WorldWideScience

Sample records for prototype imp free-electron

  1. The ETA-II linear induction accelerator and IMP wiggler: A high-average-power millimeter-wave free-electron-laser for plasma heating

    International Nuclear Information System (INIS)

    Allen, S.L.; Scharlemann, E.T.

    1992-05-01

    We have constructed a 140-GHz free-electron laser to generate high-average-power microwaves for heating the MTX tokamak plasma. A 5.5-m steady-state wiggler (intense Microwave Prototype-IMP) has been installed at the end of the upgraded 60-cell ETA-II accelerator, and is configured as an FEL amplifier for the output of a 140-GHz long-pulse gyrotron. Improvements in the ETA-II accelerator include a multicable-feed power distribution network, better magnetic alignment using a stretched-wire alignment technique (SWAT). and a computerized tuning algorithm that directly minimizes the transverse sweep (corkscrew motion) of the electron beam. The upgrades were first tested on the 20-cell, 3-MeV front end of ETA-II and resulted in greatly improved energy flatness and reduced corkscrew motion. The upgrades were then incorporated into the full 60-cell configuration of ETA-II, along with modifications to allow operation in 50-pulse bursts at pulse repetition frequencies up to 5 kHz. The pulse power modifications were developed and tested on the High Average Power Test Stand (HAPTS), and have significantly reduced the voltage and timing jitter of the MAG 1D magnetic pulse compressors. The 2-3 kA. 6-7 MeV beam from ETA-II is transported to the IMP wiggler, which has been reconfigured as a laced wiggler, with both permanent magnets and electromagnets, for high magnetic field operation. Tapering of the wiggler magnetic field is completely computer controlled and can be optimized based on the output power. The microwaves from the FEL are transmitted to the MTX tokamak by a windowless quasi-optical microwave transmission system. Experiments at MTX are focused on studies of electron-cyclotron-resonance heating (ECRH) of the plasma. We summarize here the accelerator and pulse power modifications, and describe the status of ETA-II, IMP, and MTX operations

  2. The ETA-II linear induction accelerator and IMP wiggler: A high-average-power millimeter-wave free-electron laser for plasma heating

    International Nuclear Information System (INIS)

    Allen, S.L.; Scharlemann, E.T.

    1993-01-01

    The authors have constructed a 140-GHz free-electron laser to generate high-average-power microwaves for heating the MTX tokamak plasma. A 5.5-m steady-state wiggler (Intense Microwave, Prototype-IMP) has been installed at the end of the upgraded 60-cell ETA-II accelerator, and is configured as an FEL amplifier for the output of a 140-GHz long-pulse gyrotron. Improvements in the ETA-II accelerator include a multicable-feed power distribution network, better magnetic alignment using a stretched-wire alignment technique (SWAT), and a computerized tuning algorithm that directly minimizes the transverse sweep (corkscrew motion) of the electron beam. The upgrades were first tested on the 20-cell, 3-MeV front end of ETA-II and resulted in greatly improved energy flatness and reduced corkscrew motion. The upgrades were then incorporated into the full 60-cell configuration of ETA-II, along with modifications to allow operation in 50-pulse bursts at pulse repetition frequencies up to 5 kHz. The pulse power modifications were developed and tested on the High Average Power Test Stand (HAPTS), and have significantly reduced the voltage and timing jitter of the MAG 1D magnetic pulse compressors. The 2-3 kA, 6-7 MeV beam from ETA-II is transported to the IMP wiggler, which has been reconfigured as a laced wiggler, with both permanent magnets and electromagnets, for high magnetic field operation. Tapering of the wiggler magnetic field is completely computer controlled and can be optimized based on the output power. The microwaves from the FEL are transmitted to the MTX tokamak by a windowless quasi-optical microwave transmission system. Experiments at MTX are focused on studies of electron-cyclotron-resonance heating (ECRH) of the plasma. The authors summarize here the accelerator and pulse power modifications, and describe the status of ETA-II, IMP, and MTX operations

  3. Control system for JAERI Free Electron Laser

    International Nuclear Information System (INIS)

    Sugimoto, Masayoshi

    1992-01-01

    A control system comprising of the personal computers network and the CAMAC stations for the JAERI Free Electron Laser is designed and is in the development stage. It controls the equipment and analyzes the electron and optical beam experiments. The concept and the prototype of the control system are described. (author)

  4. Research on heightening quality of free electron laser using superconducting linear accelerator

    International Nuclear Information System (INIS)

    Minehara, Eisuke

    1996-01-01

    In this paper, the superconducting high frequency linear accelerator technology using low temperature superconductor is introduced, and its application to the heightening of quality of free electron laser is discussed. The high frequency application of superconductivity is a relatively new technology, and the first superconducting high frequency linear accelerator was made at the middle of 1960s. The invention of free electron laser and the development so far are described. In free electron laser, the variation of wavelength, high efficiency and high power output are possible as compared with conventional type lasers. The price and the size are two demerits of free electron laser that remain to the last. In Japan Atomic Energy Research Institute, the adjustment experiment is carried out for the prototype free electron laser. About this prototype, injection system, superconducting accelerator, helium refrigerator, whole solid element high frequency power source, control system, electron beam transport system, undulator system and optical resonator are described. The application of high mean power output free electron laser and its future are discussed. (K.I.)

  5. Tangiplay: prototyping tangible electronic games

    OpenAIRE

    Boileau, Jason

    2010-01-01

    Tangible electronic games currently exist in research laboratories around the world but have yet to transition to the commercial sector. The development process of a tangible electronic game is one of the factors preventing progression, as it requires much time and money. Prototyping tools for tangible hardware and software development are becoming more available but are targeted to programmers and technically trained developers. Paper prototyping board and video games is a proven and rapid m...

  6. 6. Seminar of the IIE-ININ-IMP on technological specialties. Topic 9: electronics, instrumentation and control

    International Nuclear Information System (INIS)

    1992-01-01

    The document includes 10 papers presented at the 6. Seminar of the IIE-ININ-IMP on technological specialities in the field of electronics, instrumentation and control. (Topic 9). From these, 4 papers were in INIS subject scope and a separate abstract was prepared for each of them

  7. ISEE/IMP Observations of simultaneous upstream ion events

    International Nuclear Information System (INIS)

    Mitchel, D.G.; Roelof, E.C.; Sanderson, T.R.; Reinhard, R.; Wenzel, K.

    1983-01-01

    Propagation of upstream energetic (50--200 keV) ions is analyzed in sixteen events observed simulataneously by solid state detectors on ISEE 3 at approx.200 R/sub E/ and on IMP 8 at approx.35 R/sub E/ from the earth. Conclusions are based on comparisons of the pitch angle distributions observed at the two spacecraft and transformed into the solar wind frame. They are beamlike at ISEE 3 and are confined to the outward hemisphere. When IMP 8 is furtherest from the bow shock, they are also usually beamlike, or hemispheric. However, when IMP 8 is closer to the bow shock, pancakelike distributions are observed. This systematic variation in the IMP 8 pitch angle distributions delimits a scattering region l< or approx. =14 R/sub E/ upstream of the earth's bow shock (l measured along the interplanetary magnetic field) that dominates ion propagation, influences the global distribution of fluxes in the foreshock, and may play a role in acceleration of the ions. When IMP 8 is beyond lapprox.15 R/sub E/, the propagation appears to be essentially scatter-free between IMP 8 and ISEE 3; this is deduced from the absence of earthward fluxes at IMP 8 as well as the tendency for the spin-averaged fluxes to be comparable at the two spacecraft

  8. Cell-free synthetic biology for in vitro prototype engineering.

    Science.gov (United States)

    Moore, Simon J; MacDonald, James T; Freemont, Paul S

    2017-06-15

    Cell-free transcription-translation is an expanding field in synthetic biology as a rapid prototyping platform for blueprinting the design of synthetic biological devices. Exemplar efforts include translation of prototype designs into medical test kits for on-site identification of viruses (Zika and Ebola), while gene circuit cascades can be tested, debugged and re-designed within rapid turnover times. Coupled with mathematical modelling, this discipline lends itself towards the precision engineering of new synthetic life. The next stages of cell-free look set to unlock new microbial hosts that remain slow to engineer and unsuited to rapid iterative design cycles. It is hoped that the development of such systems will provide new tools to aid the transition from cell-free prototype designs to functioning synthetic genetic circuits and engineered natural product pathways in living cells. © 2017 The Author(s).

  9. IMP and NLHIAL annual report (1999)

    International Nuclear Information System (INIS)

    2000-07-01

    In the year of 1999, HIRFL-CSR, a new project proposed by IMP and NLHIAL was approved by the Chinese government, and started to build up. The research result, and activities of IMP and NLHIAL during the year of 1999 was summarized. The contents were divided into two parts. Part A presented by National Laboratory of Heavy Ion Accelerator in Lanzhou (NLHIAL). It includes experimental nuclear physics and nuclear chemistry, application of heavy ion physics, accelerator and the others. Part B presented by Institute of Modern Physics. It includes theoretical nuclear physics, experimental nuclear physics and nuclear chemistry. Application of heavy ion physics and nuclear technique, computer technique and electronics, accelerator and the others

  10. A novel small-period wiggler for free-electron lasers

    International Nuclear Information System (INIS)

    Feng Bibo; Wang Mingchang; Wang Zhijiang

    1992-01-01

    A novel small-period wiggler configuration constructed by sheet of bifilar-helix with ferro-core for free-electron lasers is proposed. The performance characteristics of the wiggler prototype with 10 mm period are measured. The field as high as 500 G to 1 kG have been obtained. The amplifier designs for operation at 190 GHz using modest electron beam energies in the range of 400-500 keV are presented

  11. The general particle tracer code applied to the fusion free-electron maser

    NARCIS (Netherlands)

    de Loos, M. J.; van der Geer, S. B.; van der Geer, C. A. J.; Verhoeven, A. G. A.; Urbanus, W. H.

    1998-01-01

    The fusion Free-Electron Maser (FEM) is the prototype of a high power, electrostatic mm-wave source, tunable in the range 130-260 GHz. In order to achieve a high overall efficiency, the charge and energy of the spent electron beam, i.e. the beam which leaves the undulator after interaction with the

  12. Prototype electronic stethoscope vs. conventional stethoscope for auscultation of heart sounds.

    Science.gov (United States)

    Kelmenson, Daniel A; Heath, Janae K; Ball, Stephanie A; Kaafarani, Haytham M A; Baker, Elisabeth M; Yeh, Daniel D; Bittner, Edward A; Eikermann, Matthias; Lee, Jarone

    2014-08-01

    In an effort to decrease the spread of hospital-acquired infections, many hospitals currently use disposable plastic stethoscopes in patient rooms. As an alternative, this study examines a prototype electronic stethoscope that does not break the isolation barrier between clinician and patient and may also improve the diagnostic accuracy of the stethoscope exam. This study aimed to investigate whether the new prototype electronic stethoscope improved auscultation of heart sounds compared to the standard conventional isolation stethoscope. In a controlled, non-blinded, cross-over study, clinicians were randomized to identify heart sounds with both the prototype electronic stethoscope and a conventional stethoscope. The primary outcome was the score on a 10-question heart sound identification test. In total, 41 clinicians completed the study. Subjects performed significantly better in the identification of heart sounds when using the prototype electronic stethoscope (median = 9 [7-10] vs. 8 [6-9] points, p value prototype electronic stethoscope. Clinicians using a new prototype electronic stethoscope achieved greater accuracy in identification of heart sounds and also universally favoured the new device, compared to the conventional stethoscope.

  13. Global Molecular Epidemiology of IMP-Producing Enterobacteriaceae.

    Science.gov (United States)

    Matsumura, Yasufumi; Peirano, Gisele; Motyl, Mary R; Adams, Mark D; Chen, Liang; Kreiswirth, Barry; DeVinney, Rebekah; Pitout, Johann D D

    2017-04-01

    International data on the molecular epidemiology of Enterobacteriaceae with IMP carbapenemases are lacking. We performed short-read (Illumina) whole-genome sequencing on a global collection of 38 IMP-producing clinical Enterobacteriaceae (2008 to 2014). IMP-producing Enterobacteriaceae (7 varieties within 11 class 1 integrons) were mainly present in the South Pacific and Asia. Specific bla IMP -containing integrons (In809 with bla IMP-4 , In722 with bla IMP-6 , and In687 with bla IMP-14 ) were circulating among different bacteria in countries such as Australia, Japan, and Thailand. In1312 with bla IMP-1 was present in Klebsiella pneumoniae from Japan and Citrobacter freundii from Brazil. Klebsiella pneumoniae ( n = 22) was the most common species; clonal complex 14 (CC14) from Philippines and Japan was the most common clone and contained In1310 with bla IMP-26 and In1321 with bla IMP-6 The Enterobacter cloacae complex ( n = 9) consisted of Enterobacter hormaechei and E. cloacae cluster III. CC78 (from Taiwan) containing In73 with bla IMP-8 was the most common clone among the E. cloacae complex. This study highlights the importance of surveillance programs using the latest molecular techniques for providing insight into the characteristics and global distribution of Enterobacteriaceae with bla IMP genes. Copyright © 2017 American Society for Microbiology.

  14. Oncofetal protein IMP3, a new cancer biomarker.

    Science.gov (United States)

    Gong, Yuna; Woda, Bruce A; Jiang, Zhong

    2014-05-01

    IMP3 is a member of a family of RNA-binding proteins that consists of IMP1, IMP2 and IMP3. These proteins contain 2 RNA recognition motifs and 4 K-homology domains that allow them to bind RNAs strongly and specifically. IMP3 is an oncofetal protein involved in embryogenesis and its expression is associated with a number of malignant neoplasms. IMP3 is associated with aggressive and advanced cancers and is specifically expressed in malignant tumors but is not found in adjacent benign tissues. Moreover, in vitro studies have shown that IMP3 promotes tumor cell proliferation, adhesion, and invasion. This review focuses on the studies of IMP3 expression in different cancers and emphasizes the potential utility of IMP3 in routine surgical pathology practice. We also discuss IMP3 as a prognostic biomarker for cancer patients' outcomes.

  15. Stable confinement of toroidal electron plasma in an internal conductor device Prototype-Ring Trap

    International Nuclear Information System (INIS)

    Saitoh, H.; Yoshida, Z.; Watanabe, S.

    2005-01-01

    A pure electron plasma has been produced in an internal conductor device Prototype-Ring Trap (Proto-RT). The temporal evolution of the electron plasma was investigated by the measurement of electrostatic fluctuations. Stable confinement was realized when the potential profile adjusted to match the magnetic surfaces. The confinement time varies as a function of the magnetic field strength and the neutral gas pressure, and is comparable to the diffusion time of electrons determined by the classical collisions with neutral gas. Although the addition of a toroidal magnetic field stabilized the electrostatic fluctuation of the plasma, the effects of the magnetic shear shortened the stable confinement time, possibly because of the obstacles of coil support structures

  16. Characteristics of the magnetospheric boundary layer and magnetopause layer as observed by Imp 6

    International Nuclear Information System (INIS)

    Eastman, T.E.; Hones, E.W. Jr.

    1979-01-01

    Imp 6 observations of the low-latitude magnetospheric boundary layer indicate that the plasma within it is supplied primarily by direct entry of magnetosheath plasma across the magnetopause layer. We define the magnetopause layer as the current layer (separating the magnetosheath from the boundary layer) through which the magnetic field shifts in direction. High temporal resolution (3-s average) data reveal that in a majority of Imp 6 magnetopause crossing, no distinct changes in electron density or energry spectra are observed at the magne opause layer. In all Imp 6 crossings, some magnetosheathlike plasma is observed earthward of the magnetopause layer, implying the existence of a boundary layer. Boundary layer electron energy spectra are often virtually indistinguishable from the adjacent magnetosheath spectra. Low-latitude boundary layer bulk plasma flow as observed by Imp 6 almost always has an antisunward component and often has a significant cross-field component. The boundary layer thickness is highly variable and is generally much larger than the magnetopause layer thickness. Energetic electron pitch angle distributions indicate that the low-latitude boundary layers is normally on closed field lines. We conclude that diffusive as well as nondiffusive processes probably contribute to the entry of magnetosheath plasma into the boundary layer

  17. IMP - INTEGRATED MISSION PROGRAM

    Science.gov (United States)

    Dauro, V. A.

    1994-01-01

    FORTRAN 77 for DEC VAX series computers running VMS. The optional TEKPLOT plotting module requires the VAX TEK library. The standard distribution medium for this program is a 9track 1600 BPI magnetic tape in DEC VAX BACKUP format. It is also available on a TK50 tape cartridge in DEC VAX BACKUP format. An electronic copy of the documentation is included on the distribution medium. Although IMP was originally developed in the 1970s, the author has continued to use and refine it. This version was updated in 1992. DEC, TK50, VAX, and VMS are trademarks of Digital Equipment Corporation.

  18. Impétigo ampolloso

    OpenAIRE

    Alma Delfina Pérez-De la O; María Teresa García Romero

    2017-01-01

    El impétigo es la enfermedad infecto-contagiosa más común en la piel.1 Existen dos tipos: no ampolloso, que es el más frecuente, y ampolloso. Es causado principalmente por Streptococcus pyogenes (Streptococcus β-hemolítico del grupo A) y Staphylococcus aureus. El impétigo no ampolloso es producido principalmente por S. pyogenes y se caracteriza por vesículas pequeñas que rápidamente se rompen y originan un exudado que al secarse forma costras melicéricas. El impétigo ampolloso siempre es caus...

  19. Characteristics and management of Enterobacteriaceae harboring IMP-4 or IMP-8 carbapenemase in a tertiary hospital.

    Science.gov (United States)

    Pang, Feng; Jia, Xiu-Qin; Song, Zhen-Zhu; Li, Yan-Hua; Wang, Bin; Zhao, Qi-Gang; Wang, Chuan-Xin; Zhang, Yi; Wang, Le-Xin

    2016-03-01

    The emergence of Enterobacteriaceae harboring IMP-4 or IMP-8 carbapenemases is rare. We report an occurrence of Enterobacteriaceae harboring IMP-4 or IMP-8 carbapenemases in a Chinese tertiary care hospital from November 2010 to December 2012. The clinical characteristics of 30 patients were described. The genetic relationship of isolates was determined by pulsed-field gel electrophoresis (PFGE). Carbapenemases were detected by modified Hodge test (MHT) and polymerase chain reactions (PCRs). Amplicons were sequenced and blasted to determine the genotype. Most infected patients were from intensive care unit and had complex and serious underlying illnesses requiring mechanical ventilation. PFGE revealed that Klebsiella pneumoniae showed two major PFGE types. Two Klebsiella oxytoca had an indistinguishable PFGE pattern, while four Enterobacter cloacae were different strains. The sequencing studies showed Enterobacteriaceae harboring IMP-4 or IMP-8 carbapenemase in the 23 infected patients. The majority of patients had infections with the carbapenemase-producing Enterobacteriaceae (CPE) strain, most were successfully treated with a range of antibiotics and discharged. It is important to maintain a high index of suspicion to screen for carbapenemase-producing Enterobacteriaceae strains. Rapid identification of these strains and implementation of stringent procedures are the key to prevent major outbreaks in a hospital setting.

  20. IMP: Using microsat technology to support engineering research inside of the International Space Station

    Science.gov (United States)

    Carroll, Kieran A.

    2000-01-01

    This paper describes an International Space Station (ISS) experiment-support facility being developed by Dynacon for the Canadian Space Agency (CSA), based on microsatellite technology. The facility is called the ``Intravehicular Maneuverable Platform,'' or IMP. The core of IMP is a small, free-floating platform (or ``bus'') deployed inside one of the pressurized crew modules of ISS. Exchangeable experimental payloads can then be mounted to the IMP bus, in order to carry out engineering development or demonstration tests, or microgravity science experiments: the bus provides these payloads with services typical of a standard satellite bus (power, attitude control, etc.). The IMP facility takes advantage of unique features of the ISS, such as the Shuttle-based logistics system and the continuous availability of crew members, to greatly reduce the expense of carrying out space engineering experiments. Further cost reduction has been made possible by incorporating technology that Dynacon has developed for use in a current microsatellite mission. Numerous potential payloads for IMP have been identified, and the first of these (a flexible satellite control experiment) is under development by Dynacon and the University of Toronto's Institute for Aerospace Studies, for the CSA. .

  1. Fast solar electrons, interplanetary plasma and km-wave type-III radio bursts observed from the IMP-6 spacecraft

    International Nuclear Information System (INIS)

    Alvarez, H.; Lin, R.P.

    1975-01-01

    IMP-6 spacecraft observations of low frequency radio emission, fast electrons, and solar wind plasma are used to examine the dynamics of the fast electron streams which generate solar type-III radio bursts. Of twenty solar electron events observed between April 1971 and August 1972, four were found to be amenable to detailed analysis. Observations of the direction of arrival of the radio emission at different frequencies were combined with the solar wind density and velocity measurements at 1 AU to define an Archimedean spiral trajectory for the radio burst exciter. The propagation characteristics of the exciter and of the fast electrons observed at 1 AU were then compared. It is found that: (1) the fast electrons excite the radio emission at the second harmonic; (2) the total distance travelled by the electrons was between 30 and 70% longer than the length of the smooth spiral defined by the radio observations; (3) this additional distance travelled is the result of scattering of the electrons in the interplanetary medium; (4) the observations are consistent with negligible true energy loss by the fast electrons.(Auth.)

  2. Actuator prototype system by voice commands using free software

    Directory of Open Access Journals (Sweden)

    Jaime Andrango

    2016-06-01

    Full Text Available This prototype system is a software application that through the use of techniques of digital signal processing, extracts information from the user's speech, which is then used to manage the on/off actuator on a peripheral computer when vowels are pronounced. The method applies spectral differences. The application uses the parallel port as actuator, with the information recorded in the memory address 378H. This prototype was developed using free software tools for its versatility and dynamism, and to allow other researchers to base on it for further studies.

  3. RNA-binding IMPs promote cell adhesion and invadopodia formation

    DEFF Research Database (Denmark)

    Vikesaa, Jonas; Hansen, Thomas V O; Jønson, Lars

    2006-01-01

    Oncofetal RNA-binding IMPs have been implicated in mRNA localization, nuclear export, turnover and translational control. To depict the cellular actions of IMPs, we performed a loss-of-function analysis, which showed that IMPs are necessary for proper cell adhesion, cytoplasmic spreading and inva......Oncofetal RNA-binding IMPs have been implicated in mRNA localization, nuclear export, turnover and translational control. To depict the cellular actions of IMPs, we performed a loss-of-function analysis, which showed that IMPs are necessary for proper cell adhesion, cytoplasmic spreading...... and invadopodia formation. Loss of IMPs was associated with a coordinate downregulation of mRNAs encoding extracellular matrix and adhesion proteins. The transcripts were present in IMP RNP granules, implying that IMPs were directly involved in the post-transcriptional control of the transcripts. In particular......-mediated invadopodia formation. Taken together, our results indicate that RNA-binding proteins exert profound effects on cellular adhesion and invasion during development and cancer formation....

  4. The Alice dimuon trigger: overview and electronics prototypes

    International Nuclear Information System (INIS)

    Arnaldi, R.; Baldit, A.; Barret, V.; Bastid, N.

    2000-01-01

    ALICE is the LHC experiment (2005) dedicated to the study of heavy ion collisions. Amongst the ALICE sub-detectors, the muon spectrometer will investigate the dimuon production from heavy resonance (J/ψ,γ) decays, which is believed to be a promising signature of the QGP (quark Gluon Plasma) formation. For maximum efficiency of the spectrometer, a dedicated dimuon trigger is presently built. The detector part itself is based on RPCs operated in streamer mode and is the topic of another contribution to this conference. This paper gives the principle and the simulated performances of the trigger and is also focussed on the description of the electronics prototypes and future developments. The RPCs are read-out by X and Y orthogonal strips: the front-end chips are presently developed. The signals are sent to the trigger electronics which basically performs a pt cut on the tracks to reduce the background. A prototype of fast (decision time 200 ns) programmable electronics working in a pipelined mode at 40 MHz has been built and tested. This prototype handles simultaneously 160 digital information from the strips. The tests of the trigger card have required the construction of a pattern generator (160 bits at 40 MHz). (author)

  5. Insight into stereochemistry of a new IMP allelic variant (IMP-55) metallo-β-lactamase identified in a clinical strain of Acinetobacter baumannii.

    Science.gov (United States)

    Shakibaie, Mohammad Reza; Azizi, Omid; Shahcheraghi, Fereshteh

    2017-07-01

    Metallo-β-lactamases (MBLs) such as IMPs are broad-spectrum β-lactamases that inactivate virtually all β-lactam antibiotics including carbapenems. In this study, we investigated the hydrolytic activity, phylogenetic relationship, three dimensional (3D) structure including zinc binding motif of a new IMP variant (IMP-55) identified in a clinical strain of Acinetobacter baumannii (AB). AB strain 56 was isolated from an adult ICU of a teaching hospital in Kerman, Iran. It exhibited MIC 32μg/ml to imipenem and showed MBL activity. Hydrolytic property of the MBL enzyme was measured phenotypically. Presence of bla IMP gene encoded by class 1 integrons was detected by PCR-sequencing. Phylogenetic tree of IMP protein was constructed using the Unweighted Pair Group Method with Arithmetic Mean (UPGMA) and 3D model including zinc binding motif was predicted by bioinformatics softwares. Analysis of IMP sequence led to the identification of a novel IMP-type designated as IMP-55 (GenBank: KU299753.1; UniprotKB: A0A0S2MTX2). Impact in term of hydrolytic activity compared to the closest variants suggested efficient imipenem hydrolysis by this enzyme. Evolutionary distance matrix assessment indicated that IMP-55 protein is not closely related to other A. baumannii IMPs, however, shared 98% homology with Escherichia coli IMP-30 (UniprotKB: A0A0C5PJR0) and Pseudomonas aeruginosa IMP-1 (UniprotKB: Q19KT1). It consisted of five α-helices, ten β-sheets and six loops. A monovalent zinc ion attached to core of enzyme via His95, His97, His157 and Cys176. Multiple amino acid sequence alignments and mutational trajectory with reported IMPs showed 4 amino acid substitutions at positions 12(Phe→Ile), 31(Asp→Glu), 172(Leu→Phe) and 185(Asn→Lys). We suggest that the pleiotropic effect of mutations due to frequent administration of imipenem is responsible for emergence of new IMP variant in our hospitals. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Front-end Electronics for Unattended Measurement (FEUM). Prototype Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Conrad, Ryan C.; Morris, Scott J.; Smith, Leon E.; Keller, Daniel T.

    2015-09-16

    The IAEA has requested that PNNL perform an initial set of tests on front-end electronics for unattended measurement (FEUM) prototypes. The FEUM prototype test plan details the tests to be performed, the criteria for evaluation, and the procedures used to execute the tests.

  7. Free electron laser

    International Nuclear Information System (INIS)

    Ortega, J.M.; Billardon, M.

    1986-01-01

    Operation principle of a laser and an oscillator are recalled together with the klystron one. In the free electron laser, electrons go through an undulator or an optical klystron. Principles of the last one are given. The two distinct ways of producing coherent radiation with an undulator and an optical klystron are presented. The first one is the use of the free electron laser, the second is to make use of the spontaneous emission generation (harmonics generation). The different current types of free electron lasers are presented (Stanford, Los Alamos, Aco at Orsay). Prospects and applications are given in conclusion [fr

  8. Oncofetal Protein IMP3: A Novel Molecular Marker That Predicts Metastasis of Papillary and Chromophobe Renal Cell Carcinomas

    Science.gov (United States)

    Jiang, Zhong; Lohse, Christine M.; Chu, Peigou G.; Wu, Chin-Lee; Woda, Bruce A.; Rock, Kenneth L.; Kwon, Eugene D.

    2009-01-01

    BACKGROUND Whether an oncofetal protein, IMP3, can serve as a prognostic biomarker to predict metastasis for patients with localized papillary and chromophobe subtypes of renal cell carcinomas (RCCs) was investigated. METHODS The expression of IMP3 in 334 patients with primary papillary and chromophobe RCC from multiple medical centers was evaluated by immunohistochemistry. The 317 patients with localized papillary and chromophobe RCCs were further evaluated for outcome analyses. RESULTS IMP3 was significantly increased in a subset of localized papillary and chromophobe RCCs that subsequently metastasized. Patients with localized IMP3-positive tumors (n = 33; 10%) were over 10 times more likely to metastasize (risk ratio [RR], 11.38; 95% confidence interval [CI], 5.40–23.96; P <.001) and were nearly twice as likely to die (RR, 1.91; 95% CI, 1.13–3.22; P =.016) compared with patients with localized IMP3 negative tumors. The 5-year metastasis-free and overall survival rates were 64% and 58% for patients with IMP3-positive localized papillary and chromophobe RCCs compared with 98% and 85% for patients with IMP3 negative tumors, respectively. In multivariable analysis adjusting for the TNM stage and nuclear grade, patients with IMP3-positive tumors were still over 10 times more likely to progress to distant metastasis (RR, 13.45; 95% CI, 6.00–30.14; P <.001) and were still nearly twice as likely die (RR, 1.95; 95% CI, 1.15–3.31; P =.013) compared with patients with IMP3-negative tumors. CONCLUSIONS IMP3 is an independent prognostic biomarker that can be used to identify a subgroup of patients with localized papillary and chromophobe RCC who are at high risk for developing distant metastasis. PMID:18412154

  9. Coherent harmonics of a Free Electron Laser obtained by the injection of harmonics produced in gas on the SCSS prototype accelerator

    International Nuclear Information System (INIS)

    Lambert, G.

    2008-02-01

    Today, single-pass Free Electron Lasers (FELs) allow the structure of matter to be studied in the femtosecond domain. Yet, even if the produced radiation, the so-called Self Amplified Spontaneous Emission (SASE) is highly bright, the longitudinal coherence is partial; the spectral and temporal profiles are composed of a series of peaks, called 'spikes', and present important statistical fluctuations. We demonstrate here the strong and coherent amplification of the 5. harmonic of a Ti: Sa laser (800 nm, 10 Hz, 100 fs) generated in a gas cell, i.e. 160 nm, and seeded in a FEL. This spectacular phenomenon is associated to the generation of intense and coherent Non Linear Harmonics (NLH) at 54 nm and 32 nm. The experiment has been carried out on the SCSS (SPring-8 Compact SASE Source, Japan) Prototype Accelerator. This facility is mainly based on a thermionic cathode electron gun, a LINAC and an in-vacuum undulator (2 sections of 4.5 m length), in which the external harmonic source is overlapped transversally, spectrally and temporally with the electron beam (150 MeV, 10 Hz, 1 ps). With only one undulator section, the 160 nm seeded emission achieves three orders of magnitude higher intensity than the un-seeded one, and presents a quasi perfect Gaussian shape in the spectral distribution. Moreover, the FEL saturation length is twice smaller. In view of the low seed level required, such amplification associated to NLH schemes would allow the generation of fully coherent soft X-ray radiations down to the 'water window'. (author)

  10. Prototype of industrial electrons accelerator

    International Nuclear Information System (INIS)

    Lopez, V.H.; Valdovinos, A.M.

    1992-01-01

    The interest and the necessity of Mexico's industry in the use of irradiation process has been increased in the last years. As examples are the irradiation of combustion gases (elimination of NO x and SO 2 ) and the polymer cross-linking between others. At present time at least twelve enterprises require immediately of them which have been contacted by electron accelerators suppliers of foreign countries. The first project step consisted in to identify the electrons accelerator type that in can be constructed in Mexico with the major number of possible equipment, instruments, components and acquisition materials local and useful for the major number of users. the characteristics of the accelerator prototype are: accelerator type transformer with multiple secondary insulated and rectifier circuits with a potential of 0.8 MV of voltage, the second step it consisted in an economic study that permitted to demonstrate the economic feasibility of its construction. (Author)

  11. The ALICE Dimuon Trigger Overview and Electronics Prototypes

    CERN Document Server

    Arnaldi, R; Barret, V; Bastid, N; Blanchard, G; Chiavassa, E; Cortese, P; Crochet, Philippe; Dellacasa, G; De Marco, N; Drancourt, C; Dupieux, P; Espagnon, B; Fargeix, J; Ferretti, A; Gallio, M; Genoux-Lubain, A; Lamoine, L; Lefèvre, F; Luquin, Lionel; Manso, F; Métivier, V; Musso, A; Oppedisano, C; Piccotti, A; Royer, L; Roig, O; Rosnet, P; Scalas, E; Scomparin, E; Vercellin, Ermanno

    2000-01-01

    Presentation made at RPC99 and submitted to NIM ALICE is the LHC experiment (2005) dedicated to the study of heavy ion collisions. Amongst the ALICE sub-detectors, the muon spectrometer will investigate the dimuon production from heavy resonance (J/psi, Gamma) decays, which is believed to be a promising signature of the QGP (Quark Gluon Plasma) formation.For maximum efficiency of the spectrometer, a dedicated dimuon trigger is presently built. The detector partis itself based on RPCs operated in streamer mode and is the topic of another contribution to this conference. This paper gives the principle and the simulated performances of the trigger and is also focussed on the description of the electronics prototypes and future developments. The RPCs are read-out by X and Y orthogonal strips: the front-end chips are presently developed. The signals are sent to the trigger electronics which basically performs a pt cut on the tracks to reduce the background. A prototype of fast (decision time 200 ns) programmable e...

  12. XUV free-electron laser-based projection lithography systems

    Energy Technology Data Exchange (ETDEWEB)

    Newnam, B.E.

    1990-01-01

    Free-electron laser sources, driven by rf-linear accelerators, have the potential to operate in the extreme ultraviolet (XUV) spectral range with more than sufficient average power for high-volume projection lithography. For XUV wavelengths from 100 nm to 4 nm, such sources will enable the resolution limit of optical projection lithography to be extended from 0.25 {mu}m to 0.05{mu}m and with an adequate total depth of focus (1 to 2 {mu}m). Recent developments of a photoinjector of very bright electron beams, high-precision magnetic undulators, and ring-resonator cavities raise our confidence that FEL operation below 100 nm is ready for prototype demonstration. We address the motivation for an XUV FEL source for commercial microcircuit production and its integration into a lithographic system, include reflecting reduction masks, reflecting XUV projection optics and alignment systems, and surface-imaging photoresists. 52 refs., 7 figs.

  13. Palm Power Free-Piston Stirling Engine Control Electronics

    Science.gov (United States)

    Keiter, Douglas E.; Holliday, Ezekiel

    2007-01-01

    A prototype 35We, JP-8 fueled, soldier-wearable power system for the DARPA Palm Power program has been developed and tested by Sunpower. A hermetically-sealed 42We Sunpower Free-Piston Stirling Engine (FPSE) with integral linear alternator is the prime mover for this system. To maximize system efficiency over a broad range of output power, a non-dissipative, highly efficient electronic control system which modulates engine output power by varying piston stroke and converts the AC output voltage of the FPSE into 28Vdc for the Palm Power end user, has been designed and demonstrated as an integral component of the Palm Power system. This paper reviews the current status and progress made in developing the control electronics for the Palm Power system, in addition to describing the operation and demonstrated performance of the engine controller in the context of the current JP-8 fueled Palm Power system.

  14. Digital and Analog Electronics for an autonomous, deep-sea, Gamma Ray Burst Neutrino prototype detector

    Directory of Open Access Journals (Sweden)

    Manolopoulos K.

    2016-01-01

    Full Text Available GRBNeT is a Gamma Ray Burst Neutrino Telescope made of autonomously operated arrays of deep-sea light detectors, anchored to the sea-bed without any cabled connection to the shore. This paper presents the digital and analog electronics that we have designed and developed for the GRBNeT prototype. We describe the requirements for these electronics and present their design and functionality. We present low-power analog electronics for the PMTs utilized in the GRBNeT prototype and the FPGA based digital system for data selection and storage. We conclude with preliminary performance measurements of the electronics systems for the GRBNeT prototype.

  15. Anatomically standardized statistical mapping of 123I-IMP SPECT in brain tumors

    International Nuclear Information System (INIS)

    Shibata, Yasushi; Akimoto, Manabu; Matsushita, Akira; Yamamoto, Tetsuya; Takano, Shingo; Matsumura, Akira

    2010-01-01

    123 I-iodoamphetamine Single Photon Emission Computed Tomography (IMP SPECT) is used to evaluate cerebral blood flow. However, application of IMP SPECT to patients with brain tumors has been rarely reported. Primary central nervous system lymphoma (PCNSL) is a rare tumor that shows delayed IMP uptake. The relatively low spatial resolution of SPECT is a clinical problem in diagnosing brain tumors. We examined anatomically standardized statistical mapping of IMP SPECT in patients with brain lesions. This study included 49 IMP SPECT images for 49 patients with brain lesions: 20 PCNSL, 1 Burkitt's lymphoma, 14 glioma, 4 other tumor, 7 inflammatory disease and 3 without any pathological diagnosis but a clinical diagnosis of PCNSL. After intravenous injection of 222 MBq of 123 I-IMP, early (15 minutes) and delayed (4 hours) images were acquired using a multi-detector SPECT machine. All SPECT data were transferred to a newly developed software program iNeurostat+ (Nihon Medi-physics). SPECT data were anatomically standardized on normal brain images. Regions of increased uptake of IMP were statistically mapped on the tomographic images of normal brain. Eighteen patients showed high uptake in the delayed IMP SPECT images (16 PCNSL, 2 unknown). Other tumor or diseases did not show high uptake of delayed IMP SPECT, so there were no false positives. Four patients with pathologically proven PCNSL showed no uptake in original IMP SPECT. These tumors were too small to detect in IMP SPECT. However, statistical mapping revealed IMP uptake in 18 of 20 pathologically verified PCNSL patients. A heterogeneous IMP uptake was seen in homogenous tumors in MRI. For patients with a hot IMP uptake, statistical mapping showed clearer uptake. IMP SPECT is a sensitive test to diagnose of PCNSL, although it produced false negative results for small posterior fossa tumor. Anatomically standardized statistical mapping is therefore considered to be a useful method for improving the diagnostic

  16. [Expression of IMP3 in osteosarcoma and its clinical significance].

    Science.gov (United States)

    Li, Kang-hua; Huang, Yue-ping; Zhang, Jun; Li, Guo-jun; Li, Si-hong

    2009-05-01

    To analyze the expressional variability of IMP3 between osteosarcoma and osteochondroma and explore its clinical significance. Paraffin sections from 68 patients with osteosarcoma and 20 patients with osteochondroma were examined for the expression of IMP3 by SP immunohistochemistry. The negative, weak positive, moderate positive and strong positive expression rates of IMP3 in 68 patients with osteosarcoma were 4.41% (3/68), 22.06% (15/68), 22.74% (19/68), 45.59% (31/68), respectively, which were significantly higher than those in 20 cases of osteochondroma tissues (P<0.01). The positive expression of IMP3 in osteosarcoma was negative correlation with the 3-year survival rate of osteosarcoma patients after the operation (P<0.01). The results suggest that IMP3 plays important roles in the tumorigenesis, progress and prognosis of osteosarcoma, and the expression of IMP3 may be an important feature of osteosarcoma.

  17. NASAwide electronic publishing system: Prototype STI electronic document distribution, stage-4 evaluation report

    Science.gov (United States)

    Tuey, Richard C.; Collins, Mary; Caswell, Pamela; Haynes, Bob; Nelson, Michael L.; Holm, Jeanne; Buquo, Lynn; Tingle, Annette; Cooper, Bill; Stiltner, Roy

    1996-01-01

    This evaluation report contains an introduction, seven chapters, and five appendices. The Introduction describes the purpose, conceptual frame work, functional description, and technical report server of the STI Electronic Document Distribution (EDD) project. Chapter 1 documents the results of the prototype STI EDD in actual operation. Chapter 2 documents each NASA center's post processing publication processes. Chapter 3 documents each center's STI software, hardware, and communications configurations. Chapter 7 documents STI EDD policy, practices, and procedures. The appendices, which arc contained in Part 2 of this document, consist of (1) STI EDD Project Plan, (2) Team members, (3) Phasing Schedules, (4) Accessing On-line Reports, and (5) Creating an HTML File and Setting Up an xTRS. In summary, Stage 4 of the NASAwide Electronic Publishing System is the final phase of its implementation through the prototyping and gradual integration of each NASA center's electronic printing systems, desktop publishing systems, and technical report servers to be able to provide to NASA's engineers, researchers, scientists, and external users the widest practicable and appropriate dissemination of information concerning its activities and the result thereof to their work stations.

  18. (123I)-IMP SPECT findings in Machado-Joseph disease

    International Nuclear Information System (INIS)

    Suzuki, Masahiko

    1997-01-01

    Single photon emission computed tomography (SPECT) with N-isopropyl-p-( 123 I)iodoamphetamine (IMP) was used to study the dynamics of cerebellar and brainstem metabolic function in patients with Mochado-Joseph disease (MJD), the diagnosis of which was confirmed with genetic analysis. The SPECT data obtained was analyzed semiquantitatively. In patients with MJD, ( 123 I)-IMP accumulation in the cerebellum and brainstem was decreased, and the degree of decrease reflected the clinical severity of MJD. When MJD was mild, the decrease in ( 123 I)-IMP accumulation was much greater in the brainstem than in the cerebellum. However, the decrease in ( 123 I)-IMP accumulation in the cerebellum and brainstem was not correlated with the severity of atrophy or with the number of CAG repeats. ( 123 I)-IMP SPECT was useful for evaluating the decrease in cerebellum and brainstem function in patients with MJD. Results of this study suggest that the functional decrease in MJD may begin in the brainstem. (author)

  19. Quantitative assessment of cerebral blood flow by 123I-IMP SPECT

    International Nuclear Information System (INIS)

    Moriwaki, Hiroshi; Matsumoto, Masayasu; Hashikawa, Kazuo

    1993-01-01

    To establish a noninvasive, quantitative method for measuring regional cerebral blood flow (rCBF) by N-isopropyl-p-[ 123 I]iodoamphetamine ( 123 I-IMP) SPECT, we attempted to employ continuous venous sampling instead of arterial sampling. Forty two patients with cerebrovascular disease were classified into two groups, with (group II: n=35) and without (group I: n=7) hand warming. In group II, either hand was warmed, wrapping in a hot blanket (group IIA) or immersed in a 44degC water bath (group IIB). Immediately after intravenous bolus injection of 222 MBq IMP, arterial and venous blood samples were collected continuously for 5 min from the radial artery and the cubital vein, respectively. By octanol extraction, IMP was divided into the unmetabolized and metabolized fractions. The ratio of 123 I-IMP of venous blood to arterial blood (pass ratio, referred to as %PR) was calculated in the whole blood, unmetabolized, and metabolized fractions. Using these parameters, we assessed the possibility to estimate the amount of unmetabolized IMP fraction of arterial blood, usually used as an input function, from venous samples. In group I, %PR demonstrated a considerable variation between individuals (whole IMP, 47.5±24.6%; unmetabolized IMP, 46.0±24.5%; metabolized IMP, 51.8±27.4%). In group II, especially in group IIB, both increase of %PR value and the decrease in variation (whole, 77.9±5.6%; unmetabolized, 75.7±5.7%; metabolized, 86.7±8.7%) were observed, permitting the further calculation based on the assumption that %PR value was constant in each IMP fraction. The coefficient of variation of the difference between estimated arterial IMP radioactivity from venous samples and actual arterial IMP was 9.0% and 7.5%. The use of venous sampling coupled with a hand warming technique allowed the estimation of the arterial unmetabolized IMP radioactivity from venous samples with a reliability of 90% or more. (author)

  20. Progress of highly charged atomic physics at IMP

    International Nuclear Information System (INIS)

    Ma, X; Zhu, X L; Liu, H P; Li, B; Wei, B R; Sha, S; Cao, S P; Chen, L F; Zhang, S F; Feng, W T; Zhang, D C; Qian, D B

    2007-01-01

    The progress of atomic physics researches at the Institute of Modern Physics (IMP) is reviewed, covering the studies on ion-atom/molecule collisions, ion-cluster interaction, negative ion formation, state-selective electron capture studied by COLTRIMS, as well as the progress of a new experimental area dedicated for atomic researches at moderate energies, and the advances of the cooler storage rings at the Heavy Ion Research Facility in Lanzhou (HIRFL). New opportunities to study collision dynamics from femto-second to atto-second regime are opened based on the present facilities and the on-going projects

  1. Expression of IGF-II mRNA-binding proteins (IMPs) in gonads and testicular cancer

    DEFF Research Database (Denmark)

    Hammer, Niels A; Hansen, Thomas v O; Byskov, Anne Grete

    2005-01-01

    prompted us to examine their possible involvement in testicular neoplasia. IMPs were detected primarily in germ-cell neoplasms, including preinvasive testicular carcinoma in situ, classical and spermatocytic seminoma, and nonseminomas, with particularly high expression in undifferentiated embryonal...... carcinoma. The relative expression of IMP1, IMP2 and IMP3 varied among tumor types and only IMP1 was detected in all carcinoma in situ cells. Thus IMPs, and in particular IMP1, may be useful auxiliary markers of testicular neoplasia....

  2. pIMP-PH114 carrying bla IMP-4 in a Klebsiella pneumoniae strain is closely related to other multidrug-resistant IncA/C2 plasmids.

    Science.gov (United States)

    Ho, Pak-Leung; Lo, Wai-U; Chan, Jane; Cheung, Yuk-Yam; Chow, Kin-Hung; Yam, Wing-Cheong; Lin, Chi-Ho; Que, Tak-Lun

    2014-02-01

    The IncA/C plasmids are broad host-range vehicles which have been associated with wide dissemination of CMY-2 among Enterobacteriaceae of human and animal origins. Acquired metallo-β-lactamases (MBLs) such as the IMP-type enzymes are increasingly reported in multidrug-resistant Gram-negative bacteria worldwide, particularly in Enterobacteriaceae. We described the complete sequence of the first IMP-4-encoding IncA/C2 plasmid, pIMP-PH114 (151,885 bp), from a sequence type 1 Klebsiella pneumoniae strain that was recovered from a patient who was hospitalized in the Philippines. pIMP-PH114 consists of a backbone from the IncA/C2 plasmids, with the insertion of a novel Tn21-like class 1 integron composite structure (containing the cassette array bla IMP-4-qacG-aacA4-catB3, followed by a class C β-lactamase bla DHA-1 and the mercury resistance operon, merRTPCADE) and a sul2-floR encoding region. Phylogenetic analysis of the IncA/C repA sequences showed that pIMP-PH114 formed a subgroup with other IncA/C plasmids involved in the international spread of CMY-2, TEM-24 and NDM-1. Identical bla IMP-4 arrays have been described among different Enterobacteriaceae and Acinetobacter spp. in China, Singapore and Australia but the genetic context is different. The broad host range of IncA/C plasmids may have facilitated dissemination of the bla IMP-4 arrays among different diverse groups of bacteria.

  3. IMp: The customizable LEGO® Pinned Insect Manipulator

    Directory of Open Access Journals (Sweden)

    Steen Dupont

    2015-02-01

    Full Text Available We present a pinned insect manipulator (IMp constructed of LEGO® building bricks with two axes of movement and two axes of rotation. In addition we present three variants of the IMp to emphasise the modular design, which facilitates resizing to meet the full range of pinned insect specimens, is fully customizable, collapsible, affordable and does not require specialist tools or knowledge to assemble.

  4. IMp: The customizable LEGO® Pinned Insect Manipulator

    Science.gov (United States)

    Dupont, Steen; Price, Benjamin; Blagoderov, Vladimir

    2015-01-01

    Abstract We present a pinned insect manipulator (IMp) constructed of LEGO® building bricks with two axes of movement and two axes of rotation. In addition we present three variants of the IMp to emphasise the modular design, which facilitates resizing to meet the full range of pinned insect specimens, is fully customizable, collapsible, affordable and does not require specialist tools or knowledge to assemble. PMID:25685035

  5. Characterization of the Eimeria maxima sporozoite surface protein IMP1.

    Science.gov (United States)

    Jenkins, M C; Fetterer, R; Miska, K; Tuo, W; Kwok, O; Dubey, J P

    2015-07-30

    The purpose of this study was to characterize Eimeria maxima immune-mapped protein 1 (IMP1) that is hypothesized to play a role in eliciting protective immunity against E. maxima infection in chickens. RT-PCR analysis of RNA from unsporulated and sporulating E. maxima oocysts revealed highest transcription levels at 6-12h of sporulation with a considerable downregulation thereafter. Alignment of IMP1 coding sequence from Houghton, Weybridge, and APU-1 strains of E. maxima revealed single nucleotide polymorphisms that in some instances led to amino acid changes in the encoded protein sequence. The E. maxima (APU-1) IMP1 cDNA sequence was cloned and expressed in 2 different polyHis Escherichia coli expression vectors. Regardless of expression vector, recombinant E. maxima IMP1 (rEmaxIMP1) was fairly unstable in non-denaturing buffer, which is consistent with stability analysis of the primary amino acid sequence. Antisera specific for rEmaxIMP1 identified a single 72 kDa protein or a 61 kDa protein by non-reducing or reducing SDS-PAGE/immunoblotting. Immunofluorescence staining with anti-rEmaxIMP1, revealed intense surface staining of E. maxima sporozoites, with negligible staining of merozoite stages. Immuno-histochemical staining of E. maxima-infected chicken intestinal tissue revealed staining of E. maxima developmental stages in the lamnia propia and crypts at both 24 and 48 h post-infection, and negligible staining thereafter. The expression of IMP1 during early stages of in vivo development and its location on the sporozoite surface may explain in part the immunoprotective effect of this protein against E. maxima infection. Published by Elsevier B.V.

  6. IMP3 expression is associated with poor outcome and epigenetic deregulation in intrahepatic cholangiocarcinoma.

    Science.gov (United States)

    Gao, Yuanyuan; Yang, Michelle; Jiang, Zhong; Woda, Bruce A; Mercurio, Arthur M; Qin, Jianjie; Huang, Xinli; Zhang, Feng

    2014-06-01

    IMP3 is a fetal protein not expressed in normal adult tissues. IMP3 is an oncoprotein and a useful biomarker for a variety of malignancies and is associated with reduced overall survival of a number of them. IMP3 expression and its prognostic value for patients with intrahepatic cholangiocarcinoma (ICC) have not been well investigated. The molecular mechanism underlying IMP3 expression in human cancer cells remains to be elucidated. Here we investigated IMP3 expression in ICC and adjacent nonneoplastic liver in 72 unifocal primary ICCs from a single institute by immunohistochemistry, immunoblotting, and real-time polymerase chain reaction. IMP3 was specifically expressed in cancer cells but not in the surrounding normal tissue, and 59 (82%) of 72 ICCs were IMP3 positive by immunohistochemistry. Among 35 cases with lymphovascular invasion, 26 (74%) showed IMP3 positivity in lymph node metastases. IMP3 expression was significantly correlated with tumor size, pathological grade, metastasis, and clinical stage. Kaplan-Meier analysis demonstrated an inverse correlation between IMP3 expression and overall survival rate. Multivariate analysis revealed that IMP3 was the only risk factor associated with survival. To further explore the mechanism of IMP3 expression in cancers, we identified 2 CpG islands at IMP3 proximal promoter. Interestingly, the IMP3 promoter was almost completely demethylated in ICCs in contrast to densely methylated promoter in normal liver tissues. IMP3 expression is a useful biomarker for ICCs and can provide an independent prognostic value for patients with ICC. To our knoweldge, this is the first direct evidence of epigenetic deregulation of IMP3 in human cancer. Copyright © 2014 The Auhtors. Published by Elsevier Inc. All rights reserved.

  7. Operation of the Electronics for the AMS-02RICH Detector Prototype

    Energy Technology Data Exchange (ETDEWEB)

    Aguayo, P.; Aguilar, M.; Berdugo, J.; Casaus, J.; Delgado, C.; Diaz, C.; Fernandez, C.; Garcia-Tabares, L.; Lanciotti, E.; Mana, C.; Marin, J.; Martinez, G.; Palomares, C.; Sanchez, E.; Sevilla, I.; Torrento, A.; Wilmott, C.; Yanez, J.

    2002-07-01

    The operation and behaviour of the RICH prototype electronics developed for the AMS-02 experiment is presented. It includes results and conclusions obtained from experimental tests data with cosmic rays. (Author)

  8. Indoor Free Space Optic: a new prototype, realization and evaluation

    Science.gov (United States)

    Bouchet, Olivier; Besnard, Pascal; Mihaescu, Adrian

    2008-08-01

    The Free Space Optic (FSO) communication is a daily reality used by an increasing number of companies. For indoor environment, optical wireless communication becomes a good alternative with respect to radio proposals. For both technologies, the architecture is similar: emission/reception base station (Gateway or Bridge) are installed to cover zones, which are defined to ensure a quality of service. The customers may be connected to the Wireless Local Area Network (WLAN) with an adapter or module that emits and receives on this network. But due to its specific characteristics, wireless optical technology could present important advantages such as: Transmitted data security, medical immunity, high data rate, etc... Nevertheless, the optical system may have a limit on the network management aspect and link budget. The scope of this paper is to present a proposal at crossroads between optical fibre telecom system and data processing. In this document, we will present a prototype developed in Brittany during a regional collaborative project (Techim@ges). In order to answer to the management aspect and the link budget, this prototype uses an optical multiplexing technique in 1550 nm band: the Wavelength Division Multiple Access (WDMA). Moreover it also proposes a new class 1 high power emission solution. This full duplex system transmits these various wavelengths in free space, by using optical Multiplexer/Demultiplexer and optical modules. Each module has a defined and personal wavelength associated to the terminal identification (addresses MAC or IP). This approach permits a data rate at a minimum of a ten's Mbit/s per customer and potentially hundred Mbps for a line of sight system. The application field for the achieved and proposed prototype is potentially investigated from WLAN to WPAN.

  9. Imp2, the PSTPIP homolog in fission yeast, affects sensitivity to the immunosuppressant FK506 and membrane trafficking in fission yeast

    International Nuclear Information System (INIS)

    Kita, Ayako; Higa, Mari; Doi, Akira; Satoh, Ryosuke; Sugiura, Reiko

    2015-01-01

    Cytokinesis is a highly ordered process that divides one cell into two cells, which is functionally linked to the dynamic remodeling of the plasma membrane coordinately with various events such as membrane trafficking. Calcineurin is a highly conserved serine/threonine protein phosphatase, which regulates multiple biological functions, such as membrane trafficking and cytokinesis. Here, we isolated imp2-c3, a mutant allele of the imp2 + gene, encoding a homolog of the mouse PSTPIP1 (proline-serine-threonine phosphatase interacting protein 1), using a genetic screen for mutations that are synthetically lethal with calcineurin deletion in fission yeast. The imp2-c3 mutants showed a defect in cytokinesis with multi-septated phenotypes, which was further enhanced upon treatment with the calcineurin inhibitor FK506. Notably, electron micrographs revealed that the imp2-c3 mutant cells accumulated aberrant multi-lamella Golgi structures and putative post-Golgi secretory vesicles, and exhibited fragmented vacuoles in addition to thickened septa. Consistently, imp2-c3 mutants showed a reduced secretion of acid phosphatase and defects in vacuole fusion. The imp2-c3 mutant cells exhibited a weakened cell wall, similar to the membrane trafficking mutants identified in the same genetic screen such as ypt3-i5. These findings implicate the PSTPIP1 homolog Imp2 in Golgi/vacuole function, thereby affecting various cellular processes, including cytokinesis and cell integrity. - Highlights: • We isolated imp2-c3, in a synthetic lethal screen with calcineurin in fission yeast. • The imp2 + gene encodes a component of the actin contractile ring similar to Cdc15. • The imp2-c3 mutants showed defects in cytokinesis, which were exacerbated by FK506. • The imp2-c3 mutants were defective in membrane trafficking and cell wall integrity. • Our study revealed a novel role for Imp2 in the Golgi/vacuolar membrane trafficking

  10. Imp2, the PSTPIP homolog in fission yeast, affects sensitivity to the immunosuppressant FK506 and membrane trafficking in fission yeast

    Energy Technology Data Exchange (ETDEWEB)

    Kita, Ayako; Higa, Mari [Laboratory of Molecular Pharmacogenomics, School of Pharmaceutical Sciences, Kinki University, 3-4-1 Kowakae, Higashi-Osaka 577-8502 (Japan); Doi, Akira [Laboratory of Molecular Pharmacogenomics, School of Pharmaceutical Sciences, Kinki University, 3-4-1 Kowakae, Higashi-Osaka 577-8502 (Japan); Japan Society for the Promotion of Science, 1-8 Chiyoda-ku, Tokyo 102-8472 (Japan); Satoh, Ryosuke [Laboratory of Molecular Pharmacogenomics, School of Pharmaceutical Sciences, Kinki University, 3-4-1 Kowakae, Higashi-Osaka 577-8502 (Japan); Sugiura, Reiko, E-mail: sugiurar@phar.kindai.ac.jp [Laboratory of Molecular Pharmacogenomics, School of Pharmaceutical Sciences, Kinki University, 3-4-1 Kowakae, Higashi-Osaka 577-8502 (Japan)

    2015-02-13

    Cytokinesis is a highly ordered process that divides one cell into two cells, which is functionally linked to the dynamic remodeling of the plasma membrane coordinately with various events such as membrane trafficking. Calcineurin is a highly conserved serine/threonine protein phosphatase, which regulates multiple biological functions, such as membrane trafficking and cytokinesis. Here, we isolated imp2-c3, a mutant allele of the imp2{sup +} gene, encoding a homolog of the mouse PSTPIP1 (proline-serine-threonine phosphatase interacting protein 1), using a genetic screen for mutations that are synthetically lethal with calcineurin deletion in fission yeast. The imp2-c3 mutants showed a defect in cytokinesis with multi-septated phenotypes, which was further enhanced upon treatment with the calcineurin inhibitor FK506. Notably, electron micrographs revealed that the imp2-c3 mutant cells accumulated aberrant multi-lamella Golgi structures and putative post-Golgi secretory vesicles, and exhibited fragmented vacuoles in addition to thickened septa. Consistently, imp2-c3 mutants showed a reduced secretion of acid phosphatase and defects in vacuole fusion. The imp2-c3 mutant cells exhibited a weakened cell wall, similar to the membrane trafficking mutants identified in the same genetic screen such as ypt3-i5. These findings implicate the PSTPIP1 homolog Imp2 in Golgi/vacuole function, thereby affecting various cellular processes, including cytokinesis and cell integrity. - Highlights: • We isolated imp2-c3, in a synthetic lethal screen with calcineurin in fission yeast. • The imp2{sup +} gene encodes a component of the actin contractile ring similar to Cdc15. • The imp2-c3 mutants showed defects in cytokinesis, which were exacerbated by FK506. • The imp2-c3 mutants were defective in membrane trafficking and cell wall integrity. • Our study revealed a novel role for Imp2 in the Golgi/vacuolar membrane trafficking.

  11. Inverse Free Electron Laser accelerator

    International Nuclear Information System (INIS)

    Fisher, A.; Gallardo, J.; van Steenbergen, A.; Sandweiss, J.

    1992-09-01

    The study of the INVERSE FREE ELECTRON LASER, as a potential mode of electron acceleration, is being pursued at Brookhaven National Laboratory. Recent studies have focussed on the development of a low energy, high gradient, multi stage linear accelerator. The elementary ingredients for the IFEL interaction are the 50 MeV Linac e - beam and the 10 11 Watt CO 2 laser beam of BNL's Accelerator Test Facility (ATF), Center for Accelerator Physics (CAP) and a wiggler. The latter element is designed as a fast excitation unit making use of alternating stacks of Vanadium Permendur (VaP) ferromagnetic laminations, periodically interspersed with conductive, nonmagnetic laminations, which act as eddy current induced field reflectors. Wiggler parameters and field distribution data will be presented for a prototype wiggler in a constant period and in a ∼ 1.5 %/cm tapered period configuration. The CO 2 laser beam will be transported through the IFEL interaction region by means of a low loss, dielectric coated, rectangular waveguide. Short waveguide test sections have been constructed and have been tested using a low power cw CO 2 laser. Preliminary results of guide attenuation and mode selectivity will be given, together with a discussion of the optical issues for the IFEL accelerator. The IFEL design is supported by the development and use of 1D and 3D simulation programs. The results of simulation computations, including also wiggler errors, for a single module accelerator and for a multi-module accelerator will be presented

  12. Integrated maintenance program (IMP)

    International Nuclear Information System (INIS)

    Zemdegs, R.T.; Chout, Q.B.

    1998-01-01

    Approaches to the maintenance of nuclear power plants have undergone significant change in the past several decades. The traditional breakdown approach has been displaced by preventive (calendar-based) maintenance and more recently, by condition-based maintenance (CBM). This is largely driven by the fact that traditional maintenance programs, derived primarily from equipment vendor recommendations, are generally unsuccessful in controlling maintenance costs or equipment failures. Many advances in the maintenance field have taken place since the maintenance plans for Ontario Hydro's nuclear plants were initially established. Ontario Hydro nuclear plant operating costs can be substantially reduced and Incapability Factor improved with the application of modern maintenance processes and tools. Pickering is designated as the lead station for IMP. Of immediate concern is the fact that Pickering Nuclear Division has been experiencing a significant backlog of Operating Preventive Maintenance Callups. This backlog, over 2000, is unacceptable to both station management and the nuclear regulator, the Atomic Energy Control Board. In addition there are over 500 callups in various stages of revision (in hyperspace) without an adequate control nor reporting system to manage their completion. There is also considerable confusion about the classification of l icensing c allups, e.g. callups which are mandatory as a result of legal requirements. Furthermore the ineffectiveness of the Preventive Maintenance (PM) has been the subject of peer audits and Atomic Energy Control Board (AECB) findings over the past several years. The current preventive maintenance ratio PM2 /(PM+CM3) at Pickering ND is less than 20%, due to the current high load of equipment breakdown. This past summer, an Independent Integrated Performance Assessment (IIPA) review at Ontario Hydro confirmed these concerns. Over the past several years, Ontario Hydro nuclear staff have evaluated several programs to improve

  13. Prototype sector magnets for the GeV electron microtron (GEM)

    International Nuclear Information System (INIS)

    Wehrle, R.B.; Norem, J.H.; Praeg, W.F.; Swanstrom, R.H.; Thompson, K.M.

    1983-01-01

    Three prototypes of the sector magnets for GeV Electon Microtron accelerators have been designed. One has been built and two are being constructed. The first is a full scale, 168 ton prototype for one-half of a 2 GeV Double Sided Microtron (DSM) sector magnet. The successful fabrication and testing of the pole pieces for this prototype has demonstrated that their required close tolerances for flatness and parallelism can be met. The second magnet is an approximate two-thirds scale model of one step at the low energy end of the hexatron sector magnet designed for the 4 GeV Electron Microtron (GEM). The measured fields demonstrate that the field falls off faster than an Enge-short-tail and error fields are at low levels and are controllable. A third prototype magnet exactly duplicates the full scale geometry of the first three full orbits of the GEM sector magnet from entrance to exit points. It will permit high precision measurements and corrections of field errors and verify the 3-D computer program, TOSCA

  14. A full-scale prototype for the tracking chambers of the ALICE muon spectrometer. Part II- Electronics. Preamplifier; Read-out prototype

    Energy Technology Data Exchange (ETDEWEB)

    Courtat, P.; Charlet, D.; Lebon, S.; Martin, J.M.; Sellem, R.; Wanlin, E. [CEA Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France). Service d' Electronique Physique; Douet, R.; Harroch, H.; Bimbot, L.; Jouan, D.; Kharmandarian, L.; Le Bornec, Y.; Mac Cormick, M.; Willis, N. [Paris-11 Univ., 91 - Orsay (France). Institut de Physique Nucleaire

    1999-07-01

    A full scale prototype of one module of the first tracking station has already been constructed. It will be equipped with the new read-out electronics proposed for the final chambers. Before integration of the whole chain, tests have been carried out on the individual components in discrete circuit prototypes. The different parts of the chain are described, together with the tests performed. The final version with integrated circuits in then described. (author)

  15. A full-scale prototype for the tracking chambers of the ALICE muon spectrometer. Part II- Electronics. Preamplifier; Read-out prototype

    International Nuclear Information System (INIS)

    Courtat, P.; Charlet, D.; Lebon, S.; Martin, J.M.; Sellem, R.; Wanlin, E.; Douet, R.; Harroch, H.; Bimbot, L.; Jouan, D.; Kharmandarian, L.; Le Bornec, Y.; Mac Cormick, M.; Willis, N.

    1999-01-01

    A full scale prototype of one module of the first tracking station has already been constructed. It will be equipped with the new read-out electronics proposed for the final chambers. Before integration of the whole chain, tests have been carried out on the individual components in discrete circuit prototypes. The different parts of the chain are described, together with the tests performed. The final version with integrated circuits in then described. (author)

  16. A prototype BPM electronics module for RHIC

    International Nuclear Information System (INIS)

    Ryan, W.A.; Shea, T.J.; Cerniglia, P.; Degen, C.M.

    1993-01-01

    Prototype components of the VXI-based Beam Position Monitor Electronics for the Relativistic Heavy Ion Collider have been constructed and tested for accuracy, resolution and linearity. The detector, designed solely for single-bunch acquisition, consists of a homodyne detector followed by a sample and hold and Analog-to-Digital Converter. In the final modules, an on-board Digital Signal Processor will provide turn by turn data correction, continuously updated closed-orbit averaging, and circular buffer maintenance. A timing processor allows synchronization of modules to enable correlated data collection

  17. Linac technology for free-electron lasers

    International Nuclear Information System (INIS)

    Cooper, R.K.; Morton, P.L.; Wilson, P.B.; Keefe, D.; Faltens, A.

    1983-01-01

    The purpose of this paper is to concentrate on the properties of high-energy electron linear accelerators for use in free-electron lasers operating principally in the Compton regime. To fix our focus somewhat, we shall consider electron energies in the 20- to 200-MeV range and consider requirements for high-power free-electron lasers operating in the 0.5- to 10-μm range. Preliminary remarks are made on high-power free-electron laser amplifiers and oscillators and some desirable characteristics of the linacs that deliver electron beams for these devices. Both the high peak-current requirements of the amplifier and the high pulse-repetition frequency requirements of the oscillator can be met by present-day linac technology, although not necessarily by the same machine. In this papers second and third section, the technology of two rather different types of linear accelerators, the rf linac and the induction linac, is reviewed. In conclusion, applications to the Free Electron Lasers are stated

  18. IMP3 expression in human ovarian cancer is associated with improved survival

    DEFF Research Database (Denmark)

    Noske, Aurelia; Faggad, Areeg; Wirtz, Ralph

    2009-01-01

    The insulin-like growth factor-II mRNA-binding protein IMP3 plays an important role in embryogenesis and recent reports suggest an involvement in tumorigenesis. Although IMP3 expression has been well studied in mouse and human fetal and adult gonads, its role in ovarian cancer is unknown. We...... investigated the expression of IMP3 at protein and mRNA levels in a cohort of primary ovarian carcinomas and in 11 ovarian cancer cell lines. Western blot analysis revealed an expression of IMP3 in all ovarian cancer cell lines and immunohistochemistry demonstrated a positive cytoplasmic staining in 32 of 68...... carcinomas (47%). In contrast, epithelium of borderline tumors, as well as, benign ovarian lesions and normal ovaries exhibited only weak or no IMP3 expression. In univariate Kaplan-Meier analysis, IMP3 protein expression was significantly associated with better overall survival (P=0.048). To confirm...

  19. Lead-Free Electronics: Impact for Space Electronics

    Science.gov (United States)

    Sampson, Michael J.

    2010-01-01

    Pb is used as a constituent in solder alloys used to connect and attach electronic parts to printed wiring boards (PWBs). Similar Pbbearing alloys are electroplated or hot dipped onto the terminations of electronic parts to protect the terminations and make them solderable. Changing to Pb-free solders and termination finishes has introduced significant technical challenges into the supply chain. Tin/lead (Sn/Pb) alloys have been the solders of choice for electronics for more than 50 years. Pb-free solder alloys are available but there is not a plug-in replacement for 60/40 or 63/37 (Sn/Pb) alloys, which have been the industry workhorses.

  20. High frequency free-electron laser results

    International Nuclear Information System (INIS)

    Boyer, K.; Brau, C.A.; Newman, B.E.; Stein, W.E.; Warren, R.W.; Winston, J.G.; Young, L.M.

    1983-01-01

    By looking at the free-electron laser as a particle accelerator working backwards, Morton realized that the techniques used to accelerate particles could be used to improve the performance of free-electron lasers. In particular, he predicted the capture of electrons in ''stable-phase'' regions, or ''buckets'' in the electron phase space, and proposed that by decelerating the buckets, the trapped electrons could be decelerated to extract significant amounts of their energy as optical radiation. In fact, since electrons not trapped in the stable regions are forever excluded from them--at least in the adiabatic approximation--displacement techniques could also be used to accelerate or decelerate electrons in a free-electron laser. This paper explains the principle behind ''phase-displacement'' acceleration and details an experiment carried out with a 20-MeV electron beam to test these predictions. Results obtained with a tapered-wiggler free-electron laser demonstrate the concepts proposed by Morton for enhanced efficiency. They show deceleration of electrons by as much as 7% and extraction of more than 3% of the total electron-beam energy as laser energy when the laser is operated as an amplifier. The experiment is presently being reconfigured to examine its performance as a laser oscillator

  1. Detection of bla-IMP-1 and bla-IMP-2 Genes Among Metallo-β-lactamase-Producing Pseudomonas Aeruginosa Isolated from Burn Patients in Isfahan

    Directory of Open Access Journals (Sweden)

    M. Pourbabaee

    2016-02-01

    Full Text Available Background: Pseudomonas aeruginosa is a nosocomial pathogen which especially causes infections among burn patients. Carbapenems are extensively used for the treatment of infections caused by multidrug-resistant P. aeruginosa isolates. The emergence of carbapenemases producing isolates is an outcome of increased utilization of carbapenems. The aim of this study was to determine the bla-IMP-1 and bla-IMP-2 genes in metallo-β-lactamase (MBL -producing Pseudomonas aeruginosa isolated from burn patients in Isfahan. Material and Methods: A total of 150 P. aeruginosa were isolated from burn patients hospitalized in Imam-Mousakazem hospital in Isfahan. Antimicrobial susceptibility was determined using disk diffusion method according to the Clinical and Laboratory Standards Institute (CLSI guidelines. Double Disk Synergy Test (DDST was carried out for screening of MBL production in imipenem-resistant strains. PCR assays were used for detection of bla-IMP-1 and bla-IMP-2 genes among metallo-β-lactamase-producing Pseudomonas aeruginosa isolates. The purified PCR products were sequenced. Results: Of 150 Pseudomonas aeruginosa isolates, %100 identified as multi-drug resistant strains. The most resistance rates were seen against ciprofloxacin, tobromycin, meropenem and imipenem. All of 144 imipenem-resistant Pseudomonas aeruginosa isolates were MBL producing by DDST test. Twenty-nine (19.3% and 8(5.3% MBL producing Pseudomonas aeruginosa isolates harbored bla-IMP-1 and bla-IMP-2 genes respectively. Conclusions: According to results of this study high level resistance to imipenem and MBl genes carriage was seen among Pseudomonas aeruginosa isolated from burn patient infections in our region.

  2. Medida Interpessoal de Psicopatia (IM-P: estudo preliminar no contexto brasileiro Interpersonal Measure of Psychopathy (IM-P: preliminary study in the Brazilian context

    Directory of Open Access Journals (Sweden)

    Tárcia Rita Davoglio

    2011-01-01

    Full Text Available INTRODUÇÃO: A observação direta do comportamento interpessoal é um recurso importante na descrição e diagnóstico da personalidade psicopática. A Medida Interpessoal de Psicopatia (Interpersonal Measure of Psychopathy, IM-P é um instrumento psicométrico composto por 21 itens, desenvolvido para ser utilizado em associação com outras escalas de avaliação da psicopatia. Foca-se, especificamente, nos comportamentos interpessoais e aspectos não verbais evidentes na interação do entrevistador com indivíduos que apresentam características psicopáticas. OBJETIVO: Descrever resultados preliminares sobre a investigação de aspectos interpessoais da psicopatia mediante a utilização da IM-P, incluindo as etapas de tradução/adaptação e avaliação de confiabilidade interavaliadores da IM-P, em uma amostra de adolescentes brasileiros. MÉTODO: Trata-se de estudo transversal, descritivo e correlacional realizado com 20 adolescentes masculinos cumprindo medida socioeducativa com privação de liberdade na Região Metropolitana de Porto Alegre (RS. Após os procedimentos de tradução da escala, treinamento dos pesquisadores e teste piloto por meio de uma entrevista semiestruturada, a IM-P foi pontuada por três juízes independentes. RESULTADOS: Os resultados estatísticos, obtidos através do coeficiente de concordância de Kendall, revelaram grau de concordância interavaliadores elevado e satisfatório para os escores totais da IM-P (W = 0,84; p INTRODUCTION: The direct observation of interpersonal behaviors is an important resource in the description and diagnosis of the psychopathic personality. The Interpersonal Measure of Psychopathy (IM-P is a psychometric instrument comprised of 21 items, designed to be applied in association with other instruments that also evaluate psychopaths. It focuses specifically on interpersonal and non-verbal behaviors that become evident during the interaction between the interviewer and individuals

  3. IMp: The customizable LEGO(®) Pinned Insect Manipulator.

    Science.gov (United States)

    Dupont, Steen; Price, Benjamin; Blagoderov, Vladimir

    2015-01-01

    We present a pinned insect manipulator (IMp) constructed of LEGO® building bricks with two axes of movement and two axes of rotation. In addition we present three variants of the IMp to emphasise the modular design, which facilitates resizing to meet the full range of pinned insect specimens, is fully customizable, collapsible, affordable and does not require specialist tools or knowledge to assemble.

  4. Prototype system for proton beam range measurement based on gamma electron vertex imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Han Rim [Neutron Utilization Technology Division, Korea Atomic Energy Research Institute, 111, Daedeok-daero 989beon-gil, Yuseong-gu, Daejeon 34057 (Korea, Republic of); Kim, Sung Hun; Park, Jong Hoon [Department of Nuclear Engineering, Hanyang University, Seongdong-gu, Seoul 04763 (Korea, Republic of); Jung, Won Gyun [Heavy-ion Clinical Research Division, Korean Institute of Radiological & Medical Sciences, Seoul 01812 (Korea, Republic of); Lim, Hansang [Department of Electronics Convergence Engineering, Kwangwoon University, Seoul 01897 (Korea, Republic of); Kim, Chan Hyeong, E-mail: chkim@hanyang.ac.kr [Department of Nuclear Engineering, Hanyang University, Seongdong-gu, Seoul 04763 (Korea, Republic of)

    2017-06-11

    In proton therapy, for both therapeutic effectiveness and patient safety, it is very important to accurately measure the proton dose distribution, especially the range of the proton beam. For this purpose, recently we proposed a new imaging method named gamma electron vertex imaging (GEVI), in which the prompt gammas emitting from the nuclear reactions of the proton beam in the patient are converted to electrons, and then the converted electrons are tracked to determine the vertices of the prompt gammas, thereby producing a 2D image of the vertices. In the present study, we developed a prototype GEVI system, including dedicated signal processing and data acquisition systems, which consists of a beryllium plate (= electron converter) to convert the prompt gammas to electrons, two double-sided silicon strip detectors (= hodoscopes) to determine the trajectories of those converted electrons, and a plastic scintillation detector (= calorimeter) to measure their kinetic energies. The system uses triple coincidence logic and multiple energy windows to select only the events from prompt gammas. The detectors of the prototype GEVI system were evaluated for electronic noise level, energy resolution, and time resolution. Finally, the imaging capability of the GEVI system was tested by imaging a {sup 90}Sr beta source, a {sup 60}Co gamma source, and a 45-MeV proton beam in a PMMA phantom. The overall results of the present study generally show that the prototype GEVI system can image the vertices of the prompt gammas produced by the proton nuclear interactions.

  5. Photonic Free-Electron Lasers

    NARCIS (Netherlands)

    van der Slot, Petrus J.M.; Denis, T.; Lee, J.H.H.; van Dijk, M.W.; Boller, Klaus J.

    2012-01-01

    A photonic free-electron laser (pFEL) produces coherent Cerenkov radiation from a set of parallel electron beams streaming through a photonic crystal. The function of the crystal is to slow down the phase velocity of a copropagating electromagnetic wave, such that also mildly relativistic electrons

  6. Effects of cigarette smoking on I-123 IMP clearance from the lung

    International Nuclear Information System (INIS)

    Katoh, Kunihiko; Takahashi, Tsuneo

    1990-01-01

    N-isopropyl-p-I-123-iodoamphetamine (I-123 IMP), originally developed as a brain scanning agent, is also taken up by the lung. To evaluate the cigarette smoking on the uptake of IMP by the lung, we studied I-123 IMP clearance from the lung on 14 volunteers; 5 non-smokers and 9 smokers. After the injection of 111 MBq (3mCi) of I-123 IMP into the medial cubital vein, the time-activity curve for 60 minutes and the regional activity using 1 frame per minute and a 64 x 64 matrix was obtained. I-123 IMP clearance curve was described as follows: C(t)=A 1 e -k1t +A 2 e -k2t (A 1 , A 2 : intercepts, and k 1 , k 2 : slopes of the exponential components). I-123 IMP clearance was delayed in smokers, and k 2 was smaller in smokers. Also a significant correlations between k 1 , k 2 , and the number of cigarettes smoked per day were found. In conclusion, this study suggests that the delayed clearance and retention of I-123 IMP in the lung indicate the lung metabolic disorders due to cigarette smoking. (author)

  7. NASAwide electronic publishing system-prototype STI electronic document distribution: Stage-4 evaluation report. Part 2; Appendices

    Science.gov (United States)

    Tuey, Richard C.; Collins, Mary; Caswell, Pamela; Haynes, Bob; Nelson, Michael L.; Holm, Jeanne; Buquo, Lynn; Tingle, Annette; Cooper, Bill; Stiltner, Roy

    1996-01-01

    This evaluation report contains an introduction, seven chapters, and five appendices. The Introduction describes the purpose, conceptual framework, functional description, and technical report server of the Scientific and Technical Information (STI) Electronic Document Distribution (EDD) project. Chapter 1 documents the results of the prototype STI EDD in actual operation. Chapter 2 documents each NASA center's post processing publication processes. Chapter 3 documents each center's STI software, hardware. and communications configurations. Chapter 7 documents STI EDD policy, practices, and procedures. The appendices consist of (A) the STI EDD Project Plan, (B) Team members, (C) Phasing Schedules, (D) Accessing On-line Reports, and (E) Creating an HTML File and Setting Up an xTRS. In summary, Stage 4 of the NASAwide Electronic Publishing System is the final phase of its implementation through the prototyping and gradual integration of each NASA center's electronic printing systems, desk top publishing systems, and technical report servers, to be able to provide to NASA's engineers, researchers, scientists, and external users, the widest practicable and appropriate dissemination of information concerning its activities and the result thereof to their work stations.

  8. Molecular composition of IMP1 ribonucleoprotein granules

    DEFF Research Database (Denmark)

    Jønson, Lars; Vikesaa, Jonas; Krogh, Anders

    2007-01-01

    Localized mRNAs are transported to sites of local protein synthesis in large ribonucleoprotein (RNP) granules, but their molecular composition is incompletely understood. Insulin-like growth factor II mRNA-binding protein (IMP) zip code-binding proteins participate in mRNA localization, and in mo......Localized mRNAs are transported to sites of local protein synthesis in large ribonucleoprotein (RNP) granules, but their molecular composition is incompletely understood. Insulin-like growth factor II mRNA-binding protein (IMP) zip code-binding proteins participate in mRNA localization...

  9. Wind and IMP 8 Solar Wind, Magnetosheath and Shock Data

    Science.gov (United States)

    2004-01-01

    The purpose of this project was to provide the community access to magnetosheath data near Earth. We provided 27 years of IMP 8 magnetosheath proton velocities, densities, and temperatures with our best (usually 1-min.) time resolution. IMP 8 crosses the magnetosheath twice each 125 day orbit, and we provided magnetosheath data for the roughly 27 years of data for which magnetometer data are also available (which are needed to reliably pick boundaries). We provided this 27 years of IMP 8 magnetosheath data to the NSSDC; this data is now integrated with the IMP 8 solar wind data with flags indicating whether each data point is in the solar wind, magnetosheath, or at the boundary between the two regions. The plasma speed, density, and temperature are provided for each magnetosheath point. These data are also available on the MIT web site ftp://space .mit.edu/pub/plasma/imp/www/imp.html. We provide ASCII time-ordered rows of data giving the observation time, the spacecraft position in GSE, the velocity is GSE, the density and temperature for protons. We also have analyzed and archived on our web site the Wind magnetosheath plasma parameters. These consist of ascii files of the proton and alpha densities, speeds, and thermal speeds. These data are available at ftp://space.mit.edu/pub/plasma/wind/sheath These are the two products promised in the work statement and they have been completed in full.

  10. Laser Assisted Free-Free Transition in Electron - Atom Collision

    Science.gov (United States)

    Sinha, C.; Bhatia, A. K.

    2011-01-01

    Free-free transition is studied for electron-Hydrogen atom system in ground state at very low incident energies in presence of an external homogeneous, monochromatic and linearly polarized laser field. The incident electron is considered to be dressed by the laser in a non perturbative manner by choosing the Volkov solutions in both the channels. The space part of the scattering wave function for the electron is solved numerically by taking into account the effect of electron exchange, short range as well as of the long range interactions. Laser assisted differential as well as elastic total cross sections are calculated for single photon absorption/emission in the soft photon limit, the laser intensity being much less than the atomic field intensity. A strong suppression is noted in the laser assisted cross sections as compared to the field free situations. Significant difference is noted in the singlet and the triplet cross sections.

  11. Electron Inelastic-Mean-Free-Path Database

    Science.gov (United States)

    SRD 71 NIST Electron Inelastic-Mean-Free-Path Database (PC database, no charge)   This database provides values of electron inelastic mean free paths (IMFPs) for use in quantitative surface analyses by AES and XPS.

  12. Study of 123I-IMP SPECT on diabetic patients

    International Nuclear Information System (INIS)

    Kinoshita, Ikuo; Takeo, Goh; Iwanaga, Keisuke; Uotani, Shigeo; Nakamura, Minoru; Sohda, Masanori; Ohe, Haruto; Toshimitsu, Takashi; Ohe, Nobuharu

    1991-01-01

    The involvement of peripheral nerves and nerve roots often leads to neurological manifestations which have frequently been described in association with diabetes mellitus. Whether there is any specific involvement of the central nervous system in this process has yet to be determined. Recently, many reports have suggested that significant neurophysiologic abnormalities in the central nervous system can sometimes be found in diabetic patients. In order to accurately examine the existence of central nervous system involvement in patients with diabetes mellitus, comparisons of 123 I-IMP (IMP) washout rates were made between normal adults (n=19, average age 43.3 years) and diabetic patients (n=23, average age 43.3 years), and these results were graphically demonstrated by color images. Early images were obtained 30 minutes after intravenous injection, while delayed images were made 4 hours after injection. The IMP washout rate was obtained by subtracting the values of the delayed image with the early image. The standard deviation (SD) of the IMP washout rate for each patient was compared to the averaged SD obtained from healthy adults. After calculating the deviation from SD levels of healthy adults, we made an image of the patient's IMP washout rates. These images were divided into seven degrees (I, II: normal, III, IV: borderline, V∼VII: abnormal) and the ratio of each degree was expressed by a histogram in each cerebral hemisphere as the washout rate index. In 23 diabetic subjects, seven patients were found to be borderline while sixteen patients were abnormal. These impairments were not related either to the presence of diabetic triopathy or the duration of disease. By utilising such a noninvasive method, we were able to accurately evaluate the extent of diabetic central neuropathy. Therefore this subtraction method, which uses the specificity of IMP SPECT, is thus considered to be highly useful for broad clinical application. (author)

  13. Free-electron lasers considered for CEBAF

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    Spinoff development of industrial free-electron lasers is in prospect for an industry-universitylaboratory consortium centred at the Continuous Electron Beam Accelerator Facility in Newport News, Virginia, site of the CEBAF 4 GeV superconducting radiofrequency (SRF) accelerator, now being commissioned (see page 42). Together with several US corporations and universities, the Laboratory is now also addressing the potential of smaller SRF electron accelerators for ''driving'' free-electron lasers (FELs)

  14. The first 3':5'-cyclic nucleotide-amino acid complex: L-His-cIMP.

    Science.gov (United States)

    Slepokura, Katarzyna

    2012-08-01

    In the crystal structure of the L-His-cIMP complex, i.e. L-histidinium inosine 3':5'-cyclic phosphate [systematic name: 5-(2-amino-2-carboxyethyl)-1H-imidazol-3-ium 7-hydroxy-2-oxo-6-(6-oxo-6,9-dihydro-1H-purin-9-yl)-4a,6,7,7a-tetrahydro-4H-1,3,5,2λ(5)-furo[3,2-d][1,3,2λ(5)]dioxaphosphinin-2-olate], C(6)H(10)N(3)O(2)(+)·C(10)H(10)N(4)O(7)P(-), the Hoogsteen edge of the hypoxanthine (Hyp) base of cIMP and the Hyp face are engaged in specific amino acid-nucleotide (His···cIMP) recognition, i.e. by abutting edge-to-edge and by π-π stacking, respectively. The Watson-Crick edge of Hyp and the cIMP phosphate group play a role in nonspecific His···cIMP contacts. The interactions between the cIMP anions (anti/C3'-endo/trans-gauche/chair conformers) are realized mainly between riboses and phosphate groups. The results for this L-His-cIMP complex, compared with those for the previously reported solvated L-His-IMP crystal structure, indicate a different nature of amino acid-nucleotide recognition and interactions upon the 3':5'-cyclization of the nucleotide phosphate group.

  15. Status and prospect of super-heavy nuclei research at IMP

    International Nuclear Information System (INIS)

    Xu Hushan; Sun Zhiyu; Zhan Wenlong; Zhou Xiaohong; Huang Wenxue; Zhang Hongbin; Gan Zaiguo; Li Junqing; Ma Xinwen; Qin Zhi; Xiao Guoqing; Guo Zhongyan; Li Zhihui; Zhang Yuhu; Jin Genming; Huang Tianheng; Hu Zhengguo; Zhang Xueheng; Zheng Chuan; Chinese Academy of Sciences, Beijing

    2006-01-01

    The history and the international status of the super-heavy nuclei synthesis are briefly described. The related research work carried out at the Institute of Modern Physics (IMP) has been reviewed. The prospect of the super-heavy nuclei research at IMP has been introduced. (authors)

  16. N-isopropyl I-123 p-iodoamphetamine (IMP) brain SPECT in dementia

    International Nuclear Information System (INIS)

    Momose, Toshimitsu; Kosaka, Noboru; Nishikawa, Junichi; Yoshikawa, Kohki; Ohtake, Tohru; Watanabe, Toshiaki; Iwata, Makoto; Shimizu, Teruo; Iio, Masahiro

    1988-01-01

    Six patients of Alzheimer's disease (AD), two patients of Pick disease (PD) and two patients of Creutzfeldt-Jakob disease (CJD) were studied with N-Isopropyl I-123 p-Iodoamphetamine (IMP) with SPECT. The pattern of IMP uptake in these demented groups were compared with that in five agematched normal controls and correlated with MRI and XCT. In all AD cases, SPECT revealed focal reduction of IMP uptake in frontal (6/6), parietal (6/6) and temporal (6/6) cortex, although MRI and XCT were normal. In both PD case, SPECT showed focal reduction of IMP uptake in frontal (1/2) and temporal (2/2) cortex with moderate labor atrophy on MRI and XCT. In both CJD case, SPECT showed diffuse reduction of IMP uptake in cerebral cortex in spite of no abnormality on MRI and XCT. These findings suggest that SPECT can detect earlier diseased process of AD and CJD than MRI or XCT and that SPECT may be helpful for the differential diagnosis of non-vascular dementia. (author)

  17. N-isopropyl I-123 p-iodoamphetamine (IMP) brain SPECT in dementia

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Toshimitsu; Kosaka, Noboru; Nishikawa, Junichi; Yoshikawa, Kohki; Ohtake, Tohru; Watanabe, Toshiaki; Iwata, Makoto; Shimizu, Teruo; Iio, Masahiro

    1988-12-01

    Six patients of Alzheimer's disease (AD), two patients of Pick disease (PD) and two patients of Creutzfeldt-Jakob disease (CJD) were studied with N-Isopropyl I-123 p-Iodoamphetamine (IMP) with SPECT. The pattern of IMP uptake in these demented groups were compared with that in five agematched normal controls and correlated with MRI and XCT. In all AD cases, SPECT revealed focal reduction of IMP uptake in frontal (6/6), parietal (6/6) and temporal (6/6) cortex, although MRI and XCT were normal. In both PD case, SPECT showed focal reduction of IMP uptake in frontal (1/2) and temporal (2/2) cortex with moderate labor atrophy on MRI and XCT. In both CJD case, SPECT showed diffuse reduction of IMP uptake in cerebral cortex in spite of no abnormality on MRI and XCT. These findings suggest that SPECT can detect earlier diseased process of AD and CJD than MRI or XCT and that SPECT may be helpful for the differential diagnosis of non-vascular dementia.

  18. Clinical evaluation of 123I-IMP SPECT in patients with various neurological diseases

    International Nuclear Information System (INIS)

    Yoneda, Naoto

    1993-01-01

    Single photon emission computed tomography with N-isopropyl-p-[ 123 I] iodoamphetamine ( 123 I-IMP SPECT) was performed in 57 patients with various neurological disease, and compared with the findings of brain CT, MRI, and EEG. The author also evaluated the relationship between the findings on 123 I-IMP SPECT and the condition of the control of the attack after treatment with antiepileptic drugs in idiopathic epileptic patients. Abnormality of accumulation of 123 I-IMP SPECT was observed in 62.3% of all cases. Focal abnormality was detected in 28.3% of all cases by brain CT and 54.1% by MRI. The detectability of focal abnormality in brain CT and MRI was found to be lower than that of 123 I-TMP SPECT. There was very little significance in detectability between 123 I-IMP SPECT and EEG. But it infers that 123 I-IMP SPECT can detect the subictal state in epileptic patients. One comparative study of the relationship between the findings on 123 I-IMP SPECT and the condition of the control of the attack by antiepileptic drugs in patients with idiopathic epilepsy, abnormality of 123 I-IMP SPECT findings was found to be higher in patients who were not controlled sufficiently than in patients who were controlled sufficiently, and a significant difference is found by X 2 test. 123 I-IMP SPECT is useful for the evaluation of treatment in patients with epilepsy. (author)

  19. Free-free and fixed base modal survey tests of the Space Station Common Module Prototype

    Science.gov (United States)

    Driskill, T. C.; Anderson, J. B.; Coleman, A. D.

    1992-01-01

    This paper describes the testing aspects and the problems encountered during the free-free and fixed base modal surveys completed on the original Space Station Common Module Prototype (CMP). The CMP is a 40-ft long by 14.5-ft diameter 'waffle-grid' cylinder built by the Boeing Company and housed at the Marshall Space Flight Center (MSFC) near Huntsville, AL. The CMP modal survey tests were conducted at MSFC by the Dynamics Test Branch. The free-free modal survey tests (June '90 to Sept. '90) included interface verification tests (IFVT), often referred to as impedance measurements, mass-additive testing and linearity studies. The fixed base modal survey tests (Feb. '91 to April '91), including linearity studies, were conducted in a fixture designed to constrain the CMP in 7 total degrees-of-freedom at five trunnion interfaces (two primary, two secondary, and the keel). The fixture also incorporated an airbag off-load system designed to alleviate the non-linear effects of friction in the primary and secondary trunnion interfaces. Numerous test configurations were performed with the objective of providing a modal data base for evaluating the various testing methodologies to verify dynamic finite element models used for input to coupled load analysis.

  20. Hypoxic Vasospasm Mediated by cIMP: When Soluble Guanylyl Cyclase Turns Bad.

    Science.gov (United States)

    Gao, Yuansheng; Chen, Zhengju; Leung, Susan W S; Vanhoutte, Paul M

    2015-06-01

    In a number of isolated blood vessel types, hypoxia causes an acute contraction that is dependent on the presence of nitric oxide and activation of soluble guanylyl cyclase. It is more pronounced when the preparations are constricted and is therefore termed hypoxic augmentation of vasoconstriction. This hypoxic response is accompanied by increases in the intracellular level of inosine 5'-triphosphate and in the synthesis of inosine 3',5'-cyclic monophosphate (cIMP) by soluble guanylyl cyclase. The administration of exogenous cIMP or inosine 5'-triphosphate causes augmented vasoconstriction to hypoxia. Furthermore, the vasoconstriction evoked by hypoxia and cIMP is associated with increased activity of Rho kinase (ROCK), indicating that cIMP may mediate the hypoxic effect by sensitizing the myofilaments to Ca through ROCK. Hypoxia is implicated in exaggerated vasoconstriction in the pathogenesis of coronary artery disease, myocardial infarction, hypertension, and stroke. The newly found role of cIMP may help to identify unique therapeutic targets for certain cardiovascular disorders.

  1. Recent nuclear physics research at IMP

    International Nuclear Information System (INIS)

    Jin Genming

    1998-01-01

    The recent progresses in the nuclear physics research in IMP (Institute of Modern Physics) are reviewed including the synthesis and studies of nuclei far from stability and properties of hot nuclei. Heavy Ion Research Facility Lanzhou (HIRFL) is of cyclotron family delivering intermediate energy heavy ions. During the recent years, progresses have been made in the studies of heavy ion physics as well as in the development of the HIRFL. This paper will begin with the recent upgrading of HIRFL with an emphasis on the development of Radioactive Ion Beam Line Lanzhou (RIBLL), and then be focused on the physics research in IMP including intermediate energy heavy ion collisions and hot nuclei, synthesis and studies of nuclei far from stability. (J.P.N)

  2. Clinical significance of I-123 IMP brain SPECT in children with brain diseases

    International Nuclear Information System (INIS)

    Takishima, Teruo; Machida, Kikuo; Honda, Norinari; Mamiya, Toshio; Takahashi, Taku; Kamano, Tsuyoshi; Hasegawa, Noriko

    1990-01-01

    Single photon emission computed tomography (SPECT) of the brain using N-isopropyl p-I-123-iodoamphetamine (I-123 IMP) was performed in 43 children with suspected brain diseases. Forty-three children (25 males and 18 females), with an age range of 24 days-15 years (mean: 6.6 years), were included in the study. Six patients were subsequently diagnosed as normal. Early SPECT of the brain was performed 30 minutes after intravenous administration of 74-111 MBq (2-3 mCi) I-123 IMP using a rotating gamma camera equipped with a 30-degree slant hole and medium energy collimator. Transverse images were reconstructed by Shepp-Logan filtered back projection method with attenuation correction after spatial filtering using an 8th order Butterworth-Wiener filter. Findings of I-123 IMP SPECT were compared with those of X-ray computed tomography (CT) and electroencephalography (EEG). The results showed that in I-123 IMP SPECT, abnormality was found in 30 out of 37 children with brain diseases. The incidence of abnormal findings in the 37 patients was 81% in I-123 IMP SPECT, 61% in X-ray CT, and 78% in EEG; in both cryptogenic and secondary epilepsy, the incidence of abnormality was higher in I-123 IMP SPECT than in X-ray CT. (70% and 94% vs 50% and 81% respectively), and epileptic foci detected by EEG did not correspond with defects found using I-123 IMP SPECT in 27% of the patients; and in asphyxiated infants, a high incidence of abnormality was observed on both I-123 IMP SPECT (86%) and X-ray CT (86%). In conclusion, I-123 IMP SPECT is a clinically useful examination in children with brain disease. (author)

  3. Clear cell carcinomas of the ovary: a mono-institutional study of 73 cases in China with an analysis of the prognostic significance of clinicopathological parameters and IMP3 expression.

    Science.gov (United States)

    Bi, Rui; Shen, Xuxia; Zhang, Weiwei; Cheng, Yufan; Feng, Zheng; Cai, Xu; Yang, Wentao

    2016-02-02

    Ovarian clear cell carcinoma (CCC) is an uncommon subtype of ovarian epithelial tumor. The prognostic significance of its clinicopathological parameters is discordant, with the exception of stage as the adverse prognostic factor. The present study aimed to evaluate the prognostic significance of its clinicopathological characteristics and the expression of IMP3 (Insulin-like growth factor-II mRNA-binding protein 3, IMP3 or IGF2BP3) in Chinese patients with primary pure CCC. We collected clinicopathological data from 73 cases with a minimum of 5 years of follow-up and evaluated the expression of IMP3 by immunohistochemistry. In total, 49.3 % of the patients were in stage I. Advanced stages were closely related to poor prognosis of disease-free survival (DFS) and overall survival (OS) (P 73 cases); Thus, positive expression of IMP3 is an adverse prognostic marker in terms of OS (P = 0.012), even in stage I patients (P = 0.038). The present study demonstrates that IMP3 expression is a prognostic marker, with the exception of stage. IMP3 represents a biomarker of unfavorable prognosis even in stage I patients.

  4. The Two-Beam Free Electron Laser Oscillator

    CERN Document Server

    Thompson, Neil R

    2004-01-01

    A one-dimensional model of a free-electron laser operating simultaneously with two electron beams of different energies [1] is extended to an oscillator configuration. The electron beam energies are chosen so that an harmonic of the lower energy beam is at the fundamental radiation wavelength of the higher energy beam. Potential benefits over a single-beam free-electron laser oscillator are discussed.

  5. Analysis of I-125 IMP and its metabolites using a high performance liquid chromatography

    International Nuclear Information System (INIS)

    Satoh, Motohiro; Ishikawa, Nobuyoshi; Takeda, Tohoru; Jin, Wu; Kuramoto, Kenmei; Itai, Yuji; Yoshizawa, Takashi; Nakajima, Kotaro.

    1991-01-01

    The biodistribution of N-isopropyl-p-[I-123]iodoamphetamine (IMP) and its metabolites was examined in rabbits and Mongolian gerbils. Arterial sampling was performed at one, 5, 15, and 30 min, and one, 3, and 6 hr after bolus iv injection of IMP for the hemodynamic investigation. Similarly, the cerebral hemisphere, lung, liver, and blood samples were collected at 15 min and 3 hr for analyzing IMP metabolites. Activity count in blood was gradually increased from 15 min to 3 hr after iv injection, and thereafter decreased. Relative fraction of IMP in plasma was gradually increased to a plateau value of 80% at one hr. Octanol extraction ratio was decreased to 24.3% at 3 hr, although it was 100% immediately after iv injection. Early (15 min) and delayed (3 hr) analysis using high performance liquid chromatography (HPLC) revealed p-iodoamphetamine (PIA) and p-iodobenzoic acid (PIB) as major metabolites of IMP. Although IMP accounted for the majority on both early and delayed HPLC, the quantity of PIA in the normal hemisphere and lung was significantly increased on delayed HPLC, compared to early HPLC. For the liver, the quantities of both PIA and PIB were larger than IMP on both early and delayed HPLC. The proportion of metabolites also became greater in whole blood than IMP on delayed HPLC. Early HPLC reveald no significant difference in composition of IMP, PIA, and PIB between the normal and ischemic hemispheres. Delayed HPLC revealed a greater proportion of PIA in the ischemic than the normal hemisphere, but this was not statistically significant. (N.K.)

  6. I-123 IMP SPECT in Parkinson's disease

    International Nuclear Information System (INIS)

    Kawabata, Keita; Tachibana, Kyudai; Sugita, Minoru

    1990-01-01

    To examine semiquantitatively regional cerebral blood flow, SPECT with N-isopropyl-p-[I-123]iodoamphetamine (I-123 IMP) was undertaken in 17 patients with Parkinson's disease. Seven patients with Alzheimer's disease and 9 senile control subjects were also imaged for comparison. Both the Parkinson's disease group and the Alzheimer's disease group had a decreased uptake of I-123 IMP in the frontal lobe, in comparison with the control group. A remarkably decreased uptake was seen in the lateral and parietal lobes in the group of Parkinson's disease associated with dementia, as well as in the Alzheimer's disease group. A significantly decreased uptake was observed in the frontal lobe, lateral lobe, thalamus, and basal ganglia in the Parkinson's disease group, irrespective of the presence or absence of dementia. For Parkinson's disease associated with dementia, there was much more significant decrease in I-123 IMP uptake. The pattern of regional cerebral blood flow in the Alzheimer's disease group was analogous to that in the Parkinson's disease group associated with dementia. This supports the hypothesis that Alzheimer's disease may be somewhat involved in the occurrence of dementia for Parkinson's disease. (N.K.)

  7. Free-electron laser results

    International Nuclear Information System (INIS)

    Stein, W.E.; Brau, C.A.; Newnam, B.E.; Warren, R.W.; Winston, J.; Young, L.M.

    1981-01-01

    The Los Alamos free-electron laser (FEL) amplifier experiment was designed to demonstrate high efficiency for transfer of energy from an electron beam to a light beam in the magnetic field of a tapered wiggler. Initial results indicate an energy transfer consistent with theory. Distinct groups of decelerated electrons as well as accelerated electrons are clearly present in the energy spectrum of electrons emerging from the wiggler when the laser light is present. The observed energy decrease for the electrons captured in the decelerating bucket is approx. 6% and the average decrease of the entire energy distribution is approx. 2% for the conditions of these initial measurements

  8. Study of sup 123 I-IMP SPECT on diabetic patients

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, Ikuo; Takeo, Goh; Iwanaga, Keisuke; Uotani, Shigeo; Nakamura, Minoru; Sohda, Masanori; Ohe, Haruto; Toshimitsu, Takashi; Ohe, Nobuharu (Yahata City Hospital, Kitakyushu, Fukuoka (Japan))

    1991-07-01

    The involvement of peripheral nerves and nerve roots often leads to neurological manifestations which have frequently been described in association with diabetes mellitus. Whether there is any specific involvement of the central nervous system in this process has yet to be determined. Recently, many reports have suggested that significant neurophysiologic abnormalities in the central nervous system can sometimes be found in diabetic patients. In order to accurately examine the existence of central nervous system involvement in patients with diabetes mellitus, comparisons of {sup 123}I-IMP (IMP) washout rates were made between normal adults (n=19, average age 43.3 years) and diabetic patients (n=23, average age 43.3 years), and these results were graphically demonstrated by color images. Early images were obtained 30 minutes after intravenous injection, while delayed images were made 4 hours after injection. The IMP washout rate was obtained by subtracting the values of the delayed image with the early image. The standard deviation (SD) of the IMP washout rate for each patient was compared to the averaged SD obtained from healthy adults. After calculating the deviation from SD levels of healthy adults, we made an image of the patient's IMP washout rates. These images were divided into seven degrees (I, II: normal, III, IV: borderline, V{approx}VII: abnormal) and the ratio of each degree was expressed by a histogram in each cerebral hemisphere as the washout rate index. In 23 diabetic subjects, seven patients were found to be borderline while sixteen patients were abnormal. These impairments were not related either to the presence of diabetic triopathy or the duration of disease. By utilising such a noninvasive method, we were able to accurately evaluate the extent of diabetic central neuropathy. Therefore this subtraction method, which uses the specificity of IMP SPECT, is thus considered to be highly useful for broad clinical application. (author).

  9. MRPC prototypes for NeuLAND tested using the single electron mode of ELBE/Dresden

    Energy Technology Data Exchange (ETDEWEB)

    Yakorev, Dmitry; Bemmerer, Daniel; Elekes, Zoltan; Kempe, Mathias; Stach, Daniel; Wagner, Andreas [Forschungszentrum Dresden-Rossendorf (FZD), Dresden (Germany); Aumann, Tom; Boretzky, Konstanze; Caesar, Christoph; Ciobanu, Mircea; Hehner, Joerg; Heil, Michael; Nusair, Omar; Reifarth, Rene; Simon, Haik [GSI, Darmstadt (Germany); Elvers, Michael; Maroussov, Vassili; Zilges, Andreas [Universitaet Koeln (Germany); Zuber, Kai [TU Dresden (Germany)

    2010-07-01

    The NeuLAND detector at the R{sup 3}B experiment at the future FAIR facility in Darmstadt aims to detect fast neutrons (0.2-1.0 GeV) with high time and spatial resolutions ({sigma}{sub t}<100 ps, {sigma}{sub x,y,z}<1 cm). Prototypes for the NeuLAND detector have been built at FZD and GSI and then studied using the 32 MeV pulsed electron beam at the superconducting electron accelerator ELBE in Dresden, Germany. Owing to the new, single-electron per bunch mode of operation, a rapid validation of the design criteria ({>=}90% efficiency for minimum ionizing particles, {sigma} {<=} 100 ps time resolution) was possible. Tested properties of the prototypes include glass thickness, spacing of the central anode, and a comparison of single-ended and differential readout. Tested frontend electronics schemes include FOPI (single-ended), PADI-based (both single-ended and differential mode tested), and ALICE (differential).

  10. IMP3 RNP Safe Houses Prevent miRNA-Directed HMGA2 mRNA Decay in Cancer and Development

    Directory of Open Access Journals (Sweden)

    Lars Jønson

    2014-04-01

    Full Text Available The IMP3 RNA-binding protein is associated with metastasis and poor outcome in human cancer. Using solid cancer transcriptome data, we found that IMP3 correlates with HMGA2 mRNA expression. Cytoplasmic IMP3 granules contain HMGA2, and IMP3 dose-dependently increases HMGA2 mRNA. HMGA2 is regulated by let-7, and let-7 antagomiRs make HMGA2 refractory to IMP3. Removal of let-7 target sites eliminates IMP3-dependent stabilization, and IMP3-containing bodies are depleted of Ago1-4 and miRNAs. The relationship between Hmga2 mRNA and IMPs also exists in the developing limb bud, where IMP1-deficient embryos show dose-dependent Hmga2 mRNA downregulation. Finally, IMP3 ribonucleoproteins (RNPs contain other let-7 target mRNAs, including LIN28B, and a global gene set enrichment analysis demonstrates that miRNA-regulated transcripts in general are upregulated following IMP3 induction. We conclude that IMP3 RNPs may function as cytoplasmic safe houses and prevent miRNA-directed mRNA decay of oncogenes during tumor progression.

  11. A ferroelectric electron gun in a free-electron maser experiment

    International Nuclear Information System (INIS)

    Einat, M.; Jerby, E.; Rosenman, G.

    2002-01-01

    An electron-gun based on a ferroelectric cathode is studied in a free-electron maser (FEM) experiment. In this gun, the electrons are separated from the cathode surface plasma, and are accelerated in two stages. The electron energy-spread is reduced sufficiently for an FEM operation in the microwave regime. A 14 keV, 1-2 A e-beam is obtained in a 0.1-2.1 μs pulse width. The pulse repetition frequency attains 3.1 MHz in ∼50% duty-cycle. This gun is implemented in an FEM oscillator experiment operating around 3 GHz. The paper presents experimental results and discusses the applicability of ferroelectric guns in free-electron laser devices

  12. A ferroelectric electron gun in a free-electron maser experiment

    CERN Document Server

    Einat, M; Rosenman, G

    2002-01-01

    An electron-gun based on a ferroelectric cathode is studied in a free-electron maser (FEM) experiment. In this gun, the electrons are separated from the cathode surface plasma, and are accelerated in two stages. The electron energy-spread is reduced sufficiently for an FEM operation in the microwave regime. A 14 keV, 1-2 A e-beam is obtained in a 0.1-2.1 mu s pulse width. The pulse repetition frequency attains 3.1 MHz in approx 50% duty-cycle. This gun is implemented in an FEM oscillator experiment operating around 3 GHz. The paper presents experimental results and discusses the applicability of ferroelectric guns in free-electron laser devices.

  13. NASA-DoD Lead-Free Electronics Project

    Science.gov (United States)

    Kessel, Kurt

    2011-01-01

    Original Equipment Manufacturers (OEMs). depots. and support contractors have to be prepared to deal with an electronics supply chain thaI increasingly provides parts with lead-free finishes. some labeled no differently and intenningled with their SnPb counterparts. Allowance oflead-free components presents one of the greatest risks to the reliability of military and aerospace electronics. The introduction of components with lead-free lenninations, tennination finishes, or circuit boards presents a host of concerns to customers. suppliers, and maintainers of aerospace and military electronic systems such as: 1. Electrical shorting due to tin whiskers; 2. Incompatibility oflead-free processes and parameters (including higher melting points of lead-free alloys) with other materials in the system; and 3. Unknown material properties and incompatibilities that could reduce solder joint re liability.

  14. Determination of authenticity of brand perfume using electronic nose prototypes

    International Nuclear Information System (INIS)

    Gebicki, Jacek; Szulczynski, Bartosz; Kaminski, Marian

    2015-01-01

    The paper presents the practical application of an electronic nose technique for fast and efficient discrimination between authentic and fake perfume samples. Two self-built electronic nose prototypes equipped with a set of semiconductor sensors were employed for that purpose. Additionally 10 volunteers took part in the sensory analysis. The following perfumes and their fake counterparts were analysed: Dior—Fahrenheit, Eisenberg—J’ose, YSL—La nuit de L’homme, 7 Loewe and Spice Bomb. The investigations were carried out using the headspace of the aqueous solutions. Data analysis utilized multidimensional techniques: principle component analysis (PCA), linear discrimination analysis (LDA), k-nearest neighbour (k-NN). The results obtained confirmed the legitimacy of the electronic nose technique as an alternative to the sensory analysis as far as the determination of authenticity of perfume is concerned. (paper)

  15. Determination of authenticity of brand perfume using electronic nose prototypes

    Science.gov (United States)

    Gebicki, Jacek; Szulczynski, Bartosz; Kaminski, Marian

    2015-12-01

    The paper presents the practical application of an electronic nose technique for fast and efficient discrimination between authentic and fake perfume samples. Two self-built electronic nose prototypes equipped with a set of semiconductor sensors were employed for that purpose. Additionally 10 volunteers took part in the sensory analysis. The following perfumes and their fake counterparts were analysed: Dior—Fahrenheit, Eisenberg—J’ose, YSL—La nuit de L’homme, 7 Loewe and Spice Bomb. The investigations were carried out using the headspace of the aqueous solutions. Data analysis utilized multidimensional techniques: principle component analysis (PCA), linear discrimination analysis (LDA), k-nearest neighbour (k-NN). The results obtained confirmed the legitimacy of the electronic nose technique as an alternative to the sensory analysis as far as the determination of authenticity of perfume is concerned.

  16. Dominance of IMP-4-Producing Enterobacter cloacae among Carbapenemase-Producing Enterobacteriaceae in Australia

    Science.gov (United States)

    Townell, Nicola; Nimmo, Graeme R.; George, Narelle M.; Robson, Jennifer; Vohra, Renu; Davis, Louise; Heney, Claire; Paterson, David L.

    2015-01-01

    The prevalence of carbapenemase-producing Enterobacteriaceae (CPE) has been increasing worldwide. blaIMP has been reported to be the predominant carbapenemase-encoding gene within Enterobacteriaceae in Australia. However, there are limited data currently available on CPE from Queensland, Australia. A total of 58 CPE isolates were isolated between July 2009 and March 2014 from Queensland hospitals. The clonality of isolates was determined by Diversilab repetitive sequence-based PCR. The isolates were investigated for the resistance mechanisms carbapenemase, extended-spectrum β-lactamase, and AmpC β-lactamase and for aminoglycoside resistance and plasmid-mediated quinolone resistance genes by PCR. The plasmid types associated with carbapenemase-encoding genes were characterized. The majority of the CPE were Enterobacter cloacae (n = 29). The majority of Queensland CPE isolates were IMP producers and comprised 11 species (n = 48). Nine NDM-producing Enterobacteriaceae were identified. One NDM-producing Klebsiella pneumoniae isolate coproduced OXA-48. One K. pneumoniae isolate was an OXA-181 producer. The incidence of IMP producers increased significantly in 2013. blaIMP-4 was found in all IMP-producing isolates. blaTEM, qnrB, and aacA4 were common among IMP-4 producers. The HI2 (67%) and L/M (21%) replicons were associated with blaIMP-4. All HI2 plasmids were of sequence type 1 (ST1). All but one of the NDM producers possessed blaCTX-M-15. The 16S rRNA methylase genes found among NDM producers were armA, rmtB, rmtC, and rmtF. The substantial increase in the prevalence of CPE in Queensland has been associated mainly with the emergence E. cloacae strains possessing HI2 plasmids carrying blaIMP-4 over the past 2 years. The importation of NDM producers and/or OXA-48-like producers in patients also contributed to the increased emergence of CPE. PMID:25918153

  17. IMP3 RNP safe houses prevent miRNA-directed HMGA2 mRNA decay in cancer and development

    DEFF Research Database (Denmark)

    Jønson, Lars; Christiansen, Jan; Hansen, Thomas van Overeem

    2014-01-01

    by let-7, and let-7 antagomiRs make HMGA2 refractory to IMP3. Removal of let-7 target sites eliminates IMP3-dependent stabilization, and IMP3-containing bodies are depleted of Ago1-4 and miRNAs. The relationship between Hmga2 mRNA and IMPs also exists in the developing limb bud, where IMP1-deficient...... that IMP3 RNPs may function as cytoplasmic safe houses and prevent miRNA-directed mRNA decay of oncogenes during tumor progression....

  18. Smith-Purcell free-electron laser

    International Nuclear Information System (INIS)

    Woods, K.J.; Walsh, J.E.

    1995-01-01

    The term Smith-Purcell free electron laser can be employed generally to describe any coherent radiation source in which a diffraction grating is used to couple an electron beam with the electromagnetic field. To date, most practical developments of this concept have focused on devices which operate in the millimeter spectral regime. In this paper construction of a Smith-Purcell free-electron laser operating in the far-infrared (FIR) region using a novel resonator cavity design and the electron beam from a low energy (0.5-5 MeV) radio-frequency accelerator will be discussed. A tunable source in this region would have many applications and since the beam energy is low, the small size and low overall cost of such a device would make it a laboratory instrument. Current projects which are progressing towards developing a FIR source are the programs at Stanford and CREOL. Both of these projects are using permanent magnet undulators to couple the electron beam with the electromagnetic field. An alternative approach is to use an electron beam passing over a diffraction grating as the radiating mechanism. This phenomenon is known as Smith-Purcell radiation and was first demonstrated for incoherent emission at visible wavelengths. The addition of feedback enhances the stimulated component of the emission which leads to the growth of coherence. Recent calculations for spontaneous emission have shown that the wiggler parameter and the grating efficiency are analogous. This result has important implications for the development of a Smith-Purcell FEL because a grating based free-electron laser would offer a greater range of tunability at a lower cost than its wiggler based counterpart

  19. Comparison of FDG-PET and IMP-SPECT in patients with dementia with Lewy bodies

    International Nuclear Information System (INIS)

    Ishii, Kazunari; Hosaka, Kayo; Mori, Tetsuya; Mori, Etsuro

    2004-01-01

    To investigate regional differences in cerebral glucose metabolism and blood flow of dementia with Lewy bodies (DLB), we studied 7 subjects with DLB and 20 normal controls using F-18 fluorodeoxyglucose (FDG) and positron emission tomography (PET) and then examined the same 7 subjects and 20 other normal controls with I-123 iodoamphetamine (IMP) and single photon emission computed tomography (SPECT). The anatomically standardized images were produced with NEUROSTAT and the regional relative metabolic and perfusional values were calculated. The mean reduction ratios of FDG uptake in the DLB group relative to the mean normal controls in the parietal lobe and occipital lobe were 0.72 and 0.83, respectively, while the corresponding mean reduction ratios of IMP uptake were 0.81 and 0.88, respectively. In the DLB group, parietal FDG uptake was significantly lower than parietal IMP uptake (p<0.05), occipital FDG uptake was significantly lower than occipital IMP uptake (p<0.05), and parietal IMP uptake was significantly lower than occipital IMP uptake (p<0.01), but there was no difference between parietal and occipital FDG uptake. Our findings suggest that parietal metabolism and perfusion are severely affected in DLB patients, though the occipital metabolic and perfusional reduction is thought to be a feature of DLB. FDG-PET is thought to be superior to IMP-SPECT in detecting functional changes in the DLB brain. (author)

  20. Biological applications of ultraviolet free-electron lasers

    International Nuclear Information System (INIS)

    Sutherland, J.C.

    1997-10-01

    This review examines the possibilities for biological research using the three ultraviolet free-electron lasers that are nearing operational status in the US. The projected operating characteristics of major interest in biological research of the free-electron lasers at Brookhaven National Laboratory, the Thomas Jefferson National Accelerator Facility, and Duke University are presented. Experimental applications in the areas of far- and vacuum ultraviolet photophysics and photochemistry, structural biology, environmental photobiology, and medical research are discussed and the prospects for advances in these areas, based upon the characteristics of the new ultraviolet free-electron lasers, are evaluated

  1. Quantitative 123I IMP and 99mTc HMPAO imaging in the dog following cocaine administration

    International Nuclear Information System (INIS)

    Susskind, Herbert; Weber, David A.; Ivanovic, Marija; Wong, Christopher T.C.; Haan, Constance E. de; Gavin, Patrick R.

    1996-01-01

    SPECT and associated imaging procedures were used in beagle dogs to evaluate the uptake, distribution, and clearance properties of i.v.-injected 123 I IMP (IMP) and 99m Tc HMPAO (HMPAO) in the brain, lungs, liver, and kidneys; (2) quantify the acute effects (after 15 sec) of very low doses (0.5 or 1.0 mg/kg) cocaine on the kinetics and localization properties of IMP and HMPAO; and (3) evaluate comparative imaging properties of IMP and HMPAO for measuring regional cerebral blood flow (rCBF). Regional and global uptake and localization of IMP or HMPAO were evaluated in control studies using dynamic planar (0-30 min) and SPECT imaging (at 35 min). The regional distribution properties of IMP and HMPAO in the brain were estimated from regions of interest (ROIs) drawn around anatomic structures on MR slices and manually registered with corresponding SPECT slices. Cocaine significantly reduced the 30-min IMP uptake in the brain and lungs by ∼15%, but only slightly changed HMPAO uptake in the brain and other organs. In the control studies, the respective uptakes of IMP in the brain and lungs were 9 and 39% greater (p < 0.01) than those of HMPAO. In control SPECT studies, the highest uptake of IMP was observed in the thalamus and progressively less activity was observed in the parietal lobe, frontal lobe, cerebellum, occipital lobe, and entire brain; activity in the olfactory bulb was lower than in all other regions. Cocaine reduced IMP uptake in the cerebellum (p < 0.01), occipital lobe (p < 0.01), and entire brain (p < 0.05). IMP uptake (cpm/pixel-mCi) in the different brain regions was 1.3 to 2.1 times greater than that of HMPAO (p < 0.001). HMPAO uptake was more homogeneous throughout the gray matter of the brain; no significant uptake differences were observed among flagged regions. Results indicate that single, acute doses of cocaine, 0.5 and 1.0 mg/kg, significantly altered the uptake and localization properties of IMP in the dog's brain, lungs, liver, and kidneys

  2. Electron signals in the Forward Calorimeter prototype for ATLAS

    International Nuclear Information System (INIS)

    Armitage, J C; Artamonov, A; Babukhadia, L; Dixit, M; Embry, T M; Epshteyn, V; Estabrooks, P; Gravelle, P; Hamm, J; Khovansky, V; Koolbeck, D A; Krieger, P; Loch, P; Losty, M; Mayer, J; Mazini, R; Oakham, F Gerald; O'Neill, M; Orr, R S; Rutherfoord, J P; Ryabinin, M; Savine, A; Seely, C Jason; Shatalov, P; Shaver, L S; Shupe, M A; Stairs, G; Tompkins, D; Trischuk, W; Vincent, K; Zaitsev, V

    2007-01-01

    A pre-production prototype of the Forward Calorimeter (FCal) for the ATLAS detector presently under construction at the Large Hadron Collider (LHC) at CERN, Geneva, Switzerland, was exposed to electrons in the momentum range from 20 to 200 GeV/c in a test beam experiment at CERN in 1998. The measured performance, including a signal linearity within about ±1% and a high energy limit in the relative energy resolution of about 4%, meets the expectations for this kind of calorimeter, and exceeds the physics requirements for successful application in ATLAS

  3. Serial lung imaging with 123I-IMP in localized pulmonary lesions

    International Nuclear Information System (INIS)

    Nakajo, Masayuki; Shimada, Jurio; Shimozono, Michiko; Uchiyama, Noriaki; Hiraki, Yoshiyuki; Shinohara, Shinji.

    1988-01-01

    123 I-IMP (N-isopropyl-p-[ 123 I]-iodoamphetamine) dynamic (1 frame/min for 25 mins), 30-min and 4-hr static lung imaging was performed in a total of 65 patients with roentgenographic evidence of localized pulmonary lesion (12 with pneumonia, one with lung abscess, 5 with pulmonary tuberculosis, 3 with pneumoconiosis, one with lung fluke disease and 43 with various histological types of primary lung cancer). The findings in 65 of 70 (95 %) lesions in the initial 1 or 2-min dynamic 123 I-IMP images were analogous to those obtained by 99m Tc-MAA lung perfusion imaging and decreased activity was observed in 68 of 70 (97 %) lesions, suggesting that the initial images mainly reflected the relative distribution of pulmonary arterial blood flow. However, 123 I-IMP accumulated differently according to the pathological conditions afterwards. Decrease activity from 123 I-IMP was contineously observed in a cavity of the lung abscess, 2 of 2 tuberculomas, 3 of 7 large nodules of pneumoconiosis and all of the 42 cancerous lesions which were possible to be evaluated. Gradual increased in activity relative to that of ''normal lung fields'' was observed in all 14 lesions of pneumonia; pneumonic lesions of the lung abscess, tuberculosis and lung fluke disease; 4 of 7 large nodules of pneumoconiosis; all of 8 atelectatic lesions and 32 of 44 areas surrounding cancers (most of them had roentgenographic evidence of infiltrating shadows). Thus 123 I-IMP accumulated increasingly in pneumonic and atelectatic lesions, while it appeared not to accumulate in such lesions replacing lung tissues as cavity, caseous and fibrous lesions and primary lung cancers. 123 I-IMP can be used as a new lung imaging agent to provide diagnostic informations on the property of pulmonary lesions. (author)

  4. Undulators and free-electron lasers

    CERN Document Server

    Luchini, P

    1990-01-01

    This book is a reference text for all those working in free-electron laser research as well as being a learning aid for physicists and graduate students who wish an introduction to this field. Only a basic understanding of relativistic mechanics and electromagnetism is presupposed. After an overview of early developments and general principles of operation, the different models that can be used to describe free-electron lasers are presented, organized according to their range of applicability. The relevent conceptual and mathematical constructs are built up from first principles with attention to obtaining the practically important results in a simple but rigorous way. Interaction of the undulator with the driving electron accelerator and the laser cavity and design of undulator magnets are treated and an overview is given of some typical experiments.

  5. A Carbapenem-Resistant Pseudomonas aeruginosa Isolate Harboring Two Copies of blaIMP-34 Encoding a Metallo-β-Lactamase.

    Directory of Open Access Journals (Sweden)

    Tatsuya Tada

    Full Text Available A carbapenem-resistant strain of Pseudomonas aeruginosa, NCGM1984, was isolated in 2012 from a hospitalized patient in Japan. Immunochromatographic assay showed that the isolate was positive for IMP-type metallo-β-lactamase. Complete genome sequencing revealed that NCGM1984 harbored two copies of blaIMP-34, located at different sites on the chromosome. Each blaIMP-34 was present in the same structures of the class 1 integrons, tnpA(ISPa7-intI1-qacG-blaIMP-34-aac(6'-Ib-qacEdelta1-sul1-orf5-tniBdelta-tniA. The isolate belonged to multilocus sequence typing ST235, one of the international high-risk clones. IMP-34, with an amino acid substitution (Glu126Gly compared with IMP-1, hydrolyzed all β-lactamases tested except aztreonam, and its catalytic activities were similar to IMP-1. This is the first report of a clinical isolate of an IMP-34-producing P. aeruginosa harboring two copies of blaIMP-34 on its chromosome.

  6. Interpretation criteria for FDG PET/CT in multiple myeloma (IMPeTUs): final results. IMPeTUs (Italian myeloma criteria for PET USe).

    Science.gov (United States)

    Nanni, Cristina; Versari, Annibale; Chauvie, Stephane; Bertone, Elisa; Bianchi, Andrea; Rensi, Marco; Bellò, Marilena; Gallamini, Andrea; Patriarca, Francesca; Gay, Francesca; Gamberi, Barbara; Ghedini, Pietro; Cavo, Michele; Fanti, Stefano; Zamagni, Elena

    2018-05-01

    ᅟ: FDG PET/CT ( 18 F-fluoro-deoxy-glucose positron emission tomography/computed tomography) is a useful tool to image multiple myeloma (MM). However, simple and reproducible reporting criteria are still lacking and there is the need for harmonization. Recently, a group of Italian nuclear medicine experts defined new visual descriptive criteria (Italian Myeloma criteria for Pet Use: IMPeTUs) to standardize FDG PET/CT evaluation in MM patients. The aim of this study was to assess IMPeTUs reproducibility on a large prospective cohort of MM patients. Patients affected by symptomatic MM who had performed an FDG PET/CT at baseline (PET0), after induction (PET-AI), and the end of treatment (PET-EoT) were prospectively enrolled in a multicenter trial (EMN02)(NCT01910987; MMY3033). After anonymization, PET images were uploaded in the web platform WIDEN® and hence distributed to five expert nuclear medicine reviewers for a blinded independent central review according to the IMPeTUs criteria. Consensus among reviewers was measured by the percentage of agreement and the Krippendorff's alpha. Furthermore, on a patient-based analysis, the concordance among all the reviewers in terms of positivity or negativity of the FDG PET/CT scan was tested for different thresholds of positivity (Deauville score (DS 2, 3, 4, 5) for the main parameters (bone marrow, focal score, extra-medullary disease). Eighty-six patients (211 FDG PET/CT scans) were included in this analysis. Median patient age was 58 years (range, 35-66 years), 45% were male, 15% of them were in stage ISS (International Staging System) III, and 42% had high-risk cytogenetics. The percentage agreement was superior to 75% for all the time points, reaching 100% of agreement in assessing the presence skull lesions after therapy. Comparable results were obtained when the agreement analysis was performed using the Krippendorff's alpha coefficient, either in every single time point of scanning (PET0, PET-AI or PET-EoT) or

  7. cIMP synthesized by sGC as a mediator of hypoxic contraction of coronary arteries.

    Science.gov (United States)

    Chen, Zhengju; Zhang, Xu; Ying, Lei; Dou, Dou; Li, Yanhui; Bai, Yun; Liu, Juan; Liu, Limei; Feng, Han; Yu, Xiaoxing; Leung, Susan Wai-Sum; Vanhoutte, Paul M; Gao, Yuansheng

    2014-08-01

    cGMP is considered the only mediator synthesized by soluble guanylyl cyclase (sGC) in response to nitric oxide (NO). However, purified sGC can synthesize several other cyclic nucleotides, including inosine 3',5'-cyclic monophosphate (cIMP). The present study was designed to determine the role of cIMP in hypoxic contractions of isolated porcine coronary arteries. Vascular responses were examined by measuring isometric tension. Cyclic nucleotides were assayed by HPLC tandem mass spectroscopy. Rho kinase (ROCK) activity was determined by measuring the phosphorylation of myosin phosphatase target subunit 1 using Western blot analysis and an ELISA kit. The level of cIMP, but not that of cGMP, was elevated by hypoxia in arteries with, but not in those without, endothelium [except if treated with diethylenetriamine (DETA) NONOate]; the increases in cIMP were inhibited by the sGC inhibitor 1H-[1,2,4]oxadiazolo[4,3,-a]quinoxalin-1-one (ODQ). Hypoxia (Po2: 25-30 mmHg) augmented contractions of arteries with and without endothelium if treated with DETA NONOate; these hypoxic contractions were blocked by ODQ. In arteries without endothelium, hypoxic augmentation of contraction was also obtained with exogenous cIMP. In arteries with endothelium, hypoxic augmentation of contraction was further enhanced by inosine 5'-triphosphate, the precursor for cIMP. The augmentation of contraction caused by hypoxia or cIMP was accompanied by increased phosphorylation of myosin phosphatase target subunit 1 at Thr(853), which was prevented by the ROCK inhibitor Y-27632. ROCK activity in the supernatant of isolated arteries was stimulated by cIMP in a concentration-dependent fashion. These results demonstrate that cIMP synthesized by sGC is the likely mediator of hypoxic augmentation of coronary vasoconstriction, in part by activating ROCK. Copyright © 2014 the American Physiological Society.

  8. Brain imaging with 123I-IMP-SPECT in migraine between attacks

    International Nuclear Information System (INIS)

    Schlake, H.P.; Boettger, I.G.G.; Grotemeyer, K.H.; Husstedt, I.W.

    1989-01-01

    123 I-IMP-SPECT brain imaging was performed in patients with classic migraine (n = 5) and migraine accompagnee (n = 18) during the headache-free interval. A regional reduction of tracer uptake into brain was observed in all patients with migraine accompagnee, while in patients with classic migraine only one case showed an area of decreased activity. The most marked alteration was found in a patient with persisting neurological symptoms (complicated migraine). In most cases the areas of decreased tracer uptake corresponded to headache localization as well as to topography of neurologic symptoms during migraine attacks. It may be concluded that migraine attacks occur in connection with exacerbations of preexisting changes of cerebral autoregulation due to endogenous or exogenous factors

  9. Brain scintigraphy with N-isopropyl [123I] p-iodoamphetamine (123I IMP) in patients with various cerebral diseases

    International Nuclear Information System (INIS)

    Oshibuchi, Masao; Kanda, Teturo; Sato, Mitutaka; Miyagi, Jun; Ohtake, Hisasi; Suhara, Tetuya; Mori, Atuyoshi.

    1988-01-01

    Single photon emission computed tomography(SPECT) with N-isopropyl-p-[ 123 I]-iodoamphet amine(IMP) was utilized in 99 patients with various cerebral diseases and 3 healthy volunteers. By IMP SPECT, demaged area was observed as wider and faster in time than with X-ray CT or MRI. The nidus was visualized as defect of IMP in cases of AVM. In patients with subarachnoid hemorrhage, IMP SPECT was more useful for detecting of post hemorrhagic symptomatic vasospasm compared to X-ray CT or MRI. IMP SPECT was also useful to the differential diagnosis in cases of dementia. Grossed cerebellar diaschisis(CCD) was observed in 26 out of 67 cases (39 %) studied. In epilepsy the low uptake areas of IMP in the bilateral occipital lobes were observed in IMP SPECT. (author)

  10. Imp2 regulates GBM progression by activating IGF2/PI3K/Akt pathway.

    Science.gov (United States)

    Mu, Qingchun; Wang, Lijun; Yu, Fengbo; Gao, Haijun; Lei, Ting; Li, Peiwen; Liu, Pengfei; Zheng, Xu; Hu, Xitong; Chen, Yong; Jiang, Zhenfeng; Sayari, Arash J; Shen, Jia; Huang, Haiyan

    2015-01-01

    Glioblastomas multiforme (GBM) are the most frequently occurring malignant brain cancers. Treatment for GBM consists of surgical resection and subsequent adjuvant radiation therapy and chemotherapy. Despite this, GBM patient survival is limited to 12-15 months, and researchers are continually trying to develop improved therapy options. Insulin-like growth factor 2 mRNA-binding protein 2 (Imp2) is known to be upregulated in many cancers and is known to regulate the signaling activity of insulin-like growth factor 2 (IGF2). However, relatively little is known about its role in malignant development of GBM. In this study, we first found Imp2 is upregulated in GBM tissues by using clinical samples and public database search. Studies with loss and gain of Imp2 expression in in vitro GBM cell culture system demonstrated the role of Imp2 in promoting GBM cell proliferation, migration, invasion and epithelial-to-mesenchymal transition (EMT). Additionally, our results show that Imp2 regulates the activity of IGF2, which further activates PI3K/Akt signaling, thereby to promote GBM malignancy. Inhibition of Imp2 was also found to sensitize GBM to temozolomide treatment. These observations add to the current knowledge of GBM biology, and may prove useful in development of more effective GBM therapy.

  11. Observations of a low-frequency cutoff in magnetospheric radio noise received on Imp 6

    International Nuclear Information System (INIS)

    Vesecky, J.F.; Frankel, M.S.

    1975-01-01

    Observations of magnetospheric radio noise by the Goddard Space Flight Center radio experiment on the Imp 6 spacecraft have revealed a quasi-continuous component at frequencies between 30 and 110 kHz. When the spacecraft is in the interplanetary medium or the magnetosheath, a low-frequency cutoff often characterizes the otherwise power law (f - /sup alpha/) spectrum of this noise. A positive correlation is observed between this cutoff frequency f) and the solar wind plasma frequency f), deduced from the Los Alamos plasma experiment on the same spacecraft; on the average, f)approx. =1.3f). If one pictures the magnetosheath as a homogeneous layer of plasma lying between the radio noise source (at Lapprox.4--7) and the spacecraft in the interplanetary medium and having an electron density 2--3 times that of the solar wind, then one will expect f)approximately-greater-than2 1 / 2 f)--3 1 / 2 f). Within the limits of experimental error this simple model correctly accounts for the observations. A rough calculation shows that radio wave scattering by electron density fluctuations in the magnetosheath plasma is likely to be important for frequencies below 200 kHz. However, the effects of such scattering cannot be detected in the Imp 6 observations considered here because neither concurrent measurements nor sufficiently accurate models of the necessar []magnetosheath plasma parameters are presently available

  12. Cell-free protein synthesis enabled rapid prototyping for metabolic engineering and synthetic biology

    Directory of Open Access Journals (Sweden)

    Lihong Jiang

    2018-06-01

    Full Text Available Advances in metabolic engineering and synthetic biology have facilitated the manufacturing of many valuable-added compounds and commodity chemicals using microbial cell factories in the past decade. However, due to complexity of cellular metabolism, the optimization of metabolic pathways for maximal production represents a grand challenge and an unavoidable barrier for metabolic engineering. Recently, cell-free protein synthesis system (CFPS has been emerging as an enabling alternative to address challenges in biomanufacturing. This review summarizes the recent progresses of CFPS in rapid prototyping of biosynthetic pathways and genetic circuits (biosensors to speed up design-build-test (DBT cycles of metabolic engineering and synthetic biology. Keywords: Cell-free protein synthesis, Metabolic pathway optimization, Genetic circuits, Metabolic engineering, Synthetic biology

  13. Preparatory procedure and equipment for the European x-ray free electron laser cavity implementation

    Directory of Open Access Journals (Sweden)

    D. Reschke

    2010-07-01

    Full Text Available The European x-ray free electron laser is under construction at Deutsches Elektronen-Synchrotron (DESY. The electron beam energy of up to 17.5 GeV will be achieved by using superconducting accelerator technology. Final prototyping, industrialization, and new infrastructure are the actual challenges with respect to the accelerating cavities. This paper describes the preparation strategy optimized for the cavity preparation procedure in industry. For the industrial fabrication and preparation, several new hardware components have been already developed at DESY. The design and construction of a semiautomated rf-measurement machine for dumbbells and end groups are described. In a collaboration among FNAL, KEK, and DESY, an automatic cavity tuning machine has been designed and four machines are under construction. The functionality of these machines with special attention to safety aspects is described in this paper. A new high pressure rinsing system has been developed and is operational.

  14. Nonlinear theory of the free-electron laser

    International Nuclear Information System (INIS)

    Chian, A.C.-L.; Padua Brito Serbeto, A. de.

    1984-01-01

    A theory of Raman free-electron laser using a circularly polarized electromagnetic pump is investigated. Coupled wave equations that describe both linear and nonlinear evolution of stimulated Raman scattering are derived. The dispersion relation and the growth rate for the parametric instability are obtained. Nonlinear processes that may lead to saturation of the free-electron laser are discussed. (Author) [pt

  15. Serial lung imaging with /sup 123/I-IMP in localized pulmonary lesions

    Energy Technology Data Exchange (ETDEWEB)

    Nakajo, Masayuki; Shimada, Jurio; Shimozono, Michiko; Uchiyama, Noriaki; Hiraki, Yoshiyuki; Shinohara, Shinji.

    1988-05-01

    /sup 123/I-IMP (N-isopropyl-p-(/sup 123/I)-iodoamphetamine) dynamic (1 frame/min for 25 mins), 30-min and 4-hr static lung imaging was performed in a total of 65 patients with roentgenographic evidence of localized pulmonary lesion (12 with pneumonia, one with lung abscess, 5 with pulmonary tuberculosis, 3 with pneumoconiosis, one with lung fluke disease and 43 with various histological types of primary lung cancer). The findings in 65 of 70 (95 %) lesions in the initial 1 or 2-min dynamic /sup 123/I-IMP images were analogous to those obtained by /sup 99m/Tc-MAA lung perfusion imaging and decreased activity was observed in 68 of 70 (97 %) lesions, suggesting that the initial images mainly reflected the relative distribution of pulmonary arterial blood flow. However, /sup 123/I-IMP accumulated differently according to the pathological conditions afterwards. Decrease activity from /sup 123/I-IMP was contineously observed in a cavity of the lung abscess, 2 of 2 tuberculomas, 3 of 7 large nodules of pneumoconiosis and all of the 42 cancerous lesions which were possible to be evaluated. Gradual increased in activity relative to that of ''normal lung fields'' was observed in all 14 lesions of pneumonia; pneumonic lesions of the lung abscess, tuberculosis and lung fluke disease; 4 of 7 large nodules of pneumoconiosis; all of 8 atelectatic lesions and 32 of 44 areas surrounding cancers (most of them had roentgenographic evidence of infiltrating shadows). Thus /sup 123/I-IMP accumulated increasingly in pneumonic and atelectatic lesions, while it appeared not to accumulate in such lesions replacing lung tissues as cavity, caseous and fibrous lesions and primary lung cancers. /sup 123/I-IMP can be used as a new lung imaging agent to provide diagnostic informations on the property of pulmonary lesions.

  16. Commissioning of the JAERI free electron laser

    International Nuclear Information System (INIS)

    Minehara, E.J.; Nagai, R.; Sawamura, M.

    1993-01-01

    We have developed, and constructed a prototype for a quasi-cw, and high-average power free electron laser driven by a 15MeV superconducting rf linac at Tokai, JAERI. In designing a high power FEL, there are many available design options to generate the required power output. By applying the superconducting rf linac driver, some of the options relating to the FEL itself may be relaxed by transferring design difficulties to the driver. Because wall losses become minimal in the superconducting accelerator cavity, very long pulse or quasi-cw, and resultant high average power may be readily attained at the JAERI superconducting rf linac FEL. In 1992 Japanese fiscal year, we have successfully demonstrated better cryogenic (stand-by loss<3.5W at 4.5K) and accelerating fields' performances (Eacc=7-9.4MV/m and Q=1-2x10+9) of four JAERI superconducting accelerator modules, and installed them in the FEL accelerator vault. In 1993, Optical resonators and beam transport systems, which have been already assembled, are now under commissioning. A description and the latest results of the JAERI super-conducting rf linac FEL will be discussed in comparison with a normal-conducting one, and reported in the symposium. (author)

  17. Distinct Signaling Roles of cIMP, cCMP, and cUMP.

    Science.gov (United States)

    Seifert, Roland

    2016-10-04

    The cyclic purine nucleotide cIMP and the cyclic pyrimidine nucleotides cCMP and cUMP are emerging second messengers. These cNMPs show different biological effects, but the molecular mechanisms remain elusive. In this issue of Structure, Ng et al. (2016) provide structural evidence for distinct interactions of cIMP, cCMP, and cUMP with ion channels. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Demonstration of a Prototype Hydrogen Sensor and Electronics Package - Progress Report 2

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Amanda S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Brosha, Eric [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-14

    This is the second progress report on the demonstration of a prototype hydrogen sensor and electronics package. It goes into detail about the five tasks, four of which are already completed as of August 2016, with the final to be completed by January 26, 2017. Then the budget is detailed along with the planned work for May 27, 2016 to July 27, 2016.

  19. N-isopropyl-p-[I123] iodoamphetamine single photon emission computed tomography (I123-IMP SPECT) and child neurology

    International Nuclear Information System (INIS)

    Tada, Hiroshi; Morooka, Keiichi; Arimoto, Kiyoshi; Matsuo, Takiko; Takagi, Kazue; Yanagawa, Etsuko

    1992-01-01

    We studied the clinical usefulness of I 123 -IMP SPECT in 50 pediatric patients with CNS disorders, which were categorized into the convulsive disorder group (n=20), the cerebrovascular disorder group (n=10), the acute encephalopathy or CNS infection group (n=10), the metabolic or degenerative disorder group (n=6), the congenital abnormality group (n=2) and the migraine group (n=2). The findings obtained were compared with those of cranial CT. I 123 -IMP SPECT revealed abnormal findings in 45 out of the 50 patients (90%), although cranial CT showed abnormal findings in only 24 patients (48%). This difference was statistically significant (p 123 -IMP SPECT showed focal abnormalities in 26 patients (93%). Moreover in many patients with focal neurological abnormalities, we found focal abnormalities of I 123 -IMP SPECT related with neurological abnormalities of the patients. From these findings, we think I 123 -IMP SPECT might be superior to CT scanning in examining a localized lesion. It was found that in many patients with focal abnormalities in CT scanning, I 123 -IMP SPECT showed larger abnormalities in CT scanning. By using I 123 -IMP SPECT we might be able to study the blood perfusional state surrounding the abnormal area shown by CT. In 3 patients with acute cerebrovascular disorders, I 123 -IMP SPECT revealed abnormal findings 3 to 11 days earlier than cranial CT. I 123 -IMP SPECT might be useful for early recognition of the pathological state. From these experiences, we concluded that I 123 -IMP SPECT was useful for studying the pathophysiology of CNS disorders in children. (author)

  20. Construction of a full-length prototype of the BESIII drift chamber and on-detector test for the BESIII drift chamber electronics

    International Nuclear Information System (INIS)

    Qin Zhonghua; Wu Linghui; Liu Jianbei; Chinese Academy of Sciences, Beijing; Yan Zhikang; Hunan Univ., Changsha; Chen Yuanbo; Chen Chang; Xu Meihang; Wang Lan; Ma Xiaoyan; Jin Yan; Liu Rongguang; Tang Xiao; Zhang Guifang; Zhu Qiming; Sheng Huayi; Zhu Kejun

    2007-01-01

    A full-length prototype of the BESIII drift chamber was built. The experience gained on gas sealing, high voltage supply and front-end electronics installation should be greatly beneficial to the successful construction of the BESIII drift chamber. An on-detector test of the BESIII drift chamber electronics was carried out with the constructed prototype chamber. The noise performance, drift time and charge measurements, and electronics gains were examined specifically. The final test results indicate that the electronics have a good performance and can satisfy their design requirements. (authors)

  1. Integrated Micro-Power System (IMPS) Development at NASA Glenn Research Center

    Science.gov (United States)

    Wilt, David; Hepp, Aloysius; Moran, Matt; Jenkins, Phillip; Scheiman, David; Raffaelle, Ryne

    2003-01-01

    Glenn Research Center (GRC) has a long history of energy related technology developments for large space related power systems, including photovoltaics, thermo-mechanical energy conversion, electrochemical energy storage. mechanical energy storage, power management and distribution and power system design. Recently, many of these technologies have begun to be adapted for small, distributed power system applications or Integrated Micro-Power Systems (IMPS). This paper will describe the IMPS component and system demonstration efforts to date.

  2. Maxwell-Like Equations for Free Dirac Electrons

    Science.gov (United States)

    Bruce, S. A.

    2018-03-01

    In this article, we show that the wave equation for a free Dirac electron can be represented in a form that is analogous to Maxwell's electrodynamics. The electron bispinor wavefunction is explicitly expressed in terms of its real and imaginary components. This leads us to incorporate into it appropriate scalar and pseudo-scalar fields in advance, so that a full symmetry may be accomplished. The Dirac equation then takes on a form similar to that of a set of inhomogeneous Maxwell's equations involving a particular self-source. We relate plane wave solutions of these equations to waves corresponding to free Dirac electrons, identifying the longitudinal component of the electron motion, together with the corresponding Zitterbewegung ("trembling motion").

  3. Comparison of I-123 IMP cerebral uptake and MR spectroscopy following experimental carotid occlusion

    International Nuclear Information System (INIS)

    Holman, B.L.; Jolesz, F.A.; Polak, J.F.; Kronauge, J.F.; Adams, D.F.

    1985-01-01

    Both I-123 IMP scintigraphy and MRI have been suggested as sensitive detectors of changes shortly after acute cerebral infarction. We compared the uptake of N-isopropyl I-123 p-iodoamphetamine (IMP) and MR spectroscopy of the brain after internal carotid artery ligation. Thirteen gerbils were lightly anesthetized with ether. After neck dissection, an internal carotid artery was occluded. After 2.8 hours, 100 muCi I-123 IMP was injected intravenously into the 13 experimental animals plus three controls. Seven gerbils remained asymptomatic while six developed hemiparesis. At 3 hours after ligation, the animals were killed. The brains were bisected and T1 and T2 relaxation times were determined for the right and left hemispheres by MR spectroscopy immediately after dissection. I-123 IMP uptake was then determined in the samples. Interhemispheric differences in uptake for I-123 IMP were 0.1 +/- 1.7% (SEM) in the control, 33.5 +/- 10% in the asymptomatic and 54.6 +/- 9.7% in the symptomatic animals. Significant differences were seen with I-123 IMP in 6/7 asymptomatic and 6/6 symptomatic animals. In conclusion, I-123 is more sensitive than T1 or T2 relaxation times for the detection of cerebral perfusion abnormalities. Prolongation in T1 and T2 relaxation times correlates closely with increased brain tissue water content and the development of symptoms, indicators of structural brain damage and probable infarction

  4. Electron response and e/h ratio of ATLAS barrel hadron prototype calorimeter

    International Nuclear Information System (INIS)

    Budagov, Yu.A.; Vinogradov, V.B.; Arkadov, V.V.; Karapetyan, G.V.

    1995-01-01

    The detailed information about electron response, electron energy resolution and e/h ratio as a function of incident energy E, impact point Z and incidence angle Θ of ATLAS iron-scintillator hadron prototype calorimeter with longitudinal tile configuration is presented. These results are based on electron and pion beams data of E=20, 50, 100, 150, 300 GeV at Θ=10 deg, 20 deg, 30 deg, which were obtained during test beam period in July 1995. The obtained calibration constant is used for muon response converting from pC to GeV. The results are compared with existing experimental data and with some Monte Carlo calculations. For some E, Θ, Z values the compensation (e/h=1) is observed. 23 refs., 18 figs., 9 tabs

  5. X-ray absorption spectroscopy using a self-seeded soft X-ray free-electron laser

    Energy Technology Data Exchange (ETDEWEB)

    Kroll, Thomas; Kern, Jan; Kubin, Markus; Ratner, Daniel; Gul, Sheraz; Fuller, Franklin D.; Löchel, Heike; Krzywinski, Jacek; Lutman, Alberto; Ding, Yuantao; Dakovski, Georgi L.; Moeller, Stefan; Turner, Joshua J.; Alonso-Mori, Roberto; Nordlund, Dennis L.; Rehanek, Jens; Weniger, Christian; Firsov, Alexander; Brzhezinskaya, Maria; Chatterjee, Ruchira; Lassalle-Kaiser, Benedikt; Sierra, Raymond G.; Laksmono, Hartawan; Hill, Ethan; Borovik, Andrew; Erko, Alexei; Föhlisch, Alexander; Mitzner, Rolf; Yachandra, Vittal K.; Yano, Junko; Wernet, Philippe; Bergmann, Uwe

    2016-01-01

    © 2016 Optical Society of America. X-ray free electron lasers (XFELs) enable unprecedented new ways to study the electronic structure and dynamics of transition metal systems. L-edge absorption spectroscopy is a powerful technique for such studies and the feasibility of this method at XFELs for solutions and solids has been demonstrated. However, the required x-ray bandwidth is an order of magnitude narrower than that of self-amplified spontaneous emission (SASE), and additional monochromatization is needed. Here we compare L-edge x-ray absorption spectroscopy (XAS) of a prototypical transition metal system based on monochromatizing the SASE radiation of the linac coherent light source (LCLS) with a new technique based on self-seeding of LCLS. We demonstrate how L-edge XAS can be performed using the self-seeding scheme without the need of an additional beam line monochromator. We show how the spectral shape and pulse energy depend on the undulator setup and how this affects the x-ray spectroscopy measurements.

  6. Evolution of Taste Compounds of Dezhou-Braised Chicken During Cooking Evaluated by Chemical Analysis and an Electronic Tongue System.

    Science.gov (United States)

    Liu, Dengyong; Li, Shengjie; Wang, Nan; Deng, Yajun; Sha, Lei; Gai, Shengmei; Liu, Huan; Xu, Xinglian

    2017-05-01

    This paper aimed to study the time course changes in taste compounds of Dezhou-braised chicken during the entire cooking process mainly consisting of deep-frying, high-temperature boiling, and low-temperature braising steps. For this purpose, meat samples at different processing stages were analyzed for 5'-nucleotides and free amino acids, and were also subjected to electronic tongue measurements. Results showed that IMP, Glu, Lys, and sodium chloride were the main compounds contributing to the taste attributes of the final product. IMP and Glu increased in the boiling step and remained unchanged in the following braising steps. Meanwhile, decrease in Lys content and increase in sodium chloride content were observed over time in both boiling and braising steps. Intensities for bitterness, saltiness, and Aftertaste-B obtained from the electronic tongue analysis were correlated with the concentrations of these above chemical compounds. Therefore, the electronic tongue system could be applied to evaluate the taste development of Dezhou-braised chicken during processing. © 2017 Institute of Food Technologists®.

  7. Quantum aspects of the free electron laser

    Energy Technology Data Exchange (ETDEWEB)

    Gaiba, R.

    2007-03-15

    We study the role of Quantum Mechanics in the physics of Free Electron Lasers. While the Free Electron Laser (FEL) is usually treated as a classical device, we review the advantages of a quantum formulation of the FEL. We then show the existence of a regime of operation of the FEL that can only be described using Quantum Mechanics: if the dimensionless quantum parameter anti {rho} is smaller than 1, then in the 1-dimensional approximation the Hamiltonian that describes the FEL becomes equivalent to the Hamiltonian of a two-level system coupled to a radiation field. We give analytical and numerical solutions for the photon statistics of a Free Electron Laser operating in the quantum regime under various approximations. Since in the quantum regime the momentum of the electrons is discrete, we give a description of the electrons in phase space by introducing the Discrete Wigner Function. We then drop the assumption of a mono-energetic electron beam and describe the general case of a initial electron energy spread G({gamma}). Numerical analysis shows that the FEL quantum regime is observed only when the width of the initial momentum distribution is smaller than the momentum of the emitted photons. Both the analytical results in the linear approximation and the numerical simulations show that only the electrons close to a certain resonant energy start to emit photons. This generates the so-called Hole-burning effect in the electrons energy distribution, as it can be seen in the simulations we provide. Finally, we present a brief discussion about a fundamental uncertainty relation that ties the electron energy spread and the electron bunching. (orig.)

  8. High-efficiency free-electron-laser experiments

    International Nuclear Information System (INIS)

    Boyer, K.; Brau, C.A.; Goldstein, J.C.; Hohla, K.L.; Newnam, B.E.; Stein, W.E.; Warren, R.W.; Winston, J.G.

    1983-01-01

    Experiments with a tapered-wiggler free-electron laser have demonstrated extraction of about 3% of the energy from the electron beam and measured the corresponding optical emission. These results are in excellent agreement with theory and represent an order-of-magnitude improvement over all previous results

  9. XUV/VUV free-electron laser oscillator

    International Nuclear Information System (INIS)

    Goldstein, J.C.; Newnam, B.E.; Cooper, R.K.; Comly, J.C. Jr.

    1984-04-01

    It is shown, from computations based on a detailed theoretical model, that modest improvements in electron beam and optical mirror technologies will enable a free-electron laser, driven by an rf linear accelerator, to operate in the 50 to 200-nm range of optical wavelengths. 10 references

  10. A comparison among 123I-IMP SPECT, EEG and MRI in patients with temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Tatsu, Yoshimitsu; Nishigaki, Hiroshi; Adachi, Itaru

    1994-01-01

    N-isopropyl-p-[ 123 I]iodoamphetamine ( 123 I-IMP) single photon emission computed tomography (SPECT), electroencephalography (EEG), and magnetic resonance imaging (MRI) were performed in 19 patients with temporal lobe epilepsy during interictal stage. MRI demonstrated abnormal signal in mesial temporal lobe (hippocampus) in 10 of 19 patients and 123 I-IMP SPECT showed a hypoperfusion area in 15 of 19 patients. When compared with EEG and MRI data, disagreement of the affected area was observed in 3 cases. In comparison of EEG and 123 I-IMP SPECT data, disagreement of the affected area was observed in 6 cases. Although there was no disagreement in comparison of MRI and 123 I-IMP SPECT. We made a reprojection data parallel to the hippocampus in 123 I-IMP SPECT. These data demonstrated obviously a hypoperfusion area around the hippocampus. In cases within one month from seizure attack, wide hypoperfusion area was showed on 123 I-IMP SPECT in comparison of abnormal signal area on MRI. It could be considered that a reprojection data parallel to the hippocampus was useful to know extent of hypoperfusion area in temporal lobe epilepsy. (author)

  11. Development of selective medium for IMP-type carbapenemase-producing Enterobacteriaceae in stool specimens.

    Science.gov (United States)

    Yamamoto, Norihisa; Kawahara, Ryuji; Akeda, Yukihiro; Shanmugakani, Rathina Kumar; Yoshida, Hisao; Hagiya, Hideharu; Hara, Naohiro; Nishi, Isao; Yukawa, Satomi; Asada, Rumiko; Sasaki, Yumi; Maeda, Kazuhiro; Sakamoto, Noriko; Hamada, Shigeyuki; Tomono, Kazunori

    2017-03-24

    Identification of carbapenemase-producing Enterobacteriaceae (CPE) in faecal specimens is challenging. This fact is particularly critical because low-level carbapenem-resistant organisms such as IMP-producing CPE are most prevalent in Japan. We developed a modified selective medium more suitable for IMP-type CPE. Fifteen reference CPE strains producing different types of β-lactamases were used to evaluate the commercially available CHROMagar KPC and chromID CARBA as well as the newly prepared MC-ECC medium (CHROMagar ECC supplemented with meropenem, cloxacillin, and ZnSO 4 ) and M-ECC medium (CHROMagar ECC supplemented with meropenem and ZnSO 4 ). A total of 1035 clinical samples were then examined to detect CPE using chromID CARBA and M-ECC medium. All tested strains producing NDM-, KPC-, and OXA-48-carbapenemases were successfully cultured in the media employed. Although most of the IMP-positive strains did not grow in CHROMagar KPC, chromID CARBA, or MC-ECC, all tested strains grew on M-ECC. When faecal samples were applied to the media, M-ECC medium allowed the best growth of IMP-type CPE with a significantly higher sensitivity (99.3%) than that of chromID CARBA (13.9%). M-ECC medium was determined as the most favourable selective medium for the detection of IMP-type CPE as well as other types of CPE.

  12. High-efficiency free-electron laser results

    International Nuclear Information System (INIS)

    Boyer, K.; Baru, C.A.; Newnam, B.E.; Stein, W.E.; Warren, R.W.; Winston, J.G.; Young, L.M.

    1983-01-01

    Results obtained with a tapered-wiggler free-electron laser demonstrate the concepts proposed by Morton for enhanced efficiency and show deceleration of electrons by as much as 7%, and extraction of more than 3% of the total electron-beam energy as laser energy when the laser is operated as an amplifier. The experiment is presently being reconfigured to examine its performance as a laser oscillator

  13. IMP-27, a Unique Metallo-β-Lactamase Identified in Geographically Distinct Isolates of Proteus mirabilis.

    Science.gov (United States)

    Dixon, Nyssa; Fowler, Randal C; Yoshizumi, A; Horiyama, Tsukasa; Ishii, Y; Harrison, Lucas; Geyer, Chelsie N; Moland, Ellen Smith; Thomson, Kenneth; Hanson, Nancy D

    2016-10-01

    A novel metallo-β-lactamase gene, blaIMP-27, was identified in unrelated Proteus mirabilis isolates from two geographically distinct locations in the United States. Both isolates harbor blaIMP-27 as part of the first gene cassette in a class 2 integron. Antimicrobial susceptibility testing indicated susceptibility to aztreonam, piperacillin-tazobactam, and ceftazidime but resistance to ertapenem. However, hydrolysis assays indicated that ceftazidime was a substrate for IMP-27. Copyright © 2016 Dixon et al.

  14. NASA-DoD Lead-Free Electronics Project

    Science.gov (United States)

    Kessel, Kurt

    2010-01-01

    This slide presentation reviews the current state of the lead-free electronics project. It characterizes the test articles, which were built with lead-free solder and lead-free component finishes. The tests performed and reported on are: thermal cycling, combine environments testing, mechanical shock testing, vibration testing and drop testing.

  15. Evaluation of newborns with brain disease using 123I-IMP SPECT

    International Nuclear Information System (INIS)

    Oshima, Motoo; Yasukochi, Hiroshi; Suzuki, Chizuko; Sasaki, Junko; Kitoh, Osamu.

    1993-01-01

    Eleven newborns with suspected cerebral disease were evaluated using 123 I-IMP SPECT. In a normal subject, high uptake was shown in the sensorimotor cortex, thalamus, midbrain-brainstem, and cerebellar vermis. Decreased perfusion was also noted in the frontal lobe. In hypoxic ischemic encephalopathy (HIE), diffuse decreased uptake which showed no redistribution in the white matter was seen in two patients. These two patients had a poor prognosis. In one of the other 4 patients with HIE, persistent defect in parasagittal area was recognized and the patient also had a poor prognosis. In one of two patients with tuberous sclerosis, 123 I-IMP SPECT showed high uptake in the area of increased density shown in CT. Thus, 123 I-IMP SPECT of newborn has characteristic findings different from the adult. This tracer also might have a prognostic value of clinical improvement following HIE. (author)

  16. I-123 IMP brain scintigraphies in asphyxiated newborns

    International Nuclear Information System (INIS)

    Maeda, Hisatoshi; Konishi, Yukuo; Kuriyama, Masanori; Ishii, Yasushi; Sudo, Masakatsu

    1987-01-01

    Brain scintigraphies with N-Isopropyl (I-123) p-Iodoamphetamine (I-123 IMP) were conducted in eight patients who had asphyxia at the time of birth. Two patients, 15 and 26 year-old, had local defects and diffuse low cerebral uptakes. Two children, 70 day and 2 year-old, had no cerebral uptake. Brain scintigraphies were carried out twice in three among four newborns. Only slight I-123 IMP brain uptakes were observed in the first 10 days. The lateral views of the brain scintigraphies showed increased uptake in the middle region of the brain between 10 to 30 days and reached almost equally distributed in frontal, middle and posterior regions after 30 days. These results were thought to represent rather developmental changes of the cerebral blood flow after ischemic attacks at birth. (author)

  17. mTOR complex 2 phosphorylates IMP1 cotranslationally to promote IGF2 production and the proliferation of mouse embryonic fibroblasts

    DEFF Research Database (Denmark)

    Dai, Ning; Christiansen, Jan; Nielsen, Finn

    2013-01-01

    uncover a new mechanism by which mTOR regulates organismal growth by promoting IGF2 production in the mouse embryo through mTORC2-catalyzed cotranslational IMP1/IMP3 phosphorylation. Inasmuch as TORC2 is activated by association with ribosomes, the present results indicate that mTORC2-catalyzed...... production, and diminished proliferation. The proliferation of the IMP1-null fibroblasts can be restored to wild-type levels by IGF2 in vitro or by re-expression of IMP1, which corrects the defects in IGF2 RNA splicing and translation. The ability of IMP1 to correct these defects is dependent on IMP1...

  18. IMP2, a nuclear gene controlling the mitochondrial dependence of galactose, maltose and raffinose utilization in Saccharomyces cerevisiae.

    Science.gov (United States)

    Donnini, C; Lodi, T; Ferrero, I; Puglisi, P P

    1992-02-01

    The IMP2 gene of Saccharomyces cerevisiae is involved in the nucleo-mitochondrial control of maltose, galactose and raffinose utilization as shown by the inability of imp2 mutants to grow on these carbon sources in respiratory-deficient conditions or in the presence of ethidium bromide and erythromycin. The negative phenotype cannot be scored in the presence of inhibitors of respiration and oxidative phosphorylation, indicating that the role of the mitochondria in the utilization of the above-mentioned carbon sources in imp2 mutants is not at the energetical level. Mutations in the IMP2 gene also confer many phenotypic alterations in respiratory-sufficient conditions, e.g. leaky phenotype on oxidizable carbon sources, sensitivity to heat shock and sporulation deficiency. The IMP2 gene has been cloned, sequenced and disrupted. The phenotype of null imp2 mutants is indistinguishable from that of the originally isolated mutant.

  19. Free-electron lasers 2

    International Nuclear Information System (INIS)

    Petroff, Y.

    1989-01-01

    This book presents papers on free-electron laser technology. The authors cover technological developments on existing FELs, new FEL research, and the use of FELs in experimental investigations. Among the studies reported are lasing in the visible and UV on the Novosibirsk VEPP-3 storage ring, description of Japanese FEL research, and Mark III FEL, and the Paladin results

  20. A Preliminary Version of Heavy Ion Treatment Planning System at IMP

    International Nuclear Information System (INIS)

    Liu Xinguo; Dai Zhongying; Ye Fei; Wu Qingfeng; Li Ping; Li Qiang; Jin Xiaodong; Du Xiaogang; WangYangping; Dang Jianwu

    2010-01-01

    Based on the Heavy Ion Research Facility in Lanzhou (HIRFL/HIRFL-CSR), clinical trials of heavy ion radiotherapy are being conducted at the Institute of Modern Physics (IMP), Chinese Academy of Sciences, where two-dimensional(2D) layer-stacking conformal irradiation method in a passive beam delivery system was applied. To make better use of the biophysical advantages of heavy ion beams and ensure success of the clinical trials, a preliminary version of heavy ion treatment planning system (TPS) has been developed at IMP. The TPS was designed in a manner to adapt to the 2D layer-stacking conformal irradiation method. The architecture and function of the TPS software and the implementation of dose calculation algorithm in the TPS were introduced in this paper.The deviation between the doses planned by the TPS and measured through an anthropomorphous phantom was verified to be less than 5%. Finally,the pending issues for developing a sophisticated treatment planning system at IMP were discussed. (authors)

  1. Linac-driven XUV free-electron laser

    International Nuclear Information System (INIS)

    Newnam, B.E.; Goldstein, J.C.; Fraser, J.S.; Cooper, R.K.

    1983-01-01

    Use of an rf linear accelerator as the electron source for a free-electron laser operating in the extreme ultraviolet wavelength range from 100 nm to at least as low as 50 nm appears feasible. Peak and average power outputs of greater than 100 kW and 50W, respectively, are predicted

  2. Rapid Control Prototyping Plataform for Didactic Plant Motor DC

    Directory of Open Access Journals (Sweden)

    Cristian Bazán-Orobio

    2013-06-01

    Full Text Available In this paper a design, implementation and validation of a Rapid Control Prototype platform for a plant based on a DC motor is proposed. This low-cost prototype provides of an electronic card (with a motor DC and sensors manipulated by PC with free software tools using Linux, Scilab / Scicos and RTAI-Lab. This RCP System allows developing speed -position control trainings by using different types of PID industrial controllers with anti – wind up and bump less transfer schemes. We develop a speed control application structured in four steps: identification, controller design, simulation and real time control, where there are pedagogical advantages of a platform that not only allows simulation but also real-time control of a plant.

  3. Electron beam requirements for soft x-ray/XUV free-electron lasers

    International Nuclear Information System (INIS)

    Goldstein, J.C.

    1987-01-01

    A discussion of the electron beam quality (peak current, energy spread, and transverse emittance) required to drive short wavelength free-electron lasers in the XUV (10-100 nm) and soft x-ray (<10 nm) optical wavelength ranges is presented

  4. Streaming energetic electrons in earth's magnetotail - Evidence for substorm-associated magnetic reconnection

    Science.gov (United States)

    Bieber, J. W.; Stone, E. C.

    1980-01-01

    This letter reports the results of a systematic study of streaming greater than 200 keV electrons observed in the magnetotail with the Caltech Electron/Isotope Spectrometers aboard IMP-7 and IMP-8. A clear statistical association of streaming events with southward magnetic fields, often of steep inclination, and with substorms as evidenced by the AE index is demonstrated. These results support the interpretation that streaming energetic electrons are indicative of substorm-associated magnetic reconnection in the near-earth plasma sheet.

  5. Clinical research on quantitative imaging of cerebral blood flow using 123I-IMP

    International Nuclear Information System (INIS)

    Kinoshita, Hirofumi

    1987-01-01

    Cerebral blood flow measurement was performed using N-Isopropyl-p-( 123 I)-Iodoam-phetamine (IMP) and rotating gammacamera emission computed tomography (ECT), and a new quantitative profile curve was designed. There was a good correlation between the cerebral blood flow measured by intravenous Xe-133 method and that measured by IMP method in ten normal volunteers. IMP-ECT was performed in 40 patients with various cerebral diseases. The following results were obtained: 1. Minimum recognizable cerebral blood flow difference was 5 ml/100 g/min. 2. Quantitative redistribution was observed in approximately half of the cases which showed qualitative redistribution. 3. The incidence of crossed cerebellar diaschiasis was high among patients with significant cerebral disease (8 cases/10 cases). (author)

  6. Incorporation of a recombinant Eimeria maxima IMP1 antigen into nanoparticles confers protective immunity against E. Maxima challenge infection.

    Science.gov (United States)

    Jenkins, Mark C; Stevens, Laura; O'Brien, Celia; Parker, Carolyn; Miska, Katrzyna; Konjufca, Vjollca

    2018-02-14

    The purpose of this study was to determine if conjugating a recombinant Eimeria maxima protein, namely EmaxIMP1, into 20 nm polystyrene nanoparticles (NP) could improve the level of protective immunity against E. maxima challenge infection. Recombinant EmaxIMP1 was expressed in Escherichia coli as a poly-His fusion protein, purified by NiNTA chromatography, and conjugated to 20 nm polystyrene NP (NP-EmaxIMP1). NP-EMaxIMP1 or control non-recombinant (NP-NR) protein were delivered per os to newly-hatched broiler chicks with subsequent booster immunizations at 3 and 21 days of age. In battery cage studies (n = 4), chickens immunized with NP-EMaxIMP1 displayed complete protection as measured by weight gain (WG) against E. maxima challenge compared to chickens immunized with NP-NR. WG in the NP-EMaxIMP1-immunized groups was identical to WG in chickens that were not infected with E. maxima infected chickens. In floor pen studies (n = 2), chickens immunized with NP-EMaxIMP1 displayed partial protection as measured by WG against E. maxima challenge compared to chickens immunized with NP-NR. In order to understand the basis for immune stimulation, newly-hatched chicks were inoculated per os with NP-EMaxIMP1 or NP-NR protein, and the small intestine, bursa, and spleen, were examined for NP localization at 1 h and 6 h post-inoculation. Within 1 h, both NP-EMaxIMP1 and NP-NR were observed in all 3 tissues. An increase was observed in the level of NP-EmaxIMP1 and NP-NR in all tissues at 6 h post-inoculation. These data indicate that 20 nm NP-EmaxIMP1 or NP-NR reached deeper tissues within hours of oral inoculation and elicited complete to partial immunity against E. maxima challenge infection. Published by Elsevier Ltd.

  7. Rippled beam free electron laser amplifier

    Science.gov (United States)

    Carlsten, Bruce E.

    1999-01-01

    A free electron laser amplifier provides a scalloping annular electron beam that interacts with the axial electric field of a TM.sub.0n mode. A waveguide defines an axial centerline and, a solenoid arranged about the waveguide produces an axial constant magnetic field within the waveguide. An electron beam source outputs a annular electron beam that interacts with the axial magnetic field to have an equilibrium radius and a ripple radius component having a variable radius with a ripple period along the axial centerline. An rf source outputs an axial electric field that propagates within the waveguide coaxial with the electron beam and has a radial mode that interacts at the electron beam at the equilibrium radius component of the electron beam.

  8. Beam conditioner for free electron lasers and synchrotrons

    International Nuclear Information System (INIS)

    Liu, H.; Neil, G.R.

    1998-01-01

    A focused optical has been used to introduce an optical pulse, or electromagnetic wave, collinear with the electron beam in a free electron laser or synchrotron thereby adding an axial field component that accelerates the electrons on the radial outside of the distribution of electrons in the electron beam. This invention consists of using the axial electrical component of a TEM 10 mode Gaussian beam in vacuum to condition the electron beam and speed up the outer electrons in the beam. The conditioning beam should possess about the same diameter as the electron beam. The beam waist of the conditioning wave must be located around the entrance of the undulator longitudinally to have a net energy exchange between the electrons in the outer part of the distribution and the conditioning wave owing to the natural divergence of a Gaussian beam. By accelerating the outer electrons, the outer and core electrons are caused to stay in phase. This increases the fraction of the electron beam energy that is converted to light thereby improving the efficiency of conversion of energy to light and therefore boosting the power output of the free electron laser and synchrotron. 4 figs

  9. Study on uptake and dynamics of [sup 123]I-IMP in pulmonary diseases

    Energy Technology Data Exchange (ETDEWEB)

    Taguchi, Masato (Kagoshima Univ. (Japan). Faculty of Medicine)

    1992-11-01

    The aim of this study was to assess serial uptake of N-isopropyl-p-[I-123] iodoamphetamine (I-123 IMP) quantitatively in the lung. A total of 53 patients were enrolled in the study, consisting of 34 with lung cancer, 12 with inflammatory disease and 7 with miscellaneous diseases. The findings were compared with those with [sup 99m]Tc-MAA. The 1- or 2-min I-123 IMP images were analogous to those of [sup 99m]Tc-MAA in 24 patients. Early I-132 IMP images seemed to be governed by pulmonary arterial blood flow. I-123 IMP was not taken up by cancerous lesions of the lung on both 30 min and 4 hr images. Nor was it taken up by other malignancy. It was taken up by all inflammatory lesions, including pneumonia and infiltrate surrounding lung abscess. Collapse lesions were shown as warm or cold areas on 30 min images and as hot spots on 4 hr images. IMP was not taken up by pleural effusions. Pulmonary arterial blood flow was shown as cold areas at 30 min, and as warm or cold areas at 4 hr. In conclusion, intrathoracic cancerous lesions, cavities and pleural effusions were shown as cold areas on both early and delayed images. Both inflammatory and collapse lesions were shown as hot areas on delayed images. Quantitative assessment of the lesion/contralateral lung count ratios suggested different mechanism in tracer uptake: delayed clearance and delayed fill-in may be involved in the mechanism for inflammation and collapse, respectively. (N.K.).

  10. Workshop on scientific and industrial applications of free electron lasers

    International Nuclear Information System (INIS)

    Difilippo, F.C.; Perez, R.B.

    1990-05-01

    A Workshop on Scientific and Industrial Applications of Free Electron Lasers was organized to address potential uses of a Free Electron Laser in the infrared wavelength region. A total of 13 speakers from national laboratories, universities, and the industry gave seminars to an average audience of 30 persons during June 12 and 13, 1989. The areas covered were: Free Electron Laser Technology, Chemistry and Surface Science, Atomic and Molecular Physics, Condensed Matter, and Biomedical Applications, Optical Damage, and Optoelectronics

  11. Evaluation of newborns with brain disease using [sup 123]I-IMP SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Oshima, Motoo; Yasukochi, Hiroshi (Teikyo Univ., Tokyo (Japan). Faculty of Medicine); Suzuki, Chizuko; Sasaki, Junko; Kitoh, Osamu

    1993-07-01

    Eleven newborns with suspected cerebral disease were evaluated using [sup 123]I-IMP SPECT. In a normal subject, high uptake was shown in the sensorimotor cortex, thalamus, midbrain-brainstem, and cerebellar vermis. Decreased perfusion was also noted in the frontal lobe. In hypoxic ischemic encephalopathy (HIE), diffuse decreased uptake which showed no redistribution in the white matter was seen in two patients. These two patients had a poor prognosis. In one of the other 4 patients with HIE, persistent defect in parasagittal area was recognized and the patient also had a poor prognosis. In one of two patients with tuberous sclerosis, [sup 123]I-IMP SPECT showed high uptake in the area of increased density shown in CT. Thus, [sup 123]I-IMP SPECT of newborn has characteristic findings different from the adult. This tracer also might have a prognostic value of clinical improvement following HIE. (author).

  12. Operation of a Fast-RICH Prototype with VLSI readout electronics

    Energy Technology Data Exchange (ETDEWEB)

    Guyonnet, J.L. (CRN, IN2P3-CNRS / Louis Pasteur Univ., Strasbourg (France)); Arnold, R. (CRN, IN2P3-CNRS / Louis Pasteur Univ., Strasbourg (France)); Jobez, J.P. (Coll. de France, 75 - Paris (France)); Seguinot, J. (Coll. de France, 75 - Paris (France)); Ypsilantis, T. (Coll. de France, 75 - Paris (France)); Chesi, E. (CERN / ECP Div., Geneve (Switzerland)); Racz, A. (CERN / ECP Div., Geneve (Switzerland)); Egger, J. (Paul Scherrer Inst., Villigen (Switzerland)); Gabathuler, K. (Paul Scherrer Inst., Villigen (Switzerland)); Joram, C. (Karlsruhe Univ. (Germany)); Adachi, I. (KEK, Tsukuba (Japan)); Enomoto, R. (KEK, Tsukuba (Japan)); Sumiyoshi, T. (KEK, Tsukuba (Japan))

    1994-04-01

    We discuss the first test results, obtained with cosmic rays, of a full-scale Fast-RICH Prototype with proximity-focused 10 mm thick LiF (CaF[sub 2]) solid radiators, TEA as photosensor in CH[sub 4], and readout of 12 x 10[sup 3] cathode pads (5.334 x 6.604 mm[sup 2]) using dedicated VLSI electronics we have developed. The number of detected photoelectrons is 7.7 (6.9) for the CaF[sub 2] (LiF) radiator, very near to the expected values 6.4 (7.5) from Monte Carlo simulations. The single-photon Cherenkov angle resolution [sigma][sub [theta

  13. Digital Distribution of Advertising for Publications (DDAP): a graphic arts prototype of electronic intermedia publishing (EIP)

    Science.gov (United States)

    Dunn, Patrice M.

    1998-01-01

    The Digital Distribution of Advertising for Publications (DDAP) is a graphic arts industry prototype of Electronic Intermedia Publishing (EIP). EIP is a strategic, multi- industrial concept that seeks to enable the capture and input of volumes of data (i.e., both raster and object oriented data -- as well as the latter's antecedent which is vector data -- color data and black-and-white data) from a multiplicity of devices; then flowing, controlling, manipulating, modifying, storing, retrieving, transmitting, and shipping, that data through an industrial process for output to a multiplicity of output devices (e.g., ink on paper, toner on paper, bits and bytes on CD ROM, Internet, Multimedia, HDTV, etc.). As the technical requirements of the print medium are among the most rigorous in the Intermedia milieu the DDAP prototype addresses some of the most challenging issues faced in Electronic Intermedia Publishing (EIP).

  14. Spontaneous emission and gain in a waveguide free-electron laser

    International Nuclear Information System (INIS)

    Golightly, W.J.; Ride, S.K.

    1991-01-01

    A free-electron laser enclosed in a waveguide of narrowly spaced parallel plates has been proposed as a compact, coherent source of far-infrared radiation. In this paper, the spontaneous emission and small-signal gain of such a device are analyzed. Maxwell's equations are solved for the fields of a relativistic electron beam passing through a linearly polarized undulator in the presence of a parallel-plane waveguide. The radiation intensity is resolved into its component waveguide modes for the fundamental frequency and for all harmonics. The intensity profile in a given harmonic mode is altered significantly when a parameter involving the undulator period, beam energy, and transverse dimension of the guide is such that the radiation group velocity is close to the electrons' axial velocity. The small-signal gain in the waveguide free-electron laser is calculated and related to the spontaneous emission. Near zero slip, the gain curve is significantly different from that of a free-space free-electron laser with the same parameters

  15. Response of the CALICE Si-W Electromagnetic Calorimeter Physics Prototype to Electrons

    CERN Document Server

    Adloff, C.; Repond, J.; Yu, J.; Eigen, G.; Hawkes, C.M.; Mikami, Y.; Miller, O.; Watson, N.K.; Wilson, J.A.; Goto, T.; Mavromanolakis, G.; Thomson, M.A.; Ward, D.R.; Yan, W.; Benchekroun, D.; Hoummada, A.; Krim, M.; Benyamna, M.; Boumediene, D.; Brun, N.; Carloganu, C.; Gay, P.; Morisseau, F.; Blazey, G.C.; Chakraborty, D.; Dyshkant, A.; Francis, K.; Hedin, D.; Lima, G.; Zutshi, V.; Hostachy, J.-Y.; Morin, L.; D'Ascenzo, N.; Cornett, U.; David, D.; Fabbri, R.; Falley, G.; Gadow, K.; Garutti, E.; Gottlicher, P.; Jung, T.; Karstensen, S.; Korbel, V.; Lucaci-Timoce, A.-I.; Lutz, B.; Meyer, N.; Morgunov, V.; Reinecke, M.; Sefkow, F.; Smirnov, P.; Vargas-Trevino, A.; Wattimena, N.; Wendt, O.; Feege, N.; Groll, M.; Haller, J.; Heuer, R.-D.; Richter, S.; Samson, J.; Kaplan, A.; Schultz-Coulon, H.-Ch.; Shen, W.; Tadday, A.; Bilki, B.; Norbeck, E.; Onel, Y.; Kim, E.J.; Baek, N.I.; Kim, D-W.; Lee, K.; Lee, S.C.; Kawagoe, K.; Tamura, Y.; Bowerman, D.A.; Dauncey, P.D.; Magnan, A.-M.; Yilmaz, H.; Zorba, O.; Bartsch, V.; Postranecky, M.; Warren, M.; Wing, M.; Faucci Giannelli, M.; Green, M.G.; Salvatore, F.; Bedjidian, M.; Kieffer, R.; Laktineh, I.; Bailey, D.S.; Barlow, R.J.; Kelly, M.; Thompson, R.J.; Danilov, M.; Tarkovsky, E.; Baranova, N.; Karmanov, D.; Korolev, M.; Merkin, M.; Voronin, A.; Frey, A.; Lu, S.; Prothmann, K.; Simon, F.; Bouquet, B.; Callier, S.; Cornebise, P.; Fleury, J.; Li, H.; Richard, F.; de la Taille, Ch.; Poeschl, R.; Raux, L.; Ruan, M.; Seguin-Moreau, N.; Wicek, F.; Anduze, M.; Boudry, V.; Brient, J-C.; Gaycken, G.; Mora de Freitas, P.; Musat, G.; Reinhard, M.; Rouge, A.; Vanel, J-Ch.; Videau, H.; Park, K-H.; Zacek, J.; Cvach, J.; Gallus, P.; Havranek, M.; Janata, M.; Marcisovsky, M.; Polak, I.; Popule, J.; Tomasek, L.; Tomasek, M.; Ruzicka, P.; Sicho, P.; Smolik, J.; Vrba, V.; Zalesak, J.; Belhorma, B.; Belmir, M.; Nam, S.W.; Park, I.H.; Yang, J.; Chai, J.-S.; Kim, J.-T.; Kim, G.-B.; Kang, J.; Kwon, Y.-J.

    2009-01-01

    A prototype Silicon-Tungsten electromagnetic calorimeter (ECAL) for an International Linear Collider (ILC) detector was installed and tested during summer and autumn 2006 at CERN. The detector had 6480 silicon pads of dimension 1x1 cm^2. Data were collected with electron beams in the energy range 6 to 45 GeV. The analysis described in this paper focuses on electromagnetic shower reconstruction and characterises the ECAL response to electrons in terms of energy resolution and linearity. The detector is linear to within approximately the 1% level and has a relative energy resolution of (16.6 +- 0.1)/ \\sqrt{E(GeV}) + 1.1 +- 0.1 (%). The spatial uniformity and the time stability of the ECAL are also addressed.

  16. A spectral unaveraged algorithm for free electron laser simulations

    International Nuclear Information System (INIS)

    Andriyash, I.A.; Lehe, R.; Malka, V.

    2015-01-01

    We propose and discuss a numerical method to model electromagnetic emission from the oscillating relativistic charged particles and its coherent amplification. The developed technique is well suited for free electron laser simulations, but it may also be useful for a wider range of physical problems involving resonant field–particles interactions. The algorithm integrates the unaveraged coupled equations for the particles and the electromagnetic fields in a discrete spectral domain. Using this algorithm, it is possible to perform full three-dimensional or axisymmetric simulations of short-wavelength amplification. In this paper we describe the method, its implementation, and we present examples of free electron laser simulations comparing the results with the ones provided by commonly known free electron laser codes

  17. Free Electron Lasers in 2005

    CERN Document Server

    Colson, W B; Voughs, T

    2005-01-01

    Twenty-eight years after the first operation of the short wavelength free electron laser (FEL) at Stanford University, there continue to be many important experiments, proposed experiments, and user facilities around the world. Properties of FELs in the infrared, visible, UV, and x-ray wavelength regimes are listed and discussed.

  18. Free Electron Lasers in 2004

    CERN Document Server

    Colson, William B

    2004-01-01

    Twenty-seven years after the first operation of the short wavelength free electron laser (FEL) at Stanford University, there continue to be many important experiments, proposed experiments, and user facilities around the world. Properties of FELs operating in the infrared, visible, UV, and x-ray wavelength regimes are listed and discussed.

  19. Free-Free Transitions in the Presence of Laser Fields at Very Low Incident Electron Energy

    Science.gov (United States)

    Bhatia, A. K.; Sinha, Chandana

    2010-01-01

    We study the free-free transition in electron-hydrogenic systems in ground state in presence of an external laser field at very loud incident energies. The laser field is treated classically while the collision dynamics is treated quantum mechanically. The laser field is chosen to be monochromatic, linearly polarized and homogeneous. The incident electron is considered to be dressed by the laser in a nonperturbative manner by choosing a Volkov wave function for it. The scattering weave function for the electron is solved numerically by taking into account the effect of the electron exchange, short-range as well as of the long-range interactions to get the S and P wave phase shifts while for the higher angular momentum phase shifts the exchange approximation has only been considered. We calculate the laser assisted differential cross sections (LADCS) for the aforesaid free-free transition process for single photon absorption/emission. The laser intensity is chosen to be much less than the atomic field intensity. A strong suppression is noted in the LADCS as compared to the field free (FF) cross sections. Unlike the FF ones, the LADCS exhibit some oscillations having a distinct maximum at a low value of the scattering angle depending on the laser parameters as well as on the incident energies.

  20. Free-electron laser beam

    International Nuclear Information System (INIS)

    Minehara, Eisuke

    2003-01-01

    The principle and history of free-electron laser (FEL), first evidenced in 1977, the relationship between FEL wavelength and output power, the high-power FEL driven by the superconducting linac, the X-ray FEL by the linac, and the medical use are described. FEL is the vacuum oscillator tube and essentially composed from the high-energy linac, undulator and light-resonator. It utilizes free electrons in the vacuum to generate the beam with wavelength ranging from microwave to gamma ray. The first high-power FEL developed in Japanese Atomic Energy Research Institute (JAERI) is based on the development of superconducting linac for oscillating the highest power beam. In the medical field, applications to excise brain tumors (in US) and to reconstruct experimentally blood vessels in the pig heart (in Gunma University) by lasing and laser coagulator are in progress with examinations to remove intra-vascular cholesterol mass by irradiation of 5.7μm FEL beam. Cancer cells are considered diagnosed by FEL beam of far-infrared-THz range. The FEL beam CT is expected to have a wide variety of application without the radiation exposure and its resolution is equal or superior to that of usual imaging techniques. (N.I.)

  1. Preliminary experiments on a planar electron beam for an intense free electron maser

    International Nuclear Information System (INIS)

    Kato, Katsumasa; Iwata, Kazuma; Kitamura, Taro; Yamada, Naohisa; Soga, Yukihiro; Kamada, Keiichi; Yoshida, Mitsuhiro; Ginzburg, Naum S.

    2013-01-01

    A planar wiggler magnetic field was used to increase the output power of an intense free electron maser. As a preliminary experiment, a cylindrical electron beam was injected into a planar wiggler field with an axial magnetic field. Without the axial magnetic field, the cylindrical beam could not propagate through the wiggler field with length of 1 m. The microwave with frequency of 40 GHz was observed only when the beam propagates through the wiggler field. The frequency was nearly equal to the expected frequency of the free electron maser interaction. Though a sheet electron beam with nearly the same energy propagated through the planar wiggler field with deformation of its cross section, the microwave with frequency of 40 GHz was not observed. (author)

  2. The study of the lung accumulation of I-123 IMP by the broncho-alveolar lavage

    International Nuclear Information System (INIS)

    Itasaka, Miyoko; Ikeda, Hideki; Yakuwa, Naoshi; Kato, Shuichi; Takahashi, Keiji; Yasui, Shoji

    1989-01-01

    We studied the accumulated portion and the movement of I-123 IMP in the lung. Ten subjects were studied. They were four patients with fibrosing lung disease, two with lung cancer, and four with other lung disease. They underwent the broncho-alveolar lavage (BAL) for the diagnosis of their diseases. l.5 mCi of I-123 IMP was injected into the ante-cubital vein. The BAL examination was carried out about 40 minutes after the injection of I-123 IMP. The subjects' blood was sampled at the same time. The total BAL liquid (BAL-T) was divided into the fluid component (BAL-F) and the cell component (BAL-C) by centrifugation. The radioactivities in BAL-T, BAL-F, BAL-C, and serum (B-S) were measured by the well-counter. The average of BAL-T/B-S, BAL-F/B-S and BAL-C/B-S were 6.86, 4.26 and 2.71 respectively. It was confirmed that I-123 IMP was transported from the pulmonary capillary to the alveolar space and was taken up by the alveolar cells. It was considered that the analysis of the I-123 IMP release from the lung showed not only the endothelial cell uptake function but also the interstitial and material cells' amine transport and uptake function. (author)

  3. Acceleration of electrons using an inverse free electron laser auto- accelerator

    International Nuclear Information System (INIS)

    Wernick, I.K.; Marshall, T.C.

    1992-07-01

    We present data from our study of a device known as the inverse free electron laser. First, numerical simulations were performed to optimize the design parameters for an experiment that accelerates electrons in the presence of an undulator by stimulated absorption of radiation. The Columbia free electron laser (FEL) was configured as an auto-accelerator (IFELA) system; high power (MW's) FEL radiation at ∼1.65 mm is developed along the first section of an undulator inside a quasi-optical resonator. The electron beam then traverses a second section of undulator where a fraction of the electrons is accelerated by stimulated absorption of the 1.65 mm wavelength power developed in the first undulator section. The second undulator section has very low gain and does not generate power on its own. We have found that as much as 60% of the power generated in the first section can be absorbed in the second section, providing that the initial electron energy is chosen correctly with respect to the parameters chosen for the first and second undulators. An electron momentum spectrometer is used to monitor the distribution of electron energies as the electrons exit the IFELA. We have found; using our experimental parameters, that roughly 10% of the electrons are accelerated to energies as high as 1100 keV, in accordance with predictions from the numerical model. The appearance of high energy electrons is correlated with the abrupt absorption of millimeter power. The autoaccelerator configuration is used because there is no intense source of coherent power at the 1.65 mm design wavelength other than the FEL

  4. Shack-Hartmann Electron Densitometer (SHED): An Optical System for Diagnosing Free Electron Density in Laser-Produced Plasmas

    Science.gov (United States)

    2016-11-01

    Free Electron Density in Laser-Produced Plasmas by Anthony R Valenzuela Approved for public release; distribution is...AND SUBTITLE Shack-Hartmann Electron Densitometer (SHED): An Optical System for Diagnosing Free Electron Density in Laser-Produced Plasmas 5a...SUPPLEMENTARY NOTES 14. ABSTRACT The Shack-Hartmann Electron Densitometer is a novel method to diagnose ultrashort pulse laser–produced plasmas

  5. A Prototype User Interface for a Mobile Electronic Clinical Note Data Entry System

    OpenAIRE

    Zafar, Atif; Lehto, Mark; Kim, Jongseo

    2005-01-01

    Recent advances in mobile computing technologies have made electronic medical records (EMRs) on handheld devices an attractive possibility. However, data entry paradigms popular on desktop machines do not translate well to mobile devices1,2. Based on a review of the literature on mobile device usability1–4, we built a prototype user interface for mobile EMRs and held focus groups with clinician users whose feedback provided useful insight about design choices, functionality and...

  6. Fully Atomistic Understanding of the Electronic and Optical Properties of a Prototypical Doped Charge-Transfer Interface

    DEFF Research Database (Denmark)

    Brivio, Gian Paolo; Baby, Anu; Gruenewald, Marco

    2017-01-01

    The current study generates profound atomistic insights into doping-induced changes of the optical and electronic properties of the prototypical PTCDA/Ag(111) interface. For doping K atoms are used, as KxPTCDA/Ag(111) has the distinct advantage of forming well-defined stoichiometric phases...

  7. PCM-air heat exchangers for free-cooling applications in buildings: Experimental results of two real-scale prototypes

    International Nuclear Information System (INIS)

    Lazaro, Ana; Dolado, Pablo; Marin, Jose M.; Zalba, Belen

    2009-01-01

    Latent heat storage using phase change materials (PCM) can be used for free-cooling. In this application low air temperature is used to solidify the PCM during the night and then during the next day, the inside air of a building can be cooled down by exchanging heat with PCM. Short times for charging and discharging the PCM are required. PCM have in general low thermal conductivity, therefore the heat exchanger design is very important to fulfil free-cooling requirements. This paper presents an experimental setup for testing PCM-air real-scale heat exchangers and the results for two real-scale prototypes. Results show that a heat exchanger using a PCM with lower thermal conductivity and lower total stored energy, but adequately designed, has higher cooling power and can be applied for free-cooling

  8. Regional cerebral blood flow in epileptic foci using [I-123] IMP-SPECT

    International Nuclear Information System (INIS)

    Konishi, Tohru

    1989-01-01

    Fifty-six epileptic patients, whose ages ranged from 6 months to 16 years (a mean age, 8 years and 2 months), were examined by single photon emission computed tomography (SPECT) with [I-123] N-isopropyl p-iodoamphetamine (IMP). Of these patients, 44 had partial seizures (PS) and 12 had generalized seizures (GS). SPECT revealed abnormality of regional cerebral blood flow (rCBF) in 24 PS patients (54.5%), being correlated with EEG abnormality. Among the 24 patients, 22 had a decreased rCBF and 2 others had an increased rCBF. According to the PS type, rCBF abnormality in the foci was less frequently observed for benign age-related partial epilepsy (2/9) than for the other types of partial epilepsy (22/35). Among 35 patients with the other types of partial epilepsy, SPECT showed foci in the frontal (12), central (3), parietal (4), temporal (6), and occipital (6) regions, and diffuse spike-wave or the lack of paroaxysmals (4). The EEG foci was of the left hemisphere in 12 patients, and of the right hemisphere in 18 patients. Higher incidence of rCBF abnormality was associated with the temporal, partietal, and frontal foci than with the occipital foci. There was no correlation between the incidence of rCBF abnormlaity and the frequency of seizure activities on EEG. Complex partial seizures had a tendency to be associated with rCBF abnormality. In comparing IMP uptake in evaluable 17 patients with a decreased rCBF, a mean %CBF in foci compared to that in the contralateral area was 91.9%. All of the 12 GS patients showed no focal reduction of rCBF around the cortex. Patients with tonic-clonic seizure and myoclonic seizure had almost normal IMP images. The IMP images of organic lesions were a marked reduction of rCBF. IMP-SPECT may also be suitable for evaluating the underlying organic and secondary involving disorders with epilepsy. (N.K.)

  9. Free-Free Transitions in the Presence of Laser Fields and Debye Potential at Very Low Incident Electron Energies

    Science.gov (United States)

    Bhatia, Anand

    2012-01-01

    We study the free-free transition in electron-helium ion in the ground state and embedded in a Debye potential in the presence of an external laser field at very low incident electron energies. The laser field is treated classically while the collision dynamics is treated quantum mechanically. The laser field is chosen as monochromatic, linearly polarized and homogeneous. The incident electron is considered to be dressed by the laser field in a nonperturbative manner by choosing Volkov wave function for it. The scattering wave function for the incident electron on the target embedded in a Debye potential is solved numerically by taking into account the effect of electron exchange. We calculate the laser-assisted differential and total cross sections for free-free transition for absorption/emission of a single photon or no photon exchange. The results will be presented at the conference.

  10. Free form CMOS electronics: Physically flexible and stretchable

    KAUST Repository

    Hussain, Muhammad Mustafa; Rojas, Jhonathan Prieto; Sevilla, Galo T.; Hussain, Aftab M.; Ghoneim, Mohamed T.; Hanna, Amir; Kutbee, Arwa T.; Nassar, Joanna M.; Cruz, Melvin

    2015-01-01

    Free form (physically flexible and stretchable) electronics can be used for applications which are unexplored today due to the rigid and brittle nature of the state-of-the-art electronics. Therefore, we show integration strategy to rationally design

  11. Beam test of a full-length prototype of the BESIII drift chamber with the readout electronics

    International Nuclear Information System (INIS)

    Qin, Z.H.; Chen, Y.B.; Sheng, H.Y.; Wu, L.H.; Liu, J.B.; Zhuang, B.A.; Jiang, X.S.; Zhao, Y.B.; Zhu, K.J.; Yan, Z.K.; Chen, C.; Xu, M.H.; Wang, L.; Ma, X.Y.; Tang, X.; Liu, R.G.; Jin, Y.; Zhu, Q.M.; Zhang, G.F.; Wu, Z.; Li, R.Y.; Zhao, P.P.; Dai, H.L.; Li, X.P.; Li, J.

    2007-01-01

    A full-length prototype of the BESIII drift chamber together with its readout electronics was built and a beam test was performed. Two different methods, namely 'single-threshold method' and 'double-threshold method' for timing measurement, were studied. Test results show that the BESIII drift chamber and its readout electronics can reach their design specifications. The 'double-threshold method' results in a better timing accuracy and noise suppression capabilities as compared with the 'single-threshold method'

  12. An inverse free electron laser accelerator experiment

    International Nuclear Information System (INIS)

    Wernick, I.; Marshall, T.C.

    1992-01-01

    A free electron laser was configured as an autoaccelerator to test the principle of accelerating electrons by stimulated absorption of radiation (λ = 1.65mm) by an electron beam (750kV) traversing an undulator. Radiation is produced in the first section of a constant period undulator (1 w1 = 1.43cm) and then absorbed (∼ 40%) in a second undulator, having a tapered period (1 w2 = 1.8 - 2.25cm), which results in the acceleration of a subgroup (∼ 9%) of electrons to ∼ 1MeV

  13. N-isopropyl I-123 p-iodoamphetamine (IMP) brain SPECT in Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Toshimitsu; Nishikawa, Junichi; Kosaka, Noboru; Ohtake, Tohru; Watanabe, Toshiaki; Yoshikawa, Kohki; Iio, Masahiro [Tokyo Univ. (Japan). Faculty of Medicine

    1989-09-01

    Eighteen patients with Alzheimer's disease (AD), 5 patients with Pick disease (PD), 6 patients with other types of degenerative dementia (O) and 12 age-matched normal control subjects (N) were studied using N-isopropyl p-(I-123)iodoamphetamine (I-123 IMP) with SPECT. Regional to cerebellar activity (R/CE) ratio and frontal to parietal (F/R) activity ratio were evaluated in each case. I-123 IMP-SPECT revealed focal abnormality in all cases in AD, PD, O group, while XCT and/or MRI were normal or showed cerebral atrophy without focal abnormal density or intensity. In AD group, R/CE ratio in all the regions except for bilateral Rolandic area and left primary visual cortex were significantly lower (p<0.05 or p<0.01) than that in N group, and F/P ratio were significantly higher (p<0.01) than that in P and O group. In conclusion, I-123 IMP-SPECT is useful to detect focal perfusion abnormality in dementia and may be of value in differentiating Alzheimer's disease from dementia of non-Alzheimer type. (author).

  14. N-isopropyl I-123 p-iodoamphetamine (IMP) brain SPECT in Alzheimer's disease

    International Nuclear Information System (INIS)

    Momose, Toshimitsu; Nishikawa, Junichi; Kosaka, Noboru; Ohtake, Tohru; Watanabe, Toshiaki; Yoshikawa, Kohki; Iio, Masahiro

    1989-01-01

    Eighteen patients with Alzheimer's disease (AD), 5 patients with Pick disease (PD), 6 patients with other types of degenerative dementia (O) and 12 age-matched normal control subjects (N) were studied using N-isopropyl p-[I-123]iodoamphetamine (I-123 IMP) with SPECT. Regional to cerebellar activity (R/CE) ratio and frontal to parietal (F/R) activity ratio were evaluated in each case. I-123 IMP-SPECT revealed focal abnormality in all cases in AD, PD, O group, while XCT and/or MRI were normal or showed cerebral atrophy without focal abnormal density or intensity. In AD group, R/CE ratio in all the regions except for bilateral Rolandic area and left primary visual cortex were significantly lower (p<0.05 or p<0.01) than that in N group, and F/P ratio were significantly higher (p<0.01) than that in P and O group. In conclusion, I-123 IMP-SPECT is useful to detect focal perfusion abnormality in dementia and may be of value in differentiating Alzheimer's disease from dementia of non-Alzheimer type. (author)

  15. 'Diffraction-free' optical beams in inverse free electron laser accelerators

    International Nuclear Information System (INIS)

    Cai, S.Y.; Bhattacharjee, A.; Marshall, T.C.

    1988-01-01

    'Diffraction-free' optical beams correspond to exact solutions of the wave equation in free space with the remarkable property that they propagate with negligible transverse spreading for distances much larger than the Rayleigh range. The requirement for this to occur is a large aperture. Using a 2D computer code, we find that these optical beams will also propagate with negligible diffraction even when perturbed by the electron beam in an IFEL; indeed they match well the FEL requirement for the accelerator. The numerical simulations are performed for the proposed facility at Brookhaven in which λ s =10 μm, B=1.5 T (linearly tapered l w =1.31-6.28 cm) and the optical beam power is either 8x10 11 W or 2.3x10 10 W. Approximately 70% of the electrons constituting a beam of current 5 mA or 15 A, radius 0.14 mm and initial energy of 50 MeV is accelerated at 50 MeV/m. (orig.)

  16. Tests of the MICE Electron Muon Ranger frontend electronics with a small scale prototype

    Science.gov (United States)

    Bolognini, D.; Bene, P.; Blondel, A.; Cadoux, F.; Debieux, S.; Giannini, G.; Graulich, J. S.; Lietti, D.; Masciocchi, F.; Prest, M.; Rothenfusser, K.; Vallazza, E.; Wisting, H.

    2011-08-01

    The MICE experiment is being commissioned at RAL to demonstrate the feasibility of the muon ionization cooling technique for future applications such as the Neutrino Factory and the Muon Collider. The cooling will be evaluated by measuring the emittance before and after the cooling channel with two 4 T spectrometers; to distinguish muons from the background, a multi-detector particle identification system is foreseen: three Time of Flight stations, two Cherenkov counters and a calorimetric system consisting of a pre-shower layer and a fully active scintillator detector (EMR) are used to discriminate muons from pions and electrons. EMR consists of 48 planes of triangular scintillating bars coupled to WLS fibers readout by single PMTs on one side and MAPMTs on the other; each plane sensible area is 1 m 2. This article deals with a small scale prototype of the EMR detector which has been used to test the MAPMT frontend electronics based on the MAROC ASIC; the tests with cosmic rays using both an analog mode and a digital readout mode are presented. A very preliminary study on the cross talk problem is also shown.

  17. Tests of the MICE Electron Muon Ranger frontend electronics with a small scale prototype

    Energy Technology Data Exchange (ETDEWEB)

    Bolognini, D., E-mail: davide.bolognini@gmail.com [Universita degli Studi dell' Insubria, Via Valleggio 11, 22100 Como (Italy); INFN Milano Bicocca, Piazza della Scienza 3, 20126 Milano (Italy); Bene, P.; Blondel, A.; Cadoux, F.; Debieux, S. [Universite de Geneve, Quai Ernest-Ansermet 24, 1211 Geneve (Switzerland); Giannini, G. [Universita degli Studi di Trieste, Via A.Valerio, 34127 Trieste (Italy); INFN Trieste, Padriciano 99, 34012 Trieste (Italy); Graulich, J.S. [Universite de Geneve, Quai Ernest-Ansermet 24, 1211 Geneve (Switzerland); Lietti, D. [Universita degli Studi dell' Insubria, Via Valleggio 11, 22100 Como (Italy); INFN Milano Bicocca, Piazza della Scienza 3, 20126 Milano (Italy); Masciocchi, F. [Universite de Geneve, Quai Ernest-Ansermet 24, 1211 Geneve (Switzerland); Prest, M. [Universita degli Studi dell' Insubria, Via Valleggio 11, 22100 Como (Italy); INFN Milano Bicocca, Piazza della Scienza 3, 20126 Milano (Italy); Rothenfusser, K. [Universite de Geneve, Quai Ernest-Ansermet 24, 1211 Geneve (Switzerland); Vallazza, E. [INFN Trieste, Padriciano 99, 34012 Trieste (Italy); Wisting, H. [Universite de Geneve, Quai Ernest-Ansermet 24, 1211 Geneve (Switzerland)

    2011-08-01

    The MICE experiment is being commissioned at RAL to demonstrate the feasibility of the muon ionization cooling technique for future applications such as the Neutrino Factory and the Muon Collider. The cooling will be evaluated by measuring the emittance before and after the cooling channel with two 4 T spectrometers; to distinguish muons from the background, a multi-detector particle identification system is foreseen: three Time of Flight stations, two Cherenkov counters and a calorimetric system consisting of a pre-shower layer and a fully active scintillator detector (EMR) are used to discriminate muons from pions and electrons. EMR consists of 48 planes of triangular scintillating bars coupled to WLS fibers readout by single PMTs on one side and MAPMTs on the other; each plane sensible area is 1 m{sup 2}. This article deals with a small scale prototype of the EMR detector which has been used to test the MAPMT frontend electronics based on the MAROC ASIC; the tests with cosmic rays using both an analog mode and a digital readout mode are presented. A very preliminary study on the cross talk problem is also shown.

  18. Emergence of Imipenem-Resistant Pseudomonas aeruginosa Clinical Isolates from Egypt Coharboring VIM and IMP Carbapenemases.

    Science.gov (United States)

    El-Domany, Ramadan Ahmed; Emara, Mohamed; El-Magd, Mohammed A; Moustafa, Walaa H; Abdeltwab, Nesma M

    2017-09-01

    Pseudomonas aeruginosa is an important human pathogen and the leading cause of nosocomial infections. P. aeruginosa is characterized by massive intrinsic resistance to a multiple classes of antibiotics with carbapenems being the most potent inhibitor of P. aeruginosa and considered the first choice for its treatment. Therefore, it is crucial to investigate novel mechanisms of resistance of P. aeruginosa to carbapenems for achieving successful therapy. A total of 114 P. aeruginosa isolates from two university hospitals in Egypt were recruited in this study. Antimicrobial susceptibility testing revealed that 50 isolates (43.8%) exhibited multidrug-resistant (MDR) phenotype, of them 14 isolates (12.2%) were imipenem (IPM)-resistant. Of these 14 isolates, 13 isolates (11.4%) exhibited the metallo-β-lactamase (MBL) phenotype. MBLs encoding genes, VIM and IMP, were identified by PCR. PCR results revealed that four isolates harbored the VIM gene alone, one isolate harbored IMP gene alone, and four isolates harbored both genes. The correct size of PCR products of VIM and IMP genes (390 and 188 bp, respectively) were sequenced to confirm results of PCR and to look for any possible polymorphism among MBL genes of tested isolates. Data analysis of these sequences showed 100% identity of nucleotide sequences of MBL genes among tested Egyptian patients. To our knowledge, this is the first report of IMP carbapenemase-encoding gene in Africa and the first detection of the emergence of P. aeruginosa coproducing VIM and IMP genes in Egypt.

  19. Hex Chrome Free Coatings for Electronics Overview

    Science.gov (United States)

    Kessel, Kurt

    2013-01-01

    The overall objective of the Hex Chrome Free Coatings for Electronics project is to evaluate and test pretreatment coating systems not containing hexavalent chrome in avionics and electronics housing applications. This objective will be accomplished by testing strong performing coating systems from prior NASA and DoD testing or new coating systems as determined by the stakeholders.

  20. Electron-phonon coupling in quasi free-standing graphene

    DEFF Research Database (Denmark)

    Christian Johannsen, Jens; Ulstrup, Søren; Bianchi, Marco

    2013-01-01

    Quasi free-standing monolayer graphene can be produced by intercalating species like oxygen or hydrogen between epitaxial graphene and the substrate crystal. If the graphene is indeed decoupled from the substrate, one would expect the observation of a similar electronic dispersion and many......-body effects, irrespective of the substrate and the material used to achieve the decoupling. Here we investigate the electron-phonon coupling in two different types of quasi free-standing monolayer graphene: decoupled from SiC via hydrogen intercalation and decoupled from Ir via oxygen intercalation. Both...

  1. Drift velocity of free electrons in liquid argon

    International Nuclear Information System (INIS)

    Walkowiak, W.

    2000-01-01

    A measurement of the drift velocity of free electrons in liquid argon has been performed. Free electrons have been produced by photoelectric effect using laser light in a so-called 'laser chamber'. The results on the drift velocity v d are given as a function of the electric field strength in the range 0.5 kV/cm≤|E|≤12.6 kV/cm and the temperature in the range 87 K≤T≤94 K. A global parametrization of v d (|E|,T) has been fitted to the data. A temperature dependence of the electron drift velocity is observed, with a mean value of Δv d /(ΔT v d )=(-1.72±0.08)%/K in the range of 87-94 K

  2. 123I-IMP SPECT study on patients with amnestic syndrome

    International Nuclear Information System (INIS)

    Hanyu, Haruo; Abe, Shinei; Arai, Hisayuki; Takasaki, Masaru; Suzuki, Takanari; Abe, Kimihiko; Amino, Saburo

    1992-01-01

    Regional cerebral blood flow was studied using single photon emission CT (SPECT) with 123 I-IMP to elucidate the pathophysiology of amnesia. Four patients with amnestic syndrome diagnosed by DSM-III-R criteria were investigated. SPECT images demonstrated definite hypoperfusion of the temporoparietal lobe and relative sparing of motorsensory and occipital cortices in two out of four patients. Since these abnormalities of regional cerebral blood flow have been considered to be characteristic findings in dementia of the Alzheimer type, two patients with temporoparietal hypoperfusion are suggested to manifest the early stage of dementia of the Alzheimer type. Our observations suggest that 123 I-IMP SPECT is an useful madality in the diagnosis of the early stage of dementia of the Alzheimer type, especially in patients with only memory impairment. (author)

  3. Investigation of normal pressure hydrocephalus by sup 123 I-IMP SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kamiya, Ken; Yamashita, Nobuko; Nagai, Hajime [Nagoya City Univ. (Japan). Faculty of Medicine; Mizawa, Ikuo

    1991-08-01

    We evaluated N-isopropyl-p-({sup 123}I) iodoamphetamine ({sup 123}I-IMP) single photon emission computed tomography (SPECT) as a method for identifying normal pressure hydrocephalic (NPH) patients eligible for shunting procedures. {sup 123}I-IMP SPECT scans were taken before and after cerebrospinal fluid (CSF) taps in NPH cases. Post-subarachnoid hemorrhagic (SAH) patients showed apparent frontal blood flow reduction but non-SAH cases did not. The frontal blood flow increased in comparison with the temporal flow after CSF tapping in SAH cases who benefited most from shunting. Cerebral blood flow study before and after CSF removal is a potential method for classifying NPH patients likely to benefit from the shunting operation. (author).

  4. Long range coherence in free electron lasers

    Science.gov (United States)

    Colson, W. B.

    1984-01-01

    The simple free electron laser (FEL) design uses a static, periodic, transverse magnetic field to undulate relativistic electrons traveling along its axis. This allows coupling to a co-propagating optical wave and results in bunching to produce coherent radiation. The advantages of the FEL are continuous tunability, operation at wavelengths ranging from centimeters to angstroms, and high efficiency resulting from the fact that the interaction region only contains light, relativistic electrons, and a magnetic field. Theoretical concepts and operational principles are discussed.

  5. An XUV/VUV free-electron laser oscillator

    Science.gov (United States)

    Goldstein, J. C.; Newnam, B. E.; Cooper, R. K.; Comly, J. C., Jr.

    Problems regarding the extension of free-electron laser technology from the visible and near infrared region, where such devices are currently operating, to the ultraviolet have recently been extensively discussed. It was found that significant technical problems must be overcome before free-electron lasers (FELs) can be operated in the VUV (100-200 nm) and the XUV (50-100). However, the present lack of other intense and tunable sources of coherent radiation at these wavelengths together with the intrinsic properties of FELs make the development of such devices potentially very rewarding. The properties of FELs include continuous tunability in wavelength and output in the form of a train of picosecond pulses. An investigation is conducted regarding the feasibility of an operation of a FEL in the XUV/VUV regions, taking into account a theoretical model. It is found that modest improvements in electron beam and optical mirror technologies will make the design of a FEL for operation in the 50-200-nm range of optical wavelength possible.

  6. IMP 2.0: a multi-species functional genomics portal for integration, visualization and prediction of protein functions and networks.

    Science.gov (United States)

    Wong, Aaron K; Krishnan, Arjun; Yao, Victoria; Tadych, Alicja; Troyanskaya, Olga G

    2015-07-01

    IMP (Integrative Multi-species Prediction), originally released in 2012, is an interactive web server that enables molecular biologists to interpret experimental results and to generate hypotheses in the context of a large cross-organism compendium of functional predictions and networks. The system provides biologists with a framework to analyze their candidate gene sets in the context of functional networks, expanding or refining their sets using functional relationships predicted from integrated high-throughput data. IMP 2.0 integrates updated prior knowledge and data collections from the last three years in the seven supported organisms (Homo sapiens, Mus musculus, Rattus norvegicus, Drosophila melanogaster, Danio rerio, Caenorhabditis elegans, and Saccharomyces cerevisiae) and extends function prediction coverage to include human disease. IMP identifies homologs with conserved functional roles for disease knowledge transfer, allowing biologists to analyze disease contexts and predictions across all organisms. Additionally, IMP 2.0 implements a new flexible platform for experts to generate custom hypotheses about biological processes or diseases, making sophisticated data-driven methods easily accessible to researchers. IMP does not require any registration or installation and is freely available for use at http://imp.princeton.edu. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  7. Free-electron lasers with magnetized ion-wiggler

    International Nuclear Information System (INIS)

    Mehdian, H.; Jafari, S.; Hasanbeigi, A.; Ebrahimi, F.

    2009-01-01

    Significant progress has been made using laser ionized channels to guide electron beams in the ion focus regime in a free-electron laser. Propagation of an electron beam in the ion focusing regime (IFR) allows the beam to propagate without expanding from space-charge repulsion. The ninth-degree polynomial dispersion relation for electromagnetic and space-charge waves is derived analytically by solving the electron momentum transfer and wave equations. The variation of resonant frequencies and peak growth rates with axial magnetic field strength has been demonstrated. Substantial enhancement in peak growth rate is obtained as the axial field frequency approaches the gyroresonance frequency.

  8. Free Electron Laser in Poland

    CERN Document Server

    Romaniuk, Ryszard

    2009-01-01

    The idea of building a new IVth generation of light sources of high luminosity, which use accelerators, arose in the 80ties of XXth century. Now, in a numerable synchrotron and laser laboratories in Europe, there is carried out, since a couple of years, intense applied research on free electron lasers (FEL) [17,18]. Similarly, in this country, free electron laser in Poland – POLFEL [9] is, in a design, a coherent light source of the IVth generation, characterized by very short pulses in the range of 10-100fs, of big power 0,2GW and UV wavelength of 27nm, of average power 1W, with effective high power third harmonic of 9nm. The laser consists of a linear superconducting accelerator 100m in length, undulator and experimental lines. It generates a monochromatic and coherent radiation and can be tuned from THz range via IR, visible to UV, and potentially to X-rays. The linac works in quasi-CW or real-CW mode. It is planned by IPJ [9,10] and XFEL-Poland Consortium [16] as a part of the ESFRI [1] priority EuroFEL...

  9. Search for electron decay mode e- → γ + νe with prototype of Borexino detector

    International Nuclear Information System (INIS)

    Back, H.O.; Balata, M.; Bari, A. de.

    2002-01-01

    The prototype of the Borexino detector Counting Test Facility, located in the Gran Sasso laboratory, has been used to obtain a bound on the stability of the electron. The new lower limit on the mean lifetime defined on 32.1 days of data set is τ(e - → γ + ν e ) ≥ 4.6 · 10 26 years (90 % C.L.)

  10. FreeDam - A webtool for free-electron laser-induced damage in femtosecond X-ray crystallography

    Science.gov (United States)

    Jönsson, H. Olof; Östlin, Christofer; Scott, Howard A.; Chapman, Henry N.; Aplin, Steve J.; Tîmneanu, Nicuşor; Caleman, Carl

    2018-03-01

    Over the last decade X-ray free-electron laser (XFEL) sources have been made available to the scientific community. One of the most successful uses of these new machines has been protein crystallography. When samples are exposed to the intense short X-ray pulses provided by the XFELs, the sample quickly becomes highly ionized and the atomic structure is affected. Here we present a webtool dubbed FreeDam based on non-thermal plasma simulations, for estimation of radiation damage in free-electron laser experiments in terms of ionization, temperatures and atomic displacements. The aim is to make this tool easily accessible to scientists who are planning and performing experiments at XFELs.

  11. IMP metabolism in human skeletal muscle after exhaustive exercise

    DEFF Research Database (Denmark)

    Tullson, P. C.; Bangsbo, Jens; Hellsten, Ylva

    1995-01-01

    This study addressed whether AMP deaminase (AMPD)myosin binding occurs with deamination during intense exercise in humans and the extent of purine loss from muscle during the initial minutes of recovery. Male subjects performed cycle exercise (265 +/- 2 W for 4.39 +/- 0.04 min) to stimulate muscle...... inosine 5'-monophosphate (IMP) formation. After exercise, blood flow to one leg was occluded. Muscle biopsies (vastus lateralis) were taken before and 3.6 +/- 0.2 min after exercise from the occluded leg and 0.7 +/- 0.0, 1.1 +/- 0.0, and 2.9 +/- 0.1 min postexercise in the nonoccluded leg. Exercise...... activated AMPD; at exhaustion IMP was 3.5 +/- 0.4 mmol/kg dry muscle. Before exercise, 16.0 +/- 1.6% of AMPD cosedimented with the myosin fraction; the extent of AMPD:myosin binding was unchanged by exercise. Inosine content increased about threefold during exercise and twofold more during recovery; by 2...

  12. The effect of electron scattering from disordered grain boundaries on the resistivity of metallic nanostructures

    International Nuclear Information System (INIS)

    Arenas, Claudio; Henriquez, Ricardo; Moraga, Luis; Muñoz, Enrique; Munoz, Raul C.

    2015-01-01

    (in the allowed KP bands) that transmit electrons unhindered, without reflections, while the electrons in the forbidden KP bands are localized. A distinctive feature of the quantum theory is that it provides a description of the temperature dependence of the resistivity where the contribution to the resistivity originating on electron-grain boundary scattering can be identified by a certain unique grain boundary reflectivity R, and the resistivity arising from electron-impurity scattering can be identified by a certain unique ℓ IMP mean free path attributable to impurity scattering. This is in contrast to the classical theory of Mayadas and Shatzkes (MS), that does not discriminate properly between a resistivity arising from electron-grain boundary scattering and that arising from electron-impurity scattering, for MS theory does not allow parameters (ℓ IMP , R) to be uniquely adjusted to describe the temperature dependence of the resistivity data. The same data can be described using different sets of (R, ℓ IMP ); the latter parameter can be varied by two orders of magnitude in the case of small grained samples d < ℓ, and by a factor of 4 in the case of samples made out of large grains d > ℓ (where ℓ is the bulk mean free path at 300 K). For samples d > ℓ, the increase of resistivity is attributed not to electrons being partially reflected by the grain boundaries, but to a decrease in the number of states at the Fermi sphere that are allowed bands of the KP potential; hence the reflectivity required by the quantum model turns out to be an order of magnitude smaller than that required by the classical MS theory. For samples d < ℓ, the resistivity increase originates mainly from Anderson localization induced by electron grain boundary scattering from disordered successive grains characterized by a localization length of the order of 110 nm and not from electrons being partially reflected by grain boundaries; the outcome is that the reflectivity required

  13. The effect of electron scattering from disordered grain boundaries on the resistivity of metallic nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Arenas, Claudio [Departamento de Física, Facultad de Ciencias Físicas y Matemáticas, Universidad de Chile, Blanco Encalada 2008, Casilla 487-3, Santiago 8370449 (Chile); Synopsys Inc., Avenida Vitacura 5250, Oficina 708, Vitacura, Santiago (Chile); Henriquez, Ricardo [Departamento de Física, Universidad Técnica Federico Santa María, Av. España 1680, Casilla 110-V, Valparaíso (Chile); Moraga, Luis [Universidad Central de Chile, Toesca 1783, Santiago (Chile); Muñoz, Enrique [Facultad de Física, Pontificia Universidad Católica de Chile, Casilla 306, Santiago 7820436 (Chile); Munoz, Raul C., E-mail: ramunoz@ing.uchile.cl [Departamento de Física, Facultad de Ciencias Físicas y Matemáticas, Universidad de Chile, Blanco Encalada 2008, Casilla 487-3, Santiago 8370449 (Chile)

    2015-02-28

    (in the allowed KP bands) that transmit electrons unhindered, without reflections, while the electrons in the forbidden KP bands are localized. A distinctive feature of the quantum theory is that it provides a description of the temperature dependence of the resistivity where the contribution to the resistivity originating on electron-grain boundary scattering can be identified by a certain unique grain boundary reflectivity R, and the resistivity arising from electron-impurity scattering can be identified by a certain unique ℓ{sub IMP} mean free path attributable to impurity scattering. This is in contrast to the classical theory of Mayadas and Shatzkes (MS), that does not discriminate properly between a resistivity arising from electron-grain boundary scattering and that arising from electron-impurity scattering, for MS theory does not allow parameters (ℓ{sub IMP}, R) to be uniquely adjusted to describe the temperature dependence of the resistivity data. The same data can be described using different sets of (R, ℓ{sub IMP}); the latter parameter can be varied by two orders of magnitude in the case of small grained samples d < ℓ, and by a factor of 4 in the case of samples made out of large grains d > ℓ (where ℓ is the bulk mean free path at 300 K). For samples d > ℓ, the increase of resistivity is attributed not to electrons being partially reflected by the grain boundaries, but to a decrease in the number of states at the Fermi sphere that are allowed bands of the KP potential; hence the reflectivity required by the quantum model turns out to be an order of magnitude smaller than that required by the classical MS theory. For samples d < ℓ, the resistivity increase originates mainly from Anderson localization induced by electron grain boundary scattering from disordered successive grains characterized by a localization length of the order of 110 nm and not from electrons being partially reflected by grain boundaries; the outcome is that the

  14. Short wavelength optics for future free electron lasers

    International Nuclear Information System (INIS)

    Attwood, D.T.

    1984-04-01

    Although much free-electron laser work is directed toward achieving sufficient single-pass gain to be useful for research purposes, the availability of mirrors of high reflectance for the vacuum ultraviolet and soft x-ray regime would make resonant cavities a possibility. In addition, as in ordinary synchrotron radiation work, mirrors are required for the construction of realistic experiments and for beam manipulation purposes such as folding and extraction. The Working Group discussed a number of approaches to reflecting optics for free electron lasers, which are summarized here, and described in some detail. 16 references, 2 figures

  15. Automatic tuning of free electron lasers

    Energy Technology Data Exchange (ETDEWEB)

    Agapov, Ilya; Zagorodnov, Igor [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Geloni, Gianluca [European XFEL, Schenefeld (Germany); Tomin, Sergey [European XFEL, Schenefeld (Germany); NRC Kurchatov Institute, Moscow (Russian Federation)

    2017-04-07

    Existing FEL facilities often suffer from stability issues: so electron orbit, transverse electron optics, electron bunch compression and other parameters have to be readjusted often to account for drifts in performance of various components. The tuning procedures typically employed in operation are often manual and lengthy. We have been developing a combination of model-free and model-based automatic tuning methods to meet the needs of present and upcoming XFEL facilities. Our approach has been implemented at FLASH to achieve automatic SASE tuning using empirical control of orbit, electron optics and bunch compression. In this paper we describe our approach to empirical tuning, the software which implements it, and the results of using it at FLASH.We also discuss the potential of using machine learning and model-based techniques in tuning methods.

  16. Automatic tuning of free electron lasers

    International Nuclear Information System (INIS)

    Agapov, Ilya; Zagorodnov, Igor; Geloni, Gianluca; Tomin, Sergey

    2017-01-01

    Existing FEL facilities often suffer from stability issues: so electron orbit, transverse electron optics, electron bunch compression and other parameters have to be readjusted often to account for drifts in performance of various components. The tuning procedures typically employed in operation are often manual and lengthy. We have been developing a combination of model-free and model-based automatic tuning methods to meet the needs of present and upcoming XFEL facilities. Our approach has been implemented at FLASH to achieve automatic SASE tuning using empirical control of orbit, electron optics and bunch compression. In this paper we describe our approach to empirical tuning, the software which implements it, and the results of using it at FLASH.We also discuss the potential of using machine learning and model-based techniques in tuning methods.

  17. Coherent Startup of an Infrared Free-Electron Laser

    NARCIS (Netherlands)

    Jaroszynski, D. A.; Bakker, R. J.; van der Meer, A. F. G.; Oepts, D.; van Amersfoort, P. W.

    1993-01-01

    Coherent enhancement of the spontaneous undulator radiation by several orders of magnitude has been observed in a free-electron laser at wavelengths from 40 to 100 mum. The coherent emission can be explained by details of the electron-beam micropulse structure. Furthermore, it has been found that

  18. X-ray Free-electron Lasers

    Energy Technology Data Exchange (ETDEWEB)

    Feldhaus, J.; /DESY; Arthur, J.; Hastings, J.B.; /SLAC

    2007-02-23

    In a free-electron laser (FEL) the lasing medium is a high-energy beam of electrons flying with relativistic speed through a periodic magnetic field. The interaction between the synchrotron radiation that is produced and the electrons in the beam induces a periodic bunching of the electrons, greatly increasing the intensity of radiation produced at a particular wavelength. Depending only on a phase match between the electron energy and the magnetic period, the wavelength of the FEL radiation can be continuously tuned within a wide spectral range. The FEL concept can be adapted to produce radiation wavelengths from millimeters to Angstroms, and can in principle produce hard x-ray beams with unprecedented peak brightness, exceeding that of the brightest synchrotron source by ten orders of magnitude or more. This paper focuses on short-wavelength FELs. It reviews the physics and characteristic properties of single-pass FELs, as well as current technical developments aiming for fully coherent x-ray radiation pulses with pulse durations in the 100 fs to 100 as range. First experimental results at wavelengths around 100 nm and examples of scientific applications planned on the new, emerging x-ray FEL facilities are presented.

  19. Modification of the electronic transport in Au by prototypical impurities and interlayers

    KAUST Repository

    Fadlallah, Majida M.

    2010-02-01

    Electronic transport calculations for metallic interfaces based on density functional theory and a scattering theory on the Landauer-Büttiker level are presented. We study the modifications of the transport through Au due to prototypical impurities and interlayers. Our results show that the influence of S and Si impurities is well described in terms of simple vacancies. Metallic impurities and interlayers, on the other hand, have even more drastic effects, in particular when the Au s-d hybrid states at the Fermi energy are perturbed. The effects of a possible interface alloy formation are discussed in detail. © 2010 EPLA.

  20. Modification of the electronic transport in Au by prototypical impurities and interlayers

    KAUST Repository

    Fadlallah, Majida M.; Schuster, Cosima B.; Eckern, Ulrich; Schwingenschlö gl, Udo

    2010-01-01

    Electronic transport calculations for metallic interfaces based on density functional theory and a scattering theory on the Landauer-Büttiker level are presented. We study the modifications of the transport through Au due to prototypical impurities and interlayers. Our results show that the influence of S and Si impurities is well described in terms of simple vacancies. Metallic impurities and interlayers, on the other hand, have even more drastic effects, in particular when the Au s-d hybrid states at the Fermi energy are perturbed. The effects of a possible interface alloy formation are discussed in detail. © 2010 EPLA.

  1. Making texts in electronic health records comprehensible to consumers: a prototype translator.

    Science.gov (United States)

    Zeng-Treitler, Qing; Goryachev, Sergey; Kim, Hyeoneui; Keselman, Alla; Rosendale, Douglas

    2007-10-11

    Narrative reports from electronic health records are a major source of content for personal health records. We designed and implemented a prototype text translator to make these reports more comprehensible to consumers. The translator identifies difficult terms, replaces them with easier synonyms, and generates and inserts explanatory texts for them. In feasibility testing, the application was used to translate 9 clinical reports. Majority (68.8%) of text replacements and insertions were deemed correct and helpful by expert review. User evaluation demonstrated a non-statistically significant trend toward better comprehension when translation is provided (p=0.15).

  2. The read-out electronics of the AMS prototype RICH detector

    International Nuclear Information System (INIS)

    Gallin-Martel, L.; Eraud, L.; Pouxe, J.; Aguayo de Hoyos, P.; Marin Munoz, J.; Martinez Botella, G.

    2003-01-01

    A Ring Imaging Cherenkov (RICH) counter dedicated to the AMS experiment is under development. An integrated circuit has been designed with the Austriamicrosystems 0.6 πm CMOS technology to process the signals of the 16 anode PMTs used in the photon detection. To improve the detector compactness, the read out electronics is placed very close to the PMTs. This lead to the design of a detection cell that comprises: a light guide, a PMT, a high voltage divider, an analog front end chip and an analog to digital converter. The analog front-end chips were extensively and successfully tested in a laboratory environment, 96 of them are now mounted on the RICH prototype. Tests with cosmic rays have started. Ion beam tests are planed in a near future. (authors)

  3. Los Alamos advanced free-electron laser

    Science.gov (United States)

    Chan, K. C. D.; Kraus, R. H.; Ledford, J.; Meier, K. L.; Meyer, R. E.; Nguyen, D.; Sheffield, R. L.; Sigler, F. L.; Young, L. M.; Wang, T. S.; Wilson, W. L.; Wood, R. L.

    1992-07-01

    Los Alamos researchers are building a free-electron laser (FEL) for industrial, medical, and research applications. This FEL, which will incorporate many of the new technologies developed over the last decade, will be compact, robust, and user-friendly. Electrons produced by a photocathode will be accelerated to 20 MeV by a high-brightness accelerator and transported by permanent-magnet quadrupoles and dipoles. The resulting electron beam will have an excellent instantaneous beam quality of 10πmm mrad in transverse emittance and 0.3% in energy spread at a peak current up to 300 A. Including operation at higher harmonics, the laser wavelength extends from 3.7 μm to 0.4 μm.

  4. Compact two-beam push-pull free electron laser

    Science.gov (United States)

    Hutton, Andrew [Yorktown, VA

    2009-03-03

    An ultra-compact free electron laser comprising a pair of opposed superconducting cavities that produce identical electron beams moving in opposite directions such that each set of superconducting cavities accelerates one electron beam and decelerates the other electron beam. Such an arrangement, allows the energy used to accelerate one beam to be recovered and used again to accelerate the second beam, thus, each electron beam is decelerated by a different structure than that which accelerated it so that energy exchange rather than recovery is achieved resulting in a more compact and highly efficient apparatus.

  5. Free-electron laser theory

    International Nuclear Information System (INIS)

    Dattoli, G.; Torre, A.

    1989-01-01

    The essential features of the theory of the free electron laser (FEL) are given in some detail. Beginning with an explanation of the basic gain mechanism, the lectures continue with a discussion of the problems associated with single-passage and recirculated (storage-ring) operation. Pulse propagation effects and the so-called 'lethargic' behaviour are analysed more completely. Finally, elements of FEL quantum theory are reported, in order to clarify the laser process from the microscopic point of view. Appendices give a fuller treatment of optical cavities and undulator magnets. (orig.)

  6. Regional cerebral blood flow in various pediatric neurological patients using 123I-IMP SPECT

    International Nuclear Information System (INIS)

    Konishi, Tohru; Naganuma, Yoshihiro; Hongou, Kazuhisa; Murakami, Miyako; Yamatani, Miwa; Okada, Toshio

    1988-01-01

    The recent development of a new radiopharmaceutical 123 I-isopropyl-iodoamphetamine (IMP), which is taken up by the brain from the blood flow, has offered a possibility of constructing scintigraphy maps of regional cerebral blood flow (rCBF) using single photon emission CT. We used this mehtod in various pediatric neurological diseases. Six patients with cerebro-vascular disorders (moya-moya disease 2, infarction 3 and HHE syndrome 1), 6 patients with infectious diseases of CNS (acute encephalitis 4, septic meningitis 1 and SSPE 1) and a miscellaneous group of six patients were studied. The rCBF abnormalities in cerebro-vascular diseases were more extensive and frequent than x-ray CT abnormalities. Repeated studies of IMP-SPECT revealed usefulness for the understanding of changeable hemodynamic pathophysiology and for the judgment of theraptic effectiveness and prognosis. The rCBF decrease in infectious diseases tended to be more diffuse and slight than that in cerebro-vascular diseases. In almost all patients, the area of rCBF decrease coincided with the area of EEG slowing evaluated by EEG topographic analysis. Brain imaging using 123 I-IMP SPECT may reveal functional abnormalities as well as organic lesions. 123 I-IMP SPECT has introduced a new era for the useful application of nuclear medicine to the investigation of pediatric neurological diseases. (author)

  7. A new far infrared free-electron laser

    CERN Document Server

    Walsh, J E; Swartz, J C; Urata, J; Kimmitt, M F

    1999-01-01

    The operation of a new ultra compact diffraction grating coupled free-electron laser (FEL) has been demonstrated. The basic elements of the device which is termed a grating coupled oscillator (GCO) are the beam in a scanning electron microscope (SEM) and a diffraction grating which is mounted in the e-beam focal region of the SEM. The e-beam is controlled by the SEM's electron optical system and distributed feed back is provided by the grating itself. Recent experimental results are presented and techniques for extending the wavelength and power coverage are discussed.

  8. A new far infrared free-electron laser

    International Nuclear Information System (INIS)

    Walsh, J.E.; Brownell, J.H.; Swartz, J.C.; Urata, J.; Kimmitt, M.F.

    1999-01-01

    The operation of a new ultra compact diffraction grating coupled free-electron laser (FEL) has been demonstrated. The basic elements of the device which is termed a grating coupled oscillator (GCO) are the beam in a scanning electron microscope (SEM) and a diffraction grating which is mounted in the e-beam focal region of the SEM. The e-beam is controlled by the SEM's electron optical system and distributed feed back is provided by the grating itself. Recent experimental results are presented and techniques for extending the wavelength and power coverage are discussed

  9. A new far infrared free-electron laser

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, J.E.; Brownell, J.H.; Swartz, J.C.; Urata, J.; Kimmitt, M.F

    1999-06-01

    The operation of a new ultra compact diffraction grating coupled free-electron laser (FEL) has been demonstrated. The basic elements of the device which is termed a grating coupled oscillator (GCO) are the beam in a scanning electron microscope (SEM) and a diffraction grating which is mounted in the e-beam focal region of the SEM. The e-beam is controlled by the SEM's electron optical system and distributed feed back is provided by the grating itself. Recent experimental results are presented and techniques for extending the wavelength and power coverage are discussed.

  10. Propagation of interplanetary shock waves by observations of type II solar radio bursts on IMP-6

    International Nuclear Information System (INIS)

    Chertok, I.M.; Fomichev, V.V.

    1976-01-01

    A new interpretation of the low frequency type II solar radio bursts of 30 June 1971, and 7-8 August 1972 observed with IMP-6 satellite (Malitson, H.H., Fainberg, J. and Stone, R.G., 1973, Astrophys. Lett., vol. 14, 111; Astrophys. J., vol. 183, L35) is suggested. The analysis is carried out for two models of the electron density distribution in the interplanetary medium taking into account that N approximately 3.5 cm -3 at a distance of 1 a.u. It is assumed that the frequency of the radio emission corresponds to the average electron density behind the shock front which exceeds the undisturbed electron density by the factor of 3. The radio data indicate essential deceleration of the shock waves during propagation from the Sun up to 1 a.u. The characteristics of the shock waves obtained from the type II bursts agree with the results of the in situ observations. (author)

  11. Wave function of free electron in a strong laser plasma

    International Nuclear Information System (INIS)

    Zhu Shitong; Shen Wenda; Guo Qizhi

    1993-01-01

    The wave function of free electron in a strong laser plasma is obtained by solving exactly the Dirac equation in a curved space-time with optical metric for the laser plasma. When the laser field is diminished to zero, the wave function is naturally reduced to relativistic wave function of free electron. The possible application of the wave function is discussed

  12. The waveguide Free-Electron Laser. 14

    International Nuclear Information System (INIS)

    Walsh, J.E.

    1990-01-01

    The general characteristics of free-electron lasers (FELs) which employ a waveguiding structure to confine electromagnetic fields and to couple them to the electron beam is discussed. The mode structure of the basic parallel plate waveguide and its adaptation via quasi-optical techniques to FEL resonator design are considered in detail. A summary of the theory of FEL systems which depend intrinsically on a guide structure (micro-undulator, Cerenkov and metal-grating FELs) and a review of progress on waveguide FEL experiments are also presented. (author). 44 refs.; 16 figs

  13. The theoretical study of the optical klystron free electron laser

    International Nuclear Information System (INIS)

    Yang Zhenhua

    2001-01-01

    The work of the theoretical study and numerical simulation of optical klystron free electron laser is supported by National 863 Research Development Program and National Science Foundation of China. The object of studying UV band free electron laser (FEL) is to understand the physical law of optical klystron FEL and to gain experience for design. A three-dimensional code OPFEL are made and it is approved that the code is correct completely. The magnetic field of the optical klystron, the energy modulation of the electron beam, the density modulation of the electron beam, spontaneous emission of the electron beam in optical klystron, the harmonic super-radiation of the electron beam, and the effects of the undulator magnetic field error on modulation of the electron beam energy are simulated. These results are useful for the future experiments

  14. Cerebral blood flow imaging by I-123 IMP and Tc-99m HM-PAO

    Energy Technology Data Exchange (ETDEWEB)

    Uno, Koichi; Yoshikawa, Kyosan; Minoshima, Satoshi; Imaseki, Keiko; Arimizu, Noboru; Yamaura, Akira; Uematsu, Sadao

    1988-02-01

    SPECT studies with either N-isopropyl-p-(I-123)iodo- amphetamine (I-123 IMP) or Tc-99m hexamethyl propylene amine oxime (Tc-99m HM-PAO) were cuncurrently performed in 12 patients with brain disorders, comprising cerebral infarction (7), cerebral aneurysm (one), intracranial hemorrhage (3), and subdural hematoma (one). Whereas I-123 IMP was taken up gradually into the brain, the uptake of Tc-99m-HM-PAO in the brain reached the peak immediately after the iv injection, with 90% or more remaining constant by 15 min postinjection. On early SPECT images, a high uptake of I-123 IMP was observed in the lung, and the uptake of Tc-99m HM-PAO was observed as well in the soft tissue of cervical region. In all patients except for one, decreased rCBF was observed in the lesions on both I-123 and Tc-99m SPECT scans. Both of the radiopharmaceuticals were analogous in that decreased blood flow corresponded to cerebral lesions. (Namekawa, K).

  15. Diagnosis of Joseph disease by means of N-isopropyl-p-[123I]iodoamphetamine (IMP) SPECT

    International Nuclear Information System (INIS)

    Takahashi, Naoya; Nishihara, Mamiko; Odano, Ikuo; Sakai, Kunio; Yuasa, Tatsuhiko.

    1993-01-01

    Using N-isopropyl-p-[ 123 I]iodoamphetamine (IMP) and single-photon-emission computed tomography (SPECT), we studied the regional cerebral blood flow (rCBF) in 4 Japanese patients who had been clinically diagnosed as having Joseph disease. This is the first report of rCBF measurement by means of [ 123 I]-IMP SPECT in patients with Joseph disease. Cerebellar atrophy was evaluated by means of a 5-rating scale as defined by X-ray computed tomography (X-CT). As compared with 10 normal controls (mean cerebellar CBF±SD: 66.9±6.6 ml/100 g/min), the regional CBF of the patients with Joseph disease was found to decrease significantly in the cerebellum (mean±SD: 52.8±5.3 ml/100 g/min). However, no significant relationship was found between the decrease in rCBF in the cerebellum and the degree of cerebellar atrophy as shown by X-CT. The regional CBF in the cerebellum decreased little in one patient who had severe cerebellar atrophy or in two who showed moderate atrophy. [ 123 I]-IMP SPECT demonstrates the pathological and metabolic changes in the cerebellum that do not appear on X-CT or MRI. IMP SPECT is thus shown to be useful for the diagnosis of patients with Joseph disease. (author)

  16. Tácito e o Império Romano

    Directory of Open Access Journals (Sweden)

    Fábio Duarte Joly

    2010-06-01

    Full Text Available A fortuna de Cornélio Tácito no pensamento político europeu demonstra a intensidade da recepção de sua obra nos debates sobre a natureza do poder monárquico e estratégias aristocráticas de ação na corte imperial. Neste sentido, do século XVI, Tácito foi muitas vezes tomado como um contemporâneo, num diálogo entre presente e passado, de acordo como uma noção de história entendida como magistra vitae. A bibliografia moderna sobre Tácito, de certa forma, ainda se mantém nesta trilha ao enfatizar, como objeto de estudo, primordialmente as representações taciteanas dos imperadores, de Augusto a Nero. Pretende-se, nesta comunicação, ampliar o foco de discussão, indagando-se sobre o próprio conceito de império na obra de Tácito, visando os apontar os elementos sublinhados pelo historiados latino como responsáveis pela manutenção do império de Roma, a despeito dos conflitos sociopolíticos internos.

  17. Two-dimensional optimization of free-electron-laser designs

    Science.gov (United States)

    Prosnitz, D.; Haas, R.A.

    1982-05-04

    Off-axis, two-dimensional designs for free electron lasers are described that maintain correspondence of a light beam with a synchronous electron at an optimal transverse radius r > 0 to achieve increased beam trapping efficiency and enhanced laser beam wavefront control so as to decrease optical beam diffraction and other deleterious effects.

  18. Free form CMOS electronics: Physically flexible and stretchable

    KAUST Repository

    Hussain, Muhammad Mustafa

    2015-12-07

    Free form (physically flexible and stretchable) electronics can be used for applications which are unexplored today due to the rigid and brittle nature of the state-of-the-art electronics. Therefore, we show integration strategy to rationally design materials, processes and devices to transform advanced complementary metal oxide semiconductor (CMOS) electronics into flexible and stretchable one while retaining their high performance, energy efficiency, ultra-large-scale-integration (ULSI) density, reliability and performance over cost benefit to expand its applications for wearable, implantable and Internet-of-Everything electronics.

  19. Solar wind plasma periodicities observed at 1 AU by IMP 8

    Science.gov (United States)

    Paularena, K. I.; Szabo, A.; Lazarus, A. J.

    1995-01-01

    The IMP 8 spacecraft has been in Earth orbit since 1973, gathering plasma data over one complete 22-year solar cycle. These data are being examined to look for periodicities at time scales ranging from several hours to the entire span of the data set. A 1.3-year periodicity in the radial speed observed by IMP 8 and Voyager 2 has already been reported for the years from 1987 to 1993. The periodogram method, useful for unevenly sampled data such as the IMP 8 plasma data, has been used to search for other periods. It is interesting to note that the 13-year period is not present in the out-of-the-ecliptic component of the velocity (Vz), although a 1-year period is very obvious both visually and on the periodogram. Both components show a very strong peak associated with the 11-year solar cycle variation. This work will be extended to the thermal speed (a measure of the wind's temperature) and density, although the frequent correlations between these parameters and the velocity are expected to cause similar results. Additionally, the fine resolution data will be examined for shorter time periods than are visible using the hourly average data which are appropriate for longer periods. A comparison with periods observed at other spacecraft may also be made.

  20. Atomic and free electrons in a strong light field

    CERN Document Server

    Fedorov, Mikhail V

    1997-01-01

    This book presents and describes a series of unusual and striking strong-field phenomena concerning atoms and free electrons. Some of these phenomena are: multiphoton stimulated bremsstrahlung, free-electron lasers, wave-packet physics, above-threshold ionization, and strong-field stabilization in Rydberg atoms. The theoretical foundations and causes of the phenomena are described in detail, with all the approximations and derivations discussed. All the known and relevant experiments are described too, and their results are compared with those of the existing theoretical models.An extensive ge

  1. Free electron laser as a fusion driver

    International Nuclear Information System (INIS)

    Prosnitz, D.; Schlitt, L.

    1981-01-01

    The Free Electron Laser (FEL) is shown to be a potentially attractive solution to the problem of finding a suitable short wavelength fusion driver. The design of a 3 MJ, 250 nm FEL fusion driver is discussed

  2. A detailed study of FDIRC prototype with waveform digitizing electronics in cosmic ray telescope using 3D tracks

    Science.gov (United States)

    Nishimura, K.; Dey, B.; Aston, D.; Leith, D. W. G. S.; Ratcliff, B.; Roberts, D.; Ruckman, L.; Shtol, D.; Varner, G. S.; Va'vra, J.

    2013-02-01

    We present a detailed study of a novel Cherenkov imaging detector called the Focusing DIRC (FDIRC) with waveform digitizing electronics. In this study, the FDIRC prototype has been instrumented with seven Hamamatsu H-8500 MaPMTs. Waveforms from 384 pixels are digitized with waveform sampling electronics based on the BLAB2 ASIC, operating at a sampling speed of ∼2.5 GSa/s. The FDIRC prototype was tested in a large cosmic ray telescope (CRT) providing 3D muon tracks with ∼1.5 mrad angular resolution and muon energy of Emuon> 1.6 GeV. In this study we provide a detailed analysis of the tails in the Cherenkov angle distribution as a function of various variables, compare experimental results with simulation, and identify the major contributions to the tails. We demonstrate that to see the full impact of these tails on the Cherenkov angle resolution, it is crucial to use 3D tracks, and have a full understanding of the role of reconstruction ambiguities. These issues could not be fully explored in previous FDIRC studies where the beam was perpendicular to the quartz radiator bars. This work is relevant for the final FDIRC prototype of the PID detector at SuperB, which will be tested this year in the CRT setup.

  3. A Detailed Study of FDIRC Prototype with Waveform Digitizing Electronics in Cosmic Ray Telescope Using 3D Tracks

    International Nuclear Information System (INIS)

    Nishimura, K.; Dey, B.; Aston, D.; Leith, D.W.G.S.; Ratcliff, B.; Roberts, D.; Ruckman, L.; Shtol, D.; Varner, G.S.; Va'vra, J.

    2012-01-01

    We present a detailed study of a novel Cherenkov imaging detector called the Focusing DIRC (FDIRC) with waveform digitizing electronics. In this test study, the FDIRC prototype has been instrumented with seven Hamamatsu H-8500 MaPMTs. Waveforms from ∼450 pixels are digitized with waveform sampling electronics based on the BLAB2 ASIC, operating at a sampling speed of ∼2.5 GSa/s. The FDIRC prototype was tested in a large cosmic ray telescope (CRT) providing 3D muon tracks with ∼1.5 mrad angular resolution and muon energy of E muon > 1.6 GeV. In this study we provide a detailed analysis of the tails in the Cherenkov angle distribution as a function of various variables, compare experimental results with simulation, and identify the major contributions to the tails. We demonstrate that to see the full impact of these tails on the Cherenkov angle resolution, it is crucial to use 3D tracks, and have a full understanding of the role of ambiguities. These issues could not be fully explored in previous FDIRC studies where the beam was perpendicular to the quartz radiator bars. This work is relevant for the final FDIRC prototype of the PID detector at SuperB, which will be tested this year in the CRT setup.

  4. High-energy inverse free-electron laser accelerator

    International Nuclear Information System (INIS)

    Courant, E.D.; Pellegrini, C.; Zakowicz, W.

    1985-01-01

    We study the inverse free electron laser (IFEL) accelerator and show that it can accelerate electrons to the few hundred GeV region with average acceleration rates of the order of 200 meV/m. Several possible accelerating structures are analyzed, and the effect of synchrotron radiation losses is studied. The longitudinal phase stability of accelerated particles is also analyzed. A Hamiltonian description, which takes into account the dissipative features of the IFEL accelerator, is introduced to study perturbations from the resonant acceleration. Adiabatic invariants are obtained and used to estimate the change of the electron phase space density during the acceleration process

  5. sup 123 I-IMP SPECT study on patients with amnestic syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Hanyu, Haruo; Abe, Shinei; Arai, Hisayuki; Takasaki, Masaru; Suzuki, Takanari; Abe, Kimihiko; Amino, Saburo [Tokyo Medical Coll. (Japan)

    1992-06-01

    Regional cerebral blood flow was studied using single photon emission CT (SPECT) with {sup 123}I-IMP to elucidate the pathophysiology of amnesia. Four patients with amnestic syndrome diagnosed by DSM-III-R criteria were investigated. SPECT images demonstrated definite hypoperfusion of the temporoparietal lobe and relative sparing of motorsensory and occipital cortices in two out of four patients. Since these abnormalities of regional cerebral blood flow have been considered to be characteristic findings in dementia of the Alzheimer type, two patients with temporoparietal hypoperfusion are suggested to manifest the early stage of dementia of the Alzheimer type. Our observations suggest that {sup 123}I-IMP SPECT is an useful madality in the diagnosis of the early stage of dementia of the Alzheimer type, especially in patients with only memory impairment. (author).

  6. N-isopropyl-4-[123I]iodoamphetamine (123I-IMP) products. A difference in radiochemical purity, unmetabolized fraction, and octanol extraction fraction in arterial blood and regional brain uptake in rats

    International Nuclear Information System (INIS)

    Kanai, Yasukazu; Hasegawa, Shinji; Kimura, Yasuyuki; Oku, Naohiko; Hatazawa, Jun; Ito, Hiroshi; Fukuda, Hiroshi

    2007-01-01

    N-isopropyl-4-[ 123 I]iodoamphetamine ( 123 I-IMP) is a lipophilic compound utilized for cerebral blood flow (CBF) measurement with single photon emission computed tomography (SPECT). Two different 123 I-IMP products (IMP A and IMP B ) are commercially available. We examined the radiochemical purity, unmetabolized fraction, and octanol extraction fraction in arterial blood, and the regional brain uptake of IMP A and IMP B in a rat model. IMP B (96.4%±0.08%, P A (95.5%±0.20%). The mean unmetabolized fraction in arterial blood taken at 10 min after intravenous administration of IMP B (69.5%±4.4%, P A (59.6%±2.6%). The mean octanol extraction fraction of IMP B (75.0%±1.3%, P A (67.2%±0.8%). The mean levels of radioactivity in arterial blood sampled at 10 min after injection and mean regional brain radioactivity (cerebral cortices, basal ganglia, brain stem, and cerebellum) at 10-12 min after injection were not significantly different between IMP A and IMP B . The present study indicates differences in the radiochemical purity and the unmetabolized and octanol extraction fraction in arterial blood between the two commercially available 123 I-IMP products. The appropriate octanol extraction fractions for IMP A and IMP B should be determined in humans and employed for quantitative CBF measurement in clinical SPECT. (author)

  7. Beamline for X-ray Free Electron Laser of SACLA

    International Nuclear Information System (INIS)

    Tono, K; Togashi, T; Ohashi, H; Kimura, H; Takahashi, S; Takeshita, K; Tomizawa, H; Goto, S; Inubushi, Y; Sato, T; Yabashi, M

    2013-01-01

    A beamline for X-ray free electron laser (XFEL) has been developed at SACLA, SPring-8 Angstrom Compact free electron LAser. The beamline delivers and diagnoses an XFEL beam without degrading the beam quality. The transport optics are applicable in the range of 4–30 keV with a double-crystal monochromator or 4–15 keV with either of two double-mirror systems. A photon diagnostic system of the beamline monitors intensity, photon energy, center-of-mass position, and spatial profile in shot-by-shot and non-destructive manners.

  8. Achromatic and isochronous electron beam transport for tunable free electron lasers

    International Nuclear Information System (INIS)

    Bengtsson, J.; Kim, K.J.

    1991-09-01

    We have continued the study of a suitable electron beam transport line, which is both isochronous and achromatic, for the free electron laser being designed at Lawrence Berkeley Laboratory. A refined version of the beam transport optics is discussed that accommodates two different modes of FEL wavelength tuning. For the fine tuning involving a small change of the electron beam energy, sextupoles are added to cancel the leading nonlinear dispersion. For the main tuning involving the change of the undulator gap, a practical solution of maintaining the beam matching condition is presented. Calculation of the higher order aberrations is facilitated by a newly developed code. 11 refs., 4 figs., 3 tabs

  9. Differentiating Primary CNS Lymphoma from Malignant Glioma using 123I-IMP SPECT and Arterial Spin labeling

    International Nuclear Information System (INIS)

    Ito, Tamio; Sato, Kenichi; Ozaki, Yoshimaru; Asanome, Taku; Nakamura, Hirohiko; Ono, Hidetoshi

    2016-01-01

    Using conventional CT or MRI methods, the differentiation of primary central nervous system lymphoma (PCNSL) and malignant glioma (MG) is difficult because of overlapping imaging characteristics. Pretreatment differentiation between PCNSL and MG is essential for therapeutic decision making because post operative adjuvant therapy is extremely different. We examined the utility of N-isopropyl-p-[ 123 I]iodoamphetamine SPECT (IMP SPECT) and arterial spin labeling (ASL) in differentiating PCNSL from MG. Twenty PCNSL and ten MG patients underwent IMP SPECT and ASL. Early SPECT image (E) was initiated 20 min after intravenous injection of 222 MBq 123 I-IMP, and delayed image (D) and ultrade-layed image (UD) were initiated 3 h and 24 h, respectively, after the injection. SPECT images were visually analyzed with a color-grading scale (low, iso, and high), and the tumor-to-normal activity ratio (T/N) was calculated for all three images. The pulsed ASL was performed using a 3-T system. We set regions of interest in the tumor and symmetrically in the contralateral white matter on the cerebral blood flow (CBF) map and estimated tumor blood flow (TBF)/CBF ratio (TBF/CBF). 1) IMP SPECT: (1) Visual image analysis of PCNSL cases showed high accumulation of 123 I-IMP up-take on D and UD, whereas most MG cases showed low accumulation. (2) T/Ns of PCNSL were significantly higher than those of MG on D and UD (E: 1.13 vs. 0.95, p>0.05; D: 1.23 vs. 0.86, p<0.01; UD: 1.40 vs. 0.86, p<0.01). 2) ASL: TBF/CBFs of MG were higher than those of PCNSL, particularly in glioblastoma patients [1.84 vs. 6.22 (III; 1.51, IV; 8.58)]. IMP SPECT and ASL are helpful tools for differentiating primary CNS lymphoma from MG. Using these examinations, we could perform adjuvant therapy without biopsy in deep-seated tumors. (author)

  10. Optimization of labeling conditions of n-isopropyl-p-iodoamphetamine chloridate (IMP) with radioiodine. Biological distribution studies

    International Nuclear Information System (INIS)

    Colturato, Maria Tereza

    2000-01-01

    The development of this work was based on a great interest from the medical community in the utilization of N-isopropyl-p-iodoamphetamine chloridate (IMP) labeled with 123 l, for brain perfusion evaluation. The IMP was initially characterized by: Melting Point (MP), Infrared Spectrophotometry (IR), Nuclear Magnetic Resonance Spectrometry (NMR), Elemental Analysis and High Performance Liquid Chromatography (HPLC). After having chosen the ideal method (nucleophilic substitution) to label IMP with that used Cu(I) as reducing agent and ascorbic acid as catalyzing of Cu(II), studies were performed to optimize the labeling parameters of 123 l-IMP: temperature reaction, time reaction, ascorbic acid mass, pH and molar ratio, and stability of the final product. The quality control method (ascending paper chromatographic) used to determine the radiochemistry purity showed to be efficient, fast and of easily handling for routine production. Biological distribution studies were performed with laboratory animals (mice) to determine the percent administered dose in the blood, different organs and whole body after intravenous administration of the radiopharmaceutical. Toxicological evaluation and in vitro study to determine the plasmatic protein binding were also done. The data of the biological distribution in mice have shown that the product crossed the intact blood brain barrier, for a enough time to obtain brain scintigraphic image, thus, allowing a follow up of further studies after the intravenous administration of the radiopharmaceutical. The 123 l-IMP showed a blood clearance and then the principal elimination route was the urinary. The kinetic study of 123 l-IMP, submitting blood samples data to BIEXP.BAS program, showed a biexponential pattern which allowed demonstrating that the compound presents a first phase of quick distribution and a second one slower corresponding to the equilibrium and elimination. Based on the results from radiochemical purity, stability and

  11. A clinical study of auditory hallucination by single photon emission computed tomography (SPECT) using N-isopropyl-p-[123I] iodoamphetamine (IMP)

    International Nuclear Information System (INIS)

    Gyobu, Tsuyoshi; Inao, Gyoshun; Ii, Masayasu; Matsuda, Hiroshi; Hisada, Kinichi.

    1988-01-01

    SPECT images with N-isopropyl-p-I-123 iodoamphetamine (IMP) were reviewed in 24 right-handed patients with hallucination (H Group), comprising schizophrenic disorder (20), alcohol hallucinosis (2), epileptic hallucinosis (one), and organic mental disorder (one), and 50 subjects without hallucination (non-H Group), consisting of 39 patients with mental or organic central nervous system disorder and 11 healthy volunteers. Early SPECT images showed an increased uptake of IMP in the auditory area and angular gyrus in 23 patients of H Group and 3 persons of non-H Group. A similar uptake of IMP was seen on delayed SPECT images in 12 patients of H Group and 4 patients with a history of hallucination of non-H Group. There were no SPECT findings specific to diseases. For schizophrenic patients, increased and decreased uptakes of IMP were seen in the striatolimbic region and in the bilateral frontal lobes, respectively, irrespective of hallucination. Factors contributing to increased uptake of IMP are discussed. (Namekawa, K.) 84 refs

  12. Insulin-like growth factor II mRNA binding protein 3 (IMP3) is overexpressed in prostate cancer and correlates with higher Gleason scores

    International Nuclear Information System (INIS)

    Ikenberg, Kristian; Behnke, Silvia; Gerhardt, Josefine; Mortezavi, Ashkan; Wild, Peter; Hofstädter, Ferdinand; Burger, Maximilian; Moch, Holger; Kristiansen, Glen; Fritzsche, Florian R; Zuerrer-Haerdi, Ursina; Hofmann, Irina; Hermanns, Thomas; Seifert, Helge; Müntener, Michael; Provenzano, Maurizio; Sulser, Tullio

    2010-01-01

    The oncofetal protein insulin-like growth factor II mRNA binding protein 3 (IMP3) is an important factor for cell-migration and adhesion in malignancies. Recent studies have shown a remarkable overexpression of IMP3 in different human malignant neoplasms and also revealed it as an important prognostic marker in some tumor entities. To our knowledge, IMP3 expression has not been investigated in prostate carcinomas so far. Immunohistochemical stainings for IMP3 were performed on tissue microarray (TMA) organized samples from 507 patients: 31 normal prostate tissues, 425 primary carcinomas and 51 prostate cancer metastases or castration-resistant prostate cancers (CRPC). IMP3 immunoreactivity was semiquantitatively scored and correlated with clinical-pathologic parameters including survival. IMP3 is significantly stronger expressed in prostate carcinomas compared to normal prostate tissues (p < 0.0001), but did not show significant correlation with the pT-stage, the proliferation index (MIB1), preoperative serum PSA level and the margin status. Only a weak and slightly significant correlation was found with the Gleason score and IMP3 expression failed to show prognostic significance in clinico-pathological correlation-analyses. Although IMP3 is overexpressed in a significant proportion of prostate cancer cases, which might be of importance for novel therapeutic approaches, it does not appear to possess any immediate diagnostic or prognostic value, limiting its potential as a tissue biomarker for prostate cancer. These results might be corroborated by the fact, that two independent tumor cohorts were separately reviewed

  13. Multiple purpose research complex on the basis of electron accelerators and terahertz free electron laser

    International Nuclear Information System (INIS)

    Kulipanov, G.N.

    2009-01-01

    In this report the basic positioning parameters of multiple purpose research complex are presented, the list of potential experiments and technological uses on the example of results received in the multiuser center of G.I. Budker Institut of nuclear physics Siberian department of the Russian Academy of Sciences is discussed. This research complex is directed on work in the big universities and nano technology centers. Electron accelerators is intended for development of electron-beam technologies different material modification, for production of nano powder, nano materials and solution of ecological tasks. In this work the project of multiple purpose research complex on the basis of new generation electron accelerator Il-14 and workable terahertz free electron laser is suggested. Terahertz free electron laser will be used for researches in the sphere of physics and chemistry, biology and medicine, nanotechnology engineering and different methods of nanodiagnostics.

  14. NASA-DoD Lead-Free Electronics Project. DRAFT Joint Test Report

    Science.gov (United States)

    Kessel, Kurt

    2011-01-01

    The use of conventional tin-lead (SnPb) in circuit board manufacturing is under ever-increasing political scrutiny due to increasing regulations concerning lead. The "Restriction of Hazardous Substances" (RoHS) directive enacted by the European Union (EU) and a pact between the United States National Electronics Manufacturing Initiative (NEMI), Europe's Soldertec at Tin Technology Ltd. and the Japan Electronics and Information Technology Industries Association (JEITA) are just two examples where worldwide legislative actions and partnerships/agreements are affecting the electronics industry. As a result, many global commercial-grade electronic component suppliers are initiating efforts to transition to lead-free (Pb-free) in order to retain their worldwide market. Pb-free components are likely to find their way into the inventory of aerospace or military assembly processes under current government acquisition reform initiatives. Inventories "contaminated" by Pb-free will result in increased risks associated with the manufacturing, product reliability, and subsequent repair of aerospace and military electronic systems. Although electronics for military and aerospace applications are not included in the RoHS legislation, engineers are beginning to find that the commercial industry's move towards RoHS compliance has affected their supply chain and changed their parts. Most parts suppliers plan to phase out their non-compliant, leaded production and many have already done so. As a result, the ability to find leaded components is getting harder and harder. Some buyers are now attempting to acquire the remaining SnPb inventory, if it's not already obsolete. Original Equipment Manufacturers (OEMs), depots, and support contractors have to be prepared to deal with an electronics supply chain that increasingly provides more and more parts with Pb-free finishes-some labeled no differently than their Pb counterparts-while at the same time providing the traditional Pb parts

  15. The effect of aging and smoking on N-isopropyl-p-[123I]iodoamphetamine (123I-IMP) accumulation in the human lung

    International Nuclear Information System (INIS)

    Hara, Masafumi; Tomiguchi, Seiji; Kojima, Akihiro; Nakashima, Rumi; Ooyama, Youichi; Takahashi, Mutsumasa; Matsumoto, Masanori.

    1994-01-01

    123 I-IMP clearance on dynamic lung scintigraphy was studied by two exponential compartments analysis in order to evaluate the effects of aging and smoking on the pulmonary function. Twenty-four patients (14 smokers and 10 non-smokers), referred for 123 I-IMP brain perfusion study, underwent lung dynamic scintigraphy for 42 min immediately after 123 I-IMP injection. In the non-smoking group 123 I-IMP lung clearance was delayed with aging. A significant correlation was found between aging and clearance rate in the lung. There was also a significant difference in the clearance rates between smoker and non-smoker groups. These findings suggest that smoking and aging affect the pulmonary function. (author)

  16. Design of a compact application-oriented free-electron laser

    International Nuclear Information System (INIS)

    Chan, K.C.D.; Meier, K.; Nguyen, D.; Sheffield, R.; Wang, T.S.; Warren, R.W.; Wilson, W.; Young, L.M.

    1992-01-01

    The goal of the Advanced Free-Electron Laser Project at the Los Alamos National Laboratory is to demonstrate that a free-electron laser (FEL) suitable for industrial, medical, and research applications can be built. This FEL system should be efficient, compact, robust, and user-friendly. To achieve this goal, we have incorporated advanced components presently available. Electrons produced by a photoelectron source are accelerated to 20 MeV by a high-brightness accelerator. They are transported by an emittance-preserving beamline with permanent-magnet quadrupoles and dipoles. The electron beam has excellent instantaneous beam quality better than: 2.5 π mm mrad in transverse emittance and 0.3% in energy spread at a Peak current up to 310 A. It is used to excite a FEL oscillator with a pulsed-current microwiggler. Including operation at higher harmonics, the laser wavelength extends from 3.7 μm to 0.4 μm

  17. Design of a compact application-oriented free-electron laser

    Science.gov (United States)

    Chan, K. C. D.; Meier, K.; Nguyen, D.; Sheffield, R.; Wang, T. S.; Warren, R. W.; Wilson, W.; Young, L. M.

    The goal of the Advanced Free-Electron Laser Project at the Los Alamos National Laboratory is to demonstrate that a free-electron laser (FEL) suitable for industrial, medical, and research applications can be built. This FEL system should be efficient, compact, robust, and user-friendly. To achieve this goal, we have incorporated advanced components presently available. Electrons produced by a photoelectron source are accelerated to 20 MeV by a high-brightness accelerator. They are transported by an emittance-preserving beamline with permanent-magnet quadrupoles and dipoles. The electron beam has excellent instantaneous beam quality better than: 2.5 (pi) mm mrad in transverse emittance and 0.3 percent in energy spread at a Peak current up to 310 A. It is used to excite a FEL oscillator with a pulsed-current microwiggler. Including operation at higher harmonics, the laser wavelength extends from 3.7 to 0.4 microns.

  18. Development of a prototype of a candidate camera payload

    OpenAIRE

    Oltedal, Jon Kalevi

    2016-01-01

    The second prototype for the NUTS camera module have been tested to confirm if changes made from the first prototype were successful. The first prototype suffered from noise issues when operating at the maximum clock frequency of 96MHz. This needed to be fixed for the MT9P031 image sensor to be usable in further designs. Debugging and testing using the camera prototype hardware and software proved that the prototype managed to produce noise free images with bright parts in the images. These r...

  19. Radiation safety aspects of new X-ray free electron laser facility, SACLA

    International Nuclear Information System (INIS)

    Asano, Yoshihiro

    2013-01-01

    In the safety point of view, X-ray free electron laser facilities have some characteristics in comparison with 3 rd generation synchrotron radiation facilities. One is that the high energy electrons are always injected into the beam dump and the beamlines must be constructed in the direction of the movements of electrons, and another is that the total number of accelerated electrons of X-ray free electron laser facilities is much larger than that of synchrotron radiation facilities. In addition to the importance of safety interlock systems, therefore, it is important that high energy electrons never invade into X-ray free electron laser beamlines and the amount of accelerated electron beam losses must be reduced as much as possible. At SACLA, a safety permanent magnet was installed into the X-ray light beam axis, and a beam halo monitor and beam loss monitors were installed within and around the electron transport pipes, respectively. In comparison with the SPring-8 synchrotron radiation facility, shielding design of SACLA, outline of the radiation safety systems including the monitors will be presented

  20. Free Electron Laser Induced Forward Transfer Method of Biomaterial for Marking

    Science.gov (United States)

    Suzuki, Kaoru

    Biomaterial, such as chitosan, poly lactic acid, etc., containing fluorescence agent was deposited onto biology hard tissue, such as teeth, fingernail of dog or cat, or sapphire substrate by free electron laser induced forward transfer method for direct write marking. Spin-coated biomaterial with fluorescence agent of rhodamin-6G or zinc phthalochyamine target on sapphire plate was ablated by free electron laser (resonance absorption wavelength of biomaterial : 3380 nm). The influence of the spin-coating film-forming temperature on hardness and adhesion strength of biomaterial is particularly studied. Effect of resonance excitation of biomaterial target by turning free electron laser was discussed to damage of biomaterial, rhodamin-6G or zinc phtarochyamine for direct write marking

  1. Linguagem e ideologia do Império estadunidense

    Directory of Open Access Journals (Sweden)

    Antonio Ozaí da Silva

    2010-07-01

    Full Text Available

    resenha: LOSURDO, Domenico. A linguagem do império: léxico da ideologia estadunidense. São Paulo: Boitempo, 2010, 303p.

  2. Insulin-like growth factor II mRNA binding protein 3 (IMP3 is overexpressed in prostate cancer and correlates with higher Gleason scores

    Directory of Open Access Journals (Sweden)

    Mortezavi Ashkan

    2010-06-01

    Full Text Available Abstract Background The oncofetal protein insulin-like growth factor II mRNA binding protein 3 (IMP3 is an important factor for cell-migration and adhesion in malignancies. Recent studies have shown a remarkable overexpression of IMP3 in different human malignant neoplasms and also revealed it as an important prognostic marker in some tumor entities. To our knowledge, IMP3 expression has not been investigated in prostate carcinomas so far. Methods Immunohistochemical stainings for IMP3 were performed on tissue microarray (TMA organized samples from 507 patients: 31 normal prostate tissues, 425 primary carcinomas and 51 prostate cancer metastases or castration-resistant prostate cancers (CRPC. IMP3 immunoreactivity was semiquantitatively scored and correlated with clinical-pathologic parameters including survival. Results IMP3 is significantly stronger expressed in prostate carcinomas compared to normal prostate tissues (p Conclusions Although IMP3 is overexpressed in a significant proportion of prostate cancer cases, which might be of importance for novel therapeutic approaches, it does not appear to possess any immediate diagnostic or prognostic value, limiting its potential as a tissue biomarker for prostate cancer. These results might be corroborated by the fact, that two independent tumor cohorts were separately reviewed.

  3. Characterization of the Eimeria maxima sporozoite surface protein IMP1

    Science.gov (United States)

    The purpose of this study was to characterize Eimeria maxima immunoprotective protein IMP1 that is hypothesized to play a role in eliciting protective immunity against E. maxima infection in chickens. RT-PCR analysis of RNA from unsporulated and sporulating E. maxima oocysts revealed highest transc...

  4. Regional cerebral blood flow in various pediatric neurological patients using /sup 123/I-IMP SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Konishi, Tohru; Naganuma, Yoshihiro; Hongou, Kazuhisa; Murakami, Miyako; Yamatani, Miwa; Okada, Toshio

    1988-03-01

    The recent development of a new radiopharmaceutical /sup 123/I-isopropyl-iodoamphetamine (IMP), which is taken up by the brain from the blood flow, has offered a possibility of constructing scintigraphy maps of regional cerebral blood flow (rCBF) using single photon emission CT. We used this mehtod in various pediatric neurological diseases. Six patients with cerebro-vascular disorders (moya-moya disease 2, infarction 3 and HHE syndrome 1), 6 patients with infectious diseases of CNS (acute encephalitis 4, septic meningitis 1 and SSPE 1) and a miscellaneous group of six patients were studied. The rCBF abnormalities in cerebro-vascular diseases were more extensive and frequent than x-ray CT abnormalities. Repeated studies of IMP-SPECT revealed usefulness for the understanding of changeable hemodynamic pathophysiology and for the judgment of theraptic effectiveness and prognosis. The rCBF decrease in infectious diseases tended to be more diffuse and slight than that in cerebro-vascular diseases. In almost all patients, the area of rCBF decrease coincided with the area of EEG slowing evaluated by EEG topographic analysis. Brain imaging using /sup 123/I-IMP SPECT may reveal functional abnormalities as well as organic lesions. /sup 123/I-IMP SPECT has introduced a new era for the useful application of nuclear medicine to the investigation of pediatric neurological diseases.

  5. Ponderomotive Generation and Detection of Attosecond Free-Electron Pulse Trains

    Science.gov (United States)

    Kozák, M.; Schönenberger, N.; Hommelhoff, P.

    2018-03-01

    Atomic motion dynamics during structural changes or chemical reactions have been visualized by pico- and femtosecond pulsed electron beams via ultrafast electron diffraction and microscopy. Imaging the even faster dynamics of electrons in atoms, molecules, and solids requires electron pulses with subfemtosecond durations. We demonstrate here the all-optical generation of trains of attosecond free-electron pulses. The concept is based on the periodic energy modulation of a pulsed electron beam via an inelastic interaction, with the ponderomotive potential of an optical traveling wave generated by two femtosecond laser pulses at different frequencies in vacuum. The subsequent dispersive propagation leads to a compression of the electrons and the formation of ultrashort pulses. The longitudinal phase space evolution of the electrons after compression is mapped by a second phase-locked interaction. The comparison of measured and calculated spectrograms reveals the attosecond temporal structure of the compressed electron pulse trains with individual pulse durations of less than 300 as. This technique can be utilized for tailoring and initial characterization of suboptical-cycle free-electron pulses at high repetition rates for stroboscopic time-resolved experiments with subfemtosecond time resolution.

  6. Plug-and-play paper-based toolkit for rapid prototyping of microfluidics and electronics towards point-of-care diagnostic solutions

    CSIR Research Space (South Africa)

    Smith, S

    2015-11-01

    Full Text Available We present a plug-and-play toolkit for the rapid assembly of paper-based microfluidic and electronic components for quick prototyping of paper-based components towards point-of-care diagnostic solutions. Individual modules, each with a specific...

  7. The Livermore Free-Electron Laser Program Magnet Test Laboratory

    International Nuclear Information System (INIS)

    Burns, M.J.; Kulke, B.; Deis, G.A.; Frye, R.W.; Kallman, J.S.; Ollis, C.W.; Tyler, G.C.; Van Maren, R.D.; Weiss, W.C.

    1987-01-01

    The Lawrence Livermore National Laboratory (LLNL) Free-Electron Laser Program Magnet Test Laboratory supports the ongoing development of the Induction Linac Free Electron Laser (IFEL) and uses magnetic field measurement systems that are useful in the testing of long periodic magnetic structures, electron-beam transport magnets, and spectrometer magnets. The major systems described include two computer-controlled, three-axis Hall probe-and-search coil transports with computer-controlled data acquisition; a unique, automated-search coil system used to detect very small inaccuracies in wiggler fields; a nuclear magnetic resonance (NMR)-based Hall probe-calibration facility; and a high-current DC ion source using heavy ions of variable momentum to model the transport of high-energy electrons. Additionally, a high-precision electron-beam-position monitor for use within long wigglers that has a positional resolution of less than 100 μm is under development in the laboratory and will be discussed briefly. Data transfer to LLNL's central computing facility and on-line graphics enable us to analyze large data sets quickly. 3 refs

  8. Clinical utility of N-isopropyl-p-[123I] iodoamphetamine (123I-IMP) for SPECT in epileptic children

    International Nuclear Information System (INIS)

    Taki, Kuniyasu; Seto, Hikaru; Futatsuya, Ryusuke; Kakishita, Masao; Seki, Hiroyasu.

    1989-01-01

    A regional cerebral perfusion study was performed in epileptic children using single photon emission computed tomography (SPECT) and N-isopropyl-p-[ 123 I] iodoamphetamine ( 123 I-IMP). A total of 22 patients with epilepsy underwent both a 123 I-IMP brain perfusion study and X-ray CT. Eighteen had positive and four had negative perfusion study results. Of the eighteen patients with positive perfusion study results, two were positive on X-ray CT. In these two patients, the areas of perfusion defects were larger than those of low density on X-ray CT. In only four patients did the areas of perfusion defects correspond to the sites of abnormal EEG. In conclusion, 123 I-IMP perfusion study is of great clinical value in pediatric epileptic cases. (author)

  9. 3',5'-cIMP as Potential Second Messenger in the Vascular Wall.

    Science.gov (United States)

    Leung, Susan W S; Gao, Yuansheng; Vanhoutte, Paul M

    2017-01-01

    Traditionally, only the 3',5'-cyclic monophosphates of adenosine and guanosine (produced by adenylyl cyclase and guanylyl cyclase, respectively) are regarded as true "second messengers" in the vascular wall, despite the presence of other cyclic nucleotides in different tissues. Among these noncanonical cyclic nucleotides, inosine 3',5'-cyclic monophosphate (cIMP) is synthesized by soluble guanylyl cyclase in porcine coronary arteries in response to hypoxia, when the enzyme is activated by endothelium-derived nitric oxide. Its production is associated with augmentation of vascular contraction mediated by stimulation of Rho kinase. Based on these findings, cIMP appears to meet most, if not all, of the criteria required for it to be accepted as a "second messenger," at least in the vascular wall.

  10. Second harmonic generation in Te crystal using free electron laser

    CERN Document Server

    Yamauchi, T; Minehara, E J

    2002-01-01

    The second harmonic generation signal converted from the fundamental wavelength of 22 mu m of a free electron laser was observed for the first time using a birefringent Te crystal. The experimental conversion efficiency of Te crystal for second harmonic generation is 0.53%, which is equivalent to the theoretical value within a factor of 2. The Te crystal has been incorporated into an autocorrelator system to measure the micro-pulse width of infrared free electron laser successfully. (author)

  11. Elsa: an infrared free electron laser

    International Nuclear Information System (INIS)

    Guimbal, P.; Chaix, P.

    1998-01-01

    Since the first experiments, twenty years ago, free-electron lasers (FEL) have known a strong development because of their promise: broadband tunability from X-rays to microwaves and high (peak or average) power, limited only by technological issues. ELSA has been designed as a research tool to investigate the physics of high-power FELs. After a brief introduction of the FEL field of research, we point out the unique characteristics of ELSA and why it is a valuable tool for the study of FEL interaction in the strong electron-photon coupling. The main experimental results are reviewed. We conclude on the concept of Two-Frequency-Wiggler. (author)

  12. Portosystemic shunting in portal hypertension: evaluation with portal scintigraphy with transrectally administered I-123 IMP

    International Nuclear Information System (INIS)

    Kashiwagi, T.; Azuma, M.; Ikawa, T.; Takehara, T.; Matsuda, H.; Yoshioka, H.; Mitsutani, N.; Koizumi, T.; Kimura, K.

    1988-01-01

    Portosystemic shunting was evaluated with rectal administration of iodine-123 iodoamphetamine (IMP) in seven patients without liver disease and 53 patients with liver cirrhosis. IMP (2-3 mCi [74-111 MBq]) was administered to the rectum through a catheter. Images of the chest and abdomen were obtained for up to 60 minutes with a scintillation camera interfaced with a computer. In all patients, images of the liver and/or lungs were observed within 5-10 minutes and became clear with time. In patients without liver disease, only liver images could be obtained, whereas the lung was visualized with or without the liver in all patients with liver cirrhosis. The portosystemic shunt index was calculated by dividing counts of lungs by counts of liver and lung. These values were significantly higher in liver cirrhosis, especially in the decompensated stage. Transrectal portal scintigraphy with IMP appears to be a useful method for noninvasive and quantitative evaluation of portosystemic shunting in portal hypertension

  13. Free-electron laser system with Raman amplifier outcoupling

    Energy Technology Data Exchange (ETDEWEB)

    Linford, G.J.

    1988-05-03

    A free-electron laser system is described comprising: a free-electron laser pump beam generator producing a high-power optical output beam in a vacuum environement; a Raman amplifier cell located in the path of the output beam from the pump beam generator; means for generating and introducing a Stokes seed beam into the Raman amplifier cell, a pair of gaseous windows through which the output beam enters and leaves the Raman amplifier cell, each window having a stream of gas moving continuously in a direction generally perpendicular to the beam; and a mirror positioned in the path of the output beam from the Raman amplifier, the mirror functioning to reflect and further direct the output beam, but not the unwanted spectral components.

  14. Determination of trace element mineral/liquid partition coefficients in melilite and diopside by ion and electron microprobe techniques

    Science.gov (United States)

    Kuehner, S. M.; Laughlin, J. R.; Grossman, L.; Johnson, M. L.; Burnett, D. S.

    1989-01-01

    The applicability of ion microprobe (IMP) for quantitative analysis of minor elements (Sr, Y, Zr, La, Sm, and Yb) in the major phases present in natural Ca-, Al-rich inclusions (CAIs) was investigated by comparing IMP results with those of an electron microprobe (EMP). Results on three trace-element-doped glasses indicated that it is not possible to obtain precise quantitative analysis by using IMP if there are large differences in SiO2 content between the standards used to derive the ion yields and the unknowns.

  15. IMP-SPECT at patients with hallucinations

    International Nuclear Information System (INIS)

    Podreka, I.; Mamoli, B.; Lesch, O.; Suess, E.; Wimberger, D.; Mayr, N.; Havelec, L.; Mueller, C.; Steiner, M.; Deecke, L.

    1986-01-01

    IMP-SPECT was performed in 14 normal volunteers. A 'regional index=RI' of tracer distribution was calculated for 18 regions in each hemisphere RI=(cts/voxel ROI)/(mean cts/voxel of all ROI's). 30 seizure patients (E) and 12 patients with acoustic, partialy also visual hallucinations (H) were investigated. Regions were defined as hypo- or hyperperfused if the RI exceeded the value of the corresponding normal-RI +- 2 std. EEG was recorded in all (E). 93.3% of EEG-findings were abnormal, 50% showed a focus, 46.7% paroxysmal activity. SPECT detected in 93.3% of (E) hypoperfused regions, mostly located in the temporal lobe. All (H) had decreased rCBF, predominantly in the frontal cortex. ANOVA and t-test revealed significant RI-differences in the frontal lobe, both hippocampi, right and left inferior occipital cortex, and right anterior basal ganglia. (H) had lower RI's in frontal lobes, higher RI's in both hippocampal regions as well as inferior occipital regions and anterior basal ganglia Differences between (E) and (H) were found in the frontal lobe ((H)sub(→)), right superior temporal region ((H)sup(→)), left hippocampus ((H)sup(→)), both inferior occipital regions ((H)sup(→)) and right anterior basal ganglia ((H)sup(→)). The study shows that by means of IMP-SPECT hypo- and hyperperfused areas can be detected in the hemispheres of (E) and (H), corresponding to disturbed brain function. Higher hippocampal CBF in (E) and (H) may be related to the role of this limbic structure in generation of seizures and psychotic states. Hallucinations are associated with increased CBF in the right temporal and associative visual cortex. (Author)

  16. Inhomogeneous effects in the quantum free electron laser

    International Nuclear Information System (INIS)

    Piovella, N.; Bonifacio, R.

    2006-01-01

    We include inhomogeneous effects in the quantum model of a free electron laser taking into account the initial energy spread of the electron beam. From a linear analysis, we obtain a generalized dispersion relation, from which the exponential gain can be explicitly calculated. We determine the maximum allowed initial energy spread in the quantum exponential regime and we discuss the limit of large energy spread

  17. A new graphic method for evaluation of distribution volume on N-isopropyl-p-[123I]iodoamphetamine (IMP) SPECT

    International Nuclear Information System (INIS)

    Odano, Ikuo; Takahashi, Naoya; Ohtaki, Hiroh; Noguchi, Eikichi; Hatano, Masayoshi; Yamasaki, Yoshihiro; Nishihara, Mamiko; Ohkubo, Masaki; Yokoi, Takashi.

    1993-01-01

    We developed a new graphic method using N-isopropyl-p-[ 123 I]iodoamphetamine (IMP) and SPECT of the brain, the graph on which all three parameters, cerebral blood flow, distribution volume (V d ) and delayed count to early count ratio (Delayed/Early ratio), were able to be evaluated simultaneously. The kinetics of 123 I-IMP in the brain was analyzed by a 2-compartment model, and a standard input function was prepared by averaging the time activity curves of 123 I-IMP in arterial blood on 6 patients with small cerebral infarction etc. including 2 normal controls. Being applied this method to the differential diagnosis between Parkinson's disease and progressive supranuclear palsy, we were able to differentiate both with a glance, because the distribution volume of the frontal lobe significantly decreased in Parkinson's disease (Mean±SD; 26±6 ml/g). This method was clinically useful. We think that the distribution volume of 123 I-IMP may reflect its retention mechanism in the brain, and the values are related to amine, especially to dopamine receptors and its metabolism. (author)

  18. A Low-Energy-Spread Rf Accelerator for a Far-Infrared Free-Electron Laser

    NARCIS (Netherlands)

    van der Geer, C. A. J.; Bakker, R. J.; van der Meer, A. F. G.; van Amersfoort, P. W.; Gillespie, W. A.; Saxon, G.; Poole, M. W.

    1993-01-01

    A high electron current and a small energy spread are essential for the operation of a free electron laser (FEL). In this paper we discuss the design and performance of the accelerator for FELIX, the free electron laser for infrared experiments. The system consists of a thermionic gun, a prebuncher,

  19. A comparison of different silver inks for printing of conductive tracks on paper substrates for rapid prototyping of electronic circuits

    CSIR Research Space (South Africa)

    Bezuidenhout, PH

    2015-11-01

    Full Text Available This study compares the performance between two commercially-available electrically conductive silver inks, Harima NPS-J nanopaste and the NBSIJ-FD02 Mitsubishi conductive ink, used in rapid prototyping of electronic circuits. The comparative...

  20. High gain free electron laser at ETA

    International Nuclear Information System (INIS)

    Orzechowski, T.J.; Prosnitz, D.; Halbach, K.

    1983-01-01

    A single pass, tapered electron wiggler and associated beam transport has been constructed at the Experimental Test Accelerator (ETA) at Lawrence Livermore National Laboratory (LLNL). The system is designed to transport 1 kA of 4.5 MeV electrons with an emittance of 30 millirad-cm. The planar wiggler is provided by a pulsed electromagnet. The interaction region is an oversized rectangular waveguide. Quadrupole fields stabilize the beam in the plane parallel to the wiggler field. The 3 meter long wiggler has a 9.8 cm period. The Free Electron Laser (FEL) will serve as an amplifier for input frequencies of 35 GHz and 140 GHz. The facility is designed to produce better than 500 Megawatts peak power

  1. Design, fabrication and low power RF testing of a prototype beta=1, 1050 MHz cavity developed for electron linac

    International Nuclear Information System (INIS)

    Sarkar, S.; Mondal, J.; Mittal, K.C.

    2013-01-01

    A single cell 1050 MHz β = 1 elliptical cavity has been designed for possible use in High energy electron accelerator. A prototype Aluminium cavity has been fabricated by die punch method and low power testing of the cavity has been carried out by using VNA. The fundamental mode frequency of the prototype cavity is found out to be 1051.38 MHz and Q (loaded) and Q0 values corresponding to 2 modes are 8439 and 10013 respectively. Cell to cell coupling coefficient is 1.82 % from measurement which matches with the designed value (1.84%). The higher order mode frequencies are also measured and electric field of the cavity is confirmed by bead pull method. Low power RF measurements on the prototype cavity indicate that the critical RF parameters (Qo, f, Kc etc) for the cavity are consistent with the designed value. (author)

  2. Research on high performance mirrors for free electron lasers

    International Nuclear Information System (INIS)

    Kitatani, Fumito

    1996-01-01

    For the stable functioning of free electron laser, high performance optical elements are required because of its characteristics. In particular in short wavelength free electron laser, since its gain is low, the optical elements having very high reflectivity are required. Also in free electron laser, since high energy noise light exists, the optical elements must have high optical breaking strength. At present in Power Reactor and Nuclear Fuel Development Corporation, the research for heightening the performance of dielectric multi-layer film elements for short wavelength is carried out. For manufacturing such high performance elements, it is necessary to develop the new materials for vapor deposition, new vapor deposition process, and the techniques of accurate substrate polishing and inspection. As the material that satisfies the requirements, there is diamond-like carbon (DLC) film, of which the properties are explained. As for the manufacture of the DLC films for short wavelength optics, the test equipment for forming the DLC films, the test of forming the DLC films, the change of the film quality due to gas conditions, discharge conditions and substrate materials, and the measurement of the optical breaking strength are reported. (K.I.)

  3. 123I-IMP single photon emission computed tomography (SPECT) study in childhood epilepsy

    International Nuclear Information System (INIS)

    Hara, Masafumi; Shimomura, Osamu; Kojima, Akihiro; Izunaga, Hiroshi; Tomiguchi, Seiji; Hirota, Yoshihisa; Taku, Keiichi; Miike, Teruhisa; Takahashi, Mutsumasa

    1990-01-01

    N-isopropyl-p[ 123 I]-iodoamphetamine (IMP) single photon emission computed tomography (SPECT), X-ray computed tomography (X-CT) and magnetic resonance imaging (MRI) were performed in 18 children with idiopathic seizures. In children with idiopathic seizures SPECT identified abnormal lesions in the highest rate (50%) compared with X-CT (11%) and MRI (13%), but the findings of SPECT poorly correlated with the foci on electroencephalography (EEG). Idiopathic epilepsy with abnormal uptake on SPECT was refractory to medical treatments and frequently associated with mental and/or developmental retardation. Perfusion defects identified on SPECT probably influenced the development of the brains in children. IMP SPECT is useful in the diagnosis and medical treatment in children with seizures. (author)

  4. 8. Seminar of the IMP-IIE-ININ on technological specialties. Topic 10: Earth Sciences; 8. Seminario IMP-IIE-ININ sobre especialidades tecnologicas. Mesa 10: Ciencias de la Tierra

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-31

    The document contains two papers within INIS subject scope which were presented at the 8th Seminar of the IMP-IIE-ININ on technological specialties. Topic 10: Earth Sciences. A separate abstract was prepared for each paper.

  5. The novel anthraquinone derivative IMP1338 induces death of human cancer cells by p53-independent S and G2/M cell cycle arrest.

    Science.gov (United States)

    Choi, Hyun Kyung; Ryu, Hwani; Son, A-Rang; Seo, Bitna; Hwang, Sang-Gu; Song, Jie-Young; Ahn, Jiyeon

    2016-04-01

    To identify novel small molecules that induce selective cancer cell death, we screened a chemical library containing 1040 compounds in HT29 colon cancer and CCD18-Co normal colon cells, using a phenotypic cell-based viability assay system with the Cell Counting Kit-8 (CCK-8). We discovered a novel anthraquinone derivative, N-(4-[{(9,10-dioxo-9,10-dihydro-1-anthracenyl)sulfonyl}amino]phenyl)-N-methylacetamide (IMP1338), which was cytotoxic against the human colon cancer cells tested. The MTT cell viability assay showed that treatment with IMP1338 selectively inhibited HCT116, HCT116 p53(-/-), HT29, and A549 cancer cell proliferation compared to that of Beas2B normal epithelial cells. To elucidate the cellular mechanism underlying the cytotoxicity of IMP1338, we examined the effect of IMP1338 on the cell cycle distribution and death of cancer cells. IMP1338 treatment significantly arrested the cell cycle at S and G2/M phases by DNA damage and led to apoptotic cell death, which was determined using FACS analysis with Annexin V/PI double staining. Furthermore, IMP1338 increased caspase-3 cleavage in wild-type p53, p53 knockout HCT116, and HT29 cells as determined using immunoblotting. In addition, IMP1338 markedly induced the phosphorylation of histone H2AX and Chk1 in both cell lines while the combination of 5-fluorouracil (5-FU) and radiation inhibited the viability of HCT116, HCT116 p53(-/-), and HT29 cells compared to 5-FU or radiation alone. Our findings indicated that IMP1338 induced p53-independent cell death through S and G2/M phase arrest as well as DNA damage. These results provide a basis for future investigations assessing the promising anticancer properties of IMP1338. Copyright © 2016. Published by Elsevier Masson SAS.

  6. ETL linac facility and free-electron lasers

    International Nuclear Information System (INIS)

    Yamazaki, T.; Noguchi, T.; Mikado, T.; Sugiyama, S.; Yamada, K.; Chiwaki, M.; Ohgaki, H.; Suzuki, R.; Sei, N.

    1993-01-01

    An outline is presented of the recent development on the ETL (Electro-technical Laboratory) electron-linac facility and storage-ring FELs (free-electron lasers). Some modifications including the injection system have been made to the linac. Four storage rings are working very well. The TERAS FEL system has been shut down after the successful oscillation around 590 nm. The new NIJI-IV FEL system has been proven to work well, and the current tunable wavelength range is over 100 nm (488-595 nm). Preparatory experiments on the FEL at shorter wavelength are underway. (author)

  7. Pathophysiologic study of chronic infarcts with I-123 isopropyl iodo-amphetamine (IMP)

    DEFF Research Database (Denmark)

    Raynaud, C; Rancurel, G; Samson, Y

    1987-01-01

    Seventeen chronic cerebral infarcts were investigated by a highly sensitive, dedicated brain single photon emission computerized tomography system using 123I-isopropyl iodoamphetamine (IMP) and 133Xe. IMP uptake was measured 10 minutes, 2 hours, and 5 hours after injection, and regional cerebral...... blood flow was measured with 133Xe. In 4 cases a positron emission tomography system was used to measure the rCBF and the regional metabolic rate of oxygen with C15O2 and 15O2. The results obtained allowed us to identify 2 abnormal zones. One, the "central area," was characterized by a severe decrease...... ischemic neuronal loss. The results stress the important role played by the peripheral area, which may be useful in establishing the prognosis and evaluating the efficacy of therapy in individual stroke cases....

  8. Incorporation of a recombinant Eimeria maxima IMP1 antigen into nanoparticles confers protective immunity against E. maxima challenge infection

    Science.gov (United States)

    The purpose of this study was to determine if incorporating a recombinant Eimeria maxima protein, namely rEmaxIMP1, into gold nanoparticles (NP) could improve the level of protective immunity against E. maxima challenge infection. Recombinant EmaxIMP1 was expressed in Escherchia coli as a poly-His f...

  9. Detection of VIM-2-, IMP-1- and NDM-1-producing multidrug resistant Pseudomonas aeruginosa in Malaysia.

    Science.gov (United States)

    Liew, Siew Mun; Rajasekaram, Ganeswrei; Puthucheary, Savithri D; Chua, Kek Heng

    2018-02-09

    The increasing incidence of carbapenem-resistant Pseudomonas aeruginosa along with the discovery of novel metallo-β-lactamases (MBLs) is of concern. In this study, the isolation of Malaysian MBL-producing P. aeruginosa clinical strains was investigated. Fifty-three P. aeruginosa clinical strains were isolated from different patients in Sultanah Aminah Hospital, Johor Bahru, Malaysia in 2015. Antimicrobial susceptibility test was conducted. Minimum inhibitory concentrations (MICs) of imipenem and meropenem were determined by Etest. The carbapenem-resistant strains were screened for MBL production by IMP-EDTA double disk synergy test (DDST), MBL imipenem/imipenem-inhibitor (IP/IPI) Etest and polymerase chain reaction (PCR). Genotyping was performed by multilocus sequence typing (MLST) analysis. Three (5.7%) clinical strains were identified as MBL producers. Multidrug resistance was observed in the three strains, and two were resistant to all the antimicrobials tested. Sequencing analysis confirmed the three strains to harbour carbapenemase genes: one with bla IMP-1 , one with bla VIM-2 and the other with bla NDM-1 genes. These multidrug resistant strains were identified as sequence type (ST) 235 and ST308. None of the bla IMP-1 and bla NDM-1 genes have been reported in Malaysian P. aeruginosa. The emergence of imipenemase 1 (IMP-1)- and New Delhi metallo-β-lactamase 1 (NDM-1)-producing P. aeruginosa in Malaysia maybe travel-associated. Copyright © 2018. Published by Elsevier Ltd.

  10. A study of crossed cerebellar diaschisis on 123I-IMP SPECT images and its redistribution phenomenon

    International Nuclear Information System (INIS)

    Odano, Ikuo; Takahashi, Naoya; Nishihara, Mamiko; Otaki, Hiro; Noguchi, Eikichi; Yamazaki, Yoshihiro; Kimura, Motomasa; Sakai, Kunio; Okubo, Masaki.

    1993-01-01

    Crossed cerebellar diaschisis (CCD) is interpreted as a functional deactivation, presumably caused by a loss of excitatory or inhibitory afferent inputs on the corticopontocerebellar pathway and others. A redistribution phenomenon (RD) is usually observed in the contralateral cerebellum with CCD on delayed images of 123 I-IMP SPECT. This phenomenon was analyzed in a view point of rCBF measurement in 24 patients with brain tumor, infarction and so forth. Regional CBF was measured by the microsphere method with 123 I-IMP and a delayed-to-early counts ratio (D/E ratio) was used. As a result, there was no relation between rCBF and the D/E ratio in the cerebellum, which means that RD is caused by other factors except for rCBF in the cerebellum. Regional CBF and the D/E ratio in the contralateral and ipsilateral cerebellum was 46.3 ml/100 g/min, 1.01 and 57.0 ml/100 g/min, 0.86, respectively. These results mean that the high activity of IMP gradually decreased in the ipsilateral cerebellum, while the low activity in the contralateral cerebellum was almost stable, and the difference of both activity reduced after 5 hours and RD was observed on the delayed image. The data indicate that retention mechanism of IMP and vascular permeability are not affected in the cerebellum with CCD. (author)

  11. Electron beam properties and impedance characterization for storage rings used for free electron lasers

    International Nuclear Information System (INIS)

    Dattoli, G.; Mezi, L.; Renieri, A.; Migliorati, M.; Walker, R.

    2000-01-01

    Good electron beam qualities and stability are the crucial features of Storage Rings dedicated to synchrotron radiation sources or to Free Electron Laser. Most of these characteristics depends on the coupling of the e-beam with the machine environment, which can be in turn modelled in terms of a characteristic impedance, whose absolute value and structure can be used to specify both the stability (longitudinal and transverse) of the beam and its qualities (energy spread, bunch length, peak current ...). In this paper are considered two specific examples of Storage Rings used for FEL operation and analyze their performances by means of semi analytical and numerical methods. The analysis is aimed at clarifying the dependence of beam energy spread and bunch length on beam current and at providing a set of parameters useful for the optimization of Free Electron Laser or synchrotron radiation sources [it

  12. Effect of two non-synonymous ecto-5'-nucleotidase variants on the genetic architecture of inosine 5'-monophosphate (IMP) and its degradation products in Japanese Black beef.

    Science.gov (United States)

    Uemoto, Yoshinobu; Ohtake, Tsuyoshi; Sasago, Nanae; Takeda, Masayuki; Abe, Tsuyoshi; Sakuma, Hironori; Kojima, Takatoshi; Sasaki, Shinji

    2017-11-13

    Umami is a Japanese term for the fifth basic taste and is an important sensory property of beef palatability. Inosine 5'-monophosphate (IMP) contributes to umami taste in beef. Thus, the overall change in concentration of IMP and its degradation products can potentially affect the beef palatability. In this study, we investigated the genetic architecture of IMP and its degradation products in Japanese Black beef. First, we performed genome-wide association study (GWAS), candidate gene analysis, and functional analysis to detect the causal variants that affect IMP, inosine, and hypoxanthine. Second, we evaluated the allele frequencies in the different breeds, the contribution of genetic variance, and the effect on other economical traits using the detected variants. A total of 574 Japanese Black cattle were genotyped using the Illumina BovineSNP50 BeadChip and were then used for GWAS. The results of GWAS showed that the genome-wide significant single nucleotide polymorphisms (SNPs) on BTA9 were detected for IMP, inosine, and hypoxanthine. The ecto-5'-nucleotidase (NT5E) gene, which encodes the enzyme NT5E for the extracellular degradation of IMP to inosine, was located near the significant region on BTA9. The results of candidate gene analysis and functional analysis showed that two non-synonymous SNPs (c.1318C > T and c.1475 T > A) in NT5E affected the amount of IMP and its degradation products in beef by regulating the enzymatic activity of NT5E. The Q haplotype showed a positive effect on IMP and a negative effect on the enzymatic activity of NT5E in IMP degradation. The two SNPs were under perfect linkage disequilibrium in five different breeds, and different haplotype frequencies were seen among breeds. The two SNPs contribute to about half of the total genetic variance in IMP, and the results of genetic relationship between IMP and its degradation products showed that NT5E affected the overall concentration balance of IMP and its degradation products

  13. The MIDAS experiment: A prototype for the microwave emission of Ultra-High Energy Cosmic Rays

    International Nuclear Information System (INIS)

    Monasor, M.; Alekotte, I.; Alvarez-Muniz, J.; Berlin, A.; Bertou, X.; Bodgan, M.; Bohacova, M.; Bonifazi, C.; Carvalho, W.; Mello Neto, J.R.T. de; Genat, J.F.; Facal San Luis, P.; Mills, E.; Rouille d'Orfeuil, B.; Wayne, S.; Reyes, L.C.; Santos, E.M.; Privitera, P.; Williams, C.; Zas, E.

    2011-01-01

    Recent measurements suggest that extensive air showers initiated by ultra-high energy cosmic rays (UHECR) emit signals in the microwave band of the electromagnetic spectrum caused by the collisions of the free-electrons with the atmospheric neutral molecules in the plasma produced by the passage of the shower. Such emission is isotropic and could allow the detection of air showers with 100% duty cycle and a calorimetric-like energy measurement, a significant improvement over current detection techniques. We have built MIDAS (MIcrowave Detection of Air Showers), a prototype of microwave detector, which consists of a 4.5 m diameter antenna with a cluster of 53 feed-horns in the 4 GHz range. The details of the prototype and first results will be presented.

  14. Clinical evaluation of Parkinson's disease using 123I-IMP SPECT

    International Nuclear Information System (INIS)

    Hayashi, Hiroko; Odano, Ikuo; Nishihara, Mamiko; Higuchi, Shouichi; Sakai, Kunio; Ishikawa, Atsushi.

    1989-01-01

    N-isopropyl-p[ 123 I]iodoamphetamine ( 123 I-IMP) SPECT and regional cerebral blood flow (rCBF) studies were performed in 20 patients with Parkinson's disease (PD) and 8 normal subjects. RCBF was measured by the arterial blood sampling method which used the microsphere model. We analized seven factors which might be related to the rCBF in PD, i.e., age, stage, duration of the disease, cerebral atrophy, severity of dementia, laterality of symptoms and motor disability score (MDS; the degree of akinesia, rigidity, tremor, gait disturbance, freezing and pulsion sign). Compared with normal subjects, global CBF (supratentorial mean rCBF) was reduced by 21.8% in PD. In particular, rCBF in the basal ganglia and that of frontal cortex were reduced by 25.3% and 24.8%, respectively. Distribution patterns of rCBF in PD were almost as same as those in normals except for cerebellum. The reduction of both rCBFs in the basal ganglia and parietal cortex significantly correlated with MDS (p 123 I-IMP SPECT study is a useful method for clinical evaluation of PD. (author)

  15. Free electron lasers and short wavelengths: state of the art and prospects

    International Nuclear Information System (INIS)

    Couprie, M.E.

    2003-01-01

    Free electron lasers generate coherent and adjustable radiation that is based on the interaction of a light wave with a relativistic electron beam circulating in a periodic and permanent magnetic field produced by an ondulator. The light wave comes from either - synchrotron radiation emitted by the electron packet at each round in the case of SASE (self amplified spontaneous emission) operating more, or - synchrotron radiation stored in an optic cavity in the case of oscillator operating mode, or - an external laser wave in the case of harmonic generation operating mode. Under particular conditions the light wave is amplified to the detriment of the kinetic energy of the electrons which leads to the laser effect. 5 free electron lasers are operating in the world: Super-Aco in France, Elettra in Italy, NIJI-4 and Uvsor in Japan, and Duke in Usa. The state of the art of free electron lasers in the UV, VUV range is presented and the different configurations associated to storage rings, linac and ERL (energy recovery linacs) are described. (A.C.)

  16. Microwave free-electron laser applications for electron cyclotron heating of plasmas

    International Nuclear Information System (INIS)

    Thomassen, K.

    1990-01-01

    Millimeter wave power may be the ideal source of heat for the plasma, but advances in technology are needed to meet requirements of next generation fusion devices. Free electron lasers (FEL) are one candidate for such sources, and this paper reviews the progress, issues of physics and technology, and potential benefits for fusion from these devices

  17. 7. Seminar of the IIE-ININ-IMP on technological specialties. Topic 10: Information Services; 7. Seminario IIE-ININ-IMP sobre especialidades tecnologicas. Mesa 10. Servicios de informacion.

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The document includes 10 papers presented at the 7. Seminar of the IIE-IMP-ININ (Mexico) on technological specialities in the field of information services (Topic 10). Three items were in INIS subject scope and a separate abstract was prepared for each of them.

  18. Analysis and assessment for the intrapulmonary kinetics of N-isopropyl-I-123-p-iodoamphetamine (IMP) in diffuse respiratory diseases

    Energy Technology Data Exchange (ETDEWEB)

    Fujishima, Seitaro (Keio Univ., Tokyo (Japan). School of Medicine)

    1992-01-01

    We investigated intrapulmonary kinetics of N-isopropyl-I-123-p-iodoamphetamine (IMP) in patients with diffuse respiratory diseases. Subjects studied were 4 healthy nonsmoking controls (age{>=}40), 3 young healthy nonsmokers (age<40), 4 healthy smokers, 8 patients with idiopathic pulmonary fibrosis (IPF), 2 with sarcoidosis, and 4 with chronic pulmonary emphysema (CPE). All studies were performed after obtaining informed consent. Ages were matched among the groups except the group of young healthy nonsmokers. We calculated the lung initial extraction fraction (E value) of IMP using Tc-99m human serum albumin as an intravascular reference tracer with deconvolution method. We also analyzed the lung IMP washout curve by a two-compartmental model. The mean E value for the nonsmoking controls was 0.977, indicating almost all IMP injected was taken up by the lungs at the initial passage. There was no difference in the E value among the groups. With regard to the lung IMP washout analysis, the distribution to the fast compartment (A{sub 1}) was smaller than that to the slow compartment (A{sub 2}). There was no difference in the A{sub 1} to A{sub 2} ratio among the groups. We then analyzed the slopes of the fast and slow compartments (k{sub 1}, k{sub 2}). There was no difference in k{sub 1} among the groups. On the other hand, k{sub 2} was larger in young healthy nonsmokers and smaller in healthy smokers, the patients with IPF, sarcoidosis and CPE than k{sub 2} in nonsmoking controls. Furthermore, k{sub 2} decreased in inverse proportion to age. We concluded that k{sub 2} could be a valuable index to detect changes of IMP, a lipophilic amine, metabolism in the lungs. (author).

  19. A new graphic method for evaluation of distribution volume on N-isopropyl-p-[[sup 123]I]iodoamphetamine (IMP) SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Odano, Ikuo; Takahashi, Naoya; Ohtaki, Hiroh; Noguchi, Eikichi; Hatano, Masayoshi; Yamasaki, Yoshihiro; Nishihara, Mamiko [Niigata Univ. (Japan). School of Medicine; Ohkubo, Masaki; Yokoi, Takashi

    1993-10-01

    We developed a new graphic method using N-isopropyl-p-[[sup 123]I]iodoamphetamine (IMP) and SPECT of the brain, the graph on which all three parameters, cerebral blood flow, distribution volume (V[sub d]) and delayed count to early count ratio (Delayed/Early ratio), were able to be evaluated simultaneously. The kinetics of [sup 123]I-IMP in the brain was analyzed by a 2-compartment model, and a standard input function was prepared by averaging the time activity curves of [sup 123]I-IMP in arterial blood on 6 patients with small cerebral infarction etc. including 2 normal controls. Being applied this method to the differential diagnosis between Parkinson's disease and progressive supranuclear palsy, we were able to differentiate both with a glance, because the distribution volume of the frontal lobe significantly decreased in Parkinson's disease (Mean[+-]SD; 26[+-]6 ml/g). This method was clinically useful. We think that the distribution volume of [sup 123]I-IMP may reflect its retention mechanism in the brain, and the values are related to amine, especially to dopamine receptors and its metabolism. (author).

  20. Inverse free electron laser accelerator for advanced light sources

    Directory of Open Access Journals (Sweden)

    J. P. Duris

    2012-06-01

    Full Text Available We discuss the inverse free electron laser (IFEL scheme as a compact high gradient accelerator solution for driving advanced light sources such as a soft x-ray free electron laser amplifier or an inverse Compton scattering based gamma-ray source. In particular, we present a series of new developments aimed at improving the design of future IFEL accelerators. These include a new procedure to optimize the choice of the undulator tapering, a new concept for prebunching which greatly improves the fraction of trapped particles and the final energy spread, and a self-consistent study of beam loading effects which leads to an energy-efficient high laser-to-beam power conversion.

  1. Seeded free-electron and inverse free-electron laser techniques for radiation amplification and electron microbunching in the terahertz range

    Directory of Open Access Journals (Sweden)

    C. Sung

    2006-12-01

    Full Text Available A comprehensive analysis is presented that describes amplification of a seed THz pulse in a single-pass free-electron laser (FEL driven by a photoinjector. The dynamics of the radiation pulse and the modulated electron beam are modeled using the time-dependent FEL code, GENESIS 1.3. A 10-ps (FWHM electron beam with a peak current of 50–100 A allows amplification of a ∼1  kW seed pulse in the frequency range 0.5–3 THz up to 10–100 MW power in a relatively compact 2-m long planar undulator. The electron beam driving the FEL is strongly modulated, with some inhomogeneity due to the slippage effect. It is shown that THz microbunching of the electron beam is homogeneous over the entire electron pulse when saturated FEL amplification is utilized at the very entrance of an undulator. This requires seeding of a 30-cm long undulator buncher with a 1–3 MW of pump power with radiation at the resonant frequency. A narrow-band seed pulse in the THz range needed for these experiments can be generated by frequency mixing of CO_{2} laser lines in a GaAs nonlinear crystal. Two schemes for producing MW power pulses in seeded FELs are considered in some detail for the beam parameters achievable at the Neptune Laboratory at UCLA: the first uses a waveguide to transport radiation in the 0.5–3 THz range through a 2-m long FEL amplifier and the second employs high-gain third harmonic generation using the FEL process at 3–9 THz.

  2. A novel cofactor-binding mode in bacterial IMP dehydrogenases explains inhibitor selectivity.

    Science.gov (United States)

    Makowska-Grzyska, Magdalena; Kim, Youngchang; Maltseva, Natalia; Osipiuk, Jerzy; Gu, Minyi; Zhang, Minjia; Mandapati, Kavitha; Gollapalli, Deviprasad R; Gorla, Suresh Kumar; Hedstrom, Lizbeth; Joachimiak, Andrzej

    2015-02-27

    The steadily rising frequency of emerging diseases and antibiotic resistance creates an urgent need for new drugs and targets. Inosine 5'-monophosphate dehydrogenase (IMP dehydrogenase or IMPDH) is a promising target for the development of new antimicrobial agents. IMPDH catalyzes the oxidation of IMP to XMP with the concomitant reduction of NAD(+), which is the pivotal step in the biosynthesis of guanine nucleotides. Potent inhibitors of bacterial IMPDHs have been identified that bind in a structurally distinct pocket that is absent in eukaryotic IMPDHs. The physiological role of this pocket was not understood. Here, we report the structures of complexes with different classes of inhibitors of Bacillus anthracis, Campylobacter jejuni, and Clostridium perfringens IMPDHs. These structures in combination with inhibition studies provide important insights into the interactions that modulate selectivity and potency. We also present two structures of the Vibrio cholerae IMPDH in complex with IMP/NAD(+) and XMP/NAD(+). In both structures, the cofactor assumes a dramatically different conformation than reported previously for eukaryotic IMPDHs and other dehydrogenases, with the major change observed for the position of the NAD(+) adenosine moiety. More importantly, this new NAD(+)-binding site involves the same pocket that is utilized by the inhibitors. Thus, the bacterial IMPDH-specific NAD(+)-binding mode helps to rationalize the conformation adopted by several classes of prokaryotic IMPDH inhibitors. These findings offer a potential strategy for further ligand optimization. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  3. A Novel Cofactor-binding Mode in Bacterial IMP Dehydrogenases Explains Inhibitor Selectivity*

    Science.gov (United States)

    Makowska-Grzyska, Magdalena; Kim, Youngchang; Maltseva, Natalia; Osipiuk, Jerzy; Gu, Minyi; Zhang, Minjia; Mandapati, Kavitha; Gollapalli, Deviprasad R.; Gorla, Suresh Kumar; Hedstrom, Lizbeth; Joachimiak, Andrzej

    2015-01-01

    The steadily rising frequency of emerging diseases and antibiotic resistance creates an urgent need for new drugs and targets. Inosine 5′-monophosphate dehydrogenase (IMP dehydrogenase or IMPDH) is a promising target for the development of new antimicrobial agents. IMPDH catalyzes the oxidation of IMP to XMP with the concomitant reduction of NAD+, which is the pivotal step in the biosynthesis of guanine nucleotides. Potent inhibitors of bacterial IMPDHs have been identified that bind in a structurally distinct pocket that is absent in eukaryotic IMPDHs. The physiological role of this pocket was not understood. Here, we report the structures of complexes with different classes of inhibitors of Bacillus anthracis, Campylobacter jejuni, and Clostridium perfringens IMPDHs. These structures in combination with inhibition studies provide important insights into the interactions that modulate selectivity and potency. We also present two structures of the Vibrio cholerae IMPDH in complex with IMP/NAD+ and XMP/NAD+. In both structures, the cofactor assumes a dramatically different conformation than reported previously for eukaryotic IMPDHs and other dehydrogenases, with the major change observed for the position of the NAD+ adenosine moiety. More importantly, this new NAD+-binding site involves the same pocket that is utilized by the inhibitors. Thus, the bacterial IMPDH-specific NAD+-binding mode helps to rationalize the conformation adopted by several classes of prokaryotic IMPDH inhibitors. These findings offer a potential strategy for further ligand optimization. PMID:25572472

  4. Direct comparison study between FDG-PET and IMP-SPECT for diagnosing Alzheimer's disease using 3D-SSP analysis in the same patients

    International Nuclear Information System (INIS)

    Nihashi, Takashi; Hayasaka, Kazumasa; Yatsuya, Hiroshi

    2007-01-01

    The purpose of this study was to evaluate and compare the diagnostic ability of 2-[ 18 F]-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) and N-isopropyl-p- 123 I iodoamphetamine single photon emission computed tomography (IMP-SPECT) using three-dimensional stereotactic surface projections (3D-SSP) in patients with moderate Alzheimer's disease (AD). FDG-PET and IMP-SPECT were performed within 3 months in 14 patients with probable moderate AD. Z-score maps of FDG-PET and IMP-SPECT images of a patient were obtained by comparison with data obtained from control subjects. Four expert physicians evaluated and graded the glucose hypometabolism and regional cerebral blood flow (rCBF), focusing in particular on the posterior cingulate gyri/precunei and parietotemporal regions, and determined the reliability for AD. Receiver operating characteristic (ROC) curves were applied to the results for clarification. To evaluate the correlation between two modalities, the regions of interest (ROIs) were set in the posterior cingulate gyri/precunei and parietotemporal region on 3D-SSP images, and mean Z-values were calculated. No significant difference was observed in the area under the ROC curve (AUC) between FDG-PET and IMP-SPECT images (FDG-PET 0.95, IMP-SPECT 0.94). However, a significant difference (P<0.05) was observed in the AUC for the posterior cingulate gyri/precuneus (FDG-PET 0.94, IMP-SPECT 0.81). The sensitivity and specificity of each modality were 86%, and 97% for FDG-PET and 70% and 100% for IMP-SPECT. We could find no significant difference between FDG-PET and IMP-SPECT in terms of diagnosing moderate AD using 3D-SSP. There was a high correlation between the two modalities in the parietotemporal region (Spearman's r=0.82, P<0.001). The correlation in the posterior cingulate gyri/precunei region was lower than that in the parietotemporal region (Spearman's r=0.63, P<0.016). (author)

  5. Applications for Energy Recovering Free Electron Lasers

    Energy Technology Data Exchange (ETDEWEB)

    George Neil

    2007-08-01

    The availability of high-power, high-brilliance sources of tunable photons from energy-recovered Free Electron Lasers is opening up whole new fields of application of accelerators in industry. This talk will review some of the ideas that are already being put into production, and some of the newer ideas that are still under development.

  6. Radial evolution of the solar wind from IMP 8 to Voyager 2

    Science.gov (United States)

    Richardson, John D.; Paularena, Karolen I.; Lazarus, Alan J.; Belcher, John W.

    1995-01-01

    Voyager 2 and Interplanetary Monitoring Platform (IMP) 8 data from 1977 through 1994 are presented and compared. Radial velocity and temperature structures remain intact over the distance from 1 to 43 AU, but density structures do not. Temperature and velocity changes are correlated and nearly in phase at 1 AU, but in the outer heliosphere temperature changes lead velocity changes by tens of days. Solar cycle variations are detected by both spacecraft, with minima in flux density and dynamic pressure near solar maxima. Differences between Voyager 2 and IMP 8 observations near the solar minimum in 1986-1987 are attributed to latitudinal gradients in solar wind properties. Solar rotation variations are often present even at 40 AU. The Voyager 2 temperature profile is best fit with a R(exp -0.49 +/- 0.01) decrease, much less steep than an adiabatic profile.

  7. A multi-frequency approach to free electron lasers driven by short electron bunches

    International Nuclear Information System (INIS)

    Piovella, Nicola

    1997-01-01

    A multi-frequency model for free electron lasers (FELs), based on the Fourier decomposition of the radiation field coupled with the beam electrons, is discussed. We show that the multi-frequency approach allows for an accurate description of the evolution of the radiation spectrum, also when the FEL is driven by short electron bunches, of arbitrary longitudinal profile. We derive from the multi-frequency model, by averaging over one radiation period, the usual FEL equations modelling the slippage between radiation and particles and describing the super-radiant regime in high-gain FELs. As an example of application of the multi-frequency model, we discuss the coherent spontaneous emission (CSE) from short electron bunches

  8. Inverse free-electron laser accelerator development

    International Nuclear Information System (INIS)

    Fisher, A.; Gallardo, J.; Steenbergen, A. van; Sandweiss, J.; Fang, J.M.

    1994-06-01

    The study of the Inverse Free-Electron Laser, as a potential mode of electron acceleration, has been pursued at Brookhaven National Laboratory for a number of years. More recent studies focused on the development of a low energy (few GeV), high gradient, multistage linear accelerator. The authors are presently designing a short accelerator module which will make use of the 50 MeV linac beam and high power (2 x 10 11 W) CO 2 laser beam of the Accelerator Test Facility (ATF) at the Center for Accelerator Physics (CAP), Brookhaven National Laboratory. These elements will be used in conjunction with a fast excitation (300 μsec pulse duration) variable period wiggler, to carry out an accelerator demonstration stage experiment

  9. Electron beam halo monitor for a compact x-ray free-electron laser

    Directory of Open Access Journals (Sweden)

    Hideki Aoyagi

    2013-03-01

    Full Text Available An electron beam halo monitor using diamond-based detectors, which are operated in the ionization mode, has been developed for the SPring-8 Angstrom compact free-electron laser (SACLA to protect its undulator magnets from radiation damage. Diamond-based detectors are inserted in a beam duct to measure the intensity of the beam halo directly. To suppress the degradation of the electron beam due to the installation of the beam halo monitor, rf fingers with aluminum windows are newly employed. We evaluated the effect of radiation from the Al windows on the output signal both experimentally and by simulation. The operational results of the beam halo monitor employed in SACLA are presented.

  10. Event reconstruction for the RICH prototype beamtest data 2012 and 2014

    Energy Technology Data Exchange (ETDEWEB)

    Lebedev, Semen [II. Physikalisches Institut, JLU Giessen (Germany); Collaboration: CBM-Collaboration

    2016-07-01

    The Compressed Baryonic Matter (CBM) experiment at the future FAIR facility will investigate the QCD phase diagram at high net baryon densities and moderate temperatures in A+A collisions from 2-11 AGeV (SIS100). Electron identification in CBM will be performed by a Ring Imaging Cherenkov (RICH) detector and Transition Radiation Detectors (TRD). A real size prototype of the RICH detector was tested together with other CBM prototypes (TRD, TOF) at the CERN PS/T9 beam line in 2012 and 2014. In 2014 for the first time the data format used the FLESnet protocol from CBM delivering free streaming data. The analysis was fully performed within the CBMROOT framework. In this contribution the event reconstruction methods which were used for obtained data are discussed. Rings were reconstructed using an algorithm based on the Hough Transform method and their parameters were derived with high accuracy by circle and ellipse fitting procedures. Results of the application of the presented algorithms are also presented.

  11. Development of a high power free-electron laser

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Min; Lee, Byung Chul; Kim, Sun Kook; Jung, Yung Wook; Cho, Sung Oh [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-01-01

    A millimeter-wave free electron laser (FEL) driven by a recirculating electrostatic accelerator has been developed. The wavelength of the FEL is tunable in the range of 3 - 12 mm by tuning the energy of the electron beam. The output power is estimated to be 1 kW. The electrostatic accelerator is composed of high-current electron gun, acceleration tube, high-voltage generator, high-voltage terminal, deceleration tube, electron collator, and vacuum pumps. Two types of LaB{sub 6}-based thermionic electron guns (triode gun and diode gun) and their power supplies have been developed. The voltage of the guns is 30 kV and the output current is - 2 A. A beam-focusing planar undulator and a permanent-magnet helical undulator have been developed and 3D trajectories of electron beam in the undulators have been calculated to find optimal input condition of electron beam. 135 figs, 15 pix, 17 tabs, 98 refs. (Author).

  12. Development of a high power free-electron laser

    International Nuclear Information System (INIS)

    Lee, Jong Min; Lee, Byung Chul; Kim, Sun Kook; Jung, Yung Wook; Cho, Sung Oh

    1995-01-01

    A millimeter-wave free electron laser (FEL) driven by a recirculating electrostatic accelerator has been developed. The wavelength of the FEL is tunable in the range of 3 - 12 mm by tuning the energy of the electron beam. The output power is estimated to be 1 kW. The electrostatic accelerator is composed of high-current electron gun, acceleration tube, high-voltage generator, high-voltage terminal, deceleration tube, electron collator, and vacuum pumps. Two types of LaB 6 -based thermionic electron guns (triode gun and diode gun) and their power supplies have been developed. The voltage of the guns is 30 kV and the output current is - 2 A. A beam-focusing planar undulator and a permanent-magnet helical undulator have been developed and 3D trajectories of electron beam in the undulators have been calculated to find optimal input condition of electron beam. 135 figs, 15 pix, 17 tabs, 98 refs. (Author)

  13. Microwave free-electron laser applications for electron cyclotron heating of plasmas

    International Nuclear Information System (INIS)

    Thomassen, K.I.

    1990-01-01

    Millimeter wave power may be the ideal source of heat for a plasma, but advances in technology are needed to meet requirements of next generation fusion devices. Free electron lasers (FEL) are one candidate for such sources, and this paper reviews the progress, issues of physics and technology, and potential benefits for fusion from these devices. 15 refs., 13 figs

  14. Free electron laser amplifier driven by an induction linac

    International Nuclear Information System (INIS)

    Neil, V.K.

    1986-01-01

    This paper discusses the use of a free-electron laser amplifier as a means of converting the kinetic energy of an electron beam into coherent radiation. In particular, the use of an induction linear accelerator is discussed. The motion of the elections in the tapered and untapered wiggler magnets is discussed as well as the beam emittance, and the radiation fields involved

  15. A Prototype Ionization Profile Monitor for RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Connolly, R. [Brookhaven National Lab. (BNL), Upton, NY (United States); Cameron, P. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ryan, W. [Brookhaven National Lab. (BNL), Upton, NY (United States); Shea, T. [Brookhaven National Lab. (BNL), Upton, NY (United States); Sikora, R. [Brookhaven National Lab. (BNL), Upton, NY (United States); Tsoupas, N. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    1997-03-17

    The Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Lab will accelerate and store beams of ions ranging from protons to gold nuclei. Transverse beam profiles will be obtained by measuring the distribution of free electrons formed by beam ionization of the residual gas. The electrons are swept from the beamline by a transverse electric field, amplified by a microchannel plate (MCP), and collected on a circuit board with strip anodes oriented parallel to the beam axis. A uniform magnetic field,parallel to the sweep electric field, counters the defocusing effects of space charge and recoil momentum. A single-plane prototype ionization profile montor (IPM) was installed near the end of the AGS-to-RHIC transfer line (ATR) and tested during the sextant commissioning rung. It measured vertical profiles of single bunches of Au nuclei with intensities of 0.6-1.0 x 108 particles. These profiles are compared to profiles on a fluorescent screen (WF3) located 2m downstream from the IPM. This paper describes the detector and gives results from the beam test.

  16. Two-stage free electron laser research

    Science.gov (United States)

    Segall, S. B.

    1984-10-01

    KMS Fusion, Inc. began studying the feasibility of two-stage free electron lasers for the Office of Naval Research in June, 1980. At that time, the two-stage FEL was only a concept that had been proposed by Luis Elias. The range of parameters over which such a laser could be successfully operated, attainable power output, and constraints on laser operation were not known. The primary reason for supporting this research at that time was that it had the potential for producing short-wavelength radiation using a relatively low voltage electron beam. One advantage of a low-voltage two-stage FEL would be that shielding requirements would be greatly reduced compared with single-stage short-wavelength FEL's. If the electron energy were kept below about 10 MeV, X-rays, generated by electrons striking the beam line wall, would not excite neutron resonance in atomic nuclei. These resonances cause the emission of neutrons with subsequent induced radioactivity. Therefore, above about 10 MeV, a meter or more of concrete shielding is required for the system, whereas below 10 MeV, a few millimeters of lead would be adequate.

  17. Extreme UV harmonic production by free-electron generators of coherent radiation

    International Nuclear Information System (INIS)

    Ortega, J.M.

    1986-01-01

    The bunching phenomenon is the basic process occurring in a free-electron generator of coherent generation such as the Klystron in the mm-wave-length range or the free-electron laser (FEL) in the optical region. During interaction with the incident electromagnetic wave the electrons are progressively gathered into small packets separated by a length equal to its wavelength λ/sub L/. Once the electrons are bunched there is a given phase relationship between them and the field of any wave which wavelength is an harmonic of λ/sub L/. This is the source of the gain (electrons decelerated by the field) or of the absorption (electrons accelerated by the laser) mechanisms. In the FEL case the electrons are passing through an undulator (spatially varying periodic magnetic field). Since one uses high-energy electrons (E≅100-1000 MeV) they emit synchrotron radiation called in this case undulator radiation or spontaneous emission. This radiation coexists with the stimulated emission giving rise to the gain mechanism and to the FEL oscillation. When the electrons are bunched the spontaneous emission becomes coherent at the wavelength harmonic of λ/sub L/, and there is an increase in the emission intensity which ideally would be N/sub e/. (Number of electrons is typically ≅10/sup 10/.) Thus bursts of photons are emitted at frequencies harmonic of an incident wave which may be an external laser or the FEL itself. This is likely to extend the spectral range of the free-electron generation of coherent radiation toward the extreme UV λ<1000A). The advantages and limitations of the various solutions (linear or circular accelerator, FEL, or external laser) are discussed. The authors summarize the various experimental results obtained to date and the prospects for the synchrotron radiation dedicated ring super-ACO presently under construction at LURE at Orsay

  18. Rigorous bounds on the free energy of electron-phonon models

    NARCIS (Netherlands)

    Raedt, Hans De; Michielsen, Kristel

    1997-01-01

    We present a collection of rigorous upper and lower bounds to the free energy of electron-phonon models with linear electron-phonon interaction. These bounds are used to compare different variational approaches. It is shown rigorously that the ground states corresponding to the sharpest bounds do

  19. Crystallographic data processing for free-electron laser sources

    International Nuclear Information System (INIS)

    White, Thomas A.; Barty, Anton; Stellato, Francesco; Holton, James M.; Kirian, Richard A.; Zatsepin, Nadia A.; Chapman, Henry N.

    2013-01-01

    A processing pipeline for diffraction data acquired using the ‘serial crystallography’ methodology with a free-electron laser source is described with reference to the crystallographic analysis suite CrystFEL and the pre-processing program Cheetah. A processing pipeline for diffraction data acquired using the ‘serial crystallography’ methodology with a free-electron laser source is described with reference to the crystallographic analysis suite CrystFEL and the pre-processing program Cheetah. A detailed analysis of the nature and impact of indexing ambiguities is presented. Simulations of the Monte Carlo integration scheme, which accounts for the partially recorded nature of the diffraction intensities, are presented and show that the integration of partial reflections could be made to converge more quickly if the bandwidth of the X-rays were to be increased by a small amount or if a slight convergence angle were introduced into the incident beam

  20. Crystallographic data processing for free-electron laser sources

    Energy Technology Data Exchange (ETDEWEB)

    White, Thomas A., E-mail: taw@physics.org; Barty, Anton; Stellato, Francesco [DESY, Notkestrasse 85, 22607 Hamburg (Germany); Holton, James M. [University of California, San Francisco, CA 94158 (United States); Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Kirian, Richard A. [DESY, Notkestrasse 85, 22607 Hamburg (Germany); Arizona State University, Tempe, AZ 85287 (United States); Zatsepin, Nadia A. [Arizona State University, Tempe, AZ 85287 (United States); Chapman, Henry N. [DESY, Notkestrasse 85, 22607 Hamburg (Germany); University of Hamburg, Luruper Chaussee 149, 22761 Hamburg (Germany)

    2013-07-01

    A processing pipeline for diffraction data acquired using the ‘serial crystallography’ methodology with a free-electron laser source is described with reference to the crystallographic analysis suite CrystFEL and the pre-processing program Cheetah. A processing pipeline for diffraction data acquired using the ‘serial crystallography’ methodology with a free-electron laser source is described with reference to the crystallographic analysis suite CrystFEL and the pre-processing program Cheetah. A detailed analysis of the nature and impact of indexing ambiguities is presented. Simulations of the Monte Carlo integration scheme, which accounts for the partially recorded nature of the diffraction intensities, are presented and show that the integration of partial reflections could be made to converge more quickly if the bandwidth of the X-rays were to be increased by a small amount or if a slight convergence angle were introduced into the incident beam.

  1. Embryonic expression of Drosophila IMP in the developing CNS and PNS

    DEFF Research Database (Denmark)

    Adolph, Sidsel Kramshøj; Delotto, Robert; Nielsen, Finn Cilius

    2008-01-01

    embryogenesis. In the cellular blastoderm, immunoreactivity was seen in the entire cell-layer, where it was localized apically to the nucleus, and in the pole cells. Later, the GFP-dIMP fusion protein appeared in the developing central nervous system, both in the brain and in the ventral nerve cord...

  2. Charged beam dynamics, particle accelerators and free electron lasers

    CERN Document Server

    Dattoli, Giuseppe; Sabia, Elio; Artioli, Marcello

    2017-01-01

    Charged Beam Dynamics, Particle Accelerators and Free Electron Lasers summarises different topics in the field of accelerators and of Free Electron Laser (FEL) devices. It is intended as a reference manual for the different aspects of FEL devices, explaining how to design both a FEL device and the accelerator providing the driving beam. It covers both theoretical and experimental aspects, allowing researchers to attempt a first design of a FEL device in different operating conditions. It provides an analysis of what is already available, what is needed, and what the challenges are to determine new progress in this field. All chapters contain complements and exercises that are designed in such a way that the reader will gradually acquire self-confidence with the matter treated in the book.

  3. Applications of Free Electron Lasers in Biology and Medicine

    International Nuclear Information System (INIS)

    Pelka, J.B.; Tybor, K.R.; Nietubyc, R.; Wrochna, G.

    2010-01-01

    The advent of free electron lasers opens up new opportunities to probe the dynamics of ultrafast processes and the structure of matter with unprecedented spatial and temporal resolution. New methods inaccessible with other known types of radiation sources can be developed, resulting in a breakthrough in deep understanding the fundamentals of life as well as in numerous medical and biological applications. In the present work the properties of free electron laser radiation that make the sources excellent for probing biological matter at an arbitrary wavelength, in a wide range of intensities and pulse durations are briefly discussed. A number of biophysical and biomedical applications of the new sources, currently considered among the most promising in the field, are presented. (author)

  4. Electron mean free path from angle-dependent photoelectron spectroscopy of aerosol particles

    Energy Technology Data Exchange (ETDEWEB)

    Goldmann, Maximilian; Miguel-Sánchez, Javier; West, Adam H. C.; Yoder, Bruce L.; Signorell, Ruth, E-mail: rsignorell@ethz.ch [Laboratory of Physical Chemistry, ETH Zürich, Vladimir-Prelog-Weg 2, 8093 Zürich (Switzerland)

    2015-06-14

    We propose angle-resolved photoelectron spectroscopy of aerosol particles as an alternative way to determine the electron mean free path of low energy electrons in solid and liquid materials. The mean free path is obtained from fits of simulated photoemission images to experimental ones over a broad range of different aerosol particle sizes. The principal advantage of the aerosol approach is twofold. First, aerosol photoemission studies can be performed for many different materials, including liquids. Second, the size-dependent anisotropy of the photoelectrons can be exploited in addition to size-dependent changes in their kinetic energy. These finite size effects depend in different ways on the mean free path and thus provide more information on the mean free path than corresponding liquid jet, thin film, or bulk data. The present contribution is a proof of principle employing a simple model for the photoemission of electrons and preliminary experimental data for potassium chloride aerosol particles.

  5. Development of 3000 m Subsea Blowout Preventer Experimental Prototype

    Science.gov (United States)

    Cai, Baoping; Liu, Yonghong; Huang, Zhiqian; Ma, Yunpeng; Zhao, Yubin

    2017-12-01

    A subsea blowout preventer experimental prototype is developed to meet the requirement of training operators, and the prototype consists of hydraulic control system, electronic control system and small-sized blowout preventer stack. Both the hydraulic control system and the electronic system are dual-mode redundant systems. Each system works independently and is switchable when there are any malfunctions. And it significantly improves the operation reliability of the equipment.

  6. 7. Seminar of the IIE-IMP-ININ on technological specialities. Topic 8: Analytical Chemistry; 7. Seminario IIE-IMP-ININ sobre especialidades tecnologicas. Mesa 8: Quimica Analitica

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    With the purpose to give continuity to the exchange of experiences and to impel the development of common specialties among IIE-ININ-IMP, the VII Seminary was held in Mexico City on September 7, 1994. In the event were present 163 researchers of the three participant Institutions as well as representative persons of invited institutions. The objective of this Seminary was to relate the researchers of a common branch, with the idea that the specialists made an exchange of experiences, in order to establish cooperation routes. The event was arranged in 11 working tables, with a total of 111 papers: 43 of these papers were from IIE, 42 from IMP, 22 from ININ and 4 from invited entities. During the Seminary, the 11 working tables has sessions simultaneously, and each one of the papers were discussed at the time that possible future cooperating inter institutional actions were examined. The conclusions of the Seminary were exposed in a plenary session, in the presence of the directing boards of the three participant Institutions.

  7. The electron accelerator for FELIX [Free Electron Laser for Infrared eXperiments

    International Nuclear Information System (INIS)

    Amersfoort, P.W. van; Geer, C.A.J. van der; Meer, A.F.G. van der; Bruinsma, P.J.T.; Hoekstra, R.; Kroes, F.B.; Luyckx, G.; Noomen, J.G.; Poole, M.W.; Saxon, G.

    1989-01-01

    The authors discuss the design of the electron accelerator for the Free Electron Laser for Infrared eXperiments (FELIX), which is meant to provide the Dutch science community with a rapidly tunable source of infrared radiation. The first stage of the project will (at least) cover the wavelength range between 8 and 80 μm. The accelerator consists of a triode with a grid modulated at 1 GHz, a 3.8-MeV buncher, and two travelling-wave S-band linac structures, with which 70-A, 3-ps bunches are accelerated to an energy between 15 and 4-5 MeV. The system has been designed to minimize the energy spread in the electron beam. 8 refs., 2 figs., 1 tab

  8. Comment on 'Magnetosheath burst of predominantly medium nuclei observed with Imp 8 on February 16, 1974' by T. P. Armstrong, S. M. Krimigis, and R. P. Lepping

    International Nuclear Information System (INIS)

    Hovestadt, D.

    1980-01-01

    Armstrong et al. (1978) report the observation of a unique series of charged particle bursts with an unusually high content of Z>2 particles and a high degree of collimation from the direction of the sun. These bursts were observed only with their CPME (charged particle measurement experiment) instrument on Imp 8, while not with the CPME on Imp 7. No indication has been seen for heavy ion bursts comparable in intensity to those reported by Armstrong et al. (1978) with the ULET (ultralow energy telescope) instrument of the University of Maryland/Max-Planck-Institut experiment on Imp 8 at the same time. It is noted that the ULET counting rates observed on Imp 8 are fully compatible with the CPME rates observed on the Imp 7 spacecraft. We conclude that the CPME and the ULET data from IMP 8 during these periods do not agree, and this casts doubt on the correctness of the CPME results for these special events

  9. Role of 123I-IMP SPET in the early diagnosis of borderline chronic hydrocephalus after aneurysmal subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Ohkuma, Hiroki; Tanaka, Masahiko; Suzuki, Shigeharu; Kondoh, Izumi

    2000-01-01

    Chronic hydrocephalus after aneurysmal subarachnoid haemorrhage (SAH) is easily diagnosed in most cases. However, the diagnosis is sometimes difficult in borderline cases, in which (a) pathognomonic clinical deterioration due to hydrocephalus is masked by the neurological deficits caused in the acute stage of SAH and (b) ventricular enlargement is not so marked on CT scan. The purpose of this study was to investigate whether or not iodine-123 labelled N-isopropyl-p-iodoamphetamine ( 123 I-IMP) single-photon emission tomography (SPET) is of value for the early diagnosis of borderline chronic hydrocephalus after SAH. Fifteen patients who met the criteria of borderline chronic hydrocephalus were selected for the study, and underwent a shunt operation. The patients were divided into a shunt-effective group and a shunt-ineffective group according to neurological improvement after the shunt operation. 123 I-IMP SPET was performed in the acute stage of SAH, within 1 week before the shunt operation, and 2 weeks after the shunt operation. Regional cerebral blood flow was estimated by the 123 I-IMP autoradiographic method. Pre-shunting periventricular low-perfusion areas showed statistically significant differences between the two groups (P 123 I-IMP SPET can be used for both the early diagnosis of borderline chronic hydrocephalus after SAH and the prediction of shunt effectiveness. (orig.)

  10. Progress toward the Wisconsin Free Electron Laser

    International Nuclear Information System (INIS)

    Bisognano, Joseph; Bosch, R.A.; Eisert, D.; Fisher, M.V.; Green, M.A.; Jacobs, K.; Kleman, K.J.; Kulpin, J.; Rogers, G.C.; Lawler, J.E.; Yavuz, D.; Legg, R.

    2011-01-01

    The University of Wisconsin-Madison/Synchrotron Radiation Center is advancing its design for a seeded VUV/soft X-ray Free Electron Laser facility called WiFEL. To support this vision of an ultimate light source, we are pursuing a program of strategic R and D addressing several crucial elements. This includes development of a high repetition rate, VHF superconducting RF electron gun, R and D on photocathode materials by ARPES studies, and evaluation of FEL facility architectures (e.g., recirculation, compressor scenarios, CSR dechirping, undulator technologies) with the specific goal of cost containment. Studies of high harmonic generation for laser seeding are also planned.

  11. The experimental electron mean-free-path in Si under typical (S)TEM conditions

    International Nuclear Information System (INIS)

    Potapov, P.L.

    2014-01-01

    The electron mean-free-path in Si was measured by EELS using the test structure with the certified dimensions as a calibration standard. In a good agreement with the previous CBED measurements, the mean-free-path is 150 nm for 200 keV and 179 nm for 300 keV energy of primary electrons at large collection angles. These values are accurately predicted by the model of Iakoubovskii et al. while the model of Malis et al. incorporated in common microscopy software underestimates the mean-free-path by 15% at least. Correspondingly, the thickness of TEM samples reported in many studies of the Si-based materials last decades might be noticeably underestimated. - Highlights: • The electron inelastic mean-free-path in Si is measured for the typical (S)TEM conditions. • These reference values allow for accurate determination of the lamella thickness by EELS. • The theoretical model by Malis et al. underestimates the mean-free-path values

  12. A new graphic method for evaluation of distribution volume on N-isopropyl-p-[[sup 123]I]iodoamphetamine (IMP) SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Odano, Ikuo; Takahashi, Naoya; Ohtaki, Hiroh; Noguchi, Eikichi; Hatano, Masayoshi; Yamasaki, Yoshihiro; Nishihara, Mamiko (Niigata Univ. (Japan). School of Medicine); Ohkubo, Masaki; Yokoi, Takashi

    1993-10-01

    We developed a new graphic method using N-isopropyl-p-[[sup 123]I]iodoamphetamine (IMP) and SPECT of the brain, the graph on which all three parameters, cerebral blood flow, distribution volume (V[sub d]) and delayed count to early count ratio (Delayed/Early ratio), were able to be evaluated simultaneously. The kinetics of [sup 123]I-IMP in the brain was analyzed by a 2-compartment model, and a standard input function was prepared by averaging the time activity curves of [sup 123]I-IMP in arterial blood on 6 patients with small cerebral infarction etc. including 2 normal controls. Being applied this method to the differential diagnosis between Parkinson's disease and progressive supranuclear palsy, we were able to differentiate both with a glance, because the distribution volume of the frontal lobe significantly decreased in Parkinson's disease (Mean[+-]SD; 26[+-]6 ml/g). This method was clinically useful. We think that the distribution volume of [sup 123]I-IMP may reflect its retention mechanism in the brain, and the values are related to amine, especially to dopamine receptors and its metabolism. (author).

  13. EUSO-TA prototype telescope

    Energy Technology Data Exchange (ETDEWEB)

    Bisconti, Francesca, E-mail: francesca.bisconti@kit.edu

    2016-07-11

    EUSO-TA is one of the prototypes developed for the JEM-EUSO project, a space-based large field-of-view telescope to observe the fluorescence light emitted by cosmic ray air showers in the atmosphere. EUSO-TA is a ground-based prototype located at the Telescope Array (TA) site in Utah, USA, where an Electron Light Source and a Central Laser Facility are installed. The purpose of the EUSO-TA project is to calibrate the prototype with the TA fluorescence detector in presence of well-known light sources and cosmic ray air showers. In 2015, the detector started the first measurements and tests using the mentioned light sources have been performed successfully. A first cosmic ray candidate has been observed, as well as stars of different magnitude and color index. Since Silicon Photo-Multipliers (SiPMs) are very promising for fluorescence telescopes of next generation, they are under consideration for the realization of a new prototype of EUSO Photo Detector Module (PDM). The response of this sensor type is under investigation through simulations and laboratory experimentation.

  14. EUSO-TA prototype telescope

    Science.gov (United States)

    Bisconti, Francesca; JEM-EUSO Collaboration

    2016-07-01

    EUSO-TA is one of the prototypes developed for the JEM-EUSO project, a space-based large field-of-view telescope to observe the fluorescence light emitted by cosmic ray air showers in the atmosphere. EUSO-TA is a ground-based prototype located at the Telescope Array (TA) site in Utah, USA, where an Electron Light Source and a Central Laser Facility are installed. The purpose of the EUSO-TA project is to calibrate the prototype with the TA fluorescence detector in presence of well-known light sources and cosmic ray air showers. In 2015, the detector started the first measurements and tests using the mentioned light sources have been performed successfully. A first cosmic ray candidate has been observed, as well as stars of different magnitude and color index. Since Silicon Photo-Multipliers (SiPMs) are very promising for fluorescence telescopes of next generation, they are under consideration for the realization of a new prototype of EUSO Photo Detector Module (PDM). The response of this sensor type is under investigation through simulations and laboratory experimentation.

  15. Free electron laser on the ACO storage ring

    International Nuclear Information System (INIS)

    Elleaume, P.

    1984-06-01

    This dissertation presents the design and characteristics of a Free Electron Laser built on the electron storage ring ACO at Orsay. The weak optical gain available (approximately 0.1% per pass) necessitated the use of an optical klystron instead of an undulator and the use of mirror with extremely high reflectivity. The laser characteristics: spectra, micro and macro-temporal structures, transverse structure and power are presented. They are in very good agreement with a classical theory based on the Lorentz force and Maxwell equations [fr

  16. Three-dimensional simulations of free-electron laser physics

    International Nuclear Information System (INIS)

    McVey, B.D.

    1985-09-01

    A computer code has been developed to simulate three-dimensional free-electron laser physics. A mathematical formulation of the FEL equations is presented, and the numerical solution of the problem is described. Sample results from the computer code are discussed. 23 refs., 6 figs., 2 tabs

  17. Influência da Impedância e Relutância em Recursos Eletroterapêuticos Utilizados em Tratamentos Fisioterapêuticos

    Directory of Open Access Journals (Sweden)

    Patrik Nepomuceno

    2018-02-01

    Full Text Available A eletroterapia consiste no tratamento através de correntes elétricas, ocasionando alterações fisiológicas. Dentro desta terapêutica temos os conceitos de impedância e relutância, temas importantes que devem ser conhecimento do fisioterapeuta. Objetivo: Analisar em dados literários aspectos relevantes à impedância e relutância de uma corrente elétrica nos recursos terapêuticos. Métodos: Foram buscados artigos científicos através de bases de dados, no período de março a junho de 2016. Utilizando palavras-chave como “impedância”, “relutância”, “eletroterapia” e “fisioterapia” e suas traduções para o inglês. Resultados: Nessa perspectiva encontraram-se sete artigos científicos que tratam sobre o assunto impedância, nesse período, e não foram encontrados artigos científicos sobre a relutância. Considerações finais: Diversos mecanismos estão relacionados à impedância da pele e sua redução está associada à sensação agradável relatada pelo paciente e também à efetividade do tratamento. Também é necessário ressaltar a importância para o profissional conhecer os assuntos tratados no presente estudo, pois assim ele poderá aplicar de maneira mais efetiva as correntes excitomotoras, gerando assim uma maior agilidade na terapêutica.

  18. A compact x-ray free electron laser

    International Nuclear Information System (INIS)

    Barletta, W.; Attac, M.; Cline, D.B.

    1988-01-01

    We present a design concept and simulation of the performance of a compact x-ray, free electron laser driven by ultra-high gradient rf-linacs. The accelerator design is based on recent advances in high gradient technology by a LLNL/SLAC/LBL collaboration and on the development of bright, high current electron sources by BNL and LANL. The GeV electron beams generated with such accelerators can be concerted to soft x-rays in the range from 2--10 nm by passage through short period, high fields strength wigglers as are being designed at Rocketdyne. Linear light sources of this type can produce trains of picosecond (or shorter) pulses of extremely high spectral brilliance suitable for flash holography of biological specimens in vivo and for studies of fast chemical reactions. 12 refs., 8 figs., 4 tabs

  19. Short Rayleigh length free electron lasers

    Directory of Open Access Journals (Sweden)

    W. B. Colson

    2006-03-01

    Full Text Available Conventional free electron laser (FEL oscillators minimize the optical mode volume around the electron beam in the undulator by making the resonator Rayleigh length about one third to one half of the undulator length. This maximizes gain and beam-mode coupling. In compact configurations of high-power infrared FELs or moderate power UV FELs, the resulting optical intensity can damage the resonator mirrors. To increase the spot size and thereby reduce the optical intensity at the mirrors below the damage threshold, a shorter Rayleigh length can be used, but the FEL interaction is significantly altered. We model this interaction using a coordinate system that expands with the rapidly diffracting optical mode from the ends of the undulator to the mirrors. Simulations show that the interaction of the strongly focused optical mode with a narrow electron beam inside the undulator distorts the optical wave front so it is no longer in the fundamental Gaussian mode. The simulations are used to study how mode distortion affects the single-pass gain in weak fields, and the steady-state extraction in strong fields.

  20. Transient analysis of a bunched beam free electron laser

    International Nuclear Information System (INIS)

    Wang, J.M.; Yu, L.H.

    1985-01-01

    The problem of the bunched beam operation of a free electron laser was studied. Assuming the electron beam to be initially monoenergetic, the Maxwell-Vlasov equations describing the system reduce to a third order partial differential equation for the envelope of the emitted light. The Green's function corresponding to an arbitrary shape of the electron bunch, which describes the transient behavior of the system, is obtained. The Green's function was used to discuss the start up problem as well as the power output and the power specrum of a self-amplified spontaneous emission

  1. Chaotic behaviour and controlling chaos in free electron lasers

    International Nuclear Information System (INIS)

    Wang Wenjie; Chen Shigang; Du Xiangwan; Wang Guangrui

    1995-01-01

    Chaos in free electron lasers (FEL) is reviewed. Special attention has been paid to the chaotic behaviour of the electrons and the laser field. The problem of controlling and utilizing chaotic motion of the electrons and the laser field has also been discussed. In order to find out the rules of instability and chaos in FEL, some typical methods of the chaotic theory are used. These methods include making the Poincare surface of section, drawing the phase space diagrams of the electron orbits, calculating the Liapunov exponents, and computing the power spectrum, etc. Finally, some problems in FEL research are discussed (103 refs., 54 figs.)

  2. Free electron lasers on superconducting linac

    International Nuclear Information System (INIS)

    Lapierrre, Y.

    1986-01-01

    Analysing the results of several Free Electron Laser experiments, we show that the best accelerator should be a superconducting linear accelerator: it can provide a c.w. high quality beam (energy spread and emittance). The technology of RF superconductivity provide the opportunity to build such an accelerator. In this paper, we present the foreseen results one can expect from a FEL based on such a machine: - Average power > 1 Kw, - Total efficiency > 2.5%, - Tunability between 0.6 and 5 μm [fr

  3. Design, manufacturing and tests of first cryogen-free MgB2 prototype coils for offshore wind generators

    International Nuclear Information System (INIS)

    Sarmiento, G; Sanz, S; Pujana, A; Merino, J M; Apiñaniz, S; Marino, I; Iturbe, R; Nardelli, D

    2014-01-01

    Although renewable sector has started to take advantage of the offshore wind energy recently, the development is very intense. Turbines reliability, size, and cost are key aspects for the wind industry, especially in marine locations. A superconducting generator will allow a significant reduction in terms of weight and size, but cost and reliability are two aspects to deal with. MgB 2 wire is presented as one promising option to be used in superconducting coils for wind generators. This work shows the experimental results in first cryogen-free MgB 2 prototype coils, designed according to specific requirements of TECNALIA's wind generator concept.

  4. Hybrid circuit prototypes for the CMS Tracker upgrade front-end electronics

    International Nuclear Information System (INIS)

    Blanchot, G; Honma, A; Kovacs, M; Braga, D; Raymond, M

    2013-01-01

    New high-density interconnect hybrid circuits are under development for the CMS tracker modules at the HL-LHC. These hybrids will provide module connectivity between flip-chip front-end ASICs, strip sensors and a service board for the data transmission and powering. Rigid organic-based substrate prototypes and also a flexible hybrid design have been built, containing up to eight front-end flip chip ASICs. A description of the function of the hybrid circuit in the tracker, the first prototype designs, results of some electrical and mechanical properties from the prototypes, and examples of the integration of the hybrids into detector modules are presented

  5. Designed azurins show lower reorganization free energies for intraprotein electron transfer

    DEFF Research Database (Denmark)

    Farver, Ole; Marshall, Nicholas M; Wherland, Scot

    2013-01-01

    Low reorganization free energies are necessary for fast electron transfer (ET) reactions. Hence, rational design of redox proteins with lower reorganization free energies has been a long-standing challenge, promising to yield a deeper understanding of the underlying principles of ET reactivity...

  6. Direction-division multiplexed holographic free-electron-driven light sources

    Science.gov (United States)

    Clarke, Brendan P.; MacDonald, Kevin F.; Zheludev, Nikolay I.

    2018-01-01

    We report on a free-electron-driven light source with a controllable direction of emission. The source comprises a microscopic array of plasmonic surface-relief holographic domains, each tailored to direct electron-induced light emission at a selected wavelength into a collimated beam in a prescribed direction. The direction-division multiplexed source is tested by driving it with the 30 kV electron beam of a scanning electron microscope: light emission, at a wavelength of 800 nm in the present case, is switched among different output angles by micron-scale repositioning of the electron injection point among domains. Such sources, with directional switching/tuning possible at picosecond timescales, may be applied to field-emission and surface-conduction electron-emission display technologies, optical multiplexing, and charged-particle-beam position metrology.

  7. Development of superconducting acceleration cavity technology for free electron lasers

    International Nuclear Information System (INIS)

    Lee, Jong Min; Lee, Byung Cheol; Kim, Sun Kook; Jeong, Young Uk; Cho, Sung Oh

    2000-10-01

    As a result of the cooperative research between the KAERI and Peking University, the key technologies of superconducting acceleration cavity and photoelectron gun have been developed for the application to high power free electron lasers. A 1.5-GHz, 1-cell superconducting RF cavity has been designed and fabricated by using pure Nb sheets. The unloaded Q values of the fabricated superconducting cavity has been measured to be 2x10 9 at 2.5K, and 8x10 9 at 1.8K. The maximum acceleration gradient achieved was 12 MeV/m at 2.5K, and 20MV/m at 1.8 K. A cryostat for the 1-cell superconducting cavity has been designed. As a source of electron beam, a DC photocathode electron gun has been designed and fabricated, which is composed of a photocathode evaporation chamber and a 100-keV acceleration chamber. The efficiency of the Cs2Te photocathode is 3% nominally at room temperature, 10% at 290 deg C. The superconducting photoelectron gun system developed has been estimated to be a good source of high-brightness electron beam for high-power free electron lasers

  8. Development of superconducting acceleration cavity technology for free electron lasers

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Min; Lee, Byung Cheol; Kim, Sun Kook; Jeong, Young Uk; Cho, Sung Oh

    2000-10-01

    As a result of the cooperative research between the KAERI and Peking University, the key technologies of superconducting acceleration cavity and photoelectron gun have been developed for the application to high power free electron lasers. A 1.5-GHz, 1-cell superconducting RF cavity has been designed and fabricated by using pure Nb sheets. The unloaded Q values of the fabricated superconducting cavity has been measured to be 2x10{sup 9} at 2.5K, and 8x10{sup 9} at 1.8K. The maximum acceleration gradient achieved was 12 MeV/m at 2.5K, and 20MV/m at 1.8 K. A cryostat for the 1-cell superconducting cavity has been designed. As a source of electron beam, a DC photocathode electron gun has been designed and fabricated, which is composed of a photocathode evaporation chamber and a 100-keV acceleration chamber. The efficiency of the Cs2Te photocathode is 3% nominally at room temperature, 10% at 290 deg C. The superconducting photoelectron gun system developed has been estimated to be a good source of high-brightness electron beam for high-power free electron lasers.

  9. Atomic and Free Electrons in a Strong Light Field

    International Nuclear Information System (INIS)

    Fedorov, Mikhail V.

    1998-02-01

    This book presents and describes a series of unusual and striking strong-field phenomena concerning atoms and free electrons. Some of these phenomena are: multiphoton stimulated Bremsstrahlung, free-electron lasers, ave-packet physics, above-threshold ionization, and strong-field stabilization in Rydberg atoms. The theoretical foundations and causes of the phenomena are described in detail, with all the approximations and derivations discussed. All the known and relevant experiments are described oo, and their results are compared with those of the existing theoretical models. An extensive general theoretical introduction gives a good basis for subsequent parts of the book and is an independent and self-sufficient description of the most efficient theoretical methods of the strong-field and multiphoton physics. This book can serve as a textbook for graduate students

  10. Gyrokinetic electron acceleration in the force-free corona with anomalous resistivity

    OpenAIRE

    Arzner, Kaspar; Vlahos, Loukas

    2006-01-01

    We numerically explore electron acceleration and coronal heating by dissipative electric fields. Electrons are traced in linear force-free magnetic fields extrapolated from SOHO/MDI magnetograms, endowed with anomalous resistivity ($\\eta$) in localized dissipation regions where the magnetic twist $\

  11. Free electron lifetime achievements in Liquid Argon Imaging TPC

    CERN Document Server

    Baibussinov, B; Calligarich, E; Centro, S; Cieslik, K; Farnese, C; Fava, A; Gibin, D; Guglielmi, A; Meng, G; Pietropaolo, F; Rubbia, C; Varanini, F; Ventura, S

    2010-01-01

    A key feature for the success of the Liquid Argon TPC technology is the industrial purification against electro-negative impurities, especially Oxygen and Nitrogen remnants, which have to be initially and continuously kept at an exceptional purity. New purification techniques have been applied to a 120 litres LAr-TPC test facility in the INFN-LNL laboratory. Through-going muon tracks have been used to monitor the LAr purity. The short path length used (30 cm) is compensated by the high accuracy in the observation of the specific ionization of cosmic rays muons at sea level. A free electron lifetime of (21.4+7.3-4.3) ms, namely > 15.8 ms at 90 % C.L. has been observed under stable conditions over several weeks, corresponding to about 15 ppt (part per trillion) of Oxygen equivalent. At 500 V/cm, where the electron speed is approximately of 1.5 mm/us, the free electron lifetime >15 ms corresponds to an attenuation <15 % for a drift path of 5 m, opening the way to reliable operation of LAr TPC for exceptionall...

  12. The effect of scatter correction on {sup 123}I-IMP brain perfusion SPET with the triple energy window method in normal subjects using SPM analysis

    Energy Technology Data Exchange (ETDEWEB)

    Shiga, Tohru; Takano, Akihiro; Tsukamoto, Eriko; Tamaki, Nagara [Department of Nuclear Medicine, Hokkaido University School of Medicine, Sapporo (Japan); Kubo, Naoki [Department of Radiological Technology, College of Medical Technology, Hokkaido University, Sapporo (Japan); Kobayashi, Junko; Takeda, Yoji; Nakamura, Fumihiro; Koyama, Tsukasa [Department of Psychiatry and Neurology, Hokkaido University School of Medicine, Sapporo (Japan); Katoh, Chietsugu [Department of Tracer Kinetics, Hokkaido University School of Medicine, Sapporo (Japan)

    2002-03-01

    Scatter correction (SC) using the triple energy window method (TEW) has recently been applied for brain perfusion single-photon emission tomography (SPET). The aim of this study was to investigate the effect of scatter correction using TEW on N-isopropyl-p-[{sup 123}I]iodoamphetamine ({sup 123}I-IMP) SPET in normal subjects. The study population consisted of 15 right-handed normal subjects. SPET data were acquired from 20 min to 40 min after the injection of 167 MBq of IMP, using a triple-head gamma camera. Images were reconstructed with and without SC. 3D T1-weighted magnetic resonance (MR) images were also obtained with a 1.5-Tesla scanner. First, IMP images with and without SC were co-registered to the 3D MRI. Second, the two co-registered IMP images were normalised using SPM96. A t statistic image for the contrast condition effect was constructed. We investigated areas using a voxel-level threshold of 0.001, with a corrected threshold of 0.05. Compared with results obtained without SC, the IMP distribution with SC was significantly decreased in the peripheral areas of the cerebellum, the cortex and the ventricle, and also in the lateral occipital cortex and the base of the temporal lobe. On the other hand, the IMP distribution with SC was significantly increased in the anterior and posterior cingulate cortex, the insular cortex and the medial part of the thalamus. It is concluded that differences in the IMP distribution with and without SC exist not only in the peripheral areas of the cerebellum, the cortex and the ventricle but also in the occipital lobe, the base of the temporal lobe, the insular cortex, the medial part of the thalamus, and the anterior and posterior cingulate cortex. This needs to be recognised for adequate interpretation of IMP brain perfusion SPET after scatter correction. (orig.)

  13. Temperature dependence of electron mean free path in molybdenum from ultrasonic measurements

    Energy Technology Data Exchange (ETDEWEB)

    Almond, D P; Detwiler, D A; Rayne, J A [Carnegie-Mellon Univ., Pittsburgh, Pa. (USA)

    1975-09-08

    The temperature dependence of the electronic mean free path in molybdenum has been obtained from ultrasonic attenuation measurements.For temperature up to 30 K a T/sup -2/ law is followed suggesting the importance of electron-electron scattering in the attenuation mechanism.

  14. Short Rayleigh Length Free Electron Lasers

    CERN Document Server

    Crooker, P P; Armstead, R L; Blau, J

    2004-01-01

    Conventional free electron laser (FEL) oscillators minimize the optical mode volume around the electron beam in the undulator by making the resonator Rayleigh length about one third of the undulator length. This maximizes gain and beam-mode coupling. In compact configurations of high-power infrared FELs or moderate power UV FELs, the resulting optical intensity can damage the resonator mirrors. To increase the spot size and thereby reduce the optical intensity at the mirrors below the damage threshold, a shorter Rayleigh length can be used, but the FEL interaction is significantly altered. A new FEL interaction is described and analyzed with a Rayleigh length that is only one tenth the undulator length, or less. The effect of mirror vibration and positioning are more critical in the short Rayleigh length design, but we find that they are still within normal design tolerances.

  15. The group study of diagnostic efficacy of cerebro-vascular disease by I-123 IMP SPECT images obtained with ring type SPECT scanner

    International Nuclear Information System (INIS)

    Machida, Kikuo; Honda, Norinari; Matsumoto, Toru

    1991-01-01

    We performed two image reading experiments in order to investigate the diagnostic capability of I-123 IMP SPECT obtained by the ring type SPECT scanner in cerebro-vascular disease. Fourteen physicians diagnosed SPECT images of 55 cases with reference to clinical neurological information, first without brain XCT images and second with XCT images. Each physician detected perfusion defects and redistributions of I-123 IMP and assigned a confidence level of abnormality for these SPECT findings by means of five rating method. From results obtained by ROC analysis, we concluded as follows. (1) Generally, I-123 IMP SPECT is a stable diagnostic modality in the diagnosis of cerebro-vascular disease and the image reading of XCT had no effects on the diagnosis of SPECT on the whole of physician. (2) However, there were unnegligible differences among individuals in the detectability of findings and the effect of XCT image reading. (3) Detectability of redistribution of I-123 IMP was lower than that of perfusion defect and inter-observer variation in the diagnostic performance for redistribution was larger than that of perfusion defect. The results suggest that it is necessary to standardize diagnostic criteria among physicians for redistribution of I-123 IMP. (author)

  16. A control system for a free electron laser experiment

    International Nuclear Information System (INIS)

    Giove, D.

    1992-01-01

    The general layout of a control and data acquisition system for a Free Electron Laser experiment will be discussed. Some general considerations about the requirements and the architecture of the whole system will be developed. (author)

  17. Mean free path of electrons in rare gas solids

    International Nuclear Information System (INIS)

    Schwentner, N.

    1976-07-01

    The energy distribution of photoelectrons of solid Ar, Kr and Xe films with thickness between 10 A and 300 A have been measured in the photon energy range 10 eV to 30 eV using the synchrotron radiation of DESY. By varying the photon energy and the film thickness the dependence of the electron-electron scattering length on the electron kinetic energy has been determined. The mean free path for inelastic electron-electron scattering decreases monotonically from values of the order of 1.000 A at the scattering threshold to values between 1 A and 5 A for electron energies 10 eV above threshold. The observed energy dependence can be understood by a simplified bandstructure and a scattering probability described by a product of density of states. The threshold energy for electron-electron scattering lies between twice the energy of the n = 1 excitons and the sum of bandgap and exciton energy. (HK) [de

  18. Hexavalent Chrome Free Coatings for Electronics Applications: Joint Test Report

    Science.gov (United States)

    Rothgeb, Matt; Kessel, Kurt

    2013-01-01

    The overall objective of the Hexavalent Chrome Free Coatings for Electronics Applications project is to evaluate and test pretreatments not containing hexavalent chrome in avionics and electronics housing applications. This objective will be accomplished by testing strong performing coating systems from prior NASA and DoD testing or new coating systems as determined by the stakeholders.

  19. A review of electronic engineering design free software tools

    OpenAIRE

    Medrano Sánchez, Carlos; Plaza García, Inmaculada; Castro Gil, Manuel Alonso; García Sevilla, Francisco; Martínez Calero, J.D.; Pou Félix, Josep; Corbalán Fuertes, Montserrat

    2010-01-01

    In this paper, we review electronic design free software tools. We have searched open source programs that help with several tasks of the electronic design flow: analog and digital simulation, schematic capture, printed circuit board design and hardware description language compilation and simulation. Using some rapid criteria for verifying their availability, we have selected some of them which are worth working with. This work intends to perform a deeper analysis of fre...

  20. Regional cerebral blood flow in Parkinson's disease measured with N-isopropyl-p-[123I]iodoamphetamine (IMP) SPECT

    International Nuclear Information System (INIS)

    Odano, Ikuo; Nishihara, Mamiko; Hayashi, Hiroko; Higuchi, Shoichi; Sakai, Kunio; Ishikawa, Atsushi; Ibayashi, Katsuhiko.

    1992-01-01

    N-isopropyl-p-[ 123 I]iodoamphetamine (IMP) SPECT studies were performed on 21 patients (13 females; 45-73 yrs) with idiopathic Parkinson's disease (PD) and 10 age-matched normal controls (39-69 yrs). Regional cerebral blood flow (rCBF) was quantitatively measured by the arterial blood sampling method. When compared with normal controls, global CBF, and rCBF in the frontal cortex and in the basal ganglia were reduced 22.1% (p 123 I-IMP SPECT imaging is useful for evaluation and follow-up of patients with PD. (author)

  1. Gain of a Smith-Purcell free-electron laser

    Directory of Open Access Journals (Sweden)

    H. L. Andrews

    2004-07-01

    Full Text Available A formula is derived for the small-signal gain of a Smith-Purcell free-electron laser. The theory describes the electron beam as a moving plasma dielectric, and assumes that the electron beam interacts with an evanescent mode traveling along the surface of a periodic waveguide with a rectangular profile. The phase velocity of the evanescent wave is synchronous with the electron velocity, but the group velocity is actually negative. The electron beam amplifies the evanescent wave, which does not itself radiate. According to this picture, the radiation observed emanating from the grating is Smith-Purcell radiation enhanced by the bunching of the electrons due to the interaction with the evanescent mode. There will also be radiation from the part of the evanescent mode that is outcoupled from the ends of the grating. This radiation appears at a lower frequency than the Smith-Purcell radiation. The new results explain both the gain and the radiation observed in the experiments of Urata and Walsh, and the cube-root current dependence of the gain inferred by Bakhtyari, Walsh, and Brownell.

  2. Low-energy electron inelastic mean free path in materials

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen-Truong, Hieu T., E-mail: nguyentruongthanhhieu@tdt.edu.vn [Theoretical Physics Research Group & Faculty of Applied Sciences, Ton Duc Thang University, Ho Chi Minh City 756636 (Viet Nam)

    2016-04-25

    We show that the dielectric approach can determine electron inelastic mean free paths in materials with an accuracy equivalent to those from first-principle calculations in the GW approximation of many-body theory. The present approach is an alternative for calculating the hot-electron lifetime, which is an important quantity in ultrafast electron dynamics. This approach, applied here to solid copper for electron energies below 100 eV, yields results in agreement with experimental data from time-resolved two-photon photoemission, angle-resolved photoelectron spectroscopy, and X-ray absorption fine structure measurements in the energy ranges 2–3.5, 10–15, and 60–100 eV, respectively.

  3. Customer-experienced rapid prototyping

    Science.gov (United States)

    Zhang, Lijuan; Zhang, Fu; Li, Anbo

    2008-12-01

    In order to describe accurately and comprehend quickly the perfect GIS requirements, this article will integrate the ideas of QFD (Quality Function Deployment) and UML (Unified Modeling Language), and analyze the deficiency of prototype development model, and will propose the idea of the Customer-Experienced Rapid Prototyping (CE-RP) and describe in detail the process and framework of the CE-RP, from the angle of the characteristics of Modern-GIS. The CE-RP is mainly composed of Customer Tool-Sets (CTS), Developer Tool-Sets (DTS) and Barrier-Free Semantic Interpreter (BF-SI) and performed by two roles of customer and developer. The main purpose of the CE-RP is to produce the unified and authorized requirements data models between customer and software developer.

  4. PROCEEDING OF THE SEEDED X-RAY FREE ELECTRON LASER WORKSHOP.

    Energy Technology Data Exchange (ETDEWEB)

    WANG,X.J.; MURPHY,J.B.; YU,L.H.; FAATZ,B.; HUANG,Z.; REICHE,S.; ZOLOTOREV,M.

    2002-12-13

    The underlying theory of a high gain free electron laser (FEL) has existed for two decades [1-2], but it is only in the last few years that these novel radiation sources have been realized experimentally. Several high gain FELs have successfully reached saturation in the infrared, visible and the VUV portion of the spectrum: the High Gain Harmonic Generation (HGHG) free electron lasers [3] at BNL and the Self Amplified Spontaneous Emission (SASE) FELs at LEUTL, VISA and TTF [4-6]. The outstanding challenges for future FELs are to extend high gain FELs to the X-ray regime, improve the longitudinal coherence of the radiation using seeded FEL schemes and generate ultrashort pulses (<100 fs). The National Synchrotron Light Source (NSLS) of the Brookhaven National Laboratory (BNL) sponsored a Seeded X-ray Free Electron Laser Workshop on December 13-14, 2002 to explore these challenging issues. Representatives from BNL, DESY, LBNL, SLAC and UCLA made presentations on the novel schemes under consideration at their laboratories. Workshop participants had a lively discussion on the feasibility, performance and R&D issues associated with the seeded XFEL schemes. An improvement of the electron beam quality will certainly be necessary to drive the XFEL. Self-seeding SASE, cascaded HGHG, and SASE pulse compression FELs show the most promise for producing short pulse X-rays. Of these, only the self-seeded and HGHG schemes generate longitudinally coherent radiation. While the pulse length in the self-seeded scheme is determined by the electron bunch length ({approx}100 fs), the pulse length in the HGHG scheme is determined by the short pulse seed laser, and so can be much shorter ({approx} 20 fs).

  5. From Storage Rings to Free Electron Lasers for Hard X-Rays

    International Nuclear Information System (INIS)

    Nuhn, H

    2004-01-01

    The intensity of X-ray sources has increased at a rapid rate since the late 1960s by 10 orders of magnitude and more through the use of synchrotron radiation produced by bending magnets, wigglers and undulators. Three generations of radiation sources have been identified depending on amplitude and quality of the radiation provided. While user facilities of the third generation were being constructed a new concept of radiation generating devices was being developed that offers an even larger increase in peak and average brightness than had been achieved till then. The new concept of the X-ray Free Electron Laser based on the principle of Self-Amplified Spontaneous Emission will be the basis of fourth generation X-ray source user facilities of this century. The paper will start with a brief history of the development of x-ray sources, discuss some of the differences between storage ring and free electron laser based approaches, and close with an update of the present development of x-ray free electron laser user facilities

  6. From Storage Rings to Free Electron Lasers for Hard X-Rays

    Energy Technology Data Exchange (ETDEWEB)

    Nuhn, H

    2004-01-09

    The intensity of X-ray sources has increased at a rapid rate since the late 1960s by 10 orders of magnitude and more through the use of synchrotron radiation produced by bending magnets, wigglers and undulators. Three generations of radiation sources have been identified depending on amplitude and quality of the radiation provided. While user facilities of the third generation were being constructed a new concept of radiation generating devices was being developed that offers an even larger increase in peak and average brightness than had been achieved till then. The new concept of the X-ray Free Electron Laser based on the principle of Self-Amplified Spontaneous Emission will be the basis of fourth generation X-ray source user facilities of this century. The paper will start with a brief history of the development of x-ray sources, discuss some of the differences between storage ring and free electron laser based approaches, and close with an update of the present development of x-ray free electron laser user facilities.

  7. From storage rings to free electron lasers for hard x-rays

    International Nuclear Information System (INIS)

    Nuhn, Heinz-Dieter

    2004-01-01

    The intensity of x-ray sources has increased at a rapid rate since the late 1960s by ten orders of magnitude and more through the use of synchrotron radiation produced by bending magnets, wigglers and undulators. Three generations of radiation sources have been identified depending on amplitude and quality of the radiation provided. While user facilities of the third generation were being constructed, a new concept of radiation generating devices was being developed that offers an even larger increase in peak and average brightness than had been achieved till then. The new concept of the x-ray free electron laser based on the principle of self-amplified spontaneous emission will be the basis of fourth generation x-ray source user facilities of this century. The paper will start with a brief history of the development of x-ray sources, it will then discuss some of the differences between storage ring and free electron laser based approaches, and will close with an update of the present development of x-ray free electron laser user facilities

  8. 6. Seminar of the IIE-ININ-IMP on technological specialties. Topic 4: dynamics

    International Nuclear Information System (INIS)

    1992-01-01

    The document includes 7 papers presented at the 6. Seminar of the IIE-ININ-IMP (Mexico) on technological specialties in the field of dynamics. (Topic 4). One item was in INIS subject scope and a separate abstract was prepared for it

  9. Comment on 'magnetosheath burst of predominantly medium nuclei observed with Imp 8 on February 16, 1974' by T. P. Armstrong, S. M. Krimigis, and R. P. Lepping

    Science.gov (United States)

    Hovestadt, D.

    1980-01-01

    Armstrong et al. (1978) have observed a unique series of bursts with an unusually high content of Z greater than 2 particles and a high degree of collimation from the direction of the sun. The bursts were observed only with the CPME (Charged Particle Measurement Instrument) on Imp 8, but not with the CPME on Imp 7 nor with the ULET (Ultralow Energy Telescope) on Imp 8, whose response characteristics matched those of the CPME on Imp 7. The present comparison of the measurements made with the CPME and ULET cast doubt on the correctness of the reported observations.

  10. Commissioning of the readout electronics for the prototypes of a hadronic calorimeter and a tailcatcher and muon tracker

    International Nuclear Information System (INIS)

    Lutz, B.

    2006-12-01

    The goal of the CALICE collaboration is to develop and design a highly granular calorimeter for an experiment at the future international linear collider. In an integrated study all parts of the calorimeter are considered. Within this project a hadronic calorimeter prototype, built at DESY, and a tailcatcher and muon tracker prototype, built at NIU and Fermilab, are developed. The subject of this thesis is the combined readout electronics for these prototypes. In a set of measurements it is demonstrated that the individual components answer their purposes. This includes the classification of noise, linearity and signal to noise ratio of the amplifier and a study of the differential nonlinearity of the analog to digital converter in the data acquisition. In addition to these measurements of common parameters, some attributes are measured that are special to the use of the combined system, including the influence of the limited time resolution of the hold signal and the consequences of signals with variable input signal shape. Furthermore, an algorithm is developed for the determination of the SiPM gain from single photoelectron spectra that are recorded with the detector readout electronics. Particular effort is made to ensure that the developed method can be run independently from human intervention, as a 8000 channel system demands. The accuracy and stability of the gain measurement is checked with actual data from the first available hadronic calorimeter modules and a set of requirements for a measurement of 1% accuracy is fixed. Finally, the established gain measurement is used in the calibration of modules with cosmic muons. And the temperature dependence of the SiPM gain is verified. (orig.)

  11. Commissioning of the readout electronics for the prototypes of a hadronic calorimeter and a tailcatcher and muon tracker

    Energy Technology Data Exchange (ETDEWEB)

    Lutz, B.

    2006-12-15

    The goal of the CALICE collaboration is to develop and design a highly granular calorimeter for an experiment at the future international linear collider. In an integrated study all parts of the calorimeter are considered. Within this project a hadronic calorimeter prototype, built at DESY, and a tailcatcher and muon tracker prototype, built at NIU and Fermilab, are developed. The subject of this thesis is the combined readout electronics for these prototypes. In a set of measurements it is demonstrated that the individual components answer their purposes. This includes the classification of noise, linearity and signal to noise ratio of the amplifier and a study of the differential nonlinearity of the analog to digital converter in the data acquisition. In addition to these measurements of common parameters, some attributes are measured that are special to the use of the combined system, including the influence of the limited time resolution of the hold signal and the consequences of signals with variable input signal shape. Furthermore, an algorithm is developed for the determination of the SiPM gain from single photoelectron spectra that are recorded with the detector readout electronics. Particular effort is made to ensure that the developed method can be run independently from human intervention, as a 8000 channel system demands. The accuracy and stability of the gain measurement is checked with actual data from the first available hadronic calorimeter modules and a set of requirements for a measurement of 1% accuracy is fixed. Finally, the established gain measurement is used in the calibration of modules with cosmic muons. And the temperature dependence of the SiPM gain is verified. (orig.)

  12. Development and Testing of a Prototype Grid-Tied Photovoltaic Power System

    Science.gov (United States)

    Eichenberg, Dennis J.

    2009-01-01

    The NASA Glenn Research Center (GRC) has developed and tested a prototype 2 kW DC grid-tied photovoltaic (PV) power system at the Center. The PV system has generated in excess of 6700 kWh since operation commenced in July 2006. The PV system is providing power to the GRC grid for use by all. Operation of the prototype PV system has been completely trouble free. A grid-tied PV power system is connected directly to the utility distribution grid. Facility power can be obtained from the utility system as normal. The PV system is synchronized with the utility system to provide power for the facility, and excess power is provided to the utility. The project transfers space technology to terrestrial use via nontraditional partners. GRC personnel glean valuable experience with PV power systems that are directly applicable to various space power systems, and provide valuable space program test data. PV power systems help to reduce harmful emissions and reduce the Nation s dependence on fossil fuels. Power generated by the PV system reduces the GRC utility demand, and the surplus power aids the community. Present global energy concerns reinforce the need for the development of alternative energy systems. Modern PV panels are readily available, reliable, efficient, and economical with a life expectancy of at least 25 years. Modern electronics has been the enabling technology behind grid-tied power systems, making them safe, reliable, efficient, and economical with a life expectancy of at least 25 years. Based upon the success of the prototype PV system, additional PV power system expansion at GRC is under consideration. The prototype grid-tied PV power system was successfully designed and developed which served to validate the basic principles described, and the theoretical work that was performed. The report concludes that grid-tied photovoltaic power systems are reliable, maintenance free, long life power systems, and are of significant value to NASA and the community.

  13. Linear Gain and Gain Saturation in a Photonic Free-Electron Laser

    NARCIS (Netherlands)

    Denis, T.; Boller, Klaus J.; Lee, J.H.H.; van der Slot, P.J.M.; van Dijk, Marc

    2012-01-01

    Photonic crystals are used to manipulate the generation of light, for example, stimulated emission can be enhanced. A photonic free-electron laser (pFEL) applies this enhancement to generate widely tunable coherent Cerenkov radiation from low energy electrons (keV) streaming through the photonic

  14. Electron Bunch Timing with Femtosecond Precision in a Superconducting Free-Electron Laser

    Science.gov (United States)

    Löhl, F.; Arsov, V.; Felber, M.; Hacker, K.; Jalmuzna, W.; Lorbeer, B.; Ludwig, F.; Matthiesen, K.-H.; Schlarb, H.; Schmidt, B.; Schmüser, P.; Schulz, S.; Szewinski, J.; Winter, A.; Zemella, J.

    2010-04-01

    High-gain free-electron lasers (FELs) are capable of generating femtosecond x-ray pulses with peak brilliances many orders of magnitude higher than at other existing x-ray sources. In order to fully exploit the opportunities offered by these femtosecond light pulses in time-resolved experiments, an unprecedented synchronization accuracy is required. In this Letter, we distributed the pulse train of a mode-locked fiber laser with femtosecond stability to different locations in the linear accelerator of the soft x-ray FEL FLASH. A novel electro-optic detection scheme was applied to measure the electron bunch arrival time with an as yet unrivaled precision of 6 fs (rms). With two beam-based feedback systems we succeeded in stabilizing both the arrival time and the electron bunch compression process within two magnetic chicanes, yielding a significant reduction of the FEL pulse energy jitter.

  15. Two electron response to an intense x-ray free electron laser pulse

    International Nuclear Information System (INIS)

    Moore, L R; Parker, J S; Meharg, K J; Armstrong, G S J; Taylor, K T

    2009-01-01

    New x-ray free electron lasers (FELs) promise an ultra-fast ultra-intense regime in which new physical phenomena, such as double core hole formation in at atom, should become directly observable. Ahead of x-ray FEL experiments, an initial key task is to theoretically explore such fundamental laser-atom interactions and processes. To study the response of a two-electron positive ion to an intense x-ray FEL pulse, our theoretical approach is a direct numerical integration, incorporating non-dipole Hamiltonian terms, of the full six-dimensional time-dependent Schroedinger equation. We present probabilities of double K-shell ionization in the two-electron positive ions Ne 8+ and Ar 16+ exposed to x-ray FEL pulses with frequencies in the range 50 au to 300 au and intensities in the range 10 17 to 10 22 W/cm 2 .

  16. Electron Bunch Timing with Femtosecond Precision in a Superconducting Free-Electron Laser

    International Nuclear Information System (INIS)

    Loehl, F.; Arsov, V.; Felber, M.; Hacker, K.; Lorbeer, B.; Ludwig, F.; Matthiesen, K.-H.; Schlarb, H.; Schmidt, B.; Winter, A.; Jalmuzna, W.; Schmueser, P.; Schulz, S.; Zemella, J.; Szewinski, J.

    2010-01-01

    High-gain free-electron lasers (FELs) are capable of generating femtosecond x-ray pulses with peak brilliances many orders of magnitude higher than at other existing x-ray sources. In order to fully exploit the opportunities offered by these femtosecond light pulses in time-resolved experiments, an unprecedented synchronization accuracy is required. In this Letter, we distributed the pulse train of a mode-locked fiber laser with femtosecond stability to different locations in the linear accelerator of the soft x-ray FEL FLASH. A novel electro-optic detection scheme was applied to measure the electron bunch arrival time with an as yet unrivaled precision of 6 fs (rms). With two beam-based feedback systems we succeeded in stabilizing both the arrival time and the electron bunch compression process within two magnetic chicanes, yielding a significant reduction of the FEL pulse energy jitter.

  17. A new treatment of capillarity to improve the stability of IMPES two-phase flow formulation

    KAUST Repository

    Kou, Jisheng

    2010-12-01

    In this paper, we present an efficient numerical method for two-phase immiscible flow in porous media with different capillarity pressures. In highly heterogeneous permeable media, the saturation is discontinuous due to different capillary pressure functions. One popular scheme is to split the system into a pressure and a saturation equation, and to apply IMplicit Pressure Explicit Saturation (IMPES) approach for time stepping. One disadvantage of IMPES is instability resulting from the explicit treatment for capillary pressure. To improve stability, the capillary pressure is usually incorporated in the saturation equation which gradients of saturation appear. This approach, however, does not apply to the case of different capillary pressure functions for multiple rock-types, because of the discontinuity of saturation across rock interfaces. In this paper, we present a new treatment of capillary pressure, which appears implicitly in the pressure equation. Using an approximation of capillary function, we substitute the implicit saturation equation into the pressure equation. The coupled pressure equation will be solved implicitly and followed by the explicit saturation equation. Five numerical examples are provided to demonstrate the advantages of our approach. Comparison shows that our proposed method is more efficient and stable than the classical IMPES approach. © 2010 Elsevier Ltd.

  18. Clinical experience of 123I-IMP scintigraphy in detecting vertebral bone metastases of hepatocellular carcinoma. A comparison with bone scintigraphy with 99mTc-MDP

    International Nuclear Information System (INIS)

    Suto, Y.; Iwamiya, T.; Tanigawa, N.; Shabana, M.; Ohta, Y.

    1994-01-01

    123 I-IMP and bone scintigraphy with 99m Tc-MDP were consecutively performed in patients with vertebral bone metastases from hepatocellular carcinoma and lumbar spondylosis deformans in a 7-day interval or shorter. The intensity of uptake was compared. Eighteen of the 20 metastatic lesions (90%) were classified as increased uptake areas in 123 I-IMP scintigraphy. MDP-scintigraphy disclosed 16 metastatic lesions (80%), 9 as ''hot'' lesions (56%) and 7 as ''cold'' lesions (44%). 123 I-IMP scintigraphy was negative in all 12 lesions of lumbar spondylosis deformans. Compared to MDP-scintigraphy, 123 I-IMP scintigraphy was more sensitive in detecting vertebral bone metastases of hepatocellular carcinoma with smaller rates of false-positive and false-negative findings. (orig./MG)

  19. Free electron laser variable bridge coupler

    International Nuclear Information System (INIS)

    Spalek, G.; Billen, J.H.; Garcia, J.A.; McMurry, D.E.; Harnsborough, L.D.; Giles, P.M.; Stevens, S.B.

    1985-01-01

    The Los Alamos free-electron laser (FEL) is being modified to test a scheme for recovering most of the power in the residual 20-MeV electron beam by decelerating the microbunches in a linear standing-wave accelerator and using the recovered energy to accelerate new beam. A variable-coupler low-power model that resonantly couples the accelerator and decelerator structures has been built and tested. By mixing the TE 101 and TE 102 modes, this device permits continuous variation of the decelerator fields relative to the accelerator fields through a range of 1:1 to 1:2.5. Phase differences between the two structures are kept below 1 0 and are independent of power-flow direction. The rf power is also fed to the two structures through this coupling device. Measurements were also made on a three-post-loaded variable coupler that is a promising candidate for the same task

  20. Reduction in cortical IMP-SPET tracer uptake with recent cigarette consumption in a young group of healthy males

    International Nuclear Information System (INIS)

    Rourke, S.B.; Dupont, R.M.; Grant, I.; Lehr, P.P.; Lamoureux, G.; Halpern, S.; Yeung, D.W.C.

    1997-01-01

    Functional brain imaging techniques are being used increasingly to infer disturbances in brain function in various neuropsychiatric disorders, but the specificity of such findings is not always clear. We retrospectively examined the effects of one possible confound - cigarette smoking - on cortical uptake of iodine-123 iodoamphetamine (IMP) using single-photon emission tomographic imaging in a young (mean age=35 years) healthy group of male controls divided according to their smoking history. Subjects who had never smoked (n=17), or those with a history of smoking but no recent smoking (n=8), had equivalent and significantly higher mean cortical uptake of IMP than subjects with a history of smoking and who were current smokers (n=8). There were no differences in the cortical distribution of IMP. Our results indicate that cigarette smoking has an acute effect on global cerebral blood flow. This potential confound must be considered before abnormalities in cortical tracer uptake are attributed to some neuropsychiatric disorder of interest. (orig.). With 2 figs., 3 tabs

  1. I-123 IMP SPECT in Parkinson's disease; In relation to the presence or absence of dementia

    Energy Technology Data Exchange (ETDEWEB)

    Kawabata, Keita; Tachibana, Kyudai; Sugita, Minoru [Hyogo Medical Coll., Nishinomiya (Japan)

    1990-12-01

    To examine semiquantitatively regional cerebral blood flow, SPECT with N-isopropyl-p-(I-123)iodoamphetamine (I-123 IMP) was undertaken in 17 patients with Parkinson's disease. Seven patients with Alzheimer's disease and 9 senile control subjects were also imaged for comparison. Both the Parkinson's disease group and the Alzheimer's disease group had a decreased uptake of I-123 IMP in the frontal lobe, in comparison with the control group. A remarkably decreased uptake was seen in the lateral and parietal lobes in the group of Parkinson's disease associated with dementia, as well as in the Alzheimer's disease group. A significantly decreased uptake was observed in the frontal lobe, lateral lobe, thalamus, and basal ganglia in the Parkinson's disease group, irrespective of the presence or absence of dementia. For Parkinson's disease associated with dementia, there was much more significant decrease in I-123 IMP uptake. The pattern of regional cerebral blood flow in the Alzheimer's disease group was analogous to that in the Parkinson's disease group associated with dementia. This supports the hypothesis that Alzheimer's disease may be somewhat involved in the occurrence of dementia for Parkinson's disease. (N.K.).

  2. Prompt and Precise Prototyping

    Science.gov (United States)

    2003-01-01

    For Sanders Design International, Inc., of Wilton, New Hampshire, every passing second between the concept and realization of a product is essential to succeed in the rapid prototyping industry where amongst heavy competition, faster time-to-market means more business. To separate itself from its rivals, Sanders Design aligned with NASA's Marshall Space Flight Center to develop what it considers to be the most accurate rapid prototyping machine for fabrication of extremely precise tooling prototypes. The company's Rapid ToolMaker System has revolutionized production of high quality, small-to-medium sized prototype patterns and tooling molds with an exactness that surpasses that of computer numerically-controlled (CNC) machining devices. Created with funding and support from Marshall under a Small Business Innovation Research (SBIR) contract, the Rapid ToolMaker is a dual-use technology with applications in both commercial and military aerospace fields. The advanced technology provides cost savings in the design and manufacturing of automotive, electronic, and medical parts, as well as in other areas of consumer interest, such as jewelry and toys. For aerospace applications, the Rapid ToolMaker enables fabrication of high-quality turbine and compressor blades for jet engines on unmanned air vehicles, aircraft, and missiles.

  3. 6. Seminar of the IIE-ININ-IMP on technological specialties. Topic 8: computation

    International Nuclear Information System (INIS)

    1992-01-01

    The document includes 10 papers presented at the 6. Seminar of the IIE-ININ-IMP (Mexico) on technological specialties in the field of computation. (Topic 8). Three items were in INIS subject scope and a separate abstract was prepared for each of them

  4. Inflammation-free, gas-permeable, lightweight, stretchable on-skin electronics with nanomeshes

    Science.gov (United States)

    Miyamoto, Akihito; Lee, Sungwon; Cooray, Nawalage Florence; Lee, Sunghoon; Mori, Mami; Matsuhisa, Naoji; Jin, Hanbit; Yoda, Leona; Yokota, Tomoyuki; Itoh, Akira; Sekino, Masaki; Kawasaki, Hiroshi; Ebihara, Tamotsu; Amagai, Masayuki; Someya, Takao

    2017-09-01

    Thin-film electronic devices can be integrated with skin for health monitoring and/or for interfacing with machines. Minimal invasiveness is highly desirable when applying wearable electronics directly onto human skin. However, manufacturing such on-skin electronics on planar substrates results in limited gas permeability. Therefore, it is necessary to systematically investigate their long-term physiological and psychological effects. As a demonstration of substrate-free electronics, here we show the successful fabrication of inflammation-free, highly gas-permeable, ultrathin, lightweight and stretchable sensors that can be directly laminated onto human skin for long periods of time, realized with a conductive nanomesh structure. A one-week skin patch test revealed that the risk of inflammation caused by on-skin sensors can be significantly suppressed by using the nanomesh sensors. Furthermore, a wireless system that can detect touch, temperature and pressure is successfully demonstrated using a nanomesh with excellent mechanical durability. In addition, electromyogram recordings were successfully taken with minimal discomfort to the user.

  5. The first interdisciplinary experiments at the IMP high energy microbeam

    Energy Technology Data Exchange (ETDEWEB)

    Du, Guanghua; Guo, Jinlong; Wu, Ruqun; Guo, Na; Liu, Wenjing; Ye, Fei; Sheng, Lina; Li, Qiang [Institute of Modern Physics (IMP), Chinese Academy of Sciences, Lanzhou (China); Li, Huiyun [Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen (China)

    2015-04-01

    The high energy beam of tens to hundred MeV/u ions possesses mm-to-cm penetration depth in materials and can be easily extracted into air without significant energy loss and beam scattering. Combination of high energy ions and microbeam technology facilitates the microprobe application to many practical studies in large scale samples. The IMP heavy ion microbeam facility has recently been integrated with microscopic positioning and targeting irradiation system. This paper introduced the first interdisciplinary experiments performed at the IMP microbeam facility using the beam of 80.5 MeV/u carbon ions. Bystander effect induction via medium transferring was not found in the micro-irradiation study using HeLa cells. The mouse irradiation experiment demonstrated that carbon irradiation of 10 Gy dose to its tuberomammillary nucleus did not impair the sleep nerve system. The fault injection attack on RSA (Rivest–Shamir–Adleman) decryption proved that the commercial field-programmable gate array chip is vulnerable in single event effect to low linear-energy-transfer carbon irradiation, and the attack can cause the leakage of RSA private key. This work demonstrates the potential of high energy microbeam in its application to biology, biomedical, radiation hardness, and information security studies.

  6. [123I]-IMP SPECT findings in spinocerebellar ataxia type 6

    International Nuclear Information System (INIS)

    Ito, Yasuhiko; Nakabayashi, Haruo; Iguchi, Yasuyuki; Suzuki, Masahiko; Kobayashi, Masayuki; Nakajima, Takashi

    2000-01-01

    To study the dynamics of metabolic function in the cerebellar hemispheres, vermis and brain stem of patients with spinocerebellar ataxia type 6 (SCA6), we used single photon emission computed tomography (SPECT) with N-isopropyl-p-[ 123 I] iodoamphetamine (IMP) to measure regional cerebral blood flow (rCBF) in six Japanese patients with SCA6 and nine normal control subjects. All patients with SCA6 were found to have expanded CAG repeats (from 22 to 24 repeats). The SPECT data were also analyzed semiquantitatively. The rCBF in the cerebellar hemisphere, vermis and brain stem was not significantly lower in patients with SCA6 than in normal controls. However, the ratio of the cerebellar hemisphere to occipital lobe (C/O ratio) was significantly lower in patients. The ratio of the vermis and brain stem to occipital lobe (V/O, P/O ratio) were not significantly lower in patients. The C/O, V/O and P/O ratio were especially sensitive indexes for regional cerebral function in patients with SCA6. Results of this study suggest that the functional decrease in SCA6 may begin in the cerebellar hemispheres. IMP SPECT was useful for evaluating rCBF in patients with SCA6. (author)

  7. The quantum mechanical analysis of the free electron laser

    International Nuclear Information System (INIS)

    Dattoli, G.; Renieri, A.

    1985-01-01

    A quantum analysis of the Free Electron Laser is presented. The theory is developed both in single and longitudinal multimode regimes. Finally a self-consistent procedure to study the growth of the laser signal from the vacuum to the macroscopic level is presented

  8. Detailed characterization of electron sources yielding first demonstration of European X-ray Free-Electron Laser beam quality

    Directory of Open Access Journals (Sweden)

    F. Stephan

    2010-02-01

    Full Text Available The photoinjector test facility at DESY, Zeuthen site (PITZ, was built to develop and optimize photoelectron sources for superconducting linacs for high-brilliance, short-wavelength free-electron laser (FEL applications like the free-electron laser in Hamburg (FLASH and the European x-ray free-electron laser (XFEL. In this paper, the detailed characterization of two laser-driven rf guns with different operating conditions is described. One experimental optimization of the beam parameters was performed at an accelerating gradient of about 43  MV/m at the photocathode and the other at about 60  MV/m. In both cases, electron beams with very high phase-space density have been demonstrated at a bunch charge of 1 nC and are compared with corresponding simulations. The rf gun optimized for the lower gradient has surpassed all the FLASH requirements on beam quality and rf parameters (gradient, rf pulse length, repetition rate and serves as a spare gun for this facility. The rf gun studied with increased accelerating gradient at the cathode produced beams with even higher brightness, yielding the first demonstration of the beam quality required for driving the European XFEL: The geometric mean of the normalized projected rms emittance in the two transverse directions was measured to be 1.26±0.13  mm mrad for a 1-nC electron bunch. When a 10% charge cut is applied excluding electrons from those phase-space regions where the measured phase-space density is below a certain level and which are not expected to contribute to the lasing process, the normalized projected rms emittance is about 0.9 mm mrad.

  9. Modified two beam accelerator driven by a D.C. pelletron free electron laser

    International Nuclear Information System (INIS)

    Larson, D.

    1985-01-01

    Assembling the next generation of linear particle accelerators requires progress in three areas. (1) Sources must be developed to provide the coherent electromagnetic radiation used to power the device. (2) Physical structures must be designed which efficiently transfer the power to the high energy beam. (3) Cooling techniques must be developed in order to enhance beam transport and to provide sufficient luminosity. This paper will describe a method of obtaining a highly efficient coherent radiation source by using a continuous wave Free Electron Laser (FEL). Several possibilities exist for an accelerating structure which could use this radiation as a power source. These include scaling down the size of traditional RF cavities, inverse free electron lasers, and surface grating schemes. Inverse free electron lasers have the possibility of intrinsic cooling of the high energy beam

  10. Dedicated very front-end electronics for an ILC prototype hadronic calorimeter with SiPM read-out

    CERN Document Server

    de La Taille, C

    2008-01-01

    The SPIROC chip is a dedicated very front-end electronics for an ILC prototype hadronic calorimeter with Silicon photomultiplier (or MPPC) readout. This ASIC is due to equip a 10,000-channel demonstrator in 2009. SPIROC is an evolution of FLC_SiPM used for the ILC AHCAL physics prototype [1]. SPIROC was submitted in June 2007 and will be tested in September 2007. It embeds cutting edge features that fulfil ILC final detector requirements. It has been realized in 0.35m SiGe technology. It has been developed to match the requirements of large dynamic range, low noise, low consumption, high precision and large number of readout channels needed. SPIROC is an auto-triggered, bi-gain, 36-channel ASIC which allows to measure on each channel the charge from one photoelectron to 2000 and the time with a 100ps accurate TDC. An analogue memory array with a depth of 16 for each channel is used to store the time information and the charge measurement. A 12-bit Wilkinson ADC has been embedded to digitize the analogue memor...

  11. Readout electronics for the SiPM tracking plane in the NEXT-1 prototype

    International Nuclear Information System (INIS)

    Herrero, V.; Toledo, J.; Català, J.M.; Esteve, R.; Gil, A.; Lorca, D.; Monzó, J.M.; Sanchis, F.; Verdugo, A.

    2012-01-01

    NEXT is a new experiment to search for neutrinoless double beta decay using a 100 kg radio-pure high-pressure gaseous xenon TPC with electroluminescence readout. A large-scale prototype with a SiPM tracking plane has been built. The primary electron paths can be reconstructed from time-resolved measurements of the light that arrives to the SiPM plane. Our approach is to measure how many photons have reached each SiPM sensor each microsecond with a gated integrator. We have designed and tested a 16-channel front-end board that includes the analog paths and a digital section. Each analog path consists of three different stages: a transimpedance amplifier, a gated integrator and an offset and gain control stage. Measurements show good linearity and the ability to detect single photoelectrons.

  12. Readout electronics for the SiPM tracking plane in the NEXT-1 prototype

    Energy Technology Data Exchange (ETDEWEB)

    Herrero, V. [Instituto de Instrumentacion para Imagen Molecular I3M (Centro mixto CSIC-Universitat Politecnica de Valencia-CIEMAT), 46022 Valencia (Spain); Toledo, J., E-mail: jtoledo@eln.upv.es [Instituto de Instrumentacion para Imagen Molecular I3M (Centro mixto CSIC-Universitat Politecnica de Valencia-CIEMAT), 46022 Valencia (Spain); Catala, J.M.; Esteve, R. [Instituto de Instrumentacion para Imagen Molecular I3M (Centro mixto CSIC-Universitat Politecnica de Valencia-CIEMAT), 46022 Valencia (Spain); Gil, A.; Lorca, D. [Instituto de Fisica Corpuscular (CSIC-Universidad de Valencia), 46980 Valencia (Spain); Monzo, J.M.; Sanchis, F. [Instituto de Instrumentacion para Imagen Molecular I3M (Centro mixto CSIC-Universitat Politecnica de Valencia-CIEMAT), 46022 Valencia (Spain); Verdugo, A. [CIEMAT-Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas, Madrid (Spain)

    2012-12-11

    NEXT is a new experiment to search for neutrinoless double beta decay using a 100 kg radio-pure high-pressure gaseous xenon TPC with electroluminescence readout. A large-scale prototype with a SiPM tracking plane has been built. The primary electron paths can be reconstructed from time-resolved measurements of the light that arrives to the SiPM plane. Our approach is to measure how many photons have reached each SiPM sensor each microsecond with a gated integrator. We have designed and tested a 16-channel front-end board that includes the analog paths and a digital section. Each analog path consists of three different stages: a transimpedance amplifier, a gated integrator and an offset and gain control stage. Measurements show good linearity and the ability to detect single photoelectrons.

  13. Beam Tests of a Multilayer LumiCal Prototype

    CERN Document Server

    Borysov, O

    2018-01-01

    LumiCal is a sampling electromagnetic calorimeter designed for the precise measurement of in- tegrated luminosity in electron positron linear collider experiments. The present report contains a description and results of the first beam test of a multilayer LumiCal prototype with four sili- con detector planes. A 5 GeV electron beam from the CERN PS T9 facility was used to study the performance of the LumiCal prototype. Presented results are mainly focused on the trans- verse structure of the observed electromagnetic shower and the Molière radius measurement. A comparison with MC simulation is also discussed.

  14. Two electron response to an intense x-ray free electron laser pulse

    Energy Technology Data Exchange (ETDEWEB)

    Moore, L R; Parker, J S; Meharg, K J; Armstrong, G S J; Taylor, K T, E-mail: l.moore@qub.ac.u [DAMTP, David Bates Building, Queen' s University Belfast, Belfast, BT7 1NN (United Kingdom)

    2009-11-01

    New x-ray free electron lasers (FELs) promise an ultra-fast ultra-intense regime in which new physical phenomena, such as double core hole formation in at atom, should become directly observable. Ahead of x-ray FEL experiments, an initial key task is to theoretically explore such fundamental laser-atom interactions and processes. To study the response of a two-electron positive ion to an intense x-ray FEL pulse, our theoretical approach is a direct numerical integration, incorporating non-dipole Hamiltonian terms, of the full six-dimensional time-dependent Schroedinger equation. We present probabilities of double K-shell ionization in the two-electron positive ions Ne{sup 8+} and Ar{sup 16+} exposed to x-ray FEL pulses with frequencies in the range 50 au to 300 au and intensities in the range 10{sup 17} to 10{sup 22} W/cm{sup 2}.

  15. 8. Seminar of the IMP-IIE-ININ on technological specialties. Topic 10: Earth Sciences

    International Nuclear Information System (INIS)

    1996-01-01

    The document contains two papers within INIS subject scope which were presented at the 8th Seminar of the IMP-IIE-ININ on technological specialties. Topic 10: Earth Sciences. A separate abstract was prepared for each paper

  16. High Power Electron Accelerator Prototype

    CERN Document Server

    Tkachenko, Vadim; Cheskidov, Vladimir; Korobeynikov, G I; Kuznetsov, Gennady I; Lukin, A N; Makarov, Ivan; Ostreiko, Gennady; Panfilov, Alexander; Sidorov, Alexey; Tarnetsky, Vladimir V; Tiunov, Michael A

    2005-01-01

    In recent time the new powerful industrial electron accelerators appear on market. It caused the increased interest to radiation technologies using high energy X-rays due to their high penetration ability. However, because of low efficiency of X-ray conversion for electrons with energy below 5 MeV, the intensity of X-rays required for some industrial applications can be achieved only when the beam power exceeds 300 kW. The report describes a project of industrial electron accelerator ILU-12 for electron energy up to 5 MeV and beam power up to 300 kW specially designed for use in industrial applications. On the first stage of work we plan to use the existing generator designed for ILU-8 accelerator. It is realized on the GI-50A triode and provides the pulse power up to 1.5-2 MW and up to 20-30 kW of average power. In the report the basic concepts and a condition of the project for today are reflected.

  17. Free radicals imaged in vivo in the rat by using proton-electron double-resonance imaging

    International Nuclear Information System (INIS)

    Lurie, D.J.; Nicholson, Ian; Foster, M.A.; Mallard, J.R.

    1990-01-01

    A new technique called proton-electron double-resonance imaging is described for imaging free radicals in aqueous samples. The method is a combination of proton NMR imaging with nuclear electron double resonance. The results of using this technique to image free radicals in vivo in the rat are presented. Rats were injected intravenously with a nitroxide free radical solution and a series of images was obtained from which the clearance of the free radical through the liver and kidneys could be observed. (author)

  18. Characterization of a Reconfigurable Free-Space Optical Channel for Embedded Computer Applications with Experimental Validation Using Rapid Prototyping Technology

    Directory of Open Access Journals (Sweden)

    Rafael Gil-Otero

    2007-02-01

    Full Text Available Free-space optical interconnects (FSOIs are widely seen as a potential solution to current and future bandwidth bottlenecks for parallel processors. In this paper, an FSOI system called optical highway (OH is proposed. The OH uses polarizing beam splitter-liquid crystal plate (PBS/LC assemblies to perform reconfigurable beam combination functions. The properties of the OH make it suitable for embedding complex network topologies such as completed connected mesh or hypercube. This paper proposes the use of rapid prototyping technology for implementing an optomechanical system suitable for studying the reconfigurable characteristics of a free-space optical channel. Additionally, it reports how the limited contrast ratio of the optical components can affect the attenuation of the optical signal and the crosstalk caused by misdirected signals. Different techniques are also proposed in order to increase the optical modulation amplitude (OMA of the system.

  19. Characterization of a Reconfigurable Free-Space Optical Channel for Embedded Computer Applications with Experimental Validation Using Rapid Prototyping Technology

    Directory of Open Access Journals (Sweden)

    Lim Theodore

    2007-01-01

    Full Text Available Free-space optical interconnects (FSOIs are widely seen as a potential solution to current and future bandwidth bottlenecks for parallel processors. In this paper, an FSOI system called optical highway (OH is proposed. The OH uses polarizing beam splitter-liquid crystal plate (PBS/LC assemblies to perform reconfigurable beam combination functions. The properties of the OH make it suitable for embedding complex network topologies such as completed connected mesh or hypercube. This paper proposes the use of rapid prototyping technology for implementing an optomechanical system suitable for studying the reconfigurable characteristics of a free-space optical channel. Additionally, it reports how the limited contrast ratio of the optical components can affect the attenuation of the optical signal and the crosstalk caused by misdirected signals. Different techniques are also proposed in order to increase the optical modulation amplitude (OMA of the system.

  20. Modeling paraxial wave propagation in free-electron laser oscillators

    NARCIS (Netherlands)

    Karssenberg, J.G.; van der Slot, Petrus J.M.; Volokhine, I.; Verschuur, Jeroen W.J.; Boller, Klaus J.

    2006-01-01

    Modeling free-electron laser (FEL) oscillators requires calculation of both the light-beam interaction within the undulator and the light propagation outside the undulator. We have developed a paraxial optical propagation code that can be combined with various existing models of gain media, for

  1. CAS CERN Accelerator School. Synchrotron radiation and free electron lasers. Proceedings

    International Nuclear Information System (INIS)

    Turner, S.

    1998-01-01

    These proceedings present the lectures given at the tenth specialised course organised by the CERN Accelerator School (CAS), the topic this time being 'Synchrotron Radiation and Free-electron Lasers'. A similar course was already given at Chester, UK in 1989 and whose proceedings were published as CERN 90-03. However, recent progress in this field has been so rapid that it became urgent to present a revised version of the course. Starting with a review of the characteristics of synchrotron radiation there follows introductory lectures on electron dynamics in storage rings, beam insertion devices, and beam current and radiation brightness limits. These themes are then developed with more detailed lectures on lattices and emittance, wigglers and undulators, current limitations, beam lifetime and quality, diagnostics and beam stability. Finally lectures are presented on linac and storage ring free-electron lasers. (orig.)

  2. Attosecond time-energy structure of X-ray free-electron laser pulses

    Science.gov (United States)

    Hartmann, N.; Hartmann, G.; Heider, R.; Wagner, M. S.; Ilchen, M.; Buck, J.; Lindahl, A. O.; Benko, C.; Grünert, J.; Krzywinski, J.; Liu, J.; Lutman, A. A.; Marinelli, A.; Maxwell, T.; Miahnahri, A. A.; Moeller, S. P.; Planas, M.; Robinson, J.; Kazansky, A. K.; Kabachnik, N. M.; Viefhaus, J.; Feurer, T.; Kienberger, R.; Coffee, R. N.; Helml, W.

    2018-04-01

    The time-energy information of ultrashort X-ray free-electron laser pulses generated by the Linac Coherent Light Source is measured with attosecond resolution via angular streaking of neon 1s photoelectrons. The X-ray pulses promote electrons from the neon core level into an ionization continuum, where they are dressed with the electric field of a circularly polarized infrared laser. This induces characteristic modulations of the resulting photoelectron energy and angular distribution. From these modulations we recover the single-shot attosecond intensity structure and chirp of arbitrary X-ray pulses based on self-amplified spontaneous emission, which have eluded direct measurement so far. We characterize individual attosecond pulses, including their instantaneous frequency, and identify double pulses with well-defined delays and spectral properties, thus paving the way for X-ray pump/X-ray probe attosecond free-electron laser science.

  3. Prediction of progression in patients with mild cognitive impairment using IMP-SPECT

    International Nuclear Information System (INIS)

    Okamura, Nobuyuki; Shinkawa, Mitsutoshi; Arai, Hiroyuki; Matsui, Toshifumi; Nakajo, Kazushi; Maruyama, Masahiro; Hu, Xia Sheng; Sasaki, Hidetada

    2000-01-01

    To examine the difference in functional brain imaging between mild cognitive impairment (MCI) and normal aging, we measured rCBF on functional brain imaging using 123 I-IMP single photon emission computed tomography (IMP-SPECT) in 19 MCI patients who progressed to develop AD on follow-up and 23 probable Alzheimer's disease (AD) patients as well as 15 age-matched normal subjects. Baseline MMSE score was 25.3 (SD 1.2) in the MCI group and 17.5 (SD 3.3) in the AD group. The regions of interest (ROI) in the posterior cingulate gyrus, frontal, temporal and parietal cortices were drawn on the image of IMP-SPECT with reference to an individual MRI image. The rCBF ratio was calculated using ROI value in the cerebellum as a reference. Voxel-based analysis was also preformed using statistical parametric mapping (SPM). The rCBF ratio in the posterior cingulate gyrus was significantly reduced in the MCI group (mean 0.956, SD 0.080) and the AD group (mean 0.833, SD 0.118) compared to that in the normal group (mean 1.083, SD 0.084). In the frontal, temporal and parietal cortices, the rCBF ratio was significantly reduced only in the AD group compared to the normal group. At a fixed specificity of 80%, the diagnostic sensitivity in the discrimination between MCI patients and normal subjects was 80.5% when using rCBF ratio in posterior cingulate gyrus. In the SPM analysis, significant reduction of the rCBF in MCI group was observed only in the posterior cingulate gyrus, compared with normal subject group. Our results suggest that MCI patients presenting with a posterior cingulate hypoperfusion are at higher risk for transition from MCI to clinically recognizable AD. (author)

  4. An extreme ultraviolet Michelson interferometer for experiments at free-electron lasers

    International Nuclear Information System (INIS)

    Hilbert, Vinzenz; Fuchs, Silvio; Paulus, Gerhard G.; Zastrau, Ulf; Blinne, Alexander; Feigl, Torsten; Kämpfer, Tino; Rödel, Christian; Uschmann, Ingo; Wünsche, Martin; Förster, Eckhart

    2013-01-01

    We present a Michelson interferometer for 13.5 nm soft x-ray radiation. It is characterized in a proof-of-principle experiment using synchrotron radiation, where the temporal coherence is measured to be 13 fs. The curvature of the thin-film beam splitter membrane is derived from the observed fringe pattern. The applicability of this Michelson interferometer at intense free-electron lasers is investigated, particularly with respect to radiation damage. This study highlights the potential role of such Michelson interferometers in solid density plasma investigations using, for instance, extreme soft x-ray free-electron lasers. A setup using the Michelson interferometer for pseudo-Nomarski-interferometry is proposed

  5. An extreme ultraviolet Michelson interferometer for experiments at free-electron lasers.

    Science.gov (United States)

    Hilbert, Vinzenz; Blinne, Alexander; Fuchs, Silvio; Feigl, Torsten; Kämpfer, Tino; Rödel, Christian; Uschmann, Ingo; Wünsche, Martin; Paulus, Gerhard G; Förster, Eckhart; Zastrau, Ulf

    2013-09-01

    We present a Michelson interferometer for 13.5 nm soft x-ray radiation. It is characterized in a proof-of-principle experiment using synchrotron radiation, where the temporal coherence is measured to be 13 fs. The curvature of the thin-film beam splitter membrane is derived from the observed fringe pattern. The applicability of this Michelson interferometer at intense free-electron lasers is investigated, particularly with respect to radiation damage. This study highlights the potential role of such Michelson interferometers in solid density plasma investigations using, for instance, extreme soft x-ray free-electron lasers. A setup using the Michelson interferometer for pseudo-Nomarski-interferometry is proposed.

  6. Kinetic theory of free electron lasers

    Energy Technology Data Exchange (ETDEWEB)

    Hafizi, B. [Naval Research Lab., Washington, DC (United States); Roberson, C.W. [Office of Naval Research, Arlington, VA (United States)

    1995-12-31

    We have developed a relativistic kinetic theory of free electron lasers (FELs). The growth rate, efficiency, filling factor and radius of curvature of the radiation wave fronts are determined. We have used the theory to examine the effects of beam compression on growth rate. The theory has been extended to include self field effects on FEL operation. These effects are particularly important in compact, low voltage FELs. The surprising result is that the self field contribution to the beam quality is opposite to the emittance contribution. Hence self fields can improve beam quality, particularly in compact, low voltage FELs.

  7. On the applicability of nearly free electron model for resistivity calculations in liquid metals

    International Nuclear Information System (INIS)

    Gorecki, J.; Popielawski, J.

    1982-09-01

    The calculations of resistivity based on the nearly free electron model are presented for many noble and transition liquid metals. The triple ion correlation is included in resistivity formula according to SCQCA approximation. Two different methods for describing the conduction band are used. The problem of applicability of the nearly free electron model for different metals is discussed. (author)

  8. Absolute Hydration Free Energy of Proton from First Principles Electronic Structure Calculations

    International Nuclear Information System (INIS)

    Zhan, Chang-Guo; Dixon, David A.

    2001-01-01

    The absolute hydration free energy of the proton, DGhyd298(H+), is one of the fundamental quantities for the thermodynamics of aqueous systems. Its exact value remains unknown despite extensive experimental and computational efforts. We report a first-principles determination of DGhyd298(H+) by using the latest developments in electronic structure theory and massively parallel computers. DGhyd298(H+) is accurately predicted to be -262.4 kcal/mol based on high-level, first-principles solvation-included electronic structure calculations. The absolute hydration free energies of other cations can be obtained by using appropriate available thermodynamic data in combination with this value. The high accuracy of the predicted absolute hydration free energy of proton is confirmed by applying the same protocol to predict DGhyd298(Li+)

  9. An Electrostatic Free-Electron Maser for Fusion - Design Considerations

    NARCIS (Netherlands)

    van Amersfoort, P. W.; Urbanus, W. H.; Verhoeven, A. G. A.; Verheul, A.; Sterk, A. B.; Vaningen, A. M.; van der Wiel, M. J.

    1991-01-01

    For the next generation of large tokamaks, efficient mm-wave sources at frequencies of up to 300 GHz and unit size of 1 MW cw will be required. The design of a free electron maser for this application, based on a dc electrostatic accelerator, is discussed.

  10. First results of the CALICE SDHCAL technological prototype

    CERN Document Server

    Buridon, V.; Caponetto, L.; Ete, R.; Garillot, G.; Grenier, G.; Han, R.; Ianigro, J.C.; Kieffer, R.; Laktineh, I.; Lumb, N.; Mathez, H.; Mirabito, L.; Petrukhin, A.; Steen, A.; Antequera, J.Berenguer; Alamillo, E.Calvo; Fouz, M.C.; Marin, J.; Puerta-Pelayo, J.; Verdugo, A.; Cortina Gil, E.; Mannai, S.; Cauwenbergh, S.; Tytgat, M.; Pingault, A.; Zaganidis, N.; Anduze, M.; Balagura, V.; Belkadhi, K.; Boudry, V.; Brient, J-C.; Cornat, R.; Frotin, M.; Gastaldi, F.; Haddad, Y.; Ruan, M.; Shpak, K.; Videau, H.; Yu, D.; Callier, S.; Conforti di Lorenzo, S.; Dulucq, F.; Martin-Chassard, G.; de la Taille, Ch.; Raux, L.; Seguin-Moreau, N.; Boumediene, D.; Carloganu, C.; Francais, V.; Bonis, J.; Bouquet, B.; Cornebise, P.; Doublet, Ph.; Faucci-Giannelli, M.; Frisson, T.; Guilhem, G.; Li, H.; Richard, F.; Poschl, R.; Rouene, J.; Wicek, F.; Zhang, Z.; Deng, Z.; Li, Y.; Wang, Y.; Yue, Q.; Yang, Z.; Cho, G.; Kim, D-W.; Lee, S.C.; Park, W.; Vallecorsa, S.; Brianne, E.; Ebrahimi, A.; Gadow, K.; Gottlicher, P.; Gunter, C.; Hartbrich, O.; Hermberg, B.; Irles, A.; Krivan, F.; Kruger, K.; Kvasnicka, J.; Lu, S.; Lutz, B.; Morgunov, V.; Provenza, A.; Reinecke, M.; Sefkow, F.; Schuwalow, S.; Tran, H.L.; Garutti, E.; Laurien, S.; Matysek, M.; Ramilli, M.; Schroeder, S.; Bilki, B.; Norbeck, E.; Northacker, D.; Onel, Y.; Kirikova, N.; Kozlov, V.; Smirnov, P.; Soloviev, Y.; Chadeeva, M.; Danilov, M.; Gabriel, M.; Goecke, P.; Kiesling, C.; van der Kolk, N.; Simon, F.; Soldner, C.; Szalay, M.; Weuste, L.; Jeans, D.; Komamiya, S.; Nakanishi, H.; Benchekroun, D.; Hoummada, A.; Khoulaki, Y.

    2016-04-01

    The CALICE Semi-Digital Hadronic Calorimeter (SDHCAL) prototype, built in 2011, was exposed to beams of hadrons, electrons and muons in two short periods in 2012 on two different beam lines of the CERN SPS. The prototype with its 48 active layers, made of Glass Resistive Plate Chambers and their embedded readout electronics, was run in triggerless and power-pulsing mode. The performance of the SDHCAL during the test beam was found to be very satisfactory with an efficiency exceeding 90% for almost all of the 48 active layers. A linear response (within 5%) and a good energy resolution are obtained for a large range of hadronic energies (5-80GeV) by applying appropriate calibration coefficients to the collected data for both the Digital (Binary) and the Semi-Digital (Multi-threshold) modes of the SDHCAL prototype. The Semi-Digital mode shows better performance at energies exceeding 30GeV

  11. Performance of prototype segmented CdZnTe arrays

    International Nuclear Information System (INIS)

    Parsons, A.; Palmer, D.M.; Kurczynski, P.; Barbier, L.; Barthelmy, S.; Bartlett, L.; Gehrels, N.; Krizmanic, J.; Stahle, C.M.; Tueller, J.; Teegarden, B.

    1998-01-01

    The Burst and All Sky Imaging Survey (BASIS) is a proposed mission to provide ∼3 arc second locations of approximately 90 Gamma-Ray Bursts (GRBs) per year. The BASIS coded aperture imaging system requires a segmented detector plane able to detect the interaction position of (10--150 keV) photons to less than 100 microm. To develop prototype detector arrays with such fine position resolution the authors have fabricated many 15 mm x 15 mm x 2 mm 100 microm pitch CdZnTe strip detectors. They have assembled these fine pitch CdZnTe strip detectors into prototype 2 x 2 and 6 x 6 element arrays read out by ASIC electronics. The assembly and electronics readout of the 6 x 6 flight prototype array will be discussed, and preliminary data illustrating the uniformity and efficiency of the array will be presented

  12. Coproduction of KPC-2 and IMP-10 in Carbapenem-Resistant Serratia marcescens Isolates from an Outbreak in a Brazilian Teaching Hospital.

    Science.gov (United States)

    Silva, Kesia Esther; Cayô, Rodrigo; Carvalhaes, Cecilia Godoy; Patussi Correia Sacchi, Flávia; Rodrigues-Costa, Fernanda; Ramos da Silva, Ana Carolina; Croda, Julio; Gales, Ana Cristina; Simionatto, Simone

    2015-07-01

    We describe an outbreak caused by KPC-2- and IMP-10-producing Serratia marcescens isolates in a Brazilian teaching hospital. Tigecycline was the only active antimicrobial agent tested. The blaIMP-10 gene was located in a new class 1 integron, named In990, carried by a nonconjugative plasmid, in contrast to blaKPC-2. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  13. The prototype triggerless data acquisition of the PANDA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Milan; Reiter, Simon; Lange, Soeren; Kuehn, Wolfgang [II. Physikalisches Institut, Giessen Univ. (Germany); Collaboration: PANDA-Collaboration

    2016-07-01

    The PANDA detector will operate with a very high interaction rate of up to 20 MHz, in a free streaming mode without hardware trigger. Data filtering will be performed by complete online event reconstruction with a highly parallelized farm of FPGAs as first level and on a farm of GPUs or PCs as a second level. The requirement is a background reduction by a factor of >1000. A prototype trigger-less data acquisition (PTDAQ) system for the detector validation measurements comprises free streaming and synchronization readout, for event building and filtering has been developed. A first in beam environment test was performed at the Mainzer Mikrotron, reading out the barrel electromagnetic calorimeter prototype (Proto120).

  14. An ergonomics prototype of adjustable chin stands aid for visual mechanical inspection at electronic manufacturing-based company in Kuantan, Malaysia

    Science.gov (United States)

    Elias, Nurainaa; Mat Yahya, Nafrizuan

    2018-04-01

    Chin stands aid is a device designed to reduce fatigue on the chin during the Visual Mechanical Inspection (VMI) task for operators in TT Electronic Sdn Bhd, Kuantan, Malaysia. It is also used to reduce cycle time and also improve employee well-being in terms of comfort. In this project, a 3D model of chin stands aid with an ergonomics approach is created using SOLIDWORKS software. Two different concepts were designed and the best one is chosen based on the Pugh concept selection method, concept screening and also concept scoring. After the selection of concepts is done, a prototype of chin stands aid will be developed and a simulation of the prototype is performed. The simulation has been executed by using Workbench ANSYS software as a tool. Stress analysis, deformation analysis, and fatigue analysis have been done to know the strength and lifespan of the product. The prototype also has been tested to know the functionality and also comfortability for the user to use the chin stands aid.

  15. Hydrologic design methodologies for small-scale hydro at ungauged sites. Phase 2A, British Columbia. Primer for Integrated Method for Power Analysis (IMP)

    Energy Technology Data Exchange (ETDEWEB)

    1986-01-01

    This report provides a user's manual for the Integrated Method for Power Analysis (IMP) series of programs, developed to aid in evaluating small-scale hydroelectric power sites in British Columbia. The primary objective of IMP is to address the problem posed by hydroelectric development at sites completely lacking in streamflow records. The province's mountainous terrain, with numerous microclimates, precluded methods of regional analysis based on regression or comparisons with gauged streams; instead, a conceptual model of physical processes on the land and in the atmosphere was used as a basis for developing IMP. The IMP package consists of five basic components: an atmospheric model of annual precipitation and 1-in-10-year 24-h maximum rainfall; a watershed model that will generate a daily series of streamflow data; a flood frequency analysis system that uses site-specific topographical information and information from the atmospheric model to generate the flood frequency curve; a hydroelectric power simulation program which determines the daily energy output for a run-of-river or reservoir storage site; and a graphics analysis package which provides direct visualization of atmospheric and streamflow data, and the results of watershed and power simulation modelling. Within each component of the program, the program requirements and capabilities are discussed. A series of sample screens are shown, illustrating the use of the IMP package for a particular simulation. 18 figs., 2 tabs.

  16. Synchronization and sequencing of data acquisition and control electronics at the European X-ray free electron laser

    International Nuclear Information System (INIS)

    Gessler, Patrick

    2015-11-01

    The 3.5 km long European X-Ray Free Electron Laser, currently under construction in northern Germany, will deliver bursts of up to 2700 short X-ray pulses every 100 ms, providing wavelengths between 0.05 and 6 nm, and a repetition rate of 4.5 MHz to several experiment stations. It allows in-depth research in various scientific fields. In order to set-up the beam, position samples and capture the measured variables, information from the accelerator, diagnostic devices and detectors have to be digitized, converted, processed, transferred, concentrated, distributed, reorganized, controlled and saved. All these steps have to be accurately synchronized and sequenced relative to the actual electron bunch or photon pulse in order to guarantee correct data acquisition timings and unique identification of each bunch passing the beamlines. This document provides a complete description of the planning, design, realization and evaluation of the European XFEL Timing System, which implements the synchronization and sequencing of the data acquisition and control electronics for the European X-Ray Free-Electron Laser Facility.

  17. Evaluation of umami taste in mushroom extracts by chemical analysis, sensory evaluation, and an electronic tongue system.

    Science.gov (United States)

    Phat, Chanvorleak; Moon, BoKyung; Lee, Chan

    2016-02-01

    Seventeen edible mushrooms commercially available in Korea were analysed for their umami taste compounds (5'-nucleotides: AMP, GMP, IMP, UMP, XMP; free amino acids: aspartic, glutamic acid) and subjected to human sensory evaluation and electronic tongue measurements. Amanita virgineoides featured the highest total 5'-nucleotide content (36.9 ± 1.50 mg/g), while monosodium glutamate-like components (42.4 ± 6.90 mg/g) were highest in Agaricus bisporus. The equivalent umami concentration (EUC) ranged from 1.51 ± 0.42 to 3890 ± 833 mg MSG/g dry weight; most mushrooms exhibited a high umami taste. Pleurotus ostreatus scored the highest in the human sensory evaluation, while Flammulina velutipes obtained the maximum score in the electronic tongue measurement. The EUC and the sensory score from the electronic tongue test were highly correlated, and also showed significant correlation with the human sensory evaluation score. These results suggest that the electronic tongue is suitable to determine the characteristic umami taste of mushrooms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Microbunching-instability-induced sidebands in a seeded free-electron laser

    Directory of Open Access Journals (Sweden)

    Zhen Zhang

    2016-05-01

    Full Text Available Measurements of the multishot-averaged, soft x-ray, self-seeding spectrum at the LCLS free-electron laser often have a pedestal-like distribution around the seeded wavelength, which limits the spectral purity and can negatively affect some user applications not employing a post-undulator monochromator. In this paper, we study the origins of such pedestals, focusing on longitudinal phase space modulations produced by the microbunching instability upstream of the free-electron laser (FEL undulator. We show from theory and numerical simulation that both energy and density modulations can induce sidebands in a high-gain, seeded FEL whose fractional strength typically grows as the square of the undulator length. The results place a tight constraint on the longitudinal phase space uniformity of the electron beam for a seeded FEL, possibly requiring the amplitude of long-wavelength modulations to be much smaller than the typical incoherent energy spread if the output sideband power is to remain only a couple percent or less of the amplified seed power.

  19. Predominance of carbapenem-resistant Pseudomonas aeruginosa isolates carrying blaIMP and blaVIM metallo-β-lactamases in a major hospital in Costa Rica.

    Science.gov (United States)

    Toval, Francisco; Guzmán-Marte, Anel; Madriz, Vivian; Somogyi, Teresita; Rodríguez, César; García, Fernando

    2015-01-01

    This study aimed to assess the molecular basis of the resistance to carbapenems in clinical isolates of Pseudomonas aeruginosa recovered from a tertiary-level health facility in San José, Costa Rica. A total of 198 non-duplicated isolates were evaluated for their susceptibility to β-lactams, aminoglycosides and fluoroquinolones. The production of metallo-β-lactamases (MBLs), the presence of MBL encoding genes (blaIMP, blaVIM and blaGIM-1) and the occurrence of these genes within class 1 integrons were investigated. In addition, an ERIC2 PCR fingerprinting method was used to elucidate the distribution of the detected MBL genes within the strain collection. Of the 198 isolates tested, 125 (63.1 %) were categorized as carbapenem-resistant. The majority (88.8 %) of the carbapemen-resistant isolates also showed resistance to ceftazidime, cefepime, aztreonam, ticarcillin/clavulanic acid, amikacin, gentamicin, tobramycin, ciprofloxacin and gatifloxacin. Among the carbapenem-resistant isolates, 102 (81.6 %) showed MBL activity. Strikingly, both blaIMP and blaVIM genes were simultaneously detected in most (94.1 %) of the 102 MBL producers. Five carbapenem-resistant MBL producers were positive only for blaIMP genes. Almost 70 % of the isolates examined harboured the intI1 gene, accompanied by the sul1 and qacEΔ1 genes in 136 (99 %) and 122 (89 %) isolates, respectively. The majority (94.4 %) of the carbapenem-resistant isolates carried the intI1 gene, in contrast to 26 % of the carbapenem-susceptible isolates. Ninety-three out of 96 (96.9 %) isolates carrying both blaIMP and blaVIM genes also harboured the intI1, sul1 and qacEΔ1 genes. Gene cassettes from carbapenem-susceptible and MBL-negative carbapenem-resistant isolates encoded aminoglycoside-resistance enzymes (aadA2, aadA4 and aadA6) as well as orfD and qacF genes. RAPD analysis distributed 126 of the isolates in 29 clusters. Eighty of the 90 blaIMP (+) blaVIM (+) isolates were sorted into 16

  20. First microwave generation in the FOM free-electron maser

    NARCIS (Netherlands)

    Verhoeven, A. G. A.; Bongers, W. A.; Bratman, V. L.; Caplan, M.; Denisov, G. G.; van der Geer, C. A. J.; Manintveld, P.; Poelman, A. J.; Pluygers, J.; Shmelyov, M. Y.; Smeets, P. H. M.; Sterk, A. B.; Urbanus, W. H.

    1998-01-01

    A free-electron maser (FEM) has been built as a pilot experiment for a millimetre-wave source for applications on future fusion research devices such as ITER, the International Tokamak Experimental Reactor. A unique feature of the Dutch fusion FEM is the possibility to tune the frequency over the

  1. Cerebral blood flow measurement using 123I-IMP graph plot method with SPECT. Comparison with autoradiography method

    International Nuclear Information System (INIS)

    Shinohara, Yuki; Kamitani, Hideki; Ishibashi, Minako; Ito, Satoru; Ogawa, Toshihide

    2011-01-01

    The purpose of this study was to evaluate quantification of cerebral blood flow (CBF) values using 123 I-iodoamphetamine (IMP) graph plot (GP) method with single photon emission computed tomography (SPECT), compared with autoradiography (ARG) method. IMP-SPECT by GP combined with ARG method at rest was performed in 40 patients to determine the equation of linear regression for GP method in our institution. In addition, we compared regional CBF (rCBF) values at rest between GP and ARG methods in 10 other patients. Among all 50 patients, acetazolamide (ACZ)-challenged SPECT by GP combined with ARG method using 2-day protocol was performed in 10 patients. We also compared the rCBF values after ACZ challenge between GP and ARG methods in these 10 patients. The equation of linear regression for GP method in our institution was y=1.945x+20.36 (R 2 =0.586, P 2 =0.624, P 2 =0.150, P<0.001). IMP-SPECT by GP method at rest is useful to measure reliable rCBF values without arterial blood sampling, although we need pay attention to interpret the result of 2-day protocol ACZ-challenged SPECT by GP method. (author)

  2. Self-amplified spontaneous emission free electron laser devices and nonideal electron beam transport

    Directory of Open Access Journals (Sweden)

    L. L. Lazzarino

    2014-11-01

    Full Text Available We have developed, at the SPARC test facility, a procedure for a real time self-amplified spontaneous emission free electron laser (FEL device performance control. We describe an actual FEL, including electron and optical beam transport, through a set of analytical formulas, allowing a fast and reliable on-line “simulation” of the experiment. The system is designed in such a way that the characteristics of the transport elements and the laser intensity are measured and adjusted, via a real time computation, during the experimental run, to obtain an on-line feedback of the laser performances. The detail of the procedure and the relevant experimental results are discussed.

  3. Optical synchronization of a free-electron laser with femtosecond precision

    International Nuclear Information System (INIS)

    Loehl, F.

    2009-09-01

    High-gain free-electron lasers (FELs) are capable of generating sub-10 fs long light pulses. In order to take full advantage of these extremely short light pulses in time-resolved experiments, synchronization with a so far unprecedented timing accuracy is required. Within this thesis, an optical synchronization system providing sub-10 fs stability has been developed and was implemented at the ultra-violet and soft X-ray free-electron laser FLASH at DESY, Hamburg. The system uses a mode-locked laser as a timing reference. The laser pulses are distributed via length stabilized optical fiber-links to the remote locations. A key feature of the system is a bunch arrival-time monitor detecting the electron bunch arrival-time with an unrivaled resolution of 6 fs. A feedback system based on the arrival-time monitor was established, improving the arrival-time fluctuations from 200 fs in the unstabilized case to 25 fs with active feedback. In order to achieve the high peak current of several thousand amperes required for the FEL process, the electron bunches are longitudinally compressed in two magnetic chicanes. A second feedback system was developed stabilizing the bunch compression process based on measurements of diffraction radiation. The combination of both feedback systems improves the stability of the FEL radiation significantly. (orig.)

  4. Optical synchronization of a free-electron laser with femtosecond precision

    Energy Technology Data Exchange (ETDEWEB)

    Loehl, F.

    2009-09-15

    High-gain free-electron lasers (FELs) are capable of generating sub-10 fs long light pulses. In order to take full advantage of these extremely short light pulses in time-resolved experiments, synchronization with a so far unprecedented timing accuracy is required. Within this thesis, an optical synchronization system providing sub-10 fs stability has been developed and was implemented at the ultra-violet and soft X-ray free-electron laser FLASH at DESY, Hamburg. The system uses a mode-locked laser as a timing reference. The laser pulses are distributed via length stabilized optical fiber-links to the remote locations. A key feature of the system is a bunch arrival-time monitor detecting the electron bunch arrival-time with an unrivaled resolution of 6 fs. A feedback system based on the arrival-time monitor was established, improving the arrival-time fluctuations from 200 fs in the unstabilized case to 25 fs with active feedback. In order to achieve the high peak current of several thousand amperes required for the FEL process, the electron bunches are longitudinally compressed in two magnetic chicanes. A second feedback system was developed stabilizing the bunch compression process based on measurements of diffraction radiation. The combination of both feedback systems improves the stability of the FEL radiation significantly. (orig.)

  5. Free-Electron Lasers Push Into New Frontiers

    International Nuclear Information System (INIS)

    Benson, Stephen V.

    2003-01-01

    From the early days of the development of free-electron lasers (FELs) the promise of high power and short wavelengths has tantalized physicists and other scientists. Recent developments in accelerator technologies and some new discoveries about the physics of FELs have allowed researchers to push the performance of FELs into new frontiers of high power, short wavelength, and ultra-short pulses. Spin-offs from the FELs have also opened up new radiation sources in the THz, X-ray and gamma ray wavelength ranges

  6. 123I-IMP SPECT studies in schizophrenia and atypical psychosis

    International Nuclear Information System (INIS)

    Hayashi, Takuji; Suga, Hidemichi

    1993-01-01

    According to the classification of Mitsuda, 23 patients with endogenous psychosis aged 40 years or younger, presenting with hallucination and delusion, were classified as having schizophrenia (n=12) or atypical psychosis (n=11). These patients were studied by single photon emission computed tomography (SPECT) with N-isopropyl-p-I-123-iodoamphetamine (I-123 IMP). Sixteen healthy persons served as controls. Early and delayed SPECT images were obtained 30 min and 4 hr, respectively, after intravenous injection of I-123 IMP. The group of schizophrenic patients had markedly decreased uptake of I-123 in the basal ganglia, as well as the right temporal and left occipital areas on both early and delayed images. In the group of atypical psychosis patients, however, decreased uptake of I-123 was noted in both the right basal ganglia and left occipital area on early images, but none of such findings were seen on delayed images. Regarding the uptake ratio in the frontal area on both early and delayed images, there were significant differences between the two groups. These findings have important implications for the different etiology of both disease types: not only functional disturbance in the frontal area but also irreversible changes may be involved in the occurrence of schizophrenia, and functional disturbance particularly in the right basal ganglia may be involved in the occurrence of atypical psychosis. (N.K.)

  7. 6. Seminar of the IIE-ININ-IMP on technological specialties. Topic 7: energy savings

    International Nuclear Information System (INIS)

    1992-01-01

    The document includes 6 papers presented at the 6. Seminar of the IIE-ININ-IMP (Mexico) on technological specialties in the field of energy savings. (Topic 7). One item was in INIS subject scope and a separate abstract was prepared for it

  8. Characterization and control of femtosecond electron and X-ray beams at free-electron lasers

    International Nuclear Information System (INIS)

    Behrens, Christopher

    2012-11-01

    X-ray free-electron lasers (FELs) open up new frontiers in photon science, and in order to take full advantage of these unique accelerator-based light sources, the characterization and control of the femtosecond electron and X-ray beams is essential. Within this cumulative thesis, recent results achieved within the active research field of femtosecond electron and X-ray beams at FELs are reported.The basic principles of X-ray FELs are described, and concepts of longitudinal electron beam diagnostics with femtosecond accuracy are covered. Experimental results obtained with a transverse deflecting structure (TDS) and spectroscopy of coherent terahertz radiation are presented, and the suppression of coherent optical radiation effects, required for diagnostics utilizing a TDS, is demonstrated. Control of the longitudinal phase space by using multiple radio frequencies for longitudinal electron beam tailoring is presented, and a new technique of reversible electron beam heating with two TDSs is described. For the characterization of femtosecond X-ray pulses, a novel method based on dedicated longitudinal phase space diagnostics for electron beams is introduced, and recent measurements with a streaking technique using external terahertz fields are presented.

  9. Characterization and control of femtosecond electron and X-ray beams at free-electron lasers

    Energy Technology Data Exchange (ETDEWEB)

    Behrens, Christopher

    2012-11-15

    X-ray free-electron lasers (FELs) open up new frontiers in photon science, and in order to take full advantage of these unique accelerator-based light sources, the characterization and control of the femtosecond electron and X-ray beams is essential. Within this cumulative thesis, recent results achieved within the active research field of femtosecond electron and X-ray beams at FELs are reported.The basic principles of X-ray FELs are described, and concepts of longitudinal electron beam diagnostics with femtosecond accuracy are covered. Experimental results obtained with a transverse deflecting structure (TDS) and spectroscopy of coherent terahertz radiation are presented, and the suppression of coherent optical radiation effects, required for diagnostics utilizing a TDS, is demonstrated. Control of the longitudinal phase space by using multiple radio frequencies for longitudinal electron beam tailoring is presented, and a new technique of reversible electron beam heating with two TDSs is described. For the characterization of femtosecond X-ray pulses, a novel method based on dedicated longitudinal phase space diagnostics for electron beams is introduced, and recent measurements with a streaking technique using external terahertz fields are presented.

  10. First results of the CALICE SDHCAL technological prototype

    International Nuclear Information System (INIS)

    2016-01-01

    The CALICE Semi-Digital Hadronic Calorimeter (SDHCAL) prototype, built in 2011, was exposed to beams of hadrons, electrons and muons in two short periods in 2012 on two different beam lines of the CERN SPS. The prototype with its 48 active layers, made of Glass Resistive Plate Chambers and their embedded readout electronics, was run in triggerless and power-pulsing mode. The performance of the SDHCAL during the test beam was found to be very satisfactory with an efficiency exceeding 90% for almost all of the 48 active layers. A linear response (within ± 5%) and a good energy resolution are obtained for a large range of hadronic energies (5–80 GeV) by applying appropriate calibration coefficients to the collected data for both the Digital (Binary) and the Semi-Digital (Multi-threshold) modes of the SDHCAL prototype. The Semi-Digital mode shows better performance at energies exceeding 30 GeV

  11. PREFACE: XXVIII International Conference on Photonic, Electronic and Atomic Collisions (ICPEAC 2013)

    Science.gov (United States)

    Xiao, Guoqing; Cai, Xiaohong; Ding, Dajun; Ma, Xinwen; Zhao, Yongtao

    2014-04-01

    The 28th International Conference on Photonic, Electronic and Atomic Collisions (XXVIII ICPEAC) was held by the Institute of Modern Physics, Chinese Academy of Sciences (IMP) on 24-30 July, 2013 in Lanzhou, China. The 444 conference participants came from 37 countries and/or regions. Five plenary lectures, more than 80 progress reports and special reports had been arranged according to the decision of the ICPEAC International General Committee. Meanwhile, more than 650 abstracts were selected as poster presentations. Before the conference, three highly distinguished scientists, Professor Joachim Burgdöorfer, Professor Hossein Sadeghpour and Professor Yasunori Yamazaki, presented tutorial lectures with the support of the IMP Branch of Youth Innovation Promotion Association, CAS (IMP-YIPA). During the conference, Professor Jianwei Pan from University of Sciences and Technology in China presented an enlightening public lecture on quantum communication. Furthermore, 2013 IUPAP Young Scientist Prize was awarded to Dr T Jahnke from Johann Wolfgang Goethe University of Germany. The Sheldon Datz Prize for an Outstanding Young Scientist Attending ICPEAC was awarded to Dr Diogo Almeida from University of Fribourg of Switzerland. As a biannual academic conference, ICPEAC is one of the most important international conferences on atomic and molecular physics. The topic of the conference covers the recent progresses in photonic, electronic, atomic, ionic, molecular, cluster collisions with matter. With a history back to 1958, ICPEAC came to China for the very first time. IMP has been preparing the conference six years before, ever since the ICPEAC International General Committee made the decision to hold the XXVIII ICPEAC in Lanzhou. This proceedings includes the papers of the two plenary lectures, 40 progress reports, 17 special reports and 337 posters, which were reviewed and revised according to the comments of the referees. The Local Organizing Committee would like to

  12. Introduction to free electron lasers (1/3)

    CERN Multimedia

    CERN. Geneva

    2002-01-01

    The Free-electron laser (FEL) is a source of coherent electromagnetic radiation based on a relativistic electron beam. First operated 25 years ago, the FEL has now reached a stage of maturity for operation in the infra-red region of the spectrum and several facilities provide intense FEL radiation beams for research covering a wide range of disciplines. Several projects both underway and proposed aim at pushing the minimum wavelength from its present limit around 100 nm progressively down to the 1 Angstrom region where the X-ray FEL would open up many new and exciting research possibilities. Other developments aim at increasing power levels to the 10's of kW level. In this series of lectures we give an introduction to the basic principles of FELs and their different modes of operation, and summarise their applications and current state of development.

  13. Introduction to free electron lasers (3/3)

    CERN Multimedia

    CERN. Geneva

    2002-01-01

    The Free-electron laser (FEL) is a source of coherent electromagnetic radiation based on a relativistic electron beam. First operated 25 years ago, the FEL has now reached a stage of maturity for operation in the infra-red region of the spectrum and several facilities provide intense FEL radiation beams for research covering a wide range of disciplines. Several projects both underway and proposed aim at pushing the minimum wavelength from its present limit around 100 nm progressively down to the 1 Angstrom region where the X-ray FEL would open up many new and exciting research possibilities. Other developments aim at increasing power levels to the 10's of kW level. In this series of lectures we give an introduction to the basic principles of FELs and their different modes of operation, and summarise their applications and current state of development.

  14. Introduction to free electron lasers (2/3)

    CERN Multimedia

    CERN. Geneva

    2002-01-01

    The Free-electron laser (FEL) is a source of coherent electromagnetic radiation based on a relativistic electron beam. First operated 25 years ago, the FEL has now reached a stage of maturity for operation in the infra-red region of the spectrum and several facilities provide intense FEL radiation beams for research covering a wide range of disciplines. Several projects both underway and proposed aim at pushing the minimum wavelength from its present limit around 100 nm progressively down to the 1 Angstrom region where the X-ray FEL would open up many new and exciting research possibilities. Other developments aim at increasing power levels to the 10's of kW level. In this series of lectures we give an introduction to the basic principles of FELs and their different modes of operation, and summarise their applications and current state of development.

  15. The free electron laser: conceptual history

    International Nuclear Information System (INIS)

    Madey, John; Scully, Marlan O; Sprangle, Phillip

    2016-01-01

    The free electron laser (FEL) has lived up to its promise as given in (Madey 1971 J. Appl. Phys. 42 1906) to wit: ‘As shall be seen, finite gain is available …from the far-infrared through the visible region …with the further possibility of partially coherent radiation sources in the x-ray region’. In the present paper we review the history of the FEL drawing liberally (and where possible literally) from the original sources. Coauthors, Madey, Scully and Sprangle were involved in the early days of the subject and give a first hand account of the subject with an eye to the future. (invited comment)

  16. A contact-free respiration monitor for smart bed and ambulatory monitoring applications.

    Science.gov (United States)

    Hart, Adam; Tallevi, Kevin; Wickland, David; Kearney, Robert E; Cafazzo, Joseph A

    2010-01-01

    The development of a contact-free respiration monitor has a broad range of clinical applications in the home and hospital setting. Current approaches suffer from a variety of problems including unreliability, low sensitivity, and high cost. This work describes a novel approach to contact-free respiration monitoring that addresses these shortcomings by employing a highly sensitive capacitance sensor to detect variations in capacitive coupling caused by breathing. A prototype system consisting of a synthetic-metallic pad, sensor electronics, and iPhone interface was built and its performance compared experimentally to the gold standard technique (Respiratory Inductance Plethysmography) on both a healthy volunteer and SimMan robotic mannequin. The prototype sensor effectively captured respiratory movements over breathing rates of 5-55 bpm; achieving an average spectral correlation of 0.88 (CI: 0.86-0.90) and 0.95 (CI: 0.95-0.96) to the gold standard using the SimMan and healthy volunteer respectively.

  17. Low power microwave tests on RF gun prototype of the Iranian Light Source Facility

    Directory of Open Access Journals (Sweden)

    A Sadeghipanah

    2017-08-01

    Full Text Available In this paper, we introduce RF electron gun of Iranian Light Source Facility (ILSF pre-injection system. Design, fabrication and low-power microwave tests results of the prototype RF electron gun have been described in detail. This paper also explains the tuning procedure of the prototype RF electron gun to the desired resonant frequency. The outcomes of this project brighten the path to the fabrication of the RF electron gun by the local industries  

  18. The effects of field errors on low-gain free-electron lasers

    International Nuclear Information System (INIS)

    Esarey, E.; Tang, C.M.; Marable, W.P.

    1991-01-01

    This paper reports on the effects of random wiggler magnetic field errors on low-gain free-electron lasers that are examined analytically and numerically through the use of ensemble averaging techniques. Wiggler field errors perturb the electron beam as it propagates and lead to a random walk of the beam centroid δx, variations in the axial beam energy δ γz and deviations in the relative phase of the electrons in the ponderomotive wave δψ. In principle, the random walk may be kept as small as desired through the use of transverse focusing and beam steering. Transverse focusing of the electron beam is shown to be ineffective in reducing the phase deviation. Furthermore, it is shown that beam steering at the wiggler entrance reduces the average phase deviation at the end of the wiggler by 1/3. The effect of the field errors (via the phase deviation) on the gain in the low-gain regime is calculated. To avoid significant reduction in gain it is necessary for the phase deviation to be small compared to 2π. The detrimental effects of wiggler errors on low-gain free-electron lasers may be reduced by arranging the magnet poles in an optimal ordering such that the magnitude of the phase deviation is minimized

  19. One-dimensional free-electron laser equations without the slowly varying envelope approximation

    Directory of Open Access Journals (Sweden)

    C. Maroli

    2011-07-01

    Full Text Available A set of one-dimensional equations has been deduced in the time domain from the Maxwell-Lorentz system with the aim of describing the free-electron laser radiation without using the slowly varying envelope approximation (SVEA. These equations are valid even in the case of arbitrarily short electron bunches and of current distributions with ripples on the scale of or shorter than the wavelength. Numerical examples are presented, showing that for long homogeneous bunches the new set of equations gives results in agreement with the SVEA free-electron laser theory and that the use of short or prebunched electron beams leads to a decrease of the emission lethargy. Furthermore, we demonstrate that in all cases in which the backward low frequency wave has negligible effects, these equations can be reduced to a form similar to the usual 1D SVEA equations but with a different definition of the bunching term.

  20. Design and Analysis of an Electron Gun/Booster and Free Electron Laser Optical Theory

    Science.gov (United States)

    2010-09-01

    105 65. Stanford DC gun equipotentials . . . . . . . . . . . . . . . . . . . . . . 106 66. Energy plots for various electrode ratios...222 121. Graphical Cross-correlation Demonstration . . . . . . . . . . . . . . . . 223 122. 2D cross-correlation surface ...them enough energy to escape the metal’s surface . Once free of the metal, the electric field accelerates the electrons toward an anode. If the anode is

  1. 7. Seminar of the IIE-ININ-IMP on technological specialties. Topic 10: Information Services

    International Nuclear Information System (INIS)

    1994-01-01

    The document includes 10 papers presented at the 7. Seminar of the IIE-IMP-ININ (Mexico) on technological specialities in the field of information services (Topic 10). Three items were in INIS subject scope and a separate abstract was prepared for each of them

  2. 6. Seminar of the IIE-ININ-IMP on technological specialties. Topic 13: earth sciences

    International Nuclear Information System (INIS)

    1992-01-01

    The document includes 12 papers presented at the 6. Seminar of the IIE-ININ-IMP (Mexico) on technological specialties in the field of earth sciences. (Topic 13). Four items were in INIS subject scope and a separate abstract was prepared for each of them

  3. Impôts, taxes et équité entre les sexes : codes, comportements et ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    6 déc. 2010 ... On sait que les impôts et la taxation peuvent favoriser l'égalité socioéconomique, mais ... Analysis of Direct and Indirect Taxes in Developing and Developed Countries. ... Gender and taxation in South Africa: a policy brief.

  4. Elevated expression of the IGF2 mRNA binding protein 2 (IGF2BP2/IMP2) is linked to short survival and metastasis in esophageal adenocarcinoma

    OpenAIRE

    Barghash, Ahmad; Golob-Schwarzl, Nicole; Helms, Volkhard; Haybaeck, Johannes; Kessler, Sonja M.

    2016-01-01

    Esophageal adenocarcinoma (EAC) represents the sixth leading cause of cancer-related deaths and develops in Barret's esophagus affected tissues. The IGF2 mRNA binding protein IMP2/IGF2BP2/p62 was originally identified as an autoantigen in hepatocellular carcinoma. Aim of this study was to investigate the expression and prognostic role of IMP2 in EAC. Human EAC and Barret's esophagus tissue showed overexpression of IMP2, particularly in tumors of increased size and in metastatic tissues. Molec...

  5. Pulse propagation in tapered wiggler free electron lasers

    International Nuclear Information System (INIS)

    Goldstein, J.C.; Colson, W.B.

    1981-01-01

    The one-dimensional theory of short pulse propagation in free electron lasers is extended to tapered wiggler devices and is used to study the behavior of an oscillator with parameter values close to those expected in forthcoming experiments. It is found that stable laser output is possible only over a small range of optical cavity lengths. Optical pulse characteristcs are presented and are found to change considerably over this range

  6. Clinical experience of [sup 123]I-IMP scintigraphy in detecting vertebral bone metastases of hepatocellular carcinoma. A comparison with bone scintigraphy with [sup 99m]Tc-MDP

    Energy Technology Data Exchange (ETDEWEB)

    Suto, Y. (Dept. of Radiology, Tottori Univ. Faculty of Medicine, Yonago (Japan) Dept. of Radiology, Matsue City Hospital (Japan)); Iwamiya, T. (Dept. of Radiology, Tottori Univ. Faculty of Medicine, Yonago (Japan) Dept. of Radiology, Matsue City Hospital (Japan)); Tanigawa, N. (Dept. of Radiology, Tottori Univ. Faculty of Medicine, Yonago (Japan) Dept. of Radiology, Matsue City Hospital (Japan)); Shabana, M. (Dept. of Radiology, Tottori Univ. Faculty of Medicine, Yonago (Japan) Dept. of Radiology, Matsue City Hospital (Japan)); Ohta, Y. (Dept. of Radiology, Tottori Univ. Faculty of Medicine, Yonago (Japan) Dept. of Radiology, Matsue City Hospital (Japan))

    1994-03-01

    [sup 123]I-IMP and bone scintigraphy with [sup 99m]Tc-MDP were consecutively performed in patients with vertebral bone metastases from hepatocellular carcinoma and lumbar spondylosis deformans in a 7-day interval or shorter. The intensity of uptake was compared. Eighteen of the 20 metastatic lesions (90%) were classified as increased uptake areas in [sup 123]I-IMP scintigraphy. MDP-scintigraphy disclosed 16 metastatic lesions (80%), 9 as ''hot'' lesions (56%) and 7 as ''cold'' lesions (44%). [sup 123]I-IMP scintigraphy was negative in all 12 lesions of lumbar spondylosis deformans. Compared to MDP-scintigraphy, [sup 123]I-IMP scintigraphy was more sensitive in detecting vertebral bone metastases of hepatocellular carcinoma with smaller rates of false-positive and false-negative findings. (orig./MG).

  7. High-power, high-frequency, annular-beam free-electron maser

    International Nuclear Information System (INIS)

    Fazio, M.V.; Carlsten, B.E.; Earley, L.M.; Fortgang, C.M.; Haynes, W.B.; Haddock, P.C.

    1998-01-01

    The authors have developed a 15--17 GHz free electron maser (FEM) capable of producing high power pulses with a phase stability appropriate for linear collider applications. The electron beam source is a 1 micros, 800 kV, 5 kA, 6-cm-dia annular electron beam machine called BANSHEE. The beam interacts with the TM 02 mode Raman FEM amplifier in a corrugated cylindrical waveguide where the beam runs close to the interaction device walls to reduce the power density in the fields. They studied the phase stability by analyzing the dispersion relation for an axial FEL, in which the rf field was transversely wiggled and the electron trajectories were purely longitudinal. Detailed particle-in-cell simulations demonstrated the transverse wiggling of the rf mode and the axial FEL interaction and explicit calculations of the growing root of the dispersion relation are included to verify the phase stability

  8. Fiber optic probe of free electron evanescent fields in the optical frequency range

    Energy Technology Data Exchange (ETDEWEB)

    So, Jin-Kyu, E-mail: js1m10@orc.soton.ac.uk; MacDonald, Kevin F. [Optoelectronics Research Centre and Centre for Photonic Metamaterials, University of Southampton, Highfield, Southampton SO17 1BJ (United Kingdom); Zheludev, Nikolay I. [Optoelectronics Research Centre and Centre for Photonic Metamaterials, University of Southampton, Highfield, Southampton SO17 1BJ (United Kingdom); Centre for Disruptive Photonic Technologies, Nanyang Technological University, Singapore 637371 (Singapore)

    2014-05-19

    We introduce an optical fiber platform which can be used to interrogate proximity interactions between free-electron evanescent fields and photonic nanostructures at optical frequencies in a manner similar to that in which optical evanescent fields are sampled using nanoscale aperture probes in scanning near-field microscopy. Conically profiled optical fiber tips functionalized with nano-gratings are employed to couple electron evanescent fields to light via the Smith-Purcell effect. We demonstrate the interrogation of medium energy (30–50 keV) electron fields with a lateral resolution of a few micrometers via the generation and detection of visible/UV radiation in the 700–300 nm (free-space) wavelength range.

  9. OPAL Jet Chamber Prototype

    CERN Multimedia

    OPAL was one of the four experiments installed at the LEP particle accelerator from 1989 - 2000. OPAL's central tracking system consists of (in order of increasing radius) a silicon microvertex detector, a vertex detector, a jet chamber, and z-chambers. All the tracking detectors work by observing the ionization of atoms by charged particles passing by: when the atoms are ionized, electrons are knocked out of their atomic orbitals, and are then able to move freely in the detector. These ionization electrons are detected in the dirfferent parts of the tracking system. This piece is a prototype of the jet chambers

  10. Two-Dimensional Free Energy Surfaces for Electron Transfer Reactions in Solution

    Directory of Open Access Journals (Sweden)

    Shigeo Murata

    2008-01-01

    Full Text Available Change in intermolecular distance between electron donor (D and acceptor (A can induce intermolecular electron transfer (ET even in nonpolar solvent, where solvent orientational polarization is absent. This was shown by making simple calculations of the energies of the initial and final states of ET. In the case of polar solvent, the free energies are functions of both D-A distance and solvent orientational polarization. On the basis of 2-dimensional free energy surfaces, the relation of Marcus ET and exciplex formation is discussed. The transient effect in fluorescence quenching was measured for several D-A pairs in a nonpolar solvent. The results were analyzed by assuming a distance dependence of the ET rate that is consistent with the above model.

  11. Diagnosis of Alzheimer's disease and multiple infarct dementia by tomographic imaging of iodine-123 IMP

    International Nuclear Information System (INIS)

    Cohen, M.B.; Graham, L.S.; Lake, R.

    1986-01-01

    Tomographic imaging of the brain was performed using a rotating slant hole collimator and [ 123 I]N-isopropyl p-iodoamphetamine (IMP) in normal subjects (n = 6) and patients with either Alzheimer's disease (n = 5) or multiple infarct dementia (n = 3). Four blinded observers were asked to make a diagnosis from the images. Normal subjects and patients with multiple infarct dementia were correctly identified. Alzheimer's disease was diagnosed in three of the five patients with this disease. One patient with early Alzheimer's disease was classified as normal by two of the four observers. Another patient with Alzheimer's disease had an asymmetric distribution of IMP and was incorrectly diagnosed as multiple infarct dementia by all four observers. Limited angle tomography of the cerebral distribution of 123 I appears to be a useful technique for the evaluation of demented patients

  12. The LLNL/UCLA high gradient inverse free electron laser

    Energy Technology Data Exchange (ETDEWEB)

    Moody, J. T.; Musumeci, P.; Anderson, G.; Anderson, S.; Betts, S.; Fisher, S.; Gibson, D.; Tremaine, A.; Wu, S. [Department of Physics and Astronomy, UCLA, Los Angeles California, 90095 (United States); Lawrence Livermore National Laboratory (United States)

    2012-12-21

    We describe the Inverse Free Electron Accelerator currently under construction at Lawrence Livermore National Lab. Upon completion of this accelerator, high brightness electrons generated in the photoinjector blowout regime and accelerated to 50 MeV by S-band accelerating sections will interact with > 4 TW peak power Ti:Sapphire laser in a highly tapered 50 cm undulator and experience an acceleration gradient of > 200 MeV/m. We present the final design of the accelerator as well as the results of start-to-end simulations investigating preservation of beam quality and tolerances involved with this accelerator.

  13. Gain physics of rf-linac-driven xuv free-electron lasers

    International Nuclear Information System (INIS)

    Goldstein, J.C.; McVey, B.D.; Newnam, B.E.

    1986-01-01

    In an rf-linac-driven xuv free-electron laser oscillator, the gain depends on the details of the shape of the electron beam's phase-space distribution, particularly the distribution of electrons in the transverse (to the direction of propagation) position and velocity coordinates. This strong dependence occurs because the gain in this device is inhomogeneously broadened. Our previous theoretical studies have assumed that the transverse phase space distribution is a product of uncorrelated Gaussian functions. In the present work, we shall present the results of a theoretical study of the gain for non-Gaussian phase-space distributions. Such distributions arise either from a better representation of the electron beam from an rf-linac or from an emittance filter applied to the beam after the linac

  14. [Development Of 25-Year Imp 8 Bow Shock Crossing "List, Ingestion Of This List To Cdaweb, & Enhancement"

    Science.gov (United States)

    Merka, J.; Szabo, A.; Narock, T. W.; King, J. H.; Paularena, K. I.; Richardson, J. D.

    2003-01-01

    The MIT portion of this project was to use the plasma data from IMP 8 to identify bow shock crossings for construction of a bow shock data base. In collaboration with Goddard, we determined which shock parameters would be included in the catalog and developed a set of flags for characterizing the data. IMP 8 data from 1973-2001 were surveyed for bow shock crossings; the crossings apparent in the plasma data were compared to a list of crossing chosen in the magnetometer data by Goddard. Differences were reconciled to produce a single list. The data were then provided to the NSSDC for archiving. All the work ascribed to MIT in the proposal was completed.

  15. Fully local orbital-free calculation of electronic structure using pseudopotentials

    NARCIS (Netherlands)

    Pino, R.; Markvoort, Albert. J.; Santen, van R.A.; Hilbers, P.A.J.

    2003-01-01

    An exactly solvable orbital-free technique is applied to the calculation of the electronic structure of polyatomic systems. The Thomas–Fermi kinetic energy, local exchange, local electrostatic energy functionals, and pseudopotentials are used. Given the potential, the cost of the calculation of the

  16. 6. Seminar of the IIE-ININ-IMP on technological specialties. Topic 3: thermal fluids

    International Nuclear Information System (INIS)

    1992-01-01

    The document includes 10 papers presented at the 6. Seminar of the IIE-ININ-IMP (Mexico) on technological specialties in the field of thermal fluids. (Topic 3). From these, 4 papers were in INIS subject scope and a separate abstract was prepared for each of them

  17. 6. Seminar of the IIE-ININ-IMP on technological specialties. Topic 6: environmental contamination

    International Nuclear Information System (INIS)

    1992-01-01

    The document includes 10 papers presented at the 6. Seminar of the IIE-ININ-IMP on technological specialities in the field of environmental contamination (Topic 6). From these, 6 papers were in INIS subject scope and a separate abstract was prepared for each of these papers

  18. Direct longitudinal laser acceleration of electrons in free space

    Directory of Open Access Journals (Sweden)

    Sergio Carbajo

    2016-02-01

    Full Text Available Compact laser-driven accelerators are pursued heavily worldwide because they make novel methods and tools invented at national laboratories widely accessible in science, health, security, and technology [V. Malka et al., Principles and applications of compact laser-plasma accelerators, Nat. Phys. 4, 447 (2008]. Current leading laser-based accelerator technologies [S. P. D. Mangles et al., Monoenergetic beams of relativistic electrons from intense laser-plasma interactions, Nature (London 431, 535 (2004; T. Toncian et al., Ultrafast laser-driven microlens to focus and energy-select mega-electron volt protons, Science 312, 410 (2006; S. Tokita et al. Single-shot ultrafast electron diffraction with a laser-accelerated sub-MeV electron pulse, Appl. Phys. Lett. 95, 111911 (2009] rely on a medium to assist the light to particle energy transfer. The medium imposes material limitations or may introduce inhomogeneous fields [J. R. Dwyer et al., Femtosecond electron diffraction: “Making the molecular movie,”, Phil. Trans. R. Soc. A 364, 741 (2006]. The advent of few cycle ultraintense radially polarized lasers [S. Carbajo et al., Efficient generation of ultraintense few-cycle radially polarized laser pulses, Opt. Lett. 39, 2487 (2014] has ushered in a novel accelerator concept [L. J. Wong and F. X. Kärtner, Direct acceleration of an electron in infinite vacuum by a pulsed radially polarized laser beam, Opt. Express 18, 25035 (2010; F. Pierre-Louis et al. Direct-field electron acceleration with ultrafast radially polarized laser beams: Scaling laws and optimization, J. Phys. B 43, 025401 (2010; Y. I. Salamin, Electron acceleration from rest in vacuum by an axicon Gaussian laser beam, Phys. Rev. A 73, 043402 (2006; C. Varin and M. Piché, Relativistic attosecond electron pulses from a free-space laser-acceleration scheme, Phys. Rev. E 74, 045602 (2006; A. Sell and F. X. Kärtner, Attosecond electron bunches accelerated and

  19. Formation of presheath and current-free double layer in a two-electron-temperature plasma

    International Nuclear Information System (INIS)

    Sato, Kunihiro; Miyawaki, Fujio

    1992-02-01

    Development of the steady-state potential in a two-temperature-electron plasma in contact with the wall is investigated analytically. It is shown that if the hot- to cold electron temperature ratio is greater than ten, the potential drop in the presheath, which is allowed to have either a small value characterized by the cold electrons or a large value by the hot electrons, discontinuously changes at a critical value for the hot- to total electron density ratio. It is also found that the monotonically decreasing potential structure which consists of the first presheath, a current-free double layer, the second presheath, and the sheath can be steadily formed in a lower range of the hot- to total electron density ratio around the critical value. The current-free double layer is set up due to existence of the two electron species and cold ions generated by ionization so as to connect two presheath potentials at different levels. (author)

  20. Effects of Energy Chirp on Echo-Enabled Harmonic Generation Free-Electron Lasers

    International Nuclear Information System (INIS)

    Huang, Z.

    2009-01-01

    We study effects of energy chirp on echo-enabled harmonic generation (EEHG). Analytical expressions are compared with numerical simulations for both harmonic and bunching factors. We also discuss the EEHG free-electron laser bandwidth increase due to an energy-modulated beam and its pulse length dependence on the electron energy chirp

  1. Aerosol Imaging with a Soft X-ray Free Electron Laser

    International Nuclear Information System (INIS)

    Bogan, Michael J.; Boutet, Sebastien; Chapman, Henry N.; Marchesini, Stefano; Barty, Anton; Benner, W. Henry; Rohner, Urs; Frank, Matthias; Hau-Riege, Stefan P.; Bajt, Sasa; Woods, Bruce; Seibert, M.M.; Iwan, Bianca; Timneanu, Nicusor; Hajdu, Janos; Schulz, Joachim

    2010-01-01

    Lasers have long played a critical role in the advancement of aerosol science. A new regime of ultrafast laser technology has recently be realized, the world's first soft xray free electron laser. The Free electron LASer in Hamburg, FLASH, user facility produces a steady source of 10 femtosecond pulses of 7-32 nm x-rays with 10 12 photons per pulse. The high brightness, short wavelength, and high repetition rate (>500 pulses per second) of this laser offers unique capabilities for aerosol characterization. Here we use FLASH to perform the highest resolution imaging of single PM2.5 aerosol particles in flight to date. We resolve to 35 nm the morphology of fibrous and aggregated spherical carbonaceous nanoparticles that existed for less than two milliseconds in vacuum. Our result opens the possibility for high spatialand time-resolved single particle aerosol dynamics studies, filling a critical technological need in aerosol science.

  2. Evaluation of SPECT with N-isopropyl[I-123]-p-iodoamphetamine (IMP) in epileptic patients

    International Nuclear Information System (INIS)

    Nambu, Toshikazu; Itoh, Kazuo; Sumi, Tetsuo; Furudate, Masayori; Irie, Goro

    1988-01-01

    Brain SPECT scintigrams with N-Isopropyl[I-123]-p-Iodoamphetamine (IMP) were reviewed and compared with the EEG findings in 21 epileptic patients (22 SPECT images) with normal CT. Thirteen of 22 SPECT images showed abnormal low uptake and 7 of them corresponded to the EEG focus. In order to obtain the quantitative analysis, the count ratio of the focus side to the opposite I-123 content in fixed ROI was measured for each case, but no statistically significant correlation for the frequency or the duration of epilepsy was found. EEG is not considered to be favorite standard for localizing epileptic foci, especially in deep cerebral region, and that may be one of the main reason for the incomplete correlation. In the qualitative study, however, the cases with frequent epileptic attack were more likely to show abnormal findings. I-123 IMP SPECT can now be considered as having a significant clinical role for the diagnosis and management of patients with epilepsy. (author)

  3. Regional cerebral blood flow study with 123I-IMP in patients with degenerative dementia

    International Nuclear Information System (INIS)

    Ohnishi, T.; Hoshi, H.; Nagamachi, S.; Jinnouchi, S.; Futami, S.; Watanabe, K.; Mitsuyama, Y.

    1991-01-01

    Regional cerebral blood flow was evaluated by single-photon emission CT (SPECT) with 123I-N-isopropyl-p-iodoamphetamine (123I-IMP) in 11 patients with dementia of the Alzheimer type, three patients with progressive dementia and motor neuron disease, and eight healthy control subjects. Regional blood flow measurements in the bilateral frontal, parietal association, and temporal cortices were lower in the Alzheimer dementia patients than in controls. Flow deficits in the parietal association cortex were demonstrated in all patients with Alzheimer-type dementia; these deficits were correlated with the severity of disease. Lateral hemispheric asymmetry was seen in nine of 11 patients with Alzheimer-type dementia. In all three patients with progressive dementia and motor neuron disease, flow deficits were demonstrated in the bilateral frontal and temporal cortices, but no flow deficits were seen in the parietal association cortex. Brain SPECT with 123I-IMP may be useful in the differential diagnosis and evaluation of the severity of degenerative dementia

  4. Research on heightening of performance of optical system for free electron laser

    International Nuclear Information System (INIS)

    Kumagai, Hiroshi; Kawamura, Yoshiyuki; Toyada, Koichi

    1996-01-01

    Free electron laser will become in future the center of industrial laser technology as a high efficiency, high power output laser. For the development of free electron laser, the development of the elementary technologies such as accelerator, wiggler, optical system and so on must be carried out. For the stable functioning of free electron laser for long hours, the innovative technical development of the optical technology has been strongly desired. In this research, the development of the method of manufacturing a new high performance, multilayer film reflection mirror and the research on compound optical damage by new high energy photon generation process were advanced. The research on the formation of aluminum oxide thin films by using surface reaction, the development of the technology for forming high accuracy, multi-layer thin films and the evaluation of the optical performance of multi-layer films are reported. The constitution of compound optical damage evaluation system, the calculation of the luminance of high energy photons and the experiment on the generation of photons by a carbon dioxide gas laser are described regarding the compound optical damage research. (K.I.)

  5. A GEM-TPC prototype with low-Noise highly integrated front-end electronics for linear collider studies

    CERN Document Server

    Kappler, Steffen; Kaminski, Jochen; Ledermann, Bernhard; Müller, Thomas; Ronan, Michael T; Ropelewski, Leszek; Sauli, Fabio; Settles, Ronald

    2004-01-01

    Connected to the linear collider project, studies on the readout of time projection chambers (TPCs) based on the gas electron multiplier (GEM) are ongoing. Higher granularity and intrinsically suppressed ion feedback are the major advantages of this technology. After a short discussion of these issues, we present the design of a small and very flexible TPC prototype, whose cylindrical drift volume can be equipped with endcaps of different gas detector types. An endcap with multi-GEM readout is currently set up and successfully operated with a low-noise highly integrated front-end electronics. We discuss results of measurements with this system in high intensity particle beams at CERN, where 99.3 plus or minus 0.2% single-pad-row efficiency could be achieved at an effective gain of 2.5 multiplied by 10**3 only, and spatial resolutions down to 63 plus or minus 3 mum could be demonstrated. Finally, these results are extrapolated to the high magnetic field in a linear collider TPC. 5 Refs.

  6. A new prototype of an electronic jet-ventilator and its humidification system

    Science.gov (United States)

    Kraincuk, Paul; Kepka, Anton; Ihra, Gerald; Schabernig, Christa; Aloy, Alexander

    1999-01-01

    Background: Adequate humidification in long-term jet ventilation is a critical aspect in terms of clinical safety. Aim: To assess a prototype of an electronic jet-ventilator and its humidification system. Methods: Forty patients with respiratory insufficiency were randomly allocated to one of four groups. The criterion for inclusion in this study was respiratory insufficiency exhibiting a Murray score above 2. The four groups of patients were ventilated with three different respirators and four different humidification systems. Patients in groups A and B received superimposed high-frequency jet ventilation (SHFJV) by an electronic jet-ventilator either with (group A) or without (group B) an additional humidification system. Patients in group C received high-frequency percussive ventilation (HFPV) by a pneumatic high-frequency respirator, using a hot water humidifier for warming and moistening the inspiration gas. Patients in group D received conventional mechanical ventilation using a standard intensive care unit respirator with a standard humidification system. SHFJV and HFPV were used for a period of 100 h (4days). Results: A significantly low inspiration gas temperature was noted in patients in group B, initially (27.2 ± 2.5°C) and after 2 days (28.0 ± 1.6°C) (P humidification associated with jet ventilation can be fully prevented by using this new jet-ventilator. These data were sustained by nondeteriorating MIS values at the end of the 4-day study period in groups A, C and D. PMID:11056732

  7. Vibrational analysis of a shipboard free electron laser beam path

    OpenAIRE

    Gallant, Bryan M.

    2011-01-01

    This thesis explores the deployment of a free electron laser (FEL) weapon system in a shipboard vibration environment. A concept solid model of a shipboard FEL is developed and used as a basis for a finite element model which is subjected to vibration simulation in MATLAB. Vibration input is obtained from ship shock trials data and wave excited motion data from ship motion simulation software. Emphasis is placed on the motion of electron beam path components of the FEL and the feasibility of ...

  8. Synchrotron radiation and free electron laser activities in Novosibirsk

    International Nuclear Information System (INIS)

    Korchuganov, V.N.; Kulipanov, G.N.; Mezentsev, N.A.; Oreshkov, A.D.; Panchenko, V.E.; Pindyurin, V.F.; Skrinskij, A.N.; Sheromov, M.A.; Vinokurov, N.A.; Zolotarev, K.V.

    1994-01-01

    The results of studies realized in the Siberian synchrotron radiation centre within the frameworks of wide program of synchrotron radiation and free electron laser research are summarized. The technical information on the VEPP-2M, VEPP-3 and VEPP-4M storage rings used as synchrotron radiation sources is given. 10 refs.; 8 figs.; 12 tabs

  9. Characterization of silicon microstrip sensors, front-end electronics, and prototype tracking detectors for the CBM experiment at FAIR

    International Nuclear Information System (INIS)

    Sorokin, Iurii

    2013-01-01

    The Compressed Baryonic Matter (CBM) experiment will explore the phase diagram of strongly interacting matter in the region of high net baryonic densities. The matter at the extreme conditions will be studied in collisions of a heavy ion beam with a fixed heavy element target. The present work is devoted to the development of the main component of the CBM experiment - the Silicon Tracking System (STS). The STS has to enable reconstruction of up to 1000 charged particle tracks per nucleus-nucleus interaction at the rate of up to 10 MHz, provide a momentum resolution Δp/p of 1 %, and withstand the radiation load of up to 10 14 n eq /cm 2 (n eq -neutron equivalent). The STS will be based on double-sided silicon microstrip sensors, that will be arranged in 8 planes in the aperture of the dipole magnet. Selftriggering readout electronics will be located on the periphery of the detecting planes, and connected to the sensors with low mass microcables. In the stage of R and D, as well as in the stages of pre-series and series production, characterization of the sensors, of the front-end electronics, and of the complete detector modules has to be performed. In the present work the required techniques were developed, and the performance of the latest detector prototypes was evaluated. A particular attention is paid to evaluation of the signal amplitude, as it is one of the most important detector characteristics. Techniques for measuring the passive electrical characteristics of the sensors were developed. These include: the coupling and the interstrip capacitances, the interstrip resistance, the bias resistance, the strip leakage current, the bulk capacitance, and the bulk leakage current. The techniques will be applied for the quality assurance of the sensors during the pre-series and the series production. Extensive characterization of the prototype readout chip, n-XYTER, was performed. The register settings were optimized, and the dependence of the amplitude response on

  10. Electron energy and electron trajectories in an inverse free-electron laser accelerator based on a novel electrostatic wiggler

    Science.gov (United States)

    Nikrah, M.; Jafari, S.

    2016-06-01

    We expand here a theory of a high-gradient laser-excited electron accelerator based on an inverse free-electron laser (inverse-FEL), but with innovations in the structure and design. The electrostatic wiggler used in our scheme, namely termed the Paul wiggler, is generated by segmented cylindrical electrodes with applied oscillatory voltages {{V}\\text{osc}}(t) over {{90}\\circ} segments. The inverse-FEL interaction can be described by the equations that govern the electron motion in the combined fields of both the laser pulse and Paul wiggler field. A numerical study of electron energy and electron trajectories has been made using the fourth-order Runge-Kutta method. The results indicate that the electron attains a considerable energy at short distances in this device. It is found that if the electron has got sufficient suitable wiggler amplitude intensities, it can not only gain higher energy in longer distances, but also can retain it even after the passing of the laser pulse. In addition, the results reveal that the electron energy gains different peaks for different initial axial velocities, so that a suitable small initial axial velocity of e-beam produces substantially high energy gain. With regard to the transverse confinement of the electron beam in a Paul wiggler, there is no applied axial guide magnetic field in this device.

  11. Mechanisms for the production of harmonics in free electron lasers

    NARCIS (Netherlands)

    Elgin, J.N.; Penman, C.

    1991-01-01

    Harmonics in the radiation of a free electron laser are useful for extending the range of tuning, may originate in spontaneous or parametric processes, and can take part in stimulated emission or amplification. These mechanisms exhibit interesting analogies with those of nonlinear optics. Apart from

  12. Experimental realization of millimeter-wave amplification by a sheet beam free electron laser

    International Nuclear Information System (INIS)

    Zhang, Z.; Destler, W.W.; Granatstein, V.L.; Antonsen, T.M. Jr.; Levush, B.; Rodgers, J.; Cheng, S.

    1994-01-01

    We report an observation of millimeter-wave (94 GHz) amplification in a sheet beam, short period, planar wiggler, free electron laser amplifier. The observed gain is about 5 dB for a 530 keV, 4 A beam through a 54 cm wiggler. Wave energy absorption was also observed when the beam energy is off-resonance. Experimental results are in good agreement with numerical simulation. This amplifier configuration has potential for producing equally high output power but at relatively low voltage compared with longer period free electron lasers

  13. 8. Seminar of the IMP-IIE-ININ on technological specialties. Topic 9: Analytical Chemistry

    International Nuclear Information System (INIS)

    1996-01-01

    The document includes four papers considered within the INIS subject scope, which were presented at the 8th Seminar of the IMP-IIE-ININ on technological specialities (Section Analytical Chemistry), held on 26 June 1996 in Cuernavaca (Mexico). A separate abstract and indexing were provided for each paper

  14. First-line chemoimmunotherapy in metastatic breast carcinoma: combination of paclitaxel and IMP321 (LAG-3Ig enhances immune responses and antitumor activity

    Directory of Open Access Journals (Sweden)

    Gligorov Joseph

    2010-07-01

    Full Text Available Abstract Background IMP321 is a recombinant soluble LAG-3Ig fusion protein that binds to MHC class II with high avidity and mediates APC and then antigen-experienced memory CD8+ T cell activation. We report clinical and biological results of a phase I/II in patients with metastatic breast carcinoma (MBC receiving first-line paclitaxel weekly, 3 weeks out of 4. Methods MBC patients were administered one dose of IMP321 s.c. every two weeks for a total of 24 weeks (12 injections. The repeated single doses were administered the day after chemotherapy at D2 and D16 of the 28-day cycles of paclitaxel (80 mg/m2 at D1, D8 and D15, for 6 cycles. Blood samples were taken 13 days after the sixth and the twelfth IMP321 injections to determine sustained APC, NK and memory CD8 T cell responses. Results Thirty MBC patients received IMP321 in three cohorts (doses: 0.25, 1.25 and 6.25 mg. IMP321 induced both a sustained increase in the number and activation of APC (monocytes and dendritic cells and an increase in the percentage of NK and long-lived cytotoxic effector-memory CD8 T cells. Clinical benefit was observed for 90% of patients with only 3 progressors at 6 months. Also, the objective tumor response rate of 50% compared favorably to the 25% rate reported in the historical control group. Conclusions The absence of toxicity and the demonstration of activity strongly support the future development of this agent for clinical use in combined first-line regimens. Trial registration ClinicalTrials.gov NCT00349934

  15. Studies on GEM modules for a large prototype TPC for the ILC

    International Nuclear Information System (INIS)

    Tsionou, Dimitra

    2016-12-01

    The International Linear Collider (ILC) is a future electron-positron collider with centre of mass energy of 500-1000 GeV. The International Large Detector (ILD) is one of two detector concepts at the ILC. Its high precision tracking system consists of Silicon sub-detectors and a Time Projection Chamber (TPC) equipped with micro-pattern gas detectors (MPGDs). Within the framework of the LCTPC collaboration, a Large Prototype (LP) TPC has been built as a demonstrator. This prototype has been equipped with Gas Electron Multiplier (GEM) modules and studied with electron beams of energies 1-6 GeV at the DESY test beam facility. The performance of the prototype detector and the extrapolation to the ILD TPC is presented here. In addition, ongoing optimisation studies and R and D; activities in order to prepare the next GEM module iteration are discussed.

  16. Inter-dependence of the electron beam excitations with the free electron laser stability on the super-ACO storage ring

    CERN Document Server

    Couprie, Marie Emmanuelle; Nutarelli, D; Renault, E; Billardon, M

    1999-01-01

    Storage ring free electron lasers have a complex dynamics as compared to the LINAC driven FEL sources since both the laser and the recirculating electron beam behaviours are involved. Electron beam perturbations can strongly affect the FEL operation (start-up, stability) whereas the FEL can stabilize beam instabilities. Experimental analysis together with simulations are reported here. Improvements of the Super-ACO FEL for users is discussed, and consequences are given in terms of electron beam tolerances for a source development for users.

  17. Customization of gaming technology and prototyping of rehabilitation applications

    DEFF Research Database (Denmark)

    Herbelin, Bruno; Ciger, Jan; Lewis Brooks, Anthony

    2008-01-01

    The field of rehabilitation has recently seen various experimentations with games using interfaces that require physical activity. In order to establish the basis for developments and experimentations with those interactive systems, we propose a rapid prototyping approach using various commercial...... and to elaborate on the use of such systems. In other words, the availability of a simple prototyping platform with free games and new interfaces already opens the discussion on the design of original rehabilitation applications....... devices and open source software. To demonstrate this idea, we first show how a simple free game can be adapted to specific needs − for training or use by disabled people − by using different sensors and control modes. Similarly, we show that an open on-line virtual world such as Second Life, although...

  18. Integrated Plan-Procedures-Telemetry Ops Concept and Prototype

    Data.gov (United States)

    National Aeronautics and Space Administration — The project scope includes developing the ops concept and prototype for a near-seamless interface between mission plans, electronic procedures and live telemetry...

  19. Nonlinear effects and conversion efficiency of free electron laser in compton regime

    International Nuclear Information System (INIS)

    Taguchi, Toshihiro; Mima, Kunioki; Mochizuki, Takayasu

    1980-01-01

    Nonlinear evolutions of free electron laser are analyzed by using quasi-linear theory. By the analysis, the energy conversion rates and the spectral width of the emitted radiations are calculated self-consistently. Moreover, it is found that the energy conversion rate is remarkably improved, when a RF field is applied to reaccelerate electron beam. (author)

  20. CMOS technology: a critical enabler for free-form electronics-based killer applications

    Science.gov (United States)

    Hussain, Muhammad M.; Hussain, Aftab M.; Hanna, Amir

    2016-05-01

    Complementary metal oxide semiconductor (CMOS) technology offers batch manufacturability by ultra-large-scaleintegration (ULSI) of high performance electronics with a performance/cost advantage and profound reliability. However, as of today their focus has been on rigid and bulky thin film based materials. Their applications have been limited to computation, communication, display and vehicular electronics. With the upcoming surge of Internet of Everything, we have critical opportunity to expand the world of electronics by bridging between CMOS technology and free form electronics which can be used as wearable, implantable and embedded form. The asymmetry of shape and softness of surface (skins) in natural living objects including human, other species, plants make them incompatible with the presently available uniformly shaped and rigidly structured today's CMOS electronics. But if we can break this barrier then we can use the physically free form electronics for applications like plant monitoring for expansion of agricultural productivity and quality, we can find monitoring and treatment focused consumer healthcare electronics - and many more creative applications. In our view, the fundamental challenge is to engage the mass users to materialize their creative ideas. Present form of electronics are too complex to understand, to work with and to use. By deploying game changing additive manufacturing, low-cost raw materials, transfer printing along with CMOS technology, we can potentially stick high quality CMOS electronics on any existing objects and embed such electronics into any future objects that will be made. The end goal is to make them smart to augment the quality of our life. We use a particular example on implantable electronics (brain machine interface) and its integration strategy enabled by CMOS device design and technology run path.

  1. First experimental results of the BNL inverse free electron laser accelerator

    International Nuclear Information System (INIS)

    Steenbergen, A. van; Gallardo, J.; Babzien, M.; Skaritka, J.; Wang, X.J.; Sandweiss, J.; Fang, J.M.; Qiu, X.

    1996-10-01

    A 40 MeV electron beam, using the inverse3e free-electron laser interaction, has been accelerated by ΔE/E = 2.5% over a distance of 0.47 m. The electrons interact with a 1--2 GW CO 2 laser beam bounded by a 2.8 mm ID sapphire circular waveguide in the presence of a tapered wiggler with Bmax ∼ 1 T and a period 2.89 cm ≤ λ w ≤ 3.14 cm. The experimental results of ΔE/E as a function of electron energy E, peak magnetic field Bw and laser power W 1 compare well with analytical and 1-D numerical simulations and permit scaling to higher laser power and electron energy

  2. Lipid-protein nanodiscs for cell-free production of integral membrane proteins in a soluble and folded state: comparison with detergent micelles, bicelles and liposomes.

    Science.gov (United States)

    Lyukmanova, E N; Shenkarev, Z O; Khabibullina, N F; Kopeina, G S; Shulepko, M A; Paramonov, A S; Mineev, K S; Tikhonov, R V; Shingarova, L N; Petrovskaya, L E; Dolgikh, D A; Arseniev, A S; Kirpichnikov, M P

    2012-03-01

    Production of integral membrane proteins (IMPs) in a folded state is a key prerequisite for their functional and structural studies. In cell-free (CF) expression systems membrane mimicking components could be added to the reaction mixture that promotes IMP production in a soluble form. Here lipid-protein nanodiscs (LPNs) of different lipid compositions (DMPC, DMPG, POPC, POPC/DOPG) have been compared with classical membrane mimicking media such as detergent micelles, lipid/detergent bicelles and liposomes by their ability to support CF synthesis of IMPs in a folded and soluble state. Three model membrane proteins of different topology were used: homodimeric transmembrane (TM) domain of human receptor tyrosine kinase ErbB3 (TM-ErbB3, 1TM); voltage-sensing domain of K(+) channel KvAP (VSD, 4TM); and bacteriorhodopsin from Exiguobacterium sibiricum (ESR, 7TM). Structural and/or functional properties of the synthesized proteins were analyzed. LPNs significantly enhanced synthesis of the IMPs in a soluble form regardless of the lipid composition. A partial disintegration of LPNs composed of unsaturated lipids was observed upon co-translational IMP incorporation. Contrary to detergents the nanodiscs resulted in the synthesis of ~80% active ESR and promoted correct folding of the TM-ErbB3. None of the tested membrane mimetics supported CF synthesis of correctly folded VSD, and the protocol of the domain refolding was developed. The use of LPNs appears to be the most promising approach to CF production of IMPs in a folded state. NMR analysis of (15)N-Ile-TM-ErbB3 co-translationally incorporated into LPNs shows the great prospects of this membrane mimetics for structural studies of IMPs produced by CF systems. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Material dependence of electron inelastic mean free paths at low energies

    International Nuclear Information System (INIS)

    Tanuma, S.; Powell, C.J.; Penn, D.R.

    1990-01-01

    We present and discuss electron inelastic mean free path (IMFP) data for aluminum and gold in the 50--200 eV range. These elements serve as examples of IMFP calculations that have been made for 50--2000 eV electrons in 31 materials (27 elements and 4 compounds). Substantial differences are found in the shapes of the IMFP versus energy curves for Al and Au and these can be understood in terms of the different inelastic scattering mechanisms in the two metals. The minimum IMFP value occurs at 40 eV in aluminum and at 120 eV in gold, a result which is consistent with the trends expected from free-electron IMFP calculations. This result differs, however, from that expected from the Seah and Dench attenuation length formula which shows essentially no material dependence at low energies. We have extended a general formula derived earlier to describe the calculated IMFPs over the 200--2000 eV energy range to give the IMFP dependences on material and energy from 50 to 2000 eV

  4. Electron attenuation in free, neutral ethane clusters.

    Science.gov (United States)

    Winkler, M; Myrseth, V; Harnes, J; Børve, K J

    2014-10-28

    The electron effective attenuation length (EAL) in free, neutral ethane clusters has been determined at 40 eV kinetic energy by combining carbon 1s x-ray photoelectron spectroscopy and theoretical lineshape modeling. More specifically, theory is employed to form model spectra on a grid in cluster size (N) and EAL (λ), allowing N and λ to be determined by optimizing the goodness-of-fit χ(2)(N, λ) between model and observed spectra. Experimentally, the clusters were produced in an adiabatic-expansion setup using helium as the driving gas, spanning a range of 100-600 molecules in mean cluster size. The effective attenuation length was determined to be 8.4 ± 1.9 Å, in good agreement with an independent estimate of 10 Å formed on the basis of molecular electron-scattering data and Monte Carlo simulations. The aggregation state of the clusters as well as the cluster temperature and its importance to the derived EAL value are discussed in some depth.

  5. Investigation of metal coatings for the free electron laser

    International Nuclear Information System (INIS)

    Scott, M.L.; Arendt, P.N.; Springer, R.W.; Cordi, R.C.; McCreary, W.J.

    1985-01-01

    We are investigating the deposition and characteristics of metal coatings for use in environments such as the Free Electron Laser where the radiation resistance of metal coatings could prove to be of great benefit. We have concentrated our initial efforts on silver laminate coatings due to the high reflectance of silver at 1 micron wavelength. Our initial laminate coatings have utilized thin layers of titanium oxide to break up the columnar structure of the silver during electron-beam deposition on fused silica substrates. Our initial results on equal coating thickness samples indicate an improvement in damage threshold that ranges from 1.07 to 1.71 at 351 nm

  6. An Inverse Free-Electron-Laser accelerator

    International Nuclear Information System (INIS)

    Fisher, A.S.; Gallardo, J.C.; van Steenbergen, A.; Ulc, S.; Woodle, M.; Sandweiss, J.; Fang, Jyan-Min

    1993-01-01

    Recent work at BNL on electron acceleration using the Inverse Free-Electron Laser (IFEL) has considered a low-energy, high-gradient, multi-stage linear accelerator. Experiments are planned at BNL's Accelerator Test Facility using its 50-MeV linac and 100-GW CO 2 laser. We have built and tested a fast-excitation wiggler magnet with constant field, tapered period, and overall length of 47 cm. Vanadium-Permendur ferromagnetic laminations are stacked in alternation with copper, eddy-current-induced, field reflectors to achieve a 1.4-T peak field with a 4-mm gap and a typical period of 3 cm. The laser beam will pass through the wiggler in a low-loss, dielectric-coated stainless-steel, rectangular waveguide. The attenuation and transverse mode has been measured in waveguide sections of various lengths, with and without the dielectric. Results of 1-D and 3-D IFEL simulations, including wiggler errors, will be presented for several cases: the initial, single-module experiment with ΔE = 39 MeV, a four-module design giving ΔE = 100 MeV in a total length of 2 m, and an eight-module IFEL with ΔE = 210 MeV

  7. [sup 123]I-IMP SPECT studies in schizophrenia and atypical psychosis

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Takuji; Suga, Hidemichi (Aichi Medical University, Nagakute (Japan))

    1993-05-01

    According to the classification of Mitsuda, 23 patients with endogenous psychosis aged 40 years or younger, presenting with hallucination and delusion, were classified as having schizophrenia (n=12) or atypical psychosis (n=11). These patients were studied by single photon emission computed tomography (SPECT) with N-isopropyl-p-I-123-iodoamphetamine (I-123 IMP). Sixteen healthy persons served as controls. Early and delayed SPECT images were obtained 30 min and 4 hr, respectively, after intravenous injection of I-123 IMP. The group of schizophrenic patients had markedly decreased uptake of I-123 in the basal ganglia, as well as the right temporal and left occipital areas on both early and delayed images. In the group of atypical psychosis patients, however, decreased uptake of I-123 was noted in both the right basal ganglia and left occipital area on early images, but none of such findings were seen on delayed images. Regarding the uptake ratio in the frontal area on both early and delayed images, there were significant differences between the two groups. These findings have important implications for the different etiology of both disease types: not only functional disturbance in the frontal area but also irreversible changes may be involved in the occurrence of schizophrenia, and functional disturbance particularly in the right basal ganglia may be involved in the occurrence of atypical psychosis. (N.K.).

  8. Joseph Roth, tradutor do Império perdido

    Directory of Open Access Journals (Sweden)

    Luis S. Krausz

    2015-06-01

    Full Text Available Este artigo discute um folhetim jornalístico do escritor austríaco Joseph Roth que trata de uma miniatura do Templo de Salomão, encontrada por ele num café da Hirtenstrasse berlinense, no coração do que foi, na década de 1920, o bairro habitado pelos judeus do Leste da Europa na capital alemã. A nostalgia, sob cujo signo foi criada tal miniatura, torna-se uma metáfora da nostalgia pelo império Austro-Húngaro, chave para a compreensão da obra romanesca deste escritor. Ao mesmo tempo, esta nostalgia rothiana é contextualizada no âmbito das crenças místicas e messiânicas do judaísmo tradicional.

  9. Overexpression of the OsIMP Gene Increases the Accumulation of Inositol and Confers Enhanced Cold Tolerance in Tobacco through Modulation of the Antioxidant Enzymes' Activities.

    Science.gov (United States)

    Zhang, Rong-Xiang; Qin, Li-Jun; Zhao, De-Gang

    2017-07-20

    Inositol is a cyclic polyol that is involved in various physiological processes, including signal transduction and stress adaptation in plants. l- myo -inositol monophosphatase (IMPase) is one of the metal-dependent phosphatase family members and catalyzes the last reaction step of biosynthesis of inositol. Although increased IMPase activity induced by abiotic stress has been reported in chickpea plants, the role and regulation of the IMP gene in rice ( Oryza sativa L.) remains poorly understood. In the present work, we obtained a full-length cDNA sequence coding IMPase in the cold tolerant rice landraces in Gaogonggui, which is named as OsIMP . Multiple alignment results have displayed that this sequence has characteristic signature motifs and conserved enzyme active sites of the phosphatase super family. Phylogenetic analysis showed that IMPase is most closely related to that of the wild rice Oryza brachyantha , while transcript analysis revealed that the expression of the OsIMP is significantly induced by cold stress and exogenous abscisic acid (ABA) treatment. Meanwhile, we cloned the 5' flanking promoter sequence of the OsIMP gene and identified several important cis -acting elements, such as LTR (low-temperature responsiveness), TCA-element (salicylic acid responsiveness), ABRE-element (abscisic acid responsiveness), GARE-motif (gibberellin responsive), MBS (MYB Binding Site) and other cis -acting elements related to defense and stress responsiveness. To further investigate the potential function of the OsIMP gene, we generated transgenic tobacco plants overexpressing the OsIMP gene and the cold tolerance test indicated that these transgenic tobacco plants exhibit improved cold tolerance. Furthermore, transgenic tobacco plants have a lower level of hydrogen peroxide (H₂O₂) and malondialdehyde (MDA), and a higher content of total chlorophyll as well as increased antioxidant enzyme activities of superoxide dismutase (SOD), catalase (CAT) and peroxidase (POD

  10. Effect of flavoring chemicals on free radical formation in electronic cigarette aerosols.

    Science.gov (United States)

    Bitzer, Zachary T; Goel, Reema; Reilly, Samantha M; Elias, Ryan J; Silakov, Alexey; Foulds, Jonathan; Muscat, Joshua; Richie, John P

    2018-05-20

    Flavoring chemicals, or flavorants, have been used in electronic cigarettes (e-cigarettes) since their inception; however, little is known about their toxicological effects. Free radicals present in e-cigarette aerosols have been shown to induce oxidative stress resulting in damage to proliferation, survival, and inflammation pathways in the cell. Aerosols generated from e-liquid solvents alone contain high levels of free radicals but few studies have looked at how these toxins are modulated by flavorants. We investigated the effects of different flavorants on free radical production in e-cigarette aerosols. Free radicals generated from 49 commercially available e-liquid flavors were captured and analyzed using electron paramagnetic resonance (EPR). The flavorant composition of each e-liquid was analyzed by gas chromatography mass spectroscopy (GCMS). Radical production was correlated with flavorant abundance. Ten compounds were identified and analyzed for their impact on free radical generation. Nearly half of the flavors modulated free radical generation. Flavorants with strong correlations included β-damascone, δ-tetradecalactone, γ-decalactone, citral, dipentene, ethyl maltol, ethyl vanillin, ethyl vanillin PG acetal, linalool, and piperonal. Dipentene, ethyl maltol, citral, linalool, and piperonal promoted radical formation in a concentration-dependent manner. Ethyl vanillin inhibited the radical formation in a concentration dependent manner. Free radical production was closely linked with the capacity to oxidize biologically-relevant lipids. Our results suggest that flavoring agents play an important role in either enhancing or inhibiting the production of free radicals in flavored e-cigarette aerosols. This information is important for developing regulatory strategies aimed at reducing potential harm from e-cigarettes. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Compact free-electron laser at the Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Chan, K.C.D.; Meier, K.L.; Nguyen, D.; Sheffield, R.L.; Wang, Tai-Sen F.; Warren, R.W.; Wilson, W.L.; Young, L.M.

    1991-01-01

    The design and construction of second-generation free-electron laser (FEL) system at Los Alamos will be described. comprising state-of-the art components, this FEL system will be sufficiently compact, robust and user-friendly for application in industry, medicine, and research. 11 refs., 11 figs., 2 tabs

  12. Practical electronics for inventors

    CERN Document Server

    Scherz, Paul

    2013-01-01

    Spark your creativity and gain the electronics skills required to transform your innovative ideas into functioning gadgets. This hands-on, updated guide outlines electrical principles and provides thorough, easy-to-follow instructions, schematics, and illustrations. Findout how to select components, safely assemble circuits, perform error tests, and build plug-and-play prototypes. Practical Electronics for Inventors, Third Edition, features all-new chapters on sensors, microcontrollers, modular electronics, and the latest software tools. Coverage includes: Resistors, capacitors, inductors, and transformers Diodes, transistors, and integrated circuits Optoelectronics, solar cells, and phototransistors Sensors, GPS modules, and touch screens Op amps, regulators, and power supplies Digital electronics, LCD displays, and logic gates Microcontrollers and prototyping platforms, including Arduino DC motors, RC servos, and stepper motors Microphones, audio amps, and speakers Modular electronics and prototyping.

  13. The stability of free-electron lasers against filamentation

    International Nuclear Information System (INIS)

    Barnard, J.J.; Scharlemann, E.T.; Yu, S.S.

    1987-01-01

    In inertial confinement fusion (ICF) experiments, the high electromagnetic fields propagating through a relatively dense plasma can result in a transverse instability, causing the matter and light to form filaments oriented parallel to the light beam. We examine whether a similar instability exists in the electron beam of a free-electron laser, where such an instability could interfere with the transfer of beam kinetic energy into optical wave energy. We heuristically examine the instability in a relativistic beam through which an intense laser beam is propagating. We ignore the FEL effects. We estimate how the altered index of refraction in an FEL affects the dispersion relation. Finally, we estimate the effect that the instability could have on the phase coherence of a particle as it transits an FEL. 10 refs., 2 tabs

  14. Studies of a full-scale mechanical prototype line for the ANTARES neutrino telescope and tests of a prototype instrument for deep-sea acoustic measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ageron, M. [CPPM-Centre de Physique des Particules de Marseille, CNRS/IN2P3 et Universite de la Mediterranee, 163 Avenue de Luminy, Case 902, 13288 Marseille Cedex 9 (France); Aguilar, J.A. [IFIC-Instituto de Fisica Corpuscular, Edificios Investigacion de Paterna, CSIC-Universitat de Valencia, Apdo. de Correos 22085, 46071 Valencia (Spain); Albert, A. [GRPHE-Groupe de Recherche en Physique des Hautes Energies, Universite de Haute Alsace, 61 Rue Albert Camus, 68093 Mulhouse Cedex (France); Ameli, F. [Dipartimento di Fisica dell' Universita ' La Sapienza' e Sezione INFN, P.le Aldo Moro 2, 00185 Roma (Italy); Anghinolfi, M. [Dipartimento di Fisica dell' Universita e Sezione INFN, Via Dodecaneso 33, 16146 Genova (Italy); Anton, G. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Physikalisches Institut, Erwin-Rommel-Str. 1, D-91058 Erlangen (Germany); Anvar, S.; Ardellier-Desages, F. [DSM/DAPNIA-Direction des Sciences de la Matiere, Laboratoire de Recherche sur les lois Fondamentales de l' Univers, CEA Saclay, 91191 Gif-sur-Yvette Cedex (France); Aslanides, E.; Aubert, J.-J. [CPPM-Centre de Physique des Particules de Marseille, CNRS/IN2P3 et Universite de la Mediterranee, 163 Avenue de Luminy, Case 902, 13288 Marseille Cedex 9 (France); Auer, R. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Physikalisches Institut, Erwin-Rommel-Str. 1, D-91058 Erlangen (Germany); Barbarito, E. [Dipartimento Interateneo di Fisica e Sezione INFN, Via E. Orabona 4, 70126 Bari (Italy); Basa, S. [LAM-Laboratoire d' Astrophysique de Marseille, CNRS/INSU et Universite de Provence, Traverse du Siphon-Les Trois Lucs, BP 8, 13012 Marseille Cedex 12 (France); Battaglieri, M. [Dipartimento di Fisica dell' Universita e Sezione INFN, Via Dodecaneso 33, 16146 Genova (Italy); Bazzotti, M.; Becherini, Y. [Dipartimento di Fisica dell' Universita e Sezione INFN, Viale Berti Pichat 6/2, 40127 Bologna (Italy)] (and others)

    2007-11-01

    A full-scale mechanical prototype line was deployed to a depth of 2500 m to test the leak tightness of the electronics containers and the pressure-resistant properties of an electromechanical cable under evaluation for use in the ANTARES deep-sea neutrino telescope. During a month-long immersion study, line parameter data were taken using miniature autonomous data loggers and shore-based optical time domain reflectometry. Details of the mechanical prototype line, the electromechanical cable and data acquisition are presented. Data taken during the immersion study revealed deficiencies in the pressure resistance of the electromechanical cable terminations at the entry points to the electronics containers. The improvements to the termination, which have been integrated into subsequent detection lines, are discussed. The line also allowed deep-sea acoustic measurements with a prototype hydrophone system. The technical setup of this system is described, and the first results of the data analysis are presented.

  15. Studies of a full-scale mechanical prototype line for the ANTARES neutrino telescope and tests of a prototype instrument for deep-sea acoustic measurements

    International Nuclear Information System (INIS)

    Ageron, M.; Aguilar, J.A.; Albert, A.; Ameli, F.; Anghinolfi, M.; Anton, G.; Anvar, S.; Ardellier-Desages, F.; Aslanides, E.; Aubert, J.-J.; Auer, R.; Barbarito, E.; Basa, S.; Battaglieri, M.; Bazzotti, M.; Becherini, Y.

    2007-01-01

    A full-scale mechanical prototype line was deployed to a depth of 2500 m to test the leak tightness of the electronics containers and the pressure-resistant properties of an electromechanical cable under evaluation for use in the ANTARES deep-sea neutrino telescope. During a month-long immersion study, line parameter data were taken using miniature autonomous data loggers and shore-based optical time domain reflectometry. Details of the mechanical prototype line, the electromechanical cable and data acquisition are presented. Data taken during the immersion study revealed deficiencies in the pressure resistance of the electromechanical cable terminations at the entry points to the electronics containers. The improvements to the termination, which have been integrated into subsequent detection lines, are discussed. The line also allowed deep-sea acoustic measurements with a prototype hydrophone system. The technical setup of this system is described, and the first results of the data analysis are presented

  16. Dependence of electron inelastic mean free paths on electron energy and materials at low energy region, 1

    International Nuclear Information System (INIS)

    Tanuma, Shigeo; Powell, C.J.; Penn, D.R.

    1990-01-01

    We have proposed a general formula of electron inelastic mean free path (IMFP) to describe the calculated IMFPs over the 50-2000 eV energy range based on the Inokuti's modified Bethe formula for the inelastic scattering cross section. The IMFPs for 50-2000 eV electrons in 27 elements were calculated using Penn's algorithm. The IMFP dependence on electron energy in the range 50-200 eV varies considerably from material to material. These variations are associated with substantial differences in the electron energy-loss functions amongst the material. We also found that the modified Bethe formula by Inokuti could be fitted to the calculated IMFPs in the range 50-2000 eV within 3% relative error. (author)

  17. 3-D numerical analysis of a high-gain free-electron laser

    International Nuclear Information System (INIS)

    Gallardo, J.C.

    1988-01-01

    We present a novel approach to the 3-dimensional high-gain free- electron laser amplifier problem. The method allows us to write the laser field as an integral equation which can be efficiently and accurately evaluated on a small computer. The model is general enough to allow the inclusion of various initial electron beam distributions to study the gain reduction mechanism and its dependence on the physical parameters. 16 refs., 8 figs., 1 tab

  18. Present status of storage ring free electron laser experiment at ETL

    International Nuclear Information System (INIS)

    Yamazaki, T.; Nakamura, T.; Tomimasu, T.; Sugiyama, S.; Noguchi, T.

    1988-01-01

    Outline is described of the present status of the ETL storage-ring free electron laser project. The structure and the performance of the ETL-type transverse optical klystron are given. A modification of the dispersive section has decreased the degradation of the shape of the spontaneous-emission spectrum due to energy spread of the electron beam. Relevant parameters of the stored beam are presented. Measurement of the optical-cavity loss is under way. (author)

  19. Ultrafast magnetodynamics with free-electron lasers

    Science.gov (United States)

    Malvestuto, Marco; Ciprian, Roberta; Caretta, Antonio; Casarin, Barbara; Parmigiani, Fulvio

    2018-02-01

    The study of ultrafast magnetodynamics has entered a new era thanks to the groundbreaking technological advances in free-electron laser (FEL) light sources. The advent of these light sources has made possible unprecedented experimental schemes for time-resolved x-ray magneto-optic spectroscopies, which are now paving the road for exploring the ultimate limits of out-of-equilibrium magnetic phenomena. In particular, these studies will provide insights into elementary mechanisms governing spin and orbital dynamics, therefore contributing to the development of ultrafast devices for relevant magnetic technologies. This topical review focuses on recent advancement in the study of non-equilibrium magnetic phenomena from the perspective of time-resolved extreme ultra violet (EUV) and soft x-ray spectroscopies at FELs with highlights of some important experimental results.

  20. Architectures of prototypes and architectural prototyping

    DEFF Research Database (Denmark)

    Hansen, Klaus Marius; Christensen, Michael; Sandvad, Elmer

    1998-01-01

    together as a team, but developed a prototype that more than fulfilled the expectations of the shipping company. The prototype should: - complete the first major phase within 10 weeks, - be highly vertical illustrating future work practice, - continuously live up to new requirements from prototyping......This paper reports from experience obtained through development of a prototype of a global customer service system in a project involving a large shipping company and a university research group. The research group had no previous knowledge of the complex business of shipping and had never worked...... sessions with users, - evolve over a long period of time to contain more functionality - allow for 6-7 developers working intensively in parallel. Explicit focus on the software architecture and letting the architecture evolve with the prototype played a major role in resolving these conflicting...

  1. Collaborative Prototyping

    DEFF Research Database (Denmark)

    Bogers, Marcel; Horst, Willem

    2014-01-01

    of the prototyping process, the actual prototype was used as a tool for communication or development, thus serving as a platform for the cross-fertilization of knowledge. In this way, collaborative prototyping leads to a better balance between functionality and usability; it translates usability problems into design......This paper presents an inductive study that shows how collaborative prototyping across functional, hierarchical, and organizational boundaries can improve the overall prototyping process. Our combined action research and case study approach provides new insights into how collaborative prototyping...... can provide a platform for prototype-driven problem solving in early new product development (NPD). Our findings have important implications for how to facilitate multistakeholder collaboration in prototyping and problem solving, and more generally for how to organize collaborative and open innovation...

  2. Development of a high power millimeter wave free-electron laser amplifier

    International Nuclear Information System (INIS)

    Bidwell, S.W.; Zhang, Z.X.; Antonsen, T.M. Jr.; Destler, W.W.; Granatstein, V.L.; Levush, B.; Rodgers, J.; Freund, H.P.

    1992-01-01

    Progress on the development of a high-average-power millimeter wave free-electron laser amplifier is reported. Successful sheet electron beam propagation has been observed through a 54 cm long wiggler magnet. One hundred percent transport efficiency is reported with a 15 A, 0.1 cm x 2.0 cm, sheet electron beam through B w = 5.1 kG, λ w = 0.96 cm, planar electromagnet wiggler. Preliminary success with a novel, yet simple, method of side focusing using offset poles is reported. Status of development on a 94 GHz, 180 kW, pulsed amplifier is discussed with results from numerical simulation

  3. Properties of the transfer matrices of deflecting magnet systems for free electron laser

    International Nuclear Information System (INIS)

    Takao, Masaru

    1993-01-01

    The oscillation of the free electron laser (FEL) requires the high current and low emittance electron beam. The beam transport system should be achromatic and isochronous to preserve the brightness and the emittance of the electron beam. In this paper we clarify the algebraic properties of the transfer matrices of the magnetic deflection system, which is a key component in the beam transport line. (author)

  4. Energetic electron anisotropies in the magnetotail - Identification of open and closed field lines

    Science.gov (United States)

    Baker, D. N.; Stone, E. C.

    1976-01-01

    Unidirectional anisotropies in the energetic electron fluxes (E greater than or equal to about 200 keV) have been observed in the earth's magnetotail with the Caltech Electron/Isotope Spectrometer on IMP-8. The anisotropies occur during periods of enhanced fluxes and provide essential information on the topology (open or closed) of the magnetotail field lines which are associated with recently identified acceleration regions.

  5. Longitudinal space charge assisted echo seeding of a free-electron laser with laser-spoiler noise suppression

    Directory of Open Access Journals (Sweden)

    Kirsten Hacker

    2014-09-01

    Full Text Available Seed lasers are employed to improve the temporal coherence of free-electron laser (FEL light. However, when these seed pulses are short relative to the particle bunch, the noisy, temporally incoherent radiation from the unseeded electrons can overwhelm the coherent, seeded radiation. In this paper, a technique to seed a particle bunch with an external laser is presented in which a new mechanism to improve the contrast between coherent and incoherent free electron laser radiation is employed together with a novel, simplified echo-seeding method. The concept relies on a combination of longitudinal space charge wakes and an echo-seeding technique to make a short, coherent pulse of FEL light together with noise background suppression. Several different simulation codes are used to illustrate the concept with conditions at the soft x-ray free-electron laser in Hamburg, FLASH.

  6. CMOS technology: a critical enabler for free-form electronics-based killer applications

    KAUST Repository

    Hussain, Muhammad Mustafa

    2016-05-17

    Complementary metal oxide semiconductor (CMOS) technology offers batch manufacturability by ultra-large-scaleintegration (ULSI) of high performance electronics with a performance/cost advantage and profound reliability. However, as of today their focus has been on rigid and bulky thin film based materials. Their applications have been limited to computation, communication, display and vehicular electronics. With the upcoming surge of Internet of Everything, we have critical opportunity to expand the world of electronics by bridging between CMOS technology and free form electronics which can be used as wearable, implantable and embedded form. The asymmetry of shape and softness of surface (skins) in natural living objects including human, other species, plants make them incompatible with the presently available uniformly shaped and rigidly structured today’s CMOS electronics. But if we can break this barrier then we can use the physically free form electronics for applications like plant monitoring for expansion of agricultural productivity and quality, we can find monitoring and treatment focused consumer healthcare electronics – and many more creative applications. In our view, the fundamental challenge is to engage the mass users to materialize their creative ideas. Present form of electronics are too complex to understand, to work with and to use. By deploying game changing additive manufacturing, low-cost raw materials, transfer printing along with CMOS technology, we can potentially stick high quality CMOS electronics on any existing objects and embed such electronics into any future objects that will be made. The end goal is to make them smart to augment the quality of our life. We use a particular example on implantable electronics (brain machine interface) and its integration strategy enabled by CMOS device design and technology run path. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is

  7. Towards Gotthard-II: development of a silicon microstrip detector for the European X-ray Free-Electron Laser

    Science.gov (United States)

    Zhang, J.; Andrä, M.; Barten, R.; Bergamaschi, A.; Brückner, M.; Dinapoli, R.; Fröjdh, E.; Greiffenberg, D.; Lopez-Cuenca, C.; Mezza, D.; Mozzanica, A.; Ramilli, M.; Redford, S.; Ruat, M.; Ruder, C.; Schmitt, B.; Shi, X.; Thattil, D.; Tinti, G.; Turcato, M.; Vetter, S.

    2018-01-01

    Gotthard-II is a 1-D microstrip detector specifically developed for the European X-ray Free-Electron Laser. It will not only be used in energy dispersive experiments but also as a beam diagnostic tool with additional logic to generate veto signals for the other 2-D detectors. Gotthard-II makes use of a silicon microstrip sensor with a pitch of either 50 μm or 25 μm and with 1280 or 2560 channels wire-bonded to adaptive gain switching readout chips. Built-in analog-to-digital converters and digital memories will be implemented in the readout chip for a continuous conversion and storage of frames for all bunches in the bunch train. The performance of analogue front-end prototypes of Gotthard has been investigated in this work. The results in terms of noise, conversion gain, dynamic range, obtained by means of infrared laser and X-rays, will be shown. In particular, the effects of the strip-to-strip coupling are studied in detail and it is found that the reduction of the coupling effects is one of the key factors for the development of the analogue front-end of Gotthard-II.

  8. Gyral high density on CT scan after head injury; [sup 123]I-IMP SPECT and MRI findings in three children

    Energy Technology Data Exchange (ETDEWEB)

    Abe, Takumi; Matsumoto, Kiyoshi (Showa Univ., Tokyo (Japan). School of Medicine); Sakamoto, Tetsuya; Aruga, Tohru

    1994-02-01

    The authors treated three children who had 'gyral high density' on plain CT scans after head injury with acute subdural hematoma. [sup 123]I-IMP SPECT (IMP) and MRI in the chronic stage were performed. All were males, about one year of age, with acute subdural hematoma. CT scan 48 hours after injury showed diffuse low density in the ipsilateral parenchyma with minimum midline shift, and IMP showed decreased activity in the same area. Plain CT scan 1 to 3 weeks after injury showed remarkably high density along the gyri in part of the same area. This area was markedly enhanced on CT with contrast medium and showed decreased blood flow on IMP. This high density area disappeared within 2 months after injury and the area concerned showed brain atrophy. In the chronic stage (after 6 months), only the high density area along the gyri seen in the CT scan showed MRI evidence of ishemia, but there was no definite evidence of hemorrhage. All three children had hemiplegia at the time of discharge. The gyral high density suggests ischemic brain, but the pathophysiological process might be different from that of so-called hemorrhagic infarction. Presumably, it is due to incomplete autoregulation, the incomplete blood-brain barrier and the sensitivity to stimulation of cerebral blood vessels in the brains of infants. The intensity and range of the gyral high density are considered to be important in estimating the future amount of atrophic change in the insulted brain and the resulting sequelae. (author).

  9. Proceedings of the workshop prospects for a 1 angstrom free-electron laser

    Energy Technology Data Exchange (ETDEWEB)

    Gallardo, J.C. (ed.)

    1990-01-01

    This report contains papers on the following topics free-electron laser theory, scaling relations and simulations; micro-wigglers; photocathode and switched power gun; applications; and summary of working groups.

  10. Proceedings of the workshop prospects for a 1 angstrom free-electron laser

    International Nuclear Information System (INIS)

    Gallardo, J.C.

    1990-01-01

    This report contains papers on the following topics free-electron laser theory, scaling relations and simulations; micro-wigglers; photocathode and switched power gun; applications; and summary of working groups

  11. Rethink! prototyping transdisciplinary concepts of prototyping

    CERN Document Server

    Nagy, Emilia; Stark, Rainer

    2016-01-01

    In this book, the authors describe the findings derived from interaction and cooperation between scientific actors employing diverse practices. They reflect on distinct prototyping concepts and examine the transformation of development culture in their fusion to hybrid approaches and solutions. The products of tomorrow are going to be multifunctional, interactive systems – and already are to some degree today. Collaboration across multiple disciplines is the only way to grasp their complexity in design concepts. This underscores the importance of reconsidering the prototyping process for the development of these systems, particularly in transdisciplinary research teams. “Rethinking Prototyping – new hybrid concepts for prototyping” was a transdisciplinary project that took up this challenge. The aim of this programmatic rethinking was to come up with a general concept of prototyping by combining innovative prototyping concepts, which had been researched and developed in three sub-projects: “Hybrid P...

  12. Free-Free Transitions of the e-H System Inside a Dense Plasma Irradiated by a Laser Field at Very Low Incident-Electron Energies

    Science.gov (United States)

    Bhatia, A. K.; Sinha, C.

    2012-01-01

    The free-free transition is studied for an electron-hydrogen atom in ground state when a low-energy electron (external) is injected into hydrogenic plasma in the presence of an external homogenous, monochromatic, and linearly polarized laser field. The effect of plasma screening is considered in the Debye-Huckel approximation. The calculations are performed in the soft photon limit. The incident electron is considered to be dressed by the laser field in a nonperturbative manner by choosing the Volkov solutions in both the initial and final channels. The space part of the scattering wave function for the electron is solved numerically by taking into account the electron exchange. The laser-assisted differential and total cross sections are calculated for single-photon absorption or emission and no-photon exchange in the soft photon limit, the laser intensity being much less than the atomic field intensity. The calculations have been carried out for various values of Debye parameter, ranging from 0.005 to 0.12. A strong suppression is noted in the laser-assisted cross sections as compared to the field-free situation. A significant difference is noted for the singlet and triplet cross sections. The suppression is much more in the triplet states.

  13. Strong plasma turbulence in the earth's electron foreshock

    Science.gov (United States)

    Robinson, P. A.; Newman, D. L.

    1991-01-01

    A quantitative model is developed to account for the distribution in magnitude and location of the intense plasma waves observed in the earth's electron foreshock given the observed rms levels of waves. In this model, nonlinear strong-turbulence effects cause solitonlike coherent wave packets to form and decouple from incoherent background beam-excited weak turbulence, after which they convect downstream with the solar wind while collapsing to scales as short as 100 m and fields as high as 2 V/m. The existence of waves with energy densities above the strong-turbulence wave-collapse threshold is inferred from observations from IMP 6 and ISEE 1 and quantitative agreement is found between the predicted distribution of fields in an ensemble of such wave packets and the actual field distribution observed in situ by IMP 6. Predictions for the polarization of plasma waves and the bandwidth of ion-sound waves are also consistent with the observations. It is shown that strong-turbulence effects must be incorporated in any comprehensive theory of the propagation and evolution of electron beams in the foreshock. Previous arguments against the existence of strong turbulence in the foreshock are refuted.

  14. Strong plasma turbulence in the earth's electron foreshock

    International Nuclear Information System (INIS)

    Robinson, P.A.; Newman, D.L.

    1991-01-01

    A quantitative model is developed to account for the distribution in magnitude and location of the intense plasma waves observed in the Earth's electron foreshock given the observed rms levels of waves. In this model, nonlinear strong-turbulence effects cause solitonlike coherent wave packets to form and decouple from incoherent background beam-excited weak turbulence, after which they convect downstream with the solar wind while collapsing to scales as short as 100 m and fields as high as 2 V m -1 . The existence of waves with energy densities above the strong-turbulence wave-collapse threshold is inferred from observations from IMP 6 and ISEE 1 and quantitative agreement is found between the predicted distribution of fields in an ensemble of such wave packets and the actual field distribution observed in situ by IMP 6. Predictions for the polarization of plasma waves and the bandwidth of ion-sound waves are also consistent with the observations. It is shown that strong-turbulence effects must be incorporated in any comprehensive theory of the propagation and evolution of electron beams in the foreshock. Previous arguments against the existence of strong turbulence in the foreshock are refuted

  15. On artefact-free reconstruction of low-energy (30–250 eV) electron holograms

    Energy Technology Data Exchange (ETDEWEB)

    Latychevskaia, Tatiana, E-mail: tatiana@physik.uzh.ch; Longchamp, Jean-Nicolas; Escher, Conrad; Fink, Hans-Werner

    2014-10-15

    Low-energy electrons (30–250 eV) have been successfully employed for imaging individual biomolecules. The most simple and elegant design of a low-energy electron microscope for imaging biomolecules is a lensless setup that operates in the holographic mode. In this work we address the problem associated with the reconstruction from the recorded holograms. We discuss the twin image problem intrinsic to inline holography and the problem of the so-called biprism-like effect specific to low-energy electrons. We demonstrate how the presence of the biprism-like effect can be efficiently identified and circumvented. The presented sideband filtering reconstruction method eliminates the twin image and allows for reconstruction despite the biprism-like effect, which we demonstrate on both, simulated and experimental examples. - Highlights: • Radiation damage-free imaging of individual biomolecules. • Elimination of the twin image in inline holograms. • Circumventing biprism-like effect in low-energy electron holograms. • Artefact-free reconstructions of low-energy electron holograms.

  16. On artefact-free reconstruction of low-energy (30–250 eV) electron holograms

    International Nuclear Information System (INIS)

    Latychevskaia, Tatiana; Longchamp, Jean-Nicolas; Escher, Conrad; Fink, Hans-Werner

    2014-01-01

    Low-energy electrons (30–250 eV) have been successfully employed for imaging individual biomolecules. The most simple and elegant design of a low-energy electron microscope for imaging biomolecules is a lensless setup that operates in the holographic mode. In this work we address the problem associated with the reconstruction from the recorded holograms. We discuss the twin image problem intrinsic to inline holography and the problem of the so-called biprism-like effect specific to low-energy electrons. We demonstrate how the presence of the biprism-like effect can be efficiently identified and circumvented. The presented sideband filtering reconstruction method eliminates the twin image and allows for reconstruction despite the biprism-like effect, which we demonstrate on both, simulated and experimental examples. - Highlights: • Radiation damage-free imaging of individual biomolecules. • Elimination of the twin image in inline holograms. • Circumventing biprism-like effect in low-energy electron holograms. • Artefact-free reconstructions of low-energy electron holograms

  17. 7. Seminar of the IIE-IMP-ININ on technological specialities. Topic 8: Analytical Chemistry

    International Nuclear Information System (INIS)

    1994-01-01

    With the purpose to give continuity to the exchange of experiences and to impel the development of common specialties among IIE-ININ-IMP, the VII Seminary was held in Mexico City on September 7, 1994. In the event were present 163 researchers of the three participant Institutions as well as representative persons of invited institutions. The objective of this Seminary was to relate the researchers of a common branch, with the idea that the specialists made an exchange of experiences, in order to establish cooperation routes. The event was arranged in 11 working tables, with a total of 111 papers: 43 of these papers were from IIE, 42 from IMP, 22 from ININ and 4 from invited entities. During the Seminary, the 11 working tables has sessions simultaneously, and each one of the papers were discussed at the time that possible future cooperating inter institutional actions were examined. The conclusions of the Seminary were exposed in a plenary session, in the presence of the directing boards of the three participant Institutions

  18. First mm-wave generation in the FOM free electron maser

    NARCIS (Netherlands)

    Verhoeven, A. G. A.; Bongers, W. A.; Bratman, V. L.; Caplan, M.; Denisov, G. G.; van der Geer, C. A. J.; Manintveld, P.; Poelman, A. J.; Plomp, J.; Savilov, A. V.; Smeets, P. H. M.; Sterk, A. B.; Urbanus, W. H.

    1999-01-01

    A free electron maser (FEM) has been built as a pilot mm-wave source for applications on future fusion research devices such as international tokamak experimental reactor (ITER), A unique feature of the Dutch FEM is the possibility to tune the frequency over the entire range from 130 to 260 GHz at

  19. Saturation mechanism and improvement of conversion efficiency of free electron laser

    International Nuclear Information System (INIS)

    Taguchi, T.; Mima, K.; Mochizuki, T.

    1980-01-01

    Saturation mechanisms of free electron laser are investigated in the Compton regime. It is found that the saturation occurs due to quasi-linear energy spreading of electron beam in the case of many mode excitation. The energy conversion efficiency remains low even if many modes are taken into account. For improvement of the conversion efficiency, effects of reacceleration by a traveling wave are investigated and turn out to increase the efficiency up to more than 50%. (author)

  20. Field Emitter Arrays for a Free Electron Laser Application

    CERN Document Server

    Shing-Bruce-Li, Kevin; Ganter, Romain; Gobrecht, Jens; Raguin, Jean Yves; Rivkin, Leonid; Wrulich, Albin F

    2004-01-01

    The development of a new electron gun with the lowest possible emittance would help reducing the total length and cost of a free electron laser. Field emitter arrays (FEAs) are an attractive technology for electron sources of ultra high brightness. Indeed, several thousands of microscopic tips can be deposited on a 1 mm diameter area. Electrons are then extracted by applying voltage to a first grid layer close to the tip apexes, the so called gate layer, and focused by a second grid layer one micrometer above the tips. The typical aperture diameter of the gate and the focusing layer is in the range of one micrometer. One challenge for such cathodes is to produce peak currents in the ampere range since the usual applications of FEAs require less than milliampere. Encouraging peak current performances have been obtained by applying voltage pulses at low frequency between gate and tips. In this paper we report on different tip materials available on the market: diamond FEAs from Extreme Devices Inc., ZrC single ...