WorldWideScience

Sample records for provisional fixed partial

  1. A provisional fixed partial denture for an implant prosthesis.

    Science.gov (United States)

    Hansen, Paul A; Kim, Eunghwan

    2010-01-01

    This article presents a technique for fabricating an esthetic provisional restoration on multiple implants. Fabricating a provisional restoration allows the dentist to make a replica of the desired restoration. The incisal edge can be placed for esthetics and function in the new provisional restoration, allowing patients to evaluate comfort and test their ability to speak with the contour of the provisional restoration. Patients can evaluate both the ease of cleaning the restoration and how tissue esthetics can be duplicated to their satisfaction. By adding acrylic resin to or removing it from the provisional, the dentist can easily change the restoration until the patient is satisfied with the esthetic and functional result. This technique will allow the dentist to fabricate the provisional prosthesis quickly, while the patient is in the chair.

  2. In vitro evaluation of the flexural properties of All-on-Four provisional fixed denture base resin partially reinforced with fibers.

    Science.gov (United States)

    Li, Bei Bei; Xu, Jia Bin; Cui, Hong Yan; Lin, Ye; Di, Ping

    2016-01-01

    The aim of this study was to assess the effects of partial carbon or glass fiber reinforcement on the flexural properties of All-on-Four provisional fixed denture base resin. The carbon or glass fibers were woven (3% by weight) together in three strands and twisted and tightened between the two abutments in a figure-of-"8" pattern. Four types of specimens were fabricated for the three-point loading test. The interface between the denture base resin and fibers was examined using scanning electron microscopy (SEM). Reinforcement with carbon or glass fibers between two abutments significantly increased the flexural strength and flexural modulus. SEM revealed relatively continuous contact between the fibers and acrylic resin. The addition of carbon or glass fibers between two abutments placed on All-on-Four provisional fixed denture base resin may be clinically effective in preventing All-on-Four denture fracture and can provide several advantages for clinical use.

  3. The Conometric Concept: Coupling Connection for Immediately Loaded Titanium-Reinforced Provisional Fixed Partial Dentures-A Case Series.

    Science.gov (United States)

    Degidi, Marco; Nardi, Diego; Piattelli, Adriano

    2016-01-01

    The aim of this prospective study was to demonstrate the feasibility of the conic coupling connection as a novel approach for the retention of immediately loaded, titanium-reinforced, temporary fixed partial restorations. The patients received a fixed, immediate partial restoration, attached using the conic coupling connection to two implants placed in a fresh extraction socket. Changes in marginal peri-implant bone level or probing depth measurements, biologic or technical complications, and any other adverse event were recorded at yearly follow-ups up to 3 years after implantation. A total of 78 implants placed in 39 patients reached the 3-year follow-up. A trend of bone overgrowth over the implant platform (mean: 0.2 mm) and a complete fill of the vertical gap between the implant platform level and the first point of contact of the bone with the implant surface was seen after the 6-month follow-up. No disconnection of any prosthesis was noted during 3 years of full occlusal function. The results of this study suggest that titanium-reinforced, temporary partial restorations with conic coupling retention supported by immediate implants provide a successful, cost-effective treatment modality.

  4. The fixed/detachable implant provisional prosthesis.

    Science.gov (United States)

    Cibirka, R M; Linebaugh, M L

    1997-06-01

    Interim modification and management of a complete denture following surgical uncovering of dental implants can be time-intensive and may fail to provide adequate patient benefit until the definitive prosthesis can be completed. Inadequate interim management can result in functional and tissue difficulties. Modification of the conventional complete denture to a fixed/detachable provisional prosthesis in a one-stage procedure provides the patient an opportunity to experience a fixed prosthesis. The incorporation of fixed, provisional cylinders to the existing denture base using autopolymerizing acrylic resin with a closed-mouth technique is described. The peripheral regions are reduced and the distal extension shortened to resemble a fixed/detachable prosthesis. This conversion technique can provide patient satisfaction and comfort until delivery of the definitive prosthesis. Esthetic concerns, home care problems, or patient difficulties with the provisional prosthesis can be rectified in the final prosthesis.

  5. Immediate occluding definitive partial fixed prosthesis versus non-occluding provisional restorations - 4-month post-loading results from a pragmatic multicenter randomised controlled trial.

    Science.gov (United States)

    Heinemann, Friedhelm; Grufferty, Brendan; Papavasiliou, George; Dominiak, Marzena; García, Jaime Jiménez; Trullenque-Eriksson, Anna; Esposito, Marco

    2016-01-01

    To compare the clinical outcome of dental implants restored with definitive occluding partial fixed prostheses within 1 week, after implant placement with immediate non-occluding provisional restorations, which were to be replaced by definitive prostheses after 4 months. Fifty partially edentulous patients treated with one to three dental implants, at least 8.5 mm long and 4.0 mm wide inserted with a torque of at least 35 Ncm, were randomised in two groups of 25 patients each, to be immediately loaded with partial fixed prostheses. Patients of one group received one definitive screw-retained metal-ceramic prosthesis in occlusion within 1 week after placement. Patients of the other group received one non-occluding provisional acrylic reinforced prosthesis within 24 h after implant placement. Provisional prostheses were replaced after 4 months by definitive ones. The follow-up for all patients was 4-months post-loading. Outcome measures were prosthesis and implant failures, any complications, peri-implant marginal bone level changes, aesthetic evaluation by a clinician, patient satisfaction, chair time and number of visits at the dental office from implant placement to delivery of definitive restorations. No patient dropped out. Two immediately occlusally loaded implants with their related definitive prostheses (8%) failed early (difference in proportions = 0.08; 95% CI: -0.03 to 0.19; P = 0.490). Four complications occurred in the occlusal group versus one in the non-occlusal group; (difference in proportions = 0.12; 95% CI: -0.04 to 0.28; P = 0.349). Four months after loading, patients subjected to non-occlusal loading lost an average of 0.72 mm of peri-implant bone versus 0.99 mm of patients restored with occluding definitive partial fixed prostheses. There were no statistically significant differences for marginal bone level changes between the two groups (mean difference = -0.27 mm; 95% CI: -0.84 to 0.30; P = 0.349). The differences for aesthetic scores showed

  6. The Effect of Different Fiber Concentrations on the Surface Roughness of Provisional Crown and Fixed Partial Denture Resin

    OpenAIRE

    Zortuk, Mustafa; K?l?c, Kerem; Uzun, Gulay; Ozturk, Ahmet; Kesim, Bulent

    2008-01-01

    Objectives The aim of this study was to investigate surface roughness in provisional crown acrylics, after polishing, reinforced with different concentrations of glass fibers. Methods A total of 48 disk-shaped specimens were prepared using autopolymerizing acrylic resin. These specimens were divided into four groups according to the level of glass fiber added: Group A (no fiber), Group B (0.5%), Group C (1%) and Group D (2%). After polishing the specimens, an average surface roughness (Ra) va...

  7. Provisional implants for immediate restoration of partially edentulous jaws: a clinical study.

    Science.gov (United States)

    Krennmair, Gerald; Krainhöfner, Martin; Weinländer, Michael; Piehslinger, Eva

    2008-01-01

    The aim of this study was to evaluate the use of provisional implants, which can provide patients with provisional fixed partial dentures during the healing time of augmentation procedures and/or during the osseointegration period of definitive implants until delivery of the definitive prosthesis. Thirty-one patients were consecutively included in the study. Eighteen patients (group A, primary simultaneous group) were initially treated simultaneously with provisional and definitive implants and provided with 18 interim fixed partial dentures. Thirteen patients (group B) received provisional implants in a staggered procedure. In the first stage of group B patients (augmentation phase), provisional implants were placed to bridge the augmentation phase and for anchoring 13 interim fixed partial dentures. In the second stage (secondary simultaneous group), patients of group B received provisional implants to bridge the osseointegration phase for simultaneously placed definitive implants by further use of 13 interim fixed partial dentures. All patients were followed from provisional implant and definitive implant placement to delivery of the definitive prosthesis. Loss of provisional implants and interim fixed partial dentures was noted, and stability of provisional implants was evaluated using the Periotest device. The procedures of immediate rehabilitation with fixed partial dentures using provisional implants were subjectively rated by patients with regard to satisfaction, treatment period, and acceptance. In 31 patients, 44 provisional fixed partial dentures were supported by 98 provisional implants. No provisional implant loss in group A or group B-second stage was observed. Only 3 (3%) provisional implants were lost in group B-first stage during the augmentation phase. Incidence (90.8% versus 9.2%) and stability (Periotest values: 8.6 +/- 3.9 versus 4.8 +/- 2.7) of provisional implants differed significantly between maxilla and mandible (P fixed partial dentures

  8. Bacterial adhesion of porphyromonas gingivalis on provisional fixed prosthetic materials

    Directory of Open Access Journals (Sweden)

    Mustafa Zortuk

    2010-01-01

    Conclusion : The quantity of bacterial adhesion and surface roughness differed among the assessed provisional fixed prosthodontic materials. The light-polymerized provisional material Revotek LC had rougher surface and more bacterial adhesion compared with the others.

  9. Using a fixed provisional prosthesis during post-extraction healing and implant placement.

    Science.gov (United States)

    McArdle, Barry F

    2006-03-01

    Most dental patients insist on the use of provisional prostheses throughout healing and osseointegration when replacing extracted teeth with implants in esthetically sensitive areas. Removable appliances of some kind are normally used for this purpose, but patients often consider them to be too cumbersome. This can lead to decreased case acceptance and compliance with the use of the provisional restoration, which can compromise the final result of treatment. Custom fixed solutions to this problem exist, but they tend to be more complicated, less practical, and more expensive than other options now available. The Monodont bridge, a new system of prefabricated components for the creation of provisional fixed partial dentures, can be more esthetic, more retentive, more functional, more cost-effective, and more universally applicable than any other available techniques. This can raise patient tolerance of provisional prostheses and thus increase case acceptance, while fostering a more predictable esthetic result with regard to soft tissue contours and emergence profile.

  10. Fixed and removable provisional options for patients undergoing implant treatment.

    Science.gov (United States)

    Cho, Sang-Choon; Shetty, Saphal; Froum, Stuart; Elian, Nicolas; Tarnow, Dennis

    2007-11-01

    The provisional phase of treatment can be the most challenging aspect of implant dentistry. The techniques available today include removable, tooth-supported, and implant-retained provisional restorations. The selection of the type of provisional prosthesis should be based on esthetic demands, functional requirements, duration, and ease of fabrication. This article includes a review of 118 articles from peer-reviewed journals published in English from January 1986 to February 2007. This review was performed using MEDLINE. The indications, advantages, and disadvantages of the various provisional restorations are discussed.

  11. Indirect implant-supported fixed provisional restoration in the esthetic zone: fabrication technique and treatment workflow.

    Science.gov (United States)

    Shor, Alexander; Schuler, Ralf; Goto, Yoshihiro

    2008-01-01

    Treatment objectives of an implant-supported fixed provisional restoration include shaping/preservation of the gingival soft tissue contour, functional and esthetic substitution of the missing dentition during postsurgical healing, and definitive prosthesis fabrication stages. Fixed provisional restoration can also serve as an esthetic and functional blueprint in the fabrication of the definitive restoration. Despite its common use and important indications, limited information is available on the various aspects of the provisional fabrication and treatment. This article presents a production technique and treatment workflow of a laboratory-fabricated, screw-retained fixed provisional restoration. Provisional restoration is fabricated using layering technique and internal stain characterization. The soft tissue profile of the working cast is modified according to the coronal contour of the diagnostic wax-up. Upon delivery, the provisional contour is reevaluated and modified as necessary. The developed emergence profile of the provisional restoration is transferred to the master cast via customized impression copings. Laboratory-fabricated implant-supported provisional restorations allow the esthetic and functional substitution of the missing dentition and the shaping of the soft tissue profile, and can act as a blueprint in the fabrication of definitive restorations.

  12. Mechanical properties of four methylmethacrylate-based resins for provisional fixed restorations.

    Science.gov (United States)

    Hernandez, E P; Oshida, Y; Platt, J A; Andres, C J; Barco, M T; Brown, D T

    2004-01-01

    The use of a provisional restoration is an important phase in the treatment of the dental prosthetic patient. A good provisional restoration should satisfy the following requirements: pulpal protection, positional stability, ease in cleaning, accurate margins, wear resistance, dimensional stability, and serve as a diagnostic aid in treatment assessment and esthetics. There is a tendency for discoloration, occlusal wear, and fracture that eventually leads to unnecessary repair. Heat-processed and reinforced methacrylate-based resins have been used to improve the mechanical and physical properties of provisional restorations. Among various improvements, the interpenetrating network crosslinked PMMA (IPN) has been shown to have superior mechanical properties if manufactured through a dough compression molding process at 130 degrees C. However, there have been no published data that relate with the use of this material for fixed provisional restorations. The objective of this study was to compare four methyl methacrylate-based resins for provisional crowns and bridges with varying processing cycles, including JET [self-cure], ACRALON [heat-cured], titanium dioxide filled PMMA [heat-cured], and IPN [heat-cured denture tooth resin]. Properties studied included transverse strength, toughness, rigidity, and hardness. From the results of this study the following conclusions can be made: the IPN group may have had a lower degree of conversion as demonstrated by decreased strength, toughness, and hardness data as compared with Acralon. Increasing the polymerization cycle of unmodified Acralon resin causes a significant increase in strength.

  13. Vector-controlled alveolar distraction osteogenesis using an implant-fixed provisional prosthesis: a case report.

    Science.gov (United States)

    Kawashima, Wataru; Takayama, Kenichi; Fujii, Ryosuke; Matsubara, Yuuri; Kirita, Tadaaki

    2013-02-01

    This is a case report of anterosuperior alveolar distraction using an implant-fixed provisional prosthesis. Osteotomy and placement of a distraction device were performed in a healthy 69-year-old woman. To avoid lingual inclination during the distraction period, the device's rod was buried in the labial side of a provisional prosthesis supported by posterior implants. The mandibular bone was obliquely distracted by 0.3 mm every 2 days. Implant insertion was performed, and a good prognosis was anticipated. Inclination is thought to be caused by soft tissue on the lingual side. Many reports propose methods to avoid inclination, but these methods require established support from the teeth and cannot be adapted for an edentulous case. The method reported here is useful for distraction osteogenesis because it can be adapted for edentulous cases.

  14. A technique for indirect fabrication of a complete-arch, implant-supported, fixed provisional restoration from a radiographic template.

    Science.gov (United States)

    Spyropoulou, Panagiota-Eirini; Razzoog, Michael; Sierraalta, Marianella

    2010-09-01

    This article describes an alternative technique for the fabrication of a complete-arch, implant-supported, cement-retained, fixed provisional restoration. The definitive cast is fabricated from the surgical guide and the provisional restoration is fabricated indirectly from the radiographic guide. This technique is an easy and time-saving procedure to fabricate an interim prosthesis for immediate or delayed loading of implants. Copyright © 2010 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  15. Innovative approach to computer-guided surgery and fixed provisionalization assisted by screw-retained transitional implants.

    Science.gov (United States)

    Gallucci, German O; Finelle, Gary; Papadimitriou, Dimitrios E V; Lee, Sang J

    2015-01-01

    The objectives of this case series are to describe a novel clinical approach to treat completely edentulous patients and determine its viability. Computer-guided implant planning was used to create a screw-retained surgical template (ST) supported by transitional implants and a fixed screw-retained provisional prosthesis supported by the transitional implants at the time of definitive implant placement. Five patients with at least one edentulous arch were treated. After the diagnostic tooth setup was performed, a duplicate with radiopaque acrylic resin was fabricated to serve as a surgical template (ST) for the placement of screw-form transitional implants and a radiographic guide (RG). Four transitional implants were strategically placed through the guide where they would not interfere with the future definitive implants. The transitional implants were used to support the RG during computed tomographic scanning. Subsequently, the RG was converted into a second ST based on three-dimensional virtual planning. Eight implants were placed by the computer-guided system, and an immediate prefabricated fixed provisional was connected to the transitional implants. All the implants included in the study achieved primary stability and osseointegrated successfully. For 4 months, the transitional implants served successfully as abutments for the provisional prosthesis. This innovative clinical approach overcomes the limitations of a mucosa/bone-supported ST by offering fixed, reproducible support for the RG and ST by means of transitional implants. The delivery of a prefabricated screw-retained provisional on transitional implants allows for passive healing and minimum chairside adjustments.

  16. Fabrication of a screw-retained fixed provisional prosthesis supported by dental implants.

    Science.gov (United States)

    Kökat, Ali Murat; Akça, Kivanç

    2004-03-01

    Screw-retained provisional implant-supported prostheses may have advantages over cement-retained prostheses in certain situations. This article describes a technique for fabrication of screw-retained provisional acrylic resin implant-supported prostheses from the modified metal components provided with the implant.

  17. Prosthetic reconstruction using gingiva-colored ceramic agent in fixed partial restoration in a 24-year old patient

    Directory of Open Access Journals (Sweden)

    Sadaqah NR

    2012-11-01

    Full Text Available Nasrin R Sadaqah,1 Jawad Ali Abu Tair21Department of Prosthodontics, 2Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Arab American University, Jenin, Palestinian TerritoryAbstract: Achieving an optimal esthetic result when replacing missing anterior teeth with a fixed partial denture can be a challenge. This is especially true when interdisciplinary treatment is needed and the patient refuses this for personal or financial reasons. Here we report a clinical case where a fixed partial denture was used to change the incisor relationship and to restore the normal tooth and gingival tissue shape, morphology, and relationship by including artificial gingiva within the fixed partial denture when the patient refused lengthy and costly multispecialty treatment options.Keywords: gingival porcelain, fixed partial denture, diagnostic waxup, provisional restoration

  18. Partial rectangular metric spaces and fixed point theorems.

    Science.gov (United States)

    Shukla, Satish

    2014-01-01

    The purpose of this paper is to introduce the concept of partial rectangular metric spaces as a generalization of rectangular metric and partial metric spaces. Some properties of partial rectangular metric spaces and some fixed point results for quasitype contraction in partial rectangular metric spaces are proved. Some examples are given to illustrate the observed results.

  19. Immediate loading of definitive implants in the edentulous mandible using a fixed provisional prosthesis: The denture conversion technique.

    Science.gov (United States)

    Misch, Craig M

    2004-09-01

    This article presents a clinical technique for immediate implant loading in the completely edentulous mandible. The protocol recommends the placement of 4 to 5 root-form implants in the anterior mandible between the mental foramina. Upon insertion the implants must have favorable primary stability. Abutments are added to the implants and the patient's lower denture is converted into an immediate load provisional fixed prosthesis. The denture conversion technique has been shown to provide predictable results for immediate implant loading in the edentulous mandible. The final prosthesis is fabricated upon integration of the implants in 3 months. The denture conversion technique offers several advantages because it may be used with most commercially available implant systems and it incorporates conventional implant components. Guidelines for patient selection, presurgical preparation, implant surgery, prosthesis fabrication, and postoperative care are reviewed.

  20. A Treatment Protocol for Restoring Occlusal Vertical Dimension Using an Overlay Removable Partial Denture as an Alternative to Extensive Fixed Restorations: A Clinical Report

    OpenAIRE

    Patel, Mit B; Bencharit, Sompop

    2009-01-01

    Treatment options for patients with severe attrition resulting in reduced occlusal vertical dimension are often limited to fixed prosthesis to reestablish proper occlusal vertical dimension and functional occlusion. In some cases such as when there are limited finances, minimal esthetic concerns, and medical considerations fixed prosthesis may not be the ideal treatment option. Overlay removable partial dentures (ORPDs) can be used as a provisional or interim prosthesis as well as permanent p...

  1. Weak partial metric spaces and some fixed point results

    Directory of Open Access Journals (Sweden)

    Ishak Altun

    2012-10-01

    Full Text Available The concept of partial metric p on a nonempty set X was introduced by Matthews. One of the most interesting properties of a partial metric is that p(x, x may not be zero for x e X. Also, each partial metric p on a nonempty set X generates a T0 topology on X. By omitting the small self-distance axiom of partial metric, Heckmann defined the weak partial metric space. In the present paper, we give some fixed point results on weak partial metric spaces.

  2. Conversion of a complete denture to a provisional implant-supported, screw-retained fixed prosthesis for immediate loading of a completely edentulous arch.

    Science.gov (United States)

    Kammeyer, Greg; Proussaefs, Periklis; Lozada, Jaime

    2002-05-01

    This article describes the fabrication of a provisional implant-supported, screw-retained restoration for immediate loading of a completely edentulous arch. The technique can be applied to patients with partially edentulous arches as well. Until immediate loading of dental implants becomes a well-documented treatment modality, the described method should not be applied on a routine basis or without careful evaluation.

  3. Esthetic Outcome of Implant Supported Crowns With and Without Peri-Implant Conditioning Using Provisional Fixed Prosthesis: A Randomized Controlled Clinical Trial.

    Science.gov (United States)

    Furze, David; Byrne, Ashley; Alam, Sonia; Wittneben, Julia-Gabriela

    2016-12-01

    Achieving an optimal esthetic result using dental implants is challenging. Fixed implant-supported provisional crowns are often used to customize the emergence profile and to individualize the surrounding peri-implant soft tissue. The objective of this study is to evaluate whether the use of a provisional implant-supported crown leads to an esthetic benefit on implants that are placed in the esthetic zone. The null hypothesis is that there is no-difference between the two study groups. Twenty single implants (Bone Level, Straumann AG, Basel, Switzerland) were inserted in consecutive patients. After reopening, a randomization process assigned them to either cohort group 1: a provisional phase with soft tissue conditioning using the "dynamic compression technique" or cohort group 2: without a provisional. Implants were finally restored with an all-ceramic crown. Follow-up examinations were performed at 3 and 12 months including implant success and survival, clinical, and radiographic parameters. After 1 year all implants successfully integrated, mean values of combined modPES and WES were 16.7 for group 1 and 10.5 for Group 2. This was statistically significant. Mean bone loss after 1 year was -0.09 and -0.08 for groups 1 and 2, respectively, without being statistically significant. A provisional phase with soft tissue conditioning does improve the final esthetic result. © 2016 Wiley Periodicals, Inc.

  4. A Fixed Point Theorem for Multifunctions in Partial Metric spaces

    Directory of Open Access Journals (Sweden)

    Priscilla S. Macansantos

    2013-08-01

    Full Text Available Fixed Point theorems on partial metric spaces have been the subject of recent work, with the interest generated in partial metric spaces (as a suitable structure for studies in theoretical computer science. Several approaches to fixed point theory for point-valued functions on complete metric spaces have been generalized to partial metric spaces (see, for instance, Alghamdi [1]. On the other hand, it appears that substantial work may still be done to generalize the theory (in the partial metric space context to set-valued functions. Recently, Damjanovic et al [3] looked into pairs of multi-valued and single-valued maps in complete metric spaces, and used coincidence and common fixed points, to establish a theorem on fixed points for pairs of multivalued functions. In this paper we take off from Damjanovic and proceed to establish the same result in the setting of partial metric spaces. As a consequence of our generalization, we are able to include as special cases the theorem of Aydi et al [2] and our [9] generalization of [4]. Further, Reich's result is also generalized to multivalued functions in partial metric spaces. Special cases include the partial metric space version of Kannan's theorem, as well as that due to Hardy and Rogers.

  5. Fixed partial dentures with an all-ceramic system: a case report.

    Science.gov (United States)

    Zawta, C

    2001-05-01

    The success of a dental prosthesis is judged according to function, comfort, phonetics, and esthetics. The purpose of a treatment is to come as close as possible to replicating the natural state. For anterior fixed partial dentures, the all-ceramic system IPS Empress 2 offers light transmission and reflection comparable to that of natural teeth, provided that the pink esthetics are optimized in the preprosthetic treatment phase. In this case report, a laboratory-made provisional was placed after extraction of an anterior tooth. Six months later, preprosthetic periodontal surgery was carried out to enhance gingival harmony. The design of the post and core, preparation, and cementation are important parameters for the success of all-ceramic restorations.

  6. Reinforcement of acrylic resins for provisional fixed restorations. Part III: effects of addition of titania and zirconia mixtures on some mechanical and physical properties.

    Science.gov (United States)

    Panyayong, W; Oshida, Y; Andres, C J; Barco, T M; Brown, D T; Hovijitra, S

    2002-01-01

    Acrylic resins have been used in many different applications in dentistry, especially in the fabrication of provisional fixed partial dentures. Ideally, a provisional crown and bridge material should be easy to handle and should protect teeth against physical, chemical, and thermal injuries. Some of the problems associated with this use are related to the material's poor mechanical properties. It has been demonstrated that acrylic resin can be strengthened through the addition of structural component of different size distributed in the acrylic matrix, thus forming a composite structure. The purpose of this study was to investigate the addition effects of mixtures of titania (titanium dioxide, TiO(2)) powder and zirconia (zirconium dioxide, ZrO(2)) powder being incorporated with pre-polymerized beads mixed in monomer liquid, on some mechanical and physical properties of PMMA resin. The pre-polymerized powder poly(methyl methacrylate) resin was admixed with titania and zirconia powder. A mixing ratio was controlled by volume % of 0, 1.0, 2.0, and 3.0 (samples with 0 v/o served as control groups). For using mixture of titania and zirconia, total amount of the mixture was controlled by volume % of 1.0, 2.0, and 3.0, in which titania and zirconia were mixed at the ratio 1 :1, 1 :2 and 2 :1. Prior to mechanical tests, all rectangular-shaped samples (25 mm x 2 mm x 5 mm) were stored in 37 degrees C distilled water for 7 days after polishing all six sides of samples. Samples were then subjected to the three-point bending flexion test to evaluate the bending strength as well as the modulus of elasticity. Weight gain and exothermic reaction survey were investigated as well. All data were collected and analyzed with one-way analysis of variance (ANOVA) and Sidak method (p=0.05). It was found that the addition of particles generally decreased the water absorbed by the composite system. Only 1 percent by volume concentration of 1 :1 ratio and 2 percent by volume concentration

  7. Fixed partial dentures investigated by optical coherent tomography

    Science.gov (United States)

    Sinescu, Cosmin; Negrutiu, Meda; Todea, Carmen; Hughes, Mike; Tudorache, Florin; Podoleanu, Adrian G.

    2008-02-01

    Fixed partial prostheses as integral ceramics, integral polymers, metal ceramics or metal polymers bridges, are mainly used in the frontal part of the dental arch (especially the integral bridges). They have to satisfy high stress requirements as well as esthetic. The masticatory stress may induce fractures of the bridges. These may be triggered by initial materials defects or by alterations of the technological process. The fractures of these bridges lead to functional, esthetic and phonetic disturbances which finally render the prosthetic treatment inefficient. The purpose of this study is to evaluate the capability of en-face optical coherence tomography (OCT) in detection and analysis of possible fractures in several integral fixed partial dentures. The materials used were represented by several fixed partial prostheses, integral ceramics, integral polymers, metal ceramics and metal polymers bridges. In order to discover the defects, scanning was performed from incisal, vestibular, oral and cervical directions material defects such as fractures and pores were investigated using OCT. In conclusion, en-face OCT has proven as a valuable non invasive method to investigate fixed partial prostheses before their insertion in the oral cavity.

  8. Tripled coincidence and fixed point results in partial metric spaces

    Directory of Open Access Journals (Sweden)

    Hassen Aydi

    2012-10-01

    Full Text Available In this paper, we introduce the concept of W-compatiblity of mappings F : X × X × X ! X and g : X ! X and based on this notion, we obtain tripled coincidence and common tripled fixed point results in the setting of partial metric spaces. The presented results generalize and extend several well known comparable results in the existing literature. We also provide an example to support our results.

  9. Three-Year Outcome of Fixed Partial Rehabilitations Supported by Implants Inserted with Flap or Flapless Surgical Techniques.

    Science.gov (United States)

    Maló, Paulo; de Araújo Nobre, Miguel; Lopes, Armando

    2016-07-01

    The aim of this prospective clinical study was to evaluate the 3-year outcome of fixed partial prostheses supported by implants with immediate provisionalization without occlusal contacts inserted in predominantly soft bone with flap and flapless protocols. Forty-one patients partially rehabilitated with 72 NobelSpeedy implants (51 maxillary; 21 mandibular) were consecutively included and treated with a flapless surgical protocol (n = 20 patients; 32 implants) and flapped surgical protocol (n = 21 patients; 40 implants). Primary outcome measure was implant survival; secondary outcome measures were marginal bone resorption (comparing the bone levels at 1 and 3 years with baseline) and the incidence of biological, mechanical, and esthetic complications. Survival was computed through life tables; descriptive statistics were applied to the remaining variables of interest. Eight patients with eight implants dropped out of the study. One implant failed in one patient (flapless group) giving an overall cumulative survival rate (CSR) of 98.6%. No failures were noted with the flapped protocol (CSR 100%), while for the implants placed with the flapless surgical technique, a 96.9% CSR was registered. The overall average marginal bone resorption at 3 years was 1.37 mm (SD = 0.94 mm), with 1.14 mm (SD = 0.49 mm) and 1.60 mm (SD = 1.22 mm) for the flap and flapless groups, respectively. Mechanical complications occurred in nine patients (n = 5 patients in the flapless group; n = 4 patients in the flap group). Implant infection was registered in three implants and three patients (flapless group), who exhibited inadequate oral hygiene levels. Partial edentulism rehabilitation through immediate provisionalization fixed prosthesis supported by dental implants inserted through flap or flapless surgical techniques in areas of predominantly soft bone was viable at 3 years of follow-up. The limitations and risks of the "free-hand" method in flapless surgery should be considered when

  10. Marginal Integrity of CAD/CAM Fixed Partial Dentures

    OpenAIRE

    Rosentritt, Martin; Behr, Michael; Kolbeck, Carola; Handel, Gerhard

    2007-01-01

    Objectives Computer-aided design (CAD) and manufacturing (CAM) allows the milling of high strength zirconia fixed partial dentures (FPD), however bonding to an inert ZrO2 ceramic surface may effect the marginal integrity of the FPDs. The aim of this investigation was to evaluate the marginal adaptation of zirconia FPDs at the interfaces between zirconia, cement, and tooth. Methods 32 3-unit FPDs were fabricated of the CAD/CAM Y-TZP zirconia (Lava, 3M Espe, Germany) according to the manufactur...

  11. Immediate occlusal loading in edentulous jaws, CT-guided surgery and fixed provisional prosthesis: a maxillary arch clinical report.

    Science.gov (United States)

    Drago, Carl; del Castillo, Robert; Peterson, Thomas

    2011-04-01

    Immediate occlusal loading (IOL) in edentulous jaws has been reported in numerous publications with implant cumulative survival rates consistent with conventional, unloaded healing protocols. Computed Tomography (CT)-guided surgery has more recently been developed and accepted as an additional treatment modality for maxillary and mandibular implant placement, with or without IOL. Reports as to the accuracy of planned versus actual implant placement in CT-guided surgeries have indicated that CT-guided surgery is not 100% accurate; standard deviations have been reported with values between 1 and 2 mm in terms of actual versus planned placement. The purpose of this article is to review the clinical parameters associated with IOL, and CT-guided surgery in edentulous jaws; and to present a clinical case illustrating the clinical and laboratory phases of treatment. The illustrated treatment was accomplished with an IOL protocol and includes fabrication and placement of a laboratory-processed provisional maxillary prosthesis. This particular protocol had slightly increased costs relative to conventional implant placement; however, the clinicians and patient benefited from improved accuracy of the provisional prostheses and decreased chairtime for the clinical procedures. The benefits and limitations of this treatment protocol are also discussed. © 2010 by The American College of Prosthodontists.

  12. Fiber-reinforced composites in fixed partial dentures

    Science.gov (United States)

    Vallittu, Pekka

    2006-01-01

    Fiber-reinforced composite resin (FRC) prostheses offer the advantages of good aesthetics, minimal invasive treatment, and an ability to bond to the abutment teeth, thereby compensating for less-than-optimal abutment tooth retention and resistance form. These prostheses are composed of two types of composite materials: fiber composites to build the framework and hybrid or microfill particulate composites to create the external veneer surface. This review concentrates on the use of fiber reinforcement in the fabrication of laboratory or chairsidemade composite-fixed partial dentures of conventional preparation. Other applications of FRC in dentistry are briefly mentioned. The possibilities fiber reinforcement technology offers must be emphasized to the dental community. Rather than limiting discussion to whether FRC prostheses will replace metal-ceramic or full-ceramic prostheses, attention should be focused on the additional treatment options brought by the use of fibers. However, more clinical experience is needed. PMID:21526023

  13. Fiber-reinforced composites in fixed partial dentures

    Directory of Open Access Journals (Sweden)

    Vallittu P

    2006-08-01

    Full Text Available Fiber-reinforced composite resin (FRC prostheses offer the advantages of good esthetics, minimal invasive treatment, and an ability to bond to the abutment teeth, thereby compensating for less-than-optimal abutment tooth retention and resistance form. These prostheses are composed of two types of composite materials: fiber composites to build the framework and hybrid or microfill particulate composites to create the external veneer surface. This review concentrates on the use of fiber reinforcement in the fabrication of laboratory or chairside-made composite-fixed partial dentures of conventional preparation. Other applications of FRC in dentistry are briefly mentioned. The possibilities fiber reinforcement technology offers must be emphasized to the dental community. Rather than limiting discussion to whether FRC prostheses will replace metal-ceramic or full-ceramic prostheses, attention should be focused on the additional treatment options brought by the use of fibers. However, more clinical experience is needed.

  14. Versatility of PEEK as a fixed partial denture framework

    Directory of Open Access Journals (Sweden)

    Nikita Sinha

    2017-01-01

    Full Text Available Materials used for fixed partial denture (FPD frameworks have had properties of excellent strength, durability, and biocompatibility. Some of the materials which have been used till date include alloys, ceramics, and high-performance polymers such as zirconia, Ni–Cr, lithium disilicate, and so on. All these, though excellent, have their advantages and disadvantages. Hence, the search has always been on for a better material. One such material, which has made its foray into dentistry in the recent times, is polyetheretherketone (PEEK. It is a semicrystalline thermoplastic material. PEEK has an excellent chemical resistance and mechanical properties that are retained at high temperatures. The versatility of PEEK as a dental material for FPD framework was evaluated in this case report.

  15. Strength of zirconia fixed partial dentures: review of the literature.

    Science.gov (United States)

    Gargari, M; Gloria, F; Cappello, A; Ottria, L

    2010-10-01

    The aim of this study is a systematic review of the literature on the strength and long-term behavior of zirconia FPDs. The literature search was performed using as the primary source the Medline database. Were also imposed a set of inclusion and exclusion criteria in order to narrow the search to differentiate the two distinct parts in which it was structured the review. In addition, MeSH terms were applied to further refine the choice of articles more relevant to the review. In the part of the review concerning the long-term behavior of zirconia fixed partial dentures were considered useful only those studies with a minimum follow-up of one year. The search provided a total of 813 articles, but only 25 were considered for the review because they were the only ones who satisfied search criteria. In particular, 13 items relate to the mechanical strength of zirconia prostheses and 12 regarding the long term behavior of zirconia FPDs. The resistance values also exceed the 2000 N while the survival rate reaches to almost 94%. Based on this review, Zirconia FPDs can be considered reliable products in both the anterior and posterior fields with survival rates comparable to traditional metal-ceramic prostheses.

  16. Quadruple fixed point theorems for nonlinear contractions on partial metric spaces

    Directory of Open Access Journals (Sweden)

    Erdal Karapinar

    2014-04-01

    Full Text Available The notion of coupled fixed point was introduced by Guo and Laksmikantham [12]. Later Gnana Bhaskar and Lakshmikantham in [11] investigated the coupled fixed points in the setting of partially ordered set by defining the notion of mixed monotone property. Very recently, the concept of tripled fixed point was introduced by Berinde and Borcut [7]. Following this trend, Karapınar[19] defined the quadruple fixed point. In this manuscript, quadruple fixed point is discussed and some new fixed point theorems are obtained on partial metric spaces.

  17. Ten-year survival rate for cantilevered fixed partial dentures.

    Science.gov (United States)

    Anderson, James D

    2005-01-01

    PubMed (1966-April 2004) provided the primary data source along with the bibliographies from identified articles and reviews. A manual search of two relevant journals (Clinical Implant Dentistry and Related Research, Clinical Oral Implants Research, International Journal of Oral & Maxillofacial Implants, International Journal of Periodontics and Restorative Dentistry, International Journal of Prosthodontics, Journal of Clinical Periodontology, Journal of Periodontology and Journal of Prosthetic Dentistry published; published 2001-2003) provided a further source of data. Because there were no randomised controlled trials (RCT) that compared fixed partial dentures (FPD) with and without cantilever extensions, other studies were selected if they met the following criteria: were published in the English language; were prospective and retrospective cohort studies; had a mean follow-up of >5 years; included patients who were clinically examined at follow-up; and reported details on suprastructures and described at least one-third of reconstructions as FPD. Two independent reviewers screened articles for inclusion. Disagreements were resolved by discussion and agreement determined by kappa. Two reviewers extracted data on the survival and success of the reconstructions and on biological and technical complications. Failure and complication rates were calculated by dividing the number of events by the total exposure time. Three prospective and 10 retrospective cohort studies incorporating 700 patients and 816 FPD were included. The mean number of cantilever extensions ranged from 1.1 to 6.0. Meta-analyses gave an estimated survival, after 10 years, of 81.8% [95% confidence interval (CI), 78.2-84.9] and a proportion success of 63% (95% CI, 54.7-70.2). Considering biological complications using Poisson model analyses, the estimated rate of FPD lost because of caries after 10 years was 3.1% (95%CI, 1.0-8.8) and that for loss of vitality was 32.6% (95% CI, 13.9-64.9). The rate

  18. Retrospective analysis of 56 edentulous dental arches restored with 344 single-stage implants using an immediate loading fixed provisional protocol: statistical predictors of implant failure.

    Science.gov (United States)

    Kinsel, Richard P; Liss, Mindy

    2007-01-01

    The purpose of this retrospective study was to evaluate the effects of implant dimensions, surface treatment, location in the dental arch, numbers of supporting implant abutments, surgical technique, and generally recognized risk factors on the survival of a series of single-stage Straumann dental implants placed into edentulous arches using an immediate loading protocol. Each patient received between 4 and 18 implants in one or both dental arches. Periapical radiographs were obtained over a 2- to 10-year follow-up period to evaluate crestal bone loss following insertion of the definitive metal-ceramic fixed prostheses. Univariate tests for failure rates as a function of age ( or = 60 years), gender, smoking, bone grafting, dental arch, surface type, anterior versus posterior, number of implants per arch, and surgical technique were made using Fisher exact tests. The Cochran-Armitage test for trend was used to evaluate the presence of a linear trend in failure rates regarding implant length and implant diameter. Logistic regression modeling was used to determine which, if any, of the aforementioned factors would predict patient and implant failure. A significance criterion of P = .05 was utilized. Data were collected for 344 single-stage implants placed into 56 edentulous arches (39 maxillae and 17 mandibles) of 43 patients and immediately loaded with a 1-piece provisional fixed prosthesis. A total of 16 implants failed to successfully integrate, for a survival rate of 95.3%. Increased rates of failure were associated with reduced implant length, placement in the posterior region of the jaw, increased implant diameter, and surface treatment. Implant length emerged as the sole significant predictor of implant failure. In this retrospective analysis of 56 consecutively treated edentulous arches with multiple single-stage dental implants loaded immediately, reduced implant length was the sole significant predictor of failure.

  19. On Fixed Points of Generalized α-φ Contractive Type Mappings in Partial Metric Spaces

    Directory of Open Access Journals (Sweden)

    Priya Shahi

    2016-08-01

    Full Text Available Recently, Samet et al. (B. Samet, C. Vetro and P. Vetro, Fixed point theorem for $\\alpha$-$\\psi$ contractive type mappings, Nonlinear Anal. 75 (2012, 2154--2165 introduced a very interesting new category of contractive type mappings known as $\\alpha$-$\\psi$ contractive type mappings. The results obtained by Samet et al. generalize the existing fixed point results in the literature, in particular the Banach contraction principle. Further, Karapinar and Samet (E. Karapinar and B. Samet, Generalized $\\alpha$-$\\psi$-contractive type mappings and related fixed point theorems with applications, Abstract and Applied Analysis 2012 Article ID 793486, 17 pages doi:10.1155/2012/793486 generalized the $\\alpha$-$\\psi$ contractive type mappings and established some fixed point theorems for this generalized class of contractive mappings. In (G. S. Matthews, Partial metric topology, Ann. New York Acad. Sci. 728 (1994, 183--197, the author introduced and studied the concept of partial metric spaces, and obtained a Banach type fixed point theorem on complete partial metric spaces. In this paper, we establish the fixed point theorems for generalized $\\alpha$-$\\psi$ contractive mappings in the context of partial metric spaces. As consequences of our main results, we obtain fixed point theorems on partial metric spaces endowed with a partial order and that for cyclic contractive mappings. Our results extend and strengthen various known results. Some examples are also given to show that our generalization from metric spaces to partial metric spaces is real.

  20. A prospective evaluation of zirconia anterior partial fixed dental prostheses: Clinical results after seven years.

    Science.gov (United States)

    Solá-Ruíz, Maria Fernanda; Agustin-Panadero, Rubén; Fons-Font, Antonio; Labaig-Rueda, Carlos

    2015-06-01

    Because of the high mechanical strength of zirconium dioxide, the metal in fixed partial prostheses can now be replaced. However, the material is susceptible to aging or hydrothermal degradation and to chipping of the feldspathic veneer. The purpose of this prospective study was to evaluate the survival (without failure) and success (survival without any complication or failure) rate and clinical efficacy of anterior zirconia partial fixed dental prostheses. Twenty-seven anterior partial fixed dental prostheses of 3 to 6 units were fabricated. All participants were examined after 1 month and 6 months, then annually for 7 years. Three partial fixed dental prostheses failed and had to be removed: 2 because of secondary caries, which increased failure significantly (P=.001) and 1 because of severe chipping. Six partial fixed dental prostheses had complications: 2 debonded, 3 had chipping, and 1 had periapical pathology. All veneer porcelain fractures occurred in 6-unit fixed partial prostheses (P=.002). The clinical success rate was 88.8% after the 7-year follow-up. The clinical behavior of partial fixed dental prostheses with a zirconium dioxide core in the anterior region provides an adequate medium-term survival rate. The main cause of failure was secondary caries. The most frequent complication was chipping, which was directly related to the number of units of the prosthesis. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  1. The Hong Kong Bridge Protocol. Immediate loading of mandibular Brånemark fixtures using a fixed provisional prosthesis: preliminary results.

    Science.gov (United States)

    Chow, J; Hui, E; Liu, J; Li, D; Wat, P; Li, W; Yau, Y K; Law, H

    2001-01-01

    The Brånemark System Classic is well documented for its successful and predictable results in dental implant rehabilitation. However, the classic two-stage protocol is associated with problems, such as long treatment time and high treatment cost. To overcome these problems, new developments, including early functional loading protocol and Brånemark System Novum, have been introduced by various groups of researchers. In Hong Kong, a protocol has been developed to immediately load the Brånemark System fixtures with a fixed provisional prosthesis. The goal of this prospective study was to present the Hong Kong Bridge protocol and report the short-term evaluation of this protocol in a group of patients who had undergone dental implant treatment for their edentulous mandibles. Twenty-seven consecutive patients being treated at the Hong Kong Osseointegration Implant Centre between June 1998 and December 2000 were included in this study. A total of 123 Brånemark System fixtures were installed and regularly followed up for 3 to 30 months. The prosthesis stability and the marginal bone level were regularly evaluated clinically and radiographically, respectively, after the implant surgery. Fifteen of the 27 patients had been followed up for 1 year or longer. Two patients with eight fixtures were withdrawn from the study. Two of the 115 remaining fixtures failed, resulting in an overall implant survival rate of 98.3%. The mean marginal bone change was reported on 49 fixtures that had passed the 1-year review. The mean marginal bone loss was 0.60 mm (p < .05) after 1 year of functional loading. To load the mandibular Brånemark System fixtures immediately according to the Hong Kong Bridge protocol was a predictable and simple method with good results during this preliminary study period.

  2. Fiber-reinforced composites in fixed partial dentures | Garoushi ...

    African Journals Online (AJOL)

    These prostheses are composed of two types of composite materials: fiber composites to build the framework and hybrid or microfill particulate composites to create the external veneer surface. This review concentrates on the use of fiber reinforcement in the fabrication of laboratory or chairside-made compositefixed partial ...

  3. On Common Coupled Fixed Point Theorems for Comparable Mappings in Ordered Partially Metric Spaces

    OpenAIRE

    Ali Mutlu; Nermin Yolcu; Berrin Mutlu; Necdet Bildik

    2013-01-01

    Common coupled fixed point theorems are examined in this paper for comparable mappings ensuring nonlinear contraction in ordered partial metric spaces. Given theorems enlarge and universalize some conclusions of Gnana Bhaskar and Lakshmikantham (2006).

  4. Development of a device to study fatigue life of fixed partial dentures

    Science.gov (United States)

    Gutierrez, S. C.; Meseguer, M. D.; Estal, R.; Folguera, F.; Vidal, V.

    2012-04-01

    Fixed partial dentures can be fabricated by means of different materials and with different manufacturing processes. In order to establish possible differences among them, their behaviour, as fatigue life or cement shear bond strength, have to be evaluated. This article presents a modular, economic and robust device to evaluate fixed partial dentures and dental crowns. A base to support the fixed partial dentures and a device to simulate masticatory loads have been developed. The device has got a simple design. It is based on a pneumatic piston, with a pressure regulator to control masticatory loads. On a first stage, only vertical forces have been taking into account. However, the device will allow simulating tangential masticatory loads on the other axis, studying the behaviour of the fixed partial dentures submerged in a solution similar to saliva, changing masticatory load application, etc. with little modifications.

  5. Fracture strength and bending of all-ceramic and fiber-reinforced composites in inlay-retained fixed partial dentures

    Directory of Open Access Journals (Sweden)

    Serkan Saridag

    2012-06-01

    Conclusions: Zirconia-based ceramic inlay-retained fixed partial dentures demonstrated the highest fracture strength. The fiber-reinforced composite inlay-retained fixed partial dentures demonstrated higher bending values than did the all-ceramic inlay-retained fixed partial dentures.

  6. Fixed Points of α-Admissible Mappings on Partial Metric Spaces

    Directory of Open Access Journals (Sweden)

    İncı M. Erhan

    2014-01-01

    Full Text Available In this paper, a general class of α-admissible contractions on partial metric spaces is introduced. Fixed point theorems for these contractions on partial metric spaces and their consequences are stated and proved. Illustrative example is presented.

  7. Sequential provisional implant prosthodontics therapy.

    Science.gov (United States)

    Zinner, Ira D; Markovits, Stanley; Jansen, Curtis E; Reid, Patrick E; Schnader, Yale E; Shapiro, Herbert J

    2012-01-01

    The fabrication and long-term use of first- and second-stage provisional implant prostheses is critical to create a favorable prognosis for function and esthetics of a fixed-implant supported prosthesis. The fixed metal and acrylic resin cemented first-stage prosthesis, as reviewed in Part I, is needed for prevention of adjacent and opposing tooth movement, pressure on the implant site as well as protection to avoid micromovement of the freshly placed implant body. The second-stage prosthesis, reviewed in Part II, should be used following implant uncovering and abutment installation. The patient wears this provisional prosthesis until maturation of the bone and healing of soft tissues. The second-stage provisional prosthesis is also a fail-safe mechanism for possible early implant failures and also can be used with late failures and/or for the necessity to repair the definitive prosthesis. In addition, the screw-retained provisional prosthesis is used if and when an implant requires removal or other implants are to be placed as in a sequential approach. The creation and use of both first- and second-stage provisional prostheses involve a restorative dentist, dental technician, surgeon, and patient to work as a team. If the dentist alone cannot do diagnosis and treatment planning, surgery, and laboratory techniques, he or she needs help by employing the expertise of a surgeon and a laboratory technician. This team approach is essential for optimum results.

  8. Inlay fixed partial denture as a conservative approach for restoring posterior missing teeth: a clinical report.

    Science.gov (United States)

    Iglesia-Puig, Miguel A; Arellano-Cabornero, Alfonso

    2003-05-01

    Inlay fixed partial dentures luted by use of adhesive procedures offer a clinical alternative for the restoration of single missing posterior teeth. The introduction of ceromers and fiber-reinforced composites and the continuous improvement of adhesive systems and luting agents make this type of restoration possible, offering good aesthetic and functional results. The procedure is minimally invasive and conservative. This clinical report reviews the factors influencing the diagnosis and the clinical indications for an inlay fixed partial denture. In addition, a patient treatment is presented to illustrate the clinical procedures involved.

  9. Management of long span partially edentulous maxilla with fixed removable denture prosthesis

    Directory of Open Access Journals (Sweden)

    Mahilan I Jeyavalan

    2012-01-01

    Full Text Available Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis.

  10. Removable partial denture assisted by implant-retained fixed prosthesis opposing implant-retained overdenture.

    Science.gov (United States)

    Nam, Hyun-seok; Song, Kwang-yeob; Park, Ju-mi; Oh, Won-suk

    2012-01-01

    Restoring an edentulous mouth is a challenge when the patient has both high esthetic expectations and financial limitations. This case report describes the prosthodontic management of an elderly edentulous patient with a maxillary anterior implant-supported fixed partial denture in conjunction with a distal extension-base removable partial denture opposing a mandibular implant-retained overdenture. The patient's clinical outcome after 30 months is presented.

  11. On 0-Complete Partial Metric Spaces and Quantitative Fixed Point Techniques in Denotational Semantics

    Directory of Open Access Journals (Sweden)

    N. Shahzad

    2013-01-01

    Full Text Available In 1994, Matthews introduced the notion of partial metric space with the aim of providing a quantitative mathematical model suitable for program verification. Concretely, Matthews proved a partial metric version of the celebrated Banach fixed point theorem which has become an appropriate quantitative fixed point technique to capture the meaning of recursive denotational specifications in programming languages. In this paper we show that a few assumptions in statement of Matthews fixed point theorem can be relaxed in order to provide a quantitative fixed point technique useful to analyze the meaning of the aforementioned recursive denotational specifications in programming languages. In particular, we prove a new fixed point theorem for self-mappings between partial metric spaces in which the completeness has been replaced by 0-completeness and the contractive condition has been weakened in such a way that the new one best fits the requirements of practical problems in denotational semantics. Moreover, we provide examples that show that the hypothesis in the statement of our new result cannot be weakened. Finally, we show the potential applicability of the developed theory by means of analyzing a few concrete recursive denotational specifications, some of them admitting a unique meaning and others supporting multiple ones.

  12. Verification of finite element analysis of fixed partial denture with in vitro electronic strain measurement.

    Science.gov (United States)

    Wang, Gaoqi; Zhang, Song; Bian, Cuirong; Kong, Hui

    2016-01-01

    The purpose of the study was to verify the finite element analysis model of three-unite fixed partial denture with in vitro electronic strain analysis and analyze clinical situation with the verified model. First, strain gauges were attached to the critical areas of a three-unit fixed partial denture. Strain values were measured under 300 N load perpendicular to the occlusal plane. Secondly, a three-dimensional finite element model in accordance with the electronic strain analysis experiment was constructed from the scanning data. And the strain values obtained by finite element analysis and in vitro measurements were compared. Finally, the clinical destruction of the fixed partial denture was evaluated with the verified finite element analysis model. There was a mutual agreement and consistency between the finite element analysis results and experimental data. The finite element analysis revealed that failure will occur in the veneer layer on buccal surface of the connector under occlusal force of 570 N. The results indicate that the electronic strain analysis is an appropriate and cost saving method to verify the finite element model. The veneer layer on buccal surface of the connector is the weakest area in the fixed partial denture. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  13. Clinical studies of fiber-reinforced resin-bonded fixed partial dentures: a systematic review.

    NARCIS (Netherlands)

    Heumen, C.C.M. van; Kreulen, C.M.; Creugers, N.H.J.

    2009-01-01

    In the past decade, follow-up studies on fiber-reinforced composite fixed partial dentures (FRC FPDs) have been described. Combining the results of these studies to draw conclusions about the effectiveness of FRC FPDs is challenging. The objective of this systematic review was to obtain survival

  14. A Contraction Fixed Point Theorem in Partially Ordered Metric Spaces and Application to Fractional Differential Equations

    Directory of Open Access Journals (Sweden)

    Xiangbing Zhou

    2012-01-01

    Full Text Available We generalize a fixed point theorem in partially ordered complete metric spaces in the study of A. Amini-Harandi and H. Emami (2010. We also give an application on the existence and uniqueness of the positive solution of a multipoint boundary value problem with fractional derivatives.

  15. In vitro comparative evaluation of mechanical properties of temporary restorative materials used in fixed partial denture

    OpenAIRE

    D Saisadan; P Manimaran; P K Meenapriya

    2016-01-01

    Introduction: Materials used to fabricate provisional restorations can be classified as acrylics or resin composites. Provisional crows can be either prefabricated or custom made. Acrylics: These materials have been used to fabricate provisional restorations since the 1930s and usually available as powder and liquid. They are the most commonly used materials today for both single-unit and multiple-unit restorations. In general, their popularity is due to their low cost, acceptable esthetics, ...

  16. Immediate Loading of Implants in the Edentulous Maxilla with a Fixed Provisional Restoration without Bone Augmentation: A Report on 5-Year Outcomes Data Obtained from a Prospective Clinical Trial.

    Science.gov (United States)

    Toljanic, Joseph A; Ekstrand, Karl; Baer, Russell A; Thor, Andreas

    2016-01-01

    Successful immediate loading of implants in the edentulous maxilla has been previously reported. The purpose of this 5-year prospective study was to further assess long-term outcomes following immediate loading of implants in the edentulous maxilla with fixed provisional restorations without the use of bone augmentation procedures. Subjects with edentulous maxillary arches each received six implants placed in native bone without augmentation. Where insufficient posterior bone volume existed, angled implant placement was employed. Fixed provisional restorations were delivered within 24 hours of implant placement. Implant placement locations, insertion torque values, and implant dimensions were recorded. Definitive fixed prostheses were placed within 24 weeks following implantation. Baseline implant site marginal bone levels were measured using periapical radiographs. Baseline peri-implant plaque and bleeding scores were obtained. Subjects were examined 6 months after implant placement and then annually for 5 years with follow-up periapical radiographs and plaque/bleeding scores obtained. Fifty-one subjects received a total of 306 implants. Forty subjects with 232 implants returned for the final follow-up appointment representing a 5-year implant survival proportion of 93% with a mean marginal bone loss of 0.44 ± 1.25 mm for this group. Thirty-nine of these 40 subjects continued to function with fixed restorations with the remaining subject functioning with a non-implant-retained removable prosthesis. Within the limitations of this study, predictable long-term implant rehabilitation outcomes were demonstrated for the edentulous maxilla using an immediate loading protocol without bone augmentation.

  17. Common fixed point theorems via generalized condition (B in quasi-partial metric space and applications

    Directory of Open Access Journals (Sweden)

    Tomar Anita

    2017-11-01

    Full Text Available The aim of this paper is to introduce generalized condition (B in a quasi-partial metric space acknowledging the notion of Künzi et al. [Künzi H.-P. A., Pajoohesh H., Schellekens M. P., Partial quasi-metrics, Theoret. Comput. Sci., 2006, 365, 237-246] and Karapinar et al. [Karapinar E., Erhan M.,Öztürk A., Fixed point theorems on quasi-partial metric spaces, Math. Comput.Modelling, 2013, 57, 2442-2448] and to establish coincidence and common fixed point theorems for twoweakly compatible pairs of self mappings. In the sequelwe also answer affirmatively two open problems posed by Abbas, Babu and Alemayehu [Abbas M., Babu G. V. R., Alemayehu G. N., On common fixed points of weakly compatible mappings satisfying generalized condition (B, Filomat, 2011, 25(2, 9-19]. Further in the setting of a quasi-partial metric space, the results obtained are utilized to establish the existence and uniqueness of a solution of the integral equation and the functional equation arising in dynamic programming. Our results are also justified by explanatory examples supported with pictographic validations to demonstrate the authenticity of the postulates.

  18. A fixed partial appliance approach towards treatment of anterior single tooth crossbite: Report of two cases

    Directory of Open Access Journals (Sweden)

    M Gawthaman

    2017-01-01

    Full Text Available Crossbite can be treated using both removable and fixed appliances. This paper describes the report of two cases by a method of treating anterior single tooth in crossbite which is locked out of arch form with a simple fixed partial appliance. Orthodontic treatment was initiated by creating space for the locked out incisor using open coil spring and further corrected using MBT brackets and nitinol archwire for alignment. Treatment goals were achieved, and esthetics and occlusion were maintained postoperatively. Treatment objectives were obtained within a short duration using this technique, and there was an improvement in patients' smile.

  19. Fixed point results of locally contractive mappings in ordered quasi-partial metric spaces.

    Science.gov (United States)

    Shoaib, Abdullah; Arshad, Muhammad; Ahmad, Jamshaid

    2013-01-01

    Fixed point results for a self-map satisfying locally contractive conditions on a closed ball in an ordered 0-complete quasi-partial metric space have been established. Instead of monotone mapping, the notion of dominated mappings is applied. We have used weaker metric, weaker contractive conditions, and weaker restrictions to obtain unique fixed points. An example is given which shows that how this result can be used when the corresponding results cannot. Our results generalize, extend, and improve several well-known conventional results.

  20. An optical coherence tomography investigation of materials defects in ceramic fixed partial dental prostheses

    Science.gov (United States)

    Sinescu, Cosmin; Negrutiu, Meda; Hughes, Michael; Bradu, Adrian; Todea, Carmen; Rominu, Mihai; Laissue, Philippe L.; Podoleanu, Adrian Gh.

    2008-04-01

    Metal ceramic and integral ceramic fixed partial prostheses are mainly used in the frontal part of the dental arch because for esthetics reasons. The masticatory stress may induce fractures of the bridges. There are several factors that are associated with the stress state created in ceramic restorations, including: thickness of ceramic layers, mechanical properties of the materials, elastic modulus of the supporting substrate material, direction, magnitude and frequency of applied load, size and location of occlusal contact areas, residual stresses induced by processing or pores, restoration-cement interfacial defects and environmental defects. The fractures of these bridges lead to functional, esthetic and phonetic disturbances which finally render the prosthetic treatment inefficient. The purpose of this study is to evaluate the capability of optical coherence tomography (OCT) in detection and analysis of possible material defects in metal-ceramic and integral ceramic fixed partial dentures.

  1. Design Of a Fixed-Dome Ferrocement Biodigester Built Partiall y Underground

    OpenAIRE

    Marianela de la Caridad Ortiz Alvarez; Hugo Rafael Wainshtok Rivas; Henry Hernández Sotomayor

    2016-01-01

    The analysis, structural design and constructive sequence of a fixed-dome biodigester built partially underground and using ferrocement as construction material under normal work conditions is in this paper developed. The biodigester capacity is 24 m3 and it is composed by a semispherical dome (cover), cylindricalwalls (body) and a circular slab(bottom). The biodigester using ferrocement as construction materialis in agreement with the service guaranty requirements settled for the established...

  2. [Transformation of sulfur forms during coal pyrolysis and partial gasification in a fixed bed reactor].

    Science.gov (United States)

    Li, Bin; Cao, Yan; Zhang, Jianmin; Huang, Jiejie; Wang, Yang; Chen, Fuyan

    2003-03-01

    The development of various process to the pre-desulfurization of coal was drawn more attention. In present study, the transformation of sulfur forms of three different ranks high sulfur coals during coal pyrolysis and partial gasification were investigated in a fixed bed reactor. The sulfur and carbon content analysis of original coal and coal char produced were determined by LECO SC-444 and wet chemical analysis according to Sugawara's method. The results showed that half of inorganic sulfur and partial of organic sulfur were removed during coal pyrolysis. And the sulfur removal was much more than carbon during pyrolysis process; and the sulfur in the coal char, especially the sulfide sulfur was removed completely during partial gasification process for both Datong coal and Xishan coal, the degree of sulfide sulfur removal could be increased with increasing temperature. At the same time, the results of Yima coal showed that the effect of fixed-sulfur by alkaline metals increased when the temperature was higher than 700 degrees C, which attribute to the increase of the fixed sulfur reaction rate and the decrease of mass-transfer limitation.

  3. Microspectral analysis with laser in microleakage evaluation between infrastructure and veneer materials in fixed partial dentures

    Science.gov (United States)

    Negrutiu, Meda L.; Sinescu, Cosmin; Draganescu, Gheorghe; Todea, Carmen; Dodenciu, Dorin; Rominu, Roxana

    2008-02-01

    The microleakage at the interface between the metal infrastructure and the veneering part of the fixed partial dentures are a common problem of aesthetic dentistry. It is possible to use the method of laser microspectral analysis for investigations of microleakage at the metal-veneering material interfaces in fixed partial prostheses. The laser microspectral analysis device LMA-10 (Carl Zeiss, Jena) was used equipped with a diffraction spectrometer PGS-2 (Carl Zeiss, Jena). Different fixed partial dentures were used to determine the microleakage between the metal infrastructure and the veneering material. The distribution of chemical elements at interface infiltration was investigated, making a series of craters and establishing the spectra of the vapours emitted from the craters. Data was gathered in various tables of chemical elements showing the quality and the quantity of microleakage. The laser microspectral analysis is a punctual method of analysis, which allows to investigate small quantities of materials of around 0.1 μg. This method allows to establish the content of atoms and molecules and to perform semi-quantitative and quantitative analysis. By this method it is possible to establish trace elements, i. e. with concentration of ppm (parts per million).

  4. Effect of polyester fiber reinforcement on the mechanical properties of interim fixed partial dentures

    Directory of Open Access Journals (Sweden)

    N. Gopichander

    2015-10-01

    Conclusion: Within the limitations of this study, polyester fiber reinforcements improved the mechanical properties of heat-polymerized PMMA, cold-polymerized PMMA, and bis-acrylic provisional FPD materials.

  5. In vitro comparative evaluation of mechanical properties of temporary restorative materials used in fixed partial denture

    Directory of Open Access Journals (Sweden)

    D Saisadan

    2016-01-01

    Full Text Available Introduction: Materials used to fabricate provisional restorations can be classified as acrylics or resin composites. Provisional crows can be either prefabricated or custom made. Acrylics: These materials have been used to fabricate provisional restorations since the 1930s and usually available as powder and liquid. They are the most commonly used materials today for both single-unit and multiple-unit restorations. In general, their popularity is due to their low cost, acceptable esthetics, and versatility. Composites: Composite provisional materials use bis-acryl resin, a hydrophobic material that is similar to bis-GMA. Composites are available as auto-polymerized, dualpolymerized and visible light polymerized. Preformed Crowns: Preformed provisional crowns or matrices usually consist of tooth-shaped shells of plastic, cellulose acetate or metal. They are commercially available in various tooth sizes and are usually selected for a particular tooth anatomy. They are commonly relined with acrylic resin to provide a more custom fit before cementation, but the plastic and metal crown shells can also be cemented directly onto prepared teeth. Aims and Objectives: The aim of this study is to choose a material to serve as a better interim prosthesis and to compare three different properties – flexural strength, compressive strength, and color stability. Materials and Methods: The samples were made with three different provisional materials (Revotek LC, Protemp 4, TemSpan. Result: It was inferred from the study that no one material was superior in all three tested parameters.

  6. In vitro comparative evaluation of mechanical properties of temporary restorative materials used in fixed partial denture.

    Science.gov (United States)

    Saisadan, D; Manimaran, P; Meenapriya, P K

    2016-10-01

    Materials used to fabricate provisional restorations can be classified as acrylics or resin composites. Provisional crows can be either prefabricated or custom made. These materials have been used to fabricate provisional restorations since the 1930s and usually available as powder and liquid. They are the most commonly used materials today for both single-unit and multiple-unit restorations. In general, their popularity is due to their low cost, acceptable esthetics, and versatility. Composite provisional materials use bis-acryl resin, a hydrophobic material that is similar to bis-GMA. Composites are available as auto-polymerized, dualpolymerized and visible light polymerized. Preformed provisional crowns or matrices usually consist of tooth-shaped shells of plastic, cellulose acetate or metal. They are commercially available in various tooth sizes and are usually selected for a particular tooth anatomy. They are commonly relined with acrylic resin to provide a more custom fit before cementation, but the plastic and metal crown shells can also be cemented directly onto prepared teeth. The aim of this study is to choose a material to serve as a better interim prosthesis and to compare three different properties - flexural strength, compressive strength, and color stability. The samples were made with three different provisional materials (Revotek LC, Protemp 4, TemSpan). It was inferred from the study that no one material was superior in all three tested parameters.

  7. Emergency direct fabrication of a resin fixed partial denture by using a ceramometal crown with reinforcing woven polyethylene ribbon as a pontic.

    Science.gov (United States)

    Miller, T E; Rudo, D N

    1995-01-01

    In this emergency case of a fractured tooth, immediate short-term treatment was necessary to relieve pain and replace a missing coronal portion of the maxillary central incisor. The need to remove additional fractured root fragments subgingivally precluded accessibility to the remaining root for conventional restorative procedures. The patient could not decide which course of treatment to accept, so a fixed partial denture was fabricated, with the ceramometal crown restoration as a provisional pontic splinted to the adjacent teeth. Restoring and reinforcing the posterior composite splint with a gas plasma-treated woven polyethylene ribbon has been detailed and illustrated. This ribbon material reputed to be 10 times stronger than steel by volume, is a true reinforcing material because it is woven. Mechanically, it becomes an integral part of the splint. Because it is gas plasma-treated, the superficial layer, when placed in BIS-GMA or polymethyl methacrylate, reacts chemically with the resin. The pliable, memory-free fiber--together with the open, woven, lacelike, lock stitch leno--allows the ribbon to follow the contours of the teeth and dental arch easily. The ribbon design reduces and dissipates forces exerted onto the splinting resin. The neutral color of the material permits it to have a chameleonlike effect on the color of the resin into which it is positioned. This ribbon product has been used in other dental applications: periodontal splinting, orthodontic retention, indirect composite fixed partial dentures, long-term temporary restorations with applicability in implant treatments, repair and conversion of prostheses, and reinforcing endodontically treated teeth, and complete dentures and orthodontic retainers when weaknesses are anticipated, such as shallow palatal vaults of complete dentures against a full complement of mandibular natural teeth, and the horseshoe mandibular removable modified Hawley retainer.

  8. Maxillary rehabilitation using fixed and removable partial dentures with attachments: a clinical report.

    Science.gov (United States)

    dos Santos Nunes Reis, José Maurício; da Cruz Perez, Luciano Elias; Alfenas, Bruna Fernandes Moreira; de Oliveira Abi-Rached, Filipe; Filho, João Neudenir Arioli

    2014-01-01

    Despite requiring dental crown preparation and possible root canal treatment, besides the difficulty of clinical and laboratory repairs, and financial burden, the association between fixed (FPD) and removable partial dentures (RPD) by means of attachments is an important alternative for oral rehabilitation, particularly when the use of dental implants and FPDs is limited or not indicated. Among the advantages of attachment-retained RPDs are the improvements in esthetics and biomechanics, as well as correction of the buccal arrangement of anterior teeth in Kennedy Class III partially edentulous arches. This article describes the treatment sequence and technique for the use of attachments in therapy combining FPD/RPD. © 2013 by the American College of Prosthodontists.

  9. Clinical evaluation of conventional cantilever and resin bonded cantilever fixed partial dentures: a comparative study.

    Science.gov (United States)

    Prasanna, B G; Reddy, K Kesava; Harsha, T V Shree; Ramesh, G C

    2012-11-01

    Ever since the introduction of the minimal preparation fixed partial dentures, the major concern of the clinicians has been its longevity. The objective of the present study was to compare the clinical performance of resin bonded cantilever bridges with conventional cantilever bridges for a period of 1 year and to evaluate the periodontal changes of abutment teeth using radio visio graphy. Fourteen patients with missing first or second premolar were selected for the study. The patients were divided into 2 groups, conventional cantilever group and resin bonded cantilever group. The results were analyzed using Student's t test and Mann-Whitney U test. The clinical success rate for both the groups was 100%. The amount of bone loss at 6 months for conventional group was 0.11 mm and for resin bonded bridge group was 0.10 mm. The amount of bone loss at 1 year for conventional cantilever group was 0.14 mm and for resin bonded fixed partial denture group was 0.16 mm. There was no statistical difference between both the groups. The results showed that the resin bonded cantilever bridges can be used for the treatment of missing posterior tooth.

  10. The teaching of fixed partial dentures in undergraduate dental schools in Ireland and the United Kingdom.

    Science.gov (United States)

    Lynch, C D; Singhrao, H; Addy, L D; Gilmour, A S M

    2010-12-01

    All areas of the practice of dentistry are evolving at a considerable pace. One area in particular which has seen a rapid revolution is the oral rehabilitation of partially dentate adults. The aim of this study was to describe the contemporary teaching of fixed partial dentures (FPDs) in dental schools in Ireland and the United Kingdom. An online questionnaire which sought information in relation to the current teaching of FPDs was developed and distributed to 15 Irish and UK dental schools with undergraduate teaching programmes in Spring 2009. Responses were received from 12 schools (response rate=80%). All schools offer teaching programmes in relation to FPDs. The number of hours devoted to pre-clinical/phantom head teaching of FPDs ranged from 3 to 42h (mean: 16h). The staff/student ratio for pre-clinical teaching courses in FPDs ranged from 1:6 to 1:18 (mode: 1:12). Cantilever resin-retained FPDs were the most popular type of FPD provided clinically (average=0·83 per school; range=1-2). Five schools (42%) report that they have requirements (e.g. targets, quotas, competencies) which students must complete prior to graduation in relation to FPDs. Fixed partial dentures form an important part of the undergraduate teaching programme in UK and Irish dental schools. While this teaching is subjected to contemporary pressures such as lack of curriculum time and a lack of available clinical facilities and teachers, there is evidence that teaching programmes in this area are evolving and are sensitive to current clinical practice trends and evidence-based practice. © 2010 Blackwell Publishing Ltd.

  11. Fixed point and anomaly mediation in partial {\\boldsymbol{N}}=2 supersymmetric standard models

    Science.gov (United States)

    Yin, Wen

    2018-01-01

    Motivated by the simple toroidal compactification of extra-dimensional SUSY theories, we investigate a partial N = 2 supersymmetric (SUSY) extension of the standard model which has an N = 2 SUSY sector and an N = 1 SUSY sector. We point out that below the scale of the partial breaking of N = 2 to N = 1, the ratio of Yukawa to gauge couplings embedded in the original N = 2 gauge interaction in the N = 2 sector becomes greater due to a fixed point. Since at the partial breaking scale the sfermion masses in the N = 2 sector are suppressed due to the N = 2 non-renormalization theorem, the anomaly mediation effect becomes important. If dominant, the anomaly-induced masses for the sfermions in the N = 2 sector are almost UV-insensitive due to the fixed point. Interestingly, these masses are always positive, i.e. there is no tachyonic slepton problem. From an example model, we show interesting phenomena differing from ordinary MSSM. In particular, the dark matter particle can be a sbino, i.e. the scalar component of the N = 2 vector multiplet of {{U}}{(1)}Y. To obtain the correct dark matter abundance, the mass of the sbino, as well as the MSSM sparticles in the N = 2 sector which have a typical mass pattern of anomaly mediation, is required to be small. Therefore, this scenario can be tested and confirmed in the LHC and may be further confirmed by the measurement of the N = 2 Yukawa couplings in future colliders. This model can explain dark matter, the muon g-2 anomaly, and gauge coupling unification, and relaxes some ordinary problems within the MSSM. It is also compatible with thermal leptogenesis.

  12. Relevance of variations in the opposing dentition for the functionality of fixed and removable partial dentures: a systematic review.

    Science.gov (United States)

    Pommer, Bernhard; Krainhöfner, Martin; Watzek, Georg; Tepper, Gabor; Dintsios, Charalabos-Markos

    2012-01-01

    The aim of this systematic review was to evaluate the functionality of fixed and removable partial dentures as test interventions in relation to variations in the opposing dentition and their prosthetic restoration. The abstracts identified in the respective databases were screened independently by two investigators. RCTs and uncontrolled studies were considered, provided the patients were included consecutively and the confounding variables were adequately monitored. Seventeen papers were included. The study and publication quality was assessed using a "biometric quality" tool showing an overall poor quality. The reported outcomes, such as survival rates, were in each case obtained from a single study. Two possible trends could be deduced for the endpoint longevity: (a) the first trend in favor of removable partial dentures, compared to fixed partial dentures, with a fully edentulous opposing arch fitted with a removable prosthesis; (b) the second trend in favor of implant-supported partial dentures, compared to conventionally fixed partial dentures, with natural opposing dentition or with a removable partial denture in the opposing arch. No evidence could be generated as to whether, and if so how, variations in the opposing dentition have a bearing on the decision to fit a partially edentulous arch with a fixed or removable partial denture.

  13. Relevance of Variations in the Opposing Dentition for the Functionality of Fixed and Removable Partial Dentures: A Systematic Review

    Science.gov (United States)

    Pommer, Bernhard; Krainhöfner, Martin; Watzek, Georg; Tepper, Gabor; Dintsios, Charalabos-Markos

    2012-01-01

    The aim of this systematic review was to evaluate the functionality of fixed and removable partial dentures as test interventions in relation to variations in the opposing dentition and their prosthetic restoration. The abstracts identified in the respective databases were screened independently by two investigators. RCTs and uncontrolled studies were considered, provided the patients were included consecutively and the confounding variables were adequately monitored. Seventeen papers were included. The study and publication quality was assessed using a “biometric quality” tool showing an overall poor quality. The reported outcomes, such as survival rates, were in each case obtained from a single study. Two possible trends could be deduced for the endpoint longevity: (a) the first trend in favor of removable partial dentures, compared to fixed partial dentures, with a fully edentulous opposing arch fitted with a removable prosthesis; (b) the second trend in favor of implant-supported partial dentures, compared to conventionally fixed partial dentures, with natural opposing dentition or with a removable partial denture in the opposing arch. No evidence could be generated as to whether, and if so how, variations in the opposing dentition have a bearing on the decision to fit a partially edentulous arch with a fixed or removable partial denture. PMID:23193407

  14. Alternative complete-arch cement-retained implant-supported fixed partial denture.

    Science.gov (United States)

    Hofstede, T M; Ercoli, C; Hagan, M E

    1999-07-01

    Early implant prostheses designs, which used screw-retained metal and acrylic resin structures, frequently left a space between the prosthesis and the soft tissue. Common deficiencies of this design included phonetic and esthetic problems and screw loosening. Cement-retained implant prostheses are also used in partially and completely edentulous patients, and are thought to have optimal occlusion and esthetics. Moreover, cement-retained prostheses may induce less stress on the implant, thereby maximizing the possibility of a passive fit. Porcelain fused to metal prostheses have been used mostly in partially edentulous situations. Recently, complete-arch porcelain fused to metal prostheses that replace hard and soft tissue have been used and, although this restoration can have excellent esthetics, there are disadvantages such as high cost, potential framework distortion during fabrication, and difficulty in repairing fractures of in-service porcelain. This article describes an alternative technique for the fabrication of a complete-arch, cement-retained, metal-acrylic resin implant-supported fixed partial denture. When compared with porcelain fused to metal complete-arch restorations, this prostheses is esthetic, has excellent retention and stability, yet is relatively inexpensive to fabricate, and requires less laboratory skill.

  15. Single Tooth Replacement Using InCeram Resin Bonded Fixed Partial Denture: A Clinical Report.

    Directory of Open Access Journals (Sweden)

    Elnaz Moslehifard

    2014-02-01

    Full Text Available This clinical report describes a treatment option for replacement of a missing mandibular anterior tooth using InCeram resin bonded fixed partial denture (RBFPD. The conventional approach for replacing mandibular incisors dictates the placement of either a conventional porcelain-fused-to-metal (PFM bridge, Maryland bridge, or fiber-reinforced composite veneer bridge and several appearance-related disadvantages have been reported in the use of a prosthesis that incorporates a metal substructure. The InCeram bridge is a minimally invasive restoration and eliminates undesirable incisal graying frequently observed in metal RBFPDs. This method was successfully clinically applied to overcome shortcomings of other approaches that may require a minimal invasive technique to preserve lasting sound tooth structure.

  16. Comparison of Treatment Outcomes in Partially Edentulous Patients with Implant-Supported Fixed Prostheses and Removable Partial Dentures.

    Science.gov (United States)

    Nogawa, Toshifumi; Takayama, Yoshiyuki; Ishida, Keita; Yokoyama, Atsuro

    The aim of this study was to compare masticatory performance, occlusal force, and oral health-related quality of life (OHRQoL) in patients with mandibular distal-extension edentulism between those with implant-supported fixed prostheses (ISFPs) and those with removable partial dentures (RPDs), and to evaluate relationships among them. Subjects were recruited from patients using ISFPs or RPDs for mandibular distal-extension edentulism. Masticatory performance was evaluated based on the glucose extracted from chewed gummy jelly. Occlusal force was measured with a pressure-sensitive sheet, and data were subjected to computer analysis. The Japanese version of the Oral Health Impact Profile (OHIP-J) was used to evaluate OHRQoL. The masticatory performance, occlusal force, and OHIP-J scores of the ISFP and RPD groups were compared using the Wilcoxon rank-sum test. The relationships among the variables were analyzed using the Spearman rank correlation coefficient test. Multivariate logistic regression analysis was employed with the OHIP-J score as a dependent variable. Nineteen patients with ISFPs and 25 patients with RPDs participated in this study. No significant difference was observed between the two groups with regard to masticatory performance and occlusal force. The OHIP-J score was significantly lower in the ISFP group than in the RPD group. The OHIP-J score had no significant correlation with masticatory performance, but was significantly correlated with occlusal force and the prosthetic method. Multivariate logistic regression analysis showed that younger age, RPDs, and lower occlusal force were significantly associated with a higher OHIP-J summary score. The present results suggest that the difference in masticatory performance and occlusal force between ISFPs and RPDs is small, but ISFPs are superior to RPDs with regard to OHRQoL in patients with mandibular distal-extension edentulism. In addition, there appears to be a slight correlation between the OHIP

  17. Partial relay selection in underlay cognitive networks with fixed gain relays

    KAUST Repository

    Hussain, Syed Imtiaz

    2012-05-01

    In a communication system with multiple cooperative relays, selecting the best relay utilizes the available spectrum more efficiently. However, selective relaying poses a different problem in underlay cognitive networks compared to the traditional cooperative networks due to interference thresholds to the primary users. In most cases, a best relay is the one which provides the maximum end-to-end signal to noise ratio (SNR). This approach needs plenty of instantaneous channel state information (CSI). The CSI burden could be reduced by partial relay selection. In this paper, a partial relay selection scheme is presented and analyzed for an underlay cognitive network with fixed gain relays operating in the vicinity of a primary user. The system model is adopted in a way that each node needs minimal CSI to perform its task. The best relay is chosen on the basis of maximum source to relay link SNR which then forwards the message to the destination. We derive closed form expressions for the received SNR distributions, system outage, probability of bit error and average channel capacity of the system. The derived results are confirmed through simulations. © 2012 IEEE.

  18. Flexural strength of small connector designs of zirconia-based partial fixed dental prostheses.

    Science.gov (United States)

    Hamza, Tamer A; Attia, Mazen A; El-Hossary, Mohamed Mahmoud Khalil; Mosleh, Ihab E; Shokry, Tamer E; Wee, Alvin G

    2016-02-01

    Partial fixed dental prostheses with a small connector size are required for optimal esthetics and limited interarch space; however, final strength is endangered. The purpose of this in vitro study was to evaluate the effect of different connector designs on the flexural strength of simulated 3-unit partial fixed dental prostheses made of yttria-stabilized tetragonal zirconia polycrystalline using computer-aided design and computer-aided manufacturing technology. To simulate a 3-unit partial fixed dental prosthesis, 20 rectangular bar-shaped specimens were fabricated with dimensions of 4 ± 0.05 mm (H) × 4 ± 0.05 mm (W) × 30 0.5 mm (L). Each bar specimen had 2 constricted parts on both sides, representing the connector and defining a central pontic of 10 ± 0.10 mm in length. The specimens were divided into 4 groups according to the connector diameter and design, as follows: SR: 2 mm (H) × 3 mm (W) round 0.6 mm radius of curvature; SS: 2 mm (H) × 3 mm (W) sharp 0.1 mm radius of curvature; CR: 3 mm (H) × 3 mm (W) round 0.6 mm radius of curvature; and CS: 3 mm (H) × 3 mm (W) sharp 0.1 mm radius of curvature. An additional 5 specimens were fabricated with no constriction and served as the control group. The specimens were subjected to a 3-point flexural strength test in a universal testing machine with a crosshead speed of 0.5 mm/min until failure. Scanning electron microscopic and photomicrograph images were used to examine the fracture surfaces. Two-way ANOVA and the Tukey-Kramer post hoc test were used to analyze the data (α = .05). The mean flexural strength for SR 2 mm (H) × 3 mm (W) round 0.6 mm radius of curvature (583.6 ± 49.7 MPa) was significantly higher than that of SS, which was 2 mm (H)× 3 mm (W) sharp 0.1 mm radius of curvature (502.8 ± 23.3 MPa). Similarly, the mean flexural strength for CR was 3 mm (H) × 3 mm (W) round 0.6 mm radius of curvature (682.9 ± 36.8), which was significantly higher than that of CC, 3 mm (H) × 3 mm (W) sharp 0

  19. Multiple fixed point theorems for contractive and Meir-Keeler type mappings defined on partially ordered spaces with a distance

    Directory of Open Access Journals (Sweden)

    Mitrofan M Choban

    2017-10-01

    Full Text Available We introduce and study a general concept of multiple fixed point for mappings defined on partially ordered distance spaces in the presence of a contraction type condition and appropriate monotonicity properties. This notion and the obtained results complement the corresponding ones from [M. Choban, V. Berinde, A general concept of multiple fixed point for mappings defined on  spaces with a distance, Carpathian J. Math. 33 (2017, no. 3, 275--286] and also simplifies some concepts of multiple fixed point considered by various authors in the last decade or so.

  20. Fracture resistance of three-unit zirconia fixed partial denture with modified framework.

    Science.gov (United States)

    Partiyan, Arthur; Osman, Essam; Rayyan, Mohammad M; Aboushelib, Moustafa; Ibrahim, Ahmed; Jimbo, Ryo

    2017-01-01

    Obtaining ideal prosthetic framework design is at times hindered by anatomical limitations in the posterior region that might increase the risk for zirconia restoration fracture. Modification such as increasing the bulk thickness especially in the connector region could result in strengthening the zirconia framework. Three-unit zirconia fixed partial dentures replacing mandibular molars were fabricated using the following two techniques: CAD/CAM technology and manual copy milling. Modified framework with unveneered full thickness connectors were designed and fabricated with the aforementioned methods. Conventional frameworks (0.5 mm thick with rounded 3 mm connectors) served as control (N = 20). After cementation on epoxy dies, the frameworks were loaded to fracture in a universal testing machine. Fractured surfaces were prepared for examination using scanning electron microscopy. Statistical analysis revealed significant differences in fracture resistance between conventional and modified framework design for both fabrication techniques tested. SEM examination indicated that critical crack originated at the tensile surface of the connectors for conventional frameworks. The critical crack for modified frameworks occurred on the axial wall of the abutments. The modification of the zirconia framework design presented significant improvement of the fracture resistance compared to the conventional design.

  1. Fracture Strength and Bending of Fiber-Reinforced Composites and Metal Frameworks in Fixed Partial Dentures

    Directory of Open Access Journals (Sweden)

    M. Sadeghi

    2008-09-01

    Full Text Available Objective: This in vitro study evaluated the fracture strength and bending amount of twotypes of fiber reinforced composite (FRC and cast metal frameworks used for fabrication of inlay fixed partial dentures (IFPDs.Materials and Methods: Seventy-two extracted first maxillary premolars and molars (36 each were embedded in acrylic resin to represent a missing of second maxillary premolar. FRC IFPDs were fabricated using Stick and Fiber-Braid fiber bundles and IFPDs using cast metal alloy (12 for each group. The specimens were stored for 2 weeks at 37°C(SD=1 in distilled water, thermocycled (5-55°C, x 2500 and statically loaded to fracture. The initial bending prior to fracture was evaluated. The data were analyzed using paired t-test and ANOVA test.Results: The fracture strength was significantly higher in the FRC groups (P<0.05; also, the fracture strength was significantly higher in Stick group than Fiber-Braid group (P<0.05. The amount of bending was significantly greater in the FRC groups (P<0.05. The amount of difference in bending between the two groups of FRC was not statistically significant.Conclusion: Within the limits of this in vitrostudy, the results suggest that the FRC IFPDs can be used as a conservative, esthetic alternative to the IFPDs with cast metal frameworks. The results of this study should be confirmed by long-term clinical investigations.

  2. Theoretical axial wall angulation for rotational resistance form in an experimental-fixed partial denture.

    Science.gov (United States)

    Bowley, John Francis; Kaye, Elizabeth Krall; Garcia, Raul Isidro

    2017-08-01

    The aim of this study was to determine the influence of long base lengths of a fixed partial denture (FPD) to rotational resistance with variation of vertical wall angulation. Trigonometric calculations were done to determine the maximum wall angle needed to resist rotational displacement of an experimental-FPD model in 2-dimensional plane. The maximum wall angle calculation determines the greatest taper that resists rotation. Two different axes of rotation were used to test this model with five vertical abutment heights of 3-, 3.5-, 4-, 4.5-, and 5-mm. The two rotational axes were located on the mesial-side of the anterior abutment and the distal-side of the posterior abutment. Rotation of the FPD around the anterior axis was counter-clockwise, Posterior-Anterior (P-A) and clockwise, Anterior-Posterior (A-P) around the distal axis in the sagittal plane. Low levels of vertical wall taper, ≤ 10-degrees, were needed to resist rotational displacement in all wall height categories; 2-to-6-degrees is generally considered ideal, with 7-to-10-degrees as favorable to the long axis of the abutment. Rotation around both axes demonstrated that two axial walls of the FPD resisted rotational displacement in each direction. In addition, uneven abutment height combinations required the lowest wall angulations to achieve resistance in this study. The vertical height and angulation of FPD abutments, two rotational axes, and the long base lengths all play a role in FPD resistance form.

  3. Early complications and short-term failures of zirconia single crowns and partial fixed dental prostheses.

    Science.gov (United States)

    Pihlaja, Juha; Näpänkangas, Ritva; Raustia, Aune

    2014-10-01

    Ceramic single crowns fabricated from newer materials, especially zirconia, have shown relatively high survival rates. However, early reversible complications may increase the risk of an irreversible failure later. The purpose of the study was to evaluate the early complications and short-term failures of zirconia single crowns and partial fixed dental prostheses (FDPs) made by predoctoral dental students. Data were collected from the patient records. Altogether, 264 zirconia single crowns and 120 FDPs (342 abutments and 190 pontics) were fabricated for 173 patients between 2007 and 2010. Early complications were recorded during the prosthetic treatment phase, and short-term failures were recorded during the first year in use. The most frequent early complications were localized gingival irritation (1.9% of single crowns and 2.5% of FDP) and postoperative tooth sensitivity (0.4% of single crowns and 3.3% of FDPs). Pulp exposure during preparation was recorded in 3 abutment teeth of the FDPs. The most frequent short-term failure was chipping of the veneering porcelain (0.8% for single crowns, 0.8% for FDPs). One crown lost cementation because of poor retention (0.4%), and 2 FDPs failed because of framework fractures (1.7%). The most frequent early complications were localized gingival irritation and postoperative tooth sensitivity, and the most frequent short-term failure was chipping of the veneering porcelain. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  4. Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures.

    Science.gov (United States)

    Merıç, Gökçe; Erkmen, Erkan; Kurt, Ahmet; Eser, Atilim; özden, Ahmet Utku

    2011-11-01

    The purpose of the study was to compare the effects of two distinct collar geometries of implants on stress distribution in the bone around the implants supporting cantilever fixed partial dentures (CFPDs) as well as in the implant-abutment complex and superstructures. The three-dimensional finite element method was selected to evaluate the stress distribution. CFPDs which was supported by microthread collar structured (MCS) and non-microthread collar structured (NMCS) implants was modeled; 300 N vertical, 150 N oblique and 60 N horizontal forces were applied to the models separately. The stress values in the bone, implant-abutment complex and superstructures were calculated. In the MCS model, higher stresses were located in the cortical bone and implant-abutment complex in the case of vertical load while decreased stresses in cortical bone and implant-abutment complex were noted within horizontal and oblique loading. In the case of vertical load, decreased stresses have been noted in cancellous bone and framework. Upon horizontal and oblique loading, a MCS model had higher stress in cancellous bone and framework than the NMCS model. Higher von Mises stresses have been noted in veneering material for NMCS models. It has been concluded that stress distribution in implant-supported CFPDs correlated with the macro design of the implant collar and the direction of applied force.

  5. Fit of all-ceramic posterior fixed partial denture frameworks in vitro.

    Science.gov (United States)

    Bindl, Andreas; Mörmann, Werner H

    2007-12-01

    The objective of this study was to evaluate, by scanning electron microscopy, the marginal and internal fit of all-ceramic three-unit fixed partial denture (FPD) frames fabricated by computer-assisted design/computer-aided machining (CAD/CAM) and CAM techniques using blocks of infiltration ceramic, high-strength yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) zirconia sinter ceramic, high-strength dense sintered Y-TZP zirconia ceramic, and glass ceramic. Slip-cast infiltration ceramic was used as a traditional control. The cementation interface widths of the FPD frame copings on butt (A) shoulders of Cerec In-Ceram zirconia (A1, 53 +/- 17 microm) were smaller than those of slip-cast In-Ceram zirconia (A6, 113 +/- 25 microm). Cerec Y-TZP zirconia (A2, 53 +/- 9 pm) and DCS Y-TZP zirconia (A4, 32 +/- 6 microm) interfaces were both significantly smaller than those of Cercon Y-TZP zirconia (A5, 120 +/- 6 microm). Internally, A2 (103 +/- 14) interfaces were smaller than A4 interfaces (144 +/- 15 microm). On chamfer shoulders (B), Cerec Y-TZP zirconia (B1, 71 +/- 5 microm) interfaces were smaller than Cercon interfaces (B2, 129 +/- 38 microm); internally, B1 (80 +/- 11 microm) interfaces were smaller than B2 interfaces (130 +/- 12 microm). CAD/CAM produced better marginal and internal accuracy of fit compared to slip casting and CAM techniques.

  6. Influence of cementation variables on fatigue of simulated two-unit cantilever resin-bonded fixed partial dentures

    NARCIS (Netherlands)

    van Dalen, A.; Feilzer, A.J.; Kleverlaan, C.J.

    2008-01-01

    PURPOSE: To determine the influence of various combinations of surface pretreatment and luting cement on flexural fatigue limits of two-unit CoCr cantilever resin-bonded fixed partial dentures. METHODS: Cyclic fatigue tests were performed at 1 Hz on an ACTA fatigue tester. The staircase test method

  7. Some Common Fixed Point Theorems for F-Contraction Type Mappings in 0-Complete Partial Metric Spaces

    Directory of Open Access Journals (Sweden)

    Satish Shukla

    2013-01-01

    Full Text Available We prove some common fixed point theorems for F-contractions in 0-complete partial metric spaces. Our results extend, generalize, and unify several known results in the literature. Some examples are included which show that the generalization is proper.

  8. Five-year survival of 3-unit fiber-reinforced composite fixed partial dentures in the anterior area.

    NARCIS (Netherlands)

    Heumen, C.C.M. van; Dijken, J.W.V. van; Tanner, J.; Pikaar, R.; Lassila, L.V.; Creugers, N.H.J.; Vallittu, P.K.; Kreulen, C.M.

    2009-01-01

    OBJECTIVES: The purpose of this clinical study was to evaluate the long-term outcome of 3-unit anterior fixed partial dentures (FPDs) made of fiber-reinforced resin composite (FRC), and to identify design factors influencing the survival rate. METHODS: 52 patients (26 females, 26 males) received 60

  9. The effect of box preparation on the strength of glass fiber-reinforced composite inlay-retained fixed partial dentures

    NARCIS (Netherlands)

    Ozcan, M; Breuklander, MH; Vallittu, PK

    Statement of problem. Nonstandardized box dimensions for inlay-retained fixed partial dentures (FPDs) may result in uneven distribution of the forces on the connector region of such restorations. Purpose. The objective of this in vitro study was to evaluate the effect of box dimensions on the

  10. The effect of box preparation on the strength of glass fiber–reinforced composite inlay-retained fixed partial dentures

    NARCIS (Netherlands)

    Özcan, Mutlu; Breuklander, Marijn H.; Vallittu, Pekka K.

    2005-01-01

    Statement of problem. Nonstandardized box dimensions for inlay-retained fixed partial dentures (FPDs) may result in uneven distribution of the forces on the connector region of such restorations. Purpose. The objective of this in vitro study was to evaluate the effect of box dimensions on the

  11. An In Vivo Study on Load Distribution in Different Implant Configurations for Supporting Fixed Partial Dentures.

    Science.gov (United States)

    Kobari, Hiromori; Yoda, Nobuhiro; Chen, Junning; Kawata, Tetsuo; Sasaki, Keiichi

    2016-01-01

    The aims of this study were to develop a device for in vivo measurement of three-dimensional (3D) loads on implants and to investigate the effects of implant configuration on the load distribution under a three-unit fixed partial denture (FPD). A 67-year-old female patient with three implants (in the mandibular left second premolar, first molar, and second molar regions) was recruited. Four implant configurations for a three-unit FPD depending on the number and position of the implants were considered in this study. They included a three-implant prosthesis and three types of two-implant prosthesis: a central pontic, posterior cantilever, and anterior cantilever, with the same superstructure (splinted three crowns) for the same occlusal contact. Customized abutments and 3D piezoelectric force transducers were fixed to the implants of the four configurations with the superstructure. The loads on the implants were recorded during maximum voluntary clenching (MVC-test) and when chewing a piece of chewing gum (GUMtest). The occlusal forces on the dental arch during MVC-test with the four implant configurations did not exhibit significant differences. In the three-implant prosthesis, there were no significant differences in the mean maximum resultant load on each implant in both tests. In the central pontic, the load on the second premolar was significantly greater than that on the second molar in the MVC-test but there were no significant differences in the GUM-test. High loads were detected on the first molar in both the posterior cantilever and anterior cantilever. The highest load was detected on the first molar in the posterior cantilever during the GUMtest. The in vivo 3D load-measuring device using the piezoelectric force transducers enabled the measurement of the functional load on implants supporting a FPD. The results suggested, within the limitations of this study, that a three-implant prosthesis and central pontic provide biomechanically beneficial designs

  12. Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology

    Directory of Open Access Journals (Sweden)

    Marcia Borba

    2013-09-01

    Full Text Available The objective of the study was to measure the marginal and internal fit of zirconia-based all-ceramic three-unit fixed partial dentures (FPDs (Y-TZP - LAVA, 3M-ESPE, using a novel methodology based on micro-computed tomography (micro-CT technology. Stainless steel models of prepared abutments were fabricated to design FPDs. Ten frameworks were produced with 9 mm2 connector cross-sections using a LAVATM CAD-CAM system. All FPDs were veneered with a compatible porcelain. Each FPD was seated on the original model and scanned using micro-CT. Files were processed using NRecon and CTAn software. Adobe Photoshop and Image J software were used to analyze the cross-sectional images. Five measuring points were selected, as follows: MG - marginal gap; CA - chamfer area; AW - axial wall; AOT - axio-occlusal transition area; OA - occlusal area. Results were statistically analyzed by Kruskall-Wallis and Tukey's post hoc test (α= 0.05. There were significant differences for the gap width between the measurement points evaluated. MG showed the smallest median gap width (42 µm. OA had the highest median gap dimension (125 µm, followed by the AOT point (105 µm. CA and AW gap width values were statistically similar, 66 and 65 µm respectively. Thus, it was possible to conclude that different levels of adaptation were observed within the FPD, at the different measuring points. In addition, the micro-CT technology seems to be a reliable tool to evaluate the fit of dental restorations.

  13. A comparative finite elemental analysis of glass abutment supported and unsupported cantilever fixed partial denture.

    Science.gov (United States)

    Ramakrishaniah, Ravikumar; Al Kheraif, Abdulaziz A; Elsharawy, Mohamed A; Alsaleh, Ayman K; Ismail Mohamed, Karem M; Rehman, Ihtesham Ur

    2015-05-01

    The purpose of this study was to investigate and compare the load distribution and displacement of cantilever prostheses with and without glass abutment by three dimensional finite element analysis. Micro-computed tomography was used to study the relationship between the glass abutment and the ridge. The external surface of the maxilla was scanned, and a simplified finite element model was constructed. The ZX-27 glass abutment and the maxillary first and second premolars were created and modified. The solid model of the three-unit cantilever fixed partial denture was scanned, and the fitting surface was modified with reference to the created abutments using the 3D CAD system. The finite element analysis was completed in ANSYS. The fit and total gap volume between the glass abutment and dental model were determined by Skyscan 1173 high-energy spiral micro-CT scan. The results of the finite element analysis in this study showed that the cantilever prosthesis supported by the glass abutment demonstrated significantly less stress on the terminal abutment and overall deformation of the prosthesis under vertical and oblique load. Micro-computed tomography determined a gap volume of 6.74162 mm(3). By contacting the mucosa, glass abutments transfer some amount of masticatory load to the residual alveolar ridge, thereby preventing damage to the periodontal microstructures of the terminal abutment. The passive contact of the glass abutment with the mucosa not only preserves the health of the mucosa covering the ridge but also permits easy cleaning. It is possible to increase the success rate of cantilever FPDs by supporting the cantilevered pontic with glass abutments. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  14. Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology

    Energy Technology Data Exchange (ETDEWEB)

    Borba, Marcia; Bona, Alvaro Della, E-mail: marcia_borb@hotmail.com [Universidade de Passo Fundo (UPF), RS (Brazil). Fac. de Odontologia; Miranda Junior, Walter Gomes; Cesar, Paulo Francisco [Universidade de Sao Paulo (USP), SP (Brazil). Fac. de Odontologia. Dept. de Biomateriais e Bioquimica Oral; Griggs, Jason Allan [Department of Biomedical Materials Science, Dental School, University of Mississippi Medical Center - UMMC, Jackson, MS (United States)

    2013-09-15

    The objective of the study was to measure the marginal and internal fit of zirconia-based all-ceramic three-unit fixed partial dentures (FPDs) (Y-TZP - LAVA, 3M-ESPE), using a novel methodology based on micro-computed tomography (micro-CT) technology. Stainless steel models of prepared abutments were fabricated to design FPDs. Ten frameworks were produced with 9 mm² connector cross-sections using a LAVA® CAD-CAM system. All FPDs were veneered with a compatible porcelain. Each FPD was seated on the original model and scanned using micro-CT. Files were processed using NRecon and CTAn software. Adobe Photoshop and Image J software were used to analyze the cross sectional images. Five measuring points were selected, as follows: MG- marginal gap; CA - chamfer area; AW - axial wall; AOT - axio-occlusal transition area; OA - occlusal area. Results were statistically analyzed by Kruskall-Wallis and Tukey's post hoc test (α = 0.05). There were significant differences for the gap width between the measurement points evaluated. MG showed the smallest median gap width (42 μm). OA had the highest median gap dimension (125 μm), followed by the AOT point (105 μm). CA and AW gap width values were statistically similar, 66 and 65 μm respectively. Thus, it was possible to conclude that different levels of adaptation were observed within the FPD, at the different measuring points. In addition, the micro-CT technology seems to be a reliable tool to evaluate the fit of dental restorations. (author)

  15. Temperature rise on dentin caused by temporary crown and fixed partial denture materials: influencing factors.

    Science.gov (United States)

    Seelbach, Paul; Finger, Werner J; Ferger, Paul; Balkenhol, Markus

    2010-12-01

    Temporary crowns and fixed partial denture materials (t-c&b) generate exothermic heat during polymerization. The amount of temperature, reaching the pulp chamber, is dependent on the residual thickness of the prepared dentin as well as the volume of the t-c&b used. Hence, the aim of this study was to investigate the influence of both factors on the temperature rise at the pulpal dentin surface as well as in the bulk of the t-c&b during polymerization. Four t-c&bs (Luxatemp AM Plus, Protemp 3 Garant, Structur Premium, Trim) were used to fabricate flat cylindrical specimens (∅ 15.5mm) of different thicknesses (1, 2 and 4mm) using an over-impression placed on top of dentin discs (thickness 0.5, 1 and 2mm). Temperature was recorded at the pulpal dentin surface as well as inside the t-c&b (n=6). Data was subjected to parametric statistics (α=0.05). Peak temperatures inside the t-c&b varied between 37.0°C and 51.9°C and at the pulpal dentin side between 37.0°C and 50.6°C. The maximum temperatures registered depended significantly on the thickness of the dentin disc and t-c&b, respectively (ANOVA ptemperatures were reached 2-3 min after start of mixing (dimethacrylates) and 6 min (mono-methacrylate), respectively, whereas Trim exhibited significantly higher peak temperatures (ptemperature rise may become critical if the material is not cooled properly. Composite-based t-c&bs showed significant lower curing temperatures than Trim and should therefore be preferred in daily practice. Copyright © 2010 Elsevier Ltd. All rights reserved.

  16. Economic evaluation of single-tooth replacement: dental implant versus fixed partial denture.

    Science.gov (United States)

    Kim, Younhee; Park, Joo-Yeon; Park, Sun-Young; Oh, Sung-Hee; Jung, YeaJi; Kim, Ji-Min; Yoo, Soo-Yeon; Kim, Seong-Kyun

    2014-01-01

    This study assessed the cost-effectiveness from a societal perspective of a dental implant compared with a three-unit tooth-supported fixed partial denture (FPD) for the replacement of a single tooth in 2010. A decision tree was developed to estimate cost-effectiveness over a 10-year period. The survival rates of single-tooth implants and FPDs were extracted from a meta-analysis of single-arm studies. Medical costs included initial treatment costs, maintenance costs, and costs to treat complications. Patient surveys were used to obtain the costs of the initial single-tooth implant or FPD. Maintenance costs and costs to treat complications were based on surveys of seven clinical experts at dental clinics or hospitals. Transportation costs were calculated based on the number of visits for implant or FPD treatment. Patient time costs were estimated using the number of visits and time required, hourly wage, and employment rate. Future costs were discounted by 5% to convert to present values. The results of a 10-year period model showed that a single dental implant cost US $261 (clinic) to $342 (hospital) more than an FPD and had an average survival rate that was 10.4% higher. The incremental cost-effectiveness ratio was $2,514 in a clinic and $3,290 in a hospital for a prosthesis in situ for 10 years. The sensitivity analysis showed that initial treatment costs and survival rate influenced the cost-effectiveness. If the cost of an implant were reduced to 80% of the current cost, the implant would become the dominant intervention. Although the level of evidence for effectiveness is low, and some aspects of single-tooth implants or FPDs, such as satisfaction, were not considered, this study will help patients requiring single-tooth replacement to choose the best treatment option.

  17. A comparative study to check fracture strength of provisional fixed partial dentures made of autopolymerizing polymethylmethacrylate resin reinforced with different materials: An in vitro study

    Directory of Open Access Journals (Sweden)

    Parikshit Gupt

    2017-01-01

    Conclusion: Unidirectional glass fibers showed the maximum strength, which was comparable to mean values of both stainless steel wire groups. Low cost and easy technique of using stainless steel wire make it the material of choice over the unidirectional glass fiber for reinforcement in nonesthetic areas where high strength is required.

  18. Flexural strength and hardness of resins for interim fixed partial dentures

    Directory of Open Access Journals (Sweden)

    Liju Jacob Jo

    2011-01-01

    Full Text Available Context: Materials used for the fabrication of interim restorations must satisfy biological, esthetic, and functional needs. Strength and wear resistance are two important physical properties contributing to clinical efficiency. Aim: The objective of this in vitro study was to evaluate and compare the flexural strength and hardness of five resins used for the fabrication of interim fixed partial dentures. Materials and Methods: Five groups containing ten specimens of each material were fabricated in customized brass split molds with dimensions 65×10×2.5 mm. The materials subjected to this study were Revotek LC™ (group RLC, Protemp II™ (group PSC, Acry-lux V™ with regular monomer (group AHC, Acry-lux V™ with self-cure monomer (group ASC, DPI™ self-cure tooth molding powder (group DSC. The specimens were polymerized according to the manufacturers′ instructions and were evaluated for flexural strength using a universal testing machine and for hardness using a microhardness tester. Statistical Analysis: The mean of the five groups was compared using one way analysis of variance (ANOVA and pair-wise comparison was done using Tukeys honesty significance difference (HSD test. P≤.05 was considered to be statistically significant. Results: Flexural test results showed that group AHC (79.8950 MPa had the highest flexural strength followed, in descending order, by group PSC (77.9700 MPa, group ASC (63.7150 MPa, group RLC (58.8110 MPa, and group DSC (51.9840 MPa. Statistically, the difference was found to be highly significant among all the groups. The hardness tests showed that group AHC (17.6900 KHN had the highest hardness value followed, in descending order, by group PSC (15.9400 KHN, group RLC (12.6000 KHN, group ASC (11.2500 KHN, and group DSC (8.7700 KHN. Statistically, the difference was found to be highly significant among all the groups. Conclusion: Group AHC, representing a heat-polymerizing resin, showed the highest flexural

  19. Biomechanical Outcomes of Tooth-Implant-Supported Fixed Partial Prostheses (FPPs in Periodontally Healthy Patients using Root Shape Dental Implants

    Directory of Open Access Journals (Sweden)

    Harutyunyan Argine

    2017-03-01

    Full Text Available Background: Connecting an osseointegrated implant and a natural tooth is a treatment alternative for partially edentulous patients in some clinical situations. The main issue of a connected tooth-implant system is derived from the dissimilar mobility patterns of the osseointegrated fixtures and natural abutments causing potential biomechanical problems within the entire system. Purpose: The aim of this review was to multilaterally analyze and discuss the main biomechanical factors that may question the reliability of splinted tooth-implant system and the long-term success of fixed partial prostheses (FPPs supported by both teeth and implants with an emphasis on the disparity of mobility of these two different abutments.

  20. Effect of provisional cements on shear bond strength of porcelain laminate veneers.

    Science.gov (United States)

    Altintas, Subutay Han; Tak, Onjen; Secilmis, Asli; Usumez, Aslihan

    2011-08-01

    The purpose of this study was to evaluate the effect of three provisional cements and two cleaning techniques on the final bond strength of porcelain laminate veneers. The occlusal third of the crowns of forty molar teeth were sectioned and embedded in autopolymerizing acrylic resin. Dentin surfaces were polished and specimens were randomly divided into four groups (n=10). Provisional restorations were fabricated and two provisional restorations were cemented onto each tooth. Restorations were fixed with one of three different provisional cements: eugenol-free provisional cement (Cavex), calcium hydroxide (Dycal), and light-cured provisional cement (Tempond Clear). Provisional restorations were removed with either a dental explorer and air-water spray, or a cleaning bur (Opticlean). In the control group, provisional restorations were not used on the surfaces of specimens. IPS Empress 2 ceramic discs were luted with a dual-cured resin cement (Panavia F). Shear bond strength was measured using a universal testing machine. Data were statistically analyzed by ANOVA, Tukey's HSD and Dunnett tests. Surfaces were examined by scanning electronic microscopy. Significant differences were found between the control group and both the light-cured provisional cement groups and the eugenol-free provisional cement-cleaning bur group (Pprovisional cement showed the lowest bond strength values. Selection of the provisional cement is an important factor in the ultimate bond strength of the final restoration. Calcium hydroxide provisional cement and cleaning with a dental explorer are advisable.

  1. A novel technique using arti-spot coated on fleximeter strips to determine the clearance during tooth preparation in fixed partial denture

    Directory of Open Access Journals (Sweden)

    Soma Sundaram Prasadh

    2015-01-01

    Full Text Available The amount of occlusal clearance during tooth preparation for fixed partial denture is more crucial and critical phase of fixed prosthodontics. Improper tooth reduction leads to compromise in structural durability and failure of the restoration. Over reduction affects the biological principles of tooth preparation. This article uses color coded fleximeter strips coated with arti-spot to determine the amount of clearance during tooth preparation in fixed partial denture.

  2. Gingival Retraction Methods for Fabrication of Fixed Partial Denture: Literature Review

    Directory of Open Access Journals (Sweden)

    Safari S

    2016-06-01

    Full Text Available Fixed dental prosthesis success requires appropriate impression taking of the prepared finish line. This is critical in either tooth supported fixed prosthesis (crown and bridge or implant supported fixed prosthesis (solid abutment. If the prepared finish line is adjacent to the gingival sulcus, gingival retraction techniques should be used to decrease the marginal discrepancy among the restoration and the prepared abutment. Accurate marginal positioning of the restoration in the prepared finish line of the abutment is required for therapeutic, preventive and aesthetic purposes. In this article, conventional and modern methods of gingival retraction in the fixed tooth supported prosthesis and fixed implant supported prosthesis are expressed. PubMed and Google Scholar databases were searched manually for studies on gingival tissue managements prior to impression making in fixed dental prosthesis since 1975. Conclusions were extracted and summarized. Keywords were impression making, gingival retraction, cordless retraction, and implant. Gingival retraction techniques can be classified as mechanical, chemical or surgical. In this article, different gingival management techniques are discussed.

  3. The success rate of narrow body implants used for supporting immediate provisional restorations: a pilot feasibility study.

    Science.gov (United States)

    Wang, Hom-Lay; Okayasu, Kozue; Fu, Jia-Hui; Hamerink, Howard A; Layher, Mary G; Rudek, Ivan Elimar

    2012-12-01

    Implants were first designed to be used in the reconstruction of edentulous mandibles. However, with the technological advancement, enormous changes were made to improve the implant design and surface characteristics leading to the wide use of implants in the replacement of missing teeth. During the transition from an edentulous span to a fixed prosthesis, narrow body implants (NBIs) have been proposed to enhance patient comfort and function. Therefore, this study was aimed at investigating the survival and success rates of NBIs used for supporting immediately nonfunctional loaded provisional fixed partial denture (PFPD). Either 2.2- or 2.4-mm-diameter dental implants were placed transmucosally into the edentulous ridges of 10 partially edentulous patients. PFPD of self-cured bis-acryl composite material were made using either a vacuform template chairside or a relined prefabricated PFPD. Occlusal adjustments were made to ensure that there was no functional loading on the provisional restorations before they were secured onto the transitional implants. At 1 year, the implant success and survival rates were 38.7% and 93.5%, respectively, with a mean percentage of bone loss of 9.46% (0%-40%) and a mean bone loss of 1.19 mm (range: 0-3.5 mm). With a favorable implant survival rate, the use of NBIs to support provisional restorations seemed to be a feasible treatment option. In addition, there is merit for research on the long-term use of NBIs-supported final prostheses.

  4. Fixed-point Theorem and the Nishida-Nirenberg Method in Solving Certain Nonlinear Singular Partial Differential Equations

    Directory of Open Access Journals (Sweden)

    Jose Ernie C. Lope

    2013-12-01

    Full Text Available In their 2012 work, Lope, Roque, and Tahara considered singular nonlinear partial differential equations of the form tut = F(t; x; u; ux, where the function F is assumed to be continuous in t and holomorphic in the other variables. They have shown that under some growth conditions on the coefficients of the partial Taylor expansion of F as t 0, the equation has a unique solution u(t; x with the same growth order as that of F(t; x; 0; 0. Koike considered systems of partial differential equations using the Banach fixed point theorem and the iterative method of Nishida and Nirenberg. In this paper, we prove the result obtained by Lope and others using the method of Koike, thereby avoiding the repetitive step of differentiating a recursive equation with respect to x as was done by the aforementioned authors.

  5. Structure and mechanical properties of Cresco-Ti laser-welded joints and stress analyses using finite element models of fixed distal extension and fixed partial prosthetic designs.

    Science.gov (United States)

    Uysal, Hakan; Kurtoglu, Cem; Gurbuz, Riza; Tutuncu, Naki

    2005-03-01

    The Cresco-Ti System uses a laser-welded process that provides an efficient technique to achieve passive fit frameworks. However, mechanical behavior of the laser-welded joint under biomechanical stress factors has not been demonstrated. This study describes the effect of Cresco-Ti laser-welding conditions on the material properties of the welded specimen and analyzes stresses on the weld joint through 3-dimensional finite element models (3-D FEM) of implant-supported fixed dentures with cantilever extensions and fixed partial denture designs. Twenty Grade III (ASTM B348) commercially pure titanium specimens were machine-milled to the dimensions described in the EN10002-1 tensile test standard and divided into test (n = 10) and control (n = 10) groups. The test specimens were sectioned and laser-welded. All specimens were subjected to tensile testing to determine yield strength (YS), ultimate tensile strength (UTS), and percent elongation (PE). The Knoop micro-indentation test was performed to determine the hardness of all specimens. On welded specimens, the hardness test was performed at the welded surface. Data were analyzed with the Mann-Whitney U test and Student's t test (alpha=.05). Fracture surfaces were examined by scanning electron microscopy to characterize the mode of fracture and identify defects due to welding. Three-dimensional FEMs were created that simulated a fixed denture with cantilever extensions supported by 5 implants (M1) and a fixed partial denture supported by 2 implants (M2), 1 of which was angled 30 degrees mesio-axially. An oblique load of 400 N with 15 degrees lingual-axial inclinations was applied to both models at various locations. Test specimens fractured between the weld and the parent material. No porosities were observed on the fractured surfaces. Mean values for YS, UTS, PE, and Knoop hardness were 428 +/- 88 MPa, 574 +/- 113 MPa, 11.2 +/- 0.4%, 270 +/- 17 KHN, respectively, for the control group and 642 +/- 2 MPa, 772 +/- 72

  6. Fixed point results for generalized Chatterjea type contractive conditions in partially ordered G-metric spaces.

    Science.gov (United States)

    Khan, Safeer Hussain; Abbas, Mujahid; Nazir, Talat

    2014-01-01

    In the framework of ordered G-metric spaces, fixed points of maps that satisfy the generalized (ψ, φ)-Chatterjea type contractive conditions are obtained. The results presented in the paper generalize and extend several well known comparable results in the literature.

  7. Identification of risk factors for fracture of veneering materials and screw loosening of implant-supported fixed partial dentures in partially edentulous cases.

    Science.gov (United States)

    Noda, K; Arakawa, H; Maekawa, K; Hara, E S; Yamazaki, S; Kimura-Ono, A; Sonoyama, W; Minakuchi, H; Matsuka, Y; Kuboki, T

    2013-03-01

    This retrospective study identified the risk factors for fracture of veneering materials and screw loosening of implant-supported fixed partial dentures in partially edentulous cases. The study group included a total of 182 patients who were installed 219 suprastructures at the Fixed Prosthodontic Clinic of Okayama University Dental Hospital between February 1990 and March 2005 and were subdivided in two subgroups: 120 patients (149 facing suprastructures) were included in the subgroup to investigate the risk factors of fracture of veneering materials, and 81 patients (92 suprastructures) were included in the subgroup to identify the risk factors of abutment screw loosening. Each patient was followed up from the day of suprastructure installation until March, 2005. A Cox proportional hazards regression model was used to identify the risk factors related to technical complications, and eight factors were regarded as candidate risk factors. Screw retention was the significant risk factor for fracture of veneering materials, whereas connection of suprastructures with natural tooth was the significant risk factor for screw loosening. It was suggested that screw retention was a significant risk factor for the fracture of veneering materials, and connection of suprastructures with natural tooth was a significant risk factor for screw loosening. Future studies, involving dynamic factors (e.g. bruxism) as predictors as well, are more helpful to discuss the risk factor of fracture of veneering materials and screw loosening. © 2013 Blackwell Publishing Ltd.

  8. Evaluation of fracture resistance of inlay-retained fixed partial dentures fabricated with different monolithic zirconia materials.

    Science.gov (United States)

    Gumus, Hilal Siriner; Polat, Nilufer Tulin; Yildirim, Guler

    2017-09-29

    Data are lacking on the fracture resistance of monolithic zirconia inlay-retained fixed partial dentures as a conservative treatment for a single missing tooth. The purpose of this in vitro study was to evaluate the fracture resistance of inlay-retained fixed partial dentures produced from 3 different monolithic zirconia materials and based on 2 preparation types and applications with and without thermocycling. A model with missing right and left mandibular first molars was used for different cavity preparations. A tube-shaped cavity and a box-shaped cavity were prepared. Seventy-two epoxy resin casts were prepared from an additional silicone impression. Twenty-four inlay-retained fixed partial dentures from each monolithic zirconia material (Prettau, Zirkonzahn; Katana, Noritake; and Copran, Whitepeaks) were fabricated for each preparation type and cemented to their epoxy model with dual-polymerizing adhesive resin cement; 50% of all specimens were thermocycled for 10000 cycles. The specimens were subjected to a fracture resistance test using a universal testing machine with a crosshead speed of 0.5 mm/min. Fracture surfaces were examined with scanning electron microscopy (SEM), and a specimen from each group was examined for structural changes with differential thermal analysis (DTA). No statistically significant differences in terms of fracture resistance were found among brands with both cavity designs and with and without thermal cycles (P>.05). However, SEM and DTA results showed some changes in monolithic zirconia structure after 1 year of aging. The brands and cavity preparation types for single posterior tooth loss generated similar fracture resistance. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  9. OCT and shear-force evaluations of zirconia Fixed Partial Prosthesis processed with a conventional CAD/CAM technology

    Science.gov (United States)

    Zaharia, C.; Gabor, A.; Sinescu, C.; Topala, F. I.; Negrutiu, M. L.; Levai, C. M.; Duma, V. F.; Bradu, A.; Podoleanu, A. Gh.

    2016-03-01

    Introduction. Dental ceramics show better biocompatibility and aesthetic properties in dental constructs with regard to metals. However, they also have an insufficient mechanical stability, as well as low resistance limits due to their fragility. Taking into account these aspects, glass infiltrated with ceramic materials such as alumina (i.e., zirconiareinforced ceramics) is being nowadays considered a better material for full fixed partial prostheses (FPPs) than ceramics: the former has a higher mechanical resistance, which makes it more appropriate for restoration areas, where there is an increased mechanical stress. The interest for zirconia is growing due both to its resistance and to the possibility to develop such prostheses using the CAD/CAM technology. Materials and methods. 24 all ceramic FPPs created with CAD/CAM technology were used. The models were scanned with Zeno Wieland Scanner, a one touch scanning machine which requires between 45-60 s for a full model scan. The scanner provides 3 axis-architecture and automatic data processing. The zirconia infrastructures resulted from milling zirconia green disks in Wieland units, followed by the deposition of ceramic masses and then by burning procedures. All the samples were assessed with a Time Domain Optical Coherence Tomography (TD-OCT) system working at a wavelenght of 1300 nm. Using OCT investigations, material defects were detected in the areas of maximal tension, i.e. the connectors, the oclusal, and the cervical areas. These samples with defects in the above areas have not been considered for the study further on. Finally, the samples were loaded in a MultiTest 5 i Mecmesin system and tested until fracture occurred. The MultiTest 5-i creates tensile and compression forces of up to 5 kN. Results and discussions. All the test samples survived a dynamic load of 1.2 x 107 cycles and a thermal cycle mixer simulator version; signs of failure in terms of fracture lines were observed in all samples. The

  10. Comparative Evaluation of Marginal Accuracy of a Cast Fixed Partial Denture Compared to Soldered Fixed Partial Denture Made of Two Different Base Metal Alloys and Casting Techniques: An In vitro Study.

    Science.gov (United States)

    Jei, J Brintha; Mohan, Jayashree

    2014-03-01

    The periodontal health of abutment teeth and the durability of fixed partial denture depends on the marginal adaptation of the prosthesis. Any discrepancy in the marginal area leads to dissolution of luting agent and plaque accumulation. This study was done with the aim of evaluating the accuracy of marginal fit of four unit crown and bridge made up of Ni-Cr and Cr-Co alloys under induction and centrifugal casting. They were compared to cast fixed partial denture (FPD) and soldered FPD. For the purpose of this study a metal model was fabricated. A total of 40 samples (4-unit crown and bridge) were prepared in which 20 Cr-Co samples and 20 Ni-Cr samples were fabricated. Within these 20 samples of each group 10 samples were prepared by induction casting technique and other 10 samples with centrifugal casting technique. The cast FPD samples obtained were seated on the model and the samples were then measured with travelling microscope having precision of 0.001 cm. Sectioning of samples was done between the two pontics and measurements were made, then the soldering was made with torch soldering unit. The marginal discrepancy of soldered samples was measured and all findings were statistically analysed. The results revealed minimal marginal discrepancy with Cr-Co samples when compared to Ni-Cr samples done under induction casting technique. When compared to cast FPD samples, the soldered group showed reduced marginal discrepancy.

  11. Energy-Efficient Power Allocation for Fixed-Gain Amplify-and-Forward Relay Networks with Partial Channel State Information

    KAUST Repository

    Zafar, Ammar

    2012-09-16

    In this letter, energy-efficient transmission and power allocation for fixed-gain amplify-and-forward relay networks with partial channel state information (CSI) are studied. In the energy-efficiency problem, the total power consumed is minimized while keeping the signal-to-noise-ratio (SNR) above a certain threshold. In the dual problem of power allocation, the end-to-end SNR is maximized under individual and global power constraints. Closed-form expressions for the optimal source and relay powers and the Lagrangian multiplier are obtained. Numerical results show that the optimal power allocation with partial CSI provides comparable performance as optimal power allocation with full CSI at low SNR. © 2012 IEEE.

  12. Energy-Efficient Power Allocation for Fixed-Gain Amplify-and-Forward Relay Networks with Partial Channel State Information

    KAUST Repository

    Zafar, Ammar

    2012-06-01

    In this report, energy-efficient transmission and power allocation for fixed-gain amplify-and-forward relay networks with partial channel state information (CSI) are studied. In the energy-efficiency problem, the total power consumed is minimized while keeping the signal-to-noise-ratio (SNR) above a certain threshold. In the dual problem of power allocation, the end-to-end SNR is maximized under individual and global power constraints. Closed-form expressions for the optimal source and relay powers and the Lagrangian multiplier are obtained. Numerical results show that the optimal power allocation with partial CSI provides comparable performance as optimal power allocation with full CSI at low SNR.

  13. Complete and partial contour zirconia designs for crowns and fixed dental prostheses: a clinical report.

    Science.gov (United States)

    Marchack, Baldwin W; Sato, Shoko; Marchack, Christopher B; White, Shane N

    2011-09-01

    Since the introduction of milled zirconia copings for ceramic crowns, a variety of techniques have been introduced to reduce the incidence of chipping or fracturing of the porcelain veneer. These include methods of improving the interface between the coping and the veneer, reducing thermal incompatibility between the two, and optimizing the coping design to minimize tensile loading on the porcelain. Another method of reducing porcelain chipping and fracture is to limit or eliminate the porcelain coverage of zirconia copings and frameworks. Even though patients often demand tooth colored or nonmetallic restorations, they tend to be less concerned with the optimal esthetics of their posterior teeth. This article describes 4 representative clinical situations where efforts were made to minimize or eliminate porcelain coverage on posterior zirconia crowns and a fixed dental prosthesis, while still achieving acceptable, but not optimal, esthetics. Copyright © 2011 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  14. Dairy Biomass-Wyoming Coal Blends Fixed Gasification Using Air-Steam for Partial Oxidation

    Directory of Open Access Journals (Sweden)

    Gerardo Gordillo

    2012-01-01

    Full Text Available Concentrated animal feeding operations such as dairies produce a large amount of manure, termed as dairy biomass (DB, which could serve as renewable feedstock for thermal gasification. DB is a low-quality fuel compared to fossil fuels, and hence the product gases have lower heat content; however, the quality of gases can be improved by blending with coals. This paper deals with air-steam fixed-bed counterflow gasification of dairy biomass-Wyoming coal blend (DBWC. The effects of equivalence ratio (1.6<Φ<6.4 and steam-to-fuel ratio (0.4

  15. Effect of Provisional Cements on Shear Bond Strength of Porcelain Laminate Veneers

    Science.gov (United States)

    Altintas, Subutay Han; Tak, Onjen; Secilmis, Asli; Usumez, Aslihan

    2011-01-01

    Objectives: The purpose of this study was to evaluate the effect of three provisional cements and two cleaning techniques on the final bond strength of porcelain laminate veneers. Methods: The occlusal third of the crowns of forty molar teeth were sectioned and embedded in autopolymerizing acrylic resin. Dentin surfaces were polished and specimens were randomly divided into four groups (n=10). Provisional restorations were fabricated and two provisional restorations were cemented onto each tooth. Restorations were fixed with one of three different provisional cements: eugenol-free provisional cement (Cavex), calcium hydroxide (Dycal), and light-cured provisional cement (Tempond Clear). Provisional restorations were removed with either a dental explorer and air-water spray, or a cleaning bur (Opticlean). In the control group, provisional restorations were not used on the surfaces of specimens. IPS Empress 2 ceramic discs were luted with a dual-cured resin cement (Panavia F). Shear bond strength was measured using a universal testing machine. Data were statistically analyzed by ANOVA, Tukey’s HSD and Dunnett tests. Surfaces were examined by scanning electronic microscopy. Results: Significant differences were found between the control group and both the light-cured provisional cement groups and the eugenol-free provisional cement-cleaning bur group (P<.05). Groups that had received light-cured provisional cement showed the lowest bond strength values. Conclusions: Selection of the provisional cement is an important factor in the ultimate bond strength of the final restoration. Calcium hydroxide provisional cement and cleaning with a dental explorer are advisable. PMID:21912495

  16. Effect of nightguard vital bleaching gel on the color stability of provisional restorative materials

    OpenAIRE

    Salwa Omar Bajunaid

    2016-01-01

    Purpose: To assess the hypothesis that there was no difference in effect of 10% and 15% tooth bleaching agents on color stability of materials used for provisional fixed dental prosthesis. Methodology: Fifteen samples from two materials used for provisional fixed dental prosthesis: methacrylate-based and composite-based materials and 15 preformed polycarbonate crowns soaked in bleaching gel or distilled water. Spectrophotometer recorded color of specimens at baseline, after 3, 7, and 14 d...

  17. Current bonding systems for resin-bonded restorations and fixed partial dentures made of silver–palladium–copper–gold alloy

    Directory of Open Access Journals (Sweden)

    Hideo Matsumura

    2011-02-01

    Full Text Available This review article describes about the bonding systems for noble metal alloys, bonding techniques of restorations and fixed partial dentures (FPDs made of Ag–Pd–Cu–Au alloys, and their clinical performance. Thione monomers, 6-(4-vinylbenzyl-n-propyl amino-1,3,5-triazine-2,4-dithione (VTD, 6-methacryloyloxyhexyl-2-thiouracil-5-carboxylate (MTU-6, and 10-methacryloxydecyl 6,8-dithiooctanoate (MDDT, has been proved effective for bonding noble metal alloys. An acrylic adhesive consists of the tri-n-butylborane (TBB initiator, methyl methacrylate (MMA monomer liquid with 5% 4-methacryloyloxyethyl trimellitate anhydride (4-META, and poly(methyl methacrylate (PMMA, is being used for bonding metallic restorations to abutment surfaces. Clinical performance of restorations and FPDs made of Ag–Pd–Cu–Au alloys is overall excellent when they are seated with the currently available noble metal bonding systems.

  18. Occlusion for implant-supported fixed dental prostheses in partially edentulous patients: a literature review and current concepts.

    Science.gov (United States)

    Yuan, Judy Chia-Chun; Sukotjo, Cortino

    2013-04-01

    Implant treatment has become the treatment of choice to replace missing teeth in partially edentulous areas. Dental implants present different biological and biomechanical characteristics than natural teeth. Occlusion is considered to be one of the most important factors contributing to implant success. Most literature on implant occlusal concepts is based on expert opinion, anecdotal experiences, in vitro and animal studies, and only limited clinical research. Furthermore, scientific literature regarding implant occlusion, particularly in implant-supported fixed dental prostheses remains controversial. In this study, the current status of implant occlusion was reviewed and discussed. Further randomized clinical research to investigate the correlation between implant occlusion, the implant success rate, and its risk factors is warranted to determine best clinical practices.

  19. Fracture Resistance of Composite Fixed Partial Dentures Reinforced with Pre-impregnated and Non-impregnated Fibers

    Directory of Open Access Journals (Sweden)

    Ramin Mosharraf

    2012-02-01

    Full Text Available Background and aims. The mechanical properties of fiber-reinforced composite fixed partial dentures (FPDs are affected by fiber impregnation. The aim of this in vitro study was to compare the fracture resistance of composite fixed partial dentures reinforced with pre-impregnated and non-impregnated fibers. Materials and methods. Groups (n=5 of three-unit fiber-reinforced composite FPDs (23 mm in length from maxillary second premolar to maxillary second molar were fabricated on two abutments with pontic width of 12 mm. One group was fabricated as the control group with composite (Gradia and the other two groups were fabricated with composite (Gradia reinforced with pre-impregnated fiber (Fibrex ribbon and non-impregnated fiber (Fiber braid, respectively. The specimens were stored in distilled water for one week at 37°C and then tested in a universal testing machine by means of a three-point bending test. Statistical analysis consisted of one-way ANOVA and a post hoc Scheffé’s test for the test groups (α=0.05. Results. Fracture resistance (N differed significantly between the control group and the other two groups (P<0.001, but there were no statistically significant differences between the pre-impregnated and non-impregnated groups (P=0.565. The degree of deflection measured (mm did not differ significantly between the three groups (P=0.397, yet the mean deflection measured in pre-impregnated group was twice as that in the other two groups. Conclusion. Reinforcement of composite with fiber might considerably increase the fracture resistance of FPDs; however, the type of the fiber used resulted in no significant difference in fracture resistance of FPD specimens.

  20. The use of transitional implants to support provisional prostheses during the healing phase: a literature review.

    Science.gov (United States)

    de Almeida, Erika Oliveira; Filho, Homberto Gennari; Goiatto, Marcelo Coelho

    2011-01-01

    transitional implants are indicated for cases in which immediate loading is counterindicated because a healing period is necessary for osseointegration of the definitive implants. These provisional implants were developed to support an implant-supported fixed prosthesis or overdenture to provide retention, stability, and support. The aim of this article was to conduct a literature review on transitional implants to highlight the characteristics of the transitional implants and their advantages, indications, and contraindications, including the level of osseointegration of such implants according to the functional period. the present literature review was based on the Old Medline and Medline databases from 1999 to 2010 using the key words "transitional implants" and "temporary implants." Fourteen articles were found: 11 clinical studies or techniques and three histologic and histomorphometric studies. the transitional immediate prostheses were worn by completely and partially edentulous patients. Advantages of transitional implants include complete denture retention, stability, and support; maintenance of chewing, phonetics, and patient comfort; protection of bone grafts; vertical stop during healing period; easy and fast surgical and prosthetic procedures; lower cost in comparison to the definitive implant; and reestablishment of esthetics. The success of transitional implants as conservative treatment for conventional immediate loading is a reality if correctly indicated. transitional implants are a provisional treatment alternative for completely and partially edentulous patients. However, additional studies are required to evaluate the level of remodeling and repair of the transitional implants under loading.

  1. Immediate non-occlusal loading vs. early loading in partially edentulous patients.

    Science.gov (United States)

    Testori, Tiziano; Bianchi, Francesca; Del Fabbro, Massimo; Szmukler-Moncler, Serge; Francetti, Luca; Weinstein, Roberto Ludovico

    2003-01-01

    Immediate loading of dental implants can reduce treatment time and management concerns, thus increasing patient acceptance. This paper reports the authors' preliminary experience with partially edentulous patients having received non-occlusally loaded provisional restorations within 24 hours of surgery, compared to patients treated according to an early loading protocol. The present data suggest that implant supported fixed partial prostheses can be immediately non-occlusally loaded and restored with a predictability similar to early loaded implants.

  2. Three-dimensional finite element analysis of zirconia all-ceramic cantilevered fixed partial dentures with different framework designs.

    Science.gov (United States)

    Miura, Shoko; Kasahara, Shin; Yamauchi, Shinobu; Egusa, Hiroshi

    2017-06-01

    The purpose of this study were: to perform stress analyses using three-dimensional finite element analysis methods; to analyze the mechanical stress of different framework designs; and to investigate framework designs that will provide for the long-term stability of both cantilevered fixed partial dentures (FPDs) and abutment teeth. An analysis model was prepared for three units of cantilevered FPDs that assume a missing mandibular first molar. Four types of framework design (Design 1, basic type; Design 2, framework width expanded buccolingually by 2 mm; Design 3, framework height expanded by 0.5 mm to the occlusal surface side from the end abutment to the connector area; and Design 4, a combination of Designs 2 and 3) were created. Two types of framework material (yttrium-oxide partially stabilized zirconia and a high precious noble metal gold alloy) and two types of abutment material (dentin and brass) were used. In the framework designs, Design 1 exhibited the highest maximum principal stress value for both zirconia and gold alloy. In the abutment tooth, Design 3 exhibited the highest maximum principal stress value for all abutment teeth. In the present study, Design 4 (the design with expanded framework height and framework width) could contribute to preventing the concentration of stress and protecting abutment teeth. © 2017 Eur J Oral Sci.

  3. Retrospective comparative ten-year study of cumulative survival rates of remaining teeth in large edentulism treated with implant-supported fixed partial dentures or removable partial dentures.

    Science.gov (United States)

    Yamazaki, Seiya; Arakawa, Hikaru; Maekawa, Kenji; Hara, Emilio Satoshi; Noda, Kinji; Minakuchi, Hajime; Sonoyama, Wataru; Matsuka, Yoshizo; Kuboki, Takuo

    2013-07-01

    This study aimed to compare the survival rates of remaining teeth between implant-supported fixed dentures (IFDs) and removable partial dentures (RPDs) in patients with large edentulous cases. The second goal was to assess the risk factors for remaining tooth loss. The study subjects were selected among those who received prosthodontic treatment at Okayama University Dental Hospital for their edentulous space exceeding at least four continuous missing teeth. Twenty-one patients were included in the IFD group and 82 patients were included in the RPD group. Survival rates of remaining teeth were calculated in three subcategories: (1) whole remaining teeth, (2) adjacent teeth to intended edentulous space, and (3) opposing teeth to intended edentulous space. The ten-year cumulative survival rate of the whole remaining teeth was significantly higher in the IFD group (40.0%) than in the RPD group (24.4%). On the other hand, there was no significant difference between two groups in the survival rate of teeth adjacent or opposing to intended edentulous space. A Cox proportional hazard analysis revealed that RPD restoration and gender (male) were the significant risk factors for remaining tooth loss (whole remaining teeth). These results suggest that IFD treatment can reduce the incidence of remaining tooth loss in large edentulous cases. Copyright © 2013 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  4. Oral health-related quality of life in patients treated by implant-supported fixed dentures and removable partial dentures.

    Science.gov (United States)

    Furuyama, Chisako; Takaba, Masayuki; Inukai, Mika; Mulligan, Roseann; Igarashi, Yoshimasa; Baba, Kazuyoshi

    2012-08-01

    This study investigated the association between denture status [implant-supported fixed dentures (IDs) and removable partial dentures (RPDs)] and oral health-related quality of life (OHRQoL). Consecutive patients with IDs and RPDs were recruited from the Prosthodontics Departments at Showa University and Tokyo Medical and Dental University. The Japanese version of the Oral Health Impact Profile (OHIP-J-49) was administered to each subject. For each OHIP-J-49 question, the subjects were asked to indicate the frequency with which they had experienced a dental problem during the last month. Responses were recorded on a 5 point Likert rating scale, with 0 being never and 4, very often. Summary scores were calculated and regression analyses conducted to investigate the association between denture status and OHIP-J-49 summary score. In total 79 ID subjects (mean age±SD of 51.7±12.4 years, 44.3% men) and 109 RPD subjects (mean age of 66.5±8.6 years, 30% men) participated after giving informed consent. The regression analysis between the type of treatment and the OHIP-J-49 summary score revealed a significant association with a coefficient of 17.0 (Confidence interval, CI: 10.9-23.1). When age and duration of denture usage, which had significant associations with OHIP-J-49, were included in this model, the regression coefficient remained virtually unchanged at 17.4 (CI: 9.75-25.0), thus indicating little potential confounding by them. OHRQoL in patients with implant-supported fixed dentures is generally less impaired than it is in those patients with RPDs. © 2011 John Wiley & Sons A/S.

  5. Marginal adaptation of inlay-retained adhesive fixed partial dentures after mechanical and thermal stress: an in vitro study.

    Science.gov (United States)

    Göehring, T N; Peters, O A; Lutz, F

    2001-07-01

    There are no studies that analyze the long-term durability of minimally invasive fixed partial dentures (FPDs) by comparing different methods of adhesive bonding. This in vitro study examined the influence of cavity design and operative technique on the marginal adaptation of resin-bonded composite FPDs. Slot-inlay tooth preparations with cavity margins located in enamel were prepared in 18 maxillary canines and 18 maxillary first molars designated as abutments. The specimens were divided equally into 3 experimental groups. In all groups, butt joint tooth preparations were created in canines and molars. In group 2, canines were prepared additionally with a 1.5-mm wide palatal bevel in enamel. After pretests with modification spaces of 11 and 17 mm (length), 2 missing premolars were replaced by the ceromer Targis and reinforced with the glass-fiber material Vectris. The prostheses were inserted with Tetric Ceram with use of an ultrasonic-supported, high-viscosity technique. Restorations were selectively bonded to cavity finish lines in groups 1 and 2 ("selective bonding"). In group 3, restorations were bonded totally to the whole cavity surface ("total bonding"). The restorations were stressed in a computer-controlled masticator. Marginal quality was examined with an SEM at x 200. The percent area of optimal margins after thermomechanical loading between composite and enamel in each group was as follows: group 1, 86.2% +/- 12.3% for canines and 95.5% +/- 3.5% for molars; group 2, 95.3% +/- 2.1% for canines and 96.2% +/- 2.7% for molars; and group 3, 95% +/- 0.9% for canines and 86.4% +/- 3.2% for molars. The marginal quality for molars inserted with total bonding was significantly lower (P< or =.05). Within the limitations of this study, the selective bonding technique for slot inlay-retained fixed partial dentures resulted in a negligible loss of marginal quality after extensive mechanical and thermal stress. The selective bonding technique is recommended for box

  6. Adiabatic Fixed-Bed Gasification of Colombian Coffee Husk Using Air-Steam Blends for Partial Oxidation

    Directory of Open Access Journals (Sweden)

    Javier Bonilla

    2017-01-01

    Full Text Available The increasing energy consumption, mostly supplied by fossil fuels, has motivated the research and development of alternative fuel technologies to decrease the humanity’s dependence on fossil fuels, which leads to pollution of natural sources. Small-scale biomass gasification, using air-steam blends for partial oxidation, is a good alternative since biomass is a neutral carbon feedstock for sustainable energy generation. This research presents results obtained from an experimental study on coffee husk (CH gasification, using air-steam blends for partial oxidation in a 10 kW fixed-bed gasifier. Parametric studies on equivalence ratio (ER (1.53 < ER < 6.11 and steam-fuel (SF ratio (0.23 < SF < 0.89 were carried out. The results show that increasing both SF and ER results in a syngas rich in CH4 and H2 but poor in CO. Also, decreased SF and ER decrease the peak temperature (Tpeak at the gasifier combustion zone. The syngas high heating value (HHV ranged from 3112 kJ/SATPm3 to 5085 kJ/SATPm3 and its maximum value was obtained at SF = 0.87 and ER = 4.09. The dry basis molar concentrations of the species, produced under those operating conditions (1.53 < ER < 6.11 and 0.23 < SF < 0.89, were between 1.12 and 4.1% for CH4, between 7.77 and 13.49% for CO, and between 7.54 and 19.07% for H2. Other species were in trace amount.

  7. Five-year survival of 3-unit fiber-reinforced composite fixed partial dentures in the posterior area.

    Science.gov (United States)

    van Heumen, Céleste C M; Tanner, Johanna; van Dijken, Jan W V; Pikaar, Ronald; Lassila, Lippo V J; Creugers, Nico H J; Vallittu, Pekka K; Kreulen, Cees M

    2010-10-01

    The purpose of this clinical study was to evaluate the long-term outcome of three-unit posterior fixed partial dentures (FPDs) made of fiber-reinforced resin composite (FRC), and to identify design factors influencing the survival rate. 77 patients (52 females, 25 males) received 96 indirectly made FRC FPDs, using pre-impregnated unidirectional glass-fibers, requiring manual wetting, as framework material. FPDs were surface (n=31) inlay (n=45) or hybrid (n=20) retained and mainly located in the upper jaw. Hybrid FPDs consisted of a wing retainer at canine and an inlay retainer at distal abutment tooth. Surface FPDs consisted of uplay and wing combinations. Follow-up period was at minimum 4.5 years, with checkups at every 1-2 years. The study was carried out by six operators in three centers in the Netherlands, Finland and Sweden. Survival rates, including reparable defects of FPDs, and success rates were determined. Kaplan-Meier survival rate at 5 years was 71.2% (SE 4.8%) for success and 77.5% (SE 4.4%) for survival. Differences were not significantly different. Main failure modes were delamination and fracture of the FPD. Only FPDs with surface retainers showed debonding. A success rate of 71% and a survival rate of 78% after 5 years was found. Survival rates of inlay, hybrid and surface retained FPDs did not significantly differ. Copyright 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  8. Evaluation of stress patterns produced by implant-retained overdentures and implant-retained fixed partial denture.

    Science.gov (United States)

    Mazaro, José Vitor Quinelli; Filho, Humberto Gennari; Vedovatto, Eduardo; Pellizzer, Eduardo Piza; Rezende, Maria Cristina Rosifini Alves; Zavanelli, Adriana Cristina

    2011-11-01

    The purposes of this study were to photoelastically measure the biomechanical behavior of 4 implants retaining different cantilevered bar mandibular overdenture designs and to compare a fixed partial denture (FPD). A photoelastic model of a human edentulous mandible was fabricated, which contained 4 screw-type implants (3.75 × 10 mm) embedded in the parasymphyseal area. An FPD and 3 overdenture designs with the following attachments were evaluated: 3 plastic Hader clips, 1 Hader clip with 2 posterior resilient cap attachments, and 3 ball/O-ring attachments. Vertical occlusal forces of 100 N were applied between the central incisor and unilaterally to the right and left second premolars and second molars. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. The results showed that the anterior loading, the overdenture with 3 plastic Hader clips, displayed the largest stress concentration at the medium implant. With premolar loading, the FPD and overdenture with 3 plastic Hader clips displayed the highest stresses to the ipsilateral terminal implant. With molar loading, the overdenture with 3 ball/O-ring attachments displayed the most uniform stress distribution in the posterior edentulous ridge, with less overloading in the terminal implant. It was concluded that vertical forces applied to the bar-clip overdenture and FPD created immediate stress patterns of greater magnitude and concentration on the ipsilateral implants, whereas the ball/O-ring attachments transferred minimal stress to the implants. The increased cantilever in the FPD caused the highest stresses to the terminal implant.

  9. Clinical outcome of tooth-supported fixed partial dentures in unilateral cleft lip and palate patients: A case series

    Directory of Open Access Journals (Sweden)

    Sudhir Bhandari

    2017-01-01

    Discussion: CLP patients undergo a lot of treatment; therefore understanding their opinions, expectations, and perspectives towards the prosthodontic intervention was given due importance. The provisional phase was utilized to educate the patients on the achievable treatment outcome and its limitation. In the present case series, out of three failed FPDs, only one restoration failed relatively early due to functional factors. Re-treatment was successfully achieved without change in the original material and extent of the FPDs. Conclusion: The outcome accomplished endorses the integral role of T-FPDs in the overall cleft care and it will remain a viable treatment alternative in select few patients in meeting their esthetic and functional desires.

  10. Fracture strength of direct surface-retained fixed partial dentures : Effect of fiber reinforcement versus the use of particulate filler composites only

    NARCIS (Netherlands)

    Kumbuloglu, Ovul; Ozcan, Mutlu; User, Atilla

    This study compared the fracture strengths and analyzed the failure types of direct, surface-retained, anterior fixed-partial-dentures (FPD), reinforced with four types of fiber-reinforced composites (FRC) versus non-fiber-reinforced FPDs made of three particulate filler composites (PFC). To this

  11. Five-year survival of 3-unit fiber-reinforced composite fixed partial dentures in the anterior area.

    Science.gov (United States)

    van Heumen, Céleste C M; van Dijken, Jan W V; Tanner, Johanna; Pikaar, Ronald; Lassila, Lippo V J; Creugers, Nico H J; Vallittu, Pekka K; Kreulen, Cees M

    2009-06-01

    The purpose of this clinical study was to evaluate the long-term outcome of 3-unit anterior fixed partial dentures (FPDs) made of fiber-reinforced resin composite (FRC), and to identify design factors influencing the survival rate. 52 patients (26 females, 26 males) received 60 indirectly made FRC FPDs, using pre-impregnated unidirectional glass fibers, requiring manual wetting, as framework material. FPDs were surface (n=48) or hybrid (n=12) retained and mainly located in the upper jaw. Hybrid FPDs had a combination of retainers; i.e. crown at one and surface retention at the other abutment tooth. Surface FPDs were either purely adhesively retained (n=29) or with additional mechanical retention (n=19). Follow-up period was at minimum 5 years, with check-ups every 1-2 years. Six operators were involved, in three centers in the Netherlands, Finland and Sweden. Survival rates, including repairable defects of FPDs, and success rates were determined. Kaplan-Meier survival rate at 5 years was 64% (SE 7%). For the level of success, values were 45% (SE 7%) and the estimated median survival time 58 (SE 10.1) months. For surface FPDs, additional mechanical retention did not improve survival significantly. There was a trend towards better survival of surface FPDs over hybrid FPDs, but differences were not significant. Main failure modes were fracture of the FPD and delamination of veneering composite. A success rate of 45% and a survival rate of 64% after 5 years was found. Fracture of the framework and delamination are the most prevalent failure modes, especially for surface FPDs.

  12. Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study.

    Science.gov (United States)

    Tinschert, J; Natt, G; Mautsch, W; Augthun, M; Spiekermann, H

    2001-01-01

    The purpose of this study was to determine the fracture resistance of three-unit fixed partial dentures (FPD) made of new core ceramics. A base metal three-unit master FPD model with a maxillary premolar and molar abutment was made. Tooth preparation showed 0.8-mm circumferential and 1.5-mm occlusal reduction and a chamfer margin design. FPDs were constructed with a uniform 0.8-mm-thick core ceramic and a porcelain veneer layer. In-Ceram Alumina, In-Ceram Zirconia, and DC-Zirkon core ceramics were machined by a computer-aided design/manufacturing system, whereas IPS Empress 2 core ceramic was indirectly built up using the fabrication technology of waxing and heat pressing. FPDs of IPS Empress were heat pressed as complete restorations without core material. To ensure standardized dimensions, the FPDs were controlled at different points. All FPDs were cemented with ZnPO4 on the master model and loaded on a universal testing machine until failure. The failure load and mode of failure were recorded. The highest failure loads, exceeding 2,000 N, were associated with FPDs of DC-Zirkon. FPDs of IPS Empress and In-Ceram Alumina showed the lowest failure loads, below 1,000 N, whereas intermediate values were observed for FPDs of IPS Empress 2 and In-Ceram Zirconia. Differences in mean values were statistically significant. The high fracture resistance evaluated for FPDs made of DC-Zirkon underscores the remarkable mechanical properties of high-performance ceramic, which could be useful for highly loaded all-ceramic restorations, especially in the molar region.

  13. Biomechanical comparison of two different collar structured implants supporting 3-unit fixed partial denture: a 3-D FEM study.

    Science.gov (United States)

    Meriç, Gökçe; Erkmen, Erkan; Kurt, Ahmet; Eser, Atilim; Ozden, Ahmet Utku

    2012-01-01

    The purpose of the study was to compare the effects of two distinct collar geometries of implants on stress distribution in the bone as well as in the fixture-abutment complex, in the framework and in the veneering material of 3-unit fixed partial denture (FPD). The 3-dimensional finite element analysis method was selected to evaluate the stress distribution in the system composed of 3-unit FPD supported by two different dental implant systems with two distinct collar geometries; microthread collar structure (MCS) and non-microthread collar structure (NMCS). In separate load cases, 300 N vertical, 150 N oblique and 60 N horizontal, forces were utilized to simulate the multidirectional chewing forces. Tensile and compressive stress values in the cortical and cancellous bone and von Mises stresses in the fixture-abutment complex, in the framework and veneering material, were simulated as a body and investigated separately. In the cortical bone lower stress values were found in the MCS model, when compared with NMCS. In the cancellous bone, lower stress values were observed in the NMCS model when compared with MCS. In the implant-abutment complex, highest von Mises stress values were noted in the NMCS model; however, in the framework and veneering material, highest stress values were calculated in MCS model. MCS implants when compared with NMCS implants supporting 3-unit FPDs decrease the stress values in the cortical bone and implant-abutment complex. The results of the present study will be evaluated as a base for our ongoing FEA studies focused on stress distribution around the microthread and non-microthread collar geometries with various prosthesis design.

  14. Effect of framework design on fracture resistance in zirconia 4-unit all-ceramic fixed partial dentures.

    Science.gov (United States)

    Takuma, Yusuke; Nomoto, Syuntaro; Sato, Toru; Sugihara, Naoki

    2013-01-01

    The purpose of this study was to conduct static load-bearing tests on 4-unit Y-TZP all-ceramic fixed partial denture (FPD) frameworks with different cross-sectional areas and forms to evaluate the influence of connector design on fracture load. Each of the central, mesial and distal connectors was prepared with one of 2 different cross-sectional areas and one of 3 different forms (one circular and two oval forms) to give a total of 18 designs. Five frameworks were then prepared for each design, making a total of 90. Each framework was cemented to the test model with glass ionomer cement. Fracture load was measured with a universal testing machine at a cross-head speed of 1.0 mm/min. A three-way ANOVA revealed significant differences in fracture load depending on cross-sectional area, central connector cross-sectional form, or mesial/distal connector cross-sectional form (pdesign elements. The results of a Tukey analysis revealed a significant difference between the two connector cross-sectional areas investigated, with an increase in connector cross-sectional area resulting in an increase in fracture load. Fracture load decreased as the height of the mesial or distal connector decreased. Fracture load was significantly higher in frameworks in which the height of the central connector was greater than that of the distal or mesial connector. In conclusion, these results suggest that sufficient height needs to be maintained in the mesial/distal connector to secure a high fracture load in zirconia 4-unit all-ceramic FPDs. Moreover, even when this is not possible, a high fracture load may still be obtained by making the height of the central connector as great as possible. Furthermore, extending the connector cross-sectional area is effective in increasing fracture load.

  15. Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials

    Directory of Open Access Journals (Sweden)

    Vahideh Nazari

    2017-01-01

    Full Text Available Objectives: Fracture strength is an important factor influencing the clinical long-term success of implant-supported prostheses especially in high stress situations like excessive crown height space (CHS. The purpose of this study was to compare the fracture strength of implant-supported fixed partial dentures (FPDs with excessive crown height, fabricated from three different materials.Materials and Methods: Two implants with corresponding abutments were mounted in a metal model that simulated mandibular second premolar and second molar. Thirty 3-unit frameworks with supportive anatomical design were fabricated using zirconia, nickel-chromium alloy (Ni-Cr, and polyetheretherketone (PEEK (n=10. After veneering, the CHS was equal to 15mm. Then; samples were axially loaded on the center of pontics until fracture in a universal testing machine at a crosshead speed of 0.5 mm/minute. The failure load data were analyzed by one-way ANOVA and Games-Howell tests at significance level of 0.05.Results: The mean failure loads for zirconia, Ni-Cr and PEEK restorations were 2086±362N, 5591±1200N and 1430±262N, respectively. There were significant differences in the mean failure loads of the three groups (P<0.001. The fracture modes in zirconia, metal ceramic and PEEK restorations were cohesive, mixed and adhesive type, respectively.Conclusions: According to the findings of this study, all implant supported three-unit FPDs fabricated of zirconia, metal ceramic and PEEK materials are capable to withstand bite force (even para-functions in the molar region with excessive CHS.Keywords: Dental Implants; Polyetheretherketone; Zirconium oxide; Dental Restoration Failure; Dental Porcelain

  16. Evaluation of surface physical properties of acrylic resins for provisional prosthesis

    OpenAIRE

    Sérgio Paulo Hilgenberg; Emigdio Enrique Orellana-Jimenez; Wilmer Fabian Sepúlveda-Navarro; Beatriz Elena Arana-Correa; Dario César Teixeira Alves; Nara Hellen Campanha

    2008-01-01

    Acrylic resins used for provisional prostheses should have satisfactory superficial characteristics in order to ensure gingival health and low bacterial attachment. The purpose of the present study was to evaluate the superficial roughness and contact angle after two types of polishing and the Vickers hardness of three acrylic resins (Duralay - G1, Dencrilay - G2, and Dencor - G3), all shade 66, indicated for provisional fixed prostheses. Five 20 x 3 ± 1 mm diameter discoid specimens were obt...

  17. Clinical efficacy of veneered zirconium dioxide-based posterior partial fixed dental prostheses: five-year results.

    Science.gov (United States)

    Raigrodski, Ariel J; Yu, Alika; Chiche, Gerard J; Hochstedler, J L; Mancl, Lloyd A; Mohamed, Shawky E

    2012-10-01

    In recent years, zirconium dioxide-based partial fixed dental prostheses (FDP) have been suggested as an alternative treatment to traditional metal ceramic FDPs. However, clinical studies evaluating their longevity and related complications are limited. The purpose of this cohort clinical study was to assess the efficacy of zirconium dioxide-based posterior 3-unit FDPs. Twenty 3-unit posterior FDPs (Lava) were placed in 16 participants missing a second premolar or a first molar. All participants met specific inclusion and exclusion criteria and provided informed consent. All teeth were prepared in a standardized manner: occlusal reduction of 1.5 to 2 mm; axial reduction of 1 to 1.5 mm; a 1.0 mm 360-degree rounded shoulder placed 0.5 mm subgingivally on the facial aspect and supragingivally on the lingual aspect on sound tooth structure; and rounded internal line angles. Definitive impressions were made with vinyl polysiloxane impression material. Frameworks were fabricated by using computer-aided design and computer-aided manufacturing (CAD/CAM) technology with a uniform retainer thickness of 0.6 mm and a minimal connector surface area of 9 mm(2). Restorations were luted with resin-modified glass ionomer cement (Rely-X Luting). Participants were recalled at 2 weeks, 6 months, and 12 months, and thereafter, annually for up to 60 months. Clinical fracture measurements, marginal discoloration, marginal adaptation, radiographic proximal recurrent caries, and periapical pathoses were assessed over time by using modified Ryge criteria. The probability distributions of these variables were calculated for the baseline data and for the recall data. An analysis of survival was made by using the Kaplan-Meier method. Eighteen FDPs were clinically evaluated at 5 years and 1 at 48 months. Fifteen were rated Alpha for fracture measurements, and 2 were rated Bravo (minor chipping of veneering porcelain and not requiring restoration replacement). Two were rated Charlie (major

  18. A prospective 5-year study of fixed partial prostheses supported by implants with machined and TiO2-blasted surface

    DEFF Research Database (Denmark)

    Gotfredsen, K; Karlsson, U

    2001-01-01

    PURPOSE: The aim of the present study was to evaluate whether there was a difference between machined and TiO(2)-blasted implants regarding survival rate and marginal bone loss during a 5-year observation period. MATERIALS AND METHODS: A total of 133 implants (Astra Tech Dental Implants; Astra Tech...... AB, Mölndal, Sweden) were placed in 50 patients at 6 centers in 4 Scandinavian countries. Forty-eight implants were installed in the maxilla and 85 implants in the mandible. A randomization and a stratification were done, so that each fixed partial prosthesis was supported by at least 1 machined...... and 1 TiO(2)-blasted implant. The implant-supported fixed partial prostheses (ISFPP) were fabricated within 2 months after postoperative healing. A total of 52 ISFPP (17 maxillary, 35 mandibular) were inserted. The patients were clinically examined once a year for 5 years. At the annual follow...

  19. Prosthetic rehabilitation of mandibular defects with fixed-removable partial denture prosthesis using precision attachment: A twin case report

    OpenAIRE

    Vimal Kantilal Munot; Ramesh P Nayakar; Raghunath Patil

    2017-01-01

    The restoration of normal function and esthetic appearance with a dental prosthesis is a major challenge in the rehabilitation of patients who have lost their teeth and surrounding bone because of surgery for oral cyst or tumor. Rehabilitation with fixed or removable prosthesis is even more challenging when the edentulous span is long and the ridge is defective. Anatomic deformities and unfavorable biomechanics encountered in the region of resection add to the misery. In such situation, a fix...

  20. Prosthetic Rehabilitation of Mandibular Defects with Fixed-removable Partial Denture Prosthesis Using Precision Attachment: A Twin Case Report

    OpenAIRE

    Munot, Vimal Kantilal; Nayakar, Ramesh P; Patil, Raghunath

    2017-01-01

    The restoration of normal function and esthetic appearance with a dental prosthesis is a major challenge in the rehabilitation of patients who have lost their teeth and surrounding bone because of surgery for oral cyst or tumor. Rehabilitation with fixed or removable prosthesis is even more challenging when the edentulous span is long and the ridge is defective. Anatomic deformities and unfavorable biomechanics encountered in the region of resection add to the misery. In such situation, a fix...

  1. Prosthetic Rehabilitation of Mandibular Defects with Fixed-removable Partial Denture Prosthesis Using Precision Attachment: A Twin Case Report.

    Science.gov (United States)

    Munot, Vimal Kantilal; Nayakar, Ramesh P; Patil, Raghunath

    2017-01-01

    The restoration of normal function and esthetic appearance with a dental prosthesis is a major challenge in the rehabilitation of patients who have lost their teeth and surrounding bone because of surgery for oral cyst or tumor. Rehabilitation with fixed or removable prosthesis is even more challenging when the edentulous span is long and the ridge is defective. Anatomic deformities and unfavorable biomechanics encountered in the region of resection add to the misery. In such situation, a fixed-removable prosthesis allows favorable biomechanical stress distribution along with restoration of esthetics, phonetics, comfort, hygiene, and better postoperative care and maintenance. This article describes rehabilitation of two cases with mandibular defects with an attachment-retained fixed-removable hybrid prosthesis.

  2. Prosthetic rehabilitation of mandibular defects with fixed-removable partial denture prosthesis using precision attachment: A twin case report

    Directory of Open Access Journals (Sweden)

    Vimal Kantilal Munot

    2017-01-01

    Full Text Available The restoration of normal function and esthetic appearance with a dental prosthesis is a major challenge in the rehabilitation of patients who have lost their teeth and surrounding bone because of surgery for oral cyst or tumor. Rehabilitation with fixed or removable prosthesis is even more challenging when the edentulous span is long and the ridge is defective. Anatomic deformities and unfavorable biomechanics encountered in the region of resection add to the misery. In such situation, a fixed-removable prosthesis allows favorable biomechanical stress distribution along with restoration of esthetics, phonetics, comfort, hygiene, and better postoperative care and maintenance. This article describes rehabilitation of two cases with mandibular defects with an attachment-retained fixed-removable hybrid prosthesis.

  3. Complete mouth reconstruction with implant-supported fixed partial dental prostheses fabricated with zirconia frameworks: a 4-year clinical follow-up.

    Science.gov (United States)

    Puri, Shweta; Parciak, Ewa C; Kattadiyil, Mathew T

    2014-09-01

    Few scientific reports regarding the success of complete mouth partial fixed dental prostheses frameworks fabricated with zirconia are available, especially when dental implants serve as the abutments. A complete mouth reconstruction with zirconia frameworks veneered with feldspathic porcelain is reported involving a 65-year-old white woman who presented with partial edentulism and an unrestorable remaining dentition. After examination, 14 implants were planned (8 in the maxillary arch and 6 in the mandibular arch), and implant-supported zirconia framework screw-retained partial fixed dental prostheses (ISZPFDPs) were fabricated and made in sections for easier retrievability and management. No major complications were encountered during follow-up appointments at 6-month intervals for 4 years. However, minor fractures of the veneering ceramic were noted 4 years after placement. The ISZPFDPs were well accepted by the patient and had a favorable outcome in terms of patient acceptability and success, despite some complications. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  4. Axial Changes of Catalyst Structure and Temperature in a Fixed-Bed Microreactor During Noble Metal Catalysed Partial Oxidation of Methane

    DEFF Research Database (Denmark)

    Hannemann, S.; Grunwaldt, Jan-Dierk; Kimmerle, B.

    2009-01-01

    The catalytic partial oxidation of methane (CPO) over flame-made 2.5%Rh-2.5%Pt/Al2O3 and 2.5%Rh/Al2O3 in 6%CH4/3%O-2/He shows the potential of in situ studies using miniaturized fixed-bed reactors, the importance of spatially resolved studies and its combination with infrared thermography and on...... zone of the oxidation state/maximum in temperature towards the inlet. At the same time the hydrogen concentration in the reactor effluent increased. In contrast, at low temperatures a movement of the transition zone towards the outlet was observed at increasing flux, except if the self...... catalytic reactions involving different reaction zones and gradients even in micro scale fixed-bed reactors....

  5. Impact of prosthetic material on mid- and long-term outcome of dental implants supporting single crowns and fixed partial dentures: A systematic review and meta-analysis.

    Science.gov (United States)

    Abou-Ayash, Samir; Strasding, Malin; Rücker, Gerta; Att, Wael

    2017-01-01

    The impact of prosthetic material selection on implant survival is not clear. The current criteria for choosing a prosthetic material seem to be based on clinician preferences. This systematic review aims to evaluate the impact of restorative materials on the mid- and long-term survival of implants supporting single crowns and fixed partial dentures. Hand and MEDLINE searches were performed to identify relevant literature for single crowns (SC) and fixed partial dentures (FPD). Further inclusion criteria were a mean follow-up period of at least 3 years, the inclusion of at least 10 patients in a relevant study cohort, and a clear description of prosthesis type and prosthetic material. A total of 63 studies for the SC group and 11 studies for the FPD group were included. Full arch restorations were not included. The materials utilised in the SC group were metal-ceramic (precious and non-precious), lithium-disilicate, veneered zirconia, veneered alumina, and nanoceramics. The materials used in the FPD group were metal-ceramic (precious), veneered titanium, metal-resin (precious), and veneered zirconia. No significant impact on the prosthetic material relating to mid- or long-term implant survival was identified. Furthermore, there were no statistically significant differences between the survival rates of the dental prostheses made from different materials (SC and FPD group). Single crowns made of nanoceramics showed a higher risk for decementation relative to other materials (0.80, 95% CI [0.67; 0.89]; P material selection has no influence on mid- and long-term survival of implants restored with single crowns and fixed partial dentures. Similarly, the prosthetic material seems to have no significant impact on prosthetic survival rates. Further research is required to provide more evidence regarding the impact of the prosthetic material on long-term outcome. Conflict-of-interest statement: The authors declare that they have no conflict of interest.

  6. [Clinical evaluation of "All-on-Four" provisional prostheses reinforced with carbon fibers].

    Science.gov (United States)

    Li, Bei-bei; Lin, Ye; Cui, Hong-yan; Hao, Qiang; Xu, Jia-bin; Di, Ping

    2016-02-18

    the control group (P=0.001). No carbon fiber exposure and mucosal irritation were observed from clinical examination.SEM revealed relatively continuous contact between the fiber and acrylic resin, and the resin particles adhered on the surface of the carbon fibers. The addition of carbon fibers between abutments placed on "All-on-Four" provisional fixed denture base resin may be clinically effective in preventing "All-on-Four" denture fracture and can provide several advantages for clinical use.

  7. A prospective 5-year study of fixed partial prostheses supported by implants with machined and TiO2-blasted surface

    DEFF Research Database (Denmark)

    Gotfredsen, K; Karlsson, U

    2001-01-01

    PURPOSE: The aim of the present study was to evaluate whether there was a difference between machined and TiO(2)-blasted implants regarding survival rate and marginal bone loss during a 5-year observation period. MATERIALS AND METHODS: A total of 133 implants (Astra Tech Dental Implants; Astra Tech...... AB, Mölndal, Sweden) were placed in 50 patients at 6 centers in 4 Scandinavian countries. Forty-eight implants were installed in the maxilla and 85 implants in the mandible. A randomization and a stratification were done, so that each fixed partial prosthesis was supported by at least 1 machined...

  8. A 2-year report on maxillary and mandibular fixed partial dentures supported by Astra Tech dental implants. A comparison of 2 implants with different surface textures

    DEFF Research Database (Denmark)

    Karlsson, U; Gotfredsen, K; Olsson, C

    1998-01-01

    In 50 partially edentulous patients, 133 (48 maxillary; 85 mandibular) Astra Tech dental implants of 2 different surface textures (machined; TiO-blasted) were alternately installed, supporting 52 fixed partial dentures (FPDs). Before abutment connection 2 machined implants (1 mandibular; 1...... maxillary) were found to be non-osseointegrated and were replaced. Another implant could not be restored due to a technical complication. Two FPDs were remade because of technical complications, both because of abutment fractures. Thus, after 2 years in function, the cumulative survival rates were 97.......7% and 95.7% for implants and prostheses, respectively. There was no statistically significant difference in survival rate between the 2 types of implants, 100% (TiO-blasted) vs 95.3% (machined), P = 0.24. After 2 years in function, when both jaw and type of implants were combined, the mean (SD) marginal...

  9. A Spaceborne Synthetic Aperture Radar Partial Fixed-Point Imaging System Using a Field- Programmable Gate Array−Application-Specific Integrated Circuit Hybrid Heterogeneous Parallel Acceleration Technique

    Directory of Open Access Journals (Sweden)

    Chen Yang

    2017-06-01

    Full Text Available With the development of satellite load technology and very large scale integrated (VLSI circuit technology, onboard real-time synthetic aperture radar (SAR imaging systems have become a solution for allowing rapid response to disasters. A key goal of the onboard SAR imaging system design is to achieve high real-time processing performance with severe size, weight, and power consumption constraints. In this paper, we analyse the computational burden of the commonly used chirp scaling (CS SAR imaging algorithm. To reduce the system hardware cost, we propose a partial fixed-point processing scheme. The fast Fourier transform (FFT, which is the most computation-sensitive operation in the CS algorithm, is processed with fixed-point, while other operations are processed with single precision floating-point. With the proposed fixed-point processing error propagation model, the fixed-point processing word length is determined. The fidelity and accuracy relative to conventional ground-based software processors is verified by evaluating both the point target imaging quality and the actual scene imaging quality. As a proof of concept, a field- programmable gate array−application-specific integrated circuit (FPGA-ASIC hybrid heterogeneous parallel accelerating architecture is designed and realized. The customized fixed-point FFT is implemented using the 130 nm complementary metal oxide semiconductor (CMOS technology as a co-processor of the Xilinx xc6vlx760t FPGA. A single processing board requires 12 s and consumes 21 W to focus a 50-km swath width, 5-m resolution stripmap SAR raw data with a granularity of 16,384 × 16,384.

  10. A Spaceborne Synthetic Aperture Radar Partial Fixed-Point Imaging System Using a Field- Programmable Gate Array-Application-Specific Integrated Circuit Hybrid Heterogeneous Parallel Acceleration Technique.

    Science.gov (United States)

    Yang, Chen; Li, Bingyi; Chen, Liang; Wei, Chunpeng; Xie, Yizhuang; Chen, He; Yu, Wenyue

    2017-06-24

    With the development of satellite load technology and very large scale integrated (VLSI) circuit technology, onboard real-time synthetic aperture radar (SAR) imaging systems have become a solution for allowing rapid response to disasters. A key goal of the onboard SAR imaging system design is to achieve high real-time processing performance with severe size, weight, and power consumption constraints. In this paper, we analyse the computational burden of the commonly used chirp scaling (CS) SAR imaging algorithm. To reduce the system hardware cost, we propose a partial fixed-point processing scheme. The fast Fourier transform (FFT), which is the most computation-sensitive operation in the CS algorithm, is processed with fixed-point, while other operations are processed with single precision floating-point. With the proposed fixed-point processing error propagation model, the fixed-point processing word length is determined. The fidelity and accuracy relative to conventional ground-based software processors is verified by evaluating both the point target imaging quality and the actual scene imaging quality. As a proof of concept, a field- programmable gate array-application-specific integrated circuit (FPGA-ASIC) hybrid heterogeneous parallel accelerating architecture is designed and realized. The customized fixed-point FFT is implemented using the 130 nm complementary metal oxide semiconductor (CMOS) technology as a co-processor of the Xilinx xc6vlx760t FPGA. A single processing board requires 12 s and consumes 21 W to focus a 50-km swath width, 5-m resolution stripmap SAR raw data with a granularity of 16,384 × 16,384.

  11. Occlusion for implant-supported fixed dental prostheses in partially edentulous patients: a literature review and current concepts

    OpenAIRE

    Yuan, Judy Chia-Chun; Sukotjo, Cortino

    2013-01-01

    Implant treatment has become the treatment of choice to replace missing teeth in partially edentulous areas. Dental implants present different biological and biomechanical characteristics than natural teeth. Occlusion is considered to be one of the most important factors contributing to implant success. Most literature on implant occlusal concepts is based on expert opinion, anecdotal experiences, in vitro and animal studies, and only limited clinical research. Furthermore, scientific literat...

  12. Immediate placement and functional loading of implants on canine with fixed partial denture for a patient having canine protected occlusion: a case report

    Science.gov (United States)

    Hong, Jun-Won; Ahn, Seung-Geun; Leem, Dae-Ho

    2012-01-01

    Conventional implant protocols required a load-free healing period of three to six months between placement and functional loading of the implants. Many efforts have been made to minimize the duration of treatment time. Several literatures have documented immediate function with provisional or definitive prosthesis within a week of the placement in response to these demands. In addition, immediate implant placement has advantages such as shortened treatment time and preservation of soft tissue architectures. This article presents immediate implant placement into fresh extraction sockets followed by functional immediate loading with provisional prosthesis on canine and premolars for a patient having canine protected occlusion. PMID:22439101

  13. Effect of the number of implants on stress distribution of anterior implant-supported fixed prostheses combined with a removable partial denture: a finite element analysis.

    Science.gov (United States)

    Mahshid, Minoo; Geramy, Allahyar; Ejlali, Massoud; Sedaghat Monfared, Majid; Rezvani Habib Abadi, Shirin

    2014-05-01

    The main goal of this study was to evaluate differences in stress distribution relevant to the number of implants under an anterior bridge when combined with a removable partial denture in the posterior region. Four three-dimensional finite element models (3D FEM) were designed from a mandible containing an implant-supported bridge extending between canines, and a bilateral distal extension removable partial denture. A nonrigid connection was selected as the attachment method between the partial denture and the anterior implant-supported fixed prosthesis; 2, 3, 4 and 5 implants supporting the bridge all with 10mm length and 3.8 mm diameter were assessed. With the aid of the finite element program ANSYS 8.0, the models were loaded and von Mises stresses were evaluated. In spongy bone, stress forces showed a decrease from 2 implants to 4 implants but showed an increase in the 5-implant model. Stresses on cortical bone of terminal implants were in similar range in the 2-, 3- and 4-implant models. While, in the 5-implant model the amount of stresses on terminal implants increased dramatically. The stresses on implants were nearly similar in all models, with the greatest amount on terminal implants. Within the limitations of this study, 2-, 3- and 4-implant models showed less stress on cortical and spongy bone in comparison with the 5-implant model. The stresses transferred to implants were nearly similar.

  14. Effect of the number of implants on stress distribution of anterior implant-supported fixed prostheses combined with a removable partial denture: a finite element analysis.

    Directory of Open Access Journals (Sweden)

    Minoo Mahshid

    2014-06-01

    Full Text Available The main goal of this study was to evaluate differences in stress distribution relevant to the number of implants under an anterior bridge when combined with a removable partial denture in the posterior region.Four three-dimensional finite element models (3D FEM were designed from a mandible containing an implant-supported bridge extending between canines, and a bilateral distal extension removable partial denture. A nonrigid connection was selected as the attachment method between the partial denture and the anterior implant-supported fixed prosthesis; 2, 3, 4 and 5 implants supporting the bridge all with 10mm length and 3.8 mm diameter were assessed. With the aid of the finite element program ANSYS 8.0, the models were loaded and von Mises stresses were evaluated.In spongy bone, stress forces showed a decrease from 2 implants to 4 implants but showed an increase in the 5-implant model. Stresses on cortical bone of terminal implants were in similar range in the 2-, 3- and 4-implant models. While, in the 5-implant model the amount of stresses on terminal implants increased dramatically. The stresses on implants were nearly similar in all models, with the greatest amount on terminal implants.Within the limitations of this study, 2-, 3- and 4-implant models showed less stress on cortical and spongy bone in comparison with the 5-implant model. The stresses transferred to implants were nearly similar.

  15. VSRR Provisional Drug Overdose Death Counts

    Data.gov (United States)

    U.S. Department of Health & Human Services — This data contains provisional counts for drug overdose deaths based on a current flow of mortality data in the National Vital Statistics System. National...

  16. The effect of screw preload and framework material on the success of cementable fixed partial prostheses: A finite element study.

    Science.gov (United States)

    Hasan, Istabrak; Keilig, Ludger; Bourauel, Christoph; Lückerath, Walter

    2015-05-01

    The rigidity of framework materials and overload of the implant system directly affect the final transferred load of the bone around implants. The aim of the present study has been to analyse the influence of framework materials on the transferred load to the implant system and the surrounding bone. A finite element model of a long-span cementable implant-supported fixed prosthesis was created with two coping layers (gold and hybrid composite) to optimise the fitting of the prosthesis to the abutments. Three framework materials were analysed: titanium, gold alloy, and zirconia. The connection screws were first preloaded with 200 N. The framework was then loaded with 500 N vertically and at 30° to the framework long axis. Two loading conditions were considered: at the mesial and distal boundaries of the framework and at the centre of the framework. The stresses and strains within the framework materials and bone bed around the supporting implants were analysed. The region and angle of load applications showed an obvious effect on the values of the stresses and strains within the framework itself and, consequently, their distribution in the implant system and surrounding bone. A correlation of the framework material and stresses of the coping materials was observed as well. The gold framework showed acceptable values of stress within the cortical bone (92 MPa and 89 MPa with 30° loading at two points and at the centre, respectively) in comparison to titanium (92 MPa and 113 MPa) and zirconia (88 MPa and 115 MPa). Copyright © 2014 Elsevier GmbH. All rights reserved.

  17. Four-millimeter implants supporting fixed partial dental prostheses in the severely resorbed posterior mandible: two-year results.

    Science.gov (United States)

    Slotte, Christer; Grønningsaeter, Arne; Halmøy, Anne-Marie; Öhrnell, Lars-Olof; Stroh, Göran; Isaksson, Sten; Johansson, Lars-Åke; Mordenfeld, Arne; Eklund, Jan; Embring, Jan

    2012-05-01

    Reduced alveolar bone volume complicates implant dentistry. In this prospective multicenter study, a new, 4-mm long Straumann SLActive implant (Ø 4.1 mm) supporting a fixed dental prosthesis (FDP) in the severely resorbed posterior mandible was evaluated for two years. Thirty-two patients (11 men, 21 women; mean age 64.1 years) participated. Ten to 12 weeks after single-stage surgery, a screw-retained FDP was attached to three or four 4-mm implants. One hundred implants were inserted. Three failed at surgery and four were lost before loading. Twenty-eight patients received FDPs (93 implants). Two patients were discontinued because of secondary exclusion criteria; therefore, 26 patients were followed up from baseline (BL). After 1 year, one patient insisted on removal of all implants and one patient died because of nonstudy-related complications. Twenty-four patients (87 implants) were eligible for examination 2 years post-loading. All implants were found to be stable [survival rate 95.7% (confidence interval, CI 88.8-98.3) after 1 year and 92.3% (CI 84.5-96.2) after 2 years]. The mean change from BL to 12 months was - 0.43 mm (CI 0.31-0.59; p care to avoid overdrilling. Careful planning and design of the prosthetic construction is mandatory to prevent unfavorable occlusion and avoid harmful shear forces. This study showed that 4 mm implants can support an FDP in severely resorbed posterior mandibles for at least 2 years and with healthy peri-implant conditions. © 2011 Wiley Periodicals, Inc.

  18. Outcome of zirconia partial fixed dental prostheses made by predoctoral dental students: A clinical retrospective study after 3 to 7 years of clinical service.

    Science.gov (United States)

    Pihlaja, Juha; Näpänkangas, Ritva; Raustia, Aune

    2016-07-01

    Zirconia has an established role in fixed prosthodontics, especially for single crowns. Whether it is durable enough for fixed dental prostheses (FDPs) in the long term is yet unclear. The purpose of this retrospective study was to evaluate the outcome of FDPs made by predoctoral students after 3 to 7 years of clinical service. A total of 102 patients received 120 zirconia FDPs (range, 3-12 units; mean, 4.5 units) between 2007 and 2010. Materials used were Zirkonzahn Zirconia (Zirkonzahn), NobelProcera Zirconia (Nobel Biocare), and Prettau Zirconia (Zirkonzahn). Veneering porcelain was hand-layered on Zirkonzahn Zirconia (GC Initial Zr; GC Europe) and Nobel Procera Zirconia (VITA VM 9; VITA Zahnfabrik). Prettau Zirconia was monolithic and had no veneering porcelain. Success and survival rates were calculated using Kaplan-Meier survival analysis. Ethics approval was obtained from the Ethical Committee of the Northern Ostrobothnia Hospital District (100/2013). The 76 participants examined (75%) had received 88 zirconia FDPs. The mean follow-up period was 4.9 years (range, 3-7 years). The most common complication was chipping of the veneering porcelain in 13 of 88 FDPs (14.7%). The success rate of the zirconia-based partial FDPs after 4.9 years was 89%, and the survival rate was 100%. The success rate of the zirconia-based partial FDPs after 4.9 years was 89%, and the survival rate was 100%. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  19. Finite element analysis to compare stress distribution of gold alloy, lithium-disilicate reinforced glass ceramic and zirconia based fixed partial denture.

    Science.gov (United States)

    Zheng, Zhiqiang; Lin, Jie; Shinya, Akikazu; Matinlinna, Jukka P; Botelho, Michael G; Shinya, Akiyoshi

    2012-11-01

    Clinical data indicate that veneer chipping of zirconia core is more likely than with ceramic-fused-to-metal structures. The purposes of this simulation study were to: (a) use two-dimensional finite element modeling to simulate stresses at the interface of three-unit posterior fixed partial dentures (FPDs) made with three different core materials; and (b) to investigate the influence of three different veneer thicknesses on the stress distribution within the veneer-core complex. A mesio-distal cross-section of a three-unit FPD was digitized and used to create two-dimensional models of the teeth, supporting bone, different core materials (gold alloy, zirconia and lithia-disilicate reinforced glass ceramic), and different pontic preparation configurations (occlusal veneer thickness 1.0, 1.5, and 2.0 mm). A simulated 100 N vertical occlusal load was applied to the standardized pontic element. Compression stress and tensile stress values were calculated by finite element analysis along the veneer-core interface and compared. The veneer-core interfacial stress of zirconia-based FPD is greater than that of gold alloy and lithium-disilicate reinforced glass ceramic core. The veneer-core interface stress value decreased with increasing occlusal veneer thickness. Finite element modeling revealed differences in tensile and compressive stresses between different pontic preparation configurations and core materials. In general, gold alloy and lithium-disilicate reinforced glass ceramic core provided more even stress distribution at the connector and pontic of fixed partial denture than a zirconia framework. © 2012 Wiley Publishing Asia Pty Ltd.

  20. Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures

    Directory of Open Access Journals (Sweden)

    Valdey SUEDAM

    2016-04-01

    Full Text Available ABSTRACT Because many mechanical variables are present in the oral cavity, the proper load transfer between the prosthesis and the bone is important for treatment planning and for the longevity of the implant-supported fixed partial denture. Objectives To verify the stress generated on the peri-implant area of cantilevered implant-supported fixed partial dentures and the potential effects of such variable. Material and Methods A U-shaped polyurethane model simulating the mandibular bone containing two implants (Ø 3.75 mm was used. Six groups were formed according to the alloy’s framework (CoCr or PdAg and the point of load application (5 mm, 10 mm and 15 mm of cantilever arm. A 300 N load was applied in pre-determined reference points. The tension generated on the mesial, lingual, distal and buccal sides of the peri-implant regions was assessed using strain gauges. Results Two-way ANOVA and Tukey statistical tests were applied showing significant differences (p<0.05 between the groups. Pearson correlation test (p<0.05 was applied showing positive correlations between the increase of the cantilever arm and the deformation of the peri-implant area. Conclusions This report demonstrated the CoCr alloy shows larger compression values compared to the PdAg alloy for the same distances of cantilever. The point of load application influences the deformation on the peri-implant area, increasing in accordance with the increase of the lever arm.

  1. Comparison of fiber reinforcement placed at different locations of pontic in interim fixed partial denture to prevent fracture: An in vitro study.

    Science.gov (United States)

    Kapri, Surg Cdr Anita

    2015-01-01

    The interim restoration is an important phase in fixed prosthodontic therapy. It should provide sufficient durability to withstand the forces of mastication. A fractured interim restoration is damaging to the prosthodontic care and may lead to an unscheduled appointment for repair. Several attempts have been made to reinforce interim fixed partial dentures (FPDs). These have included the use of metal wire, a lingual cast metal reinforcement, a processed acrylic resin interim restoration, and different types of fibers, e.g., carbon, polyethylene, nylon and glass. These fibers can be placed in the occlusal, middle or cervical thirds in the FPD. There is no scientific data to evaluate the effect of fiber placement methods on the fracture resistance of clinical interim FPDs. Hence this study was designed to evaluate fracture load values of interim FPDs with different locations of fiber reinforcement. 30 interim FPD samples with polymethyl methacrylate (PMMA) reinforced with fibers at three different locations mainly occlusal, cervical and middle (10 samples each) were fabricated using a metal FPD on a master die. They were tested for fracture resistance in universal testing machine. The fracture resistance was recorded and is tabulated and analyzed statistically. The results showed that the placement of the reinforcement in the occlusal third of the pontic resulted in higher fracture resistance which was significantly higher (P fiber for reinforcing the PMMA interim restorative resin.

  2. Immediate provisional restoration of a single-tooth implant in the esthetic zone: A case report

    Directory of Open Access Journals (Sweden)

    Po-Sung Fu

    2011-02-01

    Full Text Available Immediate implant restoration of single implants may demonstrate a positive effect on peri-implant soft tissue. Placement of a provisional restoration following implant surgery can create soft tissue contours that resemble normal gingival topography before placement of the definitive prosthesis. This article describes a staged approach of the mandibular permanent right central incisor, which was congenital missing. The proper space for restoration of the missing incisor was created through orthodontic treatment. The scheduled implant site was reconstructed using autogenous bone harvested from the chin region. After a healing period of four months, an implant was installed with the connection of a fixed provisional crown to a prefabricated temporary abutment. The soft tissue around the implant healed according to the contours of the provisional restoration and the emergence profile was used to duplicate the definitive restoration. Peri-implant esthetics was achieved through the staged approach and immediate restoration of the implant.

  3. Immediate placement and functional loading of implants on canine with fixed partial denture for a patient having canine protected occlusion: a case report

    OpenAIRE

    Hong, Jun-Won; Ahn, Seung-Geun; Leem, Dae-Ho; Seo, Jae-Min

    2012-01-01

    Conventional implant protocols required a load-free healing period of three to six months between placement and functional loading of the implants. Many efforts have been made to minimize the duration of treatment time. Several literatures have documented immediate function with provisional or definitive prosthesis within a week of the placement in response to these demands. In addition, immediate implant placement has advantages such as shortened treatment time and preservation of soft tissu...

  4. Effect of nightguard vital bleaching gel on the color stability of provisional restorative materials.

    Science.gov (United States)

    Bajunaid, Salwa Omar

    2016-01-01

    To assess the hypothesis that there was no difference in effect of 10% and 15% tooth bleaching agents on color stability of materials used for provisional fixed dental prosthesis. Fifteen samples from two materials used for provisional fixed dental prosthesis: methacrylate-based and composite-based materials and 15 preformed polycarbonate crowns soaked in bleaching gel or distilled water. Spectrophotometer recorded color of specimens at baseline, after 3, 7, and 14 days. Data were statistically analyzed using two-factor ANOVA test to compare the color stability of tested materials. Methyl-based provisional material exhibited statistically higher color change when exposed to 10% and 15% bleaching gel (delta EFNx01: 9.0 and 11.1, respectively) as compared to distilled water (delta EFNx01: 2.9). Delta EFNx01 of composite-based material specimens exposed to distilled water was statistically higher (6.3) than specimens exposed to 10% and 15% bleaching gel (1.5 and 1.1, respectively). Polycarbonate crowns showed a statistically lower color change when exposed to 15% (0.9) than to 10% bleaching gel (5.1) or distilled water (5.5). Composite-based provisional material showed highest color stability when exposed to vital tooth bleaching gel, whereas methacrylate-based material was the least color stable. Polycarbonate crowns were more color stable when exposed to 15% bleaching gel as opposed to 10% bleaching gel.

  5. Comparative evaluation of stresses in tooth implant connected fixed partial denture by varying the implant design and position: A 3D finite element study

    Directory of Open Access Journals (Sweden)

    K V Pratheep

    2013-01-01

    Full Text Available Aim: This study aims at evaluating stresses generated in a fixed tooth to implant connected fixed partial denture (FPD by finite element method by varying implant design and position, in unilateral distal extension cases, i.e. for replacing mandibular 1 st and 2 nd molars. Materials and Methods: Four models were created, Model 1-A finite element model (FEA model of a crestal implant-tooth connected metal ceramic FPD with pontic in 36 region. The 35 region simulated the second premolar. Model 2-A FEA model of a basal implant-tooth connected metal ceramic FPD. Model 3-A FEA model of a crestal implant in 36 region connected to tooth 35 and cantilevered posteriorly with pontic in 37 region, made of metal ceramic. Model 4-A FEA model of a basal implant in 36 region connected to tooth 35 and cantilevered posteriorly with pontic in 37 region, made of metal ceramic. A vertical force of 100N directed evenly on the nodes on the occlusal surface of each of the three crowns. The models displayed stress both numerically and by color coding. Results: On comparing models 1 and 2, the model 1 showed comparatively more stresses in crestal bone area of the implant. On comparing models 3 and 4, model 3 showed lesser von misses stress values. Conclusion: In case of tooth implant connected FPDs without any cantilevers, basal implants show better stress distribution when compared to crestal implants. In case of cantilever designs, crestal implant design showed lower stress values, but the difference in stresses were less.

  6. Achieve efficient nitrogen removal from real sewage in a plug-flow integrated fixed-film activated sludge (IFAS) reactor via partial nitritation/anammox pathway.

    Science.gov (United States)

    Yang, Yandong; Zhang, Liang; Cheng, Jun; Zhang, Shujun; Li, Baikun; Peng, Yongzhen

    2017-09-01

    This study tested the feasibility of plug-flow integrated fixed-film activated sludge (IFAS) reactor in applying sewage partial nitritation/anammox (PN/A) process. The IFAS reactor was fed with real pre-treated sewage (C/N ratio=1.3) and operated for 200days. High nitrogen removal efficiency of 82% was achieved with nitrogen removal rates of 0.097±0.019kgN/(m(3)·d). Therefore, plug-flow IFAS reactor could be an alternative to applying sewage PN/A process. Besides, it was found that the stability of sewage PN/A process was significantly affected by residual ammonium. Nitrate accumulated in effluent and PN/A performance deteriorated when residual ammonium was below 1mg/L. On the contrary, long-term stable PN/A operation was achieved when residual ammonium was over 3mg/L. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Transition from failing dentition to full-arch fixed implant-supported prosthesis with a staged approach using removable partial dentures: a case series.

    Science.gov (United States)

    Cortes, Arthur Rodriguez Gonzalez; Cortes, Djalma Nogueira; No-Cortes, Juliana; Arita, Emiko Saito

    2014-06-01

    The present retrospective case series is aimed at evaluating a staged approach using a removable partial denture (RPD) as an interim prosthesis in treatment to correct a failing dentition until such time as a full-arch fixed implant-supported prosthesis may be inserted. Eight patients, who had undergone maxillary full-arch rehabilitation with dental implants due to poor prognosis of their dentitions, were analyzed. All treatment included initial periodontal therapy and a strategic order of extraction of hopeless teeth. An RPD supported by selected teeth rehabilitated the compromised arch during implant osseointegration. These remaining teeth were extracted prior to definitive prosthesis delivery. Advantages and drawbacks of this technique were also recorded for the cases presented. Among the advantages provided by the staged approach are simplicity of fabrication, low cost, and ease of insertion. Additionally, RPD tooth support prevented contact between the interim prosthesis and healing abutments, promoting implant osseointegration. The main drawbacks were interference with speech and limited esthetic results. Implant survival rate was 100% within a follow-up of at least 1 year. The use of RPDs as interim prostheses allowed for the accomplishment of the analyzed rehabilitation treatments. It is a simple treatment alternative for patients with a low smile line. © 2013 by the American College of Prosthodontists.

  8. 14 CFR 121.207 - Provisionally certificated airplanes: Operating limitations.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Provisionally certificated airplanes... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Airplane Performance Operating Limitations § 121.207 Provisionally certificated airplanes: Operating limitations. In...

  9. VSRR - Provisional monthly number of live births by state

    Data.gov (United States)

    U.S. Department of Health & Human Services — https://www.cdc.gov/nchs/products/vsrr/provisional-tables.htm Monthly provisional counts of births are provided by state of residence (50 states, District of...

  10. VSRR - Provisional monthly number of deaths by state

    Data.gov (United States)

    U.S. Department of Health & Human Services — https://www.cdc.gov/nchs/products/vsrr/provisional-tables.htm Monthly provisional counts of deaths and infant deaths are provided by state of residence (50 states,...

  11. Generalized provisional seed zones for native plants

    Science.gov (United States)

    Andrew D. Bower; J. Bradley St.Clair; Vicky. Erickson

    2014-01-01

    Deploying well-adapted and ecologically appropriate plant materials is a core component of successful restoration projects. We have developed generalized provisional seed zones that can be applied to any plant species in the United States to help guide seed movement. These seed zones are based on the intersection of high-resolution climatic data for winter minimum...

  12. INTERACTIVE NAME PLACEMENT FOR PROVISIONAL MAPS.

    Science.gov (United States)

    Goldberg, Jeffrey L.; Miller, Thomas C.

    1983-01-01

    Computer generation and placement of map type has been refined into a production mode at Mid-Continent Mapping Center (MCMC) for USGS 1:24,000- and 1:25,000-scale Provisional maps. The map collar program is written in FORTRAN using batch processing that allows the program to work in the background.

  13. VSRR - Quarterly provisional estimates for infant mortality

    Data.gov (United States)

    U.S. Department of Health & Human Services — Provisional estimates of infant mortality (deaths of infants under 1 year per 1,000 live births), neonatal mortality (deaths of infants aged 0-27 days per 1,000 live...

  14. All-ceramic and porcelain-fused-to-metal fixed partial dentures: a comparative study by 2D finite element analyses

    Directory of Open Access Journals (Sweden)

    Andréa Barreira Motta

    2007-10-01

    Full Text Available All-ceramic fixed partial dentures (FPDs have an esthetic approach for oral rehabilitation. However, metal-ceramic FPDs are best indicated in the posterior area where the follow-up studies found a lower failure rate. This 2D finite element study compared the stress distribution on 3-unit all-ceramic and metal-ceramic FPDs and identified the areas of major risk of failure. Three FPD models were designed: (1 metal-ceramic FPD; (2 All-ceramic FPD with the veneering porcelain on the occlusal and cervical surface of the abutment tooth; (3 All-ceramic FPD with the veneering porcelain only on the occlusal surface. A 100 N load was applied in an area of 0.5 mm² on the working cusps, following these simulations: (1 on the abutment teeth and the pontic; (2 only on the abutment teeth; and (3 only on the pontic. Relative to the maximum stress values found for the physiological load, all-ceramic FPD with only occlusal veneering porcelain produced the lowest stress value (220 MPa, followed by all-ceramic FPD with cervical veneering porcelain (322 MPa and metal-ceramic FPD (387 MPa. The stress distribution of the load applied on the abutments was significantly better compared to the other two load simulations. The highest principal stress values were low and limited in a small area for the three types of models under this load. When the load was applied on the pontic, the highest stress values appeared on the connector areas between the abutments and pontic. In conclusion, the best stress values and distribution were found for the all-ceramic FPD with the veneering porcelain only on the occlusal surface. However, in under clinical conditions, fatigue conditions and restoration defects must be considered.

  15. Success, clinical performance and patient satisfaction of direct fibre-reinforced composite fixed partial dentures - a two-year clinical study.

    Science.gov (United States)

    Malmstrom, H; Dellanzo-Savu, A; Xiao, J; Feng, C; Jabeen, A; Romero, M; Huang, J; Ren, Y; Yunker, M A

    2015-12-01

    To evaluate the success, clinical performance and patient satisfaction of directly placed fibre-reinforced composite (FRC) fixed partial dentures (FPDs) in 2 years. One hundred sixty-seven FRC FPDs (120 subjects) were directly fabricated to restore a single missing tooth by six Advanced Education in General Dentistry (AEGD) residents. The FRC FPDs recipients were randomised into two groups according to the fibre materials (pre-impregnated glass or polyethylene). Clinical performance was evaluated at baseline (2 weeks), 6, 12 and 24 months by two calibrated evaluators for prosthesis adaptation, colour match, marginal discoloration, surface roughness, caries and post-operative sensitivity using modified United State Public Health Service (USPHS) criteria. Prosthesis appearance, colour, chewing ability and overall satisfaction were evaluated by patients using a visual analogue scale (VAS). Kaplan-Meier estimation was used to estimate the prosthesis success. Ninety-four patients with 137 FRC FPDs returned (21·67% attrition rate for study subjects, 17·94% for FRC FPDs). Seventeen FRC FPDs failed, due to one-end (n = 4) or two-ends (n = 4) debonding or pontic fracture (n = 9). The cumulative 2-year success rate was 84·32% and survival rate was 92·7%; there were no statistically significant differences between the groups according to different missing tooth location, retention type or fibre materials (P > 0·05). Patient satisfaction regarding prosthesis appearance, col-our, chewing ability and overall satisfaction was rated high on the VAS (mean >80 mm) for all criteria at all time points. The FRC FPDs (restoring single tooth) fabricated by AEGD residents achieved acceptable success and survival rates in a 2-year follow-up. © 2015 John Wiley & Sons Ltd.

  16. Immediate loading of immediate mandibular implants with a full-arch fixed prosthesis: a preliminary study.

    Science.gov (United States)

    Peñarrocha, Miguel; Boronat, Araceli; Garcia, Berta

    2009-06-01

    To determine the survival of immediate dental implants with immediate loading in the partially edentulous mandible, by use of a full-arch screw-retained provisional restoration. Patients who were partially edentulous in the mandible with indications for extraction of the remaining teeth and with a minimum follow-up of 12 months after implant placement were included in the study. They were treated in chronologic order by the insertion of 6 Defcon dental implants (Impladent, Sentmenat, Spain) subjected to immediate loading (4 interforaminal and 2 posterior placements). Implants with a minimum primary stability of 60 implant stability quotient were loaded. All resin screw-retained prostheses were inserted and loaded with fully functional occlusion within 24 hours of implant placement. Eleven patients were treated with immediate implants, although 2 patients were excluded from the study for having an implant stability quotient value below 60 in at least one of the implants after surgery and did not undergo restoration with immediate loading. Fifty-four implants were placed in 9 partially edentulous patients with immediate loading with a full-arch screw-fixed prosthesis. The patients wore this provisional prosthesis during the healing period (2 months) without complication and with a high level of comfort. The survival rate of the implants was 100% at 12 months of follow-up. Immediate mandibular loading with immediate full-arch implant-supported and screw-retained restorations is a viable treatment alternative, yielding a 100% success rate in this small series of patients.

  17. Biological and technical complications and failures with fixed partial dentures (FPD) on implants and teeth after four to five years of function.

    Science.gov (United States)

    Brägger, U; Aeschlimann, S; Bürgin, W; Hämmerle, C H; Lang, N P

    2001-02-01

    The aim of this study was to compare the frequency of biological and technical complications with fixed partial dentures (FPDs) on implants, teeth and as mixed tooth-implant supported FPDs over 4 to 5 years of function. All implants belonged to the ITI Dental Implant System. Group I-I (implant FPD) included 33 patients with 40 FPDs, group T-T (tooth FPDs) 40 patients with 58 FPDs, group I-T (mixed tooth-implant FPDs) 15 with 18 FPD. Of the bridge abutments 144 were teeth and 105 were implants. The median number of units replaced by the FPDs was 3 (range 2-14). The mean age of the patients was 55.7 years (range 23-83). Complete failures resulted in the loss of one FPD in each group. Two implants were lost due to fracture secondarily to development of a bone defect. One tooth had a vertical fracture and 1 tooth was lost due to periodontitis. Biological complications (peri-implantitis, PPD > or = 5 mm and BOP+) occurred at 9.6% (10) of the implants. This number was, however, reduced to 5% if the threshold for definition of peri-implantitis was set at PPD > or = 6 mm and BOP+. Biological complications occurred in 11.8% (17) of the abutment teeth (NS compared to implants); 2.8% (4) had secondary caries, 4.9% (7) endodontic problems and 4.1% (6) had periodontitis (PPD > or = 5 mm, BOP+). Ten out of 32 patients with a general health problem indicated a biological complication, whereas 9 out of 53 patients with no general health problem had a biological complication (chi 2: NS). Statistically significantly more technical complications were found in FPDs on implants (chi 2, P bruxism. Out of 10 bruxers 6 had a technical complication whereas 13 out of 75 non-bruxers had such a complication (chi 2 implant abutments after 4-5 years of function. Loss of FPD over 4-5 years occurred at a similar rate with mixed, implant or tooth supported reconstructions. Significantly more porcelain fractures were found in FPDs on implants. Impaired general health status was not significantly

  18. Use of intraoral welding to stabilize dental implants in augmented sites for immediate provisionalization: a case report.

    Science.gov (United States)

    Avvanzo, Pierluigi; Fabrocini, Lelio A; Ciavarella, Domenico; Avvanzo, Andrea; Lo Muzio, Lorenzo; De Maio, Raffaele A

    2012-02-01

    Immediate implant rehabilitation of edentulous arches may be somewhat problematic because of anatomic situations involving insufficient bone thickness or height and tooth position. The aim of this report was to present a retrospective case series of dental implants placed into augmented sites (split crest or sinus augmentation) that were stabilized with an intraorally welded framework at the time of immediate provisionalization. An intraoral welding unit was used to join and stabilize implants as an orthopedic splint to break down forces applied on provisional restorations during healing and osseointegration. This approach allows for the immediate provisionalization of implants in bone-defective areas where multiple implant systems have been enacted. Forty-eight implants in 16 patients were inserted, welded together to a titanium framework, and immediately provisionalized during the same surgery in which split-crest or sinus augmentation procedures were performed. After removing the welded frameworks, 1 of 48 implants failed; the failed implant was associated with a sinus augmentation procedure. Intraoral welding stabilization may be a predictable procedure to allow immediate loading in augmented areas during healing time and to stabilize implants against nonaxial forces, thereby reducing the number of surgical and prosthetic sessions and making patients comfortable and accustomed to immediate fixed provisional and definitive restorations.

  19. Esthetic transformation of a failed implant reconstruction to fixed-supported prosthesis: a case report.

    Science.gov (United States)

    Cascione, Domenico; Nowzari, Hessam; Reshad, Mamaly

    2012-06-01

    This article describes a clinical situation where an ill-fitting prosthesis supported by malpositioned dental implants was esthetically transformed to fixed definitive restorations. Provisional restorations were used as a blueprint for fabrication of definitive restorations.

  20. Retrospective analysis of porcelain failures of metal ceramic crowns and fixed partial dentures supported by 729 implants in 152 patients: patient-specific and implant-specific predictors of ceramic failure.

    Science.gov (United States)

    Kinsel, Richard P; Lin, Dongming

    2009-06-01

    Porcelain fracture associated with an implant-supported, metal ceramic crown or fixed partial denture occurs at a higher rate than in tooth-supported restorations, according to the literature. Implant-specific and patient-specific causes of ceramic failure have not been fully evaluated. The purpose of this retrospective study was to evaluate the potential statistical predictors for porcelain fracture of implant-supported, metal ceramic restorations. Over a 6-month period, a consecutive series of patients having previously received implant-supported, metal ceramic fixed restorations were examined during periodic recall appointments. The number of supporting implants, number of dental units, type of restoration, date of prosthesis insertion, location in the dental arch, opposing dentition, type of occlusion, presence of parafunctional habits, use of an occlusal protective device, presence or absence of ceramic fractures, gender, and age were recorded for each patient. The generalized estimating equation (GEE) approach was used for the intrasubject correlated measurements analysis of categorical outcomes (presence or absence of ceramic fractures) to determine which patient- and implant-specific factors would predict porcelain fracture (alpha=.05). Data were collected from 152 patients representing 998 dental units (390 single crowns and 94 fixed partial dentures) supported by 729 implants. Porcelain fractures of 94 dental units occurred in 35 patients. The fractures were significantly (Pimplant-supported metal ceramic restorations, bruxism, and not wearing a protective occlusal device. Metal ceramic prostheses (single crown or fixed partial dentures) had approximately 7 times higher odds of porcelain fracture (odds ratio (OR)=7.06; 95% confidence interval (CI): 2.57 to 19.37) and 13 times greater odds of a fracture requiring either repair or replacement (OR=13.95; 95% CI: 2.25 to 86.41) when in occlusion with another implant-supported restoration, as compared to

  1. Early loading of splinted implants supporting a two-unit fixed partial denture in the posterior maxilla: 13-month results from a randomized controlled clinical trial of two different implant systems.

    Science.gov (United States)

    Ryu, Hyo-Sook; Namgung, Cheol; Heo, Young-Ku; Lee, Jong-Ho; Lim, Young-Jun

    2016-08-01

    The aim of this study was to evaluate early-loaded implants supporting a two-unit fixed dental prosthesis in the posterior maxilla and to compare the clinical and radiological outcomes of two different implant systems in terms of success rates, implant stability quotient (ISQ) values, and peri-implant parameters. Thirty patients with the unilateral loss of two consecutive maxillary posterior teeth were randomly assigned to two different implant systems: SLActive Bone level implant (Institut Straumann AG, Basel, Switzerland) in the control group and CMI IS-II active implant (Neobiotech Co., Seoul, Korea) in the experimental group. The patients received provisional and definitive two-unit fixed prostheses at 4 weeks and 6 months after implant surgery, respectively. The peak insertion torque was recorded at surgery. The stability of each implant was evaluated during surgery and at 2, 3, and 4 weeks and 6 and 13 months after implant placement by means of ISQ values. In addition, periapical radiographs and peri-implant parameters were taken throughout the trial. Overall, comparable results were obtained between the control and experimental groups in terms of insertion torque, ISQ values, marginal bone loss, and peri-implant soft tissue parameters. All 60 implants had 100% of success rate. The average insertion torque was 36.83 ± 6.09 (control) and 35.33 ± 3.20 (test) Ncm. The ISQ values remained steady until 4 weeks and then increased with statistical significance during 4 weeks to 13 months after surgery. Both groups exhibited no stability dip during the early phase of healing. The average marginal bone loss from the baseline of implant placement for the control and experimental groups was 0.38 and 0.45 mm after 4 weeks and 0.98 and 0.61 mm after 13 months. All of the soft tissue parameters were within normal limits. The results of this study indicate that the concept of early loading at 4 weeks after placement in the posterior maxilla can be an effective

  2. 2012 Provisional classification criteria for polymyalgia rheumatica

    DEFF Research Database (Denmark)

    Dasgupta, Bhaskar; Cimmino, Marco A; Kremers, Hilal Maradit

    2012-01-01

    % and specificity to 81%. According to these provisional classification criteria, patients ≥50 years old presenting with bilateral shoulder pain, not better explained by an alternative pathology, can be classified as having PMR in the presence of morning stiffness >45 minutes, elevated C-reactive protein and......The objective of this study was to develop European League Against Rheumatism/American College of Rheumatology classification criteria for polymyalgia rheumatica (PMR). Candidate criteria were evaluated in a 6-month prospective cohort study of 125 patients with new-onset PMR and 169 non......-PMR comparison subjects with conditions mimicking PMR. A scoring algorithm was developed based on morning stiffness >45 minutes (2 points), hip pain/limited range of motion (1 point), absence of rheumatoid factor and/or anti-citrullinated protein antibody (2 points), and absence of peripheral joint pain (1 point...

  3. Evaluation of Vertical Marginal Adaptation of Provisional Crowns by ...

    African Journals Online (AJOL)

    2018-01-30

    Jan 30, 2018 ... Abduo J, Lyons K, Swain M. Fit of zirconia fixed partial denture: A systematic review. J Oral Rehabil 2010;37:866‑76. 16. Colpani JT, Borba M, Della Bona A. Evaluation of marginal and internal fit of ceramic crown Copings. Dent Mater. 2013;29:174‑80.doi: 10.1016/j.dental.2012.10.012. 17. Habib SR, Asiri ...

  4. Immediate loading in the maxilla using flapless surgery, implants placed in predetermined positions, and prefabricated provisional restorations: a retrospective 3-year clinical study.

    Science.gov (United States)

    Rocci, Antonio; Martignoni, Massimiliano; Gottlow, Jan

    2003-01-01

    Immediate loading of dental implants shortens the treatment time and makes it possible to give the patient an esthetic appearance during the whole treatment period. The aim of the present study was to evaluate an immediate-loading treatment protocol, which included flapless surgery, implants placed in predetermined positions and connected to prefabricated provisional restorations, and the 3-year clinical results. A total of 97 Brånemark System Mk IV implants (Nobel Biocare AB, Gothenburg, Sweden) with a machined surface were inserted in the maxillas of 46 patients. A presurgical three-dimensional model of the patients' soft tissue and underlying alveolar bone anatomy was created, which allowed the clinician to place the implants in predetermined positions and connect them to prefabricated provisional restorations. A surgical template with drilling guides corresponding to each implant was used. The apical part of the master guide was equipped with a circular "mucotome," which punched out a 5 mm hole in the mucosa to eliminate the need for flap elevation. The patients received 25 fixed partial prostheses and 27 single-tooth restorations. Bone quality and quantity were assessed. Radiographic examinations were performed on the day of surgery/loading and at the 1-, 2-, and 3-year follow-up visits. All implant sites showed intact buccal and lingual bone walls during surgery, confirming the accuracy of the bone-mapping procedure. The prefabricated temporary restorations fitted, meaning that the implants were positioned clinically in the same way as on the cast. Nine implants in eight patients failed during the first 8 weeks of loading. This resulted in a cumulative survival rate of 91% after 3 years of prosthetic load. The survival rate of splinted implants was 94%. The number of failed implants was significantly higher in cases of single-tooth replacements and placement in soft bone sites and smokers. The failed implants were successfully replaced according to a two

  5. The Overall Survival, Complication-Free Survival, and Related Complications of Combined Tooth-Implant Fixed Partial Dentures: A Literature Review

    Directory of Open Access Journals (Sweden)

    Peter Borg

    2016-05-01

    Full Text Available This paper reviews the literature regarding possible complications, complication-free survival, and overall survival of fixed dental prostheses that use both implants and natural teeth as abutments. The paper also provides clinical guidelines for treatment based on this literature review. An electronic search utilizing the MEDLINE, BIOSIS Citation Index, and Web of Science™ Core Collection databases was undertaken, and a review of the 25 selected texts studying 22 different patient cohorts was carried out. From a total of 1610 implants reviewed, 40 were lost (33 due to loss of integration and 7 due to fracture, whereas, out of a total of 1301 teeth, 38 were lost, of which 16 were due to fracture. Seventy-three cases of tooth intrusion were detected. From a total of 676 frameworks reviewed (metal n = 645, Zirconia n = 31, 7 fractured, while veneer material fracture occurred in 70 out of 672 bridges. Overall, 502 out of 531 tooth-implant fixed prostheses (TIPFs remained functional, and 336 out of 439 prostheses showed no technical or biological complications and remained functional. Rigid TIFPs permanently cemented to teeth with sufficient coronal structure and with limited use of prosthetic attachments offer a good long-term treatment option to patients with good oral hygiene following sound implant placement. This mode of treatment should be used when free-standing implant-supported options may not be possible. Larger randomized control studies and other clinical studies comparing tooth-to-implant-connected treatment with other forms of treatment are needed to better understand the place of TIFP treatment in oral rehabilitation.

  6. VSRR - Quarterly provisional estimates for selected birth indicators

    Data.gov (United States)

    U.S. Department of Health & Human Services — Provisional estimates of selected reproductive indicators. Estimates are presented for: general fertility rates, age-specific birth rates, total and low risk...

  7. VSRR - Quarterly provisional estimates for selected indicators of mortality

    Data.gov (United States)

    U.S. Department of Health & Human Services — Provisional estimates of death rates. Estimates are presented for each of the 15 leading causes of death plus estimates for deaths attributed to drug overdose, falls...

  8. Emergency department external fixation for provisional treatment of pilon and unstable ankle fractures

    Directory of Open Access Journals (Sweden)

    Craig R Lareau

    2015-01-01

    Full Text Available Unstable ankle fractures and impacted tibial pilon fractures often benefit from provisional external fixation as a temporizing measure prior to definitive fixation. Benefits of external fixation include improved articular alignment, decreased articular impaction, and soft tissue rest. Uniplanar external fixator placement in the Emergency Department (ED ex-fix is a reliable and safe technique for achieving ankle reduction and stability while awaiting definitive fixation. This procedure involves placing transverse proximal tibial and calcaneal traction pins and connecting the pins with two external fixator rods. This technique is particularly useful in austere environments or when the operating room is not immediately available. Additionally, this bedside intervention prevents the patient from requiring general anesthesia and may be a cost-effective strategy for decreasing valuable operating time. The ED ex-fix is an especially valuable procedure in busy trauma centers and during mass casualty events, in which resources may be limited.

  9. PSYCHOACOUSTICS - A SELECTED BIBLIOGRAPHY. A PROVISIONAL BIBLIOGRAPHY.

    Science.gov (United States)

    DIMMICK, KENNETH

    THE 346 ENTRIES IN THIS BIBLIOGRAPHY COVER MATERIAL IN BOOKS, JOURNALS, AND MONOGRAPHS IN FIELDS RELATED TO THE SENSORY IMPAIRED, ESPECIALLY THE BLIND AND PARTIALLY SIGHTED. THE DATES RANGE FROM 1934 TO 1965. (MK)

  10. Two general fixed point principles and applications

    Directory of Open Access Journals (Sweden)

    Bapurao C. Dhage

    2016-06-01

    Full Text Available We present a couple of general fixed point principles using the constructive approach and derive some interesting well-known fixed point theorems in a metric space and a partially ordered metric space as corollaries. Our general fixed point principles include more than 100 fixed point theorems in different metric spaces as special cases.

  11. Stress distribution in fixed-partial prosthesis and peri-implant bone tissue with different framework materials and vertical misfit levels: a three-dimensional finite element analysis.

    Science.gov (United States)

    Bacchi, Ataís; Consani, Rafael L X; Mesquita, Marcelo F; dos Santos, Mateus B F

    2013-09-01

    The purpose of this study was to evaluate the influence of superstructure material and vertical misfits on the stresses created in an implant-supported partial prosthesis. A three-dimensional (3-D) finite element model was prepared based on common clinical data. The posterior part of a severely resorbed jaw with two osseointegrated implants at the second premolar and second molar regions was modeled using specific modeling software (SolidWorks 2010). Finite element models were created by importing the solid model into mechanical simulation software (ANSYS Workbench 11). The models were divided into groups according to the prosthesis framework material (type IV gold alloy, silver-palladium alloy, commercially pure titanium, cobalt-chromium alloy, or zirconia) and vertical misfit level (10 µm, 50 µm, and 100 µm) created at one implant-prosthesis interface. The gap of the vertical misfit was set to be closed and the stress values were measured in the framework, porcelain veneer, retention screw, and bone tissue. Stiffer materials led to higher stress concentration in the framework and increased stress values in the retention screw, while in the same circumstances, the porcelain veneer showed lower stress values, and there was no significant difference in stress in the peri-implant bone tissue. A considerable increase in stress concentration was observed in all the structures evaluated within the misfit amplification. The framework material influenced the stress concentration in the prosthetic structures and retention screw, but not that in bone tissue. All the structures were significantly influenced by the increase in the misfit levels.

  12. Immediate restoration of fixed partial prostheses supported by one-piece narrow-diameter selective laser sintering implants: a 2-year prospective study in the posterior jaws of 16 patients.

    Science.gov (United States)

    Mangano, Francesco; Pozzi-Taubert, Samuele; Zecca, Piero A; Luongo, Giuseppe; Sammons, Rachel L; Mangano, Carlo

    2013-08-01

    Selective laser sintering (SLS) is a new technique that allows implants to be produced by annealing titanium powder microparticles in a focused laser beam, according to a computer-generated model. The aim of this study was to evaluate the survival and success rate of immediately restored 1-piece narrow-diameter SLS implants, placed in the posterior jaws, after 2 years of functional loading. At the 2-year follow-up examination, several parameters were assessed. Success criteria included absence of pain, suppuration, exudation, implant mobility; distance between the implant shoulder and the first visible bone-to-implant contact <2.0 mm; and absence of prosthetic complications. Thirty-seven implants were placed in the posterior jaws (14 maxilla, 23 mandible) of 16 patients (9 males, 7 females). The prosthetic restorations comprised 16 immediately restored fixed partial prostheses. No implant failure occurred, resulting in a 100% survival rate. The implant success was 94.6%, and the mean distance between the implant shoulder and the first visible bone-to-implant contact (DIB) was 0.4 ± 0.3 mm. This study supports the hypothesis that 1-piece narrow-diameter SLS implants can be used in fixed prosthetic rehabilitations in the posterior regions of both jaws with a predictable positive outcome.

  13. Fix it or discard it? A retrospective analysis of functional outcomes after surgically treated patella fractures comparing ORIF with partial patellectomy.

    Science.gov (United States)

    Bonnaig, Nicolas S; Casstevens, Chris; Archdeacon, Michael T; Connelly, Camille; Monaco, Nathan; Wyrick, John D; Le, Theodore T

    2015-02-01

    The goal of this study was to compare functional outcomes of patients with patella fractures treated with open reduction and internal fixation (ORIF) with those treated with partial patellectomy (PP). Retrospective cohort study. Urban Level I Trauma Center. Seventy-three patients with isolated displaced patella fractures underwent operative treatment between January 1, 2002, and December 31, 2009, at our institution. Of these, 52 (71%) patients with isolated patella fractures with minimum 1-year follow-up agreed to participate and were enrolled in the study. PP or ORIF. Patients completed outcome questionnaires and participated in a physical examination. Outcome instruments included the Knee Outcome Survey-Activities of Daily Living Scale, Short Form (SF)-36 Health Survey, and SF Musculoskeletal Function Assessment Survey. Twenty-six patients underwent PP and 26 underwent ORIF. There were no significant differences in any of the functional outcome instruments, including Knee Outcome Survey-Activities of Daily Living Scale (ORIF: 64.1 ± 11, PP: 62.1 ± 7.9, P = 0.76), SF-36 physical component score (ORIF: 40.8 ± 5.4, PP: 41.1 ± 5.2, P = 0.94), SF-36 mental component (ORIF: 47.7 ± 5.1, PP: 51.8 ± 4.9, P = 0.19), Short Musculoskeletal Function Assessment (SMFA) Function Index (ORIF: 28.6 ± 9.1, PP: 27.7 ± 6.7, P = 0.78), or SMFA Bother Index (ORIF: 26.0 ± 9.7, PP: 23.6 ± 8.8, P = 0.72). Complication rates did not differ significantly between the 2 groups. This study demonstrates that functional impairment persists after operative treatment of patella fractures. Both ORIF and PP demonstrated similar final range of motion, functional scores, and complication rates. Despite its purported benefits, in this study, ORIF did not result in superior outcomes compared with PP. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  14. Fixed Points

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 5; Issue 5. Fixed Points - From Russia with Love - A Primer of Fixed Point Theory. A K Vijaykumar. Book Review Volume 5 Issue 5 May 2000 pp 101-102. Fulltext. Click here to view fulltext PDF. Permanent link:

  15. Finite element analysis of provisional structures of implant-supported complete prostheses.

    Science.gov (United States)

    Carneiro, Bruno Albuquerque; de Brito, Rui Barbosa; França, Fabiana Mantovani Gomes

    2014-04-01

    The use of provisional resin implant-supported complete dentures is a fast and safe procedure to restore mastication and esthetics of patients soon after surgery and during the adaptation phase to the new denture. This study assessed stress distribution of provisional implant-supported fixed dentures and the all-on-4 concept using self-curing acrylic resin (Tempron) and bis-acrylic resin (Luxatemp) to simulate functional loads through the three-dimensional finite element method. Solidworks software was used to build three-dimensional models using acrylic resin (Tempron, model A) and bis-acrylic resin (Luxatemp, model B) for denture captions. Two loading patterns were applied on each model: (1) right unilateral axial loading of 150 N on the occlusal surfaces of posterior teeth and (2) oblique loading vector of 150 N at 45°. The results showed that higher stress was found on the bone crest below oblique load application with a maximum value of 187.57 MPa on model A and 167.45 MPa on model B. It was concluded that model B improved stress distribution on the denture compared with model A.

  16. Evaluation of surface physical properties of acrylic resins for provisional prosthesis

    Directory of Open Access Journals (Sweden)

    Sérgio Paulo Hilgenberg

    2008-09-01

    Full Text Available Acrylic resins used for provisional prostheses should have satisfactory superficial characteristics in order to ensure gingival health and low bacterial attachment. The purpose of the present study was to evaluate the superficial roughness and contact angle after two types of polishing and the Vickers hardness of three acrylic resins (Duralay - G1, Dencrilay - G2, and Dencor - G3, all shade 66, indicated for provisional fixed prostheses. Five 20 x 3 ± 1 mm diameter discoid specimens were obtained for each group. One side of the specimens was subjected to standard polishing (pumice and whiting slurry, and the opposite side was polished with special tips. The mean roughness and contact angles of the materials were measured. The specimens were subjected to the Vickers microhardness test, which indicated that standard polishing produced a surface roughness equivalent to that of the special tips. The contact angles obtained with the standard polishing were equivalent to those observed in the special tips group. The microhardness of G1 and G3 resins showed statistical differences.

  17. Technology and the use of acrylics for provisional dentine protection.

    Science.gov (United States)

    Kapusevska, Biljana; Dereban, Nikola; Popovska, Mirjana; Nikolovska, Julijana; Radojkova Nikolovska, Vеrа; Zabokova Bilbilova, Efka; Mijoska, Aneta

    2013-01-01

    Acrylics are compounds polymerized from monomers of acrylic, metacrylic acid or acrylonitrates. The purpose of this paper is to present the technology and use of acrylics for provisional dentine protection in the practice of dental prosthodontics. For this reason, we followed 120 clinical cases from the everyday clinical practice, divided into 4 groups of 30 patients who needed prosthetic reconstruction. The first group included cases in which we applied celluloid crowns for dentine protection, for the second group we used acrylic teeth from a set of teeth for complete dentures; in the third and fourth groups the fabrication was done with the system of an impression matrix and the acrylic resin block technique respectively. In all the examined patients, the gingival index by Silness and Loe and the vitality of the dental pulp were verified clinically, after preparation and 8 days from the placement of the provisional crown. The value for dental sensitivity measured after preparation was 2.59, and 8 days after the placement of the provisional crown it bwas 3.1. From these results we can conclude that after the 8th day from the placement of the provisional crown, there was an adaptation period, characterized by a decrease in the painful sensations. The value of the Silness and Loe gingival index measured after the preparation was 1.34, and 8 days from the placement of the provisional crown was 0.94. The results inclined us to the fact that the provisional acrylic crowns facilitated the reparation of the periodontal tissue.

  18. La ejecución provisional de las sentencias

    OpenAIRE

    Silva Álvarez,Óscar

    2008-01-01

    Dentro de la corriente reformista del proceso civil en Chile, un lugar importante debería estar ocupado por la figura de la ejecución provisional de las sentencias judiciales, como una manifestación del derecho a la tutela judicial efectiva y un instrumento para el acortamiento de los tiempos en el proceso. El presente artículo contiene un examen teórico a la figura de la ejecución provisional, y establece las reglas técnicas de su configuración legal. También analiza los aislados casos de ta...

  19. Fix 40!

    Index Scriptorium Estoniae

    2008-01-01

    Ansambel Fix peab 13. detsembril Tallinnas Saku Suurhallis oma 40. sünnipäeva. Kontserdi erikülaline on ansambel Apelsin, kaastegevad Jassi Zahharov ja HaleBopp Singers. Õhtut juhib Tarmo Leinatamm

  20. Occlusal wear of provisional implant-supported restorations

    NARCIS (Netherlands)

    Santing, Hendrik J.; Kleverlaan, Cornelis J.; Werner, Arie; Feilzer, Albert J.; Raghoebar, Gerry M.; Meijer, Henny J. A.

    BACKGROUND: Implant-supported provisional restorations should be resistant to occlusal wear. PURPOSE: The purpose of this laboratory study was to evaluate three-body wear of three indirect laboratory composite resins, five chair side bis-acryl resin-based materials, and two chair side

  1. Evaluation of Vertical Marginal Adaptation of Provisional Crowns by ...

    African Journals Online (AJOL)

    2018-01-30

    Jan 30, 2018 ... Department of Prosthetic Dental Sciences, College of Dentistry,. King Saud University, Riyadh, Kingdom of Saudi Arabia. E‑mail: malrifaiy@hotmail.com. How to cite this article: Al Rifaiy MQ. Evaluation of vertical marginal adaptation of provisional crowns by digital microscope. Niger J Clin Pract. 2017 ...

  2. The management of an edentulous maxilla using a CAD/CAM-guided immediately loaded provisional implant prosthesis with screw-retained and cement-retained abutments: a clinical report.

    Science.gov (United States)

    Tee-Khin, Neo; Cheng, Ansgar C; Lee, Helena; Wee, Alvin G

    2009-12-01

    Functional rehabilitation of edentulous jaws using a CAD/CAM-guided implant protocol is commonly recommended as a definitive treatment modality. A patient with an edentulous maxilla received 7 endosseous implants using a CAD/CAM surgical template. A provisional maxillary acrylic resin fixed complete denture was connected immediately after implant placement using a combination of screw-retained and cement-retained abutments.

  3. Immediate occlusal loading of Tapered Internal Laser-Lok® implants in partial arch rehabilitations: a 24-months clinical and radiographic study

    Directory of Open Access Journals (Sweden)

    M. Grande

    2013-10-01

    Full Text Available Aim The purpose of this 2 year prospective clinical study was to clinically and radiographically evaluate an implant with laser microtextured collar surface placed for immediate loading of fixed prostheses in cases of partial posterior maxillary and/or mandibular edentulism.Materials and methods Thirty-five partially edentulous patients who needed implant treatment and met inclusion criterias were consecutively enrolled at different study-centers in Italy. A total of 107 Tapered Internal Laser-Lok® implants (49 maxillary and 58 mandibular were placed and immediately loaded. All provisional constructions were delivered within 1 hour, and the final constructions placed after 4 months. A total of 107 Tapered Internal Laser-Lok implants (49 maxillary and 58 mandibular were placed and immediately loaded. All provisional restorations were delivered within 1 hour, and the final prosthesis placed after 4 months. A total of 32 prosthetic restorations, consisting of 10 two- units, 12 three-units, and 10 four-units fixed partial dentures were evaluated. Clinical and radiographic outcomes were monitored at follow-up examinations scheduled 6, 12, 24 months after implants placement.Results Five implants were lost after loading (3 implants in a two-unit maxillary restorations, 1 implant in a two-unit mandibular restorations, and 1 implant in three-unit maxillary restorationsgiving a survival rate of 95.4% after 24 months. Mean crestal bone loss at 6, 12, and 24 months after implant insertion was 0.42 +/- 1.1 mm, 0.52 +/- 0.9 mm, and 0.66 +/- 1.3 mm, respectively.Conclusion Although limited bytheshort follow-up, immediate function with Tapered Internal Laser-Lok® implants seems to be a viable option to treat partially edentulous patients.

  4. Bacterial leakage of provisional restorative materials used in endodontics.

    Science.gov (United States)

    Hartwell, Gary R; Loucks, Carina A; Reavley, Brenton A

    2010-04-01

    To test the bacterial sealing ability of commonly used provisional endodontic restorative materials. This study investigated Cavit (3M ESPE), Ketac (3M ESPE), DuoTemp (Coltane/Whaledent), and a combination technique using Ketac and Cavit. One hundred molars were randomly selected and then mounted in an apparatus that isolated the crown portion of the tooth. Provisional restorative materials were placed in an open access following manufacturer guidelines. Streptococcus mutans was applied to the samples, and results were tabulated over the course of 4 weeks. Cavit and DuoTemp performed the best, and Ketac performed the worst. After 14 days, however, all materials leaked in over half of the samples. No material can be recommended as superior in providing a reliable seal after 14 days.

  5. Provisional Crown Dislodgement during Scuba Diving: A Case of Barotrauma

    OpenAIRE

    Meenal Nitin Gulve; Nitin Dilip Gulve

    2013-01-01

    Changes in ambient pressure, for example, during flying, diving, or hyperbaric oxygen therapy, can lead to barotrauma. Although it may seem that this issue was neglected in dental education and research in recent decades, familiarity with and understanding of these facts may be of importance for dental practitioners. We report the case of a patient who experienced barotrauma involving dislodgement of a provisional crown during scuba diving. Patients who are exposed to pressure changes as a pa...

  6. Immediately Loaded Intraorally Welded Complete-Arch Maxillary Provisional Prosthesis.

    Science.gov (United States)

    Albiero, Alberto Maria; Benato, Renato; Fincato, Andrea

    2015-01-01

    Guided implant surgery is not completely accurate when using computer-designed stereolithographic surgical guides. Complications are frequently reported when combining computer-guided flapless surgery with an immediately loaded prefabricated prosthesis. Achieving passive fit of a prefabricated prosthesis on the inserted implants the same day of the surgery can be difficult. The aim of this report is to show a new treatment approach to immediately loaded implants inserted with computer-guided surgery using an intraoral welded full-arch provisional prosthesis.

  7. In vitro color stability of provisional restorative materials

    Directory of Open Access Journals (Sweden)

    Hamid Jalali

    2012-01-01

    Aims: The purpose of this study was to investigate the effect of tea on provisional restorative materials. Setting and Design: This study was designed to measure the degree of color change of three acrylic resin provisional materials, before and after immersion in artificial saliva and artificial saliva-tea solution for 2 and 4 weeks. Materials and Methods : Three types of acrylic provisional materials (duralay, tempron, acropars TRP, were studied. Twenty disks (20±0.1 mm by 2±0.05 mm were fabricated from each material. Specimens were polished with acrylic bur using pumice and diamond polishing paste. Base line color was measured using a spectrophotometer. Ten disks were stored in artificial saliva and 10 were stored in a solution of artificial saliva and tea at room temperature. Color measurements were made after 2 and 4 weeks of immersion. Statistical analysis used: Differences in color changes were compared by two way ANOVA, across the six groups, followed by a Turkey-Kramer′s multiple comparison test. Results: For specimens immersed in artificial saliva, the color change of methyl methacrylate materials; duralay (ΔE=4.94 and tempron (ΔE=6.54, was significantly more than butyl methacrylate material; acropars (ΔE=4.10. After immersion in an artificial saliva- tea solution, tempron exhibited less color change (ΔE=8.50 compared to duralay (ΔE=10.93 and acropars (ΔE=15.64. Conclusion: Color stability of methyl methacrylate is higher than butyl methacrylates so if provisional materials are used for extended periods of time; tempron is preferred.

  8. Analysis of colour stability of selected provisional prosthetic materials: an in vitro study.

    Science.gov (United States)

    Koczorowski, Ryszard; Linkowska-Swidzińska, Kamila; Gedrange, Tomasz; Swidziński, Teodor

    2009-08-01

    Prosthetic restorative materials (that are) used for temporary fixed dentures tend to exhibit variable discolouration over several weeks of use. The aim of this study was to perform a spectrophotometric analysis of the influence of selected discolouring factors on the colour stability of provisional prosthetic materials in vitro. In the study, the following prosthetic materials for short-term use in the oral cavity were evaluated: Luxatemp, Structur 2S.C., Protemp II, Zhermacryl STC and Dentalon Plus. Samples of these materials were immersed in coffee, tea and dark fruit juice for 60 h at different pH values. Colour was evaluated by determining the monochromatic coefficients of light reflected by the samples, using a spectrophotometric method. Results received in artificial light (illuminant A) were compared with those obtained in daylight (illuminant D65). Changes in colour and its parameters according to the CIE L*a*b* system were analysed. The analysis (of the colour and colour parameters) of the tested materials in two types of light showed that Structur displayed the greatest tendency to discolouration and that the least tendency to discolouration was exhibited by Dentalon Plus. The fact that colour parameters obtained in two types of light were not identical suggests that changes in the colour of the same material may be perceived differently, depending on the illuminant. Provisional prosthetic materials show variable colour stability under different conditions in the oral cavity. The colour of prosthetic materials may be perceived differently, depending on the illuminant and the effect of the environment in which they are used.

  9. In Vitro Comparison of Marginal and Internal Fit of Press-on-Metal Ceramic (PoM) Restorations with Zirconium-Supported and Conventional Metal Ceramic Fixed Partial Dentures Before and After Veneering.

    Science.gov (United States)

    Varol, Seda; Kulak-Özkan, Yasemin

    2015-07-01

    To compare marginal and internal fit between 3- and 4-unit press-on-metal (PoM) ceramic, zirconia-supported, and conventional metal ceramic fixed partial dentures (FPDs) before and after veneering. Ten pieces for each 3- and 4-unit MC, IPS InLine PoM, and IPS e.max ZirCAD/Zir Press FPDs were produced. Cross-sections from silicone replicas were examined and measured with a light microscope. Occlusal, axial, intermarginal, and marginal mean adaptation scores of cross-sectioned replicas and means of measurements obtained from 4 sites were calculated independently. Mean values for molars were 78.44 ± 32.01 μm (MC), 89.84 ± 29.20 μm (PoM), and 85.17 ± 28.49 μm (Zir). Premolar values were 76.08 ± 27.92 μm (MC), 89.94 ± 23.49 μm (PoM), and 87.18 ± 28.25 μm (Zir). No difference existed between the means of 3- and 4-unit FPDs except the molar-intermarginal region. The mean value of 4-unit FPDs (93.88 ± 25.41 μm) was less than the 3-unit FPDs (103.68 ± 24.55 μm) at the molar-inter marginal region. A gap increase was observed in all sites except the molar-axio-occlusal region after veneering. According to the mean difference, gap increases at the molar-marginal, molar-intermarginal, and premolar-intermarginal regions were statistically significant. A statistical difference was found at the molar-marginal region for 4-unit MCR (p = 0.041) and 4-unit PoM FPDs (p = 0.042) before and after veneering. Gap increase after veneering of 4-unit metal ceramics at molar-intermarginal, premolar-marginal, and premolar-intermarginal regions (p = 0.020; p = 0.015; p = 0.004) was significant. The gap measurements of the IPS InLine PoM and IPS e.max ZirCAD/Zir Press groups were all clinically acceptable. No studies on marginal and internal fit in the IPS InLine PoM system have been published to date. This study should be supported with future studies. No significant increase was observed after press-veneering the IPS e.max ZirCAD frameworks with an IPS e.max ZirPress material

  10. Restoration of failing maxillary implant-supported fixed prosthesis with cross arch splinted unilateral zygomatic implant: a clinical report.

    Science.gov (United States)

    Gunaseelan, Rajan; Saravanakumar, Mariappan; Hariharan, Ramasubramanian

    2012-12-01

    Management of one or more failing distal implants in an implant supported fixed prosthesis in a completely edentulous maxilla creates a challenging situation. Restoring immediate function with additional implants in such a situation can be a challenge considering the loss of supporting bone, need for grafting, age, and the patient's desire for immediate fixed dental prosthesis. This clinical report describes a situation where a zygomatic implant has been placed unilaterally and splinted with osseointegrated conventional implants by an immediate fixed provisional restoration.

  11. Effect of Provisional Cements on Shear Bond Strength of Porcelain Laminate Veneers

    OpenAIRE

    Altintas, Subutay Han; Tak, Onjen; Secilmis, Asli; Usumez, Aslihan

    2011-01-01

    Objectives: The purpose of this study was to evaluate the effect of three provisional cements and two cleaning techniques on the final bond strength of porcelain laminate veneers. Methods: The occlusal third of the crowns of forty molar teeth were sectioned and embedded in autopolymerizing acrylic resin. Dentin surfaces were polished and specimens were randomly divided into four groups (n=10). Provisional restorations were fabricated and two provisional restorations were cemented onto each to...

  12. Provisional drivers' perceptions of the impact of displaying P plates.

    Science.gov (United States)

    Bates, Lyndel; Scott-Parker, Bridie; Darvell, Millie; Watson, Barry

    2017-11-17

    P plates (or decals) identify a driver's license status to other road users. They are a compulsory part of the graduated driver licensing system in Queensland, Australia, for drivers on a P1 (provisional 1) or P2 (provisional 2) license. This study explored the perceptions of young drivers regarding the display of P plates (decals) in Queensland, Australia. In this study, 226 young drivers with a provisional (intermediate/restricted) license completed a 30-min online survey between October 2013 and June 2014. t Tests were used to compare the opinions of people who displayed their plates nearly always with those who displayed them less frequently. Participants approved of the requirement to display P plates with 69% of those on a P1 license and 79% on a P2 license supporting the condition to display P1 (red) plates. Participants on a P1 license (62%) and a P2 license (68%) also approved the requirement to display P2 (green) plates. However, young drivers also perceived that the display of P plates (measured from 1 = never to 5 = nearly all the time) enabled newly licensed drivers to be targeted by police and other drivers (those who do not always display P plates: M = 3.72, SD = 0.94; those who nearly always display P plates: M = 3.43, SD = 1.09). The study findings suggest that participants who nearly always display their P plates are more likely to report that having to display their plates resulted in them driving more carefully.

  13. Fiber-reinforced fixed partial dentures: a preliminary retrospective clinical study Próteses parciais fixas reforçadas por fibras: um estudo clínico retrospectivo preliminar

    Directory of Open Access Journals (Sweden)

    Edno Moacir Piovesan

    2006-04-01

    Full Text Available The aim of this study was to evaluate the clinical performance (retention rate of fiber-reinforced composite fixed partial dentures (FPDs. Polyethylene fiber (Ribbond® was used combined with restorative composite during FPDs fabrication. FPDs were placed in thirteen patients in a private clinic. Nineteen FPDs were evaluated. The prosthetic space was filled with only one pontic using extracted teeth (2 cases, acrylic resin teeth (11 cases, or with composite resin (6 cases, combined with Polyethylene fiber. The clinical criterion used was based on retention rate of FPDs. If FPDs were in function in the mouth at the time of examination without previous repair they were classified as Complete Survival (CS restorations. A classification of Survival with Rebonding (SR was assigned in the event of an adhesive failure, but after rebonding the FPD still remained under evaluation. Treatment was classified as a Failure (F if the FPD restoration was lost. The time of evaluation was 41.15 months (±15.13. The FPDs evaluated were retained (CS=94.75%, and no failure was found except for in one situation which required rebonding (SR=5.25%. According to the survival estimation method of Kaplan-Meyer the mean survival time was 42.3 months. At the time of evaluation investigated, polyethylene-reinforced FPDs showed a favorable retention rate in preliminary data.O objetivo deste estudo foi avaliar a performance clínica (percentagem de retenção de próteses parciais fixas reforçadas por fibras. Fibras de polietileno (Ribbond® foram usadas em combinação com resina composta durante a confecção das próteses. Os tratamentos foram realizadas em 13 pacientes, em uma clínica privada., sendo que 19 próteses foram reavaliadas. O espaço protético era preenchido com um pôntico usando o próprio dente extraído (2 casos, dentes de acrílico (11 casos ou confeccionados com resina composta (6 casos, em todas as situações eram empregadas fibras de polietileno. Os

  14. Workplace exposure to nanoparticles and the application of provisional nanoreference values in times of uncertain risks

    NARCIS (Netherlands)

    van Broekhuizen, P; van Broekhuizen, F.; Cornelissen, R.; Reijnders, L.

    2012-01-01

    Nano reference values (NRVs) for occupational use of nanomaterials were tested as provisional substitute for Occupational Exposure Limits (OELs). NRVs can be used as provisional limit values until Health-Based OELs or derived no-effect levels (DNEL) become available. NRVs were defined for 8 h

  15. Provisional Admission Practices: Blending Access and Support to Facilitate Student Success

    Science.gov (United States)

    Nichols, Andrew Howard; Clinedinst, Melissa

    2013-01-01

    This report examines provisional admission as an initiative that can expand four-year college access and success for students from economically disadvantaged backgrounds. Provisional admission policies and programs enable students to enroll at an institution under specific conditions. Students are often required to meet certain academic…

  16. 76 FR 61042 - Modification of Regulations Regarding the Practice of Accepting Bonds During the Provisional...

    Science.gov (United States)

    2011-10-03

    ... Practice of Accepting Bonds During the Provisional Measures Period in Antidumping and Countervailing Duty... importers directly responsible for the payment of AD and CVD duties. DATES: This Final Rule is effective... practice of accepting bonds during the provisional measures period in AD and CVD investigations. See...

  17. 78 FR 36571 - North American Datum of 1983 (NAD 83) Outer Continental Shelf (OCS) Provisional Official...

    Science.gov (United States)

    2013-06-18

    ... Official Protraction Diagrams in the Pacific Ocean, Hawaiian Islands Description/Date NF04-08 (Kaua'i... with this publication two NAD 83-based OCS Provisional OPDs that represent the Island of Oahu and... Title 43, Code of Federal Regulations, has created provisional versions of the basic record used for the...

  18. Early versus delayed, provisional eptifibatide in acute coronary syndromes.

    Science.gov (United States)

    Giugliano, Robert P; White, Jennifer A; Bode, Christoph; Armstrong, Paul W; Montalescot, Gilles; Lewis, Basil S; van 't Hof, Arnoud; Berdan, Lisa G; Lee, Kerry L; Strony, John T; Hildemann, Steven; Veltri, Enrico; Van de Werf, Frans; Braunwald, Eugene; Harrington, Robert A; Califf, Robert M; Newby, L Kristin

    2009-05-21

    Glycoprotein IIb/IIIa inhibitors are indicated in patients with acute coronary syndromes who are undergoing an invasive procedure. The optimal timing of the initiation of such therapy is unknown. We compared a strategy of early, routine administration of eptifibatide with delayed, provisional administration in 9492 patients who had acute coronary syndromes without ST-segment elevation and who were assigned to an invasive strategy. Patients were randomly assigned to receive either early eptifibatide (two boluses, each containing 180 microg per kilogram of body weight, administered 10 minutes apart, and a standard infusion > or = 12 hours before angiography) or a matching placebo infusion with provisional use of eptifibatide after angiography (delayed eptifibatide). The primary efficacy end point was a composite of death, myocardial infarction, recurrent ischemia requiring urgent revascularization, or the occurrence of a thrombotic complication during percutaneous coronary intervention that required bolus therapy opposite to the initial study-group assignment ("thrombotic bailout") at 96 hours. The key secondary end point was a composite of death or myocardial infarction within the first 30 days. Key safety end points were bleeding and the need for transfusion within the first 120 hours after randomization. The primary end point occurred in 9.3% of patients in the early-eptifibatide group and in 10.0% in the delayed-eptifibatide group (odds ratio, 0.92; 95% confidence interval [CI], 0.80 to 1.06; P=0.23). At 30 days, the rate of death or myocardial infarction was 11.2% in the early-eptifibatide group, as compared with 12.3% in the delayed-eptifibatide group (odds ratio, 0.89; 95% CI, 0.79 to 1.01; P=0.08). Patients in the early-eptifibatide group had significantly higher rates of bleeding and red-cell transfusion. There was no significant difference between the two groups in rates of severe bleeding or nonhemorrhagic serious adverse events. In patients who had acute

  19. VSRR - Provisional monthly and 12-month ending number of live births, deaths and infant deaths: United States

    Data.gov (United States)

    U.S. Department of Health & Human Services — https://www.cdc.gov/nchs/products/vsrr/provisional-tables.htm Monthly and 12 month-ending provisional counts of births, deaths and infant deaths are provided for the...

  20. Provisional Crown Dislodgement during Scuba Diving: A Case of Barotrauma

    Directory of Open Access Journals (Sweden)

    Meenal Nitin Gulve

    2013-01-01

    Full Text Available Changes in ambient pressure, for example, during flying, diving, or hyperbaric oxygen therapy, can lead to barotrauma. Although it may seem that this issue was neglected in dental education and research in recent decades, familiarity with and understanding of these facts may be of importance for dental practitioners. We report the case of a patient who experienced barotrauma involving dislodgement of a provisional crown during scuba diving. Patients who are exposed to pressure changes as a part of their jobs or hobbies and their dentists should know the causes of barotrauma. In addition, the clinician must be aware of the possible influence of pressure changes on the retention of dental components.

  1. Retrospective results of implants for partially edentulous posterior jaws according to time points of early loading.

    Science.gov (United States)

    Kim, Jong-Hwa; Yang, Jin-Yong; Kim, Young-Kyun; Heo, Young-Ku; Yeo, In-Sung

    2013-01-01

    This study evaluated the survival and success rates and marginal bone loss conditions of early loaded implants in the posterior maxilla and mandible of partially edentulous patients. Implants (n = 299) were placed in 105 patients at two research centers. Provisional fixed dental prostheses were provided to the patients between 1 week and 2 months after implant placement. The implants were classified into four groups according to the loading time (1 to 2, 2 to 4, 4 to 6, and 6 to 8 weeks). Periapical radiographs were taken via a parallel imaging technique, and the peri-implant marginal bone level was measured on the radiographic images. Most implants were lost within 1 month, and one implant was removed at 36 days after loading. The cumulative survival rate of the implants was 97.0%. Implants loaded in the maxilla at 1 to 2 weeks after prosthesis insertion had significantly lower survival rates than any other group (P = .013). There were no significant differences in marginal bone levels among the implant groups classified according to loading time. Early loading is a safe and predictable procedure for implant-supported restoration of posterior partial edentulism. However, care must be taken in early loading within 2 weeks after maxillary implant insertion.

  2. Immediate loading of mandibular dental implants in partially edentulous patients: a prospective randomized comparative study.

    Science.gov (United States)

    Margossian, Patrice; Mariani, Paul; Stephan, Grégory; Margerit, Jacques; Jorgensen, Christian

    2012-04-01

    While immediate loading in the edentulous mandible is a well-documented procedure, there are limited scientific data on immediate loading in the partially edentulous mandible. Two-year success rates of immediate loading and conventional delayed loading of dental implants in partially dentate mandibles were compared. Patients were randomized into three groups: group A (n = 40), immediate provisionalization with nonocclusal loading; group B (n = 40), immediate provisionalization with occlusal loading; and group C (n = 37), delayed loading with single-stage surgery. Baseline and 2-year measurements included implant stability quotient, insertion torque, and peri-implant bone crest radiography. Two hundred nine implants were immediately loaded in 80 patients. The 2-year success rates were 93.3% for group B and 100% for groups A and C. Immediate provisionalization provided success rates similar to those for delayed loading only when not loaded in occlusion.

  3. VSRR - State and National Provisional Counts for Live Births, Deaths, and Infant Deaths

    Data.gov (United States)

    U.S. Department of Health & Human Services — NOTES: Figures include all revisions received from the states and, therefore, may differ from those previously published. Data are provisional and are subject to...

  4. A provisional gene regulatory atlas for mouse heart development.

    Science.gov (United States)

    Chen, Hailin; VanBuren, Vincent

    2014-01-01

    Congenital Heart Disease (CHD) is one of the most common birth defects. Elucidating the molecular mechanisms underlying normal cardiac development is an important step towards early identification of abnormalities during the developmental program and towards the creation of early intervention strategies. We developed a novel computational strategy for leveraging high-content data sets, including a large selection of microarray data associated with mouse cardiac development, mouse genome sequence, ChIP-seq data of selected mouse transcription factors and Y2H data of mouse protein-protein interactions, to infer the active transcriptional regulatory network of mouse cardiac development. We identified phase-specific expression activity for 765 overlapping gene co-expression modules that were defined for obtained cardiac lineage microarray data. For each co-expression module, we identified the phase of cardiac development where gene expression for that module was higher than other phases. Co-expression modules were found to be consistent with biological pathway knowledge in Wikipathways, and met expectations for enrichment of pathways involved in heart lineage development. Over 359,000 transcription factor-target relationships were inferred by analyzing the promoter sequences within each gene module for overrepresentation against the JASPAR database of Transcription Factor Binding Site (TFBS) motifs. The provisional regulatory network will provide a framework of studying the genetic basis of CHD.

  5. A provisional gene regulatory atlas for mouse heart development.

    Directory of Open Access Journals (Sweden)

    Hailin Chen

    Full Text Available Congenital Heart Disease (CHD is one of the most common birth defects. Elucidating the molecular mechanisms underlying normal cardiac development is an important step towards early identification of abnormalities during the developmental program and towards the creation of early intervention strategies. We developed a novel computational strategy for leveraging high-content data sets, including a large selection of microarray data associated with mouse cardiac development, mouse genome sequence, ChIP-seq data of selected mouse transcription factors and Y2H data of mouse protein-protein interactions, to infer the active transcriptional regulatory network of mouse cardiac development. We identified phase-specific expression activity for 765 overlapping gene co-expression modules that were defined for obtained cardiac lineage microarray data. For each co-expression module, we identified the phase of cardiac development where gene expression for that module was higher than other phases. Co-expression modules were found to be consistent with biological pathway knowledge in Wikipathways, and met expectations for enrichment of pathways involved in heart lineage development. Over 359,000 transcription factor-target relationships were inferred by analyzing the promoter sequences within each gene module for overrepresentation against the JASPAR database of Transcription Factor Binding Site (TFBS motifs. The provisional regulatory network will provide a framework of studying the genetic basis of CHD.

  6. In Vitro Fit and Cementation Resistance of Provisional Crowns for Single Implant-Supported Restorations

    OpenAIRE

    Moris,Izabela Cristina Maurício; Oliveira,Juliana Elias de; Faria,Adriana Cláudia Lapria; Ribeiro,Ricardo Faria; Rodrigues,Renata Cristina Silveira

    2015-01-01

    Abstract: This study aimed to verify marginal fit and the effect of cement film thickness standardization on retention of provisional crowns made with prefabricated acrylic cylinders on abutments, using two temporary luting agents subjected or not to mechanical cycling. Provisional crowns were made from bis-acryl (Luxatemp Fluorescence) or methyl methacrylate (Duralay) resins on acrylic cylinders and marginal fit and cement film thickness were evaluated. For retention evaluation, crowns were ...

  7. Clinical evaluation of a visible light-cured indirect composite for long-term provisionalization.

    Science.gov (United States)

    Ewoldsen, Nels; Sundar, Veeraraghavan; Bennett, William; Kanya, Kevin; Magyar, Karl

    2008-01-01

    To clinically evaluate a visible light-cured (VLC) resin composite system for long-term provisional and esthetic diagnostic restorations, fabricated using indirect techniques. One-hundred and nine teeth were restored in 31 patients. Preoperational impressions were used to create VLC resin composite restorations (Radica) using indirect techniques. Restorations were relined as necessary and placed using various provisional cements at a follow-up appointment, subsequent to preparation of the teeth. Both fabricating laboratory technicians and placing dentists rated the restorations for acceptability in esthetics, marginal fit, occlusion, and functionality in various stages of provisionalization. All restorations (100%) were rated acceptable for esthetics prior to relining. After relining, a majority (93-100%) of restorations were rated acceptable in esthetic and functional criteria. At the placement of the permanent restoration, a majority (96-100%) of restorations were rated acceptable in esthetic and functional criteria. Terms of service ranged from two to seventy-six days. In combination with in vitro results, the clinical performance of the Radica VLC system for provisionalization and esthetic diagnostic restorations was judged to be acceptable. The system offers esthetics that are superior to conventional provisional restorations, and should be a valuable option to practitioners considering longer-term provisionalization in complex cases.

  8. Molecular characterization of serologically atypical provisional serovars of Shigella isolates from Kolkata, India.

    Science.gov (United States)

    Dutta, Shanta; Jain, Priyanka; Nandy, Suman; Matsushita, Shigeru; Yoshida, Shin-ichi

    2014-12-01

    During 2000-2004, 13 Shigella strains that were untypable by commercially available antisera were isolated from children Shigella dysenteriae provisional serovar 204/96 (n = 3), Shigella dysenteriae provisional serovar E23507 (n = 1), Shigella dysenteriae provisional serovar I9809-73 (n = 1), Shigella dysenteriae provisional serovar 93-119 (n = 1), Shigella flexneri provisional serovar 88-893 (n = 6) and Shigella boydii provisional serovar E16553 (n = 1). In this study, characterization of those provisional serovars of Shigella was performed with respect to their antimicrobial resistance, plasmids, virulence genes and PFGE profiles. The drug resistant strains (n = 10) of Shigella identified in this study possessed various antibiotic resistance genetic markers like catA (for chloramphenicol resistance); tetA and tetB (for tetracycline resistance); dfrA1 and sul2 (for co-trimoxazole resistance); aadA1, strA and strB (for streptomycin resistance) and blaOXA-1 (for ampicillin resistance). Class 1 and/or class 2 integrons were present in eight resistant strains. Three study strains were pan-susceptible. A single mutation in the gyrA gene (serine to leucine at codon 83) was present in four quinolone resistant strains. The virulence gene ipaH (invasion plasmid antigen H) was uniformly present in all strains in this study, but the stx (Shiga toxin) and set1 (Shigella enterotoxin 1) genes were absent. Other virulence genes like ial (invasion associated locus) and sen (Shigella enterotoxin 2) were occasionally present. A large plasmid of 212 kb and of incompatibility type IncFIIA was present in the majority of the strains (n = 10) and diversity was noticed in the smaller plasmid profiles of these strains even within the same provisional serovars. PFGE profile analysis showed the presence of multiple unrelated clones among the isolates of provisional Shigella serovars. To the best of our knowledge, this is the first report on the phenotypic and

  9. Developing a provisional and national renal disease registry for Iran

    Directory of Open Access Journals (Sweden)

    Sima Ajami

    2015-01-01

    Full Text Available Background: Disease registry is a database that includes information about people suffering a special kind of disease. The aim of this study was to first identify and compare the National Renal Disease Registry (NRDR characteristics in some countries with Iran; and second, develop a provisional and NRDR for Iran. Materials and Methods: Retrieval of data of the NRDR was performed by scholars responsible in related agencies, including the Ministry of Health and Medical Education, Renal Disease charity, and data registries in the United States, United Kingdom, Malaysia, and Iran. This research was applied, and the study was descriptive-comparative. The study population consisted of the NRDR in selected countries in which data were collected by forms that were designed according to the study objectives. Sources of data were researchers, articles, books, journals, databases, websites, related documents, and people who are active in this regard, and related agencies, including the Ministry of Health and Medical Education, and patient support charity. The researchers collected data for each country based on the study objectives and then put them in comparative tables. Data were analyzed by descriptive, comparative, and theoretical methods. Results: Most of the renal transplant teams report their own results as a single center experiences. America and Britain have a preeminent national registry of renal disease compared to other countries. Conclusion: Given that control, prevention, and treatment of chronic renal diseases incur high expenses and the disease is one of leading mortality factors in Iran and across the world and since national registry system for chronic renal diseases can provide better tools and strategies to manage and evaluate patients′ characteristics as well as risk factors which eventually leads to making better decisions.

  10. Partial priapism

    DEFF Research Database (Denmark)

    Hoyerup, Peter; Azawi, Nessn Htum

    2013-01-01

    With only 34 prior cases in world literature, partial priapism (PP), also called partial segmental thrombosis of the corpus cavernosum, is a rare urological condition. The aetiology and treatment of PP is still unclear, but bicycle riding, trauma, drug usage, sexual intercourse, haematological...

  11. A study on provisional cements, cementation techniques, and their effects on bonding of porcelain laminate veneers.

    Science.gov (United States)

    Vinod Kumar, G; Soorya Poduval, T; Bipin Reddy; Shesha Reddy, P

    2014-03-01

    Minimal tooth preparation is required for porcelain laminate veneers, but interim restorations are a must to protect their teeth against thermal insult, chemical irritation, and to provide aesthetics. Cement remaining after the removal of the provisional restoration can impair the etching quality of the tooth surface and fit and final bonding of the porcelain laminate veneer. This in vitro study examined the tooth surface for remaining debris of cement after removal of a provisional restoration. Determine the presence of cement debris on prepared tooth surface subsequent to the removal of provisional restoration. Determine the cement with the least residue following the cleansing procedures. Determine the effect of smear layer on the amount of residual luting cement. Eighty-four extracted natural anterior teeth were prepared for porcelain laminate veneers. For half of the teeth, the smear layer was removed before luting provisional restorations. Veneer provisional restorations were fabricated and luted to teeth with six bonding methods: varnish combined with glass ionomer cement (GIC), varnish combined with resin modified GIC, varnish, spot etching combined with dual-cure luting cement, adhesive combined with GIC, adhesive combined with resin modified GIC, and adhesive, spot etching combined with dual-cure luting cement. After removal of provisional restorations 1 week later, the tooth surface was examined for residual luting material with SEM. Traces of cement debris were found on all the prepared teeth surfaces for all six groups which were cemented with different methods. Cement debris was seen on teeth subsequent to the removal of provisional's. Dual-cure cement had the least residue following the cleansing procedures. Presence of smear layer had no statistical significance in comparison with cement residue. With the use of adhesive the cement debris was always found to be more than with the use of varnish. GIC showed maximum residual cement followed by dual-cure.

  12. Effect of different provisional cement remnant cleaning procedures including Er:YAG laser on shear bond strength of ceramics

    OpenAIRE

    Zortuk, Mustafa; Gumus, Hasan Onder; Kilinc, Halil Ibrahim; Tuncdemir, Ali Riza

    2012-01-01

    PURPOSE The purpose of this study was to evaluate the effect of provisional cement removal by different dentin cleaning protocols (dental explorer, pumice, cleaning bur, Er:YAG laser) on the shear bond strength between ceramic and dentin. MATERIALS AND METHODS In total, 36 caries-free unrestored human third molars were selected as tooth specimens. Provisional restorations were fabricated and cemented with eugenol-free provisional cement. Then, disc-shaped ceramic specimens were fabricated and...

  13. Análisis preliminar del Límite de Potencia Eólica para grandes perturbaciones utilizando aerogeneradores de velocidad fija; Partial analysis of wind power limit for large disturbance using fixed speed wind turbine

    Directory of Open Access Journals (Sweden)

    Ariel Santos Fuentefria

    2015-04-01

    Full Text Available El Límite de Potencia Eólica (LPE es la cantidad de potencia eólica que permite un sistema sin perder la estabilidad y depende principalmente de las características de los generadores eólicos y de las características del sistema en términos de debilidad. Conocer el comportamiento del sistema en régimen transitorio es sumamente importante; entre las condiciones que generan mayores problemas se encuentran el cortocircuito en las líneas de mayor transferencia de potenciay la salida de algún generador del sistema. El LPE cambia para cada condición y conocer el LPE considerando estas condiciones permite aprovechar al máximo la energía del viento. En el presente trabajo se analiza el comportamiento de generadores eólicos de velocidad fija para diversas condiciones transitorias de la red, utilizándose el sistema de prueba de 14 nodos de la IEEE para verificar la metodología en uso para el análisis a través de simulaciones implementadas en el software libre PSAT.  The amount of wind power that allow an electric network without losing his stability as known as wind power limit. The wind power limit fundamentally depends on the wind turbine technology and the weakness level of the system. To know the system behaviors in dynamic performance having into account the worst disturbance is a very important matter, a short circuit in one of the most power transference line or the loss of a large generation unit was a large disturbance that can affect system stability. The wind power limit may change with the nature of the disturbance. To know the wind power limit considering this conditions allow use the wind at maximum level. In the present paper the behavior of fixed speed wind turbine for different fault types is analyzed, at those conditions, the wind power is increasing until the system become voltage unstable. For the analysis the IEEE 14 Bus Test Case is used. The Power System Analysis Toolbox (PSAT package is used for the simulation.

  14. Análisis preliminar del Límite de Potencia Eólica para grandes perturbaciones utilizando aerogeneradores de velocidad fija; Partial analysis of wind power limit for large disturbance using fixed speed wind turbine

    Directory of Open Access Journals (Sweden)

    Ariel Santos Fuentefria

    2014-06-01

    Full Text Available El Límite de Potencia Eólica (LPE es la cantidad de potencia eólica que permite un sistema sin perder la estabilidad y depende principalmente de las características de los generadores eólicos y de las características del sistema en términos de debilidad. Conocer el comportamiento del sistema en régimen transitorio es sumamente importante; entre las condiciones que generan mayores problemas se encuentran el cortocircuito en las líneas de mayor transferencia de potenciay la salida de algún generador del sistema. El LPE cambia para cada condición y conocer el LPE considerando estas condiciones permite aprovechar al máximo la energía del viento. En el presente trabajo se analiza el comportamiento de generadores eólicos de velocidad fija para diversas condiciones transitorias de la red, utilizándose el sistema de prueba de 14 nodos de la IEEE para verificar la metodología en uso para el análisis a través de simulaciones implementadas en el software libre PSAT The amount of wind power that allow an electric network without losing his stability as known as wind power limit. The wind power limit fundamentally depends on the wind turbine technology and the weakness level of the system. To know the system behaviors in dynamic performance having into account the worst disturbance is a very important matter, a short circuit in one of the most power transference line or the loss of a large generation unit was a large disturbance that can affect system stability. The wind power limit may change with the nature of the disturbance. To know the wind power limit considering this conditions allow use the wind at maximum level. In the present paper the behavior of fixed speed wind turbine for different fault types is analyzed, at those conditions, the wind power is increasing until the system become voltage unstable. For the analysis the IEEE 14 Bus Test Case is used. The Power System Analysis Toolbox (PSAT package is used for the simulation.

  15. Immediate loading in partially and completely edentulous jaws: a review of the literature with clinical guidelines.

    Science.gov (United States)

    De Bruyn, Hugo; Raes, Stefanie; Ostman, Pär-Olov; Cosyn, Jan

    2014-10-01

    warranted. Immediately loaded single implants have lower survival rates, of 85.7-100%, with no clear impact of occlusal contact. In fact, a meta-analysis demonstrated a five times higher risk of failure for immediately loaded single implants when compared with delayed loading. No study showed superior soft-tissue preservation or esthetics following immediate loading of single implants compared with other loading protocols. However, this finding may not imply that a provisional implant crown becomes redundant when soft-tissue conditioning is deemed necessary. Taking into account earlier factors for success, immediate loading in the partially edentulous jaw by means of a fixed prosthesis seems predictable in terms of implant survival (95.5-100%). However, there are no studies with data on soft-tissue parameters, esthetic aspects or patient-centered outcomes, and the available studies mainly relate to the load-carrying part of the dentition. Clinical studies focusing on these aspects of treatment outcome are clearly needed. High patient satisfaction is the most important advantage of immediate loading, especially during the early healing phase. In this context, one should also realize that studies have revealed comparable patient satisfaction in patients following delayed loading once their prosthesis is in place. In the decision-making process, this aspect should be properly discussed with the patient along with other advantages and disadvantages of immediate loading. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Flexible Thermoplastic Denture Base Materials for Aesthetical Removable Partial Denture Framework

    OpenAIRE

    Singh, Kunwarjeet; Aeran, Himanshu; Kumar, Narender; Gupta, Nidhi

    2013-01-01

    Conventional fixed partial dentures, implant supported Fixed Partial Dentures (FDPs) and removable partial dentures are the most common treatment modalities for the aesthetic and functional rehabilitation of partially edentulous patients. Although implants and FDP have certain advantages over removable partial dentures, in some cases, removable partial dentures may be the only choice which is available. Removable cast partial dentures are used as definitive removable prostheses when indicated...

  17. Cell Adhesion to Acrylic Custom Provisional Abutment Placed on an Immediate Implant: A Case Report.

    Science.gov (United States)

    Saito, Hanae; Hsia, Ru-Ching; Tarnow, Dennis P; Reynolds, Mark A

    2017-02-01

    This article presents the results of a scanning electron microscope (SEM) analysis of the surface of an acrylic custom provisional abutment following first disconnection from a post-extraction immediate implant placement. An implant was placed immediately after extraction, the site was grafted, and a barrier membrane was adapted for graft containment. A custom acrylic shell was then relined, polished, and steam-cleaned prior to being screwed onto the implant. After 5 months of undisturbed healing, the custom provisional abutment was disconnected for the first time and processed for SEM examination. The surface of the custom acrylic abutment revealed well-spread fibroblast-like cells with filopodia inserting into the porous surface. These observations suggest that the surface topography of the acrylic provisional restoration/ abutment can function as a substratum for cellular adhesion and may serve an important role in supporting peri-implant mucosa at the time of immediate implant placement.

  18. Antibacterial effect of polyethyleneimine nanoparticles incorporated in provisional cements against Streptococcus mutans.

    Science.gov (United States)

    Shvero, Dana Kesler; Davidi, Michael Perez; Weiss, Ervin I; Srerer, Nir; Beyth, Nurit

    2010-08-01

    Frequently provisional restorations require long-term permanence in the oral cavity, thus an antibacterial effect is desirable. We hypothesized that this effect may be achieved by incorporating polyethyleneimine (PEI) nanoparticles into provisional cements. The nanoparticles antibacterial effect incorporated at 0.5%, 1%, and 2% w/w into provisional cement, was studied in vitro. The antibacterial effect against Streptococcus mutans and Enterococcus faecalis was tested using direct contact test. The data was analyzed using the ANOVA test, with the Dunnett test for multiple pairwise comparisons. A strong antibacterial effect was evident in all test groups after an aging period of 14 days against S. mutans and E. faecalis (p faecalis (p faecalis for a period of 14 days. The minimum effective concentration suggested is 1% w/w. Incorporation of nanoparticles may prevent caries and inflammation, and thereby improve the results of the prosthetic treatment. Further investigation is necessary on the effect on mechanical properties and clinical relevance.

  19. Microleakage of Glass Ionomer-based Provisional Cement in CAD/CAM-Fabricated Interim Crowns: An in vitro Study.

    Science.gov (United States)

    Farah, Ra'fat I; Al-Harethi, Naji

    2016-10-01

    The aim of this study was to compare in vitro the marginal microleakage of glass ionomer-based provisional cement with resin-based provisional cement and zinc oxide non-eugenol (ZONE) provisional cement in computer-aided design and computer-aided manufacturing (CAD/CAM)-fabricated interim restorations. Fifteen intact human premolars were prepared in a standardized manner for complete coverage of crown restorations. Interim crowns for the prepared teeth were then fabricated using CAD/CAM, and the specimens were randomized into three groups of provisional cementing agents (n = 5 each): Glass ionomer-based provisional cement (GC Fuji TEMP LT™), bisphenol-A-glycidyldimethacrylate (Bis-GMA)/ triethylene glycol dimethacrylate (TEGDMA) resin-based cement (UltraTemp® REZ), and ZONE cement (TempBond NE). After 24 hours of storage in distilled water at 37°C, the specimens were thermocycled and then stored again for 24 hours in distilled water at room temperature. Next, the specimens were placed in freshly prepared 2% aqueous methylene blue dye for 24 hours and then embedded in autopolymerizing acrylic resin blocks and sectioned in buccolingual and mesiodistal directions to assess dye penetration using a stereomicroscope. The results were statistically analyzed using a nonparametric Kruskal-Wallis test. Dunn's post hoc test with a Bonferroni correction test was used to compute multiple pairwise comparisons that identified differences among groups; the level of significance was set at p glass ionomer-based provisional cement and the ZONE cement. The provisional cementing agents exhibited different sealing abilities. The Bis-GMA/TEGDMA resin-based provisional cement exhibited the most effective favorable sealing properties against dye penetration compared with the glass ionomer-based provisional cement and conventional ZONE cement. Newly introduced glass ionomer-based provisional cement proved to be inferior to resin-based provisional cement as far as marginal microleakage

  20. Comparison of some properties of four provisional restorations resin: Trim, Tempron, Acropars TRII & Duralay (Aria Dent

    Directory of Open Access Journals (Sweden)

    Monzavi A.

    2006-08-01

    Full Text Available Background and Aim: Use of provisional restorations is one of the important phases in the treatment of patients who need fixed prosthesis. Some physical properties are required for these materials. The purpose of this study was the comparison of some physical properties of 4 kinds of resins: Trim, Tempron, Duralay (Aria Dent and Acropars TRII. Materials and Methods: In this experimental study, transverse-strength (TS, setting time (ST, polymerization shrinkage (PS and temperature rise (TR during polymerization were tested. In transverse strength test, 5 samples of each resin were made. TS testing was done with an Instron testing machine. ST testing (5 samples in each group was done with Gilmore needle. In PS test, 11 cylindric samples were prepared from each resin and the shrinkage was examined with digital micrometer (up to 24 hours. In TR test, after mixing the powder and liquid of resins (8 samples in each group, the temperature rise was recorded with 10 seconds interval (up to 15 minutes. Data were analyzed with one-way ANOVA and Tukey HSD tests with p<0.05 as the limit of significance. Results: In TS test, all samples of Trim were bent and no fracture was observed, while Tempron and Duralay showed no significant difference. Both Tempron and Duralay revealed high significant difference with Acropars TRII (P <0.01. In ST test, the difference between groups was significant (P<0.01. The lowest ST was observed in Acropars TRII (7 min, and the highest in Tempron (9.53 min. In PS test, significant difference was observed between Trim and Acropars TRII (P<0.01. PS was completed after 120 min in Tempron and Trim groups. However, PS continued to increase in other groups. In TR test, the difference between groups was significant (P<0.05. Duralay showed the highest TR and the lowest was seen in Trim. Conclusion: In this study, Trim showed better properties than other studied groups. Acropars TRII had the lowest strength. The highest temperature rise

  1. Myeloid Neoplasms with Germline Predisposition: A New Provisional Entity Within the World Health Organization Classification.

    Science.gov (United States)

    Czuchlewski, David R; Peterson, LoAnn C

    2016-03-01

    The forthcoming update of the World Health Organization (WHO) classification of hematopoietic neoplasms will feature "Myeloid Neoplasms with Germline Predisposition" as a new provisional diagnostic entity. This designation will be applied to some cases of acute myeloid leukemia and myelodysplastic syndrome arising in the setting of constitutional mutations that render patients susceptible to the development of myeloid malignancies. For the diagnostic pathologist, recognizing these cases and confirming the diagnosis will demand a sophisticated grasp of clinical genetics and molecular techniques. This article presents a concise review of this new provisional WHO entity, including strategies for clinical practice. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Tripled Fixed Point in Ordered Multiplicative Metric Spaces

    Directory of Open Access Journals (Sweden)

    Laishram Shanjit

    2017-06-01

    Full Text Available In this paper, we present some triple fixed point theorems in partially ordered multiplicative metric spaces depended on another function. Our results generalise the results of [6] and [5].

  3. Fracture Strength and Failure Mode of Maxillary Implant-Supported Provisional Single Crowns : A Comparison of Composite Resin Crowns Fabricated Directly Over PEEK Abutments and Solid Titanium Abutments

    NARCIS (Netherlands)

    Santing, H.J.; Meijer, Henny J.A.; Raghoebar, G.M.; Ozcan, M.

    2012-01-01

    Background: Polyetheretherketone (PEEK) temporary abutments have been recently introduced for making implant-supported provisional single crowns. Little information is available in the dental literature on the durability of provisional implant-supported restorations. Purpose: The objectives of this

  4. Esthetic Rehabilitation with a Cast Partial Denture

    Directory of Open Access Journals (Sweden)

    Suraksha Shrestha

    2017-01-01

    Full Text Available Removable partial denture is a treatment option where fixed prosthesis is not indicated. Due to its esthetic problems in the anterior region various modifications have been designed for its fabrication. This article describes an esthetic alternative using a round rest distal depression clasp for maxillary anterior teeth abutment while restoring the missing teeth with a cast partial denture.

  5. (Un)Fixing Education

    Science.gov (United States)

    Kuntz, Aaron M.; Petrovic, John E.

    2018-01-01

    In this article we consider the material dimensions of schooling as constitutive of the possibilities inherent in "fixing" education. We begin by mapping out the problem of "fixing education," pointing to the necrophilic tendencies of contemporary education--a desire to kill what otherwise might be life-giving. In this sense,…

  6. 77 FR 63801 - Aqua-Leisure Industries, Inc., Provisional Acceptance of a Settlement Agreement and Order

    Science.gov (United States)

    2012-10-17

    ... COMMISSION Aqua-Leisure Industries, Inc., Provisional Acceptance of a Settlement Agreement and Order AGENCY... Agreement with Aqua-Leisure Industries, Inc., containing a civil penalty of $650,000.00, within twenty (20... AMERICA CONSUMER PRODUCT SAFETY COMMISSION In the Matter of: Aqua-Leisure Industries, Inc. CPSC Docket No...

  7. 75 FR 1356 - RC2 Corporation, Provisional Acceptance of a Settlement Agreement and Order

    Science.gov (United States)

    2010-01-11

    ... nationwide, and secondarily through RC2's e-commerce websites or as `sub-components' of retail items... through RC2's e-commerce Web sites or as `sub-components' of retail items distributed independently of RC2... accordance with the terms of 16 CFR 1118.20(e). Published below is a provisionally-accepted Settlement...

  8. 77 FR 4023 - Hewlett-Packard Company, Provisional Acceptance of a Settlement Agreement and Order

    Science.gov (United States)

    2012-01-26

    ... COMMISSION Hewlett-Packard Company, Provisional Acceptance of a Settlement Agreement and Order AGENCY... Agreement with Hewlett-Packard Company, containing a civil penalty of $425,000.00, within twenty (20) days... 1118.20, Hewlett-Packard Company (``HP'') and the staff (``Staff'') of the United States Consumer...

  9. 75 FR 23745 - Jo-Ann Stores, Inc., Provisional Acceptance of a Settlement Agreement and Order

    Science.gov (United States)

    2010-05-04

    ... Robbie Ducky products at its retail stores nationwide during those periods for between $5 and $10 per... COMMISSION Jo-Ann Stores, Inc., Provisional Acceptance of a Settlement Agreement and Order AGENCY: Consumer... Agreement with Jo-Ann Stores, Inc., containing a civil penalty of $50,000.00. DATES: Any interested person...

  10. Effect of nightguard vital bleaching gel on the color stability of provisional restorative materials

    Directory of Open Access Journals (Sweden)

    Salwa Omar Bajunaid

    2016-01-01

    Conclusions: Composite-based provisional material showed highest color stability when exposed to vital tooth bleaching gel, whereas methacrylate-based material was the least color stable. Polycarbonate crowns were more color stable when exposed to 15% bleaching gel as opposed to 10% bleaching gel.

  11. 76 FR 49453 - CVS Pharmacy, Inc., Provisional Acceptance of a Settlement Agreement and Order

    Science.gov (United States)

    2011-08-10

    ... COMMISSION CVS Pharmacy, Inc., Provisional Acceptance of a Settlement Agreement and Order AGENCY: Consumer... Agreement with CVS Pharmacy, Inc., containing a civil penalty of $45,000.00. DATES: Any interested person... 1. In accordance with 16 CFR 1118.20, CVS Pharmacy, Inc. (``CVS'') and the U.S. Consumer Product...

  12. A provisional check list of the reptiles and amphibians of Golden Gate Highlands National Park

    Directory of Open Access Journals (Sweden)

    M.F. Bates

    1991-09-01

    Full Text Available A provisional check list of 26 reptile and amphibian species (8 frog, 8 lizard and 10 snake species occurring in Golden Gate Highlands National Park is presented. The list does not reflect the results of an intensive survey, but is a record of specimens collected in the park and preserved at the National Museum, Bloemfontein.

  13. 75 FR 26939 - Target Corporation: Provisional Acceptance of a Settlement Agreement and Order

    Science.gov (United States)

    2010-05-13

    ... settlements which it provisionally accepts under the Consumer Product Safety Act in the Federal Register in... pursuant to the Consumer Product Safety Act, 15 U.S.C. 2051-2089 (``CPSA''). The Commission is responsible...'s products consisting of the following models: Truck Carry Case; Tiny Playground Set/Dream House...

  14. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns

    Directory of Open Access Journals (Sweden)

    Adil Othman ABDULLAH

    Full Text Available ABSTRACT Objective This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. Material and Methods An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone “PEEK”, Telio CAD-Temp, and Protemp™4 (control group. The crowns were divided into four groups (n=10, Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. Results The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99 µm, PEEK 46.75 (±8.26 µm, Telio CAD-Temp 56.10 (±5.65 µm, and Protemp™4 193.07(±35.96 µm (P0.05. Conclusions CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns.

  15. NGE64/19: Regulaci??n de la jornada laboral, con car??cter provisional

    OpenAIRE

    Universidad de Granada

    2012-01-01

    Resoluci??n de la Gerencia, de 10 de septiembre de 2012, por la que se regula la jornada laboral, con car??cter provisional, para dar cumplimiento a lo establecido en la Ley 2/2012 y en el Real Decreto Ley 20/2012.

  16. 75 FR 55777 - Pro-Pac Distributing Corp., Provisional Acceptance of a Settlement Agreement and Order

    Science.gov (United States)

    2010-09-14

    ... COMMISSION Pro-Pac Distributing Corp., Provisional Acceptance of a Settlement Agreement and Order AGENCY... Agreement with Pro-Pac Distributing Corp., containing a civil penalty of $125,000.00. DATES: Any interested... STATES OF AMERICA CONSUMER PRODUCT SAFETY COMMISSION In the Matter of: Pro-Pac Distributing Corp...

  17. Partial gigantism

    Directory of Open Access Journals (Sweden)

    М.М. Karimova

    2017-05-01

    Full Text Available A girl with partial gigantism (the increased I and II fingers of the left foot is being examined. This condition is a rare and unresolved problem, as the definite reason of its development is not determined. Wait-and-see strategy is recommended, as well as correcting operations after closing of growth zones, and forming of data pool for generalization and development of schemes of drug and radial therapeutic methods.

  18. Fixed point theorems in partially ordered spaces and aplications

    OpenAIRE

    Harjani, Jackie

    2017-01-01

    [ES]Recientemente, en la Teoría del punto fijo, han aparecido muchos resultados que obtienen condiciones suficientes para la existencia de un punto fijo si trabajamos con aplicaciones en un conjunto dotado de un orden parcial. Generalmente, estos resultados combinan dos teoremas del punto fijo fundamentales: el Teorema de la contracción de Banach y el Teorema de Knaster-Tarski.

  19. Fiber-reinforced composites in fixed partial dentures

    OpenAIRE

    Garoushi, Sufyan; Vallittu, Pekka

    2006-01-01

    Fiber-reinforced composite resin (FRC) prostheses offer the advantages of good esthetics, minimal invasive treatment, and an ability to bond to the abutment teeth, thereby compensating for less-than-optimal abutment tooth retention and resistance form. These prostheses are composed of two types of composite materials: fiber composites to build the framework and hybrid or microfill particulate composites to create the external veneer surface. This review concentrates on the use of fiber reinfo...

  20. Chairside fabricated fiber-reinforced composite fixed partial denture

    Directory of Open Access Journals (Sweden)

    Sufyan Garoushi

    2007-01-01

    Full Text Available The advances in the materials and techniques for adhesive dentistry have allowed the development of non-invasive or minimally invasive approaches for replacing a missing tooth in those clinical situations when conservation of adjacent teeth is needed. Good mechanical and cosmetic/aesthetic properties of fiber-reinforced composite (FRC, with good bonding properties with composite resin cement and veneering composite are needed in FRC devices. Some recent studies have shown that adhesives of composite resins and luting cements allow diffusion of the adhesives to the FRC framework of the bridges. By this so-called interdiffusion bonding is formed [1]. FRC bridges can be made in dental laboratories or chairside. This article describes a clinical case of chairside (directly made FRC Bridge, which was used according to the principles of minimal invasive approach. Treatment was performed by Professor Vallittu from the University of Turku, Finland.

  1. Beyond the Provisional Nature: Towards a Radical Concept of Practice

    Directory of Open Access Journals (Sweden)

    Luca Verzelloni

    2016-12-01

    Full Text Available Practice is one of the key concepts of our time. During the last 30 years, the Practice-Based Studies have spread all over the world. The “rediscovery” of practice has inspired many reflections and empirical researches, contributing to the recent development of the organizational and management studies. This article aims, on the one hand, to reconstruct the debate around the concept of practice and, on the other hand, discuss its meaning, as defined within the PBS. In this paper, it will be argued that practice should be conceived as a “radical concept”. This idea, coming from the political science, is the key to explore new universes of meaning and to read and compare the practitioners' activities, the functioning of organizations and the collective learning processes. The paper will introduce the phenomenon of the so-called Observatories of Civil Justice. These interprofessional communities represent a unique window on the Italian judicial system. This case study enables to critically analyse the concept of practice and to highlight its subtypes: experimental practice, solipsistic practice, diffused practice, concerted practice, fixed practice, institutionalized practice.

  2. [Removable partial dentures. Oral functions and types].

    Science.gov (United States)

    Creugers, N H J; de Baat, C

    2009-11-01

    A removable partial denture enables the restoration or improvement of 4 oral functions: aesthetics, mandibular stability, mastication, and speech. However, wearing a removable partial denture should not cause oral comfort to deteriorate. There are 3 types of removable partial dentures: acrylic tissue-supported dentures, dentures with cast metal frameworks en dentures with cast metal frameworks and (semi)precision attachments. Interrupted tooth arches,free-ending tooth arches, and a combination of interrupted as well as free-ending tooth arches can be restored using these dentures. Well-known disadvantages of removable partial dentures are problematic oral hygiene, negative influence on the remaining dentition and limited oral comfort. Due to the advanced possibilities of fixed tooth- or implant-supported partial dentures, whether or not free-ending, or tooth- as well as implant-supported partial dentures, the indication of removable partial dentures is restricted. Nevertheless, for the time being the demand for removable partial dentures is expected to continue.

  3. Graduate Periodontics Programs' Integration of Implant Provisionalization in Core Curricula: Implementation of CODA Standard 4-10.2.d.

    Science.gov (United States)

    Barwacz, Christopher A; Pantzlaff, Ed; Allareddy, Veerasathpurush; Avila-Ortiz, Gustavo

    2017-06-01

    The aim of this descriptive study was to provide an overview of the status of implementation of Commission on Dental Accreditation (CODA) Standard 4-10.2.d (Provisionalization of Dental Implants) by U.S. graduate periodontics programs since its introduction in 2013. Surveys were sent in May 2015 to 56 accredited postdoctoral periodontics program directors to ascertain program director characteristics; status of planning, implementation, and curriculum resulting from adoption of Standard 4-10.2.d; preferred clinical protocols for implant provisionalization; interdisciplinary educational collaborators; and competency assessment mechanisms. The survey response rate was 52% (N=29); the majority were male, aged 55 or older, and had held their position for less than ten years. Among the responding programs, 93% had formal educational curricula established in implant provisionalization. Graduate periodontics (96%) and prosthodontics (63%) faculty members were predominantly involved with curriculum planning. Of these programs, 96% used immediate implant provisionalization, with direct (chairside) provisionalization protocols (86%) being preferred over indirect protocols (14%) and polyethylethylketone provisional abutments (75%) being preferred to titanium (25%) provisional abutments. Straight and concave transmucosal emergence profile designs (46% each) were preferred in teaching, with only 8% of programs favoring convex transmucosal profiles. A majority of responding programs (67%) lacked protocols for communicating to the restorative referral a mechanism to duplicate the mature peri-implant mucosal architecture. Regional location did not play a significant role in any educational component related to implant provisionalization for these graduate periodontal programs. Overall, this study found that a clear majority of graduate periodontics programs had established formal curricula related to implant provisionalization, with substantial clinical and philosophical consensus

  4. Fixed automated spray technology.

    Science.gov (United States)

    2011-04-19

    This research project evaluated the construction and performance of Boschungs Fixed Automated : Spray Technology (FAST) system. The FAST system automatically sprays de-icing material on : the bridge when icing conditions are about to occur. The FA...

  5. Fixed mobile convergence handbook

    CERN Document Server

    Ahson, Syed A

    2010-01-01

    From basic concepts to future directions, this handbook provides technical information on all aspects of fixed-mobile convergence (FMC). The book examines such topics as integrated management architecture, business trends and strategic implications for service providers, personal area networks, mobile controlled handover methods, SIP-based session mobility, and supervisory and notification aggregator service. Case studies are used to illustrate technical and systematic implementation of unified and rationalized internet access by fixed-mobile network convergence. The text examines the technolo

  6. Fixed prosthetic treatment in patients with cleft lip and palate

    Directory of Open Access Journals (Sweden)

    Bajevska Jagoda

    2017-01-01

    Full Text Available Introduction. The prosthetic treatment of patients with cleft palate includes various treatment options such as fixed partial dentures, removable partial prosthesis, etc. The type of prosthetic appliance is determined by the oral health of each individual and the circumstances. We presented three adult patients with the cleft lip and palate subjected to prosthetic treatment. Case report. From the possible prosthetic solutions according to the conditions in the oral cavity and the circumstances, fixed partial dentures veneered with composite or ceramic were chosen. A proper relationship between the teeth was reached with the fixed partial dentures, and function established, the phonetics improved and satisfying aesthetics effect accomplished improving the profile appearance of the patient’s face. Plastic surgery of the nose was performed after that. Conclusion. Multidisclipinary treatment is necessary for favourable long-term outcome in cleft lip and palate patients.

  7. Immediately loaded fixed hybrid prosthesis on a completely edentulous mandible: a case report using an indirect technique.

    Science.gov (United States)

    Small, Bruce W

    2007-11-01

    The immediate loading of implants has been a subject of controversy in the dental literature. At the same time, many patients prefer to have their teeth replaced as soon as possible without having to wear an immediate denture. Immediately loaded fixed hybrid prostheses have shown a high degree of clinical success and acceptance by patients. This article describes a case in which a provisional mandibular fixed hybrid prosthesis was placed within 24 hours of implant placement, followed by a final denture after complete osseointegration of all implants.

  8. A provisional bibliography of Asian martial arts periodicals published in Spain (1961-2009

    Directory of Open Access Journals (Sweden)

    Carlos Gutiérrez-García

    2012-07-01

    Full Text Available A provisional bibliography about Asian martial arts periodicals published in Spain from 1961, first journal’s publication date, to 2009 is presented. Asian martial arts journals were just included for preparing this bibliography. Main public documentary centres as well as personal archives were visited for information searching and data mining. Analysis process was complex due to the scarce number of this kind of publications collected in public institutions. 66 periodicals were discovered and several useful elements were detailed for their description and documentary analysis (title, type of publication, period, frequency, issues, editor, place of publication, ISSN and a brief explanation of their editorial line. Despite its provisional character, this bibliography shows the great amount and variety of data contained in these periodicals, turning into a relevant resource for studying the martial arts’ history in Spain.

  9. An Investigation Into the Integrity of Fit of Provisional Crowns Using Current Proprietary Temporary Crown Materials.

    Science.gov (United States)

    Taylor, Philip D; Georgakis, Georgios; Niggli, Jason

    2016-06-01

    Three methods of direct provisional crown construction were investigated for accuracy of marginal fit. A modified proprietary crown coping was compared to Bis GMA and isobutyl methacrylate resin provisional crowns with margins modified by using a flowable composite and 'bead on' isobutyl methacrylate respectively. Measurement was at 50x magnification at seven sites over the fit surface. Data was analyzed using SPSS version 13.0.1 and measurement compared using the Mann Whitney test set at a significance level of 0.05. Reliability was checked using the Bland Altman test. Statistical significant differences were found between the three groups. The order of best fit was Bis-GMA and flowable composite > isobutyl methacrylate with 'bead on' margins > Bis-GMA modified implant temporary coping. The clinical significance is that the Bis GMA and flowable composite combination can be used with equal confidence to traditional methods of temporarisation.

  10. The Paediatric Rheumatology International Trials Organisation provisional criteria for the evaluation of response to therapy in juvenile dermatomyositis

    DEFF Research Database (Denmark)

    Ruperto, Nicolino; Pistorio, Angela; Ravelli, Angelo

    2010-01-01

    To develop a provisional definition for the evaluation of response to therapy in juvenile dermatomyositis (DM) based on the Paediatric Rheumatology International Trials Organisation juvenile DM core set of variables....

  11. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns.

    Science.gov (United States)

    Abdullah, Adil Othman; Tsitrou, Effrosyni A; Pollington, Sarah

    2016-01-01

    This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone "PEEK", Telio CAD-Temp, and Protemp™4 (control group). The crowns were divided into four groups (n=10), Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99) µm, PEEK 46.75 (±8.26) µm, Telio CAD-Temp 56.10 (±5.65) µm, and Protemp™4 193.07(±35.96) µm (PCAD-Temp® 124.94 (±22.96) µm, PEEK 113.14 (±23.55) µm, Telio CAD-Temp 110.95 (±11.64) µm, and Protemp™4 143.48(±26.74) µm. The average fracture strength was: VITA CAD-Temp® 361.01 (±21.61) N, PEEK 802.23 (±111.29) N, Telio CAD-Temp 719.24 (±95.17) N, and Protemp™4 416.40 (±69.14) N. One-way ANOVA test showed a statistically significant difference for marginal gap, internal gap, and fracture strength between all groups (p0.05). CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns.

  12. Immediate provisional restoration of a single-tooth implant in the esthetic zone: A case report

    OpenAIRE

    Fu, Po-Sung; Wu, Yi-Min; Tsai, Ching-Fang; Huang, Ta-Ko; Chen, Wen-Cheng; Hung, Chun-Cheng; 傅柏松,; 吳逸民,; 蔡菁芳,; 黃大可; 陳文正,; 洪純正,

    2011-01-01

    Immediate implant restoration of single implants may demonstrate a positive effect on peri-implant soft tissue. Placement of a provisional restoration following implant surgery can create soft tissue contours that resemble normal gingival topography before placement of the definitive prosthesis. This article describes a staged approach of the mandibular permanent right central incisor, which was congenital missing. The proper space for restoration of the missing incisor was created through or...

  13. Biomechanical impact of provisional stenting and balloon dilatation on coronary bifurcation: clinical implications.

    Science.gov (United States)

    Chen, Henry Y; Al-Saadon, Khalid; Louvard, Yves; Kassab, Ghassan S

    2017-07-01

    In-stent restenosis (ISR) and stent thrombosis remain clinically significant problems for bifurcations. Although the role of wall shear stress (WSS) has been well investigated, the role of circumferential wall stresses (CWS) has not been well studied in provisional stenting with and without final kissing balloon (FKB). We hypothesized that the perturbation of CWS at the SB in provisional stenting and balloon dilatation is an important factor in addition to WSS, and, hence, may affect restenosis rates (i.e., higher CWS correlates with higher restenosis). To test this hypothesis, we developed computational models of stent, FKB at bifurcation, and finite element simulations that considered both fluid and solid mechanics of the vessel wall. We computed the stress ratio (CWS/WSS) to show potential correlation with restenosis in clinical studies (i.e., higher stress ratio correlates with higher restenosis). Our simulation results show that stenting in the main branch (MB) increases the maximum CWS in the side branch (SB) and, hence, yields a higher stress ratio in the SB, as compared with the MB. FKB dilatation decreases the CWS and increases WSS, which collectively lowers the stress ratio in the SB. The changes of stress ratio were correlated positively with clinical data in provisional stenting and FKB. Both fluid and solid mechanics need to be evaluated when considering various stenting techniques at bifurcations, as solid stresses also play an important role in clinical outcome. An integrative index of bifurcation mechanics is the stress ratio that considers both CWS and WSS.NEW & NOTEWORTHY Although the role of wall shear stress (WSS) has been well investigated, the role of circumferential wall stresses (CWS) has not been well studied in provisional stenting with and without final kissing balloon. Both fluid and solid mechanics need to be evaluated when considering various stenting techniques at bifurcations. An integrative index of bifurcation mechanics is the

  14. Provisional in-silico biopharmaceutics classification (BCS) to guide oral drug product development

    OpenAIRE

    Wolk O; Agbaria R; Dahan A

    2014-01-01

    Omri Wolk, Riad Agbaria, Arik Dahan Department of Clinical Pharmacology, School of Pharmacy, Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva, Israel Abstract: The main objective of this work was to investigate in-silico predictions of physicochemical properties, in order to guide oral drug development by provisional biopharmaceutics classification system (BCS). Four in-silico methods were used to estimate LogP: group contribution (CLogP) using two different softwa...

  15. Examining the provisional guidelines for weight gain in twin pregnancies: a retrospective cohort study

    OpenAIRE

    Lutsiv, Olha; Hulman, Adam; Woolcott, Christy; Beyene, Joseph; Giglia, Lucy; Armson, B. Anthony; Dodds, Linda; Neupane, Binod; McDonald, Sarah D

    2017-01-01

    Background Weight gain during pregnancy has an important impact on maternal and neonatal health. Unlike the Institute of Medicine (IOM) recommendations for weight gain in singleton pregnancies, those for twin gestations are termed “provisional”, as they are based on limited data. The objectives of this study were to determine the neonatal and maternal outcomes associated with gaining weight below, within and above the IOM provisional guidelines on gestational weight gain in twin pregnancies, ...

  16. The American Volunteer Soldier: Will He Fight. (A Provisional Attitudinal Analysis)

    Science.gov (United States)

    1975-06-02

    NUMBER 4. TITLE (end Subtitlm) THE AMERICAN VOLUNTEER SOLDIER: WILL HE FIGHT? (A PROVISIONAL ATTITUDINAL ANALYSIS) 5. TYPE OF REPORT A PERIOD... Psychologycal Solutions to Social Problems; An Introduction to Social Technology. New York: Academic Press, 1971. Walton, George, COL, USA (Ret...QUESTIONNAIRE. There are several types of questions in this questionnaire. EXAMPLES of the types you will encounter are listed below: FILL IN: [EXAMPLE

  17. Influence of immediate loading on provisional restoration in dental implant stability

    Science.gov (United States)

    Ikbal, M.; Odang, R. W.; Indrasari, M.; Dewi, R. S.

    2017-08-01

    The success of dental implant treatment is determined by the primary stability at placement. One factor that could influence this stability is occlusal loading through provisional restoration. Two types of loading protocols are usually used: immediate and delayed loading. However, some controversies remain about the influence of occlusal loading on implant stability. Therefore, the influence of immediate loading on implant stability must be studied. An animal study was conducted by placing nine dental implants in the mandibular jaw of three Macaca fascicularis. Provisional restorations with various occlusal contacts (no, light, and normal contact) were placed on the implant. The implant stability was measured using the Ostell ISQ three times: immediately (baseline) and at the first and second months after implant placement. The implant stability between implants with no and normal occlusal contact as well as light and normal occlusal contact showed significant differences (p implant placement. However, no significant increase (p > 0.05) in implant stability was seen at the baseline and the first and second months after implant placement for all occlusal contact groups. Immediate loading influenced the implant stability, and provisional restoration of implant without occlusal contact showed the highest implant stability.

  18. Fixed point theory in metric type spaces

    CERN Document Server

    Agarwal, Ravi P; O’Regan, Donal; Roldán-López-de-Hierro, Antonio Francisco

    2015-01-01

    Written by a team of leading experts in the field, this volume presents a self-contained account of the theory, techniques and results in metric type spaces (in particular in G-metric spaces); that is, the text approaches this important area of fixed point analysis beginning from the basic ideas of metric space topology. The text is structured so that it leads the reader from preliminaries and historical notes on metric spaces (in particular G-metric spaces) and on mappings, to Banach type contraction theorems in metric type spaces, fixed point theory in partially ordered G-metric spaces, fixed point theory for expansive mappings in metric type spaces, generalizations, present results and techniques in a very general abstract setting and framework. Fixed point theory is one of the major research areas in nonlinear analysis. This is partly due to the fact that in many real world problems fixed point theory is the basic mathematical tool used to establish the existence of solutions to problems which arise natur...

  19. Fixing Dataset Search

    Science.gov (United States)

    Lynnes, Chris

    2014-01-01

    Three current search engines are queried for ozone data at the GES DISC. The results range from sub-optimal to counter-intuitive. We propose a method to fix dataset search by implementing a robust relevancy ranking scheme. The relevancy ranking scheme is based on several heuristics culled from more than 20 years of helping users select datasets.

  20. Immediately loaded mandibular fixed implant prostheses using the all-on-four protocol: a report of 183 consecutively treated patients with 1 year of function in definitive prostheses.

    Science.gov (United States)

    Galindo, Daniel F; Butura, Caesar C

    2012-01-01

    The purpose of this study was to evaluate a specific protocol using four implants to support immediately loaded fixed prostheses to restore edentulous and partially edentulous mandibles and report on the outcome after 1 year of function with the definitive prostheses. A retrospective study was conducted of all patients who were treated between June 2008 and December 2010 with fixed prostheses that were loaded immediately after placement of implants. The provisional prostheses were later replaced with computer-aided design/computer-assisted manufacture titanium frames supporting acrylic resin and denture teeth in the definitive prosthesis. All patients were followed for a minimum of 12 months and were assessed for implant survival and prosthetic performance, with descriptive statistics utilized to demonstrate results. One hundred eighty-three consecutive patients received immediately loaded axial and tilted implants according to the defined protocol. One implant failed, resulting in a 99.86% implant success rate. There were two catastrophic prosthetic failures (fracture of the titanium framework), for a 98.9% prosthetic success rate. Three patients (1.6%) presented with fracture of a prosthetic mandibular incisor tooth. No prosthetic screw loosening or fractures were seen. Radiographic evaluation revealed no major bone loss around dental implants. Based on this retrospective study, the following conclusions can be drawn: (1) this technique appears to provide a highly predictable implant performance; (2) it is necessary to critically evaluate framework design, especially around the connectors for cantilever extensions around the most distal implants; and (3) minor complications related to acrylic resin tooth fracture may be anticipated during the early phases of prosthetic treatment.

  1. Computer-assisted virtual treatment planning combined with flapless surgery and immediate loading in the rehabilitation of partial edentulies.

    Science.gov (United States)

    DE Vico, G; Spinelli, D; Bonino, M; Schiavetti, R; Pozzi, A; Ottria, L

    2012-01-01

    It has been suggested that for success with immediate loaded dental implants it is necessary that, prior to their placement, bone quality and quantity as well as the biomechanical environment in which the implants are to function be evaluated.However, conventional techniques currently used for immediate implant placement lack sufficient precision and are usually accomplished by opening flap procedures. Nowadays computer-guided flapless surgery for implant placement using stereolithographic templates is gaining popularity among clinicians and patients. The advantages of this surgical protocol are its minimally invasive nature, accuracy of implant placement, predictability, less post-surgical disconfort and reduced time required for definitive rehabilitation. The introduction of digital planning programs has made it possible to place dental implants in preplanned positions and being immediately functionally loaded by using prefabricated prostheses. The surgical guide is used, infact, to develop a master model and fabricate the provisional bridge that will be secured to the implants immediately after their placement using the guided surgery template. In this way patients are able to achieve, in the same day of the surgery, a comfortable fixed rehabilitation needing only minor occlusal adjustments. Job S. et al during the three-month period, have demonstrated that the average reduction of crestal bone height around the implants placed with flapless surgery (0.06 mm) is not statistically significant, while the average reduction of crestal bone height around the implants placed using flap surgery (0.4 mm) is statistically significant, concluding that the use of stereolithographic appliances in accordance with flapless surgery makes immediate placement of the implants more predictable. However, the documentation of this technique in partial rehabilitations is limited. PURPOSE of this paper is to report the benefit of sophisticated pre-operative diagnostic implant planning

  2. the Fixed Point Consideration

    Directory of Open Access Journals (Sweden)

    Penumurthy Parvateesam Murthy

    2013-01-01

    Full Text Available A fixed point theorem is presented for single-valued map with using generalized φ-weak contractive condition involving various combinations of dx,y on a complete metric space. Our result is an extension as well as a generalization of Alber and Guerre-Delabriere (1997 in particular. It also generalizes the results of Rhoades (2001, Choudhury and Dutta, (2000, and Dutta and Choudhury, (2008.

  3. Comparison of the color stability of provisional restorative materials after storing in different drinks

    Directory of Open Access Journals (Sweden)

    Merve Bankoğlu Güngör

    2016-05-01

    Full Text Available OBJECTIVE: The objective of the present study was to compare the color stability of provisional restorative materials after stroring in different drinks. MATERIALS AND METHOD: Thirty specimens (10 mm in diameter and 2 mm in thickness were prepared from three different materials (Temdent, TRIAD ve TelioCAD. Specimens were divided into six groups according to drinks (distilled water, coffee, tea, cola, red wine and fruit juice; n=5. Specimens were stored in these drinks at 37 °C for 48 hours. The L*, a*, b* values of the specimens were measured with a spectrophometer and recorded before and after storing in drinks. Then ΔE* values were calculated. The data were statistically analyzed using two-way analysis of variance (ANOVA and Tukey’s HSD post hoc tests (α=0.05. RESULTS: Difference between the ΔE* values of specimens stored in different drinks was statistically significant (p<0.05. Color change of TelioCAD specimens was smallest in cola drink and greatest in red wine. Color change of Temdent specimens was smallest in fruit juice and greatest in coffee. For TRIAD specimens, greater color change was observed in coffee, red wine, and tea, in descending order. When the results of storing in the same drink were compared, TRIAD showed the greatest values of color change in coffee and red wine in comparison to the other provisional materials (p<0.05. CONCLUSION: Color stability changed according to the type of the provisional material and the drink. When the drinks were evaluated, greater color changes were observed in coffee, and when the materials were evaluated greater color changes were observed in TRIAD.

  4. Effect of different provisional cement remnant cleaning procedures including Er:YAG laser on shear bond strength of ceramics.

    Science.gov (United States)

    Zortuk, Mustafa; Gumus, Hasan Onder; Kilinc, Halil Ibrahim; Tuncdemir, Ali Riza

    2012-11-01

    The purpose of this study was to evaluate the effect of provisional cement removal by different dentin cleaning protocols (dental explorer, pumice, cleaning bur, Er:YAG laser) on the shear bond strength between ceramic and dentin. In total, 36 caries-free unrestored human third molars were selected as tooth specimens. Provisional restorations were fabricated and cemented with eugenol-free provisional cement. Then, disc-shaped ceramic specimens were fabricated and randomly assigned to four groups of dentin cleaning protocols (n = 9). Group 1 (control): Provisional cements were mechanically removed with a dental explorer. Group 2: The dentin surfaces were treated with a cleaning brush with pumice Group 3: The dentin surfaces were treated with a cleaning bur. Group 4: The provisional cements were removed by an Er:YAG laser. Self-adhesive luting cement was used to bond ceramic discs to dentin surfaces. Shear bond strength (SBS) was measured using a universal testing machine at a 0.05 mm/min crosshead speed. The data were analyzed using a Kolmogorov Smirnov, One-way ANOVA and Tukey HSD tests to perform multiple comparisons (α=0.05). THE DENTIN CLEANING METHODS DID NOT SIGNIFICANTLY AFFECT THE SBS OF CERAMIC DISCS TO DENTIN AS FOLLOWS: dental explorer, pumice, cleaning bur, and Er:YAG laser. The use of different cleaning protocols did not affect the SBS between dentin and ceramic surfaces.

  5. Effect of different provisional cement remnant cleaning procedures including Er:YAG laser on shear bond strength of ceramics

    Science.gov (United States)

    Zortuk, Mustafa; Gumus, Hasan Onder; Kilinc, Halil Ibrahim

    2012-01-01

    PURPOSE The purpose of this study was to evaluate the effect of provisional cement removal by different dentin cleaning protocols (dental explorer, pumice, cleaning bur, Er:YAG laser) on the shear bond strength between ceramic and dentin. MATERIALS AND METHODS In total, 36 caries-free unrestored human third molars were selected as tooth specimens. Provisional restorations were fabricated and cemented with eugenol-free provisional cement. Then, disc-shaped ceramic specimens were fabricated and randomly assigned to four groups of dentin cleaning protocols (n = 9). Group 1 (control): Provisional cements were mechanically removed with a dental explorer. Group 2: The dentin surfaces were treated with a cleaning brush with pumice Group 3: The dentin surfaces were treated with a cleaning bur. Group 4: The provisional cements were removed by an Er:YAG laser. Self-adhesive luting cement was used to bond ceramic discs to dentin surfaces. Shear bond strength (SBS) was measured using a universal testing machine at a 0.05 mm/min crosshead speed. The data were analyzed using a Kolmogorov Smirnov, One-way ANOVA and Tukey HSD tests to perform multiple comparisons (α=0.05). RESULTS The dentin cleaning methods did not significantly affect the SBS of ceramic discs to dentin as follows: dental explorer, pumice, cleaning bur, and Er:YAG laser. CONCLUSION The use of different cleaning protocols did not affect the SBS between dentin and ceramic surfaces. PMID:23236570

  6. Matkowski's type theorems for generalized contractions on (ordered partial metric spaces

    Directory of Open Access Journals (Sweden)

    Salvador Romaguera

    2011-10-01

    Full Text Available We obtain extensions of Matkowski's fixed point theorem for generalized contractions of Ciric's type on 0-complete partial metric spaces and on ordered 0-complete partial metric spaces, respectively.

  7. Fixed solar energy concentrator

    Energy Technology Data Exchange (ETDEWEB)

    Houghton, A.J.; Knasel, T.M.

    1981-01-20

    An apparatus for the concentration of solar energy upon a fixed array of solar cells is disclosed. A transparent material is overlayed upon the cell array, and a diffuse reflective coating is applied to the surface area of the transparent medium in between cells. Radiant light, which reflects through the transparent layer and does not fall directly incident to a cell surface is reflected by the coating layer in an approximate cosine pattern. Thereafter, such light undergoes internal reflection and rediffusion until subsequently it either strikes a solar cell surface or is lost through the upper surface of the transparent material.

  8. Digital fixed points, approximate fixed points, and universal functions

    Directory of Open Access Journals (Sweden)

    Laurence Boxer

    2016-10-01

    Full Text Available A. Rosenfeld [23] introduced the notion of a digitally continuous function between digital images, and showed that although digital images need not have fixed point properties analogous to those of the Euclidean spaces modeled by the images, there often are approximate fixed point properties of such images. In the current paper, we obtain additional results concerning fixed points and approximate fixed points of digitally continuous functions. Among these are several results concerning the relationship between universal functions and the approximate fixed point property (AFPP.

  9. Fixed target beams

    CERN Document Server

    Kain, V; Cettour-Cave, S; Cornelis, K; Fraser, M A; Gatignon, L; Goddard, B; Velotti, F

    2017-01-01

    The CERN SPS (Super Proton Synchrotron) serves asLHC injector and provides beam for the North Area fixedtarget experiments. At low energy, the vertical acceptancebecomes critical with high intensity large emittance fixed tar-get beams. Optimizing the vertical available aperture is a keyingredient to optimize transmission and reduce activationaround the ring. During the 2016 run a tool was developed toprovide an automated local aperture scan around the entirering.The flux of particles slow extracted with the1/3inte-ger resonance from the Super Proton Synchrotron at CERNshould ideally be constant over the length of the extractionplateau, for optimum use of the beam by the fixed target ex-periments in the North Area. The extracted intensity is con-trolled in feed-forward correction of the horizontal tune viathe main SPS quadrupoles. The Mains power supply noiseat 50 Hz and harmonics is also corrected in feed-forwardby small amplitude tune modulation at the respective fre-quencies with a dedicated additional quad...

  10. Immediate implant placement and provisionalization with simultaneous guided bone regeneration in the esthetic zone

    Directory of Open Access Journals (Sweden)

    Chih-Long Chen

    2011-03-01

    Full Text Available The procedure for immediate implant placement and provisionalization is time-saving, possibly with only one surgical intervention required, although allowing maximal preservation of peri-implant tissues. In this case, we extracted a fractured maxillary right central incisor of a 46-year-old woman with high esthetic expectations, and a transmucosal implant was immediately installed. Simultaneous guided bone regeneration was performed to correct the defects at the facial side of the socket and augment the alveolar ridge horizontally. Primary stability of the implant body and wound closure without tension were confirmed. Connection of a 15° angled abutment and fabrication of a provisional acrylic resin crown without occlusal contact were also completed in the same appointment. After intensive follow-up and soft-tissue molding for 6 months, the customized zirconia abutment and all-ceramic crown were definitively fabricated. During the 18-month follow-up period, the patient was satisfied with the esthetic and functional results.

  11. Comparative evaluation of marginal leakage of provisional crowns cemented with different temporary luting cements: In vitro study

    Science.gov (United States)

    Arora, Sheen Juneja; Arora, Aman; Upadhyaya, Viram; Jain, Shilpi

    2016-01-01

    Background or Statement of Problem: As, the longevity of provisional restorations is related to, a perfect adaptation and a strong, long-term union between restoration and teeth structures, therefore, evaluation of marginal leakage of provisional restorative materials luted with cements using the standardized procedures is essential. Aims and Objectives: To compare the marginal leakage of the provisional crowns fabricated from Autopolymerizing acrylic resin crowns and bisphenol A-glycidyl dimethacrylate (BIS-GMA) resin crowns. To compare the marginal leakage of the provisional crowns fabricated from autopolymerizing acrylic resin crowns and BIS-GMA resin crowns cemented with different temporary luting cements. To compare the marginal leakage of the provisional crowns fabricated from autopolymerizing acrylic resin (SC-10) crowns cemented with different temporary luting cements. To compare the marginal leakage of the provisional crowns fabricated from BIS-GMA resin crowns (Protemp 4) cemented with different temporary luting cements. Methodology: Freshly extracted 60 maxillary premolars of approximately similar dimensions were mounted in dental plaster. Tooth reduction with shoulder margin was planned to use a customized handpiece-holding jig. Provisional crowns were prepared using the wax pattern fabricated from computer aided designing/computer aided manufacturing milling machine following the tooth preparation. Sixty provisional crowns were made, thirty each of SC-10 and Protemp 4 and were then cemented with three different luting cements. Specimens were thermocycled, submerged in a 2% methylene blue solution, then sectioned and observed under a stereomicroscope for the evaluation of marginal microleakage. A five-level scale was used to score dye penetration in the tooth/cement interface and the results of this study was analyzed using the Chi-square test, Mann–Whitney U-test, Kruskal–Wallis H-test and the results were statistically significant P crowns

  12. Fixed Access Network Sharing

    Science.gov (United States)

    Cornaglia, Bruno; Young, Gavin; Marchetta, Antonio

    2015-12-01

    Fixed broadband network deployments are moving inexorably to the use of Next Generation Access (NGA) technologies and architectures. These NGA deployments involve building fiber infrastructure increasingly closer to the customer in order to increase the proportion of fiber on the customer's access connection (Fibre-To-The-Home/Building/Door/Cabinet… i.e. FTTx). This increases the speed of services that can be sold and will be increasingly required to meet the demands of new generations of video services as we evolve from HDTV to "Ultra-HD TV" with 4k and 8k lines of video resolution. However, building fiber access networks is a costly endeavor. It requires significant capital in order to cover any significant geographic coverage. Hence many companies are forming partnerships and joint-ventures in order to share the NGA network construction costs. One form of such a partnership involves two companies agreeing to each build to cover a certain geographic area and then "cross-selling" NGA products to each other in order to access customers within their partner's footprint (NGA coverage area). This is tantamount to a bi-lateral wholesale partnership. The concept of Fixed Access Network Sharing (FANS) is to address the possibility of sharing infrastructure with a high degree of flexibility for all network operators involved. By providing greater configuration control over the NGA network infrastructure, the service provider has a greater ability to define the network and hence to define their product capabilities at the active layer. This gives the service provider partners greater product development autonomy plus the ability to differentiate from each other at the active network layer.

  13. Common fixed points of single-valued and multivalued maps

    Directory of Open Access Journals (Sweden)

    Yicheng Liu

    2005-01-01

    Full Text Available We define a new property which contains the property (EA for a hybrid pair of single- and multivalued maps and give some new common fixed point theorems under hybrid contractive conditions. Our results extend previous ones. As an application, we give a partial answer to the problem raised by Singh and Mishra.

  14. Solution of fractional differential equations via coupled fixed point

    Directory of Open Access Journals (Sweden)

    Hojjat Afshari

    2015-11-01

    Full Text Available In this article, we investigate the existence and uniqueness of a solution for the fractional differential equation by introducing some new coupled fixed point theorems for the class of mixed monotone operators with perturbations in the context of partially ordered complete metric space.

  15. Comparison of fixed versus variable biofuels incentives

    Energy Technology Data Exchange (ETDEWEB)

    Tyner, Wallace E.; Taheripour, Farzad; Perkis, David [Department of Agricultural Economics, Purdue University, West Lafayette, IN 47907 (United States)

    2010-10-15

    We evaluated several variants of a variable biofuel subsidy and compared them with the fixed subsidy and Renewable Fuel Standard using two different modeling approaches. First we used a partial equilibrium model encompassing crude oil, gasoline, ethanol, corn, and ethanol by-products. Second, we used a stochastic simulation model of a prototypical ethanol plant. From the partial equilibrium analysis, it appears the variable subsidy provides a safety net for ethanol producers when oil prices are low; yet, it does not put undue pressure on corn prices when oil prices are high. At high oil prices, the level of ethanol production is driven by market forces. From the plant level stochastic analysis, essentially the same conclusions are reached. As with the fixed subsidy, the variable subsidy can increase the net present value (NPV) sufficiently to encourage investment, but with lower risk for the producer, lower probability of a loss from the investment, and often lower expected cost to government. Finally, in the US, the ethanol industry is up against a blending limit called the blend wall. If the blending wall remains in place and no way around it is found, it does not matter much what other policy options are used. (author)

  16. [Fiber-reinforced composite in fixed prosthodontics].

    Science.gov (United States)

    Pilo, R; Abu Rass, Z; Shmidt, A

    2010-07-01

    Fiber reinforced composite (FRC) is composed of resin matrix and fibers filler. Common types of fibers: polyethylene, carbon and glass. Fibers can be continuous and aligned, discontinuous and aligned, discontinuous and randomly oriented. The architecture of the fibers is unidirectional, woven or braided. The two main types are: dry fibers or impregnated. Inclusion of fibers to resin composite increased its average flexural strength in 100-200 MPa. FRC can be utilized by the dentist in direct approach (splinting, temporary winged bridge) or indirect approach (laboratory made fixed partial denture). Laboratory fixed partial denture (FPD) is made from FRC substructure and Hybrid/Microfill particulate composite veneer. Main indications: interim temporary FPD or FPD in cases of questionable abutment teeth, in aesthetic cases where All Ceram FPD is not feasible. Retention is attained by adhesive cementation to minimally prepared teeth or to conventionally prepared teeth; other options are inlay-onlay bridges or hybrid bridges. Contraindications are: poor hygiene, inability to control humidity, parafunction habits, and more than two pontics. Survival rate of FRC FPD over 5 years is 75%, lower compared to porcelain fused to metal FPD which is 95%. Main reasons for failure are: fracture of framework and delamination of the veneer. Part of the failures is repairable.

  17. Student (Mis)application of Partial Differentiation to Material Properties

    Science.gov (United States)

    Bucy, Brandon R.; Thompson, John R.; Mountcastle, Donald B.

    2007-01-01

    Students in upper-level undergraduate thermodynamics courses were asked about the relationship between the complementary partial derivatives of the isothermal compressibility and the thermal expansivity of a substance. Both these material properties can be expressed with first partial derivatives of the system volume. Several of the responses implied difficulty with the notion of variables held fixed in a partial derivative. Specifically, when asked to find the partial derivative of one of these quantities with respect to a variable that was initially held fixed, a common response was that this (mixed second) partial derivative must be zero. We have previously reported other related difficulties in the context of the Maxwell relations, indicating persistent confusion applying partial differentiation to state functions. We present results from student homework and examination questions and briefly discuss an instructional strategy to address these issues.

  18. An early loaded implant-supported mandibular complete arch fixed prosthesis in a young completely edentulous patient: a case report.

    Science.gov (United States)

    Mathew, Miriam; John, Bobby; George, Arun

    2013-08-01

    The restoration of the mandibular arch up to the first molars with 5 one-piece implants presents a viable and cost-effective treatment plan in patients with adequate bone volume and favorable ridge relationships. The early loading of the implants with a provisional restoration reduces the period of edentulousness and restores the patient's ability to eat, talk, and smile effectively. Implants in younger patients prevent resorption of the residual alveolar ridge. This article presents a case report of the restoration of an edentulous mandibular arch with an early loaded implant-supported fixed restoration in a young patient.

  19. 78 FR 3883 - The Bon-Ton Stores, Inc., Provisional Acceptance of a Settlement Agreement and Order

    Science.gov (United States)

    2013-01-17

    ... drawstrings (Garments) to consumers. The Garments were sold at retail stores in the United States for between... COMMISSION The Bon-Ton Stores, Inc., Provisional Acceptance of a Settlement Agreement and Order AGENCY... Agreement with The Bon-Ton Stores, Inc., containing a civil penalty of $450,000.00, within twenty (20) days...

  20. 76 FR 77981 - Build-A-Bear Workshop, Inc., Provisional Acceptance of a Settlement Agreement and Order

    Science.gov (United States)

    2011-12-15

    ... COMMISSION Build-A-Bear Workshop, Inc., Provisional Acceptance of a Settlement Agreement and Order AGENCY... Agreement with Build-A-Bear Workshop, Inc., containing a civil penalty of $600,000.00. DATES: Any interested... Agreement 1. In accordance with 16 CFR 1118.20, Build-A-Bear Workshop, Inc. (``Build-A-Bear'') and staff of...

  1. Immediate loading versus immediate provisionalization of maxillary single-tooth replacements: a prospective randomized study with BioComp implants

    NARCIS (Netherlands)

    Lindeboom, Jerome A.; Frenken, Joost W.; Dubois, Leander; Frank, Michael; Abbink, Ingmar; Kroon, Frans H.

    2006-01-01

    PURPOSE: The aim of this prospective randomized study was to evaluate the clinical outcome of immediately loaded solid plasma sprayed (TPS) BioComp (BioComp Industries BV, Vught, The Netherlands) implants versus immediate provisionalized but non-loaded BioComp implants in the anterior and premolar

  2. Investigation on the hematopoietic effect of functional foods using radiation and preparing the provisional product

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Ho; Oh, Heon; Lee, Song Eun; Jeong, Yong Woon [Chonnam National University, Kwangju (Korea)

    1999-04-01

    We performed this study to determine the effect of several oriental prescriptions as energy tonic (Chinese medical concept: Bu-Qi) or blood building (Chinese medical concept: Bu-Xie) decoction and its major ingredients on jejunal crypt survival, endogenous spleen colony formation, and apoptosis in jejunal crypt cells of mice irradiated with high and low dose of gamma-irradiation. For the study of evaluation on the biological stability of irradiated chinese medical prescriptions, we performed the experiment to determine the effect of irradiated (10kGy) or unirradiated Si-Wu-Tang, Bu-Zhong-Yi-Qi-Tang and San-Ling-Bai-Shu-San in irradiated mice. Further studies are needed to characterize better the protective nature of the total extract and its ingredients and for preparing the provisional product. (author). 61 refs., 3 figs., 21 tabs.

  3. Retentive force of O-ring attachment to use Immediate Provisional Implant (IPI)-retained overdenture.

    Science.gov (United States)

    Kobayashi, Mariko; Ohkubo, Chikahiro; Suzuki, Yasunori; Aoki, Takayuki; Sato, Jun-ichi; Hosoi, Toshio

    2005-12-01

    This study evaluated the retentive force of the O-ring attachment to an Immediate Provisional Implant (IPI)-retained overdenture. Two sizes of O-rings (#1, #2) were placed on the IPI abutment head. As the controls, soft relining material, silicone lining material, and the PMMA resin were used to connect the IPI abutment head. The retentive forces (n=5, N) obtained at a crosshead speed of 40 mm/min were analyzed by ANOVA/Tukey's HSD test (alpha=0.05). O-ring #1 showed the significantly greatest force among all materials tested (p0.05). Appropriate retention was obtained using the smaller O-ring#1 for the IPI-retained overdenture.

  4. Upper lower Cambrian (provisional Cambrian Series 2 trilobites from northwestern Gansu Province, China

    Directory of Open Access Journals (Sweden)

    Jan Bergström†

    2014-08-01

    Full Text Available Upper lower Cambrian (provisional Cambrian Series 2 trilobites are described from three sections through the Shuangyingshan Formation in the Beishan area, northwestern Gansu Province, China. The trilobite fauna is dominated by eodiscoid and corynexochid trilobites, together representing at least ten genera: Serrodiscus, Tannudiscus, Calodiscus, Pagetides, Kootenia, Edelsteinaspis, Ptarmiganoides?, Politinella, Dinesus and Subeia. Eleven species are described, of which seven are identified with previously described taxa and four described under open nomenclature. The composition of the fauna suggests biogeographic affinity with Siberian rather than Gondwanan trilobite faunas, and the Cambrian Series 2 faunas described herein and from elsewhere in northwestern China seem to be indicative of the marginal areas of the Siberian palaeocontinent. This suggests that the Middle Tianshan–Beishan Terrane may have been located fairly close to Siberia during middle–late Cambrian Epoch 2.

  5. Pre-surgical Provisional Prosthesis for Immediate Non-occlusal-loaded Flapless Implant.

    Science.gov (United States)

    Inbarajan, Athiban; Banu, Fathima; Tv, Padmanabhan; Kumar, Anand; Seenivasan, Madhan

    2017-06-13

    A 49-year-old patient reported for immediate replacement of missing maxillary anterior teeth with implant-retained prosthesis. Elevation of flap alters the mucosal level, causes discomfort, and delays the restorative procedure. To maintain the esthetics, flapless surgery was planned. Since placement of an implant is pre-planned in a predetermined site, fabrication of the prostheses before commencement of the surgery, especially when replacing the teeth in the anterior region, could be a viable option. This case report explains the method of fabrication of the provisional restoration for flapless surgery in the presurgical phase. The technique would avoid any micromotion and implant instability caused due to abutment preparation and impression procedure postsurgically.

  6. Pre-prosthetic minor tooth movement with elastic separating ring & provisional restoration modification: case report

    Directory of Open Access Journals (Sweden)

    Haneol Shin

    2012-05-01

    Full Text Available Proximal caries or coronal defect in posterior teeth may result in the loss of proximal space and drifting of neighboring teeth, which makes restoration difficult. Inability to restore proper contours and to align tooth axis properly are commonly encountered problems when planning tooth restoration. Moreover, tilted teeth aggravate periodontal tissue breakdown, such as pseudo-pocket, and angular osseous defect. The purpose of this case presentation is to describe a simple technique for inducing minor tooth movement with orthodontic separating ring and provisional restoration modification. This method was used to create crown placement space on mesially tilted molar. This method is easy, simple and efficient technique which could be used in interproximal space gaining in selected situation.

  7. Workplace exposure to nanoparticles and the application of provisional nanoreference values in times of uncertain risks

    Science.gov (United States)

    van Broekhuizen, Pieter; van Broekhuizen, Fleur; Cornelissen, Ralf; Reijnders, Lucas

    2012-03-01

    Nano reference values (NRVs) for occupational use of nanomaterials were tested as provisional substitute for Occupational Exposure Limits (OELs). NRVs can be used as provisional limit values until Health-Based OELs or derived no-effect levels (DNEL) become available. NRVs were defined for 8 h periods (time weighted average) and for short-term exposure periods (15 min-time weighted average). To assess the usefulness of these NRVs, airborne number concentrations of nanoparticles (NPs) in the workplace environment were measured during paint manufacturing, electroplating, light equipment manufacturing, non-reflective glass production, production of pigment concentrates and car refinishing. Activities monitored were handling of solid engineered NPs (ENP), abrasion, spraying and heating during occupational use of nanomaterials (containing ENPs) and machining nanosurfaces. The measured concentrations are often presumed to contain ENPs as well as process-generated NPs (PGNP). The PGNP are found to be a significant source for potential exposure and cannot be ignored in risk assessment. Levels of NPs identified in workplace air were up to several millions of nanoparticles/cm3. Conventional components in paint manufacturing like CaCO3 and talc may contain a substantial amount of nanosized particulates giving rise to airborne nanoparticle concentrations. It is argued that risk assessments carried out for e.g. paint manufacturing processes using conventional non-nano components should take into account potential nanoparticle emissions as well. The concentrations measured were compared with particle-based NRVs and with mass-based values that have also been proposed for workers protection. It is concluded that NRVs can be used for risk management for handling or processing of nanomaterials at workplaces provided that the scope of NRVs is not limited to ENPs only, but extended to the exposure to process-generated NPs as well.

  8. In Vitro Fit and Cementation Resistance of Provisional Crowns for Single Implant-Supported Restorations.

    Science.gov (United States)

    Moris, Izabela Cristina Maurício; Oliveira, Juliana Elias de; Faria, Adriana Cláudia Lapria; Ribeiro, Ricardo Faria; Rodrigues, Renata Cristina Silveira

    2015-10-01

    This study aimed to verify marginal fit and the effect of cement film thickness standardization on retention of provisional crowns made with prefabricated acrylic cylinders on abutments, using two temporary luting agents subjected or not to mechanical cycling. Provisional crowns were made from bis-acryl (Luxatemp Fluorescence) or methyl methacrylate (Duralay) resins on acrylic cylinders and marginal fit and cement film thickness were evaluated. For retention evaluation, crowns were cemented with two temporary luting agents: non-eugenol zinc oxide (Tempbond NE) or calcium hydroxide-based (Hydcal) cements and subjected to tensile strength in a universal testing machine. After cleaning, debonded crowns were cemented again, subjected to mechanical cycling and retention was reassessed. The results of marginal fit and cement film thickness were analyzed by Student's t-test while retention of cements before and after mechanical cycling was analyzed using a mixed linear model. Methyl methacrylate crowns presented greater marginal misfit (p=0.001) and occlusal cement film thickness (p=0.003) than the bis-acryl ones. No difference was observed at axial cement film thickness (p=0.606). Resins (p=0.281) did not affect crown retention, but luting agents (p=0.029) and mechanical cycling (p=0.027) showed significant effects. The only significant interaction was mechanical cycling*luting agents, which means that luting agents were differently affected by mechanical cycling (p=0.002). In conclusion, the results showed that bis-acryl resin associated to calcium-hydroxide luting agent provided the best retention and lower cement thickness.

  9. Agitation in cognitive disorders: International Psychogeriatric Association provisional consensus clinical and research definition.

    Science.gov (United States)

    Cummings, Jeffrey; Mintzer, Jacobo; Brodaty, Henry; Sano, Mary; Banerjee, Sube; Devanand, D P; Gauthier, Serge; Howard, Robert; Lanctôt, Krista; Lyketsos, Constantine G; Peskind, Elaine; Porsteinsson, Anton P; Reich, Edgardo; Sampaio, Cristina; Steffens, David; Wortmann, Marc; Zhong, Kate

    2015-01-01

    Agitation is common across neuropsychiatric disorders and contributes to disability, institutionalization, and diminished quality of life for patients and their caregivers. There is no consensus definition of agitation and no widespread agreement on what elements should be included in the syndrome. The International Psychogeriatric Association formed an Agitation Definition Work Group (ADWG) to develop a provisional consensus definition of agitation in patients with cognitive disorders that can be applied in epidemiologic, non-interventional clinical, pharmacologic, non-pharmacologic interventional, and neurobiological studies. A consensus definition will facilitate communication and cross-study comparison and may have regulatory applications in drug development programs. The ADWG developed a transparent process using a combination of electronic, face-to-face, and survey-based strategies to develop a consensus based on agreement of a majority of participants. Nine-hundred twenty-eight respondents participated in the different phases of the process. Agitation was defined broadly as: (1) occurring in patients with a cognitive impairment or dementia syndrome; (2) exhibiting behavior consistent with emotional distress; (3) manifesting excessive motor activity, verbal aggression, or physical aggression; and (4) evidencing behaviors that cause excess disability and are not solely attributable to another disorder (psychiatric, medical, or substance-related). A majority of the respondents rated all surveyed elements of the definition as "strongly agree" or "somewhat agree" (68-88% across elements). A majority of the respondents agreed that the definition is appropriate for clinical and research applications. A provisional consensus definition of agitation has been developed. This definition can be used to advance interventional and non-interventional research of agitation in patients with cognitive impairment.

  10. Immediate loading of maxillary prostheses using flapless surgery, implant placement in predetermined positions, and prefabricated provisional restorations. Part 2: a retrospective 10-year clinical study.

    Science.gov (United States)

    Rocci, Antonio; Rocci, Marta; Scoccia, Andrea; Martignoni, Massimiliano; Gottlow, Jan; Sennerby, Lars

    2012-01-01

    Immediate loading has become a widely reported practice in implant dentistry. The aim of this study is to report on the 10-year clinical and radiographic outcomes of an immediate-loading treatment protocol that included flapless surgery. Forty-six patients were treated with 97 immediately loaded Mk IV implants (Nobel Biocare) with machined surface in the maxilla. Presurgically, a three-dimensional model of each patient's soft tissue and underlying alveolar bone anatomy was created and a surgical template was fabricated. A circular mucotome was used to punch out a 5-mm hole in the mucosa to avoid flap elevation. Control examinations were performed on the day of surgery and at 1, 2, 3, 6, 8, and 10 years after surgery. All prepared implant sites had intact buccal and lingual bone walls. The prefabricated provisional restorations showed excellent fit. Nine implants failed within 8 weeks of loading, resulting in a cumulative survival rate of 91% after 10 years of loading. The survival rates were 94% for implants supporting partial prostheses and 81% for implants supporting single restorations. Average marginal bone resorption was 1 mm during the first year, 0.4 mm during the second year, and 0.1 mm during the third year and after 10 years. The unchanged survival rate and the low average bone loss after 10 years confirm the feasibility of an immediate loading treatment protocol in the maxilla that included flapless surgery.

  11. Weather Impact on Airport Arrival Meter Fix Throughput

    Science.gov (United States)

    Wang, Yao

    2017-01-01

    Time-based flow management provides arrival aircraft schedules based on arrival airport conditions, airport capacity, required spacing, and weather conditions. In order to meet a scheduled time at which arrival aircraft can cross an airport arrival meter fix prior to entering the airport terminal airspace, air traffic controllers make regulations on air traffic. Severe weather may create an airport arrival bottleneck if one or more of airport arrival meter fixes are partially or completely blocked by the weather and the arrival demand has not been reduced accordingly. Under these conditions, aircraft are frequently being put in holding patterns until they can be rerouted. A model that predicts the weather impacted meter fix throughput may help air traffic controllers direct arrival flows into the airport more efficiently, minimizing arrival meter fix congestion. This paper presents an analysis of air traffic flows across arrival meter fixes at the Newark Liberty International Airport (EWR). Several scenarios of weather impacted EWR arrival fix flows are described. Furthermore, multiple linear regression and regression tree ensemble learning approaches for translating multiple sector Weather Impacted Traffic Indexes (WITI) to EWR arrival meter fix throughputs are examined. These weather translation models are developed and validated using the EWR arrival flight and weather data for the period of April-September in 2014. This study also compares the performance of the regression tree ensemble with traditional multiple linear regression models for estimating the weather impacted throughputs at each of the EWR arrival meter fixes. For all meter fixes investigated, the results from the regression tree ensemble weather translation models show a stronger correlation between model outputs and observed meter fix throughputs than that produced from multiple linear regression method.

  12. Reinforcement of a PMMA resin for interim fixed prostheses with silica nanoparticles.

    Science.gov (United States)

    Topouzi, Marianthi; Kontonasaki, Eleana; Bikiaris, Dimitrios; Papadopoulou, Lambrini; Paraskevopoulos, Konstantinos M; Koidis, Petros

    2017-05-01

    Fractures in long span provisional/interim restorations are a common complication. Adequate fracture toughness is necessary to resist occlusal forces and crack propagation, so these restorations should be constructed with materials of improved mechanical properties. The aim of this study was to investigate the possible reinforcement of neat silica nanoparticles and trietoxyvinylsilane-modified silica nanoparticles in a PMMA resin for fixed interim restorations. Composite PMMA-Silica nanoparticles powders were mixed with PMMA liquid and compact bar shaped specimens were fabricated according to the British standard BS EN ISO 127337:2005. The single-edge notched method was used to evaluate fracture toughness (three-point bending test), while the dynamic thermomechanical properties (Storage Modulus, Loss Modulus, tanδ) of a series of nanocomposites with different amounts of nanoparticles (0.25%, 0.50%, 0.75%, 1% w.t.) were evaluated. Statistical analysis was performed and the statistically significant level was set to pnanoparticles. Dynamic mechanical properties were also affected. By increasing the silica nanoparticles content an increase in Storage Modulus was recorded, while Glass Transition Temperature was shifted at higher temperatures. Under the limitations of this in-vitro study, it can be suggested that both neat silica nanoparticles and trietoxyvinylsilane-modified silica nanoparticles, especially at low concentrations, may enhance the overall performance of fixed interim prostheses, as can effectively increase the fracture toughness, the elastic modulus and the Glass Transition Temperature of PMMA resins used in fixed provisional restorations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Flat coalgebraic fixed point logics

    NARCIS (Netherlands)

    Schröder, L.; Venema, Y.

    2010-01-01

    Fixed point logics are widely used in computer science, in particular in artificial intelligence and concurrency. The most expressive logics of this type are the μ-calculus and its relatives. However, popular fixed point logics tend to trade expressivity for simplicity and readability, and in fact

  14. Flexible thermoplastic denture base materials for aesthetical removable partial denture framework.

    Science.gov (United States)

    Singh, Kunwarjeet; Aeran, Himanshu; Kumar, Narender; Gupta, Nidhi

    2013-10-01

    Conventional fixed partial dentures, implant supported Fixed Partial Dentures (FDPs) and removable partial dentures are the most common treatment modalities for the aesthetic and functional rehabilitation of partially edentulous patients. Although implants and FDP have certain advantages over removable partial dentures, in some cases, removable partial dentures may be the only choice which is available. Removable cast partial dentures are used as definitive removable prostheses when indicated, but location of clasps may affect aesthetics. So, when patient is concerned about aesthetics, flexible partial dentures which is aesthetically superior to flipper and cast partial dentures, may be considered. But for the success of flexible removable partial denture, proper diagnosis, treatment planning and insertion technique of this prosthesis is very important, which have been thoroughly described in this article.

  15. Partial tooth gear bearings

    Science.gov (United States)

    Vranish, John M. (Inventor)

    2010-01-01

    A partial gear bearing including an upper half, comprising peak partial teeth, and a lower, or bottom, half, comprising valley partial teeth. The upper half also has an integrated roller section between each of the peak partial teeth with a radius equal to the gear pitch radius of the radially outwardly extending peak partial teeth. Conversely, the lower half has an integrated roller section between each of the valley half teeth with a radius also equal to the gear pitch radius of the peak partial teeth. The valley partial teeth extend radially inwardly from its roller section. The peak and valley partial teeth are exactly out of phase with each other, as are the roller sections of the upper and lower halves. Essentially, the end roller bearing of the typical gear bearing has been integrated into the normal gear tooth pattern.

  16. Partial Pole Placement in LMI Region

    Directory of Open Access Journals (Sweden)

    Liuli Ou

    2014-01-01

    Full Text Available A new approach for pole placement of single-input system is proposed in this paper. Noncritical closed loop poles can be placed arbitrarily in a specified convex region when dominant poles are fixed in anticipant locations. The convex region is expressed in the form of linear matrix inequality (LMI, with which the partial pole placement problem can be solved via convex optimization tools. The validity and applicability of this approach are illustrated by two examples.

  17. Removable partial dentures: use of rapid prototyping.

    Science.gov (United States)

    Lima, Julia Magalhaes Costa; Anami, Lilian Costa; Araujo, Rodrigo Maximo; Pavanelli, Carlos A

    2014-10-01

    The CAD/CAM technology associated with rapid prototyping (RP) is already widely used in the fabrication of all-ceramic fixed prostheses and in the biomedical area; however, the use of this technology for the manufacture of metal frames for removable dentures is new. This work reports the results of a literature review conducted on the use of CAD/CAM and RP in the manufacture of removable partial dentures. © 2014 by the American College of Prosthodontists.

  18. Fixed points of periodic maps.

    Science.gov (United States)

    Cappell, S E; Shaneson, J L

    1980-09-01

    Let f be a periodic differentiable map from a sphere to itself. A well-known conjecture of Smith asserts that in many cases (e.g., when the fixed points are isolated) the derivatives of f at its fixed points, regarded as Jacobian matrices, are linearly similar. Here we give counterexamples to this conjecture. The results show that, in many cases, these Jacobian matrices are only nonlinearly similar. This uses our recent discovery of orthogonal matrices which are nonlinearly similar without being linearly similar. Some results on general smooth actions of finite groups on differentiable manifolds are presented; the topological equivalence of their tangential representations at the fixed points is studied.

  19. A cross-validation of the provisional diagnostic instrument (PDI-4

    Directory of Open Access Journals (Sweden)

    Faries Douglas E

    2012-10-01

    Full Text Available Abstract Background The Provisional Diagnostic Instrument (PDI-4 is a brief, adult self-report instrument for 4 common psychiatric diagnoses in primary care patients: major depressive episode (MDE, generalized anxiety disorder (GAD, attention deficit hyperactivity disorder (ADHD, and bipolar I disorder based on past or present mania. Our objective was to assess validity of the PDI-4 in a population independent of the study population originally used to develop the scale. Methods An online version of the 17-item PDI-4 was administered to 1,047 adults in the US; respondents also completed the PHQ-9, HADS-A, CAARS-S, and MDQ within the online survey. Respondents self-reported diagnosis by a healthcare professional with the terms depression (n=221, anxiety (n=218, attention deficit disorder (n=206, bipolar or manic depressive disorder (n=195, or none of these (n=207. Statistical analyses examined convergent and discriminant validity, and operating characteristics of the PDI-4 relative to the individual, validated, self-rated scales PHQ-9, HADS-A, CAARS-S, and MDQ, for each PDI-4 diagnosis. Results Convergent validity of the PDI-4 was supported by strong correlations with the corresponding individual scales (range of 0.63 [PDI-4 and MDQ] to 0.87 [PDI-4 and PHQ-9]. Operating characteristics of the PDI-4 were similar to results in the previous site-based study. The scale exhibited moderate sensitivities (0.52 [mania] to 0.70 [ADHD] and strong specificities (0.86 [mania] to 0.92 [GAD] using the individual scales as the gold standards. ANOVAs demonstrated that PDI-4 discriminated between subsets of patients defined by pre-specified severity level cutoff scores of the individual scales. However, overlapping symptoms and co-morbidities made differentiation between mental diagnoses much weaker than differentiation from the control group with none of the diagnoses. Conclusions The PDI-4 appears to be a suitable, brief, self-rated tool for provisional

  20. Physiologically-based pharmacokinetic model for Fentanyl in support of the development of Provisional Advisory Levels

    Energy Technology Data Exchange (ETDEWEB)

    Shankaran, Harish, E-mail: harish.shankaran@pnnl.gov [Computational Biology and Bioinformatics Group, Pacific Northwest National Laboratory, Richland, WA 99352 (United States); Adeshina, Femi [National Homeland Security Research Center, United States Environmental Protection Agency, Washington, DC 20460 (United States); Teeguarden, Justin G. [Systems Toxicology Group, Pacific Northwest National Laboratory, Richland, WA 99352 (United States)

    2013-12-15

    Provisional Advisory Levels (PALs) are tiered exposure limits for toxic chemicals in air and drinking water that are developed to assist in emergency responses. Physiologically-based pharmacokinetic (PBPK) modeling can support this process by enabling extrapolations across doses, and exposure routes, thereby addressing gaps in the available toxicity data. Here, we describe the development of a PBPK model for Fentanyl – a synthetic opioid used clinically for pain management – to support the establishment of PALs. Starting from an existing model for intravenous Fentanyl, we first optimized distribution and clearance parameters using several additional IV datasets. We then calibrated the model using pharmacokinetic data for various formulations, and determined the absorbed fraction, F, and time taken for the absorbed amount to reach 90% of its final value, t90. For aerosolized pulmonary Fentanyl, F = 1 and t90 < 1 min indicating complete and rapid absorption. The F value ranged from 0.35 to 0.74 for oral and various transmucosal routes. Oral Fentanyl was absorbed the slowest (t90 ∼ 300 min); the absorption of intranasal Fentanyl was relatively rapid (t90 ∼ 20–40 min); and the various oral transmucosal routes had intermediate absorption rates (t90 ∼ 160–300 min). Based on these results, for inhalation exposures, we assumed that all of the Fentanyl inhaled from the air during each breath directly, and instantaneously enters the arterial circulation. We present model predictions of Fentanyl blood concentrations in oral and inhalation scenarios relevant for PAL development, and provide an analytical expression that can be used to extrapolate between oral and inhalation routes for the derivation of PALs. - Highlights: • We develop a Fentanyl PBPK model for relating external dose to internal levels. • We calibrate the model to oral and inhalation exposures using > 50 human datasets. • Model predictions are in good agreement with the available

  1. Examining the provisional guidelines for weight gain in twin pregnancies: a retrospective cohort study.

    Science.gov (United States)

    Lutsiv, Olha; Hulman, Adam; Woolcott, Christy; Beyene, Joseph; Giglia, Lucy; Armson, B Anthony; Dodds, Linda; Neupane, Binod; McDonald, Sarah D

    2017-09-29

    Weight gain during pregnancy has an important impact on maternal and neonatal health. Unlike the Institute of Medicine (IOM) recommendations for weight gain in singleton pregnancies, those for twin gestations are termed "provisional", as they are based on limited data. The objectives of this study were to determine the neonatal and maternal outcomes associated with gaining weight below, within and above the IOM provisional guidelines on gestational weight gain in twin pregnancies, and additionally, to explore ranges of gestational weight gain among women who delivered twins at the recommended gestational age and birth weight, and those who did not. A retrospective cohort study of women who gave birth to twins at ≥20 weeks gestation, with a birth weight ≥ 500 g was conducted in Nova Scotia, Canada (2003-2014). Our primary outcome of interest was small for gestational age (<10th percentile). In order to account for gestational age at delivery, weekly rates of 2nd and 3rd trimester weight gain were used to categorize women as gaining below, within, or above guidelines. We performed traditional regression analyses for maternal outcomes, and to account for the correlated nature of the neonatal outcomes in twins, we used generalized estimating equations (GEE). A total of 1482 twins and 741 mothers were included, of whom 27%, 43%, and 30% gained below, within, and above guidelines, respectively. The incidence of small for gestational age in these three groups was 30%, 21%, and 20%, respectively, and relative to gaining within guidelines, the adjusted odds ratios were 1.44 (95% CI 1.01-2.06) for gaining below and 0.92 (95% CI 0.62-1.36) for gaining above. The gestational weight gain in women who delivered twins at 37-42 weeks with average birth weight ≥ 2500 g and those who delivered twins outside of the recommend ranges were comparable to each other and the IOM recommendations. While gestational weight gain below guidelines for twins was associated with some

  2. Reestablishing aesthetic and function of patient with severe worn dentition: a conservative approach with provisional fixed tooth/implant supported prosthesis

    National Research Council Canada - National Science Library

    Guilherme Gonçalves Andreatta; Fernanda Durski Teixeira; Leonardo Fernandes Cunha; Adilson Yoshio Furuse; Gisele Maria Correr Nolasco; Carlos Eduardo E Rezende

    2015-01-01

    ...: To report a clinical case of restoration of masticatory function and aesthetics from the production of tooth/implant-supported prostheses with conservative preparations, reestablishing the OVD and occlusal stability. Case report...

  3. Fixed Points of Geraghty-Type Mappings in Various Generalized Metric Spaces

    Directory of Open Access Journals (Sweden)

    Dušan Ðukić

    2011-01-01

    Full Text Available Fixed point theorems for mappings satisfying Geraghty-type contractive conditions are proved in the frame of partial metric spaces, ordered partial metric spaces, and metric-type spaces. Examples are given showing that these results are proper extensions of the existing ones.

  4. National Radiological Fixed Lab Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — The National Radiological Fixed Laboratory Data Asset includes data produced in support of various clients such as other EPA offices, EPA Regional programs, DOE,...

  5. Elevated Fixed Platform Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Elevated Fixed Platform (EFP) is a helicopter recovery test facility located at Lakehurst, NJ. It consists of a 60 by 85 foot steel and concrete deck built atop...

  6. Can Interagency Cooperation Be Fixed?

    National Research Council Canada - National Science Library

    Vavasseur, Jana A

    2007-01-01

    ...) in order to figure out the root of our failures and fix it. That introspection has drawn many academics, politicians and military officers alike to examine interagency coordination for a solution...

  7. Multifactorial analysis of variables influencing the fracture strength of repair joints for provisional restorative materials using the statistically based Taguchi method

    Directory of Open Access Journals (Sweden)

    Chun-Jen Cheng

    2010-06-01

    Conclusion: Within the limitations of this study, these four design factors had different contributions to the fracture strength of repaired provisional restorations. Clinicians must be aware of the sequence of importance in determining better problem-solving methods.

  8. Effect of water temperature on the fit of provisional crown margins during polymerization: An in vitro study

    Science.gov (United States)

    Ramkumar, Vivekanandan; Sangeetha, Arunachalam; Kumar, Vinaya

    2012-01-01

    Aim: To evaluate the effect of water temperature on the marginal fit of bis-acrylic composite provisional crown during resin polymerization. Materials and Methods: Precisely machined 10 brass master dies were designed to simulate molar teeth. Five brass dies were selected and precisely machined to simulate all ceramic crown preparation. An acrylic jaw replica was made in which brass dies were arranged equidistant from each other. A custom-made metallic tray was fabricated on the acrylic jaw replica to make polyvinyl siloxane impression matrix. Bis-acrylic composite resin provisional crowns were made using polyvinyl siloxane impression matrix. Provisional crowns were polymerized at room temperature (Group I direct technique, on dental stone cast; Group I indirect technique crowns) and at different water temperatures (Group II direct technique crowns). The vertical marginal gap between all the provisional crown margins and the finish line of brass dies was measured using a Research Stereomicroscope System. Results: The results were statistically analyzed using one-way analysis of variance (ANOVA) test and Newman–Keul's test. The results showed that crowns polymerized in 20°C and 30°C water had marginal gap approximately three times smaller than those polymerized in 30°C air, due to the reduced polymerization shrinkage. Conclusion: This study shows that crowns polymerized in 20°C and 30°C water had mean vertical marginal gap approximately three times smaller than those polymerized in 30°C air. It was approximately closer to that of crowns fabricated by indirect technique. Warmer water also supposedly hastens polymerization. PMID:23066294

  9. Coronal leakage of provisional restorative materials used in endodontics with and without intracanal medication after exposure to human saliva

    Directory of Open Access Journals (Sweden)

    P Udayakumar

    2016-01-01

    Full Text Available Aim: To determine the coronal leakage of various provisional restorations with and without intracanal medication over time after being exposed to human saliva. Materials and Methods: This study investigated Coltosol F, Cavit, Ketac Molar, and IRM as provisional restorative material. Calcium hydroxide and chlorhexidine were used as an intracanal medicament. Ninety-eight single rooted teeth were randomly selected and then mounted in an apparatus that isolated the crown portion of the tooth. Provisional restorative materials were placed in the access cavity following manufacturer guidelines after placement of intracanal medicament. Human saliva and brain heart infusion broth in 3:1 ratio were applied to the samples, incubated at 37°C, and results were tabulated over the course of 4 weeks by the appearance of turbidity in the lower part of the apparatus. Statistical Analysis: The data were statistically analyzed using proportional Z-test. The level of significance was set at 0.05. Results: Coltosol F and Cavit could significantly prevent the bacterial leakage up to a period of 7 days with a P value of 0.01 and 0.005, respectively. Bacterial recontamination was relatively less in the samples treated with intracanal medicaments up to 14 days. After 14 days, however, all materials leaked in over half of the samples. Conclusion: No provisional restorative material can be considered superior in providing a reliable seal after 14 days. Inter-appointments schedule should not extend beyond 2 weeks and after endodontic therapy final restoration should be completed within 1 week.

  10. Randomized comparison between provisional and routine kissing-balloon technique after main vessel crossover stenting for coronary bifurcation lesions.

    Science.gov (United States)

    Yamawaki, Masahiro; Fujita, Masaki; Sasaki, Shinya; Tsurugida, Masanori; Nanasato, Mamoru; Araki, Motoharu; Hirano, Keisuke; Ito, Yoshiaki; Tsukahara, Reiko; Muramatsu, Toshiya

    2017-04-11

    We compared the myocardial ischemic burden of provisional and routine final kissing-balloon inflation (FKI) with the 1-stent strategy using a second-generation drug-eluting stent for coronary bifurcation lesions (CBL). There are no established guidelines for side branch (SB) intervention after main vessel stenting. In total, 113 CBL patients were randomized to receive different SB intervention strategies: provisional-FKI group (n = 57; FKI only when SB flow was TIMI stress myocardial perfusion scintigraphy with (99m)Tc was performed after 8 months. The regional summed-difference score (r-SDS) was calculated according to the coronary territory. The primary endpoint included target vessel ischemia (TVI; r-SDS ≥ 2) at 8 months, whereas the clinical primary endpoint was major adverse cardiovascular events (MACE) at 3 years. The percent (%) myocardial ischemia (100 × SDS/68) was also calculated. At 8 months, TVI was identified in 11 and 4% in the provisional-FKI and routine-FKI groups, respectively (p = 0.226). SB-binary restenosis (48 vs. 4%, p 10% myocardial ischemia) was not observed in the target vessel in either group. Long-term cumulative MACE were similar between the groups (9 vs. 14%; p = 0.358). Provisional-FKI according to TIMI-SB flow grade led to similar and acceptable myocardial ischemia, in comparison with routine-FKI, which may contribute to the identical long-term follow-up.

  11. Effect of water temperature on the fit of provisional crown margins during polymerization: An in vitro study

    Directory of Open Access Journals (Sweden)

    Vivekanandan Ramkumar

    2012-01-01

    Full Text Available Aim: To evaluate the effect of water temperature on the marginal fit of bis-acrylic composite provisional crown during resin polymerization. Materials and Methods: Precisely machined 10 brass master dies were designed to simulate molar teeth. Five brass dies were selected and precisely machined to simulate all ceramic crown preparation. An acrylic jaw replica was made in which brass dies were arranged equidistant from each other. A custom-made metallic tray was fabricated on the acrylic jaw replica to make polyvinyl siloxane impression matrix. Bis-acrylic composite resin provisional crowns were made using polyvinyl siloxane impression matrix. Provisional crowns were polymerized at room temperature (Group I direct technique, on dental stone cast; Group I indirect technique crowns and at different water temperatures (Group II direct technique crowns. The vertical marginal gap between all the provisional crown margins and the finish line of brass dies was measured using a Research Stereomicroscope System. Results: The results were statistically analyzed using one-way analysis of variance (ANOVA test and Newman-Keul′s test. The results showed that crowns polymerized in 20°C and 30°C water had marginal gap approximately three times smaller than those polymerized in 30°C air, due to the reduced polymerization shrinkage. Conclusion: This study shows that crowns polymerized in 20°C and 30°C water had mean vertical marginal gap approximately three times smaller than those polymerized in 30°C air. It was approximately closer to that of crowns fabricated by indirect technique. Warmer water also supposedly hastens polymerization.

  12. Provisional Tic Disorder: What to tell parents when their child first starts ticcing

    Science.gov (United States)

    Black, Kevin J; Black, Elizabeth Rose; Greene, Deanna J.; Schlaggar, Bradley L.

    2016-01-01

    The child with recent onset of tics is a common patient in a pediatrics or child neurology practice. If the child’s first tic was less than a year in the past, the diagnosis is usually Provisional Tic Disorder (PTD). Published reviews by experts reveal substantial consensus on prognosis in this situation: the tics will almost always disappear in a few months, having remained mild while they lasted. Surprisingly, however, the sparse existing data may not support these opinions. PTD may have just as much importance for science as for clinical care. It provides an opportunity to prospectively observe the spontaneous remission of tics. Such prospective studies may aid identification of genes or biomarkers specifically associated with remission rather than onset of tics. A better understanding of tic remission may also suggest novel treatment strategies for Tourette syndrome, or may lead to secondary prevention of tic disorders. This review summarizes the limited existing data on the epidemiology, phenomenology, and outcome of PTD, highlights areas in which prospective study is sorely needed, and proposes that tic disorders may completely remit much less often than is generally believed. PMID:27158458

  13. Soft Tissue Augmentation Techniques in Implants Placed and Provisionalized Immediately: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Rosa Rojo

    2016-01-01

    Full Text Available The aim of this study was to evaluate the effectiveness of techniques for soft tissue augmentation in the placement of immediate implants with and without provisionalization and to assess the quality of the reports in the literature. Randomized clinical trials, prospective clinical trials, and case series were included in this review. Clinical questions were formulated and organised according to the PICOS strategy. An electronic search was performed in PubMed, Cochrane Central Register of Controlled Trials, Scopus, and ISI Web up until June 2016. Interexaminer agreement on eligibility (k=0.842; p=0.103 and quality (k=0.933; p<0.001 was high. Methodological approaches were assessed using criteria based on design related forms designed by the Dutch Cochrane Collaboration. Finally, 14 papers were identified. In two studies, the implant survival was 90%; for the rest of the studies it was 100%. All studies reported favourable aesthetic, biological, and radiographic outcomes. Surgical and biomechanical complications of this technique were not relevant. This technique effectively compensates for the expected loss of volume of the oral soft tissues and maintains high success rates with good aesthetic results over time.

  14. Provisional Matrix Deposition in Hemostasis and Venous Insufficiency: Tissue Preconditioning for Nonhealing Venous Ulcers

    Science.gov (United States)

    Parker, Tony J.; Broadbent, James A.; McGovern, Jacqui A.; Broszczak, Daniel A.; Parker, Christina N.; Upton, Zee

    2015-01-01

    Significance: Chronic wounds represent a major burden on global healthcare systems and reduce the quality of life of those affected. Significant advances have been made in our understanding of the biochemistry of wound healing progression. However, knowledge regarding the specific molecular processes influencing chronic wound formation and persistence remains limited. Recent Advances: Generally, healing of acute wounds begins with hemostasis and the deposition of a plasma-derived provisional matrix into the wound. The deposition of plasma matrix proteins is known to occur around the microvasculature of the lower limb as a result of venous insufficiency. This appears to alter limb cutaneous tissue physiology and consequently drives the tissue into a ‘preconditioned’ state that negatively influences the response to wounding. Critical Issues: Processes, such as oxygen and nutrient suppression, edema, inflammatory cell trapping/extravasation, diffuse inflammation, and tissue necrosis are thought to contribute to the advent of a chronic wound. Healing of the wound then becomes difficult in the context of an internally injured limb. Thus, interventions and therapies for promoting healing of the limb is a growing area of interest. For venous ulcers, treatment using compression bandaging encourages venous return and improves healing processes within the limb, critically however, once treatment concludes ulcers often reoccur. Future Directions: Improved understanding of the composition and role of pericapillary matrix deposits in facilitating internal limb injury and subsequent development of chronic wounds will be critical for informing and enhancing current best practice therapies and preventative action in the wound care field. PMID:25785239

  15. Canadian Federalism in Design and Practice: The Mechanics of a Permanently Provisional Constitution

    Directory of Open Access Journals (Sweden)

    Gardner James A.

    2017-12-01

    Full Text Available This paper examines the interaction between constitutional design and practice through a case study of Canadian federalism. Focusing on the federal architecture of the Canadian Constitution, the paper examines how subnational units in Canada actually compete with the central government, emphasizing the concrete strategies and tactics they most commonly employ to get their way in confrontations with central authority. The evidence affirms that constitutional design and structure make an important difference in the tactics and tools available to subnational units in a federal system, but that design is not fully constraining: there is considerable evidence of extraconstitutional innovation and improvisation by governments. Furthermore, changes in practice initiated by Canadian subnational actors have produced changes in the allocation of national and subnational authority that are plausibly characterized as constitutional in magnitude. The paper concludes that the design of the Canadian federal system may inadvertently undermine its capacity to stabilize itself at any particular point of constitutional evolution, making it ‘permanently provisional.’

  16. Soft Tissue Augmentation Techniques in Implants Placed and Provisionalized Immediately: A Systematic Review.

    Science.gov (United States)

    Rojo, Rosa; Prados-Frutos, Juan Carlos; Manchón, Ángel; Rodríguez-Molinero, Jesús; Sammartino, Gilberto; Calvo Guirado, José Luis; Gómez-de Diego, Rafael

    2016-01-01

    The aim of this study was to evaluate the effectiveness of techniques for soft tissue augmentation in the placement of immediate implants with and without provisionalization and to assess the quality of the reports in the literature. Randomized clinical trials, prospective clinical trials, and case series were included in this review. Clinical questions were formulated and organised according to the PICOS strategy. An electronic search was performed in PubMed, Cochrane Central Register of Controlled Trials, Scopus, and ISI Web up until June 2016. Interexaminer agreement on eligibility (k = 0.842; p = 0.103) and quality (k = 0.933; p < 0.001) was high. Methodological approaches were assessed using criteria based on design related forms designed by the Dutch Cochrane Collaboration. Finally, 14 papers were identified. In two studies, the implant survival was 90%; for the rest of the studies it was 100%. All studies reported favourable aesthetic, biological, and radiographic outcomes. Surgical and biomechanical complications of this technique were not relevant. This technique effectively compensates for the expected loss of volume of the oral soft tissues and maintains high success rates with good aesthetic results over time.

  17. ¿Cuánto cuesta el rescate bancario?: una estimación provisional

    Directory of Open Access Journals (Sweden)

    José Francisco Bellod Redondo

    2013-01-01

    Full Text Available en este trabajo presentamos una estimación provisional del importe de los recursos movilizados por las Administraciones Públicas en favor de los bancos españoles. Como el proceso de rescate bancario aún no ha finalizado y, como ciertos costes han de tener lugar en el futuro, la cuantificación es necesariamente incompleta. Según nuestras estimaciones los recursos inyectados ascienden a día de hoy a más de 126.000 millones de euros (11´9% del PIB, de los cuales más de 41.000 millones son irrecuperables. La venta de bancos a precios simbólicos ha sido una operación muy gravosa por la cual se han perdido 13.548 millones de euros. Aparte habría que computar los recursos procedentes del Banco Central Europeo (BCE, más de 340.000 millones de euros.

  18. Work and organisation in wood fuel systems. Provisional results from a pilot project

    Energy Technology Data Exchange (ETDEWEB)

    Ager, B. [Swedish Univ. of Agricultural Sciences, Dept. of Operational Efficiency, Garpenberg (Sweden); Soederqvist, A. [WE-Consulting AB, Tyresoe (Sweden)

    1996-12-31

    The use of wood fuels in Sweden has increased dramatically over the last few years. So far wood chips from tops and limbs and waste from the lumber/wood working industry have been the primary fuel sources. However, upgraded wood fuels, mainly in the shape of pellets, are rapidly gaining ground and used wood and short rotation forests are other sources under expansion. In the modern wood fuel sector new technology and production systems are being tested and introduced and new organisational structures and enterprises are developing. But rather few studies have been carried out concerning the conditions for the workers engaged in the production systems. An area which has attracted several studies is health hazards caused by various kinds of air pollutants, such as dust and moulds, but in most other areas knowledge is rather scarce. After a minor introductory study a comprehensive pilot project was formulated. The project is titled `Work and organisation in wood fuel systems` and will run from July 1996 to March 1998. The main objective of this project is to investigate working environment and work organisation in wood fuel systems in order to identify problems and ways of achieving improvement and development. This paper will discuss provisional results from studies of three selected production systems, which are especially common or expanding - harvest and transport of logging residues, production of wood pellets, and heating plants. (au)

  19. Redesign of a fixture mount to be used as an impression coping and a provisional abutment as well

    Directory of Open Access Journals (Sweden)

    Glenn Hsuan-Chen Chang

    2011-01-01

    Full Text Available Purpose: An integrated fixture mount/impression coping/ temporary abutment can provide many advantages for immediate loading of dental implants, such as simpler procedure, less chair time, cost reduction, and comfort for the patients. Materials and Methods: A newly designed dental implant fixture mount (DIFMA can be used as an impression coping for taking an immediate impression. An immediate load provisional prosthesis can then be fabricated shortly after implant placement to immediately load the implants. This fixture mount can also serve as a temporary abutment for immediate chair-side fabrication of provisional prosthesis. Two clinical cases are presented. Results: A clinical case utilizing the fixture mount abutment (DIFMA/implant assembly is presented. The precision of fitting between the impression copings and implants is secured with this system. The chair time for taking an immediate impression is greatly reduced. Less cost for the restoration is provided and patient comfort is delivered. Conclusions: More patient satisfaction can be conferred by employing the fixture mount in the process of immediate impression taking and as an immediate provisional abutment.

  20. Effect of dentin adhesives used as sealers and provisional cementation on bond strength of a resin cement to dentin.

    Science.gov (United States)

    Chieffi, Nicoletta; Sadek, Fernanda; Monticelli, Francesca; Goracci, Cecilia; Grandini, Simone; Davidson, Carel; Tay, Franklin R; Ferrari, Marco

    2006-04-01

    To evaluate the effects of dentin adhesives employed as resin sealers and provisional cementation on the bond strengths of a resin cement to dentin. A two-step etch-and-rinse adhesive (Excite DSC--Group 1) and two-step self-etch adhesive (AdheSE--Group 2) were applied to exposed dentin surfaces prepared from human molars (N=4). Water was used instead of a resin sealer in control Groups 3 and 4. A eugenol-free provisional cement (except for Group 4) was applied to the treated surfaces. After storing in distilled water for 1 week, the provisional cement was removed and cylindrical composite blocks were luted with a resin cement (Variolink II). 0.9 x 0.9 mm sticks were produced from these luted specimens for microtensile bond testing and SEM examination. One-way ANOVA revealed that neither the resin sealer nor the temporary eugenol-free cement had a negative effect on the final bond strength (P> 0.05). Mixed failures were predominantly identified from SEM.

  1. Immediate implant placement and provisionalization with and without a connective tissue graft: an analysis of facial gingival tissue thickness.

    Science.gov (United States)

    Rungcharassaeng, Kitichai; Kan, Joseph Y K; Yoshino, Shuji; Morimoto, Taichiro; Zimmerman, Grenith

    2012-12-01

    Facial gingival tissue thickness (FGTT) is important for an esthetically pleasing anterior restoration since it determines the soft tissue's ability to conceal the underlying restorative material. The purpose of this study was to investigate the change in FGTT after immediate implant placement and provisionalization with and without a connective tissue graft. Patients with a failing maxillary anterior tooth planned for immediate implant placement and provisionalization with (CT group) or without (NCT group) a subepithelial connective tissue graft were included in this study. After tooth extraction, direct measurement of the FGTT was performed; subsequent measurements were performed at the time of definitive prosthesis placement. Data were analyzed using independent and paired t tests at a significance level of α = .05. There was no statistically significant difference in the mean FGTT at tooth extraction between the CT and NCT groups. At prosthesis delivery, the mean FGTT for the CT group was significantly greater than that of the NCT group. The mean FGTT of both groups at prosthesis delivery was significantly higher than that at tooth extraction. The mean change in FGTT in the CT group was also significantly greater than that in the NCT group. Immediate implant placement and provisionalization in conjunction with a connective tissue graft is more likely to result in sufficient peri-implant tissue thickness to conceal underlying implant restorative materials than when performed without a connective tissue graft.

  2. Fixed solar array designs for GPS space vehicles

    Science.gov (United States)

    Malachesky, P. A.; Simburger, E. J.; Zwibel, H. S.

    A risk reduction approach for the Global Positioning Satellite (GPS) replenishment satellite block which uses fixed rather than tracking solar arrays is described. This design study was carried out as a result of reliability and electromagnetic interference (EMI) concerns with solar array drive power and transfer systems (SADPT). Fixed solar array designs eliminate the need for a SADPT, but result in larger arrays than tracking arrays in order to maintain acceptable end-of-life (EOL) performance. The weight increase due to the larger array is partially compensated for by the elimination of the SADPT. If advanced solar arrays and/or lightweight array designs are used, fixed array designs can lead to weight savings over baseline silicon cell-based designs.

  3. Multidisciplinary approach of ectodermal dysplasia with implant retained fixed prosthesis

    Directory of Open Access Journals (Sweden)

    Vishnu Priya

    2013-01-01

    Full Text Available Ectodermal dysplasia represents a group of rare inherited conditions in which two or more ectodermally derived anatomical structures fail to develop. Early dental intervention can improve patient′s appearance, thereby minimizing associated emotional and psychological problems in these patients. Treatment requires a teamwork by medical personnel along with dental professionals of various specialties. Here, a rare case of a young female patient is presented with prosthetic management with implant supported fixed partial denture.

  4. -Functions on Quasimetric Spaces and Fixed Points for Multivalued Maps

    Directory of Open Access Journals (Sweden)

    Marín J

    2011-01-01

    Full Text Available We discuss several properties of -functions in the sense of Al-Homidan et al.. In particular, we prove that the partial metric induced by any weighted quasipseudometric space is a -function and show that both the Sorgenfrey line and the Kofner plane provide significant examples of quasimetric spaces for which the associated supremum metric is a -function. In this context we also obtain some fixed point results for multivalued maps by using Bianchini-Grandolfi gauge functions.

  5. Frontal fixed prosthetic restoration in edentulous space modification.

    Science.gov (United States)

    Picos, Andrei; Picos, Alina M; Stratica, Doriana M; Barbur, Adina; Dinu, Cristian

    2013-01-01

    This study case presents a 53 years old patient with severe aesthetic dysfunctions due to an ectopic maxillary canine associated with a frontal edentulous space. Orthodontic treatment proposition was refused by the patient. After canine extraction, metalo-ceramic fixed partial prosthesis successfully restored the aesthetic damage in the conditions of a non-gingival smile. Adapted abutment teeth preparations were made in order to provide necessary space for aesthetic alignment of artificial teeth in the pontic.

  6. Cystic partially differentiated nephroblastoma.

    Science.gov (United States)

    Puvaneswary, M; Macintosh, J; Cassey, J

    2006-06-01

    Cystic partially differentiated nephroblastoma is a relatively rare tumour of the kidney usually affecting infants. Cystic Wilms' tumour and multilocular cystic nephroma should be distinguished from cystic partially differentiated nephroblastoma. Multilocular cystic nephroma is a benign tumour whereas cystic Wilms' tumour is at the malignant end of the range of classification of such tumours. Cystic partially differentiated nephroblastoma may undergo local recurrence but there is no report of metastasis.

  7. Partial Rehabilitation with Distally Tilted and Straight Implants in the Posterior Maxilla with Immediate Loading Protocol: A Retrospective Cohort Study with 5-Year Follow-up.

    Science.gov (United States)

    Queridinha, Bruno Mt; Almeida, Ricardo F; Felino, António; de Araújo Nobre, Miguel; Maló, Paulo

    2016-01-01

    The purpose of this study was to compare the outcome of fixed partial prostheses in the posterior maxilla with two axially placed implants or one implant placed distally tilted and one axially placed implant following an immediate loading protocol. A sample of 60 patients was divided into two groups-group 1: 30 patients rehabilitated with one axially placed implant and one implant placed distally tilted in the posterior maxilla; group 2: 30 patients rehabilitated with two axially placed implants in the posterior maxilla. Outcome measures were implant survival based on function, marginal bone resorption, and the incidence of mechanical and biologic complications at 5 years; inferential statistics were used to analyze the intergroup and intragroup differences. The level of significance was set at 5%. No significant differences were found between both groups in survival, complications, or marginal bone resorption. One axially placed implant was lost at 58 months in group 1, rendering a cumulative survival estimate at 5 years of 96.7% and 98.3% in group 1 and the total sample, respectively (P = .317). Mechanical complications occurred in 16 patients (26.7%; n = 8 patients in each group; [P > .999]), consisting of fractures in the provisional prosthesis (n = 8 patients), chipped ceramics of the definitive prosthesis (n = 2 patients), loosening of prosthetic components (n = 5 patients), and fracture of an attachment screw (n = 1 patient). Biologic complications occurred in 5 patients (8.3%; group 1 = 4 patients; group 2 = 1 patient; [P = .161]), consisting of peri-implant pathology. The mean ± SD marginal bone loss was 2.02 ± 0.36 mm and 1.90 ± 0.69 mm for groups 1 and 2, respectively (P = .235). In group 1, the mean ± SD marginal bone loss was 1.92 ± 0.48 mm and 2.11 ± 0.44 mm for the implant placed distally tilted and axially placed implant, respectively; the difference was significant (P implants placed distally tilted together with axially placed implants or

  8. Deriving a provisional tolerable intake for intravenous exposure to silver nanoparticles released from medical devices.

    Science.gov (United States)

    Savery, Laura C; Viñas, René; Nagy, Amber M; Pradeep, Prachi; Merrill, Stephen J; Hood, Alan M; Malghan, Subhas G; Goering, Peter L; Brown, Ronald P

    2017-04-01

    Silver nanoparticles (AgNP) are incorporated into medical devices for their anti-microbial characteristics. The potential exposure and toxicity of AgNPs is unknown due to varying physicochemical particle properties and lack of toxicological data. The aim of this safety assessment is to derive a provisional tolerable intake (pTI) value for AgNPs released from blood-contacting medical devices. A literature review of in vivo studies investigating critical health effects induced from intravenous (i. v.) exposure to AgNPs was evaluated by the Annapolis Accords principles and Toxicological Data Reliability Assessment Tool (ToxRTool). The point of departure (POD) was based on an i. v. 28-day repeated AgNP (20 nm) dose toxicity study reporting an increase in relative spleen weight in rats with a 5% lower confidence bound of the benchmark dose (BMDL05) of 0.14 mg/kg bw/day. The POD was extrapolated to humans by a modifying factor of 1,000 to account for intraspecies variability, interspecies differences and lack of long-term toxicity data. The pTI for long-term i. v. exposure to 20 nm AgNPs released from blood-contacting medical devices was 0.14 μg/kg bw/day. This pTI may not be appropriate for nanoparticles of other physicochemical properties or routes of administration. The methodology is appropriate for deriving pTIs for nanoparticles in general. Published by Elsevier Inc.

  9. Provisional in-silico biopharmaceutics classification (BCS) to guide oral drug product development

    Science.gov (United States)

    Wolk, Omri; Agbaria, Riad; Dahan, Arik

    2014-01-01

    The main objective of this work was to investigate in-silico predictions of physicochemical properties, in order to guide oral drug development by provisional biopharmaceutics classification system (BCS). Four in-silico methods were used to estimate LogP: group contribution (CLogP) using two different software programs, atom contribution (ALogP), and element contribution (KLogP). The correlations (r2) of CLogP, ALogP and KLogP versus measured LogP data were 0.97, 0.82, and 0.71, respectively. The classification of drugs with reported intestinal permeability in humans was correct for 64.3%–72.4% of the 29 drugs on the dataset, and for 81.82%–90.91% of the 22 drugs that are passively absorbed using the different in-silico algorithms. Similar permeability classification was obtained with the various in-silico methods. The in-silico calculations, along with experimental melting points, were then incorporated into a thermodynamic equation for solubility estimations that largely matched the reference solubility values. It was revealed that the effect of melting point on the solubility is minor compared to the partition coefficient, and an average melting point (162.7°C) could replace the experimental values, with similar results. The in-silico methods classified 20.76% (±3.07%) as Class 1, 41.51% (±3.32%) as Class 2, 30.49% (±4.47%) as Class 3, and 6.27% (±4.39%) as Class 4. In conclusion, in-silico methods can be used for BCS classification of drugs in early development, from merely their molecular formula and without foreknowledge of their chemical structure, which will allow for the improved selection, engineering, and developability of candidates. These in-silico methods could enhance success rates, reduce costs, and accelerate oral drug products development. PMID:25284986

  10. Fixed effects analysis of variance

    CERN Document Server

    Fisher, Lloyd; Birnbaum, Z W; Lukacs, E

    1978-01-01

    Fixed Effects Analysis of Variance covers the mathematical theory of the fixed effects analysis of variance. The book discusses the theoretical ideas and some applications of the analysis of variance. The text then describes topics such as the t-test; two-sample t-test; the k-sample comparison of means (one-way analysis of variance); the balanced two-way factorial design without interaction; estimation and factorial designs; and the Latin square. Confidence sets, simultaneous confidence intervals, and multiple comparisons; orthogonal and nonorthologonal designs; and multiple regression analysi

  11. Fixed-point signal processing

    CERN Document Server

    Padgett, Wayne T

    2009-01-01

    This book is intended to fill the gap between the ""ideal precision"" digital signal processing (DSP) that is widely taught, and the limited precision implementation skills that are commonly required in fixed-point processors and field programmable gate arrays (FPGAs). These skills are often neglected at the university level, particularly for undergraduates. We have attempted to create a resource both for a DSP elective course and for the practicing engineer with a need to understand fixed-point implementation. Although we assume a background in DSP, Chapter 2 contains a review of basic theory

  12. Treatment of a severely atrophic maxilla using an immediately loaded, implant-supported fixed prosthesis without the use of bone grafts: a clinical report.

    Science.gov (United States)

    Sherry, Jeffrey S; Balshi, Thomas J; Sims, Lawrence O; Balshi, Stephen F

    2010-03-01

    This report describes a clinical approach to using the zygomatic and pterygomaxillary bones to provide additional anchorage for longer implants to support an immediately functional maxillary screw-retained provisional fixed prosthesis. The purpose is to report the problems of patients who have experienced the most severe form of maxillary alveolar resorption and to demonstrate a specific protocol which provides immediately loaded implants without bone grafting. (c) 2010 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  13. Treatment Using Functionally Fixed Prosthesis: A Case Report.

    Science.gov (United States)

    Chandra, Sumi; Singh, Ajay; Gupta, Himanshu; Chandra, Chetan

    2014-12-01

    Most dental practitioners as well as their patients prefer to have fixed rather than removable prosthesis. However, there are many clinical situations that prohibit the use of the fixed treatment modality. These clinical cases can vary from, simply not having the proper number of healthy teeth and/or implants to, the esthetically challenging cases of high smile lines and severe loss of alveolar support. The approach of using a traditional removable prosthesis in these situations has always been met with severe compromises. The functionally fixed restoration is a third modality of treatment that can solve many of the problems of the removable restoration and at the same time provide the same comfort and success of the fixed prosthesis. This restoration has a pontic assembly that is removed by the patient for periodontal maintenance. This article presents a case report which describes a technique for treatment of partially edentulous maxilla with severe loss of alveolar support using a fixed removable prosthesis/Andrew's bridge.

  14. The EBC TWO Study (European Bifurcation Coronary TWO): A Randomized Comparison of Provisional T-Stenting Versus a Systematic 2 Stent Culotte Strategy in Large Caliber True Bifurcations.

    Science.gov (United States)

    Hildick-Smith, David; Behan, Miles W; Lassen, Jens F; Chieffo, Alaide; Lefèvre, Thierry; Stankovic, Goran; Burzotta, Francesco; Pan, Manuel; Ferenc, Miroslaw; Bennett, Lorraine; Hovasse, Thomas; Spence, Mark J; Oldroyd, Keith; Brunel, Philippe; Carrie, Didier; Baumbach, Andreas; Maeng, Michael; Skipper, Nicola; Louvard, Yves

    2016-09-01

    For the treatment of coronary bifurcation lesions, a provisional strategy is superior to systematic 2-stent techniques for the most bifurcation lesions. However, complex anatomies with large side branches (SBs) with significant ostial disease length are considered by expert consensus to warrant a 2-stent technique upfront. This consensus view has not been scientifically assessed. Symptomatic patients with large caliber true bifurcation lesions (SB diameter ≥2.5 mm) and significant ostial disease length (≥5 mm) were randomized to either a provisional T-stent strategy or a dual stent culotte technique. Two hundred patients aged 64±10 years, 82% male, were randomized in 20 European centers. The clinical presentations were stable coronary disease (69%) and acute coronary syndromes (31%). SB stent diameter (2.67±0.27 mm) and length (20.30±5.89 mm) confirmed the extent of SB disease. Procedural success (provisional 97%, culotte 94%) and kissing balloon inflation (provisional 95%, culotte 98%) were high. Sixteen percent of patients in the provisional group underwent T-stenting. The primary end point (a composite of death, myocardial infarction, and target vessel revascularization at 12 months) occurred in 7.7% of the provisional T-stent group versus 10.3% of the culotte group (hazard ratio, 1.02; 95% confidence interval, 0.78-1.34; P=0.53). Procedure time, x-ray dose, and cost all favored the simpler procedure. When treating complex coronary bifurcation lesions with large stenosed SBs, there is no difference between a provisional T-stent strategy and a systematic 2-stent culotte strategy in a composite end point of death, myocardial infarction, and target vessel revascularization at 12 months. URL: http://www.clinicaltrials.gov. Unique identifier: NCT 01560455. © 2016 American Heart Association, Inc.

  15. Fixed Costs and Hours Constraints

    Science.gov (United States)

    Johnson, William R.

    2011-01-01

    Hours constraints are typically identified by worker responses to questions asking whether they would prefer a job with more hours and more pay or fewer hours and less pay. Because jobs with different hours but the same rate of pay may be infeasible when there are fixed costs of employment or mandatory overtime premia, the constraint in those…

  16. More on PT-Symmetry in (Generalized Effect Algebras and Partial Groups

    Directory of Open Access Journals (Sweden)

    J. Paseka

    2011-01-01

    Full Text Available We continue in the direction of our paper on PT-Symmetry in (Generalized Effect Algebras and Partial Groups. Namely we extend our considerations to the setting of weakly ordered partial groups. In this setting, any operator weakly ordered partial group is a pasting of its partially ordered commutative subgroups of linear operators with a fixed dense domain over bounded operators. Moreover, applications of our approach for generalized effect algebras are mentioned.

  17. Adhesives for fixed orthodontic bands.

    Science.gov (United States)

    Millett, Declan T; Glenny, Anne-Marie; Mattick, Rye Cr; Hickman, Joy; Mandall, Nicky A

    2016-10-25

    Orthodontic treatment involves using fixed or removable appliances (dental braces) to correct the positions of teeth. It has been shown that the quality of treatment result obtained with fixed appliances is much better than with removable appliances. Fixed appliances are, therefore, favoured by most orthodontists for treatment. The success of a fixed orthodontic appliance depends on the metal attachments (brackets and bands) being attached securely to the teeth so that they do not become loose during treatment. Brackets are usually attached to the front and side teeth, whereas bands (metal rings that go round the teeth) are more commonly used on the back teeth (molars). A number of adhesives are available to attach bands to teeth and it is important to understand which group of adhesives bond most reliably, as well as reducing or preventing dental decay during the treatment period. To evaluate the effectiveness of the adhesives used to attach bands to teeth during fixed appliance treatment, in terms of:(1) how often the bands come off during treatment; and(2) whether they protect the banded teeth against decay during fixed appliance treatment. The following electronic databases were searched: Cochrane Oral Health's Trials Register (searched 2 June 2016), Cochrane Central Register of Controlled Trials (CENTRAL; 2016, Issue 5) in the Cochrane Library (searched 2 June 2016), MEDLINE Ovid (1946 to 2 June 2016) and EMBASE Ovid (1980 to 2 June 2016). We searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform for ongoing trials. No restrictions were placed on the language or date of publication when searching the electronic databases. Randomised and controlled clinical trials (RCTs and CCTs) (including split-mouth studies) of adhesives used to attach orthodontic bands to molar teeth were selected. Patients with full arch fixed orthodontic appliance(s) who had bands attached to molars were included. All review authors

  18. Hyperbolic partial differential equations

    CERN Document Server

    Witten, Matthew

    1986-01-01

    Hyperbolic Partial Differential Equations III is a refereed journal issue that explores the applications, theory, and/or applied methods related to hyperbolic partial differential equations, or problems arising out of hyperbolic partial differential equations, in any area of research. This journal issue is interested in all types of articles in terms of review, mini-monograph, standard study, or short communication. Some studies presented in this journal include discretization of ideal fluid dynamics in the Eulerian representation; a Riemann problem in gas dynamics with bifurcation; periodic M

  19. Beginning partial differential equations

    CERN Document Server

    O'Neil, Peter V

    2011-01-01

    A rigorous, yet accessible, introduction to partial differential equations-updated in a valuable new edition Beginning Partial Differential Equations, Second Edition provides a comprehensive introduction to partial differential equations (PDEs) with a special focus on the significance of characteristics, solutions by Fourier series, integrals and transforms, properties and physical interpretations of solutions, and a transition to the modern function space approach to PDEs. With its breadth of coverage, this new edition continues to present a broad introduction to the field, while also addres

  20. Developing a provisional, international minimal dataset for Juvenile Dermatomyositis: for use in clinical practice to inform research.

    Science.gov (United States)

    McCann, Liza J; Arnold, Katie; Pilkington, Clarissa A; Huber, Adam M; Ravelli, Angelo; Beard, Laura; Beresford, Michael W; Wedderburn, Lucy R

    2014-01-01

    Juvenile dermatomyositis (JDM) is a rare but severe autoimmune inflammatory myositis of childhood. International collaboration is essential in order to undertake clinical trials, understand the disease and improve long-term outcome. The aim of this study was to propose from existing collaborative initiatives a preliminary minimal dataset for JDM. This will form the basis of the future development of an international consensus-approved minimum core dataset to be used both in clinical care and inform research, allowing integration of data between centres. A working group of internationally-representative JDM experts was formed to develop a provisional minimal dataset. Clinical and laboratory variables contained within current national and international collaborative databases of patients with idiopathic inflammatory myopathies were scrutinised. Judgements were informed by published literature and a more detailed analysis of the Juvenile Dermatomyositis Cohort Biomarker Study and Repository, UK and Ireland. A provisional minimal JDM dataset has been produced, with an associated glossary of definitions. The provisional minimal dataset will request information at time of patient diagnosis and during on-going prospective follow up. At time of patient diagnosis, information will be requested on patient demographics, diagnostic criteria and treatments given prior to diagnosis. During on-going prospective follow-up, variables will include the presence of active muscle or skin disease, major organ involvement or constitutional symptoms, investigations, treatment, physician global assessments and patient reported outcome measures. An internationally agreed minimal dataset has the potential to significantly enhance collaboration, allow effective communication between groups, provide a minimal standard of care and enable analysis of the largest possible number of JDM patients to provide a greater understanding of this disease. This preliminary dataset can now be developed into

  1. A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: An in vitrostudy

    Directory of Open Access Journals (Sweden)

    Bhavya Mohandas Amin

    2015-01-01

    Full Text Available Purpose: The purpose of this in vitro study was to evaluate and compare the primary marginal accuracy of four commercially available provisional materials (Protemp 4, Luxatemp Star, Visalys Temp and DPI tooth moulding powder and liquid at 2 time intervals (10 and 30 min. Materials and Methods: A customized stainless steel master model containing two interchangeable dies was used for fabrication of provisional crowns. Forty crowns (n = 10 were fabricated, and each crown was evaluated under a stereomicroscope. Vertical marginal discrepancies were noted and compared at 10 min since the start of mixing and then at 30 min. Observations and Results: Protemp 4 showed the least vertical marginal discrepancy (71.59 μ, followed by Luxatemp Star (91.93 μ at 10 min. DPI showed a marginal discrepancy of 95.94 μ while Visalys Temp crowns had vertical marginal discrepancy of 106.81 μ. There was a significant difference in the marginal discrepancy values of Protemp 4 and Visalys Temp. At 30 min, there was a significant difference between the marginal discrepancy of Protemp 4 crowns (83.11 μ and Visalys Temp crowns (128.97 μ and between Protemp 4 and DPI (118.88 μ. No significant differences were observed between Protemp 4 and Luxatemp Star. Conclusion: The vertical marginal discrepancy of temporary crowns fabricated from the four commercially available provisional materials ranged from 71 to 106 μ immediately after fabrication (at 10 min from the start of mix to 83-128 μ (30 min from the start of mix. The time elapsed after mixing had a significant influence on the marginal accuracy of the crowns.

  2. A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: An in vitro study

    Science.gov (United States)

    Amin, Bhavya Mohandas; Aras, Meena Ajay; Chitre, Vidya

    2015-01-01

    Purpose: The purpose of this in vitro study was to evaluate and compare the primary marginal accuracy of four commercially available provisional materials (Protemp 4, Luxatemp Star, Visalys Temp and DPI tooth moulding powder and liquid) at 2 time intervals (10 and 30 min). Materials and Methods: A customized stainless steel master model containing two interchangeable dies was used for fabrication of provisional crowns. Forty crowns (n = 10) were fabricated, and each crown was evaluated under a stereomicroscope. Vertical marginal discrepancies were noted and compared at 10 min since the start of mixing and then at 30 min. Observations and Results: Protemp 4 showed the least vertical marginal discrepancy (71.59 μ), followed by Luxatemp Star (91.93 μ) at 10 min. DPI showed a marginal discrepancy of 95.94 μ while Visalys Temp crowns had vertical marginal discrepancy of 106.81 μ. There was a significant difference in the marginal discrepancy values of Protemp 4 and Visalys Temp. At 30 min, there was a significant difference between the marginal discrepancy of Protemp 4 crowns (83.11 μ) and Visalys Temp crowns (128.97 μ) and between Protemp 4 and DPI (118.88 μ). No significant differences were observed between Protemp 4 and Luxatemp Star. Conclusion: The vertical marginal discrepancy of temporary crowns fabricated from the four commercially available provisional materials ranged from 71 to 106 μ immediately after fabrication (at 10 min from the start of mix) to 83–128 μ (30 min from the start of mix). The time elapsed after mixing had a significant influence on the marginal accuracy of the crowns. PMID:26097348

  3. The dual-zone therapeutic concept of managing immediate implant placement and provisional restoration in anterior extraction sockets.

    Science.gov (United States)

    Chu, Stephen J; Salama, Maurice A; Salama, Henry; Garber, David A; Saito, Hanae; Sarnachiaro, Guido O; Tarnow, Dennis P

    2012-01-01

    Improvements in implant designs have helped advance successful immediate anterior implant placement into fresh extraction sockets. Clinical techniques described in this case enable practitioners to achieve predictable esthetic success using a method that limits the amount of buccal contour change of the extraction site ridge and potentially enhances the thickness of the peri-implant soft tissues coronal to the implant-abutment interface. This approach involves atraumatic tooth removal without flap elevation, and placing a bone graft into the residual gap around an immediate fresh-socket anterior implant with a screw-retained provisional restoration acting as a prosthetic socket seal device.

  4. A provisional regulatory gene network for specification of endomesoderm in the sea urchin embryo

    Science.gov (United States)

    Davidson, Eric H.; Rast, Jonathan P.; Oliveri, Paola; Ransick, Andrew; Calestani, Cristina; Yuh, Chiou-Hwa; Minokawa, Takuya; Amore, Gabriele; Hinman, Veronica; Arenas-Mena, Cesar; hide

    2002-01-01

    We present the current form of a provisional DNA sequence-based regulatory gene network that explains in outline how endomesodermal specification in the sea urchin embryo is controlled. The model of the network is in a continuous process of revision and growth as new genes are added and new experimental results become available; see http://www.its.caltech.edu/mirsky/endomeso.htm (End-mes Gene Network Update) for the latest version. The network contains over 40 genes at present, many newly uncovered in the course of this work, and most encoding DNA-binding transcriptional regulatory factors. The architecture of the network was approached initially by construction of a logic model that integrated the extensive experimental evidence now available on endomesoderm specification. The internal linkages between genes in the network have been determined functionally, by measurement of the effects of regulatory perturbations on the expression of all relevant genes in the network. Five kinds of perturbation have been applied: (1) use of morpholino antisense oligonucleotides targeted to many of the key regulatory genes in the network; (2) transformation of other regulatory factors into dominant repressors by construction of Engrailed repressor domain fusions; (3) ectopic expression of given regulatory factors, from genetic expression constructs and from injected mRNAs; (4) blockade of the beta-catenin/Tcf pathway by introduction of mRNA encoding the intracellular domain of cadherin; and (5) blockade of the Notch signaling pathway by introduction of mRNA encoding the extracellular domain of the Notch receptor. The network model predicts the cis-regulatory inputs that link each gene into the network. Therefore, its architecture is testable by cis-regulatory analysis. Strongylocentrotus purpuratus and Lytechinus variegatus genomic BAC recombinants that include a large number of the genes in the network have been sequenced and annotated. Tests of the cis-regulatory predictions of

  5. Provisional in-silico biopharmaceutics classification (BCS to guide oral drug product development

    Directory of Open Access Journals (Sweden)

    Wolk O

    2014-09-01

    Full Text Available Omri Wolk, Riad Agbaria, Arik Dahan Department of Clinical Pharmacology, School of Pharmacy, Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva, Israel Abstract: The main objective of this work was to investigate in-silico predictions of physicochemical properties, in order to guide oral drug development by provisional biopharmaceutics classification system (BCS. Four in-silico methods were used to estimate LogP: group contribution (CLogP using two different software programs, atom contribution (ALogP, and element contribution (KLogP. The correlations (r2 of CLogP, ALogP and KLogP versus measured LogP data were 0.97, 0.82, and 0.71, respectively. The classification of drugs with reported intestinal permeability in humans was correct for 64.3%–72.4% of the 29 drugs on the dataset, and for 81.82%–90.91% of the 22 drugs that are passively absorbed using the different in-silico algorithms. Similar permeability classification was obtained with the various in-silico methods. The in-silico calculations, along with experimental melting points, were then incorporated into a thermodynamic equation for solubility estimations that largely matched the reference solubility values. It was revealed that the effect of melting point on the solubility is minor compared to the partition coefficient, and an average melting point (162.7°C could replace the experimental values, with similar results. The in-silico methods classified 20.76% (±3.07% as Class 1, 41.51% (±3.32% as Class 2, 30.49% (±4.47% as Class 3, and 6.27% (±4.39% as Class 4. In conclusion, in-silico methods can be used for BCS classification of drugs in early development, from merely their molecular formula and without foreknowledge of their chemical structure, which will allow for the improved selection, engineering, and developability of candidates. These in-silico methods could enhance success rates, reduce costs, and accelerate oral drug products development

  6. Provisional clinical chemistry parameters in the African Sharptooth catfish (Clarias gariepinus

    Directory of Open Access Journals (Sweden)

    J.G. Myburgh

    2008-05-01

    Full Text Available This is a reprint of Myburgh, J.G. Botha, C.J. Booyse, D.G. & Reyers, F., 2008, 'Provisional clinical chemistry parameters in the African Sharptooth catfish (Clarias gariepinus', Journal of the South African Veterinary Association 79(4, 156-160. http://dx.doi.org/10.4102/jsava.v79i4.265:Pollution affects aquatic systems worldwide and there is an urgent need for efficient monitoring. Fish are generally sensitive to their environment and are thus considered to be valuable bioindicator species. The African Sharptooth catfish (Clarias gariepinus is particularly important in this respect because of its very wide distribution. In order to use C. gariepinus as a bioindicator species its baseline clinical chemistry must be defined. Existing data are scarce, and the objective of this work was therefore to establish clinical chemistry parameters for C. gariepinus. Blood was collected from male and female catfish and a number of clinical chemistry parameters were determined. Plasma protein values, but particularly those of plasma albumin, were found to be very low, approximately half the value for dogs, but similar to the values in Channel catfish (Ictalurus punctatus. Plasma urea values in Sharptooth catfish were found to be much lower than in dogs, but only marginally lower than in Channel catfish. Plasma creatinine in Sharptooth catfish, however, was only a quarter of that of dogs and one third of that found in Channel catfish. These findings may have implications for using urea and / or creatinine as an index of renal glomerular filtration, as is done in mammals. Plasma enzyme activity ranges were much lower in Sharptooth catfish than in dogs, particularly for alkaline phosphatase (ALP and alanine aminotransferase (ALT. By comparison, Channel catfish have an even lower ALT activity range but an ALP range that is very similar to dogs. The implications for using these enzymes as markers for liver disease are not clear from these data, as factors such as

  7. Partial knee replacement - slideshow

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/presentations/100225.htm Partial knee replacement - series—Normal anatomy To use the sharing ... A.M. Editorial team. Related MedlinePlus Health Topics Knee Replacement A.D.A.M., Inc. is accredited ...

  8. Beginning partial differential equations

    CERN Document Server

    O'Neil, Peter V

    2014-01-01

    A broad introduction to PDEs with an emphasis on specialized topics and applications occurring in a variety of fields Featuring a thoroughly revised presentation of topics, Beginning Partial Differential Equations, Third Edition provides a challenging, yet accessible,combination of techniques, applications, and introductory theory on the subjectof partial differential equations. The new edition offers nonstandard coverageon material including Burger's equation, the telegraph equation, damped wavemotion, and the use of characteristics to solve nonhomogeneous problems. The Third Edition is or

  9. Formulaic language: fixed and varied

    OpenAIRE

    Schmitt, Norbert

    2006-01-01

    Formulaic language has been shown to be an important component of language usage. This paper summarizes evidence of this importance and then goes on to focus upon two key characteristics of formulaic language: fixedness and variability. Formulaic language is usually conceptualized as being basically fixed, but examples are given to illustrate that in many cases formulaic language contains a considerable amount of variation. The degree and type of variation depends on which kind of formulaic l...

  10. Factors influencing bonding fixed restorations

    OpenAIRE

    Medić Vesna; Obradović-Đuričić Kosovka

    2008-01-01

    INTRODUCTION Crown displacement often occurs because the features of tooth preparations do not counteract the forces directed against restorations. OBJECTIVE The purpose of this study was to evaluate the effect of preparation designs on retention and resistance of fixed restorations. METHOD The study was performed on 64 differently sized stainless steel dies. Also, caps which were used for evaluated retention were made of stainless steel for each die. After cementing the caps on experimental ...

  11. Oral rehabilitation with fixed prosthesis

    OpenAIRE

    Watanabe Velásquez, Romel; Dpto. Académico Estomatología Rehabilitadora. Facultad Odontología. UNMSM. Lima, Perú.; Salcedo Moncada, Doris; Dpto. Académico Estomatología Rehabilitadora. Facultad Odontología. UNMSM. Lima, Perú.; Ochoa Tataje, Julio; Dpto. Académico Estomatología Rehabilitadora. Facultad Odontología. UNMSM. Lima, Perú.; Horna Palomino, Hernán; Dpto. Académico Estomatología Rehabilitadora. Facultad Odontología. UNMSM. Lima, Perú.; Herrera Cisneros, Marco; Dpto. Académico Estomatología Rehabilitadora. Facultad Odontología. UNMSM. Lima, Perú.; Paz Fernández, Juan José; Dpto. Académico Estomatología Rehabilitadora. Facultad Odontología. UNMSM. Lima, Perú.

    2014-01-01

    This treatment was carried out in a 58 years old male patient, who has had the antecedent of a car crash accident two years before; he loosed several teeth and fractured others. Pulp necrosis and alteration of occlusal plane occurred. Because of the pathologies presented, it was installed a multidisciplinary treatment phase having periodontal, endodontic, surgical and orthodontic procedures, tehe installation of posts, crowns and fixed bridges. Treatment was carried out for five months. El...

  12. Nueva indicación de implantes cigomáticos para la rehabilitación fija de desdentados parciales: reporte de un caso A new indication for Zygomatic implants for the fixed rehabilitation of the partially edentulous patient: Case report

    Directory of Open Access Journals (Sweden)

    M.F. Pintor Willcock

    2007-08-01

    Full Text Available Los implantes cigomáticos están indicados en casos de reabsorciones maxilares severas. Esto permitiría eliminar la necesidad de injertos óseos o levantamientos de seno de manera de recuperar el volumen óseo necesario para rehabilitar en base a implantes convencionales, disminuyendo así la morbilidad y el tiempo de tratamiento. A continuación presentamos caso de paciente desdentado parcial superior, clase I de Kennedy, en el cual se utilizaron dos implantes cigomáticos a cada lado, emergiendo sobre el reborde, a través de una modificación de la técnica.Zygomatic Implants are used in the rehabilitation of severely resorbed maxillas. This eliminates the necessity of bone grafting or sinus augmentation to restore the osseous volume necessary for conventional implant rehabilitation. This also minimizes morbidity and treatment times. We present the case of a patient with a partially edentulous upper ridge, Kennedy class I, in whom two zygomatic implants were placed in each side, that emerged over the alveolar ridge crest as a result of a technique modification.

  13. A fixed-point farrago

    CERN Document Server

    Shapiro, Joel H

    2016-01-01

    This text provides an introduction to some of the best-known fixed-point theorems, with an emphasis on their interactions with topics in analysis. The level of exposition increases gradually throughout the book, building from a basic requirement of undergraduate proficiency to graduate-level sophistication. Appendices provide an introduction to (or refresher on) some of the prerequisite material and exercises are integrated into the text, contributing to the volume’s ability to be used as a self-contained text. Readers will find the presentation especially useful for independent study or as a supplement to a graduate course in fixed-point theory. The material is split into four parts: the first introduces the Banach Contraction-Mapping Principle and the Brouwer Fixed-Point Theorem, along with a selection of interesting applications; the second focuses on Brouwer’s theorem and its application to John Nash’s work; the third applies Brouwer’s theorem to spaces of infinite dimension; and the fourth rests ...

  14. Discoloration of gingiva in the presence of fixed dental restorations

    Directory of Open Access Journals (Sweden)

    Ristić Ljubiša

    2005-01-01

    Full Text Available Aim. To investigate the frequency of discoloration of gingiva in the presence of fixed dental restorations, regarding the type of alloy of which restorations were made, and to show histopathological changes of discolored gingiva. Methods. One hundred and eighty four patients of both sexes were examined. The average age of the examinees was 52. They were divided into four groups according to the alloys from which their restorations were made. Standardized history questionnaires and clinical examination procedures were developed for this study. In ten examinees, whose teeth were indicated for extraction and who had a discoloration of gingiva, the samples of tissue were taken from the discolored gingiva for histopathological examination. Results. Our results showed the presence of discolored gingiva in all four groups. It was most frequent in the examinees with fixed restorations made of Ni-Cr alloy (43,5% and less frequent in those with fixed dental restorations made of gold alloy (26,5%. Histopathological examination showed the presence of tissue foreign body granulomas with giant cells in which the metal particles were found, partially as small and partially as large particles. Conclusion. Results suggested that grayish discoloration of gingiva was present in all four groups of examinees. The highest number of examinees with discolored gingiva was in the group with restorations made of Ni-Cr alloy. Grayish discoloration of gingiva was a consequence of incorporation of metal particles into gingival tissue.

  15. Effect of Heat Treatment on the Physical Properties of Provisional Crowns during Polymerization: An in Vitro Study

    Directory of Open Access Journals (Sweden)

    May L. Mei

    2015-04-01

    Full Text Available This study concerned the effect of heat treatment during setting on the physical properties of four resin-based provisional restorative materials: Duralay (polymethyl methacrylate, Trim II (polyethyl methacrylate, Luxatemp (bis-acrylic composite, and Protemp 4 (bis-acrylic composite. Specimens were prepared at 23, 37, or 60 °C for evaluation of flexural strength, surface roughness, color change and marginal discrepancy. Flexural strength was determined by a three-point bending test. Surface profile was studied using atomic force microscopy. Color change was evaluated by comparing the color of the materials before and after placement in coffee. A travelling microscope helped prepare standardized crowns for assessment of marginal discrepancy. Flexural strength of all tested materials cured at 23 °C or 37 °C did not significantly change. The surface roughness and marginal discrepancy of the materials increased at 60 °C curing temperature. Marginal discrepancies, color stability, and other physical properties of materials cured at 23 °C or 37 °C did not significantly change. Flexural strength of certain provisional materials cured at 60 °C increased, but there was also an increase in surface roughness and marginal discrepancy.

  16. The effect of dentin desensitizers on thermal changes in the pulp chamber during fabrication of provisional restorations.

    Science.gov (United States)

    Usumez, A; Ozturk, A N; Aykent, F

    2004-06-01

    The purpose of this study was to evaluate the effect of two dentin desensitizers on the pulp chamber temperature increase during fabrication of provisional restorations by a direct method. Sixty intact extracted mandibular third molars were prepared for a metal-ceramic complete crown. Then the teeth were randomly divided into three groups of 20 each. Group 1, no dentin desensitizer was used as the control group; group 2, a resin-based dentin desensitizer was selected; and group 3, the prepared teeth surfaces were coated with polyurethane cyanoacrylate adhesive. Each of the three groups was further divided into two polymerizing systems (autopolymerizing and a photopolymerizing) of 10 each. After insertion of the resin-filled matrix, the temperature change in the pulpal chamber was recorded with thermocouple connected to a data logger. anova indicated no significant differences for all combinations of desensitizing agents and curing methods (P > 0.05). When light cured composite or chemical curing acrylics were used to make temporary crowns, the presence of desensitizing agent did not reduce the temperature transmitted from the provisional material; the residual temperature rise transmitted was of such a magnitude as to cause concern regarding possible thermal injury to pulp.

  17. A "Jail Escape Technique" (JET) for distal side branch wiring during provisional stenting: Feasibility and first-in-man study.

    Science.gov (United States)

    Xiao, Han; Chen, Shengda; Wang, Guixue; Du, Ruolin; Song, Yaoming; Jin, Jun; Huang, Lan; Jabbour, Richard; Azzalini, Lorenzo; Zhao, Xiaohui

    2017-12-01

    To evaluate the feasibility of a novel technique for achieving distal SB access and improve strut apposition during provisional stenting. While distal rewiring and stent expansion toward the side branch (SB) are associated with better results during provisional stenting of coronary artery bifurcation lesions, these techniques are technically challenging and often leave unopposed struts near the carina. The "Jail Escape Technique" (JET) is performed by passing the proximal tip of the SB wire between the main vessel (MV) stent struts and balloon before implantation, allowing the MV stent to push the SB wire against the distal part of the carina. The MV stent can then be deployed without jailing the SB wire. Distal SB access and strut distribution at the carina were tested in phantom and swine models. Stent distortion, dislodgement forces, and material damage were evaluated with tensile testing. Human feasibility was then tested on 32 patients. Preclinical testing demonstrated that the SB wire was located at the most distal part of the carina and no strut malapposition at the carina was present after balloon inflation. Stent distortion, dislodgement forces, or material damage were not affected. JET was successfully performed in 30 of 32 patients. No major adverse cardiovascular events occurred in any patient at 6-month follow-up. The "JET" enables distal SB access and eliminates strut malapposition at the carina. Further studies with larger numbers of patients are needed to further investigate this technique. © 2017, Wiley Periodicals, Inc.

  18. Young novice drivers and the risky behaviours of parents and friends during the provisional (intermediate) licence phase: a brief report.

    Science.gov (United States)

    Scott-Parker, Bridie; Watson, Barry; King, Mark J; Hyde, Melissa K

    2014-08-01

    While there is research indicating that many factors influence the young novice driver's increased risk of road crash injury during the earliest stages of their independent driving, there is a need to further understand the relationship between the perceived risky driving behaviour of parents and friends and the risky behaviour of drivers with a Provisional (intermediate) licence. As part of a larger research project, 378 drivers aged 17-25 years (M=18.22, SD=1.59, 113 males) with a Provisional licence completed an online survey exploring the perceived riskiness of their parents' and friends' driving, and the extent to which they pattern (i.e. base) their driving behaviour on the driving of their parents and friends. Young drivers who reported patterning their driving on their friends, and who reported they perceived their friends to be risky drivers, reported more risky driving. The risky driving behaviour of young male drivers was associated with the perceived riskiness of their fathers' driving, whilst for female drivers the perceived riskiness of their mothers' driving approached significance. The development and application of countermeasures targeting the risky behaviour of same-sex parents appears warranted by the robust research findings. In addition, countermeasures need to encourage young people in general to be non-risky drivers; targeting the negative influence of risky peer groups specifically. Social norms interventions may minimise the influence of potentially-overestimated riskiness. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Algebraic partial Boolean algebras

    CERN Document Server

    Smith, D

    2003-01-01

    Partial Boolean algebras, first studied by Kochen and Specker in the 1960s, provide the structure for Bell-Kochen-Specker theorems which deny the existence of non-contextual hidden variable theories. In this paper, we study partial Boolean algebras which are 'algebraic' in the sense that their elements have coordinates in an algebraic number field. Several of these algebras have been discussed recently in a debate on the validity of Bell-Kochen-Specker theorems in the context of finite precision measurements. The main result of this paper is that every algebraic finitely-generated partial Boolean algebra B(T) is finite when the underlying space H is three-dimensional, answering a question of Kochen and showing that Conway and Kochen's infinite algebraic partial Boolean algebra has minimum dimension. This result contrasts the existence of an infinite (non-algebraic) B(T) generated by eight elements in an abstract orthomodular lattice of height 3. We then initiate a study of higher-dimensional algebraic partial...

  20. DK mini-culotte stenting in the treatment of true coronary bifurcation lesions: a propensity score matching comparison with T-provisional stenting.

    Science.gov (United States)

    Fan, Lin; Chen, Lianglong; Luo, Yukun; Zhang, Linlin; Zhong, Wenliang; Lin, Chaogui; Chen, Zhaoyang; Peng, Yafei; Zhen, Xingchun; Dong, Xianfeng

    2016-03-01

    The conventional culotte technique remains not to be widely used for the treatment of coronary bifurcation lesions due to its inherent drawbacks. Here, we developed a double kissing mini-culotte stenting (DK mini-culotte) and assessed its efficacy and safety by a propensity score matching comparison (PSM) with T-provisional stenting. From June 2010 to June 2012, a total of 223 consecutive patients with true coronary bifurcation lesions (TCBLs) were treated with DK mini-culotte (91 patients with 92 lesions) or T-provisional stenting (132 patients with 135 lesions). We performed a PSM to correct the confounders from clinical and lesion's characteristics. The primary endpoint was cumulative major adverse cardiac event (MACE) at 1 year including cardiac death, myocardial infarction, and target vessel revascularization or target lesion revascularization (TVR/TLR). The secondary endpoint was the rate of side branch (SB) restenosis at 12 months. After a PSM, there were 66 patients in each group. Additional SB stenting in the T-provisional group was performed in 10 (15.2 %) lesions. The incidence of 1-year cumulative MACE was 4.55 % for the DK mini-culotte versus 13.6 % for T-provisional stenting (P = 0.127), the rate of TVR/TLR was 1.52 % for DK mini-culotte versus 12.12 % for T-provisional stenting (P = 0.033). The SB binary restenosis rate was 5.6 % in the DK mini-culotte group and 22.4 % in the T-provisional group (P = 0.014). In summary, despite that there is no difference in MACE between groups, DK mini-culotte significantly reduce TVR/TLR and SB restenosis in the treatment of true coronary bifurcation lesions.

  1. Immediately loaded implants supporting fixed prostheses in the edentulous maxilla: a preliminary clinical and radiologic report.

    Science.gov (United States)

    Bergkvist, Göran; Sahlholm, Sten; Karlsson, Ulf; Nilner, Krister; Lindh, Christina

    2005-01-01

    To evaluate the survival rate of immediately loaded ITI sand-blasted, large-grit, acid-etched (SLA) solid-screw dental implants in the edentulous maxilla after 8 months of loading. Twenty-eight patients (mean age 63 years) with edentulous maxillae each received 6 implants and 1 implant-supported fixed provisional prosthesis within 24 hours after surgery. After a mean healing time of 15 weeks, the patient received a definitive, screw-retained, implant-supported fixed prosthesis. A total of 168 implants were placed. Clinical parameters were registered after 1 month of loading with the implant-supported fixed prostheses as well as 8 months after implant placement. Radiologic examinations and assessments were made at implant placement and after 8 months. The mean marginal bone level at implant placement was 1.6 mm (range 0 to 5.1; SD 1.1) apical of the reference point (the implant shoulder). The mean marginal bone level at the 8-month follow-up was 3.2 mm (range 0.4 to 5.9; SD 1.1) apical of the reference point. Three implants failed during the healing period. The improved results in the present study might be a result of the positive effect of splinting the implants immediately after placement. ITI SLA solid-screw implants immediately loaded (ie, loaded within 24 hours of placement) and supporting fixed prostheses had successful survival rates after 8 months. The present results constitute a solid baseline for future follow-up studies.

  2. Methanol partial oxidation reformer

    Science.gov (United States)

    Ahmed, Shabbir; Kumar, Romesh; Krumpelt, Michael

    1999-01-01

    A partial oxidation reformer comprising a longitudinally extending chamber having a methanol, water and an air inlet and an outlet. An igniter mechanism is near the inlets for igniting a mixture of methanol and air, while a partial oxidation catalyst in the chamber is spaced from the inlets and converts methanol and oxygen to carbon dioxide and hydrogen. Controlling the oxygen to methanol mole ratio provides continuous slightly exothermic partial oxidation reactions of methanol and air producing hydrogen gas. The liquid is preferably injected in droplets having diameters less than 100 micrometers. The reformer is useful in a propulsion system for a vehicle which supplies a hydrogen-containing gas to the negative electrode of a fuel cell.

  3. Partial differential equations

    CERN Document Server

    Evans, Lawrence C

    2010-01-01

    This text gives a comprehensive survey of modern techniques in the theoretical study of partial differential equations (PDEs) with particular emphasis on nonlinear equations. The exposition is divided into three parts: representation formulas for solutions; theory for linear partial differential equations; and theory for nonlinear partial differential equations. Included are complete treatments of the method of characteristics; energy methods within Sobolev spaces; regularity for second-order elliptic, parabolic, and hyperbolic equations; maximum principles; the multidimensional calculus of variations; viscosity solutions of Hamilton-Jacobi equations; shock waves and entropy criteria for conservation laws; and, much more.The author summarizes the relevant mathematics required to understand current research in PDEs, especially nonlinear PDEs. While he has reworked and simplified much of the classical theory (particularly the method of characteristics), he primarily emphasizes the modern interplay between funct...

  4. Methanol partial oxidation reformer

    Science.gov (United States)

    Ahmed, S.; Kumar, R.; Krumpelt, M.

    1999-08-24

    A partial oxidation reformer is described comprising a longitudinally extending chamber having a methanol, water and an air inlet and an outlet. An igniter mechanism is near the inlets for igniting a mixture of methanol and air, while a partial oxidation catalyst in the chamber is spaced from the inlets and converts methanol and oxygen to carbon dioxide and hydrogen. Controlling the oxygen to methanol mole ratio provides continuous slightly exothermic partial oxidation reactions of methanol and air producing hydrogen gas. The liquid is preferably injected in droplets having diameters less than 100 micrometers. The reformer is useful in a propulsion system for a vehicle which supplies a hydrogen-containing gas to the negative electrode of a fuel cell. 7 figs.

  5. Fixed time versus fixed range reverberation calculation: analytical solution.

    Science.gov (United States)

    Harrison, Chris H; Ainslie, Michael A

    2010-07-01

    Reverberation is commonly calculated by estimating the propagation loss to and from an elementary area, defined by transmitted pulse length and beam width, and treating the resulting backscatter from the area as a function of its range. In reality reverberation is strictly a function of time and contributions for a given time come from many ranges. Closed-form solutions are given for reverberation calculated both at fixed range and at fixed time isovelocity water and some variants of Lambert's law and linear reflection loss with an abrupt critical angle. These are derived by considering the shape of the two-way scattered multipath pulse envelope from a point scatterer. The ratio of these two solutions is shown to depend on the dominant propagation angle spread for the particular range or time. The ratio is largest at intermediate ranges (though typically less than 1 dB) and depends explicitly on the critical angle. At longer ranges mode-stripping reduces the propagation angle spread and the ratio reduces ultimately to unity. At short range the ratio is also close to unity although interpreting it requires care.

  6. Results on n-tupled fixed points in complete asymptotically regular metric spaces

    Directory of Open Access Journals (Sweden)

    Anupam Sharma

    2014-10-01

    Full Text Available The notion of n-tupled fixed point is introduced by Imdad, Soliman, Choudhury and Das, Jour. of Operators, Vol. 2013, Article ID 532867. In this manuscript, we prove some n-tupled fixed point theorems (for even n for mappings having mixed monotone property in partially ordered complete asymptotically regular metric spaces. Our main theorem improves the corresponding results of Imdad, Sharma and Rao (M. Imdad, A. Sharma, K.P.R. Rao, Generalized n-tupled fixed point theorems for nonlinear contractions, preprint.

  7. Dynamics of partial control.

    Science.gov (United States)

    Sabuco, Juan; Sanjuán, Miguel A F; Yorke, James A

    2012-12-01

    Safe sets are a basic ingredient in the strategy of partial control of chaotic systems. Recently we have found an algorithm, the sculpting algorithm, which allows us to construct them, when they exist. Here we define another type of set, an asymptotic safe set, to which trajectories are attracted asymptotically when the partial control strategy is applied. We apply all these ideas to a specific example of a Duffing oscillator showing the geometry of these sets in phase space. The software for creating all the figures appearing in this paper is available as supplementary material.

  8. GOLD and the fixed ratio

    Directory of Open Access Journals (Sweden)

    Vestbo J

    2012-09-01

    Full Text Available Jørgen VestboUniversity of Manchester, Manchester, UKI read with interest the paper entitled "Diagnosis of airway obstruction in the elderly: contribution of the SARA study" by Sorino et al in a recent issue of this journal.1 Being involved in the Global Initiative for Obstructive Lung Diseases (GOLD, it is nice to see the interest sparked by the GOLD strategy document. However, in the paper by Sorino et al, there are a few misunderstandings around GOLD and the fixed ratio (forced expiratory volume in 1 second/forced volume vital capacity < 0.70 that need clarification.View original paper by Sorino and colleagues.

  9. Widespread bullous fixed drug eruption.

    Science.gov (United States)

    Patell, Rushad D; Dosi, Rupal V; Shah, Purav C; Joshi, Harshal S

    2014-02-07

    A 53-year-old man developed a widespread erythematous eruption which rapidly evolved into fluid-filled bulla mostly involving the distal areas of all four limbs and erosions on the oral as well as anogenital mucosa. Based on clinical presentation, chronology of drug exposure, past events and histopathology as diagnosis of widespread bullous fixed drug eruption was made over Steven Johnson-toxic epidermal necrolysis syndrome. Steroids were deferred and the lesions healed with minimal pigmentation within a week. Differentiating between the two entities has been historically difficult, and yet can have significant therapeutic and prognostic implications.

  10. A retrospective cohort study of 113 patients rehabilitated with immediately loaded maxillary cross-arch fixed dental prostheses in combination with immediate implant placement.

    Science.gov (United States)

    Gillot, Luc; Cannas, Bernard; Buti, Jacopo; Noharet, Renaud

    2012-01-01

    To retrospectively evaluate the outcome of immediately loaded cross-arch fixed dental prostheses 6 months after loading. A second aim was to compare survival rates of implants placed in healed versus fresh extraction sites. In total, 113 consecutive patients about to have their maxillae rendered fully edentulous (mean extractions per patient: 6.7 teeth) received four to eight implants each (total number = 675) which were immediately placed in healed sites (323 implants, 47.9%) or fresh sockets (352 implants, 52.1%). Immediate loading of provisional prostheses was performed and all patients were followed up for 6 months. The success criteria included prosthesis success, assessment of individual implant stability and complications. No patients dropped out and all 113 patients received definitive fixed prostheses after 6 months of loading. The overall implant survival rate after 6 months was 99.1%. Six implants were lost in 6 patients (5.3%). Five of them were inserted in fresh extraction sockets (1.4%) and one in a healed site (0.3%). No significant difference (P = 0.1621) was found for implants placed in healed sites versus fresh extraction sites. Ten patients had fractures of the provisional prostheses as complications. Immediate implant placement and loading resulted in high implant as well as prosthetic survival rates. Placement in healed or fresh extraction bone sites may not influence implant survival.

  11. Fundamental partial compositeness

    DEFF Research Database (Denmark)

    Sannino, Francesco; Strumia, Alessandro; Tesi, Andrea

    2016-01-01

    We construct renormalizable Standard Model extensions, valid up to the Planck scale, that give a composite Higgs from a new fundamental strong force acting on fermions and scalars. Yukawa interactions of these particles with Standard Model fermions realize the partial compositeness scenario. Unde...

  12. Partially ordered models

    NARCIS (Netherlands)

    Fernandez, R.; Deveaux, V.

    2010-01-01

    We provide a formal definition and study the basic properties of partially ordered chains (POC). These systems were proposed to model textures in image processing and to represent independence relations between random variables in statistics (in the later case they are known as Bayesian networks).

  13. Partial Biotinidase Deficiency

    OpenAIRE

    J Gordon Millichap

    1990-01-01

    The symptoms, biochemical features and inheritance pattern of partial biotinidase deficiency have been studied at the Departments of Human Genetics and Pediatrics, Medical College of Virginia, Richmond, VA; the State Laboratory Institute, Massachusetts Department of Public Health; Massachusetts General Hospital, Boston; the Lincoln Clinic, NB; and the Division of Human Genetics, university of Maryland School of Medicine, Baltimore.

  14. Partial gravity habitat study

    Science.gov (United States)

    Capps, Stephen; Lorandos, Jason; Akhidime, Eval; Bunch, Michael; Lund, Denise; Moore, Nathan; Murakawa, Kiosuke

    1989-01-01

    The purpose of this study is to investigate comprehensive design requirements associated with designing habitats for humans in a partial gravity environment, then to apply them to a lunar base design. Other potential sites for application include planetary surfaces such as Mars, variable-gravity research facilities, and a rotating spacecraft. Design requirements for partial gravity environments include locomotion changes in less than normal earth gravity; facility design issues, such as interior configuration, module diameter, and geometry; and volumetric requirements based on the previous as well as psychological issues involved in prolonged isolation. For application to a lunar base, it is necessary to study the exterior architecture and configuration to insure optimum circulation patterns while providing dual egress; radiation protection issues are addressed to provide a safe and healthy environment for the crew; and finally, the overall site is studied to locate all associated facilities in context with the habitat. Mission planning is not the purpose of this study; therefore, a Lockheed scenario is used as an outline for the lunar base application, which is then modified to meet the project needs. The goal of this report is to formulate facts on human reactions to partial gravity environments, derive design requirements based on these facts, and apply the requirements to a partial gravity situation which, for this study, was a lunar base.

  15. Partially Hidden Markov Models

    DEFF Research Database (Denmark)

    Forchhammer, Søren Otto; Rissanen, Jorma

    1996-01-01

    Partially Hidden Markov Models (PHMM) are introduced. They differ from the ordinary HMM's in that both the transition probabilities of the hidden states and the output probabilities are conditioned on past observations. As an illustration they are applied to black and white image compression wher...

  16. Honesty in partial logic

    NARCIS (Netherlands)

    W. van der Hoek (Wiebe); J.O.M. Jaspars; E. Thijsse

    1995-01-01

    textabstractWe propose an epistemic logic in which knowledge is fully introspective and implies truth, although truth need not imply epistemic possibility. The logic is presented in sequential format and is interpreted in a natural class of partial models, called balloon models. We examine the

  17. Partial Remission Definition

    DEFF Research Database (Denmark)

    Andersen, Marie Louise Max; Hougaard, Philip; Pörksen, Sven

    2014-01-01

    OBJECTIVE: To validate the partial remission (PR) definition based on insulin dose-adjusted HbA1c (IDAA1c). SUBJECTS AND METHODS: The IDAA1c was developed using data in 251 children from the European Hvidoere cohort. For validation, 129 children from a Danish cohort were followed from the onset...

  18. Contractive definitions and discontinuity at fixed point

    Directory of Open Access Journals (Sweden)

    Ravindra K Bisht

    2017-04-01

    Full Text Available In this paper, we investigate some contractive definitions which are strong enough to generate a fixed point that do not force the mapping to be continuous at the fixed point. Finally, we obtain a fixed point theorem for generalized nonexpansive mappings in metric spaces by employing Meir-Keeler type conditions.

  19. Predicting the fix time of bugs

    NARCIS (Netherlands)

    Giger, E.; Pinzger, M.; Gall, H.C.

    2013-01-01

    Two important questions concerning the coordination of development effort are which bugs to fix first and how long it takes to fix them. In this paper we investigate empirically the relationships between bug report attributes and the time to fix. The objective is to compute prediction models that

  20. Utilization of nitrogen fixing trees

    Energy Technology Data Exchange (ETDEWEB)

    Brewbaker, J.L.; Beldt, R. van den; MacDicken, K.; Budowski, G.; Kass, D.C.L.; Russo, R.O.; Escalante, G.; Herrera, R.; Aranguren, J.; Arkcoll, D.B.; Doebereinger, J. (cord.)

    1983-01-01

    Six papers from the symposium are noted. Brewbaker, J.L., Beldt, R. van den, MacDicken, K. Fuelwood uses and properties of nitrogen-fixing trees, pp 193-204, (Refs. 15). Includes a list of 35 nitrogen-fixing trees of high fuelwood value. Budowski, G.; Kass, D.C.L.; Russo, R.O. Leguminous trees for shade, pp 205-222, (Refs. 68). Escalante, G., Herrera, R., Aranguren, J.; Nitrogen fixation in shade trees (Erythrina poeppigiana) in cocoa plantations in northern Venezuela, pp 223-230, (Refs. 13). Arkcoll, D.B.; Some leguminous trees providing useful fruits in the North of Brazil, pp 235-239, (Refs. 13). This paper deals with Parkia platycephala, Pentaclethra macroloba, Swartzia sp., Cassia leiandra, Hymenaea courbaril, dipteryz odorata, Inga edulis, I. macrophylla, and I. cinnamonea. Baggio, A.J.; Possibilities of the use of Gliricidia sepium in agroforestry systems in Brazil, pp 241-243; (Refs. 15). Seiffert, N.F.; Biological nitrogen and protein production of Leucaena cultivars grown to supplement the nutrition of ruminants, pp 245-249, (Refs. 14). Leucaena leucocephala cv. Peru, L. campina grande (L. leucocephala), and L. cunningham (L. leucocephalae) were promising for use as browse by beef cattle in central Brazil.

  1. A Unification of $G$ -Metric, Partial Metric, and $b$ -Metric Spaces

    OpenAIRE

    Hussain, Nawab; Rezaei Roshan, Jamal; Parvaneh, Vahid; Latif, Abdul

    2013-01-01

    Using the concepts of $G$ -metric, partial metric, and $b$ -metric spaces, we define a new concept of generalized partial $b$ -metric space. Topological and structural properties of the new space are investigated and certain fixed point theorems for contractive mappings in such spaces are obtained. Some examples are provided here to illustrate the usability of the obtained results.

  2. Prospective evaluation of a new protocol for the provisional use of perfusion imaging with exercise stress testing

    Energy Technology Data Exchange (ETDEWEB)

    Duvall, W.L. [Hartford Hospital, Division of Cardiology (Henry Low Heart Center), Hartford, CT (United States); Mount Sinai Medical Center, Division of Cardiology (Mount Sinai Heart), New York, NY (United States); Savino, John A.; Levine, Elliot J.; Croft, Lori B.; Henzlova, Milena J. [Mount Sinai Medical Center, Division of Cardiology (Mount Sinai Heart), New York, NY (United States); Hermann, Luke K. [Mount Sinai Medical Center, Department of Emergency Medicine, New York, NY (United States)

    2014-11-04

    Previous literature suggests that myocardial perfusion imaging (MPI) adds little to the prognosis of patients who exercise >10 metabolic equivalents (METs) during stress testing. With this in mind, we prospectively tested a provisional injection protocol in emergency department (ED) patients presenting for the evaluation of chest pain in which a patient would not receive an injection of radioisotope if adequate exercise was achieved without symptoms and a negative ECG response. All patients who presented to the ED over a 5-year period who were referred for stress testing as part of their ED evaluation were included. Patients considered for a provisional protocol were: exercise stress, age <65 years, no known coronary artery disease, and an interpretable rest ECG. Criteria for not injecting included a maximal predicted heart rate ≥85 %, ≥10 METs of exercise, no anginal symptoms during stress, and no ECG changes. Groups were compared based on stress test results, all-cause and cardiac mortality, follow-up cardiac testing, subsequent revascularization, and cost. A total of 965 patients were eligible with 192 undergoing exercise-only and 773 having perfusion imaging. After 41.6 ± 19.6 months of follow-up, all-cause mortality was similar in the exercise-only versus the exercise plus imaging group (2.6 % vs. 2.1 %, p = 0.59). There were no cardiac deaths in the exercise-only group. At 1 year there was no difference in the number of repeat functional stress tests (1.6 % vs. 2.1 %, p = 0.43), fewer angiograms (0 % vs. 4.0 %, p = 0.002), and a significantly lower cost (65 ± 332 vs 506 ± 1,991, p = 0.002; values are in US dollars) in the exercise-only group. The radiation exposure in the exercise plus imaging group was 8.4 ± 2.1 mSv. A provisional injection protocol has a very low mortality, few follow-up diagnostic tests, and lower cost compared to standard imaging protocols. If adopted it would decrease radiation exposure, save time and decrease health-care costs

  3. Immediate versus conventional loading for the maxilla with implants placed into fresh and healed extraction sites to support a full-arch fixed prosthesis: nonrandomized controlled clinical study.

    Science.gov (United States)

    Peñarrocha-Oltra, David; Covani, Ugo; Aparicio, Arnau; Ata-Ali, Javier; Peñarrocha-Diago, Miguel; Peñarrocha-Diago, Maria

    2013-01-01

    To compare immediate and conventional loading of fixed full-arch maxillary prostheses supported by implants placed in healed and fresh postextraction sites. This prospective, controlled, nonrandomized 12-month study included 30 consecutive patients requiring fixed full-arch maxillary prostheses supported by implants placed in healed and fresh extraction sites. Fifteen patients were treated with conventional loading (control group), and 15 were treated with immediate loading (test group). Each patient received six to eight implants; implants with insertion torque loaded and excluded from the analysis. Implant success, biologic and prosthetic complications, success of the immediately loaded provisional prostheses, and marginal bone loss were assessed and analyzed statistically. One test group patient failed to attend recall visits and was excluded from the study, and 16 implants did not achieve insertion torque of 35 Ncm and were excluded from analyses. The final sample included 29 patients and 193 implants (94 test implants, 99 control implants). Implant success rates were 96.8% (test) and 99.0% (control). In the test group, the most common complications were screw loosening and tooth fractures; in the control group, dentures caused discomfort and soft tissue irritation. The success rate of the immediately loaded prostheses was 100%. Average bone loss was 0.61 ± 0.21 mm for test implants and 0.53 ± 0.18 mm for control implants. Differences between loading protocols were not statistically significant. No significant differences in implant success and peri-implant marginal bone loss were seen in the current 12-month comparison of immediate and conventional loading of maxillary fixed full-arch prostheses. Biologic and prosthetic complications were rare with both loading protocols, and all immediately loaded provisional fixed prostheses performed successfully.

  4. Immediate placement and provisionalization of maxillary anterior single implant with guided bone regeneration, connective tissue graft, and coronally positioned flap procedures.

    Science.gov (United States)

    Waki, Tomonori; Kan, Joseph Y K

    2016-01-01

    Immediate implant placement and provisionalization in the esthetic zone have been documented with success. The benefit of immediate implant placement and provisionalization is the preservation of papillary mucosa. However, in cases with osseous defects presenting on the facial bony plate, immediate implant placement procedures have resulted in facial gingival recession. Subepithelial connective tissue grafts for immediate implant placement and provisionalization procedures have been reported with a good esthetic outcome. Biotype conversion around implants with subepithelial connective tissue grafts have been advocated, and the resulting tissues appear to be more resistant to recession. The dimensions of peri-implant mucosa in a thick biotype were significantly greater than in a thin biotype. Connective tissue graft with coronally positioned flap procedures on natural teeth has also been documented with success. This article describes a technique combining immediate implant placement, provisionalization, guided bone regeneration (GBR), connective tissue graft, and a coronally positioned flap in order to achieve more stable peri-implant tissue in facial osseous defect situations.

  5. Documentation to the NCES Common Core of Data Public Elementary/Secondary School Universe Survey: School Year 2011-12. Provisional Version 1a. NCES 2014-100

    Science.gov (United States)

    Keaton, Patrick

    2013-01-01

    The documentation for this provisional version 1a file of the National Center for Education Statistics' (NCES) Common Core of Data (CCD) Public Elementary/Secondary School Universe Survey for SY 2011-12, contains a brief description of the data collection, along with information required to understand and access the data file. The SY 2011-12…

  6. Documentation to the NCES Common Core of Data Local Education Agency Universe Survey: School Year 2011-12. Provisional Version 1a. NCES 2014-035

    Science.gov (United States)

    Keaton, Patrick

    2014-01-01

    This documentation is for the provisional version 1a file of the National Center for Education Statistics' (NCES) Common Core of Data (CCD) Local Education Agency (LEA) Universe Survey for SY 2011-12. It contains a brief description of the data collection, along with information required to understand and access the data file. The CCD is a…

  7. La protección cautelar en el contencioso administrativo colombiano: hacia un modelo de justicia provisional

    Directory of Open Access Journals (Sweden)

    Daniel Castaño Parra

    2010-12-01

    Full Text Available Siguiendo de cerca las elaboraciones teóricas que se han gestado en otras latitudes para justificar la tutela cautelar como una modalidad de justicia provisional en razón del estrecho vínculo que existe entre ésta y la tutela judicial efectiva, se intentará extrapolar dicho razonamiento al derecho positivo colombiano para caracterizar a la protección cautelar como una auténtica concreción del derecho a la justicia consagrado en los artículos 8.1 y 25 de la Convención Americana sobre Derechos Humanos, y en los artículos 29 y 229 de la Carta Política de 1991.

  8. The effect of placement of glass fibers and aramid fibers on the fracture resistance of provisional restorative materials.

    Science.gov (United States)

    Saygili, Gülbin; Sahmali, Sevil M; Demirel, Figen

    2003-01-01

    The fracture resistance of provisional restorations is an important concern for the restorative dentist. The fracture resistance of a material is directly related to its transverse strength. Six specimens of similar dimensions were prepared from three resins (PMMA, PEMA and BIS acryl-composite). The resins were reinforced with glass and aramid fibers. The samples were tested immediately after the material set, following seven days of wet storage using three-point compression loading. The results were analyzed with an analysis of variance (ANOVA). Fracture resistance of the specimens was statistically different (p fibers showed higher transverse strength (149.82 MPa). The fiber reinforcement of resin materials increased the strength values (20-50%). Within the limitations of this study, the transverse strengths of PMMA, PEMA and BIS acryl-resin composites were improved after reinforcement with glass and aramid fibers.

  9. Clinical outcomes following bioresorbable scaffold implantation for bifurcation lesions: Overall outcomes and comparison between provisional and planned double stenting strategy.

    Science.gov (United States)

    Kawamoto, Hiroyoshi; Latib, Azeem; Ruparelia, Neil; Miyazaki, Tadashi; Sticchi, Alessandro; Naganuma, Toru; Sato, Katsumasa; Figini, Filippo; Chieffo, Alaide; Carlino, Mauro; Montorfano, Matteo; Colombo, Antonio

    2015-10-01

    The aim of this study was to investigate clinical outcomes of patients treated with a provisional stenting (PS) versus a double stenting (DS) strategy for coronary bifurcation lesions with bioresorbable scaffolds (BRS). There are limited data available with regards to outcomes following BRS implantation for bifurcation lesions. A total of 132 bifurcation lesions treated with BRS between 2012 and 2014 were analyzed. Of the total of 132 bifurcation lesions, 10 lesions were treated without crossover stenting. 99 lesions (81%) were treated with a PS strategy and 23 lesions (19%) with a DS strategy. The DS group consisted of patients with a greater number of true bifurcation lesions (PS 52.0% vs. DS 91.3%: P strategy was employed. Larger studies are eagerly awaited to determine longer-term follow-up of this treatment strategy. © 2015 Wiley Periodicals, Inc.

  10. Partially composite Higgs models

    DEFF Research Database (Denmark)

    Alanne, Tommi; Buarque Franzosi, Diogo; Frandsen, Mads T.

    2018-01-01

    constraints. A small part of parameter space around the classically conformal limit is stable up to the Planck scale. This is however already strongly disfavored by LHC results. in different limits, the models realize both (partially) composite-Higgs and (bosonic) technicolor models and a dynamical extension......We study the phenomenology of partially composite-Higgs models where electroweak symmetry breaking is dynamically induced, and the Higgs is a mixture of a composite and an elementary state. The models considered have explicit realizations in terms of gauge-Yukawa theories with new strongly...... interacting fermions coupled to elementary scalars and allow for a very SM-like Higgs state. We study constraints on their parameter spaces from vacuum stability and perturbativity as well as from LHC results and find that requiring vacuum stability up to the compositeness scale already imposes relevant...

  11. The Paediatric Rheumatology International Trials Organisation provisional criteria for the evaluation of response to therapy in juvenile dermatomyositis.

    Science.gov (United States)

    Ruperto, Nicolino; Pistorio, Angela; Ravelli, Angelo; Rider, Lisa G; Pilkington, Clarissa; Oliveira, Sheila; Wulffraat, Nico; Espada, Graciela; Garay, Stella; Cuttica, Ruben; Hofer, Michael; Quartier, Pierre; Melo-Gomes, Jose; Reed, Ann M; Wierzbowska, Malgorzata; Feldman, Brian M; Harjacek, Miroslav; Huppertz, Hans-Iko; Nielsen, Susan; Flato, Berit; Lahdenne, Pekka; Michels, Harmut; Murray, Kevin J; Punaro, Lynn; Rennebohm, Robert; Russo, Ricardo; Balogh, Zsolt; Rooney, Madeleine; Pachman, Lauren M; Wallace, Carol; Hashkes, Philip; Lovell, Daniel J; Giannini, Edward H; Gare, Boel Andersson; Martini, Alberto

    2010-11-01

    To develop a provisional definition for the evaluation of response to therapy in juvenile dermatomyositis (DM) based on the Paediatric Rheumatology International Trials Organisation juvenile DM core set of variables. Thirty-seven experienced pediatric rheumatologists from 27 countries achieved consensus on 128 difficult patient profiles as clinically improved or not improved using a stepwise approach (patient's rating, statistical analysis, definition selection). Using the physicians' consensus ratings as the "gold standard measure," chi-square, sensitivity, specificity, false-positive and-negative rates, area under the receiver operating characteristic curve, and kappa agreement for candidate definitions of improvement were calculated. Definitions with kappa values >0.8 were multiplied by the face validity score to select the top definitions. The top definition of improvement was at least 20% improvement from baseline in 3 of 6 core set variables with no more than 1 of the remaining worsening by more than 30%, which cannot be muscle strength. The second-highest scoring definition was at least 20% improvement from baseline in 3 of 6 core set variables with no more than 2 of the remaining worsening by more than 25%, which cannot be muscle strength (definition P1 selected by the International Myositis Assessment and Clinical Studies group). The third is similar to the second with the maximum amount of worsening set to 30%. This indicates convergent validity of the process. We propose a provisional data-driven definition of improvement that reflects well the consensus rating of experienced clinicians, which incorporates clinically meaningful change in core set variables in a composite end point for the evaluation of global response to therapy in juvenile DM. Copyright © 2010 by the American College of Rheumatology.

  12. Arthroscopic partial medial meniscectomy

    Directory of Open Access Journals (Sweden)

    Dašić Žarko

    2011-01-01

    Full Text Available Background/Aim. Meniscal injuries are common in professional or recreational sports as well as in daily activities. If meniscal lesions lead to physical impairment they usually require surgical treatment. Arthroscopic treatment of meniscal injuries is one of the most often performed orthopedic operative procedures. Methods. The study analyzed the results of arthroscopic partial medial meniscectomy in 213 patients in a 24-month period, from 2006, to 2008. Results. In our series of arthroscopically treated medial meniscus tears we noted 78 (36.62% vertical complete bucket handle lesions, 19 (8.92% vertical incomplete lesions, 18 (8.45% longitudinal tears, 35 (16.43% oblique tears, 18 (8.45% complex degenerative lesions, 17 (7.98% radial lesions and 28 (13.14% horisontal lesions. Mean preoperative International Knee Documentation Committee (IKDC score was 49.81%, 1 month after the arthroscopic partial medial meniscectomy the mean IKDC score was 84.08%, and 6 months after mean IKDC score was 90.36%. Six months after the procedure 197 (92.49% of patients had good or excellent subjective postoperative clinical outcomes, while 14 (6.57% patients subjectively did not notice a significant improvement after the intervention, and 2 (0.93% patients had no subjective improvement after the partial medial meniscectomy at all. Conclusion. Arthroscopic partial medial meniscetomy is minimally invasive diagnostic and therapeutic procedure and in well selected cases is a method of choice for treatment of medial meniscus injuries when repair techniques are not a viable option. It has small rate of complications, low morbidity and fast rehabilitation.

  13. Mergers by Partial Acquisition

    OpenAIRE

    Lindqvist, Tobias

    2004-01-01

    This paper evaluates partial acquisition strategies. The model allows for buying a share of a firm before the actual acquisition takes place. Holding a share in a competing firm before the acquisition of another firm, outsider-toehold, eliminates the insiders' dilemma, i.e. profitable mergers do not occur. This strategy may thus be more profitable for a buyer than acquiring entire firms at once. Furthermore, the insiders' dilemma arises from the assumption of a positive externality on the out...

  14. Fracture strength and failure mode of maxillary implant-supported provisional single crowns: a comparison of composite resin crowns fabricated directly over PEEK abutments and solid titanium abutments.

    Science.gov (United States)

    Santing, Hendrik Jacob; Meijer, Henny J A; Raghoebar, Gerry M; Özcan, Mutlu

    2012-12-01

    Polyetheretherketone (PEEK) temporary abutments have been recently introduced for making implant-supported provisional single crowns. Little information is available in the dental literature on the durability of provisional implant-supported restorations. The objectives of this study were to evaluate the fracture strength of implant-supported composite resin crowns on PEEK and solid titanium temporary abutments, and to analyze the failure types. Three types of provisional abutments, RN synOcta Temporary Meso Abutment (PEEK; Straumann), RN synOcta Titanium Post for Temporary Restorations (Straumann), and Temporary Abutment Engaging NobRplRP (Nobel Biocare) were used, and provisional screw-retained crowns using composite resin (Solidex) were fabricated for four different locations in the maxilla. The specimens were tested in a universal testing machine at a crosshead speed of 1 mm/minute until fracture occurred. The failure types were analyzed and further categorized as irreparable (Type 1) or reparable (Type 2). No significant difference was found between different abutment types. Only for the position of the maxillary central incisor, composite resin crowns on PEEK temporary abutments showed significantly lower (p resin crowns (75 out of 104), followed by screw loosening (18 out of 104). According to reparability, the majority of the specimens were classified as Type 1 (82 out of 104). Type 2 failures were not often observed (22 out of 104). Provisional crowns on PEEK abutments showed similar fracture strength as titanium temporary abutments except for central incisors. Maxillary right central incisor composite resin crowns on PEEK temporary abutments fractured below the mean anterior masticatory loading forces reported to be approximately 206 N. © 2010 Wiley Periodicals, Inc.

  15. Survival and complications of zirconia-based fixed dental prostheses: a systematic review.

    Science.gov (United States)

    Raigrodski, Ariel J; Hillstead, Matthew B; Meng, Graham K; Chung, Kwok-Hung

    2012-03-01

    Evidence is limited on the efficacy of zirconia-based fixed dental prostheses. The purpose of this systemic review was to assess zirconia-based FDPs in terms of survival and complications. Searches performed in PubMed databases were enriched by hand searches to identify suitable publications. The keywords used were: "zirconia" and "fixed dental prosthesis," "zirconia" and "crown," "zirconia" and "fixed partial denture" and "humans," "zirconia" and "crown" and "humans," "crown" and "all-ceramics," and "fixed partial denture" and "all-ceramics". Titles and abstracts were read to identify literature that fulfilled the inclusion criteria. Only peer reviewed clinical studies published in the English language from January 1999 through June 2011 were included. Twelve clinical studies based on zirconia, framework design, and porcelain veneering technique met the inclusion criteria. Of the studies identified, 1 was a randomized clinical study with 3-year follow-up results; the others were cohort prospective studies. Clinical complications included chipping of veneering porcelain, abutment failure, and framework fracture. One study investigated pressed ceramics as the veneering material and found no chipping of veneering porcelain after 3 years. Short term clinical data suggest that zirconia-based fixed dental prostheses may serve as an alternative to metal ceramic fixed dental prostheses in the anterior and posterior dentition. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  16. Partial model checking

    DEFF Research Database (Denmark)

    Andersen, Henrik Reif

    1995-01-01

    A major obstacle in applying finite-state model checking to the verification of large systems is the combinatorial explosion of the state space arising when many loosely coupled parallel processes are considered. The problem also known as the state-explosion problem has been attacked from various...... sides. This paper presents a new approach based on partial model checking where parts of the concurrent system are gradually removed while transforming the specification accordingly. When the intermediate specifications constructed in this manner can be kept small, the state-explosion problem is avoided...

  17. Partial differential equations

    CERN Document Server

    Agranovich, M S

    2002-01-01

    Mark Vishik's Partial Differential Equations seminar held at Moscow State University was one of the world's leading seminars in PDEs for over 40 years. This book celebrates Vishik's eightieth birthday. It comprises new results and survey papers written by many renowned specialists who actively participated over the years in Vishik's seminars. Contributions include original developments and methods in PDEs and related fields, such as mathematical physics, tomography, and symplectic geometry. Papers discuss linear and nonlinear equations, particularly linear elliptic problems in angles and gener

  18. Partially ordered algebraic systems

    CERN Document Server

    Fuchs, Laszlo

    2011-01-01

    Originally published in an important series of books on pure and applied mathematics, this monograph by a distinguished mathematician explores a high-level area in algebra. It constitutes the first systematic summary of research concerning partially ordered groups, semigroups, rings, and fields. The self-contained treatment features numerous problems, complete proofs, a detailed bibliography, and indexes. It presumes some knowledge of abstract algebra, providing necessary background and references where appropriate. This inexpensive edition of a hard-to-find systematic survey will fill a gap i

  19. Generalized Partial Volume

    DEFF Research Database (Denmark)

    Darkner, Sune; Sporring, Jon

    2011-01-01

    Mutual Information (MI) and normalized mutual information (NMI) are popular choices as similarity measure for multimodal image registration. Presently, one of two approaches is often used for estimating these measures: The Parzen Window (PW) and the Generalized Partial Volume (GPV). Their theoret...... of view as well as w.r.t. computational complexity. Finally, we present algorithms for both approaches for NMI which is comparable in speed to Sum of Squared Differences (SSD), and we illustrate the differences between PW and GPV on a number of registration examples....

  20. Partial differential equations

    CERN Document Server

    Levine, Harold

    1997-01-01

    The subject matter, partial differential equations (PDEs), has a long history (dating from the 18th century) and an active contemporary phase. An early phase (with a separate focus on taut string vibrations and heat flow through solid bodies) stimulated developments of great importance for mathematical analysis, such as a wider concept of functions and integration and the existence of trigonometric or Fourier series representations. The direct relevance of PDEs to all manner of mathematical, physical and technical problems continues. This book presents a reasonably broad introductory account of the subject, with due regard for analytical detail, applications and historical matters.

  1. Elliptic partial differential equations

    CERN Document Server

    Han, Qing

    2011-01-01

    Elliptic Partial Differential Equations by Qing Han and FangHua Lin is one of the best textbooks I know. It is the perfect introduction to PDE. In 150 pages or so it covers an amazing amount of wonderful and extraordinary useful material. I have used it as a textbook at both graduate and undergraduate levels which is possible since it only requires very little background material yet it covers an enormous amount of material. In my opinion it is a must read for all interested in analysis and geometry, and for all of my own PhD students it is indeed just that. I cannot say enough good things abo

  2. Partial differential equations

    CERN Document Server

    Sloan, D; Süli, E

    2001-01-01

    /homepage/sac/cam/na2000/index.html7-Volume Set now available at special set price ! Over the second half of the 20th century the subject area loosely referred to as numerical analysis of partial differential equations (PDEs) has undergone unprecedented development. At its practical end, the vigorous growth and steady diversification of the field were stimulated by the demand for accurate and reliable tools for computational modelling in physical sciences and engineering, and by the rapid development of computer hardware and architecture. At the more theoretical end, the analytical insight in

  3. Fixed telephony evolution at CERN

    CERN Multimedia

    CERN. Geneva

    2015-01-01

    The heart of CERN’s telephony infrastructure consists of the Alcatel IP-PBX that links CERN’s fixed line phones, Lync softphones and CERN’s GSM subscribers to low-cost local and international telephony services. The PABX infrastructure also supports the emergency “red telephones” in the LHC tunnel and provides vital services for the Fire and Rescue Service and the CERN Control Centre. Although still reliable, the Alcatel hardware is increasingly costly to maintain and looking increasingly outmoded in a market where open source solutions are increasingly dominant. After presenting an overview of the Alcatel PABX and the services it provides, including innovative solutions such as the Closed User Group for our mobile telephony services, we present a possible architecture for a software based system designed to meet tomorrow’s communication needs and describe how the introduction of open-source call routers based on the SIP protocol and Session Border Controllers (SBC) could foster the introduction...

  4. Experts' Understanding of Partial Derivatives Using the Partial Derivative Machine

    Science.gov (United States)

    Roundy, David; Weber, Eric; Dray, Tevian; Bajracharya, Rabindra R.; Dorko, Allison; Smith, Emily M.; Manogue, Corinne A.

    2015-01-01

    Partial derivatives are used in a variety of different ways within physics. Thermodynamics, in particular, uses partial derivatives in ways that students often find especially confusing. We are at the beginning of a study of the teaching of partial derivatives, with a goal of better aligning the teaching of multivariable calculus with the needs of…

  5. Common fixed points for weakly compatible maps

    Indian Academy of Sciences (India)

    Springer Verlag Heidelberg #4 2048 1996 Dec 15 10:16:45

    In 1976, Jungck [4] proved a common fixed point theorem for commuting maps generalizing the Banach's fixed point theorem, which states that, 'let (X, d) be a complete metric space. If T satisfies d(Tx,Ty) ≤ kd(x,y) for each x,y ∈ X where 0 ≤ k < 1, then T has a unique fixed point in X'. This theorem has many applications, ...

  6. Gauge fixing and the gibbs phenomenon

    Science.gov (United States)

    Mandula, Jeffrey E.

    1999-03-01

    We address the question of why global gauge fixing, specifically to the lattice Landau gauge, becomes an extremely lengthy process for large lattices. We construct an artificial "gauge-fixing" problem which has the essential features encountered in actuality. In the limit in which the size of the system to be gauge fixed becomes infinite, the problem becomes equivalent to finding a series expansion in functions which are related to the Jacobi polynomials. The series converges slowly, as expected. It also converges non-uniformly, which is an observed characteristic of gauge fixing. In the limiting example, the non-uniformity arises through the Gibbs phenomenon.

  7. Gauge fixing and the gibbs phenomenon

    Energy Technology Data Exchange (ETDEWEB)

    Mandula, Jeffrey E

    1999-03-01

    We address the question of why global gauge fixing, specifically to the lattice Landau gauge, becomes an extremely lengthy process for large lattices. We construct an artificial 'gauge-fixing' problem which has the essential features encountered in actuality. In the limit in which the size of the system to be gauge fixed becomes infinite, the problem becomes equivalent to finding a series expansion in functions which are related to the Jacobi polynomials. The series converges slowly, as expected. It also converges non-uniformly, which is an observed characteristic of gauge fixing. In the limiting example, the non-uniformity arises through the Gibbs phenomenon.

  8. Fixed point theorems in spaces and -trees

    Directory of Open Access Journals (Sweden)

    Kirk WA

    2004-01-01

    Full Text Available We show that if is a bounded open set in a complete space , and if is nonexpansive, then always has a fixed point if there exists such that for all . It is also shown that if is a geodesically bounded closed convex subset of a complete -tree with , and if is a continuous mapping for which for some and all , then has a fixed point. It is also noted that a geodesically bounded complete -tree has the fixed point property for continuous mappings. These latter results are used to obtain variants of the classical fixed edge theorem in graph theory.

  9. Dapsone-associated fixed drug eruption.

    Science.gov (United States)

    Garcia, Daniel; Cohen, Philip R

    2017-07-01

    Dapsone is a sulfone drug used to treat infectious conditions and also numerous dermatologic diseases. Fixed drug eruption is a distinctive adverse cutaneous reaction associated with the initial administration and subsequent delivery of a specific agent. Areas covered: The authors preformed a literature search using the following keywords: dapsone, fixed drug eruption, and adverse cutaneous drug reaction. Bibliographies were also reviewed for pertinent articles. The results were combed for relevant papers and reviewed. Articles pertaining to dapsone-associated fixed drug eruption were included. Expert commentary: The majority of cases of dapsone-associated fixed drug eruption in the literature come from Africa or India where there is a high prevalence of patients treated for leprosy. Characteristics of these cases are similar to fixed drug eruption described in the western literature, with differences in frequency of multiple versus solitary lesions. Dapsone-associated fixed drug eruption should be considered when reviewing the drug history of a patient with fixed drug eruption. In the case of darker pigmented individuals, multiple fixed drug eruption lesions may be more common. Multiple lesions may mimic Kaposi's sarcoma in human immunodeficiency virus positive patients. Dapsone-associated fixed drug eruption should be considered in the differential diagnosis of multiple hyperpigmented lesions.

  10. Fixed point theorem utilizing operators and functionals

    Directory of Open Access Journals (Sweden)

    Douglas Anderson

    2012-02-01

    Full Text Available This paper presents a fixed point theorem utilizing operators and functionals in the spirit of the original Leggett-Williams fixed point theorem which is void of any invariance-like conditions. The underlying sets in the Leggett-Williams fixed point theorem that were defined using the total order of the real numbers are replaced by sets that are defined using an ordering generated by a border-symmetric set, that is, the sets that were defined using functionals in the original Leggett-Williams fixed point theorem are replaced by sets that are defined using operators.

  11. Flow Modelling for partially Cavitating Two-dimensional Hydrofoils

    DEFF Research Database (Denmark)

    Krishnaswamy, Paddy

    2001-01-01

    The present work addresses te computational analysis of partial sheet hydrofoil cavitation in two dimensions. Particular attention is given to the method of simulating the flow at the end of the cavity. A fixed-length partially cavitating panel method is used to predict the height of the re......-entrant jet, using the values of the cavitation number and the drag coefficient. The jet surface is subsequently constructed and inclued in an updated cavity shape. At the same time, a source singularity is introduced in the fluid domain to account for the mass flux through the part of the domain boundary...... represented by the re-entrant jet surface. Further iterations are performed for fixed cavitation number on the cavity with a re-entrant jet cavity termination model. This model is seen to produce good results and displays quick convergence. A validation is accomplished by conducting a parametric analysis...

  12. Furnace brazing under partial vacuum

    Science.gov (United States)

    Mckown, R. D.

    1979-01-01

    Brazing furnace utilizing partial-vacuum technique reduces tooling requirements and produces better bond. Benefit in that partial vacuum helps to dissociate metal oxides that inhibit metal flow and eliminates heavy tooling required to hold parts together during brazing.

  13. Longevity of fiber-reinforced composite fixed partial dentures (FRC FPD)-Systematic review.

    Science.gov (United States)

    Ahmed, Khaled E; Li, Kar Yan; Murray, Colin A

    2017-06-01

    to assess FRC FPDs longevity through systematically reviewing contemporary clinical evidence. Population investigated comprised patients requiring replacement of a single missing anterior/posterior tooth. Intervention was FRC FPDs. No control/comparison selected. Outcome was longevity of FRC FPDs. The focus question was: 'What is the longevity of FRC FPDs used to replace one anterior or posterior tooth in patients?' Randomised, non-randomised, controlled, prospective and retrospective clinical studies were included. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses were applied. The Overall Strength of Clinical Recommendation (OSCR) was assessed using the Strength of Recommendation Taxonomy system. Survival of FPDs was assessed using the Kaplan-Meier method. Analysis of FPD-survival according to location and occurrence of different failures was performed using Logrank and Chi-square testing. PubMed, MEDLINE, and Web of Science databases were searched between January 2007 and December 2015. Nine studies were included, involving placement of 592 FRC FPDs in 463 patients. Follow-up periods ranged between 2 months and 8 years. Kaplan-Meier overall survival probability was 94.5% (95%C.I: 92.5%-96.5%) at 4.8 years. There was no significant difference in survival probability of anterior versus posterior FRC FPDs (P=0.278). Veneering material fracture/delamination occurred significantly more than other types of failures (Ps<0.05). A meta-analysis could not be performed. OSCR was moderate. FRC FPDs demonstrated high overall survival with predictable performance outcomes. However, long-term performance remains unclear. FRC FPDs are viable medium-term management alternatives for replacing single anterior or posterior teeth in patients. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Indications and potential of bonded metal-ceramic fixed partial dentures.

    Science.gov (United States)

    Dietschi, D

    2000-01-01

    Recent progress in restorative dentistry has dramatically modified contemporary treatment concepts, which are typified by the preservation of healthy tissues, recognition of aesthetic expectations, and the search for simplified prosthetic solutions. While this shift in focus has justified the increasing interest in implantology, it has also resulted in the expansion of adhesive and conservative treatment options. This article reviews the various means available to replace missing anterior teeth, as well as the periodontal and surgical procedures that are associated with the optimization of biological, functional, and aesthetic results.

  15. Adhesive crowns and fixed partial dentures fabricated of ceromer/FRC: clinical and laboratory procedures.

    Science.gov (United States)

    Krejci, I; Boretti, R; Giezendanner, P; Lutz, F

    1998-05-01

    Ceramic optimized polymer and fiber-reinforced composite materials represent a significant development in prosthetic dentistry. When utilized in conjunction with adhesive luting techniques, exceptionally conservative crown and bridge restorations may be achieved. This article discusses utilization of these materials in inlay and onlay restorations, as well as clinical and laboratory procedures for fabrication, preparation, and seating of adhesive crown and bridge restorations. The initial results of restorations utilizing these innovative materials are presented.

  16. Tutorial on Online Partial Evaluation

    Directory of Open Access Journals (Sweden)

    William R. Cook

    2011-09-01

    Full Text Available This paper is a short tutorial introduction to online partial evaluation. We show how to write a simple online partial evaluator for a simple, pure, first-order, functional programming language. In particular, we show that the partial evaluator can be derived as a variation on a compositionally defined interpreter. We demonstrate the use of the resulting partial evaluator for program optimization in the context of model-driven development.

  17. Factors influencing bonding fixed restorations

    Directory of Open Access Journals (Sweden)

    Medić Vesna

    2008-01-01

    Full Text Available INTRODUCTION Crown displacement often occurs because the features of tooth preparations do not counteract the forces directed against restorations. OBJECTIVE The purpose of this study was to evaluate the effect of preparation designs on retention and resistance of fixed restorations. METHOD The study was performed on 64 differently sized stainless steel dies. Also, caps which were used for evaluated retention were made of stainless steel for each die. After cementing the caps on experimental dies, measuring of necessary tensile forces to separate cemented caps from dies was done. Caps, which were made of a silver-palladium alloy with a slope of 60° to the longitudinal axis formed on the occlusal surface, were used for evaluating resistance. A sudden drop in load pressure recorded by the test machine indicated failure for that cap. RESULTS A significant difference was found between the tensile force required to remove the caps from the dies with different length (p<0.05 and different taper (p<0.01. The greatest retentive strengths (2579.2 N and 2989.8 N were noticed in experimental dies with the greatest length and smallest taper. No statistically significant (p>0.05 differences were found between tensile loads for caps cemented on dies with different diameter. Although there was an apparent slight increase in resistance values for caps on dies with smaller tapers, the increase in resistance for those preparation designs was not statistically significant. There was a significant difference among the resistance values for caps on dies with different length (p<0.01 and diameter (p<0.05. CONCLUSION In the light of the results obtained, it could be reasonably concluded that retention and resistance of the restoration is in inverse proportion to convergence angle of the prepared teeth. But, at a constant convergence angle, retention and resistance increase with rising length and diameter.

  18. [Factors influencing bonding fixed restorations].

    Science.gov (United States)

    Medić, Vesna; Obradović-Djuricić, Kosovka

    2008-01-01

    Crown displacement often occurs because the features of tooth preparations do not counteract the forces directed against restorations. The purpose of this study was to evaluate the effect of preparation designs on retention and resistance of fixed restorations. The study was performed on 64 differently sized stainless steel dies. Also, caps which were used for evaluated retention were made of stainless steel for each die. After cementing the caps on experimental dies, measuring of necessary tensile forces to separate cemented caps from dies was done. Caps, which were made of a silver-palladium alloy with a slope of 600 to the longitudinal axis formed on the occlusal surface, were used for evaluating resistance. A sudden drop in load pressure recorded by the test machine indicated failure for that cap. A significant difference was found between the tensile force required to remove the caps from the dies with different length (p different taper (p 0.05) differences were found between tensile loads for caps cemented on dies with different diameter. Although there was an apparent slight increase in resistance values for caps on dies with smaller tapers, the increase in resistance for those preparation designs was not statistically significant. There was a significant difference among the resistance values for caps on dies with different length (p < 0.01) and diameter (p < 0.05). In the light of the results obtained, it could be reasonably concluded that retention and resistance of the restoration is in inverse proportion to convergence angle of the prepared teeth. But, at a constant convergence angle, retention and resistance increase with rising length and diameter.

  19. Type-Directed Partial Evaluation

    DEFF Research Database (Denmark)

    Danvy, Olivier

    1998-01-01

    Type-directed partial evaluation uses a normalization function to achieve partial evaluation. These lecture notes review its background, foundations, practice, and applications. Of specific interest is the modular technique of offline and online type-directed partial evaluation in Standard ML of ...

  20. Type-Directed Partial Evaluation

    DEFF Research Database (Denmark)

    Danvy, Olivier

    1998-01-01

    Type-directed partial evaluation uses a normalization function to achieve partial evaluation. These lecture notes review its background, foundations, practice, and applications. Of specific interest is the modular technique of offline and online type-directed partial evaluation in Standard ML...

  1. Fundamental partial compositeness

    CERN Document Server

    Sannino, Francesco

    2016-01-01

    We construct renormalizable Standard Model extensions, valid up to the Planck scale, that give a composite Higgs from a new fundamental strong force acting on fermions and scalars. Yukawa interactions of these particles with Standard Model fermions realize the partial compositeness scenario. Successful models exist because gauge quantum numbers of Standard Model fermions admit a minimal enough 'square root'. Furthermore, right-handed SM fermions have an SU(2)$_R$-like structure, yielding a custodially-protected composite Higgs. Baryon and lepton numbers arise accidentally. Standard Model fermions acquire mass at tree level, while the Higgs potential and flavor violations are generated by quantum corrections. We further discuss accidental symmetries and other dynamical features stemming from the new strongly interacting scalars. If the same phenomenology can be obtained from models without our elementary scalars, they would reappear as composite states.

  2. Applied partial differential equations

    CERN Document Server

    Logan, J David

    2004-01-01

    This primer on elementary partial differential equations presents the standard material usually covered in a one-semester, undergraduate course on boundary value problems and PDEs. What makes this book unique is that it is a brief treatment, yet it covers all the major ideas: the wave equation, the diffusion equation, the Laplace equation, and the advection equation on bounded and unbounded domains. Methods include eigenfunction expansions, integral transforms, and characteristics. Mathematical ideas are motivated from physical problems, and the exposition is presented in a concise style accessible to science and engineering students; emphasis is on motivation, concepts, methods, and interpretation, rather than formal theory. This second edition contains new and additional exercises, and it includes a new chapter on the applications of PDEs to biology: age structured models, pattern formation; epidemic wave fronts, and advection-diffusion processes. The student who reads through this book and solves many of t...

  3. Fundamental partial compositeness

    Energy Technology Data Exchange (ETDEWEB)

    Sannino, Francesco [CP-Origins and Danish IAS, University of Southern Denmark,Campusvej 55 (Denmark); Strumia, Alessandro [Dipartimento di Fisica dell’Università di Pisa and INFN,Pisa (Italy); Theory Division, CERN,Geneva (Switzerland); Tesi, Andrea [Department of Physics, Enrico Fermi Institute, University of Chicago,Chicago, IL 60637 (United States); Vigiani, Elena [Dipartimento di Fisica dell’Università di Pisa and INFN,Pisa (Italy)

    2016-11-07

    We construct renormalizable Standard Model extensions, valid up to the Planck scale, that give a composite Higgs from a new fundamental strong force acting on fermions and scalars. Yukawa interactions of these particles with Standard Model fermions realize the partial compositeness scenario. Under certain assumptions on the dynamics of the scalars, successful models exist because gauge quantum numbers of Standard Model fermions admit a minimal enough ‘square root’. Furthermore, right-handed SM fermions have an SU(2){sub R}-like structure, yielding a custodially-protected composite Higgs. Baryon and lepton numbers arise accidentally. Standard Model fermions acquire mass at tree level, while the Higgs potential and flavor violations are generated by quantum corrections. We further discuss accidental symmetries and other dynamical features stemming from the new strongly interacting scalars. If the same phenomenology can be obtained from models without our elementary scalars, they would reappear as composite states.

  4. Elliptic partial differential equations

    CERN Document Server

    Volpert, Vitaly

    If we had to formulate in one sentence what this book is about it might be "How partial differential equations can help to understand heat explosion, tumor growth or evolution of biological species". These and many other applications are described by reaction-diffusion equations. The theory of reaction-diffusion equations appeared in the first half of the last century. In the present time, it is widely used in population dynamics, chemical physics, biomedical modelling. The purpose of this book is to present the mathematical theory of reaction-diffusion equations in the context of their numerous applications. We will go from the general mathematical theory to specific equations and then to their applications. Mathematical anaylsis of reaction-diffusion equations will be based on the theory of Fredholm operators presented in the first volume. Existence, stability and bifurcations of solutions will be studied for bounded domains and in the case of travelling waves. The classical theory of reaction-diffusion equ...

  5. Partial pressure gauges

    CERN Document Server

    Peter, G J

    2007-01-01

    The determination of partial pressures in vacuum systems is usually performed by mass spectrometers. The most common type is the QMS. Quadrupole mass spectrometers were developed decades ago and have been used by vacuum specialists as a diagnostic tool since then. In the first part of the paper the principles of these mass spectrometers are briefly reviewed together with the key features of the instruments. This is necessary to operate these instruments. In the second part the boundary conditions which arise from the application as residual gas analyser in UHV/XHV plants are described. These lead to special versions of mass spectrometers. Results obtained with these instruments and typical artefacts in mass spectra obtained in the UHV are discussed.

  6. pH-Dependent solubility and permeability criteria for provisional biopharmaceutics classification (BCS and BDDCS) in early drug discovery.

    Science.gov (United States)

    Varma, Manthena V; Gardner, Iain; Steyn, Stefanus J; Nkansah, Paul; Rotter, Charles J; Whitney-Pickett, Carrie; Zhang, Hui; Di, Li; Cram, Michael; Fenner, Katherine S; El-Kattan, Ayman F

    2012-05-07

    The Biopharmaceutics Classification System (BCS) is a scientific framework that provides a basis for predicting the oral absorption of drugs. These concepts have been extended in the Biopharmaceutics Drug Disposition Classification System (BDDCS) to explain the potential mechanism of drug clearance and understand the effects of uptake and efflux transporters on absorption, distribution, metabolism, and elimination. The objective of present work is to establish criteria for provisional biopharmaceutics classification using pH-dependent passive permeability and aqueous solubility data generated from high throughput screening methodologies in drug discovery settings. The apparent permeability across monolayers of clonal cell line of Madin-Darby canine kidney cells, selected for low endogenous efflux transporter expression, was measured for a set of 105 drugs, with known BCS and BDDCS class. The permeability at apical pH 6.5 for acidic drugs and at pH 7.4 for nonacidic drugs showed a good correlation with the fraction absorbed in human (Fa). Receiver operating characteristic (ROC) curve analysis was utilized to define the permeability class boundary. At permeability ≥ 5 × 10(-6) cm/s, the accuracy of predicting Fa of ≥ 0.90 was 87%. Also, this cutoff showed more than 80% sensitivity and specificity in predicting the literature permeability classes (BCS), and the metabolism classes (BDDCS). The equilibrium solubility of a subset of 49 drugs was measured in pH 1.2 medium, pH 6.5 phosphate buffer, and in FaSSIF medium (pH 6.5). Although dose was not considered, good concordance of the measured solubility with BCS and BDDCS solubility class was achieved, when solubility at pH 1.2 was used for acidic compounds and FaSSIF solubility was used for basic, neutral, and zwitterionic compounds. Using a cutoff of 200 μg/mL, the data set suggested a 93% sensitivity and 86% specificity in predicting both the BCS and BDDCS solubility classes. In conclusion, this study identified

  7. Approximate Equilibrium Problems and Fixed Points

    Directory of Open Access Journals (Sweden)

    H. Mazaheri

    2013-01-01

    Full Text Available We find a common element of the set of fixed points of a map and the set of solutions of an approximate equilibrium problem in a Hilbert space. Then, we show that one of the sequences weakly converges. Also we obtain some theorems about equilibrium problems and fixed points.

  8. Infra-red fixed points in supersymmetry

    Indian Academy of Sciences (India)

    malization group (RG) running of the parameters is dominated by infra-red stable fixed points. Typically, these fixed points are for ratios like Yukawa couplings to the gauge cou- pling, or in the context of supersymmetric models, the supersymmetry breaking trilinear. A-parameter to the gaugino mass, etc. These ratios do not ...

  9. Implant complications and failures: the fixed prosthesis.

    Science.gov (United States)

    Tinsley, D; Watson, C J; Preston, A J

    2002-11-01

    The implant-retained fixed prosthesis has been advocated as an effective restoration offering significant benefits over conventional prosthetics. The success of treatment depends on careful pre-surgical planning and prosthesis design. This paper outlines some common complications encountered during the planning, fabrication and maintenance of both large and small fixed prostheses and suggests how these complications can be minimized.

  10. Fixed-Response Questions with a Difference.

    Science.gov (United States)

    Johnstone, Alex H.; Ambusaidi, Abdullah

    2002-01-01

    Offers three types of fixed-response questions that are designed to overcome drawbacks appearing in the conventional forms of fixed-response questions such as not allowing the examiner to investigate reasoning, background, or prevent guessing. (Contains 14 references.) (Author/YDS)

  11. The price of fixed income market volatility

    CERN Document Server

    Mele, Antonio

    2015-01-01

    Fixed income volatility and equity volatility evolve heterogeneously over time, co-moving disproportionately during periods of global imbalances and each reacting to events of different nature. While the methodology for options-based "model-free" pricing of equity volatility has been known for some time, little is known about analogous methodologies for pricing various fixed income volatilities. This book fills this gap and provides a unified evaluation framework of fixed income volatility while dealing with disparate markets such as interest-rate swaps, government bonds, time-deposits and credit. It develops model-free, forward looking indexes of fixed-income volatility that match different quoting conventions across various markets, and uncovers subtle yet important pitfalls arising from naïve superimpositions of the standard equity volatility methodology when pricing various fixed income volatilities. The ultimate goal of the authors´ efforts is to make interest rate volatility standardization a valuable...

  12. Robot-assisted partial nephrectomy: Superiority over laparoscopic partial nephrectomy.

    Science.gov (United States)

    Shiroki, Ryoichi; Fukami, Naohiko; Fukaya, Kosuke; Kusaka, Mamoru; Natsume, Takahiro; Ichihara, Takashi; Toyama, Hiroshi

    2016-02-01

    Nephron-sparing surgery has been proven to positively impact the postoperative quality of life for the treatment of small renal tumors, possibly leading to functional improvements. Laparoscopic partial nephrectomy is still one of the most demanding procedures in urological surgery. Laparoscopic partial nephrectomy sometimes results in extended warm ischemic time and severe complications, such as open conversion, postoperative hemorrhage and urine leakage. Robot-assisted partial nephrectomy exploits the advantages offered by the da Vinci Surgical System to laparoscopic partial nephrectomy, equipped with 3-D vision and a better degree in the freedom of surgical instruments. The introduction of the da Vinci Surgical System made nephron-sparing surgery, specifically robot-assisted partial nephrectomy, safe with promising results, leading to the shortening of warm ischemic time and a reduction in perioperative complications. Even for complex and challenging tumors, robotic assistance is expected to provide the benefit of minimally-invasive surgery with safe and satisfactory renal function. Warm ischemic time is the modifiable factor during robot-assisted partial nephrectomy to affect postoperative kidney function. We analyzed the predictive factors for extended warm ischemic time from our robot-assisted partial nephrectomy series. The surface area of the tumor attached to the kidney parenchyma was shown to significantly affect the extended warm ischemic time during robot-assisted partial nephrectomy. In cases with tumor-attached surface area more than 15 cm(2) , we should consider switching robot-assisted partial nephrectomy to open partial nephrectomy under cold ischemia if it is imperative. In Japan, a nationwide prospective study has been carried out to show the superiority of robot-assisted partial nephrectomy to laparoscopic partial nephrectomy in improving warm ischemic time and complications. By facilitating robotic technology, robot-assisted partial nephrectomy

  13. Comparison of temperature rise in pulp chamber during polymerization of materials used for direct fabrication of provisional restorations: An in-vitro study.

    Science.gov (United States)

    Khajuria, Rajat R; Madan, Ravi; Agarwal, Swatantra; Gupta, Reecha; Vadavadgi, Sunil V; Sharma, Vikas

    2015-01-01

    The purpose is to compare temperature rise in the pulp chamber during fabrication of provisional crowns using different materials and on different types of teeth using direct technique. An extracted, sound, caries free maxillary central incisor and a mandibular molar were selected for the study and crown preparations of all ceramic and all metal were done on central incisor and mandibular molar, respectively. Materials tested were DPI tooth molding self-curing material and protemp-4. Addition silicone putty was used as a matrix and 80 provisional crowns were fabricated, of which 40 were on central incisor and 40 on mandibular molar. Depending on the type of material used, they were further divided into two subgroups: Each comprising 20 provisional crowns. Temperature readings were recorded using K type of thermocouple with 0.1°C precision digital thermometer. Analysis of variance, Tukey honest significant difference and Kruskall-Wallis H-test. Statistically significant difference exists between two materials tested on the basis of peak temperature achieved and time taken by a particular material to reach peak temperature. Peak temperature achieved was highest for provisional crowns with DPI tooth molding self-curing material on maxillary central incisor (40.39 + 0.46), followed by DPI tooth molding self-curing material on mandibular molar (40.03 + 0.32), protemp-4 on maxillary central incisor (39.46 + 0.26) and least with protemp-4 on mandibular molar (39.09 + 0.33). The time taken to reach peak temperature was almost double in DPI tooth molding self-curing material (5 min) than in protemp-4. Polymethyl methacrylate resin produced higher intra-pulpal rise when compared to newer generation bis-acrylic composite.

  14. The effects of desensitizing resin, resin sealing, and provisional cement on the bond strength of dentin luted with self-adhesive and conventional resincements.

    Science.gov (United States)

    Sailer, Irena; Oendra, Andrea E Hernandez; Stawarczyk, Bogna; Hämmerle, Christoph H F

    2012-04-01

    Self-adhesive resin cements were designed to bond without any pretreatment of dentin. However, pretreatments such as the application of desensitizing resin or the resin sealing of dentin with priming/bonding solutions might influence the bonding quality of these self-adhesive resin cements. Little is known about the effect of dentin pretreatment on the bond quality of self-adhesive resin cements. This study evaluated whether dentin desensitizing or sealing methods influenced the shear bond strength of 1 self-adhesive and 2 conventional resin cements. One-hundred and eighty human molars were assigned to 5 different pretreatment groups: 1) freshly ground dentin, 2) glutaraldehyde/hydroxyethylmethacrylate (HEMA) desensitized dentin (Gluma), 3) contamination of desensitized dentin with provisional cement, 4) sealed dentin (dual bonding technique), and 5) contamination of sealed dentin with provisional cement. The shear bond strength of a self-adhesive resin cement (RelyX Unicem; RXU) and 2 conventional resin cements (Variolink II; VAR, Panavia 21; PAN) was assessed for each pretreatment group (n=12 per cement types). Two-way ANOVA and 1-way ANOVA together with the post hoc Tukey multiple comparison (α=.05) were performed. On freshly ground dentin, PAN exhibited the highest shear bond strength values (Pdentin (Pdentin increased the bond strength of RXU but had no significant effect on VAR or PAN. RXU exhibited the highest mean bond strength after the contamination of resin-sealed dentin by provisional cement. Glutaraldehyde/HEMA treatment and resin sealing of dentin have a beneficial effect on the shear bond strength of self-adhesive resin cement (RXU). Contamination of dentin with provisional cement has no influence on the bond strength of the self-adhesive resin cement (RXU) or VAR but lowered the bond strength of PAN. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  15. Estudio descriptivo de la utilización de los espacios deportivos municipales: perspectiva en el uso de un sistema provisional de indicadores.

    OpenAIRE

    Cuenca Ereú, Federico Ignacio

    2016-01-01

    Este estudio consiste en el desarrollo de un sistema provisional de indicadores que permita la descripción de aspectos evaluativos en relación al uso de instalaciones deportivas. Para su elaboración se han tenido en cuenta los datos suministrados por el Departamento de Deportes del Ayuntamiento de Vitoria-Gasteiz en relación a sus instalaciones de tenis y pádel.

  16. Effects of surface treatment and artificial aging on the shear bond strength of orthodontic brackets bonded to four different provisional restorations.

    Science.gov (United States)

    Al Jabbari, Youssef S; Al Taweel, Sara M; Al Rifaiy, Mohammed; Alqahtani, Mohammed Q; Koutsoukis, Theodoros; Zinelis, Spiros

    2014-07-01

    To evaluate the combined effects of material type, surface treatment, and thermocycling on the bond strength of orthodontic brackets to materials used for the fabrication of provisional crowns. Four materials were included in this study (ProTemp, Trim Plus, Trim II, and Superpont C+B). Sixty cylindrical specimens (1 × 3 cm) were prepared from each material and equally divided into three groups. The first group was ground with silica carbide paper, the second was polished with pumice, and the last group was sandblasted with 50-µm aluminum oxide particles. Stainless-steel maxillary central incisor brackets (Victory Series, 3M) were bonded to the provisional material specimens with Transbond XT light-cured composite resin, and half of the specimens from each group were thermocycled 500 times in 5°C and 55°C water baths. Then the brackets were debonded with shear testing, and the results were statistically analyzed by three-way analysis of variance and Tukey's multiple-comparison tests at α  =  0.05. Adhesive Remnant Index (ARI) was also identified. Before and after thermocycling, ProTemp materials showed the highest shear bond strength with orthodontic brackets (10.3 and 13.1 MPa, respectively). The statistical analysis indicated an interaction among the three independent variables (P < .05) and statistically significant differences in bond strength among provisional materials (P < .001), surface treatments (P < .001), and thermocycling (P < .05). According to the ARI, most groups demonstrated adhesive failure. The provisional material type, surface treatment, and artificial aging have a significant effect on bond strength. Sandblasting treatment exerts a beneficial effect on shear bond strength.

  17. Partially supervised speaker clustering.

    Science.gov (United States)

    Tang, Hao; Chu, Stephen Mingyu; Hasegawa-Johnson, Mark; Huang, Thomas S

    2012-05-01

    Content-based multimedia indexing, retrieval, and processing as well as multimedia databases demand the structuring of the media content (image, audio, video, text, etc.), one significant goal being to associate the identity of the content to the individual segments of the signals. In this paper, we specifically address the problem of speaker clustering, the task of assigning every speech utterance in an audio stream to its speaker. We offer a complete treatment to the idea of partially supervised speaker clustering, which refers to the use of our prior knowledge of speakers in general to assist the unsupervised speaker clustering process. By means of an independent training data set, we encode the prior knowledge at the various stages of the speaker clustering pipeline via 1) learning a speaker-discriminative acoustic feature transformation, 2) learning a universal speaker prior model, and 3) learning a discriminative speaker subspace, or equivalently, a speaker-discriminative distance metric. We study the directional scattering property of the Gaussian mixture model (GMM) mean supervector representation of utterances in the high-dimensional space, and advocate exploiting this property by using the cosine distance metric instead of the euclidean distance metric for speaker clustering in the GMM mean supervector space. We propose to perform discriminant analysis based on the cosine distance metric, which leads to a novel distance metric learning algorithm—linear spherical discriminant analysis (LSDA). We show that the proposed LSDA formulation can be systematically solved within the elegant graph embedding general dimensionality reduction framework. Our speaker clustering experiments on the GALE database clearly indicate that 1) our speaker clustering methods based on the GMM mean supervector representation and vector-based distance metrics outperform traditional speaker clustering methods based on the “bag of acoustic features” representation and statistical

  18. Provisional Tic Disorder: What to tell parents when their child first starts ticcing [version 1; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Kevin J Black

    2016-04-01

    Full Text Available The child with recent onset of tics is a common patient in a pediatrics or child neurology practice. If the child’s first tic was less than a year in the past, the diagnosis is usually Provisional Tic Disorder (PTD. Published reviews by experts reveal substantial consensus on prognosis in this situation: the tics will almost always disappear in a few months, having remained mild while they lasted. Surprisingly, however, the sparse existing data may not support these opinions. PTD may have just as much importance for science as for clinical care. It provides an opportunity to prospectively observe the spontaneous remission of tics. Such prospective studies may aid identification of genes or biomarkers specifically associated with remission rather than onset of tics. A better understanding of tic remission may also suggest novel treatment strategies for Tourette syndrome, or may lead to secondary prevention of tic disorders. This review summarizes the limited existing data on the epidemiology, phenomenology, and outcome of PTD, highlights areas in which prospective study is sorely needed, and proposes that tic disorders may completely remit much less often than is generally believed.

  19. Evaluation of the flexural strength and microhardness of provisional crown and bridge materials fabricated by different methods.

    Science.gov (United States)

    Digholkar, Shruti; Madhav, V N V; Palaskar, Jayant

    2016-01-01

    The purpose of this study was to evaluate and compare the flexural strength and microhardness of provisional restorative materials fabricated utilizing rapid prototyping (RP), Computer Assisted Designing and Computer Assisted Milling (CAD-CAM) and conventional method. Twenty specimens of dimensions 25 mm × 2 mm × 2 mm (ADA-ANSI specification #27) were fabricated each using: (1) Three dimensional (3D) printed light-cured micro-hybrid filled composite by RP resin group, (2) a milled polymethyl methacrylate (CH) using CAD-CAM (CC resin group), and (3) a conventionally fabricated heat activated polymerized CH resin group. Flexural strength and microhardness were measured and values obtained were evaluated. The measured mean flexural strength values (MegaPascals) were 79.54 (RP resin group), 104.20 (CC resin group), and 95.58 (CH resin group). The measured mean microhardness values (Knoop hardness number) were 32.77 (RP resin group), 25.33 (CC resin group), and 27.36 (CH resin group). The analysis of variance (ANOVA) test shows that there is statistically significant difference in the flexural strength values of the three groups (P microhardness values of the three groups was statistically significant according to ANOVA as well as the intergroup comparison done using the Tukey's HSD (post hoc) test (P microhardness.

  20. Implant-supported fixed prosthesis in a hypohidrotic ectodermal dysplasia patient: a case report with 3 years follow-up and review of the literature.

    Science.gov (United States)

    Stern, J Kobi; Hansen, Trisha; Frankel, Joel; Evian, Cyril

    2014-08-01

    Ectodermal dysplasia (ED) is a rare inherited disorder that affects structures derived from embryonic ectoderm. Due to associated ridge deficiency, and anodontia found in these patients, multiple surgeries are often indicated before replacement of missing teeth with implants, resulting in increased morbidity and treatment time. In this case report, a 31-year-old woman was transitioned from failing tooth-supported fixed restorations to a fully implant-supported fixed prosthesis using immediate implants and narrow diameter implants (NDI). By using some of her existing dentition to support the provisional restorations while osseointegration took place, the patient was able to retain function during treatment. Full-fixed implant-supported prostheses were delivered, providing an esthetic and functional outcome that has been maintained for 3 years. In ED patients, NDI together with immediate implant placement can be used successfully to support a complete fixed restoration and should be considered as an alternative to major reconstruction surgeries. Key factors associated with increased predictability are discussed together with a review of the literature.

  1. Characteristic Studies of Micron Zinc Particle Hydrolysis in a Fixed Bed Reactor

    Directory of Open Access Journals (Sweden)

    Lv Ming

    2015-09-01

    Full Text Available Zinc fuel is considered as a kind of promising energy sources for marine propeller. As one of the key steps for zinc marine energy power system, zinc hydrolysis process had been studied experimentally in a fixed bed reactor. In this study, we focus on the characteristics of micron zinc particle hydrolysis. The experimental results suggested that the steam inner diffusion is the controlling step of accumulative zinc particles hydrolysis reaction at a relative lower temperature and a relative higher water partial pressure. In other conditions, the chemical reaction kinetics was the controlling step. And two kinds of chemical reaction kinetics appeared in experiments: the surface reaction and the gas-gas reaction. The latter one occurs usually for larger zinc particles and high reaction temperature. Temperature seems to be one of the most important parameters for the dividing of different reaction mechanisms. Several parameters of the hydrolysis process including heating rate, water partial pressure, the particle size and temperature were also studied in this paper. Results show that the initial reaction temperature of zinc hydrolysis in fixed bed is about 410°C. And the initial reaction temperature increases as the heating rate increases and as the water partial pressure decreases. The total hydrogen yield increases as the heating rate decreases, as the water partial pressure increases, as the zinc particle size decreases, and as the reaction temperature increases. A hydrogen yield of more than 81.5% was obtained in the fixed bed experiments.

  2. Optimizing anterior esthetics of a single-tooth implant through socket augmentation and immediate provisionalization: A case report with 7-year follow-up

    Directory of Open Access Journals (Sweden)

    Po-Sung Fu

    2012-10-01

    Full Text Available Tooth extraction inevitably accompanies alveolar ridge resorption with loss of pre-existing tissue morphology. Replacing missing teeth with dental implants has become popular, but restoring anterior teeth with implant-supported restorations is a technique-sensitive task and poses challenges for dentists. With the progress of implant dentistry, the demand for optimal esthetics has become linked with the desire for faster, easier techniques that shorten treatment time and also satisfy patients. Immediate provisionalization of a single-tooth implant provides significant benefits compared with traditional delayed protocols, such as aiding the contouring of peri-implant soft tissue and enhancing patient comfort and satisfaction. This article describes a meticulous approach to a hopeless maxillary central incisor with root fracture. The defect in the extraction socket was reconstructed using autogenous bone harvested from the chin. Four months later, an implant was installed and immediately restored. After another healing period of 6 months, the peri-implant soft tissue had been shaped and matured according to the contours of the provisional restoration. The emergence profile was used to duplicate the definitive restoration. Peri-implant esthetics was achieved through socket augmentation and immediate provisionalization of the implant. This treatment modality attained predictable and maintainable outcomes, both functionally and esthetically.

  3. Instalación inmediata de prótesis provisionales en la reapertura de implantes Immediate instalation of provisional protheses in implant reopening

    Directory of Open Access Journals (Sweden)

    Alejandro Munõz Chávez

    2007-03-01

    Full Text Available El estudio de las técnicas para alcamzar una estética en el seguimiento anterior cuando se utilizan implantes osteointegrados es de gran importancia. Se realizó una revisión de la literatura con el objetivo de comparar la eficiencia y conveniencia de la instalación de prótesis provisionales inmediatamente en la reapertura de los implantes osteointegrados en relación con el tiempo establecido (uso de cicatrizadores estandarizados y cicatrizadores con perfil de emergencia arbitrado. La prótesis provisional inmediata en la fase de reapertura propicia la restauración del contorno de la encía más rápidamente cuando se compara con el uso de cicatrizadores sin necesidad de fases intermediarias.The study of techniques to reach aesthetics in the anterior region when using osseointegrated implants is of great importance. A literature review was made to compare effivciency and suitability of immediate provisionalization in re-opening of osseointegrated implants with respect to the set time (use of standardized cicatrizants and emergency profile cicatrizants. Immediate provisional denture in the phase of re-opening makes the restoration of the gingival contourn quicker when compared to the use of cicatrizants without intermediate phases required.

  4. [Post traumatic partial seizures].

    Science.gov (United States)

    Carvajal, P; Almárcegui, C; Pablo, M J; Peralta, P; Bernal, M; Valdizán, J R

    Post traumatic epilepsy represents 4% of the prevalence of the disorder and is one of the sequelas which is most difficult to prevent. Risk factors have been described to predict the appearance of seizures. A seven year old boy with a severe head injury was admitted to the Intensive Care Unit. On neuroimaging studies there were multiple foci of contusion, mainly in the left hemisphere, and blood in the III and IV ventricles and frontal horn of the left lateral ventricle. The patient had severe sequelae of head injury with a right spastic hemiplegia and hemiparesia with hypertony of the left side, together with complete blindness of both eyes due to bilateral atrophy of the optic nerve. Serial EEG were done, in which a recording showed alternating periods of hypervoltage grapho elements superimposed on a trace of very low voltage, with continuous activity of low voltage and low frequency. There were no grapho elements with acute morphology. However, the patient had a first partial seizure a year and a half after his head injury. On the EEG an epileptogenic focus was identified in the left hemisphere. Within two years of his head injury he had seven seizures. He had not received prophylactic antiepileptic treatment after the head injury. We report a case of epilepsy secondary to a head injury, in which the first seizure occurred one and a half years after injury. In view of the risk factors, we discuss whether prophylactic anti epileptic treatment might have been beneficial.

  5. Management of severe partial hypodontia: case report.

    Science.gov (United States)

    Caldo-Teixeira, Angela Scarparo; Puppin-Rontani, Regina Maria

    2003-01-01

    Hypodontia is characterized by partial or total congenital missing of one or more teeth, on one or both dentitions. Heredity is the main etiological factor and the principal clinical features are reduction on number, size and form of teeth, and late eruption. Removable partial prosthesis, fixed prosthesis, overdentures and adhesive prosthesis are alternative treatments; and the indication is type dependent. The aim of this study was to describe the clinical case of an eleven-year-old child with eight missing permanent teeth of idiopathic etiology. The patient had facial and skeletal symmetry, normal development and was not related to any syndrome. Clinical characteristics: permanent teeth with good periodontal conditions (16, 12, 11, 21, 22, 26, 36, 31, 42, 46), primary teeth (53, 63, 64, 73, 83); overbite and microdontia on teeth 12 and 22. The treatment plan was done initially by documenting of the case for teeth analysis (study casting models, periapicals and panoramic x-rays, and photographs), and followed by the exodontics of teeth 73 and 83. A removable appliance in autocured acrylic resin, using teeth in acrylic for maintenance of functional space and occlusion was planned and carried out. An anterior track for vertical dimension gain was used because of his accentuated overbite. The patient will be monitored until the end of the craniofacial growth, when it will be again evaluated and forwarded for the final oral rehabilitation. Hypodontia diagnosis and management should be performed as early as possible not to interfere with the craniofacial development of the child.

  6. Evaporation from partially covered water surfaces

    Science.gov (United States)

    Assouline, S.; Narkis, K.; Or, D.

    2010-10-01

    Evaporative losses from large water bodies may exceed 20% of water used in irrigated agriculture, with losses from reservoirs estimated at 50% of storage capacity. Prominent among proposed methods to curtail these evaporative losses are various forms of partial covers placed over water surfaces. Studies show that evaporation through perforated covers and from partially covered water surfaces exhibit nonlinear behavior, where rates of water loss are not proportional to uncovered surface fraction and are significantly affected by opening size and relative spacing. We studied evaporation from small water bodies under various perforated covers, extending the so-called diameter law to opening sizes in the range of 10-5 to 10-1 m. Contradicting claims concerning effects of openings and their arrangement on performance of evaporation barriers are analyzed on per opening and on per area mass losses. Our results help reconcile some classical findings invoking detailed pore-scale diffusion and simple temperature-based energetic behaviors. For fixed relative spacing, area-averaged evaporative flux density remains nearly constant across several orders of magnitude variations in opening size. For the scale of the experimental setup, we predict relative evaporation reduction efficiency for various configurations of perforated evaporation barriers.

  7. Fixed-point adiabatic quantum search

    Science.gov (United States)

    Dalzell, Alexander M.; Yoder, Theodore J.; Chuang, Isaac L.

    2017-01-01

    Fixed-point quantum search algorithms succeed at finding one of M target items among N total items even when the run time of the algorithm is longer than necessary. While the famous Grover's algorithm can search quadratically faster than a classical computer, it lacks the fixed-point property—the fraction of target items must be known precisely to know when to terminate the algorithm. Recently, Yoder, Low, and Chuang [Phys. Rev. Lett. 113, 210501 (2014), 10.1103/PhysRevLett.113.210501] gave an optimal gate-model search algorithm with the fixed-point property. Previously, it had been discovered by Roland and Cerf [Phys. Rev. A 65, 042308 (2002), 10.1103/PhysRevA.65.042308] that an adiabatic quantum algorithm, operating by continuously varying a Hamiltonian, can reproduce the quadratic speedup of gate-model Grover search. We ask, can an adiabatic algorithm also reproduce the fixed-point property? We show that the answer depends on what interpolation schedule is used, so as in the gate model, there are both fixed-point and non-fixed-point versions of adiabatic search, only some of which attain the quadratic quantum speedup. Guided by geometric intuition on the Bloch sphere, we rigorously justify our claims with an explicit upper bound on the error in the adiabatic approximation. We also show that the fixed-point adiabatic search algorithm can be simulated in the gate model with neither loss of the quadratic Grover speedup nor of the fixed-point property. Finally, we discuss natural uses of fixed-point algorithms such as preparation of a relatively prime state and oblivious amplitude amplification.

  8. Fixed point results for G-α-contractive maps with application to boundary value problems.

    Science.gov (United States)

    Hussain, Nawab; Parvaneh, Vahid; Roshan, Jamal Rezaei

    2014-01-01

    We unify the concepts of G-metric, metric-like, and b-metric to define new notion of generalized b-metric-like space and discuss its topological and structural properties. In addition, certain fixed point theorems for two classes of G-α -admissible contractive mappings in such spaces are obtained and some new fixed point results are derived in corresponding partially ordered space. Moreover, some examples and an application to the existence of a solution for the first-order periodic boundary value problem are provided here to illustrate the usability of the obtained results.

  9. Statistics of narrow-band partially polarized light

    Science.gov (United States)

    Charnotskii, Mikhail

    2017-09-01

    A complete single-point statistical description of a narrow-band partially polarized optical field is developed in terms of the 2D period-averaged probability density function (PA-PDF) of the electrical field vector. This statistic can be measured using the coherent (heterodyne) detection. PA-PDF carries more information about the partially polarized light than the traditional Stokes vector. For a simple Gaussian partially polarized field the PA-PDF depends on 13 real parameters in contrast to the four parameters of the Stokes vector or coherence tensor. We show on several examples that the polarization state of the wave, as described by PA-PDF can vary significantly even while Stokes vector remains fixed.

  10. Fixed target issues for the Tevatron Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Stefanski, R.

    1988-08-29

    The Tevatron Upgrade poses some interesting prospects for the Fixed-Target program if an option to extract the high energy proton beam is preserved. This paper presents a summary of the advantages of increased energy for fixed target experiments, and evaluates some of the more challenging technical issues. In particular, Bottom production, muon and neutrino interactions, and polarized /bar p/ experiments would benefit substantially from a higher energy primary beam. The new Main Injector will also be important for fixed target experiments as a source for test beams and intense kaon and neutrino beams. 4 refs., 2 tabs.

  11. About Applications of the Fixed Point Theory

    Directory of Open Access Journals (Sweden)

    Bucur Amelia

    2017-06-01

    Full Text Available The fixed point theory is essential to various theoretical and applied fields, such as variational and linear inequalities, the approximation theory, nonlinear analysis, integral and differential equations and inclusions, the dynamic systems theory, mathematics of fractals, mathematical economics (game theory, equilibrium problems, and optimisation problems and mathematical modelling. This paper presents a few benchmarks regarding the applications of the fixed point theory. This paper also debates if the results of the fixed point theory can be applied to the mathematical modelling of quality.

  12. Fixed point algebras for easy quantum groups

    DEFF Research Database (Denmark)

    Gabriel, Olivier; Weber, Moritz

    2016-01-01

    Compact matrix quantum groups act naturally on Cuntz algebras. The first author isolated certain conditions under which the fixed point algebras under this action are Kirchberg algebras. Hence they are completely determined by their K-groups. Building on prior work by the second author,we prove...... that free easy quantum groups satisfy these conditions and we compute the K-groups of their fixed point algebras in a general form. We then turn to examples such as the quantum permutation group S+ n,the free orthogonal quantum group O+ n and the quantum reflection groups Hs+ n. Our fixed point...

  13. Six-implant-supported immediate fixed rehabilitation of atrophic edentulous maxillae with tilted distal implants.

    Science.gov (United States)

    Wentaschek, S; Hartmann, S; Walter, C; Wagner, W

    2017-12-01

    The aim of this retrospective study was to evaluate the treatment outcome of six Bredent blueSky™ implants (Bredent GmbH, Senden, Germany) immediately loaded with a fixed full-arch prosthesis (two tilted posterior and four axial frontal and premolar implants). All 10 patients with atrophic edentulous maxillae being treated with a standardized procedure from 09/2009 to 01/2013, who had a follow-up of at least 3 years, were included. Sixty implants were placed to support 10 screwed prostheses. Twenty-one of them were inserted in fresh extraction sockets. Lab-side-prepared provisional fixed prostheses were placed at the day of implantation. Periotest (PT) values and implant stability quotient (ISQ) were measured after implant surgery and after 3 months of healing in all patients. The analyzed implants were in function in mean 64 ± 13 months (range 42 to 84 months). One axial and two tilted implants failed in three patients. The mean PT values decreased, and ISQ increased significantly after the first 3 months at the osseointegrated tilted and axial implants. With an area under the curve of 0.503 and 0.506 in the receiver operating characteristic, the PT values and the ISQ were unspecific parameters and unsuitable as a predictor for the risk of non-osseointegration. Within the limits of this small group (n = 10 patients/60 implants), the failure rate of the analyzed implant system (n = 3 respective 5% implant loss) seems to be comparable with other immediate-loading protocols. The failure rate of tilted implants in the atrophic upper jaw was quite high, but the aimed treatment concept could be achieved in every patient. The rehabilitation of the posterior region in edentulous maxilla remains a challenge.

  14. Digital Workflow for Fixed Implant Rehabilitation of an Extremely Atrophic Edentulous Mandible in Three Appointments.

    Science.gov (United States)

    Papaspyridakos, Panos; Rajput, Neha; Kudara, Yukio; Weber, Hans-Peter

    2017-05-06

    To present a rationale to reduce treatment complexity, number of surgeries, and overall treatment time for patients with extreme mandibular ridge deficiency. A 67-year-old fully edentulous male presented with a chief complaint of poor retention and stability of the mandibular complete denture with consequent discomfort and inability to chew. A novel 3-appointment protocol from guided implant placement to definitive prosthesis delivery was implemented. At the first appointment, a guided surgery protocol with the All-on-4 concept was used in the mandible. Implant placement was followed by immediate loading with a fixed provisional prosthesis providing the patient with immediate function. Final impression, cast verification and articulation, determination of VDO, and interocclusal records were obtained in the same appointment. In the second appointment, the framework try-in was performed and a pick-up impression was taken after a new CR record. The third appointment included the delivery of the final screw-retained, one-piece, full-arch prosthesis opposed by a maxillary complete denture. This expedited protocol allows for implant placement with a surgical template generated from preoperative virtual planning of the implants and the CAD/CAM prosthodontic rehabilitation using a digital workflow. The patient was satisfied with the esthetic and functional outcome and was enrolled into a 6-month recall program. This article describes an expedited protocol illustrating a digital workflow for full arch implant rehabilitation of the extremely atrophic mandible. Flapless implant placement with a surgical template generated from virtual planning was followed by immediate loading with a fixed prosthesis. Digital impression/digitization of the working cast and CAD/CAM technology were used to mill the definitive prosthesis. From guided surgery to the definitive rehabilitation only three appointments were necessary. This digital workflow can enhance patient acceptance and comfort

  15. The Theory of Reich's Fixed Point Theorem for Multivalued Operators

    Directory of Open Access Journals (Sweden)

    Moţ Ghiocel

    2010-01-01

    Full Text Available The purpose of this paper is to present a theory of Reich's fixed point theorem for multivalued operators in terms of fixed points, strict fixed points, multivalued weakly Picard operators, multivalued Picard operators, data dependence of the fixed point set, sequence of multivalued operators and fixed points, Ulam-Hyers stability of a multivalued fixed point equation, well-posedness of the fixed point problem, and the generated fractal operator.

  16. Fixed Conometric Retention with CAD/CAM Conic Coupling Abutments and Prefabricated Syncone Caps: A Case Series.

    Science.gov (United States)

    Bressan, Eriberto; Venezze, Alvise Cenzi; Magaz, Vanessa Ruiz; Lops, Diego; Ghensi, Paolo

    The conometric retention system was proposed and described as a predictable alternative to retain fixed implant-supported complete dentures and, more recently, to retain fixed partial restorations. Currently available studies describe a technique based on the Ankylos (Dentsply) implant system and stock conic coupling abutments. The purpose of this case series study is therefore to demonstrate the possibility of using Atlantis computer-aided design/computer-assisted manufacture technology to produce Conus abutments (Dentsply) and using the fixed conometric retention with other implant brands for which appropriate stock conic coupling abutments are not available.

  17. Hacia un inventario provisional de las tendencias en Bibliotecología y Ciencia de la Información = Towards a provisional inventory of trends in Library and Information Science.

    Directory of Open Access Journals (Sweden)

    Alejandro E. Parada

    2015-12-01

    Full Text Available Este trabajo se presentó como un documento de debate y reflexión en las 1º Jornadas Nacionales de Docentes e Investigadores Universitarios en Ciencia de la Información (DUCI, llevadas a cabo el 3 y 4 de septiembre de 2015 en la Biblioteca Nacional Mariano Moreno. En el texto se señalan, en forma preliminar y provisional, algunas de las perspectivas más importantes de la Bibliotecología y Ciencia de la Información (BCI. En este contexto se citan las siguientes: la crisis de la denominación propia de la identidad, el papel del liderazgo de la profesión en la Web 2.0, el tópico de la cogestión entre los bibliotecarios y los usuarios, las potencialidades de autorrepresentación y deliberación de las bibliotecas, las dimensiones tecnológicas, la construcción de la lingüística profesional, la importancia del análisis de dominio en la web semántica y sus relaciones con el lenguaje, la tendencia a la inclusión, la gestación de los portales de acceso abierto, el paradigma de la diversidad polimórfica, la dimensión teórica y de índole filosófica, entre otras muchas. Finalmente, se señala la trascendencia de la BCI como una disciplina de la pluralidad y diversidad virtual, y como un campo en estado de apertura para que los ciudadanos transformen la información en conocimiento = This work was presented as a document for debate and reflection in the 1º Jornadas Nacionales de Docentes e Investigadores Universitarios en Ciencia de la Información (DUCI held on 3rd and 4th September 2015 at the Biblioteca Nacional Mariano Moreno. The text indicates, in preliminary and provisional way, some of the most important perspectives of Library and Information Science. In this context, the following perspectives are mentioned: The crisis of the identity denomination, the role of leadership of the profession in the Web 2.0, the topic of co-management between librarians and users, the potential of self-representation and deliberation in

  18. Experts’ understanding of partial derivatives using the partial derivative machine

    Directory of Open Access Journals (Sweden)

    David Roundy

    2015-09-01

    Full Text Available [This paper is part of the Focused Collection on Upper Division Physics Courses.] Partial derivatives are used in a variety of different ways within physics. Thermodynamics, in particular, uses partial derivatives in ways that students often find especially confusing. We are at the beginning of a study of the teaching of partial derivatives, with a goal of better aligning the teaching of multivariable calculus with the needs of students in STEM disciplines. In this paper, we report on an initial study of expert understanding of partial derivatives across three disciplines: physics, engineering, and mathematics. We report on the central research question of how disciplinary experts understand partial derivatives, and how their concept images of partial derivatives differ, with a focus on experimentally measured quantities. Using the partial derivative machine (PDM, we probed expert understanding of partial derivatives in an experimental context without a known functional form. In particular, we investigated which representations were cued by the experts’ interactions with the PDM. Whereas the physicists and engineers were quick to use measurements to find a numeric approximation for a derivative, the mathematicians repeatedly returned to speculation as to the functional form; although they were comfortable drawing qualitative conclusions about the system from measurements, they were reluctant to approximate the derivative through measurement. On a theoretical front, we found ways in which existing frameworks for the concept of derivative could be expanded to include numerical approximation.

  19. HEALTH INSURANCE: FIXED CONTRIBUTION AND REIMBURSEMENT MAXIMA

    CERN Document Server

    Human Resources Division

    2001-01-01

    Affected by the salary adjustments on 1 January 2001 and the evolution of the staff members and fellows population, the average reference salary, which is used as an index for fixed contributions and reimbursement maxima, has changed significantly. An adjustment of the amounts of the reimbursement maxima and the fixed contributions is therefore necessary, as from 1 January 2001. Reimbursement maxima The revised reimbursement maxima will appear on the leaflet summarizing the benefits for the year 2001, which will be sent out with the forthcoming issue of the CHIS Bull'. This leaflet will also be available from the divisional secretariats and from the UNIQA office at CERN. Fixed contributions The fixed contributions, applicable to some categories of voluntarily insured persons, are set as follows (amounts in CHF for monthly contributions) : voluntarily insured member of the personnel, with normal health insurance cover : 910.- (was 815.- in 2000) voluntarily insured member of the personnel, with reduced heal...

  20. Anderson Acceleration for Fixed-Point Iterations

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Homer F. [Worcester Polytechnic Institute, MA (United States)

    2015-08-31

    The purpose of this grant was to support research on acceleration methods for fixed-point iterations, with applications to computational frameworks and simulation problems that are of interest to DOE.

  1. Topological fixed point theory of multivalued mappings

    CERN Document Server

    Górniewicz, Lech

    1999-01-01

    This volume presents a broad introduction to the topological fixed point theory of multivalued (set-valued) mappings, treating both classical concepts as well as modern techniques. A variety of up-to-date results is described within a unified framework. Topics covered include the basic theory of set-valued mappings with both convex and nonconvex values, approximation and homological methods in the fixed point theory together with a thorough discussion of various index theories for mappings with a topologically complex structure of values, applications to many fields of mathematics, mathematical economics and related subjects, and the fixed point approach to the theory of ordinary differential inclusions. The work emphasises the topological aspect of the theory, and gives special attention to the Lefschetz and Nielsen fixed point theory for acyclic valued mappings with diverse compactness assumptions via graph approximation and the homological approach. Audience: This work will be of interest to researchers an...

  2. Invariant manifolds near hyperbolic fixed points

    NARCIS (Netherlands)

    Homburg, A.J.

    2006-01-01

    Abstract: In these notes, we discuss obstructions to the existence of local invariant manifolds of some smoothness class, near hyperbolic fixed points of diffeomorphisms. We present an elementary construction for continuously differentiable invariant manifolds that are not necessarily normally

  3. Actinorhizal nitrogen fixing nodules: infection process, molecular ...

    African Journals Online (AJOL)

    Actinorhizal nitrogen fixing nodules: infection process, molecular biology and genomics. Mariana Obertello, Mame Oureye SY, Laurent Laplaze, Carole Santi, Sergio Svistoonoff, Florence Auguy, Didier Bogusz, Claudine Franche ...

  4. Fixed-Point Configurable Hardware Components

    Directory of Open Access Journals (Sweden)

    Rocher Romuald

    2006-01-01

    Full Text Available To reduce the gap between the VLSI technology capability and the designer productivity, design reuse based on IP (intellectual properties is commonly used. In terms of arithmetic accuracy, the generated architecture can generally only be configured through the input and output word lengths. In this paper, a new kind of method to optimize fixed-point arithmetic IP has been proposed. The architecture cost is minimized under accuracy constraints defined by the user. Our approach allows exploring the fixed-point search space and the algorithm-level search space to select the optimized structure and fixed-point specification. To significantly reduce the optimization and design times, analytical models are used for the fixed-point optimization process.

  5. Fractal Structures For Fixed Mems Capacitors

    KAUST Repository

    Elshurafa, Amro M.

    2014-08-28

    An embodiment of a fractal fixed capacitor comprises a capacitor body in a microelectromechanical system (MEMS) structure. The capacitor body has a first plate with a fractal shape separated by a horizontal distance from a second plate with a fractal shape. The first plate and the second plate are within the same plane. Such a fractal fixed capacitor further comprises a substrate above which the capacitor body is positioned.

  6. Random fixed points and random differential inclusions

    Directory of Open Access Journals (Sweden)

    Nikolaos S. Papageorgiou

    1988-01-01

    Full Text Available In this paper, first, we study random best approximations to random sets, using fixed point techniques, obtaining this way stochastic analogues of earlier deterministic results by Browder-Petryshyn, KyFan and Reich. Then we prove two fixed point theorems for random multifunctions with stochastic domain that satisfy certain tangential conditions. Finally we consider a random differential inclusion with upper semicontinuous orientor field and establish the existence of random solutions.

  7. Removable partial denture supported by implants with prefabricated telescopic abutments - a case report.

    Science.gov (United States)

    Kumar, Lalit; Sehgal, Komal

    2014-06-01

    Implants have been designed to rehabilitate edentulous patients with fixed prosthesis or implant supported overdentures. Implant-supported single crowns and fixed partial dentures have become successful treatment alternatives to removable and fixed partial dentures. However, it is common to have clinical situations which make it impossible to use conventional as well as implant supported fixed partial dentures. The implant supported removable partial dentures can be a treatment modality that offers the multitude of benefits of implant-based therapy-biologic, biomechanical, social, and psychological to such patients. The aim of this article is to present a case report describing the fabrication and advantages of removable partial denture supported by teeth and implants for a patient with long edentulous span. The patient was satisfied with his dentures in terms of function and aesthetics. Regular follow-up visits over a period of three years revealed that the periodontal condition of remaining natural dentition and peri-implant conditions were stable. There was no evidence of excessive residual ridge resorption or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs.

  8. [Loading and strength of single- and multi-unit fixed dental prostheses. 1. Retention and resistance].

    Science.gov (United States)

    de Baat, C; Witter, D J; Meijers, C C A J; Vergoossen, E L M; Creugers, N H J

    2014-03-01

    The degree to which single- and multi-unit fixed dental prostheses are able to withstand loading forces is dependent, among other things, on the quality of their retention and resistance. The quality of the retention and resistance of the configuration of an abutment tooth prepared for a metal and metal-ceramic single-unit fixed dental prosthesis is determined by the configuration's convergence angle, the height, the volume, the interocclusal space, the cervical outline design, the additional preparations, the quality of the (build-up) restoration, and the surface roughness. A silicate ceramic single-unit fixed dental prosthesis is attached through adhesion using a composite cement, but the retention and resistance of an oxide ceramic single-unit fixed dental prosthesis is dependent on the abutment tooth configuration. Most types of multi-unit fixed dental prosthesis have the following additional retention and resistance determining factors: the position in the occlusal system, the number of abutment teeth and their mutual configurations, and the length of (cantilever) pontics. A resin-bonded fixed partial denture's retention and resistance are determined by its bonding as well as its enamel surface coverage and its resistance preparations.

  9. Gene therapy for hemophilia B mice with scAAV8-LP1-hFIX.

    Science.gov (United States)

    Lu, Wei; Zhou, Qingzhang; Yang, Hao; Wang, Hao; Gu, Yexing; Shen, Qi; Xue, Jinglun; Dong, Xiaoyan; Chen, Jinzhong

    2016-06-01

    Hemophilia B is a hemorrhagic disease caused by the deficiency of clotting factor IX (FIX). Gene therapy might be the ultimate strategy for the disease. However, two main problems that should be solved in gene therapy for hemophilia B are immunity and safety. Self-complementary adeno-associated virus serotype 8 (scAAV8), a non-human primate AAV featuring low immunogenicity and high transfection efficiency in liver cells, might be a potential vector for hemophilia B gene therapy. A strong liver-specific promoter-1 (LP1) was inserted and mutant human FIX Arg338Ala was introduced into plasmid scAAV8-LP1 to develop an optimized AAV8 vector that expresses human clotting factor FIX (hFIX). The efficiency of scAAV8-LP1-hFIX administered through normal systemic injection or hydrodynamic injection was compared. A high expression was achieved using hydrodynamic injection, and the peak hFIX expression levels in the 5 × 10(11) and 1 × 10(11) virus genome (vg) cohorts were 31.94% and 25.02% of normal level, respectively, at 60 days post-injection. From the perspective of long-term (200 days) expression, both injection methods presented promising results with the concentration value maintained above 4% of normal plasma. The results were further verified by enzyme-linked immunosorbent assay and activated partial thromboplastin time. Our study provides a potential gene therapy method for hemophilia B.

  10. Fixed prosthodontic rehabilitation in a wear patient with Fabry's disease.

    Science.gov (United States)

    Bidra, Avinash S

    2011-10-01

    Fabry's disease is an uncommon X-linked metabolic disorder that leads to abnormal accumulation of glycosphingolipids in the body resulting in a variety of systemic disorders. Few reports have addressed dental findings and management of these patients. This clinical report describes the fixed prosthodontic rehabilitation of an adult male patient with Fabry's disease, who presented with generalized severe wear of the dentition. In addition to numerous systemic morbidities, the patient also presented with intraoral angiokeratomas, telangiactasias, anterior diastemata, bimaxillary prognathism, and other oral findings known to be prominent in these patients. The patient was managed by an interdisciplinary team of dental specialists in close coordination with his nephrologist. The prosthodontic treatment included restorations on all teeth, except mandibular anterior teeth, and the patient was restored with a partial group function scheme of occlusion. At the 3.5-year follow-up appointment, the patient's oral health and integrity of the restorations remained stable. This is the first clinical report describing the prosthodontic management of a patient with Fabry's disease. Unique features related to this patient's fixed prosthodontic treatment include accommodation to complex medical problems, management of maxillary diastemata, and choice of occlusal scheme. © 2011 by The American College of Prosthodontists.

  11. Algorithms over partially ordered sets

    DEFF Research Database (Denmark)

    Baer, Robert M.; Østerby, Ole

    1969-01-01

    We here study some problems concerned with the computational analysis of finite partially ordered sets. We begin (in § 1) by showing that the matrix representation of a binary relationR may always be taken in triangular form ifR is a partial ordering. We consider (in § 2) the chain structure...

  12. [Acrylic resin removable partial dentures

    NARCIS (Netherlands)

    Baat, C. de; Witter, D.J.; Creugers, N.H.J.

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of

  13. Partial Epilepsy with Auditory Features

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2004-07-01

    Full Text Available The clinical characteristics of 53 sporadic (S cases of idiopathic partial epilepsy with auditory features (IPEAF were analyzed and compared to previously reported familial (F cases of autosomal dominant partial epilepsy with auditory features (ADPEAF in a study at the University of Bologna, Italy.

  14. A Unification of G-Metric, Partial Metric, and b-Metric Spaces

    Directory of Open Access Journals (Sweden)

    Nawab Hussain

    2014-01-01

    Full Text Available Using the concepts of G-metric, partial metric, and b-metric spaces, we define a new concept of generalized partial b-metric space. Topological and structural properties of the new space are investigated and certain fixed point theorems for contractive mappings in such spaces are obtained. Some examples are provided here to illustrate the usability of the obtained results.

  15. A DISCUSSION ON SOME RECENT COUPLED FIXED POINT RESULTS VIA NEW GENERALIZED NONLINEAR CONTRACTIVE CONDITIONS

    Directory of Open Access Journals (Sweden)

    MANISH JAIN

    2017-06-01

    Full Text Available Recently, Samet et al. [34], by using the equivalence of the three basic metrics showed that certain coupled fixed point results can be obtained immediately from the well-known fixed point theorems. In the setting of partially ordered metric spaces, we establish a generalization of the recent coupled fixed / coincidence point results under new nonlinear contractive conditions. The signicant feature of the presented work is that, our obtained results are not the immediate consequence of the already existing results in the literature. Presented work generalizes some of the results of Bhaskar and Lakshmikantham [6], Berinde [7], Choudhury et al. [10], Harjani et al. [17], Jain et al. [21] , Karapinar et al. [22], Luong and Thuan [25], and Rasouli and Bahrampour [30].

  16. Assessment of Various Factors for Feasibility of Fixed Cantilever Bridge: A Review Study

    OpenAIRE

    Ashu Sharma; G. R. Rahul; Soorya T. Poduval; Karunakar Shetty

    2012-01-01

    Cantilever fixed partial dentures are defined as having one or more abutments at one end of the prosthesis while the other end is unsupported. Much controversy without documentary evidence has surrounded this prosthesis. Despite negative arguments, the cantilever prosthesis has been used extensively by the clinicians. If used nonjudiciously without following proper guidelines these might lead to some complications. Although complications may be an indication that clinical failure has occurred...

  17. Positive Solutions for Fractional Differential Equations from Real Estate Asset Securitization via New Fixed Point Theorem

    Directory of Open Access Journals (Sweden)

    Hao Tao

    2012-01-01

    analysis of real estate asset securitization by using the generalized fixed point theorem for weakly contractive mappings in partially ordered sets. Based on the analysis for the existence and uniqueness of the solution and scientific numerical calculation of the solution, in further study, some optimization schemes for traditional risk control process will be obtained, and then the main results of this paper can be applied to the forefront of research of real estate asset securitization.

  18. Cast Partial Denture versus Acrylic Partial Denture for Replacement of Missing Teeth in Partially Edentulous Patients

    Directory of Open Access Journals (Sweden)

    Pramita Suwal

    2017-03-01

    Full Text Available Aim: To compare the effects of cast partial denture with conventional all acrylic denture in respect to retention, stability, masticatory efficiency, comfort and periodontal health of abutments. Methods: 50 adult partially edentulous patient seeking for replacement of missing teeth having Kennedy class I and II arches with or without modification areas were selected for the study. Group-A was treated with cast partial denture and Group-B with acrylic partial denture. Data collected during follow-up visit of 3 months, 6 months, and 1 year by evaluating retention, stability, masticatory efficiency, comfort, periodontal health of abutment. Results: Chi-square test was applied to find out differences between the groups at 95% confidence interval where p = 0.05. One year comparison shows that cast partial denture maintained retention and stability better than acrylic partial denture (p< 0.05. The masticatory efficiency was significantly compromising from 3rd month to 1 year in all acrylic partial denture groups (p< 0.05. The comfort of patient with cast partial denture was maintained better during the observation period (p< 0.05. Periodontal health of abutment was gradually deteriorated in all acrylic denture group (p

  19. Fixed Dosing of Monoclonal Antibodies in Oncology.

    Science.gov (United States)

    Hendrikx, Jeroen J M A; Haanen, John B A G; Voest, Emile E; Schellens, Jan H M; Huitema, Alwin D R; Beijnen, Jos H

    2017-10-01

    Most monoclonal antibodies in oncology are administered in body-size-based dosing schedules. This is believed to correct for variability in both drug distribution and elimination between patients. However, monoclonal antibodies typically distribute to the blood plasma and extracellular fluids only, which increase less than proportionally with the increase in body weight. Elimination takes place via proteolytic catabolism, a nonspecific immunoglobulin G elimination pathway, and intracellular degradation after binding to the target. The latter is the primary route of elimination and is related to target expression levels rather than body size. Taken together, the minor effects of body size on distribution and elimination of monoclonal antibodies and their usually wide therapeutic window do not support body-size-based dosing. We evaluated effects of body weight on volume of distribution and clearance of monoclonal antibodies in oncology and show that a fixed dose for most of these drugs is justified based on pharmacokinetics. A survey of the savings after fixed dosing of monoclonal antibodies at our hospital showed that fixed dosing can reduce costs of health care, especially when pooling of preparations is not possible (which is often the case in smaller hospitals). In conclusion, based on pharmacokinetic parameters of monoclonal antibodies, there is a rationale for fixed dosing of these drugs in oncology. Therefore, we believe that fixed dosing is justified and can improve efficiency of the compounding. Moreover, drug spillage can be reduced and medication errors may become less likely. The currently available knowledge of elimination of monoclonal antibodies combined with the publicly available data from clinical trials and extensive population pharmacokinetic (PopPK) modeling justifies fixed dosing. Interpatient variation in exposure is comparable after body weight and fixed dosing and most monoclonal antibodies show relatively flat dose-response relationships

  20. The computation of fixed points and applications

    CERN Document Server

    Todd, Michael J

    1976-01-01

    Fixed-point algorithms have diverse applications in economics, optimization, game theory and the numerical solution of boundary-value problems. Since Scarf's pioneering work [56,57] on obtaining approximate fixed points of continuous mappings, a great deal of research has been done in extending the applicability and improving the efficiency of fixed-point methods. Much of this work is available only in research papers, although Scarf's book [58] gives a remarkably clear exposition of the power of fixed-point methods. However, the algorithms described by Scarf have been super~eded by the more sophisticated restart and homotopy techniques of Merrill [~8,~9] and Eaves and Saigal [1~,16]. To understand the more efficient algorithms one must become familiar with the notions of triangulation and simplicial approxi- tion, whereas Scarf stresses the concept of primitive set. These notes are intended to introduce to a wider audience the most recent fixed-point methods and their applications. Our approach is therefore ...