WorldWideScience

Sample records for prototype handheld gamma

  1. A novel fully integrated handheld gamma camera

    International Nuclear Information System (INIS)

    Massari, R.; Ucci, A.; Campisi, C.; Scopinaro, F.; Soluri, A.

    2016-01-01

    In this paper, we present an innovative, fully integrated handheld gamma camera, namely designed to gather in the same device the gamma ray detector with the display and the embedded computing system. The low power consumption allows the prototype to be battery operated. To be useful in radioguided surgery, an intraoperative gamma camera must be very easy to handle since it must be moved to find a suitable view. Consequently, we have developed the first prototype of a fully integrated, compact and lightweight gamma camera for radiopharmaceuticals fast imaging. The device can operate without cables across the sterile field, so it may be easily used in the operating theater for radioguided surgery. The prototype proposed consists of a Silicon Photomultiplier (SiPM) array coupled with a proprietary scintillation structure based on CsI(Tl) crystals. To read the SiPM output signals, we have developed a very low power readout electronics and a dedicated analog to digital conversion system. One of the most critical aspects we faced designing the prototype was the low power consumption, which is mandatory to develop a battery operated device. We have applied this detection device in the lymphoscintigraphy technique (sentinel lymph node mapping) comparing the results obtained with those of a commercial gamma camera (Philips SKYLight). The results obtained confirm a rapid response of the device and an adequate spatial resolution for the use in the scintigraphic imaging. This work confirms the feasibility of a small gamma camera with an integrated display. This device is designed for radioguided surgery and small organ imaging, but it could be easily combined into surgical navigation systems.

  2. A novel fully integrated handheld gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Massari, R.; Ucci, A.; Campisi, C. [Biostructure and Bioimaging Institute (IBB), National Research Council of Italy (CNR), Rome (Italy); Scopinaro, F. [University of Rome “La Sapienza”, S. Andrea Hospital, Rome (Italy); Soluri, A., E-mail: alessandro.soluri@ibb.cnr.it [Biostructure and Bioimaging Institute (IBB), National Research Council of Italy (CNR), Rome (Italy)

    2016-10-01

    In this paper, we present an innovative, fully integrated handheld gamma camera, namely designed to gather in the same device the gamma ray detector with the display and the embedded computing system. The low power consumption allows the prototype to be battery operated. To be useful in radioguided surgery, an intraoperative gamma camera must be very easy to handle since it must be moved to find a suitable view. Consequently, we have developed the first prototype of a fully integrated, compact and lightweight gamma camera for radiopharmaceuticals fast imaging. The device can operate without cables across the sterile field, so it may be easily used in the operating theater for radioguided surgery. The prototype proposed consists of a Silicon Photomultiplier (SiPM) array coupled with a proprietary scintillation structure based on CsI(Tl) crystals. To read the SiPM output signals, we have developed a very low power readout electronics and a dedicated analog to digital conversion system. One of the most critical aspects we faced designing the prototype was the low power consumption, which is mandatory to develop a battery operated device. We have applied this detection device in the lymphoscintigraphy technique (sentinel lymph node mapping) comparing the results obtained with those of a commercial gamma camera (Philips SKYLight). The results obtained confirm a rapid response of the device and an adequate spatial resolution for the use in the scintigraphic imaging. This work confirms the feasibility of a small gamma camera with an integrated display. This device is designed for radioguided surgery and small organ imaging, but it could be easily combined into surgical navigation systems.

  3. Direction-Sensitive Hand-Held Gamma-Ray Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Mukhopadhyay, S.

    2012-10-04

    A novel, light-weight, hand-held gamma-ray detector with directional sensitivity is being designed. The detector uses a set of multiple rings around two cylindrical surfaces, which provides precise location of two interaction points on two concentric cylindrical planes, wherefrom the source location can be traced back by back projection and/or Compton imaging technique. The detectors are 2.0 × 2.0 mm europium-doped strontium iodide (SrI2:Eu2+) crystals, whose light output has been measured to exceed 120,000 photons/MeV, making it one of the brightest scintillators in existence. The crystal’s energy resolution, less than 3% at 662 keV, is also excellent, and the response is highly linear over a wide range of gamma-ray energies. The emission of SrI2:Eu2+ is well matched to both photo-multiplier tubes and blue-enhanced silicon photodiodes. The solid-state photomultipliers used in this design (each 2.0 × 2.0 mm) are arrays of active pixel sensors (avalanche photodiodes driven beyond their breakdown voltage in reverse bias); each pixel acts as a binary photon detector, and their summed output is an analog representation of the total photon energy, while the individual pixel accurately defines the point of interaction. A simple back-projection algorithm involving cone-surface mapping is being modeled. The back projection for an event cone is a conical surface defining the possible location of the source. The cone axis is the straight line passing through the first and second interaction points.

  4. Mobile robot prototype detector of gamma radiation

    International Nuclear Information System (INIS)

    Vazquez C, R.M.; Duran V, M. D.; Jardon M, C. I.

    2014-10-01

    In this paper the technological development of a mobile robot prototype detector of gamma radiation is shown. This prototype has been developed for the purpose of algorithms implementation for the applications of terrestrial radiation monitoring of exposed sources, search for missing radioactive sources, identification and delineation of radioactive contamination areas and distribution maps generating of radioactive exposure. Mobile robot detector of radiation is an experimental technology development platform to operate in laboratory environment or flat floor facilities. The prototype integrates a driving section of differential configuration robot on wheels, a support mechanism and rotation of shielded detector, actuator controller cards, acquisition and processing of sensor data, detection algorithms programming and control actuators, data recording (Data Logger) and data transmission in wireless way. The robot in this first phase is remotely operated in wireless way with a range of approximately 150 m line of sight and can extend that range to 300 m or more with the use of signal repeaters. The gamma radiation detection is performed using a Geiger detector shielded. Scan detection is performed at various time sampling periods and diverse positions of discrete or continuous angular orientation on the horizon. The captured data are geographical coordinates of robot GPS (latitude and longitude), orientation angle of shield, counting by sampling time, date, hours, minutes and seconds. The data is saved in a file in the Micro Sd memory on the robot. They are also sent in wireless way by an X Bee card to a remote station that receives for their online monitoring on a laptop through an acquisition program by serial port on Mat Lab. Additionally a voice synthesizing card with a horn, both in the robot, periodically pronounced in Spanish, data length, latitude, orientation angle of shield and detected accounts. (Author)

  5. Structural behaviour of the GAMMA 60 prototype

    Energy Technology Data Exchange (ETDEWEB)

    Falchetta, M.; Matano, F. [ENEA C.R.E., Rome (Italy); Botta, G.; Cavaliere, M. [ENEL C.R.E.,Milano (Italy); Doman, G.S.; Golinelli, S. [West V., Rome (Italy); Viani, S. [ISMES (Italy)

    1996-12-31

    A joint test campaign started in April 1993 on the GAMMA 60 broad range variable speed, yaw controlled, 1500 kW wind turbine prototype, operating at the ENEL test field of Alta Nurra - Sardinia. As part of the test campaign the structural behaviour of the machine has been investigated and the aeroelastic simulation of the machine using GAROS code has been improved and verified with available data. The experimental loads, measured with a number of strain gages at various locations in the rotor, yaw actuator and tower have been compared, as far as possible, with the design loads. No major structural problems have been detected during operation, while measured loads and stress levels are generally comparable with the design assumptions. In addition, substantial experience in the use of the code has been gained, increasing confidence level of predictions. (author)

  6. Criteria for a comparative assessment on handheld gamma-ray measurement tools

    International Nuclear Information System (INIS)

    Feichtinger, J.; Schwaiger, M.; Schmitzer, C.; Kindl, P.

    2001-01-01

    Full text: The radionuclide laboratories at the Austrian Research Centres Seibersdorf are strongly involved in radiation protection of public and employees as well as in environmental monitoring with special concern to gamma spectrometric measurements. Hence, field measurements and therefore the subject of hand-held measurement devices is a topic of main interest. Taking into consideration, that these hand-held measurement tool are further used in critical and sensitive operations, as for example by the IAEA Safeguards or by CTBTO On-Site inspectors, a standard for characterising these gamma measurement tools seems to be sound as necessary. The poster presents a set of technical criteria as well as limiting values, which allows an objective comparison of hand-held measurement devices. The criteria can be divided into three individual parts: radiometric characteristics, ergonomics and usability in field operations. The main criteria for testing the radiometry performance of hand-held measurement devices are sensitivity, efficiency, energy response, energy resolution and nuclide identification or not identification (if necessary), detection probability, dose rate indication, uncertainty, etc. The ergonomic test contains as dominating parts handling and quality of the manual. To evaluate the applicability in field operations different environmental conditions (e.g. light conditions, temperature range, moisture...) as well as battery lifetime and weight should be taken into account. These criteria may vary in dependence of the requirements or limitations given by various external conditions, but still a standard to evaluate and will give the opportunity to provide an objective comparison. (author)

  7. A Prototype for Passive Gamma Emission Tomography

    International Nuclear Information System (INIS)

    Honkamaa, T.; Levai, F.; Berndt, R.; Schwalbach, P.; Vaccaro, S.; ); Turunen, A.

    2015-01-01

    Combined efforts of multiple stakeholders of the IAEA Support Programme task JNT 1510: ''Prototype of passive gamma emission tomograph (PGET)'', resulted in the design, manufacturing and extensive testing of an advanced verification tool for partial defect testing on light water reactor spent fuel. The PGET has now reached a proven capability of detecting a single missing or substituted pin inside a BWR and VVER-440 fuel assemblies. The task started in 2004 and it is planned to be finished this year. The PGET head consists of two banks of 104 CdTe detectors each with integrated data acquisition electronics. The CdTe detectors are embedded in tungsten collimators which can be rotated around the fuel element using an integrated stepping motor mounted on a rotating table. All components are packed inside a toroid watertight enclosure. Control, data acquisition and image reconstruction analysis is fully computerized and automated. The design of the system is transportable and suitable for safeguards verifications in spent fuel ponds anywhere. Four test campaigns have been conducted. In 2009, the first test in Ringhals NPP failed collecting data but demonstrated suitability of the PGET for field deployments. Subsequent tests on fuel with increasing complexity were all successful (Ispra, Italy (2012), Olkiluoto, Finland (2013) and Loviisa, Finland (2014)). The paper will present the PGET design, results obtained from the test campaigns and mention also drawbacks that were experienced in the project. The paper also describes further tests which would allow evaluating the capabilities and limitations of the method and the algorithm used. Currently, the main technical shortcoming is long acquisition time, due to serial control and readout of detectors. With redesigned electronics it can be expected that the system would be able to verify a VVER-440 assembly in five minutes, which meets the IAEA user requirements. (author)

  8. Potential role of a new hand-held miniature gamma camera in performing minimally invasive parathyroidectomy

    Energy Technology Data Exchange (ETDEWEB)

    Ortega, Joaquin; Lledo, Salvador [University of Valencia, Clinic University Hospital, Department of Surgery, Valencia (Spain); Ferrer-Rebolleda, Jose [Clinic University Hospital, Department of Nuclear Medicine, Valencia (Spain); Cassinello, Norberto [Clinic University Hospital, Unit of Endocrinologic and Bariatric Surgery, Valencia (Spain)

    2007-02-15

    Sestamibi scans have increased the use of minimally invasive parathyroidectomy (MIP) to treat primary hyperparathyroidism (PHPT) when caused by a parathyroid single adenoma. The greatest concern for surgeons remains the proper identification of pathological glands in a limited surgical field. We have studied the usefulness of a new hand-held miniature gamma camera (MGC) when used intraoperatively to locate parathyroid adenomas. To our knowledge this is the first report published on this subject in the scientific literature. Five patients with PHPT secondary to a single adenoma, positively diagnosed by preoperative sestamibi scans, underwent a MIP. A gamma probe for radioguided surgery and the new hand-held MGC were used consecutively to locate the pathological glands. This new MGC has a module composed of a high-resolution interchangeable collimator and a CsI(Na) scintillating crystal. It has dimensions of around 15 cm x 8 cm x 9 cm and weighs 1 kg. The intraoperative assay of PTH (ioPTH) was used to confirm the complete resection of pathological tissue. All cases were operated on successfully by a MIP. The ioPTH confirmed the excision of all pathological tissues. The MGC proved its usefulness in all patients, even in a difficult case in which the first attempt with the gamma probe failed. In all cases it offered real-time accurate intraoperative images. The hand-held MGC is a useful instrument in MIP for PHPT. It may be used to complement the standard tools used to date, or may even replace them, at least in selected cases of single adenomas. (orig.)

  9. Potential role of a new hand-held miniature gamma camera in performing minimally invasive parathyroidectomy

    International Nuclear Information System (INIS)

    Ortega, Joaquin; Lledo, Salvador; Ferrer-Rebolleda, Jose; Cassinello, Norberto

    2007-01-01

    Sestamibi scans have increased the use of minimally invasive parathyroidectomy (MIP) to treat primary hyperparathyroidism (PHPT) when caused by a parathyroid single adenoma. The greatest concern for surgeons remains the proper identification of pathological glands in a limited surgical field. We have studied the usefulness of a new hand-held miniature gamma camera (MGC) when used intraoperatively to locate parathyroid adenomas. To our knowledge this is the first report published on this subject in the scientific literature. Five patients with PHPT secondary to a single adenoma, positively diagnosed by preoperative sestamibi scans, underwent a MIP. A gamma probe for radioguided surgery and the new hand-held MGC were used consecutively to locate the pathological glands. This new MGC has a module composed of a high-resolution interchangeable collimator and a CsI(Na) scintillating crystal. It has dimensions of around 15 cm x 8 cm x 9 cm and weighs 1 kg. The intraoperative assay of PTH (ioPTH) was used to confirm the complete resection of pathological tissue. All cases were operated on successfully by a MIP. The ioPTH confirmed the excision of all pathological tissues. The MGC proved its usefulness in all patients, even in a difficult case in which the first attempt with the gamma probe failed. In all cases it offered real-time accurate intraoperative images. The hand-held MGC is a useful instrument in MIP for PHPT. It may be used to complement the standard tools used to date, or may even replace them, at least in selected cases of single adenomas. (orig.)

  10. Gamma-ray detectors for intelligent, hand-held radiation monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1983-01-01

    Small radiation detectors based on HgI 2 , bismuth germanate (BGO), plastic, or NaI(Tl) detector materials were evaluated for use in small, lighweight radiation monitors. The two denser materials, HgI 2 and BGO, had poor resolution at low-energy and thus performed less well than NaI(Tl) in detecting low-energy gamma rays from bare, enriched uranium. The plastic scintillator, a Compton recoil detector, also performed less well at low gamma-ray energy. Two small NaI(Tl) detectors were suitable for detecting bare uranium and sheilded plutonium. One became part of a new lightweight hand-held monitor and the other found uses as a pole-mounted detector for monitoring hard-to-reach locations

  11. Handheld real-time volumetric 3-D gamma-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Haefner, Andrew, E-mail: ahaefner@lbl.gov [Lawrence Berkeley National Lab – Applied Nuclear Physics, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Barnowski, Ross [Department of Nuclear Engineering, UC Berkeley, 4155 Etcheverry Hall, MC 1730, Berkeley, CA 94720 (United States); Luke, Paul; Amman, Mark [Lawrence Berkeley National Lab – Applied Nuclear Physics, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Vetter, Kai [Department of Nuclear Engineering, UC Berkeley, 4155 Etcheverry Hall, MC 1730, Berkeley, CA 94720 (United States); Lawrence Berkeley National Lab – Applied Nuclear Physics, 1 Cyclotron Road, Berkeley, CA 94720 (United States)

    2017-06-11

    This paper presents the concept of real-time fusion of gamma-ray imaging and visual scene data for a hand-held mobile Compton imaging system in 3-D. The ability to obtain and integrate both gamma-ray and scene data from a mobile platform enables improved capabilities in the localization and mapping of radioactive materials. This not only enhances the ability to localize these materials, but it also provides important contextual information of the scene which once acquired can be reviewed and further analyzed subsequently. To demonstrate these concepts, the high-efficiency multimode imager (HEMI) is used in a hand-portable implementation in combination with a Microsoft Kinect sensor. This sensor, in conjunction with open-source software, provides the ability to create a 3-D model of the scene and to track the position and orientation of HEMI in real-time. By combining the gamma-ray data and visual data, accurate 3-D maps of gamma-ray sources are produced in real-time. This approach is extended to map the location of radioactive materials within objects with unknown geometry.

  12. Integrated optical detection of autonomous capillary microfluidic immunoassays:a hand-held point-of-care prototype.

    Science.gov (United States)

    Novo, P; Chu, V; Conde, J P

    2014-07-15

    The miniaturization of biosensors using microfluidics has potential in enabling the development of point-of-care devices, with the added advantages of reduced time and cost of analysis with limits-of-detection comparable to those obtained through traditional laboratory techniques. Interfacing microfluidic devices with the external world can be difficult especially in aspects involving fluid handling and the need for simple sample insertion that avoids special equipment or trained personnel. In this work we present a point-of-care prototype system by integrating capillary microfluidics with a microfabricated photodiode array and electronic instrumentation into a hand-held unit. The capillary microfluidic device is capable of autonomous and sequential fluid flow, including control of the average fluid velocity at any given point of the analysis. To demonstrate the functionality of the prototype, a model chemiluminescence ELISA was performed. The performance of the integrated optical detection in the point-of-care prototype is equal to that obtained with traditional bench-top instrumentation. The photodiode signals were acquired, displayed and processed by a simple graphical user interface using a computer connected to the microcontroller through USB. The prototype performed integrated chemiluminescence ELISA detection in about 15 min with a limit-of-detection of ≈2 nM with an antibody-antigen affinity constant of ≈2×10(7) M(-1). Copyright © 2014 Elsevier B.V. All rights reserved.

  13. The Complimentary Role of Methoxy-Isobutyl-Isonitrile and Hand-Held Gamma Probe in Adamantinoma

    Science.gov (United States)

    Maharaj, Masha; Korowlay, Nisaar; Ellmann, Prof

    2016-01-01

    Adamantinoma is a rare locally aggressive osteolytic tumor that is found 90% of the time in the diaphysis of the tibia with the remaining lesions found in the fibula and long tubular bones. A case of adamantinoma of the tibia is presented. The added value of nuclear medicine investigations in the workup of this patient is described. A three-phase whole body 99mTc-methylene diphosphonate bone and a whole body 99mTc-methoxy-isobutyl-isonitrile scans were complimentary in the demarcation of viable bone tumor and the assessment of the remainder of the bone and soft tissue to exclude other sites. Intra-operative assistance with a hand-held gamma probe, guided the biopsy of the most metabolically active tumor tissue. Histology revealed a biphasic tumor composed of epithelial and fibrous components, in keeping with an adamantinoma. PMID:26912979

  14. Hanford beta-gamma personnel dosimeter prototypes and evaluation

    International Nuclear Information System (INIS)

    Fix, J.J.; Holbrook, K.L.; Soldat, K.L.

    1983-04-01

    Upgraded and modified Hanford dosimeter prototypes were evaluated for possible use at Hanford as a primary beta-gamma dosimeter. All prototypes were compatible with the current dosimeter card and holder design, as well as processing with the automated Hanford readers. Shallow- and deep-dose response was determined for selected prototypes using several beta sources, K-fluorescent x rays and filtered x-ray techniques. All prototypes included a neutron sensitive chip. A progressive evaluation of the performance of each of the upgrades to the current dosimeter is described. In general, the performance of the current dosimeter can be upgraded using individual chip sensitivity factors to improve precision and an improved algorithm to minimize bias. The performance of this dosimeter would be adequate to pass all categories of the ANSI N13.11 performance criteria for dosimeter procesors, provided calibration techniques compatible with irradiations adopted in the standard were conducted. The existing neutron capability of the dosimeter could be retained. Better dosimeter performance to beta-gamma radiation can be achieved by modifying the Hanford dosimeter so that four of the five chip positions are devoted to calculating these doses instead of the currently used two chip positions. A neutron sensitive chip was used in the 5th chip position, but all modified dosimeter prototypes would be incapable of discriminating between thermal and epithermal neutrons. An improved low energy beta response can be achieved for the current dosimeter and all prototypes considered by eliminating the security credential. Further improvement can be obtained by incorporating the 15-mil thick TLD-700 chips

  15. Analysis of spectra from portable handheld gamma-ray spectrometry for terrain comparative assessment

    International Nuclear Information System (INIS)

    Dias, Flávio; Lima, Marco; Sanjurjo-Sánchez, Jorge; Alves, Carlos

    2016-01-01

    Geological characteristics can have impacts on societal development by, e.g., geotechnical issues and radiological hazard levels. Due to urban sprawl, there is an increasing need for detailed geological assessment. In this work are analysed data from portable handheld gamma-ray spectra (K, eU and eTh) obtained in granitic and Silurian metaclastic outcrops as well as in an profile, roughly N–S, on soil covered terrains transecting a mapped contact between these rock types (the profile's northern extremity is at locations mapped as granite). Estimations from gamma-ray spectra were studied by univariate and multivariate analyses. K, eU and eTh values were higher on granite in relation to Silurian metaclastic rocks. The northern extremity of the profile showed clearly higher contents of eTh and this contrast was supported by univariate statistical tools (normality plot and Wilk–Shapiro test; boxplots). A ternary plot with the contribution of the elements to gamma-ray absorbed dose showed the separation of granite from Silurian metaclastic rocks with the former being nearer the eTh vertex. The points in the northern extremity of the profile are nearer the eTh vertex than the other points on the profile. These visual suggestions were supported by hierarchical cluster analysis, which was able to differentiate between granite and metaclastic outcrops and separate portions of the profile located on different terrains. Portable gamma-ray spectrometry showed, hence, the potential to distinguish granite and metaclastic terrains at a scale useful for engineering works. These results can also be useful for a first comparative zoning of radiological hazards (which are higher for granite). - Highlights: • Contents of K, eU and eTh were estimated by portable gamma-ray spectra. • Spectra were acquired on a profile across a soil covered granite/metaclastic contact. • Spectra were also collected on granite and Silurian metaclastic outcrops. • Obtained estimations were

  16. First demonstration of real-time gamma imaging by using a handheld Compton camera for particle therapy

    Energy Technology Data Exchange (ETDEWEB)

    Taya, T., E-mail: taka48138@ruri.waseda.jp [Research Institute for Science and Engineering, Waseda University, 3-4-1 Okubo, Shinjuku, Tokyo 169-8555 (Japan); Kataoka, J.; Kishimoto, A.; Iwamoto, Y.; Koide, A. [Research Institute for Science and Engineering, Waseda University, 3-4-1 Okubo, Shinjuku, Tokyo 169-8555 (Japan); Nishio, T. [Graduate School of Biomedical and Health Science, Hiroshima University, 1-2-3, Kasumi, Minami-ku, Hiroshima-shi, Hiroshima (Japan); Kabuki, S. [School of Medicine, Tokai University, 143 Shimokasuya, Isehara-shi, Kanagawa (Japan); Inaniwa, T. [National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba-shi, Chiba (Japan)

    2016-09-21

    The use of real-time gamma imaging for cancer treatment in particle therapy is expected to improve the accuracy of the treatment beam delivery. In this study, we demonstrated the imaging of gamma rays generated by the nuclear interactions during proton irradiation, using a handheld Compton camera (14 cm×15 cm×16 cm, 2.5 kg) based on scintillation detectors. The angular resolution of this Compton camera is ∼8° at full width at half maximum (FWHM) for a {sup 137}Cs source. We measured the energy spectra of the gamma rays using a LaBr{sub 3}(Ce) scintillator and photomultiplier tube, and using the handheld Compton camera, performed image reconstruction when using a 70 MeV proton beam to irradiate a water, Ca(OH){sub 2}, and polymethyl methacrylate (PMMA) phantom. In the energy spectra of all three phantoms, we found an obvious peak at 511 keV, which was derived from annihilation gamma rays, and in the energy spectrum of the PMMA phantom, we found another peak at 718 keV, which contains some of the prompt gamma rays produced from {sup 10}B. Therefore, we evaluated the peak positions of the projection from the reconstructed images of the PMMA phantom. The differences between the peak positions and the Bragg peak position calculated using simulation are 7 mm±2 mm and 3 mm±8 mm, respectively. Although we could quickly acquire online gamma imaging of both of the energy ranges during proton irradiation, we cannot arrive at a clear conclusion that prompt gamma rays sufficiently trace the Bragg peak from these results because of the uncertainty given by the spatial resolution of the Compton camera. We will develop a high-resolution Compton camera in the near future for further study. - Highlights: • Gamma imaging during proton irradiation by a handheld Compton camera is demonstrated. • We were able to acquire the online gamma-ray images quickly. • We are developing a high resolution Compton camera for range verification.

  17. Development of a low cost, GPS-based upgrade to a standard handheld gamma detector for mapping environmental radioactive contamination.

    Science.gov (United States)

    Paridaens, J

    2006-02-01

    A low cost extension to a standard handheld radiation monitor was developed, allowing one to perform outdoor georeferenced gamma measurements. It consists of a commercial wireless Bluetooth GPS receiver, a commercial RS-232 to Bluetooth converter combined with a standard Bluetooth enabled pocket personal computer (PPC). The system is intended for use in difficult to access areas, typically for foot campaigns. As the operator walks, a straightforward homemade visual basic program alternately reads GPS position and gamma dose rate into the PPC, creating a data log. This allows a single operator on foot to map between 50 and 200 ha of environmental radiation per day in very rugged areas, depending on the accessibility of the terrain and the detail required. On a test field with known contamination, a spatial precision of about 5-10 m was obtainable. The device was also used to reveal complex contamination patterns in the flooding zones of a radioactively contaminated small river.

  18. Mobile robot prototype detector of gamma radiation; Prototipo de robot movil detector de radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez C, R.M. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Duran V, M. D.; Jardon M, C. I., E-mail: raulmario.vazquez@inin.gob.mx [Tecnologico de Estudios Superiores de Villa Guerrero, Carretera Federal Toluca-Ixtapan de la Sal Km. 64.5, La Finca Villa Guerrero, Estado de Mexico (Mexico)

    2014-10-15

    In this paper the technological development of a mobile robot prototype detector of gamma radiation is shown. This prototype has been developed for the purpose of algorithms implementation for the applications of terrestrial radiation monitoring of exposed sources, search for missing radioactive sources, identification and delineation of radioactive contamination areas and distribution maps generating of radioactive exposure. Mobile robot detector of radiation is an experimental technology development platform to operate in laboratory environment or flat floor facilities. The prototype integrates a driving section of differential configuration robot on wheels, a support mechanism and rotation of shielded detector, actuator controller cards, acquisition and processing of sensor data, detection algorithms programming and control actuators, data recording (Data Logger) and data transmission in wireless way. The robot in this first phase is remotely operated in wireless way with a range of approximately 150 m line of sight and can extend that range to 300 m or more with the use of signal repeaters. The gamma radiation detection is performed using a Geiger detector shielded. Scan detection is performed at various time sampling periods and diverse positions of discrete or continuous angular orientation on the horizon. The captured data are geographical coordinates of robot GPS (latitude and longitude), orientation angle of shield, counting by sampling time, date, hours, minutes and seconds. The data is saved in a file in the Micro Sd memory on the robot. They are also sent in wireless way by an X Bee card to a remote station that receives for their online monitoring on a laptop through an acquisition program by serial port on Mat Lab. Additionally a voice synthesizing card with a horn, both in the robot, periodically pronounced in Spanish, data length, latitude, orientation angle of shield and detected accounts. (Author)

  19. Development of a low cost, GPS-based upgrade to a standard handheld gamma detector for mapping environmental radioactive contamination

    International Nuclear Information System (INIS)

    Paridaens, J.

    2006-01-01

    A low cost extension to a standard handheld radiation monitor was developed, allowing one to perform outdoor georeferenced gamma measurements. It consists of a commercial wireless Bluetooth[reg] GPS receiver, a commercial RS-232 to Bluetooth[reg] converter combined with a standard Bluetooth[reg] enabled pocket personal computer (PPC). The system is intended for use in difficult to access areas, typically for foot campaigns. As the operator walks, a straightforward homemade visual basic program alternately reads GPS position and gamma dose rate into the PPC, creating a data log. This allows a single operator on foot to map between 50 and 200 ha of environmental radiation per day in very rugged areas, depending on the accessibility of the terrain and the detail required. On a test field with known contamination, a spatial precision of about 5-10 m was obtainable. The device was also used to reveal complex contamination patterns in the flooding zones of a radioactively contaminated small river

  20. Development of a low cost, GPS-based upgrade to a standard handheld gamma detector for mapping environmental radioactive contamination

    Energy Technology Data Exchange (ETDEWEB)

    Paridaens, J. [Belgian Nuclear Research Centre, SCK.CEN, Boeretang 200, B2400 Mol (Belgium)]. E-mail: jparidae@sckcen.be

    2006-02-15

    A low cost extension to a standard handheld radiation monitor was developed, allowing one to perform outdoor georeferenced gamma measurements. It consists of a commercial wireless Bluetooth[reg] GPS receiver, a commercial RS-232 to Bluetooth[reg] converter combined with a standard Bluetooth[reg] enabled pocket personal computer (PPC). The system is intended for use in difficult to access areas, typically for foot campaigns. As the operator walks, a straightforward homemade visual basic program alternately reads GPS position and gamma dose rate into the PPC, creating a data log. This allows a single operator on foot to map between 50 and 200 ha of environmental radiation per day in very rugged areas, depending on the accessibility of the terrain and the detail required. On a test field with known contamination, a spatial precision of about 5-10 m was obtainable. The device was also used to reveal complex contamination patterns in the flooding zones of a radioactively contaminated small river.

  1. An improved hand-held four-detector gamma-probe for radioassisted oncological surgery

    CERN Document Server

    Dusi, W; Bollini, D; Moroni, C; Ricard, M

    2000-01-01

    The performance of an improved intraoperative gamma-probe for radioassisted oncological surgery is presented and discussed. The probe is based on a square array of four 5x5 mm sup 2 coplanar CdTe room temperature semiconductor detectors and each detector has an independent read out electronic chain, allowing an original handling of the signal. Therefore, the search for gamma-emission hot points may be carried out in two different, independent ways: (1) Finding out the position of the probe corresponding to the maximum value of the total counting rate, on the basis of a trial and error procedure (typical for the conventional probe; (2) Finding out the position of the probe where both the differences between the counting rate performed by orthogonal, adjacent halves of the array vanish (differential method). This makes the new probe sensitive to the bidimensional gradient of the gamma-ray flux, measured on the scanned plane. Furthermore, the algebraic sign of the difference indicates in which direction the prob...

  2. Prototype system for proton beam range measurement based on gamma electron vertex imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Han Rim [Neutron Utilization Technology Division, Korea Atomic Energy Research Institute, 111, Daedeok-daero 989beon-gil, Yuseong-gu, Daejeon 34057 (Korea, Republic of); Kim, Sung Hun; Park, Jong Hoon [Department of Nuclear Engineering, Hanyang University, Seongdong-gu, Seoul 04763 (Korea, Republic of); Jung, Won Gyun [Heavy-ion Clinical Research Division, Korean Institute of Radiological & Medical Sciences, Seoul 01812 (Korea, Republic of); Lim, Hansang [Department of Electronics Convergence Engineering, Kwangwoon University, Seoul 01897 (Korea, Republic of); Kim, Chan Hyeong, E-mail: chkim@hanyang.ac.kr [Department of Nuclear Engineering, Hanyang University, Seongdong-gu, Seoul 04763 (Korea, Republic of)

    2017-06-11

    In proton therapy, for both therapeutic effectiveness and patient safety, it is very important to accurately measure the proton dose distribution, especially the range of the proton beam. For this purpose, recently we proposed a new imaging method named gamma electron vertex imaging (GEVI), in which the prompt gammas emitting from the nuclear reactions of the proton beam in the patient are converted to electrons, and then the converted electrons are tracked to determine the vertices of the prompt gammas, thereby producing a 2D image of the vertices. In the present study, we developed a prototype GEVI system, including dedicated signal processing and data acquisition systems, which consists of a beryllium plate (= electron converter) to convert the prompt gammas to electrons, two double-sided silicon strip detectors (= hodoscopes) to determine the trajectories of those converted electrons, and a plastic scintillation detector (= calorimeter) to measure their kinetic energies. The system uses triple coincidence logic and multiple energy windows to select only the events from prompt gammas. The detectors of the prototype GEVI system were evaluated for electronic noise level, energy resolution, and time resolution. Finally, the imaging capability of the GEVI system was tested by imaging a {sup 90}Sr beta source, a {sup 60}Co gamma source, and a 45-MeV proton beam in a PMMA phantom. The overall results of the present study generally show that the prototype GEVI system can image the vertices of the prompt gammas produced by the proton nuclear interactions.

  3. Performance evaluation of a hand-held, semiconductor (CdZnTe)-based gamma camera

    CERN Document Server

    Abe, A; Lee, J; Oka, T; Shizukuishi, K; Kikuchi, T; Inoue, T; Jimbo, M; Ryuo, H; Bickel, C

    2003-01-01

    We have designed and developed a small field of view gamma camera, the eZ SCOPE, based on use of a CdZnTe semiconductor. This device utilises proprietary signal processing technology and an interface to a computer-based imaging system. The purpose of this study was to evaluate the performance of the eZ scope in comparison with currently employed gamma camera technology. The detector is a single wafer of 5-mm-thick CdZnTe that is divided into a 16 x 16 array (256 pixels). The sensitive area of the detector is a square of dimension 3.2 cm. Two parallel-hole collimators are provided with the system and have a matching (256 hole) pattern to the CdZnTe detector array: a low-energy, high-resolution parallel-hole (LEHR) collimator fabricated of lead and a low-energy, high-sensitivity parallel-hole (LEHS) collimator fabricated of tungsten. Performance measurements and the data analysis were done according to the procedures of the NEMA standard. We also studied the long-term stability of the system with continuous use...

  4. Experimentation with a prototype incinerator for beta-gamma waste

    International Nuclear Information System (INIS)

    Farber, M.G.; Lewandowski, K.E.; Becker, G.W.

    1982-01-01

    A test facility for the incineration of suspect and low-level beta-gamma waste has been built and operated at the Savannah River Laboratory. The processing steps include waste feeding, incineration, ash residue packaging, and off-gas cleanup. Demonstration of the full-scale (180 kg/hr) facility with nonradioactive, simulated waste is currently in progress. At the present time, over nine metric tons of material including rubber, polyethylene, and cellulose have been incinerated during three burning campaigns. A comprehensive test program of solid and liquid waste incineration is being implemented. The data from the research program is providing the technical basis for a phase of testing with low-level beta-gamma waste generated at the Savannah River Plant

  5. Gamma-ray tracking: Characterisation of the AGATA symmetric prototype detectors

    International Nuclear Information System (INIS)

    Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Dimmock, M.R.; Nelson, L.; Nolan, P.J.; Rigby, S.; Lazarus, I.; Simpson, J.; Medina, P.; Santos, C.; Parisel, C.

    2007-01-01

    Each major technical advance in gamma-ray detection devices has resulted in significant new insights into the structure of atomic nuclei. The next major step in gamma-ray spectroscopy involves achieving the goal of a 4pi ball of Germanium detectors by using the technique of gamma-ray energy tracking in electrically segmented Germanium crystals. The resulting spectrometer will have an unparalleled level of detection power for nuclear electromagnetic radiation. Collaborations have been established in Europe (AGATA) [J. Simpson, Acta Phys. Pol. B 36 (2005) 1383. ] and the USA (GRETA/GRETINA) to build gamma-ray tracking spectrometers. This paper discusses the performance of the AGATA (Advanced Gamma Tracking Array) symmetric prototype detectors that have been tested at University of Liverpool. The use of a fully digital data acquisition system has allowed detector charge pulse shapes from a selection of well defined photon interaction positions to be analysed, yielding important information on the position sensitivity of the detector

  6. Gamma-ray tracking: Characterisation of the AGATA symmetric prototype detectors

    Energy Technology Data Exchange (ETDEWEB)

    Boston, A.J. [Oliver Lodge Laboratory, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom)]. E-mail: ajboston@liv.ac.uk; Boston, H.C. [Oliver Lodge Laboratory, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Cresswell, J.R. [Oliver Lodge Laboratory, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Dimmock, M.R. [Oliver Lodge Laboratory, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Nelson, L. [Oliver Lodge Laboratory, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Nolan, P.J. [Oliver Lodge Laboratory, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Rigby, S. [Oliver Lodge Laboratory, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Lazarus, I. [STFC Daresbury Laboratory, Daresbury, Warrington WA4 4AD (United Kingdom); Simpson, J. [STFC Daresbury Laboratory, Daresbury, Warrington WA4 4AD (United Kingdom); Medina, P. [Institut de Recherches Subatomiques, Strasbourg BP28 67037 (France); Santos, C. [Institut de Recherches Subatomiques, Strasbourg BP28 67037 (France); Parisel, C. [Institut de Recherches Subatomiques, Strasbourg BP28 67037 (France)

    2007-08-15

    Each major technical advance in gamma-ray detection devices has resulted in significant new insights into the structure of atomic nuclei. The next major step in gamma-ray spectroscopy involves achieving the goal of a 4pi ball of Germanium detectors by using the technique of gamma-ray energy tracking in electrically segmented Germanium crystals. The resulting spectrometer will have an unparalleled level of detection power for nuclear electromagnetic radiation. Collaborations have been established in Europe (AGATA) [J. Simpson, Acta Phys. Pol. B 36 (2005) 1383. ] and the USA (GRETA/GRETINA) to build gamma-ray tracking spectrometers. This paper discusses the performance of the AGATA (Advanced Gamma Tracking Array) symmetric prototype detectors that have been tested at University of Liverpool. The use of a fully digital data acquisition system has allowed detector charge pulse shapes from a selection of well defined photon interaction positions to be analysed, yielding important information on the position sensitivity of the detector.

  7. A Compton camera prototype for prompt gamma medical imaging

    Directory of Open Access Journals (Sweden)

    Thirolf P.G.

    2016-01-01

    Full Text Available Compton camera prototype for a position-sensitive detection of prompt γ rays from proton-induced nuclear reactions is being developed in Garching. The detector system allows to track the Comptonscattered electrons. The camera consists of a monolithic LaBr3:Ce scintillation absorber crystal, read out by a multi-anode PMT, preceded by a stacked array of 6 double-sided silicon strip detectors acting as scatterers. The LaBr3:Ce crystal has been characterized with radioactive sources. Online commissioning measurements were performed with a pulsed deuteron beam at the Garching Tandem accelerator and with a clinical proton beam at the OncoRay facility in Dresden. The determination of the interaction point of the photons in the monolithic crystal was investigated.

  8. Prototype of an expert system to help nuclide identification in gamma spectrum analysis

    International Nuclear Information System (INIS)

    Jayanthi, Kasi Annapurna; Corcuera, Raquel Paviotti; Oliveira, Gina Maira B.

    1995-01-01

    This report describes the development and use of IDENT, prototype of an expert system that helps the researcher to identify radionuclides in gamma-ray spectroscopy. Normally the method adopted by the researcher is iterative, time consuming and becomes complicated in the analysis of large and complex gamma-ray spectra. The present expert system is based on the knowledge transmitted by expert and specialists in this area and the results show that it is helpful for researches who perform nuclide identification through gamma-ray spectroscopy. The gamma-ray spectrum of a material sample with about 140 peaks would take about a week or two be analysed by a specialist. The same task can be done in a few minutes using this expert system. (author). 14 refs., 2 figs

  9. Gamma irradiation testing of prototype ITER in-vessel magnetic pick-up coils

    International Nuclear Information System (INIS)

    Vermeeren, Ludo; Leysen, Willem

    2013-01-01

    Highlights: ► We tested five prototype ITER in-vessel coils up to a gamma dose of 72 MGy. ► Before and after irradiation thermal tests were also performed from 30 °C till 130 °C. ► The continuity resistances and the insulation resistances were continuously monitored. ► The observed behavior of all coils was satisfactory in all conditions. ► For the further design the mechanical robustness should be taken into account. -- Abstract: To fulfill the requirements for ITER in-vessel magnetic diagnostics, several coil prototypes have been developed, aiming at minimizing the disturbing effects of temperature gradients and radiation induced phenomena. As a first step in the radiation resistance testing of these prototypes, an in-situ high dose rate gamma radiation test on a selection of prototypes was performed. The aim of this test was to get a first experimental feedback regarding the behavior of the pick-up coil prototypes under radiation. Five prototypes (a coil wound with glass-insulated copper wire, two LTCC coils and two HTCC coils) were irradiated at a dose rate of 46 kGy/h up to a total dose of 72 MGy and at a temperature of 50 °C. During the irradiation, the continuity resistances and the insulation resistances were continuously measured. Before and after irradiation reference data were recorded as a function of temperature (from 30 °C to 130 °C). This paper includes the results of the temperature and irradiation tests and a discussion of the behavior of the prototype coils in terms of electrical and mechanical properties

  10. Calibration of an air monitor prototype for a radiation surveillance network based on gamma spectrometry

    International Nuclear Information System (INIS)

    Baeza, A.; Caballero, J.M.; Corbacho, J.Á.; Ontalba-Salamanca, M.Á.; Vasco, J.

    2014-01-01

    The objective of this work is to present the improvements that have been made in quasi-real-time air radioactivity concentration monitors which were initially based on overall activity determinations, by incorporating gamma spectrometry into the current prototype. To this end it was necessary to develop a careful efficiency calibration procedure for both the particulate and the gaseous fractions of the air being sampled. The work also reports the values of the minimum detectable activity calculated for different isotopes and acquisition times. - Highlights: • Deficiencies of a commercial air monitoring system are detailed. • Gamma spectrometry introduction is the basis of the new prototype. • Efficiency calibration procedure is described for aerosol and gaseous fractions. • MDA is evaluated for different isotopes and acquisition times

  11. Digital and Analog Electronics for an autonomous, deep-sea, Gamma Ray Burst Neutrino prototype detector

    Directory of Open Access Journals (Sweden)

    Manolopoulos K.

    2016-01-01

    Full Text Available GRBNeT is a Gamma Ray Burst Neutrino Telescope made of autonomously operated arrays of deep-sea light detectors, anchored to the sea-bed without any cabled connection to the shore. This paper presents the digital and analog electronics that we have designed and developed for the GRBNeT prototype. We describe the requirements for these electronics and present their design and functionality. We present low-power analog electronics for the PMTs utilized in the GRBNeT prototype and the FPGA based digital system for data selection and storage. We conclude with preliminary performance measurements of the electronics systems for the GRBNeT prototype.

  12. Development of a prototype gamma camera (Aladin) for use in decommissioning nuclear facilities

    International Nuclear Information System (INIS)

    Imbard, G.; Carcreff, H.

    1995-01-01

    Mapping the gamma activity of irradiating zones is often an important prerequisite in dismantling nuclear facilities. This operation is necessary to define a suitable decommissioning strategy before any work begins; it is also required during the procedure to measure the residual activity wherever dose rates are too high to allow human intervention. This paper summarizes the work carried out develop a prototype imaging system designed to display radioactive sources superimposed in real time over a visible light image on a video monitor. This project was developed from an earlier off-line system. (authors). 8 refs., 7 figs., 3 tabs

  13. SiPM-MAROC gamma-camera prototype with monolithic NaI(Tl) scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Philippov, Dmitry; Ilyin, Andrey; Belyaev, Vladimir; Popova, Elan [National Research Nuclear University, Moscow Engineering Physics Institute (Russian Federation); Buzhan, Pavel; Stifutkin, Alexei [Moscow Engineering Physics Institute (Russian Federation)

    2015-05-18

    A full-body gamma-camera based on SiPM readout is currently under development as a part of MEPHI R activity supported in the framework of Russian Megagrants program. A goal of this development is a fast upgrade of existing medical equipment with minor changes in a system design and construction in order to combine SPECT and MR instruments. A monolithic NaI(Tl) scintillator commonly used for conventional PMT-based gamma cameras has been chosen for this study. SiPMs will be coupled with the scintillator via an optical guide. To cover scintillator surface thousands of SiPMs are required, together with multichannel front-end electronics. That means that readout electronics have to be very compact, with low power consumption and low cost. 64 – channel ASIC MAROC from Weeroc provides individual readout of each SiPM and has been considered as the best choice among electronics solutions available on the market. As the photodetector parameters are the key issues here, KETEK SiPMs with high detection efficiency, low crosstalk and low noise have been chosen for this study. In order to study the proposed detection system in detail and obtain detector module parameters, required for MC simulation, a 64-channel small prototype with 6x6mm{sup 2} SiPMs has been constructed and tested. SiPMs in SMD packages have been assembled as a matrix of 8x8 elements and readout by MAROC-based board. Prototype has been tested with different shape NaI(Tl) scintillators and gammas with different energy. Dedicated algorithms for extraction of gamma-event’s energy and position are under development. They are based on fitting a matrix of individual SiPMs responses by an analytical function F(x,y). They will be tested with GEANT-simulated events and experimental data. Development of the next (engineering) prototype of SiPM’s module for gamma-camera will be started soon.

  14. SiPM-MAROC gamma-camera prototype with monolithic NaI(Tl) scintillator

    International Nuclear Information System (INIS)

    Philippov, Dmitry; Ilyin, Andrey; Belyaev, Vladimir; Popova, Elan; Buzhan, Pavel; Stifutkin, Alexei

    2015-01-01

    A full-body gamma-camera based on SiPM readout is currently under development as a part of MEPHI R activity supported in the framework of Russian Megagrants program. A goal of this development is a fast upgrade of existing medical equipment with minor changes in a system design and construction in order to combine SPECT and MR instruments. A monolithic NaI(Tl) scintillator commonly used for conventional PMT-based gamma cameras has been chosen for this study. SiPMs will be coupled with the scintillator via an optical guide. To cover scintillator surface thousands of SiPMs are required, together with multichannel front-end electronics. That means that readout electronics have to be very compact, with low power consumption and low cost. 64 – channel ASIC MAROC from Weeroc provides individual readout of each SiPM and has been considered as the best choice among electronics solutions available on the market. As the photodetector parameters are the key issues here, KETEK SiPMs with high detection efficiency, low crosstalk and low noise have been chosen for this study. In order to study the proposed detection system in detail and obtain detector module parameters, required for MC simulation, a 64-channel small prototype with 6x6mm 2 SiPMs has been constructed and tested. SiPMs in SMD packages have been assembled as a matrix of 8x8 elements and readout by MAROC-based board. Prototype has been tested with different shape NaI(Tl) scintillators and gammas with different energy. Dedicated algorithms for extraction of gamma-event’s energy and position are under development. They are based on fitting a matrix of individual SiPMs responses by an analytical function F(x,y). They will be tested with GEANT-simulated events and experimental data. Development of the next (engineering) prototype of SiPM’s module for gamma-camera will be started soon.

  15. Handheld juggernaut.

    Science.gov (United States)

    Hagland, Mark

    2010-08-01

    Not only are hospital, health system, and medical group ClOs and clinical informaticists deploying handheld mobile devices across their enterprises as clinical computing tools; clinicians, especially physicians, are increasingly bringing their own BlackBerrys, iPhones, iPads, Android devices, and other handhelds, into patient care organizations for their personal clinical use. Not surprisingly, the challenges--as well as the opportunities--are multilayered and complex, and include the strategic planning, infrastructure, clinician preference, clinician workflow, and security issues involved in the emerging mobile handheld revolution. The diversity of approaches among ClOs and other healthcare IT leaders on such issues is striking, and underscores the need for flexibility and nimbleness going forward.

  16. Handheld Microfluidic Blood Ananlyzer, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Nanohmics proposes to develop a handheld blood analyzer for micro- and hypo-gravity missions. The prototype instrument will combine impedance analysis with optical...

  17. A prototype small CdTe gamma camera for radioguided surgery and other imaging applications.

    Science.gov (United States)

    Tsuchimochi, Makoto; Sakahara, Harumi; Hayama, Kazuhide; Funaki, Minoru; Ohno, Ryoichi; Shirahata, Takashi; Orskaug, Terje; Maehlum, Gunnar; Yoshioka, Koki; Nygard, Einar

    2003-12-01

    Gamma probes have been used for sentinel lymph node biopsy in melanoma and breast cancer. However, these probes can provide only radioactivity counts and variable pitch audio output based on the intensity of the detected radioactivity. We have developed a small semiconductor gamma camera (SSGC) that allows visualisation of the size, shape and location of the target tissues. This study is designed to characterise the performance of the SSGC for radioguided surgery of metastatic lesions and for other imaging applications amenable to the smaller format of this prototype imaging system. The detector head had 32 cadmium telluride semiconductor arrays with a total of 1,024 pixels, and with application-specific integrated circuits (ASICs) and a tungsten collimator. The entire assembly was encased in a lead housing measuring 152 mmx166 mmx65 mm. The effective visual field was 44.8 mmx44.8 mm. The energy resolution and imaging aspects were tested. Two spherical 5-mm- and 15-mm-diameter technetium-99m radioactive sources that had activities of 0.15 MBq and 100 MBq, respectively, were used to simulate a sentinel lymph node and an injection site. The relative detectability of these foci by the new detector and a conventional scintillation camera was studied. The prototype was also examined in a variety of clinical applications. Energy resolution [full-width at half-maximum (FWHM)] for a single element at the centre of the field of view was 4.2% at 140 keV (99mTc), and the mean energy resolution of the CdTe detector arrays was approximately 7.8%. The spatial resolution, represented by FWHM, had a mean value of 1.56 +/- 0.05 mm. Simulated node foci could be visualised clearly by the SSGC using a 15-s acquisition time. In preliminary clinical tests, the SSGC successfully imaged diseases in a variety of tissues, including salivary and thyroid glands, temporomandibular joints and sentinel lymph nodes. The SSGC has significant potential for diagnosing diseases and facilitating

  18. A prototype small CdTe gamma camera for radioguided surgery and other imaging applications

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchimochi, Makoto; Hayama, Kazuhide [Department of Oral and Maxillofacial Radiology, The Nippon Dental University School of Dentistry at Niigata, 1-8 Hamaura-cho, 951-8580, Niigata (Japan); Sakahara, Harumi [Department of Radiology, Hamamatsu University School of Medicine, Hamamatsu (Japan); Funaki, Minoru; Ohno, Ryoichi; Shirahata, Takashi [Acrorad Co. Ltd., Tokyo (Japan); Orskaug, Terje; Maehlum, Gunnar; Yoshioka, Koki; Nygard, Einar [Integrated Detector and Electronics A.S (IDE AS), Hovik (Norway)

    2003-12-01

    Gamma probes have been used for sentinel lymph node biopsy in melanoma and breast cancer. However, these probes can provide only radioactivity counts and variable pitch audio output based on the intensity of the detected radioactivity. We have developed a small semiconductor gamma camera (SSGC) that allows visualisation of the size, shape and location of the target tissues. This study is designed to characterise the performance of the SSGC for radioguided surgery of metastatic lesions and for other imaging applications amenable to the smaller format of this prototype imaging system. The detector head had 32 cadmium telluride semiconductor arrays with a total of 1,024 pixels, and with application-specific integrated circuits (ASICs) and a tungsten collimator. The entire assembly was encased in a lead housing measuring 152 mm x 166 mm x 65 mm. The effective visual field was 44.8 mm x 44.8 mm. The energy resolution and imaging aspects were tested. Two spherical 5-mm- and 15-mm-diameter technetium-99m radioactive sources that had activities of 0.15 MBq and 100 MBq, respectively, were used to simulate a sentinel lymph node and an injection site. The relative detectability of these foci by the new detector and a conventional scintillation camera was studied. The prototype was also examined in a variety of clinical applications. Energy resolution [full-width at half-maximum (FWHM)] for a single element at the centre of the field of view was 4.2% at 140 keV ({sup 99m}Tc), and the mean energy resolution of the CdTe detector arrays was approximately 7.8%. The spatial resolution, represented by FWHM, had a mean value of 1.56{+-}0.05 mm. Simulated node foci could be visualised clearly by the SSGC using a 15-s acquisition time. In preliminary clinical tests, the SSGC successfully imaged diseases in a variety of tissues, including salivary and thyroid glands, temporomandibular joints and sentinel lymph nodes. The SSGC has significant potential for diagnosing diseases and

  19. A prototype small CdTe gamma camera for radioguided surgery and other imaging applications

    International Nuclear Information System (INIS)

    Tsuchimochi, Makoto; Hayama, Kazuhide; Sakahara, Harumi; Funaki, Minoru; Ohno, Ryoichi; Shirahata, Takashi; Orskaug, Terje; Maehlum, Gunnar; Yoshioka, Koki; Nygard, Einar

    2003-01-01

    Gamma probes have been used for sentinel lymph node biopsy in melanoma and breast cancer. However, these probes can provide only radioactivity counts and variable pitch audio output based on the intensity of the detected radioactivity. We have developed a small semiconductor gamma camera (SSGC) that allows visualisation of the size, shape and location of the target tissues. This study is designed to characterise the performance of the SSGC for radioguided surgery of metastatic lesions and for other imaging applications amenable to the smaller format of this prototype imaging system. The detector head had 32 cadmium telluride semiconductor arrays with a total of 1,024 pixels, and with application-specific integrated circuits (ASICs) and a tungsten collimator. The entire assembly was encased in a lead housing measuring 152 mm x 166 mm x 65 mm. The effective visual field was 44.8 mm x 44.8 mm. The energy resolution and imaging aspects were tested. Two spherical 5-mm- and 15-mm-diameter technetium-99m radioactive sources that had activities of 0.15 MBq and 100 MBq, respectively, were used to simulate a sentinel lymph node and an injection site. The relative detectability of these foci by the new detector and a conventional scintillation camera was studied. The prototype was also examined in a variety of clinical applications. Energy resolution [full-width at half-maximum (FWHM)] for a single element at the centre of the field of view was 4.2% at 140 keV ( 99m Tc), and the mean energy resolution of the CdTe detector arrays was approximately 7.8%. The spatial resolution, represented by FWHM, had a mean value of 1.56±0.05 mm. Simulated node foci could be visualised clearly by the SSGC using a 15-s acquisition time. In preliminary clinical tests, the SSGC successfully imaged diseases in a variety of tissues, including salivary and thyroid glands, temporomandibular joints and sentinel lymph nodes. The SSGC has significant potential for diagnosing diseases and facilitating

  20. Gamma-ray and neutron area monitoring system of linear IFMIF prototype accelerator building

    International Nuclear Information System (INIS)

    Takahashi, Hiroki; Kojima, Toshiyuki; Narita, Takahiro; Tsutsumi, Kazuyoshi; Maebara, Sunao; Sakaki, Hironao; Nishiyama, Koichi

    2013-01-01

    Highlights: • Area monitoring system and control system are needed for LIPAc radiation management. • To secure the radiation safety, these systems are linked with two kinds of data path. • Hardwired data paths are adopted to realize the fast transfer of interlock signals. • Dual LAN and shared memory are adopted to the reliable transfer of monitoring data. • Data transfers without unnecessary load are designed and configured for these systems. -- Abstract: The linear IFMIF prototype accelerator (LIPAc) produces deuteron beam with 1 MW power. Since huge number of neutrons occur from such a high power beam, therefore, it is important for the radiation management to design a high reliability area monitoring system for gamma-rays and neutrons. To obtain the valuable operation data of the high-power deuteron beam at LIPAc, it is important to link and record the beam operation data and the area monitoring data. We realize the reliable data transfer to provide the area monitoring data to the accelerator control system which needs a high reliability using the shared-memory data link method. This paper describes the area monitoring system in the LIPAc building and the data-link between this system and the LIPAc control system

  1. PET-Probe: Evaluation of Technical Performance and Clinical Utility of a Handheld High-Energy Gamma Probe in Oncologic Surgery.

    Science.gov (United States)

    Gulec, Seza A; Daghighian, Farhad; Essner, Richard

    2016-12-01

    Positron emission tomography (PET) has become an invaluable part of patient evaluation in surgical oncology. PET is less than optimal for detecting lesions PET-positive lesions can be challenging as a result of difficulties in surgical exposure. We undertook this investigation to assess the utility of a handheld high-energy gamma probe (PET-Probe) for intraoperative identification of 18 F-deoxyglucose (FDG)-avid tumors. Forty patients underwent a diagnostic whole-body FDG-PET scan for consideration for surgical exploration and resection. Before surgery, all patients received an intravenous injection of 7 to 10 mCi of FDG. At surgery, the PET-Probe was used to determine absolute counts per second at the known tumor site(s) demonstrated by whole-body PET and at adjacent normal tissue (at least 4 cm away from tumor-bearing sites). Tumor-to-background ratios were calculated. Thirty-two patients (80%) underwent PET-Probe-guided surgery with therapeutic intent in a recurrent or metastatic disease setting. Eight patients underwent surgery for diagnostic exploration. Anatomical locations of the PET-identified lesions were neck and supraclavicular (n = 8), axilla (n = 5), groin and deep iliac (n = 4), trunk and extremity soft tissue (n = 3), abdominal and retroperitoneal (n = 19), and lung (n = 2). PET-Probe detected all PET-positive lesions. The PET-Probe was instrumental in localization of lesions in 15 patients that were not immediately apparent by surgical exploration. The PET-Probe identified all lesions demonstrated by PET scanning and, in selected cases, was useful in localizing FDG-avid disease not seen with conventional PET scanning.

  2. Ground tests with prototype of CeBr{sub 3} active gamma ray spectrometer proposed for future venus surface missions

    Energy Technology Data Exchange (ETDEWEB)

    Litvak, M.L., E-mail: litvak@mx.iki.rssi.ru [Space Research Institute, RAS, Moscow 117997 (Russian Federation); Sanin, A.B.; Golovin, D.V. [Space Research Institute, RAS, Moscow 117997 (Russian Federation); Jun, I. [Jet Propulsion Laboratory, Pasadena, CA (United States); Mitrofanov, I.G. [Space Research Institute, RAS, Moscow 117997 (Russian Federation); Shvetsov, V.N.; Timoshenko, G.N. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Vostrukhin, A.A. [Space Research Institute, RAS, Moscow 117997 (Russian Federation)

    2017-03-11

    The results of a series of ground tests with a prototype of an active gamma-ray spectrometer based on a new generation of scintillation crystal (CeBr{sub 3}) are presented together with a consideration to its applicability to future Venus landing missions. We evaluated the instrument's capability to distinguish the subsurface elemental composition of primary rock forming elements such as O, Na, Mg, Al, Si, K and Fe. Our study uses heritage from previous ground and field tests and applies to the analysis of gamma lines from activation reaction products generated by a pulsed neutron generator. We have estimated that the expected accuracies achieved in this approach could be as high as 1–10% for the particular chemical element being studied.

  3. An Intelligent Hand-Held Microsurgical Instrument for Improved Accuracy

    National Research Council Canada - National Science Library

    Ang, Wei

    2001-01-01

    This paper presents the development and initial experimental results of the first prototype of Micron, an active hand-held instrument to sense and compensate physiological tremor and other unwanted...

  4. Development and validation of a thermodynamic model for the performance analysis of a gamma Stirling engine prototype

    International Nuclear Information System (INIS)

    Araoz, Joseph A.; Cardozo, Evelyn; Salomon, Marianne; Alejo, Lucio; Fransson, Torsten H.

    2015-01-01

    This work presents the development and validation of a numerical model that represents the performance of a gamma Stirling engine prototype. The model follows a modular approach considering ideal adiabatic working spaces; limited internal and external heat transfer through the heat exchangers; and mechanical and thermal losses during the cycle. In addition, it includes the calculation of the mechanical efficiency taking into account the crank mechanism effectiveness and the forced work during the cycle. Consequently, the model aims to predict the work that can be effectively taken from the shaft. The model was compared with experimental data obtained in an experimental rig built for the engine prototype. The results showed an acceptable degree of accuracy when comparing with the experimental data, with errors ranging from ±1% to ±8% for the temperature in the heater side, less than ±1% error for the cooler temperatures, and ±1 to ±8% for the brake power calculations. Therefore, the model was probed adequate for study of the prototype performance. In addition, the results of the simulation reflected the limited performance obtained during the prototype experiments, and a first analysis of the results attributed this to the forced work during the cycle. The implemented model is the basis for a subsequent parametric analysis that will complement the results presented. - Highlights: • A numerical model for a Stirling engine was developed. • A mechanical efficiency analysis was included in the model. • The model was validated with experimental data of a novel prototype. • The model results permit a deeper insight into the engine operation

  5. A prototype of radioactive waste drum monitor by non-destructive assays using gamma spectrometry

    International Nuclear Information System (INIS)

    Thanh, Tran Thien; Trang, Hoang Thi Kieu; Chuong, Huynh Dinh; Nguyen, Vo Hoang; Tran, Le Bao; Tam, Hoang Duc; Tao, Chau Van

    2016-01-01

    In this work, segmented gamma scanning and the gamma emission tomography were used to locate unknown sources in a radioactive waste drum. The simulated detector response function and full energy peak efficiency are compared to corresponding experimental data and show about 5.3% difference for an energy ranging from 81 keV to 1332.5 keV for point sources. Computation of the corresponding activity is in good agreement with the true values. - Highlights: • Segmented gamma scanning and gamma emission tomography are used to locate point source in waste drums. • The PENELOPE software is used to compute the detection efficiency of the localized point source in the waste drum. • The activity of "1"3"7Cs and "6"0Co point source could be determined with an accuracy better than 10% for air and sand matrices.

  6. Development of a prototype apparatus visualizing on a screen the gamma sources superimposed on the image of the vision field

    Energy Technology Data Exchange (ETDEWEB)

    Imbard, G.; Lemaire, J.E. [CEA Centre d`Etudes de la Vallee du Rhone, 30 - Marcoule (France). Dept. d`Exploitation du Retraitement et de Demantelement; Carcreff, H.; Marchand, L.; Thellier, G. [CEA Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. des Reacteurs Experimentaux

    1994-12-31

    Mapping the gamma activity of irradiating zones is often an important prerequisite in dismantling nuclear facilities. The operation is necessary to define a suitable decommissioning strategy before any work begins; it is also required during the procedure to measure the residual activity wherever dose rates are too high to allow human intervention. This report summarizes the work carried out under CEC contract FIED-0055, covering a prototype imaging system designed to display radioactive sources superimposed in real time over a visible light image on a video monitor. This project was developed from an earlier off-line system. The gamma photons are collimated by a double cone system. The imaging system comprises a transparent scintillator bonded to the fiber-optic window of an ultrasensitive camera. The camera was miniaturized to meet specification requirements: with its radiological shielding, the gamma camera weighs 40 kg and is 120 mm in diameter. The processing system is compatible with a realtime camera, and small enough for use at any nuclear. The point-source angular resolution is 1.4 deg. for {sup 60} Co and 0.8 deg. for {sup 137} Cs. The dose rate sensitivity limit is approximately 0.01 mGy.h{sup -1}. Process reliability was confirmed by tests in a high-level radio-metallurgy cell at actual decommissioning site. (authors). 7 figs.

  7. Operating characteristics of a prototype high energy gamma-ray telescope

    International Nuclear Information System (INIS)

    Jenkins, T.L.; Frye, G.M.; Hall, C.J.; Owens, A.; Pendleton, G.N.; Carter, J.N.; Ramsden, D.; Agrinier, B.; Bonfand, E.; Refloch, A.; Tabary, A.

    1985-08-01

    We have operated a prototype coded aperture telescope in a tagged photon beam ranging in energy from 23 to 123 MeV. The purpose of the experiment was to demonstrate the feasibility of operating a coded aperture mask telescope in this energy region. This paper reports some preliminary results and conclusions drawn from some of the data resulting from this experiment

  8. Pyxis handheld polarimetric imager

    Science.gov (United States)

    Chenault, David B.; Pezzaniti, J. Larry; Vaden, Justin P.

    2016-05-01

    The instrumentation for measuring infrared polarization signatures has seen significant advancement over the last decade. Previous work has shown the value of polarimetric imagery for a variety of target detection scenarios including detection of manmade targets in clutter and detection of ground and maritime targets while recent work has shown improvements in contrast for aircraft detection and biometric markers. These data collection activities have generally used laboratory or prototype systems with limitations on the allowable amount of target motion or the sensor platform and usually require an attached computer for data acquisition and processing. Still, performance and sensitivity have been steadily getting better while size, weight, and power requirements have been getting smaller enabling polarimetric imaging for a greater or real world applications. In this paper, we describe Pyxis®, a microbolometer based imaging polarimeter that produces live polarimetric video of conventional, polarimetric, and fused image products. A polarization microgrid array integrated in the optical system captures all polarization states simultaneously and makes the system immune to motion artifacts of either the sensor or the scene. The system is battery operated, rugged, and weighs about a quarter pound, and can be helmet mounted or handheld. On board processing of polarization and fused image products enable the operator to see polarimetric signatures in real time. Both analog and digital outputs are possible with sensor control available through a tablet interface. A top level description of Pyxis® is given followed by performance characteristics and representative data.

  9. High resolution gamma-ray spectroscopy at high count rates with a prototype High Purity Germanium detector

    Science.gov (United States)

    Cooper, R. J.; Amman, M.; Vetter, K.

    2018-04-01

    High-resolution gamma-ray spectrometers are required for applications in nuclear safeguards, emergency response, and fundamental nuclear physics. To overcome one of the shortcomings of conventional High Purity Germanium (HPGe) detectors, we have developed a prototype device capable of achieving high event throughput and high energy resolution at very high count rates. This device, the design of which we have previously reported on, features a planar HPGe crystal with a reduced-capacitance strip electrode geometry. This design is intended to provide good energy resolution at the short shaping or digital filter times that are required for high rate operation and which are enabled by the fast charge collection afforded by the planar geometry crystal. In this work, we report on the initial performance of the system at count rates up to and including two million counts per second.

  10. A Fieldable-Prototype Large-Area Gamma-ray Imager for Orphan Source Search

    Energy Technology Data Exchange (ETDEWEB)

    Ziock, Klaus-Peter [ORNL; Fabris, Lorenzo [ORNL; Carr, Dennis [Lawrence Livermore National Laboratory (LLNL); Collins, Jeff [Lawrence Livermore National Laboratory (LLNL); Cunningham, Mark F [Lawrence Livermore National Laboratory (LLNL); Habte Ghebretatios, Frezghi [ORNL; Karnowski, Thomas Paul [ORNL; Marchant, William [University of California, Berkeley

    2008-01-01

    We have constructed a unique instrument for use in the search for orphan sources. The system uses gamma-ray imaging to "see through" the natural background variations that effectively limit the search range of normal devices to ~10 m. The imager is mounted in a 4.9- m-long trailer and can be towed by a large personal vehicle. Source locations are determined both in range and along the direction of travel as the vehicle moves. A fully inertial platform coupled to a Global Positioning System receiver is used to map the gamma-ray images onto overhead geospatial imagery. The resulting images provide precise source locations, allowing rapid follow-up work. The instrument simultaneously searches both sides of the street to a distance of 50 m (100-m swath) for milliCurieclass sources with near-perfect performance.

  11. Design and operation of a prototype incinerator for beta-gamma waste

    International Nuclear Information System (INIS)

    Farber, M.G.; Hootman, H.E.; Becker, G.W. Jr.; Makohon, P.A.

    1981-01-01

    A full-scale test incinerator has been built at the Savannah River Laboratory to provide a design basis for a radioactive facility that will burn low-level beta-gamma contaminated waste. The processing steps include waste feed loading, incineration, ash residue packaging, and off-gas cleanup. Both solid and liquid waste will be incinerated during the test program. The components of the solid waste are cellulose, latex, polyethylene, and PVC; the solvent is composed of n-paraffin and TBP. A research program will confirm the feasibility of the design and determine the operating parameters

  12. Combined approach of perioperative 18F-FDG PET/CT imaging and intraoperative 18F-FDG handheld gamma probe detection for tumor localization and verification of complete tumor resection in breast cancer

    Directory of Open Access Journals (Sweden)

    Knopp Michael V

    2007-12-01

    Full Text Available Abstract Background 18F-fluorodeoxyglucose (18F-FDG positron emission tomography/computed tomography (PET/CT has become an established method for detecting hypermetabolic sites of known and occult disease and is widely used in oncology surgical planning. Intraoperatively, it is often difficult to localize tumors and verify complete resection of tumors that have been previously detected on diagnostic PET/CT at the time of the original evaluation of the cancer patient. Therefore, we propose an innovative approach for intraoperative tumor localization and verification of complete tumor resection utilizing 18F-FDG for perioperative PET/CT imaging and intraoperative gamma probe detection. Methods Two breast cancer patients were evaluated. 18F-FDG was administered and PET/CT was acquired immediately prior to surgery. Intraoperatively, tumors were localized and resected with the assistance of a handheld gamma probe. Resected tumors were scanned with specimen PET/CT prior to pathologic processing. Shortly after the surgical procedure, patients were re-imaged with PET/CT utilizing the same preoperatively administered 18F-FDG dose. Results One patient had primary carcinoma of breast and a metastatic axillary lymph node. The second patient had a solitary metastatic liver lesion. In both cases, preoperative PET/CT verified these findings and demonstrated no additional suspicious hypermetabolic lesions. Furthermore, intraoperative gamma probe detection, specimen PET/CT, and postoperative PET/CT verified complete resection of the hypermetabolic lesions. Conclusion Immediate preoperative and postoperative PET/CT imaging, utilizing the same 18F-FDG injection dose, is feasible and image quality is acceptable. Such perioperative PET/CT imaging, along with intraoperative gamma probe detection and specimen PET/CT, can be used to verify complete tumor resection. This innovative approach demonstrates promise for assisting the oncologic surgeon in localizing and

  13. Experimental evaluation of an online gamma-camera imaging of permanent seed implantation (OGIPSI) prototype for partial breast irradiation

    International Nuclear Information System (INIS)

    Ravi, Ananth; Caldwell, Curtis B.; Pignol, Jean-Philippe

    2008-01-01

    Previously, our team used Monte Carlo simulation to demonstrate that a gamma camera could potentially be used as an online image guidance device to visualize seeds during permanent breast seed implant procedures. This could allow for intraoperative correction if seeds have been misplaced. The objective of this study is to describe an experimental evaluation of an online gamma-camera imaging of permanent seed implantation (OGIPSI) prototype. The OGIPSI device is intended to be able to detect a seed misplacement of 5 mm or more within an imaging time of 2 min or less. The device was constructed by fitting a custom built brass collimator (16 mm height, 0.65 mm hole pitch, 0.15 mm septal thickness) on a 64 pixel linear array CZT detector (eValuator-2000, eV Products, Saxonburg, PA). Two-dimensional projection images of seed distributions were acquired by the use of a digitally controlled translation stage. Spatial resolution and noise characteristics of the detector were measured. The ability and time needed for the OGIPSI device to image the seeds and to detect cold spots was tested using an anthropomorphic breast phantom. Mimicking a real treatment plan, a total of 52 103 Pd seeds of 65.8 MBq each were placed on three different layers at appropriate depths within the phantom. The seeds were reliably detected within 30 s with a median error in localization of 1 mm. In conclusion, an OGIPSI device can potentially be used for image guidance of permanent brachytherapy applications in the breast and, possibly, other sites

  14. ITSY Handheld Software Radio

    National Research Council Canada - National Science Library

    Bose, Vanu

    2001-01-01

    .... A handheld software radio platform would enable the construction of devices that could inter-operate with multiple legacy systems, download new waveforms and be used to construct adhoc networks...

  15. Tests of the space gamma spectrometer prototype at the JINR experimental facility with different types of neutron generators

    Science.gov (United States)

    Litvak, M. L.; Vostrukhin, A. A.; Golovin, D. V.; Dubasov, P. V.; Zontikov, A. O.; Kozyrev, A. S.; Krylov, A. R.; Krylov, V. A.; Mitrofanov, I. G.; Mokrousov, M. I.; Repkin, A. N.; Timoshenko, G. N.; Udovichenko, K. V.; Shvetsov, V. N.

    2017-07-01

    The results of the tests of the HPGe gamma spectrometer performed with a planetary soil model and different types of pulse neutron generators are presented. All measurements have been performed at the experimental nuclear planetary science facility (Joint Institute for Nuclear Research) for the physical calibration of active gamma and neutron spectrometers. The aim of the study is to model a space experiment on determining the elemental composition of Martian planetary matter by neutron-induced gamma spectroscopy. The advantages and disadvantages of a gas-filled neutron generator in comparison with a vacuum-tube neutron generator are examined.

  16. Possibility of observation by the Antares telescope of the gamma ray point sources observed by the Egret detector and study of a prototype

    International Nuclear Information System (INIS)

    Saouter, S.

    2004-09-01

    The ANTARES collaboration aims to install an underwater neutrino telescope at 2 500 m deep and 40 km away from Toulon (France). The neutrinos are detected thanks to their interaction by charged current in the medium surrounding the telescope which can be rock or water. The produced muon emits Tcherenkov light along its path in water. This light is detected by a three-dimensional network of 900 photomultipliers divided into 12 independent lines. To validate the chosen techniques, a prototype made up of a fifth of line was deployed in 2003. A reconstruction algorithm was developed on simulated data whose results are presented. However, a technical failure made the data recorded by the prototype unsuitable. The detection potential of Antares to gamma ray sources observed by Egret is studied. Indeed, under the assumption of a gamma ray production via high-energy hadrons, a comparable flux of neutrinos associated is predicted. By supposing the two fluxes equal and an energy spectrum varying as E -2 eleven sources are potentially detectable in one year. The Antares sensitivity to such a spectrum depends on the declination of the source with an optimum of 3.6 10 -4 m -2 s -1 GeV -1 in one year at 90% of confidence level for a declination of - 90 deg C. (author)

  17. Performance of the prototype LaBr{sub 3} spectrometer developed for the JET gamma-ray camera upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Rigamonti, D., E-mail: davide.rigamonti@mib.infn.it; Nocente, M.; Gorini, G. [Dipartimento di Fisica “G. Occhialini,” Università degli Studi di Milano-Bicocca, Milano (Italy); Istituto di Fisica del Plasma “P. Caldirola,” CNR, Milano (Italy); Muraro, A.; Giacomelli, L.; Cippo, E. P.; Tardocchi, M. [Istituto di Fisica del Plasma “P. Caldirola,” CNR, Milano (Italy); Perseo, V. [Dipartimento di Fisica “G. Occhialini,” Università degli Studi di Milano-Bicocca, Milano (Italy); Boltruczyk, G.; Gosk, M.; Korolczuk, S.; Mianowski, S.; Zychor, I. [Narodowe Centrum Badań Jądrowych (NCBJ), 05-400 Otwock-Swierk (Poland); Fernandes, A.; Pereira, R. C. [Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, Lisboa (Portugal); Figueiredo, J. [Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, Lisboa (Portugal); EUROfusion Programme Management Unit, Culham Science Centre, OX14 3DB Abingdon (United Kingdom); Kiptily, V. [Culham Science Centre for Fusion Energy, Culham (United Kingdom); Murari, A. [EUROfusion Programme Management Unit, Culham Science Centre, OX14 3DB Abingdon (United Kingdom); Consorzio RFX (CNR, ENEA, INFN, Universita’ di Padova, Acciaierie Venete SpA), Padova (Italy); Collaboration: EUROfusion Consortium, JET, Culham Science Centre, Abingdon OX14 3DB (United Kingdom)

    2016-11-15

    In this work, we describe the solution developed by the gamma ray camera upgrade enhancement project to improve the spectroscopic properties of the existing JET γ-ray camera. Aim of the project is to enable gamma-ray spectroscopy in JET deuterium-tritium plasmas. A dedicated pilot spectrometer based on a LaBr{sub 3} crystal coupled to a silicon photo-multiplier has been developed. A proper pole zero cancellation network able to shorten the output signal to a length of 120 ns has been implemented allowing for spectroscopy at MHz count rates. The system has been characterized in the laboratory and shows an energy resolution of 5.5% at E{sub γ} = 0.662 MeV, which extrapolates favorably in the energy range of interest for gamma-ray emission from fast ions in fusion plasmas.

  18. Handheld Universal Diagnostic Sensor

    Science.gov (United States)

    Chan, Eugene

    2012-01-01

    The rHEALTH technology is designed to shrink an entire hospital testing laboratory onto a handheld device. A physician or healthcare provider performs the test by collecting a fingerstick of blood from a patient. The tiny volume of blood is inserted into the rHEALTH device. Inside the device is a microfluidic chip that contains small channels about the width of a human hair. These channels help move the blood and analyze the blood sample. The rHEALTH sensor uses proprietary reagents called nanostrips, which are nanoscale test strips that enable the clinical assays. The readout is performed by laser-induced fluorescence. Overall, the time from blood collection through analysis is less than a minute.

  19. Possibility of observation by the Antares telescope of the gamma ray point sources observed by the Egret detector and study of a prototype; Possibilite d'observation par le telescope Antares des sources ponctuelles de rayons gamma observees par le detecteur Egret et etude d'un prototype

    Energy Technology Data Exchange (ETDEWEB)

    Saouter, S

    2004-09-01

    The ANTARES collaboration aims to install an underwater neutrino telescope at 2 500 m deep and 40 km away from Toulon (France). The neutrinos are detected thanks to their interaction by charged current in the medium surrounding the telescope which can be rock or water. The produced muon emits Tcherenkov light along its path in water. This light is detected by a three-dimensional network of 900 photomultipliers divided into 12 independent lines. To validate the chosen techniques, a prototype made up of a fifth of line was deployed in 2003. A reconstruction algorithm was developed on simulated data whose results are presented. However, a technical failure made the data recorded by the prototype unsuitable. The detection potential of Antares to gamma ray sources observed by Egret is studied. Indeed, under the assumption of a gamma ray production via high-energy hadrons, a comparable flux of neutrinos associated is predicted. By supposing the two fluxes equal and an energy spectrum varying as E{sup -2} eleven sources are potentially detectable in one year. The Antares sensitivity to such a spectrum depends on the declination of the source with an optimum of 3.6 10{sup -4} m{sup -2} s{sup -1} GeV{sup -1} in one year at 90% of confidence level for a declination of - 90 deg C. (author)

  20. Possibility of observation by the Antares telescope of the gamma ray point sources observed by the Egret detector and study of a prototype; Possibilite d'observation par le telescope Antares des sources ponctuelles de rayons gamma observees par le detecteur Egret et etude d'un prototype

    Energy Technology Data Exchange (ETDEWEB)

    Saouter, S

    2004-09-01

    The ANTARES collaboration aims to install an underwater neutrino telescope at 2 500 m deep and 40 km away from Toulon (France). The neutrinos are detected thanks to their interaction by charged current in the medium surrounding the telescope which can be rock or water. The produced muon emits Tcherenkov light along its path in water. This light is detected by a three-dimensional network of 900 photomultipliers divided into 12 independent lines. To validate the chosen techniques, a prototype made up of a fifth of line was deployed in 2003. A reconstruction algorithm was developed on simulated data whose results are presented. However, a technical failure made the data recorded by the prototype unsuitable. The detection potential of Antares to gamma ray sources observed by Egret is studied. Indeed, under the assumption of a gamma ray production via high-energy hadrons, a comparable flux of neutrinos associated is predicted. By supposing the two fluxes equal and an energy spectrum varying as E{sup -2} eleven sources are potentially detectable in one year. The Antares sensitivity to such a spectrum depends on the declination of the source with an optimum of 3.6 10{sup -4} m{sup -2} s{sup -1} GeV{sup -1} in one year at 90% of confidence level for a declination of - 90 deg C. (author)

  1. Field Deployable Gamma Radiation Detectors for DHS Use

    Energy Technology Data Exchange (ETDEWEB)

    Sanjoy Mukhopadhyay

    2007-08-01

    Recently, the Department of Homeland Security (DHS) has integrated all nuclear detection research, development, testing, evaluation, acquisition, and operational support into a single office: the Domestic Nuclear Detection Office (DNDO). The DNDO has specific requirements set for all commercial off-the-shelf and government off-the-shelf radiation detection equipment and data acquisition systems. This article would investigate several recent developments in field deployable gamma radiation detectors that are attempting to meet the DNDO specifications. Commercially available, transportable, handheld radio isotope identification devices (RIID) are inadequate for DHS requirements in terms of sensitivity, resolution, response time, and reach-back capability. The leading commercial vendor manufacturing handheld gamma spectrometer in the United States is Thermo Electron Corporation. Thermo Electron's identiFINDER{trademark}, which primarily uses sodium iodide crystals (3.18 x 2.54cm cylinders) as gamma detectors, has a Full-Width-at-Half-Maximum energy resolution of 7 percent at 662 keV. Thermo Electron has just recently come up with a reach-back capability patented as RadReachBack{trademark} that enables emergency personnel to obtain real-time technical analysis of radiation samples they find in the field. The current project has the goal to build a prototype handheld gamma spectrometer, equipped with a digital camera and an embedded cell phone to be used as an RIID with higher sensitivity, better resolution, and faster response time (able to detect the presence of gamma-emitting radio isotopes within 5 seconds of approach), which will make it useful as a field deployable tool. The handheld equipment continuously monitors the ambient gamma radiation, and, if it comes across any radiation anomalies with higher than normal gamma gross counts, it sets an alarm condition. When a substantial alarm level is reached, the system automatically triggers the saving of relevant

  2. Field Deployable Gamma Radiation Detectors for DHS Use

    International Nuclear Information System (INIS)

    Sanjoy Mukhopadhyay

    2007-01-01

    Recently, the Department of Homeland Security (DHS) has integrated all nuclear detection research, development, testing, evaluation, acquisition, and operational support into a single office: the Domestic Nuclear Detection Office (DNDO). The DNDO has specific requirements set for all commercial off-the-shelf and government off-the-shelf radiation detection equipment and data acquisition systems. This article would investigate several recent developments in field deployable gamma radiation detectors that are attempting to meet the DNDO specifications. Commercially available, transportable, handheld radio isotope identification devices (RIID) are inadequate for DHS requirements in terms of sensitivity, resolution, response time, and reach-back capability. The leading commercial vendor manufacturing handheld gamma spectrometer in the United States is Thermo Electron Corporation. Thermo Electron's identiFINDER(trademark), which primarily uses sodium iodide crystals (3.18 x 2.54cm cylinders) as gamma detectors, has a Full-Width-at-Half-Maximum energy resolution of 7 percent at 662 keV. Thermo Electron has just recently come up with a reach-back capability patented as RadReachBack(trademark) that enables emergency personnel to obtain real-time technical analysis of radiation samples they find in the field. The current project has the goal to build a prototype handheld gamma spectrometer, equipped with a digital camera and an embedded cell phone to be used as an RIID with higher sensitivity, better resolution, and faster response time (able to detect the presence of gamma-emitting radio isotopes within 5 seconds of approach), which will make it useful as a field deployable tool. The handheld equipment continuously monitors the ambient gamma radiation, and, if it comes across any radiation anomalies with higher than normal gamma gross counts, it sets an alarm condition. When a substantial alarm level is reached, the system automatically triggers the saving of relevant

  3. Study of the background neutron and gamma components of the ββ(0ν) decay in the NEMO2 prototype detector. Consequences for the NEMO3 detector

    International Nuclear Information System (INIS)

    Marquet, Christine

    1999-01-01

    Neutrinoless double beta decay ββ(0ν) is a test of physics beyond the Standard Model by involving the existence of a massive Majorana neutrino (ν = ν-bar). To try to observe such a process with a sensitivity of 0.1 eV on the neutrino effective mass ( ν >), NEMO collaboration build the NEMO3 detector, able to measure half-lives greater than 10 24 years, corresponding to a few detected events per year. For that, it is necessary to know and master all background sources. This work was first dedicated to the study of external (to the double beta source) background with crossing electrons recorded with NEMO2 prototype detector and then to the simulation of this background in NEMO3 detector. Comparison between NEMO2 data and results of gamma and neutron simulations for different shieldings, with and without neutron source, has allowed to determine background contributions of radon, thoron, 208 Tl contaminations in materials, photon flux produced in laboratory and neutrons. This study, which has required improvements in the MICAP neutron simulation code by developing a photon generator, proved that radiative capture of fast neutrons thermalized in the detector was the source of events in the energy domain of the ββ(0ν) signal. In order to reach the required sensitivity on ν > mass, it has been shown that both a neutron shielding and magnetic field are necessary for NEMO3 detector. (author) [fr

  4. Digital forensics for handheld devices

    CERN Document Server

    Doherty, Eamon P

    2012-01-01

    Approximately 80 percent of the world's population now owns a cell phone, which can hold evidence or contain logs about communications concerning a crime. Cameras, PDAs, and GPS devices can also contain information related to corporate policy infractions and crimes. Aimed to prepare investigators in the public and private sectors, Digital Forensics for Handheld Devices examines both the theoretical and practical aspects of investigating handheld digital devices. This book touches on all areas of mobile device forensics, including topics from the legal, technical, academic, and social aspects o

  5. Architectural prototyping

    DEFF Research Database (Denmark)

    Bardram, Jakob Eyvind; Christensen, Henrik Bærbak; Hansen, Klaus Marius

    2004-01-01

    A major part of software architecture design is learning how specific architectural designs balance the concerns of stakeholders. We explore the notion of "architectural prototypes", correspondingly architectural prototyping, as a means of using executable prototypes to investigate stakeholders...

  6. Hand-held medical robots.

    Science.gov (United States)

    Payne, Christopher J; Yang, Guang-Zhong

    2014-08-01

    Medical robots have evolved from autonomous systems to tele-operated platforms and mechanically-grounded, cooperatively-controlled robots. Whilst these approaches have seen both commercial and clinical success, uptake of these robots remains moderate because of their high cost, large physical footprint and long setup times. More recently, researchers have moved toward developing hand-held robots that are completely ungrounded and manipulated by surgeons in free space, in a similar manner to how conventional instruments are handled. These devices provide specific functions that assist the surgeon in accomplishing tasks that are otherwise challenging with manual manipulation. Hand-held robots have the advantages of being compact and easily integrated into the normal surgical workflow since there is typically little or no setup time. Hand-held devices can also have a significantly reduced cost to healthcare providers as they do not necessitate the complex, multi degree-of-freedom linkages that grounded robots require. However, the development of such devices is faced with many technical challenges, including miniaturization, cost and sterility, control stability, inertial and gravity compensation and robust instrument tracking. This review presents the emerging technical trends in hand-held medical robots and future development opportunities for promoting their wider clinical uptake.

  7. Hand-held spectrophotometer design for textile fabrics

    Science.gov (United States)

    Böcekçi, Veysel Gökhan; Yıldız, Kazım

    2017-09-01

    In this study, a hand-held spectrophotometer was designed by taking advantage of the developments in modern optoelectronic technology. Spectrophotometer devices are used to determine the color information from the optic properties of the materials. As an alternative to a desktop spectrophotometer device we have implemented, it is the first prototype, low cost and portable. The prototype model designed for the textile industry can detect the color tone of any fabric. The prototype model consists of optic sensor, processor, display floors. According to the color applied on the optic sensor, it produces special frequency information on its output at that color value. In Arduino type processor, the frequency information is evaluated by the program we have written and the color tone information between 0-255 ton is decided and displayed on the screen.

  8. Prototype Demonstration of Gamma- Blind Tensioned Metastable Fluid Neutron/Multiplicity/Alpha Detector – Real Time Methods for Advanced Fuel Cycle Applications

    Energy Technology Data Exchange (ETDEWEB)

    McDeavitt, Sean M. [Texas A & M Univ., College Station, TX (United States)

    2016-12-20

    The content of this report summarizes a multi-year effort to develop prototype detection equipment using the Tensioned Metastable Fluid Detector (TMFD) technology developed by Taleyarkhan [1]. The context of this development effort was to create new methods for evaluating and developing advanced methods for safeguarding nuclear materials along with instrumentation in various stages of the fuel cycle, especially in material balance areas (MBAs) and during reprocessing of used nuclear fuel. One of the challenges related to the implementation of any type of MBA and/or reprocessing technology (e.g., PUREX or UREX) is the real-time quantification and control of the transuranic (TRU) isotopes as they move through the process. Monitoring of higher actinides from their neutron emission (including multiplicity) and alpha signatures during transit in MBAs and in aqueous separations is a critical research area. By providing on-line real-time materials accountability, diversion of the materials becomes much more difficult. The Tensioned Metastable Fluid Detector (TMFD) is a transformational technology that is uniquely capable of both alpha and neutron spectroscopy while being “blind” to the intense gamma field that typically accompanies used fuel – simultaneously with the ability to provide multiplicity information as well [1-3]. The TMFD technology was proven (lab-scale) as part of a 2008 NERI-C program [1-7]. The bulk of this report describes the advancements and demonstrations made in TMFD technology. One final point to present before turning to the TMFD demonstrations is the context for discussing real-time monitoring of SNM. It is useful to review the spectrum of isotopes generated within nuclear fuel during reactor operations. Used nuclear fuel (UNF) from a light water reactor (LWR) contains fission products as well as TRU elements formed through neutron absorption/decay chains. The majority of the fission products are gamma and beta emitters and they represent the

  9. Development of a novel gamma probe for detecting radiation direction

    Science.gov (United States)

    Pani, R.; Pellegrini, R.; Cinti, M. N.; Longo, M.; Donnarumma, R.; D'Alessio, A.; Borrazzo, C.; Pergola, A.; Ridolfi, S.; De Vincentis, G.

    2016-01-01

    Spatial localization of radioactive sources is currently a main issue interesting different fields, including nuclear industry, homeland security as well as medical imaging. It is currently achieved using different systems, but the development of technologies for detecting and characterizing radiation is becoming important especially in medical imaging. In this latter field, radiation detection probes have long been used to guide surgery, thanks to their ability to localize and quantify radiopharmaceutical uptake even deep in tissue. Radiolabelled colloid is injected into, or near to, the tumor and the surgeon uses a hand-held radiation detector, the gamma probe, to identify lymph nodes with radiopharmaceutical uptkake. The present work refers to a novel scintigraphic goniometric probe to identify gamma radiation and its direction. The probe incorporates several scintillation crystals joined together in a particular configuration to provide data related to the position of a gamma source. The main technical characteristics of the gamma locator prototype, i.e. sensitivity, spatial resolution and detection efficiency, are investigated. Moreover, the development of a specific procedure applied to the images permits to retrieve the source position with high precision with respect to the currently used gamma probes. The presented device shows a high sensitivity and efficiency to identify gamma radiation taking a short time (from 30 to 60 s). Even though it was designed for applications in radio-guided surgery, it could be used for other purposes, as for example homeland security.

  10. Development of a novel gamma probe for detecting radiation direction

    International Nuclear Information System (INIS)

    Pani, R.; Pellegrini, R.; Cinti, M.N.; Longo, M.; Donnarumma, R.; Borrazzo, C.; D'Alessio, A.; Pergola, A.; Ridolfi, S.; Vincentis, G. De

    2016-01-01

    Spatial localization of radioactive sources is currently a main issue interesting different fields, including nuclear industry, homeland security as well as medical imaging. It is currently achieved using different systems, but the development of technologies for detecting and characterizing radiation is becoming important especially in medical imaging. In this latter field, radiation detection probes have long been used to guide surgery, thanks to their ability to localize and quantify radiopharmaceutical uptake even deep in tissue. Radiolabelled colloid is injected into, or near to, the tumor and the surgeon uses a hand-held radiation detector, the gamma probe, to identify lymph nodes with radiopharmaceutical uptkake. The present work refers to a novel scintigraphic goniometric probe to identify gamma radiation and its direction. The probe incorporates several scintillation crystals joined together in a particular configuration to provide data related to the position of a gamma source. The main technical characteristics of the gamma locator prototype, i.e. sensitivity, spatial resolution and detection efficiency, are investigated. Moreover, the development of a specific procedure applied to the images permits to retrieve the source position with high precision with respect to the currently used gamma probes. The presented device shows a high sensitivity and efficiency to identify gamma radiation taking a short time (from 30 to 60 s). Even though it was designed for applications in radio-guided surgery, it could be used for other purposes, as for example homeland security

  11. Handheld Broadband Electromagnetic UXO Sensor

    National Research Council Canada - National Science Library

    Won, I. J; San Filipo, William A; Marqusee, Jeffrey; Andrews, Anne; Robitaille, George; Fairbanks, Jeffrey; Overbay, Larry

    2005-01-01

    The broadband electromagnetic sensor improvement and demonstration undertaken in this project took the prototype GEM-3 and evolved it into an operational sensor with increased bandwidth and dynamic...

  12. Collaborative Prototyping

    DEFF Research Database (Denmark)

    Bogers, Marcel; Horst, Willem

    2014-01-01

    of the prototyping process, the actual prototype was used as a tool for communication or development, thus serving as a platform for the cross-fertilization of knowledge. In this way, collaborative prototyping leads to a better balance between functionality and usability; it translates usability problems into design......This paper presents an inductive study that shows how collaborative prototyping across functional, hierarchical, and organizational boundaries can improve the overall prototyping process. Our combined action research and case study approach provides new insights into how collaborative prototyping...... can provide a platform for prototype-driven problem solving in early new product development (NPD). Our findings have important implications for how to facilitate multistakeholder collaboration in prototyping and problem solving, and more generally for how to organize collaborative and open innovation...

  13. Handheld ESPI-speckle interferometer

    DEFF Research Database (Denmark)

    Skov Hansen, René

    2003-01-01

    . The interferometer presented here is a compact version of the set-up, Which is capable of measuring displacements of small objects, having either a specularly reflecting-or a diffusely scattering surface. The small optical set-up together with the use of the popular USB-communication for acquiring the images...... and controlling the phase of the reference wave constitutes a compact "handheld" instrument and eliminates the need for installing extra hardware, such as frame grabber and Digital to Analog converter, in the host computer....

  14. Accentuated Factors of Handheld Computing

    DEFF Research Database (Denmark)

    Andersson, Bo; Henningsson, Stefan

    The recent years of rapid development of mobile technologies creates opportunities for new user-groups in the mobile workforce to take advantage of in-formation systems (IS). However, to apprehend and harness these opportunities for mobile IS it is crucial to fully understand the user group and t......, these two steps develop the framework towards a theoretical contribution as theory for describing handheld computing from a designer’s perspective. Thirteen semi-structured interviews were made and the tentative framework was elaborated and confirmed....

  15. Wireless Handhelds to Support Clinical Nursing Practicum

    Science.gov (United States)

    Wu, Cheng-Chih; Lai, Chin-Yuan

    2009-01-01

    This paper reports our implementation and evaluation of a wireless handheld learning environment used to support a clinical nursing practicum course. The learning environment was designed so that nursing students could use handhelds for recording information, organizing ideas, assessing patients, and also for interaction and collaboration with…

  16. A hand-held beta imaging probe for FDG.

    Science.gov (United States)

    Singh, Bipin; Stack, Brendan C; Thacker, Samta; Gaysinskiy, Valeriy; Bartel, Twyla; Lowe, Val; Cool, Steven; Entine, Gerald; Nagarkar, Vivek

    2013-04-01

    Advances in radiopharmaceuticals and clinical understanding have escalated the use of intraoperative gamma probes in surgery. However, most probes on the market are non-imaging gamma probes that suffer from the lack of ancillary information of the surveyed tissue area. We have developed a novel, hand-held digital Imaging Beta Probe™ (IBP™) to be used in surgery in conjunction with beta-emitting radiopharmaceuticals such as (18)FDG, (131)I and (32)P for real-time imaging of a surveyed area with higher spatial resolution and sensitivity and greater convenience than existing instruments. We describe the design and validation of a hand-held beta probe intended to be used as a visual mapping device to locate and confirm excision of (18)FDG-avid primary tumors and metastases in an animal model. We have demonstrated a device which can generate beta images from (18)FDG avid lesions in an animal model. It is feasible to image beta irradiation in animal models of cancer given (18)FDG. This technology may be applied to clinical mapping of tumors and/or their metastases in the operating room. Visual image depiction of malignancy may aid the surgeon in localization and excision of lesions of interest.

  17. Prototyping Practice

    DEFF Research Database (Denmark)

    Ramsgaard Thomsen, Mette; Tamke, Martin

    2015-01-01

    This paper examines the role of the prototyping in digital architecture. During the past decade, a new research field has emerged exploring the digital technology’s impact on the way we think, design and build our environment. In this practice the prototype, the pavilion, installation or demonstr......This paper examines the role of the prototyping in digital architecture. During the past decade, a new research field has emerged exploring the digital technology’s impact on the way we think, design and build our environment. In this practice the prototype, the pavilion, installation...

  18. A hand-held imaging probe for radio-guided surgery: physical performance and preliminary clinical experience

    International Nuclear Information System (INIS)

    Pitre, S.; Menard, L.; Charon, Y.; Solal, M.; Garbay, J.R.

    2003-01-01

    Improvements in the specificity of radiopharmaceutical compounds have been paralleled by an upsurge of interest in developing small detectors to assist surgeons in localizing tumour tissue during surgery. This study reports the main technical features and physical characteristics of a new hand-held gamma camera dedicated to accurate and real-time intra-operative imaging. First clinical experience is also reported. The POCI (Per-operative Compact Imager) camera consists of a head module composed of a high-resolution interchangeable lead collimator and a CsI(Na) crystal plate optically coupled to an intensified position-sensitive diode. The current prototype has a 40-mm diameter field of view, an outer diameter of 9.5 cm, a length of 9 cm and a weight of 1.2 kg. Overall detector imaging characteristics were evaluated by technetium-99m phantom measurements. Three patients with breast cancer previously scheduled to undergo sentinel lymph node detection were selected for the preliminary clinical experience. Preoperative images of the lymphatic basin obtained using the POCI camera were compared with conventional transcutaneous explorations using a non-imaging gamma probe. The full-width at half-maximum (FWHM) spatial resolution was investigated in both air and scattering medium; when the phantom was placed in contact with the collimator, the POCI camera exhibited a 3.2 mm FWHM. The corresponding sensitivity was 290 cps/MBq. The preliminary clinical results showed that POCI was able to predict the number and location of all SLNs. In one case, two deep radioactive nodes missed by the gamma probe were detected on the intra-operative images. This very initial experience demonstrates that the physical performance of the POCI camera is adequate for radio-guided surgery. These results are sufficiently encouraging to prompt further evaluation studies designed to determine the specific and optimal clinical role of intra-operative imaging devices

  19. Video Browsing on Handheld Devices

    Science.gov (United States)

    Hürst, Wolfgang

    Recent improvements in processing power, storage space, and video codec development enable users now to playback video on their handheld devices in a reasonable quality. However, given the form factor restrictions of such a mobile device, screen size still remains a natural limit and - as the term "handheld" implies - always will be a critical resource. This is not only true for video but any data that is processed on such devices. For this reason, developers have come up with new and innovative ways to deal with large documents in such limited scenarios. For example, if you look at the iPhone, innovative techniques such as flicking have been introduced to skim large lists of text (e.g. hundreds of entries in your music collection). Automatically adapting the zoom level to, for example, the width of table cells when double tapping on the screen enables reasonable browsing of web pages that have originally been designed for large, desktop PC sized screens. A multi touch interface allows you to easily zoom in and out of large text documents and images using two fingers. In the next section, we will illustrate that advanced techniques to browse large video files have been developed in the past years, as well. However, if you look at state-of-the-art video players on mobile devices, normally just simple, VCR like controls are supported (at least at the time of this writing) that only allow users to just start, stop, and pause video playback. If supported at all, browsing and navigation functionality is often restricted to simple skipping of chapters via two single buttons for backward and forward navigation and a small and thus not very sensitive timeline slider.

  20. Operating performance of the gamma-ray Cherenkov telescope: An end-to-end Schwarzschild–Couder telescope prototype for the Cherenkov Telescope Array

    Energy Technology Data Exchange (ETDEWEB)

    Dournaux, J.L., E-mail: jean-laurent.dournaux@obspm.fr [GEPI, Observatoire de Paris, PSL Research University, CNRS, Sorbonne Paris Cité, Université Paris Diderot, Place J. Janssen, 92190 Meudon (France); De Franco, A. [Department of Physics, University of Oxford, Keble Road, Oxford OX1 3RH (United Kingdom); Laporte, P. [GEPI, Observatoire de Paris, PSL Research University, CNRS, Sorbonne Paris Cité, Université Paris Diderot, Place J. Janssen, 92190 Meudon (France); White, R. [Max-Planck-Institut für Kernphysik, Saupfercheckweg 1, 69117 Heidelberg (Germany); Greenshaw, T. [University of Liverpool, Oliver Lodge Laboratory, P.O. Box 147, Oxford Street, Liverpool L69 3BX (United Kingdom); Sol, H. [LUTH, Observatoire de Paris, PSL Research University, CNRS, Université Paris Diderot, Place J. Janssen, 92190 Meudon (France); Abchiche, A. [CNRS, Division technique DT-INSU, 1 Place Aristide Briand, 92190 Meudon (France); Allan, D. [Department of Physics and Centre for Advanced Instrumentation, Durham University, South Road, Durham DH1 3LE (United Kingdom); Amans, J.P. [GEPI, Observatoire de Paris, PSL Research University, CNRS, Sorbonne Paris Cité, Université Paris Diderot, Place J. Janssen, 92190 Meudon (France); Armstrong, T.P. [Department of Physics and Centre for Advanced Instrumentation, Durham University, South Road, Durham DH1 3LE (United Kingdom); Balzer, A.; Berge, D. [GRAPPA, University of Amsterdam, Science Park 904, 1098 XH Amsterdam (Netherlands); Boisson, C. [LUTH, Observatoire de Paris, PSL Research University, CNRS, Université Paris Diderot, Place J. Janssen, 92190 Meudon (France); and others

    2017-02-11

    The Cherenkov Telescope Array (CTA) consortium aims to build the next-generation ground-based very-high-energy gamma-ray observatory. The array will feature different sizes of telescopes allowing it to cover a wide gamma-ray energy band from about 20 GeV to above 100 TeV. The highest energies, above 5 TeV, will be covered by a large number of Small-Sized Telescopes (SSTs) with a field-of-view of around 9°. The Gamma-ray Cherenkov Telescope (GCT), based on Schwarzschild–Couder dual-mirror optics, is one of the three proposed SST designs. The GCT is described in this contribution and the first images of Cherenkov showers obtained using the telescope and its camera are presented. These were obtained in November 2015 in Meudon, France.

  1. Augmented Reality Simulations on Handheld Computers

    Science.gov (United States)

    Squire, Kurt; Klopfer, Eric

    2007-01-01

    Advancements in handheld computing, particularly its portability, social interactivity, context sensitivity, connectivity, and individuality, open new opportunities for immersive learning environments. This article articulates the pedagogical potential of augmented reality simulations in environmental engineering education by immersing students in…

  2. Handheld CAT Video Game, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed project is to design, develop and fabricate a handheld video game console for astronauts during long space flight. This portable hardware runs...

  3. Unikabeton Prototype

    DEFF Research Database (Denmark)

    Søndergaard, Asbjørn; Dombernowsky, Per

    2011-01-01

    The Unikabeton prototype structure was developed as the finalization of the cross-disciplinary research project Unikabeton, exploring the architectural potential in linking the computational process of topology optimisation with robot fabrication of concrete casting moulds. The project was elabor......The Unikabeton prototype structure was developed as the finalization of the cross-disciplinary research project Unikabeton, exploring the architectural potential in linking the computational process of topology optimisation with robot fabrication of concrete casting moulds. The project...... of Architecture was to develop a series of optimisation experiments, concluding in the design and optimisation of a full scale prototype concrete structure....

  4. Solution Prototype

    DEFF Research Database (Denmark)

    Efeoglu, Arkin; Møller, Charles; Serie, Michel

    2013-01-01

    This paper outlines an artifact building and evaluation proposal. Design Science Research (DSR) studies usually consider encapsulated artifact that have relationships with other artifacts. The solution prototype as a composed artifact demands for a more comprehensive consideration in its systematic...... environment. The solution prototype that is composed from blending product and service prototype has particular impacts on the dualism of DSR’s “Build” and “Evaluate”. Since the mix between product and service prototyping can be varied, there is a demand for a more agile and iterative framework. Van de Ven......’s research framework seems to fit this purpose. Van de Ven allows for an iterative research approach to problem solving with flexible starting point. The research activity is the result between the iteration of two dimensions. This framework focuses on the natural evaluation, particularly on ex...

  5. Software Prototyping

    Science.gov (United States)

    Del Fiol, Guilherme; Hanseler, Haley; Crouch, Barbara Insley; Cummins, Mollie R.

    2016-01-01

    Summary Background Health information exchange (HIE) between Poison Control Centers (PCCs) and Emergency Departments (EDs) could improve care of poisoned patients. However, PCC information systems are not designed to facilitate HIE with EDs; therefore, we are developing specialized software to support HIE within the normal workflow of the PCC using user-centered design and rapid prototyping. Objective To describe the design of an HIE dashboard and the refinement of user requirements through rapid prototyping. Methods Using previously elicited user requirements, we designed low-fidelity sketches of designs on paper with iterative refinement. Next, we designed an interactive high-fidelity prototype and conducted scenario-based usability tests with end users. Users were asked to think aloud while accomplishing tasks related to a case vignette. After testing, the users provided feedback and evaluated the prototype using the System Usability Scale (SUS). Results Survey results from three users provided useful feedback that was then incorporated into the design. After achieving a stable design, we used the prototype itself as the specification for development of the actual software. Benefits of prototyping included having 1) subject-matter experts heavily involved with the design; 2) flexibility to make rapid changes, 3) the ability to minimize software development efforts early in the design stage; 4) rapid finalization of requirements; 5) early visualization of designs; 6) and a powerful vehicle for communication of the design to the programmers. Challenges included 1) time and effort to develop the prototypes and case scenarios; 2) no simulation of system performance; 3) not having all proposed functionality available in the final product; and 4) missing needed data elements in the PCC information system. PMID:27081404

  6. A BODIPY-Based Fluorescent Probe to Visually Detect Phosgene: Toward the Development of a Handheld Phosgene Detector.

    Science.gov (United States)

    Sayar, Melike; Karakuş, Erman; Güner, Tuğrul; Yildiz, Busra; Yildiz, Umit Hakan; Emrullahoğlu, Mustafa

    2018-03-02

    A boron-dipyrromethene (BODIPY)-based fluorescent probe with a phosgene-specific reactive motif shows remarkable selectivity toward phosgene, in the presence of which the nonfluorescent dye rapidly transforms into a new structure and induces a fluorescent response clearly observable to the naked eye under ultraviolet light. Given that dynamic, a prototypical handheld phosgene detector with a promising sensing capability that expedites the detection of gaseous phosgene without sophisticated instrumentation was developed. The proposed method using the handheld detector involves a rapid response period suitable for issuing early warnings during emergency situations. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Proprioceptive evoked gamma oscillations

    DEFF Research Database (Denmark)

    Arnfred, S.M.; Hansen, Lars Kai; Parnas, J.

    2007-01-01

    A proprioceptive stimulus consisting of a weight change of a handheld load has recently been shown to elicit an evoked potential. Previously, somatosensory gamma oscillations have only been evoked by electrical stimuli. We conjectured that a natural proprioceptive stimulus also would be able...... to evoke gamma oscillations. EEG was recorded using 64 channels in 14 healthy subjects. In each of three runs a stimulus of 100 g load increment in each hand was presented in 120 trials. Data were wavelet transformed and runs collapsed. Inter-trial phase coherence (ITPC) was computed as the best measure...

  8. Possibility of observing high energy neutrinos from gamma bursts, with the Antanares telescope, feasibility study; Possibilite d'observation, par le telescope antares, de neutrinos de haute energie associes aux sursauts gamma et validation des techniques de detection a l'aide d'un prototype

    Energy Technology Data Exchange (ETDEWEB)

    Kouchner, A

    2001-04-01

    The European Antares collaboration intends to build a deep-sea neutrino telescope with a detection surface of about 1/10 km{sup 2} in the Mediterranean sea. The universe is transparent to neutrinos, so their study provides a unique means of improving our knowledge of the nature and origin of cosmic rays and their emission from the most powerful astrophysical sources in the cosmos. Neutrinos also offer the possibility of opening a new energy window (E>TeV) for observation of the universe. The first part of the thesis is dedicated to a study of the possibility of using the future telescope to look for correlations between gamma-ray bursts and high-energy neutrinos. It is based, on one hand, on the predictions of neutrino fluxes from gamma-ray bursts in the framework of the theoretical model of 'fireballs', and, on the other hand, on the temporal properties of the gamma-ray bursts in the 4. BATSE catalogue. The second part of the thesis presents the results obtained with a prototype detector line deployed, at the end of 1999, some forty km south-west off Marseilles. The objective was to operate a complete apparatus, similar to the future detector lines, from the shore, and under realistic conditions. Data from 7 photomultiplier tubes disposed along the detector line were transmitted through 37 km of optical fiber to the shore, where they were used to reconstruct tracks due to atmospheric muons, thus validating the detection principles and methods. (author)

  9. 30 CFR 57.12033 - Hand-held electric tools.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...

  10. 30 CFR 56.12033 - Hand-held electric tools.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held electric tools. 56.12033 Section 56.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL....12033 Hand-held electric tools. Hand-held electric tools shall not be operated at high potential...

  11. Handheld Versus Wearable Interaction Design for Professionals - A Case Study of Hospital Service Work

    DEFF Research Database (Denmark)

    Stisen, Allan; Blunck, Henrik; Kjærgaard, Mikkel Baun

    2014-01-01

    With the blooming of new available wrist worn devices there are potentials for these to support the work done in many professional domains. One such domain is hospital service work. This paper explores two wearable prototypes with regards to challenges and opportunities to support future hospital...... service work. This explorative study was conducted with 4 experienced hospital orderlies who interacted with an application across two wearable concepts, and one handheld smartphone in five scenarios in a hospital environment. The interaction was video recorded with a chest-mounted video afterwards semi...... structured interviews with each participant was conducted. This study shows that wearable computers can effectively support the maintenance work of the orderlies and has domain specific advantages over the handheld smartphone, e.g., the former support glancing at the task information. Furthermore, we outline...

  12. New portable hand-held radiation instruments for measurements and monitoring

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1987-01-01

    Hand-held radiation monitors are often used to search pedestrians and motor vehicles for special nuclear material (SNM) as part of a physical protection plan for nuclear materials. Recently, the Los Alamos Advanced Nuclear Technology group has commercialized an improved hand-held monitor that can be used for both physical-protection monitoring and verification measurements in nuclear material control and waste management. The new monitoring instruments are smaller and lighter; operate much longer on a battery charge; are available with NaI(Tl) or neutron and gamma-ray sensitive plastic scintillation detectors; and are less expensive than other comparable instruments. They also have a second operating mode for making precise measurements over counting times as long as 99 s. This mode permits making basic verification measurements that may be needed before transporting nuclear material or waste outside protected areas. Improved verification measurements can be made with a second new hand-held instrument that has a stabilized detector and three separate gamma-ray energy windows to obtain spectral information for SNM quantity, enrichment, or material-type verification

  13. Handheld Computers in Education: An Industry Perspective

    Science.gov (United States)

    van 't Hooft, Mark; Vahey, Philip

    2007-01-01

    Five representatives from the mobile computing industry provide their perspectives on handhelds in education. While some of their ideas differ, they all agree on the importance of staff development, appropriate curriculum development, and teacher support to create the kinds of personalized learning environments that mobile devices make possible.

  14. Handheld spectrometers: the state of the art

    Science.gov (United States)

    Crocombe, Richard A.

    2013-05-01

    "Small" spectrometers fall into three broad classes: small versions of laboratory instruments, providing data, subsequently processed on a PC; dedicated analyzers, providing actionable information to an individual operator; and process analyzers, providing quantitative or semi-quantitative information to a process controller. The emphasis of this paper is on handheld dedicated analyzers. Many spectrometers have historically been large, possible fragile, expensive and complicated to use. The challenge over the last dozen years, as instruments have moved into the field, has been to make spectrometers smaller, affordable, rugged, easy-to-use, but most of all capable of delivering actionable results. Actionable results can dramatically improve the efficiency of a testing process and transform the way business is done. There are several keys to this handheld spectrometer revolution. Consumer electronics has given us powerful mobile platforms, compact batteries, clearly visible displays, new user interfaces, etc., while telecomm has revolutionized miniature optics, sources and detectors. While these technologies enable miniature spectrometers themselves, actionable information has demanded the development of rugged algorithms for material confirmation, unknown identification, mixture analysis and detection of suspicious materials in unknown matrices. These algorithms are far more sophisticated than the `correlation' or `dot-product' methods commonly used in benchtop instruments. Finally, continuing consumer electronics advances now enable many more technologies to be incorporated into handheld spectrometers, including Bluetooth, wireless, WiFi, GPS, cameras and bar code readers, and the continued size shrinkage of spectrometer `engines' leads to the prospect of dual technology or `hyphenated' handheld instruments.

  15. Study of neutrino production in the Cannonball model of Gamma ray bursts: possibility of observation of these neutrinos with the Antares neutrinos telescope, and study of the optical background recorded with the prototype sector line

    International Nuclear Information System (INIS)

    Ferry, S.

    2004-09-01

    ANTARES is a future neutrino telescope which will be build at 40 km off the french coast (Toulon), at a 2500 m depth. The interaction of a neutrino with matter produces a muon which emits Cerenkov light while propagating in water. This light is detected with 900 photomultipliers distributed over 12 lines. Gamma ray bursts (GRB) are violent cosmological phenomenon observed once per day. In the Cannonball Model, bursts are produced by the interaction of a jet made of cannonballs (CB) with a supernova remnant (SNR). Forward shocks propagate in the SNR, reverse ones in the CB and neutrinos are produced at the shock fronts. An estimation of the neutrino production is given and is studied over a large parameter range. For a typical GRB, 0.002 to 0.3 v μ , cm -2 can be produced. Depending on the viewing angle, ANTARES could detect 1 to 10 v μ per year in correlation with GRBs. The ambient optical background has been recorded by the ANTARES prototype sector line. The analysis is about the background influence on the detector performance and about the organisms activity which produces it. For example, it appears a 17.6 to 20.4 h periodicity which is compatible with the liquid masses movement imposed by the Coriolis force at the ANTARES latitude. (author)

  16. Study of neutrino production in the Cannonball model of Gamma ray bursts: possibility of observation of these neutrinos with the Antares neutrinos telescope, and study of the optical background recorded with the prototype sector line; Etude de la production de neutrinos associes aux Sursauts Gamma dans le modele du Boulet de canon: possibilite d'observation de ces neutrinos par le detecteur ANTARES, et etude du bruit de fond optique enregistre par le prototype d'un secteur de ligne

    Energy Technology Data Exchange (ETDEWEB)

    Ferry, S

    2004-09-15

    ANTARES is a future neutrino telescope which will be build at 40 km off the french coast (Toulon), at a 2500 m depth. The interaction of a neutrino with matter produces a muon which emits Cerenkov light while propagating in water. This light is detected with 900 photomultipliers distributed over 12 lines. Gamma ray bursts (GRB) are violent cosmological phenomenon observed once per day. In the Cannonball Model, bursts are produced by the interaction of a jet made of cannonballs (CB) with a supernova remnant (SNR). Forward shocks propagate in the SNR, reverse ones in the CB and neutrinos are produced at the shock fronts. An estimation of the neutrino production is given and is studied over a large parameter range. For a typical GRB, 0.002 to 0.3 v{sub {mu}}, cm{sup -2} can be produced. Depending on the viewing angle, ANTARES could detect 1 to 10 v{sub {mu}} per year in correlation with GRBs. The ambient optical background has been recorded by the ANTARES prototype sector line. The analysis is about the background influence on the detector performance and about the organisms activity which produces it. For example, it appears a 17.6 to 20.4 h periodicity which is compatible with the liquid masses movement imposed by the Coriolis force at the ANTARES latitude. (author)

  17. Possibility of observing high energy neutrinos from gamma bursts, with the Antanares telescope, feasibility study; Possibilite d'observation, par le telescope antares, de neutrinos de haute energie associes aux sursauts gamma et validation des techniques de detection a l'aide d'un prototype

    Energy Technology Data Exchange (ETDEWEB)

    Kouchner, A

    2001-04-01

    The European Antares collaboration intends to build a deep-sea neutrino telescope with a detection surface of about 1/10 km{sup 2} in the Mediterranean sea. The universe is transparent to neutrinos, so their study provides a unique means of improving our knowledge of the nature and origin of cosmic rays and their emission from the most powerful astrophysical sources in the cosmos. Neutrinos also offer the possibility of opening a new energy window (E>TeV) for observation of the universe. The first part of the thesis is dedicated to a study of the possibility of using the future telescope to look for correlations between gamma-ray bursts and high-energy neutrinos. It is based, on one hand, on the predictions of neutrino fluxes from gamma-ray bursts in the framework of the theoretical model of 'fireballs', and, on the other hand, on the temporal properties of the gamma-ray bursts in the 4. BATSE catalogue. The second part of the thesis presents the results obtained with a prototype detector line deployed, at the end of 1999, some forty km south-west off Marseilles. The objective was to operate a complete apparatus, similar to the future detector lines, from the shore, and under realistic conditions. Data from 7 photomultiplier tubes disposed along the detector line were transmitted through 37 km of optical fiber to the shore, where they were used to reconstruct tracks due to atmospheric muons, thus validating the detection principles and methods. (author)

  18. Science with the ASTRI prototype

    International Nuclear Information System (INIS)

    Sartore, Nicola

    2013-01-01

    ASTRI (Astrofisica a Specchi con Tecnologia Replicante Italiana) is a “Flagship Project” financed by the Italian Ministry of Instruction, University and Research and led by the Italian National Institute of Astrophysics. It represents the Italian proposal for the development of the Small Size Telescope system of the Cherenkov Telescope Array, the next generation observatory for Very High Energy gamma-rays (20 GeV - 100 TeV). The ASTRI end-to-end prototype will be installed at Serra La Nave (Catania, Italy) and it will see the first light at the beginning of 2014. We describe the expected performance of the prototype on few selected test cases of the northern emisphere. The aim of the prototype is to probe the technological solutions and the nominal performance of the various telescope's subsystems

  19. Neurosurgical hand-held optical coherence tomography (OCT) forward-viewing probe

    Science.gov (United States)

    Sun, Cuiru; Lee, Kenneth K. C.; Vuong, Barry; Cusimano, Michael; Brukson, Alexander; Mariampillai, Adrian; Standish, Beau A.; Yang, Victor X. D.

    2012-02-01

    A prototype neurosurgical hand-held optical coherence tomography (OCT) imaging probe has been developed to provide micron resolution cross-sectional images of subsurface tissue during open surgery. This new ergonomic hand-held probe has been designed based on our group's previous work on electrostatically driven optical fibers. It has been packaged into a catheter probe in the familiar form factor of the clinically accepted Bayonet shaped neurosurgical non-imaging Doppler ultrasound probes. The optical design was optimized using ZEMAX simulation. Optical properties of the probe were tested to yield an ~20 um spot size, 5 mm working distance and a 3.5 mm field of view. The scan frequency can be increased or decreased by changing the applied voltage. Typically a scan frequency of less than 60Hz is chosen to keep the applied voltage to less than 2000V. The axial resolution of the probe was ~15 um (in air) as determined by the OCT system. A custom-triggering methodology has been developed to provide continuous stable imaging, which is crucial for clinical utility. Feasibility of this probe, in combination with a 1310 nm swept source OCT system was tested and images are presented to highlight the usefulness of such a forward viewing handheld OCT imaging probe. Knowledge gained from this research will lay the foundation for developing new OCT technologies for endovascular management of cerebral aneurysms and transsphenoidal neuroendoscopic treatment of pituitary tumors.

  20. Characterizing the reflectivity of handheld display devices.

    Science.gov (United States)

    Liu, Peter; Badano, Aldo

    2014-08-01

    With increased use of handheld and tablet display devices for viewing medical images, methods for consistently measuring reflectivity of the devices are needed. In this note, the authors report on the characterization of diffuse reflections for handheld display devices including mobile phones and tablets using methods recommended by the American Association of Physicists in Medicine Task Group 18 (TG18). The authors modified the diffuse reflectance coefficient measurement method outlined in the TG18 report. The authors measured seven handheld display devices (two phones and five tablets) and three workstation displays. The device was attached to a black panel with Velcro. To study the effect of the back surface on the diffuse reflectance coefficient, the authors created Styrofoam masks with different size square openings and placed it in front of the device. Overall, for each display device, measurements of illuminance and reflected luminance on the display screen were taken. The authors measured with no mask, with masks of varying size, and with display-size masks, and calculated the corresponding diffuse reflectance coefficient. For all handhelds, the diffuse reflectance coefficient measured with no back panel were lower than measurements performed with a mask. The authors found an overall increase in reflectivity as the size of the mask decreases. For workstations displays, diffuse reflectance coefficients were higher when no back panel was used, and higher than with masks. In all cases, as luminance increased, illuminance increased, but not at the same rate. Since the size of handheld displays is smaller than that of workstation devices, the TG18 method suffers from a dependency on illumination condition. The authors show that the diffuse reflection coefficients can vary depending on the nature of the back surface of the illuminating box. The variability in the diffuse coefficient can be as large as 20% depending on the size of the mask. For all measurements

  1. Multimodal ophthalmic imaging using handheld spectrally encoded coherence tomography and reflectometry (SECTR)

    Science.gov (United States)

    Leeburg, Kelsey C.; El-Haddad, Mohamed T.; Malone, Joseph D.; Terrones, Benjamin D.; Tao, Yuankai K.

    2018-02-01

    Scanning laser ophthalmoscopy (SLO) provides high-speed, noninvasive en face imaging of the retinal fundus. Optical coherence tomography (OCT) is the current "gold-standard" for ophthalmic diagnostic imaging and enables depth-resolved visualization of ophthalmic structures and image-based surrogate biomarkers of disease. We present a compact optical and mechanical design for handheld spectrally encoded coherence tomography and reflectometry (SECTR) for multimodality en face spectrally encoded reflectometry (SER) and cross-sectional OCT imaging. We custom-designed a double-pass telecentric scan lens, which halves the size of 4-f optical relays and allowed us to reduce the footprint of our SECTR scan-head by a factor of >2.7x (volume) over our previous design. The double-pass scan lens was optimized for diffraction-limited performance over a +/-10° scan field. SECTR optics and optomechanics were combined in a compact rapid-prototyped enclosure with dimensions 87 x 141.8 x 137 mm (w x h x d). SECTR was implemented using a custom-built 400 kHz 1050 nm swept-source. OCT and SER were simultaneously digitized on dual input channels of a 4 GS/s digitizer at 1.4 GS/s per channel. In vivo human en face SER and cross-sectional OCT images were acquired at 350 fps. OCT volumes of 1000 B-scans were acquired in 2.86 s. We believe clinical translation of our compact handheld design will benefit point-of-care ophthalmic diagnostics in patients who are unable to be imaged on conventional slit-lamp based systems, such as infants and the bedridden. When combined with multi-volumetric registration methods, handheld SECTR will have advantages in motion-artifact free imaging over existing handheld technologies.

  2. SAFARI 2000 Atmospheric Aerosol Measurements, Hand-held Hazemeters, Zambia

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: In conjunction with the AERONET (AErosol RObotic NETwork) participation in SAFARI 2000, the USDA Forest Service deployed handheld hazemeters in western...

  3. Study of mixed programming gamma spectrum acquisition method based on MSP430F4618

    International Nuclear Information System (INIS)

    Li Yuezhong; Tang Bin; Zhang Zhongliang; Xie Xiaolin

    2012-01-01

    In order to reduce the hand-held gamma spectrometer measurements dead time and to complete the low-voltage and low-power design, the spectrum signal acquisition circuit is constituted by the ultra-low power microcontroller MSP430F4618 and its external signal conditioning circuit, anti-coincidence circuit interface and its on-chip sample hold and A/D converter. C language programming and assembly one have been used together. The sample hold and A/D conversion and spectrum acquisition programming is accomplished by assembly language, and the system monitoring and task scheduler designing is accomplished by C language programming. The handhold gamma spectrometer power supply, which just uses two No.5 rechargeable batteries, is designed by high-efficiency DC-DC circuit. The prototype gamma spectrometer is developed by the method, and its testing shows that the implementation of spectrum acquisition time is shorten by twice to 3 times, that is, the dead measurement can be reduced; and the machine operating current does not exceed 150 mA. By using two 2400 mAh No.5 rechargeable battery, the machine can work continuously more than 10 hours, and it can meet the application requirements. (authors)

  4. Hand-held and automated breast ultrasound

    International Nuclear Information System (INIS)

    Bassett, L.W.; Gold, R.H.; Kimme-Smith, C.

    1985-01-01

    The book is a guide for physicians and technologists who use US as an adjunct to mammography; it carefully outlines the pros and cons of US of the breast and its role in the diagnosis of benign and malignant diseases. After an introduction that discusses the philosophy of breast US, the chapters cover the physics of US and instrumentation (both hand-held transducers as well as automated water path scanners), then proceed to a discussion of the normal breast. Sections on benign disorders, malignant lesions, and pitfalls of diagnosis are followed by quiz cases

  5. Handheld emissions detector (HED): overview and development

    Science.gov (United States)

    Valentino, George J.; Schimmel, David

    2009-05-01

    Nova Engineering, Cincinnati OH, a division of L-3 Communications (L-3 Nova), under the sponsorship of Program Manager Soldier Warrior (PM-SWAR), Fort Belvoir, VA, has developed a Soldier portable, light-weight, hand-held, geolocation sensor and processing system called the Handheld Emissions Detector (HED). The HED is a broadband custom receiver and processor that allows the user to easily sense, direction find, and locate a broad range of emitters in the user's surrounding area. Now in its second design iteration, the HED incorporates a set of COTS components that are complemented with L-3 Nova custom RF, power, digital, and mechanical components, plus custom embedded and application software. The HED user interfaces are designed to provide complex information in a readily-understandable form, thereby providing actionable results for operators. This paper provides, where possible, the top-level characteristics of the HED as well as the rationale behind its design philosophy along with its applications in both DOD and Commercial markets.

  6. Navigating on handheld displays: Dynamic versus Static Keyhole Navigation

    NARCIS (Netherlands)

    Mehra, S.; Werkhoven, P.; Worring, M.

    2006-01-01

    Handheld displays leave little space for the visualization and navigation of spatial layouts representing rich information spaces. The most common navigation method for handheld displays is static peephole navigation: The peephole is static and we move the spatial layout behind it (scrolling). A

  7. A Cognitive Style Perspective to Handheld Devices: Customization vs. Personalization

    Science.gov (United States)

    Hsieh, Chen-Wei; Chen, Sherry Y.

    2016-01-01

    Handheld devices are widely applied to support open and distributed learning, where students are diverse. On the other hand, customization and personalization can be applied to accommodate students' diversities. However, paucity of research compares the effects of customization and personalization in the context of handheld devices. To this end, a…

  8. A NEARBY GAMMA-RAY BURST HOST PROTOTYPE FOR z ∼ 7 LYMAN-BREAK GALAXIES: SPITZER-IRS AND X-SHOOTER SPECTROSCOPY OF THE HOST GALAXY OF GRB 031203

    International Nuclear Information System (INIS)

    Watson, D.; French, J.; Hjorth, J.; Malesani, D.; Fynbo, J. P. U.; Castro Cerón, J. M.; Christensen, L.; O'Halloran, B.; Michałowski, M.; Gordon, K. D.; Covino, S.; Reinfrank, R. F.

    2011-01-01

    Gamma-ray burst (GRB) host galaxies have been studied extensively in optical photometry and spectroscopy. Here we present the first mid-infrared spectrum of a GRB host, HG 031203. It is one of the nearest GRB hosts at z = 0.1055, allowing both low- and high-resolution spectroscopy with the Spitzer Infrared Spectrograph (IRS). Medium-resolution UV to K-band spectroscopy with the X-shooter spectrograph on the Very Large Telescope is also presented, along with Spitzer IRAC and MIPS photometry, as well as radio and submillimeter observations. These data allow us to construct a UV to radio spectral energy distribution with almost complete spectroscopic coverage from 0.3 to 35 μm of a GRB host galaxy for the first time, potentially valuable as a template for future model comparisons. The IRS spectra show strong, high-ionization fine structure line emission indicative of a hard radiation field in the galaxy—in particular the [S IV]/[S III] and [Ne III]/[Ne II] ratios—suggestive of strong ongoing star formation and a very young stellar population. The absence of any polycyclic aromatic hydrocarbon emission supports these conclusions, as does the probable hot peak dust temperature, making HG 031203 similar to the prototypical blue compact dwarf galaxy (BCD), II Zw 40. The selection of HG 031203 via the presence of a GRB suggests that it might be a useful analog of very young star-forming galaxies in the early universe, and hints that local BCDs may be used as more reliable analogs of star formation in the early universe than typical local starbursts. We look at the current debate on the ages of the dominant stellar populations in z ∼ 7 and z ∼ 8 galaxies in this context. The nebular line emission is so strong in HG 031203 that at z ∼ 7, it can reproduce the spectral energy distributions of z-band dropout galaxies with elevated IRAC 3.6 and 4.5 μm fluxes without the need to invoke a 4000 Å break. Indeed, photometry of HG 031203 shows elevation of the broadband V

  9. Handheld readout electronics to fully exploit the particle discrimination capabilities of elpasolite scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Budden, B.S., E-mail: bbudden@lanl.gov [Intelligence and Space Research Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Stonehill, L.C.; Warniment, A.; Michel, J.; Storms, S.; Dallmann, N.; Coupland, D.D.S.; Stein, P.; Weller, S.; Borges, L.; Proicou, M.; Duran, G. [Intelligence and Space Research Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Kamto, J. [Intelligence and Space Research Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Electrical & Computer Engineering Department, Praire View A& M University, Prairie View, TX 77446 (United States)

    2015-09-21

    A new class of elpasolite scintillators has garnered recent attention due to the ability to perform as simultaneous gamma spectrometers and thermal neutron detectors. Such a dual-mode capability is made possible by pulse-shape discrimination (PSD), whereby the emission waveform profiles of gamma and neutron events are fundamentally unique. To take full advantage of these materials, we have developed the Compact Advanced Readout Electronics for Elpasolites (CAREE). This handheld instrument employs a multi-channel PSD-capable ASIC, custom micro-processor board, front-end electronics, power supplies, and a 2 in. photomultiplier tube for readout of the scintillator. The unit is highly configurable to allow for performance optimization amongst a wide sample of elpasolites which provide PSD in fundamentally different ways. We herein provide an introduction to elpasolites, then describe the motivation for the work, mechanical and electronic design, and preliminary performance results.

  10. Image Quality Characteristics of Handheld Display Devices for Medical Imaging

    Science.gov (United States)

    Yamazaki, Asumi; Liu, Peter; Cheng, Wei-Chung; Badano, Aldo

    2013-01-01

    Handheld devices such as mobile phones and tablet computers have become widespread with thousands of available software applications. Recently, handhelds are being proposed as part of medical imaging solutions, especially in emergency medicine, where immediate consultation is required. However, handheld devices differ significantly from medical workstation displays in terms of display characteristics. Moreover, the characteristics vary significantly among device types. We investigate the image quality characteristics of various handheld devices with respect to luminance response, spatial resolution, spatial noise, and reflectance. We show that the luminance characteristics of the handheld displays are different from those of workstation displays complying with grayscale standard target response suggesting that luminance calibration might be needed. Our results also demonstrate that the spatial characteristics of handhelds can surpass those of medical workstation displays particularly for recent generation devices. While a 5 mega-pixel monochrome workstation display has horizontal and vertical modulation transfer factors of 0.52 and 0.47 at the Nyquist frequency, the handheld displays released after 2011 can have values higher than 0.63 at the respective Nyquist frequencies. The noise power spectra for workstation displays are higher than 1.2×10−5 mm2 at 1 mm−1, while handheld displays have values lower than 3.7×10−6 mm2. Reflectance measurements on some of the handheld displays are consistent with measurements for workstation displays with, in some cases, low specular and diffuse reflectance coefficients. The variability of the characterization results among devices due to the different technological features indicates that image quality varies greatly among handheld display devices. PMID:24236113

  11. Developing a compact multiple laser diode combiner with a single fiber stub output for handheld IoT devices

    Science.gov (United States)

    Lee, Minseok; June, Seunghyeok; Kim, Sehwan

    2018-01-01

    Many biomedical applications require an efficient combination and localization of multiple discrete light sources ( e.g., fluorescence and absorbance imaging). We present a compact 6 channel combiner that couples the output of independent solid-state light sources into a single 400-μm-diameter fiber stub for handheld Internet of Things (IoT) devices. We demonstrate average coupling efficiencies > 80% for each of the 6 laser diodes installed into the prototype. The design supports the use of continuous wave and intensity-modulated laser diodes. This fiber-stub-type beam combiner could be used to construct custom multi-wavelength sources for tissue oximeters, microscopes and molecular imaging technologies. In order to validate its suitability, we applied the developed fiber-stub-type beam combiner to a multi-wavelength light source for a handheld IoT device and demonstrated its feasibility for smart healthcare through a tumor-mimicking silicon phantom.

  12. Handheld Multi-Gas Meters Assessment Report

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Gustavious [Brigham Young Univ., Provo, UT (United States); Wald-Hopkins, Mark David [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Obrey, Stephen J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Akhadov, Valida Dushdurova [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-27

    Handheld multi-gas meters (MGMs) are equipped with sensors to monitor oxygen (O2) levels and additional sensors to detect the presence of combustible or toxic gases in the environment. This report is limited to operational response-type MGMs that include at least four different sensors. These sensors can vary by type and by the monitored chemical. In real time, the sensors report the concentration of monitored gases in the atmosphere near the MGM. In April 2016 the System Assessment and Validation for Emergency Responders (SAVER) Program conducted an operationally-oriented assessment of MGMs. Five MGMs were assessed by emergency responders. The criteria and scenarios used in this assessment were derived from the results of a focus group of emergency responders with experience in using MGMs. The assessment addressed 16 evaluation criteria in four SAVER categories: Usability, Capability, Maintainability, and Deployability.

  13. Handheld microwave bomb-detecting imaging system

    Science.gov (United States)

    Gorwara, Ashok; Molchanov, Pavlo

    2017-05-01

    Proposed novel imaging technique will provide all weather high-resolution imaging and recognition capability for RF/Microwave signals with good penetration through highly scattered media: fog, snow, dust, smoke, even foliage, camouflage, walls and ground. Image resolution in proposed imaging system is not limited by diffraction and will be determined by processor and sampling frequency. Proposed imaging system can simultaneously cover wide field of view, detect multiple targets and can be multi-frequency, multi-function. Directional antennas in imaging system can be close positioned and installed in cell phone size handheld device, on small aircraft or distributed around protected border or object. Non-scanning monopulse system allows dramatically decrease in transmitting power and at the same time provides increased imaging range by integrating 2-3 orders more signals than regular scanning imaging systems.

  14. Optical links in handheld multimedia devices

    Science.gov (United States)

    van Geffen, S.; Duis, J.; Miller, R.

    2008-04-01

    Ever emerging applications in handheld multimedia devices such as mobile phones, laptop computers, portable video games and digital cameras requiring increased screen resolutions are driving higher aggregate bitrates between host processor and display(s) enabling services such as mobile video conferencing, video on demand and TV broadcasting. Larger displays and smaller phones require complex mechanical 3D hinge configurations striving to combine maximum functionality with compact building volumes. Conventional galvanic interconnections such as Micro-Coax and FPC carrying parallel digital data between host processor and display module may produce Electromagnetic Interference (EMI) and bandwidth limitations caused by small cable size and tight cable bends. To reduce the number of signals through a hinge, the mobile phone industry, organized in the MIPI (Mobile Industry Processor Interface) alliance, is currently defining an electrical interface transmitting serialized digital data at speeds >1Gbps. This interface allows for electrical or optical interconnects. Above 1Gbps optical links may offer a cost effective alternative because of their flexibility, increased bandwidth and immunity to EMI. This paper describes the development of optical links for handheld communication devices. A cable assembly based on a special Plastic Optical Fiber (POF) selected for its mechanical durability is terminated with a small form factor molded lens assembly which interfaces between an 850nm VCSEL transmitter and a receiving device on the printed circuit board of the display module. A statistical approach based on a Lean Design For Six Sigma (LDFSS) roadmap for new product development tries to find an optimum link definition which will be robust and low cost meeting the power consumption requirements appropriate for battery operated systems.

  15. Correcting for motion artifact in handheld laser speckle images

    Science.gov (United States)

    Lertsakdadet, Ben; Yang, Bruce Y.; Dunn, Cody E.; Ponticorvo, Adrien; Crouzet, Christian; Bernal, Nicole; Durkin, Anthony J.; Choi, Bernard

    2018-03-01

    Laser speckle imaging (LSI) is a wide-field optical technique that enables superficial blood flow quantification. LSI is normally performed in a mounted configuration to decrease the likelihood of motion artifact. However, mounted LSI systems are cumbersome and difficult to transport quickly in a clinical setting for which portability is essential in providing bedside patient care. To address this issue, we created a handheld LSI device using scientific grade components. To account for motion artifact of the LSI device used in a handheld setup, we incorporated a fiducial marker (FM) into our imaging protocol and determined the difference between highest and lowest speckle contrast values for the FM within each data set (Kbest and Kworst). The difference between Kbest and Kworst in mounted and handheld setups was 8% and 52%, respectively, thereby reinforcing the need for motion artifact quantification. When using a threshold FM speckle contrast value (KFM) to identify a subset of images with an acceptable level of motion artifact, mounted and handheld LSI measurements of speckle contrast of a flow region (KFLOW) in in vitro flow phantom experiments differed by 8%. Without the use of the FM, mounted and handheld KFLOW values differed by 20%. To further validate our handheld LSI device, we compared mounted and handheld data from an in vivo porcine burn model of superficial and full thickness burns. The speckle contrast within the burn region (KBURN) of the mounted and handheld LSI data differed by burns. Collectively, our results suggest the potential of handheld LSI with an FM as a suitable alternative to mounted LSI, especially in challenging clinical settings with space limitations such as the intensive care unit.

  16. Rethink! prototyping transdisciplinary concepts of prototyping

    CERN Document Server

    Nagy, Emilia; Stark, Rainer

    2016-01-01

    In this book, the authors describe the findings derived from interaction and cooperation between scientific actors employing diverse practices. They reflect on distinct prototyping concepts and examine the transformation of development culture in their fusion to hybrid approaches and solutions. The products of tomorrow are going to be multifunctional, interactive systems – and already are to some degree today. Collaboration across multiple disciplines is the only way to grasp their complexity in design concepts. This underscores the importance of reconsidering the prototyping process for the development of these systems, particularly in transdisciplinary research teams. “Rethinking Prototyping – new hybrid concepts for prototyping” was a transdisciplinary project that took up this challenge. The aim of this programmatic rethinking was to come up with a general concept of prototyping by combining innovative prototyping concepts, which had been researched and developed in three sub-projects: “Hybrid P...

  17. Architectures of prototypes and architectural prototyping

    DEFF Research Database (Denmark)

    Hansen, Klaus Marius; Christensen, Michael; Sandvad, Elmer

    1998-01-01

    together as a team, but developed a prototype that more than fulfilled the expectations of the shipping company. The prototype should: - complete the first major phase within 10 weeks, - be highly vertical illustrating future work practice, - continuously live up to new requirements from prototyping......This paper reports from experience obtained through development of a prototype of a global customer service system in a project involving a large shipping company and a university research group. The research group had no previous knowledge of the complex business of shipping and had never worked...... sessions with users, - evolve over a long period of time to contain more functionality - allow for 6-7 developers working intensively in parallel. Explicit focus on the software architecture and letting the architecture evolve with the prototype played a major role in resolving these conflicting...

  18. SAFARI 2000 Atmospheric Aerosol Measurements, Hand-held Hazemeters, Zambia

    Data.gov (United States)

    National Aeronautics and Space Administration — In conjunction with the AERONET (AErosol RObotic NETwork) participation in SAFARI 2000, the USDA Forest Service deployed handheld hazemeters in western Zambia from...

  19. Handheld FRET-Aptamer Sensor for Water Safety, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Operational Technologies Corporation (OpTech) proposes to expand its current NASA Phase 2 SBIR handheld fluorometer and bone marker fluorescence resonance energy...

  20. The availability of relatively cheap hand-held Global Positioning ...

    African Journals Online (AJOL)

    spamer

    conditions, so the approach failed to produce results ... Hand-held Global Positioning System (GPS) receivers provide opportunities for detailed and rapid mapping of features ..... TICKELL, W. L. N. 1968 — The biology of the great albatrosses,.

  1. Rich internet application system for patient-centric healthcare data management using handheld devices.

    Science.gov (United States)

    Constantinescu, L; Pradana, R; Kim, J; Gong, P; Fulham, Michael; Feng, D

    2009-01-01

    Rich Internet Applications (RIAs) are an emerging software platform that blurs the line between web service and native application, and is a powerful tool for handheld device deployment. By democratizing health data management and widening its availability, this software platform has the potential to revolutionize telemedicine, clinical practice, medical education and information distribution, particularly in rural areas, and to make patient-centric medical computing a reality. In this paper, we propose a telemedicine application that leverages the ability of a mobile RIA platform to transcode, organise and present textual and multimedia data, which are sourced from medical database software. We adopted a web-based approach to communicate, in real-time, with an established hospital information system via a custom RIA. The proposed solution allows communication between handheld devices and a hospital information system for media streaming with support for real-time encryption, on any RIA enabled platform. We demonstrate our prototype's ability to securely and rapidly access, without installation requirements, medical data ranging from simple textual records to multi-slice PET-CT images and maximum intensity (MIP) projections.

  2. DNA aptamer beacon assay for C-telopeptide and handheld fluorometer to monitor bone resorption.

    Science.gov (United States)

    Bruno, John Gordon; Carrillo, Maria P; Phillips, Taylor; Hanson, Douglas; Bohmann, Jonathan A

    2011-09-01

    A novel DNA aptamer beacon is described for quantification of a 26-amino acid C-telopeptide (CTx) of human type I bone collagen. One aptamer sequence and its reverse complement dominated the aptamer pool (31.6% of sequenced clones). Secondary structures of these aptamers were examined for potential binding pockets. Three-dimensional computer models which analyzed docking topologies and binding energies were in agreement with empirical fluorescence experiments used to select one candidate loop for beacon assay development. All loop structures from the aptamer finalists were end-labeled with TYE 665 and Iowa Black quencher for comparison of beacon fluorescence levels as a function of CTx concentration. The optimal beacon, designated CTx 2R-2h yielded a low ng/ml limit of detection using a commercially available handheld fluorometer. The CTx aptamer beacon bound full-length 26-amino acid CTx peptide, but not a shorter 8-amino acid segment of CTx peptide which is a common target for commercial CTx ELISA kits. The prototype assay was shown to detect CTx peptide from human urine after creatinine and urea were removed by size-exclusion chromatography to prevent nonspecific denaturing of the aptamer beacon. This work demonstrates the potential of aptamer beacons to be utilized for rapid and sensitive bone health monitoring in a handheld or point-of-care format.

  3. Design and Implementation of an Intelligent Windowsill System Using Smart Handheld Device and Fuzzy Microcontroller.

    Science.gov (United States)

    Wang, Jing-Min; Yang, Ming-Ta; Chen, Po-Lin

    2017-04-11

    With the advance of science and technology, people have a desire for convenient and comfortable living. Creating comfortable and healthy indoor environments is a major consideration for designing smart homes. As handheld devices become increasingly powerful and ubiquitous, this paper proposes an innovative use of smart handheld devices (SHD), using MIT App Inventor and fuzzy control, to perform the real-time monitoring and smart control of the designed intelligent windowsill system (IWS) in a smart home. A compact weather station that consists of environment sensors was constructed in the IWS for measuring of indoor illuminance, temperature-humidity, carbon dioxide (CO₂) concentration and outdoor rain and wind direction. According to the measured environment information, the proposed system can automatically send a command to a fuzzy microcontroller performed by Arduino UNO to fully or partly open the electric curtain and electric window for adapting to climate changes in the indoor and outdoor environment. Moreover, the IWS can automatically close windows for rain splashing on the window. The presented novel control method for the windowsill not only expands the SHD applications, but greatly enhances convenience to users. To validate the feasibility and effectiveness of the IWS, a laboratory prototype was built and confirmed experimentally.

  4. Doctors' experience with handheld computers in clinical practice: qualitative study.

    Science.gov (United States)

    McAlearney, Ann Scheck; Schweikhart, Sharon B; Medow, Mitchell A

    2004-05-15

    To examine doctors' perspectives about their experiences with handheld computers in clinical practice. Qualitative study of eight focus groups consisting of doctors with diverse training and practice patterns. Six practice settings across the United States and two additional focus group sessions held at a national meeting of general internists. 54 doctors who did or did not use handheld computers. Doctors who used handheld computers in clinical practice seemed generally satisfied with them and reported diverse patterns of use. Users perceived that the devices helped them increase productivity and improve patient care. Barriers to use concerned the device itself and personal and perceptual constraints, with perceptual factors such as comfort with technology, preference for paper, and the impression that the devices are not easy to use somewhat difficult to overcome. Participants suggested that organisations can help promote handheld computers by providing advice on purchase, usage, training, and user support. Participants expressed concern about reliability and security of the device but were particularly concerned about dependency on the device and over-reliance as a substitute for clinical thinking. Doctors expect handheld computers to become more useful, and most seem interested in leveraging (getting the most value from) their use. Key opportunities with handheld computers included their use as a stepping stone to build doctors' comfort with other information technology and ehealth initiatives and providing point of care support that helps improve patient care.

  5. Introduction of handheld computing to a family practice residency program.

    Science.gov (United States)

    Rao, Goutham

    2002-01-01

    Handheld computers are valuable practice tools. It is important for residency programs to introduce their trainees and faculty to this technology. This article describes a formal strategy to introduce handheld computing to a family practice residency program. Objectives were selected for the handheld computer training program that reflected skills physicians would find useful in practice. TRGpro handheld computers preloaded with a suite of medical reference programs, a medical calculator, and a database program were supplied to participants. Training consisted of four 1-hour modules each with a written evaluation quiz. Participants completed a self-assessment questionnaire after the program to determine their ability to meet each objective. Sixty of the 62 participants successfully completed the training program. The mean composite score on quizzes was 36 of 40 (90%), with no significant differences by level of residency training. The mean self-ratings of participants across all objectives was 3.31 of 4.00. Third-year residents had higher mean self-ratings than others (mean of group, 3.62). Participants were very comfortable with practical skills, such as using drug reference software, and less comfortable with theory, such as knowing the different types of handheld computers available. Structured training is a successful strategy for introducing handheld computing to a residency program.

  6. Introducing Handheld Computing for Interactive Medical Education

    Directory of Open Access Journals (Sweden)

    Joseph Finkelstein

    2005-04-01

    Full Text Available The goals of this project were: (1 development of an interactive multimedia medical education tool (CO-ED utilizing modern features of handheld computing (PDA and major constructs of adult learning theories, and (2 pilot testing of the computer-assisted education in residents and clinicians. Comparison of the knowledge scores using paired t-test demonstrated statistically significant increase in subject knowledge (p<0.01 after using CO-ED. Attitudinal surveys were analyzed by total score (TS calculation represented as a percentage of a maximal possible score. The mean TS was 74.5±7.1%. None of the subjects (N=10 had TS less than 65% and in half of the subjects (N=5 TS was higher than 75%. Analysis of the semi-structured in-depth interviews showed strong support of the study subjects in using PDA as an educational tool, and high acceptance of CO-ED user interface. We concluded that PDA have a significant potential as a tool for clinician education.

  7. An Adaptive Geometry Game for Handheld Devices

    Directory of Open Access Journals (Sweden)

    Harri Ketamo

    2003-01-01

    Full Text Available The development of adaptive learning systems is only in the very beginning. In fact, the concept of adaptive learning systems range from different user interfaces to behaviour adaptive systems as well as from the place and time independent systems to terminal independent systems. When approaching the concept of adaptive learning materials, we must first have conceptual models of the behaviour of different learners within digital environments.The aim of this study was to develop a geometry learning game that adapts to user’s behaviour. The learners in this study were six years old Finnish pre-school pupils. The adaptive system was very limited and the observed behaviour was defined as very simple. However, the software developed achieves good learning results among the tested pupils. The study shows that the learning effect is very promising with this kind of handheld platform and simple adaptation system. This study gives good visions of what can be achieved with more complex behaviour adaptive systems in the field of eLearning.

  8. Extensional rheometry with a handheld mobile device

    Science.gov (United States)

    Marshall, Kristin A.; Liedtke, Aleesha M.; Todt, Anika H.; Walker, Travis W.

    2017-06-01

    The on-site characterization of complex fluids is important for a number of academic and industrial applications. Consequently, a need exists to develop portable rheometers that can provide in the field diagnostics and serve as tools for rapid quality assurance. With the advancement of smartphone technology and the widespread global ownership of smart devices, mobile applications are attractive as platforms for rheological characterization. The present work investigates the use of a smartphone device for the extensional characterization of a series of Boger fluids composed of glycerol/water and poly(ethylene oxide), taking advantage of the increasing high-speed video capabilities (currently up to 240 Hz capture rate at 720p) of smartphone cameras. We report a noticeable difference in the characterization of samples with slight variations in polymer concentration and discuss current device limitations. Potential benefits of a handheld extensional rheometer include its use as a point-of-care diagnostic tool, especially in developing communities, as well as a simple and inexpensive tool for assessing product quality in industry.

  9. Hand-held optical fuel pin scanner

    International Nuclear Information System (INIS)

    Kirchner, T.L.; Powers, H.G.

    1987-01-01

    A portable, hand-held apparatus is described for optically scanning indicia imprinted about a planar end face of an article having an outer wall surface, the apparatus comprising: a supporting frame; light detector means fixed to the frame for digitizing light patterns directed thereto; indexing means on the frame for engaging the planar end face and locating the end face in a preselected focal plane on the frame. The indexing means has an inner wall surface complementary to the article wall surface for disposition thereabout and terminates in an end portion beyond the planar end face. The inner wall surface has a radially inwardly extending shoulder spaced from the end portion and engageable with the planar end face; light means directed onto the preselected focal plane; optical means mounted on the frame about a central axis, the optical means being optically interposed between the indexing means and the light detector means for directing reflected light from the preselected focal plane to the light detector means and including a dove prism centrally aligned along the central axis; and means for selectively rotating the dove prism relative to the frame about the central axis to thereby rotate the image from the focal plane as transmitted to the light detector means

  10. Handheld Microneedle-Based Electrolyte Sensing Platform.

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Philip R. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Rivas, Rhiana [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Johnson, David [Aquila Technologies Group, Inc., Albuquerque, NM (United States); Edwards, Thayne L. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Koskelo, Markku [Aquila Technologies Group, Inc., Albuquerque, NM (United States); Shawa, Luay [Aquila Technologies Group, Inc., Albuquerque, NM (United States); Brener, Igal [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Chavez, Victor H. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Polsky, Ronen [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-11-01

    Sandia National Laboratories will provide technical assistance, within time and budget, to Requester on testing and analyzing a microneedle-based electrolyte sensing platform. Hollow microneedles will be fabricated at Sandia and integrated with a fluidic chip using plastic laminate prototyping technology available at Sandia. In connection with commercial ion selective electrodes the sensing platform will be tested for detection of electrolytes (sodium and/or potassium) within physiological relevant concent ration ranges.

  11. Evaluation of Handheld Scanners for Automotive Applications

    Directory of Open Access Journals (Sweden)

    Wadea Ameen

    2018-01-01

    Full Text Available The process of generating a computerized geometric model for an existing part is known as Reverse Engineering (RE. It is a very useful technique in product development and plays a significant role in automotive, aerospace, and medical industries. In fact, it has been getting remarkable attention in manufacturing industries owing to its advanced data acquisition technologies. The process of RE is based on two primary steps: data acquisition (also known as scanning and data processing. To facilitate point data acquisition, a variety of scanning systems is available with different capabilities and limitations. Although the optical control of 3D scanners is fully developed, still several factors can affect the quality of the scanned data. As a result, the proper selection of scanning parameters, such as resolution, laser power, shutter time, etc., becomes very crucial. This kind of investigation can be very helpful and provide its users with guidelines to identify the appropriate factors. Moreover, it is worth noting that no single system is ideal in all applications. Accordingly, this work has compared two portable (handheld systems based on laser scanning and white light optical scanning for automotive applications. A car door containing a free-form surface has been used to achieve the above-mentioned goal. The design of experiments has been employed to determine the effects of different scanning parameters and optimize them. The capabilities and limitations have been identified by comparing the two scanners in terms of accuracy, scanning time, triangle numbers, ease of use, and portability. Then, the relationships between the system capabilities and the application requirements have been established. The results revealed that the laser scanner performed better than the white light scanner in terms of accuracy, while the white light scanner performed better in terms of acquisition speed and triangle numbers.

  12. Design and development of a prototype hot spot identification system

    International Nuclear Information System (INIS)

    Jain, Amit; Thakur, Vaishali M.; Anilkumar, Rekha; Sawant, Pravin; Chaudhury, Probal; Pradeepkumar, K.S.

    2015-01-01

    The proper assessment of radiological environments inside nuclear facilities require accurate spatial mapping of the gamma ray field. A prototype Hotspot Identification System has been designed and developed in-house for gamma ray imaging by combining a gamma spectrometer with a pinhole collimator and a digital camera. The system can rapidly determine the location, distribution and intensity of gamma ray sources by carrying a scan of the suspected locations. The measured data was compared with simulated values for NaI(Tl) response, generated using the MCNP 4B Transport code. The data obtained by experimental and theoretical method are in good agreement. (author)

  13. Imagining the prototype

    OpenAIRE

    Brouwer, C. E.; Bhomer, ten, M.; Melkas, H.; Buur, J.

    2013-01-01

    This article reports on the analysis of a design session, employing conversation analysis. In the design session three experts and a designer discuss a prototype of a shirt, which has been developed with the input from these experts. The analysis focuses on the type of involvement of the participants with the prototype and how they explicate the points they make in the discussion with or without making use of the prototype. Three techniques for explicating design issues that exploit the proto...

  14. Simple Multiplexing Hand-Held Control Unit

    Science.gov (United States)

    Hannaford, Blake

    1989-01-01

    Multiplexer consists of series of resistors, each shunted by single-pole, single-throw switch. User operates switches by pressing buttons or squeezing triggers. Prototype includes three switches operated successfully in over 200 hours of system operations. Number of switches accommodated determined by signal-to-noise ratio of current source, noise induced in control unit and cable, and number of bits in output of analog-to-digital converter. Because many computer-contolled robots have extra analog-to-digital channels, such multiplexer added at little extra cost.

  15. Rapid Prototyping Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The ARDEC Rapid Prototyping (RP) Laboratory was established in December 1992 to provide low cost RP capabilities to the ARDEC engineering community. The Stratasys,...

  16. Fabrication and Prototyping Lab

    Data.gov (United States)

    Federal Laboratory Consortium — Purpose: The Fabrication and Prototyping Lab for composite structures provides a wide variety of fabrication capabilities critical to enabling hands-on research and...

  17. Study, development and clinical evaluation of a per-operative {gamma} imager; Etude, developpement et evaluation clinique d`un imageur {gamma} per-operatoire

    Energy Technology Data Exchange (ETDEWEB)

    Menard, Laurent [Inst. de Physique Nucleaire, Paris-11 Univ., 91 - Orsay (France)

    1999-01-19

    The precise localization and complete surgical ablation of tumors are one of the most important procedures in cancer treatment. In that context, the use, in operating room, of light hand-held detectors associated to radiopharmaceutical compounds for tumor labelling, plays a significant role in assisting surgeons in real-time detection of lesion. The POCI gamma imaging probe (Per-Operative Compact Imager), which is presented here, is precisely dedicated to improve the radio-guided operative cancer surgery efficiency by bringing a new tool discriminating between healthy and pathological tissues. To match the specifications of intra-operative detection, we chose to build our camera around an intensified position sensitive diode which appeared to be particularly suitable to achieve a high resolution small size imager. The optimal geometry of two gamma detection head modules, composed of parallel hole collimators and scintillation crystals, was then investigated by numerical simulations. From these technological solutions, a first prototype of POCI with a 24 mm diameter field of view has been developed. Its characterization has put forward a millimeter spatial resolution and a detection efficiency comparable to that of clinical gamma cameras and in agreement with the numerical predictions. Finally, in collaboration with Gustave Roussy, a first clinical evaluation of the POCI camera has been performed for sentinel ganglion pre-operative localization in patients afflicted by malignant melanomas or breast cancers. The preliminary results have already shown that the performances of POCI are compatible with intraoperative imaging purposes and suggest how this camera can boost the success rate of tumor removal surgeries for other cancerous diseases. (author) 100 refs., 67 figs., 11 tabs.

  18. Decisions at hand: a decision support system on handhelds.

    Science.gov (United States)

    Zupan, B; Porenta, A; Vidmar, G; Aoki, N; Bratko, I; Beck, J R

    2001-01-01

    One of the applications of clinical information systems is decision support. Although the advantages of utilizing such aids have never been theoretically disputed, they have been rarely used in practice. The factor that probably often limits the utility of clinical decision support systems is the need for computing power at the very site of decision making--at the place where the patient is interviewed, in discussion rooms, etc. The paper reports on a possible solution to this problem. A decision-support shell LogReg is presented, which runs on a handheld computer. A general schema for handheld-based decision support is also proposed, where decision models are developed on personal computers/workstations, encoded in XML and then transferred to handhelds, where the models are used within a decision support shell. A use case where LogReg has been applied to clinical outcome prediction in crush injury is presented.

  19. A Prototype User Interface for a Mobile Electronic Clinical Note Data Entry System

    OpenAIRE

    Zafar, Atif; Lehto, Mark; Kim, Jongseo

    2005-01-01

    Recent advances in mobile computing technologies have made electronic medical records (EMRs) on handheld devices an attractive possibility. However, data entry paradigms popular on desktop machines do not translate well to mobile devices1,2. Based on a review of the literature on mobile device usability1–4, we built a prototype user interface for mobile EMRs and held focus groups with clinician users whose feedback provided useful insight about design choices, functionality and...

  20. 75 FR 36678 - In the Matter of Certain Authentication Systems, Including Software and Handheld Electronic...

    Science.gov (United States)

    2010-06-28

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-697] In the Matter of Certain Authentication Systems, Including Software and Handheld Electronic Devices; Notice of Commission Decision Not to... importation of certain authentication systems, including software and handheld electronic devices, by reason...

  1. 75 FR 8400 - In the Matter of Certain Wireless Communications System Server Software, Wireless Handheld...

    Science.gov (United States)

    2010-02-24

    ... Communications System Server Software, Wireless Handheld Devices and Battery Packs; Notice of Investigation... within the United States after importation of certain wireless communications system server software... certain wireless communications system server software, wireless handheld devices or battery packs that...

  2. Designing and testing prototypes

    NARCIS (Netherlands)

    Vereijken, P.; Wijnands, F.; Stol, W.

    1995-01-01

    This second progress report focuses on designing a theoretical prototype by linking parameters to methods and designing the methods in this context until they are ready for initial testing. The report focuses also on testing and improving the prototype in general and the methods in particular until

  3. EUCLID ARCHIVE SYSTEM PROTOTYPE

    NARCIS (Netherlands)

    Belikov, Andrey; Williams, Owen; Droge, Bob; Tsyganov, Andrey; Boxhoorn, Danny; McFarland, John; Verdoes Kleijn, Gijs; Valentijn, E; Altieri, Bruno; Dabin, Christophe; Pasian, F.; Osuna, Pedro; Soille, P.; Marchetti, P.G.

    2014-01-01

    The Euclid Archive System prototype is a functional information system which is used to address the numerous challenges in the development of fully functional data processing system for Euclid. The prototype must support the highly distributed nature of the Euclid Science Ground System, with Science

  4. Specifications in software prototyping

    OpenAIRE

    Luqi; Chang, Carl K.; Zhu, Hong

    1998-01-01

    We explore the use of software speci®cations for software prototyping. This paper describes a process model for software prototyping, and shows how specifications can be used to support such a process via a cellular mobile phone switch example.

  5. EPCiR prototype

    DEFF Research Database (Denmark)

    2003-01-01

    A prototype of a residential pervasive computing platform based on OSGi involving among other a mock-up of an health care bandage.......A prototype of a residential pervasive computing platform based on OSGi involving among other a mock-up of an health care bandage....

  6. Cooperative Prototyping Experiments

    DEFF Research Database (Denmark)

    Bødker, Susanne; Grønbæk, Kaj

    1989-01-01

    This paper describes experiments with a design technique that we denote cooperative prototyping. The experiments consider design of a patient case record system for municipal dental clinics in which we used HyperCard, an off the shelf programming environment for the Macintosh. In the ecperiments we...... tried to achieve a fluent work-like evaluation of prototypes where users envisioned future work with a computer tool, at the same time as we made on-line modifications of prototypes in cooperation with the users when breakdown occur in their work-like evaluation. The experiments showed...... that it was possible to make a number of direct manipulation changes of prototypes in cooperation with the users, in interplay with their fluent work-like evaluation of these. However, breakdown occurred in the prototyping process when we reached the limits of the direct manipulation support for modification. From...

  7. Hand-held personnel and vehicle monitors

    International Nuclear Information System (INIS)

    Kunz, W.E.; Chambers, W.H.; Henry, C.N.; France, S.W.; Millegan, D.R.; Hastings, R.D.; Worth, G.M.

    1976-05-01

    A light, rugged monitor has been developed for special nuclear materials (SNM) searches at material-access and protection-area exits. This monitor accepts gamma-ray pulses from a NaI(Tl) detector, integrates for a preset counting interval (typically 0.3 s), and produces an audible alarm whenever the counts in the interval exceed the trip level that is a preset multiple of the stored background count. Because the monitor is silent except when the alarm is operating, personnel with little special training can conduct more effective searches in a noisy and distracting environment than they can with conventional audible monitoring of individual radiation counts. The monitor is also more sensitive than conventional monitors that provide audible indication of the count rate

  8. Accuracy of Handheld Blood Glucose Meters at High Altitude

    NARCIS (Netherlands)

    de Mol, Pieter; Krabbe, Hans G.; de Vries, Suzanna T.; Fokkert, Marion J.; Dikkeschei, Bert D.; Rienks, Rienk; Bilo, Karin M.; Bilo, Henk J. G.

    2010-01-01

    Background: Due to increasing numbers of people with diabetes taking part in extreme sports (e. g., high-altitude trekking), reliable handheld blood glucose meters (BGMs) are necessary. Accurate blood glucose measurement under extreme conditions is paramount for safe recreation at altitude. Prior

  9. Web-Based Spatial Training Using Handheld Touch Screen Devices

    Science.gov (United States)

    Martin-Dorta, Norena; Saorin, Jose Luis; Contero, Manuel

    2011-01-01

    This paper attempts to harness the opportunities for mobility and the new user interfaces that handheld touch screen devices offer, in a non-formal learning context, with a view to developing spatial ability. This research has addressed two objectives: first, analyzing the effects that training can have on spatial visualisation using the…

  10. Monitoring invasive plants using hand-held GIS technology

    Science.gov (United States)

    Theresa M. Mau-Crimmins; Barron J. Orr

    2005-01-01

    Successful control of invasive species requires a clear picture of the spatial extent of infestations. The latest mapping technology involves coupling global position systems and handheld computers running geographic information systems software in the field. A series of workshops applying this technology to mapping weeds was developed and presented to Weed Management...

  11. Technology-enabled division of labour: the use of handhelds

    NARCIS (Netherlands)

    Benders, J.G.J.M.; Schouteten, R.L.J.; Ruijsscher, C. de

    2012-01-01

    Using the task pool model and data from 15 establishments in the Dutch hospitality industry, this study shows how and why applying handhelds affects the division of labour. These devices allow to split the waiters' jobs into separate tasks which tend to be combined into two separate "sub jobs": the

  12. Technology-enabled division of labour : The use of handhelds

    NARCIS (Netherlands)

    Benders, J.G.J.M.; Schouteten, R.; de Ruijsscher, C.

    2012-01-01

    Using the task pool model and data from 15 establishments in the Dutch hospitality industry, this study shows how and why applying handhelds affects the division of labour. These devices allow to split the waiters' jobs into separate tasks which tend to be combined into two separate "sub jobs": the

  13. Diagnostic efficacy of handheld devices for emergency radiologic consultation.

    LENUS (Irish Health Repository)

    Toomey, Rachel J

    2010-02-01

    Orthopedic injury and intracranial hemorrhage are commonly encountered in emergency radiology, and accurate and timely diagnosis is important. The purpose of this study was to determine whether the diagnostic accuracy of handheld computing devices is comparable to that of monitors that might be used in emergency teleconsultation.

  14. Exploring streamwater mixing dynamics via handheld thermal infrared imagery

    NARCIS (Netherlands)

    Antonelli, Marta; Klaus, Julian; Smettem, Keith; Teuling, Ryan; Pfister, Laurent

    2017-01-01

    Stream confluences are important hotspots of aquatic ecological processes. Water mixing dynamics at stream confluences influence physio-chemical characteristics of the stream as well as sediment mobilisation and pollutant dispersal. In this study, we investigated the potential for handheld

  15. Neurosurgery contact handheld probe based on sapphire shaped crystal

    Science.gov (United States)

    Shikunova, I. A.; Stryukov, D. O.; Rossolenko, S. N.; Kiselev, A. M.; Kurlov, V. N.

    2017-01-01

    A handheld contact probe based on sapphire shaped crystal is developed for intraoperative spectrally-resolved optical diagnostics, laser coagulation and aspiration of malignant brain tissue. The technology was integrated into the neurosurgical workflow for intraoperative real-time identification and removing of invasive brain cancer.

  16. Octopus: embracing the energy efficiency of handheld multimedia computers

    NARCIS (Netherlands)

    Havinga, Paul J.M.; Smit, Gerardus Johannes Maria

    1999-01-01

    In the MOBY DICK project we develop and define the architecture of a new generation of mobile hand-held computers called Mobile Digital Companions. The Companions must meet several major requirements: high performance, energy efficient, a notion of Quality of Service (QoS), small size, and low

  17. Epilepsy Forewarning Using A Hand-Held Device

    Energy Technology Data Exchange (ETDEWEB)

    Hively, LM

    2005-02-21

    Over the last decade, ORNL has developed and patented a novel approach for forewarning of a large variety of machine and biomedical events. The present implementation uses desktop computers to analyze archival data. This report describes the next logical step in this effort, namely use of a hand-held device for the analysis.

  18. Imaging Emission Spectra with Handheld and Cellphone Cameras

    Science.gov (United States)

    Sitar, David

    2012-01-01

    As point-and-shoot digital camera technology advances it is becoming easier to image spectra in a laboratory setting on a shoestring budget and get immediate results. With this in mind, I wanted to test three cameras to see how their results would differ. Two undergraduate physics students and I used one handheld 7.1 megapixel (MP) digital Cannon…

  19. Human Handheld-Device Interaction : An Adaptive User Interface

    NARCIS (Netherlands)

    Fitrianie, S.

    2010-01-01

    The move to smaller, lighter and more powerful (mobile) handheld devices, whe-ther PDAs or smart-phones, looks like a trend that is building up speed. With numerous embedded technologies and wireless connectivity, the drift opens up unlimited opportunities in daily activities that are both more

  20. PRMS Data Warehousing Prototype

    Science.gov (United States)

    Guruvadoo, Eranna K.

    2002-01-01

    Project and Resource Management System (PRMS) is a web-based, mid-level management tool developed at KSC to provide a unified enterprise framework for Project and Mission management. The addition of a data warehouse as a strategic component to the PRMS is investigated through the analysis, design and implementation processes of a data warehouse prototype. As a proof of concept, a demonstration of the prototype with its OLAP's technology for multidimensional data analysis is made. The results of the data analysis and the design constraints are discussed. The prototype can be used to motivate interest and support for an operational data warehouse.

  1. Data for Users of Handheld Ion Mobility Spectrometers

    International Nuclear Information System (INIS)

    Keith A. Daum; Sandra L. Fox

    2008-01-01

    Chemical detection technology end-user surveys conducted by Idaho National Laboratory (INL) in 2005 and 2007 indicated that first responders believed manufacturers claims for instruments sometimes were not supported in field applications, and instruments sometimes did not meet their actual needs. Based on these findings, the Department of Homeland Security (DHS) asked INL to conduct a similar survey for handheld ion mobility spectrometers (IMS), which are used by a broad community of first responders as well as for other applications. To better access this broad community, the INL used the Center for Technology Commercialization, Inc. (CTC), Public Safety Technology Center (PSTC) to set up an online framework to gather information from users of handheld IMS units. This framework (Survey Monkey) was then used to perform an online Internet survey, augmented by e-mail prompts, to get information from first responders and personnel from various agencies about their direct experience with handheld IMS units. Overall, 478 individuals responded to the survey. Of these, 174 respondents actually owned a handheld IMS. Performance and satisfaction data from these 174 respondents are captured in this report. The survey identified the following observations: (1) The most common IMS unit used by respondents was the Advanced Portable Detector (APD 2000), followed by ChemRae, Sabre 4000, Sabre 2000, Draeger Multi IMS, Chemical Agent Monitor-2, Chemical Agent Monitor, Vapor Tracer, and Vapor Tracer 2. (2) The primary owners were HazMat teams (20%), fire services (14%), local police (12%), and sheriffs departments (9%). (3) IMS units are seldom used as part of an integrated system for detecting and identifying chemicals but instead are used independently. (4) Respondents are generally confused about the capabilities of their IMS unit. This is probably a result of lack of training. (5) Respondents who had no training or fewer than 8 hours were not satisfied with the overall operation

  2. Hand-held electronic data collection and procedure environment

    International Nuclear Information System (INIS)

    Kennedy, E.; Doniz, K.

    1996-01-01

    As part of a CANDU Owners Group project, AECL has developed a hand-held electronic data collection and procedure environment. Integral to this environment is the C omputerized Procedure Engine . The development of the CPE allows operators, maintainers, and technical support staff to execute virtually any type of station procedure on a general-purpose PC-compatible hand-held computer. There are several advantages to using the computerized procedures: less paper use and handling, reduction in human error, reduction in rework in the field, an increase in procedural compliance, and immediate availability of data to download to databases and plant information systems. The paper describes: the advantages of using computerized procedures, why early forms of computerized procedures were inadequate, the features that the C omputerized Procedure Engine o ffers to the user, the streamlined life cycle of a computerized procedure, and field experience. The paper concludes that computerized procedures are ready for pilot applications at stations. (author)

  3. Handheld computers in nursing education: PDA pilot project.

    Science.gov (United States)

    Koeniger-Donohue, Rebecca

    2008-02-01

    Interest in the use and application of handheld technology at undergraduate and graduate nursing programs across the country is growing rapidly. Personal digital assistants (PDAs) are often referred to as a "peripheral brain" because they can save time, decrease errors, and simplify information retrieval at the point of care. In addition, research results support the notion that PDAs enhance nursing clinical education and are an effective student learning resource. However, most nursing programs lack the full range of technological resources to implement and provide ongoing support for handheld technology use by faculty and students. This article describes a 9-month pilot project for the initial use of PDAs by novice faculty and students at Simmons College.

  4. Handheld Multi-Gas Meters Market Survey Report

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Gustavious [Brigham Young Univ., Provo, UT (United States); Wald-Hopkins, Mark David [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Obrey, Stephen J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Akhadov, Valida Dushdurova [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-23

    Handheld multi-gas meters (MGMs) are equipped with sensors to monitor oxygen (O2) levels and additional sensors to detect the presence of combustible or toxic gases in the environment. This report is limited to operational response-type MGMs that include at least four different sensors. These sensors can vary by type and by the chemical monitored. In real time, the sensors report the concentration of monitored gases in the atmosphere near the MGM. To provide emergency responders with information on handheld multi-gas meters, the System Assessment and Validation for Emergency Responders (SAVER) Program conducted a market survey. This market survey report is based on information gathered between November 2015 and February 2016 from vendors, Internet research, industry publications, an emergency responder focus group, and a government issued Request for Information (RFI) that was posted on the Federal Business Opportunities website.

  5. From prototype to product

    DEFF Research Database (Denmark)

    Andersen, Tariq Osman; Bansler, Jørgen P.; Kensing, Finn

    2017-01-01

    This paper delves into the challenges of engaging patients, clinicians and industry stakeholders in the participatory design of an mHealth platform for patient-clinician collaboration. It follows the process from the development of a research prototype to a commercial software product. In particu......This paper delves into the challenges of engaging patients, clinicians and industry stakeholders in the participatory design of an mHealth platform for patient-clinician collaboration. It follows the process from the development of a research prototype to a commercial software product....... In particular, we draw attention to four major challenges of (a) aligning the different concerns of patients and clinicians, (b) designing according to clinical accountability, (c) ensuring commercial interest, and (d) dealing with regulatory constraints when prototyping safety critical health Information...... Technology. Using four illustrative cases, we discuss what these challenges entail and the implications they pose to Participatory Design. We conclude the paper by presenting lessons learned....

  6. Gamma Knife

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Gamma Knife Gamma Knife® is a radiation therapy that uses computerized ... If you're scheduled for radiation therapy using Gamma Knife®, a treatment team consisting of a radiation ...

  7. Interactive topology optimization on hand-held devices

    DEFF Research Database (Denmark)

    Aage, Niels; Nobel-Jørgensen, Morten; Andreasen, Casper Schousboe

    2013-01-01

    This paper presents an interactive topology optimization application designed for hand-held devices running iOS or Android. The TopOpt app solves the 2D minimum compliance problem with interactive control of load and support positions as well as volume fraction. Thus, it is possible to change......OS devices from the Apple App Store, at Google Play for the Android platform, and a web-version can be run from www.topopt.dtu.dk....

  8. Characterisation of an AGATA symmetric prototype detector

    International Nuclear Information System (INIS)

    Nelson, L.; Dimmock, M.R.; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Nolan, P.J.; Lazarus, I.; Simpson, J.; Medina, P.; Santos, C.; Parisel, C.

    2007-01-01

    The Advanced GAmma Tracking Array (AGATA) symmetric prototype detector has been tested at University of Liverpool. A 137 Ce source, collimated to a 2 mm diameter, was scanned across the front face of the detector and data were acquired utilising digital electronics. Pulse shapes from a selection of well-defined photon interaction positions have been analysed to investigate the position sensitivity of the detector. Furthermore, the application of the electric field simulation software, Multi Geometry Simulation (MGS) to generate theoretical pulse shapes for AGATA detectors has been presented

  9. Characterisation of an AGATA symmetric prototype detector

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, L. [Oliver Lodge Laboratory, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom)]. E-mail: ln@ns.ph.liv.ac.uk; Dimmock, M.R. [Oliver Lodge Laboratory, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom)]. E-mail: mrd@ns.ph.liv.ac.uk; Boston, A.J. [Oliver Lodge Laboratory, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom)]. E-mail: ajb@ns.ph.liv.ac.uk; Boston, H.C. [Oliver Lodge Laboratory, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Cresswell, J.R. [Oliver Lodge Laboratory, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Nolan, P.J. [Oliver Lodge Laboratory, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Lazarus, I. [CCLRC Daresbury Laboratory, Daresbury, Warrington WA4 4AD (United Kingdom); Simpson, J. [CCLRC Daresbury Laboratory, Daresbury, Warrington WA4 4AD (United Kingdom); Medina, P. [Institut de Recherches Subatomiques, Strasbourg BP28 67037 (France); Santos, C. [Institut de Recherches Subatomiques, Strasbourg BP28 67037 (France); Parisel, C. [Institut de Recherches Subatomiques, Strasbourg BP28 67037 (France)

    2007-04-01

    The Advanced GAmma Tracking Array (AGATA) symmetric prototype detector has been tested at University of Liverpool. A {sup 137}Ce source, collimated to a 2 mm diameter, was scanned across the front face of the detector and data were acquired utilising digital electronics. Pulse shapes from a selection of well-defined photon interaction positions have been analysed to investigate the position sensitivity of the detector. Furthermore, the application of the electric field simulation software, Multi Geometry Simulation (MGS) to generate theoretical pulse shapes for AGATA detectors has been presented.

  10. PANDA Muon System Prototype

    Science.gov (United States)

    Abazov, Victor; Alexeev, Gennady; Alexeev, Maxim; Frolov, Vladimir; Golovanov, Georgy; Kutuzov, Sergey; Piskun, Alexei; Samartsev, Alexander; Tokmenin, Valeri; Verkheev, Alexander; Vertogradov, Leonid; Zhuravlev, Nikolai

    2018-04-01

    The PANDA Experiment will be one of the key experiments at the Facility for Antiproton and Ion Research (FAIR) which is under construction now in the territory of the GSI Helmholtz Centre for Heavy Ion Research in Darmstadt, Germany. PANDA is aimed to study hadron spectroscopy and various topics of the weak and strong forces. Muon System is chosen as the most suitable technology for detecting the muons. The Prototype of the PANDA Muon System is installed on the test beam line T9 at the Proton Synchrotron (PS) at CERN. Status of the PANDA Muon System prototype is presented with few preliminary results.

  11. Prototyping a Smart City

    DEFF Research Database (Denmark)

    Korsgaard, Henrik; Brynskov, Martin

    In this paper, we argue that by approaching the so-called Smart City as a design challenge, and an interaction design perspective, it is possible to both uncover existing challenges in the interplay between people, technology and society, as well as prototype possible futures. We present a case...... in which we exposed data about the online communication between the citizens and the municipality on a highly visible media facade, while at the same time prototyped a tool that enabled citizens to report ‘bugs’ within the city....

  12. PANDA Muon System Prototype

    Directory of Open Access Journals (Sweden)

    Abazov Victor

    2018-01-01

    Full Text Available The PANDA Experiment will be one of the key experiments at the Facility for Antiproton and Ion Research (FAIR which is under construction now in the territory of the GSI Helmholtz Centre for Heavy Ion Research in Darmstadt, Germany. PANDA is aimed to study hadron spectroscopy and various topics of the weak and strong forces. Muon System is chosen as the most suitable technology for detecting the muons. The Prototype of the PANDA Muon System is installed on the test beam line T9 at the Proton Synchrotron (PS at CERN. Status of the PANDA Muon System prototype is presented with few preliminary results.

  13. Carbonaceous species emitted from handheld two-stroke engines

    Science.gov (United States)

    Volckens, John; Olson, David A.; Hays, Michael D.

    Small, handheld two-stroke engines used for lawn and garden work (e.g., string trimmers, leaf blowers, etc.) can emit a variety of potentially toxic carbonaceous air pollutants. Yet, the emissions effluents from these machines go largely uncharacterized, constraining the proper development of human exposure estimates, emissions inventories, and climate and air quality models. This study samples and evaluates chemical pollutant emissions from the dynamometer testing of six small, handheld spark-ignition engines—model years 1998-2002. Four oil-gas blends were tested in each engine in duplicate. Emissions of carbon dioxide, carbon monoxide, and gas-phase hydrocarbons were predominant, and the PM emitted was organic matter primarily. An ANOVA model determined that engine type and control tier contributed significantly to emissions variations across all identified compound classes; whereas fuel blend was an insignificant variable accounting for engines were generally intermediate in magnitude compared with other gasoline-powered engines, numerous compounds traditionally viewed as motor vehicle markers are also present in small engine emissions in similar relative proportions. Given that small, handheld two-stroke engines used for lawn and garden work account for 5-10% of total US emissions of CO, CO 2, NO x, HC, and PM 2.5, source apportionment models and human exposure studies need to consider the effect of these small engines on ambient concentrations in air polluted environments.

  14. A smartphone controlled handheld microfluidic liquid handling system.

    Science.gov (United States)

    Li, Baichen; Li, Lin; Guan, Allan; Dong, Quan; Ruan, Kangcheng; Hu, Ronggui; Li, Zhenyu

    2014-10-21

    Microfluidics and lab-on-a-chip technologies have made it possible to manipulate small volume liquids with unprecedented resolution, automation and integration. However, most current microfluidic systems still rely on bulky off-chip infrastructures such as compressed pressure sources, syringe pumps and computers to achieve complex liquid manipulation functions. Here, we present a handheld automated microfluidic liquid handling system controlled by a smartphone, which is enabled by combining elastomeric on-chip valves and a compact pneumatic system. As a demonstration, we show that the system can automatically perform all the liquid handling steps of a bead-based HIV1 p24 sandwich immunoassay on a multi-layer PDMS chip without any human intervention. The footprint of the system is 6 × 10.5 × 16.5 cm, and the total weight is 829 g including battery. Powered by a 12.8 V 1500 mAh Li battery, the system consumed 2.2 W on average during the immunoassay and lasted for 8.7 h. This handheld microfluidic liquid handling platform is generally applicable to many biochemical and cell-based assays requiring complex liquid manipulation and sample preparation steps such as FISH, PCR, flow cytometry and nucleic acid sequencing. In particular, the integration of this technology with read-out biosensors may help enable the realization of the long-sought Tricorder-like handheld in vitro diagnostic (IVD) systems.

  15. Development and performance of a hand-held CZT detector for in-situ measurements at the emergency response

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Young Yong; Chung, Kun Ho; Kim, Chang Jong; Lee, Wan No; Choi, Geun Sik; Kang, Mun Ja [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Yoon, Jin [SI Detection Co. Ltd, Daejeon (Korea, Republic of)

    2016-06-15

    A hand-held detector for an emergency response was developed for nuclide identification and to estimate the information of the ambient dose rate in the scene of an accident as well as the radioactivity of the contaminants. To achieve this, the most suitable sensor was first selected as a cadmium zinc telluride (CZT) semiconductor and the signal processing unit from a sensor and the signal discrimination and storage unit were successfully manufactured on a printed circuit board. The performance of the developed signal processing unit was then evaluated to have an energy resolution of about 14 keV at 662 keV. The system control unit was also designed to operate the CZT detector, monitor the detector, battery, and interface status, and check and transmit the measured results of the ambient dose rate and radioactivity. In addition, a collimator, which can control the inner radius, and the airborne dust sampler, which consists of an air filter and charcoal filter, were developed and mounted to the developed CZT detector for the quick and efficient response of a nuclear accident. The hand-held CZT detector was developed to make the in-situ gamma-ray spectrometry and its performance was checked to have a good energy resolution. In addition, the collimator and the airborne dust sampler were developed and mounted to the developed CZT detector for a quick and efficient response to a nuclear accident.

  16. LEP vacuum chamber, prototype

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    Final prototype for the LEP vacuum chamber, see 8305170 for more details. Here we see the strips of the NEG pump, providing "distributed pumping". The strips are made from a Zr-Ti-Fe alloy. By passing an electrical current, they were heated to 700 deg C.

  17. Imagining the prototype

    NARCIS (Netherlands)

    Brouwer, C. E.; Bhomer, ten M.; Melkas, H.; Buur, J.

    2013-01-01

    This article reports on the analysis of a design session, employing conversation analysis. In the design session three experts and a designer discuss a prototype of a shirt, which has been developed with the input from these experts. The analysis focuses on the type of involvement of the

  18. MIND performance and prototyping

    International Nuclear Information System (INIS)

    Cervera-Villanueva, A.

    2008-01-01

    The performance of MIND (Magnetised Iron Neutrino Detector) at a neutrino factory has been revisited in a new analysis. In particular, the low neutrino energy region is studied, obtaining an efficiency plateau around 5 GeV for a background level below 10 -3 . A first look has been given into the detector optimisation and prototyping

  19. The prototype fast reactor

    International Nuclear Information System (INIS)

    Broomfield, A.M.

    1985-01-01

    The paper concerns the Prototype Fast Reactor (PFR), which is a liquid metal cooled fast reactor power station, situated at Dounreay, Scotland. The principal design features of a Fast Reactor and the PFR are given, along with key points of operating history, and health and safety features. The role of the PFR in the development programme for commercial reactors is discussed. (U.K.)

  20. AGS Booster prototype magnets

    Energy Technology Data Exchange (ETDEWEB)

    Danby, G.; Jackson, J.; Lee, Y.Y.; Phillips, R.; Brodowski, J.; Jablonski, E.; Keohane, G.; McDowell, B.; Rodger, E.

    1987-03-19

    Prototype magnets have been designed and constructed for two half cells of the AGS Booster. The lattice requires 2.4m long dipoles, each curved by 10/sup 0/. The multi-use Booster injector requires several very different standard magnet cycles, capable of instantaneous interchange using computer control from dc up to 10 Hz.

  1. AGS booster prototype magnets

    International Nuclear Information System (INIS)

    Danby, G.; Jackson, J.; Lee, Y.Y.; Phillips, R.; Brodowski, J.; Jablonski, E.; Keohane, G.; McDowell, B.; Rodger, E.

    1987-01-01

    Prototype magnets have been designed and constructed for two half cells of the AGS Booster. The lattice requires 2.4m long dipoles, each curved by 10 0 . The multi-use Booster injector requires several very different standard magnet cycles, capable of instantaneous interchange using computer control from dc up to 10 Hz

  2. Cockroft Walton accelerator prototype

    International Nuclear Information System (INIS)

    Hutapea, Sumihar.

    1976-01-01

    Prototype of a Cockroft Walton generator using ceramic and plastic capacitors is discussed. Compared to the previous generator, the construction and components are much more improved. Pralon is used for the high voltage insulation column and plastic is used as a dielectric material for the high voltage capacitor. Cockroft Walton generator is used as a high tension supply for an accelerator. (author)

  3. Prompt and Precise Prototyping

    Science.gov (United States)

    2003-01-01

    For Sanders Design International, Inc., of Wilton, New Hampshire, every passing second between the concept and realization of a product is essential to succeed in the rapid prototyping industry where amongst heavy competition, faster time-to-market means more business. To separate itself from its rivals, Sanders Design aligned with NASA's Marshall Space Flight Center to develop what it considers to be the most accurate rapid prototyping machine for fabrication of extremely precise tooling prototypes. The company's Rapid ToolMaker System has revolutionized production of high quality, small-to-medium sized prototype patterns and tooling molds with an exactness that surpasses that of computer numerically-controlled (CNC) machining devices. Created with funding and support from Marshall under a Small Business Innovation Research (SBIR) contract, the Rapid ToolMaker is a dual-use technology with applications in both commercial and military aerospace fields. The advanced technology provides cost savings in the design and manufacturing of automotive, electronic, and medical parts, as well as in other areas of consumer interest, such as jewelry and toys. For aerospace applications, the Rapid ToolMaker enables fabrication of high-quality turbine and compressor blades for jet engines on unmanned air vehicles, aircraft, and missiles.

  4. Surrogates-based prototyping

    NARCIS (Netherlands)

    Du Bois, E.; Horvath, I.

    2014-01-01

    The research is situated in the system development phase of interactive software products. In this detailed design phase, we found a need for fast testable prototyping to achieve qualitative change proposals on the system design. In this paper, we discuss a literature study on current software

  5. Z Andromedae: the prototype

    International Nuclear Information System (INIS)

    Viotti, R.; Giangrande, A.; Ricciardi, O.; Cassatella, A.

    1982-01-01

    Z And is considered as the ''prototype'' of the symbiotic stars. Besides its symbiotic spectrum, the star is also known for its characteristic light curve (and for the related spectral variations). Since many theoretical speculations on Z And and similar objects have been based on the luminosity and spectral variations of this star, the authors critically analyse the observational data concerning it. (Auth.)

  6. Prototype ATLAS straw tracker

    CERN Multimedia

    Laurent Guiraud

    1998-01-01

    This is an early prototype of the straw tracking device for the ATLAS detector at CERN. This detector will be part of the LHC project, scheduled to start operation in 2008. The straw tracker will consist of thousands of gas-filled straws, each containing a wire, allowing the tracks of particles to be followed.

  7. Courthouse Prototype Building

    Energy Technology Data Exchange (ETDEWEB)

    Malhotra, Mini [ORNL; New, Joshua Ryan [ORNL; Im, Piljae [ORNL

    2018-02-01

    As part of DOE's support of ANSI/ASHRAE/IES Standard 90.1 and IECC, researchers at Pacific Northwest National Laboratory (PNNL) apply a suite of prototype buildings covering 80% of the commercial building floor area in the U.S. for new construction. Efforts have started on expanding the prototype building suite to cover 90% of the commercial building floor area in the U.S., by developing prototype models for additional building types including place of worship, public order and safety, public assembly. Courthouse is courthouse is a sub-category under the “Public Order and Safety" building type category; other sub-categories include police station, fire station, and jail, reformatory or penitentiary.ORNL used building design guides, databases, and documented courthouse projects, supplemented by personal communication with courthouse facility planning and design experts, to systematically conduct research on the courthouse building and system characteristics. This report documents the research conducted for the courthouse building type and proposes building and system characteristics for developing a prototype building energy model to be included in the Commercial Building Prototype Model suite. According to the 2012 CBECS, courthouses occupy a total of 436 million sqft of floor space or 0.5% of the total floor space in all commercial buildings in the US, next to fast food (0.35%), grocery store or food market (0.88%), and restaurant or cafeteria (1.2%) building types currently included in the Commercial Prototype Building Model suite. Considering aggregated average, courthouse falls among the larger with a mean floor area of 69,400 sqft smaller fuel consumption intensity building types and an average of 94.7 kBtu/sqft compared to 77.8 kBtu/sqft for office and 80 kBtu/sqft for all commercial buildings.Courthouses range in size from 1000 sqft to over a million square foot building gross square feet and 1 courtroom to over 100 courtrooms. Small courthouses

  8. Group differences in physician responses to handheld presentation of clinical evidence: a verbal protocol analysis

    Directory of Open Access Journals (Sweden)

    Pavlovic Nada J

    2007-07-01

    Full Text Available Abstract Background To identify individual differences in physicians' needs for the presentation of evidence resources and preferences for mobile devices. Methods Within-groups analysis of responses to semi-structured interviews. Interviews consisted of using prototypes in response to task-based scenarios. The prototypes were implemented on two different form factors: a tablet style PC and a pocketPC. Participants were from three user groups: general internists, family physicians and medicine residents, and from two different settings: urban and semi-urban. Verbal protocol analysis, which consists of coding utterances, was conducted on the transcripts of the testing sessions. Statistical relationships were investigated between staff physicians' and residents' background variables, self-reported experiences with the interfaces, and verbal code frequencies. Results 47 physicians were recruited from general internal medicine, family practice clinics and a residency training program. The mean age of participants was 42.6 years. Physician specialty had a greater effect on device and information-presentation preferences than gender, age, setting or previous technical experience. Family physicians preferred the screen size of the tablet computer and were less concerned about its portability. Residents liked the screen size of the tablet, but preferred the portability of the pocketPC. Internists liked the portability of the pocketPC, but saw less advantage to the large screen of the tablet computer (F[2,44] = 4.94, p = .012. Conclusion Different types of physicians have different needs and preferences for evidence-based resources and handheld devices. This study shows how user testing can be incorporated into the process of design to inform group-based customization.

  9. Introducing handheld computing into a residency program: preliminary results from qualitative and quantitative inquiry.

    OpenAIRE

    Manning, B.; Gadd, C. S.

    2001-01-01

    Although published reports describe specific handheld computer applications in medical training, we know very little yet about how, and how well, handheld computing fits into the spectrum of information resources available for patient care and physician training. This paper reports preliminary quantitative and qualitative results from an evaluation study designed to track changes in computer usage patterns and computer-related attitudes before and after introduction of handheld computing. Pre...

  10. Handheld, Broadband Electromagnetic UXO Sensor: Cost & Performance Report

    National Research Council Canada - National Science Library

    Won, I. J; SanFilipo, Bill; Oren, Alex

    2006-01-01

    The broadband electromagnetic sensor improvement and demonstration undertaken in this project took the prototype GEM-3 and evolved it into an operational sensor with increased bandwidth and dynamic...

  11. Database Replication Prototype

    OpenAIRE

    Vandewall, R.

    2000-01-01

    This report describes the design of a Replication Framework that facilitates the implementation and com-parison of database replication techniques. Furthermore, it discusses the implementation of a Database Replication Prototype and compares the performance measurements of two replication techniques based on the Atomic Broadcast communication primitive: pessimistic active replication and optimistic active replication. The main contributions of this report can be split into four parts....

  12. Brachial Plexus Blocker Prototype

    OpenAIRE

    Stéphanie Coelho Monteiro

    2017-01-01

    Although the area of surgical simulation has been the subject of study in recent years, it is still necessary to develop artificial experimental models with a perspective to dismiss the use of biological models. Since this makes the simulators more real, transferring the environment of the health professional to a physical or virtual reality, an anesthetic prototype has been developed, where the motor response is replicated when the brachial plexus is subjected to a proximal nervous stimulus....

  13. A hand-held robotic device for peripheral intravenous catheterization.

    Science.gov (United States)

    Cheng, Zhuoqi; Davies, Brian L; Caldwell, Darwin G; Barresi, Giacinto; Xu, Qinqi; Mattos, Leonardo S

    2017-12-01

    Intravenous catheterization is frequently required for numerous medical treatments. However, this process is characterized by a high failure rate, especially when performed on difficult patients such as newborns and infants. Very young patients have small veins, and that increases the chances of accidentally puncturing the catheterization needle directly through them. In this article, we present the design, development and experimental evaluation of a novel hand-held robotic device for improving the process of peripheral intravenous catheterization by facilitating the needle insertion procedure. To our knowledge, this design is the first hand-held robotic device for assisting in the catheterization insertion task. Compared to the other available technologies, it has several unique advantages such as being compact, low-cost and able to reliably detect venipuncture. The system is equipped with an electrical impedance sensor at the tip of the catheterization needle, which provides real-time measurements used to supervise and control the catheter insertion process. This allows the robotic system to precisely position the needle within the lumen of the target vein, leading to enhanced catheterization success rate. Experiments conducted to evaluate the device demonstrated that it is also effective to deskill the task. Naïve subjects achieved an average catheterization success rate of 88% on a 1.5 mm phantom vessel with the robotic device versus 12% with the traditional unassisted system. The results of this work prove the feasibility of a hand-held assistive robotic device for intravenous catheterization and show that such device has the potential to greatly improve the success rate of these difficult operations.

  14. Prototyping real-time systems

    OpenAIRE

    Clynch, Gary

    1994-01-01

    The traditional software development paradigm, the waterfall life cycle model, is defective when used for developing real-time systems. This thesis puts forward an executable prototyping approach for the development of real-time systems. A prototyping system is proposed which uses ESML (Extended Systems Modelling Language) as a prototype specification language. The prototyping system advocates the translation of non-executable ESML specifications into executable LOOPN (Language of Object ...

  15. Adaptive RF front-ends for hand-held applications

    CERN Document Server

    van Bezooijen, Andre; van Roermund, Arthur

    2010-01-01

    The RF front-end - antenna combination is a vital part of a mobile phone because its performance is very relevant to the link quality between hand-set and cellular network base-stations. The RF front-end performance suffers from changes in operating environment, like hand-effects, that are often unpredictable. ""Adaptive RF Front-Ends for Hand-Held Applications"" presents an analysis on the impact of fluctuating environmental parameters. In order to overcome undesired behavior two different adaptive control methods are treated that make RF frond-ends more resilient: adaptive impedance control,

  16. Absorption Related to Hand-Held Devices in Data Mode

    DEFF Research Database (Denmark)

    Andersen, Jørgen Bach; Nielsen, Jesper Ødum; Pedersen, Gert F.

    2016-01-01

    The human body has an influence on the radiation from handheld devices like smartphones, tablets and laptops, part of the energy is absorbed and the spatial distribution of the radiated part is modified. Previous studies of whole body absorp- tion have mainly been numerical or related to talk mode....... In the present paper an experimental study involving four volunteers and three different devices is performed from 0.5 to 3 GHz. The devices are a laptop, a tablet, and a smartphone all held in the lap. The 3D distribution of radiation is measured. Comparing the integrated power in the case of a person present...

  17. Development of dual sensor hand-held detector

    Science.gov (United States)

    Sezgin, Mehmet

    2010-04-01

    In this paper hand-held dual sensor detector development requirements are considered dedicated to buried object detection. Design characteristics of such a system are categorized and listed. Hardware and software structures, ergonomics, user interface, environmental and EMC/EMI tests to be applied and performance test issues are studied. Main properties of the developed system (SEZER) are presented, which contains Metal Detector (MD) and Ground Penetrating Radar (GPR). The realized system has ergonomic structure and can detect both metallic and non-metallic buried objects. Moreover classification of target is possible if it was defined to the signal processing software in learning phase.

  18. Fast, cheap and in control: spectral imaging with handheld devices

    Science.gov (United States)

    Gooding, Edward A.; Deutsch, Erik R.; Huehnerhoff, Joseph; Hajian, Arsen R.

    2017-05-01

    Remote sensing has moved out of the laboratory and into the real world. Instruments using reflection or Raman imaging modalities become faster, cheaper and more powerful annually. Enabling technologies include virtual slit spectrometer design, high power multimode diode lasers, fast open-loop scanning systems, low-noise IR-sensitive array detectors and low-cost computers with touchscreen interfaces. High-volume manufacturing assembles these components into inexpensive portable or handheld devices that make possible sophisticated decision-making based on robust data analytics. Examples include threat, hazmat and narcotics detection; remote gas sensing; biophotonic screening; environmental remediation and a host of other applications.

  19. MITRE sensor layer prototype

    Science.gov (United States)

    Duff, Francis; McGarry, Donald; Zasada, David; Foote, Scott

    2009-05-01

    The MITRE Sensor Layer Prototype is an initial design effort to enable every sensor to help create new capabilities through collaborative data sharing. By making both upstream (raw) and downstream (processed) sensor data visible, users can access the specific level, type, and quantities of data needed to create new data products that were never anticipated by the original designers of the individual sensors. The major characteristic that sets sensor data services apart from typical enterprise services is the volume (on the order of multiple terabytes) of raw data that can be generated by most sensors. Traditional tightly coupled processing approaches extract pre-determined information from the incoming raw sensor data, format it, and send it to predetermined users. The community is rapidly reaching the conclusion that tightly coupled sensor processing loses too much potentially critical information.1 Hence upstream (raw and partially processed) data must be extracted, rapidly archived, and advertised to the enterprise for unanticipated uses. The authors believe layered sensing net-centric integration can be achieved through a standardize-encapsulate-syndicateaggregate- manipulate-process paradigm. The Sensor Layer Prototype's technical approach focuses on implementing this proof of concept framework to make sensor data visible, accessible and useful to the enterprise. To achieve this, a "raw" data tap between physical transducers associated with sensor arrays and the embedded sensor signal processing hardware and software has been exploited. Second, we encapsulate and expose both raw and partially processed data to the enterprise within the context of a service-oriented architecture. Third, we advertise the presence of multiple types, and multiple layers of data through geographic-enabled Really Simple Syndication (GeoRSS) services. These GeoRSS feeds are aggregated, manipulated, and filtered by a feed aggregator. After filtering these feeds to bring just the type

  20. A prototype analysis of vengeance

    NARCIS (Netherlands)

    Elshout, Maartje; Nelissen, Rob; van Beest, Ilja

    2015-01-01

    The authors examined the concept of vengeance from a prototype perspective. In 6 studies, the prototype structure of vengeance was mapped. Sixty-nine features of vengeance were identified (Study 1), and rated on centrality (Study 2). Further studies confirmed the prototype structure. Compared to

  1. Hand-held, mechanically cooled, radiation detection system for gamma-ray spectroscopy

    Science.gov (United States)

    Burks, Morgan Thomas; Eckels, Joel Del

    2010-06-08

    In one embodiment, a radiation detection system is provided including a radiation detector and a first enclosure encapsulating the radiation detector, the first enclosure including a low-emissivity infra-red (IR) reflective coating used to thermally isolate the radiation detector. Additionally, a second enclosure encapsulating the first enclosure is included, the first enclosure being suspension mounted to the second enclosure. Further, a cooler capable of cooling the radiation detector is included. Still yet, a first cooling interface positioned on the second enclosure is included for coupling the cooler and the first enclosure. Furthermore, a second cooling interface positioned on the second enclosure and capable of coupling the first enclosure to a cooler separate from the radiation detection system is included. Other embodiments are also presented.

  2. Measuring thyroid uptake with hand-held radiation monitors

    International Nuclear Information System (INIS)

    Deschamps, M.

    1987-04-01

    With the use of Iodine 123, 125 and 131 and some compounds of Technetium-99 m, a fraction of the isotopes can be trapped in the thyroid of the technicians. We used the hand-held radiation contamination or survey meters of the nine (9) Nuclear medicine departments we visited to see if they were adequate for the evaluation of thyroid uptake of the users. Measurements on a neck-phanton helped us to determine a minimum detectable activity for each isotope. We were then able to check if the measurements of investigations and action levels were possible. None of the hand-held radiation monitors are completely satisfactory for the measure of thyroid uptake of the user. We discuss a class of equipment capable of measuring radiation emissions at the investigation level. Measurement at the action level is possible with meters having scintillation or proportional probes but none of them permits the discrimination in energy required for a quantitative evaluation of the radioisotopes used

  3. Elbow joint position sense after neuromuscular training with handheld vibration.

    Science.gov (United States)

    Tripp, Brady L; Faust, Donald; Jacobs, Patrick

    2009-01-01

    Clinicians use neuromuscular control exercises to enhance joint position sense (JPS); however, because standardizing such exercises is difficult, validations of their use are limited. To evaluate the acute effects of a neuromuscular training exercise with a handheld vibrating dumbbell on elbow JPS acuity. Crossover study. University athletic training research laboratory. Thirty-one healthy, college-aged volunteers (16 men, 15 women, age = 23 + or - 3 years, height = 173 + or - 8 cm, mass = 76 + or - 14 kg). We measured and trained elbow JPS using an electromagnetic tracking device that provided auditory and visual biofeedback. For JPS testing, participants held a dumbbell and actively identified the target elbow flexion angle (90 degrees ) using the software-generated biofeedback, followed by 3 repositioning trials without feedback. Each neuromuscular training protocol included 3 exercises during which participants held a 2.55-kg dumbbell vibrating at 15, 5, or 0 Hz and used software-generated biofeedback to locate and maintain the target elbow flexion angle for 15 seconds. We calculated absolute (accuracy) and variable (variability) errors using the differences between target and reproduced angles. Training protocols using 15-Hz vibration enhanced accuracy and decreased variability of elbow JPS (P or = .200). Our results suggest these neuromuscular control exercises, which included low-magnitude, low-frequency handheld vibration, may enhance elbow JPS. Future researchers should examine vibration of various durations and frequencies, should include injured participants and functional multijoint and multiplanar measures, and should examine long-term effects of training protocols on JPS and injury.

  4. An Investigation of Game-Embedded Handheld Devices to Enhance English Learning

    Science.gov (United States)

    Hung, Hui-Chun; Young, Shelley Shwu-Ching

    2015-01-01

    This study proposed and implemented a system combining the advantages of both educational games and wireless handheld technology to promote the interactive English learning in the classroom setting. An interactive English vocabulary acquisition board game was designed with the system being implemented on handheld devices. Thirty sixth-grade…

  5. My-Mini-Pet: A Handheld Pet-Nurturing Game to Engage Students in Arithmetic Practices

    Science.gov (United States)

    Liao, C. C. Y.; Chen, Z-H.; Cheng, H. N. H.; Chen, F-C.; Chan, T-W.

    2011-01-01

    In the last decade, more and more games have been developed for handheld devices. Furthermore, the popularity of handheld devices and increase of wireless computing can be taken advantage of to provide students with more learning opportunities. Games also could bring promising benefits--specifically, motivating students to learn/play, sustaining…

  6. 75 FR 27504 - Substantial Product Hazard List: Hand-Held Hair Dryers

    Science.gov (United States)

    2010-05-17

    ... immersion during their use. Section 15(a) of the CPSA defines ``substantial product hazard'' to include, a....'' Hand-held hair dryers routinely contain open-coil heating elements that are, in essence, uninsulated..., bathtub, or lavatory). The proposed rule would define ``hand-held hair dryer'' as ``an electrical...

  7. 40 CFR 90.129 - Fuel tank permeation from handheld engines and equipment.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Fuel tank permeation from handheld... KILOWATTS Emission Standards and Certification Provisions § 90.129 Fuel tank permeation from handheld... equipment with respect to fuel tanks. For the purposes of this section, fuel tanks do not include fuel caps...

  8. The impact of legislation in Ireland on handheld mobile phone use by drivers.

    LENUS (Irish Health Repository)

    O'Meara, M

    2008-01-01

    Under the Road Traffic Act, 2006 handheld mobile phone use whilst driving is an offence liable to a fine and penalty points. The aim of this study was to determine whether there has been a change in driver behaviour following the introduction of this legislation. This study found that 2.3% of drivers were still using a handheld mobile phone.

  9. Evaluation of an enclosed ultraviolet-C radiation device for decontamination of mobile handheld devices.

    Science.gov (United States)

    Mathew, J Itty; Cadnum, Jennifer L; Sankar, Thriveen; Jencson, Annette L; Kundrapu, Sirisha; Donskey, Curtis J

    2016-06-01

    Mobile handheld devices used in health care settings may become contaminated with health care-associated pathogens. We demonstrated that an enclosed ultraviolet-C radiation device was effective in rapidly reducing methicillin-resistant Staphylococcus aureus, and with longer exposure times, Clostridium difficile spores, on glass slides and reducing contamination on in-use mobile handheld devices. Published by Elsevier Inc.

  10. OPAL Jet Chamber Prototype

    CERN Multimedia

    OPAL was one of the four experiments installed at the LEP particle accelerator from 1989 - 2000. OPAL's central tracking system consists of (in order of increasing radius) a silicon microvertex detector, a vertex detector, a jet chamber, and z-chambers. All the tracking detectors work by observing the ionization of atoms by charged particles passing by: when the atoms are ionized, electrons are knocked out of their atomic orbitals, and are then able to move freely in the detector. These ionization electrons are detected in the dirfferent parts of the tracking system. This piece is a prototype of the jet chambers

  11. Prototyping Augmented Reality

    CERN Document Server

    Mullen, Tony

    2011-01-01

    Learn to create augmented reality apps using Processing open-source programming language Augmented reality (AR) is used all over, and you may not even realize it. Smartphones overlay data onto live camera views to show homes for sale, restaurants, or historical sites. American football broadcasts use AR to show the invisible first-down line on the field to TV viewers. Nike and Budweiser, among others, have used AR in ads. Now, you can learn to create AR prototypes using 3D data, Processing open-source programming language, and other languages. This unique book is an easy-to-follow guide on how

  12. Nightshade Prototype Experiments (Silverleaf)

    Energy Technology Data Exchange (ETDEWEB)

    Danielson, Jeremy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Bauer, Amy L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-12-23

    The Red Sage campaign is a series of subcritical dynamic plutonium experiments designed to measure ejecta. Nightshade, the first experiments in Red Sage scheduled for fiscal year 2019, will measure the amount of ejecta emission into vacuum from a double-­shocked plutonium surface. To address the major technical risks in Nightshade, a Level 2 milestone was developed for fiscal year 2016. Silverleaf, a series of four experiments, was executed at the Los Alamos National Laboratory in July and August 2016 to demonstrate a prototype of the Nightshade package and to satisfy this Level 2 milestone. This report is documentation that Red Sage Level 2 milestone requirements were successfully met.

  13. Extra-light gamma-ray imager for safeguards and homeland security

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, Oleg P.; Semin, Ilya A.; Potapov, Victor N.; Stepanov, Vyacheslav E. [National Research Centre Kurchatov Institute, Moscow, 123182, (Russian Federation)

    2015-07-01

    Gamma-ray imaging is the most important way to identify unknown gamma-ray emitting objects in decommissioning, security, overcoming accidents. Over the past two decades a system for producing of gamma images in these conditions became more or less portable devices. But in recent years these systems have become the hand-held devices. This is very important, especially in emergency situations, and measurements for safety reasons. We describe the first integrated hand-held instrument for emergency and security applications. The device is based on the coded aperture image formation, position sensitive gamma-ray (X-ray) detector Medipix2 (detectors produces by X-ray Imaging Europe) and tablet computer. The development was aimed at creating a very low weight system with high angular resolution. We present some sample gamma-ray images by camera. Main estimated parameters of the system are the following. The field of view video channel ∼ 490 deg. The field of view gamma channel ∼ 300 deg. The sensitivity of the system with a hexagonal mask for the source of Cs-137 (Eg = 662 keV), is in units of dose D ∼ 100 mR. This option is less then order of magnitude worse than for the heavy, non-hand-held systems (e.g., gamma-camera Cartogam, by Canberra.) The angular resolution of the gamma channel for the sources of Cs-137 (Eg = 662 keV) is about 1.20 deg. (authors)

  14. DataCollection Prototyping

    CERN Multimedia

    Beck, H.P.

    DataCollection is a subsystem of the Trigger, DAQ & DCS project responsible for the movement of event data from the ROS to the High Level Triggers. This includes data from Regions of Interest (RoIs) for Level 2, building complete events for the Event Filter and finally transferring accepted events to Mass Storage. It also handles passing the LVL1 RoI pointers and the allocation of Level 2 processors and load balancing of Event Building. During the last 18 months DataCollection has developed a common architecture for the hardware and software required. This involved a radical redesign integrating ideas from separate parts of earlier TDAQ work. An important milestone for this work, now achieved, has been to demonstrate this subsystem in the so-called Phase 2A Integrated Prototype. This prototype comprises the various TDAQ hardware and software components (ROSs, LVL2, etc.) under the control of the TDAQ Online software. The basic functionality has been demonstrated on small testbeds (~8-10 processing nodes)...

  15. OMS FDIR: Initial prototyping

    Science.gov (United States)

    Taylor, Eric W.; Hanson, Matthew A.

    1990-01-01

    The Space Station Freedom Program (SSFP) Operations Management System (OMS) will automate major management functions which coordinate the operations of onboard systems, elements and payloads. The objectives of OMS are to improve safety, reliability and productivity while reducing maintenance and operations cost. This will be accomplished by using advanced automation techniques to automate much of the activity currently performed by the flight crew and ground personnel. OMS requirements have been organized into five task groups: (1) Planning, Execution and Replanning; (2) Data Gathering, Preprocessing and Storage; (3) Testing and Training; (4) Resource Management; and (5) Caution and Warning and Fault Management for onboard subsystems. The scope of this prototyping effort falls within the Fault Management requirements group. The prototyping will be performed in two phases. Phase 1 is the development of an onboard communications network fault detection, isolation, and reconfiguration (FDIR) system. Phase 2 will incorporate global FDIR for onboard systems. Research into the applicability of expert systems, object-oriented programming, fuzzy sets, neural networks and other advanced techniques will be conducted. The goals and technical approach for this new SSFP research project are discussed here.

  16. Live Piloting and Prototyping

    Directory of Open Access Journals (Sweden)

    Francesca Rizzo

    2013-07-01

    Full Text Available This paper presents current trends in service design research concerning large scale projects aimed at generating changes at a local scale. The strategy adopted to achieve this, is to co-design solutions including future users in the development process, prototyping and testing system of products and services before their actual implementation. On the basis of experience achieved in the European Project Life 2.0, this paper discusses which methods and competencies are applied in the development of these projects, eliciting the lessons learnt especially from the piloting phase in which the participatory design (PD approach plays a major role. In the first part, the topic is introduced jointly with the theoretical background where the user center design and participatory design methods are presented; then the Life 2.0 project development is described; finally the experience is discussed from a service design perspective, eliciting guidelines for piloting and prototyping services in a real context of use. The paper concludes reflecting on the designers’ role and competencies needed in this process.

  17. Gamma astronomy

    International Nuclear Information System (INIS)

    Cesarsky, C.; Cesarsky, J.P.

    1986-01-01

    This article overviews the gamma astronomy research. Sources already observed, and what causes to give to them; the galactic radiation and its interpretation; techniques already used and current projects [fr

  18. Gamma Spectroscopy

    NARCIS (Netherlands)

    Niemantsverdriet, J.W.; Butz, Tilman; Ertl, G.; Knözinger, H.; Schüth, F.

    2008-01-01

    No abstract. The sections in this article are 1 Introduction 2 Mössbauer Spectroscopy 3 Time-Differential Perturbed Angular Correlations (TDPAC) 4 Conclusions and Outlook Keywords: Mössbauer spectroscopy; gamma spectroscopy; perturbed angular correlation; TDPAC

  19. Prototypes as Platforms for Participation

    DEFF Research Database (Denmark)

    Horst, Willem

    developers, and design it accordingly. Designing a flexible prototype in combination with supportive tools to be used by both interaction designers and non-designers during development is introduced as a way to open up the prototyping process to these users. Furthermore I demonstrate how such a flexible...... on prototyping, by bringing to attention that the prototype itself is an object of design, with its users and use context, which deserves further attention. Moreover, in this work I present concrete tools and methods that can be used by interaction designers in practice. As such this work addresses both......The development of interactive products in industry is an activity involving different disciplines – such as different kinds of designers, engineers, marketers and managers – in which prototypes play an important role. On the one hand, prototypes can be powerful boundary objects and an effective...

  20. Prototype Stilbene Neutron Collar

    Energy Technology Data Exchange (ETDEWEB)

    Prasad, M. K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Shumaker, D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Snyderman, N. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Verbeke, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wong, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-10-26

    A neutron collar using stilbene organic scintillator cells for fast neutron counting is described for the assay of fresh low enriched uranium (LEU) fuel assemblies. The prototype stilbene collar has a form factor similar to standard He-3 based collars and uses an AmLi interrogation neutron source. This report describes the simulation of list mode neutron correlation data on various fuel assemblies including some with neutron absorbers (burnable Gd poisons). Calibration curves (doubles vs 235U linear mass density) are presented for both thermal and fast (with Cd lining) modes of operation. It is shown that the stilbene collar meets or exceeds the current capabilities of He-3 based neutron collars. A self-consistent assay methodology, uniquely suited to the stilbene collar, using triples is described which complements traditional assay based on doubles calibration curves.

  1. Brachial Plexus Blocker Prototype

    Directory of Open Access Journals (Sweden)

    Stéphanie Coelho Monteiro

    2017-08-01

    Full Text Available Although the area of surgical simulation has been the subject of study in recent years, it is still necessary to develop artificial experimental models with a perspective to dismiss the use of biological models. Since this makes the simulators more real, transferring the environment of the health professional to a physical or virtual reality, an anesthetic prototype has been developed, where the motor response is replicated when the brachial plexus is subjected to a proximal nervous stimulus. Using action-research techniques, with this simulator it was possible to validate that the human nerve response can be replicated, which will aid the training of health professionals, reducing possible risks in a surgical environment.

  2. Computer-assisted trauma care prototype.

    Science.gov (United States)

    Holzman, T G; Griffith, A; Hunter, W G; Allen, T; Simpson, R J

    1995-01-01

    accurately used in urban, rural, and military field settings. his demonstration will focus on the user interfaces for the hand-held computer device included in TCIMS, the Field Medic Associate (FMA). The FMA prototype is a ruggedized, water-resistant personal computer, weighing approximately 5 lbs. It has an LCD graphical user interface display for patient record input and output, pen-based and audio input, audio output, and wireless communications capabilities. Automatic recording and dynamic, graphical display of time-stamped trends in patient vital signs will be simulated during the demonstration. Means for accessing existing patient record information (e.g., allergies to particular medications) and updating the record with the nature of the injury, its cause, and the treatments that were administered will be shown. These will include use of an electronic pen to mark up anatoglyphs (standard drawings of human body appearing on computer screen) to show where injuries occurred and where treatments were applied, and to input textual descriptions of the nature of the injury, its cause, what treatments were administered, etc. Computer recognition of handwritten inputs will be shown. Likewise, voice annotation and audio playback of patient record information by medics and hospital personnel will be illustrated. These latter technologies free the care providers' hands to treat the patient; they can therefore provide inputs to the patient record while information is fresh in their minds. The audio playback option allows hospital personnel to select more detailed voice annotations of specific portions of the patient record by simply touching the electronic pen to a particular place where an electronic pen marking was made by a medic in the field and then listening to the medic's corresponding audio commentary. Finally, the FMA's means for assisting the medic in simultaneously managing several injured patients will be shown. (abstract truncated)

  3. Performance of prototype segmented CdZnTe arrays

    International Nuclear Information System (INIS)

    Parsons, A.; Palmer, D.M.; Kurczynski, P.; Barbier, L.; Barthelmy, S.; Bartlett, L.; Gehrels, N.; Krizmanic, J.; Stahle, C.M.; Tueller, J.; Teegarden, B.

    1998-01-01

    The Burst and All Sky Imaging Survey (BASIS) is a proposed mission to provide ∼3 arc second locations of approximately 90 Gamma-Ray Bursts (GRBs) per year. The BASIS coded aperture imaging system requires a segmented detector plane able to detect the interaction position of (10--150 keV) photons to less than 100 microm. To develop prototype detector arrays with such fine position resolution the authors have fabricated many 15 mm x 15 mm x 2 mm 100 microm pitch CdZnTe strip detectors. They have assembled these fine pitch CdZnTe strip detectors into prototype 2 x 2 and 6 x 6 element arrays read out by ASIC electronics. The assembly and electronics readout of the 6 x 6 flight prototype array will be discussed, and preliminary data illustrating the uniformity and efficiency of the array will be presented

  4. Performance of a prototype water Cherenkov detector for LHAASO project

    International Nuclear Information System (INIS)

    An, Q.; Bai, Y.X.; Bi, X.J.; Cao, Z.; Cao, Zhe; Chang, J.F.; Chen, G.; Chen, L.H.; Chen, M.J.; Chen, T.L.; Chen, Y.T.; Cui, S.W.; Dai, B.Z.; Danzengluobu; Feng, C.F.; Gao, B.; Gu, M.H.; Hao, X.J.; He, H.H.; Hu, H.B.

    2011-01-01

    A large high-altitude air shower observatory is to be built at Yang-Ba-Jing, Tibet, China. One of its main purposes is to survey the northern sky for very-high-energy (above 100 GeV) gamma ray sources via its ground-based water Cherenkov detector array. To gain full knowledge of water Cherenkov technique in detecting air showers, a prototype water Cherenkov detector is built at the Institute of High Energy Physics, Beijing. The performance of the prototype water Cherenkov detector is studied by measuring its response to cosmic muons. The results are compared with those from a full Monte Carlo simulation to provide a series of information regarding the prototype detector in guiding electronics design and detector optimization.

  5. A sensitive, handheld vapor sensor based on microcantilevers

    Science.gov (United States)

    Pinnaduwage, L. A.; Hedden, D. L.; Gehl, A.; Boiadjiev, V. I.; Hawk, J. E.; Farahi, R. H.; Thundat, T.; Houser, E. J.; Stepnowski, S.; McGill, R. A.; Deel, L.; Lareau, R. T.

    2004-11-01

    We report the development of a handheld sensor based on piezoresistive microcantilevers that does not depend on optical detection, yet has high detection sensitivity. The sensor is able to detect vapors from the plastic explosives pentaerythritol tetranitrate and hexahydro-1,3,5-triazine at levels below 10 parts per trillion within few seconds of exposure under ambient conditions. A differential measurement technique has yielded a rugged sensor that is unaffected by vibration and is able to function as a "sniffer." The microelectromechanical system sensor design allows for the incorporation of hundreds of microcantilevers with suitable coatings in order to achieve sufficient selectivity in the future, and thus could provide an inexpensive, unique platform for the detection of chemical, biological, and explosive materials.

  6. Handheld Micromanipulator for Robot-Assisted Stapes Footplate Surgery

    Science.gov (United States)

    Grande, Gonzalo Montes; Knisely, Anna J.; Becker, Brian C.; Yang, Sungwook; Hirsch, Barry E.; Riviere, Cameron N.

    2012-01-01

    Stapes footplate surgery is complex and delicate. This surgery is carried out in the middle ear to improve hearing. High accuracy is required to avoid critical tissues and structures near the surgical worksite. By suppressing the surgeon’s tremor during the operation, accuracy can be improved. In this paper, a fully handheld active micromanipulator known as Micron is evaluated for its feasibility for this delicate operation. An ergonomic handle, a custom tip, and a brace attachment were designed for stapes footplate surgery and tested in a fenestration task through a fixed speculum. Accuracy was measured during simulated surgery in two different scenarios: Micron off (unaided) and Micron on (aided), both with image guidance. Preliminary results show that Micron significantly reduces the mean position error and the mean duration of time spent in specified dangerous zones. PMID:23366167

  7. Comparative Geometrical Investigations of Hand-Held Scanning Systems

    Science.gov (United States)

    Kersten, T. P.; Przybilla, H.-J.; Lindstaedt, M.; Tschirschwitz, F.; Misgaiski-Hass, M.

    2016-06-01

    An increasing number of hand-held scanning systems by different manufacturers are becoming available on the market. However, their geometrical performance is little-known to many users. Therefore the Laboratory for Photogrammetry & Laser Scanning of the HafenCity University Hamburg has carried out geometrical accuracy tests with the following systems in co-operation with the Bochum University of Applied Sciences (Laboratory for Photogrammetry) as well as the Humboldt University in Berlin (Institute for Computer Science): DOTProduct DPI-7, Artec Spider, Mantis Vision F5 SR, Kinect v1 + v2, Structure Sensor and Google's Project Tango. In the framework of these comparative investigations geometrically stable reference bodies were used. The appropriate reference data were acquired by measurement with two structured light projection systems (AICON smartSCAN and GOM ATOS I 2M). The comprehensive test results of the different test scenarios are presented and critically discussed in this contribution.

  8. COMPARATIVE GEOMETRICAL INVESTIGATIONS OF HAND-HELD SCANNING SYSTEMS

    Directory of Open Access Journals (Sweden)

    T. P. Kersten

    2016-06-01

    Full Text Available An increasing number of hand-held scanning systems by different manufacturers are becoming available on the market. However, their geometrical performance is little-known to many users. Therefore the Laboratory for Photogrammetry & Laser Scanning of the HafenCity University Hamburg has carried out geometrical accuracy tests with the following systems in co-operation with the Bochum University of Applied Sciences (Laboratory for Photogrammetry as well as the Humboldt University in Berlin (Institute for Computer Science: DOTProduct DPI-7, Artec Spider, Mantis Vision F5 SR, Kinect v1 + v2, Structure Sensor and Google’s Project Tango. In the framework of these comparative investigations geometrically stable reference bodies were used. The appropriate reference data were acquired by measurement with two structured light projection systems (AICON smartSCAN and GOM ATOS I 2M. The comprehensive test results of the different test scenarios are presented and critically discussed in this contribution.

  9. A handheld optical device for skin profile measurement

    Science.gov (United States)

    Sun, Jiuai; Liu, Xiaojin

    2018-04-01

    This paper describes a portable optical scanning device designed for skin surface measurement on both colour and 3D geometry through a relative easy and cost effective multiple light source photometric stereo method. The validation of colour recovered had been verified through its application on skin lesion segmentation in our early work. This paper focuses on the reconstructed topographic data which are subject to further evaluation and advancement. The evaluation work takes the skin in vitro as an application scenario and compares the experimental result to that obtained by using a commercial product. The experiments show that this handheld device can measure the skin profile significantly closer to that of the ground truth and have the additional function of skin colour recovery.

  10. Using handheld devices for real-time wireless teleconsultation.

    Science.gov (United States)

    Banitsas, K A; Georgiadis, P; Tachakra, S; Cavouras, D

    2004-01-01

    Recent advances in the hardware of handheld devices, opened up the way for newer applications in the healthcare sector, and more specifically, in the teleconsultation field. Out of these devices, this paper focuses on the services that personal digital assistants and smartphones can provide to improve the speed, quality and ease of delivering a medical opinion from a distance and laying the ground for an all-wireless hospital. In that manner, PDAs were used to wirelessly support the viewing of digital imaging and communication in medicine (DICOM) images and to allow for mobile videoconferencing while within the hospital. Smartphones were also used to carry still images, multiframes and live video outside the hospital. Both of these applications aimed at increasing the mobility of the consultant while improving the healthcare service.

  11. Object localization in handheld thermal images for fireground understanding

    Science.gov (United States)

    Vandecasteele, Florian; Merci, Bart; Jalalvand, Azarakhsh; Verstockt, Steven

    2017-05-01

    Despite the broad application of the handheld thermal imaging cameras in firefighting, its usage is mostly limited to subjective interpretation by the person carrying the device. As remedies to overcome this limitation, object localization and classification mechanisms could assist the fireground understanding and help with the automated localization, characterization and spatio-temporal (spreading) analysis of the fire. An automated understanding of thermal images can enrich the conventional knowledge-based firefighting techniques by providing the information from the data and sensing-driven approaches. In this work, transfer learning is applied on multi-labeling convolutional neural network architectures for object localization and recognition in monocular visual, infrared and multispectral dynamic images. Furthermore, the possibility of analyzing fire scene images is studied and their current limitations are discussed. Finally, the understanding of the room configuration (i.e., objects location) for indoor localization in reduced visibility environments and the linking with Building Information Models (BIM) are investigated.

  12. Naval Prototype Optical Interferometer (NPOI)

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Used for astrometry and astronomical imaging, the Naval Prototype Optical Interferometer (NPOI) is a distributed aperture optical telescope. It is operated...

  13. Mobile prototyping with Axure 7

    CERN Document Server

    Hacker, Will

    2013-01-01

    This book is a step-by-step tutorial which includes hands-on examples and downloadable Axure files to get you started with mobile prototyping immediately. You will learn how to develop an application from scratch, and will be guided through each and every step.If you are a mobile-centric developer/designer, or someone who would like to take their Axure prototyping skills to the next level and start designing and testing mobile prototypes, this book is ideal for you. You should be familiar with prototyping and Axure specifically, before you read this book.

  14. Font size and viewing distance of handheld smart phones.

    Science.gov (United States)

    Bababekova, Yuliya; Rosenfield, Mark; Hue, Jennifer E; Huang, Rae R

    2011-07-01

    The use of handheld smart phones for written communication is becoming ubiquitous in modern society. The relatively small screens found in these devices may necessitate close working distances and small text sizes, which can increase the demands placed on accommodation and vergence. Font size and viewing distance were measured while subjects used handheld electronic devices in two separate trials. In the first study (n=129), subjects were asked to show a typical text message on their own personal phone and to hold the device "as if they were about to read a text message." A second trial was conducted in a similar manner except subjects (n=100) were asked to view a specific web page from the internet. For text messages and internet viewing, the mean font size was 1.1 M (range, 0.7 to 2.1 M) and 0.8 M (range, 0.3 to 1.4 M), respectively. The mean working distance for text messages and internet viewing was 36.2 cm (range, 17.5 to 58.0 cm) and 32.2 cm (range, 19 to 60 cm), respectively. The mean font size for both conditions was comparable with newspaper print, although some subjects viewed text that was considerably smaller. However, the mean working distances were closer than the typical near working distance of 40 cm for adults when viewing hardcopy text. These close distances place increased demands on both accommodation and vergence, which could exacerbate symptoms. Practitioners need to consider the closer distances adopted while viewing material on smart phones when examining patients and prescribing refractive corrections for use at near, as well as when treating patients presenting with asthenopia associated with nearwork. Copyright © 2011 American Academy of Optometry

  15. Prototype Scale Development of an Environmentally Benign Yellow Smoke Hand-Held Signal Formulation Based on Solvent Yellow 33

    Science.gov (United States)

    2013-04-15

    safely implemented in several Navy signaling devices.21,22 ■ EXPERIMENTAL SECTION Materials. Potassium chlorate (MIL-P-150D, grade B, Class 7), sugar...the potassium chlorate overnight at 60 °C, formulations were prepared in 300 g batches by blending all ingredients according to their respective...damage. ■ ASSOCIATED CONTENT *S Supporting Information Particle size analyses for potassium chlorate (Table S1 and Figure S1), sugar (Table S2 and

  16. Texting while driving: is speech-based text entry less risky than handheld text entry?

    Science.gov (United States)

    He, J; Chaparro, A; Nguyen, B; Burge, R J; Crandall, J; Chaparro, B; Ni, R; Cao, S

    2014-11-01

    Research indicates that using a cell phone to talk or text while maneuvering a vehicle impairs driving performance. However, few published studies directly compare the distracting effects of texting using a hands-free (i.e., speech-based interface) versus handheld cell phone, which is an important issue for legislation, automotive interface design and driving safety training. This study compared the effect of speech-based versus handheld text entries on simulated driving performance by asking participants to perform a car following task while controlling the duration of a secondary text-entry task. Results showed that both speech-based and handheld text entries impaired driving performance relative to the drive-only condition by causing more variation in speed and lane position. Handheld text entry also increased the brake response time and increased variation in headway distance. Text entry using a speech-based cell phone was less detrimental to driving performance than handheld text entry. Nevertheless, the speech-based text entry task still significantly impaired driving compared to the drive-only condition. These results suggest that speech-based text entry disrupts driving, but reduces the level of performance interference compared to text entry with a handheld device. In addition, the difference in the distraction effect caused by speech-based and handheld text entry is not simply due to the difference in task duration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Window prototypes during the project

    DEFF Research Database (Denmark)

    Schultz, Jørgen Munthe

    1996-01-01

    The conditions for the PASSYS test and the results of the measurements on one of the aerogel window prototypes are described.......The conditions for the PASSYS test and the results of the measurements on one of the aerogel window prototypes are described....

  18. Rapid prototyping: een veelbelovende methode

    NARCIS (Netherlands)

    Haverman, T.M.; Karagozoglu, K.H.; Prins, H.; Schulten, E.A.J.M.; Forouzanfar, T.

    2013-01-01

    Rapid prototyping is a method which makes it possible to produce a three-dimensional model based on two-dimensional imaging. Various rapid prototyping methods are available for modelling, such as stereolithography, selective laser sintering, direct laser metal sintering, two-photon polymerization,

  19. Role model and prototype matching

    DEFF Research Database (Denmark)

    Lykkegaard, Eva; Ulriksen, Lars

    2016-01-01

    ’ meetings with the role models affected their thoughts concerning STEM students and attending university. The regular self-to-prototype matching process was shown in real-life role-models meetings to be extended to a more complex three-way matching process between students’ self-perceptions, prototype...

  20. Virtual Prototyping at CERN

    Science.gov (United States)

    Gennaro, Silvano De

    The VENUS (Virtual Environment Navigation in the Underground Sites) project is probably the largest Virtual Reality application to Engineering design in the world. VENUS is just over one year old and offers a fully immersive and stereoscopic "flythru" of the LHC pits for the proposed experiments, including the experimental area equipment and the surface models that are being prepared for a territorial impact study. VENUS' Virtual Prototypes are an ideal replacement for the wooden models traditionally build for the past CERN machines, as they are generated directly from the EUCLID CAD files, therefore they are totally reliable, they can be updated in a matter of minutes, and they allow designers to explore them from inside, in a one-to-one scale. Navigation can be performed on the computer screen, on a stereoscopic large projection screen, or in immersive conditions, with an helmet and 3D mouse. By using specialised collision detection software, the computer can find optimal paths to lower each detector part into the pits and position it to destination, letting us visualize the whole assembly probess. During construction, these paths can be fed to a robot controller, which can operate the bridge cranes and build LHC almost without human intervention. VENUS is currently developing a multiplatform VR browser that will let the whole HEP community access LHC's Virtual Protoypes over the web. Many interesting things took place during the conference on Virtual Reality. For more information please refer to the Virtual Reality section.

  1. UA1 prototype detector

    CERN Multimedia

    1980-01-01

    Prototype of UA1 central detector inside a plexi tube. The UA1 experiment ran at CERN's Super Proton Synchrotron and made the Nobel Prize winning discovery of W and Z particles in 1983. The UA1 central detector was crucial to understanding the complex topology of proton-antiproton events. It played a most important role in identifying a handful of Ws and Zs among billions of collisions. The detector was essentially a wire chamber - a 6-chamber cylindrical assembly 5.8 m long and 2.3 m in diameter, the largest imaging drift chamber of its day. It recorded the tracks of charged particles curving in a 0.7 Tesla magnetic field, measuring their momentum, the sign of their electric charge and their rate of energy loss (dE/dx). Atoms in the argon-ethane gas mixture filling the chambers were ionised by the passage of charged particles. The electrons which were released drifted along an electric field shaped by field wires and were collected on sense wires. The geometrical arrangement of the 17000 field wires and 6...

  2. Geocam Space: Enhancing Handheld Digital Camera Imagery from the International Space Station for Research and Applications

    Science.gov (United States)

    Stefanov, William L.; Lee, Yeon Jin; Dille, Michael

    2016-01-01

    advance in geolocation from the manual feature-matching approach for both nadir and off-nadir viewing imagery. With the initial geolocation estimate, full georeferencing of an image is completed using the rapid tie-pointing interface in GeoRef, and the resulting data is added to the Gateway to Astronaut Photography of Earth online database in both Geotiff and Keyhole Markup Language (kml) formats. The integration of the GeoRef software component of Geocam Space into the CEO image cataloging workflow is complete, and disaster response imagery acquired by the ISS crew is now fully georeferenced as a standard data product. The on-orbit hardware component (GeoSens) is in final prototyping phase, and is on-schedule for launch to the ISS in late 2016. Installation and routine use of the Geocam Space system for handheld digital camera photography from the ISS is expected to significantly improve the usefulness of this unique dataset for a variety of public- and private-sector applications.

  3. Gamma camera

    International Nuclear Information System (INIS)

    Berninger, W.H.

    1975-01-01

    The light pulse output of a scintillator, on which incident collimated gamma rays impinge, is detected by an array of photoelectric tubes each having a convexly curved photocathode disposed in close proximity to the scintillator. Electronic circuitry connected to outputs of the phototubes develops the scintillation event position coordinate electrical signals with good linearity and with substantial independence of the spacing between the scintillator and photocathodes so that the phototubes can be positioned as close to the scintillator as is possible to obtain less distortion in the field of view and improved spatial resolution as compared to conventional planar photocathode gamma cameras

  4. Handheld Longwave Infrared Camera Based on Highly-Sensitive Quantum Well Infrared Photodetectors, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop a compact handheld longwave infrared camera based on quantum well infrared photodetector (QWIP) focal plane array (FPA) technology. Based on...

  5. Strength Measurements in Acute Hamstring Injuries: Intertester Reliability and Prognostic Value of Handheld Dynamometry

    NARCIS (Netherlands)

    Reurink, Gustaaf; Goudswaard, Gert Jan; Moen, Maarten H.; Tol, Johannes L.; Verhaar, Jan A. N.; Weir, Adam

    2016-01-01

    Study Design Cohort study, repeated measures. Background Although hamstring strength measurements are used for assessing prognosis and monitoring recovery after hamstring injury, their actual clinical relevance has not been established. Handheld dynamometry (HHD) is a commonly used method of

  6. Discrimination of Pigments of Microalgae, Bacteria and Yeasts Using Lightweight Handheld Raman Spectrometers: Prospects for Astrobiology

    Science.gov (United States)

    Jehlicka, J.; Osterrothova, K.; Nedbalova, L.; Gunde-Cimerman, N.; Oren, A.

    2014-06-01

    Handheld Raman instrumentation with 532 nm lasers can be used to distinguish carotenoids of autotrophic microalgae, purple sulfur bacteria, halophilic Archaea and pigmented yeasts. Pigments are proposed as biomarkers for astrobiology of Mars.

  7. Reusable Handheld Electrolytes and Lab Technology for Humans (rHEALTH Sensor), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of rHEALTH sensor is a universal handheld sensor that can provide rapid, low-cost complete blood count (CBC) with differential, electrolyte analysis, and...

  8. Reusable Handheld Electrolytes and Lab Technology for Humans (rHEALTH Sensor), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of the rHEALTH sensor is to provide rapid, low-cost, handheld complete blood count (CBC), cell differential counts, electrolyte measurements, and other lab...

  9. Handheld low-temperature plasma probe for portable "point-and-shoot" ambient ionization mass spectrometry.

    Science.gov (United States)

    Wiley, Joshua S; Shelley, Jacob T; Cooks, R Graham

    2013-07-16

    We describe a handheld, wireless low-temperature plasma (LTP) ambient ionization source and its performance on a benchtop and a miniature mass spectrometer. The source, which is inexpensive to build and operate, is battery-powered and utilizes miniature helium cylinders or air as the discharge gas. Comparison of a conventional, large-scale LTP source against the handheld LTP source, which uses less helium and power than the large-scale version, revealed that the handheld source had similar or slightly better analytical performance. Another advantage of the handheld LTP source is the ability to quickly interrogate a gaseous, liquid, or solid sample without requiring any setup time. A small, 7.4-V Li-polymer battery is able to sustain plasma for 2 h continuously, while the miniature helium cylinder supplies gas flow for approximately 8 continuous hours. Long-distance ion transfer was achieved for distances up to 1 m.

  10. 78 FR 27441 - NIJ Evaluation of Hand-Held Cell Phone Detector Devices

    Science.gov (United States)

    2013-05-10

    ...The National Institute of Justice (NIJ) is soliciting interest in supplying hand-held cell phone detector devices for participation in an evaluation by the NIJ Corrections Technology Center of Excellence (CXCoE).

  11. Handheld Nonlinear Detection of Delamination and Intrusion Faults in Composites, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In Phase I of the SBIR program, LEEOAT Company will develop a hand-held high-resolution ultrasonic nonlinear imager for non-destructive inspection (NDI) of...

  12. 75 FR 43206 - In the Matter of Certain Wireless Communications System Server Software, Wireless Handheld...

    Science.gov (United States)

    2010-07-23

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-706] In the Matter of Certain Wireless Communications System Server Software, Wireless Handheld Devices and Battery Packs: Notice of Commission... United States after importation of certain wireless communications system server software, wireless...

  13. Who’s That Girl? Handheld Augmented Reality for Printed Photo Books

    OpenAIRE

    Henze , Niels; Boll , Susanne

    2011-01-01

    Part 1: Long and Short Papers; International audience; Augmented reality on mobile phones has recently made major progress. Lightweight, markerless object recognition and tracking makes handheld Augmented Reality feasible for new application domains. As this field is technology driven the interface design has mostly been neglected. In this paper we investigate visualization techniques for augmenting printed documents using handheld Augmented Reality. We selected the augmentation of printed ph...

  14. Fusing Open Source Intelligence and Handheld Situational Awareness - Benghazi Case Study

    Science.gov (United States)

    2014-10-01

    1 DM-0001694 Fusing Open Source Intelligence and Handheld Situational Awareness Benghazi Case Study Jeff Boleng, PhD Marc Novakouski Gene...command and control element at the CIA compound that would have been monitoring OSINT and other sources of intelligence before the attack and... Source Intelligence and Handheld Situational Awareness - Benghazi Case Study 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6

  15. Prospective evaluation of an internet-linked handheld computer critical care knowledge access system.

    Science.gov (United States)

    Lapinsky, Stephen E; Wax, Randy; Showalter, Randy; Martinez-Motta, J Carlos; Hallett, David; Mehta, Sangeeta; Burry, Lisa; Stewart, Thomas E

    2004-12-01

    Critical care physicians may benefit from immediate access to medical reference material. We evaluated the feasibility and potential benefits of a handheld computer based knowledge access system linking a central academic intensive care unit (ICU) to multiple community-based ICUs. Four community hospital ICUs with 17 physicians participated in this prospective interventional study. Following training in the use of an internet-linked, updateable handheld computer knowledge access system, the physicians used the handheld devices in their clinical environment for a 12-month intervention period. Feasibility of the system was evaluated by tracking use of the handheld computer and by conducting surveys and focus group discussions. Before and after the intervention period, participants underwent simulated patient care scenarios designed to evaluate the information sources they accessed, as well as the speed and quality of their decision making. Participants generated admission orders during each scenario, which were scored by blinded evaluators. Ten physicians (59%) used the system regularly, predominantly for nonmedical applications (median 32.8/month, interquartile range [IQR] 28.3-126.8), with medical software accessed less often (median 9/month, IQR 3.7-13.7). Eight out of 13 physicians (62%) who completed the final scenarios chose to use the handheld computer for information access. The median time to access information on the handheld handheld computer was 19 s (IQR 15-40 s). This group exhibited a significant improvement in admission order score as compared with those who used other resources (P = 0.018). Benefits and barriers to use of this technology were identified. An updateable handheld computer system is feasible as a means of point-of-care access to medical reference material and may improve clinical decision making. However, during the study, acceptance of the system was variable. Improved training and new technology may overcome some of the barriers we

  16. Prototype explosives detection system based on nuclear resonance absorption in nitrogen

    International Nuclear Information System (INIS)

    Morgado, R.E.; Arnone, G.J.; Cappiello, C.C.

    1996-01-01

    A laboratory prototype system has been developed for the experimental evaluation of an explosives detection technique based on nuclear resonance absorption of gamma rays in nitrogen. Major subsystems include a radiofrequency quadrupole proton accelerator and associated beam transport system, a high-power gamma-ray production target, an airline-luggage tomographic inspection system, and an image- processing/detection-alarm subsystem. The detection system performance, based on a limited experimental test, is reported

  17. Gamma camera

    International Nuclear Information System (INIS)

    Tschunt, E.; Platz, W.; Baer, Ul; Heinz, L.

    1978-01-01

    A gamma camera has a plurality of exchangeable collimators, one of which is replaceably mounted in the ray inlet opening of the camera, while the others are placed on separate supports. Supports are swingably mounted upon a column one above the other

  18. Gamma camera

    International Nuclear Information System (INIS)

    Schlosser, P.A.; Steidley, J.W.

    1980-01-01

    The design of a collimation system for a gamma camera for use in nuclear medicine is described. When used with a 2-dimensional position sensitive radiation detector, the novel system can produce superior images than conventional cameras. The optimal thickness and positions of the collimators are derived mathematically. (U.K.)

  19. Improving car passengers' comfort and experience by supporting the use of handheld devices.

    Science.gov (United States)

    van Veen, S A T; Hiemstra-van Mastrigt, S; Kamp, I; Vink, P

    2014-01-01

    There is a demand for interiors to support other activities in a car than controlling the vehicle. Currently, this is the case for the car passengers and--in the future--autonomous driving cars will also facilitate drivers to perform other activities. One of these activities is working with handheld devices. Previous research shows that people experience problems when using handheld devices in a moving vehicle and the use of handheld devices generally causes unwanted neck flexion [Young et al. 2012; Sin and Zu 2011; Gold et al.2011]. In this study, armrests are designed to support the arms when using handheld devices in a driving car in order to decrease neck flexion. Neck flexion was measured by attaching markers on the C7 and tragus. Discomfort was indicated on a body map on a scale 1-10. User experience was evaluated in a semi-structured interview. Neck flexion is significantly decreased by the support of the armrests and approaches a neutral position. Furthermore, overall comfort and comfort in the neck region specifically are significantly increased. Subjects appreciate the body posture facilitated by the armrests and 9 out of 10 prefer using handheld devices with the armrests compared to using handheld devices without the armrests. More efforts are needed to develop the mock-up into an established product, but the angles and dimensions presented in this study could serve as guidelines.

  20. Using medical knowledge sources on handheld computers--a qualitative study among junior doctors.

    Science.gov (United States)

    Axelson, Christian; Wårdh, Inger; Strender, Lars-Erik; Nilsson, Gunnar

    2007-09-01

    The emergence of mobile computing could have an impact on how junior doctors learn. To exploit this opportunity it is essential to understand their information seeking process. To explore junior doctors' experiences of using medical knowledge sources on handheld computers. Interviews with five Swedish junior doctors. A qualitative manifest content analysis of a focus group interview followed by a qualitative latent content analysis of two individual interviews. A focus group interview showed that users were satisfied with access to handheld medical knowledge sources, but there was concern about contents, reliability and device dependency. Four categories emerged from individual interviews: (1) A feeling of uncertainty about using handheld technology in medical care; (2) A sense of security that handhelds can provide; (3) A need for contents to be personalized; (4) A degree of adaptability to make the handheld a versatile information tool. A theme was established to link the four categories together, as expressed in the Conclusion section. Junior doctors' experiences of using medical knowledge sources on handheld computers shed light on the need to decrease uncertainty about clinical decisions during medical internship, and to find ways to influence the level of self-confidence in the junior doctor's process of decision-making.

  1. Development and testing of a scale to assess physician attitudes about handheld computers with decision support.

    Science.gov (United States)

    Ray, Midge N; Houston, Thomas K; Yu, Feliciano B; Menachemi, Nir; Maisiak, Richard S; Allison, Jeroan J; Berner, Eta S

    2006-01-01

    The authors developed and evaluated a rating scale, the Attitudes toward Handheld Decision Support Software Scale (H-DSS), to assess physician attitudes about handheld decision support systems. The authors conducted a prospective assessment of psychometric characteristics of the H-DSS including reliability, validity, and responsiveness. Participants were 82 Internal Medicine residents. A higher score on each of the 14 five-point Likert scale items reflected a more positive attitude about handheld DSS. The H-DSS score is the mean across the fourteen items. Attitudes toward the use of the handheld DSS were assessed prior to and six months after receiving the handheld device. Cronbach's Alpha was used to assess internal consistency reliability. Pearson correlations were used to estimate and detect significant associations between scale scores and other measures (validity). Paired sample t-tests were used to test for changes in the mean attitude scale score (responsiveness) and for differences between groups. Internal consistency reliability for the scale was alpha = 0.73. In testing validity, moderate correlations were noted between the attitude scale scores and self-reported Personal Digital Assistant (PDA) usage in the hospital (correlation coefficient = 0.55) and clinic (0.48), p DSS scale was reliable, valid, and responsive. The scale can be used to guide future handheld DSS development and implementation.

  2. Prototype moving-ring reactor

    International Nuclear Information System (INIS)

    Smith, A.C. Jr.; Ashworth, C.P.; Abreu, K.E.

    1981-01-01

    The objective of this work was to design a prototype fusion reactor based on fusion plasmas confined as ''Compact Toruses.' Six major criteria guided the prototype design. The prototype must: (1) produce net electricity decisively (P/sub net/ >70% of P/sub gross/), with P/sub net/ approximately 100 MW(e); (2) have small physical size (low project cost) but commercial plant; (3) have all features required of commerical plants; (4) avoid unreasonable extrapolation of technology; (5) minimize nuclear issues substantially, i.e. accident and waste issues of public concern, and (6) be modular (to permit repetitive fabrication of parts) and be maintainable with low occupational radiological exposures

  3. Attentionally splitting the mass distribution of hand-held rods.

    Science.gov (United States)

    Burton, G; Turvey, M T

    1991-08-01

    Two experiments on the length-perception capabilities of effortful or dynamic touch differed only in terms of what the subject intended to perceive, while experimental conditions and apparatus were held constant. In each trial, a visually occluded rod was held as still as possible by the subject at an intermediate position. For two thirds of the trials, a weight was attached to the rod above or below the hand. In Experiment 1, in which the subject's task was to perceive the distance reachable with the portion of the rod forward of the hand, perceived extent was a function of the first moment of the mass distribution associated with the forward portion of the rod, and indifferent to the first moment of the entire rod. In Experiment 2, in which the task was to perceive the distance reachable with the entire rod if it was held at an end, the pattern of results was reversed. These results indicate the capability of selective sensitivity to different aspects of a hand-held object's mass distribution, without the possibility of differential exploration specific to these two tasks. Results are discussed in relation to possible roles of differential information, intention, and self-organization in the explanations of selective perceptual abilities.

  4. Robust sleep quality quantification method for a personal handheld device.

    Science.gov (United States)

    Shin, Hangsik; Choi, Byunghun; Kim, Doyoon; Cho, Jaegeol

    2014-06-01

    The purpose of this study was to develop and validate a novel method for sleep quality quantification using personal handheld devices. The proposed method used 3- or 6-axes signals, including acceleration and angular velocity, obtained from built-in sensors in a smartphone and applied a real-time wavelet denoising technique to minimize the nonstationary noise. Sleep or wake status was decided on each axis, and the totals were finally summed to calculate sleep efficiency (SE), regarded as sleep quality in general. The sleep experiment was carried out for performance evaluation of the proposed method, and 14 subjects participated. An experimental protocol was designed for comparative analysis. The activity during sleep was recorded not only by the proposed method but also by well-known commercial applications simultaneously; moreover, activity was recorded on different mattresses and locations to verify the reliability in practical use. Every calculated SE was compared with the SE of a clinically certified medical device, the Philips (Amsterdam, The Netherlands) Actiwatch. In these experiments, the proposed method proved its reliability in quantifying sleep quality. Compared with the Actiwatch, accuracy and average bias error of SE calculated by the proposed method were 96.50% and -1.91%, respectively. The proposed method was vastly superior to other comparative applications with at least 11.41% in average accuracy and at least 6.10% in average bias; average accuracy and average absolute bias error of comparative applications were 76.33% and 17.52%, respectively.

  5. Dual-modality imaging with a ultrasound-gamma device for oncology

    Science.gov (United States)

    Polito, C.; Pellegrini, R.; Cinti, M. N.; De Vincentis, G.; Lo Meo, S.; Fabbri, A.; Bennati, P.; Cencelli, V. Orsolini; Pani, R.

    2018-06-01

    Recently, dual-modality systems have been developed, aimed to correlate anatomical and functional information, improving disease localization and helping oncological or surgical treatments. Moreover, due to the growing interest in handheld detectors for preclinical trials or small animal imaging, in this work a new dual modality integrated device, based on a Ultrasounds probe and a small Field of View Single Photon Emission gamma camera, is proposed.

  6. Learning Axure RP interactive prototypes

    CERN Document Server

    Krahenbuhl, John Henry

    2015-01-01

    If you are a user experience professional, designer, information architect, or business analyst who wants to gain interactive prototyping skills with Axure, then this book is ideal for you. Some familiarity with Axure is preferred but not essential.

  7. Architectural Prototyping in Industrial Practice

    DEFF Research Database (Denmark)

    Christensen, Henrik Bærbak; Hansen, Klaus Marius

    2008-01-01

    Architectural prototyping is the process of using executable code to investigate stakeholders’ software architecture concerns with respect to a system under development. Previous work has established this as a useful and cost-effective way of exploration and learning of the design space of a system......, in addressing issues regarding quality attributes, in addressing architectural risks, and in addressing the problem of knowledge transfer and conformance. Little work has been reported so far on the actual industrial use of architectural prototyping. In this paper, we report from an ethnographical study...... and focus group involving architects from four companies in which we have focused on architectural prototypes. Our findings conclude that architectural prototypes play an important role in resolving problems experimentally, but less so in exploring alternative solutions. Furthermore, architectural...

  8. Experimentation with PEC channel prototype

    International Nuclear Information System (INIS)

    Caponetti, R.; Iacovelli, M.

    1984-01-01

    Experimentation on prototypes of PEC components is presently being carried out at Casaccia CRE. This report shows the results of the first cycle of experimentation of the central channel, concerning the aspects of sodium removal after experimentation

  9. Tangiplay: prototyping tangible electronic games

    OpenAIRE

    Boileau, Jason

    2010-01-01

    Tangible electronic games currently exist in research laboratories around the world but have yet to transition to the commercial sector. The development process of a tangible electronic game is one of the factors preventing progression, as it requires much time and money. Prototyping tools for tangible hardware and software development are becoming more available but are targeted to programmers and technically trained developers. Paper prototyping board and video games is a proven and rapid m...

  10. Fast-prototyping of VLSI

    International Nuclear Information System (INIS)

    Saucier, G.; Read, E.

    1987-01-01

    Fast-prototyping will be a reality in the very near future if both straightforward design methods and fast manufacturing facilities are available. This book focuses, first, on the motivation for fast-prototyping. Economic aspects and market considerations are analysed by European and Japanese companies. In the second chapter, new design methods are identified, mainly for full custom circuits. Of course, silicon compilers play a key role and the introduction of artificial intelligence techniques sheds a new light on the subject. At present, fast-prototyping on gate arrays or on standard cells is the most conventional technique and the third chapter updates the state-of-the art in this area. The fourth chapter concentrates specifically on the e-beam direct-writing for submicron IC technologies. In the fifth chapter, a strategic point in fast-prototyping, namely the test problem is addressed. The design for testability and the interface to the test equipment are mandatory to fulfill the test requirement for fast-prototyping. Finally, the last chapter deals with the subject of education when many people complain about the lack of use of fast-prototyping in higher education for VLSI

  11. Gamma camera

    International Nuclear Information System (INIS)

    Reiss, K.H.; Kotschak, O.; Conrad, B.

    1976-01-01

    A gamma camera with a simplified setup as compared with the state of engineering is described permitting, apart from good localization, also energy discrimination. Behind the usual vacuum image amplifier a multiwire proportional chamber filled with trifluorine bromium methane is connected in series. Localizing of the signals is achieved by a delay line, energy determination by means of a pulse height discriminator. With the aid of drawings and circuit diagrams, the setup and mode of operation are explained. (ORU) [de

  12. Gamma irradiator

    International Nuclear Information System (INIS)

    Simonet, G.

    1986-09-01

    Fiability of devices set around reactors depends on material resistance under irradiation noticeably joints, insulators, which belongs to composition of technical, safety or physical incasurement devices. The irradiated fuel elements, during their desactivation in a pool, are an interesting gamma irradiation device to simulate damages created in a nuclear environment. The existing facility at Osiris allows to generate an homogeneous rate dose in an important volume. The control of the element distances to irradiation box allows to control this dose rate [fr

  13. Electronic prescribing: criteria for evaluating handheld prescribing systems and an evaluation of a new, handheld, wireless wide area network (WWAN) prescribing system.

    Science.gov (United States)

    Goldblum, O M

    2001-02-01

    The objectives of this study were: 1) to establish criteria for evaluating handheld computerized prescribing systems; and 2) to evaluate out-of-box performance and features of a new, Palm Operating System (OS)-based, handheld, wireless wide area network (WWAN) prescribing system. The system consisted of a Palm Vx handheld organizer, a Novatel Minstrel V wireless modem, OmniSky wireless internet access and ePhysician ePad 1.1, the Palm OS electronic prescribing software program. A dermatologist familiar with healthcare information technology conducted an evaluation of the performance and features of a new, handheld, WWAN electronic prescribing system in an office practice during a three-month period in 2000. System performance, defined as transmission success rate, was determined from data collected during the three-month trial. Evaluation criteria consisted of an analysis of features found in electronic prescribing systems. All prescriptions written for all patients seen during a three-month period (August - November, 2000) were eligible for inclusion. Prescriptions written for patients who intended to fill them at pharmacies without known facsimile receiving capabilities were excluded from the study. The performance of the system was evaluated using data collected during the study. Criteria for evaluating features of electronic prescribing systems were developed and used to analyze the system employed in this study. During this three-month trial, 200 electronic prescriptions were generated for 132 patients included in the study. Of these prescriptions, 92.5 percent were successfully transmitted to pharmacies. Transmission failures resulted from incorrect facsimile numbers and non-functioning facsimile machines. Criteria established for evaluation of electronic prescribing systems included System (Hardware & Software), Costs, System Features, Printing & Transmission, Formulary & Insurance, Customization, Drug Safety and Security. This study is the first effort to

  14. Gamma teletopography

    International Nuclear Information System (INIS)

    Simonet, G.

    1987-06-01

    The mapping of gamma sources radiation emission in a nuclear plant is an important safety point. A remote gamma ray mapping process was developed in SPS/CEA/SACLAY. It uses the ''pinhole camera'' principle, precursor of photography. It mainly consists of a radiation proof box, with a small orifice, containing sensitive emulsions at the opposite. A first conventional photographic type emulsion photographs the area. A second photographic emulsion shows up the gamma radiations. The superim position of the two shots gives immediate informations of the precise location of each source of radiation in the observed area. To make easier the presentation and to improve the accuracy of the results for radiation levels mapping, the obtained films are digitally processed. The processing assigns a colours scale to the various levels of observed radiations. Taking account physical data and standard parameters, it gets possible to estimate the dose rate. The device is portable. Its compactness and fully independent nature make it suitable for use anywhere. It can be adapted to a remote automatic handling system, robot... so as to avoid all operator exposure when the local dose rate is too high [fr

  15. A prototype wearable tritium monitor

    International Nuclear Information System (INIS)

    Surette, R. A.; Dubeau, J.

    2008-01-01

    Sudden unexpected changes in tritium-in-air concentrations in workplace air can result in significant unplanned exposures. Although fixed area monitors are used to monitor areas where there is a potential for elevated tritium in air concentrations, they do not monitor personnel air space and may require some time for acute tritium releases to be detected. There is a need for a small instrument that will quickly alert staff of changing tritium hazards. A moderately sensitive tritium instrument that workers could wear would bring attention to any rise in tritium levels that were above predetermined limits and help in assessing the potential hazard therefore minimizing absorbed dose. Hand-held instruments currently available can be used but require the assistance of a fellow worker or restrict the user to using only one hand to perform some duties. (authors)

  16. Portable Hand-Held Electrochemical Sensor for the Transuranics

    Energy Technology Data Exchange (ETDEWEB)

    Dale D. Russell, William B. Knowlton, Ph.D.; Russel Hertzog, Ph.D

    2005-11-25

    sensitive detector for uranium. Millimeter scale electrodes, operated by a hand-held instrument assembled in this lab and operated in the voltammetric mode, were transported to the DOE-Nevada test site (Las Vegas, NV) where field detection and quantitation of plutonium, uranium, and a mixture of these two elements was also demonstrated. Several probe designs were prepared, built and tested including probes with movable protective windows. A miniature, battery powered potentiostat was designed, built and demonstrated for use in a hand-held field portable instrument. This work was performed largely by undergraduates who gained valuable research experience, and many of them have continued on to graduate schools. In addition, they all gained exposure to and appreciation for national security research, in particular non-proliferation research. Four graduate students participated and one earned the MS degree on this project.

  17. Handheld echocardiography during hospitalization for acute myocardial infarction.

    Science.gov (United States)

    Cullen, Michael W; Geske, Jeffrey B; Anavekar, Nandan S; Askew, J Wells; Lewis, Bradley R; Oh, Jae K

    2017-11-01

    Handheld echocardiography (HHE) is concordant with standard transthoracic echocardiography (TTE) in a variety of settings but has not been thoroughly compared to traditional TTE in patients with acute myocardial infarction (AMI). Completed by experienced operators, HHE provides accurate diagnostic capabilities compared with standard TTE in AMI patients. This study prospectively enrolled patients admitted to the coronary care unit with AMI. Experienced sonographers performed HHE with a V-scan. All patients underwent clinical TTE. Each HHE was interpreted by 2 experts blinded to standard TTE. Agreement was assessed with κ statistics and concordance correlation coefficients. Analysis included 82 patients (mean age, 66 years; 74% male). On standard TTE, mean left ventricular (LV) ejection fraction was 46%. Correlation coefficients between HHE and TTE were 0.75 (95% confidence interval: 0.66 to 0.82) for LV ejection fraction and 0.69 (95% confidence interval: 0.58 to 0.77) for wall motion score index. The κ statistics ranged from 0.47 to 0.56 for LV enlargement, 0.55 to 0.79 for mitral regurgitation, and 0.44 to 0.57 for inferior vena cava dilatation. The κ statistics were highest for the anterior (0.81) and septal (0.71) apex and lowest for the mid inferolateral (0.36) and basal inferoseptal (0.36) walls. In patients with AMI, HHE and standard TTE demonstrate good correlation for LV function and wall motion. Agreement was less robust for structural abnormalities and specific wall segments. In experienced hands, HHE can provide a focused assessment of LV function in patients hospitalized with AMI; however, HHE should not substitute for comprehensive TTE. © 2017 Wiley Periodicals, Inc.

  18. Handheld echocardiography versus auscultation for detection of rheumatic heart disease.

    Science.gov (United States)

    Godown, Justin; Lu, Jimmy C; Beaton, Andrea; Sable, Craig; Mirembe, Grace; Sanya, Richard; Aliku, Twalib; Yu, Sunkyung; Lwabi, Peter; Webb, Catherine L; Ensing, Gregory J

    2015-04-01

    Rheumatic heart disease (RHD) remains a major public health concern in developing countries, and routine screening has the potential to improve outcomes. Standard portable echocardiography (STAND) is far more sensitive than auscultation for the detection of RHD but remains cost-prohibitive in resource-limited settings. Handheld echocardiography (HAND) is a lower-cost alternative. The purpose of this study was to assess the incremental value of HAND over auscultation to identify RHD. RHD screening was completed for schoolchildren in Gulu, Uganda, by using STAND performed by experienced echocardiographers. Any child with mitral or aortic regurgitation or stenosis plus a randomly selected group of children with normal STAND findings underwent HAND and auscultation. STAND and HAND studies were interpreted by 6 experienced cardiologists using the 2012 World Heart Federation criteria. Sensitivity and specificity of HAND and auscultation for the detection of RHD and pathologic mitral or aortic regurgitation were calculated by using STAND as the gold standard. Of 4773 children who underwent screening with STAND, a subgroup of 1317 children underwent HAND and auscultation. Auscultation had uniformly poor sensitivity for the detection of RHD or valve disease. Sensitivity was significantly improved by using HAND compared with auscultation for the detection of definite RHD (97.8% vs 22.2%), borderline or definite RHD (78.4% vs 16.4%), and pathologic aortic insufficiency (81.8% vs 13.6%). Auscultation alone is a poor screening test for RHD. HAND significantly improves detection of RHD and may be a cost-effective screening strategy for RHD in resource-limited settings. Copyright © 2015 by the American Academy of Pediatrics.

  19. A handheld point-of-care genomic diagnostic system.

    Directory of Open Access Journals (Sweden)

    Frank B Myers

    Full Text Available The rapid detection and identification of infectious disease pathogens is a critical need for healthcare in both developed and developing countries. As we gain more insight into the genomic basis of pathogen infectivity and drug resistance, point-of-care nucleic acid testing will likely become an important tool for global health. In this paper, we present an inexpensive, handheld, battery-powered instrument designed to enable pathogen genotyping in the developing world. Our Microfluidic Biomolecular Amplification Reader (µBAR represents the convergence of molecular biology, microfluidics, optics, and electronics technology. The µBAR is capable of carrying out isothermal nucleic acid amplification assays with real-time fluorescence readout at a fraction of the cost of conventional benchtop thermocyclers. Additionally, the µBAR features cell phone data connectivity and GPS sample geotagging which can enable epidemiological surveying and remote healthcare delivery. The µBAR controls assay temperature through an integrated resistive heater and monitors real-time fluorescence signals from 60 individual reaction chambers using LEDs and phototransistors. Assays are carried out on PDMS disposable microfluidic cartridges which require no external power for sample loading. We characterize the fluorescence detection limits, heater uniformity, and battery life of the instrument. As a proof-of-principle, we demonstrate the detection of the HIV-1 integrase gene with the µBAR using the Loop-Mediated Isothermal Amplification (LAMP assay. Although we focus on the detection of purified DNA here, LAMP has previously been demonstrated with a range of clinical samples, and our eventual goal is to develop a microfluidic device which includes on-chip sample preparation from raw samples. The µBAR is based entirely around open source hardware and software, and in the accompanying online supplement we present a full set of schematics, bill of materials, PCB layouts

  20. Ultrasonography with a hand-held device for the diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Kameda, Toru; Takahashi, Isao

    2009-01-01

    The purpose of this study was to evaluate the accuracy of ultrasonography (US) with a hand-held device for the diagnosis of acute appendicitis in the emergency room. US with a hand-held device was performed by the first author in 33 patients suspected of having appendicitis in the emergency room. From these 33 patients, 24 who subsequently underwent computed tomography (CT) or surgery were included in this study. The accuracy of US with the hand-held device for the diagnosis of acute appendicitis was evaluated based on the findings of CT or surgery. CT and surgery were performed in 22 and 12 patients, respectively. Final diagnoses were acute appendicitis (n=18), terminal ileitis (n=2), pelvic inflammatory disease (n=2), diverticulitis (n=1), and ureterolithiasis (n=1). The US yielded a sensitivity of 78% and a positive predictive value of 100%. The shortest distance between the abdominal wall and the appendix measured on CT was less than 40 mm in 11 patients. In ten (91%) of the 11 patients US with the hand-held device showed the swollen appendix. US with a hand-held device is potentially useful in the positive identification of acute appendicitis, but further investigation is needed to prove its utility in the routine diagnosis of acute appendicitis. (author)

  1. Prototypes in engineering design: Definitions and strategies

    DEFF Research Database (Denmark)

    Jensen, Lasse Skovgaard; Özkil, Ali Gürcan; Mortensen, Niels Henrik

    2016-01-01

    By reviewing literature, we investigate types, purposes and definitions of prototypes. There is no overarching definition of a prototype, but we identify five categories of prototypes in litterature. We further synthesize and reference previous work to create an overview of aspects in prototyping...

  2. Prototyping in theory and in practice

    DEFF Research Database (Denmark)

    Yu, Fei; Brem, Alexander; Pasinell, Michele

    2018-01-01

    and functions of a prototype and needed to meet specific goals in order to push the process forward. Designers, on the other hand, used prototypes to investigate the design space for new possibilities, and were more open to a variety of prototyping materials and tools, especially for low-fidelity prototypes...

  3. Rapid Prototyping of Formally Modelled Distributed Systems

    OpenAIRE

    Buchs, Didier; Buffo, Mathieu; Titsworth, Frances M.

    1999-01-01

    This paper presents various kinds of prototypes, used in the prototyping of formally modelled distributed systems. It presents the notions of prototyping techniques and prototype evolution, and shows how to relate them to the software life-cycle. It is illustrated through the use of the formal modelling language for distributed systems CO-OPN/2.

  4. Towards an Operational Framework for Architectural Prototyping

    DEFF Research Database (Denmark)

    Christensen, Henrik Bærbak

    2005-01-01

    We use a case study in architectural prototyping as input for presenting a first, tentative, framework describing key concepts and their relationships in architectural prototyping processes.......We use a case study in architectural prototyping as input for presenting a first, tentative, framework describing key concepts and their relationships in architectural prototyping processes....

  5. Engineering prototypes for theta-pinch devices

    International Nuclear Information System (INIS)

    Hansborough, L.D.; Hammer, C.F.; Hanks, K.W.; McDonald, T.E.; Nunnally, W.C.

    1975-01-01

    Past, present, and future engineering prototypes for theta-pinch plasma-physics devices at Los Alamos Scientific Laboratory are discussed. Engineering prototypes are designed to test and evaluate all components under system conditions expected on actual plasma-physics experimental devices. The importance of engineering prototype development increases as the size and complexity of the plasma-physics device increases. Past experiences with the Scyllac prototype and the Staged Theta-Pinch prototype are discussed and evaluated. The design of the proposed Staged Scyllac prototype and the Large Staged Scyllac implosion prototype assembly are discussed

  6. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase III of the Prototypical Rod Consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod Consolidation System as described in the NUS Phase II Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase III effort the system was tested on a component, subsystem, and system level. Volume IV provides the Operating and Maintenance Manual for the Prototypical Rod Consolidation System that was installed at the Cold Test Facility. This document, Book 1 of Volume IV, discusses: Process overview functional descriptions; Control system descriptions; Support system descriptions; Maintenance system descriptions; and Process equipment descriptions

  7. Flight Telerobotic Servicer prototype simulator

    Science.gov (United States)

    Schein, Rob; Krauze, Linda; Hartley, Craig; Dickenson, Alan; Lavecchia, Tom; Working, Bob

    A prototype simulator for the Flight Telerobotic Servicer (FTS) system is described for use in the design development of the FTS, emphasizing the hand controller and user interface. The simulator utilizes a graphics workstation based on rapid prototyping tools for systems analyses of the use of the user interface and the hand controller. Kinematic modeling, manipulator-control algorithms, and communications programs are contained in the software for the simulator. The hardwired FTS panels and operator interface for use on the STS Orbiter are represented graphically, and the simulated controls function as the final FTS system configuration does. The robotic arm moves based on the user hand-controller interface, and the joint angles and other data are given on the prototype of the user interface. This graphics simulation tool provides the means for familiarizing crewmembers with the FTS system operation, displays, and controls.

  8. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase III of the Prototypical Rod Consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod Consolidation System as described in the NUS Phase II Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase III effort the system was tested on a component, subsystem, and system level. Volume IV provides the Operating and Maintenance Manual for the Prototypical Rod Consolidation System that was installed at the Cold Test Facility. This document, Book 4 of Volume IV, discusses: Off-normal operating and recovery procedures; Emergency response procedures; Troubleshooting procedures; and Preventive maintenance procedures

  9. Gamma teletopography

    International Nuclear Information System (INIS)

    Simonet, G.

    1986-09-01

    To set the gamma activity cartography is an important element of safety in numerous cases: intervention in hot cell, search of a radioactive source, examination of radioactive waste circuit followed by a reprocessing definition of decontamination and decommissioning processes and for all other accidents. The device presented here is like a ''black box'' with an aperture and an emulsion photosensitive to the opposite; a classical film takes photography of the place; a X-ray type emulsion gives a spot more or less contrasted and extensive corresponding to each source. Images can be processed with a microprocessor [fr

  10. The ASTRI SST-2M prototype for the Cherenkov Telescope Array: prototype technologies goals and strategies for the future SST

    Science.gov (United States)

    Marchiori, Gianpietro; Busatta, Andrea; Giacomel, Stefano; Folla, Ivan; Valsecchi, Marco; Canestrari, Rodolfo; Bonnoli, Giacomo; Cascone, Enrico; Conconi, Paolo; Fiorini, Mauro; Giro, Enrico; La Palombara, Nicola; Pareschi, Giovanni; Perri, Luca; Rodeghiero, Gabriele; Sironi, Giorgia; Stringhetti, Luca; Toso, Giorgio; Tosti, Gino; Pellicciari, Carlo

    2014-07-01

    The Cherenkov Telescope Array (CTA) observatory will represent the next generation of Imaging Atmospheric Cherenkov Telescope. Using a combination of large-, medium-, and small-scale telescopes (LST, MST, SST, respectively), it will explore the Very High Energy domain from a few tens of GeVup to about few hundreds of TeV with unprecedented sensitivity, angular resolution and imaging quality. In this framework, the Italian ASTRI program, led by the Italian National Institute of Astrophysics (INAF) developed a 4-meter class telescope, which will adopt an aplanatic, wide-field, double-reflection optical layout in a Schwarzschild- Couder configuration. Within this program INAF assigned to the consortium between Galbiati Group and EIE Group the construction, assembly and tests activities of the prototype named ASTRI SST-2M. On the basis of the lesson learnt from the prototype, other telescopes will be produced, starting from a re-design phase, in order to optimize performances and the overall costs and production schedule for the CTA-SST telescope. This paper will firstly give an overview of the concept for the SST prototype mount structure. In this contest, the technologies adopted for the design, manufacturing and tests of the entire system will be presented. Moreover, a specific focus on the challenges of the prototype and the strategies associated with it will be provided, in order to outline the near future performance goals for this type of Cherenkov telescopes employed for Gamma ray science.

  11. Nuclear instrumentation systems in prototype fast breeder reactor

    International Nuclear Information System (INIS)

    Vijayakumaran, P.M.; Nagaraj, C.P.; Paramasivan-Pillai, C.; Ramakrishnan, R.; Sivaramakrishna, M.

    2004-01-01

    The nuclear instrumentation systems of the Prototype Fast Breeder Reactor (PFBR) primarily comprise of global Neutron Flux Monitoring, Failed Fuel Detection and Location, Radiation Monitoring and Post-Accident Monitoring. High temperature fission chambers are provided at in-vessel locations for monitoring neutron flux. Failed fuel detection and location is by monitoring the cover gas for fission gases and primary sodium for delayed neutrons. Signals of the core monitoring detectors are used to initiate SCRAM (safety action) to protect the reactor from various postulated initiating events. Radiation levels in all potentially radioactive areas are monitored to act as an early warning system to keep the release of radioactivity to the environment and exposure to personnel well below the permissible limits. Fission Chambers and Gamma Ionisation Chambers are located in the reactor vault concrete for monitoring the neutron flux and gamma radiation levels during and after an accident. (authors)

  12. Axure RP 6 Prototyping Essentials

    CERN Document Server

    Schwartz, Ezra

    2012-01-01

    Axure RP 6 Prototyping Essentials is a detailed, practical primer on the leading rapid prototyping tool. Short on jargon and high on concepts, real-life scenarios and step-by-step guidance through hands-on examples, this book will show you how to integrate Axure into your UX workflow. This book is written for UX practitioners, business analysts, product managers, and anyone else who is involved in UX projects. The book assumes that you have no or very little familiarity with Axure. It will help you if you are evaluating the tool for an upcoming project or are required to quickly get up to spee

  13. Gamma knife

    International Nuclear Information System (INIS)

    Kawamoto, Shunsuke; Takakura, Kintomo

    1991-01-01

    As to the gamma knife which is the radiation surgery device developed in Sweden a quarter century ago, its principle, structure, treatment techniques, already established clinical effect and the problems being left for hereafter are described. This treatment means supplements the operation under microscopes, and at present it takes the important position in neurosurgery, but hereafter, by the interdisciplinary cooperation of neurosurgery and clinical radiobiology, the more development can be expected. The method of irradiating the radiation of high dose selectively to a target region and breaking its tissue is called radiosurgery, and the device developed for this purpose is the gamma knife. First, it was applied to functional diseases, but good results were obtained by its application to auditory nerve and brain blood vessels, and it establishes the position as the safe treatment method of the morbid state in the deep part of brains, which is difficult to reach by operation. Accompanying the recent progress of the operation of skull base part, attention is paid to its application to various tumors in skull base. On the other hand, the radiosurgery combining a cyclotron or a linear accelerator with stereotaxic brain surgery is actively tried mainly to the deformation of brain blood vessels. (K.I.)

  14. Towards Vision-Based Control of a Handheld Micromanipulator for Retinal Cannulation in an Eyeball Phantom

    Science.gov (United States)

    Becker, Brian C.; Yang, Sungwook; MacLachlan, Robert A.; Riviere, Cameron N.

    2012-01-01

    Injecting clot-busting drugs such as t-PA into tiny vessels thinner than a human hair in the eye is a challenging procedure, especially since the vessels lie directly on top of the delicate and easily damaged retina. Various robotic aids have been proposed with the goal of increasing safety by removing tremor and increasing precision with motion scaling. We have developed a fully handheld micromanipulator, Micron, that has demonstrated reduced tremor when cannulating porcine retinal veins in an “open sky” scenario. In this paper, we present work towards handheld robotic cannulation with the goal of vision-based virtual fixtures guiding the tip of the cannula to the vessel. Using a realistic eyeball phantom, we address sclerotomy constraints, eye movement, and non-planar retina. Preliminary results indicate a handheld micromanipulator aided by visual control is a promising solution to retinal vessel occlusion. PMID:24649479

  15. Position statement on use of hand-held portable dental X-ray equipment

    International Nuclear Information System (INIS)

    2014-06-01

    The position statement focuses on justification in the medical field, in particular on the use of hand-held portable dental x-ray equipment. It supplements another HERCA position paper, providing a general overview of the use of all hand-held portable X-ray equipment. Key Messages: - HERCA finds that the use of hand-held portable X-ray devices should be discouraged except in special circumstances. - As a general rule, these devices should only be used in scenarios where an intraoral radiograph is deemed necessary for a patient and the use of a fixed or semi-mobile x-ray unit is impractical, e.g.: - nursing homes, residential care facilities or homes for persons with disabilities; - forensic odontology, - military operations abroad without dental facilities

  16. A Compton Imaging Prototype for Range Verification in Particle Therapy

    International Nuclear Information System (INIS)

    Golnik, C.; Hueso Gonzalez, F.; Kormoll, T.; Pausch, G.; Rohling, H.; Fiedler, F.; Heidel, K.; Schoene, S.; Sobiella, M.; Wagner, A.; Enghardt, W.

    2013-06-01

    During the 2012 AAPM Annual Meeting 33 percent of the delegates considered the range uncertainty in proton therapy as the main obstacle of becoming a mainstream treatment modality. Utilizing prompt gamma emission, a side product of particle tissue interaction, opens the possibility of in-beam dose verification, due to the direct correlation between prompt gamma emission and particle dose deposition. Compton imaging has proven to be a technique to measure three dimensional gamma emission profiles and opens the possibility of adaptive dose monitoring and treatment correction. We successfully built a Compton Imaging prototype, characterized the detectors and showed the imaging capability of the complete device. The major advantage of CZT detectors is the high energy resolution and the high spatial resolution, which are key parameters for Compton Imaging. However, our measurements at the proton beam accelerator facility KVI in Groningen (Netherlands) disclosed a spectrum of prompt gamma rays under proton irradiation up to 4.4 MeV. As CZT detectors of 5 mm thickness do not efficiently absorb photons in such energy ranges, another absorption, based on a Siemens LSO block detector is added behind CZT1. This setup provides a higher absorption probability of high energy photons. With a size of 5.2 cm x 5.2 cm x 2.0 cm, this scintillation detector further increases the angular acceptance of Compton scattered photons due to geometric size. (authors)

  17. Driver hand-held cellular phone use: a four-year analysis.

    Science.gov (United States)

    Eby, David W; Vivoda, Jonathon M; St Louis, Renée M

    2006-01-01

    The use of hand-held cellular (mobile) phones while driving has stirred more debate, passion, and research than perhaps any other traffic safety issue in the past several years. There is ample research showing that the use of either hand-held or hands-free cellular phones can lead to unsafe driving patterns. Whether or not these performance deficits increase the risk of crash is difficult to establish, but recent studies are beginning to suggest that cellular phone use elevates crash risk. The purpose of this study was to assess changes in the rate of hand-held cellular phone use by motor-vehicle drivers on a statewide level in Michigan. This study presents the results of 13 statewide surveys of cellular phone use over a 4-year period. Hand-held cellular phone use data were collected through direct observation while vehicles were stopped at intersections and freeway exit ramps. Data were weighted to be representative of all drivers traveling during daylight hours in Michigan. The study found that driver hand-held cellular phone use has more than doubled between 2001 and 2005, from 2.7% to 5.8%. This change represents an average increase of 0.78 percentage points per year. The 5.8% use rate observed in 2005 means that at any given daylight hour, around 36,550 drivers were conversing on cellular phones while driving on Michigan roadways. The trend line fitted to these data predicts that by the year 2010, driver hand-held cellular phone use will be around 8.6%, or 55,000 drivers at any given daylight hour. These results make it clear that cellular phone use while driving will continue to be an important traffic safety issue, and highlight the importance of continued attempts to generate new ways of alleviating this potential hazard.

  18. NMS Prototype development final report

    International Nuclear Information System (INIS)

    Lepetich, J.E.

    1993-01-01

    Program for development of NMS prototype for LAMPF consisted of 5 tasks: crystal procurement specification, inspection/evaluation of CsI crystals, design/fabrication of crystal housing, design/fabrication of PMT shields, and packaging of crystals in the housing

  19. EUSO-TA prototype telescope

    Energy Technology Data Exchange (ETDEWEB)

    Bisconti, Francesca, E-mail: francesca.bisconti@kit.edu

    2016-07-11

    EUSO-TA is one of the prototypes developed for the JEM-EUSO project, a space-based large field-of-view telescope to observe the fluorescence light emitted by cosmic ray air showers in the atmosphere. EUSO-TA is a ground-based prototype located at the Telescope Array (TA) site in Utah, USA, where an Electron Light Source and a Central Laser Facility are installed. The purpose of the EUSO-TA project is to calibrate the prototype with the TA fluorescence detector in presence of well-known light sources and cosmic ray air showers. In 2015, the detector started the first measurements and tests using the mentioned light sources have been performed successfully. A first cosmic ray candidate has been observed, as well as stars of different magnitude and color index. Since Silicon Photo-Multipliers (SiPMs) are very promising for fluorescence telescopes of next generation, they are under consideration for the realization of a new prototype of EUSO Photo Detector Module (PDM). The response of this sensor type is under investigation through simulations and laboratory experimentation.

  20. The OPAL vertex detector prototype

    International Nuclear Information System (INIS)

    Roney, J.M.; Armitage, J.C.; Carnegie, R.K.; Giles, G.L.; Hemingway, R.J.; McPherson, A.C.; Pinfold, J.L.; Waterhouse, J.; Godfrey, L.; Hargrove, C.K.

    1989-01-01

    The prototype test results of a high resolution charged particle tracking detector are reported. The detector is designed to measure vertex topologies of particles produced in the e + e - collisions of the OPAL experiment at LEP. The OPAL vertex detector is a 1 m long, 0.46 m diameter cylindrical drift chamber consisting of an axial and stereo layer each of which is divided into 36 jet cells. A prototype chamber containing four axial and two stereo cells was studied using a pion test beam at CERN. The studies examined the prototype under a variety of operating conditions. An r-Φ resolution of 60 μm was obtained when the chamber was operated with argon (50%)-ethane (50%) at 3.75 bar, and when CO 2 (80%)-isobutane (20%) at 2.5 bar was used a 25 μm resolution was achieved. A z measurement using end-to-end time difference has a resolution of 3.5 cm. The details of these prototype studies are discussed in this paper. (orig.)

  1. Rapid Prototyping Enters Mainstream Manufacturing.

    Science.gov (United States)

    Winek, Gary

    1996-01-01

    Explains rapid prototyping, a process that uses computer-assisted design files to create a three-dimensional object automatically, speeding the industrial design process. Five commercially available systems and two emerging types--the 3-D printing process and repetitive masking and depositing--are described. (SK)

  2. Encapsulation of polymer photovoltaic prototypes

    DEFF Research Database (Denmark)

    Krebs, Frederik C

    2006-01-01

    A simple and efficient method for the encapsulation of polymer and organic photovoltaic prototypes is presented. The method employs device preparation on glass substrates with subsequent sealing using glass fiber reinforced thermosetting epoxy (prepreg) against a back plate. The method allows...

  3. EUSO-TA prototype telescope

    Science.gov (United States)

    Bisconti, Francesca; JEM-EUSO Collaboration

    2016-07-01

    EUSO-TA is one of the prototypes developed for the JEM-EUSO project, a space-based large field-of-view telescope to observe the fluorescence light emitted by cosmic ray air showers in the atmosphere. EUSO-TA is a ground-based prototype located at the Telescope Array (TA) site in Utah, USA, where an Electron Light Source and a Central Laser Facility are installed. The purpose of the EUSO-TA project is to calibrate the prototype with the TA fluorescence detector in presence of well-known light sources and cosmic ray air showers. In 2015, the detector started the first measurements and tests using the mentioned light sources have been performed successfully. A first cosmic ray candidate has been observed, as well as stars of different magnitude and color index. Since Silicon Photo-Multipliers (SiPMs) are very promising for fluorescence telescopes of next generation, they are under consideration for the realization of a new prototype of EUSO Photo Detector Module (PDM). The response of this sensor type is under investigation through simulations and laboratory experimentation.

  4. Facial Prototype Formation in Children.

    Science.gov (United States)

    Inn, Donald; And Others

    This study examined memory representation as it is exhibited in young children's formation of facial prototypes. In the first part of the study, researchers constructed images of faces using an Identikit that provided the features of hair, eyes, mouth, nose, and chin. Images were varied systematically. A series of these images, called exemplar…

  5. A handheld support system to facilitate stereological measurements and mapping of branching structures

    DEFF Research Database (Denmark)

    Gardi, J.E.; Wulfsohn, Dvora-Laiô; Nyengaard, J.R.

    2007-01-01

    specifications, software and Graphical User Interface (GUI) development, functionality and application of the handheld system using four examples: (1) sampling monkey lung bronchioles for estimation of diameter and wall thickness (2) sampling rat kidney for estimating number of arteries and arterioles......‘BranchSampler' is a system for computer-assisted manual stereology written for handheld devices running Windows CE. The system has been designed specifically to streamline data collection and optimize sampling of tree-like branching structures, with particular aims of reducing user errors, saving...

  6. Standardization from a benchtop to a handheld NIR spectrometer using mathematically mixed NIR spectra to determine fuel quality parameters

    DEFF Research Database (Denmark)

    da Silva, Neirivaldo Cavalcante; Cavalcanti, Claudia Jessica; Honorato, Fernanda Araujo

    2017-01-01

    spectral responses of fuel samples (gasoline and biodiesel blends) from a high-resolution benchtop Frontier FT-NIR (PerkinElmer) spectrometer and a handheld MicroNIR™1700 (JDSU). These virtual standards can be created by mathematically mixing spectra from the pure solvents present in gasoline or diesel...... to the handheld MicroNIR using virtual standards as transfer samples...

  7. Validity of maximal isometric knee extension strength measurements obtained via belt-stabilized hand-held dynamometry in healthy adults.

    Science.gov (United States)

    Ushiyama, Naoko; Kurobe, Yasushi; Momose, Kimito

    2017-11-01

    [Purpose] To determine the validity of knee extension muscle strength measurements using belt-stabilized hand-held dynamometry with and without body stabilization compared with the gold standard isokinetic dynamometry in healthy adults. [Subjects and Methods] Twenty-nine healthy adults (mean age, 21.3 years) were included. Study parameters involved right side measurements of maximal isometric knee extension strength obtained using belt-stabilized hand-held dynamometry with and without body stabilization and the gold standard. Measurements were performed in all subjects. [Results] A moderate correlation and fixed bias were found between measurements obtained using belt-stabilized hand-held dynamometry with body stabilization and the gold standard. No significant correlation and proportional bias were found between measurements obtained using belt-stabilized hand-held dynamometry without body stabilization and the gold standard. The strength identified using belt-stabilized hand-held dynamometry with body stabilization may not be commensurate with the maximum strength individuals can generate; however, it reflects such strength. In contrast, the strength identified using belt-stabilized hand-held dynamometry without body stabilization does not reflect the maximum strength. Therefore, a chair should be used to stabilize the body when performing measurements of maximal isometric knee extension strength using belt-stabilized hand-held dynamometry in healthy adults. [Conclusion] Belt-stabilized hand-held dynamometry with body stabilization is more convenient than the gold standard in clinical settings.

  8. Prototype diagnosis of psychiatric syndromes

    Science.gov (United States)

    WESTEN, DREW

    2012-01-01

    The method of diagnosing patients used since the early 1980s in psychiatry, which involves evaluating each of several hundred symptoms for their presence or absence and then applying idiosyncratic rules for combining them for each of several hundred disorders, has led to great advances in research over the last 30 years. However, its problems have become increasingly apparent, particularly for clinical practice. An alternative approach, designed to maximize clinical utility, is prototype matching. Instead of counting symptoms of a disorder and determining whether they cross an arbitrary cutoff, the task of the diagnostician is to gauge the extent to which a patient’s clinical presentation matches a paragraph-length description of the disorder using a simple 5-point scale, from 1 (“little or no match”) to 5 (“very good match”). The result is both a dimensional diagnosis that captures the extent to which the patient “has” the disorder and a categorical diagnosis, with ratings of 4 and 5 corresponding to presence of the disorder and a rating of 3 indicating “subthreshold” or “clinically significant features”. The disorders and criteria woven into the prototypes can be identified empirically, so that the prototypes are both scientifically grounded and clinically useful. Prototype diagnosis has a number of advantages: it better captures the way humans naturally classify novel and complex stimuli; is clinically helpful, reliable, and easy to use in everyday practice; facilitates both dimensional and categorical diagnosis and dramatically reduces the number of categories required for classification; allows for clinically richer, empirically derived, and culturally relevant classification; reduces the gap between research criteria and clinical knowledge, by allowing clinicians in training to learn a small set of standardized prototypes and to develop richer mental representations of the disorders over time through clinical experience; and can help

  9. Prototype Effect and the Persuasiveness of Generalizations.

    Science.gov (United States)

    Dahlman, Christian; Sarwar, Farhan; Bååth, Rasmus; Wahlberg, Lena; Sikström, Sverker

    An argument that makes use of a generalization activates the prototype for the category used in the generalization. We conducted two experiments that investigated how the activation of the prototype affects the persuasiveness of the argument. The results of the experiments suggest that the features of the prototype overshadow and partly overwrite the actual facts of the case. The case is, to some extent, judged as if it had the features of the prototype instead of the features it actually has. This prototype effect increases the persuasiveness of the argument in situations where the audience finds the judgment more warranted for the prototype than for the actual case (positive prototype effect), but decreases persuasiveness in situations where the audience finds the judgment less warranted for the prototype than for the actual case (negative prototype effect).

  10. Supporting Active User Involvment in Prototyping

    DEFF Research Database (Denmark)

    Grønbæk, Kaj

    1990-01-01

    The term prototyping has in recent years become a buzzword in both research and practice of system design due to a number of claimed advantages of prototyping techniques over traditional specification techniques. In particular it is often stated that prototyping facilitates the users' involvement...... in the development process. But prototyping does not automatically imply active user involvement! Thus a cooperative prototyping approach aiming at involving users actively and creatively in system design is proposed in this paper. The key point of the approach is to involve users in activities that closely couple...... development of prototypes to early evaluation of prototypes in envisioned use situations. Having users involved in such activities creates new requirements for tool support. Tools that support direct manipulation of prototypes and simulation of behaviour have shown promise for cooperative prototyping...

  11. Prototyping of user interfaces for mobile applications

    CERN Document Server

    Bähr, Benjamin

    2017-01-01

    This book investigates processes for the prototyping of user interfaces for mobile apps, and describes the development of new concepts and tools that can improve the prototype driven app development in the early stages. It presents the development and evaluation of a new requirements catalogue for prototyping mobile app tools that identifies the most important criteria such tools should meet at different prototype-development stages. This catalogue is not just a good point of orientation for designing new prototyping approaches, but also provides a set of metrics for a comparing the performance of alternative prototyping tools. In addition, the book discusses the development of Blended Prototyping, a new approach for prototyping user interfaces for mobile applications in the early and middle development stages, and presents the results of an evaluation of its performance, showing that it provides a tool for teamwork-oriented, creative prototyping of mobile apps in the early design stages.

  12. A Comparison Of GADRAS Simulated And Measured Gamma Ray Spectra

    International Nuclear Information System (INIS)

    Jeffcoat, R.; Salaymeh, S.

    2010-01-01

    Gamma-ray radiation detection systems are continuously being developed and improved for detecting the presence of radioactive material and for identifying isotopes present. Gamma-ray spectra, from many different isotopes and in different types and thicknesses of attenuation material and matrixes, are needed to evaluate the performance of these devices. Recently, a test and evaluation exercise was performed by the Savannah River National Laboratory that required a large number of gamma-ray spectra. Simulated spectra were used for a major portion of the testing in order to provide a pool of data large enough for the results to be statistically significant. The test data set was comprised of two types of data, measured and simulated. The measured data were acquired with a hand-held Radioisotope Identification Device (RIID) and simulated spectra were created using Gamma Detector Response and Analysis Software (GADRAS, Mitchell and Mattingly, Sandia National Laboratory). GADRAS uses a one-dimensional discrete ordinate calculation to simulate gamma-ray spectra. The measured and simulated spectra have been analyzed and compared. This paper will discuss the results of the comparison and offer explanations for spectral differences.

  13. Gamma camera

    International Nuclear Information System (INIS)

    Tschunt, E.; Platz, W.; Baer, U.; Heinz, L.

    1978-01-01

    A gamma camera has a plurality of exchangeable collimators, one of which is mounted in the ray inlet opening of the camera, while the others are placed on separate supports. The supports are swingably mounted upon a column one above the other through about 90 0 to a collimator exchange position. Each of the separate supports is swingable to a vertically aligned position, with limiting of the swinging movement and positioning of the support at the desired exchange position. The collimators are carried on the supports by means of a series of vertically disposed coil springs. Projections on the camera are movable from above into grooves of the collimator at the exchange position, whereupon the collimator is turned so that it is securely prevented from falling out of the camera head

  14. Gamma radiation detectors for safeguards applications

    International Nuclear Information System (INIS)

    Carchon, R.; Moeslinger, M.; Bourva, L.; Bass, C.; Zendel, M.

    2007-01-01

    The IAEA uses extensively a variety of gamma radiation detectors to verify nuclear material. These detectors are part of standardized spectrometry systems: germanium detectors for High-Resolution Gamma Spectrometry (HRGS); Cadmium Zinc Telluride (CZT) detectors for Room Temperature Gamma Spectrometry (RTGS); and NaI(Tl) detectors for Low Resolution Gamma Spectrometry (LRGS). HRGS with high-purity Germanium (HpGe) detectors cooled by liquid nitrogen is widely used in nuclear safeguards to verify the isotopic composition of plutonium or uranium in non-irradiated material. Alternative cooling systems have been evaluated and electrically cooled HpGe detectors show a potential added value, especially for unattended measurements. The spectrometric performance of CZT detectors, their robustness and simplicity are key to the successful verification of irradiated materials. Further development, such as limiting the charge trapping effects in CZT to provide improved sensitivity and energy resolution are discussed. NaI(Tl) detectors have many applications-specifically in hand-held radioisotope identification devices (RID) which are used to detect the presence of radioactive material where a lower resolution is sufficient, as they benefit from a generally higher sensitivity. The Agency is also continuously involved in the review and evaluation of new and emerging technologies in the field of radiation detection such as: Peltier-cooled CdTe detectors; semiconductor detectors operating at room temperature such as HgI 2 and GaAs; and, scintillator detectors using glass fibres or LaBr 3 . A final conclusion, proposing recommendations for future action, is made

  15. A gamma beam profile imager for ELI-NP Gamma Beam System

    Science.gov (United States)

    Cardarelli, P.; Paternò, G.; Di Domenico, G.; Consoli, E.; Marziani, M.; Andreotti, M.; Evangelisti, F.; Squerzanti, S.; Gambaccini, M.; Albergo, S.; Cappello, G.; Tricomi, A.; Veltri, M.; Adriani, O.; Borgheresi, R.; Graziani, G.; Passaleva, G.; Serban, A.; Starodubtsev, O.; Variola, A.; Palumbo, L.

    2018-06-01

    The Gamma Beam System of ELI-Nuclear Physics is a high brilliance monochromatic gamma source based on the inverse Compton interaction between an intense high power laser and a bright electron beam with tunable energy. The source, currently being assembled in Magurele (Romania), is designed to provide a beam with tunable average energy ranging from 0.2 to 19.5 MeV, rms energy bandwidth down to 0.5% and flux of about 108 photons/s. The system includes a set of detectors for the diagnostic and complete characterization of the gamma beam. To evaluate the spatial distribution of the beam a gamma beam profile imager is required. For this purpose, a detector based on a scintillator target coupled to a CCD camera was designed and a prototype was tested at INFN-Ferrara laboratories. A set of analytical calculations and Monte Carlo simulations were carried out to optimize the imager design and evaluate the performance expected with ELI-NP gamma beam. In this work the design of the imager is described in detail, as well as the simulation tools used and the results obtained. The simulation parameters were tuned and cross-checked with the experimental measurements carried out on the assembled prototype using the beam from an x-ray tube.

  16. Design in action: From prototyping by demonstration to cooperative prototyping

    DEFF Research Database (Denmark)

    Bødker, Susanne; Grønbæk, Kaj

    1991-01-01

    ... the development of any computer-based system will have to proceed in a cycle from design to experience and back again. It is impossible to anticipate all of the relevant breakdown and their domains. They emerge gradually in practice. Winograd and Flores, 1986. p.171 Some time ago we worked wi...... with a group of dental assistants, designing a prototype case record system to explore the possibility of using computer support in public dental clinics. ...

  17. Energy Cost of Active and Sedentary Music Video Games: Drum and Handheld Gaming vs. Walking and Sitting.

    Science.gov (United States)

    Miranda, Edwin; Overstreet, Brittany S; Fountain, William A; Gutierrez, Vincent; Kolankowski, Michael; Overstreet, Matthew L; Sapp, Ryan M; Wolff, Christopher A; Mazzetti, Scott A

    2017-01-01

    To compare energy expenditure during and after active and handheld video game drumming compared to walking and sitting. Ten experienced, college-aged men performed four protocols (one per week): no-exercise seated control (CTRL), virtual drumming on a handheld gaming device (HANDHELD), active drumming on drum pads (DRUM), and walking on a treadmill at ~30% of VO 2max (WALK). Protocols were performed after an overnight fast, and expired air was collected continuously during (30min) and after (30min) exercise. DRUM and HANDHELD song lists, day of the week, and time of day were identical for each participant. Significant differences (p DRUM > HANDHELD. No significant differences in the rates of energy expenditure among groups during recovery were observed. Total energy expenditure was significantly greater (p < 0.05) during WALK (149.5 ± 30.6 kcal) compared to DRUM (118.7 ± 18.8 kcal) and HANDHELD (44.9±11.6 kcal), and greater during DRUM compared to HANDHELD. Total energy expenditure was not significantly different between HANDHELD (44.9 ± 11.6 kcal) and CTRL (38.2 ± 6.0 kcal). Active video game drumming at expert-level significantly increased energy expenditure compared to handheld, but it hardly met moderate-intensity activity standards, and energy expenditure was greatest during walking. Energy expenditure with handheld video game drumming was not different from no-exercise control. Thus, traditional aerobic exercise remains at the forefront for achieving the minimum amount and intensity of physical activity for health, individuals desiring to use video games for achieving weekly physical activity recommendations should choose games that require significant involvement of lower-body musculature, and time spent playing sedentary games should be a limited part of an active lifestyle.

  18. Handheld single photon emission computed tomography (handheld SPECT) navigated video-assisted thoracoscopic surgery of computer tomography-guided radioactively marked pulmonary lesions.

    Science.gov (United States)

    Müller, Joachim; Putora, Paul Martin; Schneider, Tino; Zeisel, Christoph; Brutsche, Martin; Baty, Florent; Markus, Alexander; Kick, Jochen

    2016-09-01

    Radioactive marking can be a valuable extension to minimally invasive surgery. The technique has been clinically applied in procedures involving sentinel lymph nodes, parathyroidectomy as well as interventions in thoracic surgery. Improvements in equipment and techniques allow one to improve the limits. Pulmonary nodules are frequently surgically removed for diagnostic or therapeutic reasons; here video-assisted thoracoscopic surgery (VATS) is the preferred technique. VATS might be impossible with nodules that are small or located deep in the lung. In this study, we examined the clinical application and safety of employing the newly developed handheld single photon emission tomography (handheld SPECT) device in combination with CT-guided radioactive marking of pulmonary nodules. In this pilot study, 10 subjects requiring surgical resection of a pulmonary nodule were included. The technique involved CT-guided marking of the target nodule with a 20-G needle, with subsequent injection of 25-30 MBq (effective: 7-14 MBq) Tc-99m MAA (Macro Albumin Aggregate). Quality control was made with conventional SPECT-CT to confirm the correct localization and exclude possible complications related to the puncture procedure. VATS was subsequently carried out using the handheld SPECT to localize the radioactivity intraoperatively and therefore the target nodule. A 3D virtual image was superimposed on the intraoperative visual image for surgical guidance. In 9 of the 10 subjects, the radioactive application was successfully placed directly in or in the immediate vicinity of the target nodule. The average size of the involved nodules was 9 mm (range 4-15). All successfully marked nodules were subsequently completely excised (R0) using VATS. The procedure was well tolerated. An asymptomatic clinically insignificant pneumothorax occurred in 5 subjects. Two subjects were found to have non-significant discrete haemorrhage in the infiltration canal of the needle. In a single subject, the

  19. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 2 discusses the following topics: Fuel Rod Extraction System Test Results and Analysis Reports and Clamping Table Test Results and Analysis Reports

  20. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 1 discusses the following topics: the background of the project; test program description; summary of tests and test results; problem evaluation; functional requirements confirmation; recommendations; and completed test documentation for tests performed in Phase 3

  1. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 9 discusses the following topics: Integrated System Normal Operations Test Results and Analysis Report; Integrated System Off-Normal Operations Test Results and Analysis Report; and Integrated System Maintenance Operations Test Results and Analysis Report

  2. Prototype of sun projector device

    Science.gov (United States)

    Ihsan; Dermawan, B.

    2016-11-01

    One way to introduce astronomy to public, including students, can be handled by solar observation. The widely held device for this purpose is coelostat and heliostat. Besides using filter attached to a device such as telescope, it is safest to use indirect way for observing the Sun. The main principle of the indirect way is deflecting the sun light and projecting image of the sun on a screen. We design and build a simple and low-cost astronomical device, serving as a supplement to increase public service, especially for solar observation. Without using any digital and intricate supporting equipment, people can watch and relish image of the Sun in comfortable condition, i.e. in a sheltered or shady place. Here we describe a design and features of our prototype of the device, which still, of course, has some limitations. In the future, this prototype can be improved for more efficient and useful applications.

  3. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 8 discusses Control System SOT Tests Results and Analysis Report. This is a continuation of Book 7

  4. Prototype and proposed ISABELLE dipoles

    International Nuclear Information System (INIS)

    McInturff, A.D.; Sampson, W.B.; Robins, K.E.; Dahl, P.F.; Damm, R.

    1977-01-01

    Data are presented on the latest dipole prototypes to update the operational parameters possible for ISABELLE. This data base will constantly expand until the start of construction of the storage rings. The data will include field quality, stray field magnitudes, quench temperature and propagation times, protection capabilities singly and in multiple units, maximum central fields obtained and training behavior. Performance of the dipoles versus temperature and mode of refrigeration will be discussed. The single layer cosine theta turns distribution coils' parameters are better than those required for the operation of the 200 x 200 GeV version of ISABELLE. The double layer prototype has exceeded the magnetic field performance and two dimensional quality of field needed for the 400 x 400 GeV version of ISABELLE

  5. Prototypical Rod Construction Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 3 discusses the following topics: Downender Test Results and Analysis Report; NFBC Canister Upender Test Results and Analysis Report; Fuel Assembly Handling Fixture Test Results and Analysis Report; and Fuel Canister Upender Test Results and Analysis Report

  6. Rapid mask prototyping for microfluidics.

    Science.gov (United States)

    Maisonneuve, B G C; Honegger, T; Cordeiro, J; Lecarme, O; Thiry, T; Fuard, D; Berton, K; Picard, E; Zelsmann, M; Peyrade, D

    2016-03-01

    With the rise of microfluidics for the past decade, there has come an ever more pressing need for a low-cost and rapid prototyping technology, especially for research and education purposes. In this article, we report a rapid prototyping process of chromed masks for various microfluidic applications. The process takes place out of a clean room, uses a commercially available video-projector, and can be completed in less than half an hour. We quantify the ranges of fields of view and of resolutions accessible through this video-projection system and report the fabrication of critical microfluidic components (junctions, straight channels, and curved channels). To exemplify the process, three common devices are produced using this method: a droplet generation device, a gradient generation device, and a neuro-engineering oriented device. The neuro-engineering oriented device is a compartmentalized microfluidic chip, and therefore, required the production and the precise alignment of two different masks.

  7. Prototyping the PANDA Barrel DIRC

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, C., E-mail: C.Schwarz@gsi.de [GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt (Germany); Kalicy, G.; Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Hohler, R.; Kumawat, H.; Lehmann, D.; Lewandowski, B.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwiening, J.; Traxler, M.; Zühlsdorf, M. [GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt (Germany); Dodokhov, V.Kh. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Britting, A.; Eyrich, W.; Lehmann, A. [Friedrich Alexander-University of Erlangen-Nuremberg, Erlangen (Germany); and others

    2014-12-01

    The design of the Barrel DIRC detector for the future PANDA experiment at FAIR contains several important improvements compared to the successful BABAR DIRC, such as focusing and fast timing. To test those improvements as well as other design options a prototype was build and successfully tested in 2012 with particle beams at CERN. The prototype comprises a radiator bar, focusing lens, mirror, and a prism shaped expansion volume made of synthetic fused silica. An array of micro-channel plate photomultiplier tubes measures the location and arrival time of the Cherenkov photons with sub-nanosecond resolution. The development of a fast reconstruction algorithm allowed to tune construction details of the detector setup with test beam data and Monte-Carlo simulations.

  8. Customer-experienced rapid prototyping

    Science.gov (United States)

    Zhang, Lijuan; Zhang, Fu; Li, Anbo

    2008-12-01

    In order to describe accurately and comprehend quickly the perfect GIS requirements, this article will integrate the ideas of QFD (Quality Function Deployment) and UML (Unified Modeling Language), and analyze the deficiency of prototype development model, and will propose the idea of the Customer-Experienced Rapid Prototyping (CE-RP) and describe in detail the process and framework of the CE-RP, from the angle of the characteristics of Modern-GIS. The CE-RP is mainly composed of Customer Tool-Sets (CTS), Developer Tool-Sets (DTS) and Barrier-Free Semantic Interpreter (BF-SI) and performed by two roles of customer and developer. The main purpose of the CE-RP is to produce the unified and authorized requirements data models between customer and software developer.

  9. Audiovisual Presentations on a Handheld PC are Preferred As an Educational Tool by NICU Parents.

    Science.gov (United States)

    Alur, P; Cirelli, J; Goodstein, M; Bell, T; Liss, J

    2010-01-01

    Health literacy is critical for understanding complex medical problems and necessary for the well being of the patient. Printed educational materials (PM) have limitations in explaining the dynamics of a disease process. Multimedia formats may be useful for enhancing the educational process. To evaluate whether a printed format or animation with commentary on a handheld personal computer (PC) is preferred as an educational tool by parents of a baby in the NICU. PARENTS EVALUATED TWO FORMATS: A 1-page illustrated document from the American Heart Association explaining patent ductus arteriosus (PDA) and animation with commentary on a handheld PC that explained the physiology of PDA in 1 minute. The reading grade level of the PM was 8.6 versus 18.6 for the audio portion of the animated presentation. Parents viewed each format and completed a four-item questionnaire. Parents rated both formats and indicated their preference as printed, animation, or both. Forty-six parents participated in the survey. Parents preferred animation over PM (50% vs. 17.4%. p = 0.02); 39.1% expressed that the animation was excellent; whereas 4.3% expressed that the PM was excellent (p0.05). Parents preferred animation on a small screen handheld PC despite a much higher language level. Because handheld PCs are portable and inexpensive, they can be used effectively at the bedside with low-cost animation to enhance understanding of complex disease conditions.

  10. How to use hand-held computers to evaluate wood drying.

    Science.gov (United States)

    Howard N. Rosen; Darrell S. Martin

    1985-01-01

    Techniques have been developed to evaluate end generate wood drying curves with hand-held computers (3-5K memory). Predictions of time to dry to a specific moisture content, drying rates, and other characteristics of wood drying curves can be made. The paper describes the development of programs and illustrates their use.

  11. Epidemiology of Handheld Cell Phone Use While Driving: A Study from a South Indian City

    Directory of Open Access Journals (Sweden)

    Sumanth Mallikarjuna Majgi

    2018-01-01

    Full Text Available Background: Using cell phones while driving contribute to distractions which can potentially cause minor or major road traffic injuries and also stress among other drivers. With this background, the study was done to ascertain the proportion of handheld cell phone use while driving among road users in Mysore city and also patterns of the use by the day of week, type of road, and type of vehicle. Methods: The study was conducted in Mysore, Karnataka, India. Four stretches of roads were observed thrice daily for 1 week. The total number of vehicles passing through the stretch and the number and characteristics of drivers using hand-held cell was noted. Pearson's Chi-square test was used to ascertain the significance of the difference in proportions. Results: The overall proportion of cell phone users was calculated as 1.41/100 vehicles. The observed use of handheld cell phones was 1.78 times higher on nonbusy roads than busy roads (Χ2 = 25.79, P < 0.0001. More than 50% of the handheld phone users were driving a two wheeler, the proportion being 50.5% in busy roads, and 67% in nonbusy roads. There was no difference in the proportion of cell phone use by time of the day or across different days of the week. Conclusions: The proportion of drivers who use cell phones is found to be relatively lower, and use of cell phones was higher on nonbusy roads.

  12. 75 FR 10502 - In the Matter of Certain Electronic Devices, Including Handheld Wireless Communications Devices...

    Science.gov (United States)

    2010-03-08

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-667; Investigation No. 337-TA-673] In the Matter of Certain Electronic Devices, Including Handheld Wireless Communications Devices; Notice of... Entirety AGENCY: U.S. International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that...

  13. 76 FR 22918 - In the Matter of Certain Handheld Electronic Computing Devices, Related Software, and Components...

    Science.gov (United States)

    2011-04-25

    ... INTERNATIONAL TRADE COMMISSION [Inv. No. 337-TA-769] In the Matter of Certain Handheld Electronic.... International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that a complaint was filed with the U.S. International Trade Commission on March 21, 2011, under section 337 of the Tariff Act of 1930...

  14. A Fresh Look at the Crystal Violet Lab with Handheld Camera Colorimetry

    Science.gov (United States)

    Knutson, Theodore R.; Knutson, Cassandra M.; Mozzetti, Abbie R.; Campos, Antonio R.; Haynes, Christy L.; Penn, R. Lee

    2015-01-01

    Chemical kinetic experiments to determine rate laws are common in high school and college chemistry courses. For reactions involving a color change, rate laws can be determined experimentally using spectrophotometric or colorimetric equipment though this equipment can be cost prohibitive. Previous work demonstrated that inexpensive handheld camera…

  15. The Xsense project: The application of an intelligent sensor array for high sensitivity handheld explosives detectors

    DEFF Research Database (Denmark)

    Kostesha, Natalie; Schmidt, Michael Stenbæk; Bosco, Filippo

    2011-01-01

    Multiple independent sensors are used in security and military applications in order to increase sensitivity, selectivity and data reliability. The Xsense project has been initiated at the Technical University of Denmark in collaboration with a number of partners in an effort to produce a handheld...

  16. Survey reveals public open to ban on hand-held cell phone use and texting.

    Science.gov (United States)

    2013-01-01

    A study performed by the Bureau of Transportation Statistics (BTS) reveals that the public is open to a ban on hand-held cell phone use while driving. The study is based on data from 2009s Omnibus Household Survey (OHS), which is administered by B...

  17. Applying Hand-Held 3D Printing Technology to the Teaching of VSEPR Theory

    Science.gov (United States)

    Dean, Natalie L.; Ewan, Corrina; McIndoe, J. Scott

    2016-01-01

    The use of hand-held 3D printing technology provides a unique and engaging approach to learning VSEPR theory by enabling students to draw three-dimensional depictions of different molecular geometries, giving them an appreciation of the shapes of the building blocks of complex molecular structures. Students are provided with 3D printing pens and…

  18. Xsense: using nanotechnology to combine detection methods for high sensitivity handheld explosives detectors

    DEFF Research Database (Denmark)

    Schmidt, Michael Stenbæk; Kostesha, Natalie; Bosco, Filippo

    2010-01-01

    In an effort to produce a handheld explosives sensor the Xsense project has been initiated at the Technical University of Denmark in collaboration with a number of partners. Using micro- and nano technological approaches it will be attempted to integrate four detection principles into a single de...

  19. Radiation safety evaluation of a hand-held, battery operated image intensifier

    International Nuclear Information System (INIS)

    Wilson, O.J.; Young, B.F.

    1987-01-01

    A portable, hand-held, fluoroscopic unit intended for medical and industrial use was tested to verify the claim of the manufacturers that the radiation doses to the patient and user are low, and comparable to those received from standard radiographic procedures. The first claim was substantiated but not the second. A number of concerns arising from the use of this unit are discussed

  20. Clinical translation of handheld optical coherence tomography: practical considerations and recent advancements

    Science.gov (United States)

    Monroy, Guillermo L.; Won, Jungeun; Spillman, Darold R.; Dsouza, Roshan; Boppart, Stephen A.

    2017-12-01

    Since the inception of optical coherence tomography (OCT), advancements in imaging system design and handheld probes have allowed for numerous advancements in disease diagnostics and characterization of the structural and optical properties of tissue. OCT system developers continue to reduce form factor and cost, while improving imaging performance (speed, resolution, etc.) and flexibility for applicability in a broad range of fields, and nearly every clinical specialty. An extensive array of components to construct customized systems has also become available, with a range of commercial entities that produce high-quality products, from single components to full systems, for clinical and research use. Many advancements in the development of these miniaturized and portable systems can be linked back to a specific challenge in academic research, or a clinical need in medicine or surgery. Handheld OCT systems are discussed and explored for various applications. Handheld systems are discussed in terms of their relative level of portability and form factor, with mention of the supporting technologies and surrounding ecosystem that bolstered their development. Additional insight from our efforts to implement systems in several clinical environments is provided. The trend toward well-designed, efficient, and compact handheld systems paves the way for more widespread adoption of OCT into point-of-care or point-of-procedure applications in both clinical and commercial settings.

  1. Detection of fecal contamination on beef meat surfaces using handheld fluorescence imaging device (HFID)

    Science.gov (United States)

    Current meat inspection in slaughter plants, for food safety and quality attributes including potential fecal contamination, is conducted through by visual examination human inspectors. A handheld fluorescence-based imaging device (HFID) was developed to be an assistive tool for human inspectors by ...

  2. Learning Motivation and Adaptive Video Caption Filtering for EFL Learners Using Handheld Devices

    Science.gov (United States)

    Hsu, Ching-Kun

    2015-01-01

    The aim of this study was to provide adaptive assistance to improve the listening comprehension of eleventh grade students. This study developed a video-based language learning system for handheld devices, using three levels of caption filtering adapted to student needs. Elementary level captioning excluded 220 English sight words (see Section 1…

  3. Acute pain management efficiency improves with point-of-care handheld electronic billing system.

    Science.gov (United States)

    Fahy, Brenda G

    2009-02-01

    Technology advances continue to impact patient care and physician workflow. To enable more efficient performance of billing activities, a point-of-care (POC) handheld computer technology replaced a paper-based system on an acute pain management service. Using a handheld personal digital assistant (PDA) and software from MDeverywhere (MDe, MDeverywhere, Long Island, NY), we performed a 1-yr prospective observational study of an anesthesiology acute pain management service billings and collections. Seventeen anesthesiologists providing billable acute pain services were trained and entered their charges on a PDA. Twelve months of data, just before electronic implementation (pre-elec), were compared to a 12-m period after implementation (post-elec). The total charges were 4883 for 890 patients pre-elec and 5368 for 1128 patients post-elec. With adoption of handheld billing, the charge lag days decreased from 29.3 to 7.0 (P billing using PDAs to replace a paper-based billing system improved the collection rate and decreased the number of charge lag days with a positive return on investment. The handheld PDA billing system provided POC support for physicians during their daily clinical (e.g., patient locations, rounding lists) and billing activities, improving workflow.

  4. A Mobile Mixed-Reality Environment for Children's Storytelling Using a Handheld Projector and a Robot

    Science.gov (United States)

    Sugimoto, Masanori

    2011-01-01

    This paper describes a system called GENTORO that uses a robot and a handheld projector for supporting children's storytelling activities. GENTORO differs from many existing systems in that children can make a robot play their own story in a physical space augmented by mixed-reality technologies. Pilot studies have been conducted to clarify the…

  5. Performance Analysis of Nomadic Mobile Services on Multi-homed Handheld Devices

    NARCIS (Netherlands)

    Pawar, P.; van Beijnum, Bernhard J.F.; van Sinderen, Marten J.; Aggarwal, Akshai; De Clercq, Frederic

    2007-01-01

    Compared to their predecessors, the current generation handheld mobile devices possess higher processing power, increased memory and new multi-homing capabilities. These features combined with the widespread acceptance and use of these devices result in a situation where mobile devices are no longer

  6. A Study of the Use of a Handheld Computer Algebra System in Discrete Mathematics

    Science.gov (United States)

    Powers, Robert A.; Allison, Dean E.; Grassl, Richard M.

    2005-01-01

    This study investigated the impact of the TI-92 handheld Computer Algebra System (CAS) on student achievement in a discrete mathematics course. Specifically, the researchers examined the differences between a CAS section and a control section of discrete mathematics on students' in-class examinations. Additionally, they analysed student approaches…

  7. Efficacy of Handheld Electronic Visual Supports to Enhance Vocabulary in Children with ASD

    Science.gov (United States)

    Ganz, Jennifer B.; Boles, Margot B.; Goodwyn, Fara D.; Flores, Margaret M.

    2014-01-01

    Although electronic tools such as handheld computers have become increasingly common throughout society, implementation of such tools to improve skills in individuals with intellectual and developmental disabilities has lagged in the professional literature. However, the use of visual scripts for individuals with disabilities, particularly those…

  8. The Weak Link HP-41C hand-held calculator program

    Science.gov (United States)

    Ross A. Phillips; Penn A. Peters; Gary D. Falk

    1982-01-01

    The Weak Link hand-held calculator program (HP-41C) quickly analyzes a system for logging production and costs. The production equations model conventional chain saw, skidder, loader, and tandemaxle truck operations in eastern mountain areas. Production of each function of the logging system may be determined so that the system may be balanced for minimum cost. The...

  9. DOE's annealing prototype demonstration projects

    International Nuclear Information System (INIS)

    Warren, J.; Nakos, J.; Rochau, G.

    1997-01-01

    One of the challenges U.S. utilities face in addressing technical issues associated with the aging of nuclear power plants is the long-term effect of plant operation on reactor pressure vessels (RPVs). As a nuclear plant operates, its RPV is exposed to neutrons. For certain plants, this neutron exposure can cause embrittlement of some of the RPV welds which can shorten the useful life of the RPV. This RPV embrittlement issue has the potential to affect the continued operation of a number of operating U.S. pressurized water reactor (PWR) plants. However, RPV material properties affected by long-term irradiation are recoverable through a thermal annealing treatment of the RPV. Although a dozen Russian-designed RPVs and several U.S. military vessels have been successfully annealed, U.S. utilities have stated that a successful annealing demonstration of a U.S. RPV is a prerequisite for annealing a licensed U.S. nuclear power plant. In May 1995, the Department of Energy's Sandia National Laboratories awarded two cost-shared contracts to evaluate the feasibility of annealing U.S. licensed plants by conducting an anneal of an installed RPV using two different heating technologies. The contracts were awarded to the American Society of Mechanical Engineers (ASME) Center for Research and Technology Development (CRTD) and MPR Associates (MPR). The ASME team completed its annealing prototype demonstration in July 1996, using an indirect gas furnace at the uncompleted Public Service of Indiana's Marble Hill nuclear power plant. The MPR team's annealing prototype demonstration was scheduled to be completed in early 1997, using a direct heat electrical furnace at the uncompleted Consumers Power Company's nuclear power plant at Midland, Michigan. This paper describes the Department's annealing prototype demonstration goals and objectives; the tasks, deliverables, and results to date for each annealing prototype demonstration; and the remaining annealing technology challenges

  10. Encapsulation of polymer photovoltaic prototypes

    Energy Technology Data Exchange (ETDEWEB)

    Krebs, Frederik C. [The Danish Polymer Centre, RISOE National Laboratory, P.O. Box 49, DK-4000 Roskilde (Denmark)

    2006-12-15

    A simple and efficient method for the encapsulation of polymer and organic photovoltaic prototypes is presented. The method employs device preparation on glass substrates with subsequent sealing using glass fiber reinforced thermosetting epoxy (prepreg) against a back plate. The method allows for transporting oxygen and water sensitive devices outside a glove box environment after sealing and enables sharing of devices between research groups such that efficiency and stability can be evaluated in different laboratories. (author)

  11. Yucca Mountain project prototype testing

    International Nuclear Information System (INIS)

    Hughes, W.T.; Girdley, W.A.

    1990-01-01

    The U.S. DOE is responsible for characterizing the Yucca Mountain site in Nevada to determine its suitability for development as a geologic repository to isolate high-level nuclear waste for at least 10,000 years. This unprecedented task relies in part on measurements made with relatively new methods or applications, such as dry coring and overcoring for studies to be conducted from the land surface and in an underground facility. The Yucca Mountain Project has, since 1988, implemented a program of equipment development and methods development for a broad spectrum of hydrologic, geologic, rock mechanics, and thermomechanical tests planned for use in an Exploratory Shaft during site characterization at the Yucca Mountain site. A second major program was fielded beginning in April 1989 to develop and test methods and equipment for surface drilling to obtain core samples from depth using only air as a circulating medium. The third major area of prototype testing has been during the ongoing development of the Instrumentation/ Data Acquisition System (IDAS), designed to collect and monitor data from down-hole instrumentation in the unsaturated zone, and store and transmit the data to a central archiving computer. Future prototype work is planned for several programs including the application of vertical seismic profiling methods and flume design to characterizing the geology at Yucca Mountain. The major objectives of this prototype testing are to assure that planned Site Characterization testing can be carried out effectively at Yucca Mountain, both in the Exploratory Shaft Facility (ESF), and from the surface, and to avoid potential major failures or delays that could result from the need to re-design testing concepts or equipment. This paper will describe the scope of the Yucca Mountain Project prototype testing programs and summarize results to date. 3 figs

  12. Prototype Morphing Fan Nozzle Demonstrated

    Science.gov (United States)

    Lee, Ho-Jun; Song, Gang-Bing

    2004-01-01

    Ongoing research in NASA Glenn Research Center's Structural Mechanics and Dynamics Branch to develop smart materials technologies for aeropropulsion structural components has resulted in the design of the prototype morphing fan nozzle shown in the photograph. This prototype exploits the potential of smart materials to significantly improve the performance of existing aircraft engines by introducing new inherent capabilities for shape control, vibration damping, noise reduction, health monitoring, and flow manipulation. The novel design employs two different smart materials, a shape-memory alloy and magnetorheological fluids, to reduce the nozzle area by up to 30 percent. The prototype of the variable-area fan nozzle implements an overlapping spring leaf assembly to simplify the initial design and to provide ease of structural control. A single bundle of shape memory alloy wire actuators is used to reduce the nozzle geometry. The nozzle is subsequently held in the reduced-area configuration by using magnetorheological fluid brakes. This prototype uses the inherent advantages of shape memory alloys in providing large induced strains and of magnetorheological fluids in generating large resistive forces. In addition, the spring leaf design also functions as a return spring, once the magnetorheological fluid brakes are released, to help force the shape memory alloy wires to return to their original position. A computerized real-time control system uses the derivative-gain and proportional-gain algorithms to operate the system. This design represents a novel approach to the active control of high-bypass-ratio turbofan engines. Researchers have estimated that such engines will reduce thrust specific fuel consumption by 9 percent over that of fixed-geometry fan nozzles. This research was conducted under a cooperative agreement (NCC3-839) at the University of Akron.

  13. Using prototyping in software development

    OpenAIRE

    Šinkovec, Miha

    2010-01-01

    Today the business system changers faster than the usual conventional cascade life cycle. Because of that, we can conclude, that today's programming system will no longer be presented as the answer to this topic in the developing age of ever changing user requirements. Neither increased performance or higher productivity will decrease the problem. The appropriate solution to this stated problem is prototyping. Instead of building and developing the whole system, we build a module that can...

  14. Iteration and Prototyping in Creating Technical Specifications.

    Science.gov (United States)

    Flynt, John P.

    1994-01-01

    Claims that the development process for computer software can be greatly aided by the writers of specifications if they employ basic iteration and prototyping techniques. Asserts that computer software configuration management practices provide ready models for iteration and prototyping. (HB)

  15. Active case finding strategy for chronic obstructive pulmonary disease with handheld spirometry.

    Science.gov (United States)

    Kim, Joo Kyung; Lee, Chang Min; Park, Ji Young; Kim, Joo Hee; Park, Sung-Hoon; Jang, Seung Hun; Jung, Ki-Suck; Yoo, Kwang Ha; Park, Yong Bum; Rhee, Chin Kook; Kim, Deog Kyeom; Hwang, Yong Il

    2016-12-01

    The early detection and diagnosis of chronic obstructive pulmonary disease (COPD) is critical to providing appropriate and timely treatment. We explored a new active case-finding strategy for COPD using handheld spirometry.We recruited subjects over 40 years of age with a smoking history of more than 10 pack-years who visited a primary clinic complaining of respiratory symptoms. A total of 190 of subjects were enrolled. Medical information was obtained from historical records and physical examination by general practitioners. All subjects had their pulmonary function evaluated using handheld spirometry with a COPD-6 device. Because forced expiratory volume in 6 seconds (FEV6) has been suggested as an alternative to FVC, we measured forced expiratory volume in 1 second (FEV1)/FEV6 for diagnosis of airflow limitation. All subjects were then referred to tertiary referral hospitals to complete a "Could it be COPD?" questionnaire, handheld spiromtery, and conventional spirometry. The results of each instrument were compared to evaluate the efficacy of both handheld spirometry and the questionnaire.COPD was newly diagnosed in 45 (23.7%) patients. According to our receiver-operating characteristic (ROC) curve analysis, sensitivity and specificity were maximal when the FEV1/FEV6 ratio was less than 77%. The area under the ROC curve was 0.759. The sensitivity, specificity, positive predictive value, and negative predictive value were 72.7%, 77.1%, 50%, and 90%, respectively. The area under the ROC curve of respiratory symptoms listed on the questionnaire ranged from 0.5 to 0.65, which indicates that there is almost no difference compared with the results of handheld spirometry.The present study demonstrated the efficacy of handheld spirometry as an active case-finding tool for COPD in a primary clinical setting. This study suggested that physicians should recommend handheld spirometry for people over the age of 40, who have a smoking history of more than 10 pack

  16. Agreement Between an Automated Volume Breast Scanner and Handheld Ultrasound for Diagnostic Breast Examinations.

    Science.gov (United States)

    Barr, Richard G; DeVita, Robert; Destounis, Stamatia; Manzoni, Federica; De Silvestri, Annalisa; Tinelli, Carmine

    2017-10-01

    To compare the agreement and interobserver variability of diagnostic handheld ultrasound (US) and a single volume on an automated breast volume scanner (ABVS) and to determine whether there was a significant difference if the ABVS was used by a sonographer or mammographic technologist. Ninety patients scheduled for diagnostic US examinations were randomized to either handheld US or the ABVS first. The AVBS was randomized between a sonographer and a mammographic technologist performing the study. The studies were blinded, randomized, and read by 2 radiologists. The lesion with the highest Breast Imaging Reporting and Data System (BI-RADS) score was used in the analysis. Final diagnoses were made by core biopsy or follow-up for 2 years. Lesions included 9 malignant and 81 benign. The 90 patients had a mean age ± SD of 53.1 ± 16.3 years. The κ value for agreement between the ABVS and handheld US was 0.831 (95% confidence interval, 0.744-0.925), whereas the global agreement for a 7-point BI-RADS score was 0.488 (0.372-0.560). The agreement between the ABVS and handheld US was nearly the same when the ABVS was used by a mammographic technologist (κ = 0.858 [0.723-0.963]) or sonographer (κ = 0.803 [0.596-1.000]; P = .47). The areas under the receiver operating characteristic curves for characterization by the ABVS were 0.91 (0.84-0.96) for reader 1 and 0.91 (0.83-0.96) for reader 2; those for handheld US were 0.91 (0.84-0.96) for reader 1 and 0.83 (0.74-0.90) for reader 2, with no statistical difference. The agreement based on pathologic images was κ = 0.831 (0.718-0.944); for handheld US, κ = 0.795 (0.623-0.967); and for the AVBS, κ = 0.869 (0.725-1.000). Performing a single-view diagnostic ABVS examination has good agreement with a handheld diagnostic US workup. There is no difference if the ABVS is used by a sonographer or mammographic technologist. © 2017 by the American Institute of Ultrasound in Medicine.

  17. Printing of Titanium implant prototype

    International Nuclear Information System (INIS)

    Wiria, Florencia Edith; Shyan, John Yong Ming; Lim, Poon Nian; Wen, Francis Goh Chung; Yeo, Jin Fei; Cao, Tong

    2010-01-01

    Dental implant plays an important role as a conduit of force and stress to flow from the tooth to the related bone. In the load sharing between an implant and its related bone, the amount of stress carried by each of them directly related to their stiffness or modulus. Hence, it is a crucial issue for the implant to have matching mechanical properties, in particular modulus, between the implant and its related bone. Titanium is a metallic material that has good biocompatibility and corrosion resistance. Whilst the modulus of the bulk material is still higher than that of bone, it is the lowest among all other commonly used metallic implant materials, such as stainless steel or cobalt alloy. Hence it is potential to further reduce the modulus of pure Titanium by engineering its processing method to obtain porous structure. In this project, porous Titanium implant prototype is fabricated using 3-dimensional printing. This technique allows the flexibility of design customization, which is beneficial for implant fabrication as tailoring of implant size and shape helps to ensure the implant would fit nicely to the patient. The fabricated Titanium prototype had a modulus of 4.8-13.2 GPa, which is in the range of natural bone modulus. The compressive strength achieved was between 167 to 455 MPa. Subsequent cell culture study indicated that the porous Titanium prototype had good biocompatibility and is suitable for bone cell attachment and proliferation.

  18. Majorana Thermosyphon Prototype Experimental Results

    International Nuclear Information System (INIS)

    Fast, James E.; Reid, Douglas J.; Aguayo Navarrete, Estanislao

    2010-01-01

    The Majorana demonstrator will operate at liquid Nitrogen temperatures to ensure optimal spectrometric performance of its High Purity Germanium (HPGe) detector modules. In order to transfer the heat load of the detector module, the Majorana demonstrator requires a cooling system that will maintain a stable liquid nitrogen temperature. This cooling system is required to transport the heat from the detector chamber outside the shield. One approach is to use the two phase liquid-gas equilibrium to ensure constant temperature. This cooling technique is used in a thermosyphon. The thermosyphon can be designed so the vaporization/condensing process transfers heat through the shield while maintaining a stable operating temperature. A prototype of such system has been built at PNNL. This document presents the experimental results of the prototype and evaluates the heat transfer performance of the system. The cool down time, temperature gradient in the thermosyphon, and heat transfer analysis are studied in this document with different heat load applied to the prototype.

  19. A novel 1050nm handheld OCT imaging system for pediatric retinoblastoma patients: technology development and clinical study (Conference Presentation)

    Science.gov (United States)

    Nadiarnykh, Oleg; Moll, Annette C.; de Boer, Johannes F.

    2016-03-01

    We demonstrate a novel optical coherence tomography system specifically developed and validated for clinical imaging of retinoblastoma tumors in pediatric patients. The existing treatment options for this malignant tumor of the retina aim at reduction of tumor (re)growth risks, and vision preservation. The choice of optimal treatment strongly depends on skilled and detailed clinical assessment. Due to the limitations of the existing real-time diagnostic tools the patients at risk are periodically monitored with retinal imaging to confirm the absence of new tumor seedings. Three-dimensional visualization of tissue layer and microvasculature at improved axial and lateral resolution of interference-based OCT imaging provides sensitivity for detection of vital tumor tissue concurrent with local treatment. Our METC-approved system accommodates for the range of optical parameters of infants' eyes, and uses the 1050nm wavelength to access the deeper choroid layers of retina. The prototype is designed for patients in supine position under general anesthesia, where ergonomic handheld module is connected to fiber-based optical setup via umbilical cord. The system conforms to clinical safety requirements, including fully isolated low-voltage electric circuit. Focusing is performed with a mechanically tunable lens, where resolution is 6 µm axially, and varies with focusing at 10-18µm laterally. We will present optical design, performance limitations, and results of the ongoing clinical study, including the increased OCT diagnostic sensitivity in three dimensions in comparison with the established clinical imaging modalities. We will discuss images of early, active, and treated tumors, as well as follow-up on patients after local and systemic treatments.

  20. Gamma camera

    International Nuclear Information System (INIS)

    Conrad, B.; Heinzelmann, K.G.

    1975-01-01

    A gamma camera is described which obviates the distortion of locating signals generally caused by the varied light conductive capacities of the light conductors in that the flow of light through each light conductor may be varied by means of a shutter. A balancing of the flow of light through each of the individual light conductors, in effect, collective light conductors may be balanced on the basis of their light conductive capacities or properties, so as to preclude a distortion of the locating signals caused by the varied light conductive properties of the light conductors. Each light conductor has associated therewith two, relative to each other, independently adjustable shutters, of which one forms a closure member and the other an adjusting shutter. In this embodiment of the invention it is thus possible to block all of the light conductors leading to a photoelectric transducer, with the exception of those light conductors which are to be balanced. The balancing of the individual light conductors may then be obtained on the basis of the output signals of the photoelectric transducer. (auth)

  1. Prototype effect and the persuasiveness of generalizations

    OpenAIRE

    Dahlman, Christian; Sarwar, Farhan; Bååth, Rasmus; Wahlberg, Lena; Sikström, Sverker

    2015-01-01

    An argument that makes use of a generalization activates the prototype for the category used in the generalization. We conducted two experiments that investigated how the activation of the prototype affects the persuasiveness of the argument. The results of the experiments suggest that the features of the prototype overshadow and partly overwrite the actual facts of the case. The case is, to some extent, judged as if it had the features of the prototype instead of the features it actually ...

  2. Gamma ray generator

    Science.gov (United States)

    Firestone, Richard B; Reijonen, Jani

    2014-05-27

    An embodiment of a gamma ray generator includes a neutron generator and a moderator. The moderator is coupled to the neutron generator. The moderator includes a neutron capture material. In operation, the neutron generator produces neutrons and the neutron capture material captures at least some of the neutrons to produces gamma rays. An application of the gamma ray generator is as a source of gamma rays for calibration of gamma ray detectors.

  3. Handheld computers for self-administered sensitive data collection: A comparative study in Peru

    Directory of Open Access Journals (Sweden)

    Hughes James P

    2008-03-01

    Full Text Available Abstract Background Low-cost handheld computers (PDA potentially represent an efficient tool for collecting sensitive data in surveys. The goal of this study is to evaluate the quality of sexual behavior data collected with handheld computers in comparison with paper-based questionnaires. Methods A PDA-based program for data collection was developed using Open-Source tools. In two cross-sectional studies, we compared data concerning sexual behavior collected with paper forms to data collected with PDA-based forms in Ancon (Lima. Results The first study enrolled 200 participants (18–29 years. General agreement between data collected with paper format and handheld computers was 86%. Categorical variables agreement was between 70.5% and 98.5% (Kappa: 0.43–0.86 while numeric variables agreement was between 57.1% and 79.8% (Spearman: 0.76–0.95. Agreement and correlation were higher in those who had completed at least high school than those with less education. The second study enrolled 198 participants. Rates of responses to sensitive questions were similar between both kinds of questionnaires. However, the number of inconsistencies (p = 0.0001 and missing values (p = 0.001 were significantly higher in paper questionnaires. Conclusion This study showed the value of the use of handheld computers for collecting sensitive data, since a high level of agreement between paper and PDA responses was reached. In addition, a lower number of inconsistencies and missing values were found with the PDA-based system. This study has demonstrated that it is feasible to develop a low-cost application for handheld computers, and that PDAs are feasible alternatives for collecting field data in a developing country.

  4. Monitoring of WEEE plastics in regards to brominated flame retardants using handheld XRF

    Energy Technology Data Exchange (ETDEWEB)

    Aldrian, Alexia, E-mail: alexia.aldrian@unileoben.ac.at [Chair of Waste Processing Technology and Waste Management, Montanuniversitaet Leoben, Franz-Josef-Straße 18, 8700 Leoben (Austria); Ledersteger, Alfred, E-mail: a.ledersteger@saubermacher.at [Saubermacher Dienstleistungs AG, Hans-Roth-Straße 1, 8073 Feldkirchen bei Graz (Austria); Pomberger, Roland, E-mail: roland.pomberger@unileoben.ac.at [Chair of Waste Processing Technology and Waste Management, Montanuniversitaet Leoben, Franz-Josef-Straße 18, 8700 Leoben (Austria)

    2015-02-15

    Highlights: • Specification of an empirical factor for conversion from bromine to PBB and PBDE. • The handheld XRF device was validated for this particular application. • A very large number of over 4600 pieces of monitor housings was analysed. • The recyclable fraction mounts up to 85% for TV but only 53% of PC waste plastics. • A high percentage of pieces with bromine contents of over 50,000 ppm was obtained. - Abstract: This contribution is focused on the on-site determination of the bromine content in waste electrical and electronic equipment (WEEE), in particular waste plastics from television sets (TV) and personal computer monitors (PC) using a handheld X-ray fluorescence (XRF) device. The described approach allows the examination of samples in regards to the compliance with legal specifications for polybrominated biphenyls (PBBs) and polybrominated diphenyl ethers (PBDEs) directly after disassembling and facilitates the sorting out of plastics with high contents of brominated flame retardants (BFRs). In all, over 3000 pieces of black (TV) and 1600 pieces of grey (PC) plastic waste were analysed with handheld XRF technique for this study. Especially noticeable was the high percentage of pieces with a bromine content of over 50,000 ppm for TV (7%) and PC (39%) waste plastics. The applied method was validated by comparing the data of handheld XRF with results obtained by GC–MS. The results showed the expected and sufficiently accurate correlation between these two methods. It is shown that handheld XRF technique is an effective tool for fast monitoring of large volumes of WEEE plastics in regards to BFRs for on-site measurements.

  5. Implicit face prototype learning from geometric information.

    Science.gov (United States)

    Or, Charles C-F; Wilson, Hugh R

    2013-04-19

    There is evidence that humans implicitly learn an average or prototype of previously studied faces, as the unseen face prototype is falsely recognized as having been learned (Solso & McCarthy, 1981). Here we investigated the extent and nature of face prototype formation where observers' memory was tested after they studied synthetic faces defined purely in geometric terms in a multidimensional face space. We found a strong prototype effect: The basic results showed that the unseen prototype averaged from the studied faces was falsely identified as learned at a rate of 86.3%, whereas individual studied faces were identified correctly 66.3% of the time and the distractors were incorrectly identified as having been learned only 32.4% of the time. This prototype learning lasted at least 1 week. Face prototype learning occurred even when the studied faces were further from the unseen prototype than the median variation in the population. Prototype memory formation was evident in addition to memory formation of studied face exemplars as demonstrated in our models. Additional studies showed that the prototype effect can be generalized across viewpoints, and head shape and internal features separately contribute to prototype formation. Thus, implicit face prototype extraction in a multidimensional space is a very general aspect of geometric face learning. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. The Scintillator Tile Hadronic Calorimeter Prototype

    International Nuclear Information System (INIS)

    Rusinov, V.

    2006-01-01

    A high granularity scintillator hadronic calorimeter prototype is described. The calorimeter is based on a novel photodetector - Silicon Photo-Multiplier (SiPM). The main parameters of SiPM are discussed as well as readout cell construction and optimization. The experience with a small prototype production and testing is described. A new 8 k channel prototype is being manufactured now

  7. Rapid Prototyping: An Alternative Instructional Design Strategy.

    Science.gov (United States)

    Tripp, Steven D.; Bichelmeyer, Barbara

    1990-01-01

    Discusses the nature of instructional design and describes rapid prototyping as a feasible model for instructional system design (ISD). The use of prototyping in software engineering is described, similarities between software design and instructional design are discussed, and an example is given which uses rapid prototyping in designing a…

  8. Development of Real-Time Dual-Display Handheld and Bench-Top Hybrid-Mode SD-OCTs

    Directory of Open Access Journals (Sweden)

    Nam Hyun Cho

    2014-01-01

    Full Text Available Development of a dual-display handheld optical coherence tomography (OCT system for retina and optic-nerve-head diagnosis beyond the volunteer motion constraints is reported. The developed system is portable and easily movable, containing the compact portable OCT system that includes the handheld probe and computer. Eye posterior chambers were diagnosed using the handheld probe, and the probe could be fixed to the bench-top cradle depending on the volunteers’ physical condition. The images obtained using this handheld probe were displayed in real time on the computer monitor and on a small secondary built-in monitor; the displayed images were saved using the handheld probe’s built-in button. Large-scale signal-processing procedures such as k-domain linearization, fast Fourier transform (FFT, and log-scaling signal processing can be rapidly applied using graphics-processing-unit (GPU accelerated processing rather than central-processing-unit (CPU processing. The Labview-based system resolution is 1,024 × 512 pixels, and the frame rate is 56 frames/s, useful for real-time display. The 3D images of the posterior chambers including the retina, optic-nerve head, blood vessels, and optic nerve were composed using real-time displayed images with 500 × 500 × 500 pixel resolution. A handheld and bench-top hybrid mode with a dual-display handheld OCT was developed to overcome the drawbacks of the conventional method.

  9. Development and evaluation of a Gamma Camera tuning system

    International Nuclear Information System (INIS)

    Arista Romeu, E. J.; Diaz Garcia, A.; Osorio Deliz, J. F.

    2015-01-01

    Correct operation of conventional analogue Gamma Cameras implies a good conformation of the position signals that correspond to a specific photo-peak of the radionuclide of interest. In order to achieve this goal the energy spectrum from each photo multiplier tube (PMT) has to be set within the same energy window. For this reason a reliable tuning system is an important part of all gamma cameras processing systems. In this work is being tested and evaluated a new prototype of tuning card that was developed and setting up for this purpose. The hardware and software of the circuit allow the regulation if each PMT high voltage. By this means a proper gain control for each of them is accomplished. The Tuning Card prototype was simulated in a virtual model and its satisfactory operation was proven in a Siemens Orbiter Gamma Camera. (Author)

  10. MMSW. A large-size micromegas quadruplet prototype. Reconstruction efficiency and spatial resolution

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Tai-Hua; Duedder, Andreas; Schott, Matthias; Valderanis, Chrysostomos [Johannes Gutenberg-Universitaet, Mainz (Germany); Bianco, Michele; Danielsson, Hans; Degrange, Jordan; De Oliveira, Rui; Farina, Edoardo; Kuger, Fabian; Iengo, Paolo; Perez Gomez, Francisco; Sekhniaidze, Givi; Sidiropoulou, Ourania; Vergain, Maurice; Wotschack, Joerg [CERN, Geneva (Switzerland)

    2016-07-01

    One of the upgrades of the ATLAS detector for Run III and beyond is the replacement of the inner part of end cap muon tracking spectrometer with eight layers of resistive micromegas detectors. The performance of two prototype detectors, MMSW (MicroMegas Small Wheel), that adopt the design foreseen for this upgrade was studied. The prototype detectors were tested at the Mainz Microtron for the spatial resolution, with cosmic rays for the reconstruction efficiency and for high rate tests in the new Gamma Irradiation Facility (GIF++) at CERN. These measurements with analysis methods and results will be presented. First performance results are consistent with the ATLAS New Small Wheel requirements.

  11. Project management strategies for prototyping breakdowns

    DEFF Research Database (Denmark)

    Granlien, Maren Sander; Pries-Heje, Jan; Baskerville, Richard

    2009-01-01

    , managing the explorative and iterative aspects of prototyping projects is not a trivial task. We examine the managerial challenges in a small scale prototyping project in the Danish healthcare sector where a prototype breakdown and project escalation occurs. From this study we derive a framework...... of strategies for coping with escalation in troubled prototyping projects; the framework is based on project management triangle theory and is useful when considering how to manage prototype breakdown and escalation. All strategies were applied in the project case at different points in time. The strategies led...

  12. Results from the FDIRC prototype

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, D.A., E-mail: roberts@umd.edu [University of Maryland, College Park, MD 20742 (United States); Arnaud, N. [Laboratoire de l’Accélérateur Linéaire, Centre Scientifique d’Orsay, F-91898 Orsay Cedex (France); Dey, B. [University of California, Riverside, CA 92521 (United States); Borsato, M. [Laboratoire de l’Accélérateur Linéaire, Centre Scientifique d’Orsay, F-91898 Orsay Cedex (France); Leith, D.W.G.S.; Nishimura, K.; Ratcliff, B.N. [SLAC, Stanford University, Palo Alto, CA 94309 (United States); Varner, G. [University of Hawaii, Honolulu, HI 96822 (United States); Va’vra, J. [SLAC, Stanford University, Palo Alto, CA 94309 (United States)

    2014-12-01

    We present results from a novel Cherenkov imaging detector called the Focusing DIRC (FDIRC). This detector was designed as a prototype of the particle identification system for the SuperB experiment, and comprises 1/12 of the SuperB barrel azimuthal coverage with partial electronics implementation. The prototype was tested in the SLAC Cosmic Ray Telescope (CRT) which provides 3-D muon tracking with an angular resolution of ∼1.5 mrad, track position resolution of 5–6 mm, start time resolution of 70 ps, and a muon low-energy cutoff of ∼2 GeV provided by an iron range stack. The quartz focusing photon camera couples to a full-size BaBar DIRC bar box and is read out by 12 Hamamatsu H8500 MaPMTs providing 768 pixels. We used IRS2 waveform digitizing electronics to read out the MaPMTs. We present several results from our on-going development activities that demonstrate that the new optics design works very well, including: (a) single photon Cherenkov angle resolutions with and without chromatic corrections, (b) S/N ratio between the Cherenkov peak and background, which consists primarily of ambiguities in possible photon paths to a given pixel, (c) dTOP=TOP{sub measured}–TOP{sub expected} resolutions, and (d) performance of the detector in the presence of high-rate backgrounds. We also describe data analysis methods and point out limits of the present performance. - Highlights: • We present results from a novel Cherenkov imaging detector called the Focusing DIRC (FDIRC). • The prototype was tested in the SLAC Cosmic Ray Telescope (CRT) which provides 3-D muon tracking. • We present several results from our on-going development activities that demonstrate that new optics design works very well. • We describe data analysis methods and point out limits of the present performance.

  13. Digital Prototyping of Milk Products

    DEFF Research Database (Denmark)

    Frisvad, Jeppe Revall; Nielsen, Otto Højager Attermann; Skytte, Jacob Lercke

    2012-01-01

    reflectance measurements can be used for more extensive validation and for gathering data that can be used to extend our current model such that it can also predict how the optical properties develop during fermentation or acidification of milk to yogurt. A well-established way of measuring optical properties...... prototyping of milk products such that it can also predict how the optical properties develop during gelation of milk to yogurt. The influence of the colloidal aggregation on the optical properties is described by the static structure factor. As our method is noninvasive, we can use our setup for monitoring...

  14. Mechanical Prototyping and Manufacturing Internship

    Science.gov (United States)

    Grenfell, Peter

    2016-01-01

    The internship was located at the Johnson Space Center (JSC) Innovation Design Center (IDC), which is a facility where the JSC workforce can meet and conduct hands-on innovative design, fabrication, evaluation, and testing of ideas and concepts relevant to NASA's mission. The tasks of the internship included mechanical prototyping design and manufacturing projects in service of research and development as well as assisting the users of the IDC in completing their manufacturing projects. The first project was to manufacture hatch mechanisms for a team in the Systems Engineering and Project Advancement Program (SETMAP) hexacopter competition. These mechanisms were intended to improve the performance of the servomotors and offer an access point that would also seal to prevent cross-contamination. I also assisted other teams as they were constructing and modifying their hexacopters. The success of this competition demonstrated a proof of concept for aerial reconnaissance and sample return to be potentially used in future NASA missions. I also worked with Dr. Kumar Krishen to prototype an improved thermos and a novel, portable solar array. Computer-aided design (CAD) software was used to model the parts for both of these projects. Then, 3D printing as well as conventional techniques were used to produce the parts. These prototypes were then subjected to trials to determine the success of the designs. The solar array is intended to work in a cluster that is easy to set up and take down and doesn't require powered servomechanisms. It could be used terrestrially in areas not serviced by power grids. Both projects improve planetary exploration capabilities to future astronauts. Other projects included manufacturing custom rail brackets for EG-2, assisting engineers working on underwater instrument and tool cases for the NEEMO project, and helping to create mock-up parts for Space Center Houston. The use of the IDC enabled efficient completion of these projects at

  15. Prototype system of secure VOD

    Science.gov (United States)

    Minemura, Harumi; Yamaguchi, Tomohisa

    1997-12-01

    Secure digital contents delivery systems are to realize copyright protection and charging mechanism, and aim at secure delivery service of digital contents. Encrypted contents delivery and history (log) management are means to accomplish this purpose. Our final target is to realize a video-on-demand (VOD) system that can prevent illegal usage of video data and manage user history data to achieve a secure video delivery system on the Internet or Intranet. By now, mainly targeting client-server systems connected with enterprise LAN, we have implemented and evaluated a prototype system based on the investigation into the delivery method of encrypted video contents.

  16. CERN LHC dipole prototype success

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    In a crash programme, the first prototype superconducting dipole magnet for CERN's LHC protonproton collider was successfully powered for the first time at CERN on 14 April, eventually sailing to 9T, above the 8.65T nominal LHC field, before quenching for the third time. The next stage is to install the delicate measuring system for making comprehensive magnetic field maps in the 10 m long, 50 mm diameter twin-apertures of the magnet. These measurements will check that the required LHC field quality has been achieved at both the nominal and injection fields

  17. Prototype plutonium-storage monitor

    International Nuclear Information System (INIS)

    Bliss, M.; Craig, R.A.; Sunberg, D.S.; Warner, R.A.

    1996-01-01

    Pacific Northwest National Laboratory (PNNL) has fabricated cerium-activated lithium silicate scintillating fibers via a hot-downdraw process. These fibers typically have an operational transmission length (e -1 length) of greater than 2 meters. This permits the fabrication of devices that, hitherto, were not possible to consider. A prototype neutron monitor for scrap Pu-storage containers was fabricated and tested for 70 days, taking data with a variety of sources in a high-background environment. These data and their implication in the context of a storage-monitor situation are discussed

  18. FY97 ICCS prototype specification

    International Nuclear Information System (INIS)

    Woodruff, J.

    1997-01-01

    The ICCS software team will implement and test two iterations of their software product during FY97. This document specifies the products to be delivered in that first prototype and projects the direction that the second prototype will take. Detailed specification of the later iteration will be written when the results of the first iteration are complete. The selection of frameworks to be implemented early is made on a basis of risk analysis from the point of view of future development in the ICCS project. The prototype will address risks in integration of object- oriented components, in refining our development process, and in emulation testing for FEP devices. This document is a specification that identifies products and processes to undertake for resolving these risks. The goals of this activity are to exercise our development process at a modest scale and to probe our architecture plan for fundamental limits and failure modes. The product of the iterations will be the framework software which will be useful in future ICCS code. Thus the FY97 products are intended for internal usage by the ICCS team and for demonstration to the FEP software developers of the strategy for integrating supervisory software with FEP computers. This will be the first of several expected iterations of the software development process and the performance measurements that ICCS will demonstrate, intended to support confidence in our ability to meet project RAM goals. The design of the application software is being carried out in a separate WBS 1.5.2 activity. The design activity has as its FY97 product a series of Software Design Documents that will specify the functionality of the controls software of ICCS. During the testing of this year''s prototypes, the application functionality needed for test will be provided by sample maintenance controls. These are early precursors of controls that can be used for low level device control. Since the devices under test will be represented by

  19. Rapid prototyping of robotic platforms

    CSIR Research Space (South Africa)

    De Ronde, Willis

    2016-11-01

    Full Text Available of thickness up to 200mm can be cut to create prototype chassis/ bodies or even the final product. One of the few limitations is the cutting of certain laminated materials, as this tends to produce delaminated cutting edges or even fractures in the case... mine inspection robot (Shongololo). Shongololo’s frame is made from engineering plastics while the chassis of Dassie was made from aluminium and cut using abrasive waterjet machining. The advantage of using abrasive waterjet machining is the speed...

  20. Rapid and Accurate Assembly Method for a New Laue Lens Prototype

    DEFF Research Database (Denmark)

    Wade, Colin; Barriere, Nicolas; Hanlon, Lorraine

    2015-01-01

    The Laue lens is a technology for gamma-ray astrophysics whereby gamma-rays of particular energies can be focused by a suitable arrangement of crystals. The Laue lens assembly station at UC Berkeley was used to build a technological demonstrator addressing the key issues of crystal mounting speed......, crystal position and orientation accuracy, and crystal reflectivity. The new prototype is a lens segment containing a total of 48 5 x 5 mm2 crystals - 36 Iron and 12 Aluminium. The segment is composed of 8 partial rings, each of which is aligned to diffract an energy between 95 and 130 keV from a source...

  1. Detection of pigments of halophilic endoliths from gypsum: Raman portable instrument and European Space Agency's prototype analysis

    Science.gov (United States)

    Culka, Adam; Osterrothová, Kateřina; Hutchinson, Ian; Ingley, Richard; McHugh, Melissa; Oren, Aharon; Edwards, Howell G. M.; Jehlička, Jan

    2014-01-01

    A prototype instrument, under development at the University of Leicester, for the future European Space Agency (ESA) ExoMars mission, was used for the analysis of microbial pigments within a stratified gypsum crust from a hypersaline saltern evaporation pond at Eilat (Israel). Additionally, the same samples were analysed using a miniaturized Raman spectrometer, featuring the same 532 nm excitation. The differences in the position of the specific bands, attributed to carotenoid pigments from different coloured layers, were minor when analysed by the ESA prototype instrument; therefore, making it difficult to distinguish among the different pigments. The portable Delta Nu Advantage instrument allowed for the discrimination of microbial carotenoids from the orange/green and purple layers. The purpose of this study was to complement previous laboratory results with new data and experience with portable or handheld Raman systems, even with a dedicated prototype Raman system for the exploration of Mars. The latter is equipped with an excitation wavelength falling within the carotenoid polyene resonance region. The ESA prototype Raman instrument detected the carotenoid pigments (biomarkers) with ease, although further detailed distinctions among them were not achieved. PMID:25368354

  2. Detection of pigments of halophilic endoliths from gypsum: Raman portable instrument and European Space Agency's prototype analysis.

    Science.gov (United States)

    Culka, Adam; Osterrothová, Kateřina; Hutchinson, Ian; Ingley, Richard; McHugh, Melissa; Oren, Aharon; Edwards, Howell G M; Jehlička, Jan

    2014-12-13

    A prototype instrument, under development at the University of Leicester, for the future European Space Agency (ESA) ExoMars mission, was used for the analysis of microbial pigments within a stratified gypsum crust from a hypersaline saltern evaporation pond at Eilat (Israel). Additionally, the same samples were analysed using a miniaturized Raman spectrometer, featuring the same 532 nm excitation. The differences in the position of the specific bands, attributed to carotenoid pigments from different coloured layers, were minor when analysed by the ESA prototype instrument; therefore, making it difficult to distinguish among the different pigments. The portable Delta Nu Advantage instrument allowed for the discrimination of microbial carotenoids from the orange/green and purple layers. The purpose of this study was to complement previous laboratory results with new data and experience with portable or handheld Raman systems, even with a dedicated prototype Raman system for the exploration of Mars. The latter is equipped with an excitation wavelength falling within the carotenoid polyene resonance region. The ESA prototype Raman instrument detected the carotenoid pigments (biomarkers) with ease, although further detailed distinctions among them were not achieved. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  3. Low-friction nanojoint prototype

    Science.gov (United States)

    Vlassov, Sergei; Oras, Sven; Antsov, Mikk; Butikova, Jelena; Lõhmus, Rünno; Polyakov, Boris

    2018-05-01

    High surface energy of individual nanostructures leads to high adhesion and static friction that can completely hinder the operation of nanoscale systems with movable parts. For instance, silver or gold nanowires cannot be moved on silicon substrate without plastic deformation. In this paper, we experimentally demonstrate an operational prototype of a low-friction nanojoint. The movable part of the prototype is made either from a gold or silver nano-pin produced by laser-induced partial melting of silver and gold nanowires resulting in the formation of rounded bulbs on their ends. The nano-pin is then manipulated into the inverted pyramid (i-pyramids) specially etched in a Si wafer. Due to the small contact area, the nano-pin can be repeatedly tilted inside an i-pyramid as a rigid object without noticeable deformation. At the same time in the absence of external force the nanojoint is stable and preserves its position and tilt angle. Experiments are performed inside a scanning electron microscope and are supported by finite element method simulations.

  4. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 4 discusses the following topics: Rod Compaction/Loading System Test Results and Analysis Report; Waste Collection System Test Results and Analysis Report; Waste Container Transfer Fixture Test Results and Analysis Report; Staging and Cutting Table Test Results and Analysis Report; and Upper Cutting System Test Results and Analysis Report

  5. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 5 discusses the following topics: Lower Cutting System Test Results and Analysis Report; NFBC Loading System Test Results and Analysis Report; Robotic Bridge Transporter Test Results and Analysis Report; RM-10A Remotec Manipulator Test Results and Analysis Report; and Manipulator Transporter Test Results and Analysis Report

  6. Cosmic gamma bursts

    International Nuclear Information System (INIS)

    Ehstulin, I.V.

    1980-01-01

    A brief consideration is being given to the history of cosmic gamma burst discovery and modern knowledge of their properties. The time dependence of gamma bursts is described and their possible sources are discussed

  7. A conceptual application for computer-based procedures for handheld devices

    International Nuclear Information System (INIS)

    Sofie, Lunde-Hanssen Linda

    2014-01-01

    This paper describes the concepts and proposed design principles for an application for computer-based procedures (CBPs) for field operators in the nuclear domain (so-called handheld procedures). The concept is focused on the field operators' work with procedures and the communication and coordination between field operators and control room operators. The goal is to overcome challenges with shared situation awareness (SA) in a distributed team by providing effective and usable information design. An iterative design method and user-centred design is used for tailoring the concept to the context of field operations. The resulting concept supports the execution of procedures where close collaboration is needed between control room and field operations, e.g. where particular procedure steps are executed from remote control points and others from the control room. The resulting conceptual application for CBPs on handheld devices is developed for mitigating the SA challenges and designing for usability and ease of use

  8. Application of Handheld Laser-Induced Breakdown Spectroscopy (LIBS) to Geochemical Analysis.

    Science.gov (United States)

    Connors, Brendan; Somers, Andrew; Day, David

    2016-05-01

    While laser-induced breakdown spectroscopy (LIBS) has been in use for decades, only within the last two years has technology progressed to the point of enabling true handheld, self-contained instruments. Several instruments are now commercially available with a range of capabilities and features. In this paper, the SciAps Z-500 handheld LIBS instrument functionality and sub-systems are reviewed. Several assayed geochemical sample sets, including igneous rocks and soils, are investigated. Calibration data are presented for multiple elements of interest along with examples of elemental mapping in heterogeneous samples. Sample preparation and the data collection method from multiple locations and data analysis are discussed. © The Author(s) 2016.

  9. A conceptual application for computer-based procedures for handheld devices

    Energy Technology Data Exchange (ETDEWEB)

    Sofie, Lunde-Hanssen Linda [Industrial Psychology, Institute for Energy Technology, Halden (Norway)

    2014-08-15

    This paper describes the concepts and proposed design principles for an application for computer-based procedures (CBPs) for field operators in the nuclear domain (so-called handheld procedures). The concept is focused on the field operators' work with procedures and the communication and coordination between field operators and control room operators. The goal is to overcome challenges with shared situation awareness (SA) in a distributed team by providing effective and usable information design. An iterative design method and user-centred design is used for tailoring the concept to the context of field operations. The resulting concept supports the execution of procedures where close collaboration is needed between control room and field operations, e.g. where particular procedure steps are executed from remote control points and others from the control room. The resulting conceptual application for CBPs on handheld devices is developed for mitigating the SA challenges and designing for usability and ease of use.

  10. Hand-held transendoscopic robotic manipulators: A transurethral laser prostate surgery case study.

    Science.gov (United States)

    Hendrick, Richard J; Mitchell, Christopher R; Herrell, S Duke; Webster, Robert J

    2015-11-01

    Natural orifice endoscopic surgery can enable incisionless approaches, but a major challenge is the lack of small and dexterous instrumentation. Surgical robots have the potential to meet this need yet often disrupt the clinical workflow. Hand-held robots that combine thin manipulators and endoscopes have the potential to address this by integrating seamlessly into the clinical workflow and enhancing dexterity. As a case study illustrating the potential of this approach, we describe a hand-held robotic system that passes two concentric tube manipulators through a 5 mm port in a rigid endoscope for transurethral laser prostate surgery. This system is intended to catalyze the use of a clinically superior, yet rarely attempted, procedure for benign prostatic hyperplasia. This paper describes system design and experiments to evaluate the surgeon's functional workspace and accuracy using the robot. Phantom and cadaver experiments demonstrate successful completion of the target procedure via prostate lobe resection.

  11. A study of cladding technology on tube wall surface by a hand-held laser torch

    International Nuclear Information System (INIS)

    Terada, Takaya; Nishimura, Akihiko; Oka, Kiyoshi; Moriyama, Taku; Matsuda, Hiroyasu

    2015-01-01

    New maintenance technique was proposed using a hand-held laser torch for aging chemical plants and power plants. The hand-held laser torch was specially designed to be able to access limited tubular space in various cases. A composite-type optical fiberscope was composed of a center fiber for beam delivery and surrounded fibers for visible image delivery. Laser irradiation on a work pieces with the best accuracy of filler wire was carried out. And, we found that the optimized wire-feed speed was 2 mm/s in laser cladding. We succeeded to make a line clad on the inner wall of 23 mm tube. This technique was discussed to be applied to the maintenance for cracks or corrosions of tubes in various harsh environments. (author)

  12. Leakage and scattered radiation from hand-held dental x-ray unit

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Kyung [Dankook Univ. School of Dentistry, Seoul (Korea, Republic of)

    2007-06-15

    To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR {iota}{iota}{iota} was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of hand-held dental X-ray unit were 70 kVp, 3 mA , 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. The mean dose at the hand level when human skull DXTTR {iota}{iota}{iota} was exposed with portable X-ray unit 6.39 {mu}Gy, and the mean dose with fixed X-ray unit 3.03 {mu}Gy (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was 2.97 {mu}Gy and with fixed X-ray unit the mean dose was 0.68 {mu}Gy (p<0.01). The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography.

  13. Precise intraoperative location of gastrointestinal bleeding with a hand-held counter. Work in progress

    International Nuclear Information System (INIS)

    Williamson, M.R.; Boyd, C.M.; McGuire, E.L.

    1986-01-01

    The nuclear medicine bleeding scan is frequently insufficient to locate sites of bleeding precisely, in spite of its great sensitivity. A small, hand-held Geiger-Mueller counter, placed directly on exposed intestine in the operating room, enables precise location of the probable bleeding site. In three patients, the technique allowed a minimal amount of intestine to be resected, distinguished between large- and small-intestinal hemorrhage, and eliminated other foci as sites of bleeding.A

  14. Leakage and scattered radiation from hand-held dental x-ray unit

    International Nuclear Information System (INIS)

    Kim, Eun Kyung

    2007-01-01

    To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR ΙΙΙ was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of hand-held dental X-ray unit were 70 kVp, 3 mA , 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. The mean dose at the hand level when human skull DXTTR ΙΙΙ was exposed with portable X-ray unit 6.39 μGy, and the mean dose with fixed X-ray unit 3.03 μGy (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was 2.97 μGy and with fixed X-ray unit the mean dose was 0.68 μGy (p<0.01). The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography

  15. 3D handheld endoscope for optical coherence tomography of the human oral mucosa in vivo

    Science.gov (United States)

    Walther, Julia; Schnabel, Christian; Ebert, Nadja; Baumann, Michael; Koch, Edmund

    2017-07-01

    The early non-invasive diagnosis of epithelial tissue alterations in daily clinical routine is still challenging. Since optical coherence tomography (OCT) shows the potential to differentiate between benign and malignant tissue of primal endothelium, OCT could be beneficial for the early diagnosis of malignancies in routine health checks. In this research, a new handheld endoscopic scanning unit was designed and connected to a spectral domain OCT system of our workgroup for the in vivo imaging of the human oral mucosa.

  16. Handheld Delivery System for Modified Boron-Type Fire Extinguishment Agent

    Science.gov (United States)

    1993-11-01

    was to develop and test a handheld portable delivery system for use with the modified boron-type fire extinguishing agent for metal fires . B...BACKGROUND A need exists for an extinguishing agent and accompanying delivery system that are effective against complex geometry metal fires . A modified...agent and its delivery system have proven effective against complex geometry metal fires containing up to 200 pounds of magnesium metal. Further

  17. Beyond mere information provisioning: a handheld museum guide based on social activities and playful learning

    OpenAIRE

    SCHROYEN, Jolien; GABRIELS, Kris; TEUNKENS, Daniel; ROBERT, Karel; LUYTEN, Kris; CONINX, Karin

    2007-01-01

    During a museum visit, social interaction can improve intellectual, social, personal and cultural development. With the advances in technology, the use of personal mobile handheld devices – such as Personal Digital Assistants (PDAs) – that replace the traditional paper guidebooks is becoming a common sight at various heritage sites all over the world. This technology often leads to problems such as isolating visitors from their companions and distracting visitors away from their surroundings....

  18. Abdominoplasty and seroma: a prospective randomised study comparing scalpel and handheld electrocautery dissection.

    Science.gov (United States)

    Marsh, Dan J; Fox, Andreas; Grobbelaar, Adriaan O; Chana, Jagdeep S

    2015-02-01

    Seroma formation remains a significant problem in abdominoplasty procedures--the cause of which remains to be elucidated. It has been suggested that one of the causative factors for seroma formation is the use of handheld electrocautery as opposed to scalpel for abdominal flap dissection. Prospective trial in 102 consecutive abdominoplasty patients randomised to have abdominal flap dissection with either handheld electrocautery device on 'coagulation setting' or sharp dissection with scalpel and monopolar electrocautery forceps for haemostasis. In all other aspects the surgical technique was identical between the two groups. All drains were removed at 48 h, irrespective of drain volume. Primary outcome measure is postoperative seroma formation on clinical examination, secondary outcome measures are drain volume, weight of tissue removed, effect of liposuction and patient BMI. Both study groups were similar in demographics with no significant difference in weight of tissue excised, BMI, drain output or post operative complictions. There was no significant difference in seroma formation rates between the handheld electrocautery group (17.2%) and the sharp dissection group (20.1%). Overall, the seroma rate was 18.6%. Liposuction to the flanks at the time of abdominoplasty was found to significantly increase the incidence of seroma, compared to patients having abdominoplasty alone. Use of handheld electrocautery rather than scalpel for tissue dissection does not lead to increased seroma formation in abdominoplasty patients. Concomitant liposuction at the time of abdominoplasty increases the risk of seroma formation compared to patients having abdominoplasty alone. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  19. Gamma ray astronomy

    International Nuclear Information System (INIS)

    Broomhead, Laurent.

    1980-01-01

    The nuclear gamma astronomy is presented, in particular the Gamma Ray Observatory, an enormous eight tonnes machine fitted with gamma telescopes, scheduled for launching around 1985. It is thereby hoped to study the natural nuclear reactions which occur when stars explode [fr

  20. Jump Training in Youth Soccer Players: Effects of Haltere Type Handheld Loading.

    Science.gov (United States)

    Rosas, F; Ramirez-Campillo, R; Diaz, D; Abad-Colil, F; Martinez-Salazar, C; Caniuqueo, A; Cañas-Jamet, R; Loturco, I; Nakamura, F Y; McKenzie, C; Gonzalez-Rivera, J; Sanchez-Sanchez, J; Izquierdo, M

    2016-12-01

    The aim of this study was to compare the effects of a jump training program, with or without haltere type handheld loading, on maximal intensity exercise performance. Youth soccer players (12.1±2.2 y) were assigned to either a jump training group (JG, n=21), a jump training group plus haltere type handheld loading (LJG, n=21), or a control group following only soccer training (CG, n=21). Athletes were evaluated for maximal-intensity performance measures before and after 6 weeks of training, during an in-season training period. The CG achieved a significant change in maximal kicking velocity only (ES=0.11-0.20). Both jump training groups improved in right leg (ES=0.28-0.45) and left leg horizontal countermovement jump with arms (ES=0.32-0.47), horizontal countermovement jump with arms (ES=0.28-0.37), vertical countermovement jump with arms (ES=0.26), 20-cm drop jump reactive strength index (ES=0.20-0.37), and maximal kicking velocity (ES=0.27-0.34). Nevertheless, compared to the CG, only the LJG exhibited greater improvements in all performance tests. Therefore, haltere type handheld loading further enhances performance adaptations during jump training in youth soccer players. © Georg Thieme Verlag KG Stuttgart · New York.

  1. The reliability and validity of hand-held refractometry water content measures of hydrogel lenses.

    Science.gov (United States)

    Nichols, Jason J; Mitchell, G Lynn; Good, Gregory W

    2003-06-01

    To investigate within- and between-examiner reliability and validity of hand-held refractometry water content measures of hydrogel lenses. Nineteen lenses of various nominal water contents were examined by two examiners on two occasions separated by 1 hour. An Atago N2 hand-held refractometer was used for all water content measures. Lenses were presented in a random order to each examiner by a third party, and examiners were masked to any potential lens identifiers. Intraclass correlation coefficients (ICC), 95% limits of agreement, and Wilcoxon signed rank test were used to characterize the within- and between-examiner reliability and validity of lens water content measures. Within-examiner reliability was excellent (ICC, 0.97; 95% limits of agreement, -3.6% to +5.7%), and the inter-visit mean difference of 1.1 +/- 2.4% was not biased (p = 0.08). Between-examiner reliability was also excellent (ICC, 0.98; 95% limits of agreement, -4.1% to +3.9%). The mean difference between examiners was -0.1 +/- 2.1% (p = 0.83). The mean difference between the nominally reported water content and our water content measures was -2.1 +/- 1.7% (p refractometry and is material dependent. Therefore, investigators may need to account for bias when measuring hydrogel lens water content via hand-held refractometry.

  2. Gen-2 Hand-Held Optical Imager towards Cancer Imaging: Reflectance and Transillumination Phantom Studies

    Directory of Open Access Journals (Sweden)

    Anuradha Godavarty

    2012-02-01

    Full Text Available Hand-held near-infrared (NIR optical imagers are developed by various researchers towards non-invasive clinical breast imaging. Unlike these existing imagers that can perform only reflectance imaging, a generation-2 (Gen-2 hand-held optical imager has been recently developed to perform both reflectance and transillumination imaging. The unique forked design of the hand-held probe head(s allows for reflectance imaging (as in ultrasound and transillumination or compressed imaging (as in X-ray mammography. Phantom studies were performed to demonstrate two-dimensional (2D target detection via reflectance and transillumination imaging at various target depths (1–5 cm deep and using simultaneous multiple point illumination approach. It was observed that 0.45 cc targets were detected up to 5 cm deep during transillumination, but limited to 2.5 cm deep during reflectance imaging. Additionally, implementing appropriate data post-processing techniques along with a polynomial fitting approach, to plot 2D surface contours of the detected signal, yields distinct target detectability and localization. The ability of the gen-2 imager to perform both reflectance and transillumination imaging allows its direct comparison to ultrasound and X-ray mammography results, respectively, in future clinical breast imaging studies.

  3. Epidemiology of Handheld Cell Phone Use While Driving: A Study from a South Indian City.

    Science.gov (United States)

    Majgi, Sumanth Mallikarjuna; AiswaryaLakshmi, A S

    2018-01-01

    Using cell phones while driving contribute to distractions which can potentially cause minor or major road traffic injuries and also stress among other drivers. With this background, the study was done to ascertain the proportion of handheld cell phone use while driving among road users in Mysore city and also patterns of the use by the day of week, type of road, and type of vehicle. The study was conducted in Mysore, Karnataka, India. Four stretches of roads were observed thrice daily for 1 week. The total number of vehicles passing through the stretch and the number and characteristics of drivers using hand-held cell was noted. Pearson's Chi-square test was used to ascertain the significance of the difference in proportions. The overall proportion of cell phone users was calculated as 1.41/100 vehicles. The observed use of handheld cell phones was 1.78 times higher on nonbusy roads than busy roads ( Χ 2 = 25.79, P phone users were driving a two wheeler, the proportion being 50.5% in busy roads, and 67% in nonbusy roads. There was no difference in the proportion of cell phone use by time of the day or across different days of the week. The proportion of drivers who use cell phones is found to be relatively lower, and use of cell phones was higher on nonbusy roads.

  4. Application of Handheld Tele-ECG for Health Care Delivery in Rural India

    Directory of Open Access Journals (Sweden)

    Meenu Singh

    2014-01-01

    Full Text Available Telemonitoring is a medical practice that involves remotely monitoring patients who are not at the same location as the health care provider. The purpose of our study was to use handheld tele-electrocardiogram (ECG developed by Bhabha Atomic Research Center (BARC to identify heart conditions in the rural underserved population where the doctor-patient ratio is low and access to health care is difficult. The objective of our study was clinical validation of handheld tele-ECG as a screening tool for evaluation of cardiac diseases in the rural population. ECG was obtained in 450 individuals (mean age 31.49 ± 20.058 residing in the periphery of Chandigarh, India, from April 2011 to March 2013, using the handheld tele-ECG machine. The data were then transmitted to physicians in Postgraduate Institute of Medical Education and Research (PGIMER, Chandigarh, for their expert opinion. ECG was interpreted as normal in 70% individuals. Left ventricular hypertrophy (9.3% was the commonest abnormality followed closely by old myocardial infarction (5.3%. Patient satisfaction was reported to be ~95%. Thus, it can be safely concluded that tele-ECG is a portable, cost-effective, and convenient tool for diagnosis and monitoring of heart diseases and thus improves quality and accessibility, especially in rural areas.

  5. Prototype moving-ring reactor

    International Nuclear Information System (INIS)

    Smith, A.C. Jr.; Ashworth, C.P.; Abreu, K.E.

    1982-01-01

    We have completed a design of the Prototype Moving-Ring Reactor. The fusion fuel is confined in current-carrying rings of magnetically-field-reversed plasma (Compact Toroids). The plasma rings, formed by a coaxial plasma gun, undergo adiabatic magnetic compression to ignition temperature while they are being injected into the reactor's burner section. The cylindrical burner chamber is divided into three burn stations. Separator coils and a slight axial guide field gradient are used to shuttle the ignited toroids rapidly from one burn station to the next, pausing for 1/3 of the total burn time at each station. D-T- 3 He ice pellets refuel the rings at a rate which maintains constant radiated power

  6. LEP vacuum chamber, early prototype

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    The structure of LEP, with long bending magnets and little access to the vacuum chamber between them, required distributed pumping. This is an early prototype for the LEP vacuum chamber, made from extruded aluminium. The main opening is for the beam. The small channel to the right is for cooling water, to carry away the heat deposited by the synchroton radiation from the beam. The 4 slots in the channel to the left house the strip-shaped ion-getter pumps (see 7810255). The ion-getter pumps depended on the magnetic field of the bending magnets, too low at injection energy for the pumps to function well. Also, a different design was required outside the bending magnets. This design was therefore abandoned, in favour of a thermal getter pump (see 8301153 and 8305170).

  7. Prototype international quality assurance program

    International Nuclear Information System (INIS)

    Broadway, J.A.; Chambless, D.A.; Sapozhnikov, Yu.A.; Kalmykov, S.N.

    1998-01-01

    The international community presently lacks the ability to determine the quality and credibility of environmental measurements that is required to make sound decisions in matters related to international security, public health, and investment-related considerations. The ultimate goal of the work described in this article is to develop a credible information base including measurement capability for determination of environmental contamination and the potential for proliferation of material components of chemical or nuclear weapons. This study compared the accuracy obtained by six Russian and six U.S. laboratories for samples representative of classes of trace metals, dioxing-furans, and radioactive substances. The results obtained in this work indicate that current estimates for laboratory accuracy are likely overly optimistic. The weaknesses discovered by this prototype U.S. - Russia study also exist within the broader international community of laboratories. Further work is proposed to address the urgent need for the international community to improve performance evaluations for analytical measurements. (author)

  8. Prototype of industrial electrons accelerator

    International Nuclear Information System (INIS)

    Lopez, V.H.; Valdovinos, A.M.

    1992-01-01

    The interest and the necessity of Mexico's industry in the use of irradiation process has been increased in the last years. As examples are the irradiation of combustion gases (elimination of NO x and SO 2 ) and the polymer cross-linking between others. At present time at least twelve enterprises require immediately of them which have been contacted by electron accelerators suppliers of foreign countries. The first project step consisted in to identify the electrons accelerator type that in can be constructed in Mexico with the major number of possible equipment, instruments, components and acquisition materials local and useful for the major number of users. the characteristics of the accelerator prototype are: accelerator type transformer with multiple secondary insulated and rectifier circuits with a potential of 0.8 MV of voltage, the second step it consisted in an economic study that permitted to demonstrate the economic feasibility of its construction. (Author)

  9. Hadron therapy information sharing prototype

    CERN Document Server

    Roman, Faustin Laurentiu; Kanellopoulos, Vassiliki; Amoros, Gabriel; Davies, Jim; Dosanjh, Manjit; Jena, Raj; Kirkby, Norman; Peach, Ken; Salt, Jose

    2013-01-01

    The European PARTNER project developed a prototypical system for sharing hadron therapy data. This system allows doctors and patients to record and report treatment-related events during and after hadron therapy. It presents doctors and statisticians with an integrated view of adverse events across institutions, using open-source components for data federation, semantics, and analysis. There is a particular emphasis upon semantic consistency, achieved through intelligent, annotated form designs. The system as presented is ready for use in a clinical setting, and amenable to further customization. The essential contribution of the work reported here lies in the novel data integration and reporting methods, as well as the approach to software sustainability achieved through the use of community-supported open-source components.

  10. PEP-II prototype klystron

    International Nuclear Information System (INIS)

    Fowkes, W.R.; Caryotakis, G.; Lee, T.G.; Pearson, C.; Wright, E.L.

    1993-04-01

    A 540-kW continuous-wave (cw) klystron operating at 476 MHz was developed for use as a power source for testing PEP-II rf accelerating cavities and rf windows. It also serves as a prototype for a 1.2 MW cw klystron presently being developed as a potential rf source for asymmetric colliding ring use. The design incorporates the concepts and many of the parts used in the original 353 MHz PEP klystron developed sixteen years ago. The superior computer simulation codes available today result in improved performance with the cavity frequencies, drift lengths, and output circuit optimized for the higher frequency.The design and operating results of this tube are described with particular emphasis on the factors which affect efficiency and stability

  11. The Yucca Mountain Project Prototype Testing Program

    International Nuclear Information System (INIS)

    1989-10-01

    The Yucca Mountain Project is conducting a Prototype Testing Program to ensure that the Exploratory Shaft Facility (ESF) tests can be completed in the time available and to develop instruments, equipment, and procedures so the ESF tests can collect reliable and representative site characterization data. This report summarizes the prototype tests and their status and location and emphasizes prototype ESF and surface tests, which are required in the early stages of the ESF site characterization tests. 14 figs

  12. Test case preparation using a prototype

    OpenAIRE

    Treharne, Helen; Draper, J.; Schneider, Steve A.

    1998-01-01

    This paper reports on the preparation of test cases using a prototype within the context of a formal development. It describes an approach to building a prototype using an example. It discusses how a prototype contributes to the testing activity as part of a lifecycle based on the use of formal methods. The results of applying the approach to an embedded avionics case study are also presented.

  13. A prototype for JDEM science data processing

    International Nuclear Information System (INIS)

    Gottschalk, Erik E

    2011-01-01

    Fermilab is developing a prototype science data processing and data quality monitoring system for dark energy science. The purpose of the prototype is to demonstrate distributed data processing capabilities for astrophysics applications, and to evaluate candidate technologies for trade-off studies. We present the architecture and technical aspects of the prototype, including an open source scientific execution and application development framework, distributed data processing, and publish/subscribe message passing for quality control.

  14. Rapid prototyping using CBCT: an initial experience

    International Nuclear Information System (INIS)

    Yovchev, D.; Deliverska, E.; Indjova, J.; Ugrinov, R.

    2011-01-01

    This report presents a case of fibrous dysplasia in the left lower jaw of a 12-year-old girl, scanned with CBCT. On the basis of CBCT scan a model of affected jaw was produced using a rapid-prototyping three-dimensional printer. The case demonstrates the possibility to get a prototype by CBCT data. Prototypes can be used to support the diagnosis, planning, training (students and postgraduates) and to obtain informed consent from the patient.

  15. Prototype calorimeters for the NA3 experiment

    CERN Multimedia

    1975-01-01

    The NA3 Experiment was set-up on the North Area of the SPS by the CERN/ Ecole Polytechnique/College de France/ Orsay/Saclay Collaboration, to study high transverse momentum leptons and hadrons from hadron collisions. The calorimeters measured the energy of hadrons (prototype on the right) and leptons (prototype on the left). They used a new type of plastic scintillator (plexipop). (see CERN Courier of November 1975) energy (prototype on the right)

  16. Gamma-ray imaging system. Innovative technology summary report

    International Nuclear Information System (INIS)

    1998-11-01

    The RadScan 600 gamma-ray imaging system is designed to survey large surface areas for radiological contamination with accuracy and efficiency. The resulting survey data are clear, concise, and precise in describing how much contamination is present at exact locations. Data can be permanently stored electronically and on video tape, making storage and retrieval economical and efficient. This technology can perform accurate measurements in high radiation contamination areas while minimizing worker exposure. The RadScan 600 system is a safe and effective alternative to hand-held radiation detection devices. Performance data of the demonstrated survey area of the RadScan 600 system versus the baseline, which is the hand-held radiation detection devices (RO-2 and RO-7) for a given survey, production rate is 72% of the baseline. It should be noted that the innovative technology provides 100% coverage at a unit cost of $8.64/m 2 versus a static measurement of a unit cost of $1.61/m 2 for the baseline

  17. The performance of a prototype array of water Cherenkov detectors for the LHAASO project

    Science.gov (United States)

    An, Q.; Bai, Y. X.; Bi, X. J.; Cao, Z.; Chang, J. F.; Chen, G.; Chen, M. J.; Chen, S. M.; Chen, S. Z.; Chen, T. L.; Chen, X.; Chen, Y. T.; Cui, S. W.; Dai, B. Z.; Du, Q.; Danzengluobu; Feng, C. F.; Feng, S. H.; Gao, B.; Gao, S. Q.; Ge, M. M.; Gu, M. H.; Hao, X. J.; He, H. H.; Hou, C.; Hu, H. B.; Hu, X. B.; Huang, J.; Huang, W. P.; Jia, H. Y.; Jiang, K.; Liu, J.; Liu, J. L.; Liu, J. S.; Liu, S. B.; Liu, Y.; Liu, Y. N.; Li, Q. J.; Li, C.; Li, F.; Li, H. C.; Li, X. R.; Lu, H.; Lv, H. K.; Mao, Y. J.; Ma, L. L.; Ma, X. H.; Shao, J.; Shao, M.; Sheng, X. D.; Sun, G. X.; Sun, Z. B.; Tang, Z. B.; Wu, C. Y.; Wu, H. R.; Wu, Q.; Xiao, G.; Xu, Y.; Yang, Q. Y.; Yang, R.; Yao, Z. G.; You, X. H.; Yuan, A. F.; Zhang, B. K.; Zhang, H. M.; Zhang, S. R.; Zhang, S. S.; Zhang, X. Y.; Zhang, Y.; Zhang, L.; Zhai, L. M.; Zhao, J.; Zhao, L.; Zhao, Z. G.; Zha, M.; Zhou, B.; Zhu, F. R.; Zhu, K. J.; Zhuang, J.; Zuo, X.

    2013-10-01

    A large high-altitude air-shower observatory (LHAASO) is to be built at Shangri-La, Yunnan Province, China. This observatory is intended to conduct sub-TeV gamma astronomy, and as an important component of the LHAASO project, a water Cherenkov detector array (WCDA) is proposed. To investigate engineering issues and fully understand the water Cherenkov technique for detecting air showers, a prototype array at 1% scale of the LHAASO-WCDA has been built at Yang-Ba-Jing, Tibet, China. This paper introduces the prototype array setup and studies its performance by counting rate of each photomultiplier tube (PMT), trigger rates at different PMT multiplicities, and responses to air showers. Finally, the reconstructed shower directions and angular resolutions of the detected showers for the prototype array are given.

  18. Very high energy gamma ray astrophysics

    International Nuclear Information System (INIS)

    Lamb, R.C.; Lewis, D.A.

    1986-01-01

    The Whipple Observatory's atmospheric Cerenkov camera has detected TeV radiation from four galactic sources: the Crab Nebula, Cygnus X-3, Hercules X-1, and 4U0115+63. Recent simulations encourage the view that unwanted cosmic-ray background showers may be suppressed by a large factor. Emphasis in the coming year will be on determining optimum selection criteria for enhancing gamma-ray signals and in developing a prototype camera with finer angular resolution as a first step towards implementation of the HERCULES concept

  19. Reactor gamma spectrometry: status

    International Nuclear Information System (INIS)

    Gold, R.; Kaiser, B.J.

    1979-01-01

    Current work is described for Compton Recoil Gamma-Ray Spectrometry including developments in experimental technique as well as recent reactor spectrometry measurements. The current status of the method is described concerning gamma spectromoetry probe design and response characteristics. Emphasis is given to gamma spectrometry work in US LWR and BR programs. Gamma spectrometry in BR environments are outlined by focussing on start-up plans for the Fast Test Reactor (FTR). Gamma spectrometry results are presented for a LWR pressure vessel mockup in the Poolside Critical Assembly (PCA) at Oak Ridge National Laboratory

  20. MEMS-based handheld fourier domain Doppler optical coherence tomography for intraoperative microvascular anastomosis imaging.

    Directory of Open Access Journals (Sweden)

    Yong Huang

    Full Text Available To demonstrate the feasibility of a miniature handheld optical coherence tomography (OCT imager for real time intraoperative vascular patency evaluation in the setting of super-microsurgical vessel anastomosis.A novel handheld imager Fourier domain Doppler optical coherence tomography based on a 1.3-µm central wavelength swept source for extravascular imaging was developed. The imager was minimized through the adoption of a 2.4-mm diameter microelectromechanical systems (MEMS scanning mirror, additionally a 12.7-mm diameter lens system was designed and combined with the MEMS mirror to achieve a small form factor that optimize functionality as a handheld extravascular OCT imager. To evaluate in-vivo applicability, super-microsurgical vessel anastomosis was performed in a mouse femoral vessel cut and repair model employing conventional interrupted suture technique as well as a novel non-suture cuff technique. Vascular anastomosis patency after clinically successful repair was evaluated using the novel handheld OCT imager.With an adjustable lateral image field of view up to 1.5 mm by 1.5 mm, high-resolution simultaneous structural and flow imaging of the blood vessels were successfully acquired for BALB/C mouse after orthotopic hind limb transplantation using a non-suture cuff technique and BALB/C mouse after femoral artery anastomosis using a suture technique. We experimentally quantify the axial and lateral resolution of the OCT to be 12.6 µm in air and 17.5 µm respectively. The OCT has a sensitivity of 84 dB and sensitivity roll-off of 5.7 dB/mm over an imaging range of 5 mm. Imaging with a frame rate of 36 Hz for an image size of 1000(lateral×512(axial pixels using a 50,000 A-lines per second swept source was achieved. Quantitative vessel lumen patency, lumen narrowing and thrombosis analysis were performed based on acquired structure and Doppler images.A miniature handheld OCT imager that can be used for intraoperative evaluation of

  1. GammaWorkshops Proceedings

    International Nuclear Information System (INIS)

    Ramebaeck, H.; Straelberg, E.; Klemola, S.; Nielsen, Sven P.; Palsson, S.E.

    2012-01-01

    Due to a sparse interaction during the last years between practioners in gamma ray spectrometry in the Nordic countries, a NKS activity was started in 2009. This GammaSem was focused on seminars relevant to gamma spectrometry. A follow up seminar was held in 2010. As an outcome of these activities it was suggested that the 2011 meeting should be focused on practical issues, e.g. different corrections needed in gamma spectrometric measurements. This three day's meeting, GammaWorkshops, was held in September at Risoe-DTU. Experts on different topics relevant for gamma spectrometric measurements were invited to the GammaWorkshops. The topics included efficiency transfer, true coincidence summing corrections, self-attenuation corrections, measurement of natural radionuclides (natural decay series), combined measurement uncertainty calculations, and detection limits. These topics covered both lectures and practical sessions. The practical sessions included demonstrations of tools for e.g. corrections and calculations of the above meantioned topics. (Author)

  2. CsI/PIN Diode Detector Manufacture and Gamma-ray Response Measurement

    International Nuclear Information System (INIS)

    Ha, Jang Ho; Park, Se Hwan; Kang, Sang Mook; Kim, Yong Kyun; Lee, Wo Kyu

    2007-01-01

    In the nuclear industry changes fast to expand from conventional industry to newly emerging market industry. Such industries are environment and security field. Conventional devices to field-orientation application are too heavy not enough to be hand held. Especially emerging environment and security markets need a device which should be handheld and available long term battery operation. Photomultiplier based detection system could not satisfied these requirements. One of the promising system is the scintillator/PIN diode device. Present investigation is motivated for the purpose of developing a gamma-ray monitoring system with nuclei identification and small and light enough to be transportable by worker

  3. Status report on the TSA Systems, Ltd., MCA465 gamma-ray confirmation instrument

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Rutherford, D.A.

    1994-01-01

    The TSA Systems, Ltd., MCA465 is hand-portable, low resolution, gamma-ray instrument for confirming special nuclear materials (SNM) and related applications. The instrument evolved from earlier TSA Systems hand-held instruments, and, since its inception in 1991, it has been undergoing cycles of evaluation and then repair or redesign to correct problems. Through the efforts of Los Alamos, Rocky Flats, and TSA Systems, the MCA465 now has achieved commendable progress toward achieving quality performance as a rapid confirmation tool for SNM

  4. Enhancing experience prototyping by the help of mixed-fidelity prototypes

    OpenAIRE

    Yasar, Ansar-Ul-Haque

    2007-01-01

    In this research review I undertook the problem related to the usage of a new concept known as the Mixed- Fidelity Prototype which is a mixture of its predecessors Low- and High- Fidelity Prototypes in Experience Prototyping. Experience Prototyping is a good way to explore, communicate and interact with the designs we develop like experiencing cycling on the ice, although the mood, snow conditions, bicycle type and many other factors really matter and tend to change with time. Experience Prot...

  5. The ALICE Dimuon Trigger Overview and Electronics Prototypes

    CERN Document Server

    Arnaldi, R; Barret, V; Bastid, N; Blanchard, G; Chiavassa, E; Cortese, P; Crochet, Philippe; Dellacasa, G; De Marco, N; Drancourt, C; Dupieux, P; Espagnon, B; Fargeix, J; Ferretti, A; Gallio, M; Genoux-Lubain, A; Lamoine, L; Lefèvre, F; Luquin, Lionel; Manso, F; Métivier, V; Musso, A; Oppedisano, C; Piccotti, A; Royer, L; Roig, O; Rosnet, P; Scalas, E; Scomparin, E; Vercellin, Ermanno

    2000-01-01

    Presentation made at RPC99 and submitted to NIM ALICE is the LHC experiment (2005) dedicated to the study of heavy ion collisions. Amongst the ALICE sub-detectors, the muon spectrometer will investigate the dimuon production from heavy resonance (J/psi, Gamma) decays, which is believed to be a promising signature of the QGP (Quark Gluon Plasma) formation.For maximum efficiency of the spectrometer, a dedicated dimuon trigger is presently built. The detector partis itself based on RPCs operated in streamer mode and is the topic of another contribution to this conference. This paper gives the principle and the simulated performances of the trigger and is also focussed on the description of the electronics prototypes and future developments. The RPCs are read-out by X and Y orthogonal strips: the front-end chips are presently developed. The signals are sent to the trigger electronics which basically performs a pt cut on the tracks to reduce the background. A prototype of fast (decision time 200 ns) programmable e...

  6. Prototyping SOS meta-theory in Maude

    NARCIS (Netherlands)

    Mousavi, M.R.; Reniers, M.A.; Mosses, P.D.; Ulidowski, I.

    2006-01-01

    We present a prototype implementation of SOS meta-theory in the Maude term rewriting language. The prototype defines the basic concepts of SOS meta-theory (e.g., transition formulae, deduction rules and transition system specifications) in Maude. Besides the basic definitions, we implement methods

  7. OPAL jet chamber full-scale prototype

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, H M; Hauschild, M; Hartmann, H; Hegerath, A; Boerner, H; Burckhart, H J; Dittmar, M; Hammarstroem, R; Heuer, R D; Mazzone, L

    1986-12-01

    The concept of a jet chamber for the central detector of OPAL was tested with a full scale prototype. The design of this prototype, its mechanical and electrical structure and its support system for high voltage, gas, laser calibration, and readout are described. Operating experience was gathered since summer 1984. The chamber performance in terms of spatial resolution and particle identification capability is given.

  8. Gamification in a Prototype Household Energy Game

    NARCIS (Netherlands)

    Fijnheer, J.D.L.; van Oostendorp, H.; Veltkamp, R.C.

    2016-01-01

    Research where gamification is used to influence household energy consumption is an emerging field. This paper reviews design features of the prototype Powersaver Game. The aim of this game is to influence household energy consumption in the long-term. The evaluation of the design of the prototype,

  9. Rapid Prototyping in Instructional Design: Creating Competencies

    Science.gov (United States)

    Fulton, Carolyn D.

    2010-01-01

    Instructional designers working in rapid prototyping environments currently do not have a list of competencies that help to identify the knowledge, skills, and attitudes (KSAs) required in these workplaces. This qualitative case study used multiple cases in an attempt to identify rapid prototyping competencies required in a rapid prototyping…

  10. Application of handheld devices to field research among underserved construction worker populations: a workplace health assessment pilot study

    Directory of Open Access Journals (Sweden)

    Fleming Lora E

    2011-04-01

    Full Text Available Abstract Background Novel low-cost approaches for conducting rapid health assessments and health promotion interventions among underserved worker groups are needed. Recruitment and participation of construction workers is particularly challenging due to their often transient periods of work at any one construction site, and their limited time during work to participate in such studies. In the present methodology report, we discuss the experience, advantages and disadvantages of using touch screen handheld devices for the collection of field data from a largely underserved worker population. Methods In March 2010, a workplace-centered pilot study to examine the feasibility of using a handheld personal device for the rapid health assessment of construction workers in two South Florida Construction sites was undertaken. A 45-item survey instrument, including health-related questions on tobacco exposure, workplace safety practices, musculoskeletal disorders and health symptoms, was programmed onto Apple iPod Touch® devices. Language sensitive (English and Spanish recruitment scripts, verbal consent forms, and survey questions were all preloaded onto the handheld devices. The experience (time to survey administration and capital cost of the handheld administration method was recorded and compared to approaches available in the extant literature. Results Construction workers were very receptive to the recruitment, interview and assessment processes conducted through the handheld devices. Some workers even welcomed the opportunity to complete the questionnaire themselves using the touch screen handheld device. A list of advantages and disadvantages emerged from this experience that may be useful in the rapid health assessment of underserved populations working in a variety of environmental and occupational health settings. Conclusions Handheld devices, which are relatively inexpensive, minimize survey response error, and allow for easy storage of data

  11. Application of handheld devices to field research among underserved construction worker populations: a workplace health assessment pilot study.

    Science.gov (United States)

    Caban-Martinez, Alberto J; Clarke, Tainya C; Davila, Evelyn P; Fleming, Lora E; Lee, David J

    2011-04-01

    Novel low-cost approaches for conducting rapid health assessments and health promotion interventions among underserved worker groups are needed. Recruitment and participation of construction workers is particularly challenging due to their often transient periods of work at any one construction site, and their limited time during work to participate in such studies. In the present methodology report, we discuss the experience, advantages and disadvantages of using touch screen handheld devices for the collection of field data from a largely underserved worker population. In March 2010, a workplace-centered pilot study to examine the feasibility of using a handheld personal device for the rapid health assessment of construction workers in two South Florida Construction sites was undertaken. A 45-item survey instrument, including health-related questions on tobacco exposure, workplace safety practices, musculoskeletal disorders and health symptoms, was programmed onto Apple iPod Touch® devices. Language sensitive (English and Spanish) recruitment scripts, verbal consent forms, and survey questions were all preloaded onto the handheld devices. The experience (time to survey administration and capital cost) of the handheld administration method was recorded and compared to approaches available in the extant literature. Construction workers were very receptive to the recruitment, interview and assessment processes conducted through the handheld devices. Some workers even welcomed the opportunity to complete the questionnaire themselves using the touch screen handheld device. A list of advantages and disadvantages emerged from this experience that may be useful in the rapid health assessment of underserved populations working in a variety of environmental and occupational health settings. Handheld devices, which are relatively inexpensive, minimize survey response error, and allow for easy storage of data. These technological research modalities are useful in the

  12. 'RIG'- surgical gamma probe for early breast cancer detection

    International Nuclear Information System (INIS)

    Walinjkar, P.B.; Singh, Gursharan; Kumar, Umesh; Pendharkar, A.S.; Choudhary, P.S.

    2004-01-01

    Breast cancer is one of the most common cancers in women, which if detected in early stage can be effectively treated and cured. Early detection is carried out by collecting a sentinel lymph node (SLN) and testing it for cancer. The surgical gamma probe is a hand-held device used in the localization of SLN. It enables the localization of the active node. Isotope Applications Division, BARC has developed indigenously a RIG Surgical Gamma Probe in consultation with the doctors from Rajiv Gandhi Cancer Institute and Research Centre, New Delhi. The system consists of microcomputer-based gamma counting system that displays the number of pulses detected by the probe in counts per second and has an audible signal in direct correlation with the count density. The detector probe is based on the scintillation detector housed in a stainless steel housing with lead collimator. The physical parameters are a high sensitivity of 5000 cps/MBq at probe tip with good spatial resolution. The performance of this probe was clinically evaluated on the basis of spatial resolution and accuracy to detect the active node. (author)

  13. Gamma-ray identification of nuclear weapon materials

    International Nuclear Information System (INIS)

    Gosnell, T. B.; Hall, J. M.; Jam, C. L.; Knapp, D. A.; Koenig, Z. M.; Luke, S. J.; Pohl, B. A.; Schach Wittenau, A. von; Wolford, J. K.

    1997-01-01

    There has been an accelerating national interest in countering nuclear smuggling. This has caused a corresponding expansion of interest in the use of gamma-ray spectrometers for checkpoint monitoring, nuclear search, and within networks of nuclear and collateral sensors. All of these are fieldable instruments--ranging from large, fixed portal monitors to hand-held and remote monitoring equipment. For operational reasons, detectors with widely varying energy resolution and detection efficiency will be employed. In many instances, such instruments must be sensitive to weak signals, always capable of recognizing the gamma-ray signatures from nuclear weapons materials (NWM), often largely insensitive to spectral alteration by radiation transport through intervening materials, capable of real-time implementation, and able to discriminate against signals from commonly encountered legitimate gamma-ray sources, such as radiopharmaceuticals. Several decades of experience in classified programs have shown that all of these properties are not easily achieved and successful approaches were of limited scope--such as the detection of plutonium only. This project was originally planned as a two-year LDRD-ER. Since funding for 1997 was not sustained, this is a report of the first year's progress

  14. Dissipative Prototyping Methods: A Manifesto

    Science.gov (United States)

    Beesley, P.

    Taking a designer's unique perspective using examples of practice in experimental installation and digital protoyping, this manifesto acts as provocation for change and unlocking new potential by encouraging changes of perspective about the material realm. Diffusive form-language is proposed as a paradigm for architectural design. This method of design is applied through 3D printing and related digital fabrication methods, offering new qualities that can be implemented in design of realms including present earth and future interplanetary environments. A paradigm shift is encouraged by questioning conventional notions of geometry that minimize interfaces and by proposing the alternatives of maximized interfaces formed by effusive kinds of formal composition. A series of projects from the Canadian research studio of the Hylozoic Architecture group are described, providing examples of component design methods employing diffusive forms within combinations of tension-integrity structural systems integrated with hybrid metabolisms employing synthetic biology. Cultural implications are also discussed, drawing from architectural theory and natural philosophy. The conclusion of this paper suggests that the practice of diffusive prototyping can offer formative strategies contributing to design of future living systems.

  15. A French fuel cell prototype

    International Nuclear Information System (INIS)

    Anon.

    2001-01-01

    A French prototype of a fuel cell based on the PEM (proton exchange membrane) technology has been designed by Helion, a branch of Technicatome, this fuel cell delivers 300 kW and will be used in naval applications and terrestrial transport. The main advantages of fuel cell are: 1) no contamination, even if the fuel used is natural gas the quantities of CO 2 and CO emitted are respectively 17 and 75 times as little as the maximal quantities allowed by European regulations, 2) efficiency, the electric yield is up to 60 % and can reach 80 % if we include the recovery of heat, 3) silent, the fuel cell itself does not make noise. The present price of fuel cell is the main reason that hampers its industrial development, this price is in fact strongly dependant on the cost of its different components: catalyzers, membranes, bipolar plates and the hydrogen supply. This article gives the technical characteristics of the Helion's fuel cell. (A.C.)

  16. Wireless Augmented Reality Prototype (WARP)

    Science.gov (United States)

    Devereaux, A. S.

    1999-01-01

    Initiated in January, 1997, under NASA's Office of Life and Microgravity Sciences and Applications, the Wireless Augmented Reality Prototype (WARP) is a means to leverage recent advances in communications, displays, imaging sensors, biosensors, voice recognition and microelectronics to develop a hands-free, tetherless system capable of real-time personal display and control of computer system resources. Using WARP, an astronaut may efficiently operate and monitor any computer-controllable activity inside or outside the vehicle or station. The WARP concept is a lightweight, unobtrusive heads-up display with a wireless wearable control unit. Connectivity to the external system is achieved through a high-rate radio link from the WARP personal unit to a base station unit installed into any system PC. The radio link has been specially engineered to operate within the high- interference, high-multipath environment of a space shuttle or space station module. Through this virtual terminal, the astronaut will be able to view and manipulate imagery, text or video, using voice commands to control the terminal operations. WARP's hands-free access to computer-based instruction texts, diagrams and checklists replaces juggling manuals and clipboards, and tetherless computer system access allows free motion throughout a cabin while monitoring and operating equipment.

  17. Wireless, low-cost, FPGA-based miniature gamma ray spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Becker, E.M., E-mail: beckere@engr.orst.edu; Farsoni, A.T.

    2014-10-11

    A compact, low-cost, wireless gamma-ray spectrometer is a tool sought by a number of different organizations in the field of radiation detection. Such a device has applications in emergency response, battlefield assessment, and personal dosimetry. A prototype device fitting this description has been constructed in the Advanced Radiation Instrumentation Laboratory at Oregon State University. The prototype uses a CsI(Tl) scintillator coupled to a solid-state photomultiplier and a 40 MHz, 12-bit, FPGA-based digital pulse processor to measure gamma radiation, and is able to be accessed wirelessly by mobile phone. The prototype device consumes roughly 420 mW, weighs about 28 g (not including battery), and measures 2.54×3.81 cm{sup 2}. The prototype device is able to achieve 5.9% FWHM energy resolution at 662 keV.

  18. Virtual Video Prototyping of Pervasive Healthcare Systems

    DEFF Research Database (Denmark)

    Bardram, Jakob Eyvind; Bossen, Claus; Madsen, Kim Halskov

    2002-01-01

    Virtual studio technology enables the mixing of physical and digital 3D objects and thus expands the way of representing design ideas in terms of virtual video prototypes, which offers new possibilities for designers by combining elements of prototypes, mock-ups, scenarios, and conventional video....... In this article we report our initial experience in the domain of pervasive healthcare with producing virtual video prototypes and using them in a design workshop. Our experience has been predominantly favourable. The production of a virtual video prototype forces the designers to decide very concrete design...... issues, since one cannot avoid paying attention to the physical, real-world constraints and to details in the usage-interaction between users and technology. From the users' perspective, during our evaluation of the virtual video prototype, we experienced how it enabled users to relate...

  19. Virtual Video Prototyping for Healthcare Systems

    DEFF Research Database (Denmark)

    Bardram, Jakob Eyvind; Bossen, Claus; Lykke-Olesen, Andreas

    2002-01-01

    Virtual studio technology enables the mixing of physical and digital 3D objects and thus expands the way of representing design ideas in terms of virtual video prototypes, which offers new possibilities for designers by combining elements of prototypes, mock-ups, scenarios, and conventional video....... In this article we report our initial experience in the domain of pervasive healthcare with producing virtual video prototypes and using them in a design workshop. Our experience has been predominantly favourable. The production of a virtual video prototype forces the designers to decide very concrete design...... issues, since one cannot avoid paying attention to the physical, real-world constraints and to details in the usage-interaction between users and technology. From the users' perspective, during our evaluation of the virtual video prototype, we experienced how it enabled users to relate...

  20. High confidence in falsely recognizing prototypical faces.

    Science.gov (United States)

    Sampaio, Cristina; Reinke, Victoria; Mathews, Jeffrey; Swart, Alexandra; Wallinger, Stephen

    2018-06-01

    We applied a metacognitive approach to investigate confidence in recognition of prototypical faces. Participants were presented with sets of faces constructed digitally as deviations from prototype/base faces. Participants were then tested with a simple recognition task (Experiment 1) or a multiple-choice task (Experiment 2) for old and new items plus new prototypes, and they showed a high rate of confident false alarms to the prototypes. Confidence and accuracy relationship in this face recognition paradigm was found to be positive for standard items but negative for the prototypes; thus, it was contingent on the nature of the items used. The data have implications for lineups that employ match-to-suspect strategies.

  1. Applications of outcrop gamma-ray logging to field development and exploration

    International Nuclear Information System (INIS)

    Jordan, D.W.; Slatt, R.M.; Gillespie, R.H.; D'Agostino, A.E.; Scheihing, M.H.

    1991-01-01

    Gamma-ray logs of outcrops have been generated using two techniques. These techniques demonstrate the applicability of outcrop logging to better understand reservoir facies architecture and exploration type problems. The first logging technique employs the use of a standard logging truck and gamma-ray sonde. The truck is positioned near the top of the cliff face and the sonde is lowered to the bottom of the cliff. Gamma-ray counts are recorded as the sonde is raised at a constant rate. The second logging technique employs the use of a commercially available, hand-held, gamma-ray scintillometer. The tool measures total radiation at the outcrop. Equally-spaced measurements are made along the section and are displayed as a function of depth below a reference point. In this paper examples of gamma-ray logging experiments conducted on turbidities of the Jackfork Group (Pennsylvanian) in central and southern Arkansas are discussed, as are application of outcrop gamma-ray logging in the Long Beach Unit of Wilmington Oil Field, California, and Point Mugu (Santa Barbara Channel), California

  2. Gamma Splines and Wavelets

    Directory of Open Access Journals (Sweden)

    Hannu Olkkonen

    2013-01-01

    Full Text Available In this work we introduce a new family of splines termed as gamma splines for continuous signal approximation and multiresolution analysis. The gamma splines are born by -times convolution of the exponential by itself. We study the properties of the discrete gamma splines in signal interpolation and approximation. We prove that the gamma splines obey the two-scale equation based on the polyphase decomposition. to introduce the shift invariant gamma spline wavelet transform for tree structured subscale analysis of asymmetric signal waveforms and for systems with asymmetric impulse response. Especially we consider the applications in biomedical signal analysis (EEG, ECG, and EMG. Finally, we discuss the suitability of the gamma spline signal processing in embedded VLSI environment.

  3. Real-time image parameterization in high energy gamma-ray astronomy using transputers

    International Nuclear Information System (INIS)

    Punch, M.; Fegan, D.J.

    1991-01-01

    Recently, significant advances in Very-High-Energy gamma-ray astronomy have been made by parameterization of the Cherenkov images arising from gamma-ray initiated showers in the Earth's atmosphere. A prototype system to evaluate the use of Transputers as a parallel-processing elements for real-time analysis of data from a Cherenkov imaging camera is described in this paper. The operation of and benefits resulting from such a system are described, and the viability of an applicaiton of the prototype system is discussed

  4. Prototypical versus contemporary Mediterranean Diet.

    Science.gov (United States)

    Rizza, W; De Gara, L; Antonelli Incalzi, R; Pedone, C

    2016-10-01

    To investigate the evolution of the Mediterranean Diet (MD) in a delimited area of Southern Italy, by comparing the diet adopted 60-70 years ago (Prototypical Mediterranean Diet, PMD) with the contemporary one (Contemporary Mediterranean Diet, CMD), and to verify to what extent they fitted the recommendations of the Italian and the USDA dietary guidelines. We recruited a total of 106 participants, divided in two groups. PMD group included 52 women aged >80 years, with a good cognitive function and full independence in basic and instrumental activities of daily living. CMD group included 20 men and 34 women aged 50-60 years. Food intake was assessed by administering the EPIC food frequency questionnaire to each participant, and an additional survey to the PMD subjects only. Both PMD and CMD showed adequate intakes of macronutrients, although some deficiencies related to micronutrient requirements were evident. CMD showed a slightly greater use of animal products, processed and sugary foods, and higher intakes of simple sugars, animal proteins (49.6 vs 28.3 g/day), animal lipids (37.8 vs 20.1 g/day), saturated fats (25.0 vs 15.8 g/day) and cholesterol (305.0 vs 258.5 g/day). PMD showed many similarities to the original version of the MD in terms of macronutrients distribution and food choices. The documented evolution of the dietary habits over a 70 years timespan suggests that nowadays Mediterranean regions adhere less strictly to the original MD, although nutrients intakes are adequate to LARN and USDA recommendations. Copyright © 2016 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.

  5. A triple GEM gamma camera for medical application

    Energy Technology Data Exchange (ETDEWEB)

    Anulli, F. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); Balla, A. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); Bencivenni, G. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); Corradi, G. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); D' Ambrosio, C. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); Domenici, D. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); Felici, G. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); Gatta, M. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); Morone, M.C. [Dipartimento di Biopatologia e Diagnostica per immagini, Universita di Roma Tor Vergata (Italy); INFN - Sezione di Roma Tor Vergata (Italy); Murtas, F. [Laboratori Nazionali di Frascati INFN, Frascati (Italy)]. E-mail: fabrizio.murtas@lnf.infn.it; Schillaci, O. [Dipartimento di Biopatologia e Diagnostica per immagini, Universita di Roma Tor Vergata (Italy)

    2007-03-01

    A Gamma Camera for medical applications 10x10cm{sup 2} has been built using a triple GEM chamber prototype. The photon converters placed in front of the three GEM foils, has been realized with different technologies. The chamber, High Voltage supplied with a new active divider made in Frascati, is readout through 64 pads, 1mm{sup 2} wide, organized in a row of 8cm long, with LHCb ASDQ chip. This Gamma Camera can be used both for X-ray movie and PET-SPECT imaging; this chamber prototype is placed in a scanner system, creating images of 8x8cm{sup 2}. Several measurements have been performed using phantom and radioactive sources of Tc99m(140keV) and Na22(511keV). Results on spatial resolution and image reconstruction are presented.

  6. Combining heterogenous features for 3D hand-held object recognition

    Science.gov (United States)

    Lv, Xiong; Wang, Shuang; Li, Xiangyang; Jiang, Shuqiang

    2014-10-01

    Object recognition has wide applications in the area of human-machine interaction and multimedia retrieval. However, due to the problem of visual polysemous and concept polymorphism, it is still a great challenge to obtain reliable recognition result for the 2D images. Recently, with the emergence and easy availability of RGB-D equipment such as Kinect, this challenge could be relieved because the depth channel could bring more information. A very special and important case of object recognition is hand-held object recognition, as hand is a straight and natural way for both human-human interaction and human-machine interaction. In this paper, we study the problem of 3D object recognition by combining heterogenous features with different modalities and extraction techniques. For hand-craft feature, although it reserves the low-level information such as shape and color, it has shown weakness in representing hiconvolutionalgh-level semantic information compared with the automatic learned feature, especially deep feature. Deep feature has shown its great advantages in large scale dataset recognition but is not always robust to rotation or scale variance compared with hand-craft feature. In this paper, we propose a method to combine hand-craft point cloud features and deep learned features in RGB and depth channle. First, hand-held object segmentation is implemented by using depth cues and human skeleton information. Second, we combine the extracted hetegerogenous 3D features in different stages using linear concatenation and multiple kernel learning (MKL). Then a training model is used to recognize 3D handheld objects. Experimental results validate the effectiveness and gerneralization ability of the proposed method.

  7. A data-driven design evaluation tool for handheld device soft keyboards.

    Directory of Open Access Journals (Sweden)

    Matthieu B Trudeau

    Full Text Available Thumb interaction is a primary technique used to operate small handheld devices such as smartphones. Despite the different techniques involved in operating a handheld device compared to a personal computer, the keyboard layouts for both devices are similar. A handheld device keyboard that considers the physical capabilities of the thumb may improve user experience. We developed and applied a design evaluation tool for different geometries of the QWERTY keyboard using a performance evaluation model. The model utilizes previously collected data on thumb motor performance and posture for different tap locations and thumb movement directions. We calculated a performance index (PITOT, 0 is worst and 2 is best for 663 designs consisting in different combinations of three variables: the keyboard's radius of curvature (R (mm, orientation (O (°, and vertical location on the screen (L. The current standard keyboard performed poorly (PITOT = 0.28 compared to other designs considered. Keyboard location (L contributed to the greatest variability in performance out of the three design variables, suggesting that designers should modify this variable first. Performance was greatest for designs in the middle keyboard location. In addition, having a slightly upward curve (R = -20 mm and orientated perpendicular to the thumb's long axis (O = -20° improved performance to PITOT = 1.97. Poorest performances were associated with placement of the keyboard's spacebar in the bottom right corner of the screen (e.g., the worst was for R = 20 mm, O = 40°, L =  Bottom (PITOT = 0.09. While this evaluation tool can be used in the design process as an ergonomic reference to promote user motor performance, other design variables such as visual access and usability still remain unexplored.

  8. Comparative Geometrical Accuracy Investigations of Hand-Held 3d Scanning Systems - AN Update

    Science.gov (United States)

    Kersten, T. P.; Lindstaedt, M.; Starosta, D.

    2018-05-01

    Hand-held 3D scanning systems are increasingly available on the market from several system manufacturers. These systems are deployed for 3D recording of objects with different size in diverse applications, such as industrial reverse engineering, and documentation of museum exhibits etc. Typical measurement distances range from 0.5 m to 4.5 m. Although they are often easy-to-use, the geometric performance of these systems, especially the precision and accuracy, are not well known to many users. First geometrical investigations of a variety of diverse hand-held 3D scanning systems were already carried out by the Photogrammetry & Laser Scanning Lab of the HafenCity University Hamburg (HCU Hamburg) in cooperation with two other universities in 2016. To obtain more information about the accuracy behaviour of the latest generation of hand-held 3D scanning systems, HCU Hamburg conducted further comparative geometrical investigations using structured light systems with speckle pattern (Artec Spider, Mantis Vision PocketScan 3D, Mantis Vision F5-SR, Mantis Vision F5-B, and Mantis Vision F6), and photogrammetric systems (Creaform HandySCAN 700 and Shining FreeScan X7). In the framework of these comparative investigations geometrically stable reference bodies were used. The appropriate reference data was acquired by measurements with two structured light projection systems (AICON smartSCAN and GOM ATOS I 2M). The comprehensive test results of the different test scenarios are presented and critically discussed in this contribution.

  9. Handheld ultrahigh speed swept source optical coherence tomography instrument using a MEMS scanning mirror.

    Science.gov (United States)

    Lu, Chen D; Kraus, Martin F; Potsaid, Benjamin; Liu, Jonathan J; Choi, Woojhon; Jayaraman, Vijaysekhar; Cable, Alex E; Hornegger, Joachim; Duker, Jay S; Fujimoto, James G

    2013-12-20

    We developed an ultrahigh speed, handheld swept source optical coherence tomography (SS-OCT) ophthalmic instrument using a 2D MEMS mirror. A vertical cavity surface-emitting laser (VCSEL) operating at 1060 nm center wavelength yielded a 350 kHz axial scan rate and 10 µm axial resolution in tissue. The long coherence length of the VCSEL enabled a 3.08 mm imaging range with minimal sensitivity roll-off in tissue. Two different designs with identical optical components were tested to evaluate handheld OCT ergonomics. An iris camera aided in alignment of the OCT beam through the pupil and a manual fixation light selected the imaging region on the retina. Volumetric and high definition scans were obtained from 5 undilated normal subjects. Volumetric OCT data was acquired by scanning the 2.4 mm diameter 2D MEMS mirror sinusoidally in the fast direction and linearly in the orthogonal slow direction. A second volumetric sinusoidal scan was obtained in the orthogonal direction and the two volumes were processed with a software algorithm to generate a merged motion-corrected volume. Motion-corrected standard 6 x 6 mm(2) and wide field 10 x 10 mm(2) volumetric OCT data were generated using two volumetric scans, each obtained in 1.4 seconds. High definition 10 mm and 6 mm B-scans were obtained by averaging and registering 25 B-scans obtained over the same position in 0.57 seconds. One of the advantages of volumetric OCT data is the generation of en face OCT images with arbitrary cross sectional B-scans registered to fundus features. This technology should enable screening applications to identify early retinal disease, before irreversible vision impairment or loss occurs. Handheld OCT technology also promises to enable applications in a wide range of settings outside of the traditional ophthalmology or optometry clinics including pediatrics, intraoperative, primary care, developing countries, and military medicine.

  10. Gamma ray astronomy

    International Nuclear Information System (INIS)

    Fichtel, C.E.

    1975-01-01

    The first certain detection of celestial high energy gamma rays came from a satellite experiment flown on the third Orbiting Solar Observatory (OSO-111). A Gamma ray spark chamber telescope with substantively greater sensitivity and angular resolution (a few degrees) flown on the second Small Astronomy Satellite (SAS-II) has now provided a better picture of the gamma ray sky, and particularly the galactic plane and pulsars. This paper will summarize the present picture of gamma ray astronomy as it has developed at this conference from measurements made with experiments carried out on balloons, those remaining on the ground, and ones flown on satellites. (orig.) [de

  11. Prototype-Incorporated Emotional Neural Network.

    Science.gov (United States)

    Oyedotun, Oyebade K; Khashman, Adnan

    2017-08-15

    Artificial neural networks (ANNs) aim to simulate the biological neural activities. Interestingly, many ''engineering'' prospects in ANN have relied on motivations from cognition and psychology studies. So far, two important learning theories that have been subject of active research are the prototype and adaptive learning theories. The learning rules employed for ANNs can be related to adaptive learning theory, where several examples of the different classes in a task are supplied to the network for adjusting internal parameters. Conversely, the prototype-learning theory uses prototypes (representative examples); usually, one prototype per class of the different classes contained in the task. These prototypes are supplied for systematic matching with new examples so that class association can be achieved. In this paper, we propose and implement a novel neural network algorithm based on modifying the emotional neural network (EmNN) model to unify the prototype- and adaptive-learning theories. We refer to our new model as ``prototype-incorporated EmNN''. Furthermore, we apply the proposed model to two real-life challenging tasks, namely, static hand-gesture recognition and face recognition, and compare the result to those obtained using the popular back-propagation neural network (BPNN), emotional BPNN (EmNN), deep networks, an exemplar classification model, and k-nearest neighbor.

  12. Rapid prototyping and stereolithography in dentistry

    Science.gov (United States)

    Nayar, Sanjna; Bhuminathan, S.; Bhat, Wasim Manzoor

    2015-01-01

    The word rapid prototyping (RP) was first used in mechanical engineering field in the early 1980s to describe the act of producing a prototype, a unique product, the first product, or a reference model. In the past, prototypes were handmade by sculpting or casting, and their fabrication demanded a long time. Any and every prototype should undergo evaluation, correction of defects, and approval before the beginning of its mass or large scale production. Prototypes may also be used for specific or restricted purposes, in which case they are usually called a preseries model. With the development of information technology, three-dimensional models can be devised and built based on virtual prototypes. Computers can now be used to create accurately detailed projects that can be assessed from different perspectives in a process known as computer aided design (CAD). To materialize virtual objects using CAD, a computer aided manufacture (CAM) process has been developed. To transform a virtual file into a real object, CAM operates using a machine connected to a computer, similar to a printer or peripheral device. In 1987, Brix and Lambrecht used, for the first time, a prototype in health care. It was a three-dimensional model manufactured using a computer numerical control device, a type of machine that was the predecessor of RP. In 1991, human anatomy models produced with a technology called stereolithography were first used in a maxillofacial surgery clinic in Viena. PMID:26015715

  13. Rapid prototyping and stereolithography in dentistry.

    Science.gov (United States)

    Nayar, Sanjna; Bhuminathan, S; Bhat, Wasim Manzoor

    2015-04-01

    The word rapid prototyping (RP) was first used in mechanical engineering field in the early 1980s to describe the act of producing a prototype, a unique product, the first product, or a reference model. In the past, prototypes were handmade by sculpting or casting, and their fabrication demanded a long time. Any and every prototype should undergo evaluation, correction of defects, and approval before the beginning of its mass or large scale production. Prototypes may also be used for specific or restricted purposes, in which case they are usually called a preseries model. With the development of information technology, three-dimensional models can be devised and built based on virtual prototypes. Computers can now be used to create accurately detailed projects that can be assessed from different perspectives in a process known as computer aided design (CAD). To materialize virtual objects using CAD, a computer aided manufacture (CAM) process has been developed. To transform a virtual file into a real object, CAM operates using a machine connected to a computer, similar to a printer or peripheral device. In 1987, Brix and Lambrecht used, for the first time, a prototype in health care. It was a three-dimensional model manufactured using a computer numerical control device, a type of machine that was the predecessor of RP. In 1991, human anatomy models produced with a technology called stereolithography were first used in a maxillofacial surgery clinic in Viena.

  14. Review on CNC-Rapid Prototyping

    International Nuclear Information System (INIS)

    M Nafis O Z; Nafrizuan M Y; Munira M A; Kartina J

    2012-01-01

    This article reviewed developments of Computerized Numerical Control (CNC) technology in rapid prototyping process. Rapid prototyping (RP) can be classified into three major groups; subtractive, additive and virtual. CNC rapid prototyping is grouped under the subtractive category which involves material removal from the workpiece that is larger than the final part. Richard Wysk established the use of CNC machines for rapid prototyping using sets of 2½-D tool paths from various orientations about a rotary axis to machine parts without refixturing. Since then, there are few developments on this process mainly aimed to optimized the operation and increase the process capabilities to stand equal with common additive type of RP. These developments include the integration between machining and deposition process (hybrid RP), adoption of RP to the conventional machine and optimization of the CNC rapid prototyping process based on controlled parameters. The article ended by concluding that the CNC rapid prototyping research area has a vast space for improvement as in the conventional machining processes. Further developments and findings will enhance the usage of this method and minimize the limitation of current approach in building a prototype.

  15. A hand-held sensor for analyses of local distributions of magnetic fields and losses

    CERN Document Server

    Krismanic, G; Baumgartinger, N

    2000-01-01

    The paper describes a novel sensor for non-destructive analyses of local field and loss distributions in laminated soft magnetic cores, such as transformer cores. It was designed for rapid information on comparative local degrees of inhomogeneity, e.g., for the estimation of local building factors. Similar to a magnifying glass with handle, the compact hand-held sensor contains extremely sharp needle electrodes for the detection of the induction vector B as well as double-field coils for the vector H. Losses P are derived from the Poynting law. Applied to inner -- or also outer -- core regions, the sensor yields instantaneous computer displays of local H, B, and P.

  16. Balancing fast-rotating parts of hand-held machine drive

    Science.gov (United States)

    Korotkov, V. S.; Sicora, E. A.; Nadeina, L. V.; Yongzheng, Wang

    2018-03-01

    The article considers the issues related to the balancing of fast rotating parts of the hand-held machine drive including a wave transmission with intermediate rolling elements, which is constructed on the basis of the single-phase collector motor with a useful power of 1 kW and a nominal rotation frequency of 15000 rpm. The forms of balancers and their location are chosen. The method of balancing is described. The scheme for determining of residual unbalance in two correction planes is presented. Measurement results are given in tables.

  17. Performance of handheld electrocardiogram devices to detect atrial fibrillation in a cardiology and geriatric ward setting.

    Science.gov (United States)

    Desteghe, Lien; Raymaekers, Zina; Lutin, Mark; Vijgen, Johan; Dilling-Boer, Dagmara; Koopman, Pieter; Schurmans, Joris; Vanduynhoven, Philippe; Dendale, Paul; Heidbuchel, Hein

    2017-01-01

    To determine the usability, accuracy, and cost-effectiveness of two handheld single-lead electrocardiogram (ECG) devices for atrial fibrillation (AF) screening in a hospital population with an increased risk for AF. Hospitalized patients (n = 445) at cardiological or geriatric wards were screened for AF by two handheld ECG devices (MyDiagnostick and AliveCor). The performance of the automated algorithm of each device was evaluated against a full 12-lead or 6-lead ECG recording. All ECGs and monitor tracings were also independently reviewed in a blinded fashion by two electrophysiologists. Time investments by nurses and physicians were tracked and used to estimate cost-effectiveness of different screening strategies. Handheld recordings were not possible in 7 and 21.4% of cardiology and geriatric patients, respectively, because they were not able to hold the devices properly. Even after the exclusion of patients with an implanted device, sensitivity and specificity of the automated algorithms were suboptimal (Cardiology: 81.8 and 94.2%, respectively, for MyDiagnostick; 54.5 and 97.5%, respectively, for AliveCor; Geriatrics: 89.5 and 95.7%, respectively, for MyDiagnostick; 78.9 and 97.9%, respectively, for AliveCor). A scenario based on automated AliveCor evaluation in patients without AF history and without an implanted device proved to be the most cost-effective method, with a provider cost to identify one new AF patient of €193 and €82 at cardiology and geriatrics, respectively. The cost to detect one preventable stroke per year would be €7535 and €1916, respectively (based on average CHA 2 DS 2 -VASc of 3.9 ± 2.0 and 5.0 ± 1.5, respectively). Manual interpretation increases sensitivity, but decreases specificity, doubling the cost per detected patient, but remains cheaper than sole 12-lead ECG screening. Using AliveCor or MyDiagnostick handheld recorders requires a structured screening strategy to be effective and cost-effective in a hospital setting

  18. Technological characteristics of digital video broadcasting: Handheld standard DVB-H

    Directory of Open Access Journals (Sweden)

    Andreja B. Samčović

    2011-07-01

    Full Text Available This paper gives an overview of the Digital Video Broadcasting - Handheld standard DVB-H, as a part of the DVB Project. This standard is based on the previous standard DVB-T, which was developed for the terrestrial digital television. The ways of DVB-H signal transmission are also described. Development of advanced technology enabled the digital video broadcasting over wireless portable terminals. This paper discusses the key technological features of the DVB-H standard, such as: time slicing, forward error correction, 4K mode and in-depth interleavers.

  19. Evaluation of a prototype infrasound system

    International Nuclear Information System (INIS)

    Whitaker, R.; Sandoval, T.; Breding, D.; Kromer, D.

    1997-01-01

    Under Department of Energy sponsorship, Sandia National Laboratories and Los Alamos National Laboratory cooperated to develop a prototype infrasonic array, with associated documentation, that could be used as part of the International Monitoring System. The United States Government or foreign countries could procure commercially available systems based on this prototype to fulfill their Comprehensive Test Ban Treaty (CTBT) obligations. The prototype is a four-element array in a triangular layout as recommended in CD/NTB/WP.224 with an element at each corner and one in the center. The prototype test configuration utilize an array spacing of 1 km. The prototype infrasound system has the following objectives: (1) Provide a prototype that reliably acquires and transmits near real-time infrasonic data to facilitate the rapid location and identification of atmospheric events. (2) Provide documentation that could be used by the United States and foreign countries to procure infrasound systems commercially to fulfill their CTBT responsibilities. Infrasonic monitoring is an effective, low cost technology for detecting atmospheric explosions. The low frequency components of explosion signals propagate to long ranges (few thousand kilometers) where they can be detected with an array of sensors. Los Alamos National Laboratory's expertise in infrasound systems and phenomenology when combined with Sandia's expertise in providing verification quality system for treaty monitoring make an excellent team to provide the prototype infrasound sensor system. By September 1997, the prototype infrasound system will have been procured, integrated, evaluated and documented. Final documentation will include a system requirements document, an evaluation report and a hardware design document. The hardware design document will describe the various hardware components used in the infrasound prototype and their interrelationships

  20. Eight years' operation of the SGHWR prototype

    International Nuclear Information System (INIS)

    Phillips, J.L.

    1976-01-01

    Experience gained of the SGHWR system during the first eight years of operation of the UKAEA's 100 MW(e) prototype at AEE Winfrith is discussed. Modifications and additions have been made to the plant to overcome problems which only operation of a prototype unit can reveal. No problems have arisen which could not be overcome by the application of normal engineering resources, and there is no reason why the commercial successor to the prototype should be other than a fully viable proposition. (author)

  1. Field Data Logger Prototype for Power Converters

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay; Ghimire, Pramod; Thøgersen, Paul Bach

    2014-01-01

    and subsequent analysis of the data. This paper presents the development of a low cost prototype field data logger prototype using Raspberry PI and industrial sensors. The functionalities of the data logger prototype are described. An online rainflow count algorithm has been implemented as well.......Mission profile data is very important for the cost effective and reliable design of power converters. The converter design can be improved on the basis of actual field data. Actual mission profile data can be collected for the power converters using field data loggers over a long period of time...

  2. NIF/LMJ prototype amplifier mechanical design

    International Nuclear Information System (INIS)

    Horvath, J.

    1996-10-01

    Amplifier prototypes for the National Ignition Facility and the Laser Megajoule will be tested at Lawrence Livermore National Laboratory. The prototype amplifier, which is an ensemble of modules from LLNL and Centre d'Etudes de Limeil-Valenton, is cassette-based with bottom access for maintenance. A sealed maintenance transfer vehicle which moves optical cassettes between the amplifier and the assembly cleanroom, and a vacuum gripper which holds laser slabs during cassette assembly will also be tested. The prototype amplifier will be used to verify amplifier optical performance, thermal recovery time, and cleanliness of mechanical operations

  3. Rapid prototyping using robot welding : process description

    OpenAIRE

    Ribeiro, António Fernando; Norrish, John

    1997-01-01

    Rapid Prototyping is a relatively recent technique to produce component prototypes for industry in a much shorter period of time, since the time to market a product is essential to its success. A new Rapid Prototyping process which uses metal as the raw material had been under development at Cranfield University in the last few years. The process uses a Gas Metal Arc fusion welding robot which deposits successive layers of metal in such way that it forms a 3D solid component. Firstly, a CAD s...

  4. Initial performance of the PIGMI prototype

    International Nuclear Information System (INIS)

    Stovall, J.E.

    1979-01-01

    The PIGMI (Pion Generator for Medical Irradiations) program at LASL is an accelerator development program aimed at completing the design of an accelerator suitable for use as a pion generator in a hospital-based radiotherapy program. The major thrust of the program has been the design of a 7 MeV prototype accelerator which emphasizes compactness, economy of construction, and operation and reliability. To achieve these goals the design of the prototype has exploited a number of innovations in proton linac technology. An overview of the program discussing the major innovative features of the prototype is presented. The initial operating experience is discussed and initial performance measurements are presented

  5. [Rapid prototyping: a very promising method].

    Science.gov (United States)

    Haverman, T M; Karagozoglu, K H; Prins, H-J; Schulten, E A J M; Forouzanfar, T

    2013-03-01

    Rapid prototyping is a method which makes it possible to produce a three-dimensional model based on two-dimensional imaging. Various rapid prototyping methods are available for modelling, such as stereolithography, selective laser sintering, direct laser metal sintering, two-photon polymerization, laminated object manufacturing, three-dimensional printing, three-dimensional plotting, polyjet inkjet technology,fused deposition modelling, vacuum casting and milling. The various methods currently being used in the biomedical sector differ in production, materials and properties of the three-dimensional model which is produced. Rapid prototyping is mainly usedforpreoperative planning, simulation, education, and research into and development of bioengineering possibilities.

  6. Evaluation of the Next Generation Gamma Imager

    International Nuclear Information System (INIS)

    Amgarou, Khalil; Timi, Tebug; Blanc de Lanaute, Nicolas; Patoz, Audrey; Talent, Philippe; Menaa, Nabil; Carrel, Frederick; Schoepff, Vincent; Lemaire, Hermine; Gmar, Mehdi; Abou Khalil, Roger; Dogny, Stephane; Varet, Thierry

    2013-06-01

    Towards the end of their life-cycle, nuclear facilities are generally associated with high levels of radiation exposure. The implementation of the ALARA principle requires limiting the radiation exposure of the operating people during the different tasks of maintenance, decontamination and decommissioning. Canberra's latest involvement in the provision of nuclear measurement solutions has led, in the framework of a partnership agreement with CEA LIST, to the development of a new generation gamma imager. The latter, which is designed for an accurate localization of radioactive hotspots, consists of a pixilated chip hybridized to a 1 mm thick CdTe substrate to record photon pulses and a coded mask aperture allowing for background noise subtraction by means of a technique called mask/anti-mask procedure. This greatly contributes to the reduced size and weight of the gamma imager as gamma shielding around the detector is less required. The spatial radioactivity map is automatically superimposed onto a pre-recorded photographic (visible) image of the scene of interest. In an effort to evaluate the performances of the new gamma imager, several experimental tests have been performed on a industrial prototype to investigate its detection response, including gamma imaging sensitivity and angular resolutions, over a wide energy range (at least from 59 keV to 1330 keV). The impact of the background noise was also evaluated together with some future features like energy discrimination and parallax correction. This paper presents and discusses the main results obtained in the above experimental study. A comparison with Monte Carlo simulations using the MCNP code is provided as well. (authors)

  7. VO for Education: Archive Prototype

    Science.gov (United States)

    Ramella, M.; Iafrate, G.; De Marco, M.; Molinaro, M.; Knapic, C.; Smareglia, R.; Cepparo, F.

    2014-05-01

    The number of remote control telescopes dedicated to education is increasing in many countries, leading to correspondingly larger and larger amount of stored educational data that are usually available only to local observers. Here we present the project for a new infrastructure that will allow teachers using educational telescopes to archive their data and easily publish them within the Virtual Observatory (VO) avoiding the complexity of professional tools. Students and teachers anywhere will be able to access these data with obvious benefits for the realization of grander scale collaborative projects. Educational VO data will also be an important resource for teachers not having direct access to any educational telescopes. We will use the educational telescope at our observatory in Trieste as a prototype for the future VO educational data archive resource. The publishing infrastructure will include: user authentication, content and curation validation, data validation and ingestion, VO compliant resource generation. All of these parts will be performed by means of server side applications accessible through a web graphical user interface (web GUI). Apart from user registration, that will be validated by a natural person responsible for the archive (after having verified the reliability of the user and inspected one or more test files), all the subsequent steps will be automated. This means that at the very first data submission through the webGUI, a complete resource including archive and published VO service will be generated, ready to be registered to the VO. The efforts required to the registered user will consist only in describing herself/himself at registration step and submitting the data she/he selects for publishing after each observation sessions. The infrastructure will be file format independent and the underlying data model will use a minimal set of standard VO keywords, some of which will be specific for outreach and education, possibly including VO

  8. Characterization of Prototype LSST CCDs

    Energy Technology Data Exchange (ETDEWEB)

    OCONNOR,P.; FRANK, J.; GEARY, J.C.; GILMORE, D.K.; KOTOV, I.; RADEKA, V.; TAKACS, P.; TYSON, J.A.

    2008-06-23

    The ambitious science goals of the Large Synoptic Survey Telescope (LSST) will be achieved in part by a wide-field imager that will achieve a new level of performance in terms of area, speed, and sensitivity. The instrument performance is dominated by the focal plane sensors, which are now in development. These new-generation sensors will make use of advanced semiconductor technology and will be complemented by a highly integrated electronics package located inside the cryostat. A test laboratory has been set up at Brookhaven National Laboratory (BNL) to characterize prototype sensors and to develop test and assembly techniques for eventual integration of production sensors and electronics into modules that will form the final focal plane. As described in [1], the key requirements for LSST sensors are wideband quantum efficiency (QE) extending beyond lpm in the red, control of point spread function (PSF), and fast readout using multiple amplifiers per chip operated in parallel. In addition, LSST's fast optical system (f71.25) places severe constraints on focal plane flatness. At the chip level this involves packaging techniques to minimize warpage of the silicon die, and at the mosaic level careful assembly and metrology to achieve a high coplanarity of the sensor tiles. In view of the long lead time to develop the needed sensor technology, LSST undertook a study program with several vendors to fabricate and test devices which address the most critical performance features [2]. The remainder of this paper presents key results of this study program. Section 2 summarizes the sensor requirements and the results of design optimization studies, and Section 3 presents the sensor development plan. In Section 4 we describe the test bench at BNL. Section 5 reports measurement results obtained to date oh devices fabricated by several vendors. Section 6 presents a summary of the paper and an outlook for the future work. We present characterization methods and results on

  9. User prototypes as partly unconscious communication

    DEFF Research Database (Denmark)

    Glasemann, Marie; Kanstrup, Anne Marie

    2010-01-01

    In this paper, we introduce user prototypes as a technique that supports users’ articulation of emotions relevant for design: dreams, fears, motivations – their feelings and aspirations. Following Bateson’s writings about communication through art, we consider user prototypes as “partly unconscious...... communication” and propose to analyze them by focusing on the emotional articulations integrated in the users’ design language. We illustrate this with an example from a design research project on designing learning technology for young diabetics. The example shows how young people with diabetes can express...... emotional themes related to youth identity, the burden of being young with a chronic illness, and the need to be connected and feel safe through design of prototypes. The new conceptual space that arises from user prototypes shows potential for addressing emotions when designing for health and for further...

  10. Homogeneity of Prototypical Attributes in Soccer Teams

    Directory of Open Access Journals (Sweden)

    Christian Zepp

    2015-09-01

    Full Text Available Research indicates that the homogeneous perception of prototypical attributes influences several intragroup processes. The aim of the present study was to describe the homogeneous perception of the prototype and to identify specific prototypical subcategories, which are perceived as homogeneous within sport teams. The sample consists of N = 20 soccer teams with a total of N = 278 athletes (age M = 23.5 years, SD = 5.0 years. The results reveal that subcategories describing the cohesiveness of the team and motivational attributes are mentioned homogeneously within sport teams. In addition, gender, identification, team size, and the championship ranking significantly correlate with the homogeneous perception of prototypical attributes. The results are discussed on the basis of theoretical and practical implications.

  11. Norcal Prototype LNG Truck Fleet: Final Results

    Energy Technology Data Exchange (ETDEWEB)

    2004-07-01

    U.S. DOE and National Renewable Energy Laboratory evaluated Norcal Waste Systems liquefied natural gas (LNG) waste transfer trucks. Trucks had prototype Cummins Westport ISXG engines. Report gives final evaluation results.

  12. Gesture recognition for an exergame prototype

    NARCIS (Netherlands)

    Gacem, Brahim; Vergouw, Robert; Verbiest, Harm; Cicek, Emrullah; Kröse, Ben; van Oosterhout, Tim; Bakkes, S.C.J.

    2011-01-01

    We will demonstrate a prototype exergame aimed at the serious domain of elderly fitness. The exergame incorporates straightforward means to gesture recognition, and utilises a Kinect camera to obtain 2.5D sensory data of the human user.

  13. System design document for the INFLO prototype.

    Science.gov (United States)

    2014-03-01

    This report documents the high level System Design Document (SDD) for the prototype development and : demonstration of the Intelligent Network Flow Optimization (INFLO) application bundle, with a focus on the Speed : Harmonization (SPD-HARM) and Queu...

  14. Power test for first prototype LIBO module

    CERN Multimedia

    Laurent Guiraud

    2000-01-01

    The Linac Booster (LIBO) is a prototype machine for producing particle beams for cancer therapy. Hadron therapy techniques are able to reach deep tumours with less damage to surrounding tissue than with conventional radiotherapy.

  15. An Empirical Investigation of Architectural Prototyping

    DEFF Research Database (Denmark)

    Christensen, Henrik Bærbak; Hansen, Klaus Marius

    2010-01-01

    Architectural prototyping is the process of using executable code to investigate stakeholders’ software architecture concerns with respect to a system under development. Previous work has established this as a useful and cost-effective way of exploration and learning of the design space of a system...... and in addressing issues regarding quality attributes, architectural risks, and the problem of knowledge transfer and conformance. However, the actual industrial use of architectural prototyping has not been thoroughly researched so far. In this article, we report from three studies of architectural prototyping...... in practice. First, we report findings from an ethnographic study of practicing software architects. Secondly, we report from a focus group on architectural prototyping involving architects from four companies. And, thirdly, we report from a survey study of 20 practicing software architects and software...

  16. Presentation Trainer Prototype 1.0

    NARCIS (Netherlands)

    Börner, Dirk; Specht, Marcus

    2014-01-01

    This software sketch comprises the first prototype of the presentation trainer. The application uses the Microsoft Kinect sensor and was built using the Processing 1.5.1 development environment. Available under the GNU LGPL licence version 3 or higher.

  17. Gamma tomography apparatus

    International Nuclear Information System (INIS)

    Span, F.J.

    1988-01-01

    The patent concerns a gamma tomography apparatus for medical diagnosis. The apparatus comprises a gamma scintillation camera head and a suspension system for supporting and positioning the camera head with respect for the patient. Both total body scanning and single photon emission tomography can be carried out with the apparatus. (U.K.)

  18. Gamma-sterilization

    International Nuclear Information System (INIS)

    Lindgren, E.

    1974-01-01

    The author makes a survey of his experience in sterilization and sterility control of medical products. At present three different methods are used, steamsterilization, gassterilizing and gammasterilizing. The investments and costs for gamma radiation is presented and a comparison of the costs for gamma- and gassterilization including sterility control is made. (M.S.)

  19. Gamma-ray sources

    International Nuclear Information System (INIS)

    Hermsen, W.

    1980-01-01

    Results are presented from an analysis of the celestial gamma-ray fine-scale structure based on over half of the data which may ultimately be available from the COS-B satellite. A catalogue consisting of 25 gamma-ray sources measured at energies above 100 MeV is presented. (Auth.)

  20. Gamma ray astronomy

    International Nuclear Information System (INIS)

    Hillier, R.

    1984-01-01

    The book reviews the development of gamma ray astronomy over the past twenty five years. A large section of the book is devoted to the problems of background radiation and the design of detectors. Gamma rays from the sun, the galactic disc, the galaxy, and extra galactic sources; are also discussed. (U.K.)

  1. OPAL jet chamber full scale prototype

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, H M; Hauschild, M; Hartmann, H; Hegerath, A; Boerner, H; Burckhart, H J; Dittmar, M; Hammarstroem, R; Heuer, R D; Mazzone, L

    1986-12-01

    The concept of a jet chamber for the central detector of OPAL has been tested with a full scale prototype. The design of this prototype, its mechanical and electrical structure and its support system for high voltage, gas, laser calibration and readout are described. Operating experience has been gathered since summer 1984. The chamber performance in terms of spatial resolution and particle identification capability is given.

  2. OPAL jet chamber full scale prototype

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, H M; Hauschild, M; Hartmann, H; Hegerath, A; Boerner, H; Burckhart, H J; Dittmar, M; Hammarstreom, R; Heuer, R D; Mazzone, L

    1986-05-22

    The concept of a jet chamber for the central detector of OPAL has been tested with a full scale prototype. The design of this prototype, its mechanical and electrical structure and its support system for high voltage, gas, laser calibration and readout are described. The operating experience gathered since the summer of 1984 and the chamber performance as measured by its spatial resolution and ability to identify particles are also given.

  3. Light Guide Collector Prototype: Laboratory Testing

    Directory of Open Access Journals (Sweden)

    Jitka - Mohelnikova

    2017-12-01

    Full Text Available The article reviews the potential of light guide system equipped by a concentrator device capturing daylight applicable for illumination of building interiors and presents results of experiments on performance of its prototype. The main goal is focused on the comparison of traditional solutions and newly developed prototype of the light guide system and presents examination of its light transmission efficiency based on the laboratory experiments.

  4. Light Guide Collector Prototype: Laboratory Testing

    OpenAIRE

    Jitka - Mohelnikova; Stanislav Darula; Ayodeji Omishore; Petr Mohelnik; Denis Micek

    2017-01-01

    The article reviews the potential of light guide system equipped by a concentrator device capturing daylight applicable for illumination of building interiors and presents results of experiments on performance of its prototype. The main goal is focused on the comparison of traditional solutions and newly developed prototype of the light guide system and presents examination of its light transmission efficiency based on the laboratory experiments.

  5. Software testing for evolutionary iterative rapid prototyping

    OpenAIRE

    Davis, Edward V., Jr.

    1990-01-01

    Approved for public release; distribution unlimited. Rapid prototyping is emerging as a promising software development paradigm. It provides a systematic and automatable means of developing a software system under circumstances where initial requirements are not well known or where requirements change frequently during development. To provide high software quality assurance requires sufficient software testing. The unique nature of evolutionary iterative prototyping is not well-suited for ...

  6. Automated prototyping tool-kit (APT)

    OpenAIRE

    Nada, Nader; Shing, M.; Berzins, V.; Luqi

    2002-01-01

    Automated prototyping tool-kit (APT) is an integrated set of software tools that generate source programs directly from real-time requirements. The APT system uses a fifth-generation prototyping language to model the communication structure, timing constraints, 1/0 control, and data buffering that comprise the requirements for an embedded software system. The language supports the specification of hard real-time systems with reusable components from domain specific component libraries. APT ha...

  7. Prototype_Matematikforløb_Sct-Hans

    DEFF Research Database (Denmark)

    Davidsen, Helle Munkholm; Sørensen, Kirsten Bonde; Klitø, Nanna Breinholt

    2015-01-01

    Forløbet udgør en prototype på et matematikforløb til 8. klasse, som er udviklet til at styrke og fastholde elevers motivation for læring. Formålet med denne prototype er at styrke motivationen for læring gennem synlige læringsmål, faglig differentiering og elevernes medbestemmelse. Didaktisk mål...

  8. Prototype_Danskforløb_Sct.Hans

    DEFF Research Database (Denmark)

    Davidsen, Helle Munkholm; Sørensen, Kirsten Bonde; Klitø, Nanna Breinholt

    2015-01-01

    Forløbet udgør en prototype på et danskforløb til 4. klasse, som er udviklet til at styrke og fastholde elevers motivation for læring. Formålet med denne prototype er at styrke motivationen for læring gennem synlige læringsmål, faglig differentiering og elevernes medbestemmelse. Didaktisk mål: at...

  9. Handheld Computing

    National Research Council Canada - National Science Library

    Alford, Kenneth L

    2005-01-01

    .... It outlines some of the considerations involved in a PDA procurement, discusses four tools for developing PDA resource materials -- programming tools, hypertext markup language- and eXtensible markup...

  10. Evolving Consumption Patterns of Various Information Media via Handheld Mobile Devices

    Directory of Open Access Journals (Sweden)

    Nitza Geri

    2015-06-01

    Full Text Available This study examines diverse information media in order to identify those formats that are most suitable for consumption via handheld mobile devices, namely, smartphones and tablets. The preferences of the users are measured objectively by analyzing actual data of their relative use of handheld mobile devices and personal computing (PC desktop devices, including laptops and notebooks, for consumption of information presented in various formats. Our findings are based on Google Analytics pageview data of five course Websites during a period of three semesters, by 11,557 undergraduate students. M-learning contexts were chosen, since in a learning environment the interests of information providers (i.e., the instructors are in accord with those of the information consumers (i.e., the students, whereas in commercial settings there may be conflicts of interests. Our findings demonstrate that although about 90% of the pageviews were via PC devices, the rate of smartphone use for consuming learning content in diverse information media is gradually increasing as time goes by, whereas the rate of tablet use for these purposes is stagnant. The most promising direction for smartphone development, emanating from the findings, is online video content.

  11. Spectral domain, common path OCT in a handheld PIC based system

    Science.gov (United States)

    Leinse, Arne; Wevers, Lennart; Marchenko, Denys; Dekker, Ronald; Heideman, René G.; Ruis, Roosje M.; Faber, Dirk J.; van Leeuwen, Ton G.; Kim, Keun Bae; Kim, Kyungmin

    2018-02-01

    Optical Coherence Tomography (OCT) has made it into the clinic in the last decade with systems based on bulk optical components. The next disruptive step will be the introduction of handheld OCT systems. Photonic Integrated Circuit (PIC) technology is the key enabler for this further miniaturization. PIC technology allows signal processing on a stable platform and the implementation of a common path interferometer in that same platform creates a robust fully integrated OCT system with a flexible fiber probe. In this work the first PIC based handheld and integrated common path based spectral domain OCT system is described and demonstrated. The spectrometer in the system is based on an Arrayed Waveguide Grating (AWG) and fully integrated with the CCD and a fiber probe into a system operating at 850 nm. The AWG on the PIC creates a 512 channel spectrometer with a resolution of 0.22 nm enabling a high speed analysis of the full A-scan. The silicon nitride based proprietary waveguide technology (TriPleXTM) enables low loss complex photonic structures from the visible (405 nm) to IR (2350 nm) range, making it a unique candidate for OCT applications. Broadband AWG operation from visible to 1700 nm has been shown in the platform and Photonic Design Kits (PDK) are available enabling custom made designs in a system level design environment. This allows a low threshold entry for designing new (OCT) designs for a broad wavelength range.

  12. Correlation and Agreement of Handheld Spirometry with Laboratory Spirometry in Allogeneic Hematopoietic Cell Transplant Recipients.

    Science.gov (United States)

    Cheng, Guang-Shing; Campbell, Angela P; Xie, Hu; Stednick, Zach; Callais, Cheryl; Leisenring, Wendy M; Englund, Janet A; Chien, Jason W; Boeckh, Michael

    2016-05-01

    Early detection of subclinical lung function decline may help identify allogeneic hematopoietic cell transplant (HCT) recipients who are at increased risk for late noninfectious pulmonary complications, including bronchiolitis obliterans syndrome. We evaluated the use of handheld spirometry in this population. Allogeneic HCT recipients enrolled in a single-center observational trial performed weekly spirometry with a handheld spirometer for 1 year after transplantation. Participants performed pulmonary function tests in an outpatient laboratory setting at 3 time points: before transplantation, at day 80 after transplantation, and at 1 year after transplantation. Correlation between the 2 methods was assessed by Pearson and Spearman correlations; agreement was assessed using Bland-Altman plots. A total of 437 subjects had evaluable pulmonary function tests. Correlation for forced expiratory volume in 1 second (FEV1) was r = .954 (P spirometry correlated well with laboratory spirometry after allogeneic HCT and may be useful for self-monitoring of patients for early identification of airflow obstruction. Copyright © 2016 American Society for Blood and Marrow Transplantation. All rights reserved.

  13. Strength and Pain Threshold Handheld Dynamometry Test Reliability in Patellofemoral Pain.

    Science.gov (United States)

    van der Heijden, R A; Vollebregt, T; Bierma-Zeinstra, S M A; van Middelkoop, M

    2015-12-01

    Patellofemoral pain syndrome (PFPS), characterized by peri- and retropatellar pain, is a common disorder in young, active people. The etiology is unclear; however, quadriceps strength seems to be a contributing factor, and sensitization might play a role. The study purpose is determining the inter-rater reliability of handheld dynamometry to test both quadriceps strength and pressure pain threshold (PPT), a measure for sensitization, in patients with PFPS. This cross-sectional case-control study comprises 3 quadriceps strength and one PPT measurements performed by 2 independent investigators in 22 PFPS patients and 16 matched controls. Inter-rater reliability was analyzed using intraclass correlation coefficients (ICC) and Bland-Altman plots. Inter-rater reliability of quadriceps strength testing was fair to good in PFPS patients (ICC=0.72) and controls (ICC=0.63). Bland-Altman plots showed an increased difference between assessors when average quadriceps strength values exceeded 250 N. Inter-rater reliability of PPT was excellent in patients (ICC=0.79) and fair to good in controls (ICC=0.52). Handheld dynamometry seems to be a reliable method to test both quadriceps strength and PPT in PFPS patients. Inter-rater reliability was higher in PFPS patients compared to control subjects. With regard to quadriceps testing, a higher variance between assessors occurs when quadriceps strength increases. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Exploring field-of-view non-uniformities produced by a hand-held spectroradiometer

    Directory of Open Access Journals (Sweden)

    Tamir Caras

    2011-01-01

    Full Text Available The shape of a spectroradiometer’s field of view (FOV affects the way spectral measurements are acquired. Knowing this property is a prerequisite for the correct use of the spectrometer. If the substrate is heterogeneous, the ability to accurately know what is being measured depends on knowing the FOV location, shape, spectral and spatial sensitivity. The GER1500 is a hand-held spectrometer with a fixed lens light entry slit and has a laser guide that allows control over the target by positioning the entire unit. In the current study, the FOV of the GER1500 was mapped and analysed. The spectral and spatial non-uniformities of the FOV were examined and were found to be spectrally independent. The relationship between the FOV and the built-in laser guide was tested and found to have a linear displacement dependent on the distance to the target. This allows an accurate prediction of the actual FOV position. A correction method to improve the agreement between the expected and measured reflectance over heterogeneous targets was developed and validated. The methods described are applicable and may be of use with other hand-held spectroradiometers.

  15. Algorithms for a hand-held miniature x-ray fluorescence analytical instrument

    International Nuclear Information System (INIS)

    Elam, W.T.; Newman, D.; Ziemba, F.

    1998-01-01

    The purpose of this joint program was to provide technical assistance with the development of a Miniature X-ray Fluorescence (XRF) Analytical Instrument. This new XRF instrument is designed to overcome the weaknesses of spectrometers commercially available at the present time. Currently available XRF spectrometers (for a complete list see reference 1) convert spectral information to sample composition using the influence coefficients technique or the fundamental parameters method. They require either a standard sample with composition relatively close to the unknown or a detailed knowledge of the sample matrix. They also require a highly-trained operator and the results often depend on the capabilities of the operator. In addition, almost all existing field-portable, hand-held instruments use radioactive sources for excitation. Regulatory limits on such sources restrict them such that they can only provide relatively weak excitation. This limits all current hand-held XRF instruments to poor detection limits and/or long data collection times, in addition to the licensing requirements and disposal problems for radioactive sources. The new XRF instrument was developed jointly by Quantrad Sensor, Inc., the Naval Research Laboratory (NRL), and the Department of Energy (DOE). This report describes the analysis algorithms developed by NRL for the new instrument and the software which embodies them

  16. Handheld pose tracking using vision-inertial sensors with occlusion handling

    Science.gov (United States)

    Li, Juan; Slembrouck, Maarten; Deboeverie, Francis; Bernardos, Ana M.; Besada, Juan A.; Veelaert, Peter; Aghajan, Hamid; Casar, José R.; Philips, Wilfried

    2016-07-01

    Tracking of a handheld device's three-dimensional (3-D) position and orientation is fundamental to various application domains, including augmented reality (AR), virtual reality, and interaction in smart spaces. Existing systems still offer limited performance in terms of accuracy, robustness, computational cost, and ease of deployment. We present a low-cost, accurate, and robust system for handheld pose tracking using fused vision and inertial data. The integration of measurements from embedded accelerometers reduces the number of unknown parameters in the six-degree-of-freedom pose calculation. The proposed system requires two light-emitting diode (LED) markers to be attached to the device, which are tracked by external cameras through a robust algorithm against illumination changes. Three data fusion methods have been proposed, including the triangulation-based stereo-vision system, constraint-based stereo-vision system with occlusion handling, and triangulation-based multivision system. Real-time demonstrations of the proposed system applied to AR and 3-D gaming are also included. The accuracy assessment of the proposed system is carried out by comparing with the data generated by the state-of-the-art commercial motion tracking system OptiTrack. Experimental results show that the proposed system has achieved high accuracy of few centimeters in position estimation and few degrees in orientation estimation.

  17. [Evaluation of accuracy of measuring intraocular pressure by handheld non-contact applanation tonometer].

    Science.gov (United States)

    Chen, X; Peng, D; Zhou, W; Zhong, Y

    1995-06-01

    To evaluate the accuracy of measuring intraocular pressure by handheld non-contact applanation tonometer. 58 patients' (113 eyes) intraocular pressure were measured by Keeler, non-contact tonometer and R 900 Goldmann applanation tonometer and the results of measurement of intraocular pressure by the two kinds of tonometers were compared. The mean intraocular pressure measured by non-contact is 16.31 +/- 5.59 mmHg and 17.49 +/- 6.13 mmHg (1 mmHg = 0.1333 kPa) by Goldmann applanation tonometer, respectively. There was no statistical significance to be found (P > 0.05) between the two methods. By linear correlation and regression analysis, a positive correlation was found between the two methods (r = 0.8942, b = 0.8154). The handheld non-contact tonometer has the same accuracy and reliability of measurement of intraocular pressure comparing with Goldmann applanation tonometer, and it can be used in glaucoma clinic and screening.

  18. Quality-Based Backlight Optimization for Video Playback on Handheld Devices

    Directory of Open Access Journals (Sweden)

    Liang Cheng

    2007-01-01

    Full Text Available For a typical handheld device, the backlight accounts for a significant percentage of the total energy consumption (e.g., around 30% for a Compaq iPAQ 3650. Substantial energy savings can be achieved by dynamically adapting backlight intensity levels on such low-power portable devices. In this paper, we analyze the characteristics of video streaming services and propose a cross-layer optimization scheme called quality adapted backlight scaling (QABS to achieve backlight energy savings for video playback applications on handheld devices. Specifically, we present a fast algorithm to optimize backlight dimming while keeping the degradation in image quality to a minimum so that the overall service quality is close to a specified threshold. Additionally, we propose two effective techniques to prevent frequent backlight switching, which negatively affects user perception of video. Our initial experimental results indicate that the energy used for backlight is significantly reduced, while the desired quality is satisfied. The proposed algorithms can be realized in real time.

  19. Contact lens assisted imaging with integrated flexible handheld probe for glaucoma diagnosis

    Science.gov (United States)

    Hong, Xun Jie Jeesmond; V. K., Shinoj; Murukeshan, V. M.; Baskaran, M.; Aung, Tin

    2017-06-01

    Angle closure glaucoma accounts for majority of the bilateral blindness in Asian countries such as Singapore, China, and India. Abnormalities in the optic nerve and aqueous outflow system are the most indicative clinical hallmarks for glaucoma of this clinical subtype. Traditional photographic imaging techniques to assess the drainage angle are contact based, and may expose patients to risk of corneal abrasion and infections. In addition, these procedures require the use of viscous ophthalmic gels as coupling medium to overcome the phenomenon of total internal reflection at the tear-air interface. In this paper, we propose an integrated flexible handheld probe consisting of a micro color CCD video camera and white light LEDs. The handheld probe is able to capture images of the fundus and opposite iridocorneal angle when placed at the central cornea or limbus respectively. Here, we propose the use of hydrogel contact lens as an index matching medium and better protective barrier, as an alternative to conventional ophthalmic gels. The proposed imaging system and methodology has been successfully tested on porcine eye samples, ex vivo. With its high repeatability, reproducibility, and a good safety profile, it is believed that the proposed imaging system and methodology will complement existing imaging modalities in the diagnosis and management of glaucoma.

  20. A handheld open-field infant keratometer (an american ophthalmological society thesis).

    Science.gov (United States)

    Miller, Joseph M

    2010-12-01

    To design and evaluate a new infant keratometer that incorporates an unobstructed view of the infant with both eyes (open-field design). The design of the open-field infant keratometer is presented, and details of its construction are given. The design incorporates a single-ring keratoscope for measurement of corneal astigmatism over a 4-mm region of the cornea and includes a rectangular grid target concentric within the ring to allow for the study of higher-order aberrations of the eye. In order to calibrate the lens and imaging system, a novel telecentric test object was constructed and used. The system was bench calibrated against steel ball bearings of known dimensions and evaluated for accuracy while being used in handheld mode in a group of 16 adult cooperative subjects. It was then evaluated for testability in a group of 10 infants and toddlers. Results indicate that while the device achieved the goal of creating an open-field instrument containing a single-ring keratoscope with a concentric grid array for the study of higher-order aberrations, additional work is required to establish better control of the vertex distance. The handheld open-field infant keratometer demonstrates testability suitable for the study of infant corneal astigmatism. Use of collimated light sources in future iterations of the design must be incorporated in order to achieve the accuracy required for clinical investigation.