Kevin; Sugar, Thomas; Seyfarth, André

    2016-12-19

    Current prosthetic ankle joints are designed either for walking or for running. In order to mimic the capabilities of an able-bodied, a powered prosthetic ankle for walking and running was designed. A powered system has the potential to reduce the limitations in range of motion and positive work output of passive walking and running feet. To perform the experiments a controller capable of transitions between standing, walking, and running with speed adaptations was developed. In the first case study the system was mounted on an ankle bypass in parallel with the foot of a non-amputee subject. By this method the functionality of hardware and controller was proven. The Walk-Run ankle was capable of mimicking desired torque and angle trajectories in walking and running up to 2.6 m/s. At 4 m/s running, ankle angle could be matched while ankle torque could not. Limited ankle output power resulting from a suboptimal spring stiffness value was identified as a main reason. Further studies have to show to what extent the findings can be transferred to amputees.

  17. The Prosthetic Influence and Biomechanics on Peri-Implant Strain: a Systematic Literature Review of Finite Element Studies

    Directory of Open Access Journals (Sweden)

    Julius Maminskas

    2016-09-01

    Full Text Available Objectives: To systematically review risks of mechanical impact on peri-implant strain and prosthetic influence on stability across finite element studies. Material and Methods: An online literature search was performed on MEDLINE and EMBASE databases published between 2011 and 2016. Following keywords tiered screening and selection of the title, abstract and full-text were performed. Studies of finite element analysis (FEA were considered for inclusion that were written in English and revealed stress concentrations or strain at peri-implant bone level. Results: There were included 20 FEA studies in total. Data were organized according to the following topics: bone layers, type of bone, osseointegration level, bone level, design of implant, diameter and length of implant, implant-abutment connection, type of supra-construction, loading axis, measurement units. The stress or strain at implant-bone contact was measured over all studies and numerical values estimated. Risks of overloading were accented as non-axial loading, misfits, cantilevers and the stability of peri-implant bone was related with the usage of platform switch connection of abutment. Conclusions: Peri-implant area could be affected by non-axial loading, cantilever prosthetic elements, crown/implant ratio, type of implant-abutment connection, misfits, properties of restoration materials and antagonistic tooth. The heterogeneity of finite element analysis studies limits systematization of data. Results of these studies are comparable with other findings of in vitro, in vivo, prospective and retrospective studies.

  18. Mechanical design and performance specifications of anthropomorphic prosthetic hands: a review.

    Science.gov (United States)

    Belter, Joseph T; Segil, Jacob L; Dollar, Aaron M; Weir, Richard F

    2013-01-01

    In this article, we set forth a detailed analysis of the mechanical characteristics of anthropomorphic prosthetic hands. We report on an empirical study concerning the performance of several commercially available myoelectric prosthetic hands, including the Vincent, iLimb, iLimb Pulse, Bebionic, Bebionic v2, and Michelangelo hands. We investigated the finger design and kinematics, mechanical joint coupling, and actuation methods of these commercial prosthetic hands. The empirical findings are supplemented with a compilation of published data on both commercial and prototype research prosthetic hands. We discuss numerous mechanical design parameters by referencing examples in the literature. Crucial design trade-offs are highlighted, including number of actuators and hand complexity, hand weight, and grasp force. Finally, we offer a set of rules of thumb regarding the mechanical design of anthropomorphic prosthetic hands.

  19. Distal anastomotic vein adjunct usage in infrainguinal prosthetic bypasses.

    Science.gov (United States)

    McPhee, James T; Goodney, Philip P; Schanzer, Andres; Shaykevich, Shimon; Belkin, Michael; Menard, Matthew T

    2013-04-01

    Single-segment saphenous vein remains the optimal conduit for infrainguinal revascularization. In its absence, prosthetic conduit may be used. Existing data regarding the significance of anastomotic distal vein adjunct (DVA) usage with prosthetic grafts are based on small series. This is a retrospective cohort analysis derived from the regional Vascular Study Group of New England as well as the Brigham and Women's hospital database. A total of 1018 infrainguinal prosthetic bypass grafts were captured in the dataset from 73 surgeons at 15 participating institutions. Propensity scoring and 3:1 matching was performed to create similar exposure groups for analysis. Outcome measures of interest included: primary patency, freedom from major adverse limb events (MALEs), and amputation free survival at 1 year as a function of vein patch utilization. Time to event data were compared with the log-rank test; multivariable Cox proportional hazard models were used to evaluate the adjusted association between vein cuff usage and the primary end points. DVA was defined as a vein patch, cuff, or boot in any configuration. Of the 1018 bypass operations, 94 (9.2%) had a DVA whereas 924 (90.8%) did not (no DVA). After propensity score matching, 88 DVAs (25%) and 264 no DVAs (75%) were analyzed. On univariate analysis of the matched cohort, the DVA and no DVA groups were similar in terms of mean age (70.0 vs 69.0; P = .55), male sex (58.0% vs 58.3%; P > .99), and preoperative characteristics such as living at home (93.2% vs 94.3%; P = .79) and independent ambulatory status (72.7% vs 75.7%; P = .64). The DVA and no DVA groups had similar rates of major comorbidities such as hypertension chronic obstructive pulmonary disease, diabetes mellitus, coronary artery disease, and dialysis dependence (P > .05 for all). Likewise, they had similar rates of distal origin grafts (13.6% vs 12.5%; P = .85), critical limb ischemia indications (P = .53), and prior arterial bypass (58% vs 47%; P = .08

  20. Prosthetic valves in adult patients with congenital heart disease : Rationale and design of the Dutch PROSTAVA study

    NARCIS (Netherlands)

    Freling, H. G.; van Slooten, Y. J.; van Melle, J. P.; Mulder, B. J. M.; van Dijk, A. P. J.; Hillege, H. L.; Post, M. C.; Sieswerda, G. Tj; Jongbloed, M. R. M.; Willems, T. P.; Pieper, P. G.

    2012-01-01

    Data on long-term complications in adult patients with congenital heart disease (ACHD) and a prosthetic valve are scarce. Moreover, the influence of prosthetic valves on quality of life (QoL) and functional outcome in ACHD patients with prosthetic valves has not been studied. The primary objective

  1. Developing a provisional, international minimal dataset for Juvenile Dermatomyositis: for use in clinical practice to inform research.

    Science.gov (United States)

    McCann, Liza J; Arnold, Katie; Pilkington, Clarissa A; Huber, Adam M; Ravelli, Angelo; Beard, Laura; Beresford, Michael W; Wedderburn, Lucy R

    2014-01-01

    Juvenile dermatomyositis (JDM) is a rare but severe autoimmune inflammatory myositis of childhood. International collaboration is essential in order to undertake clinical trials, understand the disease and improve long-term outcome. The aim of this study was to propose from existing collaborative initiatives a preliminary minimal dataset for JDM. This will form the basis of the future development of an international consensus-approved minimum core dataset to be used both in clinical care and inform research, allowing integration of data between centres. A working group of internationally-representative JDM experts was formed to develop a provisional minimal dataset. Clinical and laboratory variables contained within current national and international collaborative databases of patients with idiopathic inflammatory myopathies were scrutinised. Judgements were informed by published literature and a more detailed analysis of the Juvenile Dermatomyositis Cohort Biomarker Study and Repository, UK and Ireland. A provisional minimal JDM dataset has been produced, with an associated glossary of definitions. The provisional minimal dataset will request information at time of patient diagnosis and during on-going prospective follow up. At time of patient diagnosis, information will be requested on patient demographics, diagnostic criteria and treatments given prior to diagnosis. During on-going prospective follow-up, variables will include the presence of active muscle or skin disease, major organ involvement or constitutional symptoms, investigations, treatment, physician global assessments and patient reported outcome measures. An internationally agreed minimal dataset has the potential to significantly enhance collaboration, allow effective communication between groups, provide a minimal standard of care and enable analysis of the largest possible number of JDM patients to provide a greater understanding of this disease. This preliminary dataset can now be developed into

  2. A provisional regulatory gene network for specification of endomesoderm in the sea urchin embryo

    Science.gov (United States)

    Davidson, Eric H.; Rast, Jonathan P.; Oliveri, Paola; Ransick, Andrew; Calestani, Cristina; Yuh, Chiou-Hwa; Minokawa, Takuya; Amore, Gabriele; Hinman, Veronica; Arenas-Mena, Cesar; hide

    2002-01-01

    We present the current form of a provisional DNA sequence-based regulatory gene network that explains in outline how endomesodermal specification in the sea urchin embryo is controlled. The model of the network is in a continuous process of revision and growth as new genes are added and new experimental results become available; see http://www.its.caltech.edu/mirsky/endomeso.htm (End-mes Gene Network Update) for the latest version. The network contains over 40 genes at present, many newly uncovered in the course of this work, and most encoding DNA-binding transcriptional regulatory factors. The architecture of the network was approached initially by construction of a logic model that integrated the extensive experimental evidence now available on endomesoderm specification. The internal linkages between genes in the network have been determined functionally, by measurement of the effects of regulatory perturbations on the expression of all relevant genes in the network. Five kinds of perturbation have been applied: (1) use of morpholino antisense oligonucleotides targeted to many of the key regulatory genes in the network; (2) transformation of other regulatory factors into dominant repressors by construction of Engrailed repressor domain fusions; (3) ectopic expression of given regulatory factors, from genetic expression constructs and from injected mRNAs; (4) blockade of the beta-catenin/Tcf pathway by introduction of mRNA encoding the intracellular domain of cadherin; and (5) blockade of the Notch signaling pathway by introduction of mRNA encoding the extracellular domain of the Notch receptor. The network model predicts the cis-regulatory inputs that link each gene into the network. Therefore, its architecture is testable by cis-regulatory analysis. Strongylocentrotus purpuratus and Lytechinus variegatus genomic BAC recombinants that include a large number of the genes in the network have been sequenced and annotated. Tests of the cis-regulatory predictions of

  3. Provisional in-silico biopharmaceutics classification (BCS to guide oral drug product development

    Directory of Open Access Journals (Sweden)

    Wolk O

    2014-09-01

    Full Text Available Omri Wolk, Riad Agbaria, Arik Dahan Department of Clinical Pharmacology, School of Pharmacy, Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva, Israel Abstract: The main objective of this work was to investigate in-silico predictions of physicochemical properties, in order to guide oral drug development by provisional biopharmaceutics classification system (BCS. Four in-silico methods were used to estimate LogP: group contribution (CLogP using two different software programs, atom contribution (ALogP, and element contribution (KLogP. The correlations (r2 of CLogP, ALogP and KLogP versus measured LogP data were 0.97, 0.82, and 0.71, respectively. The classification of drugs with reported intestinal permeability in humans was correct for 64.3%–72.4% of the 29 drugs on the dataset, and for 81.82%–90.91% of the 22 drugs that are passively absorbed using the different in-silico algorithms. Similar permeability classification was obtained with the various in-silico methods. The in-silico calculations, along with experimental melting points, were then incorporated into a thermodynamic equation for solubility estimations that largely matched the reference solubility values. It was revealed that the effect of melting point on the solubility is minor compared to the partition coefficient, and an average melting point (162.7°C could replace the experimental values, with similar results. The in-silico methods classified 20.76% (±3.07% as Class 1, 41.51% (±3.32% as Class 2, 30.49% (±4.47% as Class 3, and 6.27% (±4.39% as Class 4. In conclusion, in-silico methods can be used for BCS classification of drugs in early development, from merely their molecular formula and without foreknowledge of their chemical structure, which will allow for the improved selection, engineering, and developability of candidates. These in-silico methods could enhance success rates, reduce costs, and accelerate oral drug products development

  4. Provisional clinical chemistry parameters in the African Sharptooth catfish (Clarias gariepinus

    Directory of Open Access Journals (Sweden)

    J.G. Myburgh

    2008-05-01

    Full Text Available This is a reprint of Myburgh, J.G. Botha, C.J. Booyse, D.G. & Reyers, F., 2008, 'Provisional clinical chemistry parameters in the African Sharptooth catfish (Clarias gariepinus', Journal of the South African Veterinary Association 79(4, 156-160. http://dx.doi.org/10.4102/jsava.v79i4.265:Pollution affects aquatic systems worldwide and there is an urgent need for efficient monitoring. Fish are generally sensitive to their environment and are thus considered to be valuable bioindicator species. The African Sharptooth catfish (Clarias gariepinus is particularly important in this respect because of its very wide distribution. In order to use C. gariepinus as a bioindicator species its baseline clinical chemistry must be defined. Existing data are scarce, and the objective of this work was therefore to establish clinical chemistry parameters for C. gariepinus. Blood was collected from male and female catfish and a number of clinical chemistry parameters were determined. Plasma protein values, but particularly those of plasma albumin, were found to be very low, approximately half the value for dogs, but similar to the values in Channel catfish (Ictalurus punctatus. Plasma urea values in Sharptooth catfish were found to be much lower than in dogs, but only marginally lower than in Channel catfish. Plasma creatinine in Sharptooth catfish, however, was only a quarter of that of dogs and one third of that found in Channel catfish. These findings may have implications for using urea and / or creatinine as an index of renal glomerular filtration, as is done in mammals. Plasma enzyme activity ranges were much lower in Sharptooth catfish than in dogs, particularly for alkaline phosphatase (ALP and alanine aminotransferase (ALT. By comparison, Channel catfish have an even lower ALT activity range but an ALP range that is very similar to dogs. The implications for using these enzymes as markers for liver disease are not clear from these data, as factors such as

  5. Esthetic Outcome of Implant Supported Crowns With and Without Peri-Implant Conditioning Using Provisional Fixed Prosthesis: A Randomized Controlled Clinical Trial.

    Science.gov (United States)

    Furze, David; Byrne, Ashley; Alam, Sonia; Wittneben, Julia-Gabriela

    2016-12-01

    Achieving an optimal esthetic result using dental implants is challenging. Fixed implant-supported provisional crowns are often used to customize the emergence profile and to individualize the surrounding peri-implant soft tissue. The objective of this study is to evaluate whether the use of a provisional implant-supported crown leads to an esthetic benefit on implants that are placed in the esthetic zone. The null hypothesis is that there is no-difference between the two study groups. Twenty single implants (Bone Level, Straumann AG, Basel, Switzerland) were inserted in consecutive patients. After reopening, a randomization process assigned them to either cohort group 1: a provisional phase with soft tissue conditioning using the "dynamic compression technique" or cohort group 2: without a provisional. Implants were finally restored with an all-ceramic crown. Follow-up examinations were performed at 3 and 12 months including implant success and survival, clinical, and radiographic parameters. After 1 year all implants successfully integrated, mean values of combined modPES and WES were 16.7 for group 1 and 10.5 for Group 2. This was statistically significant. Mean bone loss after 1 year was -0.09 and -0.08 for groups 1 and 2, respectively, without being statistically significant. A provisional phase with soft tissue conditioning does improve the final esthetic result. © 2016 Wiley Periodicals, Inc.

  6. Parametric optimization and design validation based on finite element analysis of hybrid socket adapter for transfemoral prosthetic knee.

    Science.gov (United States)

    Kumar, Neelesh

    2014-10-01

    Finite element analysis has been universally employed for the stress and strain analysis in lower extremity prosthetics. The socket adapter was the principal subject of interest due to its importance in deciding the knee motion range. This article focused on the static and dynamic stress analysis of the designed hybrid adapter developed by the authors. A standard mechanical design validation approach using von Mises was followed. Four materials were considered for the analysis, namely, carbon fiber, oil-filled nylon, Al-6061, and mild steel. The paper analyses the static and dynamic stress on designed hybrid adapter which incorporates features of conventional male and female socket adapters. The finite element analysis was carried out for possible different angles of knee flexion simulating static and dynamic gait situation. Research was carried out on available design of socket adapter. Mechanical design of hybrid adapter was conceptualized and a CAD model was generated using Inventor modelling software. Static and dynamic stress analysis was carried out on different materials for optimization. The finite element analysis was carried out on the software Autodesk Inventor Professional Ver. 2011. The peak value of von Mises stress occurred in the neck region of the adapter and in the lower face region at rod eye-adapter junction in static and dynamic analyses, respectively. Oil-filled nylon was found to be the best material among the four with respect to strength, weight, and cost. Research investigations on newer materials for development of improved prosthesis will immensely benefit the amputees. The study analyze the static and dynamic stress on the knee joint adapter to provide better material used for hybrid design of adapter. © The International Society for Prosthetics and Orthotics 2013.

  7. Prosthetic joint infections: radionuclide state-of-the-art imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gemmel, Filip [AZ Alma Campus Sijsele, Department of Nuclear Medicine, Sijsele-Damme (Belgium); Wyngaert, Hans van den [AZ Alma Campus Sijsele, Department of Orthopaedic Surgery, Sijsele-Damme (Belgium); Love, Charito [Albert Einstein College of Medicine of Yeshiva University, Division of Nuclear Medicine and Radiology, Bronx, NY (United States); Welling, M.M. [Leiden University Medical Center, Scientist Molecular Imaging, Department of Radiology, Section of Nuclear Medicine C2-203, Leiden (Netherlands); Gemmel, Paul [Ghent University, The Faculty of Economics and Business Administration, Ghent (Belgium); Palestro, Christopher J. [Hofstra North Shore-Long Island Jewish Health System, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Hempstead, NY (United States)

    2012-05-15

    Prosthetic joint replacement surgery is performed with increasing frequency. Overall the incidence of prosthetic joint infection (PJI) and subsequently prosthesis revision failure is estimated to be between 1 and 3%. Differentiating infection from aseptic mechanical loosening, which is the most common cause of prosthetic failure, is especially important because of different types of therapeutic management. Despite a thorough patient history, physical examination, multiple diagnostic tests and complex algorithms, differentiating PJI from aseptic loosening remains challenging. Among imaging modalities, radiographs are neither sensitive nor specific and cross-sectional imaging techniques, such as computed tomography and magnetic resonance imaging, are limited by hardware-induced artefacts. Radionuclide imaging reflects functional rather than anatomical changes and is not hampered by the presence of a metallic joint prosthesis. As a result scintigraphy is currently the modality of choice in the investigation of suspected PJI. Unfortunately, there is no true consensus about the gold standard technique since there are several drawbacks and limitations inherent to each modality. Bone scintigraphy (BS) is sensitive for identifying the failed joint replacement, but cannot differentiate between infection and aseptic loosening. Combined bone/gallium scintigraphy (BS/GS) offers modest improvement over BS alone for diagnosing PJI. However, due to a number of drawbacks, BS/GS has generally been superseded by other techniques but it still may have a role in neutropenic patients. Radiolabelled leucocyte scintigraphy remains the gold standard technique for diagnosing neutrophil-mediated processes. It seems to be that combined in vitro labelled leucocyte/bone marrow scintigraphy (LS/BMS), with an accuracy of about 90%, is currently the imaging modality of choice for diagnosing PJI. There are, however, significant limitations using in vitro labelled leucocytes and considerable effort

  8. A 3D velocimetry study of the flow through prosthetic heart valves

    Science.gov (United States)

    Ledesma, R.; Zenit, R.; Pulos, G.; Sanchez, E.; Juarez, A.

    2006-11-01

    Blood damage commonly appears in medical valve prothesis. It is a mayor concern for the designers and surgeons. It is well known that this damage and other complications result from the modified fluid dynamics through the replacement valve. To evaluate the performance of prosthetic heart valves, it is necessary to study the flow through them. To conduct this study , we have built a flow channel that emulates cardiac conditions and allows optical access such that a 3D-PIV velocimetry system could be used. The experiments are aimed to reconstruct the downstream structure of the flow through a mechanical and a bio-material tricuspid heart valve prothesis. Preliminary results show that the observed coherent structures can be related with haemolysis and trombosis, illnesses commonly found in valve prothesis recipients. The mean flow, the levels of strain rate and the turbulence intensity generated by the valves can also be directly related to blood damage. In general, bio-material made valves tend to reduce these complications.

  9. Modeling and stress analyses of a normal foot-ankle and a prosthetic foot-ankle complex.

    Science.gov (United States)

    Ozen, Mustafa; Sayman, Onur; Havitcioglu, Hasan

    2013-01-01

    Total ankle replacement (TAR) is a relatively new concept and is becoming more popular for treatment of ankle arthritis and fractures. Because of the high costs and difficulties of experimental studies, the developments of TAR prostheses are progressing very slowly. For this reason, the medical imaging techniques such as CT, and MR have become more and more useful. The finite element method (FEM) is a widely used technique to estimate the mechanical behaviors of materials and structures in engineering applications. FEM has also been increasingly applied to biomechanical analyses of human bones, tissues and organs, thanks to the development of both the computing capabilities and the medical imaging techniques. 3-D finite element models of the human foot and ankle from reconstruction of MR and CT images have been investigated by some authors. In this study, data of geometries (used in modeling) of a normal and a prosthetic foot and ankle were obtained from a 3D reconstruction of CT images. The segmentation software, MIMICS was used to generate the 3D images of the bony structures, soft tissues and components of prosthesis of normal and prosthetic ankle-foot complex. Except the spaces between the adjacent surface of the phalanges fused, metatarsals, cuneiforms, cuboid, navicular, talus and calcaneus bones, soft tissues and components of prosthesis were independently developed to form foot and ankle complex. SOLIDWORKS program was used to form the boundary surfaces of all model components and then the solid models were obtained from these boundary surfaces. Finite element analyses software, ABAQUS was used to perform the numerical stress analyses of these models for balanced standing position. Plantar pressure and von Mises stress distributions of the normal and prosthetic ankles were compared with each other. There was a peak pressure increase at the 4th metatarsal, first metatarsal and talus bones and a decrease at the intermediate cuneiform and calcaneus bones, in

  10. Impact testing of the residual limb: System response to changes in prosthetic stiffness.

    Science.gov (United States)

    Boutwell, Erin; Stine, Rebecca; Gard, Steven

    2016-01-01

    Currently, it is unknown whether changing prosthetic limb stiffness affects the total limb stiffness and influences the shock absorption of an individual with transtibial amputation. The hypotheses tested within this study are that a decrease in longitudinal prosthetic stiffness will produce (1) a reduced total limb stiffness, and (2) reduced magnitude of peak impact forces and increased time delay to peak force. Fourteen subjects with a transtibial amputation participated in this study. Prosthetic stiffness was modified by means of a shock-absorbing pylon that provides reduced longitudinal stiffness through compression of a helical spring within the pylon. A sudden loading evaluation device was built to examine changes in limb loading mechanics during a sudden impact event. No significant change was found in the peak force magnitude or timing of the peak force between prosthetic limb stiffness conditions. Total limb stiffness estimates ranged from 14.9 to 17.9 kN/m but were not significantly different between conditions. Thus, the prosthetic-side total limb stiffness was unaffected by changes in prosthetic limb stiffness. The insensitivity of the total limb stiffness to prosthetic stiffness may be explained by the mechanical characteristics (i.e., stiffness and damping) of the anatomical tissue within the residual limb.

  11. Optimising the trans-femoral prosthetic alignment for running, by lowering the knee joint.

    Science.gov (United States)

    Burkett, B; Smeathers, J; Barker, T

    2001-12-01

    For amputees to perform an everyday task, or to participate in physical exercise, it is crucial that they have an appropriately designed functional prosthesis. The aim of this study was to investigate the optimal trans-femoral prosthetic alignment configuration for running. A case study design was implemented as the method to collect data on four male Paralympic level trans-femoral amputee runners. In total 28 synchronised 3D kinematic, kinetic, and temporal biomechanical measures were analysed. A new prosthetic alignment, in which the prosthetic knee axis was lowered longitudinally (moved distally), was evaluated for running. The performance of the symmetry indices and running time for a total of three new modified alignments were compared to the standard prosthetic alignment. The interlimb asymmetry was found to improve when the subjects ran on the modified prosthetic alignment, and most importantly a one way ANOVA found a statistically significant increase in running velocity. This study identified that for all four subjects, who used the same prosthetic components, lowering the prosthetic knee joint centre improved their interlimb symmetry, and subsequently their running velocity by an average of 26%.

  12. PERSPECTIVE: Consideration of user priorities when developing neural prosthetics

    Science.gov (United States)

    Anderson, Kim D.

    2009-10-01

    For too long there has been separation of basic science, biomedical engineering, clinical science and the people these disciplines are serving. A key ingredient to understanding the real-life consequences of many neurologic disorders that produce physical disabilities, such as spinal cord injury, is to obtain valuable information from the individuals that are actually living with the disorders everyday. This information can be obtained in an objective and usable format, which can then be used to direct biomedical research in a manner that is meaningful to the intended beneficiaries. In particular, the field of neural prosthetics for spinal cord injury can make great strides if user input is obtained throughout the stages of development. Presented here is the perspective of a scientist who also has 20 years of experience living with a cervical spinal cord injury.

  13. Prosthetic Correction of Postenucleation Socket Syndrome: A Case Report.

    Science.gov (United States)

    Kamble, Vikas B

    2014-12-01

    Postenucleation socket syndrome is a frequent late complication of enucleation of eye globe. Several pathophysiological mechanisms have been proposed to account for the symptoms of postenucleation socket syndrome, which include lost orbital volume, superior sulcus deformity, upper eyelid ptosis, lower eyelid laxity, and backward tilt of the prosthesis. The goal of postenucleation socket syndrome treatment is to achieve the best possible functional and esthetic result. The treatment can be either conservative or surgical. For the patient interested in a non-surgical correction, the conservative treatment is simple and non invasive and can be done with prosthesis modification for good positioning, comfort, and mobility. This paper describes prosthetic correction of a patient with postenucleation socket syndrome by modified ocular prosthesis.

  14. Adapting proportional myoelectric-controlled interfaces for prosthetic hands.

    Science.gov (United States)

    Pistohl, Tobias; Cipriani, Christian; Jackson, Andrew; Nazarpour, Kianoush

    2013-01-01

    Powered hand prostheses with many degrees of freedom are moving from research into the market for prosthetics. In order to make use of the prostheses' full functionality, it is essential to find efficient ways to control their multiple actuators. Human subjects can rapidly learn to employ electromyographic (EMG) activity of several hand and arm muscles to control the position of a cursor on a computer screen, even if the muscle-cursor map contradicts directions in which the muscles would act naturally. We investigated whether a similar control scheme, using signals from four hand muscles, could be adopted for real-time operation of a dexterous robotic hand. Despite different mapping strategies, learning to control the robotic hand over time was surprisingly similar to the learning of two-dimensional cursor control.

  15. Design of smart prosthetic knee utilizing magnetorheological damper

    Science.gov (United States)

    Gao, F.; Liu, Y. N.; Liao, W. H.

    2017-04-01

    In this study, based on human knee's kinetics, a smart prosthetic knee employing springs, DC motor and magnetorheological (MR) damper is designed. The MR damper is coupled in series with the springs that are mounted in parallel with the DC motor. The working principle of the prosthesis during level-ground walking is presented. During stance phase, the MR damper is powered on. The springs will store and release the negative mechanical energy for restoring the function of human knee joint. In swing phase, the MR damper is powered off for disengaging the springs. In this phase, the work of knee joint is negative. For improving the system energy efficiency, the DC motor will work as a power generator to supply required damping torque and harvest electrical energy. Finally, the design of MR damper is introduced.

  16. Custom design in lower limb prosthetics for athletic activity.

    Science.gov (United States)

    Fergason, J R; Boone, D A

    2000-08-01

    In summary, the prosthetist is the best source of information with regard to the fast-changing lower extremity prosthetics technology for sports. The needs and desires of the amputee should be outlined and balanced with the cost of the desired components and design. In many cases, one carefully designed prosthesis can serve in dual roles for everyday ambulation and certain athletic activities. In other cases, the amputee is limited severely by a prosthesis that is not designed for a specific activity. Using a prosthesis for activities that it was not designed to accommodate can cause physical injury to the amputee as well as structural failure of the device. A properly designed and fitted prosthesis can open a whole new world of activity to the amputee and helps him or her to reach the desired a vocational goals.

  17. Stenotrophomonas maltophilia prosthetic valve endocarditis: a case report

    Directory of Open Access Journals (Sweden)

    Bayle Sophie

    2008-05-01

    Full Text Available Abstract Introduction Stenotrophomonas maltophilia is an environmental bacterium increasingly involved in nosocomial infections and resistant to most antibiotics. It is important to recognize and efficiently treat infections with this bacterium as soon as possible. Case presentation We present a case of Stenotrophomonas maltophilia prosthetic valve endocarditis secondary to an indwelling catheter infection. The patient was cured without surgery. We review other cases of S. maltophilia endocarditis from the literature and describe the peculiarities of this case. Conclusion S. maltophilia endocarditis is a rare disease that is often hospital-acquired and related to an indwelling catheter infection. The high lethality is likely related to the intrinsic resistance of nosocomial bloodstream infections to commonly prescribed antibiotics.

  18. Prosthetic management of a patient with Treacher Collins syndrome

    Directory of Open Access Journals (Sweden)

    Madhan R

    2006-01-01

    Full Text Available Treacher Collins syndrome encompasses a group of closely related defects of the head and neck. It is a rare syndrome characterized by bilaterally symmetrical abnormalities derived from the first and second brachial arches and the nasal placode. It is an autosomal dominant disorder and its occurence ranges from 1 in 25,000 to 1 in 50,000 live births. The facial appearance of these patients can be improved by either surgical or prosthetic rehabilitation. In this case report we are presenting the features of a 13-year-old boy with Treacher Collins syndrome. A multidisplinary approach was followed in managing the situation. The various treatment options and the steps involved in making an auricular prosthesis are also discussed.

  19. The effect of recasting on corrosion of DUCINOX prosthetic alloy

    Directory of Open Access Journals (Sweden)

    L. Klimek

    2009-07-01

    Full Text Available The effect of recasting, up to two times, Ni-Cr (DUCINOX prosthetic alloy on its corrosion properties was carried out. The corrosion measurements were done in deoxygenated Fusayama Meyer artificial saliva solution at temperature of 37°C. In the study following electrochemical methods were used: measurement of free corrosion potential Ecor in open circuit, measurement of polarization resistance according to Stern-Geary's method and measurement of potentiodynamic characteristic in wide range of anodic polarization. In general, it can be stated that casting number weakly influence on corrosion properties of investigated alloy. At free corrosion potential there is no monotonic dependence of corrosion parameters versus casting number. However, at extreme anodic potentials monotonic changes of corrosion parameters with increasing casting number is observed. Obtained results and drawn conclusions are partially compatible with literature data.

  20. Undergraduate prosthetics and orthotics teaching methods: A baseline for international comparison.

    Science.gov (United States)

    Aminian, Gholamreza; O'Toole, John M; Mehraban, Afsoon Hassani

    2015-08-01

    Education of Prosthetics and Orthotics is a relatively recent professional program. While there has been some work on various teaching methods and strategies in international medical education, limited publication exists within prosthetics and orthotics. To identify the teaching and learning methods that are used in Bachelor-level prosthetics and orthotics programs that are given highest priority by expert prosthetics and orthotics instructors from regions enjoying a range of economic development. Mixed method. The study partly documented by this article utilized a mixed method approach (qualitative and quantitative methods) within which each phase provided data for other phases. It began with analysis of prosthetics and orthotics curricula documents, which was followed by a broad survey of instructors in this field and then a modified Delphi process. The expert instructors who participated in this study gave high priority to student-centered, small group methods that encourage critical thinking and may lead to lifelong learning. Instructors from more developed nations placed higher priority on student's independent acquisition of prosthetics and orthotics knowledge, particularly in clinical training. Application of student-centered approaches to prosthetics and orthotics programs may be preferred by many experts, but there appeared to be regional differences in the priority given to different teaching methods. The results of this study identify the methods of teaching that are preferred by expert prosthetics and orthotics instructors from a variety of regions. This treatment of current instructional techniques may inform instructor choice of teaching methods that impact the quality of education and improve the professional skills of students. © The International Society for Prosthetics and Orthotics 2014.