WorldWideScience

Sample records for provide accurate timely

  1. Measuring physical inactivity: do current measures provide an accurate view of "sedentary" video game time?

    Science.gov (United States)

    Fullerton, Simon; Taylor, Anne W; Dal Grande, Eleonora; Berry, Narelle

    2014-01-01

    Measures of screen time are often used to assess sedentary behaviour. Participation in activity-based video games (exergames) can contribute to estimates of screen time, as current practices of measuring it do not consider the growing evidence that playing exergames can provide light to moderate levels of physical activity. This study aimed to determine what proportion of time spent playing video games was actually spent playing exergames. Data were collected via a cross-sectional telephone survey in South Australia. Participants aged 18 years and above (n = 2026) were asked about their video game habits, as well as demographic and socioeconomic factors. In cases where children were in the household, the video game habits of a randomly selected child were also questioned. Overall, 31.3% of adults and 79.9% of children spend at least some time playing video games. Of these, 24.1% of adults and 42.1% of children play exergames, with these types of games accounting for a third of all time that adults spend playing video games and nearly 20% of children's video game time. A substantial proportion of time that would usually be classified as "sedentary" may actually be spent participating in light to moderate physical activity.

  2. Do wavelet filters provide more accurate estimates of reverberation times at low frequencies

    DEFF Research Database (Denmark)

    Sobreira Seoane, Manuel A.; Pérez Cabo, David; Agerkvist, Finn T.

    2016-01-01

    It has been amply demonstrated in the literature that it is not possible to measure acoustic decays without significant errors for low BT values (narrow filters and or low reverberation times). Recently, it has been shown how the main source of distortion in the time envelope of the acoustic deca...

  3. Measuring Physical Inactivity: Do Current Measures Provide an Accurate View of “Sedentary” Video Game Time?

    Directory of Open Access Journals (Sweden)

    Simon Fullerton

    2014-01-01

    Full Text Available Background. Measures of screen time are often used to assess sedentary behaviour. Participation in activity-based video games (exergames can contribute to estimates of screen time, as current practices of measuring it do not consider the growing evidence that playing exergames can provide light to moderate levels of physical activity. This study aimed to determine what proportion of time spent playing video games was actually spent playing exergames. Methods. Data were collected via a cross-sectional telephone survey in South Australia. Participants aged 18 years and above (n=2026 were asked about their video game habits, as well as demographic and socioeconomic factors. In cases where children were in the household, the video game habits of a randomly selected child were also questioned. Results. Overall, 31.3% of adults and 79.9% of children spend at least some time playing video games. Of these, 24.1% of adults and 42.1% of children play exergames, with these types of games accounting for a third of all time that adults spend playing video games and nearly 20% of children’s video game time. Conclusions. A substantial proportion of time that would usually be classified as “sedentary” may actually be spent participating in light to moderate physical activity.

  4. Integrating GPS, GYRO, vehicle speed sensor, and digital map to provide accurate and real-time position in an intelligent navigation system

    Science.gov (United States)

    Li, Qingquan; Fang, Zhixiang; Li, Hanwu; Xiao, Hui

    2005-10-01

    The global positioning system (GPS) has become the most extensively used positioning and navigation tool in the world. Applications of GPS abound in surveying, mapping, transportation, agriculture, military planning, GIS, and the geosciences. However, the positional and elevation accuracy of any given GPS location is prone to error, due to a number of factors. The applications of Global Positioning System (GPS) positioning is more and more popular, especially the intelligent navigation system which relies on GPS and Dead Reckoning technology is developing quickly for future huge market in China. In this paper a practical combined positioning model of GPS/DR/MM is put forward, which integrates GPS, Gyro, Vehicle Speed Sensor (VSS) and digital navigation maps to provide accurate and real-time position for intelligent navigation system. This model is designed for automotive navigation system making use of Kalman filter to improve position and map matching veracity by means of filtering raw GPS and DR signals, and then map-matching technology is used to provide map coordinates for map displaying. In practical examples, for illustrating the validity of the model, several experiments and their results of integrated GPS/DR positioning in intelligent navigation system will be shown for the conclusion that Kalman Filter based GPS/DR integrating position approach is necessary, feasible and efficient for intelligent navigation application. Certainly, this combined positioning model, similar to other model, can not resolve all situation issues. Finally, some suggestions are given for further improving integrated GPS/DR/MM application.

  5. 3D Vision Provides Shorter Operative Time and More Accurate Intraoperative Surgical Performance in Laparoscopic Hiatal Hernia Repair Compared With 2D Vision.

    Science.gov (United States)

    Leon, Piera; Rivellini, Roberta; Giudici, Fabiola; Sciuto, Antonio; Pirozzi, Felice; Corcione, Francesco

    2017-04-01

    The aim of this study is to evaluate if 3-dimensional high-definition (3D) vision in laparoscopy can prompt advantages over conventional 2D high-definition vision in hiatal hernia (HH) repair. Between September 2012 and September 2015, we randomized 36 patients affected by symptomatic HH to undergo surgery; 17 patients underwent 2D laparoscopic HH repair, whereas 19 patients underwent the same operation in 3D vision. No conversion to open surgery occurred. Overall operative time was significantly reduced in the 3D laparoscopic group compared with the 2D one (69.9 vs 90.1 minutes, P = .006). Operative time to perform laparoscopic crura closure did not differ significantly between the 2 groups. We observed a tendency to a faster crura closure in the 3D group in the subgroup of patients with mesh positioning (7.5 vs 8.9 minutes, P = .09). Nissen fundoplication was faster in the 3D group without mesh positioning ( P = .07). 3D vision in laparoscopic HH repair helps surgeon's visualization and seems to lead to operative time reduction. Advantages can result from the enhanced spatial perception of narrow spaces. Less operative time and more accurate surgery translate to benefit for patients and cost savings, compensating the high costs of the 3D technology. However, more data from larger series are needed to firmly assess the advantages of 3D over 2D vision in laparoscopic HH repair.

  6. Low resolution scans can provide a sufficiently accurate, cost- and time-effective alternative to high resolution scans for 3D shape analyses

    Directory of Open Access Journals (Sweden)

    Ariel E. Marcy

    2018-06-01

    Full Text Available Background Advances in 3D shape capture technology have made powerful shape analyses, such as geometric morphometrics, more feasible. While the highly accurate micro-computed tomography (µCT scanners have been the “gold standard,” recent improvements in 3D surface scanners may make this technology a faster, portable, and cost-effective alternative. Several studies have already compared the two devices but all use relatively large specimens such as human crania. Here we perform shape analyses on Australia’s smallest rodent to test whether a 3D scanner produces similar results to a µCT scanner. Methods We captured 19 delicate mouse (Pseudomys delicatulus crania with a µCT scanner and a 3D scanner for geometric morphometrics. We ran multiple Procrustes ANOVAs to test how variation due to scan device compared to other sources such as biologically relevant variation and operator error. We quantified operator error as levels of variation and repeatability. Further, we tested if the two devices performed differently at classifying individuals based on sexual dimorphism. Finally, we inspected scatterplots of principal component analysis (PCA scores for non-random patterns. Results In all Procrustes ANOVAs, regardless of factors included, differences between individuals contributed the most to total variation. The PCA plots reflect this in how the individuals are dispersed. Including only the symmetric component of shape increased the biological signal relative to variation due to device and due to error. 3D scans showed a higher level of operator error as evidenced by a greater spread of their replicates on the PCA, a higher level of multivariate variation, and a lower repeatability score. However, the 3D scan and µCT scan datasets performed identically in classifying individuals based on intra-specific patterns of sexual dimorphism. Discussion Compared to µCT scans, we find that even low resolution 3D scans of very small specimens are

  7. Accurate estimation of indoor travel times

    DEFF Research Database (Denmark)

    Prentow, Thor Siiger; Blunck, Henrik; Stisen, Allan

    2014-01-01

    The ability to accurately estimate indoor travel times is crucial for enabling improvements within application areas such as indoor navigation, logistics for mobile workers, and facility management. In this paper, we study the challenges inherent in indoor travel time estimation, and we propose...... the InTraTime method for accurately estimating indoor travel times via mining of historical and real-time indoor position traces. The method learns during operation both travel routes, travel times and their respective likelihood---both for routes traveled as well as for sub-routes thereof. InTraTime...... allows to specify temporal and other query parameters, such as time-of-day, day-of-week or the identity of the traveling individual. As input the method is designed to take generic position traces and is thus interoperable with a variety of indoor positioning systems. The method's advantages include...

  8. Implicit time accurate simulation of unsteady flow

    Science.gov (United States)

    van Buuren, René; Kuerten, Hans; Geurts, Bernard J.

    2001-03-01

    Implicit time integration was studied in the context of unsteady shock-boundary layer interaction flow. With an explicit second-order Runge-Kutta scheme, a reference solution to compare with the implicit second-order Crank-Nicolson scheme was determined. The time step in the explicit scheme is restricted by both temporal accuracy as well as stability requirements, whereas in the A-stable implicit scheme, the time step has to obey temporal resolution requirements and numerical convergence conditions. The non-linear discrete equations for each time step are solved iteratively by adding a pseudo-time derivative. The quasi-Newton approach is adopted and the linear systems that arise are approximately solved with a symmetric block Gauss-Seidel solver. As a guiding principle for properly setting numerical time integration parameters that yield an efficient time accurate capturing of the solution, the global error caused by the temporal integration is compared with the error resulting from the spatial discretization. Focus is on the sensitivity of properties of the solution in relation to the time step. Numerical simulations show that the time step needed for acceptable accuracy can be considerably larger than the explicit stability time step; typical ratios range from 20 to 80. At large time steps, convergence problems that are closely related to a highly complex structure of the basins of attraction of the iterative method may occur. Copyright

  9. Fishing site mapping using local knowledge provides accurate and ...

    African Journals Online (AJOL)

    Accurate fishing ground maps are necessary for fisheries monitoring. In Velondriake locally managed marine area (LMMA) we observed that the nomenclature of shared fishing sites (FS) is villages dependent. Additionally, the level of illiteracy makes data collection more complicated, leading to data collectors improvising ...

  10. Do detour tasks provide accurate assays of inhibitory control?

    Science.gov (United States)

    Whiteside, Mark A.; Laker, Philippa R.; Beardsworth, Christine E.

    2018-01-01

    Transparent Cylinder and Barrier tasks are used to purportedly assess inhibitory control in a variety of animals. However, we suspect that performances on these detour tasks are influenced by non-cognitive traits, which may result in inaccurate assays of inhibitory control. We therefore reared pheasants under standardized conditions and presented each bird with two sets of similar tasks commonly used to measure inhibitory control. We recorded the number of times subjects incorrectly attempted to access a reward through transparent barriers, and their latencies to solve each task. Such measures are commonly used to infer the differential expression of inhibitory control. We found little evidence that their performances were consistent across the two different Putative Inhibitory Control Tasks (PICTs). Improvements in performance across trials showed that pheasants learned the affordances of each specific task. Critically, prior experience of transparent tasks, either Barrier or Cylinder, also improved subsequent inhibitory control performance on a novel task, suggesting that they also learned the general properties of transparent obstacles. Individual measures of persistence, assayed in a third task, were positively related to their frequency of incorrect attempts to solve the transparent inhibitory control tasks. Neophobia, Sex and Body Condition had no influence on individual performance. Contrary to previous studies of primates, pheasants with poor performance on PICTs had a wider dietary breadth assayed using a free-choice task. Our results demonstrate that in systems or taxa where prior experience and differences in development cannot be accounted for, individual differences in performance on commonly used detour-dependent PICTS may reveal more about an individual's prior experience of transparent objects, or their motivation to acquire food, than providing a reliable measure of their inhibitory control. PMID:29593115

  11. Multipurpose discriminator with accurate time coupling

    International Nuclear Information System (INIS)

    Baldin, B.Yu.; Krumshtejn, Z.V.; Ronzhin, A.I.

    1977-01-01

    The principle diagram of a multipurpose discriminator is described, designed on the basis of a wide-band differential amplifier. The discriminator has three independent channels: the timing channel, the lower level discriminator and the control channel. The timing channel and the lower level discriminator are connected to a coincidence circuit. Three methods of timing are used: a single threshold, a double threshold with timing on the pulse front, and a constant fraction timing. The lower level discriminator is a wide-band amplifier with an adjustable threshold. The investigation of compensation characteristics of the discriminator has shown that the time shift of the discriminator output in the constant fraction timing regime does not exceed +-75 ns for the input signal range of 1:85. The time resolution was found to be 20 ns in the 20% energy range near the photo-peak maximum of 60 Co γ source

  12. Accurate and efficient calculation of response times for groundwater flow

    Science.gov (United States)

    Carr, Elliot J.; Simpson, Matthew J.

    2018-03-01

    We study measures of the amount of time required for transient flow in heterogeneous porous media to effectively reach steady state, also known as the response time. Here, we develop a new approach that extends the concept of mean action time. Previous applications of the theory of mean action time to estimate the response time use the first two central moments of the probability density function associated with the transition from the initial condition, at t = 0, to the steady state condition that arises in the long time limit, as t → ∞ . This previous approach leads to a computationally convenient estimation of the response time, but the accuracy can be poor. Here, we outline a powerful extension using the first k raw moments, showing how to produce an extremely accurate estimate by making use of asymptotic properties of the cumulative distribution function. Results are validated using an existing laboratory-scale data set describing flow in a homogeneous porous medium. In addition, we demonstrate how the results also apply to flow in heterogeneous porous media. Overall, the new method is: (i) extremely accurate; and (ii) computationally inexpensive. In fact, the computational cost of the new method is orders of magnitude less than the computational effort required to study the response time by solving the transient flow equation. Furthermore, the approach provides a rigorous mathematical connection with the heuristic argument that the response time for flow in a homogeneous porous medium is proportional to L2 / D , where L is a relevant length scale, and D is the aquifer diffusivity. Here, we extend such heuristic arguments by providing a clear mathematical definition of the proportionality constant.

  13. High accurate time system of the Low Latitude Meridian Circle.

    Science.gov (United States)

    Yang, Jing; Wang, Feng; Li, Zhiming

    In order to obtain the high accurate time signal for the Low Latitude Meridian Circle (LLMC), a new GPS accurate time system is developed which include GPS, 1 MC frequency source and self-made clock system. The second signal of GPS is synchronously used in the clock system and information can be collected by a computer automatically. The difficulty of the cancellation of the time keeper can be overcomed by using this system.

  14. Time scale controversy: Accurate orbital calibration of the early Paleogene

    Science.gov (United States)

    Roehl, U.; Westerhold, T.; Laskar, J.

    2012-12-01

    Timing is crucial to understanding the causes and consequences of events in Earth history. The calibration of geological time relies heavily on the accuracy of radioisotopic and astronomical dating. Uncertainties in the computations of Earth's orbital parameters and in radioisotopic dating have hampered the construction of a reliable astronomically calibrated time scale beyond 40 Ma. Attempts to construct a robust astronomically tuned time scale for the early Paleogene by integrating radioisotopic and astronomical dating are only partially consistent. Here, using the new La2010 and La2011 orbital solutions, we present the first accurate astronomically calibrated time scale for the early Paleogene (47-65 Ma) uniquely based on astronomical tuning and thus independent of the radioisotopic determination of the Fish Canyon standard. Comparison with geological data confirms the stability of the new La2011 solution back to 54 Ma. Subsequent anchoring of floating chronologies to the La2011 solution using the very long eccentricity nodes provides an absolute age of 55.530 ± 0.05 Ma for the onset of the Paleocene/Eocene Thermal Maximum (PETM), 54.850 ± 0.05 Ma for the early Eocene ash -17, and 65.250 ± 0.06 Ma for the K/Pg boundary. The new astrochronology presented here indicates that the intercalibration and synchronization of U/Pb and 40Ar/39Ar radioisotopic geochronology is much more challenging than previously thought.

  15. Current generation time-of-flight 18F-FDG PET/CT provides higher SUVs for normal adrenal glands, while maintaining an accurate characterization of benign and malignant glands

    NARCIS (Netherlands)

    Koopman, Daniëlle; Koopman, Daniëlle; van Dalen, Jorn A.; Stigt, Jos A.; Slump, Cornelis H.; Knollema, Siert; Jager, Pieter L.

    ObjectiveModern PET/CT scanners have significantly improved detectors and fast time-of-flight (TOF) performance and this may improve clinical performance. The aim of this study was to analyze the impact of a current generation TOF PET/CT scanner on standardized uptake values (SUV), lesion-background

  16. Multigrid time-accurate integration of Navier-Stokes equations

    Science.gov (United States)

    Arnone, Andrea; Liou, Meng-Sing; Povinelli, Louis A.

    1993-01-01

    Efficient acceleration techniques typical of explicit steady-state solvers are extended to time-accurate calculations. Stability restrictions are greatly reduced by means of a fully implicit time discretization. A four-stage Runge-Kutta scheme with local time stepping, residual smoothing, and multigridding is used instead of traditional time-expensive factorizations. Some applications to natural and forced unsteady viscous flows show the capability of the procedure.

  17. Towards an accurate real-time locator of infrasonic sources

    Science.gov (United States)

    Pinsky, V.; Blom, P.; Polozov, A.; Marcillo, O.; Arrowsmith, S.; Hofstetter, A.

    2017-11-01

    Infrasonic signals propagate from an atmospheric source via media with stochastic and fast space-varying conditions. Hence, their travel time, the amplitude at sensor recordings and even manifestation in the so-called "shadow zones" are random. Therefore, the traditional least-squares technique for locating infrasonic sources is often not effective, and the problem for the best solution must be formulated in probabilistic terms. Recently, a series of papers has been published about Bayesian Infrasonic Source Localization (BISL) method based on the computation of the posterior probability density function (PPDF) of the source location, as a convolution of a priori probability distribution function (APDF) of the propagation model parameters with likelihood function (LF) of observations. The present study is devoted to the further development of BISL for higher accuracy and stability of the source location results and decreasing of computational load. We critically analyse previous algorithms and propose several new ones. First of all, we describe the general PPDF formulation and demonstrate that this relatively slow algorithm might be among the most accurate algorithms, provided the adequate APDF and LF are used. Then, we suggest using summation instead of integration in a general PPDF calculation for increased robustness, but this leads us to the 3D space-time optimization problem. Two different forms of APDF approximation are considered and applied for the PPDF calculation in our study. One of them is previously suggested, but not yet properly used is the so-called "celerity-range histograms" (CRHs). Another is the outcome from previous findings of linear mean travel time for the four first infrasonic phases in the overlapping consecutive distance ranges. This stochastic model is extended here to the regional distance of 1000 km, and the APDF introduced is the probabilistic form of the junction between this travel time model and range-dependent probability

  18. Accurate Sample Time Reconstruction of Inertial FIFO Data

    Directory of Open Access Journals (Sweden)

    Sebastian Stieber

    2017-12-01

    Full Text Available In the context of modern cyber-physical systems, the accuracy of underlying sensor data plays an increasingly important role in sensor data fusion and feature extraction. The raw events of multiple sensors have to be aligned in time to enable high quality sensor fusion results. However, the growing number of simultaneously connected sensor devices make the energy saving data acquisition and processing more and more difficult. Hence, most of the modern sensors offer a first-in-first-out (FIFO interface to store multiple data samples and to relax timing constraints, when handling multiple sensor devices. However, using the FIFO interface increases the negative influence of individual clock drifts—introduced by fabrication inaccuracies, temperature changes and wear-out effects—onto the sampling data reconstruction. Furthermore, additional timing offset errors due to communication and software latencies increases with a growing number of sensor devices. In this article, we present an approach for an accurate sample time reconstruction independent of the actual clock drift with the help of an internal sensor timer. Such timers are already available in modern sensors, manufactured in micro-electromechanical systems (MEMS technology. The presented approach focuses on calculating accurate time stamps using the sensor FIFO interface in a forward-only processing manner as a robust and energy saving solution. The proposed algorithm is able to lower the overall standard deviation of reconstructed sampling periods below 40 μ s, while run-time savings of up to 42% are achieved, compared to single sample acquisition.

  19. A New Multiscale Technique for Time-Accurate Geophysics Simulations

    Science.gov (United States)

    Omelchenko, Y. A.; Karimabadi, H.

    2006-12-01

    Large-scale geophysics systems are frequently described by multiscale reactive flow models (e.g., wildfire and climate models, multiphase flows in porous rocks, etc.). Accurate and robust simulations of such systems by traditional time-stepping techniques face a formidable computational challenge. Explicit time integration suffers from global (CFL and accuracy) timestep restrictions due to inhomogeneous convective and diffusion processes, as well as closely coupled physical and chemical reactions. Application of adaptive mesh refinement (AMR) to such systems may not be always sufficient since its success critically depends on a careful choice of domain refinement strategy. On the other hand, implicit and timestep-splitting integrations may result in a considerable loss of accuracy when fast transients in the solution become important. To address this issue, we developed an alternative explicit approach to time-accurate integration of such systems: Discrete-Event Simulation (DES). DES enables asynchronous computation by automatically adjusting the CPU resources in accordance with local timescales. This is done by encapsulating flux- conservative updates of numerical variables in the form of events, whose execution and synchronization is explicitly controlled by imposing accuracy and causality constraints. As a result, at each time step DES self- adaptively updates only a fraction of the global system state, which eliminates unnecessary computation of inactive elements. DES can be naturally combined with various mesh generation techniques. The event-driven paradigm results in robust and fast simulation codes, which can be efficiently parallelized via a new preemptive event processing (PEP) technique. We discuss applications of this novel technology to time-dependent diffusion-advection-reaction and CFD models representative of various geophysics applications.

  20. Accurate light-time correction due to a gravitating mass

    Energy Technology Data Exchange (ETDEWEB)

    Ashby, Neil [Department of Physics, University of Colorado, Boulder, CO (United States); Bertotti, Bruno, E-mail: ashby@boulder.nist.go [Dipartimento di Fisica Nucleare e Teorica, Universita di Pavia (Italy)

    2010-07-21

    This technical paper of mathematical physics arose as an aftermath of the 2002 Cassini experiment (Bertotti et al 2003 Nature 425 374-6), in which the PPN parameter {gamma} was measured with an accuracy {sigma}{sub {gamma}} = 2.3 x 10{sup -5} and found consistent with the prediction {gamma} = 1 of general relativity. The Orbit Determination Program (ODP) of NASA's Jet Propulsion Laboratory, which was used in the data analysis, is based on an expression (8) for the gravitational delay {Delta}t that differs from the standard formula (2); this difference is of second order in powers of m-the gravitational radius of the Sun-but in Cassini's case it was much larger than the expected order of magnitude m{sup 2}/b, where b is the distance of the closest approach of the ray. Since the ODP does not take into account any other second-order terms, it is necessary, also in view of future more accurate experiments, to revisit the whole problem, to systematically evaluate higher order corrections and to determine which terms, and why, are larger than the expected value. We note that light propagation in a static spacetime is equivalent to a problem in ordinary geometrical optics; Fermat's action functional at its minimum is just the light-time between the two end points A and B. A new and powerful formulation is thus obtained. This method is closely connected with the much more general approach of Le Poncin-Lafitte et al (2004 Class. Quantum Grav. 21 4463-83), which is based on Synge's world function. Asymptotic power series are necessary to provide a safe and automatic way of selecting which terms to keep at each order. Higher order approximations to the required quantities, in particular the delay and the deflection, are easily obtained. We also show that in a close superior conjunction, when b is much smaller than the distances of A and B from the Sun, say of order R, the second-order correction has an enhanced part of order m{sup 2}R/b{sup 2}, which

  1. Technical Note: Using experimentally determined proton spot scanning timing parameters to accurately model beam delivery time.

    Science.gov (United States)

    Shen, Jiajian; Tryggestad, Erik; Younkin, James E; Keole, Sameer R; Furutani, Keith M; Kang, Yixiu; Herman, Michael G; Bues, Martin

    2017-10-01

    To accurately model the beam delivery time (BDT) for a synchrotron-based proton spot scanning system using experimentally determined beam parameters. A model to simulate the proton spot delivery sequences was constructed, and BDT was calculated by summing times for layer switch, spot switch, and spot delivery. Test plans were designed to isolate and quantify the relevant beam parameters in the operation cycle of the proton beam therapy delivery system. These parameters included the layer switch time, magnet preparation and verification time, average beam scanning speeds in x- and y-directions, proton spill rate, and maximum charge and maximum extraction time for each spill. The experimentally determined parameters, as well as the nominal values initially provided by the vendor, served as inputs to the model to predict BDTs for 602 clinical proton beam deliveries. The calculated BDTs (T BDT ) were compared with the BDTs recorded in the treatment delivery log files (T Log ): ∆t = T Log -T BDT . The experimentally determined average layer switch time for all 97 energies was 1.91 s (ranging from 1.9 to 2.0 s for beam energies from 71.3 to 228.8 MeV), average magnet preparation and verification time was 1.93 ms, the average scanning speeds were 5.9 m/s in x-direction and 19.3 m/s in y-direction, the proton spill rate was 8.7 MU/s, and the maximum proton charge available for one acceleration is 2.0 ± 0.4 nC. Some of the measured parameters differed from the nominal values provided by the vendor. The calculated BDTs using experimentally determined parameters matched the recorded BDTs of 602 beam deliveries (∆t = -0.49 ± 1.44 s), which were significantly more accurate than BDTs calculated using nominal timing parameters (∆t = -7.48 ± 6.97 s). An accurate model for BDT prediction was achieved by using the experimentally determined proton beam therapy delivery parameters, which may be useful in modeling the interplay effect and patient throughput. The model may

  2. Reducing dose calculation time for accurate iterative IMRT planning

    International Nuclear Information System (INIS)

    Siebers, Jeffrey V.; Lauterbach, Marc; Tong, Shidong; Wu Qiuwen; Mohan, Radhe

    2002-01-01

    A time-consuming component of IMRT optimization is the dose computation required in each iteration for the evaluation of the objective function. Accurate superposition/convolution (SC) and Monte Carlo (MC) dose calculations are currently considered too time-consuming for iterative IMRT dose calculation. Thus, fast, but less accurate algorithms such as pencil beam (PB) algorithms are typically used in most current IMRT systems. This paper describes two hybrid methods that utilize the speed of fast PB algorithms yet achieve the accuracy of optimizing based upon SC algorithms via the application of dose correction matrices. In one method, the ratio method, an infrequently computed voxel-by-voxel dose ratio matrix (R=D SC /D PB ) is applied for each beam to the dose distributions calculated with the PB method during the optimization. That is, D PB xR is used for the dose calculation during the optimization. The optimization proceeds until both the IMRT beam intensities and the dose correction ratio matrix converge. In the second method, the correction method, a periodically computed voxel-by-voxel correction matrix for each beam, defined to be the difference between the SC and PB dose computations, is used to correct PB dose distributions. To validate the methods, IMRT treatment plans developed with the hybrid methods are compared with those obtained when the SC algorithm is used for all optimization iterations and with those obtained when PB-based optimization is followed by SC-based optimization. In the 12 patient cases studied, no clinically significant differences exist in the final treatment plans developed with each of the dose computation methodologies. However, the number of time-consuming SC iterations is reduced from 6-32 for pure SC optimization to four or less for the ratio matrix method and five or less for the correction method. Because the PB algorithm is faster at computing dose, this reduces the inverse planning optimization time for our implementation

  3. Approaches for the accurate definition of geological time boundaries

    Science.gov (United States)

    Schaltegger, Urs; Baresel, Björn; Ovtcharova, Maria; Goudemand, Nicolas; Bucher, Hugo

    2015-04-01

    Which strategies lead to the most precise and accurate date of a given geological boundary? Geological units are usually defined by the occurrence of characteristic taxa and hence boundaries between these geological units correspond to dramatic faunal and/or floral turnovers and they are primarily defined using first or last occurrences of index species, or ideally by the separation interval between two consecutive, characteristic associations of fossil taxa. These boundaries need to be defined in a way that enables their worldwide recognition and correlation across different stratigraphic successions, using tools as different as bio-, magneto-, and chemo-stratigraphy, and astrochronology. Sedimentary sequences can be dated in numerical terms by applying high-precision chemical-abrasion, isotope-dilution, thermal-ionization mass spectrometry (CA-ID-TIMS) U-Pb age determination to zircon (ZrSiO4) in intercalated volcanic ashes. But, though volcanic activity is common in geological history, ashes are not necessarily close to the boundary we would like to date precisely and accurately. In addition, U-Pb zircon data sets may be very complex and difficult to interpret in terms of the age of ash deposition. To overcome these difficulties we use a multi-proxy approach we applied to the precise and accurate dating of the Permo-Triassic and Early-Middle Triassic boundaries in South China. a) Dense sampling of ashes across the critical time interval and a sufficiently large number of analysed zircons per ash sample can guarantee the recognition of all system complexities. Geochronological datasets from U-Pb dating of volcanic zircon may indeed combine effects of i) post-crystallization Pb loss from percolation of hydrothermal fluids (even using chemical abrasion), with ii) age dispersion from prolonged residence of earlier crystallized zircon in the magmatic system. As a result, U-Pb dates of individual zircons are both apparently younger and older than the depositional age

  4. Novel serologic biomarkers provide accurate estimates of recent Plasmodium falciparum exposure for individuals and communities.

    Science.gov (United States)

    Helb, Danica A; Tetteh, Kevin K A; Felgner, Philip L; Skinner, Jeff; Hubbard, Alan; Arinaitwe, Emmanuel; Mayanja-Kizza, Harriet; Ssewanyana, Isaac; Kamya, Moses R; Beeson, James G; Tappero, Jordan; Smith, David L; Crompton, Peter D; Rosenthal, Philip J; Dorsey, Grant; Drakeley, Christopher J; Greenhouse, Bryan

    2015-08-11

    Tools to reliably measure Plasmodium falciparum (Pf) exposure in individuals and communities are needed to guide and evaluate malaria control interventions. Serologic assays can potentially produce precise exposure estimates at low cost; however, current approaches based on responses to a few characterized antigens are not designed to estimate exposure in individuals. Pf-specific antibody responses differ by antigen, suggesting that selection of antigens with defined kinetic profiles will improve estimates of Pf exposure. To identify novel serologic biomarkers of malaria exposure, we evaluated responses to 856 Pf antigens by protein microarray in 186 Ugandan children, for whom detailed Pf exposure data were available. Using data-adaptive statistical methods, we identified combinations of antibody responses that maximized information on an individual's recent exposure. Responses to three novel Pf antigens accurately classified whether an individual had been infected within the last 30, 90, or 365 d (cross-validated area under the curve = 0.86-0.93), whereas responses to six antigens accurately estimated an individual's malaria incidence in the prior year. Cross-validated incidence predictions for individuals in different communities provided accurate stratification of exposure between populations and suggest that precise estimates of community exposure can be obtained from sampling a small subset of that community. In addition, serologic incidence predictions from cross-sectional samples characterized heterogeneity within a community similarly to 1 y of continuous passive surveillance. Development of simple ELISA-based assays derived from the successful selection strategy outlined here offers the potential to generate rich epidemiologic surveillance data that will be widely accessible to malaria control programs.

  5. Certified meter data managers provide potent tool : Utilities, customers benefit from accurate energy data

    Energy Technology Data Exchange (ETDEWEB)

    Hall, V.

    2004-02-01

    The use of customer energy information and its importance in building business-to-business and business-to-consumer demographic profiles, and the role of certified meter data management agents, i.e. companies that have created infrastructures to manage large volumes of energy data that can be used to drive marketing to energy customers, is discussed. Short and long-term load management planning, distribution planning, outage management and demand response programs, efforts to streamline billing and create revenue-generating value-added services, are just some of the areas that can benefit from comprehensively collected and accurate consumer data. The article emphasizes the process of certification, the benefits certified meter data management companies can provide to utilities as well as to consumers, their role in disaster recovery management, and characteristics of the way such companies bring the benefits of their operations to their client utilities and consumers. 1 tab.

  6. Can administrative health utilisation data provide an accurate diabetes prevalence estimate for a geographical region?

    Science.gov (United States)

    Chan, Wing Cheuk; Papaconstantinou, Dean; Lee, Mildred; Telfer, Kendra; Jo, Emmanuel; Drury, Paul L; Tobias, Martin

    2018-05-01

    To validate the New Zealand Ministry of Health (MoH) Virtual Diabetes Register (VDR) using longitudinal laboratory results and to develop an improved algorithm for estimating diabetes prevalence at a population level. The assigned diabetes status of individuals based on the 2014 version of the MoH VDR is compared to the diabetes status based on the laboratory results stored in the Auckland regional laboratory result repository (TestSafe) using the New Zealand diabetes diagnostic criteria. The existing VDR algorithm is refined by reviewing the sensitivity and positive predictive value of the each of the VDR algorithm rules individually and as a combination. The diabetes prevalence estimate based on the original 2014 MoH VDR was 17% higher (n = 108,505) than the corresponding TestSafe prevalence estimate (n = 92,707). Compared to the diabetes prevalence based on TestSafe, the original VDR has a sensitivity of 89%, specificity of 96%, positive predictive value of 76% and negative predictive value of 98%. The modified VDR algorithm has improved the positive predictive value by 6.1% and the specificity by 1.4% with modest reductions in sensitivity of 2.2% and negative predictive value of 0.3%. At an aggregated level the overall diabetes prevalence estimated by the modified VDR is 5.7% higher than the corresponding estimate based on TestSafe. The Ministry of Health Virtual Diabetes Register algorithm has been refined to provide a more accurate diabetes prevalence estimate at a population level. The comparison highlights the potential value of a national population long term condition register constructed from both laboratory results and administrative data. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Do physiotherapy staff record treatment time accurately? An observational study.

    Science.gov (United States)

    Bagley, Pam; Hudson, Mary; Green, John; Forster, Anne; Young, John

    2009-09-01

    To assess the reliability of duration of treatment time measured by physiotherapy staff in early-stage stroke patients. Comparison of physiotherapy staff's recording of treatment sessions and video recording. Rehabilitation stroke unit in a general hospital. Thirty-nine stroke patients without trunk control or who were unable to stand with an erect trunk without the support of two therapists recruited to a randomized trial evaluating the Oswestry Standing Frame. Twenty-six physiotherapy staff who were involved in patient treatment. Contemporaneous recording by physiotherapy staff of treatment time (in minutes) compared with video recording. Intraclass correlation with 95% confidence interval and the Bland and Altman method for assessing agreement by calculating the mean difference (standard deviation; 95% confidence interval), reliability coefficient and 95% limits of agreement for the differences between the measurements. The mean duration (standard deviation, SD) of treatment time recorded by physiotherapy staff was 32 (11) minutes compared with 25 (9) minutes as evidenced in the video recording. The mean difference (SD) was -6 (9) minutes (95% confidence interval (CI) -9 to -3). The reliability coefficient was 18 minutes and the 95% limits of agreement were -24 to 12 minutes. Intraclass correlation coefficient for agreement between the two methods was 0.50 (95% CI 0.12 to 0.73). Physiotherapy staff's recording of duration of treatment time was not reliable and was systematically greater than the video recording.

  8. A microbial clock provides an accurate estimate of the postmortem interval in a mouse model system

    Science.gov (United States)

    Metcalf, Jessica L; Wegener Parfrey, Laura; Gonzalez, Antonio; Lauber, Christian L; Knights, Dan; Ackermann, Gail; Humphrey, Gregory C; Gebert, Matthew J; Van Treuren, Will; Berg-Lyons, Donna; Keepers, Kyle; Guo, Yan; Bullard, James; Fierer, Noah; Carter, David O; Knight, Rob

    2013-01-01

    Establishing the time since death is critical in every death investigation, yet existing techniques are susceptible to a range of errors and biases. For example, forensic entomology is widely used to assess the postmortem interval (PMI), but errors can range from days to months. Microbes may provide a novel method for estimating PMI that avoids many of these limitations. Here we show that postmortem microbial community changes are dramatic, measurable, and repeatable in a mouse model system, allowing PMI to be estimated within approximately 3 days over 48 days. Our results provide a detailed understanding of bacterial and microbial eukaryotic ecology within a decomposing corpse system and suggest that microbial community data can be developed into a forensic tool for estimating PMI. DOI: http://dx.doi.org/10.7554/eLife.01104.001 PMID:24137541

  9. Accurate Rapid Lifetime Determination on Time-Gated FLIM Microscopy with Optical Sectioning.

    Science.gov (United States)

    Silva, Susana F; Domingues, José Paulo; Morgado, António Miguel

    2018-01-01

    Time-gated fluorescence lifetime imaging microscopy (FLIM) is a powerful technique to assess the biochemistry of cells and tissues. When applied to living thick samples, it is hampered by the lack of optical sectioning and the need of acquiring many images for an accurate measurement of fluorescence lifetimes. Here, we report on the use of processing techniques to overcome these limitations, minimizing the acquisition time, while providing optical sectioning. We evaluated the application of the HiLo and the rapid lifetime determination (RLD) techniques for accurate measurement of fluorescence lifetimes with optical sectioning. HiLo provides optical sectioning by combining the high-frequency content from a standard image, obtained with uniform illumination, with the low-frequency content of a second image, acquired using structured illumination. Our results show that HiLo produces optical sectioning on thick samples without degrading the accuracy of the measured lifetimes. We also show that instrument response function (IRF) deconvolution can be applied with the RLD technique on HiLo images, improving greatly the accuracy of the measured lifetimes. These results open the possibility of using the RLD technique with pulsed diode laser sources to determine accurately fluorescence lifetimes in the subnanosecond range on thick multilayer samples, providing that offline processing is allowed.

  10. Raman spectroscopy provides a powerful diagnostic tool for accurate determination of albumin glycation.

    Science.gov (United States)

    Dingari, Narahara Chari; Horowitz, Gary L; Kang, Jeon Woong; Dasari, Ramachandra R; Barman, Ishan

    2012-01-01

    We present the first demonstration of glycated albumin detection and quantification using Raman spectroscopy without the addition of reagents. Glycated albumin is an important marker for monitoring the long-term glycemic history of diabetics, especially as its concentrations, in contrast to glycated hemoglobin levels, are unaffected by changes in erythrocyte life times. Clinically, glycated albumin concentrations show a strong correlation with the development of serious diabetes complications including nephropathy and retinopathy. In this article, we propose and evaluate the efficacy of Raman spectroscopy for determination of this important analyte. By utilizing the pre-concentration obtained through drop-coating deposition, we show that glycation of albumin leads to subtle, but consistent, changes in vibrational features, which with the help of multivariate classification techniques can be used to discriminate glycated albumin from the unglycated variant with 100% accuracy. Moreover, we demonstrate that the calibration model developed on the glycated albumin spectral dataset shows high predictive power, even at substantially lower concentrations than those typically encountered in clinical practice. In fact, the limit of detection for glycated albumin measurements is calculated to be approximately four times lower than its minimum physiological concentration. Importantly, in relation to the existing detection methods for glycated albumin, the proposed method is also completely reagent-free, requires barely any sample preparation and has the potential for simultaneous determination of glycated hemoglobin levels as well. Given these key advantages, we believe that the proposed approach can provide a uniquely powerful tool for quantification of glycation status of proteins in biopharmaceutical development as well as for glycemic marker determination in routine clinical diagnostics in the future.

  11. Raman Spectroscopy Provides a Powerful Diagnostic Tool for Accurate Determination of Albumin Glycation

    Science.gov (United States)

    Dingari, Narahara Chari; Horowitz, Gary L.; Kang, Jeon Woong; Dasari, Ramachandra R.; Barman, Ishan

    2012-01-01

    We present the first demonstration of glycated albumin detection and quantification using Raman spectroscopy without the addition of reagents. Glycated albumin is an important marker for monitoring the long-term glycemic history of diabetics, especially as its concentrations, in contrast to glycated hemoglobin levels, are unaffected by changes in erythrocyte life times. Clinically, glycated albumin concentrations show a strong correlation with the development of serious diabetes complications including nephropathy and retinopathy. In this article, we propose and evaluate the efficacy of Raman spectroscopy for determination of this important analyte. By utilizing the pre-concentration obtained through drop-coating deposition, we show that glycation of albumin leads to subtle, but consistent, changes in vibrational features, which with the help of multivariate classification techniques can be used to discriminate glycated albumin from the unglycated variant with 100% accuracy. Moreover, we demonstrate that the calibration model developed on the glycated albumin spectral dataset shows high predictive power, even at substantially lower concentrations than those typically encountered in clinical practice. In fact, the limit of detection for glycated albumin measurements is calculated to be approximately four times lower than its minimum physiological concentration. Importantly, in relation to the existing detection methods for glycated albumin, the proposed method is also completely reagent-free, requires barely any sample preparation and has the potential for simultaneous determination of glycated hemoglobin levels as well. Given these key advantages, we believe that the proposed approach can provide a uniquely powerful tool for quantification of glycation status of proteins in biopharmaceutical development as well as for glycemic marker determination in routine clinical diagnostics in the future. PMID:22393405

  12. Activity assays and immunoassays for plasma Renin and prorenin: information provided and precautions necessary for accurate measurement

    DEFF Research Database (Denmark)

    Campbell, Duncan J; Nussberger, Juerg; Stowasser, Michael

    2009-01-01

    into focus the differences in information provided by activity assays and immunoassays for renin and prorenin measurement and has drawn attention to the need for precautions to ensure their accurate measurement. CONTENT: Renin activity assays and immunoassays provide related but different information...... provided by these assays and of the precautions necessary to ensure their accuracy....

  13. Accurate Lithium-ion battery parameter estimation with continuous-time system identification methods

    International Nuclear Information System (INIS)

    Xia, Bing; Zhao, Xin; Callafon, Raymond de; Garnier, Hugues; Nguyen, Truong; Mi, Chris

    2016-01-01

    Highlights: • Continuous-time system identification is applied in Lithium-ion battery modeling. • Continuous-time and discrete-time identification methods are compared in detail. • The instrumental variable method is employed to further improve the estimation. • Simulations and experiments validate the advantages of continuous-time methods. - Abstract: The modeling of Lithium-ion batteries usually utilizes discrete-time system identification methods to estimate parameters of discrete models. However, in real applications, there is a fundamental limitation of the discrete-time methods in dealing with sensitivity when the system is stiff and the storage resolutions are limited. To overcome this problem, this paper adopts direct continuous-time system identification methods to estimate the parameters of equivalent circuit models for Lithium-ion batteries. Compared with discrete-time system identification methods, the continuous-time system identification methods provide more accurate estimates to both fast and slow dynamics in battery systems and are less sensitive to disturbances. A case of a 2"n"d-order equivalent circuit model is studied which shows that the continuous-time estimates are more robust to high sampling rates, measurement noises and rounding errors. In addition, the estimation by the conventional continuous-time least squares method is further improved in the case of noisy output measurement by introducing the instrumental variable method. Simulation and experiment results validate the analysis and demonstrate the advantages of the continuous-time system identification methods in battery applications.

  14. Can Raters with Reduced Job Descriptive Information Provide Accurate Position Analysis Questionnaire (PAQ) Ratings?

    Science.gov (United States)

    Friedman, Lee; Harvey, Robert J.

    1986-01-01

    Job-naive raters provided with job descriptive information made Position Analysis Questionnaire (PAQ) ratings which were validated against ratings of job analysts who were also job content experts. None of the reduced job descriptive information conditions enabled job-naive raters to obtain either acceptable levels of convergent validity with…

  15. Raman Spectroscopy Provides a Powerful Diagnostic Tool for Accurate Determination of Albumin Glycation

    OpenAIRE

    Dingari, Narahara Chari; Kang, Jeon Woong; Dasari, Ramachandra R.; Barman, Ishan; Horowitz, Gary Leigh

    2012-01-01

    We present the first demonstration of glycated albumin detection and quantification using Raman spectroscopy without the addition of reagents. Glycated albumin is an important marker for monitoring the long-term glycemic history of diabetics, especially as its concentrations, in contrast to glycated hemoglobin levels, are unaffected by changes in erythrocyte life times. Clinically, glycated albumin concentrations show a strong correlation with the development of serious diabetes complications...

  16. The Space-Time Conservative Schemes for Large-Scale, Time-Accurate Flow Simulations with Tetrahedral Meshes

    Science.gov (United States)

    Venkatachari, Balaji Shankar; Streett, Craig L.; Chang, Chau-Lyan; Friedlander, David J.; Wang, Xiao-Yen; Chang, Sin-Chung

    2016-01-01

    Despite decades of development of unstructured mesh methods, high-fidelity time-accurate simulations are still predominantly carried out on structured, or unstructured hexahedral meshes by using high-order finite-difference, weighted essentially non-oscillatory (WENO), or hybrid schemes formed by their combinations. In this work, the space-time conservation element solution element (CESE) method is used to simulate several flow problems including supersonic jet/shock interaction and its impact on launch vehicle acoustics, and direct numerical simulations of turbulent flows using tetrahedral meshes. This paper provides a status report for the continuing development of the space-time conservation element solution element (CESE) numerical and software framework under the Revolutionary Computational Aerosciences (RCA) project. Solution accuracy and large-scale parallel performance of the numerical framework is assessed with the goal of providing a viable paradigm for future high-fidelity flow physics simulations.

  17. Fiber diffraction of skin and nails provides an accurate diagnosis of malignancies

    International Nuclear Information System (INIS)

    James, Veronica J.

    2009-01-01

    An early diagnosis of malignancies correlates directly with a better prognosis. Yet for many malignancies there are no readily available, noninvasive, cost-effective diagnostic tests with patients often presenting too late for effective treatment. This article describes for the first time the use of fiber diffraction patterns of skin or fingernails, using X-ray sources, as a biometric diagnostic method for detecting neoplastic disorders including but not limited to melanoma, breast, colon and prostate cancers. With suitable further development, an early low-cost, totally noninvasive yet reliable diagnostic test could be conducted on a regular basis in local radiology facilities, as a confirmatory test for other diagnostic procedures or as a mass screening test using suitable small angle X-ray beam-lines at synchrotrons.

  18. Patient Satisfaction Is Associated With Time With Provider But Not Clinic Wait Time Among Orthopedic Patients.

    Science.gov (United States)

    Patterson, Brendan M; Eskildsen, Scott M; Clement, R Carter; Lin, Feng-Chang; Olcott, Christopher W; Del Gaizo, Daniel J; Tennant, Joshua N

    2017-01-01

    Clinic wait time is considered an important predictor of patient satisfaction. The goal of this study was to determine whether patient satisfaction among orthopedic patients is associated with clinic wait time and time with the provider. The authors prospectively enrolled 182 patients at their outpatient orthopedic clinic. Clinic wait time was defined as the time between patient check-in and being seen by the surgeon. Time spent with the provider was defined as the total time the patient spent in the examination room with the surgeon. The Consumer Assessment of Healthcare Providers and Systems survey was used to measure patient satisfaction. Factors associated with increased patient satisfaction included patient age and increased time with the surgeon (P=.024 and P=.037, respectively), but not clinic wait time (P=.625). Perceived wait time was subject to a high level of error, and most patients did not accurately report whether they had been waiting longer than 15 minutes to see a provider until they had waited at least 60 minutes (P=.007). If the results of the current study are generalizable, time with the surgeon is associated with patient satisfaction in orthopedic clinics, but wait time is not. Further, the study findings showed that patients in this setting did not have an accurate perception of actual wait time, with many patients underestimating the time they waited to see a provider. Thus, a potential strategy for improving patient satisfaction is to spend more time with each patient, even at the expense of increased wait time. [Orthopedics. 2017; 40(1):43-48.]. Copyright 2016, SLACK Incorporated.

  19. Does universal 16S rRNA gene amplicon sequencing of environmental communities provide an accurate description of nitrifying guilds?

    DEFF Research Database (Denmark)

    Diwan, Vaibhav; Albrechtsen, Hans-Jørgen; Smets, Barth F.

    2018-01-01

    amplicon sequencing and from guild targeted approaches. The universal amplicon sequencing provided 1) accurate estimates of nitrifier composition, 2) clustering of the samples based on these compositions consistent with sample origin, 3) estimates of the relative abundance of the guilds correlated...

  20. A solution for measuring accurate reaction time to visual stimuli realized with a programmable microcontroller.

    Science.gov (United States)

    Ohyanagi, Toshio; Sengoku, Yasuhito

    2010-02-01

    This article presents a new solution for measuring accurate reaction time (SMART) to visual stimuli. The SMART is a USB device realized with a Cypress Programmable System-on-Chip (PSoC) mixed-signal array programmable microcontroller. A brief overview of the hardware and firmware of the PSoC is provided, together with the results of three experiments. In Experiment 1, we investigated the timing accuracy of the SMART in measuring reaction time (RT) under different conditions of operating systems (OSs; Windows XP or Vista) and monitor displays (a CRT or an LCD). The results indicated that the timing error in measuring RT by the SMART was less than 2 msec, on average, under all combinations of OS and display and that the SMART was tolerant to jitter and noise. In Experiment 2, we tested the SMART with 8 participants. The results indicated that there was no significant difference among RTs obtained with the SMART under the different conditions of OS and display. In Experiment 3, we used Microsoft (MS) PowerPoint to present visual stimuli on the display. We found no significant difference in RTs obtained using MS DirectX technology versus using the PowerPoint file with the SMART. We are certain that the SMART is a simple and practical solution for measuring RTs accurately. Although there are some restrictions in using the SMART with RT paradigms, the SMART is capable of providing both researchers and health professionals working in clinical settings with new ways of using RT paradigms in their work.

  1. A discontinous Galerkin finite element method with an efficient time integration scheme for accurate simulations

    KAUST Repository

    Liu, Meilin; Bagci, Hakan

    2011-01-01

    A discontinuous Galerkin finite element method (DG-FEM) with a highly-accurate time integration scheme is presented. The scheme achieves its high accuracy using numerically constructed predictor-corrector integration coefficients. Numerical results

  2. Time-Accurate Simulations of Synthetic Jet-Based Flow Control for An Axisymmetric Spinning Body

    National Research Council Canada - National Science Library

    Sahu, Jubaraj

    2004-01-01

    .... A time-accurate Navier-Stokes computational technique has been used to obtain numerical solutions for the unsteady jet-interaction flow field for a spinning projectile at a subsonic speed, Mach...

  3. Precise and accurate train run data: Approximation of actual arrival and departure times

    DEFF Research Database (Denmark)

    Richter, Troels; Landex, Alex; Andersen, Jonas Lohmann Elkjær

    with the approximated actual arrival and departure times. As a result, all future statistics can now either be based on track circuit data with high precision or approximated actual arrival times with a high accuracy. Consequently, performance analysis will be more accurate, punctuality statistics more correct, KPI...

  4. A high-order time-accurate interrogation method for time-resolved PIV

    International Nuclear Information System (INIS)

    Lynch, Kyle; Scarano, Fulvio

    2013-01-01

    A novel method is introduced for increasing the accuracy and extending the dynamic range of time-resolved particle image velocimetry (PIV). The approach extends the concept of particle tracking velocimetry by multiple frames to the pattern tracking by cross-correlation analysis as employed in PIV. The working principle is based on tracking the patterned fluid element, within a chosen interrogation window, along its individual trajectory throughout an image sequence. In contrast to image-pair interrogation methods, the fluid trajectory correlation concept deals with variable velocity along curved trajectories and non-zero tangential acceleration during the observed time interval. As a result, the velocity magnitude and its direction are allowed to evolve in a nonlinear fashion along the fluid element trajectory. The continuum deformation (namely spatial derivatives of the velocity vector) is accounted for by adopting local image deformation. The principle offers important reductions of the measurement error based on three main points: by enlarging the temporal measurement interval, the relative error becomes reduced; secondly, the random and peak-locking errors are reduced by the use of least-squares polynomial fits to individual trajectories; finally, the introduction of high-order (nonlinear) fitting functions provides the basis for reducing the truncation error. Lastly, the instantaneous velocity is evaluated as the temporal derivative of the polynomial representation of the fluid parcel position in time. The principal features of this algorithm are compared with a single-pair iterative image deformation method. Synthetic image sequences are considered with steady flow (translation, shear and rotation) illustrating the increase of measurement precision. An experimental data set obtained by time-resolved PIV measurements of a circular jet is used to verify the robustness of the method on image sequences affected by camera noise and three-dimensional motions. In

  5. A discontinous Galerkin finite element method with an efficient time integration scheme for accurate simulations

    KAUST Repository

    Liu, Meilin

    2011-07-01

    A discontinuous Galerkin finite element method (DG-FEM) with a highly-accurate time integration scheme is presented. The scheme achieves its high accuracy using numerically constructed predictor-corrector integration coefficients. Numerical results show that this new time integration scheme uses considerably larger time steps than the fourth-order Runge-Kutta method when combined with a DG-FEM using higher-order spatial discretization/basis functions for high accuracy. © 2011 IEEE.

  6. Daily FOUR score assessment provides accurate prognosis of long-term outcome in out-of-hospital cardiac arrest.

    Science.gov (United States)

    Weiss, N; Venot, M; Verdonk, F; Chardon, A; Le Guennec, L; Llerena, M C; Raimbourg, Q; Taldir, G; Luque, Y; Fagon, J-Y; Guerot, E; Diehl, J-L

    2015-05-01

    The accurate prediction of outcome after out-of-hospital cardiac arrest (OHCA) is of major importance. The recently described Full Outline of UnResponsiveness (FOUR) is well adapted to mechanically ventilated patients and does not depend on verbal response. To evaluate the ability of FOUR assessed by intensivists to accurately predict outcome in OHCA. We prospectively identified patients admitted for OHCA with a Glasgow Coma Scale below 8. Neurological assessment was performed daily. Outcome was evaluated at 6 months using Glasgow-Pittsburgh Cerebral Performance Categories (GP-CPC). Eighty-five patients were included. At 6 months, 19 patients (22%) had a favorable outcome, GP-CPC 1-2, and 66 (78%) had an unfavorable outcome, GP-CPC 3-5. Compared to both brainstem responses at day 3 and evolution of Glasgow Coma Scale, evolution of FOUR score over the three first days was able to predict unfavorable outcome more precisely. Thus, absence of improvement or worsening from day 1 to day 3 of FOUR had 0.88 (0.79-0.97) specificity, 0.71 (0.66-0.76) sensitivity, 0.94 (0.84-1.00) PPV and 0.54 (0.49-0.59) NPV to predict unfavorable outcome. Similarly, the brainstem response of FOUR score at 0 evaluated at day 3 had 0.94 (0.89-0.99) specificity, 0.60 (0.50-0.70) sensitivity, 0.96 (0.92-1.00) PPV and 0.47 (0.37-0.57) NPV to predict unfavorable outcome. The absence of improvement or worsening from day 1 to day 3 of FOUR evaluated by intensivists provides an accurate prognosis of poor neurological outcome in OHCA. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  7. Towards cycle-accurate performance predictions for real-time embedded systems

    NARCIS (Netherlands)

    Triantafyllidis, K.; Bondarev, E.; With, de P.H.N.; Arabnia, H.R.; Deligiannidis, L.; Jandieri, G.

    2013-01-01

    In this paper we present a model-based performance analysis method for component-based real-time systems, featuring cycle-accurate predictions of latencies and enhanced system robustness. The method incorporates the following phases: (a) instruction-level profiling of SW components, (b) modeling the

  8. Concurrent chart review provides more accurate documentation and increased calculated case mix index, severity of illness, and risk of mortality.

    Science.gov (United States)

    Frazee, Richard C; Matejicka, Anthony V; Abernathy, Stephen W; Davis, Matthew; Isbell, Travis S; Regner, Justin L; Smith, Randall W; Jupiter, Daniel C; Papaconstantinou, Harry T

    2015-04-01

    Case mix index (CMI) is calculated to determine the relative value assigned to a Diagnosis-Related Group. Accurate documentation of patient complications and comorbidities and major complications and comorbidities changes CMI and can affect hospital reimbursement and future pay for performance metrics. Starting in 2010, a physician panel concurrently reviewed the documentation of the trauma/acute care surgeons. Clarifications of the Centers for Medicare and Medicaid Services term-specific documentation were made by the panel, and the surgeon could incorporate or decline the clinical queries. A retrospective review of trauma/acute care inpatients was performed. The mean severity of illness, risk of mortality, and CMI from 2009 were compared with the 3 subsequent years. Mean length of stay and mean Injury Severity Score by year were listed as measures of patient acuity. Statistical analysis was performed using ANOVA and t-test, with p reimbursement and more accurately stratify outcomes measures for care providers. Copyright © 2015 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Can We Accurately Time the Administration of Antenatal Corticosteroids for Preterm Labor?

    Directory of Open Access Journals (Sweden)

    Paola Aghajanian

    2016-01-01

    Full Text Available Background. Accurate timing of antenatal corticosteroids (ACS has resulted in improved neonatal outcomes. Objectives. Our primary objective was to determine predictors for optimal timing of ACS in women presenting with spontaneous preterm labor. Study Design. A retrospective cohort study of women receiving ACS for spontaneous preterm birth was conducted. Women were included if they presented with preterm labor or preterm premature rupture of membranes. Accurate timing of ACS was defined as administration within 7 days of delivery. Maternal demographic and obstetrics characteristics were compared between the groups receiving ACS ≤7 days and >7 days from delivery. Statistical analyses were performed using parametric and nonparametric tests. P<0.05 was considered significant. Results. The study included 215 subjects. Median latency from ACS administration to delivery was 6 days (IQR 32. Accurate timing of ACS occurred in 113 (53% women and was associated with rupture of membranes (OR 13.8, 95% CI 5.9–32.6, cervical change (OR 7.1, 95% CI 3.0–17.1, and cervical dilation ≥ 2 cm (OR 3.9, 95% CI 1.5–10.3. Conclusions. Rupture of membranes, cervical change, and cervical dilation ≥ 2 cm were strong predictors of optimal timing. 53% of women with preterm labor received ACS optimally.

  10. Time Accurate Unsteady Pressure Loads Simulated for the Space Launch System at a Wind Tunnel Condition

    Science.gov (United States)

    Alter, Stephen J.; Brauckmann, Gregory J.; Kleb, Bil; Streett, Craig L; Glass, Christopher E.; Schuster, David M.

    2015-01-01

    Using the Fully Unstructured Three-Dimensional (FUN3D) computational fluid dynamics code, an unsteady, time-accurate flow field about a Space Launch System configuration was simulated at a transonic wind tunnel condition (Mach = 0.9). Delayed detached eddy simulation combined with Reynolds Averaged Naiver-Stokes and a Spallart-Almaras turbulence model were employed for the simulation. Second order accurate time evolution scheme was used to simulate the flow field, with a minimum of 0.2 seconds of simulated time to as much as 1.4 seconds. Data was collected at 480 pressure taps at locations, 139 of which matched a 3% wind tunnel model, tested in the Transonic Dynamic Tunnel (TDT) facility at NASA Langley Research Center. Comparisons between computation and experiment showed agreement within 5% in terms of location for peak RMS levels, and 20% for frequency and magnitude of power spectral densities. Grid resolution and time step sensitivity studies were performed to identify methods for improved accuracy comparisons to wind tunnel data. With limited computational resources, accurate trends for reduced vibratory loads on the vehicle were observed. Exploratory methods such as determining minimized computed errors based on CFL number and sub-iterations, as well as evaluating frequency content of the unsteady pressures and evaluation of oscillatory shock structures were used in this study to enhance computational efficiency and solution accuracy. These techniques enabled development of a set of best practices, for the evaluation of future flight vehicle designs in terms of vibratory loads.

  11. Joint accurate time and stable frequency distribution infrastructure sharing fiber footprint with research network

    Czech Academy of Sciences Publication Activity Database

    Vojtěch, J.; Šlapák, M.; Škoda, P.; Radil, J.; Havliš, O.; Altmann, M.; Münster, P.; Velč, R.; Kundrát, J.; Altmannová, L.; Vohnout, R.; Horváth, T.; Hůla, M.; Smotlacha, V.; Čížek, Martin; Pravdová, Lenka; Řeřucha, Šimon; Hrabina, Jan; Číp, Ondřej

    2017-01-01

    Roč. 56, č. 2 (2017), s. 1-7, č. článku 027101. ISSN 0091-3286 R&D Projects: GA ČR GB14-36681G Institutional support: RVO:68081731 Keywords : accurate time * stable frequency * wavelength division multiplexing * bidirectional reciprocal path * Sagnac effect Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: Optics (including laser optics and quantum optics) Impact factor: 1.082, year: 2016

  12. An accurate approximate solution of optimal sequential age replacement policy for a finite-time horizon

    International Nuclear Information System (INIS)

    Jiang, R.

    2009-01-01

    It is difficult to find the optimal solution of the sequential age replacement policy for a finite-time horizon. This paper presents an accurate approximation to find an approximate optimal solution of the sequential replacement policy. The proposed approximation is computationally simple and suitable for any failure distribution. Their accuracy is illustrated by two examples. Based on the approximate solution, an approximate estimate for the total cost is derived.

  13. Atomistic simulations of materials: Methods for accurate potentials and realistic time scales

    Science.gov (United States)

    Tiwary, Pratyush

    This thesis deals with achieving more realistic atomistic simulations of materials, by developing accurate and robust force-fields, and algorithms for practical time scales. I develop a formalism for generating interatomic potentials for simulating atomistic phenomena occurring at energy scales ranging from lattice vibrations to crystal defects to high-energy collisions. This is done by fitting against an extensive database of ab initio results, as well as to experimental measurements for mixed oxide nuclear fuels. The applicability of these interactions to a variety of mixed environments beyond the fitting domain is also assessed. The employed formalism makes these potentials applicable across all interatomic distances without the need for any ambiguous splining to the well-established short-range Ziegler-Biersack-Littmark universal pair potential. We expect these to be reliable potentials for carrying out damage simulations (and molecular dynamics simulations in general) in nuclear fuels of varying compositions for all relevant atomic collision energies. A hybrid stochastic and deterministic algorithm is proposed that while maintaining fully atomistic resolution, allows one to achieve milliseconds and longer time scales for several thousands of atoms. The method exploits the rare event nature of the dynamics like other such methods, but goes beyond them by (i) not having to pick a scheme for biasing the energy landscape, (ii) providing control on the accuracy of the boosted time scale, (iii) not assuming any harmonic transition state theory (HTST), and (iv) not having to identify collective coordinates or interesting degrees of freedom. The method is validated by calculating diffusion constants for vacancy-mediated diffusion in iron metal at low temperatures, and comparing against brute-force high temperature molecular dynamics. We also calculate diffusion constants for vacancy diffusion in tantalum metal, where we compare against low-temperature HTST as well

  14. Late Miocene climate and time scale reconciliation: Accurate orbital calibration from a deep-sea perspective

    Science.gov (United States)

    Drury, Anna Joy; Westerhold, Thomas; Frederichs, Thomas; Tian, Jun; Wilkens, Roy; Channell, James E. T.; Evans, Helen; John, Cédric M.; Lyle, Mitch; Röhl, Ursula

    2017-10-01

    Accurate age control of the late Tortonian to early Messinian (8.3-6.0 Ma) is essential to ascertain the origin of benthic foraminiferal δ18O trends and the late Miocene carbon isotope shift (LMCIS), and to examine temporal relationships between the deep-sea, terrasphere and cryosphere. The current Tortonian-Messinian Geological Time Scale (GTS2012) is based on astronomically calibrated Mediterranean sections; however, no comparable non-Mediterranean stratigraphies exist for 8-6 Ma suitable for testing the GTS2012. Here, we present the first high-resolution, astronomically tuned benthic stable isotope stratigraphy (1.5 kyr resolution) and magnetostratigraphy from a single deep-sea location (IODP Site U1337, equatorial Pacific Ocean), which provides unprecedented insight into climate evolution from 8.3-6.0 Ma. The astronomically calibrated magnetostratigraphy provides robust ages, which differ by 2-50 kyr relative to the GTS2012 for polarity Chrons C3An.1n to C4r.1r, and eliminates the exceptionally high South Atlantic spreading rates based on the GTS2012 during Chron C3Bn. We show that the LMCIS was globally synchronous within 2 kyr, and provide astronomically calibrated ages anchored to the GPTS for its onset (7.537 Ma; 50% from base Chron C4n.1n) and termination (6.727 Ma; 11% from base Chron C3An.2n), confirming that the terrestrial C3:C4 shift could not have driven the LMCIS. The benthic records show that the transition into the 41-kyr world, when obliquity strongly influenced climate variability, already occurred at 7.7 Ma and further strengthened at 6.4 Ma. Previously unseen, distinctive, asymmetric saw-tooth patterns in benthic δ18O imply that high-latitude forcing played an important role in late Miocene climate dynamics from 7.7-6.9 Ma. This new integrated deep-sea stratigraphy from Site U1337 can act as a new stable isotope and magnetic polarity reference section for the 8.3-6.0 Ma interval.

  15. Time-driven Activity-based Costing More Accurately Reflects Costs in Arthroplasty Surgery.

    Science.gov (United States)

    Akhavan, Sina; Ward, Lorrayne; Bozic, Kevin J

    2016-01-01

    categories with the most variability between TA and TDABC estimates were operating room services and room and board. Traditional hospital cost accounting systems overestimate the costs associated with many surgical procedures, including primary TJA. TDABC provides a more accurate measure of true resource use associated with TJAs and can be used to identify high-cost/high-variability processes that can be targeted for process/quality improvement. Level III, therapeutic study.

  16. Simplifying ART cohort monitoring: Can pharmacy stocks provide accurate estimates of patients retained on antiretroviral therapy in Malawi?

    Directory of Open Access Journals (Sweden)

    Tweya Hannock

    2012-07-01

    Full Text Available Abstract Background Routine monitoring of patients on antiretroviral therapy (ART is crucial for measuring program success and accurate drug forecasting. However, compiling data from patient registers to measure retention in ART is labour-intensive. To address this challenge, we conducted a pilot study in Malawi to assess whether patient ART retention could be determined using pharmacy records as compared to estimates of retention based on standardized paper- or electronic based cohort reports. Methods Twelve ART facilities were included in the study: six used paper-based registers and six used electronic data systems. One ART facility implemented an electronic data system in quarter three and was included as a paper-based system facility in quarter two only. Routine patient retention cohort reports, paper or electronic, were collected from facilities for both quarter two [April–June] and quarter three [July–September], 2010. Pharmacy stock data were also collected from the 12 ART facilities over the same period. Numbers of ART continuation bottles recorded on pharmacy stock cards at the beginning and end of each quarter were documented. These pharmacy data were used to calculate the total bottles dispensed to patients in each quarter with intent to estimate the number of patients retained on ART. Information for time required to determine ART retention was gathered through interviews with clinicians tasked with compiling the data. Results Among ART clinics with paper-based systems, three of six facilities in quarter two and four of five facilities in quarter three had similar numbers of patients retained on ART comparing cohort reports to pharmacy stock records. In ART clinics with electronic systems, five of six facilities in quarter two and five of seven facilities in quarter three had similar numbers of patients retained on ART when comparing retention numbers from electronically generated cohort reports to pharmacy stock records. Among

  17. Producing accurate wave propagation time histories using the global matrix method

    International Nuclear Information System (INIS)

    Obenchain, Matthew B; Cesnik, Carlos E S

    2013-01-01

    This paper presents a reliable method for producing accurate displacement time histories for wave propagation in laminated plates using the global matrix method. The existence of inward and outward propagating waves in the general solution is highlighted while examining the axisymmetric case of a circular actuator on an aluminum plate. Problems with previous attempts to isolate the outward wave for anisotropic laminates are shown. The updated method develops a correction signal that can be added to the original time history solution to cancel the inward wave and leave only the outward propagating wave. The paper demonstrates the effectiveness of the new method for circular and square actuators bonded to the surface of isotropic laminates, and these results are compared with exact solutions. Results for circular actuators on cross-ply laminates are also presented and compared with experimental results, showing the ability of the new method to successfully capture the displacement time histories for composite laminates. (paper)

  18. Decision tree for accurate infection timing in individuals newly diagnosed with HIV-1 infection.

    Science.gov (United States)

    Verhofstede, Chris; Fransen, Katrien; Van Den Heuvel, Annelies; Van Laethem, Kristel; Ruelle, Jean; Vancutsem, Ellen; Stoffels, Karolien; Van den Wijngaert, Sigi; Delforge, Marie-Luce; Vaira, Dolores; Hebberecht, Laura; Schauvliege, Marlies; Mortier, Virginie; Dauwe, Kenny; Callens, Steven

    2017-11-29

    There is today no gold standard method to accurately define the time passed since infection at HIV diagnosis. Infection timing and incidence measurement is however essential to better monitor the dynamics of local epidemics and the effect of prevention initiatives. Three methods for infection timing were evaluated using 237 serial samples from documented seroconversions and 566 cross sectional samples from newly diagnosed patients: identification of antibodies against the HIV p31 protein in INNO-LIA, SediaTM BED CEIA and SediaTM LAg-Avidity EIA. A multi-assay decision tree for infection timing was developed. Clear differences in recency window between BED CEIA, LAg-Avidity EIA and p31 antibody presence were observed with a switch from recent to long term infection a median of 169.5, 108.0 and 64.5 days after collection of the pre-seroconversion sample respectively. BED showed high reliability for identification of long term infections while LAg-Avidity is highly accurate for identification of recent infections. Using BED as initial assay to identify the long term infections and LAg-Avidity as a confirmatory assay for those classified as recent infection by BED, explores the strengths of both while reduces the workload. The short recency window of p31 antibodies allows to discriminate very early from early infections based on this marker. BED recent infection results not confirmed by LAg-Avidity are considered to reflect a period more distant from the infection time. False recency predictions in this group can be minimized by elimination of patients with a CD4 count of less than 100 cells/mm3 or without no p31 antibodies. For 566 cross sectional sample the outcome of the decision tree confirmed the infection timing based on the results of all 3 markers but reduced the overall cost from 13.2 USD to 5.2 USD per sample. A step-wise multi assay decision tree allows accurate timing of the HIV infection at diagnosis at affordable effort and cost and can be an important

  19. Renal contrast-enhanced MR angiography: timing errors and accurate depiction of renal artery origins.

    Science.gov (United States)

    Schmidt, Maria A; Morgan, Robert

    2008-10-01

    To investigate bolus timing artifacts that impair depiction of renal arteries at contrast material-enhanced magnetic resonance (MR) angiography and to determine the effect of contrast agent infusion rates on artifact generation. Renal contrast-enhanced MR angiography was simulated for a variety of infusion schemes, assuming both correct and incorrect timing between data acquisition and contrast agent injection. In addition, the ethics committee approved the retrospective evaluation of clinical breath-hold renal contrast-enhanced MR angiographic studies obtained with automated detection of contrast agent arrival. Twenty-two studies were evaluated for their ability to depict the origin of renal arteries in patent vessels and for any signs of timing errors. Simulations showed that a completely artifactual stenosis or an artifactual overestimation of an existing stenosis at the renal artery origin can be caused by timing errors of the order of 5 seconds in examinations performed with contrast agent infusion rates compatible with or higher than those of hand injections. Lower infusion rates make the studies more likely to accurately depict the origin of the renal arteries. In approximately one-third of all clinical examinations, different contrast agent uptake rates were detected on the left and right sides of the body, and thus allowed us to confirm that it is often impossible to optimize depiction of both renal arteries. In three renal arteries, a signal void was found at the origin in a patent vessel, and delayed contrast agent arrival was confirmed. Computer simulations and clinical examinations showed that timing errors impair the accurate depiction of renal artery origins. (c) RSNA, 2008.

  20. Time-Accurate Unsteady Pressure Loads Simulated for the Space Launch System at Wind Tunnel Conditions

    Science.gov (United States)

    Alter, Stephen J.; Brauckmann, Gregory J.; Kleb, William L.; Glass, Christopher E.; Streett, Craig L.; Schuster, David M.

    2015-01-01

    A transonic flow field about a Space Launch System (SLS) configuration was simulated with the Fully Unstructured Three-Dimensional (FUN3D) computational fluid dynamics (CFD) code at wind tunnel conditions. Unsteady, time-accurate computations were performed using second-order Delayed Detached Eddy Simulation (DDES) for up to 1.5 physical seconds. The surface pressure time history was collected at 619 locations, 169 of which matched locations on a 2.5 percent wind tunnel model that was tested in the 11 ft. x 11 ft. test section of the NASA Ames Research Center's Unitary Plan Wind Tunnel. Comparisons between computation and experiment showed that the peak surface pressure RMS level occurs behind the forward attach hardware, and good agreement for frequency and power was obtained in this region. Computational domain, grid resolution, and time step sensitivity studies were performed. These included an investigation of pseudo-time sub-iteration convergence. Using these sensitivity studies and experimental data comparisons, a set of best practices to date have been established for FUN3D simulations for SLS launch vehicle analysis. To the author's knowledge, this is the first time DDES has been used in a systematic approach and establish simulation time needed, to analyze unsteady pressure loads on a space launch vehicle such as the NASA SLS.

  1. Real-time water quality monitoring and providing water quality ...

    Science.gov (United States)

    EPA and the U.S. Geological Survey (USGS) have initiated the “Village Blue” research project to provide real-time water quality monitoring data to the Baltimore community and increase public awareness about local water quality in Baltimore Harbor and the Chesapeake Bay. The Village Blue demonstration project complements work that a number of state and local organizations are doing to make Baltimore Harbor “swimmable and fishable” 2 by 2020. Village Blue is designed to build upon EPA’s “Village Green” project which provides real-time air quality information to communities in six locations across the country. The presentation, “Real-time water quality monitoring and providing water quality information to the Baltimore Community”, summarizes the Village Blue real-time water quality monitoring project being developed for the Baltimore Harbor.

  2. A Time--Independent Born--Oppenheimer Approximation with Exponentially Accurate Error Estimates

    CERN Document Server

    Hagedorn, G A

    2004-01-01

    We consider a simple molecular--type quantum system in which the nuclei have one degree of freedom and the electrons have two levels. The Hamiltonian has the form \\[ H(\\epsilon)\\ =\\ -\\,\\frac{\\epsilon^4}2\\, \\frac{\\partial^2\\phantom{i}}{\\partial y^2}\\ +\\ h(y), \\] where $h(y)$ is a $2\\times 2$ real symmetric matrix. Near a local minimum of an electron level ${\\cal E}(y)$ that is not at a level crossing, we construct quasimodes that are exponentially accurate in the square of the Born--Oppenheimer parameter $\\epsilon$ by optimal truncation of the Rayleigh--Schr\\"odinger series. That is, we construct $E_\\epsilon$ and $\\Psi_\\epsilon$, such that $\\|\\Psi_\\epsilon\\|\\,=\\,O(1)$ and \\[ \\|\\,(H(\\epsilon)\\,-\\,E_\\epsilon))\\,\\Psi_\\epsilon\\,\\|\\ 0. \\

  3. Disambiguating past events: Accurate source memory for time and context depends on different retrieval processes.

    Science.gov (United States)

    Persson, Bjorn M; Ainge, James A; O'Connor, Akira R

    2016-07-01

    Current animal models of episodic memory are usually based on demonstrating integrated memory for what happened, where it happened, and when an event took place. These models aim to capture the testable features of the definition of human episodic memory which stresses the temporal component of the memory as a unique piece of source information that allows us to disambiguate one memory from another. Recently though, it has been suggested that a more accurate model of human episodic memory would include contextual rather than temporal source information, as humans' memory for time is relatively poor. Here, two experiments were carried out investigating human memory for temporal and contextual source information, along with the underlying dual process retrieval processes, using an immersive virtual environment paired with a 'Remember-Know' memory task. Experiment 1 (n=28) showed that contextual information could only be retrieved accurately using recollection, while temporal information could be retrieved using either recollection or familiarity. Experiment 2 (n=24), which used a more difficult task, resulting in reduced item recognition rates and therefore less potential for contamination by ceiling effects, replicated the pattern of results from Experiment 1. Dual process theory predicts that it should only be possible to retrieve source context from an event using recollection, and our results are consistent with this prediction. That temporal information can be retrieved using familiarity alone suggests that it may be incorrect to view temporal context as analogous to other typically used source contexts. This latter finding supports the alternative proposal that time since presentation may simply be reflected in the strength of memory trace at retrieval - a measure ideally suited to trace strength interrogation using familiarity, as is typically conceptualised within the dual process framework. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Accurate procedure for deriving UTI at a submilliarcsecond accuracy from Greenwich Sidereal Time or from the stellar angle

    Science.gov (United States)

    Capitaine, N.; Gontier, A.-M.

    1993-08-01

    Present observations using modern astrometric techniques are supposed to provide the Earth orientation parameters, and therefore UT1, with an accuracy better than ±1 mas. In practice, UT1 is determined through the intermediary of Greenwich Sidereal Time (GST), using both the conventional relationship between Greenwich Mean Sidereal Time (GMST) and UTl (Aoki et al. 1982) and the so-called "equation of the equinoxes" limited to the first order terms with respect to the nutation quantities. This highly complex relation between sidereal time and UT1 is not accurate at the milliaresecond level which gives rise to spurious terms of milliaresecond amplitude in the derived UTl. A more complete relationship between GST and UT1 has been recommended by Aoki & Kinoshita (1983) and Aoki (1991) taking into account the second order terms in the difference between GST and GM ST, the largest one having an amplitude of 2.64 mas and a 18.6 yr-period. This paper explains how this complete expansion of GST implicitly uses the concept of "nonrotating origin" (NRO) as proposed by Guinot in 1979 and would, therefore, provide a more accurate value of UTl and consequently of the Earth's angular velocity. This paper shows, moreover, that such a procedure would be simplified and conceptually clarified by the explicit use of the NRO as previously proposed (Guinot 1979; Capitaine et al. 1986). The two corresponding options (implicit or explicit use of the NRO) are shown to be equivalent for defining the specific Earth's angle of rotation and then UT1. The of the use of such an accurate procedure which has been proposed in the new IERS standards (McCarthy 1992a) instead of the usual one are estimated for the practical derivation of UT1.

  5. A different interpretation of Einstein's viscosity equation provides accurate representations of the behavior of hydrophilic solutes to high concentrations.

    Science.gov (United States)

    Zavitsas, Andreas A

    2012-08-23

    Viscosities of aqueous solutions of many highly soluble hydrophilic solutes with hydroxyl and amino groups are examined with a focus on improving the concentration range over which Einstein's relationship between solution viscosity and solute volume, V, is applicable accurately. V is the hydrodynamic effective volume of the solute, including any water strongly bound to it and acting as a single entity with it. The widespread practice is to relate the relative viscosity of solute to solvent, η/η(0), to V/V(tot), where V(tot) is the total volume of the solution. For solutions that are not infinitely dilute, it is shown that the volume ratio must be expressed as V/V(0), where V(0) = V(tot) - V. V(0) is the volume of water not bound to the solute, the "free" water solvent. At infinite dilution, V/V(0) = V/V(tot). For the solutions examined, the proportionality constant between the relative viscosity and volume ratio is shown to be 2.9, rather than the 2.5 commonly used. To understand the phenomena relating to viscosity, the hydrodynamic effective volume of water is important. It is estimated to be between 54 and 85 cm(3). With the above interpretations of Einstein's equation, which are consistent with his stated reasoning, the relation between the viscosity and volume ratio remains accurate to much higher concentrations than those attainable with any of the other relations examined that express the volume ratio as V/V(tot).

  6. Accurate screening for synthetic preservatives in beverage using high performance liquid chromatography with time-of-flight mass spectrometry

    International Nuclear Information System (INIS)

    Li Xiuqin; Zhang Feng; Sun Yanyan; Yong Wei; Chu Xiaogang; Fang Yanyan; Zweigenbaum, Jerry

    2008-01-01

    In this study, liquid chromatography time-of-flight mass spectrometry (HPLC/TOF-MS) is applied to qualitation and quantitation of 18 synthetic preservatives in beverage. The identification by HPLC/TOF-MS is accomplished with the accurate mass (the subsequent generated empirical formula) of the protonated molecules [M + H]+ or the deprotonated molecules [M - H]-, along with the accurate mass of their main fragment ions. In order to obtain sufficient sensitivity for quantitation purposes (using the protonated or deprotonated molecule) and additional qualitative mass spectrum information provided by the fragments ions, segment program of fragmentor voltages is designed in positive and negative ion mode, respectively. Accurate mass measurements are highly useful in the complex sample analyses since they allow us to achieve a high degree of specificity, often needed when other interferents are present in the matrix. The mass accuracy typically obtained is routinely better than 3 ppm. The 18 compounds behave linearly in the 0.005-5.0 mg.kg -1 concentration range, with correlation coefficient >0.996. The recoveries at the tested concentrations of 1.0 mg.kg -1 -100 mg.kg -1 are 81-106%, with coefficients of variation -1 , which are far below the required maximum residue level (MRL) for these preservatives in foodstuff. The method is suitable for routine quantitative and qualitative analyses of synthetic preservatives in foodstuff

  7. Biomimetic Approach for Accurate, Real-Time Aerodynamic Coefficients, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Aerodynamic and structural reliability and efficiency depends critically on the ability to accurately assess the aerodynamic loads and moments for each lifting...

  8. An accurate real-time model of maglev planar motor based on compound Simpson numerical integration

    Directory of Open Access Journals (Sweden)

    Baoquan Kou

    2017-05-01

    Full Text Available To realize the high-speed and precise control of the maglev planar motor, a more accurate real-time electromagnetic model, which considers the influence of the coil corners, is proposed in this paper. Three coordinate systems for the stator, mover and corner coil are established. The coil is divided into two segments, the straight coil segment and the corner coil segment, in order to obtain a complete electromagnetic model. When only take the first harmonic of the flux density distribution of a Halbach magnet array into account, the integration method can be carried out towards the two segments according to Lorenz force law. The force and torque analysis formula of the straight coil segment can be derived directly from Newton-Leibniz formula, however, this is not applicable to the corner coil segment. Therefore, Compound Simpson numerical integration method is proposed in this paper to solve the corner segment. With the validation of simulation and experiment, the proposed model has high accuracy and can realize practical application easily.

  9. An accurate real-time model of maglev planar motor based on compound Simpson numerical integration

    Science.gov (United States)

    Kou, Baoquan; Xing, Feng; Zhang, Lu; Zhou, Yiheng; Liu, Jiaqi

    2017-05-01

    To realize the high-speed and precise control of the maglev planar motor, a more accurate real-time electromagnetic model, which considers the influence of the coil corners, is proposed in this paper. Three coordinate systems for the stator, mover and corner coil are established. The coil is divided into two segments, the straight coil segment and the corner coil segment, in order to obtain a complete electromagnetic model. When only take the first harmonic of the flux density distribution of a Halbach magnet array into account, the integration method can be carried out towards the two segments according to Lorenz force law. The force and torque analysis formula of the straight coil segment can be derived directly from Newton-Leibniz formula, however, this is not applicable to the corner coil segment. Therefore, Compound Simpson numerical integration method is proposed in this paper to solve the corner segment. With the validation of simulation and experiment, the proposed model has high accuracy and can realize practical application easily.

  10. FIRST TIME ONLINE LEARNERS’ PERCEPTIONS OF SUPPORT SERVICES PROVIDED

    Directory of Open Access Journals (Sweden)

    Stephanie HUNTE

    2012-04-01

    Full Text Available The number of online continuous education and training initiatives continues to increase in Caribbean Small Island Developing States (SIDS and by extension, the number of adult learners who are unfamiliar with the peculiarities of the online teaching and learning environment. The extent to which these learners can derive maximum benefit from these initiatives depends on the rate at which they can adapt to the new circumstances and, as a result, function effectively in this type of teaching and learning environment. To this end, while supporting learners is recognized as a critical success factor little has been explored or documented specific to the Caribbean-SIDS context. The purpose of this study therefore was to describe the support services provided first time online learners in the context of Caribbean-SIDS and examine what if any benefit learners derived from them through their perceptions of these services. The findings reveal that participants’ overall perception of the support services was high. They also reveal that although participants’ awareness of ongoing support services was variable, their rating of the need for and importance of this type of support was also high. The findings suggest that providing support for first time online learners in the context of Caribbean SIDS positively impacts their performance in the online teaching and learning environment.

  11. On the use of spring baseflow recession for a more accurate parameterization of aquifer transit time distribution functions

    Directory of Open Access Journals (Sweden)

    J. Farlin

    2013-05-01

    Full Text Available Baseflow recession analysis and groundwater dating have up to now developed as two distinct branches of hydrogeology and have been used to solve entirely different problems. We show that by combining two classical models, namely the Boussinesq equation describing spring baseflow recession, and the exponential piston-flow model used in groundwater dating studies, the parameters describing the transit time distribution of an aquifer can be in some cases estimated to a far more accurate degree than with the latter alone. Under the assumption that the aquifer basis is sub-horizontal, the mean transit time of water in the saturated zone can be estimated from spring baseflow recession. This provides an independent estimate of groundwater transit time that can refine those obtained from tritium measurements. The approach is illustrated in a case study predicting atrazine concentration trend in a series of springs draining the fractured-rock aquifer known as the Luxembourg Sandstone. A transport model calibrated on tritium measurements alone predicted different times to trend reversal following the nationwide ban on atrazine in 2005 with different rates of decrease. For some of the springs, the actual time of trend reversal and the rate of change agreed extremely well with the model calibrated using both tritium measurements and the recession of spring discharge during the dry season. The agreement between predicted and observed values was however poorer for the springs displaying the most gentle recessions, possibly indicating a stronger influence of continuous groundwater recharge during the summer months.

  12. Improving Spiking Dynamical Networks: Accurate Delays, Higher-Order Synapses, and Time Cells.

    Science.gov (United States)

    Voelker, Aaron R; Eliasmith, Chris

    2018-03-01

    Researchers building spiking neural networks face the challenge of improving the biological plausibility of their model networks while maintaining the ability to quantitatively characterize network behavior. In this work, we extend the theory behind the neural engineering framework (NEF), a method of building spiking dynamical networks, to permit the use of a broad class of synapse models while maintaining prescribed dynamics up to a given order. This theory improves our understanding of how low-level synaptic properties alter the accuracy of high-level computations in spiking dynamical networks. For completeness, we provide characterizations for both continuous-time (i.e., analog) and discrete-time (i.e., digital) simulations. We demonstrate the utility of these extensions by mapping an optimal delay line onto various spiking dynamical networks using higher-order models of the synapse. We show that these networks nonlinearly encode rolling windows of input history, using a scale invariant representation, with accuracy depending on the frequency content of the input signal. Finally, we reveal that these methods provide a novel explanation of time cell responses during a delay task, which have been observed throughout hippocampus, striatum, and cortex.

  13. Review of current GPS methodologies for producing accurate time series and their error sources

    Science.gov (United States)

    He, Xiaoxing; Montillet, Jean-Philippe; Fernandes, Rui; Bos, Machiel; Yu, Kegen; Hua, Xianghong; Jiang, Weiping

    2017-05-01

    The Global Positioning System (GPS) is an important tool to observe and model geodynamic processes such as plate tectonics and post-glacial rebound. In the last three decades, GPS has seen tremendous advances in the precision of the measurements, which allow researchers to study geophysical signals through a careful analysis of daily time series of GPS receiver coordinates. However, the GPS observations contain errors and the time series can be described as the sum of a real signal and noise. The signal itself can again be divided into station displacements due to geophysical causes and to disturbing factors. Examples of the latter are errors in the realization and stability of the reference frame and corrections due to ionospheric and tropospheric delays and GPS satellite orbit errors. There is an increasing demand on detecting millimeter to sub-millimeter level ground displacement signals in order to further understand regional scale geodetic phenomena hence requiring further improvements in the sensitivity of the GPS solutions. This paper provides a review spanning over 25 years of advances in processing strategies, error mitigation methods and noise modeling for the processing and analysis of GPS daily position time series. The processing of the observations is described step-by-step and mainly with three different strategies in order to explain the weaknesses and strengths of the existing methodologies. In particular, we focus on the choice of the stochastic model in the GPS time series, which directly affects the estimation of the functional model including, for example, tectonic rates, seasonal signals and co-seismic offsets. Moreover, the geodetic community continues to develop computational methods to fully automatize all phases from analysis of GPS time series. This idea is greatly motivated by the large number of GPS receivers installed around the world for diverse applications ranging from surveying small deformations of civil engineering structures (e

  14. Estimating the state of a geophysical system with sparse observations: time delay methods to achieve accurate initial states for prediction

    Science.gov (United States)

    An, Zhe; Rey, Daniel; Ye, Jingxin; Abarbanel, Henry D. I.

    2017-01-01

    The problem of forecasting the behavior of a complex dynamical system through analysis of observational time-series data becomes difficult when the system expresses chaotic behavior and the measurements are sparse, in both space and/or time. Despite the fact that this situation is quite typical across many fields, including numerical weather prediction, the issue of whether the available observations are "sufficient" for generating successful forecasts is still not well understood. An analysis by Whartenby et al. (2013) found that in the context of the nonlinear shallow water equations on a β plane, standard nudging techniques require observing approximately 70 % of the full set of state variables. Here we examine the same system using a method introduced by Rey et al. (2014a), which generalizes standard nudging methods to utilize time delayed measurements. We show that in certain circumstances, it provides a sizable reduction in the number of observations required to construct accurate estimates and high-quality predictions. In particular, we find that this estimate of 70 % can be reduced to about 33 % using time delays, and even further if Lagrangian drifter locations are also used as measurements.

  15. A new approach for accurate mass assignment on a multi-turn time-of-flight mass spectrometer.

    Science.gov (United States)

    Hondo, Toshinobu; Jensen, Kirk R; Aoki, Jun; Toyoda, Michisato

    2017-12-01

    A simple, effective accurate mass assignment procedure for a time-of-flight mass spectrometer is desirable. External mass calibration using a mass calibration standard together with an internal mass reference (lock mass) is a common technique for mass assignment, however, using polynomial fitting can result in mass-dependent errors. By using the multi-turn time-of-flight mass spectrometer infiTOF-UHV, we were able to obtain multiple time-of-flight data from an ion monitored under several different numbers of laps that was then used to calculate a mass calibration equation. We have developed a data acquisition system that simultaneously monitors spectra at several different lap conditions with on-the-fly centroid determination and scan law estimation, which is a function of acceleration voltage, flight path, and instrumental time delay. Less than 0.9 mDa mass errors were observed for assigned mass to charge ratios ( m/z) ranging between 4 and 134 using only 40 Ar + as a reference. It was also observed that estimating the scan law on-the-fly provides excellent mass drift compensation.

  16. Accurate modeling of high frequency microelectromechanical systems (MEMS switches in time- and frequency-domainc

    Directory of Open Access Journals (Sweden)

    F. Coccetti

    2003-01-01

    Full Text Available In this contribution we present an accurate investigation of three different techniques for the modeling of complex planar circuits. The em analysis is performed by means of different electromagnetic full-wave solvers in the timedomain and in the frequency-domain. The first one is the Transmission Line Matrix (TLM method. In the second one the TLM method is combined with the Integral Equation (IE method. The latter is based on the Generalized Transverse Resonance Diffraction (GTRD. In order to test the methods we model different structures and compare the calculated Sparameters to measured results, with good agreement.

  17. A method for accurate detection of genomic microdeletions using real-time quantitative PCR

    Directory of Open Access Journals (Sweden)

    Bassett Anne S

    2005-12-01

    DNA, whilst providing a level of genomic resolution greater than standard cytogenetic assays. The implementation of qPCR detection in clinical laboratories will address the need to replace complex, expensive and time consuming FISH screening to detect genomic microdeletions or duplications of clinical importance.

  18. Robust and Accurate Anomaly Detection in ECG Artifacts Using Time Series Motif Discovery

    Science.gov (United States)

    Sivaraks, Haemwaan

    2015-01-01

    Electrocardiogram (ECG) anomaly detection is an important technique for detecting dissimilar heartbeats which helps identify abnormal ECGs before the diagnosis process. Currently available ECG anomaly detection methods, ranging from academic research to commercial ECG machines, still suffer from a high false alarm rate because these methods are not able to differentiate ECG artifacts from real ECG signal, especially, in ECG artifacts that are similar to ECG signals in terms of shape and/or frequency. The problem leads to high vigilance for physicians and misinterpretation risk for nonspecialists. Therefore, this work proposes a novel anomaly detection technique that is highly robust and accurate in the presence of ECG artifacts which can effectively reduce the false alarm rate. Expert knowledge from cardiologists and motif discovery technique is utilized in our design. In addition, every step of the algorithm conforms to the interpretation of cardiologists. Our method can be utilized to both single-lead ECGs and multilead ECGs. Our experiment results on real ECG datasets are interpreted and evaluated by cardiologists. Our proposed algorithm can mostly achieve 100% of accuracy on detection (AoD), sensitivity, specificity, and positive predictive value with 0% false alarm rate. The results demonstrate that our proposed method is highly accurate and robust to artifacts, compared with competitive anomaly detection methods. PMID:25688284

  19. CoMik : a predictable and cycle-accurately composable real-time microkernel

    NARCIS (Netherlands)

    Nelson, A.T.; Nejad, A.B.; Molnos, A.M.; Koedam, M.L.P.J.; Goossens, K.G.W.

    2014-01-01

    The functionality of embedded systems is ever increasing. This has lead to mixed time-criticality systems, where applications with a variety of real-time requirements co-exist on the same platform and share resources. Due to inter-application interference, verifying the real-time requirements of

  20. Anti-Mullerian hormone is a more accurate predictor of individual time to menopause than mother's age at menopause

    NARCIS (Netherlands)

    Dolleman, M.; Depmann, M.; Eijkemans, M.J.; Heimensem, J.; Broer, S.L.; Stroom, E.M. van der; Laven, J.S.E.; Rooij, I.A.L.M. van; Scheffer, G.J.; Peeters, P.H.M.; Schouw, Y.T. van der; Lambalk, C.B.; Broekmans, F.J.

    2014-01-01

    STUDY QUESTION: In the prediction of time to menopause (TTM), what is the added value of anti-Mullerian hormone (AMH) when mother's age at natural menopause (ANM) is also known? SUMMARY ANSWER: AMH is a more accurate predictor of individual TTM than mother's age at menopause. WHAT IS KNOWN ALREADY:

  1. An Accurate Approximate-Analytical Technique for Solving Time-Fractional Partial Differential Equations

    Directory of Open Access Journals (Sweden)

    M. Bishehniasar

    2017-01-01

    Full Text Available The demand of many scientific areas for the usage of fractional partial differential equations (FPDEs to explain their real-world systems has been broadly identified. The solutions may portray dynamical behaviors of various particles such as chemicals and cells. The desire of obtaining approximate solutions to treat these equations aims to overcome the mathematical complexity of modeling the relevant phenomena in nature. This research proposes a promising approximate-analytical scheme that is an accurate technique for solving a variety of noninteger partial differential equations (PDEs. The proposed strategy is based on approximating the derivative of fractional-order and reducing the problem to the corresponding partial differential equation (PDE. Afterwards, the approximating PDE is solved by using a separation-variables technique. The method can be simply applied to nonhomogeneous problems and is proficient to diminish the span of computational cost as well as achieving an approximate-analytical solution that is in excellent concurrence with the exact solution of the original problem. In addition and to demonstrate the efficiency of the method, it compares with two finite difference methods including a nonstandard finite difference (NSFD method and standard finite difference (SFD technique, which are popular in the literature for solving engineering problems.

  2. A Real-Time Accurate Model and Its Predictive Fuzzy PID Controller for Pumped Storage Unit via Error Compensation

    Directory of Open Access Journals (Sweden)

    Jianzhong Zhou

    2017-12-01

    Full Text Available Model simulation and control of pumped storage unit (PSU are essential to improve the dynamic quality of power station. Only under the premise of the PSU models reflecting the actual transient process, the novel control method can be properly applied in the engineering. The contributions of this paper are that (1 a real-time accurate equivalent circuit model (RAECM of PSU via error compensation is proposed to reconcile the conflict between real-time online simulation and accuracy under various operating conditions, and (2 an adaptive predicted fuzzy PID controller (APFPID based on RAECM is put forward to overcome the instability of conventional control under no-load conditions with low water head. Respectively, all hydraulic factors in pipeline system are fully considered based on equivalent lumped-circuits theorem. The pretreatment, which consists of improved Suter-transformation and BP neural network, and online simulation method featured by two iterative loops are synthetically proposed to improve the solving accuracy of the pump-turbine. Moreover, the modified formulas for compensating error are derived with variable-spatial discretization to improve the accuracy of the real-time simulation further. The implicit RadauIIA method is verified to be more suitable for PSUGS owing to wider stable domain. Then, APFPID controller is constructed based on the integration of fuzzy PID and the model predictive control. Rolling prediction by RAECM is proposed to replace rolling optimization with its computational speed guaranteed. Finally, the simulation and on-site measurements are compared to prove trustworthy of RAECM under various running conditions. Comparative experiments also indicate that APFPID controller outperforms other controllers in most cases, especially low water head conditions. Satisfying results of RAECM have been achieved in engineering and it provides a novel model reference for PSUGS.

  3. Pregnant at work: time for prenatal care providers to act.

    Science.gov (United States)

    Karkowsky, Chavi Eve; Morris, Liz

    2016-09-01

    Fifty years ago, when a woman became pregnant, she was expected to stop working. Today, however, most women who work are the primary, sole, or co-breadwinner for their families, and their earnings during pregnancy are often essential to their families' economic well-being. Medical data about working during pregnancy are sparse but generally show that both low-risk and high-risk women can tolerate work-related duties well, although some work accommodations (eg, providing a chair for sitting, allowing snacks, or modifying the work schedule) may be necessary. However, some employers refuse to accommodate pregnant women who need adjustments. This can result in a woman being forced to make the choice between working without accommodations and losing her income and health insurance or even her job. Prenatal care providers can play an important role by implementing changes in their own practice, shaping public policy, and conducting research to increase protections for pregnant women and to ensure that they receive medically recommended accommodations while continuing to earn income for their growing families. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. An Accurate Method to Determine the Muzzle Leaving Time of Guns

    Directory of Open Access Journals (Sweden)

    H. X. Chao

    2014-11-01

    Full Text Available This paper states the importance of determining the muzzle leaving time of guns with a high degree of accuracy. Two commonly used methods are introduced, which are the high speed photography method and photoelectric transducer method, and the advantage and disadvantage of these two methods are analyzed. Furthermore, a new method to determine the muzzle leaving time of guns based on the combination of high speed photography and synchronized trigger technology is present in this paper, and its principle and uncertainty of measurement are evaluated. The firing experiments shows that the present method has distinguish advantage in accuracy and reliability from other methods.

  5. Towards an Accurate Stress Dependant Time & Frequency Domain VE Response Model for Bituminous Binders

    NARCIS (Netherlands)

    Woldekidan, M.F.; Huurman, M.; Pronk, A.C.

    2010-01-01

    Linear viscoelastic properties of bituminous binders for short loading times are analyzed using dynamic mechanical analysis methods. Dynamic Shear Rheometer (DSR) test with parallel plate (PP) configuration is widely used for this purpose. Due to the complex stress distribution over the

  6. The importance of data collection for timely and accurate risk assessment

    Science.gov (United States)

    Gilsenan, MB

    2017-09-01

    The European Food Safety Authority (EFSA) is responsible for food safety risk assessments at EU level. It provides independent scientific advice on risks associated with the food chain to support EU risk management decisions. Since its establishment, EFSA has amassed a wealth of data to underpin its risk assessments, such as food consumption data, monitoring data and experimental data. Increasing transparency of its risk assessments is a core objective of EFSA. EFSA aims to enhance the quality and transparency of its outputs by giving insofar as possible access to data and methods underpinning its scientific outputs. This paper provides an overview of the role of EFSA, its core data collections and their regulatory framework, as well as data quality and standardisation aspects. Finally, the paper elaborates on EFSA’s 2020 strategy in relation to data, and describes EFSA scientific data warehouse and Knowledge Junction in this regard.

  7. Disambiguating past events: accurate source memory for time and context depends on different retrieval processes

    OpenAIRE

    Persson, Bjorn Martin; Ainge, James Alexander; O'Connor, Akira Robert

    2016-01-01

    Participant payment was provided by the School of Psychology and Neuroscience ResPay scheme. Current animal models of episodic memory are usually based on demonstrating integrated memory for what happened, where it happened, and when an event took place. These models aim to capture the testable features of the definition of human episodic memory which stresses the temporal component of the memory as a unique piece of source information that allows us to disambiguate one memory from another...

  8. Accurate estimation of camera shot noise in the real-time

    Science.gov (United States)

    Cheremkhin, Pavel A.; Evtikhiev, Nikolay N.; Krasnov, Vitaly V.; Rodin, Vladislav G.; Starikov, Rostislav S.

    2017-10-01

    Nowadays digital cameras are essential parts of various technological processes and daily tasks. They are widely used in optics and photonics, astronomy, biology and other various fields of science and technology such as control systems and video-surveillance monitoring. One of the main information limitations of photo- and videocameras are noises of photosensor pixels. Camera's photosensor noise can be divided into random and pattern components. Temporal noise includes random noise component while spatial noise includes pattern noise component. Temporal noise can be divided into signal-dependent shot noise and signal-nondependent dark temporal noise. For measurement of camera noise characteristics, the most widely used methods are standards (for example, EMVA Standard 1288). It allows precise shot and dark temporal noise measurement but difficult in implementation and time-consuming. Earlier we proposed method for measurement of temporal noise of photo- and videocameras. It is based on the automatic segmentation of nonuniform targets (ASNT). Only two frames are sufficient for noise measurement with the modified method. In this paper, we registered frames and estimated shot and dark temporal noises of cameras consistently in the real-time. The modified ASNT method is used. Estimation was performed for the cameras: consumer photocamera Canon EOS 400D (CMOS, 10.1 MP, 12 bit ADC), scientific camera MegaPlus II ES11000 (CCD, 10.7 MP, 12 bit ADC), industrial camera PixeLink PL-B781F (CMOS, 6.6 MP, 10 bit ADC) and video-surveillance camera Watec LCL-902C (CCD, 0.47 MP, external 8 bit ADC). Experimental dependencies of temporal noise on signal value are in good agreement with fitted curves based on a Poisson distribution excluding areas near saturation. Time of registering and processing of frames used for temporal noise estimation was measured. Using standard computer, frames were registered and processed during a fraction of second to several seconds only. Also the

  9. MobileFaceNets: Efficient CNNs for Accurate Real-time Face Verification on Mobile Devices

    OpenAIRE

    Chen, Sheng; Liu, Yang; Gao, Xiang; Han, Zhen

    2018-01-01

    In this paper, we proposed a class of extremely efficient CNN models, MobileFaceNets, which use less than 1 million parameters and are specifically tailored for high-accuracy real-time face verification on mobile and embedded devices. We first make a simple analysis on the weakness of common mobile networks for face verification. The weakness has been well overcome by our specifically designed MobileFaceNets. Under the same experimental conditions, our MobileFaceNets achieve significantly sup...

  10. Accurate Analytical Multiple-Access Performance of Time-Hopping Biorthogonal PPM IR-UWB Systems

    Directory of Open Access Journals (Sweden)

    SVEDEK, T.

    2011-05-01

    Full Text Available In this paper, the characteristic function (CF method is used to derive the symbol error rate (SER expression for time-hopping impulse radio ultra-wideband (TH-IR-UWB systems with a biorthogonal pulse position modulation (BPPM scheme in the presence of a multi-user interference (MUI. The derived expression is validated with the Monte-Carlo simulation and compared with orthogonal PPM. Moreover, the analytical results are compared with the Gaussian approximation (GA of MUI which is shown to be inaccurate for a medium and large signal-to-noise ratio (SNR. It is also shown that the BPPM scheme outperforms the PPM scheme for all SNR. At the end, the influence of different system parameters on the BPPM performance is analyzed.

  11. Real Time Monitoring of Diesel Engine Injector Waveforms for Accurate Fuel Metering and Control

    Directory of Open Access Journals (Sweden)

    Q. R. Farooqi

    2013-01-01

    Full Text Available This paper presents the development, experimentation, and validation of a reliable and robust system to monitor the injector pulse generated by an engine control module (ECM which can easily be calibrated for different engine platforms and then feedback the corresponding fueling quantity to the real-time computer in a closed-loop controller in the loop (CIL bench in order to achieve optimal fueling. This research utilizes field programmable gate arrays (FPGA and direct memory access (DMA transfer capability to achieve high speed data acquisition and delivery. This work is conducted in two stages: the first stage is to study the variability involved in the injected fueling quantity from pulse to pulse, from injector to injector, between real injector stators and inductor load cells, and over different operating conditions. Different thresholds have been used to find out the best start of injection (SOI threshold and the end of injection (EOI threshold that capture the injector “on-time” with best reliability and accuracy. Second stage involves development of a system that interprets the injector pulse into fueling quantity. The system can easily be calibrated for various platforms. Finally, the use of resulting correction table has been observed to capture the fueling quantity with highest accuracy.

  12. Genomic inference accurately predicts the timing and severity of a recent bottleneck in a non-model insect population

    Science.gov (United States)

    McCoy, Rajiv C.; Garud, Nandita R.; Kelley, Joanna L.; Boggs, Carol L.; Petrov, Dmitri A.

    2015-01-01

    The analysis of molecular data from natural populations has allowed researchers to answer diverse ecological questions that were previously intractable. In particular, ecologists are often interested in the demographic history of populations, information that is rarely available from historical records. Methods have been developed to infer demographic parameters from genomic data, but it is not well understood how inferred parameters compare to true population history or depend on aspects of experimental design. Here we present and evaluate a method of SNP discovery using RNA-sequencing and demographic inference using the program δaδi, which uses a diffusion approximation to the allele frequency spectrum to fit demographic models. We test these methods in a population of the checkerspot butterfly Euphydryas gillettii. This population was intentionally introduced to Gothic, Colorado in 1977 and has since experienced extreme fluctuations including bottlenecks of fewer than 25 adults, as documented by nearly annual field surveys. Using RNA-sequencing of eight individuals from Colorado and eight individuals from a native population in Wyoming, we generate the first genomic resources for this system. While demographic inference is commonly used to examine ancient demography, our study demonstrates that our inexpensive, all-in-one approach to marker discovery and genotyping provides sufficient data to accurately infer the timing of a recent bottleneck. This demographic scenario is relevant for many species of conservation concern, few of which have sequenced genomes. Our results are remarkably insensitive to sample size or number of genomic markers, which has important implications for applying this method to other non-model systems. PMID:24237665

  13. Simultaneous transmission of accurate time, stable frequency, data, and sensor system over one fiber with ITU 100 GHz grid

    Science.gov (United States)

    Horvath, Tomas; Munster, Petr; Vojtech, Josef; Velc, Radek; Oujezsky, Vaclav

    2018-01-01

    Optical fiber is the most used medium for current telecommunication networks. Besides data transmissions, special advanced applications like accurate time or stable frequency transmissions are more common, especially in research and education networks. On the other hand, new applications like distributed sensing are in ISP's interest because e.g. such sensing allows new service: protection of fiber infrastructure. Transmission of all applications in a single fiber can be very cost efficient but it is necessary to evaluate possible interaction before real application and deploying the service, especially if standard 100 GHz grid is considered. We performed laboratory measurement of simultaneous transmission of 100 G data based on DP-QPSK modulation format, accurate time, stable frequency and sensing system based on phase sensitive OTDR through two types of optical fibers, G.655 and G.653. These fibers are less common than G.652 fiber but thanks to their slightly higher nonlinear character, there are suitable for simulation of the worst case which can arise in a real network.

  14. STELLAR LOCUS REGRESSION: ACCURATE COLOR CALIBRATION AND THE REAL-TIME DETERMINATION OF GALAXY CLUSTER PHOTOMETRIC REDSHIFTS

    International Nuclear Information System (INIS)

    High, F. William; Stubbs, Christopher W.; Rest, Armin; Stalder, Brian; Challis, Peter

    2009-01-01

    We present stellar locus regression (SLR), a method of directly adjusting the instrumental broadband optical colors of stars to bring them into accord with a universal stellar color-color locus, producing accurately calibrated colors for both stars and galaxies. This is achieved without first establishing individual zero points for each passband, and can be performed in real-time at the telescope. We demonstrate how SLR naturally makes one wholesale correction for differences in instrumental response, for atmospheric transparency, for atmospheric extinction, and for Galactic extinction. We perform an example SLR treatment of Sloan Digital Sky Survey data over a wide range of Galactic dust values and independently recover the direction and magnitude of the canonical Galactic reddening vector with 14-18 mmag rms uncertainties. We then isolate the effect of atmospheric extinction, showing that SLR accounts for this and returns precise colors over a wide range of air mass, with 5-14 mmag rms residuals. We demonstrate that SLR-corrected colors are sufficiently accurate to allow photometric redshift estimates for galaxy clusters (using red sequence galaxies) with an uncertainty σ(z)/(1 + z) = 0.6% per cluster for redshifts 0.09 < z < 0.25. Finally, we identify our objects in the 2MASS all-sky catalog, and produce i-band zero points typically accurate to 18 mmag using only SLR. We offer open-source access to our IDL routines, validated and verified for the implementation of this technique, at http://stellar-locus-regression.googlecode.com.

  15. Assessing reference genes for accurate transcript normalization using quantitative real-time PCR in pearl millet [Pennisetum glaucum (L. R. Br].

    Directory of Open Access Journals (Sweden)

    Prasenjit Saha

    Full Text Available Pearl millet [Pennisetum glaucum (L. R.Br.], a close relative of Panicoideae food crops and bioenergy grasses, offers an ideal system to perform functional genomics studies related to C4 photosynthesis and abiotic stress tolerance. Quantitative real-time reverse transcription polymerase chain reaction (qRT-PCR provides a sensitive platform to conduct such gene expression analyses. However, the lack of suitable internal control reference genes for accurate transcript normalization during qRT-PCR analysis in pearl millet is the major limitation. Here, we conducted a comprehensive assessment of 18 reference genes on 234 samples which included an array of different developmental tissues, hormone treatments and abiotic stress conditions from three genotypes to determine appropriate reference genes for accurate normalization of qRT-PCR data. Analyses of Ct values using Stability Index, BestKeeper, ΔCt, Normfinder, geNorm and RefFinder programs ranked PP2A, TIP41, UBC2, UBQ5 and ACT as the most reliable reference genes for accurate transcript normalization under different experimental conditions. Furthermore, we validated the specificity of these genes for precise quantification of relative gene expression and provided evidence that a combination of the best reference genes are required to obtain optimal expression patterns for both endogeneous genes as well as transgenes in pearl millet.

  16. Third-order-accurate numerical methods for efficient, large time-step solutions of mixed linear and nonlinear problems

    Energy Technology Data Exchange (ETDEWEB)

    Cobb, J.W.

    1995-02-01

    There is an increasing need for more accurate numerical methods for large-scale nonlinear magneto-fluid turbulence calculations. These methods should not only increase the current state of the art in terms of accuracy, but should also continue to optimize other desired properties such as simplicity, minimized computation, minimized memory requirements, and robust stability. This includes the ability to stably solve stiff problems with long time-steps. This work discusses a general methodology for deriving higher-order numerical methods. It also discusses how the selection of various choices can affect the desired properties. The explicit discussion focuses on third-order Runge-Kutta methods, including general solutions and five examples. The study investigates the linear numerical analysis of these methods, including their accuracy, general stability, and stiff stability. Additional appendices discuss linear multistep methods, discuss directions for further work, and exhibit numerical analysis results for some other commonly used lower-order methods.

  17. Growing slower and less accurate: adult age differences in time-accuracy functions for recall and recognition from episodic memory.

    Science.gov (United States)

    Verhaeghen, P; Vandenbroucke, A; Dierckx, V

    1998-01-01

    In 2 experiments, time-accuracy curves were derived for recall and recognition from episodic memory for both young and older adults. In Experiment 1, time-accuracy functions were estimated for free list recall and list recall cued by rhyme words or semantic associations for 13 young and 13 older participants. In Experiment 2, time-accuracy functions were estimated for recognition of word lists with or without distractor items and with or without articulatory suppression for 29 young and 30 older participants. In both studies, age differences were found in the asymptote (i.e., the maximum level of performance attainable) and in the rate of approach toward the asymptote (i.e., the steepness of the curve). These two parameters were only modestly correlated. In Experiment 2, it was found that 89% of the age-related variance in the rate of approach and 62% of the age-related variance in the asymptote was explained by perceptual speed. The data point at the existence of 2 distinct effects of aging on episodic memory, namely a dynamic effect (growing slower) and an asymptotic effect (growing less accurate). The absence of Age x Condition interactions in the age-related parameters in either experiment points at the rather general nature of both aging effects.

  18. Mobile, real-time, and point-of-care augmented reality is robust, accurate, and feasible: a prospective pilot study.

    Science.gov (United States)

    Kenngott, Hannes Götz; Preukschas, Anas Amin; Wagner, Martin; Nickel, Felix; Müller, Michael; Bellemann, Nadine; Stock, Christian; Fangerau, Markus; Radeleff, Boris; Kauczor, Hans-Ulrich; Meinzer, Hans-Peter; Maier-Hein, Lena; Müller-Stich, Beat Peter

    2018-06-01

    Augmented reality (AR) systems are currently being explored by a broad spectrum of industries, mainly for improving point-of-care access to data and images. Especially in surgery and especially for timely decisions in emergency cases, a fast and comprehensive access to images at the patient bedside is mandatory. Currently, imaging data are accessed at a distance from the patient both in time and space, i.e., at a specific workstation. Mobile technology and 3-dimensional (3D) visualization of radiological imaging data promise to overcome these restrictions by making bedside AR feasible. In this project, AR was realized in a surgical setting by fusing a 3D-representation of structures of interest with live camera images on a tablet computer using marker-based registration. The intent of this study was to focus on a thorough evaluation of AR. Feasibility, robustness, and accuracy were thus evaluated consecutively in a phantom model and a porcine model. Additionally feasibility was evaluated in one male volunteer. In the phantom model (n = 10), AR visualization was feasible in 84% of the visualization space with high accuracy (mean reprojection error ± standard deviation (SD): 2.8 ± 2.7 mm; 95th percentile = 6.7 mm). In a porcine model (n = 5), AR visualization was feasible in 79% with high accuracy (mean reprojection error ± SD: 3.5 ± 3.0 mm; 95th percentile = 9.5 mm). Furthermore, AR was successfully used and proved feasible within a male volunteer. Mobile, real-time, and point-of-care AR for clinical purposes proved feasible, robust, and accurate in the phantom, animal, and single-trial human model shown in this study. Consequently, AR following similar implementation proved robust and accurate enough to be evaluated in clinical trials assessing accuracy, robustness in clinical reality, as well as integration into the clinical workflow. If these further studies prove successful, AR might revolutionize data access at patient

  19. A stabilized second-order time accurate finite element formulation for incompressible viscous flow with heat transfer

    International Nuclear Information System (INIS)

    Curi, Marcos Filardy

    2011-01-01

    In view of the problem of global warming and the search for clean energy sources, a worldwide expansion on the use of nuclear energy is foreseen. Thus, the development of science and technology regarding nuclear power plants is essential, in particular in the field of reactor engineering. Fluid mechanics and heat transfer play an important role in the development of nuclear reactors. Computational Fluid Mechanics (CFD) is becoming ever more important in the optimization of cost and safety of the designs. This work presents a stabilized second-order time accurate finite element formulation for incompressible flows with heat transfer. A second order time discretization precedes a spatial discretization using finite elements. The terms that stabilize the finite element method arise naturally from the discretization process, rather than being introduced a priori in the variational formulation. The method was implemented in the program 'ns n ew s olvec2d av 2 M PI' written in FORTRAN90, developed in the Parallel Computing Laboratory at the Institute of Nuclear Engineering (LCP/IEN). Numerical solutions of some representative examples, including free, mixed and forced convection, demonstrate that the proposed stabilized formulation attains very good agreement with experimental and computational results available in the literature. (author)

  20. Determining the best phenological state for accurate mapping of Phragmites australis in wetlands using time series multispectral satellite data

    Science.gov (United States)

    Rupasinghe, P. A.; Markle, C. E.; Marcaccio, J. V.; Chow-Fraser, P.

    2017-12-01

    Phragmites australis (European common reed), is a relatively recent invader of wetlands and beaches in Ontario. It can establish large homogenous stands within wetlands and disperse widely throughout the landscape by wind and vehicular traffic. A first step in managing this invasive species includes accurate mapping and quantification of its distribution. This is challenging because Phragimtes is distributed in a large spatial extent, which makes the mapping more costly and time consuming. Here, we used freely available multispectral satellite images taken monthly (cloud free images as available) for the calendar year to determine the optimum phenological state of Phragmites that would allow it to be accurately identified using remote sensing data. We analyzed time series, Landsat-8 OLI and Sentinel-2 images for Big Creek Wildlife Area, ON using image classification (Support Vector Machines), Normalized Difference Vegetation Index (NDVI) and Normalized Difference Water Index (NDWI). We used field sampling data and high resolution image collected using Unmanned Aerial Vehicle (UAV; 8 cm spatial resolution) as training data and for the validation of the classified images. The accuracy for all land cover classes and for Phragmites alone were low at both the start and end of the calendar year, but reached overall accuracy >85% by mid to late summer. The highest classification accuracies for Landsat-8 OLI were associated with late July and early August imagery. We observed similar trends using the Sentinel-2 images, with higher overall accuracy for all land cover classes and for Phragmites alone from late July to late September. During this period, we found the greatest difference between Phragmites and Typha, commonly confused classes, with respect to near-infrared and shortwave infrared reflectance. Therefore, the unique spectral signature of Phragmites can be attributed to both the level of greenness and factors related to water content in the leaves during late

  1. Perception of CPR quality: Influence of CPR feedback, Just-in-Time CPR training and provider role.

    Science.gov (United States)

    Cheng, Adam; Overly, Frank; Kessler, David; Nadkarni, Vinay M; Lin, Yiqun; Doan, Quynh; Duff, Jonathan P; Tofil, Nancy M; Bhanji, Farhan; Adler, Mark; Charnovich, Alex; Hunt, Elizabeth A; Brown, Linda L

    2015-02-01

    Many healthcare providers rely on visual perception to guide cardiopulmonary resuscitation (CPR), but little is known about the accuracy of provider perceptions of CPR quality. We aimed to describe the difference between perceived versus measured CPR quality, and to determine the impact of provider role, real-time visual CPR feedback and Just-in-Time (JIT) CPR training on provider perceptions. We conducted secondary analyses of data collected from a prospective, multicenter, randomized trial of 324 healthcare providers who participated in a simulated cardiac arrest scenario between July 2012 and April 2014. Participants were randomized to one of four permutations of: JIT CPR training and real-time visual CPR feedback. We calculated the difference between perceived and measured quality of CPR and reported the proportion of subjects accurately estimating the quality of CPR within each study arm. Participants overestimated achieving adequate chest compression depth (mean difference range: 16.1-60.6%) and rate (range: 0.2-51%), and underestimated chest compression fraction (0.2-2.9%) across all arms. Compared to no intervention, the use of real-time feedback and JIT CPR training (alone or in combination) improved perception of depth (pCPR quality was poor for chest compression depth (0-13%), rate (5-46%) and chest compression fraction (60-63%). Perception of depth is more accurate in CPR providers versus team leaders (27.8% vs. 7.4%; p=0.043) when using real-time feedback. Healthcare providers' visual perception of CPR quality is poor. Perceptions of CPR depth are improved by using real-time visual feedback and with prior JIT CPR training. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  2. An accurate and rapid continuous wavelet dynamic time warping algorithm for unbalanced global mapping in nanopore sequencing

    KAUST Repository

    Han, Renmin

    2017-12-24

    Long-reads, point-of-care, and PCR-free are the promises brought by nanopore sequencing. Among various steps in nanopore data analysis, the global mapping between the raw electrical current signal sequence and the expected signal sequence from the pore model serves as the key building block to base calling, reads mapping, variant identification, and methylation detection. However, the ultra-long reads of nanopore sequencing and an order of magnitude difference in the sampling speeds of the two sequences make the classical dynamic time warping (DTW) and its variants infeasible to solve the problem. Here, we propose a novel multi-level DTW algorithm, cwDTW, based on continuous wavelet transforms with different scales of the two signal sequences. Our algorithm starts from low-resolution wavelet transforms of the two sequences, such that the transformed sequences are short and have similar sampling rates. Then the peaks and nadirs of the transformed sequences are extracted to form feature sequences with similar lengths, which can be easily mapped by the original DTW. Our algorithm then recursively projects the warping path from a lower-resolution level to a higher-resolution one by building a context-dependent boundary and enabling a constrained search for the warping path in the latter. Comprehensive experiments on two real nanopore datasets on human and on Pandoraea pnomenusa, as well as two benchmark datasets from previous studies, demonstrate the efficiency and effectiveness of the proposed algorithm. In particular, cwDTW can almost always generate warping paths that are very close to the original DTW, which are remarkably more accurate than the state-of-the-art methods including FastDTW and PrunedDTW. Meanwhile, on the real nanopore datasets, cwDTW is about 440 times faster than FastDTW and 3000 times faster than the original DTW. Our program is available at https://github.com/realbigws/cwDTW.

  3. Accurate, Fast and Cost-Effective Diagnostic Test for Monosomy 1p36 Using Real-Time Quantitative PCR

    Directory of Open Access Journals (Sweden)

    Pricila da Silva Cunha

    2014-01-01

    Full Text Available Monosomy 1p36 is considered the most common subtelomeric deletion syndrome in humans and it accounts for 0.5–0.7% of all the cases of idiopathic intellectual disability. The molecular diagnosis is often made by microarray-based comparative genomic hybridization (aCGH, which has the drawback of being a high-cost technique. However, patients with classic monosomy 1p36 share some typical clinical characteristics that, together with its common prevalence, justify the development of a less expensive, targeted diagnostic method. In this study, we developed a simple, rapid, and inexpensive real-time quantitative PCR (qPCR assay for targeted diagnosis of monosomy 1p36, easily accessible for low-budget laboratories in developing countries. For this, we have chosen two target genes which are deleted in the majority of patients with monosomy 1p36: PRKCZ and SKI. In total, 39 patients previously diagnosed with monosomy 1p36 by aCGH, fluorescent in situ hybridization (FISH, and/or multiplex ligation-dependent probe amplification (MLPA all tested positive on our qPCR assay. By simultaneously using these two genes we have been able to detect 1p36 deletions with 100% sensitivity and 100% specificity. We conclude that qPCR of PRKCZ and SKI is a fast and accurate diagnostic test for monosomy 1p36, costing less than 10 US dollars in reagent costs.

  4. AN ACCURATE ORBITAL INTEGRATOR FOR THE RESTRICTED THREE-BODY PROBLEM AS A SPECIAL CASE OF THE DISCRETE-TIME GENERAL THREE-BODY PROBLEM

    International Nuclear Information System (INIS)

    Minesaki, Yukitaka

    2013-01-01

    For the restricted three-body problem, we propose an accurate orbital integration scheme that retains all conserved quantities of the two-body problem with two primaries and approximately preserves the Jacobi integral. The scheme is obtained by taking the limit as mass approaches zero in the discrete-time general three-body problem. For a long time interval, the proposed scheme precisely reproduces various periodic orbits that cannot be accurately computed by other generic integrators

  5. The clock face guide to peroneal intraneural ganglia: critical ''times'' and sites for accurate diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Spinner, Robert J. [Mayo Clinic, Department of Neurologic Surgery, Rochester, MN (United States); Mayo Clinic, Department of Orthopedics, Rochester, MN (United States); Mayo Clinic, Department of Anatomy, Rochester, MN (United States); Luthra, Gauri [University College Cork, National University of Ireland, Cork (Ireland); Desy, Nicholas M. [McGill University School of Medicine, Department of Orthopedics, Montreal, Quebec (Canada); Anderson, Meredith L. [Mayo Clinic, Department of Radiology, Rochester, MN (United States); Amrami, Kimberly K. [Mayo Clinic, Department of Neurologic Surgery, Rochester, MN (United States); Mayo Clinic, Department of Radiology, Rochester, MN (United States)

    2008-12-15

    The aim of this study is to exploit the normal nature of peroneal nerve anatomy to identify constant magnetic resonance imaging (MRI) patterns in peroneal intraneural ganglia. This study is designed as a retrospective clinical study. MR images of 25 patients with peroneal intraneural ganglia were analyzed and were compared to those of 25 patients with extraneural ganglia and 25 individuals with normal knees. All specimens were interpreted as left-sided. Using conventional axial images, the position of the common peroneal nerve and either intraneural or extraneural cyst was determined relative to the proximal fibula and the superior tibiofibular joint using a symbolic clock face. In all patients, the common peroneal nerve could be seen between the 4 and 5 o'clock position at the mid-portion of the fibular head. In patients with intraneural ganglia, a single axial image could reproducibly and reliably demonstrate both cyst within the common peroneal nerve at the mid-portion of the fibular head (signet ring sign) between 4 and 5 o'clock and within the articular branch at the superior tibiofibular joint connection (tail sign) between 11 and 12 o'clock; in addition, cyst within the transverse limb of the articular branch (transverse limb sign) was seen at the mid-portion of the fibular neck between the 12 and 2 o'clock positions on serial images. Extraneural ganglia typically arose from more superior joint connections with the epicenter of the cyst varying around the entire clock face without a consistent pattern. There was no significant difference between the visual and template assessment of clock face position for all three groups (intraneural, extraneural, and controls). We believe that the normal anatomic and pathologic relationships of the common peroneal nerve in the vicinity of the fibular neck/head region can be established readily and reliably on single axial images. This technique can provide radiologists and surgeons with rapid and

  6. EVALUATING CONTINUOUS-TIME SLAM USING A PREDEFINED TRAJECTORY PROVIDED BY A ROBOTIC ARM

    Directory of Open Access Journals (Sweden)

    B. Koch

    2017-09-01

    Full Text Available Recently published approaches to SLAM algorithms process laser sensor measurements and output a map as a point cloud of the environment. Often the actual precision of the map remains unclear, since SLAMalgorithms apply local improvements to the resulting map. Unfortunately, it is not trivial to compare the performance of SLAMalgorithms objectively, especially without an accurate ground truth. This paper presents a novel benchmarking technique that allows to compare a precise map generated with an accurate ground truth trajectory to a map with a manipulated trajectory which was distorted by different forms of noise. The accurate ground truth is acquired by mounting a laser scanner on an industrial robotic arm. The robotic arm is moved on a predefined path while the position and orientation of the end-effector tool are monitored. During this process the 2D profile measurements of the laser scanner are recorded in six degrees of freedom and afterwards used to generate a precise point cloud of the test environment. For benchmarking, an offline continuous-time SLAM algorithm is subsequently applied to remove the inserted distortions. Finally, it is shown that the manipulated point cloud is reversible to its previous state and is slightly improved compared to the original version, since small errors that came into account by imprecise assumptions, sensor noise and calibration errors are removed as well.

  7. Evaluating Continuous-Time Slam Using a Predefined Trajectory Provided by a Robotic Arm

    Science.gov (United States)

    Koch, B.; Leblebici, R.; Martell, A.; Jörissen, S.; Schilling, K.; Nüchter, A.

    2017-09-01

    Recently published approaches to SLAM algorithms process laser sensor measurements and output a map as a point cloud of the environment. Often the actual precision of the map remains unclear, since SLAMalgorithms apply local improvements to the resulting map. Unfortunately, it is not trivial to compare the performance of SLAMalgorithms objectively, especially without an accurate ground truth. This paper presents a novel benchmarking technique that allows to compare a precise map generated with an accurate ground truth trajectory to a map with a manipulated trajectory which was distorted by different forms of noise. The accurate ground truth is acquired by mounting a laser scanner on an industrial robotic arm. The robotic arm is moved on a predefined path while the position and orientation of the end-effector tool are monitored. During this process the 2D profile measurements of the laser scanner are recorded in six degrees of freedom and afterwards used to generate a precise point cloud of the test environment. For benchmarking, an offline continuous-time SLAM algorithm is subsequently applied to remove the inserted distortions. Finally, it is shown that the manipulated point cloud is reversible to its previous state and is slightly improved compared to the original version, since small errors that came into account by imprecise assumptions, sensor noise and calibration errors are removed as well.

  8. Laser-assisted indocyanine green dye angiography accurately predicts the split-thickness graft timing of integra artificial dermis.

    Science.gov (United States)

    Fourman, Mitchell S; Phillips, Brett T; Fritz, Jason R; Conkling, Nicole; McClain, Steve A; Simon, Marcia; Dagum, Alexander B

    2014-08-01

    angiography may provide valuable information as to graft integrity and split-thickness skin graft timing at late time points. Range of LDI seems to be insufficient for split-thickness graft timing or late time point accuracy. Future exploration of ICG angiography potential will involve tracking Integra graft delay in porcine models.

  9. Time providing care outside visits in a home-based primary care program.

    Science.gov (United States)

    Pedowitz, Elizabeth J; Ornstein, Katherine A; Farber, Jeffrey; DeCherrie, Linda V

    2014-06-01

    To assess how much time physicians in a large home-based primary care (HBPC) program spend providing care outside of home visits. Unreimbursed time and patient and provider-related factors that may contribute to that time were considered. Mount Sinai Visiting Doctors (MSVD) providers filled out research forms for every interaction involving care provision outside of home visits. Data collected included length of interaction, mode, nature, and with whom the interaction was for 3 weeks. MSVD, an academic home-visit program in Manhattan, New York. All primary care physicians (PCPs) in MSVD (n = 14) agreed to participate. Time data were analyzed using a comprehensive estimate and conservative estimates to quantify unbillable time. Data on 1,151 interactions for 537 patients were collected. An average 8.2 h/wk was spent providing nonhome visit care for a full-time provider. Using the most conservative estimates, 3.6 h/wk was estimated to be unreimbursed per full-time provider. No significant differences in interaction times were found between patients with and without dementia, new and established patients, and primary-panel and covered patients. Home-based primary care providers spend substantial time providing care outside home visits, much of which goes unrecognized in the current reimbursement system. These findings may help guide practice development and creation of new payment systems for HBPC and similar models of care. © 2014, Copyright the Authors Journal compilation © 2014, The American Geriatrics Society.

  10. A gp41-based heteroduplex mobility assay provides rapid and accurate assessment of intrasubtype epidemiological linkage in HIV type 1 heterosexual transmission Pairs.

    Science.gov (United States)

    Manigart, Olivier; Boeras, Debrah I; Karita, Etienne; Hawkins, Paulina A; Vwalika, Cheswa; Makombe, Nathan; Mulenga, Joseph; Derdeyn, Cynthia A; Allen, Susan; Hunter, Eric

    2012-12-01

    A critical step in HIV-1 transmission studies is the rapid and accurate identification of epidemiologically linked transmission pairs. To date, this has been accomplished by comparison of polymerase chain reaction (PCR)-amplified nucleotide sequences from potential transmission pairs, which can be cost-prohibitive for use in resource-limited settings. Here we describe a rapid, cost-effective approach to determine transmission linkage based on the heteroduplex mobility assay (HMA), and validate this approach by comparison to nucleotide sequencing. A total of 102 HIV-1-infected Zambian and Rwandan couples, with known linkage, were analyzed by gp41-HMA. A 400-base pair fragment within the envelope gp41 region of the HIV proviral genome was PCR amplified and HMA was applied to both partners' amplicons separately (autologous) and as a mixture (heterologous). If the diversity between gp41 sequences was low (<5%), a homoduplex was observed upon gel electrophoresis and the transmission was characterized as having occurred between partners (linked). If a new heteroduplex formed, within the heterologous migration, the transmission was determined to be unlinked. Initial blind validation of gp-41 HMA demonstrated 90% concordance between HMA and sequencing with 100% concordance in the case of linked transmissions. Following validation, 25 newly infected partners in Kigali and 12 in Lusaka were evaluated prospectively using both HMA and nucleotide sequences. Concordant results were obtained in all but one case (97.3%). The gp41-HMA technique is a reliable and feasible tool to detect linked transmissions in the field. All identified unlinked results should be confirmed by sequence analyses.

  11. Real-time Accurate Surface Reconstruction Pipeline for Vision Guided Planetary Exploration Using Unmanned Ground and Aerial Vehicles

    Science.gov (United States)

    Almeida, Eduardo DeBrito

    2012-01-01

    This report discusses work completed over the summer at the Jet Propulsion Laboratory (JPL), California Institute of Technology. A system is presented to guide ground or aerial unmanned robots using computer vision. The system performs accurate camera calibration, camera pose refinement and surface extraction from images collected by a camera mounted on the vehicle. The application motivating the research is planetary exploration and the vehicles are typically rovers or unmanned aerial vehicles. The information extracted from imagery is used primarily for navigation, as robot location is the same as the camera location and the surfaces represent the terrain that rovers traverse. The processed information must be very accurate and acquired very fast in order to be useful in practice. The main challenge being addressed by this project is to achieve high estimation accuracy and high computation speed simultaneously, a difficult task due to many technical reasons.

  12. On the Accurate Determination of Shock Wave Time-Pressure Profile in the Experimental Models of Blast-Induced Neurotrauma

    Directory of Open Access Journals (Sweden)

    Maciej Skotak

    2018-02-01

    Full Text Available Measurement issues leading to the acquisition of artifact-free shock wave pressure-time profiles are discussed. We address the importance of in-house sensor calibration and data acquisition sampling rate. Sensor calibration takes into account possible differences between calibration methodology in a manufacturing facility, and those used in the specific laboratory. We found in-house calibration factors of brand new sensors differ by less than 10% from their manufacturer supplied data. Larger differences were noticeable for sensors that have been used for hundreds of experiments and were as high as 30% for sensors close to the end of their useful lifetime. These observations were despite the fact that typical overpressures in our experiments do not exceed 50 psi for sensors that are rated at 1,000 psi maximum pressure. We demonstrate that sampling rate of 1,000 kHz is necessary to capture the correct rise time values, but there were no statistically significant differences between peak overpressure and impulse values for low-intensity shock waves (Mach number <2 at lower rates. We discuss two sources of experimental errors originating from mechanical vibration and electromagnetic interference on the quality of a waveform recorded using state-of-the-art high-frequency pressure sensors. The implementation of preventive measures, pressure acquisition artifacts, and data interpretation with examples, are provided in this paper that will help the community at large to avoid these mistakes. In order to facilitate inter-laboratory data comparison, common reporting standards should be developed by the blast TBI research community. We noticed the majority of published literature on the subject limits reporting to peak overpressure; with much less attention directed toward other important parameters, i.e., duration, impulse, and dynamic pressure. These parameters should be included as a mandatory requirement in publications so the results can be properly

  13. Providing Survivable Real-Time Communication Service for Distributed Mission Critical Systems

    National Research Council Canada - National Science Library

    Zhao, Wei; Bettati, Riccardo; Vaidya, Nitin

    2005-01-01

    This document is the final report for Providing Survivable Real-Time Communication Service for Distributed Mission Critical Systems, a Texas A AND M project funded through the DARPA Fault Tolerant Networks Program...

  14. Accurate market price formation model with both supply-demand and trend-following for global food prices providing policy recommendations.

    Science.gov (United States)

    Lagi, Marco; Bar-Yam, Yavni; Bertrand, Karla Z; Bar-Yam, Yaneer

    2015-11-10

    Recent increases in basic food prices are severely affecting vulnerable populations worldwide. Proposed causes such as shortages of grain due to adverse weather, increasing meat consumption in China and India, conversion of corn to ethanol in the United States, and investor speculation on commodity markets lead to widely differing implications for policy. A lack of clarity about which factors are responsible reinforces policy inaction. Here, for the first time to our knowledge, we construct a dynamic model that quantitatively agrees with food prices. The results show that the dominant causes of price increases are investor speculation and ethanol conversion. Models that just treat supply and demand are not consistent with the actual price dynamics. The two sharp peaks in 2007/2008 and 2010/2011 are specifically due to investor speculation, whereas an underlying upward trend is due to increasing demand from ethanol conversion. The model includes investor trend following as well as shifting between commodities, equities, and bonds to take advantage of increased expected returns. Claims that speculators cannot influence grain prices are shown to be invalid by direct analysis of price-setting practices of granaries. Both causes of price increase, speculative investment and ethanol conversion, are promoted by recent regulatory changes-deregulation of the commodity markets, and policies promoting the conversion of corn to ethanol. Rapid action is needed to reduce the impacts of the price increases on global hunger.

  15. Screening and confirmation criteria for hormone residue analysis using liquid chromatography accurate mass time-of-flight, Fourier transform ion cyclotron resonance and orbitrap mass spectrometry techniques

    NARCIS (Netherlands)

    Nielen, M.W.F.; Engelen, M.C. van; Zuiderent, R.; Ramaker, R.

    2007-01-01

    An emerging trend is recognised in hormone and veterinary drug residue analysis from liquid chromatography tandem mass spectrometry (LC/MS/MS) based screening and confirmation towards accurate mass alternatives such as LC coupled with time-of-flight (TOF), Fourier transform ion cyclotron resonance

  16. Incorporation of exact boundary conditions into a discontinuous galerkin finite element method for accurately solving 2d time-dependent maxwell equations

    KAUST Repository

    Sirenko, Kostyantyn; Liu, Meilin; Bagci, Hakan

    2013-01-01

    A scheme that discretizes exact absorbing boundary conditions (EACs) to incorporate them into a time-domain discontinuous Galerkin finite element method (TD-DG-FEM) is described. The proposed TD-DG-FEM with EACs is used for accurately characterizing

  17. 77 FR 1708 - Cooperative Research and Development Agreement: Technology To Provide Wireless Precise Time...

    Science.gov (United States)

    2012-01-11

    ... Systems (GPS) as a means of providing precise time. The alternative under consideration is a wireless... authorized by the Federal Technology Transfer Act of 1986 (Pub. L. 99- 502, codified at 15 U.S.C. 3710(a)). A..., and document at least one alternative to Global Positioning Systems (GPS) as a means of providing...

  18. Accurate Ground-State Energies of Solids and Molecules from Time-Dependent Density-Functional Theory

    DEFF Research Database (Denmark)

    Olsen, Thomas; Thygesen, Kristian Sommer

    2014-01-01

    We demonstrate that ground-state energies approaching chemical accuracy can be obtained by combining the adiabatic-connection fluctuation-dissipation theorem with time-dependent densityfunctional theory. The key ingredient is a renormalization scheme, which eliminates the divergence...

  19. Real-Time and Accurate Indoor Localization with Fusion Model of Wi-Fi Fingerprint and Motion Particle Filter

    Directory of Open Access Journals (Sweden)

    Xinlong Jiang

    2015-01-01

    Full Text Available As the development of Indoor Location Based Service (Indoor LBS, a timely localization and smooth tracking with high accuracy are desperately needed. Unfortunately, any single method cannot meet the requirement of both high accuracy and real-time ability at the same time. In this paper, we propose a fusion location framework with Particle Filter using Wi-Fi signals and motion sensors. In this framework, we use Extreme Learning Machine (ELM regression algorithm to predict position based on motion sensors and use Wi-Fi fingerprint location result to solve the error accumulation of motion sensors based location occasionally with Particle Filter. The experiments show that the trajectory is smoother as the real one than the traditional Wi-Fi fingerprint method.

  20. Accurate characterization of 3D diffraction gratings using time domain discontinuous Galerkin method with exact absorbing boundary conditions

    KAUST Repository

    Sirenko, Kostyantyn

    2013-07-01

    Exact absorbing and periodic boundary conditions allow to truncate grating problems\\' infinite physical domains without introducing any errors. This work presents exact absorbing boundary conditions for 3D diffraction gratings and describes their discretization within a high-order time-domain discontinuous Galerkin finite element method (TD-DG-FEM). The error introduced by the boundary condition discretization matches that of the TD-DG-FEM; this results in an optimal solver in terms of accuracy and computation time. Numerical results demonstrate the superiority of this solver over TD-DG-FEM with perfectly matched layers (PML)-based domain truncation. © 2013 IEEE.

  1. A Robust Motion Artifact Detection Algorithm for Accurate Detection of Heart Rates From Photoplethysmographic Signals Using Time-Frequency Spectral Features.

    Science.gov (United States)

    Dao, Duy; Salehizadeh, S M A; Noh, Yeonsik; Chong, Jo Woon; Cho, Chae Ho; McManus, Dave; Darling, Chad E; Mendelson, Yitzhak; Chon, Ki H

    2017-09-01

    recently developed in our laboratory. The proposed TifMA algorithm consistently provided higher detection rates than the other three methods, with accuracies greater than 95% for all data. Moreover, our algorithm was able to pinpoint the start and end times of the MNA with an error of less than 1 s in duration, whereas the next-best algorithm had a detection error of more than 2.2 s. The final, most challenging, dataset was collected to verify the performance of the algorithm in discriminating between corrupted data that were usable for accurate HR estimations and data that were nonusable. It was found that on average 48% of the data segments were found to have MNA, and of these, 38% could be used to provide reliable HR estimation.

  2. Identification and evaluation of new reference genes in Gossypium hirsutum for accurate normalization of real-time quantitative RT-PCR data

    Directory of Open Access Journals (Sweden)

    Alves-Ferreira Marcio

    2010-03-01

    Full Text Available Abstract Background Normalizing through reference genes, or housekeeping genes, can make more accurate and reliable results from reverse transcription real-time quantitative polymerase chain reaction (qPCR. Recent studies have shown that no single housekeeping gene is universal for all experiments. Thus, suitable reference genes should be the first step of any qPCR analysis. Only a few studies on the identification of housekeeping gene have been carried on plants. Therefore qPCR studies on important crops such as cotton has been hampered by the lack of suitable reference genes. Results By the use of two distinct algorithms, implemented by geNorm and NormFinder, we have assessed the gene expression of nine candidate reference genes in cotton: GhACT4, GhEF1α5, GhFBX6, GhPP2A1, GhMZA, GhPTB, GhGAPC2, GhβTUB3 and GhUBQ14. The candidate reference genes were evaluated in 23 experimental samples consisting of six distinct plant organs, eight stages of flower development, four stages of fruit development and in flower verticils. The expression of GhPP2A1 and GhUBQ14 genes were the most stable across all samples and also when distinct plants organs are examined. GhACT4 and GhUBQ14 present more stable expression during flower development, GhACT4 and GhFBX6 in the floral verticils and GhMZA and GhPTB during fruit development. Our analysis provided the most suitable combination of reference genes for each experimental set tested as internal control for reliable qPCR data normalization. In addition, to illustrate the use of cotton reference genes we checked the expression of two cotton MADS-box genes in distinct plant and floral organs and also during flower development. Conclusion We have tested the expression stabilities of nine candidate genes in a set of 23 tissue samples from cotton plants divided into five different experimental sets. As a result of this evaluation, we recommend the use of GhUBQ14 and GhPP2A1 housekeeping genes as superior references

  3. Identification and evaluation of new reference genes in Gossypium hirsutum for accurate normalization of real-time quantitative RT-PCR data.

    Science.gov (United States)

    Artico, Sinara; Nardeli, Sarah M; Brilhante, Osmundo; Grossi-de-Sa, Maria Fátima; Alves-Ferreira, Marcio

    2010-03-21

    Normalizing through reference genes, or housekeeping genes, can make more accurate and reliable results from reverse transcription real-time quantitative polymerase chain reaction (qPCR). Recent studies have shown that no single housekeeping gene is universal for all experiments. Thus, suitable reference genes should be the first step of any qPCR analysis. Only a few studies on the identification of housekeeping gene have been carried on plants. Therefore qPCR studies on important crops such as cotton has been hampered by the lack of suitable reference genes. By the use of two distinct algorithms, implemented by geNorm and NormFinder, we have assessed the gene expression of nine candidate reference genes in cotton: GhACT4, GhEF1alpha5, GhFBX6, GhPP2A1, GhMZA, GhPTB, GhGAPC2, GhbetaTUB3 and GhUBQ14. The candidate reference genes were evaluated in 23 experimental samples consisting of six distinct plant organs, eight stages of flower development, four stages of fruit development and in flower verticils. The expression of GhPP2A1 and GhUBQ14 genes were the most stable across all samples and also when distinct plants organs are examined. GhACT4 and GhUBQ14 present more stable expression during flower development, GhACT4 and GhFBX6 in the floral verticils and GhMZA and GhPTB during fruit development. Our analysis provided the most suitable combination of reference genes for each experimental set tested as internal control for reliable qPCR data normalization. In addition, to illustrate the use of cotton reference genes we checked the expression of two cotton MADS-box genes in distinct plant and floral organs and also during flower development. We have tested the expression stabilities of nine candidate genes in a set of 23 tissue samples from cotton plants divided into five different experimental sets. As a result of this evaluation, we recommend the use of GhUBQ14 and GhPP2A1 housekeeping genes as superior references for normalization of gene expression measures in

  4. Nuclear magnetic resonance provides a quantitative description of protein conformational flexibility on physiologically important time scales.

    Science.gov (United States)

    Salmon, Loïc; Bouvignies, Guillaume; Markwick, Phineus; Blackledge, Martin

    2011-04-12

    A complete description of biomolecular activity requires an understanding of the nature and the role of protein conformational dynamics. In recent years, novel nuclear magnetic resonance-based techniques that provide hitherto inaccessible detail concerning biomolecular motions occurring on physiologically important time scales have emerged. Residual dipolar couplings (RDCs) provide precise information about time- and ensemble-averaged structural and dynamic processes with correlation times up to the millisecond and thereby encode key information for understanding biological activity. In this review, we present the application of two very different approaches to the quantitative description of protein motion using RDCs. The first is purely analytical, describing backbone dynamics in terms of diffusive motions of each peptide plane, using extensive statistical analysis to validate the proposed dynamic modes. The second is based on restraint-free accelerated molecular dynamics simulation, providing statistically sampled free energy-weighted ensembles that describe conformational fluctuations occurring on time scales from pico- to milliseconds, at atomic resolution. Remarkably, the results from these two approaches converge closely in terms of distribution and absolute amplitude of motions, suggesting that this kind of combination of analytical and numerical models is now capable of providing a unified description of protein conformational dynamics in solution.

  5. 78 FR 38949 - Computer Security Incident Coordination (CSIC): Providing Timely Cyber Incident Response

    Science.gov (United States)

    2013-06-28

    ... exposed to various forms of cyber attack. In some cases, attacks can be thwarted through the use of...-3383-01] Computer Security Incident Coordination (CSIC): Providing Timely Cyber Incident Response... systems will be successfully attacked. When a successful attack occurs, the job of a Computer Security...

  6. High-Throughput Accurate Single-Cell Screening of Euglena gracilis with Fluorescence-Assisted Optofluidic Time-Stretch Microscopy.

    Directory of Open Access Journals (Sweden)

    Baoshan Guo

    Full Text Available The development of reliable, sustainable, and economical sources of alternative fuels is an important, but challenging goal for the world. As an alternative to liquid fossil fuels, algal biofuel is expected to play a key role in alleviating global warming since algae absorb atmospheric CO2 via photosynthesis. Among various algae for fuel production, Euglena gracilis is an attractive microalgal species as it is known to produce wax ester (good for biodiesel and aviation fuel within lipid droplets. To date, while there exist many techniques for inducing microalgal cells to produce and accumulate lipid with high efficiency, few analytical methods are available for characterizing a population of such lipid-accumulated microalgae including E. gracilis with high throughout, high accuracy, and single-cell resolution simultaneously. Here we demonstrate high-throughput, high-accuracy, single-cell screening of E. gracilis with fluorescence-assisted optofluidic time-stretch microscopy-a method that combines the strengths of microfluidic cell focusing, optical time-stretch microscopy, and fluorescence detection used in conventional flow cytometry. Specifically, our fluorescence-assisted optofluidic time-stretch microscope consists of an optical time-stretch microscope and a fluorescence analyzer on top of a hydrodynamically focusing microfluidic device and can detect fluorescence from every E. gracilis cell in a population and simultaneously obtain its image with a high throughput of 10,000 cells/s. With the multi-dimensional information acquired by the system, we classify nitrogen-sufficient (ordinary and nitrogen-deficient (lipid-accumulated E. gracilis cells with a low false positive rate of 1.0%. This method holds promise for evaluating cultivation techniques and selective breeding for microalgae-based biofuel production.

  7. Accurate and Integrated Localization System for Indoor Environments Based on IEEE 802.11 Round-Trip Time Measurements

    Directory of Open Access Journals (Sweden)

    Alfonso Bahillo

    2010-01-01

    Full Text Available The presence of (Non line of Sight NLOS propagation paths has been considered the main drawback for localization schemes to estimate the position of a (Mobile User MU in an indoor environment. This paper presents a comprehensive wireless localization system based on (Round-Trip Time RTT measurements in an unmodified IEEE 802.11 wireless network. It overcomes the NLOS impairment by implementing the (Prior NLOS Measurements Correction PNMC technique. At first, the RTT measurements are performed with a novel electronic circuit avoiding the need for time synchronization between wireless nodes. At second, the distance between the MU and each reference device is estimated by using a simple linear regression function that best relates the RTT to the distance in (Line of Sight LOS. Assuming that LOS in an indoor environment is a simplification of reality hence, the PNMC technique is applied to correct the NLOS effect. At third, assuming known the position of the reference devices, a multilateration technique is implemented to obtain the MU position. Finally, the localization system coupled with measurements demonstrates that the system outperforms the conventional time-based indoor localization schemes without using any tracking technique such as Kalman filters or Bayesian methods.

  8. TIME-BASED COMPETITION IN THE SUPPLY-CHAIN: THE ROLE OF THE LOGISTICS SERVICE PROVIDERS

    Directory of Open Access Journals (Sweden)

    Judit OLÁH

    2018-05-01

    Full Text Available Among the service industries, the analysis logistics as an academic field which has a great influence on firms’ creation of value and competitiveness, and within this the analysis of firms providing logistics services (3PLP, has become more relevant than in previous years. Among the expectations of logistics service providers, and among the sources of competitive advantage, are timeliness and flexibility, which can only be handled and measured together, because of the integration of services. At the same time, when supply chains (not corporations compete with each other, we must create the opportunity to manage chains beyond company boundaries. Our aim is to investigate the time-related problems of supply chains (and sections and logistics service providers, and their consequences and solutions. We have found that the development of time factors which appear and can be measured in the realization of logistics services contributes to the competitiveness of a logistics service company. The performance provided by companies that are integrated into the supply chain’s member companies and operate as flexible logistics service providers can have a significant impact on the (full operation and efficiency of the supply chain.

  9. Precision Neutron Time-of-Flight Detectors Provide Insight into NIF Implosion Dynamics

    Science.gov (United States)

    Schlossberg, David; Eckart, M. J.; Grim, G. P.; Hartouni, E. P.; Hatarik, R.; Moore, A. S.; Waltz, C. S.

    2017-10-01

    During inertial confinement fusion, higher-order moments of neutron time-of-flight (nToF) spectra can provide essential information for optimizing implosions. The nToF diagnostic suite at the National Ignition Facility (NIF) was recently upgraded to include novel, quartz Cherenkov detectors. These detectors exploit the rapid Cherenkov radiation process, in contrast with conventional scintillator decay times, to provide high temporal-precision measurements that support higher-order moment analyses. Preliminary measurements have been made on the NIF during several implosions and initial results are presented here. Measured line-of-sight asymmetries, for example in ion temperatures, will be discussed. Finally, advanced detector optimization is shown to advance accessible physics, with possibilities for energy discrimination, gamma source identification, and further reduction in quartz response times. Work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under contract DE-AC52-07NA27344.

  10. Decision peptide-driven: a free software tool for accurate protein quantification using gel electrophoresis and matrix assisted laser desorption ionization time of flight mass spectrometry.

    Science.gov (United States)

    Santos, Hugo M; Reboiro-Jato, Miguel; Glez-Peña, Daniel; Nunes-Miranda, J D; Fdez-Riverola, Florentino; Carvallo, R; Capelo, J L

    2010-09-15

    The decision peptide-driven tool implements a software application for assisting the user in a protocol for accurate protein quantification based on the following steps: (1) protein separation through gel electrophoresis; (2) in-gel protein digestion; (3) direct and inverse (18)O-labeling and (4) matrix assisted laser desorption ionization time of flight mass spectrometry, MALDI analysis. The DPD software compares the MALDI results of the direct and inverse (18)O-labeling experiments and quickly identifies those peptides with paralleled loses in different sets of a typical proteomic workflow. Those peptides are used for subsequent accurate protein quantification. The interpretation of the MALDI data from direct and inverse labeling experiments is time-consuming requiring a significant amount of time to do all comparisons manually. The DPD software shortens and simplifies the searching of the peptides that must be used for quantification from a week to just some minutes. To do so, it takes as input several MALDI spectra and aids the researcher in an automatic mode (i) to compare data from direct and inverse (18)O-labeling experiments, calculating the corresponding ratios to determine those peptides with paralleled losses throughout different sets of experiments; and (ii) allow to use those peptides as internal standards for subsequent accurate protein quantification using (18)O-labeling. In this work the DPD software is presented and explained with the quantification of protein carbonic anhydrase. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  11. Rotating Arc Jet Test Model: Time-Accurate Trajectory Heat Flux Replication in a Ground Test Environment

    Science.gov (United States)

    Laub, Bernard; Grinstead, Jay; Dyakonov, Artem; Venkatapathy, Ethiraj

    2011-01-01

    Though arc jet testing has been the proven method employed for development testing and certification of TPS and TPS instrumentation, the operational aspects of arc jets limit testing to selected, but constant, conditions. Flight, on the other hand, produces timevarying entry conditions in which the heat flux increases, peaks, and recedes as a vehicle descends through an atmosphere. As a result, we are unable to "test as we fly." Attempts to replicate the time-dependent aerothermal environment of atmospheric entry by varying the arc jet facility operating conditions during a test have proven to be difficult, expensive, and only partially successful. A promising alternative is to rotate the test model exposed to a constant-condition arc jet flow to yield a time-varying test condition at a point on a test article (Fig. 1). The model shape and rotation rate can be engineered so that the heat flux at a point on the model replicates the predicted profile for a particular point on a flight vehicle. This simple concept will enable, for example, calibration of the TPS sensors on the Mars Science Laboratory (MSL) aeroshell for anticipated flight environments.

  12. Rapid and Accurate Identification by Real-Time PCR of Biotoxin-Producing Dinoflagellates from the Family Gymnodiniaceae

    Directory of Open Access Journals (Sweden)

    Kirsty F. Smith

    2014-03-01

    Full Text Available The identification of toxin-producing dinoflagellates for monitoring programmes and bio-compound discovery requires considerable taxonomic expertise. It can also be difficult to morphologically differentiate toxic and non-toxic species or strains. Various molecular methods have been used for dinoflagellate identification and detection, and this study describes the development of eight real-time polymerase chain reaction (PCR assays targeting the large subunit ribosomal RNA (LSU rRNA gene of species from the genera Gymnodinium, Karenia, Karlodinium, and Takayama. Assays proved to be highly specific and sensitive, and the assay for G. catenatum was further developed for quantification in response to a bloom in Manukau Harbour, New Zealand. The assay estimated cell densities from environmental samples as low as 0.07 cells per PCR reaction, which equated to three cells per litre. This assay not only enabled conclusive species identification but also detected the presence of cells below the limit of detection for light microscopy. This study demonstrates the usefulness of real-time PCR as a sensitive and rapid molecular technique for the detection and quantification of micro-algae from environmental samples.

  13. Rapid and accurate identification by real-time PCR of biotoxin-producing dinoflagellates from the family gymnodiniaceae.

    Science.gov (United States)

    Smith, Kirsty F; de Salas, Miguel; Adamson, Janet; Rhodes, Lesley L

    2014-03-07

    The identification of toxin-producing dinoflagellates for monitoring programmes and bio-compound discovery requires considerable taxonomic expertise. It can also be difficult to morphologically differentiate toxic and non-toxic species or strains. Various molecular methods have been used for dinoflagellate identification and detection, and this study describes the development of eight real-time polymerase chain reaction (PCR) assays targeting the large subunit ribosomal RNA (LSU rRNA) gene of species from the genera Gymnodinium, Karenia, Karlodinium, and Takayama. Assays proved to be highly specific and sensitive, and the assay for G. catenatum was further developed for quantification in response to a bloom in Manukau Harbour, New Zealand. The assay estimated cell densities from environmental samples as low as 0.07 cells per PCR reaction, which equated to three cells per litre. This assay not only enabled conclusive species identification but also detected the presence of cells below the limit of detection for light microscopy. This study demonstrates the usefulness of real-time PCR as a sensitive and rapid molecular technique for the detection and quantification of micro-algae from environmental samples.

  14. Automatic Earthquake Shear Stress Measurement Method Developed for Accurate Time- Prediction Analysis of Forthcoming Major Earthquakes Along Shallow Active Faults

    Science.gov (United States)

    Serata, S.

    2006-12-01

    The Serata Stressmeter has been developed to measure and monitor earthquake shear stress build-up along shallow active faults. The development work made in the past 25 years has established the Stressmeter as an automatic stress measurement system to study timing of forthcoming major earthquakes in support of the current earthquake prediction studies based on statistical analysis of seismological observations. In early 1982, a series of major Man-made earthquakes (magnitude 4.5-5.0) suddenly occurred in an area over deep underground potash mine in Saskatchewan, Canada. By measuring underground stress condition of the mine, the direct cause of the earthquake was disclosed. The cause was successfully eliminated by controlling the stress condition of the mine. The Japanese government was interested in this development and the Stressmeter was introduced to the Japanese government research program for earthquake stress studies. In Japan the Stressmeter was first utilized for direct measurement of the intrinsic lateral tectonic stress gradient G. The measurement, conducted at the Mt. Fuji Underground Research Center of the Japanese government, disclosed the constant natural gradients of maximum and minimum lateral stresses in an excellent agreement with the theoretical value, i.e., G = 0.25. All the conventional methods of overcoring, hydrofracturing and deformation, which were introduced to compete with the Serata method, failed demonstrating the fundamental difficulties of the conventional methods. The intrinsic lateral stress gradient determined by the Stressmeter for the Japanese government was found to be the same with all the other measurements made by the Stressmeter in Japan. The stress measurement results obtained by the major international stress measurement work in the Hot Dry Rock Projects conducted in USA, England and Germany are found to be in good agreement with the Stressmeter results obtained in Japan. Based on this broad agreement, a solid geomechanical

  15. On the more accurate channel model and positioning based on time-of-arrival for visible light localization

    Science.gov (United States)

    Amini, Changeez; Taherpour, Abbas; Khattab, Tamer; Gazor, Saeed

    2017-01-01

    This paper presents an improved propagation channel model for the visible light in indoor environments. We employ this model to derive an enhanced positioning algorithm using on the relation between the time-of-arrivals (TOAs) and the distances for two cases either by assuming known or unknown transmitter and receiver vertical distances. We propose two estimators, namely the maximum likelihood estimator and an estimator by employing the method of moments. To have an evaluation basis for these methods, we calculate the Cramer-Rao lower bound (CRLB) for the performance of the estimations. We show that the proposed model and estimations result in a superior performance in positioning when the transmitter and receiver are perfectly synchronized in comparison to the existing state-of-the-art counterparts. Moreover, the corresponding CRLB of the proposed model represents almost about 20 dB reduction in the localization error bound in comparison with the previous model for some practical scenarios.

  16. Integrating Behavioral Health into Pediatric Primary Care: Implications for Provider Time and Cost.

    Science.gov (United States)

    Gouge, Natasha; Polaha, Jodi; Rogers, Rachel; Harden, Amy

    2016-12-01

    Integrating a behavioral health consultant (BHC) into primary care is associated with improved patient outcomes, fewer medical visits, and increased provider satisfaction; however, few studies have evaluated the feasibility of this model from an operations perspective. Specifically, time and cost have been identified as barriers to implementation. Our study aimed to examine time spent, patient volume, and revenue generated during days when the on-site BHC was available compared with days when the consultant was not. Data were collected across a 10-day period when a BHC provided services and 10 days when she was not available. Data included time stamps of patient direct care; providers' direct reports of problems raised; and a review of medical and administrative records, including billing codes and reimbursement. This study took place in a rural, stand-alone private pediatric primary care practice. The participants were five pediatric primary care providers (PCPs; two doctors of medicine, 1 doctor of osteopathy, 2 nurse practitioners) and two supervised doctoral students in psychology (BHCs). Pediatric patients (N = 668) and their parents also participated. On days when a BHC was present, medical providers spent 2 fewer minutes on average for every patient seen, saw 42% more patients, and collected $1142 more revenue than on days when no consultant was present. The time savings demonstrated on days when the consultant was available point to the efficiency and potential financial viability of this model. These results have important implications for the feasibility of hiring behavioral health professionals in a fee-for-service system. They have equally useful implications for the utility of moving to a bundled system of care in which collaborative practice is valued.

  17. Health care providers under pressure: making the most of challenging times.

    Science.gov (United States)

    Davis, Scott B; Robinson, Phillip J

    2010-01-01

    Whether the slowing economic recovery, tight credit markets, increasing costs, or the uncertainty surrounding health care reform, the health care industry faces some sizeable challenges. These factors have put considerable strain on the industry's traditional financing options that the industry has relied on in the past--bonds, banks, finance companies, private equity, venture capital, real estate investment trusts, private philanthropy, and grants. At the same time, providers are dealing with rising costs, lower reimbursement rates, shrinking demand for elective procedures, higher levels of charitable care and bad debt, and increased scrutiny of tax-exempt hospitals. Providers face these challenges against a back ground of uncertainty created by health care reform.

  18. An N-targeting real-time PCR strategy for the accurate detection of spring viremia of carp virus.

    Science.gov (United States)

    Shao, Ling; Xiao, Yu; He, Zhengkan; Gao, Longying

    2016-03-01

    Spring viremia of carp virus (SVCV) is a highly pathogenic agent of several economically important Cyprinidae fish species. Currently, there are no effective vaccines or drugs for this virus, and prevention of the disease mostly relies on prompt diagnosis. Previously, nested RT-PCR and RT-qPCR detection methods based on the glycoprotein gene G have been developed. However, the high genetic diversity of the G gene seriously limits the reliability of those methods. Compared with the G gene, phylogenetic analyses indicate that the nucleoprotein gene N is more conserved. Furthermore, studies in other members of the Rhabdoviridae family reveals that their gene transcription level follows the order N>P>M>G>L, indicating that an N gene based RT-PCR should have higher sensitivity. Therefore, two pairs of primers and two corresponding probes targeting the conserved regions of the N gene were designed. RT-qPCR assays demonstrated all primers and probes could detect phylogenetically distant isolates specifically and efficiently. Moreover, in artificially infected fish, the detected copy numbers of the N gene were much higher than those of the G gene in all tissues, and both the N and G gene copy numbers were highest in the kidney and spleen. Testing in 1100 farm-raised fish also showed that the N-targeting strategy was more reliable than the G-targeting methods. The method developed in this study provides a reliable tool for the rapid diagnosis of SVCV. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Accuration of Time Series and Spatial Interpolation Method for Prediction of Precipitation Distribution on the Geographical Information System

    Science.gov (United States)

    Prasetyo, S. Y. J.; Hartomo, K. D.

    2018-01-01

    The Spatial Plan of the Province of Central Java 2009-2029 identifies that most regencies or cities in Central Java Province are very vulnerable to landslide disaster. The data are also supported by other data from Indonesian Disaster Risk Index (In Indonesia called Indeks Risiko Bencana Indonesia) 2013 that suggest that some areas in Central Java Province exhibit a high risk of natural disasters. This research aims to develop an application architecture and analysis methodology in GIS to predict and to map rainfall distribution. We propose our GIS architectural application of “Multiplatform Architectural Spatiotemporal” and data analysis methods of “Triple Exponential Smoothing” and “Spatial Interpolation” as our significant scientific contribution. This research consists of 2 (two) parts, namely attribute data prediction using TES method and spatial data prediction using Inverse Distance Weight (IDW) method. We conduct our research in 19 subdistricts in the Boyolali Regency, Central Java Province, Indonesia. Our main research data is the biweekly rainfall data in 2000-2016 Climatology, Meteorology, and Geophysics Agency (In Indonesia called Badan Meteorologi, Klimatologi, dan Geofisika) of Central Java Province and Laboratory of Plant Disease Observations Region V Surakarta, Central Java. The application architecture and analytical methodology of “Multiplatform Architectural Spatiotemporal” and spatial data analysis methodology of “Triple Exponential Smoothing” and “Spatial Interpolation” can be developed as a GIS application framework of rainfall distribution for various applied fields. The comparison between the TES and IDW methods show that relative to time series prediction, spatial interpolation exhibit values that are approaching actual. Spatial interpolation is closer to actual data because computed values are the rainfall data of the nearest location or the neighbour of sample values. However, the IDW’s main weakness is that some

  20. Up-to-date, real-time localized ITS services provided on a mobile platform

    DEFF Research Database (Denmark)

    Tadayoni, Reza; Kloch, Christian

    2011-01-01

    and connection to the mobile platform, the smart phone provides the technologies and power to become the platform to provide and access up-to-date, real time infor-mation as requested by the drivers and becomes a central point for networking and coordinated actions. The purpose of this paper is to provide......-to-date infrastructure technology and is carried by lay-mans, like the smart-phones (with GPS receiver, Wi-Fi, Bluetooth, high speed cellular data connection and a large touch screen). With an 18 month replacement rate [1], and possibilities of combining navigational system, one-to-one communication, broadcast receiver...... in order to avoid local based solutions and to avoid proprietary solutions, a support that also shall be supported by political willingness above local level in order to realize the benefit of ITS....

  1. Impact of a narrative medicine programme on healthcare providers' empathy scores over time.

    Science.gov (United States)

    Chen, Po-Jui; Huang, Chien-Da; Yeh, San-Jou

    2017-07-05

    The cultivation of empathy for healthcare providers is an important issue in medical education. Narrative medicine (NM) has been shown to foster empathy. To our knowledge, there has been no research that examines whether a NM programme affects multi-professional healthcare providers' empathy. Our study aims to fill this gap by investigating whether a NM programme effects multi-professional healthcare providers' empathy. A pre-post questionnaire method was used.142 participants (n = 122 females) who attended the NM programme were divided into single (n = 58) and team groups (n = 84) on the basis of inter-professional education during a period of 2 months. Perceptions of the NM programme were collected using our developed questionnaire. Empathy levels were measured using the Chinese version of Jefferson Scale of Empathy - Healthcare Providers Version (JSE-HP) - at three time points: prior to (Time 1), immediately after (T2), and 1.5 years (T3) after the programme. Participants' perceptions about the NM programme (n = 116; n = 96 females) suggested an in enhancement of empathy (90.5%). Empathy scores via the JSE-HP increased after the NM programme (T1 mean 111.05, T2 mean 116.19) and were sustainable for 1.5 years (T3 mean 116.04) for all participants (F(2297) = 3.74, p empathy scores was found (F(1298) = 5.33, p empathy scores at T2, sustaining at T3, but males demonstrating a slow rise in empathy scores over time. NM programme as an educational tool for empathy is feasible. However, further research is needed to examine gender difference as it might be that males and females respond differently to a NM programme intervention.

  2. Simulation model for transcervical laryngeal injection providing real-time feedback.

    Science.gov (United States)

    Ainsworth, Tiffiny A; Kobler, James B; Loan, Gregory J; Burns, James A

    2014-12-01

    This study aimed to develop and evaluate a model for teaching transcervical laryngeal injections. A 3-dimensional printer was used to create a laryngotracheal framework based on de-identified computed tomography images of a human larynx. The arytenoid cartilages and intrinsic laryngeal musculature were created in silicone from clay casts and thermoplastic molds. The thyroarytenoid (TA) muscle was created with electrically conductive silicone using metallic filaments embedded in silicone. Wires connected TA muscles to an electrical circuit incorporating a cell phone and speaker. A needle electrode completed the circuit when inserted in the TA during simulated injection, providing real-time feedback of successful needle placement by producing an audible sound. Face validation by the senior author confirmed appropriate tactile feedback and anatomical realism. Otolaryngologists pilot tested the model and completed presimulation and postsimulation questionnaires. The high-fidelity simulation model provided tactile and audio feedback during needle placement, simulating transcervical vocal fold injections. Otolaryngology residents demonstrated higher comfort levels with transcervical thyroarytenoid injection on postsimulation questionnaires. This is the first study to describe a simulator for developing transcervical vocal fold injection skills. The model provides real-time tactile and auditory feedback that aids in skill acquisition. Otolaryngologists reported increased confidence with transcervical injection after using the simulator. © The Author(s) 2014.

  3. Control of Strobilurin Fungicides in Wheat Using Direct Analysis in Real Time Accurate Time-of-Flight and Desorption Electrospray Ionization Linear Ion Trap Mass Spectrometry

    NARCIS (Netherlands)

    Schurek, J.; Vaclavik, L.; Hooijerink, H.; Lacina, O.; Poustka, J.; Sharman, M.; Caldow, M.; Nielen, M.W.F.; Hajslova, J.

    2008-01-01

    Ambient mass spectrometry has been used for the analysis of strobilurin residues in wheat. The use of this novel, challenging technique, employing a direct analysis in a real time (DART) ion-source coupled with a time-of-flight mass spectrometer (TOF MS) and a desorption electrospray ionization

  4. A PC parallel port button box provides millisecond response time accuracy under Linux.

    Science.gov (United States)

    Stewart, Neil

    2006-02-01

    For psychologists, it is sometimes necessary to measure people's reaction times to the nearest millisecond. This article describes how to use the PC parallel port to receive signals from a button box to achieve millisecond response time accuracy. The workings of the parallel port, the corresponding port addresses, and a simple Linux program for controlling the port are described. A test of the speed and reliability of button box signal detection is reported. If the reader is moderately familiar with Linux, this article should provide sufficient instruction for him or her to build and test his or her own parallel port button box. This article also describes how the parallel port could be used to control an external apparatus.

  5. Prediction of collision cross section and retention time for broad scope screening in gradient reversed-phase liquid chromatography-ion mobility-high resolution accurate mass spectrometry

    DEFF Research Database (Denmark)

    Mollerup, Christian Brinch; Mardal, Marie; Dalsgaard, Petur Weihe

    2018-01-01

    artificial neural networks (ANNs). Prediction was based on molecular descriptors, 827 RTs, and 357 CCS values from pharmaceuticals, drugs of abuse, and their metabolites. ANN models for the prediction of RT or CCS separately were examined, and the potential to predict both from a single model......Exact mass, retention time (RT), and collision cross section (CCS) are used as identification parameters in liquid chromatography coupled to ion mobility high resolution accurate mass spectrometry (LC-IM-HRMS). Targeted screening analyses are now more flexible and can be expanded for suspect...

  6. Providing for transmission in times of scarcity: an ISO cannot do it all

    International Nuclear Information System (INIS)

    Allen, E.; Ilic, M.; Younes, Z.

    1999-01-01

    The main purpose of this paper is to point out issues critical for establishing a good transmission strategy in an energy market. First, it is suggested that a transmission strategy must be discussed in the context of a specific market structure. Responsibilities of a transmission system provider differ fundamentally, depending on the type of energy market it is supposed to serve. To show this, a summary of information assumed to be known to an Independent System Operator (ISO) in three energy market structures is given, i.e., (1) a mandatory ISO, (2) an entirely multilateral market and (3) a voluntary ISO. The differences between these three proposals concerning an ISO's responsibility for achieving systemwide efficiency and fair charges for transmission service, particularly at times of scarcity, are analyzed. It is shown that an ISO equipped with the present types of optimization tools for both reliability and efficiency is generally 'blind' to questions of fairness with respect to the individual market participants when providing transmission system support. In order to get around this problem, much more work will have to he done by the technical and regulatory communities. The only tools at an ISO's disposal at present are used for systemwide objectives, such as systemwide reliability. While some of this work is under way, it will take some time to develop the actual ISO tools necessary for implementing the fairness criterion metrics ('standards'), whichever ones the community arrives at. (Developing metrics of fair reliability contributions for the individual market participants is a nonunique process, and it may be very difficult to actually agree upon). Meanwhile, in order to have an ISO actively help energy markets in a fair and efficient way in realistic markets, which are likely to be voluntary ISOs, a system user must become an active part of decision making, indicating how much it wishes to use the system at times of scarcity and at which price. One

  7. An accurate, flexible and small optical fiber sensor: a novel technological breakthrough for real-time analysis of dynamic blood flow data in vivo.

    Directory of Open Access Journals (Sweden)

    Qiao-ying Yuan

    Full Text Available Because of the limitations of existing methods and techniques for directly obtaining real-time blood data, no accurate microflow in vivo real-time analysis method exists. To establish a novel technical platform for real-time in vivo detection and to analyze average blood pressure and other blood flow parameters, a small, accurate, flexible, and nontoxic Fabry-Perot fiber sensor was designed. The carotid sheath was implanted through intubation of the rabbit carotid artery (n = 8, and the blood pressure and other detection data were determined directly through the veins. The fiber detection results were compared with test results obtained using color Doppler ultrasound and a physiological pressure sensor recorder. Pairwise comparisons among the blood pressure results obtained using the three methods indicated that real-time blood pressure information obtained through the fiber sensor technique exhibited better correlation than the data obtained with the other techniques. The highest correlation (correlation coefficient of 0.86 was obtained between the fiber sensor and pressure sensor. The blood pressure values were positively related to the total cholesterol level, low-density lipoprotein level, number of red blood cells, and hemoglobin level, with correlation coefficients of 0.033, 0.129, 0.358, and 0.373, respectively. The blood pressure values had no obvious relationship with the number of white blood cells and high-density lipoprotein and had a negative relationship with triglyceride levels, with a correlation coefficient of -0.031. The average ambulatory blood pressure measured by the fiber sensor exhibited a negative correlation with the quantity of blood platelets (correlation coefficient of -0.839, P<0.05. The novel fiber sensor can thus obtain in vivo blood pressure data accurately, stably, and in real time; the sensor can also determine the content and status of the blood flow to some extent. Therefore, the fiber sensor can obtain

  8. An Assessment of Dialysis Provider's Attitudes towards Timing of Dialysis Initiation in Canada

    Directory of Open Access Journals (Sweden)

    Bikaramjit S Mann

    2014-04-01

    Full Text Available Background: Physicians' perceptions and opinions may influence when to initiate dialysis. Objective: To examine providers' perspectives and opinions regarding the timing of dialysis initiation. Design: Online survey. Setting: Community and academic dialysis practices in Canada. Participants: A nationally-representative sample of dialysis providers. Measurements and Methods: Dialysis providers opinions assessing reasons to initiate dialysis at low or high eGFR. Responses were obtained using a 9-point Likert scale. Early dialysis was defined as initiation of dialysis in an individual with an eGFR greater than or equal to 10.5 ml/min/m 2 . A detailed survey was emailed to all members of the Canadian Society of Nephrology (CSN in February 2013. The survey was designed and pre-tested to evaluate duration and ease of administration. Results: One hundred and forty one (25% response rate physicians participated in the survey. The majority were from urban, academic centres and practiced in regionally administered renal programs. Very few respondents had a formal policy regarding the timing of dialysis initiation or formally reviewed new dialysis starts (N = 4, 3.1%. The majority of respondents were either neutral or disagreed that late compared to early dialysis initiation improved outcomes (85–88%, had a negative impact on quality of life (89%, worsened AVF or PD use (84–90%, led to sicker patients (83% or was cost effective (61%. Fifty-seven percent of respondents felt uremic symptoms occurred earlier in patients with advancing age or co-morbid illness. Half (51.8% of the respondents felt there was an absolute eGFR at which they would initiate dialysis in an asymptomatic patient. The majority of respondents would initiate dialysis for classic indications for dialysis, such as volume overload (90.1% and cachexia (83.7% however a significant number chose other factors that may lead them to early dialysis initiation including avoiding an emergency (28

  9. The New Aptima HBV Quant Real-Time TMA Assay Accurately Quantifies Hepatitis B Virus DNA from Genotypes A to F.

    Science.gov (United States)

    Chevaliez, Stéphane; Dauvillier, Claude; Dubernet, Fabienne; Poveda, Jean-Dominique; Laperche, Syria; Hézode, Christophe; Pawlotsky, Jean-Michel

    2017-04-01

    Sensitive and accurate hepatitis B virus (HBV) DNA detection and quantification are essential to diagnose HBV infection, establish the prognosis of HBV-related liver disease, and guide the decision to treat and monitor the virological response to antiviral treatment and the emergence of resistance. Currently available HBV DNA platforms and assays are generally designed for batching multiple specimens within an individual run and require at least one full day of work to complete the analyses. The aim of this study was to evaluate the ability of the newly developed, fully automated, one-step Aptima HBV Quant assay to accurately detect and quantify HBV DNA in a large series of patients infected with different HBV genotypes. The limit of detection of the assay was estimated to be 4.5 IU/ml. The specificity of the assay was 100%. Intra-assay and interassay coefficients of variation ranged from 0.29% to 5.07% and 4.90% to 6.85%, respectively. HBV DNA levels from patients infected with HBV genotypes A to F measured with the Aptima HBV Quant assay strongly correlated with those measured by two commercial real-time PCR comparators (Cobas AmpliPrep/Cobas TaqMan HBV test, version 2.0, and Abbott RealTi m e HBV test). In conclusion, the Aptima HBV Quant assay is sensitive, specific, and reproducible and accurately quantifies HBV DNA in plasma samples from patients with chronic HBV infections of all genotypes, including patients on antiviral treatment with nucleoside or nucleotide analogues. The Aptima HBV Quant assay can thus confidently be used to detect and quantify HBV DNA in both clinical trials with new anti-HBV drugs and clinical practice. Copyright © 2017 American Society for Microbiology.

  10. Diurnal patterns of salivary cortisol and DHEA using a novel collection device: electronic monitoring confirms accurate recording of collection time using this device.

    Science.gov (United States)

    Laudenslager, Mark L; Calderone, Jacqueline; Philips, Sam; Natvig, Crystal; Carlson, Nichole E

    2013-09-01

    The accurate indication of saliva collection time is important for defining the diurnal decline in salivary cortisol as well as characterizing the cortisol awakening response. We tested a convenient and novel collection device for collecting saliva on strips of filter paper in a specially constructed booklet for determination of both cortisol and DHEA. In the present study, 31 healthy adults (mean age 43.5 years) collected saliva samples four times a day on three consecutive days using filter paper collection devices (Saliva Procurement and Integrated Testing (SPIT) booklet) which were maintained during the collection period in a large plastic bottle with an electronic monitoring cap. Subjects were asked to collect saliva samples at awakening, 30 min after awakening, before lunch and 600 min after awakening. The time of awakening and the time of collection before lunch were allowed to vary by each subjects' schedule. A reliable relationship was observed between the time recorded by the subject directly on the booklet and the time recorded by electronic collection device (n=286 observations; r(2)=0.98). However, subjects did not consistently collect the saliva samples at the two specific times requested, 30 and 600 min after awakening. Both cortisol and DHEA revealed diurnal declines. In spite of variance in collection times at 30 min and 600 min after awakening, the slope of the diurnal decline in both salivary cortisol and DHEA was similar when we compared collection tolerances of ±7.5 and ±15 min for each steroid. These unique collection booklets proved to be a reliable method for recording collection times by subjects as well as for estimating diurnal salivary cortisol and DHEA patterns. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Metabolic profiling of yeast culture using gas chromatography coupled with orthogonal acceleration accurate mass time-of-flight mass spectrometry: application to biomarker discovery.

    Science.gov (United States)

    Kondo, Elsuida; Marriott, Philip J; Parker, Rhiannon M; Kouremenos, Konstantinos A; Morrison, Paul; Adams, Mike

    2014-01-07

    Yeast and yeast cultures are frequently used as additives in diets of dairy cows. Beneficial effects from the inclusion of yeast culture in diets for dairy mammals have been reported, and the aim of this study was to develop a comprehensive analytical method for the accurate mass identification of the 'global' metabolites in order to differentiate a variety of yeasts at varying growth stages (Diamond V XP, Yea-Sacc and Levucell). Microwave-assisted derivatization for metabolic profiling is demonstrated through the analysis of differing yeast samples developed for cattle feed, which include a wide range of metabolites of interest covering a large range of compound classes. Accurate identification of the components was undertaken using GC-oa-ToFMS (gas chromatography-orthogonal acceleration-time-of-flight mass spectrometry), followed by principal component analysis (PCA) and orthogonal partial least squares discriminant analysis (OPLS-DA) for data reduction and biomarker discovery. Semi-quantification (fold changes in relative peak areas) was reported for metabolites identified as possible discriminative biomarkers (p-value 2), including D-ribose (four fold decrease), myo-inositol (five fold increase), L-phenylalanine (three fold increase), glucopyranoside (two fold increase), fructose (three fold increase) and threitol (three fold increase) respectively. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. A near-optimal low complexity sensor fusion technique for accurate indoor localization based on ultrasound time of arrival measurements from low-quality sensors

    Science.gov (United States)

    Mitilineos, Stelios A.; Argyreas, Nick D.; Thomopoulos, Stelios C. A.

    2009-05-01

    A fusion-based localization technique for location-based services in indoor environments is introduced herein, based on ultrasound time-of-arrival measurements from multiple off-the-shelf range estimating sensors which are used in a market-available localization system. In-situ field measurements results indicated that the respective off-the-shelf system was unable to estimate position in most of the cases, while the underlying sensors are of low-quality and yield highly inaccurate range and position estimates. An extensive analysis is performed and a model of the sensor-performance characteristics is established. A low-complexity but accurate sensor fusion and localization technique is then developed, which consists inof evaluating multiple sensor measurements and selecting the one that is considered most-accurate based on the underlying sensor model. Optimality, in the sense of a genie selecting the optimum sensor, is subsequently evaluated and compared to the proposed technique. The experimental results indicate that the proposed fusion method exhibits near-optimal performance and, albeit being theoretically suboptimal, it largely overcomes most flaws of the underlying single-sensor system resulting in a localization system of increased accuracy, robustness and availability.

  13. Time-accurate CFD conjugate analysis of transient measurements of the heat-transfer coefficient in a channel with pin fins

    Directory of Open Access Journals (Sweden)

    Tom I-P. Shih

    2013-03-01

    Full Text Available Heat-transfer coefficients (HTC on surfaces exposed to convection environments are often measured by transient techniques such as thermochromic liquid crystal (TLC or infrared thermography. In these techniques, the surface temperature is measured as a function of time, and that measurement is used with the exact solution for unsteady, zero-dimensional (0-D or one-dimensional (1-D heat conduction into a solid to calculate the local HTC. When using the 0-D or 1-D exact solutions, the transient techniques assume the HTC and the free-stream or bulk temperature characterizing the convection environment to be constants in addition to assuming the conduction into the solid to be 0-D or 1-D. In this study, computational fluid dynamics (CFD conjugate analyses were performed to examine the errors that might be invoked by these assumptions for a problem, where the free-stream/bulk temperature and the heat-transfer coefficient vary appreciably along the surface and where conduction into the solid may not be 0-D or 1-D. The problem selected to assess these errors is flow and heat transfer in a channel lined with a staggered array of pin fins. This conjugate study uses three-dimensional (3-D unsteady Reynolds-averaged Navier–Stokes (RANS closed by the shear-stress transport (SST turbulence model for the gas phase (wall functions not used and the Fourier law for the solid phase. The errors in the transient techniques are assessed by comparing the HTC predicted by the time-accurate conjugate CFD with those predicted by the 0-D and 1-D exact solutions, where the surface temperatures needed by the exact solutions are taken from the time-accurate conjugate CFD solution. Results obtained show that the use of the 1-D exact solution for the semi-infinite wall to give reasonably accurate “transient” HTC (less than 5% relative error. Transient techniques that use the 0-D exact solution for the pin fins were found to produce large errors (up to 160% relative error

  14. Providing written language services in the schools: the time is now.

    Science.gov (United States)

    Fallon, Karen A; Katz, Lauren A

    2011-01-01

    The current study was conducted to investigate the provision of written language services by school-based speech-language pathologists (SLPs). Specifically, the study examined SLPs' knowledge, attitudes, and collaborative practices in the area of written language services as well as the variables that impact provision of these services. Public school-based SLPs from across the country were solicited for participation in an online, Web-based survey. Data from 645 full-time SLPs from 49 states were evaluated using descriptive statistics and logistic regression. Many school-based SLPs reported not providing any services in the area of written language to students with written language weaknesses. Knowledge, attitudes, and collaborative practices were mixed. A logistic regression revealed three variables likely to predict high levels of service provision in the area of written language. Data from the current study revealed that many struggling readers and writers on school-based SLPs' caseloads are not receiving services from their SLPs. Implications for SLPs' preservice preparation, continuing education, and doctoral preparation are discussed.

  15. Plant Outage Time Savings Provided by Subcritical Physics Testing at Vogtle Unit 2

    International Nuclear Information System (INIS)

    Cupp, Philip; Heibel, M.D.

    2006-01-01

    The most recent core reload design verification physics testing done at Southern Nuclear Company's (SNC) Vogtle Unit 2, performed prior to initial power operations in operating cycle 12, was successfully completed while the reactor was at least 1% ΔK/K subcritical. The testing program used was the first application of the Subcritical Physics Testing (SPT) program developed by the Westinghouse Electric Company LLC. The SPT program centers on the application of the Westinghouse Subcritical Rod Worth Measurement (SRWM) methodology that was developed in cooperation with the Vogtle Reactor Engineering staff. The SRWM methodology received U. S. Nuclear Regulatory Commission (NRC) approval in August of 2005. The first application of the SPT program occurred at Vogtle Unit 2 in October of 2005. The results of the core design verification measurements obtained during the SPT program demonstrated excellent agreement with prediction, demonstrating that the predicted core characteristics were in excellent agreement with the actual operating characteristics of the core. This paper presents an overview of the SPT Program used at Vogtle Unit 2 during operating cycle 12, and a discussion of the critical path outage time savings the SPT program is capable of providing. (authors)

  16. Incorporation of exact boundary conditions into a discontinuous galerkin finite element method for accurately solving 2d time-dependent maxwell equations

    KAUST Repository

    Sirenko, Kostyantyn

    2013-01-01

    A scheme that discretizes exact absorbing boundary conditions (EACs) to incorporate them into a time-domain discontinuous Galerkin finite element method (TD-DG-FEM) is described. The proposed TD-DG-FEM with EACs is used for accurately characterizing transient electromagnetic wave interactions on two-dimensional waveguides. Numerical results demonstrate the proposed method\\'s superiority over the TD-DG-FEM that employs approximate boundary conditions and perfectly matched layers. Additionally, it is shown that the proposed method can produce the solution with ten-eleven digit accuracy when high-order spatial basis functions are used to discretize the Maxwell equations as well as the EACs. © 1963-2012 IEEE.

  17. Accurate mass analysis of ethanesulfonic acid degradates of acetochlor and alachlor using high-performance liquid chromatography and time-of-flight mass spectrometry

    Science.gov (United States)

    Thurman, E.M.; Ferrer, I.; Parry, R.

    2002-01-01

    Degradates of acetochlor and alachlor (ethanesulfonic acids, ESAs) were analyzed in both standards and in a groundwater sample using high-performance liquid chromatography-time-of-flight mass spectrometry with electrospray ionization. The negative pseudomolecular ion of the secondary amide of acetochlor ESA and alachlor ESA gave average masses of 256.0750??0.0049 amu and 270.0786??0.0064 amu respectively. Acetochlor and alachlor ESA gave similar masses of 314.1098??0.0061 amu and 314.1153??0.0048 amu; however, they could not be distinguished by accurate mass because they have the same empirical formula. On the other hand, they may be distinguished using positive-ion electrospray because of different fragmentation spectra, which did not occur using negative-ion electrospray.

  18. Judging the Probability of Hypotheses Versus the Impact of Evidence: Which Form of Inductive Inference Is More Accurate and Time-Consistent?

    Science.gov (United States)

    Tentori, Katya; Chater, Nick; Crupi, Vincenzo

    2016-04-01

    Inductive reasoning requires exploiting links between evidence and hypotheses. This can be done focusing either on the posterior probability of the hypothesis when updated on the new evidence or on the impact of the new evidence on the credibility of the hypothesis. But are these two cognitive representations equally reliable? This study investigates this question by comparing probability and impact judgments on the same experimental materials. The results indicate that impact judgments are more consistent in time and more accurate than probability judgments. Impact judgments also predict the direction of errors in probability judgments. These findings suggest that human inductive reasoning relies more on estimating evidential impact than on posterior probability. Copyright © 2015 Cognitive Science Society, Inc.

  19. Study on Providing Professors with Efficient Service Based on Time Management Strategy

    Science.gov (United States)

    Li, Chunlin; Liu, Mengchao; Wang, Yining

    2016-01-01

    Time management is the study to use time scientifically by deploying skills, techniques and means, and maximizing time value to help individuals or organizations efficiently complete tasks and achieve goals. University professor as a body is an important force in teaching and research. In order to ensure high-quality teaching, productive research,…

  20. Mitochondrial DNA as a non-invasive biomarker: Accurate quantification using real time quantitative PCR without co-amplification of pseudogenes and dilution bias

    International Nuclear Information System (INIS)

    Malik, Afshan N.; Shahni, Rojeen; Rodriguez-de-Ledesma, Ana; Laftah, Abas; Cunningham, Phil

    2011-01-01

    Highlights: → Mitochondrial dysfunction is central to many diseases of oxidative stress. → 95% of the mitochondrial genome is duplicated in the nuclear genome. → Dilution of untreated genomic DNA leads to dilution bias. → Unique primers and template pretreatment are needed to accurately measure mitochondrial DNA content. -- Abstract: Circulating mitochondrial DNA (MtDNA) is a potential non-invasive biomarker of cellular mitochondrial dysfunction, the latter known to be central to a wide range of human diseases. Changes in MtDNA are usually determined by quantification of MtDNA relative to nuclear DNA (Mt/N) using real time quantitative PCR. We propose that the methodology for measuring Mt/N needs to be improved and we have identified that current methods have at least one of the following three problems: (1) As much of the mitochondrial genome is duplicated in the nuclear genome, many commonly used MtDNA primers co-amplify homologous pseudogenes found in the nuclear genome; (2) use of regions from genes such as β-actin and 18S rRNA which are repetitive and/or highly variable for qPCR of the nuclear genome leads to errors; and (3) the size difference of mitochondrial and nuclear genomes cause a 'dilution bias' when template DNA is diluted. We describe a PCR-based method using unique regions in the human mitochondrial genome not duplicated in the nuclear genome; unique single copy region in the nuclear genome and template treatment to remove dilution bias, to accurately quantify MtDNA from human samples.

  1. 3T MRI of the knee with optimised isotropic 3D sequences. Accurate delineation of intra-articular pathology without prolonged acquisition times

    Energy Technology Data Exchange (ETDEWEB)

    Abdulaal, Osamah M.; Rainford, Louise; Galligan, Marie; McGee, Allison [University College Dublin, Radiography and Diagnostic Imaging, School of Medicine, Belfield, Dublin (Ireland); MacMahon, Peter; Kavanagh, Eoin [Mater Misericordiae University Hospital, Department of Radiology, Dublin (Ireland); University College Dublin, School of Medicine, Dublin (Ireland); Cashman, James [Mater Misericordiae University Hospital, Department of Orthopaedics, Dublin (Ireland); University College Dublin, School of Medicine, Dublin (Ireland)

    2017-11-15

    To investigate optimised isotropic 3D turbo spin echo (TSE) and gradient echo (GRE)-based pulse sequences for visualisation of articular cartilage lesions within the knee joint. Optimisation of experimental imaging sequences was completed using healthy volunteers (n=16) with a 3-Tesla (3T) MRI scanner. Imaging of patients with knee cartilage abnormalities (n=57) was then performed. Acquired sequences included 3D proton density-weighted (PDW) TSE (SPACE) with and without fat-suppression (FS), and T2*W GRE (TrueFISP) sequences, with acquisition times of 6:51, 6:32 and 5:35 min, respectively. One hundred sixty-one confirmed cartilage lesions were detected and categorised (Grade II n=90, Grade III n=71). The highest sensitivity and specificity for detecting cartilage lesions were obtained with TrueFISP with values of 84.7% and 92%, respectively. Cartilage SNR mean for PDW SPACE-FS was the highest at 72.2. TrueFISP attained the highest CNR means for joint fluid/cartilage (101.5) and joint fluid/ligament (156.5), and the lowest CNR for cartilage/meniscus (48.5). Significant differences were identified across the three sequences for all anatomical structures with respect to SNR and CNR findings (p-value <0.05). Isotropic TrueFISP at 3T, optimised for acquisition time, accurately detects cartilage defects, although it demonstrated the lowest contrast between cartilage and meniscus. (orig.)

  2. A Review of Wearable Technologies for Elderly Care that Can Accurately Track Indoor Position, Recognize Physical Activities and Monitor Vital Signs in Real Time

    Directory of Open Access Journals (Sweden)

    Zhihua Wang

    2017-02-01

    Full Text Available Rapid growth of the aged population has caused an immense increase in the demand for healthcare services. Generally, the elderly are more prone to health problems compared to other age groups. With effective monitoring and alarm systems, the adverse effects of unpredictable events such as sudden illnesses, falls, and so on can be ameliorated to some extent. Recently, advances in wearable and sensor technologies have improved the prospects of these service systems for assisting elderly people. In this article, we review state-of-the-art wearable technologies that can be used for elderly care. These technologies are categorized into three types: indoor positioning, activity recognition and real time vital sign monitoring. Positioning is the process of accurate localization and is particularly important for elderly people so that they can be found in a timely manner. Activity recognition not only helps ensure that sudden events (e.g., falls will raise alarms but also functions as a feasible way to guide people’s activities so that they avoid dangerous behaviors. Since most elderly people suffer from age-related problems, some vital signs that can be monitored comfortably and continuously via existing techniques are also summarized. Finally, we discussed a series of considerations and future trends with regard to the construction of “smart clothing” system.

  3. A Review of Wearable Technologies for Elderly Care that Can Accurately Track Indoor Position, Recognize Physical Activities and Monitor Vital Signs in Real Time

    Science.gov (United States)

    Wang, Zhihua; Yang, Zhaochu; Dong, Tao

    2017-01-01

    Rapid growth of the aged population has caused an immense increase in the demand for healthcare services. Generally, the elderly are more prone to health problems compared to other age groups. With effective monitoring and alarm systems, the adverse effects of unpredictable events such as sudden illnesses, falls, and so on can be ameliorated to some extent. Recently, advances in wearable and sensor technologies have improved the prospects of these service systems for assisting elderly people. In this article, we review state-of-the-art wearable technologies that can be used for elderly care. These technologies are categorized into three types: indoor positioning, activity recognition and real time vital sign monitoring. Positioning is the process of accurate localization and is particularly important for elderly people so that they can be found in a timely manner. Activity recognition not only helps ensure that sudden events (e.g., falls) will raise alarms but also functions as a feasible way to guide people’s activities so that they avoid dangerous behaviors. Since most elderly people suffer from age-related problems, some vital signs that can be monitored comfortably and continuously via existing techniques are also summarized. Finally, we discussed a series of considerations and future trends with regard to the construction of “smart clothing” system. PMID:28208620

  4. Using a Time-Driven Activity-Based Costing Model To Determine the Actual Cost of Services Provided by a Transgenic Core.

    Science.gov (United States)

    Gerwin, Philip M; Norinsky, Rada M; Tolwani, Ravi J

    2018-03-01

    Laboratory animal programs and core laboratories often set service rates based on cost estimates. However, actual costs may be unknown, and service rates may not reflect the actual cost of services. Accurately evaluating the actual costs of services can be challenging and time-consuming. We used a time-driven activity-based costing (ABC) model to determine the cost of services provided by a resource laboratory at our institution. The time-driven approach is a more efficient approach to calculating costs than using a traditional ABC model. We calculated only 2 parameters: the time required to perform an activity and the unit cost of the activity based on employee cost. This method allowed us to rapidly and accurately calculate the actual cost of services provided, including microinjection of a DNA construct, microinjection of embryonic stem cells, embryo transfer, and in vitro fertilization. We successfully implemented a time-driven ABC model to evaluate the cost of these services and the capacity of labor used to deliver them. We determined how actual costs compared with current service rates. In addition, we determined that the labor supplied to conduct all services (10,645 min/wk) exceeded the practical labor capacity (8400 min/wk), indicating that the laboratory team was highly efficient and that additional labor capacity was needed to prevent overloading of the current team. Importantly, this time-driven ABC approach allowed us to establish a baseline model that can easily be updated to reflect operational changes or changes in labor costs. We demonstrated that a time-driven ABC model is a powerful management tool that can be applied to other core facilities as well as to entire animal programs, providing valuable information that can be used to set rates based on the actual cost of services and to improve operating efficiency.

  5. Vis-A-Plan /visualize a plan/ management technique provides performance-time scale

    Science.gov (United States)

    Ranck, N. H.

    1967-01-01

    Vis-A-Plan is a bar-charting technique for representing and evaluating project activities on a performance-time basis. This rectilinear method presents the logic diagram of a project as a series of horizontal time bars. It may be used supplementary to PERT or independently.

  6. Working and Providing Care: Increasing Student Engagement for Part-Time Community College Students

    Science.gov (United States)

    Leingang, Daniel James

    2017-01-01

    The purpose of this study was to examine the relationship among external time obligations of work and care giving by part-time students, their participation within structured group learning experiences, and student engagement. The Structured Group Learning Experiences (SGLEs) explored within this study include community college programming…

  7. RiTE: Providing On-Demand Data for Right-Time Data Warehousing

    DEFF Research Database (Denmark)

    Thomsen, Christian; Pedersen, Torben Bach; Lehner, Wolfgang

    2008-01-01

    Data warehouses (DWs) have traditionally been loaded with data at regular time intervals, e.g., monthly, weekly, or daily, using fast bulk loading techniques. Recently, the trend is to insert all (or only some) new source data very quickly into DWs, called near-realtime DWs (right-time DWs...

  8. Speedometer app videos to provide real-world velocity-time graph data 1: rail travel

    Science.gov (United States)

    King, Julien

    2018-03-01

    The use of modern rail travel as a source of real-life velocity-time data to aid in the teaching of velocity and acceleration is discussed. A technique for using GPS speedometer apps to produce videos of velocity and time figures during a rail journey is described. The technique is applied to a UK rail journey, demonstrating how students can use its results to produce a velocity-time graph from which acceleration and deceleration figures can be calculated. These are compared with theoretical maximum figures, calculated from the train’s technical specification.

  9. Online genetic counseling from the providers' perspective : counselors' evaluations and a time and cost analysis

    NARCIS (Netherlands)

    Otten, Ellen; Birnie, Erwin; Ranchor, Adelita V.; van Langen, Irene M.

    Telemedicine applications are increasingly being introduced in patient care in various disciplines, including clinical genetics, mainly to increase access to care and to reduce time and costs for patients and professionals. Most telegenetics reports describe applications in large geographical areas,

  10. Two-way time transfer via optical fiber providing subpicosecond precision and high temperature stability

    Czech Academy of Sciences Publication Activity Database

    Kodet, J.; Pánek, Petr; Procházka, I.

    2015-01-01

    Roč. 53, č. 1 (2015), s. 18-26 ISSN 0026-1394 Institutional support: RVO:67985882 Keywords : optical fiber * time transfer * TWOTT Subject RIV: JB - Sensors, Measurment, Regulation Impact factor: 2.500, year: 2015

  11. Two-way time transfer via optical fiber providing subpicosecond precision and high temperature stability

    Czech Academy of Sciences Publication Activity Database

    Kodet, J.; Pánek, Petr; Procházka, I.

    2016-01-01

    Roč. 53, č. 1 (2016), s. 18-26 ISSN 0026-1394 Institutional support: RVO:67985882 Keywords : TWOTT * Time transfer * Optical fiber Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 3.411, year: 2016

  12. Time to standardise levels of care amongst Out-of-Hospital Emergency Care providers in Africa

    OpenAIRE

    Mould-Millman, N.K.; Stein, C.; Wallis, L.A.

    2016-01-01

    The African Federation for Emergency Medicine’s Out-of-Hospital Emergency Care (OHEC) Committee convened 15 experts from various OHEC systems in Africa to participate in a consensus process to define levels of care within which providers in African OHEC systems should safely and effectively function. The expert panel concluded that four provider levels were relevant for African OHEC systems: (i) first aid, (ii) basic life support, (iii) intermediate life support, and (iv) advanced life suppor...

  13. Development of the Japanese version of an information aid to provide accurate information on prognosis to patients with advanced non-small-cell lung cancer receiving chemotherapy: a pilot study.

    Science.gov (United States)

    Nakano, Kikuo; Kitahara, Yoshihiro; Mito, Mineyo; Seno, Misato; Sunada, Shoji

    2018-02-27

    Without explicit prognostic information, patients may overestimate their life expectancy and make poor choices at the end of life. We sought to design the Japanese version of an information aid (IA) to provide accurate information on prognosis to patients with advanced non-small-cell lung cancer (NSCLC) and to assess the effects of the IA on hope, psychosocial status, and perception of curability. We developed the Japanese version of an IA, which provided information on survival and cure rates as well as numerical survival estimates for patients with metastatic NSCLC receiving first-line chemotherapy. We then assessed the pre- and post-intervention effects of the IA on hope, anxiety, and perception of curability and treatment benefits. A total of 20 (95%) of 21 patients (65% male; median age, 72 years) completed the IA pilot test. Based on the results, scores on the Distress and Impact Thermometer screening tool for adjustment disorders and major depression tended to decrease (from 4.5 to 2.5; P = 0.204), whereas no significant changes were seen in scores for anxiety on the Japanese version of the Support Team Assessment Schedule or in scores on the Hearth Hope Index (from 41.9 to 41.5; p = 0.204). The majority of the patients (16/20, 80%) had high expectations regarding the curative effects of chemotherapy. The Japanese version of the IA appeared to help patients with NSCLC maintain hope, and did not increase their anxiety when they were given explicit prognostic information; however, the IA did not appear to help such patients understand the goal of chemotherapy. Further research is needed to test the findings in a larger sample and measure the outcomes of explicit prognostic information on hope, psychological status, and perception of curability.

  14. Exploratory Data Analysis of Acceleration Signals to Select Light-Weight and Accurate Features for Real-Time Activity Recognition on Smartphones

    Directory of Open Access Journals (Sweden)

    Seok-Won Lee

    2013-09-01

    Full Text Available Smartphone-based activity recognition (SP-AR recognizes users’ activities using the embedded accelerometer sensor. Only a small number of previous works can be classified as online systems, i.e., the whole process (pre-processing, feature extraction, and classification is performed on the device. Most of these online systems use either a high sampling rate (SR or long data-window (DW to achieve high accuracy, resulting in short battery life or delayed system response, respectively. This paper introduces a real-time/online SP-AR system that solves this problem. Exploratory data analysis was performed on acceleration signals of 6 activities, collected from 30 subjects, to show that these signals are generated by an autoregressive (AR process, and an accurate AR-model in this case can be built using a low SR (20 Hz and a small DW (3 s. The high within class variance resulting from placing the phone at different positions was reduced using kernel discriminant analysis to achieve position-independent recognition. Neural networks were used as classifiers. Unlike previous works, true subject-independent evaluation was performed, where 10 new subjects evaluated the system at their homes for 1 week. The results show that our features outperformed three commonly used features by 40% in terms of accuracy for the given SR and DW.

  15. Exploratory data analysis of acceleration signals to select light-weight and accurate features for real-time activity recognition on smartphones.

    Science.gov (United States)

    Khan, Adil Mehmood; Siddiqi, Muhammad Hameed; Lee, Seok-Won

    2013-09-27

    Smartphone-based activity recognition (SP-AR) recognizes users' activities using the embedded accelerometer sensor. Only a small number of previous works can be classified as online systems, i.e., the whole process (pre-processing, feature extraction, and classification) is performed on the device. Most of these online systems use either a high sampling rate (SR) or long data-window (DW) to achieve high accuracy, resulting in short battery life or delayed system response, respectively. This paper introduces a real-time/online SP-AR system that solves this problem. Exploratory data analysis was performed on acceleration signals of 6 activities, collected from 30 subjects, to show that these signals are generated by an autoregressive (AR) process, and an accurate AR-model in this case can be built using a low SR (20 Hz) and a small DW (3 s). The high within class variance resulting from placing the phone at different positions was reduced using kernel discriminant analysis to achieve position-independent recognition. Neural networks were used as classifiers. Unlike previous works, true subject-independent evaluation was performed, where 10 new subjects evaluated the system at their homes for 1 week. The results show that our features outperformed three commonly used features by 40% in terms of accuracy for the given SR and DW.

  16. Precision Timing of PSR J0437-4715: An Accurate Pulsar Distance, a High Pulsar Mass, and a Limit on the Variation of Newton's Gravitational Constant

    Science.gov (United States)

    Verbiest, J. P. W.; Bailes, M.; van Straten, W.; Hobbs, G. B.; Edwards, R. T.; Manchester, R. N.; Bhat, N. D. R.; Sarkissian, J. M.; Jacoby, B. A.; Kulkarni, S. R.

    2008-05-01

    Analysis of 10 years of high-precision timing data on the millisecond pulsar PSR J0437-4715 has resulted in a model-independent kinematic distance based on an apparent orbital period derivative, dot Pb , determined at the 1.5% level of precision (Dk = 157.0 +/- 2.4 pc), making it one of the most accurate stellar distance estimates published to date. The discrepancy between this measurement and a previously published parallax distance estimate is attributed to errors in the DE200 solar system ephemerides. The precise measurement of dot Pb allows a limit on the variation of Newton's gravitational constant, |Ġ/G| <= 23 × 10-12 yr-1. We also constrain any anomalous acceleration along the line of sight to the pulsar to |a⊙/c| <= 1.5 × 10-18 s-1 at 95% confidence, and derive a pulsar mass, mpsr = 1.76 +/- 0.20 M⊙, one of the highest estimates so far obtained.

  17. An algorithm to provide real time neutral beam substitution in the DIII-D tokamak

    International Nuclear Information System (INIS)

    Phillips, J.C.; Greene, K.L.; Hyatt, A.W.; McHarg, B.B. Jr.; Penaflor, B.G.

    1999-06-01

    A key component of the DIII-D tokamak fusion experiment is a flexible and easy to expand digital control system which actively controls a large number of parameters in real-time. These include plasma shape, position, density, and total stored energy. This system, known as the PCS (plasma control system), also has the ability to directly control auxiliary plasma heating systems, such as the 20 MW of neutral beams routinely used on DIII-D. This paper describes the implementation of a real-time algorithm allowing substitution of power from one neutral beam for another, given a fault in the originally scheduled beam. Previously, in the event of a fault in one of the neutral beams, the actual power profile for the shot might be deficient, resulting in a less useful or wasted shot. Using this new real-time algorithm, a stand by neutral beam may substitute within milliseconds for one which has faulted. Since single shots can have substantial value, this is an important advance to DIII-D's capabilities and utilization. Detailed results are presented, along with a description not only of the algorithm but of the simulation setup required to prove the algorithm without the costs normally associated with using physics operations time

  18. Methods for providing decision makers with optimal solutions for multiple objectives that change over time

    CSIR Research Space (South Africa)

    Greeff, M

    2010-09-01

    Full Text Available Decision making - with the goal of finding the optimal solution - is an important part of modern life. For example: In the control room of an airport, the goals or objectives are to minimise the risk of airplanes colliding, minimise the time that a...

  19. Prediction of collision cross section and retention time for broad scope screening in gradient reversed-phase liquid chromatography-ion mobility-high resolution accurate mass spectrometry.

    Science.gov (United States)

    Mollerup, Christian Brinch; Mardal, Marie; Dalsgaard, Petur Weihe; Linnet, Kristian; Barron, Leon Patrick

    2018-03-23

    Exact mass, retention time (RT), and collision cross section (CCS) are used as identification parameters in liquid chromatography coupled to ion mobility high resolution accurate mass spectrometry (LC-IM-HRMS). Targeted screening analyses are now more flexible and can be expanded for suspect and non-targeted screening. These allow for tentative identification of new compounds, and in-silico predicted reference values are used for improving confidence and filtering false-positive identifications. In this work, predictions of both RT and CCS values are performed with machine learning using artificial neural networks (ANNs). Prediction was based on molecular descriptors, 827 RTs, and 357 CCS values from pharmaceuticals, drugs of abuse, and their metabolites. ANN models for the prediction of RT or CCS separately were examined, and the potential to predict both from a single model was investigated for the first time. The optimized combined RT-CCS model was a four-layered multi-layer perceptron ANN, and the 95th prediction error percentiles were within 2 min RT error and 5% relative CCS error for the external validation set (n = 36) and the full RT-CCS dataset (n = 357). 88.6% (n = 733) of predicted RTs were within 2 min error for the full dataset. Overall, when using 2 min RT error and 5% relative CCS error, 91.9% (n = 328) of compounds were retained, while 99.4% (n = 355) were retained when using at least one of these thresholds. This combined prediction approach can therefore be useful for rapid suspect/non-targeted screening involving HRMS, and will support current workflows. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. A METHOD AND AN APPARATUS FOR PROVIDING TIMING SIGNALS TO A NUMBER OF CIRCUITS, AN INTEGRATED CIRCUIT AND A NODE

    DEFF Research Database (Denmark)

    2006-01-01

    A method of providing or transporting a timing signal between a number of circuits, electrical or optical, where each circuit is fed by a node. The nodes forward timing signals between each other, and at least one node is adapted to not transmit a timing signal before having received a timing...... signal from at least two nodes. In this manner, the direction of the timing skew between nodes and circuits is known and data transport between the circuits made easier....

  1. Online genetic counseling from the providers' perspective: counselors' evaluations and a time and cost analysis

    Science.gov (United States)

    Otten, Ellen; Birnie, Erwin; Ranchor, Adelita V; van Langen, Irene M

    2016-01-01

    Telemedicine applications are increasingly being introduced in patient care in various disciplines, including clinical genetics, mainly to increase access to care and to reduce time and costs for patients and professionals. Most telegenetics reports describe applications in large geographical areas, showing positive patients' and professionals' satisfaction. One economic analysis published thus far reported lower costs than in-person care. We hypothesized that telegenetics can also be beneficial from the professional's view in relatively small geographical areas. We performed a pilot study in the Northern Netherlands of 51 home-based online counseling sessions for cardiogenetic and oncogenetic cascade screening, and urgent prenatal counseling. Previously, we showed patient satisfaction, anxiety, and perceived control of online counseling to be comparable to in-person counseling. This study focuses on expectations, satisfaction, and practical evaluations of the involved counselors, and the impact in terms of time and costs. Most counselors expected disadvantages of online counseling for themselves and their patients, mainly concerning insufficient non-verbal communication; few expected advantages for themselves. Afterwards, counselors additionally raised the disadvantage of insufficient verbal communication, and reported frequent technical problems. Their overall mean telemedicine satisfaction itemscore was 3.38 before, and 2.95 afterwards, being afterwards slightly below the minimum level we set for a satisfactory result. We estimated reduced time and costs by online counseling with about 8% and 10–12%, respectively. We showed online genetic counseling to be effective, feasible and cost-efficient, but technical improvements are needed to increase counselors' satisfaction. PMID:26785833

  2. Different and Similar at the Same Time. Cultural Competence through the Leans of Healthcare Providers.

    Science.gov (United States)

    Dell'Aversana, Giuseppina; Bruno, Andreina

    2017-01-01

    Cultural competence (CC) for professionals and organizations has been recognized as a key strategy to reduce health care inequalities for migrants and to promote responsiveness to diversity. For decades its main aim has been matching health services to the cultural needs of migrant users. Otherwise literature highlighted the need to find a pragmatic middle way between the 'static' and the 'dynamic' views of culture that are recognizable in CC approaches. A pragmatic middle way to CC will be proposed as the way to respect diversity, even responding to cultural issues, without stereotyping or discriminating. To understand conditions that favor this pragmatic middle way this study aims to explore: (1) perceptions of healthcare providers in managing diversity; (2) strategies used to meet health needs at a professional and organizational level. A qualitative case study was conducted in a healthcare service renowned for its engagement in migrant sensitive care. Four different professional figures involved in CC strategies at different levels, both managerial and non-managerial, were interviewed. Data were analyzed using thematic analysis. Findings indicated that dealing with diversity poses challenges for healthcare providers, by confronting them with multilevel barriers to quality of care. A pragmatic middle way to CC seems to rely on complex understanding of the interaction between patients social conditions and the capacity of the institutional system to promote equity. Professional and organizational strategies, such as inter-professional and intersectional collaboration, cultural food adaptation and professional training can enhance quality of care, patient compliance responding to social and cultural needs.

  3. Does the real-time ultrasound guidance provide safer venipuncture in implantable venous port implantation?

    Science.gov (United States)

    Yıldırım, İlknur; Tütüncü, Ayşe Çiğdem; Bademler, Süleyman; Özgür, İlker; Demiray, Mukaddes; Karanlık, Hasan

    2018-03-01

    To examine whether the real-time ultrasound-guided venipuncture for implantable venous port placement is safer than the traditional venipuncture. The study analyzed the results of 2153 venous ports placed consecutively from January 2009 to January 2016. A total of 922 patients in group 1 and 1231 patients in group 2 were admitted with venous port placed using the traditional landmark subclavian approach and real-time ultrasound-guided axillary approach, respectively. Sociodemographic characteristics of patients, early (pneumothorax, pinch-off syndrome, arterial puncture, hematoma, and malposition arrhythmia) and late (deep vein thrombosis, obstruction, infection, erosion-dehiscence, and rotation of the port chamber) complications and the association of these complications with the implantation method were evaluated. There were no significant differences in the sociodemographic characteristics of the patients between the two groups. The overall and early complications in group 2 were significantly lower than those in group 1. Pinch-off syndrome only developed in group 1. Seven patients and two patients had pneumothorax in groups 1 and 2, respectively. Puncture number was significantly associated with the development of the overall complications. The ultrasound-guided axillary approach may be preferred as a method to reduce the risk of both early and late complications. Large, randomized, controlled prospective trials will be helpful in determining a safer implantable venous port implantation technique.

  4. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry for fast and accurate identification of clinically relevant Aspergillus species.

    Science.gov (United States)

    Alanio, A; Beretti, J-L; Dauphin, B; Mellado, E; Quesne, G; Lacroix, C; Amara, A; Berche, P; Nassif, X; Bougnoux, M-E

    2011-05-01

    New Aspergillus species have recently been described with the use of multilocus sequencing in refractory cases of invasive aspergillosis. The classical phenotypic identification methods routinely used in clinical laboratories failed to identify them adequately. Some of these Aspergillus species have specific patterns of susceptibility to antifungal agents, and misidentification may lead to inappropriate therapy. We developed a matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS)-based strategy to adequately identify Aspergillus species to the species level. A database including the reference spectra of 28 clinically relevant species from seven Aspergillus sections (five common and 23 unusual species) was engineered. The profiles of young and mature colonies were analysed for each reference strain, and species-specific spectral fingerprints were identified. The performance of the database was then tested on 124 clinical and 16 environmental isolates previously characterized by partial sequencing of the β-tubulin and calmodulin genes. One hundred and thirty-eight isolates of 140 (98.6%) were correctly identified. Two atypical isolates could not be identified, but no isolate was misidentified (specificity: 100%). The database, including species-specific spectral fingerprints of young and mature colonies of the reference strains, allowed identification regardless of the maturity of the clinical isolate. These results indicate that MALDI-TOF MS is a powerful tool for rapid and accurate identification of both common and unusual species of Aspergillus. It can give better results than morphological identification in clinical laboratories. © 2010 The Authors. Clinical Microbiology and Infection © 2010 European Society of Clinical Microbiology and Infectious Diseases.

  5. Providing reliable energy in a time of constraints : a North American concern

    International Nuclear Information System (INIS)

    Egan, T.; Turk, E.

    2008-04-01

    The reliability of the North American electricity grid was discussed. Government initiatives designed to control carbon dioxide (CO 2 ) and other emissions in some regions of Canada may lead to electricity supply constraints in other regions. A lack of investment in transmission infrastructure has resulted in constraints within the North American transmission grid, and the growth of smaller projects is now raising concerns about transmission capacity. Labour supply shortages in the electricity industry are also creating concerns about the long-term security of the electricity market. Measures to address constraints must be considered in the current context of the North American electricity system. The extensive transmission interconnects and integration between the United States and Canada will provide a framework for greater trade and market opportunities between the 2 countries. Coordinated actions and increased integration will enable Canada and the United States to increase the reliability of electricity supply. However, both countries must work cooperatively to increase generation supply using both mature and emerging technologies. The cross-border transmission grid must be enhanced by increasing transmission capacity as well as by implementing new reliability rules, building new infrastructure, and ensuring infrastructure protection. Barriers to cross-border electricity trade must be identified and avoided. Demand-side and energy efficiency measures must also be implemented. It was concluded that both countries must focus on developing strategies for addressing the environmental concerns related to electricity production. 6 figs

  6. Accurate Mass GC/LC-Quadrupole Time of Flight Mass Spectrometry Analysis of Fatty Acids and Triacylglycerols of Spicy Fruits from the Apiaceae Family

    Directory of Open Access Journals (Sweden)

    Thao Nguyen

    2015-12-01

    Full Text Available The triacylglycerol (TAG structure and the regio-stereospecific distribution of fatty acids (FA of seed oils from most of the Apiaceae family are not well documented. The TAG structure ultimately determines the final physical properties of the oils and the position of FAs in the TAG molecule affects the digestion; absorption and metabolism; and physical and technological properties of TAGs. Fixed oils from the fruits of dill (Anethum graveolens, caraway (Carum carvi, cumin (Cuminum cyminum, coriander (Coriandrum sativum, anise (Pimpinella anisum, carrot (Daucus carota, celery (Apium graveolens, fennel (Foeniculum vulgare, and Khella (Ammi visnaga, all from the Apiaceae family, were extracted at room temperature in chloroform/methanol (2:1 v/v using percolators. Crude lipids were fractionated by solid phase extraction to separate neutral triacylglycerols (TAGs from other lipids components. Neutral TAGs were subjected to transesterification process to convert them to their corresponding fatty acids methyl esters (FAMES using 1% boron trifluoride (BF3 in methanol. FAMES were analyzed by gas chromatography-quadrupole time of flight (GC-QTOF mass spectrometry. Triglycerides were analyzed using high performance liquid chromatography-quadrupole time of flight (LC-QTOF mass spectrometry. Petroselinic acid was the major fatty acid in all samples ranging from 57% of the total fatty acids in caraway up to 82% in fennel. All samples contained palmitic (16:0, palmitoleic (C16:1n-9, stearic (C18:0, petroselinic (C18:1n-12, linoleic (C18:2n-6, linolinic (18:3n-3, and arachidic (C20:0 acids. TAG were analyzed using LC-QTOF for accurate mass identification and mass spectrometry/mass spectrometry (MS/MS techniques for regiospesific elucidation of the identified TAGs. Five major TAGs were detected in all samples but with different relative concentrations in all of the tested samples. Several other TAGs were detected as minor components and were present in some

  7. The Online GVP/USGS Weekly Volcanic Activity Report: Providing Timely Information About Worldwide Volcanism

    Science.gov (United States)

    Mayberry, G. C.; Guffanti, M. C.; Luhr, J. F.; Venzke, E. A.; Wunderman, R. L.

    2001-12-01

    The awesome power and intricate inner workings of volcanoes have made them a popular subject with scientists and the general public alike. About 1500 known volcanoes have been active on Earth during the Holocene, approximately 50 of which erupt per year. With so much activity occurring around the world, often in remote locations, it can be difficult to find up-to-date information about current volcanism from a reliable source. To satisfy the desire for timely volcano-related information the Smithsonian Institution and US Geological Survey combined their strengths to create the Weekly Volcanic Activity Report. The Smithsonian's Global Volcanism Program (GVP) has developed a network of correspondents while reporting worldwide volcanism for over 30 years in their monthly Bulletin of the Global Volcanism Network. The US Geological Survey's Volcano Hazards Program studies and monitors volcanoes in the United States and responds (upon invitation) to selected volcanic crises in other countries. The Weekly Volcanic Activity Report is one of the most popular sites on both organization's websites. The core of the Weekly Volcanic Activity Report is the brief summaries of current volcanic activity around the world. In addition to discussing various types of volcanism, the summaries also describe precursory activity (e.g. volcanic seismicity, deformation, and gas emissions), secondary activity (e.g. debris flows, mass wasting, and rockfalls), volcanic ash hazards to aviation, and preventative measures. The summaries are supplemented by links to definitions of technical terms found in the USGS photoglossary of volcano terms, links to information sources, and background information about reported volcanoes. The site also includes maps that highlight the location of reported volcanoes, an archive of weekly reports sorted by volcano and date, and links to commonly used acronyms. Since the Weekly Volcanic Activity Report's inception in November 2000, activity has been reported at

  8. Can free energy calculations be fast and accurate at the same time? Binding of low-affinity, non-peptide inhibitors to the SH2 domain of the src protein

    Science.gov (United States)

    Chipot, Christophe; Rozanska, Xavier; Dixit, Surjit B.

    2005-11-01

    The usefulness of free-energy calculations in non-academic environments, in general, and in the pharmaceutical industry, in particular, is a long-time debated issue, often considered from the angle of cost/performance criteria. In the context of the rational drug design of low-affinity, non-peptide inhibitors to the SH2 domain of the pp60src tyrosine kinase, the continuing difficulties encountered in an attempt to obtain accurate free-energy estimates are addressed. free-energy calculations can provide a convincing answer, assuming that two key-requirements are fulfilled: (i) thorough sampling of the configurational space is necessary to minimize the statistical error, hence raising the question: to which extent can we sacrifice the computational effort, yet without jeopardizing the precision of the free-energy calculation? (ii) the sensitivity of binding free-energies to the parameters utilized imposes an appropriate parametrization of the potential energy function, especially for non-peptide molecules that are usually poorly described by multipurpose macromolecular force fields. Employing the free-energy perturbation method, accurate ranking, within ±0.7 kcal/mol, is obtained in the case of four non-peptide mimes of a sequence recognized by the pp60src SH2 domain.

  9. A simple, fast, and accurate thermodynamic-based approach for transfer and prediction of gas chromatography retention times between columns and instruments Part III: Retention time prediction on target column.

    Science.gov (United States)

    Hou, Siyuan; Stevenson, Keisean A J M; Harynuk, James J

    2018-03-27

    This is the third part of a three-part series of papers. In Part I, we presented a method for determining the actual effective geometry of a reference column as well as the thermodynamic-based parameters of a set of probe compounds in an in-house mixture. Part II introduced an approach for estimating the actual effective geometry of a target column by collecting retention data of the same mixture of probe compounds on the target column and using their thermodynamic parameters, acquired on the reference column, as a bridge between both systems. Part III, presented here, demonstrates the retention time transfer and prediction from the reference column to the target column using experimental data for a separate mixture of compounds. To predict the retention time of a new compound, we first estimate its thermodynamic-based parameters on the reference column (using geometric parameters determined previously). The compound's retention time on a second column (of previously determined geometry) is then predicted. The models and the associated optimization algorithms were tested using simulated and experimental data. The accuracy of predicted retention times shows that the proposed approach is simple, fast, and accurate for retention time transfer and prediction between gas chromatography columns. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Screening of 485 Pesticide Residues in Fruits and Vegetables by Liquid Chromatography-Quadrupole-Time-of-Flight Mass Spectrometry Based on TOF Accurate Mass Database and QTOF Spectrum Library.

    Science.gov (United States)

    Pang, Guo-Fang; Fan, Chun-Lin; Chang, Qiao-Ying; Li, Jian-Xun; Kang, Jian; Lu, Mei-Ling

    2018-03-22

    This paper uses the LC-quadrupole-time-of-flight MS technique to evaluate the behavioral characteristics of MSof 485 pesticides under different conditions and has developed an accurate mass database and spectra library. A high-throughput screening and confirmation method has been developed for the 485 pesticides in fruits and vegetables. Through the optimization of parameters such as accurate mass number, time of retention window, ionization forms, etc., the method has improved the accuracy of pesticide screening, thus avoiding the occurrence of false-positive and false-negative results. The method features a full scan of fragments, with 80% of pesticide qualitative points over 10, which helps increase pesticide qualitative accuracy. The abundant differences of fragment categories help realize the effective separation and qualitative identification of isomer pesticides. Four different fruits and vegetables-apples, grapes, celery, and tomatoes-were chosen to evaluate the efficiency of the method at three fortification levels of 5, 10, and 20 μg/kg, and satisfactory results were obtained. With this method, a national survey of pesticide residues was conducted between 2012 and 2015 for 12 551 samples of 146 different fruits and vegetables collected from 638 sampling points in 284 counties across 31 provincial capitals/cities directly under the central government, which provided scientific data backup for ensuring pesticide residue safety of the fruits and vegetables consumed daily by the public. Meanwhile, the big data statistical analysis of the new technique also further proves it to be of high speed, high throughput, high accuracy, high reliability, and high informatization.

  11. Accurate Evaluation of Quantum Integrals

    Science.gov (United States)

    Galant, D. C.; Goorvitch, D.; Witteborn, Fred C. (Technical Monitor)

    1995-01-01

    Combining an appropriate finite difference method with Richardson's extrapolation results in a simple, highly accurate numerical method for solving a Schrodinger's equation. Important results are that error estimates are provided, and that one can extrapolate expectation values rather than the wavefunctions to obtain highly accurate expectation values. We discuss the eigenvalues, the error growth in repeated Richardson's extrapolation, and show that the expectation values calculated on a crude mesh can be extrapolated to obtain expectation values of high accuracy.

  12. Integrating field plots, lidar, and landsat time series to provide temporally consistent annual estimates of biomass from 1990 to present

    Science.gov (United States)

    Warren B. Cohen; Hans-Erik Andersen; Sean P. Healey; Gretchen G. Moisen; Todd A. Schroeder; Christopher W. Woodall; Grant M. Domke; Zhiqiang Yang; Robert E. Kennedy; Stephen V. Stehman; Curtis Woodcock; Jim Vogelmann; Zhe Zhu; Chengquan. Huang

    2015-01-01

    We are developing a system that provides temporally consistent biomass estimates for national greenhouse gas inventory reporting to the United Nations Framework Convention on Climate Change. Our model-assisted estimation framework relies on remote sensing to scale from plot measurements to lidar strip samples, to Landsat time series-based maps. As a demonstration, new...

  13. 25 CFR 26.30 - Does the Job Training Program provide part-time training or short-term training?

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Does the Job Training Program provide part-time training or short-term training? 26.30 Section 26.30 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Training Services § 26.30 Does the Job Training...

  14. One at a time: counting single-nanoparticle/electrode collisions for accurate particle sizing by overcoming the instability of gold nanoparticles under electrolytic conditions

    International Nuclear Information System (INIS)

    Qiu, Danfeng; Wang, Song; Zheng, Yuanqin; Deng, Zhaoxiang

    2013-01-01

    In response to an increasing demand for understanding electrochemical processes on the nanometer scale, it now becomes possible to monitor electron transfer reactions at the single-nanoparticle level, namely particle collision electrochemistry. This technique has great potential in the development of research tools towards single-particle electrocatalysis and selective and multiplexed particle sizing. However, one existing problem that may discourage these applications is the relatively weak colloidal stability of nanoparticles in an electrolytic solution. Here we report on a facile but efficient way to achieve a good stability of gold nanoparticles in an acidic media so that ‘zero-aggregation’ collisions can be achieved at a carbon ultramicroelectrode. This allows us to obtain anodic dissolution currents from individual nanoparticles in a ‘one particle at a time’ manner, based on which accurate particle sizing with a resolution of 1–2 nm can be achieved. Our work strongly suggests that to maintain a well dispersed nanoparticle solution during a particle impact electrochemical experiment is critically important for accurate particle sizing, as well as other applications that require information to be extracted from individual nanoparticles (not their aggregates). (paper)

  15. Accurate quantum chemical calculations

    Science.gov (United States)

    Bauschlicher, Charles W., Jr.; Langhoff, Stephen R.; Taylor, Peter R.

    1989-01-01

    An important goal of quantum chemical calculations is to provide an understanding of chemical bonding and molecular electronic structure. A second goal, the prediction of energy differences to chemical accuracy, has been much harder to attain. First, the computational resources required to achieve such accuracy are very large, and second, it is not straightforward to demonstrate that an apparently accurate result, in terms of agreement with experiment, does not result from a cancellation of errors. Recent advances in electronic structure methodology, coupled with the power of vector supercomputers, have made it possible to solve a number of electronic structure problems exactly using the full configuration interaction (FCI) method within a subspace of the complete Hilbert space. These exact results can be used to benchmark approximate techniques that are applicable to a wider range of chemical and physical problems. The methodology of many-electron quantum chemistry is reviewed. Methods are considered in detail for performing FCI calculations. The application of FCI methods to several three-electron problems in molecular physics are discussed. A number of benchmark applications of FCI wave functions are described. Atomic basis sets and the development of improved methods for handling very large basis sets are discussed: these are then applied to a number of chemical and spectroscopic problems; to transition metals; and to problems involving potential energy surfaces. Although the experiences described give considerable grounds for optimism about the general ability to perform accurate calculations, there are several problems that have proved less tractable, at least with current computer resources, and these and possible solutions are discussed.

  16. The Iowa new practice model: Advancing technician roles to increase pharmacists' time to provide patient care services.

    Science.gov (United States)

    Andreski, Michael; Myers, Megan; Gainer, Kate; Pudlo, Anthony

    Determine the effects of an 18-month pilot project using tech-check-tech in 7 community pharmacies on 1) rate of dispensing errors not identified during refill prescription final product verification; 2) pharmacist workday task composition; and 3) amount of patient care services provided and the reimbursement status of those services. Pretest-posttest quasi-experimental study where baseline and study periods were compared. Pharmacists and pharmacy technicians in 7 community pharmacies in Iowa. The outcome measures were 1) percentage of technician verified refill prescriptions where dispensing errors were not identified on final product verification; 2) percentage of time spent by pharmacists in dispensing, management, patient care, practice development, and other activities; 3) the number of pharmacist patient care services provided per pharmacist hours worked; and 4) percentage of time that technician product verification was used. There was no significant difference in overall errors (0.2729% vs. 0.5124%, P = 0.513), patient safety errors (0.0525% vs. 0.0651%, P = 0.837), or administrative errors (0.2204% vs. 0.4784%, P = 0.411). Pharmacist's time in dispensing significantly decreased (67.3% vs. 49.06%, P = 0.005), and time in direct patient care (19.96% vs. 34.72%, P = 0.003), increased significantly. Time in other activities did not significantly change. Reimbursable services per pharmacist hour (0.11 vs. 0.30, P = 0.129), did not significantly change. Non-reimbursable services increased significantly (2.77 vs. 4.80, P = 0.042). Total services significantly increased (2.88 vs. 5.16, P = 0.044). Pharmacy technician product verification of refill prescriptions preserved dispensing safety while significantly increasing the time spent in delivery of pharmacist provided patient care services. The total number of pharmacist services provided per hour also increased significantly, driven primarily by a significant increase in the number of non

  17. Power and type I error results for a bias-correction approach recently shown to provide accurate odds ratios of genetic variants for the secondary phenotypes associated with primary diseases.

    Science.gov (United States)

    Wang, Jian; Shete, Sanjay

    2011-11-01

    We recently proposed a bias correction approach to evaluate accurate estimation of the odds ratio (OR) of genetic variants associated with a secondary phenotype, in which the secondary phenotype is associated with the primary disease, based on the original case-control data collected for the purpose of studying the primary disease. As reported in this communication, we further investigated the type I error probabilities and powers of the proposed approach, and compared the results to those obtained from logistic regression analysis (with or without adjustment for the primary disease status). We performed a simulation study based on a frequency-matching case-control study with respect to the secondary phenotype of interest. We examined the empirical distribution of the natural logarithm of the corrected OR obtained from the bias correction approach and found it to be normally distributed under the null hypothesis. On the basis of the simulation study results, we found that the logistic regression approaches that adjust or do not adjust for the primary disease status had low power for detecting secondary phenotype associated variants and highly inflated type I error probabilities, whereas our approach was more powerful for identifying the SNP-secondary phenotype associations and had better-controlled type I error probabilities. © 2011 Wiley Periodicals, Inc.

  18. Time Accurate Unsteady Simulation of the Stall Inception Process in the Compression System of a US Army Helicopter Gas Turbine Engine

    National Research Council Canada - National Science Library

    Hathaway, Michael D; Herrick, Greg; Chen, Jenping; Webster, Robert

    2004-01-01

    .... Improved understanding of the stall inception process and how stall control technologies mitigate such will provide compressors with increased tolerance to stall, thereby expanding the operational...

  19. Barriers to Real-Time Medical Direction via Cellular Communication for Prehospital Emergency Care Providers in Gujarat, India.

    Science.gov (United States)

    Lindquist, Benjamin; Strehlow, Matthew C; Rao, G V Ramana; Newberry, Jennifer A

    2016-07-08

    Many low- and middle-income countries depend on emergency medical technicians (EMTs), nurses, midwives, and layperson community health workers with limited training to provide a majority of emergency medical, trauma, and obstetric care in the prehospital setting. To improve timely patient care and expand provider scope of practice, nations leverage cellular phones and call centers for real-time online medical direction. However, there exist several barriers to adequate communication that impact the provision of emergency care. We sought to identify obstacles in the cellular communication process among GVK Emergency Management and Research Institute (GVK EMRI) EMTs in Gujarat, India. A convenience sample of practicing EMTs in Gujarat, India were surveyed regarding the barriers to call initiation and completion. 108 EMTs completed the survey. Overall, ninety-seven (89.8%) EMTs responded that the most common reason they did not initiate a call with the call center physician was insufficient time. Forty-six (42%) EMTs reported that they were unable to call the physician one or more times during a typical workweek (approximately 5-6 twelve-hour shifts/week) due to their hands being occupied performing direct patient care. Fifty-eight (54%) EMTs reported that they were unable to reach the call center physician, despite attempts, at least once a week. This study identified multiple barriers to communication, including insufficient time to call for advice and inability to reach call center physicians. Identification of simple interventions and best practices may improve communication and ensure timely and appropriate prehospital care.

  20. Towards accurate emergency response behavior

    International Nuclear Information System (INIS)

    Sargent, T.O.

    1981-01-01

    Nuclear reactor operator emergency response behavior has persisted as a training problem through lack of information. The industry needs an accurate definition of operator behavior in adverse stress conditions, and training methods which will produce the desired behavior. Newly assembled information from fifty years of research into human behavior in both high and low stress provides a more accurate definition of appropriate operator response, and supports training methods which will produce the needed control room behavior. The research indicates that operator response in emergencies is divided into two modes, conditioned behavior and knowledge based behavior. Methods which assure accurate conditioned behavior, and provide for the recovery of knowledge based behavior, are described in detail

  1. Leisure activities are linked to mental health benefits by providing time structure: comparing employed, unemployed and homemakers.

    Science.gov (United States)

    Goodman, William K; Geiger, Ashley M; Wolf, Jutta M

    2017-01-01

    Unemployment has consistently been linked to negative mental health outcomes, emphasising the need to characterise the underlying mechanisms. The current study aimed at testing whether compared with other employment groups, fewer leisure activities observed in unemployment may contribute to elevated risk for negative mental health via loss of time structure. Depressive symptoms (Center for Epidemiologic Studies Depression), leisure activities (exercise, self-focused, social), and time structure (Time Structure Questionnaire (TSQ)) were assessed cross-sectionally in 406 participants (unemployed=155, employed=140, homemakers=111) recruited through Amazon Mechanical Turk. Controlling for gender and age, structural equation modelling revealed time structure partially (employed, homemakers) and fully (unemployed) mediated the relationship between leisure activities and depressive symptoms. With the exception of differential effects for structured routines, all other TSQ factors (sense of purpose, present orientation, effective organisation and persistence) contributed significantly to all models. These findings support the idea that especially for the unemployed, leisure activities impose their mental health benefits through increasing individuals' perception of spending their time effectively. Social leisure activities that provide a sense of daily structure may thereby be a particularly promising low-cost intervention to improve mental health in this population. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  2. Groundwater residence time : tell me who you are and I will tell which information you may provide

    Science.gov (United States)

    Aquilina, Luc; Labasque, Thierry; Kolbe, Tamara; Marçais, Jean; Leray, Sarah; Abbott, Ben; de Dreuzy, Jean-Raynald

    2016-04-01

    Groundwater residence-time or ages have been widely used in hydrogeology during the last decades. Following tritium measurements, anthropogenic gases (CFC, SF6, 35Kr) have been developed. They provide information at the aquifer scale on long residence times. They complement the more localized data obtained from sparse boreholes with hydraulic and geophysical methods. Anthropogenic tracer concentrations are most generally considered as "Groundwater ages" using a piston flow model providing an order of magnitude for the residence time. More advanced information can however be derived from the combined analysis of the tracer concentrations. For example, the residence time distribution over the last 50 years can be well approached by the concentration of two sufficient different anthropogenic tracers in the group (CFC, SF6, 35Kr), i.e. tracers whose anthropogenic chronicles are sufficiently different. And, with additional constrains on geological and hydraulic properties, groundwater ages contribute to characterize the aquifer structures and the groundwater resources. Complex geological environments also include old groundwater bodies in extremely confined aquifer sections. In such cases, various tracers are related to highly different processes. CFCs can be taken as a marker of modern contamination to track exchanges between shallower and deeper aquifers, leakage processes, and modification of circulations linked to recent anthropogenic changes. 14C or 36Cl can be used to evidence much older processes but have to be related to the history of the chemical element itself. Numerous field studies in fact demonstrate the broad-range extent of the residence time distribution spanning in some cases several orders of magnitude. Flow and transport models in heterogeneous structures confirm such wide residence times and help to characterize their distribution. Residence times also serve as a privileged interface to the fate of some contaminants in aquifers or to trace

  3. Influencing Anesthesia Provider Behavior Using Anesthesia Information Management System Data for Near Real-Time Alerts and Post Hoc Reports.

    Science.gov (United States)

    Epstein, Richard H; Dexter, Franklin; Patel, Neil

    2015-09-01

    In this review article, we address issues related to using data from anesthesia information management systems (AIMS) to deliver near real-time alerts via AIMS workstation popups and/or alphanumeric pagers and post hoc reports via e-mail. We focus on reports and alerts for influencing the behavior of anesthesia providers (i.e., anesthesiologists, anesthesia residents, and nurse anesthetists). Multiple studies have shown that anesthesia clinical decision support (CDS) improves adherence to protocols and increases financial performance through facilitation of billing, regulatory, and compliance documentation; however, improved clinical outcomes have not been demonstrated. We inform developers and users of feedback systems about the multitude of concerns to consider during development and implementation of CDS to increase its effectiveness and to mitigate its potentially disruptive aspects. We discuss the timing and modalities used to deliver messages, implications of outlier-only versus individualized feedback, the need to consider possible unintended consequences of such feedback, regulations, sustainability, and portability among systems. We discuss statistical issues related to the appropriate evaluation of CDS efficacy. We provide a systematic review of the published literature (indexed in PubMed) of anesthesia CDS and offer 2 case studies of CDS interventions using AIMS data from our own institution illustrating the salient points. Because of the considerable expense and complexity of maintaining near real-time CDS systems, as compared with providing individual reports via e-mail after the fact, we suggest that if the same goal can be accomplished via delayed reporting versus immediate feedback, the former approach is preferable. Nevertheless, some processes require near real-time alerts to produce the desired improvement. Post hoc e-mail reporting from enterprise-wide electronic health record systems is straightforward and can be accomplished using system

  4. Measurement and valuation of health providers' time for the management of childhood pneumonia in rural Malawi: an empirical study.

    Science.gov (United States)

    Bozzani, Fiammetta Maria; Arnold, Matthias; Colbourn, Timothy; Lufesi, Norman; Nambiar, Bejoy; Masache, Gibson; Skordis-Worrall, Jolene

    2016-07-28

    Human resources are a major cost driver in childhood pneumonia case management. Introduction of 13-valent pneumococcal conjugate vaccine (PCV-13) in Malawi can lead to savings on staff time and salaries due to reductions in pneumonia cases requiring admission. Reliable estimates of human resource costs are vital for use in economic evaluations of PCV-13 introduction. Twenty-eight severe and twenty-four very severe pneumonia inpatients under the age of five were tracked from admission to discharge by paediatric ward staff using self-administered timesheets at Mchinji District Hospital between June and August 2012. All activities performed and the time spent on each activity were recorded. A monetary value was assigned to the time by allocating a corresponding percentage of the health workers' salary. All costs are reported in 2012 US$. A total of 1,017 entries, grouped according to 22 different activity labels, were recorded during the observation period. On average, 99 min (standard deviation, SD = 46) were spent on each admission: 93 (SD = 38) for severe and 106 (SD = 55) for very severe cases. Approximately 40 % of activities involved monitoring and stabilization, including administering non-drug therapies such as oxygen. A further 35 % of the time was spent on injecting antibiotics. Nurses provided 60 % of the total time spent on pneumonia admissions, clinicians 25 % and support staff 15 %. Human resource costs were approximately US$ 2 per bed-day and, on average, US$ 29.5 per severe pneumonia admission and US$ 37.7 per very severe admission. Self-reporting was successfully used in this context to generate reliable estimates of human resource time and costs of childhood pneumonia treatment. Assuming vaccine efficacy of 41 % and 90 % coverage, PCV-13 introduction in Malawi can save over US$ 2 million per year in staff costs alone.

  5. Comparison of in-and outpatients protocols for providence night time only bracing in AIS patients -- compliance and satisfaction

    DEFF Research Database (Denmark)

    Al-Aubaidi, Zaid Tj; Tropp, Hans; Pedersen, Niels W

    2013-01-01

    BACKGROUND: Skeletally immature patients diagnosed with adolescent idiopathic scoliosis (AIS) and a Cobb angle above 25degrees is usually treated with a brace. Standard protocols in many centers include hospitalisation for a few days for the purpose of brace adaptation and fitting. The aim...... of this study is to compare compliance and satisfaction in hospitalization and out patient clinic protocols, at the initiation phase of brace treatment.Materials and methodsTwenty-four consecutive patients with AIS were initiated with the Providence night time only brace at our department between October 2008...

  6. Primary Care Providers' Opening of Time-Sensitive Alerts Sent to Commercial Electronic Health Record InBaskets.

    Science.gov (United States)

    Cutrona, Sarah L; Fouayzi, Hassan; Burns, Laura; Sadasivam, Rajani S; Mazor, Kathleen M; Gurwitz, Jerry H; Garber, Lawrence; Sundaresan, Devi; Houston, Thomas K; Field, Terry S

    2017-11-01

    Time-sensitive alerts are among the many types of clinical notifications delivered to physicians' secure InBaskets within commercial electronic health records (EHRs). A delayed alert review can impact patient safety and compromise care. To characterize factors associated with opening of non-interruptive time-sensitive alerts delivered into primary care provider (PCP) InBaskets. We analyzed data for 799 automated alerts. Alerts highlighted actionable medication concerns for older patients post-hospital discharge (2010-2011). These were study-generated alerts sent 3 days post-discharge to InBaskets for 75 PCPs across a multisite healthcare system, and represent a subset of all urgent InBasket notifications. Using EHR access and audit logs to track alert opening, we performed bivariate and multivariate analyses calculating associations between patient characteristics, provider characteristics, contextual factors at the time of alert delivery (number of InBasket notifications, weekday), and alert opening within 24 h. At the time of alert delivery, the PCPs had a median of 69 InBasket notifications and had received a median of 379.8 notifications (IQR 295.0, 492.0) over the prior 7 days. Of the 799 alerts, 47.1% were opened within 24 h. Patients with longer hospital stays (>4 days) were marginally more likely to have alerts opened (OR 1.48 [95% CI 1.00-2.19]). Alerts delivered to PCPs whose InBaskets had a higher number of notifications at the time of alert delivery were significantly less likely to be opened within 24 h (top quartile >157 notifications: OR 0.34 [95% CI 0.18-0.61]; reference bottom quartile ≤42). Alerts delivered on Saturdays were also less likely to be opened within 24 h (OR 0.18 [CI 0.08-0.39]). The number of total InBasket notifications and weekend delivery may impact the opening of time-sensitive EHR alerts. Further study is needed to support safe and effective approaches to care team management of InBasket notifications.

  7. Endovascular aneurysm repair simulation can lead to decreased fluoroscopy time and accurately delineate the proximal seal zone.

    Science.gov (United States)

    Kim, Ann H; Kendrick, Daniel E; Moorehead, Pamela A; Nagavalli, Anil; Miller, Claire P; Liu, Nathaniel T; Wang, John C; Kashyap, Vikram S

    2016-07-01

    The use of simulators for endovascular aneurysm repair (EVAR) is not widespread. We examined whether simulation could improve procedural variables, including operative time and optimizing proximal seal. For the latter, we compared suprarenal vs infrarenal fixation endografts, right femoral vs left femoral main body access, and increasing angulation of the proximal aortic neck. Computed tomography angiography was obtained from 18 patients who underwent EVAR at a single institution. Patient cases were uploaded to the ANGIO Mentor endovascular simulator (Simbionix, Cleveland, Ohio) allowing for three-dimensional reconstruction and adapted for simulation with suprarenal fixation (Endurant II; Medtronic Inc, Minneapolis, Minn) and infrarenal fixation (C3; W. L. Gore & Associates Inc, Newark, Del) deployment systems. Three EVAR novices and three experienced surgeons performed 18 cases from each side with each device in randomized order (n = 72 simulations/participant). The cases were stratified into three groups according to the degree of infrarenal angulation: 0° to 20°, 21° to 40°, and 41° to 66°. Statistical analysis used paired t-test and one-way analysis of variance. Mean fluoroscopy time for participants decreased by 48.6% (P time decreased by 33.8% (P zone coverage in highly angulated aortic necks was significantly decreased. The infrarenal device resulted in mean aortic neck zone coverage of 91.9%, 89.4%, and 75.4% (P zone coverage. The side of femoral access for the main body did not influence proximal seal zone coverage regardless of infrarenal angulation. Simulation of EVAR leads to decreased fluoroscopy times for novice and experienced operators. Side of femoral access did not affect precision of proximal endograft landing. The angulated aortic neck leads to decreased proximal seal zone coverage regardless of infrarenal or suprarenal fixation devices. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  8. Time-driven activity-based costing: a driver for provider engagement in costing activities and redesign initiatives.

    Science.gov (United States)

    McLaughlin, Nancy; Burke, Michael A; Setlur, Nisheeta P; Niedzwiecki, Douglas R; Kaplan, Alan L; Saigal, Christopher; Mahajan, Aman; Martin, Neil A; Kaplan, Robert S

    2014-11-01

    To date, health care providers have devoted significant efforts to improve performance regarding patient safety and quality of care. To address the lagging involvement of health care providers in the cost component of the value equation, UCLA Health piloted the implementation of time-driven activity-based costing (TDABC). Here, the authors describe the implementation experiment, share lessons learned across the care continuum, and report how TDABC has actively engaged health care providers in costing activities and care redesign. After the selection of pilots in neurosurgery and urology and the creation of the TDABC team, multidisciplinary process mapping sessions, capacity-cost calculations, and model integration were coordinated and offered to engage care providers at each phase. Reviewing the maps for the entire episode of care, varying types of personnel involved in the delivery of care were noted: 63 for the neurosurgery pilot and 61 for the urology pilot. The average cost capacities for care coordinators, nurses, residents, and faculty were $0.70 (range $0.63-$0.75), $1.55 (range $1.28-$2.04), $0.58 (range $0.56-$0.62), and $3.54 (range $2.29-$4.52), across both pilots. After calculating the costs for material, equipment, and space, the TDABC model enabled the linking of a specific step of the care cycle (who performed the step and its duration) and its associated costs. Both pilots identified important opportunities to redesign care delivery in a costconscious fashion. The experimentation and implementation phases of the TDABC model have succeeded in engaging health care providers in process assessment and costing activities. The TDABC model proved to be a catalyzing agent for cost-conscious care redesign.

  9. The Tehran Older Adults’ Leisure Time and Physical Activity With Emphesize of Sport Equipments Provided by Municipality in 2010

    Directory of Open Access Journals (Sweden)

    Mahboubeh Chamanpira

    2014-10-01

    Full Text Available Objectives: The purpose of this research is to evaluate the quality of the older adults’ leisure time in Tehran focused on their physical activity and their satisfaction with outdoor sport facilities provided in the parks by municipality. Methods & Materials: The type of research is descriptive in which Tehran is divided into 5 (geographical districts. Through cluster sampling method, 366 individuals has been randomly selected out of 701300 people as Tehran elderly population. The information gathering tool is a questionnaire made by the researcher. Its validity and reliability was measured by experts and Cronbach’s alpha 0.80. Pearson’s r correlations were conducted in order to determine whether significant correlations exist between variables. All statistical analysis were done using SPSS 13 software and alpha level was set at <0.05 Results: findings show that about 74% of the elderly do exercise, most of which is walking. It has been revealed through this research that 59.7% are moderate with the quality of their leisure time. In addition, 48.2% does not use the sports equipments in the parks and 41.7% think that body-building equipment in the parks highly or absolutely highly appropriate for the elderly. There is a meaningful correlation between age and duration of leisure time (P<0.01.Whereas, the correlation between age and satisfaction with facilities is not meaningful (P≤0.05. Furthermore, there are also meaningful correlation between gender and the degree of satisfaction. Conclusion: According to findings of this research, the majority of elder were satisfied with their liesure time at moderately level. Doing physical activity have a significant role in their satisfaction of leisure time. Existing of appropriate sports equipments in parks encourage them to practice physical activities. As a result, the extension and development of these facilities are recommended.

  10. A Classical Based Derivation of Time Dilation Providing First Order Accuracy to Schwarzschild's Solution of Einstein's Field Equations

    Science.gov (United States)

    Austin, Rickey W.

    In Einstein's theory of Special Relativity (SR), one method to derive relativistic kinetic energy is via applying the classical work-energy theorem to relativistic momentum. This approach starts with a classical based work-energy theorem and applies SR's momentum to the derivation. One outcome of this derivation is relativistic kinetic energy. From this derivation, it is rather straight forward to form a kinetic energy based time dilation function. In the derivation of General Relativity a common approach is to bypass classical laws as a starting point. Instead a rigorous development of differential geometry and Riemannian space is constructed, from which classical based laws are derived. This is in contrast to SR's approach of starting with classical laws and applying the consequences of the universal speed of light by all observers. A possible method to derive time dilation due to Newtonian gravitational potential energy (NGPE) is to apply SR's approach to deriving relativistic kinetic energy. It will be shown this method gives a first order accuracy compared to Schwarzschild's metric. The SR's kinetic energy and the newly derived NGPE derivation are combined to form a Riemannian metric based on these two energies. A geodesic is derived and calculations compared to Schwarzschild's geodesic for an orbiting test mass about a central, non-rotating, non-charged massive body. The new metric results in high accuracy calculations when compared to Einsteins General Relativity's prediction. The new method provides a candidate approach for starting with classical laws and deriving General Relativity effects. This approach mimics SR's method of starting with classical mechanics when deriving relativistic equations. As a compliment to introducing General Relativity, it provides a plausible scaffolding method from classical physics when teaching introductory General Relativity. A straight forward path from classical laws to General Relativity will be derived. This derivation

  11. First Time Rapid and Accurate Detection of Massive Number of Metal Absorption Lines in the Early Universe Using Deep Neural Network

    Science.gov (United States)

    Zhao, Yinan; Ge, Jian; Yuan, Xiaoyong; Li, Xiaolin; Zhao, Tiffany; Wang, Cindy

    2018-01-01

    Metal absorption line systems in the distant quasar spectra have been used as one of the most powerful tools to probe gas content in the early Universe. The MgII λλ 2796, 2803 doublet is one of the most popular metal absorption lines and has been used to trace gas and global star formation at redshifts between ~0.5 to 2.5. In the past, machine learning algorithms have been used to detect absorption lines systems in the large sky survey, such as Principle Component Analysis, Gaussian Process and decision tree, but the overall detection process is not only complicated, but also time consuming. It usually takes a few months to go through the entire quasar spectral dataset from each of the Sloan Digital Sky Survey (SDSS) data release. In this work, we applied the deep neural network, or “ deep learning” algorithms, in the most recently SDSS DR14 quasar spectra and were able to randomly search 20000 quasar spectra and detect 2887 strong Mg II absorption features in just 9 seconds. Our detection algorithms were verified with previously released DR12 and DR7 data and published Mg II catalog and the detection accuracy is 90%. This is the first time that deep neural network has demonstrated its promising power in both speed and accuracy in replacing tedious, repetitive human work in searching for narrow absorption patterns in a big dataset. We will present our detection algorithms and also statistical results of the newly detected Mg II absorption lines.

  12. The accurate particle tracer code

    Science.gov (United States)

    Wang, Yulei; Liu, Jian; Qin, Hong; Yu, Zhi; Yao, Yicun

    2017-11-01

    The Accurate Particle Tracer (APT) code is designed for systematic large-scale applications of geometric algorithms for particle dynamical simulations. Based on a large variety of advanced geometric algorithms, APT possesses long-term numerical accuracy and stability, which are critical for solving multi-scale and nonlinear problems. To provide a flexible and convenient I/O interface, the libraries of Lua and Hdf5 are used. Following a three-step procedure, users can efficiently extend the libraries of electromagnetic configurations, external non-electromagnetic forces, particle pushers, and initialization approaches by use of the extendible module. APT has been used in simulations of key physical problems, such as runaway electrons in tokamaks and energetic particles in Van Allen belt. As an important realization, the APT-SW version has been successfully distributed on the world's fastest computer, the Sunway TaihuLight supercomputer, by supporting master-slave architecture of Sunway many-core processors. Based on large-scale simulations of a runaway beam under parameters of the ITER tokamak, it is revealed that the magnetic ripple field can disperse the pitch-angle distribution significantly and improve the confinement of energetic runaway beam on the same time.

  13. Providing critical laboratory results on time, every time to help reduce emergency department length of stay: how our laboratory achieved a Six Sigma level of performance.

    Science.gov (United States)

    Blick, Kenneth E

    2013-08-01

    To develop a fully automated core laboratory, handling samples on a "first in, first out" real-time basis with Lean/Six Sigma management tools. Our primary goal was to provide services to critical care areas, eliminating turnaround time outlier percentage (TAT-OP) as a factor in patient length of stay (LOS). A secondary goal was to achieve a better laboratory return on investment. In 2011, we reached our primary goal when we calculated the TAT-OP distribution and found we had achieved a Six Sigma level of performance, ensuring that our laboratory service can be essentially eliminated as a factor in emergency department patient LOS. We also measured return on investment, showing a productivity improvement of 35%, keeping pace with our increased testing volume. As a result of our Lean process improvements and Six Sigma initiatives, in part through (1) strategic deployment of point-of-care testing and (2) core laboratory total automation with robotics, middleware, and expert system technology, physicians and nurses at the Oklahoma University Medical Center can more effectively deliver lifesaving health care using evidence-based protocols that depend heavily on "on time, every time" laboratory services.

  14. Spectrally accurate contour dynamics

    International Nuclear Information System (INIS)

    Van Buskirk, R.D.; Marcus, P.S.

    1994-01-01

    We present an exponentially accurate boundary integral method for calculation the equilibria and dynamics of piece-wise constant distributions of potential vorticity. The method represents contours of potential vorticity as a spectral sum and solves the Biot-Savart equation for the velocity by spectrally evaluating a desingularized contour integral. We use the technique in both an initial-value code and a newton continuation method. Our methods are tested by comparing the numerical solutions with known analytic results, and it is shown that for the same amount of computational work our spectral methods are more accurate than other contour dynamics methods currently in use

  15. Compressed sensing real-time cine cardiovascular magnetic resonance: accurate assessment of left ventricular function in a single-breath-hold.

    Science.gov (United States)

    Kido, Tomoyuki; Kido, Teruhito; Nakamura, Masashi; Watanabe, Kouki; Schmidt, Michaela; Forman, Christoph; Mochizuki, Teruhito

    2016-08-24

    Cardiovascular cine magnetic resonance (CMR) accelerated by compressed sensing (CS) is used to assess left ventricular (LV) function. However, it is difficult for prospective CS cine CMR to capture the complete end-diastolic phase, which can lead to underestimation of the end-diastolic volume (EDV), stroke volume (SV), and ejection fraction (EF), compared to retrospective standard cine CMR. This prospective study aimed to evaluate the diagnostic quality and accuracy of single-breath-hold full cardiac cycle CS cine CMR, acquired over two heart beats, to quantify LV volume in comparison to multi-breath-hold standard cine CMR. Eighty-one participants underwent standard segmented breath-hold cine and CS real-time cine CMR examinations to obtain a stack of eight contiguous short-axis images with same high spatial (1.7 × 1.7 mm(2)) and temporal resolution (41 ms). Two radiologists independently performed qualitative analysis of image quality (score, 1 [i.e., "nondiagnostic"] to 5 [i.e., "excellent"]) and quantitative analysis of the LV volume measurements. The total examination time was 113 ± 7 s for standard cine CMR and 24 ± 4 s for CS cine CMR (p cine image quality was slightly lower than standard cine (4.8 ± 0.5 for standard vs. 4.4 ± 0.5 for CS; p cine were above 4 (i.e., good). No significant differences existed between standard and CS cine MR for all quantitative LV measurements. The mean differences with 95 % confidence interval (CI), based on Bland-Altman analysis, were 1.3 mL (95 % CI, -14.6 - 17.2) for LV end-diastolic volume, 0.2 mL (95 % CI, -9.8 to10.3) for LV end-systolic volume, 1.1 mL (95 % CI, -10.5 to 12.7) for LV stroke volume, 1.0 g (95 % CI, -11.2 to 13.3) for LV mass, and 0.4 % (95 % CI, -4.8 - 5.6) for LV ejection fraction. The interobserver and intraobserver variability for CS cine MR ranged from -4.8 - 1.6 % and from -7.3 - 9.3 %, respectively, with slopes of the regressions ranging 0.88-1.0 and 0

  16. Ct shift: A novel and accurate real-time PCR quantification model for direct comparison of different nucleic acid sequences and its application for transposon quantifications.

    Science.gov (United States)

    Kolacsek, Orsolya; Pergel, Enikő; Varga, Nóra; Apáti, Ágota; Orbán, Tamás I

    2017-01-20

    There are numerous applications of quantitative PCR for both diagnostic and basic research. As in many other techniques the basis of quantification is that comparisons are made between different (unknown and known or reference) specimens of the same entity. When the aim is to compare real quantities of different species in samples, one cannot escape their separate precise absolute quantification. We have established a simple and reliable method for this purpose (Ct shift method) which combines the absolute and the relative approach. It requires a plasmid standard containing both sequences of amplicons to be compared (e.g. the target of interest and the endogenous control). It can serve as a reference sample with equal copies of templates for both targets. Using the ΔΔCt formula we can quantify the exact ratio of the two templates in each unknown sample. The Ct shift method has been successfully applied for transposon gene copy measurements, as well as for comparison of different mRNAs in cDNA samples. This study provides the proof of concept and introduces some potential applications of the method; the absolute nature of results even without the need for real reference samples can contribute to the universality of the method and comparability of different studies. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Accurate detection and quantification of the fish viral hemorrhagic Septicemia virus (VHSv with a two-color fluorometric real-time PCR assay.

    Directory of Open Access Journals (Sweden)

    Lindsey R Pierce

    Full Text Available Viral Hemorrhagic Septicemia virus (VHSv is one of the world's most serious fish pathogens, infecting >80 marine, freshwater, and estuarine fish species from Eurasia and North America. A novel and especially virulent strain - IVb - appeared in the Great Lakes in 2003, has killed many game fish species in a series of outbreaks in subsequent years, and shut down interstate transport of baitfish. Cell culture is the diagnostic method approved by the USDA-APHIS, which takes a month or longer, lacks sensitivity, and does not quantify the amount of virus. We thus present a novel, easy, rapid, and highly sensitive real-time quantitative reverse transcription PCR (qRT-PCR assay that incorporates synthetic competitive template internal standards for quality control to circumvent false negative results. Results demonstrate high signal-to-analyte response (slope = 1.00±0.02 and a linear dynamic range that spans seven orders of magnitude (R(2 = 0.99, ranging from 6 to 6,000,000 molecules. Infected fishes are found to harbor levels of virus that range to 1,200,000 VHSv molecules/10(6 actb1 molecules with 1,000 being a rough cut-off for clinical signs of disease. This new assay is rapid, inexpensive, and has significantly greater accuracy than other published qRT-PCR tests and traditional cell culture diagnostics.

  18. Accurate detection and quantification of the fish viral hemorrhagic Septicemia virus (VHSv) with a two-color fluorometric real-time PCR assay.

    Science.gov (United States)

    Pierce, Lindsey R; Willey, James C; Palsule, Vrushalee V; Yeo, Jiyoun; Shepherd, Brian S; Crawford, Erin L; Stepien, Carol A

    2013-01-01

    Viral Hemorrhagic Septicemia virus (VHSv) is one of the world's most serious fish pathogens, infecting >80 marine, freshwater, and estuarine fish species from Eurasia and North America. A novel and especially virulent strain - IVb - appeared in the Great Lakes in 2003, has killed many game fish species in a series of outbreaks in subsequent years, and shut down interstate transport of baitfish. Cell culture is the diagnostic method approved by the USDA-APHIS, which takes a month or longer, lacks sensitivity, and does not quantify the amount of virus. We thus present a novel, easy, rapid, and highly sensitive real-time quantitative reverse transcription PCR (qRT-PCR) assay that incorporates synthetic competitive template internal standards for quality control to circumvent false negative results. Results demonstrate high signal-to-analyte response (slope = 1.00±0.02) and a linear dynamic range that spans seven orders of magnitude (R(2) = 0.99), ranging from 6 to 6,000,000 molecules. Infected fishes are found to harbor levels of virus that range to 1,200,000 VHSv molecules/10(6) actb1 molecules with 1,000 being a rough cut-off for clinical signs of disease. This new assay is rapid, inexpensive, and has significantly greater accuracy than other published qRT-PCR tests and traditional cell culture diagnostics.

  19. Rapid and Accurate Detection of Bacteriophage Activity against Escherichia coli O157:H7 by Propidium Monoazide Real-Time PCR

    Directory of Open Access Journals (Sweden)

    Hui Liu

    2014-01-01

    Full Text Available Conventional methods to determine the efficacy of bacteriophage (phage for biocontrol of E. coli require several days, due to the need to culture bacteria. Furthermore, cell surface-attached phage particles may lyse bacterial cells during experiments, leading to an overestimation of phage activity. DNA-based real-time quantitative polymerase chain reaction (qPCR is a fast, sensitive, and highly specific means of enumerating pathogens. However, qPCR may underestimate phage activity due to its inability to distinguish viable from nonviable cells. In this study, we evaluated the suitability of propidium monoazide (PMA, a microbial membrane-impermeable dye that inhibits amplification of extracellular DNA and DNA within dead or membrane-compromised cells as a means of using qPCR to identify only intact E. coli cells that survive phage exposure. Escherichia coli O157:H7 strain R508N and 4 phages (T5-like, T1-like, T4-like, and O1-like were studied. Results compared PMA-qPCR and direct plating and confirmed that PMA could successfully inhibit amplification of DNA from compromised/damaged cells E. coli O157:H7. Compared to PMA-qPCR, direct plating overestimated (P < 0.01 phage efficacy as cell surface-attached phage particles lysed E. coli O157:H7 during the plating process. Treatment of samples with PMA in combination with qPCR can therefore be considered beneficial when assessing the efficacy of bacteriophage for biocontrol of E. coli O157:H7.

  20. Selection of Suitable Internal Control Genes for Accurate Normalization of Real-Time Quantitative PCR Data of Buffalo (Bubalus bubalis) Blastocysts Produced by SCNT and IVF.

    Science.gov (United States)

    Sood, Tanushri Jerath; Lagah, Swati Viviyan; Sharma, Ankita; Singla, Suresh Kumar; Mukesh, Manishi; Chauhan, Manmohan Singh; Manik, Radheysham; Palta, Prabhat

    2017-10-01

    We evaluated the suitability of 10 candidate internal control genes (ICGs), belonging to different functional classes, namely ACTB, EEF1A1, GAPDH, HPRT1, HMBS, RPS15, RPS18, RPS23, SDHA, and UBC for normalizing the real-time quantitative polymerase chain reaction (qPCR) data of blastocyst-stage buffalo embryos produced by hand-made cloning and in vitro fertilization (IVF). Total RNA was isolated from three pools, each of cloned and IVF blastocysts (n = 50/pool) for cDNA synthesis. Two different statistical algorithms geNorm and NormFinder were used for evaluating the stability of these genes. Based on gene stability measure (M value) and pairwise variation (V value), calculated by geNorm analysis, the most stable ICGs were RPS15, HPRT1, and ACTB for cloned blastocysts, HMBS, UBC, and HPRT1 for IVF blastocysts and RPS15, GAPDH, and HPRT1 for both the embryo types analyzed together. RPS18 was the least stable gene for both cloned and IVF blastocysts. Following NormFinder analysis, the order of stability was RPS15 = HPRT1>GAPDH for cloned blastocysts, HMBS = UBC>RPS23 for IVF blastocysts, and HPRT1>GAPDH>RPS15 for cloned and IVF blastocysts together. These results suggest that despite overlapping of the three most stable ICGs between cloned and IVF blastocysts, the panel of ICGs selected for normalization of qPCR data of cloned and IVF blastocyst-stage embryos should be different.

  1. Seven novel probe systems for real-time PCR provide absolute single-base discrimination, higher signaling, and generic components.

    Science.gov (United States)

    Murray, James L; Hu, Peixu; Shafer, David A

    2014-11-01

    We have developed novel probe systems for real-time PCR that provide higher specificity, greater sensitivity, and lower cost relative to dual-labeled probes. The seven DNA Detection Switch (DDS)-probe systems reported here employ two interacting polynucleotide components: a fluorescently labeled probe and a quencher antiprobe. High-fidelity detection is achieved with three DDS designs: two internal probes (internal DDS and Flip probes) and a primer probe (ZIPR probe), wherein each probe is combined with a carefully engineered, slightly mismatched, error-checking antiprobe. The antiprobe blocks off-target detection over a wide range of temperatures and facilitates multiplexing. Other designs (Universal probe, Half-Universal probe, and MacMan probe) use generic components that enable low-cost detection. Finally, single-molecule G-Force probes employ guanine-mediated fluorescent quenching by forming a hairpin between adjacent C-rich and G-rich sequences. Examples provided show how these probe technologies discriminate drug-resistant Mycobacterium tuberculosis mutants, Escherichia coli O157:H7, oncogenic EGFR deletion mutations, hepatitis B virus, influenza A/B strains, and single-nucleotide polymorphisms in the human VKORC1 gene. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  2. A system for accurate and automated injection of hyperpolarized substrate with minimal dead time and scalable volumes over a large range

    Science.gov (United States)

    Reynolds, Steven; Bucur, Adriana; Port, Michael; Alizadeh, Tooba; Kazan, Samira M.; Tozer, Gillian M.; Paley, Martyn N. J.

    2014-02-01

    Over recent years hyperpolarization by dissolution dynamic nuclear polarization has become an established technique for studying metabolism in vivo in animal models. Temporal signal plots obtained from the injected metabolite and daughter products, e.g. pyruvate and lactate, can be fitted to compartmental models to estimate kinetic rate constants. Modeling and physiological parameter estimation can be made more robust by consistent and reproducible injections through automation. An injection system previously developed by us was limited in the injectable volume to between 0.6 and 2.4 ml and injection was delayed due to a required syringe filling step. An improved MR-compatible injector system has been developed that measures the pH of injected substrate, uses flow control to reduce dead volume within the injection cannula and can be operated over a larger volume range. The delay time to injection has been minimized by removing the syringe filling step by use of a peristaltic pump. For 100 μl to 10.000 ml, the volume range typically used for mice to rabbits, the average delivered volume was 97.8% of the demand volume. The standard deviation of delivered volumes was 7 μl for 100 μl and 20 μl for 10.000 ml demand volumes (mean S.D. was 9 ul in this range). In three repeat injections through a fixed 0.96 mm O.D. tube the coefficient of variation for the area under the curve was 2%. For in vivo injections of hyperpolarized pyruvate in tumor-bearing rats, signal was first detected in the input femoral vein cannula at 3-4 s post-injection trigger signal and at 9-12 s in tumor tissue. The pH of the injected pyruvate was 7.1 ± 0.3 (mean ± S.D., n = 10). For small injection volumes, e.g. less than 100 μl, the internal diameter of the tubing contained within the peristaltic pump could be reduced to improve accuracy. Larger injection volumes are limited only by the size of the receiving vessel connected to the pump.

  3. High-resolution, time-resolved MRA provides superior definition of lower-extremity arterial segments compared to 2D time-of-flight imaging.

    Science.gov (United States)

    Thornton, F J; Du, J; Suleiman, S A; Dieter, R; Tefera, G; Pillai, K R; Korosec, F R; Mistretta, C A; Grist, T M

    2006-08-01

    To evaluate a novel time-resolved contrast-enhanced (CE) projection reconstruction (PR) magnetic resonance angiography (MRA) method for identifying potential bypass graft target vessels in patients with Class II-IV peripheral vascular disease. Twenty patients (M:F = 15:5, mean age = 58 years, range = 48-83 years), were recruited from routine MRA referrals. All imaging was performed on a 1.5 T MRI system with fast gradients (Signa LX; GE Healthcare, Waukesha, WI). Images were acquired with a novel technique that combined undersampled PR with a time-resolved acquisition to yield an MRA method with high temporal and spatial resolution. The method is called PR hyper time-resolved imaging of contrast kinetics (PR-hyperTRICKS). Quantitative and qualitative analyses were used to compare two-dimensional (2D) time-of-flight (TOF) and PR-hyperTRICKS in 13 arterial segments per lower extremity. Statistical analysis was performed with the Wilcoxon signed-rank test. Fifteen percent (77/517) of the vessels were scored as missing or nondiagnostic with 2D TOF, but were scored as diagnostic with PR-hyperTRICKS. Image quality was superior with PR-hyperTRICKS vs. 2D TOF (on a four-point scale, mean rank = 3.3 +/- 1.2 vs. 2.9 +/- 1.2, P < 0.0001). PR-hyperTRICKS produced images with high contrast-to-noise ratios (CNR) and high spatial and temporal resolution. 2D TOF images were of inferior quality due to moderate spatial resolution, inferior CNR, greater flow-related artifacts, and absence of temporal resolution. PR-hyperTRICKS provides superior preoperative assessment of lower limb ischemia compared to 2D TOF.

  4. Accurate x-ray spectroscopy

    International Nuclear Information System (INIS)

    Deslattes, R.D.

    1987-01-01

    Heavy ion accelerators are the most flexible and readily accessible sources of highly charged ions. These having only one or two remaining electrons have spectra whose accurate measurement is of considerable theoretical significance. Certain features of ion production by accelerators tend to limit the accuracy which can be realized in measurement of these spectra. This report aims to provide background about spectroscopic limitations and discuss how accelerator operations may be selected to permit attaining intrinsically limited data

  5. Time-resolved studies define the nature of toxic IAPP intermediates, providing insight for anti-amyloidosis therapeutics

    Science.gov (United States)

    Abedini, Andisheh; Plesner, Annette; Cao, Ping; Ridgway, Zachary; Zhang, Jinghua; Tu, Ling-Hsien; Middleton, Chris T; Chao, Brian; Sartori, Daniel J; Meng, Fanling; Wang, Hui; Wong, Amy G; Zanni, Martin T; Verchere, C Bruce; Raleigh, Daniel P; Schmidt, Ann Marie

    2016-01-01

    Islet amyloidosis by IAPP contributes to pancreatic β-cell death in diabetes, but the nature of toxic IAPP species remains elusive. Using concurrent time-resolved biophysical and biological measurements, we define the toxic species produced during IAPP amyloid formation and link their properties to induction of rat INS-1 β-cell and murine islet toxicity. These globally flexible, low order oligomers upregulate pro-inflammatory markers and induce reactive oxygen species. They do not bind 1-anilnonaphthalene-8-sulphonic acid and lack extensive β-sheet structure. Aromatic interactions modulate, but are not required for toxicity. Not all IAPP oligomers are toxic; toxicity depends on their partially structured conformational states. Some anti-amyloid agents paradoxically prolong cytotoxicity by prolonging the lifetime of the toxic species. The data highlight the distinguishing properties of toxic IAPP oligomers and the common features that they share with toxic species reported for other amyloidogenic polypeptides, providing information for rational drug design to treat IAPP induced β-cell death. DOI: http://dx.doi.org/10.7554/eLife.12977.001 PMID:27213520

  6. Data cache organization for accurate timing analysis

    DEFF Research Database (Denmark)

    Schoeberl, Martin; Huber, Benedikt; Puffitsch, Wolfgang

    2013-01-01

    it is important to classify memory accesses as either cache hit or cache miss. The addresses of instruction fetches are known statically and static cache hit/miss classification is possible for the instruction cache. The access to data that is cached in the data cache is harder to predict statically. Several...

  7. Communication latencies of Apple push notification messages relevant for delivery of time-critical information to anesthesia providers.

    Science.gov (United States)

    Rothman, Brian S; Dexter, Franklin; Epstein, Richard H

    2013-08-01

    Tablet computers and smart phones have gained popularity in anesthesia departments for educational and patient care purposes. VigiVU(™) is an iOS application developed at Vanderbilt University for remote viewing of perioperative information, including text message notifications delivered via the Apple Push Notification (APN) service. In this study, we assessed the reliability of the APN service. Custom software was written to send a message every minute to iOS devices (iPad(®), iPod Touch(®), and iPhone(®)) via wireless local area network (WLAN) and cellular pathways 24 hours a day over a 4-month period. Transmission and receipt times were recorded and batched by days, with latencies calculated as their differences. The mean, SEM, and the exact 95% upper confidence limits for the percent of days with ≥1 prolonged (>100 seconds) latency were calculated. Acceptable performance was defined as mean latency 100 seconds. Testing conditions included fixed locations of devices in high signal strength locations. Mean latencies were 173,000 iPad and iPod latencies, none were >100 seconds. For iPhone latencies, 0.03% ± 0.01% were >100 seconds. The 95% upper confidence limits of days with ≥1 prolonged latency were 42% (iPhone) and 5% to 8% (iPad, iPod). The APN service was reliable for all studied devices over WLAN and cellular pathways, and performance was better than third party paging systems using Internet connections previously investigated using the same criteria. However, since our study was a best-case assessment, testing is required at individual sites considering use of this technology for critical messaging. Furthermore, since the APN service may fail due to Internet or service provider disruptions, a backup paging system is recommended if the APN service were to be used for critical messaging.

  8. Accurate determination of 3-alkyl-2-methoxypyrazines in wines by gas chromatography quadrupole time-of-flight tandem mass spectrometry following solid-phase extraction and dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Fontana, Ariel; Rodríguez, Isaac; Cela, Rafael

    2017-09-15

    A new reliable method for the determination 3-alkyl-2-methoxypyrazines (MPs) in wine samples based on the sequential combination of solid-phase extraction (SPE), dispersive liquid-liquid microextraction (DLLME) and gas chromatography (GC) quadrupole time-of-flight accurate tandem mass spectrometry (QTOF-MS/MS) is presented. Primary extraction of target analytes was carried out by using a reversed-phase Oasis HLB (200mg) SPE cartridge combined with acetonitrile as elution solvent. Afterwards, the SPE extract was submitted to DLLME concentration using 0.06mL carbon tetrachloride (CCl 4 ) as extractant. Under final working conditions, sample concentration factors above 379 times and limits of quantification (LOQs) between 0.3 and 2.1ngL -1 were achieved. Moreover, the overall extraction efficiency of the method was unaffected by the particular characteristics of each wine; thus, accurate results (relative recoveries from 84 to 108% for samples spiked at concentrations from 5 to 25ngL -1 ) were obtained using matrix-matched standards, without using standard additions over every sample. Highly selective chromatographic records were achieved considering a mass window of 5mDa, centered in the quantification product ion corresponding to each compound. Twelve commercial wines, elaborated with grapes from different varieties and geographical origins, were processed with the optimized method. The 2-isobutyl-3-methoxypyrazine (IBMP) was determined at levels above the LOQs of the method in half of the samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Time allocation between feeding and incubation in uniparental arctic-breeding shorebirds: energy reserves provide leeway in a tight schedule

    NARCIS (Netherlands)

    Tulp, I.Y.M.; Schekkerman, H.

    2006-01-01

    Birds with uniparental incubation may face a time allocation problem between incubation and feeding. Eggs need regular warming to hatch successfully, but the parent must leave the nest to feed and safeguard its own survival. Time allocation during incubation is likely to depend on factors

  10. Exploring barriers to primary care for migrants in Greece in times of austerity: Perspectives of service providers.

    Science.gov (United States)

    Papadakaki, Maria; Lionis, Christos; Saridaki, Aristoula; Dowrick, Christopher; de Brún, Tomas; O'Reilly-de Brún, Mary; O'Donnell, Catherine A; Burns, Nicola; van Weel-Baumgarten, Evelyn; van den Muijsenbergh, Maria; Spiegel, Wolfgang; MacFarlane, Anne

    2017-12-01

    Migration in Europe is increasing at an unprecedented rate. There is an urgent need to develop 'migrant-sensitive healthcare systems'. However, there are many barriers to healthcare for migrants. Despite Greece's recent, significant experiences of inward migration during a period of economic austerity, little is known about Greek primary care service providers' experiences of delivering care to migrants. To identify service providers' views on the barriers to migrant healthcare. Qualitative study involving six participatory learning and action (PLA) focus group sessions with nine service providers. Data generation was informed by normalization process theory (NPT). Thematic analysis was applied to identify barriers to efficient migrant healthcare. Three main provider and system-related barriers emerged: (a) emphasis on major challenges in healthcare provision, (b) low perceived control and effectiveness to support migrant healthcare, and (c) attention to impoverished local population. The study identified major provider and system-related barriers in the provision of primary healthcare to migrants. It is important for the healthcare system in Greece to provide appropriate supports for communication in cross-cultural consultations for its diversifying population.

  11. Screening of 439 Pesticide Residues in Fruits and Vegetables by Gas Chromatography-Quadrupole-Time-of-Flight Mass Spectrometry Based on TOF Accurate Mass Database and Q-TOF Spectrum Library.

    Science.gov (United States)

    Li, Jian-Xun; Li, Xiao-Ying; Chang, Qiao-Ying; Li, Yan; Jin, Ling-He; Pang, Guo-Fang; Fan, Chun-Lin

    2018-05-03

    Because of its unique characteristics of accurate mass full-spectrum acquisition, high resolution, and fast acquisition rates, GC-quadrupole-time-of-flight MS (GC-Q-TOF/MS) has become a powerful tool for pesticide residue analysis. In this study, a TOF accurate mass database and Q-TOF spectrum library of 439 pesticides were established, and the parameters of the TOF database were optimized. Through solid-phase extraction (SPE), whereby pesticides are extracted from fruit and vegetable substrates by using 40 mL 1% acetic acid in acetonitrile (v/v), purified by the Carbon/NH₂ SPE cartridge, and finally detected by GC-Q-TOF/MS, the rapid analysis of 439 pesticides in fruits and vegetables can be achieved. The methodology verification results show that more than 70 and 91% of pesticides, spiked in fruits and vegetables with concentrations of 10 and 100 μg/kg, respectively, saw recoveries that conform to the European Commission's criterion of between 70 and 120% with RSD ≤20%. Eighty-one percent of pesticides have screening detection limits lower than 10 μg/kg, which makes this a reliable analysis technology for the monitoring of pesticide residues in fruits and vegetables. This technology was further validated for its characteristics of high precision, high speed, and high throughput through successful detection of 9817 samples during 2013-2015.

  12. Help at 3:00 AM! Providing 24/7 Timely Support to Online Students via a Virtual Assistant

    Science.gov (United States)

    Vu, Phu; Fredrickson, Scott; Meyer, Richard

    2016-01-01

    With a dearth of research on human-robot interaction in education and relatively high non-completion rates of online students, this study was conducted to determine the feasibility of using a virtual assistant (VA) to respond to questions and concerns of students and provide 24/7 online course content support. During a 16 week-long academic…

  13. Can linear trend analyses of NDVI time series data truly detect land degradation? Simulations may provide the answer

    CSIR Research Space (South Africa)

    Wessels, Konrad J

    2011-04-01

    Full Text Available of sufficient field data. The authors suggest that such an approach is not sufficiently rigorous. Therefore, they demonstrate an approach which simulates land degradation so that the intensity, rate and timing of the reduction in NDVI can be controlled, in order...

  14. Supporting Youth with Special Needs in Out-of-School Time: A Study of OST Providers in New Jersey

    Science.gov (United States)

    Sharp, Jane; Rodas, Elizabeth Rivera; Sadovnik, Alan R.

    2012-01-01

    Although the Americans with Disabilities Act (ADA) of 1990 requires accommodations for individuals with disabilities in community settings, many out-of-school time (OST) programs struggle to successfully support youth with special needs. Programs that fully include children with special needs are less available for school-age children and…

  15. Impact of a radio frequency management information system on the process and timing of providing respiratory care services.

    Science.gov (United States)

    Stoller, James K; Kester, Lucy; Orens, Douglas K; McCarthy, Kevin

    2002-08-01

    Although radio frequency (RF) systems have proliferated and are designed to simplify care delivery in many clinical settings, little information is available on the impact of such RF systems on the delivery of patient care. Having used a hand-held-device-based management information system in our Respiratory Therapy Section for 16 years, we assessed the impact of an RF system on the delivery of respiratory therapy (RT) services. A single nursing unit dedicated to pulmonary and ear, nose, and throat care was selected for the RF system trial. Baseline (pre-RF) data were collected over 2 separate 1-month intervals (February 1999 and February 2000). The main outcome measures were (1) the amount of time needed at the beginning of the shift to organize and assign orders for RT services, (2) the time interval between notification of an RT consult order and completion of the RT consult, and (3) the time interval between notification of an RT treatment order and completion of the RT treatment. The activities required for organizing and assigning the orders were manually timed. Starting 6 weeks after therapists were trained to use the RF system, similar data were collected while using the RF system for two 1-month intervals (February and March 2001). The mean +/- SD time interval between receiving an RT consult order and completing the consult was reduced from 7.8 +/- 18.9 h to 2.8 +/- 2.4 h (p = 0.002). The percentage of patients who waited longer than 8 hours between receipt of a consult order and completion of the consult decreased from 18% to 4.7% (p = 0.026). The total time required for organizing and assigning RT work was reduced from 81.6 min to 43.6 min. The RF system had several advantages over the hand-held-device-based system: (1) shorter interval between the order for and completion of an RT consult, (2) lower percentage of patients for whom the interval between the order and the consult exceeded 8 hours, and (3) less time required to make shift assignments

  16. HIV and cancer in Africa: mutual collaboration between HIV and cancer programs may provide timely research and public health data

    Directory of Open Access Journals (Sweden)

    Mbulaiteye Sam M

    2011-10-01

    Full Text Available Abstract The eruption of Kaposi sarcoma (KS and aggressive non-Hodgkin lymphoma (NHL in young homosexual men in 1981 in the West heralded the onset of the human immunodeficiency virus (HIV infection epidemic, which remains one of the biggest challenges to global public health and science ever. Because KS and NHL were increased >10,000 and 50-600 times, respectively, with HIV, they were designated AIDS defining cancers (ADC. Cervical cancer (CC, increased 5-10 times was also designated as an ADC. A few other cancers are elevated with HIV, including Hodgkin lymphoma (10 times, anal cancer (15-30 times, and lung cancer (4 times are designated as non-AIDS defining cancers (NADCs. Since 1996 when combination antiretroviral therapy (cART became widely available in the West, dramatic decreases in HIV mortality have been observed and substantial decrease in the incidence of ADCs. Coincidentally, the burden of NADCs has increased as people with HIV age with chronic HIV infection. The impact of HIV infection on cancer in sub-Saharan Africa, where two thirds of the epidemic is concentrated, remains poorly understood. The few studies conducted indicate that risks for ADCs are also increased, but quantitatively less so than in the West. The risks for many cancers with established viral associations, including liver and nasopharynx, which are found in Africa, do not appear to be increased. These data are limited because of competing mortality, and cancer is under diagnosed, pathological confirmation is rare, and cancer registration not widely practiced. The expansion of access to life-extending cART in sub-Saharan Africa, through programs such as the Global Fund for AIDS, Malaria, and Tuberculosis and the US President's Emergency Program for AIDS Relief (PEPFAR, is leading to dramatic lengthening of life of HIV patients, which will likely influence the spectrum and burden of cancer in patients with HIV. In this paper, we review current literature and explore

  17. Accurate control testing for clay liner permeability

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, R J

    1991-08-01

    Two series of centrifuge tests were carried out to evaluate the use of centrifuge modelling as a method of accurate control testing of clay liner permeability. The first series used a large 3 m radius geotechnical centrifuge and the second series a small 0.5 m radius machine built specifically for research on clay liners. Two permeability cells were fabricated in order to provide direct data comparisons between the two methods of permeability testing. In both cases, the centrifuge method proved to be effective and efficient, and was found to be free of both the technical difficulties and leakage risks normally associated with laboratory permeability testing of fine grained soils. Two materials were tested, a consolidated kaolin clay having an average permeability coefficient of 1.2{times}10{sup -9} m/s and a compacted illite clay having a permeability coefficient of 2.0{times}10{sup -11} m/s. Four additional tests were carried out to demonstrate that the 0.5 m radius centrifuge could be used for linear performance modelling to evaluate factors such as volumetric water content, compaction method and density, leachate compatibility and other construction effects on liner leakage. The main advantages of centrifuge testing of clay liners are rapid and accurate evaluation of hydraulic properties and realistic stress modelling for performance evaluations. 8 refs., 12 figs., 7 tabs.

  18. A System to Provide Real-Time Collaborative Situational Awareness by Web Enabling a Distributed Sensor Network

    Science.gov (United States)

    Panangadan, Anand; Monacos, Steve; Burleigh, Scott; Joswig, Joseph; James, Mark; Chow, Edward

    2012-01-01

    In this paper, we describe the architecture of both the PATS and SAP systems and how these two systems interoperate with each other forming a unified capability for deploying intelligence in hostile environments with the objective of providing actionable situational awareness of individuals. The SAP system works in concert with the UICDS information sharing middleware to provide data fusion from multiple sources. UICDS can then publish the sensor data using the OGC's Web Mapping Service, Web Feature Service, and Sensor Observation Service standards. The system described in the paper is able to integrate a spatially distributed sensor system, operating without the benefit of the Web infrastructure, with a remote monitoring and control system that is equipped to take advantage of SWE.

  19. Equipment upgrade - Accurate positioning of ion chambers

    International Nuclear Information System (INIS)

    Doane, Harry J.; Nelson, George W.

    1990-01-01

    Five adjustable clamps were made to firmly support and accurately position the ion Chambers, that provide signals to the power channels for the University of Arizona TRIGA reactor. The design requirements, fabrication procedure and installation are described

  20. Landsat ETM+ and SRTM Data Provide Near Real-Time Monitoring of Chimpanzee (Pan troglodytes Habitats in Africa

    Directory of Open Access Journals (Sweden)

    Samuel M. Jantz

    2016-05-01

    Full Text Available All four chimpanzee sub-species populations are declining due to multiple factors including human-caused habitat loss. Effective conservation efforts are therefore needed to ensure their long-term survival. Habitat suitability models serve as useful tools for conservation planning by depicting relative environmental suitability in geographic space over time. Previous studies mapping chimpanzee habitat suitability have been limited to small regions or coarse spatial and temporal resolutions. Here, we used Random Forests regression to downscale a coarse resolution habitat suitability calibration dataset to estimate habitat suitability over the entire chimpanzee range at 30-m resolution. Our model predicted habitat suitability well with an r2 of 0.82 (±0.002 based on 50-fold cross validation where 75% of the data was used for model calibration and 25% for model testing; however, there was considerable variation in the predictive capability among the four sub-species modeled individually. We tested the influence of several variables derived from Landsat Enhanced Thematic Mapper Plus (ETM+ that included metrics of forest canopy and structure for four three-year time periods between 2000 and 2012. Elevation, Landsat ETM+ band 5 and Landsat derived canopy cover were the strongest predictors; highly suitable areas were associated with dense tree canopy cover for all but the Nigeria-Cameroon and Central Chimpanzee sub-species. Because the models were sensitive to such temporally based predictors, our results are the first to highlight the value of integrating continuously updated variables derived from satellite remote sensing into temporally dynamic habitat suitability models to support  near real-time monitoring of habitat status and decision support systems.

  1. A race against time: can CO-OPs and provider start-ups survive in the health insurance marketplaces?

    Science.gov (United States)

    Eggbeer, Bill

    2015-12-01

    > The Affordable Care Act's state and federal health insurance marketplaces, designed to provide affordable insurance coverage to individuals and small groups, are proving hostile territory to new market entrants. Efforts to inject competition into the marketplaces are being challenged by the wide-scale withdrawal o consumer-operated and oriented plans (CO-OPs). Meanwhile, premiums appear likely to increase for consumers as plans seek to balance medical losses. Flaws in the "Three R's" (reinsurance, risk corridors, and risk-adjustment) program are viewed as a threat to the survival of CO-OPs and start-ups.

  2. Radiation-Resistant Photon-Counting Detector Package Providing Sub-ps Stability for Laser Time Transfer in Space

    Science.gov (United States)

    Prochzaka, Ivan; Kodat, Jan; Blazej, Josef; Sun, Xiaoli (Editor)

    2015-01-01

    We are reporting on a design, construction and performance of photon-counting detector packages based on silicon avalanche photodiodes. These photon-counting devices have been optimized for extremely high stability of their detection delay. The detectors have been designed for future applications in fundamental metrology and optical time transfer in space. The detectors have been qualified for operation in space missions. The exceptional radiation tolerance of the detection chip itself and of all critical components of a detector package has been verified in a series of experiments.

  3. Resources and Capabilities of the Department of Veterans Affairs to Provide Timely and Accessible Care to Veterans

    Science.gov (United States)

    Hussey, Peter S.; Ringel, Jeanne S.; Ahluwalia, Sangeeta; Price, Rebecca Anhang; Buttorff, Christine; Concannon, Thomas W.; Lovejoy, Susan L.; Martsolf, Grant R.; Rudin, Robert S.; Schultz, Dana; Sloss, Elizabeth M.; Watkins, Katherine E.; Waxman, Daniel; Bauman, Melissa; Briscombe, Brian; Broyles, James R.; Burns, Rachel M.; Chen, Emily K.; DeSantis, Amy Soo Jin; Ecola, Liisa; Fischer, Shira H.; Friedberg, Mark W.; Gidengil, Courtney A.; Ginsburg, Paul B.; Gulden, Timothy; Gutierrez, Carlos Ignacio; Hirshman, Samuel; Huang, Christina Y.; Kandrack, Ryan; Kress, Amii; Leuschner, Kristin J.; MacCarthy, Sarah; Maksabedian, Ervant J.; Mann, Sean; Matthews, Luke Joseph; May, Linnea Warren; Mishra, Nishtha; Miyashiro, Lisa; Muchow, Ashley N.; Nelson, Jason; Naranjo, Diana; O'Hanlon, Claire E.; Pillemer, Francesca; Predmore, Zachary; Ross, Rachel; Ruder, Teague; Rutter, Carolyn M.; Uscher-Pines, Lori; Vaiana, Mary E.; Vesely, Joseph V.; Hosek, Susan D.; Farmer, Carrie M.

    2016-01-01

    Abstract The Veterans Access, Choice, and Accountability Act of 2014 addressed the need for access to timely, high-quality health care for veterans. Section 201 of the legislation called for an independent assessment of various aspects of veterans' health care. The RAND Corporation was tasked with an assessment of the Department of Veterans Affairs (VA) current and projected health care capabilities and resources. An examination of data from a variety of sources, along with a survey of VA medical facility leaders, revealed the breadth and depth of VA resources and capabilities: fiscal resources, workforce and human resources, physical infrastructure, interorganizational relationships, and information resources. The assessment identified barriers to the effective use of these resources and capabilities. Analysis of data on access to VA care and the quality of that care showed that almost all veterans live within 40 miles of a VA health facility, but fewer have access to VA specialty care. Veterans usually receive care within 14 days of their desired appointment date, but wait times vary considerably across VA facilities. VA has long played a national leadership role in measuring the quality of health care. The assessment showed that VA health care quality was as good or better on most measures compared with other health systems, but quality performance lagged at some VA facilities. VA will require more resources and capabilities to meet a projected increase in veterans' demand for VA care over the next five years. Options for increasing capacity include accelerated hiring, full nurse practice authority, and expanded use of telehealth. PMID:28083424

  4. The Healthcare Improvement Scotland evidence note rapid review process: providing timely, reliable evidence to inform imperative decisions on healthcare.

    Science.gov (United States)

    McIntosh, Heather M; Calvert, Julie; Macpherson, Karen J; Thompson, Lorna

    2016-06-01

    Rapid review has become widely adopted by health technology assessment agencies in response to demand for evidence-based information to support imperative decisions. Concern about the credibility of rapid reviews and the reliability of their findings has prompted a call for wider publication of their methods. In publishing this overview of the accredited rapid review process developed by Healthcare Improvement Scotland, we aim to raise awareness of our methods and advance the discourse on best practice. Healthcare Improvement Scotland produces rapid reviews called evidence notes using a process that has achieved external accreditation through the National Institute for Health and Care Excellence. Key components include a structured approach to topic selection, initial scoping, considered stakeholder involvement, streamlined systematic review, internal quality assurance, external peer review and updating. The process was introduced in 2010 and continues to be refined over time in response to user feedback and operational experience. Decision-makers value the responsiveness of the process and perceive it as being a credible source of unbiased evidence-based information supporting advice for NHSScotland. Many agencies undertaking rapid reviews are striving to balance efficiency with methodological rigour. We agree that there is a need for methodological guidance and that it should be informed by better understanding of current approaches and the consequences of different approaches to streamlining systematic review methods. Greater transparency in the reporting of rapid review methods is essential to enable that to happen.

  5. Negative chemical ionization gas chromatography coupled to hybrid quadrupole time-of-flight mass spectrometry and automated accurate mass data processing for determination of pesticides in fruit and vegetables.

    Science.gov (United States)

    Besil, Natalia; Uclés, Samanta; Mezcúa, Milagros; Heinzen, Horacio; Fernández-Alba, Amadeo R

    2015-08-01

    Gas chromatography coupled to high resolution hybrid quadrupole time-of-flight mass spectrometry (GC-QTOF MS), operating in negative chemical ionization (NCI) mode and combining full scan with MSMS experiments using accurate mass analysis, has been explored for the automated determination of pesticide residues in fruit and vegetables. Seventy compounds were included in this approach where 50 % of them are not approved by the EU legislation. A global 76 % of the analytes could be identified at 1 μg kg(-1). Recovery studies were developed at three concentration levels (1, 5, and 10 μg kg(-1)). Seventy-seven percent of the detected pesticides at the lowest level yielded recoveries within the 70 %-120 % range, whereas 94 % could be quantified at 5 μg kg(-1), and the 100 % were determined at 10 μg kg(-1). Good repeatability, expressed as relative standard deviation (RSD home-made database was developed and applied to an automatic accurate mass data processing. Measured mass accuracies of the generated ions were mainly less than 5 ppm for at least one diagnostic ion. When only one ion was obtained in the single-stage NCI-MS, a representative product ion from MSMS experiments was used as identification criterion. A total of 30 real samples were analyzed and 67 % of the samples were positive for 12 different pesticides in the range 1.0-1321.3 μg kg(-1).

  6. Time Delay Mechanical-noise Cancellation (TDMC) to Provide Order of Magnitude Improvements in Radio Science Observations

    Science.gov (United States)

    Atkinson, D. H.; Babuscia, A.; Lazio, J.; Asmar, S.

    2017-12-01

    Many Radio Science investigations, including the determinations of planetary masses, measurements of planetary atmospheres, studies of the solar wind, and solar system tests of relativistic gravity, rely heavily on precision Doppler tracking. Recent and currently proposed missions such as VERITAS, Bepi Colombo, Juno have shown that the largest error source in the precision Doppler tracking data is noise in the Doppler system. This noise is attributed to un-modeled motions of the ground antenna's phase center and is commonly referred to as "antenna mechanical noise." Attempting to reduce this mechanical noise has proven difficult since the deep space communications antennas utilize large steel structures that are already optimized for mechanical stability. Armstrong et al. (2008) have demonstrated the Time Delay Mechanical-noise Cancellation (TDMC) concept using Goldstone DSN antennas (70 m & 34 m) and the Cassinispacecraft to show that the mechanical noise of the 70 m antenna could be suppressed when two-way Doppler tracking from the 70 m antenna and the receive-only Doppler data from the smaller, stiffer 34 m antenna were combined with suitable delays. The proof-of-concept confirmed that the mechanical noise in the final Doppler observable was reduced to that of the stiffer, more stable antenna. Caltech's Owens Valley Radio Observatory (OVRO) near Bishop, CA now has six 10.4 m diameter antennas, a consequence of the closure of Combined Array for Research in Millimeter Astronomy (CARMA). In principle, a 10 m antenna can lead to an order-of-magnitude improvement for the mechanical noise correction, as the smaller dish offers better mechanical stability compared to a DSN 34-m antenna. These antennas also have existing Ka-band receiving systems, and preliminary discussions with the OVRO staff suggest that much of the existing signal path could be used for Radio Science observations.

  7. A clip-based protocol for breast boost radiotherapy provides clear target visualisation and demonstrates significant volume reduction over time

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Lorraine [Department of Radiation Oncology, Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales (Australia); Cox, Jennifer [Department of Radiation Oncology, Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales (Australia); Faculty of Health Sciences, University of Sydney, Sydney, New South Wales (Australia); Morgia, Marita [Department of Radiation Oncology, Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales (Australia); Atyeo, John [Faculty of Health Sciences, University of Sydney, Sydney, New South Wales (Australia); Lamoury, Gillian [Department of Radiation Oncology, Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales (Australia)

    2015-09-15

    The clinical target volume (CTV) for early stage breast cancer is difficult to clearly identify on planning computed tomography (CT) scans. Surgical clips inserted around the tumour bed should help to identify the CTV, particularly if the seroma has been reabsorbed, and enable tracking of CTV changes over time. A surgical clip-based CTV delineation protocol was introduced. CTV visibility and its post-operative shrinkage pattern were assessed. The subjects were 27 early stage breast cancer patients receiving post-operative radiotherapy alone and 15 receiving post-operative chemotherapy followed by radiotherapy. The radiotherapy alone (RT/alone) group received a CT scan at median 25 days post-operatively (CT1rt) and another at 40 Gy, median 68 days (CT2rt). The chemotherapy/RT group (chemo/RT) received a CT scan at median 18 days post-operatively (CT1ch), a planning CT scan at median 126 days (CT2ch), and another at 40 Gy (CT3ch). There was no significant difference (P = 0.08) between the initial mean CTV for each cohort. The RT/alone cohort showed significant CTV volume reduction of 38.4% (P = 0.01) at 40 Gy. The Chemo/RT cohort had significantly reduced volumes between CT1ch: median 54 cm{sup 3} (4–118) and CT2ch: median 16 cm{sup 3}, (2–99), (P = 0.01), but no significant volume reduction thereafter. Surgical clips enable localisation of the post-surgical seroma for radiotherapy targeting. Most seroma shrinkage occurs early, enabling CT treatment planning to take place at 7 weeks, which is within the 9 weeks recommended to limit disease recurrence.

  8. A clip-based protocol for breast boost radiotherapy provides clear target visualisation and demonstrates significant volume reduction over time

    International Nuclear Information System (INIS)

    Lewis, Lorraine; Cox, Jennifer; Morgia, Marita; Atyeo, John; Lamoury, Gillian

    2015-01-01

    The clinical target volume (CTV) for early stage breast cancer is difficult to clearly identify on planning computed tomography (CT) scans. Surgical clips inserted around the tumour bed should help to identify the CTV, particularly if the seroma has been reabsorbed, and enable tracking of CTV changes over time. A surgical clip-based CTV delineation protocol was introduced. CTV visibility and its post-operative shrinkage pattern were assessed. The subjects were 27 early stage breast cancer patients receiving post-operative radiotherapy alone and 15 receiving post-operative chemotherapy followed by radiotherapy. The radiotherapy alone (RT/alone) group received a CT scan at median 25 days post-operatively (CT1rt) and another at 40 Gy, median 68 days (CT2rt). The chemotherapy/RT group (chemo/RT) received a CT scan at median 18 days post-operatively (CT1ch), a planning CT scan at median 126 days (CT2ch), and another at 40 Gy (CT3ch). There was no significant difference (P = 0.08) between the initial mean CTV for each cohort. The RT/alone cohort showed significant CTV volume reduction of 38.4% (P = 0.01) at 40 Gy. The Chemo/RT cohort had significantly reduced volumes between CT1ch: median 54 cm 3 (4–118) and CT2ch: median 16 cm 3 , (2–99), (P = 0.01), but no significant volume reduction thereafter. Surgical clips enable localisation of the post-surgical seroma for radiotherapy targeting. Most seroma shrinkage occurs early, enabling CT treatment planning to take place at 7 weeks, which is within the 9 weeks recommended to limit disease recurrence

  9. A stabilized second-order time accurate finite element formulation for incompressible viscous flow with heat transfer; Uma formulacao de elementos finitos estabilizada de segunda ordem no tempo para escoamentos viscosos com transferencia de calor

    Energy Technology Data Exchange (ETDEWEB)

    Curi, Marcos Filardy

    2011-07-01

    In view of the problem of global warming and the search for clean energy sources, a worldwide expansion on the use of nuclear energy is foreseen. Thus, the development of science and technology regarding nuclear power plants is essential, in particular in the field of reactor engineering. Fluid mechanics and heat transfer play an important role in the development of nuclear reactors. Computational Fluid Mechanics (CFD) is becoming ever more important in the optimization of cost and safety of the designs. This work presents a stabilized second-order time accurate finite element formulation for incompressible flows with heat transfer. A second order time discretization precedes a spatial discretization using finite elements. The terms that stabilize the finite element method arise naturally from the discretization process, rather than being introduced a priori in the variational formulation. The method was implemented in the program 'ns{sub n}ew{sub s}olvec2d{sub av}2{sub M}PI' written in FORTRAN90, developed in the Parallel Computing Laboratory at the Institute of Nuclear Engineering (LCP/IEN). Numerical solutions of some representative examples, including free, mixed and forced convection, demonstrate that the proposed stabilized formulation attains very good agreement with experimental and computational results available in the literature. (author)

  10. Novel Accurate Bacterial Discrimination by MALDI-Time-of-Flight MS Based on Ribosomal Proteins Coding in S10-spc-alpha Operon at Strain Level S10-GERMS

    Science.gov (United States)

    Tamura, Hiroto; Hotta, Yudai; Sato, Hiroaki

    2013-08-01

    Matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is one of the most widely used mass-based approaches for bacterial identification and classification because of the simple sample preparation and extremely rapid analysis within a few minutes. To establish the accurate MALDI-TOF MS bacterial discrimination method at strain level, the ribosomal subunit proteins coded in the S 10-spc-alpha operon, which encodes half of the ribosomal subunit protein and is highly conserved in eubacterial genomes, were selected as reliable biomarkers. This method, named the S10-GERMS method, revealed that the strains of genus Pseudomonas were successfully identified and discriminated at species and strain levels, respectively; therefore, the S10-GERMS method was further applied to discriminate the pathovar of P. syringae. The eight selected biomarkers (L24, L30, S10, S12, S14, S16, S17, and S19) suggested the rapid discrimination of P. syringae at the strain (pathovar) level. The S10-GERMS method appears to be a powerful tool for rapid and reliable bacterial discrimination and successful phylogenetic characterization. In this article, an overview of the utilization of results from the S10-GERMS method is presented, highlighting the characterization of the Lactobacillus casei group and discrimination of the bacteria of genera Bacillus and Sphingopyxis despite only two and one base difference in the 16S rRNA gene sequence, respectively.

  11. Accurate thickness measurement of graphene

    International Nuclear Information System (INIS)

    Shearer, Cameron J; Slattery, Ashley D; Stapleton, Andrew J; Shapter, Joseph G; Gibson, Christopher T

    2016-01-01

    Graphene has emerged as a material with a vast variety of applications. The electronic, optical and mechanical properties of graphene are strongly influenced by the number of layers present in a sample. As a result, the dimensional characterization of graphene films is crucial, especially with the continued development of new synthesis methods and applications. A number of techniques exist to determine the thickness of graphene films including optical contrast, Raman scattering and scanning probe microscopy techniques. Atomic force microscopy (AFM), in particular, is used extensively since it provides three-dimensional images that enable the measurement of the lateral dimensions of graphene films as well as the thickness, and by extension the number of layers present. However, in the literature AFM has proven to be inaccurate with a wide range of measured values for single layer graphene thickness reported (between 0.4 and 1.7 nm). This discrepancy has been attributed to tip-surface interactions, image feedback settings and surface chemistry. In this work, we use standard and carbon nanotube modified AFM probes and a relatively new AFM imaging mode known as PeakForce tapping mode to establish a protocol that will allow users to accurately determine the thickness of graphene films. In particular, the error in measuring the first layer is reduced from 0.1–1.3 nm to 0.1–0.3 nm. Furthermore, in the process we establish that the graphene-substrate adsorbate layer and imaging force, in particular the pressure the tip exerts on the surface, are crucial components in the accurate measurement of graphene using AFM. These findings can be applied to other 2D materials. (paper)

  12. Field and laboratory studies provide insights into the meaning of day-time activity in a subterranean rodent (Ctenomys aff. knighti, the tuco-tuco.

    Directory of Open Access Journals (Sweden)

    Barbara M Tomotani

    Full Text Available South American subterranean rodents (Ctenomys aff. knighti, commonly known as tuco-tucos, display nocturnal, wheel-running behavior under light-dark (LD conditions, and free-running periods >24 h in constant darkness (DD. However, several reports in the field suggested that a substantial amount of activity occurs during daylight hours, leading us to question whether circadian entrainment in the laboratory accurately reflects behavior in natural conditions. We compared circadian patterns of locomotor activity in DD of animals previously entrained to full laboratory LD cycles (LD12:12 with those of animals that were trapped directly from the field. In both cases, activity onsets in DD immediately reflected the previous dark onset or sundown. Furthermore, freerunning periods upon release into DD were close to 24 h indicating aftereffects of prior entrainment, similarly in both conditions. No difference was detected in the phase of activity measured with and without access to a running wheel. However, when individuals were observed continuously during daylight hours in a semi-natural enclosure, they emerged above-ground on a daily basis. These day-time activities consisted of foraging and burrow maintenance, suggesting that the designation of this species as nocturnal might be inaccurate in the field. Our study of a solitary subterranean species suggests that the circadian clock is entrained similarly under field and laboratory conditions and that day-time activity expressed only in the field is required for foraging and may not be time-dictated by the circadian pacemaker.

  13. Library Users Expect Link Resolvers to Provide Full Text While Librarians Expect Accurate Results. A review of: Wakimoto, Jina Choi, David S. Walker, and Katherine S. Dabbour. “The Myths and Realities of SFX in Academic Libraries.” The Journal of Academic Librarianship 32.2 (Mar. 2006: 127‐ 36.

    Directory of Open Access Journals (Sweden)

    Wendy Furlan

    2006-12-01

    Full Text Available Objective – To determine how successfulthe link resolver, SFX, is in meeting the expectations of library users and librarians.Design – Analysis of an online user survey, library staff focus groups, retrospective analysis of system statistics, and test searches.Setting – Two California State University campus libraries in the United States: Northbridge, with over 31,000 students on campus, and San Marcos, with over 7,300 students on campus.Subjects – A total of 453 online survey responses were submitted from library users, 421 from Northbridge and 32 from SanMarcos. Twenty librarians took part in the focus groups conducted with library staff consisting of 14 of the 23 librarians from Northbridge (2 from technical services and 12 from public services, and 6 of the 10 San Marcos librarians (3 from technical services and 3 from public services. No further information was provided on the characteristics of the subjects.Methods – An online survey was offered to users of the two campus libraries for a two week period in May 2004. The survey consisted of 8 questions, 7 fixed response and 1 free text. Survey distribution was enabled via a different mechanism at each campus. The Northbridge library offered the survey to users via a pop‐up window each time the SFX service was clicked on, while the San Marcos library presented the survey as a link from the library’s home page. Survey responses from both campuses were combined and analysed together. Focus groups were conducted with librarians from each campus library on April 20th, 21st, and 29th, 2004. Librarians attended focus groups only with others from their own campus. Statistics were gathered from each campus’ local SFX system for the 3‐month period from September 14, 2004, to December 14,2004. Statistics from each campus were combined for analysis. The authors also conducted 224 test searches over the 3‐month period from July to September, 2004.Main results – Analysis of the

  14. Automatic updating of times remaining in surgical cases using bayesian analysis of historical case duration data and "instant messaging" updates from anesthesia providers.

    Science.gov (United States)

    Dexter, Franklin; Epstein, Richard H; Lee, John D; Ledolter, Johannes

    2009-03-01

    Operating room (OR) whiteboards (status displays) communicate times remaining for ongoing cases to perioperative stakeholders (e.g., postanesthesia care unit, anesthesiologists, holding area, and control desks). Usually, scheduled end times are shown for each OR. However, these displays are inaccurate for predicting the time that remains in a case. Once a case scheduled for 2 h has been on-going for 1.5 h, the median time remaining is not 0.5 h but longer, and the amount longer differs among procedures. We derived the conditional Bayesian lower prediction bound of a case's duration, conditional on the minutes of elapsed OR time. Our derivations make use of the posterior predictive distribution of OR times following an exponential of a scaled Student t distribution that depends on the scheduled OR time and several parameters calculated from historical case duration data. The statistical method was implemented using Structured Query Language (SQL) running on the anesthesia information management system (AIMS) database server. In addition, AIMS workstations were sent instant messages displaying a pop-up dialog box asking for anesthesia providers' estimates for remaining times. The dialogs caused negotiated interruptions (i.e., the anesthesia provider could reply immediately, keep the dialog displayed, or defer response). There were no announcements, education, or efforts to promote buy-in. After a case had been in the OR longer than scheduled, the median remaining OR time for the case changes little over time (e.g., 35 min left at 2:30 pm and also at 3:00 pm while the case was still on-going). However, the remaining time differs substantially among surgeons and scheduled procedure(s) (16 min longer [10th percentile], 35 min [50th], and 86 min [90th]). We therefore implemented an automatic method to estimate the times remaining in cases. The system was operational for >119 of each day's 120 5-min intervals. When instant message dialogs appearing on AIMS workstations

  15. Can providing a morning healthy snack help to reduce hunger during school time? Experimental evidence from an elementary school in Connecticut.

    Science.gov (United States)

    Castellari, Elena; Berning, Joshua P

    2016-11-01

    While children may be naturally inclined to regulate their hunger, they are also guided by adults and influenced by environmental constraints regarding when and how much to eat. As such, the timing and availability of meals could alter a child's natural eating habits. This could impact the nutritional quality of what they eat as well. We conducted a field experiment with three fourth grade classes at a public elementary school in Eastern Connecticut to analyze if providing a nutritious snack one hour prior to lunch effects a child's level of hunger and consequently their lunch-time consumption. We found students shift their caloric and nutrient intake from lunch to snack time. In addition, we found a significant reduction in student hunger. Our results highlight the importance in considering the timing and quality of meals provided during school time. In our sample, current snack and lunch schedule may not be optimal and changing it can have an impact on the wellbeing of students. Providing healthful options for snack could be an effective way to improve student diets while preserving their ability to make their own choices. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Ichthyoplankton Time Series: A Potential Ocean Observing Network to Provide Indicators of Climate Impacts on Fish Communities along the West Coast of North America

    Science.gov (United States)

    Koslow, J. A.; Brodeur, R.; Duffy-Anderson, J. T.; Perry, I.; jimenez Rosenberg, S.; Aceves, G.

    2016-02-01

    Ichthyoplankton time series available from the Bering Sea, Gulf of Alaska and California Current (Oregon to Baja California) provide a potential ocean observing network to assess climate impacts on fish communities along the west coast of North America. Larval fish abundance reflects spawning stock biomass, so these data sets provide indicators of the status of a broad range of exploited and unexploited fish populations. Analyses to date have focused on individual time series, which generally exhibit significant change in relation to climate. Off California, a suite of 24 midwater fish taxa have declined > 60%, correlated with declining midwater oxygen concentrations, and overall larval fish abundance has declined 72% since 1969, a trend based on the decline of predominantly cool-water affinity taxa in response to warming ocean temperatures. Off Oregon, there were dramatic differences in community structure and abundance of larval fishes between warm and cool ocean conditions. Midwater deoxygenation and warming sea surface temperature trends are predicted to continue as a result of global climate change. US, Canadian, and Mexican fishery scientists are now collaborating in a virtual ocean observing network to synthesize available ichthyoplankton time series and compare patterns of change in relation to climate. This will provide regional indicators of populations and groups of taxa sensitive to warming, deoxygenation and potentially other stressors, establish the relevant scales of coherence among sub-regions and across Large Marine Ecosystems, and provide the basis for predicting future climate change impacts on these ecosystems.

  17. Developing a Tool to Assess the Capacity of Out-of-School Time Program Providers to Implement Policy, Systems, and Environmental Change.

    Science.gov (United States)

    Leeman, Jennifer; Blitstein, Jonathan L; Goetz, Joshua; Moore, Alexis; Tessman, Nell; Wiecha, Jean L

    2016-08-11

    Little is known about public health practitioners' capacity to change policies, systems, or environments (PSEs), in part due to the absence of measures. To address this need, we partnered with the Alliance for a Healthier Generation (Alliance) to develop and test a theory-derived measure of the capacity of out-of-school time program providers to improve students' level of nutrition and physical activity through changes in PSEs. The measure was developed and tested through an engaged partnership with staff working on the Alliance's Healthy Out-of-School Time (HOST) Initiative. In total, approximately 2,000 sites nationwide are engaged in the HOST Initiative, which serves predominantly high-need children and youths. We partnered with the Alliance to conduct formative work that would help develop a survey that assessed attitudes/beliefs, social norms, external resources/supports, and self-efficacy. The survey was administered to providers of out-of-school time programs who were implementing the Alliance's HOST Initiative. Survey respondents were 185 out-of-school time program providers (53% response rate). Exploratory factor analysis yielded a 4-factor model that explained 44.7% of the variance. Factors pertained to perceptions of social norms (6 items) and self-efficacy to build support and engage a team (4 items) and create (5 items) and implement (3 items) an action plan. We report initial development and factor analysis of a tool that the Alliance can use to assess the capacity of after-school time program providers, which is critical to targeting capacity-building interventions and assessing their effectiveness. Study findings also will inform the development of measures to assess individual capacity to plan and implement other PSE interventions.

  18. Integrated real-time information to use in commercial, logistics and operational activities provide by the national control center operation of Transpetro

    Energy Technology Data Exchange (ETDEWEB)

    Aniceto, Hello A. R. [National Control Center Operation Transpetro, Rio de Janeiro, (Brazil)

    2010-07-01

    TRANSPETRO needed real time computational tools to manage its commercial, logistics and operational activities more efficiently. TRANSPETRO's National Control Center Operation developed an information site that provides information in real time on the process plans involved in each operation, using a Plant Information Management System (PIMS). SCADA systems were introduced during 2009 and 2010. This paper reports on the global introduction of the site and its basic architecture. Every screen displays the overall data in real time on movement in volume in pipeline operated by TRANSPETRO. The products transported are tracked for each infrastructure and are shown on dynamic geographic maps. Applications have been developed to improve the quality of information available to customers. It was found that the development of this site using PIMS technology brought gains in support to decision-making at the strategic and tactical levels for TRANSPETRO.

  19. SU-D-BRF-05: A Novel System to Provide Real-Time Image-Guidance for Intrauterine Tandem Insertion and Placement

    Energy Technology Data Exchange (ETDEWEB)

    Price, M; Fontenot, J [pF Biomedical Solutions LLC, Baton Rouge, LA (United States)

    2014-06-01

    Purpose: To develop a system that provides real-time image-guidance for intrauterine tandem insertion and placement for brachytherapy. Methods: The conceptualized system consists of an intrauterine tandem with a transparent, lensed tip, a flexible miniature fiber optic scope, light source and interface for CCD coupling. The tandem tip was designed to act as a lens providing a wide field-of-view (FOV) with minimal image distortion and focus length appropriate for the application. The system is designed so that once inserted, the image-guidance component of the system can be removed and brachytherapy can be administered without interfering with source transport or disturbing tandem placement. Proof-of-principle studies were conducted to assess the conceptualized system's (1) lens functionality (clarity, focus and FOV) (2) and ability to visualize the cervical os of a female placed in the lithotomy position. Results: A prototype of this device was constructed using a commercial tandem modified to incorporate a transparent tip that internally coupled with a 1.9mm diameter fiber optic cable. The 900mm-long cable terminated at an interface that provided illumination as well as facilitated visualization of patient anatomy on a computer. The system provided a 23mm FOV with a focal length of 1cm and provided clear visualization of the cervix, cervical fornix and cervical os. The optical components of the system are easily removed without perturbing the position of a tandem placed in a common fixation clamp. Conclusion: Clinicians frequently encounter difficulty inserting an intrauterine tandem through the cervical os, circumventing fibrotic tissue or masses within the uterus, and positioning the tandem without perforating the uterus. To mitigate these challenges, we have designed and conducted proof-of- principle studies to discern the utility of a prototype device that provides real-time image-guidance for intrauterine tandem placement using fiber optic components.

  20. A Highly Accurate Approach for Aeroelastic System with Hysteresis Nonlinearity

    Directory of Open Access Journals (Sweden)

    C. C. Cui

    2017-01-01

    Full Text Available We propose an accurate approach, based on the precise integration method, to solve the aeroelastic system of an airfoil with a pitch hysteresis. A major procedure for achieving high precision is to design a predictor-corrector algorithm. This algorithm enables accurate determination of switching points resulting from the hysteresis. Numerical examples show that the results obtained by the presented method are in excellent agreement with exact solutions. In addition, the high accuracy can be maintained as the time step increases in a reasonable range. It is also found that the Runge-Kutta method may sometimes provide quite different and even fallacious results, though the step length is much less than that adopted in the presented method. With such high computational accuracy, the presented method could be applicable in dynamical systems with hysteresis nonlinearities.

  1. Medicare Provider Data - Hospice Providers

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Hospice Utilization and Payment Public Use File provides information on services provided to Medicare beneficiaries by hospice providers. The Hospice PUF...

  2. Highly Accurate Prediction of Jobs Runtime Classes

    OpenAIRE

    Reiner-Benaim, Anat; Grabarnick, Anna; Shmueli, Edi

    2016-01-01

    Separating the short jobs from the long is a known technique to improve scheduling performance. In this paper we describe a method we developed for accurately predicting the runtimes classes of the jobs to enable this separation. Our method uses the fact that the runtimes can be represented as a mixture of overlapping Gaussian distributions, in order to train a CART classifier to provide the prediction. The threshold that separates the short jobs from the long jobs is determined during the ev...

  3. When Is Network Lasso Accurate?

    Directory of Open Access Journals (Sweden)

    Alexander Jung

    2018-01-01

    Full Text Available The “least absolute shrinkage and selection operator” (Lasso method has been adapted recently for network-structured datasets. In particular, this network Lasso method allows to learn graph signals from a small number of noisy signal samples by using the total variation of a graph signal for regularization. While efficient and scalable implementations of the network Lasso are available, only little is known about the conditions on the underlying network structure which ensure network Lasso to be accurate. By leveraging concepts of compressed sensing, we address this gap and derive precise conditions on the underlying network topology and sampling set which guarantee the network Lasso for a particular loss function to deliver an accurate estimate of the entire underlying graph signal. We also quantify the error incurred by network Lasso in terms of two constants which reflect the connectivity of the sampled nodes.

  4. The Accurate Particle Tracer Code

    OpenAIRE

    Wang, Yulei; Liu, Jian; Qin, Hong; Yu, Zhi

    2016-01-01

    The Accurate Particle Tracer (APT) code is designed for large-scale particle simulations on dynamical systems. Based on a large variety of advanced geometric algorithms, APT possesses long-term numerical accuracy and stability, which are critical for solving multi-scale and non-linear problems. Under the well-designed integrated and modularized framework, APT serves as a universal platform for researchers from different fields, such as plasma physics, accelerator physics, space science, fusio...

  5. The Rice Enhancer of Zeste [E(z] Genes SDG711 and SDG718 are respectively involved in Long Day and Short Day Signaling to Mediate the Accurate Photoperiod Control of Flowering time

    Directory of Open Access Journals (Sweden)

    Xiaoyun eLiu

    2014-10-01

    Full Text Available Recent advances in rice flowering studies have shown that the accurate control of flowering by photoperiod is regulated by key mechanisms that involve the regulation of flowering genes including Hd1, Ehd1, Hd3a, and RFT1. The chromatin mechanism involved in the regulation of rice flowering genes is presently not well known. Here we show that the rice E(z genes SDG711 and SDG718, which encode the Polycomb Repressive Complex2 (PRC2 key subunit that is required for trimethylation of histone H3 lysine 27 (H3K27me3, are respectively involved in long day (LD and short day (SD regulation of key flowering genes. The expression of SDG711 and SDG718 is induced by LD and SD, respectively. Over-expression and down-regulation of SDG711 respectively repressed and promoted flowering in LD, but had no effect in SD. By contrast, down-regulation of SDG718 had no effect in LD but delayed flowering in SD. SDG711 and SDG718 repressed OsLF (a repressor of Hd1 respectively in LD and SD, leading to a higher expression of Hd1 thus late flowering in LD and early flowering in SD. SDG711 was also found to be involved in the repression of Ehd1 in LD. SDG711 was shown to directly target to OsLF and Ehd1 loci to mediate H3K27me3 and gene repression. The function of the rice E(z genes in LD repression and SD promotion of flowering suggests that PRC2-mediated epigenetic repression of gene expression is involved in the accurate photoperiod control of rice flowering.

  6. Connecting the snowpack to the internet of things: an IPv6 architecture for providing real-time measurements of hydrologic systems

    Science.gov (United States)

    Kerkez, B.; Zhang, Z.; Oroza, C.; Glaser, S. D.; Bales, R. C.

    2012-12-01

    We describe our improved, robust, and scalable architecture by which to rapidly instrument large-scale watersheds, while providing the resulting data in real-time. Our system consists of more than twenty wireless sensor networks and thousands of sensors, which will be deployed in the American River basin (5000 sq. km) of California. The core component of our system is known as a mote, a tiny, ultra-low-power, embedded wireless computer that can be used for any number of sensing applications. Our new generation of motes is equipped with IPv6 functionality, effectively giving each sensor in the field its own unique IP address, thus permitting users to remotely interact with the devices without going through intermediary services. Thirty to fifty motes will be deployed across 1-2 square kilometer regions to form a mesh-based wireless sensor network. Redundancy of local wireless links will ensure that data will always be able to traverse the network, even if hash wintertime conditions adversely affect some network nodes. These networks will be used to develop spatial estimates of a number of hydrologic parameters, focusing especially on snowpack. Each wireless sensor network has one main network controller, which is responsible with interacting with an embedded Linux computer to relay information across higher-powered, long-range wireless links (cell modems, satellite, WiFi) to neighboring networks and remote, offsite servers. The network manager is also responsible for providing an Internet connection to each mote. Data collected by the sensors can either be read directly by remote hosts, or stored on centralized servers for future access. With 20 such networks deployed in the American River, our system will comprise an unprecedented cyber-physical architecture for measuring hydrologic parameters in large-scale basins. The spatiotemporal density and real-time nature of the data is also expected to significantly improve operational hydrology and water resource

  7. Home visits by neighborhood Mentor Mothers provide timely recovery from childhood malnutrition in South Africa: results from a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Mbewu Nokwanele

    2010-11-01

    Full Text Available Abstract Background Child and infant malnourishment is a significant and growing problem in the developing world. Malnourished children are at high risk for negative health outcomes over their lifespans. Philani, a paraprofessional home visiting program, was developed to improve childhood nourishment. The objective of this study is to evaluate whether the Philani program can rehabilitate malnourished children in a timely manner. Methods Mentor Mothers were trained to conduct home visits. Mentor Mothers went from house to house in assigned neighborhoods, weighed children age 5 and younger, and recruited mother-child dyads where there was an underweight child. Participating dyads were assigned in a 2:1 random sequence to the Philani intervention condition (n = 536 or a control condition (n = 252. Mentor Mothers visited dyads in the intervention condition for one year, supporting mothers' problem-solving around nutrition. All children were weighed by Mentor Mothers at baseline and three, six, nine and twelve month follow-ups. Results By three months, children in the intervention condition were five times more likely to rehabilitate (reach a healthy weight for their ages than children in the control condition. Throughout the course of the study, 43% (n = 233 of 536 of children in the intervention condition were rehabilitated while 31% (n = 78 of 252 of children in the control condition were rehabilitated. Conclusions Paraprofessional Mentor Mothers are an effective strategy for delivering home visiting programs by providing the knowledge and support necessary to change the behavior of families at risk.

  8. An experimental study on providing a scientific evidence for seven-time alcohol-steaming of Rhei Rhizoma when clinically used.

    Science.gov (United States)

    Sim, Yeomoon; Oh, Hyein; Oh, Dal-Seok; Kim, Namkwon; Gu, Pil Sung; Choi, Jin Gyu; Kim, Hyo Geun; Kang, Tong Ho; Oh, Myung Sook

    2015-10-27

    Rhei Rhizoma (RR) has been widely used as laxative and processed to alter its therapeutic actions or reduce its side effects. In this study, we evaluated experimentally the clinical application guideline that RR should be alcohol-steamed seven times before being used in elderly patients, as described in Dongeuibogam, the most famous book on Korean traditional medicine. Unprocessed RR (RR-U) was soaked in rice wine, steamed and then fully dried (RR-P1). The process was repeated four (RR-P4) or seven times (RR-P7). Reversed-phase high-performance liquid chromatography was used to determine the RR-U, RR-P1, RR-P4 and RR-P7 (RRs) constituents. To evaluate the effect of RRs on liver toxicity, human hepatoma cells (HepG2) were treated with RRs at 100 μg/mL for 4 h and then cell viabilities were measured using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide method. To confirm the effects in vivo, 5-week-old male Sprague-Dawley rats were treated with RRs at 3 g/kg/day for 21 days. Body weight and serum biochemical parameters were measured and liver histology was assessed. The levels of sennosides decreased in processed RRs in an iteration-dependent manner, while the emodin level was unaffected. In HepG2 cells, cell viability was reduced with RR-U, while the toxicity decreased according to the number of processing cycles. The changes in body weight, relative liver weight and liver enzymes of RR-U-treated rats were reduced in processed RRs-treated rats. Histopathological analysis indicated swelling and cholestasis improved following seven times alcohol-steaming cycles. These results provide experimental evidence that RR-P7 almost completely reduces RR hepatotoxicity.

  9. Accurate determination of antenna directivity

    DEFF Research Database (Denmark)

    Dich, Mikael

    1997-01-01

    The derivation of a formula for accurate estimation of the total radiated power from a transmitting antenna for which the radiated power density is known in a finite number of points on the far-field sphere is presented. The main application of the formula is determination of directivity from power......-pattern measurements. The derivation is based on the theory of spherical wave expansion of electromagnetic fields, which also establishes a simple criterion for the required number of samples of the power density. An array antenna consisting of Hertzian dipoles is used to test the accuracy and rate of convergence...

  10. Presentations provided

    Energy Technology Data Exchange (ETDEWEB)

    Hashemian, H; Beverly, D [Analysis and Measurement Services Corp., Knoxville, TN (United States)

    1999-12-31

    The following topics covered in detail at the workshop included: temperature instrumentation; pressure instrumentation; in-situ calibration and response time testing of RTDs and pressure transmitters; on-line performance monitoring and preventive maintenance of critical equipment; automated measurement of critical parameters; nuclear power plant infrastructure, management and Quality Assurance issues and recent developments for WWER and RBMK reactors. Conclusions drawn were: aging can adversely affect the performance of nuclear plant pressure transmitters; current testing interval of once in every fuel cycle is adequate for aging management; in-situ response time measurements and on-line calibration testing methods have been developed and validated for nuclear plant pressure transmitters; NUREG/CR-5851 should be taken into account for details of aging research on pressure transmitters

  11. Presentations provided

    International Nuclear Information System (INIS)

    Hashemian, H.; Beverly, D.

    1998-01-01

    The following topics covered in detail at the workshop included: temperature instrumentation; pressure instrumentation; in-situ calibration and response time testing of RTDs and pressure transmitters; on-line performance monitoring and preventive maintenance of critical equipment; automated measurement of critical parameters; nuclear power plant infrastructure, management and Quality Assurance issues and recent developments for WWER and RBMK reactors. Conclusions drawn were: aging can adversely affect the performance of nuclear plant pressure transmitters; current testing interval of once in every fuel cycle is adequate for aging management; in-situ response time measurements and on-line calibration testing methods have been developed and validated for nuclear plant pressure transmitters; NUREG/CR-5851 should be taken into account for details of aging research on pressure transmitters

  12. Approaching system equilibrium with accurate or not accurate feedback information in a two-route system

    Science.gov (United States)

    Zhao, Xiao-mei; Xie, Dong-fan; Li, Qi

    2015-02-01

    With the development of intelligent transport system, advanced information feedback strategies have been developed to reduce traffic congestion and enhance the capacity. However, previous strategies provide accurate information to travelers and our simulation results show that accurate information brings negative effects, especially in delay case. Because travelers prefer to the best condition route with accurate information, and delayed information cannot reflect current traffic condition but past. Then travelers make wrong routing decisions, causing the decrease of the capacity and the increase of oscillations and the system deviating from the equilibrium. To avoid the negative effect, bounded rationality is taken into account by introducing a boundedly rational threshold BR. When difference between two routes is less than the BR, routes have equal probability to be chosen. The bounded rationality is helpful to improve the efficiency in terms of capacity, oscillation and the gap deviating from the system equilibrium.

  13. Finding the breech: Influence of breech presentation on mode of delivery based on timing of diagnosis, attempt at external cephalic version, and provider success with version.

    Science.gov (United States)

    Andrews, Suzanne; Leeman, Lawrence; Yonke, Nicole

    2017-09-01

    Breech presentation affects 3-4% of pregnancies at term and malpresentation is the primary indication for 10-15% of cesarean deliveries. External cephalic version is an effective intervention that can decrease the need for cesarean delivery; however, timely identification of breech presentation is required. We hypothesized that women with a fetus in a breech presentation that is diagnosed after 38 weeks' estimated gestational age have a decreased likelihood of external cephalic version attempted and an increased likelihood of cesarean delivery. This was a retrospective cohort study. A chart review was performed for 251 women with breech presentation at term presenting to our tertiary referral university hospital for external cephalic version, cesarean for breech presentation, or vaginal breech delivery. Vaginal delivery was significantly more likely (31.1% vs 12.5%; Pexternal cephalic version was offered, and subsequently attempted in a greater proportion of women diagnosed before 38 weeks. External cephalic version was more successful when performed by physicians with greater procedural volume during the 3.5 year period of the study (59.1% for providers performing at least 10 procedures vs 31.3% if performing fewer than 10 procedures, Pexternal cephalic version. © 2017 Wiley Periodicals, Inc.

  14. Accurate Modeling of Advanced Reflectarrays

    DEFF Research Database (Denmark)

    Zhou, Min

    to the conventional phase-only optimization technique (POT), the geometrical parameters of the array elements are directly optimized to fulfill the far-field requirements, thus maintaining a direct relation between optimization goals and optimization variables. As a result, better designs can be obtained compared...... of the incident field, the choice of basis functions, and the technique to calculate the far-field. Based on accurate reference measurements of two offset reflectarrays carried out at the DTU-ESA Spherical NearField Antenna Test Facility, it was concluded that the three latter factors are particularly important...... using the GDOT to demonstrate its capabilities. To verify the accuracy of the GDOT, two offset contoured beam reflectarrays that radiate a high-gain beam on a European coverage have been designed and manufactured, and subsequently measured at the DTU-ESA Spherical Near-Field Antenna Test Facility...

  15. Robust and accurate vectorization of line drawings.

    Science.gov (United States)

    Hilaire, Xavier; Tombre, Karl

    2006-06-01

    This paper presents a method for vectorizing the graphical parts of paper-based line drawings. The method consists of separating the input binary image into layers of homogeneous thickness, skeletonizing each layer, segmenting the skeleton by a method based on random sampling, and simplifying the result. The segmentation method is robust with a best bound of 50 percent noise reached for indefinitely long primitives. Accurate estimation of the recognized vector's parameters is enabled by explicitly computing their feasibility domains. Theoretical performance analysis and expression of the complexity of the segmentation method are derived. Experimental results and comparisons with other vectorization systems are also provided.

  16. Accurately controlled sequential self-folding structures by polystyrene film

    Science.gov (United States)

    Deng, Dongping; Yang, Yang; Chen, Yong; Lan, Xing; Tice, Jesse

    2017-08-01

    Four-dimensional (4D) printing overcomes the traditional fabrication limitations by designing heterogeneous materials to enable the printed structures evolve over time (the fourth dimension) under external stimuli. Here, we present a simple 4D printing of self-folding structures that can be sequentially and accurately folded. When heated above their glass transition temperature pre-strained polystyrene films shrink along the XY plane. In our process silver ink traces printed on the film are used to provide heat stimuli by conducting current to trigger the self-folding behavior. The parameters affecting the folding process are studied and discussed. Sequential folding and accurately controlled folding angles are achieved by using printed ink traces and angle lock design. Theoretical analyses are done to guide the design of the folding processes. Programmable structures such as a lock and a three-dimensional antenna are achieved to test the feasibility and potential applications of this method. These self-folding structures change their shapes after fabrication under controlled stimuli (electric current) and have potential applications in the fields of electronics, consumer devices, and robotics. Our design and fabrication method provides an easy way by using silver ink printed on polystyrene films to 4D print self-folding structures for electrically induced sequential folding with angular control.

  17. Circadian transitions in radiation dose-dependent augmentation of mRNA levels for DNA damage-induced genes elicited by accurate real-time RT-PCR quantification

    International Nuclear Information System (INIS)

    Ishihara, Hiroshi; Tanaka, Izumi; Yakumaru, Haruko

    2010-01-01

    Molecular mechanisms of intracellular response after DNA-damage by exposure to ionizing radiation have been studied. In the case of cells isolated from living body of human and experimental animals, alteration of the responsiveness by physiological oscillation such as circadian rhythm must be considered. To examine the circadian variation in the response of p53-responsible genes p21, mdm2, bax, and puma, we established a method to quantitate their mRNA levels with high reproducibility and accuracy based on real-time reverse transcription polymerase chain reaction (RT-PCR) and compared the levels of responsiveness in mouse hemocytes after diurnal irradiation to that after nocturnal irradiation. Augmentations of p21 and mdm2 mRNA levels with growth-arrest and of puma mRNA before apoptosis were confirmed by time-course experiment in RAW264.7, and dose-dependent increases in the peak levels of all the RNA were shown. Similarly, the relative RNA levels of p21, mdm2, bax, and puma per glyceraldehyde-3-phosphate dehydrogenase (GAPDH) also increased dose-dependently in peripheral blood and bone marrow cells isolated from whole-body-irradiated mice. Induction levels of all messages reduced by half after nighttime irradiation as compared with daytime irradiation in blood cells. In marrow cells, nighttime irradiation enhanced the p21 and mdm2 mRNA levels than daytime irradiation. No significant difference in bax or puma mRNA levels was observed between nighttime and daytime irradiation in marrow cells. This suggests that early-stage cellular responsiveness in DNA damage-induced genes is modulated between diurnal and nocturnal irradiation. (author)

  18. Accurate Alignment of Plasma Channels Based on Laser Centroid Oscillations

    International Nuclear Information System (INIS)

    Gonsalves, Anthony; Nakamura, Kei; Lin, Chen; Osterhoff, Jens; Shiraishi, Satomi; Schroeder, Carl; Geddes, Cameron; Toth, Csaba; Esarey, Eric; Leemans, Wim

    2011-01-01

    A technique has been developed to accurately align a laser beam through a plasma channel by minimizing the shift in laser centroid and angle at the channel outptut. If only the shift in centroid or angle is measured, then accurate alignment is provided by minimizing laser centroid motion at the channel exit as the channel properties are scanned. The improvement in alignment accuracy provided by this technique is important for minimizing electron beam pointing errors in laser plasma accelerators.

  19. Evaluation of the role of access providers. Discussion of Dutch Pirate Bay case law and introducing principles on directness, effectiveness, costs, relevance, and time

    NARCIS (Netherlands)

    Lodder, A.R.; van der Meulen, N.S.

    2013-01-01

    Internet service providers (ISPs) play a pivotal role in contemporary society because they provide access to the Internet. The primary task of ISPs – to blindly transfer information across the network – has recently come under pressure, as has their status as neutral third parties. Both the public

  20. A New Sulfur and Carbon Degassing Inventory for the Southern Central American Volcanic Arc: The Importance of Accurate Time-Series Data Sets and Possible Tectonic Processes Responsible for Temporal Variations in Arc-Scale Volatile Emissions

    Science.gov (United States)

    de Moor, J. M.; Kern, C.; Avard, G.; Muller, C.; Aiuppa, A.; Saballos, A.; Ibarra, M.; LaFemina, P.; Protti, M.; Fischer, T. P.

    2017-12-01

    This work presents a new database of SO2 and CO2 fluxes from the Southern Central American Volcanic Arc (SCAVA) for the period 2015-2016. We report ˜300 SO2 flux measurements from 10 volcanoes and gas ratios from 11 volcanoes in Costa Rica and Nicaragua representing the most extensive available assessment of this ˜500 km arc segment. The SO2 flux from SCAVA is estimated at 6,240 ± 1,150 T/d, about a factor of three higher than previous estimations (1972-2013). We attribute this increase in part to our more complete assessment of the arc. Another consideration in interpreting the difference is the context of increased volcanic activity, as there were more eruptions in 2015-2016 than in any period since ˜1980. A potential explanation for increased degassing and volcanic activity is a change in crustal stress regime (from compression to extension, opening volcanic conduits) following two large (Mw > 7) earthquakes in the region in 2012. The CO2 flux from the arc is estimated at 22,500 ± 4,900 T/d, which is equal to or greater than estimates of C input into the SCAVA subduction zone. Time-series data sets for arc degassing need to be improved in temporal and spatial coverage to robustly constrain volatile budgets and tectonic controls. Arc volatile budgets are strongly influenced by short-lived degassing events and arc systems likely display significant short-term variations in volatile output, calling for expansion of nascent geochemical monitoring networks to achieve spatial and temporal coverage similar to traditional geophysical networks.

  1. "The care is the best you can give at the time": Health care professionals' experiences in providing gender affirming care in South Africa.

    Directory of Open Access Journals (Sweden)

    Sarah Spencer

    Full Text Available While the provision of gender affirming care for transgender people in South Africa is considered legal, ethical, and medically sound, and is-theoretically-available in both the South African private and public health sectors, access remains severely limited and unequal within the country. As there are no national policies or guidelines, little is known about how individual health care professionals providing gender affirming care make clinical decisions about eligibility and treatment options.Based on an initial policy review and service mapping, this study employed semi-structured interviews with a snowball sample of twelve health care providers, representing most providers currently providing gender affirming care in South Africa. Data were analysed thematically using NVivo, and are reported following COREQ guidelines.Our findings suggest that, whilst a small minority of health care providers offer gender affirming care, this is almost exclusively on their own initiative and is usually unsupported by wider structures and institutions. The ad hoc, discretionary nature of services means that access to care is dependent on whether a transgender person is fortunate enough to access a sympathetic and knowledgeable health care provider.Accordingly, national, state-sanctioned guidelines for gender affirming care are necessary to increase access, homogenise quality of care, and contribute to equitable provision of gender affirming care in the public and private health systems.

  2. Do Native American Culture, Life Experiences, Physics and the Bible Provide Supportive Evidence For Julian Barbour's Thesis About Anachronisms Relating to The End of Time?

    Science.gov (United States)

    Mears, Paul C.; Mc Leod, Roger D.

    2002-10-01

    Historic, and current Native American attitude considers that time can be considered in a cyclic sense that contrasts against a majority view of physicists that time varies in a linear algebraic sense. Precognition experiences offer evidence that time has a more subtle substance. The Bible clearly delineates "prophetic awareness of the future." Embedded "Bible codes" are touted as mathematical evidence for the existence of God. His existence is better served if "past-tense" information of events can propagate backward relative to our "present-tense" time. Barbour, p39: [some] " physicists entertain the idea time truly does not exist applies to motion .suggestion; it too is pure illusion." The concept of prophecy has been interpreted as evidence or "proof" of the existence of "Manitou" or God. Our interpretation is that, according to Native American legends, or the Bible, for as yet unspecified reasons, time behaves as though it can convey information in a backward, or forward, sense. It is like an f (t ± ti).

  3. Sex-Specific Arrival Times on the Breeding Grounds: Hybridizing Migratory Skuas Provide Empirical Support for the Role of Sex Ratios.

    Science.gov (United States)

    Lisovski, Simeon; Fröhlich, Anne; von Tersch, Matthew; Klaassen, Marcel; Peter, Hans-Ulrich; Ritz, Markus S

    2016-04-01

    In migratory animals, protandry (earlier arrival of males on the breeding grounds) prevails over protogyny (females preceding males). In theory, sex differences in timing of arrival should be driven by the operational sex ratio, shifting toward protogyny in female-biased populations. However, empirical support for this hypothesis is, to date, lacking. To test this hypothesis, we analyzed arrival data from three populations of the long-distance migratory south polar skua (Catharacta maccormicki). These populations differed in their operational sex ratio caused by the unidirectional hybridization of male south polar skuas with female brown skuas (Catharacta antarctica lonnbergi). We found that arrival times were protandrous in allopatry, shifting toward protogyny in female-biased populations when breeding in sympatry. This unique observation is consistent with theoretical predictions that sex-specific arrival times should be influenced by sex ratio and that protogyny should be observed in populations with female-biased operational sex ratio.

  4. Accurate shear measurement with faint sources

    International Nuclear Information System (INIS)

    Zhang, Jun; Foucaud, Sebastien; Luo, Wentao

    2015-01-01

    For cosmic shear to become an accurate cosmological probe, systematic errors in the shear measurement method must be unambiguously identified and corrected for. Previous work of this series has demonstrated that cosmic shears can be measured accurately in Fourier space in the presence of background noise and finite pixel size, without assumptions on the morphologies of galaxy and PSF. The remaining major source of error is source Poisson noise, due to the finiteness of source photon number. This problem is particularly important for faint galaxies in space-based weak lensing measurements, and for ground-based images of short exposure times. In this work, we propose a simple and rigorous way of removing the shear bias from the source Poisson noise. Our noise treatment can be generalized for images made of multiple exposures through MultiDrizzle. This is demonstrated with the SDSS and COSMOS/ACS data. With a large ensemble of mock galaxy images of unrestricted morphologies, we show that our shear measurement method can achieve sub-percent level accuracy even for images of signal-to-noise ratio less than 5 in general, making it the most promising technique for cosmic shear measurement in the ongoing and upcoming large scale galaxy surveys

  5. How Accurately can we Calculate Thermal Systems?

    International Nuclear Information System (INIS)

    Cullen, D; Blomquist, R N; Dean, C; Heinrichs, D; Kalugin, M A; Lee, M; Lee, Y; MacFarlan, R; Nagaya, Y; Trkov, A

    2004-01-01

    I would like to determine how accurately a variety of neutron transport code packages (code and cross section libraries) can calculate simple integral parameters, such as K eff , for systems that are sensitive to thermal neutron scattering. Since we will only consider theoretical systems, we cannot really determine absolute accuracy compared to any real system. Therefore rather than accuracy, it would be more precise to say that I would like to determine the spread in answers that we obtain from a variety of code packages. This spread should serve as an excellent indicator of how accurately we can really model and calculate such systems today. Hopefully, eventually this will lead to improvements in both our codes and the thermal scattering models that they use in the future. In order to accomplish this I propose a number of extremely simple systems that involve thermal neutron scattering that can be easily modeled and calculated by a variety of neutron transport codes. These are theoretical systems designed to emphasize the effects of thermal scattering, since that is what we are interested in studying. I have attempted to keep these systems very simple, and yet at the same time they include most, if not all, of the important thermal scattering effects encountered in a large, water-moderated, uranium fueled thermal system, i.e., our typical thermal reactors

  6. Bogoch Replikins Pandemic Prevention: Increase of Strain-Specific Influenza Genomic Replikin Counts, Having Predicted Outbreaks and their Location Seven Times Consecutively, Up to Two Years in Advance, Provides Time for Prevention of Pandemics

    OpenAIRE

    Samuel Bogoch; Elenore S. Bogoch

    2012-01-01

    Earlier studies have shown that the increased concentration of a new class of virus genomic peptides, Replikins, precedes and predicts virus outbreaks. We now find that the area in the genome of the highest concentration of Replikins, and the country in which this peak exists in scout viruses, have permitted in the past five years seven consecutive accurate predictions of the geographic localization of coming outbreaks, including those now realized in Mexico for H1N1, and in Cambodia for H5N1...

  7. ListeningTime; participatory development of a web-based preparatory communication tool for elderly cancer patients and their healthcare providers.

    NARCIS (Netherlands)

    Noordman, J.; Driesenaar, J.A.; Bruinessen, I.R. van; Dulmen, S. van

    2017-01-01

    Objective: This paper outlines the participatory development process of a web-based preparatory communication tool for elderly cancer patients and their oncological healthcare providers (HCPs). This tool aims to support them to (better) prepare their encounters. An overarching aim of the project is

  8. Zadoff-Chu coded ultrasonic signal for accurate range estimation

    KAUST Repository

    AlSharif, Mohammed H.

    2017-11-02

    This paper presents a new adaptation of Zadoff-Chu sequences for the purpose of range estimation and movement tracking. The proposed method uses Zadoff-Chu sequences utilizing a wideband ultrasonic signal to estimate the range between two devices with very high accuracy and high update rate. This range estimation method is based on time of flight (TOF) estimation using cyclic cross correlation. The system was experimentally evaluated under different noise levels and multi-user interference scenarios. For a single user, the results show less than 7 mm error for 90% of range estimates in a typical indoor environment. Under the interference from three other users, the 90% error was less than 25 mm. The system provides high estimation update rate allowing accurate tracking of objects moving with high speed.

  9. Fast and accurate automated cell boundary determination for fluorescence microscopy

    Science.gov (United States)

    Arce, Stephen Hugo; Wu, Pei-Hsun; Tseng, Yiider

    2013-07-01

    Detailed measurement of cell phenotype information from digital fluorescence images has the potential to greatly advance biomedicine in various disciplines such as patient diagnostics or drug screening. Yet, the complexity of cell conformations presents a major barrier preventing effective determination of cell boundaries, and introduces measurement error that propagates throughout subsequent assessment of cellular parameters and statistical analysis. State-of-the-art image segmentation techniques that require user-interaction, prolonged computation time and specialized training cannot adequately provide the support for high content platforms, which often sacrifice resolution to foster the speedy collection of massive amounts of cellular data. This work introduces a strategy that allows us to rapidly obtain accurate cell boundaries from digital fluorescent images in an automated format. Hence, this new method has broad applicability to promote biotechnology.

  10. Zadoff-Chu coded ultrasonic signal for accurate range estimation

    KAUST Repository

    AlSharif, Mohammed H.; Saad, Mohamed; Siala, Mohamed; Ballal, Tarig; Boujemaa, Hatem; Al-Naffouri, Tareq Y.

    2017-01-01

    This paper presents a new adaptation of Zadoff-Chu sequences for the purpose of range estimation and movement tracking. The proposed method uses Zadoff-Chu sequences utilizing a wideband ultrasonic signal to estimate the range between two devices with very high accuracy and high update rate. This range estimation method is based on time of flight (TOF) estimation using cyclic cross correlation. The system was experimentally evaluated under different noise levels and multi-user interference scenarios. For a single user, the results show less than 7 mm error for 90% of range estimates in a typical indoor environment. Under the interference from three other users, the 90% error was less than 25 mm. The system provides high estimation update rate allowing accurate tracking of objects moving with high speed.

  11. Evaluating Teachers' Support Requests When Just-in-Time Instructional Support is Provided to Introduce a Primary Level Web-Based Reading Program

    Science.gov (United States)

    Wood, Eileen; Anderson, Alissa; Piquette-Tomei, Noella; Savage, Robert; Mueller, Julie

    2011-01-01

    Support requests were documented for 10 teachers (4 kindergarten, 4 grade one, and 2 grade one/two teachers) who received just-in-time instructional support over a 2 1/2 month period while implementing a novel reading software program as part of their literacy instruction. In-class observations were made of each instructional session. Analysis of…

  12. The Effect of the Transition to Home Monitoring for the Diagnosis of OSAS on Test Availability, Waiting Time, Patients’ Satisfaction, and Outcome in a Large Health Provider System

    Directory of Open Access Journals (Sweden)

    Ahmad Safadi

    2014-01-01

    Full Text Available During 2009, the Haifa district of Clalit Health Services (CHS has switched from in-lab polysomnography (PSG to home studies for the diagnosis of obstructive sleep apnea (OSA. We assessed the effects of this change on accessibility, waiting time, satisfaction, costs, and CPAP purchase by the patients. Data regarding sleep studies, CPAP purchase, and waiting times were collected retrospectively from the computerized database of CHS. Patients’ satisfaction was assessed utilizing a telephone questionnaire introduced to a randomized small sample of 70 patients. Comparisons were made between 2007 and 2008 (in-lab PSGs and 2010 and 2011 (when most studies were ambulatory. Of about 650000 insured individuals in the Haifa district of CHS, 1471 sleep studies were performed during 2007-2008 compared to 2794 tests during 2010-2011. The average waiting time was 9.9 weeks in 2007-2008 compared to 1.1 weeks in 2010-2011 (P<0.05. 597 CPAPs were purchased in 2007-2008 compared to 831 in 2010-2011. The overall patients’ satisfaction was similar, but discomfort tended to be higher in the in-laboratory group (4.1 vs 2.7 in a scale of 0–10; P=0.11. Switching to ambulatory diagnosis improved the test accessibility and reduced the waiting times. Patients’ satisfaction remained similarly high. The total direct cost of OSA management was reduced.

  13. Accurate computation of Mathieu functions

    CERN Document Server

    Bibby, Malcolm M

    2013-01-01

    This lecture presents a modern approach for the computation of Mathieu functions. These functions find application in boundary value analysis such as electromagnetic scattering from elliptic cylinders and flat strips, as well as the analogous acoustic and optical problems, and many other applications in science and engineering. The authors review the traditional approach used for these functions, show its limitations, and provide an alternative ""tuned"" approach enabling improved accuracy and convergence. The performance of this approach is investigated for a wide range of parameters and mach

  14. Detecting Cancer Quickly and Accurately

    Science.gov (United States)

    Gourley, Paul; McDonald, Anthony; Hendricks, Judy; Copeland, Guild; Hunter, John; Akhil, Ohmar; Capps, Heather; Curry, Marc; Skirboll, Steve

    2000-03-01

    We present a new technique for high throughput screening of tumor cells in a sensitive nanodevice that has the potential to quickly identify a cell population that has begun the rapid protein synthesis and mitosis characteristic of cancer cell proliferation. Currently, pathologists rely on microscopic examination of cell morphology using century-old staining methods that are labor-intensive, time-consuming and frequently in error. New micro-analytical methods for automated, real time screening without chemical modification are critically needed to advance pathology and improve diagnoses. We have teamed scientists with physicians to create a microlaser biochip (based upon our R&D award winning bio-laser concept)1 which evaluates tumor cells by quantifying their growth kinetics. The key new discovery was demonstrating that the lasing spectra are sensitive to the biomolecular mass in the cell, which changes the speed of light in the laser microcavity. Initial results with normal and cancerous human brain cells show that only a few hundred cells -- the equivalent of a billionth of a liter -- are required to detect abnormal growth. The ability to detect cancer in such a minute tissue sample is crucial for resecting a tumor margin or grading highly localized tumor malignancy. 1. P. L. Gourley, NanoLasers, Scientific American, March 1998, pp. 56-61. This work supported under DOE contract DE-AC04-94AL85000 and the Office of Basic Energy Sciences.

  15. Quantitative estimation of cholinesterase-specific drug metabolism of carbamate inhibitors provided by the analysis of the area under the inhibition-time curve.

    Science.gov (United States)

    Zhou, Huimin; Xiao, Qiaoling; Tan, Wen; Zhan, Yiyi; Pistolozzi, Marco

    2017-09-10

    Several molecules containing carbamate groups are metabolized by cholinesterases. This metabolism includes a time-dependent catalytic step which temporary inhibits the enzymes. In this paper we demonstrate that the analysis of the area under the inhibition versus time curve (AUIC) can be used to obtain a quantitative estimation of the amount of carbamate metabolized by the enzyme. (R)-bambuterol monocarbamate and plasma butyrylcholinesterase were used as model carbamate-cholinesterase system. The inhibition of different concentrations of the enzyme was monitored for 5h upon incubation with different concentrations of carbamate and the resulting AUICs were analyzed. The amount of carbamate metabolized could be estimated with cholinesterases in a selected compartment in which the cholinesterase is confined (e.g. in vitro solutions, tissues or body fluids), either in vitro or in vivo. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Centi-pixel accurate real-time inverse distortion correction

    CSIR Research Space (South Africa)

    De Villiers, Johan P

    2008-11-01

    Full Text Available Inverse distortion is used to create an undistorted image from a distorted image. For each pixel in the undistorted image it is required to determine which pixel in the distorted image should be used. However the process of characterizing a lens...

  17. The Most Likely Nemesis to Timely, Accurate Electronic Information

    Science.gov (United States)

    2002-02-04

    NETWORKS, TRAINING, COMMERCIAL OFF-THE-SHELF, INFORMATION TECHNOLOGY , INTERNET , COMMUNICATIONS EQUIPMENT, ELECTRONIC INFORMATION 15.Abstract...infected over 200,000 Internet computers . While the objective appeared to be to create a log-jam on the Internet and not actually alter information on...Brigadier General Robert M. Shea, USMC, Director for Command, Control, Communications and Computers for the Marine Corps, cites information overload problems

  18. Selection of population controls for a Salmonella case-control study in the UK using a market research panel and web-survey provides time and resource savings.

    Science.gov (United States)

    Mook, P; Kanagarajah, S; Maguire, H; Adak, G K; Dabrera, G; Waldram, A; Freeman, R; Charlett, A; Oliver, I

    2016-04-01

    Timely recruitment of population controls in infectious disease outbreak investigations is challenging. We evaluated the timeliness and cost of using a market research panel as a sampling frame for recruiting controls in a case-control study during an outbreak of Salmonella Mikawasima in the UK in 2013. We deployed a web-survey by email to targeted members of a market research panel (panel controls) in parallel to the outbreak control team interviewing randomly selected public health staff by telephone and completing paper-based questionnaires (staff controls). Recruitment and completion of exposure history web-surveys for panel controls (n = 123) took 14 h compared to 15 days for staff controls (n = 82). The average staff-time cost per questionnaire for staff controls was £13·13 compared to an invoiced cost of £3·60 per panel control. Differences in the distribution of some exposures existed between these control groups but case-control studies using each group found that illness was associated with consumption of chicken outside of the home and chicken from local butchers. Recruiting market research panel controls offers time and resource savings. More rapid investigations would enable more prompt implementation of control measures. We recommend that this method of recruiting controls is considered in future investigations and assessed further to better understand strengths and limitations.

  19. Accurate metacognition for visual sensory memory representations.

    Science.gov (United States)

    Vandenbroucke, Annelinde R E; Sligte, Ilja G; Barrett, Adam B; Seth, Anil K; Fahrenfort, Johannes J; Lamme, Victor A F

    2014-04-01

    The capacity to attend to multiple objects in the visual field is limited. However, introspectively, people feel that they see the whole visual world at once. Some scholars suggest that this introspective feeling is based on short-lived sensory memory representations, whereas others argue that the feeling of seeing more than can be attended to is illusory. Here, we investigated this phenomenon by combining objective memory performance with subjective confidence ratings during a change-detection task. This allowed us to compute a measure of metacognition--the degree of knowledge that subjects have about the correctness of their decisions--for different stages of memory. We show that subjects store more objects in sensory memory than they can attend to but, at the same time, have similar metacognition for sensory memory and working memory representations. This suggests that these subjective impressions are not an illusion but accurate reflections of the richness of visual perception.

  20. An accurate nonlinear Monte Carlo collision operator

    International Nuclear Information System (INIS)

    Wang, W.X.; Okamoto, M.; Nakajima, N.; Murakami, S.

    1995-03-01

    A three dimensional nonlinear Monte Carlo collision model is developed based on Coulomb binary collisions with the emphasis both on the accuracy and implementation efficiency. The operator of simple form fulfills particle number, momentum and energy conservation laws, and is equivalent to exact Fokker-Planck operator by correctly reproducing the friction coefficient and diffusion tensor, in addition, can effectively assure small-angle collisions with a binary scattering angle distributed in a limited range near zero. Two highly vectorizable algorithms are designed for its fast implementation. Various test simulations regarding relaxation processes, electrical conductivity, etc. are carried out in velocity space. The test results, which is in good agreement with theory, and timing results on vector computers show that it is practically applicable. The operator may be used for accurately simulating collisional transport problems in magnetized and unmagnetized plasmas. (author)

  1. High Availability Applications for NOMADS at the NOAA Web Operations Center Aimed at Providing Reliable Real Time Access to Operational Model Data

    Science.gov (United States)

    Alpert, J. C.; Rutledge, G.; Wang, J.; Freeman, P.; Kang, C. Y.

    2009-05-01

    The NOAA Operational Modeling Archive Distribution System (NOMADS) is now delivering high availability services as part of NOAA's official real time data dissemination at its Web Operations Center (WOC). The WOC is a web service used by all organizational units in NOAA and acts as a data repository where public information can be posted to a secure and scalable content server. A goal is to foster collaborations among the research and education communities, value added retailers, and public access for science and development efforts aimed at advancing modeling and GEO-related tasks. The services used to access the operational model data output are the Open-source Project for a Network Data Access Protocol (OPeNDAP), implemented with the Grid Analysis and Display System (GrADS) Data Server (GDS), and applications for slicing, dicing and area sub-setting the large matrix of real time model data holdings. This approach insures an efficient use of computer resources because users transmit/receive only the data necessary for their tasks including metadata. Data sets served in this way with a high availability server offer vast possibilities for the creation of new products for value added retailers and the scientific community. New applications to access data and observations for verification of gridded model output, and progress toward integration with access to conventional and non-conventional observations will be discussed. We will demonstrate how users can use NOMADS services to repackage area subsets either using repackaging of GRIB2 files, or values selected by ensemble component, (forecast) time, vertical levels, global horizontal location, and by variable, virtually a 6- Dimensional analysis services across the internet.

  2. Prediction of Accurate Mixed Mode Fatigue Crack Growth Curves using the Paris' Law

    Science.gov (United States)

    Sajith, S.; Krishna Murthy, K. S. R.; Robi, P. S.

    2017-12-01

    Accurate information regarding crack growth times and structural strength as a function of the crack size is mandatory in damage tolerance analysis. Various equivalent stress intensity factor (SIF) models are available for prediction of mixed mode fatigue life using the Paris' law. In the present investigation these models have been compared to assess their efficacy in prediction of the life close to the experimental findings as there are no guidelines/suggestions available on selection of these models for accurate and/or conservative predictions of fatigue life. Within the limitations of availability of experimental data and currently available numerical simulation techniques, the results of present study attempts to outline models that would provide accurate and conservative life predictions.

  3. Accurate measurement of indoor radon concentration using a low-effective volume radon monitor

    International Nuclear Information System (INIS)

    Tanaka, Aya; Minami, Nodoka; Mukai, Takahiro; Yasuoka, Yumi; Iimoto, Takeshi; Omori, Yasutaka; Nagahama, Hiroyuki; Muto, Jun

    2017-01-01

    AlphaGUARD is a low-effective volume detector and one of the most popular portable radon monitors which is currently available. This study investigated whether AlphaGUARD can accurately measure the variable indoor radon levels. The consistency of the radon-concentration data obtained by AlphaGUARD is evaluated against simultaneous measurements by two other monitors (each ∼10 times more sensitive than AlphaGUARD). When accurately measuring radon concentration with AlphaGUARD, we found that the net counts of the AlphaGUARD were required of at least 500 counts, <25% of the relative percent difference. AlphaGUARD can provide accurate measurements of radon concentration for the world average level (∼50 Bq m -3 ) and the reference level of workplace (1000 Bq m -3 ), using integrated data over at least 3 h and 10 min, respectively. (authors)

  4. Spectrally accurate initial data in numerical relativity

    Science.gov (United States)

    Battista, Nicholas A.

    Einstein's theory of general relativity has radically altered the way in which we perceive the universe. His breakthrough was to realize that the fabric of space is deformable in the presence of mass, and that space and time are linked into a continuum. Much evidence has been gathered in support of general relativity over the decades. Some of the indirect evidence for GR includes the phenomenon of gravitational lensing, the anomalous perihelion of mercury, and the gravitational redshift. One of the most striking predictions of GR, that has not yet been confirmed, is the existence of gravitational waves. The primary source of gravitational waves in the universe is thought to be produced during the merger of binary black hole systems, or by binary neutron stars. The starting point for computer simulations of black hole mergers requires highly accurate initial data for the space-time metric and for the curvature. The equations describing the initial space-time around the black hole(s) are non-linear, elliptic partial differential equations (PDE). We will discuss how to use a pseudo-spectral (collocation) method to calculate the initial puncture data corresponding to single black hole and binary black hole systems.

  5. Getting It Right the First Time: Defining Regionally Relevant Training Curricula and Provider Core Competencies for Point-of-Care Ultrasound Education on the African Continent.

    Science.gov (United States)

    Salmon, Margaret; Landes, Megan; Hunchak, Cheryl; Paluku, Justin; Malemo Kalisya, Luc; Salmon, Christian; Muller, Mundenga Mutendi; Wachira, Benjamin; Mangan, James; Chhaganlal, Kajal; Kalanzi, Joseph; Azazh, Aklilu; Berman, Sara; Zied, El-Sayed; Lamprecht, Hein

    2017-02-01

    Significant evidence identifies point-of-care ultrasound (PoCUS) as an important diagnostic and therapeutic tool in resource-limited settings. Despite this evidence, local health care providers on the African continent continue to have limited access to and use of ultrasound, even in potentially high-impact fields such as obstetrics and trauma. Dedicated postgraduate emergency medicine residency training programs now exist in 8 countries, yet no current consensus exists in regard to core PoCUS competencies. The current practice of transferring resource-rich PoCUS curricula and delivery methods to resource-limited health systems fails to acknowledge the unique challenges, needs, and disease burdens of recipient systems. As emergency medicine leaders from 8 African countries, we introduce a practical algorithmic approach, based on the local epidemiology and resource constraints, to curriculum development and implementation. We describe an organizational structure composed of nexus learning centers for PoCUS learners and champions on the continent to keep credentialing rigorous and standardized. Finally, we put forth 5 key strategic considerations: to link training programs to hospital systems, to prioritize longitudinal learning models, to share resources to promote health equity, to maximize access, and to develop a regional consensus on training standards and credentialing. Copyright © 2016 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  6. On the accurate fast evaluation of finite Fourier integrals using cubic splines

    International Nuclear Information System (INIS)

    Morishima, N.

    1993-01-01

    Finite Fourier integrals based on a cubic-splines fit to equidistant data are shown to be evaluated fast and accurately. Good performance, especially on computational speed, is achieved by the optimization of the spline fit and the internal use of the fast Fourier transform (FFT) algorithm for complex data. The present procedure provides high accuracy with much shorter CPU time than a trapezoidal FFT. (author)

  7. A method for an accurate in-flight calibration of AVHRR data for vegetation index calculation

    OpenAIRE

    Asmami , Mbarek; Wald , Lucien

    1992-01-01

    International audience; A significant degradation in the Advanced Very High Resolution Radiometer (AVHRR) responsitivity, on the NOAA satellite series, has occurred since the prelaunch calibration and with time since launch. This affects the index vegetation (NDVI), which is an important source of information for monitoring vegetation conditions on regional and global scales. Many studies have been carried out which use the Viewing Earth calibration approach in order to provide accurate calib...

  8. Impact of new healthcare legislation and price policy on healthcare services provider at the time of financial crisis. A 10 years study

    Directory of Open Access Journals (Sweden)

    Ivona Malovecka

    2015-03-01

    Full Text Available Monitoring, calculation and assessment of healthcare services prosperity in the community pharmacy with the help of financial analysis indicators for the years 2003-2012, using financial statements was conducted, with respect to profitability, debt, liquidity, working capital, and efficiency parameters. These ratios reflect various changes that hold between years 2003 and 2012. Under the time of financial crisis, recession and serious socio-economic changes the profitability parameter Gross Profit ranged from 2003-2011 = 16.12-22.79% (average = 19.20%; mean = 19.78%; σ = 2.41, but in 2012 decreased on 14.35%. Net Profit ranged 2003-2011 = 10.96-18.3% (average = 14.62%; mean = 16.62%; σ = 4.92, while in 2012 reached only 2.29%. Debt ratio ranged from 2003-2012= 2.33-4.81 (average = 3.44; mean = 3.07; σ = 0.82. Liquidity parameters Current Ratio spread between 2003-2012 = 1.13-1.71 (average = 1.43; mean = 1.46; σ = 0.15 and Quick Ratio spread between 2003-2012 = 0.72-1.27 (average = 1.07; mean = 1.09; σ = 0.15. Working Capital Ratio ranged from 2003-2012 = 2.66-12.94 (average = 9.58; mean = 10.06; σ = 3.1 and efficiency ratios were measured either. All changes that have taken place in the society had an impact on community pharmacy finance by worsening its profitability, liquidity, working capital and some of efficiency parameters. Therefore the stability of community pharmacy may be threatened and may affect its future performance.http://dx.doi.org/10.7175/fe.v16i1.1040

  9. Electric Substations, Electric substation locations provided to us from Kansas City Power and Light and City of Gardner only at this time. AIMS is working on getting other providers in area. Data is limited to CUE (Collaborative Utility Exchange) Participants and subcontracto, Published in 2004, Johnson County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Electric Substations dataset current as of 2004. Electric substation locations provided to us from Kansas City Power and Light and City of Gardner only at this time....

  10. The KFM, A Homemade Yet Accurate and Dependable Fallout Meter

    Energy Technology Data Exchange (ETDEWEB)

    Kearny, C.H.

    2001-11-20

    The KFM is a homemade fallout meter that can be made using only materials, tools, and skills found in millions of American homes. It is an accurate and dependable electroscope-capacitor. The KFM, in conjunction with its attached table and a watch, is designed for use as a rate meter. Its attached table relates observed differences in the separations of its two leaves (before and after exposures at the listed time intervals) to the dose rates during exposures of these time intervals. In this manner dose rates from 30 mR/hr up to 43 R/hr can be determined with an accuracy of {+-}25%. A KFM can be charged with any one of the three expedient electrostatic charging devices described. Due to the use of anhydrite (made by heating gypsum from wallboard) inside a KFM and the expedient ''dry-bucket'' in which it can be charged when the air is very humid, this instrument always can be charged and used to obtain accurate measurements of gamma radiation no matter how high the relative humidity. The heart of this report is the step-by-step illustrated instructions for making and using a KFM. These instructions have been improved after each successive field test. The majority of the untrained test families, adequately motivated by cash bonuses offered for success and guided only by these written instructions, have succeeded in making and using a KFM. NOTE: ''The KFM, A Homemade Yet Accurate and Dependable Fallout Meter'', was published by Oak Ridge National Laboratory report in1979. Some of the materials originally suggested for suspending the leaves of the Kearny Fallout Meter (KFM) are no longer available. Because of changes in the manufacturing process, other materials (e.g., sewing thread, unwaxed dental floss) may not have the insulating capability to work properly. Oak Ridge National Laboratory has not tested any of the suggestions provided in the preface of the report, but they have been used by other groups. When using these

  11. Gardening Provides Valuable Time to Talk

    Science.gov (United States)

    Boyd, Margaret

    2016-01-01

    Like many schools, Hornsea Community Primary School, which is situated in a rural coastal town in East Yorkshire, has a long wish list of both curriculum and pastoral ideals. A gardening club was started at the school with the intention of transforming two small areas of the school grounds that were very visible to the school community and to…

  12. Accurate fluid force measurement based on control surface integration

    Science.gov (United States)

    Lentink, David

    2018-01-01

    Nonintrusive 3D fluid force measurements are still challenging to conduct accurately for freely moving animals, vehicles, and deforming objects. Two techniques, 3D particle image velocimetry (PIV) and a new technique, the aerodynamic force platform (AFP), address this. Both rely on the control volume integral for momentum; whereas PIV requires numerical integration of flow fields, the AFP performs the integration mechanically based on rigid walls that form the control surface. The accuracy of both PIV and AFP measurements based on the control surface integration is thought to hinge on determining the unsteady body force associated with the acceleration of the volume of displaced fluid. Here, I introduce a set of non-dimensional error ratios to show which fluid and body parameters make the error negligible. The unsteady body force is insignificant in all conditions where the average density of the body is much greater than the density of the fluid, e.g., in gas. Whenever a strongly deforming body experiences significant buoyancy and acceleration, the error is significant. Remarkably, this error can be entirely corrected for with an exact factor provided that the body has a sufficiently homogenous density or acceleration distribution, which is common in liquids. The correction factor for omitting the unsteady body force, {{{ {ρ f}} {1 - {ρ f} ( {{ρ b}+{ρ f}} )}.{( {{{{ρ }}b}+{ρ f}} )}}} , depends only on the fluid, {ρ f}, and body, {{ρ }}b, density. Whereas these straightforward solutions work even at the liquid-gas interface in a significant number of cases, they do not work for generalized bodies undergoing buoyancy in combination with appreciable body density inhomogeneity, volume change (PIV), or volume rate-of-change (PIV and AFP). In these less common cases, the 3D body shape needs to be measured and resolved in time and space to estimate the unsteady body force. The analysis shows that accounting for the unsteady body force is straightforward to non

  13. Accurate mass and velocity functions of dark matter haloes

    Science.gov (United States)

    Comparat, Johan; Prada, Francisco; Yepes, Gustavo; Klypin, Anatoly

    2017-08-01

    N-body cosmological simulations are an essential tool to understand the observed distribution of galaxies. We use the MultiDark simulation suite, run with the Planck cosmological parameters, to revisit the mass and velocity functions. At redshift z = 0, the simulations cover four orders of magnitude in halo mass from ˜1011M⊙ with 8783 874 distinct haloes and 532 533 subhaloes. The total volume used is ˜515 Gpc3, more than eight times larger than in previous studies. We measure and model the halo mass function, its covariance matrix w.r.t halo mass and the large-scale halo bias. With the formalism of the excursion-set mass function, we explicit the tight interconnection between the covariance matrix, bias and halo mass function. We obtain a very accurate (function. We also model the subhalo mass function and its relation to the distinct halo mass function. The set of models obtained provides a complete and precise framework for the description of haloes in the concordance Planck cosmology. Finally, we provide precise analytical fits of the Vmax maximum velocity function up to redshift z publicly available in the Skies and Universes data base.

  14. Accurate line intensities of methane from first-principles calculations

    Science.gov (United States)

    Nikitin, Andrei V.; Rey, Michael; Tyuterev, Vladimir G.

    2017-10-01

    In this work, we report first-principle theoretical predictions of methane spectral line intensities that are competitive with (and complementary to) the best laboratory measurements. A detailed comparison with the most accurate data shows that discrepancies in integrated polyad intensities are in the range of 0.4%-2.3%. This corresponds to estimations of the best available accuracy in laboratory Fourier Transform spectra measurements for this quantity. For relatively isolated strong lines the individual intensity deviations are in the same range. A comparison with the most precise laser measurements of the multiplet intensities in the 2ν3 band gives an agreement within the experimental error margins (about 1%). This is achieved for the first time for five-atomic molecules. In the Supplementary Material we provide the lists of theoretical intensities at 269 K for over 5000 strongest transitions in the range below 6166 cm-1. The advantage of the described method is that this offers a possibility to generate fully assigned exhaustive line lists at various temperature conditions. Extensive calculations up to 12,000 cm-1 including high-T predictions will be made freely available through the TheoReTS information system (http://theorets.univ-reims.fr, http://theorets.tsu.ru) that contains ab initio born line lists and provides a user-friendly graphical interface for a fast simulation of the absorption cross-sections and radiance.

  15. QUESP and QUEST revisited - fast and accurate quantitative CEST experiments.

    Science.gov (United States)

    Zaiss, Moritz; Angelovski, Goran; Demetriou, Eleni; McMahon, Michael T; Golay, Xavier; Scheffler, Klaus

    2018-03-01

    Chemical exchange saturation transfer (CEST) NMR or MRI experiments allow detection of low concentrated molecules with enhanced sensitivity via their proton exchange with the abundant water pool. Be it endogenous metabolites or exogenous contrast agents, an exact quantification of the actual exchange rate is required to design optimal pulse sequences and/or specific sensitive agents. Refined analytical expressions allow deeper insight and improvement of accuracy for common quantification techniques. The accuracy of standard quantification methodologies, such as quantification of exchange rate using varying saturation power or varying saturation time, is improved especially for the case of nonequilibrium initial conditions and weak labeling conditions, meaning the saturation amplitude is smaller than the exchange rate (γB 1  exchange rate using varying saturation power/time' (QUESP/QUEST) equations allow for more accurate exchange rate determination, and provide clear insights on the general principles to execute the experiments and to perform numerical evaluation. The proposed methodology was evaluated on the large-shift regime of paramagnetic chemical-exchange-saturation-transfer agents using simulated data and data of the paramagnetic Eu(III) complex of DOTA-tetraglycineamide. The refined formulas yield improved exchange rate estimation. General convergence intervals of the methods that would apply for smaller shift agents are also discussed. Magn Reson Med 79:1708-1721, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  16. Accurate Holdup Calculations with Predictive Modeling & Data Integration

    Energy Technology Data Exchange (ETDEWEB)

    Azmy, Yousry [North Carolina State Univ., Raleigh, NC (United States). Dept. of Nuclear Engineering; Cacuci, Dan [Univ. of South Carolina, Columbia, SC (United States). Dept. of Mechanical Engineering

    2017-04-03

    In facilities that process special nuclear material (SNM) it is important to account accurately for the fissile material that enters and leaves the plant. Although there are many stages and processes through which materials must be traced and measured, the focus of this project is material that is “held-up” in equipment, pipes, and ducts during normal operation and that can accumulate over time into significant quantities. Accurately estimating the holdup is essential for proper SNM accounting (vis-à-vis nuclear non-proliferation), criticality and radiation safety, waste management, and efficient plant operation. Usually it is not possible to directly measure the holdup quantity and location, so these must be inferred from measured radiation fields, primarily gamma and less frequently neutrons. Current methods to quantify holdup, i.e. Generalized Geometry Holdup (GGH), primarily rely on simple source configurations and crude radiation transport models aided by ad hoc correction factors. This project seeks an alternate method of performing measurement-based holdup calculations using a predictive model that employs state-of-the-art radiation transport codes capable of accurately simulating such situations. Inverse and data assimilation methods use the forward transport model to search for a source configuration that best matches the measured data and simultaneously provide an estimate of the level of confidence in the correctness of such configuration. In this work the holdup problem is re-interpreted as an inverse problem that is under-determined, hence may permit multiple solutions. A probabilistic approach is applied to solving the resulting inverse problem. This approach rates possible solutions according to their plausibility given the measurements and initial information. This is accomplished through the use of Bayes’ Theorem that resolves the issue of multiple solutions by giving an estimate of the probability of observing each possible solution. To use

  17. FTA real-time transit information assessment : white paper on literature review of real-time transit information systems.

    Science.gov (United States)

    Real-time transit information systems are key technology applications within the transit industry designed to provide better customer service by disseminating timely and accurate information. Riders use this information to make various decisions abou...

  18. A Simple and Accurate Method for Measuring Enzyme Activity.

    Science.gov (United States)

    Yip, Din-Yan

    1997-01-01

    Presents methods commonly used for investigating enzyme activity using catalase and presents a new method for measuring catalase activity that is more reliable and accurate. Provides results that are readily reproduced and quantified. Can also be used for investigations of enzyme properties such as the effects of temperature, pH, inhibitors,…

  19. Novel multi-beam radiometers for accurate ocean surveillance

    DEFF Research Database (Denmark)

    Cappellin, C.; Pontoppidan, K.; Nielsen, P. H.

    2014-01-01

    Novel antenna architectures for real aperture multi-beam radiometers providing high resolution and high sensitivity for accurate sea surface temperature (SST) and ocean vector wind (OVW) measurements are investigated. On the basis of the radiometer requirements set for future SST/OVW missions...

  20. Fast and Accurate Residential Fire Detection Using Wireless Sensor Networks

    NARCIS (Netherlands)

    Bahrepour, Majid; Meratnia, Nirvana; Havinga, Paul J.M.

    2010-01-01

    Prompt and accurate residential fire detection is important for on-time fire extinguishing and consequently reducing damages and life losses. To detect fire sensors are needed to measure the environmental parameters and algorithms are required to decide about occurrence of fire. Recently, wireless

  1. Quantifying Accurate Calorie Estimation Using the "Think Aloud" Method

    Science.gov (United States)

    Holmstrup, Michael E.; Stearns-Bruening, Kay; Rozelle, Jeffrey

    2013-01-01

    Objective: Clients often have limited time in a nutrition education setting. An improved understanding of the strategies used to accurately estimate calories may help to identify areas of focused instruction to improve nutrition knowledge. Methods: A "Think Aloud" exercise was recorded during the estimation of calories in a standard dinner meal…

  2. New techniques in television to provide research in three-dimensional real-time or near real-time imagery and reduced cost systems for teleconferencing and educational uses, part 1

    Science.gov (United States)

    Pao, Y. H.; Claspy, P.; Allen, J. E.; Merat, F.

    1979-01-01

    The results are presented of a continuing research and development program the objective of which is to develop a reduced bandwidth television system and a technique for television transmission of holograms. The result of the former is a variable frame rate television system, the operation of which was demonstrated for both black-and-white and color signals. This system employs a novel combination of the inexpensive mass storage capacity of a magnetic disc with the reliability of a digital system for time expansion and compression. Also reported are the results of a theoretical analysis and preliminary feasibility experiment of an innovative system for television transmission of holograms using relatively conventional TV equipment along with a phase modulated reference wave for production of the original interference pattern.

  3. Accurate deuterium spectroscopy for fundamental studies

    Science.gov (United States)

    Wcisło, P.; Thibault, F.; Zaborowski, M.; Wójtewicz, S.; Cygan, A.; Kowzan, G.; Masłowski, P.; Komasa, J.; Puchalski, M.; Pachucki, K.; Ciuryło, R.; Lisak, D.

    2018-07-01

    We present an accurate measurement of the weak quadrupole S(2) 2-0 line in self-perturbed D2 and theoretical ab initio calculations of both collisional line-shape effects and energy of this rovibrational transition. The spectra were collected at the 247-984 Torr pressure range with a frequency-stabilized cavity ring-down spectrometer linked to an optical frequency comb (OFC) referenced to a primary time standard. Our line-shape modeling employed quantum calculations of molecular scattering (the pressure broadening and shift and their speed dependencies were calculated, while the complex frequency of optical velocity-changing collisions was fitted to experimental spectra). The velocity-changing collisions are handled with the hard-sphere collisional kernel. The experimental and theoretical pressure broadening and shift are consistent within 5% and 27%, respectively (the discrepancy for shift is 8% when referred not to the speed averaged value, which is close to zero, but to the range of variability of the speed-dependent shift). We use our high pressure measurement to determine the energy, ν0, of the S(2) 2-0 transition. The ab initio line-shape calculations allowed us to mitigate the expected collisional systematics reaching the 410 kHz accuracy of ν0. We report theoretical determination of ν0 taking into account relativistic and QED corrections up to α5. Our estimation of the accuracy of the theoretical ν0 is 1.3 MHz. We observe 3.4σ discrepancy between experimental and theoretical ν0.

  4. Fast, Accurate Memory Architecture Simulation Technique Using Memory Access Characteristics

    OpenAIRE

    小野, 貴継; 井上, 弘士; 村上, 和彰

    2007-01-01

    This paper proposes a fast and accurate memory architecture simulation technique. To design memory architecture, the first steps commonly involve using trace-driven simulation. However, expanding the design space makes the evaluation time increase. A fast simulation is achieved by a trace size reduction, but it reduces the simulation accuracy. Our approach can reduce the simulation time while maintaining the accuracy of the simulation results. In order to evaluate validity of proposed techniq...

  5. Fast and accurate computation of projected two-point functions

    Science.gov (United States)

    Grasshorn Gebhardt, Henry S.; Jeong, Donghui

    2018-01-01

    We present the two-point function from the fast and accurate spherical Bessel transformation (2-FAST) algorithm1Our code is available at https://github.com/hsgg/twoFAST. for a fast and accurate computation of integrals involving one or two spherical Bessel functions. These types of integrals occur when projecting the galaxy power spectrum P (k ) onto the configuration space, ξℓν(r ), or spherical harmonic space, Cℓ(χ ,χ'). First, we employ the FFTLog transformation of the power spectrum to divide the calculation into P (k )-dependent coefficients and P (k )-independent integrations of basis functions multiplied by spherical Bessel functions. We find analytical expressions for the latter integrals in terms of special functions, for which recursion provides a fast and accurate evaluation. The algorithm, therefore, circumvents direct integration of highly oscillating spherical Bessel functions.

  6. The place of highly accurate methods by RNAA in metrology

    International Nuclear Information System (INIS)

    Dybczynski, R.; Danko, B.; Polkowska-Motrenko, H.; Samczynski, Z.

    2006-01-01

    With the introduction of physical metrological concepts to chemical analysis which require that the result should be accompanied by uncertainty statement written down in terms of Sl units, several researchers started to consider lD-MS as the only method fulfilling this requirement. However, recent publications revealed that in certain cases also some expert laboratories using lD-MS and analyzing the same material, produced results for which their uncertainty statements did not overlap, what theoretically should not have taken place. This shows that no monopoly is good in science and it would be desirable to widen the set of methods acknowledged as primary in inorganic trace analysis. Moreover, lD-MS cannot be used for monoisotopic elements. The need for searching for other methods having similar metrological quality as the lD-MS seems obvious. In this paper, our long-time experience on devising highly accurate ('definitive') methods by RNAA for the determination of selected trace elements in biological materials is reviewed. The general idea of definitive methods based on combination of neutron activation with the highly selective and quantitative isolation of the indicator radionuclide by column chromatography followed by gamma spectrometric measurement is reminded and illustrated by examples of the performance of such methods when determining Cd, Co, Mo, etc. lt is demonstrated that such methods are able to provide very reliable results with very low levels of uncertainty traceable to Sl units

  7. Accurate Recovery of H i Velocity Dispersion from Radio Interferometers

    Energy Technology Data Exchange (ETDEWEB)

    Ianjamasimanana, R. [Max-Planck Institut für Astronomie, Königstuhl 17, D-69117, Heidelberg (Germany); Blok, W. J. G. de [Netherlands Institute for Radio Astronomy (ASTRON), Postbus 2, 7990 AA Dwingeloo (Netherlands); Heald, George H., E-mail: roger@mpia.de, E-mail: blok@astron.nl, E-mail: George.Heald@csiro.au [Kapteyn Astronomical Institute, University of Groningen, P.O. Box 800, 9700 AV, Groningen (Netherlands)

    2017-05-01

    Gas velocity dispersion measures the amount of disordered motion of a rotating disk. Accurate estimates of this parameter are of the utmost importance because the parameter is directly linked to disk stability and star formation. A global measure of the gas velocity dispersion can be inferred from the width of the atomic hydrogen (H i) 21 cm line. We explore how several systematic effects involved in the production of H i cubes affect the estimate of H i velocity dispersion. We do so by comparing the H i velocity dispersion derived from different types of data cubes provided by The H i Nearby Galaxy Survey. We find that residual-scaled cubes best recover the H i velocity dispersion, independent of the weighting scheme used and for a large range of signal-to-noise ratio. For H i observations, where the dirty beam is substantially different from a Gaussian, the velocity dispersion values are overestimated unless the cubes are cleaned close to (e.g., ∼1.5 times) the noise level.

  8. Concurrent and Accurate Short Read Mapping on Multicore Processors.

    Science.gov (United States)

    Martínez, Héctor; Tárraga, Joaquín; Medina, Ignacio; Barrachina, Sergio; Castillo, Maribel; Dopazo, Joaquín; Quintana-Ortí, Enrique S

    2015-01-01

    We introduce a parallel aligner with a work-flow organization for fast and accurate mapping of RNA sequences on servers equipped with multicore processors. Our software, HPG Aligner SA (HPG Aligner SA is an open-source application. The software is available at http://www.opencb.org, exploits a suffix array to rapidly map a large fraction of the RNA fragments (reads), as well as leverages the accuracy of the Smith-Waterman algorithm to deal with conflictive reads. The aligner is enhanced with a careful strategy to detect splice junctions based on an adaptive division of RNA reads into small segments (or seeds), which are then mapped onto a number of candidate alignment locations, providing crucial information for the successful alignment of the complete reads. The experimental results on a platform with Intel multicore technology report the parallel performance of HPG Aligner SA, on RNA reads of 100-400 nucleotides, which excels in execution time/sensitivity to state-of-the-art aligners such as TopHat 2+Bowtie 2, MapSplice, and STAR.

  9. Toward accurate and fast iris segmentation for iris biometrics.

    Science.gov (United States)

    He, Zhaofeng; Tan, Tieniu; Sun, Zhenan; Qiu, Xianchao

    2009-09-01

    Iris segmentation is an essential module in iris recognition because it defines the effective image region used for subsequent processing such as feature extraction. Traditional iris segmentation methods often involve an exhaustive search of a large parameter space, which is time consuming and sensitive to noise. To address these problems, this paper presents a novel algorithm for accurate and fast iris segmentation. After efficient reflection removal, an Adaboost-cascade iris detector is first built to extract a rough position of the iris center. Edge points of iris boundaries are then detected, and an elastic model named pulling and pushing is established. Under this model, the center and radius of the circular iris boundaries are iteratively refined in a way driven by the restoring forces of Hooke's law. Furthermore, a smoothing spline-based edge fitting scheme is presented to deal with noncircular iris boundaries. After that, eyelids are localized via edge detection followed by curve fitting. The novelty here is the adoption of a rank filter for noise elimination and a histogram filter for tackling the shape irregularity of eyelids. Finally, eyelashes and shadows are detected via a learned prediction model. This model provides an adaptive threshold for eyelash and shadow detection by analyzing the intensity distributions of different iris regions. Experimental results on three challenging iris image databases demonstrate that the proposed algorithm outperforms state-of-the-art methods in both accuracy and speed.

  10. An efficient and accurate method to obtain the energy-dependent Green function for general potentials

    International Nuclear Information System (INIS)

    Kramer, T; Heller, E J; Parrott, R E

    2008-01-01

    Time-dependent quantum mechanics provides an intuitive picture of particle propagation in external fields. Semiclassical methods link the classical trajectories of particles with their quantum mechanical propagation. Many analytical results and a variety of numerical methods have been developed to solve the time-dependent Schroedinger equation. The time-dependent methods work for nearly arbitrarily shaped potentials, including sources and sinks via complex-valued potentials. Many quantities are measured at fixed energy, which is seemingly not well suited for a time-dependent formulation. Very few methods exist to obtain the energy-dependent Green function for complicated potentials without resorting to ensemble averages or using certain lead-in arrangements. Here, we demonstrate in detail a time-dependent approach, which can accurately and effectively construct the energy-dependent Green function for very general potentials. The applications of the method are numerous, including chemical, mesoscopic, and atomic physics

  11. Fast and accurate three-dimensional point spread function computation for fluorescence microscopy.

    Science.gov (United States)

    Li, Jizhou; Xue, Feng; Blu, Thierry

    2017-06-01

    The point spread function (PSF) plays a fundamental role in fluorescence microscopy. A realistic and accurately calculated PSF model can significantly improve the performance in 3D deconvolution microscopy and also the localization accuracy in single-molecule microscopy. In this work, we propose a fast and accurate approximation of the Gibson-Lanni model, which has been shown to represent the PSF suitably under a variety of imaging conditions. We express the Kirchhoff's integral in this model as a linear combination of rescaled Bessel functions, thus providing an integral-free way for the calculation. The explicit approximation error in terms of parameters is given numerically. Experiments demonstrate that the proposed approach results in a significantly smaller computational time compared with current state-of-the-art techniques to achieve the same accuracy. This approach can also be extended to other microscopy PSF models.

  12. Accurate computations of monthly average daily extraterrestrial irradiation and the maximum possible sunshine duration

    International Nuclear Information System (INIS)

    Jain, P.C.

    1985-12-01

    The monthly average daily values of the extraterrestrial irradiation on a horizontal plane and the maximum possible sunshine duration are two important parameters that are frequently needed in various solar energy applications. These are generally calculated by solar scientists and engineers each time they are needed and often by using the approximate short-cut methods. Using the accurate analytical expressions developed by Spencer for the declination and the eccentricity correction factor, computations for these parameters have been made for all the latitude values from 90 deg. N to 90 deg. S at intervals of 1 deg. and are presented in a convenient tabular form. Monthly average daily values of the maximum possible sunshine duration as recorded on a Campbell Stoke's sunshine recorder are also computed and presented. These tables would avoid the need for repetitive and approximate calculations and serve as a useful ready reference for providing accurate values to the solar energy scientists and engineers

  13. More accurate picture of human body organs

    International Nuclear Information System (INIS)

    Kolar, J.

    1985-01-01

    Computerized tomography and nucler magnetic resonance tomography (NMRT) are revolutionary contributions to radiodiagnosis because they allow to obtain a more accurate image of human body organs. The principles are described of both methods. Attention is mainly devoted to NMRT which has clinically only been used for three years. It does not burden the organism with ionizing radiation. (Ha)

  14. Fast and accurate methods for phylogenomic analyses

    Directory of Open Access Journals (Sweden)

    Warnow Tandy

    2011-10-01

    Full Text Available Abstract Background Species phylogenies are not estimated directly, but rather through phylogenetic analyses of different gene datasets. However, true gene trees can differ from the true species tree (and hence from one another due to biological processes such as horizontal gene transfer, incomplete lineage sorting, and gene duplication and loss, so that no single gene tree is a reliable estimate of the species tree. Several methods have been developed to estimate species trees from estimated gene trees, differing according to the specific algorithmic technique used and the biological model used to explain differences between species and gene trees. Relatively little is known about the relative performance of these methods. Results We report on a study evaluating several different methods for estimating species trees from sequence datasets, simulating sequence evolution under a complex model including indels (insertions and deletions, substitutions, and incomplete lineage sorting. The most important finding of our study is that some fast and simple methods are nearly as accurate as the most accurate methods, which employ sophisticated statistical methods and are computationally quite intensive. We also observe that methods that explicitly consider errors in the estimated gene trees produce more accurate trees than methods that assume the estimated gene trees are correct. Conclusions Our study shows that highly accurate estimations of species trees are achievable, even when gene trees differ from each other and from the species tree, and that these estimations can be obtained using fairly simple and computationally tractable methods.

  15. Accurate overlaying for mobile augmented reality

    NARCIS (Netherlands)

    Pasman, W; van der Schaaf, A; Lagendijk, RL; Jansen, F.W.

    1999-01-01

    Mobile augmented reality requires accurate alignment of virtual information with objects visible in the real world. We describe a system for mobile communications to be developed to meet these strict alignment criteria using a combination of computer vision. inertial tracking and low-latency

  16. Accurate activity recognition in a home setting

    NARCIS (Netherlands)

    van Kasteren, T.; Noulas, A.; Englebienne, G.; Kröse, B.

    2008-01-01

    A sensor system capable of automatically recognizing activities would allow many potential ubiquitous applications. In this paper, we present an easy to install sensor network and an accurate but inexpensive annotation method. A recorded dataset consisting of 28 days of sensor data and its

  17. Highly accurate surface maps from profilometer measurements

    Science.gov (United States)

    Medicus, Kate M.; Nelson, Jessica D.; Mandina, Mike P.

    2013-04-01

    Many aspheres and free-form optical surfaces are measured using a single line trace profilometer which is limiting because accurate 3D corrections are not possible with the single trace. We show a method to produce an accurate fully 2.5D surface height map when measuring a surface with a profilometer using only 6 traces and without expensive hardware. The 6 traces are taken at varying angular positions of the lens, rotating the part between each trace. The output height map contains low form error only, the first 36 Zernikes. The accuracy of the height map is ±10% of the actual Zernike values and within ±3% of the actual peak to valley number. The calculated Zernike values are affected by errors in the angular positioning, by the centering of the lens, and to a small effect, choices made in the processing algorithm. We have found that the angular positioning of the part should be better than 1?, which is achievable with typical hardware. The centering of the lens is essential to achieving accurate measurements. The part must be centered to within 0.5% of the diameter to achieve accurate results. This value is achievable with care, with an indicator, but the part must be edged to a clean diameter.

  18. Simple Mathematical Models Do Not Accurately Predict Early SIV Dynamics

    Directory of Open Access Journals (Sweden)

    Cecilia Noecker

    2015-03-01

    Full Text Available Upon infection of a new host, human immunodeficiency virus (HIV replicates in the mucosal tissues and is generally undetectable in circulation for 1–2 weeks post-infection. Several interventions against HIV including vaccines and antiretroviral prophylaxis target virus replication at this earliest stage of infection. Mathematical models have been used to understand how HIV spreads from mucosal tissues systemically and what impact vaccination and/or antiretroviral prophylaxis has on viral eradication. Because predictions of such models have been rarely compared to experimental data, it remains unclear which processes included in these models are critical for predicting early HIV dynamics. Here we modified the “standard” mathematical model of HIV infection to include two populations of infected cells: cells that are actively producing the virus and cells that are transitioning into virus production mode. We evaluated the effects of several poorly known parameters on infection outcomes in this model and compared model predictions to experimental data on infection of non-human primates with variable doses of simian immunodifficiency virus (SIV. First, we found that the mode of virus production by infected cells (budding vs. bursting has a minimal impact on the early virus dynamics for a wide range of model parameters, as long as the parameters are constrained to provide the observed rate of SIV load increase in the blood of infected animals. Interestingly and in contrast with previous results, we found that the bursting mode of virus production generally results in a higher probability of viral extinction than the budding mode of virus production. Second, this mathematical model was not able to accurately describe the change in experimentally determined probability of host infection with increasing viral doses. Third and finally, the model was also unable to accurately explain the decline in the time to virus detection with increasing viral

  19. Accurate guitar tuning by cochlear implant musicians.

    Directory of Open Access Journals (Sweden)

    Thomas Lu

    Full Text Available Modern cochlear implant (CI users understand speech but find difficulty in music appreciation due to poor pitch perception. Still, some deaf musicians continue to perform with their CI. Here we show unexpected results that CI musicians can reliably tune a guitar by CI alone and, under controlled conditions, match simultaneously presented tones to <0.5 Hz. One subject had normal contralateral hearing and produced more accurate tuning with CI than his normal ear. To understand these counterintuitive findings, we presented tones sequentially and found that tuning error was larger at ∼ 30 Hz for both subjects. A third subject, a non-musician CI user with normal contralateral hearing, showed similar trends in performance between CI and normal hearing ears but with less precision. This difference, along with electric analysis, showed that accurate tuning was achieved by listening to beats rather than discriminating pitch, effectively turning a spectral task into a temporal discrimination task.

  20. On accurate determination of contact angle

    Science.gov (United States)

    Concus, P.; Finn, R.

    1992-01-01

    Methods are proposed that exploit a microgravity environment to obtain highly accurate measurement of contact angle. These methods, which are based on our earlier mathematical results, do not require detailed measurement of a liquid free-surface, as they incorporate discontinuous or nearly-discontinuous behavior of the liquid bulk in certain container geometries. Physical testing is planned in the forthcoming IML-2 space flight and in related preparatory ground-based experiments.

  1. Software Estimation: Developing an Accurate, Reliable Method

    Science.gov (United States)

    2011-08-01

    based and size-based estimates is able to accurately plan, launch, and execute on schedule. Bob Sinclair, NAWCWD Chris Rickets , NAWCWD Brad Hodgins...Office by Carnegie Mellon University. SMPSP and SMTSP are service marks of Carnegie Mellon University. 1. Rickets , Chris A, “A TSP Software Maintenance...Life Cycle”, CrossTalk, March, 2005. 2. Koch, Alan S, “TSP Can Be the Building blocks for CMMI”, CrossTalk, March, 2005. 3. Hodgins, Brad, Rickets

  2. Accurate multiplicity scaling in isotopically conjugate reactions

    International Nuclear Information System (INIS)

    Golokhvastov, A.I.

    1989-01-01

    The generation of accurate scaling of mutiplicity distributions is presented. The distributions of π - mesons (negative particles) and π + mesons in different nucleon-nucleon interactions (PP, NP and NN) are described by the same universal function Ψ(z) and the same energy dependence of the scale parameter which determines the stretching factor for the unit function Ψ(z) to obtain the desired multiplicity distribution. 29 refs.; 6 figs

  3. Virtual Reality Based Accurate Radioactive Source Representation and Dosimetry for Training Applications

    International Nuclear Information System (INIS)

    Molto-Caracena, T.; Vendrell Vidal, E.; Goncalves, J.G.M.; Peerani, P.; )

    2015-01-01

    Virtual Reality (VR) technologies have much potential for training applications. Success relies on the capacity to provide a real-time immersive effect to a trainee. For a training application to be an effective/meaningful tool, 3D realistic scenarios are not enough. Indeed, it is paramount having sufficiently accurate models of the behaviour of the instruments to be used by a trainee. This will enable the required level of user's interactivity. Specifically, when dealing with simulation of radioactive sources, a VR model based application must compute the dose rate with equivalent accuracy and in about the same time as a real instrument. A conflicting requirement is the need to provide a smooth visual rendering enabling spatial interactivity and interaction. This paper presents a VR based prototype which accurately computes the dose rate of radioactive and nuclear sources that can be selected from a wide library. Dose measurements reflect local conditions, i.e., presence of (a) shielding materials with any shape and type and (b) sources with any shape and dimension. Due to a novel way of representing radiation sources, the system is fast enough to grant the necessary user interactivity. The paper discusses the application of this new method and its advantages in terms of time setting, cost and logistics. (author)

  4. Mental models accurately predict emotion transitions.

    Science.gov (United States)

    Thornton, Mark A; Tamir, Diana I

    2017-06-06

    Successful social interactions depend on people's ability to predict others' future actions and emotions. People possess many mechanisms for perceiving others' current emotional states, but how might they use this information to predict others' future states? We hypothesized that people might capitalize on an overlooked aspect of affective experience: current emotions predict future emotions. By attending to regularities in emotion transitions, perceivers might develop accurate mental models of others' emotional dynamics. People could then use these mental models of emotion transitions to predict others' future emotions from currently observable emotions. To test this hypothesis, studies 1-3 used data from three extant experience-sampling datasets to establish the actual rates of emotional transitions. We then collected three parallel datasets in which participants rated the transition likelihoods between the same set of emotions. Participants' ratings of emotion transitions predicted others' experienced transitional likelihoods with high accuracy. Study 4 demonstrated that four conceptual dimensions of mental state representation-valence, social impact, rationality, and human mind-inform participants' mental models. Study 5 used 2 million emotion reports on the Experience Project to replicate both of these findings: again people reported accurate models of emotion transitions, and these models were informed by the same four conceptual dimensions. Importantly, neither these conceptual dimensions nor holistic similarity could fully explain participants' accuracy, suggesting that their mental models contain accurate information about emotion dynamics above and beyond what might be predicted by static emotion knowledge alone.

  5. Mental models accurately predict emotion transitions

    Science.gov (United States)

    Thornton, Mark A.; Tamir, Diana I.

    2017-01-01

    Successful social interactions depend on people’s ability to predict others’ future actions and emotions. People possess many mechanisms for perceiving others’ current emotional states, but how might they use this information to predict others’ future states? We hypothesized that people might capitalize on an overlooked aspect of affective experience: current emotions predict future emotions. By attending to regularities in emotion transitions, perceivers might develop accurate mental models of others’ emotional dynamics. People could then use these mental models of emotion transitions to predict others’ future emotions from currently observable emotions. To test this hypothesis, studies 1–3 used data from three extant experience-sampling datasets to establish the actual rates of emotional transitions. We then collected three parallel datasets in which participants rated the transition likelihoods between the same set of emotions. Participants’ ratings of emotion transitions predicted others’ experienced transitional likelihoods with high accuracy. Study 4 demonstrated that four conceptual dimensions of mental state representation—valence, social impact, rationality, and human mind—inform participants’ mental models. Study 5 used 2 million emotion reports on the Experience Project to replicate both of these findings: again people reported accurate models of emotion transitions, and these models were informed by the same four conceptual dimensions. Importantly, neither these conceptual dimensions nor holistic similarity could fully explain participants’ accuracy, suggesting that their mental models contain accurate information about emotion dynamics above and beyond what might be predicted by static emotion knowledge alone. PMID:28533373

  6. Automated Development of Accurate Algorithms and Efficient Codes for Computational Aeroacoustics

    Science.gov (United States)

    Goodrich, John W.; Dyson, Rodger W.

    1999-01-01

    The simulation of sound generation and propagation in three space dimensions with realistic aircraft components is a very large time dependent computation with fine details. Simulations in open domains with embedded objects require accurate and robust algorithms for propagation, for artificial inflow and outflow boundaries, and for the definition of geometrically complex objects. The development, implementation, and validation of methods for solving these demanding problems is being done to support the NASA pillar goals for reducing aircraft noise levels. Our goal is to provide algorithms which are sufficiently accurate and efficient to produce usable results rapidly enough to allow design engineers to study the effects on sound levels of design changes in propulsion systems, and in the integration of propulsion systems with airframes. There is a lack of design tools for these purposes at this time. Our technical approach to this problem combines the development of new, algorithms with the use of Mathematica and Unix utilities to automate the algorithm development, code implementation, and validation. We use explicit methods to ensure effective implementation by domain decomposition for SPMD parallel computing. There are several orders of magnitude difference in the computational efficiencies of the algorithms which we have considered. We currently have new artificial inflow and outflow boundary conditions that are stable, accurate, and unobtrusive, with implementations that match the accuracy and efficiency of the propagation methods. The artificial numerical boundary treatments have been proven to have solutions which converge to the full open domain problems, so that the error from the boundary treatments can be driven as low as is required. The purpose of this paper is to briefly present a method for developing highly accurate algorithms for computational aeroacoustics, the use of computer automation in this process, and a brief survey of the algorithms that

  7. The description of a method for accurately estimating creatinine clearance in acute kidney injury.

    Science.gov (United States)

    Mellas, John

    2016-05-01

    Acute kidney injury (AKI) is a common and serious condition encountered in hospitalized patients. The severity of kidney injury is defined by the RIFLE, AKIN, and KDIGO criteria which attempt to establish the degree of renal impairment. The KDIGO guidelines state that the creatinine clearance should be measured whenever possible in AKI and that the serum creatinine concentration and creatinine clearance remain the best clinical indicators of renal function. Neither the RIFLE, AKIN, nor KDIGO criteria estimate actual creatinine clearance. Furthermore there are no accepted methods for accurately estimating creatinine clearance (K) in AKI. The present study describes a unique method for estimating K in AKI using urine creatinine excretion over an established time interval (E), an estimate of creatinine production over the same time interval (P), and the estimated static glomerular filtration rate (sGFR), at time zero, utilizing the CKD-EPI formula. Using these variables estimated creatinine clearance (Ke)=E/P * sGFR. The method was tested for validity using simulated patients where actual creatinine clearance (Ka) was compared to Ke in several patients, both male and female, and of various ages, body weights, and degrees of renal impairment. These measurements were made at several serum creatinine concentrations in an attempt to determine the accuracy of this method in the non-steady state. In addition E/P and Ke was calculated in hospitalized patients, with AKI, and seen in nephrology consultation by the author. In these patients the accuracy of the method was determined by looking at the following metrics; E/P>1, E/P1 and 0.907 (0.841, 0.973) for 0.95 ml/min accurately predicted the ability to terminate renal replacement therapy in AKI. Include the need to measure urine volume accurately. Furthermore the precision of the method requires accurate estimates of sGFR, while a reasonable measure of P is crucial to estimating Ke. The present study provides the

  8. An accurate determination of the flux within a slab

    International Nuclear Information System (INIS)

    Ganapol, B.D.; Lapenta, G.

    1993-01-01

    During the past decade, several articles have been written concerning accurate solutions to the monoenergetic neutron transport equation in infinite and semi-infinite geometries. The numerical formulations found in these articles were based primarily on the extensive theoretical investigations performed by the open-quotes transport greatsclose quotes such as Chandrasekhar, Busbridge, Sobolev, and Ivanov, to name a few. The development of numerical solutions in infinite and semi-infinite geometries represents an example of how mathematical transport theory can be utilized to provide highly accurate and efficient numerical transport solutions. These solutions, or analytical benchmarks, are useful as open-quotes industry standards,close quotes which provide guidance to code developers and promote learning in the classroom. The high accuracy of these benchmarks is directly attributable to the rapid advancement of the state of computing and computational methods. Transport calculations that were beyond the capability of the open-quotes supercomputersclose quotes of just a few years ago are now possible at one's desk. In this paper, we again build upon the past to tackle the slab problem, which is of the next level of difficulty in comparison to infinite media problems. The formulation is based on the monoenergetic Green's function, which is the most fundamental transport solution. This method of solution requires a fast and accurate evaluation of the Green's function, which, with today's computational power, is now readily available

  9. Discrete sensors distribution for accurate plantar pressure analyses.

    Science.gov (United States)

    Claverie, Laetitia; Ille, Anne; Moretto, Pierre

    2016-12-01

    The aim of this study was to determine the distribution of discrete sensors under the footprint for accurate plantar pressure analyses. For this purpose, two different sensor layouts have been tested and compared, to determine which was the most accurate to monitor plantar pressure with wireless devices in research and/or clinical practice. Ten healthy volunteers participated in the study (age range: 23-58 years). The barycenter of pressures (BoP) determined from the plantar pressure system (W-inshoe®) was compared to the center of pressures (CoP) determined from a force platform (AMTI) in the medial-lateral (ML) and anterior-posterior (AP) directions. Then, the vertical ground reaction force (vGRF) obtained from both W-inshoe® and force platform was compared for both layouts for each subject. The BoP and vGRF determined from the plantar pressure system data showed good correlation (SCC) with those determined from the force platform data, notably for the second sensor organization (ML SCC= 0.95; AP SCC=0.99; vGRF SCC=0.91). The study demonstrates that an adjusted placement of removable sensors is key to accurate plantar pressure analyses. These results are promising for a plantar pressure recording outside clinical or laboratory settings, for long time monitoring, real time feedback or for whatever activity requiring a low-cost system. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  10. Using Coaching to Provide Ongoing Support and Supervision to Out-of-School Time Staff. Part 3 in a Series on Implementing Evidence-Based Practices in Out-of-School Time Programs: The Role of Frontline Staff. Research-to-Results Brief. Publication #2009-06

    Science.gov (United States)

    Burkhauser, Mary; Metz, Allison J. R.

    2009-01-01

    Although skills needed by out-of-school time practitioners can be introduced during training, many skills can only really be learned on the job with ongoing support and supervision provided by a "coach." Research from both the education and out-of-school time fields supports the value of staff coaching as a professional development tool, and staff…

  11. The first accurate description of an aurora

    Science.gov (United States)

    Schröder, Wilfried

    2006-12-01

    As technology has advanced, the scientific study of auroral phenomena has increased by leaps and bounds. A look back at the earliest descriptions of aurorae offers an interesting look into how medieval scholars viewed the subjects that we study.Although there are earlier fragmentary references in the literature, the first accurate description of the aurora borealis appears to be that published by the German Catholic scholar Konrad von Megenberg (1309-1374) in his book Das Buch der Natur (The Book of Nature). The book was written between 1349 and 1350.

  12. Accurate Charge Densities from Powder Diffraction

    DEFF Research Database (Denmark)

    Bindzus, Niels; Wahlberg, Nanna; Becker, Jacob

    Synchrotron powder X-ray diffraction has in recent years advanced to a level, where it has become realistic to probe extremely subtle electronic features. Compared to single-crystal diffraction, it may be superior for simple, high-symmetry crystals owing to negligible extinction effects and minimal...... peak overlap. Additionally, it offers the opportunity for collecting data on a single scale. For charge densities studies, the critical task is to recover accurate and bias-free structure factors from the diffraction pattern. This is the focal point of the present study, scrutinizing the performance...

  13. Arbitrarily accurate twin composite π -pulse sequences

    Science.gov (United States)

    Torosov, Boyan T.; Vitanov, Nikolay V.

    2018-04-01

    We present three classes of symmetric broadband composite pulse sequences. The composite phases are given by analytic formulas (rational fractions of π ) valid for any number of constituent pulses. The transition probability is expressed by simple analytic formulas and the order of pulse area error compensation grows linearly with the number of pulses. Therefore, any desired compensation order can be produced by an appropriate composite sequence; in this sense, they are arbitrarily accurate. These composite pulses perform equally well as or better than previously published ones. Moreover, the current sequences are more flexible as they allow total pulse areas of arbitrary integer multiples of π .

  14. Systematization of Accurate Discrete Optimization Methods

    Directory of Open Access Journals (Sweden)

    V. A. Ovchinnikov

    2015-01-01

    Full Text Available The object of study of this paper is to define accurate methods for solving combinatorial optimization problems of structural synthesis. The aim of the work is to systemize the exact methods of discrete optimization and define their applicability to solve practical problems.The article presents the analysis, generalization and systematization of classical methods and algorithms described in the educational and scientific literature.As a result of research a systematic presentation of combinatorial methods for discrete optimization described in various sources is given, their capabilities are described and properties of the tasks to be solved using the appropriate methods are specified.

  15. Accurate lithography simulation model based on convolutional neural networks

    Science.gov (United States)

    Watanabe, Yuki; Kimura, Taiki; Matsunawa, Tetsuaki; Nojima, Shigeki

    2017-07-01

    Lithography simulation is an essential technique for today's semiconductor manufacturing process. In order to calculate an entire chip in realistic time, compact resist model is commonly used. The model is established for faster calculation. To have accurate compact resist model, it is necessary to fix a complicated non-linear model function. However, it is difficult to decide an appropriate function manually because there are many options. This paper proposes a new compact resist model using CNN (Convolutional Neural Networks) which is one of deep learning techniques. CNN model makes it possible to determine an appropriate model function and achieve accurate simulation. Experimental results show CNN model can reduce CD prediction errors by 70% compared with the conventional model.

  16. Fast and accurate edge orientation processing during object manipulation

    Science.gov (United States)

    Flanagan, J Randall; Johansson, Roland S

    2018-01-01

    Quickly and accurately extracting information about a touched object’s orientation is a critical aspect of dexterous object manipulation. However, the speed and acuity of tactile edge orientation processing with respect to the fingertips as reported in previous perceptual studies appear inadequate in these respects. Here we directly establish the tactile system’s capacity to process edge-orientation information during dexterous manipulation. Participants extracted tactile information about edge orientation very quickly, using it within 200 ms of first touching the object. Participants were also strikingly accurate. With edges spanning the entire fingertip, edge-orientation resolution was better than 3° in our object manipulation task, which is several times better than reported in previous perceptual studies. Performance remained impressive even with edges as short as 2 mm, consistent with our ability to precisely manipulate very small objects. Taken together, our results radically redefine the spatial processing capacity of the tactile system. PMID:29611804

  17. Serial fusion of Eulerian and Lagrangian approaches for accurate heart-rate estimation using face videos.

    Science.gov (United States)

    Gupta, Puneet; Bhowmick, Brojeshwar; Pal, Arpan

    2017-07-01

    Camera-equipped devices are ubiquitous and proliferating in the day-to-day life. Accurate heart rate (HR) estimation from the face videos acquired from the low cost cameras in a non-contact manner, can be used in many real-world scenarios and hence, require rigorous exploration. This paper has presented an accurate and near real-time HR estimation system using these face videos. It is based on the phenomenon that the color and motion variations in the face video are closely related to the heart beat. The variations also contain the noise due to facial expressions, respiration, eye blinking and environmental factors which are handled by the proposed system. Neither Eulerian nor Lagrangian temporal signals can provide accurate HR in all the cases. The cases where Eulerian temporal signals perform spuriously are determined using a novel poorness measure and then both the Eulerian and Lagrangian temporal signals are employed for better HR estimation. Such a fusion is referred as serial fusion. Experimental results reveal that the error introduced in the proposed algorithm is 1.8±3.6 which is significantly lower than the existing well known systems.

  18. A multiple regression analysis for accurate background subtraction in 99Tcm-DTPA renography

    International Nuclear Information System (INIS)

    Middleton, G.W.; Thomson, W.H.; Davies, I.H.; Morgan, A.

    1989-01-01

    A technique for accurate background subtraction in 99 Tc m -DTPA renography is described. The technique is based on a multiple regression analysis of the renal curves and separate heart and soft tissue curves which together represent background activity. It is compared, in over 100 renograms, with a previously described linear regression technique. Results show that the method provides accurate background subtraction, even in very poorly functioning kidneys, thus enabling relative renal filtration and excretion to be accurately estimated. (author)

  19. DNA barcode data accurately assign higher spider taxa

    Directory of Open Access Journals (Sweden)

    Jonathan A. Coddington

    2016-07-01

    , the quality of the underlying database impacts accuracy of results; many outliers in our dataset could be attributed to taxonomic and/or sequencing errors in BOLD and GenBank. It seems that an accurate and complete reference library of families and genera of life could provide accurate higher level taxonomic identifications cheaply and accessibly, within years rather than decades.

  20. Accurate Energy Consumption Modeling of IEEE 802.15.4e TSCH Using Dual-BandOpenMote Hardware.

    Science.gov (United States)

    Daneels, Glenn; Municio, Esteban; Van de Velde, Bruno; Ergeerts, Glenn; Weyn, Maarten; Latré, Steven; Famaey, Jeroen

    2018-02-02

    The Time-Slotted Channel Hopping (TSCH) mode of the IEEE 802.15.4e amendment aims to improve reliability and energy efficiency in industrial and other challenging Internet-of-Things (IoT) environments. This paper presents an accurate and up-to-date energy consumption model for devices using this IEEE 802.15.4e TSCH mode. The model identifies all network-related CPU and radio state changes, thus providing a precise representation of the device behavior and an accurate prediction of its energy consumption. Moreover, energy measurements were performed with a dual-band OpenMote device, running the OpenWSN firmware. This allows the model to be used for devices using 2.4 GHz, as well as 868 MHz. Using these measurements, several network simulations were conducted to observe the TSCH energy consumption effects in end-to-end communication for both frequency bands. Experimental verification of the model shows that it accurately models the consumption for all possible packet sizes and that the calculated consumption on average differs less than 3% from the measured consumption. This deviation includes measurement inaccuracies and the variations of the guard time. As such, the proposed model is very suitable for accurate energy consumption modeling of TSCH networks.

  1. Onboard Autonomous Corrections for Accurate IRF Pointing.

    Science.gov (United States)

    Jorgensen, J. L.; Betto, M.; Denver, T.

    2002-05-01

    Over the past decade, the Noise Equivalent Angle (NEA) of onboard attitude reference instruments, has decreased from tens-of-arcseconds to the sub-arcsecond level. This improved performance is partly due to improved sensor-technology with enhanced signal to noise ratios, partly due to improved processing electronics which allows for more sophisticated and faster signal processing. However, the main reason for the increased precision, is the application of onboard autonomy, which apart from simple outlier rejection also allows for removal of "false positive" answers, and other "unexpected" noise sources, that otherwise would degrade the quality of the measurements (e.g. discrimination between signals caused by starlight and ionizing radiation). The utilization of autonomous signal processing has also provided the means for another onboard processing step, namely the autonomous recovery from lost in space, where the attitude instrument without a priori knowledge derive the absolute attitude, i.e. in IRF coordinates, within fractions of a second. Combined with precise orbital state or position data, the absolute attitude information opens for multiple ways to improve the mission performance, either by reducing operations costs, by increasing pointing accuracy, by reducing mission expendables, or by providing backup decision information in case of anomalies. The Advanced Stellar Compass's (ASC) is a miniature, high accuracy, attitude instrument which features fully autonomous operations. The autonomy encompass all direct steps from automatic health checkout at power-on, over fully automatic SEU and SEL handling and proton induced sparkle removal, to recovery from "lost in space", and optical disturbance detection and handling. But apart from these more obvious autonomy functions, the ASC also features functions to handle and remove the aforementioned residuals. These functions encompass diverse operators such as a full orbital state vector model with automatic cloud

  2. Accurate position estimation methods based on electrical impedance tomography measurements

    Science.gov (United States)

    Vergara, Samuel; Sbarbaro, Daniel; Johansen, T. A.

    2017-08-01

    than 0.05% of the tomograph radius value. These results demonstrate that the proposed approaches can estimate an object’s position accurately based on EIT measurements if enough process information is available for training or modelling. Since they do not require complex calculations it is possible to use them in real-time applications without requiring high-performance computers.

  3. Improved management of radiotherapy departments through accurate cost data

    International Nuclear Information System (INIS)

    Kesteloot, K.; Lievens, Y.; Schueren, E. van der

    2000-01-01

    Escalating health care expenses urge Governments towards cost containment. More accurate data on the precise costs of health care interventions are needed. We performed an aggregate cost calculation of radiation therapy departments and treatments and discussed the different cost components. The costs of a radiotherapy department were estimated, based on accreditation norms for radiotherapy departments set forth in the Belgian legislation. The major cost components of radiotherapy are the cost of buildings and facilities, equipment, medical and non-medical staff, materials and overhead. They respectively represent around 3, 30, 50, 4 and 13% of the total costs, irrespective of the department size. The average cost per patient lowers with increasing department size and optimal utilization of resources. Radiotherapy treatment costs vary in a stepwise fashion: minor variations of patient load do not affect the cost picture significantly due to a small impact of variable costs. With larger increases in patient load however, additional equipment and/or staff will become necessary, resulting in additional semi-fixed costs and an important increase in costs. A sensitivity analysis of these two major cost inputs shows that a decrease in total costs of 12-13% can be obtained by assuming a 20% less than full time availability of personnel; that due to evolving seniority levels, the annual increase in wage costs is estimated to be more than 1%; that by changing the clinical life-time of buildings and equipment with unchanged interest rate, a 5% reduction of total costs and cost per patient can be calculated. More sophisticated equipment will not have a very large impact on the cost (±4000 BEF/patient), provided that the additional equipment is adapted to the size of the department. That the recommendations we used, based on the Belgian legislation, are not outrageous is shown by replacing them by the USA Blue book recommendations. Depending on the department size, costs in

  4. New simple method for fast and accurate measurement of volumes

    International Nuclear Information System (INIS)

    Frattolillo, Antonio

    2006-01-01

    A new simple method is presented, which allows us to measure in just a few minutes but with reasonable accuracy (less than 1%) the volume confined inside a generic enclosure, regardless of the complexity of its shape. The technique proposed also allows us to measure the volume of any portion of a complex manifold, including, for instance, pipes and pipe fittings, valves, gauge heads, and so on, without disassembling the manifold at all. To this purpose an airtight variable volume is used, whose volume adjustment can be precisely measured; it has an overall capacity larger than that of the unknown volume. Such a variable volume is initially filled with a suitable test gas (for instance, air) at a known pressure, as carefully measured by means of a high precision capacitive gauge. By opening a valve, the test gas is allowed to expand into the previously evacuated unknown volume. A feedback control loop reacts to the resulting finite pressure drop, thus contracting the variable volume until the pressure exactly retrieves its initial value. The overall reduction of the variable volume achieved at the end of this process gives a direct measurement of the unknown volume, and definitively gets rid of the problem of dead spaces. The method proposed actually does not require the test gas to be rigorously held at a constant temperature, thus resulting in a huge simplification as compared to complex arrangements commonly used in metrology (gas expansion method), which can grant extremely accurate measurement but requires rather expensive equipments and results in time consuming methods, being therefore impractical in most applications. A simple theoretical analysis of the thermodynamic cycle and the results of experimental tests are described, which demonstrate that, in spite of its simplicity, the method provides a measurement accuracy within 0.5%. The system requires just a few minutes to complete a single measurement, and is ready immediately at the end of the process. The

  5. Can blind persons accurately assess body size from the voice?

    Science.gov (United States)

    Pisanski, Katarzyna; Oleszkiewicz, Anna; Sorokowska, Agnieszka

    2016-04-01

    Vocal tract resonances provide reliable information about a speaker's body size that human listeners use for biosocial judgements as well as speech recognition. Although humans can accurately assess men's relative body size from the voice alone, how this ability is acquired remains unknown. In this study, we test the prediction that accurate voice-based size estimation is possible without prior audiovisual experience linking low frequencies to large bodies. Ninety-one healthy congenitally or early blind, late blind and sighted adults (aged 20-65) participated in the study. On the basis of vowel sounds alone, participants assessed the relative body sizes of male pairs of varying heights. Accuracy of voice-based body size assessments significantly exceeded chance and did not differ among participants who were sighted, or congenitally blind or who had lost their sight later in life. Accuracy increased significantly with relative differences in physical height between men, suggesting that both blind and sighted participants used reliable vocal cues to size (i.e. vocal tract resonances). Our findings demonstrate that prior visual experience is not necessary for accurate body size estimation. This capacity, integral to both nonverbal communication and speech perception, may be present at birth or may generalize from broader cross-modal correspondences. © 2016 The Author(s).

  6. Indexed variation graphs for efficient and accurate resistome profiling.

    Science.gov (United States)

    Rowe, Will P M; Winn, Martyn D

    2018-05-14

    Antimicrobial resistance remains a major threat to global health. Profiling the collective antimicrobial resistance genes within a metagenome (the "resistome") facilitates greater understanding of antimicrobial resistance gene diversity and dynamics. In turn, this can allow for gene surveillance, individualised treatment of bacterial infections and more sustainable use of antimicrobials. However, resistome profiling can be complicated by high similarity between reference genes, as well as the sheer volume of sequencing data and the complexity of analysis workflows. We have developed an efficient and accurate method for resistome profiling that addresses these complications and improves upon currently available tools. Our method combines a variation graph representation of gene sets with an LSH Forest indexing scheme to allow for fast classification of metagenomic sequence reads using similarity-search queries. Subsequent hierarchical local alignment of classified reads against graph traversals enables accurate reconstruction of full-length gene sequences using a scoring scheme. We provide our implementation, GROOT, and show it to be both faster and more accurate than a current reference-dependent tool for resistome profiling. GROOT runs on a laptop and can process a typical 2 gigabyte metagenome in 2 minutes using a single CPU. Our method is not restricted to resistome profiling and has the potential to improve current metagenomic workflows. GROOT is written in Go and is available at https://github.com/will-rowe/groot (MIT license). will.rowe@stfc.ac.uk. Supplementary data are available at Bioinformatics online.

  7. Accurate predictions for the LHC made easy

    CERN Multimedia

    CERN. Geneva

    2014-01-01

    The data recorded by the LHC experiments is of a very high quality. To get the most out of the data, precise theory predictions, including uncertainty estimates, are needed to reduce as much as possible theoretical bias in the experimental analyses. Recently, significant progress has been made in computing Next-to-Leading Order (NLO) computations, including matching to the parton shower, that allow for these accurate, hadron-level predictions. I shall discuss one of these efforts, the MadGraph5_aMC@NLO program, that aims at the complete automation of predictions at the NLO accuracy within the SM as well as New Physics theories. I’ll illustrate some of the theoretical ideas behind this program, show some selected applications to LHC physics, as well as describe the future plans.

  8. Apparatus for accurately measuring high temperatures

    Science.gov (United States)

    Smith, D.D.

    The present invention is a thermometer used for measuring furnace temperatures in the range of about 1800/sup 0/ to 2700/sup 0/C. The thermometer comprises a broadband multicolor thermal radiation sensor positioned to be in optical alignment with the end of a blackbody sight tube extending into the furnace. A valve-shutter arrangement is positioned between the radiation sensor and the sight tube and a chamber for containing a charge of high pressure gas is positioned between the valve-shutter arrangement and the radiation sensor. A momentary opening of the valve shutter arrangement allows a pulse of the high gas to purge the sight tube of air-borne thermal radiation contaminants which permits the radiation sensor to accurately measure the thermal radiation emanating from the end of the sight tube.

  9. Accurate Modeling Method for Cu Interconnect

    Science.gov (United States)

    Yamada, Kenta; Kitahara, Hiroshi; Asai, Yoshihiko; Sakamoto, Hideo; Okada, Norio; Yasuda, Makoto; Oda, Noriaki; Sakurai, Michio; Hiroi, Masayuki; Takewaki, Toshiyuki; Ohnishi, Sadayuki; Iguchi, Manabu; Minda, Hiroyasu; Suzuki, Mieko

    This paper proposes an accurate modeling method of the copper interconnect cross-section in which the width and thickness dependence on layout patterns and density caused by processes (CMP, etching, sputtering, lithography, and so on) are fully, incorporated and universally expressed. In addition, we have developed specific test patterns for the model parameters extraction, and an efficient extraction flow. We have extracted the model parameters for 0.15μm CMOS using this method and confirmed that 10%τpd error normally observed with conventional LPE (Layout Parameters Extraction) was completely dissolved. Moreover, it is verified that the model can be applied to more advanced technologies (90nm, 65nm and 55nm CMOS). Since the interconnect delay variations due to the processes constitute a significant part of what have conventionally been treated as random variations, use of the proposed model could enable one to greatly narrow the guardbands required to guarantee a desired yield, thereby facilitating design closure.

  10. Can Measured Synergy Excitations Accurately Construct Unmeasured Muscle Excitations?

    Science.gov (United States)

    Bianco, Nicholas A; Patten, Carolynn; Fregly, Benjamin J

    2018-01-01

    Accurate prediction of muscle and joint contact forces during human movement could improve treatment planning for disorders such as osteoarthritis, stroke, Parkinson's disease, and cerebral palsy. Recent studies suggest that muscle synergies, a low-dimensional representation of a large set of muscle electromyographic (EMG) signals (henceforth called "muscle excitations"), may reduce the redundancy of muscle excitation solutions predicted by optimization methods. This study explores the feasibility of using muscle synergy information extracted from eight muscle EMG signals (henceforth called "included" muscle excitations) to accurately construct muscle excitations from up to 16 additional EMG signals (henceforth called "excluded" muscle excitations). Using treadmill walking data collected at multiple speeds from two subjects (one healthy, one poststroke), we performed muscle synergy analysis on all possible subsets of eight included muscle excitations and evaluated how well the calculated time-varying synergy excitations could construct the remaining excluded muscle excitations (henceforth called "synergy extrapolation"). We found that some, but not all, eight-muscle subsets yielded synergy excitations that achieved >90% extrapolation variance accounted for (VAF). Using the top 10% of subsets, we developed muscle selection heuristics to identify included muscle combinations whose synergy excitations achieved high extrapolation accuracy. For 3, 4, and 5 synergies, these heuristics yielded extrapolation VAF values approximately 5% lower than corresponding reconstruction VAF values for each associated eight-muscle subset. These results suggest that synergy excitations obtained from experimentally measured muscle excitations can accurately construct unmeasured muscle excitations, which could help limit muscle excitations predicted by muscle force optimizations.

  11. Accurate and approximate thermal rate constants for polyatomic chemical reactions

    International Nuclear Information System (INIS)

    Nyman, Gunnar

    2007-01-01

    In favourable cases it is possible to calculate thermal rate constants for polyatomic reactions to high accuracy from first principles. Here, we discuss the use of flux correlation functions combined with the multi-configurational time-dependent Hartree (MCTDH) approach to efficiently calculate cumulative reaction probabilities and thermal rate constants for polyatomic chemical reactions. Three isotopic variants of the H 2 + CH 3 → CH 4 + H reaction are used to illustrate the theory. There is good agreement with experimental results although the experimental rates generally are larger than the calculated ones, which are believed to be at least as accurate as the experimental rates. Approximations allowing evaluation of the thermal rate constant above 400 K are treated. It is also noted that for the treated reactions, transition state theory (TST) gives accurate rate constants above 500 K. TST theory also gives accurate results for kinetic isotope effects in cases where the mass of the transfered atom is unchanged. Due to neglect of tunnelling, TST however fails below 400 K if the mass of the transferred atom changes between the isotopic reactions

  12. Accurate determination of rates from non-uniformly sampled relaxation data

    Energy Technology Data Exchange (ETDEWEB)

    Stetz, Matthew A.; Wand, A. Joshua, E-mail: wand@upenn.edu [University of Pennsylvania Perelman School of Medicine, Johnson Research Foundation and Department of Biochemistry and Biophysics (United States)

    2016-08-15

    The application of non-uniform sampling (NUS) to relaxation experiments traditionally used to characterize the fast internal motion of proteins is quantitatively examined. Experimentally acquired Poisson-gap sampled data reconstructed with iterative soft thresholding are compared to regular sequentially sampled (RSS) data. Using ubiquitin as a model system, it is shown that 25 % sampling is sufficient for the determination of quantitatively accurate relaxation rates. When the sampling density is fixed at 25 %, the accuracy of rates is shown to increase sharply with the total number of sampled points until eventually converging near the inherent reproducibility of the experiment. Perhaps contrary to some expectations, it is found that accurate peak height reconstruction is not required for the determination of accurate rates. Instead, inaccuracies in rates arise from inconsistencies in reconstruction across the relaxation series that primarily manifest as a non-linearity in the recovered peak height. This indicates that the performance of an NUS relaxation experiment cannot be predicted from comparison of peak heights using a single RSS reference spectrum. The generality of these findings was assessed using three alternative reconstruction algorithms, eight different relaxation measurements, and three additional proteins that exhibit varying degrees of spectral complexity. From these data, it is revealed that non-linearity in peak height reconstruction across the relaxation series is strongly correlated with errors in NUS-derived relaxation rates. Importantly, it is shown that this correlation can be exploited to reliably predict the performance of an NUS-relaxation experiment by using three or more RSS reference planes from the relaxation series. The RSS reference time points can also serve to provide estimates of the uncertainty of the sampled intensity, which for a typical relaxation times series incurs no penalty in total acquisition time.

  13. Using In-Service and Coaching to Increase Teachers' Accurate Use of Research-Based Strategies

    Science.gov (United States)

    Kretlow, Allison G.; Cooke, Nancy L.; Wood, Charles L.

    2012-01-01

    Increasing the accurate use of research-based practices in classrooms is a critical issue. Professional development is one of the most practical ways to provide practicing teachers with training related to research-based practices. This study examined the effects of in-service plus follow-up coaching on first grade teachers' accurate delivery of…

  14. Energy providers: customer expectations

    International Nuclear Information System (INIS)

    Pridham, N.F.

    1997-01-01

    The deregulation of the gas and electric power industries, and how it will impact on customer service and pricing rates was discussed. This paper described the present situation, reviewed core competencies, and outlined future expectations. The bottom line is that major energy consumers are very conscious of energy costs and go to great lengths to keep them under control. At the same time, solutions proposed to reduce energy costs must benefit all classes of consumers, be they industrial, commercial, institutional or residential. Deregulation and competition at an accelerated pace is the most likely answer. This may be forced by external forces such as foreign energy providers who are eager to enter the Canadian energy market. It is also likely that the competition and convergence between gas and electricity is just the beginning, and may well be overshadowed by other deregulated industries as they determine their core competencies

  15. Validation of a method for accurate and highly reproducible quantification of brain dopamine transporter SPECT studies

    DEFF Research Database (Denmark)

    Jensen, Peter S; Ziebell, Morten; Skouboe, Glenna

    2011-01-01

    In nuclear medicine brain imaging, it is important to delineate regions of interest (ROIs) so that the outcome is both accurate and reproducible. The purpose of this study was to validate a new time-saving algorithm (DATquan) for accurate and reproducible quantification of the striatal dopamine t...... transporter (DAT) with appropriate radioligands and SPECT and without the need for structural brain scanning....

  16. Smart and accurate state-of-charge indication in portable applications

    NARCIS (Netherlands)

    Pop, V.; Bergveld, H.J.; Notten, P.H.L.; Regtien, P.P.L.

    2005-01-01

    Accurate state-of-charge (SoC) and remaining run-time indication for portable devices is important for the user-convenience and to prolong the lifetime of batteries. However, the known methods of SoC indication in portable applications are not accurate enough under all practical conditions. The

  17. Smart and accurate State-of-Charge indication in Portable Applications

    NARCIS (Netherlands)

    Pop, V.; Bergveld, H.J.; Notten, P.H.L.; Regtien, Paulus P.L.

    2006-01-01

    Accurate state-of-charge (SoC) and remaining run-time indication for portable devices is important for the user-convenience and to prolong the lifetime of batteries. However, the known methods of SoC indication in portable applications are not accurate enough under all practical conditions. The

  18. Geometric information provider platform

    Directory of Open Access Journals (Sweden)

    Meisam Yousefzadeh

    2015-07-01

    Full Text Available Renovation of existing buildings is known as an essential stage in reduction of the energy loss. Considerable part of renovation process depends on geometric reconstruction of building based on semantic parameters. Following many research projects which were focused on parameterizing the energy usage, various energy modelling methods were developed during the last decade. On the other hand, by developing accurate measuring tools such as laser scanners, the interests of having accurate 3D building models are rapidly growing. But the automation of 3D building generation from laser point cloud or detection of specific objects in that is still a challenge.  The goal is designing a platform through which required geometric information can be efficiently produced to support energy simulation software. Developing a reliable procedure which extracts required information from measured data and delivers them to a standard energy modelling system is the main purpose of the project.

  19. Accurate Classification of Chronic Migraine via Brain Magnetic Resonance Imaging

    Science.gov (United States)

    Schwedt, Todd J.; Chong, Catherine D.; Wu, Teresa; Gaw, Nathan; Fu, Yinlin; Li, Jing

    2015-01-01

    Background The International Classification of Headache Disorders provides criteria for the diagnosis and subclassification of migraine. Since there is no objective gold standard by which to test these diagnostic criteria, the criteria are based on the consensus opinion of content experts. Accurate migraine classifiers consisting of brain structural measures could serve as an objective gold standard by which to test and revise diagnostic criteria. The objectives of this study were to utilize magnetic resonance imaging measures of brain structure for constructing classifiers: 1) that accurately identify individuals as having chronic vs. episodic migraine vs. being a healthy control; and 2) that test the currently used threshold of 15 headache days/month for differentiating chronic migraine from episodic migraine. Methods Study participants underwent magnetic resonance imaging for determination of regional cortical thickness, cortical surface area, and volume. Principal components analysis combined structural measurements into principal components accounting for 85% of variability in brain structure. Models consisting of these principal components were developed to achieve the classification objectives. Ten-fold cross validation assessed classification accuracy within each of the ten runs, with data from 90% of participants randomly selected for classifier development and data from the remaining 10% of participants used to test classification performance. Headache frequency thresholds ranging from 5–15 headache days/month were evaluated to determine the threshold allowing for the most accurate subclassification of individuals into lower and higher frequency subgroups. Results Participants were 66 migraineurs and 54 healthy controls, 75.8% female, with an average age of 36 +/− 11 years. Average classifier accuracies were: a) 68% for migraine (episodic + chronic) vs. healthy controls; b) 67.2% for episodic migraine vs. healthy controls; c) 86.3% for chronic

  20. Accurate ocean bottom seismometer positioning method inspired by multilateration technique

    Science.gov (United States)

    Benazzouz, Omar; Pinheiro, Luis M.; Matias, Luis M. A.; Afilhado, Alexandra; Herold, Daniel; Haines, Seth S.

    2018-01-01

    The positioning of ocean bottom seismometers (OBS) is a key step in the processing flow of OBS data, especially in the case of self popup types of OBS instruments. The use of first arrivals from airgun shots, rather than relying on the acoustic transponders mounted in the OBS, is becoming a trend and generally leads to more accurate positioning due to the statistics from a large number of shots. In this paper, a linearization of the OBS positioning problem via the multilateration technique is discussed. The discussed linear solution solves jointly for the average water layer velocity and the OBS position using only shot locations and first arrival times as input data.

  1. Accurate 3D reconstruction by a new PDS-OSEM algorithm for HRRT

    International Nuclear Information System (INIS)

    Chen, Tai-Been; Horng-Shing Lu, Henry; Kim, Hang-Keun; Son, Young-Don; Cho, Zang- Hee

    2014-01-01

    State-of-the-art high resolution research tomography (HRRT) provides high resolution PET images with full 3D human brain scanning. But, a short time frame in dynamic study causes many problems related to the low counts in the acquired data. The PDS-OSEM algorithm was proposed to reconstruct the HRRT image with a high signal-to-noise ratio that provides accurate information for dynamic data. The new algorithm was evaluated by simulated image, empirical phantoms, and real human brain data. Meanwhile, the time activity curve was adopted to validate a reconstructed performance of dynamic data between PDS-OSEM and OP-OSEM algorithms. According to simulated and empirical studies, the PDS-OSEM algorithm reconstructs images with higher quality, higher accuracy, less noise, and less average sum of square error than those of OP-OSEM. The presented algorithm is useful to provide quality images under the condition of low count rates in dynamic studies with a short scan time. - Highlights: • The PDS-OSEM reconstructs PET images with iteratively compensating random and scatter corrections from prompt sinogram. • The PDS-OSEM can reconstruct PET images with low count data and data contaminations. • The PDS-OSEM provides less noise and higher quality of reconstructed images than those of OP-OSEM algorithm in statistical sense

  2. Accurate measurements of neutron activation cross sections

    International Nuclear Information System (INIS)

    Semkova, V.

    1999-01-01

    The applications of some recent achievements of neutron activation method on high intensity neutron sources are considered from the view point of associated errors of cross sections data for neutron induced reaction. The important corrections in -y-spectrometry insuring precise determination of the induced radioactivity, methods for accurate determination of the energy and flux density of neutrons, produced by different sources, and investigations of deuterium beam composition are considered as factors determining the precision of the experimental data. The influence of the ion beam composition on the mean energy of neutrons has been investigated by measurement of the energy of neutrons induced by different magnetically analysed deuterium ion groups. Zr/Nb method for experimental determination of the neutron energy in the 13-15 MeV energy range allows to measure energy of neutrons from D-T reaction with uncertainty of 50 keV. Flux density spectra from D(d,n) E d = 9.53 MeV and Be(d,n) E d = 9.72 MeV are measured by PHRS and foil activation method. Future applications of the activation method on NG-12 are discussed. (author)

  3. A stiffly accurate integrator for elastodynamic problems

    KAUST Repository

    Michels, Dominik L.

    2017-07-21

    We present a new integration algorithm for the accurate and efficient solution of stiff elastodynamic problems governed by the second-order ordinary differential equations of structural mechanics. Current methods have the shortcoming that their performance is highly dependent on the numerical stiffness of the underlying system that often leads to unrealistic behavior or a significant loss of efficiency. To overcome these limitations, we present a new integration method which is based on a mathematical reformulation of the underlying differential equations, an exponential treatment of the full nonlinear forcing operator as opposed to more standard partially implicit or exponential approaches, and the utilization of the concept of stiff accuracy which ensures that the efficiency of the simulations is significantly less sensitive to increased stiffness. As a consequence, we are able to tremendously accelerate the simulation of stiff systems compared to established integrators and significantly increase the overall accuracy. The advantageous behavior of this approach is demonstrated on a broad spectrum of complex examples like deformable bodies, textiles, bristles, and human hair. Our easily parallelizable integrator enables more complex and realistic models to be explored in visual computing without compromising efficiency.

  4. Geodetic analysis of disputed accurate qibla direction

    Science.gov (United States)

    Saksono, Tono; Fulazzaky, Mohamad Ali; Sari, Zamah

    2018-04-01

    Muslims perform the prayers facing towards the correct qibla direction would be the only one of the practical issues in linking theoretical studies with practice. The concept of facing towards the Kaaba in Mecca during the prayers has long been the source of controversy among the muslim communities to not only in poor and developing countries but also in developed countries. The aims of this study were to analyse the geodetic azimuths of qibla calculated using three different models of the Earth. The use of ellipsoidal model of the Earth could be the best method for determining the accurate direction of Kaaba from anywhere on the Earth's surface. A muslim cannot direct himself towards the qibla correctly if he cannot see the Kaaba due to setting out process and certain motions during the prayer this can significantly shift the qibla direction from the actual position of the Kaaba. The requirement of muslim prayed facing towards the Kaaba is more as spiritual prerequisite rather than physical evidence.

  5. Therapy Provider Phase Information

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Therapy Provider Phase Information dataset is a tool for providers to search by their National Provider Identifier (NPI) number to determine their phase for...

  6. Fast and Accurate Prediction of Stratified Steel Temperature During Holding Period of Ladle

    Science.gov (United States)

    Deodhar, Anirudh; Singh, Umesh; Shukla, Rishabh; Gautham, B. P.; Singh, Amarendra K.

    2017-04-01

    Thermal stratification of liquid steel in a ladle during the holding period and the teeming operation has a direct bearing on the superheat available at the caster and hence on the caster set points such as casting speed and cooling rates. The changes in the caster set points are typically carried out based on temperature measurements at the end of tundish outlet. Thermal prediction models provide advance knowledge of the influence of process and design parameters on the steel temperature at various stages. Therefore, they can be used in making accurate decisions about the caster set points in real time. However, this requires both fast and accurate thermal prediction models. In this work, we develop a surrogate model for the prediction of thermal stratification using data extracted from a set of computational fluid dynamics (CFD) simulations, pre-determined using design of experiments technique. Regression method is used for training the predictor. The model predicts the stratified temperature profile instantaneously, for a given set of process parameters such as initial steel temperature, refractory heat content, slag thickness, and holding time. More than 96 pct of the predicted values are within an error range of ±5 K (±5 °C), when compared against corresponding CFD results. Considering its accuracy and computational efficiency, the model can be extended for thermal control of casting operations. This work also sets a benchmark for developing similar thermal models for downstream processes such as tundish and caster.

  7. Accurate measurement of mitochondrial DNA deletion level and copy number differences in human skeletal muscle.

    Directory of Open Access Journals (Sweden)

    John P Grady

    Full Text Available Accurate and reliable quantification of the abundance of mitochondrial DNA (mtDNA molecules, both wild-type and those harbouring pathogenic mutations, is important not only for understanding the progression of mtDNA disease but also for evaluating novel therapeutic approaches. A clear understanding of the sensitivity of mtDNA measurement assays under different experimental conditions is therefore critical, however it is routinely lacking for most published mtDNA quantification assays. Here, we comprehensively assess the variability of two quantitative Taqman real-time PCR assays, a widely-applied MT-ND1/MT-ND4 multiplex mtDNA deletion assay and a recently developed MT-ND1/B2M singleplex mtDNA copy number assay, across a range of DNA concentrations and mtDNA deletion/copy number levels. Uniquely, we provide a specific guide detailing necessary numbers of sample and real-time PCR plate replicates for accurately and consistently determining a given difference in mtDNA deletion levels and copy number in homogenate skeletal muscle DNA.

  8. Quality metric for accurate overlay control in <20nm nodes

    Science.gov (United States)

    Klein, Dana; Amit, Eran; Cohen, Guy; Amir, Nuriel; Har-Zvi, Michael; Huang, Chin-Chou Kevin; Karur-Shanmugam, Ramkumar; Pierson, Bill; Kato, Cindy; Kurita, Hiroyuki

    2013-04-01

    The semiconductor industry is moving toward 20nm nodes and below. As the Overlay (OVL) budget is getting tighter at these advanced nodes, the importance in the accuracy in each nanometer of OVL error is critical. When process owners select OVL targets and methods for their process, they must do it wisely; otherwise the reported OVL could be inaccurate, resulting in yield loss. The same problem can occur when the target sampling map is chosen incorrectly, consisting of asymmetric targets that will cause biased correctable terms and a corrupted wafer. Total measurement uncertainty (TMU) is the main parameter that process owners use when choosing an OVL target per layer. Going towards the 20nm nodes and below, TMU will not be enough for accurate OVL control. KLA-Tencor has introduced a quality score named `Qmerit' for its imaging based OVL (IBO) targets, which is obtained on the-fly for each OVL measurement point in X & Y. This Qmerit score will enable the process owners to select compatible targets which provide accurate OVL values for their process and thereby improve their yield. Together with K-T Analyzer's ability to detect the symmetric targets across the wafer and within the field, the Archer tools will continue to provide an independent, reliable measurement of OVL error into the next advanced nodes, enabling fabs to manufacture devices that meet their tight OVL error budgets.

  9. KFM: a homemade yet accurate and dependable fallout meter

    International Nuclear Information System (INIS)

    Kearny, C.H.; Barnes, P.R.; Chester, C.V.; Cortner, M.W.

    1978-01-01

    The KFM is a homemade fallout meter that can be made using only materials, tools, and skills found in millions of American homes. It is an accurate and dependable electroscope-capacitor. The KFM, in conjunction with its attached table and a watch, is designed for use as a rate meter. Its attached table relates observed differences in the separations of its two leaves (before and after exposures at the listed time intervals) to the dose rates during exposures of these time intervals. In this manner dose rates from 30 mR/hr up to 43 R/hr can be determined with an accuracy of +-25%. A KFM can be charged with any one of the three expedient electrostatic charging devices described. Due to the use of anhydrite (made by heating gypsum from wallboard) inside a KFM and the expedient ''dry-bucket'' in which it can be charged when the air is very humid, this instrument always can be charged and used to obtain accurate measurements of gamma radiation no matter how high the relative humidity. The step-by-step illustrated instructions for making and using a KFM are presented. These instructions have been improved after each successive field test. The majority of the untrained test families, adequately motivated by cash bonuses offered for success and guided only by these written instructions, have succeeded in making and using a KFM

  10. Towards Accurate Application Characterization for Exascale (APEX)

    Energy Technology Data Exchange (ETDEWEB)

    Hammond, Simon David [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    Sandia National Laboratories has been engaged in hardware and software codesign activities for a number of years, indeed, it might be argued that prototyping of clusters as far back as the CPLANT machines and many large capability resources including ASCI Red and RedStorm were examples of codesigned solutions. As the research supporting our codesign activities has moved closer to investigating on-node runtime behavior a nature hunger has grown for detailed analysis of both hardware and algorithm performance from the perspective of low-level operations. The Application Characterization for Exascale (APEX) LDRD was a project concieved of addressing some of these concerns. Primarily the research was to intended to focus on generating accurate and reproducible low-level performance metrics using tools that could scale to production-class code bases. Along side this research was an advocacy and analysis role associated with evaluating tools for production use, working with leading industry vendors to develop and refine solutions required by our code teams and to directly engage with production code developers to form a context for the application analysis and a bridge to the research community within Sandia. On each of these accounts significant progress has been made, particularly, as this report will cover, in the low-level analysis of operations for important classes of algorithms. This report summarizes the development of a collection of tools under the APEX research program and leaves to other SAND and L2 milestone reports the description of codesign progress with Sandia’s production users/developers.

  11. How flatbed scanners upset accurate film dosimetry

    Science.gov (United States)

    van Battum, L. J.; Huizenga, H.; Verdaasdonk, R. M.; Heukelom, S.

    2016-01-01

    Film is an excellent dosimeter for verification of dose distributions due to its high spatial resolution. Irradiated film can be digitized with low-cost, transmission, flatbed scanners. However, a disadvantage is their lateral scan effect (LSE): a scanner readout change over its lateral scan axis. Although anisotropic light scattering was presented as the origin of the LSE, this paper presents an alternative cause. Hereto, LSE for two flatbed scanners (Epson 1680 Expression Pro and Epson 10000XL), and Gafchromic film (EBT, EBT2, EBT3) was investigated, focused on three effects: cross talk, optical path length and polarization. Cross talk was examined using triangular sheets of various optical densities. The optical path length effect was studied using absorptive and reflective neutral density filters with well-defined optical characteristics (OD range 0.2-2.0). Linear polarizer sheets were used to investigate light polarization on the CCD signal in absence and presence of (un)irradiated Gafchromic film. Film dose values ranged between 0.2 to 9 Gy, i.e. an optical density range between 0.25 to 1.1. Measurements were performed in the scanner’s transmission mode, with red-green-blue channels. LSE was found to depend on scanner construction and film type. Its magnitude depends on dose: for 9 Gy increasing up to 14% at maximum lateral position. Cross talk was only significant in high contrast regions, up to 2% for very small fields. The optical path length effect introduced by film on the scanner causes 3% for pixels in the extreme lateral position. Light polarization due to film and the scanner’s optical mirror system is the main contributor, different in magnitude for the red, green and blue channel. We concluded that any Gafchromic EBT type film scanned with a flatbed scanner will face these optical effects. Accurate dosimetry requires correction of LSE, therefore, determination of the LSE per color channel and dose delivered to the film.

  12. Accurate hydrocarbon estimates attained with radioactive isotope

    International Nuclear Information System (INIS)

    Hubbard, G.

    1983-01-01

    To make accurate economic evaluations of new discoveries, an oil company needs to know how much gas and oil a reservoir contains. The porous rocks of these reservoirs are not completely filled with gas or oil, but contain a mixture of gas, oil and water. It is extremely important to know what volume percentage of this water--called connate water--is contained in the reservoir rock. The percentage of connate water can be calculated from electrical resistivity measurements made downhole. The accuracy of this method can be improved if a pure sample of connate water can be analyzed or if the chemistry of the water can be determined by conventional logging methods. Because of the similarity of the mud filtrate--the water in a water-based drilling fluid--and the connate water, this is not always possible. If the oil company cannot distinguish between connate water and mud filtrate, its oil-in-place calculations could be incorrect by ten percent or more. It is clear that unless an oil company can be sure that a sample of connate water is pure, or at the very least knows exactly how much mud filtrate it contains, its assessment of the reservoir's water content--and consequently its oil or gas content--will be distorted. The oil companies have opted for the Repeat Formation Tester (RFT) method. Label the drilling fluid with small doses of tritium--a radioactive isotope of hydrogen--and it will be easy to detect and quantify in the sample

  13. How flatbed scanners upset accurate film dosimetry

    International Nuclear Information System (INIS)

    Van Battum, L J; Verdaasdonk, R M; Heukelom, S; Huizenga, H

    2016-01-01

    Film is an excellent dosimeter for verification of dose distributions due to its high spatial resolution. Irradiated film can be digitized with low-cost, transmission, flatbed scanners. However, a disadvantage is their lateral scan effect (LSE): a scanner readout change over its lateral scan axis. Although anisotropic light scattering was presented as the origin of the LSE, this paper presents an alternative cause. Hereto, LSE for two flatbed scanners (Epson 1680 Expression Pro and Epson 10000XL), and Gafchromic film (EBT, EBT2, EBT3) was investigated, focused on three effects: cross talk, optical path length and polarization. Cross talk was examined using triangular sheets of various optical densities. The optical path length effect was studied using absorptive and reflective neutral density filters with well-defined optical characteristics (OD range 0.2–2.0). Linear polarizer sheets were used to investigate light polarization on the CCD signal in absence and presence of (un)irradiated Gafchromic film. Film dose values ranged between 0.2 to 9 Gy, i.e. an optical density range between 0.25 to 1.1. Measurements were performed in the scanner’s transmission mode, with red–green–blue channels. LSE was found to depend on scanner construction and film type. Its magnitude depends on dose: for 9 Gy increasing up to 14% at maximum lateral position. Cross talk was only significant in high contrast regions, up to 2% for very small fields. The optical path length effect introduced by film on the scanner causes 3% for pixels in the extreme lateral position. Light polarization due to film and the scanner’s optical mirror system is the main contributor, different in magnitude for the red, green and blue channel. We concluded that any Gafchromic EBT type film scanned with a flatbed scanner will face these optical effects. Accurate dosimetry requires correction of LSE, therefore, determination of the LSE per color channel and dose delivered to the film. (paper)

  14. What HERA May Provide?

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hannes; /DESY; De Roeck, Albert; /CERN; Bartels, Jochen; /Hamburg U., Inst. Theor. Phys. II; Behnke, Olaf; Blumlein, Johannes; /DESY; Brodsky, Stanley; /SLAC /Durham U., IPPP; Cooper-Sarkar, Amanda; /Oxford U.; Deak, Michal; /DESY; Devenish, Robin; /Oxford U.; Diehl, Markus; /DESY; Gehrmann, Thomas; /Zurich U.; Grindhammer, Guenter; /Munich, Max Planck Inst.; Gustafson, Gosta; /CERN /Lund U., Dept. Theor. Phys.; Khoze, Valery; /Durham U., IPPP; Knutsson, Albert; /DESY; Klein, Max; /Liverpool U.; Krauss, Frank; /Durham U., IPPP; Kutak, Krzysztof; /DESY; Laenen, Eric; /NIKHEF, Amsterdam; Lonnblad, Leif; /Lund U., Dept. Theor. Phys.; Motyka, Leszek; /Hamburg U., Inst. Theor. Phys. II /Birmingham U. /Southern Methodist U. /DESY /Piemonte Orientale U., Novara /CERN /Paris, LPTHE /Hamburg U. /Penn State U.

    2011-11-10

    More than 100 people participated in a discussion session at the DIS08 workshop on the topic What HERA may provide. A summary of the discussion with a structured outlook and list of desirable measurements and theory calculations is given. The HERA accelerator and the HERA experiments H1, HERMES and ZEUS stopped running in the end of June 2007. This was after 15 years of very successful operation since the first collisions in 1992. A total luminosity of {approx} 500 pb{sup -1} has been accumulated by each of the collider experiments H1 and ZEUS. During the years the increasingly better understood and upgraded detectors and HERA accelerator have contributed significantly to this success. The physics program remains in full swing and plenty of new results were presented at DIS08 which are approaching the anticipated final precision, fulfilling and exceeding the physics plans and the previsions of the upgrade program. Most of the analyses presented at DIS08 were still based on the so called HERA I data sample, i.e. data taken until 2000, before the shutdown for the luminosity upgrade. This sample has an integrated luminosity of {approx} 100 pb{sup -1}, and the four times larger statistics sample from HERA II is still in the process of being analyzed.

  15. Radio Astronomers Set New Standard for Accurate Cosmic Distance Measurement

    Science.gov (United States)

    1999-06-01

    estimate of the age of the universe. In order to do this, you need an unambiguous, absolute distance to another galaxy. We are pleased that the NSF's VLBA has for the first time determined such a distance, and thus provided the calibration standard astronomers have always sought in their quest for accurate distances beyond the Milky Way," said Morris Aizenman, Executive Officer of the National Science Foundation's (NSF) Division of Astronomical Sciences. "For astronomers, this measurement is the golden meter stick in the glass case," Aizenman added. The international team of astronomers used the VLBA to measure directly the motion of gas orbiting what is generally agreed to be a supermassive black hole at the heart of NGC 4258. The orbiting gas forms a warped disk, nearly two light-years in diameter, surrounding the black hole. The gas in the disk includes water vapor, which, in parts of the disk, acts as a natural amplifier of microwave radio emission. The regions that amplify radio emission are called masers, and work in a manner similar to the way a laser amplifies light emission. Determining the distance to NGC 4258 required measuring motions of extremely small shifts in position of these masers as they rotate around the black hole. This is equivalent to measuring an angle one ten-thousandth the width of a human hair held at arm's length. "The VLBA is the only instrument in the world that could do this," said Moran. "This work is the culmination of a 20-year effort at the Harvard Smithsonian Center for Astrophysics to measure distances to cosmic masers," said Irwin Shapiro, Director of that institution. Collection of the data for the NGC 4258 project was begun in 1994 and was part of Herrnstein's Ph.D dissertation at Harvard University. Previous observations with the VLBA allowed the scientists to measure the speed at which the gas is orbiting the black hole, some 39 million times more massive than the Sun. They did this by observing the amount of change in the

  16. Accurate 3D reconstruction by a new PDS-OSEM algorithm for HRRT

    Science.gov (United States)

    Chen, Tai-Been; Horng-Shing Lu, Henry; Kim, Hang-Keun; Son, Young-Don; Cho, Zang-Hee

    2014-03-01

    State-of-the-art high resolution research tomography (HRRT) provides high resolution PET images with full 3D human brain scanning. But, a short time frame in dynamic study causes many problems related to the low counts in the acquired data. The PDS-OSEM algorithm was proposed to reconstruct the HRRT image with a high signal-to-noise ratio that provides accurate information for dynamic data. The new algorithm was evaluated by simulated image, empirical phantoms, and real human brain data. Meanwhile, the time activity curve was adopted to validate a reconstructed performance of dynamic data between PDS-OSEM and OP-OSEM algorithms. According to simulated and empirical studies, the PDS-OSEM algorithm reconstructs images with higher quality, higher accuracy, less noise, and less average sum of square error than those of OP-OSEM. The presented algorithm is useful to provide quality images under the condition of low count rates in dynamic studies with a short scan time.

  17. Fast and accurate determination of modularity and its effect size

    International Nuclear Information System (INIS)

    Treviño, Santiago III; Nyberg, Amy; Bassler, Kevin E; Del Genio, Charo I

    2015-01-01

    We present a fast spectral algorithm for community detection in complex networks. Our method searches for the partition with the maximum value of the modularity via the interplay of several refinement steps that include both agglomeration and division. We validate the accuracy of the algorithm by applying it to several real-world benchmark networks. On all these, our algorithm performs as well or better than any other known polynomial scheme. This allows us to extensively study the modularity distribution in ensembles of Erdős–Rényi networks, producing theoretical predictions for means and variances inclusive of finite-size corrections. Our work provides a way to accurately estimate the effect size of modularity, providing a z-score measure of it and enabling a more informative comparison of networks with different numbers of nodes and links. (paper)

  18. Anatomically accurate, finite model eye for optical modeling.

    Science.gov (United States)

    Liou, H L; Brennan, N A

    1997-08-01

    There is a need for a schematic eye that models vision accurately under various conditions such as refractive surgical procedures, contact lens and spectacle wear, and near vision. Here we propose a new model eye close to anatomical, biometric, and optical realities. This is a finite model with four aspheric refracting surfaces and a gradient-index lens. It has an equivalent power of 60.35 D and an axial length of 23.95 mm. The new model eye provides spherical aberration values within the limits of empirical results and predicts chromatic aberration for wavelengths between 380 and 750 nm. It provides a model for calculating optical transfer functions and predicting optical performance of the eye.

  19. A Modified Proportional Navigation Guidance for Accurate Target Hitting

    Directory of Open Access Journals (Sweden)

    A. Moharampour

    2010-03-01

    First, the pure proportional navigation guidance (PPNG in 3-dimensional state is explained in a new point of view. The main idea is based on the distinction between angular rate vector and rotation vector conceptions. The current innovation is based on selection of line of sight (LOS coordinates. A comparison between two available choices for LOS coordinates system is proposed. An improvement is made by adding two additional terms. First term includes a cross range compensator which is used to provide and enhance path observability, and obtain convergent estimates of state variables. The second term is new concept lead bias term, which has been calculated by assuming an equivalent acceleration along the target longitudinal axis. Simulation results indicate that the lead bias term properly provides terminal conditions for accurate target interception.

  20. Visibility in health statistics: a population data linkage study more accurately identifying Aboriginal and Torres Strait Islander Births in Victoria, Australia, 1988-2008

    Directory of Open Access Journals (Sweden)

    Rebecca Ritte

    2017-04-01

    This is the first time that the VPDC and RBDM birth data were linked in Victoria. The matched birth information established a more complete population profile of Aboriginal and/or Torres Strait Islander births. These data will provide a more accurate baseline to enhance the Victorian and Australian governments’ ability to plan services, allocate resources and evaluate funded activities aimed at eliminating disparity experienced by Aboriginal and/or Torres Strait Islander peoples. Importantly, it has established a more accurate denominator from which to calculate Aboriginal infant mortality rates for Victoria, Australia. *Until 2009, the mother’s Indigenous identification only was recorded in the VPDC

  1. Twitter for travel medicine providers.

    Science.gov (United States)

    Mills, Deborah J; Kohl, Sarah E

    2016-03-01

    Travel medicine practitioners, perhaps more so than medical practitioners working in other areas of medicine, require a constant flow of information to stay up-to-date, and provide best practice information and care to their patients. Many travel medicine providers are unaware of the popularity and potential of the Twitter platform. Twitter use among our travellers, as well as by physicians and health providers, is growing exponentially. There is a rapidly expanding body of published literature on this information tool. This review provides a brief overview of the ways Twitter is being used by health practitioners, the advantages that are peculiar to Twitter as a platform of social media, and how the interested practitioner can get started. Some key points about the dark side of Twitter are highlighted, as well as the potential benefits of using Twitter as a way to disseminate accurate medical information to the public. This article will help readers develop an increased understanding of Twitter as a tool for extracting useful facts and insights from the ever increasing volume of health information. © International Society of Travel Medicine, 2016. All rights reserved. Published by Oxford University Press. For permissions, please e-mail: journals.permissions@oup.com.

  2. Sampling designs matching species biology produce accurate and affordable abundance indices.

    Science.gov (United States)

    Harris, Grant; Farley, Sean; Russell, Gareth J; Butler, Matthew J; Selinger, Jeff

    2013-01-01

    , which raised capture probabilities. The grid design was least biased (-10.5%), but imprecise (CV 21.2%), and used most effort (16,100 trap-nights). The targeted configuration was more biased (-17.3%), but most precise (CV 12.3%), with least effort (7,000 trap-nights). Targeted sampling generated encounter rates four times higher, and capture and recapture probabilities 11% and 60% higher than grid sampling, in a sampling frame 88% smaller. Bears had unequal probability of capture with both sampling designs, partly because some bears never had traps available to sample them. Hence, grid and targeted sampling generated abundance indices, not estimates. Overall, targeted sampling provided the most accurate and affordable design to index abundance. Targeted sampling may offer an alternative method to index the abundance of other species inhabiting expansive and inaccessible landscapes elsewhere, provided their attraction to resource concentrations.

  3. Sampling designs matching species biology produce accurate and affordable abundance indices

    Directory of Open Access Journals (Sweden)

    Grant Harris

    2013-12-01

    sessions, which raised capture probabilities. The grid design was least biased (−10.5%, but imprecise (CV 21.2%, and used most effort (16,100 trap-nights. The targeted configuration was more biased (−17.3%, but most precise (CV 12.3%, with least effort (7,000 trap-nights. Targeted sampling generated encounter rates four times higher, and capture and recapture probabilities 11% and 60% higher than grid sampling, in a sampling frame 88% smaller. Bears had unequal probability of capture with both sampling designs, partly because some bears never had traps available to sample them. Hence, grid and targeted sampling generated abundance indices, not estimates. Overall, targeted sampling provided the most accurate and affordable design to index abundance. Targeted sampling may offer an alternative method to index the abundance of other species inhabiting expansive and inaccessible landscapes elsewhere, provided their attraction to resource concentrations.

  4. Sampling designs matching species biology produce accurate and affordable abundance indices

    Science.gov (United States)

    Farley, Sean; Russell, Gareth J.; Butler, Matthew J.; Selinger, Jeff

    2013-01-01

    raised capture probabilities. The grid design was least biased (−10.5%), but imprecise (CV 21.2%), and used most effort (16,100 trap-nights). The targeted configuration was more biased (−17.3%), but most precise (CV 12.3%), with least effort (7,000 trap-nights). Targeted sampling generated encounter rates four times higher, and capture and recapture probabilities 11% and 60% higher than grid sampling, in a sampling frame 88% smaller. Bears had unequal probability of capture with both sampling designs, partly because some bears never had traps available to sample them. Hence, grid and targeted sampling generated abundance indices, not estimates. Overall, targeted sampling provided the most accurate and affordable design to index abundance. Targeted sampling may offer an alternative method to index the abundance of other species inhabiting expansive and inaccessible landscapes elsewhere, provided their attraction to resource concentrations. PMID:24392290

  5. Medical service provider networks.

    Science.gov (United States)

    Mougeot, Michel; Naegelen, Florence

    2018-05-17

    In many countries, health insurers or health plans choose to contract either with any willing providers or with preferred providers. We compare these mechanisms when two medical services are imperfect substitutes in demand and are supplied by two different firms. In both cases, the reimbursement is higher when patients select the in-network provider(s). We show that these mechanisms yield lower prices, lower providers' and insurer's profits, and lower expense than in the uniform-reimbursement case. Whatever the degree of product differentiation, a not-for-profit insurer should prefer selective contracting and select a reimbursement such that the out-of-pocket expense is null. Although all providers join the network under any-willing-provider contracting in the absence of third-party payment, an asymmetric equilibrium may exist when this billing arrangement is implemented. Copyright © 2018 John Wiley & Sons, Ltd.

  6. How accurately can 21cm tomography constrain cosmology?

    Science.gov (United States)

    Mao, Yi; Tegmark, Max; McQuinn, Matthew; Zaldarriaga, Matias; Zahn, Oliver

    2008-07-01

    There is growing interest in using 3-dimensional neutral hydrogen mapping with the redshifted 21 cm line as a cosmological probe. However, its utility depends on many assumptions. To aid experimental planning and design, we quantify how the precision with which cosmological parameters can be measured depends on a broad range of assumptions, focusing on the 21 cm signal from 6noise, to uncertainties in the reionization history, and to the level of contamination from astrophysical foregrounds. We derive simple analytic estimates for how various assumptions affect an experiment’s sensitivity, and we find that the modeling of reionization is the most important, followed by the array layout. We present an accurate yet robust method for measuring cosmological parameters that exploits the fact that the ionization power spectra are rather smooth functions that can be accurately fit by 7 phenomenological parameters. We find that for future experiments, marginalizing over these nuisance parameters may provide constraints almost as tight on the cosmology as if 21 cm tomography measured the matter power spectrum directly. A future square kilometer array optimized for 21 cm tomography could improve the sensitivity to spatial curvature and neutrino masses by up to 2 orders of magnitude, to ΔΩk≈0.0002 and Δmν≈0.007eV, and give a 4σ detection of the spectral index running predicted by the simplest inflation models.

  7. Canadian consumer issues in accurate and fair electricity metering

    International Nuclear Information System (INIS)

    2000-07-01

    The Public Interest Advocacy Centre (PIAC), located in Ottawa, participates in regulatory proceedings concerning electricity and natural gas to support public and consumer interest. PIAC provides legal representation, research and policy support and public advocacy. A study aimed toward the determination of the issues at stake for residential electricity consumers in the provision of fair and accurate electricity metering, was commissioned by Measurement Canada in consultation with Industry Canada's Consumer Affairs. The metering of electricity must be carried out in a fair and efficient manner for all residential consumers. The Electricity, Gas and Inspection Act was developed to ensure compliance with standards for measuring instrumentation. The accurate metering of electricity through the distribution systems for electricity in Canada represents the main focus of this study and report. The role played by Measurement Canada and the increased efficiencies of service delivery by Measurement Canada or the changing of electricity market conditions are of special interest. The role of Measurement Canada was explained, as were the concerns of residential consumers. A comparison was then made between the interests of residential consumers and those of commercial and industrial electricity consumers in electricity metering. Selected American and Commonwealth jurisdictions were reviewed in light of their electricity metering practices. A section on compliance and conflict resolution was included, in addition to a section on the use of voluntary codes for compliance and conflict resolution

  8. A practical method for accurate quantification of large fault trees

    International Nuclear Information System (INIS)

    Choi, Jong Soo; Cho, Nam Zin

    2007-01-01

    This paper describes a practical method to accurately quantify top event probability and importance measures from incomplete minimal cut sets (MCS) of a large fault tree. The MCS-based fault tree method is extensively used in probabilistic safety assessments. Several sources of uncertainties exist in MCS-based fault tree analysis. The paper is focused on quantification of the following two sources of uncertainties: (1) the truncation neglecting low-probability cut sets and (2) the approximation in quantifying MCSs. The method proposed in this paper is based on a Monte Carlo simulation technique to estimate probability of the discarded MCSs and the sum of disjoint products (SDP) approach complemented by the correction factor approach (CFA). The method provides capability to accurately quantify the two uncertainties and estimate the top event probability and importance measures of large coherent fault trees. The proposed fault tree quantification method has been implemented in the CUTREE code package and is tested on the two example fault trees

  9. Accurate Multisteps Traffic Flow Prediction Based on SVM

    Directory of Open Access Journals (Sweden)

    Zhang Mingheng

    2013-01-01

    Full Text Available Accurate traffic flow prediction is prerequisite and important for realizing intelligent traffic control and guidance, and it is also the objective requirement for intelligent traffic management. Due to the strong nonlinear, stochastic, time-varying characteristics of urban transport system, artificial intelligence methods such as support vector machine (SVM are now receiving more and more attentions in this research field. Compared with the traditional single-step prediction method, the multisteps prediction has the ability that can predict the traffic state trends over a certain period in the future. From the perspective of dynamic decision, it is far important than the current traffic condition obtained. Thus, in this paper, an accurate multi-steps traffic flow prediction model based on SVM was proposed. In which, the input vectors were comprised of actual traffic volume and four different types of input vectors were compared to verify their prediction performance with each other. Finally, the model was verified with actual data in the empirical analysis phase and the test results showed that the proposed SVM model had a good ability for traffic flow prediction and the SVM-HPT model outperformed the other three models for prediction.

  10. Accurate phylogenetic classification of DNA fragments based onsequence composition

    Energy Technology Data Exchange (ETDEWEB)

    McHardy, Alice C.; Garcia Martin, Hector; Tsirigos, Aristotelis; Hugenholtz, Philip; Rigoutsos, Isidore

    2006-05-01

    Metagenome studies have retrieved vast amounts of sequenceout of a variety of environments, leading to novel discoveries and greatinsights into the uncultured microbial world. Except for very simplecommunities, diversity makes sequence assembly and analysis a verychallenging problem. To understand the structure a 5 nd function ofmicrobial communities, a taxonomic characterization of the obtainedsequence fragments is highly desirable, yet currently limited mostly tothose sequences that contain phylogenetic marker genes. We show that forclades at the rank of domain down to genus, sequence composition allowsthe very accurate phylogenetic 10 characterization of genomic sequence.We developed a composition-based classifier, PhyloPythia, for de novophylogenetic sequence characterization and have trained it on adata setof 340 genomes. By extensive evaluation experiments we show that themethodis accurate across all taxonomic ranks considered, even forsequences that originate fromnovel organisms and are as short as 1kb.Application to two metagenome datasets 15 obtained from samples ofphosphorus-removing sludge showed that the method allows the accurateclassification at genus level of most sequence fragments from thedominant populations, while at the same time correctly characterizingeven larger parts of the samples at higher taxonomic levels.

  11. Accurate location estimation of moving object In Wireless Sensor network

    Directory of Open Access Journals (Sweden)

    Vinay Bhaskar Semwal

    2011-12-01

    Full Text Available One of the central issues in wirless sensor networks is track the location, of moving object which have overhead of saving data, an accurate estimation of the target location of object with energy constraint .We do not have any mechanism which control and maintain data .The wireless communication bandwidth is also very limited. Some field which is using this technique are flood and typhoon detection, forest fire detection, temperature and humidity and ones we have these information use these information back to a central air conditioning and ventilation.In this research paper, we propose protocol based on the prediction and adaptive based algorithm which is using less sensor node reduced by an accurate estimation of the target location. We had shown that our tracking method performs well in terms of energy saving regardless of mobility pattern of the mobile target. We extends the life time of network with less sensor node. Once a new object is detected, a mobile agent will be initiated to track the roaming path of the object.

  12. An Accurate and Dynamic Computer Graphics Muscle Model

    Science.gov (United States)

    Levine, David Asher

    1997-01-01

    A computer based musculo-skeletal model was developed at the University in the departments of Mechanical and Biomedical Engineering. This model accurately represents human shoulder kinematics. The result of this model is the graphical display of bones moving through an appropriate range of motion based on inputs of EMGs and external forces. The need existed to incorporate a geometric muscle model in the larger musculo-skeletal model. Previous muscle models did not accurately represent muscle geometries, nor did they account for the kinematics of tendons. This thesis covers the creation of a new muscle model for use in the above musculo-skeletal model. This muscle model was based on anatomical data from the Visible Human Project (VHP) cadaver study. Two-dimensional digital images from the VHP were analyzed and reconstructed to recreate the three-dimensional muscle geometries. The recreated geometries were smoothed, reduced, and sliced to form data files defining the surfaces of each muscle. The muscle modeling function opened these files during run-time and recreated the muscle surface. The modeling function applied constant volume limitations to the muscle and constant geometry limitations to the tendons.

  13. Evaluation of new reference genes in papaya for accurate transcript normalization under different experimental conditions.

    Directory of Open Access Journals (Sweden)

    Xiaoyang Zhu

    Full Text Available Real-time reverse transcription PCR (RT-qPCR is a preferred method for rapid and accurate quantification of gene expression studies. Appropriate application of RT-qPCR requires accurate normalization though the use of reference genes. As no single reference gene is universally suitable for all experiments, thus reference gene(s validation under different experimental conditions is crucial for RT-qPCR analysis. To date, only a few studies on reference genes have been done in other plants but none in papaya. In the present work, we selected 21 candidate reference genes, and evaluated their expression stability in 246 papaya fruit samples using three algorithms, geNorm, NormFinder and RefFinder. The samples consisted of 13 sets collected under different experimental conditions, including various tissues, different storage temperatures, different cultivars, developmental stages, postharvest ripening, modified atmosphere packaging, 1-methylcyclopropene (1-MCP treatment, hot water treatment, biotic stress and hormone treatment. Our results demonstrated that expression stability varied greatly between reference genes and that different suitable reference gene(s or combination of reference genes for normalization should be validated according to the experimental conditions. In general, the internal reference genes EIF (Eukaryotic initiation factor 4A, TBP1 (TATA binding protein 1 and TBP2 (TATA binding protein 2 genes had a good performance under most experimental conditions, whereas the most widely present used reference genes, ACTIN (Actin 2, 18S rRNA (18S ribosomal RNA and GAPDH (Glyceraldehyde-3-phosphate dehydrogenase were not suitable in many experimental conditions. In addition, two commonly used programs, geNorm and Normfinder, were proved sufficient for the validation. This work provides the first systematic analysis for the selection of superior reference genes for accurate transcript normalization in papaya under different experimental

  14. Semiquantitative dynamic contrast-enhanced MRI for accurate classification of complex adnexal masses.

    Science.gov (United States)

    Kazerooni, Anahita Fathi; Malek, Mahrooz; Haghighatkhah, Hamidreza; Parviz, Sara; Nabil, Mahnaz; Torbati, Leila; Assili, Sanam; Saligheh Rad, Hamidreza; Gity, Masoumeh

    2017-02-01

    To identify the best dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) descriptive parameters in predicting malignancy of complex ovarian masses, and develop an optimal decision tree for accurate classification of benign and malignant complex ovarian masses. Preoperative DCE-MR images of 55 sonographically indeterminate ovarian masses (27 benign and 28 malignant) were analyzed prospectively. Four descriptive parameters of the dynamic curve, namely, time-to-peak (TTP), wash-in-rate (WIR), relative signal intensity (SI rel ), and the initial area under the curve (IAUC 60 ) were calculated on the normalized curves of specified regions-of-interest (ROIs). A two-tailed Student's t-test and two automated classifiers, linear discriminant analysis (LDA) and support vector machines (SVMs), were used to compare the performance of the mentioned parameters individually and in combination with each other. TTP (P = 6.15E-8) and WIR (P = 5.65E-5) parameters induced the highest sensitivity (89% for LDA, and 97% for SVM) and specificity (93% for LDA, and 100% for SVM), respectively. Regarding the high sensitivity of TTP and high specificity of WIR and through their combination, an accurate and simple decision-tree classifier was designed using the line equation obtained by LDA classification model. The proposed classifier achieved an accuracy of 89% and area under the ROC curve of 93%. In this study an accurate decision-tree classifier based on a combination of TTP and WIR parameters was proposed, which provides a clinically flexible framework to aid radiologists/clinicians to reach a conclusive preoperative diagnosis and patient-specific therapy plan for distinguishing malignant from benign complex ovarian masses. 2 J. Magn. Reson. Imaging 2017;45:418-427. © 2016 International Society for Magnetic Resonance in Medicine.

  15. Accurate computer simulation of a drift chamber

    International Nuclear Information System (INIS)

    Killian, T.J.

    1980-01-01

    A general purpose program for drift chamber studies is described. First the capacitance matrix is calculated using a Green's function technique. The matrix is used in a linear-least-squares fit to choose optimal operating voltages. Next the electric field is computed, and given knowledge of gas parameters and magnetic field environment, a family of electron trajectories is determined. These are finally used to make drift distance vs time curves which may be used directly by a track reconstruction program. Results are compared with data obtained from the cylindrical chamber in the Axial Field Magnet experiment at the CERN ISR

  16. Accurate computer simulation of a drift chamber

    CERN Document Server

    Killian, T J

    1980-01-01

    The author describes a general purpose program for drift chamber studies. First the capacitance matrix is calculated using a Green's function technique. The matrix is used in a linear-least-squares fit to choose optimal operating voltages. Next the electric field is computed, and given knowledge of gas parameters and magnetic field environment, a family of electron trajectories is determined. These are finally used to make drift distance vs time curves which may be used directly by a track reconstruction program. The results are compared with data obtained from the cylindrical chamber in the Axial Field Magnet experiment at the CERN ISR. (1 refs).

  17. Parente2: a fast and accurate method for detecting identity by descent

    KAUST Repository

    Rodriguez, Jesse M.

    2014-10-01

    Identity-by-descent (IBD) inference is the problem of establishing a genetic connection between two individuals through a genomic segment that is inherited by both individuals from a recent common ancestor. IBD inference is an important preceding step in a variety of population genomic studies, ranging from demographic studies to linking genomic variation with phenotype and disease. The problem of accurate IBD detection has become increasingly challenging with the availability of large collections of human genotypes and genomes: Given a cohort\\'s size, a quadratic number of pairwise genome comparisons must be performed. Therefore, computation time and the false discovery rate can also scale quadratically. To enable accurate and efficient large-scale IBD detection, we present Parente2, a novel method for detecting IBD segments. Parente2 is based on an embedded log-likelihood ratio and uses a model that accounts for linkage disequilibrium by explicitly modeling haplotype frequencies. Parente2 operates directly on genotype data without the need to phase data prior to IBD inference. We evaluate Parente2\\'s performance through extensive simulations using real data, and we show that it provides substantially higher accuracy compared to previous state-of-the-art methods while maintaining high computational efficiency.

  18. Microbiome Data Accurately Predicts the Postmortem Interval Using Random Forest Regression Models

    Directory of Open Access Journals (Sweden)

    Aeriel Belk

    2018-02-01

    Full Text Available Death investigations often include an effort to establish the postmortem interval (PMI in cases in which the time of death is uncertain. The postmortem interval can lead to the identification of the deceased and the validation of witness statements and suspect alibis. Recent research has demonstrated that microbes provide an accurate clock that starts at death and relies on ecological change in the microbial communities that normally inhabit a body and its surrounding environment. Here, we explore how to build the most robust Random Forest regression models for prediction of PMI by testing models built on different sample types (gravesoil, skin of the torso, skin of the head, gene markers (16S ribosomal RNA (rRNA, 18S rRNA, internal transcribed spacer regions (ITS, and taxonomic levels (sequence variants, species, genus, etc.. We also tested whether particular suites of indicator microbes were informative across different datasets. Generally, results indicate that the most accurate models for predicting PMI were built using gravesoil and skin data using the 16S rRNA genetic marker at the taxonomic level of phyla. Additionally, several phyla consistently contributed highly to model accuracy and may be candidate indicators of PMI.

  19. Parente2: a fast and accurate method for detecting identity by descent

    KAUST Repository

    Rodriguez, Jesse M.; Bercovici, Sivan; Huang, Lin; Frostig, Roy; Batzoglou, Serafim

    2014-01-01

    Identity-by-descent (IBD) inference is the problem of establishing a genetic connection between two individuals through a genomic segment that is inherited by both individuals from a recent common ancestor. IBD inference is an important preceding step in a variety of population genomic studies, ranging from demographic studies to linking genomic variation with phenotype and disease. The problem of accurate IBD detection has become increasingly challenging with the availability of large collections of human genotypes and genomes: Given a cohort's size, a quadratic number of pairwise genome comparisons must be performed. Therefore, computation time and the false discovery rate can also scale quadratically. To enable accurate and efficient large-scale IBD detection, we present Parente2, a novel method for detecting IBD segments. Parente2 is based on an embedded log-likelihood ratio and uses a model that accounts for linkage disequilibrium by explicitly modeling haplotype frequencies. Parente2 operates directly on genotype data without the need to phase data prior to IBD inference. We evaluate Parente2's performance through extensive simulations using real data, and we show that it provides substantially higher accuracy compared to previous state-of-the-art methods while maintaining high computational efficiency.

  20. Fast and accurate implementation of Fourier spectral approximations of nonlocal diffusion operators and its applications

    International Nuclear Information System (INIS)

    Du, Qiang; Yang, Jiang

    2017-01-01

    This work is concerned with the Fourier spectral approximation of various integral differential equations associated with some linear nonlocal diffusion and peridynamic operators under periodic boundary conditions. For radially symmetric kernels, the nonlocal operators under consideration are diagonalizable in the Fourier space so that the main computational challenge is on the accurate and fast evaluation of their eigenvalues or Fourier symbols consisting of possibly singular and highly oscillatory integrals. For a large class of fractional power-like kernels, we propose a new approach based on reformulating the Fourier symbols both as coefficients of a series expansion and solutions of some simple ODE models. We then propose a hybrid algorithm that utilizes both truncated series expansions and high order Runge–Kutta ODE solvers to provide fast evaluation of Fourier symbols in both one and higher dimensional spaces. It is shown that this hybrid algorithm is robust, efficient and accurate. As applications, we combine this hybrid spectral discretization in the spatial variables and the fourth-order exponential time differencing Runge–Kutta for temporal discretization to offer high order approximations of some nonlocal gradient dynamics including nonlocal Allen–Cahn equations, nonlocal Cahn–Hilliard equations, and nonlocal phase-field crystal models. Numerical results show the accuracy and effectiveness of the fully discrete scheme and illustrate some interesting phenomena associated with the nonlocal models.

  1. Vessel calibration for accurate material accountancy at RRP

    International Nuclear Information System (INIS)

    Yanagisawa, Yuu; Ono, Sawako; Iwamoto, Tomonori

    2004-01-01

    RRP has a 800t·Upr capacity a year to re-process, where would be handled a large amount of nuclear materials as solution. A large scale plant like RRP will require accurate materials accountancy system, so that the vessel calibration with high-precision is very important as initial vessel calibration before operation. In order to obtain the calibration curve, it is needed well-known each the increment volume related with liquid height. Then we performed at least 2 or 3 times run with water for vessel calibration and careful evaluation for the calibration data should be needed. We performed vessel calibration overall 210 vessels, and the calibration of 81 vessels including IAT and OAT were held under presence of JSGO and IAEA inspectors taking into account importance on the material accountancy. This paper describes outline of the initial vessel calibration and calibration results based on back pressure measurement with dip tubes. (author)

  2. Providing free autopoweroff plugs

    DEFF Research Database (Denmark)

    Jensen, Carsten Lynge; Hansen, Lars Gårn; Fjordbak, Troels

    2012-01-01

    Experimental evidence of the effect of providing households with cheap energy saving technology is sparse. We present results from a field experiment in which autopoweroff plugs were provided free of charge to randomly selected households. We use propensity score matching to find treatment effects...

  3. Hounsfield unit density accurately predicts ESWL success.

    Science.gov (United States)

    Magnuson, William J; Tomera, Kevin M; Lance, Raymond S

    2005-01-01

    Extracorporeal shockwave lithotripsy (ESWL) is a commonly used non-invasive treatment for urolithiasis. Helical CT scans provide much better and detailed imaging of the patient with urolithiasis including the ability to measure density of urinary stones. In this study we tested the hypothesis that density of urinary calculi as measured by CT can predict successful ESWL treatment. 198 patients were treated at Alaska Urological Associates with ESWL between January 2002 and April 2004. Of these 101 met study inclusion with accessible CT scans and stones ranging from 5-15 mm. Follow-up imaging demonstrated stone freedom in 74.2%. The overall mean Houndsfield density value for stone-free compared to residual stone groups were significantly different ( 93.61 vs 122.80 p ESWL for upper tract calculi between 5-15mm.

  4. Efficient and accurate nearest neighbor and closest pair search in high-dimensional space

    KAUST Repository

    Tao, Yufei

    2010-07-01

    Nearest Neighbor (NN) search in high-dimensional space is an important problem in many applications. From the database perspective, a good solution needs to have two properties: (i) it can be easily incorporated in a relational database, and (ii) its query cost should increase sublinearly with the dataset size, regardless of the data and query distributions. Locality-Sensitive Hashing (LSH) is a well-known methodology fulfilling both requirements, but its current implementations either incur expensive space and query cost, or abandon its theoretical guarantee on the quality of query results. Motivated by this, we improve LSH by proposing an access method called the Locality-Sensitive B-tree (LSB-tree) to enable fast, accurate, high-dimensional NN search in relational databases. The combination of several LSB-trees forms a LSB-forest that has strong quality guarantees, but improves dramatically the efficiency of the previous LSH implementation having the same guarantees. In practice, the LSB-tree itself is also an effective index which consumes linear space, supports efficient updates, and provides accurate query results. In our experiments, the LSB-tree was faster than: (i) iDistance (a famous technique for exact NN search) by two orders ofmagnitude, and (ii) MedRank (a recent approximate method with nontrivial quality guarantees) by one order of magnitude, and meanwhile returned much better results. As a second step, we extend our LSB technique to solve another classic problem, called Closest Pair (CP) search, in high-dimensional space. The long-term challenge for this problem has been to achieve subquadratic running time at very high dimensionalities, which fails most of the existing solutions. We show that, using a LSB-forest, CP search can be accomplished in (worst-case) time significantly lower than the quadratic complexity, yet still ensuring very good quality. In practice, accurate answers can be found using just two LSB-trees, thus giving a substantial

  5. Establishing Accurate and Sustainable Geospatial Reference Layers in Developing Countries

    Science.gov (United States)

    Seaman, V. Y.

    2017-12-01

    Accurate geospatial reference layers (settlement names & locations, administrative boundaries, and population) are not readily available for most developing countries. This critical information gap makes it challenging for governments to efficiently plan, allocate resources, and provide basic services. It also hampers international agencies' response to natural disasters, humanitarian crises, and other emergencies. The current work involves a recent successful effort, led by the Bill & Melinda Gates Foundation and the Government of Nigeria, to obtain such data. The data collection began in 2013, with local teams collecting names, coordinates, and administrative attributes for over 100,000 settlements using ODK-enabled smartphones. A settlement feature layer extracted from satellite imagery was used to ensure all settlements were included. Administrative boundaries (Ward, LGA) were created using the settlement attributes. These "new" boundary layers were much more accurate than existing shapefiles used by the government and international organizations. The resulting data sets helped Nigeria eradicate polio from all areas except in the extreme northeast, where security issues limited access and vaccination activities. In addition to the settlement and boundary layers, a GIS-based population model was developed, in partnership with Oak Ridge National Laboratories and Flowminder), that used the extracted settlement areas and characteristics, along with targeted microcensus data. This model provides population and demographics estimates independent of census or other administrative data, at a resolution of 90 meters. These robust geospatial data layers found many other uses, including establishing catchment area settlements and populations for health facilities, validating denominators for population-based surveys, and applications across a variety of government sectors. Based on the success of the Nigeria effort, a partnership between DfID and the Bill & Melinda Gates

  6. How Accurate Are Our Processed ENDF Cross Sections?

    International Nuclear Information System (INIS)

    Cullen, Dermott E.

    2014-05-01

    Let me start by reassuring you that currently our nuclear data processing codes are very accurate in the calculations that they perform INSIDE COMNPUTERS. However, most of them drop the ball in what should be a trivial final step to output their results into the ENDF format. This is obviously a very important step, because without accurately outputting their results we would not be able to confidently use their results in our applications. This is indeed a very important step, but unfortunately it is one that is not given the attention it deserves; hence we come to the purpose of this paper. Here I document first the state of a number of nuclear data processing codes as of February 2012, when this comparison began, and then the current state, November 2013, of the same codes. I have delayed publishing results until now to give participants time to distribute updated codes and data. The codes compared include, in alphabetical order: AMPX, NJOY, PREPRO, and SAMMY/SAMRML. During this time we have seen considerable improvement in output results, and as a direct result of this study we now have four codes that produce high precision results, but this is still a long way from ensuring that all codes that handle nuclear data are maintaining the accuracy that we require today. In the first part of this report I consider the precision of our tabulated energies; here we see obvious flaws when less-precise output is used. In the second part I consider the precision of our cross sections; here we see more subtle flaws. The important point to stress is that once these flaws are recognized it is relatively easy to eliminate them and produce high precision energies and cross sections.

  7. 'I thought they were going to handle me like a queen but they didn't': A qualitative study exploring the quality of care provided to women at the time of birth.

    Science.gov (United States)

    Lambert, Jaki; Etsane, Elsie; Bergh, Anne-Marie; Pattinson, Robert; van den Broek, Nynke

    2018-04-22

    To explore experiences of care during labour and birth from the perspectives of both the healthcare provider and women receiving care, to inform recommendations for how the quality of care can be improved and monitored, and, to identify the main aspects of care that are important to women. A descriptive phenomenological approach. 53 interviews and 10KII as per table 1 took place including in-depth interviews (IDI), focus group discussions (FGD) and key informant interviews (KII) conducted with women, healthcare providers, managers and policy makers. Following verbatim transcription thematic framework analysis was used to describe the lived experience of those interviewed. 11 public healthcare facilities providing maternity care in urban Tshwane District, Gauteng Province (n = 4) and rural Waterberg District, Limpopo Province (n = 7), South Africa. Women who had given birth in the preceding 12 weeks (49 women, 7 FGD and 23 IDI); healthcare providers working in the labour wards (33 healthcare providers; nurses, midwives, medical staff, 5 FGD, 18 IDI; managers and policy makers (10 KII). Both women and healthcare providers largely feel alone and unsupported. There is mutual distrust between women and healthcare providers exacerbated by word of mouth and the media. A lack of belief in women's ability to make appropriate choices negates principles of choice and consent. Procedure- rather than patient-centred care is prioritised by healthcare providers. Although healthcare providers know the principles of good quality care, this was not reflected in the care women described as having received. Beliefs and attitudes as well as structural and organisational problems make it difficult to provide good quality care. Caring behaviour and environment as well as companionship are the most important needs highlighted by women. Professional hierarchy is rarely seen as supportive by healthcare providers but when present, good leadership changes the culture and experience of

  8. Transmission Lines or Poles, Electric, Electric transmission lines locations provided to us from Kansas City Power and Light and City of Gardner only at this time. AIMS is working on getting other providers in area. Data is limited to CUE (Collaborative Utility Exchange) Participants and subc, Published in 2004, Johnson County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Transmission Lines or Poles, Electric dataset current as of 2004. Electric transmission lines locations provided to us from Kansas City Power and Light and City of...

  9. Accurate and precise determination of small quantity uranium by means of automatic potentiometric titration

    International Nuclear Information System (INIS)

    Liu Quanwei; Luo Zhongyan; Zhu Haiqiao; Wu Jizong

    2007-01-01

    For high radioactivity level of dissolved solution of spent fuel and the solution of uranium product, radioactive hazard must be considered and reduced as low as possible during accurate determination of uranium. In this work automatic potentiometric titration was applied and the sample only 10 mg of uranium contained was taken in order to reduce the harm of analyzer suffered from the radioactivity. RSD<0.06%, at the same time the result can be corrected for more reliable and accurate measurement. The determination method can effectively reduce the harm of analyzer suffered from the radioactivity, and meets the requirement of reliable accurate measurement of uranium. (authors)

  10. Accurate Ambient Noise Assessment Using Smartphones

    Science.gov (United States)

    Zamora, Willian; Calafate, Carlos T.; Cano, Juan-Carlos; Manzoni, Pietro

    2017-01-01

    Nowadays, smartphones have become ubiquitous and one of the main communication resources for human beings. Their widespread adoption was due to the huge technological progress and to the development of multiple useful applications. Their characteristics have also experienced a substantial improvement as they now integrate multiple sensors able to convert the smartphone into a flexible and multi-purpose sensing unit. The combined use of multiple smartphones endowed with several types of sensors gives the possibility to monitor a certain area with fine spatial and temporal granularity, a procedure typically known as crowdsensing. In this paper, we propose using smartphones as environmental noise-sensing units. For this purpose, we focus our study on the sound capture and processing procedure, analyzing the impact of different noise calculation algorithms, as well as in determining their accuracy when compared to a professional noise measurement unit. We analyze different candidate algorithms using different types of smartphones, and we study the most adequate time period and sampling strategy to optimize the data-gathering process. In addition, we perform an experimental study comparing our approach with the results obtained using a professional device. Experimental results show that, if the smartphone application is well tuned, it is possible to measure noise levels with a accuracy degree comparable to professional devices for the entire dynamic range typically supported by microphones embedded in smartphones, i.e., 35–95 dB. PMID:28430126

  11. Accurate Assessment of Computed Order Tracking

    Directory of Open Access Journals (Sweden)

    P.N. Saavedra

    2006-01-01

    Full Text Available Spectral vibration analysis using the Fourier transform is the most common technique for evaluating the mechanical condition of machinery working in stationary regimen. However, machinery operating in transient modes, such as variable speed equipment, generates spectra with distinct frequency content at each time, and the standard approach is not directly applicable for diagnostic. The "order tracking" technique is a suitable tool for analyzing variable speed machines. We have studied the computed order tracking (COT, and a new computed procedure is proposed for solving the indeterminate results generated by the traditional method at constant speed. The effect on the accuracy of the assumptions inherent in the COT was assessed using data from various simulations. The use of these simulations allowed us to determine the effect on the overall true accuracy of the method of different user-defined factors: the signal and tachometric pulse sampling frequency, the method of amplitude interpolation, and the number of tachometric pulses per revolution. Tests on real data measured on the main transmissions of a mining shovel were carried out, and we concluded that the new method is appropriate for the condition monitoring of this type of machine.

  12. Credential Service Provider (CSP)

    Data.gov (United States)

    Department of Veterans Affairs — Provides a VA operated Level 1 and Level 2 credential for individuals who require access to VA applications, yet cannot obtain a credential from another VA accepted...

  13. MAX Provider Characteristics

    Data.gov (United States)

    U.S. Department of Health & Human Services — The MAX Provider Characteristics (PC) File Implementation Report describes the design, implementation, and results of the MAXPC prototype, which was based on three...

  14. Real-Time Noise Prediction of V/STOL Aircraft in Maneuvering Flight, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal outlines a plan for enhancing and integrating new breakthrough technologies to provide accurate real-time noise prediction of V/STOL aircraft in...

  15. EQPlanar: a maximum-likelihood method for accurate organ activity estimation from whole body planar projections

    International Nuclear Information System (INIS)

    Song, N; Frey, E C; He, B; Wahl, R L

    2011-01-01

    Optimizing targeted radionuclide therapy requires patient-specific estimation of organ doses. The organ doses are estimated from quantitative nuclear medicine imaging studies, many of which involve planar whole body scans. We have previously developed the quantitative planar (QPlanar) processing method and demonstrated its ability to provide more accurate activity estimates than conventional geometric-mean-based planar (CPlanar) processing methods using physical phantom and simulation studies. The QPlanar method uses the maximum likelihood-expectation maximization algorithm, 3D organ volume of interests (VOIs), and rigorous models of physical image degrading factors to estimate organ activities. However, the QPlanar method requires alignment between the 3D organ VOIs and the 2D planar projections and assumes uniform activity distribution in each VOI. This makes application to patients challenging. As a result, in this paper we propose an extended QPlanar (EQPlanar) method that provides independent-organ rigid registration and includes multiple background regions. We have validated this method using both Monte Carlo simulation and patient data. In the simulation study, we evaluated the precision and accuracy of the method in comparison to the original QPlanar method. For the patient studies, we compared organ activity estimates at 24 h after injection with those from conventional geometric mean-based planar quantification using a 24 h post-injection quantitative SPECT reconstruction as the gold standard. We also compared the goodness of fit of the measured and estimated projections obtained from the EQPlanar method to those from the original method at four other time points where gold standard data were not available. In the simulation study, more accurate activity estimates were provided by the EQPlanar method for all the organs at all the time points compared with the QPlanar method. Based on the patient data, we concluded that the EQPlanar method provided a

  16. More accurate thermal neutron coincidence counting technique

    International Nuclear Information System (INIS)

    Baron, N.

    1978-01-01

    Using passive thermal neutron coincidence counting techniques, the accuracy of nondestructive assays of fertile material can be improved significantly using a two-ring detector. It was shown how the use of a function of the coincidence count rate ring-ratio can provide a detector response rate that is independent of variations in neutron detection efficiency caused by varying sample moderation. Furthermore, the correction for multiplication caused by SF- and (α,n)-neutrons is shown to be separable into the product of a function of the effective mass of 240 Pu (plutonium correction) and a function of the (α,n) reaction probability (matrix correction). The matrix correction is described by a function of the singles count rate ring-ratio. This correction factor is empirically observed to be identical for any combination of PuO 2 powder and matrix materials SiO 2 and MgO because of the similar relation of the (α,n)-Q value and (α,n)-reaction cross section among these matrix nuclei. However the matrix correction expression is expected to be different for matrix materials such as Na, Al, and/or Li. Nevertheless, it should be recognized that for comparison measurements among samples of similar matrix content, it is expected that some function of the singles count rate ring-ratio can be defined to account for variations in the matrix correction due to differences in the intimacy of mixture among the samples. Furthermore the magnitude of this singles count rate ring-ratio serves to identify the contaminant generating the (α,n)-neutrons. Such information is useful in process control

  17. Provider software buyer's guide.

    Science.gov (United States)

    1994-03-01

    To help long term care providers find new ways to improve quality of care and efficiency, Provider magazine presents the fourth annual listing of software firms marketing computer programs for all areas of nursing facility operations. On the following five pages, more than 80 software firms display their wares, with programs such as minimum data set and care planning, dietary, accounting and financials, case mix, and medication administration records. The guide also charts compatible hardware, integration ability, telephone numbers, company contacts, and easy-to-use reader service numbers.

  18. Accurate, fully-automated NMR spectral profiling for metabolomics.

    Directory of Open Access Journals (Sweden)

    Siamak Ravanbakhsh

    Full Text Available Many diseases cause significant changes to the concentrations of small molecules (a.k.a. metabolites that appear in a person's biofluids, which means such diseases can often be readily detected from a person's "metabolic profile"-i.e., the list of concentrations of those metabolites. This information can be extracted from a biofluids Nuclear Magnetic Resonance (NMR spectrum. However, due to its complexity, NMR spectral profiling has remained manual, resulting in slow, expensive and error-prone procedures that have hindered clinical and industrial adoption of metabolomics via NMR. This paper presents a system, BAYESIL, which can quickly, accurately, and autonomously produce a person's metabolic profile. Given a 1D 1H NMR spectrum of a complex biofluid (specifically serum or cerebrospinal fluid, BAYESIL can automatically determine the metabolic profile. This requires first performing several spectral processing steps, then matching the resulting spectrum against a reference compound library, which contains the "signatures" of each relevant metabolite. BAYESIL views spectral matching as an inference problem within a probabilistic graphical model that rapidly approximates the most probable metabolic profile. Our extensive studies on a diverse set of complex mixtures including real biological samples (serum and CSF, defined mixtures and realistic computer generated spectra; involving > 50 compounds, show that BAYESIL can autonomously find the concentration of NMR-detectable metabolites accurately (~ 90% correct identification and ~ 10% quantification error, in less than 5 minutes on a single CPU. These results demonstrate that BAYESIL is the first fully-automatic publicly-accessible system that provides quantitative NMR spectral profiling effectively-with an accuracy on these biofluids that meets or exceeds the performance of trained experts. We anticipate this tool will usher in high-throughput metabolomics and enable a wealth of new applications of

  19. An accurate solver for forward and inverse transport

    International Nuclear Information System (INIS)

    Monard, Francois; Bal, Guillaume

    2010-01-01

    This paper presents a robust and accurate way to solve steady-state linear transport (radiative transfer) equations numerically. Our main objective is to address the inverse transport problem, in which the optical parameters of a domain of interest are reconstructed from measurements performed at the domain's boundary. This inverse problem has important applications in medical and geophysical imaging, and more generally in any field involving high frequency waves or particles propagating in scattering environments. Stable solutions of the inverse transport problem require that the singularities of the measurement operator, which maps the optical parameters to the available measurements, be captured with sufficient accuracy. This in turn requires that the free propagation of particles be calculated with care, which is a difficult problem on a Cartesian grid. A standard discrete ordinates method is used for the direction of propagation of the particles. Our methodology to address spatial discretization is based on rotating the computational domain so that each direction of propagation is always aligned with one of the grid axes. Rotations are performed in the Fourier domain to achieve spectral accuracy. The numerical dispersion of the propagating particles is therefore minimal. As a result, the ballistic and single scattering components of the transport solution are calculated robustly and accurately. Physical blurring effects, such as small angular diffusion, are also incorporated into the numerical tool. Forward and inverse calculations performed in a two-dimensional setting exemplify the capabilities of the method. Although the methodology might not be the fastest way to solve transport equations, its physical accuracy provides us with a numerical tool to assess what can and cannot be reconstructed in inverse transport theory.

  20. An accurate algorithm to calculate the Hurst exponent of self-similar processes

    International Nuclear Information System (INIS)

    Fernández-Martínez, M.; Sánchez-Granero, M.A.; Trinidad Segovia, J.E.; Román-Sánchez, I.M.

    2014-01-01

    In this paper, we introduce a new approach which generalizes the GM2 algorithm (introduced in Sánchez-Granero et al. (2008) [52]) as well as fractal dimension algorithms (FD1, FD2 and FD3) (first appeared in Sánchez-Granero et al. (2012) [51]), providing an accurate algorithm to calculate the Hurst exponent of self-similar processes. We prove that this algorithm performs properly in the case of short time series when fractional Brownian motions and Lévy stable motions are considered. We conclude the paper with a dynamic study of the Hurst exponent evolution in the S and P500 index stocks. - Highlights: • We provide a new approach to properly calculate the Hurst exponent. • This generalizes FD algorithms and GM2, introduced previously by the authors. • This method (FD4) results especially appropriate for short time series. • FD4 may be used in both unifractal and multifractal contexts. • As an empirical application, we show that S and P500 stocks improved their efficiency

  1. Comparison of PIV with 4D-Flow in a physiological accurate flow phantom

    Science.gov (United States)

    Sansom, Kurt; Balu, Niranjan; Liu, Haining; Aliseda, Alberto; Yuan, Chun; Canton, Maria De Gador

    2016-11-01

    Validation of 4D MRI flow sequences with planar particle image velocimetry (PIV) is performed in a physiologically-accurate flow phantom. A patient-specific phantom of a carotid artery is connected to a pulsatile flow loop to simulate the 3D unsteady flow in the cardiovascular anatomy. Cardiac-cycle synchronized MRI provides time-resolved 3D blood velocity measurements in clinical tool that is promising but lacks a robust validation framework. PIV at three different Reynolds numbers (540, 680, and 815, chosen based on +/- 20 % of the average velocity from the patient-specific CCA waveform) and four different Womersley numbers (3.30, 3.68, 4.03, and 4.35, chosen to reflect a physiological range of heart rates) are compared to 4D-MRI measurements. An accuracy assessment of raw velocity measurements and a comparison of estimated and measureable flow parameters such as wall shear stress, fluctuating velocity rms, and Lagrangian particle residence time, will be presented, with justification for their biomechanics relevance to the pathophysiology of arterial disease: atherosclerosis and intimal hyperplasia. Lastly, the framework is applied to a new 4D-Flow MRI sequence and post processing techniques to provide a quantitative assessment with the benchmarked data. Department of Education GAANN Fellowship.

  2. An accurate algorithm to calculate the Hurst exponent of self-similar processes

    Energy Technology Data Exchange (ETDEWEB)

    Fernández-Martínez, M., E-mail: fmm124@ual.es [Department of Mathematics, Faculty of Science, Universidad de Almería, 04120 Almería (Spain); Sánchez-Granero, M.A., E-mail: misanche@ual.es [Department of Mathematics, Faculty of Science, Universidad de Almería, 04120 Almería (Spain); Trinidad Segovia, J.E., E-mail: jetrini@ual.es [Department of Accounting and Finance, Faculty of Economics and Business, Universidad de Almería, 04120 Almería (Spain); Román-Sánchez, I.M., E-mail: iroman@ual.es [Department of Accounting and Finance, Faculty of Economics and Business, Universidad de Almería, 04120 Almería (Spain)

    2014-06-27

    In this paper, we introduce a new approach which generalizes the GM2 algorithm (introduced in Sánchez-Granero et al. (2008) [52]) as well as fractal dimension algorithms (FD1, FD2 and FD3) (first appeared in Sánchez-Granero et al. (2012) [51]), providing an accurate algorithm to calculate the Hurst exponent of self-similar processes. We prove that this algorithm performs properly in the case of short time series when fractional Brownian motions and Lévy stable motions are considered. We conclude the paper with a dynamic study of the Hurst exponent evolution in the S and P500 index stocks. - Highlights: • We provide a new approach to properly calculate the Hurst exponent. • This generalizes FD algorithms and GM2, introduced previously by the authors. • This method (FD4) results especially appropriate for short time series. • FD4 may be used in both unifractal and multifractal contexts. • As an empirical application, we show that S and P500 stocks improved their efficiency.

  3. What HERA may provide?

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hannes [DESY, Hamburg (Germany); De Roeck, Albert [CERN, Genf (Switzerland); Bartles, Jochen [Univ. Hamburg (DE). Institut fuer Theoretische Physik II] (and others)

    2008-09-15

    More than 100 people participated in a discussion session at the DIS08 workshop on the topic What HERA may provide. A summary of the discussion with a structured outlook and list of desirable measurements and theory calculations is given. (orig.)

  4. What HERA may provide?

    International Nuclear Information System (INIS)

    Jung, Hannes; De Roeck, Albert; Bartles, Jochen

    2008-09-01

    More than 100 people participated in a discussion session at the DIS08 workshop on the topic What HERA may provide. A summary of the discussion with a structured outlook and list of desirable measurements and theory calculations is given. (orig.)

  5. Provider of Services File

    Data.gov (United States)

    U.S. Department of Health & Human Services — The POS file consists of two data files, one for CLIA labs and one for 18 other provider types. The file names are CLIA and OTHER. If downloading the file, note it...

  6. LSM Proteins Provide Accurate Splicing and Decay of Selected Transcripts to Ensure Normal Arabidopsis Development[W

    Science.gov (United States)

    Perea-Resa, Carlos; Hernández-Verdeja, Tamara; López-Cobollo, Rosa; Castellano, María del Mar; Salinas, Julio

    2012-01-01

    In yeast and animals, SM-like (LSM) proteins typically exist as heptameric complexes and are involved in different aspects of RNA metabolism. Eight LSM proteins, LSM1 to 8, are highly conserved and form two distinct heteroheptameric complexes, LSM1-7 and LSM2-8,that function in mRNA decay and splicing, respectively. A search of the Arabidopsis thaliana genome identifies 11 genes encoding proteins related to the eight conserved LSMs, the genes encoding the putative LSM1, LSM3, and LSM6 proteins being duplicated. Here, we report the molecular and functional characterization of the Arabidopsis LSM gene family. Our results show that the 11 LSM genes are active and encode proteins that are also organized in two different heptameric complexes. The LSM1-7 complex is cytoplasmic and is involved in P-body formation and mRNA decay by promoting decapping. The LSM2-8 complex is nuclear and is required for precursor mRNA splicing through U6 small nuclear RNA stabilization. More importantly, our results also reveal that these complexes are essential for the correct turnover and splicing of selected development-related mRNAs and for the normal development of Arabidopsis. We propose that LSMs play a critical role in Arabidopsis development by ensuring the appropriate development-related gene expression through the regulation of mRNA splicing and decay. PMID:23221597

  7. Accurate calculation of field and carrier distributions in doped semiconductors

    Directory of Open Access Journals (Sweden)

    Wenji Yang

    2012-06-01

    Full Text Available We use the numerical squeezing algorithm(NSA combined with the shooting method to accurately calculate the built-in fields and carrier distributions in doped silicon films (SFs in the micron and sub-micron thickness range and results are presented in graphical form for variety of doping profiles under different boundary conditions. As a complementary approach, we also present the methods and the results of the inverse problem (IVP - finding out the doping profile in the SFs for given field distribution. The solution of the IVP provides us the approach to arbitrarily design field distribution in SFs - which is very important for low dimensional (LD systems and device designing. Further more, the solution of the IVP is both direct and much easy for all the one-, two-, and three-dimensional semiconductor systems. With current efforts focused on the LD physics, knowing of the field and carrier distribution details in the LD systems will facilitate further researches on other aspects and hence the current work provides a platform for those researches.

  8. Building Service Provider Capabilities

    DEFF Research Database (Denmark)

    Brandl, Kristin; Jaura, Manya; Ørberg Jensen, Peter D.

    2015-01-01

    In this paper we study whether and how the interaction between clients and the service providers contributes to the development of capabilities in service provider firms. In situations where such a contribution occurs, we analyze how different types of activities in the production process...... process. We find that clients influence the development of human capital capabilities and management capabilities in reciprocally produced services. While in sequential produced services clients influence the development of organizational capital capabilities and management capital capabilities....... of the services, such as sequential or reciprocal task activities, influence the development of different types of capabilities. We study five cases of offshore-outsourced knowledge-intensive business services that are distinguished according to their reciprocal or sequential task activities in their production...

  9. Providing x-rays

    International Nuclear Information System (INIS)

    Mallozzi, P.J.; Epstein, H.M.

    1985-01-01

    This invention provides an apparatus for providing x-rays to an object that may be in an ordinary environment such as air at approximately atmospheric pressure. The apparatus comprises: means (typically a laser beam) for directing energy onto a target to produce x-rays of a selected spectrum and intensity at the target; a fluid-tight enclosure around the target; means for maintaining the pressure in the first enclosure substantially below atmospheric pressure; a fluid-tight second enclosure adjoining the first enclosure, the common wall portion having an opening large enough to permit x-rays to pass through but small enough to allow the pressure reducing means to evacuate gas from the first enclosure at least as fast as it enters through the opening; the second enclosure filled with a gas that is highly transparent to x-rays; the wall of the second enclosure to which the x-rays travel having a portion that is highly transparent to x-rays (usually a beryllium or plastic foil), so that the object to which the x-rays are to be provided may be located outside the second enclosure and adjacent thereto and thus receive the x-rays substantially unimpeded by air or other intervening matter. The apparatus is particularly suited to obtaining EXAFS (extended x-ray fine structure spectroscopy) data on a material

  10. Why healthcare providers merge.

    Science.gov (United States)

    Postma, Jeroen; Roos, Anne-Fleur

    2016-04-01

    In many OECD countries, healthcare sectors have become increasingly concentrated as a result of mergers. However, detailed empirical insight into why healthcare providers merge is lacking. Also, we know little about the influence of national healthcare policies on mergers. We fill this gap in the literature by conducting a survey study on mergers among 848 Dutch healthcare executives, of which 35% responded (resulting in a study sample of 239 executives). A total of 65% of the respondents was involved in at least one merger between 2005 and 2012. During this period, Dutch healthcare providers faced a number of policy changes, including increasing competition, more pressure from purchasers, growing financial risks, de-institutionalisation of long-term care and decentralisation of healthcare services to municipalities. Our empirical study shows that healthcare providers predominantly merge to improve the provision of healthcare services and to strengthen their market position. Also efficiency and financial reasons are important drivers of merger activity in healthcare. We find that motives for merger are related to changes in health policies, in particular to the increasing pressure from competitors, insurers and municipalities.

  11. PROVIDING WOMEN, KEPT MEN

    Science.gov (United States)

    Mojola, Sanyu A

    2014-01-01

    This paper draws on ethnographic and interview based fieldwork to explore accounts of intimate relationships between widowed women and poor young men that emerged in the wake of economic crisis and a devastating HIV epidemic among the Luo ethnic group in Western Kenya. I show how the cooptation of widow inheritance practices in the wake of an overwhelming number of widows as well as economic crisis resulted in widows becoming providing women and poor young men becoming kept men. I illustrate how widows in this setting, by performing a set of practices central to what it meant to be a man in this society – pursuing and providing for their partners - were effectively doing masculinity. I will also show how young men, rather than being feminized by being kept, deployed other sets of practices to prove their masculinity and live in a manner congruent with cultural ideals. I argue that ultimately, women’s practice of masculinity in large part seemed to serve patriarchal ends. It not only facilitated the fulfillment of patriarchal expectations of femininity – to being inherited – but also served, in the end, to provide a material base for young men’s deployment of legitimizing and culturally valued sets of masculine practice. PMID:25489121

  12. Self-Expression on Social Media: Do Tweets Present Accurate and Positive Portraits of Impulsivity, Self-Esteem, and Attachment Style?

    Science.gov (United States)

    Orehek, Edward; Human, Lauren J

    2017-01-01

    Self-expression values are at an all-time high, and people are increasingly relying upon social media platforms to express themselves positively and accurately. We examined whether self-expression on the social media platform Twitter elicits positive and accurate social perceptions. Eleven perceivers rated 128 individuals (targets; total dyadic impressions = 1,408) on their impulsivity, self-esteem, and attachment style, based solely on the information provided in targets' 10 most recent tweets. Targets were on average perceived normatively and with distinctive self-other agreement, indicating both positive and accurate social perceptions. There were also individual differences in how positively and accurately targets were perceived, which exploratory analyses indicated may be partially driven by differential word usage, such as the use of positive emotion words and self- versus other-focus. This study demonstrates that self-expression on social media can elicit both positive and accurate perceptions and begins to shed light on how to curate such perceptions.

  13. GPS Precision Timing at CERN

    CERN Document Server

    Beetham, C G

    1999-01-01

    For the past decade, the Global Positioning System (GPS) has been used to provide precise time, frequency and position co-ordinates world-wide. Recently, equipment has become available specialising in providing extremely accurate timing information, referenced to Universal Time Co-ordinates (UTC). This feature has been used at CERN to provide time of day information for systems that have been installed in the Proton Synchrotron (PS), Super Proton Synchrotron (SPS) and the Large Electron Positron (LEP) machines. The different systems are described as well as the planned developments, particularly with respect to optical transmission and the Inter-Range Instrumentation Group IRIG-B standard, for future use in the Large Hadron Collider (LHC).

  14. Numerical solution of the state-delayed optimal control problems by a fast and accurate finite difference θ-method

    Science.gov (United States)

    Hajipour, Mojtaba; Jajarmi, Amin

    2018-02-01

    Using the Pontryagin's maximum principle for a time-delayed optimal control problem results in a system of coupled two-point boundary-value problems (BVPs) involving both time-advance and time-delay arguments. The analytical solution of this advance-delay two-point BVP is extremely difficult, if not impossible. This paper provides a discrete general form of the numerical solution for the derived advance-delay system by applying a finite difference θ-method. This method is also implemented for the infinite-time horizon time-delayed optimal control problems by using a piecewise version of the θ-method. A matrix formulation and the error analysis of the suggested technique are provided. The new scheme is accurate, fast and very effective for the optimal control of linear and nonlinear time-delay systems. Various types of finite- and infinite-time horizon problems are included to demonstrate the accuracy, validity and applicability of the new technique.

  15. Electronic remote blood issue: a combination of remote blood issue with a system for end-to-end electronic control of transfusion to provide a "total solution" for a safe and timely hospital blood transfusion service.

    Science.gov (United States)

    Staves, Julie; Davies, Amanda; Kay, Jonathan; Pearson, Oliver; Johnson, Tony; Murphy, Michael F

    2008-03-01

    The rapid provision of red cell (RBC) units to patients needing blood urgently is an issue of major importance in transfusion medicine. The development of electronic issue (sometimes termed "electronic crossmatch") has facilitated rapid provision of RBC units by avoidance of the serologic crossmatch in eligible patients. A further development is the issue of blood under electronic control at blood refrigerator remote from the blood bank. This study evaluated a system for electronic remote blood issue (ERBI) developed as an enhancement of a system for end-to-end electronic control of hospital transfusion. Practice was evaluated before and after its introduction in cardiac surgery. Before the implementation of ERBI, the median time to deliver urgently required RBC units to the patient was 24 minutes. After its implementation, RBC units were obtained from the nearby blood refrigerator in a median time of 59 seconds (range, 30 sec to 2 min). The study also found that unused requests were reduced significantly from 42 to 20 percent, the number of RBC units issued reduced by 52 percent, the number of issued units that were transfused increased from 40 to 62 percent, and there was a significant reduction in the workload of both blood bank and clinical staff. This study evaluated a combination of remote blood issue with an end-to-end electronically controlled hospital transfusion process, ERBI. ERBI reduced the time to make blood available for surgical patients and improved the efficiency of hospital transfusion.

  16. Accurate and noninvasive embryos screening during in vitro fertilization (IVF) assisted by Raman analysis of embryos culture medium Accurate and noninvasive embryos screening during IVF

    Science.gov (United States)

    Shen, A. G.; Peng, J.; Zhao, Q. H.; Su, L.; Wang, X. H.; Hu, J. M.; Yang, J.

    2012-04-01

    In combination with morphological evaluation tests, we employ Raman spectroscopy to select higher potential reproductive embryos during in vitro fertilization (IVF) based on chemical composition of embryos culture medium. In this study, 57 Raman spectra are acquired from both higher and lower quality embryos culture medium (ECM) from 10 patients which have been preliminarily confirmed by clinical assay. Data are fit by using a linear combination model of least squares method in which 12 basis spectra represent the chemical features of ECM. The final fitting coefficients provide insight into the chemical compositions of culture medium samples and are subsequently used as criterion to evaluate the quality of embryos. The relative fitting coefficients ratios of sodium pyruvate/albumin and phenylalanine/albumin seem act as key roles in the embryo screening, attaining 85.7% accuracy in comparison with clinical pregnancy. The good results demonstrate that Raman spectroscopy therefore is an important candidate for an accurate and noninvasive screening of higher quality embryos, which potentially decrease the time-consuming clinical trials during IVF.

  17. Providing Compassion through Flow

    Directory of Open Access Journals (Sweden)

    Lydia Royeen

    2015-07-01

    Full Text Available Meg Kral, MS, OTR/L, CLT, is the cover artist for the Summer 2015 issue of The Open Journal of Occupational Therapy. Her untitled piece of art is an oil painting and is a re-creation of a photograph taken while on vacation. Meg is currently supervisor of outpatient services at Rush University Medical Center. She is lymphedema certified and has a specific interest in breast cancer lymphedema. Art and occupational therapy serve similar purposes for Meg: both provide a sense of flow. She values the outcomes, whether it is a piece of art or improved functional status

  18. Rapid and accurate pyrosequencing of angiosperm plastid genomes

    Science.gov (United States)

    Moore, Michael J; Dhingra, Amit; Soltis, Pamela S; Shaw, Regina; Farmerie, William G; Folta, Kevin M; Soltis, Douglas E

    2006-01-01

    Background Plastid genome sequence information is vital to several disciplines in plant biology, including phylogenetics and molecular biology. The past five years have witnessed a dramatic increase in the number of completely sequenced plastid genomes, fuelled largely by advances in conventional Sanger sequencing technology. Here we report a further significant reduction in time and cost for plastid genome sequencing through the successful use of a newly available pyrosequencing platform, the Genome Sequencer 20 (GS 20) System (454 Life Sciences Corporation), to rapidly and accurately sequence the whole plastid genomes of the basal eudicot angiosperms Nandina domestica (Berberidaceae) and Platanus occidentalis (Platanaceae). Results More than 99.75% of each plastid genome was simultaneously obtained during two GS 20 sequence runs, to an average depth of coverage of 24.6× in Nandina and 17.3× in Platanus. The Nandina and Platanus plastid genomes shared essentially identical gene complements and possessed the typical angiosperm plastid structure and gene arrangement. To assess the accuracy of the GS 20 sequence, over 45 kilobases of sequence were generated for each genome using conventional sequencing. Overall error rates of 0.043% and 0.031% were observed in GS 20 sequence for Nandina and Platanus, respectively. More than 97% of all observed errors were associated with homopolymer runs, with ~60% of all errors associated with homopolymer runs of 5 or more nucleotides and ~50% of all errors associated with regions of extensive homopolymer runs. No substitution errors were present in either genome. Error rates were generally higher in the single-copy and noncoding regions of both plastid genomes relative to the inverted repeat and coding regions. Conclusion Highly accurate and essentially complete sequence information was obtained for the Nandina and Platanus plastid genomes using the GS 20 System. More importantly, the high accuracy observed in the GS 20 plastid

  19. Rapid and accurate pyrosequencing of angiosperm plastid genomes

    Directory of Open Access Journals (Sweden)

    Farmerie William G

    2006-08-01

    Full Text Available Abstract Background Plastid genome sequence information is vital to several disciplines in plant biology, including phylogenetics and molecular biology. The past five years have witnessed a dramatic increase in the number of completely sequenced plastid genomes, fuelled largely by advances in conventional Sanger sequencing technology. Here we report a further significant reduction in time and cost for plastid genome sequencing through the successful use of a newly available pyrosequencing platform, the Genome Sequencer 20 (GS 20 System (454 Life Sciences Corporation, to rapidly and accurately sequence the whole plastid genomes of the basal eudicot angiosperms Nandina domestica (Berberidaceae and Platanus occidentalis (Platanaceae. Results More than 99.75% of each plastid genome was simultaneously obtained during two GS 20 sequence runs, to an average depth of coverage of 24.6× in Nandina and 17.3× in Platanus. The Nandina and Platanus plastid genomes shared essentially identical gene complements and possessed the typical angiosperm plastid structure and gene arrangement. To assess the accuracy of the GS 20 sequence, over 45 kilobases of sequence were generated for each genome using conventional sequencing. Overall error rates of 0.043% and 0.031% were observed in GS 20 sequence for Nandina and Platanus, respectively. More than 97% of all observed errors were associated with homopolymer runs, with ~60% of all errors associated with homopolymer runs of 5 or more nucleotides and ~50% of all errors associated with regions of extensive homopolymer runs. No substitution errors were present in either genome. Error rates were generally higher in the single-copy and noncoding regions of both plastid genomes relative to the inverted repeat and coding regions. Conclusion Highly accurate and essentially complete sequence information was obtained for the Nandina and Platanus plastid genomes using the GS 20 System. More importantly, the high accuracy

  20. Accurate characterisation of post moulding shrinkage of polymer parts

    DEFF Research Database (Denmark)

    Neves, L. C.; De Chiffre, L.; González-Madruga, D.

    2015-01-01

    The work deals with experimental determination of the shrinkage of polymer parts after injection moulding. A fixture for length measurements on 8 parts at the same time was designed and manufactured in Invar, mounted with 8 electronic gauges, and provided with 3 temperature sensors. The fixture w...

  1. Thermally-aware composite run-time CPU power models

    OpenAIRE

    Walker, Matthew J.; Diestelhorst, Stephan; Hansson, Andreas; Balsamo, Domenico; Merrett, Geoff V.; Al-Hashimi, Bashir M.

    2016-01-01

    Accurate and stable CPU power modelling is fundamental in modern system-on-chips (SoCs) for two main reasons: 1) they enable significant online energy savings by providing a run-time manager with reliable power consumption data for controlling CPU energy-saving techniques; 2) they can be used as accurate and trusted reference models for system design and exploration. We begin by showing the limitations in typical performance monitoring counter (PMC) based power modelling approaches and illust...

  2. 76 FR 36996 - Extension of Time for Filing Returns

    Science.gov (United States)

    2011-06-24

    ... less time to complete accurate income tax returns and to provide timely information to the trust's... either chapter 7 or chapter 11 of Title 11 of the U.S. Code that is required to file an income tax return... estate or trust income tax return or failure to pay the amount shown as tax on the return. (g) Effective...

  3. Accurate formulas for the penalty caused by interferometric crosstalk

    DEFF Research Database (Denmark)

    Rasmussen, Christian Jørgen; Liu, Fenghai; Jeppesen, Palle

    2000-01-01

    New simple formulas for the penalty caused by interferometric crosstalk in PIN receiver systems and optically preamplified receiver systems are presented. They are more accurate than existing formulas.......New simple formulas for the penalty caused by interferometric crosstalk in PIN receiver systems and optically preamplified receiver systems are presented. They are more accurate than existing formulas....

  4. A new, accurate predictive model for incident hypertension

    DEFF Research Database (Denmark)

    Völzke, Henry; Fung, Glenn; Ittermann, Till

    2013-01-01

    Data mining represents an alternative approach to identify new predictors of multifactorial diseases. This work aimed at building an accurate predictive model for incident hypertension using data mining procedures.......Data mining represents an alternative approach to identify new predictors of multifactorial diseases. This work aimed at building an accurate predictive model for incident hypertension using data mining procedures....

  5. Accurate and Simple Calibration of DLP Projector Systems

    DEFF Research Database (Denmark)

    Wilm, Jakob; Olesen, Oline Vinter; Larsen, Rasmus

    2014-01-01

    does not rely on an initial camera calibration, and so does not carry over the error into projector calibration. A radial interpolation scheme is used to convert features coordinates into projector space, thereby allowing for a very accurate procedure. This allows for highly accurate determination...

  6. Accurate Compton scattering measurements for N{sub 2} molecules

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Kohjiro [Advanced Technology Research Center, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515 (Japan); Itou, Masayoshi; Tsuji, Naruki; Sakurai, Yoshiharu [Japan Synchrotron Radiation Research Institute (JASRI), 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Hosoya, Tetsuo; Sakurai, Hiroshi, E-mail: sakuraih@gunma-u.ac.jp [Department of Production Science and Technology, Gunma University, 29-1 Hon-cho, Ota, Gunma 373-0057 (Japan)

    2011-06-14

    The accurate Compton profiles of N{sub 2} gas were measured using 121.7 keV synchrotron x-rays. The present accurate measurement proves the better agreement of the CI (configuration interaction) calculation than the Hartree-Fock calculation and suggests the importance of multi-excitation in the CI calculations for the accuracy of wavefunctions in ground states.

  7. Fast and accurate calculation of the properties of water and steam for simulation

    International Nuclear Information System (INIS)

    Szegi, Zs.; Gacs, A.

    1990-01-01

    A basic principle simulator was developed at the CRIP, Budapest, for real time simulation of the transients of WWER-440 type nuclear power plants. Its integral part is the fast and accurate calculation of the thermodynamic properties of water and steam. To eliminate successive approximations, the model system of the secondary coolant circuit requires binary forms which are known as inverse functions, countinuous when crossing the saturation line, accurate and coherent for all argument combinations. A solution which reduces the computer memory and execution time demand is reported. (author) 36 refs.; 5 figs.; 3 tabs

  8. Providing rehabilitation online

    DEFF Research Database (Denmark)

    Bødker, Malene; Juul, Annegrete

    2015-01-01

    Purpose – Telecare promises to deliver healthcare services more efficiently while, at the same time, improving the quality of care. The purpose of this paper is to challenge these promises by analysing the implications of introducing telecare in the rehabilitation of patients suffering from chronic...... obstructive pulmonary disease. Design/methodology/approach – Empirically, the paper is based on interviews with and observations of rehabilitation therapists and patients taking part in a Danish telerehabilitation programme. Theoretically, the paper draws on Science and Technology Studies. Findings...... one ends. Practical implications – Evaluations of telecare technologies should pay more attention to workand responsibility-related effects of introducing telecare in order better to account for predicted and unpredicted as well as desirable and undesirable socio-technical changes. Originality/value...

  9. Providing NHS staff with height-adjustable workstations and behaviour change strategies to reduce workplace sitting time: protocol for the Stand More AT (SMArT) Work cluster randomised controlled trial.

    Science.gov (United States)

    O'Connell, S E; Jackson, B R; Edwardson, C L; Yates, T; Biddle, S J H; Davies, M J; Dunstan, D; Esliger, D; Gray, L; Miller, P; Munir, F

    2015-12-09

    High levels of sedentary behaviour (i.e., sitting) are a risk factor for poor health. With high levels of sitting widespread in desk-based office workers, office workplaces are an appropriate setting for interventions aimed at reducing sedentary behaviour. This paper describes the development processes and proposed intervention procedures of Stand More AT (SMArT) Work, a multi-component randomised control (RCT) trial which aims to reduce occupational sitting time in desk-based office workers within the National Health Service (NHS). SMArT Work consists of 2 phases: 1) intervention development: The development of the SMArT Work intervention takes a community-based participatory research approach using the Behaviour Change Wheel. Focus groups will collect detailed information to gain a better understanding of the most appropriate strategies, to sit alongside the provision of height-adjustable workstations, at the environmental, organisational and individual level that support less occupational sitting. 2) intervention delivery and evaluation: The 12 month cluster RCT aims to reduce workplace sitting in the University Hospitals of Leicester NHS Trust. Desk-based office workers (n = 238) will be randomised to control or intervention clusters, with the intervention group receiving height-adjustable workstations and supporting techniques based on the feedback received from the development phase. Data will be collected at four time points; baseline, 3, 6 and 12 months. The primary outcome is a reduction in sitting time, measured by the activPAL(TM) micro at 12 months. Secondary outcomes include objectively measured physical activity and a variety of work-related health and psycho-social measures. A process evaluation will also take place. This study will be the first long-term, evidence-based, multi-component cluster RCT aimed at reducing occupational sitting within the NHS. This study will help form a better understanding and knowledge base of facilitators and

  10. Accurate reconstruction of hyperspectral images from compressive sensing measurements

    Science.gov (United States)

    Greer, John B.; Flake, J. C.

    2013-05-01

    The emerging field of Compressive Sensing (CS) provides a new way to capture data by shifting the heaviest burden of data collection from the sensor to the computer on the user-end. This new means of sensing requires fewer measurements for a given amount of information than traditional sensors. We investigate the efficacy of CS for capturing HyperSpectral Imagery (HSI) remotely. We also introduce a new family of algorithms for constructing HSI from CS measurements with Split Bregman Iteration [Goldstein and Osher,2009]. These algorithms combine spatial Total Variation (TV) with smoothing in the spectral dimension. We examine models for three different CS sensors: the Coded Aperture Snapshot Spectral Imager-Single Disperser (CASSI-SD) [Wagadarikar et al.,2008] and Dual Disperser (CASSI-DD) [Gehm et al.,2007] cameras, and a hypothetical random sensing model closer to CS theory, but not necessarily implementable with existing technology. We simulate the capture of remotely sensed images by applying the sensor forward models to well-known HSI scenes - an AVIRIS image of Cuprite, Nevada and the HYMAP Urban image. To measure accuracy of the CS models, we compare the scenes constructed with our new algorithm to the original AVIRIS and HYMAP cubes. The results demonstrate the possibility of accurately sensing HSI remotely with significantly fewer measurements than standard hyperspectral cameras.

  11. Accurate measurement of RF exposure from emerging wireless communication systems

    International Nuclear Information System (INIS)

    Letertre, Thierry; Toffano, Zeno; Monebhurrun, Vikass

    2013-01-01

    Isotropic broadband probes or spectrum analyzers (SAs) may be used for the measurement of rapidly varying electromagnetic fields generated by emerging wireless communication systems. In this paper this problematic is investigated by comparing the responses measured by two different isotropic broadband probes typically used to perform electric field (E-field) evaluations. The broadband probes are submitted to signals with variable duty cycles (DC) and crest factors (CF) either with or without Orthogonal Frequency Division Multiplexing (OFDM) modulation but with the same root-mean-square (RMS) power. The two probes do not provide accurate enough results for deterministic signals such as Worldwide Interoperability for Microwave Access (WIMAX) or Long Term Evolution (LTE) as well as for non-deterministic signals such as Wireless Fidelity (WiFi). The legacy measurement protocols should be adapted to cope for the emerging wireless communication technologies based on the OFDM modulation scheme. This is not easily achieved except when the statistics of the RF emission are well known. In this case the measurement errors are shown to be systematic and a correction factor or calibration can be applied to obtain a good approximation of the total RMS power.

  12. HIPPI: highly accurate protein family classification with ensembles of HMMs

    Directory of Open Access Journals (Sweden)

    Nam-phuong Nguyen

    2016-11-01

    Full Text Available Abstract Background Given a new biological sequence, detecting membership in a known family is a basic step in many bioinformatics analyses, with applications to protein structure and function prediction and metagenomic taxon identification and abundance profiling, among others. Yet family identification of sequences that are distantly related to sequences in public databases or that are fragmentary remains one of the more difficult analytical problems in bioinformatics. Results We present a new technique for family identification called HIPPI (Hierarchical Profile Hidden Markov Models for Protein family Identification. HIPPI uses a novel technique to represent a multiple sequence alignment for a given protein family or superfamily by an ensemble of profile hidden Markov models computed using HMMER. An evaluation of HIPPI on the Pfam database shows that HIPPI has better overall precision and recall than blastp, HMMER, and pipelines based on HHsearch, and maintains good accuracy even for fragmentary query sequences and for protein families with low average pairwise sequence identity, both conditions where other methods degrade in accuracy. Conclusion HIPPI provides accurate protein family identification and is robust to difficult model conditions. Our results, combined with observations from previous studies, show that ensembles of profile Hidden Markov models can better represent multiple sequence alignments than a single profile Hidden Markov model, and thus can improve downstream analyses for various bioinformatic tasks. Further research is needed to determine the best practices for building the ensemble of profile Hidden Markov models. HIPPI is available on GitHub at https://github.com/smirarab/sepp .

  13. Can numerical simulations accurately predict hydrodynamic instabilities in liquid films?

    Science.gov (United States)

    Denner, Fabian; Charogiannis, Alexandros; Pradas, Marc; van Wachem, Berend G. M.; Markides, Christos N.; Kalliadasis, Serafim

    2014-11-01

    Understanding the dynamics of hydrodynamic instabilities in liquid film flows is an active field of research in fluid dynamics and non-linear science in general. Numerical simulations offer a powerful tool to study hydrodynamic instabilities in film flows and can provide deep insights into the underlying physical phenomena. However, the direct comparison of numerical results and experimental results is often hampered by several reasons. For instance, in numerical simulations the interface representation is problematic and the governing equations and boundary conditions may be oversimplified, whereas in experiments it is often difficult to extract accurate information on the fluid and its behavior, e.g. determine the fluid properties when the liquid contains particles for PIV measurements. In this contribution we present the latest results of our on-going, extensive study on hydrodynamic instabilities in liquid film flows, which includes direct numerical simulations, low-dimensional modelling as well as experiments. The major focus is on wave regimes, wave height and wave celerity as a function of Reynolds number and forcing frequency of a falling liquid film. Specific attention is paid to the differences in numerical and experimental results and the reasons for these differences. The authors are grateful to the EPSRC for their financial support (Grant EP/K008595/1).

  14. Development of fast and accurate Monte Carlo code MVP

    International Nuclear Information System (INIS)

    Mori, Takamasa

    2001-01-01

    The development work of fast and accurate Monte Carlo code MVP has started at JAERI in late 80s. From the beginning, the code was designed to utilize vector supercomputers and achieved higher computation speed by a factor of 10 or more compared with conventional codes. In 1994, the first version of MVP was released together with cross section libraries based on JENDL-3.1 and JENDL-3.2. In 1996, minor revision was made by adding several functions such as treatments of ENDF-B6 file 6 data, time dependent problem, and so on. Since 1996, several works have been carried out for the next version of MVP. The main works are (1) the development of continuous energy Monte Carlo burn-up calculation code MVP-BURN, (2) the development of a system to generate cross section libraries at arbitrary temperature, and (3) the study on error estimations and their biases in Monte Carlo eigenvalue calculations. This paper summarizes the main features of MVP, results of recent studies and future plans for MVP. (author)

  15. Podiatry Ankle Duplex Scan: Readily Learned and Accurate in Diabetes.

    Science.gov (United States)

    Normahani, Pasha; Powezka, Katarzyna; Aslam, Mohammed; Standfield, Nigel J; Jaffer, Usman

    2018-03-01

    We aimed to train podiatrists to perform a focused duplex ultrasound scan (DUS) of the tibial vessels at the ankle in diabetic patients; podiatry ankle (PodAnk) duplex scan. Thirteen podiatrists underwent an intensive 3-hour long simulation training session. Participants were then assessed performing bilateral PodAnk duplex scans of 3 diabetic patients with peripheral arterial disease. Participants were assessed using the duplex ultrasound objective structured assessment of technical skills (DUOSATS) tool and an "Imaging Score". A total of 156 vessel assessments were performed. All patients had abnormal waveforms with a loss of triphasic flow. Loss of triphasic flow was accurately detected in 145 (92.9%) vessels; the correct waveform was identified in 139 (89.1%) cases. Participants achieved excellent DUOSATS scores (median 24 [interquartile range: 23-25], max attainable score of 26) as well as "Imaging Scores" (8 [8-8], max attainable score of 8) indicating proficiency in technical skills. The mean time taken for each bilateral ankle assessment was 20.4 minutes (standard deviation ±6.7). We have demonstrated that a focused DUS for the purpose of vascular assessment of the diabetic foot is readily learned using intensive simulation training.

  16. Accurate Prediction of Motor Failures by Application of Multi CBM Tools: A Case Study

    Science.gov (United States)

    Dutta, Rana; Singh, Veerendra Pratap; Dwivedi, Jai Prakash

    2018-02-01

    Motor failures are very difficult to predict accurately with a single condition-monitoring tool as both electrical and the mechanical systems are closely related. Electrical problem, like phase unbalance, stator winding insulation failures can, at times, lead to vibration problem and at the same time mechanical failures like bearing failure, leads to rotor eccentricity. In this case study of a 550 kW blower motor it has been shown that a rotor bar crack was detected by current signature analysis and vibration monitoring confirmed the same. In later months in a similar motor vibration monitoring predicted bearing failure and current signature analysis confirmed the same. In both the cases, after dismantling the motor, the predictions were found to be accurate. In this paper we will be discussing the accurate predictions of motor failures through use of multi condition monitoring tools with two case studies.

  17. A spectroscopic transfer standard for accurate atmospheric CO measurements

    Science.gov (United States)

    Nwaboh, Javis A.; Li, Gang; Serdyukov, Anton; Werhahn, Olav; Ebert, Volker

    2016-04-01

    Atmospheric carbon monoxide (CO) is a precursor of essential climate variables and has an indirect effect for enhancing global warming. Accurate and reliable measurements of atmospheric CO concentration are becoming indispensable. WMO-GAW reports states a compatibility goal of ±2 ppb for atmospheric CO concentration measurements. Therefore, the EMRP-HIGHGAS (European metrology research program - high-impact greenhouse gases) project aims at developing spectroscopic transfer standards for CO concentration measurements to meet this goal. A spectroscopic transfer standard would provide results that are directly traceable to the SI, can be very useful for calibration of devices operating in the field, and could complement classical gas standards in the field where calibration gas mixtures in bottles often are not accurate, available or stable enough [1][2]. Here, we present our new direct tunable diode laser absorption spectroscopy (dTDLAS) sensor capable of performing absolute ("calibration free") CO concentration measurements, and being operated as a spectroscopic transfer standard. To achieve the compatibility goal stated by WMO for CO concentration measurements and ensure the traceability of the final concentration results, traceable spectral line data especially line intensities with appropriate uncertainties are needed. Therefore, we utilize our new high-resolution Fourier-transform infrared (FTIR) spectroscopy CO line data for the 2-0 band, with significantly reduced uncertainties, for the dTDLAS data evaluation. Further, we demonstrate the capability of our sensor for atmospheric CO measurements, discuss uncertainty calculation following the guide to the expression of uncertainty in measurement (GUM) principles and show that CO concentrations derived using the sensor, based on the TILSAM (traceable infrared laser spectroscopic amount fraction measurement) method, are in excellent agreement with gravimetric values. Acknowledgement Parts of this work have been

  18. Raman spectroscopy for highly accurate estimation of the age of refrigerated porcine muscle

    Science.gov (United States)

    Timinis, Constantinos; Pitris, Costas

    2016-03-01

    The high water content of meat, combined with all the nutrients it contains, make it vulnerable to spoilage at all stages of production and storage even when refrigerated at 5 °C. A non-destructive and in situ tool for meat sample testing, which could provide an accurate indication of the storage time of meat, would be very useful for the control of meat quality as well as for consumer safety. The proposed solution is based on Raman spectroscopy which is non-invasive and can be applied in situ. For the purposes of this project, 42 meat samples from 14 animals were obtained and three Raman spectra per sample were collected every two days for two weeks. The spectra were subsequently processed and the sample age was calculated using a set of linear differential equations. In addition, the samples were classified in categories corresponding to the age in 2-day steps (i.e., 0, 2, 4, 6, 8, 10, 12 or 14 days old), using linear discriminant analysis and cross-validation. Contrary to other studies, where the samples were simply grouped into two categories (higher or lower quality, suitable or unsuitable for human consumption, etc.), in this study, the age was predicted with a mean error of ~ 1 day (20%) or classified, in 2-day steps, with 100% accuracy. Although Raman spectroscopy has been used in the past for the analysis of meat samples, the proposed methodology has resulted in a prediction of the sample age far more accurately than any report in the literature.

  19. Fast and accurate: high-speed metrological large-range AFM for surface and nanometrology

    Science.gov (United States)

    Dai, Gaoliang; Koenders, Ludger; Fluegge, Jens; Hemmleb, Matthias

    2018-05-01

    Low measurement speed remains a major shortcoming of the scanning probe microscopic technique. It not only leads to a low measurement throughput, but a significant measurement drift over the long measurement time needed (up to hours or even days). To overcome this challenge, PTB, the national metrology institute of Germany, has developed a high-speed metrological large-range atomic force microscope (HS Met. LR-AFM) capable of measuring speeds up to 1 mm s‑1. This paper has introduced the design concept in detail. After modelling scanning probe microscopic measurements, our results suggest that the signal spectrum of the surface to be measured is the spatial spectrum of the surface scaled by the scanning speed. The higher the scanning speed , the broader the spectrum to be measured. To realise an accurate HS Met. LR-AFM, our solution is to combine different stages/sensors synchronously in measurements, which provide a much larger spectrum area for high-speed measurement capability. Two application examples have been demonstrated. The first is a new concept called reference areal surface metrology. Using the developed HS Met. LR-AFM, surfaces are measured accurately and traceably at a speed of 500 µm s‑1 and the results are applied as a reference 3D data map of the surfaces. By correlating the reference 3D data sets and 3D data sets of tools under calibration, which are measured at the same surface, it has the potential to comprehensively characterise the tools, for instance, the spectrum properties of the tools. The investigation results of two commercial confocal microscopes are demonstrated, indicating very promising results. The second example is the calibration of a kind of 3D nano standard, which has spatially distributed landmarks, i.e. special unique features defined by 3D-coordinates. Experimental investigations confirmed that the calibration accuracy is maintained at a measurement speed of 100 µm s‑1, which improves the calibration efficiency by a

  20. Accurate evaluation for the biofilm-activated sludge reactor using graphical techniques

    Science.gov (United States)

    Fouad, Moharram; Bhargava, Renu

    2018-05-01

    A complete graphical solution is obtained for the completely mixed biofilm-activated sludge reactor (hybrid reactor). The solution consists of a series of curves deduced from the principal equations of the hybrid system after converting them in dimensionless form. The curves estimate the basic parameters of the hybrid system such as suspended biomass concentration, sludge residence time, wasted mass of sludge, and food to biomass ratio. All of these parameters can be expressed as functions of hydraulic retention time, influent substrate concentration, substrate concentration in the bulk, stagnant liquid layer thickness, and the minimum substrate concentration which can maintain the biofilm growth in addition to the basic kinetics of the activated sludge process in which all these variables are expressed in a dimensionless form. Compared to other solutions of such system these curves are simple, easy to use, and provide an accurate tool for analyzing such system based on fundamental principles. Further, these curves may be used as a quick tool to get the effect of variables change on the other parameters and the whole system.

  1. Decision Fusion Based on Hyperspectral and Multispectral Satellite Imagery for Accurate Forest Species Mapping

    Directory of Open Access Journals (Sweden)

    Dimitris G. Stavrakoudis

    2014-07-01

    Full Text Available This study investigates the effectiveness of combining multispectral very high resolution (VHR and hyperspectral satellite imagery through a decision fusion approach, for accurate forest species mapping. Initially, two fuzzy classifications are conducted, one for each satellite image, using a fuzzy output support vector machine (SVM. The classification result from the hyperspectral image is then resampled to the multispectral’s spatial resolution and the two sources are combined using a simple yet efficient fusion operator. Thus, the complementary information provided from the two sources is effectively exploited, without having to resort to computationally demanding and time-consuming typical data fusion or vector stacking approaches. The effectiveness of the proposed methodology is validated in a complex Mediterranean forest landscape, comprising spectrally similar and spatially intermingled species. The decision fusion scheme resulted in an accuracy increase of 8% compared to the classification using only the multispectral imagery, whereas the increase was even higher compared to the classification using only the hyperspectral satellite image. Perhaps most importantly, its accuracy was significantly higher than alternative multisource fusion approaches, although the latter are characterized by much higher computation, storage, and time requirements.

  2. Predicting Falls in People with Multiple Sclerosis: Fall History Is as Accurate as More Complex Measures

    Directory of Open Access Journals (Sweden)

    Michelle H. Cameron

    2013-01-01

    Full Text Available Background. Many people with MS fall, but the best method for identifying those at increased fall risk is not known. Objective. To compare how accurately fall history, questionnaires, and physical tests predict future falls and injurious falls in people with MS. Methods. 52 people with MS were asked if they had fallen in the past 2 months and the past year. Subjects were also assessed with the Activities-specific Balance Confidence, Falls Efficacy Scale-International, and Multiple Sclerosis Walking Scale-12 questionnaires, the Expanded Disability Status Scale, Timed 25-Foot Walk, and computerized dynamic posturography and recorded their falls daily for the following 6 months with calendars. The ability of baseline assessments to predict future falls was compared using receiver operator curves and logistic regression. Results. All tests individually provided similar fall prediction (area under the curve (AUC 0.60–0.75. A fall in the past year was the best predictor of falls (AUC 0.75, sensitivity 0.89, specificity 0.56 or injurious falls (AUC 0.69, sensitivity 0.96, specificity 0.41 in the following 6 months. Conclusion. Simply asking people with MS if they have fallen in the past year predicts future falls and injurious falls as well as more complex, expensive, or time-consuming approaches.

  3. An accurate and nondestructive GC method for determination of cocaine on US paper currency.

    Science.gov (United States)

    Zuo, Yuegang; Zhang, Kai; Wu, Jingping; Rego, Christopher; Fritz, John

    2008-07-01

    The presence of cocaine on US paper currency has been known for a long time. Banknotes become contaminated during the exchange, storage, and abuse of cocaine. The analysis of cocaine on various denominations of US banknotes in the general circulation can provide law enforcement circles and forensic epidemiologists objective and timely information on epidemiology of illicit drug use and on how to differentiate money contaminated in the general circulation from banknotes used in drug transaction. A simple, nondestructive, and accurate capillary gas chromatographic method has been developed for the determination of cocaine on various denominations of US banknotes in this study. The method comprises a fast ultrasonic extraction using water as a solvent followed by a SPE cleanup process with a C(18) cartridge and capillary GC separation, identification, and quantification. This nondestructive analytical method has been successfully applied to determine the cocaine contamination in US paper currency of all denominations. Standard calibration curve was linear over the concentration range from the LOQ (2.00 ng/mL) to 100 microg/mL and the RSD less than 2.0%. Cocaine was detected in 67% of the circulated banknotes collected in Southeastern Massachusetts in amounts ranging from approximately 2 ng to 49.4 microg per note. On average, $5, 10, 20, and 50 denominations contain higher amounts of cocaine than $1 and 100 denominations of US banknotes.

  4. Fast and accurate taxonomic assignments of metagenomic sequences using MetaBin.

    Directory of Open Access Journals (Sweden)

    Vineet K Sharma

    Full Text Available Taxonomic assignment of sequence reads is a challenging task in metagenomic data analysis, for which the present methods mainly use either composition- or homology-based approaches. Though the homology-based methods are more sensitive and accurate, they suffer primarily due to the time needed to generate the Blast alignments. We developed the MetaBin program and web server for better homology-based taxonomic assignments using an ORF-based approach. By implementing Blat as the faster alignment method in place of Blastx, the analysis time has been reduced by severalfold. It is benchmarked using both simulated and real metagenomic datasets, and can be used for both single and paired-end sequence reads of varying lengths (≥45 bp. To our knowledge, MetaBin is the only available program that can be used for the taxonomic binning of short reads (<100 bp with high accuracy and high sensitivity using a homology-based approach. The MetaBin web server can be used to carry out the taxonomic analysis, by either submitting reads or Blastx output. It provides several options including construction of taxonomic trees, creation of a composition chart, functional analysis using COGs, and comparative analysis of multiple metagenomic datasets. MetaBin web server and a standalone version for high-throughput analysis are available freely at http://metabin.riken.jp/.

  5. Accurate diagnosis of CHD by Paediatricians with Expertise in Cardiology.

    Science.gov (United States)

    Jacob, Hannah C; Massey, Hannah; Yates, Robert W M; Kelsall, A Wilfred

    2017-08-01

    Introduction Paediatricians with Expertise in Cardiology assess children with a full history, examination, and often perform an echocardiogram. A minority are then referred to an outreach clinic run jointly with a visiting paediatric cardiologist. The accuracy of the echocardiography diagnosis made by the Paediatrician with Expertise in Cardiology is unknown. Materials and methods We conducted a retrospective review of clinic letters for children seen in the outreach clinic for the first time between March, 2004 and March, 2011. Children with CHD diagnosed antenatally or elsewhere were excluded. We recorded the echocardiography diagnosis made by the paediatric cardiologist and previously by the Paediatrician with Expertise in Cardiology. The Paediatrician with Expertise in Cardiology referred 317/3145 (10%) children seen in the local cardiac clinics to the outreach clinic over this period, and among them 296 were eligible for inclusion. Their median age was 1.5 years (range 1 month-15.1 years). For 244 (82%) children, there was complete diagnostic agreement between the Paediatrician with Expertise in Cardiology and the paediatric cardiologist. For 29 (10%) children, the main diagnosis was identical with additional findings made by the paediatric cardiologist. The abnormality had resolved in 17 (6%) cases by the time of clinic attendance. In six (2%) patients, the paediatric cardiologist made a different diagnosis. In total, 138 (47%) patients underwent a surgical or catheter intervention. Discussion Paediatricians with Expertise in Cardiology can make accurate diagnoses of CHD in children referred to their clinics. This can allow effective triage of children attending the outreach clinic, making best use of limited specialist resources.

  6. How accurate are the weather forecasts for Bierun (southern Poland)?

    Science.gov (United States)

    Gawor, J.

    2012-04-01

    Weather forecast accuracy has increased in recent times mainly thanks to significant development of numerical weather prediction models. Despite the improvements, the forecasts should be verified to control their quality. The evaluation of forecast accuracy can also be an interesting learning activity for students. It joins natural curiosity about everyday weather and scientific process skills: problem solving, database technologies, graph construction and graphical analysis. The examination of the weather forecasts has been taken by a group of 14-year-old students from Bierun (southern Poland). They participate in the GLOBE program to develop inquiry-based investigations of the local environment. For the atmospheric research the automatic weather station is used. The observed data were compared with corresponding forecasts produced by two numerical weather prediction models, i.e. COAMPS (Coupled Ocean/Atmosphere Mesoscale Prediction System) developed by Naval Research Laboratory Monterey, USA; it runs operationally at the Interdisciplinary Centre for Mathematical and Computational Modelling in Warsaw, Poland and COSMO (The Consortium for Small-scale Modelling) used by the Polish Institute of Meteorology and Water Management. The analysed data included air temperature, precipitation, wind speed, wind chill and sea level pressure. The prediction periods from 0 to 24 hours (Day 1) and from 24 to 48 hours (Day 2) were considered. The verification statistics that are commonly used in meteorology have been applied: mean error, also known as bias, for continuous data and a 2x2 contingency table to get the hit rate and false alarm ratio for a few precipitation thresholds. The results of the aforementioned activity became an interesting basis for discussion. The most important topics are: 1) to what extent can we rely on the weather forecasts? 2) How accurate are the forecasts for two considered time ranges? 3) Which precipitation threshold is the most predictable? 4) Why

  7. Achieving target voriconazole concentrations more accurately in children and adolescents.

    Science.gov (United States)

    Neely, Michael; Margol, Ashley; Fu, Xiaowei; van Guilder, Michael; Bayard, David; Schumitzky, Alan; Orbach, Regina; Liu, Siyu; Louie, Stan; Hope, William

    2015-01-01

    Despite the documented benefit of voriconazole therapeutic drug monitoring, nonlinear pharmacokinetics make the timing of steady-state trough sampling and appropriate dose adjustments unpredictable by conventional methods. We developed a nonparametric population model with data from 141 previously richly sampled children and adults. We then used it in our multiple-model Bayesian adaptive control algorithm to predict measured concentrations and doses in a separate cohort of 33 pediatric patients aged 8 months to 17 years who were receiving voriconazole and enrolled in a pharmacokinetic study. Using all available samples to estimate the individual Bayesian posterior parameter values, the median percent prediction bias relative to a measured target trough concentration in the patients was 1.1% (interquartile range, -17.1 to 10%). Compared to the actual dose that resulted in the target concentration, the percent bias of the predicted dose was -0.7% (interquartile range, -7 to 20%). Using only trough concentrations to generate the Bayesian posterior parameter values, the target bias was 6.4% (interquartile range, -1.4 to 14.7%; P = 0.16 versus the full posterior parameter value) and the dose bias was -6.7% (interquartile range, -18.7 to 2.4%; P = 0.15). Use of a sample collected at an optimal time of 4 h after a dose, in addition to the trough concentration, resulted in a nonsignificantly improved target bias of 3.8% (interquartile range, -13.1 to 18%; P = 0.32) and a dose bias of -3.5% (interquartile range, -18 to 14%; P = 0.33). With the nonparametric population model and trough concentrations, our control algorithm can accurately manage voriconazole therapy in children independently of steady-state conditions, and it is generalizable to any drug with a nonparametric pharmacokinetic model. (This study has been registered at ClinicalTrials.gov under registration no. NCT01976078.). Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  8. Valued Information at the Right Time (VIRT) and the Navy's Cooperative Engagement Capability (CEC) - A Win/Win Proposition

    National Research Council Canada - National Science Library

    Acevedo, Rafael A

    2006-01-01

    In this thesis I examine the theory of Valued Information at the Right Time (VIRT) and the benefits its implementation can provide to the Navy's best example of accurate information-sharing, the Cooperative Engagement Capability...

  9. Accurately bearing measurement in non-cooperative passive location system

    International Nuclear Information System (INIS)

    Liu Zhiqiang; Ma Hongguang; Yang Lifeng

    2007-01-01

    The system of non-cooperative passive location based on array is proposed. In the system, target is detected by beamforming and Doppler matched filtering; and bearing is measured by a long-base-ling interferometer which is composed of long distance sub-arrays. For the interferometer with long-base-line, the bearing is measured accurately but ambiguously. To realize unambiguous accurately bearing measurement, beam width and multiple constraint adoptive beamforming technique is used to resolve azimuth ambiguous. Theory and simulation result shows this method is effective to realize accurately bearing measurement in no-cooperate passive location system. (authors)

  10. Accurate modeling and maximum power point detection of ...

    African Journals Online (AJOL)

    Accurate modeling and maximum power point detection of photovoltaic ... Determination of MPP enables the PV system to deliver maximum available power. ..... adaptive artificial neural network: Proposition for a new sizing procedure.

  11. Accurate determination of light elements by charged particle activation analysis

    International Nuclear Information System (INIS)

    Shikano, K.; Shigematsu, T.

    1989-01-01

    To develop accurate determination of light elements by CPAA, accurate and practical standardization methods and uniform chemical etching are studied based on determination of carbon in gallium arsenide using the 12 C(d,n) 13 N reaction and the following results are obtained: (1)Average stopping power method with thick target yield is useful as an accurate and practical standardization method. (2)Front surface of sample has to be etched for accurate estimate of incident energy. (3)CPAA is utilized for calibration of light element analysis by physical method. (4)Calibration factor of carbon analysis in gallium arsenide using the IR method is determined to be (9.2±0.3) x 10 15 cm -1 . (author)

  12. ACCURATE ESTIMATES OF CHARACTERISTIC EXPONENTS FOR SECOND ORDER DIFFERENTIAL EQUATION

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    In this paper, a second order linear differential equation is considered, and an accurate estimate method of characteristic exponent for it is presented. Finally, we give some examples to verify the feasibility of our result.

  13. Importance of molecular diagnosis in the accurate diagnosis of ...

    Indian Academy of Sciences (India)

    1Department of Health and Environmental Sciences, Kyoto University Graduate School of Medicine, Yoshida Konoecho, ... of molecular diagnosis in the accurate diagnosis of systemic carnitine deficiency. .... 'affecting protein function' by SIFT.

  14. Decision support system of e-book provider selection for library using Simple Additive Weighting

    Science.gov (United States)

    Ciptayani, P. I.; Dewi, K. C.

    2018-01-01

    Each library has its own criteria and differences in the importance of each criterion in choosing an e-book provider for them. The large number of providers and the different importance levels of each criterion make the problem of determining the e-book provider to be complex and take a considerable time in decision making. The aim of this study was to implement Decision support system (DSS) to assist the library in selecting the best e-book provider based on their preferences. The way of DSS works is by comparing the importance of each criterion and the condition of each alternative decision. SAW is one of DSS method that is quite simple, fast and widely used. This study used 9 criteria and 18 provider to demonstrate how SAW work in this study. With the DSS, then the decision-making time can be shortened and the calculation results can be more accurate than manual calculations.

  15. An accurate metric for the spacetime around neutron stars

    OpenAIRE

    Pappas, George

    2016-01-01

    The problem of having an accurate description of the spacetime around neutron stars is of great astrophysical interest. For astrophysical applications, one needs to have a metric that captures all the properties of the spacetime around a neutron star. Furthermore, an accurate appropriately parameterised metric, i.e., a metric that is given in terms of parameters that are directly related to the physical structure of the neutron star, could be used to solve the inverse problem, which is to inf...

  16. Accurate forced-choice recognition without awareness of memory retrieval

    OpenAIRE

    Voss, Joel L.; Baym, Carol L.; Paller, Ken A.

    2008-01-01

    Recognition confidence and the explicit awareness of memory retrieval commonly accompany accurate responding in recognition tests. Memory performance in recognition tests is widely assumed to measure explicit memory, but the generality of this assumption is questionable. Indeed, whether recognition in nonhumans is always supported by explicit memory is highly controversial. Here we identified circumstances wherein highly accurate recognition was unaccompanied by hallmark features of explicit ...

  17. Accurate radiotherapy positioning system investigation based on video

    International Nuclear Information System (INIS)

    Tao Shengxiang; Wu Yican

    2006-01-01

    This paper introduces the newest research production on patient positioning method in accurate radiotherapy brought by Accurate Radiotherapy Treating System (ARTS) research team of Institute of Plasma Physics of Chinese Academy of Sciences, such as the positioning system based on binocular vision, the position-measuring system based on contour matching and the breath gate controlling system for positioning. Their basic principle, the application occasion and the prospects are briefly depicted. (authors)

  18. Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system

    Energy Technology Data Exchange (ETDEWEB)

    Poulin, Eric; Racine, Emmanuel; Beaulieu, Luc, E-mail: Luc.Beaulieu@phy.ulaval.ca [Département de physique, de génie physique et d’optique et Centre de recherche sur le cancer de l’Université Laval, Université Laval, Québec, Québec G1V 0A6, Canada and Département de radio-oncologie et Axe Oncologie du Centre de recherche du CHU de Québec, CHU de Québec, 11 Côte du Palais, Québec, Québec G1R 2J6 (Canada); Binnekamp, Dirk [Integrated Clinical Solutions and Marketing, Philips Healthcare, Veenpluis 4-6, Best 5680 DA (Netherlands)

    2015-03-15

    Purpose: In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this technical note is to evaluate the accuracy and the robustness of an electromagnetic (EM) tracking system for automated and real-time catheter reconstruction. Methods: For this preclinical study, a total of ten catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a 18G biopsy needle, used as an EM stylet and equipped with a miniaturized sensor, and the second generation Aurora{sup ®} Planar Field Generator from Northern Digital Inc. The Aurora EM system provides position and orientation value with precisions of 0.7 mm and 0.2°, respectively. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical computed tomography (CT) system with a spatial resolution of 89 μm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, five catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 s, leading to a total reconstruction time inferior to 3 min for a typical 17-catheter implant. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.66 ± 0.33 mm and 1.08 ± 0.72 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be more accurate. A maximum difference of less than 0.6 mm was found between successive EM reconstructions. Conclusions: The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators.

  19. Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system

    International Nuclear Information System (INIS)

    Poulin, Eric; Racine, Emmanuel; Beaulieu, Luc; Binnekamp, Dirk

    2015-01-01

    Purpose: In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this technical note is to evaluate the accuracy and the robustness of an electromagnetic (EM) tracking system for automated and real-time catheter reconstruction. Methods: For this preclinical study, a total of ten catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a 18G biopsy needle, used as an EM stylet and equipped with a miniaturized sensor, and the second generation Aurora ® Planar Field Generator from Northern Digital Inc. The Aurora EM system provides position and orientation value with precisions of 0.7 mm and 0.2°, respectively. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical computed tomography (CT) system with a spatial resolution of 89 μm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, five catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 s, leading to a total reconstruction time inferior to 3 min for a typical 17-catheter implant. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.66 ± 0.33 mm and 1.08 ± 0.72 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be more accurate. A maximum difference of less than 0.6 mm was found between successive EM reconstructions. Conclusions: The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators

  20. Accurate costs of blood transfusion: a microcosting of administering blood products in the United Kingdom National Health Service.

    Science.gov (United States)

    Stokes, Elizabeth A; Wordsworth, Sarah; Staves, Julie; Mundy, Nicola; Skelly, Jane; Radford, Kelly; Stanworth, Simon J

    2018-04-01

    In an environment of limited health care resources, it is crucial for health care systems which provide blood transfusion to have accurate and comprehensive information on the costs of transfusion, incorporating not only the costs of blood products, but also their administration. Unfortunately, in many countries accurate costs for administering blood are not available. Our study aimed to generate comprehensive estimates of the costs of administering transfusions for the UK National Health Service. A detailed microcosting study was used to cost two key inputs into transfusion: transfusion laboratory and nursing inputs. For each input, data collection forms were developed to capture staff time, equipment, and consumables associated with each step in the transfusion process. Costing results were combined with costs of blood product wastage to calculate the cost per unit transfused, separately for different blood products. Data were collected in 2014/15 British pounds and converted to US dollars. A total of 438 data collection forms were completed by 74 staff. The cost of administering blood was $71 (£49) per unit for red blood cells, $84 (£58) for platelets, $55 (£38) for fresh-frozen plasma, and $72 (£49) for cryoprecipitate. Blood administration costs add substantially to the costs of the blood products themselves. These are frequently incurred costs; applying estimates to the blood components supplied to UK hospitals in 2015, the annual cost of blood administration, excluding blood products, exceeds $175 (£120) million. These results provide more accurate estimates of the total costs of transfusion than those previously available. © 2018 AABB.