WorldWideScience

Sample records for prototypical office building

  1. Courthouse Prototype Building

    Energy Technology Data Exchange (ETDEWEB)

    Malhotra, Mini [ORNL; New, Joshua Ryan [ORNL; Im, Piljae [ORNL

    2018-02-01

    As part of DOE's support of ANSI/ASHRAE/IES Standard 90.1 and IECC, researchers at Pacific Northwest National Laboratory (PNNL) apply a suite of prototype buildings covering 80% of the commercial building floor area in the U.S. for new construction. Efforts have started on expanding the prototype building suite to cover 90% of the commercial building floor area in the U.S., by developing prototype models for additional building types including place of worship, public order and safety, public assembly. Courthouse is courthouse is a sub-category under the “Public Order and Safety" building type category; other sub-categories include police station, fire station, and jail, reformatory or penitentiary.ORNL used building design guides, databases, and documented courthouse projects, supplemented by personal communication with courthouse facility planning and design experts, to systematically conduct research on the courthouse building and system characteristics. This report documents the research conducted for the courthouse building type and proposes building and system characteristics for developing a prototype building energy model to be included in the Commercial Building Prototype Model suite. According to the 2012 CBECS, courthouses occupy a total of 436 million sqft of floor space or 0.5% of the total floor space in all commercial buildings in the US, next to fast food (0.35%), grocery store or food market (0.88%), and restaurant or cafeteria (1.2%) building types currently included in the Commercial Prototype Building Model suite. Considering aggregated average, courthouse falls among the larger with a mean floor area of 69,400 sqft smaller fuel consumption intensity building types and an average of 94.7 kBtu/sqft compared to 77.8 kBtu/sqft for office and 80 kBtu/sqft for all commercial buildings.Courthouses range in size from 1000 sqft to over a million square foot building gross square feet and 1 courtroom to over 100 courtrooms. Small courthouses

  2. Prototype of smart office system using based security system

    Science.gov (United States)

    Prasetyo, T. F.; Zaliluddin, D.; Iqbal, M.

    2018-05-01

    Creating a new technology in the modern era gives a positive impact on business and industry. Internet of Things (IoT) as a new communication technology is very useful in realizing smart systems such as: smart home, smart office, smart parking and smart city. This study presents a prototype of the smart office system which was designed as a security system based on IoT. Smart office system development method used waterfall model. IoT-based smart office system used platform (project builder) cayenne so that. The data can be accessed and controlled through internet network from long distance. Smart office system used arduino mega 2560 microcontroller as a controller component. In this study, Smart office system is able to detect threats of dangerous objects made from metals, earthquakes, fires, intruders or theft and perform security monitoring outside the building by using raspberry pi cameras on autonomous robots in real time to the security guard.

  3. Technical Support Document: Development of the Advanced Energy Design Guide for Small Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Jarnagin, Ronald E.; Liu, Bing; Winiarski, David W.; McBride, Merle F.; Suharli, L.; Walden, D.

    2006-11-30

    This Technical Support Document (TSD) describes the process and methodology for the development of the Advanced Energy Design Guide for Small Office Buildings (AEDG-SO), a design guidance document intended to provide recommendations for achieving 30% energy savings in small office buildings over levels contained in ANSI/ASHRAE/IESNA Standard 90.1-1999, Energy Standard for Buildings Except Low-Rise Residential Buildings. The AEDG-SO is the first in a series of guides being developed by a partnership of organizations, including the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (ASHRAE), the American Institute of Architects (AIA), the Illuminating Engineering Society of North America (IESNA), the New Buildings Institute (NBI), and the U.S. Department of Energy (DOE). Each of the guides in the AEDG series will provide recommendations and user-friendly design assistance to designers, developers and owners of small commercial buildings that will encourage steady progress towards net-zero energy buildings. The guides will provide prescriptive recommendation packages that are capable of reaching the energy savings target for each climate zone in order to ease the burden of the design and construction of energy-efficient small commercial buildings The AEDG-SO was developed by an ASHRAE Special Project committee (SP-102) made up of representatives of each of the partner organizations in eight months. This TSD describes the charge given to the committee in developing the office guide and outlines the schedule of the development effort. The project committee developed two prototype office buildings (5,000 ft2 frame building and 20,000 ft2 two-story mass building) to represent the class of small office buildings and performed an energy simulation scoping study to determine the preliminary levels of efficiency necessary to meet the energy savings target. The simulation approach used by the project committee is documented in this TSD along with

  4. Performance of a daylight redirecting glass shading system demonstration in an office building

    DEFF Research Database (Denmark)

    Appelfeld, David; Svendsen, Svend; Traberg-Borup, Steen

    2011-01-01

    This paper evaluates the daylighting performance of a prototype external dynamic integrated shading and light redirecting system. The demonstration project was carried out on a building with an open-plan office. The prototype and original façades were placed on the same floor with the same...... orientation and similar surroundings. The existing façade was used as the reference for measurements and simulations. The focus of this research project was to employ available simulation tools for the system performance evaluation. This was accompanied by measurements of the daylight conditions...... in the investigated space. The prototype system improved daylighting conditions compared to the existing shading system....

  5. Technical Support Document: Strategies for 50% Energy Savings in Large Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Leach, M.; Lobato, C.; Hirsch, A.; Pless, S.; Torcellini, P.

    2010-09-01

    This Technical Support Document (TSD) documents technical analysis that informs design guidance for designing and constructing large office buildings that achieve 50% net site energy savings over baseline buildings defined by minimal compliance with respect to ANSI/ASHRAE/IESNA Standard 90.1-2004. This report also represents a step toward developing a methodology for using energy modeling in the design process to achieve aggressive energy savings targets. This report documents the modeling and analysis methods used to identify design recommendations for six climate zones that capture the range of U.S. climate variability; demonstrates how energy savings change between ASHRAE Standard 90.1-2007 and Standard 90.1-2004 to determine baseline energy use; uses a four-story 'low-rise' prototype to analyze the effect of building aspect ratio on energy use intensity; explores comparisons between baseline and low-energy building energy use for alternate energy metrics (net source energy, energy emissions, and energy cost); and examines the extent to which glass curtain construction limits achieve energy savings by using a 12-story 'high-rise' prototype.

  6. Energy use in office buildings

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-10-01

    This is the report on Task IB, Familiarization with Additional Data Collection Plans of Annual Survey of BOMA Member and Non-Member Buildings in 20 Cities, of the Energy Use in Office Buildings project. The purpose of the work was to monitor and understand the efforts of the Building Owners and Managers Association International (BOMA) in gathering an energy-use-oriented data base. In order to obtain an improved data base encompassing a broad spectrum of office space and with information suitable for energy analysis in greater detail than is currently available, BOMA undertook a major data-collection effort. Based on a consideration of geographic area, climate, population, and availability of data, BOMA selected twenty cities for data collection. BOMA listed all of the major office space - buildings in excess of 40,000 square feet - in each of the cities. Tax-assessment records, local maps, Chamber of Commerce data, recent industrial-development programs, results of related studies, and local-realtor input were used in an effort to assemble a comprehensive office-building inventory. In order to verify the accuracy and completeness of the building lists, BOMA assembled an Ad-Hoc Review Committee in each city to review the assembled inventory of space. A questionnaire on office-building energy use and building characteristics was developed. In each city BOMA assembled a data collection team operating under the supervision of its regional affiliate to gather the data. For each city a random sample of buildings was selected, and data were gathered. Responses for over 1000 buildings were obtained.

  7. 11 CFR 300.35 - Office buildings.

    Science.gov (United States)

    2010-01-01

    ... 11 Federal Elections 1 2010-01-01 2010-01-01 false Office buildings. 300.35 Section 300.35 Federal... FUNDS State, District, and Local Party Committees and Organizations § 300.35 Office buildings. (a) General provision. For the purchase or construction of its office building, a State or local party...

  8. Consumer Central Energy Flexibility in Office Buildings

    DEFF Research Database (Denmark)

    Billanes, Joy Dalmacio; Ma, Zheng; Jørgensen, Bo Nørregaard

    2017-01-01

    Energy flexibility in buildings will play an important role in the smart energy system. Office buildings have more potentials to provide energy flexibility to the grid compared to other types of buildings, due to the existing building management, control systems and large energy consumption....... Consumers in office buildings (building owners/managers and occupants) take a main role for adopting and engaging in building energy flexibility. In this paper provides a systematic review of consumer central energy flexibility in office buildings with the discussion of social, technical and business...... can boost energy flexibility in the office buildings....

  9. Building a Prototype Text to Speech for Sanskrit

    Science.gov (United States)

    Mahananda, Baiju; Raju, C. M. S.; Patil, Ramalinga Reddy; Jha, Narayana; Varakhedi, Shrinivasa; Kishore, Prahallad

    This paper describes about the work done in building a prototype text to speech system for Sanskrit. A basic prototype text-to-speech is built using a simplified Sanskrit phone set, and employing a unit selection technique, where prerecorded sub-word units are concatenated to synthesize a sentence. We also discuss the issues involved in building a full-fledged text-to-speech for Sanskrit.

  10. Tropical Zero Energy Office Building

    DEFF Research Database (Denmark)

    Reimann, Gregers Peter; Kristensen, Poul Erik

    2006-01-01

    The new headquarter for Pusat Tenaga Malaysia is designed to be a Zero Emission Office Building (ZEO). A full range of passive and active energy efficiency measures are implemented such that the building will need no more electricity than what can be produced via its own Building Integrated PV...... lighting. These measures include the use of high efficient lighting controlled according to demand, high efficiency pumps and fans, a high efficiency chiller, and use of energy efficient office equipment. The buildings PV system is connected to the grid. Solar electricity is exported to the grid during...... of 24 – 26 oC can be maintained throughout the office hours. The PV roof of the building serves multiple purposes. During daytime, the roof becomes the powerplant of the building, and during nighttime, the PV roof becomes the “cooling tower” for the chiller. The roof will be covered by a thin water film...

  11. Enhancements to ASHRAE Standard 90.1 Prototype Building Models

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya; Athalye, Rahul A.; Wang, Weimin; Zhang, Jian; Rosenberg, Michael I.; Xie, YuLong; Hart, Philip R.; Mendon, Vrushali V.

    2014-04-16

    This report focuses on enhancements to prototype building models used to determine the energy impact of various versions of ANSI/ASHRAE/IES Standard 90.1. Since the last publication of the prototype building models, PNNL has made numerous enhancements to the original prototype models compliant with the 2004, 2007, and 2010 editions of Standard 90.1. Those enhancements are described here and were made for several reasons: (1) to change or improve prototype design assumptions; (2) to improve the simulation accuracy; (3) to improve the simulation infrastructure; and (4) to add additional detail to the models needed to capture certain energy impacts from Standard 90.1 improvements. These enhancements impact simulated prototype energy use, and consequently impact the savings estimated from edition to edition of Standard 90.1.

  12. On variations of space-heating energy use in office buildings

    International Nuclear Information System (INIS)

    Lin, Hung-Wen; Hong, Tianzhen

    2013-01-01

    Highlights: • Space heating is the largest energy end use in the U.S. building sector. • A key design and operational parameters have the most influence on space heating. • Simulated results were benchmarked against actual results to analyze discrepancies. • Yearly weather changes have significant impact on space heating energy use. • Findings enable stakeholders to make better decisions on energy efficiency. - Abstract: Space heating is the largest energy end use, consuming more than seven quintillion joules of site energy annually in the U.S. building sector. A few recent studies showed discrepancies in simulated space-heating energy use among different building energy modeling programs, and the simulated results are suspected to be underpredicting reality. While various uncertainties are associated with building simulations, especially when simulations are performed by different modelers using different simulation programs for buildings with different configurations, it is crucial to identify and evaluate key driving factors to space-heating energy use in order to support the design and operation of low-energy buildings. In this study, 10 design and operation parameters for space-heating systems of two prototypical office buildings in each of three U.S. heating climates are identified and evaluated, using building simulations with EnergyPlus, to determine the most influential parameters and their impacts on variations of space-heating energy use. The influence of annual weather change on space-heating energy is also investigated using 30-year actual weather data. The simulated space-heating energy use is further benchmarked against those from similar actual office buildings in two U.S. commercial-building databases to better understand the discrepancies between simulated and actual energy use. In summary, variations of both the simulated and actual space-heating energy use of office buildings in all three heating climates can be very large. However

  13. 78 FR 69839 - Building Technologies Office Prioritization Tool

    Science.gov (United States)

    2013-11-21

    ... standards and building codes to ensure energy savings within buildings. BTO has developed a new technology... DEPARTMENT OF ENERGY Building Technologies Office Prioritization Tool AGENCY: Office of Energy....S. Department of Energy's (DOE) Building Technologies Office (BTO) developed the Prioritization Tool...

  14. Performance analysis of an energy efficient building prototype by using TRNSYS

    OpenAIRE

    Lai, Kun; Wang, Wen; Giles, Harry

    2014-01-01

    Buildings section accouts for a large part of the total primary energy consumption. This paper reports a simulative study on an energy efficient building prototype named MIDMOD by using TRNSYS program. The prototype is a new genre of affordable medium density building concepts that are more adaptable, durable, and energy efficient as whole-life housing typologies than those currently available.The building envelope thermal insulation and air tightness are enhanced to reduce heat loss. Several...

  15. Building-related symptoms and inflammatory potency of dust from office buildings

    DEFF Research Database (Denmark)

    Allermann, L; Pejtersen, J; Gunnarsen, L

    2007-01-01

    UNLABELLED: The aim was to investigate the association between building-related symptoms (BRS) in office buildings and the inflammatory potency of dust (PD). Furthermore, the association between dust potency and various building characteristics was investigated. Occupants of 22 office buildings...... received a retrospective questionnaire about BRS (2301 respondents). Dust was collected from groups of offices and building characteristics were recorded. The potency of a dust sample to induce interleukin-8 (IL-8) secretion from the lung epithelial cell line A549 was measured as the slope of the initial...... linear part of the concentration-response curve. Symptoms of the central nervous system (CNS) were associated with the potency of surface dust (OR = 1.4). This association may be due to an association between an index of CNS symptoms and dust potency in offices of 1-6 occupants (OR = 1.5). No single...

  16. Building-related symptoms and inflammatory potency of dust from office buildings

    DEFF Research Database (Denmark)

    Allermann, Leila; Pejtersen, Jan; Gunnarsen, Lars Bo

    2007-01-01

    Abstract The aim was to investigate the association between building-related symptoms (BRS) in office buildings and the inflammatory potency of dust (PD). Furthermore, the association between dust potency and various building characteristics was investigated. Occupants of 22 office buildings...... received a retrospective questionnaire about BRS (2301 respondents). Dust was collected from groups of offices and building characteristics were recorded. The potency of a dust sample to induce interleukin-8 (IL-8) secretion from the lung epithelial cell line A549 was measured as the slope of the initial...... linear part of the concentration- response curve. Symptoms of the central nervous system (CNS) were associated with the potency of surface dust (OR ¼ 1.4). This association may be due to an association between an index of CNS symptoms and dust potency in offices of 1-6 occupants (OR ¼ 1.5). No single...

  17. 77 FR 24494 - Office of Federal High-Performance Green Buildings; Green Building Advisory Committee...

    Science.gov (United States)

    2012-04-24

    ... Federal High-Performance Green Buildings; Green Building Advisory Committee; Notification of Upcoming... agenda for the May 9, 2012, meeting of the Green Building Advisory Committee Meeting (the Committee). The... Sandler, Designated Federal Officer, Office of Federal High-Performance Green Buildings, Office of...

  18. Solar-Heated Office Building -- Dallas, Texas

    Science.gov (United States)

    1982-01-01

    Solar heating system designed to supply 87 percent of space heating and 100 percent of potable hot-water needs of large office building in Dallas, Texas. Unique feature of array serves as roofing over office lobby and gives building attractive triangular appearance. Report includes basic system drawings, test data, operating procedures, and maintenance instructions.

  19. Hawaii demand-side management resource assessment. Final report, Reference Volume 1: Building prototype analysis

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-01

    This report provides a detailed description of, and the baseline assumptions and simulation results for, the building prototype simulations conducted for the building types designated in the Work Plan for Demand-side Management Assessment of Hawaii`s Demand-Side Resources (HES-4, Phase 2). This report represents the second revision to the initial building prototype description report provided to DBEDT early in the project. Modifications and revisions to the prototypes, based on further calibration efforts and on comments received from DBEDT Staff have been incorporated into this final version. These baseline prototypes form the basis upon which the DSM measure impact estimates and the DSM measure data base were developed for this project. This report presents detailed information for each of the 17 different building prototypes developed for use with the DOE-21E program (23 buildings in total, including resorts and hotels defined separately for each island) to estimate the impact of the building technologies and measures included in this project. The remainder of this section presents some nomenclature and terminology utilized in the reports, tables, and data bases developed from this project to denote building type and vintage. Section 2 contains a more detailed discussion of the data sources, the definition of the residential sector building prototypes, and results of the DOE-2 analysis. Section 3 provides a similar discussion for the commercial sector. The prototype and baseline simulation results are presented in a separate section for each building type. Where possible, comparison of the baseline simulation results with benchmark data from the ENERGY 2020 model or other demand forecasting models specific to Hawaii is included for each building. Appendix A contains a detailed listing of the commercial sector baseline indoor lighting technologies included in the existing and new prototypes by building type.

  20. Sensory evaluation of the air in 14 office buildings

    DEFF Research Database (Denmark)

    Pejtersen, Jan; Schwab, R.; Mayer, E.

    1999-01-01

    The perceived air quality was assessed in eight mechanically and six naturally ventilated office buildings. On average, 44 offices were investigated in each building. A panel of 11 trained subjects assessed the perceived air quality in the spaces directly in the sensory unit decipol. The average...... perceived air quality in the 14 office buildings ranged from 3.4 to 7.8 decipol. The perceived air quality averaged 4.1 decipol in the mechanically ventilated buildings and 6.0 decipol in the naturally ventilated buildings. Within the buildings there was a large variation in perceived air quality between...... the offices. The results indicate that the occupants' behaviour is important for the pollution load and the air quality in offices....

  1. 76 FR 65511 - Office of Governmentwide Policy; Office of Federal High-Performance Green Buildings; the Green...

    Science.gov (United States)

    2011-10-21

    ... Governmentwide Policy; Office of Federal High- Performance Green Buildings; the Green Building Advisory Committee... meeting of the Green Building Advisory Committee Meeting (the Committee). The meeting is open to the..., Office of Federal High-Performance Green Buildings, Office of Governmentwide Policy, General Services...

  2. 10 CFR 434.504 - Use of the prototype building to determine the energy cost budget.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Use of the prototype building to determine the energy cost... Alternative § 434.504 Use of the prototype building to determine the energy cost budget. 504.1Determine the... Design. 504.2The form, orientation, occupancy and use profiles for the Prototype Building shall be fixed...

  3. Pusat Tenaga Malaysia's Zero Energy Office (ZEO) Building

    DEFF Research Database (Denmark)

    Tang, C.K.; Reimann, Gregers Peter; Kristensen, Poul Erik

    Technical Review of the Zero Energy Office building in Malaysia. The building, which has an energy index of 50 kWh/m2/year, reaches a net annual energy of zero through the use of building integrated photovoltaic panels. For reference, ordinary offices in Malaysia consume 200 - 300 kWh/m2/year...

  4. The impact of green building approach to office property value

    Science.gov (United States)

    Sitanggang, Yosephine; Susanto, Dalhar

    2017-12-01

    A real estate development often produces negative impacts towards the environment such as the reduction of the ecological capacity in the site and its surroundings, energy exploitation, and excessive pollutant emission. To overcome these issues, the green building concept or approach has been adapted by several real estate businesses in Indonesia especially in the office sector. According to the data provided by GBCI in 2017, there are 17 buildings listed as a certified green building office in various levels. As what has been known, the green building approach results in the increase of price in the planning, construction and the building's maintenance. This paper will discuss about the research results regarding the effect of the green building approach towards the property value of office buildings especially in Jakarta. The research will be executed through the comparison method, which is the process of comparing office building that have already adapted the green building concept with the one that have not, or in other words, the conventional office buildings. Data gathering is done through observation and interviews with developers and building managers. The research results show that by adapting the green building approach for office buildings in Jakarta, the property value regarding the utility, scarcity, effective demands, and transferability aspect can increase.

  5. Building envelope influence on the annual energy performance in office buildings

    Directory of Open Access Journals (Sweden)

    Harmati Norbert L.

    2016-01-01

    Full Text Available The objective of the research is to determine the quantitative influence of building envelope on the annual heating and cooling energy demand in office buildings demonstrated on a reference office-tower building located in Novi Sad, Serbia. The investigation intended to find preferable and applicable solutions for energy performance improvement in currently inefficient office buildings. A comparative and evaluative analysis was performed among the heating energy expenses and simulated values from the multi-zone model designed in EnergyPlus engine. The research determines an improved window to wall ratio using dynamic daylight simulation and presents the influence of glazing parameters (U-value, Solar heat gain coefficient - SHGC on the annual energy performance. Findings presented window to wall ratio reduction down to 30% and point out the significance of the SHGC parameter on the overall energy performance of buildings with high internal loads. The calculation of the air-ventilation energy demand according to EN 15251 is included respectively. Results offer effective methods for energy performance improvement in temperate climate conditions.

  6. 77 FR 43084 - Office of Federal High-Performance Green Buildings; Federal Buildings Personnel Training Act...

    Science.gov (United States)

    2012-07-23

    ... Federal High-Performance Green Buildings; Federal Buildings Personnel Training Act; Notification of... High- Performance Green Buildings, Office of Governmentwide Policy, General Services Administration... download from the Office of Federal High-Performance Green Building Web site Library at-- http://www.gsa...

  7. Financing medical office buildings.

    Science.gov (United States)

    Blake, J W

    1995-01-01

    This article discusses financing medical office buildings. In particular, financing and ownership options from a not-for-profit health care system perspective are reviewed, including use of tax-exempt debt, taxable debt, limited partnerships, sale, and real estate investment trusts (REITs).

  8. 2013 Building Technologies Office Program Peer Review Report

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2013-11-01

    The 2013 Building Technologies Office Program Peer Review Report summarizes the results of the 2013 Building Technologies Office (BTO) peer review, which was held in Washington, D.C., on April 2–4, 2013. The review was attended by over 300 participants and included presentations on 59 BTO-funded projects: 29 from BTO’s Emerging Technologies Program, 20 from the Commercial Buildings Integration Program, 6 from the Residential Buildings Integration Program, and 4 from the Building Energy Codes Program. This report summarizes the scores and comments provided by the independent reviewers for each project.

  9. Office Buildings: Assessing and Reducing Plug and Process Loads in Office Buildings (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2013-04-01

    Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly large fraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in office spaces are poorly understood.

  10. 2017 Building Technologies Office Peer Review Report

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2017-11-01

    The 2017 Building Technologies Office Peer Review Report summarizes the feedback submitted by reviewers for the 109 Building Technologies Office (BTO) projects presented at the 2017 BTO Peer Review. The report presents an overview of the goals and activities under each technology program area, a summary of project scores for each program, and a brief analysis of general evaluation trends within each program area or its constituent subprograms.

  11. Natural phenomena evaluation of the Department of Energy-field office Oak Ridge office buildings

    International Nuclear Information System (INIS)

    Rucker, R.W.; Fricke, K.E.; Hunt, R.J.

    1991-01-01

    The Department of Energy - Field Office Oak Ridge (DOE-OR) is performing natural phenomena evaluations of existing office buildings located in the city of Oak Ridge, Tennessee. The natural phenomena considered are earthquake, wind, and flood. The evaluations are being performed to determine if the facilities are in compliance with DOE General Design Criteria 6430.IA. This paper presents results of the evaluations for three of the office buildings

  12. 10 CFR 434.503 - Prototype building procedure.

    Science.gov (United States)

    2010-01-01

    .... For mixed-use buildings the Energy Cost Budget is derived by allocating the floor space of each...) Office (Business); (c) Retail (Mercantile); (d) Warehouse (Storage); (e) School (Educational); (f) Hotel...

  13. Lighting energy efficiency in office buildings: Sri Lanka

    International Nuclear Information System (INIS)

    Wijayatunga, Priyantha D.C.; Fernando, W.J.L.S.; Ranasinghe, S.

    2003-01-01

    This paper describes a study conducted in the lighting sector of office buildings as a part of a broader research study aimed at developing building codes for Sri Lanka addressing lighting as well as thermal comfort in order to optimise the use of electricity within these buildings. The study covered different tasks performed in office buildings and the optimum lighting levels required to perform these tasks in the office environment in Sri Lanka. Also, it included assessing the visual performance of people involved in different activities under varying illumination levels in a controlled environment and a comparison of these optimum lighting levels with international standards. It can be seen that the required optimum lighting levels are generally lower in Sri Lanka in comparison to specified standard levels, and this scenario is likely to be similar in other developing countries too. These findings clearly emphasise the need to adopt lighting standards most appropriate to local conditions, in turn helping improve the energy efficiency within buildings

  14. Building a parabolic solar concentrator prototype

    International Nuclear Information System (INIS)

    Escobar-Romero, J F M; Montiel, S Vazquez y; Granados-AgustIn, F; Rodriguez-Rivera, E; Martinez-Yanez, L; Cruz-Martinez, V M

    2011-01-01

    In order to not further degrade the environment, people have been seeking to replace non-renewable natural resources such as fossil fuels by developing technologies that are based on renewable resources. An example of these technologies is solar energy. In this paper, we show the building and test of a solar parabolic concentrator as a prototype for the production of steam that can be coupled to a turbine to generate electricity or a steam engine in any particular industrial process.

  15. Energy efficiency evaluation of hospital building office

    Science.gov (United States)

    Fitriani, Indah; Sangadji, Senot; Kristiawan, S. A.

    2017-01-01

    One of the strategy employed in building design is reducing energy consumption while maintaining the best comfort zone in building indoor climate. The first step to improve office buildings energy performance by evaluating its existing energy usage using energy consumption intensity (Intensitas Konsumsi Energi, IKE) index. Energy evaluation of office building for hospital dr. Sayidiman at Kabupaten Magetan has been carried out in the initial investigation. The office building is operated with active cooling (air conditioning, AC) and use limited daylighting which consumes 14.61 kWh/m2/month. This IKE value is attributed into a slightly inefficient category. Further investigation was carried out by modeling and simulating thermal energy load and room lighting in every building zone using of Ecotect from Autodesk. Three scenarios of building energy and lighting retrofit have been performed simulating representing energy efficiency using cross ventilation, room openings, and passive cooling. The results of the numerical simulation indicate that the third scenario by employing additional windows, reflector media and skylight exhibit the best result and in accordance with SNI 03-6575-2001 lighting standard. Total thermal load of the existing building which includes fabric gains, indirect solar gains, direct solar gains, ventilation fans, internal gains, inter-zonal gains and cooling load were 162,145.40 kWh. Based on the three scenarios, the thermal load value (kWh) obtained was lowest achieved scenario 2 with the thermal value of 117,539.08 kWh.The final results are interpreted from the total energy emissions evaluated using the Ecotect software, the heating and cooling demand value and specific design of the windows are important factors to determine the energy efficiency of the buildings.

  16. Energy efficiency evaluation of hospital building office

    International Nuclear Information System (INIS)

    Fitriani, Indah; Sangadji, Senot; Kristiawan, S.A.

    2017-01-01

    One of the strategy employed in building design is reducing energy consumption while maintaining the best comfort zone in building indoor climate. The first step to improve office buildings energy performance by evaluating its existing energy usage using energy consumption intensity (Intensitas Konsumsi Energi, IKE) index. Energy evaluation of office building for hospital dr. Sayidiman at Kabupaten Magetan has been carried out in the initial investigation. The office building is operated with active cooling (air conditioning, AC) and use limited daylighting which consumes 14.61 kWh/m2/month. This IKE value is attributed into a slightly inefficient category. Further investigation was carried out by modeling and simulating thermal energy load and room lighting in every building zone using of Ecotect from Autodesk. Three scenarios of building energy and lighting retrofit have been performed simulating representing energy efficiency using cross ventilation, room openings, and passive cooling. The results of the numerical simulation indicate that the third scenario by employing additional windows, reflector media and skylight exhibit the best result and in accordance with SNI 03-6575-2001 lighting standard. Total thermal load of the existing building which includes fabric gains, indirect solar gains, direct solar gains, ventilation fans, internal gains, inter-zonal gains and cooling load were 162,145.40 kWh. Based on the three scenarios, the thermal load value (kWh) obtained was lowest achieved scenario 2 with the thermal value of 117,539.08 kWh.The final results are interpreted from the total energy emissions evaluated using the Ecotect software, the heating and cooling demand value and specific design of the windows are important factors to determine the energy efficiency of the buildings. (paper)

  17. Radical Sustainable Innovation of office buildings

    DEFF Research Database (Denmark)

    Koch, Christian; Berker, Thomas; Koch-Ørvad, Nina

    2017-01-01

    by high degrees of newness in the entire life cycle. RSI should offer significant enhancements of known benefits, entirely new benefits, or substantial cost reductions, leading to the transformation of existing markets, the creation of sustainable growth, and global sustainability. Thus, if buildings were....../could be radically new. How to evaluate radicality is a major challenge. It is tentatively proposed, to use standards for sustainable office buildings. Standards are developed to accelerate the sustainable development but has to some extent come to constrain possibilities of radical innovation. As the criteria...... of newness is incorporated in standards, going beyond them, could be viewed as radical. Empirically a selection of international cases of office buildings with very high scores of BREEAM, LEED and DGNB are examined. Six selected cases were analysed more in detail, one of them, Geelens...

  18. Daylight utilisation in office buildings

    DEFF Research Database (Denmark)

    Christoffersen, Jens

    This Ph.D. thesis presents the qualitative and quantitative consequences of full-scale measurements on two daylighting systems, light shelf and Venetian blinds. The systems were investigated to assess their ability to increase daylight penetration and improve daylight distribution in the interior...... the benefits and difficulties regarding use of daylight in office buildings, but it is hoped that the report will provide daylight conscious building design in forthcoming non-domestic buil dings....

  19. Energy optimization of office buildings; Energioptimering af kontorbyggeri

    Energy Technology Data Exchange (ETDEWEB)

    Wittchen, K.B.; Place Hansen, E.J. de (Statens Byggeforskningsinstitut (SBi), Hoersholm (Denmark)); Radisch, N.H.; Treldal, J. (Ramboell A/S, Koebenhavn (Denmark))

    2011-07-01

    The project analysed two main office building types - high-rises and low-rises - and calculated a number of parameters, using the simulation program BSim. Calculations showed that the overall building design and orientation effect is moderate compared with, for instance, use of daylight control and low-energy lighting, computers, etc. Considerable energy savings can be achieved by use of natural ventilation in the summer, thus only using mechanical ventilation with heat recovery during the day in the winter. Open-plan offices result in a better indoor climate and lower energy consumption than cubicle offices. (LN)

  20. Advanced Energy Retrofit Guide Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Guopeng; Liu, Bing; Wang, Weimin; Zhang, Jian; Athalye, Rahul A.; Moser, Dave; Crowe, Eliot; Bengtson, Nick; Effinger, Mark; Webster, Lia; Hatten, Mike

    2011-09-27

    The Advanced Energy Retrofit Guide for Office Buildings is a component of the Department of Energy’s Advanced Energy Retrofit Guides for Existing Buildings series. The aim of the guides is to facilitate a rapid escalation in the number of energy efficiency projects in existing buildings and to enhance the quality and depth of those projects. By presenting general project planning guidance as well as financial payback metrics for the most common energy efficiency measures, these guides provide a practical roadmap to effectively planning and implementing performance improvements for existing buildings.

  1. Office worker response to an automated venetian blind and electric lighting system: A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Vine, E.; Lee, E.; Clear, R.; DiBartolomeo, D.; Selkowitz, S.

    1998-03-01

    A prototype integrated, dynamic building envelope and lighting system designed to optimize daylight admission and solar heat gain rejection on a real-time basis in a commercial office building is evaluated. Office worker response to the system and occupant-based modifications to the control system are investigated to determine if the design and operation of the prototype system can be improved. Key findings from the study are: (1) the prototype integrated envelope and lighting system is ready for field testing, (2) most office workers (N=14) were satisfied with the system, and (3) there were few complaints. Additional studies are needed to explain how illuminance distribution, lighting quality, and room design can affect workplans illuminance preferences.

  2. Active buildings: modelling physical activity and movement in office buildings. An observational study protocol.

    Science.gov (United States)

    Smith, Lee; Ucci, Marcella; Marmot, Alexi; Spinney, Richard; Laskowski, Marek; Sawyer, Alexia; Konstantatou, Marina; Hamer, Mark; Ambler, Gareth; Wardle, Jane; Fisher, Abigail

    2013-11-12

    Health benefits of regular participation in physical activity are well documented but population levels are low. Office layout, and in particular the number and location of office building destinations (eg, print and meeting rooms), may influence both walking time and characteristics of sitting time. No research to date has focused on the role that the layout of the indoor office environment plays in facilitating or inhibiting step counts and characteristics of sitting time. The primary aim of this study was to investigate associations between office layout and physical activity, as well as sitting time using objective measures. Active buildings is a unique collaboration between public health, built environment and computer science researchers. The study involves objective monitoring complemented by a larger questionnaire arm. UK office buildings will be selected based on a variety of features, including office floor area and number of occupants. Questionnaires will include items on standard demographics, well-being, physical activity behaviour and putative socioecological correlates of workplace physical activity. Based on survey responses, approximately 30 participants will be recruited from each building into the objective monitoring arm. Participants will wear accelerometers (to monitor physical activity and sitting inside and outside the office) and a novel tracking device will be placed in the office (to record participant location) for five consecutive days. Data will be analysed using regression analyses, as well as novel agent-based modelling techniques. The results of this study will be disseminated through peer-reviewed publications and scientific presentations. Ethical approval was obtained through the University College London Research Ethics Committee (Reference number 4400/001).

  3. The building of a prototype steering magnet

    International Nuclear Information System (INIS)

    Conradie, J.L.; Cornell, J.C.

    1983-01-01

    The report deals with the building of a prototype magnet. The magnet is completely symmetrical, and consists of 4 identical pieces of iron, 167 X 80 X 15 mm each. Magnetic flux density for 4 different magnet coils is given. Information is also given on the magnetic fields and the bending ability of the field through which the particles are supposed to move. The magnet coils and the form of the yoke are described

  4. The development of preliminary energy bench marking for office buildings in Malaysia

    International Nuclear Information System (INIS)

    Azah Ahmad; Asfaazam Kasbani

    2006-01-01

    Benchmarking energy consumption in buildings means comparing how much energy is used in a building to an average or theoretical standard relative to a set of similar buildings. Building energy benchmarking is a useful starting point for commercial building owners to target energy saving opportunities. Building owners can determine the energy performance efficiency level of their buildings and compare it to the entire group of office buildings of its class. It is also useful during the design stage of a new building or retrofit to determine if a design is relatively efficient. The energy performance of a building can be assessed using Building Energy Index (BEI) regardless of building's size, height or age. In the development of preliminary energy benchmarking for office buildings in Malaysia, Malaysia Energy Centre (PTM) has taken a step through its involvement with The Energy Efficiency and Conservation Network, via the Association of Southeast Asia Nations (ASEAN) Centre for Energy (ACE) through a project a develop a similar benchmarking system for various ASEAN members. Through data collection of 54 office building throughout Malaysia, preliminary or baseline energy consumption could be determined. This paper discusses the findings of current energy consumption of office buildings. I will also examine the overall trends of energy consumption among office buildings in Malaysia

  5. Wall envelopes in office buildings: design trend and implications on cooling load of buildings

    International Nuclear Information System (INIS)

    Ibrahim, N.; Ahmed, A.Z.; Ahmed, S.S.

    2006-01-01

    The wall envelope is a vital element of a building especially to a high rise building where its wall to building volume ratio is higher compared to other building forms. As well as a means of architectural expression, the wall envelope protects and regulates the indoor environment. In recent years there have been many applications of glass products and cladding systems in high-rise buildings built in Kuala Lumpur. This paper describes a recent research and survey on wall envelope designs adopted in 33 high-rise office buildings built in the central business district of Kuala Lumpur since 1990. This research adopts component design analysis to identify dominant trends on wall envelope design for the surveyed buildings. The paper seeks to discourse the implications of this design trend on energy consumption of high-rise office buildings in the country

  6. 78 FR 56703 - Office of Federal High-Performance Green Buildings; Green Building Advisory Committee...

    Science.gov (United States)

    2013-09-13

    ... Federal High-Performance Green Buildings; Green Building Advisory Committee; Notification of Upcoming... Green Building Advisory Committee Meeting (the Committee) and the schedule for a series of conference..., Designated Federal Officer, [[Page 56704

  7. Essential Approach of Maintenance Management System of Office Building

    Directory of Open Access Journals (Sweden)

    Masyatul Husna Othman

    2013-09-01

    Full Text Available Buildings will be worn-out, dilapidated and dirty as time goes by; but with good maintenance management we can at least prolong the lifespan of building longer as well as provide the building services and keep the building performance at it ultimate level. The importance of carrying out a systematic and routine maintenance works as part of works to conserve building performance is often neglected due to various factors including due to misunderstanding on the needs of the maintenance works itself and budget allocated. Thus, the purpose of the present study was to evaluating the level of maintenance management and quality of services in office buildings. This study also sought to answer the following question to determine the basic approach of maintenance management system used for office buildings.

  8. 77 FR 66616 - Office of Federal High-Performance Green Buildings; Green Building Advisory Committee...

    Science.gov (United States)

    2012-11-06

    ... Federal High-Performance Green Buildings; Green Building Advisory Committee; Notification of Upcoming... and agenda for the November 27, 2012, meeting of the Green Building Advisory Committee Meeting (the... Green Buildings, Office of Government-wide Policy, General Services Administration, 1275 First Street NE...

  9. 78 FR 21368 - Office of Federal High-Performance Green Buildings; Green Building Advisory Committee...

    Science.gov (United States)

    2013-04-10

    ... Federal High-Performance Green Buildings; Green Building Advisory Committee; Notification of Upcoming... and agenda for the May 1, 2013, meeting of the Green Building Advisory Committee Meeting (the... Green Buildings, Office of Government-wide Policy, General Services Administration, 1275 First Street NE...

  10. Investigation of Indoor Climate in a Naturally Ventilated Office Building

    DEFF Research Database (Denmark)

    Larsen, Tine Steen; Kalyanova, Olena; Jensen, Rasmus Lund

    2008-01-01

    A measuring program in a naturally ventilated office building in Copenhagen was carried out to document the indoor climate and ventilation system performance during a year. It included a questionnaire regarding the perceived indoor environmental quality and physical measurements of thermal comfort...... to a combination of poor control of solar shading and a very high local heat load that was above the Danish recommendations for naturally ventilated office buildings. Both measured and perceived indoor air quality in the building was in general very high. The measured air flow rates was relatively high due...... to the need for cooling in the office building, while the level of infiltration was quite low indicating an airtight construction....

  11. Assessment Framework of Building Facade in Optimizing Indoor Thermal Comfort of Green Building Index (GBI Certified Office Building

    Directory of Open Access Journals (Sweden)

    Abdul Tharim Asniza Hamimi

    2016-01-01

    Full Text Available During the past decade, the construction industry has seen a new trend in the development of “green” or “sustainable” construction concept around the world with vast support from prominent organization, together with the introduction of sustainable building codes. The establishment of green building certification systems worldwide is seen as one of the most efforts in the emerging green building movement. In order to support the development of the “green” and “sustainable” concept in Malaysia, Green Building Index (GBI was launched by the government on 21 May 2009 that created to promote sustainability in the built environment and raise awareness of environmental issues. However, the construction industry seems to have focused only on findings the “right mechanism” for an environmentally sustainable “final result” in order for the building to be certified as green with the lacking of continuous assessment on the building performance after the certifications. This study is purposely conducted to investigate the performance of various rated Green Building Index (GBI Non-Residential New Construction office buildings and the influence on Indoor Thermal Comfort (ITC of the selected buildings. The aim is to develop an assessment framework for optimum green building architectural façade to be used for office buildings in Malaysia as well as to analyse the occupants’ perception, satisfaction and performance in the selected Green Building Index (GBI rated office indoor environment. This research is still in its infancy; therefore the paper is focused on research aims, research scope and methodology, and expected deliverables for the proposed research.

  12. Energy-efficient and low CO{sub 2} office building

    Energy Technology Data Exchange (ETDEWEB)

    Airaksinen, M., Email: miimu.airaksinen@vtt.fi

    2012-06-15

    Current office buildings are becoming more and more energy efficient. In particular the importance of heating is decreasing, but the share of electricity use is increasing. When the CO{sub 2} equivalent emissions are considered, the emissions from embodied energy make up an important share of the total, indicating that the building materials have a high importance which is often ignored when only the energy efficiency of running the building is considered. This paper studies a new office building in design phase. The results showed that the reduction of energy use reduces both the primary energy use and CO{sub 2} eq. emissions. Especially the reduction of electricity use has a high importance for both primary energy use and CO{sub 2} emissions when fossil fuels are used. The lowest CO{sub 2} eq. emissions were achieved when bio-based, renewable energies or nuclear power was used to supply energy for the office building. Evidently then the share of CO{sub 2} eq. emissions from the embodied energy of building materials and products became the dominant source of CO{sub 2} eq. emissions. (orig.)

  13. Building Green: The Adoption Process of LEED- and Energy Star-Rated Office Buildings

    Science.gov (United States)

    Malkani, Arvin P.

    2012-01-01

    There are opportunities for green building technology in office buildings to produce energy savings and cost efficiencies that can produce a positive economic and environmental impact. In order for these opportunities to be realized, however, decision makers must appreciate the value of green building technology. The objective of this research is…

  14. 77 FR 2296 - Office of Federal High-Performance Green Buildings; the Green Building Advisory Committee...

    Science.gov (United States)

    2012-01-17

    ... Federal High-Performance Green Buildings; the Green Building Advisory Committee; Notification of Upcoming... teleconference meetings of the Green Building Advisory Committee (the Committee). The teleconference meetings are... Federal High Performance Green Buildings, Office of Governmentwide Policy, General Services Administration...

  15. Relationship between Quality of Building Maintenance System and Occupant Satisfaction for Office Buildings

    Directory of Open Access Journals (Sweden)

    Hamid A.H.A

    2014-03-01

    Full Text Available Buildings will be weary, decaying and dirty as time goes by; but with highquality maintenance management we can prolong the life-span of building, provide building services and keep the building performance at its ultimate level. The importance of carrying out a systematic and routine maintenance is to conserve building performance. However, this task is often neglected due to various factors including misunderstanding the needs of the maintenance works and lack of budget allocation. This paper highlights the current practice of maintenance management that are being implemented in 6 office buildings located in Kuala Lumpur, Johor, Kedah and Pulau Pinang. Using the responses of questionnaire answered by 150 respondents employed from these selected offices, personal interviews and visual inspection the following findings were made: the occupants were satisfied with the maintenance management of their buildings elements and the delivery characteristics of maintenance works. Visual inspection however showed that some elements are not in a good condition. In conclusion, some recommendations are made to improve the existing system including the establishment of a maintenance plan, selection of experienced contractors and the provision of a service desk.

  16. Environmental satisfaction in multi-tenant office buildings : a holistic approach

    NARCIS (Netherlands)

    Rovers, N.; Appel - Meulenbroek, H.A.J.A.; Kemperman, A.D.A.M.; Appel-Meulenbroek, R.; Jylhä, T.

    2017-01-01

    PurposeIn the current office market office providers are obligated to meet as many wishes of the (future) tenants and end-users of their buildings as possible in order to keep their buildings from becoming vacant. In order to do so it is necessary to gain more insight in these wishes. The aim of

  17. Decision-making aids for the rational use of energy in office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Daniels, K [HL-Technik G.m.b.H., Muenchen (Germany, F.R.)

    1979-11-01

    The rational use of energy in office buildings can be assured by intensifying cooperation between owner, architect, structural designer, and installer with a view to the employment of technical aids and the interdependence of design concept and structural configuration. As can be seen from a comparison of different types of buildings, there are considerable differences in the anticipated energy consumption and the potential use of energy. It is important to note that continued serviceability of an office building must be assured at times of crisis when only a minimum of energy is available and that modern office buildings are so supplied with utilities that energy is only used if this is required for comfort and office work.

  18. Building-related risk factors and work-related lower respiratory symptoms in 80 office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, M.J.; Naco, G.M.; Wilcox, T.G.; Sieber, W.K.

    2002-01-01

    We assessed building-related risk factors for lower respiratory symptoms in office workers. The National Institute for Occupational Safety and Health in 1993 collected data during indoor environmental health investigations of workplaces. We used multivariate logistic regression analyses to assess relationships between lower respiratory symptoms in office workers and risk factors plausibly related to microbiologic contamination. Among 2,435 occupants in 80 office buildings, frequent, work-related multiple lower respiratory symptoms were strongly associated, in multivariate models, with two risk factors for microbiologic contamination: poor pan drainage under cooling coils and debris in outside air intake. Associations tended to be stronger among those with a history of physician-diagnosed asthma. These findings suggest that adverse lower respiratory health effects from indoor work environments, although unusual, may occur in relation to poorly designed or maintained ventilation systems, particularly among previously diagnosed asthmatics. These findings require confirmation in more representative buildings.

  19. Building-related risk factors and work-related lower respiratory symptoms in 80 office buildings

    International Nuclear Information System (INIS)

    Mendell, M.J.; Naco, G.M.; Wilcox, T.G.; Sieber, W.K.

    2002-01-01

    We assessed building-related risk factors for lower respiratory symptoms in office workers. The National Institute for Occupational Safety and Health in 1993 collected data during indoor environmental health investigations of workplaces. We used multivariate logistic regression analyses to assess relationships between lower respiratory symptoms in office workers and risk factors plausibly related to microbiologic contamination. Among 2,435 occupants in 80 office buildings, frequent, work-related multiple lower respiratory symptoms were strongly associated, in multivariate models, with two risk factors for microbiologic contamination: poor pan drainage under cooling coils and debris in outside air intake. Associations tended to be stronger among those with a history of physician-diagnosed asthma. These findings suggest that adverse lower respiratory health effects from indoor work environments, although unusual, may occur in relation to poorly designed or maintained ventilation systems, particularly among previously diagnosed asthmatics. These findings require confirmation in more representative buildings

  20. Pre study. Prototype of CO2 heat pump system for heating and cooling of a larger building

    International Nuclear Information System (INIS)

    Stene, Joern; Jakobsen, Arne

    2006-03-01

    The activities concerning CO 2 heat pumps during NTNU-SINTEF's strategic research program SMARTBYGG (2002-2006) has lead to an increased interest in planning, building, installing and testing a prototype CO 2 heat pump for heating and cooling of a larger building. In cooperation with Statsbygg and Naeringslivets Idefond a p restudy was initiated in 2005, with the main aim to carry out a set of defined activities, preparing the ground for the realization of a prototype. The following subjects are treated in the p restudy: a technological assessment of the CO 2 heat pumps, a technological assessment of the interaction between the CO 2 heat pump and the secondary systems, a study of the possibilities regarding suitable CO 2 components including compressors, heat exchangers, valves etc., and a presentation of Teknotherm AS (Halden), a Norwegian industrial partner that can project, build and maintain a CO 2 heat pump prototype. During the project period Statsbygg has not found a suitable building where a prototype can be installed. It is recommended that further work is made on the realization of a CO 2 prototype plant by setting up a main project (ml)

  1. Low-energy office buildings using existing technology. Simulations with low internal heat gains

    Energy Technology Data Exchange (ETDEWEB)

    Flodberg, Kajsa; Blomsterberg, Aake; Dubois, Marie-Claude [Lund Univ. (Sweden). Div. of Energy and Building Design

    2012-11-01

    Although low-energy and nearly zero-energy residential houses have been built in Sweden in the past decade, there are very few examples of low-energy office buildings. This paper investigates the design features affecting energy use in office buildings and suggests the optimal low-energy design from a Swedish perspective. Dynamic simulations have been carried out with IDA ICE 4 on a typical narrow office building with perimeter cell rooms. The results from the parametric study reveal that the most important design features for energy saving are demand-controlled ventilation as well as limited glazing on the facade. Further energy-saving features are efficient lighting and office equipment which strongly reduce user-related electricity and cooling energy. Together, the simulation results suggest that about 48% energy can be saved compared to a new office building built according to the Swedish building code. Thus, it is possible, using a combination of simple and well-known building technologies and configurations, to have very low energy use in new office buildings. If renewable energy sources, such as solar energy and wind power, are added, there is a potential for the annual energy production to exceed the annual energy consumption and a net zero-energy building can be reached. One aspect of the results concerns user-related electricity, which becomes a major energy post in very low-energy offices and which is rarely regulated in building codes today. This results not only in high electricity use, but also in large internal heat gains and unnecessary high cooling loads given the high latitude and cold climate. (orig.)

  2. 76 FR 35894 - Office of Federal High-Performance Green Buildings; Establishment of the Green Building Advisory...

    Science.gov (United States)

    2011-06-20

    ... Federal High-Performance Green Buildings; Establishment of the Green Building Advisory Committee AGENCY... announces the establishment of the Green Building Advisory Committee (the Committee), pursuant to Section... strategic plans, products and activities of the Office of Federal High-Performance Green Buildings and...

  3. Building an evolvable prototype for a multiple GAAP accounting information system

    NARCIS (Netherlands)

    Vanhoof, E.; De Bruyn, P.; Aerts, Walter; Verelst, J.; Aveiro, D.; Pergl, R.; Gouveia, D.

    In this paper we build a prototype of an evolvable Accounting Information System (AIS) that supports multiple Generally Accepted Accounting Standards (GAAP) reporting. Reporting in multiple GAAP can have different origins: differences in local and tax GAAP, belonging to an economic group or

  4. Designing of zero energy office buildings in hot arid climate

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Gwad, Mohamed

    2011-07-01

    The designing of office buildings by using large glass areas to have a transparent building is an attractive approach in the modern office building architecture. This attitude increases the energy demand for cooling specially in the hot arid region which has long sun duration time, while the use of small glazing areas increases the energy demand for lighting. The use of uncontrolled natural ventilation increases the rate of hot ambient air flow which increases the building energy demand for cooling. At the same time, the use of mechanical ventilation to control the air change rate may increase the energy demand for fans. Some ideas such as low energy design concept are introduced for improving the building energy performance and different rating systems have been developed such as LEED, BREEAM and DGNB for evaluating building energy performance system. One of the new ideas for decreasing the dependence on fossil fuels and improving the use of renewable energy is the net zero-energy building concept in which the building generates enough renewable energy on site to equal or exceed its annual energy use. This work depends on using the potentials of mixing different energy strategies such as hybrid ventilation strategy, passive night cooling, passive chilled ceiling side by side with the integrating of photovoltaic modules into the building facade to produce energy and enrich the architectural aesthetics and finally reaching the Net Zero Energy Building. There are different definitions for zero energy buildings, however in this work the use of building-integrated Photovoltaic (BIPV) to provide the building with its annual energy needs is adopted, in order to reach to a Grid-Connected Net-Zero Energy Office Building in the hot arid desert zone represented by Cairo, Egypt. (orig.)

  5. Solar shading control strategy for office buildings in cold climate

    DEFF Research Database (Denmark)

    Røseth Karlsen, Line; Heiselberg, Per Kvols; Bryn, Ida

    2016-01-01

    Highlights •Solar shading control strategy for office buildings in cold climate is developed. •Satisfying energy and indoor environmental performance is confirmed. •Importance of integrated evaluations when selecting shading strategy is illustrated.......Highlights •Solar shading control strategy for office buildings in cold climate is developed. •Satisfying energy and indoor environmental performance is confirmed. •Importance of integrated evaluations when selecting shading strategy is illustrated....

  6. Study and constructive analysis of an office building

    OpenAIRE

    CORT AZCÁRRAGA, PAULA

    2015-01-01

    [EN] The development is based on the study and analysis of an office building located in Drongsesteenweg, Gent 9000. The building has 4 levels and basement. The structure is with prefabricated concrete, a very typical way to build in Belgium, only the basement was built in situ. Typology floor is hollow core slab, it is a prefabricated unidirectional floor. Stairs are prefabricated too, executed by a company specialized in this type works. To the facade they use two types of bricks, ceramic a...

  7. Office Building, Roskilde, Denmark. Parkvænget 25, 4000 Roskilde

    DEFF Research Database (Denmark)

    Rose, Jørgen; Thomsen, Kirsten Engelund

    Built in 1968 the office building was a typical precast concrete building with a very limited level of insulation. In 1991 the building envelope was renovated and insulation was added to the wall (175 mm) and windows were replaced with traditional double-glazed windows. The main objective...

  8. Suitability assessment of building energy saving technologies for office buildings in cold areas of China based on an assessment framework

    International Nuclear Information System (INIS)

    Geng, Geng; Wang, Zhaoxia; Zhao, Jing; Zhu, Neng

    2015-01-01

    Highlights: • An assessment method considering economy, environment and technology is proposed. • Office buildings are classified into 3 types and weights are calculated respectively. • BESTs were summed up as 3 suitability levels. • Recommendations are proposed for adopting in design stage. - Abstract: Blind application and extensive copy of building energy saving technologies have been found very common through investigation in China. Emphases should be put on the suitability assessment when selecting and optimizing building energy saving technologies. This paper created an assessment method, namely an assessment framework to assess the suitability level of building energy saving technologies from a holistic point of view. Fuzzy analytic hierarchy process was adopted. 3 factors and 8 sub-factors were included in the framework. The office buildings were classified into 3 types to calculate weights of factors and sub-factors. The assessment framework was established for each type of office buildings. 20 energy saving technologies from surveyed cases was selected as case study. Ranks of suitability level of the assessment objects were obtained for each type of office buildings. The assessment results could be referred when selecting building energy saving technologies in the design stage

  9. Best Practices Guide for High-Performance Indian Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Reshma [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sartor, Dale [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Ghatikar, Girish [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-04-01

    This document provides best practice guidance and energy- efficiency recommendations for the design, construction, and operation of high-­performance office buildings in India. Through a discussion of learnings from exemplary projects and inputs from experts, it provides recommendations that can potentially help achieve (1) enhanced working environments, (2) economic construction/faster payback, (3) reduced operating costs, and (4) reduced greenhouse gas (GHG) emissions. It also provides ambitious (but achievable) energy performance benchmarks, both as adopted targets during building modeling (design phase) and during measurement and verification (operations phase). These benchmarks have been derived from a set of representative best-in-class office buildings in India. The best practices strategies presented in this guide would ideally help in delivering high-­performance in terms of a triad—of energy efficiency, cost efficiency, and occupant comfort and well-­being. These best practices strategies and metrics should be normalized—that is, corrected to account for building characteristics, diversity of operations, weather, and materials and construction methods.

  10. Building spatial layout that supports healthier behavior of office workers: a new performance mandate for sustainable buildings.

    Science.gov (United States)

    Hua, Ying; Yang, Eunhwa

    2014-01-01

    The pursuit of efficiency and the permeation of communication technologies in modern workplace have increased prolonged sitting and physical inactivity among the white-collar workforce. Physical inactivity is a major risk factor for developing various chronic diseases and obesity. This study intends to understand the impact of physical environment on both voluntary and imperative physical activity levels in an office building, and to collect evidence for design suggestions to encourage office workers' activity level on a daily basis. This study examined how proximity from individual workstations to various shared service and amenity spaces in the workplace (e.g., meeting spaces, copy areas, kitchens, restrooms, elevators, and stairs) is associated with office workers' physical activity level (e.g., sedentary and non-sedentary behavior) and their environmental and job satisfaction. To objectively measure physical activity, twenty-six office workers, in a three-story office building, wore accelerometers for three consecutive days at work. Environmental and job satisfaction of office workers was measured by a questionnaire. Proximity variables were measured using the floor plans of the subject building. Participants on average were sedentary for 80% of the time during the study. Proximity to several service and amenity areas was positively associated with step counts and job satisfaction.

  11. Intelligent Facades in Buildings Facades of local Office Buildings - Case Study

    Directory of Open Access Journals (Sweden)

    Al-Qaraghuli Anwar Subhi

    2016-01-01

    Full Text Available In order to meet the functional performance and requirements on the environmental, ecological, social and aesthetical aspects, it became a necessity to develop another options of building that would be more efficient in the provision of those requirements, so a new generation have appeared called “Smart Buildings” or “Intelligent Buildings” with their sophisticated parts and various details, one of those essential parts is the “Intelligent Façade” for it’s being the essential and primary defensive line for the building against the environmental and climatic variations.This research focused on presenting the most clearly and comprehensive perception of the intelligent façades, in a manner that serves the ability of the designer to apply them in his designs or while developing an existing façades in local (Iraqi office buildings.To achieve such goal, it has been a necessity to adopt a descriptive and analytical Method for the previous knowledge and take a sequential researching steps, the first step was to build a comprehensive theoretical framework by defining the intelligent façade. Down to abstracting three main vocabularies of the theoretical framework represented by: integrated intelligent façade design, intelligent façade techniques, and effective response.The next research steps focused on applying the vocabularies of the theoretical framework on the elected local office buildings that have been adopted the matter of intelligent façades in one of their forms, and then analyze/discuss the results of the applicable study, to be able to draw the final conclusions, and by this the research presented a determined recommendations.

  12. Prototyping Practice

    DEFF Research Database (Denmark)

    Ramsgaard Thomsen, Mette; Tamke, Martin

    2015-01-01

    This paper examines the role of the prototyping in digital architecture. During the past decade, a new research field has emerged exploring the digital technology’s impact on the way we think, design and build our environment. In this practice the prototype, the pavilion, installation or demonstr......This paper examines the role of the prototyping in digital architecture. During the past decade, a new research field has emerged exploring the digital technology’s impact on the way we think, design and build our environment. In this practice the prototype, the pavilion, installation...

  13. 49 CFR 1242.21 - Station and office buildings (account XX-19-23).

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 9 2010-10-01 2010-10-01 false Station and office buildings (account XX-19-23). 1242.21 Section 1242.21 Transportation Other Regulations Relating to Transportation (Continued) SURFACE... Structures § 1242.21 Station and office buildings (account XX-19-23). If the sum of the direct freight and...

  14. Perceived air quality and sensory pollution loads in six Danish office buildings

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Krupicz, P.; Szczecinski, A.

    2002-01-01

    Perceived air quality and sensory pollution loads were measured in 6 office buildings with mechanical ventilation without recirculation, in each buildings in 6 representative non-smoking medium-sized and small offices with mixing ventilation. An untrained panel of 43 subjects assessed the air...... quality on a normal weekday when the building was occupied, and on a weekend without occupants in the building. On both occasions the ventilation system was in operation as on a normal working day. Outdoor air supply rate, air temperature, relative humidity, concentration of carbon dioxide and ultrafine...

  15. Workplace building design and office-based workers' activity: a study of a natural experiment.

    Science.gov (United States)

    Jancey, Jonine M; McGann, Sarah; Creagh, Robyn; Blackford, Krysten D; Howat, Peter; Tye, Marian

    2016-02-01

    This opportunistic natural study investigated the effects of relocation of office workers from a 30-year-old building to a new purpose-built building. The new building included an attractive central staircase that was easily accessed and negotiated, as well as breakout spaces and a centralised facilities area. The researchers aimed to determine the impact of the purpose-built office building on the office workers' sedentariness and level of physical activity. In 2013, a natural pre-post study was undertaken with office-based workers in their old conventional 1970s building and on relocating to a new purpose-built 'activity permissive' building. Objective movement data was measured using accelerometers. Anthropometric and demographic data was also collected. Forty-two office-based workers significantly decreased their percentage of daily sitting time (T1 = 84.9% to T2=79.7%; pbuilding. Moderate activity significantly declined (T1=3.9% to 3.2%=T2; p=0.038). There was a significant decrease in mean minutes of sitting time (19.62 minutes; pbuilding can influence activity. This opportunistic study on the impact of workplace relocation on office-based workers' activity showed modest positive outcomes in sitting and standing. Evidence is required to inform building design policy and practice that supports physical activity and reduces levels of sedentariness in the workplace. © 2015 The Authors.

  16. Spatial and temporal variation of particulate matter characteristics within office buildings - The OFFICAIR study.

    Science.gov (United States)

    Szigeti, Tamás; Dunster, Christina; Cattaneo, Andrea; Spinazzè, Andrea; Mandin, Corinne; Le Ponner, Eline; de Oliveira Fernandes, Eduardo; Ventura, Gabriela; Saraga, Dikaia E; Sakellaris, Ioannis A; de Kluizenaar, Yvonne; Cornelissen, Eric; Bartzis, John G; Kelly, Frank J

    2017-06-01

    In the frame of the OFFICAIR project, office buildings were investigated across Europe to assess how the office workers are exposed to different particulate matter (PM) characteristics (i.e. PM 2.5 mass concentration, particulate oxidative potential (OP) based on ascorbate and reduced glutathione depletion, trace element concentration and total particle number concentration (PNC)) within the buildings. Two offices per building were investigated during the working hours (5 consecutive days; 8h per day) in two campaigns. Differences were observed for all parameters across the office buildings. Our results indicate that the monitoring of the PM 2.5 mass concentration in different offices within a building might not reflect the spatial variation of the health relevant PM characteristics such as particulate OP or the concentration of certain trace elements (e.g., Cu, Fe), since larger differences were apparent within a building for these parameters compared to that obtained for the PM 2.5 mass concentration in many cases. The temporal variation was larger for almost all PM characteristics (except for the concentration of Mn) than the spatial differences within the office buildings. These findings indicate that repeated or long-term monitoring campaigns are necessary to have information about the temporal variation of the PM characteristics. However, spatial variation in exposure levels within an office building may cause substantial differences in total exposure in the long term. We did not find strong associations between the investigated indoor activities such as printing or windows opening and the PNC values. This might be caused by the large number of factors affecting PNC indoors and outdoors. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Benchmarking the energy performance of office buildings: A data envelopment analysis approach

    Directory of Open Access Journals (Sweden)

    Molinos-Senante, María

    2016-12-01

    Full Text Available The achievement of energy efficiency in buildings is an important challenge facing both developed and developing countries. Very few papers have assessed the energy efficiency of office buildings using real data. To overcome this limitation, this paper proposes an energy efficiency index for buildings having a large window-to-wall ratio, and uses this index to identify the main architectural factors affecting energy performance. This paper assesses, for the first time, the energy performances of 34 office buildings in Santiago, Chile, by using data envelopment analysis. Overall energy efficiency is decomposed into two indices: the architectural energy efficiency index, and the management energy efficiency index. This decomposition is an essential step in identifying the main drivers of energy inefficiency and designing measures for improvement. Office buildings examined here have significant room for improving their energy efficiencies, saving operational costs and reducing greenhouse gas emissions. The methodology and results of this study will be of great interest to building managers and policymakers seeking to increase the sustainability of cities.

  18. Efficient utilization of energy in office buildings. Planning manual; Effiziente Energienutzung in Buerogebaeuden. Planungsleitfaden

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-15

    Regarding to the energy efficiency of office buildings, a high standard is set to architects: Office buildings need more energy for the cooling in the summer than for the heating in the winter. Additionally, there is an energy consumption for lighting, ventilation and operation of office equipment. Under this aspect, in the planning manual under consideration ten demands for an efficient energy utilization at office buildings are described: (a) Integral concept for the minimization of the entire power demand; (b) Compact building method and very good structural thermal protection; (c) Adapted glass areas and quality of vitrifications; (d) Integrals ventilation planning; (e) Efficient ventilation systems; (f) Efficient room climate concept and minimization of internal and outside heat loads; (g) Utilization of daylight with adapted architectural draft; (h) Efficient artificial lighting; (i) Supply of warmth and coldness with minimum characteristic values for primary energy; (j) Energy monitoring and optimization of operation. This manual also is valid for other buildings such as schools, administration buildings or swimming pools.

  19. Ergonomics evaluation of a government office building.

    Science.gov (United States)

    Pentikis, John; Lopez, Mary S; Thomas, Robert E

    2002-01-01

    An ergonomics team from the US Army Center for Health Promotion and Preventive medicine evaluated 465 video display terminal (VDT) workstations in a Government office building over an 18-day period. Each workstation evaluation involved an assessment of the worker, the chair, the desk, the keyboard, the pointing device, the monitor, and the office environmental conditions. The team also collected worker pain and injury information. The problems seen during the evaluation were characteristic of most office environments where VDT workstation furniture was purchased before the advent of mouse-driven software. The majority of furniture evaluated was not designed to meet the demands of intensive mouse use for prolonged periods of time. Much of the workstation furniture was not adjustable, chairs lacked adequate back support, and workers assumed non-neutral postures. As a result, more than 35% of the workers evaluated complained of on-the-job pain. New office furniture that is adjustable, adequate desk space and storage space were among the solutions recommended by the ergonomics team.

  20. Solar Shading in Low Energy Office Buildings - Design Strategy and User Perception

    Directory of Open Access Journals (Sweden)

    Steinar Grynning

    2017-06-01

    Full Text Available The objective of this paper is to investigate the visual comfort and quality of daylight in modern office buildings in the Nordic climate. A study of various daylight-related aspects and qualities was carried out for three different office buildings, using a combination of quantitative and qualitative methods. The focus was on a combination of user perception of daylight quality and assessment of the daylight amount and quality, by using the daylight factor (DF and useful daylight illuminance parameters. Previous studies and experiences from construction examples indicate that users, in general, complain about lack of manual control of systems and too low daylight levels, even if the requirements in the building codes are satisfied. Furthermore, they complain about control algorithms of the shading devices, which cause undesired automatic opening and closure of such devices. Thus, causing disturbances and irritation amongst the users. Hence, interviews with key personnel in a modern and architecturally acclaimed office building were carried out in addition to an in-depth analysis of previous surveys of a zero-energy office building. It was found that automatic moveable shading can be regarded as a source of discomfort. This is due to the lack of manual-control override possibilities, which causes disturbances due to the system moving up and down. In one of the offices, the users disabled the exterior shading system. However, the external fixed shading and the internal manually operated roller blinds were found to be satisfactory. The results from a previous study showed that the users in the Marche building are in general satisfied with the daylight. One of the main reasons for this, according to the users, is that they have manual control of the shading system. Manual control of the shading systems is preferred by users in the office buildings studied. Daylight simulations showed that the external fixed shading system combined with internal

  1. Technical Support Document: 50% Energy Savings Design Technology Packages for Medium Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, Brian A.; Wang, Weimin; Lane, Michael D.; Rosenberg, Michael I.; Liu, Bing

    2009-09-01

    This Technical Support Document (TSD) describes the process and methodology for development of the Advanced Energy Design Guide for Medium Offices (AEDG-MO or the Guide), a design guidance document which intends to provide recommendations for achieving 50% energy savings in medium office buildings that just meet the requirements of ANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings.

  2. Simulation of temperature in office with building integrated heating and cooling system

    DEFF Research Database (Denmark)

    Weitzmann, Peter

    2002-01-01

    In this paper a numerical investigation of the thermal indoor environment has been performed for an office with building integrated hydronic heating and cooling system. Today office buildings are designed in such a way, and have such high internal heat loads and solar gains, that some kind...... of cooling is normally necessary for most of the year. Even in as cool climates as in the Nordic countries. The way the cooling is often achieved is through air conditioning. This can in many cases lead to sick building syndrome (SBS) symptoms, and furthermore it results in high energy consumption periods...... the temperature of the concrete to a level slightly below the desired room temperature, the concrete will work as an absorber for the excess heat in the office. This can significantly reduce the need for air conditioning, which will give both improved indoor climate and lower energy costs in the building...

  3. Façade system for existing office buildings in Copenhagen

    DEFF Research Database (Denmark)

    Hannoudi, Loay Akram; Christensen, Jørgen Erik; Lauring, Michael

    2015-01-01

    This study investigates solutions for facade renovation of general office buildings built between 1960 and 1980 in the Copenhagen Municipality. 44 buildings are used for the study. They share common structural and construction principles like the use of beams and columns and prefabricated elements...

  4. A new life : Transformation of vacant office buildings into housing

    NARCIS (Netherlands)

    Remøy, HT; van der Voordt, Theo; Haugen, Tore I.; Moum, Anita; Brochner, Jan

    2006-01-01

    Office buildings are experiencing vacancy. This leads to financial problems for the owners and social problems for the community, e.g. vandalism and deterioration. A solution may be found in transformation of vacant buildings and changing the buildings’ program. In the Dutch situation, housing is a

  5. Energy consumption in office buildings. Trends and drivers; Energibruk i kontorbygg. Trender og drivere

    Energy Technology Data Exchange (ETDEWEB)

    Langseth, Benedicte

    2013-02-01

    This report focuses on the energy usage of Norwegian office buildings. Historic data on the subject is limited, so qualitative input is gathered through interviews with property owners and contractors for energy solutions. We have looked at what affects the total area of office buildings in Norway, and realized that it more or less follows the inland gross domestic product. The report also includes cross-sectional analyses from various data sources to find what affects the specific energy usage of office buildings. The actual measured consumption deviates from estimated consumption, especially in newer buildings and especially within ventilation and cooling. Additionally, a model has been developed for projective purposes. It is well suited to test the effect of various input parameters and assumptions on the total area of office buildings and their energy consumption. Though as of yet the quality of data is not good enough to make a profound and credible estimate of total energy usage.(eb)

  6. An Adaptive Intelligent Integrated Lighting Control Approach for High-Performance Office Buildings

    Science.gov (United States)

    Karizi, Nasim

    An acute and crucial societal problem is the energy consumed in existing commercial buildings. There are 1.5 million commercial buildings in the U.S. with only about 3% being built each year. Hence, existing buildings need to be properly operated and maintained for several decades. Application of integrated centralized control systems in buildings could lead to more than 50% energy savings. This research work demonstrates an innovative adaptive integrated lighting control approach which could achieve significant energy savings and increase indoor comfort in high performance office buildings. In the first phase of the study, a predictive algorithm was developed and validated through experiments in an actual test room. The objective was to regulate daylight on a specified work plane by controlling the blind slat angles. Furthermore, a sensor-based integrated adaptive lighting controller was designed in Simulink which included an innovative sensor optimization approach based on genetic algorithm to minimize the number of sensors and efficiently place them in the office. The controller was designed based on simple integral controllers. The objective of developed control algorithm was to improve the illuminance situation in the office through controlling the daylight and electrical lighting. To evaluate the performance of the system, the controller was applied on experimental office model in Lee et al.'s research study in 1998. The result of the developed control approach indicate a significantly improvement in lighting situation and 1-23% and 50-78% monthly electrical energy savings in the office model, compared to two static strategies when the blinds were left open and closed during the whole year respectively.

  7. A generalized window energy rating system for typical office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Cheng; Chen, Tingyao; Yang, Hongxing; Chung, Tse-ming [Research Center for Building Environmental Engineering, Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong (China)

    2010-07-15

    Detailed computer simulation programs require lengthy inputs, and cannot directly provide an insight to relationship between the window energy performance and the key window design parameters. Hence, several window energy rating systems (WERS) for residential houses and small buildings have been developed in different countries. Many studies showed that utilization of daylight through elaborate design and operation of windows leads to significant energy savings in both cooling and lighting in office buildings. However, the current WERSs do not consider daylighting effect, while most of daylighting analyses do not take into account the influence of convective and infiltration heat gains. Therefore, a generalized WERS for typical office buildings has been presented, which takes all primary influence factors into account. The model includes embodied and operation energy uses and savings by a window to fully reflect interactions among the influence parameters. Reference locations selected for artificial lighting and glare control in the current common simulation practice may cause uncompromised conflicts, which could result in over- or under-estimated energy performance. Widely used computer programs, DOE2 and ADELINE, for hourly daylighting and cooling simulations have their own weaknesses, which may result in unrealistic or inaccurate results. An approach is also presented for taking the advantages of the both programs and avoiding their weaknesses. The model and approach have been applied to a typical office building of Hong Kong as an example to demonstrate how a WERS in a particular location can be established and how well the model can work. The energy effect of window properties, window-to-wall ratio (WWR), building orientation and lighting control strategies have been analyzed, and can be indicated by the localized WERS. An application example also demonstrates that the algebraic WERS derived from simulation results can be easily used for the optimal design of

  8. Implementing effect of energy efficiency supervision system for government office buildings and large-scale public buildings in China

    International Nuclear Information System (INIS)

    Zhao Jing; Wu Yong; Zhu Neng

    2009-01-01

    The Chinese central government released a document to initiate a task of energy efficiency supervision system construction for government office buildings and large-scale public buildings in 2007, which marks the overall start of existing buildings energy efficiency management in China with the government office buildings and large-scale public buildings as a breakthrough. This paper focused on the implementing effect in the demonstration region all over China for less than one year, firstly introduced the target and path of energy efficiency supervision system, then described the achievements and problems during the implementing process in the first demonstration provinces and cities. A certain data from the energy efficiency public notice in some typical demonstration provinces and cities were analyzed statistically. It can be concluded that different functional buildings have different energy consumption and the average energy consumption of large-scale public buildings is too high in China compared with the common public buildings and residential buildings. The obstacles need to be overcome afterward were summarized and the prospects for the future work were also put forward in the end.

  9. Implementing effect of energy efficiency supervision system for government office buildings and large-scale public buildings in China

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Jing [School of Environmental Science and Engineering, Tianjin University, Tianjin 300072 (China)], E-mail: zhaojing@tju.edu.cn; Wu Yong [Department of Science and Technology, Ministry of Housing and Urban-Rural Development of the People' s Republic of China, Beijing 100835 (China); Zhu Neng [School of Environmental Science and Engineering, Tianjin University, Tianjin 300072 (China)

    2009-06-15

    The Chinese central government released a document to initiate a task of energy efficiency supervision system construction for government office buildings and large-scale public buildings in 2007, which marks the overall start of existing buildings energy efficiency management in China with the government office buildings and large-scale public buildings as a breakthrough. This paper focused on the implementing effect in the demonstration region all over China for less than one year, firstly introduced the target and path of energy efficiency supervision system, then described the achievements and problems during the implementing process in the first demonstration provinces and cities. A certain data from the energy efficiency public notice in some typical demonstration provinces and cities were analyzed statistically. It can be concluded that different functional buildings have different energy consumption and the average energy consumption of large-scale public buildings is too high in China compared with the common public buildings and residential buildings. The obstacles need to be overcome afterward were summarized and the prospects for the future work were also put forward in the end.

  10. Implementing effect of energy efficiency supervision system for government office buildings and large-scale public buildings in China

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Jing; Zhu, Neng [School of Environmental Science and Engineering, Tianjin University, Tianjin 300072 (China); Wu, Yong [Department of Science and Technology, Ministry of Housing and Urban-Rural Development of the People' s Republic of China, Beijing 100835 (China)

    2009-06-15

    The Chinese central government released a document to initiate a task of energy efficiency supervision system construction for government office buildings and large-scale public buildings in 2007, which marks the overall start of existing buildings energy efficiency management in China with the government office buildings and large-scale public buildings as a breakthrough. This paper focused on the implementing effect in the demonstration region all over China for less than one year, firstly introduced the target and path of energy efficiency supervision system, then described the achievements and problems during the implementing process in the first demonstration provinces and cities. A certain data from the energy efficiency public notice in some typical demonstration provinces and cities were analyzed statistically. It can be concluded that different functional buildings have different energy consumption and the average energy consumption of large-scale public buildings is too high in China compared with the common public buildings and residential buildings. The obstacles need to be overcome afterward were summarized and the prospects for the future work were also put forward in the end. (author)

  11. Hybrid Ventilation in New and Retrofitted Office Buildings

    DEFF Research Database (Denmark)

    Heiselberg, Per

    The scope of this annex is to obtain better knowledge of the use of hybrid ventilation technologies. The annex will focus on development of control strategies for hybrid ventilation, on development of methods to predict hybrid ventilation performance in office buildings and on development...

  12. To Investigate the Influence of Building Envelope and Natural Ventilation on Thermal Heat Balance in Office Buildings in Warm and Humid Climate

    Science.gov (United States)

    Kini, Pradeep G.; Garg, Naresh Kumar; Kamath, Kiran

    2017-07-01

    India’s commercial building sector is witnessing robust growth. India continues to be a key growth market among global corporates and this is reflective in the steady growth in demand for prime office space. A recent trend that has been noted is the increase in demand for office spaces not just in major cities but also in smaller tier II and Tier III cities. Growth in the commercial building sector projects a rising trend of energy intensive mechanical systems in office buildings in India. The air conditioning market in India is growing at 25% annually. This is due to the ever increasing demand to maintain thermal comfort in tropical regions. Air conditioning is one of the most energy intensive technologies which are used in buildings. As a result India is witnessing significant spike in energy demand and further widening the demand supply gap. Challenge in India is to identify passive measures in building envelope design in office buildings to reduce the cooling loads and conserve energy. This paper investigates the overall heat gain through building envelope components and natural ventilation in warm and humid climate region through experimental and simulation methods towards improved thermal environmental performance.

  13. Office Building Occupant's Guide to Indoor Air Quality

    Science.gov (United States)

    ... about physical aspects of the workplace: location, work environment, availability of natural light and the aesthetics of office design, such ... people can do to ensure that their indoor environment is a healthy one. IAQ Building Education and Assessment Model (I-BEAM) : EPA's I-BEAM software program ...

  14. 76 FR 13617 - Office of Federal High-Performance Green Buildings (OFHPGB); Notice of GSA Bulletin OFHPGB 2011...

    Science.gov (United States)

    2011-03-14

    ...-Performance Green Buildings (OFHPGB); Notice of GSA Bulletin OFHPGB 2011-OGP-1 AGENCY: Office of.... Procedures Bulletins regarding the Office of Federal High-Performance Green Building are located on the... Washington, DC 20405 OFFICE OF FEDERAL HIGH-PERFORMANCE GREEN BUILDINGS GSA Bulletin 2011-OGP-1 TO: Heads of...

  15. Issues to Be Solved for Energy Simulation of An Existing Office Building

    Directory of Open Access Journals (Sweden)

    Ki Uhn Ahn

    2016-04-01

    Full Text Available With the increasing focus on low energy buildings and the need to develop sustainable built environments, Building Energy Performance Simulation (BEPS tools have been widely used. However, many issues remain when applying BEPS tools to existing buildings. This paper presents the issues that need to be solved for the application of BEPS tools to an existing office building. The selected building is an office building with 33 stories above ground, six underground levels, and a total floor area of 91,898 m2. The issues to be discussed in this paper are as follows: (1 grey data not ready for simulation; (2 subjective assumptions and judgments on energy modeling; (3 stochastic characteristics of building performance and occupants behavior; (4 verification of model fidelity-comparison of aggregated energy; (5 verification of model fidelity-calibration by trial and error; and (6 use of simulation model for real-time energy management. This study investigates the aforementioned issues and explains the factors that should be considered to address these issues when developing a dynamic simulation model for existing buildings.

  16. Fieldwork measurement of indoor environmental quality (IEQ) in Malaysian platinum-rated green office buildings

    Science.gov (United States)

    Tharim, Asniza Hamimi Abdul; Samad, Muna Hanim Abdul; Ismail, Mazran

    2017-10-01

    An Indoor Environmental Quality (IEQ) fieldwork assessment was conducted in the Platinum-rated GBI office building located in Putrajaya Malaysia. The aim of the study is to determine the current indoor performance of the selected green office building. The field measurement consists of several IEQ parameters counted under the GBI Malaysia namely the Thermal Comfort of temperature, relative humidity, air movement and heat transfer as well as solar radiation. This field measurement also comprises of the measurement for the background noise, visual lighting and Indoor Air Quality (IAQ) focusing on the aspect of carbon dioxide concentration. All the selected indoor parameters were measured for the period of five working days and the results were compared to the Malaysian Standard. Findings of the field measurement show good indoor performance of the Platinum rated office building that complies with the GBI standard. It is hoped that the research findings will be beneficial for future design and construction of office building intended to be rated under the GBI Malaysia.

  17. 2016 Building Technologies Office Peer Review Report

    Energy Technology Data Exchange (ETDEWEB)

    Building Technologies Office

    2016-12-01

    The 2016 Building Technologies Office Peer Review Report summarizes the feedback submitted by reviewers of the 67 BTO projects presented at the 2016 BTO Peer Review. The report presents an overview of the goals and activities under each technology program area, a summary of project scores for each program, and a brief analysis of general evaluation trends within each program area or its constituent subprograms.

  18. Analysis on Zero Energy Consumption Strategy for Office Buildings Lighting in Lianyungang Area

    Science.gov (United States)

    Wu, Dongmei

    2018-01-01

    In recent years, the energy-saving environmental protection has aroused the people’s high concern, and set off a new application practice in China. By analyzing the advantages of the illumination condition in Lianyungang area and combining the content and form of office space, the author puts forward a series of ways and means of energy saving in office building lighting, in order to provide a way for reference to the goal of building Zero energy consumption in the office space environment under the background of green architecture.

  19. Factsheet on Energy Neutral School Buildings and Office Buildings; Infoblad Energieneutrale scholen en kantoren

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-15

    A brief overview is given of all aspects of energy-neutral building and renovating school and office buildings. Besides technique, also attention is given to process, financing, management and maintenance. This factsheet is part of a series of three factsheets on energy neutral construction of houses and buildings. The other two are: 'Factsheet on Energy Neutral Building : Definition and ambition' and 'Factsheet on Energy Neutral Building' [Dutch] Een kort overzicht wordt gegeven van alle aspecten van energieneutraal bouwen en renoveren van woningen. Naast techniek komen ook proces, financiering en beheer en onderhoud aan de orde. Dit Infoblad maakt deel uit van een serie van drie Infobladen over energieneutraal bouwen voor woningen en gebouwen. De andere twee zijn: 'Infoblad Energieneutraal bouwen: definitie en ambitie' en 'Infoblad Energieneutrale Woningbouw'.

  20. Impacts of orientation on daylighting in high-rise office buildings in Malaysia

    Directory of Open Access Journals (Sweden)

    AbdolHamid Mahdavi

    2015-12-01

    Full Text Available Orientation is one of the important factors in building design to use daylight and ‎conserve energy. Well-orientated buildings maximise daylight reception through ‎building facades and reduce the need for artificial lighting. Reasonable daylighting usage in office buildings is an important part of an architect’s designing process, which leads to lesser electricity consumption as well as providing a visual and thermal comfort for the occupants. Orientation is an important factor in passive design strategies. This paper focuses on the orientation effect on daylighting into office rooms. The research method of this study was simulation which is performed on a hypothetical model on a 25 storey high-rise office building in Malaysia. All simulations were carried out in the IES-VE software that uses RADIANCE program for illuminance calculations. To evaluate the daylight in various conditions, a new index SAZ was introduced which assesses daylight factor (DF and absolute Lux. Results showed similar SAZ in CIE overcast sky in various orientations; whereas, in sunny sky due to sun path in Malaysia, different results showed northern and southern rooms have the best illuminance distribution. However, the similar window form and size in four orientations lead to more energy consumption for artificial lighting and cooling loads.

  1. Effect of renovating an office building on occupants' comfort and health

    DEFF Research Database (Denmark)

    Pejtersen, Jan; Brohus, H.; Hyldgaard, C. E.

    2001-01-01

    . Before the floor material was installed in the office building, a full-scale exposure experiment was performed in the laboratory. The new ventilation strategy and renovation of the HVAC system were selected on the basis of laboratory experiments on a full-scale mock-up of a cellular office. The severity...

  2. Solar-Heated and Cooled Office Building--Columbus, Ohio

    Science.gov (United States)

    1982-01-01

    Final report documents solar-energy system installed in office building to provide space heating, space cooling and domestic hot water. Collectors mounted on roof track Sun and concentrate rays on fluid-circulating tubes. Collected energy is distributed to hot-water-fired absorption chiller and space-heating and domestic-hot-water preheating systems.

  3. Towards critical performance considerations for using office buildings as a power flexibility resource-a survey

    NARCIS (Netherlands)

    Aduda, K.O.; Labeodan, T.; Zeiler, W.

    2018-01-01

    The continued growth in variable renewable energy sources (VRES) has created increased focus on the use of office buildings for power flexibility activities. Office buildings uniquely present opportunities for relatively easy control adaptation during power flexibility activities given their large

  4. Occupant satisfaction with the acoustical environment : green office buildings before and after treatment

    Energy Technology Data Exchange (ETDEWEB)

    Hodgson, M. [British Columbia Univ., Vancouver, BC (Canada). School of Occupational and Environmental Hygiene, Acoustics and Noise Research Group

    2009-07-01

    Sustainable architecture is meant to preserve the environment and conserve natural resources, as well as provide an environment for the occupants that promotes wellbeing and productivity. Occupants generally claim that the acoustical environment is the least satisfactory aspect of green office buildings. They are dissatisfied with excessive noise and poor speech privacy. This paper reported on the results of 2 studies of the acoustical environments in green office buildings before and after acoustical-control measures were installed. Acoustical quality was evaluated by occupant-satisfaction surveys and acoustical-parameter measurements. The first study, which involved 6 green office buildings, showed that buildings designed to obtain LEED ratings are unlikely to have satisfactory acoustical environments. A naturally-ventilated, green university building with a poor acoustical environment was examined in the second study. The results of this study suggest that improving acoustical environments in green buildings requires good acoustical design, with input from an acoustical specialist from the beginning of the design process. The design should consider site selection and building orientation; external envelope and penetrations in it; building layout and internal partitions; HVAC systems; appropriate dimensioning of spaces; and the amount and location of sound absorbing treatments. The study also showed that a building's energy efficiency, lighting, ventilation, air-quality and acoustics are interconnected, and that no aspect can be successfully designed in isolation. It was concluded that optimized engineering-control measures can improve poor acoustical environments. 11 refs., 1 tab., 1 fig.

  5. Effect of facade components on energy efficiency in office buildings

    International Nuclear Information System (INIS)

    Ihara, Takeshi; Gustavsen, Arild; Jelle, Bjørn Petter

    2015-01-01

    Highlights: • Investigation of facade properties for energy efficiency of Tokyo office buildings. • Higher reflectance for opaque parts may slightly reduce energy demand. • Lower window U-value and solar heat gain coefficient are potential solutions. • Decreased heating due to insulation did not always compensate increased cooling. • Fundamental data for adjustment of facade properties of buildings are provided. - Abstract: Properties of facade materials should be considered to determine which of them strongly affect building energy performance, regardless of the building shapes, scales, ideal locations, and building types, and thus may be able to promote energy efficiency in buildings. In this study, the effects of four fundamental facade properties related to the energy efficiency of office buildings in Tokyo, Japan, were investigated with the purpose of reducing the heating and cooling energy demands. Some fundamental design factors such as volume and shape were also considered. It was found that the reduction in both the solar heat gain coefficient and window U-value and increase in the solar reflectance of the opaque parts are promising measures for reducing the energy demand. Conversely, the reduction in the U-value of the opaque parts decreased the heating energy demand, and this was accompanied by an increase in the cooling energy demand in some cases because the total energy demands were predominantly for cooling. The above-mentioned promising measures for reducing building energy demands are thus recommended for use, and an appropriate U-value should be applied to the opaque parts based on careful considerations. This study provides some fundamental ideas to adjust the facade properties of buildings.

  6. Leverkusen revenue office building with geothermal and district heating; Finanzamt Leverkusen setzt auf Geothermie und Fernwaerme

    Energy Technology Data Exchange (ETDEWEB)

    Keveloh, Holger [Depenbrock Systembau GmbH und Co. KG, Bielefeld (Germany); Paterak, Anette; Wiemer, Bianca; Foerschler, Eberhard [Assmann Beraten+Planen GmbH, Dortmund (Germany)

    2011-07-01

    Efficient air conditioning of office buildings is possible with concrete core activation via a geothermal heat pump. The new building of the revenue office at Leverkusen will use this technology. (orig.)

  7. A Prospective Study of Ventilation Rates and Illness Absence in California Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Eliseeva, Ekaterina A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Spears, Michael [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Chan, Wanyu R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Cohn, Sebastian [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sullivan, Douglas P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-10-07

    Background – This study investigated the associations of ventilation rates (VRs), estimated from indoor CO2 concentrations, in offices with the amount of respiratory infections, illness absences, and building-related health symptoms in occupants. Methods – Office buildings were recruited from three California climate zones. In one or more study spaces within each building, real-time logging sensors measured carbon dioxide, temperature, and relative humidity for one year. Ventilation rates were estimated using daily peak CO2 levels, and also using an alternative metric. Data on occupants and health outcomes were collected through web-based surveys every three months. Multivariate models were used to assess relationships between metrics of ventilation rate or CO2 and occupant outcomes. For all outcomes, negative associations were hypothesized with VR metrics, and positive associations with CO2 metrics. Results – Difficulty recruiting buildings and low survey response limited sample size and study power. In 16 studied spaces within 9 office buildings, VRs were uniformly high over the year, from twice to over nine times the California office VR standard (7 L/s or 15 cfm per person). VR and CO2 metrics had no statistically significant relationships with occupant outcomes, except for a small significantly positive association of the alternative VR metric with respiratory illness-related absence, contrary to hypotheses. Conclusions– The very high time-averaged VRs in the California office buildings studied presumably resulted from “economizer cycles” bringing in large volumes of outdoor air; however, in almost all buildings even the estimated minimum VRs supplied (without the economizer) substantially exceeded the minimum required VR. These high VRs may explain the absence of hypothesized relationships with occupant outcomes. Among uniformly high VRs, little variation in contaminant concentration and occupant effects would be expected. These findings may

  8. Effect of geometric factors on the energy performance of high-rise office towers in Tianjin, China

    OpenAIRE

    Liu, Li; Wu, Di; Li, Xiaojun; Hou, Shanshan; Liu, Conghong; Jones, Phillip John

    2017-01-01

    To improve energy efficiency of office buildings in Tianjin, we select a prototypical high-rise office tower as an example and focus on the effect of geometric factors on building energy performance. These factors include the orientation, plane shape, floor area, plane shape factor (the ratio of the plane length to the plane width, only as regards to a rectangle-shaped plane), floor height, floor number and window-to-wall ratio. The simulation is performed in DesignBuilder, which integrates a...

  9. Sick-building symptoms in office workers in northeastern France: a pilot study.

    Science.gov (United States)

    Teculescu, D B; Sauleau, E A; Massin, N; Bohadana, A B; Buhler, O; Benamghar, L; Mur, J M

    1998-07-01

    To verify that sick building symptoms are present in north-eastern France office workers; to try to identify new confounding factors. The design was that of a cross-sectional study with control group. We studied with the same methods the personnel of an air-conditioned building (n=425), and of a naturally ventilated building (n=351). Air temperature and humidity, bacterial and fungal densities were measured by the same technical staff in the two buildings. A standard questionnaire on irritative and respiratory symptoms, personal and family history, and lifestyle was completed by the participants. In univariate analysis, exposure to air-conditioning was associated with an increased prevalence of symptoms (odds ratios-OR-between 1.54 and 2.84). A significant increase in sickness absence was also found among subjects working in air-conditioned offices. As a series of factors were suspected to interfere with these associations, logistic regression was applied. This method confirmed exposure to be an independent determinant of 7 symptoms, and also identified two determinants not previously described: a family history of respiratory diseases and "do-it-yourself' activities. we found the sick building symptoms to be present in a group of French office workers exposed to air-conditioning. We confirmed the influence of a number of confounding factors and described two further confounders - do-it-yourself activities at home and a history of familial respiratory disease.

  10. Integrated Building Energy Design of a Danish Office Building Based on Monte Carlo Simulation Method

    DEFF Research Database (Denmark)

    Sørensen, Mathias Juul; Myhre, Sindre Hammer; Hansen, Kasper Kingo

    2017-01-01

    The focus on reducing buildings energy consumption is gradually increasing, and the optimization of a building’s performance and maximizing its potential leads to great challenges between architects and engineers. In this study, we collaborate with a group of architects on a design project of a new...... office building located in Aarhus, Denmark. Building geometry, floor plans and employee schedules were obtained from the architects which is the basis for this study. This study aims to simplify the iterative design process that is based on the traditional trial and error method in the late design phases...

  11. Pollution prevention opportunity assessment for Building 922 solid office waste

    International Nuclear Information System (INIS)

    Phillips, N.M.

    1995-01-01

    Building 922 houses all of SNL/California's ES and H Departments: Health Protection, Environmental Protection, Safety, and Environmental Operations. It covers approximately 10,000 square feet and houses about 80 people. The office personnel generate nonhazardous solid office wastes in their daily activities. To determine the types and amounts of waste generated, a special PPOA sorting team sorted all of the trash collected from the building for a period of one-week (including paper and aluminum cans in the recycling bins). The team sorted the trash into major categories: paper, plastic, metals, glass, wet garbage, rest room waste, and miscellaneous materials. They then sorted it into subcategories within each major category. Rest room waste was collected but not sorted. The waste in each category was weighed separately. The total amount of trash collected during the week was approximately 168.8 kg (371.4 lbs). The results of this PPOA indicate that SNL/California is minimizing most nonhazardous office waste and reductions planned for the near future will add significantly to the minimization efforts

  12. The thermal environment and occupant perceptions in European office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Stoops, J L [Chalmers Univ. of Tech., Goeteborg (Sweden). Dept. of Building Services Engineering

    2002-02-01

    The results from a large field study of thermal comfort in European office buildings are reported. Environmental conditions and occupant perceptions were collected over fourteen months from twenty-six different office buildings located in France, Greece, Portugal, Sweden and the UK. This thesis focuses on the thermal measurements and occupant perceptions; however, some of the additional variables with strong connections to thermal sensation are also examined. A summary of human comfort is presented to help place this thesis in appropriate context. The summary presents thermal comfort issues within a broad framework of environmental comfort including physical, physiological, behavioural, psychological and other variables. A more narrowly focused overview of current thermal comfort research is also included. The work attempts to show relationships and produce useful information from the data set by using rather simple statistics and graphical methods. The objective is to quite literally use the data set to illustrate the actual thermal conditions in European office buildings and the occupant perceptions of those conditions. The data are examined in some detail with key relationships identified and explored. Significant differences between countries, both for the physical conditions and the perceptions of those conditions are identified. In addition, the variation over the course of the year for each country is explored. The variations occur in complex ways, which make simple, all encompassing explanations impossible. The nature and size of the variations make the application of simple Europe wide models of thermal comfort questionable. It appears that individuals in different European countries have different expectations for their indoor office thermal environment. This data set will be further explored in a more complete study, which will examine the other measured variables.

  13. Indoor environmental quality and ventilation in U.S. office buildings: A view of current issues

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, W.J.

    1994-11-01

    Much of the current focus on indoor environmental quality and ventilation in US office buildings is a response to sick building syndrome and occupant complaints about building-related health symptoms, poor indoor air quality, and thermal discomfort. The authors know that serious ``sick-building`` problems occur in a significant number of US office buildings and that a significant proportion of the occupants in many normal (non-sick) buildings report building-related health symptoms. Concerns about the health effects of environmental tobacco smoke have also focused attention on the indoor environment. The major responses of industry and governments, underway at the present time, are to restrict smoking in offices, to attempt to reduce the emissions of indoor pollutants, and to improve the operation of heating, ventilating and air conditioning (HVAC) systems. Better air filtration, improved HVAC commissioning and maintenance, and increased provisions for individual control of HVAC are some of the improvements in HVAC that are currently being, evaluated. In the future, the potential for improved productivity and reduced airborne transmission of infectious disease may become the major driving force for improved indoor environments.

  14. Energy consumption, energy savings, and emission analysis in Malaysian office buildings

    International Nuclear Information System (INIS)

    Saidur, R.

    2009-01-01

    This paper is concerned with the estimation of energy use in office buildings in Malaysia and with the energy use of major equipment. Energy intensity (EI) - a measure of a building's energy performance - is estimated for Malaysia and compared with a number of selected countries. Air conditioners are shown to be the major energy users (57%) in office buildings, followed by lighting (19%), lifts and pumps (18%) and other equipment (6%). It is estimated that 77,569 MWh of energy can be saved and a huge reduction of emissions achieved through the application of advance glazing, compact fluorescent lamps (CFL), insulation, housekeeping, and by raising thermostat set point temperature of air conditioners, and reducing EI. It is also estimated that a very substantial amount of energy can be saved by making use of energy-efficient motors in building systems with different motor loading percentages. Finally, it can be shown that the use of variable speed drives (VSDs) and energy-efficient motors leads to substantial energy savings and an enormous reduction in emissions.

  15. 11 CFR 100.84 - Office building for State, local, or district party committees or organizations.

    Science.gov (United States)

    2010-01-01

    ... 11 Federal Elections 1 2010-01-01 2010-01-01 false Office building for State, local, or district party committees or organizations. 100.84 Section 100.84 Federal Elections FEDERAL ELECTION COMMISSION GENERAL SCOPE AND DEFINITIONS (2 U.S.C. 431) Exceptions to Contributions § 100.84 Office building for...

  16. 11 CFR 100.144 - Office building for State, local, or district party committees or organizations.

    Science.gov (United States)

    2010-01-01

    ... 11 Federal Elections 1 2010-01-01 2010-01-01 false Office building for State, local, or district party committees or organizations. 100.144 Section 100.144 Federal Elections FEDERAL ELECTION COMMISSION GENERAL SCOPE AND DEFINITIONS (2 U.S.C. 431) Exceptions to Expenditures § 100.144 Office building for...

  17. [Biological contamination in office buildings related to ventilation/air conditioning system].

    Science.gov (United States)

    Bródka, Karolina; Sowiak, Małgorzata; Kozajda, Anna; Cyprowski, Marcin; Irena, Szadkowska-Stańczyk

    2012-01-01

    Indoor air is contaminated with microorganisms coming from both the atmospheric air and sources present in premises. The aim of this study was to analyze the concentrations of biological agents in office buildings, dependending on ventilation/air conditioning system and season. The study covered office buildings (different in the system of ventila-tion/air conditioning). Air samples for assessing the levels of inhalable dust, endotoxins and (1-->3)-beta-D-glucans, were taken at the selected stationary points of each building during summer and winter. The air was sampled for 6 h, using portable sets consisting of the GilAir 5 pump and the head filled with a filter of fiber glass. The samples for the presence of airborne bacteria and fungi were collected twice during the day using the impaction method. Average concentrations of inhalable dust, bacteria, fungi, endotoxins and (1-->3)-beta-D-glucans in office premises were 0.09 mg/m3, 6.00 x 10(2) cfu/m3, 4.59 x 10(1) cfu/m3, 0.42 ng/m3 and 3.91 ng/m3, respectively. Higher concentrations of the investigated agents were found in summer. In premises with air conditioning concentrations of airborne fungi, (1-->3)-beta-D-glucans and inhalable dust were significantly lower in winter. In summer the trend was reverse except for (1-->3)-beta-D-glucans. Concentrations of biological agents were affected by the season and the presence of air conditioning. Concentrations of inhalable dust, bacteria, fungi, endotoxins and (1-->3)-beta-D-glucans, observed inside the office buildings, were significantly higher in summer than in winter. The presence of the air conditioning system modified in various ways the levels of biological agents. Its influence was greater on the concentration of fungi and (1-->3)-beta-D-glucans than on that of bacteria and endotoxins.

  18. Buildings move. The benefit of sustainable renovation of office buildings; Gebouwen bewegen. De winst van duurzame kantoorrenovatie

    Energy Technology Data Exchange (ETDEWEB)

    Van Miert, M. [Bureau Van Miert, Breda (Netherlands); De Ruiter, P. [Architectenbureau Paul de Ruiter, Amsterdam (Netherlands); Verburgt, P.

    2012-05-15

    Within the programme 'EnergieSprong' the development of the so-called Transition Formula was initiated that shows how existing offices can be renovated into energy efficient or even energy neutral buildings. A multidisciplinary view on the existing office buildings stock and users' demand has led to four renovation strategies which are described in this book [Dutch] EnergieSprong heeft het initiatief genomen dit boek te ontwikkelen waarin de Transitieformule laat zien hoe het vandaag de dag mogelijk is om bestaande kantoren heel energiezuinig of zelfs energieneutraal te renoveren. Een multidisciplinaire kijk op de bestaande kantorenvoorraad en de huidige vraag van gebruikers heeft geleid tot een viertal renovatiestrategieen die in dit boek beschreven worden.

  19. Assessment of indoor air quality in office buildings across Europe - The OFFICAIR study.

    Science.gov (United States)

    Mandin, Corinne; Trantallidi, Marilena; Cattaneo, Andrea; Canha, Nuno; Mihucz, Victor G; Szigeti, Tamás; Mabilia, Rosanna; Perreca, Erica; Spinazzè, Andrea; Fossati, Serena; De Kluizenaar, Yvonne; Cornelissen, Eric; Sakellaris, Ioannis; Saraga, Dikaia; Hänninen, Otto; De Oliveira Fernandes, Eduardo; Ventura, Gabriela; Wolkoff, Peder; Carrer, Paolo; Bartzis, John

    2017-02-01

    The European project OFFICAIR aimed to broaden the existing knowledge regarding indoor air quality (IAQ) in modern office buildings, i.e., recently built or refurbished buildings. Thirty-seven office buildings participated in the summer campaign (2012), and thirty-five participated in the winter campaign (2012-2013). Four rooms were investigated per building. The target pollutants were twelve volatile organic compounds, seven aldehydes, ozone, nitrogen dioxide and particulate matter with aerodynamic diameter indoor air concentrations of formaldehyde and ozone did not exceed their respective WHO air quality guidelines, and those of acrolein, α-pinene, and d-limonene were lower than their estimated thresholds for irritative and respiratory effects. PM 2.5 indoor concentrations were higher than the 24-h and annual WHO ambient air quality guidelines. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Ninety-six hours to build a prototype robot showing human emotions

    CERN Multimedia

    Stefania Pandolfi

    2016-01-01

    Thirty-five Master's students in the fields of business, design and engineering participated in an intensive five-day project-based introduction to programming and advanced electronics. The goal of the initiative was to build a fully functional prototype robot able to communicate and show at least four basic human emotions.    A group of students is presenting a prototype robot showing human emotions at IdeaSquare. With no previous experience in electronics or coding, groups of students from Portugal, Italy, Norway and Estonia were introduced to the basics of sensors, integrated circuits and actuators, and after just 96 hours they presented their functioning robots at IdeaSquare on Friday, 15 January. These robots, mostly built around Arduino boards and recycled materials, were able to display different human emotions as a response to external environmental inputs. The five-day workshop, called öBot, was organised by the IdeaSquare te...

  1. How can new technology, improve façade construction of office building, in Iran

    OpenAIRE

    Saberi, Akbar

    2014-01-01

    It is evident that available technologies on office building sector in Shiraz relay on traditional construction especially on wet methods. Wet system process depends on human interpretation (The human interpretation is the basics of the systems) which cause major problems in construction quality. For this propose this dissertation focus on construction method in office building in Iran. Compared to wet construction, dry system is new technology in the construction industry. ...

  2. Comfort Study of Office Buildings with Large Glazed Areas

    Directory of Open Access Journals (Sweden)

    Violeta Motuzienė

    2017-09-01

    Full Text Available In the buildings with large glazed areas the biggest problem is the space overheating during the warm season. This causes increased energy demand for cooling. The survey was carried out during the warm and cold seasons in two office buildings with large glazed areas. The methodology was prepared for evaluating indoor climate parameters using objective and subjective evaluation. The measurements have shown that there are problems with lighting in workplaces of both buildings during both the warm and cold seasons. The biggest problem is too dry air during the cold period, an acceptable temperature is also not always in the building No. 2. The survey has shown that some employees are dissatisfied with the indoor climate in the workplace, the bigger dissatisfaction is in building No. 2. Assessing according to the O. Fanger methodology was obtained that the number of PPD is in the normal range during the cold period, whereas close to the limit when the building can not be operated in the warm period.

  3. Perceived Indoor Environment and Occupants' Comfort in European "Modern" Office Buildings: The OFFICAIR Study.

    Science.gov (United States)

    Sakellaris, Ioannis A; Saraga, Dikaia E; Mandin, Corinne; Roda, Célina; Fossati, Serena; de Kluizenaar, Yvonne; Carrer, Paolo; Dimitroulopoulou, Sani; Mihucz, Victor G; Szigeti, Tamás; Hänninen, Otto; de Oliveira Fernandes, Eduardo; Bartzis, John G; Bluyssen, Philomena M

    2016-04-25

    Indoor environmental conditions (thermal, noise, light, and indoor air quality) may affect workers' comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants' comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 "modern" office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain). Occupants assessed indoor environmental quality (IEQ) using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality), and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor) of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants' comfort. The highest association with occupants' overall comfort was found for "noise", followed by "air quality", "light" and "thermal" satisfaction. Analysis of detailed parameters revealed that "noise inside the buildings" was highly associated with occupants' overall comfort. "Layout of the offices" was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index), and building characteristics (office type and building's location). Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants.

  4. Prototypic implementations of the building block for component based open Hypermedia systems (BB/CB-OHSs)

    DEFF Research Database (Denmark)

    Mohamed, Omer I. Eldai

    2005-01-01

    In this paper we describe the prototypic implementations of the BuildingBlock (BB/CB-OHSs) that proposed to address some of the Component-based Open Hypermedia Systems (CB-OHSs) issues, including distribution and interoperability [4, 11, 12]. Four service implementations were described below. The...

  5. Competing explanations for adopting energy innovations for new office buildings

    International Nuclear Information System (INIS)

    Vermeulen, Walter J.V.; Hovens, Jeroen

    2006-01-01

    An integrative model to explain potential adopters' decisions to adopt energy innovations was adapted and applied in the field of new office building construction. We tested the relative effects of competing theoretical explanations (derived from economics, innovation science and policy science) on the decision to adopt. The research covered 35 projects representing 9% of the total volume of new office construction in the Netherlands between 2000 and mid-2002. Two levels of explanations for adopting innovations were derived: (a) the potential adopter's weighed assessments of the innovations and his or her nature of decision making and (b) explanation of those first-level variables. Using multiple regression techniques, we determined the relative influence on innovation-adoption of variables covering economy and technology, government intervention, company characteristics, and influences from market and society. The decision to adopt 'mature' innovations, in contrast to 'young' innovations, is based more on routine procedures than project-specific considerations. Policies need to take this difference into consideration. We also show evidence that in promoting adoption of E-innovations for new office buildings the Dutch system of applying Energy Performance Standards and subsidies proofs to be effective

  6. Grand Junction Projects Office Remedial Action Project Building 2 public dose evaluation. Final report

    International Nuclear Information System (INIS)

    Morris, R.

    1996-05-01

    Building 2 on the U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) site, which is operated by Rust Geotech, is part of the GJPO Remedial Action Program. This report describes measurements and modeling efforts to evaluate the radiation dose to members of the public who might someday occupy or tear down Building 2. The assessment of future doses to those occupying or demolishing Building 2 is based on assumptions about future uses of the building, measured data when available, and predictive modeling when necessary. Future use of the building is likely to be as an office facility. The DOE sponsored program, RESRAD-BUILD, Version. 1.5 was chosen for the modeling tool. Releasing the building for unrestricted use instead of demolishing it now could save a substantial amount of money compared with the baseline cost estimate because the site telecommunications system, housed in Building 2, would not be disabled and replaced. The information developed in this analysis may be used as part of an as low as reasonably achievable (ALARA) cost/benefit determination regarding disposition of Building 2

  7. Effects of bedrock type on the indoor radon concentrations at the office buildings in Gyeongju, Korea

    Directory of Open Access Journals (Sweden)

    Park Hee Chan

    2011-01-01

    Full Text Available This study measured the indoor radon concentrations at 23 administrative office buildings in Gyeongju, Korea, which consists of 23 administrative districts. Using the Korean geological information system, the type of bedrock under the administrative office buildings was identified and classified in 3 major types: granite, sedimentary rock, and sedimentary rock-based fault. The changes in the indoor concentrations at the 23 administrative office buildings were analyzed according to the type of bedrock. As a result, the radon concentration in the areas with the granite bedrock was generally higher than that in the region of two other types of bedrock. In addition, the radon concentration was evaluated according to surface area and construction timing of the building. The indoor radon concentration generally increased with decreasing surface area of the building, particularly in granite distributed areas. For a building aged more than 15 years, the radon concentration in the building in the granite area was much higher. For the building aged 1 or 2 years, the radon concentration was high regardless of the type of the bedrock due to radon emanation from the building material, such as concrete.

  8. Energy Conservation in an Office Building Using an Enhanced Blind System Control

    Directory of Open Access Journals (Sweden)

    Edorta Carrascal-Lekunberri

    2017-02-01

    Full Text Available The two spaces office module is usually considered as a representative case-study to analyse the energetic improvement in office buildings. In this kind of buildings, the use of a model predictive control (MPC scheme for the climate system control provides energy savings over 15% in comparison to classic control policies. This paper focuses on the influence of solar radiation on the climate control of the office module under Belgian weather conditions. Considering MPC as main climate control, it proposes a novel distributed enhanced control for the blind system (BS that takes into account part of the predictive information of the MPC. In addition to the savings that are usually achieved by MPC, it adds a potential 15% improvement in global energy use with respect to the usually proposed BS hysteresis control. Moreover, from the simulation results it can be concluded that the thermal comfort is also improved. The proposed BS scheme increases the energy use ratio between the thermally activated building system (TABS and air-handling unit (AHU; therefore increasing the use of TABS and allowing economic savings, due to the use of more cost-effective thermal equipment.

  9. Method for Cost-Benefit Analysis of Improved Indoor Climate Conditions and Reduced Energy Consumption in Office Buildings

    Directory of Open Access Journals (Sweden)

    Viktoras Dorosevas

    2013-09-01

    Full Text Available Indoor climate affects health and productivity of the occupants in office buildings, yet in many buildings of this type indoor climate conditions are not well-controlled due to insufficient heating or cooling capacity, high swings of external or internal heat loads, improper control or operation of heating, ventilation and air conditioning (HVAC equipment, etc. However, maintenance of good indoor environmental conditions in buildings requires increased investments and possible higher energy consumption. This paper focuses on the relation between investment costs for retrofitting HVAC equipment as well as decreased energy use and improved performance of occupants in office buildings. The cost-benefit analysis implementation algorithm is presented in this paper, including energy survey of the building, estimation of occupants dissatisfied by key indoor climate indicators using questionnaire survey and measurements. Technique for Order Preference by Similarity to Ideal Solution (TOPSIS analysis is used in the proposed method for data processing. A case study of an office building is presented in order to introduce an application example of the proposed method. Results of the study verify the applicability of the proposed algorithm and TOPSIS analysis as a practical tool for office building surveys in order to maximize productivity by means of cost efficient technical building retrofitting solutions.

  10. Evaluation and analysis of energy consumption in office buildings; Feldstudie zum Energieverbrauch von Buerogebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Maas, Stefan; Scholzen, Frank; Thewes, Andreas; Waldmann, Daniele [Universitaet Luxemburg, Campus Kirchberg, Fakultaet fuer Naturwissenschaften, Technologie und Kommunikation, Forschungseinheit Ingenieurswissenschaften, Luxemburg (Luxembourg); Zuerbes, Arno [Fachhochschule Bingen, Fachbereich Technik, Informatik und Wirtschaft, Bingen am Rhein (Germany)

    2011-06-15

    During the last years the national energy consumption of Luxembourg shifted noticeable towards the building sector. In 1990 71 % of the total domestic end energy consumption was ascribed to industrial sector and only 20 % to the building sector. The distribution changed significantly and in 2005 the energy consumption dedicated to industrial sector represented only 44 %, transport 25 % and the tertiary sector 31 % [1], which includes private and public households as well as non-residential buildings. The buildings account for 40 % of total energy consumption in the EU and there is an enormous energy saving potential. Therefore the EUdirective 2002/91/EG [2] requires from all EU Member States to save energy in this sector. Hence the energy saving of buildings present an essential part of climate protection. Furthermore the new directive 2010/31/EG [3] requires from the Member States to tighten national standards and to draw up national plans for increasing the number of nearly zero-energy buildings. But for a better understanding of energy flows in buildings and to develop energy saving concepts as well as to estimate possible energy savings of buildings a detailed analysis of energy consumption databases is an important precondition. The following field survey monitors 47 office buildings in Luxembourg. A separate gathering of electricity, heat and cooling energy consumptions allowed a detailed energetic analysis. A statistical analysis and interpretation of new buildings differentiated by energy sources as well as definition of energy relevant parameters like the window ratio, the construction method, the type of use or the kind of technical installations show the problems of typical existing office buildings. A final extrapolation to the population of all new office buildings in Luxembourg helps to estimate the energy saving potential.

  11. Performance of a prototype micro wind turbine in the manmade wind field from air conditioner of buildings

    Directory of Open Access Journals (Sweden)

    K. H. Goh

    2012-03-01

    Full Text Available Harnessing waste energy from the manmade air fields of buildings presents a new area of renewable energy to explore. Due to the unpredictability of the natural wind, this study is to evaluate the practicality for harnessing waste energy from the air conditioner exhaust units which are a more constant and predictable source available in the buildings. A prototype of the micro wind turbine has been designed to minimize the negative effect of the exhaust sources. After the micro wind turbine was manufactured, the performance of the turbine was tested in the selected air conditioner exhaust unit. Increasing the rotor solidity and decreasing the resistance of the generator contribute to improved starting torque and decreased generator break in torque respectively in the design. The power generation of the micro wind turbine increases with an increase of the rotor speed. The 24-hour operation of the prototype presents an observation for both exhaust performance and power generation prediction when the prototype is mounted on the exhaust unit.

  12. What Role Does The Executive Officer Play In Ensuring Senior Officer Success Building An Organization Of Trust Is Key

    Science.gov (United States)

    2016-02-16

    AIR WAR COLLEGE AIR UNIVERSITY WHAT ROLE DOES THE EXECUTIVE OFFICER PLAY IN ENSURING SENIOR OFFICER SUCCESS? BUILDING AN ORGANIZATION OF...talk, demonstrate respect, create transparency, right wrongs, show loyalty , deliver results, get better, confront reality, clarify expectations...When speaking for the senior leader, the exec must ensure commander’s intent is conveyed clearly and accurately. It is for this reason that execs

  13. Utilizing a Rapid Prototyping Approach in the Building of a Hypermedia-Based Reference Station.

    Science.gov (United States)

    Sell, Dan

    This paper discusses the building of a hypermedia-based reference station at the Wright Laboratory Technical Library, Wright-Patterson Air Force Base, Ohio. Following this, the paper focuses on an electronic user survey from which data is collected and analysis is made. The survey data is used in a rapid prototyping approach, which is defined as…

  14. Simulation Study of Active Ceilings with Phase Change Material in Office Buildings for Different National Building Regulations

    DEFF Research Database (Denmark)

    Farhan, Hajan; Stefansen, Casper; Bourdakis, Eleftherios

    2018-01-01

    The aim of this study was to examine the performance of phase change material (PCM) in active ceilings for an office room under different Danish building regulations for both heating and cooling purposes. A model of a two-person office room was simulated with the only heating and cooling source...... being radiant ceiling panels containing PCM. The target was to reduce energy use for the simulation models and still meet the recommended criteria of Category II for the European Standard EN 15251:2007 namely, 23°C – 26°C (73.4°F – 78.8°F) during summer and between 20°C – 24°C (68.0°F – 73.4°F) during...... winter. The office model was simulated for a whole year and analyzed for three Danish building regulations BR10 (2010), BR15 (2015) and BR20 (2020). The results show that the indoor environment was within the desired Category II, according to EN 15251 for the whole occupancy period. The predicted...

  15. Indoor environmental quality differences between office types in LEED-certified buildings in the US

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young S. [School of Planning, Design, and Construction, Michigan State University, East Lansing, MI 48823 (United States); Guerin, Denise A. [College of Design, University of Minnesota, Twin Cities, MN 55108 (United States)

    2010-05-15

    The study compared IAQ, thermal quality, and lighting quality between 5 different office types in LEED-certified buildings in relation to employees' environmental satisfaction and their job performance. This was to provide workplaces where workers in each specific office environment could be provided with appropriate office settings regarding these IEQ criteria when organizations comply with LEED standards. The five types of office included private enclosed, private shared, open-plan with high cubicle over 5', open-plan with low cubicle lower than 5', and open-plan with no partitions (bullpen) offices. The study found IAQ enhanced workers' job performance in enclosed private offices more than both high cubicles and low cubicles. All four office types had higher satisfaction with the amount of light and visual comfort of light as well as more enhancement with job performance due to lighting quality than high cubicles. There was no difference in thermal quality between the five office types. IAQ and lighting quality were not different between enclosed private, enclosed shared, and bullpen office types, either. The study findings suggest a careful workplace design considering the height of partitions in LEED-certified buildings to improve employee's environmental satisfaction and job performance. (author)

  16. Assessing and Reducing Plug and Process Loads in Office Buildings (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2011-06-01

    Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly large fraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in office spaces are poorly understood.

  17. Thermal and lighting perception in four fully glazed office buildings in Santiago, Chile

    Directory of Open Access Journals (Sweden)

    Claudio Vásquez Záldivar

    2013-12-01

    Full Text Available This paper is part of a general research project whose main objective is to establish a baseline for post-occupancy energy consumption and indoor environmental quality for office buildings in Santiago, Chile. This study aims at understanding how architectonical variables relate to, and can even determine, user comfort perception.  Thus, one-year continuous monitoring in several floors at four office buildings was performed and seasonal surveys were completed.  Survey participants were asked a series of questions regarding spatial orientation and comfort perception in their workspace.The data from the comfort survey and onsite measurements such as season of the year, case study, type of workspace and possibility of an outdoor view from the workstation were contrasted with the components obtained by a Principal Component Analysis (PCA. Three components were selected from the PCA, and three Maps of Perception (MP were produced. These maps were then analyzed and interpreted so as to obtain information on the general perception of thermal and lighting comfort at workspaces within several office buildings in Santiago.

  18. Zero energy office building renovation; Energieneutrale kantoorrenovatie

    Energy Technology Data Exchange (ETDEWEB)

    Deguelle, D.; Krijnen, M. [DHV, Amersfoort (Netherlands); Heijnis, J. [cepezed, Delft (Netherlands)

    2011-04-15

    Building Brains has been set up by TNO as a cooperative and started September 21, 2009. The aim of the project was to answer the question how the energy consumption in the Netherlands can be reduced by 50% up to 2030 or how the built environment can be made energy-neutral. This issue of the magazine is dedicated to Building Brains project. Four different renovation concepts are compared: energy-neutral renovation that involves the exclusive use of sustainable generated energy;.the application of the passive construction principles; the use of Double Skin Facades; and decentralized facade-integrated installation techniques. Following the results of this study two optimized refurbishment approaches for a zero energy office are designed. [Dutch] Building Brains is een door TNO opgezet samenwerkingsproject dat op 21 september 2009 van start ging. Het doel van het project is antwoord te geven op de vraag hoe tot 2030 het energiegebruik in Nederland kan worden gehalveerd of hoe de gebouwde omgeving energieneutraal kan worden gemaakt. Deze aflevering van het tijdschrift TVVL is vrijwel geheel gewijd aan het Building Brains project. Er is onderzocht hoe verschillende renovatieconcepten scoren. Er zijn vier renovatieconcepten met elkaar vergeleken: energie neutraal renoveren door middel van duurzame energieopwekking, toepassen van het passiefhuisprincipe, toepassen van een tweedehuidfacade en toepassen van een decentrale, gevel-geintegreerde installatie. Uit de studie kwamen twee geoptimaliseerde concepten voor een energieneutrale kantoorrenovatie naar voren.

  19. Development of a new energy benchmark for improving the operational rating system of office buildings using various data-mining techniques

    International Nuclear Information System (INIS)

    Park, Hyo Seon; Lee, Minhyun; Kang, Hyuna; Hong, Taehoon; Jeong, Jaewook

    2016-01-01

    Highlights: • This study developed a new energy benchmark for office buildings. • Correlation analysis, decision tree, and analysis of variance were used. • The data from 1072 office buildings in South Korea were used. • As a result, six types of energy benchmarks for office buildings were developed. • The operational rating system can be improved by using the new energy benchmark. - Abstract: As improving energy efficiency in buildings has become a global issue today, many countries have adopted the operational rating system to evaluate the energy performance of a building based on the actual energy consumption. A rational and reasonable energy benchmark can be used in the operational rating system to evaluate the energy performance of a building accurately and effectively. This study aims to develop a new energy benchmark for improving the operational rating system of office buildings. Toward this end, this study used various data-mining techniques such as correlation analysis, decision tree (DT) analysis, and analysis of variance (ANOVA). Based on data from 1072 office buildings in South Korea, this study was conducted in three steps: (i) Step 1: establishment of the database; (ii) Step 2: development of the new energy benchmark; and (iii) Step 3: application of the new energy benchmark for improving the operational rating system. As a result, six types of energy benchmarks for office buildings were developed using DT analysis based on the gross floor area (GFA) and the building use ratio (BUR) of offices, and these new energy benchmarks were validated using ANOVA. To ensure the effectiveness of the new energy benchmark, it was applied to three operational rating systems for comparison: (i) the baseline system (the same energy benchmark is used for all office buildings); (ii) the conventional system (different energy benchmarks are used depending on the GFA, currently used in South Korea); and (iii) the proposed system (different energy benchmarks are

  20. Assessment of thermal load reduction due to the application of simple passive techniques in a house office building at the south of Libya

    International Nuclear Information System (INIS)

    Domanski, Roman; Azzain, Gassem

    2006-01-01

    The assessment of possible reduction of heating and cooling requirements of 300 m 2 house-office building has been presented in this paper, when simple Thermal Passive Techniques (TPT) have been applied to building's construction in Sebha city at the Libyan south. The known software for dynamic simulation (TRNSYS) has been used as an environment of digital experimentation for this study. A prototype represents the building has been constructed with the help of the available model of single thermal zone of TRNSYS (Type 19). The built-in ASHREA Transfer Function Method within this model has been used to calculate the heat flux through building's materials. Primarily, the thermal load on building's construction without TPTs has been evaluated under weather conditions of a Typical Meteorological Year (TMY) of Sebha city. Then, the building has been equipped with simple TPTs (such as the control of building materials, insulation, shading, infiltration and ventilation with windows resizing). This building was subjected to the same weather conditions and again the thermal load has been evaluated in order to report the percentage of reduction of thermal load. The simulation has been conducted successfully, where good assessment of reduction of annual heating and cooling demands in the building has been obtained. It is proved that, about (46%) of annual heating load and (48%) of annual cooling load can be reduced if suitable simple TPTs were incorporated in buildings.(Author)

  1. Software Prototype Design for Managing Housing and Communal Services in Apartment Buildings

    Directory of Open Access Journals (Sweden)

    Svetlana A.

    2018-03-01

    Full Text Available Introduction: The paper presents the disign and implementation of a computer program for the housing and utilities services. The Housing Code of the Russian Federation allows creating an apartment building council. The residents of a house choose the members this council to control providing services, manage an apartment building and represent their interests. The authors suggest using a special computer program for this purpose. Materials and Methods: The authors used the qualitative analysis of the data obtained from house bills and from the State housing and communal sector information system. The data processing and software development were performed through using the Ruby object-oriented language, the Ruby On Rails framework, the PostgreSQL database management system, the Slim templating, and Sass CSS extensions. Results: The authors developed a prototype software system to automate the activities of the apartment building council. This software helps to increase the quality of life of the apartment building residents. Discussion and Conclusions: This research provides an information framework for improving the quality of utilities services. The results of this study can be applied to the solution of many problems of housing and utilities sector.

  2. Application of BIM technology in green scientific research office building

    Science.gov (United States)

    Ni, Xin; Sun, Jianhua; Wang, Bo

    2017-05-01

    BIM technology as a kind of information technology, has been along with the advancement of building industrialization application in domestic building industry gradually. Based on reasonable construction BIM model, using BIM technology platform, through collaborative design tools can effectively improve the design efficiency and design quality. Vanda northwest engineering design and research institute co., LTD., the scientific research office building project in combination with the practical situation of engineering using BIM technology, formed in the BIM model combined with related information according to the energy energy model (BEM) and the application of BIM technology in construction management stage made exploration, and the direct experience and the achievements gained by the architectural design part made a summary.

  3. Forecasting uptake of retrofit packages in office building stock under government incentives

    International Nuclear Information System (INIS)

    Higgins, Andrew; Syme, Mike; McGregor, James; Marquez, Leorey; Seo, Seongwon

    2014-01-01

    As government and industry plan to reduce energy consumption in building stock, there is a need to forecast the uptake of retrofit packages across building stock over time. To address this challenge a diffusion model was set up and applied to office building stock across New South Wales (NSW) in Australia, accommodating a high spatial resolution and temporal capability for projecting uptake of technology packages characterised by multiple variables. Six retrofit packages were set up for the diffusion model, which ranged from inexpensive services and manuals through to mid-priced packages involving energy efficient T5 lighting and solar hot water through to expensive packages such as chilled beams and Solar PV. We evaluated the model using a base case and two policy programs, representing the Green Building Fund and Environmental Upgrade Agreements. These were recent incentive programs funded by the Australian government to accelerate the uptake of retrofit packages, by providing financial support to upfront expenditures and removing barriers to retrofit. By forecasting uptake of each retrofit package to 2032 under each program, we demonstrate how the model can be a valuable resource in tailoring expensive government programs and increasing their effectiveness. - Highlights: • Diffusion model for uptake of building retrofits. • Case study with New South Wales office buildings. • Forecast uptake of government policy programs

  4. Monitoring-based HVAC commissioning of an existing office building for energy efficiency

    International Nuclear Information System (INIS)

    Wang, Liping; Greenberg, Steve; Fiegel, John; Rubalcava, Alma; Earni, Shankar; Pang, Xiufeng; Yin, Rongxin; Woodworth, Spencer; Hernandez-Maldonado, Jorge

    2013-01-01

    Highlights: ► Demonstrated monitoring-based HVAC commissioning using an existing office building. ► Diagnosed various types of faulty operation in the HVAC system by trend data analyses. ► Identified a list of energy saving measures for the HVAC system. ► Quantified energy saving potential for each commissioning measure using calibrated energy simulation model. ► Achieved an actual energy saving of 10% after the implementations of cost-effective measures. -- Abstract: The performance of Heating, Ventilation and Air Conditioning (HVAC) systems may fail to satisfy design expectations due to improper equipment installation, equipment degradation, sensor failures, or incorrect control sequences. Commissioning identifies and implements cost-effective operational and maintenance measures in buildings to bring them up to the design intent or optimum operation. An existing office building is used as a case study to demonstrate the process of commissioning. Building energy benchmarking tools are applied to evaluate the energy performance for screening opportunities at the whole building level. A large natural gas saving potential was indicated by the building benchmarking results. Faulty operations in the HVAC systems, such as improper operations of air-side economizers, simultaneous heating and cooling, and ineffective optimal start, were identified through trend data analyses and functional testing. The energy saving potential for each commissioning measure is quantified with a calibrated building simulation model. An actual energy saving of 10% was realized after the implementations of cost-effective measures.

  5. Prototype of Emapps.com Environment as Agent for Building the Learning Communities

    Directory of Open Access Journals (Sweden)

    Vilma Butkute

    2010-04-01

    Full Text Available The Information Society and Education need to be combined in order to achieve successful active citizenship and economical development with a natural and mutual interdependency. Project eMapps.com game platform can be an example of cross- connected eLearning, mobile and life environment contribution to education. It can increase effectiveness of education both for educational needs in XXI Century and to create a basis for further research on ICT mediation in Information Society. The positive outcomes on learners motivation are explored by the scientific modelling of the future educational environment prototype as agent for building up the learning communities of common intelligence at internal, local and international level. The key finding of this paper is that an eMapps.com game platform prototype can be used to ensure that technology, pedagogy and social networking context are closely aligned in order to realise the educational stimulation in secondary education.

  6. Dynamic Analysis of an Office Building due to Vibration from Road Construction Activities

    Science.gov (United States)

    Chik, T. N. T.; Kamil, M. R. H.; Yusoff, N. A.; Ibrahim, M. H. W.

    2018-04-01

    Construction activities are widely known as one of the predominant sources of man-made vibrations that able to create nuisance towards any adjacent building, and this includes the road construction operations. Few studies conclude the construction-induced vibration may be harmful directly and indirectly towards the neighbouring building. This lead to the awareness of study the building vibration response of concrete masonry load bearing system and its vibrational performance towards the road construction activities. This study will simulate multi-storey office building of Sekolah Menengah Kebangsaan (SMK) Bandar Enstek at Negeri Sembilan by using finite element vibration analyses. The excitation of transient loads from ground borne vibrations which triggered by the road construction activities are modelled into the building. The vibration response was recorded during in-situ ambient vibration test by using Laser Doppler Vibrometer (LDV), which specifically performed on four different locations. The finite element simulation process was developed in the commercial FEA software ABAQUS. Then, the experimental data was processed and evaluated in MATLAB ModalV to assess the vibration criteria of the floor in building. As a result, the vibration level of floor in building is fall under VC-E curve which was under the maximum permissible level for office building (VC-ISO). The vibration level on floor is acceptable within the limit that have been referred.

  7. Performance Assessment of Maintenance Practices in Government Office Buildings: Case Study of Parcel E, Putrajaya

    Directory of Open Access Journals (Sweden)

    Awg Husaini A.I.

    2014-03-01

    Full Text Available Building maintenance practices must be taken into consideration by building facility managers or building owners. They involve daily operations to ensure that end users can work or live comfortably and safely. Through effective maintenance practices, the functions of the existing building facilities can be maintained and meet the needs of the building users. Maintenance practices must be effective in aspects such as planning, organization and supervision in order to maintain the building at a satisfactory level of performance all the time. A study was conducted on a Federal government office building in Parcel E, Putrajaya to determine the maintenance aspects of the management of the facility. To achieve the objectives of this study a questionnaire survey was used to obtain the required data. The outcomes indicate that the aspects of building maintenance practice and the effectiveness of the maintenance management in government office buildings can influence the satisfaction of the end user. However, some aspects of the current building maintenance practices seem to need improvements in order to enhance the building maintenance management. The recommendations of this study will help in the effective management of the facility and maintenance management practices.

  8. Multi-angled Façade System for Office Building Renovation

    DEFF Research Database (Denmark)

    Hannoudi, Loay Akram; Christensen, Jørgen Erik; Lauring, Michael

    renovating office buildings. The architectural potential is presented with the help of AutoCAD software. The energy efficiency and indoor climate are investigated and evaluated by using correlational research and simulation research methods with the software IDA ICE. From a functional perspective, the multi......-angled façade increases the area of the office room and provides more space. There are many potential aesthetic benefits provided by multi-angled façades such as improved optical and visual quality from inside the office room and the possibility for daylight penetration and a view to outside from one part...... compared to a renovated flat façade varies between 4.9 and 6.5 kWh/(m2.year), depending on the orientation of the façade. The increase in the office room area, when renovated with a multi-angled façade, is by 19%, while the increase of the yearly primary energy consumption (not area weighted), is by 4...

  9. European indoor air quality audit project in 56 office buildings

    NARCIS (Netherlands)

    Bluyssen, P.M.; Oliveira Fernandes, E. de; Groes, L.; Clausen, G.H.; Fanger, F.O.; Valbjorn, O.; Bernhard, C.A.; Roulet, C.A.

    1996-01-01

    A European project started at the end of 1992, in which, in addition to current methods, trained sensory panels were used to investigate office buildings all over Europe. The main aim of this EC-Audit was to develop assessment procedures and guid-ance on ventilation and source control, to help

  10. Buildings for the 21st Century, Summer 2001. Office of Building Technology, State and Community Programs (BTS) Newsletter

    International Nuclear Information System (INIS)

    Burgert, S.

    2001-01-01

    The Buildings for the 21st Century newsletter is produced by the Office of Building Technology, State and Community Programs and contains information on building programs, events, products, and initiatives, with a focus on energy efficiency and renewable energy. The summer issue includes information on technology roadmap initiatives, new energy computer simulation software, an educational CD with energy lessons for teachers, a CD with energy-saving tips, a study on the efficiency of clothes washers, a loan program in New York, and a calendar of meetings and conferences

  11. Buildings for the 21st Century, Summer 2001. Office of Building Technology, State and Community Programs (BTS) Newsletter

    Energy Technology Data Exchange (ETDEWEB)

    Burgert, S.

    2001-07-11

    The Buildings for the 21st Century newsletter is produced by the Office of Building Technology, State and Community Programs and contains information on building programs, events, products, and initiatives, with a focus on energy efficiency and renewable energy. The summer issue includes information on technology roadmap initiatives, new energy computer simulation software, an educational CD with energy lessons for teachers, a CD with energy-saving tips, a study on the efficiency of clothes washers, a loan program in New York, and a calendar of meetings and conferences.

  12. Design of an atrium for a passive-solar retrofit of an office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, J.L.; Hunn, B.D.

    1980-01-01

    The Los Alamos Scientific Laboratory (LASL) has proposed to retrofit one of its administrative office buildings with a solar atrium. A 334 m/sup 2/ courtyard will be enclosed with a roof-mounted system of clerestory windows to maximize winter solar gain. This sunspace will thermally buffer the adjoining offices and also will preheat air supplied to the building's conventional heating, ventilating, and air-conditioning (HVAC) system. The use of the DOE-2 building energy analysis computer program in the design of the solar atrium is described. The results of a series of simulations are reported detailing the tradeoffs inherent in the selection of an optimal glazing area, the maintenance of acceptable comfort levels within the sunspace, and intergration of passive-solar devices with the conventional HVAC system. Potential energy savings are also discussed.

  13. Optimization of annual energy demand in office buildings under the influence of climate change in Chile

    International Nuclear Information System (INIS)

    Rubio-Bellido, Carlos; Pérez-Fargallo, Alexis; Pulido-Arcas, Jesús A.

    2016-01-01

    Numerous studies about climate change have emerged in recent years because of their potential impact on many activities of human life, amongst which, the building sector is no exception. Changes in climate conditions have a direct influence on the external conditions for buildings and, thus, on their energy demand. In this context, computer aided simulation provides handy tools that help in assessing this impact. This paper investigates climate data for future scenarios and the effect on energy demand in office buildings in Chile. This data has been generated in the 9 climatic zones that are representative of the main inhabited areas, for the years 2020, 2050 and 2080. Predictions have been produced for the acknowledged A2 ‘medium-high’ Greenhouse Gases emissions GHG scenario, pursuant the Intergovernmental Panel on Climate Change (IPCC). The effect of climate change on the energy demand for office buildings is optimized by implementing the calculation procedure of ISO-13790:2008, based on iterations of its envelope and form. As a result, this research clarifies how future climate scenarios will affect the energy demand for different types of office buildings in Chile, and how their shape and enclosure can be optimized. - Highlights: • Forecast of 9 Chilean climate zones under Greenhouse Gases Scenario A2. • Influence of envelope and form on future energy demand in office buildings. • Multiple iterations on Form Ratio (FR) and Window-to-Wall Ratio (WWR). • Optimization in early stages of design considering global warming.

  14. Energy savings due to daylight and artificial lighting integration in office buildings in hot climate

    Energy Technology Data Exchange (ETDEWEB)

    Al-Ashwal, Nagib T. [Sana' a University, Sana' a (Yemen); Budaiwi, Ismail M. [King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia)

    2011-07-01

    Reducing energy consumption while maintaining acceptable environmental quality in buildings has been a challenging task for building professionals. In office buildings, artificial lighting systems are a major consumer of energy and can significantly contribute to building cooling load. Furthermore, although reliable, artificial lighting does not necessarily provide the required quality of lighting. Significant improvement in lighting quality and energy consumption can be achieved by proper integration of daylight and artificial lighting. The objective of this study is to investigate the energy performance of office buildings resulting from daylight and artificial lighting integration in hot climates. A parametric analysis is conducted to find the impact of different window design parameters, including window area, height and glazing type, on building energy performance. Results have shown that as much as 35% reduction in lighting energy consumption and 13% reduction in total energy consumption can be obtained when proper daylighting and artificial lighting integration is achieved.

  15. Psychological distress, job dissatisfaction, and somatic symptoms in office workers in 6 non-problem buildings in the Midwest.

    Science.gov (United States)

    Black, Donald W; Manlick, Christopher F; Fuortes, Laurence J; Stein, Matthew A; Subramanian, P; Thorne, Peter S; Reynolds, Stephen J

    2014-08-01

    Researchers examined office worker characteristics and reports of non-specific somatic symptoms in 6 non-problem buildings in the Midwestern United States. We assessed office workers for demographic characteristics and somatic symptoms that occurred in the workplace. Sampling was conducted over a 1-week period in each building over 4 seasons. Our team administered the Medical Outcome Survey questionnaire, the Brief Symptom Inventory, and the Job Content Questionnaire to individuals at each site, comparing office workers reporting no symptoms to those reporting ≥4 symptoms. Self-reported nonspecific somatic symptoms were frequent in office workers in non-problem buildings. High symptom levels were associated with younger age, female sex, psychological distress, impaired quality of life, and poor job satisfaction. The findings suggest that office workers frequently report somatic symptoms they believe are related to the workplace even in buildings considered non-problematic. People with high symptom levels perceived as related to the workplace are psychologically distressed, have impaired quality of life, and feel dissatisfied and powerless in the workplace.

  16. Revealing Occupancy Patterns in Office Buildings Through the use of Annual Occupancy Sensor Data

    Energy Technology Data Exchange (ETDEWEB)

    Carlos Duarte; Kevin Van Den Wymelenberg; Craig Rieger

    2013-06-01

    Energy simulation programs like DOE-2 and EnergyPlus are tools that have been proven to aid with energy calculations to predict energy use in buildings. Some inputs to energy simulation models are relatively easy to find, including building size, orientation, construction materials, and HVAC system size and type. Others vary with time (e.g. weather and occupancy) and some can be a challenge to estimate in order to create an accurate simulation. In this paper, the analysis of occupancy sensor data for a large commercial, multi-tenant office building is presented. It details occupancy diversity factors for private offices and summarizes the same for open offices, hallways, conference rooms, break rooms, and restrooms in order to better inform energy simulation parameters. Long-term data were collected allowing results to be presented to show variations of occupancy diversity factors in private offices for time of day, day of the week, holidays, and month of the year. The diversity factors presented differ as much as 46% from those currently published in ASHRAE 90.1 2004 energy cost method guidelines, a document referenced by energy modelers regarding occupancy diversity factors for simulations. This may result in misleading simulation results and may introduce inefficiencies in the final equipment and systems design.

  17. A cash flow model of development activity and the scope for energy savings. [Commercial office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Leifer, D [Queensland Univ., St. Lucia (AU). Dept. of Architecture

    1991-01-01

    When proposing energy saving measures to the developers of large commercial office projects, it is necessary to appreciate what the developers' goals and perceptions are. This paper looks at a simple cash-flow model of development activity, and illustrates the potential for energy savings with reference to some data from two major Australian cities. This data was collected between July and November 1989 by surveys which were carried out on the basic design of 26 of the tallest Brisbane commercial office buildings. This survey followed an extensive investigation into the premises needs of modern office building tenants in Brisbane, in which over 200 CBD tenants were questioned. This investigation showed that there was an increasing need for air conditioning capacity and electrical power; greater tendencies for ''after hours'' office work; a desire for larger floor-plates to cater for expanding tenant organizations, and the emergence of ''professional tenants''. These observations have been documented elsewhere in the orbit reports amongst others. The buildings surveyed represent 60% of the estimated Brisbane central business district (CBD) office stock of area 1,256,000 m{sup 2}. (author).

  18. The Analysis of Applying Different Coolants for Cooling Systems in the Office Building

    Directory of Open Access Journals (Sweden)

    Rasa Kanapienytė

    2011-12-01

    Full Text Available The paper analyzes air conditioning systems of different coolants on the basis of an example of a typical office building. Depending on the type of a coolant fan coil unit, active chilled beams, variable refrigerant volumes and air cooling systems were designed. The article suggests hydraulic and aerodynamic calculations and evaluates initial investments, energy expenditures and operating costs of the compared systems. Considering economic calculations, the pay-back time of the systems was assessed and the sensitivity analysis of electricity prices was carried out. The results of the conducted investigation show the most appropriate analysed system for office buildings taking into account the efficient use of electricity and initial investments.Article in Lithuanian

  19. A research on indoor environments of an office building by occupants' subjective evaluation

    International Nuclear Information System (INIS)

    Moon, S.W.; Kim, T.W.; Hong, W.H.

    2008-01-01

    Since modern workers spend more than 80 per cent of their time in indoor environments, it is important to make a comfortable indoor environment in order to maintain occupational health and to improve work efficiency and productivity. Not only are new offices bigger than ever before, the internal heat and air are controlled by a central air conditioning system, which do not allow occupant control. This study evaluated indoor environments of office buildings in an effort to understand how the indoor environment influences work efficiency. The study involved the use of a survey questionnaire to obtain occupants' subjective evaluation of indoor working environments of an office building in terms of thermal comfort, lighting, noise and air quality. The survey results indicated that the indoor environment interrupts the work of many workers. Neck, eye, skin and nasal symptoms were found to be the symptoms most related to the indoor environment, with temperature and humidity posing the greatest challenge. 9 refs., 9 tabs., 7 figs

  20. Energy efficient glazed office buildings with double skin facades in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Eriksson, Bo; Blomsterberg, Aake (WSP Environmental (Sweden)). e-mail: bo.eriksson@wspgroup.se

    2009-07-01

    Many modern office buildings have highly glazed facades. Their energy efficiency and indoor climate are, however, being questioned. Therefore more and more of these buildings are being built with double skin facades, which can provide improvements: A project BESTFACADE, with participants from Austria, Germany, Greece, Portugal (France) and Sweden, was therefore funded by the European Commission (IEE) to actively promote well-performing concepts of double skin facades. Included were best practice guidelines, which included the determination of the energy use and thermal comfort by simulations for warm, mild and cold climates. The main conclusion is that the choice of glazing properties such as glazing area, U-value (thermal transmittance) of the glazing and its profiles, g-value (the total solar energy transmittance) of the glazing and type of solar shading are crucial for the energy and indoor climate performance of an office. The choice of control strategies for ventilation of the cavity and operation of solar shading are crucial. The above choices are very dependant on the climate. Choices which are optimal in a cold climate, will not work very well in a warm climate, and vice versa. From an energy and indoor climate point of view a highly glazed office with a double skin facade is often preferred to a single

  1. Thermal and lighting perception in four fully glazed office buildings in Santiago, Chile

    Directory of Open Access Journals (Sweden)

    Claudio Vásquez

    2013-12-01

    Full Text Available Corresponding author: Claudio Vásquez, School of Architecture, Catholic University of Chile. 1916 El Comendador str. Providencia, Santiago, ZIP: 7530091, Chile. Tel.: +56 9 92826305; E-mail: clvasque@uc.cl This paper is part of a general research project whose main objective is to establish a baseline for post-occupancy energy consumption and indoor environmental quality for office buildings in Santiago, Chile. This study aims at understanding how architectonical variables relate to, and can even determine, user comfort perception. Thus, one-year continuous monitoring in several floors at four office buildings was performed and seasonal surveys were completed. Survey participants were asked a series of questions regarding spatial orientation and comfort perception in their workspace. The data from the comfort survey and onsite measurements such as season of the year, case study, type of workspace and possibility of an outdoor view from the workstation were contrasted with the components obtained by a Principal Component Analysis (PCA. Three components were selected from the PCA, and three Maps of Perception (MP were produced. These maps were then analyzed and interpreted so as to obtain information on the general perception of thermal and lighting comfort at workspaces within several office buildings in Santiago.

  2. Towards a new procedure for identifying causes of health and comfort problems in office buildings

    NARCIS (Netherlands)

    Bluyssen, P.M.; Fossati, S.; Mandin, C.; Cattaneo, A.; Carrer, P.

    2012-01-01

    In the European project OFFICAIR a procedure has been prepared for the inventory and identification of associations between possible characteristics of European modern offices (building, sources and events) and health and comfort of office workers, via a questionnaire and a checklist including

  3. Energy edge post-occupancy evaluation project: the Hollywood Office Building, Portland, Oregon

    Energy Technology Data Exchange (ETDEWEB)

    1990-06-01

    The Hollywood Office Park Building Survey for the Energy Post- Occupancy Project was administered to nine building occupants. The nine respondents answered the questions which rated building features in the areas of (1) thermal factors; (2) air quality; (3) lighting; (4) acoustics; and, (5) overall workspace satisfaction. In addition to rating these ambient environmental features, these respondents also rated their satisfaction of various functional and aesthetic features and specific kinds of workspaces. Data was also collected on heath characteristics and occupational demographics of the respondents. No analysis is made of the survey findings which are reported in graphic format. 15 figs. (BN)

  4. The Analysis Of Capillary Tube System For Office Buildings In Africa. A Case Study Of Nigerian And Namibian Climate

    Directory of Open Access Journals (Sweden)

    Sulaiman Muhammad kabir

    2017-01-01

    Full Text Available The change in climate and the rise in energy rates have become a necessary consideration in the construction industry which has made architects and engineers to arise with improved building design concepts. A focus on creating a comfortable indoor climate in office buildings ensures productive working conditions for the users and reduces global warming. Specific climatic design principles are often disregarded when designing to create a comfortable indoor climate. Sustainable design methods in buildings has been replicated from one zone to another zone without adjustments which results to buildings that do not provide adequate comfort. Capillary tube system is used to provide a comfortable indoor climate for office buildings making an interesting use of geothermal energy. This paper aims to explain its principle using geothermal energy and the effect of climate on the use of this system in office buildings in Africa. A case study of Lagos state lying on the coast of the Atlantic Ocean which is challenged with high rise in sea level as a result of global warming in Nigeria and Windhoek in Namibia is to be taken into consideration as the business hub of its country. These regions comprises of many office buildings to facilitate the countries trade internationally and locally.

  5. Close encounters of the prototype kind

    CERN Multimedia

    2005-01-01

    CERN is building a new control centre for the operation of its entire accelerator complex and technical infrastructure. The prototype console for the new centre has just been installed and tested. Close encounters of the prototype kind CERN is building a new control centre for the operation of its entire accelerator complex and technical infrastructure. The prototype console for the new centre has just been installed and tested. The prototype of the control consoles that will be at the heart of the future CERN Control Centre (CCC) has just been installed in the Roy Billinge Room in Building 354. Until now, there have been four separate control rooms for the CERN accelerators and technical infrastructure. The CCC, which will be located on the Prévessin site, will bring them all together in a single room. The Centre will consist of 40 consoles for four different areas (LHC, SPS, PS complex and technical infrastructure). The prototype was tested by the technicians for a month. Following installation and con...

  6. Plug-Load Control and Behavioral Change Research in GSA Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Metzger, I.; Cutler, D.; Sheppy, M.

    2012-10-01

    The U.S. General Services Administration (GSA) owns and leases over 354 million square feet (ft2) of space in over 9,600 buildings [1]. GSA is a leader among federal agencies in aggressively pursuing energy efficiency (EE) opportunities for its facilities and installing renewable energy (RE) systems to provide heating, cooling, and power to these facilities. According to several energy assessments of GSA's buildings conducted by the National Renewable Energy Laboratory (NREL), plug-loads account for approximately 21% of the total electricity consumed within a standard GSA Region 3 office building. This study aims to provide insight on how to effectively manage plug-load energy consumption and attain higher energy and cost savings for plug-loads. As GSA improves the efficiency of its building stock, plug-loads will become an even greater portion of its energy footprint.

  7. Cost-benefit analysis of improved air quality in an office building

    DEFF Research Database (Denmark)

    Djukanovic, R.; Wargocki, Pawel; Fanger, Povl Ole

    2002-01-01

    A cost-benefit analysis of measures to improve air quality in an existing air-conditoned office building (11581 m2, 864 employees) was carried out for hot, temperate and cold climates and for two operating modes: Variable Air Volume (VAV) with economizer; and Constant Air Volume (CAV) with heat...... recovery. The annual energy cost and first cost of the HVAC system were calculat4ed using DOE 2.1E for different levels of air quality (10-50% dissatisfied). This was achieved by changing the outdoor air supply rate and the pollution loads. Previous studies have documented a 1.1% increase in office...

  8. Building automation and perceived control : a field study on motorized exterior blinds in Dutch offices

    NARCIS (Netherlands)

    Meerbeek, B.W.; te Kulve, Marije; Gritti, T.; Aarts, M.P.J.; Loenen, van E.J.; Aarts, E.H.L.

    2014-01-01

    As a result of the technological advances and increasing focus on energy efficient buildings, simple forms of building automation including automatic motorized blinds systems found their ways into today's office environments. In a five-month field study, qualitative and quantitative methods were

  9. Data management for biofied building

    Science.gov (United States)

    Matsuura, Kohta; Mita, Akira

    2015-03-01

    Recently, Smart houses have been studied by many researchers to satisfy individual demands of residents. However, they are not feasible yet as they are very costly and require many sensors to be embedded into houses. Therefore, we suggest "Biofied Building". In Biofied Building, sensor agent robots conduct sensing, actuation, and control in their house. The robots monitor many parameters of human lives such as walking postures and emotion continuously. In this paper, a prototype network system and a data model for practical application for Biofied Building is pro-posed. In the system, functions of robots and servers are divided according to service flows in Biofield Buildings. The data model is designed to accumulate both the building data and the residents' data. Data sent from the robots and data analyzed in the servers are automatically registered into the database. Lastly, feasibility of this system is verified through lighting control simulation performed in an office space.

  10. A simplified model of dynamic interior cooling load evaluation for office buildings

    International Nuclear Information System (INIS)

    Ding, Yan; Zhang, Qiang; Wang, Zhaoxia; Liu, Min; He, Qing

    2016-01-01

    Highlights: • The core interior disturbance was determined by principle component analysis. • Influences of occupants on cooling load should be described using time series. • A simplified model was built to evaluate dynamic interior building cooling load. - Abstract: Predicted cooling load is a valuable tool for assessing the operation of air-conditioning systems. Compared with exterior cooling load, interior cooling load is more unpredictable. According to principle components analysis, occupancy was proved to be a typical factor influencing interior cooling loads in buildings. By exploring the regularity of interior disturbances in an office building, a simplified evaluation model for interior cooling load was established in this paper. The stochastic occupancy rate was represented by a Markov transition model. Equipment power, lighting power and fresh air were all related to occupancy rate based on time sequence. The superposition of different types of interior cooling loads was also considered in the evaluation model. The error between the evaluation results and measurement results was found to be lower than 10%. In reference to the cooling loads calculated by the traditional design method and area-based method in case study office rooms, the evaluated cooling loads were suitable for operation regulation.

  11. Energy and comfort performance evaluation after renovation of an office building

    Energy Technology Data Exchange (ETDEWEB)

    Renzi, V.; Burgun, F. [Inst. National de l' Energie Solaire, Le Bourget du Lac (France)

    2009-07-01

    Buildings constitute 42.5 per cent of the energy consumption in Europe. As such, the building sector represents a high potential for innovation in terms of reducing global energy consumption. Since existing buildings represent a large part of the built environment, refurbishment is an important issue to consider. However, efficient processes of renovation must be well defined. France's National Institute of Solar Energy has developed a methodology to reduce consumption of primary energy use and decrease greenhouse gas emissions in the built environment, while increasing user comfort. The methodology places much emphasis on the health and comfort of occupants from the very beginning of the process. The methodology was developed to make the building renovation process more efficient by elaborating generic guidelines and tools. In this study, an office building from the 1970s was refurbished and monitored for both energy performance and comfort. The objective was to better understand the technological and psychosocial aspects involved in refurbishing an old building. Measurements were compared with the perception of the occupants. The impacts of human interaction on the building behaviour was also evaluated. 6 refs., 1 tab., 4 figs.

  12. Symptoms prevalence among office workers of a sealed versus a non-sealed building: associations to indoor air quality.

    Science.gov (United States)

    Rios, José Luiz de Magalhães; Boechat, José Laerte; Gioda, Adriana; dos Santos, Celeste Yara; de Aquino Neto, Francisco Radler; Lapa e Silva, José Roberto

    2009-11-01

    An increasing number of complaints related to time spent in artificially ventilated buildings have been progressively reported and attributed, at least in part, to physical and chemical exposures in the office environment. The objective of this research was to investigate the association between the prevalence of work-related symptoms and the indoor air quality, comparing a sealed office building with a naturally ventilated one, considering, specially, the indoor concentration of TPM, TVOCs and the main individual VOCs. A cross-sectional study was performed to compare the prevalence of sick building syndrome (SBS) symptoms among 1736 office workers of a sealed office building and 950 of a non-sealed one, both in Rio de Janeiro's downtown. The prevalence of symptoms was obtained by a SBS standardized questionnaire. The IAQ of the buildings was evaluated through specific methods, to determine the temperature, humidity, particulate matter and volatile organic compound (VOC) concentrations. Upper airways and ophthalmic symptoms, tiredness and headache were highly prevalent in both buildings. Some symptoms were more prevalent in the sealed building: "eye dryness" 33.3% and 27.1% (p: 0.01); "runny nose" 37.3% and 31.3% (p: 0.03); "dry throat" 42% and 36% (p: 0.02); and "lethargy" 58.5% and 50.5% (p: 0.03) respectively. However, relative humidity and indoor total particulate matter (TPM) concentration as well as total volatile organic compounds (TVOCs) were paradoxically greater in the non-sealed building, in which aromatic compounds had higher concentration, especially benzene. The analysis between measured exposure levels and resulting symptoms showed no association among its prevalence and TPM, TVOCs, benzene or toluene concentration in none of the buildings. Other disregarded factors, like undetected VOCs, mites, molds and endotoxin concentrations, may be associated to the greater prevalence of symptoms in the sealed building.

  13. A Non-linear Stochastic Model for an Office Building with Air Infiltration

    DEFF Research Database (Denmark)

    Thavlov, Anders; Madsen, Henrik

    2015-01-01

    This paper presents a non-linear heat dynamic model for a multi-room office building with air infiltration. Several linear and non-linear models, with and without air infiltration, are investigated and compared. The models are formulated using stochastic differential equations and the model...

  14. Architectural qualities of Danish office buildings built between 1960 and 1980, seen in a contemporary sustainable perspective

    DEFF Research Database (Denmark)

    Hannoudi, L.; Lauring, M.; Christensen, Jørgen Erik

    2016-01-01

    This study is about evaluating the past and present architectural quality of office buildings built between1960 and 1980 in Denmark. The evaluation will focus on the expression of these buildings in relation to their context, combined with the present sustainable performance of the buildings...

  15. IMPACT ON THE APPLICATION OF INSULATION IN BUILDINGS TO ACHIEVE THERMAL COMFORT (A CASE STUDY: LAUSER OFFICE BUILDING IN BANDA ACEH

    Directory of Open Access Journals (Sweden)

    Nova Purnama Lisa

    2014-12-01

    Full Text Available From the results of research studies on the impact of the use of insulation in buildings, reducing solar radiation on buildings to improve indoor comfort by applying the Principles of radiation reduction in buildings naturally using insulation application that serves as an insulator against the building materials, use of thermal insulation in particular mounted on the roof of the building and the walls are located on second floor and the third floor Lauser office building, Calculate the cooling load for each room that was on second floor and the third floor based on the geographical location or position of the building, climate data, building material data , and the intensity of the spatial characteristics which include lighting, solar radiation, user activity and electrical appliances being used. The calculation is done with the help of Ecotech v.5, 2011. The location and position on the third floor of a building with a flat roof cast concrete, so that the heat absorbed by the platform, and two times greater than the amount of heat radiation is absorbed by the material in the direction of the light falling the sun is at an angle <30°C. The simulation results on the building with the addition of thermal insulation on all walls and the roof of the inside of the foam material ultrafolmadehid, without changing the model building and similar activities in accordance with the existing condition and the condition of the room using the air conditioner at a temperature of 18-26°C, indicating a decrease in cooling load signifinikan in any space reaches 40% of the total cooling load required on the lauser office building. Comparing the simulation results Ecotech temperature v.5 2011 with field measurements as a validation of the simulation results in order to achieve thermal comfort in buildings and can menggurangi use energy consumption in buildings and can be used as a reference in planning space-based conditioning systems energy efficient.

  16. Solution Prototype

    DEFF Research Database (Denmark)

    Efeoglu, Arkin; Møller, Charles; Serie, Michel

    2013-01-01

    This paper outlines an artifact building and evaluation proposal. Design Science Research (DSR) studies usually consider encapsulated artifact that have relationships with other artifacts. The solution prototype as a composed artifact demands for a more comprehensive consideration in its systematic...... environment. The solution prototype that is composed from blending product and service prototype has particular impacts on the dualism of DSR’s “Build” and “Evaluate”. Since the mix between product and service prototyping can be varied, there is a demand for a more agile and iterative framework. Van de Ven......’s research framework seems to fit this purpose. Van de Ven allows for an iterative research approach to problem solving with flexible starting point. The research activity is the result between the iteration of two dimensions. This framework focuses on the natural evaluation, particularly on ex...

  17. Prevalence and risk factors for Sick Building Syndrome among Italian correctional officers: A pilot study

    OpenAIRE

    Francesco Chirico; Giuseppe Ferrari; Giuseppe Taino; Enrico Oddone; Ines Giorgi; Marcello Imbriani

    2017-01-01

    Introduction: Over the past two decades, numerous studies on indoor air and the Sick Building Syndrome (SBS) have been conducted, mostly in office environments. However, there is little knowledge about SBS in police officers. This study was aimed to fill this gap. Methods: A cross-sectional questionnaire survey was conducted in 2016 at the Triveneto Penitentiary Center, Northern Italy. Chi-square was used to test the difference of prevalence between office workers (OWs) and correctional of...

  18. The potential for distributed generation in Japanese prototype buildings: A DER-CAM analysis of policy, tariff design, building energy use, and technology development (English Version)

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Nan; Marnay, Chris; Firestone, Ryan; Gao, Weijun; Nishida, Masaru

    2004-10-15

    global optimization, albeit idealized, that shows how the necessary useful energy loads can be provided for at minimum cost by selection and operation of on-site generation, heat recovery, cooling, and efficiency improvements. This study examines five prototype commercial buildings and uses DER-CAM to select the economically optimal DER system for each. The five building types are office, hospital, hotel, retail, and sports facility. Each building type was considered for both 5,000 and 10,000 square meter floor sizes. The energy consumption of these building types is based on building energy simulation and published literature. Based on the optimization results, energy conservation and the emissions reduction were also evaluated. Furthermore, a comparison study between Japan and the U.S. has been conducted covering the policy, technology and the utility tariffs effects on DER systems installations. This study begins with an examination of existing DER research. Building energy loads were then generated through simulation (DOE-2) and scaled to match available load data in the literature. Energy tariffs in Japan and the U.S. were then compared: electricity prices did not differ significantly, while commercial gas prices in Japan are much higher than in the U.S. For smaller DER systems, the installation costs in Japan are more than twice those in the U.S., but this difference becomes smaller with larger systems. In Japan, DER systems are eligible for a 1/3 rebate of installation costs, while subsidies in the U.S. vary significantly by region and application. For 10,000 m{sup 2} buildings, significant decreases in fuel consumption, carbon emissions, and energy costs were seen in the economically optimal results. This was most noticeable in the sports facility, followed the hospital and hotel. This research demonstrates that office buildings can benefit from CHP, in contrast to popular opinion. For hospitals and sports facilities, the use of waste heat is particularly

  19. 76 FR 1192 - Standard on Powered Platforms for Building Maintenance; Extension of the Office of Management and...

    Science.gov (United States)

    2011-01-07

    ...] Standard on Powered Platforms for Building Maintenance; Extension of the Office of Management and Budget's... specified in its Standard on Powered Platforms for Building Maintenance (29 CFR 1910.66). DATES: Comments... Building Maintenance (29 CFR 1910.66). The Agency is requesting to retain its current burden hour total of...

  20. The costs and benefits of using daylight guidance to light office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Mayhoub, M.S.; Carter, D.J. [School of Architecture, University of Liverpool (United Kingdom)

    2011-03-15

    Daylight guidance systems are linear devices that channel daylight into the core of a building. This paper analyses costs and benefits of using the two main classes of daylight guidance to light offices as an alternative to conventional electric lighting. The work demonstrates that daylight guidance is generally not economical using conventionally accepted measures of both cost and benefit. It is shown that if intangible benefits associated with the delivery of daylight to offices are included in an analysis, a more favourable balance of cost and benefit is obtained. The implications of this for practical use of the systems are discussed. (author)

  1. Building-Related Symptoms, Energy, and Thermal Control in the Workplace: Personal and Open Plan Offices

    Directory of Open Access Journals (Sweden)

    Sally S. Shahzad

    2016-04-01

    Full Text Available This study compared building-related symptoms in personal and open plan offices, where high and low levels of control over the thermal environment were provided, respectively. The individualized approach in Norway provided every user with a personal office, where they had control over an openable window, door, blinds, and thermostat. In contrast, the open plan case studies in the United Kingdom provided control over openable windows and blinds only for limited occupants seated around the perimeter of the building, with users seated away from the windows having no means of environmental control. Air conditioning was deployed in the Norwegian case study buildings, while displacement ventilation and natural ventilation were utilized in the British examples. Field studies of thermal comfort were applied with questionnaires, environmental measurements, and interviews. Users’ health was better in the Norwegian model (28%, while the British model was much more energy efficient (up to 10 times. The follow-up interviews confirmed the effect of lack of thermal control on users’ health. A balanced appraisal was made of energy performance and users’ health between the two buildings.

  2. Occupancy pattern in office buildings : consequences for HVAC system design and operation

    Energy Technology Data Exchange (ETDEWEB)

    Halvarsson, Johan

    2011-07-01

    The main objectives with the work presented in this thesis have been: (a) to contribute to an increased understanding of the consequences that the occupancy pattern can have on the indoor climate and for Heating, Ventilation and Air Conditioning (HVAC) system design and operation; and (b) to investigate how typical occupancy patterns can look like in office buildings. The occupancy pattern in an office is a function of the floor layout of the building, and the user organisation(s) occupying it and their way of working. The combination of these two, will decide how the users occupy the building, which in turn is an important design prerequisite/constraint for the HVAC system design process. There are many assessments related to indoor climate and HVAC that involve considerations of the occupancy pattern, reaching from estimates of internal heat and pollution loads to deciding on an appropriate control strategy of HVAC systems, or estimating the energy saving potential with demand controlled ventilation. A few numerical measures have been used to describe different aspects of the occupancy pattern. The zone based occupancy factor (OFz) expresses the ratio between the number of occupied sub-zones/rooms in a zone and the total number of sub-zones/rooms in the zone. OFz does not take the number of people into account, only whether a sub-zone/room is occupied or unoccupied. OFz can be used both to express instantaneous occupancy levels and averages over time. Superscript is used to specify the time, or time period, that the measure refers to. For instance, 06 18,wd OFz means the average OFz between 6 a.m. and 6 p.m. on working days, while the 95th percentile of OFz6{sub 1}8,wd , means the 95th percentile of all instantaneous values (one or five minute averages in the case studies) of OFz that have occurred during the same time period. The utilisation rate (UR) expresses the fraction of time that a room is occupied, within a specific time period. It is important to

  3. Overall efficiency of office buildings; Gesamtenergieeffizienz von Buero-Bauten. Optimierung des Heizwaermebedarfs vs. Optimierung der Gesamtenergieeffizienz - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Gadola, R.; Menti, U.-P.; Pluess, I.; Klauz, S. [Hochschule Luzern - Technik und Architektur Zentrum fuer Integrale Gebaeudetechnik (ZIG), Horw (Switzerland); Menard, M. [Lemon Consult GmbH, Zuerich (Switzerland)

    2010-04-15

    This final report for the Swiss Federal Office of Energy (SFOE) takes a look at the overall efficiency of office buildings. The optimisation of heating requirements and the optimisation of overall energy efficiency are compared. The trend towards compact, very well insulated buildings as propagated by current energy regulations is examined in the light of other energy-saving aspects such as air-conditioning requirements and lighting. The Swiss 'Minergie-P' standard that calls for extremely low energy consumption is discussed in this connection. Primary energy requirements and greenhouse gas emissions are discussed and sensitivity analyses for various factors affecting buildings are looked at. Also 'grey energy' in materials is considered.

  4. Retrofits for Energy Efficient Office Buildings: Integration of Optimized Photovoltaics in the Form of Responsive Shading Devices

    Directory of Open Access Journals (Sweden)

    Hardi K. Abdullah

    2017-11-01

    Full Text Available This study presents a retrofit strategy: integrating optimized photovoltaics (PV in the form of responsive shading devices using a dual-axis solar tracking system. A prototype-based model was fabricated to compare the efficiency of PV in this implementation with the conventional fixed installation. The office building, T1 Empire World in Erbil, was selected as a retrofit case study and for the application of the proposed integration system. In order to assess the effectiveness of the proposed retrofit method, the energy performance of the base case is simulated to be compared later with the energy performance simulations after the integration technique. The amount of generated electricity from the PV surfaces of the integrated shading elements is calculated. The energy simulations were performed using OpenStudio® (NREL, Washington, DC, USA, EnergyPlusTM (NREL, Washington, DC, USA, and Grasshopper/ Ladybug tools in which the essential results were recorded for the baseline reference, as well as the energy performance of the retrofitted building. The results emphasize that the PV-integrated responsive shading devices can maximize the efficiency of PV cells by 36.8% in comparison to the fixed installation. The integrated system can provide approximately 15.39% of the electricity demand for operating the building. This retrofit method has reduced the total site energy consumption by 33.2% compared to the existing building performance. Total electricity end-use of the various utilities was lowered by 33.5%, and the total natural gas end-use of heating demand was reduced by 30.9%. Therefore, the percentage reduction in electricity cooling demand in July and August is 42.7% due to minimizing the heat gain in summer through blocking the sun’s harsh rays from penetrating into interior spaces of the building. In general, this system has multiple benefits, starting with being extremely efficient and viable in generating sustainable alternative energy

  5. The methodology of technical due diligence report preparation for an office, residential and industrial buildings

    Directory of Open Access Journals (Sweden)

    Kutera Beata

    2016-01-01

    Full Text Available The methodology of a technical due diligence preparation is presented in this paper. It comprises actions that have to be undertaken prior to formal agreement with party ordering due diligence preparation, building a team of consultants, data collecting, preparing analysis and handing over the report to the client. All important issues were described and supported by examples. As there are many types of building objects this paper is limited to office, residential and industrial buildings.

  6. [Hygienic assessment of a recirculatory combined air-conditioning extract-and-input system in office building].

    Science.gov (United States)

    Malysheva, A G; Abramov, E G

    2006-01-01

    The high concentrations of lead were reveled in the air and dust of some premises and on the filters of a combined air-conditioning extract-and-input system in the high-rise office buildings located in the ecologically lead favorable environment. The dust content of lead in some premises on the first floors dust was as high as 200 mg/kg, which was more than 6 times higher than that in the soil at the highway near the office buildings. The use of new technologies and devices for cleaning and optimizing the air in the premises requires analytical studies to assess the quality of the environment, by taking into account the optimal conditions of their operation.

  7. Modeling of a Novel Low-Exergy System for Office Buildings with Modelica

    DEFF Research Database (Denmark)

    Maccarini, Alessandro; Afshari, Alireza; Hultmark, Göran

    2016-01-01

    This paper aims to investigate the thermal behavior of a novel low-exergy system for office buildings. The main characteristic of the system is its ability to provide simultaneous heating and cooling by operating one water circuit. Inlet water temperature of about 22 °C is delivered to all...... the thermal zones in the building, no matter whether a single zone needs heating or cooling. This approach clearly differs from conventional systems where simultaneous heating and cooling is provided by two separated water circuits. A detailed model of the novel system was developed with Dymola, a modeling...

  8. Indoor air quality and occupant satisfaction in five mechanically and four naturally ventilated open-plan office buildings

    DEFF Research Database (Denmark)

    Hummelgaard, J.; Juhl, P.; Saebjornsson, K.O.

    2007-01-01

    Occupant responses and indoor environment characteristics were recorded and compared in five mechanically and four naturally ventilated open-plan office buildings by using a simple approach that enabled us to survey many buildings simultaneously. All occupant responses were obtained during one...

  9. Sensitivity analysis of water consumption in an office building

    Science.gov (United States)

    Suchacek, Tomas; Tuhovcak, Ladislav; Rucka, Jan

    2018-02-01

    This article deals with sensitivity analysis of real water consumption in an office building. During a long-term real study, reducing of pressure in its water connection was simulated. A sensitivity analysis of uneven water demand was conducted during working time at various provided pressures and at various time step duration. Correlations between maximal coefficients of water demand variation during working time and provided pressure were suggested. The influence of provided pressure in the water connection on mean coefficients of water demand variation was pointed out, altogether for working hours of all days and separately for days with identical working hours.

  10. The Minimum Impact House : Applications of the Frankfurt Prototype for sustainable building in Cities of the European Rhine Region

    NARCIS (Netherlands)

    Drexler, H.; Jauslin, D.; Curiel, F.

    2010-01-01

    The Minimum Impact House in Frankfurt am Main is a sustainable solution for low cost living within city centers - a prototype typology with minimal footprint, built on a leftover urban space. The planning process itself became part of a scientific study. The ecological advantages of building in the

  11. Realization of a demand response in office-buildings; Umsetzung eines Lastmangements in Buerogebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Jungwirth, Johannes; Berger, Christian [TU Muenchen (Germany). Lehrstuhl fuer Energiewirtschaft und Anwendungstechnik; Roessel, Timm [TU Muenchen (Germany). Lehrstuhl fuer Bauklimatik und Haustechnik

    2011-07-01

    Due to the mostly fluctuating feed-in characteristics, the strong expansion of renewable energy producers lets expect a paradigm shift in the structure of the power supply concept. The integration of renewables into the electricity grid requires new ways to compensate the temporal discrepancy between production and consumption. Such a load management or demand response requires electrical devices that can be varied with time in their mode of operation. The results of a feasibility study show that amongst other things a lot of electric devices being suitable for the implementation of the load management are present in office buildings and administration buildings. As an already existing communication structure one may refer to the equipment automation for the control of the individual devices. In order to realize the existing potentials, an innovative control strategy based on the existing hardware is necessary. This control strategy may adapt the mode of operation to an external signal. In order to allow a realistic development of such control strategies, a hardware-in-the-loop (HIL) testing environment was created which allows a development of control strategies by means of a real building automation controller under defined and reproducible conditions without adverse effects on the users of a building. The controller is connected to a personal computer which models the building and systems engineering taking into account the user behaviour in real time. All gates of the building automation are tapped and provided as input data to the simulation. Based on this information, in the simulation the reaction of the building is calculated for each time step. The current spatial conditions are reported back to the building automation. Thus, the controller can be tested with all the functionality in the HIL environment. Any locations and environmental conditions in the development process can be compared and evaluated by means of the simulation. The goal is to develop an

  12. Prevalence and risk factors for Sick Building Syndrome among Italian correctional officers: A pilot study

    Directory of Open Access Journals (Sweden)

    Francesco Chirico

    2017-03-01

    Full Text Available Introduction: Over the past two decades, numerous studies on indoor air and the Sick Building Syndrome (SBS have been conducted, mostly in office environments. However, there is little knowledge about SBS in police officers. This study was aimed to fill this gap. Methods: A cross-sectional questionnaire survey was conducted in 2016 at the Triveneto Penitentiary Center, Northern Italy. Chi-square was used to test the difference of prevalence between office workers (OWs and correctional officers (COs of personal characteristics, cases of SBS, and general and mucocutaneous symptoms associated with SBS. A binary logistic regression was used to identify among individual, environmental, and psychosocial characteristics, factors associated with correctional officers’ Sick Building Syndrome. Results: Chi-squared analyses revealed that there were statistically significant differences in the estimated prevalence of SBS general symptoms (χ2 (1 = 12.22, P < .05, SBS mucocutaneous symptoms (χ2 (1 = 9.04, P < .05, and cases of SBS (χ2 (1 = 4.39, P <.05 between COs and OWs. COs reported that their health had been affected by the passive smoking (β = 2.34, P < .05 and unpleasant odour (β = 2.51, P < .05 as environmental risk factors; work-family conflict (β = 2.14, P < .05, psychological and physical isolation (β = 2.07, P < .05, and negative public image (β = 2.06, P < .05 as psychosocial risk factors. Finally, atopy (β = 2.02, P < .05 and to be current smoker (β = 2.02, P < .05 were statistically significant behavioral predictors of SBS among correctional officers. Discussion: Our survey showed that symptoms compatible with the sick building syndrome are common in correctional officers and that psychosocial work climate and exposure to passive smoking could have a strong influence on the prevalence of both general and mucocutaneous symptoms associated with SBS. A health policy for passive tobacco smoking within prisons, and for work-related stress

  13. Two-Pipe Chilled Beam System for Both Cooling and Heating of Office Buildings

    DEFF Research Database (Denmark)

    Afshari, Alireza; Gordnorouzi, Rouzbeh; Hultmark, Göran

    2013-01-01

    Simulations were performed to compare a conventional 4-pipe chilled beam system and a 2-pipe chilled beam system. The objective was to establish requirements, possibilities and limitations for a well-functioning 2-pipe chilled beam system for both cooling and heating of office buildings. The buil...

  14. Optimizing plug-in electric vehicle charging in interaction with a small office building

    Energy Technology Data Exchange (ETDEWEB)

    Momber, Ilan; Gomez, Tomas [Instituto de Investigacion Tecnologica (IIT), Madrid (Spain); Dallinger, David; Beer, Sebastian; Wietschel, Martin [Fraunhofer Institute for Systems and Innovation Research, Karlsruhe (Germany). Competence Center Energy Policy and Energy Systems; Marnay, Chris; Stadler, Michael [Lawrence Berkeley Lab., CA (United States)

    2011-07-01

    This paper considers the integration of plug-in electric vehicles (PEVs) in micro-grids. Extending a theoretical framework for mobile storage connection, the economic analysis here turns to the interactions of commuters and their driving behavior with office buildings. An illustrative example for a real office building is reported. The chosen system includes solar thermal, photovoltaic, combined heat and power generation as well as an array of plug-in electric vehicles with a combined aggregated capacity of 864 kWh. With the benefit-sharing mechanism proposed here and idealized circumstances, estimated cost savings of 5% are possible. Different pricing schemes were applied which include flat rates, demand charges, as well as hourly variable final customer tariffs and their effects on the operation of intermittent storage were revealed and examined in detail. Because the plug-in electric vehicle connection coincides with peak heat and electricity loads as well as solar radiation, it is possible to shift energy demand as desired in order to realize cost savings. (orig.)

  15. Office of Codes and Standards resource book. Section 1, Building energy codes and standards

    Energy Technology Data Exchange (ETDEWEB)

    Hattrup, M.P.

    1995-01-01

    The US Department of Energy`s (DOE`s) Office of Codes and Standards has developed this Resource Book to provide: A discussion of DOE involvement in building codes and standards; a current and accurate set of descriptions of residential, commercial, and Federal building codes and standards; information on State contacts, State code status, State building construction unit volume, and State needs; and a list of stakeholders in the building energy codes and standards arena. The Resource Book is considered an evolving document and will be updated occasionally. Users are requested to submit additional data (e.g., more current, widely accepted, and/or documented data) and suggested changes to the address listed below. Please provide sources for all data provided.

  16. Perceived Indoor Environment and Occupants’ Comfort in European “Modern” Office Buildings: The OFFICAIR Study

    Directory of Open Access Journals (Sweden)

    Ioannis A. Sakellaris

    2016-04-01

    Full Text Available Indoor environmental conditions (thermal, noise, light, and indoor air quality may affect workers’ comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants’ comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 “modern” office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain. Occupants assessed indoor environmental quality (IEQ using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality, and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants’ comfort. The highest association with occupants’ overall comfort was found for “noise”, followed by “air quality”, “light” and “thermal” satisfaction. Analysis of detailed parameters revealed that “noise inside the buildings” was highly associated with occupants’ overall comfort. “Layout of the offices” was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index, and building characteristics (office type and building’s location. Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants.

  17. Perceived Indoor Environment and Occupants’ Comfort in European “Modern” Office Buildings: The OFFICAIR Study

    Science.gov (United States)

    Sakellaris, Ioannis A.; Saraga, Dikaia E.; Mandin, Corinne; Roda, Célina; Fossati, Serena; de Kluizenaar, Yvonne; Carrer, Paolo; Dimitroulopoulou, Sani; Mihucz, Victor G.; Szigeti, Tamás; Hänninen, Otto; de Oliveira Fernandes, Eduardo; Bartzis, John G.; Bluyssen, Philomena M.

    2016-01-01

    Indoor environmental conditions (thermal, noise, light, and indoor air quality) may affect workers’ comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants’ comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 “modern” office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain). Occupants assessed indoor environmental quality (IEQ) using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality), and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor) of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants’ comfort. The highest association with occupants’ overall comfort was found for “noise”, followed by “air quality”, “light” and “thermal” satisfaction. Analysis of detailed parameters revealed that “noise inside the buildings” was highly associated with occupants’ overall comfort. “Layout of the offices” was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index), and building characteristics (office type and building’s location). Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants. PMID:27120608

  18. Test case preparation using a prototype

    OpenAIRE

    Treharne, Helen; Draper, J.; Schneider, Steve A.

    1998-01-01

    This paper reports on the preparation of test cases using a prototype within the context of a formal development. It describes an approach to building a prototype using an example. It discusses how a prototype contributes to the testing activity as part of a lifecycle based on the use of formal methods. The results of applying the approach to an embedded avionics case study are also presented.

  19. Double Skin Facades for Office Buildings. Literature Review

    Energy Technology Data Exchange (ETDEWEB)

    Poirazis, Harris

    2004-07-01

    The aim of this report is to describe the concept of Double Skin Facades based on different sources of literature. Although the concept is not new, there is a growing tendency from the architects to put it into practice. Its complexity and adaptability to different climatic conditions increase the need for careful design. Since the construction types can differ from one location to another, it is obvious that the comparison of different literature sources is not always relevant. Since the concept of Double Skin Facades is complicated and its use and function affects different parameters of the building, the literature studied is from different fields. It is clear that the design of the system is crucial for the performance of the building. It is the opinion of the author that the Double Skin Facades can provide both improved indoor climate and reduced use of energy in the same time if designed properly. If the approach is overall and the goals to be achieved are clear, then the mentioned system is flexible enough to meet climatic changes for most types of building use. The classification of the Double Skin Facades is important since the initial approach can influence the design stage. After selecting the type of Double Facade appropriate for the building, it is necessary to define the design and the technical parameters (such as the materials used) that can influence the function and the performance of the system and the physical properties of the cavity. The accuracy of calculations of the facade performance in the design stage will lead to more precise predictions. It is clear that by prioritizing the main goals of the double facade system in different ways, the building design and construction can differ adapting to the performance requirements of the designers, and the needs of the users. The advantages and disadvantages of double skin facades found in different literature sources are mentioned and described. Furthermore, examples of office buildings with

  20. Office building with an underground storage system. Operational experiences after one year; Buerogebaeude mit Erdspeicher. Betriebserfahrungen nach einem Jahr

    Energy Technology Data Exchange (ETDEWEB)

    Braun, Dorothee; Wehrli, Stefan [Basler und Hofmann AG, Zuerich (Switzerland)

    2011-07-01

    Self-sufficient heating and cooling - that was the principle of Basler paragraph Hofmann AG (Zuerich, Switzerland) and Stuecheli Architects (Zuerich, Switzerland) in the planning and constructing of a new office building in the Canton of Zuerich. For the first time an underground storage system was implemented in a commercial building. This underground storage refuels the solar energy in summer and supplies heating energy in winter. The office building was settled in in September, 2010. The pioneering project now delivers first empirical values with the underground storage system. These empirical values show: The concept comes up, but needs time.

  1. CONVERGING REDUNDANT SENSOR NETWORK INFORMATION FOR IMPROVED BUILDING CONTROL

    Energy Technology Data Exchange (ETDEWEB)

    Dale K. Tiller; Gregor P. Henze

    2004-11-01

    Knowing how many people occupy a building, and where they are located, is a key component of building energy management and security. Commercial, industrial and residential buildings often incorporate systems used to determine occupancy, however, current sensor technology and control algorithms limit the effectiveness of both energy management and security systems. This topical report describes results from the first phase of a project to design, implement, validate, and prototype new technologies to monitor occupancy, control indoor environment services, and promote security in buildings. Phase I of the project focused on instrumentation and data collection. In this project phase a new occupancy detection system was developed, commissioned and installed in a sample of private offices and open-plan office workstations. Data acquisition systems were developed and deployed to collect data on space occupancy profiles. Analysis tools based on Bayesian probability theory were applied to the occupancy data generated by the sensor network. The inference of primary importance is a probability distribution over the number of occupants and their locations in a building, given past and present sensor measurements. Inferences were computed for occupancy and its temporal persistence in individual offices as well as the persistence of sensor status. The raw sensor data were also used to calibrate the sensor belief network, including the occupancy transition matrix used in the Markov model, sensor sensitivity, and sensor failure models. This study shows that the belief network framework can be applied to the analysis of data streams from sensor networks, offering significant benefits to building operation compared to current practice.

  2. Acoustic classification of buildings in Europe – Main characteristics of national schemes for housing, schools, hospitals and office buildings

    DEFF Research Database (Denmark)

    Rasmussen, Birgit

    2018-01-01

    schemes define limit values for a number of acoustic performance areas, typically airborne and impact sound insulation, service equipment noise, traffic noise and reverberation time, i.e. the same as in regulations. Comparative studies of the national acoustic classification schemes in Europe show main......Building regulations specify minimum requirements, and more than ten countries in Europe have published national acoustic classification schemes with quality classes, the main purpose being to introduce easy specification of stricter acoustic criteria than defined in regulations. The very first...... classification schemes were published in the mid 1990’es and for dwellings only. Since then, more countries have introduced such schemes, some including also other building categories like e.g. schools, hospitals and office buildings, and the first countries have made updates more times. Acoustic classification...

  3. Guide for the recovery of high grade waste paper from federal office buildings through at-source separation

    Energy Technology Data Exchange (ETDEWEB)

    1978-01-01

    This guide is intended to serve as a manual for organizing and managing office waste paper recovery programs in Canadian federal buildings. Waste paper generated in such buildings is of particular interest for recycling as it is produced in sufficiently large amounts, and contains large amounts of high-grade waste paper which obtain good prices from paper mills. The key to successful recovery of such paper is separation, at the source of waste generation, from other less-valuable papers and non-paper materials. In recommending ways to do this, the manual covers assessment of the viability of a collection program in a particular building, estimating the quantities of waste generated, calculating storage space necessary, marketing the paper collected, using proper collection and storage containers, promoting employee awareness, and administering and monitoring the program. A sample cost-benefit analysis is given for a general office building with 1,000 employees. Includes glossary. 14 refs., 10 figs., 5 tabs.

  4. Final report of the decontamination and decommissioning of Building 44 at the Grand Junction Projects Office Facility

    International Nuclear Information System (INIS)

    Widdop, M.R.

    1996-07-01

    The U.S. Department of Energy (DOE) Junction Projects Office (GJPO) occupies a 61.7 acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission's domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the Grand Junction Projects Office Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, is also the remedial action contractor. Building 44 was radiologically contaminated and the building was demolished in 1994. The soil area within the footprint of the building was not contaminated; it complies with the identified standards and the area can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building

  5. Final report of the decontamination and decommissioning of Building 34 at the Grand Junction Projects Office Facility

    International Nuclear Information System (INIS)

    Widdop, M.R.

    1996-08-01

    The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7 acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission's domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the Grand Junction Projects Office Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, was also the remedial action contractor. Building 34 was radiologically contaminated and the building was demolished in 1996. The soil area within the footprint of the building was analyzed and found to be not contaminated. The area can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual closeout report for each contaminated GJPO building

  6. Assessment of energy and economic performance of office building models: a case study

    Science.gov (United States)

    Song, X. Y.; Ye, C. T.; Li, H. S.; Wang, X. L.; Ma, W. B.

    2016-08-01

    Energy consumption of building accounts for more than 37.3% of total energy consumption while the proportion of energy-saving buildings is just 5% in China. In this paper, in order to save potential energy, an office building in Southern China was selected as a test example for energy consumption characteristics. The base building model was developed by TRNSYS software and validated against the recorded data from the field work in six days out of August-September in 2013. Sensitivity analysis was conducted for energy performance of building envelope retrofitting; five envelope parameters were analyzed for assessing the thermal responses. Results indicated that the key sensitivity factors were obtained for the heat-transfer coefficient of exterior walls (U-wall), infiltration rate and shading coefficient (SC), of which the sum sensitivity factor was about 89.32%. In addition, the results were evaluated in terms of energy and economic analysis. The analysis of sensitivity validated against some important results of previous studies. On the other hand, the cost-effective method improved the efficiency of investment management in building energy.

  7. A Laboratory for studying radon mitigation methods in high-rise office buildings in Hong Kong

    International Nuclear Information System (INIS)

    Leung, J.K.C.; Hung, L.C.; Tso, M.Y.W.

    1996-01-01

    A territory-wide survey of indoor radon level in 1993 showed that 17% of offices Hong Kong have radon concentrations above 200 Bq m -3 compared with 4% for dwellings. Consequently, the Radioisotope Unit Radon Analysis Laboratory (RURAL) is being built for studying radon mitigation methods applicable to high-rise office buildings. The laboratory consists of three rooms; the main exposure room is built of concrete and is surrounded by the buffer room; and all controls and operations are done inside the control room. The exposure room can, with the aid of the buffer room, simulate any environmental conditions that can be faced by a real building. The pressure, temperature and humidity can be adjusted to any meteorological conditions that can be found in Hong Kong. Pressure differential and temperature differential can be adjusted to simulate the arrival of fronts, troughs or typhoons. Aerosol concentration and distribution inside the exposure room are controllable as well as the ventilation conditions. Various mitigation methods will be tested under different conditions. Passive methods include application of radon barriers to building structures and active methods include the use of air cleaners; techniques to increase radon daughters plateout or reduce their attachment to aerosols; and various modifications to the ventilation systems. Mitigation techniques involving modifications to the building strictures and building services will also be developed with the help of the RURAL. (author)

  8. Economic, Environmental and Health Implications of Enhanced Ventilation in Office Buildings.

    Science.gov (United States)

    MacNaughton, Piers; Pegues, James; Satish, Usha; Santanam, Suresh; Spengler, John; Allen, Joseph

    2015-11-18

    Current building ventilation standards are based on acceptable minimums. Three decades of research demonstrates the human health benefits of increased ventilation above these minimums. Recent research also shows the benefits on human decision-making performance in office workers, which translates to increased productivity. However, adoption of enhanced ventilation strategies is lagging. We sought to evaluate two of the perceived potential barriers to more widespread adoption-Economic and environmental costs. We estimated the energy consumption and associated per building occupant costs for office buildings in seven U.S. cities, representing different climate zones for three ventilation scenarios (standard practice (20 cfm/person), 30% enhanced ventilation, and 40 cfm/person) and four different heating, ventilation and air conditioning (HVAC) system strategies (Variable Air Volume (VAV) with reheat and a Fan Coil Unit (FCU), both with and without an energy recovery ventilator). We also estimated emissions of greenhouse gases associated with this increased energy usage, and, for comparison, converted this to the equivalent number of vehicles using greenhouse gas equivalencies. Lastly, we paired results from our previous research on cognitive function and ventilation with labor statistics to estimate the economic benefit of increased productivity associated with increasing ventilation rates. Doubling the ventilation rate from the American Society of Heating, Refrigeration and Air-Conditioning Engineers minimum cost less than $40 per person per year in all climate zones investigated. Using an energy recovery ventilation system significantly reduced energy costs, and in some scenarios led to a net savings. At the highest ventilation rate, adding an ERV essentially neutralized the environmental impact of enhanced ventilation (0.03 additional cars on the road per building across all cities). The same change in ventilation improved the performance of workers by 8

  9. Economic, Environmental and Health Implications of Enhanced Ventilation in Office Buildings

    Directory of Open Access Journals (Sweden)

    Piers MacNaughton

    2015-11-01

    Full Text Available Introduction: Current building ventilation standards are based on acceptable minimums. Three decades of research demonstrates the human health benefits of increased ventilation above these minimums. Recent research also shows the benefits on human decision-making performance in office workers, which translates to increased productivity. However, adoption of enhanced ventilation strategies is lagging. We sought to evaluate two of the perceived potential barriers to more widespread adoption—Economic and environmental costs. Methods: We estimated the energy consumption and associated per building occupant costs for office buildings in seven U.S. cities, representing different climate zones for three ventilation scenarios (standard practice (20 cfm/person, 30% enhanced ventilation, and 40 cfm/person and four different heating, ventilation and air conditioning (HVAC system strategies (Variable Air Volume (VAV with reheat and a Fan Coil Unit (FCU, both with and without an energy recovery ventilator. We also estimated emissions of greenhouse gases associated with this increased energy usage, and, for comparison, converted this to the equivalent number of vehicles using greenhouse gas equivalencies. Lastly, we paired results from our previous research on cognitive function and ventilation with labor statistics to estimate the economic benefit of increased productivity associated with increasing ventilation rates. Results: Doubling the ventilation rate from the American Society of Heating, Refrigeration and Air-Conditioning Engineers minimum cost less than $40 per person per year in all climate zones investigated. Using an energy recovery ventilation system significantly reduced energy costs, and in some scenarios led to a net savings. At the highest ventilation rate, adding an ERV essentially neutralized the environmental impact of enhanced ventilation (0.03 additional cars on the road per building across all cities. The same change in ventilation

  10. Built sustainability. The office building of the Federal Ministry for the Environment in Berlin; Gebaute Nachhaltigkeit. Der Berliner Dienstsitz des Bundesumweltministeriums

    Energy Technology Data Exchange (ETDEWEB)

    Mager, Hans; Schulz, Juergen; Weigand, Reinhold (comps.)

    2011-06-15

    With the move into the office building in the Stresemann Street in Berlin (Federal Republic of Germany), the Federal Ministry for the Environment, Nature Conservation and Nuclear Safety adopts a remarkable new building in the new centre of Berlin. It is the first Federal authority at all which works in a low-energy and passive house. This brochure under consideration reports on the history and architecture of the new office building as well as its sustainable energy management and life cycle assessments.

  11. Simulation of energy use, human thermal comfort and office work performance in buildings with moderately drifting operative temperatures

    DEFF Research Database (Denmark)

    Kolarik, Jakub; Toftum, Jørn; Olesen, Bjarne W.

    2011-01-01

    Annual primary energy use in a central module of an office building consisting of two offices separated with a corridor was estimated by means of dynamic computer simulations. The simulations were conducted for conventional all-air VAV ventilation system and thermo active building system (TABS) s....... The TABS working in a moderate climate kept the predicted percentage of dissatisfied (PPD) 10%; 1.4% in comparison to 17.5% h/yr. The highest estimated loss of occupants’ productivity related to their thermal sensation hasn’t exceeded 1% in whole year average....

  12. Solar and Lighting Transmission through Complex Fenestration Systems of Office Buildings in a Warm and Dry Climate of Chile

    Directory of Open Access Journals (Sweden)

    Waldo Bustamante

    2014-05-01

    Full Text Available Overheating, glare, and high-energy demand are recurrent problems in office buildings in Santiago, Chile (33°27'S; 70°42'W during cooling periods. Santiago climate is warm and dry, with high solar radiation and temperature during most of the year. The objective of this paper is to evaluate the thermal and daylighting performance of office buildings transparent façades composed of three different complex fenestration systems (CFS. Each CFS contains a different external shading device (ESD: (1 external roller, (2 vertical undulated and perforated screens, and (3 tilted undulated and perforated screens. The study was carried out by in situ monitoring in three office buildings in Santiago, Chile. Buildings were selected from a database of 103 buildings, representing those constructed between 2005 and 2011 in the city. The monitoring consisted of measuring the short wave solar and daylighting transmission through fenestration systemsby means of pyranometers and luxometers, respectively. This paper shows measurements that were carried out during summer period. A good performance is observed in a building with the external roller system. This system—applied to a northwest façade—shows a regular and high solar and daylighting control of incoming solar radiation. The other two ESD systems evidence a general good performance. However, some deficiencies at certain times of the day were detected, suggesting a non-appropriated design.

  13. Office layout affecting privacy, interaction, and acoustic quality in LEED-certified buildings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young S. [School of Planning, Design, and Construction, Michigan State University, East Lansing, MI 48823 (United States)

    2010-07-15

    The study investigated differences in worker satisfaction and perceived job performance regarding privacy, interaction, and acoustic quality issues in personal workspaces between five office types in LEED-certified buildings. It finds that people in high cubicles showed significantly lower satisfaction and job performance in relation to visual privacy and interaction with co-workers than both enclosed private and enclosed shared office types. They also showed significantly lower satisfaction with noise level and sound privacy and lower job performance perceived by acoustic quality than enclosed private, enclosed shared, and bullpen types. The bullpen type, open-plan office without partitions, presented significantly higher satisfaction with noise level and higher performance perceived by acoustic quality than both high and low cubicles. Considering the bullpen type also showed higher satisfaction with sound privacy than the high cubicle type, high partitions don't seem to contribute to creating workspaces where people can have a secure conversation. The bullpen type didn't show any difference from the enclosed shared type in all privacy, interaction, and acoustic quality questions, indicating it may be a good option for a small office space instead of the enclosed shared type. (author)

  14. Low Carbon Design Research on the Space Layout Types of Office Buildings

    Science.gov (United States)

    Xia, Bing

    2018-01-01

    It is beneficial to find out the relationship of the spatial layout and low-carbon design in order to reduce buildings’ carbon emissions in the conceptual design phase. This paper analyzes and compares shape coefficient values, annual energy consumption and lighting performance of office buildings of different space layout types in Shanghai. Based on morphological characteristics of different types, the study also analyzes and presents low-carbon design strategies for each single type. This study assumes that architects should conduct passive and active design according to the specific building space layout, so that to make best use of the advantages and bypassing the disadvantages, in order to maximally reduce buildings’ carbon emissions.

  15. Thermal performance of air-conditioned office buildings constructed with inclined walls in different climates in China

    International Nuclear Information System (INIS)

    Chan, A.L.S.; Chow, T.T.

    2014-01-01

    Highlights: • A generic fully air-conditioned office building with inclined walls was modeled. • Simulations were run under climatic conditions in three modern cities in China. • Reduction in cooling load can outweigh the increase in heating load for Hong Kong. • Inclined angle of 30° is appropriate for inverted pyramidal building in Hong Kong. • Building constructed with inclined walls is not encouraged in Shanghai and Beijing. - Abstract: An inverted pyramidal building is built with inclined walls instead of the traditional vertical façades. In terms of thermal performance, an inverted pyramidal building can provide a self-shading effect against the beam solar radiation, leading to a reduction in solar heat gain as well as building cooling load. On the other hand, the heating requirement of an inverted pyramidal building will be increased in winter. There is a strong dependency of building performance on the climatic condition. In this study, a generic air-conditioned office building with inclined walls set at different inclination angles was modeled using a building energy simulation program. Computer simulations were run to assess the thermal performance of the building constructed with inclined walls under different climatic conditions in three modern cities in China–Hong Kong, Shanghai and Beijing. The results reveal that for the building cases with inclined walls set at different inclination angles in subtropical Hong Kong, the saving in annual cooling load ranges from 0.6% to 10.9% and can outweigh the increase in heating load. Moreover, an inclination angle of 30° was found as a better design option for an inverted pyramidal building with symmetrical layout design under the climatic condition in Hong Kong. For the other two cities: Shanghai and Beijing, the saving in cooling load due to self-shading effect cannot offset the increased heating requirement. Design and construction of an inverted pyramidal building is not encouraged in these two

  16. Indoor Environmental Risk Factors for Occupant Symptoms in 100U.S. Office Buildings: Summary of Three Analyses from the EPA BASEStudy

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, M.J.; Lei-Gomez, Q.; Cozen, M.; Brightman, H.S.; Apte,M.; Erdmann, C.A.; Brunner, G.; Girman, J.R.

    2006-02-01

    This paper summarizes three analyses of data on building-related environmental factors and occupant symptoms collected from 100 representative large U.S. office buildings. Using multivariate logistic regression models, we found increased occupant symptoms associated with a number of building-related factors, including lower ventilation rates even at the current guideline levels, lack of scheduled cleaning for air-conditioning drain pans and cooling coils, poor condition of cooling coils, poorly maintained humidification systems, and lower outdoor air intake height. Some expected relationships were not found, and several findings were opposite of expected. Although requiring replication, these findings suggest preventive actions to reduce occupant symptoms in office buildings.

  17. Prototypical Consolidation Demonstration Project: Final report

    International Nuclear Information System (INIS)

    Gili, J.A.; Poston, V.K.

    1993-11-01

    This is the final report of the Prototypical Consolidation Demonstration Project, which was funded by the US Department of Energy's Office of Civilian Radioactive Waste Management. The project had two objectives: (a) to develop and demonstrate a prototype of production-scale equipment for the dry, horizontal consolidation and packaging of spent nuclear fuel rods from commercial boiling water reactor and pressurized water reactor fuel assemblies, and (b) to report the development and demonstration results to the US Department of Energy, Idaho Operations Office. This report summarizes the activities and conclusions of the project management contractor, EG ampersand G Idaho, Inc., and the fabrication and testing contractor, NUS Corporation (NUS). The report also presents EG ampersand G Idaho's assessments of the equipment and procedures developed by NUS

  18. Louisiana State Lands and Buildings, Geographic NAD83, LA State Land Office (2007) [slabs_slo_2007

    Data.gov (United States)

    Louisiana Geographic Information Center — This dataset represents land and/or building areas for the state of Louisiana. This dataset was compiled by the State Land Office from Historical Records (SLABS)...

  19. Economic feasibility of maximising daylighting of a standard office building with efficient electric lighting

    DEFF Research Database (Denmark)

    Fontoynont, Marc; Ramananarivo, Karine; Soreze, Thierry Silvio Claude

    2016-01-01

    This paper investigates the cost of developing various daylighting strategies for a standard office building in relation to their ability to reduce electric lighting consumption. The reference building design for this study corresponds to a typical configuration that minimises the construction...... costs and is typical of the French market. We have compared scenarios that entail moving service spaces to the periphery, increasing ceiling height and adding light wells of various shapes. These special features increased the proportion of the indoor area with sufficient daylight by up to 40...

  20. Empirical Essays on Office Market Dynamics

    NARCIS (Netherlands)

    M.G.J. Jennen (Maarten)

    2008-01-01

    textabstractOffice buildings are a major investment vehicle, provide a working environment for numerous employees across the globe and determine the skyline of major cities. Put differently: office buildings matter. This dissertation consists of six studies and focuses on office buildings from a

  1. All around ecological. Administrative building of the district office Goeppingen; Rundum oekologisch. Verwaltungsgebaeude des Landratsamts Goeppingen

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2011-07-15

    This district office in Goeppingen (Federal Republic of Germany) just had ten months in order to build a completely new administrative building. For the employees of the district's waste company, a house was needed with a gross floor area of 2,020 m{sup 2}. Despite the tight time frame, one correlated to an environmentally friendly and energy-saving concept: The building should consume energy as little as possible in future. The new building was constructed extremely rapidly and is now regarded as a flagship project: it is heated using a geothermal heat pump and seven geothermal probes. A sophisticated system provides for storage and recycling of excess energy.

  2. Energy-Efficient Office Buildings at High Latitudes

    Energy Technology Data Exchange (ETDEWEB)

    Lerum, V.

    1996-12-31

    This doctoral thesis describes a method for energy efficient office building design at high latitudes and cold climates. The method combines daylighting, passive solar heating, solar protection, and ventilative cooling. The thesis focuses on optimal design of an equatorial-facing fenestration system. A spreadsheet framework linking existing simplified methods is used. The daylight analysis uses location specific data on frequency distribution of diffuse daylight on vertical surfaces to estimate energy savings from optimal window and room configurations in combination with a daylight-responsive electric lighting system. The passive solar heating analysis is a generalization of a solar load ratio method adapted to cold climates by combining it with the Norwegian standard NS3031 for winter months when the solar savings fraction is negative. The emphasis is on very high computational efficiency to permit rapid and comprehensive examination of a large number of options early in design. The procedure is illustrated for a location in Trondheim, Norway, testing the relative significance of various design improvement options relative to a base case. The method is also tested for two other locations in Norway, at latitudes 58 and 70 degrees North. The band of latitudes between these limits covers cities in Alaska, Canada, Greenland, Iceland, Scandinavia, Finland, Russia, and Northern Japan. A comprehensive study of the ``whole building approach`` shows the impact of integrated daylighting and low-energy design strategies. In general, consumption of lighting electricity may be reduced by 50-80%, even at extremely high latitudes. The reduced internal heat from electric lights is replaced by passive solar heating. 113 refs., 85 figs., 25 tabs.

  3. Using rapid prototyping to design a smoking cessation website with end-users

    OpenAIRE

    Ronquillo, C. E.; Currie, L.; Rowsell, D.; Phillips, J. C.

    2016-01-01

    Rapid prototyping is an iterative approach to design involving cycles of prototype building, review by end-users, and refinement, and can be a valuable tool in user-centered website design. Informed by various user-centered approaches, we used rapid prototyping as a tool to collaborate with users in building a peer-support focused smoking-cessation website for gay men living with HIV. Rapid prototyping was effective in eliciting feedback on the needs of this group of potential end-users\\ud fr...

  4. DataCollection Prototyping

    CERN Multimedia

    Beck, H.P.

    DataCollection is a subsystem of the Trigger, DAQ & DCS project responsible for the movement of event data from the ROS to the High Level Triggers. This includes data from Regions of Interest (RoIs) for Level 2, building complete events for the Event Filter and finally transferring accepted events to Mass Storage. It also handles passing the LVL1 RoI pointers and the allocation of Level 2 processors and load balancing of Event Building. During the last 18 months DataCollection has developed a common architecture for the hardware and software required. This involved a radical redesign integrating ideas from separate parts of earlier TDAQ work. An important milestone for this work, now achieved, has been to demonstrate this subsystem in the so-called Phase 2A Integrated Prototype. This prototype comprises the various TDAQ hardware and software components (ROSs, LVL2, etc.) under the control of the TDAQ Online software. The basic functionality has been demonstrated on small testbeds (~8-10 processing nodes)...

  5. PERTS: A Prototyping Environment for Real-Time Systems

    Science.gov (United States)

    Liu, Jane W. S.; Lin, Kwei-Jay; Liu, C. L.

    1993-01-01

    PERTS is a prototyping environment for real-time systems. It is being built incrementally and will contain basic building blocks of operating systems for time-critical applications, tools, and performance models for the analysis, evaluation and measurement of real-time systems and a simulation/emulation environment. It is designed to support the use and evaluation of new design approaches, experimentations with alternative system building blocks, and the analysis and performance profiling of prototype real-time systems.

  6. Using Rapid Prototyping to Design a Smoking Cessation Website with End-Users.

    Science.gov (United States)

    Ronquillo, Charlene; Currie, Leanne; Rowsell, Derek; Phillips, J Craig

    2016-01-01

    Rapid prototyping is an iterative approach to design involving cycles of prototype building, review by end-users and refinement, and can be a valuable tool in user-centered website design. Informed by various user-centered approaches, we used rapid prototyping as a tool to collaborate with users in building a peer-support focused smoking-cessation website for gay men living with HIV. Rapid prototyping was effective in eliciting feedback on the needs of this group of potential end-users from a smoking cessation website.

  7. Requirements of air conditioners for office buildings. Pt. 2

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, W

    1988-02-01

    Presenting numerous explanatory diagrams part two of the report deals with auxiliary ventilation systems (mechanical systems); the influence of different ventilation circuits on the air quality (particle concentration, floor and ceiling air outlets); the requirements of heating systems (dimensioning of heating systems, effects of ventilation systems on the heat demand, reduced heat demand owing to auxiliary ventilation systems); the requirements of cooling (cooling loads in office buildings, room temperatures in the case of natural cooling, auxiliary ventilation systems, and cooling by means of refrigerators, floor/ceiling cooling systems); permissible ambient air velocities (complaints about draughts). Bottom-to-top ventilation circuits were found to provide for better air qualities and lower ambient air velocities without increasing the systems' energy demand. (HWJ).

  8. Contaminants in Buildings and Occupied Spaces as Risk Factors forOccupant Symptoms in U.S. Office Buildings: Findings from the U.S. EPABASE Study

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, M.J.; Mirer, A.; Lei-Gomez, Q.

    2007-08-01

    Nonspecific building-related symptoms among occupants of modern office buildings worldwide are common and may be associated with important reductions in work performance, but their etiology remains uncertain. Most reported research into environmental risk factors for these symptoms has focused on ventilation system-related factors, dampness, and particle removal through filtration and cleaning, with relatively few studies of other potential sources of indoor contaminants. We analyzed data collected by the U.S. Environmental Protection Agency (EPA) from a representative sample of 100 large U.S. office buildings--the Building Assessment and Survey Evaluation (BASE) study--using multivariate-adjusted logistic regression models with generalized estimating equations. We estimated odds ratios (ORs) and 95% confidence intervals (CIs) for associations between seven building-related symptom outcomes and a diverse set of potential indoor and outdoor sources for indoor pollutants. Although most of the investigated risk factors showed no apparent association with building-related symptoms, some interesting associations resulted. Increased prevalence of symptoms was associated with carpets older than one year (lower respiratory symptoms), non-carpeted floors (upper and lower respiratory symptoms), older furniture (eye and skin symptoms), infrequent vacuuming (upper respiratory, eye, and skin symptoms and headache), and masonry exterior walls (cough, eye symptoms, and fatigue/concentration difficulty). For the many potential risk factors assessed, almost none had been investigated previously, and many associations found here may have been by chance. Additional confirmatory research focused on risk factors initially identified here is needed, using more objective measures of health outcomes and risk factors or exposures.

  9. Methodology of CO{sub 2} emission evaluation in the life cycle of office building facades

    Energy Technology Data Exchange (ETDEWEB)

    Taborianski, Vanessa Montoro; Prado, Racine T.A., E-mail: racine.prado@poli.usp.br

    2012-02-15

    The construction industry is one of the greatest sources of pollution because of the high level of energy consumption during its life cycle. In addition to using energy while constructing a building, several systems also use power while the building is operating, especially the air-conditioning system. Energy consumption for this system is related, among other issues, to external air temperature and the required internal temperature of the building. The facades are elements which present the highest level of ambient heat transfer from the outside to the inside of tall buildings. Thus, the type of facade has an influence on energy consumption during the building life cycle and, consequently, contributes to buildings' CO{sub 2} emissions, because these emissions are directly connected to energy consumption. Therefore, the aim is to help develop a methodology for evaluating CO{sub 2} emissions generated during the life cycle of office building facades. The results, based on the parameters used in this study, show that facades using structural glazing and uncolored glass emit the most CO{sub 2} throughout their life cycle, followed by brick facades covered with compound aluminum panels or ACM (Aluminum Composite Material), facades using structural glazing and reflective glass and brick facades with plaster coating. On the other hand, the typology of facade that emits less CO{sub 2} is brickwork and mortar because its thermal barrier is better than structural glazing facade and materials used to produce this facade are better than brickwork and ACM. Finally, an uncertainty analysis was conducted to verify the accuracy of the results attained. - Highlights: Black-Right-Pointing-Pointer We develop a methodology for evaluating CO{sub 2} emissions generated during the life cycle of office building facades. Black-Right-Pointing-Pointer This methodology is based in LCA. Black-Right-Pointing-Pointer We use an uncertainty analysis to verify the accuracy of the results

  10. Economic analysis of the daylight-linked lighting control system in office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Yang, In-Ho; Nam, Eun-Ji [Department of Architectural Engineering, College of Engineering, Dongguk University, 26-3, Pil-dong, Chung-gu, Seoul 100-715 (Korea)

    2010-08-15

    The objective of this study is to perform an economic analysis of the daylight-linked automatic on/off lighting control system installed for the purpose of energy savings in office buildings. For this, a building was chosen as a typical example, and the energy cost was calculated by using the daylight and building energy analysis simulation. When the lighting control was utilized, an economic analysis was performed using a payback period that was calculated by comparing the initial cost of installing the lighting control system with the annual energy cost which was reduced thanks to the application of the lighting control. The results showed that the lighting energy consumption, when the lighting control was applied, was reduced by an average of 30.5% compared with the case that there was not lighting control applied. Also, the result for total energy consumption showed that, when lighting control was applied, this was reduced by 8.5% when the glazing ratio was 100%, 8.2% for 80%, and 7.6% for 60% when compared to non-application. The payback period was analyzed in terms of the number of floors in a building; 10 floors, 20 floors, 30 floors, and 40 floors. Hence, the building with 40 floors and glazing ratio 100% resulted in the shortest payback period of 8.8 years, the building with 10 floors and glazing ratio 60% resulted in the longest period of 12.7 years. In other words, the larger the glazing ratio and the number of building floors are, the shorter the payback period is. (author)

  11. Assessment of Energy Impact of Window Technologies for Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Tianzhen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division; Selkowitz, Stephen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division; Yazdanian, Mehry [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division

    2009-10-01

    Windows play a significant role in commercial buildings targeting the goal of net zero energy. This report summarizes research methodology and findings in evaluating the energy impact of windows technologies for commercial buildings. The large office prototypical building, chosen from the DOE commercial building benchmarks, was used as the baseline model which met the prescriptive requirements of ASHRAE Standard 90.1-2004. The building simulations were performed with EnergyPlus and TMY3 weather data for five typical US climates to calculate the energy savings potentials of six windows technologies when compared with the ASHRAE 90.1-2004 baseline windows. The six windows cover existing, new, and emerging technologies, including ASHRAE 189.1 baseline windows, triple pane low-e windows, clear and tinted double pane highly insulating low-e windows, electrochromic (EC) windows, and highly insulating EC windows representing the hypothetically feasible optimum windows. The existing stocks based on average commercial windows sales are included in the analysis for benchmarking purposes.

  12. Technical Support Document: 50% Energy Savings for Small Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, Brian A.; Wang, Weimin; Huang, Yunzhi; Lane, Michael D.; Liu, Bing

    2010-04-30

    The Technical Support Document (TSD) for 50% energy savings in small office buildings documents the analysis and results for a recommended package of energy efficiency measures (EEMs) referred to as the advanced EEMs. These are changes to a building design that will reduce energy usage. The package of advanced EEMs achieves a minimum of 50% energy savings and a construction area weighted average energy savings of 56.6% over the ANSI/ASHRAE/IESNA Standard 90.1-2004 for 16 cities which represent the full range of climate zones in the United States. The 50% goal is for site energy usage reduction. The weighted average is based on data on the building area of construction in the various climate locations. Cost-effectiveness of the EEMs is determined showing an average simple payback of 6.7 years for all 16 climate locations. An alternative set of results is provided which includes a variable air volume HVAC system that achieves at least 50% energy savings in 7 of the 16 climate zones with a construction area weighted average savings of 48.5%. Other packages of EEMs may also achieve 50% energy savings; this report does not consider all alternatives but rather presents at least one way to reach the goal. Design teams using this TSD should follow an integrated design approach and utilize additional analysis to evaluate the specific conditions of a project.

  13. Multiple regression models for energy use in air-conditioned office buildings in different climates

    International Nuclear Information System (INIS)

    Lam, Joseph C.; Wan, Kevin K.W.; Liu Dalong; Tsang, C.L.

    2010-01-01

    An attempt was made to develop multiple regression models for office buildings in the five major climates in China - severe cold, cold, hot summer and cold winter, mild, and hot summer and warm winter. A total of 12 key building design variables were identified through parametric and sensitivity analysis, and considered as inputs in the regression models. The coefficient of determination R 2 varies from 0.89 in Harbin to 0.97 in Kunming, indicating that 89-97% of the variations in annual building energy use can be explained by the changes in the 12 parameters. A pseudo-random number generator based on three simple multiplicative congruential generators was employed to generate random designs for evaluation of the regression models. The difference between regression-predicted and DOE-simulated annual building energy use are largely within 10%. It is envisaged that the regression models developed can be used to estimate the likely energy savings/penalty during the initial design stage when different building schemes and design concepts are being considered.

  14. Evaluating economic and environmental aspects of using solar panels on multi-angled facades of office buildings

    Science.gov (United States)

    Hannoudi, Loay Akram; Lauring, Michael; Christensen, Jørgen Erik

    2017-09-01

    This paper is concerned with using solar panels as high-tech cladding materials on multi-angled facades for office buildings. The energy produced by the solar panels will be consumed inside the office rooms by cooling compressors, ventilation, lighting and office equipment. Each multi-angled facade unit is directed into two different orientations on a vertical axis (right and left), but not tilted up and down. The different facade orientations will optimize the use of solar radiation to produce the needed energy from the solar panels when placing them on the parapets of these facades. In this regard, four scenarios with different facade configurations and orientations are evaluated and discussed. The method for the simulations and calculations depends on two main programs: first, IDA ICE program to calculate the energy consumption and evaluate the indoor climate of the building; and second, PVBAT to calculate the cost of the electricity produced by the solar panels and evaluate the total amount of energy produced from these panels along with the ratio to the energy bought directly from the electricity grid. There is also an environmental evaluation for the system by calculating the CO2 emissions in the different scenarios.

  15. Assessment of microbiological indoor air quality in an Italian office building equipped with an HVAC system.

    Science.gov (United States)

    Bonetta, Sa; Bonetta, Si; Mosso, S; Sampò, S; Carraro, E

    2010-02-01

    The purpose of this study was to evaluate the level and composition of bacteria and fungi in the indoor air of an Italian office building equipped with a heating, ventilation and air conditioning (HVAC) system. Airborne bacteria and fungi were collected in three open-space offices during different seasons. The microbial levels in the outdoor air, supply air diffusers, fan coil air flow and air treatment unit humidification water tank were used to evaluate the influence of the HVAC system on indoor air quality (IAQ). A medium-low level of bacterial contamination (50-500 CFU/m(3)) was found in indoor air. Staphylococcus and Micrococcus were the most commonly found genera, probably due to human presence. A high fungal concentration was measured due to a flood that occurred during the winter. The indoor seasonal distribution of fungal genera was related to the fungal outdoor distribution. Significant seasonal and daily variation in airborne microorganisms was found, underlining a relationship with the frequency of HVAC system switching on/off. The results of this monitoring highlight the role of the HVAC system on IAQ and could be useful to better characterise bacterial and fungal population in the indoor air of office buildings.

  16. Solar heating and cooling system for an office building at Reedy Creek Utilities

    Science.gov (United States)

    1978-01-01

    The solar energy system installed in a two story office building at a utilities company, which provides utility service to Walt Disney World, is described. The solar energy system application is 100 percent heating, 80 percent cooling, and 100 percent hot water. The storage medium is water with a capacity of 10,000 gallons hot and 10,000 gallons chilled water. Performance to date has equaled or exceeded design criteria.

  17. Light Guide Collector Prototype: Laboratory Testing

    OpenAIRE

    Jitka - Mohelnikova; Stanislav Darula; Ayodeji Omishore; Petr Mohelnik; Denis Micek

    2017-01-01

    The article reviews the potential of light guide system equipped by a concentrator device capturing daylight applicable for illumination of building interiors and presents results of experiments on performance of its prototype. The main goal is focused on the comparison of traditional solutions and newly developed prototype of the light guide system and presents examination of its light transmission efficiency based on the laboratory experiments.

  18. European indoor air quality survey in 56 office buildings; Europees binnenluchtkwaliteitsonderzoek in 56 kantoorgebouwen

    Energy Technology Data Exchange (ETDEWEB)

    Bluyssen, P.M. [Afdeling Binnenmilieu, Bouwfysica en Installaties, TNO Bouw, Delft (Netherlands)

    1996-12-01

    The title survey started at the end of 1992. Trained sensory panels were used to investigate office buildings all over Europe. Measurements were performed at five selected locations in each building. The buildings were studied while normally occupied and ventilated to identify the pollution sources in the spaces and to quantify the total pollution load caused by the occupants and their activities and the ventilation systems. The investigation included physical and chemical measurements, assessment of the perceived air quality in the spaces by a trained sensory panel, and measurement of the outdoor air supply to the spaces. A questionnaire for evaluating retrospective and immediate symptoms and perceptions was given to the occupants of the buildings. The building characteristics were described by use of a check-list. The annual energy consumption of the buildings and the weather conditions were registered. Results and conclusions of the audit in 56 buildings in Europe are presented. The analysis and discussion of the results are a summary of the work done and show that ventilation is not the solution for the removal of pollutants, but that source control is the first method to be applied. Furthermore, the analysis and discussions are focused mainly on the comparison between sensory assessments and the other measurements performed. 13 figs., 7 tabs., 25 refs.

  19. Mechatronic Prototype of Parabolic Solar Tracker.

    Science.gov (United States)

    Morón, Carlos; Díaz, Jorge Pablo; Ferrández, Daniel; Ramos, Mari Paz

    2016-06-15

    In the last 30 years numerous attempts have been made to improve the efficiency of the parabolic collectors in the electric power production, although most of the studies have focused on the industrial production of thermoelectric power. This research focuses on the application of this concentrating solar thermal power in the unexplored field of building construction. To that end, a mechatronic prototype of a hybrid paraboloidal and cylindrical-parabolic tracker based on the Arduido technology has been designed. The prototype is able to measure meteorological data autonomously in order to quantify the energy potential of any location. In this way, it is possible to reliably model real commercial equipment behavior before its deployment in buildings and single family houses.

  20. Construction and operation of a support facilities (Building 729) for operation/testing of a prototype accelerator/storage ring (XLS) and machine shop for the National Synchrotron Light Source at Brookhaven National Laboratory, Upton, New York

    International Nuclear Information System (INIS)

    1992-06-01

    Proposed action is to construct at BNL a 5,600-ft 2 support building, install and operate a prototypic 200 MeV accelerator and a prototypic 700 MeV storage ring within, and to construct and operate a 15 kV substation to power the building. The accelerator and storage ring would comprise the x-ray lithography source or XLS

  1. Review on CNC-Rapid Prototyping

    International Nuclear Information System (INIS)

    M Nafis O Z; Nafrizuan M Y; Munira M A; Kartina J

    2012-01-01

    This article reviewed developments of Computerized Numerical Control (CNC) technology in rapid prototyping process. Rapid prototyping (RP) can be classified into three major groups; subtractive, additive and virtual. CNC rapid prototyping is grouped under the subtractive category which involves material removal from the workpiece that is larger than the final part. Richard Wysk established the use of CNC machines for rapid prototyping using sets of 2½-D tool paths from various orientations about a rotary axis to machine parts without refixturing. Since then, there are few developments on this process mainly aimed to optimized the operation and increase the process capabilities to stand equal with common additive type of RP. These developments include the integration between machining and deposition process (hybrid RP), adoption of RP to the conventional machine and optimization of the CNC rapid prototyping process based on controlled parameters. The article ended by concluding that the CNC rapid prototyping research area has a vast space for improvement as in the conventional machining processes. Further developments and findings will enhance the usage of this method and minimize the limitation of current approach in building a prototype.

  2. The Baden-Wuerttemberg office for listed buildings in Esslingen - architecture as a holistic approach; Landesdenkmalamt Baden-Wuerttemberg in Esslingen - Architektur als integrativer Ansatz

    Energy Technology Data Exchange (ETDEWEB)

    Reutter, O.

    2003-07-01

    Odilo Reutter Dipl. Ing., Architekt, BDA, Rathausplatz 7, 73728 Esslingen am Neckar Tel.: 0711/3508622, Fax: 0711/354450, E-mail: reutter rate at reutter-architektur.de. The headquarters of the regional office for listed buildings will move to the former Schelztor-Gymnasium in Esslingen in an attempt to bring the branch offices spread throughout the country under one roof. As late as the nineteenth century, the medieval city of Esslingen was characterised by city walls, towers and moats. With the advent of industrialisation, the city expanded to include the Weststadt district and its walls were dismantled and new buildings erected. The former Schelztor-Gymnasium stands at the historic crossroads of the city's expansion. A new detached building, in line with the existing one, will be added to the former nineteenth-century listed school building to accommodate ultra modern workspaces in laboratories, workshops and offices with high air-conditioning and lighting standards. The building will fulfil the following urban functions: 1. Extension of the existing historic parts of the building. 2. Creation of a link between the building and the Weststadt district as it was at the time of the city's nineteenth-century expansion 3. Spatial delimitation of the Martinstrasse axis. 4. Pivotal function; abandonment of the block development in favour of the single building block. (orig.)

  3. Measuring Instrument Constructs of Return Factors for Green Office Building Investments Variables Using Rasch Measurement Model

    Directory of Open Access Journals (Sweden)

    Isa Mona

    2016-01-01

    Full Text Available This paper is a preliminary study on rationalising green office building investments in Malaysia. The aim of this paper is attempt to introduce the application of Rasch measurement model analysis to determine the validity and reliability of each construct in the questionnaire. In achieving this objective, a questionnaire survey was developed consists of 6 sections and a total of 106 responses were received from various investors who own and lease office buildings in Kuala Lumpur. The Rasch Measurement analysis is used to measure the quality control of item constructs in the instrument by measuring the specific objectivity within the same dimension, to reduce ambiguous measures, and a realistic estimation of precision and implicit quality. The Rasch analysis consists of the summary statistics, item unidimensionality and item measures. A result shows the items and respondent (person reliability is at 0.91 and 0.95 respectively.

  4. As- built inventory of the office building with the use of terrestrial laser scanning

    Science.gov (United States)

    Przyborski, Marek; Tysiąc, Paweł

    2018-01-01

    Terrestrial Laser Scanning (TLS) is an efficient tool for building inventories. Based on the red- laser beam technology it is possible to provide the high accuracy data with complete spatial information about a scanned object. In this article, authors present the solution of use a TLS in as-built inventory of the office building. Based on the provided data, it is possible to evaluate the correctness of built details of a building and provide information for further construction works, for example an area needed for Styrofoam installation. The biggest problem in this research is that an error which equals over 1cm could generate costs, which could be a problem to cover by a constructor. Based on a complicated place of the construction works (centre of a city) it was a challenge to maintain the accuracy.

  5. As- built inventory of the office building with the use of terrestrial laser scanning

    Directory of Open Access Journals (Sweden)

    Przyborski Marek

    2018-01-01

    Full Text Available Terrestrial Laser Scanning (TLS is an efficient tool for building inventories. Based on the red- laser beam technology it is possible to provide the high accuracy data with complete spatial information about a scanned object. In this article, authors present the solution of use a TLS in as-built inventory of the office building. Based on the provided data, it is possible to evaluate the correctness of built details of a building and provide information for further construction works, for example an area needed for Styrofoam installation. The biggest problem in this research is that an error which equals over 1cm could generate costs, which could be a problem to cover by a constructor. Based on a complicated place of the construction works (centre of a city it was a challenge to maintain the accuracy.

  6. Development and Analysis of Desiccant Enhanced Evaporative Air Conditioner Prototype

    Energy Technology Data Exchange (ETDEWEB)

    Kozubal, E.; Woods, J.; Judkoff, R.

    2012-04-01

    This report documents the design of a desiccant enhanced evaporative air conditioner (DEVAP AC) prototype and the testing to prove its performance. Previous numerical modeling and building energy simulations indicate a DEVAP AC can save significant energy compared to a conventional vapor compression AC (Kozubal et al. 2011). The purposes of this research were to build DEVAP prototypes, test them to validate the numerical model, and identify potential commercialization barriers.

  7. Building-Related Symptoms among Office Employees Associated with Indoor Carbon Dioxide and Total Volatile Organic Compounds

    Directory of Open Access Journals (Sweden)

    Chung-Yen Lu

    2015-05-01

    Full Text Available This study investigated whether sick building syndrome (SBS complaints among office workers were associated with the indoor air quality. With informed consent, 417 employees in 87 office rooms of eight high-rise buildings completed a self-reported questionnaire for symptoms experienced at work during the past month. Carbon dioxide (CO2, temperature, humidity and total volatile organic compounds (TVOCs in each office were simultaneously measured for eight office hours using portable monitors. Time-averaged workday difference between the indoor and the outdoor CO2 concentrations (dCO2 was calculated as a surrogate measure of ventilation efficiency for each office unit. The prevalence rates of SBS were 22.5% for eye syndrome, 15.3% for upper respiratory and 25.4% for non-specific syndromes. Tiredness (20.9%, difficulty in concentrating (14.6%, eye dryness (18.7% were also common complaints. The generalized estimating equations multivariate logistic regression analyses showed that adjusted odds ratios (aORs and 95% confidence interval (CI per 100 ppm increase in dCO2 were significantly associated with dry throat (1.10, 95% CI = (1.00–1.22, tiredness (1.16, 95% CI = (1.04–1.29 and dizziness (1.22, 95% CI = (1.08–1.37. The ORs for per 100 ppb increases in TVOCs were also associated with upper respiratory symptoms (1.06, 95% CI = (1.04–1.07, dry throat (1.06, 95% CI = (1.03–1.09 and irritability (1.02, 95% CI = (1.01–1.04. In conclusion, the association between some SBS symptoms and the exposure to CO2 and total VOCs are moderate but may be independently significant.

  8. Light Guide Collector Prototype: Laboratory Testing

    Directory of Open Access Journals (Sweden)

    Jitka - Mohelnikova

    2017-12-01

    Full Text Available The article reviews the potential of light guide system equipped by a concentrator device capturing daylight applicable for illumination of building interiors and presents results of experiments on performance of its prototype. The main goal is focused on the comparison of traditional solutions and newly developed prototype of the light guide system and presents examination of its light transmission efficiency based on the laboratory experiments.

  9. Assessment of sick building syndrome among office workers in Shahid Sadoughi University of medical sciences in 2008

    Directory of Open Access Journals (Sweden)

    F. Nourani Yazdi

    2011-04-01

    Full Text Available Background and aims Building associated illnesses are a group of illnesses caused by physical or psychological conditions of workplace. One of theses illnesses is sick building syndrome (SBS which consists of a group of symptoms, including mucosal irritation, headache, fatigue, skin dryness and itching, and nausea that are temporally related to presence in a particular building. This study was designed to assess SBS and factors affecting it in central building of Shahid Sadoughi University of medical sciences.   Methods This is a cross-sectional study on workers of central building of Shahid Sadoughi University of medical sciences. The prevalence of SBS was determined using self-administered indoor air quality (IAQ questionnaire for office workers. All workers who worked at least one year in this building and had no other medical illnesses with similar symptoms to SBS, entered the study and the questionnaire was filled out for them. Data was analyzed using chi square test.   ResultsPrevalence of SBS among the workers of central building was 35.7% (34.8% in male and 36.9% in female workers. There was no significant association between prevalence of SBS and age, gender, duration of employment and level of education. The most frequent complaints mentioned by participants were fatigue and headache, and the most frequent causes were noise, inadequate physical space and crowded work environment.   Conclusion This survey showed a relatively high prevalence of SBS among office workers in this organization. So considering the effects of SBS on workers' function and productivity, it is recommended to reduce its causes, especially noise and inadequate space.

  10. 25 Years of cooling research in office buildings : Review for the integration of cooling strategies into the building façade (1990–2014)

    NARCIS (Netherlands)

    Prieto Hoces, A.I.; Knaack, U.; Klein, T.; Auer, T

    2017-01-01

    This paper seeks to present a panorama of cooling related research in office buildings, categorising reported research experiences from the past 25 years in order to identify knowledge gaps and define current paths and trends for further exploration. The general goal behind this research is to

  11. Human Perception, SBS Sympsoms and Performance of Office Work during Exposure to Air Polluted by Building Materials and Personal Computers

    DEFF Research Database (Denmark)

    Bako-Biro, Zsolt

    The present thesis deals with the impact of polluted air from building materials and personal computers on human perception, Sick Building Syndrome (SBS) symptoms and performance of office work. These effects have been studies in a series of experiments that are described in two different chapters...

  12. Optimum operation of heating systems in office buildings. Automated error detection and analysis improves running building operation; Heizsysteme in Buerogebaeuden optimal betreiben. Automatisierte Fehlererkennung und -analyse verbessert den laufenden Gebaeudebetrieb

    Energy Technology Data Exchange (ETDEWEB)

    Friedrich, Uwe

    2013-06-01

    Since 2010, various institutes, universities and consultancy companies have been conducting research on automated operation optimisation in larger buildings. For this purpose, they have developed procedures for commissioning and monitoring building services equipment systems, firstly for large heat supply units. These are currently being used and evaluated on an ongoing basis in seven office and school buildings. The aim is to make significant energy and cost savings, and to improve the level of convenience in the building.

  13. Improving PAQ and comfort conditions in Spanish office buildings with passive climate control

    Energy Technology Data Exchange (ETDEWEB)

    Orosa, Jose A.; Baalina, A. [Departamento de Energia y P.M. Escuela Tecnica Superior de N. y M, Universidade da Coruna, Paseo de Ronda 51, P.C.:15011 A Coruna (Spain)

    2009-03-15

    Some researchers have demonstrated that passive moisture transfer between indoor air and hygroscopic structures has the potential to moderate variations of indoor air relative humidity and, thus, to improve comfort and PAQ [Simonson CJ, Salonvaara M, Ojalen T. The effect of structures on indoor humidity-possibility to improve comfort and perceived air quality. Indoor Air 2002; 12: 243-51; Simonson CJ, Salonvaara M, Ojalen T. Improving indoor climate and comfort with wooden structures. Espoo 2001. Technical Research Centre of Finland, VTT Publications 431.200p+app 91p]. The main objective of this study is to show the internal wall coating effect on indoor air conditions and, as a consequence of this, in comfort conditions and PAQ. In a previous paper [Orosa JA, Baalina A. Passive climate control in Spanish office buildings for long periods of time. Building and Environment 2008], we analysed the influence of permeable and impermeable materials on indoor air conditions, during the unoccupied period, in 25 office buildings in different seasons. Results obtained lead us to conclude that real coverings such as permeable, semi-permeable and impermeable types, present different behavioural patterns in indoor air conditions. Furthermore, we concluded that an absorbent structure will moderate relative humidity indoors. In this paper, we study this indoor relative humidity effect on local thermal discomfort, due to decreased respiratory cooling, and indoor ambience acceptability for the early hours of morning applying PD and Acc models [Toftum J, Jorgensen AS, Fanger PO. Upper limits for indoor air humidity to avoid uncomfortably humid skin. Energy and buildings 1998; 28: 1-13; Toftum J, Jorgensen AS, Fanger PO. Upper limits of air humidity for preventing warm respiratory discomfort. Energy and Buildings 1998; 28: 15-23] such as that proposed by Simonson et al. [The effect of structures on indoor humidity-possibility to improve comfort and perceived air quality. Indoor Air

  14. Building construction materials effect in tropical wet and cold climates: A case study of office buildings in Cameroon

    Directory of Open Access Journals (Sweden)

    Modeste Kameni Nematchoua

    2016-03-01

    Full Text Available This paper presents the results of an experimental study that was conducted in 15 office buildings in the humid and cold tropics during the working hours of the dry and rainy seasons in Cameroon. This was with the aim to study the effects that local and imported materials had on indoor air quality. To achieve this objective, the adaptive model approach has been selected. In accordance with the conditions of this model, all workers were kept in natural ventilation and, in accordance with the general procedure, a questionnaire was distributed to them, while variables, like air temperature, wind speed, and relative humidity were sampled. The results showed a clear agreement between expected behaviour, in accordance with the characteristics of building construction, and its real indoor ambience once they were statistically analysed. On the other hand, old buildings showed a higher percentage of relative humidity and a lower degree of indoor air temperature. Despite this, local thermal comfort indices and questionnaires showed adequate indoor ambience in each group of buildings, except when marble was used for external tiling. The effect of marble as an external coating helps to improve indoor ambience during the dry season. This is due to more indoor air and relative humidity being accumulated. At the same time, these ambiences are degraded when relative humidity is higher. Finally, these results should be taken cognisance of by architects and building designers in order to improve indoor environment, and overcome thermal discomfort in the Saharan area.

  15. Assessment of the Fire Risk Levels in an Office Building and a Nightclub with Prescriptive Designs

    DEFF Research Database (Denmark)

    Yilmaz, D.; Steffensen, F.B.; Jomaas, Grunde

    2014-01-01

    A comparison of the risk level of an office building and a nightclub with code compliant prescriptive designs was conducted in order to evaluate whether an uniform safety level of the two occupancy types can be established. A risk assessment method using Monte Carlo simulations and 1- and 2-zone......-movement time and the movement time were adjusted for the required safe egress time (RSET) of the nightclub. The number of simulations required in order to obtain reliable results was considered sufficient at 20,000. The comparison of the risk profiles of the nightclub and the office building showed significant...... difference in risk levels, with that of the nightclub being substantially higher. The higher risk level in the nightclub is caused by a relatively fast mean value of the fire growth rate and the high number of occupants. Hence, the requirements in the prescriptive code do not ensure a similar safety level...

  16. Mechatronic Prototype of Parabolic Solar Tracker

    Directory of Open Access Journals (Sweden)

    Carlos Morón

    2016-06-01

    Full Text Available In the last 30 years numerous attempts have been made to improve the efficiency of the parabolic collectors in the electric power production, although most of the studies have focused on the industrial production of thermoelectric power. This research focuses on the application of this concentrating solar thermal power in the unexplored field of building construction. To that end, a mechatronic prototype of a hybrid paraboloidal and cylindrical-parabolic tracker based on the Arduido technology has been designed. The prototype is able to measure meteorological data autonomously in order to quantify the energy potential of any location. In this way, it is possible to reliably model real commercial equipment behavior before its deployment in buildings and single family houses.

  17. THE DESIGN OF A MODULAR WIND TURBINE MEANT FOR HOUSES AND OFFICE BUILDINGS

    Directory of Open Access Journals (Sweden)

    RĂDUICĂ Felix

    2016-11-01

    Full Text Available This paper describes a new wind turbine design which can be implemented for home, office and public buildings. Also, this article presents specific steps taken by the designer to develop the product. A honeycomb design has been implemented for modularity reasons. Certain measures have been taken to ensure the quality of the design including, but not limited to: an emphasis on design principles, product development and shapes described by and found in nature.

  18. Project management of the build of the shore test facility for the prototype of PWR II

    International Nuclear Information System (INIS)

    Clarkson, D.T.

    1987-01-01

    The PWR II is a new design of nuclear steam raising plant for the Royal Navy's submarines. It features improved engineering for safety, increased power, increased shock resistance, reduced noise transmission to sea and reduced manning requirement. It is to be tested in a new prototype testing facility, the Shore Test Facility, which is a section of submarine hull containing a prototype of the nuclear steam raising plant and its support system. It is installed at the Vulcan Naval Reactor Test establishment at Dounreay in Scotland. The function of the establishment is to test new designs of core and reactor plant, validate the mathematical models used in their design, develop improved methods of operation and maintenance of the plant and test new items of equipment. The Shore Test Facility was built in large sections at Barrow-in-Furness and transported to Scotland. The project management for the construction of the Shore Test Facility is explained. It involves personnel from the Royal Navy, and a large number of people working for the contractors involved in the buildings, transportation, operation and maintenance of the Facility. (U.K.)

  19. Developing a Philippine Cancer Grid. Part 1: Building a Prototype for a Data Retrieval System for Breast Cancer Research Using Medical Ontologies

    Science.gov (United States)

    Coronel, Andrei D.; Saldana, Rafael P.

    Cancer is a leading cause of morbidity and mortality in the Philippines. Developed within the context of a Philippine Cancer Grid, the present study used web development technologies such as PHP, MySQL, and Apache server to build a prototype data retrieval system for breast cancer research that incorporates medical ontologies from the Unified Medical Language System (UMLS).

  20. Evaluation of Various Retrofitting Concepts of Building Envelope for Offices Equipped with Large Radiant Ceiling Panels by Dynamic Simulations

    Directory of Open Access Journals (Sweden)

    Sabina Jordan

    2015-09-01

    Full Text Available In order to achieve significant savings in energy and an improved level of thermal comfort in retrofitted existing buildings, specific retrofitting concepts that combine new technologies and design need to be developed and implemented. Large radiant surfaces systems are now among the most promising future technologies to be used both in retrofitted and in new low-energy buildings. These kinds of systems have been the topic of several studies dealing with thermal comfort and energy utilization, but some specific issues concerning their possible use in various concepts for retrofitting are still poorly understood. In the present paper, some results of dynamic simulations, with the transient system simulation tool (TRNSYS model, of the retrofitted offices equipped with radiant ceiling panels are presented and thoroughly analysed. Based on a precise comparison of the results of these simulations with actual measurements in the offices, certain input data for the model were added, so that the model was consequently validated. The model was then applied to the evaluation of various concepts of building envelopes for office retrofitting. By means of dynamic simulations of indoor environment it was possible to determine the benefits and limitations of individual retrofitting concepts. Some specific parameters, which are relevant to these concepts, were also identified.

  1. Scotts Valley Energy Office and Human Capacity Building that will provide energy-efficiency services and develop sustainable renewable energy projects.

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Temashio [Scotts Valley Band of Pomo Indians

    2013-06-28

    The primary goal of this project is to develop a Scotts Valley Energy Development Office (SVEDO). This office will further support the mission of the Tribe's existing leadership position as the DOE Tribal Multi-County Weatherization Energy Program (TMCWEP) in creating jobs and providing tribal homes and buildings with weatherization assistance to increase energy efficiency, occupant comfort and improved indoor air quality. This office will also spearhead efforts to move the Tribe towards its further strategic energy goals of implementing renewable energy systems through specific training, resource evaluation, feasibility planning, and implementation. Human capacity building and continuing operations are two key elements of the SVEDO objectives. Therefore, the project will 1) train and employ additional Tribal members in energy efficiency, conservation and renewable resource analyses and implementation; 2) purchase materials and equipment required to implement the strategic priorities as developed by the Scotts Valley Tribe which specifically include implementing energy conservation measures and alternative energy strategies to reduce energy costs for the Tribe and its members; and 3) obtain a dedicated office and storage space for ongoing SVEDO operations.

  2. Coloured solar collectors. Phase II : from laboratory samples to collector prototypes. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, A; Roecker, Ch; Chambrier, E de; Munari Probst, M

    2007-07-01

    This illustrated final report for the Swiss Federal Office of Energy (SFOE) deals with the second phase of a project concerning the architectural integration of glazed solar collectors into the facades of buildings for heat production. The factors that limit the integration of photovoltaic panels in facades are discussed. The authors state that, for a convincing demonstration, sufficiently large samples and high quality levels are needed. The sol-gel deposition of the multi-layered coatings on A4-sized glass panes demonstrated in the laboratory by EPFL-LESO are discussed. The coatings produced exhibit a coloured reflection in combination with a high solar transmittance, a homogenous appearance, and are free of visible defects. Film hardening by UV exposure is discussed: This should result in the speeding up of the sol-gel process and thus save energy, thereby significantly reducing costs. Collaboration with industry is discussed in which full-scale glass panes are to be coated with novel multiple layers. The novel glazing is to be integrated into first prototype collectors. The manufacturing and test processes for the prototypes manufactured are discussed in detail.

  3. Incidence of polybrominated diphenyl ethers in central air conditioner filter dust from a new office building

    Energy Technology Data Exchange (ETDEWEB)

    Ni Honggang; Cao Shanping; Chang Wenjing [Shenzhen Key Laboratory of Circular Economy, Shenzhen Graduate School, Peking University, Shenzhen 518055 (China); Zeng Hui, E-mail: huizeng0608@gmail.com [Shenzhen Key Laboratory of Circular Economy, Shenzhen Graduate School, Peking University, Shenzhen 518055 (China); Department of Ecology, College of Urban and Environmental Sciences, Peking University, Beijing 100871 (China)

    2011-07-15

    This study examined polybrominated diphenyl ethers (PBDEs) in central air conditioner filter (CACF) dust from a new office building in Shenzhen, China. Human exposure to PBDE via dust inhalation and ingestion were also estimated. PBDEs level in CACF dust was lower than those in the other countries and regions. Approximately 0.671 pg/kg bw/day PM{sub 2.5} (Particulate Matter up to 2.5 {mu}m in size) bounded {Sigma}{sub 15}PBDEs can be inhaled deep into the lungs and 4.123 pg/kg bw/day PM{sub 10} (Particulate Matter up to 10 {mu}m in size) bounded {Sigma}{sub 15}PBDEs tend to be deposited in the upper parts of the respiratory system. The average total intake of {Sigma}{sub 15}PBDEs via dust inhalation and ingestion for adults reached {approx}141 pg/kg bw/day in this building. This value was far below the reference dose (RfD) recommended by United States Environmental Protection Agency. Human exposure to PBDEs via dust inhalation and ingestion in the new building is less than the old ones. - Highlights: > Human exposure to PBDEs via dust inhalation and ingestion in the new building is less than that in the old ones. > PBDE emissions from indoor sources can be expected to continue for a long time as the PBDE-containing products in offices were to be kept many years. > The household consumer products, especially computers, are the main sources of PBDEs in central air conditioner filter dust. > Further studies are needed to fully understand the emission mechanism of PBDE from indoor consumer products. - PBDEs in central air conditioner filter dust from a new building were investigated

  4. Incidence of polybrominated diphenyl ethers in central air conditioner filter dust from a new office building

    International Nuclear Information System (INIS)

    Ni Honggang; Cao Shanping; Chang Wenjing; Zeng Hui

    2011-01-01

    This study examined polybrominated diphenyl ethers (PBDEs) in central air conditioner filter (CACF) dust from a new office building in Shenzhen, China. Human exposure to PBDE via dust inhalation and ingestion were also estimated. PBDEs level in CACF dust was lower than those in the other countries and regions. Approximately 0.671 pg/kg bw/day PM 2.5 (Particulate Matter up to 2.5 μm in size) bounded Σ 15 PBDEs can be inhaled deep into the lungs and 4.123 pg/kg bw/day PM 10 (Particulate Matter up to 10 μm in size) bounded Σ 15 PBDEs tend to be deposited in the upper parts of the respiratory system. The average total intake of Σ 15 PBDEs via dust inhalation and ingestion for adults reached ∼141 pg/kg bw/day in this building. This value was far below the reference dose (RfD) recommended by United States Environmental Protection Agency. Human exposure to PBDEs via dust inhalation and ingestion in the new building is less than the old ones. - Highlights: → Human exposure to PBDEs via dust inhalation and ingestion in the new building is less than that in the old ones. → PBDE emissions from indoor sources can be expected to continue for a long time as the PBDE-containing products in offices were to be kept many years. → The household consumer products, especially computers, are the main sources of PBDEs in central air conditioner filter dust. → Further studies are needed to fully understand the emission mechanism of PBDE from indoor consumer products. - PBDEs in central air conditioner filter dust from a new building were investigated

  5. Solar heating and hot water system installed at office building, One Solar Place, Dallas, Texas. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1980-06-01

    This document is the Final Report of the Solar Energy System Installed at the First Solar Heated Office Building, One Solar Place, Dallas, Texas. The Solar System was designed to provide 87 percent of the space heating needs, 100 percent of the potable hot water needs and is sized for future absorption cooling. The collection subsystem consists of 28 Solargenics, series 76, flat plate collectors with a total area of 1596 square feet. The solar loop circulates an ethylene glycol-water solution through the collectors into a hot water system heat exchanger. The hot water storage subsystem consists of a heat exchanger, two 2300 gallon concrete hot water storage tanks with built in heat exchangers and a back-up electric boiler. The domestic hot water subsystem sends hot water to the 10,200 square feet floor area office building hot water fixtures. The building cold water system provides make-up to the solar loop, the heating loop, and the hot water concrete storage tanks. The design, construction, cost analysis, operation and maintenance of the solar system are described. The system became operational July 11, 1979.

  6. Controlling Capital Costs in High Performance Office Buildings: A Review of Best Practices for Overcoming Cost Barriers

    Energy Technology Data Exchange (ETDEWEB)

    Pless, S.; Torcellini, P.

    2012-05-01

    This paper presents a set of 15 best practices for owners, designers, and construction teams of office buildings to reach high performance goals for energy efficiency, while maintaining a competitive budget. They are based on the recent experiences of the owner and design/build team for the Research Support Facility (RSF) on National Renewable Energy Facility's campus in Golden, CO, which show that achieving this outcome requires each key integrated team member to understand their opportunities to control capital costs.

  7. Feasibility of ground coupled heat pumps in office buildings: A China study

    International Nuclear Information System (INIS)

    Zhou, Zhihua; Zhang, Zhiming; Chen, Guanyi; Zuo, Jian; Xu, Pan; Meng, Chong; Yu, Zhun

    2016-01-01

    Highlights: • Feasibility of GCHPs in office buildings was assessed in various climatic regions. • Performance of GCHPs was compared with traditional heating and cooling techniques. • Ratio of the heating to cooling load has significant impacts on operation of GCHPs. - Abstract: Ground coupled heat pumps (GCHPs) have been widely applied in China due to its environmental friendliness and energy efficiency. However, it may not be appropriate in all geographical areas because a variety of factors (e.g. original soil temperature, peak cooling and heating load, and running time) vary significantly. Typical office buildings were selected from five cities that are located in different climatic regions. The QUick Energy Simulation Tool (e-QUEST) was utilized to simulate the cooling and heating load. Similarly, the Transient System Simulation Program (TRNSYS) was employed to simulate the 20-year variation of the average soil temperature and the Coefficient of Performance (COP) of GCHP units. Consequently, the feasibility of the GCHPs in different regions was analyzed. The results show that GCHP system is feasible in severe cold B regions such as Shenyang and cold regions such as Beijing as both cold and heat sources because of its energy efficiency. From the economy and operation performance’s perspective, GCHP system is not feasible in severe cold A regions such as Harbin; hot-summer and cold-winter regions such as Nanjing; and hot-summer and warm-winter region such as Guangzhou. This is due to the poor energy efficiency of the system, mainly attributed to a large gap between cumulative energy consumption for cooling and for heating. Comprehensive analysis of experiment results showed that the GCHP system of case building in cold region can operate stably in long term with a high efficiency when the ratio of annual cumulative cooling energy consumption to annual cumulative heating energy consumption ranges from 0.2:1 to 5:1. In severe cold B regions, GCHP system

  8. Habitat Demonstration Unit Project: Leadership and Management Strategies for a Rapid Prototyping Project

    Science.gov (United States)

    Kennedy, Kriss J.; Toup, Larry; Gill, Tracy; Tri, Terry; Howe, Scott; Smitherman, David

    2011-01-01

    This paper gives an overview of the National Aeronautics and Space Administration (NASA) led multi-center Habitat Demonstration Unit (HDU) project leadership and management strategies being used by the NASA HDU team for a rapid prototyping project. The HDU project team constructed and tested an analog prototype lunar surface habitat/laboratory called the Pressurized Excursion Module (PEM) during 2010. The prototype unit subsystems were integrated in a short amount of time, utilizing a tiger team rapid prototyping approach that brought together over 20 habitation-related technologies and innovations from a variety of NASA centers. This paper describes the leadership and management strategies as well as lessons learned pertaining to leading and managing a multi-center diverse team in a rapid prototype environment. The PEM configuration went from a paper design to an operational surface habitat demonstration unit in less than 12 months. The HDU project is part of the strategic plan from the Exploration Systems Mission Directorate (ESMD) Directorate Integration Office (DIO) and the Exploration Mission Systems Office (EMSO) to test destination elements in analog environments. The 2011 HDU-Deep Space Habitat (DSH) configuration will build upon the PEM work, and emphasize validity of crew operations (remote working and living), EVA operations, mission operations, logistics operations, and science operations that might be required in a deep space context for Near Earth Object (NEO) exploration mission architectures. The 2011 HDU-DSH will be field-tested during the 2011 Desert Research and Technologies Studies (DRaTS) field tests. The HDU project is a "technology-pull" project that integrates technologies and innovations from multiple NASA centers. This project will repurpose the HDU 2010 demo unit that was field tested in the 2010 DRaTS, adding habitation functionality to the prototype unit. This paper will describe the strategy of establishing a multi-center project

  9. Using prototyping in software development

    OpenAIRE

    Šinkovec, Miha

    2010-01-01

    Today the business system changers faster than the usual conventional cascade life cycle. Because of that, we can conclude, that today's programming system will no longer be presented as the answer to this topic in the developing age of ever changing user requirements. Neither increased performance or higher productivity will decrease the problem. The appropriate solution to this stated problem is prototyping. Instead of building and developing the whole system, we build a module that can...

  10. [Schools, office buildings, leisure settings: diversity of indoor air quality issues. Global review on indoor air quality in these settings].

    Science.gov (United States)

    Mandin, C; Derbez, M; Kirchner, S

    2012-07-01

    This review provides a global overview of indoor air quality issues in schools, office buildings and recreational settings. It presents the most recent scientific publications and the on-going work conducted in France in the frame of the indoor air quality Observatory. Monitoring campaigns on indoor air quality in schools have been carried out in the recent years in Europe. However, few studies have specifically addressed the role of exposure in these buildings on children's health. Indoor air quality in office buildings has been little studied so far. However, some specificities, such as emissions from electronic devices, frequent cleaning, impossibility to open windows in high-rise buildings, for example, should be examined and their role on the health and comfort studied. Finally, even if the time spent in recreational settings is short, the quality of indoor air should also be considered because of specific pollution. This is the case of indoor swimming pools (exposure to chlorination byproducts) and ice-rinks (exposure to exhaust from machines used to smooth the ice). Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  11. Modeling and simulation to determine the potential energy savings by implementing cold thermal energy storage system in office buildings

    International Nuclear Information System (INIS)

    Rismanchi, B.; Saidur, R.; Masjuki, H.H.; Mahlia, T.M.I.

    2013-01-01

    Highlights: • Simulating the CTES system behavior based on Malaysian climate. • Almost 65% of power is used for cooling for cooling the office buildings, every day. • The baseline shows an acceptable match with real data from the fieldwork. • Overall, the energy used for full load storage is much than the conventional system. • The load levelling storage strategy has 3.7% lower energy demand. - Abstract: In Malaysia, air conditioning (AC) systems are considered as the major energy consumers in office buildings with almost 57% share. During the past decade, cold thermal energy storage (CTES) systems have been widely used for their significant economic benefits. However, there were always doubts about their energy saving possibilities. The main objective of the present work is to develop a computer model to determine the potential energy savings of implementing CTES systems in Malaysia. A case study building has been selected to determine the energy consumption pattern of an office building. In the first step the building baseline model was developed and validated with the recorded data from the fieldwork. Once the simulation results reach an acceptable accuracy, different CTES system configuration was added to the model to predict their energy consumption pattern. It was found that the overall energy used by the full load storage strategy is considerably more than the conventional system. However, by applying the load leveling storage strategy, and considering its benefits to reduce the air handling unit size and reducing the pumping power, the overall energy usage was almost 4% lower than the non-storage system. Although utilizing CTES systems cannot reduce the total energy consumption considerably, but it has several outstanding benefits such as cost saving, bringing balance in the grid system, reducing the overall fuel consumption in the power plants and consequently reducing to total carbon footprint

  12. Metamorphosis of Shell's office buildings in The Hague, Netherlands; Metamorfose Shell Den Haag

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, G.F.A. [Valstar Simonis, Apeldoorn (Netherlands); Van Mierlo, W.J.M. [Shell, Den Haag (Netherlands)

    2008-07-15

    In a project to renovate the Shell office buildings in The Hague, Netherlands, the new buildings are served by a new power plant based on a heat pump and an underground thermal storage system. Use of a heating curve in the high-temperature heating system of the renovated building sections made it possible to create a link between the new low-temperature heating system and the existing high-temperature heating system. A similar link was created for cooling. [Dutch] Bij de herstructurering van het gebouwencomplex van Shell in Den Haag is voor de nieuwe gebouwen een energiecentrale met een warmtepomp en ondergronds energieopslagsysteem gerealiseerd. Door gebruik te maken van een stooklijn in het hooggestookte verwarmingssysteem van de gerenoveerde bouwdelen, is een koppeling aangebracht tussen het nieuwe Iaagtemperatuur verwarmingssysteem en het bestaande hooggestookte verwarmingssysteem. Ook voor de koeling is een dergelijke koppeling gemaakt.

  13. Analysis of energy efficiency retrofit schemes for heating, ventilating and air-conditioning systems in existing office buildings based on the modified bin method

    International Nuclear Information System (INIS)

    Wang, Zhaoxia; Ding, Yan; Geng, Geng; Zhu, Neng

    2014-01-01

    Highlights: • A modified bin method is adopted to propose and optimize the EER schemes. • A case study is presented to demonstrate the analysis procedures of EER schemes. • Pertinent EER schemes for HVAC systems are proposed for the object building. - Abstract: Poor thermal performance of building envelop and low efficiencies of heating, ventilating and air-conditioning (HVAC) systems can always be found in the existing office buildings with large energy consumption. This paper adopted a modified bin method to propose and optimize the energy efficiency retrofit (EER) schemes. An existing office building in Tianjin was selected as an example to demonstrate the procedures of formulating the design scheme. Pertinent retrofit schemes for HVAC system were proposed after the retrofit of building envelop. With comprehensive consideration of energy efficiency and economic benefits, the recommended scheme that could improve the overall energy efficiency by 71.20% was determined

  14. Reducing Plug and Process Loads for a Large Scale, Low Energy Office Building: NREL's Research Support Facility; Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Lobato, C.; Pless, S.; Sheppy, M.; Torcellini, P.

    2011-02-01

    This paper documents the design and operational plug and process load energy efficiency measures needed to allow a large scale office building to reach ultra high efficiency building goals. The appendices of this document contain a wealth of documentation pertaining to plug and process load design in the RSF, including a list of equipment was selected for use.

  15. Environment-friendly building complex of the BBVA bank in Madrid, Spain. Sustainable and healthy indoor climate in a new office building; Spaans BBVA-cornplex milieuvriendelijk gebouwd. Duurzaam en gezond binnenklimaat nieuw hoofdkantoor

    Energy Technology Data Exchange (ETDEWEB)

    Petersen, G. [Swegon, Capelle aan den IJssel (Netherlands)

    2011-03-15

    In the design and construction of the new office building of the Spanish bank BBVA (Madrid) sustainability and environmental effects were important aspects. The office building complex will certified by the American company Leed Gold. The energy efficient installations are made possible by Eurovent-certified heat recovery units and comfort units. [Dutch] Bij de bouw van het nieuwe hoofdkantoor van de Spaanse bank BBVA in Madrid staan duurzaamheid en milieuvriendelijkheid hoog in het vaandel. Het complex zal na de oplevering worden gecertificeerd conform het Amerikaanse Leed Gold. De energiezuinige installatie wordt mede mogelijk gemaakt door Eurovent-gecertificeerde wtw-units en comfortunits.

  16. Out of Office : A Study on the Cause of Office Vacancy and Transformation as a Means to Cope and Prevent

    NARCIS (Netherlands)

    Remøy, H.

    2010-01-01

    Office building vacancy is becoming an increasingly visible part of the cityscape. Billboards shout “for rent” and office locations look abandoned even in the middle of the day. Still, new office buildings and locations are being developed, adding up to the built environment. As hardly any office

  17. Experimental and modelling analysis of an office building HVAC system based in a ground-coupled heat pump and radiant floor

    International Nuclear Information System (INIS)

    Villarino, José Ignacio; Villarino, Alberto; Fernández, Francisco Ángel

    2017-01-01

    Highlights: • A case study of a geothermal heat pump in an office building. • A numerical model in EnergyPlus is validated by experimental results. • An energy, economic and environmental analysis is presented. • A comparison with other technologies demonstrates the potential of the system. - Abstract: This paper shows the evaluation of the performance of a ground-coupled heat pump system monitored building providing heating, ventilating and air conditioning to an office building located in Madrid, in Spain. The system consists of one borehole exchanger, heat pump unit, radiant floor system, mechanical ventilation and data control system. A simulation model was performed with EnergyPlus software and validated. The analyzed period corresponds to the most unfavorable weather conditions in heating and cooling mode. The coefficient of performance obtained in heating and cooling mode was 3.86/5.29, considering all the energy consumption elements of the building and the thermal demand corresponding to an office operation. The CO_2 emissions obtained with a value of 34.68 kg corresponding to the period analyzed represents a low CO_2 emission system. The monitored temperatures reached set point values of 22 °C/25 °C, considered as acceptable comfort temperatures. The values obtained in the validated simulation model presented a deviation of 2% respected experimental results in heating and cooling mode. A comparative of COP_s_y_s and CO_2 emissions with other technologies is performed in order to analyze GCHP compared to other available technologies. The GCHP system is presented as a technology that can fully supply the HVAC conditions for a building and environmentally friendly.

  18. Evaluating the use heat pipe for dedicated ventilation of office buildings in Hong Kong

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Lian [Department of Building Services Engineering, Hong Kong Polytechnic University, Hung Hom (Hong Kong); Lee, W.L., E-mail: bewll@polyu.edu.h [Department of Building Services Engineering, Hong Kong Polytechnic University, Hung Hom (Hong Kong)

    2011-04-15

    Research highlights: {yields} Heat pipe dedicated for outdoor air treatment (HPDV system) was investigated. {yields} Investigations were based on cooling demand of 10 existing office buildings in HK. {yields} HPDV system could save energy use for 70% of the air-conditioned hours. {yields} HPDV system could save 1.2% to 7.9% of annual energy use for air-conditioning. {yields} Heat pipe of 57% effectiveness is the best in achieving energy saving objectives. -- Abstract: Recent research studies advocates decoupling dehumidification from cooling to improve indoor air quality and reduce energy consumption. The feasible use of heat pipe at the air handler dedicated for outdoor air treatment (HPDV system) in accomplishing this objective is investigated in this study. To evaluate the performance and the energy saving potential of the proposed HPDV system, the design parameters of 75 Grade A office buildings in Hong Kong were collected. Ten representative buildings were subsequently identified for further study to achieve a confidence level of 95%. The annual cooling load profiles of the 10 representative buildings were simulated by the use of HTB2. Based on the realistic cooling load profiles and the heat pipes of effectiveness 0.35-0.6, the proposed HPDV system in achieving the intended objectives were evaluated. It was found that the savings for the 10 representative buildings were comparable. The reduction in cooling and reheating energy was between 23 and 44 kWh/m{sup 2}, which corresponds to 1.2% and 7.9% saving in annual energy use for air-conditioning. The results indicate that HP of different effectiveness can be applied to save energy for over 70% of the air-conditioned hours; of which only 0.03-6.3% of the time the decoupling objective cannot be achieved (abbreviated as NHRS). Based on the results of the study, a simplified model relating NHRS with heat pipe effectiveness has been established. The model can help designers more quickly determine how NHRS can be

  19. Solar envelope concepts: moderate density building applications. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Knowles, R.L.; Berry, R.D.

    1980-04-01

    Solar energy utilization in urban areas requires public guarantees that all property owners have direct access to the sun. The study examines the implications of this premise in relation to the need for cities to also encourage or accommodate rebuilding and future development. The public policy mechanism for guaranteeing solar access is conceptualized as a solar zoning envelope that allows the largest possible building bulk on a land parcel without shadowing neighboring properties during specified times. Step-by-step methods for generating solar envelopes are described with extensive drawings, showing a variety of urban platting and lot configurations. Development and design possibilities are examined on a selected set of Los Angeles sites with typically diverse urban characteristics. Envelope attributes suitable for encouraging moderate-density commercial and residential building are examined in the context of two hypothetical but realistic development programs: one for speculative office buildings and one for condominium housing. Numerous illustrations of envelope forms and prototypical building designs are provided. The results of development simulation studies on all test sites are tabulated to show building bulk, density, land-coverage and open space characteristics obtainable under the hypothesized envelopes.

  20. An office building used as a federal test bed for energy-efficient roofs

    Energy Technology Data Exchange (ETDEWEB)

    McLain, H.A.; Christian, J.E.

    1995-08-01

    The energy savings benefits of re-covering the roof of an existing federal office building with a sprayed polyurethane foam system are documented. The building is a 12,880 ft{sup 2} (1,197 m{sup 2}), 1 story, masonry structure located at the Oak Ridge National Laboratory (ORNL), Oak Ridge, TN. Prior to re-covering, the roof had a thin fiberglass insulation layer, which had become partially soaked because of water leakage through the failed built-up roof membrane. The average R-value for this roof measured at 2 hr{center_dot}ft{sup 2}{center_dot}{degrees}F/Btu (0.3 m{sup 2} {center_dot}K/W). After re-covering the roof, it measured at 13 hr{center_dot}ft{sup 2}{degrees}F/Btu (2.3 m{sup 2}{center_dot}K/W). The building itself is being used as a test bed to document the benefits of a number of energy efficiency improvements. As such, it was instrumented to measure the half-hourly energy consumption of the whole building and of the individual rooftop air conditioners, the roof heat fluxes and the interior air and roof temperatures. These data were used to evaluate the energy effectiveness of the roof re-covering action. The energy savings analysis was done using the DOE-2.lE building simulation program, which was calibrated to match the measured data. The roof re-covering led to around 10% cooling energy savings and around 50% heating energy savings. The resulting energy cost reductions alone are not sufficient to justify re-covered roofs for buildings having high internal loads, such as the building investigated here. However the energy savings do contribute significantly to the measure`s Savings-to-Investment Ratio (SIR).

  1. 78 FR 16275 - Extension of the Duration of Programmatic Agreements Based on the Department of Energy Prototype...

    Science.gov (United States)

    2013-03-14

    ... Based on the Department of Energy Prototype Programmatic Agreement for Its Weatherization Assistance... Department of Energy Prototype Programmatic Agreement for its Weatherization Assistance Program, State Energy... under the prototype Programmatic Agreement (PA) for the Office of Weatherization and Intergovernmental...

  2. Robotic buildings(s)

    NARCIS (Netherlands)

    Bier, H.H.

    2014-01-01

    Technological and conceptual advances in fields such as artificial intelligence, robotics, and material science have enabled robotic building to be in the last decade prototypically implemented. In this context, robotic building implies both physically built robotic environments and robotically

  3. Development of a new controller for simultaneous heating and cooling of office buildings

    DEFF Research Database (Denmark)

    Maccarini, Alessandro; Afshari, Alireza; Hultmark, Göran

    2016-01-01

    by signals of actual room air temperatures and return water temperature. Depending on the minimum and maximum air temperatures in the rooms, the supply water temperature was set by adjusting the return water temperature with two offsets, one for heating demand and one for cooling demand. The behaviour......This paper aims to develop a new controller to regulate the supply water temperature of a room-temperature loop integrated in a novel HVAC for office buildings. The main feature of the room-temperature loop is its ability to provide simultaneous heating and cooling by circulating water...... with a temperature of about 22 °C. Therefore, the same supply water temperature is delivered to all the thermal zones in the building, no matter whether a single zone needs heating or cooling. In previous studies, the supply water temperature varied between 20 °C and 23 °C, according to outdoor air temperature...

  4. Human Factors in Green Office Building Design: The Impact of Workplace Green Features on Health Perceptions in High-Rise High-Density Asian Cities

    Directory of Open Access Journals (Sweden)

    Fei Xue

    2016-10-01

    Full Text Available There is a growing concern about human factors in green building, which is imperative in high-rise high-density urban environments. This paper describes our attempts to explore the influence of workplace green features (such as green certification, ventilation mode, and building morphology on health perceptions (personal sensation, sensorial assumptions, healing performance based on a survey in Hong Kong and Singapore. The results validated the relationship between green features and health perceptions in the workplace environment. Remarkably, participants from the air-conditioned offices revealed significant higher concerns about health issues than those participants from the mixed-ventilated offices. The mixed-ventilation design performs as a bridge to connect the indoor environment and outdoor space, which enables people to have contact with nature. Additionally, the preferred building morphology of the workplace is the pattern of a building complex instead of a single building. The complex form integrates the configuration of courtyards, podium gardens, green terrace, public plaza, and other types of open spaces with the building clusters, which contributes to better health perceptions. This research contributes to the rationalization and optimization of passive climate-adaptive design strategies for green buildings in high-density tropical or subtropical cities.

  5. Evaluating Economic and Environmental Aspects of Using Solar Panels on Multi-Angled Facades of Office Buildings

    DEFF Research Database (Denmark)

    Hannoudi, Loay Akram; Lauring, Gert Michael; Christensen, Jørgen Erik

    2017-01-01

    This paper is concerned with using solar panels as high-tech cladding materials on multi-angled facades for office buildings. The energy produced by the solar panels will be consumed inside the office rooms by cooling compressors, ventilation, lighting and office equipment. Each multi-angled facade...... unit is directed into two different orientations on a vertical axis (right and left), but not tilted up and down. The different facade orientations will optimize the use of solar radiation to produce the needed energy from the solar panels when placing them on the parapets of these facades......, PVBAT to calculate the cost of the electricity produced by the solar panels and evaluate the total amount of energy produced from these panels along with the ratio to the energy bought directly from the electricity grid. There is also an environmental evaluation for the system by calculating the CO2...

  6. Energy and cost associated with ventilating office buildings in a tropical climate.

    Science.gov (United States)

    Rim, Donghyun; Schiavon, Stefano; Nazaroff, William W

    2015-01-01

    Providing sufficient amounts of outdoor air to occupants is a critical building function for supporting occupant health, well-being and productivity. In tropical climates, high ventilation rates require substantial amounts of energy to cool and dehumidify supply air. This study evaluates the energy consumption and associated cost for thermally conditioning outdoor air provided for building ventilation in tropical climates, considering Singapore as an example locale. We investigated the influence on energy consumption and cost of the following factors: outdoor air temperature and humidity, ventilation rate (L/s per person), indoor air temperature and humidity, air conditioning system coefficient of performance (COP), and cost of electricity. Results show that dehumidification of outdoor air accounts for more than 80% of the energy needed for building ventilation in Singapore's tropical climate. Improved system performance and/or a small increase in the indoor temperature set point would permit relatively large ventilation rates (such as 25 L/s per person) at modest or no cost increment. Overall, even in a thermally demanding tropical climate, the energy cost associated with increasing ventilation rate up to 25 L/s per person is less than 1% of the wages of an office worker in an advanced economy like Singapore's. This result implies that the benefits of increasing outdoor air ventilation rate up to 25 L/s per person--which is suggested to provide for productivity increases, lower sick building syndrome symptom prevalence, and reduced sick leave--can be much larger than the incremental cost of ventilation.

  7. Study of electroless nickel plating on PerFactoryTM rapid prototype model

    OpenAIRE

    J.C. Rajaguru; C. Au, M. Duke

    2012-01-01

    This paper presents an investigation of electroless nickel plating on PerFactoryTM rapid prototype model built on PerFactoryTM R05 material. PerFactoryTM R05 is acrylic based photo sensitive resin. It is a popular material in rapid prototyping using PerFactoryTM method which employs addictive manufacturing technique to build prototypes for visual inspection, assembly etc. Metallization of such a prototype can extend the application envelop of the rapid prototyping technique as they can be use...

  8. Fungal colonization of fiberglass insulation in the air distribution system of a multi-story office building: VOC production and possible relationship to a sick building syndrome

    Science.gov (United States)

    Ahearn, D. G.; Crow, S. A.; Simmons, R. B.; Price, D. L.; Noble, J. A.; Mishra, S. K.; Pierson, D. L.

    1996-01-01

    Complaints characteristic of those for sick building syndrome prompted mycological investigations of a modern multi-story office building on the Gulf coast in the Southeastern United States (Houston-Galveston area). The air handling units and fiberglass duct liner of the heating, ventilating and air conditioning system of the building, without a history of catastrophic or chronic water damage, demonstrated extensive colonization with Penicillium spp and Cladosporium herbarum. Although dense fungal growth was observed on surfaces within the heating-cooling system, most air samples yielded fewer than 200 CFU m-3. Several volatile compounds found in the building air were released also from colonized fiberglass. Removal of colonized insulation from the floor receiving the majority of complaints of mouldy air and continuous operation of the units supplying this floor resulted in a reduction in the number of complaints.

  9. Technical basis for radiological release of Grand Junction Office Building 2. Volume 1, dose assessment

    International Nuclear Information System (INIS)

    Morris, R.; Warga, J.; Thorne, D.

    1997-07-01

    Building 2 on the US Department of Energy (DOE) Grand Junction Office (GJO) site is part of the GJO Remedial Action Program (GJORAP). During evaluation of Building 2 for determination of radiological release disposition, some inaccessible surface contamination measurements were detected to be greater than the generic surface contamination guidelines of DOE Order 5400.5 (which are functionally equivalent to US Nuclear Regulatory Commission [NRC] Regulatory Guide 1.86). Although the building is nominal in size, it houses the site telecommunications system, that is critical to continued GJO operations, and demolition is estimated at $1.9 million. Because unrestricted release under generic surface contamination guidelines is cost-prohibitive, supplemental standards consistent with DOE Order 5400.5 are being pursued. This report describes measurements and dose analysis modeling efforts to evaluate the radiation dose to members of the public who might occupy or demolish Building 2, a 2,480 square-foot (ft) building constructed in 1944. The north portion of the building was used as a shower facility for Manhattan Project uranium-processing mill workers and the south portion was a warehouse. Many originally exposed surfaces are no longer accessible for contamination surveys because expensive telecommunications equipment have been installed on the floors and mounted on panels covering the walls. These inaccessible surfaces are contaminated above generic contamination limits

  10. Energy analysis of an improved concept of integrated PV panels in an office building in central Greece

    Energy Technology Data Exchange (ETDEWEB)

    Zogou, Olympia; Stapountzis, Herricos [University of Thessaly, Mechanical Engineering Department, Volos (Greece)

    2011-03-15

    During the last decade, steel constructions with glazed facades became popular for commercial buildings in Greece. Moreover, expensive metal, natural stone, marble, ceramic, granite as well as special glass is employed for aesthetic and energy efficiency reasons. This creates opportunities for the introduction of Photovoltaic (PV) modules in double facades. PV modules on south-facing building walls are better placed at a distance from the wall to allow heat rejection and avoid overheating and efficiency loss. Exploiting the rejected heat of the PV modules is also a challenge. In this paper, we examine an improved concept of incorporating PV modules to the south facades of an office building, exploiting both the electricity produced and the heat rejected by the module, to increase building energy efficiency. The PV modules are integrated to the building wall by means of a double facade, which employs intervening ducts for ventilation purposes. The ducts are heating outdoor air, which is employed to cover the ventilation needs of the building, as well as a part of the heating loads. Simulations for typical winter and summer weather and solar insolation conditions are carried out to investigate the building's energy performance improvements. (author)

  11. Energy analysis of an improved concept of integrated PV panels in an office building in central Greece

    International Nuclear Information System (INIS)

    Zogou, Olympia; Stapountzis, Herricos

    2011-01-01

    During the last decade, steel constructions with glazed facades became popular for commercial buildings in Greece. Moreover, expensive metal, natural stone, marble, ceramic, granite as well as special glass is employed for aesthetic and energy efficiency reasons. This creates opportunities for the introduction of Photovoltaic (PV) modules in double facades. PV modules on south-facing building walls are better placed at a distance from the wall to allow heat rejection and avoid overheating and efficiency loss. Exploiting the rejected heat of the PV modules is also a challenge. In this paper, we examine an improved concept of incorporating PV modules to the south facades of an office building, exploiting both the electricity produced and the heat rejected by the module, to increase building energy efficiency. The PV modules are integrated to the building wall by means of a double facade, which employs intervening ducts for ventilation purposes. The ducts are heating outdoor air, which is employed to cover the ventilation needs of the building, as well as a part of the heating loads. Simulations for typical winter and summer weather and solar insolation conditions are carried out to investigate the building's energy performance improvements.

  12. A hybrid decision support system for sustainable office building renovation and energy performance improvement

    Energy Technology Data Exchange (ETDEWEB)

    Juan, Yi-Kai [Department of Architecture, National Taiwan University of Science and Technology (NTUST) (China); Center for Sustainable Development and Global Competitiveness, Stanford University (United States); Gao, Peng [Department of Traffic and Transportation Engineering, Tongji University (China); Wang, Jie [Center for Sustainable Development and Global Competitiveness, Stanford University (United States)

    2010-03-15

    Energy consumption of buildings accounts for around 20-40% of all energy consumed in advanced countries. Over the last decade, more and more global organizations are investing significant resources to create sustainably built environments, emphasizing sustainable building renovation processes to reduce energy consumption and carbon dioxide emissions. This study develops an integrated decision support system to assess existing office building conditions and to recommend an optimal set of sustainable renovation actions, considering trade-offs between renovation cost, improved building quality, and environmental impacts. A hybrid approach that combines A* graph search algorithm with genetic algorithms (GA) is used to analyze all possible renovation actions and their trade-offs to develop the optimal solution. A two-stage system validation is performed to demonstrate the practical application of the hybrid approach: zero-one goal programming (ZOGP) and genetic algorithms are adopted to validate the effectiveness of the algorithm. A real-world renovation project is introduced to validate differences in energy performance projected for the renovation solution suggested by the system. The results reveal that the proposed hybrid system is more computationally effective than either ZOGP or GA alone. The system's suggested renovation actions would provide substantial energy performance improvements to the real project if implemented. (author)

  13. Final Environmental Assessment for the construction and operation of an office building at the Stanford Linear Accelerator Center. Part 2

    International Nuclear Information System (INIS)

    1995-08-01

    The Department of Energy (DOE) has prepared an Environmental Assessment (EA), DOE/EA-1107, analyzing the environmental effects relating to the construction and operation of an office building at the Stanford Linear Accelerator Center (SLAC). SLAC is a national facility operated by Stanford University, California, under contract with DOE. The center is dedicated to research in elementary particle physics and in those fields that make use of its synchrotron facilities. The objective for the construction and operation of an office building is to provide adequate office space for existing SLAC Waste Management (WM) personnel, so as to centralize WM personnel and to make WM operations more efficient and effective. Based on the analyses in the EA, the DOE has determined that the proposed action does not constitute a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act of 1969 (NEPA). Therefore, the preparation of an Environmental Impact Statement is not required. This report contains the Environmental Assessment, as well as the Finding of No Significant Impact (FONSI)

  14. Operation of a novel two-pipe active beam system in an office building: a thermal comfort study

    DEFF Research Database (Denmark)

    Maccarini, Alessandro; Hultmark, Göran; Bergsøe, Niels Christian

    2018-01-01

    This paper presents an investigation regarding a thermal comfort study carried out in an office building located in Jönköping, Sweden. The particularity is that, in authors’ knowledge, this is the first building equipped with a novel active beam system that operates a water loop with temperatures...... for a continuous period of 24 hours. The daily monitoring of the thermal environment showed that the room air temperature was between approximately 21 °C and 23 °C all year round. No significant vertical air temperature difference was noticed, and the draught rate was below 10% for most of the cases....

  15. Final report of the radiological release survey of Building 11 at the Grand Junction Office Facility

    International Nuclear Information System (INIS)

    Johnson, R.K.; Corle, S.G.

    1997-09-01

    The U.S. Department of Energy (DOE) Grand Junction Office (GJO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore concentrates and mill tailings during vanadium refining activities of the Manhattan Engineer District, and during sampling, assaying, pilot milling, storage, and brokerage activities conducted for the U.S. Atomic Energy Commission's domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJO Remedial Action Project (GJORAP) to clean up and restore the facility lands, improvements, and underlying aquifer. WASTREN-Grand Junction is the site contractor for the facility and the remedial action contractor for GJORAP. Building 11 and the underlying soil were found not to be radiologically contaminated; therefore, the building can be released for unrestricted use. Placards have been placed at the building entrances indicating the completion of the radiological release survey and prohibiting the introduction of any radioactive materials within the building without written approvals from the GJO Facilities Operations Manager. This document was prepared in response to a DOE-GJO request for an individual final release report for each GJO building

  16. Final report of the radiological release survey of Building 29 at the Grand Junction Office Facility

    International Nuclear Information System (INIS)

    Johnson, R.K.; Corle, S.G.

    1997-09-01

    The U.S. Department of Energy (DOE) Grand Junction Office (GJO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore concentrates and mill tailing during vanadium refining activities of the Manhattan Engineer District, and during sampling, assaying, pilot milling, storage, and brokerage activities conducted for the U.S. Atomic Energy Commission's domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJO Remedial Action Project (GJORAP) to clean up and restore the facility lands, improvements, and underlying aquifer. WASTREN-Grand Junction is the site contractor for the facility and the remedial action contractor for GJORAP. Building 29 and the underlying soil were found not to be radiologically contaminated; therefore, the building can be released for unrestricted use. Placards have been placed at the building entrances indicating the completion of the radiological release survey and prohibiting the introduction of any radioactive materials within the building without written approvals from the GJO Facilities Operations Manager. This document was prepared in response to a DOE-GJO request for an individual final release report for each GJO building

  17. Final report of the radiological release survey of Building 19 at the Grand Junction Office Facility

    International Nuclear Information System (INIS)

    Johnson, R.K.; Corle, S.G.

    1997-09-01

    The U.S. Department of Energy (DOE) Grand Junction Office (GJO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore concentrates and mill tailings during vanadium refining activities of the Manhattan Engineer District, and during sampling, assaying, pilot milling, storage, and brokerage activities conducted for the U.S. Atomic Energy Commission's domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJO Remedial Action Project (GJORAP) to clean up and restore the facility lands, improvements, and underlying aquifer. WASTREN-Grand Junction is the site contractor for the facility and the remedial action contractor for GJORAP. Building 19 and the underlying soil were found not to be radiologically contaminated; therefore, the building can be released for unrestricted use. Placards have been placed at the building entrances indicating the completion of the radiological release survey and prohibiting the introduction of any radioactive materials within the building without written approvals from the GJO Facilities Operations Manager. This document was prepared in response to a DOE-GJO request for an individual final release report for each GJO building

  18. Building America House Performance Analysis Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Hendron, R.; Farrar-Nagy, S.; Anderson, R.; Judkoff, R.

    2001-10-29

    As the Building America Program has grown to include a large and diverse cross section of the home building industry, accurate and consistent analysis techniques have become more important to help all program partners as they perform design tradeoffs and calculate energy savings for prototype houses built as part of the program. This document illustrates some of the analysis concepts proven effective and reliable for analyzing the transient energy usage of advanced energy systems as well as entire houses. The analysis procedure described here provides a starting point for calculating energy savings of a prototype house relative to two base cases: builder standard practice and regional standard practice. Also provides building simulation analysis to calculate annual energy savings based on side-by-side short-term field testing of a prototype house.

  19. Cool roofs in China: Policy review, building simulations, and proof-of-concept experiments

    International Nuclear Information System (INIS)

    Gao, Yafeng; Xu, Jiangmin; Yang, Shichao; Tang, Xiaomin; Zhou, Quan; Ge, Jing; Xu, Tengfang; Levinson, Ronnen

    2014-01-01

    While the concept of reflective roofing is not new to China, most Chinese cool roof research has taken place within the past decade. Some national and local Chinese building energy efficiency standards credit or recommend, but do not require, cool roofs or walls. EnergyPlus simulations of standard-compliant Chinese office and residential building prototypes in seven Chinese cities (Harbin, Changchun, Beijing, Chongqing, Shanghai, Wuhan, and Guangzhou) showed that substituting an aged white roof (albedo 0.6) for an aged gray roof (albedo 0.2) yields positive annual load, energy, energy cost, CO 2 , NO x , and SO 2 savings in all hot-summer cities (Chongqing, Shanghai, Wuhan, and Guangzhou). Measurements in an office building in Chongqing in August 2012 found that a white coating lowered roof surface temperature by about 20 °C, and reduced daily air conditioning energy use by about 9%. Measurements in a naturally ventilated factory in Guangdong Province in August 2011 showed that a white coating decreased roof surface temperature by about 17 °C, lowered room air temperature by 1–3 °C, and reduced daily roof heat flux by 66%. Simulation and experimental results suggest that cool roofs should be credited or prescribed in building energy efficiency standards for both hot summer/warm winter and hot summer/cold winter climates in China

  20. Electricity use characteristics of purpose-built office buildings in subtropical climates

    International Nuclear Information System (INIS)

    Lam, Joseph C.; Chan, Ricky Y.C.; Tsang, C.L.; Li, Danny H.W.

    2004-01-01

    The electricity use characteristics of 20 air conditioned office buildings in the public sector in subtropical Hong Kong were investigated. Monthly electricity consumption data were gathered and analysed. The annual electricity use per unit gross floor area ranged from 163 to 389 kW h/m 2 , with a mean of 270 kW h/m 2 . Detailed energy audits and site surveys were conducted to obtain a breakdown of the energy use. The percentage consumption for the four major electricity end users, namely heating, ventilation and air conditioning, lighting, electrical equipment and lifts and escalators were 47.5%, 27.4%, 21.8% and 3.3%, respectively. Regression techniques were used to correlate the monthly electricity use with the design and climatic variables. This paper presents the work and discusses the energy use implications

  1. Energy and life-cycle cost analysis of a six-story office building

    Science.gov (United States)

    Turiel, I.

    1981-10-01

    An energy analysis computer program, DOE-2, was used to compute annual energy use for a typical office building as originally designed and with several energy conserving design modifications. The largest energy use reductions were obtained with the incorporation of daylighting techniques, the use of double pane windows, night temperature setback, and the reduction of artificial lighting levels. A life-cycle cost model was developed to assess the cost-effectiveness of the design modifications discussed. The model incorporates such features as inclusion of taxes, depreciation, and financing of conservation investments. The energy conserving strategies are ranked according to economic criteria such as net present benefit, discounted payback period, and benefit to cost ratio.

  2. Design methodology and criteria for daylight and thermal comfort in nearly-zero energy office buildings in Nordic climate

    DEFF Research Database (Denmark)

    Karlsen, Line Røseth

    The objective of this PhD thesis was to arrange for an integrated building design with respect to thermal comfort, daylighting and energy use, applicable for office buildings in Nordic climate. In order to achieve this, it is suggested that modelling of mean radiant temperature (MRT) should...... into the simulation tool IDA ICE. Furthermore, the control of solar shading is given attention, since it is a crucial link between the thermal and daylighting performance. The thesis presents results of an occupant survey with 46 subjects, which was carried out to investigate occupants’ preferences towards...

  3. Low-cost personal cooling in hot humid offices. Feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Gunnarsen, L [Danish Building Research Inst., (Denmark); Santos, A [Univ. of the Philippines, Diliman (Philippines)

    1997-05-01

    A solution, based on low-cost solar-powered air drying, to heat stress in buildings located in developing countries with a hot and humid climate is presented. The air-drying facilities are described and a validation of the ensuing benefits through comprehensive human exposure studies is given. A prototype of a solar powered supply system for dried air was constructed and supply air was led to six personal units for ventilation and cooling placed in cubicles simulating office workplaces. 123 heat-acclimatized people were exposed for one hour in each of the cubicles. It is concluded that drying indoor air reduces heat stress among heat-adapted people in hot and humid offices and that the low-cost solar powered air drying system functioned satisfactorily , although some improvements are recommended. The drying power of the sun can be stored in recovered silica gel beads and used for other purposes. It is suggested that further research could explore the possibility of desiccant drying of agricultural products during the rainy season. (ARW) 30 refs.

  4. Final report of the decontamination and decommissioning of Building 39 at the Grand Junction Projects Office Facility

    International Nuclear Information System (INIS)

    Widdop, M.R.

    1996-07-01

    The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission's domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJPO Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, is also the remedial action contractor. The soil beneath Building 39 was radiologically contaminated and the building was demolished in 1992. The soil area within the footprint of the building has been remediated in accordance with the identified standards and the area can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building

  5. ECCE Toolkit: Prototyping Sensor-Based Interaction

    Directory of Open Access Journals (Sweden)

    Andrea Bellucci

    2017-02-01

    Full Text Available Building and exploring physical user interfaces requires high technical skills and hours of specialized work. The behavior of multiple devices with heterogeneous input/output channels and connectivity has to be programmed in a context where not only the software interface matters, but also the hardware components are critical (e.g., sensors and actuators. Prototyping physical interaction is hindered by the challenges of: (1 programming interactions among physical sensors/actuators and digital interfaces; (2 implementing functionality for different platforms in different programming languages; and (3 building custom electronic-incorporated objects. We present ECCE (Entities, Components, Couplings and Ecosystems, a toolkit for non-programmers that copes with these issues by abstracting from low-level implementations, thus lowering the complexity of prototyping small-scale, sensor-based physical interfaces to support the design process. A user evaluation provides insights and use cases of the kind of applications that can be developed with the toolkit.

  6. Facilities improvement for sustainability of existing public office ...

    African Journals Online (AJOL)

    The study examined the building design features of a cosmopolitan public office building in Abuja. The features were classified into Spatial Plan, Structure and Facilities, to determine which of the 3 variables requires urgent sustainable improvement from end-users' perspective in existing public office buildings in developing ...

  7. Studies on switch-based event building systems in RD13

    International Nuclear Information System (INIS)

    Bee, C.P.; Eshghi, S.; Jones, R.

    1996-01-01

    One of the goals of the RD13 project at CERN is to investigate the feasibility of parallel event building system for detectors at the LHC. Studies were performed by building a prototype based on the HiPPI standard and by modeling this prototype and extended architectures with MODSIM II. The prototype used commercially available VME-HiPPI interfaces and a HiPPI switch together with a modular software. The setup was tested successfully as a parallel event building system in different configurations and with different data flow control schemes. The simulation program was used with realistic parameters from the prototype measurements to simulate large-scale event building systems. This includes simulations of a realistic setup of the ATLAS event building system. The influence of different parameters and scaling behavior were investigated. The influence of realistic event size distributions was checked with data from off-line simulations. Different control schemes for destination assignment and traffic shaping were investigated as well as a two-stage event building system. (author)

  8. A GUI Prototype for the Framework of Criminal Judicial Reasoning System

    OpenAIRE

    Thammaboosadee, Sotarat; Silparcha, Udom

    2009-01-01

    This paper proposed a developed graphical user interface (GUI) prototype, whichis supported by the framework of data mining techniques-based criminal judicial reasoning system.The GUI sequences of the prototype are satisfied with criminal judicial procedure in civil lawsystem. Initially, user must build the model by input the existing incident and specifying the detail ofobjects, elements of crime, charge and judgment. After enough training, the prototype will be readyto determine judgments f...

  9. Sick building syndrome (SBS) among office workers in a Malaysian university--Associations with atopy, fractional exhaled nitric oxide (FeNO) and the office environment.

    Science.gov (United States)

    Lim, Fang-Lee; Hashim, Zailina; Md Said, Salmiah; Than, Leslie Thian-Lung; Hashim, Jamal Hisham; Norbäck, Dan

    2015-12-01

    There are few studies on sick building syndrome (SBS) including clinical measurements for atopy and fractional exhaled nitric oxide (FeNO). Our aim was to study associations between SBS symptoms, selected personal factors, office characteristics and indoor office exposures among office workers from a university in Malaysia. Health data were collected by a questionnaire (n=695), skin prick test (SPT) (n=463) and FeNO test (n=460). Office settled dust was vacuumed and analyzed for endotoxin, (1,3)-β-glucan and house dust mites (HDM) allergens group 1 namely Dermatophagoides pteronyssinus (Der p 1) and Dermatophagoides farinae (Der f 1). Office indoor temperature, relative air humidity (RH), carbon monoxide (CO) and carbon dioxide (CO2) were measured by a direct reading instrument. Associations were studied by two-levels multiple logistic regression with mutual adjustment and stratified analysis. The prevalence of weekly dermal, mucosal and general symptoms was 11.9%, 16.0% and 23.0% respectively. A combination of SPT positivity (allergy to HDM or cat) and high FeNO level (≥25 ppb) was associated with dermal (p=0.002), mucosal (p<0.001) and general symptoms (p=0.05). Der f1 level in dust was associated with dermal (p<0.001), mucosal (p<0.001) and general (p=0.02) symptoms. Among those with allergy to D. farinae, associations were found between Der f 1 levels in dust and dermal (p=0.003), mucosal (p=0.001) and general symptoms (p=0.007). Office-related symptoms were associated with Der f 1 levels in dust (p=0.02), low relative air humidity (p=0.04) and high office temperature (p=0.05). In conclusion, a combination of allergy to cat or HDM and high FeNO is a risk factor for SBS symptoms. Der f 1 allergen in dust can be a risk factor for SBS in the office environment, particularly among those sensitized to Der f 1 allergen. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Eawag Forum Chriesbach - Simulation and measurement of energy performance and comfort in a sustainable office building

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, B.; Dorer, V.; Frank, Th. [Empa, Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Building Science and Technology, Ueberlandstrasse 129, CH-8600 Duebendorf (Switzerland); Guettinger, H. [Eawag, Swiss Federal Institute of Aquatic Science and Technology, Duebendorf (Switzerland); van Velsen, S.; Thiemann, A. [3-Plan Haustechnik AG, Winterthur (Switzerland)

    2010-10-15

    The Eawag's new headquarters ''Forum Chriesbach'' is an exemplary illustration of a 'sustainable' construction design for office buildings. With a unique combination of architectural and technical elements the building reaches a very low 88 kWh/m{sup 2} overall primary energy consumption, which is significantly lower than the Swiss Passive House standard, Minergie-P. A monitoring and evaluation project shows that the building is heated mainly by using the sun and internal heat gains from lighting, electrical appliances and occupants, resulting in an extremely low space heating demand. Cooling is provided by natural night time ventilation and the earth-coupled air intake, which pre-cools supply air and provides free cooling for computer servers. However, values for embodied energy and electricity consumption remain significant, even with partial on-site electricity production using photovoltaics. TRNSYS computer simulations show the contributions of individual building services to the overall energy balance and indicate that the building is resilient towards changes in parameters such as climate or occupancy density. Measurements confirm comfortable room temperatures below 26 C, even during an extremely hot summer period, and 20-23 C in the winter season. An economic analysis reveals additional costs of only 5% compared to a conventionally constructed building and a payback-time of 13 years. (author)

  11. Simulation Study of Performance of Active Ceilings with Phase Change Material in Office Buildings under Extreme Climate Conditions

    DEFF Research Database (Denmark)

    Stefansen, Casper; Farhan, Hajan; Bourdakis, Eleftherios

    2018-01-01

    simulations were run with a building simulation software for eight climates. The chosen climates were Dubai –UAE, Istanbul – Turkey, Lima – Peru, Moscow – Russia, Nuuk – Greenland, Salvador – Brazil, Tokyo – Japan and Tromsø – Norway. Two models of a two-person office were made for each climate; one model...

  12. Air movement, gender and risk of sick building headache among employees in a Jakarta office

    Directory of Open Access Journals (Sweden)

    Margaretha Winarti

    2003-09-01

    Full Text Available Even though office buildings are usually equipped with ventilation system or air conditioning to create a comfortable working environment, yet there is still found a number of sick building syndrome (SBS symptoms. One of the symptoms of SBS is SBS headache. Therefore, it is crucial to identify risk factors related to SBS headache. Cases were subjects who have suffered SBS headache, and controls were subjects who did not suffered headache for the last one month. Cases and controls were selected through a survey on all of employees in the said office during the period of May to August 2002. Total respondents were 240 employees including 36 people suffered SBS headache (15%. Compared to the normal air movement, faster air movement decreased the risk of SBS headache by 57% [adjusted odds ratio (OR = 0.43; 95% confidence intervals (CI: 0.19-0.95]. Female employees, compared to the males ones, had a higher risk of getting SBS headache by almost three times (adjusted OR = 2.96: 95% CI: 1.29-6.75. Employees who had breakfast irregularly, had a lower risk to SBS headache than those who have breakfast regularly (adjusted OR=0.31; 95% CI: 0.09-0.84. Temperature, humidity and smoking habits were not noted correlated to SBS headache. Female workers had greater risk of suffering SBS headache. In addition slower air movement increased the risk of SBS headache. Therefore, it is recommended to improve the progress of air in order to reduce the risk of SBS headache, especially for female workplace. (Med J Indones 2003; 12: 171-7Keywords: sick building syndrome headache, gender, air movement

  13. Report on detailed requirements for the INFLO prototype.

    Science.gov (United States)

    2013-12-01

    This report documents the System Requirements for the implementation of the Intelligent Network Flow Optimization (INFLO) : Prototype bundle within the Dynamic Mobility Applications (DMA) portion of the Connected Vehicle Program. It builds off of : t...

  14. The physical environment and occupant thermal perceptions in office buildings. An evaluation of sampled data from five European countries

    Energy Technology Data Exchange (ETDEWEB)

    Stoops, J L [Chalmers Univ. of Tech., Goeteborg (Sweden). Dept. of Building Services Engineering

    2002-02-01

    The results from a large field study of thermal comfort in European office buildings are reported. Measurements of physical environmental conditions and occupant perceptions were collected over sixteen months from twenty-six different office buildings located in France, Greece, Portugal, Sweden and the UK. This thesis focuses on the physical environmental measurements and occupant thermal perceptions; however, additional variables with connections to environmental satisfaction are also examined. An overview of human comfort theory is presented to help place this thesis in appropriate context. The overview presents thermal comfort issues within a broad framework of human response to the environment including physical, physiological. behavioural, psychological and other variables. A more narrowly focused overview of current thermal comfort research is also included. The work attempts to show relationships and produce useful information from the data set using graphical methods, especially lowess, a locally weighted regression based scatter plot smoothing technique. The objective of using this approach is to literally show the relationships visually. This approach allows the data set itself to illustrate the actual thermal conditions in European office buildings and the occupant perceptions of those conditions along with illustrating relationships. The data is examined in some detail with key relationships identified and explored. Significant differences between countries, both for the physical conditions and the perceptions of those conditions are identified. In addition, the variation over the course of the year for each country is explored. The relationship of daily average outdoor temperatures to indoor temperatures and indoor temperature perceptions is found to be critically important. The relationships, which appear to drive perceptions of thermal comfort, occur in complex ways, making simple, all encompassing explanations impossible. The nature and size of the

  15. Highlighting High Performance: National Renewable Energy Laboratory's Thermal Test Facility, Golden, Colorado. Office of Building Technology State and Community Programs (BTS) Brochure

    International Nuclear Information System (INIS)

    Burgert, S.

    2001-01-01

    The National Renewable Energy Laboratory's Thermal Test Facility in Golden, Colorado, was designed using a whole-building approach-looking at the way the building's systems worked together most efficiently. Researchers monitor the performance of the 11,000-square-foot building, which boasts an energy cost savings of 63% for heating, cooling, and lighting. The basic plan of the building can be adapted to many needs, including retail and warehouse space. The Thermal Test Facility contains office and laboratory space; research focuses on the development of energy-efficiency and renewable energy technologies that are cost-effective and environmentally friendly

  16. A Retrofit Tool for Improving Energy Efficiency of Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Levine, Mark; Feng, Wei; Ke, Jing; Hong, Tianzhen; Zhou, Nan

    2013-06-06

    Existing buildings will dominate energy use in commercial buildings in the United States for three decades or longer and even in China for the about two decades. Retrofitting these buildings to improve energy efficiency and reduce energy use is thus critical to achieving the target of reducing energy use in the buildings sector. However there are few evaluation tools that can quickly identify and evaluate energy savings and cost effectiveness of energy conservation measures (ECMs) for retrofits, especially for buildings in China. This paper discusses methods used to develop such a tool and demonstrates an application of the tool for a retrofit analysis. The tool builds on a building performance database with pre-calculated energy consumption of ECMs for selected commercial prototype buildings using the EnergyPlus program. The tool allows users to evaluate individual ECMs or a package of ECMs. It covers building envelope, lighting and daylighting, HVAC, plug loads, service hot water, and renewable energy. The prototype building can be customized to represent an actual building with some limitations. Energy consumption from utility bills can be entered into the tool to compare and calibrate the energy use of the prototype building. The tool currently can evaluate energy savings and payback of ECMs for shopping malls in China. We have used the tool to assess energy and cost savings for retrofit of the prototype shopping mall in Shanghai. Future work on the tool will simplify its use and expand it to cover other commercial building types and other countries.

  17. Final report of the radiological release survey of Building 30B at the Grand Junction Office Facility

    International Nuclear Information System (INIS)

    Krauland, P.A.; Corle, S.G.

    1997-09-01

    The U.S. Department of Energy (DOE) Grand Junction Office (GJO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore concentrates and mill tailings during vanadium refining activities of the Manhattan Engineer District, and during sampling, assaying, pilot milling, storage, and brokerage activities conducted for the U.S. Atomic Energy Commission's domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJO Remedial Action Project (GJORAP) to clean up and restore the facility lands, improvements, and underlying aquifer. WASTREN-Grand Junction is the site contractor for the facility and the remedial action contractor for GJORAP. Building 30B and the underlying soil were found not to be radiologically contaminated; therefore, the building can be released for unrestricted use. Placards have been placed at the building entrances indicating the completion of the radiological release survey and prohibiting the introduction of any radioactive materials within the building without written approvals from the GJO Facilities Operations Manager. This document was prepared in response to a DOE-GJO request for an individual final release report for each GJO building

  18. Final report of the radiological release survey of Building 54 at the Grand Junction Office Facility

    International Nuclear Information System (INIS)

    Johnson, R.K.; Corle, S.G.

    1997-09-01

    The U.S. Department of Energy (DOE) Grand Junction Office (GJO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore concentrates and mill tailings during vanadium refining activities of the Manhattan Engineer District, and during sampling, assaying, pilot milling, storage, and brokerage activities conducted for the U.S. Atomic Energy Commission's domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJO Remedial Action Project (GJORAP) to clean up and restore the facility lands, improvements, and underlying aquifer. WASTREN-Grand Junction is the site contractor for the facility and the remedial action contractor for GJORAP. Building 54 and the underlying soil were found not to be radiologically contaminated, and can be released for unrestricted use. Placards have been placed at the building entrances indicating the completion of the radiological release survey and prohibiting the introduction of any radioactive materials within the building without written approvals from the GJO Facilities Operations Manager. This document was prepared in response to a DOE-GJO request for an individual release report for each GJO building

  19. Utilizing Rapid Prototyping for Architectural Modeling

    Science.gov (United States)

    Kirton, E. F.; Lavoie, S. D.

    2006-01-01

    This paper will discuss our approach to, success with and future direction in rapid prototyping for architectural modeling. The premise that this emerging technology has broad and exciting applications in the building design and construction industry will be supported by visual and physical evidence. This evidence will be presented in the form of…

  20. Utilization of virtual prototyping in development of CMM

    International Nuclear Information System (INIS)

    Raneda, A.; Pessi, P.; Siuko, M.; Handroos, H.; Palmer, J.; Vilenius, M.

    2003-01-01

    The characteristic advantages of hydraulics (high power density, simple construction and reliability) together with the characteristics of water as the pressure medium (fire and environmentally safe, chemically neutral, not activated nor affected by radiation) are highlighted in critical applications such as remote handling operations in International Thermonuclear Experimental Reactor (ITER). However, component cost and lack of wide selection of water hydraulic components make it difficult to build and to test complex water hydraulic systems. The use of virtual prototyping for the development of water hydraulic tools can be used to address this problem. Rapidly increased computational power has created conditions for extensive numerical calculations, enabling computer aided virtual prototyping to replace physical prototype phases in product development

  1. The role of corporate reputation and employees' values in the uptake of energy efficiency in office buildings

    International Nuclear Information System (INIS)

    Pellegrini-Masini, Giuseppe; Leishman, Chris

    2011-01-01

    Although office market actors in the United Kingdom show a growing interest in energy efficiency, the pace of takeup of energy efficient office features is slow. Previous studies have highlighted the roles of limited direct financial costs and benefits ('efficiency gaps') and market barriers in limiting the rate of technology adoption. This study provides further evidence on the importance of these factors, but the primary contribution is focused on the role of corporate reputation and on the importance of individuals' values in shaping corporate behaviour. The paper presents a theoretical framework to explain environmental decision making in firms and we present qualitative evidence drawing from sixteen semi-structured individual and group interviews with office market stakeholders in London, Glasgow and Edinburgh. The research finds that companies, despite gradually becoming more energy conscious, still regard energy costs as a negligible part of their business costs. Nevertheless, an increasingly important driver is the reputational gain obtained by corporate businesses implementing sustainable practices. All the interviewees agreed that the pace of change in the office market is slow and that only further policy interventions will accelerate it. - Highlights: → Corporate reputation leads large businesses to seek energy efficient offices. → Investors show growing interest in green offices because of CSR and investment value. → Energy efficiency is not yet a top priority attribute in building choice. → Stakeholders believe that regulation is needed to accelerate the pace of change.

  2. PCM-air heat exchangers for free-cooling applications in buildings: Experimental results of two real-scale prototypes

    International Nuclear Information System (INIS)

    Lazaro, Ana; Dolado, Pablo; Marin, Jose M.; Zalba, Belen

    2009-01-01

    Latent heat storage using phase change materials (PCM) can be used for free-cooling. In this application low air temperature is used to solidify the PCM during the night and then during the next day, the inside air of a building can be cooled down by exchanging heat with PCM. Short times for charging and discharging the PCM are required. PCM have in general low thermal conductivity, therefore the heat exchanger design is very important to fulfil free-cooling requirements. This paper presents an experimental setup for testing PCM-air real-scale heat exchangers and the results for two real-scale prototypes. Results show that a heat exchanger using a PCM with lower thermal conductivity and lower total stored energy, but adequately designed, has higher cooling power and can be applied for free-cooling

  3. Final report of the decontamination and decommissioning of Building 6 at the Grand Junction Projects Office Facility

    International Nuclear Information System (INIS)

    Widdop, M.R.

    1996-07-01

    The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the domestic uranium procurement program funded by the U.S. Atomic Energy Commission. The DOE Defense Decontamination and Decommissioning Program established the GJPO Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, is also the remedial action contractor. Radiological contamination was identified in Building 6, and the building was demolished in 1992. The soil area within the footprint of the building has been remediated in accordance with the identified standards and the area can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building

  4. Rapid prototyping of complete systems, the case study of a smart parking

    OpenAIRE

    Ducreux , Laurent-Frédéric; Guyon-Gardeux , Claire; Louvel , Maxime; Pacull , François; Safietou Raby , Thior; Vergara-Gallego , Maria Isabel

    2015-01-01

    International audience; This paper details how LINC a coordination middle-ware, can fasten the development of prototypes that integrate several equipment. A case study of rapid prototyping is presented. It illustrates how a smart parking prototype has been built from several independent and autonomous equipment, coming from different vendors. This has been achieved by parallel development thanks to the resource based approach offered by LINC. This paper also describes how LINC helps building ...

  5. Prototyping the PANDA Barrel DIRC

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, C., E-mail: C.Schwarz@gsi.de [GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt (Germany); Kalicy, G.; Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Hohler, R.; Kumawat, H.; Lehmann, D.; Lewandowski, B.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwiening, J.; Traxler, M.; Zühlsdorf, M. [GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt (Germany); Dodokhov, V.Kh. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Britting, A.; Eyrich, W.; Lehmann, A. [Friedrich Alexander-University of Erlangen-Nuremberg, Erlangen (Germany); and others

    2014-12-01

    The design of the Barrel DIRC detector for the future PANDA experiment at FAIR contains several important improvements compared to the successful BABAR DIRC, such as focusing and fast timing. To test those improvements as well as other design options a prototype was build and successfully tested in 2012 with particle beams at CERN. The prototype comprises a radiator bar, focusing lens, mirror, and a prism shaped expansion volume made of synthetic fused silica. An array of micro-channel plate photomultiplier tubes measures the location and arrival time of the Cherenkov photons with sub-nanosecond resolution. The development of a fast reconstruction algorithm allowed to tune construction details of the detector setup with test beam data and Monte-Carlo simulations.

  6. Energy efficiency of new school buildings and office buildings in Luxembourg based on consumption data and simulations; Energieeffizienz neuer Schul- und Buerogebaeude in Luxemburg basierend auf Verbrauchsdaten und Simulationen

    Energy Technology Data Exchange (ETDEWEB)

    Thewes, Andreas

    2011-07-01

    energy-relevant parameters such as daylight-controlled lighting or the use of passive night ventilation concepts with existing buildings using measurement techniques. As conclusion, the central-European climate zone provides sufficient opportunities to design energy-saving office and school buildings (primary energy consumption < 100 kWh/m{sup 2}a) without mechanical cooling and ventilation systems that still guarantee appropriate degrees of thermal comfort. However, this means there must be no errors within the planning phase of the building design and the users of the building must have sufficient understanding of all required measures. Unfortunately, the real average primary energy consumption figures of new school (187 kWh/m{sup 2}a) and office buildings (677 kWh/m{sup 2}a) in Luxemburg are still significantly higher. (orig.)

  7. Higher energy efficiency in administrative and office buildings. Optimisation of primary energy consumption and economic efficiency; Energieeffiziente Buero- und Verwaltungsgebaeude. Hinweise zur primaerenergetischen und wirtschaftlichen Optimierung

    Energy Technology Data Exchange (ETDEWEB)

    Knissel, J.

    1999-12-15

    The study investigates measures to reduce primary energy consumption in administrative and office buildings and their effects in terms of economic efficiency. An exemplary office building is modernised step by step while recording the changes in the primary energy consumption coefficient. [German] In der vorliegenden Studie wird untersucht, wie weit und mit welchen Massnahmen der Primaerenergiebedarf von Buero- und Verwaltungsgebaeuden gesenkt werden kann und welche Auswirkungen dies auf die Wirtschaftlichkeit hat. Hierzu wird die energetische Ausfuehrungsqualitaet eines einfachen Beispielgebaeudes schrittweise verbessert und die Veraenderung des Primaerenergiekennwertes ermittelt. (orig.)

  8. Eurotheum Frankfurt/Main. New office and apartment building for cosmopolites; Eurotheum Frankfurt/Main. Buero- und Wohnhochhaus fuer Kosmopoliten

    Energy Technology Data Exchange (ETDEWEB)

    Pielke, O.E.

    2000-07-01

    The Eurotheum in Frankfurt is Germany's first and only high-rise building which houses both offices and private apartments. [German] Das Eurotheum stellt im Spannungsfeld der Frankfurter Buerohochhaeuser ein voellig neues Konzept dar: Es ist das erste und bisher einzige Hochhaus in Deutschland, in dem die Funktionen 'Arbeiten' und 'Wohnen' in einem Hochhaus verbunden werden. (orig.)

  9. Prototype Systems for Measuring Outdoor Air Intake Rates in Rooftop Air Handlers

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Chan, Wanyu R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hotchi, Toshifumi [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-01-01

    The widespread absence of systems for real-time measurement and feedback control, of minimum outdoor air intake rates in HVAC systems contributes to the poor control of ventilation rates in commercial buildings. Ventilation rates affect building energy consumption and influence occupant health. The project designed fabricated and tested four prototypes of systems for measuring rates of outdoor air intake into roof top air handlers. All prototypes met the ±20% accuracy target at low wind speeds, with all prototypes accurate within approximately ±10% after application of calibration equations. One prototype met the accuracy target without a calibration. With two of four prototype measurement systems, there was no evidence that wind speed or direction affected accuracy; however, winds speeds were generally below usually 3.5 m s-1 (12.6 km h-1) and further testing is desirable. The airflow resistance of the prototypes was generally less than 35 Pa at maximum RTU air flow rates. A pressure drop of this magnitude will increase fan energy consumption by approximately 4%. The project did not have resources necessary to estimate costs of mass produced systems. The retail cost of components and materials used to construct prototypes ranged from approximately $1,200 to $1,700. The test data indicate that the basic designs developed in this project, particularly the designs of two of the prototypes, have considerable merit. Further design refinement, testing, and cost analysis would be necessary to fully assess commercial potential. The designs and test results will be communicated to the HVAC manufacturing community.

  10. Building-related symptoms among U.S. office workers and risks factors for moisture and contamination: Preliminary analyses of U.S. EPA BASE Data

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, Mark J.; Cozen, Myrna

    2002-09-01

    The authors assessed relationships between health symptoms in office workers and risk factors related to moisture and contamination, using data collected from a representative sample of U.S. office buildings in the U.S. EPA BASE study. Methods: Analyses assessed associations between three types of weekly, workrelated symptoms-lower respiratory, mucous membrane, and neurologic-and risk factors for moisture or contamination in these office buildings. Multivariate logistic regression models were used to estimate the strength of associations for these risk factors as odds ratios (ORs) adjusted for personal-level potential confounding variables related to demographics, health, job, and workspace. A number of risk factors were associated (e.g., 95% confidence limits excluded 1.0) significantly with small to moderate increases in one or more symptom outcomes. Significantly elevated ORs for mucous membrane symptoms were associated with the following risk factors: presence of humidification system in good condition versus none (OR = 1.4); air handler inspection annually versus daily (OR = 1.6); current water damage in the building (OR = 1.2); and less than daily vacuuming in study space (OR = 1.2). Significantly elevated ORs for lower respiratory symptoms were associated with: air handler inspection annually versus daily (OR = 2.0); air handler inspection less than daily but at least semi-annually (OR=1.6); less than daily cleaning of offices (1.7); and less than daily vacuuming of the study space (OR = 1.4). Only two statistically significant risk factors for neurologic symptoms were identified: presence of any humidification system versus none (OR = 1.3); and less than daily vacuuming of the study space (OR = 1.3). Dirty cooling coils, dirty or poorly draining drain pans, and standing water near outdoor air intakes, evaluated by inspection, were not identified as risk factors in these analyses, despite predictions based on previous findings elsewhere, except that very

  11. The STEP standard as an approach for design and prototyping

    OpenAIRE

    Plantec , Alain; Ribaud , Vincent

    1998-01-01

    International audience; STEP is an ISO standard (ISO-10303) for the computer-interpretable representation and exchange of product data. Parts of STEP standardize conceptual structures and usage of information in generic or specific domains. The standardization process of these constructs is an evolutionary approach , which uses generated prototypes at different phases of the process. This paper presents a method for the building of prototype generators, inspired by this standardization proces...

  12. Building for the future: The Eurotheum at Frankfurt, Main - an office and domestic building for cosmopolites; Gebaeudetechnische Konzepte der Zukunft: Buero- und Wohnhochhaus fuer Kosmopoliten - Das Eurotheum in Frankfurt am Main

    Energy Technology Data Exchange (ETDEWEB)

    Pielke, O.E. [Brendel Ingenieure AG, Frankfurt am Main (Germany)

    2002-09-01

    The 'Eurotheum' building in Frankfurt is the first high-rise building in Germany that houses both offices and private apartments. It received the 'Immobilien Award 1999 - Cimmit' for industrial buildings by Immobilien-Zeitung and the Institute for International Research of Projektentwicklungsgesellschaft Koellmann AG. [German] Das Eurotheum im Spannungsfeld der Frankfurter Buerohochhaeuser beruht auf einem voellig neuen Konzept: Es verbindet als erstes Hochaus in Deutschland die Funktionen 'Arbeiten' und 'Wohnen'. Fuer das bislang einmalige Konzept des Frankfurter Eurotheums verlieh die Immobilien-Zeitung und das Institute for International Research der Projektentwicklungsgesellschaft Koellmann AG den Immobilien Award 1999 - Cimmit in der Kategorie Gewerbeimmobilien. (orig.)

  13. Incidence of polybrominated diphenyl ethers in central air conditioner filter dust from a new office building.

    Science.gov (United States)

    Ni, Hong-Gang; Cao, Shan-Ping; Chang, Wen-Jing; Zeng, Hui

    2011-07-01

    This study examined polybrominated diphenyl ethers (PBDEs) in central air conditioner filter (CACF) dust from a new office building in Shenzhen, China. Human exposure to PBDE via dust inhalation and ingestion were also estimated. PBDEs level in CACF dust was lower than those in the other countries and regions. Approximately 0.671 pg/kg bw/day PM(2.5) (Particulate Matter up to 2.5 μm in size) bounded Σ(15)PBDEs can be inhaled deep into the lungs and 4.123 pg/kg bw/day PM(10) (Particulate Matter up to 10 μm in size) bounded Σ(15)PBDEs tend to be deposited in the upper parts of the respiratory system. The average total intake of Σ(15)PBDEs via dust inhalation and ingestion for adults reached ∼ 141 pg/kg bw/day in this building. This value was far below the reference dose (RfD) recommended by United States Environmental Protection Agency. Human exposure to PBDEs via dust inhalation and ingestion in the new building is less than the old ones. Copyright © 2010 Elsevier Ltd. All rights reserved.

  14. Influence of Courtyard Ventilation on Thermal Performance of Office Building in Hot-Humid Climate: A Case Study

    Science.gov (United States)

    Abbaas, Esra'a. Sh.; Saif, Ala'eddin A.; Munaaim, MAC; Azree Othuman Mydin, Md.

    2018-03-01

    The influence of courtyard on the thermal performance of Development Department office building in University Malaysia Perlis (UniMAP, Pauh Putra campus) is investigated through simulation study for the effect of ventilation on indoor air temperature and relative humidity of the building. The study is carried out using EnergyPlus simulator interface within OpenStudio and SketchUp plug in software to measure both of air temperature and relative humidity hourly on 21 April 2017 as a design day. The results show that the ventilation through the windows facing the courtyard has sufficient effect on reducing the air temperature compared to the ventilation through external windows since natural ventilation is highly effective on driving the indoor warm air out to courtyard. In addition, the relative humidity is reduced due to ventilation since the courtyard has high ability to remove or dilute indoor airborne pollutants coming from indoor sources. This indicates that the presence of courtyard is highly influential on thermal performance of the building.

  15. Final report of the decontamination and decommissioning of Building 1 at the Grand Junction Projects Office Facility

    International Nuclear Information System (INIS)

    Widdop, M.R.

    1996-08-01

    The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission's domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJPO Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, also is the remedial action contractor. Building 1 was found to be radiologically contaminated and was demolished in 1996. The soil beneath and adjacent to the building was remediated in accordance with identified standards and can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building

  16. Gamma-ray and neutron area monitoring system of linear IFMIF prototype accelerator building

    International Nuclear Information System (INIS)

    Takahashi, Hiroki; Kojima, Toshiyuki; Narita, Takahiro; Tsutsumi, Kazuyoshi; Maebara, Sunao; Sakaki, Hironao; Nishiyama, Koichi

    2013-01-01

    Highlights: • Area monitoring system and control system are needed for LIPAc radiation management. • To secure the radiation safety, these systems are linked with two kinds of data path. • Hardwired data paths are adopted to realize the fast transfer of interlock signals. • Dual LAN and shared memory are adopted to the reliable transfer of monitoring data. • Data transfers without unnecessary load are designed and configured for these systems. -- Abstract: The linear IFMIF prototype accelerator (LIPAc) produces deuteron beam with 1 MW power. Since huge number of neutrons occur from such a high power beam, therefore, it is important for the radiation management to design a high reliability area monitoring system for gamma-rays and neutrons. To obtain the valuable operation data of the high-power deuteron beam at LIPAc, it is important to link and record the beam operation data and the area monitoring data. We realize the reliable data transfer to provide the area monitoring data to the accelerator control system which needs a high reliability using the shared-memory data link method. This paper describes the area monitoring system in the LIPAc building and the data-link between this system and the LIPAc control system

  17. Indoor climate, psychosocial work environment and symptoms in open-plan offices

    DEFF Research Database (Denmark)

    Pejtersen, J; Allermann, L; Kristensen, T S

    2006-01-01

    To study the indoor climate, the psychosocial work environment and occupants' symptoms in offices a cross-sectional questionnaire survey was made in 11 naturally and 11 mechanically ventilated office buildings. Nine of the buildings had mainly cellular offices; five of the buildings had mainly open...... irritation, skin irritation, central nervous system (CNS) symptoms and psychosocial factors. Occupants in open-plan offices are more likely to perceive thermal discomfort, poor air quality and noise and they more frequently complain about CNS and mucous membrane symptoms than occupants in multi......-person and cellular offices. The association between psychosocial factors and office size was weak. Open-plan offices may not be suited for all job types. PRACTICAL IMPLICATION: Open-plan offices may be a risk factor for adverse environmental perceptions and symptoms....

  18. Risk Factors in Heating, Ventilating, and Air-Conditioning Systemsfor Occupant Symptoms in U.S. Office Buildings: the EPA BASE Study

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, M.J.; Lei-Gomez, Q.; Mirer, A.; Seppanen, O.; Brunner, G.

    2006-10-01

    Nonspecific building-related symptoms among occupants of modern office buildings worldwide are common and may be associated with important reductions in work performance, but their etiology remains uncertain. Characteristics of heating, ventilating, and air-conditioning (HVAC) systems in office buildings that increase risk of indoor contaminants or reduce effectiveness of ventilation may cause adverse exposures and subsequent increase in these symptoms among occupants. We analyzed data collected by the U.S. EPA from a representative sample of 100 large U.S. office buildings--the Building Assessment and Survey Evaluation (BASE) study--using multivariate logistic regression models with generalized estimating equations adjusted for potential personal and building confounders. We estimated odds ratios (ORs) and 95% confidence intervals (CIs) for associations between seven building-related symptom outcomes and selected HVAC system characteristics. Among factors of HVAC design or configuration: Outdoor air intakes less than 60 m above the ground were associated with approximately doubled odds of most symptoms assessed. Sealed (non-operable) windows were associated with increases in skin and eye symptoms (ORs= 1.9, 1.3, respectively). Outdoor air intake without an intake fan was associated with an increase in eye symptoms (OR=1.7). Local cooling coils were associated with increased headache (OR=1.5). Among factors of HVAC condition, maintenance, or operation: the presence of humidification systems in good condition was associated with an increase in headache (OR=1.4), whereas the presence of humidification systems in poor condition was associated with increases in fatigue/difficulty concentrating, as well as upper respiratory symptoms (ORs=1.8, 1.5). No regularly scheduled inspections for HVAC components was associated with increased eye symptoms, cough and upper respiratory symptoms (ORs=2.2, 1.6, 1.5). Less frequent cleaning of cooling coils or drip pans was associated

  19. Characteristics of radon and its progeny concentrations in air-conditioned office buildings in Tokyo

    International Nuclear Information System (INIS)

    Tokonami, S.; Furukawa, M.; Shicchi, Y.; Sanada, T.; Yamada, Y.

    2003-01-01

    A series of measurements were carried out to understand the characteristics of radon and its progeny in air-conditioned office buildings. Long-term measurements of radon were made with etched track detectors. Continuous measurements of radon and its progeny concentrations were also conducted in some buildings to study their temporal variations. The results show that radon and its progeny concentrations routinely varied along with working activities. They are generally low while people are working, due to air conditioning, whereas they rise steadily after the air conditioning stops. When considering action levels not only in homes but also workplaces, attention should be paid to annual doses from the viewpoint of radiation protection. The annual dose is generally estimated with a long-term measurement of radon concentration using a passive device such as an etched track detector. Since its reading corresponds to a long-term average concentration regardless of working hours, the annual dose will be overestimated. When comparing a real dose after considering the working hours, they differ by a factor of more than 2. (author)

  20. Biological dynamic lighting in an office building; Biologisch dynamische verlichting in een kantoorgebouw

    Energy Technology Data Exchange (ETDEWEB)

    Visser, R. [Professional Lighting Designers' Association PLDA, Guetersloh (Germany)

    2011-12-15

    The aim of so-called biodynamic lighting systems is to influence human biological rhythms such that productivity, alertness, wellbeing and health are improved. In the office building of Grontmij in Amersfoort, Netherlands, experiments were carried out with biodynamic lighting systems. [Dutch] In de afgelopen jaren hebben verschillende fabrikanten biologisch dynamische verlichtingssystemen op de markt gebracht. Uitgangspunt voor dergelijke systemen is om biologische ritmen van de mens zodanig te beinvloeden dat productiviteit, alertheid, welbevinden en ook de gezondheid in meer of mindere mate verbeteren. Om ervaring in de kantooromgeving op te doen, is een aantal van deze systemen op diverse locaties in het gebouw van de Grontmij in Amersfoort aangebracht. Vervolgens is onderzoek gedaan naar de toepassingsmogelijkheden en eigenschappen ervan in de praktijk.

  1. The role of corporate reputation and employees' values in the uptake of energy efficiency in office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Pellegrini-Masini, Giuseppe, E-mail: gp89@hw.ac.uk [School of the Built Environment, Chadwick Building, Heriot-Watt University, Riccarton, EH14 4AS Edinburgh (United Kingdom); Leishman, Chris, E-mail: chris.leishman@glasgow.ac.uk [School of Social and Political Sciences, University of Glasgow, 25 Bute Gardens, G12 8RS Glasgow (United Kingdom)

    2011-09-15

    Although office market actors in the United Kingdom show a growing interest in energy efficiency, the pace of takeup of energy efficient office features is slow. Previous studies have highlighted the roles of limited direct financial costs and benefits ('efficiency gaps') and market barriers in limiting the rate of technology adoption. This study provides further evidence on the importance of these factors, but the primary contribution is focused on the role of corporate reputation and on the importance of individuals' values in shaping corporate behaviour. The paper presents a theoretical framework to explain environmental decision making in firms and we present qualitative evidence drawing from sixteen semi-structured individual and group interviews with office market stakeholders in London, Glasgow and Edinburgh. The research finds that companies, despite gradually becoming more energy conscious, still regard energy costs as a negligible part of their business costs. Nevertheless, an increasingly important driver is the reputational gain obtained by corporate businesses implementing sustainable practices. All the interviewees agreed that the pace of change in the office market is slow and that only further policy interventions will accelerate it. - Highlights: > Corporate reputation leads large businesses to seek energy efficient offices. > Investors show growing interest in green offices because of CSR and investment value. > Energy efficiency is not yet a top priority attribute in building choice. > Stakeholders believe that regulation is needed to accelerate the pace of change.

  2. Final report of the decontamination and decommission of Building 31 at the Grand Junction Projects Office Facility

    International Nuclear Information System (INIS)

    Krabacher, J.E.

    1996-07-01

    The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the domestic uranium procurement program funded by the U.S. Atomic Energy Commission. The DOE Defense Decontamination and Decommissioning Program established the GJPO Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, also was the remedial action contractor. Radiological contamination was identified in Building 31 and the building was demolished in 1992. The soil area within the footprint of the building has been remediated in accordance with the identified standards and the area can be released for unlimited exposure and unrestricted use. This area was addressed in the summary final report of the remediation of the exterior areas of the GJPO facility. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building

  3. Solar heating and hot water system installed at office building, One Solar Place, Dallas, Texas

    Science.gov (United States)

    1980-01-01

    A solar heating on cooling system is described which is designed to provide 87 percent of the space heating needs, 100 percent of the potable hot water needs and is sized for future absorption cooling. The collection subsystem consists of 28 solargenics, series 76, flat plate collectors with a total area of 1,596 square feet. The solar loop circulates an ethylene glyco water solution through the collectors into a hot water system exchanger. The water storage subsystem consists of a heat exchanger, two 2,300 gallon concrete hot water storage tanks with built in heat exchangers and a back-up electric boiler. The domestic hot water subsystem sends hot water to the 10,200 square feet floor area office building hot water water fixtures. The building cold water system provides make up to the solar loop, the heating loop, and the hot water concrete storage tanks. The design, construction, cost analysis, operation and maintenance of the solar system are described.

  4. Co-simulation of innovative integrated HVAC systems in buildings

    Energy Technology Data Exchange (ETDEWEB)

    Trcka, Marija; Hensena, Jan L.M.; Wetter, Michael

    2010-06-21

    Integrated performance simulation of buildings HVAC systems can help in reducing energy consumption and increasing occupant comfort. However, no single building performance simulation (BPS) tool offers sufficient capabilities and flexibilities to analyze integrated building systems and to enable rapid prototyping of innovative building and system technologies. One way to alleviate this problem is to use co-simulation, as an integrated approach to simulation. This article elaborates on issues important for co-simulation realization and discusses multiple possibilities to justify the particular approach implemented in the here described co-simulation prototype. The prototype is validated with the results obtained from the traditional simulation approach. It is further used in a proof-of-concept case study to demonstrate the applicability of the method and to highlight its benefits. Stability and accuracy of different coupling strategies are analyzed to give a guideline for the required coupling time step.

  5. Energy impact of indoor environmental policy for air-conditioned offices of Hong Kong

    International Nuclear Information System (INIS)

    Wong, L.T.; Mui, K.W.; Shi, K.L.

    2008-01-01

    Air-conditioned office buildings are one of the biggest energy consumers of electricity in developed cities in the subtropical climate regions. A good energy policy for the indoor environment should respond to both the needs of energy conservation and the needs for a desirable indoor healthy environment with a reduction in carbon dioxide (CO 2 ) generation. This study evaluates energy implications and the corresponding CO 2 generation of some indoor environmental policies for air-conditioned office buildings in the subtropical climate. In particular, the thermal energy consumption in an air-conditioned office building was evaluated by the heat gains through the building fabric, the transport of outdoor fresh air for ventilation, and the heat generated by the occupant and equipment in the space. With the Monte-Carlo sampling technique and the parameters from the existing office building stocks of Hong Kong, the energy consumption profiles of air-conditioned office buildings in Hong Kong were evaluated. Energy consumption profiles were simulated for certain indoor environmental quality (IEQ) policies on indoor air temperature and CO 2 concentration settings in the offices, with other building parameters remaining unchanged. The impact assessment and the regression models described in this study may be useful for evaluation of energy performances of IEQ policies. They will also be useful for the promotion of energy-saving measures in air-conditioned office buildings in Hong Kong. This study presented a useful source of references for policymakers, building professionals and end users to quantify the energy and environmental impacts due to an IEQ policy for air-conditioned office buildings

  6. Change of offices for the FAP Department

    CERN Multimedia

    FAP Department

    2016-01-01

    The FAP Department would like to inform personnel that, due to office renovation work, a number of FAP services currently located on the third floor of building 4 and on the first floor of building 33 will move to temporary offices in building 653 as from late June.   The following services will be relocated to: Accounting services (J. Robinson): FAP-ACC-AP – Accounts Payable, to bldg 653-R-008 – C. Marme FAP-ACC-GA – General Accounting, to bldg 653-1-007 – C. Poncet FAP-ACC-PA – Salary Office, to bldg 653-R-011 – S. Baudat FAP-ACC-PA – Claims, to bldg 653-R-007 – S. Baudat   And the section FAP-TPR-MI - Monitoring and reporting (L. Lockwood) will be located in the office 653-1-016.   The removals will take place from Thursday 30 June until Tuesday 5 July 2016 inclusive and during this period, telephone and e-mail contact may be disrupted. Temporary office number...

  7. Integrated Semantics Service Platform for the Internet of Things: A Case Study of a Smart Office

    Science.gov (United States)

    Ryu, Minwoo; Kim, Jaeho; Yun, Jaeseok

    2015-01-01

    The Internet of Things (IoT) allows machines and devices in the world to connect with each other and generate a huge amount of data, which has a great potential to provide useful knowledge across service domains. Combining the context of IoT with semantic technologies, we can build integrated semantic systems to support semantic interoperability. In this paper, we propose an integrated semantic service platform (ISSP) to support ontological models in various IoT-based service domains of a smart city. In particular, we address three main problems for providing integrated semantic services together with IoT systems: semantic discovery, dynamic semantic representation, and semantic data repository for IoT resources. To show the feasibility of the ISSP, we develop a prototype service for a smart office using the ISSP, which can provide a preset, personalized office environment by interpreting user text input via a smartphone. We also discuss a scenario to show how the ISSP-based method would help build a smart city, where services in each service domain can discover and exploit IoT resources that are wanted across domains. We expect that our method could eventually contribute to providing people in a smart city with more integrated, comprehensive services based on semantic interoperability. PMID:25608216

  8. Integrated Semantics Service Platform for the Internet of Things: A Case Study of a Smart Office

    Directory of Open Access Journals (Sweden)

    Minwoo Ryu

    2015-01-01

    Full Text Available The Internet of Things (IoT allows machines and devices in the world to connect with each other and generate a huge amount of data, which has a great potential to provide useful knowledge across service domains. Combining the context of IoT with semantic technologies, we can build integrated semantic systems to support semantic interoperability. In this paper, we propose an integrated semantic service platform (ISSP to support ontological models in various IoT-based service domains of a smart city. In particular, we address three main problems for providing integrated semantic services together with IoT systems: semantic discovery, dynamic semantic representation, and semantic data repository for IoT resources. To show the feasibility of the ISSP, we develop a prototype service for a smart office using the ISSP, which can provide a preset, personalized office environment by interpreting user text input via a smartphone. We also discuss a scenario to show how the ISSP-based method would help build a smart city, where services in each service domain can discover and exploit IoT resources that are wanted across domains. We expect that our method could eventually contribute to providing people in a smart city with more integrated, comprehensive services based on semantic interoperability.

  9. Integrated semantics service platform for the Internet of Things: a case study of a smart office.

    Science.gov (United States)

    Ryu, Minwoo; Kim, Jaeho; Yun, Jaeseok

    2015-01-19

    The Internet of Things (IoT) allows machines and devices in the world to connect with each other and generate a huge amount of data, which has a great potential to provide useful knowledge across service domains. Combining the context of IoT with semantic technologies, we can build integrated semantic systems to support semantic interoperability. In this paper, we propose an integrated semantic service platform (ISSP) to support ontological models in various IoT-based service domains of a smart city. In particular, we address three main problems for providing integrated semantic services together with IoT systems: semantic discovery, dynamic semantic representation, and semantic data repository for IoT resources. To show the feasibility of the ISSP, we develop a prototype service for a smart office using the ISSP, which can provide a preset, personalized office environment by interpreting user text input via a smartphone. We also discuss a scenario to show how the ISSP-based method would help build a smart city, where services in each service domain can discover and exploit IoT resources that are wanted across domains. We expect that our method could eventually contribute to providing people in a smart city with more integrated, comprehensive services based on semantic interoperability.

  10. US Department of Energy Grand Junction Projects Office Remedial Action Project, final report of the decontamination and decommissioning of Building 36 at the Grand Junction Projects Office Facility

    International Nuclear Information System (INIS)

    Widdop, M.R.

    1996-08-01

    The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission's domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJPO Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, also is the remedial action contractor. Building 36 was found to be radiologically contaminated and was demolished in 1996. The soil beneath the building was remediated in accordance with identified standards and can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building

  11. US Department of Energy Grand Junction Projects Office Remedial Action Project. Final report of the decontamination and decommissioning of Building 52 at the Grand Junction Projects Office Facility

    International Nuclear Information System (INIS)

    Krabacher, J.E.

    1996-08-01

    The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission's domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJPO Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, also was the remedial action contractor. Building 52 was found to be radiologically contaminated and was demolished in 1994. The soil area within the footprint of the building has been remediated in accordance with the identified standards and the area can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building

  12. Public Flat in Indonesia, Their Role in Highly Densed City: Legal Aspect Review and Prototype Assessment

    Science.gov (United States)

    Paramita, Beta; Perdana Khidmat, Rendy; Fukuda, Hiroatsu

    2018-05-01

    An affordable vertical house, which is known as rusun in Indonesian term becomes the utopia of a compact city. The rusun to be the main actor contributing to the creation of liveable comfort in dense areas by relocating squatters and slum inhabitants to better living places. Technical guidelines and building standards play a major role in a building’s environmental impact. These standards will be reviewed based on their impact on building performance. There are two prototypes of rusun referenced in 05/PRT/M/2007, and the assessment of these prototypes has been done by using ENVi-met. The meteorological data for the ENVI-met configuration input is adapted to the same weather and climate conditions taken from the data measured on June 13th, 2012. The analysis of this assessment will focus on building orientation, building length, building height, and also the microclimate which is impacted by these prototypes. Based on the assessment, it is recommended that the layout of outdoor space on the north side should provide as much green coverage as possible, either for shadowing or for the benefit of its albedo. The simulation shows that building ratio of 1:3 produces higher wind speed, which also controls air temperature and humidity.

  13. Light Pipe Transporter for High-rise Office Building in Tropical Climate

    Directory of Open Access Journals (Sweden)

    Christopher Yii Sern Heng

    2016-01-01

    Full Text Available Daylight has known to bring benefits for human, psychologically and physiologically. It also provides better indoor environment quality and thus increase the performance and productivity of office workers as stated by Paevere (2009. However, due to economic reasons, the current practice of using deep open plan building has cause a dent to having daylight in the interior spaces, which cause a dependency on artificial lighting. Hence, to provide daylight in deep interior, light distribution system is needed. Although so, according to Hansen (2003, most of the systems can only illuminate up to 8m-10m depth. Therefore, light pipe (LP plays an essential role where it can illuminate up to 20m depth. LP’s efficiency depends on the 3 main components; collector, transporter and extractor. This research explores the effectiveness of horizontal LP through different type of transporter’s shapes which includes rectangular, triangular, square and semi-circle. Previous studies have shown differences of efficiency on the shaped while using vertical LP. This research’s analysis was done using a computer simulation, Integrated Environment Solution: Virtual Environment (IESVE, where DF of each shapes were compared to MS 1525:2007 benchmark. The viability of the software was also validated though an assessment with a physical scaled-model experiment that was conducted in an open car park in Universiti Teknologi Malaysia, Johor, Malaysia. The results from the simulation showed that semi-circle shaped transporter offered the same efficiency as rectangular shaped. These findings will promote the usage of LP in buildings as it decreases the costing for LP.

  14. Energy Savings Potential of Flexible and Adaptive HVAC Distribution Systems for Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Loftness, Vivian; Brahme, Rohini; Mondazzi, Michelle; Vineyard, Edward; MacDonald, Michael

    2002-06-01

    It has been understood by architects and engineers that office buildings with easily re-configurable space and flexible mechanical and electrical systems are able to provide comfort that increases worker productivity while using less energy. Raised floors are an example of how fresh air, thermal conditioning, lighting needs, and network access can be delivered in a flexible manner that is not ''embedded'' within the structure. What are not yet documented is how well these systems perform and how much energy they can save. This area is being investigated in phased projects of the 21st Century Research Program of the Air-conditioning and Refrigeration Technology Institute. For the initial project, research teams at the Center for Building Performance and Diagnostics, Pittsburgh, Pennsylvania, and Oak Ridge National Laboratory, Oak Ridge, Tennessee, documented the diversity, performance, and incidence of flexible and adaptive HVAC systems. Information was gathered worldwide from journal and conference articles, case studies, manufactured products and assemblies, and interviews with design professionals. Their report thoroughly describes the variety of system types along with the various design alternatives observed for plenums, diffusers, individual control, and system integration. Many of the systems are illustrated in the report and the authors provide quantitative and qualitative comparisons. Among conclusions regarding key design issues, and barriers to widespread adoption, the authors state that flexible and adaptive HVAC systems, such as underfloor air, perform as well if not better than ceiling-based systems. Leading engineers have become active proponents after their first experience, which is resulting in these flexible and adaptive HVAC systems approaching 10 percent of the new construction market. To encourage adoption of this technology that improves thermal comfort and indoor air quality, follow-on work is required to further document

  15. 2010 energy benchmarking report performance of the Canadian office sector

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-04-15

    In 2009, REALpac set a target of reducing energy consumption in office buildings to 20 equivalent kilowatt-hours per square foot by 2015. Following this, REALpac launched a national energy benchmarking survey to create a baseline for building energy performance across Canada; this paper provides the results of that survey. The survey was carried out using a tool which can measure energy use in a meaningful way using building characteristics data and energy use data from utility bills. The survey was conducted on 2009 data, 261 office buildings submitted their data which were then analyzed to provide trends and a baseline. Results showed a variety and diversity of performances and a 28.7 ekWh/ft2 annual mean building energy use intensity was found. This survey demonstrated that several office building owners and managers are taking steps to monitor and minimize energy use in their buildings.

  16. Solar heating and cooling system for an office building at Reedy Creek Utilities

    Energy Technology Data Exchange (ETDEWEB)

    1978-08-01

    This final report describes in detail the solar energy system installed in a new two-story office building at the Reedy Creek Utilities Company, which provides utility service to Walt Disney World at Lake Buena Vista, Florida. The solar components were partly funded by the Department of Energy under Contract EX-76-C-01-2401, and the technical management was by NASA/George C. Marshall Space Flight Center. The solar energy system application is 100 percent heating, 80 percent cooling, and 100 percent hot water. The collector is a modular cylindrical concentrator type with an area of 3.840 square feet. The storage medium is water with a capacity of 10,000 gallons hot and 10,000 gallons chilled. Design, construction, operation, cost, maintenance, and performance are described in depth. Detailed drawings are included.

  17. Building certification schemes and the quality of indoor environment

    DEFF Research Database (Denmark)

    Da Silva, Nuno Alexandre Faria

    Building certification schemes create a new standard for the built environment reflecting the growing environmental consciousness and the need for “green buildings”. They are expected to signify an outstanding quality and excellence. Buildings, which receive a high degree of certification......, providing information on the performance of building certification schemes in relation to IEQ and ratings of building occupants. Then, information was collected on IEQ in existing office buildings certified as green buildings with particular focus on the work performance indicators, acute health symptoms......, and perceptions and comfort. Information on IEQ in the existing buildings was collected through field campaigns. They comprised measurements in 6 office buildings in Singapore certified using the Green Mark (GM) Certification Scheme. The measurements were additionally carried out in 6 office buildings...

  18. Office of the Chief Financial Officer Strategic Plan2008-2012

    Energy Technology Data Exchange (ETDEWEB)

    Various

    2007-11-19

    This is an update to the Office of the Chief Financial Officer's (OCFO's) multi-year strategy to continue to build a highly effective, efficient and compliant financial and business approach to support the scientific mission of Lawrence Berkeley National Laboratory (LBNL). The guiding principles of this strategy are to provide the greatest capability for the least cost while continually raising the standards of professional financial management in service to the LBNL science mission.

  19. Design and Construction of Prototype Dark Matter Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Peter Fisher

    2012-03-23

    The Lepton Quark Studies (LQS) group is engaged in searching for dark matter using the Dark Matter Time Projection Chamber (DMTPC) at the Waste Isolation Pilot Plant (WIPP) (Carlsbad, NM). DMTPC is a direction-sensitive dark matter detector designed to measure the recoil direction and energy deposited by fluorine nuclei recoiling from the interaction with incident WIMPs. In the past year, the major areas of progress have been: to publish the first dark matter search results from a surface run of the DMTPC prototype detector, to build and install the 10L prototype in the underground laboratory at WIPP which will house the 1 m{sup 3} detector, and to demonstrate charge and PMT readout of the TPC using prototype detectors, which allow triggering and {Delta}z measurement to be used in the 1 m{sup 3} detector under development.

  20. Environmental Noise Exposure On Occupants In Naturally Ventilated Open-Plan Offices Case Of Selected Offices In Kumasi Ghana

    Directory of Open Access Journals (Sweden)

    Koranteng

    2015-08-01

    Full Text Available The design of buildings in public educational institutions in Ghana predominantly adopts open-plan offices that are naturally ventilated with the aid of operable windows for reasons such as achieving adaptable spaces improved social climate and effective ventilation. However adoption of open-plan naturally ventilated offices in these educational institutions expose occupants to noise that emanates indoors and from outdoor sources which can interfere with and impede work performance. The study aimed at assessing noise exposure levels and occupants satisfaction with noise level in selected naturally ventilated open-plan offices in Ghana. The study employed an empirical assessment of the noise levels in and around three of the office buildings using a PCE222 Digital Sound Level Meter and a survey involving interviews to assess workers satisfaction of noise levels of the open-plan offices at the Kwame Nkrumah University of Science and Technology in Kumasi. The results show that mean outdoor noise levels for offices ranged from 11 per cent below to 5 per cent above the WHO permissible limits while mean indoor noise levels exceeded the limit by between 20-40 per cent during the course of the day. In spite of the high levels of noise occupants generally considered the overall noise level in their offices as acceptable. Likewise the results indicate that there are no significant differences in occupants exposure to noise from their various sitting positions in an office space and floor levels in an office building. The paper recommends strategies to manage and improve ambient noise quality within naturally ventilated open-plan office spaces in Ghana. The study will be of relevance as a useful guide to organizations and policy makers concerned with built environmental issues.

  1. Improving thermal comfort in office practice: biomimetic comfort profiles

    NARCIS (Netherlands)

    Zeiler, W.; Houten, van M.A.; Boxem, G.; Noom, P.; Velden, van der J.A.J.

    2009-01-01

    In the office building of Kropman in Utrecht a number of measurements were done, by means of NEN-EN-ISO 7726, to determine thermal comfort in the office building. Also two enquiries were held to determine the thermal comfort perception of the employees. The evaluation of the measurements and

  2. Auxiliary buildings

    International Nuclear Information System (INIS)

    Lakner, I.; Lestyan, E.

    1979-01-01

    The nuclear power station represents a complicated and a particular industrial project. Consequently, the design of the auxiliary buildings serving the power station (offices, kitchen, refreshment room, workshops, depots, water treatment plant building, boiler houses, etc.) requires more attention than usual. This chapter gives a short survey of the auxiliary buildings already completed and discusses the problems of their design, location and structure. (author)

  3. An approach to build knowledge base for reactor accident diagnostic system using statistical method

    International Nuclear Information System (INIS)

    Kohsaka, Atsuo; Yokobayashi, Masao; Matsumoto, Kiyoshi; Fujii, Minoru

    1988-01-01

    In the development of a rule based expert system, one of key issues is how to build a knowledge base (KB). A systematic approach has been attempted for building an objective KB efficiently. The approach is based on the concept that a prototype KB should first be generated in a systematic way and then it is to be modified and/or improved by expert for practical use. The statistical method, Factor Analysis, was applied to build a prototype KB for the JAERI expert system DISKET using source information obtained from a PWR simulator. The prototype KB was obtained and the inference with this KB was performed against several types of transients. In each diagnosis, the transient type was well identified. From this study, it is concluded that the statistical method used is useful for building a prototype knowledge base. (author)

  4. Study of a two-pipe chilled beam system for both cooling and heating of office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Norouzi, R. [Univ. of Boraes, Boraes (Sweden); Hultmark, G. [Lindab Comfort A/S, Farum (Denmark); Afshari, A. (ed.); Bergsoee, N.C. [Aalborg Univ.. Statens Byggeforskningsinstitut (SBi), Copenhagen (Denmark)

    2013-05-15

    The main aim of this master thesis was to investigate possibilities and limitations of a new system in active chilled beam application for office buildings. Lindab Comfort A/S pioneered the presented system. The new system use two-pipe system, instead of the conventional active chilled beam four-pipe system for heating and cooling purposes. The Two-Pipe System which is studied in this project use high temperature cooling and low temperature heating with water temperatures of 20 deg. C to 23 deg. C, available for free most of the year. The system can thus take advantage of renewable energy. It was anticipated that a Two-Pipe System application enables transfer of energy from warm spaces to cold spaces while return flows, from cooling and heating beams, are mixed. BSim software was chosen as a simulation tool to model a fictional office building and calculate heating and cooling loads of the building. Moreover, the effect of using outdoor air as a cooling energy source (free cooling) is investigated through five possible scenarios in both the four pipe system and the Two-Pipe System. The calculations served two purposes. Firstly, the effect of energy transfer in the Two-Pipe System were calculated and compared with the four pipe system. Secondly, free cooling effect was calculated in the Two-Pipe System and compared with the four pipe system. The simulation results showed that the energy transfer, as an inherent characteristic in the Two-Pipe System, is able to reduce up to 3 % of annual energy use compared to the four pipe system. Furthermore, different free cooling applications in the Two-Pipe System and the four pipe system respectively showed that the Two-Pipe System requires 7-15 % less total energy than the four pipe system in one year. In addition, the Two-Pipe System can save 18-57 % of annual cooling energy when compared to the four pipe system. (Author)

  5. Sustainable enterprise in office buildings of small businesses; Duurzaam ondernemen in het kantoorhoudende MKB

    Energy Technology Data Exchange (ETDEWEB)

    Bertens, C. [Panteia/EIM, Zoetermeer (Netherlands); Muizer, A. [Panteia/Consult, Zoetermeer (Netherlands)

    2012-05-15

    SMEs in the Netherlands will increasingly face stricter sustainability criteria in procurement procedures. A study has been carried out among 375 small businesses that will provide insight into the state of sustainability in office buildings of SMEs. Attention is paid to the importance of sustainability, measures taken with regard to sustainable enterprising, plans and ambitions; and required support [Dutch] Het MKB krijgt in toenemende mate te maken met strengere duurzaamheidseisen in aanbestedingsprocedures. Er is onderzoek gedaan onder 375 bedrijven waarmee inzicht wordt gegeven in de stand van zaken van duurzaam ondernemen in het kantoorhoudend MKB. Het gaat in grote lijnen om de volgende aspecten: het belang van duurzaam ondernemen; genomen maatregelen op het gebied van duurzaam ondernemen; plannen en ambities; benodigde ondersteuning.

  6. Offices for living in : An instrument for measuring the potential for transforming offices into homes

    NARCIS (Netherlands)

    Geraedts, Rob P.; van der Voordt, Theo

    2003-01-01

    A large number of office premises seem difficult to rent out because they no longer meet the demands of the market. A solution must be found for these premises and also for office buildings that have been empty for longer periods. Reallocation or transformation to other functions such as homes can

  7. 4 CFR 25.3 - Admission to the GAO building.

    Science.gov (United States)

    2010-01-01

    ... 4 Accounts 1 2010-01-01 2010-01-01 false Admission to the GAO building. 25.3 Section 25.3 Accounts GOVERNMENT ACCOUNTABILITY OFFICE GENERAL PROCEDURES CONDUCT IN THE GOVERNMENT ACCOUNTABILITY OFFICE BUILDING AND ON ITS GROUNDS § 25.3 Admission to the GAO building. A person may be admitted to the GAO Building...

  8. Ares I-X Ground Diagnostic Prototype

    Science.gov (United States)

    Schwabacher, Mark A.; Martin, Rodney Alexander; Waterman, Robert D.; Oostdyk, Rebecca Lynn; Ossenfort, John P.; Matthews, Bryan

    2010-01-01

    The automation of pre-launch diagnostics for launch vehicles offers three potential benefits: improving safety, reducing cost, and reducing launch delays. The Ares I-X Ground Diagnostic Prototype demonstrated anomaly detection, fault detection, fault isolation, and diagnostics for the Ares I-X first-stage Thrust Vector Control and for the associated ground hydraulics while the vehicle was in the Vehicle Assembly Building at Kennedy Space Center (KSC) and while it was on the launch pad. The prototype combines three existing tools. The first tool, TEAMS (Testability Engineering and Maintenance System), is a model-based tool from Qualtech Systems Inc. for fault isolation and diagnostics. The second tool, SHINE (Spacecraft Health Inference Engine), is a rule-based expert system that was developed at the NASA Jet Propulsion Laboratory. We developed SHINE rules for fault detection and mode identification, and used the outputs of SHINE as inputs to TEAMS. The third tool, IMS (Inductive Monitoring System), is an anomaly detection tool that was developed at NASA Ames Research Center. The three tools were integrated and deployed to KSC, where they were interfaced with live data. This paper describes how the prototype performed during the period of time before the launch, including accuracy and computer resource usage. The paper concludes with some of the lessons that we learned from the experience of developing and deploying the prototype.

  9. The Users Office returns to its premises

    CERN Multimedia

    2005-01-01

    The renovation work on the Users Office, which began on 29 November, was completed last week. The Office's staff have now returned to their modernised and more spacious premises in Building 61. For four months, the Users' Office was housed in Building 2-R-030 thanks to the LHCb experiment collaboration, which was kind enough to temporarily loan some office space. For 15 years, the team has been helping Users with their administrative tasks. It provides them with all the information necessary on the procedures to be followed after their arrival at CERN as well as on cultural activities in the region. Since the beginning of January, the team is also looking after the Unpaid Associates. CERN hosts 4489 Users from Member States and 1909 from non-Members States, representing over 50 nationalities.

  10. Case-study of thermo active building systems in Japanese climate

    DEFF Research Database (Denmark)

    Li, Rongling; Yoshidomi, Togo; Ooka, Ryozo

    2015-01-01

    Thermo active building systems (TABS) have been applied in office buildings as a promising energy efficient solution in many European countries. The utilization of building thermal mass helps to provide high quality thermal environments with less energy consumption. However, the concept of TABS...... is entirely new in Japan. This paper introduces and evaluates TABS under Tokyo weather conditions to clarify the potential of use TABS in Japan. Cooling capacity of thermo active building systems used in an office building was evaluated by means of dynamic simulations. Two central rooms of the office were...

  11. Understanding the potential of facilities managers to be advocates for energy efficiency retrofits in mid-tier commercial office buildings

    International Nuclear Information System (INIS)

    Curtis, Jim; Walton, Andrea; Dodd, Michael

    2017-01-01

    Realising energy efficiency opportunities in new commercial office buildings is an easier task than retrofitting older, mid-tier building stock. As a result, a number of government programs aim to support retrofits by offering grants, upgrades, and energy audits to facilitate energy efficiency opportunities. This study reports on a state government program in Victoria, Australia, where the uptake of such offerings was lower than expected, prompting the program team to consider whether targeting facilities managers (FMs), rather than building owners, might be a better way of delivering the program. The influences and practices of FMs that impact on their ability to be advocates for energy efficiency were explored. The results revealed that complex building ownership arrangements, poor communication skills, isolation from key decision making processes, a lack of credible business cases and information, split incentives, and the prospect of business disruptions can all impact on FMs’ ability to drive organizational change. Future program efforts should continue to interrogate the social context of retrofits in mid-tier buildings, including other influences and influencers beyond FMs, and adapt accordingly. - Highlights: • Energy efficiency retrofits of older commercial buildings can be a challenge. • Government support for retrofits is not always taken up by building owners. • Targeting facilities managers (FMs) to encourage retrofits is proposed. • FMs’ ability to be advocates for energy efficiency is constrained. • Government offerings need to better fit with the realities of the problem.

  12. Physical Quality of Air and Sick Building Syndrome in Office Employees of “X” Company in Jakarta

    Directory of Open Access Journals (Sweden)

    Rama Putra Effendi

    2014-08-01

    Full Text Available Physical symptoms had led to the suggestion that a disease called Sick Building Syndrome (SBS occured to the office of “X” Company in the city of Jakarta. This research that used a random sampling technique examined the physical air quality of the “X” Company, such as indoor temperature and humidity aspects, the SBS cases of 90 workers. Research results on the Company “X” office workers showed that, (1 47.8% workers had cases of SBS; and, (2 a value of 0.714 was acquired from the result of bivariate analysis using Chi square statistics program with p value of 0.325 and RP of 95 percent. This signifies that there were no relations between indoor temperature and humidity with the SBS cases of the Company “X” workers in Jakarta City. Possibilities of other factors were found to trigger the SBS symptoms such as chemical and microbiological factors (from work tools and facilities, and psychosocial factor (from the workers themselves

  13. Design and construction of a prototype to obtain TeO2

    International Nuclear Information System (INIS)

    Roque H, I.

    1997-01-01

    At the National Institute of Nuclear Research is developed the process to produce the radioisotope Iodine 131 which is employed in medicine with therapeutical purposes. The raw material to produce iodine 131 is tellurium dioxide (TeO 2 ). TeO 2 is intended to be produced from a prototype being this aim of this thesis named D esign and construction of a prototype to obtain TeO 2 . The TeO 2 obtained must have specific physicochemical characteristics, being necessary an special design of a prototype which will guarantee the quality of tellurium dioxide obtention. Design and building the final prototype project, was developed in to three stages. At the first stage, the TeO 2 was obtained at the laboratory, this allows to know the basic reaction characteristics. The second stage purpose, was to work with an former prototype which allowed to produce 100 g of tellurium dioxide. In the last stage a depurated chemical process parameters was made and the prototype was refined in regard to its mechanical design, giving us as result the final prototype. With this final prototype, the production reaches 2 Kg/week of tellurium dioxide with the best physicochemical properties which is to be employed as raw material in order to produce iodine 131. (Author)

  14. Energy Prediction versus Energy Performance of Green Buildings in Malaysia. Comparison of Predicted and Operational Measurement of GBI Certified Green Office in Kuala Lumpur

    Directory of Open Access Journals (Sweden)

    Zaid Suzaini M

    2016-01-01

    Full Text Available Forward from the sustainability agenda of Brundtland in 1987 and the increasing demand for energy efficient buildings, the building industry has taken steps in meeting the challenge of reducing its environmental impact. Initiatives such as ‘green’ or ‘sustainable’ design have been at the forefront of architecture, while green assessment tools have been used to predict the energy performance of building during its operational phase. However, there is still a significant hap between predicted or simulated energy measurements compared to actual operational energy consumption, or is more commonly referred as the ‘performance gap’. This paper tries to bridge this gap by comparing measured operational energy consumption of a Green Building Index (GBI certified office building in Kuala Lumpur, with its predicted energy rating qualification.

  15. Characterization of commercial building appliances. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Patel, R.F.; Teagan, P.W.; Dieckmann, J.T.

    1993-08-01

    This study focuses on ``other`` end-uses category. The purpose of this study was to determine the relative importance of energy end-use functions other than HVAC and lighting for commercial buildings, and to identify general avenues and approaches for energy use reduction. Specific energy consuming technologies addressed include non-HVAC and lighting technologies in commercial buildings with significant energy use to warrant detailed analyses. The end-uses include office equipment, refrigeration, water heating, cooking, vending machines, water coolers, laundry equipment and electronics other than office equipment. The building types include offices, retail, restaurants, schools, hospitals, hotels/motels, grocery stores, and warehouses.

  16. Use of artificial intelligence techniques for visual inspection systems prototyping. Application to magnetoscopy

    International Nuclear Information System (INIS)

    Pallas, Christophe

    1987-01-01

    The automation of visual inspection is a complex task that requires collaboration between experts, for example inspection specialist, vision specialist. on-line operators. Solving such problems through prototyping promotes this collaboration: the use of a non specific programming environment allows rapid, concrete checking of method validity, thus leading incrementally to the final system. In this context, artificial intelligence techniques permit easy, extensible, and modular design of the prototype, together with heuristic solution building. We define and achieve the SPOR prototyping environment, based on object-oriented programming and rules-basis managing. The feasibility and the validity of an heuristic method for automated visual inspection in fluoroscopy have been proved through prototyping in SPOR. (author) [fr

  17. Architectures of prototypes and architectural prototyping

    DEFF Research Database (Denmark)

    Hansen, Klaus Marius; Christensen, Michael; Sandvad, Elmer

    1998-01-01

    together as a team, but developed a prototype that more than fulfilled the expectations of the shipping company. The prototype should: - complete the first major phase within 10 weeks, - be highly vertical illustrating future work practice, - continuously live up to new requirements from prototyping......This paper reports from experience obtained through development of a prototype of a global customer service system in a project involving a large shipping company and a university research group. The research group had no previous knowledge of the complex business of shipping and had never worked...... sessions with users, - evolve over a long period of time to contain more functionality - allow for 6-7 developers working intensively in parallel. Explicit focus on the software architecture and letting the architecture evolve with the prototype played a major role in resolving these conflicting...

  18. Performance of office buildings from a user's perspective

    NARCIS (Netherlands)

    van der Voordt, Theo; Maarleveld, M.

    2006-01-01

    In the field of environmental psychology a long tradition exists in Post-Occupancy Evaluation (POE) or building-in-use studies. Nowadays facility managers and real estate managers seem to show a growing interest in ex post evaluation of buildings, too, particularly in connection to ex ante

  19. Collaborative Prototyping

    DEFF Research Database (Denmark)

    Bogers, Marcel; Horst, Willem

    2014-01-01

    of the prototyping process, the actual prototype was used as a tool for communication or development, thus serving as a platform for the cross-fertilization of knowledge. In this way, collaborative prototyping leads to a better balance between functionality and usability; it translates usability problems into design......This paper presents an inductive study that shows how collaborative prototyping across functional, hierarchical, and organizational boundaries can improve the overall prototyping process. Our combined action research and case study approach provides new insights into how collaborative prototyping...... can provide a platform for prototype-driven problem solving in early new product development (NPD). Our findings have important implications for how to facilitate multistakeholder collaboration in prototyping and problem solving, and more generally for how to organize collaborative and open innovation...

  20. Prototype of sun projector device

    Science.gov (United States)

    Ihsan; Dermawan, B.

    2016-11-01

    One way to introduce astronomy to public, including students, can be handled by solar observation. The widely held device for this purpose is coelostat and heliostat. Besides using filter attached to a device such as telescope, it is safest to use indirect way for observing the Sun. The main principle of the indirect way is deflecting the sun light and projecting image of the sun on a screen. We design and build a simple and low-cost astronomical device, serving as a supplement to increase public service, especially for solar observation. Without using any digital and intricate supporting equipment, people can watch and relish image of the Sun in comfortable condition, i.e. in a sheltered or shady place. Here we describe a design and features of our prototype of the device, which still, of course, has some limitations. In the future, this prototype can be improved for more efficient and useful applications.

  1. Building Services Requests Subsystem (BSRS) -

    Data.gov (United States)

    Department of Transportation — Lotus Notes workflow application used for the submission, processing, tracking and reporting of building service related requiests. Enables regional office building...

  2. Automated Loading and Unloading of the Stratasys FDM 1600 Rapid Prototyping System

    OpenAIRE

    Brockmeier, Oivind

    2000-01-01

    Rapid prototyping systems have advanced significantly with respect to material capabilities, fabrication speed, and surface quality. However, build jobs are still manually activated one at a time. The result is non-productive machine time whenever an operator is not at hand to make a job changeover. A low-cost auxiliary system, named Continuous Layered Manufacturing (CLM), has been developed to automatically load and unload the FDM 1600 rapid prototyping system (Stratasys, Inc.). The modifica...

  3. Converging Redundant Sensor Network Information for Improved Building Control

    Energy Technology Data Exchange (ETDEWEB)

    Dale Tiller; D. Phil; Gregor Henze; Xin Guo

    2007-09-30

    This project investigated the development and application of sensor networks to enhance building energy management and security. Commercial, industrial and residential buildings often incorporate systems used to determine occupancy, but current sensor technology and control algorithms limit the effectiveness of these systems. For example, most of these systems rely on single monitoring points to detect occupancy, when more than one monitoring point could improve system performance. Phase I of the project focused on instrumentation and data collection. During the initial project phase, a new occupancy detection system was developed, commissioned and installed in a sample of private offices and open-plan office workstations. Data acquisition systems were developed and deployed to collect data on space occupancy profiles. Phase II of the project demonstrated that a network of several sensors provides a more accurate measure of occupancy than is possible using systems based on single monitoring points. This phase also established that analysis algorithms could be applied to the sensor network data stream to improve the accuracy of system performance in energy management and security applications. In Phase III of the project, the sensor network from Phase I was complemented by a control strategy developed based on the results from the first two project phases: this controller was implemented in a small sample of work areas, and applied to lighting control. Two additional technologies were developed in the course of completing the project. A prototype web-based display that portrays the current status of each detector in a sensor network monitoring building occupancy was designed and implemented. A new capability that enables occupancy sensors in a sensor network to dynamically set the 'time delay' interval based on ongoing occupant behavior in the space was also designed and implemented.

  4. TNT Green Office. NESK Final Report; TNT Green Office, Hoofddorp. NESK Eindrapportage

    Energy Technology Data Exchange (ETDEWEB)

    Van der Spek, C; Van Rheenen, M [OVG Projectontwikkeling, Rotterdam (Netherlands)

    2011-12-15

    The aim of the collaboration between TNT (courier and express services) and Triodos/OVG (bank and project developer) was to realize CO2 free Green Offices in the Netherlands. The building is both developed and exploited by the same parties based on an innovative contract in which design, construction and maintenance and management are arranged. These parties are also responsible for the sustainable energy system of the building [Dutch] Doelstelling van de samenwerking tussen TNT (koerier en expresdiensten) en Triodos/OVG (bank en projectontwikkelaar) was het realiseren van CO2-emissievrije Green Offices in Nederland. Hierbij wordt het gebouw ontwikkeld en geexploiteerd door dezelfde partijen op basis van een innovatief contract waarin ontwerp, bouw, onderhoud en beheer zijn vastgelegd. Deze partijen zijn ook verantwoordelijk voor de duurzame energievoorziening van het gebouw.

  5. Energy Refurbishment of an Office Building with Hybrid Photovoltaic System and Demand-Side Management

    Directory of Open Access Journals (Sweden)

    Giovani Almeida Dávi

    2017-08-01

    Full Text Available On-site photovoltaic (PV and battery systems intend to improve buildings energy performance, however battery costs and monetary incentives are a major drawback for the introduction of these technologies into the electricity grids. This paper proposes an energy refurbishment of an office building based on multi-objective simulations. An innovative demand-side management approach is analyzed through the PV and battery control with the purpose of reducing grid power peaks and grid imported energy, as well as improving the project economy. Optimization results of load matching and grid interaction parameters, complemented with an economic analysis, are investigated in different scenarios. By means of battery use, the equivalent use of the grid connection is reduced by 12%, enhancing the grid interaction potential, and 10% of load matching rates can be increased. Project improvements indicate the grid connection capacity can be reduced by 13% and significant savings of up to 48% are achieved on yearly bills. The economy demonstrates the grid parity is only achieved for battery costs below 100 €/kWh and the payback period is large: 28 years. In the case with only PV system, the grid parity achieves better outcomes and the payback time is reduced by a half, making this a more attractive option.

  6. Brand new hall in the main building

    CERN Multimedia

    Corinne Pralavorio

    2014-01-01

    The renovation of the UNIQA and post office premises is getting under way, with their reopening scheduled for the spring.   The renovation of the large hall in the main building (Building 500) has finally reached the home straight. As of this week, building contractors will get to work on the last part – the offices of UNIQA and La Poste. In the last week of November, the two concessions moved their offices across Route Scherrer to the same part of Building 510 where UBS was temporarily housed during the bank’s refurbishment. Their services were therefore unavailable for one day. The renovation work will last until the spring, with the new offices expected to open in May 2015. Between now and then, the windows and insulation will be completely refitted, with a view to reducing heat loss considerably, and, above all, the premises will be modernised to improve customer reception and service. For example, UNIQA’s new premises will feature a confidential area, guarantee...

  7. Thermal phase shift - Optimisation and prototype; Dephaseur thermique. Optimisation et prototype integre

    Energy Technology Data Exchange (ETDEWEB)

    Hollmuller, P.; Lachal, B.

    2006-07-01

    This illustrated report for the Swiss Federal Office of Energy (SFOE) summarises the work done at the University of Geneva's Centre for Research into Energy Problems on a new concept for the storage of thermal energy in ventilation systems in order to reduce the effect of daytime heating of the fresh air taken into the system. The study involved the development of prototypes using water as a storage medium and the determination of the direction which the development of an industrial product should take. Work done in the laboratory is described, as is the configuration of the storage elements examined. These consisted of PVC tubes filled with water on the one hand, and concrete slabs on the other.

  8. Effectiveness of a smoke-free policy in lowering secondhand smoke concentrations in offices in China.

    Science.gov (United States)

    Gan, Quan; Hammond, S Katharine; Jiang, Yuan; Yang, Yan; Hu, Teh-Wei

    2008-05-01

    To examine the secondhand smoke (SHS) exposure level in Chinese office buildings and to evaluate the effectiveness of a smoke-free policy in reducing SHS exposure. Survey of smoking policies and measurement of SHS level in 14 office buildings from 10 provinces in China. Smoking in the building significantly elevated the SHS concentrations both in offices with at least one smoker and in offices with no smokers. In one building that recently adopted a smoke-free policy, the nicotine concentrations decreased significantly after the policy was enacted. Enactment of a smoking policy was effective in reducing SHS exposure in the buildings. Nonsmoking office workers in China were exposed to significant levels of SHS at work; both the central and local governments should realize the need to legislate against workplace smoking.

  9. Rethink! prototyping transdisciplinary concepts of prototyping

    CERN Document Server

    Nagy, Emilia; Stark, Rainer

    2016-01-01

    In this book, the authors describe the findings derived from interaction and cooperation between scientific actors employing diverse practices. They reflect on distinct prototyping concepts and examine the transformation of development culture in their fusion to hybrid approaches and solutions. The products of tomorrow are going to be multifunctional, interactive systems – and already are to some degree today. Collaboration across multiple disciplines is the only way to grasp their complexity in design concepts. This underscores the importance of reconsidering the prototyping process for the development of these systems, particularly in transdisciplinary research teams. “Rethinking Prototyping – new hybrid concepts for prototyping” was a transdisciplinary project that took up this challenge. The aim of this programmatic rethinking was to come up with a general concept of prototyping by combining innovative prototyping concepts, which had been researched and developed in three sub-projects: “Hybrid P...

  10. Challenge Based Innovation @ mediterranean - final presentations & prototype expo

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    Challenge Based Innovation @ mediterranean - Final presentations & prototype expo Note - presentation location has been changed to the council chamber (503-1-001) due to the large amount of signups. External participants are guided from the main reception (building 33), more information over email on Wednesday. Prototype presentations are still at IdeaSquare (3179) 18.00 - 19.30, guided walking from the presentations.  Challenge Based Innovation (CBI) is a four month project course, where multidisciplinary student teams and their instructors collaborate with researchers at CERN to discover novel solutions for the future of humankind. The projects are an elaborate mixture, where societal, human-driven needs meet research at CERN. More info about CBI from the course website, cbi-course.com The Gala on 1.12. will introduce the proof-of concept prototypes the five student teams have developed to answer a wide range of societal challenges, inspired by people and r...

  11. Statistical method application to knowledge base building for reactor accident diagnostic system

    International Nuclear Information System (INIS)

    Yoshida, Kazuo; Yokobayashi, Masao; Matsumoto, Kiyoshi; Kohsaka, Atsuo

    1989-01-01

    In the development of a knowledge based expert system, one of key issues is how to build the knowledge base (KB) in an efficient way with keeping the objectivity of KB. In order to solve this issue, an approach has been proposed to build a prototype KB systematically by a statistical method, factor analysis. For the verification of this approach, factor analysis was applied to build a prototype KB for the JAERI expert system DISKET. To this end, alarm and process information was generated by a PWR simulator and the factor analysis was applied to this information to define taxonomy of accident hypotheses and to extract rules for each hypothesis. The prototype KB thus built was tested through inferring against several types of transients including double-failures. In each diagnosis, the transient type was well identified. Furthermore, newly introduced standards for rule extraction showed good effects on the enhancement of the performance of prototype KB. (author)

  12. After-hours Power Status of Office Equipment and Inventory of Miscellaneous Plug-load Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.; Brown, Richard E.; Pinckard, Margaret J.; Busch, John F.

    2004-01-22

    This research was conducted in support of two branches of the EPA ENERGY STAR program, whose overall goal is to reduce, through voluntary market-based means, the amount of carbon dioxide emitted in the U.S. The primary objective was to collect data for the ENERGY STAR Office Equipment program on the after-hours power state of computers, monitors, printers, copiers, scanners, fax machines, and multi-function devices. We also collected data for the ENERGY STAR Commercial Buildings branch on the types and amounts of ''miscellaneous'' plug-load equipment, a significant and growing end use that is not usually accounted for by building energy managers. This data set is the first of its kind that we know of, and is an important first step in characterizing miscellaneous plug loads in commercial buildings. The main purpose of this study is to supplement and update previous data we collected on the extent to which electronic office equipment is turned off or automatically enters a low power state when not in active use. In addition, it provides data on numbers and types of office equipment, and helps identify trends in office equipment usage patterns. These data improve our estimates of typical unit energy consumption and savings for each equipment type, and enables the ENERGY STAR Office Equipment program to focus future effort on products with the highest energy savings potential. This study expands our previous sample of office buildings in California and Washington DC to include education and health care facilities, and buildings in other states. We report data from twelve commercial buildings in California, Georgia, and Pennsylvania: two health care buildings, two large offices (> 500 employees each), three medium offices (50-500 employees), four education buildings, and one ''small office'' that is actually an aggregate of five small businesses. Two buildings are in the San Francisco Bay area of California, five are in

  13. Meta-modeling of occupancy variables and analysis of their impact on energy outcomes of office buildings

    International Nuclear Information System (INIS)

    Wang, Qinpeng; Augenbroe, Godfried; Kim, Ji-Hyun; Gu, Li

    2016-01-01

    accurate estimation of lighting and appliance usage for a better prediction of aggregated energy consumption. Furthermore, it proves that accurate knowledge of the mean profiles is sufficient, that is, stochastic occupancy models do not play a significant role in the prediction of aggregated consumption in a conventional office building where the interaction between the operation of building systems and the spatial and temporal variability of occupancy is weak. When it comes to peak demand behavior, occupancy variability should be taken into account, as static profiles are not able to produce adequate estimates of power duration probabilities close to the power peak.

  14. Structuring front office and back office work in service delivery systems - An empirical study of three design decisions

    NARCIS (Netherlands)

    Zomerdijk, Leonleke G.; de Vries, Jan

    2007-01-01

    Purpose - The aim of this paper is to investigate how the distinction between contact and non-contact activities influences the design of service delivery systems and to identify key design decisions for structuring front office and back office work. Design/methodology/approach - Building on current

  15. Analysis of the Company Officer Management Information System (COMIS) Performance Measurement Software at the United States Naval Academy

    National Research Council Canada - National Science Library

    Larges, Chad

    2000-01-01

    .... In 1999, the Company Officer Management Information System (COMIS) prototype was created to work in conjunction with MIDS to enhance a Company Officer's ability to develop midshipmen and measure their performance...

  16. Design decisions in the front office - back office issue: A Study of Trade-offs in the Financial Services Sector

    OpenAIRE

    Zomerdijk, L.G.

    2005-01-01

    This dissertation presents the results of a research study that involved the development of a framework that provides insight in and so supports design decisions regarding front office and back office activities in service delivery processes. Building on the evidence from five case studies in the financial services sector, three design decisions have been elaborated. They are the definition of front office and back office activities, the decoupling decisions and organizational arrangements. T...

  17. Building energy efficiency in different climates

    International Nuclear Information System (INIS)

    Lam, Joseph C.; Wan, Kevin K.W.; Tsang, C.L.; Yang Liu

    2008-01-01

    Energy simulation was conducted for office buildings in the five major climate zones - severe cold, cold, hot summer and cold winter, mild, and hot summer and warm winter - in China using DOE-2.1E. The primary aim was to investigate the thermal and energy performance of office buildings with centralised heating, ventilation and air conditioning plants in the major climatic zones in China. The computed results were analysed in three aspects - heating load, cooling load and the corresponding building energy consumption. The building peak monthly heating load varied from 142 MW h (1033 MW h cooling) in Hong Kong to 447 MW h (832 MW h cooling) in Harbin. It was also found that passive solar designs could have large energy savings potential in the severe cold and cold climates. In Harbin, the window solar component helped lower the annual building heating load by 650 MW h. Internal loads (lighting and office equipment) and part load operations of fans and pumps also played a significant role in the overall building energy efficiency. This paper presents the work, its findings and energy efficiency implications

  18. The Dossier Green Office. The most sustainable industrial building in the Netherlands; Het Dossier Groen Kantoor. Het duurzaamste bedrijfsgebouw van Nederland

    Energy Technology Data Exchange (ETDEWEB)

    Verdonk, A.

    2011-03-25

    About forty houses competed for the title of Most sustainable Industrial building Netherlands 2011, an initiative of a Dutch radio program ('Vroege Vogels') and the magazine De Ingenieur (The Engineer). The jury selected the renovated over one hundred years old water tower with newly built pavilion in Bussum as the winner. Besides the winner attention was also paid to innovative concepts applied in other buildings, including the office of Rijkswaterstaat Terneuzen, the Vomar Voordeelmarkt in Heerhugowaard, The Christiaan Huygens College, Eindhoven, the new Administration Centre of the Rabobank in Utrecht, and the office of the district water board Rivierenland Tiel. [Dutch] Zo'n veertig panden streden om de titel Duurzaamste Bedrijfsgebouw van Nederland 2011, een initiatief van het VARA-programma Vroege Vogels en De Ingenieur. De jury wees de gerenoveerde, ruim honderd jaar oude watertoren met nieuw aangebouwd paviljoen in Bussum aan als winnaar. Naast de winnaar wordt ook aandacht besteed aan de toegepaste innovatieve concepten in enkele andere gebouwen. Onder meer het kantoor van de Rijkswaterstaat in Terneuzen, de Vomar Voordeelmarkt in Heerhugowaard, Het Christiaan Huygens College in Eindhoven, het nieuwe Bestuurscentrum van de Rabobank in Utrecht, en het kantoor van Waterschap Rivierenland in Tiel.

  19. PhoneSat: Ground Testing of a Phone-Based Prototype Bus

    Science.gov (United States)

    Felix, Carmen; Howard, Benjamin; Reyes, Matthew; Snarskiy, Fedor; Hickman, Ryan; Boshuizen, Christopher; Marshall, William

    2010-01-01

    Most of the key capabilities that are requisite of a satellite bus are housed in today's smart phones. PhoneSat refers to an initiative to build a ground-based prototype vehicle that could all the basic functionality of a satellite, including attitude control, using a smart Phone as its central hardware. All components used were also low cost Commercial off the Shelf (COTS). In summer 2009, an initial prototype was created using the LEGO Mindstorm toolkit demonstrating simple attitude control. Here we report on a follow up initiative to design, build and test a vehicle based on the Google s smart phone Nexus One. The report includes results from initial thermal-vacuum chamber tests and low altitude sub-orbital rocket flights which show that, at least for short durations, the Nexus One phone is able to withstand key aspects of the space environment without failure. We compare the sensor data from the Phone's accelerometers and magnetometers with that of an external microelectronic inertial measurement unit.

  20. 75 FR 20833 - Building Energy Codes

    Science.gov (United States)

    2010-04-21

    ...-0012] Building Energy Codes AGENCY: Office of Energy Efficiency and Renewable Energy, Department of... the current model building energy codes or their equivalent. DOE is interested in better understanding... codes, Standard 90.1-2007, Energy Standard for Buildings Except Low-Rise Residential Buildings (or...

  1. Evaluation and optimisation of office buildings with near-surface geothermal energy for heating and cooling; Evaluierung und Optimierung von Buerogebaeuden mit oberflaechennaher Geothermie zum Heizen und Kuehlen

    Energy Technology Data Exchange (ETDEWEB)

    Bockelmann, Franziska; Kipry, Herdis; Fisch, M. Norbert [Technische Univ. Braunschweig (Germany). Inst. fuer Gebaeude- und Solartechnik

    2012-10-16

    In line with the research project WKSP - Heat and cold storage in the foundation area of office buildings (FKZ 0327364A), the Institute of Building Services and Energy Design of the Technical University Braunschweig (Braunschweig, Federal Republic of Germany) investigated the energy efficiency and thermal comfort of trend-setting office buildings in the practice. The objective was to gain validated knowledge on and to document the real performance of buildings with respect to energy consumption, user comfort and operation. In the majority of investigated plants, first of all mistakes were analysed and remedied so that a regular operation could be implemented. Subsequently, optimisation measures with respect to an efficient mode of operation of the geothermal energy storage system in the heating and cooling method were implemented. If the geothermal reservoir is laid out appropriately and operated correctly, the possible energy cost savings as well as the reductions of the CO{sub 2} emissions are significant due to the utilization of geothermal energy storage systems in comparison to heating and cooling systems. Increasing energy prices will further enhance the economic profitability of the application of the geothermal probe plants and energy pile plants.

  2. Commercial building energy use in six cities in Southern China

    International Nuclear Information System (INIS)

    Xu, Peng; Huang, Joe; Shen, Pengyuan; Ma, Xiaowen; Gao, Xuefei; Xu, Qiaolin; Jiang, Han; Xiang, Yong

    2013-01-01

    With China’s continuing economic growth, the percentage of government offices and large commercial buildings has increased tremendously; thus, the impact of their energy usage has grown drastically. In this survey, a database with more than 400 buildings was created and analyzed. We researched energy consumption by region, building type, building size and vintage, and we determined the total energy use and performed end use breakdowns of typical buildings in six cities in southern China. The statistical analysis shows that, on average, the annual building electricity use ranged from 50 to 100 kW h/m 2 for office buildings, 120 to 250 kW h/m 2 for shopping malls and hotels, and below 40 kW h/m 2 for education facilities. Building size has no direct correlation with building energy intensity. Although modern commercial buildings built in the 1990s and 2000s did not use more energy on average than buildings built previously, the highest electricity intensive modern buildings used much more energy than those built prior to 1990. Commercial buildings in China used less energy than buildings in equivalent weather locations in the US and about the same amount of energy as buildings in India. However, commercial buildings in China provide comparatively less thermal comfort than buildings in comparable US climates. - Highlights: ► The worst modern buildings use more energy than the worst old buildings. ► Government office buildings did not use more energy than private office buildings. ► Commercial buildings in China use less energy than buildings in the US. ► Modern commercial buildings don't use more energy than old buildings.

  3. Real-Time Occupant Based Plug-in Device Control Using ICT in Office Buildings

    Directory of Open Access Journals (Sweden)

    Woo-Bin Bae

    2016-03-01

    Full Text Available The purpose of this study is to reduce the unnecessary plug loads used by computers, monitors, and computer peripheral devices, all of which account for more than 95% of the entire plug loads of an office building. To this end, an occupant-based plug-in device control (OBC-P software was developed. The OBC-P software collects real-time information about the presence or absence of occupants who are connected to the access point through the Wifi and controls the power of monitors or computers, while a standby power off device controls computer peripheral devices. To measure the plug load saving of the occupant-based plug-in device control, an experiment was conducted, targeting 10 occupants of three research labs of the graduate school, for two weeks. The experiment results showed that it could save the plug loads of monitors and computer peripheral devices by 15% in the Awake mode, and by 26% in the Sleep mode.

  4. Experimental and CFD modelling for thermal comfort and CO2 concentration in office building

    Science.gov (United States)

    Kabrein, H.; Hariri, A.; Leman, A. M.; Yusof, M. Z. M.; Afandi, A.

    2017-09-01

    Computational fluid dynamic CFD was used for simulating air flow, indoor air distribution and contamination concentration. Gases pollution and thermal discomfort affected occupational health and productivity of work place. The main objectives of this study are to investigate the impact of air change rate in CO2 concentration and to estimate the profile of CO2 concentration in the offices building. The thermal comfort and gases contamination are investigated by numerical analysis CFD which was validated by experiment. Thus the air temperature, air velocity and CO2 concentration were measured at several points in the chamber with four occupants. Comparing between experimental and numerical results showed good agreement. In addition, the CO2 concentration around human recorded high, compared to the other area. Moreover, the thermal comfort in this study is within the ASHRAE standard 55-2004.

  5. Changes in respiratory and non-respiratory symptoms in occupants of a large office building over a period of moisture damage remediation attempts

    Science.gov (United States)

    Cho, Sook Ja; White, Sandra K.; Cox-Ganser, Jean M.

    2018-01-01

    There is limited information on the natural history of building occupants’ health in relation to attempts to remediate moisture damage. We examined changes in respiratory and non-respiratory symptoms in 1,175 office building occupants over seven years with multiple remediation attempts. During each of four surveys, we categorized participants using a severity score: 0 = asymptomatic; 1 = mild, symptomatic in the last 12 months, but not frequently in the last 4 weeks; 2 = severe, symptomatic at least once weekly in the last 4 weeks. Building-related symptoms were defined as improving away from the building. We used random intercept models adjusted for demographics, smoking, building tenure, and microbial exposures to estimate temporal changes in the odds of building-related symptoms or severity scores independent of the effect of microbial exposures. Trend analyses of combined mild/severe symptoms showed no changes in the odds of respiratory symptoms but significant improvement in non-respiratory symptoms over time. Separate analyses showed increases in the odds of severe respiratory symptoms (odds ratio/year = 1.15‒1.16, p-valuesremediation efforts might not be effective in improving occupants’ health. PMID:29324816

  6. The impact of energy labels and accessibility on office rents

    International Nuclear Information System (INIS)

    Kok, Nils; Jennen, Maarten

    2012-01-01

    Energy consumption in the commercial property sector offers an important opportunity for conserving resources. In this study, we evaluate the financial implications of two elements of “sustainability” – energy efficiency and accessibility – in the market for commercial real estate. An empirical analysis of some 1100 leasing transactions in the Netherlands over the 2005–2010 period shows that buildings designated as inefficient (with an EU energy performance certificate D or worse) command rental levels that are some 6.5 percent lower as compared to energy efficient, but otherwise similar buildings (labeled A, B or C). Furthermore, this study shows that office buildings in multi-functional areas, with access to public transport and facilities, achieve rental premiums over mono-functional office districts. For policymakers, the results documented in this paper provide an indication on the effectiveness of the EU energy performance certificate as a market signal in the commercial property sector. The findings documented here are also relevant for investors in European office markets, as the importance of energy efficiency and locational diversification is bound to increase following stricter environmental regulation and changing tenant preferences. - Highlights: ► Built environment plays important role in reduction of greenhouse gas emissions. ► Energy certification of buildings may increase transparency and awareness. ► Tenants pay lower rent for less efficient commercial office buildings. ► Accessibility important determinant of commercial office rents.

  7. Application of building system in prototype house building in a sustainable community; Aplicacion de un sistema constructivo innovador en uan vivienda prototipo de una comunidad ecologica sustentable

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Chavez, J. R.

    2004-07-01

    This work presents a prototype house built in a typical rural community of Mexico, based on the application of innovative building system and materials, integrated with bioclimatic design principles and sustainable technologies. The objectives of this project are aimed at reducing construction costs whilst providing suitable indoor thermal comfort conditions for the occupants and high levels of self-sufficiency in energy, mainly electricity and gas L. P.; and of natural resources, such as water. Results have shown that the application of this approach is a promising alternative to reduce construction costs of housing whilst providing suitable indoor thermal comfort conditions for occupants, and improving their economy and quality of living as well as the environment of the region. This approach can also be applied to promote a beneficial multiple effect in the country, to reduce the high housing deficit, whilst reducing the severe environmental damage, meant to effectively promote sustainability for the existing and new generation of the new millennium. (Author)

  8. The characteristics of purpose built offices in Malaysia: a review of issues

    OpenAIRE

    Mohd Safian, Edie Ezwan; Bagdad, Mariati; Nawawi, Abdul Hadi

    2011-01-01

    The development of purpose-built office market in Malaysia is basically determined by a supply-demand market. Since the purpose built office market in Malaysia has shown positive developments and increasing level of competitiveness, many building and locational characteristics have emerged and become important during the process of assessment of the office property involving property market appraisal and building performance evaluation. With these characteristics, property market participants...

  9. Relatively Inexpensive Rapid Prototyping of Small Parts

    Science.gov (United States)

    Swan, Scott A.

    2003-01-01

    Parts with complex three-dimensional shapes and with dimensions up to 8 by 8 by 10 in. (20.3 by 20.3 by 25.4 cm) can be made as unitary pieces of a room-temperature-curing polymer, with relatively little investment in time and money, by a process now in use at Johnson Space Center. The process is one of a growing number of processes and techniques that are known collectively as the art of rapid prototyping. The main advantages of this process over other rapid-prototyping processes are greater speed and lower cost: There is no need to make paper drawings and take them to a shop for fabrication, and thus no need for the attendant paperwork and organizational delays. Instead, molds for desired parts are made automatically on a machine that is guided by data from a computer-aided design (CAD) system and can reside in an engineering office.

  10. Digital Microdroplet Ejection Technology-Based Heterogeneous Objects Prototyping

    Science.gov (United States)

    Yang, Jiquan; Feng, Chunmei; Yang, Jianfei; Zhu, Liya; Guo, Aiqing

    2016-01-01

    An integrate fabrication framework is presented to build heterogeneous objects (HEO) using digital microdroplets injecting technology and rapid prototyping. The heterogeneous materials part design and manufacturing method in structure and material was used to change the traditional process. The net node method was used for digital modeling that can configure multimaterials in time. The relationship of material, color, and jetting nozzle was built. The main important contributions are to combine the structure, material, and visualization in one process and give the digital model for manufacture. From the given model, it is concluded that the method is effective for HEO. Using microdroplet rapid prototyping and the model given in the paper HEO could be gotten basically. The model could be used in 3D biomanufacturing. PMID:26981110

  11. Digital Microdroplet Ejection Technology-Based Heterogeneous Objects Prototyping

    Directory of Open Access Journals (Sweden)

    Na Li

    2016-01-01

    Full Text Available An integrate fabrication framework is presented to build heterogeneous objects (HEO using digital microdroplets injecting technology and rapid prototyping. The heterogeneous materials part design and manufacturing method in structure and material was used to change the traditional process. The net node method was used for digital modeling that can configure multimaterials in time. The relationship of material, color, and jetting nozzle was built. The main important contributions are to combine the structure, material, and visualization in one process and give the digital model for manufacture. From the given model, it is concluded that the method is effective for HEO. Using microdroplet rapid prototyping and the model given in the paper HEO could be gotten basically. The model could be used in 3D biomanufacturing.

  12. Digital Microdroplet Ejection Technology-Based Heterogeneous Objects Prototyping.

    Science.gov (United States)

    Li, Na; Yang, Jiquan; Feng, Chunmei; Yang, Jianfei; Zhu, Liya; Guo, Aiqing

    2016-01-01

    An integrate fabrication framework is presented to build heterogeneous objects (HEO) using digital microdroplets injecting technology and rapid prototyping. The heterogeneous materials part design and manufacturing method in structure and material was used to change the traditional process. The net node method was used for digital modeling that can configure multimaterials in time. The relationship of material, color, and jetting nozzle was built. The main important contributions are to combine the structure, material, and visualization in one process and give the digital model for manufacture. From the given model, it is concluded that the method is effective for HEO. Using microdroplet rapid prototyping and the model given in the paper HEO could be gotten basically. The model could be used in 3D biomanufacturing.

  13. Office Courtesy: Diferensiasi pada Komunikasi Organisasi

    OpenAIRE

    Yunus, Ulani

    2012-01-01

    Office etiquette or office courtesy is a procedure in a person with association or persons outside the organization. Etiquette teaches us to maintain good relations with the person / party. Etiquette becomes an inherent part of an organization because etiquette is not just a tool to assess an appropriate or inappropriate actions of members of the organization, but also the adhesive in the activities of a business transaction; that office image courtesy instrumental in building the organizatio...

  14. Commercial Building Energy Saver: An energy retrofit analysis toolkit

    International Nuclear Information System (INIS)

    Hong, Tianzhen; Piette, Mary Ann; Chen, Yixing; Lee, Sang Hoon; Taylor-Lange, Sarah C.; Zhang, Rongpeng; Sun, Kaiyu; Price, Phillip

    2015-01-01

    Highlights: • Commercial Building Energy Saver is a powerful toolkit for energy retrofit analysis. • CBES provides benchmarking, load shape analysis, and model-based retrofit assessment. • CBES covers 7 building types, 6 vintages, 16 climates, and 100 energy measures. • CBES includes a web app, API, and a database of energy efficiency performance. • CBES API can be extended and integrated with third party energy software tools. - Abstract: Small commercial buildings in the United States consume 47% of the total primary energy of the buildings sector. Retrofitting small and medium commercial buildings poses a huge challenge for owners because they usually lack the expertise and resources to identify and evaluate cost-effective energy retrofit strategies. This paper presents the Commercial Building Energy Saver (CBES), an energy retrofit analysis toolkit, which calculates the energy use of a building, identifies and evaluates retrofit measures in terms of energy savings, energy cost savings and payback. The CBES Toolkit includes a web app (APP) for end users and the CBES Application Programming Interface (API) for integrating CBES with other energy software tools. The toolkit provides a rich set of features including: (1) Energy Benchmarking providing an Energy Star score, (2) Load Shape Analysis to identify potential building operation improvements, (3) Preliminary Retrofit Analysis which uses a custom developed pre-simulated database and, (4) Detailed Retrofit Analysis which utilizes real-time EnergyPlus simulations. CBES includes 100 configurable energy conservation measures (ECMs) that encompass IAQ, technical performance and cost data, for assessing 7 different prototype buildings in 16 climate zones in California and 6 vintages. A case study of a small office building demonstrates the use of the toolkit for retrofit analysis. The development of CBES provides a new contribution to the field by providing a straightforward and uncomplicated decision

  15. Design decisions in the front office - back office issue : A Study of Trade-offs in the Financial Services Sector

    NARCIS (Netherlands)

    Zomerdijk, L.G.

    2005-01-01

    This dissertation presents the results of a research study that involved the development of a framework that provides insight in and so supports design decisions regarding front office and back office activities in service delivery processes. Building on the evidence from five case studies in the

  16. An office building of Paris city air-conditioned by an aquifer-source heat pump; Un immeuble parisien climatise par une thermofrigopompe sur nappe phreatique

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2003-09-01

    A 7000 m{sup 2} office building of Paris (France) is equipped with an aquifer-source heat pump for the space heating and cooling. This choice allows to save 28400 euros of heating/cooling expenses each year with respect to other solutions. The equipment ensures also the production of hot and chilled water and the calories recovered from the refrigeration system are used to supply the space heating needs of the building. This paper describes the equipments (heat pump, heat exchangers, ventilation-convection systems), the centralized control system and the cost-benefit aspects. (J.S.)

  17. The prototype triggerless data acquisition of the PANDA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Milan; Reiter, Simon; Lange, Soeren; Kuehn, Wolfgang [II. Physikalisches Institut, Giessen Univ. (Germany); Collaboration: PANDA-Collaboration

    2016-07-01

    The PANDA detector will operate with a very high interaction rate of up to 20 MHz, in a free streaming mode without hardware trigger. Data filtering will be performed by complete online event reconstruction with a highly parallelized farm of FPGAs as first level and on a farm of GPUs or PCs as a second level. The requirement is a background reduction by a factor of >1000. A prototype trigger-less data acquisition (PTDAQ) system for the detector validation measurements comprises free streaming and synchronization readout, for event building and filtering has been developed. A first in beam environment test was performed at the Mainzer Mikrotron, reading out the barrel electromagnetic calorimeter prototype (Proto120).

  18. Creating Office Spaces in the Mediterranean. The importance of well-being, health and performance of office users

    Directory of Open Access Journals (Sweden)

    C. Mateo-Cecilia

    2018-04-01

    Full Text Available Recent research has studied the influence of office buildings indoor environment quality (IEQ on employees’ well-being, health and performance. However, it seems that it has not been explicitly explored what are the appropriate environmental conditions to different work patterns that coexist in these spaces. This paper presents results of an empirical research, based on the synchronized measurements of different IEQ parameters (i.e., noise, lighting and temperature, and well-being, health and performance of 71 employees in twelve office spaces in the Valencian Community along three periods, considering winter and summer conditions. Findings of the first winter period data, suggest the existence of different ideal parameters for different levels of task complexity (one of the dimensions that characterizes work patterns in the Mediterranean climate; and open new avenues of research to build up a specific Smart and Sustainable Offices (SSO model and further systemic design-support tools.

  19. Office Courtesy: Diferensiasi pada Komunikasi Organisasi

    Directory of Open Access Journals (Sweden)

    Ulani Yunus

    2012-04-01

    Full Text Available Office etiquette or office courtesy is a procedure in a person with association or persons outside the organization. Etiquette teaches us to maintain good relations with the person / party. Etiquette becomes an inherent part of an organization because etiquette is not just a tool to assess an appropriate or inappropriate actions of members of the organization, but also the adhesive in the activities of a business transaction; that office image courtesy instrumental in building the organization. Through the courtesy of its contextual office applied through: adjustments to the organizational culture, attitudes toward seniors, standardization attitude towards the stakeholders. Thus, a typical office courtesy can be a differentiation of an organization.  

  20. Buildings Interoperability Landscape

    Energy Technology Data Exchange (ETDEWEB)

    Hardin, Dave [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stephan, Eric G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wang, Weimin [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Corbin, Charles D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Widergren, Steven E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-12-31

    Through its Building Technologies Office (BTO), the United States Department of Energy’s Office of Energy Efficiency and Renewable Energy (DOE-EERE) is sponsoring an effort to advance interoperability for the integration of intelligent buildings equipment and automation systems, understanding the importance of integration frameworks and product ecosystems to this cause. This is important to BTO’s mission to enhance energy efficiency and save energy for economic and environmental purposes. For connected buildings ecosystems of products and services from various manufacturers to flourish, the ICT aspects of the equipment need to integrate and operate simply and reliably. Within the concepts of interoperability lie the specification, development, and certification of equipment with standards-based interfaces that connect and work. Beyond this, a healthy community of stakeholders that contribute to and use interoperability work products must be developed. On May 1, 2014, the DOE convened a technical meeting to take stock of the current state of interoperability of connected equipment and systems in buildings. Several insights from that meeting helped facilitate a draft description of the landscape of interoperability for connected buildings, which focuses mainly on small and medium commercial buildings. This document revises the February 2015 landscape document to address reviewer comments, incorporate important insights from the Buildings Interoperability Vision technical meeting, and capture thoughts from that meeting about the topics to be addressed in a buildings interoperability vision. In particular, greater attention is paid to the state of information modeling in buildings and the great potential for near-term benefits in this area from progress and community alignment.

  1. About the Better Buildings Neighborhood Program

    Energy Technology Data Exchange (ETDEWEB)

    None

    2011-12-16

    The Better Buildings Neighborhood Program is part of the Better Buildings Initiative—a program within the U.S. Department of Energy's (DOE's) Office of Energy Efficiency and Renewable Energy (EERE) that is lowering barriers to energy efficiency in buildings.

  2. TaskMaster: a prototype graphical user interface to a schedule optimization model

    OpenAIRE

    Banham, Stephen R.

    1990-01-01

    Approved for public release, distribution is unlimited This thesis investigates the use of current graphical interface techniques to build more effective computer-user interfaces to Operations Research (OR) schedule optimization models. The design is directed at the scheduling decision maker who possesses limited OR experience. The feasibility and validity of building an interface for this kind of user is demonstrated in the development of a prototype graphical user interface called TaskMa...

  3. Smart and Sustainable Offices (SSO: Showcasing a holistic approach to realise the next generation offices

    Directory of Open Access Journals (Sweden)

    A. Cobaleda Cordero

    2018-01-01

    Full Text Available The Smart Sustainable Offices project (SSO is a product of years of research with large sets of data collected from more than 30 office buildings in Switzerland, Sweden, and Spain. Based on scientific evidence, the concept of SSO, initially conceived as a research plan to address the interdependencies between office users and their working environment in a European context, is now used as a qualitative and quantitative mixed method approach for office diagnosis and ideation. At the current stage, the SSO methodology aims to implement a new paradigm of user-oriented, lower carbon footprint and resilient office design solutions. The main strategy is articulated around the “office DNA” of every organisation, decoded as a compound of work patterns, operational and individual needs, and their potential to define design criteria. The practical application of SSO and its tentative findings exemplified through three pilot test office-demonstrators are described in this paper.

  4. Annual Energy Savings and Thermal Comfort of Autonomously Heated and Cooled Office Chairs

    Energy Technology Data Exchange (ETDEWEB)

    Carmichael, Scott [National Renewable Energy Lab. (NREL), Golden, CO (United States); Booten, Chuck [National Renewable Energy Lab. (NREL), Golden, CO (United States); Robertson, Joseph [National Renewable Energy Lab. (NREL), Golden, CO (United States); Chin, Justin [National Renewable Energy Lab. (NREL), Golden, CO (United States); Christensen, Dane [National Renewable Energy Lab. (NREL), Golden, CO (United States); Pless, Jacquelyn [National Renewable Energy Lab. (NREL), Golden, CO (United States); Arent, Doug [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-07-01

    Energy use in offices buildings is largely driven by air conditioning demands. But the optimal temperature is not the same for all building occupants, leading to the infamous thermostat war. And many occupants have independently overcome building comfort weaknesses with their own space heaters or fans. NREL tested is a customized office chair that automatically heats and cools the occupant along the seat and chair back according to the occupants' personal preferences. This product is shown to deliver markedly better comfort at room temperatures well above typical office cooling setpoints. Experimental subjects reported satisfaction in these elevated air temperatures, partly because the chair's cooling effect was tuned to their own individual needs. Simulation of the chair in office buildings around the U.S. shows that energy can be saved everywhere, with impacts varying due to the climate. Total building HVAC energy savings exceeded 10% in hot-dry climate zones. Due to high product cost, simple payback for the chair we studied is beyond the expected chair life. We then understood the need to establish cost-performance targets for comfort delivery packages. NREL derived several hypothetical energy/cost/comfort targets for personal comfort product systems. In some climate regions around the U.S., these show the potential for office building HVAC energy savings in excess of 20%. This report documents this research, providing an overview of the research team's methods and results while also identifying areas for future research building upon the findings.

  5. Architectural prototyping

    DEFF Research Database (Denmark)

    Bardram, Jakob Eyvind; Christensen, Henrik Bærbak; Hansen, Klaus Marius

    2004-01-01

    A major part of software architecture design is learning how specific architectural designs balance the concerns of stakeholders. We explore the notion of "architectural prototypes", correspondingly architectural prototyping, as a means of using executable prototypes to investigate stakeholders...

  6. Rapid prototyping in order to improve building performance simulation for detailed design support

    NARCIS (Netherlands)

    Hopfe, C.J.; Hensen, J.L.M.; Stankov, P.

    2006-01-01

    Building performance simulation (BPS) is a powerful tool to support building and system designers in emulating how orientation, building type, HVAC system etc. interacts the overall building performance. Currently BPS is used only for code compliance in the detailed design, neither to make informed

  7. Thermo Active Building Systems – Using Building Mass To Heat and Cool

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.

    2014-01-01

    , Austria, Netherlands, etc.), this type of system has been installed in a significant number of new office buildings since the late 1990s. The trend is spreading to other parts of the world (the rest of Europe, North America and Asia). Thermo active building systems (TABS) are primarily used for cooling...

  8. An analysis of buildings-related energy use in manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Niefer, M.J.; Ashton, W.B.

    1997-04-01

    This report presents research by the Pacific Northwest National Laboratory (PNNL) to develop improved estimates of buildings-related energy use in US manufacturing facilities. The research was supported by the Office of Building Technology, State and Community Programs (BTS), Office of Energy Efficiency and Renewable Energy (EERE), US Department of Energy (DOE). The research scope includes only space conditioning and lighting end uses. In addition, this study also estimates the energy savings potential for application of selected commercial buildings technologies being developed by the BTS office to manufacturing and other industrial process facilities. 17 refs., 2 figs., 19 tabs.

  9. A progress report of the switch-based data acquisition system prototype project and the application of switches from industry to high-energy physics event building

    International Nuclear Information System (INIS)

    Barsotti, E.; Booth, A.; Bowden, M.; Swoboda, C.

    1990-01-01

    A prototype of a data acquisition system based on a new scalable, highly-parallel, open-system architecture is being developed at Fermilab. The major component of the new architecture, the parallel event builder, is based on a telecommunications industry technique used in the implementation of switching systems, a barrel-shift switch. The architecture is scalable both in the expandability of the number of input channels and in the throughput of the system. Because of its scalability, the system is well suited for low to high-rate experiments, test beams and all SSC detectors. The architecture is open in that as new technologies are developed and made into commercial products (e.g., arrays of processors and workstations and standard data links), these new products can be easily integrated into the system with minimal system modifications and no modifications to the system's basic architecture. Scalability and openness should guarantee that the data acquisition system does not become obsolete during the lifetime of the experiment. The paper first gives a description of the architecture and the prototype project and then details both the prototype project's software and hardware status including details of some architecture simulation studies. Suggestions for future R and D work on the new data acquisition system architecture are then described. The paper concludes by examining interconnection networks from industry and their application to event building and to other areas of high-energy physics data acquisition systems

  10. Digital Microdroplet Ejection Technology-Based Heterogeneous Objects Prototyping

    OpenAIRE

    Li, Na; Yang, Jiquan; Feng, Chunmei; Yang, Jianfei; Zhu, Liya; Guo, Aiqing

    2016-01-01

    An integrate fabrication framework is presented to build heterogeneous objects (HEO) using digital microdroplets injecting technology and rapid prototyping. The heterogeneous materials part design and manufacturing method in structure and material was used to change the traditional process. The net node method was used for digital modeling that can configure multimaterials in time. The relationship of material, color, and jetting nozzle was built. The main important contributions are to combi...

  11. Experimental and analytical studies of a deeply embedded reactor building model considering soil-building interaction. Pt. 1

    International Nuclear Information System (INIS)

    Tanaka, H.; Ohta, T.; Uchiyama, S.

    1979-01-01

    The purpose of this paper is to describe the dynamic characteristics of a deeply embedded reactor building model derived from experimental and analytical studies which considers soil-building interaction behaviour. The model building is made of reinforced concrete. It has two stories above ground level and a basement, resting on sandy gravel layer at a depth of 3 meters. The backfill around the building was made to ground level. The model building is simplified and reduced to about one-fifteenth (1/15) of the prototype. It has bearing wall system for the basement and the first story, and frame system for the second. (orig.)

  12. HSIP New Mexico State Government Buildings

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This dataset includes buildings occupied by the headquarters of cabinet level state government executive departments, legislative offices buildings outside of the...

  13. Gender differences in public office workers' satisfaction, subjective symptoms and musculoskeletal complaints in workplace and office environments.

    Science.gov (United States)

    Lee, Sangbok; Park, Myoung Hwan; Jeong, Byung Yong

    2018-06-01

    This study investigates differences between male and female public office workers' satisfaction levels, sick building syndrome (SBS) symptoms and musculoskeletal disorder (MSD) complaints in workplace and office environments. Questionnaire surveys were performed in 30 offices from 15 public institutions. Male and female workers of the same age were coupled and selected from each office, gathering a total of 120 male and 120 female subjects. The results show that differences exist between genders in noise and lighting satisfaction levels, SBS-related symptoms (eye, nose, skin) and MSD complaints of hand/wrist/finger, while there is no difference in overall satisfaction level of office environments. The study also suggests that office design for public office workers should take into account gender differences in preventing MSDs and also SBS. The findings of this study are expected to serve as basic data for designing effective public office environments.

  14. After-hours power status of office equipment and energy use of miscellaneous plug-load equipment

    Energy Technology Data Exchange (ETDEWEB)

    Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.; Brown, Richard E.; Pinckard, Marageret J.; Busch, John F.

    2004-05-27

    This research was conducted in support of two branches of the EPA ENERGY STAR program, whose overall goal is to reduce, through voluntary market-based means, the amount of carbon dioxide emitted in the U.S. The primary objective was to collect data for the ENERGY STAR Office Equipment program on the after-hours power state of computers, monitors, printers, copiers, scanners, fax machines, and multi-function devices. We also collected data for the ENERGY STAR Commercial Buildings branch on the types and amounts of miscellaneous plug-load equipment, a significant and growing end use that is not usually accounted for by building energy managers. For most types of miscellaneous equipment, we also estimated typical unit energy consumption in order to estimate total energy consumption of the miscellaneous devices within our sample. This data set is the first of its kind that we know of, and is an important first step in characterizing miscellaneous plug loads in commercial buildings. The main purpose of this study is to supplement and update previous data we collected on the extent to which electronic office equipment is turned off or automatically enters a low power state when not in active use. In addition, it provides data on numbers and types of office equipment, and helps identify trends in office equipment usage patterns. These data improve our estimates of typical unit energy consumption and savings for each equipment type, and enables the ENERGY STAR Office Equipment program to focus future effort on products with the highest energy savings potential. This study expands our previous sample of office buildings in California and Washington DC to include education and health care facilities, and buildings in other states. We report data from sixteen commercial buildings in California, Georgia, and Pennsylvania: four education buildings, two medical buildings, two large offices (> 500 employees each), three medium offices (50-500 employees each), and five small

  15. Prototype dining hall energy efficiency study

    Energy Technology Data Exchange (ETDEWEB)

    Mazzucchi, R.P.; Bailey, S.A.; Zimmerman, P.W.

    1988-06-01

    The energy consumption of food service facilities is among the highest of any commercial building type, owing to the special requirements for food preparation, sanitation, and ventilation. Consequently, the US Air Force Engineering and Services Center (AFESC) contracted with Pacific Northwest Laboratory (PNL) to collect and analyze end-use energy consumption data for a prototypical dining hall and make specific recommendations on cost-effective energy conservation options. This information will be used to establish or update criteria for dining hall designs and retrofits as appropriate. 6 refs., 21 figs., 23 tabs.

  16. Airflow and radon transport modeling in four large buildings

    International Nuclear Information System (INIS)

    Fan, J.B.; Persily, A.K.

    1995-01-01

    Computer simulations of multizone airflow and contaminant transport were performed in four large buildings using the program CONTAM88. This paper describes the physical characteristics of the buildings and their idealizations as multizone building airflow systems. These buildings include a twelve-story multifamily residential building, a five-story mechanically ventilated office building with an atrium, a seven-story mechanically ventilated office building with an underground parking garage, and a one-story school building. The air change rates and interzonal airflows of these buildings are predicted for a range of wind speeds, indoor-outdoor temperature differences, and percentages of outdoor air intake in the supply air Simulations of radon transport were also performed in the buildings to investigate the effects of indoor-outdoor temperature difference and wind speed on indoor radon concentrations

  17. Sustainable newly built UPC office in Leeuwarden, Netherlands. Use of surface water for cooling call centre and office building; Duurzame nieuwbouw UPC Leeuwarden. Oppervlaktewater voor koeling callcenter en kantoor ingezet

    Energy Technology Data Exchange (ETDEWEB)

    Groot-D' hondt, E. [Wolter en Dros, Amersfoort (Netherlands)

    2010-10-15

    The municipality of Leeuwarden, Netherlands, and the cable company UPC Netherlands signed contracts for the construction of the UPC headquarters in Leeuwarden, March 2010. The building of the 'greenest' Green Office of the Netherlands, started in June 2010 and is expected to be finalized the end of 2011. Use is made of surface water, rain, heat and cold storage in combination with a heat pump and low temperature systems, such as climate ceilings and floor heating, green roofs, natural insulation, and photovoltaic cells. [Dutch] De gemeente Leeuwarden en UPC Nederland ondertekenden 17 maart 2010 de contracten voor de nieuwbouw van het UPC-hoofdkantoor in Leeuwarden. De bouw van het 'groenste' Green Office van Nederland, startte in juni 2010 en wordt naar verwachting eind 2011 opgeleverd. Er wordt gebruik gemaakt van oppervlaktewater, regenwater, warmte- en koudeopslag in combinatie met een warmtepomp en lage temperatuursystemen, zoals klimaatplafonds en vloerverwarming, groene daken , natuurlijke isolatie, en photovoltaische cellen.

  18. Video prototype of the interactive operating theatre

    DEFF Research Database (Denmark)

    2004-01-01

    Building capture and access (C&A) applications for use in the operation theatre differs greatly from C&A applications built to support other settings e.g. meeting rooms or classrooms. Based on field studies of surgical operations, this paper explores how to design C&A applications for the operation...... theatre. Based on the findings from our field work, we have built the ActiveTheatre, a C&A prototype. ActiveTheatre is built to support collaboration in and around the operating theatre, to capture events instead of automatically capturing eve- rything, and to be integrated with existing applications...... already present in the operation theatre. The ActiveTheatre prototype has been developed in close co- operation with surgeons and nurses at a local hospital. The work on the proto- type and our initial evaluations have provided an insight into how to design, capture and access applications that are going...

  19. 43 CFR 8.6 - Buildings.

    Science.gov (United States)

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Buildings. 8.6 Section 8.6 Public Lands: Interior Office of the Secretary of the Interior JOINT POLICIES OF THE DEPARTMENTS OF THE INTERIOR AND OF THE ARMY RELATIVE TO RESERVOIR PROJECT LANDS § 8.6 Buildings. Buildings for human occupancy as well as...

  20. Design/build: A Relevant Pedagogy for Architecture Education

    Directory of Open Access Journals (Sweden)

    Olivier Chamel

    2016-12-01

    This paper will present a series of recent furniture design/build exercises where students designed and furniture and small building prototypes with limited reliance on drawings. We will discuss how subjects such as structures, material sourcing and construction detailing can be transposed from various courses and applied to design/build projects. We believe that a pedagogy based on physical experimentations could infuse energy throughout curricula no matter the course subject.

  1. Paper in architecture: Research by design, engineering and prototyping

    Directory of Open Access Journals (Sweden)

    Jerzy F. Latka

    2017-11-01

    in terms of architecture, its material properties were researched on a micro, meso and macro level. This research of the possible applications of paper in architecture was informed by two main research questions: What is paper and to what extent can it be used in architecture? What is the most suitable way to use paper in emergency architecture? To answer the first research question, fundamental and material research on paper and paper products had to be conducted. The composition of the material, production methods and properties of paper were researched. Then paper products with the potential to be used in architecture were examined. The history of the development of paper and its influence on civilisation helped the author gain a better understanding of the nature of this material, which we encounter in our lives every day. Research on objects for everyday use, furniture, pavilions and architecture realised in the last 150 years allowed the author to distinguish various types of paper design and paper architecture. Analysis of realised buildings in which paper products were used as structural elements and parts of the building envelope resulted in a wide array of possible solutions. Structural systems, types of connections between the various elements, impregnation methods and the functionalities and lifespan of different types of buildings were systematised. The knowledge thus collected allowed the author to conduct a further exploration of paper architecture in the form of designs and prototypes. To answer the second research question, the analysed case studies were translated into designs and prototypes of emergency shelters. During the research-by-design, engineering and prototyping phases, more than a dozen prototypes were built. The prototypes differed in terms of structural systems, used materials, connections between structural elements, impregnation methods, functionality and types of building. The three versions of the Transportable Emergency Cardboard

  2. Are Biophilic-Designed Site Office Buildings Linked to Health Benefits and High Performing Occupants?

    Directory of Open Access Journals (Sweden)

    Tonia Gray

    2014-11-01

    Full Text Available This paper discusses the first phase of a longitudinal study underway in Australia to ascertain the broad health benefits of specific types of biophilic design for workers in a building site office. A bespoke site design was formulated to include open plan workspace, natural lighting, ventilation, significant plants, prospect and views, recycled materials and use of non-synthetic materials. Initial data in the first three months was gathered from a series of demographic questions and from interviews and observations of site workers. Preliminary data indicates a strong positive effect from incorporating aspects of biophilic design to boost productivity, ameliorate stress, enhance well-being, foster a collaborative work environment and promote workplace satisfaction, thus contributing towards a high performance workspace. The longitudinal study spanning over two years will track human-plant interactions in a biophilic influenced space, whilst also assessing the concomitant cognitive, social, psychological and physical health benefits for workers.

  3. Associations between the Objectively Measured Office Environment and Workplace Step Count and Sitting Time: Cross-Sectional Analyses from the Active Buildings Study.

    Science.gov (United States)

    Fisher, Abi; Ucci, Marcella; Smith, Lee; Sawyer, Alexia; Spinney, Richard; Konstantatou, Marina; Marmot, Alexi

    2018-06-01

    office buildings to establish whether a specific office typology may yield more promising results.

  4. Bellanca building, Yellowknife : building envelope retrofit project

    Energy Technology Data Exchange (ETDEWEB)

    Rajewski, G. [A.D. Williams Engineering Inc., Edmonton, AB (Canada)

    2008-07-01

    The Bellanca building is a ten-story, commercial office building, located in Yellowknife, Northwest Territories. The owner was concerned about annual fuel consumption, relative to other buildings of similar size. Tenants reported cold drafts and some ice build-up had been reported in the past, on the exterior of the cladding. In addition, some water penetration had occurred during rainfall. This presentation provided background information on the Bellanca building and discussed a building envelope retrofit project. A.D. Williams was hired in late 2006 in order to provide an opinion on the present condition of the building envelope. This presentation described the site investigation and presented an interior and exterior review of the building. It also presented a thermographic survey in order to map thermal anomalies and establish trends. Following acceptance of the report on findings, one of five options was selected for further development. This included removal of existing cladding, exterior gypsum wallboard, fiberglass insulation and application of BASF Walltite CT foam, sheathing, rigid insulation, drainage plane and new cladding. The preliminary design was then presented. This paper also described the tender and award of the contract; construction phase; and substantial completion of the project. tabs, figs.

  5. Association of airborne moisture-indicating microorganisms withbuilding-related symptoms and water damage in 100 U.S. office buildings:Analyses of the U.S. EPA BASE data

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, Mark J.; Lei, Quanhong; Cozen, Myrna O.; Shendell, DerekG.; Macher, Janet M.; Tsai, Feng C.

    2003-10-01

    Metrics of culturable airborne microorganisms for either total organisms or suspected harmful subgroups have generally not been associated with symptoms among building occupants. However, the visible presence of moisture damage or mold in residences and other buildings has consistently been associated with respiratory symptoms and other health effects. This relationship is presumably caused by adverse but uncharacterized exposures to moisture-related microbiological growth. In order to assess this hypothesis, we studied relationships in U.S. office buildings between the prevalence of respiratory and irritant symptoms, the concentrations of airborne microorganisms that require moist surfaces on which to grow, and the presence of visible water damage. For these analyses we used data on buildings, indoor environments, and occupants collected from a representative sample of 100 U.S. office buildings in the U.S. Environmental Protection Agency's Building Assessment Survey and Evaluation (EPA BASE) study. We created 19 alternate metrics, using scales ranging from 3-10 units, that summarized the concentrations of airborne moisture-indicating microorganisms (AMIMOs) as indicators of moisture in buildings. Two were constructed to resemble a metric previously reported to be associated with lung function changes in building occupants; the others were based on another metric from the same group of Finnish researchers, concentration cutpoints from other studies, and professional judgment. We assessed three types of associations: between AMIMO metrics and symptoms in office workers, between evidence of water damage and symptoms, and between water damage and AMIMO metrics. We estimated (as odds ratios (ORs) with 95% confidence intervals) the unadjusted and adjusted associations between the 19 metrics and two types of weekly, work-related symptoms--lower respiratory and mucous membrane--using logistic regression models. Analyses used the original AMIMO metrics and were

  6. The occurrence of legionalla in hot water distribution systems of some Finnish apartment and office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Zacheus, O M; Kuittinen, M H; Martikainen, P J [National Public Health Institute, Dept. Environ. Hyg. and Toxicol., Kuopio (FI)

    1991-01-01

    A project concerning the effect of water temperature and water quality on the microbiology of hot water distribution systems in Finnish apartment and office buildings was started in 1989. Here we report preliminary results on the occurrence of legionella. Samples were taken from showerpipes and from hot water mains before and after calorifiers of 17 buildings. Water temperature in the showerpipes ranged from 39 to 55 deg. C. Water temperature before calorifiers ranged from 40 to 52 deg. C and after them from 39 to 59 deg. C. Water temperature did not explain well the occurrence of legionalla. Legionalla pneumophila was isolated from six systems. The isolates were serogroups 1, 5 and 6. Legionella concentrations in positive samples ranged from 100 to 350 000 CFU/l. Highest concentrations of legionalla were obtained from showerpipes and hot water mains before calorifiers. Four legionella positive distribution systems were decontaminated by raising the water temperature to 60-70 deg. C and cleaning taps and showerheads, and flushing them twice a day. The numbers of legionellas in the hot water mains fell below detection limit (50 CFU/l) and their numbers also decreased in showerpipes. Decontamination failed in some parts of the distribution systems where water temperature remained below 60 deg. C. (author) 26 refs.

  7. The Osseus platform: a prototype for advanced web-based distributed simulation

    Science.gov (United States)

    Franceschini, Derrick; Riecken, Mark

    2016-05-01

    Recent technological advances in web-based distributed computing and database technology have made possible a deeper and more transparent integration of some modeling and simulation applications. Despite these advances towards true integration of capabilities, disparate systems, architectures, and protocols will remain in the inventory for some time to come. These disparities present interoperability challenges for distributed modeling and simulation whether the application is training, experimentation, or analysis. Traditional approaches call for building gateways to bridge between disparate protocols and retaining interoperability specialists. Challenges in reconciling data models also persist. These challenges and their traditional mitigation approaches directly contribute to higher costs, schedule delays, and frustration for the end users. Osseus is a prototype software platform originally funded as a research project by the Defense Modeling & Simulation Coordination Office (DMSCO) to examine interoperability alternatives using modern, web-based technology and taking inspiration from the commercial sector. Osseus provides tools and services for nonexpert users to connect simulations, targeting the time and skillset needed to successfully connect disparate systems. The Osseus platform presents a web services interface to allow simulation applications to exchange data using modern techniques efficiently over Local or Wide Area Networks. Further, it provides Service Oriented Architecture capabilities such that finer granularity components such as individual models can contribute to simulation with minimal effort.

  8. Associations of indoor carbon dioxide concentrations, VOCS, environmental susceptibilities with mucous membrane and lower respiratory sick building syndrome symptoms in the BASE study: Analyses of the 100 building dataset

    Energy Technology Data Exchange (ETDEWEB)

    Apte, M.G.; Erdmann, C.A.

    2002-10-01

    Using the 100 office-building Building Assessment Survey and Evaluation (BASE) Study dataset, we performed multivariate logistic regression analyses to quantify the associations between indoor minus outdoor CO{sub 2} (dCO{sub 2}) concentrations and mucous membrane (MM) and lower respiratory system (Lresp) Sick Building Syndrome (SBS) symptoms, adjusting for age, sex, smoking status, presence of carpet in workspace, thermal exposure, relative humidity, and a marker for entrained automobile exhaust. Using principal components analysis we identified a number of possible sources of 73 measured volatile organic compounds in the office buildings, and assessed the impact of these VOCs on the probability of presenting the SBS symptoms. Additionally we included analysis adjusting for the risks for predisposition of having SBS symptoms associated with the allergic, asthmatic, and environmentally sensitive subpopulations within the office buildings. Adjusted odds ratios (ORs) for statistically significant, dose-dependant associations (p<0.05) for dry eyes, sore throat, nose/sinus congestion, and wheeze symptoms with 100-ppm increases in dCO{sub 2} ranged from 1.1 to 1.2. These results suggest that increases in the ventilation rates per person among typical office buildings will, on average significantly reduce the prevalence of several SBS symptoms, up to 80%, even when these buildings meet the existing ASHRAE ventilation standards for office buildings. VOC sources were observed to play an role in direct association with mucous membrane and lower respiratory irritation, and possibly to be indirectly involved in indoor chemical reactions with ozone that produce irritating compounds associated with SBS symptoms. O-xylene, possibly emitted from furniture coatings was associated with shortness of breath (OR at the maximum concentration = 8, p < 0.05). The environmental sensitivities of a large subset of the office building population add to the overall risk of SBS symptoms (ORs

  9. Thermal comfort in office buildings: Two case studies commented

    Energy Technology Data Exchange (ETDEWEB)

    Hens, Hugo S.L.C. [Laboratory of Building Physics, Department of Civil Engineering, K.U. Leuven, Kasteelpark Arenberg 40, B-3001 Leuven (Heverlee) (Belgium)

    2009-07-15

    Air conditioning in offices has become a current practice in North Western Europe. The main reasons for that are high internal loads, solar gains and increased comfort expectations. Hence, the move away from the naturally ventilated cellular office increased thermal comfort complaints. The paper presents two cases. In both the results of a comfort enquiry are compared with measurements. The enquiries gave numbers of dissatisfied at a PMV zero that were much higher than the standard PMV/PPD curve does. Measurements instead showed that in one of the two offices only comfort complaints could be expected in summer. But even then, the enquired severity of complaints could not be related to the measured data. Several hypotheses are forwarded to explain the results. Individuals interpret the -3 to +3 scale for thermal sensation differently, which has a direct impact on the number of dissatisfied. The standard curve further-on is a most significant mean of thousands of steady state comfort votes under well-controlled conditions while an on site enquiry involves much smaller numbers of people. These have a clear expectation: an improvement of comfort condition, thanks to the study. For that reason they may exaggerate their complaints when enquired. And finally, an alternative PMV versus PPD curve, published in literature, shows more people complaining at a given PMV than the standard curve forwards. (author)

  10. Building Energy Management Systems BEMS, German contribution to the IEA research projects Annex 16 and 17. Building Energy Management System BEMS; deutscher Beitrag zu den IEA-Forschungsvorhaben Annex 16 und 17

    Energy Technology Data Exchange (ETDEWEB)

    Bach, H.; Stephan, W.; Madjidi, M. (Univ. Stuttgart, IKE, Abt. HLK (Germany)); Brendel, T.; Schneider, A. (Ingenieurbuero Dr. Brendel, Frankfurt am Main (Germany)); Ast, H.; Kellner, H. (IFB, Dr. R. Braschel GmbH, Stuttgart (Germany))

    1991-01-01

    As part of the IEA project Annex 16 and 17 Germany carries out the project Building Energy Management Systems (BEMS). With digital control systems energetic and low-cost operation of space hvac systems can be attained. The project aims at abolishing impediments to efficient use of energy. Potential savings are shown for three examples: A conventional heating system for an office building, a VAV system (circulating air, heating, cooling, washer humidifcation) for an office building and VAV systems (FWRG, heating, cooling, steam humidification) for an office building in compact design. (BWI).

  11. Building Acoustics

    Science.gov (United States)

    Cowan, James

    This chapter summarizes and explains key concepts of building acoustics. These issues include the behavior of sound waves in rooms, the most commonly used rating systems for sound and sound control in buildings, the most common noise sources found in buildings, practical noise control methods for these sources, and the specific topic of office acoustics. Common noise issues for multi-dwelling units can be derived from most of the sections of this chapter. Books can be and have been written on each of these topics, so the purpose of this chapter is to summarize this information and provide appropriate resources for further exploration of each topic.

  12. A Comparative Cradle-to-Gate Life Cycle Assessment of Mid-Rise Office Building Construction Alternatives: Laminated Timber or Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    Raymond J. Cole

    2012-07-01

    Full Text Available The objective of this project was to quantify and compare the environmental impacts associated with alternative designs for a typical North American mid-rise office building. Two scenarios were considered; a traditional cast-in-place, reinforced concrete frame and a laminated timber hybrid design, which utilized engineered wood products (cross-laminated timber (CLT and glulam. The boundary of the quantitative analysis was cradle-to-construction site gate and encompassed the structural support system and the building enclosure. Floor plans, elevations, material quantities, and structural loads associated with a five-storey concrete-framed building design were obtained from issued-for-construction drawings. A functionally equivalent, laminated timber hybrid design was conceived, based on Canadian Building Code requirements. Design values for locally produced CLT panels were established from in-house material testing. Primary data collected from a pilot-scale manufacturing facility was used to develop the life cycle inventory for CLT, whereas secondary sources were referenced for other construction materials. The TRACI characterization methodology was employed to translate inventory flows into impact indicators. The results indicated that the laminated timber building design offered a lower environmental impact in 10 of 11 assessment categories. The cradle-to-gate process energy was found to be nearly identical in both design scenarios (3.5 GJ/m2, whereas the cumulative embodied energy (feedstock plus process of construction materials was estimated to be 8.2 and 4.6 GJ/m2 for the timber and concrete designs, respectively; which indicated an increased availability of readily accessible potential energy stored within the building materials of the timber alternative.

  13. Study and Optimization of Design Parameters in Water Loop Heat Pump Systems for Office Buildings in the Iberian Peninsula

    Directory of Open Access Journals (Sweden)

    Francisco Javier Fernández

    2017-11-01

    Full Text Available Water loop heat pump (WLHP air conditioning systems use heat pumps connected to a common water circuit to fulfill the energy demands of different thermal zones in a building. In this study, the energy consumption was analyzed for the air conditioning of an office building in the typical climate of four important cities of the Iberian Peninsula. The energy consumption of one water loop heat pump system was compared with a conventional water system. Two design parameters, the range in the control temperatures and the water loop thermal storage size, were tested. Energy redistribution is an important advantage of the WLHP system, but significant savings came from high efficiency parameters in the heat pumps and minor air flow rates in the cooling tower. The low thermal level in the water loop makes this technology appropriate to combine with renewable sources. Using natural gas as the thermal energy source, a mean decrease in CO2 emissions of 8.1% was reached. Simulations showed that the installation of big thermal storage tanks generated small energy savings. Besides, the total annual consumption in buildings with high internal loads can be reduced by keeping the water loop as cool as possible.

  14. Quality and satisfaction of thermal comfort in Dutch offices

    NARCIS (Netherlands)

    Brink, Henk Willem; Mobach, Mark P.; Balslev Nielsen, S.; Jensen, P.A.

    2016-01-01

    Purpose: This field study analyses the quality of the actual thermal comfort and indoor air quality in Dutch office buildings. A linear regression analysis was used to determine how much these variables and demographic variables influenced the perceived thermal comfort of office workers. Approach:

  15. International political symbolism of the architecture of government buildings

    Directory of Open Access Journals (Sweden)

    V. V. Kochetkov

    2015-01-01

    Full Text Available The article analyzes international political architecture of government buildings in Russia, the U.S., Western Europe (UK, France, Germany and Asia (China, India, Japan. Conclusions that the architecture of government buildings reflects the values of the dominant society’s political culture. Some government buildings are prototypes constructed previously in other societies and cultural traditions (for instance, the Capitol in Washington, USA, and the Capitoline temple in Rome.

  16. Plataforma smart building

    OpenAIRE

    Cidrera Lopez, Alain

    2013-01-01

    The overall project is a system (hardware + software) that allows monitoring and control in a building / office different security systems, energy, communications, home automation, PKI's overall business that will increase all the efficiency of the building and the business and ensure the continuity of it. My participation in this Project will mainly focus on the development of hardware components, monitoring and control system (home automation, energy, safety control elements ...) and softwa...

  17. 49 CFR 41.119 - DOT regulated buildings.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false DOT regulated buildings. 41.119 Section 41.119 Transportation Office of the Secretary of Transportation SEISMIC SAFETY § 41.119 DOT regulated buildings. (a) Each DOT Operating Administration with responsibility for regulating the structural safety of buildings...

  18. Government regulation and associated innovations in building energy-efficiency supervisory systems for large-scale public buildings in a market economy

    International Nuclear Information System (INIS)

    Dai Xuezhi; Wu Yong; Di Yanqiang; Li Qiaoyan

    2009-01-01

    The supervision of energy efficiency in government office buildings and large-scale public buildings is the main embodiment for government implementation of Public Administration in the fields of resource saving and environmental protection. Aimed at improving the current situation of lack of government administration in building energy efficiency, this paper proposes the concept of 'change and redesign of governmental supervision in building energy efficiency', repositioning the role of government supervision. Based on this theory and other related theories in regulation economic and modern management, this paper analyzes and researches the action and function of all level governments in execution of the supervisory system of building energy efficiency in government office buildings and large-scale public buildings. This paper also defines the importance of government supervision in energy-efficiency system. Finally, this paper analyzes and researches the interaction mechanism between government and owners of different type buildings, government and energy-efficiency service institution with gambling as main features. This paper also presents some measurements to achieve a common benefit community in implementation of building energy-efficiency supervisory system.

  19. Government regulation and associated innovations in building energy-efficiency supervisory systems for large-scale public buildings in a market economy

    Energy Technology Data Exchange (ETDEWEB)

    Dai Xuezhi [China Academy of Building Research, Beijing 100013 (China)], E-mail: daixz9999@126.com; Wu Yong [Ministry of Housing and Urban-Rural Development of the People' s Republic of China, Beijing 100835 (China); Di Yanqiang [China Academy of Building Research, Beijing 100013 (China); Li Qiaoyan [Department of Building, School of Design and Environment, National University of Singapore (Singapore)

    2009-06-15

    The supervision of energy efficiency in government office buildings and large-scale public buildings is the main embodiment for government implementation of Public Administration in the fields of resource saving and environmental protection. Aimed at improving the current situation of lack of government administration in building energy efficiency, this paper proposes the concept of 'change and redesign of governmental supervision in building energy efficiency', repositioning the role of government supervision. Based on this theory and other related theories in regulation economic and modern management, this paper analyzes and researches the action and function of all level governments in execution of the supervisory system of building energy efficiency in government office buildings and large-scale public buildings. This paper also defines the importance of government supervision in energy-efficiency system. Finally, this paper analyzes and researches the interaction mechanism between government and owners of different type buildings, government and energy-efficiency service institution with gambling as main features. This paper also presents some measurements to achieve a common benefit community in implementation of building energy-efficiency supervisory system.

  20. Government regulation and associated innovations in building energy-efficiency supervisory systems for large-scale public buildings in a market economy

    Energy Technology Data Exchange (ETDEWEB)

    Dai, Xuezhi; Di, Yanqiang [China Academy of Building Research, Beijing 100013 (China); Wu, Yong [Ministry of Housing and Urban-Rural Development of the People' s Republic of China, Beijing 100835 (China); Li, Qiaoyan [Department of Building, School of Design and Environment, National University of Singapore (Singapore)

    2009-06-15

    The supervision of energy efficiency in government office buildings and large-scale public buildings is the main embodiment for government implementation of Public Administration in the fields of resource saving and environmental protection. Aimed at improving the current situation of lack of government administration in building energy efficiency, this paper proposes the concept of 'change and redesign of governmental supervision in building energy efficiency', repositioning the role of government supervision. Based on this theory and other related theories in regulation economic and modern management, this paper analyzes and researches the action and function of all level governments in execution of the supervisory system of building energy efficiency in government office buildings and large-scale public buildings. This paper also defines the importance of government supervision in energy-efficiency system. Finally, this paper analyzes and researches the interaction mechanism between government and owners of different type buildings, government and energy-efficiency service institution with gambling as main features. This paper also presents some measurements to achieve a common benefit community in implementation of building energy-efficiency supervisory system. (author)

  1. Development and Evaluation of the Virtual Prototype of the First Saudi Arabian-Designed Car

    Directory of Open Access Journals (Sweden)

    Mustufa H. Abidi

    2016-10-01

    Full Text Available Prototyping and evaluation are imperative phases of the present product design and development process. Although digital modeling and analysis methods are widely employed at various product development stages, still, building a physical prototype makes the present typical process expensive and time consuming. Therefore, it is necessary to implement new technologies, such as virtual prototyping, which can enable industry to have a rapid and more controlled decision making process. Virtual prototyping has come a long way in recent years, where current environments enable stereoscopic visuals, surround sound and ample interaction with the generated models. It is also important to evaluate how representative the developed virtual prototype is when compared to the real-world counterpart and the sense of presence reported by users of the virtual prototype. This paper describes the systematic procedure to develop a virtual prototype of Gazal-1 (i.e., the first car prototype designed by Saudi engineers in a semi-immersive virtual environment. The steps to develop a virtual prototype from CAD (computer-aided design models are explained in detail. Various issues involved in the different phases for the development of the virtual prototype are also discussed comprehensively. The paper further describes the results of the subjective assessment of a developed virtual prototype of a Saudi Arabian-designed automobile. User’s feedback is recorded using a presence questionnaire. Based on the user-based study, it is revealed that the virtual prototype is representative of the real Saudi Arabian car and offers a flexible environment to analyze design features when compared against its physical prototype. The capabilities of the virtual environment are validated with the application of the car prototype. Finally, vital requirements and directions for future research are also presented.

  2. Evaluation of solar thermal driven cooling system in office buildings in Saudi Arabia

    Science.gov (United States)

    Linjawi, Majid T.; Talal, Qazi; Al-Sulaiman, Fahad A.

    2017-11-01

    In this study solar driven absorption chiller is used to reduce the peak cooling load in office buildings in Saudi Arabia for different selected cities. The study is conducted for six cities of Abha, Dhahran, Hail, Jeddah, Nejran and Riyadh under three operating durations of 4, 6, and 8 hours using flat plate or evacuated tube collectors. The energy analysis concluded that flat plate collectors are better than evacuated tube collectors. However, the results from economic analysis suggest that while proposing a gas fired absorption chiller will reduce running costs, further reduction by using solar collectors is not feasible because of its high initial cost. At the best case scenario the Net Present Value of a 10 Ton Absorption chiller operated by natural gas boiler and two large flat plate collectors (12m2 each) running for 8 hours/day, 5days/week has a value of 117,000 and Internal Rate of Return (IRR) of 12%. Solar driven absorption chiller could be more feasible if the gas prices increases or the solar collector prices decreases significantly. Finally, government economic incentives and taxes are recommended to provide a boost for the feasibility of such projects.

  3. Teaching Tip: Using Rapid Game Prototyping for Exploring Requirements Discovery and Modeling

    Science.gov (United States)

    Dalal, Nikunj

    2012-01-01

    We describe the use of rapid game prototyping as a pedagogic technique to experientially explore and learn requirements discovery, modeling, and specification in systems analysis and design courses. Students have a natural interest in gaming that transcends age, gender, and background. Rapid digital game creation is used to build computer games…

  4. Enhancing experience prototyping by the help of mixed-fidelity prototypes

    OpenAIRE

    Yasar, Ansar-Ul-Haque

    2007-01-01

    In this research review I undertook the problem related to the usage of a new concept known as the Mixed- Fidelity Prototype which is a mixture of its predecessors Low- and High- Fidelity Prototypes in Experience Prototyping. Experience Prototyping is a good way to explore, communicate and interact with the designs we develop like experiencing cycling on the ice, although the mood, snow conditions, bicycle type and many other factors really matter and tend to change with time. Experience Prot...

  5. Environmental Conditions and Occupant Perceptions in European Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Stoops, J.L. [Chalmers Univ. of Tech., Goeteborg (Sweden). Dept. of Building Services Engineering

    2003-03-01

    This is a preliminary report regarding a portion of the environmental conditions and occupant comfort perceptions from a five nation, 26 building European field data collection effort. Approximately 1,000 participants were involved in this project which included twelve monthly visits to each building. Climate, building and cultural variation will be illustrated for the five countries involved - France, Greece, Portugal, Sweden and the United Kingdom (UK). Each country used identical instrumentation; questionnaires and experimental protocols imbedded in a custom hardware/software system. The comfort survey was based on the ASHRAE model. The physical measurements included air temperature, globe temperature, relative humidity, air movement, CO{sub 2}, light, and sound levels. Where possible, connections and explanations between variables are made. Potential energy and policy ramifications are illustrated. (The publication includes two reports from EU JOULE III projects JOE3CT970066 'Smart controls and thermal comfort project)

  6. Accelerating the energy retrofit of commercial buildings using a database of energy efficiency performance

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Hong, Tianzhen; Piette, Mary Ann; Sawaya, Geof; Chen, Yixing; Taylor-Lange, Sarah C.

    2015-01-01

    Small and medium-sized commercial buildings can be retrofitted to significantly reduce their energy use, however it is a huge challenge as owners usually lack of the expertise and resources to conduct detailed on-site energy audit to identify and evaluate cost-effective energy technologies. This study presents a DEEP (database of energy efficiency performance) that provides a direct resource for quick retrofit analysis of commercial buildings. DEEP, compiled from the results of about ten million EnergyPlus simulations, enables an easy screening of ECMs (energy conservation measures) and retrofit analysis. The simulations utilize prototype models representative of small and mid-size offices and retails in California climates. In the formulation of DEEP, large scale EnergyPlus simulations were conducted on high performance computing clusters to evaluate hundreds of individual and packaged ECMs covering envelope, lighting, heating, ventilation, air-conditioning, plug-loads, and service hot water. The architecture and simulation environment to create DEEP is flexible and can expand to cover additional building types, additional climates, and new ECMs. In this study DEEP is integrated into a web-based retrofit toolkit, the Commercial Building Energy Saver, which provides a platform for energy retrofit decision making by querying DEEP and unearthing recommended ECMs, their estimated energy savings and financial payback. - Highlights: • A DEEP (database of energy efficiency performance) supports building retrofit. • DEEP is an SQL database with pre-simulated results from 10 million EnergyPlus runs. • DEEP covers 7 building types, 6 vintages, 16 climates, and 100 energy measures. • DEEP accelerates retrofit of small commercial buildings to save energy use and cost. • DEEP can be expanded and integrated with third-party energy software tools.

  7. Improving indoor air quality and thermal comfort in office building by using combination filters

    Science.gov (United States)

    Kabrein, H.; Yusof, M. Z. M.; Hariri, A.; Leman, A. M.; Afandi, A.

    2017-09-01

    Poor indoor air quality and thermal comfort condition in the workspace affected the occupants’ health and work productivity, especially when adapting the recirculation of air in heating ventilation and air-conditioning (HVAC) system. The recirculation of air was implemented in this study by mixing the circulated returned indoor air with the outdoor fresh air. The aims of this study are to assess the indoor thermal comfort and indoor air quality (IAQ) in the office buildings, equipped with combination filters. The air filtration technique consisting minimum efficiency reporting value (MERV) filter and activated carbon fiber (ACF) filter, located before the fan coil units. The findings of the study show that the technique of mixing recirculation air with the fresh air through the combination filters met the recommended thermal comfort condition in the workspace. Furthermore, the result of the post-occupancy evaluation (POE) and the environmental measurements comply with the ASHRAE 55 standard. In addition, the level of CO2 concentration continued to decrease during the period of the measurement.

  8. Medication Reconciliation: Work Domain Ontology, prototype development, and a predictive model.

    Science.gov (United States)

    Markowitz, Eliz; Bernstam, Elmer V; Herskovic, Jorge; Zhang, Jiajie; Shneiderman, Ben; Plaisant, Catherine; Johnson, Todd R

    2011-01-01

    Medication errors can result from administration inaccuracies at any point of care and are a major cause for concern. To develop a successful Medication Reconciliation (MR) tool, we believe it necessary to build a Work Domain Ontology (WDO) for the MR process. A WDO defines the explicit, abstract, implementation-independent description of the task by separating the task from work context, application technology, and cognitive architecture. We developed a prototype based upon the WDO and designed to adhere to standard principles of interface design. The prototype was compared to Legacy Health System's and Pre-Admission Medication List Builder MR tools via a Keystroke-Level Model analysis for three MR tasks. The analysis found the prototype requires the fewest mental operations, completes tasks in the fewest steps, and completes tasks in the least amount of time. Accordingly, we believe that developing a MR tool, based upon the WDO and user interface guidelines, improves user efficiency and reduces cognitive load.

  9. Outbreak of eczema and rhinitis in a group of office workers in Greenland

    DEFF Research Database (Denmark)

    Ebbehøj, Niels E; Agner, Tove; Zimerson, Erik

    2015-01-01

    INTRODUCTION: Disturbed indoor climate may in some cases be associated with illness. In the present paper, we report the results from a thorough investigation of office workers in Greenland, who developed skin and/or airway problems after moving into renewed offices. MATERIAL AND METHODS: In 2009...... the office of the Bank of Greenland had a total renovation of the building, including new furniture and carpets. Symptoms developed within the first year after moving back into the renewed buildings. After removal of carpets in the building, symptoms significantly improved. Workers were examined in 2009......: In total, 32 out of 80 workers (40%) developed symptoms; 27 reported eczema, 20 rhinitis and 4 urticaria. Eczema was located on the hands and/or lower arms in 18 workers, on the face in 10 workers and on legs/trunk in 12 workers. After intervention in the office, 22 workers with eczema reported significant...

  10. Green buildings pay

    DEFF Research Database (Denmark)

    Naboni, Emanuele; Edwards, Brian

    The new edition of ‘Green Buildings Pay’ authored by Brian Edwards and Emanuele Naboni explores the business and professional benefits which derive from architectural design driven by sustainability. With a new sub-title ‘Green Buildings Pay: design, productivity and ecology’ the book argues...... that environmental design has altered how we design, construct and manage buildings. The book has relevance to those who not only design and engineer buildings but to those who commission architecture and those who occupy the products of this process. Hence, the user is a key consideration. The book examines via...... a number of LEED and BREEAM cases the buildings which flow from corporate environmental responsibility. A number of office and university buildings are examined from three main perspectives- the architect, client and user. One key finding is that architectural innovation has been driven by ecological...

  11. Mentoring the Afghan Army at the Officer Academy in Kabul

    DEFF Research Database (Denmark)

    Mynster Christensen, Maya

    Capacity building of host nation militaries is a central component of current multinational military operations, which is likely to become increasingly vital to future military interventions in conflict settings. Focusing on the mentoring of the Afghan National Army at the British-led officer...... academy in Kabul, this policy brief stresses the urgency with which Western militaries should improve military capacity building efforts. Based on qualitative data collected at the British Royal Military Academy Sandhurst and the Afghan National Army Officer Academy, the brief outlines five clusters...

  12. Perceived office environments and occupational physical activity in office-based workers.

    Science.gov (United States)

    Sawyer, A; Smith, L; Ucci, M; Jones, R; Marmot, A; Fisher, A

    2017-06-01

    Individuals in office-based occupations have low levels of physical activity but there is little research into the socio-ecological correlates of workplace activity. To identify factors contributing to office-based workers' perceptions of the office environment and explore cross-sectional relationships between these factors and occupational physical activity. Participants in the Active Buildings study reported perceptions of their office environment using the Movement at Work Survey. A principal component analysis (PCA) was conducted on survey items. A sub-sample wore the ActivPAL3TM accelerometer for ≥3 workdays to measure occupational step count, standing, sitting and sit-to-stand transitions. Linear regression analyses assessed relationships between environmental perceptions and activity. There were 433 participants, with accelerometer data available for 115 participants across 11 organ izations. The PCA revealed four factors: (i) perceived distance to office destinations, (ii) perceived office aesthetics and comfort, (iii) perceived office social environment and (iv) perceived management discouragement of unscheduled breaks. Younger participants perceived office destinations as being closer to their desk. Younger and female participants perceived more positive office social environments; there were no other socio-demographic differences. Within the sub-sample with accelerometer data, perceived discouragement of breaks by management was related to occupational step count/hour (B = -64.5; 95% CI -109.7 to -19.2). No other environmental perceptions were related to activity or sitting. Perceived managerial discouragement of breaks could be related to meaningful decreases in occupational step count. Future research should aim to elucidate the role of the workplace socio-cultural environment in occupational walking, with a focus on the role of management. © The Author 2017. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All

  13. Comparison between Dutch and German buildings

    Energy Technology Data Exchange (ETDEWEB)

    Lony, R.J.M.; Molenaar, D.J.; Rietkerk, J.; Schuiling, D.J.B.W.; Zeiler, W. [TU/e, Univ. of Technology Eindhoven (Netherlands); Brunk, M. [RWTH Aachen (Germany)

    2006-07-01

    German buildings are often seen as an example to Dutch architects and Dutch building services consultants. Goal of this article is to examine and to understand differences between the Dutch and German top office buildings. Objective is to examine to which extent these buildings were designed intelligently. An Intelligent Building is one that provides a productive cost effective environment through the optimisation of six basic elements; site, skin, systems, structures, services, space plan and staff and the interrelationship between them. Based on these six aspects the comparison is made between Dutch and German buildings. (orig.)

  14. Analysis for Building Envelopes and Mechanical Systems Using 2012 CBECS Data

    Energy Technology Data Exchange (ETDEWEB)

    Winiarski, David W.; Halverson, Mark A.; Butzbaugh, Joshua B.; Cooke, Alan L.; Bandyopadhyay, Gopal K.; Elliott, Douglas B.

    2018-03-14

    This report describes the aggregation and mapping of certain building characteristics data available in the most recent Commercial Building Energy Consumption Survey (CBECS) (DOE EIA 2012) to describe most typical building construction practices. This report provides summary data for potential use in the support of modifications to the Pacific Northwest National Laboratory’s commercial building prototypes used for building energy code analysis. Specifically, this report outlines findings and most typical design choices for certain building envelope and heating, ventilating, and air-conditioning (HVAC) system choices.

  15. Simulation of energy- efficient building prototype using different insulating materials

    Science.gov (United States)

    Ouhaibi, Salma; Belouaggadia, Naoual; Lbibb, Rachid; Ezzine, Mohammed

    2018-05-01

    The objective of this work is to analyze the energetic efficiency of an individual building including an area of 130 m2 multi-zone, located in the region of FEZ which is characterized by a very hot and dry climate in summer and a quite cold one in winter, by incorporating insulating materials. This study was performed using TRNSYS V16 simulation software during a typical year of the FEZ region. Our simulation consists in developing a comparative study of two types of polystyrene and silica-aerogel insulation materials, in order to determine the best thermal performance. The results show that the thermal insulation of the building envelope is among the most effective solutions that give a significant reduction in energy requirements. Similarly, the use of silica-aerogels gives a good thermal performance, and therefore a good energy gain.

  16. Critical Success Factors in Sustainable Office Development in the Netherlands.

    NARCIS (Netherlands)

    Vink, A.J.G.; Abdalla, G.; Favie, R.; Huyghe, J.M.R.J.; Maas, G.J.

    2010-01-01

    Commercial buildings are responsible for large percentage of the global emission of greenhouse. The development of sustainable offices is being driven by ecological and political motifs as well as by economical and social arguments. Despite all efforts to encourage it, sustainable office development

  17. Radon in public buildings

    International Nuclear Information System (INIS)

    Schulz, H.; Flesch, K.; Hermann, E.; Loebner, W.; Leissring, B.

    2009-01-01

    From the Free State of Saxony, a study was commissioned to survey how reliable measurements to characterize the radon situation in public buildings at a reasonable financial and human effort can be carried out to reduce radiation exposure in public buildings. The study approach was for 6 objects. To characterize the radon situation the time evolution measurement of radon concentrations of more than 1 to 2 weeks turned out to be sufficient. A novel data analysis enables the identification of a ''typical daily alteration of the radon concentration'' depending on the ventilation conditions and the daily use of the offices or class rooms. The identification of typical diurnal radon variations for the working time and weekends or holidays is of fundamental importance for assessing the exposure situation in public buildings. It was shown that the radon concentration during working time are in general much lower than in the times when the buildings (offices) are unused. It turned out that the long-term radon measurements with nuclear track detectors within distinct time regimes (day / night, working hours / leisure time) by utilizing switch modules are very efficient to estimate the actual exposure. (orig.)

  18. Use of standalone photovoltaic system for office building: the case ...

    African Journals Online (AJOL)

    This paper presents the design of a cost effective energy system for National Centre for Hydropower Research and Development (NACHRED) building to supply its daily energy requirements. The daily hourly load demand of the building was measured with FLUKE 434 Series II Energy Analyzer. The measurement was ...

  19. Passive solar offices: integrated design

    Energy Technology Data Exchange (ETDEWEB)

    Evans, B

    1992-05-06

    Passive solar design in out-of-town offices can remove the need for air-conditioning by making greater use of daylight and natural ventilation. To promote the use of passive solar energy a series of design studies are being run by the Energy Technology Support Unit on behalf of the Department of Energy. The three reported here are designs for out-of-town business buildings. Each is a hypothetical building designed to a realistic brief for an organisation taking the role of real client. (author).

  20. Investigating the role of implicit prototypes in the prototype willingness model.

    Science.gov (United States)

    Howell, Jennifer L; Ratliff, Kate A

    2017-06-01

    One useful theory to predict health behavior is the prototype-willingness model (PWM), which posits that people are more willing to engage in behavior to the extent that they have a positive view of the prototypical person who performs that behavior. The goal of the present research is to test whether adding an implicit measure of prototype favorability might improve explanatory power in the PWM. Two studies examined whether implicit prototype favorability uniquely predicted White women's intentions to engage in healthy sun behavior over the next 3-6 months, and their willingness to engage in risky sun behavior, should the opportunity arise. The results suggested that implicit prototype favorability, particularly implicit prototypes of those who engage in risky UV-related behaviors, uniquely predicted intentions to engage in healthy sun behavior and willingness to engage in risky sun behavior in the PWM.

  1. A room-temperature liquid calorimeter prototype for the SSC

    International Nuclear Information System (INIS)

    Brandenburg, G.W.; Geer, S.H.; Oliver, J.; Sadowski, E.; Theriot, D.

    1990-01-01

    Calorimeters will be an extremely important part of SSC detectors as they have been in existing collider detectors. The main issues that need to be addressed are: (1) energy resolution of jets and electrons, (2) segmentation, (3) hermiticity, (4) response time, and (5) radiation resistance. An attractive possibility on all these counts is the use of room-temperature liquids together with uranium, as pioneered by UA1. The authors are planning a prototype calorimeter which consists of a sealed vessel containing both the radiator plates and the readout pads. This geometry has been appropriately named the swimming pool design. The general mechanical starting point is similar to the SLD liquid argon calorimeters. The points they wish to address are the following: (1) Simple and reliable modular construction techniques, (2) Satisfactory electrical connections with minimal geometric impact, (3) The necessity of isolating radiator plates and liquid to maintain purity, (4) What materials can be immersed without compromising the liquid purity. The design and construction of the swimming pool electromagnetic calorimeter prototype is being carried out at the Harvard High Energy Physics Laboratory. This is one of the first attempts to build a full-scale prototype of such a design

  2. Software Prototyping

    Science.gov (United States)

    Del Fiol, Guilherme; Hanseler, Haley; Crouch, Barbara Insley; Cummins, Mollie R.

    2016-01-01

    Summary Background Health information exchange (HIE) between Poison Control Centers (PCCs) and Emergency Departments (EDs) could improve care of poisoned patients. However, PCC information systems are not designed to facilitate HIE with EDs; therefore, we are developing specialized software to support HIE within the normal workflow of the PCC using user-centered design and rapid prototyping. Objective To describe the design of an HIE dashboard and the refinement of user requirements through rapid prototyping. Methods Using previously elicited user requirements, we designed low-fidelity sketches of designs on paper with iterative refinement. Next, we designed an interactive high-fidelity prototype and conducted scenario-based usability tests with end users. Users were asked to think aloud while accomplishing tasks related to a case vignette. After testing, the users provided feedback and evaluated the prototype using the System Usability Scale (SUS). Results Survey results from three users provided useful feedback that was then incorporated into the design. After achieving a stable design, we used the prototype itself as the specification for development of the actual software. Benefits of prototyping included having 1) subject-matter experts heavily involved with the design; 2) flexibility to make rapid changes, 3) the ability to minimize software development efforts early in the design stage; 4) rapid finalization of requirements; 5) early visualization of designs; 6) and a powerful vehicle for communication of the design to the programmers. Challenges included 1) time and effort to develop the prototypes and case scenarios; 2) no simulation of system performance; 3) not having all proposed functionality available in the final product; and 4) missing needed data elements in the PCC information system. PMID:27081404

  3. Acoustical case studies of three green buildings

    Science.gov (United States)

    Siebein, Gary; Lilkendey, Robert; Skorski, Stephen

    2005-04-01

    Case studies of 3 green buildings with LEED certifications that required extensive acoustical retrofit work to become satisfactory work environments for their intended user groups will be used to define areas where green building design concepts and acoustical design concepts require reconciliation. Case study 1 is an office and conference center for a city environmental education agency. Large open spaces intended to collect daylight through clerestory windows provided large, reverberant volumes with few acoustic finishes that rendered them unsuitable as open office space and a conference room/auditorium. Case Study 2 describes one of the first gold LEED buildings in the southeast whose primary design concepts were so narrowly focused on thermal and lighting issues that they often worked directly against basic acoustical requirements resulting in sound levels of NC 50-55 in classrooms and faculty offices, crosstalk between classrooms and poor room acoustics. Case study 3 is an environmental education and conference center with open public areas, very high ceilings, and all reflective surfaces made from wood and other environmentally friendly materials that result in excessive loudness when the building is used by the numbers of people which it was intended to serve.

  4. External walls made of solar Lego bricks. Sulfurcell head office building: External wall construction according to the dimensions of Sulfurcell solar modules; Solare Legosteinfassade. Die Masse der hauseigenen Module bildeten den Ausgangspunkt fuer die Planung des Sulfurcell-Hauptquartiers

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Neelke

    2009-11-15

    The Sulfurcell Solartechnik GmbH constructed a new office building at Berlin-Adlershof. The building's external walls were designed on the basis of the frameless Sulfurcell standard module. The building intends to prove that solar modules are not a luxury item but an efficient and easy-to-handle constructional material. (orig.)

  5. Energetic performances of an optimized passive Solar Heating Prototype used for Tunisian buildings air-heating application

    International Nuclear Information System (INIS)

    Mehdaoui, Farah; Hazami, Majdi; Naili, Nabiha; Farhat, Abdelhamid

    2014-01-01

    Highlights: • The study of a Solar Heating Prototype to prevail the buildings air-heating needs. • A parametric study of the system was achieved by means of the TRNSYS program. • The monthly internal temperature during cold months ranges between 22 and 25 °C. • The results shows that the relative humidity inside the monozone room of about 40%. - Abstract: This paper deals with the energetic performances of a Solar Heating Prototype (SHP) conceived in our laboratory to prevail the Tunisian households’ air-heating needs. The conceived SHP mainly consists of a flat-plate solar collector, solar hot water tank and an active layer integrated inside a single room. Firstly, a complete model is formulated taking into account various modes of heat transfer in the SHP by means of the TRNSYS simulation program. To validate the TRNSYS model, experimental tests under local weather conditions were performed for 2 days spread over 2 months (March and April 2013). Predicted results were compared to the measurements in order to determine the accuracy of the simulation program. A parametric study was then achieved by means of the TRNSYS program in order to optimize SHP design parameters (Collector area, collector mass flow rate, floor mass flow rate, storage tank volume and thickness of the active layer). The optimization of all design parameters shows that to achieve a maximum performances from the SHP it is essential to use a solar collector with an area equal to 6 m 2 area, a collector mass flow rate equal to 100 kg h −1 and a hot water storage tank with a capacity equal to 450 l. Concerning the floor heating, the optimal values of mass flow rate and the active layer thickness are 200 kg h −1 and 0.06 m, respectively. The long-term SHP performances were afterward evaluated by means of the Typical Meteorological Year (TMY) data relative to Tunis, Tunisia. Results showed that for an annual total solar insolation of about 6493.37 MJ m −2 the average solar fraction

  6. Microsoft® Office Access™ 2007 Step by Step

    CERN Document Server

    Lambert, Steve; Lambert, Joan

    2009-01-01

    Experience learning made easy-and quickly teach yourself how to build database solutions with Access 2007. With Step By Step, you set the pace-building and practicing the skills you need, just when you need them! Build databases from scratch or from templatesExchange data with other databases and Office documentsCreate forms to simplify data entryUse filters and queries to find and analyze informationDesign rich reports that help make your data meaningfulHelp prevent data corruption and unauthorized access Your all-in-one learning experience includes: Files for building skills and practic

  7. Ceramics and healthy heating and cooling systems: thermal ceramic panels in buildings. Conditions of comfort and energy demand versus convective systems

    Directory of Open Access Journals (Sweden)

    V. Echarri Iribarren

    2016-12-01

    Full Text Available Porcelain stoneware is a widely used building material. In recent years, its range of uses has expanded to encompass a new spectrum of innovative and inventive applications in architecture. In this research, we analysed the patented Thermal Ceramic Panel. This consists of a thin porcelain stoneware panel that incorporates a capillary system of polypropylene tubes measuring 3.5 mm in diameter embedded in a conductive ceramic interface. The system works with hot or cold water, producing healthy heating and cooling by means of radiant surfaces. Following an initial prototype test in which panels were placed on the walls of an office, we conducted simulations at the University of Alicante Museum using wall, ceiling and baffle panels, having previously monitored the state of the building. Thermal behaviour parameters were analysed and compared with those of other standard finishing materials, obtaining results for thermal comfort and energy savings in comparison with all-air systems.

  8. Building Efficiency Technologies by Tomorrow’s Engineers and Researchers (BETTER) Capstone. Final Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Yee, Shannon [Georgia Inst. of Technology, Atlanta, GA (United States)

    2017-09-30

    BETTER Capstone supported 29 student project teams consisting of 155 students over two years in developing transformative building energy efficiency technologies through a capstone design experience. Capstone is the culmination of an undergraduate student’s engineering education. Interdisciplinary teams of students spent a semester designing and prototyping a technological solution for a variety building energy efficiency problems. During this experience students utilized the full design process, including the manufacturing and testing of a prototype solution, as well as publically demonstrating the solution at the Capstone Design Expo. As part of this project, students explored modern manufacturing techniques and gained hands-on experience with these techniques to produce their prototype technologies. This research added to the understanding of the challenges within building technology education and engagement with industry. One goal of the project was to help break the chicken-and-egg problem with getting students to engage more deeply with the building technology industry. It was learned however that this industry is less interested in trying innovative new concept but rather interested in hiring graduates for existing conventional building efforts. While none of the projects yielded commercial success, much individual student growth and learning was accomplished, which is a long-term benefit to the public at large.

  9. Thermographic survey of two rural buildings in Spain

    Energy Technology Data Exchange (ETDEWEB)

    Martin Ocana, S.; Canas Guerrero, I. [Departamento de Construccion y Vias Rurales, Escuela Tecnica Superior de Ingenieros Agronomos, Universidad Politecnica de Madrid, Madrid (Spain); Gonzalez Requena, I. [Departamento de Materiales y Produccion Aeroespacial, Escuela Tecnica Superior de Ingenieros Aeronauticos, Universidad Politecnica de Madrid, Madrid (Spain)

    2004-07-01

    Two common housing prototypes of existing buildings in Spanish rural areas were surveyed by infrared inspection. The aim of the study is to assess the usefulness of infrared thermography as a technique for the detection of the thermal performance of rural buildings. For the traditional house the best results were obtained in the thermographic survey carried out in the evening. Contrarily, for the modern house the thermographic survey at daybreak provided more information. Infrared thermography allowed the comparison of the thermal performance of two buildings. (author)

  10. Research Support Facility (RSF): Leadership in Building Performance (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2011-09-01

    This brochure/poster provides information on the features of the Research Support Facility including a detailed illustration of the facility with call outs of energy efficiency and renewable energy technologies. Imagine an office building so energy efficient that its occupants consume only the amount of energy generated by renewable power on the building site. The building, the Research Support Facility (RSF) occupied by the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) employees, uses 50% less energy than if it were built to current commercial code and achieves the U.S. Green Building Council's Leadership in Energy and Environmental Design (LEED{reg_sign}) Platinum rating. With 19% of the primary energy in the U.S. consumed by commercial buildings, the RSF is changing the way commercial office buildings are designed and built.

  11. Main building fire drill safely concluded

    CERN Document Server

    CERN Bulletin

    2015-01-01

    Last week, a simulated fire in the stairwell of the Main Building put CERN’s emergency response procedures to the test.   Firefighters descend the stairwell in the Main Building as the simulated fire rises.   At 2 p.m. on 22 September, alarms sounded around CERN’s Main Building as an evacuation exercise got underway. A simulated fire in the  stairwell, complete with very realistic smoke, led to the evacuation of one of the busiest places at CERN. The Main Building complex includes the Carlson Wagonlit travel agency, the post office, UBS, Uniqa, the Users Office, the Staff Association and the Novae restaurant as well as the Main Auditorium, the Council Chamber and the Charpak meeting room. It was impressive to see how quickly the smoke propagated in the staircase as well as into the corridors, and equally impressive to see how smoothly, quickly and efficiently the evacuation proceeded. The...

  12. 76 FR 64931 - Building Energy Codes Cost Analysis

    Science.gov (United States)

    2011-10-19

    ...-0046] Building Energy Codes Cost Analysis AGENCY: Office of Energy Efficiency and Renewable Energy... reopening of the time period for submitting comments on the request for information on Building Energy Codes... the request for information on Building Energy Code Cost Analysis and provide docket number EERE-2011...

  13. GEDUNG PAMERAN PRODUK ARSITEKTUR DAN INERIOR DI KOTA MAKASSAR DENGAN PENDEKATAN ECO-OFFICE

    Directory of Open Access Journals (Sweden)

    Muhammad Husnul

    2017-04-01

    Full Text Available Plaining and design of the bulding aims to design building of architecture and interior products exhibitions in the city of Makassar with emphasis Eco-Office, this design is limited to a few problems, there are the architectural issue, particulary spatial, space recurements and building appearance. The method issued is the study of literature/ literary studies, surveys (in the from of field observations and data collection of function of the building where has a similar to the trade fair, and analsis of the data obtained. The result of the creation of the design architecture and interior products exhibition builing in the city of Makassar with emphaisis Eco-Office, with the ability of building to accommodate currently building development without compromising environmental aspects.

  14. Change of offices for HR Department - disrupted service during the last week of February 2013

    CERN Multimedia

    2013-01-01

    HR Department would like to inform that, due to office renovation work, a number of HR Services currently located on the ground, first and second floors of Building 5 will move to temporary offices as from late February.   The removals will take place from Friday 22 until Tuesday 26 February 2013 inclusive and during this period, telephone and e-mail contact may be disrupted. The following services will be relocated to: Building 510  – ground floor (until mid-June) Head of Department and Deputy Office of the Head of HR Department Group Leaders and Partners Diversity Office HR Legal Section Building 652 – Prefab/Algeco (until September) Human Resources Advisors and assistants Staff Recruitment Service Fellows & Apprentices Service Students & Associates Service Temporary office numbers will be available in the CERN phonebook. Any emergencies during the removals may be addressed to Lynda.Leroux@cern.ch Thank you in advance for your understanding. HR Head O...

  15. Radon in large buildings

    International Nuclear Information System (INIS)

    Wilson, D.L.; Dudney, C.S.; Gammage, R.B.

    1993-01-01

    Over the past several years, considerable research has been devoted by the U.S. Environmental Protection Agency (USEPA) and others to develop radon sampling protocols for single family residences and schools. However, very little research has been performed on measuring radon in the work place. To evaluate possible sampling protocols, 833 buildings throughout the United States were selected for extensive radon testing. The buildings tested (warehouses, production plants and office buildings) were representative of commercial buildings across the country both in design, size and use. Based on the results, preliminary radon sampling protocols for the work place have been developed. (orig.). (5 refs., 3 figs.)

  16. Building Standards and Codes for Energy Conservation

    Science.gov (United States)

    Gross, James G.; Pierlert, James H.

    1977-01-01

    Current activity intended to lead to energy conservation measures in building codes and standards is reviewed by members of the Office of Building Standards and Codes Services of the National Bureau of Standards. For journal availability see HE 508 931. (LBH)

  17. A second chance for old buildings

    NARCIS (Netherlands)

    Geraedts, Rob P.; van der Voordt, Theo; Foliente, G; Luetzkendorf, T; Newton, P; Paevere, P

    2008-01-01

    In the Netherlands, both the office market and housing market show a mismatch between supply and demand, quantitatively and qualitatively. In 2007 almost 14% of all offices are vacant, i.e. 5.9 million square meters. At the same time we see a shortage of about 1 million dwellings. A building must be

  18. Percieved control over indoor climate and its impact on Dutch office workers

    NARCIS (Netherlands)

    Boerstra, A.C.; Loomans, M.G.L.C.; Hensen, J.L.M.; Loomans, M.G.L.C.; Kulve, te M.

    2015-01-01

    A field study was conducted in nine modern office buildings in the Netherlands. The study focused on perceived control over indoor climate and its impact on satisfaction of building occupants, the incidence of building related (SBS) symptoms and self-assessed performance. The study involved a

  19. Comparison between lighting performance of a virtual natural lighting solutions prototype and a real window based on computer simulation

    Directory of Open Access Journals (Sweden)

    R.A. Mangkuto

    2014-12-01

    Full Text Available This article discusses the measurement and simulation of a first generation prototype of Virtual Natural Lighting Solutions (VNLS, which are systems that can artificially provide natural lighting as well as a realistic outside view, with properties comparable to those of real windows and skylights. Examples of employing Radiance as a simulation tool to predict the lighting performance of such solutions are shown, for a particular case study of a VNLS prototype displaying variations of a simplified view of overcast, clear, and partly cloudy skies. Measurement and simulation were conducted to evaluate the illuminance distribution on workplane level. The key point of this study is to show that simulations can be used to compare an actual VNLS prototype with a hypothetical real window under the same sky scenes, which was physically not possible, since the test room was not located at the building׳s façade. It is found that the investigated prototype yields a less rapidly drop illuminance distribution and a larger average illuminance than the corresponding real window, under the overcast (52 lx compared to 28 lx and partly cloudy (102 lx compared to 80 lx sky scenes. Under the clear sky scene, the real window yields a larger average illuminance (97 lx compared to the prototype (71 lx, due to the influence of direct sunlight.

  20. After-hours Power Status of Office Equipment in the USA

    Energy Technology Data Exchange (ETDEWEB)

    Webber, Carrie A.; Roberson, Judy A.; McWhinney, Marla C.; Brown,Richard E.; Pinckard, Margaret J.; Busch, John F.

    2005-10-13

    Office equipment is expected to be the fastest-growingsegment of commercial energy use over the next 20 years, yet many aspectsof office equipment energy use are poorly understood. User behavior, suchas turning off devices at night or enabling power management, influencesenergy use to a great extent. The computing environment also plays a roleboth in influencing user behavior and in the success of power management.Information about turn-off rates and power management rates for officeequipment was collected through a series of after-hours audits incommercial buildings. Sixteen businesses were recruited, includingoffices (small, medium and large offices in a variety of industries),schools, and medical buildings in California, Georgia, and Pennsylvania.The types and power states of office equipment found in these buildingswere recorded and analyzed. This article presents these data forcomputers, monitors, printers, copiers, fax machines, scanners andmulti-function devices. These data can be used to improve estimates ofboth energy consumption for these devices and savings from energyconservation efforts.